In-situ continuous water monitoring system
Thompson, Cyril V.; Wise, Marcus B.
1998-01-01
An in-situ continuous liquid monitoring system for continuously analyzing volatile components contained in a water source comprises: a carrier gas supply, an extraction container and a mass spectrometer. The carrier gas supply continuously supplies the carrier gas to the extraction container and is mixed with a water sample that is continuously drawn into the extraction container by the flow of carrier gas into the liquid directing device. The carrier gas continuously extracts the volatile components out of the water sample. The water sample is returned to the water source after the volatile components are extracted from it. The extracted volatile components and the carrier gas are delivered continuously to the mass spectrometer and the volatile components are continuously analyzed by the mass spectrometer.
In-situ continuous water monitoring system
Thompson, C.V.; Wise, M.B.
1998-03-31
An in-situ continuous liquid monitoring system for continuously analyzing volatile components contained in a water source comprises: a carrier gas supply, an extraction container and a mass spectrometer. The carrier gas supply continuously supplies the carrier gas to the extraction container and is mixed with a water sample that is continuously drawn into the extraction container by the flow of carrier gas into the liquid directing device. The carrier gas continuously extracts the volatile components out of the water sample. The water sample is returned to the water source after the volatile components are extracted from it. The extracted volatile components and the carrier gas are delivered continuously to the mass spectrometer and the volatile components are continuously analyzed by the mass spectrometer. 2 figs.
Trace Gas Analyzer (TGA) program
NASA Technical Reports Server (NTRS)
1977-01-01
The design, fabrication, and test of a breadboard trace gas analyzer (TGA) is documented. The TGA is a gas chromatograph/mass spectrometer system. The gas chromatograph subsystem employs a recirculating hydrogen carrier gas. The recirculation feature minimizes the requirement for transport and storage of large volumes of carrier gas during a mission. The silver-palladium hydrogen separator which permits the removal of the carrier gas and its reuse also decreases vacuum requirements for the mass spectrometer since the mass spectrometer vacuum system need handle only the very low sample pressure, not sample plus carrier. System performance was evaluated with a representative group of compounds.
Method and apparatus for generating motor current spectra to enhance motor system fault detection
Linehan, Daniel J.; Bunch, Stanley L.; Lyster, Carl T.
1995-01-01
A method and circuitry for sampling periodic amplitude modulations in a nonstationary periodic carrier wave to determine frequencies in the amplitude modulations. The method and circuit are described in terms of an improved motor current signature analysis. The method insures that the sampled data set contains an exact whole number of carrier wave cycles by defining the rate at which samples of motor current data are collected. The circuitry insures that a sampled data set containing stationary carrier waves is recreated from the analog motor current signal containing nonstationary carrier waves by conditioning the actual sampling rate to adjust with the frequency variations in the carrier wave. After the sampled data is transformed to the frequency domain via the Discrete Fourier Transform, the frequency distribution in the discrete spectra of those components due to the carrier wave and its harmonics will be minimized so that signals of interest are more easily analyzed.
Performance Characterization of RaPToRS Systems
NASA Astrophysics Data System (ADS)
Shibata, K.; Krieger, M.; Fallica, J.; Henchen, R.; Pogozelski, E.; Padalino, S.; SUNY Geneseo Collaboration; LaboratoryLaser Energetics at University of Rochester Collaboration
2011-10-01
The Rapid Pneumatic Transport of Radioactive Samples (RaPToRS) system can quickly and efficiently move radioactive materials from their activation site to a counting station. Facilities such as the NIF and LLE are considering these systems while NRL is currently using one. The system is essentially a 10 cm diameter pneumatic tube with a cylindrical sample carrier. The performance of the system depends on many factors, including the mass of the carrier, length of the tube, angle and difference in height of the tube's endpoints, the carrier's physical design, and the number, type, and distribution of blowers attached to the tube. These factors have been systematically examined to develop the fastest and most reliable system. The most significant factors are the mass and the vertical travel of the carrier. When the carrier mass is low, moving air supports the carrier in the tube, resulting in low friction. The terminal velocity ranges from 13.5 to 2.5 m/s for masses varying from 1 kg to 3 kg. Using a single 1100 W blower, the initial force exerted on the carrier was 11.3 N. This work was supported in part by the US Department of Energy through the LLE.
Mariella, Jr., Raymond P.
2018-03-06
An isotachophoresis system for separating a sample containing particles into discrete packets including a flow channel, the flow channel having a large diameter section and a small diameter section; a negative electrode operably connected to the flow channel; a positive electrode operably connected to the flow channel; a leading carrier fluid in the flow channel; a trailing carrier fluid in the flow channel; and a control for separating the particles in the sample into discrete packets using the leading carrier fluid, the trailing carrier fluid, the large diameter section, and the small diameter section.
In-situ continuous water analyzing module
Thompson, Cyril V.; Wise, Marcus B.
1998-01-01
An in-situ continuous liquid analyzing system for continuously analyzing volatile components contained in a water source comprises: a carrier gas supply, an extraction container and a mass spectrometer. The carrier gas supply continuously supplies the carrier gas to the extraction container and is mixed with a water sample that is continuously drawn into the extraction container. The carrier gas continuously extracts the volatile components out of the water sample. The water sample is returned to the water source after the volatile components are extracted from it. The extracted volatile components and the carrier gas are delivered continuously to the mass spectometer and the volatile components are continuously analyzed by the mass spectrometer.
Method and apparatus for generating motor current spectra to enhance motor system fault detection
Linehan, D.J.; Bunch, S.L.; Lyster, C.T.
1995-10-24
A method and circuitry are disclosed for sampling periodic amplitude modulations in a nonstationary periodic carrier wave to determine frequencies in the amplitude modulations. The method and circuit are described in terms of an improved motor current signature analysis. The method insures that the sampled data set contains an exact whole number of carrier wave cycles by defining the rate at which samples of motor current data are collected. The circuitry insures that a sampled data set containing stationary carrier waves is recreated from the analog motor current signal containing nonstationary carrier waves by conditioning the actual sampling rate to adjust with the frequency variations in the carrier wave. After the sampled data is transformed to the frequency domain via the Discrete Fourier Transform, the frequency distribution in the discrete spectra of those components due to the carrier wave and its harmonics will be minimized so that signals of interest are more easily analyzed. 29 figs.
NASA Astrophysics Data System (ADS)
Henchen, Robert; Esham, Benjamin; Becker, William; Pogozelski, Edward; Padalino, Stephen; Sangster, Thomas; Glebov, Vladimir
2008-11-01
The High-Speed Rapid Pneumatic Transport of Radioactive Samples (HS-RaPToRS) system, designed to quickly and safely move radioactive materials, was assembled and tested at the Mercury facility of the Naval Research Laboratory (NRL) in Washington D.C. A sample, which is placed inside a four-inch-diameter carrier, is activated before being transported through a PVC tube via airflow. The carrier travels from the reaction chamber to the end station where it pneumatically brakes prior to the gate. A magnetic latch releases the gate when the carrier arrives and comes to rest. The airflow, optical carrier-monitoring devices, and end gate are controlled manually or automatically with LabView software. The installation and testing of the RaPToRS system at NRL was successfully completed with transport times of less than 3 seconds. The speed of the carrier averaged 16 m/s. Prospective facilities for similar systems include the Laboratory for Laser Energetics and the National Ignition Facility.
Situ soil sampling probe system with heated transfer line
Robbat, Jr., Albert
2002-01-01
The present invention is directed both to an improved in situ penetrometer probe and to a heated, flexible transfer line. The line and probe may be implemented together in a penetrometer system in which the transfer line is used to connect the probe to a collector/analyzer at the surface. The probe comprises a heater that controls a temperature of a geologic medium surrounding the probe. At least one carrier gas port and vapor collection port are located on an external side wall of the probe. The carrier gas port provides a carrier gas into the geologic medium, and the collection port captures vapors from the geologic medium for analysis. In the transfer line, a flexible collection line that conveys a collected fluid, i.e., vapor, sample to a collector/analyzer. A flexible carrier gas line conveys a carrier gas to facilitate the collection of the sample. A system heating the collection line is also provided. Preferably the collection line is electrically conductive so that an electrical power source can generate a current through it so that the internal resistance generates heat.
NASA Astrophysics Data System (ADS)
Lundgren, J.; Esham, B.; Padalino, S. J.; Sangster, T. C.; Glebov, V.
2007-11-01
The Venting and Exhausting of Low Level Air Contaminants in the Rapid Pneumatic Transport of Radioactive Samples (VELoCiRaPTORS) system is constructed to transport radioactive materials quickly and safely at the NIF. A radioactive sample will be placed inside a carrier that is transported via an airflow system produced by controlled differential pressure. Midway through the transportation process, the carrier will be stopped and vented by a powered exhaust blower which will remove radioactive gases within the transport carrier. A Geiger counter will monitor the activity of the exhaust gas to ensure that it is below acceptable levels. If the radiation level is sufficient, the carrier will pass through the remainder of the system, pneumatically braking at the counting station. The complete design will run manually or automatically with control software. Tests were performed using an inactive carrier to determine possible transportation problems. The system underwent many consecutive trials without failure. VELoCiRaPTORS is a prototype of a system that could be installed at both the Laboratory for Laser Energetics at the University of Rochester and the National Ignition Facility at LLNL.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Papadogianni, Alexandra; Bierwagen, Oliver; White, Mark E.
2015-12-21
We propose a simple method based on the combination of Hall and Seebeck measurements to estimate the thickness of a carrier system within a semiconductor film. As an example, this method can distinguish “bulk” carriers, with homogeneous depth distribution, from “sheet” carriers, that are accumulated within a thin layer. The thickness of the carrier system is calculated as the ratio of the integral sheet carrier concentration, extracted from Hall measurements, to the volume carrier concentration, derived from the measured Seebeck coefficient of the same sample. For rutile SnO{sub 2}, the necessary relation of Seebeck coefficient to volume electron concentration inmore » the range of 3 × 10{sup 17} to 3 × 10{sup 20 }cm{sup −3} has been experimentally obtained from a set of single crystalline thin films doped with varying Sb-doping concentrations and unintentionally doped bulk samples, and is given as a “calibration curve.” Using this calibration curve, our method demonstrates the presence of interface electrons in homogeneously deep-acceptor (In) doped SnO{sub 2} films on sapphire substrates.« less
Laser heating of aqueous samples on a micro-optical-electro-mechanical system
Beer, Neil Reginald; Kennedy, Ian
2013-12-17
A system of heating a sample on a microchip includes the steps of providing a microchannel flow channel in the microchip; positioning the sample within the microchannel flow channel, providing a laser that directs a laser beam onto the sample for heating the sample; providing the microchannel flow channel with a wall section that receives the laser beam and enables the laser beam to pass through wall section of the microchannel flow channel without being appreciably heated by the laser beam; and providing a carrier fluid in the microchannel flow channel that moves the sample in the microchannel flow channel wherein the carrier fluid is not appreciably heated by the laser beam.
Laser heating of aqueous samples on a micro-optical-electro-mechanical system
Beer, Neil Reginald; Kennedy, Ian
2013-02-05
A system of heating a sample on a microchip includes the steps of providing a microchannel flow channel in the microchip; positioning the sample within the microchannel flow channel, providing a laser that directs a laser beam onto the sample for heating the sample; providing the microchannel flow channel with a wall section that receives the laser beam and enables the laser beam to pass through wall section of the microchannel flow channel without being appreciably heated by the laser beam; and providing a carrier fluid in the microchannel flow channel that moves the sample in the microchannel flow channel wherein the carrier fluid is not appreciably heated by the laser beam.
Demodulator for carrier transducers
NASA Technical Reports Server (NTRS)
Roller, R. F. (Inventor)
1974-01-01
A carrier type transducer is supplied with a carrier wave via an audio amplifier, a filter, a frequency divider, and an oscillator. The carrier is modulated in accordance with the parameter being measured by the transducer and is fed to the input of a digital data system which may include a voltmeter. The output of the oscillator and the output of each stage of the divider are fed to an AND or a NAND gate and suitable variable and fixed delay circuits to the command input of the digital data system. With this arrangement, the digital data system is commanded to sample at the proper time so that the average voltage of the modulated carrier is measured. It may be utilized with ancillary circuitry for control of the parameter
NASA Astrophysics Data System (ADS)
Anand, Vikas; Singh, K. J.; Kaur, Kulwinder; Bhatia, Gaurav
2016-05-01
Magnetically attracted MnFe2O4 and CoFe2O4 doped hydroxylapatite samples have been prepared by using co-precipitation method in the laboratory. Bioactive nature of samples has been confirmed from XRD spectra. Ferromagnetic behavior of samples has been studied by using vibration sample magnetometer. Human osteoblast cell line MG63 has been used to explore the cell viability of samples. Drug carrier ability of samples has been checked with gentamycin as an antibiotic and results show that samples can be used as excellent drug carriers. Drug loaded samples can be easily targeted to specific area due to their attractive nature towards external magnetic field. Our results indicate that prepared samples possess good bioactive as well as ferromagnetic behavior with drug carrier ability and hence, our samples can be potential candidates for the clinical applications.
Laser heating of aqueous samples on a micro-optical-electro-mechanical system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beer, Neil Reginald; Kennedy, Ian
2013-12-17
A system of heating a sample on a microchip includes the steps of providing a microchannel flow channel in the microchip; positioning the sample within the microchannel flow channel, providing a laser that directs a laser beam onto the sample for heating the sample; providing the microchannel flow channel with a wall section that receives the laser beam and enables the laser beam to pass through wall section of the microchannel flow channel without being appreciably heated by the laser beam; and providing a carrier fluid in the microchannel flow channel that moves the sample in the microchannel flow channelmore » wherein the carrier fluid is not appreciably heated by the laser beam.« less
Spectroscopy of Photovoltaic Materials: Charge-Transfer Complexes and Titanium Dioxide
NASA Astrophysics Data System (ADS)
Dillon, Robert John
The successful function of photovoltaic (PV) and photocatalytic (PC) systems centers primarily on the creation and photophysics of charge separated electron-hole pairs. The pathway leading to separate carriers varies by material; organic materials typically require multiple events to charge separate, whereas inorganic semiconductors can directly produce free carriers. In this study, time-resolved spectroscopy is used to provide insight into two such systems: 1) organic charge-transfer (CT) complexes, where electrons and holes are tightly bound to each other, and 2) Au-TiO2 core-shell nanostructures, where free carriers are directly generated. 1) CT complexes are structurally well defined systems consisting of donor molecules, characterized by having low ionization potentials, and acceptor molecules, characterized by having high electron affinities. Charge-transfer is the excitation of an electron from the HOMO of a donor material directly into the LUMO of the acceptor material, leading to an electron and hole separated across the donor:acceptor interface. The energy of the CT transition is often less than that of the bandgaps of donor and acceptor materials individually, sparking much interest if PV systems can utilize the CT band to generate free carriers from low energy photons. In this work we examine the complexes formed between acceptors tetracyanobenzene (TCNB) and tetracyanoquinodimethane (TCNQ) with several aromatic donors. We find excitation of the charge-transfer band of these systems leads to strongly bound electron-hole pairs that exclusively undergo recombination to the ground state. In the case of the TCNB complexes, our initial studies were flummoxed by the samples' generally low threshold for photo and mechanical damage. As our results conflicted with previous literature, a significant portion of this study was spent quantifying the photodegradation process. 2) Unlike the previous system, free carriers are directly photogenerated in TiO2, and the prime consideration is avoiding loss due to recombination of the electron and hole. In this study, four samples of core-shell Au-TiO 2 nanostructures are analyzed for their photocatalytic activity and spectroscopic properties. The samples were made with increasingly crystalline TiO2 shells. The more crystalline samples had higher photocatalytic activities, attributed to longer carrier lifetimes. The observed photophysics of these samples vary with excitation wavelength and detection method used. We find the time-resolved photoluminescence correlates with the samples' photocatalytic activities only when high energy, excitation wavelength less than or equal to 300 nm is used, while transient absorption experiments show no correlation regardless of excitation source. The results imply that photoexcitation with high energy photons can generate both reactive surface sites and photoluminescent surface sites in parallel. Both types of sites then undergo similar electron-hole recombination processes that depend on the crystallinity of the TiO2 shell. Surface sites created by low energy photons, as well as bulk TiO2 carrier dynamics that are probed by transient absorption, do not appear to be sensitive to the same dynamics that determine chemical reactivity.
NASA Astrophysics Data System (ADS)
Chen, Xiangyu; Taguchi, Dai; Manaka, Takaaki; Iwamoto, Mitsumasa
2016-02-01
By using optical electric-field-induced second-harmonic generation (EFISHG) technique, we studied carrier behavior caused by contact electrification (CE) in an organic double-layer element. This double-layer sample was half suspended in the open air, where one electrode (anode or cathode) was connected with a Cu foil for electrification while the other electrode was floated. Results showed two distinct carrier behaviors, depending on the (anode or cathode) connections to the Cu foil, and these carrier behaviors were analyzed based on the Maxwell-Wagner model. The double-layer sample works as a simple solar cell device. The photovoltaic effect and CE process have been proved to be two paralleled effects without strong interaction with each other, while photoconductivity changing in the sample can enhance the relaxation of CE induced charges. By probing the carrier behavior in this half-suspended device, the EFISHG technique has been demonstrated to be an effective non-contact method for clarifying the CE effect on related energy harvesting devices and electronics devices. Meanwhile, the related physical analysis in this letter is also useful for elucidating the fundamental characteristic of hybrid energy system based on solar cell and triboelectric nanogenerator.
NASA Astrophysics Data System (ADS)
Meng, Xiao; Wang, Lai; Hao, Zhibiao; Luo, Yi; Sun, Changzheng; Han, Yanjun; Xiong, Bing; Wang, Jian; Li, Hongtao
2016-01-01
Efficiency droop is currently one of the most popular research problems for GaN-based light-emitting diodes (LEDs). In this work, a differential carrier lifetime measurement system is optimized to accurately determine carrier lifetimes (τ) of blue and green LEDs under different injection current (I). By fitting the τ-I curves and the efficiency droop curves of the LEDs according to the ABC carrier rate equation model, the impact of Auger recombination and carrier leakage on efficiency droop can be characterized simultaneously. For the samples used in this work, it is found that the experimental τ-I curves cannot be described by Auger recombination alone. Instead, satisfactory fitting results are obtained by taking both carrier leakage and carriers delocalization into account, which implies carrier leakage plays a more significant role in efficiency droop at high injection level.
Testing of a Microfluidic Sampling System for High Temperature Electrochemical MC&A
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pereira, Candido; Nichols, Kevin
2013-11-27
This report describes the preliminary validation of a high-temperature microfluidic chip system for sampling of electrochemical process salt. Electroanalytical and spectroscopic techniques are attractive candidates for improvement through high-throughput sample analysis via miniaturization. Further, microfluidic chip systems are amenable to micro-scale chemical processing such as rapid, automated sample purification to improve sensor performance. The microfluidic chip was tested to determine the feasibility of the system for high temperature applications and conditions under which microfluidic systems can be used to generate salt droplets at process temperature to support development of material balance and control systems in a used fuel treatment facility.more » In FY13, the project focused on testing a quartz microchip device with molten salts at near process temperatures. The equipment was installed in glove box and tested up to 400°C using commercial thermal transfer fluids as the carrier phase. Preliminary tests were carried out with a low-melting halide salt to initially characterize the properties of this novel liquid-liquid system and to investigate the operating regimes for inducing droplet flow within candidate carrier fluids. Initial results show that the concept is viable for high temperature sampling but further development is required to optimize the system to operate with process relevant molten salts.« less
Luo, Yong; Wu, Wenqi; Babu, Ravindra; Tang, Kanghua; Luo, Bing
2012-01-01
COMPASS is an indigenously developed Chinese global navigation satellite system and will share many features in common with GPS (Global Positioning System). Since the ultra-tight GPS/INS (Inertial Navigation System) integration shows its advantage over independent GPS receivers in many scenarios, the federated ultra-tight COMPASS/INS integration has been investigated in this paper, particularly, by proposing a simplified prefilter model. Compared with a traditional prefilter model, the state space of this simplified system contains only carrier phase, carrier frequency and carrier frequency rate tracking errors. A two-quadrant arctangent discriminator output is used as a measurement. Since the code tracking error related parameters were excluded from the state space of traditional prefilter models, the code/carrier divergence would destroy the carrier tracking process, and therefore an adaptive Kalman filter algorithm tuning process noise covariance matrix based on state correction sequence was incorporated to compensate for the divergence. The federated ultra-tight COMPASS/INS integration was implemented with a hardware COMPASS intermediate frequency (IF), and INS's accelerometers and gyroscopes signal sampling system. Field and simulation test results showed almost similar tracking and navigation performances for both the traditional prefilter model and the proposed system; however, the latter largely decreased the computational load. PMID:23012564
33. DETAILS OF SAMPLE SUPPORT FRAME ASSEMLBY, LIFTING LUG, AND ...
33. DETAILS OF SAMPLE SUPPORT FRAME ASSEMLBY, LIFTING LUG, AND SAMPLE CARRIER ROD. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-S-5. INEL INDEX CODE NUMBER: 075 0701 60 851 151979. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
A high-mobility electronic system at an electrolyte-gated oxide surface
Gallagher, Patrick; Lee, Menyoung; Petach, Trevor A.; ...
2015-03-12
Electrolyte gating is a powerful technique for accumulating large carrier densities at a surface. Yet this approach suffers from significant sources of disorder: electrochemical reactions can damage or alter the sample, and the ions of the electrolyte and various dissolved contaminants sit Angstroms from the electron system. Accordingly, electrolyte gating is well suited to studies of superconductivity and other phenomena robust to disorder, but of limited use when reactions or disorder must be avoided. Here we demonstrate that these limitations can be overcome by protecting the sample with a chemically inert, atomically smooth sheet of hexagonal boron nitride. We illustratemore » our technique with electrolyte-gated strontium titanate, whose mobility when protected with boron nitride improves more than 10-fold while achieving carrier densities nearing 10 14 cm –2. In conclusion, our technique is portable to other materials, and should enable future studies where high carrier density modulation is required but electrochemical reactions and surface disorder must be minimized.« less
Chehade, Rania; Pettapiece-Phillips, Rachael; Salmena, Leonardo; Kotlyar, Max; Jurisica, Igor; Narod, Steven A; Akbari, Mohammad R; Kotsopoulos, Joanne
2016-08-17
BRCA1 mutation carriers face a high lifetime risk of developing both breast and ovarian cancer. Haploinsufficiency is thought to predispose these women to cancer by reducing the pool of available BRCA1 transcript and protein, thereby compromising BRCA1 function. Whether or not cancer-free BRCA1 mutation carriers have lower messenger (m)RNA transcript levels in peripheral blood leukocytes has not been evaluated. The primary aim of this study was to characterize an association between BRCA1 mutation status and BRCA1 mRNA leukocyte expression levels among healthy women with a BRCA1 mutation. RNA was extracted from freshly isolated peripheral blood leukocytes of 58 cancer-free, female participants (22 BRCA1 mutation carriers and 36 non-carriers). The expression levels of 236 cancer-associated genes, including BRCA1, were quantified using the Human Cancer Reference gene panel from the Nanostring Technologies nCounter Analysis System. Multivariate modeling demonstrated that carrying a BRCA1 mutation was the most significant predictor of BRCA1 mRNA levels. BRCA1 mRNA levels were significantly lower in BRCA1 mutation carriers compared to non-carriers (146.7 counts vs. 175.1 counts; P = 0.002). Samples with BRCA1 mutations within exon 11 had lower BRCA1 mRNA levels than samples with mutations within the 5' and 3' regions of the BRCA1 gene (122.1 counts vs. 138.9 and 168.6 counts, respectively; P = 0.003). Unsupervised hierarchical clustering of gene expression profiles from freshly isolated blood leukocytes revealed that BRCA1 mutation carriers cluster more closely with other BRCA1 mutation carriers than with BRCA1 wild-type samples. Moreover, a set of 17 genes (including BRCA1) previously shown to be involved in carcinogenesis, were differentially expressed between BRCA1 mutation carriers and non-carriers. Overall, these findings support the concept of BRCA1 haploinsufficiency wherein a specific mutation results in dosage-dependent alteration of BRCA1 at the transcriptional level. This study is the first to show a decrease in BRCA1 mRNA expression in freshly isolated blood leukocytes from healthy, unaffected BRCA1 mutation carriers.
40 CFR 141.804 - Aircraft water system operations and maintenance plan.
Code of Federal Regulations, 2013 CFR
2013-07-01
... must include the following requirements for procedures for disinfection and flushing of aircraft water system. (i) The air carrier must conduct disinfection and flushing of the aircraft water system in... water procedures; (ii) Sample collection procedures; (iii) Disinfection and flushing procedures; (iv...
Development of megasonic cleaning for silicon wafers
NASA Technical Reports Server (NTRS)
Mayer, A.
1980-01-01
A cleaning and drying system for processing at least 2500 three in. diameter wafers per hour was developed with a reduction in process cost. The system consists of an ammonia hydrogen peroxide bath in which both surfaces of 3/32 in. spaced, ion implanted wafers are cleaned in quartz carriers moved on a belt past two pairs of megasonic transducers. The wafers are dried in the novel room temperature, high velocity air dryer in the same carriers used for annealing. A new laser scanner was used effectively to monitor the cleaning ability on a sampling basis.
Full-field optical coherence tomography used for security and document identity
NASA Astrophysics Data System (ADS)
Chang, Shoude; Mao, Youxin; Sherif, Sherif; Flueraru, Costel
2006-09-01
The optical coherence tomography (OCT) is an emerging technology for high-resolution cross-sectional imaging of 3D structures. In the past years, OCT systems have been used mainly for medical, especially ophthalmological diagnostics. Concerning the nature of OCT system being capable to explore the internal features of an object, we apply the OCT technology to directly retrieve the 2D information pre-stored in a multiple-layer information carrier. The standard depth-resolution of an OCT system is at micrometer level. If a 20mm by 20mm sampling area with a 1024 x 1024 CCD array is used in the OCT system having 10 μm, an information carrier having a volume of 20mm x 20mm x 2mm could contain 200 Mega-pixel images. Because of its tiny size and large information volume, the information carrier, with its OCT retrieving system, will have potential applications in documents security and object identification. In addition, as the information carrier can be made by low-scattering transparent material, the signal/noise ratio will be improved dramatically. As a consequence, the specific hardware and complicated software can also be greatly simplified. Owing to non-scanning along X-Y axis, the full-field OCT could be the simplest and most economic imaging system for extracting information from such a multilayer information carrier. In this paper, deign and implementation of a full-field OCT system is described and the related algorithms are introduced. In our experiments, a four layers information carrier is used, which contains 4 layers of image pattern, two text images and two fingerprint images. The extracted tomography images of each layer are also provided.
DEMONSTRATION BULLETIN: HNU-HANBY PCP IMMUNOASSAY TEST KIT - HNU - SYSTEMS, INC.
The HNU-Hanby test kit rapidly analyzes for petroleum hydrocarbons in soil and water samples. The test kit can be used to estimate pentachlorophenol (PCP) concentrations in samples when the carrier solvent is a petroleum hydrocarbon. The test kit estimates PCP concentrations in ...
Density variations of plastic carriers in metallic glasses during aging
NASA Astrophysics Data System (ADS)
Fan, Yue; Iwashita, Takuya; Egami, Takeshi
Thermally induced deformation in metallic glasses was investigated by sampling the potential energy landscape (PEL) and probing the changes in the atomic properties (e.g. energy, displacement, stress). We demonstrate that there exists a universal plastic carrier in amorphous materials, which corresponds to the hopping between local minima on PEL. However very interestingly, the density of plastic carrier is largely affected by the aging history of the glasses. The higher fictive temperature (i . e . fast cooling rate), the larger density of plastic carrier is contained in the system. In particular, we observe a scaling of ρ~exp(- α/Tfic) , which is consistent with the prediction of shear transformation zone theory. The work is supported by U.S. Department of Energy.
Jiao, Shuliang; Todorović, Milos; Stoica, George; Wang, Lihong V
2005-09-10
We report on a new configuration of fiber-based polarization-sensitive Mueller matrix optical coherence tomography that permits the acquisition of the round-trip Jones matrix of a biological sample using only one light source and a single depth scan. In this new configuration, a polarization modulator is used in the source arm to continuously modulate the incident polarization state for both the reference and the sample arms. The Jones matrix of the sample can be calculated from the two frequency terms in the two detection channels. The first term is modulated by the carrier frequency, which is determined by the longitudinal scanning mechanism, whereas the other term is modulated by the beat frequency between the carrier frequency and the second harmonic of the modulation frequency of the polarization modulator. One important feature of this system is that, for the first time to our knowledge, the Jones matrix of the sample can be calculated with a single detection channel and a single measurement when diattenuation is negligible. The system was successfully tested by imaging both standard polarization elements and biological samples.
A gas sampling system for withdrawing humid gases from deep boreholes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rousseau, J.P.; Thordarson, W.; Kurzmack, M.A.
A gas sampling system, designed to withdraw nearly vapor-saturated gases (93 to 100% relative humidity) from deep, unsaturated zone boreholes, was developed by the U.S. Geological Survey for use in the unsaturated zone borehole instrumentation and monitoring program at Yucca Mountain, Nye County, Nevada. This gas sampling system will be used to: (1) sample formation rock gases in support of the unsaturated zone hydrochemical characterization program; and (2) verify downhole, thermocouple psychrometer measurements of water potential in support of the unsaturated zone borehole instrumentation and monitoring program. Using this sampling system, nearly vapor-saturated formation rock-gases can be withdrawn from deepmore » boreholes without condensing water vapor in the sampling tubes, and fractionating heavy isotopes of oxygen, hydrogen, and carbon. The sampling system described in this paper uses a dry carrier-gas (nitrogen) to lower the dew point temperature of the formation rock-gas at its source. Mixing of the dry carrier gas with the source gas takes place inside a specially designed downhole instrument station apparatus (DISA). Nitrogen inflow is regulated in a manner that lowers the dew point temperature of the source gas to a temperature that is colder than the coldest temperature that the mixed gas will experience in moving from warmer, deeper depths, to colder, shallower depths near the land surface. A test of this gas sampling system was conducted in December, 1992, in a 12.2 meter deep borehole that was instrumented in October, 1991. The water potential calculated using this system reproduced in-situ measurements of water potential to within five percent of the average value, as recorded by two thermocouple psychrometers that had been in operation for over 12 months.« less
Effectiveness of Sunscreen at Preventing Solar UV-Induced Alterations of Human Stratum Corneum
NASA Astrophysics Data System (ADS)
Martinez, O.; Dauskardt, R.; Biniek, K.; Novoa, F.
2012-12-01
The outermost layer of the epidermis, the stratum corneum, protects the body from harmful environmental conditions by serving as a selective barrier. Solar ultraviolet (UV) radiation is one of the most common conditions the body encounters and is responsible for many negative skin responses, including compromised barrier function. UV exposure has dramatic effects on stratum corneum cell cohesion and mechanical integrity that are related to its effects on the stratum corneum's intercellular lipids. Hypothesis Sunscreen contains chemicals that absorb UV radiation to prevent the radiation from penetrating the skin. Thus, it is expected that the application of sunscreen on human stratum corneum will reduce UV-induced alterations of human stratum corneum. Procedures/Equipment Human tissue was processed in order to isolate the stratum corneum, the top layer of the epidermis. Double cantilever beam (DCB) testing was used to study the effect of UV radiation on human stratum corneum. Two different types of DCB samples were created: control DCB samples with the application of carrier and UV light to the stratum corneum and DCB samples with the application of sunscreen and UV light to the stratum corneum. For the control sample, one side of the stratum corneum was glued to a polycarbonate beam and carrier was applied. Then, the sample was placed 10 cm away from the UV lamp inside of the environmental chamber and were exposed to UV dosages of about 800 J/cm2. Once this step was complete, a second polycarbonate beam was glued to the other side of the stratum corneum. The steps were similar for the DCB sample that had sunscreen applied and that was exposed to UV light. After gluing one side of the stratum corneum to a polycarbonate beam, Octinoxate sunscreen was applied. The next steps were similar to those of the control sample. All DCB samples were then let out to dry for two hours in a dry box in order for the moisture from the lab to be extracted. Each DCB sample was tested with a Delaminator test system (DTS Company). The Delaminator was used to measure the force required to break the bonds between the Stratum Corneum lipid layers. Delamination energies, Gc, were presented as mean values ± 1.96 x the standard error of the mean (STDEM) in which the mean values reported are expected to fall within these bounds with 95% confidence. Results The samples for the UV exposed carrier and Octinoxate samples were tested. Various samples were used to compare the average delamination energy in order to fulfill the 95% confidence level. The delamination energy was lower for the carrier samples than for the Octinoxate samples. The average Gc value for the carrier samples was 5, and the average Gc value for the Octinoxate samples was 7. Conclusion In response to the averaging lower Gc value for the carrier, it is evident that sunscreen does protect the stratum corneum's mechanical properties. It took higher delamination energy to break apart the lipids in the sunscreen sample than it did for the carrier sample. Therefore, the sunscreen helps the stratum corneum contain its intercellular cohesion.
A large-scale cryoelectronic system for biological sample banking
NASA Astrophysics Data System (ADS)
Shirley, Stephen G.; Durst, Christopher H. P.; Fuchs, Christian C.; Zimmermann, Heiko; Ihmig, Frank R.
2009-11-01
We describe a polymorphic electronic infrastructure for managing biological samples stored over liquid nitrogen. As part of this system we have developed new cryocontainers and carrier plates attached to Flash memory chips to have a redundant and portable set of data at each sample. Our experimental investigations show that basic Flash operation and endurance is adequate for the application down to liquid nitrogen temperatures. This identification technology can provide the best sample identification, documentation and tracking that brings added value to each sample. The first application of the system is in a worldwide collaborative research towards the production of an AIDS vaccine. The functionality and versatility of the system can lead to an essential optimization of sample and data exchange for global clinical studies.
Leal, L O; Elsholz, O; Forteza, R; Cerdà, V
2006-07-28
A new software-controlled time-based multisyringe flow injection system for mercury determination by cold-vapor atomic absorption spectrometry is proposed. Precise known volumes of sample, reducing agent (1.1% SnCl2 in 3% HCl) and carrier (3% HCl) are dispensed into a gas-liquid separation cell with a multisyringe burette coupled with one three-way solenoid valve. An argon flow delivers the reduced mercury to the spectrometer. The optimization of the system was carried out testing reaction coils and gas-liquid separators of different design as well as changing parameters, such as sample and reagents volumes, reagent concentrations and carrier gas flow rate, among others. The analytical curves were obtained within the range 50-5000 ng L(-1). The detection limit (3sigma(b)/S) achieved is 5 ng L(-1). The relative standard deviation (R.S.D.) was 1.4%, evaluated from 16 successive injections of 250 ng L(-1) Hg standard solution. The injection and sample throughput per hour were 44 and 11, respectively. This technique was validated by means of solid and water reference materials with good agreement with the certified values and was successfully applied to fish samples.
Impact of doping on the carrier dynamics in graphene
Kadi, Faris; Winzer, Torben; Knorr, Andreas; Malic, Ermin
2015-01-01
We present a microscopic study on the impact of doping on the carrier dynamics in graphene, in particular focusing on its influence on the technologically relevant carrier multiplication in realistic, doped graphene samples. Treating the time- and momentum-resolved carrier-light, carrier-carrier, and carrier-phonon interactions on the same microscopic footing, the appearance of Auger-induced carrier multiplication up to a Fermi level of 300 meV is revealed. Furthermore, we show that doping favors the so-called hot carrier multiplication occurring within one band. Our results are directly compared to recent time-resolved ARPES measurements and exhibit an excellent agreement on the temporal evolution of the hot carrier multiplication for n- and p-doped graphene. The gained insights shed light on the ultrafast carrier dynamics in realistic, doped graphene samples. PMID:26577536
Almstrand, Robert; Persson, Frank; Daims, Holger; Ekenberg, Maria; Christensson, Magnus; Wilén, Britt-Marie; Sörensson, Fred; Hermansson, Malte
2014-01-01
Moving bed biofilm reactors (MBBRs) are increasingly used for nitrogen removal with nitritation-anaerobic ammonium oxidation (anammox) processes in wastewater treatment. Carriers provide protected surfaces where ammonia oxidizing bacteria (AOB) and anammox bacteria form complex biofilms. However, the knowledge about the organization of microbial communities in MBBR biofilms is sparse. We used new cryosectioning and imaging methods for fluorescence in situ hybridization (FISH) to study the structure of biofilms retrieved from carriers in a nitritation-anammox MBBR. The dimensions of the carrier compartments and the biofilm cryosections after FISH showed good correlation, indicating little disturbance of biofilm samples by the treatment. FISH showed that Nitrosomonas europaea/eutropha-related cells dominated the AOB and Candidatus Brocadia fulgida-related cells dominated the anammox guild. New carriers were initially colonized by AOB, followed by anammox bacteria proliferating in the deeper biofilm layers, probably in anaerobic microhabitats created by AOB activity. Mature biofilms showed a pronounced three-dimensional stratification where AOB dominated closer to the biofilm-water interface, whereas anammox were dominant deeper into the carrier space and towards the walls. Our results suggest that current mathematical models may be oversimplifying these three-dimensional systems and unless the multidimensionality of these systems is considered, models may result in suboptimal design of MBBR carriers. PMID:24481066
Rapid Pneumatic Transport of Radioactive Samples - RaPToRS
NASA Astrophysics Data System (ADS)
Padalino, S.; Barrios, M.; Sangster, C.
2005-10-01
Some ICF neutron activation diagnostics require quick retrieval of the activated sample. Minimizing retrieval times is particularly important when the half-life of the activated material is on the order of the transport time or the degree of radioactivity is close to the background counting level. These restrictions exist in current experiments performed at the Laboratory for Laser Energetics, thus motivating the development of the RaPToRS system. The system has been designed to minimize transportation time while requiring no human intervention during transport or counting. These factors will be important if the system is to be used at the NIF where radiological hazards will be present during post activation. The sample carrier is pneumatically transported via a 4 inch ID PVC pipe to a remote location in excess of 100 meters from the activation site at a speed of approximately 7 m/s. It arrives at an end station where it is dismounted robotically from the carrier and removed from its hermetic package. The sample is then placed by the robot in a counting station. This system is currently being developed to measure back-to-back gamma rays produced by positron annihilation which were emitted by activated graphite. Funded in part by the U.S. DOE under sub contract with LLE at the University of Rochester.
Simple gas chromatographic system for analysis of microbial respiratory gases
NASA Technical Reports Server (NTRS)
Carle, G. C.
1972-01-01
Dual column ambient temperature system, consisting of pair of capillary columns, microbead thermistor detector and micro gas-sampling valve, is used in remote life-detection equipment for space experiments. Performance outweighs advantage gained by utilizing single-column systems to reduce weight, conserve carrier gas and operate at lower power levels.
Tests of positive ion beams from a microwave ion source for AMS
NASA Astrophysics Data System (ADS)
Schneider, R. J.; von Reden, K. F.; Hayes, J. M.; Wills, J. S. C.; Kern, W. G. E.; Kim, S.-W.
2000-10-01
A test facility has been constructed to evaluate high-current positive ion beams from small gaseous samples for AMS applications. The major components include a compact permanent magnet microwave ion source built at the AECL Chalk River Laboratory and now on loan from the University of Toronto, and a double-focusing spectrometer magnet on loan from Argonne National Laboratory. Samples are introduced by means of a silica capillary injection system. Loop injection into a carrier gas provides a stable feed for the microwave driven plasma. The magnetic analysis system is utilized to isolate carbon ions derived from CO 2 samples from other products of the plasma discharge, including argon ions of the carrier gas. With a smaller discharge chamber, we hope to exceed a conversion efficiency of 14% for carbon ions produced per atom, which we reported at AMS-7. The next step will be to construct an efficient charge-exchange cell, to produce negative ions for injection into the WHOI recombinator injector.
NASA Technical Reports Server (NTRS)
Sydor, John T.
1988-01-01
Samples of speech modulated by narrowband frequency modulation (NBFM) (cellular) and amplitude companded single sideband (ACSSB) radios were subjected to simulated co- and adjacent channel interference environments typical of proposed frequency division multiple access (FDMA) mobile satellite systems. These samples were then listened to by a group of evaluators whose subjective responses to the samples were used to produce a series of graphs showing the relationship between subjective acceptability, carrier to noise density (C/No), carrier to interference ratio (C/I), and frequency offset. The results show that in a mobile satellite environment, ACSSB deteriorates more slowly than NBFM. The co- and adjacent channel protection ratios for both modulation techniques were roughly the same, even though the mechanism for signal deterioration is different.
BPSK Demodulation Using Digital Signal Processing
NASA Technical Reports Server (NTRS)
Garcia, Thomas R.
1996-01-01
A digital communications signal is a sinusoidal waveform that is modified by a binary (digital) information signal. The sinusoidal waveform is called the carrier. The carrier may be modified in amplitude, frequency, phase, or a combination of these. In this project a binary phase shift keyed (BPSK) signal is the communication signal. In a BPSK signal the phase of the carrier is set to one of two states, 180 degrees apart, by a binary (i.e., 1 or 0) information signal. A digital signal is a sampled version of a "real world" time continuous signal. The digital signal is generated by sampling the continuous signal at discrete points in time. The rate at which the signal is sampled is called the sampling rate (f(s)). The device that performs this operation is called an analog-to-digital (A/D) converter or a digitizer. The digital signal is composed of the sequence of individual values of the sampled BPSK signal. Digital signal processing (DSP) is the modification of the digital signal by mathematical operations. A device that performs this processing is called a digital signal processor. After processing, the digital signal may then be converted back to an analog signal using a digital-to-analog (D/A) converter. The goal of this project is to develop a system that will recover the digital information from a BPSK signal using DSP techniques. The project is broken down into the following steps: (1) Development of the algorithms required to demodulate the BPSK signal; (2) Simulation of the system; and (3) Implementation a BPSK receiver using digital signal processing hardware.
Hug, Martina; Dorner, Marcus; Fröhlich, Franziska Zucol; Gysin, Claudine; Neuhaus, Diego; Nadal, David; Berger, Christoph
2010-10-15
Human-to-human transmission of the persistent infection establishing Epstein-Barr virus (EBV) occurs via saliva. Tonsils act as important portal of entry and exit of EBV. The contagiousness of pediatric EBV carriers and the role played by tonsillar enlargement (TE) are not known. We compared EBV shedding in mouthwash samples from pediatric EBV carriers with or without TE to that in mouthwash samples from pediatric patients with infectious mononucleosis (IM), the symptomatic form of primary infection if delayed after the age of 5 years. EBV DNA was quantified by polymerase chain reaction, and contagiousness was assessed using the cord lymphocyte transformation assay. EBV carriers with TE shed EBV DNA at an almost similar frequency (although in lower amounts) as pediatric patients with acute IM but more frequently (P <.001) and in higher amounts (P = .038) than EBV carriers without TE. EBV DNA levels in mouthwash samples from EBV carriers with TE mirrored levels in tonsils and gradually declined after tonsillectomy. Almost half of the mouthwash samples from pediatric EBV carriers contained infectious EBV. Pediatric EBV carriers--in particular, those with TE-may considerably contribute to the spreading of EBV in industrialized countries.
Atkinson, David A.
2002-01-01
Methods and apparatus for ion mobility spectrometry and analyte detection and identification verification system are disclosed. The apparatus is configured to be used in an ion mobility spectrometer and includes a plurality of reactant reservoirs configured to contain a plurality of reactants which can be reacted with the sample to form adducts having varying ion mobilities. A carrier fluid, such as air or nitrogen, is used to carry the sample into the spectrometer. The plurality of reactants are configured to be selectively added to the carrier stream by use inlet and outlet manifolds in communication with the reagent reservoirs, the reservoirs being selectively isolatable by valves. The invention further includes a spectrometer having the reagent system described. In the method, a first reactant is used with the sample. Following a positive result, a second reactant is used to determine whether a predicted response occurs. The occurrence of the second predicted response tends to verify the existence of a component of interest within the sample. A third reactant can also be used to provide further verification of the existence of a component of interest. A library can be established of known responses of compounds of interest with various reactants and the results of a specific multi-reactant survey of a sample can be compared against the library to determine whether a component detected in the sample is likely to be a specific component of interest.
NASA aviation safety reporting system
NASA Technical Reports Server (NTRS)
1979-01-01
The human factors frequency considered a cause of or contributor to hazardous events onboard air carriers are examined with emphasis on distractions. Safety reports that have been analyzed, processed, and entered into the aviation safety reporting system data base are discussed. A sampling of alert bulletins and responses to them is also presented.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-25
... Carrier Management Information System (MCMIS) System of Records AGENCY: Federal Motor Carrier Safety... Administration DOT/FMCSA 001 Motor Carrier Management Information System System of Records.'' This system of... Federal Motor Carrier Safety Administration--DOT/FMCSA 001 Motor Carrier Management Information System...
CARRIER/CASK HANDLING SYSTEM DESCRIPTION DOCUMENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
E.F. Loros
2000-06-23
The Carrier/Cask Handling System receives casks on railcars and legal-weight trucks (LWTs) (transporters) that transport loaded casks and empty overpacks to the Monitored Geologic Repository (MGR) from the Carrier/Cask Transport System. Casks that come to the MGR on heavy-haul trucks (HHTs) are transferred onto railcars before being brought into the Carrier/Cask Handling System. The system is the interfacing system between the railcars and LWTs and the Assembly Transfer System (ATS) and Canister Transfer System (CTS). The Carrier/Cask Handling System removes loaded casks from the cask transporters and transfers the casks to a transfer cart for either the ATS or CTS,more » as appropriate, based on cask contents. The Carrier/Cask Handling System receives the returned empty casks from the ATS and CTS and mounts the casks back onto the transporters for reshipment. If necessary, the Carrier/Cask Handling System can also mount loaded casks back onto the transporters and remove empty casks from the transporters. The Carrier/Cask Handling System receives overpacks from the ATS loaded with canisters that have been cut open and emptied and mounts the overpacks back onto the transporters for disposal. If necessary, the Carrier/Cask Handling System can also mount empty overpacks back onto the transporters and remove loaded overpacks from them. The Carrier/Cask Handling System is located within the Carrier Bay of the Waste Handling Building System. The system consists of cranes, hoists, manipulators, and supporting equipment. The Carrier/Cask Handling System is designed with the tooling and fixtures necessary for handling a variety of casks. The Carrier/Cask Handling System performance and reliability are sufficient to support the shipping and emplacement schedules for the MGR. The Carrier/Cask Handling System interfaces with the Carrier/Cask Transport System, ATS, and CTS as noted above. The Carrier/Cask Handling System interfaces with the Waste Handling Building System for building structures and space allocations. The Carrier/Cask Handling System interfaces with the Waste Handling Building Electrical System for electrical power.« less
Magnetic Nanoparticle Drug Carriers and their Study by Quadrupole Magnetic Field-Flow Fractionation
Williams, P. Stephen; Carpino, Francesca; Zborowski, Maciej
2009-01-01
Magnetic nanoparticle drug carriers continue to attract considerable interest for drug targeting in the treatment of cancers and other pathological conditions. The efficient delivery of therapeutic levels of drug to a target site while limiting nonspecific, systemic toxicity requires optimization of the drug delivery materials, the applied magnetic field, and the treatment protocol. The history and current state of magnetic drug targeting is reviewed. While initial studies involved micron-sized and larger carriers, and work with these microcarriers continues, it is the sub-micron carriers or nanocarriers that are of increasing interest. An aspect of magnetic drug targeting using nanoparticle carriers that has not been considered is then addressed. This aspect involves the variation in the magnetic properties of the nanocarriers. Quadrupole magnetic field-flow fractionation (QMgFFF) is a relatively new technique for characterizing magnetic nanoparticles. It is unique in its capability of determining the distribution in magnetic properties of a nanoparticle sample in suspension. The development and current state of this technique is also reviewed. Magnetic nanoparticle drug carriers have been found by QMgFFF analysis to be highly polydisperse in their magnetic properties, and the strength of response of the particles to magnetic field gradients is predicted to vary by orders of magnitude. It is expected that the least magnetic fraction of a formulation will contribute the most to systemic toxicity, and the depletion of this fraction will result in a more effective drug carrying material. A material that has a reduced systemic toxicity will allow higher doses of cytotoxic drugs to be delivered to the tumor with reduced side effects. Preliminary experiments involving a novel method of refining a magnetic nanoparticle drug carrier to achieve this result are described. QMgFFF is used to characterize the refined and unrefined material. PMID:19591456
Apparatus and method for measuring minority carrier lifetimes in semiconductor materials
Ahrenkiel, Richard K.; Johnston, Steven W.
2001-01-01
An apparatus for determining the minority carrier lifetime of a semiconductor sample includes a positioner for moving the sample relative to a coil. The coil is connected to a bridge circuit such that the impedance of one arm of the bridge circuit is varied as sample is positioned relative to the coil. The sample is positioned relative to the coil such that any change in the photoconductance of the sample created by illumination of the sample creates a linearly related change in the input impedance of the bridge circuit. In addition, the apparatus is calibrated to work at a fixed frequency so that the apparatus maintains a consistently high sensitivity and high linearity for samples of different sizes, shapes, and material properties. When a light source illuminates the sample, the impedance of the bridge circuit is altered as excess carriers are generated in the sample, thereby producing a measurable signal indicative of the minority carrier lifetimes or recombination rates of the sample.
Apparatus for measuring minority carrier lifetimes in semiconductor materials
Ahrenkiel, R.K.
1999-07-27
An apparatus for determining the minority carrier lifetime of a semiconductor sample includes a positioner for moving the sample relative to a coil. The coil is connected to a bridge circuit such that the impedance of one arm of the bridge circuit is varied as sample is positioned relative to the coil. The sample is positioned relative to the coil such that any change in the photoconductance of the sample created by illumination of the sample creates a linearly related change in the input impedance of the bridge circuit. In addition, the apparatus is calibrated to work at a fixed frequency so that the apparatus maintains a consistently high sensitivity and high linearly for samples of different sizes, shapes, and material properties. When a light source illuminates the sample, the impedance of the bridge circuit is altered as excess carriers are generated in the sample, thereby producing a measurable signal indicative of the minority carrier lifetimes or recombination rates of the sample. 17 figs.
Apparatus for measuring minority carrier lifetimes in semiconductor materials
Ahrenkiel, Richard K.
1999-01-01
An apparatus for determining the minority carrier lifetime of a semiconductor sample includes a positioner for moving the sample relative to a coil. The coil is connected to a bridge circuit such that the impedance of one arm of the bridge circuit is varied as sample is positioned relative to the coil. The sample is positioned relative to the coil such that any change in the photoconductance of the sample created by illumination of the sample creates a linearly related change in the input impedance of the bridge circuit. In addition, the apparatus is calibrated to work at a fixed frequency so that the apparatus maintains a consistently high sensitivity and high linearly for samples of different sizes, shapes, and material properties. When a light source illuminates the sample, the impedance of the bridge circuit is altered as excess carriers are generated in the sample, thereby producing a measurable signal indicative of the minority carrier lifetimes or recombination rates of the sample.
A novel nano-carrier transdermal gel against inflammation.
Chaudhary, Hema; Kohli, Kanchan; Kumar, Vikash
2014-04-25
The objective was to develop a stable, reproducible and patient non-infringing novel transdermal drug delivery system "nano-carrier transdermal gel" (NCTG) in combination of partial dose replacement of diclofenac diethylamine (DDEA) by curcumin (CRM). The drug content of gel was 99.30 and 97.57% for DDEA and CRM. Plasma samples were analyzed by liquid chromatography with triple-quadrupole tandem mass spectrometer (LC-MS/MS). Data were integrated with Analyst™ and analyzed by WinNonlin; stability parameters were analyzed using Tukey-Kramer multiple comparison test. Its average skin irritation scored 0.49 concluded to be non-irritant, safe for human use and in vivo studies revealed significantly greater extent of absorption and highly significant inhibition (%) of carrageenan induced paw edema. The results also demonstrated that encapsulation of drugs in nano-carrier increases its biological activity due to superior skin penetration potential. Hence, a novel once day transdermal gel of nano-carrier (nano-transfersomes; deformable vesicular) is achieved, to increase systemic availability, subsequent reduction in dose and toxicity of DDEA was developed for the treatment of inflammation. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Chen, Ke; Roy, Anupam; Rai, Amritesh; Movva, Hema C. P.; Meng, Xianghai; He, Feng; Banerjee, Sanjay K.; Wang, Yaguo
2018-05-01
Defect-carrier interaction in transition metal dichalcogenides (TMDs) plays important roles in carrier relaxation dynamics and carrier transport, which determines the performance of electronic devices. With femtosecond laser time-resolved spectroscopy, we investigated the effect of grain boundary/edge defects on the ultrafast dynamics of photoexcited carrier in molecular beam epitaxy (MBE)-grown MoTe2 and MoSe2. We found that, comparing with exfoliated samples, the carrier recombination rate in MBE-grown samples accelerates by about 50 times. We attribute this striking difference to the existence of abundant grain boundary/edge defects in MBE-grown samples, which can serve as effective recombination centers for the photoexcited carriers. We also observed coherent acoustic phonons in both exfoliated and MBE-grown MoTe2, indicating strong electron-phonon coupling in this materials. Our measured sound velocity agrees well with the previously reported result of theoretical calculation. Our findings provide a useful reference for the fundamental parameters: carrier lifetime and sound velocity and reveal the undiscovered carrier recombination effect of grain boundary/edge defects, both of which will facilitate the defect engineering in TMD materials for high speed opto-electronics.
Hit detection in serial femtosecond crystallography using X-ray spectroscopy of plasma emission.
Jönsson, H Olof; Caleman, Carl; Andreasson, Jakob; Tîmneanu, Nicuşor
2017-11-01
Serial femtosecond crystallography is an emerging and promising method for determining protein structures, making use of the ultrafast and bright X-ray pulses from X-ray free-electron lasers. The upcoming X-ray laser sources will produce well above 1000 pulses per second and will pose a new challenge: how to quickly determine successful crystal hits and avoid a high-rate data deluge. Proposed here is a hit-finding scheme based on detecting photons from plasma emission after the sample has been intercepted by the X-ray laser. Plasma emission spectra are simulated for systems exposed to high-intensity femtosecond pulses, for both protein crystals and the liquid carrier systems that are used for sample delivery. The thermal radiation from the glowing plasma gives a strong background in the XUV region that depends on the intensity of the pulse, around the emission lines from light elements (carbon, nitrogen, oxygen). Sample hits can be reliably distinguished from the carrier liquid based on the characteristic emission lines from heavier elements present only in the sample, such as sulfur. For buffer systems with sulfur present, selenomethionine substitution is suggested, where the selenium emission lines could be used both as an indication of a hit and as an aid in phasing and structural reconstruction of the protein.
Method for the detection of nitro-containing compositions using ultraviolet photolysis
Reagen, William K.; Lancaster, Gregory D.; Partin, Judy K.; Moore, Glenn A.
2000-01-01
A method for detecting nitro-containing compositions (e.g. nitrate/nitrite materials) in water samples and on solid substrates. In a water sample, ultraviolet light is applied to the sample so that dissolved nitro compositions therein will photolytically dissociate into gaseous nitrogen oxides (NO.sub.2(g) and/or NO.sub.(g)). A carrier gas is then introduced into the sample to generate a gaseous stream which includes the carrier gas combined with any gaseous nitrogen oxides. The carrier gas is thereafter directed into a detector. To detect nitro-compositions on solid substrates, ultraviolet light is applied thereto. A detector is then used to detect any gaseous nitrogen oxides which are photolytically generated during ultraviolet illumination. An optional carrier gas may be applied to the substrate during illumination to produce a gaseous stream which includes the carrier gas and any gaseous nitrogen oxides. The gaseous stream is then supplied to the detector.
Comparison of two closed carriers for vitrification of human blastocysts in a donor program.
Guerrero, Jaime; Gallardo, Miguel; Rodríguez-Arnedo, Adoración; Ten, Jorgen; Bernabeu, Rafael
2018-04-01
The survival of human blastocysts to vitrification with two different carriers is compared. Both vitrification carriers used in this study are in the category of closed carriers, as they completely isolate the samples from direct contact with liquid nitrogen or its vapours during cooling and storage, until warming. This characteristic is appealing because it reduces or eliminates the theoretical risk of cross-contamination during that period of time. The two closed vitrification systems used present very different design and features: in the High Security Vitrification device, the carrier straw containing the embryos is encapsulated inside an external straw before plunging in liquid nitrogen, resulting in thermal insulation during cooling. On the other hand, in the SafeSpeed carrier embryos are loaded in a thin-walled, narrow capillary designed to maximize the thermal transference. Both closed carriers achieved comparable outcomes in terms of survival of blastocysts to the vitrification process, with 97.5% vs. 96.1% survival with HSV and SafeSpeed, respectively. In conclusion, the cooling and warming rates at which these carriers operate, in combination with the cytosolic solute concentration in the cells of the cryopreserved blastocysts attained after a cryoprotectant-loading protocol, result in successful vitrification of human blastocysts for human assisted reproduction. Copyright © 2018. Published by Elsevier Inc.
RaPToRS Sample Delivery System
NASA Astrophysics Data System (ADS)
Henchen, Robert; Shibata, Kye; Krieger, Michael; Pogozelski, Edward; Padalino, Stephen; Glebov, Vladimir; Sangster, Craig
2010-11-01
At various labs (NIF, LLE, NRL), activated material samples are used to measure reaction properties. The Rapid Pneumatic Transport of Radioactive Samples (RaPToRS) system quickly and safely moves these radioactive samples through a closed PVC tube via airflow. The carrier travels from the reaction chamber to the control and analysis station, pneumatically braking at the outlet. A reversible multiplexer routes samples from various locations near the shot chamber to the analysis station. Also, the multiplexer allows users to remotely load unactivated samples without manually approaching the reaction chamber. All elements of the system (pneumatic drivers, flow control valves, optical position sensors, multiplexers, Geiger counters, and release gates at the analysis station) can be controlled manually or automatically using a custom LabVIEW interface. A prototype is currently operating at NRL in Washington DC. Prospective facilities for Raptors systems include LLE and NIF.
40 CFR 141.802 - Coliform sampling plan.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Section 141.802 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.802 Coliform... aircraft water system owned or operated by the air carrier that identifies the following: (1) Coliform...
40 CFR 141.802 - Coliform sampling plan.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Section 141.802 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.802 Coliform... aircraft water system owned or operated by the air carrier that identifies the following: (1) Coliform...
40 CFR 141.802 - Coliform sampling plan.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Section 141.802 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.802 Coliform... aircraft water system owned or operated by the air carrier that identifies the following: (1) Coliform...
DOT National Transportation Integrated Search
2000-10-01
There has been interest in the extent to which motor carriers are in compliance with Part 382 of the Federal Motor Carrier Safety Regulations (Controlled Substances and Alcohol Use Testing), as well as the extent to which the Federal Motor Carrier Sa...
Carrier screening in the era of expanding genetic technology.
Arjunan, Aishwarya; Litwack, Karen; Collins, Nick; Charrow, Joel
2016-12-01
The Center for Jewish Genetics provides genetic education and carrier screening to individuals of Jewish descent. Carrier screening has traditionally been performed by targeted mutation analysis for founder mutations with an enzyme assay for Tay-Sachs carrier detection. The development of next-generation sequencing (NGS) allows for higher detection rates regardless of ethnicity. Here, we explore differences in carrier detection rates between genotyping and NGS in a primarily Jewish population. Peripheral blood samples or saliva samples were obtained from 506 individuals. All samples were analyzed by sequencing, targeted genotyping, triplet-repeat detection, and copy-number analysis; the analyses were carried out at Counsyl. Of 506 individuals screened, 288 were identified as carriers of at least 1 condition and 8 couples were carriers for the same disorder. A total of 434 pathogenic variants were identified. Three hundred twelve variants would have been detected via genotyping alone. Although no additional mutations were detected by NGS in diseases routinely screened for in the Ashkenazi Jewish population, 26.5% of carrier results and 2 carrier couples would have been missed without NGS in the larger panel. In a primarily Jewish population, NGS reveals a larger number of pathogenic variants and provides individuals with valuable information for family planning.Genet Med 18 12, 1214-1217.
Laser excited confocal microscope fluorescence scanner and method
Mathies, Richard A.; Peck, Konan
1992-01-01
A fluorescent scanner for scanning the fluorescence from a fluorescence labeled separated sample on a sample carrier including a confocal microscope for illuminating a predetermined volume of the sample carrier and/or receiving and processing fluorescence emissions from said volume to provide a display of the separated sample.
A recently developed, commercially available, open-air, surface sampling ion source for mass spectrometers provides individual analyses in several seconds. To realize its full throughput potential, an autosampler and field sample carrier were designed and built. The autosampler ...
Maes, Jan; Verlooy, Lien; Buenafe, Olivia E.; de Witte, Peter A. M.; Esguerra, Camila V.; Crawford, Alexander D.
2012-01-01
Zebrafish are rapidly growing in popularity as an in vivo model system for chemical genetics, drug discovery, and toxicology, and more recently also for natural product discovery. Experiments involving the pharmacological evaluation of small molecules or natural product extracts in zebrafish bioassays require the effective delivery of these compounds to embryos and larvae. While most samples to be screened are first solubilized in dimethyl sulfoxide (DMSO), which is then diluted in the embryo medium, often this method is not sufficient to prevent the immediate or eventual precipitation of the sample. Certain compounds and extracts are also not highly soluble in DMSO. In such instances the use of carriers and/or other solvents might offer an alternative means to achieve the required sample concentration. Towards this end, we determined the maximum tolerated concentration (MTC) of several commonly used solvents and carriers in zebrafish embryos and larvae at various developmental stages. Solvents evaluated for this study included acetone, acetonitrile, butanone, dimethyl formamide, DMSO, ethanol, glycerol, isopropanol, methanol, polyethylene glycol (PEG-400), propylene glycol, and solketal, and carriers included albumin (BSA) and cyclodextrin (2-hydroxypropyl-beta-cyclodextrin, or HPBCD). This study resulted in the identification of polyethylene glycol (PEG400), propylene glycol, and methanol as solvents that were relatively well-tolerated over a range of developmental stages. In addition, our results showed that acetone was well-tolerated by embryos but not by larvae, and 1% cyclodextrin (HPBCD) was well-tolerated by both embryos and larvae, indicating the utility of this carrier for compound screening in zebrafish. However, given the relatively small differences (2–3 fold) between concentrations that are apparently safe and those that are clearly toxic, further studies – e.g. omics analyses –should be carried out to determine which cellular processes and signalling pathways are affected by any solvents and carriers that are used for small-molecule screens in zebrafish. PMID:23082109
Sjögren, Erik; Bredberg, Ulf; Lennernäs, Hans
2012-04-02
The predictive power of using in vitro systems in combination with physiologically based pharmacokinetic (PBPK) modeling to elucidate the relative importance of metabolism and carrier-mediated transport for the pharmacokinetics was evaluated using repaglinide as a model compound and pig as the test system. Repaglinide was chosen as model drug as previous studies in humans have shown that repaglinide is subject to both carrier-mediated influx to the liver cells and extensive hepatic metabolism. A multiple sampling site model in pig was chosen since it provides detailed in vivo information about the liver disposition. The underlying assumption was that both metabolism and carrier-mediated transport are also important for the hepatic disposition of repaglinide in pigs. Microsomes and primary hepatocytes were used for in vitro evaluation of enzyme kinetics and cellular disposition, respectively. In vitro data were generated both with and without metabolism inhibitors (ketoconazole, bezafibrate and trimethoprim) and transport inhibitors (diclofenac and quinine) providing input into a semi-PBPK model. In vivo data were also generated with and without the same enzyme and transporter inhibitors, alone and in combination. The pigs were given repaglinide as intravenous infusions with and without inhibitors in a sequential manner, i.e., a control phase and a test phase. Parameters describing the passive and carrier-mediated flux as well as metabolism were estimated in the control phase. The result from test phase was used to gain further knowledge of the findings from the control phase. The in vivo pig model enabled simultaneous sampling from plasma (pre- and postliver and peripheral) as well as from bile and urine. A semi-PBPK model consisting of 11 compartments (6 tissues + 5 sampling sites) was constructed for the mechanistic elucidation of the liver disposition, in vitro based in vivo predictions, sensitivity analyses and estimations of individual pharmacokinetic parameters. Both in vitro and in vivo results showed that carrier-mediated influx was important for the liver disposition. The in vivo findings were supported by the result from the test phase where hepatic clearance (4.3 mL min⁻¹ kg⁻¹) was decreased by 29% (metabolism inhibition), 43% (transport inhibition) and 57% (metabolism + transport inhibition). These effects were in good agreement with predicted levels. This study suggests that both metabolism and carrier-mediated uptake are of significant importance for the liver disposition of repaglinide in pigs.
A novel grating-imaging method to measure carrier diffusion coefficient in graphene
NASA Astrophysics Data System (ADS)
Chen, Ke; Wang, Yaguo; Akinwande, Deji; Bank, Seth; Lin, Jung-Fu
Similar to carrier mobility, carrier diffusion coefficient in graphene determines the response rate of future graphene-based electronics. Here we present a simple, sensitive and non-destructive technique integrated with ultrafast pump-probe spectroscopy to measure carrier diffusion in CVD-grown graphene. In the method, the pump and the probe beams pass through the same area of a photomask with metal strips i.e. a transmission amplitude grating, and get diffracted. The diffracted light is collected by an objective lens and focused onto the sample to generate carrier density grating. Relaxation of this carrier density grating is governed by both carrier recombination and carrier diffusion in the sample. Transient transmission change of the probe beams, which reflects this relaxation process, is recorded. The measured diffusion coefficients of multilayer and monolayer CVD-grown graphene are 2000cm2/s and 10000cm2/s, respectively, comparable with the reported values of epitaxial graphene and reduced graphene. This transmission grating technique can be used to measure carrier dynamics in versatile 2D materials.
Laser excited confocal microscope fluorescence scanner and method
Mathies, R.A.; Peck, K.
1992-02-25
A fluorescent scanner is designed for scanning the fluorescence from a fluorescence labeled separated sample on a sample carrier. The scanner includes a confocal microscope for illuminating a predetermined volume of the sample carrier and/or receiving and processing fluorescence emissions from the volume to provide a display of the separated sample. 8 figs.
21 CFR 203.30 - Sample distribution by mail or common carrier.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Sample distribution by mail or common carrier. 203.30 Section 203.30 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL PRESCRIPTION DRUG MARKETING Samples § 203.30 Sample distribution by...
Differential atmospheric tritium sampler
Griesbach, O.A.; Stencel, J.R.
1987-10-02
An atmospheric tritium sampler is provided which uses a carrier gas comprised of hydrogen gas and a diluting gas, mixed in a nonexplosive concentration. Sample air and carrier gas are drawn into and mixed in a manifold. A regulator meters the carrier gas flow to the manifold. The air sample/carrier gas mixture is pulled through a first moisture trap which adsorbs water from the air sample. The moisture then passes through a combustion chamber where hydrogen gas in the form of H/sub 2/ or HT is combusted into water. The manufactured water is transported by the air stream to a second moisture trap where it is adsorbed. The air is then discharged back into the atmosphere by means of a pump.
Differential atmospheric tritium sampler
Griesbach, Otto A.; Stencel, Joseph R.
1990-01-01
An atmospheric tritium sampler is provided which uses a carrier gas comprised of hydrogen gas and a diluting gas, mixed in a nonexplosive concentration. Sample air and carrier gas are drawn into and mixed in a manifold. A regulator meters the carrier gas flow to the manifold. The air sample/carrier gas mixture is pulled through a first moisture trap which adsorbs water from the air sample. The mixture then passes through a combustion chamber where hydrogen gas in the form of H.sub.2 or HT is combusted into water. The manufactured water is transported by the air stream to a second moisture trap where it is adsorbed. The air is then discharged back into the atmosphere by means of a pump.
A Carrier Estimation Method Based on MLE and KF for Weak GNSS Signals.
Zhang, Hongyang; Xu, Luping; Yan, Bo; Zhang, Hua; Luo, Liyan
2017-06-22
Maximum likelihood estimation (MLE) has been researched for some acquisition and tracking applications of global navigation satellite system (GNSS) receivers and shows high performance. However, all current methods are derived and operated based on the sampling data, which results in a large computation burden. This paper proposes a low-complexity MLE carrier tracking loop for weak GNSS signals which processes the coherent integration results instead of the sampling data. First, the cost function of the MLE of signal parameters such as signal amplitude, carrier phase, and Doppler frequency are used to derive a MLE discriminator function. The optimal value of the cost function is searched by an efficient Levenberg-Marquardt (LM) method iteratively. Its performance including Cramér-Rao bound (CRB), dynamic characteristics and computation burden are analyzed by numerical techniques. Second, an adaptive Kalman filter is designed for the MLE discriminator to obtain smooth estimates of carrier phase and frequency. The performance of the proposed loop, in terms of sensitivity, accuracy and bit error rate, is compared with conventional methods by Monte Carlo (MC) simulations both in pedestrian-level and vehicle-level dynamic circumstances. Finally, an optimal loop which combines the proposed method and conventional method is designed to achieve the optimal performance both in weak and strong signal circumstances.
CARRIER PREPARATION BUILDING MATERIALS HANDLING SYSTEM DESCRIPTION DOCUMENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
E.F. Loros
2000-06-28
The Carrier Preparation Building Materials Handling System receives rail and truck shipping casks from the Carrier/Cask Transport System, and inspects and prepares the shipping casks for return to the Carrier/Cask Transport System. Carrier preparation operations for carriers/casks received at the surface repository include performing a radiation survey of the carrier and cask, removing/retracting the personnel barrier, measuring the cask temperature, removing/retracting the impact limiters, removing the cask tie-downs (if any), and installing the cask trunnions (if any). The shipping operations for carriers/casks leaving the surface repository include removing the cask trunnions (if any), installing the cask tie-downs (if any), installingmore » the impact limiters, performing a radiation survey of the cask, and installing the personnel barrier. There are four parallel carrier/cask preparation lines installed in the Carrier Preparation Building with two preparation bays in each line, each of which can accommodate carrier/cask shipping and receiving. The lines are operated concurrently to handle the waste shipping throughputs and to allow system maintenance operations. One remotely operated overhead bridge crane and one remotely operated manipulator is provided for each pair of carrier/cask preparation lines servicing four preparation bays. Remotely operated support equipment includes a manipulator and tooling and fixtures for removing and installing personnel barriers, impact limiters, cask trunnions, and cask tie-downs. Remote handling equipment is designed to facilitate maintenance, dose reduction, and replacement of interchangeable components where appropriate. Semi-automatic, manual, and backup control methods support normal, abnormal, and recovery operations. Laydown areas and equipment are included as required for transportation system components (e.g., personnel barriers and impact limiters), fixtures, and tooling to support abnormal and recovery operations. The Carrier Preparation Building Materials Handling System interfaces with the Cask/Carrier Transport System to move the carriers to and from the system. The Carrier Preparation Building System houses the equipment and provides the facility, utility, safety, communications, and auxiliary systems supporting operations and protecting personnel.« less
Optical properties of nearly lattice-matched GaN/(Al,In)N quantum wells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liaugaudas, Gediminas; Jacopin, Gwénolé; Carlin, Jean-François
2016-05-28
We report a systematic study of the photoluminescence (PL) properties of a series of nearly lattice-matched (LM) GaN/(Al,In)N single quantum well (SQW) samples, with well thickness ranging from 1.5 to 5 nm, grown by metalorganic vapor phase epitaxy. Temperature dependent PL and time-resolved PL measurements reveal similar trends among the studied SQW samples, which also indicate strong localization effects. The observed PL energy behavior, akin to the S-shape, accompanied first by a narrowing and then a broadening of the PL line width with increasing temperature, closely resemble previous observations made on the more established (In,Ga)N/GaN QW system. The similar trends observedmore » in the PL features of those two QW systems imply that the PL properties of LM GaN/(Al,In)N SQW samples are also governed by localized states. The effects of carrier transfer among these localization sites are clearly observed for the 3 nm thick QW, evidenced by an increasing PL intensity in the lower energy spectral window and a concomitant increase in the corresponding PL decay time. Time-resolved data corroborate the picture of strongly localized carriers and also indicate that above a well thickness dependent delocalization temperature carrier distribution across the localized sites reaches thermal equilibrium, as the PL decay times over different spectral regions converge to the same value. Based on the difference between the calculated QW ground state transition energy, obtained using the envelope wave function formalism, and the measured PL energy, a localization energy of at least a few hundreds of meV has been extracted for all of the studied SQW samples. This rather large value also implies that In-related localization effects are more pronounced in the GaN/(Al,In)N system with respect to those in the (In,Ga)N/GaN one for a similar In content.« less
Wang, Yuhe; Li, Yanbin; Wang, Ronghui; Wang, Maohua; Lin, Jianhan
2017-04-01
As a result of the low concentration of avian influenza viruses in samples for routine screening, the separation and concentration of these viruses are vital for their sensitive detection. We present a novel three-dimensional printed magnetophoretic system for the continuous flow separation of the viruses using aptamer-modified magnetic nanoparticles, a magnetophoretic chip, a magnetic field, and a fluidic controller. The magnetic field was designed based on finite element magnetic simulation and developed using neodymium magnets with a maximum intensity of 0.65 T and a gradient of 32 T/m for dragging the nanoparticle-virus complexes. The magnetophoretic chip was designed by SOLIDWORKS and fabricated by a three-dimensional printer with a magnetophoretic channel for the continuous flow separation of the viruses using phosphate-buffered saline as carrier flow. The fluidic controller was developed using a microcontroller and peristaltic pumps to inject the carrier flow and the viruses. The trajectory of the virus-nanoparticle complexes was simulated using COMSOL for optimization of the carrier flow and the magnetic field, respectively. The results showed that the H5N1 viruses could be captured, separated, and concentrated using the proposed magnetophoretic system with the separation efficiency up to 88% in a continuous flow separation time of 2 min for a sample volume of 200 μL. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Tunable Fermi Contour Anisotropy in GaAs Electron and Hole Systems
NASA Astrophysics Data System (ADS)
Kamburov, Dobromir G.
This Thesis explores the ballistic transport of quasi two-dimensional (2D) electron and hole systems confined to GaAs quantum wells and subjected to a periodic, strain-induced density modulation. In the presence of an applied perpendicular magnetic field, whenever the diameter of the charged carriers' cyclotron orbit becomes commensurate with the period of the density modulation, the sample's resistance exhibits commensurability features. We use the commensurability effects to directly probe the size of the cyclotron orbit, the Fermi contour, and the spin-polarization of particles at low magnetic field and of composite fermions near even-denominator Landau level filling factors (nu). We establish how the commensurability signatures depend on the sample parameters, including the carrier density, the modulation period, and the width of the confining quantum well. In the presence of a small perpendicular magnetic field (B⊥ ), both 2D electrons and holes are essentially spin-unpolarized and their Fermi contours are nearly circular. When an additional parallel component B∥ is introduced, it couples to the carriers' out-of-plane motion and leads to a severe distortion of the energy bands and the Fermi contours. The degree of anisotropy is typically stronger in the wider quantum wells but it also depends on the carrier type. For a given QW width, holes become anisotropic more readily than electrons. The application of B ∥ also affects the spin-polarization of the carriers. Hole samples, for example, become more spin-polarized compared to electrons. We can semi-quantitatively explain the shape and size of the electron and hole Fermi contours with a theoretical calculation with no adjustable parameters based on an 8 x 8 Kane Hamiltonian. In addition to the electron and hole data at low perpendicular magnetic fields, we observe commensurability features for composite fermions near Landau level filling factors nu = 3=2, 1/2, and 1/4. Our data reveal an asymmetry of the composite fermion commensurability features on the two sides of filling factors nu = 1=2 and 3=2. The asymmetry is a fascinating manifestation of a subtle breaking of the particle-hole equivalence in the ballistic transport of composite fermions. It is consistent with a transport picture in which the minority carriers capture flux quanta to form composite fermions. We also employ commensurability oscillations as a tool to probe and quantify the effect of B∥ on the composite fermion Fermi contours. Our measurements reveal that, thanks to the finite layer thickness of the carriers and the coupling of their out-of-plane motion to B∥, the Fermi contours of nu = 1=2 and 3/2 composite fermions are significantly distorted. Furthermore, depending on the width of the quantum well and the sample density, in the vicinity of nu = 3=2 the spin-polarization of the composite fermions varies while near nu = 1=2 they remain fully spin-polarized.
Automated cassette-to-cassette substrate handling system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kraus, Joseph Arthur; Boyer, Jeremy James; Mack, Joseph
2014-03-18
An automated cassette-to-cassette substrate handling system includes a cassette storage module for storing a plurality of substrates in cassettes before and after processing. A substrate carrier storage module stores a plurality of substrate carriers. A substrate carrier loading/unloading module loads substrates from the cassette storage module onto the plurality of substrate carriers and unloads substrates from the plurality of substrate carriers to the cassette storage module. A transport mechanism transports the plurality of substrates between the cassette storage module and the plurality of substrate carriers and transports the plurality of substrate carriers between the substrate carrier loading/unloading module and amore » processing chamber. A vision system recognizes recesses in the plurality of substrate carriers corresponding to empty substrate positions in the substrate carrier. A processor receives data from the vision system and instructs the transport mechanism to transport substrates to positions on the substrate carrier in response to the received data.« less
Spatially resolved δ13C analysis using laser ablation isotope ratio mass spectrometry
NASA Astrophysics Data System (ADS)
Moran, J.; Riha, K. M.; Nims, M. K.; Linley, T. J.; Hess, N. J.; Nico, P. S.
2014-12-01
Inherent geochemical, organic matter, and microbial heterogeneity over small spatial scales can complicate studies of carbon dynamics through soils. Stable isotope analysis has a strong history of helping track substrate turnover, delineate rhizosphere activity zones, and identifying transitions in vegetation cover, but most traditional isotope approaches are limited in spatial resolution by a combination of physical separation techniques (manual dissection) and IRMS instrument sensitivity. We coupled laser ablation sampling with isotope measurement via IRMS to enable spatially resolved analysis over solid surfaces. Once a targeted sample region is ablated the resulting particulates are entrained in a helium carrier gas and passed through a combustion reactor where carbon is converted to CO2. Cyrotrapping of the resulting CO2 enables a reduction in carrier gas flow which improves overall measurement sensitivity versus traditional, high flow sample introduction. Currently we are performing sample analysis at 50 μm resolution, require 65 ng C per analysis, and achieve measurement precision consistent with other continuous flow techniques. We will discuss applications of the laser ablation IRMS (LA-IRMS) system to microbial communities and fish ecology studies to demonstrate the merits of this technique and how similar analytical approaches can be transitioned to soil systems. Preliminary efforts at analyzing soil samples will be used to highlight strengths and limitations of the LA-IRMS approach, paying particular attention to sample preparation requirements, spatial resolution, sample analysis time, and the types of questions most conducive to analysis via LA-IRMS.
47 CFR 61.134 - Concurrences for through services.
Code of Federal Regulations, 2011 CFR
2011-10-01
... or regulations for through services between points on its own system and points on another carrier's system (or systems), or between points on another carrier's system (or systems), must list all concurring, connecting or other participating carriers as provided in § 61.54 (f), (g) and (h). A concurring carrier must...
2012-01-01
The electroluminescence (EL) and photoluminescence of Si nanocrystals (Si-nc) from multilayered samples of Si/SiO are investigated. Si-nc are formed within Si and SiO layers after furnace annealing. It is found that the presence of Si interlayers creates extra carrier paths for EL emission. A comparative study is further performed on a multilayered Si/SiO sample and a single-layered one with Si and SiO homogeneously mixed. Both samples have the same ratio of Si to O and the same contents of Si and O. The multilayered sample is found to have higher EL intensity, less turn-on voltage, lower resistance, and higher current efficiency than the single-layered one. The results indicate that Si interlayers in Si/SiO may act as carrier channels, which promote carrier transport and enhance the EL emission of Si-nc. PMID:22448989
Johnston, Steven W.; Ahrenkiel, Richard K.
2002-01-01
An apparatus for measuring the minority carrier lifetime of a semiconductor sample using radio-frequency coupling. The measuring apparatus includes an antenna that is positioned a coupling distance from a semiconductor sample which is exposed to light pulses from a laser during sampling operations. A signal generator is included to generate high frequency, such as 900 MHz or higher, sinusoidal waveform signals that are split into a reference signal and a sample signal. The sample signal is transmitted into a sample branch circuit where it passes through a tuning capacitor and a coaxial cable prior to reaching the antenna. The antenna is radio-frequency coupled with the adjacent sample and transmits the sample signal, or electromagnetic radiation corresponding to the sample signal, to the sample and receives reflected power or a sample-coupled-photoconductivity signal back. To lower impedance and speed system response, the impedance is controlled by limiting impedance in the coaxial cable and the antenna reactance. In one embodiment, the antenna is a waveguide/aperture hybrid antenna having a central transmission line and an adjacent ground flange. The sample-coupled-photoconductivity signal is then transmitted to a mixer which also receives the reference signal. To enhance the sensitivity of the measuring apparatus, the mixer is operated to phase match the reference signal and the sample-coupled-photoconductivity signal.
Kann, Birthe; Windbergs, Maike
2013-04-01
Confocal Raman microscopy is an analytical technique with a steadily increasing impact in the field of pharmaceutics as the instrumental setup allows for nondestructive visualization of component distribution within drug delivery systems. Here, the attention is mainly focused on classic solid carrier systems like tablets, pellets, or extrudates. Due to the opacity of these systems, Raman analysis is restricted either to exterior surfaces or cross sections. As Raman spectra are only recorded from one focal plane at a time, the sample is usually altered to create a smooth and even surface. However, this manipulation can lead to misinterpretation of the analytical results. Here, we present a trendsetting approach to overcome these analytical pitfalls with a combination of confocal Raman microscopy and optical profilometry. By acquiring a topography profile of the sample area of interest prior to Raman spectroscopy, the profile height information allowed to level the focal plane to the sample surface for each spectrum acquisition. We first demonstrated the basic principle of this complementary approach in a case study using a tilted silica wafer. In a second step, we successfully adapted the two techniques to investigate an extrudate and a lyophilisate as two exemplary solid drug carrier systems. Component distribution analysis with the novel analytical approach was neither hampered by the curvature of the cylindrical extrudate nor the highly structured surface of the lyophilisate. Therefore, the combined analytical approach bears a great potential to be implemented in diversified fields of pharmaceutical sciences.
Minority carrier diffusion length extraction in Cu2ZnSn(Se,S)4 solar cells
NASA Astrophysics Data System (ADS)
Gokmen, Tayfun; Gunawan, Oki; Mitzi, David B.
2013-09-01
We report measurement of minority carrier diffusion length (Ld) for high performance Cu2ZnSn(S,Se)4 (CZTSSe) solar cells in comparison with analogous Cu(In,Ga)(S,Se)2 (CIGSSe) devices. Our Ld extraction method involves performing systematic measurements of the internal quantum efficiency combined with separate capacitance-voltage measurement. This method also enables the measurement of the absorption coefficient of the absorber material as a function of wavelength in a finished device. The extracted values of Ld for CZTSSe samples are at least factor of 2 smaller than those for CIGSSe samples. Combined with minority carrier lifetime (τ) data measured by time-resolved photoluminescence, we deduce the minority carrier mobility (μe), which is also relatively low for the CZTSSe samples.
Study of new systems concepts for a Titan atmospheric probe
NASA Technical Reports Server (NTRS)
Bernard, Doug; Citron, Todd; Drean, Robert; Lewis, Scott; Lo, Martin; Mccarthy, John; Soderblom, Robert; Steffy, Dave; Vargas, Tina; Wolff, Marty
1986-01-01
Results of a systems concepts study for a Titan Probe were examined. The key tradeoffs performed are described in detail. Mass breakdown of each Probe subsystem or major element were given. The mission analysis performed to determine compliance with the high altitude sampling and descent time requirements are described. The baseline Descent Module design was derived. The element of the Probe System left on the Carrier after separation were described.
NASA Astrophysics Data System (ADS)
Zhang, Ying; Mao, Xuefei; Liu, Jixin; Wang, Min; Qian, Yongzhong; Gao, Chengling; Qi, Yuehan
2016-04-01
In this work, a solid sampling device consisting of a tungsten coil trap, porous carbon vaporizer and on-line ashing furnace of a Ni-Cr coil was interfaced with inductively coupled plasma mass spectrometry (ICP-MS). A modified double gas circuit system was employed that was composed of carrier and supplemental gas lines controlled by separate gas mass flow controllers. For Cd determination in food samples using the assembled solid sampling ICP-MS, the optimal ashing and vaporization conditions, flow rate of the argon-hydrogen (Ar/H2) (v:v = 24:1) carrier gas and supplemental gas, and minimum sampling mass were investigated. Under the optimized conditions, the limit of quantification was 0.5 pg and the relative standard deviation was within a 10.0% error range (n = 10). Furthermore, the mean spiked recoveries for various food samples were 99.4%-105.9% (n = 6). The Cd concentrations measured by the proposed method were all within the certified values of the reference materials or were not significantly different (P > 0.05) from those of the microwave digestion ICP-MS method, demonstrating the good accuracy and precision of the solid sampling ICP-MS method for Cd determination in food samples.
Bradley, Bekh; Westen, Drew; Mercer, Kristina B; Binder, Elisabeth B; Jovanovic, Tanja; Crain, Daniel; Wingo, Aliza; Heim, Christine
2011-05-01
The ability to effectively regulate emotions and a secure attachment style are critical for maintaining mental health across the life span. The experience of childhood maltreatment interferes with normal development of emotional regulation and dramatically increases risk for a wide range of psychiatric disorders in adulthood. The central nervous system oxytocin systems are critically involved in mediating social attachment and buffering psychophysiological responses to stress. We therefore investigated the impact of childhood maltreatment and an oxytocin receptor (OXTR) single nucleotide polymorphism (rs53576) and their interaction on emotional dysregulation and attachment style in adulthood in a sample of low-income, African American men and women recruited from primary care clinics of an urban, public hospital. Consistent with prior research, we found that the severity of childhood maltreatment was associated with increased levels of emotional dysregulation in adulthood. Childhood maltreatment was also positively associated with ratings of disorganized/unresolved adult attachment style and negatively associated with ratings of secure adult attachment style. There was no direct association between rs53576 and emotional dysregulation or ratings of adult attachment style. However, there were significant interactions between rs53576 and childhood maltreatment in predicting level of adult emotional dysregulation and attachment style. Specifically, G/G genotype carriers were at risk for increased emotional dysregulation when exposed to three or more categories of childhood abuse. In addition, G/G genotype carriers exhibited enhanced disorganized adult attachment style when exposed to severe childhood abuse compared to A/A and A/G carriers. Our findings suggest that A allele carriers of OXTR rs53576 are resilient against the effects of severe childhood adversity, by protection against emotional dysregulation and disorganized attachment.
BRADLEY, BEKH; WESTEN, DREW; MERCER, KRISTINA B.; BINDER, ELISABETH B.; JOVANOVIC, TANJA; CRAIN, DANIEL; WINGO, ALIZA; HEIM, CHRISTINE
2015-01-01
The ability to effectively regulate emotions and a secure attachment style are critical for maintaining mental health across the life span. The experience of childhood maltreatment interferes with normal development of emotional regulation and dramatically increases risk for a wide range of psychiatric disorders in adulthood. The central nervous system oxytocin systems are critically involved in mediating social attachment and buffering psychophysiological responses to stress. We therefore investigated the impact of childhood maltreatment and an oxytocin receptor (OXTR) single nucleotide polymorphism (rs53576) and their interaction on emotional dysregulation and attachment style in adulthood in a sample of low-income, African American men and women recruited from primary care clinics of an urban, public hospital. Consistent with prior research, we found that the severity of childhood maltreatment was associated with increased levels of emotional dysregulation in adulthood. Childhood maltreatment was also positively associated with ratings of disorganized/unresolved adult attachment style and negatively associated with ratings of secure adult attachment style. There was no direct association between rs53576 and emotional dysregulation or ratings of adult attachment style. However, there were significant interactions between rs53576 and childhood maltreatment in predicting level of adult emotional dysregulation and attachment style. Specifically, G/G genotype carriers were at risk for increased emotional dysregulation when exposed to three or more categories of childhood abuse. In addition, G/G genotype carriers exhibited enhanced disorganized adult attachment style when exposed to severe childhood abuse compared to A/A and A/G carriers. Our findings suggest that A allele carriers of OXTR rs53576 are resilient against the effects of severe childhood adversity, by protection against emotional dysregulation and disorganized attachment. PMID:23786688
Carrier-separating demodulation of phase shifting self-mixing interferometry
NASA Astrophysics Data System (ADS)
Tao, Yufeng; Wang, Ming; Xia, Wei
2017-03-01
A carrier separating method associated with noise-elimination had been introduced into a sinusoidal phase-shifting self-mixing interferometer. The conventional sinusoidal phase shifting self-mixing interferometry was developed into a more competitive instrument with high computing efficiency and nanometer accuracy of λ / 100 in dynamical vibration measurement. The high slew rate electro-optic modulator induced a sinusoidal phase carrier with ultralow insertion loss in this paper. In order to extract phase-shift quickly and precisely, this paper employed the carrier-separating to directly generate quadrature signals without complicated frequency domain transforms. Moreover, most noises were evaluated and suppressed by a noise-elimination technology synthesizing empirical mode decomposition with wavelet transform. The overall laser system was described and inherent advantages such as high computational efficiency and decreased nonlinear errors of the established system were demonstrated. The experiment implemented on a high precision PZT (positioning accuracy was better than 1 nm) and compared with laser Doppler velocity meter. The good agreement of two instruments shown that the short-term resolution had improved from 10 nm to 1.5 nm in dynamic vibration measurement with reduced time expense. This was useful in precision measurement to improve the SMI with same sampling rate. The proposed signal processing was performed in pure time-domain requiring no preprocessing electronic circuits.
Sander, S; Behnisch, J; Wagner, M
2017-02-01
With the MBBR IFAS (moving bed biofilm reactor integrated fixed-film activated sludge) process, the biomass required for biological wastewater treatment is either suspended or fixed on free-moving plastic carriers in the reactor. Coarse- or fine-bubble aeration systems are used in the MBBR IFAS process. In this study, the oxygen transfer efficiency (OTE) of a coarse-bubble aeration system was improved significantly by the addition of the investigated carriers, even in-process (∼1% per vol-% of added carrier material). In a fine-bubble aeration system, the carriers had little or no effect on OTE. The effect of carriers on OTE strongly depends on the properties of the aeration system, the volumetric filling rate of the carriers, the properties of the carrier media, and the reactor geometry. This study shows that the effect of carriers on OTE is less pronounced in-process compared to clean water conditions. When designing new carriers in order to improve their effect on OTE further, suppliers should take this into account. Although the energy efficiency and cost effectiveness of coarse-bubble aeration systems can be improved significantly by the addition of carriers, fine-bubble aeration systems remain the more efficient and cost-effective alternative for aeration when applying the investigated MBBR IFAS process.
Lai, Junmin; Lin, Wu; Scholes, Peter; Li, Mingzhong
2017-01-01
The aim of the study was to investigate the effects of the loading factors, i.e., the initial drug loading concentration and the ratio of the drug to carriers, on the in vitro pharmaceutical performance of drug-loaded mesoporous systems. Ibuprofen (IBU) was used as a model drug, and two non-ordered mesoporous materials of commercial silica Syloid® 244FP (S244FP) and Neusilin® US2 (NS2) were selected in the study. The IBU-loaded mesoporous samples were prepared by a solvent immersion method with a rotary evaporation drying technique and characterized by polarized light microscopy (PLM), Fourier transform infrared (FTIR) spectroscopy, X-ray powder diffraction (XRPD) and differential scanning calorimetry (DSC). Dissolution experiments were performed in simulated gastric media at 37 °C under non-sink conditions. The concentration of IBU in solution was determined by HPLC. The study showed that the dissolution rate of IBU can be improved significantly using the mesoporous S224FP carriers due to the conversion of crystalline IBU into the amorphous form. Both of the loading factors affected the IBU dissolution kinetics. Due to the molecular interaction between the IBU and NS2 carriers, the loading factors had little effects on the drug release kinetics with incomplete drug desorption recovery and insignificant dissolution enhancement. Care and extensive evaluation must therefore be taken when mesoporous materials are chosen as carrier delivery systems. PMID:28772509
Surveillance of bacteriological examinations at hospitalization in a pediatric surgical ward.
Ohno, Koichi; Nakamura, Tetsuro; Azuma, Takashi; Yoshida, Tatsuyuki; Yamada, Hiroto; Hayashi, Hiroaki; Masahata, Kazunori
2008-08-01
Bacteriological examinations at hospitalization were monitored to identify carriers of pathogenic bacteria and prevent the outbreak of nosocomial and postoperative infections. In 557 patients, bacteriological examinations were performed within 48 hours after hospitalization. All people were instructed to wash their hands before and after treating carriers of methicillin-resistant Staphylococcus aureus (MRSA), methicillin-resistant Staphylococcus epidermidis (MRSE), and/or Pseudomonas aeruginosa (PA). The disposal of stool and urine of carriers was segregated instead of administration of sensitive antibiotics. The 1176 samples comprised 557 throat swabs, 532 stool samples, and 87 other samples. At hospitalization, 9.2% of the patients were carriers of MRSA; 22.3% of the patients were carriers of MRSA, MRSE, PA, and/or other pathogenic bacteria. This percentage increased to 29.3% in 352 patients with a history of hospitalization, and 35.2% in 244 patients who were hospitalized within 1 year after previous hospitalization. Nosocomial and postoperative infections did not occur during the study period. Many patients were detected as carriers of pathogenic bacteria at hospitalization. A history of hospitalization was found to be a risk factor for carrying pathogenic bacteria; hospitalization within 1 year after previous hospitalization was a high-risk factor.
Comparison of methods to detect Pasteurella multocida in carrier waterfowl
Samuel, M.D.; Shadduck, D.J.; Goldberg, Diana R.; Johnson, W.P.
2003-01-01
We conducted laboratory challenge trials using mallard ducks (Anas platyrhynchos) to compare methods for detecting carriers of Pasteurella multocida, the bacterium that causes avian cholera, in wild birds. Birds that survived the initial infection were euthanized at 2-4 wk intervals up to 14 wk post challenge. Isolates of P. multocida were obtained at necropsy from 23% of the birds that survived initial infection. We found that swab samples (oral, cloacal, nasal, eye, and leg joint) were most effective for detecting carrier birds up to 14 wk post infection. No detectable differences in isolation were observed for samples stored in either 10% dimethysulfoxide or brain heart infusion broth. The frequency of detecting carriers in our challenge trials appeared to be related to mortality rates observed during the trial, but was not related to a number of other factors including time after challenge, time delays in collecting tissues postmortem, and route of infection. In our trials, there was little association between antibody levels and carrier status. We concluded that swabs samples collected from recently dead birds, stored in liquid nitrogen, and processed using selective broth provide a feasible field method for detecting P. multocida carriers in wild waterfowl.
Egorov, Oleg B.; O'Hara, Matthew J.; Grate, Jay W.; Chandler, Darrell P.; Brockman, Fred J.; Bruckner-Lea, Cynthia J.
2000-01-01
The invention encompasses systems for column-based separations, methods of packing and unpacking columns and methods of separating components of samples. In one aspect, the invention includes a method of packing and unpacking a column chamber, comprising: a) packing a matrix material within a column chamber to form a packed column; and b) after the packing, unpacking the matrix material from the column chamber without moving the column chamber. In another aspect, the invention includes a system for column-based separations, comprising: a) a fluid passageway, the fluid passageway comprising a column chamber and a flow path in fluid communication with the column chamber, the flow path being obstructed by a retaining material permeable to a carrier fluid and impermeable to a column matrix material suspended in the carrier fluid, the flow path extending through the column chamber and through the retaining material, the flow path being configured to form a packed column within the column chamber when a suspension of the fluid and the column matrix material is flowed along the flow path; and b) the fluid passageway extending through a valve intermediate the column chamber and the retaining material.
Egorov, Oleg B.; O'Hara, Matthew J.; Grate, Jay W.; Chandler, Darrell P.; Brockman, Fred J.; Bruckner-Lea, Cynthia J.
2006-02-21
The invention encompasses systems for column-based separations, methods of packing and unpacking columns and methods of separating components of samples. In one aspect, the invention includes a method of packing and unpacking a column chamber, comprising: a) packing a matrix material within a column chamber to form a packed column; and b) after the packing, unpacking the matrix material from the column chamber without moving the column chamber. In another aspect, the invention includes a system for column-based separations, comprising: a) a fluid passageway, the fluid passageway comprising a column chamber and a flow path in fluid communication with the column chamber, the flow path being obstructed by a retaining material permeable to a carrier fluid and impermeable to a column matrix material suspended in the carrier fluid, the flow path extending through the column chamber and through the retaining material, the flow path being configured to form a packed column within the column chamber when a suspension of the fluid and the column matrix material is flowed along the flow path; and b) the fluid passageway extending through a valve intermediate the column chamber and the retaining material.
Egorov, Oleg B.; O'Hara, Matthew J.; Grate, Jay W.; Chandler, Darrell P.; Brockman, Fred J.; Bruckner-Lea, Cynthia J.
2004-08-24
The invention encompasses systems for column-based separations, methods of packing and unpacking columns and methods of separating components of samples. In one aspect, the invention includes a method of packing and unpacking a column chamber, comprising: a) packing a matrix material within a column chamber to form a packed column; and b) after the packing, unpacking the matrix material from the column chamber without moving the column chamber. In another aspect, the invention includes a system for column-based separations, comprising: a) a fluid passageway, the fluid passageway comprising a column chamber and a flow path in fluid communication with the column chamber, the flow path being obstructed by a retaining material permeable to a carrier fluid and impermeable to a column matrix material suspended in the carrier fluid, the flow path extending through the column chamber and through the retaining material, the flow path being configured to form a packed column within the column chamber when a suspension of the fluid and the column matrix material is flowed along the flow path; and b) the fluid passageway extending through a valve intermediate the column chamber and the retaining material.
Adiponectin isoform patterns in ethnic-specific ADIPOQ mutation carriers: The IRAS Family Study
Tabb, Keri L.; Gao, Chuan; Hicks, Pamela J.; Hawkins, Gregory A.; Rotter, Jerome I.; da Chen, Yii-Der I; Guo, Xiuqing; Norris, Jill M.; Lorenzo, Carlos; Freedman, Barry I.; Bowden, Donald W.; Palmer, Nicholette D.
2017-01-01
Objective Adiponectin is found in human serum in three groups of multimers (high, medium, and low molecular weight). Previously, we reported two ethnic-specific variants in ADIPOQ, G45R (Hispanic Americans) and R55C (African Americans). Although carriers of both variants had mean adiponectin levels ≤20% of those of non-carriers, they were not clinically different from non-carriers. To compare carriers of both variants and non-carriers, relative quantification of adiponectin isoforms to total adiponectin was performed on serum samples. Methods The multimeric patterns of serum adiponectin in G45R carriers (n=23), R55C carriers (n=3), and Hispanic and African American non-carriers (n=84 and 44, respectively) from the IRAS Family Study were explored using native western blotting and densitometry. Results Serum samples from carriers showed an absence of the high molecular weight (HMW) isoform and a marked reduction in the medium molecular weight isoform but an approximate two-fold increase in the amount of the low molecular weight isoform (LMW). Thus, individuals making only LMW adiponectin are metabolically normal. Conclusions The results contrast with the proposed biological importance of the HMW multimer. This suggests that the LMW isoform may functionally compensate for some of the loss/reduction of the higher-order multimers in carriers of the G45R and R55C mutations. PMID:28643464
Multiple doping of silicon-germanium alloys for thermoelectric applications
NASA Technical Reports Server (NTRS)
Fleurial, Jean-Pierre; Vining, Cronin B.; Borshchevsky, Alex
1989-01-01
It is shown that heavy doping of n-type Si/Ge alloys with phosphorus and arsenic (V-V doping interaction) by diffusion leads to a significant enhancement of their carrier concentration and possible improvement of the thermoelectric figure of merit. High carrier concentrations were achieved by arsenic doping alone, but for a same doping level higher carrier mobilities and lower resistivities are obtained through phosphorus doping. By combining the two dopants with the proper diffusion treatments, it was possible to optimize the different properties, obtaining high carrier concentration, good carrier mobility and low electrical resistivity. Similar experiments, using the III-V doping interaction, were conducted on boron-doped p-type samples and showed the possibility of overcompensating the samples by diffusing arsenic, in order to get n-type behavior.
Code of Federal Regulations, 2010 CFR
2010-07-01
... accounting system do in relation to common carrier transportation? 301-72.100 Section 301-72.100 Public... for Common Carrier Transportation § 301-72.100 What must my travel accounting system do in relation to... claims accounting systems with common carrier transportation documents and data for audit purposes; (c...
Sigler, K; Gásková, D; Chládková, K; Knebl, R; Wimmer, T; Vacata, V; Gebel, J
2003-01-01
An easy-to construct, easy-to-operate standardized system was developed for determining the residual biological contamination of surgical instruments, endoscopes and other medical appliances subjected to hospital cleansing and/or disinfection. It consists of standard-sized pieces of glass, metal or endoscope plastic--dirt carriers--either bare or enclosed in truncated Eppendorf caps to simulate hard-to-access conditions. The surface of the carriers is covered with model dirt simulating biological contamination and the carriers are then affixed to sturdy metal holders. Conventional model dirt were found to peel or flake off the carrier surface, lowering the precision of residual soil determination. A newly developed model dirt consisting of liver mash, lactose and sunflower oil and exhibiting low tendency to peel off surfaces was therefore used. The whole setup was subjected to chemical or enzymic cleansing programs at elevated temperature in hospital washer-disinfectors of two types, and the residual dirt after cleansing was determined by three methods. The method using toxicant-doped dirt that quenches the luminescence of an indicator bacterium Photobacterium phosphoreum gave satisfactory data under laboratory conditions but with hospital-washed samples it exhibited excessive fluctuations caused by bacterium--dirt interactions and by physical influences. Both other methods gave better results but displayed some process sensitivity. The luciferin-luciferase-based ATP bioluminescence assay sometimes gave low or even negative dirt level values and showed a low effect of reduced dirt accessibility on cleansing of metal carriers. The Bradford protein assay showed about equal cleansing efficiency for both easily and poorly accessible carriers after enzymic cleansing. Our system can be used for determining low levels of residual contamination of medical appliances after cleansing/disinfection and assessing the efficiency of commercial washer-disinfectors; its efficiency can be further increased by using a cleansing process-insensitive method for soil detection and quantification.
Miniature multichannel biotelemeter system
NASA Technical Reports Server (NTRS)
Carraway, J. B.; Sumida, J. T. (Inventor)
1974-01-01
A miniature multichannel biotelemeter system is described. The system includes a transmitter where signals from different sources are sampled to produce a wavetrain of pulses. The transmitter also separates signals by sync pulses. The pulses amplitude modulate a radio frequency carrier which is received at a receiver unit. There the sync pulses are detected by a demultiplexer which routes the pulses from each different source to a separate output channel where the pulses are used to reconstruct the signals from the particular source.
NASA Astrophysics Data System (ADS)
Stephens, A. W.; Green, M. A.
1996-10-01
A method for measuring minority-carrier mobility using microwave-detected photoconductance decay without requiring bulk lifetime, estimates is presented. Three different measurements on a single sample yield values for surface recombination velocity, bulk lifetime, and diffusivity. For each measurement the surface conditions of the sample are changed, allowing extraction of different parameters. The usefulness of 0.08 molar ethanol/iodine solution as a means of achieving such good surface passivation is demonstrated. The following procedure was used to achieve high surface recombination. A CF4 plasma surface etch was shown to achieve the same level of surface damage as mechanical abrasion. The advantage of the new method is that it completely eliminates the chance of breaking samples during the abrasion process, which is of particular advantage for thin samples. The new experimental method for minority-carrier mobility measurement is evaluated using carrier lifetime measurements made on a commercially available Leo Giken ``Wafer-τ'' lifetime tester.
On the hitchhiker Robot Operated Materials Processing System: Experiment data system
NASA Technical Reports Server (NTRS)
Kizhner, Semion; Jenstrom, Del
1995-01-01
The Space Shuttle Discovery STS-64 mission carried the first American autonomous robot into space, the Robot Operated Materials Processing System (ROMPS). On this mission ROMPS was the only Hitchhiker experiment and had a unique opportunity to utilize all Hitchhiker space carrier capabilities. ROMPS conducted rapid thermal processing of the one hundred semiconductor material samples to study how micro gravity affects the resulting material properties. The experiment was designed, built and operated by a small GSFC team in cooperation with industry and university based principal investigators who provided the material samples and data interpretation. ROMPS' success presents some valuable lessons in such cooperation, as well as in the utilization of the Hitchhiker carrier for complex applications. The motivation of this paper is to share these lessons with the scientific community interested in attached payload experiments. ROMPS has a versatile and intelligent material processing control data system. This paper uses the ROMPS data system as the guiding thread to present the ROMPS mission experience. It presents an overview of the ROMPS experiment followed by considerations of the flight and ground data subsystems and their architecture, data products generation during mission operations, and post mission data utilization. It then presents the lessons learned from the development and operation of the ROMPS data system as well as those learned during post-flight data processing.
Junsomboon, Jaroon; Jakmunee, Jaroon
2008-07-15
A simple flow injection system using three 3-way solenoid valves as an electric control injection valve and with a simple home-made chloride ion selective electrode based on Ag/AgCl wire as a sensor for determination of water soluble chloride in admixtures and aggregates for cement has been developed. A liquid sample or an extract was injected into a water carrier stream which was then merged with 0.1M KNO(3) stream and flowed through a flow cell where the solution will be in contact with the sensor, producing a potential change recorded as a peak. A calibration graph in range of 10-100 mg L(-1) was obtained with a detection limit of 2 mg L(-1). Relative standard deviations for 7 replicates injecting of 20, 60 and 90 mg L(-1) chloride solutions were 1.0, 1.2 and 0.6%, respectively. Sample throughput of 60 h(-1) was achieved with the consumption of 1 mL each of electrolyte solution and water carrier. The developed method was validated by the British Standard methods.
DNA Differential Diagnosis of Taeniasis and Cysticercosis by Multiplex PCR
Yamasaki, Hiroshi; Allan, James C.; Sato, Marcello Otake; Nakao, Minoru; Sako, Yasuhito; Nakaya, Kazuhiro; Qiu, Dongchuan; Mamuti, Wulamu; Craig, Philip S.; Ito, Akira
2004-01-01
Multiplex PCR was established for differential diagnosis of taeniasis and cysticercosis, including their causative agents. For identification of the parasites, multiplex PCR with cytochrome c oxidase subunit 1 gene yielded evident differential products unique for Taenia saginata and Taenia asiatica and for American/African and Asian genotypes of Taenia solium with molecular sizes of 827, 269, 720, and 984 bp, respectively. In the PCR-based detection of tapeworm carriers using fecal samples, the diagnostic markers were detected from 7 of 14 and 4 of 9 T. solium carriers from Guatemala and Indonesia, respectively. Test sensitivity may have been reduced by the length of time (up to 12 years) that samples were stored and/or small sample volumes (ca. 30 to 50 mg). However, the diagnostic markers were detected by nested PCR in five worm carriers from Guatemalan cases that were found to be negative by multiplex PCR. It was noteworthy that a 720 bp-diagnostic marker was detected from a T. solium carrier who was egg-free, implying that it is possible to detect worm carriers and treat before mature gravid proglottids are discharged. In contrast to T. solium carriers, 827-bp markers were detected by multiplex PCR in all T. saginata carriers. The application of the multiplex PCR would be useful not only for surveillance of taeniasis and cysticercosis control but also for the molecular epidemiological survey of these cestode infections. PMID:14766815
Colonization sites in carriers of ESBL-producing Gram-negative bacteria.
van Prehn, Joffrey; Kaiser, Anna M; van der Werff, Suzanne D; van Mansfeld, Rosa; Vandenbroucke-Grauls, Christina M J E
2018-01-01
The distribution of Extended-Spectrum Beta-Lactamase-producing Gram-negative bacteria (ESBL-GNB) colonization sites is relevant for infection control guidelines on detection and follow-up of colonization. We questioned whether it is possible to rely solely on rectal swab culture for follow-up of ESBL-GNB colonization. We retrospectively assessed ESBL-GNB colonization sites in patients in a tertiary hospital in the Netherlands. The Laboratory Information Management System was queried for all bacterial cultures obtained between January 2012 and August 2016. All patients with one or more cultures positive for ESBL-GNB were identified and the distribution of ESBL-GNB positive sample sites was assessed. A subgroup analysis was performed on patients for whom at least one rectal swab specimen was available. We identified 1011 ESBL-GNB carriers with 16,578 specimens for analysis. ESBL-GNB were most frequently isolated from the rectum (506/1011), followed by the urogenital (414/1011) and respiratory tract (142/1011), and pus (136/1011). For 588 patients at least one rectal swab specimen was available. In this subgroup, ESBL-GNB colonization was detected only in the rectum in 55.4% (326/588) of patients, in 30.6% (180/588) in the rectum and a different culture site, and in 13.9% (82/588) no rectal colonization was detected. Rectal colonization with ESBL-GNB was detected in 86% of ESBL-GNB carriers. However, in 14% of ESBL-GNB carriers we did not detect rectal colonization. Therefore, samples taken for follow-up of colonization with multi-drug resistant Gram-negative bacteria (MDR-GNB) should ideally also include samples from the site where the MDR-GNB was initially found.
Method for detecting organic contaminants in water supplies
Dooley, K.J.; Barrie, S.L.; Buttner, W.J.
1999-08-24
A system is described for detecting organic contaminants in water supplies. A sampling unit is employed which includes a housing having at least one opening therein and a tubular member positioned within the housing having a central passageway surrounded by a side wall. The side wall is made of a composition designed to absorb the contaminants. In use, the sampling unit is immersed in a water supply. The water supply contacts the tubular member through the opening in the housing, with any contaminants being absorbed into the side wall of the tubular member. A carrier gas is then passed through the central passageway of the tubular member. The contaminants will diffuse out of the side wall and into the central passageway where they will subsequently combine with the carrier gas, thereby yielding a gaseous product. The gaseous product is then analyzed to determine the amount and type of contaminants therein. 5 figs.
Method for detecting organic contaminants in water supplies
Dooley, Kirk J.; Barrie, Scott L.; Buttner, William J.
1999-01-01
A system for detecting organic contaminants in water supplies. A sampling unit is employed which includes a housing having at least one opening therein and a tubular member positioned within the housing having a central passageway surrounded by a side wall. The side wall is made of a composition designed to absorb the contaminants. In use, the sampling unit is immersed in a water supply. The water supply contacts the tubular member through the opening in the housing, with any contaminants being absorbed into the side wall of the tubular member. A carrier gas is then passed through the central passageway of the tubular member. The contaminants will diffuse out of the side wall and into the central passageway where they will subsequently combine with the carrier gas, thereby yielding a gaseous product. The gaseous product is then analyzed to determine the amount and type of contaminants therein.
Joint Cost, Production Technology and Output Disaggregation in Regulated Motor Carriers
DOT National Transportation Integrated Search
1978-11-01
The study uses a sample of 252 Class I Instruction 27 Motor Carriers (Instruction 27 carriers earned at least 75 percent of their revenues from intercity transportation of general commodities over a three year period) of general freight that existed ...
Forrest, Daina; Delatolla, Robert; Kennedy, Kevin
2016-01-01
Increasingly stricter ammonia and nitrogen release regulations with respect to wastewater effluents are creating a need for tertiary treatment systems. The moving bed biofilm reactor (MBBR) is being considered as an upgrade option for an increasing number of wastewater treatment facilities due to its small footprint and ease of operation. Despite the MBBRs creation as a system to remove nitrogen, recent research on MBBR systems showing that the system's performance is directly related to carrier surface area and is irrespective of carrier shape and type has been performed exclusively on chemical oxygen demand (COD) removal systems. Furthermore, the influence of carrier type on the solids produced by MBBR systems has also been exclusively studied for COD removal systems. This work investigates the effects of three specific carrier types on ammonia removal rates, biofilm morphology, along with solids production and settleability of tertiary nitrifying MBBR systems. The study concludes that carrier type has no significant effect on tertiary nitrifying MBBR system performance under steady, moderate loading conditions. The research does however highlight the propensity of greater surface area to volume carriers to become clogged under high loading conditions and that the high surface area carriers investigated in this study required longer adjustment periods to changes in loading after becoming clogged.
Wang, Hsiang-Chen; Chen, Meng-Chu; Lin, Yen-Sheng; Lu, Ming-Yen; Lin, Kuang-I; Cheng, Yung-Chen
2017-11-09
The features of eight-period In 0.2 Ga 0.8 N/GaN quantum wells (QWs) with silicon (Si) doping in the first two to five quantum barriers (QBs) in the growth sequence of blue light-emitting diodes (LEDs) are explored. Epilayers of QWs' structures are grown on 20 pairs of In 0.02 Ga 0.98 N/GaN superlattice acting as strain relief layers (SRLs) on patterned sapphire substrates (PSSs) by a low-pressure metal-organic chemical vapor deposition (LP-MOCVD) system. Temperature-dependent photoluminescence (PL) spectra, current versus voltage (I-V) curves, light output power versus injection current (L-I) curves, and images of high-resolution transmission electron microscopy (HRTEM) of epilayers are measured. The consequences show that QWs with four Si-doped QBs have larger carrier localization energy (41 meV), lower turn-on (3.27 V) and breakdown (- 6.77 V) voltages, and higher output power of light of blue LEDs at higher injection current than other samples. Low barrier height of QBs in a four-Si-doped QB sample results in soft confinement potential of QWs and lower turn-on and breakdown voltages of the diode. HRTEM images give the evidence that this sample has relatively diffusive interfaces of QWs. Uniform spread of carriers among eight QWs and superior localization of carriers in each well are responsible for the enhancement of light output power, in particular, for high injection current in the four-Si-doped QB sample. The results demonstrate that four QBs of eight In 0.2 Ga 0.8 N/GaN QWs with Si doping not only reduce the quantum-confined Stark effect (QCSE) but also improve the distribution and localization of carriers in QWs for better optical performance of blue LEDs.
NASA Astrophysics Data System (ADS)
Wang, Hsiang-Chen; Chen, Meng-Chu; Lin, Yen-Sheng; Lu, Ming-Yen; Lin, Kuang-I.; Cheng, Yung-Chen
2017-11-01
The features of eight-period In0.2Ga0.8N/GaN quantum wells (QWs) with silicon (Si) doping in the first two to five quantum barriers (QBs) in the growth sequence of blue light-emitting diodes (LEDs) are explored. Epilayers of QWs' structures are grown on 20 pairs of In0.02Ga0.98N/GaN superlattice acting as strain relief layers (SRLs) on patterned sapphire substrates (PSSs) by a low-pressure metal-organic chemical vapor deposition (LP-MOCVD) system. Temperature-dependent photoluminescence (PL) spectra, current versus voltage ( I- V) curves, light output power versus injection current ( L- I) curves, and images of high-resolution transmission electron microscopy (HRTEM) of epilayers are measured. The consequences show that QWs with four Si-doped QBs have larger carrier localization energy (41 meV), lower turn-on (3.27 V) and breakdown (- 6.77 V) voltages, and higher output power of light of blue LEDs at higher injection current than other samples. Low barrier height of QBs in a four-Si-doped QB sample results in soft confinement potential of QWs and lower turn-on and breakdown voltages of the diode. HRTEM images give the evidence that this sample has relatively diffusive interfaces of QWs. Uniform spread of carriers among eight QWs and superior localization of carriers in each well are responsible for the enhancement of light output power, in particular, for high injection current in the four-Si-doped QB sample. The results demonstrate that four QBs of eight In0.2Ga0.8N/GaN QWs with Si doping not only reduce the quantum-confined Stark effect (QCSE) but also improve the distribution and localization of carriers in QWs for better optical performance of blue LEDs.
Ultrafast carrier dynamics in band edge and broad deep defect emission ZnSe nanowires
NASA Astrophysics Data System (ADS)
Othonos, Andreas; Lioudakis, Emmanouil; Philipose, U.; Ruda, Harry E.
2007-12-01
Ultrafast carrier dynamics of ZnSe nanowires grown under different growth conditions have been studied. Transient absorption measurements reveal the dependence of the competing effects of state filling and photoinduced absorption on the probed energy states. The relaxation of the photogenerated carriers occupying defect states in the stoichiometric and Se-rich samples are single exponentials with time constants of 3-4ps. State filling is the main contribution for probe energies below 1.85eV in the Zn-rich grown sample. This ultrafast carrier dynamics study provides an important insight into the role that intrinsic point defects play in the observed photoluminescence from ZnSe nanowires.
Influence of Thermal Annealing on Free Carrier Concentration in (GaN) 1–x(ZnO) x Semiconductors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Huafeng; Sklute, Elizabeth C.; Lehuta, Keith A.
It has been previously demonstrated that the efficiency of (GaN) 1–x(ZnO) x semiconductors for solar water splitting can be improved by thermal annealing, though the origin of this improvement was not resolved. In the present work, it is shown that annealing reduces the free carrier (electron) concentration of (GaN) 1–x(ZnO) x. The time-, temperature-, and atmosphere-dependent changes were followed through two simple techniques: indirect diffuse reflectance measurements from 0.5 to 3.0 eV which show very high sensitivity to the free carrier response at the lowest energies and EPR measurements which directly probe the number of unpaired electrons. For the thermalmore » annealing of investigated compositions, it is found that temperatures of 250 °C and below do not measurably change the free carrier concentration, a gradual reduction of the free carrier concentration occurs over a time period of many hours at 350 °C, and the complete elimination of free carriers happens within an hour at 550 °C. These changes are driven by an oxidative process which is effectively suppressed under actively reducing atmospheres (H 2, NH 3) but which can still occur under nominally inert gases (N 2, Ar). Surprisingly, it is found that the N 2 gas released during thermal oxidation of (GaN) 1–x(ZnO) x samples remains trapped within the solid matrix and is not expelled until temperatures of about 900 °C, a result directly confirmed through neutron pair-distribution fuction (PDF) measurements which show a new peak at the 1.1 Å bond length of molecular nitrogen after annealing. Preliminary comparative photoelectrochemical (PEC) measurements of the influence of free carrier concentration on photoactivity for water oxidation were carried out for a sample with x = 0.64. Samples annealed to eliminate free carriers exhibited no photoactivity for water oxidation, while a complex dependence on carrier concentration was observed for samples with intermediate free carrier concentrations. The methods demonstrated here provide an important approach for quantifying (and controlling) the carrier concentrations of semiconductors which are only available in the form of loose powders, as is commonly the case for oxynitride compounds.« less
Influence of Thermal Annealing on Free Carrier Concentration in (GaN) 1–x(ZnO) x Semiconductors
Huang, Huafeng; Sklute, Elizabeth C.; Lehuta, Keith A.; ...
2017-09-13
It has been previously demonstrated that the efficiency of (GaN) 1–x(ZnO) x semiconductors for solar water splitting can be improved by thermal annealing, though the origin of this improvement was not resolved. In the present work, it is shown that annealing reduces the free carrier (electron) concentration of (GaN) 1–x(ZnO) x. The time-, temperature-, and atmosphere-dependent changes were followed through two simple techniques: indirect diffuse reflectance measurements from 0.5 to 3.0 eV which show very high sensitivity to the free carrier response at the lowest energies and EPR measurements which directly probe the number of unpaired electrons. For the thermalmore » annealing of investigated compositions, it is found that temperatures of 250 °C and below do not measurably change the free carrier concentration, a gradual reduction of the free carrier concentration occurs over a time period of many hours at 350 °C, and the complete elimination of free carriers happens within an hour at 550 °C. These changes are driven by an oxidative process which is effectively suppressed under actively reducing atmospheres (H 2, NH 3) but which can still occur under nominally inert gases (N 2, Ar). Surprisingly, it is found that the N 2 gas released during thermal oxidation of (GaN) 1–x(ZnO) x samples remains trapped within the solid matrix and is not expelled until temperatures of about 900 °C, a result directly confirmed through neutron pair-distribution fuction (PDF) measurements which show a new peak at the 1.1 Å bond length of molecular nitrogen after annealing. Preliminary comparative photoelectrochemical (PEC) measurements of the influence of free carrier concentration on photoactivity for water oxidation were carried out for a sample with x = 0.64. Samples annealed to eliminate free carriers exhibited no photoactivity for water oxidation, while a complex dependence on carrier concentration was observed for samples with intermediate free carrier concentrations. The methods demonstrated here provide an important approach for quantifying (and controlling) the carrier concentrations of semiconductors which are only available in the form of loose powders, as is commonly the case for oxynitride compounds.« less
Optimization of territory control of the mail carrier by using Hungarian methods
NASA Astrophysics Data System (ADS)
Supian, S.; Wahyuni, S.; Nahar, J.; Subiyanto
2018-03-01
In this paper, the territory control of the mail carrier from the central post office Bandung in delivering the package to the destination location was optimized by using Hungarian method. Sensitivity analysis against data changes that may occur was also conducted. The sampled data in this study are the territory control of 10 mail carriers who will be assigned to deliver mail package to 10 post office delivery centers in Bandung. The result of this research is the combination of territory control optimal from 10 mail carriers as follows: mail carrier 1 to Cikutra, mail carrier 2 to Ujung Berung, mail carrier 3 to Dayeuh Kolot, mail carrier 4 to Padalarang, mail carrier 5 to Situ Saeur, mail carrier 6 to Cipedes, mail carrier 7 to Cimahi, mail carrier 8 to Soreang, mail carrier 9 to Asia-Afrika, mail carrier 10 to Cikeruh. Based on this result, manager of the central post office Bandung can make optimal decisions to assign tasks to their mail carriers.
Automated two-dimensional interface for capillary gas chromatography
Strunk, M.R.; Bechtold, W.E.
1996-02-20
A multidimensional gas chromatograph (GC) system is disclosed which has wide bore capillary and narrow bore capillary GC columns in series and has a novel system interface. Heart cuts from a high flow rate sample, separated by a wide bore GC column, are collected and directed to a narrow bore GC column with carrier gas injected at a lower flow compatible with a mass spectrometer. A bimodal six-way valve is connected with the wide bore GC column outlet and a bimodal four-way valve is connected with the narrow bore GC column inlet. A trapping and retaining circuit with a cold trap is connected with the six-way valve and a transfer circuit interconnects the two valves. The six-way valve is manipulated between first and second mode positions to collect analyte, and the four-way valve is manipulated between third and fourth mode positions to allow carrier gas to sweep analyte from a deactivated cold trap, through the transfer circuit, and then to the narrow bore GC capillary column for separation and subsequent analysis by a mass spectrometer. Rotary valves have substantially the same bore width as their associated columns to minimize flow irregularities and resulting sample peak deterioration. The rotary valves are heated separately from the GC columns to avoid temperature lag and resulting sample deterioration. 3 figs.
Automated two-dimensional interface for capillary gas chromatography
Strunk, Michael R.; Bechtold, William E.
1996-02-20
A multidimensional gas chromatograph (GC) system having wide bore capillary and narrow bore capillary GC columns in series and having a novel system interface. Heart cuts from a high flow rate sample, separated by a wide bore GC column, are collected and directed to a narrow bore GC column with carrier gas injected at a lower flow compatible with a mass spectrometer. A bimodal six-way valve is connected with the wide bore GC column outlet and a bimodal four-way valve is connected with the narrow bore GC column inlet. A trapping and retaining circuit with a cold trap is connected with the six-way valve and a transfer circuit interconnects the two valves. The six-way valve is manipulated between first and second mode positions to collect analyte, and the four-way valve is manipulated between third and fourth mode positions to allow carrier gas to sweep analyte from a deactivated cold trap, through the transfer circuit, and then to the narrow bore GC capillary column for separation and subsequent analysis by a mass spectrometer. Rotary valves have substantially the same bore width as their associated columns to minimize flow irregularities and resulting sample peak deterioration. The rotary valves are heated separately from the GC columns to avoid temperature lag and resulting sample deterioration.
Space Station fluid management logistics
NASA Technical Reports Server (NTRS)
Dominick, Sam M.
1990-01-01
Viewgraphs and discussion on space station fluid management logistics are presented. Topics covered include: fluid management logistics - issues for Space Station Freedom evolution; current fluid logistics approach; evolution of Space Station Freedom fluid resupply; launch vehicle evolution; ELV logistics system approach; logistics carrier configuration; expendable fluid/propellant carrier description; fluid carrier design concept; logistics carrier orbital operations; carrier operations at space station; summary/status of orbital fluid transfer techniques; Soviet progress tanker system; and Soviet propellant resupply system observations.
Hybrid electronic/optical synchronized chaos communication system.
Toomey, J P; Kane, D M; Davidović, A; Huntington, E H
2009-04-27
A hybrid electronic/optical system for synchronizing a chaotic receiver to a chaotic transmitter has been demonstrated. The chaotic signal is generated electronically and injected, in addition to a constant bias current, to a semiconductor laser to produce an optical carrier for transmission. The optical chaotic carrier is photodetected to regenerate an electronic signal for synchronization in a matched electronic receiver The system has been successfully used for the transmission and recovery of a chaos masked message that is added to the chaotic optical carrier. Past demonstrations of synchronized chaos based, secure communication systems have used either an electronic chaotic carrier or an optical chaotic carrier (such as the chaotic output of various nonlinear laser systems). This is the first electronic/optical hybrid system to be demonstrated. We call this generation of a chaotic optical carrier by electronic injection.
The theory, design, and operation of the suppressed carrier data-aided tracking receiver
NASA Technical Reports Server (NTRS)
Simon, M. K.; Springett, J. C.
1973-01-01
A viable, efficient, and easily mechanized carrier regenerating receiver for use in suppressed carrier-tracking system is described. The receiver referred to as a data-aided receiver (DAR) incorporates a data-aided loop (DAL) which provides the required carrier reference signal. The DAL employs the principle of decision feedback and as such is more efficient than other forms of suppressed carrier-tracking loops. The analysis, design, and implementation of the DAR are covered in detail. Performance comparisons and mechanization tradeoffs are made, wherever possible, with discrete carrier systems and other suppressed carrier systems presently in use. Experimental performance verification is given throughout in support of the theory presented.
Synthesis and characterization of Cr doped CoFe2O4
NASA Astrophysics Data System (ADS)
Verma, Kavita; Patel, K. R.; Ram, Sahi; Barbar, S. K.
2016-05-01
Polycrystalline samples of pure and Cr-doped cobalt ferrite (CoFe2O4 and CoCrFeO4) were prepared by solid state reaction route method. X-ray diffraction pattern infers that both the samples are in single phase with Fd3m space group. Slight reduction in the lattice parameter of CoCrFeO4 has been observed as compared to CoFe2O4. The dielectric dispersion has been explained on the basis of Fe2+ ↔ Fe3+ hopping mechanism. The polarizations at lower frequencies are mainly attributed to electronic exchange between Fe2+ ↔ Fe3+ ions on the octahedral site in the ferrite lattice. In the present system a part from n-type charge carrier (Fe3+/Fe2+), the presence of (Co3+/Co2+) ions give rise to p-type charge carrier. Therefore in addition to n-type charge carrier, the local displacement of p-type charge carrier in direction of external electric field also contributes to net polarization. However, the dielectric constant and loss tangent of CoCrFeO4 are found to be lower than CoFe2O4 and is attributed to the availability of ferrous ion. CoCrFeO4 have less amount of ferrous ion available for polarization as compared to that of CoFe2O4. The impedance spectra reveal a grain interior contribution to the conduction process.
Hurley, J.P.; McCollor, D.P.; Selle, S.J.
1994-07-26
A long duration ash probe includes a pressure shell connected to a port in a combustor with a sample coupon mounted on a retractable carriage so as to retract the sample coupon within the pressure shell during soot blowing operation of the combustor. A valve mounted at the forward end of the pressure shell is selectively closeable to seal the sample coupon within the shell, and a heating element in the shell is operable to maintain the desired temperature of the sample coupon while retracted within the shell. The carriage is operably mounted on a pair of rails within the shell for longitudinal movement within the shell. A hollow carrier tube connects the hollow cylindrical sample coupon to the carriage, and extends through the carriage and out the rearward end thereof. Air lines are connected to the rearward end of the carrier tube and are operable to permit coolant to pass through the air lines and thence through the carrier tube to the sample coupon so as to cool the sample coupon. 8 figs.
Hurley, John P.; McCollor, Don P.; Selle, Stanley J.
1994-01-01
A long duration ash probe includes a pressure shell connected to a port in a combustor with a sample coupon mounted on a retractable carriage so as to retract the sample coupon within the pressure shell during sootblowing operation of the combustor. A valve mounted at the forward end of the pressure shell is selectively closeable to seal the sample coupon within the shell, and a heating element in the shell is operable to maintain the desired temperature of the sample coupon while retracted within the shell. The carriage is operably mounted on a pair of rails within the shell for longitudinal movement within the shell. A hollow carrier tube connects the hollow cylindrical sample coupon to the carriage, and extends through the carriage and out the rearward end thereof. Air lines are connected to the rearward end of the carrier tube and are operable to permit coolant to pass through the air lines and thence through the carrier tube to the sample coupon so as to cool the sample coupon.
DNA transfer-a never ending story. A study on scenarios involving a second person as carrier.
Helmus, Janine; Bajanowski, Thomas; Poetsch, Micaela
2016-01-01
The transfer of DNA directly from one item to another has been shown in many studies with elaborate discussions on the nature of the DNA donor as well as material and surface of the items or surrounding features. Every DNA transfer scenario one can imagine seems to be possible. This evokes more and more intricate scenarios proposed by lawyers or attorneys searching for an explanation of the DNA of a certain person on a distinct item with impact on a crime. At court, the forensic genetic scientist has to comment on the probability of these scenarios thus calling for extensive studies on such settings. Here, the possibility of an involvement of a second person as a carrier of the donor's DNA in a variety of different scenarios including three pairs of people and two kinds of items (textiles and plastic bags) was investigated. All transfer settings were executed with and without gloves on the carrier's hands. DNA left on the items was isolated and analyzed using the Powerplex® ESX17 kit. In 21 out of 180 samples, all alleles of the donor DNA could be obtained on the second item (12%), on eight samples, the donor's DNA was dominant compared to all other alleles (38% of samples with complete donor profile). Additionally, 51 samples displayed at least more than half of the donor's alleles (28%). The complete DNA profile of the carrier was found in 47 out of 180 samples (42 partial profiles). In summary, it could be shown that a transfer of donor DNA from epithelial cells through a carrier to a second item is possible, even if the carrier does not wear gloves.
Ultrafast carrier thermalization and cooling dynamics in few-layer MoS2.
Nie, Zhaogang; Long, Run; Sun, Linfeng; Huang, Chung-Che; Zhang, Jun; Xiong, Qihua; Hewak, Daniel W; Shen, Zexiang; Prezhdo, Oleg V; Loh, Zhi-Heng
2014-10-28
Femtosecond optical pump-probe spectroscopy with 10 fs visible pulses is employed to elucidate the ultrafast carrier dynamics of few-layer MoS2. A nonthermal carrier distribution is observed immediately following the photoexcitation of the A and B excitonic transitions by the ultrashort, broadband laser pulse. Carrier thermalization occurs within 20 fs and proceeds via both carrier-carrier and carrier-phonon scattering, as evidenced by the observed dependence of the thermalization time on the carrier density and the sample temperature. The n(-0.37 ± 0.03) scaling of the thermalization time with carrier density suggests that equilibration of the nonthermal carrier distribution occurs via non-Markovian quantum kinetics. Subsequent cooling of the hot Fermi-Dirac carrier distribution occurs on the ∼ 0.6 ps time scale via carrier-phonon scattering. Temperature- and fluence-dependence studies reveal the involvement of hot phonons in the carrier cooling process. Nonadiabatic ab initio molecular dynamics simulations, which predict carrier-carrier and carrier-phonon scattering time scales of 40 fs and 0.5 ps, respectively, lend support to the assignment of the observed carrier dynamics.
DOT National Transportation Integrated Search
2014-01-24
The Carrier Safety Measurement System (CSMS) is the Federal Motor Carrier Safety Administrations (FMCSA's) workload prioritization tool. This tool is used to identify carriers with potential safety issues so that they are subject to interventions ...
A Frontal Dopamine System for Reflective Exploratory Behavior
Blanco, Nathaniel J.; Love, Bradley C.; Cooper, Jessica A.; McGeary, John E.; Knopik, Valerie S.; Maddox, W. Todd
2015-01-01
The COMT gene modulates dopamine levels in prefrontal cortex with Met allele carriers having lower COMT enzyme activity and, therefore, higher dopamine levels compared to Val/Val homozygotes. Concordantly, Val/Val homozygotes tend to perform worse and display increased (interpreted as inefficient) frontal activation in certain cognitive tasks. In a sample of 209 participants, we test the hypothesis that Met carriers will be advantaged in a decision-making task that demands sequencing exploratory and exploitive choices to minimize uncertainty about the reward structure in the environment. Previous work suggests that optimal performance depends on limited cognitive resources supported by prefrontal systems. If so, Met carriers should outperform Val/Val homozygotes, particularly under dual-task conditions that tax limited cognitive resources. In accord with these a priori predictions, Met carriers were more resilient in the face of cognitive load, continuing to explore in a sophisticated manner. We fit computational models that embody sophisticated reflective and simple reflexive strategies to further evaluate participants' exploration behavior. The Ideal Actor model reflectively updates beliefs and plans ahead, taking into account the information gained by each choice and making choices that maximize long-term payoffs. In contrast, the Naïve Reinforcement Learning (RL) model instantiates the reflexive account of choice, in which the values of actions are based only on the rewards experienced so far. Its beliefs are updated reflexively in response to observed changes in rewards. Converging with standard analyses, Met carriers were best characterized by the Ideal Actor model, whereas Val/Val homozygotes were best characterized by the Naive RL model, particularly under dual-task conditions. PMID:26004676
NASA Astrophysics Data System (ADS)
Yang, Ching-Mei
1995-01-01
P-i-n diodes containing multiple quantum wells (MQWs) in the i-region are the building blocks for photonic devices. When we apply electric field across these devices and illuminate it with light, photo-carriers are created in the i-region. These carriers escape from the wells and drift toward the electrodes; thus photo-voltage is created. The rise- and decay-times of photo-voltages are related to the transport of carriers. In this dissertation, we present theoretical and experimental studies on carrier transport mechanisms of three shallow MQW GaAs/Al _{x}Ga_{1-x}As p-i-n diodes (x = 0.02, 0.04, 0.08) at various bias voltages. We start with the description of the sample structures and their package. We then present the characteristics of these samples including their transmission spectra and responsivity. We will demonstrate that the over-all high quality of these samples, including a strong exciton resonant absorption, ~100% internal quantum efficiencies and completely depleted i-region at bias between +0.75 V to -5 V bias. In our theoretical studies, we first discuss the possible carrier sweep-out mechanisms and estimate the response times associated with these mechanisms. Based on our theoretical model, we conclude that only the drift times of carriers and enhanced diffusion times are important for shallow MQW p-i-n diodes: at high bias, the fast drift times of electrons and holes control the rise-times; at low bias, the slow drift times of holes and the enhanced diffusion times control the decay-times. We have performed picosecond time-resolved pump/probe electro-absorption measurements on these samples. We then obtained the drift times, effective drift velocities and effective mobilities of electrons and holes for these devices. We find that the carrier effective drift velocities (especially for holes) seemed insensitive to the Al concentration in the barriers (in the range of x = 2% to 8%), even though the x = 2% sample does show an overall faster response time. We think the slight difference of the rise- and decay-times of these devices may also be affected by random differences between the samples.
NASA Astrophysics Data System (ADS)
Li, J.; Tan, L. Z.; Zou, K.; Stabile, A. A.; Seiwell, D. J.; Watanabe, K.; Taniguchi, T.; Louie, Steven G.; Zhu, J.
2016-10-01
In a two-dimensional electron gas, the electron-electron interaction generally becomes stronger at lower carrier densities and renormalizes the Fermi-liquid parameters, such as the effective mass of carriers. We combine experiment and theory to study the effective masses of electrons and holes me* and mh* in bilayer graphene in the low carrier density regime on the order of 1 ×1011c m-2 . Measurements use temperature-dependent low-field Shubnikov-de Haas oscillations observed in high-mobility hexagonal boron nitride supported samples. We find that while me* follows a tight-binding description in the whole density range, mh* starts to drop rapidly below the tight-binding description at a carrier density of n =6 ×1011c m-2 and exhibits a strong suppression of 30% when n reaches 2 ×1011c m-2 . Contributions from the electron-electron interaction alone, evaluated using several different approximations, cannot explain the experimental trend. Instead, the effect of the potential fluctuation and the resulting electron-hole puddles play a crucial role. Calculations including both the electron-electron interaction and disorder effects explain the experimental data qualitatively and quantitatively. This Rapid Communication reveals an unusual disorder effect unique to two-dimensional semimetallic systems.
Investigating enhanced thermoelectric performance of graphene-based nano-structures.
Hossain, Md Sharafat; Huynh, Duc Hau; Jiang, Liming; Rahman, Sharmin; Nguyen, Phuong Duc; Al-Dirini, Feras; Hossain, Faruque; Bahk, Je-Hyeong; Skafidas, Efstratios
2018-03-08
Recently, it has been demonstrated that graphene nano-ribbons (GNRs) exhibit superior thermoelectric performance compared to graphene sheets. However, the underlying mechanism behind this enhancement has not been systematically investigated and significant opportunity remains for further enhancement of the thermoelectric performance of GNRs by optimizing their charge carrier concentration. In this work, we modulate the carrier concentration of graphene-based nano-structures using a gate voltage and investigate the resulting carrier-concentration-dependent thermoelectric parameters using the Boltzmann transport equations. We investigate the effect of energy dependent scattering time and the role of substrate-induced charge carrier fluctuation in optimizing the Seebeck coefficient and power factor. Our approach predicts the scattering mechanism and the extent of the charge carrier fluctuation in different samples and explains the enhancement of thermoelectric performance of GNR samples. Subsequently, we propose a route towards the enhancement of thermoelectric performance of graphene-based devices which can also be applied to other two-dimensional materials.
DOT National Transportation Integrated Search
2017-08-01
This FMCSA-sponsored research investigated the claim that motor carriers have a substantial number of crashes in their own records that are not contained in the Motor Carrier Management Information System (MCMIS) crash file. Based on the results of t...
Signal enhancement using a switchable magnetic trap
Beer, Neil Reginald [Pleasanton, CA
2012-05-29
A system for analyzing a sample including providing a microchannel flow channel; associating the sample with magnetic nanoparticles or magnetic polystyrene-coated beads; moving the sample with said magnetic nanoparticles or magnetic polystyrene-coated beads in the microchannel flow channel; holding the sample with the magnetic nanoparticles or magnetic polystyrene-coated beads in a magnetic trap in the microchannel flow channel; and analyzing the sample obtaining an enhanced analysis signal. An apparatus for analysis of a sample includes magnetic particles connected to the sample, a microchip, a flow channel in the microchip, a source of carrier fluid connected to the flow channel for moving the sample in the flow channel, an electromagnet trap connected to the flow line for selectively magnetically trapping the sample and the magnetic particles, and an analyzer for analyzing the sample.
In-situ generation of carrier gases for scientific analyses on Mars
NASA Technical Reports Server (NTRS)
Finn, J. E.; Sridhar, K. R.
1997-01-01
The search for useful raw materials on planetary surfaces will involve various scientific analyses of soil and rock samples. The devices performing these measurements often require inert carrier gases for moving analytes and purging instrumentation. At present, the carrier or sweep gas must be carried from Earth in a compressed gas cylinder, and so the supply of this depletable resource sets a hard limit on the (flexible) life span of the experiment. If a suitable carrier gas could be produced in-situ, then the scientific return of exploration missions could be extended and enhanced greatly. Many more samples could be analyzed, long-ranging rovers could have independent gas supplies, and designs could have added flexibility with respect to gas consumption.
Trost, Sarah; Diekhof, Esther K; Mohr, Holger; Vieker, Henning; Krämer, Bernd; Wolf, Claudia; Keil, Maria; Dechent, Peter; Binder, Elisabeth B; Gruber, Oliver
2016-10-01
Recent genome-wide association studies have identified MAD1L1 (mitotic arrest deficient-like 1) as a susceptibility gene for bipolar disorder and schizophrenia. The minor allele of the single-nucleotide polymorphism (SNP) rs11764590 in MAD1L1 was associated with bipolar disorder. Both diseases, bipolar disorder and schizophrenia, are linked to functional alterations in the reward system. We aimed at investigating possible effects of the MAD1L1 rs11764590 risk allele on reward systems functioning in healthy adults. A large homogenous sample of 224 young (aged 18-31 years) participants was genotyped and underwent functional magnetic resonance imaging (fMRI). All participants performed the 'Desire-Reason Dilemma' paradigm investigating the neural correlates that underlie reward processing and active reward dismissal in favor of a long-term goal. We found significant hypoactivations of the ventral tegmental area (VTA), the bilateral striatum and bilateral frontal and parietal cortices in response to conditioned reward stimuli in the risk allele carriers compared with major allele carriers. In the dilemma situation, functional connectivity between prefrontal brain regions and the ventral striatum was significantly diminished in the risk allele carriers. Healthy risk allele carriers showed a significant deficit of their bottom-up response to conditioned reward stimuli in the bilateral VTA and striatum. Furthermore, functional connectivity between the ventral striatum and prefrontal areas exerting top-down control on the mesolimbic reward system was reduced in this group. Similar alterations in reward processing and disturbances of prefrontal control mechanisms on mesolimbic brain circuits have also been reported in bipolar disorder and schizophrenia. Together, these findings suggest the existence of an intermediate phenotype associated with MAD1L1.
2015-09-01
Training System ARB Aircraft Recovery Bulletins AR Augmented Reality CAG Carrier Air Group CATCC Carrier Air Traffic Control Center COTS...in integration of an optical lens systems into the aircraft carrier. The current generation of optical lens systems integrated into aircraft ...The use of MOVLAS on an aircraft carrier represents a direct communication link between the LSO and pilot. As a backup landing aid system to
Sugarman, Elaine A; Rohlfs, Elizabeth M; Silverman, Lawrence M; Allitto, Bernice A
2004-01-01
We reviewed CFTR mutation distribution among Hispanic and African American individuals referred for CF carrier screening and compared mutation frequencies to those derived from CF patient samples. Results from CFTR mutation analyses received from January 2001 through September 2003, were analyzed for four populations: Hispanic individuals with a CF diagnosis (n = 159) or carrier screening indication (n = 15,333) and African American individuals with a CF diagnosis (n = 108) or carrier screening indication (n = 8,973). All samples were tested for the same 87 mutation panel. In the Hispanic population, 42 mutations were identified: 30 in the patient population (77.5% detection rate) and 33 among carrier screening referrals. Five mutations not included in the ACMG/ACOG carrier screening panel (3876delA, W1089X, R1066C, S549N, 1949del84) accounted for 7.55% detection in patients and 5.58% among carriers. Among African American referrals, 33 different mutations were identified: 21 in the patient population (74.4% detection) and 23 in the carrier screening population. Together, A559T and 711+5G>A were observed at a detection rate of 3.71% in CF patients and 6.38% in carriers. The mutation distribution seen in both the carrier screening populations reflected an increased frequency of mutations with variable expression such as D1152H, R117H, and L206W. A detailed analysis of CFTR mutation distribution in the Hispanic and African American patient and carrier screening populations demonstrates that a diverse group of mutations is most appropriate for diagnostic and carrier screening in these populations. To best serve the increasingly diverse U.S. population, ethnic-specific mutations should be included in mutation panels.
42 CFR 405.512 - Carriers' procedural terminology and coding systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 2 2013-10-01 2013-10-01 false Carriers' procedural terminology and coding systems... Determining Reasonable Charges § 405.512 Carriers' procedural terminology and coding systems. (a) General. Procedural terminology and coding systems are designed to provide physicians and third party payers with a...
42 CFR 405.512 - Carriers' procedural terminology and coding systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 2 2011-10-01 2011-10-01 false Carriers' procedural terminology and coding systems... Determining Reasonable Charges § 405.512 Carriers' procedural terminology and coding systems. (a) General. Procedural terminology and coding systems are designed to provide physicians and third party payers with a...
42 CFR 405.512 - Carriers' procedural terminology and coding systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 2 2014-10-01 2014-10-01 false Carriers' procedural terminology and coding systems... Determining Reasonable Charges § 405.512 Carriers' procedural terminology and coding systems. (a) General. Procedural terminology and coding systems are designed to provide physicians and third party payers with a...
42 CFR 405.512 - Carriers' procedural terminology and coding systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 2 2012-10-01 2012-10-01 false Carriers' procedural terminology and coding systems... Determining Reasonable Charges § 405.512 Carriers' procedural terminology and coding systems. (a) General. Procedural terminology and coding systems are designed to provide physicians and third party payers with a...
42 CFR 405.512 - Carriers' procedural terminology and coding systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false Carriers' procedural terminology and coding systems... Determining Reasonable Charges § 405.512 Carriers' procedural terminology and coding systems. (a) General. Procedural terminology and coding systems are designed to provide physicians and third party payers with a...
Yokoyama, Masayuki
2010-02-01
A polymeric micelle is a macromolecular assembly composed of an inner core and an outer shell, and most typically is formed from block copolymers. In the last two decades, polymeric micelles have been actively studied as a new type of drug carrier system, in particular for drug targeting of anticancer drugs to solid tumors. In this review, polymeric micelle drug carrier systems are discussed with a focus on toxicities of the polymeric micelle carrier systems and on pharmacological activities of the block copolymers. In the first section, the importance of the above-mentioned evaluation of these properties is explained, as this importance does not seem to be well recognized compared with the importance of targeting and enhanced pharmacological activity of drugs, particularly in the basic studies. Then, designs, types and classifications of the polymeric micelle system are briefly summarized and explained, followed by a detailed discussion regarding several examples of polymeric micelle carrier systems. Readers will gain a strategy of drug delivery with polymeric carriers as well as recent progress of the polymeric micelle carrier systems in their basic studies and clinical trials. The purpose of this review is to achieve tight connections between the basic studies and clinical trials.
49 CFR 1580.201 - Rail security coordinator.
Code of Federal Regulations, 2010 CFR
2010-10-01
... system that is not operating on track that is part of the general railroad system of transportation... SECURITY Passenger Rail Including Passenger Railroad Carriers, Rail Transit Systems, Tourist, Scenic.... This section applies to: (1) Each passenger railroad carrier, including each carrier operating light...
Magnetic field induced enhancement of resistance in polycrystalline ZrTe5
NASA Astrophysics Data System (ADS)
Behera, Prakash; Bera, Sumit; Patidar, Manju Mishra; Singh, Durgesh; Mishra, A. K.; Krishnan, M.; Gangrade, M.; Deshpande, U. P.; Venkatesh, R.; Ganesan, V.
2018-04-01
Transport properties of the polycrystalline ZrTe5 showing a considerable positive Magneto-Resistance (MR) in the intermediate temperatures has been reported. Substantial shift of peak temperature by approximately 65 K with an applied magnetic field of 13.5 Tesla has been observed. Magneto resistance of this polycrystalline sample (˜100%) is comparable with its single crystalline counterpart reported in literature. The peak intensity scales with peak temperature and obeys reasonably the Dionne relationship that is a clear indication of polaron mediated conduction in this system. Magneto Resistance (MR) in this system is attributed to the two carrier polaronic conduction model similar to the Holstein's approach. The results are further complemented with the Peak shift in magnetic field expected for a system having a fraction of localized carrier density. This observation places this famous thermoelectric material that displays a topological Dirac to Weyl transition in magnetic field in to the family of materials that have potential technological applications in the liquid nitrogen temperature range viz. 85-150 K.
Chemical vapor deposition growth
NASA Technical Reports Server (NTRS)
Ruth, R. P.; Manasevit, H. M.; Kenty, J. L.; Moudy, L. A.; Simpson, W. I.; Yang, J. J.
1976-01-01
A chemical vapor deposition (CVD) reactor system with a vertical deposition chamber was used for the growth of Si films on glass, glass-ceramic, and polycrystalline ceramic substrates. Silicon vapor was produced by pyrolysis of SiH4 in a H2 or He carrier gas. Preliminary deposition experiments with two of the available glasses were not encouraging. Moderately encouraging results, however, were obtained with fired polycrystalline alumina substrates, which were used for Si deposition at temperatures above 1,000 C. The surfaces of both the substrates and the films were characterized by X-ray diffraction, reflection electron diffraction, scanning electron microscopy optical microscopy, and surface profilometric techniques. Several experiments were conducted to establish baseline performance data for the reactor system, including temperature distributions on the sample pedestal, effects of carrier gas flow rate on temperature and film thickness, and Si film growth rate as a function of temperature.
47 CFR 15.113 - Power line carrier systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... subject only to the following requirements: (a) A power utility operating a power line carrier system... systems to an industry-operated entity as set forth in § 90.63(g) of this chapter. No notification to the FCC is required. (b) The operating parameters of a power line carrier system (particularly the...
Zhou, Zhengzhen; Guo, Laodong
2015-06-19
Colloidal retention characteristics, recovery and size distribution of model macromolecules and natural dissolved organic matter (DOM) were systematically examined using an asymmetrical flow field-flow fractionation (AFlFFF) system under various membrane size cutoffs and carrier solutions. Polystyrene sulfonate (PSS) standards with known molecular weights (MW) were used to determine their permeation and recovery rates by membranes with different nominal MW cutoffs (NMWCO) within the AFlFFF system. Based on a ≥90% recovery rate for PSS standards by the AFlFFF system, the actual NMWCOs were determined to be 1.9 kDa for the 0.3 kDa membrane, 2.7 kDa for the 1 kDa membrane, and 33 kDa for the 10 kDa membrane, respectively. After membrane calibration, natural DOM samples were analyzed with the AFlFFF system to determine their colloidal size distribution and the influence from membrane NMWCOs and carrier solutions. Size partitioning of DOM samples showed a predominant colloidal size fraction in the <5 nm or <10 kDa size range, consistent with the size characteristics of humic substances as the main terrestrial DOM component. Recovery of DOM by the AFlFFF system, as determined by UV-absorbance at 254 nm, decreased significantly with increasing membrane NMWCO, from 45% by the 0.3 kDa membrane to 2-3% by the 10 kDa membrane. Since natural DOM is mostly composed of lower MW substances (<10 kDa) and the actual membrane cutoffs are normally larger than their manufacturer ratings, a 0.3 kDa membrane (with an actual NMWCO of 1.9 kDa) is highly recommended for colloidal size characterization of natural DOM. Among the three carrier solutions, borate buffer seemed to provide the highest recovery and optimal separation of DOM. Rigorous calibration with macromolecular standards and optimization of system conditions are a prerequisite for quantifying colloidal size distribution using the flow field-flow fractionation technique. In addition, the coupling of AFlFFF with fluorescence EEMs could provide new insights into DOM heterogeneity in different colloidal size fractions. Copyright © 2015 Elsevier B.V. All rights reserved.
Geraets, D T; van Baars, R; Alonso, I; Ordi, J; Torné, A; Melchers, W J G; Meijer, C J L M; Quint, W G V
2013-06-01
High-risk human papillomavirus (hrHPV) testing in cervical screening is usually performed on physician-taken cervical smears in liquid-based medium. However, solid-state specimen carriers allow easy, non-hazardous storage and transportation and might be suitable for self-collection by non-responders in screening and in low-resource settings. We evaluated the adequacy of self-collected cervicovaginal (c/v) samples using a Viba-brush stored on an Indicating FTA-elute cartridge (FTA-based self-sampling) for hrHPV testing in women referred to a gynecology clinic due to an abnormal smear. 182 women accepted to self-collect a c/v sample. After self-sampling, a physician obtained a conventional liquid-based cervical smear. Finally, women were examined by colposcopy and a biopsy was taken when clinically indicated. Self-samples required only simple DNA elution, and DNA was extracted from physician-obtained samples. Both samples were tested for 14 hrHPVs by GP5+/6+-EIA-LQ Test and SPF(10)-DEIA-LiPA(25). Both assays detected significantly more hrHPV in physician-collected specimens than in self-collected samples (75.3% and 67.6% by SPF(10); 63.3% and 53.3% by GP5+/6+, respectively). The combination of physician-collected specimen and GP5+/6+ testing demonstrated the optimal balance in sensitivity (98.0%) and specificity (48.1%) for CIN2+ detection in this referral population. A test system of FTA-based self-collection and SPF(10) hrHPV detection approached this sensitivity (95.9%) and specificity (42.9%). These results show that the clinical performance of hrHPV detection is determined by both the sample collection system and the test method. FTA-based self-collection with SPF(10) testing might be valuable when a liquid-based medium cannot be used, but requires further investigation in screening populations. Copyright © 2013 Elsevier B.V. All rights reserved.
Method and system for providing precise multi-function modulation
NASA Technical Reports Server (NTRS)
Davarian, Faramaz (Inventor); Sumida, Joe T. (Inventor)
1989-01-01
A method and system is disclosed which provides precise multi-function digitally implementable modulation for a communication system. The invention provides a modulation signal for a communication system in response to an input signal from a data source. A digitized time response is generated from samples of a time domain representation of a spectrum profile of a selected modulation scheme. The invention generates and stores coefficients for each input symbol in accordance with the selected modulation scheme. The output signal is provided by a plurality of samples, each sample being generated by summing the products of a predetermined number of the coefficients and a predetermined number of the samples of the digitized time response. In a specific illustrative implementation, the samples of the output signals are converted to analog signals, filtered and used to modulate a carrier in a conventional manner. The invention is versatile in that it allows for the storage of the digitized time responses and corresponding coefficient lookup table of a number of modulation schemes, any of which may then be selected for use in accordance with the teachings of the invention.
NASA Technical Reports Server (NTRS)
Augustynowicz, Stanislaw D. (Inventor); Fesmire, James E. (Inventor)
2005-01-01
Thermal insulation systems and with methods of their production. The thermal insulation systems incorporate at least one reflection layer and at least one spacer layer in an alternating pattern. Each spacer layer includes a fill layer and a carrier layer. The fill layer may be separate from the carrier layer, or it may be a part of the carrier layer, i.e., mechanically injected into the carrier layer or chemically formed in the carrier layer. Fill layers contain a powder having a high surface area and low bulk density. Movement of powder within a fill layer is restricted by electrostatic effects with the reflection layer combined with the presence of a carrier layer, or by containing the powder in the carrier layer. The powder in the spacer layer may be compressed from its bulk density. The thermal insulation systems may further contain an outer casing. Thermal insulation systems may further include strips and seams to form a matrix of sections. Such sections serve to limit loss of powder from a fill layer to a single section and reduce heat losses along the reflection layer.
Useful Life Prediction for Payload Carrier Hardware
NASA Technical Reports Server (NTRS)
Ben-Arieh, David
2002-01-01
The Space Shuttle has been identified for use through 2020. Payload carrier systems will be needed to support missions through the same time frame. To support the future decision making process with reliable systems, it is necessary to analyze design integrity, identify possible sources of undesirable risk and recognize required upgrades for carrier systems. This project analyzed the information available regarding the carriers and developed the probability of becoming obsolete under different scenarios. In addition, this project resulted in a plan for an improved information system that will improve monitoring and control of the various carriers. The information collected throughout this project is presented in this report as process flow, historical records, and statistical analysis.
Viger, Mathieu L; Sheng, Wangzhong; McFearin, Cathryn L; Berezin, Mikhail Y; Almutairi, Adah
2013-11-10
Though accurately evaluating the kinetics of release is critical for validating newly designed therapeutic carriers for in vivo applications, few methods yet exist for release measurement in real time and without the need for any sample preparation. Many of the current approaches (e.g. chromatographic methods, absorption spectroscopy, or NMR spectroscopy) rely on isolation of the released material from the loaded vehicles, which require additional sample purification and can lead to loss of accuracy when probing fast kinetics of release. In this study we describe the use of time-resolved fluorescence for in situ monitoring of small molecule release kinetics from biodegradable polymeric drug delivery systems. This method relies on the observation that fluorescent reporters being released from polymeric drug delivery systems possess distinct excited-state lifetime components, reflecting their different environments in the particle suspensions, i.e., confined in the polymer matrices or free in the aqueous environment. These distinct lifetimes enable real-time quantitative mapping of the relative concentrations of dye in each population to obtain precise and accurate temporal information on the release profile of particular carrier/payload combinations. We found that fluorescence lifetime better distinguishes subtle differences in release profiles (e.g. differences associated with dye loading) than conventional steady-state fluorescence measurements, which represent the averaged dye behavior over the entire scan. Given the method's applicability to both hydrophobic and hydrophilic cargo, it could be employed to model the release of any drug-carrier combination. Copyright © 2013 Elsevier B.V. All rights reserved.
14 CFR Sec. 19-7 - Passenger origin-destination survey.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Transportation Statistics' Director of Airline Information. (c) A statistically valid sample of light coupons... LAX Salt Lake City NorthwestOperating Carrier NorthwestTicketed Carrier Fare Code Phoenix American...
DOT National Transportation Integrated Search
2017-09-01
MnDOT uses two online systems implemented in the 1990s to issue and manage permits for oversize/overweight (OS/OW) freight and motor carrier credentials: - RouteBuilder, an OS/OW permitting system with a routing component. - Motor Carrier Information...
14 CFR 255.5 - Contracts with participating carriers.
Code of Federal Regulations, 2011 CFR
2011-01-01
... (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS AIRLINE COMPUTER RESERVATIONS SYSTEMS § 255.5 Contracts with participating carriers. (a) No system may require a carrier to maintain any particular level of participation or buy any enhancements in its system on the basis of participation levels or enhancements selected by...
14 CFR 255.5 - Contracts with participating carriers.
Code of Federal Regulations, 2010 CFR
2010-01-01
... (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS AIRLINE COMPUTER RESERVATIONS SYSTEMS § 255.5 Contracts with participating carriers. (a) No system may require a carrier to maintain any particular level of participation or buy any enhancements in its system on the basis of participation levels or enhancements selected by...
ADRA2B Deletion Variant Influences Time-Dependent Effects of Pre-Learning Stress on Long-Term Memory
Zoladz, Phillip R.; Dailey, Alison M.; Nagle, Hannah E.; Fiely, Miranda K.; Mosley, Brianne E.; Brown, Callie M.; Duffy, Tessa J.; Scharf, Amanda R.; Earley, McKenna B.; Rorabaugh, Boyd R.
2017-01-01
Extensive work over the past few decades has shown that certain genetic variations interact with life events to confer increased susceptibility for the development of psychological disorders. The deletion variant of the ADRA2B gene, which has been associated with enhanced emotional memory and heightened amygdala responses to emotional stimuli, might confer increased susceptibility for the development of post-traumatic stress disorder (PTSD) or related phenotypes by increasing the likelihood of traumatic memory formation. Thus, we examined whether this genetic variant would predict stress effects on learning and memory in a non-clinical sample. Two hundred and thirty-five individuals were exposed to the socially evaluated cold pressor test or a control condition immediately or 30 min prior to learning a list of words that varied in emotional valence and arousal level. Participants’ memory for the words was tested immediately (recall) and 24 h after learning (recall and recognition), and saliva samples were collected to genotype participants for the ADRA2B deletion variant. Results showed that stress administered immediately before learning selectively enhanced long-term recall in deletion carriers. Stress administered 30 min before learning impaired recognition memory in male deletion carriers, while enhancing recognition memory in female deletion carriers. These findings provide additional evidence to support the idea that ADRA2B deletion variant carriers retain a sensitized stress response system, which results in amplified effects of stress on learning and memory. The accumulating evidence regarding this genetic variant implicates it as a susceptibility factor for traumatic memory formation and PTSD-related phenotypes. PMID:28254464
Barton, H.N.
1986-01-01
Trace levels of chalcophile elements that form volatile sulfide minerals are determined in stream sediments and in the nonmagnetic fraction of a heavy-mineral concentrate of stream sediments by a carrier distillation emission spectrographic method. Photographically recorded spectra of samples are visually compared with those of synthetic standards for the two sample types. Rock and soil samples may also be analyzed by comparison with the stream-sediment standards. A gallium oxide spectrochemical carrier/buffer enhances the early emission of the volatile elements. Detection limits in parts per million attained are: Sb 5, As 20, Bi 0.1, Cd 1, Cu 1, Pb 2, Ag 0.1, Zn 2, and Sn 0.1. A comparison with other methods of analysis, total-burn emission and atomic absorption spectroscopy, shows good correlation for standard reference for materials and samples from a variety of geologic terranes. ?? 1986.
A frontal dopamine system for reflective exploratory behavior.
Blanco, Nathaniel J; Love, Bradley C; Cooper, Jessica A; McGeary, John E; Knopik, Valerie S; Maddox, W Todd
2015-09-01
The COMT gene modulates dopamine levels in prefrontal cortex with Met allele carriers having lower COMT enzyme activity and, therefore, higher dopamine levels compared to Val/Val homozygotes. Concordantly, Val/Val homozygotes tend to perform worse and display increased (interpreted as inefficient) frontal activation in certain cognitive tasks. In a sample of 209 participants, we test the hypothesis that Met carriers will be advantaged in a decision-making task that demands sequencing exploratory and exploitive choices to minimize uncertainty about the reward structure in the environment. Previous work suggests that optimal performance depends on limited cognitive resources supported by prefrontal systems. If so, Met carriers should outperform Val/Val homozygotes, particularly under dual-task conditions that tax limited cognitive resources. In accord with these a priori predictions, Met carriers were more resilient in the face of cognitive load, continuing to explore in a sophisticated manner. We fit computational models that embody sophisticated reflective and simple reflexive strategies to further evaluate participants' exploration behavior. The Ideal Actor model reflectively updates beliefs and plans ahead, taking into account the information gained by each choice and making choices that maximize long-term payoffs. In contrast, the Naïve Reinforcement Learning (RL) model instantiates the reflexive account of choice, in which the values of actions are based only on the rewards experienced so far. Its beliefs are updated reflexively in response to observed changes in rewards. Converging with standard analyses, Met carriers were best characterized by the Ideal Actor model, whereas Val/Val homozygotes were best characterized by the Naive RL model, particularly under dual-task conditions. Copyright © 2015 Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Sample distribution by means other than mail or common carrier (direct delivery by a representative or detailer). 203.31 Section 203.31 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL...
Charge Energy Transport in Hopping Systems with Rapidly Decreasing Density of States
NASA Astrophysics Data System (ADS)
Mendels, Dan; Organic Electronics Group Technion Team
2014-03-01
An accurate description of the carrier hopping topology in the energy domain of hopping systems incorporating a rapidly decreasing density of states and the subsequent energetic position of these systems' so called effective conduction band is crucial for rationalizing and quantifying these systems' thermo-electric properties, doping related phenomena and carrier gradient effects such as the emergence of the General Einstein Relation under degenerate conditions. Additionally, as will be shown, the 'mobile' carriers propagating through the system can have excess energies reaching 0.3eV above the system quasi-Fermi energy. Hence, since these mobile carriers are most prone to reach systems interfaces and interact with oppositely charged carriers, their excess energy should be considered in determining the efficiencies of energy dependent processes such as carrier recombination and exciton dissociation. In light of the stated motivations, a comprehensive numerical and analytical study of the topology of hopping in the energetic density of such systems (i.e. the statistics regarding which energy values carriers visit most and in what manner) was implemented and the main statistical features of the hopping process that determine the position in energy of the system's effective conduction band were distilled. The obtained results also help shed light on yet to be elucidated discrepancies between predictions given by the widely employed transport energy concept and Monte Carlo simulations.
USDA-ARS?s Scientific Manuscript database
Several FMDV carrier cattle were identified in Vietnam by recovery of infectious virus from oropharyngeal fluid. This report contains the first near-complete genome sequences of seven viruses isolated from a single carrier animal over the course of one year. Understanding within-host viral evolution...
Modifying the Casimir force between indium tin oxide film and Au sphere
NASA Astrophysics Data System (ADS)
Banishev, A. A.; Chang, C.-C.; Castillo-Garza, R.; Klimchitskaya, G. L.; Mostepanenko, V. M.; Mohideen, U.
2012-01-01
We present complete results of the experiment on measuring the Casimir force between an Au-coated sphere and an untreated or, alternatively, UV-treated indium tin oxide (ITO) film deposited on a quartz substrate. Measurements were performed using an atomic force microscope in a high vacuum chamber. The measurement system was calibrated electrostatically. Special analysis of the systematic deviations is performed, and respective corrections in the calibration parameters are introduced. The corrected parameters are free from anomalies discussed in the literature. The experimental data for the Casimir force from two measurement sets for both untreated and UV-treated samples are presented. The random, systematic, and total experimental errors are determined at a 95% confidence level. It is demonstrated that the UV treatment of an ITO plate results in a significant decrease in the magnitude of the Casimir force (from 21% to 35% depending on separation). However, ellipsometry measurements of the imaginary parts of dielectric permittivities of the untreated and UV-treated samples did not reveal any significant differences. The experimental data are compared with computations in the framework of the Lifshitz theory. It is found that the data for the untreated sample are in a very good agreement with theoretical results taking into account the free charge carriers in an ITO film. For the UV-treated sample the data exclude the theoretical results obtained with account of free charge carriers. These data are in very good agreement with computations disregarding the contribution of free carriers in the dielectric permittivity. According to the hypothetical explanation provided, this is caused by the phase transition of the ITO film from metallic to dielectric state caused by the UV treatment. Possible applications of the discovered phenomenon in nanotechnology are discussed.
Nonuniform carrier density in Cd 3 As 2 evidenced by optical spectroscopy
Crassee, I.; Martino, E.; Homes, C. C.; ...
2018-03-22
In this paper, we report the detailed optical properties of Cd 3As 2 crystals in a wide parameter space: temperature, magnetic field, carrier concentration, and crystal orientation. We investigate high-quality crystals synthesized by three different techniques. In all the studied samples, independently of how they were prepared and how they were treated before the optical experiments, our data indicate conspicuous fluctuations in the carrier density (up to 30%). These charge puddles have a characteristic scale of 100 μm, they become more pronounced at low temperatures, and possibly, they become enhanced by the presence of crystal twinning. The Drude response ismore » characterized by very small scattering rates (~1 meV) for as-grown samples. Mechanical treatment, such as cutting or polishing, influences the optical properties of single crystals, by increasing the Drude scattering rate and also modifying the high-frequency optical response. Finally, magnetoreflectivity and Kerr rotation are consistent with electronlike charge carriers and a spatially nonuniform carrier density.« less
Nonuniform carrier density in Cd3As2 evidenced by optical spectroscopy
NASA Astrophysics Data System (ADS)
Crassee, I.; Martino, E.; Homes, C. C.; Caha, O.; Novák, J.; Tückmantel, P.; Hakl, M.; Nateprov, A.; Arushanov, E.; Gibson, Q. D.; Cava, R. J.; Koohpayeh, S. M.; Arpino, K. E.; McQueen, T. M.; Orlita, M.; Akrap, Ana
2018-03-01
We report the detailed optical properties of Cd3As2 crystals in a wide parameter space: temperature, magnetic field, carrier concentration, and crystal orientation. We investigate high-quality crystals synthesized by three different techniques. In all the studied samples, independently of how they were prepared and how they were treated before the optical experiments, our data indicate conspicuous fluctuations in the carrier density (up to 30%). These charge puddles have a characteristic scale of 100 μ m , they become more pronounced at low temperatures, and possibly, they become enhanced by the presence of crystal twinning. The Drude response is characterized by very small scattering rates (˜1 meV) for as-grown samples. Mechanical treatment, such as cutting or polishing, influences the optical properties of single crystals, by increasing the Drude scattering rate and also modifying the high-frequency optical response. Magnetoreflectivity and Kerr rotation are consistent with electronlike charge carriers and a spatially nonuniform carrier density.
Nonuniform carrier density in Cd 3 As 2 evidenced by optical spectroscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crassee, I.; Martino, E.; Homes, C. C.
In this paper, we report the detailed optical properties of Cd 3As 2 crystals in a wide parameter space: temperature, magnetic field, carrier concentration, and crystal orientation. We investigate high-quality crystals synthesized by three different techniques. In all the studied samples, independently of how they were prepared and how they were treated before the optical experiments, our data indicate conspicuous fluctuations in the carrier density (up to 30%). These charge puddles have a characteristic scale of 100 μm, they become more pronounced at low temperatures, and possibly, they become enhanced by the presence of crystal twinning. The Drude response ismore » characterized by very small scattering rates (~1 meV) for as-grown samples. Mechanical treatment, such as cutting or polishing, influences the optical properties of single crystals, by increasing the Drude scattering rate and also modifying the high-frequency optical response. Finally, magnetoreflectivity and Kerr rotation are consistent with electronlike charge carriers and a spatially nonuniform carrier density.« less
Benefits of Nuclear Electric Propulsion for Outer Planet Exploration
NASA Technical Reports Server (NTRS)
Kos, Larry; Johnson, Les; Jones, Jonathan; Trausch, Ann; Eberle, Bill; Woodcock, Gordon; Brady, Hugh J. (Technical Monitor)
2002-01-01
Nuclear electric propulsion (NEP) offers significant benefits to missions for outer planet exploration. Reaching outer planet destinations, especially beyond Jupiter, is a struggle against time and distance. For relatively near missions, such as a Europa lander, conventional chemical propulsion and NEP offer similar performance and capabilities. For challenging missions such as a Pluto orbiter, neither chemical nor solar electric propulsion are capable while NEP offers acceptable performance. Three missions are compared in this paper: Europa lander, Pluto orbiter, and Titan sample return, illustrating how performance of conventional and advanced propulsion systems vary with increasing difficulty. The paper presents parametric trajectory performance data for NEP. Preliminary mass/performance estimates are provided for a Europa lander and a Titan sample return system, to derive net payloads for NEP. The NEP system delivers payloads and ascent/descent spacecraft to orbit around the target body, and for sample return, delivers the sample carrier system from Titan orbit to an Earth transfer trajectory. A representative scientific payload 500 kg was assumed, typical for a robotic mission. The resulting NEP systems are 100-kWe class, with specific impulse from 6000 to 9000 seconds.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-30
... and Implementing an Air Carrier Continuing Analysis and Surveillance System AGENCY: Federal Aviation... Analysis and Surveillance System''. This new advisory circular (AC) updates AC 120-79 originally issued on... Analysis and Surveillance System (CASS) required for commercial operators and air carriers certificated...
47 CFR 15.107 - Conducted limits.
Code of Federal Regulations, 2010 CFR
2010-10-01
... not apply to carrier current systems operating as unintentional radiators on frequencies below 30 MHz... carrier current systems containing their fundamental emission within the frequency band 535-1705 kHz and... 50 μH/50 ohms LISN. (3) Carrier current systems operating below 30 MHz are also subject to the...
Oota, Shinichi; Hatae, Yuta; Amada, Kei; Koya, Hidekazu; Kawakami, Mitsuyasu
2010-09-15
Although microbial biochemical oxygen demand (BOD) sensors utilizing redox mediators have attracted much attention as a rapid BOD measurement method, little attempts have been made to apply the mediated BOD biosensors to the flow injection analysis system. In this work, a mediated BOD sensor system of flow injection mode, constructed by combining an immobilized microbial reactor with an electrochemical flow cell of three electrodes configuration, has been developed to estimate BOD of shochu distillery wastewater (SDW). It was demonstrated consequently that the mediated sensing was realized by employing phosphate buffer containing potassium hexacyanoferrate as the carrier. The output current was found to yield a peak with a sample injection, and to result from reoxidation of reduced mediator at the electrode. By employing the peak area as the sensor response, the effects of flow rate and pH of the carrier on the sensitivity were investigated. The sensor system using a microorganism of high SDW-assimilation capacity showed good performance and proved to be available for estimation of BOD of SDW. Copyright 2010 Elsevier B.V. All rights reserved.
14 CFR Section 04 - Air Carrier Groupings
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false Air Carrier Groupings Section 04 Section 04... REGULATIONS UNIFORM SYSTEM OF ACCOUNTS AND REPORTS FOR LARGE CERTIFICATED AIR CARRIERS Section 04 Air Carrier Groupings (a) All large certificated air carriers are placed into three basic air carrier groupings based...
14 CFR Section 04 - Air Carrier Groupings
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Air Carrier Groupings Section 04 Section 04... REGULATIONS UNIFORM SYSTEM OF ACCOUNTS AND REPORTS FOR LARGE CERTIFICATED AIR CARRIERS Section 04 Air Carrier Groupings (a) All large certificated air carriers are placed into three basic air carrier groupings based...
14 CFR Section 04 - Air Carrier Groupings
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Air Carrier Groupings Section 04 Section 04... REGULATIONS UNIFORM SYSTEM OF ACCOUNTS AND REPORTS FOR LARGE CERTIFICATED AIR CARRIERS Section 04 Air Carrier Groupings (a) All large certificated air carriers are placed into three basic air carrier groupings based...
14 CFR Section 04 - Air Carrier Groupings
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false Air Carrier Groupings Section 04 Section 04... REGULATIONS UNIFORM SYSTEM OF ACCOUNTS AND REPORTS FOR LARGE CERTIFICATED AIR CARRIERS Section 04 Air Carrier Groupings (a) All large certificated air carriers are placed into three basic air carrier groupings based...
Novel diluted magnetic semiconductor materials based on zinc oxide
NASA Astrophysics Data System (ADS)
Chakraborti, Deepayan
The primary aim of this work was to develop a ZnO based diluted magnetic semiconductor (DMS) materials system which displays ferromagnetism above room temperature and to understand the origin of long-range ferromagnetic ordering in these systems. Recent developments in the field of spintronics (spin based electronics) have led to an extensive search for materials in which semiconducting properties can be integrated with magnetic properties to realize the objective of successful fabrication of spin-based devices. For these devices we require a high efficiency of spin current injection at room temperature. Diluted magnetic semiconductors (DMS) can serve this role, but they should not only display room temperature ferromagnetism (RTFM) but also be capable of generating spin polarized carriers. Transition metal doped ZnO has proved to be a potential candidate as a DMS showing RTFM. The origin of ferromagnetic ordering in ZnO is still under debate. However, the presence of magnetic secondary phases, composition fluctuations and nanoclusters could also explain the observation of ferromagnetism in the DMS samples. This encouraged us to investigate Cu-doped(+ spin in the 2+ valence state) ZnO system as a probable candidate exhibiting RTFM because neither metallic Cu nor its oxides (Cu2O or CuO) are ferromagnetic. The role of defects and free carriers on the ferromagnetic ordering of Cu-doped ZnO thin films was studied to ascertain the origin of ferromagnetism in this system. A novel non-equilibrium Pulsed Laser Deposition technique has been used to grow high quality epitaxial thin films of Cu:ZnO and (Co,Cu):ZnO on c-plane Sapphire by domain matching epitxay. Both the systems showed ferromagnetic ordering above 300K but Cu ions showed a much stronger ferromagnetic ordering than Co, especially at low concentrations (1-2%) of Cu where we realized near 100% polarization. But, the incorporation of Cu resulted in a 2-order of magnitude rise in the resistivity from 10-1 to 101 Ohm cm which can prove to be detrimental to the injection of polarized electrons. In order to decrease the resistivity and to understand the role of free carriers in mediating the ferromagnetic ordering, the Cu-doped ZnO films were co-doped with an n-type dopant like Al which increased the free carriers concentration by 3 orders of magnitude from 1017 to 1020 cm -3 without significantly altering the near 100% spin polarization in the Cu:ZnO system. This lack of correlation between free carrier concentration and the magnetic moment implied that a free carrier mediated exchange does not stabilize the long range ferromagnetic ordering. A reduction in the number of oxygen vacancies brought about by high temperature oxygen annealing had a large degrading effect on the ferromagnetism by reducing the total saturation magnetization by almost an order of magnitude. This strong dependence of magnetization on vacancy concentration and the corresponding weak relationship with free carriers pointed towards a defect mediated mechanism, such as a bound magnetic polaron mediated exchange as being responsible for stabilizing the ferromagnetic ordering in these systems. However, a BMP mechanism would not guarantee a strong coupling between the free carriers and the localized spins to produce spin-polarized current. To investigate this we have fabricated spin valve type device structures where a nonmagnetic ZnO layer was sandwiched between two ferromagnetic (Cu,Al):ZnO layers allowing us to study spin polarized carrier injection across the nonmagnetic semiconductor gap. Initial results have shown evidence of spin polarized carrier injection across the nonmagnetic semiconductor layer even at 300K. Hence, this work demonstrates that the (Cu,Al):ZnO system may become a viable solution for spin injection into spintronic devices.
Varchi, Greta; Benfenati, Valentina; Pistone, Assunta; Ballestri, Marco; Sotgiu, Giovanna; Guerrini, Andrea; Dambruoso, Paolo; Liscio, Andrea; Ventura, Barbara
2013-05-01
Among the medical applications of nanoparticles, their usage as photosensitizer (PS) carriers for photodynamic therapy (PDT) has attracted increasing attention. In the present study we explored the morphological and photophysical properties of core-shell PMMA nanoparticles (PMMA-NPs) electrostatically post-loaded with the synthetic, water soluble 5,10,15,20-tetrakis(4-sulphonatophenyl)-porphyrin (TPPS4). pH response and singlet oxygen analyses of differently loaded samples proved the high capability of the PMMA-NPs to shield the PS from the environment, while retaining the PS singlet oxygen production capability. Preliminary in vitro imaging and phototoxicity experiments on HepG2 cells demonstrated the efficacy of the system to trigger photoinduced cell death in the culture.
Study of conduction behavior in Pr0.67Sr0.03Ag0.30MnO3
NASA Astrophysics Data System (ADS)
Bhat, Masroor Ahmad; Modi, Anchit; Pandey, Devendra K.; Gaur, N. K.
2018-05-01
In this paper, we report the conduction mechanism in Pr0.67Sr0.03Ag0.30MnO3 system synthesized via conventional solid state reaction route. The structural information was carried by X - Ray diffraction using Rietveld refinement which confirms the secondary phase of the sample. The SEM image shows the formation of double phase composite because of limited reaction of silver with parent compound. The resistivity behavior indicates the semiconducting behavior. The electronic nature can be estimated by means of variable range hopping (VRH) and small polaron hopping (SPH) model showing that the enhancement of double exchange interaction suppress the band gap and boost the carrier delocalization of charge carriers.
Digital Baseband Architecture For Transponder
NASA Technical Reports Server (NTRS)
Nguyen, Tien M.; Yeh, Hen-Geul
1995-01-01
Proposed advanced transponder for long-distance radio communication system with turnaround ranging contains carrier-signal-tracking loop including baseband digital "front end." For reduced cost, transponder includes analog intermediate-frequency (IF) section and analog automatic gain control (AGC) loop at first of two IF mixers. However, second IF mixer redesigned to ease digitization of baseband functions. To conserve power and provide for simpler and smaller transponder hardware, baseband digital signal-processing circuits designed to implement undersampling scheme. Furthermore, sampling scheme and sampling frequency chosen so redesign involves minimum modification of command-detector unit (CDU).
Air carrier operations system model
DOT National Transportation Integrated Search
2001-03-01
Representatives from the Federal Aviation Administration (FAA) and several 14 Code of Federal Regulations (CFR) Part 121 air carriers met several times during 1999-2000 to develop a system engineering model of the generic functions of air carrier ope...
An open circuit voltage decay system for performing injection dependent lifetime spectroscopy
NASA Astrophysics Data System (ADS)
Lacouture, Shelby; Schrock, James; Hirsch, Emily; Bayne, Stephen; O'Brien, Heather; Ogunniyi, Aderinto A.
2017-09-01
Of all of the material parameters associated with a semiconductor, the carrier lifetime is by far the most complex and dynamic, being a function of the dominant recombination mechanism, the equilibrium number of carriers, the perturbations in carriers (e.g., carrier injection), and the temperature, to name the most prominent variables. The carrier lifetime is one of the most important parameters in bipolar devices, greatly affecting conductivity modulation, on-state voltage, and reverse recovery. Carrier lifetime is also a useful metric for device fabrication process control and material quality. As it is such a dynamic quantity, carrier lifetime cannot be quoted in a general range such as mobility; it must be measured. The following describes a stand-alone, wide-injection range open circuit voltage decay system with unique lifetime extraction algorithms. The system is initially used along with various lifetime spectroscopy techniques to extract fundamental recombination parameters from a commercial high-voltage PIN diode.
Mateu-Huertas, Elisabet; Rodriguez-Revenga, Laia; Alvarez-Mora, Maria Isabel; Madrigal, Irene; Willemsen, Rob; Milà, Montserrat; Martí, Eulàlia; Estivill, Xavier
2014-05-01
Male premutation carriers presenting between 55 and 200 CGG repeats in the Fragile-X-associated (FMR1) gene are at risk of developing Fragile X Tremor/Ataxia Syndrome (FXTAS), and females undergo Premature Ovarian Failure (POF1). Here, we have evaluated gene expression profiles from blood in male FMR1 premutation carriers and detected a strong deregulation of genes enriched in FXTAS relevant biological pathways, including inflammation, neuronal homeostasis and viability. Gene expression profiling distinguished between control individuals, carriers with FXTAS and carriers without FXTAS, with levels of expanded FMR1 mRNA being increased in FXTAS patients. In vitro studies in a neuronal cell model indicate that expression levels of expanded FMR1 5'-UTR are relevant in modulating the transcriptome. Thus, perturbations of the transcriptome may be an interplay between the CGG expansion size and FMR1 expression levels. Several deregulated genes (DFFA, BCL2L11, BCL2L1, APP, SOD1, RNF10, HDAC5, KCNC3, ATXN7, ATXN3 and EAP1) were validated in brain samples of a FXTAS mouse model. Downregulation of EAP1, a gene involved in the female reproductive system physiology, was confirmed in female carriers. Decreased levels were detected in female carriers with POF1 compared to those without POF1, suggesting that EAP1 levels contribute to ovarian insufficiency. In summary, gene expression profiling in blood has uncovered mechanisms that may underlie different pathological aspects of the premutation. A better understanding of the transcriptome dynamics in relation with expanded FMR1 mRNA expression levels and CGG expansion size may provide mechanistic insights into the disease process and a more accurate FXTAS diagnosis to the myriad of phenotypes associated with the premutation. Copyright © 2014. Published by Elsevier Inc.
Jinno, Naoya; Hashimoto, Masahiko; Tsukagoshi, Kazuhiko
2011-01-01
A capillary chromatography system has been developed based on the tube radial distribution of the carrier solvents using an open capillary tube and a water-acetonitrile-ethyl acetate mixture carrier solution. This tube radial distribution chromatography (TRDC) system works under laminar flow conditions. In this study, a phase diagram for the ternary mixture carrier solvents of water, acetonitrile, and ethyl acetate was constructed. The phase diagram that included a boundary curve between homogeneous and heterogeneous solutions was considered together with the component ratios of the solvents in the homogeneous carrier solutions required for the TRDC system. It was found that the TRDC system performed well with homogeneous solutions having component ratios of the solvents that were positioned near the homogeneous-heterogeneous solution boundary of the phase diagram. For preparing the carrier solutions of water-hydrophilic/hydrophobic organic solvents for the TRDC system, we used for the first time methanol, ethanol, 1,4-dioxane, and 1-propanol, instead of acetonitrile (hydrophilic organic solvent), as well as chloroform and 1-butanol, instead of ethyl acetate (hydrophobic organic solvent). The homogeneous ternary mixture carrier solutions were prepared near the homogeneous-heterogeneous solution boundary. Analyte mixtures of 2,6-naphthalenedisulfonic acid and 1-naphthol were separated with the TRDC system using these homogeneous ternary mixture carrier solutions. The pressure change in the capillary tube under laminar flow conditions might alter the carrier solution from homogeneous in the batch vessel to heterogeneous, thus affecting the tube radial distribution of the solvents in the capillary tube.
CFO compensation method using optical feedback path for coherent optical OFDM system
NASA Astrophysics Data System (ADS)
Moon, Sang-Rok; Hwang, In-Ki; Kang, Hun-Sik; Chang, Sun Hyok; Lee, Seung-Woo; Lee, Joon Ki
2017-07-01
We investigate feasibility of carrier frequency offset (CFO) compensation method using optical feedback path for coherent optical orthogonal frequency division multiplexing (CO-OFDM) system. Recently proposed CFO compensation algorithms provide wide CFO estimation range in electrical domain. However, their practical compensation range is limited by sampling rate of an analog-to-digital converter (ADC). This limitation has not drawn attention, since the ADC sampling rate was high enough comparing to the data bandwidth and CFO in the wireless OFDM system. For CO-OFDM, the limitation is becoming visible because of increased data bandwidth, laser instability (i.e. large CFO) and insufficient ADC sampling rate owing to high cost. To solve the problem and extend practical CFO compensation range, we propose a CFO compensation method having optical feedback path. By adding simple wavelength control for local oscillator, the practical CFO compensation range can be extended to the sampling frequency range. The feasibility of the proposed method is experimentally investigated.
47 CFR 15.113 - Power line carrier systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
...-interference basis in accordance with § 15.5 of this part. If harmful interference occurs, the electric power... frequencies. (e) Power line carrier system apparatus shall conform to such engineering standards as may be... 47 Telecommunication 1 2012-10-01 2012-10-01 false Power line carrier systems. 15.113 Section 15...
Apparatus and method for nanoflow liquid jet and serial femtosecond x-ray protein crystallography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bogan, Michael J.; Laksmono, Hartawan; Sierra, Raymond G.
Techniques for nanoflow serial femtosecond x-ray protein crystallography include providing a sample fluid by mixing a plurality of a first target of interest with a carrier fluid and injecting the sample fluid into a vacuum chamber at a rate less than about 4 microliters per minute. In some embodiments, the carrier fluid has a viscosity greater than about 3 centipoise.
76 FR 32390 - Motor Carrier Safety Advisory Committee Public Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-06
... Measurement System (SafeStat), CSMS quantifies the on-road safety performance of carriers to identify... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration [Docket No. FMCSA-2006-26367] Motor Carrier Safety Advisory Committee Public Meeting AGENCY: Federal Motor Carrier Safety...
Kato, Hiroshi; Nakagawa, Kan-Ichi
2010-01-01
Core carrier techniques are unique among the various root canal filling techniques for delivering and compacting gutta-percha in the prepared root canal system. Thermafil (TF), considered the major core carrier device, is provided as an obturator consisting of a master core coated with thermoplasticized gutta-percha. We have devised a thermoplasticized gutta-percha filling technique using a polypropylene core, FlexPoint® NEO (FP), which was developed as a canal filling material that can be sterilized in an autoclave. Therefore, FP can be coated onto thermoplasticized gutta-percha and inserted into the prepared canal as a core carrier. The FP core carrier technique offers many advantages over the TF system: the core can be tested in the root canal and verified radiographically; the core can be adjusted to fit and surplus material easily removed; furthermore the core can be easily removed for retreatment. The clinical procedure of the FP core carrier technique is simple, and similar that with the TF system. Thermoplasticized gutta-percha in a syringe is heated in an oven and extruded onto the FP core carrier after a trial insertion. The FP core carrier is inserted into the root canal to the working length. Excess FP is then removed with a red-hot plastic instrument at the orifice of the root canal. The FP core carrier technique incorporates the clinical advantages of the existing TF system while minimizing the disadvantages. Hence the FP core carrier technique is very useful in clinical practice. This paper describes the FP core carrier technique as a new core based method.
Pantub, Ketrawee; Wongtrakul, Paveena; Janwitayanuchit, Wicharn
2017-01-01
Nanostructured lipid carriers loaded salicylic acid (NLCs-SA) were developed and optimized by using the design of experiment (DOE). Box-Behnken experimental design of 3-factor, 3-level was applied for optimization of nanostructured lipid carriers prepared by emulsification method. The independent variables were total lipid concentration (X 1 ), stearic acid to Lexol ® GT-865 ratio (X 2 ) and Tween ® 80 concentration (X 3 ) while the particle size was a dependent variable (Y). Box-Behnken design could create 15 runs by setting response optimizer as minimum particle size. The optimized formulation consists of 10% of total lipid, a mixture of stearic acid and capric/caprylic triglyceride at a 4:1 ratio, and 25% of Tween ® 80 which the formulation was applied in order to prepare in both loaded and unloaded salicylic acid. After preparation for 24 hours, the particle size of loaded and unloaded salicylic acid was 189.62±1.82 nm and 369.00±3.37 nm, respectively. Response surface analysis revealed that the amount of total lipid is a main factor which could affect the particle size of lipid carriers. In addition, the stability studies showed a significant change in particle size by time. Compared to unloaded nanoparticles, the addition of salicylic acid into the particles resulted in physically stable dispersion. After 30 days, sedimentation of unloaded lipid carriers was clearly observed. Absolute values of zeta potential of both systems were in the range of 3 to 18 mV since non-ionic surfactant, Tween ® 80, providing steric barrier was used. Differential thermograms indicated a shift of endothermic peak from 55°C for α-crystal form in freshly prepared samples to 60°C for β´-crystal form in storage samples. It was found that the presence of capric/caprylic triglyceride oil could enhance encapsulation efficiency up to 80% and facilitate stability of the particles.
NASA Astrophysics Data System (ADS)
Takeuchi, Hideo; Yamamoto, Yoshitsugu; Kamo, Yoshitaka; Kunii, Tetsuo; Oku, Tomoki; Shirahama, Takeo; Tanaka, Hiroyasu; Nakayama, Masaaki
2007-08-01
We demonstrate that photoluminescence-excitation (PLE) spectroscopy can probe with high sensitivity the effects of plasma-induced surface damages on photogenerated-carrier-transport processes in AlxGa1-xN/GaN heterostructures, on the basis of systematic optical and structural characterization results for the as-grown reference sample and the plasma-exposed sample. It is found from the structural characterizations with atomic force microscopy that the plasma exposure remarkably modifies the atomic step boundaries and the pits on the AlxGa1-xN surface, which leads to a remarkable difference between the PLE spectra of the bound exciton photoluminescence from the underlying GaN layer in the two samples. The PLE spectrum of the reference sample shows a step rising from the AlxGa1-xN fundamental transition energy toward the high energy side, whereas the rising step disappears in the PLE spectrum of the plasma-exposed sample. In contrast, the reflectance characteristics are the same in the two samples; i.e., the excitonic transition itself is not influenced by the plasma exposure. The present findings indicate that the PLE spectral profile is sensitive to the change in efficiency of the photogenerated carrier injection from the AlxGa1-xN layer to the GaN layer. Thus, it is concluded that the PLE characterization is effective to probe the photogenerated-carrier transport in heterostructures.
First description of Cryptosporidium parvum in carrier pigeons (Columba livia).
Oliveira, Bruno César Miranda; Ferrari, Elis Domingos; da Cruz Panegossi, Mariele Fernanda; Nakamura, Alex Akira; Corbucci, Flávio Sader; Nagata, Walter Bertequini; Dos Santos, Bianca Martins; Gomes, Jancarlo Ferreira; Meireles, Marcelo Vasconcelos; Widmer, Giovanni; Bresciani, Katia Denise Saraiva
2017-08-30
The carrier pigeon and the domestic pigeon are different breeds of the species Columba livia. Carrier pigeons are used for recreational activities such as bird contests and exhibitions. Due to the close contact with humans, these birds may potentially represent a public health risk, since they can host and disseminate zoonotic parasites, such as those belonging to the genus Cryptosporidium (phylum Apicomplexa). The purpose of this work was the detection by microscopic and molecular techniques of Cryptosporidium spp. oocysts in fecal samples of carrier pigeons, and subsequently to sequence the 18S ribosomal RNA marker of positive samples to identify the species. A total of 100 fecal samples were collected individually in two pigeon breeding facilities from Formiga and Araçatuba, cities located in Minas Gerais state and São Paulo state, Brazil, respectively. The age of the birds ranged from one to 12 years; 56 were females and 44 males. Fecal smears were stained with negative malachite green, whereas the molecular characterization was based on the sequence of a ∼800bp fragment of the 18S rRNA gene. Microscopic examination of fecal smears revealed 4% (4/100) oocyst positivity. On the other hand, 7% (7/100) of positivity were found using nested PCR. Three samples were 99% to 100% similar to Cryptosporidium parvum 18S rDNA type A (Genbank AH006572) and the other three samples had 99% to 100% similarity to C. parvum 18S rDNA type B (Genbank AF308600). To our knowledge, this is the first report of C. parvum oocysts in carrier pigeons. Copyright © 2017 Elsevier B.V. All rights reserved.
Skutan, Stefan; Aschenbrenner, Philipp
2012-12-01
Components with extraordinarily high analyte contents, for example copper metal from wires or plastics stabilized with heavy metal compounds, are presumed to be a crucial source of errors in refuse-derived fuel (RDF) analysis. In order to study the error generation of those 'analyte carrier components', synthetic samples spiked with defined amounts of carrier materials were mixed, milled in a high speed rotor mill to particle sizes <1 mm, <0.5 mm and <0.2 mm, respectively, and analyzed repeatedly. Copper (Cu) metal and brass were used as Cu carriers, three kinds of polyvinylchloride (PVC) materials as lead (Pb) and cadmium (Cd) carriers, and paper and polyethylene as bulk components. In most cases, samples <0.2 mm delivered good recovery rates (rec), and low or moderate relative standard deviations (rsd), i.e. metallic Cu 87-91% rec, 14-35% rsd, Cd from flexible PVC yellow 90-92% rec, 8-10% rsd and Pb from rigid PVC 92-96% rec, 3-4% rsd. Cu from brass was overestimated (138-150% rec, 13-42% rsd), Cd from flexible PVC grey underestimated (72-75% rec, 4-7% rsd) in <0.2 mm samples. Samples <0.5 mm and <1 mm spiked with Cu or brass produced errors of up to 220% rsd (<0.5 mm) and 370% rsd (<1 mm). In the case of Pb from rigid PVC, poor recoveries (54-75%) were observed in spite of moderate variations (rsd 11-29%). In conclusion, time-consuming milling to <0.2 mm can reduce variation to acceptable levels, even given the presence of analyte carrier materials. Yet, the sources of systematic errors observed (likely segregation effects) remain uncertain.
Berah, Razieh; Ghorbani, Mohsen; Moghadamnia, Ali Akbar
2017-06-01
To create facile external controlled drug delivery system, a magnetic porous carrier based on Tin oxide nanoparticles was synthesized by an inexpensive and versatile hydrothermal strategy and used for in-vitro process. Magnetic nanocomposites were qualified by Fourier Transform Infrared (FTIR), Scanning Electron Microscopy (SEM), X-Ray Diffraction (XRD), Vibrational Sample Magnetometer (VSM) and Transmission Electron Microscopy (TEM). Results showed that nanoparticles were synthesized successfully with good dispersion of magnetic nanoparticles in cavity, uniform particle size distribution with average size of 65nm and high magnetization of 33.75 emu/mg. Furthermore, the nano-porosity and magnetism allowed high efficiency and remote controlled drug release. In this study, anti-migraine Sumatriptan was used as drug sample and the effect of drug concentration, Fe/Sn ratio and loading time on drug absorption were investigated. The best result was checked for stability at body temperature and different body pH. The sample with drug concentration of 0.25(mg/ml), Fe/Sn=0.22 and loading time of 1.5h had the highest drug efficiency (70%). Finally, in order to simulate the in vivo process for in-vitro step, Amnion was used and drug diffusion rate was measured in different intervals and different pH values. The result illustrated that after 25h, diffusion reached 65% at pH=2 and 56% at pH=7, and then became constant. Based on the above mentioned results, the carrier has an acceptable in vitro yield and therefore could be chosen for future in vivo researches. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Lauer, H. V., Jr.; Ming, Douglas W.; Golden, D. C.; Boynton, W. V.
2006-01-01
The Thermal and Evolved Gas Analyzer (TEGA) instrument scheduled to fly onboard the 2007 Mars Phoenix Scout Mission will perform differential scanning calorimetry (DSC) and evolved gas analysis (EGA) of soil samples and ice collected from the surface and subsurface at a northern landing site on Mars. We have been developing a sample characterization data library using a laboratory DSC integrated with a quadrupole mass spectrometer to support the interpretations of TEGA data returned during the mission. The laboratory TEGA test-bed instrument has been modified to operate under conditions similar to TEGA, i.e., reduced pressure (e.g., 100 torr) and reduced carrier gas flow rates. We have previously developed a TEGA data library for a variety of volatile-bearing mineral phases, including Fe-oxyhydroxides, phyllosilicates, carbonates, and sulfates. Here we examine the thermal and evolved gas properties of samples that contain organics. One of the primary objectives of the Phoenix Scout Mission is to search for habitable zones by assessing organic or biologically interesting materials in icy soil. Nitrogen is currently the carrier gas that will be used for TEGA. In this study, we examine two possible modes of detecting organics in geologic samples; i.e., pyrolysis using N2 as the carrier gas and combustion using O2 as the carrier gas.
Drug loaded silica coated MnFe2O4 ferromagnetic biomaterials for targeted cancer treatment
NASA Astrophysics Data System (ADS)
Anand, Vikas; Singh, K. J.; Kaur, Kulwinder; Bhatia, Gaurav
2017-05-01
Magnetically attracted silica coated MnFe2O4 samples have been prepared by using co-precipitation method. Structural changes have been confirmed from XRD spectra. Ferromagnetic behavior of samples has been studied by using vibration sample magnetometer. Cytotoxicity and cell culture of samples have been investigated by using human MG63 cell line and found that sample provide a healthy environment to the growth of cell lines. Drug carrier ability of sample has been checked with gentamycin as an antibiotic and results show that sample can be used as excellent drug carriers. Drug loaded samples can be easily targeted to specific area due to their attractive nature towards external magnetic field. Moreover, magnetic nanoparticles can also be used to kill the cancer cells by using hyperthermia technique. Hyperthermia is a process to raise the temperature of surrounding cells in the presence of external AC magnetic field above the maximum temperature limit for surviving of the cancer cells. Cancer cell can survive only up to 47°C. After that cancer cells start to die, but healthy cells can easily survive up to higher temperature. Our results indicate that prepared samples possess good drug carrier ability and hence, can be potential candidates for cancer cell treatment.
DOT National Transportation Integrated Search
2010-04-01
This project provides an independent evaluation of a commercially available low-cost driving behavior management system. Participating drivers from two carriers (identified as Carrier A and Carrier B) drove an instrumented vehicle for 17 consecutive ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sellers, D. G.; Chen, E. Y.; Doty, M. F.
2016-05-21
We investigate the effect of doping on the mechanisms of carrier escape from intermediate states in delta-doped InAs/GaAs intermediate band solar cells. The intermediate states arise from InAs quantum dots embedded in a GaAs p-i-n junction cell. We find that doping the sample increases the number of excited-state carriers participating in a cycle of trapping and carrier escape via thermal, optical, and tunneling mechanisms. However, we find that the efficiency of the optically-driven carrier escape mechanism is independent of doping and remains small.
Auger heating of carriers in {GaAs}/{AlAs} heterostructures
NASA Astrophysics Data System (ADS)
Borri, P.; Ceccherini, S.; Gurioli, M.; Bogani, F.
1997-07-01
The photoluminescence of {GaAs}/{AlAs} multiple quantum wells structures under optical ps excitation is investigated for carrier densities in the range 10 18-4 × 10 19 cm -3 with frequency and time-resolved spectroscopic techniques. The measurements give a direct evidence of the occurrence in the sample of carrier heating. This energy up-conversion gives rise to photoluminescence from the states near the Fermi level whose intensity and time evolution depend on the carrier density in a strongly non-linear way. The observed behaviour can be explained introducing in the carrier dynamics an up-conversion mechanism due to Auger-like processes.
14 CFR 04 - Air Carrier Groupings
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 4 2012-01-01 2012-01-01 false Air Carrier Groupings Section 04 Section... PROCEEDINGS) ECONOMIC REGULATIONS UNIFORM SYSTEM OF ACCOUNTS AND REPORTS FOR LARGE CERTIFICATED AIR CARRIERS Section 04 Air Carrier Groupings (a) All large certificated air carriers are placed into three basic air...
TOPICAL REVIEW: Experimental study of organic zero-gap conductor α-(BEDT-TTF)2I3
NASA Astrophysics Data System (ADS)
Tajima, Naoya; Kajita, Koji
2009-04-01
A zero-gap state with a Dirac cone type energy dispersion was discovered in the organic conductor α-(BEDT-TTF)2I3 under high hydrostatic pressures. This is the first two-dimensional (2D) zero-gap state discovered in bulk crystals with a layered structure. In contrast to the case of graphene, the Dirac cone in this system is highly anisotropic. The present system, therefore, provides a new type of massless Dirac fermion system with anisotropic Fermi velocity. This system exhibits remarkable transport phenomena characteristic to electrons on the Dirac cone type energy structure. The carrier density, written as n~T2, is a characteristic feature of the 2D zero-gap structure. On the other hand, the resistivity per layer (sheet resistance RS) is given as RS=h/e2 and is independent of temperature. The effect of a magnetic field on samples in the zero-gap system was examined. The difference between zero-gap conductors and conventional conductors is the appearance of a Landau level called the zero mode at the contact points when a magnetic field is applied normal to the conductive layer. Zero-mode Landau carriers give rise to strong negative out-of-plane magnetoresistance.
In vivo evaluation of a simvastatin-loaded nanostructured lipid carrier for bone tissue regeneration
NASA Astrophysics Data System (ADS)
Yue, Xinxin; Niu, Mao; Zhang, Te; Wang, Cheng; Wang, Zhonglei; Wu, Wangxi; Zhang, Qi; Lai, Chunhua; Zhou, Lei
2016-03-01
Alveolar bone loss has long been a challenge in clinical dental implant therapy. Simvastatin (SV) has been demonstrated to exert excellent anabolic effects on bone. However, the successful use of SV to increase bone formation in vivo largely depends on the local concentration of SV at the site of action, and there have been continuing efforts to develop an appropriate delivery system. Specifically, nanostructured lipid carrier (NLC) systems have become a popular type of encapsulation carrier system. Therefore, SV-loaded NLCs (SNs) (179.4 nm in diameter) were fabricated in this study, and the osteogenic effect of the SNs was evaluated in a critical-sized rabbit calvarial defect. Our results revealed that the SNs significantly enhanced bone formation in vivo, as evaluated by hematoxylin and eosin (HE) staining, immunohistochemistry, and a fluorescence analysis. Thus, this novel nanostructured carrier system could be a potential encapsulation carrier system for SV in bone regeneration applications.
Microwave heating of aqueous samples on a micro-optical-electro-mechanical system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beer, Neil Reginald
2016-04-12
Apparatus for heating a sample includes a microchip; a microchannel flow channel in the microchip, the microchannel flow channel containing the sample; a microwave source that directs microwaves onto the sample for heating the sample; a wall section of the microchannel flow channel that receives the microwaves and enables the microwaves to pass through wall section of the microchannel flow channel, the wall section the microchannel flow channel being made of a material that is not appreciably heated by the microwaves; a carrier fluid within the microchannel flow channel for moving the sample in the microchannel flow channel, the carriermore » fluid being made of a material that is not appreciably heated by the microwaves; wherein the microwaves pass through wall section of the microchannel flow channel and heat the sample.« less
Microwave heating of aqueous samples on a micro-optical-electro-mechanical system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beer, Neil Reginald
Apparatus for heating a sample includes a microchip; a microchannel flow channel in the microchip, the microchannel flow channel containing the sample; a microwave source that directs microwaves onto the sample for heating the sample; a wall section of the microchannel flow channel that receives the microwaves and enables the microwaves to pass through wall section of the microchannel flow channel, the wall section the microchannel flow channel being made of a material that is not appreciably heated by the microwaves; a carrier fluid within the microchannel flow channel for moving the sample in the microchannel flow channel, the carriermore » fluid being made of a material that is not appreciably heated by the microwaves; wherein the microwaves pass through wall section of the microchannel flow channel and heat the sample.« less
ERIC Educational Resources Information Center
Martin, Nicolas W.; Benyamin, Beben; Hansell, Narelle K.; Montgomery, Grant W.; Martin, Nicholas G.; Wright, Margaret J.; Bates, Timothy C.
2011-01-01
Objectives: Breast-fed C-allele carriers of the rs single nucleotide polymorphism in the fatty acyl desaturase 2 ("FADS2") gene have been reported to show a 6.4 to 7 IQ point advantage over formula-fed C-allele carriers, with no effect of breast-feeding in GG carriers. An Australian sample was examined to determine if an interaction between…
Park, Aesoon; Kim, Jueun; Zaso, Michelle J.; Glatt, Stephen J.; Sher, Kenneth J.; Scott-Sheldon, Lori A. J.; Eckert, Tanya L.; Vanable, Peter A.; Carey, Kate B.; Ewart, Craig K.; Carey, Michael P.
2015-01-01
Peer drinking norms are arguably one of the strongest correlates of adolescent drinking. Prospective studies indicate that adolescents tend to select peers based on drinking (peer-selection) and their peers’ drinking is associated with changes in adolescent drinking over time (peer socialization). The present study investigated whether the peer selection and socialization processes in adolescent drinking differed as a function of the DRD4 VNTR genotype in two independent prospective datasets. The first sample was 174 high school students drawn from a 2-wave 6-month prospective study. The second sample was 237 college students drawn from a 3-wave annual prospective study. Multigroup cross-lagged panel analyses of the high school student sample indicated stronger socialization via peer drinking norms among carriers, whereas analyses of the college student sample indicated stronger drinking-based peer selection in the junior year among carriers, compared to non-carriers. Although replication and meta-analytic synthesis are needed, these findings suggest in part genetically determined peer-selection (carriers of the DRD4 7-repeat allele tend to associate with peers who have more favorable attitudes toward drinking and greater alcohol use) and peer socialization (carriers’ subsequent drinking behaviors are more strongly associated with their peer drinking norms) may differ across adolescent developmental stages. PMID:26902782
[Drug delivery systems using nano-sized drug carriers].
Nakayama, Masamichi; Okano, Teruo
2005-07-01
Nanotechnology has attracted great attention all over the world in recent several years and has led to the establishment of the novel technical field of "nanomedicine" through collaboration with advanced medical technology. Particularly, site-specific drug targeting using particle drug carrier systems has made substantial progress and been actively developed. This review explains the essential factors (size and chemical character) of drug carriers to allow long circulation in the bloodstream avoiding the reticuloendothelial system, and shows the present status and future perspective of several types of nano-carrier systems (water-soluble polymer, liposome and polymeric micelle). We also introduce the novel concept of multi-targeting system (combination of two or more targeting methodologies) for ideal drug therapies.
48 CFR 1632.170 - Recurring premium payments to carriers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... multiplied by the carrier's total net-to-carrier premium dollars paid for the preceding contract period. The... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Recurring premium payments... FINANCING General 1632.170 Recurring premium payments to carriers. (a)(1) Recurring payments to carriers of...
Unmanned Carrier-Based Aircraft System: Debate over Systems Role Led to Focus on Aerial Refueling
2016-03-24
Unmanned Carrier-Based Aircraft System: Debate over System’s Role Led to Focus on Aerial Refueling Prior to February 2016, the Navy had planned to...award of the air system development contract by about 3 years from 2014 to 2017. In that report, we also found that knowledge the Navy had obtained...strike 1Pub. L. No. 113-66, § 213(d) (2013). 2GAO, Unmanned Carrier-Based Aircraft System: Navy Needs
Vinkers, Christiaan H; Joëls, Marian; Milaneschi, Yuri; Gerritsen, Lotte; Kahn, René S; Penninx, Brenda W J H; Boks, Marco P M
2015-04-01
The MR is an important regulator of the hypothalamic-pituitary-adrenal (HPA) axis and a prime target for corticosteroids. There is increasing evidence from both clinical and preclinical studies that the MR has different effects on behavior and mood in males and females. To investigate the hypothesis that the MR sex-dependently influences the relation between childhood maltreatment and depression, we investigated three common and functional MR haplotypes (GA, CA, and CG haplotype, based on rs5522 and rs2070951) in a population-based cohort (N = 665) and an independent clinical cohort from the Netherlands Study of Depression and Anxiety (NESDA) (N = 1639). The CA haplotype sex-dependently moderated the relation between childhood maltreatment and depressive symptoms both in the population-based sample (sex × maltreatment × haplotype: β = -4.07, P = 0.029) and in the clinical sample (sex × maltreatment × haplotype, β = -2.40, P = 0.011). Specifically, female individuals in the population-based sample were protected (β = -4.58, P = 2.0 e(-5)), whereas males in the clinical sample were at increased risk (β = 2.54, P = 0.0022). In line with these results, female GA haplotype carriers displayed increased vulnerability in the population-based sample (β = 4.58, P = 7.5 e(-5)) whereas male CG-carriers showed increased resilience in the clinical sample (β = -2.71, P = 0.016). Consistently, we found a decreased lifetime MDD risk for male GA haplotype carriers following childhood maltreatment but an increased risk for male CA haplotype carriers in the clinical sample. In both samples, sex-dependent effects were observed for GA-GA diplotype carriers. In summary, sex plays an important role in determining whether functional genetic variation in MR is beneficial or detrimental, with an apparent female advantage for the CA haplotype but male advantage for the GA and CG haplotype. These sex-dependent effects of MR on depression susceptibility following childhood maltreatment are relevant in light of the increased prevalence of mood disorders in women and point to a sex-specific role of MR in the etiology of depression following childhood maltreatment. Copyright © 2015 Elsevier Ltd. All rights reserved.
Ultrafast momentum imaging of pseudospin-flip excitations in graphene
NASA Astrophysics Data System (ADS)
Aeschlimann, S.; Krause, R.; Chávez-Cervantes, M.; Bromberger, H.; Jago, R.; Malić, E.; Al-Temimy, A.; Coletti, C.; Cavalleri, A.; Gierz, I.
2017-07-01
The pseudospin of Dirac electrons in graphene manifests itself in a peculiar momentum anisotropy for photoexcited electron-hole pairs. These interband excitations are in fact forbidden along the direction of the light polarization and are maximum perpendicular to it. Here, we use time- and angle-resolved photoemission spectroscopy to investigate the resulting unconventional hot carrier dynamics, sampling carrier distributions as a function of energy, and in-plane momentum. We first show that the rapidly-established quasithermal electron distribution initially exhibits an azimuth-dependent temperature, consistent with relaxation through collinear electron-electron scattering. Azimuthal thermalization is found to occur only at longer time delays, at a rate that depends on the substrate and the static doping level. Further, we observe pronounced differences in the electron and hole dynamics in n -doped samples. By simulating the Coulomb- and phonon-mediated carrier dynamics we are able to disentangle the influence of excitation fluence, screening, and doping, and develop a microscopic picture of the carrier dynamics in photoexcited graphene. Our results clarify new aspects of hot carrier dynamics that are unique to Dirac materials, with relevance for photocontrol experiments and optoelectronic device applications.
Rozenzon, Yan; Trujillo, Robert T; Beese, Steven C
2013-10-22
One embodiment of the present invention provides a wafer-carrier system used in a deposition chamber for carrying wafers. The wafer-carrier system includes a base susceptor and a top susceptor nested inside the base susceptor with its wafer-mounting side facing the base susceptor's wafer-mounting side, thereby forming a substantially enclosed narrow channel. The base susceptor provides an upward support to the top susceptor.
NASA Astrophysics Data System (ADS)
Otsuka, Mioko; Homma, Ryoei; Hasegawa, Yasuhiro
2017-05-01
The phonon and carrier thermal conductivities of thermoelectric materials were calculated using the Wiedemann-Franz law, Boltzmann equation, and a method we propose in this study called the Debye specific heat method. We prepared polycrystalline n-type doped bismuth telluride (BiTe) and bismuth antimony (BiSb) bulk alloy samples and measured six parameters (Seebeck coefficient, resistivity, thermal conductivity, thermal diffusivity, magneto-resistivity, and Hall coefficient). The carrier density and mobility were estimated for calculating the carrier thermal conductivity by using the Boltzmann equation. In the Debye specific heat method, the phonon thermal diffusivity, and thermal conductivity were calculated from the temperature dependence of the effective specific heat by using not only the measured thermal conductivity and Debye model, but also the measured thermal diffusivity. The carrier thermal conductivity was also evaluated from the phonon thermal conductivity by using the specific heat. The ratio of carrier thermal conductivity to thermal conductivity was evaluated for the BiTe and BiSb samples, and the values obtained using the Debye specific heat method at 300 K were 52% for BiTe and <5.5% for BiSb. These values are either considerably larger or smaller than those obtained using other methods. The Dulong-Petit law was applied to validate the Debye specific heat method at 300 K, which is significantly greater than the Debye temperature of the BiTe and BiSb samples, and it was confirmed that the phonon specific heat at 300 K has been accurately reproduced using our proposed method.
Improved electrical properties of n-type SiGe alloys
NASA Technical Reports Server (NTRS)
Scoville, A. N.; Bajgar, Clara; Vandersande, Jan; Fleurial, Jean-Pierre
1992-01-01
The effect of changes in the carrier concentration and mobility for heavily doped n-type SiGe on the electrical power factor has been investigated. It has been shown that power factors of 37-40 microV/cm-K-squared can be achieved with carrier concentrations of 2.0 - 2.5 x 10 exp 20/cu cm and mobilities of 38-40 sq cm/V-sec. Many samples with suitable carrier concentration do not have high mobilities and some rationale for this behavior is presented. Initial results are presented on fabrication of n-type samples from ultrafine powders. The emphasis in this work is to achieve thermal conductivity reductions by adding inert particles to scatter midfrequency phonons.
Central circuitry in the jellyfish Aglantha. II: The ring giant and carrier systems
Mackie; Meech
1995-01-01
1. The ring giant axon in the outer nerve ring of the jellyfish Aglantha digitale is a multinucleate syncytium 85 % of which is occupied by an electron-dense fluid-filled vacuole apparently in a GibbsDonnan equilibrium with the surrounding band of cytoplasmic cortex. Micropipette recordings show small (-15 to -25 mV) and large (-62 to -66 mV) resting potentials. Low values, obtained with a high proportion of the micropipette penetrations, are assumed to be from the central vacuole; high values from the cytoplasmic cortex. Background electrical activity includes rhythmic oscillations and synaptic potentials representing hair cell input caused by vibration. 2. After the ring giant axon has been cut, propagating action potentials evoked by stimulation are conducted past the cut and re-enter the axon on the far side. The system responsible (the carrier system) through-conducts at a velocity approximately 25 % of that of the ring giant axon and is probably composed of small neurones running in parallel with it. Numerous small neurones are seen by electron microscopy, some making one-way and some two-way synapses with the ring giant. 3. Despite their different conduction velocities, the two systems normally appear to fire in synchrony and at the velocity of the ring giant axon. We suggest that, once initiated, ring giant spikes propagate rapidly around the margin, firing the carrier neurones through serial synapses and giving them, in effect, the same high conduction velocity. Initiation of ring giant spikes can, however, require input from the carrier system. The spikes are frequently seen to be mounted on slow positive potentials representing summed carrier postsynaptic potentials. 4. The carrier system fires one-for-one with the giant axons of the tentacles and may mediate impulse traffic between the latter and the ring giant axon. We suggest that the carrier system may also provide the pathways from the ring giant to the motor giant axons used in escape swimming. 5. The findings show that the ring giant axon functions in close collaboration with the carrier system, increasing the latter's effective conduction velocity, and that interactions with other neuronal sub-systems are probably mediated exclusively by the carrier system.
48 CFR 1615.470 - Carrier investment of FEHB funds.
Code of Federal Regulations, 2011 CFR
2011-10-01
... CONTRACTING BY NEGOTIATION Contract Pricing 1615.470 Carrier investment of FEHB funds. (a) Except for... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Carrier investment of FEHB funds. 1615.470 Section 1615.470 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT...
Zhao, Yonggui; Fang, Yang; Jin, Yanling; Huang, Jun; Ma, Xinrong; He, Kaize; He, Zhiming; Wang, Feng; Zhao, Hai
2015-03-01
Carriers were added to a pilot-scale duckweed-based (Lemna japonica 0223) wastewater treatment system to immobilize and enhance microorganisms. This system and another parallel duckweed system without carriers were operated for 1.5 years. The results indicated the addition of the carrier did not significantly affect the growth and composition of duckweed, the recovery of total nitrogen (TN), total phosphorus (TP) and CO2 or the removal of TP. However, it significantly improved the removal efficiency of TN and NH4(+)-N (by 19.97% and 15.02%, respectively). The use of 454 pyrosequencing revealed large differences of the microbial communities between the different components within a system and similarities within the same components between the two systems. The carrier biofilm had the highest bacterial diversity and relative abundance of nitrifying bacteria (3%) and denitrifying bacteria (24% of Rhodocyclaceae), which improved nitrogen removal of the system. An efficient N-removal duckweed system with enhanced microorganisms was established. Copyright © 2014 Elsevier Ltd. All rights reserved.
Dong, Danfeng; Ni, Qi; Wang, Chen; Zhang, Lihua; Li, Zhen; Jiang, Cen; EnqiangMao; Peng, Yibing
2018-05-03
Intestinal colonization by pathogenic bacteria is a risk factor for infection, and contributes to environmental contamination and disease dissemination. Alteration of gut microbiota also plays a pivotal role in the development of disease. Although Clostridium difficile and Staphylococcus aureus are well-recognized pathogens causing nosocomial and community infections, the intestinal colonization was not fully investigated. Herein, we explored their overall carriage rates in healthy adults from the community, and characterized the gut microbiomes of C. difficile and S. aureus carriers. Fecal samples were collected from 1709 healthy volunteers from communities in Shanghai, China, and tested for the presence of C. difficile, methicillin-sensitive S. aureus (MSSA), and methicillin-resistant S. aureus (MRSA) using culture-based techniques. To explore differences in the gut microbiome, 16S rRNA gene sequencing was conducted using samples from non-carriers (CH), C. difficile carriers (CCD), MRSA carriers (CM), and MSSA carriers (CS). Overall, we detected 12 C. difficile and 60 S. aureus isolates, accounting for 0.70% and 3.51% of total isolates, respectively. Eight isolates were determined to be MRSA, accounting for 13.3% of the S. aureus population. Sequencing data revealed that the microbial diversity and richness were similar among the four groups. However, at the phylum level, carriage of C. difficile or MRSA was associated with a paucity of Bacteroidetes and an overabundance of Proteobacteria compared with non-carriers. At the genus level, the prevalence of the genera Bacteroides, Prevotella, Faecalibacterium, and Roseburia was decreased in C. difficile-positive samples compared with the controls, while the proportion of Clostridium cluster XIVa species was increased. MRSA carriers exhibited a higher proportion of the genera Parasutterella and Klebsiella, but a decreased prevalence of Bacteroides. Compared with MSSA carriers, Klebsiella was the only genus found to be significantly enriched in MRSA carriers. In healthy adults, colonization by C. difficile or S. aureus did not significantly affect gut microbiota diversity. However, the alteration of the gut microbiota composition in C. difficile carriers could indicate a predisposition to further infection. Our study provides essential data on the prevalence and effects of C. difficile and S. aureus colonization on gut microbiota composition in healthy adults.
Role of Adsorbed Water on Charge Carrier Dynamics in Photoexcited TiO2
2017-01-01
Overall photocatalytic water splitting is one of the most sought after processes for sustainable solar-to-chemical energy conversion. The efficiency of this process strongly depends on charge carrier recombination and interaction with surface adsorbates at different time scales. Here, we investigated how hydration of TiO2 P25 affects dynamics of photogenerated electrons at the millisecond to minute time scale characteristic for chemical reactions. We used rapid scan diffuse-reflectance infrared Fourier transform spectroscopy (DRIFTS). The decay of photogenerated electron absorption was substantially slower in the presence of associated water. For hydrated samples, the charge carrier recombination rates followed an Arrhenius-type behavior in the temperature range of 273–423 K; these became temperature-independent when the material was dehydrated at temperatures above 423 K or cooled below 273 K. A DFT+U analysis revealed that hydrogen bonding with adsorbed water stabilizes surface-trapped holes at anatase TiO2(101) facet and lowers the barriers for hole migration. Hence, hole mobility should be higher in the hydrated material than in the dehydrated system. This demonstrates that adsorbed associated water can efficiently stabilize photogenerated charge carriers in nanocrystalline TiO2 and suppress their recombination at the time scale up to minutes. PMID:28413570
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, Sung Su
1993-09-01
Ion-induced conductivity has been used to investigate the detector characteristics of diamond detectors. Both integrated-charge, and time-resolved current measurements were performed to examine the mean carrier transport properties of diamond and the dynamics of charge collection under highly-localized and high-density excitation conditions. The integrated-charge measurements were conducted with a standard pulse-counting system with 241Am radioactivity as the excitation source for the detectors. The time-resolved current measurements were performed using a 70 GHz random sampling oscilloscope with the detectors incorporated into high-speed microstrip transmission lines and the excitation source for these measurements was an ion beam of either 5-MeV He +more » or 10-MeV Si 3+. The detectors used in both experiments can be described as metal-semiconductor-metal (MSM) devices where a volume of the detector material is sandwiched between two metal plates. A charge collection model was developed to interpret the integrated-charge measurements which enabled estimation of the energy required to produce an electron-hole pair (ϵ di) and the mean carrier transport properties in diamond, such as carrier mobility and lifetime, and the behavior of the electrical contacts to diamond.« less
Karavasili, Christina; Amanatiadou, Elsa P; Kontogiannidou, Eleni; Eleftheriadis, Georgios K; Bouropoulos, Nikolaos; Pavlidou, Eleni; Kontopoulou, Ioanna; Vizirianakis, Ioannis S; Fatouros, Dimitrios G
2017-08-07
Microporous zeolites of distinct framework types, textural properties and crystal morphologies namely BEA, ZSM and NaX, have been employed as carriers to assess their effect on modulating the dissolution behavior of a BCS II model drug (indomethacin). Preparation of the loaded carriers via the incipient wetness method induced significant drug amorphization for the BEA and NaX samples, as well as high drug payloads. The stability of the amorphous drug content was retained after stressing test evaluation of the porous carriers. The dissolution profile of loaded indomethacin was evaluated in simulated gastric fluid (pH 1.2) and simulated intestinal fluids FaSSIF (fasted) and FeSSIF (fed state) conditions and was found to be dependent on the aluminosilicate ratio of the zeolites and the degree of crystalline drug content. The feasibility of the zeolitic particles as oral drug delivery systems was appraised with cytocompatibility and cellular toxicity studies in Caco-2 cultures in a time- and dose-dependent manner by means of the MTT assay and flow cytometry analysis, respectively. Intracellular accumulation of the zeolite particles was observed with no apparent cytotoxic effects at the lower concentrations tested, rendering such microporous zeolites pertinent candidates in oral drug delivery applications. Copyright © 2017 Elsevier B.V. All rights reserved.
Sun, Xiaoqiang; Ma, Ren; Jiang, Yali; Gao, Yidian; Ming, Qingsen; Wu, Qiong; Dong, Daifeng; Wang, Xiang; Yao, Shuqiao
2018-05-31
Conduct disorder (CD), a common psychiatric disorder in children and adolescents, is characterized by encroaching upon other rights and violations of age-appropriate social expectations repeatedly and persistently. Individuals with CD often have high aggressiveness and low inhibitory capacity. The monoamine oxidase A (MAOA) gene has long been associated with aggression. Effects of MAOA genotype on inhibitory control have been examined in general population. Several studies had revealed reduced activation in prefrontal areas, especially the anterior cingulate cortex (ACC), in low-expression MAOA (MAOA-L) allele carriers compared to high-expression MAOA (MAOA-H) allele carriers. However, little is known about its genetic risk influences on inhibitory processes in clinical samples. In this study, functional magnetic resonance imaging (fMRI) was administered to a sample of adolescent boys with CD during the performance of a GoStop task, 29 of whom carrying MAOA-L allele and 24 carrying MAOA-H allele. Relative to MAOA-H carriers, MAOA-L carriers in CD showed more pronounced deactivation in the precuneus, supplementary motor area (SMA) and dorsal anterior cingulate cortex (dACC). Deactivation within the default mode network (DMN) and inhibitory-related areas in MAOA-L carriers may be related to compensation for low sensitivity to inhibition and/or an atypical allocation of cognitive resources. The results suggested a possible neural mechanism through which MAOA affects inhibitory processes in a clinical sample.
2014-10-01
rectus abdominal muscle, autotransplantation, heterotopic, superior epigastric vein, cold ischemia time, immunomodulation, transcriptomics...composite flap (muscle, adipose tissue and skin) from the whole rectus abdominal muscle (RAM). This model was maximized through extensive anatomical...The biopsies included Skin - Subcutaneous Fat – Muscle. (9 tissue samples per each biopsy time point for each flap) The biopsies were taken by punches
Polymorphisms of the OXTR gene explain why sales professionals love to help customers
Verbeke, Willem; Bagozzi, Richard P.; van den Berg, Wouter E.; Lemmens, Aurelie
2013-01-01
Polymorphisms of the OXTR gene affect people's social interaction styles in various social encounters: carriers of the OXTR GG, compared to the OXTR AA/AG in general, are more motivated to interact socially and detect social salience. We focus on sales professionals operating in knowledge intensive organizations. Study 1, with a sample of 141 sales people, shows that carriers of the OXTR GG allele, compared to the OXTR AA/AG allele, are more motivated to help customers than to manipulatively impose goods/services on them. Study 2, using genomic functional magnetic resonance imaging (fMRI) on a sample of 21 sales professionals processing facial pictures with different emotional valences, investigates key nuclei of social brain regions (SBRs). Compared to OXTR AA/AG carriers, OXTR GG carriers experience greater effective connectivity between SBRs of interest measured by Granger causality tests using univariate Haugh tests. In addition, the multivariate El-Himdi and Roy tests demonstrate that the amygdala, prefrontal cortex, and pars opercularis (inferior frontal gyrus) play key roles when processing emotional expressions. The bilateral amygdala and medial prefrontal cortex (mPFC) show significantly greater clout—influence on other brain regions—for GG allele carriers than non-carriers; likewise, the bilateral pars opercularis, left amygdala, and left mPFC are more receptive to activity in other brain regions among GG allele carriers than AG/AA allele carriers are. Thus, carriers of the OXTR GG allele are more sensitive to changes in emotional cues, enhancing social salience. To our knowledge, this is the first study on how insights from imaging genetics help understanding of the social motivation of people operating in a professional setting. PMID:24348351
Polymorphisms of the OXTR gene explain why sales professionals love to help customers.
Verbeke, Willem; Bagozzi, Richard P; van den Berg, Wouter E; Lemmens, Aurelie
2013-01-01
Polymorphisms of the OXTR gene affect people's social interaction styles in various social encounters: carriers of the OXTR GG, compared to the OXTR AA/AG in general, are more motivated to interact socially and detect social salience. We focus on sales professionals operating in knowledge intensive organizations. Study 1, with a sample of 141 sales people, shows that carriers of the OXTR GG allele, compared to the OXTR AA/AG allele, are more motivated to help customers than to manipulatively impose goods/services on them. Study 2, using genomic functional magnetic resonance imaging (fMRI) on a sample of 21 sales professionals processing facial pictures with different emotional valences, investigates key nuclei of social brain regions (SBRs). Compared to OXTR AA/AG carriers, OXTR GG carriers experience greater effective connectivity between SBRs of interest measured by Granger causality tests using univariate Haugh tests. In addition, the multivariate El-Himdi and Roy tests demonstrate that the amygdala, prefrontal cortex, and pars opercularis (inferior frontal gyrus) play key roles when processing emotional expressions. The bilateral amygdala and medial prefrontal cortex (mPFC) show significantly greater clout-influence on other brain regions-for GG allele carriers than non-carriers; likewise, the bilateral pars opercularis, left amygdala, and left mPFC are more receptive to activity in other brain regions among GG allele carriers than AG/AA allele carriers are. Thus, carriers of the OXTR GG allele are more sensitive to changes in emotional cues, enhancing social salience. To our knowledge, this is the first study on how insights from imaging genetics help understanding of the social motivation of people operating in a professional setting.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanulik, J.
1983-09-20
A sample-taking appliance comprises several sensors arranged on a turntable like sensor carrier in such a manner that the application areas of the small sensor sponges decrease stepwise from the first to the last sensor. By simple rotation of the turntable the sensors can be brought successively into a working position. The sensor carrier is preferably accommodated in a housing which is open at the bottom and which is raisable and lowerable in the frame of the appliance by, for example, a threaded spindle. The threaded spindle is driven by an electric motor. For each sampling the sensor carrier ismore » lowered until the cell voltage corresponds to a predetermined desired value. This produces sufficiently precise and reproductible measured values of the electrolytic current for ascertaining the removed layer thickness. The appliance makes it possible to take material samples even from locations of high radiation loading. The material layers removed as samples lie concentrically above each other so that the graduation of the application areas comes into full effect and the material samples taken by the small sponges and the radioactivity contained therein are not falsified.« less
Digital signal processor and processing method for GPS receivers
NASA Technical Reports Server (NTRS)
Thomas, Jr., Jess B. (Inventor)
1989-01-01
A digital signal processor and processing method therefor for use in receivers of the NAVSTAR/GLOBAL POSITIONING SYSTEM (GPS) employs a digital carrier down-converter, digital code correlator and digital tracking processor. The digital carrier down-converter and code correlator consists of an all-digital, minimum bit implementation that utilizes digital chip and phase advancers, providing exceptional control and accuracy in feedback phase and in feedback delay. Roundoff and commensurability errors can be reduced to extremely small values (e.g., less than 100 nanochips and 100 nanocycles roundoff errors and 0.1 millichip and 1 millicycle commensurability errors). The digital tracking processor bases the fast feedback for phase and for group delay in the C/A, P.sub.1, and P.sub.2 channels on the L.sub.1 C/A carrier phase thereby maintaining lock at lower signal-to-noise ratios, reducing errors in feedback delays, reducing the frequency of cycle slips and in some cases obviating the need for quadrature processing in the P channels. Simple and reliable methods are employed for data bit synchronization, data bit removal and cycle counting. Improved precision in averaged output delay values is provided by carrier-aided data-compression techniques. The signal processor employs purely digital operations in the sense that exactly the same carrier phase and group delay measurements are obtained, to the last decimal place, every time the same sampled data (i.e., exactly the same bits) are processed.
The effect of carrier type on bone regeneration of demineralized bone matrix in vivo.
Tavakol, Shima; Khoshzaban, Ahad; Azami, Mahmoud; Kashani, Iraj Ragerdi; Tavakol, Hani; Yazdanifar, Mahbube; Sorkhabadi, Seyed Mahdi Rezayat
2013-11-01
Demineralized bone matrix (DBM) is a bone substitute biomaterial used as an excellent grafting material. Some factors such as carrier type might affect the healing potential of this material. The background data discuss the present status of the field: Albumin as a main protein in blood and carboxymethyl cellulose (CMC) were applied frequently in the DBM gels. We investigated the bone-repairing properties of 2 DBMs with different carriers. Bone regeneration in 3 groups of rat calvaria treated with DBM from the Iranian Tissue Bank Research and Preparation Center, DBM from Hans Biomed Corporation, and an empty cavity was studied. Albumin and CMC as carriers were used. The results of bone regeneration in the samples after 1, 4, and 8 weeks of implantation were compared. The block of the histologic samples was stained with hematoxylin and eosin, and the percentage area of bone formation was calculated using the histomorphometry method. The results of in vivo tests showed a significantly stronger new regenerated bone occupation in the DBM with albumin carrier compared with the one with CMC 8 weeks after the implantation. The 2 types of DBM had a significant difference in bone regeneration. This difference is attributed to the type of carriers. Albumin could improve mineralization and bioactivity compared with CMC.
Carrier recombination in mid-wave infrared InAs/InAsSb superlattices
NASA Astrophysics Data System (ADS)
Aytac, Yigit; Olson, Benjamin Varberg; Kim, Jin K.; Shaner, Eric A.; Hawkins, Sam D.; Klem, John F.; Flatté, Michael E.; Boggess, Thomas F.
2014-03-01
Measurements of carrier recombination rates using a temperature-dependent time-resolved differential transmission technique are reported for mid-wave infrared InAs / InAs1 - x Sbx type-2 superlattices (T2SLs). By engineering the layer widths and antimony compositions a 16K band-gap of ~ 238 meV was achieved for all five unintentionally doped T2SLs. Carrier recombination rates were determined for all five samples by fitting a rate equation model to the density and temperature dependent data. Minority-carrier lifetimes as long as 22 μs were measured at 14K, while lifetimes in excess of 2 μs were measured for all five samples at 200K. The minority-carrier lifetimes were observed to generally increase with increasing antimony content. While minority-carrier lifetimes are much longer than those observed in InAs/Ga(In)Sb T2SLs, Auger recombination processes were found to be more prominent in the Ga-free T2SLs. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under Contract No. DE-AC04-94AL85000. This research was funded by the U.S. Government.
System for characterizing semiconductor materials and photovoltaic devices through calibration
Sopori, Bhushan L.; Allen, Larry C.; Marshall, Craig; Murphy, Robert C.; Marshall, Todd
1998-01-01
A method and apparatus for measuring characteristics of a piece of material, typically semiconductor materials including photovoltaic devices. The characteristics may include dislocation defect density, grain boundaries, reflectance, external LBIC, internal LBIC, and minority carrier diffusion length. The apparatus includes a light source, an integrating sphere, and a detector communicating with a computer. The measurement or calculation of the characteristics is calibrated to provide accurate, absolute values. The calibration is performed by substituting a standard sample for the piece of material, the sample having a known quantity of one or more of the relevant characteristics. The quantity measured by the system of the relevant characteristic is compared to the known quantity and a calibration constant is created thereby.
System for characterizing semiconductor materials and photovoltaic devices through calibration
Sopori, B.L.; Allen, L.C.; Marshall, C.; Murphy, R.C.; Marshall, T.
1998-05-26
A method and apparatus are disclosed for measuring characteristics of a piece of material, typically semiconductor materials including photovoltaic devices. The characteristics may include dislocation defect density, grain boundaries, reflectance, external LBIC, internal LBIC, and minority carrier diffusion length. The apparatus includes a light source, an integrating sphere, and a detector communicating with a computer. The measurement or calculation of the characteristics is calibrated to provide accurate, absolute values. The calibration is performed by substituting a standard sample for the piece of material, the sample having a known quantity of one or more of the relevant characteristics. The quantity measured by the system of the relevant characteristic is compared to the known quantity and a calibration constant is created thereby. 44 figs.
Fujiyoshi, Tomoharu; Ikami, Takahito; Sato, Takashi; Kikukawa, Koji; Kobayashi, Masato; Ito, Hiroshi; Yamamoto, Atsushi
2016-02-19
The consequences of matrix effects in GC are a major issue of concern in pesticide residue analysis. The aim of this study was to evaluate the applicability of an analyte protectant generator in pesticide residue analysis using a GC-MS system. The technique is based on continuous introduction of ethylene glycol into the carrier gas. Ethylene glycol as an analyte protectant effectively compensated the matrix effects in agricultural product extracts. All peak intensities were increased by this technique without affecting the GC-MS performance. Calibration curves for ethylene glycol in the GC-MS system with various degrees of pollution were compared and similar response enhancements were observed. This result suggests a convenient multi-residue GC-MS method using an analyte protectant generator instead of the conventional compensation method for matrix-induced response enhancement adding the mixture of analyte protectants into both neat and sample solutions. Copyright © 2016 Elsevier B.V. All rights reserved.
Complete analog control of the carrier-envelope-phase of a high-power laser amplifier.
Feng, C; Hergott, J-F; Paul, P-M; Chen, X; Tcherbakoff, O; Comte, M; Gobert, O; Reduzzi, M; Calegari, F; Manzoni, C; Nisoli, M; Sansone, G
2013-10-21
In this work we demonstrate the development of a complete analog feedback loop for the control of the carrier-envelope phase (CEP) of a high-average power (20 W) laser operating at 10 kHz repetition rate. The proposed method combines a detection scheme working on a single-shot basis at the full-repetition-rate of the laser system with a fast actuator based either on an acousto-optic or on an electro-optic crystal. The feedback loop is used to correct the CEP fluctuations introduced by the amplification process demonstrating a CEP residual noise of 320 mrad measured on a single-shot basis. The comparison with a feedback loop operating at a lower sampling rate indicates an improvement up to 45% in the residual noise. The measurement of the CEP drift for different integration times clearly evidences the importance of the single-shot characterization of the residual CEP drift. The demonstrated scheme could be efficiently applied for systems approaching the 100 kHz repetition rate regime.
Method and apparatus for controlling the flow rate of mercury in a flow system
Grossman, Mark W.; Speer, Richard
1991-01-01
A method for increasing the mercury flow rate to a photochemical mercury enrichment utilizing an entrainment system comprises the steps of passing a carrier gas over a pool of mercury maintained at a first temperature T1, wherein the carrier gas entrains mercury vapor; passing said mercury vapor entrained carrier gas to a second temperature zone T2 having temperature less than T1 to condense said entrained mercury vapor, thereby producing a saturated Hg condition in the carrier gas; and passing said saturated Hg carrier gas to said photochemical enrichment reactor.
Gas-liquid separator and method of operation
Soloveichik, Grigorii Lev [Latham, NY; Whitt, David Brandon [Albany, NY
2009-07-14
A system for gas-liquid separation in electrolysis processes is provided. The system includes a first compartment having a liquid carrier including a first gas therein and a second compartment having the liquid carrier including a second gas therein. The system also includes a gas-liquid separator fluidically coupled to the first and second compartments for separating the liquid carrier from the first and second gases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fayolle, M.; Yamaguchi, M.; Ohto, T.
Organic magnetoresistance (OMAR) can be caused by either single carrier (bipolaron) or double carriers (electron-hole)-based mechanisms. In order to consider applications for OMAR, it is important to control the mechanism present in the device. In this paper, we report the effect of traps on OMAR resulting of disorder at the interface between the organic active layer with the hole injection layer [poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate): PEDOT:PSS]. It has been found that while the single carriers OMAR is enhanced by the presence of traps, the double carriers OMAR is totally removed in a sample with a high interface trap density. The reasons formore » these results are discussed based on the impedance spectroscopy measurements. First, the mechanism (single or double carriers) responsible of the OMAR was determined with the support of the capacitance measurement. Then, the influence of traps was discussed with the Nyquist diagrams and phase angle-frequency plots of the samples. The results suggested that with a rough interface and thus high disorder, the presence of traps enhanced the bipolaron formation. Traps also acted as recombination centers for electron-hole pairs, which prevented the double carriers OMAR in devices with a rough interface. On the other hand, with a low trap density, i.e., with a smooth surface, the single carrier OMAR decreased, and double carriers OMAR appeared. The sign of the OMAR could then be controlled by simply sweeping the bias voltage. This work demonstrated that the roughness at the interface is important for controlling OMAR and its reproducibility, and that the combination of OMAR measurement and impedance spectroscopy is helpful for clarifying the processes at the interface.« less
Novel microwave device for nondestructive electrical characterization of semiconducting layers
NASA Astrophysics Data System (ADS)
Druon, C.; Tabourier, P.; Bourzgui, N.; Wacrenier, J. M.
1990-11-01
A microwave measurement technique, using a novel cell which enables the sheet resistance (R⧠), the carrier density (n), and the mobility (μ) of epitaxial layers to be measured, is proposed. The system, controlled by a microcomputer, performs this characterization by measuring galvanomagnetic effects. The sample is only lightly pressed on the cell. The electrical contacts between the sample and the cell are capacitive. This method is thus nondestructive and requires no technological process. The data treatment necessitates knowledge of factors which are determined from a calibration procedure made only once. For the GaAs samples reported here, the accuracy is better than 5% for R⧠, 15% for μ, and 20% for n.
DOT National Transportation Integrated Search
1979-08-01
The report examines the experiences and special problems of minority trucking firms. The firms are classified as unregulated local truckers, unregulated owner-operators, and regulated interstate common carriers. Random samples are developed for minor...
Monodisperse microdroplet generation and stopping without coalescence
Beer, Neil Reginald
2015-04-21
A system for monodispersed microdroplet generation and trapping including providing a flow channel in a microchip; producing microdroplets in the flow channel, the microdroplets movable in the flow channel; providing carrier fluid in the flow channel using a pump or pressure source; controlling movement of the microdroplets in the flow channel and trapping the microdroplets in a desired location in the flow channel. The system includes a microchip; a flow channel in the microchip; a droplet maker that generates microdroplets, the droplet maker connected to the flow channel; a carrier fluid in the flow channel, the carrier fluid introduced to the flow channel by a source of carrier fluid, the source of carrier fluid including a pump or pressure source; a valve connected to the carrier fluid that controls flow of the carrier fluid and enables trapping of the microdroplets.
Monodisperse microdroplet generation and stopping without coalescence
Beer, Neil Reginald
2016-02-23
A system for monodispersed microdroplet generation and trapping including providing a flow channel in a microchip; producing microdroplets in the flow channel, the microdroplets movable in the flow channel; providing carrier fluid in the flow channel using a pump or pressure source; controlling movement of the microdroplets in the flow channel and trapping the microdroplets in a desired location in the flow channel. The system includes a microchip; a flow channel in the microchip; a droplet maker that generates microdroplets, the droplet maker connected to the flow channel; a carrier fluid in the flow channel, the carrier fluid introduced to the flow channel by a source of carrier fluid, the source of carrier fluid including a pump or pressure source; a valve connected to the carrier fluid that controls flow of the carrier fluid and enables trapping of the microdroplets.
NASA Astrophysics Data System (ADS)
Pan, Y.; Wu, D.; Angevaare, J. R.; Luigjes, H.; Frantzeskakis, E.; de Jong, N.; van Heumen, E.; Bay, T. V.; Zwartsenberg, B.; Huang, Y. K.; Snelder, M.; Brinkman, A.; Golden, M. S.; de Visser, A.
2014-12-01
In 3D topological insulators achieving a genuine bulk-insulating state is an important research topic. Recently, the material system (Bi,Sb)2(Te,Se)3 (BSTS) has been proposed as a topological insulator with high resistivity and a low carrier concentration (Ren et al 2011 Phys. Rev. B 84 165311). Here we present a study to further refine the bulk-insulating properties of BSTS. We have synthesized BSTS single crystals with compositions around x = 0.5 and y = 1.3. Resistance and Hall effect measurements show high resistivity and record low bulk carrier density for the composition Bi1.46Sb0.54Te1.7Se1.3. The analysis of the resistance measured for crystals with different thicknesses within a parallel resistor model shows that the surface contribution to the electrical transport amounts to 97% when the sample thickness is reduced to 1 μm. The magnetoconductance of exfoliated BSTS nanoflakes shows 2D weak antilocalization with α ≃ -1 as expected for transport dominated by topological surface states.
Attached shuttle payload carriers: Versatile and affordable access to space
NASA Technical Reports Server (NTRS)
1990-01-01
The shuttle has been primarily designed to be a versatile vehicle for placing a variety of scientific and technological equipment in space including very large payloads; however, since many large payloads do not fill the shuttle bay, the space and weight margins remaining after the major payloads are accommodated often can be made available to small payloads. The Goddard Space Flight Center (GSFC) has designed standardized mounting structures and other support systems, collectively called attached shuttle payload (ASP) carriers, to make this additional space available to researchers at a relatively modest cost. Other carrier systems for ASP's are operated by other NASA centers. A major feature of the ASP carriers is their ease of use in the world of the Space Shuttle. ASP carriers attempt to minimized the payload interaction with Space Transportation System (STS) operations whenever possible. Where this is not possible, the STS services used are not extensive. As a result, the interfaces between the carriers and the STS are simplified. With this near autonomy, the requirements for supporting documentation are considerably lessened and payload costs correspondingly reduced. The ASP carrier systems and their capabilities are discussed in detail. The range of available capabilities assures that an experimenter can select the simplest, most cost-effective carrier that is compatible with his or her experimental objectives. Examples of payloads which use ASP basic hardware in nonstandard ways are also described.
NASA Astrophysics Data System (ADS)
Mavlonov, Abdurashid; Richter, Steffen; von Wenckstern, Holger; Schmidt-Grund, Rüdiger; Lorenz, Michael; Grundmann, Marius
2016-11-01
We studied the doping efficiency of Al and Ga dopants in (Mg,Zn)O alloys as a function of the growth temperature and post growth annealing times. High-temperature growth results in the highest structural quality and highest electron mobility; the doping efficiency is limited by the dopant's solubility. It was investigated in detail that a low growth temperature is needed to achieve free carrier densities above the solubility limit of the dopants. Samples grown at temperatures of 300 °C and below have a free carrier density significantly above the solubility limit yielding the minimum resistivity of ρmin=4.8 ×10-4 Ω cm for Mg0.05 Zn0.95 O:Al thin films grown on glass at 300 °C . Annealing of these samples reduces the free carrier density and the absorption edge to values similar to those of samples grown at high temperatures. The saturation of the free carrier density and the optical bandgap at their high temperature growth/annealing values is explained by the thermal creation of acceptor-like compensating defects in thermodynamic equilibrium.
Li, Chengshuai; Chen, Shichao; Klemba, Michael; Zhu, Yizheng
2016-09-01
A dual-modality birefringence/phase imaging system is presented. The system features a crystal retarder that provides polarization mixing and generates two interferometric carrier waves in a single signal spectrum. The retardation and orientation of sample birefringence can then be measured simultaneously based on spectral multiplexing interferometry. Further, with the addition of a Nomarski prism, the same setup can be used for quantitative differential interference contrast (DIC) imaging. Sample phase can then be obtained with two-dimensional integration. In addition, birefringence-induced phase error can be corrected using the birefringence data. This dual-modality approach is analyzed theoretically with Jones calculus and validated experimentally with malaria-infected red blood cells. The system generates not only corrected DIC and phase images, but a birefringence map that highlights the distribution of hemozoin crystals.
NASA Astrophysics Data System (ADS)
Li, Chengshuai; Chen, Shichao; Klemba, Michael; Zhu, Yizheng
2016-09-01
A dual-modality birefringence/phase imaging system is presented. The system features a crystal retarder that provides polarization mixing and generates two interferometric carrier waves in a single signal spectrum. The retardation and orientation of sample birefringence can then be measured simultaneously based on spectral multiplexing interferometry. Further, with the addition of a Nomarski prism, the same setup can be used for quantitative differential interference contrast (DIC) imaging. Sample phase can then be obtained with two-dimensional integration. In addition, birefringence-induced phase error can be corrected using the birefringence data. This dual-modality approach is analyzed theoretically with Jones calculus and validated experimentally with malaria-infected red blood cells. The system generates not only corrected DIC and phase images, but a birefringence map that highlights the distribution of hemozoin crystals.
Interrogator system for identifying electrical circuits
Jatko, W.B.; McNeilly, D.R.
1988-04-12
A system for interrogating electrical leads to correctly ascertain the identity of equipment attached to remote ends of the leads is disclosed. The system includes a source of a carrier signal generated in a controller/receiver to be sent over the leads and an identifier unit at the equipment. The identifier is activated by command of the carrier and uses a portion of the carrier to produce a supply voltage. Each identifier is uniquely programmed for a specific piece of equipment, and causes the impedance of the circuit to be modified whereby the carrier signal is modulated according to that program. The modulation can be amplitude, frequency or phase modulation. A demodulator in the controller/receiver analyzes the modulated carrier signal, and if a verified signal is recognized displays and/or records the information. This information can be utilized in a computer system to prepare a wiring diagram of the electrical equipment attached to specific leads. Specific circuit values are given for amplitude modulation, and the system is particularly described for use with thermocouples. 6 figs.
Interrogator system for identifying electrical circuits
Jatko, William B.; McNeilly, David R.
1988-01-01
A system for interrogating electrical leads to correctly ascertain the identity of equipment attached to remote ends of the leads. The system includes a source of a carrier signal generated in a controller/receiver to be sent over the leads and an identifier unit at the equipment. The identifier is activated by command of the carrier and uses a portion of the carrier to produce a supply voltage. Each identifier is uniquely programmed for a specific piece of equipment, and causes the impedance of the circuit to be modified whereby the carrier signal is modulated according to that program. The modulation can be amplitude, frequency or phase modulation. A demodulator in the controller/receiver analyzes the modulated carrier signal, and if a verified signal is recognized displays and/or records the information. This information can be utilized in a computer system to prepare a wiring diagram of the electrical equipment attached to specific leads. Specific circuit values are given for amplitude modulation, and the system is particularly described for use with thermocouples.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perriot, Romain; Dholabhai, Pratik P.; Uberuaga, Blas P.
In this paper, we use molecular dynamics simulations to investigate the role of grain boundaries (GBs) on ionic diffusion in pyrochlores, as a function of the GB type, chemistry of the compound, and level of cation disorder. We observe that the presence of GBs promotes oxygen transport in ordered and low-disordered systems, as the GBs are found to have a higher concentration of mobile carriers with higher mobilities than in the bulk. Thus, in ordered samples, the ionic diffusion is 2D, localized along the grain boundary. When cation disorder is introduced, bulk carriers begin to contribute to the overall diffusion,more » while the GB contribution is only slightly enhanced. In highly disordered samples, the diffusive behavior at the GBs is bulk-like, and the two contributions (bulk vs. GB) can no longer be distinguished. There is thus a transition from 2D/GB dominated oxygen diffusivity to 3D/bulk dominated diffusivity versus disorder in pyrochlores. Finally, these results provide new insights into the possibility of using internal interfaces to enhance ionic conductivity in nanostructured complex oxides.« less
Cyclotron resonance in ferromagnetic InMnAs and InMnSb
NASA Astrophysics Data System (ADS)
Khodaparast, G. A.; Matsuda, Y. H.; Saha, D.; Sanders, G. D.; Stanton, C. J.; Saito, H.; Takeyama, S.; Merritt, T. R.; Feeser, C.; Wessels, B. W.; Liu, X.; Furdyna, J.
2013-12-01
We present experimental and theoretical studies of the magneto-optical properties of p-type In1-xMnxAs and In1-xMnxSb ferromagnetic semiconductor films in ultrahigh magnetic fields oriented along [001]. Samples were fabricated by molecular beam epitaxy (MBE) and metal-organic vapor phase epitaxy (MOVPE). To model the results, we used an 8-band Pidgeon-Brown model generalized to include the wave vector dependence of the elec-tronic states along kz as well as the s-d and p-d exchange interactions with the localized Mn d electrons. The Curie temperature is taken as an input parameter and the average Mn spin is treated in mean-field theory. We compared Landau level and band structure calculations with observed cyclotron resonance (CR) measurements. While differences between the CR measurements are seen for MBE and MOVPE samples, our calculations indicate that they arise from differences in the carrier densities. In addition, the difference in the carrier densities suggests significantly larger average spin for the MOVPE structures; this fact could be responsible for higher Curie temperatures in this material system.
Disorder-induced transition from grain boundary to bulk dominated ionic diffusion in pyrochlores
Perriot, Romain; Dholabhai, Pratik P.; Uberuaga, Blas P.
2017-05-04
In this paper, we use molecular dynamics simulations to investigate the role of grain boundaries (GBs) on ionic diffusion in pyrochlores, as a function of the GB type, chemistry of the compound, and level of cation disorder. We observe that the presence of GBs promotes oxygen transport in ordered and low-disordered systems, as the GBs are found to have a higher concentration of mobile carriers with higher mobilities than in the bulk. Thus, in ordered samples, the ionic diffusion is 2D, localized along the grain boundary. When cation disorder is introduced, bulk carriers begin to contribute to the overall diffusion,more » while the GB contribution is only slightly enhanced. In highly disordered samples, the diffusive behavior at the GBs is bulk-like, and the two contributions (bulk vs. GB) can no longer be distinguished. There is thus a transition from 2D/GB dominated oxygen diffusivity to 3D/bulk dominated diffusivity versus disorder in pyrochlores. Finally, these results provide new insights into the possibility of using internal interfaces to enhance ionic conductivity in nanostructured complex oxides.« less
Van Berkel, Gary J.; Kertesz, Vilmos; Orcutt, Matt; ...
2017-11-07
The aim of this work was to demonstrate and to evaluate the analytical performance of a combined falling drop/open port sampling interface (OPSI) system as a simple noncontact, no-carryover, automated system for flow injection analysis with mass spectrometry. The falling sample drops were introduced into the OPSI using a widely available autosampler platform utilizing low cost disposable pipet tips and conventional disposable microtiter well plates. The volume of the drops that fell onto the OPSI was in the 7–15 μL range with an injected sample volume of several hundred nanoliters. Sample drop height, positioning of the internal capillary on themore » sampling end of the probe, and carrier solvent flow rate were optimized for maximum signal. Sample throughput, signal reproducibility, matrix effects, and quantitative analysis capability of the system were established using the drug molecule propranolol and its isotope labeled internal standard in water, unprocessed river water and two commercially available buffer matrices. A sample-to-sample throughput of ~45 s with a ~4.5 s base-to-base flow injection peak profile was obtained in these experiments. In addition, quantitation with minimally processed rat plasma samples was demonstrated with three different statin drugs (atorvastatin, rosuvastatin, and fluvastatin). Direct characterization capability of unprocessed samples was demonstrated by the analysis of neat vegetable oils. Employing the autosampler system for spatially resolved liquid extraction surface sampling exemplified by the analysis of propranolol and its hydroxypropranolol glucuronide phase II metabolites from a rat thin tissue section was also illustrated.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Berkel, Gary J.; Kertesz, Vilmos; Orcutt, Matt
The aim of this work was to demonstrate and to evaluate the analytical performance of a combined falling drop/open port sampling interface (OPSI) system as a simple noncontact, no-carryover, automated system for flow injection analysis with mass spectrometry. The falling sample drops were introduced into the OPSI using a widely available autosampler platform utilizing low cost disposable pipet tips and conventional disposable microtiter well plates. The volume of the drops that fell onto the OPSI was in the 7–15 μL range with an injected sample volume of several hundred nanoliters. Sample drop height, positioning of the internal capillary on themore » sampling end of the probe, and carrier solvent flow rate were optimized for maximum signal. Sample throughput, signal reproducibility, matrix effects, and quantitative analysis capability of the system were established using the drug molecule propranolol and its isotope labeled internal standard in water, unprocessed river water and two commercially available buffer matrices. A sample-to-sample throughput of ~45 s with a ~4.5 s base-to-base flow injection peak profile was obtained in these experiments. In addition, quantitation with minimally processed rat plasma samples was demonstrated with three different statin drugs (atorvastatin, rosuvastatin, and fluvastatin). Direct characterization capability of unprocessed samples was demonstrated by the analysis of neat vegetable oils. Employing the autosampler system for spatially resolved liquid extraction surface sampling exemplified by the analysis of propranolol and its hydroxypropranolol glucuronide phase II metabolites from a rat thin tissue section was also illustrated.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-13
... carriers, including each carrier operating light rail or heavy rail transit service on track that is part of the general railroad system of transportation and rail transit systems. Also, these persons are... any threat information. In addition, freight railroad carriers and the affected shippers and receivers...
28 CFR 25.55 - Responsibilities of insurance carriers.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 28 Judicial Administration 1 2012-07-01 2012-07-01 false Responsibilities of insurance carriers. 25.55 Section 25.55 Judicial Administration DEPARTMENT OF JUSTICE DEPARTMENT OF JUSTICE INFORMATION SYSTEMS National Motor Vehicle Title Information System (NMVTIS) § 25.55 Responsibilities of insurance carriers. (a) By no later than March 31, 2009,...
28 CFR 25.55 - Responsibilities of insurance carriers.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 28 Judicial Administration 1 2014-07-01 2014-07-01 false Responsibilities of insurance carriers. 25.55 Section 25.55 Judicial Administration DEPARTMENT OF JUSTICE DEPARTMENT OF JUSTICE INFORMATION SYSTEMS National Motor Vehicle Title Information System (NMVTIS) § 25.55 Responsibilities of insurance carriers. (a) By no later than March 31, 2009,...
28 CFR 25.55 - Responsibilities of insurance carriers.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 28 Judicial Administration 1 2013-07-01 2013-07-01 false Responsibilities of insurance carriers. 25.55 Section 25.55 Judicial Administration DEPARTMENT OF JUSTICE DEPARTMENT OF JUSTICE INFORMATION SYSTEMS National Motor Vehicle Title Information System (NMVTIS) § 25.55 Responsibilities of insurance carriers. (a) By no later than March 31, 2009,...
Household Goods Shipments: Tender of Service for Unpacking. A Cost Savings Proposal
1991-06-01
24] Types of HHG Carriers Domes tic HHG Interstate Carriers Intrastate Carrer Carriers Agency I nd penden t Systems Var Corporate Lines Agency...range plans to change the present system. [Ref. 25] The Program Manager of Relocation for IBM indicated that they are currently looking for ways to cut
Protonic and Electronic Charge Carriers in Solvated Biomacromolecules
1989-01-01
samples with sufficient mechanical strength. The pellets were approximately one millimeter thick and were placed between two platinium foil...attached to the vacuum line, Figure 2, by simply tilting them. The platinium electrodes were blocking for protons so all protonic carriers were released
Lu, Xinqiong; Yu, Quan; Zhang, Qian; Ni, Kai; Qian, Xiang; Tang, Fei; Wang, Xiaohao
2017-08-01
A miniature ion trap mass spectrometer with capillary direct sampling and vacuum ultraviolet photoionization source was developed to conduct trace analysis of organic compounds in liquids. Self-aspiration sampling is available where the samples are drawn into the vacuum chamber through a capillary with an extremely low flow rate (less than 1 μL/min), which minimizes sample consumption in each analysis to tens of micrograms. A pulsed gas-assisted inlet was designed and optimized to promote sample transmission in the tube and facilitate the cooling of ions, thereby improving instrument sensitivity. A limit of detection of 2 ppb could be achieved for 2,4-dimethylaniline in a methanol solution. The sampling system described in the present study is specifically suitable for a miniature photoionization ion trap mass spectrometer that can perform rapid and online analysis for liquid samples. Graphical Abstract ᅟ.
NASA Astrophysics Data System (ADS)
Lu, Xinqiong; Yu, Quan; Zhang, Qian; Ni, Kai; Qian, Xiang; Tang, Fei; Wang, Xiaohao
2017-08-01
A miniature ion trap mass spectrometer with capillary direct sampling and vacuum ultraviolet photoionization source was developed to conduct trace analysis of organic compounds in liquids. Self-aspiration sampling is available where the samples are drawn into the vacuum chamber through a capillary with an extremely low flow rate (less than 1 μL/min), which minimizes sample consumption in each analysis to tens of micrograms. A pulsed gas-assisted inlet was designed and optimized to promote sample transmission in the tube and facilitate the cooling of ions, thereby improving instrument sensitivity. A limit of detection of 2 ppb could be achieved for 2,4-dimethylaniline in a methanol solution. The sampling system described in the present study is specifically suitable for a miniature photoionization ion trap mass spectrometer that can perform rapid and online analysis for liquid samples.
NASA Astrophysics Data System (ADS)
Ke, Wen-Cheng; Lee, Fang-Wei; Yang, Cheng-Yi; Chen, Wei-Kuo; Huang, Hao-Ping
2015-10-01
This study developed an Ohmic contact formation method for a ZnO:Al (AZO) transparent conductive layer on p-GaN films involving the introduction of an indium oxynitride (InON) nanodot interlayer. An antisurfactant pretreatment was used to grow InON nanodots on p-GaN films in a RF magnetron sputtering system. A low specific contact resistance of 1.12 × 10-4 Ω cm2 was achieved for a sample annealed at 500 °C for 30 s in nitrogen ambient and embedded with an InON nanodot interlayer with a nanodot density of 6.5 × 108 cm-2. By contrast, a sample annealed in oxygen ambient exhibited non-Ohmic behavior. X-ray photoemission spectroscopy results showed that the oxygen vacancy (Vo) in the InON nanodots played a crucial role in carrier transport. The fitting I-V characteristic curves indicated that the hopping mechanism with an activation energy of 31.6 meV and trap site spacing of 1.1 nm dominated the carrier transport in the AZO/InON nanodot/p-GaN sample. Because of the high density of donor-like oxygen vacancy defects at the InON nanodot/p-GaN interface, positive charges from the underlying p-GaN films were absorbed at the interface. This led to positive charge accumulation, creating a narrow depletion layer; therefore, carriers from the AZO layer passed through InON nanodots by hopping transport, and subsequently tunneling through the interface to enter the p-GaN films. Thus, AZO Ohmic contact can be formed on p-GaN films by embedding an InON nanodot interlayer to facilitate trap-assisted tunneling.
X-ray diffraction and TGA kinetic analyses for chemical looping combustion applications.
Tijani, Mansour Mohammedramadan; Aqsha, Aqsha; Mahinpey, Nader
2018-04-01
Synthesis and characterization of supported metal-based oxygen carriers were carried out to provide information related to the use of oxygen carriers for chemical looping combustion processes. The Cu, Co, Fe, Ni metals supported with Al 2 O 3 , CeO 2 , TiO 2 , ZrO 2 were prepared using the wetness impregnation technique. Then, the X-ray Diffraction (XRD) characterization of oxidized and reduced samples was obtained and presented. The kinetic analysis using Thermogravimetric analyzer (TGA) of the synthesized samples was conducted. The kinetics of reduction reaction of all samples were estimated and explained.
Soehnel, Grant
2015-01-20
The minority carrier lifetime is a measurable material property that is an indication of infrared detector device performance. To study the utility of measuring the carrier lifetime, an experiment has been constructed that can time resolve the photo-luminescent decay of a detector or wafer sample housed inside a liquid nitrogen cooled Dewar. Motorized stages allow the measurement to be scanned over the sample surface, and spatial resolutions as low as 50µm have been demonstrated. A carrier recombination simulation was developed to analyze the experimental data. Results from measurements performed on 4 mercury cadmium telluride focal plane arrays show strong correlationmore » between spatial maps of the lifetime, dark current, and relative response.« less
Evaluation of PCR Approaches for Detection of Bartonella bacilliformis in Blood Samples.
Gomes, Cláudia; Martinez-Puchol, Sandra; Pons, Maria J; Bazán, Jorge; Tinco, Carmen; del Valle, Juana; Ruiz, Joaquim
2016-03-01
The lack of an effective diagnostic tool for Carrion's disease leads to misdiagnosis, wrong treatments and perpetuation of asymptomatic carriers living in endemic areas. Conventional PCR approaches have been reported as a diagnostic technique. However, the detection limit of these techniques is not clear as well as if its usefulness in low bacteriemia cases. The aim of this study was to evaluate the detection limit of 3 PCR approaches. We determined the detection limit of 3 different PCR approaches: Bartonella-specific 16S rRNA, fla and its genes. We also evaluated the viability of dry blood spots to be used as a sample transport system. Our results show that 16S rRNA PCR is the approach with a lowest detection limit, 5 CFU/μL, and thus, the best diagnostic PCR tool studied. Dry blood spots diminish the sensitivity of the assay. From the tested PCRs, the 16S rRNA PCR-approach is the best to be used in the direct blood detection of acute cases of Carrion's disease. However its use in samples from dry blood spots results in easier management of transport samples in rural areas, a slight decrease in the sensitivity was observed. The usefulness to detect by PCR the presence of low-bacteriemic or asymptomatic carriers is doubtful, showing the need to search for new more sensible techniques.
Production of carrier-peptide conjugates using chemically reactive unnatural amino acids
Young, Travis; Schultz, Peter G
2013-12-17
Provided are methods of making carrier polypeptide that include incorporating a first unnatural amino acid into a carrier polypeptide variant, incorporating a second unnatural amino acid into a target polypeptide variant, and reacting the first and second unnatural amino acids to produce the conjugate. Conjugates produced using the provided methods are also provided. In addition, orthogonal translation systems in methylotrophic yeast and methods of using these systems to produce carrier and target polypeptide variants comprising unnatural amino acids are provided.
Production of carrier-peptide conjugates using chemically reactive unnatural amino acids
Young, Travis; Schultz, Peter G
2014-01-28
Provided are methods of making carrier polypeptide that include incorporating a first unnatural amino acid into a carrier polypeptide variant, incorporating a second unnatural amino acid into a target polypeptide variant, and reacting the first and second unnatural amino acids to produce the conjugate. Conjugates produced using the provided methods are also provided. In addition, orthogonal translation systems in methylotrophic yeast and methods of using these systems to produce carrier and target polypeptide variants comprising unnatural amino acids are provided.
Production of carrier-peptide conjugates using chemically reactive unnatural amino acids
Young, Travis; Schultz, Peter G.
2015-08-18
Provided are methods of making carrier polypeptide that include incorporating a first unnatural amino acid into a carrier polypeptide variant, incorporating a second unnatural amino acid into a target polypeptide variant, and reacting the first and second unnatural amino acids to produce the conjugate. Conjugates produced using the provided methods are also provided. In addition, orthogonal translation systems in methylotrophic yeast and methods of using these systems to produce carrier and target polypeptide variants comprising unnatural amino acids are provided.
Thermafil: A New Clinical Approach Due to New Dimensional Evaluations
Vittoria, G.; Pantaleo, G.; Blasi, A.; Spagnuolo, G.; Iandolo, A.; Amato, M.
2018-01-01
Background: There are a lot of techniques to obturate the root canals, but lateral condensation of gutta-percha is the most used one. An important aspect of thermafil is the error margin tolerated by the manufacturer in the production of plastic carriers. In literature, there is no evidence about discrepancy percentage between different carriers. It is demonstrated that the error margin of gutta-percha is 0.5% and is 0.2% for metal files (ISO standards). Objective: The aim of this study was to evaluate the real dimensions of thermafil plastic carriers observed by the stereo microscope measuring the dimensional discrepancy between them. Methods: For this study, 80 new thermafil (Dentsply Maillefer) have been selected. 40 thermafil 0.25 and 40 thermafil 0.30. Through 60X stereo microscope, the dimensions of the plastic carrier tips have been measured. The dimensions of the plastic carrier were also measured after a heating cycle. ZL GAL 11TUSM (Zetaline stereo evolution) microscope was used to observe the samples. Measurements were made through a dedicated software (Image Focus). All samples were analysed at 60X. Results: A non-parametric paired test (Wilcoxon test) was used to compare baseline and after heating values; p-values ≤ 0.05 were assumed to be statistically significant. Conclusion: The samples we measured showed a mean value of the diameters in Thermafil 25 that was 0.27 mm, for Thermafil 30 the mean value was 0.33 mm. We have measured a dimensional variable of 8% in the 25 group while in group 30 the maximum possible variation found was 4%, that’s why we propose a new protocol of obturation with thermafil. We can also conclude that a single heating process does not affect clinically the plastic carrier dimensions. PMID:29541263
Reliability issues of free-space communications systems and networks
NASA Astrophysics Data System (ADS)
Willebrand, Heinz A.
2003-04-01
Free space optics (FSO) is a high-speed point-to-point connectivity solution traditionally used in the enterprise campus networking market for building-to-building LAN connectivity. However, more recently some wire line and wireless carriers started to deploy FSO systems in their networks. The requirements on FSO system reliability, meaing both system availability and component reliability, are far more stringent in the carrier market when compared to the requirements in the enterprise market segment. This paper tries to outline some of the aspects that are important to ensure carrier class system reliability.
NASA Astrophysics Data System (ADS)
Mao, Yao; Tian, Jing; Ma, Jia-guang
2015-02-01
The techonology of LOS stabilization is widely applicated in moving carrier photoelectric systems such as shipborne, airborne and so on. In application situations with compact structure, such as LOS stabilization system of unmanned aerial vehicle, LOS stabilization based on reflector is adopted, and the detector is installed on the carrier to reduce the volume of stabilized platform and loading weight. However, the LOS deflection angle through reflector and the rotation angle of the reflector has a ratio relation of 2:1, simple reflector of stable inertial space can not make the optical axis stable. To eliminate the limitation of mirror stabilizing method, this article puts forward the carrier attitude compensation method, which uses the inertial sensor installed on the carrier to measure the attitude change of the carrier, and the stabilized platform rotating half of the carrier turbulence angle to realize the LOS stabilization.
Micoli, Francesca; Adamo, Roberto; Costantino, Paolo
2018-06-15
Currently licensed glycoconjugate vaccines are composed of a carbohydrate moiety covalently linked to a protein carrier. Polysaccharides are T-cell independent antigens able to directly stimulate B cells to produce antibodies. Disease burden caused by polysaccharide-encapsulated bacteria is highest in the first year of life, where plain polysaccharides are not generally immunogenic, limiting their use as vaccines. This limitation has been overcome by covalent coupling carbohydrate antigens to proteins that provide T cell epitopes. In addition to the protein carriers currently used in licensed glycoconjugate vaccines, there is a search for new protein carriers driven by several considerations: (i) concerns that pre-exposure or co-exposure to a given carrier can lead to immune interference and reduction of the anti-carbohydrate immune response; (ii) increasing interest to explore the dual role of proteins as carrier and protective antigen; and (iii) new ways to present carbohydrates antigens to the immune system. Protein carriers can be directly coupled to activated glycans or derivatized to introduce functional groups for subsequent conjugation. Proteins can be genetically modified to pre-determine the site of glycans attachment by insertion of unnatural amino acids bearing specific functional groups, or glycosylation consensus sequences for in vivo expression of the glycoconjugate. A large portion of the new protein carriers under investigation are recombinant ones, but more complex systems such as Outer Membrane Vesicles and other nanoparticles are being investigated. Selection criteria for new protein carriers are based on several aspects including safety, manufacturability, stability, reactivity toward conjugation, and preclinical evidence of immunogenicity of corresponding glycoconjugates. Characterization panels of protein carriers include tests before conjugation, after derivatization when applicable, and after conjugation. Glycoconjugate vaccines based on non-covalent association of carrier systems to carbohydrates are being investigated with promising results in animal models. The ability of these systems to convert T-independent carbohydrate antigens into T-dependent ones, in comparison to traditional glycoconjugates, needs to be assessed in humans.
Investigation of temperature-dependent photoluminescence in multi-quantum wells.
Fang, Yutao; Wang, Lu; Sun, Qingling; Lu, Taiping; Deng, Zhen; Ma, Ziguang; Jiang, Yang; Jia, Haiqiang; Wang, Wenxin; Zhou, Junming; Chen, Hong
2015-07-31
Photoluminescence (PL) is a nondestructive and powerful method to investigate carrier recombination and transport characteristics in semiconductor materials. In this study, the temperature dependences of photoluminescence of GaAs-AlxGa1-xAs multi-quantum wells samples with and without p-n junction were measured under both resonant and non-resonant excitation modes. An obvious increase of photoluminescence(PL) intensity as the rising of temperature in low temperature range (T < 50 K), is observed only for GaAs-AlxGa1-xAs quantum wells sample with p-n junction under non-resonant excitation. The origin of the anomalous increase of integrated PL intensity proved to be associated with the enhancement of carrier drifting because of the increase of carrier mobility in the temperature range from 15 K to 100 K. For non-resonant excitation, carriers supplied from the barriers will influence the temperature dependence of integrated PL intensity of quantum wells, which makes the traditional methods to acquire photoluminescence characters from the temperature dependence of integrated PL intensity unavailable. For resonant excitation, carriers are generated only in the wells and the temperature dependence of integrated PL intensity is very suitable to analysis the photoluminescence characters of quantum wells.
Robust Timing Synchronization in Aeronautical Mobile Communication Systems
NASA Technical Reports Server (NTRS)
Xiong, Fu-Qin; Pinchak, Stanley
2004-01-01
This work details a study of robust synchronization schemes suitable for satellite to mobile aeronautical applications. A new scheme, the Modified Sliding Window Synchronizer (MSWS), is devised and compared with existing schemes, including the traditional Early-Late Gate Synchronizer (ELGS), the Gardner Zero-Crossing Detector (GZCD), and the Sliding Window Synchronizer (SWS). Performance of the synchronization schemes is evaluated by a set of metrics that indicate performance in digital communications systems. The metrics are convergence time, mean square phase error (or root mean-square phase error), lowest SNR for locking, initial frequency offset performance, midstream frequency offset performance, and system complexity. The performance of the synchronizers is evaluated by means of Matlab simulation models. A simulation platform is devised to model the satellite to mobile aeronautical channel, consisting of a Quadrature Phase Shift Keying modulator, an additive white Gaussian noise channel, and a demodulator front end. Simulation results show that the MSWS provides the most robust performance at the cost of system complexity. The GZCD provides a good tradeoff between robustness and system complexity for communication systems that require high symbol rates or low overall system costs. The ELGS has a high system complexity despite its average performance. Overall, the SWS, originally designed for multi-carrier systems, performs very poorly in single-carrier communications systems. Table 5.1 in Section 5 provides a ranking of each of the synchronization schemes in terms of the metrics set forth in Section 4.1. Details of comparison are given in Section 5. Based on the results presented in Table 5, it is safe to say that the most robust synchronization scheme examined in this work is the high-sample-rate Modified Sliding Window Synchronizer. A close second is its low-sample-rate cousin. The tradeoff between complexity and lowest mean-square phase error determines the rankings of the Gardner Zero-Crossing Detector and both versions of the Early-Late Gate Synchronizer. The least robust models are the high and low-sample-rate Sliding Window Synchronizers. Consequently, the recommended replacement synchronizer for NASA's Advanced Air Transportation Technologies mobile aeronautical communications system is the high-sample-rate Modified Sliding Window Synchronizer. By incorporating this synchronizer into their system, NASA can be assured that their system will be operational in extremely adverse conditions. The quick convergence time of the MSWS should allow the use of high-level protocols. However, if NASA feels that reduced system complexity is the most important aspect of their replacement synchronizer, the Gardner Zero-Crossing Detector would be the best choice.
Welchko, Brian A [Torrance, CA
2012-02-14
Systems and methods are provided for pulse-width modulated control of power inverter using phase-shifted carrier signals. An electrical system comprises an energy source and a motor. The motor has a first set of windings and a second set of windings, which are electrically isolated from each other. An inverter module is coupled between the energy source and the motor and comprises a first set of phase legs coupled to the first set of windings and a second set of phase legs coupled to the second set of windings. A controller is coupled to the inverter module and is configured to achieve a desired power flow between the energy source and the motor by modulating the first set of phase legs using a first carrier signal and modulating the second set of phase legs using a second carrier signal. The second carrier signal is phase-shifted relative to the first carrier signal.
Synthetic Zeolites as Controlled-Release Delivery Systems for Anti-Inflammatory Drugs.
Khodaverdi, Elham; Soleimani, Hossein Ali; Mohammadpour, Fatemeh; Hadizadeh, Farzin
2016-06-01
Scientists have always been trying to use artificial zeolites to make modified-release drug delivery systems in the gastrointestinal tract. An ideal carrier should have the capability to release the drug in the intestine, which is the main area of absorption. Zeolites are mineral aluminosilicate compounds with regular structure and huge porosity, which are available in natural and artificial forms. In this study, soaking, filtration and solvent evaporation methods were used to load the drugs after activation of the zeolites. Weight measurement, spectroscopy FTIR, thermogravimetry and scanning electronic microscope were used to determine drug loading on the systems. Finally, consideration of drug release was made in a simulated gastric fluid and a simulated intestinal fluid for all matrixes (zeolites containing drugs) and drugs without zeolites. Diclofenac sodium (D) and piroxicam (P) were used as the drug models, and zeolites X and Y as the carriers. Drug loading percentage showed that over 90% of drugs were loaded on zeolites. Dissolution tests in stomach pH environment showed that the control samples (drug without zeolite) released considerable amount of drugs (about 90%) within first 15 min when it was about 10-20% for the matrixes. These results are favorable as NSAIDs irritate the stomach wall and it is ideal not to release much drugs in the stomach. Furthermore, release rate of drugs from matrixes has shown slower rate in comparison with control samples in intestine pH environment. © 2016 John Wiley & Sons A/S.
Chromatographic measurements of hemoglobin A2 in blood samples that contain sickle hemoglobin.
Shokrani, M; Terrell, F; Turner, E A; Aguinaga, M D
2000-04-01
In the sickle cell syndromes, Hb A2 measurements aid in the differential diagnosis of sickle cell anemia from sickle-beta-thalassemia. The purpose of this study is to assess the Hb A2 levels in samples containing sickle hemoglobin (Hb S) by the use of an automated high performance liquid chromatography system (HPLC-Variant beta-thalassemia Short Program). The blood samples analyzed were from individuals of African descent living in the state of Tennessee who had either sickle cell trait (Hb AS), sickle cell disease (Hb SS), or sickle cell-hemoglobin C disease (Hb SC). Interestingly, the Hb A2 levels determined by HPLC were found elevated in samples containing Hb S. The Hb A2 mean in Hb AS samples (n=146) is 4.09% (SD +/- 0.42, range 2.20 to 5.20%); in Hb SS samples (n=33) it is 3.90% (SD +/- 1.08, range 0.60 to 5.90%); and in Hb SC samples (n=27) it is 4.46% (SD +/- 0.70, range 2.30 to 5.91%). The Hb A2 mean by HPLC in normal individuals (Hb AA, n=70) is 2.57% (SD +/- 0.25, range 2.1 to 3.0%), and the Hb A2 range in beta-thalassemia carriers is 4 to 9%. Our results show that the Hb A2 levels in Hb S-containing samples partially overlap with those expected from beta-thalassemia carriers. The hemoglobinopathy laboratory should be aware of this apparent elevation in Hb A2 levels determined by HPLC in individuals carrying Hb S. Other factors, such as family history and clinical symptoms, should be taken into account before a diagnosis of sickle cell trait, sickle-beta-thalassemia, or sickle cell anemia is made.
Sequential injection spectrophotometric determination of oxybenzone in lipsticks.
Salvador, A; Chisvert, A; Camarasa, A; Pascual-Martí, M C; March, J G
2001-08-01
A sequential injection (SI) procedure for the spectrophotometric determination of oxybenzone in lipsticks is reported. The colorimetric reaction between nickel and oxybenzone was used. SI parameters such as sample solution volume, reagent solution volume, propulsion flow rate and reaction coil length were studied. The limit of detection was 3 microg ml(-1). The sensitivity was 0.0108+/-0.0002 ml microg(-1). The relative standard deviations of the results were between 6 and 12%. The real concentrations of samples and the values obtained by HPLC were comparable. Microwave sample pre-treatment allowed the extraction of oxybenzone with ethanol, thus avoiding the use of toxic organic solvents. Ethanol was also used as carrier in the SI system. Seventy-two injections per hour can be performed, which means a sample frequency of 24 h(-1) if three replicates are measured for each sample.
NASA Astrophysics Data System (ADS)
Zhao, Mei-Xia; Zhu, Bing-Jie
2016-04-01
Quantum dots (QDs), nano-carriers for drugs, can help realize the targeting of drugs, and improve the bioavailability of drugs in biological fields. And, a QD nano-carrier system for drugs has the potential to realize early detection, monitoring, and localized treatments of specific disease sites. In addition, QD nano-carrier systems for drugs can improve stability of drugs, lengthen circulation time in vivo, enhance targeted absorption, and improve the distribution and metabolism process of drugs in organization. So, the development of QD nano-carriers for drugs has become a hotspot in the fields of nano-drug research in recent years. In this paper, we review the advantages and applications of the QD nano-carriers for drugs in biological fields.
Tone calibration technique: A digital signaling scheme for mobile applications
NASA Technical Reports Server (NTRS)
Davarian, F.
1986-01-01
Residual carrier modulation is conventionally used in a communication link to assist the receiver with signal demodulation and detection. Although suppressed carrier modulation has a slight power advantage over the residual carrier approach in systems enjoying a high level of stability, it lacks sufficient robustness to be used in channels severely contaminated by noise, interference and propagation effects. In mobile links, in particular, the vehicle motion and multipath waveform propagation affect the received carrier in an adverse fashion. A residual carrier scheme that uses a pilot carrier to calibrate a mobile channel against multipath fading anomalies is described. The benefits of this scheme, known as tone calibration technique, are described. A brief study of the system performance in the presence of implementation anomalies is also given.
NASA Astrophysics Data System (ADS)
Beh, K. P.; Yam, F. K.; Abdalrheem, Raed; Ng, Y. Z.; Suhaimi, F. H. A.; Lim, H. S.; Mat Jafri, M. Z.
2018-04-01
In this work, graphene films were grown on copper substrates using chemical vapour deposition method under various N2 carrier flow rate. The samples were characterized using Raman spectroscopy. Three sets of Raman measurements have been performed: graphene/Cu (as-grown samples), pre-annealed graphene/glass, and post-annealed graphene/glass. It was found that the Raman spectra of graphene/Cu samples possessed a hump-shaped baseline, additionally higher signal-to-noise ratio (SNR) that leads to attenuation graphene-related bands. Significant improvement of SNR and flat baseline were observed for graphene films transferred on glass substrate. Further analysis on the remaining sets of Raman spectra highlighted minute traces of polymethyl methacrylate (PMMA) could yield misleading results. Hence, the set of Raman spectra on annealed graphene/glass samples would be suitable in further elucidating the effects of N2 carrier flow towards graphene growth. From there, higher N2 flow implied dilution of methanol/H2 mixture, limiting interactions between reactants and substrate. This leads to smaller crystallite size and lesser graphene layers.
Krug, Axel; Witt, Stephanie H; Backes, Heidelore; Dietsche, Bruno; Nieratschker, Vanessa; Shah, N Jon; Nöthen, Markus M; Rietschel, Marcella; Kircher, Tilo
2014-03-01
The alpha 1C subunit of the L-type voltage-gated calcium channel (CACNA1C) gene is one of the best replicated susceptibility loci for bipolar disorder, schizophrenia and major depression. It is involved in learning, memory and brain plasticity. Genetic studies using functional magnetic resonance imaging (fMRI) reported evidence of association with the CACNA1C single nucleotide polymorphism rs1006737 with functional correlates of episodic memory encoding and retrieval, especially activations in the hippocampus. These results, however, are inconsistent with regard to the magnitude and directionality of effect. In the present study, brain activation was measured with fMRI during an episodic memory encoding and retrieval task using neutral faces in two independent samples of 94 and 111 healthy subjects, respectively. Within whole brain analyses, a main effect of genotype emerged mainly in the right hippocampus during encoding as well as retrieval within the first sample: Carriers of the minor allele (A) exhibited lower activations compared to G/G allele carriers. This effect could be replicated within the second sample, however, only for the retrieval condition. The results strengthen findings that rs1006737 is associated with neural systems related to memory processes in hippocampal regions which are detectable in healthy subjects.
Code of Federal Regulations, 2014 CFR
2014-01-01
...) Trunk carriers; (iii) Subscriber carrier; (iv) Point-to-point radio (Microwave); (v) Coaxial cable system electronics; (vi) Fiber optic cable system electronics; (vii) Multiplex equipment; (viii) Mobile...
Code of Federal Regulations, 2013 CFR
2013-01-01
...) Trunk carriers; (iii) Subscriber carrier; (iv) Point-to-point radio (Microwave); (v) Coaxial cable system electronics; (vi) Fiber optic cable system electronics; (vii) Multiplex equipment; (viii) Mobile...
Code of Federal Regulations, 2012 CFR
2012-01-01
...) Trunk carriers; (iii) Subscriber carrier; (iv) Point-to-point radio (Microwave); (v) Coaxial cable system electronics; (vi) Fiber optic cable system electronics; (vii) Multiplex equipment; (viii) Mobile...
Wang, Shao-Ming; Hu, Shang-Ying; Chen, Wen; Chen, Feng; Zhao, Fang-Hui; He, Wei; Ma, Xin-Ming; Zhang, Yu-Qing; Wang, Jian; Sivasubramaniam, Priya; Qiao, You-Lin
2015-11-04
Liquid-state specimen carriers are inadequate for sample transportation in large-scale screening projects in low-resource settings, which necessitates the exploration of novel non-hazardous solid-state alternatives. Studies investigating the feasibility and accuracy of a solid-state human papillomavirus (HPV) sampling medium in combination with different down-stream HPV DNA assays for cervical cancer screening are needed. We collected two cervical specimens from 396 women, aged 25-65 years, who were enrolled in a cervical cancer screening trial. One sample was stored using DCM preservative solution and the other was applied to a Whatman Indicating FTA Elute® card (FTA card). All specimens were processed using three HPV testing methods, including Hybrid capture 2 (HC2), careHPV™, and Cobas®4800 tests. All the women underwent a rigorous colposcopic evaluation that included using a microbiopsy protocol. Compared to the liquid-based carrier, the FTA card demonstrated comparable sensitivity for detecting high grade Cervical Intraepithelial Neoplasia (CIN) using HC2 (91.7 %), careHPV™ (83.3 %), and Cobas®4800 (91.7 %) tests. Moreover, the FTA card showed a higher specificity compared to a liquid-based carrier for HC2 (79.5 % vs. 71.6 %, P = 0.015), comparable specificity for careHPV™ (78.1 % vs. 73.0 %, P > 0.05), but lower specificity for the Cobas®4800 test (62.4 % vs. 69.9 %, P = 0.032). Generally, the FTA card-based sampling medium's accuracy was comparable with that of liquid-based medium for the three HPV testing assays. FTA cards are a promising sample carrier for cervical cancer screening. With further optimization, it can be utilized for HPV testing in areas of varying economic development.
Saigi-Morgui, Núria; Vandenberghe, Frederik; Delacrétaz, Aurélie; Quteineh, Lina; Choong, Eva; Gholamrezaee, Mehdi; Magistretti, Pierre; Aubry, Jean-Michel; von Gunten, Armin; Preisig, Martin; Castelao, Enrique; Vollenweider, Peter; Waeber, Gerard; Kutalik, Zoltán; Conus, Philippe; Eap, Chin B
2015-10-01
Weight gain is a major health problem among psychiatric populations. It implicates several receptors and hormones involved in energy balance and metabolism. Phosphoenolpyruvate carboxykinase 1 is a rate-controlling enzyme involved in gluconeogenesis, glyceroneogenesis and cataplerosis and has been related to obesity and diabetes phenotypes in animals and humans. The aim of this study was to investigate the association of phosphoenolpyruvate carboxykinase 1 polymorphisms with metabolic traits in psychiatric patients treated with psychotropic drugs inducing weight gain and in general population samples. One polymorphism (rs11552145G > A) significantly associated with body mass index in the psychiatric discovery sample (n = 478) was replicated in 2 other psychiatric samples (n1 = 168, n2 = 188), with AA-genotype carriers having lower body mass index as compared to G-allele carriers. Stronger associations were found among women younger than 45 years carrying AA-genotype as compared to G-allele carriers (-2.25 kg/m, n = 151, P = 0.009) and in the discovery sample (-2.20 kg/m, n = 423, P = 0.0004). In the discovery sample for which metabolic parameters were available, AA-genotype showed lower waist circumference (-6.86 cm, P = 0.008) and triglycerides levels (-5.58 mg/100 mL, P < 0.002) when compared to G-allele carriers. Finally, waist-to-hip ratio was associated with rs6070157 (proxy of rs11552145, r = 0.99) in a population-based sample (N = 123,865, P = 0.022). Our results suggest an association of rs11552145G > A polymorphism with metabolic-related traits, especially in psychiatric populations and in women younger than 45 years.
Samuel, M.D.; Shadduck, D.J.; Goldberg, Diana R.; Johnson, W.P.
2005-01-01
We collected samples from apparently healthy geese in the Playa Lakes Region (USA) during the winters of 2000a??01 and 2001a??02 to determine whether carriers of Pasteurella multocida, the bacterium that causes avian cholera, were present in wild populations. With the use of methods developed in laboratory challenge trials (Samuel et al., 2003a) and a serotype-specific polymerase chain reaction method for identification of P. multocida serotype 1, we found that a small proportion of 322 wild birds (<5%) were carriers of pathogenic P. multocida. On the basis of serology, an additional group of these birds (<10%) were survivors of recent avian cholera infection. Our results confirm the hypothesis that wild waterfowl are carriers of avian cholera and add support for the hypothesis that wild birds are a reservoir for this disease. In concert with other research, this work indicates that enzootic infection with avian cholera occurs in lesser snow goose (Chen caerulescens caerulescens) populations throughout their annual cycle. Although fewer Rossa??s geese (Chen rossii) were sampled, we also found these birds were carriers of P. multocida. Even in the absence of disease outbreaks, serologic evidence indicates that chronic disease transmission and recent infection are apparently occurring year-round in these highly gregarious birds and that a small portion of these populations are potential carriers with active infection.
49 CFR 385.111 - Suspension and revocation of Mexico-domiciled carrier registration.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 5 2010-10-01 2010-10-01 false Suspension and revocation of Mexico-domiciled... SAFETY REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.111 Suspension and revocation of Mexico-domiciled carrier registration. (a) If a carrier is assigned...
DOT National Transportation Integrated Search
2017-08-01
This study estimated a significant amount of underreporting to the MCMIS crash file by the States, for the carriers who cooperated in the study. For the study carriers, it appears that the MCMIS file contained about 66 percent of their reportable cra...
49 CFR 385.111 - Suspension and revocation of Mexico-domiciled carrier registration.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 5 2014-10-01 2014-10-01 false Suspension and revocation of Mexico-domiciled... SAFETY REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.111 Suspension and revocation of Mexico-domiciled carrier registration. (a) If a carrier is assigned...
49 CFR 385.111 - Suspension and revocation of Mexico-domiciled carrier registration.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 5 2013-10-01 2013-10-01 false Suspension and revocation of Mexico-domiciled... SAFETY REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.111 Suspension and revocation of Mexico-domiciled carrier registration. (a) If a carrier is assigned...
49 CFR 385.111 - Suspension and revocation of Mexico-domiciled carrier registration.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 5 2012-10-01 2012-10-01 false Suspension and revocation of Mexico-domiciled... SAFETY REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.111 Suspension and revocation of Mexico-domiciled carrier registration. (a) If a carrier is assigned...
49 CFR 385.111 - Suspension and revocation of Mexico-domiciled carrier registration.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false Suspension and revocation of Mexico-domiciled... SAFETY REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.111 Suspension and revocation of Mexico-domiciled carrier registration. (a) If a carrier is assigned...
48 CFR 1642.1205 - Agreement to recognize carrier's change of name.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., dated , 19__, has changed its corporate name to (insert new Carrier name). (3) This amendment accomplishes a change of corporate name only and all rights and obligations of the Government and the Carrier... carrier's change of name. 1642.1205 Section 1642.1205 Federal Acquisition Regulations System OFFICE OF...
NASA Astrophysics Data System (ADS)
Sibirmovsky, Y. D.; Vasil'evskii, I. S.; Vinichenko, A. N.; Zhigunov, D. M.; Eremin, I. S.; Kolentsova, O. S.; Safonov, D. A.; Kargin, N. I.
2017-11-01
Samples of δ-Si doped AlGaAs/GaAs/AlGaAs HEMT heterostructures with GaAs quantum rings (QRs) on top of the quantum well (QW) were grown by molecular beam epitaxy and their properties were compared to the reference samples without QRs. The thickness of the QW was 6 - 10 nm for the samples with QRs and 20 nm for the reference samples. Photoluminescence measurements at low temperatures for all samples show at least two distinct lines in addition to the bulk GaAs line. The Hall effect and low temperature magnetotransport measurements at 4 - 320 K show that conductivity with and without illumination decreases significantly with QRs introduction, however the relative photoconductivity increases. Samples with 6 nm QW are insulating, which could be caused by the strong localization of the charge carriers in the QRs.
DOT National Transportation Integrated Search
2014-11-01
The research contained herein is an examination of managerial harassment experienced by drivers, and whether harassment is associated with the method used to log hours of service (HOS). Similar information was gathered from a sample of carriers. : Tr...
Hitchhiker: Customer Accommodations and Requirements Specifications (CARS)
NASA Technical Reports Server (NTRS)
1992-01-01
In 1984, NASA Headquarters established projects at the Goddard Space Flight Center (GSFC) and the Marshall Space Flight Center (MSFC) to develop quick-reaction carrier systems for low-cost 'flight of opportunity' or secondary payloads on the Space Transportation System (STS). One of these projects is the Hitchhiker (HH) Program. GSFC has developed a family of carrier equipment known as the Shuttle Payload of Opportunity Carrier (SPOC) system for mounting small payloads such as HH to the side of the Orbiter payload bay. The side-mounted HHs are referred to as Hitchhiker-G (HH-G). MSFC developed a cross-bay 'bridge-type' carrier structure called the Hitchhiker-M (HH-M). In 1987, responsibility for the HH-M carrier was transferred to and is now managed by the HH Project Office at the GSFC. The HH-M carrier now uses the same interchangeable SPOC avionics unit and the same electrical interfaces and services developed for HH-G. National Aeronautics and Space Administration (NASA) has created this document to acquaint potential HH system customers with the facilities NASA provides and the requirements which customers must satisfy to use these facilities. This publication defines interface items required for integrating customer equipment with the HH carrier system. Those items such as mounting equipment and electrical inputs and outputs; configuration, environmental, command, telemetry, and operational constraints are described as well as weight, power, and communications. The purpose of this publication is to help the customer understand essential integration documentation requirements and to prepare a Customer Payload Requirements (CPR) document.
Motawi, Tarek K; Shaker, Olfat G; Shahin, Nancy N; Ahmed, Nancy M
2016-01-01
According to the WHO report in 2015, obesity is the fifth leading cause of death worldwide, and the prevalence of Egyptian female obesity is 37.5 %. Since obesity is highly influenced by genetics, and adipose tissue renin-angiotensin system is over-activated in obesity, the effect of angiotensin-converting enzyme (ACE) insertion/deletion (I/D) polymorphism on obesity and related disorders was studied in several populations, because of its effect on ACE activity. Our objective was to study the association of ACE I/D polymorphism with obesity and certain related disorders, namely hypertension, insulin resistance and metabolic syndrome, in Egyptian females. Eighty female volunteers were recruited, blood pressure and body measurements were recorded and a fasting blood sample was obtained for the quantitation of glucose, lipid profile, insulin, leptin and identification of ACE I/D polymorphs. Subjects were grouped based on hypertension and obesity states. Comparisons of continuous parameters were made with independent sample t -test between two groups. The frequencies of ACE genotypes and alleles, and the association between gene polymorphism and metabolic parameters were assessed using chi-square or Fisher's exact test. Genotype frequencies were in Hardy-Weinberg equilibrium for all groups. Genotype distribution did not differ significantly between controls and cases of all the studied disorders. Although DD carriers had apparently higher parameters of blood pressure, lipid profile and insulin resistance, only diastolic blood pressure was almost significant ( p = 0.057). I-carriers were significantly less susceptible to hypertension than DD carriers having normal waist/hip ratio ( p = 0.007, OR = 17.29, CI = 1.81-164.96) and normal conicity index ( p = 0.024, OR = 7.00, CI = 1.36-35.93). In DD genotype carriers, a significant association was found between insulin resistance and high body mass index ( p = 0.004, OR = 8.89, CI = 1.94-40.71), waist circumference ( p = 0.003, OR = 9.63, CI = 2.14-43.36) and waist/height ratio ( p = 0.034, OR = 6.86, CI = 1.25-37.61), although the variations in percentages between DD and I-carriers were not high enough to conclude an effect of ACE I/D on such an association. In this sample of Egyptian females, ACE I/D polymorphism was not significantly associated with obesity nor with any of its related disorders studied. The I allele seemed protective against hypertension in subjects with normal, not high, waist/hip ratio and conicity index compared to DD genotype carriers.
Wang, Jian-ya; Fang, Zhao-lun
2002-02-01
A microchip flow cell was developed for flow injection renewable surface assay by reflectance spectrophotometry. The flow cell was coupled to a sequential injection system and optical fiber photometric detection system. The flow cell featured a three-layer structure. The flow channel was cut into a silicone rubber membrance which formed the middle layer, and a porous filter was inlayed across a widened section of the channel to trap microbeads introduced into the flow cell. The area of the detection window of the flow cell was approximately 3.6 mm2, the volume of the bead trapped in the flow cell was 2.2 microL, the depth of the bead layer was 600 microns. A multistrand bifurcated optical fiber was coupled with incident light, detector and flow cell. The chromogenic reaction of Cr(VI) with 1,5-diphenylcarbohydrazide (DPC) which was adsorbed on trapped Polysorb C-18 beads was used as a model reaction to optimize the flow cell design and the experimental system. The reflectance of the renewable reaction surface was monitored at 540 nm. With 100 microL sample loaded and 1.0 mL.min-1 carrier flow rate, the linear response range was 0-0.6 microgram.mL-1 Cr(VI). A detection limit (3 sigma) of 6 ng.mL-1, precision of 1.5% RSD(n = 11), and a throughput of 64 samples per hour were achieved. Considerations in system and flow cell design, the influence of depth of the bead layer, weight of beads used, and the flow rates of carrier stream on the performance were discussed.
Towards a Reduced-Wire Interface for CMUT-Based Intravascular Ultrasound Imaging Systems
Lim, Jaemyung; Tekes, Coskun; Degertekin, F. Levent; Ghovanloo, Maysam
2016-01-01
Having intravascular ultrasound (IVUS) imaging capability on guide wires used in cardiovascular interventions may eliminate the need for separate IVUS catheters and expand the use of IVUS in a larger portion of the vasculature. High frequency capacitive micro machined ultrasonic transducer (CMUT) arrays should be integrated with interface electronics and placed on the guide wire for this purpose. Besides small size, this system-on-a-chip (SoC) front-end should connect to the back-end imaging system with a minimum number of wires to preserve the critical mechanical properties of the guide wire. We present a 40 MHz CMUT array interface SoC, which will eventually use only two wires for power delivery and transmits image data using a combination of analog-to-time conversion (ATC) and an impulse radio ultra-wideband (IR-UWB) wireless link. The proof-of-concept prototype ASIC consumes only 52.8 mW and occupies 4.07 mm2 in a 0.35-μm standard CMOS process. A rectifier and regulator power the rest of the SoC at 3.3 V from a 10 MHz power carrier that is supplied through a 2.4 m micro-coax cable with an overall efficiency of 49.1%. Echo signals from an 8-element CMUT array are amplified by a transimpedance amplifier (TIA) array and down-converted to baseband by quadrature sampling using a 40 MHz clock, derived from the power carrier. The ATC generates pulse-width-modulated (PWM) samples at 2 × 10 MS/s with 6 bit resolution, while the entire system achieved 5.1 ENOB. Preliminary images from the prototype system are presented, and alternative data transmission and possible future directions towards practical implementation are discussed. PMID:27662686
Towards a Reduced-Wire Interface for CMUT-Based Intravascular Ultrasound Imaging Systems.
Lim, Jaemyung; Tekes, Coskun; Degertekin, F Levent; Ghovanloo, Maysam
2017-04-01
Having intravascular ultrasound (IVUS) imaging capability on guide wires used in cardiovascular interventions may eliminate the need for separate IVUS catheters and expand the use of IVUS in a larger portion of the vasculature. High frequency capacitive micro machined ultrasonic transducer (CMUT) arrays should be integrated with interface electronics and placed on the guide wire for this purpose. Besides small size, this system-on-a-chip (SoC) front-end should connect to the back-end imaging system with a minimum number of wires to preserve the critical mechanical properties of the guide wire. We present a 40 MHz CMUT array interface SoC, which will eventually use only two wires for power delivery and transmits image data using a combination of analog-to-time conversion (ATC) and an impulse radio ultra-wideband (IR-UWB) wireless link. The proof-of-concept prototype ASIC consumes only 52.8 mW and occupies 4.07 [Formula: see text] in a 0.35- [Formula: see text] standard CMOS process. A rectifier and regulator power the rest of the SoC at 3.3 V from a 10 MHz power carrier that is supplied through a 2.4 m micro-coax cable with an overall efficiency of 49.1%. Echo signals from an 8-element CMUT array are amplified by a transimpedance amplifier (TIA) array and down-converted to baseband by quadrature sampling using a 40 MHz clock, derived from the power carrier. The ATC generates pulse-width-modulated (PWM) samples at 2 × 10 MS/s with 6 bit resolution, while the entire system achieved 5.1 ENOB. Preliminary images from the prototype system are presented, and alternative data transmission and possible future directions towards practical implementation are discussed.
Single-cell-based system to monitor carrier driven cellular auxin homeostasis
2013-01-01
Background Abundance and distribution of the plant hormone auxin play important roles in plant development. Besides other metabolic processes, various auxin carriers control the cellular level of active auxin and, hence, are major regulators of cellular auxin homeostasis. Despite the developmental importance of auxin transporters, a simple medium-to-high throughput approach to assess carrier activities is still missing. Here we show that carrier driven depletion of cellular auxin correlates with reduced nuclear auxin signaling in tobacco Bright Yellow-2 (BY-2) cell cultures. Results We developed an easy to use transient single-cell-based system to detect carrier activity. We use the relative changes in signaling output of the auxin responsive promoter element DR5 to indirectly visualize auxin carrier activity. The feasibility of the transient approach was demonstrated by pharmacological and genetic interference with auxin signaling and transport. As a proof of concept, we provide visual evidence that the prominent auxin transport proteins PIN-FORMED (PIN)2 and PIN5 regulate cellular auxin homeostasis at the plasma membrane and endoplasmic reticulum (ER), respectively. Our data suggest that PIN2 and PIN5 have different sensitivities to the auxin transport inhibitor 1-naphthylphthalamic acid (NPA). Also the putative PIN-LIKES (PILS) auxin carrier activity at the ER is insensitive to NPA in our system, indicating that NPA blocks intercellular, but not intracellular auxin transport. Conclusions This single-cell-based system is a useful tool by which the activity of putative auxin carriers, such as PINs, PILS and WALLS ARE THIN1 (WAT1), can be indirectly visualized in a medium-to-high throughput manner. Moreover, our single cell system might be useful to investigate also other hormonal signaling pathways, such as cytokinin. PMID:23379388
Chen, Richer; Okamoto, Hirokazu; Danjo, Kazumi
2006-07-01
We prepared matrix particles of acetaminophen (Act) with chitosan (Cht) as a carrier using a newly developed 4-fluid-nozzle spray dryer. Cht dissolves in acid solutions and forms a gel, but it does not dissolve in alkaline solutions. Therefore, we tested the preparation of controlled release matrix particles using the characteristics of this carrier. Act and Cht mixtures in prescribed ratios were dissolved in an acid solution. We evaluated the matrix particles by preparing a solid dispersion using a 4-fluid-nozzle spray dryer. Observation of the particle morphology by scanning electron microscopy (SEM) revealed that the particles from the spray drying process had atomized to several microns, and that they had become spherical. We investigated the physicochemical properties of the matrix particles by powder X-ray diffraction, differential scanning calorimetry, and dissolution rate analyses with a view to clarifying the effects of crystallinity on the dissolution rate. The powder X-ray diffraction peaks and the heat of the Act fusion in the spray-dried samples decreased with the increase of the carrier content, indicating that the drug was amorphous. These results indicate that the system formed a solid dispersion. Furthermore, we investigated the interaction between the drug and carrier using FT-IR analysis. The FT-IR spectroscopy for the Act solid dispersions suggested that the Act carboxyl group and the Cht amino group formed a hydrogen bond. In addition, the measurement results of the 13C CP/MAS solid-state NMR, indicated that a hydrogen bond had been formed between the Act carbonyl group and the Cht amino group. In the Act-Cht system, the 4-fluid-nozzle spray-dried preparation with a mixing ratio of 1 : 5 obtained a sustained release preparation in all pH test solutions.
Microscopic origins of the terahertz carrier relaxation and cooling dynamics in graphene
Mihnev, Momchil T.; Kadi, Faris; Divin, Charles J.; Winzer, Torben; Lee, Seunghyun; Liu, Che-Hung; Zhong, Zhaohui; Berger, Claire; de Heer, Walt A.; Malic, Ermin; Knorr, Andreas; Norris, Theodore B.
2016-01-01
The ultrafast dynamics of hot carriers in graphene are key to both understanding of fundamental carrier–carrier interactions and carrier–phonon relaxation processes in two-dimensional materials, and understanding of the physics underlying novel high-speed electronic and optoelectronic devices. Many recent experiments on hot carriers using terahertz spectroscopy and related techniques have interpreted the variety of observed signals within phenomenological frameworks, and sometimes invoke extrinsic effects such as disorder. Here, we present an integrated experimental and theoretical programme, using ultrafast time-resolved terahertz spectroscopy combined with microscopic modelling, to systematically investigate the hot-carrier dynamics in a wide array of graphene samples having varying amounts of disorder and with either high or low doping levels. The theory reproduces the observed dynamics quantitatively without the need to invoke any fitting parameters, phenomenological models or extrinsic effects such as disorder. We demonstrate that the dynamics are dominated by the combined effect of efficient carrier–carrier scattering, which maintains a thermalized carrier distribution, and carrier–optical–phonon scattering, which removes energy from the carrier liquid. PMID:27221060
Investigation of the Best Saccharomyces cerevisiae Growth Condition.
Salari, Roshanak; Salari, Rosita
2017-01-01
Saccharomyces cerevisiae is known as one of the useful yeasts which are utilized in baking and other industries. It can be easily cultured at an economic price. Today the introduction of safe and efficient carriers is being considered. Due to its generally round shape, and the volume that is enclosed by its membrane and cell wall, it is used to encapsulate active materials to protect them from degradation or to introduce a sustained release drug delivery system. Providing the best conditions in order to achieve the best morphological properties of Saccharomyces cerevisiae as a carrier. In this research, the most suitable growth condition of yeast cells which provides the best size for use as drug carriers was found by a bioreactor in a synthetic culture medium. Yeast cell reproduction and growth curves were obtained, based on pour plate colony counting data and UV/Visible sample absorption at 600 nm. Yeast cell growth patterns and growth rates were determined by Matlab mathematical software. Results showed that pH=4 and dissolving oxygen (DO) 5% was the best condition for yeast cells to grow and reproduce. This condition also provided the largest size (2 × 3 μ) yeast cells. Owing to the yeast cells' low-cost production and their structural characteristics, they could be used as potent drug carriers. This work was supported by a grant from the Vice Chancellor of Research of Mashhad University of Medical Sciences.
Stallmann, Hein P; Faber, Chris; Bronckers, Antonius LJJ; Nieuw Amerongen, Arie V; Wuisman, Paul IJM
2006-01-01
Background Polymethyl-methacrylate (PMMA) beads releasing antibiotics are used extensively to treat osteomyelitis, but require surgical removal afterwards because they do not degrade. Methods As an alternative option, this report compares the in vitro gentamicin release profile from clinically used, biodegradable carrier-materials: six injectable cements and six granule-types. Cement cylinders and coated granules containing 3% gentamicin were submerged in dH2O and placed in a 48-sample parallel drug-release system. At regular intervals (30, 90, 180 min. and then every 24 h, for 21 days), the release fluid was exchanged and the gentamicin concentration was measured. The activity of released gentamicin was tested on Staphylococcus aureus. Results All combinations showed initial burst-release of active gentamicin, two cements had continuous-release (17 days). The relative release of all cements (36–85%) and granules (30–62%) was higher than previously reported for injectable PMMA-cements (up to 17%) and comparable to other biodegradable carriers. From the cements residual gentamicin could be extracted, whereas the granules released all gentamicin that had adhered to the surface. Conclusion The high release achieved shows great promise for clinical application of these biodegradable drug-carriers. Using the appropriate combination, the required release profile (burst or sustained) may be achieved. PMID:16504140
NASA Astrophysics Data System (ADS)
Afalla, Jessica; Ohta, Kaoru; Tokonami, Shunrou; Prieto, Elizabeth Ann; Catindig, Gerald Angelo; Cedric Gonzales, Karl; Jaculbia, Rafael; Vasquez, John Daniel; Somintac, Armando; Salvador, Arnel; Estacio, Elmer; Tani, Masahiko; Tominaga, Keisuke
2017-11-01
Two asymmetric double quantum wells of different coupling strengths (barrier widths) were grown via molecular beam epitaxy, both samples allowing tunneling. Photoluminescence was measured at 10 and 300 K to provide evidence of tunneling, barrier dependence, and structural uniformity. Carrier dynamics at room temperature was investigated by optical pump terahertz probe (OPTP) spectroscopy. Carrier population decay rates were obtained and photoconductivity spectra were analyzed using the Drude model. This work demonstrates that carrier, and possibly tunneling dynamics in asymmetric double quantum well structures may be studied at room temperature through OPTP spectroscopy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Yuanfeng; Makongo, Julien P.A.; Page, Alexander
Energy filtering of charge carriers in a semiconducting matrix using atomically coherent nanostructures can lead to a significant improvement of the thermoelectric figure of merit of the resulting composite. In this work, several half-Heusler/full-Heusler (HH/FH) nanocomposites with general compositions Zr{sub 0.25}Hf{sub 0.75}Ni{sub 1+x}Sn{sub 1−y}Sb{sub y} (0≤x≤0.15 and y=0.005, 0.01 and 0.025) were synthesized in order to investigate the behavior of extrinsic carriers at the HH/FH interfaces. Electronic transport data showed that energy filtering of carriers at the HH/FH interfaces in Zr{sub 0.25}Hf{sub 0.75}Ni{sub 1+x}Sn{sub 1−y}Sb{sub y} samples strongly depends on the doping level (y value) as well as the energymore » levels occupied by impurity states in the samples. For example, it was found that carrier filtering at HH/FH interfaces is negligible in Zr{sub 0.25}Hf{sub 0.75}Ni{sub 1+x}Sn{sub 1−y}Sb{sub y} (y=0.01 and 0.025) composites where donor states originating from Sb dopant dominate electronic conduction. However, we observed a drastic decrease in the effective carrier density upon introduction of HH/FH interfaces for the mechanically alloyed Zr{sub 0.25}Hf{sub 0.75}Ni{sub 1+x}Sn{sub 0.995}Sb{sub 0.005} samples where donor states from unintentional Fe impurities contribute the largest fraction of conduction electrons. This work demonstrates the ability to synergistically integrate the concepts of doping and energy filtering through nanostructuring for the optimization of electronic transport in semiconductors. - Graphical abstract: Electronic transport in semiconducting half-Heusler (HH) matrices containing full-Heusler (FH) nanoinclusions strongly depends on the energy distribution of impurity states within the HH matrix with respect to the magnitude of the potential energy barrier at the HH/FH interfaces. - Highlights: • Coherent nanostructures enhanced thermoelectric behavior of half-Heusler alloys. • Nanostructures act as energy filter of carriers at the HH/FH interfaces. • Carrier filtering depends on the energy levels of impurity states in the samples.« less
Influence of a strong sample solvent on analyte dispersion in chromatographic columns.
Mishra, Manoranjan; Rana, Chinar; De Wit, A; Martin, Michel
2013-07-05
In chromatographic columns, when the eluting strength of the sample solvent is larger than that of the carrier liquid, a deformation of the analyte zone occurs because its frontal part moves at a relatively high velocity due to a low retention factor in the sample solvent while the rear part of the analyte zone is more retained in the carrier liquid and hence moves at a lower velocity. The influence of this solvent strength effect on the separation of analytes is studied here theoretically using a mass balance model describing the spatio-temporal evolution of the eluent, the sample solvent and the analyte. The viscosity of the sample solvent and carrier fluid is supposed to be the same (i.e. no viscous fingering effects are taken into account). A linear isotherm adsorption with a retention factor depending upon the local concentration of the liquid phase is considered. The governing equations are numerically solved by using a Fourier spectral method and parametric studies are performed to analyze the effect of various governing parameters on the dispersion and skewness of the analyte zone. The distortion of this zone is found to depend strongly on the difference in eluting strength between the mobile phase and the sample solvent as well as on the sample volume. Copyright © 2013 Elsevier B.V. All rights reserved.
Ocular findings associated with a Cys39Arg mutation in the Norrie disease gene.
Joos, K M; Kimura, A E; Vandenburgh, K; Bartley, J A; Stone, E M
1994-12-01
To diagnose the carriers and noncarriers in a family affected with Norrie disease based on molecular analysis. Family members from three generations, including one affected patient, two obligate carriers, one carrier identified with linkage analysis, one noncarrier identified with linkage analysis, and one female family member with indeterminate carrier status, were examined clinically and electrophysiologically. Linkage analysis had previously failed to determine the carrier status of one female family member in the third generation. Blood samples were screened for mutations in the Norrie disease gene with single-strand conformation polymorphism analysis. The mutation was characterized by dideoxy-termination sequencing. Ophthalmoscopy and electroretinographic examination failed to detect the carrier state. The affected individuals and carriers in this family were found to have a transition from thymidine to cytosine in the first nucleotide of codon 39 of the Norrie disease gene, causing a cysteine-to-arginine mutation. Single-strand conformation polymorphism analysis identified a patient of indeterminate status (by linkage) to be a noncarrier of Norrie disease. Ophthalmoscopy and electroretinography could not identify carriers of this Norrie disease mutation. Single-strand conformation polymorphism analysis was more sensitive and specific than linkage analysis in identifying carriers in this family.
An Examination of the U.S. Regional Airline Policies Regarding Child Restraint Systems
NASA Technical Reports Server (NTRS)
Carstenson, Larry; Sluti, Donald; Luedtke, Jacqueline
2000-01-01
A prior study examined the policies of U.S. air carriers with regard to the use of infant restraint systems on board commercial aircraft. This study expands on that earlier study by examining the policies of commuter air carriers in the United States regarding the use of infant restraint systems. The management policy of the commuter air carriers has been investigated and officials of the commuter air carriers were surveyed to determine how the carriage of infants onboard their aircraft varied among commuter airlines. The topics investigated included seat space for infants, restraint systems for infants, and amenities for infant passengers. The results of this study have been analyzed to ascertain if any recommendations can be made to the commuter airlines regarding the carriage of infants onboard their aircraft.
NASA Astrophysics Data System (ADS)
Bai, Cheng-lin; Cheng, Zhi-hui
2016-09-01
In order to further improve the carrier synchronization estimation range and accuracy at low signal-to-noise ratio ( SNR), this paper proposes a code-aided carrier synchronization algorithm based on improved nonbinary low-density parity-check (NB-LDPC) codes to study the polarization-division-multiplexing coherent optical orthogonal frequency division multiplexing (PDM-CO-OFDM) system performance in the cases of quadrature phase shift keying (QPSK) and 16 quadrature amplitude modulation (16-QAM) modes. The simulation results indicate that this algorithm can enlarge frequency and phase offset estimation ranges and enhance accuracy of the system greatly, and the bit error rate ( BER) performance of the system is improved effectively compared with that of the system employing traditional NB-LDPC code-aided carrier synchronization algorithm.
Development of a wireless system for auditory neuroscience.
Lukes, A J; Lear, A T; Snider, R K
2001-01-01
In order to study how the auditory cortex extracts communication sounds in a realistic acoustic environment, a wireless system is being developed that will transmit acoustic as well as neural signals. The miniature transmitter will be capable of transmitting two acoustic signals with 37.5 KHz bandwidths (75 KHz sample rate) and 56 neural signals with bandwidths of 9.375 KHz (18.75 KHz sample rate). These signals will be time-division multiplexed into one high bandwidth signal with a 1.2 MHz sample rate. This high bandwidth signal will then be frequency modulated onto a 2.4 GHz carrier, which resides in the industrial, scientic, and medical (ISM) band that is designed for low-power short-range wireless applications. On the receiver side, the signal will be demodulated from the 2.4 GHz carrier and then digitized by an analog-to-digital (A/D) converter. The acoustic and neural signals will be digitally demultiplexed from the multiplexed signal into their respective channels. Oversampling (20 MHz) will allow the reconstruction of the multiplexing clock by a digital signal processor (DSP) that will perform frame and bit synchronization. A frame is a subset of the signal that contains all the channels and several channels tied high and low will signal the start of a frame. This technological development will bring two benefits to auditory neuroscience. It will allow simultaneous recording of many neurons that will permit studies of population codes. It will also allow neural functions to be determined in higher auditory areas by correlating neural and acoustic signals without apriori knowledge of the necessary stimuli.
NASA Astrophysics Data System (ADS)
Devidas, T. R.; Abhirami, S.; Sharma, Shilpam; Amaladas, E. P.; Mani, Awadhesh
2018-03-01
Studies on the electrical transport properties of the 3D topological insulators Bi2Se3 under iso-electronic substitution of Te at Se sites and the application of external pressure have been performed to understand the evolution of its ground-state properties and to explore possible electronic phase transitions in Bi2Se3‑x Te x (x=0\\text{--}3 ) systems. While the external pressure suppresses the metallic behaviour of Bi2Se3 arising from defect charge carriers leading ultimately to non-metal behaviour, the effect of pressure on Te-doped samples x=1\\text{--}2 seems to be more striking, and causes multiple electronic phase transitions such as an insulator-to-metal transition (MIT) followed by pressure-induced superconducting transition at higher pressures. All the critical parameters such as critical pressure for the occurrence of MIT (PMIT}) , superconductivity (PSC}) and maximum pressure induced superconducting transition temperature (Tc,max}) for given compositions are seen to exhibit maxima at x=1.6 which is the composition that exhibits the most insulating behaviour with least concentration of defect charge carriers among the samples of Bi2Se3‑x Te x (x=0\\text{--}3 ) series. The superconducting transition temperature (Tc}) decreases with increasing pressure in x=1\\text{--}2 samples, while it remains nearly constant for Bi2Te3. Based on the analysis of the experimental data it is surmised that the pressure-induced superconductivity seen in these systems is of conventional (BCS) type.
Fakhri, Ali; Tahami, Shiva; Nejad, Pedram Afshar
2017-10-01
The Best performance drug delivery systems designed with Fe 3 O 4 -Ag 2 O quantum dots decorated cellulose nanofibers which that grafted with Etoposide and Methotrexate. Morphology properties were characterized by Scanning and Transmittance electron microscopy. The crystalline structure of prepared sample was evaluated using by X-ray diffraction. The vibrating sample magnetometer analysis was used for magnetic behavior of samples. The size distributions of Fe 3 O 4 -Ag 2 O QDs/Cellulose fibers nanocomposites indicate that the average diameter was 62.5nm. The Saturation magnetization (Ms) indicates the Fe 3 O 4 -Ag 2 O QDs/Cellulose fibers nanocomposites have ferromagnetic properties in nature. For make carrier, the Iron and Silver should be binds to cellulose nanofibers and to drug molecules and observe in UV-vis spectroscopy. The drug release kinetics was studied in vitro as spectrophotometrically. The release of Etoposide and Methotrexate were carried out with a constant speed, and the equilibrium reached at 24 and 30h with a total amount 78.94% and 63.84%, respectively. The results demonstrated that the obtained Fe 3 O 4 -Ag 2 O quantum dots/cellulose fibers nanocomposites could be applied for drug delivery systems. Cytotoxicity and antioxidant study confirmed the activity of the drug incorporated in nanocomposites. In addition, the cytotoxicity of drug was increased when loaded on nanocomposites, compared to pure Fe 3 O 4 -Ag 2 O quantum dots/cellulose fibers nanocomposites. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Pastor, David; Gandhi, Hemi H.; Monmeyran, Corentin P.; Akey, Austin J.; Milazzo, Ruggero; Cai, Yan; Napolitani, Enrico; Gwilliam, Russell M.; Crowe, Iain F.; Michel, Jurgen; Kimerling, L. C.; Agarwal, Anuradha; Mazur, Eric; Aziz, Michael J.
2018-04-01
Obtaining high level active n+ carrier concentrations in germanium (Ge) has been a significant challenge for further development of Ge devices. By ion implanting phosphorus (P) and fluorine (F) into Ge and restoring crystallinity using Nd:YAG nanosecond pulsed laser melting (PLM), we demonstrate 1020 cm-3 n+ carrier concentration in tensile-strained epitaxial germanium-on-silicon. Scanning electron microscopy shows that after laser treatment, samples implanted with P have an ablated surface, whereas P + F co-implanted samples have good crystallinity and a smooth surface topography. We characterize P and F concentration depth profiles using secondary ion mass spectrometry and spreading resistance profiling. The peak carrier concentration, 1020 cm-3 at 80 nm below the surface, coincides with the peak F concentration, illustrating the key role of F in increasing donor activation. Cross-sectional transmission electron microscopy of the co-implanted sample shows that the Ge epilayer region damaged during implantation is a single crystal after PLM. High-resolution X-ray diffraction and Raman spectroscopy measurements both indicate that the as-grown epitaxial layer strain is preserved after PLM. These results demonstrate that co-implantation and PLM can achieve the combination of n+ carrier concentration and strain in Ge epilayers necessary for next-generation, high-performance Ge-on-Si devices.
Electrical conductivity of high-purity germanium crystals at low temperature
NASA Astrophysics Data System (ADS)
Yang, Gang; Kooi, Kyler; Wang, Guojian; Mei, Hao; Li, Yangyang; Mei, Dongming
2018-05-01
The temperature dependence of electrical conductivity of single-crystal and polycrystalline high-purity germanium (HPGe) samples has been investigated in the temperature range from 7 to 100 K. The conductivity versus inverse of temperature curves for three single-crystal samples consist of two distinct temperature ranges: a high-temperature range where the conductivity increases to a maximum with decreasing temperature, and a low-temperature range where the conductivity continues decreasing slowly with decreasing temperature. In contrast, the conductivity versus inverse of temperature curves for three polycrystalline samples, in addition to a high- and a low-temperature range where a similar conductive behavior is shown, have a medium-temperature range where the conductivity decreases dramatically with decreasing temperature. The turning point temperature ({Tm}) which corresponds to the maximum values of the conductivity on the conductivity versus inverse of temperature curves are higher for the polycrystalline samples than for the single-crystal samples. Additionally, the net carrier concentrations of all samples have been calculated based on measured conductivity in the whole measurement temperature range. The calculated results show that the ionized carrier concentration increases with increasing temperature due to thermal excitation, but it reaches saturation around 40 K for the single-crystal samples and 70 K for the polycrystalline samples. All these differences between the single-crystal samples and the polycrystalline samples could be attributed to trapping and scattering effects of the grain boundaries on the charge carriers. The relevant physical models have been proposed to explain these differences in the conductive behaviors between two kinds of samples.
Parthiban, Aravindh Babu R; Mahapatra, Mana; Gubbins, Simon; Parida, Satya
2015-01-01
The role of foot-and-mouth disease virus (FMDV) carrier cattle in causing new outbreaks is still a matter of debate and it is important to find out these carrier animals by post-outbreak serosurveillance to declare freedom from FMDV infection. In this study we explore the differences in viral shedding between carrier and non-carrier animals, quantify the transmission rate of FMDV infection from carriers to susceptible animals and identify potential viral determinants of viral persistence. We collected nasal and saliva samples from 32 vaccinated and 7 unvaccinated FMDV carrier cattle and 48 vaccinated and 13 unvaccinated non-carrier cattle (total n=100) during the acute phase of infection (up to 28 days post-challenge) and then from limited number of animals up to a maximum 168 days post-challenge. We demonstrate that unvaccinated cattle excrete significantly higher levels of virus for longer periods compared with vaccinated cattle and this is independent of whether or not they subsequently become carriers. By introducing naïve cattle in to the FMDV carrier population we show the risk of new outbreaks is clearly very low in controlled conditions, although there could still be a potential threat of these carrier animals causing new outbreaks in the field situation. Finally, we compared the complete genome sequences of viruses from carrier cattle with the challenge virus and found no evidence for viral determinants of the carrier state.
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : second quarter : [2008
DOT National Transportation Integrated Search
2008-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : fourth quarter : [2013
DOT National Transportation Integrated Search
2013-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : second quarter : [2013
DOT National Transportation Integrated Search
2013-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : first quarter : [2009
DOT National Transportation Integrated Search
2009-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : fourth quarter : [2008
DOT National Transportation Integrated Search
2008-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : second quarter : [2010
DOT National Transportation Integrated Search
2010-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : fourth quarter : [2009
DOT National Transportation Integrated Search
2009-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : second quarter : [2011
DOT National Transportation Integrated Search
2011-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : third quarter : [2011
DOT National Transportation Integrated Search
2011-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : first quarter : [2014
DOT National Transportation Integrated Search
2014-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : first quarter : [2012
DOT National Transportation Integrated Search
2012-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : second quarter : [2012
DOT National Transportation Integrated Search
2012-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : fourth quarter : [2010
DOT National Transportation Integrated Search
2010-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : third quarter : [2009
DOT National Transportation Integrated Search
2009-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : first quarter : [2011
DOT National Transportation Integrated Search
2011-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : first quarter : [2013
DOT National Transportation Integrated Search
2013-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : fourth quarter : [2011
DOT National Transportation Integrated Search
2011-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : third quarter : [2010
DOT National Transportation Integrated Search
2010-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : first quarter : [2010
DOT National Transportation Integrated Search
2010-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : third quarter : [2013
DOT National Transportation Integrated Search
2013-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : fourth quarter : [2012
DOT National Transportation Integrated Search
2012-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : second quarter : [2009
DOT National Transportation Integrated Search
2009-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : third quarter : [2012
DOT National Transportation Integrated Search
2012-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Wang, Shao-Ming; Hu, Shang-Ying; Chen, Feng; Chen, Wen; Zhao, Fang-Hui; Zhang, Yu-Qing; Ma, Xin-Ming; Qiao, You-Lin
2014-01-01
To make the clinical evaluation of a solid-state human papillomavirus (HPV) sampling medium in combination with an economical HPV testing method (careHPV™) for cervical cancer screening. 396 women aged 25-65 years were enrolled for cervical cancer screening, and four samples were collected. Two samples were collected by woman themselves, among which one was stored in DCM preservative solution (called "liquid sample") and the other was applied on the Whatman Indicating FTA Elute® card (FTA card). Another two samples were collected by physician and stored in DCM preservative solution and FTA card, respectively. All the samples were detected by careHPV™ test. All the women were administered a colposcopy examination, and biopsies were taken for pathological confirmation if necessary. FTA card demonstrated a comparable sensitivity of detecting high grade Cervical Intraepithelial Neoplasia (CIN) with the liquid sample carrier for self and physician-sampling, but showed a higher specificity than that of liquid sample carrier for self-sampling (FTA vs Liquid: 79.0% vs 71.6%, p=0.02). Generally, the FTA card had a comparable accuracy with that of Liquid-based medium by different sampling operators, with an area under the curve of 0.807 for physician and FTA, 0.781 for physician and Liquid, 0.728 for self and FTA, and 0.733 for self and Liquid (p>0.05). FTA card is a promising sample carrier for cervical cancer screening. With appropriate education programmes and further optimization of the experimental workflow, FTA card based self-collection in combination with centralized careHPV™ testing can help expand the coverage of cervical cancer screening in low-resource areas.
Biomimetics in drug delivery systems: A critical review.
Sheikhpour, Mojgan; Barani, Leila; Kasaeian, Alibakhsh
2017-05-10
Today, the advanced drug delivery systems have been focused on targeted drug delivery fields. The novel drug delivery is involved with the improvement of the capacity of drug loading in drug carriers, cellular uptake of drug carriers, and the sustained release of drugs within target cells. In this review, six groups of therapeutic drug carriers including biomimetic hydrogels, biomimetic micelles, biomimetic liposomes, biomimetic dendrimers, biomimetic polymeric carriers and biomimetic nanostructures, are studied. The subject takes advantage of the biomimetic methods of productions or the biomimetic techniques for the surface modifications, similar to what accrues in natural cells. Moreover, the effects of these biomimetic approaches for promoting the drug efficiency in targeted drug delivery are visible. The study demonstrates that the fabrication of biomimetic nanocomposite drug carriers could noticeably promote the efficiency of drugs in targeted drug delivery systems. Copyright © 2017 Elsevier B.V. All rights reserved.
Functional Properties of the Mitochondrial Carrier System.
Taylor, Eric B
2017-09-01
The mitochondrial carrier system (MCS) transports small molecules between mitochondria and the cytoplasm. It is integral to the core mitochondrial function to regulate cellular chemistry by metabolism. The mammalian MCS comprises the transporters of the 53-member canonical SLC25A family and a lesser number of identified noncanonical transporters. The recent discovery and investigations of the mitochondrial pyruvate carrier (MPC) illustrate the diverse effects a single mitochondrial carrier may exert on cellular function. However, the transport selectivities of many carriers remain unknown, and most have not been functionally investigated in mammalian cells. The mechanisms coordinating their function as a unified system remain undefined. Increased accessibility to molecular genetic and metabolomic technologies now greatly enables investigation of the MCS. Continued investigation of the MCS may reveal how mitochondria encode complex regulatory information within chemical thermodynamic gradients. This understanding may enable precision modulation of cellular chemistry to counteract the dysmetabolism inherent in disease. Copyright © 2017 Elsevier Ltd. All rights reserved.
Assessment of GPS carrier-phase stability for time-transfer applications.
Larson, K M; Levine, J; Nelson, L M; Parker, T E
2000-01-01
We have conducted global positioning system (GPS) carrier-phase time-transfer experiments between the master clock (MC) at the U.S. Naval Observatory (USNO) in Washington, DC and the alternate master clock (AMC) at Schriever Air Force Base near Colorado Springs, Colorado. These clocks are also monitored on an hourly basis with two-way satellite time-transfer (TWSTT) measurements. We compared the performance of the GPS carrier phase and TWSTT systems over a 236-d period. Because of power problems and data outages during the carrier-phase experiment, the longest continuous time span is 96 d. The data from this period show agreement with TWSTT within +/-1 ns, apart from an overall constant time offset (caused by unknown delays in the GPS hardware at both ends). For averaging times of a day, the carrier-phase and TWSTT systems have a frequency uncertainty of 2.5 and 5.5 parts in 10(15), respectively.
48 CFR 47.303-10 - F.o.b. inland carrier, point of exportation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false F.o.b. inland carrier... ACQUISITION REGULATION CONTRACT MANAGEMENT TRANSPORTATION Transportation in Supply Contracts 47.303-10 F.o.b. inland carrier, point of exportation. (a) Explanation of delivery term. F.o.b. inland carrier, point of...
48 CFR 1642.1205 - Agreement to recognize carrier's change of name.
Code of Federal Regulations, 2013 CFR
2013-10-01
... incorporation, dated , 19__, has changed its corporate name to (insert new Carrier name). (3) This amendment accomplishes a change of corporate name only and all rights and obligations of the Government and the Carrier... carrier's change of name. 1642.1205 Section 1642.1205 Federal Acquisition Regulations System OFFICE OF...
48 CFR 1642.1205 - Agreement to recognize carrier's change of name.
Code of Federal Regulations, 2014 CFR
2014-10-01
... incorporation, dated , 19__, has changed its corporate name to (insert new Carrier name). (3) This amendment accomplishes a change of corporate name only and all rights and obligations of the Government and the Carrier... carrier's change of name. 1642.1205 Section 1642.1205 Federal Acquisition Regulations System OFFICE OF...
Universal multiplex PCR and CE for quantification of SMN1/SMN2 genes in spinal muscular atrophy.
Wang, Chun-Chi; Chang, Jan-Gowth; Jong, Yuh-Jyh; Wu, Shou-Mei
2009-04-01
We established a universal multiplex PCR and CE to calculate the copy number of survival motor neuron (SMN1 and SMN2) genes for clinical screening of spinal muscular atrophy (SMA). In this study, one universal fluorescent primer was designed and applied for multiplex PCR of SMN1, SMN2 and two internal standards (CYBB and KRIT1). These amplicons were separated by conformation sensitive CE. Mixture of hydroxyethyl cellulose and hydroxypropyl cellulose were used in this CE system. Our method provided the potential to separate two 390-bp PCR products that differ in a single nucleotide. Differentiation and quantification of SMN1 and SMN2 are essential for clinical screening of SMA patients and carriers. The DNA samples included 22 SMA patients, 45 parents of SMA patients (obligatory carriers) and 217 controls. For evaluating accuracy, those 284 samples were blind-analyzed by this method and denaturing high pressure liquid chromatography (DHPLC). Eight of the total samples showed different results. Among them, two samples were diagnosed as having only SMN2 gene by DHPLC, however, they contained both SMN1 and SMN2 by our method. They were further confirmed by DNA sequencing. Our method showed good agreement with the DNA sequencing. The multiplex ligation-dependent probe amplification (MLPA) was used for confirming the other five samples, and showed the same results with our CE method. For only one sample, our CE showed different results with MLPA and DNA sequencing. One out of 284 samples (0.35%) belonged to mismatching. Our method provided a better accurate method and convenient method for clinical genotyping of SMA disease.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Falkenbach, Oliver; Koch, Guenter; Schlecht, Sabine
2016-06-07
We report on the preparation and thermoelectric properties of the quaternary system AgPb{sub m}BiTe{sub 2+m} (Bismuth-Lead-Silver-Tellurium, BLST-m) that were nanostructured by mechanical alloying. Nanopowders of various compositions were compacted by three different methods: cold pressing/annealing, hot pressing, and short term sintering. The products are compared with respect to microstructure and sample density. The thermoelectric properties were measured: thermal conductivity in the temperature range from 300 K to 800 K and electrical conductivity and Seebeck coefficient between 100 K and 800 K. The compacting method and the composition had a substantial impact on carrier concentration and mobility as well as on the thermoelectric parameters. Roommore » temperature Hall measurements yielded carrier concentrations in the order of 10{sup 19 }cm{sup −3}, slightly increasing with increasing content of the additive silver bismuth telluride to the lead telluride base. ZT values close to the ones of bulk samples were achieved. X-ray diffraction and transmission electron microscopy (TEM) showed macroscopically homogeneous distributions of the constituting elements inside the nanopowders ensembles, indicating a solid solution. However, high resolution transmission electron microscopy (HRTEM) revealed disorder on the nanoscale inside individual nanopowders grains.« less
NASA Astrophysics Data System (ADS)
Bhowmik, R. N.; Siva, K. Venkata
2018-07-01
The samples of Ga-doped Cr2O3 system in rhombohedral crystal structure with space group R 3 bar C were prepared by chemical co-precipitation route and annealing at 800 °C. The current-voltage (I-V) curves exhibited many unique non-linear properties, e.g., hysteresis loop, resistive switching, and negative differential resistance (NDR). In this work, we report non-equilibrium properties of resistive switching and NDR phenomena. The non-equilibrium I-V characteristics were confirmed by repetiting measurement and time relaxation of current. The charge conduction process was understood by analysing the I-V curves using electrode-limited and bulk-limited charge conduction mechanisms, which were proposed for metal electrode/metal oxide/metal electrode structure. The I-V curves in the NDR regime and at higher bias voltage regime in our samples did not obey Fowler-Nordheim equation, which was proposed for charge tunneling mechanism in many thin film junctions. The non-equilibrium I-V phenomena were explained by considering the competitions between the injection of charge carriers from metal electrode to metal oxide, the charge flow through bulk material mediated by trapping/de-trapping and recombination of charge carriers at the defect sites of ions, the space charge effects at the junctions of electrodes and metal oxides, and finally, the out flow of electrons from metal oxide to metal electrode.
Optical Properties of a Quantum Dot-Ring System Grown Using Droplet Epitaxy.
Linares-García, Gabriel; Meza-Montes, Lilia; Stinaff, Eric; Alsolamy, S M; Ware, M E; Mazur, Y I; Wang, Z M; Lee, Jihoon; Salamo, G J
2016-12-01
Electronic and optical properties of InAs/GaAs nanostructures grown by the droplet epitaxy method are studied. Carrier states were determined by k · p theory including effects of strain and In gradient concentration for a model geometry. Wavefunctions are highly localized in the dots. Coulomb and exchange interactions are studied and we found the system is in the strong confinement regime. Microphotoluminescence spectra and lifetimes were calculated and compared with measurements performed on a set of quantum rings in a single sample. Some features of spectra are in good agreement.
Quantitative polarized light microscopy using spectral multiplexing interferometry.
Li, Chengshuai; Zhu, Yizheng
2015-06-01
We propose an interferometric spectral multiplexing method for measuring birefringent specimens with simple configuration and high sensitivity. The retardation and orientation of sample birefringence are simultaneously encoded onto two spectral carrier waves, generated interferometrically by a birefringent crystal through polarization mixing. A single interference spectrum hence contains sufficient information for birefringence determination, eliminating the need for mechanical rotation or electrical modulation. The technique is analyzed theoretically and validated experimentally on cellulose film. System simplicity permits the possibility of mitigating system birefringence background. Further analysis demonstrates the technique's exquisite sensitivity as high as ∼20 pm for retardation measurement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Jingbo; Mayorov, Alexander S.; Wood, Christopher D.
2016-02-29
We have investigated terahertz (THz) frequency magnetoplasmon resonances in a two-dimensional electron system through the direct injection of picosecond duration current pulses. The evolution of the time-domain signals was measured as a function of magnetic field, and the results were found to be in agreement with calculations using a mode-matching approach for four modes observed in the frequency range above 0.1 THz. This introduces a generic technique suitable for sampling ultrafast carrier dynamics in low-dimensional semiconductor nanostructures at THz frequencies.
Research and Applications Modules (RAM). Phase B study: Executive summary
NASA Technical Reports Server (NTRS)
1972-01-01
The design, development, and characteristics of the Research and Applications Module (RAM) system is discussed. The RAM system is a family of payload carriers that can be delivered to and retrieved from low earth orbit by the space shuttle. The RAM payload carriers are used to support diverse technological and scientific investigations. The NASA study objectives, the relationship of the RAM payload carriers to other systems in the orbital space program, and recommendations for additional effort are presented.
2010-11-10
1 A bovine hemoglobin-based oxygen carrier as pump prime for cardiopulmonary bypass: reduced systemic lactic acidosis and improved cerebral...2010 2. REPORT TYPE Final Report 3. DATES COVERED (From - To) June 2007 - November 2010 4. TITLE AND SUBTITLE A bovine hemoglobin-based oxygen...carrier as pump prime for cardiopulmonary bypass: reduced systemic lactic acidosis and improved cerebral oxygen metabolism during low-flow in a
Zhang, Lijia; Liu, Bo; Xin, Xiangjun
2015-06-15
A secure optical generalized filter bank multi-carrier (GFBMC) system with carrier-less amplitude-phase (CAP) modulation is proposed in this Letter. The security is realized through cubic constellation-masked method. Large key space and more flexibility masking can be obtained by cubic constellation masking aligning with the filter bank. An experiment of 18 Gb/s encrypted GFBMC/CAP system with 25-km single-mode fiber transmission is performed to demonstrate the feasibility of the proposed method.
Motor carrier technology - fleet operational impacts and implications for ITS/CVO
DOT National Transportation Integrated Search
2000-03-01
The Intelligent Transportation Systems/Commercial Vehicle Operations (ITS/CVO) Program is a cooperative effort between the Federal Motor Carrier Safety Administration (FMSCA), the Federal Highway Administration, States, Motor carriers, and other tran...
49 CFR 1546.209 - Use of X-ray systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 9 2012-10-01 2012-10-01 false Use of X-ray systems. 1546.209 Section 1546.209... Use of X-ray systems. (a) TSA authorization required. No foreign air carrier may use any X-ray system... security program. TSA authorizes foreign air carriers to use X-ray systems for inspecting accessible...
75 FR 18255 - Passenger Facility Charge Database System for Air Carrier Reporting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-09
... Facility Charge Database System for Air Carrier Reporting AGENCY: Federal Aviation Administration (FAA... the Passenger Facility Charge (PFC) database system to report PFC quarterly report information. In... developed a national PFC database system in order to more easily track the PFC program on a nationwide basis...
49 CFR 385.715 - Duration of safety monitoring system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false Duration of safety monitoring system. 385.715... SAFETY FITNESS PROCEDURES Safety Monitoring System for Non-North American Carriers § 385.715 Duration of safety monitoring system. (a) Each non-North America-domiciled carrier subject to this subpart will...
49 CFR 385.117 - Duration of safety monitoring system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 5 2010-10-01 2010-10-01 false Duration of safety monitoring system. 385.117... SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.117 Duration of safety monitoring system. (a) Each Mexico-domiciled carrier subject to this subpart will remain in the...
49 CFR 385.117 - Duration of safety monitoring system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false Duration of safety monitoring system. 385.117... SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.117 Duration of safety monitoring system. (a) Each Mexico-domiciled carrier subject to this subpart will remain in the...
49 CFR 385.715 - Duration of safety monitoring system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 5 2010-10-01 2010-10-01 false Duration of safety monitoring system. 385.715... SAFETY FITNESS PROCEDURES Safety Monitoring System for Non-North American Carriers § 385.715 Duration of safety monitoring system. (a) Each non-North America-domiciled carrier subject to this subpart will...
40 CFR 141.802 - Coliform sampling plan.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 23 2011-07-01 2011-07-01 false Coliform sampling plan. 141.802... sampling plan. (a) Each air carrier under this subpart must develop a coliform sampling plan covering each... required actions, including repeat and follow-up sampling, corrective action, and notification of...
40 CFR 141.802 - Coliform sampling plan.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Coliform sampling plan. 141.802... sampling plan. (a) Each air carrier under this subpart must develop a coliform sampling plan covering each... required actions, including repeat and follow-up sampling, corrective action, and notification of...
Engineering antiphagocytic biomimetic drug carriers
Sawdon, Alicia; Peng, Ching-An
2014-01-01
Drug-delivery carriers have the potential to not only treat but also diagnose many diseases; however, they still lack the complexity of natural-particulate systems. Cell-based therapies using tumor-targeting T cells and tumor-homing mesenchymal stem cells have given researchers a means to exploit the characteristics exhibited by innate-biological entities. Similarly, immune evasion by pathogens has inspired the development of natural polymers to cloak drug carriers. The ‘marker-of-self’ CD47 protein, which is found ubiquitously on mammalian cell surfaces, has been used for evading phagocyte clearance of drug carriers. This review will focus on the recent progress of drug carriers co-opting the tricks that cells in nature use to hide safely under the radar of the body’s innate immune system. PMID:23883126
Jain, Shashank; Patel, Niketkumar; Shah, Mansi K; Khatri, Pinak; Vora, Namrata
2017-02-01
In the recent decade, skin delivery (topical and transdermal) has gained an unprecedented popularity, especially due to increased incidences of chronic skin diseases, demand for targeted and patient compliant delivery, and interest in life cycle management strategies among pharmaceutical companies. Literature review of recent publications indicates that among various skin delivery systems, lipid-based delivery systems (vesicular carriers and lipid particulate systems) have been the most successful. Vesicular carriers consist of liposomes, ultradeformable liposomes, and ethosomes, while lipid particulate systems consist of lipospheres, solid lipid nanoparticles, and nanostructured lipid carriers. These systems can increase the skin drug transport by improving drug solubilization in the formulation, drug partitioning into the skin, and fluidizing skin lipids. Considering that lipid-based delivery systems are regarded as safe and efficient, they are proving to be an attractive delivery strategy for the pharmaceutical as well as cosmeceutical drug substances. However, development of these delivery systems requires comprehensive understanding of physicochemical characteristics of drug and delivery carriers, formulation and process variables, mechanism of skin delivery, recent technological advancements, specific limitations, and regulatory considerations. Therefore, this review article encompasses recent research advances addressing the aforementioned issues. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
2016 pocket guide to large truck and bus statistics.
DOT National Transportation Integrated Search
2016-05-01
FMCSA created and maintains the Motor Carrier Management Information System (MCMIS). MCMIS contains information on the safety performance of commercial motor carriers (large trucks and buses) and hazardous materials (HM) carriers subject to the Feder...
2017 Pocket Guide to Large Truck and Bus Statistics.
DOT National Transportation Integrated Search
2017-06-01
FMCSA created and maintains the Motor Carrier Management Information System (MCMIS). MCMIS contains information on the safety performance of commercial motor carriers (large trucks and buses) and hazardous materials (HM) carriers subject to the Feder...
Dilogo, Ismail H; Arya, Abikara; Phedy; Loho, Tony
2013-07-01
to determine the rate of MRSA-carrier among patients, family members and health care providers, and the association between MRSA-carrier family members and health care providers on MRSA infection patient after orthopaedic surgery. this is a cross-sectional analytical study. Samples were taken consecutively during December 2010 to December 2011, consisting of postoperative patients infected with MRSA, attending family members, and the medical officers with history of contact with the patient. Swab culture were taken from nasal and axilla of all subjects. The incidence of MRSA infection, and MRSA-carrier on the patient, family members and medical officers were presented descriptively, while their association with MRSA infection was statistically tested using Fischer exact test. during the study period, there were 759 surgeries, with 4 (0.5%) patients were identified to have MRSA infection. Of these four cases, 48 subjects were enrolled. The rate of MRSA-carrier among patients, family and health care providers were 50%, 25% and 0% respectively. There were no significant association between MRSA and the rates of MRSA-carrier on the family member or health care providers. the incidence of MRSA infection, MRSA-carrier patient, MRSA-carrier health care providers, and family member carrier were 0.5%, 50%, 0%, and 25% respectively. No significant association found between MRSA-carrier on the family member or health care providers and MRSA infection patient. There were no MRSA infection found on the health care provider.
A new technology for harnessing the dye polluted water and dye collection in a chemical factory.
Pu, J P; Pu, P M; Hu, C H; Qian, J L; Pu, J X; Hua, J K
2001-04-01
A new technology for harnessing the dye polluted water and dye collection was developed. It is based on the enhanced evaporation by using solar, wind and air temperature energy and additional heat-electric energy. It consists of four parts: (1) evaporation carrier system (evaporation carrier and frame for evaporation carrier) for polluted water; (2) polluted water circulating system (pumping-spraying-collecting); (3) heating system; (4) workshop with polluted water reservoir-tanks and rainfall prevention roof. The polluted water was (heated in case necessary) sprayed to the evaporation carrier system and the water was evaporated when it moved in the space and downward along the carrier mainly by using natural (solar, wind and air temperature energy). In case, when there is no roof for the carrier system, the polluted water can be stored in the reservoirs (storage volume for about 20 days). The first 10-25 mm rainfall also need to be stored in the reservoirs to meet the state standard for discharging wastewater. The dye may be collected at the surface in the reservoir-tanks and the crystallized salt may be collected at the bottom plate. The black-color wastewater released by the factory is no more discharged to the surface water system of Taihu Lake Basin. About 2 kg dye and 200 kg industrial salt may be collected from each tone of the polluted water. The non-pollution production of dye may be realized by using this technology with environmental, economical and social benefits.
Buntić, Aneta V; Pavlović, Marija D; Antonović, Dušan G; Šiler-Marinković, Slavica S; Dimitrijević-Branković, Suzana I
2016-08-01
This study has explored the feasibility of using spent coffee grounds as a good supporting material for the Paenibacillus chitinolyticus CKS1 cellulase immobilization. An optimal operational conditions in a batch-adsorption system were found to be: carrier mass of 12 g/L, under the temperature of 45 °C and no pH adjustments. The immobilization yield reached about 71%. An equilibrium establishment between the cellulase and the carrier surface occurred within 45 min, whereas the process kinetics may be predicted by the pseudo-second-order model. An immobilized cellulase preparation expressed very good avicelase activity, this reached up to 2.67 U/g, and revealed an improved storage stability property, compared to free enzyme sample counterpart. The addition of metal ions, such as K(+) and Mg(2+) did not affect positively immobilization yield results, but on the contrary, contributed to an improved bio-activities of the immobilized cellulase, thus may be employed before each enzyme application. The method developed in this study offers a cheap and effective alternative for immediate enzyme isolation from the production medium and its stabilization, compared to other carriers used for the immobilization.
Yu, Kyung O.; Fisher, Jeff W.; Burton, G. Allen; Tillitt, Donald E.
1997-01-01
A rat hepatoma cell line, H4IIE serves as a bioassay tool to assess the potential toxicity of dioxin-like chemicals, including polychlorinated biphenyls (PCB) in environmental samples. PCB exposure to these cells induces cytochrome (CYP) P4501A1 activity in a dose-dependent fashion, thus allowing assessment of mixtures. The objective of this study was to determine the effect of different carriers, dimethyl sulfoxide (DMSO) and isooctane on the concentrations of PCBs in the H411E cells and induction of CYPIA1 activity as measured by ethoxyresorufm O-deethylase (EROD) activity. H4IIE cells were dosed with three micrograms of UL-14C-PCB77/ plate dissolved in DMSO or isooctane, and were harvested at sequential time periods for 4 days. PCB77 concentration and EROD activity were measured in the cells. EROD activity was greater when using DMSO as compared to isooctane, while there was no difference in the distribution of PCB77-derived radioactivities within the cell culture system based upon the carrier solvent used to deliver PCB77.
NASA Astrophysics Data System (ADS)
Matin, M.; Mondal, Rajib; Barman, N.; Thamizhavel, A.; Dhar, S. K.
2018-05-01
Here, we report an extremely large positive magnetoresistance (XMR) in a single-crystal sample of MoSi2, approaching almost 107% at 2 K in a 14-T magnetic field without appreciable saturation. Hall resistivity data reveal an uncompensated nature of MoSi2 with an electron-hole compensation level sufficient enough to expect strong saturation of magnetoresistance in the high-field regime. Magnetotransport and the complementary de Haas-van Alphen (dHvA) oscillations results, however, suggest that strong Zeeman effect causes a magnetic field-induced modulation of the Fermi pockets and drives the system towards perfect electron-hole compensation condition in the high-field regime. Thus, the nonsaturating XMR of this semimetal arises under the unconventional situation of Zeeman effect-driven electron-hole compensation, whereas its huge magnitude is decided solely by the ultralarge value of the carrier mobility. Intrinsic ultralarge carrier mobility, strong suppression of backward scattering of the charge carriers, and nontrivial Berry phase in dHvA oscillations attest to the topological character of MoSi2. Therefore, this semimetal represents another material hosting combination of topological and conventional electronic phases.
Srivastava, Deepanshu; Norman, Colin; Azough, Feridoon; Schäfer, Marion C; Guilmeau, Emmanuel; Kepaptsoglou, Demie; Ramasse, Quentin M; Nicotra, Giuseppe; Freer, Robert
2016-09-29
Ceramics based on Sr 0.8 La 0.067 Ti 0.8 Nb 0.2 O 3-δ have been prepared by the mixed oxide route. The La 1/3 NbO 3 component generates ∼13.4% A-site vacancies; this was fixed for all samples. Powders were sintered under air and reducing conditions at 1450 to 1700 K; products were of high density (>90% theoretical). Processing under reducing conditions led to the formation of a Ti 1-x Nb x O 2-y second phase, core-shell structures and oxygen deficiency. X-ray diffraction (XRD) confirmed a simple cubic structure with space group Pm3[combining macron]m. Transmission electron microscopy revealed a high density of dislocations while analytical scanning transmission electron microscopy at atomic resolution demonstrated a uniform distribution of La, Nb and vacancies in the lattice. X-ray photoemission spectroscopy and thermogravimetry showed the oxygen deficiency (δ value) to be ∼0.08 in reduced samples with enhanced carrier concentrations ∼2 × 10 21 cm -3 . Both carrier concentration and carrier mobility increased with sintering time, giving a maximum figure of merit (ZT) of 0.25. Selective additional doping by La or Nb, with no additional A site vacancies, led to the creation of additional carriers and reduced electrical resistivity. Together these led to enhanced ZT values of 0.345 at 1000 K. The contributions from oxygen vacancies and charge carriers have been investigated independently.
Probing charge transfer during metal-insulator transitions in graphene-LaAlO3/SrTiO3 systems
NASA Astrophysics Data System (ADS)
Aliaj, I.; Sambri, A.; Miseikis, V.; Stornaiuolo, D.; di Gennaro, E.; Coletti, C.; Pellegrini, V.; Miletto Granozio, F.; Roddaro, S.
2018-06-01
Two-dimensional electron systems (2DESs) at the interface between LaAlO3 (LAO) and SrTiO3 (STO) perovskite oxides display a wide class of tunable phenomena ranging from superconductivity to metal-insulator transitions. Most of these effects are strongly sensitive to surface physics and often involve charge transfer mechanisms, which are, however, hard to detect. In this work, we realize hybrid field-effect devices where graphene is used to modulate the transport properties of the LAO/STO 2DES. Different from a conventional gate, graphene is semimetallic and allows us to probe charge transfer with the oxide structure underneath the field-effect electrode. In LAO/STO samples with a low initial carrier density, graphene-covered regions turn insulating when the temperature is lowered to 3 K, but conduction can be restored in the oxide structure by increasing the temperature or by field effect. The evolution of graphene's electron density is found to be inconsistent with a depletion of LAO/STO, but it rather points to a localization of interfacial carriers in the oxide structure.
NASA Astrophysics Data System (ADS)
Kang, Soo-Min; Kim, Chang-Hun; Han, Sang-Kook
2016-02-01
In passive optical network (PON), orthogonal frequency division multiplexing (OFDM) has been studied actively due to its advantages such as high spectra efficiency (SE), dynamic resource allocation in time or frequency domain, and dispersion robustness. However, orthogonal frequency division multiple access (OFDMA)-PON requires tight synchronization among multiple access signals. If not, frequency orthogonality could not be maintained. Also its sidelobe causes inter-channel interference (ICI) to adjacent channel. To prevent ICI caused by high sidelobes, guard band (GB) is usually used which degrades SE. Thus, OFDMA-PON is not suitable for asynchronous uplink transmission in optical access network. In this paper, we propose intensity modulation/direct detection (IM/DD) based universal filtered multi-carrier (UFMC) PON for asynchronous multiple access. The UFMC uses subband filtering to subsets of subcarriers. Since it reduces sidelobe of each subband by applying subband filtering, it could achieve better performance compared to OFDM. For the experimental demonstration, different sample delay was applied to subbands to implement asynchronous transmission condition. As a result, time synchronization robustness of UFMC was verified in asynchronous multiple access system.
Hao, Xiaohong; Hu, Xixue; Zhang, Cuimiao; Chen, Shizhu; Li, Zhenhua; Yang, Xinjian; Liu, Huifang; Jia, Guang; Liu, Dandan; Ge, Kun; Liang, Xing-Jie; Zhang, Jinchao
2015-10-27
Potential bioaccumulation is one of the biggest limitations for silica nanodrug delivery systems in cancer therapy. In this study, a mesoporous silica nanoparticles/hydroxyapatite (MSNs/HAP) hybrid drug carrier, which enhanced the biodegradability of silica, was developed by a one-step method. The morphology and structure of the nanoparticles were characterized by TEM, DLS, FT-IR, XRD, N2 adsorption-desorption isotherms, and XPS, and the drug loading and release behaviors were tested. TEM and ICP-OES results indicate that the degradability of the nanoparticles has been significantly improved by Ca(2+) escape from the skeleton in an acid environment. The MSNs/HAP sample exhibits a higher drug loading content of about 5 times that of MSNs. The biological experiment results show that the MSNs/HAP not only exhibits good biocompatibility and antitumor effect but also greatly reduces the side effects of free DOX. The as-synthesized hybrid nanoparticles may act as a promising drug delivery system due to their good biocompatibility, high drug loading efficiency, pH sensitivity, and excellent biodegradability.
Wagner, Bjoern; Fischer, Holger; Kansy, Manfred; Seelig, Anna; Assmus, Frauke
2015-02-20
Here we present a miniaturized assay, referred to as Carrier-Mediated Distribution System (CAMDIS) for fast and reliable measurement of octanol/water distribution coefficients, log D(oct). By introducing a filter support for octanol, phase separation from water is facilitated and the tendency of emulsion formation (emulsification) at the interface is reduced. A guideline for the best practice of CAMDIS is given, describing a strategy to manage drug adsorption at the filter-supported octanol/buffer interface. We validated the assay on a set of 52 structurally diverse drugs with known shake flask log D(oct) values. Excellent agreement with literature data (r(2) = 0.996, standard error of estimate, SEE = 0.111), high reproducibility (standard deviation, SD < 0.1 log D(oct) units), minimal sample consumption (10 μL of 100 μM DMSO stock solution) and a broad analytical range (log D(oct) range = -0.5 to 4.2) make CAMDIS a valuable tool for the high-throughput assessment of log D(oc)t. Copyright © 2014 Elsevier B.V. All rights reserved.
Drawings of the Modular Equipment Transporter and Hand Tool Carrier
1970-10-12
S70-50762 (November 1970) --- A line drawing illustrating layout view of the modular equipment transporter (MET) and its equipment. A MET (or Rickshaw, as it has been nicknamed) will be used on the lunar surface for the first time during the Apollo 14 lunar landing mission. The Rickshaw will serve as a portable workbench with a place for the Apollo lunar hand tools (ALHT) and their carrier, three cameras, two sample container bags, a special environment sample container (SESC), a lunar portable magnetometer (LPM) and spare film magazines.
Capsule injection system for a hydraulic capsule pipelining system
Liu, Henry
1982-01-01
An injection system for injecting capsules into a hydraulic capsule pipelining system, the pipelining system comprising a pipeline adapted for flow of a carrier liquid therethrough, and capsules adapted to be transported through the pipeline by the carrier liquid flowing through the pipeline. The injection system comprises a reservoir of carrier liquid, the pipeline extending within the reservoir and extending downstream out of the reservoir, and a magazine in the reservoir for holding capsules in a series, one above another, for injection into the pipeline in the reservoir. The magazine has a lower end in communication with the pipeline in the reservoir for delivery of capsules from the magazine into the pipeline.
Avian cholera exposure and carriers in greater white-fronted geese breeding in Alaska, USA
Samuel, M.D.; Shadduck, D.J.; Goldberg, Diana R.
2005-01-01
We conducted a 3-yr study (2001a??03) on greater white-fronted geese (Anser albifrons frontalis) breeding in Alaska, USA, to determine the exposure of this population to Pasteurella multocida and the potential role of these birds as disease carriers. We tested sera from nearly 600 adult geese for antibodies to P. multocida serotype 1. We found a low prevalence (<5%) of positive antibodies in adult geese, and based on the short duration of detectable antibodies, these findings indicate recent infection with P. multocida. Prevalence was similar to serologic results from both breeding and wintering lesser snow geese. We also collected oral (n=1,035), nasal (n=102), and cloacal (n=90) swab samples to determine the presence of avian cholera carriers in this population. We were unable to isolate P. multocida serotype 1 from any of the birds sampled. Based on comparison with other waterfowl species, we concluded that these geese may be exposed to avian cholera during the winter or spring migration but are unlikely to play a significant role as carriers of the bacterium causing avian cholera.
Watanabe, Kentaro; Nagata, Takahiro; Oh, Seungjun; Wakayama, Yutaka; Sekiguchi, Takashi; Volk, János; Nakamura, Yoshiaki
2016-01-01
Future one-dimensional electronics require single-crystalline semiconductor free-standing nanorods grown with uniform electrical properties. However, this is currently unrealistic as each crystallographic plane of a nanorod grows at unique incorporation rates of environmental dopants, which forms axial and lateral growth sectors with different carrier concentrations. Here we propose a series of techniques that micro-sample a free-standing nanorod of interest, fabricate its arbitrary cross-sections by controlling focused ion beam incidence orientation, and visualize its internal carrier concentration map. ZnO nanorods are grown by selective area homoepitaxy in precursor aqueous solution, each of which has a (0001):+c top-plane and six {1–100}:m side-planes. Near-band-edge cathodoluminescence nanospectroscopy evaluates carrier concentration map within a nanorod at high spatial resolution (60 nm) and high sensitivity. It also visualizes +c and m growth sectors at arbitrary nanorod cross-section and history of local transient growth events within each growth sector. Our technique paves the way for well-defined bottom-up nanoelectronics. PMID:26881966
NASA Astrophysics Data System (ADS)
Zalogin, Stanislav M.; Zalogin, M. S.
1997-02-01
The problem for construction of control algorithm in OEST the information track of the optical record carrier the realization of which is based on the use of accelerations is considered. Such control algorithms render the designed system the properties of adaptability, feeble sensitivity to the system parameter change and the action of disturbing forces what gives known advantages to information carriers with such system under operation in hard climate conditions as well as at maladjustment, workpieces wear and change of friction in the system. In the paper are investigated dynamic characteristics of a closed OEST, it is shown, that the designed stable system with given quality indices is a high-precision one. The validated recommendations as to design of control algorithms parameters are confirmed by results of mathematical simulation of controlled processes. The proposed methods for OEST synthesis on the basis of the control acceleration principle can be recommended for the use at industrial production of optical information record carriers.
ISLE: Intelligent Selection of Loop Electronics. A CLIPS/C++/INGRES integrated application
NASA Technical Reports Server (NTRS)
Fischer, Lynn; Cary, Judson; Currie, Andrew
1990-01-01
The Intelligent Selection of Loop Electronics (ISLE) system is an integrated knowledge-based system that is used to configure, evaluate, and rank possible network carrier equipment known as Digital Loop Carrier (DLC), which will be used to meet the demands of forecasted telephone services. Determining the best carrier systems and carrier architectures, while minimizing the cost, meeting corporate policies and addressing area service demands, has become a formidable task. Network planners and engineers use the ISLE system to assist them in this task of selecting and configuring the appropriate loop electronics equipment for future telephone services. The ISLE application is an integrated system consisting of a knowledge base, implemented in CLIPS (a planner application), C++, and an object database created from existing INGRES database information. The embedibility, performance, and portability of CLIPS provided us with a tool with which to capture, clarify, and refine corporate knowledge and distribute this knowledge within a larger functional system to network planners and engineers throughout U S WEST.
Wild, insectivorous bats might be carriers of Campylobacter spp.
Hazeleger, Wilma C; Jacobs-Reitsma, Wilma F; Lina, Peter H C; de Boer, Albert G; Bosch, Thijs; van Hoek, Angela H A M; Beumer, Rijkelt R
2018-01-01
The transmission cycles of the foodborne pathogens Campylobacter and Salmonella are not fully elucidated. Knowledge of these cycles may help reduce the transmission of these pathogens to humans. The presence of campylobacters and salmonellas was examined in 631 fresh fecal samples of wild insectivorous bats using a specially developed method for the simultaneous isolation of low numbers of these pathogens in small-sized fecal samples (≤ 0.1 g). Salmonella was not detected in the feces samples, but thermotolerant campylobacters were confirmed in 3% (n = 17) of the bats examined and these pathogens were found in six different bat species, at different sites, in different ecosystems during the whole flying season of bats. Molecular typing of the 17 isolated strains indicated C. jejuni (n = 9), C. coli (n = 7) and C. lari (n = 1), including genotypes also found in humans, wildlife, environmental samples and poultry. Six strains showed unique sequence types. This study shows that insectivorous bats are not only carriers of viral pathogens, but they can also be relevant for the transmission of bacterial pathogens. Bats should be considered as carriers and potential transmitters of Campylobacter and, where possible, contact between bats (bat feces) and food or feed should be avoided.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Section 1602.170-1 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES... 1602.170-1 Carrier. Carrier means a voluntary association, corporation, partnership, or other nongovernmental organization which is lawfully engaged in providing, delivering, paying for, or reimbursing the...
Code of Federal Regulations, 2012 CFR
2012-10-01
... Section 1602.170-1 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES... 1602.170-1 Carrier. Carrier means a voluntary association, corporation, partnership, or other nongovernmental organization which is lawfully engaged in providing, delivering, paying for, or reimbursing the...
Code of Federal Regulations, 2013 CFR
2013-10-01
... Section 1602.170-1 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES... 1602.170-1 Carrier. Carrier means a voluntary association, corporation, partnership, or other nongovernmental organization which is lawfully engaged in providing, delivering, paying for, or reimbursing the...
Code of Federal Regulations, 2014 CFR
2014-10-01
... Section 1602.170-1 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES... 1602.170-1 Carrier. Carrier means a voluntary association, corporation, partnership, or other nongovernmental organization which is lawfully engaged in providing, delivering, paying for, or reimbursing the...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-02
... involves air carriers and foreign air carriers maintaining an accounting system to account for the... carriers are further required to submit quarterly reports to TSA that provide an accounting of the fees...
78 FR 63100 - Unified Registration System; Correction
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-23
... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration 49 CFR Part 390 [Docket... Carrier Safety Administration (FMCSA), DOT. ACTION: Final rule; correction. SUMMARY: FMCSA makes..., Organizational and Conforming Amendments to the Federal Motor Carrier Safety Regulations'' final rule published...
Dual responsive PNIPAM-chitosan targeted magnetic nanopolymers for targeted drug delivery
NASA Astrophysics Data System (ADS)
Yadavalli, Tejabhiram; Ramasamy, Shivaraman; Chandrasekaran, Gopalakrishnan; Michael, Isaac; Therese, Helen Annal; Chennakesavulu, Ramasamy
2015-04-01
A dual stimuli sensitive magnetic hyperthermia based drug delivery system has been developed for targeted cancer treatment. Thermosensitive amine terminated poly-N-isopropylacrylamide complexed with pH sensitive chitosan nanoparticles was prepared as the drug carrier. Folic acid and fluorescein were tagged to the nanopolymer complex via N-hydroxysuccinimide and ethyl-3-(3-dimethylaminopropyl)carbodiimide reaction to form a fluorescent and cancer targeting magnetic carrier system. The formation of the polymer complex was confirmed using infrared spectroscopy. Gadolinium doped nickel ferrite nanoparticles prepared by a hydrothermal method were encapsulated in the polymer complex to form a magnetic drug carrier system. The proton relaxation studies on the magnetic carrier system revealed a 200% increase in the T1 proton relaxation rate. These magnetic carriers were loaded with curcumin using solvent evaporation method with a drug loading efficiency of 86%. Drug loaded nanoparticles were tested for their targeting and anticancer properties on four cancer cell lines with the help of MTT assay. The results indicated apoptosis of cancer cell lines within 3 h of incubation.
Polymeric micelles with stimuli-triggering systems for advanced cancer drug targeting.
Nakayama, Masamichi; Akimoto, Jun; Okano, Teruo
2014-08-01
Since the 1990s, nanoscale drug carriers have played a pivotal role in cancer chemotherapy, acting through passive drug delivery mechanisms and subsequent pharmaceutical action at tumor tissues with reduction of adverse effects. Polymeric micelles, as supramolecular assemblies of amphiphilic polymers, have been considerably developed as promising drug carrier candidates, and a number of clinical studies of anticancer drug-loaded polymeric micelle carriers for cancer chemotherapy applications are now in progress. However, these systems still face several issues; at present, the simultaneous control of target-selective delivery and release of incorporated drugs remains difficult. To resolve these points, the introduction of stimuli-responsive mechanisms to drug carrier systems is believed to be a promising approach to provide better solutions for future tumor drug targeting strategies. As possible trigger signals, biological acidic pH, light, heating/cooling and ultrasound actively play significant roles in signal-triggering drug release and carrier interaction with target cells. This review article summarizes several molecular designs for stimuli-responsive polymeric micelles in response to variation of pH, light and temperature and discusses their potentials as next-generation tumor drug targeting systems.
40 CFR 141.803 - Coliform sampling.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 23 2011-07-01 2011-07-01 false Coliform sampling. 141.803 Section 141...) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.803 Coliform sampling. (a) Analytical methodology. Air carriers must follow the sampling and analysis requirements under this section...
40 CFR 141.803 - Coliform sampling.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Coliform sampling. 141.803 Section 141...) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.803 Coliform sampling. (a) Analytical methodology. Air carriers must follow the sampling and analysis requirements under this section...
Huang, Shanshan; Cheng, Ziyong; Ma, Ping'an; Kang, Xiaojiao; Dai, Yunlu; Lin, Jun
2013-05-14
Luminescent GdVO4:Eu(3+) nanophosphor functionalized mesoporous silica nanoparticles (MSN) were prepared (denoted as GdVO4:Eu(3+)@MSN). The in vitro cytotoxicity tests show that the sample has good biocompatibility, which indicates that the nanocomposite could be a promising candidate for drug delivery. Flow cytometry and confocal laser scanning microscopy (CLSM) confirm that the sample can be effectively taken up by SKOV3 ovarian cancer cells and A549 lung adenocarcinoma cells. It was also shown that the GdVO4:Eu(3+)@MSN brightened the T1-weighted images and enhanced the r1 relaxivity of water protons, which suggested that they could act as T1 contrast agents for magnetic resonance (MR) imaging. It was found that the carriers present a pH-dependent drug release behavior for doxorubicin (DOX). The composites show a red emission under UV irradiation due to the GdVO4:Eu(3+) nanophosphors. Furthermore, the PL intensity of the composite shows correlation with the cumulative release of DOX. These results suggest that the composite can potentially act as a multifunctional drug carrier system with luminescent tagging, MR imaging and pH-controlled release property for DOX.
Khan, Arif O; Aldahmesh, Mohammed A; Meyer, Brian
2008-04-01
To correlate ophthalmic findings with carrier status for a severe Norrie disease (ND) gene mutation (C95F). Prospective interventional case series. Six potential carriers and 1 obligate carrier from a family harboring the mutation. An ophthalmologist blind to the pedigree performed a full ophthalmic examination for the 7 asymptomatic family members. A peripheral blood sample was collected from each for ND gene sequencing. Ophthalmic examination findings (with attention to the presence or absence of retinal findings) and results of ND gene sequencing. Three carriers were identified by molecular genetics, and all 3 of them had peripheral retinal abnormality. However, 3 of the 4 genetically identified noncarriers also exhibited peripheral retinal abnormality. Two of these noncarriers with retinal findings were the offspring of a confirmed noncarrier. The genetically identified noncarrier with a normal peripheral retinal examination was the daughter of an obligate carrier. The presence of peripheral retinal changes was not useful for carrier prediction in a family harboring ND. There are likely additional loci responsible for phenotypic expression.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Yi; Tayebjee, Murad J. Y.; Smyth, Suntrana
2016-03-28
We have investigated the ultrafast carrier dynamics in a 1 μm bulk In{sub 0.265}Ga{sub 0.735}N thin film grown using energetic neutral atom-beam lithography/epitaxy molecular beam epitaxy. Cathodoluminescence and X-ray diffraction experiments are used to observe the existence of indium-rich domains in the sample. These domains give rise to a second carrier population and bi-exponential carrier cooling is observed with characteristic lifetimes of 1.6 and 14 ps at a carrier density of 1.3 × 10{sup 16 }cm{sup −3}. A combination of band-filling, screening, and hot-phonon effects gives rise to a two-fold enhanced mono-exponential cooling rate of 28 ps at a carrier density of 8.4 × 10{sup 18 }cm{sup −3}. Thismore » is the longest carrier thermalization time observed in bulk InGaN alloys to date.« less
Colloidal drug delivery systems: current status and future directions.
Garg, Tarun; Rath, Goutam; Goyal, Amit Kumar
2015-01-01
In this paper, we provide an overview an extensive range of colloidal drug delivery systems with special focus on vesicular and particulates systems that are being used in research or might be potentially useful as carriers systems for drug or active biomolecules or as cell carriers with application in the therapeutic field. We present some important examples of commercially available drug delivery systems with applications in research or in clinical fields. This class of systems is widely used due to excellent drug targeting, sustained and controlled release behavior, higher entrapment efficiency of drug molecules, prevention of drug hydrolysis or enzymatic degradation, and improvement of therapeutic efficacy. These characteristics help in the selection of suitable carrier systems for drug, cell, and gene delivery in different fields.
Cosmic radiation exposure of biological test systems during the EXPOSE-E mission.
Berger, Thomas; Hajek, Michael; Bilski, Pawel; Körner, Christine; Vanhavere, Filip; Reitz, Günther
2012-05-01
In the frame of the EXPOSE-E mission on the Columbus external payload facility EuTEF on board the International Space Station, passive thermoluminescence dosimeters were applied to measure the radiation exposure of biological samples. The detectors were located either as stacks next to biological specimens to determine the depth dose distribution or beneath the sample carriers to determine the dose levels for maximum shielding. The maximum mission dose measured in the upper layer of the depth dose part of the experiment amounted to 238±10 mGy, which relates to an average dose rate of 408±16 μGy/d. In these stacks of about 8 mm height, the dose decreased by 5-12% with depth. The maximum dose measured beneath the sample carriers was 215±16 mGy, which amounts to an average dose rate of 368±27 μGy/d. These values are close to those assessed for the interior of the Columbus module and demonstrate the high shielding of the biological experiments within the EXPOSE-E facility. Besides the shielding by the EXPOSE-E hardware itself, additional shielding was experienced by the external structures adjacent to EXPOSE-E, such as EuTEF and Columbus. This led to a dose gradient over the entire exposure area, from 215±16 mGy for the lowest to 121±6 mGy for maximum shielding. Hence, the doses perceived by the biological samples inside EXPOSE-E varied by 70% (from lowest to highest dose). As a consequence of the high shielding, the biological samples were predominantly exposed to galactic cosmic heavy ions, while electrons and a significant fraction of protons of the radiation belts and solar wind did not reach the samples.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-17
...-0392] Proposed Enhancements to the Motor Carrier Safety Measurement System (SMS) Public Web Site AGENCY... proposed enhancements to the display of information on the Agency's Safety Measurement System (SMS) public Web site. On December 6, 2013, Advocates [[Page 76392
47 CFR 15.207 - Conducted limits.
Code of Federal Regulations, 2010 CFR
2010-10-01
... apply to carrier current systems operating as intentional radiators on frequencies below 30 MHz. In lieu... current system containing their fundamental emission within the frequency band 535-1705 kHz and intended.../50 ohms LISN. (3) Carrier current systems operating below 30 MHz are also subject to the radiated...
Features of Stationary Photoconductivity of High-Ohmic Semiconductors Under Local Illumination
NASA Astrophysics Data System (ADS)
Lysenko, A. P.; Belov, A. G.; Kanevskii, V. E.; Odintsova, E. A.
2018-04-01
Photoconductivity has been thoroughly studied for a long time. However, most researchers have examined photoconductivity of semiconductors while illuminating the entire surface of samples. The present paper examines the effect of local exposure that ensures a high level of injection of free charge carriers upon the conductivity of high-ohmic cadmium telluride and semi-insulating gallium arsenide samples and upon the properties of ohmic contacts to samples. The authors found that regardless of the exposure area the value of transition resistance of ohmic contacts decreases and the concentration of the main charge carriers increases in the sample in proportion to radiation intensity. This research uncovered a number of previously unknown effects that are interesting from the physical point of view. This paper focuses on discussing these effects.
Gautam, Aarti; Kumar, Raina; Dimitrov, George; Hoke, Allison; Hammamieh, Rasha; Jett, Marti
2016-10-01
miRNAs act as important regulators of gene expression by promoting mRNA degradation or by attenuating protein translation. Since miRNAs are stably expressed in bodily fluids, there is growing interest in profiling these miRNAs, as it is minimally invasive and cost-effective as a diagnostic matrix. A technical hurdle in studying miRNA dynamics is the ability to reliably extract miRNA as small sample volumes and low RNA abundance create challenges for extraction and downstream applications. The purpose of this study was to develop a pipeline for the recovery of miRNA using small volumes of archived serum samples. The RNA was extracted employing several widely utilized RNA isolation kits/methods with and without addition of a carrier. The small RNA library preparation was carried out using Illumina TruSeq small RNA kit and sequencing was carried out using Illumina platform. A fraction of five microliters of total RNA was used for library preparation as quantification is below the detection limit. We were able to profile miRNA levels in serum from all the methods tested. We found out that addition of nucleic acid based carrier molecules had higher numbers of processed reads but it did not enhance the mapping of any miRBase annotated sequences. However, some of the extraction procedures offer certain advantages: RNA extracted by TRIzol seemed to align to the miRBase best; extractions using TRIzol with carrier yielded higher miRNA-to-small RNA ratios. Nuclease free glycogen can be carrier of choice for miRNA sequencing. Our findings illustrate that miRNA extraction and quantification is influenced by the choice of methodologies. Addition of nucleic acid- based carrier molecules during extraction procedure is not a good choice when assaying miRNA using sequencing. The careful selection of an extraction method permits the archived serum samples to become valuable resources for high-throughput applications.
Presolar Organic Globules in Astromaterials
NASA Technical Reports Server (NTRS)
Nakamura-Messenger, K.; Messenger, S.; Keller, L. P.; Clemett, S. J.
2012-01-01
Presolar grains were identified in meteorite residues 20 years ago based on their exotic isotopic compositions [1]. Their study has provide new insights into stellar evolution and the first view of the original building blocks of the solar system. Organic matter in meteorites and IDPs is highly enriched in D/H and N-15/N-14 at micron scales, possibly due to presolar organic grains [2-4]. These anomalies are ascribed to the partial preservation of presolar cold molecular cloud material. Identifying the carriers of these anomalies and elucidating their physical and chemical properties may give new views of interstellar chemistry and better understanding of the original components of the protosolar disk. However, identifying the carriers has been hampered by their small size and the inability to chemically isolate them. Thanks to major advances in nano-scale analytical techniques and advanced sample preparation, we were able to show that in the Tagish Lake meteorite, the principle carriers of these isotopic anomalies are sub-microns, hollow organic globules [5]. The organic globules likely formed by photochemical processing of organic ices in a cold molecular cloud or the outermost regions of the protosolar disk [5]. Organic globules with similar physical, chemical, and isotopic properties are also recently found from Bells CM2 carbonaceous chondrite, in IDPs [6] and in the comet Wild-2 samples returned by Stardust [7]. These results support the view that microscopic organic grains were widespread constituents of the protoplanetary disk. Their exotic isotopic compositions trace their origins to the outermost portions of the protosolar disk or a presolar cold molecular cloud.
DOT National Transportation Integrated Search
2017-04-01
The Federal Motor Carrier Safety Administration (FMCSA), in cooperation with the John A. Volpe National Transportation Systems Center (Volpe), has developed a quantitative model to measure the effectiveness of motor carrier interventions in terms of ...
On the photoresponse of several novel functionalized oligoacene and anthradithiophene derivatives
NASA Astrophysics Data System (ADS)
Day, Jonathan
The results of an investigation into carrier dynamics in several novel functionalized and solution-processable pentacene and anthradithiophene derivatives are reported. Measurements were made of real-time photoresponse of polycrystalline thin films of these materials to ultrafast laser pulses, on picosecond to microsecond time-scales, as well as measurements of dark current and current under steady illumination. This data was taken over varied field-strength, light intensity and temperature. The results support a model for carrier generation and transport with the following features. Carrier photo-generation is assisted weakly, if it is assisted at all, thermally or by applied fields. Carriers are initially (picosecond to nanosecond time-scales) in extended states and transport is "bandlike." Carriers then relax into more localized states, transported via thermally assisted hopping (nanosecond to second time-scales). This model was supported by further experiments with the electric behavior of films prepared from a pure anthradithophene derivative, doped with either the buckminsterfullerene C60 or with other molecular dopants. These results also show that samples with traps of known density and depth can be prepared, as a means of manipulating transport dynamics. The electronic and photo-electronic behaviors of films with self-anodized aluminum and of films with gold electrodes were compared, and a model of the particular energy profile and dynamics which exist at the different interfaces between the films and the different contacts was developed. This model views the metal-organic-metal system as an anode-to-anode Schottky strucure, whose I-V relation is shaped both by the nature of the interface dynamics for different metal contacts, and by the different distributions of space-charge in the thin film between different electrodes.
49 CFR 393.209 - Steering wheel systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS PARTS AND ACCESSORIES...) Steering column. The steering column must be securely fastened. (d) Steering system. Universal joints and...
49 CFR 393.209 - Steering wheel systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS PARTS AND ACCESSORIES...) Steering column. The steering column must be securely fastened. (d) Steering system. Universal joints and...
49 CFR 393.209 - Steering wheel systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS PARTS AND ACCESSORIES...) Steering column. The steering column must be securely fastened. (d) Steering system. Universal joints and...
49 CFR 393.209 - Steering wheel systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS PARTS AND ACCESSORIES...) Steering column. The steering column must be securely fastened. (d) Steering system. Universal joints and...
49 CFR 393.209 - Steering wheel systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS PARTS AND ACCESSORIES...) Steering column. The steering column must be securely fastened. (d) Steering system. Universal joints and...
Smith, Stephen F.; Moore, James A.
2003-05-13
Systems and methods are described for carrier-frequency synchronization for improved AM and TV broadcast reception. A method includes synchronizing a carrier frequency of a broadcast signal with a remote reference frequency. An apparatus includes a reference signal receiver; a phase comparator coupled to the reference signal receiver; a voltage controlled oscillator coupled to the phase comparator; and a radio frequency output coupled to the voltage controlled oscillator.
Materials experiment carrier concepts definition study. Volume 2: Technical report, part 2
NASA Technical Reports Server (NTRS)
1981-01-01
A materials experiment carrier (MEC) that provides effective accommodation of the given baseline materials processing in space (MPS) payloads and demonstration of the MPS platform concept for high priority materials processing science, multidiscipline MPS investigations, host carrier for commercial MPS payloads, and system economy of orbital operations is defined. The study flow of task work is shown. Study tasks featured analysis and trades to identify the MEC system concept options.
Ultrasonic speech translator and communications system
Akerman, M.A.; Ayers, C.W.; Haynes, H.D.
1996-07-23
A wireless communication system undetectable by radio frequency methods for converting audio signals, including human voice, to electronic signals in the ultrasonic frequency range, transmitting the ultrasonic signal by way of acoustical pressure waves across a carrier medium, including gases, liquids, or solids, and reconverting the ultrasonic acoustical pressure waves back to the original audio signal. The ultrasonic speech translator and communication system includes an ultrasonic transmitting device and an ultrasonic receiving device. The ultrasonic transmitting device accepts as input an audio signal such as human voice input from a microphone or tape deck. The ultrasonic transmitting device frequency modulates an ultrasonic carrier signal with the audio signal producing a frequency modulated ultrasonic carrier signal, which is transmitted via acoustical pressure waves across a carrier medium such as gases, liquids or solids. The ultrasonic receiving device converts the frequency modulated ultrasonic acoustical pressure waves to a frequency modulated electronic signal, demodulates the audio signal from the ultrasonic carrier signal, and conditions the demodulated audio signal to reproduce the original audio signal at its output. 7 figs.
From Composition to Cure: A Systems Engineering Approach to Anticancer Drug Carriers.
MacEwan, Sarah R; Chilkoti, Ashutosh
2017-06-06
The molecular complexity and heterogeneity of cancer has led to a persistent, and as yet unsolved, challenge to develop cures for this disease. The pharmaceutical industry focuses the bulk of its efforts on the development of new drugs, but an alternative approach is to improve the delivery of existing drugs with drug carriers that can manipulate when, where, and how a drug exerts its therapeutic effect. For the treatment of solid tumors, systemically delivered drug carriers face significant challenges that are imposed by the pathophysiological barriers that lie between their site of administration and their site of therapeutic action in the tumor. Furthermore, drug carriers face additional challenges in their translation from preclinical validation to clinical approval and adoption. Addressing this diverse network of challenges requires a systems engineering approach for the rational design of optimized carriers that have a realistic prospect for translation from the laboratory to the patient. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hydrogen purification systems for PEM fuel cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Varma, Arvind; Hwang, Hyun Tae; Al-Kukhun, Ahmad
A system for generating and purifying hydrogen. To generate hydrogen, the system includes inlets configured to receive a hydrogen carrier and an inert insulator, a mixing chamber configured to combine the hydrogen carrier and the inert insulator, a heat exchanger configured to apply heat to the mixture of hydrogen carrier and the inert insulator, wherein the applied heat results in the generation of hydrogen from the hydrogen carrier, and an outlet configured to release the generated hydrogen. To purify hydrogen, the system includes a primary inlet to receive a starting material and an ammonia filtration subassembly, which may include anmore » absorption column configured to absorb the ammonia into water for providing purified hydrogen at a first purity level. The ammonia filtration subassembly may also include an adsorbent member configured to adsorb ammonia from the starting material into an adsorbent for providing purified hydrogen at a second purity level.« less
NASA Technical Reports Server (NTRS)
Smith, G. A.; Meyer, G.
1980-01-01
The results of a simulation study of an alternative design concept for an automatic landing control system are presented. The alternative design concept for an automatic landing control system is described. The design concept is the total aircraft flight control system (TAFCOS). TAFCOS is an open loop, feed forward system that commands the proper instantaneous thrust, angle of attack, and roll angle to achieve the forces required to follow the desired trajector. These dynamic trim conditions are determined by an inversion of the aircraft nonlinear force characteristics. The concept was applied to an A-7E aircraft approaching an aircraft carrier. The implementation details with an airborne digital computer are discussed. The automatic carrier landing situation is described. The simulation results are presented for a carrier approach with atmospheric disturbances, an approach with no disturbances, and for tailwind and headwind gusts.
Adaptive Resampling Particle Filters for GPS Carrier-Phase Navigation and Collision Avoidance System
NASA Astrophysics Data System (ADS)
Hwang, Soon Sik
This dissertation addresses three problems: 1) adaptive resampling technique (ART) for Particle Filters, 2) precise relative positioning using Global Positioning System (GPS) Carrier-Phase (CP) measurements applied to nonlinear integer resolution problem for GPS CP navigation using Particle Filters, and 3) collision detection system based on GPS CP broadcasts. First, Monte Carlo filters, called Particle Filters (PF), are widely used where the system is non-linear and non-Gaussian. In real-time applications, their estimation accuracies and efficiencies are significantly affected by the number of particles and the scheduling of relocating weights and samples, the so-called resampling step. In this dissertation, the appropriate number of particles is estimated adaptively such that the error of the sample mean and variance stay in bounds. These bounds are given by the confidence interval of a normal probability distribution for a multi-variate state. Two required number of samples maintaining the mean and variance error within the bounds are derived. The time of resampling is determined when the required sample number for the variance error crosses the required sample number for the mean error. Second, the PF using GPS CP measurements with adaptive resampling is applied to precise relative navigation between two GPS antennas. In order to make use of CP measurements for navigation, the unknown number of cycles between GPS antennas, the so called integer ambiguity, should be resolved. The PF is applied to this integer ambiguity resolution problem where the relative navigation states estimation involves nonlinear observations and nonlinear dynamics equation. Using the PF, the probability density function of the states is estimated by sampling from the position and velocity space and the integer ambiguities are resolved without using the usual hypothesis tests to search for the integer ambiguity. The ART manages the number of position samples and the frequency of the resampling step for real-time kinematics GPS navigation. The experimental results demonstrate the performance of the ART and the insensitivity of the proposed approach to GPS CP cycle-slips. Third, the GPS has great potential for the development of new collision avoidance systems and is being considered for the next generation Traffic alert and Collision Avoidance System (TCAS). The current TCAS equipment, is capable of broadcasting GPS code information to nearby airplanes, and also, the collision avoidance system using the navigation information based on GPS code has been studied by researchers. In this dissertation, the aircraft collision detection system using GPS CP information is addressed. The PF with position samples is employed for the CP based relative position estimation problem and the same algorithm can be used to determine the vehicle attitude if multiple GPS antennas are used. For a reliable and enhanced collision avoidance system, three dimensional trajectories are projected using the estimates of the relative position, velocity, and the attitude. It is shown that the performance of GPS CP based collision detecting algorithm meets the accuracy requirements for a precise approach of flight for auto landing with significantly less unnecessary collision false alarms and no miss alarms.
McAlexander, Melissa A.; Phillips, Maggie J.; Witwer, Kenneth W.
2013-01-01
Interest in extracellular RNA (exRNA) has intensified as evidence accumulates that these molecules may be useful as indicators of a wide variety of biological conditions. To establish specific exRNA molecules as clinically relevant biomarkers, reproducible recovery from biological samples and reliable measurements of the isolated RNA are paramount. Toward these ends, careful and rigorous comparisons of technical procedures are needed at all steps from sample handling to RNA isolation to RNA measurement protocols. In the investigations described in this methods paper, RT-qPCR was used to examine the apparent recovery of specific endogenous miRNAs and a spiked-in synthetic RNA from blood plasma samples. RNA was isolated using several widely used RNA isolation kits, with or without the addition of glycogen as a carrier. Kits examined included total RNA isolation systems that have been commercially available for several years and commonly adapted for extraction of biofluid RNA, as well as more recently introduced biofluids-specific RNA methods. Our conclusions include the following: some RNA isolation methods appear to be superior to others for the recovery of RNA from biological fluids; addition of a carrier molecule seems to be beneficial for some but not all isolation methods; and quantitative recovery of RNA is observed from increasing volumes of cerebrospinal fluid. PMID:23720669
NASA Astrophysics Data System (ADS)
Jia, Bo Wen; Tan, Kian Hua; Loke, Wan Khai; Wicaksono, Satrio; Yoon, Soon Fatt
2018-01-01
This work presents the effects of in situ thermal annealing under antimony overpressure on the structural, electrical, and optical properties of III-Sb (GaSb and InSb) grown on (100) GaAs using an interfacial misfit array to accommodate the lattice mismatch. Both the sample growth and the in situ thermal annealing were carried out in the in the molecular beam epitaxy system, and the temperature of the as-grown sample was increased to exceed its growth temperature during the annealing. X-ray diffraction demonstrates nearly fully relaxed as-grown and annealed III-Sb layers. The optimal annealing temperatures and durations are for 590 °C, 5 min for GaSb and 420 °C, 15 min for InSb, respectively. In situ annealing decreased the surface roughness of the III-Sb layers. X-ray reciprocal space mapping and transmission electron microscopy observation showed stable interfacial misfit arrays, and no interfacial diffusion occurred in the annealed III-Sb layers. A Hall measurement of unintentionally doped III-Sb layers showed greater carrier mobility and a lower carrier concentration in the annealed samples at both 77 and 300 K. In situ annealing improved the photoresponsivity of GaSb and InSb photoconductors grown on GaAs in the near- and mid-infrared ranges, respectively.
Carrier-mediated transport of riboflavin in the rat colon.
Yuasa, H; Hirobe, M; Tomei, S; Watanabe, J
2000-03-01
Carriers involved in riboflavin transport have generally been presumed to be localized in the upper small intestine. However, using a closed loop technique, we found that in the rat colon the absorption of riboflavin could be significantly reduced by raising the concentration from 0.1 to 200 microM and by adding lumiflavin, an analogue of riboflavin. These results suggest that saturable transport by the carrier that is specific for riboflavin and analogues may also be involved in riboflavin absorption in the colon. At the lower concentration of 0.1 microM, carrier-mediated transport was suggested to prevail, compared with passive transport, both in the colon and the small intestine. Furthermore, carrier-mediated transport in the colon was comparable with that in the small intestine. This study is the first to suggest carrier-mediated riboflavin transport in the colon. Although the riboflavin transport system in the colon needs to be subjected to more detailed investigation of its transport functions and role in riboflavin absorption after oral administration, it would be of interest to explore potential use of this carrier as a system for drug delivery.
HPMA Copolymer-Drug Conjugates with Controlled Tumor-Specific Drug Release.
Chytil, Petr; Koziolová, Eva; Etrych, Tomáš; Ulbrich, Karel
2018-01-01
Over the past few decades, numerous polymer drug carrier systems are designed and synthesized, and their properties are evaluated. Many of these systems are based on water-soluble polymer carriers of low-molecular-weight drugs and compounds, e.g., cytostatic agents, anti-inflammatory drugs, or multidrug resistance inhibitors, all covalently bound to a carrier by a biodegradable spacer that enables controlled release of the active molecule to achieve the desired pharmacological effect. Among others, the synthetic polymer carriers based on N-(2-hydroxypropyl) methacrylamide (HPMA) copolymers are some of the most promising carriers for this purpose. This review focuses on advances in the development of HPMA copolymer carriers and their conjugates with anticancer drugs, with triggered drug activation in tumor tissue and especially in tumor cells. Specifically, this review highlights the improvements in polymer drug carrier design with respect to the structure of a spacer to influence controlled drug release and activation, and its impact on the drug pharmacokinetics, enhanced tumor uptake, cellular trafficking, and in vivo antitumor activity. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Tuning the charge carrier density in the thermoelectric colusite
NASA Astrophysics Data System (ADS)
Kim, Fiseong S.; Suekuni, Koichiro; Nishiate, Hirotaka; Ohta, Michihiro; Tanaka, Hiromi I.; Takabatake, Toshiro
2016-05-01
The colusite Cu26V2Sn6S32 has high potential as a thermoelectric material at medium-high temperatures because of a large Seebeck coefficient (S ≃ 220 μV/K) and rather small electrical resistivity (ρ ≃ 100 μΩm) at 660 K. To improve the thermoelectric performance, we have tuned the hole carrier density p by substituting Zn for Cu in Cu26-xZnxV2Sn6S32 (x = 1-3) and starting with Cu and Sn deficient compositions in Cu26-yV2Sn6S32 (y = 1, 2) and Cu26V2Sn6-zS32 (z = 0.25-1), respectively. Powder x-ray diffraction and electron-probe microanalysis showed that the Zn-substituted samples and Sn-deficient (z ≥ 0.5) samples are formed in a single phase, whereas the Cu26-yV2Sn6S32 samples are composed of two phases with slightly different compositions. Within these samples, the value of p at 300 K varies in the range between 3.6 × 1020 and 2.8 × 1021 cm-3. The relation between p and S led to the effective mass m* of 4-7m0 for the hole carriers. The large S of the colusite is therefore ascribed to the heavy mass carriers of the valence band top. The decreases in p with x and y reduced the dimensionless thermoelectric figure of merit ZT, whereas the increase in p with z raised ZT from 0.56 (z = 0) to 0.62 (z = 0.5) at 660 K.
Lee, Pei-Chen; Rhodes, Shannon L; Sinsheimer, Janet S; Bronstein, Jeff; Ritz, Beate
2013-06-01
We previously demonstrated that carriers of the "slower metabolizer" MM genotype of paraoxonase (PON1) who were also exposed to ambient organophosphate (OP) pesticides at their residences were at increased risk of developing Parkinson's disease (PD). Here, with a larger sample size, we extend our previous investigation to consider additional sources of ambient exposure and examined two additional functional PON1 variants. From 2001 to 2011, we enrolled incident cases of idiopathic PD and population controls living in central California. We genotyped three well-known functional PON1 SNPs: two exonic polymorphisms (PON1L55M and PON1Q192R) and the promoter region variant (PON1C-108T). Ambient exposures to diazinon, chlorpyrifos, and parathion at residential and workplace addresses were assessed using a validated geographic information system-based model incorporating records of agricultural pesticide applications in California. The odds ratio (OR) for Caucasians exposed to OPs at either residential or workplace addresses varied by PON1 genotype; for exposed carriers of the "faster" metabolizer genotypes, ML or LL, we estimated lower odds ratios (range, 1.20-1.39) than for exposed carriers of the "slower" metabolizer genotype MM (range, 1.78-2.45) relative to unexposed carriers of the faster genotypes. We observed similarly increased ORs for exposure across PON1Q192R genotypes, but no differences across PON1C-108T genotypes. The largest ORs were estimated for exposed carriers of both PON1192QQ and PON155MM (OR range, 2.84-3.57). Several functional PON1 variants may act together to modify PD risk for ambient OP exposures. While either PON1L55M or PON1Q192R may be sufficient to identify increased susceptibility, carriers of both slow metabolizer variants seem most susceptible to OP exposures. Copyright © 2013 Elsevier Ltd. All rights reserved.
Electrical Characterization of Thin Film Cadmium Telluride Electrodeposited from Tri-N Telluride
NASA Astrophysics Data System (ADS)
von Windheim, Jesko A.
The electrical transport properties of CdTe electrodeposited from tri-n-butylphosphine telluride have been studied by resistivity and Hall effect measurements. Methods have been developed to reproducibly remove large area samples from their conducting substrates, and these samples were prepared for temperature dependent Hall measurements and resistivity measurements. Apparatus was designed and built to routinely measure Hall voltages as low as 250 muV for source impedances up to 10 ^{12} Omega. The central aspect of the measurement system was a low cost, differential electrometer amplifier designed around the AD549L monolithic electrometer operational amplifier. Temperature control was achieved via a Eurotherm 808 temperature controller, and a cooled stream of nitrogen gas. With this system, temperature could be maintained within +/- 0.5^circC at set points between -40^circC and +40^circC. Data collection, temperature ramping, and power to the magnet were all computer controlled, and resistivity measurements were fully automated. As-annealed electrodeposited CdTe was found to be consistently p-type, with resistivity values typically 10^6- 10^{7 } Omega-cm. Various donor and acceptor dopants have been incorporated into polycrystalline CdTe films by three methods: electrochemical codeposition, electromigration and vapour techniques. The dopants were Cd, Te, Cu, Ag, In, and O_2. The activity of the dopant was dependent on the method that was used for incorporation. Oxygen was found to only have a significant effect when it was incorporated in situ, during deposition. For Cd and Te, on the other hand, little effect was seen when their concentration was varied in situ. However, hole concentration increased substantially when Te was incorporated by diffusion, and a p to n conversion was observed when Cd was incorporated by diffusion. The carrier concentration of p-type CdTe could be systematically increased by increasing the current density for the electromigration of copper. The decreasing carrier concentration was accompanied by a decrease in resistivity and a decrease in mobility. The effect of dopant density on the resistivity of the polycrystalline cadmium telluride films, deposited from tri-n-butylphosphine telluride, can consistently be described by a grain boundary model. In this model charging of grain boundary states results in a barrier and can affect the carrier density. According to the model, dopants accumulated at grain boundaries do not generate carriers and do not affect the density of interface states.
Fat Metabolism in Higher Plants
Jacobson, Bruce S.; Jaworski, J. G.; Stumpf, P. K.
1974-01-01
Stearyl-acyl carrier protein desaturase (EC 1.14.99.6), present in the stroma fraction of spinach (Spinacia oleracea) chloroplasts, rapidly desaturated enzymatically prepared stearyl-acyl carrier protein to oleic acid. No other substrates were desaturated. In addition to stearyl-acyl carrier protein, reduced ferredoxin was an essential component of the system. The electron donor systems were either ascorbate, dichlorophenolindophenol, photosystem I and light, or NADPH and ferredoxin-NADP reductase. The desaturase was more active in extracts prepared from chloroplasts obtained from immature spinach leaves than from mature leaves. Stearyl-acyl carrier protein desaturase also occurs in soluble extracts of avocado (Persea americana Mill.) mesocarp and of developing safflower (Carthamus tinctorius) seeds. PMID:16658913
Polymeric anticancer drugs with pH-controlled activation.
Ulbrich, Karel; Subr, Vladimír
2004-04-23
Use of macromolecular water-soluble carriers of anti-cancer drugs represents a promising approach to cancer therapy. Release of drugs from the carrier system is a prerequisite for therapeutic activity of most macromolecular anti-cancer conjugates. Incorporation of acid-sensitive spacers between the drug and carrier enables release of an active drug from the carrier in a tumor tissue, either in slightly acidic extracellular fluids or, after endocytosis, in endosomes or lysosomes of cancer cells. This paper reviews advances in development and study of properties of various acid-sensitive macromolecular drug delivery systems, starting from simple polymer-drug conjugates to ending with site-specific antibody-targeted polymer-drug conjugates.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-31
... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration Notice of Procedural... Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Notice; extension of effective date. SUMMARY..., Transportation Specialist, Office of Enforcement and Compliance, Federal Motor Carrier Safety Administration...
NASA Technical Reports Server (NTRS)
Daelemans, Gerard; Goldsmith, Theodore
1999-01-01
The NASA/GSFC Shuttle Small Payloads Projects Office (SSPPO) has been studying the feasibility of migrating Hitchhiker customers past present and future to the International Space Station via a "Hitchhiker like" carrier system. SSPPO has been tasked to make the most use of existing hardware and software systems and infrastructure in its study of an ISS based carrier system. This paper summarizes the results of the SSPPO Hitchhiker on International Space Station (ISS) study. Included are a number of "Hitchhiker like" carrier system concepts that take advantage of the various ISS attached payload accommodation sites. Emphasis will be given to a HH concept that attaches to the Japanese Experiment Module - Exposed Facility (JEM-EF).
Pigeons and their droppings as reservoirs of Candida and other zoonotic yeasts.
Rosario Medina, Inmaculada; Román Fuentes, Lorena; Batista Arteaga, Miguel; Real Valcárcel, Fernando; Acosta Arbelo, Félix; Padilla Del Castillo, Daniel; Déniz Suárez, Soraya; Ferrer Quintana, Otilia; Vega Gutiérrez, Belinda; Silva Sergent, Freddy; Acosta-Hernández, Begoña
The importance of pigeons as reservoirs and carriers of Cryptococcus neoformans and other species of this genus is well-known; however, less is known about their role as reservoirs and carriers of other yeasts that impact public health. The present study was performed on Gran Canaria Island to define yeasts other than Cryptococcus spp. that have been reported to impact public health and which could be carried by pigeons. Samples were obtained from 83 pigeon lofts (Columba livia); moreover, 331 crop samples, 331 cloacal samples and 174 dropping samples were collected. In addition, 17 dropping samples were taken from a total of 17 public squares. Samples were inoculated on Sabouraud dextrose agar with chloramphenicol. Different yeast species, i.e. Candida guilliermondii (24.36%), Candida kefyr (1.21%), Saccharomyces cerevisiae (2.43%), and Trichosporon asahii (1.21%) were isolated for the first time from the cloaca. The most frequently isolated yeast from the crop, cloaca and dropping samples from lofts was C. guilliermondii (30.46%, 24.36% and 49.37%, respectively). In addition, for the first time, C. kefyr (3.65%), Candida pelliculosa (2.43%), Candida rugosa (1.21%), T. asahii (3.65%), Trichosporon mucoides (3.65%) and Prototheca wickerhamii (1.21%) were obtained from crop samples; Candida pelliculosa (1.20%), T. asahii (9.63%) and T. mucoides (7.22%) were isolated from dropping samples in the lofts. Candida albicans was the most frequently isolated yeast in dropping samples collected in public squares. It can be assumed that pigeons and their droppings act as carriers and reservoirs of Candida spp. and other zoonotic yeasts. Copyright © 2017 Asociación Española de Micología. Publicado por Elsevier España, S.L.U. All rights reserved.
21 CFR 203.30 - Sample distribution by mail or common carrier.
Code of Federal Regulations, 2011 CFR
2011-04-01
... pharmacy of a hospital or other health care entity, by mail or common carrier, provided that: (1) The... to the pharmacy of a hospital or other health care entity is required to contain, in addition to all of the information in paragraph (b)(l) of this section, the name and address of the pharmacy of the...
21 CFR 203.30 - Sample distribution by mail or common carrier.
Code of Federal Regulations, 2013 CFR
2013-04-01
... pharmacy of a hospital or other health care entity, by mail or common carrier, provided that: (1) The... to the pharmacy of a hospital or other health care entity is required to contain, in addition to all of the information in paragraph (b)(l) of this section, the name and address of the pharmacy of the...
21 CFR 203.30 - Sample distribution by mail or common carrier.
Code of Federal Regulations, 2012 CFR
2012-04-01
... pharmacy of a hospital or other health care entity, by mail or common carrier, provided that: (1) The... to the pharmacy of a hospital or other health care entity is required to contain, in addition to all of the information in paragraph (b)(l) of this section, the name and address of the pharmacy of the...
21 CFR 203.30 - Sample distribution by mail or common carrier.
Code of Federal Regulations, 2014 CFR
2014-04-01
... pharmacy of a hospital or other health care entity, by mail or common carrier, provided that: (1) The... to the pharmacy of a hospital or other health care entity is required to contain, in addition to all of the information in paragraph (b)(l) of this section, the name and address of the pharmacy of the...
de Mattos, Ivanildo Luiz; Zagal, José Heraclito
2010-01-01
A flow injection system using an unmodified gold screen-printed electrode was employed for total phenol determination in black and green teas. In order to avoid passivation of the electrode surface due to the redox reaction, preoxidation of the sample was realized by hexacyanoferrate(III) followed by addition of an EDTA solution. The complex formed in the presence of EDTA minimizes or avoids polymerization of the oxidized phenols. The previously filtered tea sample and hexacyanoferrate(III) reagent were introduced simultaneously into two-carrier streams producing two reproducible zones. At confluence point, the pre-oxidation of the phenolic compounds occurs while this zone flows through the coiled reactor and receives the EDTA solution before phenol detection. The consumption of ferricyanide was monitorized at 360 mV versus Ag/AgCl and reflected the total amount of phenolic compounds present in the sample. Results were reported as gallic acid equivalents (GAEs). The proposed system is robust, versatile, environmentally-friendly (since the reactive is used only in the presence of the sample), and allows the analysis of about 35–40 samples per hour with detection limit = 1 mg/L without the necessity for surface cleaning after each measurement. Precise results are in agreement with those obtained by the Folin-Ciocalteu method. PMID:21461407
van Staden, J Koos F; Mashamba, M Mulalo G; Stefan, R Raluca I
2002-12-06
A potentiometric SI titration system for the determination of total acidity in soft drinks is proposed. The concept is based on the aspiration of the acid soft drink sample between two base zones into a holding coil with the volume of the first base zone twice to that of the second one and channelled by flow reversal through a reaction coil to a potentiometric sensor. A solution of 0.1 mol l(-1) sodium chloride is used as ionic strength adjustment buffer in the carrier stream. The system has been applied to the analysis of some South African soft drinks having a total acidity level of about 0.2-0.3% (w/v). The method has a sample frequency of 45 samples per h with a linear range of 0.1 and 0.6% (w/v). It is easy to use, fully computerised, and gives the results that are comparable to both automated batch titration and manual titration.
Enhanced power factor of higher manganese silicide via melt spin synthesis method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, Xiaoya; Li, Qiang, E-mail: liqiang@bnl.gov; Shi, Xun
We report on the thermoelectric properties of the higher manganese silicide MnSi{sub 1.75} synthesized by means of a one-step non-equilibrium method. The ultrahigh cooling rate generated from the melt-spin technique is found to be effective in reducing second phases, which are inevitable during the traditional solid state diffusion processes. Aside from being detrimental to thermoelectric properties, second phases skew the revealing of the intrinsic properties of this class of materials, for example, the optimal level of carrier concentration. With this melt-spin sample, we are able to formulate a simple model based on a single parabolic band that can well describemore » the carrier concentration dependence of the Seebeck coefficient and power factor of the data reported in the literature. An optimal carrier concentration around 5 × 10{sup 20 }cm{sup −3} at 300 K is predicted according to this model. The phase-pure melt-spin sample shows the largest power factor at high temperature, resulting in the highest zT value among the three samples in this paper.« less
RADIATION FACILITY FOR NUCLEAR REACTORS
Currier, E.L. Jr.; Nicklas, J.H.
1961-12-12
A radiation facility is designed for irradiating samples in close proximity to the core of a nuclear reactor. The facility comprises essentially a tubular member extending through the biological shield of the reactor and containing a manipulatable rod having the sample carrier at its inner end, the carrier being longitudinally movable from a position in close proximity to the reactor core to a position between the inner and outer faces of the shield. Shield plugs are provided within the tubular member to prevent direct radiation from the core emanating therethrough. In this device, samples may be inserted or removed during normal operation of the reactor without exposing personnel to direct radiation from the reactor core. A storage chamber is also provided within the radiation facility to contain an irradiated sample during the period of time required to reduce the radioactivity enough to permit removal of the sample for external handling. (AEC)
Miron, Richard J; Fujioka-Kobayashi, Masako; Buser, Daniel; Zhang, Yufeng; Bosshardt, Dieter D; Sculean, Anton
Collagen barrier membranes were first introduced to regenerative periodontal and oral surgery to prevent fast ingrowing soft tissues (ie, epithelium and connective tissue) into the defect space. More recent attempts have aimed at combining collagen membranes with various biologics/growth factors to speed up the healing process and improve the quality of regenerated tissues. Recently, a new formulation of enamel matrix derivative in a liquid carrier system (Osteogain) has demonstrated improved physico-chemical properties for the adsorption of enamel matrix derivative to facilitate protein adsorption to biomaterials. The aim of this pioneering study was to investigate the use of enamel matrix derivative in a liquid carrier system in combination with collagen barrier membranes for its ability to promote osteoblast cell behavior in vitro. Undifferentiated mouse ST2 stromal bone marrow cells were seeded onto porcine-derived collagen membranes alone (control) or porcine membranes + enamel matrix derivative in a liquid carrier system. Control and enamel matrix derivative-coated membranes were compared for cell recruitment and cell adhesion at 8 hours; cell proliferation at 1, 3, and 5 days; and real-time polymerase chain reaction (PCR) at 3 and 14 days for genes encoding Runx2, collagen1alpha2, alkaline phosphatase, and bone sialoprotein. Furthermore, alizarin red staining was used to investigate mineralization. A significant increase in cell adhesion was observed at 8 hours for barrier membranes coated with enamel matrix derivative in a liquid carrier system, whereas no significant difference could be observed for cell proliferation or cell recruitment. Enamel matrix derivative in a liquid carrier system significantly increased alkaline phosphatase mRNA levels 2.5-fold and collagen1alpha2 levels 1.7-fold at 3 days, as well as bone sialoprotein levels twofold at 14 days postseeding. Furthermore, collagen membranes coated with enamel matrix derivative in a liquid carrier system demonstrated a sixfold increase in alizarin red staining at 14 days when compared with collagen membrane alone. The combination of enamel matrix derivative in a liquid carrier system with a barrier membrane significantly increased cell attachment, differentiation, and mineralization of osteoblasts in vitro. Future animal testing is required to fully characterize the additional benefits of combining enamel matrix derivative in a liquid carrier system with a barrier membrane for guided bone or tissue regeneration.
Puglia, Carmelo; Lauro, Maria Rosaria; Offerta, Alessia; Crascì, Lucia; Micicchè, Lucia; Panico, Anna Maria; Bonina, Francesco; Puglisi, Giovanni
2017-03-01
Sesamol is a natural phenolic compound extracted from Sesamum indicum seed oil. Sesamol is endowed with several beneficial effects, but its use as a topical agent is strongly compromised by unfavorable chemical-physical properties. Therefore, to improve its characteristics, the aim of the present work was the formulation of nanostructured lipid carriers as drug delivery systems for topical administration of sesamol.Two different nanostructured lipid carrier systems have been produced based on the same solid lipid (Compritol® 888 ATO) but in a mixture with two different kinds of oil phase such as Miglyol® 812 (nanostructured lipid carrier-M) and sesame oil (nanostructured lipid carrier-PLUS). Morphology and dimensional distribution of nanostructured lipid carriers have been characterized by differential scanning calorimetry and photon correlation spectroscopy, respectively. The release pattern of sesamol from nanostructured lipid carriers was evaluated in vitro determining drug percutaneous absorption through excised human skin. Furthermore, an oxygen radical absorbance capacity assay was used to determine their antioxidant activity.From the results obtained, the method used to formulate nanostructured lipid carriers led to a homogeneous dispersion of particles in a nanometric range. Sesamol has been encapsulated efficiently in both nanostructured lipid carriers, with higher encapsulation efficiency values (> 90 %) when sesame oil was used as the oil phase (nanostructured lipid carrier-PLUS). In vitro evidences show that nanostructured lipid carrier dispersions were able to control the rate of sesamol diffusion through the skin, with respect to the reference formulations.Furthermore, the oxygen radical absorbance capacity assay pointed out an interesting and prolonged antioxidant activity of sesamol, especially when vehiculated by nanostructured lipid carrier-PLUS. Georg Thieme Verlag KG Stuttgart · New York.
Color discrimination in carriers of color deficiency.
Hood, S M; Mollon, J D; Purves, L; Jordan, G
2006-09-01
Carriers of X-linked color vision deficiencies have previously been reported to exhibit mild abnormalities of color matching and discrimination. In a sample of 55 carriers of protan and deutan deficiencies and 55 age-matched normal controls, we measured chromatic discrimination along a red-green axis. We found that discrimination was impaired in the case of carriers of deutan deficiencies (which affect the middle-wave-sensitive cones of the retina), but was normal in the case of carriers of protan deficiencies (which affect the long-wave-sensitive cones). We argue that this result can be explained by the difference in the relative numbers of middle- and long-wave cones in heterozygous retinae: the imbalance of the two cone types is predicted to be much greater in the case of the deutan heterozygote than in the case of the protan heterozygote. In future studies it will be necessary to consider separately the two types of heterozygote.
76 FR 56318 - Parts and Accessories Necessary for Safe Operation; Saddle-Mount Braking Requirements
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-13
... a petition for rulemaking from the Automobile Carriers Conference (ACC) of the American Trucking... antilock braking systems. ACC Automobile Carriers Conference. ATA American Trucking Associations. ATC ATC... Carrier Safety Regulations. NATA National Automobile Transporters Association. NPRM notice of proposed...
1993-05-01
nature causes them to raturally form multimolecular, membranous vesicles (or vesicle fragments) (16-19). Like E. coli and salmonella outer membrane...to the varied nature of the peptides to be used, the optimal immunopotentiating regimen or carrier-adjuvant system may not be identical for each toxin...The carriers and adjuvants to be used will include natural proteins (proteosomes or other proteins). We further hypothesize that certain constructo
A study of pyrolysis of oil shale of the Leningrad deposit by solid heat carrier
NASA Astrophysics Data System (ADS)
Gerasimov, G. Ya; Khaskhachikh, V. V.; Potapov, O. P.
2017-11-01
The investigation of the oil shale pyrolysis with a solid heat carrier was carried out using the experimental retorting system that simulates the Galoter industrial process. This system allows verifying both fractional composition of the oil shale and solid heat carrier, and their ratio and temperature. The oil shale of the Leningradsky deposit was used in the work, and quartz sand was used as the solid heat carrier. It is shown that the yield of the shale oil under the pyrolysis with solid heat carrier exceeds by more than 20% the results received in the standard Fisher retort. Using ash as the solid heat carrier results in a decrease in the yield of oil and gas with simultaneous increase in the amount of the solid residue. This is due to the chemical interaction of the acid components of the vapor-gas mixture with the oxides of alkaline-earth metals that are part of the ash.
Unpowered wireless ultrasound tomography system
NASA Astrophysics Data System (ADS)
Zahedi, Farshad; Huang, Haiying
2016-04-01
In this paper, an unpowered wireless ultrasound tomography system is presented. The system consists of two subsystems; the wireless interrogation unit (WIU) and three wireless nodes installed on the structure. Each node is designed to work in generation and sensing modes, but operates at a specific microwave frequency. Wireless transmission of the ultrasound signals between the WIU and the wireless nodes is achieved by converting ultrasound signals to microwave signals and vice versa, using a microwave carrier signal. In the generation mode, both a carrier signal and an ultrasound modulated microwave signal are transmitted to the sensor nodes. Only the node whose operating frequency matches the carrier signal will receive these signals and demodulate them to recover the original ultrasound signal. In the sensing mode, a microwave carrier signal with two different frequency components matching the operating frequencies of the sensor nodes is broadcasted by the WIU. The sensor nodes, in turn, receive the corresponding carrier signals, modulate it with the ultrasound sensing signal, and wirelessly transmit the modulated signal back to the WIU. The demodulation of the sensing signals is performed in the WIU using a digital signal processing. Implementing a software receiver significantly reduces the complexity and the cost of the WIU. A wireless ultrasound tomography system is realized by interchanging the carrier frequencies so that the wireless transducers can take turn to serve as the actuator and sensors.
RF-photonic chirp encoder and compressor for seamless analysis of information flow.
Zalevsky, Zeev; Shemer, Amir; Zach, Shlomo
2008-05-26
In this paper we realize an RF photonic chirp compression system that compresses a continuous stream of incoming RF data (modulated on top of an optical carrier) into a train of temporal short pulses. Each pulse in the train can be separated and treated individually while being sampled by low rate optical switch and without temporal loses of the incoming flow of information. Each such pulse can be filtered and analyzed differently. The main advantage of the proposed system is its capability of being able to handle, seamlessly, high rate information flow with all-optical means and with low rate optical switches.
2008-07-21
CAPE CANAVERAL, Fla. – In the high bay of the Payload Hazardous Servicing Facility at NASA's Kennedy Space Center, workers from NASA's Goddard Space Flight Center remove the protective wrapping from the Flight Support System for the Hubble Space Telescope. The Flight Support System, or FSS, is one of four carriers supporting hardware for space shuttle Atlantis' STS-125 mission to service the telescope. The Super Lightweight Interchangeable Carrier, or SLIC, and the Orbital Replacement Unit Carrier, or ORUC, have also arrived at Kennedy. The Multi-Use Lightweight Equipment carrier will be delivered in early August. The carriers will be prepared for the integration of telescope science instruments, both internal and external replacement components, as well as the flight support equipment to be used by the astronauts during the Hubble servicing mission, targeted for launch Oct. 8. Photo credit: NASA/Jack Pfaller
2008-07-18
CAPE CANAVERAL, Fla. – In the high bay of the Payload Hazardous Servicing Facility at NASA's Kennedy Space Center, the Flight Support System for the Hubble Space Telescope is positioned onto a work platform by workers from NASA's Goddard Space Flight Center. The Flight Support System, or FSS, is one of four carriers supporting hardware for space shuttle Atlantis' STS-125 mission to service the telescope. The Super Lightweight Interchangeable Carrier, or SLIC, and the Orbital Replacement Unit Carrier, or ORUC, have also arrived at Kennedy. The Multi-Use Lightweight Equipment carrier will be delivered in late July. The carriers will be prepared for the integration of telescope science instruments, both internal and external replacement components, as well as the flight support equipment to be used by the astronauts during the Hubble servicing mission, targeted for launch Oct. 8. Photo credit: NASA/Jack Pfaller
2008-07-18
CAPE CANAVERAL, Fla. – In the high bay of the Payload Hazardous Servicing Facility at NASA's Kennedy Space Center, the Flight Support System for the Hubble Space Telescope is positioned onto a work platform by workers from NASA's Goddard Space Flight Center. The Flight Support System, or FSS, is one of four carriers supporting hardware for space shuttle Atlantis' STS-125 mission to service the telescope. The Super Lightweight Interchangeable Carrier, or SLIC, and the Orbital Replacement Unit Carrier, or ORUC, have also arrived at Kennedy. The Multi-Use Lightweight Equipment carrier will be delivered in late July. The carriers will be prepared for the integration of telescope science instruments, both internal and external replacement components, as well as the flight support equipment to be used by the astronauts during the Hubble servicing mission, targeted for launch Oct. 8. Photo credit: NASA/Jack Pfaller
2008-07-18
CAPE CANAVERAL, Fla. – In the high bay of the Payload Hazardous Servicing Facility at NASA's Kennedy Space Center, the Flight Support System for the Hubble Space Telescope is lowered onto a work platform by workers from NASA's Goddard Space Flight Center. The Flight Support System, or FSS, is one of four carriers supporting hardware for space shuttle Atlantis' STS-125 mission to service the telescope. The Super Lightweight Interchangeable Carrier, or SLIC, and the Orbital Replacement Unit Carrier, or ORUC, have also arrived at Kennedy. The Multi-Use Lightweight Equipment carrier will be delivered in late July. The carriers will be prepared for the integration of telescope science instruments, both internal and external replacement components, as well as the flight support equipment to be used by the astronauts during the Hubble servicing mission, targeted for launch Oct. 8. Photo credit: NASA/Jack Pfaller
2008-07-18
CAPE CANAVERAL, Fla. – In the high bay of the Payload Hazardous Servicing Facility at NASA's Kennedy Space Center, the Flight Support System for the Hubble Space Telescope is lifted from its transportation canister by workers from NASA's Goddard Space Flight Center. The Flight Support System, or FSS, is one of four carriers supporting hardware for space shuttle Atlantis' STS-125 mission to service the telescope. The Super Lightweight Interchangeable Carrier, or SLIC, and the Orbital Replacement Unit Carrier, or ORUC, have also arrived at Kennedy. The Multi-Use Lightweight Equipment carrier will be delivered in late July. The carriers will be prepared for the integration of telescope science instruments, both internal and external replacement components, as well as the flight support equipment to be used by the astronauts during the Hubble servicing mission, targeted for launch Oct. 8. Photo credit: NASA/Jack Pfaller
2008-07-18
CAPE CANAVERAL, Fla. – In the high bay of the Payload Hazardous Servicing Facility at NASA's Kennedy Space Center, workers from NASA's Goddard Space Flight Center prepare to lift the Flight Support System for the Hubble Space Telescope from its transportation canister. The Flight Support System, or FSS, is one of four carriers supporting hardware for space shuttle Atlantis' STS-125 mission to service the telescope. The Super Lightweight Interchangeable Carrier, or SLIC, and the Orbital Replacement Unit Carrier, or ORUC, have also arrived at Kennedy. The Multi-Use Lightweight Equipment carrier will be delivered in late July. The carriers will be prepared for the integration of telescope science instruments, both internal and external replacement components, as well as the flight support equipment to be used by the astronauts during the Hubble servicing mission, targeted for launch Oct. 8. Photo credit: NASA/Jack Pfaller
2008-07-18
CAPE CANAVERAL, Fla. – In the high bay of the Payload Hazardous Servicing Facility at NASA's Kennedy Space Center, workers from NASA's Goddard Space Flight Center begin to lift the Flight Support System for the Hubble Space Telescope from its transportation canister. The Flight Support System, or FSS, is one of four carriers supporting hardware for space shuttle Atlantis' STS-125 mission to service the telescope. The Super Lightweight Interchangeable Carrier, or SLIC, and the Orbital Replacement Unit Carrier, or ORUC, have also arrived at Kennedy. The Multi-Use Lightweight Equipment carrier will be delivered in late July. The carriers will be prepared for the integration of telescope science instruments, both internal and external replacement components, as well as the flight support equipment to be used by the astronauts during the Hubble servicing mission, targeted for launch Oct. 8. Photo credit: NASA/Jack Pfaller
2008-07-18
CAPE CANAVERAL, Fla. – In the high bay of the Payload Hazardous Servicing Facility at NASA's Kennedy Space Center, the Flight Support System for the Hubble Space Telescope is lowered onto a work platform by workers from NASA's Goddard Space Flight Center. The Flight Support System, or FSS, is one of four carriers supporting hardware for space shuttle Atlantis' STS-125 mission to service the telescope. The Super Lightweight Interchangeable Carrier, or SLIC, and the Orbital Replacement Unit Carrier, or ORUC, have also arrived at Kennedy. The Multi-Use Lightweight Equipment carrier will be delivered in late July. The carriers will be prepared for the integration of telescope science instruments, both internal and external replacement components, as well as the flight support equipment to be used by the astronauts during the Hubble servicing mission, targeted for launch Oct. 8. Photo credit: NASA/Jack Pfaller
2008-07-18
CAPE CANAVERAL, Fla. – In the high bay of the Payload Hazardous Servicing Facility at NASA's Kennedy Space Center, the Flight Support System for the Hubble Space Telescope is positioned onto a work platform by workers from NASA's Goddard Space Flight Center. The Flight Support System, or FSS, is one of four carriers supporting hardware for space shuttle Atlantis' STS-125 mission to service the telescope. The Super Lightweight Interchangeable Carrier, or SLIC, and the Orbital Replacement Unit Carrier, or ORUC, have also arrived at Kennedy. The Multi-Use Lightweight Equipment carrier will be delivered in late July. The carriers will be prepared for the integration of telescope science instruments, both internal and external replacement components, as well as the flight support equipment to be used by the astronauts during the Hubble servicing mission, targeted for launch Oct. 8. Photo credit: NASA/Jack Pfaller
2008-07-21
CAPE CANAVERAL, Fla. – In the high bay of the Payload Hazardous Servicing Facility at NASA's Kennedy Space Center, workers from NASA's Goddard Space Flight Center remove the protective wrapping from the Flight Support System for the Hubble Space Telescope. The Flight Support System, or FSS, is one of four carriers supporting hardware for space shuttle Atlantis' STS-125 mission to service the telescope. The Super Lightweight Interchangeable Carrier, or SLIC, and the Orbital Replacement Unit Carrier, or ORUC, have also arrived at Kennedy. The Multi-Use Lightweight Equipment carrier will be delivered in early August. The carriers will be prepared for the integration of telescope science instruments, both internal and external replacement components, as well as the flight support equipment to be used by the astronauts during the Hubble servicing mission, targeted for launch Oct. 8. Photo credit: NASA/Jack Pfaller
2008-07-18
CAPE CANAVERAL, Fla. – In the high bay of the Payload Hazardous Servicing Facility at NASA's Kennedy Space Center, the Flight Support System for the Hubble Space Telescope is lifted from its transportation canister under the supervision of workers from NASA's Goddard Space Flight Center. The Flight Support System, or FSS, is one of four carriers supporting hardware for space shuttle Atlantis' STS-125 mission to service the telescope. The Super Lightweight Interchangeable Carrier, or SLIC, and the Orbital Replacement Unit Carrier, or ORUC, have also arrived at Kennedy. The Multi-Use Lightweight Equipment carrier will be delivered in late July. The carriers will be prepared for the integration of telescope science instruments, both internal and external replacement components, as well as the flight support equipment to be used by the astronauts during the Hubble servicing mission, targeted for launch Oct. 8. Photo credit: NASA/Jack Pfaller
2008-07-18
CAPE CANAVERAL, Fla. – In the high bay of the Payload Hazardous Servicing Facility at NASA's Kennedy Space Center, the Flight Support System for the Hubble Space Telescope is lifted from its transportation canister under the supervision of workers from NASA's Goddard Space Flight Center. The Flight Support System, or FSS, is one of four carriers supporting hardware for space shuttle Atlantis' STS-125 mission to service the telescope. The Super Lightweight Interchangeable Carrier, or SLIC, and the Orbital Replacement Unit Carrier, or ORUC, have also arrived at Kennedy. The Multi-Use Lightweight Equipment carrier will be delivered in late July. The carriers will be prepared for the integration of telescope science instruments, both internal and external replacement components, as well as the flight support equipment to be used by the astronauts during the Hubble servicing mission, targeted for launch Oct. 8. Photo credit: NASA/Jack Pfaller
Characterization of n-Type and p-Type Long-Wave InAs/InAsSb Superlattices
NASA Astrophysics Data System (ADS)
Brown, A. E.; Baril, N.; Zuo, D.; Almeida, L. A.; Arias, J.; Bandara, S.
2017-09-01
The influence of dopant concentration on both in-plane mobility and minority carrier lifetime in long-wave infrared InAs/InAsSb superlattices (SLs) was investigated. Unintentially doped ( n-type) and various concentrations of Be-doped ( p-type) SLs were characterized using variable-field Hall and photoconductive decay techniques. Minority carrier lifetimes in p-type InAs/InAsSb SLs are observed to decrease with increasing carrier concentration, with the longest lifetime at 77 K determined to be 437 ns, corresponding to a measured carrier concentration of p 0 = 4.1 × 1015 cm-3. Variable-field Hall technique enabled the extraction of in-plane hole, electron, and surface electron transport properties as a function of temperature. In-plane hole mobility is not observed to change with doping level and increases with reducing temperature, reaching a maximum at the lowest temperature measured of 30 K. An activation energy of the Be-dopant is determined to be 3.5 meV from Arrhenius analysis of hole concentration. Minority carrier electrons populations are suppressed at the highest Be-doping levels, but mobility and concentration values are resolved in lower-doped samples. An average surface electron conductivity of 3.54 × 10-4 S at 30 K is determined from the analysis of p-type samples. Effects of passivation treatments on surface conductivity will be presented.
NASA Astrophysics Data System (ADS)
Zhao, Lei; Xu, Hengying; Bai, Chenglin
2018-03-01
In orthogonal frequency division multiplexing (OFDM)-based elastic optical networking (EON), it is imperative to identify unknown parameters of OFDM-based EON signals quickly, intelligently and robustly. Because the number of sub-carriers determines the size of the sub-carriers spacing and then affects the symbol period of the OFDM and the anti-dispersion capability of the system, the identification of the number of sub-carriers has a profound effect on the identification of other key parameters of the system. In this paper, we proposed a method of number identification for sub-carriers of OFDM-based EON signals with help of high-order cyclic cumulant. The specific fourth-order cyclic cumulant exists only at the location of its sub-carriers frequencies. So the identification of the number of sub-carriers can be implemented by detecting the cyclic-frequencies. The proposed scheme in our study can be divided into three sub-stages, i.e. estimating the spectral range, calculating the high-order cyclic cumulant and identifying the number of sub-carriers. When the optical signal-to-noise ratios (OSNR) varied from 16dB to 22dB, the number of sub-carriers (64-512) was successfully identified in the experiment, and from the statistical point of view, the average identification absolute accuracy (IAAs) exceeded 94%.
Communication about carrier testing within hemophilia A families.
Sorenson, James R; Jennings-Grant, Tracey; Newman, Jamie
2003-05-15
Genetic diseases are family diseases. Although there is considerable research on how individuals decide to have genetic testing and their individual reactions to testing, there is limited research on the familial context of genetic testing. In the present study, we focus on three aspects of the family context of genetic testing for hemophilia A carrier status among women at risk to be carriers. We look at the extent to which there was discussion of carrier testing for hemophilia before we offered DNA-based carrier testing to these at-risk women; with which family members these tested women communicated the results of their carrier testing; and concerns these women had about communicating their carrier test results with relatives, including their children. Data suggest that members of families with hemophilia discussed carrier testing prior to study participation, that the communication of testing information within families was selective, not universal, largely following gender lines for this X-linked disorder, and that there was limited concern about communicating carrier status information to children and other relatives. These data reinforce observations that families are social systems, and within these systems information is selectively communicated. A more complete understanding of how families communicate genetic test information will enable providers to develop more effective means of assisting individuals in handling the familial communication aspects of genetic testing. Copyright 2002 Wiley-Liss, Inc.
A simplified method for determining heat of combustion of natural gas
NASA Technical Reports Server (NTRS)
Singh, Jag J.; Chegini, Hoshang; Mall, Gerald H.
1987-01-01
A simplified technique for determination of the heat of combustion of natural gas has been developed. It is a variation of the previously developed technique wherein the carrier air, in which the test sample was burnt, was oxygen enriched to adjust the mole fraction of oxygen in the combustion product gases up to that in the carrier air. The new technique eliminates the need for oxygen enrichment of the experimental mixtures and natural gas samples and has been found to predict their heats of combustion to an uncertainty of the order of 1 percent.
DOT National Transportation Integrated Search
2007-10-02
The objective was to evaluate economic justifications for motor carriers to participate in CVISN deployment. CVISN (Commercial Vehicle Information Systems and Networks) includes: interstate credentials administration (registration and permitting), el...
76 FR 61279 - Communications Common Carriers, Reporting and Recordkeeping Requirements, Telephone...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-04
... FEDERAL COMMUNICATIONS COMMISSION 47 CFR Parts 32, 52, 61, 64, and 69 Communications Common Carriers, Reporting and Recordkeeping Requirements, Telephone, Telecommunications, Uniform System of..., Telecommunications, Uniform system of accounts. Federal Communications Commission. Marlene H. Dortch, Secretary. [FR...
Qu, Ying; Chu, BingYang; Shi, Kun; Peng, JinRong; Qian, ZhiYong
2017-12-01
Polymeric micelles have presented superior delivery properties for poorly water-soluble chemotherapeutic agents. However, it remains discouraging that there may be some additional short or long-term toxicities caused by the metabolites of high quantities of carriers. If carriers had simultaneous therapeutic effects with the drug, these issues would not be a concern. For this, carriers not only simply act as drug carriers, but also exert an intrinsic therapeutic effect as a therapeutic agent. The functional micellar carriers would be beneficial to maximize the anticancer effect, overcome the drug resistance and reduce the systemic toxicity. In this review, we aim to summarize the recent progress on the development of functional micellar carriers with intrinsic anticancer activities for the delivery of anticancer drugs. This review focuses on the design strategies, properties of carriers and the drug loading behavior. In addition, the combinational therapeutic effects between carriers and chemotherapeutic agents are also discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ke, Wen-Cheng, E-mail: wcke@mail.ntust.edu.tw; Yang, Cheng-Yi; Lee, Fang-Wei
2015-10-21
This study developed an Ohmic contact formation method for a ZnO:Al (AZO) transparent conductive layer on p-GaN films involving the introduction of an indium oxynitride (InON) nanodot interlayer. An antisurfactant pretreatment was used to grow InON nanodots on p-GaN films in a RF magnetron sputtering system. A low specific contact resistance of 1.12 × 10{sup −4} Ω cm{sup 2} was achieved for a sample annealed at 500 °C for 30 s in nitrogen ambient and embedded with an InON nanodot interlayer with a nanodot density of 6.5 × 10{sup 8} cm{sup −2}. By contrast, a sample annealed in oxygen ambient exhibited non-Ohmic behavior. X-ray photoemission spectroscopy resultsmore » showed that the oxygen vacancy (V{sub o}) in the InON nanodots played a crucial role in carrier transport. The fitting I–V characteristic curves indicated that the hopping mechanism with an activation energy of 31.6 meV and trap site spacing of 1.1 nm dominated the carrier transport in the AZO/InON nanodot/p-GaN sample. Because of the high density of donor-like oxygen vacancy defects at the InON nanodot/p-GaN interface, positive charges from the underlying p-GaN films were absorbed at the interface. This led to positive charge accumulation, creating a narrow depletion layer; therefore, carriers from the AZO layer passed through InON nanodots by hopping transport, and subsequently tunneling through the interface to enter the p-GaN films. Thus, AZO Ohmic contact can be formed on p-GaN films by embedding an InON nanodot interlayer to facilitate trap-assisted tunneling.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-05
...-0392] Proposed Enhancements to the Motor Carrier Safety Measurement System (SMS) Public Web Site AGENCY... on the Agency's Safety Measurement System (SMS) public Web site. FMCSA first announced the... public Web site that are the direct result of feedback from stakeholders regarding the information...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-02
...-0457] Motor Carrier Management Information System (MCMIS) Changes to Improve Uniformity in the... Management Information System (MCMIS) to allow the Agency to upload the results of associated adjudicated... information concerning a citation associated with a violation that was dismissed or resulted in a finding of...
Comparison of CDMA and FDMA for the MobileStar(sm) system
NASA Technical Reports Server (NTRS)
Jacobs, I. M.; Gilhousen, K. S.; Weaver, L. A.; Renshaw, K.; Murphy, T.
1988-01-01
Spread-spectrum code division multiple access (CDMA) and single channel per carrier frequency division multiple access (FDMA) systems are compared for spectrum efficiency. CDMA is shown to have greater maximum throughput than FDMA for the MobileStar(sm) system which uses digital voice activated carriers and directive circularly polarized satellite antennas.
Canier, Lydie; Khim, Nimol; Kim, Saorin; Eam, Rotha; Khean, Chanra; Loch, Kaknika; Ken, Malen; Pannus, Pieter; Bosman, Philippe; Stassijns, Jorgen; Nackers, Fabienne; Alipon, SweetC; Char, Meng Chuor; Chea, Nguon; Etienne, William; De Smet, Martin; Kindermans, Jean-Marie; Ménard, Didier
2015-01-01
In the context of malaria elimination, novel strategies for detecting very low malaria parasite densities in asymptomatic individuals are needed. One of the major limitations of the malaria parasite detection methods is the volume of blood samples being analyzed. The objective of the study was to compare the diagnostic accuracy of a malaria polymerase chain reaction assay, from dried blood spots (DBS, 5 μL) and different volumes of venous blood (50 μL, 200 μL, and 1 mL). The limit of detection of the polymerase chain reaction assay, using calibrated Plasmodium falciparum blood dilutions, showed that venous blood samples (50 μL, 200 μL, 1 mL) combined with Qiagen extraction methods gave a similar threshold of 100 parasites/mL, ∼100-fold lower than 5 μL DBS/Instagene method. On a set of 521 field samples, collected in two different transmission areas in northern Cambodia, no significant difference in the proportion of parasite carriers, regardless of the methods used was found. The 5 μL DBS method missed 27% of the samples detected by the 1 mL venous blood method, but most of the missed parasites carriers were infected by Plasmodium vivax (84%). The remaining missed P. falciparum parasite carriers (N = 3) were only detected in high-transmission areas. PMID:25561570
Hydrogasification reactor and method of operating same
Hobbs, Raymond; Karner, Donald; Sun, Xiaolei; Boyle, John; Noguchi, Fuyuki
2013-09-10
The present invention provides a system and method for evaluating effects of process parameters on hydrogasification processes. The system includes a hydrogasification reactor, a pressurized feed system, a hopper system, a hydrogen gas source, and a carrier gas source. Pressurized carbonaceous material, such as coal, is fed to the reactor using the carrier gas and reacted with hydrogen to produce natural gas.
DOT National Transportation Integrated Search
2016-11-01
The Federal Motor Carrier Safety Administration (FMCSA), in cooperation with the John A. Volpe National Transportation Systems Center (Volpe), has developed a quantitative model to measure the effectiveness of motor carrier interventions in terms of ...
DOT National Transportation Integrated Search
2018-04-01
The Federal Motor Carrier Safety Administration (FMCSA), in cooperation with the John A. Volpe National Transportation Systems Center (Volpe), has developed a quantitative model to measure the effectiveness of motor carrier interventions in terms of ...
DOT National Transportation Integrated Search
2017-04-01
The Federal Motor Carrier Safety Administration (FMCSA), in cooperation with the John A. Volpe National Transportation Systems Center (Volpe), has developed a quantitative model to measure the effectiveness of motor carrier interventions in terms of ...
DOT National Transportation Integrated Search
2015-01-01
The Federal Motor Carrier Safety Administration (FMCSA), in cooperation with the John A. Volpe National : Transportation Systems Center (Volpe), has developed a quantitative model to measure the effectiveness of motor : carrier interventions in terms...
DOT National Transportation Integrated Search
2017-04-01
The Federal Motor Carrier Safety Administration (FMCSA), in cooperation with the John A. Volpe National Transportation Systems Center (Volpe), has developed a quantitative model to measure the effectiveness of motor carrier interventions in terms of ...
Minority carrier diffusion lengths and absorption coefficients in silicon sheet material
NASA Technical Reports Server (NTRS)
Dumas, K. A.; Swimm, R. T.
1980-01-01
Most of the methods which have been developed for the measurement of the minority carrier diffusion length of silicon wafers require that the material have either a Schottky or an ohmic contact. The surface photovoltage (SPV) technique is an exception. The SPV technique could, therefore, become a valuable diagnostic tool in connection with current efforts to develop low-cost processes for the production of solar cells. The technique depends on a knowledge of the optical absorption coefficient. The considered investigation is concerned with a reevaluation of the absorption coefficient as a function of silicon processing. A comparison of absorption coefficient values showed these values to be relatively consistent from sample to sample, and independent of the sample growth method.
Optical spectroscopy of nanoscale and heterostructured oxides
NASA Astrophysics Data System (ADS)
Senty, Tess R.
Through careful analysis of a material's properties, devices are continually getting smaller, faster and more efficient each day. Without a complete scientific understanding of material properties, devices cannot continue to improve. This dissertation uses optical spectroscopy techniques to understand light-matter interactions in several oxide materials with promising uses mainly in light harvesting applications. Linear absorption, photoluminescence and transient absorption spectroscopy are primarily used on europium doped yttrium vanadate nanoparticles, copper gallium oxide delafossites doped with iron, and cadmium selenide quantum dots attached to titanium dioxide nanoparticles. Europium doped yttrium vanadate nanoparticles have promising applications for linking to biomolecules. Using Fourier-transform infrared spectroscopy, it was shown that organic ligands (benzoic acid, 3-nitro 4-chloro-benzoic acid and 3,4-dihydroxybenzoic acid) can be attached to the surface of these molecules using metal-carboxylate coordination. Photoluminescence spectroscopy display little difference in the position of the dominant photoluminescence peaks between samples with different organic ligands although there is a strong decrease in their intensity when 3,4-dihydroxybenzoic acid is attached. It is shown that this strong quenching is due to the presence of high-frequency hydroxide vibrational modes within the organic linker. Ultraviolet/visible linear absorption measurements on delafossites display that by doping copper gallium oxide with iron allows for the previously forbidden fundamental gap transition to be accessed. Using tauc plots, it is shown that doping with iron lowers the bandgap from 2.8 eV for pure copper gallium oxide, to 1.7 eV for samples with 1 -- 5% iron doping. Using terahertz transient absorption spectroscopy measurements, it was also determined that doping with iron reduces the charge mobility of the pure delafossite samples. A comparison of cadmium selenide quantum dots, both with and without capping ligands, attached to titanium dioxide nanoparticles is performed using a new transient absorption analysis technique. Multiple exponential fit models were applied to the system and compared with the new inversion analysis technique. It is shown how the new inversion analysis can map out the charge carrier dynamics, providing carrier recombination rates and lifetimes as a function of carrier concentration, where the multiple exponential fit technique is not dependent on the carrier concentration. With the inversion analysis technique it is shown that capping ligands allow for increased charge transfer due to traps being passivated on the quantum dot surface.
Distribution of Monochrome Screen Luminance in the CTOL Visual Technology Research Simulator.
1980-11-01
runway lines 3.8 4.2 8. Carrier runway 2.5 3.5 9. FLOLS* Meatball ** 2.0 2.4 10. FLOLS Background 0.68 1.3 *Fresnal Lens Optical Landing System...Standard U.S. Navy carrier optical landing device). ** Meatball is the light source of the FLOLS which the pilot uses for glideslope information in a carrier...LANDING DISPLAY FOV (Foot Lamberts) 1. Carrier Deck Runway Lighting 1.5 2. Carrier Runway Area 0.048 3. FLOLS Meatball 0.6 Figure 5 also shows the
NASA Astrophysics Data System (ADS)
Müller, Jens; Hartmann, Benedikt; Sasaki, Takahiko
2017-12-01
The unique possibilities of fine-tuning their physical properties in the vicinity of the Mott metal-insulator transition make the quasi-two-dimensional organic charge-transfer salts ?-(BEDT-TTF)?X unprecedented model systems for studying the fundamentals of electron-electron correlations and the coupling between charge, spin and lattice degrees of freedom in reduced dimensions. The critical properties and the universality class of the Mott transition, however, are controversially debated for these materials, and information on the low-frequency dynamical properties of the correlated electrons is rather limited. By introducing fluctuation (noise) spectroscopy as a powerful new tool for studying the slow dynamics of charge carriers, in the past years we have been able to extract spectroscopic information on the coupling of charge carriers to the vibrational degrees of freedom of the crystal lattice. This is related to a glassy freezing of the BEDT-TTF molecules' ethylene end-group (EEG) rotations at elevated temperatures, which (i) results in a small amount of (intrinsic) disorder and (ii) crucially influences the ratio of bandwidth to on-site Coulomb repulsion (W / U) and therefore the samples' position in the phase diagram, i.e. the electronic ground state. The low-frequency resistance fluctuations show a dramatic enhancement and divergent behaviour when tuning the sample close to the critical point of the Mott transition, accompanied by a strong shift of spectral weight to low frequencies and the onset of non-Gaussian behaviour. This indicates the critical slowing down of the order-parameter (doublon density) fluctuations and suggests a collective dynamics of the correlated electrons. In order to enable detailed investigations of this hypothesis in future experiments, by exploiting the structural EEG relaxation, a 'warming cycle' protocol can be established that allows for fine-tuning the sample across the Mott transition and therefore precisely accessing the finite-temperature critical endpoint. We 'calibrate' this procedure by a comparison to pressure-tuning experiments on the same sample. This method will allow to map out the region of ergodicity breaking around the critical endpoint and its dependence on disorder.
Carrier lifetimes in polar InGaN-based LEDs
NASA Astrophysics Data System (ADS)
Wang, Lai; Jin, Jie; Hao, Zhibiao; Luo, Yi
2018-02-01
Measurement of carrier lifetime is very important to understand the physics in light-emitting diodes (LEDs), as it builds a link between carrier concentration and excitation power or current density. In this paper, we present our study on optical and electrical characterizations on carrier lifetimes in polar InGaN-based LEDs. First, a carrier rate equation model is proposed to explain the non-exponential nature of time-resolved photoluminescence (TRPL) decay curves, wherein exciton recombination is replaced by bimolecular recombination, considering the influence of polarization field on electron-hole pairs. Then, nonradiative recombination and radiative recombination coefficients can be deduced from fitting and used to calculate the radiative recombination efficiency. By comparing with the temperature-dependent photoluminescence (TDPL) and power-dependent photoluminescence (PDPL), it is found these three methods provide the consistent results. Second, differential carrier lifetimes depending on injection current are measured in commercial near-ultraviolet (NUV), blue and green LEDs. It is found that carrier lifetime is longer in green one and shorter in NUV one, which is attributed to the influence of polarization-induced quantum confined Stark effect (QCSE). This result implies the carrier density is higher in green LED while lower NUV LED, even the injection current is the same. By ignoring Auger recombination and fitting the efficiency-current and carrier lifetime-current curves simultaneously, the dependence of injection efficiency on carrier concentration in different LED samples are plotted. The NUV LED, which has the shallowest InGaN quantum well, actually exhibits the most serious efficiency droop versus carrier concentration. Then, the approaches to overcome the efficiency droop are discussed.
Micro and Nano Material Carriers for Immunomodulation
Bracho-Sanchez, Evelyn; Xia, Chang Qing; Clare-Salzler, Michael J.; Keselowsky, Benjamin G.
2016-01-01
Modulation of the immune system through the use of micro and nano carriers offers opportunities in transplant tolerance, autoimmunity, infectious disease and cancer. In particular, polymeric, lipid and inorganic materials have been used as carriers of proteins, nucleic acids, and small drug molecules to direct the immune system toward either suppressive or stimulatory states. Current technologies have focused on the use of particulates or scaffolds, the modulation of materials properties, and the delivery of biologics or small drug molecules to achieve a desired response. Discussed are relevant immunology concepts, the types of biomaterial-carriers used for immunomodulation highlighting their benefits and drawbacks, the material properties influencing immune responses, and recent examples in the field of transplant tolerance. PMID:27214679
CANISTER TRANSFER SYSTEM DESCRIPTION DOCUMENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
B. Gorpani
2000-06-23
The Canister Transfer System receives transportation casks containing large and small disposable canisters, unloads the canisters from the casks, stores the canisters as required, loads them into disposal containers (DCs), and prepares the empty casks for re-shipment. Cask unloading begins with cask inspection, sampling, and lid bolt removal operations. The cask lids are removed and the canisters are unloaded. Small canisters are loaded directly into a DC, or are stored until enough canisters are available to fill a DC. Large canisters are loaded directly into a DC. Transportation casks and related components are decontaminated as required, and empty casks aremore » prepared for re-shipment. One independent, remotely operated canister transfer line is provided in the Waste Handling Building System. The canister transfer line consists of a Cask Transport System, Cask Preparation System, Canister Handling System, Disposal Container Transport System, an off-normal canister handling cell with a transfer tunnel connecting the two cells, and Control and Tracking System. The Canister Transfer System operating sequence begins with moving transportation casks to the cask preparation area with the Cask Transport System. The Cask Preparation System prepares the cask for unloading and consists of cask preparation manipulator, cask inspection and sampling equipment, and decontamination equipment. The Canister Handling System unloads the canister(s) and places them into a DC. Handling equipment consists of a bridge crane hoist, DC loading manipulator, lifting fixtures, and small canister staging racks. Once the cask has been unloaded, the Cask Preparation System decontaminates the cask exterior and returns it to the Carrier/Cask Handling System via the Cask Transport System. After the DC is fully loaded, the Disposal Container Transport System moves the DC to the Disposal Container Handling System for welding. To handle off-normal canisters, a separate off-normal canister handling cell is located adjacent to the canister transfer cell and is interconnected to the transfer cell by means of the off-normal canister transfer tunnel. All canister transfer operations are controlled by the Control and Tracking System. The system interfaces with the Carrier/Cask Handling System for incoming and outgoing transportation casks. The system also interfaces with the Disposal Container Handling System, which prepares the DC for loading and subsequently seals the loaded DC. The system support interfaces are the Waste Handling Building System and other internal Waste Handling Building (WHB) support systems.« less
The use of interleaving for reducing radio loss in trellis-coded modulation systems
NASA Technical Reports Server (NTRS)
Divsalar, D.; Simon, M. K.
1989-01-01
It is demonstrated how the use of interleaving/deinterleaving in trellis-coded modulation (TCM) systems can reduce the signal-to-noise ratio loss due to imperfect carrier demodulation references. Both the discrete carrier (phase-locked loop) and suppressed carrier (Costas loop) cases are considered and the differences between the two are clearly demonstrated by numerical results. These results are of great importance for future communication links to the Deep Space Network (DSN), especially from high Earth orbiters, which may be bandwidth limited.
Smith, Stephen F [Loudon, TN; Moore, James A [Powell, TN
2011-02-01
Systems and methods are described for carrier phase synchronization for improved AM and TV broadcast reception. A method includes synchronizing the phase of a carrier frequency of a broadcast signal with the phase of a remote reference frequency. An apparatus includes a receiver to detect the phase of a reference signal; a phase comparator coupled to the reference signal-phase receiver; a voltage controlled oscillator coupled to the phase comparator; and a phase-controlled radio frequency output coupled to the voltage controlled oscillator.
Zhang, Lijia; Liu, Bo; Xin, Xiangjun
2015-06-15
A secure enhanced coherent optical multi-carrier system based on Stokes vector scrambling is proposed and experimentally demonstrated. The optical signal with four-dimensional (4D) modulation space has been scrambled intra- and inter-subcarriers, where a multi-layer logistic map is adopted as the chaotic model. An experiment with 61.71-Gb/s encrypted multi-carrier signal is successfully demonstrated with the proposed method. The results indicate a promising solution for the physical secure optical communication.
Supercritical fuel injection system
NASA Technical Reports Server (NTRS)
Marek, C. J.; Cooper, L. P. (Inventor)
1980-01-01
a fuel injection system for gas turbines is described including a pair of high pressure pumps. The pumps provide fuel and a carrier fluid such as air at pressures above the critical pressure of the fuel. A supercritical mixing chamber mixes the fuel and carrier fluid and the mixture is sprayed into a combustion chamber. The use of fuel and a carrier fluid at supercritical pressures promotes rapid mixing of the fuel in the combustion chamber so as to reduce the formation of pollutants and promote cleaner burning.
Tungsten-188/carrier-free rhenium-188 perrhenic acid generator system
Knapp, Jr., Furn F.; Lisic, Edward C.; Mirzadeh, Saed; Callahan, Alvin P.
1993-01-01
A generator system for providing a carrier-free radioisotope in the form of an acid comprises a chromatography column in tandem fluid connection with an ion exchange column, the chromatography column containing a charge of a radioactive parent isotope. The chromatography column, charged with a parent isotope, is eluted with an alkali metal salt solution to generate the radioisotope in the form of an intermediate solution, which is passed through the ion-exchange column to convert the radioisotope to a carrier-free acid form.
Tungsten-188/carrier-free rhenium-188 perrhenic acid generator system
Knapp, F.F. Jr.; Lisic, E.C.; Mirzadeh, S.; Callahan, A.P.
1993-02-16
A generator system for providing a carrier-free radioisotope in the form of an acid comprises a chromatography column in tandem fluid connection with an ion exchange column, the chromatography column containing a charge of a radioactive parent isotope. The chromatography column, charged with a parent isotope, is eluted with an alkali metal salt solution to generate the radioisotope in the form of an intermediate solution, which is passed through the ion-exchange column to convert the radioisotope to a carrier-free acid form.
Tungsten-188/carrier-free rhenium-188 perrhenic acid generator system
Knapp, Jr., Furn F.; Lisic, Edward C.; Mirzadeh, Saed; Callahan, Alvin P.
1994-01-01
A generator system for providing a carrier-free radioisotope in the form of an acid comprises a chromatography column in tandem fluid connection with an ion exchange column, the chromatography column containing a charge of a radioactive parent isotope. The chromatography column, charged with a parent isotope, is eluted with an alkali metal salt solution to generate the radioisotope in the form of an intermediate solution, which is passed through the ion-exchange column to convert the radioisotope to a carrier-free acid form.
48 CFR 1615.470 - Carrier investment of FEHB funds.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Carrier investment of FEHB funds. 1615.470 Section 1615.470 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION CONTRACTING METHODS AND CONTRACT TYPES...
48 CFR 1632.170 - Recurring premium payments to carriers.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Recurring premium payments to carriers. 1632.170 Section 1632.170 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL CONTRACTING REQUIREMENTS CONTRACT...
48 CFR 1609.7101-2 - Community-rated carrier performance factors.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Community-rated carrier performance factors. 1609.7101-2 Section 1609.7101-2 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION ACQUISITION PLANNING...
48 CFR 1615.470 - Carrier investment of FEHB funds.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Carrier investment of FEHB funds. 1615.470 Section 1615.470 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION CONTRACTING METHODS AND CONTRACT TYPES...
48 CFR 1609.7101-2 - Community-rated carrier performance factors.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Community-rated carrier performance factors. 1609.7101-2 Section 1609.7101-2 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION ACQUISITION PLANNING...
48 CFR 1615.470 - Carrier investment of FEHB funds.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Carrier investment of FEHB funds. 1615.470 Section 1615.470 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION CONTRACTING METHODS AND CONTRACT TYPES...
48 CFR 1632.170 - Recurring premium payments to carriers.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Recurring premium payments to carriers. 1632.170 Section 1632.170 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL CONTRACTING REQUIREMENTS CONTRACT...
48 CFR 1609.7101-2 - Community-rated carrier performance factors.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Community-rated carrier performance factors. 1609.7101-2 Section 1609.7101-2 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION ACQUISITION PLANNING...
Garris, Rebekah L.; Johnston, Steven; Li, Jian V.; ...
2017-08-31
In a previous study, we reported on Cu(In,Ga)Se2-based (CIGS) solar cell samples collected from different research laboratories and industrial companies with the purpose of understanding the range of CIGS materials that can lead to high-quality and high-efficiency solar panels. Here, we report on electrical measurements of those same samples. Electron-beam induced current and time-resolved photoluminescence (TRPL) gave insights about the collection probability and the lifetime of carriers generated in each absorber. Capacitance and drive-level capacitance profiling revealed nonuniformity in carrier-density profiles. Admittance spectroscopy revealed small activation energies (= 0.03 eV) indicative of the inversion strength, larger activation energies (> 0.1more » eV) reflective of thermal activation of absorber conductivity and a deeper defect level. Deep-level transient spectroscopy (DLTS) probed deep hole-trapping defects and showed that all samples in this study had a majority-carrier defect with activation energy between 0.3 eV and 0.9 eV. Optical-DLTS revealed deep electron-trapping defects in several of the CIGS samples. This work focused on revealing similarities and differences between high-quality CIGS solar cells made with various structures and fabrication techniques.« less