Sample records for sample collection laboratory

  1. Investigation of differences between field and laboratory pH measurements of national atmospheric deposition program/national trends network precipitation samples

    USGS Publications Warehouse

    Latysh, N.; Gordon, J.

    2004-01-01

    A study was undertaken to investigate differences between laboratory and field pH measurements for precipitation samples collected from 135 weekly precipitation-monitoring sites in the National Trends Network from 12/30/1986 to 12/28/1999. Differences in pH between field and laboratory measurements occurred for 96% of samples collected during this time period. Differences between the two measurements were evaluated for precipitation samples collected before and after January 1994, when modifications to sample-handling protocol and elimination of the contaminating bucket o-ring used in sample shipment occurred. Median hydrogen-ion and pH differences between field and laboratory measurements declined from 3.9 ??eq L-1 or 0.10 pH units before the 1994 protocol change to 1.4 ??eq L-1 or 0.04 pH units after the 1994 protocol change. Hydrogen-ion differences between field and laboratory measurements had a high correlation with the sample pH determined in the field. The largest pH differences between the two measurements occurred for high-pH samples (>5.6), typical of precipitation collected in Western United States; however low- pH samples (<5.0) displayed the highest variability in hydrogen-ion differences between field and laboratory analyses. Properly screened field pH measurements are a useful alternative to laboratory pH values for trend analysis, particularly before 1994 when laboratory pH values were influenced by sample-collection equipment.

  2. Fetal Tissue Procurement for Karyotype Analysis: Clinician or Pathologist - Which is Better?

    PubMed

    Conant, Joanna L; Tang, Mary E; Waters, Brenda L

    2016-01-01

    Chromosomal abnormalities are detected in up to 13% of stillbirths and over 20% of those with developmental anomalies. These estimates may be low since up to 50% of samples fail to achieve a result due to microbial overgrowth or nonviability. Tissue for cytogenetics can be procured at bedside by the clinician or by the pathologist in the laboratory. With clinical collection, tissue is placed into culture media immediately, increasing chances of growth. However, collection competes for attention with other activities, which may result in microbial overgrowth or selection of maternal rather than fetal tissue. Laboratory procurement occurs in a controlled environment using sterile technique, but delay in collection may decrease viability. Our goal was to determine which collection method yields better results. We reviewed cases from 2007-2013 that had two samples submitted for cytogenetics, one from the clinician and one from the pathologist. Specimen source, delivery, collection, and culture setup times, harvest date, cell growth, microbial overgrowth, maternal contamination and final result were obtained from medical records and cytogenetic culture sheets. There was no difference in growth rate, maternal cell contamination, or reporting time between clinician- and pathologist-procured samples despite delay in collection time for laboratory samples. Clinical samples had more microbial overgrowth. Compared to samples collected at bedside, samples collected in the laboratory had a lower rate of microbial contamination with similar growth and maternal cell contamination rates, despite prolonged time to collection. Collecting samples both at bedside and in the laboratory is unnecessary.

  3. 9 CFR 327.11 - Receipts to importers for import product samples.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... product samples. 327.11 Section 327.11 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE... laboratory examination are to be used exclusively for that purpose, official receipts shall be issued and... collected, date of collection, and that the sample was collected for laboratory examination. The duplicate...

  4. Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories.

    PubMed

    Wallin, Olof; Söderberg, Johan; Van Guelpen, Bethany; Stenlund, Hans; Grankvist, Kjell; Brulin, Christine

    2010-09-01

    Scand J Caring Sci; 2010; 24; 581-591 
 Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories   Most errors in venous blood testing result from human mistakes occurring before the sample reach the laboratory.   To survey venous blood sampling (VBS) practices in hospital wards and to compare practices with hospital laboratories.   Staff in two hospitals (all wards) and two hospital laboratories (314 respondents, response rate 94%), completed a questionnaire addressing issues relevant to the collection of venous blood samples for clinical chemistry testing.   The findings suggest that instructions for patient identification and the collection of venous blood samples were not always followed. For example, 79% of the respondents reported the undesirable practice (UDP) of not always using wristbands for patient identification. Similarly, 87% of the respondents noted the UDP of removing venous stasis after the sampling is finished. Compared with the ward staff, a significantly higher proportion of the laboratory staff reported desirable practices regarding the collection of venous blood samples. Neither education nor the existence of established sampling routines was clearly associated with VBS practices among the ward staff.   The results of this study, the first of its kind, suggest that a clinically important risk of error is associated with VBS in the surveyed wards. Most important is the risk of misidentification of patients. Quality improvement of blood sample collection is clearly needed, particularly in hospital wards. © 2009 The Authors. Journal compilation © 2009 Nordic College of Caring Science.

  5. Sample integrity evaluation and EPA method 325B interlaboratory comparison for select volatile organic compounds collected diffusively on Carbopack X sorbent tubes

    NASA Astrophysics Data System (ADS)

    Oliver, Karen D.; Cousett, Tamira A.; Whitaker, Donald A.; Smith, Luther A.; Mukerjee, Shaibal; Stallings, Casson; Thoma, Eben D.; Alston, Lillian; Colon, Maribel; Wu, Tai; Henkle, Stacy

    2017-08-01

    A sample integrity evaluation and an interlaboratory comparison were conducted in application of U.S. Environmental Protection Agency (EPA) Methods 325A and 325B for diffusively monitoring benzene and other selected volatile organic compounds (VOCs) using Carbopack X sorbent tubes. To evaluate sample integrity, VOC samples were refrigerated for up to 240 days and analyzed using thermal desorption/gas chromatography-mass spectrometry at the EPA Office of Research and Development laboratory in Research Triangle Park, NC, USA. For the interlaboratory comparison, three commercial analytical laboratories were asked to follow Method 325B when analyzing samples of VOCs that were collected in field and laboratory settings for EPA studies. Overall results indicate that the selected VOCs collected diffusively on sorbent tubes generally were stable for 6 months or longer when samples were refrigerated. This suggests the specified maximum 30-day storage time of VOCs collected diffusively on Carbopack X passive samplers and analyzed using Method 325B might be able to be relaxed. Interlaboratory comparison results were in agreement for the challenge samples collected diffusively in an exposure chamber in the laboratory, with most measurements within ±25% of the theoretical concentration. Statistically significant differences among laboratories for ambient challenge samples were small, less than 1 part per billion by volume (ppbv). Results from all laboratories exhibited good precision and generally agreed well with each other.

  6. Wildlife specimen collection, preservation, and shipment

    USGS Publications Warehouse

    White, C. LeAnn; Dusek, Robert J.; Franson, J. Christian; Friend, Milton; Gibbs, Samantha E.J.; Wild, Margaret A.

    2015-01-01

    Prior to collecting samples, it is important to determine the capabilities and submission criteria of the laboratory receiving the samples. Some laboratories may specialize in a limited number of tests, be equipped to accept only certain types of tissues (instead of entire carcasses), or specialize in particular species or group of animals (e.g., reptiles, birds, mammals). Diagnostic laboratories have specific requirements regarding preparation, labeling, and shipping of samples. Adherence to these requirements helps ensure the usefulness of any submitted specimens. Although laboratories may vary in the cost and turnaround times for diagnostic tests, some laboratories may be able to prioritize samples and accommodate accelerated time frames if communicated at the time of submission. Keeping a prepacked kit with basic carcass-collection supplies, including a paper copy of the specimen history form (available for download from the Web sites of most diagnostic laboratories), in the office or vehicle will decrease the chances of forgetting an essential item and decrease response time for arriving at an event.

  7. Laboratory Activity on Sample Handling and Maintaining a Laboratory Notebook through Simple pH Measurements

    ERIC Educational Resources Information Center

    Erdmann, Mitzy A.; March, Joe L.

    2016-01-01

    Sample handling and laboratory notebook maintenance are necessary skills but can seem abstract if not presented to students in context. An introductory exercise focusing on proper sample handling, data collection and laboratory notebook keeping for the general chemistry laboratory was developed to emphasize the importance of keeping an accurate…

  8. USGS Blind Sample Project: monitoring and evaluating laboratory analytical quality

    USGS Publications Warehouse

    Ludtke, Amy S.; Woodworth, Mark T.

    1997-01-01

    The U.S. Geological Survey (USGS) collects and disseminates information about the Nation's water resources. Surface- and ground-water samples are collected and sent to USGS laboratories for chemical analyses. The laboratories identify and quantify the constituents in the water samples. Random and systematic errors occur during sample handling, chemical analysis, and data processing. Although all errors cannot be eliminated from measurements, the magnitude of their uncertainty can be estimated and tracked over time. Since 1981, the USGS has operated an independent, external, quality-assurance project called the Blind Sample Project (BSP). The purpose of the BSP is to monitor and evaluate the quality of laboratory analytical results through the use of double-blind quality-control (QC) samples. The information provided by the BSP assists the laboratories in detecting and correcting problems in the analytical procedures. The information also can aid laboratory users in estimating the extent that laboratory errors contribute to the overall errors in their environmental data.

  9. Institutional practices and policies in acid-base testing: a self reported Croatian survey study on behalf of the Croatian society of medical biochemistry and laboratory medicine Working Group for acid-base balance.

    PubMed

    Dukić, Lora; Simundić, Ana-Maria

    2014-01-01

    The aim of this survey study was to assess the current practices and policies in use related to the various steps in the blood gas testing process, across hospital laboratories in Croatia. First questionnaire was sent by email to all medical biochemistry laboratories (N = 104) within general, specialized and clinical hospitals and university hospital centres to identify laboratories which perform blood gas analysis. Second questionnaire with detailed questions about sample collection, analysis and quality control procedures, was sent only to 47 laboratories identified by the first survey. Questionnaire was designed as combination of questions and statements with Likert scale. Third questionnaire was sent to all participating laboratories (N=47) for additional clarification for either indeterminate or unclear answers. Blood gas analysis is performed in 47/104 hospital laboratories in Croatia. In 25/41 (0.61) of the laboratories capillary blood gas sampling is the preferred sample type for adult patient population, whereas arterial blood sample is preferentially used in only 5/44 laboratories (0.11). Blood sampling and sample processing for capillary samples is done almost always by laboratory technicians (36/41 and 37/44, respectively), whereas arterial blood sampling is almost always done by the physician (24/29) and only rarely by a nurse (5/28). Sample acceptance criteria and sample analysis are in accordance with international recommendations for majority of laboratories. 43/44 laboratories participate in the national EQA program. POCT analyzers are installed outside of the laboratory in 20/47 (0.43) institutions. Laboratory staff is responsible for education and training of ward personnel, quality control and instrument maintenance in only 12/22, 11/20 and 9/20 institutions, respectively. Practices related to collection and analysis for blood gases in Croatia are not standardised and vary substantially between laboratories. POCT analyzers are not under the direct supervision by laboratory personnel in a large proportion of surveyed institutions. Collective efforts should be made to harmonize and improve policies and procedures related to blood gas testing in Croatian laboratories.

  10. Analysis of ground water by different laboratories: a comparison of chloride and nitrate data, Nassau and Suffolk counties, New York

    USGS Publications Warehouse

    Katz, Brian G.; Krulikas, Richard K.

    1979-01-01

    Water samples from wells in Nassau and Suffolk Counties were analyzed for chloride and nitrate. Two samples were collected at each well; one was analyzed by the U.S. Geological Survey, the other by a laboratory in the county from which the sample was taken. Results were compared statistically by paired-sample t-test to indicate the degree of uniformity among laboratory results. Chloride analyses from one of the three county laboratories differed significantly (0.95 confidence level) from that of a Geological Survey laboratory. For nitrate analyses, a significant difference (0.95 confidence level) was noted between results from two of the three county laboratories and the Geological Survey laboratory. The lack of uniformity among results reported by the participating laboratories indicates a need for continuing participation in a quality-assurance program and exercise of strong quality control from time of sample collection through analysis so that differences can be evaluated. (Kosco-USGS)

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adams, Wade C.

    Oak Ridge Institute for Science and Education (ORISE) personnel visited the United Nuclear Corporation (UNC) Naval Products site on three separate occasions during the months of October and November 2011. The purpose of these visits was to conduct confirmatory surveys of soils associated with the Argyle Street sewer line that was being removed. Soil samples were collected from six different, judgmentally determined locations in the Argyle Street sewer trench. In addition to the six soil samples collected by ORISE, four replicate soil samples were collected by Cabrera Services, Inc. (CSI) for analysis by the ORISE laboratory. Replicate samples S0010 andmore » S0011 were final status survey (FSS) bias samples; S0012 was an FSS systematic sample; and S0015 was a waste characterization sample. Six soil samples were also collected for background determination. Uranium-235 and uranium-238 concentrations were determined via gamma spectroscopy; the spectra were also reviewed for other identifiable photopeaks. Radionuclide concentrations for these soil samples are provided. In addition to the replicate samples and the samples collected by ORISE, CSI submitted three soil samples for inter-laboratory comparison analyses. One sample was from the background reference area, one was from waste characterization efforts (material inside the sewer line), and one was a FSS sample. The inter-laboratory comparison analyses results between ORISE and CSI were in agreement, except for one sample collected in the reference area. Smear results For Argyle Street sewer pipes are tabulated.« less

  12. On the improvement of blood sample collection at clinical laboratories

    PubMed Central

    2014-01-01

    Background Blood samples are usually collected daily from different collection points, such hospitals and health centers, and transported to a core laboratory for testing. This paper presents a project to improve the collection routes of two of the largest clinical laboratories in Spain. These routes must be designed in a cost-efficient manner while satisfying two important constraints: (i) two-hour time windows between collection and delivery, and (ii) vehicle capacity. Methods A heuristic method based on a genetic algorithm has been designed to solve the problem of blood sample collection. The user enters the following information for each collection point: postal address, average collecting time, and average demand (in thermal containers). After implementing the algorithm using C programming, this is run and, in few seconds, it obtains optimal (or near-optimal) collection routes that specify the collection sequence for each vehicle. Different scenarios using various types of vehicles have been considered. Unless new collection points are added or problem parameters are changed substantially, routes need to be designed only once. Results The two laboratories in this study previously planned routes manually for 43 and 74 collection points, respectively. These routes were covered by an external carrier company. With the implementation of this algorithm, the number of routes could be reduced from ten to seven in one laboratory and from twelve to nine in the other, which represents significant annual savings in transportation costs. Conclusions The algorithm presented can be easily implemented in other laboratories that face this type of problem, and it is particularly interesting and useful as the number of collection points increases. The method designs blood collection routes with reduced costs that meet the time and capacity constraints of the problem. PMID:24406140

  13. Laboratory information management system: an example of international cooperation in Namibia.

    PubMed

    Colangeli, Patrizia; Ferrilli, Monica; Quaranta, Fabrizio; Malizia, Elio; Mbulu, Rosa-Stella; Mukete, Esther; Iipumbu, Lukas; Kamhulu, Anna; Tjipura-Zaire, Georgina; Di Francesco, Cesare; Lelli, Rossella; Scacchia, Massimo

    2012-01-01

    The authors describe the project undertaken by the Istituto G. Caporale to provide a laboratory information management system (LIMS) to the Central Veterinary Laboratory (CVL) in Windhoek, Namibia. This robust laboratory management tool satisfies Namibia's information obligations under international quality standard ISO 17025:2005. The Laboratory Information Management System (LIMS) for Africa was designed to collect and manage all necessary information on samples, tests and test results. The system involves the entry of sample data on arrival, as required by Namibian sampling plans, the tracking of samples through the various sections of the CVL, the collection of test results, generation of test reports and monitoring of outbreaks through data interrogation functions, eliminating multiple registrations of the same data on paper records. It is a fundamental component of the Namibian veterinary information system.

  14. A round robin approach to the analysis of bisphenol a (BPA) in human blood samples

    PubMed Central

    2014-01-01

    Background Human exposure to bisphenol A (BPA) is ubiquitous, yet there are concerns about whether BPA can be measured in human blood. This Round Robin was designed to address this concern through three goals: 1) to identify collection materials, reagents and detection apparatuses that do not contribute BPA to serum; 2) to identify sensitive and precise methods to accurately measure unconjugated BPA (uBPA) and BPA-glucuronide (BPA-G), a metabolite, in serum; and 3) to evaluate whether inadvertent hydrolysis of BPA-G occurs during sample handling and processing. Methods Four laboratories participated in this Round Robin. Laboratories screened materials to identify BPA contamination in collection and analysis materials. Serum was spiked with concentrations of uBPA and/or BPA-G ranging from 0.09-19.5 (uBPA) and 0.5-32 (BPA-G) ng/mL. Additional samples were preserved unspiked as ‘environmental’ samples. Blinded samples were provided to laboratories that used LC/MSMS to simultaneously quantify uBPA and BPA-G. To determine whether inadvertent hydrolysis of BPA metabolites occurred, samples spiked with only BPA-G were analyzed for the presence of uBPA. Finally, three laboratories compared direct and indirect methods of quantifying BPA-G. Results We identified collection materials and reagents that did not introduce BPA contamination. In the blinded spiked sample analysis, all laboratories were able to distinguish low from high values of uBPA and BPA-G, for the whole spiked sample range and for those samples spiked with the three lowest concentrations (0.5-3.1 ng/ml). By completion of the Round Robin, three laboratories had verified methods for the analysis of uBPA and two verified for the analysis of BPA-G (verification determined by: 4 of 5 samples within 20% of spiked concentrations). In the analysis of BPA-G only spiked samples, all laboratories reported BPA-G was the majority of BPA detected (92.2 – 100%). Finally, laboratories were more likely to be verified using direct methods than indirect ones using enzymatic hydrolysis. Conclusions Sensitive and accurate methods for the direct quantification of uBPA and BPA-G were developed in multiple laboratories and can be used for the analysis of human serum samples. BPA contamination can be controlled during sample collection and inadvertent hydrolysis of BPA conjugates can be avoided during sample handling. PMID:24690217

  15. 77 FR 65714 - Agency Information Collection Activities: Proposed Collection; Comments Requested:

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-30

    ... Drug Samples Tested by Non-Federal (State and Local Government) Crime Laboratories ACTION: 60-Day... functions of the agency, including whether the information will have practical utility; --Evaluate the... Analysis Data on Drug Samples Tested by Non-Federal (State and Local Government) Crime Laboratories. (3...

  16. Field and laboratory data describing physical and chemical characteristics of metal-contaminated flood-plain deposits downstream from Lead, west-central South Dakota

    USGS Publications Warehouse

    Marron, D.C.

    1988-01-01

    Samples from metal-contaminated flood-plain sediments at 9 sites downstream from Lead, in west-central South Dakota, were collected during the summers of 1985-87 to characterize aspects of the sedimentology, chemistry, and geometry of a deposit that resulted from the discharge of a large volume of mining wastes into a river system. Field and laboratory data include stratigraphic descriptions, chemical contents and grain-size distributions of samples, and surveyed flood-plain positions of samples. This report describes sampling-site locations, and methods of sample collection and preservation, and subsequent laboratory analysis. Field and laboratory data are presented in 4 figures and 11 tables in the ' Supplemental Data ' section at the back of the report. (USGS)

  17. Hydrogeochemical and stream sediment reconnaissance basic data for Roswell quadrangle, New Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Field and laboratory data are presented for 842 water samples and 1270 sediment samples from the Roswell Quadrangle, New Mexico. The samples were collected by Los Alamos National Laboratory; laboratory analysis and data reporting were performed by the Uranium Resource Evaluation Project at Oak Ridge, Tennessee.

  18. Comparability of river suspended-sediment sampling and laboratory analysis methods

    USGS Publications Warehouse

    Groten, Joel T.; Johnson, Gregory D.

    2018-03-06

    Accurate measurements of suspended sediment, a leading water-quality impairment in many Minnesota rivers, are important for managing and protecting water resources; however, water-quality standards for suspended sediment in Minnesota are based on grab field sampling and total suspended solids (TSS) laboratory analysis methods that have underrepresented concentrations of suspended sediment in rivers compared to U.S. Geological Survey equal-width-increment or equal-discharge-increment (EWDI) field sampling and suspended sediment concentration (SSC) laboratory analysis methods. Because of this underrepresentation, the U.S. Geological Survey, in collaboration with the Minnesota Pollution Control Agency, collected concurrent grab and EWDI samples at eight sites to compare results obtained using different combinations of field sampling and laboratory analysis methods.Study results determined that grab field sampling and TSS laboratory analysis results were biased substantially low compared to EWDI sampling and SSC laboratory analysis results, respectively. Differences in both field sampling and laboratory analysis methods caused grab and TSS methods to be biased substantially low. The difference in laboratory analysis methods was slightly greater than field sampling methods.Sand-sized particles had a strong effect on the comparability of the field sampling and laboratory analysis methods. These results indicated that grab field sampling and TSS laboratory analysis methods fail to capture most of the sand being transported by the stream. The results indicate there is less of a difference among samples collected with grab field sampling and analyzed for TSS and concentration of fines in SSC. Even though differences are present, the presence of strong correlations between SSC and TSS concentrations provides the opportunity to develop site specific relations to address transport processes not captured by grab field sampling and TSS laboratory analysis methods.

  19. Hydrogeochemical and stream sediment reconnaissance basic data for Cheyenne Quadrangle, Wyoming

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-07-31

    Field and laboratory data are presented for 884 water samples and 598 sediment samples from the Cheyenne Quadrangle, Wyoming. Uranium values have been reported by Los Alamos National Laboratory in Report GJBX-106(78). The samples were collected by Los Alamos National Laboratory; laboratory analysis and data reporting were performed by the Uranium Resource Evaluation Project at Oak Ridge, Tennessee.

  20. Sample collections from healthy volunteers for biological variation estimates' update: a new project undertaken by the Working Group on Biological Variation established by the European Federation of Clinical Chemistry and Laboratory Medicine.

    PubMed

    Carobene, Anna; Strollo, Marta; Jonker, Niels; Barla, Gerhard; Bartlett, William A; Sandberg, Sverre; Sylte, Marit Sverresdotter; Røraas, Thomas; Sølvik, Una Ørvim; Fernandez-Calle, Pilar; Díaz-Garzón, Jorge; Tosato, Francesca; Plebani, Mario; Coşkun, Abdurrahman; Serteser, Mustafa; Unsal, Ibrahim; Ceriotti, Ferruccio

    2016-10-01

    Biological variation (BV) data have many fundamental applications in laboratory medicine. At the 1st Strategic Conference of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) the reliability and limitations of current BV data were discussed. The EFLM Working Group on Biological Variation is working to increase the quality of BV data by developing a European project to establish a biobank of samples from healthy subjects to be used to produce high quality BV data. The project involved six European laboratories (Milan, Italy; Bergen, Norway; Madrid, Spain; Padua, Italy; Istanbul, Turkey; Assen, The Netherlands). Blood samples were collected from 97 volunteers (44 men, aged 20-60 years; 43 women, aged 20-50 years; 10 women, aged 55-69 years). Initial subject inclusion required that participants completed an enrolment questionnaire to verify their health status. The volunteers provided blood specimens once per week for 10 weeks. A short questionnaire was completed and some laboratory tests were performed at each sampling consisting of blood collected under controlled conditions to provide serum, K2EDTA-plasma and citrated-plasma samples. Samples from six out of the 97 enroled subjects were discarded as a consequence of abnormal laboratory measurements. A biobank of 18,000 aliquots was established consisting of 120 aliquots of serum, 40 of EDTA-plasma, and 40 of citrated-plasma from each subject. The samples were stored at -80 °C. A biobank of well-characterised samples collected under controlled conditions has been established delivering a European resource to enable production of contemporary BV data.

  1. Hydrogeochemical and stream sediment reconnaissance basic data for Aztec Quadrangle, New Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-07-31

    Field and laboratory data are presented for 331 water samples and 1693 sediment samples from the Aztec Quadrangle, New Mexico. Uranium values have been reported by Los Alamos National Laboratory in Report GJBX-129(78). The samples were collected by Los Alamos National Laboratory; laboratory analysis and data reporting were performed by the Uranium Resource Evaluation Project at Oak Ridge, Tennessee.

  2. MICROBIAL LABORATORY GUIDANCE MANUAL FOR THE ...

    EPA Pesticide Factsheets

    The Long-Term 2 Enhanced Surface Water Treatment Rule Laboratory Instruction Manual will be a compilation of all information needed by laboratories and field personnel to collect, analyze, and report the microbiological data required under the rule. The manual will provide laboratories with a single source of information that currently is available from various sources including the latest versions of Methods 1622 and 1623, including all approved, equivalent modifications; the procedures for E.coli methods approved for use under the LT2ESWTR; lists of vendor sources; data recording forms; data reporting requirements; information on the Laboratory Quality Assurance Evaluation Program for the Analysis of Cryptosporidium in Water; and sample collection procedures. Although most of this information is available elsewhere, a single, comprehensive compendium containing this information is needed to aid utilities and laboratories performing the sampling and analysis activities required under the LT2 rule. This manual will serve as an instruction manual for laboratories to use when collecting data for Crypto, E. coli and turbidity.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barrett, Christopher A.; Martinez, Alonzo; McNamara, Bruce K.

    International Atom Energy Agency (IAEA) safeguard verification measures in gaseous centrifuge enrichment plants (GCEPs) rely on environmental sampling, non-destructive assay (NDA), and destructive assay (DA) sampling and analysis to determine uranium enrichment. UF6 bias defect measurements are made by DA sampling and analysis to assure that enrichment is consistent with declarations. DA samples are collected from a limited number of cylinders for high precision, offsite mass spectrometer analysis. Samples are typically drawn from a sampling tap into a UF6 sample bottle, then packaged, sealed, and shipped under IAEA chain of custody to an offsite analytical laboratory. Future DA safeguard measuresmore » may require improvements in efficiency and effectiveness as GCEP capacities increase and UF6 shipping regulations become increasingly more restrictive. The Pacific Northwest National Laboratory (PNNL) DA sampler concept and Laser Ablation Absorption Ratio Spectrometry (LAARS) assay method are under development to potentially provide DA safeguard tools that increase inspection effectiveness and reduce sample shipping constraints. The PNNL DA sampler concept uses a handheld sampler to collect DA samples for either onsite LAARS assay or offsite laboratory analysis. The DA sampler design will use a small sampling planchet that is coated with an adsorptive film to collect controlled quantities of UF6 gas directly from a cylinder or process sampling tap. Development efforts are currently underway at PNNL to enhance LAARS assay performance to allow high-precision onsite bias defect measurements. In this paper, we report on the experimental investigation to develop adsorptive films for the PNNL DA sampler concept. These films are intended to efficiently capture UF6 and then stabilize the collected DA sample prior to onsite LAARS or offsite laboratory analysis. Several porous material composite films were investigated, including a film designed to maximize the chemical adsorption and binding of gaseous UF6 onto the sampling planchet.« less

  4. Inter-laboratory comparison of radiometric culture for Mycobacterium avium subsp. paratuberculosis using raw milk from known infected herds and individual dairy cattle in Victoria.

    PubMed

    Ridge, S E; Andreata, S; Jones, K; Cantlon, K; Francis, B; Florisson, N; Gwozdz, J

    2010-07-01

    To compare the results of radiometric culture conducted in three Australian laboratories for Mycobacterium avium subsp. paratuberculosis (Mptb) using bulk vat and individual animal milk samples. Milk samples were collected from 15 cows exhibiting clinical signs of Johne's disease, and subsequently confirmed as infected with Mptb, and from the bulk milk vats on 91 farms running herds known to be infected with Mptb. Each milk sample was divided into three equivalent samples and one of each of the replicates was forwarded to the three participating laboratories. The identity and nature of the samples was protected from the study collaborators. The laboratories processed the samples and undertook radiometric culture for Mptb using their standard method. Results of testing were provided to the principal investigator for collation and analysis. In total, 2 (2.2%) of 91 vat-milk samples and 8 (53.3%) of 15 individual cows' milk samples returned positive radiometric milk culture results. Only one sample, from a clinical case of Johne's disease, was identified as positive by more than one laboratory. There were differences in the absolute frequency with which Mptb was identified in the milk samples by the collaborating laboratories. Mptb was cultured from a very small percentage of Australian raw bulk milk samples sourced from known infected herds. By contrast, Mptb was successfully cultured from half of the milk samples collected from clinically affected cows. There was no statistical difference between laboratories in the proportion of vat samples or individual animal milk samples in which Mptb was detected.

  5. Investigations of Sample Stability in Water Chemistry Samples: Implications for the National Aquatic Resource Surveys

    EPA Science Inventory

    Water samples collected for the EPA's National Aquatic Resource Surveys (NARS) typically arrive at an analytical laboratory 2 or 3 days after collection (longer if collected from a remote location), at which point they are stabilized (filtration and/or acid preservation) until an...

  6. Hydrogeochemical and stream sediment reconnaissance basic data for Philip Smith Mountains Quadrangle, Alaska

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-05-29

    Field and laboratory data are presented for 1128 water samples from the Philip Smith Mountains Quadrangle, Alaska. The samples were collected by Los Alamos Scientific Laboratory; laboratory analysis and data reporting were performed by the Uranium Resource Evaluation Project at Oak Ridge, Tennessee.

  7. Bridging the gap between sample collection and laboratory analysis: using dried blood spots to identify human exposure to chemical agents

    NASA Astrophysics Data System (ADS)

    Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.

    2016-05-01

    Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.

  8. Guidelines for the processing and quality assurance of benthic invertebrate samples collected as part of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Cuffney, T.F.; Gurtz, M.E.; Meador, M.R.

    1993-01-01

    Benthic invertebrate samples are collected as part of the U.S. Geological Survey's National Water-Quality Assessment Program. This is a perennial, multidisciplinary program that integrates biological, physical, and chemical indicators of water quality to evaluate status and trends and to develop an understanding of the factors controlling observed water quality. The Program examines water quality in 60 study units (coupled ground- and surface-water systems) that encompass most of the conterminous United States and parts of Alaska and Hawaii. Study-unit teams collect and process qualitative and semi-quantitative invertebrate samples according to standardized procedures. These samples are processed (elutriated and subsampled) in the field to produce as many as four sample components: large-rare, main-body, elutriate, and split. Each sample component is preserved in 10-percent formalin, and two components, large-rare and main-body, are sent to contract laboratories for further processing. The large-rare component is composed of large invertebrates that are removed from the sample matrix during field processing and placed in one or more containers. The main-body sample component consists of the remaining sample materials (sediment, detritus, and invertebrates) and is subsampled in the field to achieve a volume of 750 milliliters or less. The remaining two sample components, elutriate and split, are used for quality-assurance and quality-control purposes. Contract laboratories are used to identify and quantify invertebrates from the large-rare and main-body sample components according to the procedures and guidelines specified within this document. These guidelines allow the use of subsampling techniques to reduce the volume of sample material processed and to facilitate identifications. These processing procedures and techniques may be modified if the modifications provide equal or greater levels of accuracy and precision. The intent of sample processing is to determine the quantity of each taxon present in the semi-quantitative samples or to list the taxa present in qualitative samples. The processing guidelines provide standardized laboratory forms, sample labels, detailed sample processing flow charts, standardized format for electronic data, quality-assurance procedures and checks, sample tracking standards, and target levels for taxonomic determinations. The contract laboratory (1) is responsible for identifications and quantifications, (2) constructs reference collections, (3) provides data in hard copy and electronic forms, (4) follows specified quality-assurance and quality-control procedures, and (5) returns all processed and unprocessed portions of the samples. The U.S. Geological Survey's Quality Management Group maintains a Biological Quality-Assurance Unit, located at the National Water-Quality Laboratory, Arvada, Colorado, to oversee the use of contract laboratories and ensure the quality of data obtained from these laboratories according to the guidelines established in this document. This unit establishes contract specifications, reviews contractor performance (timeliness, accuracy, and consistency), enters data into the National Water Information System-II data base, maintains in-house reference collections, deposits voucher specimens in outside museums, and interacts with taxonomic experts within and outside the U.S. Geological Survey. This unit also modifies the existing sample processing and quality-assurance guidelines, establishes criteria and testing procedures for qualifying potential contract laboratories, identifies qualified taxonomic experts, and establishes voucher collections.

  9. Impact of Educational Activities in Reducing Pre-Analytical Laboratory Errors

    PubMed Central

    Al-Ghaithi, Hamed; Pathare, Anil; Al-Mamari, Sahimah; Villacrucis, Rodrigo; Fawaz, Naglaa; Alkindi, Salam

    2017-01-01

    Objectives Pre-analytic errors during diagnostic laboratory investigations can lead to increased patient morbidity and mortality. This study aimed to ascertain the effect of educational nursing activities on the incidence of pre-analytical errors resulting in non-conforming blood samples. Methods This study was conducted between January 2008 and December 2015. All specimens received at the Haematology Laboratory of the Sultan Qaboos University Hospital, Muscat, Oman, during this period were prospectively collected and analysed. Similar data from 2007 were collected retrospectively and used as a baseline for comparison. Non-conforming samples were defined as either clotted samples, haemolysed samples, use of the wrong anticoagulant, insufficient quantities of blood collected, incorrect/lack of labelling on a sample or lack of delivery of a sample in spite of a sample request. From 2008 onwards, multiple educational training activities directed at the hospital nursing staff and nursing students primarily responsible for blood collection were implemented on a regular basis. Results After initiating corrective measures in 2008, a progressive reduction in the percentage of non-conforming samples was observed from 2009 onwards. Despite a 127.84% increase in the total number of specimens received, there was a significant reduction in non-conforming samples from 0.29% in 2007 to 0.07% in 2015, resulting in an improvement of 75.86% (P <0.050). In particular, specimen identification errors decreased by 0.056%, with a 96.55% improvement. Conclusion Targeted educational activities directed primarily towards hospital nursing staff had a positive impact on the quality of laboratory specimens by significantly reducing pre-analytical errors. PMID:29062553

  10. Impact of Educational Activities in Reducing Pre-Analytical Laboratory Errors: A quality initiative.

    PubMed

    Al-Ghaithi, Hamed; Pathare, Anil; Al-Mamari, Sahimah; Villacrucis, Rodrigo; Fawaz, Naglaa; Alkindi, Salam

    2017-08-01

    Pre-analytic errors during diagnostic laboratory investigations can lead to increased patient morbidity and mortality. This study aimed to ascertain the effect of educational nursing activities on the incidence of pre-analytical errors resulting in non-conforming blood samples. This study was conducted between January 2008 and December 2015. All specimens received at the Haematology Laboratory of the Sultan Qaboos University Hospital, Muscat, Oman, during this period were prospectively collected and analysed. Similar data from 2007 were collected retrospectively and used as a baseline for comparison. Non-conforming samples were defined as either clotted samples, haemolysed samples, use of the wrong anticoagulant, insufficient quantities of blood collected, incorrect/lack of labelling on a sample or lack of delivery of a sample in spite of a sample request. From 2008 onwards, multiple educational training activities directed at the hospital nursing staff and nursing students primarily responsible for blood collection were implemented on a regular basis. After initiating corrective measures in 2008, a progressive reduction in the percentage of non-conforming samples was observed from 2009 onwards. Despite a 127.84% increase in the total number of specimens received, there was a significant reduction in non-conforming samples from 0.29% in 2007 to 0.07% in 2015, resulting in an improvement of 75.86% ( P <0.050). In particular, specimen identification errors decreased by 0.056%, with a 96.55% improvement. Targeted educational activities directed primarily towards hospital nursing staff had a positive impact on the quality of laboratory specimens by significantly reducing pre-analytical errors.

  11. Determination of the anionic surfactant di(ethylhexyl) sodium sulfosuccinate in water samples collected from Gulf of Mexico coastal waters before and after landfall of oil from the Deepwater Horizon oil spill, May to October, 2010

    USGS Publications Warehouse

    Gray, James L.; Kanagy, Leslie K.; Furlong, Edward T.; McCoy, Jeff W.; Kanagy, Chris J.

    2011-01-01

    On April 22, 2010, the explosion on and subsequent sinking of the Deepwater Horizon oil drilling platform resulted in the release of crude oil into the Gulf of Mexico. At least 4.4 million barrels had been released into the Gulf of Mexico through July 15, 2010, 10 to 29 percent of which was chemically dispersed, primarily using two dispersant formulations. Initially, the dispersant Corexit 9527 was used, and when existing stocks of that formulation were exhausted, Corexit 9500 was used. Over 1.8 million gallons of the two dispersants were applied in the first 3 months after the spill. This report presents the development of an analytical method to analyze one of the primary surfactant components of both Corexit formulations, di(ethylhexyl) sodium sulfosuccinate (DOSS), the preliminary results, and the associated quality assurance/quality control (QA/QC) from samples collected from various points on the Gulf Coast between Texas and Florida. Seventy water samples and 8 field QC samples were collected before the predicted landfall of oil (pre-landfall) on the Gulf Coast, and 51 water samples and 10 field QC samples after the oil made landfall (post-landfall). Samples were collected in Teflon(Registered) bottles and stored at -20(degrees)C until analysis. Extraction of whole-water samples used sorption onto a polytetrafluoroethylene (PTFE) filter to isolate DOSS, with subsequent 50 percent methanol/water elution of the combined dissolved and particulate DOSS fractions. High-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) was used to identify and quantify DOSS by the isotope dilution method, using a custom-synthesized 13C4-DOSS labeled standard. Because of the ubiquitous presence of DOSS in laboratory reagent water, a chromatographic column was installed in the LC/MS/MS between the system pumps and the sample injector that separated this ambient background DOSS contamination from the sample DOSS, minimizing one source of blank contamination. Laboratory and field QA/QC for pre-landfall samples included laboratory reagent spike and blank samples, a total of 34 replicate analyses for the 78 environmental and field blank samples, and 11 randomly chosen laboratory matrix spike samples. Laboratory and field QA/QC for post-landfall samples included laboratory reagent spike and blank samples, a laboratory 'in-bottle' duplicate for each sample, and analysis of 24 randomly chosen laboratory matrix spike samples. Average DOSS recovery of 89(+/-)9.5 percent in all native (non-13C4-DOSS ) spikes was observed, with a mean relative percent difference between sample duplicates of 36 percent. The reporting limit for this analysis was 0.25 micrograms per liter due to blank limitations; DOSS was not detected in any samples collected in October (after oil landfall at certain study sites) above that concentration. It was detected prior to oil landfall above 0.25 micrograms per liter in 3 samples, but none exceeded the Environmental Protection Agency aquatic life criteria of 40 micrograms per liter.

  12. Selected quality assurance data for water samples collected by the US Geological Survey, Idaho National Engineering Laboratory, Idaho, 1980 to 1988

    USGS Publications Warehouse

    Wegner, S.J.

    1989-01-01

    Multiple water samples from 115 wells and 3 surface water sites were collected between 1980 and 1988 for the ongoing quality assurance program at the Idaho National Engineering Laboratory. The reported results from the six laboratories involved were analyzed for agreement using descriptive statistics. The constituents and properties included: tritium, plutonium-238, plutonium-239, -240 (undivided), strontium-90, americium-241, cesium-137, total dissolved chromium, selected dissolved trace metals, sodium, chloride, nitrate, selected purgeable organic compounds, and specific conductance. Agreement could not be calculated for purgeable organic compounds, trace metals, some nitrates and blank sample analyses because analytical uncertainties were not consistently reported. However, differences between results for most of these data were calculated. The blank samples were not analyzed for differences. The laboratory results analyzed using descriptive statistics showed a median agreement between all useable data pairs of 95%. (USGS)

  13. Barratt collects sample from WRS

    NASA Image and Video Library

    2009-05-19

    ISS019-E-017918 (19 May 2009) --- Astronaut Michael Barratt, Expedition 19/20 flight engineer, collects a sample from the Water Recovery System (WRS) in the Destiny laboratory of the International Space Station.

  14. Sampling procedure for lake or stream surface water chemistry

    Treesearch

    Robert Musselman

    2012-01-01

    Surface waters collected in the field for chemical analyses are easily contaminated. This research note presents a step-by-step detailed description of how to avoid sample contamination when field collecting, processing, and transporting surface water samples for laboratory analysis.

  15. Radionuclides, stable isotopes, inorganic constituents, and organic compounds in water from selected wells and springs from the southern boundary of the Idaho National Engineering Laboratory to the Hagerman area, Idaho, 1993

    USGS Publications Warehouse

    Bartholomay, Roy C.; Edwards, Daniel D.; Campbell, Linford J.

    1994-01-01

    The U.S. Geological Survey and the Idaho Department of Water Resources, in response to a request from the U.S. Department of Energy, sampled 19 sites as part of a long-term project to monitor water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering Laboratory to the Hagerman area. Water samples were collected and analyzed for selected radionuclides, stable isotopes, inorganic constituents, and organic compounds. The samples were collected from seven irrigation wells, four domestic wells, two springs, one stock well, three dairy wells, one observation well, and one commercial well. Two quality assurance samples also were collected and analyzed. None of the radionuclides, inorganic constituents, or organic compounds exceeded the established maximum contaminant levels for drinking water. Most of the radionuclide and inorganic constituent concen- trations exceeded their respective laboratory reporting levels. All samples analyzed for surfactants and dissolved organic carbon had concentrations that exceeded their reporting level. Ethylbenzene concentrations exceeded the reporting level in one water sample.

  16. Summary of data from onsite and laboratory analyses of surface water and marsh porewater from South Florida Water Management District Water Conservation Areas, the Everglades, South Florida, March 1995

    USGS Publications Warehouse

    Reddy, Michael M.; Gunther, Charmaine D.

    2012-01-01

    This report presents results of chemical analysis for samples collected during March, 1995, as part of a study to quantify the interaction of aquatic organic material (referred to here as dissolved organic carbon with dissolved metal ions). The work was done in conjunction with the South Florida Water Management District, the U.S. Environmental Protection Agency, the U.S. Geological Survey South Florida Ecosystems Initiative, and the South Florida National Water Quality Assessment Study Unit. Samples were collected from surface canals and from marsh sites. Results are based on onsite and laboratory measurements for 27 samples collected at 10 locations. The data file contains sample description, dissolved organic carbon concentration and specific ultraviolet absorbance, and additional analytical data for samples collected at several sites in the Water Conservation Areas, the Everglades, south Florida.

  17. THE QUANTIFICATION OF AQUEOUS TRACERS IN LABORATORY AQUIFER MODELS USING LIGHT TRANSMISSION VISUALIZATION METHOD

    EPA Science Inventory

    The quantification of solute concentrations in laboratory aquifer models has been largely limited to the use of sampling ports, from which samples are collected for external analysis. One of the drawbacks to this method is that the act of sampling may disturb plume dynamics and ...

  18. National survey on the pre-analytical variability in a representative cohort of Italian laboratories.

    PubMed

    Lippi, Giuseppe; Montagnana, Martina; Giavarina, Davide

    2006-01-01

    Owing to remarkable advances in automation, laboratory technology and informatics, the pre-analytical phase has become the major source of variability in laboratory testing. The present survey investigated the development of several pre-analytical processes within a representative cohort of Italian clinical laboratories. A seven-point questionnaire was designed to investigate the following issues: 1a) the mean outpatient waiting time before check-in and 1b) the mean time from check-in to sample collection; 2) the mean time from sample collection to analysis; 3) the type of specimen collected for clinical chemistry testing; 4) the degree of pre-analytical automation; 5a) the number of samples shipped to other laboratories and 5b) the availability of standardised protocols for transportation; 6) the conditions for specimen storage; and 7) the availability and type of guidelines for management of unsuitable specimens. The questionnaire was administered to 150 laboratory specialists attending the SIMEL (Italian Society of Laboratory Medicine) National Meeting in June 2006. 107 questionnaires (71.3%) were returned. Data analysis revealed a high degree of variability among laboratories for the time required for check-in, outpatient sampling, sample transportation to the referral laboratory and analysis upon the arrival. Only 31% of laboratories have automated some pre-analytical steps. Of the 87% of laboratories that ship specimens to other facilities without sample preparation, 19% have no standardised protocol for transportation. For conventional clinical chemistry testing, 74% of the laboratories use serum evacuated tubes (59% with and 15% without serum separator), whereas the remaining 26% use lithium-heparin evacuated tubes (11% with and 15% without plasma separator). The storage period and conditions for rerun/retest vary widely. Only 63% of laboratories have a codified procedure for the management of unsuitable specimens, which are recognised by visual inspection (69%) or automatic detection (29%). Only 56% of the laboratories have standardised procedures for the management of unsuitable specimens, which vary widely on a local basis. The survey highlights broad heterogeneity in several pre-analytical processes among Italian laboratories. The lack of reliable guidelines encompassing evidence-based practice is a major problem for the standardisation of this crucial part of the testing process and represents a major challenge for laboratory medicine in the 2000s.

  19. Hematology and pathology devices; reclassification; restricted devices; OTC test sample collection systems for drugs of abuse testing. Food and Drug Administration, HHS. Final rule.

    PubMed

    2000-04-07

    The Food and Drug Administration (FDA) is reclassifying over-the-counter (OTC) test sample collection systems for drugs of abuse testing from class III (premarket approval) into class I (general controls) and exempting them from premarket notification (510(k)) and current good manufacturing practice (CGMP) requirements. FDA is also designating OTC test sample collection systems for drugs of abuse testing as restricted devices under the Federal Food, Drug, and Cosmetic Act (the act) and establishing restrictions intended to assure consumers that: The underlying laboratory test(s) are accurate and reliable; the laboratory performing the test(s) has adequate expertise and competency; and the product has adequate labeling and methods of communicating test results to consumers. Finally, FDA is adding a conforming amendment to the existing classification regulation for specimen transport and storage containers to clarify that it does not apply to specimen transport and storage containers that are part of an OTC test sample collection system for the purpose of testing for the presence of drugs of abuse or their metabolites in a laboratory.

  20. Comparing and Combining Data across Multiple Sources via Integration of Paired-sample Data to Correct for Measurement Error

    PubMed Central

    Huang, Yunda; Huang, Ying; Moodie, Zoe; Li, Sue; Self, Steve

    2014-01-01

    Summary In biomedical research such as the development of vaccines for infectious diseases or cancer, measures from the same assay are often collected from multiple sources or laboratories. Measurement error that may vary between laboratories needs to be adjusted for when combining samples across laboratories. We incorporate such adjustment in comparing and combining independent samples from different labs via integration of external data, collected on paired samples from the same two laboratories. We propose: 1) normalization of individual level data from two laboratories to the same scale via the expectation of true measurements conditioning on the observed; 2) comparison of mean assay values between two independent samples in the Main study accounting for inter-source measurement error; and 3) sample size calculations of the paired-sample study so that hypothesis testing error rates are appropriately controlled in the Main study comparison. Because the goal is not to estimate the true underlying measurements but to combine data on the same scale, our proposed methods do not require that the true values for the errorprone measurements are known in the external data. Simulation results under a variety of scenarios demonstrate satisfactory finite sample performance of our proposed methods when measurement errors vary. We illustrate our methods using real ELISpot assay data generated by two HIV vaccine laboratories. PMID:22764070

  1. [Comparison of the determination of cyclosporin-A in blood samples collected on filter paper and by the ordinary technique].

    PubMed

    Azevedo, L S; Manrique, R; Sabbaga, E

    1995-01-01

    Monitoring cyclosporin-A (CsA) blood levels is of utmost importance for the rational use of this drug. Although many centers perform transplants, in Brazil there are few laboratories able to measure CsA blood levels. Therefore making blood samples reach the laboratory emerged as a problem. Collection of blood on filter paper has been a technique used for a long time in special cases. PURPOSE--To confirm the usefulness of measuring CsA blood levels in blood samples collected on filter paper and in the usual way. METHOD--We studied twenty renal cadaver kidney recipients who were receiving CsA, azathioprine and prednisone. Ninety five blood samples were collected and divided into two aliquots. One of them was sent routinely to one laboratory to perform whole blood CsA measurements. From the other aliquot, 20 microliters were pipetted on filter paper. When dried they were mailed to the other laboratory, where, after elution, CsA was measured. In both cases radioimmunoassay with polyclonal antibody was used. RESULTS--Linear correlation between both measurements revealed r = 0.81 with no statistical difference. CONCLUSION--The technique showed to be useful in clinical practice. In countries with continental size, as Brazil, it may be very helpful.

  2. [The running status of Chinese Measles Laboratory Network in 2008].

    PubMed

    Zhang, Yan; Xu, Song-Tao; Jiang, Xiao-Hong

    2009-04-01

    To evaluate the running status of Measles laboratory network of China (Hong Kong, Macao and Taiwan were excluded) in 2008. To analyze the database of Measles laboratory network surveillance of the year 2008, and the database of serologic and virologic surveillance of National laboratory for Measles in Chinese Centers for Disease Control and Prevention(CCDC), then the indicators of the running of Measles laboratory network of China were analyzed. 1, serologic surveillance: 107,160 Measles sera samples were collected between Feburary and September of 2008, and the collection rate was 77.93%; 53 778 samples were qualified and positive for IgM, the positive percentage was 50.2%. 2, Virologic surveillance: 287 Measles viral isolates were isolated by 18 provincial Measles laboratories in 2008, all were certified as H1a genotype, H1a genotype was still the predominant genotype circulating in China; 29 Rubella viral isolates were isolated by 4 provincial Measles laboratories in 2008, all belonged to 1E genotype. 3, Laboratory quality control: National laboratory for Measles passed the proficiency test and on-site review in 2008; all provincial Measles laboratories passed the sera samples recheck and proficiency test hold by National laboratory for Measles in 2008; Tianjin, Shanxi, Shandong, Zhejiang, Jilin, Hubei, provincial Measles laboratory passed the on-site review by WHO. The running status of Chinese Measles laboratory network was good in 2008, and good laboratory quality control system was also set up, methods such as specimens collection, serologic detection, cell culture and viral isolation, etc, were standardized, and applied to Chinese Measles laboratory network, and it provided important scientific basis for eradication Measles in the year of 2012.

  3. An efficient field and laboratory workflow for plant phylotranscriptomic projects1

    PubMed Central

    Yang, Ya; Moore, Michael J.; Brockington, Samuel F.; Timoneda, Alfonso; Feng, Tao; Marx, Hannah E.; Walker, Joseph F.; Smith, Stephen A.

    2017-01-01

    Premise of the study: We describe a field and laboratory workflow developed for plant phylotranscriptomic projects that involves cryogenic tissue collection in the field, RNA extraction and quality control, and library preparation. We also make recommendations for sample curation. Methods and Results: A total of 216 frozen tissue samples of Caryophyllales and other angiosperm taxa were collected from the field or botanical gardens. RNA was extracted, stranded mRNA libraries were prepared, and libraries were sequenced on Illumina HiSeq platforms. These included difficult mucilaginous tissues such as those of Cactaceae and Droseraceae. Conclusions: Our workflow is not only cost effective (ca. $270 per sample, as of August 2016, from tissue to reads) and time efficient (less than 50 h for 10–12 samples including all laboratory work and sample curation), but also has proven robust for extraction of difficult samples such as tissues containing high levels of secondary compounds. PMID:28337391

  4. 76 FR 42130 - Agency Information Collection Activities: BioWatch Filter Holder Log

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-18

    ... DEPARTMENT OF HOMELAND SECURITY Agency Information Collection Activities: BioWatch Filter Holder...) assigned responsibility for installing and removing filters from aerosol collection devices and transportation to local laboratories for sample analysis. A standard filter log form is completed for each sample...

  5. 76 FR 24504 - Agency Information Collection Activities: BioWatch Filter Holder Log

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-02

    ... DEPARTMENT OF HOMELAND SECURITY Agency Information Collection Activities: BioWatch Filter Holder...) assigned responsibility for installing and removing filters from aerosol collection devices and transportation to local laboratories for sample analysis. A standard filter log form is completed for each sample...

  6. Macroinvertebrate community sample collection methods and data collected from Sand Creek and Medano Creek, Great Sand Dunes National Park and Preserve, Colorado, 2005–07

    USGS Publications Warehouse

    Ford, Morgan A.; Zuellig, Robert E.; Walters, David M.; Bruce, James F.

    2016-08-11

    This report provides a table of site descriptions, sample information, and semiquantitative aquatic macroinvertebrate data from 105 samples collected between 2005 and 2007 from 7 stream sites within the Sand Creek and Medano Creek watersheds in Great Sand Dunes National Park and Preserve, Saguache County, Colorado. Additionally, a short description of sample collection methods and laboratory sample processing procedures is presented. These data were collected in anticipation of assessing the potential effects of fish toxicants on macroinvertebrates.

  7. Chapter A5. Section 6.1.F. Wastewater, Pharmaceutical, and Antibiotic Compounds

    USGS Publications Warehouse

    Lewis, Michael Edward; Zaugg, Steven D.

    2003-01-01

    The USGS differentiates between samples collected for analysis of wastewater compounds and those collected for analysis of pharmaceutical and antibiotic compounds, based on the analytical schedule for the laboratory method. Currently, only the wastewater laboratory method for field-filtered samples (SH1433) is an approved, routine (production) method. (The unfiltered wastewater method LC 8033 also is available but requires a proposal for custom analysis.) At this time, analysis of samples for pharmaceutical and antibiotic compounds is confined to research studies and is available only on a custom basis.

  8. 2nd NUTRITION w/Repository collection period

    NASA Image and Video Library

    2011-10-04

    ISS029-E-015096 (4 Oct. 2011) --- In the International Space Station?s Kibo laboratory, NASA astronaut Mike Fossum, Expedition 29 commander, prepares to insert samples into a Minus Eighty Laboratory Freezer for ISS (MELFI-1) dewar tray for the second NUTRITION w/Repository collection period.

  9. 2nd NUTRITION w/Repository collection period

    NASA Image and Video Library

    2011-10-04

    ISS029-E-015110 (4 Oct. 2011) --- In the International Space Station?s Kibo laboratory, NASA astronaut Mike Fossum, Expedition 29 commander, inserts a dewar tray of samples into the Minus Eighty Laboratory Freezer for ISS (MELFI-1) for the second NUTRITION w/Repository collection period.

  10. THE QUANTIFICATION OF AQUEOUS TRACERS IN LABORATORY AQUIFER MODELS USING A LIGHT TRANSMISSION VISUALIZATION METHOD - 3

    EPA Science Inventory

    The quantification of solute concentrations in laboratory aquifer models has been largely limited to the use of sampling ports, from which samples are collected for external analysis. One of the drawbacks to this method is that the act of sampling may disturb plume dynamics and ...

  11. THE QUANTIFICATION OF AQUEOUS TRACERS IN LABORATORY AQUIFER MODELS USING A LIGHT TRANSMISSION VISUALIZATION METHOD - 2

    EPA Science Inventory

    The quantification of solute concentrations in laboratory aquifer models has been largely limited to the use of sampling ports, from which samples are collected for external analysis. One of the drawbacks to this method is that the act of sampling may disturb plume dynamics and ...

  12. THE QUANTIFICATION OF AQUEOUS TRACERS IN LABORATORY AQUIFER MODELS USING A LIGHT TRANSMISSION VISUALIZATION METHOD - 1

    EPA Science Inventory

    The quantification of solute concentrations in laboratory aquifer models has been largely limited to the use of sampling ports, from which samples are collected for external analysis. One of the drawbacks to this method is that the act of sampling may disturb plume dynamics and ...

  13. Pettit uses a Grab Sample Container in the U.S. Laboratory during Expedition Six

    NASA Image and Video Library

    2003-01-22

    ISS006-E-20834 (22 January 2003) --- Astronaut Donald R. Pettit, Expedition Six NASA ISS science officer, holds a Grab Sample Container (GSC) in the Destiny laboratory on the International Space Station (ISS). GSC is used for collecting air samples as part of ISS environmental monitoring.

  14. LUNAR SAMPLES - APOLLO 11

    NASA Image and Video Library

    1969-08-03

    S69-40749 (July 1969) --- Dr. Grant Heikan, MSC and a Lunar Sample Preliminary Examination Team member, examines lunar material in a sieve from the bulk sample container which was opened in the Biopreparation Laboratory of the Lunar Receiving Laboratory. The samples were collected by astronauts Neil A. Armstrong and Edwin E. Aldrin Jr. during their lunar surface extravehicular activity on July 20, 1969.

  15. Design and evaluation of a field study on the contamination of selected volatile organic compounds and wastewater-indicator compounds in blanks and groundwater samples

    USGS Publications Warehouse

    Thiros, Susan A.; Bender, David A.; Mueller, David K.; Rose, Donna L.; Olsen, Lisa D.; Martin, Jeffrey D.; Bernard, Bruce; Zogorski, John S.

    2011-01-01

    The Field Contamination Study (FCS) was designed to determine the field processes that tend to result in clean field blanks and to identify potential sources of contamination to blanks collected in the field from selected volatile organic compounds (VOCs) and wastewater-indicator compounds (WICs). The VOCs and WICs analyzed in the FCS were detected in blanks collected by the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) Program during 1996–2008 and 2002–08, respectively. To minimize the number of variables, the study required ordering of supplies just before sampling, storage of supplies and equipment in clean areas, and use of adequate amounts of purge-and-trap volatile-grade methanol and volatile pesticide-grade blank water (VPBW) to clean sampling equipment and to collect field blanks.Blanks and groundwater samples were collected during 2008–09 at 16 sites, which were a mix of water-supply and monitoring wells, located in 9 States. Five different sample types were collected for the FCS at each site: (1) a source-solution blank collected at the USGS National Water Quality Laboratory (NWQL) using laboratory-purged VPBW, (2) source-solution blanks collected in the field using laboratory-purged VPBW, (3) source-solution blanks collected in the field using field-purged VPBW, (4) a field blank collected using field-purged VPBW, and (5) a groundwater sample collected from a well. The source-solution blank and field-blank analyses were used to identify, quantify, and document extrinsic contamination and to help determine the sources and causes of data-quality problems that can affect groundwater samples.Concentrations of compounds detected in FCS analyses were quantified and results were stored in the USGS National Water Information System database after meeting rigorous identification and quantification criteria. The study also utilized information provided by laboratory analysts about evidence indicating the presence of selected compounds, using less rigorous identification criteria than is required for reporting data to the National Water Information System database. For the FCS, these data are considered adequate to indicate "evidence of presence," and were used only for diagnostic purposes. Evidence of VOCs and WICs at low concentrations near or less than the long-term method detection level can indicate a contamination problem that could affect future datasets if method detection levels were ever to be lowered.

  16. Uncertainties in stormwater runoff data collection from a small urban catchment, Southeast China.

    PubMed

    Huang, Jinliang; Tu, Zhenshun; Du, Pengfei; Lin, Jie; Li, Qingsheng

    2010-01-01

    Monitoring data are often used to identify stormwater runoff characteristics and in stormwater runoff modelling without consideration of their inherent uncertainties. Integrated with discrete sample analysis and error propagation analysis, this study attempted to quantify the uncertainties of discrete chemical oxygen demand (COD), total suspended solids (TSS) concentration, stormwater flowrate, stormwater event volumes, COD event mean concentration (EMC), and COD event loads in terms of flow measurement, sample collection, storage and laboratory analysis. The results showed that the uncertainties due to sample collection, storage and laboratory analysis of COD from stormwater runoff are 13.99%, 19.48% and 12.28%. Meanwhile, flow measurement uncertainty was 12.82%, and the sample collection uncertainty of TSS from stormwater runoff was 31.63%. Based on the law of propagation of uncertainties, the uncertainties regarding event flow volume, COD EMC and COD event loads were quantified as 7.03%, 10.26% and 18.47%.

  17. 78 FR 51183 - Agency Information Collection Activities: Proposed Collection; Comment Request; Restructuring of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-20

    ... Collection Activities: Proposed Collection; Comment Request; Restructuring of the Stationary Source Audit... potentially affected by this action are those laboratories that supply audit samples. [[Page 51184

  18. EVALUATION OF SPERM CHROMATIN STRUCTURE ASSAY (SCSA REGISTERED TRADEMARK) IN HUMAN SPERM AFTER SIMULATED OVERNIGHT SHIPMENT

    EPA Science Inventory

    Home semen collection kits allow men to collect a sample at their convenience and send it via overnight mail to the laboratory. Benefits of this approach include facilitated sample collection from different geographic locations, minimized variability through analysis by a central...

  19. [Logistics of collection and transportation of biological samples and the organization of the central laboratory in the ELSA-Brasil].

    PubMed

    Fedeli, Ligia G; Vidigal, Pedro G; Leite, Claudia Mendes; Castilhos, Cristina D; Pimentel, Robércia Anjos; Maniero, Viviane C; Mill, Jose Geraldo; Lotufo, Paulo A; Pereira, Alexandre C; Bensenor, Isabela M

    2013-06-01

    The ELSA (Estudo Longitudinal de Saúde do Adulto - Brazilian Longitudinal Study for Adult Health) is a multicenter cohort study which aims at the identification of risk factors associated with type 2 diabetes and cardiovascular diseases in the Brazilian population. The paper describes the strategies for the collection, processing, transportation, and quality control of blood and urine tests in the ELSA. The study decided to centralize the tests at one single laboratory. The processing of the samples was performed at the local laboratories, reducing the weight of the material to be transported, and diminishing the costs of transportation to the central laboratory at the Universidade de São Paulo Hospital. The study included tests for the evaluation of diabetes, insulin resistance, dyslipidemia, electrolyte abnormalities, thyroid hormones, uric acid, hepatic enzyme abnormalities, inflammation, and total blood cell count. In addition, leukocyte DNA, urine, plasma and serum samples were stored. The central laboratory performed approximately 375,000 tests.

  20. Hydrogeochemical and stream sediment reconnaissance basic data for Las Cruces quadrangle, New Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-08-31

    Field and laboratory data are presented for 501 water samples and 1817 sediment samples from the Las Cruces Quadrangle, New Mexico. The samples were collected and uranium analysis performed by Los Alamos National Laboratory; multielement analysis and data reporting were performed by the Uranium Resource Evaluation Project at Oak Ridge, Tennessee.

  1. Spectral signature selection for mapping unvegetated soils

    NASA Technical Reports Server (NTRS)

    May, G. A.; Petersen, G. W.

    1975-01-01

    Airborne multispectral scanner data covering the wavelength interval from 0.40-2.60 microns were collected at an altitude of 1000 m above the terrain in southeastern Pennsylvania. Uniform training areas were selected within three sites from this flightline. Soil samples were collected from each site and a procedure developed to allow assignment of scan line and element number from the multispectral scanner data to each sampling location. These soil samples were analyzed on a spectrophotometer and laboratory spectral signatures were derived. After correcting for solar radiation and atmospheric attenuation, the laboratory signatures were compared to the spectral signatures derived from these same soils using multispectral scanner data. Both signatures were used in supervised and unsupervised classification routines. Computer-generated maps using the laboratory and multispectral scanner derived signatures resulted in maps that were similar to maps resulting from field surveys. Approximately 90% agreement was obtained between classification maps produced using multispectral scanner derived signatures and laboratory derived signatures.

  2. Hole at Buckskin Drilled Days Before Landing Anniversary

    NASA Image and Video Library

    2015-08-05

    NASA's Curiosity Mars Rover drilled this hole to collect sample material from a rock target called "Buckskin" on July 30, 2015, during the 1060th Martian day, or sol, of the rover's work on Mars. The diameter is slightly smaller than a U.S. dime. Curiosity landed on Mars on Aug. 6, 2012, Universal Time (evening of Aug. 5, PDT). The rover took this image with the Mars Hand Lens Imager (MAHLI) camera, which is mounted on the same robotic arm as the sample-collecting drill. Rock powder from the collected sample was subsequently delivered to a laboratory inside the rover for analysis. The rover's drill did not experience any sign during this sample collection of an intermittent short-circuiting issue that was detected earlier in 2015. The Buckskin target is in an area near "Marias Pass" on lower Mount Sharp where Curiosity had detected unusually high levels of silica and hydrogen. MAHLI was built by Malin Space Science Systems, San Diego. NASA's Jet Propulsion Laboratory, a division of the California Institute of Technology in Pasadena, manages the Mars Science Laboratory Project for the NASA Science Mission Directorate, Washington. JPL designed and built the project's Curiosity rover. http://photojournal.jpl.nasa.gov/catalog/PIA19804

  3. Quality-Assurance/Quality-Control Manual for Collection and Analysis of Water-Quality Data in the Ohio District, US Geological Survey

    USGS Publications Warehouse

    Francy, D.S.; Jones, A.L.; Myers, Donna N.; Rowe, G.L.; Eberle, Michael; Sarver, K.M.

    1998-01-01

    The U.S. Geological Survey (USGS), Water Resources Division (WRD), requires that quality-assurance/quality-control (QA/QC) activities be included in any sampling and analysis program. Operational QA/QC procedures address local needs while incorporating national policies. Therefore, specific technical policies were established for all activities associated with water-quality project being done by the Ohio District. The policies described in this report provide Ohio District personnel, cooperating agencies, and others with a reference manual on QA/QC procedures that are followed in collecitng and analyzing water-quality samples and reporting water-quality information in the Ohio District. The project chief, project support staff, District Water-Quality Specialist, and District Laboratory Coordinator are all involved in planning and implementing QA/QC activities at the district level. The District Chief and other district-level managers provide oversight, and the Regional Water-Quality Specialist, Office of Water Quality (USGS headquarters), and the Branch of Quality Systems within the Office of Water Quality create national QA/QC polices and provide assistance to District personnel. In the literature, the quality of all measurement data is expressed in terms of precision, variability, bias, accuracy, completeness, representativeness, and comparability. In the Ohio District, bias and variability will be used to describe quality-control data generated from samples in the field and laboratory. Each project chief must plan for implementation and financing of QA/QC activities necessary to achieve data-quality objectives. At least 15 percent of the total project effort must be directed toward QA/QC activities. Of this total, 5-10 percent will be used for collection and analysis of quality-control samples. This is an absolute minimum, and more may be required based on project objectives. Proper techniques must be followed in the collection and processing of surface-water, ground-water, biological, precipitation, bed-sediment, bedload, suspended-sediment, and solid-phase samples. These techniques are briefly described in this report and are extensively documented. The reference documents listed in this report will be kept by the District librarian and District Water-Quality Specialist and updated regularly so that they are available to all District staff. Proper handling and documentation before, during, and after field activities are essential to ensure the integrity of the sample and to correct erroneous reporting of data results. Field sites are to be properly identified and entered into the data base before field data-collection activities begin. During field activities, field notes are to be completed and sample bottles appropriately labeled a nd stored. After field activities, all paperwork is to be completed promptly and samples transferred to the laboratory within allowable holding times. All equipment used by District personnel for the collection and processing of water-quality samples is to be properly operated, maintained, and calibrated by project personnel. This includes equipment for onsite measurement of water-quality characteristics (temperature, specific conductance, pH, dissolved oxygen, alkalinity, acidity, and turbidity) and equipment and instruments used for biological sampling. The District Water-Quality Specialist and District Laboratory Coordinator are responsible for preventive maintenance and calibration of equipment in the Ohio District laboratory. The USGS National Water Quality Laboratory in Arvada, Colo., is the primary source of analytical services for most project work done by the Ohio District. Analyses done at the Ohio District laboratory are usually those that must be completed within a few hours of sample collection. Contract laboratories or other USGS laboratories are sometimes used instead of the NWQL or the Ohio District laboratory. When a contract laboratory is used, the projec

  4. Preanalytical quality in clinical chemistry laboratory.

    PubMed

    Ahmad, M Imteyaz; Ramesh, K L; Kumar, Ravi

    2014-01-01

    Haemolysis is usually caused by inadequate specimen collection or preanalytical handling and is suggested to be a suitable indicator of preanalytical quality. We investigated the prevalence of detectable haemolysis in all routine venous blood samples in OPDs and IPDs to identify differences in preanalytical quality. Haemolysis index (HI) values were obtained from a Vitros 5,1 in the routine clinical chemistry laboratory for samples collected in the outpatient department (OPD) collection centres, a hospital, and inpatient departments (IPD). Haemolysis was defined as a HI > or = 15 (detection limit). Samples from the OPD with the highest prevalence of haemolysis were 6.1 times (95% confidence interval (CI) 4.0 - 9.2) more often haemolysed compared to the center with the lowest prevalence. Of the samples collected in primary health care, 10.4% were haemolysed compared to 31.1% in the IPDs (p = 0.001). A notable difference in haemolysed samples was found between the IPDs section staffed by emergency medicine physicians and the section staffed by primary health care physicians (34.8% vs. 11.3%, p = 0.001). The significant variation in haemolysis indices among the investigated units is likely to reflect varying preanalytical conditions. The HI is a valuable tool for estimation and follow-up of preanalytical quality in the health care laboratory.

  5. Database of the United States Coal Pellet Collection of the U.S. Geological Survey Organic Petrology Laboratory

    USGS Publications Warehouse

    Deems, Nikolaus J.; Hackley, Paul C.

    2012-01-01

    The Organic Petrology Laboratory (OPL) of the U.S. Geological Survey (USGS) Eastern Energy Resources Science Center in Reston, Virginia, contains several thousand processed coal sample materials that were loosely organized in laboratory drawers for the past several decades. The majority of these were prepared as 1-inch-diameter particulate coal pellets (more than 6,000 pellets; one sample usually was prepared as two pellets, although some samples were prepared in as many as four pellets), which were polished and used in reflected light petrographic studies. These samples represent the work of many scientists from the 1970s to the present, most notably Ron Stanton, who managed the OPL until 2001 (see Warwick and Ruppert, 2005, for a comprehensive bibliography of Ron Stanton's work). The purpose of the project described herein was to organize and catalog the U.S. part of the petrographic sample collection into a comprehensive database (available with this report as a Microsoft Excel file) and to compile and list published studies associated with the various sample sets. Through this work, the extent of the collection is publicly documented as a resource and sample library available to other scientists and researchers working in U.S. coal basins previously studied by organic petrologists affiliated with the USGS. Other researchers may obtain samples in the OPL collection on loan at the discretion of the USGS authors listed in this report and its associated Web page.

  6. Characterization of nutrients and fecal indicator bacteria at a concentrated swine feeding operation in Wake County, North Carolina, 2009-2011

    USGS Publications Warehouse

    Harden, Stephen L.; Rogers, Shane W.; Jahne, Michael A.; Shaffer, Carrie E.; Smith, Douglas G.

    2012-01-01

    Study sites were sampled for laboratory analysis of nutrients, total suspended solids (TSS), and (or) fecal indicator bacteria (FIB). Nutrient analyses included measurement of dissolved ammonia, total and dissolved ammonia + organic nitrogen, dissolved nitrate + nitrite, dissolved orthophosphate, and total phosphorus. The FIB analyses included measurement of Escherichia coli and enterococci. Samples of wastewater at the swine facility were collected from a pipe outfall from the swine housing units, two storage lagoons, and the spray fields for analysis of nutrients, TSS, and FIB. Soil samples collected from a spray field were analyzed for FIB. Monitoring locations were established for collecting discharge and water-quality data during storm events at three in-field runoff sites and two sites on the headwater stream (one upstream and one downstream) next to the swine facility. Stormflow samples at the five monitoring locations were collected for four storm events during 2009 to 2010 and analyzed for nutrients, TSS, and FIB. Monthly water samples also were collected during base-flow conditions at all four stream sites for laboratory analysis of nutrients, TSS, and (or) FIB.

  7. ARM Carbon Cycle Gases Flasks at SGP Site

    DOE Data Explorer

    Biraud, Sebastien

    2013-03-26

    Data from flasks are sampled at the Atmospheric Radiation Measurement Program ARM, Southern Great Plains Site and analyzed by the National Oceanic and Atmospheric Administration NOAA, Earth System Research Laboratory ESRL. The SGP site is included in the NOAA Cooperative Global Air Sampling Network. The surface samples are collected from a 60 m tower at the ARM SGP Central Facility, usually once per week in the afternoon. The aircraft samples are collected approximately weekly from a chartered aircraft, and the collection flight path is centered over the tower where the surface samples are collected. The samples are collected by the ARM and LBNL Carbon Project.

  8. Sequim Marine Research Laboratory routine environmental measurements during CY-1978. [Monitoring for laboratory-related radioactivity and pollutants in environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Houston, J.R.; Blumer, P.J.

    1979-03-01

    Environmental data collected during 1978 in the vicinity of the Marine Research Laboratory show continued compliance with all applicable state and federal regulations and furthermore show no detectable change from conditions that existed in previous years. Samples collected for radiological analysis included soil, drinking water, bay water, clams, and seaweed. Radiation dose rates at 1 meter aboveground were also measured.

  9. Tank vapor characterization project. Headspace vapor characterization of Hanford waste tank 241-BY-108: Second comparison study results from samples collected on 3/28/96

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, B.L.; Pool, K.H.; Evans, J.C.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of waste storage tank 241-BY-108 (Tank BY-108) at the Hanford Site in Washington State. The results described in this report is the second in a series comparing vapor sampling of the tank headspace using the Vapor Sampling System (VSS) and In Situ Vapor Sampling (ISVS) system without high efficiency particulate air (HEPA) prefiltration. The results include air concentrations of water (H{sub 2}O) and ammonia (NH{sub 3}), permanent gases, total non-methane organic compounds (TO-12), and individual organic analytes collected in SUMMA{trademark} canisters and on triple sorbent traps (TSTs).more » Samples were collected by Westinghouse Hanford Company (WHC) and analyzed by Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, sample volume measurements provided by WHC.« less

  10. Differences in results of analyses of concurrent and split stream-water samples collected and analyzed by the US Geological Survey and the Illinois Environmental Protection Agency, 1985-91

    USGS Publications Warehouse

    Melching, C.S.; Coupe, R.H.

    1995-01-01

    During water years 1985-91, the U.S. Geological Survey (USGS) and the Illinois Environmental Protection Agency (IEPA) cooperated in the collection and analysis of concurrent and split stream-water samples from selected sites in Illinois. Concurrent samples were collected independently by field personnel from each agency at the same time and sent to the IEPA laboratory, whereas the split samples were collected by USGS field personnel and divided into aliquots that were sent to each agency's laboratory for analysis. The water-quality data from these programs were examined by means of the Wilcoxon signed ranks test to identify statistically significant differences between results of the USGS and IEPA analyses. The data sets for constituents and properties identified by the Wilcoxon test as having significant differences were further examined by use of the paired t-test, mean relative percentage difference, and scattergrams to determine if the differences were important. Of the 63 constituents and properties in the concurrent-sample analysis, differences in only 2 (pH and ammonia) were statistically significant and large enough to concern water-quality engineers and planners. Of the 27 constituents and properties in the split-sample analysis, differences in 9 (turbidity, dissolved potassium, ammonia, total phosphorus, dissolved aluminum, dissolved barium, dissolved iron, dissolved manganese, and dissolved nickel) were statistically significant and large enough to con- cern water-quality engineers and planners. The differences in concentration between pairs of the concurrent samples were compared to the precision of the laboratory or field method used. The differences in concentration between pairs of the concurrent samples were compared to the precision of the laboratory or field method used. The differences in concentration between paris of split samples were compared to the precision of the laboratory method used and the interlaboratory precision of measuring a given concentration or property. Consideration of method precision indicated that differences between concurrent samples were insignificant for all concentrations and properties except pH, and that differences between split samples were significant for all concentrations and properties. Consideration of interlaboratory precision indicated that the differences between the split samples were not unusually large. The results for the split samples illustrate the difficulty in obtaining comparable and accurate water-quality data.

  11. Collection methods and quality assessment for Esche-richia coli, water quality, and microbial source tracking data within Tumacácori National Historical Park and the upper Santa Cruz River, Arizona, 2015-16

    USGS Publications Warehouse

    Paretti, Nicholas; Coes, Alissa L.; Kephart, Christopher M.; Mayo, Justine

    2018-03-05

    Tumacácori National Historical Park protects the culturally important Mission, San José de Tumacácori, while also managing a portion of the ecologically diverse riparian corridor of the Santa Cruz River. This report describes the methods and quality assurance procedures used in the collection of water samples for the analysis of Escherichia coli (E. coli), microbial source tracking markers, suspended sediment, water-quality parameters, turbidity, and the data collection for discharge and stage; the process for data review and approval is also described. Finally, this report provides a quantitative assessment of the quality of the E. coli, microbial source tracking, and suspended sediment data.The data-quality assessment revealed that bias attributed to field and laboratory contamination was minimal, with E. coli detections in only 3 out of 33 field blank samples analyzed. Concentrations in the field blanks were several orders of magnitude lower than environmental concentrations. The microbial source tracking (MST) field blank was below the detection limit for all MST markers analyzed. Laboratory blanks for E. coli at the USGS Arizona Water Science Center and laboratory blanks for MST markers at the USGS Ohio Water Microbiology Laboratory were all below the detection limit. Irreplicate data for E. coli and suspended sediment indicated that bias was not introduced to the data by combining samples collected using discrete sampling methods with samples collected using automatic sampling methods.The split and sequential E. coli replicate data showed consistent analytical variability and a single equation was developed to explain the variability of E. coli concentrations. An additional analysis of analytical variability for E. coli indicated analytical variability around 18 percent relative standard deviation and no trend was observed in the concentration during the processing and analysis of multiple split-replicates. Two replicate samples were collected for MST and individual markers were compared for a base flow and flood sample. For the markers found in common between the two types of samples, the relative standard deviation for the base flow sample was more than 3 times greater than the markers in the flood sample. Sequential suspended sediment replicates had a relative standard deviation of about 1.3 percent, indicating that environmental and analytical variability was minimal.A holding time review and laboratory study analysis supported the extended holding times required for this investigation. Most concentrations for flood and base-flow samples were within the theoretical variability specified in the most probable number approach suggesting that extended hold times did not overly influence the final concentrations reported.

  12. Study design and percent recoveries of anthropogenic organic compounds with and without the addition of ascorbic acid to preserve water samples containing free chlorine, 2004-06

    USGS Publications Warehouse

    Valder, Joshua F.; Delzer, Gregory C.; Price, Curtis V.; Sandstrom, Mark W.

    2008-01-01

    The National Water-Quality Assessment (NAWQA) Program of the U.S. Geological Survey (USGS) began implementing Source Water-Quality Assessments (SWQAs) in 2002 that focus on characterizing the quality of source water and finished water of aquifers and major rivers used by some of the larger community water systems in the United States. As used for SWQA studies, source water is the raw (ambient) water collected at the supply well prior to water treatment (for ground water) or the raw (ambient) water collected from the river near the intake (for surface water). Finished water is the water that is treated, which typically involves, in part, the addition of chlorine or other disinfection chemicals to remove pathogens, and is ready to be delivered to consumers. Finished water is collected before the water enters the distribution system. This report describes the study design and percent recoveries of anthropogenic organic compounds (AOCs) with and without the addition of ascorbic acid to preserve water samples containing free chlorine. The percent recoveries were determined by using analytical results from a laboratory study conducted in 2004 by the USGS's National Water Quality Laboratory (NWQL) and from data collected during 2004-06 for a field study currently (2008) being conducted by the USGS's NAWQA Program. The laboratory study was designed to determine if preserving samples with ascorbic acid (quenching samples) adversely affects analytical performance under controlled conditions. During the laboratory study, eight samples of reagent water were spiked for each of five analytical schedules evaluated. Percent recoveries from these samples were then compared in two ways: (1) four quenched reagent spiked samples analyzed on day 0 were compared with four quenched reagent spiked samples analyzed on day 7 or 14, and (2) the combined eight quenched reagent spiked samples analyzed on day 0, 7, or 14 were compared with eight laboratory reagent spikes (LRSs). Percent recoveries from the quenched reagent spiked samples that were analyzed at two different times (day 0 and day 7 or 14) can be used to determine the stability of the quenched samples held for an amount of time representative of the normal amount of time between sample collection and analysis. The comparison between the quenched reagent spiked samples and the LRSs can be used to determine if quenching samples adversely affects the analytical performance under controlled conditions. The field study began in 2004 and is continuing today (February 2008) to characterize the effect of quenching on field-matrix spike recoveries and to better understand the potential oxidation and transformation of 277 AOCs. Three types of samples were collected from 11 NAWQA Study Units across the Nation: (1) quenched finished-water samples (not spiked), (2) quenched finished-water spiked samples, and (3) nonquenched finished-water spiked samples. Percent recoveries of AOCs in quenched and nonquenched finished-water spiked samples collected during 2004-06 are presented. Comparisons of percent recoveries between quenched and nonquenched spiked samples can be used to show how quenching affects finished-water samples. A maximum of 6 surface-water and 7 ground-water quenched finished-water spiked samples paired with nonquenched finished-water spiked samples were analyzed. Analytical results for the field study are presented in two ways: (1) by surface-water supplies or ground-water supplies, and (2) by use (or source) group category for surface-water and ground-water supplies. Graphical representations of percent recoveries for the quenched and nonquenched finished-water spiked samples also are presented.

  13. Water-Quality Data for Selected National Park Units within the Southern Colorado Plateau Network, Arizona, Utah, Colorado, and New Mexico, Water Years 2005 and 2006

    USGS Publications Warehouse

    Macy, Jamie P.; Monroe, Stephen A.

    2006-01-01

    The National Park Service initiated a Level 1 Water-Quality Inventory program to provide water-quality data to park managers so informed natural resource management decisions could be made. Level 1 water-quality data were collected by the U.S. Geological Survey Arizona Water Science Center at 57 sites in 13 National Park units located in the Southern Colorado Plateau Inventory and Monitoring network in water years 2005 and 2006. These data describe the current water-quality at selected sites within the park units and provide information for monitoring future trends. Water samples were collected three times at each type of site including wells, springs, seeps, tinajas, rivers, a lake, and an irrigation ditch. Field measurements were taken at each site and they included pH, specific conductance, temperature, barometric pressure, dissolved oxygen, alkalinity, turbidity, and discharge rates where applicable. Water samples collected were sent to the U.S. Geological Survey National Water Quality Laboratory and analyzed for major ions, trace elements, and nutrients. The National Water Quality Laboratory also analyzed selected samples for mercury and petroleum hydrocarbons. Additional samples at selected sites were collected and analyzed for cyanide, radiochemistry, and suspended sediment by U.S. Geological Survey contract labs. Fecal-indicator bacteria (Escherichia coli) were sampled for at selected sites as another indicator of water quality. Quality control for this study was achieved through proper training of field personnel, use of standard U.S. Geological Survey field and laboratory protocols, collection of sample blanks and replicates, and a thorough review of the water-quality analyses. Measured field pH ranged from 6.0 to 8.8, within normal range for springs and rivers, at most sites. Concentrations of dissolved solids ranged from 48 to 8,680 mg/L and the majority of samples had concentrations of dissolved solids below 900 mg/L. Trace-element concentrations at most sites were at or near the laboratory reporting levels. The highest overall trace-element concentrations were found at U.S. Highway 160 Spring near Park Entrance to Mesa Verde National Park. Concentrations of uranium in samples at all sites ranged from below the detection limit to 55.7 ?g/L. Water samples from selected sites were analyzed for total petroleum hydrocarbons and concentrations of total petroleum hydrocarbons were at or above the laboratory detection limit in samples at six National Park units. Ten sites were sampled for Escherichia coli and positive counts were found at 9 out of the ten sites, the highest colony counts were found at Chinle Creek at Chinle, AZ in Canyon de Chelly National Monument. Measured concentrations of dissolved ammonia, nitrite, and nitrate were at or near laboratory reporting levels at most sites; nitrate concentrations ranged from below the reporting limit (0.047 mg/L) to 9.77 mg/L. Samples that were analyzed for mercury had concentrations below or at the laboratory reporting level. Concentrations of cyanide were less than the laboratory reporting level for all samples except two, Spruce Tree House Spring in Mesa Verde National Park and Pine Tree Canyon Tinaja in Canyon de Chelly National Monument, which had average concentrations of .042 and .011 ?g/L respectively. Gross alpha/beta radioactivity counts were below the U.S. Environmental Protection Agency maximum contaminant level except for samples from Casa Chiquita Well Middle at Chaco Culture National Historical Park which averaged 35 pCi/L. Suspended-sediment concentrations were variable and ranged from 10 to 150,000 mg/L.

  14. Vascular Blood Collection protocol samples into MELFI

    NASA Image and Video Library

    2011-10-18

    iss029e028495 (10/18/2011) --- Japan Aerospace Exploration Agency astronaut Satoshi Furukawa,Expedition 29 flight engineer,prepares to put samples from the CSA (Canadian Space Agency) Vascular Blood Collection protocol into the MELFI-1 (Minus Eighty Laboratory Freezer for ISS 1) unit.

  15. Laboratory diagnosis of gestational diabetes: An in silico investigation into the effects of pre-analytical processing on the diagnostic sensitivity and specificity of the oral glucose tolerance test.

    PubMed

    Mansell, Erin; Lunt, Helen; Docherty, Paul

    2017-06-01

    Delayed separation of red cells from plasma causes pre analytical glucose loss, which in turn results in an under-diagnosis of GDM (gestational diabetes) based on the OGTT (oral glucose tolerance test). In silico investigations may help laboratory decision making, when exploring pragmatic improvements to sample processing. Late pregnancy 0, 1 and 2h 75g OGTT values were obtained from two distinct populations of pregnant women: 1. Values derived from the HAPO (Hyperglycemia and Adverse Pregnancy Outcome) Study and 2. New Zealand women identified as at higher risk of GDM by their caregivers, undergoing OGTT during routine antenatal care. In both populations studied, in silico modelling focussed on the effects of pre-analytical delays in plasma separation, when using fluoride collection tubes. Using a model that 'batched' samples from the three OGTT collection times, diagnostic sensitivity was estimated as follows: 66.1% for HAPO research population and 48.4% for the 1305 women receiving routine antenatal care. If samples were not batched, but processed shortly after each blood sample was collected, then sensitivity increased to 81%. Exploration of a range of clinical and laboratory scenarios using in silico modelling, showed that delaying the processing of pregnancy OGTT samples, using batched sample collection into fluoride tubes, causes unacceptable loss of GDM diagnostic sensitivity across two distinct population groups. This modelling approach will hopefully provide information that helps with final decision making around improved laboratory processing techniques. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  16. [Assessment of biological sampling's quality in a medical laboratory: case of Côte d' Ivoire Institute Pasteur].

    PubMed

    Kouassi-M'Bengue, Alphonsine; Koffi, Stephane; Manizan, Pascale; Ouattara, Abdoulaye; N'Douba, Adele Kacou; Dosso, Mireille

    2008-01-01

    Assurance quality is important in medical laboratory, but in Africa, few laboratories are involved in this process. The aim of this study was to assess biological sampling's quality in a bacteriological laboratory. A cross sectional study was undertaken in medical bacteriological laboratory of Côte d' Ivoire Institute Pasteur during 6 months. All urines, saddles, and bronchial expectorations collected from ambulatory patients during this period were included in the study. The quality of urine's, saddles and bronchial expectorations' sampling for a bacteriological analysis was evaluated. An interview based on Guidelines of good laboratories practices and referential ISO 15189 was used. A total of 300 samples were indexed. On a total of 300 recorded biological samples, 224 (74.7%) were not in conformity. In 87.5% of the cases of nonconformities, an antibiotic's treatment were preliminary instituted before the sampling. Corrective actions were carried in the laboratory on 30 samples with 56.6% for the urines, 26.7% for the saddles and 16.7% for the bronchial expectorations. At the end of this study, it arises that the quality of the biological sampling received at the medical bacteriology laboratory need to be improved.

  17. Headspace vapor characterization of Hanford Waste Tank 241-S-102: Results from samples collected on January 26, 1996. Tank Vapor Characterization Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, J.C.; Thomas, B.L.; Pool, K.H.

    1996-07-01

    This report describes the results of vapor samples obtained to compare vapor sampling of the tank headspace using the Vapor Sampling System (VSS) and In Situ Vapor Sampling System (ISVS) with and without particulate prefiltration. Samples were collected from the headspace of waste storage tank 241-S-102 (Tank S-102) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) was contracted by Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for water, ammonia, permanent gases, total nonmethane hydrocarbons (TNMHCs, also known as TO-12), and organic analytes in samples collected in SUMMA{trademark} canisters and on triple sorbentmore » traps (TSTs) from the tank headspace. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sampling and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Sampling and Analysis Plan for Tank Vapor Sampling Comparison Test{close_quote}, and the sample jobs were designated S6007, S6008, and S6009. Samples were collected by WHC on January 26, 1996, using the VSS, a truck-based sampling method using a heated probe; and the ISVS with and without particulate prefiltration.« less

  18. Headspace vapor characterization of Hanford Waste Tank 241-BY-108: Results from samples collected January 23, 1996. Tank Vapor Characterization Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pool, K.H.; Evans, J.C.; Thomas, B.L.

    1996-07-01

    This report describes the results of vapor samples obtained to compare vapor sampling of the tank headspace using the Vapor Sampling System (VSS) and In Situ Vapor Sampling System (ISVS) with and without particulate prefiltration. Samples were collected from the headspace of waste storage tank 241-BY-108 (Tank BY-108) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) was contracted by Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for water, ammonia, permanent gases, total nonmethane hydrocarbons (TNMHCs, also known as TO-12), and organic analytes in samples collected in SUMMA{trademark} canisters and on triple sorbentmore » traps (TSTs) from the tank headspace. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sampling and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Sampling and Analysis Plan for Tank Vapor Sampling Comparison Test{close_quotes}, and the sample jobs were designated S6004, S6005, and S6006. Samples were collected by WHC on January 23, 1996, using the VSS, a truck-based sampling method using a heated probe; and the ISVS with and without particulate prefiltration.« less

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, G.L.

    This data package satisfies the requirement for a format IV, final report. It is a follow-up to the 45-day safety screen report for tank AP-104. Evaporator candidate feed from tank 241-AP-104 (hereafter referred to as AP-104) was characterized for physical, inorganic, organic and radiochemical parameters by the Westinghouse Hanford Company, 222-S Laboratory, and by the Battelle Pacific Northwest National Laboratory (PNNL), Analytical Chemistry Laboratory (ACL) as directed by the Tank Sample and Analysis Plan (TSAP), References 1 through 4. Preliminary data in the form of summary analytical tables were provided to the project in advance of this final report tomore » enable early estimation of evaporator operational parameters, using the Predict modeling program. Laboratory analyses at ACL Laboratory was performed according to the TSAP. Analyses were performed at the 222-S Laboratory as defined and specified in the TSAP and the Laboratory`s Quality Assurance Plan, References 5 and 6. Any deviations from the instructions documented in the TSAP are discussed in this narrative and are supported with additional documentation. SAMPLING The TSAP, section 2, provided sampling information for waste samples collected from tank AP-104. The bottle-on-a-string method was used to collect liquid grab samples from the tank. Each glass sample bottle was amber, precleaned, and contained approximately 100 milliliters. Each bottle was closed with a teflon seal cap (or teflon septum for volatile organic analysis samples). Field blank samples were prepared by placing deionized water into sampling bottles, lowering the unclosed bottles into the riser for a period of time, retrieving them from the riser, and then closing the bottles with the same types of caps used for the tank samples. None of the samples were preserved by acidification. Upon receipt, the sample bottles destined for organic analyses were placed in a refrigerator. No attempt was made during sampling to assure the complete filling of the bottles so as to exclude all headspace. These actions were consistent with safety procedures, which attempt to limit personnel exposure to hazardous ionizing radiation.« less

  20. About Rubella (German Measles, Three-Day Measles)

    MedlinePlus

    ... Professionals Pregnancy and Rubella Rubella Vaccination Travelers’ Health Information on Rubella Laboratory Testing CDC Laboratory Testing & Procedures Serology RNA Detection Genetic Analysis Specimen Collection, Storage, & Shipment Sample Submission Q&A ...

  1. Rubella (German Measles, Three-Day Measles) Photos

    MedlinePlus

    ... Professionals Pregnancy and Rubella Rubella Vaccination Travelers’ Health Information on Rubella Laboratory Testing CDC Laboratory Testing & Procedures Serology RNA Detection Genetic Analysis Specimen Collection, Storage, & Shipment Sample Submission Q&A ...

  2. Detection of Campylobacter in human faecal samples in Fiji.

    PubMed

    Devi, Aruna; Wilkinson, Jenny; Mahony, Timothy; Vanniasinkam, Thiru

    2014-01-01

    Data on campylobacteriosis in developed countries are well documented; in contrast, few studies on campylobacteriosis have been conducted in developing countries. This study was undertaken to test for Campylobacter in human faecal samples sent to the two major pathology laboratories in Fiji. A total of 408 diarrhoeal faecal samples were collected from the two major hospital pathology laboratories in Central Fiji (Suva) and Western Fiji (Lautoka) between December 2012 and February 2013 and from June to July 2013. Samples were analysed for the presence of Campylobacter using polymerase chain reaction (PCR) based methods. Campylobacter was detected in 241/408 (59.1%) of samples tested using PCR. Samples from children aged less than five accounted for 21.6% of positive cases. Campylobacter was detected in 59.1% of diarrhoeal samples collected from the two main laboratories in Fiji. A high proportion of children under five years with Campylobacter has been reported in other countries and could be due to parents being more likely to seek medical attention. Further studies are required to confirm the species of Campylobacter that are predominantly associated with gastroenteritis in Fiji.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Volume II of the Site Environmental Report for 2006 is provided by Ernest Orlando Lawrence Berkeley National Laboratory as a supplemental appendix to Volume I, which contains the body of the report. Volume II contains the environmental monitoring and sampling data used to generate summary results of routine and nonroutine activities at the Laboratory (except for groundwater sampling data, which may be found in the reports referred to in Chapter 4). Volume I summarizes the results from analyses of the data. The results from sample collections are more comprehensive in Volume II than in Volume I: For completeness, all resultsmore » from sample collections that began or ended in calendar year (CY) 2006 are included in this volume. However, the samples representing CY 2005 data have not been used in the summary results that are reported in Volume I. (For example, although ambient air samples collected on January 2, 2006, are presented in Volume II, they represent December 2005 data and are not included in Table 4-2 in Volume I.)« less

  4. Evaluation of FTA cards as a laboratory and field sampling device for the detection of foot-and-mouth disease virus and serotyping by RT-PCR and real-time RT-PCR.

    PubMed

    Muthukrishnan, Madhanmohan; Singanallur, Nagendrakumar B; Ralla, Kumar; Villuppanoor, Srinivasan A

    2008-08-01

    Foot-and-mouth disease virus (FMDV) samples transported to the laboratory from far and inaccessible areas for serodiagnosis pose a major problem in a tropical country like India, where there is maximum temperature fluctuation. Inadequate storage methods lead to spoilage of FMDV samples collected from clinically positive animals in the field. Such samples are declared as non-typeable by the typing laboratories with the consequent loss of valuable epidemiological data. The present study evaluated the usefulness of FTA Classic Cards for the collection, shipment, storage and identification of the FMDV genome by RT-PCR and real-time RT-PCR. The stability of the viral RNA, the absence of infectivity and ease of processing the sample for molecular methods make the FTA cards a useful option for transport of FMDV genome for identification and serotyping. The method can be used routinely for FMDV research as it is economical and the cards can be transported easily in envelopes by regular document transport methods. Live virus cannot be isolated from samples collected in FTA cards, which is a limitation. This property can be viewed as an advantage as it limits the risk of transmission of live virus.

  5. Bed-Sediment Sampling and Analysis for Physical and Chemical Properties of the Lower Mississippi River near Memphis, Tennessee

    USGS Publications Warehouse

    Blanchard, Robert A.; Wagner, Daniel M.; Evans, Dennis A.

    2010-01-01

    In February 2010, the U.S. Geological Survey, in cooperation with the U.S. Army Corps of Engineers, Memphis District, investigated the presence of inorganic elements and organic compounds in bed sediments of the lower Mississippi River. Selected sites were located in the navigation channel near river miles 737, 773, and 790 near Memphis, Tennessee. Bed-sediment samples were collected using a Shipek grab sampler mounted to a boom crane with a motorized winch. Samples then were processed and shipped to the U.S. Geological Survey Sediment Laboratory in Rolla, Missouri, the USGS National Water Quality Laboratory in Denver, Colorado, and to TestAmerica Laboratory, Inc. in West Sacramento, California. Samples were analyzed for grain size, inorganic elements (including mercury), and organic compounds. Chemical results were tabulated and listed with sediment-quality guidelines and presented with the physical property results. All of the bed material samples collected during this investigation yielded concentrations that were less than the Consensus-Based Probable Effect Concentration guidelines. The physical properties were tabulated and listed using a standard U.S. Geological Survey scale of sizes by class for sediment analysis. All of the samples collected during this investigation indicated a percent composition mostly comprised of sand, ranging from less than 0.125 millimeters to less than 2 millimeters.

  6. Pre-analytical issues in the haemostasis laboratory: guidance for the clinical laboratories.

    PubMed

    Magnette, A; Chatelain, M; Chatelain, B; Ten Cate, H; Mullier, F

    2016-01-01

    Ensuring quality has become a daily requirement in laboratories. In haemostasis, even more than in other disciplines of biology, quality is determined by a pre-analytical step that encompasses all procedures, starting with the formulation of the medical question, and includes patient preparation, sample collection, handling, transportation, processing, and storage until time of analysis. This step, based on a variety of manual activities, is the most vulnerable part of the total testing process and is a major component of the reliability and validity of results in haemostasis and constitutes the most important source of erroneous or un-interpretable results. Pre-analytical errors may occur throughout the testing process and arise from unsuitable, inappropriate or wrongly handled procedures. Problems may arise during the collection of blood specimens such as misidentification of the sample, use of inadequate devices or needles, incorrect order of draw, prolonged tourniquet placing, unsuccessful attempts to locate the vein, incorrect use of additive tubes, collection of unsuitable samples for quality or quantity, inappropriate mixing of a sample, etc. Some factors can alter the result of a sample constituent after collection during transportation, preparation and storage. Laboratory errors can often have serious adverse consequences. Lack of standardized procedures for sample collection accounts for most of the errors encountered within the total testing process. They can also have clinical consequences as well as a significant impact on patient care, especially those related to specialized tests as these are often considered as "diagnostic". Controlling pre-analytical variables is critical since this has a direct influence on the quality of results and on their clinical reliability. The accurate standardization of the pre-analytical phase is of pivotal importance for achieving reliable results of coagulation tests and should reduce the side effects of the influence factors. This review is a summary of the most important recommendations regarding the importance of pre-analytical factors for coagulation testing and should be a tool to increase awareness about the importance of pre-analytical factors for coagulation testing.

  7. GHSI EMERGENCY RADIONUCLIDE BIOASSAY LABORATORY NETWORK - SUMMARY OF THE SECOND EXERCISE.

    PubMed

    Li, Chunsheng; Bartizel, Christine; Battisti, Paolo; Böttger, Axel; Bouvier, Céline; Capote-Cuellar, Antonio; Carr, Zhanat; Hammond, Derek; Hartmann, Martina; Heikkinen, Tarja; Jones, Robert L; Kim, Eunjoo; Ko, Raymond; Koga, Roberto; Kukhta, Boris; Mitchell, Lorna; Morhard, Ryan; Paquet, Francois; Quayle, Debora; Rulik, Petr; Sadi, Baki; Sergei, Aleksanin; Sierra, Inmaculada; de Oliveira Sousa, Wanderson; Szab, Gyula

    2017-05-01

    The Global Health Security Initiative (GHSI) established a laboratory network within the GHSI community to develop collective surge capacity for radionuclide bioassay in response to a radiological or nuclear emergency as a means of enhancing response capability, health outcomes and community resilience. GHSI partners conducted an exercise in collaboration with the WHO Radiation Emergency Medical Preparedness and Assistance Network and the IAEA Response and Assistance Network, to test the participating laboratories (18) for their capabilities in in vitro assay of biological samples, using a urine sample spiked with multiple high-risk radionuclides (90Sr, 106Ru, 137Cs, and 239Pu). Laboratories were required to submit their reports within 72 h following receipt of the sample, using a pre-formatted template, on the procedures, methods and techniques used to identify and quantify the radionuclides in the sample, as well as the bioassay results with a 95% confidence interval. All of the participating laboratories identified and measured all or some of the radionuclides in the sample. However, gaps were identified in both the procedures used to assay multiple radionuclides in one sample, as well as in the methods or techniques used to assay specific radionuclides in urine. Two-third of the participating laboratories had difficulties in determining all the radionuclides in the sample. Results from this exercise indicate that challenges remain with respect to ensuring that results are delivered in a timely, consistent and reliable manner to support medical interventions. Laboratories within the networks are encouraged to work together to develop and maintain collective capabilities and capacity for emergency bioassay, which is an important component of radiation emergency response. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. GHSI Emergency Radionuclide Bioassay Laboratory Network - Summary of the Second Exercise

    PubMed Central

    Li, Chunsheng; Bartizel, Christine; Battisti, Paolo; Böttger, Axel; Bouvier, Céline; Capote-Cuellar, Antonio; Carr, Zhanat; Hammond, Derek; Hartmann, Martina; Heikkinen, Tarja; Jones, Robert L.; Kim, Eunjoo; Ko, Raymond; Koga, Roberto; Kukhta, Boris; Mitchell, Lorna; Morhard, Ryan; Paquet, Francois; Quayle, Debora; Rulik, Petr; Sadi, Baki; Sergei, Aleksanin; Sierra, Inmaculada; de Oliveira Sousa, Wanderson; Szabó, Gyula

    2017-01-01

    The Global Health Security Initiative (GHSI) established a laboratory network within the GHSI community to develop collective surge capacity for radionuclide bioassay in response to a radiological or nuclear emergency as a means of enhancing response capability, health outcomes and community resilience. GHSI partners conducted an exercise in collaboration with the WHO REMPAN (Radiation Emergency Medical Preparedness and Assistance Network) and the IAEA RANET (Response and Assistance Network), to test the participating laboratories (18) for their capabilities in in vitro assay of biological samples, using a urine sample spiked with multiple high-risk radionuclides (90Sr, 106Ru, 137Cs, and 239Pu). Laboratories were required to submit their reports within 72 hours following receipt of the sample, using a pre-formatted template, on the procedures, methods and techniques used to identify and quantify the radionuclides in the sample, as well as the bioassay results with a 95% confidence interval. All of the participating laboratories identified and measured all or some of the radionuclides in the sample. However, gaps were identified in both the procedures used to assay multiple radionuclides in one sample, as well as in the methods or techniques used to assay specific radionuclides in urine. Two third of the participating laboratories had difficulties in determining all the radionuclides in the sample. Results from this exercise indicate that challenges remain with respect to ensuring that results are delivered in a timely, consistent and reliable manner to support medical interventions. Laboratories within the networks are encouraged to work together to develop and maintain collective capabilities and capacity for emergency bioassay, which is an important component of radiation emergency response. PMID:27574317

  9. The Hawaiian Freshwater Algal Database (HfwADB): a laboratory LIMS and online biodiversity resource

    PubMed Central

    2012-01-01

    Background Biodiversity databases serve the important role of highlighting species-level diversity from defined geographical regions. Databases that are specially designed to accommodate the types of data gathered during regional surveys are valuable in allowing full data access and display to researchers not directly involved with the project, while serving as a Laboratory Information Management System (LIMS). The Hawaiian Freshwater Algal Database, or HfwADB, was modified from the Hawaiian Algal Database to showcase non-marine algal specimens collected from the Hawaiian Archipelago by accommodating the additional level of organization required for samples including multiple species. Description The Hawaiian Freshwater Algal Database is a comprehensive and searchable database containing photographs and micrographs of samples and collection sites, geo-referenced collecting information, taxonomic data and standardized DNA sequence data. All data for individual samples are linked through unique 10-digit accession numbers (“Isolate Accession”), the first five of which correspond to the collection site (“Environmental Accession”). Users can search online for sample information by accession number, various levels of taxonomy, habitat or collection site. HfwADB is hosted at the University of Hawaii, and was made publicly accessible in October 2011. At the present time the database houses data for over 2,825 samples of non-marine algae from 1,786 collection sites from the Hawaiian Archipelago. These samples include cyanobacteria, red and green algae and diatoms, as well as lesser representation from some other algal lineages. Conclusions HfwADB is a digital repository that acts as a Laboratory Information Management System for Hawaiian non-marine algal data. Users can interact with the repository through the web to view relevant habitat data (including geo-referenced collection locations) and download images of collection sites, specimen photographs and micrographs, and DNA sequences. It is publicly available at http://algae.manoa.hawaii.edu/hfwadb/. PMID:23095476

  10. The Hawaiian Algal Database: a laboratory LIMS and online resource for biodiversity data

    PubMed Central

    Wang, Norman; Sherwood, Alison R; Kurihara, Akira; Conklin, Kimberly Y; Sauvage, Thomas; Presting, Gernot G

    2009-01-01

    Background Organization and presentation of biodiversity data is greatly facilitated by databases that are specially designed to allow easy data entry and organized data display. Such databases also have the capacity to serve as Laboratory Information Management Systems (LIMS). The Hawaiian Algal Database was designed to showcase specimens collected from the Hawaiian Archipelago, enabling users around the world to compare their specimens with our photographs and DNA sequence data, and to provide lab personnel with an organizational tool for storing various biodiversity data types. Description We describe the Hawaiian Algal Database, a comprehensive and searchable database containing photographs and micrographs, geo-referenced collecting information, taxonomic checklists and standardized DNA sequence data. All data for individual samples are linked through unique accession numbers. Users can search online for sample information by accession number, numerous levels of taxonomy, or collection site. At the present time the database contains data representing over 2,000 samples of marine, freshwater and terrestrial algae from the Hawaiian Archipelago. These samples are primarily red algae, although other taxa are being added. Conclusion The Hawaiian Algal Database is a digital repository for Hawaiian algal samples and acts as a LIMS for the laboratory. Users can make use of the online search tool to view and download specimen photographs and micrographs, DNA sequences and relevant habitat data, including georeferenced collecting locations. It is publicly available at . PMID:19728892

  11. Challenges for conducting blood collection and biochemical analysis in a large multicenter school-based study with adolescents: lessons from ERICA in Brazil.

    PubMed

    Cureau, Felipe Vogt; Bloch, Katia Vergetti; Henz, Aline; Schaan, Camila W; Klein, Carlos Henrique; Oliveira, Cecília Lacroix de; Giannini, Denise Tavares; Leon, Elisa Brosina de; Abreu, Gabriela de Azevedo; Telo, Gabriela Heiden; Dias, Glauber Monteiro; Carvalho, Kênia Mara Baiocchi de; Barufaldi, Laura Augusta; Kuschnir, Maria Cristina Caetano; Szklo, Moyses; Montenegro, Renan; Silva, Thiago Luiz Nogueira da; Ekelund, Ulf; Schaan, Beatriz D

    2017-05-18

    The Study of Cardiovascular Risk in Adolescents (ERICA) is a pioneering study that aimed to assess the prevalence of cardiovascular risk factors, including metabolic syndrome components in Brazilian adolescents. This study aims to describe the methodological aspects related to blood collection as well as to report pertaining results of the preparation, transport, storage, and exams in ERICA. Exams in ERICA were performed in a single laboratory and blood samples were collected in schools in a standardized manner. Logistics involved air transportation of samples to the reference laboratory with controlled temperature since sample collection. The serum was stored in local biorepositories in four centers to be used in future analyses. During the study, 284,247 exams were performed and rate of participation in exams was 56.2%, thus involving 40,732 adolescents. From the total, 92.6% of the samples reached the reference laboratory maintaining the temperature between 0-10°C. No clinical significant changes in results due to temperature changes were identified. External quality control recorded satisfactory results in 98.7% of the evaluations. Four biorepositories with samples of 7,785 adolescents were created. Thus, we can consider that the logistics adopted in ERICA was fairly successful and description of this as well as the difficulties experienced in Brazil can inform and facilitate the planning of future studies, especially in developing countries.

  12. Environmental Technology (Laboratory Analysis and Environmental Sampling) Curriculum Development Project. Final Report.

    ERIC Educational Resources Information Center

    Hinojosa, Oscar V.; Guillen, Alfonso

    A project assessed the need and developed a curriculum for environmental technology (laboratory analysis and environmental sampling) in the emerging high technology centered around environmental safety and health in Texas. Initial data were collected through interviews by telephone and in person and through onsite visits. Additional data was…

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anheier, Norman C.; Cannon, Bret D.; Martinez, Alonzo

    The International Atomic Energy Agency’s (IAEA’s) long-term research and development plan calls for more cost-effective and efficient safeguard methods to detect and deter misuse of gaseous centrifuge enrichment plants (GCEPs). The IAEA’s current safeguards approaches at GCEPs are based on a combination of routine and random inspections that include environmental sampling and destructive assay (DA) sample collection from UF6 in-process material and selected cylinders. Samples are then shipped offsite for subsequent laboratory analysis. In this paper, a new DA sample collection and onsite analysis approach that could help to meet challenges in transportation and chain of custody for UF6 DAmore » samples is introduced. This approach uses a handheld sampler concept and a Laser Ablation, Laser Absorbance Spectrometry (LAARS) analysis instrument, both currently under development at the Pacific Northwest National Laboratory. A LAARS analysis instrument could be temporarily or permanently deployed in the IAEA control room of the facility, in the IAEA data acquisition cabinet, for example. The handheld PNNL DA sampler design collects and stabilizes a much smaller DA sample mass compared to current sampling methods. The significantly lower uranium mass reduces the sample radioactivity and the stabilization approach diminishes the risk of uranium and hydrogen fluoride release. These attributes enable safe sample handling needed during onsite LAARS assay and may help ease shipping challenges for samples to be processed at the IAEA’s offsite laboratory. The LAARS and DA sampler implementation concepts will be described and preliminary technical viability results presented.« less

  14. ARM-LBNL-NOAA Flask Sampler for Carbon Cycle Gases

    DOE Data Explorer

    Torn, Margaret

    2008-01-15

    Data from ccg-flasks are sampled at the ARM SGP site and analyzed by the NOAA Earth System Research Laboratory (ESRL) as part of the NOAA Cooperative Global Air Sampling Network. Surface samples are collected from a 60m tower at the SGP Central Facility, usually once per week on one afternoon. The aircraft samples are collected approximately weekly from a chartered aircraft, and the collection flight path is centered over the tower where the surface samples are collected. Samples are collected by the ARM/LBNL Carbon Project. CO2 flask data contains measurements of CO2 concentration and CO2 stable isotope ratios (13CO2 and C18OO) from flasks collected at the SGP site. The flask samples are collected at 2m, 4m, 25m, and 60m along the 60m tower.

  15. Reactivity of stratospheric aerosols to small amounts of ammonia in the laboratory environment

    NASA Technical Reports Server (NTRS)

    Hayes, D.; Snetsinger, K.; Ferry, G.; Oberbeck, V.; Farlow, N.

    1980-01-01

    Trace ammonia in laboratory air reacts easily with sulfuric acid aerosol samples to form crystalline ammonium sulfate. Argon atmospheres, however, protect sampling surfaces from ammonia contamination. It is found that atmospheric aerosols treated in this way contain only sulfuric acid. After an hour exposed to laboratory air, these same samples convert to ammonium sulfate. Aerosol particles have been collected, using argon control, to determine if the absence of crystalline sulfate is common. But so far there is no evidence that aerosols are neutralized by ammonia in the stratosphere.

  16. Microbial Safari.

    ERIC Educational Resources Information Center

    Wagner, Stephen C.; Stewart, Robert S., Jr.

    2000-01-01

    Introduces an investigative microbiology laboratory activity emphasizing critical thinking and experimental design in which students isolate and characterize a bacterium from a specific habitat. Explains the procedures of the laboratory including safety, sample collection, and isolation. (YDS)

  17. Tank 30 and 37 Supernatant Sample Cross-Check and Evaporator Feed Qualification Analysis-2012

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oji, L. N.

    2013-03-07

    This report summarizes the analytical data reported by the F/H and Savannah River National Laboratories for the 2012 cross-check analysis for high level waste supernatant liquid samples from SRS Tanks 30 and 37. The intent of this Tank 30 and 37 sample analyses was to perform cross-checks against routine F/H Laboratory analyses (corrosion and evaporator feed qualification programs) using samples collected at the same time from both tanks as well as split samples from the tanks.

  18. A New Paradigm for Tissue Diagnostics: Tools and Techniques to Standardize Tissue Collection, Transport, and Fixation.

    PubMed

    Bauer, Daniel R; Otter, Michael; Chafin, David R

    2018-01-01

    Studying and developing preanalytical tools and technologies for the purpose of obtaining high-quality samples for histological assays is a growing field. Currently, there does not exist a standard practice for collecting, fixing, and monitoring these precious samples. There has been some advancement in standardizing collection for the highest profile tumor types, such as breast, where HER2 testing drives therapeutic decisions. This review examines the area of tissue collection, transport, and monitoring of formalin diffusion and details a prototype system that could be used to help standardize tissue collection efforts. We have surveyed recent primary literature sources and conducted several site visits to understand the most error-prone processes in histology laboratories. This effort identified errors that resulted from sample collection techniques and subsequent transport delays from the operating room (OR) to the histology laboratories. We have therefore devised a prototype sample collection and transport concept. The system consists of a custom data logger and cold transport box and takes advantage of a novel cold + warm (named 2 + 2) fixation method. This review highlights the beneficial aspects of standardizing tissue collection, fixation, and monitoring. In addition, a prototype system is introduced that could help standardize these processes and is compatible with use directly in the OR and from remote sites.

  19. Use of an ultra-clean sampling technique with inductively coupled plasma-mass spectrometry to determine trace-element concentrations in water from the Kirkwood-Cohansey Aquifer system, coastal plain, New Jersey

    USGS Publications Warehouse

    Ivahnenko, Tamara; Szabo, Zoltan; Hall, G.S.

    1996-01-01

    Water samples were collected during 1993 from 22 public supply wells screened in the Kirkwood-Cohansey aquifer system; concentrations of 18 trace elements were determined primarily by using inductively coupled plasma-mass spectrometry (ICP-MS) techniques, though graphite furnace atomic adsorption, hydride generation, and cold- vapor flameless atomic adsorption techniques were used for thallium, arsenic, and mercury, respectively, at the U.S. Geological Survey (USGS) National Water Quality Laboratory (NWQL). In addition, laboratory measurements of alkalinity and turbidity were made. The ground-water samples were collected by using ultra-clean sampling protocols developed by the USGS for collecting ground-water samples in areas with water containing low concentrations of trace elements. This technique is based on recently gained experience in sampling surface water for these elements. Field parameters (water temperature, specific conductance, pH, and dissolved-oxygen concentration) were monitored prior to sample collection. Three equipment blanks were collected to ensure that low-level trace-element contamination did not occur during sample collection. One split sample and a commercially- prepared reference standard were submitted to the NWQL o evaluate laboratory precision and accuracy, respectively. Trace-element concentrations in 10 sample splits and one equipment blank were also determined at the Rutgers University Chemistry Department laboratory. Results of the ICP-MS analyses and cold vapor flameless atomic absorption indicated that five trace elements-- cobalt, copper, lead, mercury, and nickel--were detectable in low concentrations (<0.1-29 mg/L) in most of the samples from the 22 wells, and four elements--aluminum, barium, manganese and zinc--were detected in higher concentrations than the other elements (30-710 mg/L for aluminum; 4-180 mg/L for barium, manganese, and zinc). The remaining nine trace elements were present in concentrations consistently lower than the minimum reporting limit. Turbidity was low (less than 1 nephelometric turbidity unit (NTU)), indicating that the trace-element concentrations were present in the dissolved phase and ideally would be reproducible in the absence of highly variable concentrations of particulates. The concentration of lead in one sample exceeded the U.S. Environmental Protection Agency (USEPA) action level of 15 mg/L; concentrations ranged from <1 to 16 mg/L. Mercury was frequently detected; concentrations ranged from <0.1 to 1.1 mg/L but did not exceed the USEPA maximum contaminant level. Results of analyses of the equipment blanks indicated that samples collected by using the new ultra-clean sampling protocols were free of low-level (< 1mg/L) trace-element contamination. The analysis of the split sample sent to the NWQL had a difference of 5 percent or less for all constituents except aluminum, for which the analysis had a difference of 10 percent. Results of ICP-MS analyses of split water samples sent to the Rutgers University Chemistry Department laboratory were, in general, in good agreement (within 10 percent) with those of the NWQL. Results of the analysis of the commercial standard agreed (within 5 percent) with the known concentrations of the trace elements. The quality-assurance data (three blanks, one split sample, and one standard), although not statistically evaluated because of the small data set, indicate that the measured trace-element concentrations are precise and accurate and that the samples were free of contamination at the microgram-per-liter level of contamination.

  20. [Application of laboratory information system in the management of the key indicators of quality inspection].

    PubMed

    Guo, Ye; Chen, Qian; Wu, Wei; Cui, Wei

    2015-03-31

    To establish a system of monitoring the key indicator of quality for inspection (KIQI) on a laboratory information system (LIS), and to have a better management of KIQI. Clinical sample made in PUMCH were collected during the whole of 2014. Next, interactive input program were designed to accomplish data collecting of the disqualification rate of samples, the mistake rate of samples and the occasions of losing samples, etc. Then, a series moment of sample collection, laboratory sample arrived, sample test, sample check, response to critical value, namely, trajectory information left on LIS were recorded and the qualification rate of TAT, the notification rate of endangering result were calculated. Finally, the information about quality control were collected to build an internal quality control database and the KIQI, such as the out-of-control rate of quality control and the total error of test items were monitored. The inspection of the sample management shows the disqualification rates in 2014 were all below the target, but the rates in January and February were a little high and the rates of four wards were above 2%. The mistake rates of samples was 0.47 cases/10 000 cases, attaining the target (< 2 cases/10 000 cases). Also, there was no occasion of losing samples in 2014, attaining the target too. The inspection of laboratory reports shows the qualification rates of TAT was within the acceptable range (> 95%), however the rates of blood routine in November (94.75%) was out of range. We have solved the problem by optimizing the processes. The notification rate of endangering result attained the target (≥ 98%), while the rate of timely notification is needed to improve. Quality inspection shows the CV of APTT in August (5.02%) was rising significantly, beyond the accepted CV (5.0%). We have solved the problem by changing the reagent. The CV of TT in 2014 were all below the allowable CV, thus the allowable CV of the next year lower to 10%. It is an objective and effective method to manage KIQI with the powerful management mode of database and information process capability on LIS.

  1. Evaluation of field sampling and preservation methods for strontium-90 in ground water at the Idaho National Engineering Laboratory, Idaho

    USGS Publications Warehouse

    Cecil, L.D.; Knobel, L.L.; Wegner, S.J.; Moore, L.L.

    1989-01-01

    Water from four wells completed in the Snake River Plain aquifer was sampled as part of the U.S. Geological Survey 's quality assurance program to evaluate the effect of filtration and preservation methods on strontium-90 concentrations in groundwater at the Idaho National Engineering Laboratory. Water from each well was filtered through either a 0.45-micrometer membrane or a 0.1-micrometer membrane filter; unfiltered samples also were collected. Two sets of filtered and two sets of unfiltered samples was preserved in the field with reagent-grade hydrochloric acid and the other set of samples was not acidified. For water from wells with strontium-90 concentrations at or above the reporting level, 94% or more of the strontium-90 is in true solution or in colloidal particles smaller than 0.1 micrometer. These results suggest that within-laboratory reproducibility for strontium-90 in groundwater at the INEL is not significantly affected by changes in filtration and preservation methods used for sample collections. (USGS)

  2. Evaluation of field sampling and preservation methods for strontium-90 in ground water at the Idaho National Engineering Laboratory, Idaho

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cecil, L.D.; Knobel, L.L.; Wegner, S.J.

    1989-01-01

    Water from four wells completed in the Snake River Plain aquifer was sampled as part of the US Geological Survey's quality assurance program to evaluate the effect of filtration and preservation methods on strontium-90 concentrations in groundwater at the Idaho National Engineering Laboratory. Water from each well was filtered through either a 0.45-micrometer membrane or a 0.1-micrometer membrane filter; unfiltered samples also were collected. Two sets of filtered and two sets of unfiltered samples was preserved in the field with reagent-grade hydrochloric acid and the other set of samples was not acidified. For water from wells with strontium-90 concentrations atmore » or above the reporting level, 94% or more of the strontium-90 is in true solution or in colloidal particles smaller than 0.1 micrometer. These results suggest that within-laboratory reproducibility for strontium-90 in groundwater at the INEL is not significantly affected by changes in filtration and preservation methods used for sample collections. 13 refs., 2 figs., 6 tabs.« less

  3. Laboratory surveillance for wild and vaccine-derived polioviruses, January 2004-June 2005.

    PubMed

    2005-09-30

    A global network of 145 virology laboratories has been established by the World Health Organization (WHO) to support surveillance activities of the Polio Eradication Initiative (PEI). The Global Polio Laboratory Network analyzes stool specimens from patients with acute flaccid paralysis (AFP) and environmental samples for the presence of polioviruses. Surveillance systems detect at least one AFP case per 100,000 persons aged <15 years, collect adequate stool samples from patients, and send the samples to network laboratories for analysis. Laboratory data are used to identify locations where wild polioviruses (WPVs) or vaccine-derived polioviruses (VDPVs) are circulating, target supplementary immunization activities (SIAs) to interrupt transmission chains, and investigate genetic relationships among viral isolates. This report updates previous publications and describes the laboratory network's performance during the period January 2004-June 2005.

  4. Geotechnical characterization of mined clay from Appalachian Ohio: challenges and implications for the clay mining industry.

    PubMed

    Moran, Anthony R; Hettiarachchi, Hiroshan

    2011-07-01

    Clayey soil found in coal mines in Appalachian Ohio is often sold to landfills for constructing Recompacted Soil Liners (RSL) in landfills. Since clayey soils possess low hydraulic conductivity, the suitability of mined clay for RSL in Ohio is first assessed by determining its clay content. When soil samples are tested in a laboratory, the same engineering properties are typically expected for the soils originated from the same source, provided that the testing techniques applied are standard, but mined clay from Appalachian Ohio has shown drastic differences in particle size distribution depending on the sampling and/or laboratory processing methods. Sometimes more than a 10 percent decrease in the clay content is observed in the samples collected at the stockpiles, compared to those collected through reverse circulation drilling. This discrepancy poses a challenge to geotechnical engineers who work on the prequalification process of RSL material as it can result in misleading estimates of the hydraulic conductivity of the samples. This paper describes a laboratory investigation conducted on mined clay from Appalachian Ohio to determine how and why the standard sampling and/or processing methods can affect the grain-size distributions. The variation in the clay content was determined to be due to heavy concentrations of shale fragments in the clayey soils. It was also concluded that, in order to obtain reliable grain size distributions from the samples collected at a stockpile of mined clay, the material needs to be processed using a soil grinder. Otherwise, the samples should be collected through drilling.

  5. Geotechnical Characterization of Mined Clay from Appalachian Ohio: Challenges and Implications for the Clay Mining Industry

    PubMed Central

    Moran, Anthony R.; Hettiarachchi, Hiroshan

    2011-01-01

    Clayey soil found in coal mines in Appalachian Ohio is often sold to landfills for constructing Recompacted Soil Liners (RSL) in landfills. Since clayey soils possess low hydraulic conductivity, the suitability of mined clay for RSL in Ohio is first assessed by determining its clay content. When soil samples are tested in a laboratory, the same engineering properties are typically expected for the soils originated from the same source, provided that the testing techniques applied are standard, but mined clay from Appalachian Ohio has shown drastic differences in particle size distribution depending on the sampling and/or laboratory processing methods. Sometimes more than a 10 percent decrease in the clay content is observed in the samples collected at the stockpiles, compared to those collected through reverse circulation drilling. This discrepancy poses a challenge to geotechnical engineers who work on the prequalification process of RSL material as it can result in misleading estimates of the hydraulic conductivity of the samples. This paper describes a laboratory investigation conducted on mined clay from Appalachian Ohio to determine how and why the standard sampling and/or processing methods can affect the grain-size distributions. The variation in the clay content was determined to be due to heavy concentrations of shale fragments in the clayey soils. It was also concluded that, in order to obtain reliable grain size distributions from the samples collected at a stockpile of mined clay, the material needs to be processed using a soil grinder. Otherwise, the samples should be collected through drilling. PMID:21845150

  6. Water Quality & Pollutant Source Monitoring: Field and Laboratory Procedures. Training Manual.

    ERIC Educational Resources Information Center

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This training manual presents material on techniques and instrumentation used to develop data in field monitoring programs and related laboratory operations concerned with water quality and pollution monitoring. Topics include: collection and handling of samples; bacteriological, biological, and chemical field and laboratory methods; field…

  7. The forensiX evidence collection tube and its impact on DNA preservation and recovery.

    PubMed

    Garvin, Alex M; Holzinger, Ralf; Berner, Florian; Krebs, Walter; Hostettler, Bernhard; Lardi, Elges; Hertli, Christian; Quartermaine, Roy; Stamm, Christoph

    2013-01-01

    Biological samples are vulnerable to degradation from the time they are collected until they are analysed at the laboratory. Biological contaminants, such as bacteria, fungi, and enzymes, as well as environmental factors, such as sunlight, heat, and humidity, can increase the rate of DNA degradation. Currently, DNA samples are normally dried or frozen to limit their degradation prior to their arrival at the laboratory. In this study, the effect of the sample drying rate on DNA preservation was investigated, as well as a comparison between drying and freezing methods. The drying performances of two commercially available DNA collection tools (swab and drying tube) with different drying rates were evaluated. The swabs were used to collect human saliva, placed into the drying tubes, and stored in a controlled environment at 25°C and 60% relative humidity, or frozen at -20°C, for 2 weeks. Swabs that were stored in fast sample drying tubes yielded 95% recoverable DNA, whereas swabs stored in tubes with slower sample drying rates yielded only 12% recoverable DNA; saliva stored in a microtube at -20°C was used as a control. Thus, DNA sampling tools that offer rapid drying can significantly improve the preservation of DNA collected on a swab, increasing the quantity of DNA available for subsequent analysis.

  8. RECOMMENDED OPERATING PROCEDURE NO. 56: COLLECTION OF GASEOUS GRAB SAMPLES FROM COMBUSTION SOURCES FOR NITROUS OXIDE MEASUREMENT

    EPA Science Inventory

    The document is a recommended operating procedure, prepare or use in research activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). The procedure applies to the collection of gaseous grab samples from fossil fuel combustion sources for subsequent a...

  9. PCB Content of Sediments Collected at Manistique Harbor, Michigan

    DTIC Science & Technology

    2014-06-01

    2013 10:19 PM Page 23 of 35 Date Reported: 1/24/2013 Original WO#: 1211282RTI Laboratories - DATES REPORT Leachate Date USACE- Detroit District...REPORT Leachate Date USACE- Detroit District Manistique Harbor 0004 Client: Project: Sample ID Test NameMatrixCollection DateClient Sample ID Analysis

  10. Soil Sampling Operating Procedure

    EPA Pesticide Factsheets

    EPA Region 4 Science and Ecosystem Support Division (SESD) document that describes general and specific procedures, methods, and considerations when collecting soil samples for field screening or laboratory analysis.

  11. Sediment Sampling Operating Procedure

    EPA Pesticide Factsheets

    EPA Region 4 Science and Ecosystem Support Division (SESD) document that describes general and specific procedures, methods, and considerations when collecting sediment samples for field screening or laboratory analysis.

  12. ACQUISITION OF REPRESENTATIVE GROUND WATER QUALITY SAMPLES FOR METALS

    EPA Science Inventory

    R.S. Kerr Environmental Research Laboratory (RSKERL) personnel have evaluated sampling procedures for the collection of representative, accurate, and reproducible ground water quality samples for metals for the past four years. Intensive sampling research at three different field...

  13. Evolved Gas Analysis and X-Ray Diffraction of Carbonate Samples from the 2009 Arctic Mars Analog Svalbard Expedition: Implications for Mineralogical Inferences from the Mars Science Laboratory

    NASA Technical Reports Server (NTRS)

    McAdam, A. C.; Mahaffy, P. R.; Blake, D. F.; Ming, D. W.; Franz, H. B.; Eigenbrode, J. L.; Steele, A.

    2010-01-01

    The 2009 Arctic Mars Analog Svalbard Expedition (AMASE) investigated several geologic settings using methodologies and techniques being developed or considered for future Mars missions, such as the Mars Science Laboratory (MSL), ExoMars, and Mars Sample Return (MSR). AMASE-related research comprises both analyses conducted during the expedition and further analyses of collected samples using laboratory facilities at a variety of institutions. The Sample Analysis at Mars (SAM) instrument suite, which will be part of the Analytical Laboratory on MSL, consists of a quadrupole mass spectrometer (QMS), a gas chromatograph (GC), and a tunable laser spectrometer (TLS). An Evolved Gas Analysis Mass Spectrometer (EGA-MS) was used during AMASE to represent part of the capabilities of SAM. The other instrument included in the MSL Analytical Laboratory is CheMin, which uses X-Ray Diffraction (XRD) and X-Ray Fluorescence (XRF) to perform quantitative mineralogical characterization of samples. Field-portable versions of CheMin were used during the AMASE 2009. Here, we discuss the preliminary interpretation of EGA and XRD analyses of selected AMASE carbonate samples and implications for mineralogical interpretations from MSL. Though CheMin will be the primary mineralogical tool on MSL, SAM EGA could be used to support XRD identifications or indicate the presence of volatile-bearing minerals which may be near or below XRD detection limits. Data collected with instruments in the field and in comparable laboratory setups (e.g., the SAM breadboard) will be discussed.

  14. DEVELOPMENT OF A TAMPER RESISTANT/INDICATING AEROSOL COLLECTION SYSTEM FOR ENVIRONMENTAL SAMPLING AT BULK HANDLING FACILITIES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sexton, L.

    2012-06-06

    Environmental sampling has become a key component of International Atomic Energy Agency (IAEA) safeguards approaches since its approval for use in 1996. Environmental sampling supports the IAEA's mission of drawing conclusions concerning the absence of undeclared nuclear material or nuclear activities in a Nation State. Swipe sampling is the most commonly used method for the collection of environmental samples from bulk handling facilities. However, augmenting swipe samples with an air monitoring system, which could continuously draw samples from the environment of bulk handling facilities, could improve the possibility of the detection of undeclared activities. Continuous sampling offers the opportunity tomore » collect airborne materials before they settle onto surfaces which can be decontaminated, taken into existing duct work, filtered by plant ventilation, or escape via alternate pathways (i.e. drains, doors). Researchers at the Savannah River National Laboratory and Oak Ridge National Laboratory have been working to further develop an aerosol collection technology that could be installed at IAEA safeguarded bulk handling facilities. The addition of this technology may reduce the number of IAEA inspector visits required to effectively collect samples. The principal sample collection device is a patented Aerosol Contaminant Extractor (ACE) which utilizes electrostatic precipitation principles to deposit particulates onto selected substrates. Recent work has focused on comparing traditional swipe sampling to samples collected via an ACE system, and incorporating tamper resistant and tamper indicating (TRI) technologies into the ACE system. Development of a TRI-ACE system would allow collection of samples at uranium/plutonium bulk handling facilities in a manner that ensures sample integrity and could be an important addition to the international nuclear safeguards inspector's toolkit. This work was supported by the Next Generation Safeguards Initiative (NGSI), Office of Nonproliferation and International Security (NIS), National Nuclear Security Administration (NNSA).« less

  15. A quality-assurance assessment for constituents reported by the national atmospheric deposition program and the national trends network

    NASA Astrophysics Data System (ADS)

    See, Randolph B.; Schroder, LeRoy J.; Willoughby, Timothy C.

    A continuing quality-assurance program has been operated by the U.S. Geological Survey to evaluate any bias introduced by routine handling, shipping, and laboratory analyses of wet-deposition samples collected in the National Atmospheric Deposition Program (NADP) and National Trends Network (NTN). Blind-audit samples having a variety of constituent concentrations and values were selected. Only blind-audit samples with constituent concentrations and values less than the 95th-percentile concentration for natural wet-deposition samples were included in the analysis. Of the major ions, there was a significant increase of Ca 2+, Mg 2+, Na 2+, K +, SO 42- and Cl -1 in samples handled according to standard protocols and shipped in NADP/NTN sample-collection buckets. For 1979-1987, graphs of smoothed data showing the estimated contamination in blind-audit samples indicate a decrease in the median concentration and ranges of Ca 2+, Mg 2+ and SO 42- contamination of blind-audit samples shipped in sample-collection buckets. Part of the contamination detected in blind-audit samples can be attributed to contact with the sample-collection bucket and lid; however, additional sources also seem to contaminate the blind-audit sample. Apparent decreases in the magnitude and range of sample contamination may be caused by differences in sample-collection bucket- and lid-washing procedures by the NADP/NTN Central Analytical Laboratory. Although the degree of bias is minimal for most constituents, summaries of the NADP/NTN data base may contain overestimates of Ca 2+, Mg 2+, Na -, K + and SO 42- and Cl - concentrations, and underestimates of H + concentrations.

  16. A quality-assurance assessment for constituents reported by the National Atmospheric Deposition Program and the National Trends Network

    USGS Publications Warehouse

    See, R.B.; Schroder, L.J.; Willoughby, T.C.

    1989-01-01

    A continuing quality-assurance program has been operated by the U.S. Geographical Survey to evaluate any bias introduced by routine handling, shipping, and laboratory analyses of wet-deposition samples collected in the National Atmospheric Deposition Program (NADP) and National Trends Network (NTN). Blind-audit samples having a variety of constituent concentrations and values were selected. Only blind-audit samples with constituent concentrations and values less than the 95th-percentile concentration for natural wet-deposition samples were included in the analysis. Of the major ions, there was a significant increase of Ca2+, Mg2+, K+ SO42+ and Cl- in samples handled according to standard protocols and shipped in NADP/NTN sample-collection buckets. For 1979-1987, graphs of smoothed data showing the estimated contaminations in blind-audit samples indicate a decrease in the median concentration and ranges of Ca2+, Mg2+ and SO42- contamination of blind-audit samples shipped in sample-collection buckets. Part of the contamination detected in blind-audit samples can be attributed to contact with the sample-collection bucket and lid; however, additional sources also seem to contaminate the blind-audit sample. Apparent decreases in the magnitude and range of sample contamination may be caused by differences in sample-collection bucket- and lid-washing procedures by the NADP/NTN Central Analytical Laboratory. Although the degree of bias is minimal for most constituents, summaries of the NADP/NTN data base may contain overestimates of Ca2+, Mg2+, Na-, K+, SO42- and Cl- concentrations, and underestimates of H+ concentrations.

  17. Chemical analyses in the World Coal Quality Inventory

    USGS Publications Warehouse

    Tewalt, Susan J.; Belkin, Harvey E.; SanFilipo, John R.; Merrill, Matthew D.; Palmer, Curtis A.; Warwick, Peter D.; Karlsen, Alexander W.; Finkelman, Robert B.; Park, Andy J.

    2010-01-01

    The main objective of the World Coal Quality Inventory (WoCQI) was to collect and analyze a global set of samples of mined coal during a time period from about 1995 to 2006 (Finkelman and Lovern, 2001). Coal samples were collected by foreign collaborators and submitted to country specialists in the U.S. Geological Survey (USGS) Energy Program. However, samples from certain countries, such as Afghanistan, India, and Kyrgyzstan, were collected collaboratively in the field with USGS personnel. Samples were subsequently analyzed at two laboratories: the USGS Inorganic Geochemistry Laboratory located in Denver, CO and a commercial laboratory (Geochemical Testing, Inc.) located in Somerset, PA. Thus the dataset, which is in Excel (2003) format and includes 1,580 samples from 57 countries, does not have the inter-laboratory variability that is present in many compilations. Major-, minor-, and trace-element analyses from the USGS laboratory, calculated to a consistent analytical basis (dry, whole-coal) and presented with available sample identification information, are sorted alphabetically by country name. About 70 percent of the samples also have data from the commercial laboratory, which are presented on an as-received analytical basis. The USGS initiated a laboratory review of quality assurance in 2008, covering quality control and methodology used in inorganic chemical analyses of coal, coal power plant ash, water, and sediment samples. This quality control review found that data generated by the USGS Inorganic Geochemistry Laboratory from 1996 through 2006 were characterized by quality practices that did not meet USGS requirements commonly in use at the time. The most serious shortcomings were (1) the adjustment of raw sample data to standards when the instrument values for those standards exceeded acceptable limits or (2) the insufficient use of multiple standards to provide adequate quality assurance. In general, adjustment of raw data to account for instrument 'drift' is an acceptable practice within strictly defined limits. During the denoted period, USGS required that the maximum adjustment of instrument values, guided by calibration standards, was not allowed to exceed 10 percent. However, in some cases, the Inorganic Geochemistry Laboratory released data that were adjusted by more than 10 percent and (or) were not constrained by an adequate number of control standards. Original instrument values no longer exist for about 80 percent of the analyses during this period; therefore, the acceptability of drift corrections for most of the samples analyzed cannot be determined. For these reasons, the WoCQI data from the USGS Inorganic Geochemistry Laboratory should be used with care. For more information, individuals may contact laboratory management at EnergyLabs@usgs.gov with specific questions about particular datasets or analytical attributes. Standard USGS sampling methods were provided and recommended to collaborators, but the analyzed samples may or may not be representative of their locale; for some samples, only limited information is available concerning sample provenance. Single samples cannot represent spatial or temporal variability within a coal area. Geochemical datasets of U.S. coals can be found in the COALQUAL database (Bragg and others, 1997) and the National Coal Quality Inventory (Hatch and others, 2006), as only non-U.S. sample data are presented in the WoCQI. Although the WoCQI does not contain worldwide coverage of coal deposits, it is truly a unique and valuable compilation. The information in the WoCQI should prove useful for identifying possible areas for future global coal research.

  18. Evaluation of Quality-Assurance/Quality-Control Data Collected by the U.S. Geological Survey from Wells and Springs between the Southern Boundary of the Idaho National Engineering and Environmental Laboratory and the Hagerman Area, Idaho, 1989 through 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, L.M.; Bartholomay, R.C.; Campbell, L.J.

    1998-10-01

    The U.S. Geological (USGS) and the Idaho Department of Water Resources, in cooperation with the U.S. Department of Energy, collected and analyzed water samples to monitor the water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering and Environmental Laboratory to the Hagerman area, Idaho. Concurrently, replicate samples and blank samples were collected and analyzed as part of the quality-assurance/quality-control program. Samples were analyzed from inorganic constituents, gross radioactivity and radionuclides, organic constituents, and stable isotopes. To evaluate the precision of field and laboratory methods, analytical results of the water-quality and replicate samplesmore » were compared statistically for equivalence on the basis of the precision associated with each result. Statistical comparisons of the data indicated that 95 percent of the results of the replicate pairs were equivalent. Blank-sample analytical results indicated th at the inorganic blank water and volatile organic compound blank water from the USGS National Water Quality Laboratory and the distilled water from the Idaho Department of Water Resources were suitable for blanks; blank water from other sources was not. Equipment-blank analytical results were evaluated to determine if a bias had been introduced and possible sources of bias. Most equipment blanks were analyzed for trace elements and volatile organic compounds; chloroform was found in one equipment blank. Two of the equipment blanks were prepared after collection and analyses of the water-quality samples to determine whether contamination had been introduced during the sampling process. Results of one blank indicated that a hose used to divert water away from pumps and electrical equipment had contaminated the samples with some volatile organic compounds. Results of the other equipment blank, from the apparatus used to filter dissolved organic carbon samples, indicated that the filtering apparatus did not affect water-quality samples.« less

  19. Plasma creatinine in dogs: intra- and inter-laboratory variation in 10 European veterinary laboratories

    PubMed Central

    2011-01-01

    Background There is substantial variation in reported reference intervals for canine plasma creatinine among veterinary laboratories, thereby influencing the clinical assessment of analytical results. The aims of the study was to determine the inter- and intra-laboratory variation in plasma creatinine among 10 veterinary laboratories, and to compare results from each laboratory with the upper limit of its reference interval. Methods Samples were collected from 10 healthy dogs, 10 dogs with expected intermediate plasma creatinine concentrations, and 10 dogs with azotemia. Overlap was observed for the first two groups. The 30 samples were divided into 3 batches and shipped in random order by postal delivery for plasma creatinine determination. Statistical testing was performed in accordance with ISO standard methodology. Results Inter- and intra-laboratory variation was clinically acceptable as plasma creatinine values for most samples were usually of the same magnitude. A few extreme outliers caused three laboratories to fail statistical testing for consistency. Laboratory sample means above or below the overall sample mean, did not unequivocally reflect high or low reference intervals in that laboratory. Conclusions In spite of close analytical results, further standardization among laboratories is warranted. The discrepant reference intervals seem to largely reflect different populations used in establishing the reference intervals, rather than analytical variation due to different laboratory methods. PMID:21477356

  20. BRDF of Salt Pan Regolith Samples

    NASA Technical Reports Server (NTRS)

    Georgiev, Georgi T.; Gatebe, Charles K.; Butler, James J.; King, Michael D.

    2008-01-01

    Laboratory Bi-directional Reflectance Distribution Function (BRDF) measurements of salt pan regolith samples are presented in this study in an effort to understand the role of spatial and spectral variability of the natural biome. The samples were obtained from Etosha Pan, Namibia (19.20 deg S, 15.93 deg E, alt. 1100 m). It is shown how the BRDF depends on the measurement geometry - incident and scatter angles and on the sample particle sizes. As a demonstration of the application of the results, airborne BRDF measurements acquires with NASA's Cloud Absorption Radiometer (CAR) over the same general site where the regolith samples were collected are compared with the laboratory results. Good agreement between laboratory measured and field measured BRDF is reported.

  1. Evaluation of Two Surface Sampling Methods for Detection of Erwinia herbicola on a Variety of Materials by Culture and Quantitative PCR▿

    PubMed Central

    Buttner, Mark P.; Cruz, Patricia; Stetzenbach, Linda D.; Cronin, Tracy

    2007-01-01

    This research was designed to evaluate surface sampling protocols for use with culture and quantitative PCR (QPCR) amplification assay for detection of the gram-negative bacterial biothreat simulant Erwinia herbicola on a variety of surface materials. Surfaces selected for evaluation were wood laminate, glass and computer monitor screens, metal file cabinets, plastic arena seats, nylon seat cushions, finished concrete flooring, and vinyl tile flooring. Laboratory and test chamber studies were performed to evaluate two sampling methods, a sponge and a macrofoam swab, for detection of E. herbicola on surface materials. In laboratory trials, seven materials were inoculated with a known concentration of E. herbicola cells and samples were collected from the surfaces of the materials to determine sampling efficiencies. Culture analysis was ineffective for assessing E. herbicola collection efficiency because very few culturable cells were obtained from surface samples. QPCR demonstrated that E. herbicola DNA was present in high concentrations on all of the surface samples, and sampling efficiencies ranged from 0.7 to 52.2%, depending on the sampling method and the surface material. The swab was generally more efficient than the sponge for collection of E. herbicola from surfaces. Test chamber trials were also performed in which E. herbicola was aerosolized into the chamber and allowed to settle onto test materials. Surface sampling results supported those obtained in laboratory trials. The results of this study demonstrate the capabilities of QPCR to enhance the detection and enumeration of biocontaminants on surface materials and provide information on the comparability of sampling methods. PMID:17416685

  2. Evaluation of two surface sampling methods for detection of Erwinia herbicola on a variety of materials by culture and quantitative PCR.

    PubMed

    Buttner, Mark P; Cruz, Patricia; Stetzenbach, Linda D; Cronin, Tracy

    2007-06-01

    This research was designed to evaluate surface sampling protocols for use with culture and quantitative PCR (QPCR) amplification assay for detection of the gram-negative bacterial biothreat simulant Erwinia herbicola on a variety of surface materials. Surfaces selected for evaluation were wood laminate, glass and computer monitor screens, metal file cabinets, plastic arena seats, nylon seat cushions, finished concrete flooring, and vinyl tile flooring. Laboratory and test chamber studies were performed to evaluate two sampling methods, a sponge and a macrofoam swab, for detection of E. herbicola on surface materials. In laboratory trials, seven materials were inoculated with a known concentration of E. herbicola cells and samples were collected from the surfaces of the materials to determine sampling efficiencies. Culture analysis was ineffective for assessing E. herbicola collection efficiency because very few culturable cells were obtained from surface samples. QPCR demonstrated that E. herbicola DNA was present in high concentrations on all of the surface samples, and sampling efficiencies ranged from 0.7 to 52.2%, depending on the sampling method and the surface material. The swab was generally more efficient than the sponge for collection of E. herbicola from surfaces. Test chamber trials were also performed in which E. herbicola was aerosolized into the chamber and allowed to settle onto test materials. Surface sampling results supported those obtained in laboratory trials. The results of this study demonstrate the capabilities of QPCR to enhance the detection and enumeration of biocontaminants on surface materials and provide information on the comparability of sampling methods.

  3. A comparison of two laboratories for the measurement of wood dust using button sampler and diffuse reflection infrared Fourier-transform spectroscopy (DRIFTS).

    PubMed

    Chirila, Madalina M; Sarkisian, Khachatur; Andrew, Michael E; Kwon, Cheol-Woong; Rando, Roy J; Harper, Martin

    2015-04-01

    The current measurement method for occupational exposure to wood dust is by gravimetric analysis and is thus non-specific. In this work, diffuse reflection infrared Fourier transform spectroscopy (DRIFTS) for the analysis of only the wood component of dust was further evaluated by analysis of the same samples between two laboratories. Field samples were collected from six wood product factories using 25-mm glass fiber filters with the Button aerosol sampler. Gravimetric mass was determined in one laboratory by weighing the filters before and after aerosol collection. Diffuse reflection mid-infrared spectra were obtained from the wood dust on the filter which is placed on a motorized stage inside the spectrometer. The metric used for the DRIFTS analysis was the intensity of the carbonyl band in cellulose and hemicellulose at ~1735 cm(-1). Calibration curves were constructed separately in both laboratories using the same sets of prepared filters from the inhalable sampling fraction of red oak, southern yellow pine, and western red cedar in the range of 0.125-4 mg of wood dust. Using the same procedure in both laboratories to build the calibration curve and analyze the field samples, 62.3% of the samples measured within 25% of the average result with a mean difference between the laboratories of 18.5%. Some observations are included as to how the calibration and analysis can be improved. In particular, determining the wood type on each sample to allow matching to the most appropriate calibration increases the apparent proportion of wood dust in the sample and this likely provides more realistic DRIFTS results. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2014.

  4. Chemistry Testing on Plasma Versus Serum Samples in Dialysis Patients: Clinical and Quality Improvement Implications.

    PubMed

    Carey, Roger Neill; Jani, Chinu; Johnson, Curtis; Pearce, Jim; Hui-Ng, Patricia; Lacson, Eduardo

    2016-09-07

    Plasma samples collected in tubes containing separator gels have replaced serum samples for most chemistry tests in many hospital and commercial laboratories. Use of plasma samples for blood tests in the dialysis population eliminates delays in sample processing while waiting for clotting to complete, laboratory technical issues associated with fibrin formation, repeat sample collection, and patient care issues caused by delay of results because of incompletely clotted specimens. Additionally, a larger volume of plasma is produced than serum for the same amount of blood collected. Plasma samples are also acceptable for most chemical tests involved in the care of patients with ESRD. This information becomes very important when United States regulatory requirements for ESRD inadvertently limit the type of sample that can be used for government reporting, quality assessment, and value-based payment initiatives. In this narrative, we summarize the renal community experience and how the subsequent resolution of the acceptability of phosphorus levels measured from serum and plasma samples may have significant implications in the country's continued development of a value-based Medicare ESRD Quality Incentive Program. Copyright © 2016 by the American Society of Nephrology.

  5. Soil Gas Sampling Operating Procedure

    EPA Pesticide Factsheets

    EPA Region 4 Science and Ecosystem Support Division (SESD) document that describes general and specific procedures, methods, and considerations when collecting soil gas samples for field screening or laboratory analysis.

  6. Comparison of PIXE and XRF analysis of airborne particulate matter samples collected on Teflon and quartz fibre filters

    NASA Astrophysics Data System (ADS)

    Chiari, M.; Yubero, E.; Calzolai, G.; Lucarelli, F.; Crespo, J.; Galindo, N.; Nicolás, J. F.; Giannoni, M.; Nava, S.

    2018-02-01

    Within the framework of research projects focusing on the sampling and analysis of airborne particulate matter, Particle Induced X-ray Emission (PIXE) and Energy Dispersive X-ray Fluorescence (ED-XRF) techniques are routinely used in many laboratories throughout the world to determine the elemental concentration of the particulate matter samples. In this work an inter-laboratory comparison of the results obtained from analysing several samples (collected on both Teflon and quartz fibre filters) using both techniques is presented. The samples were analysed by PIXE (in Florence, at the 3 MV Tandetron accelerator of INFN-LABEC laboratory) and by XRF (in Elche, using the ARL Quant'X EDXRF spectrometer with specific conditions optimized for specific groups of elements). The results from the two sets of measurements are in good agreement for all the analysed samples, thus validating the use of the ARL Quant'X EDXRF spectrometer and the selected measurement protocol for the analysis of aerosol samples. Moreover, thanks to the comparison of PIXE and XRF results on Teflon and quartz fibre filters, possible self-absorption effects due to the penetration of the aerosol particles inside the quartz fibre-filters were quantified.

  7. Large-Scale Variability of Inpatient Tacrolimus Therapeutic Drug Monitoring at an Academic Transplant Center: a Retrospective Study.

    PubMed

    Strohbehn, Garth W; Pan, Warren W; Petrilli, Christopher M; Heidemann, Lauren; Larson, Sophia; Aaronson, Keith D; Johnson, Matt; Ellies, Tammy; Heung, Michael

    2018-04-30

    Inpatient tacrolimus therapeutic drug monitoring (TDM) lacks standardized guidelines. In this study, the authors analyzed variability in the pre-analytical phase of the inpatient tacrolimus TDM process at their institution. Patients receiving tacrolimus (twice-daily formulation) and tacrolimus laboratory analysis were included in the study. Times of tacrolimus administration and laboratory study collection were extracted and time distribution plots for each step in the inpatient TDM process were generated. Trough levels were drawn appropriately in 25.9% of the cases. Timing between doses was consistent, with 91.9% of the following dose administrations occurring 12 +/- 2 hours after the previous dose. Only 38.1% of the drug administrations occurred within one hour of laboratory study collection. Tacrolimus-related patient safety events were reported at a rate of 1.9 events per month while incorrect timing of TDM sample collection occurred approximately 200 times per month. Root cause analysis identified a TDM process marked by a lack of communication and coordination of drug administration and TDM sample collection. Extrapolating findings nationwide, we estimate $22 million in laboratory costs wasted annually. Based on this large single-center study, the authors concluded that the inpatient TDM process is prone to timing errors, thus is financially wasteful, and at its worst harmful to patients due to clinical decisions being made on the basis of unreliable data. Further work is needed on systems solutions to better align the laboratory study collection and drug administration processes.

  8. Sensor-triggered sampling to determine instantaneous airborne vapor exposure concentrations.

    PubMed

    Smith, Philip A; Simmons, Michael K; Toone, Phillip

    2018-06-01

    It is difficult to measure transient airborne exposure peaks by means of integrated sampling for organic chemical vapors, even with very short-duration sampling. Selection of an appropriate time to measure an exposure peak through integrated sampling is problematic, and short-duration time-weighted average (TWA) values obtained with integrated sampling are not likely to accurately determine actual peak concentrations attained when concentrations fluctuate rapidly. Laboratory analysis for integrated exposure samples is preferred from a certainty standpoint over results derived in the field from a sensor, as a sensor user typically must overcome specificity issues and a number of potential interfering factors to obtain similarly reliable data. However, sensors are currently needed to measure intra-exposure period concentration variations (i.e., exposure peaks). In this article, the digitized signal from a photoionization detector (PID) sensor triggered collection of whole-air samples when toluene or trichloroethylene vapors attained pre-determined levels in a laboratory atmosphere generation system. Analysis by gas chromatography-mass spectrometry of whole-air samples (with both 37 and 80% relative humidity) collected using the triggering mechanism with rapidly increasing vapor concentrations showed good agreement with the triggering set point values. Whole-air samples (80% relative humidity) in canisters demonstrated acceptable 17-day storage recoveries, and acceptable precision and bias were obtained. The ability to determine exceedance of a ceiling or peak exposure standard by laboratory analysis of an instantaneously collected sample, and to simultaneously provide a calibration point to verify the correct operation of a sensor was demonstrated. This latter detail may increase the confidence in reliability of sensor data obtained across an entire exposure period.

  9. Formaldehyde Exposures in a University Anatomy Laboratory

    NASA Astrophysics Data System (ADS)

    Winkler, Kyle William

    Air sampling studies were conducted within a university anatomical laboratory during the embalmment of a cadaver in order to determine if dangerous concentrations of formaldehyde existed. Three air sampling studies were conducted in the anatomical laboratory on three separate days that a cadaver was being embalmed. Samples were collected and analyzed using the Occupational Safety and Health Administration (OSHA) Sampling and Analytical Methods: Method 52. Each air sampling study sampled for short term exposure limit (STEL) and time weighted mean (TWA) breathing zone formaldehyde concentrations as well as area TWA formaldehyde concentrations. A personal aldehyde monitor was also used in each air sampling study to sample for breathing zone formaldehyde concentrations. Measured TWA mean exposures to formaldehyde ranged from 0.15--1.3 parts per million (ppm), STEL formaldehyde exposures ranged from 0.019--0.64 ppm, and eight-hour TWAs ranged from 0.03 to 3.6 ppm. All 8-hour TWA formaldehyde concentrations sampled in the anatomy laboratory during an embalmment were less than the permissible exposure limit (PEL) required by OSHA.

  10. 78 FR 37219 - Information Collection Request Submitted to OMB for Review and Approval; Comment Request; RadNet...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-20

    ... restricted by statute. FOR FURTHER INFORMATION CONTACT: Charles M. Petko, Office of Radiation and Indoor Air... national network of stations collecting sampling media that include air, precipitation, drinking water, and milk. Samples are sent to EPA's National Air and Radiation Environmental Laboratory (NAREL) in...

  11. Blood meal analysis of tabanid fly after it biting the rare Sumatran rhinoceros.

    PubMed

    Rovie-Ryan, Jeffrine Japning; Zainuddin, Zainal Zahari; Marni, Wahap; Ahmad, Abdul Hamid; Ambu, Laurentius N; Payne, Junaidi

    2013-02-01

    To demonstrate a noninvasive large mammalian genetic sampling method using blood meal obtained from a tabanid fly. Blood meal was recovered from the abdomen of an engorged tabanid fly (Haematopota sp.) which was captured immediately after biting a Sumatran rhino in captivity. The blood was applied on to a Whatman FTA(®) blood card. Subsequent laboratory work was conducted to extract, amplify and sequence the DNA from the sample. Validation was done by sampling the hair follicles and blood samples from the rhinoceros and subjecting it to the same laboratory process. BLAST search and constructed phylogenetic trees confirmed the blood meal samples were indeed from the rhino. This method could be used in the field application to noninvasively collect genetic samples. Collection of tabanids and other haematophagous arthropods (e.g. mosquitoes and ticks) and other blood-sucking parasites (e.g. leeches and worms) could also provide information on vector-borne diseases.

  12. Current laboratory requirements for adrenocorticotropic hormone and renin/aldosterone sample handling are unnecessarily restrictive.

    PubMed

    Chakera, Ali J; McDonald, Timothy J; Knight, Bridget A; Vaidya, Bijay; Jones, Angus G

    2017-02-01

    Samples for adrenocorticotropic hormone (ACTH) and aldosterone/renin analysis usually require rapid transport to the receiving laboratory for immediate separation and freezing. In practice, this means assessment is limited to hospital settings and many samples are rejected. We examined whether these requirements are necessary by assessing the stability of ACTH, aldosterone and renin over 48 hours in whole blood collected in serum gel and EDTA plasma from 31 participants. Our results show that ACTH collected into EDTA plasma is stable at room temperature for at least 6 hours, mean change at 6 hours -2.6% (95% CI -9.7 to 4.5). Both aldosterone and renin were stable collected on serum gel at room temperature for at least 6 hours: mean change aldosterone +0.2% (95% CI -3.6 to 4.0), renin -1.9% (95% CI -7.0 to3.2). Therefore, by using appropriate preservatives, ACTH and aldosterone/renin can be measured on samples collected at room temperature and processed within 6 hours. This would facilitate outpatient and emergency room assessment of these analytes. © Royal College of Physicians 2017. All rights reserved.

  13. Water Quality Index for measuring drinking water quality in rural Bangladesh: a cross-sectional study.

    PubMed

    Akter, Tahera; Jhohura, Fatema Tuz; Akter, Fahmida; Chowdhury, Tridib Roy; Mistry, Sabuj Kanti; Dey, Digbijoy; Barua, Milan Kanti; Islam, Md Akramul; Rahman, Mahfuzar

    2016-02-09

    Public health is at risk due to chemical contaminants in drinking water which may have immediate health consequences. Drinking water sources are susceptible to pollutants depending on geological conditions and agricultural, industrial, and other man-made activities. Ensuring the safety of drinking water is, therefore, a growing problem. To assess drinking water quality, we measured multiple chemical parameters in drinking water samples from across Bangladesh with the aim of improving public health interventions. In this cross-sectional study conducted in 24 randomly selected upazilas, arsenic was measured in drinking water in the field using an arsenic testing kit and a sub-sample was validated in the laboratory. Water samples were collected to test water pH in the laboratory as well as a sub-sample of collected drinking water was tested for water pH using a portable pH meter. For laboratory testing of other chemical parameters, iron, manganese, and salinity, drinking water samples were collected from 12 out of 24 upazilas. Drinking water at sample sites was slightly alkaline (pH 7.4 ± 0.4) but within acceptable limits. Manganese concentrations varied from 0.1 to 5.5 mg/L with a median value of 0.2 mg/L. The median iron concentrations in water exceeded WHO standards (0.3 mg/L) at most of the sample sites and exceeded Bangladesh standards (1.0 mg/L) at a few sample sites. Salinity was relatively higher in coastal districts. After laboratory confirmation, arsenic concentrations were found higher in Shibchar (Madaripur) and Alfadanga (Faridpur) compared to other sample sites exceeding WHO standard (0.01 mg/L). Of the total sampling sites, 33 % had good-quality water for drinking based on the Water Quality Index (WQI). However, the majority of the households (67 %) used poor-quality drinking water. Higher values of iron, manganese, and arsenic reduced drinking water quality. Awareness raising on chemical contents in drinking water at household level is required to improve public health.

  14. Methods for collection and analysis of water samples

    USGS Publications Warehouse

    Rainwater, Frank Hays; Thatcher, Leland Lincoln

    1960-01-01

    This manual contains methods used by the U.S. Geological Survey to collect, preserve, and analyze water samples. Throughout, the emphasis is on obtaining analytical results that accurately describe the chemical composition of the water in situ. Among the topics discussed are selection of sampling sites, frequency of sampling, field equipment, preservatives and fixatives, analytical techniques of water analysis, and instruments. Seventy-seven laboratory and field procedures are given for determining fifty-three water properties.

  15. Soil Gas Sampling

    EPA Pesticide Factsheets

    Field Branches Quality System and Technical Procedures: This document describes general and specific procedures, methods and considerations to be used and observed when collecting soil gas samples for field screening or laboratory analysis.

  16. Summary and Evaluation of the Quality of Stormwater in Denver, Colorado, October 2001 to October 2005

    USGS Publications Warehouse

    Bossong, Clifford R.; Fleming, Andrea C.

    2008-01-01

    Stormwater in the Denver area was sampled by the U.S. Geological Survey, in cooperation with the Urban Drainage and Flood Control District, in a network of five monitoring stations - three on the South Platte River and two on tributary streams, beginning in October 2001 and continuing through October 11, 2005. Composite samples of stormwater were analyzed at the U.S. Geological Survey National Water Quality Laboratory during water years 2003-2005 and the Metro Wastewater Reclamation District Laboratory during water year 2002 for water-quality properties such as pH, specific conductance, hardness, and residue on evaporation at 105 degrees Celsius; and for constituents such as major ions (calcium, chloride, fluoride, magnesium, potassium, sodium, and sulfate) in 2005, organic carbon and nutrients, including ammonia, nitrite plus nitrate, ammonia plus organic nitrogen, phosphorus, and orthophosphate; and for metals, including total and dissolved phases of copper, lead, manganese, and zinc. Samples analyzed for bacteriological indicators such as Escherichia coli and fecal coliform collected during selected storms also were analyzed at the Metro Wastewater Reclamation Laboratory. Discrete samples collected during selected storms were analyzed at the U.S. Geological Survey National Water Quality Laboratory for a suite of water-quality properties and constituents similar to those analyzed in the composite samples but that did not include determinations for total phases of metals. Streamflow characteristics associated with 176 composite stormwater samples indicate that most samples were collected from hydrographs classified as falling or event hydrographs and that only a few samples were collected from rising hydrographs. Results from laboratory analyses of the composite samples indicate spatial patterns in which concentrations for some constituents increase with contributing drainage area in the South Platte River and Sand Creek, but no well-defined relation with the amount of urban land cover was identified using data available from the U.S. Geological Survey National Land Cover data. Results from 22 discrete samples collected during two storms and used to obtain composited results with various weighting methods indicate that correlation coefficients between time-weighted and volume-weighted concentrations were generally at least 0.65, indicating a strong direct correlation between the two weighting methods for the stations involved in this study. In addition, the central tendency for relative percent differences between the time- and volume-weighting methods typically has an absolute value of about 10 or less, indicating good agreement for these weighting methods for data collected as part of this study. Comparison of stormwater results to numeric standards for streams developed by the Colorado Department of Public Health and Environment on the basis of use classifications indicates that, for water-quality properties and constituents other than bacteriological indicators, there were very few exceptions to numeric standards. Bacteriological indicators, however, such as Escherichia coli and fecal coliform consistently exceeded numeric standards in all bacteriological samples. An evaluation of laboratory results from composite samples on the basis of annual means indicates the presence of some simple upward and downward temporal trends in concentrations. In general, for annual means of results for all stations, hardness, ammonia plus organic nitrogen, total phosphorus, most dissolved metals (lead, manganese, and zinc), and all total metals (copper, lead, manganese, and zinc) all indicate annual means that decrease each year, or downward trends. Some trends were indicated only at individual stations in the network rather than at all stations. Ammonia as nitrogen at Union, Denver, and Henderson, orthophosphate at Sand Creek, and nitrite plus nitrate at Denver and Henderson all indicate decreasing annual means, or downward tr

  17. Radionuclides, inorganic constitutents, organic compounds, and bacteria in water from selected wells and springs from the southern boundary of the Idaho National Engineering Laboratory to the Hagerman Area, Idaho, 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartholomay, R.C.; Edwards, D.D.; Campbell, L.J.

    1994-11-01

    The U.S. Geological Survey and the Idaho Department of Water Resources, in response to a request from the U.S. Department of Energy, sampled 18 sites as part of a long-term project to monitor water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering Laboratory to the Hagerman area. Water samples were collected and analyzed for selected radionuclides, inorganic constituents, organic compounds, and bacteria. The samples were collected from 13 irrigation wells, 1 domestic well, 1 spring, 2 stock wells, and 1 public supply well. Quality assurance samples also were collected and analyzed. Nonemore » of the samples analyzed for radionuclides, inorganic constituents, or organic compounds exceeded the established maximum contaminant levels for drinking water. Most of the radionuclide and inorganic constituent concentrations exceeded their respective reporting levels. Most of the samples analyzed for surfactants and dissolved organic carbon had concentrations that exceeded their reporting levels. None of the samples contained reportable concentrations of purgeable organic compounds or pesticides. Total coliform bacteria was present in nine samples.« less

  18. BOREAS TE-2 NSA Soil Lab Data

    NASA Technical Reports Server (NTRS)

    Veldhuis, Hugo; Hall, Forrest G. (Editor); Knapp, David E. (Editor)

    2000-01-01

    This data set contains the major soil properties of soil samples collected in 1994 at the tower flux sites in the Northern Study Area (NSA). The soil samples were collected by Hugo Veldhuis and his staff from the University of Manitoba. The mineral soil samples were largely analyzed by Barry Goetz, under the supervision of Dr. Harold Rostad at the University of Saskatchewan. The organic soil samples were largely analyzed by Peter Haluschak, under the supervision of Hugo Veldhuis at the Centre for Land and Biological Resources Research in Winnipeg, Manitoba. During the course of field investigation and mapping, selected surface and subsurface soil samples were collected for laboratory analysis. These samples were used as benchmark references for specific soil attributes in general soil characterization. Detailed soil sampling, description, and laboratory analysis were performed on selected modal soils to provide examples of common soil physical and chemical characteristics in the study area. The soil properties that were determined include soil horizon; dry soil color; pH; bulk density; total, organic, and inorganic carbon; electric conductivity; cation exchange capacity; exchangeable sodium, potassium, calcium, magnesium, and hydrogen; water content at 0.01, 0.033, and 1.5 MPascals; nitrogen; phosphorus: particle size distribution; texture; pH of the mineral soil and of the organic soil; extractable acid; and sulfur. These data are stored in ASCII text files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).

  19. A Coastal Environment Field and Laboratory Activity for an Undergraduate Geomorphology Course

    ERIC Educational Resources Information Center

    Ellis, Jean T.; Rindfleisch, Paul R.

    2006-01-01

    A field and laboratory exercise for an undergraduate geomorphology class is described that focuses on the beach. The project requires one day of fieldwork and two laboratory sessions. In the field, students measure water surface fluctuations (waves) with a pressure sensor, survey beach profiles, collect sediment samples, and observe the beach…

  20. Validation of DESS as a DNA Preservation Method for the Detection of Strongyloides spp. in Canine Feces.

    PubMed

    Beknazarova, Meruyert; Millsteed, Shelby; Robertson, Gemma; Whiley, Harriet; Ross, Kirstin

    2017-06-09

    Strongyloides stercoralis is a gastrointestinal parasitic nematode with a life cycle that includes free-living and parasitic forms. For both clinical (diagnostic) and environmental evaluation, it is important that we can detect Strongyloides spp. in both human and non-human fecal samples. Real-time PCR is the most feasible method for detecting the parasite in both clinical and environmental samples that have been preserved. However, one of the biggest challenges with PCR detection is DNA degradation during the postage time from rural and remote areas to the laboratory. This study included a laboratory assessment and field validation of DESS (dimethyl sulfoxide, disodium EDTA, and saturated NaCl) preservation of Strongyloides spp. DNA in fecal samples. The laboratory study investigated the capacity of 1:1 and 1:3 sample to DESS ratios to preserve Strongyloides ratti in spike canine feces. It was found that both ratios of DESS significantly prevented DNA degradation compared to the untreated sample. This method was then validated by applying it to the field-collected canine feces and detecting Strongyloides DNA using PCR. A total of 37 canine feces samples were collected and preserved in the 1:3 ratio (sample: DESS) and of these, 17 were positive for Strongyloides spp. The study shows that both 1:1 and 1:3 sample to DESS ratios were able to preserve the Strongyloides spp. DNA in canine feces samples stored at room temperature for up to 56 days. This DESS preservation method presents the most applicable and feasible method for the Strongyloides DNA preservation in field-collected feces.

  1. Could light meal jeopardize laboratory coagulation tests?

    PubMed

    Lima-Oliveira, Gabriel; Salvagno, Gian Luca; Lippi, Giuseppe; Danese, Elisa; Gelati, Matteo; Montagnana, Martina; Picheth, Geraldo; Guidi, Gian Cesare

    2014-01-01

    Presently the necessity of fasting time for coagulation tests is not standardized. Our hypothesis is that this can harm patient safety. This study is aimed at evaluating whether a light meal (i.e. breakfast) can jeopardize laboratory coagulation tests. A blood sample was firstly collected from 17 fasting volunteers (12 h). Immediately after blood collection, the volunteers consumed a light meal. Then samples were collected at 1, 2 and 4 h after the meal. Coagulation tests included: activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen (Fbg), antithrombin III (AT), protein C (PC) and protein S (PS). Differences between samples were assessed by Wilcoxon ranked-pairs test. The level of statistical significance was set at P < 0.05. Mean % differences were determined and differences between and baseline and 1, 2 and 4h samples were compared with reference change value (RCV). A significantly higher % activity of AT was observed at 1 h and 4 h after meal vs. baseline specimen [113 (104-117) and 111 (107-120) vs. 109 (102-118), respectively; P = 0.029 and P = 0.016]. APTT at 2 h was found significantly lower than baseline samples [32.0 (29.9-34.8) vs. 34.1 (32.2-35.2), respectively; P = 0.041]. The results of both Fbg and PS tests were not influenced by a light meal. Furthermore, no coagulation tests had significant variation after comparison with RCV. A light meal does not influence the laboratory coagulation tests we assessed, but we suggest that the laboratory quality managers standardize the fasting time for all blood tests at 12 hours, to completely metabolize the lipids intake.

  2. Skylab mobile laboratory

    NASA Technical Reports Server (NTRS)

    Primeaux, G. R.; Larue, M. A.

    1975-01-01

    The Skylab mobile laboratory was designed to provide the capability to obtain necessary data on the Skylab crewmen 30 days before lift-off, within 1 hour after recovery, and until preflight physiological baselines were reattained. The mobile laboratory complex consisted of six laboratories that supported cardiovascular, metabolic, nutrition and endocrinology, operational medicine, blood, and microbiology experiments; a utility package; and two shipping containers. The objectives and equipment requirements of the Skylab mobile laboratory and the data acquisition systems are discussed along with processes such as permanently mounting equipment in the individual laboratories and methods of testing and transporting the units. The operational performance, in terms of amounts of data collected, and the concept of mobile laboratories for medical and scientific experiments are evaluated. The Skylab mobile laboratory succeeded in facilitating the data collection and sample preservation associated with the three Skylab manned flights.

  3. Analysis of Samples Collected from the Surface of Interim Storage Canisters at Calvert Cliffs in June 2017: Revision 01.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bryan, Charles R.; Schindelholz, Eric John

    In June 2017, dust and salt samples were collected from the surface of Spent Nuclear Fuel (SNF) dry storage canisters at the Calvert Cliffs Nuclear Power Plant. The samples were delivered to Sandia National laboratories for analysis. Two types of samples were collected: filter-backed Scotch-Brite TM pads were used to collect dry dust samples for characterization of salt and dust morphologies and distributions; and Saltsmart TM test strips were used to collect soluble salts for determining salt surface loadings per unit area. After collection, the samples were sealed into plastic sleeves for shipping. Condensation within the sleeves containing the Scotch-Britemore » TM samples remobilized the salts, rendering them ineffective for the intended purpose, and also led to mold growth, further compromising the samples; for these reasons, the samples were not analyzed. The SaltSmart TM samples were unaffected and were analyzed by ion chromatography for major anions and cations. The results of those analyses are presented here.« less

  4. Tank Vapor Sampling and Analysis Data Package for Tank 241-Z-361 Sampled 09/22/1999 and 09/271999 During Sludge Core Removal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    VISWANATH, R.S.

    This data package presents sampling data and analytical results from the September 22 and 27, 1999, headspace vapor sampling of Hanford Site Tank 241-2-361 during sludge core removal. The Lockheed Martin Hanford Corporation (LMHC) sampling team collected the samples and Waste Management Laboratory (WML) analyzed the samples in accordance with the requirements specified in the 241-2361 Sludge Characterization Sampling and Analysis Plan, (SAP), HNF-4371, Rev. 1, (Babcock and Wilcox Hanford Corporation, 1999). Six SUMMA{trademark} canister samples were collected on each day (1 ambient field blank and 5 tank vapor samples collected when each core segment was removed). The samples weremore » radiologically released on September 28 and October 4, 1999, and received at the laboratory on September 29 and October 6, 1999. Target analytes were not detected at concentrations greater than their notification limits as specified in the SAP. Analytical results for the target analytes and tentatively identified compounds (TICs) are presented in Section 2.2.2 starting on page 2B-7. Three compounds identified for analysis in the SAP were analyzed as TICs. The discussion of this modification is presented in Section 2.2.1.2.« less

  5. Improving laboratory results turnaround time by reducing pre analytical phase.

    PubMed

    Khalifa, Mohamed; Khalid, Parwaiz

    2014-01-01

    Laboratory turnaround time is considered one of the most important indicators of work efficiency in hospitals, physicians always need timely results to take effective clinical decisions especially in the emergency department where these results can guide physicians whether to admit patients to the hospital, discharge them home or do further investigations. A retrospective data analysis study was performed to identify the effects of ER and Lab staff training on new routines for sample collection and transportation on the pre-analytical phase of turnaround time. Renal profile tests requested by the ER and performed in 2013 has been selected as a sample, and data about 7,519 tests were retrieved and analyzed to compare turnaround time intervals before and after implementing new routines. Results showed significant time reduction on "Request to Sample Collection" and "Collection to In Lab Delivery" time intervals with less significant improvement on the analytical phase of the turnaround time.

  6. Radiochemical and Chemical Constituents in Water from Selected Wells and Springs from the Southern Boundary of the Idaho National Engineering and Environmental Laboratory to the Hagerman Area, Idaho, 1997

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. C. Bartholomay; L. M. Williams; L. J. Campbell

    1998-12-01

    The U.S. Geological Survey and the Idaho Department of Water Resources, in cooperation with the U.S. Department of Energy, sampled 18 sites as part of the fourth round of a long-term project to monitor water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering and Environmental Laboratory to the Hagerman area. Water samples were collected and analyzed for selected radiochemical and chemical constituents. The samples were collected from seven domestic wells, six irrigation wells, two springs, one dairy well, one observation well, and one stock well. Two quality-assurance samples also were collected andmore » analyzed. None of the radiochemical or chemical constituents exceeded the established maximum contaminant levels for drinking water. Many of the radionuclide- and inorganic-constituent concentrations were greater than their respective reporting levels.« less

  7. Analysis of on-line clinical laboratory manuals and practical recommendations.

    PubMed

    Beckwith, Bruce; Schwartz, Robert; Pantanowitz, Liron

    2004-04-01

    On-line clinical laboratory manuals are a valuable resource for medical professionals. To our knowledge, no recommendations currently exist for their content or design. To analyze publicly accessible on-line clinical laboratory manuals and to propose guidelines for their content. We conducted an Internet search for clinical laboratory manuals written in English with individual test listings. Four individual test listings in each manual were evaluated for 16 data elements, including sample requirements, test methodology, units of measure, reference range, and critical values. Web sites were also evaluated for supplementary information and search functions. We identified 48 on-line laboratory manuals, including 24 academic or community hospital laboratories and 24 commercial or reference laboratories. All manuals had search engines and/or test indices. No single manual contained all 16 data elements evaluated. An average of 8.9 (56%) elements were present (range, 4-14). Basic sample requirements (specimen and volume needed) were the elements most commonly present (98% of manuals). The frequency of the remaining data elements varied from 10% to 90%. On-line clinical laboratory manuals originate from both hospital and commercial laboratories. While most manuals were user-friendly and contained adequate specimen-collection information, other important elements, such as reference ranges, were frequently absent. To ensure that clinical laboratory manuals are of maximal utility, we propose the following 13 data elements be included in individual test listings: test name, synonyms, test description, test methodology, sample requirements, volume requirements, collection guidelines, transport guidelines, units of measure, reference range, critical values, test availability, and date of latest revision.

  8. 40 CFR 141.35 - Reporting for unregulated contaminant monitoring results.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... up to 30 characters assigned by the laboratory to uniquely identify containers, or groups of containers, containing water samples collected at the same sampling location for the same sampling date. 9... each sample event. This will associate samples with the PWS monitoring plan to allow EPA to track...

  9. 40 CFR 141.35 - Reporting for unregulated contaminant monitoring results.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... up to 30 characters assigned by the laboratory to uniquely identify containers, or groups of containers, containing water samples collected at the same sampling location for the same sampling date. 9... each sample event. This will associate samples with the PWS monitoring plan to allow EPA to track...

  10. 40 CFR 141.35 - Reporting for unregulated contaminant monitoring results.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... up to 30 characters assigned by the laboratory to uniquely identify containers, or groups of containers, containing water samples collected at the same sampling location for the same sampling date. 9... each sample event. This will associate samples with the PWS monitoring plan to allow EPA to track...

  11. Water-quality data at amphibian research sites in Maryland, Washington, D.C., and Virginia, 2005-2007

    USGS Publications Warehouse

    Rice, Karen C.

    2008-01-01

    Data on the chemical composition of water were collected at least once from 47 amphibian research sites in Maryland, Washington, D.C., and Virginia, from 2005 through 2007. One hundred twenty-five water samples were collected from vernal pools and streams and analyzed as part of long-term monitoring projects of the U.S. Geological Survey Amphibian Research and Monitoring Initiative in the Northeast Region. Field measurements of water temperature, specific conductance, and pH were made. Laboratory analyses of the water samples included acid-neutralizing capacity, total Kjeldahl nitrogen (ammonium plus organic nitrogen), nitrite plus nitrate, total nitrogen, and total phosphorus concentrations. Field and laboratory analytical results of water samples and quality-assurance data are presented.

  12. Dissolved Pesticide and Organic Carbon Concentrations Detected in Surface Waters, Northern Central Valley, California, 2001-2002

    USGS Publications Warehouse

    Orlando, James L.; Jacobson, Lisa A.; Kuivila, Kathryn

    2004-01-01

    Field and laboratory studies were conducted to determine the effects of pesticide mixtures on Chinook salmon under various environmental conditions in surface waters of the northern Central Valley of California. This project was a collaborative effort between the U.S. Geological Survey (USGS) and the University of California. The project focused on understanding the environmental factors that influence the toxicity of pesticides to juvenile salmon and their prey. During the periods January through March 2001 and January through May 2002, water samples were collected at eight surface water sites in the northern Central Valley of California and analyzed by the USGS for dissolved pesticide and dissolved organic carbon concentrations. Water samples were also collected by the USGS at the same sites for aquatic toxicity testing by the Aquatic Toxicity Laboratory at the University of California Davis; however, presentation of the results of these toxicity tests is beyond the scope of this report. Samples were collected to characterize dissolved pesticide and dissolved organic carbon concentrations, and aquatic toxicity, associated with winter storm runoff concurrent with winter run Chinook salmon out-migration. Sites were selected that represented the primary habitat of juvenile Chinook salmon and included major tributaries within the Sacramento and San Joaquin River Basins and the Sacramento?San Joaquin Delta. Water samples were collected daily for a period of seven days during two winter storm events in each year. Additional samples were collected weekly during January through April or May in both years. Concentrations of 31 currently used pesticides were measured in filtered water samples using solid-phase extraction and gas chromatography-mass spectrometry at the U.S. Geological Survey's organic chemistry laboratory in Sacramento, California. Dissolved organic carbon concentrations were analyzed in filtered water samples using a Shimadzu TOC-5000A total organic carbon analyzer.

  13. Examining Infants' Cortisol Responses to Laboratory Tasks among Children Varying in Attachment Disorganization: Stress Reactivity or Return to Baseline?

    ERIC Educational Resources Information Center

    Bernard, Kristin; Dozier, Mary

    2010-01-01

    Cortisol is a hormone involved in mounting a stress response in humans. The evidence of stress reactivity among young children has been mixed, however. In the present study, the order of two laboratory tasks (i.e., Strange Situation and play) was counterbalanced, and home saliva samples were obtained. Saliva samples were also collected upon the…

  14. Blood gas testing and related measurements: National recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Dukić, Lora; Kopčinović, Lara Milevoj; Dorotić, Adrijana; Baršić, Ivana

    2016-10-15

    Blood gas analysis (BGA) is exposed to risks of errors caused by improper sampling, transport and storage conditions. The Clinical and Laboratory Standards Institute (CLSI) generated documents with recommendations for avoidance of potential errors caused by sample mishandling. Two main documents related to BGA issued by the CLSI are GP43-A4 (former H11-A4) Procedures for the collection of arterial blood specimens; approved standard - fourth edition, and C46-A2 Blood gas and pH analysis and related measurements; approved guideline - second edition. Practices related to processing of blood gas samples are not standardized in the Republic of Croatia. Each institution has its own protocol for ordering, collection and analysis of blood gases. Although many laboratories use state of the art analyzers, still many preanalytical procedures remain unchanged. The objective of the Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM) is to standardize the procedures for BGA based on CLSI recommendations. The Working Group for Blood Gas Testing as part of the Committee for the Scientific Professional Development of the CSMBLM prepared a set of recommended protocols for sampling, transport, storage and processing of blood gas samples based on relevant CLSI documents, relevant literature search and on the results of Croatian survey study on practices and policies in acid-base testing. Recommendations are intended for laboratory professionals and all healthcare workers involved in blood gas processing.

  15. Blood gas testing and related measurements: National recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine

    PubMed Central

    Dukić, Lora; Kopčinović, Lara Milevoj; Dorotić, Adrijana; Baršić, Ivana

    2016-01-01

    Blood gas analysis (BGA) is exposed to risks of errors caused by improper sampling, transport and storage conditions. The Clinical and Laboratory Standards Institute (CLSI) generated documents with recommendations for avoidance of potential errors caused by sample mishandling. Two main documents related to BGA issued by the CLSI are GP43-A4 (former H11-A4) Procedures for the collection of arterial blood specimens; approved standard – fourth edition, and C46-A2 Blood gas and pH analysis and related measurements; approved guideline – second edition. Practices related to processing of blood gas samples are not standardized in the Republic of Croatia. Each institution has its own protocol for ordering, collection and analysis of blood gases. Although many laboratories use state of the art analyzers, still many preanalytical procedures remain unchanged. The objective of the Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM) is to standardize the procedures for BGA based on CLSI recommendations. The Working Group for Blood Gas Testing as part of the Committee for the Scientific Professional Development of the CSMBLM prepared a set of recommended protocols for sampling, transport, storage and processing of blood gas samples based on relevant CLSI documents, relevant literature search and on the results of Croatian survey study on practices and policies in acid-base testing. Recommendations are intended for laboratory professionals and all healthcare workers involved in blood gas processing. PMID:27812301

  16. The precision of wet atmospheric deposition data from national atmospheric deposition program/national trends network sites determined with collocated samplers

    USGS Publications Warehouse

    Nilles, M.A.; Gordon, J.D.; Schroder, L.J.

    1994-01-01

    A collocated, wet-deposition sampler program has been operated since October 1988 by the U.S. Geological Survey to estimate the overall sampling precision of wet atmospheric deposition data collected at selected sites in the National Atmospheric Deposition Program and National Trends Network (NADP/NTN). A duplicate set of wet-deposition sampling instruments was installed adjacent to existing sampling instruments at four different NADP/NTN sites for each year of the study. Wet-deposition samples from collocated sites were collected and analysed using standard NADP/NTN procedures. Laboratory analyses included determinations of pH, specific conductance, and concentrations of major cations and anions. The estimates of precision included all variability in the data-collection system, from the point of sample collection through storage in the NADP/NTN database. Sampling precision was determined from the absolute value of differences in the analytical results for the paired samples in terms of median relative and absolute difference. The median relative difference for Mg2+, Na+, K+ and NH4+ concentration and deposition was quite variable between sites and exceeded 10% at most sites. Relative error for analytes whose concentrations typically approached laboratory method detection limits were greater than for analytes that did not typically approach detection limits. The median relative difference for SO42- and NO3- concentration, specific conductance, and sample volume at all sites was less than 7%. Precision for H+ concentration and deposition ranged from less than 10% at sites with typically high levels of H+ concentration to greater than 30% at sites with low H+ concentration. Median difference for analyte concentration and deposition was typically 1.5-2-times greater for samples collected during the winter than during other seasons at two northern sites. Likewise, the median relative difference in sample volume for winter samples was more than double the annual median relative difference at the two northern sites. Bias accounted for less than 25% of the collocated variability in analyte concentration and deposition from weekly collocated precipitation samples at most sites.A collocated, wet-deposition sampler program has been operated since OCtober 1988 by the U.S Geological Survey to estimate the overall sampling precision of wet atmospheric deposition data collected at selected sites in the National Atmospheric Deposition Program and National Trends Network (NADP/NTN). A duplicate set of wet-deposition sampling instruments was installed adjacent to existing sampling instruments four different NADP/NTN sites for each year of the study. Wet-deposition samples from collocated sites were collected and analysed using standard NADP/NTN procedures. Laboratory analyses included determinations of pH, specific conductance, and concentrations of major cations and anions. The estimates of precision included all variability in the data-collection system, from the point of sample collection through storage in the NADP/NTN database.

  17. USE OF NATURAL WATERS AS U. S. GEOLOGICAL SURVEY REFERENCE SAMPLES.

    USGS Publications Warehouse

    Janzer, Victor J.

    1985-01-01

    The U. S. Geological Survey conducts research and collects hydrologic data relating to the Nation's water resources. Seven types of natural matrix reference water samples are prepared for use in the Survey's quality assurance program. These include samples containing major constituents, trace metals, nutrients, herbicides, insecticides, trace metals in a water and suspended-sediment mixture, and precipitation (snowmelt). To prepare these reference samples, natural water is collected in plastic drums and the sediment is allowed to settle. The water is then filtered, selected constituents are added, and if necessary the water is acidified and sterilized by ultraviolet irradiation before bottling in plastic or glass. These reference samples are distributed twice yearly to more than 100 laboratories for chemical analysis. The most probable values for each constituent are determined by evaluating the data submitted by the laboratories using statistical techniques recommended by ASTM.

  18. Vascular Blood Collection stowage in MELFI

    NASA Image and Video Library

    2010-08-26

    ISS024-E-012555 (26 Aug. 2010) --- NASA astronaut Tracy Caldwell Dyson, Expedition 24 flight engineer, replaces a dewar tray containing biological samples in the Minus Eighty Laboratory Freezer for ISS (MELFI-1) in the Kibo laboratory of the International Space Station.

  19. Vascular Blood Collection stowage in MELFI

    NASA Image and Video Library

    2010-08-26

    ISS024-E-012553 (26 Aug. 2010) --- NASA astronaut Tracy Caldwell Dyson, Expedition 24 flight engineer, replaces a dewar tray containing biological samples in the Minus Eighty Laboratory Freezer for ISS (MELFI-1) in the Kibo laboratory of the International Space Station.

  20. Screening for Saponins Using the Blood Hemolysis Test. An Undergraduate Laboratory Experiment.

    ERIC Educational Resources Information Center

    Sotheeswaran, Subramaniam

    1988-01-01

    Describes an experiment for undergraduate chemistry laboratories involving a chemical found in plants and some sea animals. Discusses collection and identification of material, a hemolysis test, preparation of blood-coated agar plates, and application of samples. (CW)

  1. Radionuclides, stable isotopes, inorganic constituents, and organic compounds in water from selected wells and springs from the southern boundary of the Idaho National Engineering Laboratory to the Hagerman Area, Idaho, 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartholomay, R.C.; Williams, L.M.; Campbell, L.J.

    1995-10-01

    The US Geological Survey and the Idaho Department of Water Resources, in response to a request from the US Department of Energy, samples 18 sites as part of a long-term project to monitor water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering Laboratory to the Hagerman area. Water samples were collected and analyzed for selected radionuclides, stable isotopes, inorganic constituents, and organic compounds. The samples were collected from seven irrigation wells, seven domestic wells, two springs, one stock well, and one observation well. Two quality assurance samples also were collected and analyzed.more » None of the radionuclide, inorganic constituent, or organic compound concentrations exceeded the established maximum contaminant levels for drinking water. Many of the radionuclide and inorganic constituent concentrations exceeded their respective reporting levels. All samples analyzed for dissolved organic carbon had concentrations that exceeded their minimum reporting levels.« less

  2. Radionuclides, stable isotopes, inorganic constituents, and organic compounds in water from selected wells and springs from the southern boundary of the Idaho National Engineering Laboratory to the Hagerman Area, Idaho, 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartholomay, R.C.; Williams, L.M.; Campbell, L.J.

    1996-09-01

    The US Geological Survey and the Idaho Department of Water Resources, in cooperation with the US Department of Energy, sampled 17 sites as part of a long-term project to monitor water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering Laboratory to the Hagerman area. Water samples were collected and analyzed for selected radionuclides, stable isotopes, inorganic constituents, and organic compounds. The samples were collected from 11 irrigation wells, 2 domestic wells, 2 stock wells, 1 spring, and 1 public-supply well. Two quality assurance samples also were collected and analyzed. None of themore » radionuclide, inorganic constituents, or organic compound concentrations exceeded the established maximum contaminant levels for drinking water. Many of the radionuclide and inorganic constituent concentrations were greater than their respective reporting levels. All samples analyzed for dissolved organic carbon had concentrations that were greater than the minimum reporting level.« less

  3. After site selection and before data analysis: sampling, sorting, and laboratory procedures used in stream benthic macroinvertebrate monitoring programs by USA state agencies

    USGS Publications Warehouse

    Carter, James L.; Resh, Vincent H.

    2001-01-01

    A survey of methods used by US state agencies for collecting and processing benthic macroinvertebrate samples from streams was conducted by questionnaire; 90 responses were received and used to describe trends in methods. The responses represented an estimated 13,000-15,000 samples collected and processed per year. Kicknet devices were used in 64.5% of the methods; other sampling devices included fixed-area samplers (Surber and Hess), artificial substrates (Hester-Dendy and rock baskets), grabs, and dipnets. Regional differences existed, e.g., the 1-m kicknet was used more often in the eastern US than in the western US. Mesh sizes varied among programs but 80.2% of the methods used a mesh size between 500 and 600 (mu or u)m. Mesh size variations within US Environmental Protection Agency regions were large, with size differences ranging from 100 to 700 (mu or u)m. Most samples collected were composites; the mean area sampled was 1.7 m2. Samples rarely were collected using a random method (4.7%); most samples (70.6%) were collected using "expert opinion", which may make data obtained operator-specific. Only 26.3% of the methods sorted all the organisms from a sample; the remainder subsampled in the laboratory. The most common method of subsampling was to remove 100 organisms (range = 100-550). The magnification used for sorting ranged from 1 (sorting by eye) to 30x, which results in inconsistent separation of macroinvertebrates from detritus. In addition to subsampling, 53% of the methods sorted large/rare organisms from a sample. The taxonomic level used for identifying organisms varied among taxa; Ephemeroptera, Plecoptera, and Trichoptera were generally identified to a finer taxonomic resolution (genus and species) than other taxa. Because there currently exists a large range of field and laboratory methods used by state programs, calibration among all programs to increase data comparability would be exceptionally challenging. However, because many techniques are shared among methods, limited testing could be designed to evaluate whether procedural differences affect the ability to determine levels of environmental impairment using benthic macroinvertebrate communities.

  4. ENVIRONMENTAL RADIOACTIVITY AT ARGONNE NATIONAL LABORATORY. Report for the Year 1958

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sedlet, J.

    1959-08-01

    Data are tabulated on the radioactive content of samples of surface water, lake and stream bottom silt, soil, plants, and air filters from the environs of the Argonne National Laboratory. Results are compared with those for similar samples collected from the area from 1952 through 1958. Fission prcduct activity from nuclear detocations was found in most samples from all locations. Fall-out activity was greatest during the spring and fall, and was particularly noticeable in air, precipitation, and plant samples. (For preceding period see ANL-5934.) (C.H.)

  5. National Water Quality Laboratory Profile

    USGS Publications Warehouse

    Raese, Jon W.

    1994-01-01

    The National Water Quality Laboratory determines organic and inorganic constituents in samples of surface and ground water, river and lake sediment, aquatic plant and animal material, and precipitation collected throughout the United States and its territories by the U.S. Geological Survey. In water year 1994, the Laboratory produced more than 900,000 analytical results for about 65,000 samples. The Laboratory also coordinates an extensive network of contract laboratories for the determination of radiochemical and stable isotopes and work for the U.S. Department of Defense Environmental Contamination Hydrology Program. Heightened concerns about water quality and about the possible effects of toxic chemicals at trace and ultratrace levels have contributed to an increased demand for impartial, objective, and independent data.

  6. Evaluation of OMNIgene®•SPUTUM-stabilised sputum for long-term transport and Xpert® MTB/RIF testing in Nepal.

    PubMed

    Maharjan, B; Kelly-Cirino, C D; Weirich, A; Curry, P S; Hoffman, H; Avsar, K; Shrestha, B

    2016-12-01

    German Nepal TB Project, National Tuberculosis Reference Laboratory, Kathmandu, Nepal. To evaluate whether transporting samples in OMNIgene®•SPUTUM (OM-S) reagent from a peripheral collection site to a central laboratory in Nepal can improve tuberculosis (TB) detection and increase the sensitivity of Xpert® MTB/RIF testing. One hundred sputum samples were split manually. Each portion was assigned to the OM-S group (OM-S added at collection, airline-couriered without cold chain, no other processing required) or the standard-of-care (SOC) group (samples airline-couriered on ice, sodium hydroxide + N-acetyl-L-cysteine processing required at the laboratory). Smear microscopy and Xpert testing were performed. Transport time was 2-13 days. Overall smear results were comparable (respectively 58% and 56% smear-negative results in the OM-S and SOC groups). The rate of smear-positive, Mycobacterium tuberculosis-positive (MTB+) sample detection was identical for both treatment groups, at 95%. More smear-negative MTB+ samples were detected in the OM-S group (17% vs. 13%, P = 0.0655). Sputum samples treated with OM-S can undergo multiday ambient-temperature transport and yield comparable smear and Xpert results to those of SOC samples. Further investigation with larger sample sizes is required to assess whether treating sputum samples with OM-S could increase the sensitivity of Xpert testing in smear-negative samples.

  7. Desert soil collection at the JPL soil science laboratory

    NASA Technical Reports Server (NTRS)

    Blank, G. B.; Cameron, R. E.

    1969-01-01

    Collection contains desert soils and other geologic materials collected from sites in the United States and foreign countries. Soils are useful for test purposes in research related to extraterrestrial life detection, sampling, harsh environmental studies, and determining suitable areas for training astronauts for lunar exploration.

  8. The Astromaterials X-Ray Computed Tomography Laboratory at Johnson Space Center

    NASA Technical Reports Server (NTRS)

    Zeigler, R. A.; Coleff, D. M.; McCubbin, F. M.

    2017-01-01

    The Astromaterials Acquisition and Curation Office at NASA's Johnson Space Center (hereafter JSC curation) is the past, present, and future home of all of NASA's astromaterials sample collections. JSC curation currently houses all or part of nine different sample collections: (1) Apollo samples (1969), (2) Lunar samples (1972), (3) Antarctic meteorites (1976), (4) Cosmic Dust particles (1981), (5) Microparticle Impact Collection (1985), (6) Genesis solar wind atoms (2004); (7) Stardust comet Wild-2 particles (2006), (8) Stardust interstellar particles (2006), and (9) Hayabusa asteroid Itokawa particles (2010). Each sample collection is housed in a dedicated clean room, or suite of clean rooms, that is tailored to the requirements of that sample collection. Our primary goals are to maintain the long-term integrity of the samples and ensure that the samples are distributed for scientific study in a fair, timely, and responsible manner, thus maximizing the return on each sample. Part of the curation process is planning for the future, and we also perform fundamental research in advanced curation initiatives. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of sample collections, or getting new results from existing sample collections [2]. We are (and have been) planning for future curation, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, and curation of organically- and biologically-sensitive samples. As part of these advanced curation efforts we are augmenting our analytical facilities as well. A micro X-Ray computed tomography (micro-XCT) laboratory dedicated to the study of astromaterials will be coming online this spring within the JSC Curation office, and we plan to add additional facilities that will enable nondestructive (or minimally-destructive) analyses of astromaterials in the near future (micro-XRF, confocal imaging Raman Spectroscopy). These facilities will be available to: (1) develop sample handling and storage techniques for future sample return missions; (2) be utilized by PET for future sample return missions; (3) be used for retroactive PET (Positron Emission Tomography)-style analyses of our existing collections; and (4) for periodic assessments of the existing sample collections. Here we describe the new micro-XCT system, as well as some of the ongoing or anticipated applications of the instrument.

  9. Vascular Blood Collection stowage in MELFI

    NASA Image and Video Library

    2010-08-26

    ISS024-E-012546 (26 Aug. 2010) --- NASA astronaut Tracy Caldwell Dyson, Expedition 24 flight engineer, prepares to insert biological samples in a dewar tray in the Minus Eighty Laboratory Freezer for ISS (MELFI-1) in the Kibo laboratory of the International Space Station.

  10. Vascular Blood Collection stowage in MELFI

    NASA Image and Video Library

    2010-08-26

    ISS024-E-012548 (26 Aug. 2010) --- NASA astronaut Tracy Caldwell Dyson, Expedition 24 flight engineer, prepares to insert biological samples in a dewar tray in the Minus Eighty Laboratory Freezer for ISS (MELFI-1) in the Kibo laboratory of the International Space Station.

  11. The Importance of Meteorite Collections to Sample Return Missions: Past, Present, and Future Considerations

    NASA Technical Reports Server (NTRS)

    Welzenbach, L. C.; McCoy, T. J.; Glavin, D. P.; Dworkin, J. P.; Abell, P. A.

    2012-01-01

    While much of the scientific community s current attention is drawn to sample return missions, it is the existing meteorite and cosmic dust collections that both provide the paradigms to be tested by these missions and the context for interpreting the results. Recent sample returns from the Stardust and Hayabusa missions provided us with new materials and insights about our Solar System history and processes. As an example, Stardust sampled CAIs among the population of cometary grains, requiring extensive and unexpected radial mixing in the early solar nebula. This finding would not have been possible, however, without extensive studies of meteoritic CAIs that established their high-temperature, inner Solar System formation. Samples returned by Stardust also revealed the first evidence of a cometary amino acid, a discovery that would not have been possible with current in situ flight instrument technology. The Hayabusa mission provided the final evidence linking ordinary chondrites and S asteroids, a hypothesis that developed from centuries of collection and laboratory and ground-based telescopic studies. In addition to these scientific findings, studies of existing meteorite collections have defined and refined the analytical techniques essential to studying returned samples. As an example, the fortuitous fall of the Allende CV3 and Murchison CM2 chondrites within months before the return of Apollo samples allowed testing of new state-of-the-art analytical facilities. The results of those studies not only prepared us to better study lunar materials, but unanticipated discoveries changed many of our concepts about the earliest history and processes of the solar nebula. This synergy between existing collections and future space exploration is certainly not limited to sample return missions. Laboratory studies confirmed the existence of meteorites from Mars and raised the provocative possibility of preservation of ancient microbial life. The laboratory studies in turn led to a new wave of Mars exploration that ultimately could lead to sample return focused on evidence for past or present life. This partnership between collections and missions will be increasingly important in the coming decades as we discover new questions to be addressed and identify targets for for both robotic and human exploration . Nowhere is this more true than in the ultimate search for the abiotic and biotic processes that produced life. Existing collections also provide the essential materials for developing and testing new analytical schemes to detect the rare markers of life and distinguish them from abiotic processes. Large collections of meteorites and the new types being identified within these collections, which come to us at a fraction of the cost of a sample return mission, will continue to shape the objectives of future missions and provide new ways of interpreting returned samples.

  12. CTEPP NC DATA SUPPLEMENTAL INFORMATION ON FIELD AND LABORATORY SAMPLES

    EPA Science Inventory

    This data set contains supplemental data related to the final core analytical results table. This includes sample collection data for example sample weight, air volume, creatinine, specific gravity etc.

    The Children’s Total Exposure to Persistent Pesticides and Other Persistent...

  13. Area of Concern (AOC) 314 Verification Survey at Former McClellan AFB, Sacramento, CA

    DTIC Science & Technology

    2015-03-31

    also collected 22 soil samples from within AOC 314. Laboratory analysis revealed that the concentration of radium-226 (Ra-226) in 10 of the soil ...at least one sample that exceeded 2.0 pCi/g. The highest concentration of Ra-226 found in any of the soil samples was 25.8 pCi/g. Based on these...and ensure the potential health risk to future inhabitants is minimized. USAFSAM/OEC personnel also collected 22 soil samples from within AOC 314

  14. 50th Anniversary of the World's First Extraterrestrial Sample Receiving Laboratory: The Apollo Program's Lunar Receiving Laboratory

    NASA Technical Reports Server (NTRS)

    Calaway, M. J.; Allton, J. H.; Zeigler, R. A.; McCubbin, F. M.

    2017-01-01

    The Apollo program's Lunar Receiving Laboratory (LRL), building 37 at NASA's Manned Spaceflight Center (MSC), now Johnson Space Center (JSC), in Houston, TX, was the world's first astronaut and extraterrestrial sample quarantine facility (Fig. 1). It was constructed by Warrior Construction Co. and Warrior-Natkin-National at a cost of $8.1M be-tween August 10, 1966 and June 26, 1967. In 1969, the LRL received and curated the first collection of extra-terrestrial samples returned to Earth; the rock and soil samples of the Apollo 11 mission. This year, the JSC Astromaterials Acquisition and Curation Office (here-after JSC curation) celebrates 50 years since the opening of the LRL and its legacy of laying the foundation for modern curation of extraterrestrial samples.

  15. Laboratory evaluation of sample collection methods (organs vs swabs) for Tasmanian salmon reovirus detection in farmed Atlantic salmon, Salmo salar L.

    PubMed

    Zainathan, S C; Carson, J; Crane, M St J; Nowak, B F

    2013-04-01

    The use of swabs relative to organs as a sample collection method for the detection of Tasmanian salmon reovirus (TSRV) in farmed Tasmanian Atlantic salmon, Salmo salar L., was evaluated by RT-qPCR. Evaluation of individual and pooled sample collection (organs vs swabs) was carried out to determine the sensitivity of the collection methods and the effect of pooling of samples for the detection of TSRV. Detection of TSRV in individual samples was as sensitive when organs were sampled compared to swabs, and in pooled samples, organs demonstrated a sensitivity of one 10-fold dilution higher than sampling of pooled swabs. Storage of swabs at 4 °C for t = 24 h demonstrated results similar to those at t = 0. Advantages of using swabs as a preferred sample collection method for the detection of TSRV compared to organ samples are evident from these experimental trials. © 2012 Blackwell Publishing Ltd.

  16. Astromaterials Acquisition and Curation Office (KT) Overview

    NASA Technical Reports Server (NTRS)

    Allen, Carlton

    2014-01-01

    The Astromaterials Acquisition and Curation Office has the unique responsibility to curate NASA's extraterrestrial samples - from past and forthcoming missions - into the indefinite future. Currently, curation includes documentation, preservation, physical security, preparation, and distribution of samples from the Moon, asteroids, comets, the solar wind, and the planet Mars. Each of these sample sets has a unique history and comes from a unique environment. The curation laboratories and procedures developed over 40 years have proven both necessary and sufficient to serve the evolving needs of a worldwide research community. A new generation of sample return missions to destinations across the solar system is being planned and proposed. The curators are developing the tools and techniques to meet the challenges of these new samples. Extraterrestrial samples pose unique curation requirements. These samples were formed and exist under conditions strikingly different from those on the Earth's surface. Terrestrial contamination would destroy much of the scientific significance of extraterrestrial materials. To preserve the research value of these precious samples, contamination must be minimized, understood, and documented. In addition, the samples must be preserved - as far as possible - from physical and chemical alteration. The elaborate curation facilities at JSC were designed and constructed, and have been operated for many years, to keep sample contamination and alteration to a minimum. Currently, JSC curates seven collections of extraterrestrial samples: (a)) Lunar rocks and soils collected by the Apollo astronauts, (b) Meteorites collected on dedicated expeditions to Antarctica, (c) Cosmic dust collected by high-altitude NASA aircraft,t (d) Solar wind atoms collected by the Genesis spacecraft, (e) Comet particles collected by the Stardust spacecraft, (f) Interstellar dust particles collected by the Stardust spacecraft, and (g) Asteroid soil particles collected by the Japan Aerospace Exploration Agency (JAXA) Hayabusa spacecraft Each of these sample sets has a unique history and comes from a unique environment. We have developed specialized laboratories and practices over many years to preserve and protect the samples, not only for current research but for studies that may be carried out in the indefinite future.

  17. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; in-bottle acid digestion of whole-water samples

    USGS Publications Warehouse

    Hoffman, G.L.; Fishman, M. J.; Garbarino, J.R.

    1996-01-01

    Water samples for trace-metal determinations routinely have been prepared in open laboratories. For example, the U.S. Geological Survey method I-3485-85 (Extraction Procedure, for Water- Suspended Sediment) is performed in a laboratory hood on a laboratory bench without any special precautions to control airborne contamination. This method tends to be contamination prone for several trace metals primarily because the samples are transferred, acidified, digested, and filtered in an open laboratory environment. To reduce trace-metal contamination of digested water samples, procedures were established that rely on minimizing sample-transfer steps and using a class-100 clean bench during sample filtration. This new procedure involves the following steps: 1. The sample is acidified with HCl directly in the original water-sample bottle. 2. The water-sample bottle with the cap secured is heated in a laboratory oven. 3. The digestate is filtered in a class-100 laminar-flow clean bench. The exact conditions used (that is, oven temperature, time of heating, and filtration methods) for this digestion procedure are described. Comparisons between the previous U.S Geological Survey open-beaker method I-3485-85 and the new in-bottle procedure for synthetic and field-collected water samples are given. When the new procedure is used, blank concentrations for most trace metals determined are reduced significantly.

  18. The Environmental Measurements Laboratory's Stratospheric Radionuclide (RANDAB) and Trace Gas (TRACDAB) Databases

    DOE Data Explorer

    Leifer, Robert [Environmental Measurements Lab. (EML), New York, NY (United States); Chan, Nita [Environmental Measurements Lab. (EML), New York, NY (United States)

    1997-01-01

    RANDAB represents the worlds largest collection of stratospheric and upper tropospheric radionuclide data. The database contains results of measurements made from 1957 to 1983 during the ASHCAN, STARDUST, AIRSTREAM, and High Altitude Sampling Program (HASP) projects. More than 20,000 filters were collected during this period and analyzed for approximately 40 different radionuclides. All of the available data characterizing each filter are included in RANDAB. RANDAB offers gas samples characterizing the tritium, radon and 14CO2 concentration in stratospheric air. Only a limited amount of data is available for radon because of analytical and sampling problems. The tritium data were provided graciously by Dr. Allen Mason of Los Alamos Laboratory and Dr. H. G. Oslund of the Tritium Laboratory, University of Miami. The second database, TRACDAB, contains more than 1000 stratospheric trace gas measurements for the period 1974 to 1983. These samples were collected during Project AIRSTREAM. During the years 1974 to 1976, the samples were analyzed at EML. Subsequently, Washington State University (1976-1979) and the Oregon Graduate Institute for Science & Technology (formerly the Oregon Graduate Center 1980-1983) were under contract to EML to analyze AIRSTREAM gas samples. During the period 1974-1983, 980 gas samples were analyzed for one or more of the following gases CCl3F, CCl2F2, CCl4, CH3CCl3, SF6, N20, CO2, CH4, and carbonyl sulfide (COS). To learn more about the naming of halocarbons (CFCs, HFCs, HCFCs, and halons), go to http://cdiac.ess-dive.lbl.gov/pns/cfcinfo.html.

  19. Research and development of a field-ready protocol for sampling of phosgene from stationary source emissions: Diethylamine reagent studies. Research report, 11 July 1995--30 September 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steger, J.L.; Bursey, J.T.; Merrill, R.G.

    1999-03-01

    This report presents the results of laboratory studies to develop and evaluate a method for the sampling and analysis of phosgene from stationary sources of air emissions using diethylamine (DEA) in toluene as the collection media. The method extracts stack gas from emission sources and stabilizes the reactive gas for subsequent analysis. DEA was evaluated both in a benchtop study and in a laboratory train spiking study. This report includes results for both the benchtop study and the train spiking study. Benchtop studies to evaluate the suitability of DEA for collecting and analyzing phosgene investigated five variables: storage time, DEAmore » concentration, moisture/pH, phosgene concentration, and sample storage temperature. Prototype sampling train studies were performed to determine if the benchtop chemical studies were transferable to a Modified Method 5 sampling train collecting phosgene in the presence of clean air mixed with typical stack gas components. Four conditions, which varied the moisture and phosgene spike were evaluated in triplicate. In addition to research results, the report includes a detailed draft method for sampling and analysis of phosgene from stationary source emissions.« less

  20. FIELD COLLECTION METHODS USED IN THE EPA NATIONAL EXPOSURE RESEARCH LABORATORY HUMAN EXPOSURE MEASUREMENT PROGRAM TO EVALUATE CHILDREN'S AGGREGATE EXPOSURE TO PESTICIDES: A TUTORIAL

    EPA Science Inventory

    A tutorial on the field sampling equipment used to collect multimedia samples.

    We conduct observational human exposure measurement studies in order to understand what chemicals people come into contact with, at what levels, what the sources of those chemicals are, and wher...

  1. Central Colorado Assessment Project (CCAP)-Geochemical data for rock, sediment, soil, and concentrate sample media

    USGS Publications Warehouse

    Granitto, Matthew; DeWitt, Ed H.; Klein, Terry L.

    2010-01-01

    This database was initiated, designed, and populated to collect and integrate geochemical data from central Colorado in order to facilitate geologic mapping, petrologic studies, mineral resource assessment, definition of geochemical baseline values and statistics, environmental impact assessment, and medical geology. The Microsoft Access database serves as a geochemical data warehouse in support of the Central Colorado Assessment Project (CCAP) and contains data tables describing historical and new quantitative and qualitative geochemical analyses determined by 70 analytical laboratory and field methods for 47,478 rock, sediment, soil, and heavy-mineral concentrate samples. Most samples were collected by U.S. Geological Survey (USGS) personnel and analyzed either in the analytical laboratories of the USGS or by contract with commercial analytical laboratories. These data represent analyses of samples collected as part of various USGS programs and projects. In addition, geochemical data from 7,470 sediment and soil samples collected and analyzed under the Atomic Energy Commission National Uranium Resource Evaluation (NURE) Hydrogeochemical and Stream Sediment Reconnaissance (HSSR) program (henceforth called NURE) have been included in this database. In addition to data from 2,377 samples collected and analyzed under CCAP, this dataset includes archived geochemical data originally entered into the in-house Rock Analysis Storage System (RASS) database (used by the USGS from the mid-1960s through the late 1980s) and the in-house PLUTO database (used by the USGS from the mid-1970s through the mid-1990s). All of these data are maintained in the Oracle-based National Geochemical Database (NGDB). Retrievals from the NGDB and from the NURE database were used to generate most of this dataset. In addition, USGS data that have been excluded previously from the NGDB because the data predate earliest USGS geochemical databases, or were once excluded for programmatic reasons, have been included in the CCAP Geochemical Database and are planned to be added to the NGDB.

  2. Policies and practices in haemostasis testing among laboratories in Croatia: a survey on behalf of a Working Group for Laboratory Coagulation of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Bronić, Ana; Herak, Desiree Coen; Margetić, Sandra; Milić, Marija

    2017-02-15

    The objective of this survey was to assess current policies and practice in haemostasis testing among both hospital and outpatient laboratories in Republic of Croatia. A questionnaire with seventy questions divided into nine sections was created in May 2015. Participants were asked about their practice related to test request form, sample collection, prothrombin time (PT) and activated partial thromboplastin time assays, other individual haemostasis assays, point-of-care testing (POCT), reporting of coagulation tests results and quality assurance of procedures, the personnel and other laboratory resources, as well as on issues related to education and implementation of additional coagulation assays in their laboratory. The survey was administered and data were collected between June and September 2015. A total survey response rate was 104/170 (61.2%). Most respondents were faced with incomplete information on prescribed therapy and diagnosis on the test request or inappropriate samples withdrawn on distant locations, but also do not have protocols for handling samples with high haematocrit values. Reporting of PT-INR and D-dimer results was different between laboratories. Although almost all laboratories developed a critical value reporting system, reporting a value to general practitioners is still a problem. Result on coagulation POCT testing showed that not all devices were supervised by laboratories, which is not in compliance with Croatian Chamber of Medical Biochemistry acts. Obtained results highlighted areas that need improvement and different practice patterns in particular field of haemostasis testing among laboratories. A harmonization of the overall process of haemostasis testing at national level should be considered and undertaken.

  3. Policies and practices in haemostasis testing among laboratories in Croatia: a survey on behalf of a Working Group for Laboratory Coagulation of the Croatian Society of Medical Biochemistry and Laboratory Medicine

    PubMed Central

    Bronić, Ana; Herak, Desiree Coen; Margetić, Sandra; Milić, Marija

    2017-01-01

    Introduction The objective of this survey was to assess current policies and practice in haemostasis testing among both hospital and outpatient laboratories in Republic of Croatia. Materials and methods A questionnaire with seventy questions divided into nine sections was created in May 2015. Participants were asked about their practice related to test request form, sample collection, prothrombin time (PT) and activated partial thromboplastin time assays, other individual haemostasis assays, point-of-care testing (POCT), reporting of coagulation tests results and quality assurance of procedures, the personnel and other laboratory resources, as well as on issues related to education and implementation of additional coagulation assays in their laboratory. The survey was administered and data were collected between June and September 2015. Results A total survey response rate was 104/170 (61.2%). Most respondents were faced with incomplete information on prescribed therapy and diagnosis on the test request or inappropriate samples withdrawn on distant locations, but also do not have protocols for handling samples with high haematocrit values. Reporting of PT-INR and D-dimer results was different between laboratories. Although almost all laboratories developed a critical value reporting system, reporting a value to general practitioners is still a problem. Result on coagulation POCT testing showed that not all devices were supervised by laboratories, which is not in compliance with Croatian Chamber of Medical Biochemistry acts. Conclusion Obtained results highlighted areas that need improvement and different practice patterns in particular field of haemostasis testing among laboratories. A harmonization of the overall process of haemostasis testing at national level should be considered and undertaken. PMID:28392741

  4. Radionuclides, inorganic constituents, organic compounds, and bacteria in water from selected wells and springs from the southern boundary of the Idaho National Engineering Laboratory to the Hagerman Area, Idaho, 1990

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartholomay, R.C.; Edwards, D.D.; Campbell, L.J.

    1992-03-01

    The US Geological Survey and the Idaho Department of Water Resources, in response to a request from the US Department of Energy, sampled 19 sites as part of a long-term project to monitor water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering Laboratory to the Hagerman area. Water samples were collected and analyzed for manmade pollutants and naturally occurring constituents. The samples were collected from seven irrigation wells, five domestic wells, two springs, one stock well, two dairy wells, one observation well, and one commercial well. Two quality assurance samples also weremore » collected and analyzed. The water samples were analyzed for selected radionuclides, inorganic constituents, organic compounds, and bacteria. None of the radionuclides, inorganic constituents, or organic compounds exceeded the established maximum contaminant levels for drinking water. Most of the radionuclide and inorganic constituent concentrations exceeded their respective reporting levels. All samples analyzed for surfactants and dissolved organic carbon had concentrations that exceeded their reporting level. Toluene concentrations exceeded the reporting level in one water sample. Two samples contained fecal coliform bacteria counts that exceeded established maximum contaminant levels for drinking water.« less

  5. DEVELOPMENT, EVALUATION AND APPLICATION OF AN AUTOMATED EVENT PRECIPITATION SAMPLER FOR NETWORK OPERATION

    EPA Science Inventory

    In 1993, the University of Michigan Air Quality Laboratory (UMAQL) designed a new wet-only precipitation collection system that was utilized in the Lake Michigan Loading Study. The collection system was designed to collect discrete mercury and trace element samples on an event b...

  6. Water-chemistry data for selected springs, geysers, and streams in Yellowstone National Park, Wyoming, 2006-2008

    USGS Publications Warehouse

    Ball, James W.; McMleskey, R. Blaine; Nordstrom, D. Kirk

    2010-01-01

    Water analyses are reported for 104 samples collected from numerous thermal and non-thermal features in Yellowstone National Park (YNP) during 2006-2008. Water samples were collected and analyzed for major and trace constituents from 10 areas of YNP including Apollinaris Spring and Nymphy Creek along the Norris-Mammoth corridor, Beryl Spring in Gibbon Canyon, Norris Geyser Basin, Lower Geyser Basin, Crater Hills, the Geyser Springs Group, Nez Perce Creek, Rabbit Creek, the Mud Volcano area, and Washburn Hot Springs. These water samples were collected and analyzed as part of research investigations in YNP on arsenic, antimony, iron, nitrogen, and sulfur redox species in hot springs and overflow drainages, and the occurrence and distribution of dissolved mercury. Most samples were analyzed for major cations and anions, trace metals, redox species of antimony, arsenic, iron, nitrogen, and sulfur, and isotopes of hydrogen and oxygen. Analyses were performed at the sampling site, in an on-site mobile laboratory vehicle, or later in a U.S. Geological Survey laboratory, depending on stability of the constituent and whether it could be preserved effectively. Water samples were filtered and preserved on-site. Water temperature, specific conductance, pH, emf (electromotive force or electrical potential), and dissolved hydrogen sulfide were measured on-site at the time of sampling. Dissolved hydrogen sulfide was measured a few to several hours after sample collection by ion-specific electrode on samples preserved on-site. Acidity was determined by titration, usually within a few days of sample collection. Alkalinity was determined by titration within 1 to 2 weeks of sample collection. Concentrations of thiosulfate and polythionate were determined as soon as possible (generally a few to several hours after sample collection) by ion chromatography in an on-site mobile laboratory vehicle. Total dissolved iron and ferrous iron concentrations often were measured on-site in the mobile laboratory vehicle. Concentrations of dissolved aluminum, arsenic, boron, barium, beryllium, calcium, cadmium, cobalt, chromium, copper, iron, potassium, lithium, magnesium, manganese, molybdenum, sodium, nickel, lead, selenium, silica, strontium, vanadium, and zinc were determined by inductively coupled plasma-optical emission spectrometry. Trace concentrations of dissolved antimony, cadmium, cobalt, chromium, copper, lead, and selenium were determined by Zeeman-corrected graphite-furnace atomic-absorption spectrometry. Dissolved concentrations of total arsenic, arsenite, total antimony, and antimonite were determined by hydride generation atomic-absorption spectrometry using a flow-injection analysis system. Dissolved concentrations of total mercury and methylmercury were determined by cold-vapor atomic fluorescence spectrometry. Concentrations of dissolved chloride, fluoride, nitrate, bromide, and sulfate were determined by ion chromatography. For many samples, concentrations of dissolved fluoride also were determined by ion-specific electrode. Concentrations of dissolved ferrous and total iron were determined by the FerroZine colorimetric method. Concentrations of dissolved ammonium were determined by ion chromatography, with reanalysis by colorimetry when separation of sodium and ammonia peaks was poor. Dissolved organic carbon concentrations were determined by the wet persulfate oxidation method. Hydrogen and oxygen isotope ratios were determined using the hydrogen and CO2 equilibration techniques, respectively.

  7. Characterization of Gas and Particle Emissions from Laboratory Burns of Peat

    EPA Science Inventory

    Peat cores collected from two locations in eastern North Carolina (NC, USA) were burned in a laboratory facility to characterize emissions during simulated field combustion. Particle and gas samples were analyzed to quantify emission factors for particulate matter (PM2.5), organi...

  8. SOIL AND FILL LABORATORY SUPPORT - 1991

    EPA Science Inventory

    The report gives results of soil analysis laboratory work by the University of Florida in Support of the Florida Radon Research Program (FRRP). Analyses were performed on soil and fill samples collected during 1991 by the FRRP Research House program and the New House Evaluation P...

  9. CTEPP-OH DATA SUPPLEMENTAL INFORMATION ON FIELD AND LABORATORY SAMPLES

    EPA Science Inventory

    This data set contains supplemental data related to the final core analytical results table for CTEPP-OH. This includes sample collection data for example sample weight, air volume, creatinine, specific gravity etc.

    The Children’s Total Exposure to Persistent Pesticides and Oth...

  10. Blood meal analysis of tabanid fly after it biting the rare Sumatran rhinoceros

    PubMed Central

    Rovie-Ryan, Jeffrine Japning; Zainuddin, Zainal Zahari; Marni, Wahap; Ahmad, Abdul Hamid; Ambu, Laurentius N.; Payne, Junaidi

    2013-01-01

    Objective To demonstrate a noninvasive large mammalian genetic sampling method using blood meal obtained from a tabanid fly. Methods Blood meal was recovered from the abdomen of an engorged tabanid fly (Haematopota sp.) which was captured immediately after biting a Sumatran rhino in captivity. The blood was applied on to a Whatman FTA® blood card. Subsequent laboratory work was conducted to extract, amplify and sequence the DNA from the sample. Validation was done by sampling the hair follicles and blood samples from the rhinoceros and subjecting it to the same laboratory process. Results BLAST search and constructed phylogenetic trees confirmed the blood meal samples were indeed from the rhino. Conclusions This method could be used in the field application to noninvasively collect genetic samples. Collection of tabanids and other haematophagous arthropods (e.g. mosquitoes and ticks) and other blood-sucking parasites (e.g. leeches and worms) could also provide information on vector-borne diseases. PMID:23593586

  11. Avian toxicologic diagnosis

    USGS Publications Warehouse

    Sigurdson, C.J.; Franson, J.C.; Fudge, A.M.

    2000-01-01

    This chapter describes the sources and pathophysiology of some potential poisons that affect birds and summarizes useful laboratory tests. The diagnosis of poisoning in birds, as in mammals, requires a complete and accurate history, careful observation of clinical signs, and a thorough necropsy evaluation. Appropriate sample handling and analysis, based on consultation with the diagnostic toxicologist, are critical (Table 19--1). Veterinary toxicology laboratories are becoming increasingly specialized, with only certain laboratories capable of analyzing for drug residues or anticoagulants, for example. Although a local laboratory may not be able to fulfill a specific test request, they may recommend an alternative laboratory or may be willing to forward the sample. As a general rule in suspect poisoning cases, large tissue samples of liver, kidney, brain, and subcutaneous fat and of crop, proventriculus, and ventriculus contents should be collected at necropsy and frozen. Appropriate samples should be submitted frozen, with the remainder held in the freezer for possible later testing. A second set of tissues should be placed in 10% formalin for histopathologic examination.

  12. The snowmaker: nature identical snow production in the laboratory

    NASA Astrophysics Data System (ADS)

    Schleef, S.; Jaggi, M.; Loewe, H.; Schneebeli, M.

    2013-12-01

    Using natural snow for laboratory experiments can be tricky due to shortage of winter periods and snowfall, difficulties of sample casting and transport, and the great variability of natural snow due to the varying conditions of crystal growth in the clouds. This hinders repeatable laboratory experiments with reproducible specimen and microstructural characteristics. To minimize experimental uncertainties we designed an improved machine called snowmaker, which enables us to produce nature-identical snow in a cold laboratory under well defined conditions. The snowmaker is based on well-known principles: warm humid air from a heated water basin is advected into a cold nucleation chamber where the vapor resublimates on stretched Nylon wires. Crystals are automatically harvested by a motor driven brush rack and collected in a box, thereby several kilograms of snow can be produced per day with minimum maintenance. The excess vapor is collected in a moisture trap to avoid frost in the laboratory. The entire construction is designed as a rolling, modular assembly system which can easily carried out of the laboratory for defrosting. In addition to previous attempts we focus on the reproducibility of the samples and the comparison to natural snow down to the microscale. We show that the settings of water temperature and cold laboratory temperature facilitates the production of different crystal shapes like dendrites and needles in a reproducible way. Besides photography, we analyzed the microstructure of snowmaker crystals in aggregated specimen by X-ray microtomography. Depending on the settings we can create reproducible samples with density of 50-170 kg/m3 and specific surface areas of 50-80 mm-1. We briefly touch similarities between artificial and natural snow samples with respect to crystal habit, microstructural parameters and short-time metamorphism.

  13. Collection, transport and general processing of clinical specimens in Microbiology laboratory.

    PubMed

    Sánchez-Romero, M Isabel; García-Lechuz Moya, Juan Manuel; González López, Juan José; Orta Mira, Nieves

    2018-02-06

    The interpretation and the accuracy of the microbiological results still depend to a great extent on the quality of the samples and their processing within the Microbiology laboratory. The type of specimen, the appropriate time to obtain the sample, the way of sampling, the storage and transport are critical points in the diagnostic process. The availability of new laboratory techniques for unusual pathogens, makes necessary the review and update of all the steps involved in the processing of the samples. Nowadays, the laboratory automation and the availability of rapid techniques allow the precision and turn-around time necessary to help the clinicians in the decision making. In order to be efficient, it is very important to obtain clinical information to use the best diagnostic tools. Copyright © 2018 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  14. Transmission efficiency of the sigma virus in natural populations of its host, Drosophila melanogaster.

    PubMed

    Fleuriet, A

    1982-01-01

    A study of the viral samples collected in French natural populations of Drosophila melanogaster since 1969, indicates that natural populations include, as expected, both stabilized and non stabilized infected individuals. In agreement with previous observations made on other characters of the virus, the viral samples collected appear to be homogeneous for the efficiency of the hereditary transmission. However, this efficiency is greater than the average value observed with virus perpetuated in infected laboratory fly strains. One sample collected in Gabon and three in the U.S.A. appear to differ from the French samples for one at least of the traits studied in these experiments.

  15. Toxicological Assessment of ISS Air Quality: June - September 2013 (Increment 36)

    NASA Technical Reports Server (NTRS)

    Meyers, Valerie

    2014-01-01

    Fourteen mini grab sample containers (msGSCs) were collected on ISS between June and September 2013 and were returned on 34S; however, the ATV-4 first ingress mGSC did not contain sufficient sample to report results (initial sample pressure = 1.2 psia). Of the remaining 13 mGSCs, 12 were collected as routine monthly samples in the Russian Service Module (SM), US Laboratory (Lab), and either the Japanese Pressurized Module (JPM) or the Columbus module (Col), and 1 was collected during HTV-4 first ingress. A summary of the analytical results from the 13 valid mGSCs is shown.

  16. Atmospheric Methane Mixing Ratios--The NOAA/CMDL Global Cooperative Air Sampling Network\\, 1983-1993

    DOE Data Explorer

    Dlugokencky, E. J. [National Oceanic and Atmospheric Administration, Boulder, Colorado (USA); Lang, P. M. [National Oceanic and Atmospheric Administration, Boulder, Colorado (USA); Masarie, K. A. [National Oceanic and Atmospheric Administration, Boulder, Colorado (USA); Steele, L. P. [Commonwealth Scientific and Industrial Research Organisation, Aspendale, Victoria, Australia

    1994-01-01

    This data base presents atmospheric methane (CH4) mixing ratios from flask air samples collected over the period 1983-1993 by the National Oceanic and Atmospheric Administration, Climate Monitoring and Diagnostics Laboratory's (NOAA/CMDL's) global cooperative air sampling network. Air samples were collected approximately once per week at 44 fixed sites (37 of which were still active at the end of 1993). Samples were also collected at 5 degree latitude intervals along shipboard cruise tracks in the Pacific Ocean between North America and New Zealand (or Australia) and at 3 degree latitude intervals along cruise tracks in the South China Sea between Singapore and Hong Kong. The shipboard measurements were made approximately every 3 weeks per latitude zone by each of two ships in the Pacific Ocean and approximately once every week per latitude zone in the South China Sea. All samples were analyzed for CH4 at the NOAA/CMDL laboratory in Boulder, Colorado, by gas chromatography with flame ionization detection, and each aliquot was referenced to the NOAA/CMDL methane standard scale. In addition to providing the complete set of atmospheric CH4 measurements from flask air samples collected at the NOAA/CMDL network sites, this data base also includes files which list monthly mean mixing ratios derived from the individual flask air measurements. These monthly summary data are available for 35 of the fixed sites and 21 of the shipboard sampling sites.

  17. Looking for Microbes in a Spacecraft Assembly Clean Room

    NASA Image and Video Library

    2013-11-06

    A microbiologist collects a swab sample from the floor of a spacecraft assembly clean room at NASA Jet Propulsion Laboratory where samples such as this are taken frequently during the assembly of a spacecraft and analyzed.

  18. Nitrate Waste Treatment Sampling and Analysis Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vigil-Holterman, Luciana R.; Martinez, Patrick Thomas; Garcia, Terrence Kerwin

    2017-07-05

    This plan is designed to outline the collection and analysis of nitrate salt-bearing waste samples required by the New Mexico Environment Department- Hazardous Waste Bureau in the Los Alamos National Laboratory (LANL) Hazardous Waste Facility Permit (Permit).

  19. The role of the medical laboratory technologist in drinking and driving cases. Part 1: The Criminal Code and blood collection for alcohol analysis.

    PubMed

    Westenbrink, W

    1992-01-01

    Police officers can now demand blood samples from suspected impaired drivers in Canada to determine their Blood Alcohol Concentration. The medical laboratory technologist has been given the authority to take blood samples for legal purposes, as well as the authorization to complete certificates used as evidence in court. The proper procedures for the taking of blood samples and the completion of certificates are described in detail. The Criminal Code offences dealing with drinking and driving, the means by which police officers can legally obtain blood samples, the Blood Alcohol Kit, and the provision of providing blood collection evidence in court are discussed to aid the technologists in understanding their role in this process. The Criminal Code definitions of a "qualified medical practitioner", a "qualified technician", and "approved containers" are also described.

  20. Home dim light melatonin onsets with measures of compliance in delayed sleep phase disorder.

    PubMed

    Burgess, Helen J; Park, Margaret; Wyatt, James K; Fogg, Louis F

    2016-06-01

    The dim light melatonin onset (DLMO) assists with the diagnosis and treatment of circadian rhythm sleep disorders. Home DLMOs are attractive for cost savings and convenience, but can be confounded by home lighting and sample timing errors. We developed a home saliva collection kit with objective measures of light exposure and sample timing. We report on our first test of the kit in a clinical population. Thirty-two participants with delayed sleep phase disorder (DSPD; 17 women, aged 18-52 years) participated in two back-to-back home and laboratory phase assessments. Most participants (66%) received at least one 30-s epoch of light >50 lux during the home phase assessments, but for only 1.5% of the time. Most participants (56%) collected every saliva sample within 5 min of the scheduled time. Eighty-three per cent of home DLMOs were not affected by light or sampling errors. The home DLMOs occurred, on average, 10.2 min before the laboratory DLMOs, and were correlated highly with the laboratory DLMOs (r = 0.93, P < 0.001). These results indicate that home saliva sampling with objective measures of light exposure and sample timing, can assist in identifying accurate home DLMOs. © 2016 European Sleep Research Society.

  1. Comparison of stool collection on site versus at home in a population-based study : feasibility and participants' preference in Pretest 2 of the German National Cohort.

    PubMed

    Schultze, A; Akmatov, M K; Andrzejak, M; Karras, N; Kemmling, Y; Maulhardt, A; Wieghold, S; Ahrens, W; Günther, K; Schlenz, H; Krause, G; Pessler, F

    2014-11-01

    For certain laboratory investigations it is necessary to obtain native stool samples and process them within a narrow time window at the point of contact or a nearby laboratory. However, it is not known whether it is feasible to obtain stool samples from asymptomatic individuals during an appointment in a study center (SC). We therefore compared participants' preference, feasibility and acceptance of stool sample collection during the appointment at the study center (on-site sampling) to collection at home after the appointment. The study was conducted at two sites in Northern Germany (Bremen, n = 156; Hannover, n = 147) during the Pretest 2 phase of the German National Cohort (GNC), drawing upon a randomly selected population supplemented by a small convenience sample. In the study center, the participants were given the choice to provide a stool sample during the appointment or to collect a sample later at home and return it by mail. In all, 303 of the 351 participants (86 %) of Pretest 2 at these sites participated in this feasibility study. Only 7.9 % (24/303) of the participants chose on-site collection, whereas 92 % (279/303) chose at-home collection. There were significant differences between the two study sites in that 14 % (21/147) of participants in Hannover and 2 % (3/156) of participants in Bremen chose on-site collection. Compliance was high in both groups, as 100 % (24/24) and 98 % (272/279) of participants in the on-site and at-home groups, respectively, provided complete samples. Both methods were highly accepted, as 92 % of the participants in each group (22/24 and 227/248) stated that stool collection at the respective site was acceptable. When given a choice, most participants in this population-based study preferred home collection of stool samples to collection in the study center. Thus, native stool samples for immediate processing in the study center may potentially be obtained only from a subpopulation of participants, which may lead to selection bias. Home collection, on the other hand, proved to be a highly feasible method for studies that do not require freshly collected native stool.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Puls, R.W.; Powell, R.M.

    R.S. Kerr Environmental Research Laboratory (RSKERL) personnel have evaluated sampling procedures for the collection of representative, accurate, and reproducible ground water quality samples for metals for the past four years. Intensive sampling research at three different field sites has shown that the method by which samples are collected has a greater impact on sample quality, accuracy, and reproducibility than whether the samples are filtered or not. In particular, sample collection practices that induce artifically high levels of turbidity have been shown to have the greatest negative impacts on sample quality. Results indicated the ineffectiveness of bailer for collection of representativemore » metal samples. Inconsistent operator usage together with excessive purging generally resulted in excessive turbidity and large differences in filtered and unfiltered metal samples. The use of low flow rate purging and sampling consistently produced filtered and unfiltered samples that showed no significant differences in concentrations. Turbidity levels were generally less than 5 NTUs, even in fine-textured glacial till. The authors recommend the use of low flow rates, during both purging and sampling.« less

  3. An operation manual for a time-series, storm-activated suspended sediment sampler deployed in the coastal ocean: function, maintenance, and testing procedures

    USGS Publications Warehouse

    Rendigs, Richard R.; Bothner, Michael H.

    2004-01-01

    This manual describes the operation and testing procedures for two models of a multi-port suspended sediment sampler that are moored in the coastal ocean and that collect samples on a programmable time schedule that can be interrupted to collect during a storm. The ability to sense and collect samples before, during, and after the height of a storm is a unique feature of these instruments because it provides samples during conditions when it is difficult or impossible to sample from a surface ship. The sensors used to trigger storm sampling are a transmissometer or a pressure sensor. The purpose of such samples is to assess composition and concentration of sediment resuspended from the seafloor during storms and subsequently transported within the coastal system. Both light transmission and the standard deviation of pressure from surface waves correlate with the passage of major storms. The instruments successfully identified the onset of storms and collected samples before, during, and after the storm maximum as programmed. The accuracy of determining suspended matter concentrations collected by the sediment sampler has not been fully evaluated. Preliminary laboratory tests using a suspension of muddy sediment collected in a near-bottom sediment trap yielded excellent results. However in laboratory tests with different sediment types, the suspended matter concentrations determined with these samplers became less accurate with increasing average grain size. Future calibration work is necessary and should be conducted in a facility that ideally has a water depth of at least 30 feet to prevent cavitation of the pump that draws sea water through the filters. The test facility should also have the capability for adding suspended matter of known composition and concentration to a fixed volume of seawater that is well mixed.

  4. Radionuclides, inorganic constituents, organic compounds, and bacteria in water from selected wells and springs from the southern boundary of the Idaho National Engineering Laboratory to the Hagerman Area, Idaho, 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartholomay, R.C.; Edwards, D.D.; Campbell, L.J.

    1993-11-01

    The US Geological Survey and the Idaho Department of Water Resources, in response to a request from the US Department of Energy, sampled 18 sites as part of a long-term project to monitor water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering Laboratory to the Hagerman area. Water samples were collected and analyzed for manmade pollutants and naturally occurring constituents. The samples were collected from six irrigation wells, seven domestic wells, two springs, one stock well, one dairy well, and one observation well. Quality assurance samples also were collected and analyzed. Themore » water samples were analyzed for selected radionuclides, inorganic constituents, organic compounds, and bacteria. None of the samples analyzed for radionuclides, inorganic constituents, or organic compounds exceeded the established maximum contaminant levels for drinking water. Most of the radionuclide and inorganic constituent concentrations exceeded their respective reporting levels. All the samples analyzed for dissolved organic carbon had concentrations that exceeded their reporting level. Concentrations of 1,1,1 -trichloroethane exceeded the reporting level in two water samples. Two samples and a quality assurance replicate contained reportable concentrations of 2, 4-D. One sample contained fecal coliform bacteria counts that exceeded established maximum contaminant levels for drinking water.« less

  5. A New Approach to Standardize Multicenter Studies: Mobile Lab Technology for the German Environmental Specimen Bank

    PubMed Central

    Lermen, Dominik; Schmitt, Daniel; Bartel-Steinbach, Martina; Schröter-Kermani, Christa; Kolossa-Gehring, Marike; von Briesen, Hagen; Zimmermann, Heiko

    2014-01-01

    Technical progress has simplified tasks in lab diagnosis and improved quality of test results. Errors occurring during the pre-analytical phase have more negative impact on the quality of test results than errors encountered during the total analytical process. Different infrastructures of sampling sites can highly influence the quality of samples and therewith of analytical results. Annually the German Environmental Specimen Bank (ESB) collects, characterizes, and stores blood, plasma, and urine samples of 120–150 volunteers each on four different sampling sites in Germany. Overarching goal is to investigate the exposure to environmental pollutants of non-occupational exposed young adults combining human biomonitoring with questionnaire data. We investigated the requirements of the study and the possibility to realize a highly standardized sampling procedure on a mobile platform in order to increase the required quality of the pre-analytical phase. The results lead to the development of a mobile epidemiologic laboratory (epiLab) in the project “Labor der Zukunft” (future’s lab technology). This laboratory includes a 14.7 m2 reception area to record medical history and exposure-relevant behavior, a 21.1 m2 examination room to record dental fillings and for blood withdrawal, a 15.5 m2 biological safety level 2 laboratory to process and analyze samples on site including a 2.8 m2 personnel lock and a 3.6 m2 cryofacility to immediately freeze samples. Frozen samples can be transferred to their final destination within the vehicle without breaking the cold chain. To our knowledge, we herewith describe for the first time the implementation of a biological safety laboratory (BSL) 2 lab and an epidemiologic unit on a single mobile platform. Since 2013 we have been collecting up to 15.000 individual human samples annually under highly standardized conditions using the mobile laboratory. Characterized and free of alterations they are kept ready for retrospective analyses in their final archive, the German ESB. PMID:25141120

  6. A new approach to standardize multicenter studies: mobile lab technology for the German Environmental Specimen Bank.

    PubMed

    Lermen, Dominik; Schmitt, Daniel; Bartel-Steinbach, Martina; Schröter-Kermani, Christa; Kolossa-Gehring, Marike; von Briesen, Hagen; Zimmermann, Heiko

    2014-01-01

    Technical progress has simplified tasks in lab diagnosis and improved quality of test results. Errors occurring during the pre-analytical phase have more negative impact on the quality of test results than errors encountered during the total analytical process. Different infrastructures of sampling sites can highly influence the quality of samples and therewith of analytical results. Annually the German Environmental Specimen Bank (ESB) collects, characterizes, and stores blood, plasma, and urine samples of 120-150 volunteers each on four different sampling sites in Germany. Overarching goal is to investigate the exposure to environmental pollutants of non-occupational exposed young adults combining human biomonitoring with questionnaire data. We investigated the requirements of the study and the possibility to realize a highly standardized sampling procedure on a mobile platform in order to increase the required quality of the pre-analytical phase. The results lead to the development of a mobile epidemiologic laboratory (epiLab) in the project "Labor der Zukunft" (future's lab technology). This laboratory includes a 14.7 m(2) reception area to record medical history and exposure-relevant behavior, a 21.1 m(2) examination room to record dental fillings and for blood withdrawal, a 15.5 m(2) biological safety level 2 laboratory to process and analyze samples on site including a 2.8 m(2) personnel lock and a 3.6 m2 cryofacility to immediately freeze samples. Frozen samples can be transferred to their final destination within the vehicle without breaking the cold chain. To our knowledge, we herewith describe for the first time the implementation of a biological safety laboratory (BSL) 2 lab and an epidemiologic unit on a single mobile platform. Since 2013 we have been collecting up to 15.000 individual human samples annually under highly standardized conditions using the mobile laboratory. Characterized and free of alterations they are kept ready for retrospective analyses in their final archive, the German ESB.

  7. Atmospheric Carbon Monoxide Mixing Ratios NOAA Climate Monitoring and Diagnostics Laboratory Cooperative Air Sampling Network (1988-1993) (DB1011)

    DOE Data Explorer

    Novelli, P. C.; Masarie, K. A.

    1994-01-01

    Individual site files provide CO mixing ratios in parts per billion (ppb) (ppb = parts in 109 by mole fraction) based on measurements from the NOAA/CMDL Cooperative Air Sampling Network beginning 1988. Data are provided through June 1993 for stations at which the first sample was collected before July 1991. All samples were analyzed for CO at the NOAA/CMDL laboratory in Boulder by gas chromatography with mercuric oxide reduction detection, and all measurements are referenced to the CMDL CO scale (Novelli et al., 1991, Novelli et al., 1994).

  8. MAP3S precipitation chemistry network. Third periodic summary report, July 1978-December 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1980-05-01

    The MAP3S Precipitation Chemistry Network consists of eight collection sites in the northeastern United States. Precipitation event samples are collected by cooperating site operators, using specially developed sampling equipment. In this, the third periodic summary report, are listed field and concentration data for the period July 1, 1978 to December 31, 1979. Over three years' samples have been collected at most of the sites, which went into operation between September 1976 and October 1978. Samples are chemically analyzed at a central laboratory for 13 pollutant species. Weekly samples in addition to event samples were collected over a 1 1/2 yearmore » period at three sites. Analysis of one year's results indicates that there is little difference between the concentrations collected by the two methods in terms of seasonal precipitation-weighted means for all species except dissolved SO/sub 2/. Event samples tend to average about 25% higher in SO/sub 2/ than weekly samples.« less

  9. COMPARISON OF LABORATORY SUBSAMPLING METHODS OF BENTHIC SAMPLES FROM BOATABLE RIVERS USING ACTUAL AND SIMULATED COUNT DATA

    EPA Science Inventory

    We examined the effects of using a fixed-count subsample of 300 organisms on metric values using macroinvertebrate samples collected with 3 field sampling methods at 12 boatable river sites. For each sample, we used metrics to compare an initial fixed-count subsample of approxima...

  10. A Preliminary Assessment of Wet Deposition and Eposodic Transport of Total and Methyl Metcury From Low Order Blue Ridge Watersheds, S.E. U.S.A.

    Treesearch

    C.J. Allan; A. Heyes

    1998-01-01

    Abstract. Results from a preliminary sampling program designed to investigate total (THg) and methyl Hg (MeHg) deposition, cycling and transport at the Coweeta Hydrologic Laboratory western North Carolina are presented. Wet deposition samples were collected in June and July 1994 and throughfall, seep and streamwaters were intensively collected during...

  11. Evaluation of sample stability for a quantitative faecal immunochemical test and comparison of two sample collection approaches.

    PubMed

    Mellen, Samantha; de Ferrars, Maria; Chapman, Claire; Bevan, Sarah; Turvill, James; Turnock, Daniel

    2018-01-01

    Background Faecal immunochemical testing is increasingly being used to triage symptomatic patients for suspected colorectal cancer. However, there are limited data on the effect of preanalytical factors on faecal haemoglobin when measured by faecal immunochemical testing. The aim of this work was to evaluate the stability of faecal haemoglobin in faeces and to compare two methods of faecal haemoglobin sampling for faecal immunochemical testing. Methods Six patients provided faeces for faecal haemoglobin measurement which were transferred into specialized collection devices at baseline and at 1, 2, 3 and 7 days after storage at either room temperature or 4°C. A total of 137 patients returned both faeces transferred into the specialized collection device and faeces in a standard collection pot. A quantitative immunoturbidometric method was used to measure faecal haemoglobin and results were compared categorically. Discrepant results were assessed against diagnosis. Results Faecal haemoglobin concentration declined rapidly within a day of storage at room temperature but results remained ≥10 μg Hb/g faeces in 5/6 patients after two days. A faecal haemoglobin result ≥10 μg Hb/g faeces was obtained in 4/6 patients after storage for seven days at 4°C. Results obtained when patients used specialized collection devices were significantly different from results obtained when faeces was transferred into the specialized collection device in the laboratory. Conclusion There is considerable heterogeneity in the sample stability of faecal haemoglobin; therefore, samples should be transferred rapidly into specialized collection devices to prevent false-negative results. Use of collection devices by patients can lead to false-positive results compared with their use in a laboratory.

  12. Area G perimeter surface-soil and single-stage water sampling: Environmental surveillance for fiscal year 95. Progress report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Childs, M.; Conrad, R.

    1997-09-01

    ESH-19 personnel collected soil and single-stage water samples around the perimeter of Area G at Los Alamos National Laboratory (LANL) during FY 95 to characterize possible radionuclide movement out of Area G through surface water and entrained sediment runoff. Soil samples were analyzed for tritium, total uranium, isotopic plutonium, americium-241, and cesium-137. The single-stage water samples were analyzed for tritium and plutonium isotopes. All radiochemical data was compared with analogous samples collected during FY 93 and 94 and reported in LA-12986 and LA-13165-PR. Six surface soils were also submitted for metal analyses. These data were included with similar data generatedmore » for soil samples collected during FY 94 and compared with metals in background samples collected at the Area G expansion area.« less

  13. Evaluation of the BD Vacutainer Plus Urine C&S Preservative Tubes compared with nonpreservative urine samples stored at 4°C and room temperature.

    PubMed

    Eisinger, Stephen W; Schwartz, Matthew; Dam, Lisa; Riedel, Stefan

    2013-09-01

    The stability of urine specimens submitted for culture remains a challenge for many laboratories because of delays in specimen transport. We evaluated the usefulness of BD Vacutainer Plus Urine C&S Preservative Tube in ensuring specimen stability. Clinical urine specimens collected in sterile collection cups (n = 110) were plated onto sheep blood and MacConkey agar following standard laboratory procedures guidelines. Thereafter, specimens were divided into 3 storage conditions: nonpreservative, refrigerated; nonpreservative, room temperature (RT); BD Vacutainer Plus Urine C&S Preservative Tube, RT. For each sample type, additional cultures were set up at 2, 4, 24, and 48 hours. Initially, 18 specimens had no growth, 32 showed mixed skin flora, and 60 yielded at least 1 uropathogen. Increased colony counts of uropathogens were observed for nonpreserved urine samples stored at RT; these changes were statistically significant. Minor differences between refrigerated urine samples and BD Vacutainer Plus Urine C&S Preservative Tube samples were seen but were not statistically significant. The use of preservative-containing collection tubes is desirable to ensure specimen stability when prompt processing or refrigeration is not feasible.

  14. Black market products confiscated in Norway 2011-2014 compared to analytical findings in urine samples.

    PubMed

    Hullstein, Ingunn R; Malerod-Fjeld, Helle; Dehnes, Yvette; Hemmersbach, Peter

    2015-01-01

    Doping agents are widely and illicitly distributed through the Internet. Analysis of these preparations is useful in order to monitor the availability of prohibited substances on the market, and more importantly to predict which substances are expected to be found in urine samples collected from athletes and to aid clinical and forensic investigations. Based on a close collaboration with the Norwegian police and the Norwegian custom authorities, the Norwegian Doping Control Laboratory has performed analyses of confiscated material suspected of containing doping agents. The analyses were performed using gas chromatography (GC) and liquid chromatography (LC) combined with mass spectrometry (MS). The majority (67%) of the analyzed black market products contained anabolic- androgenic steroids (AAS) as expected, whereas peptide- and protein-based doping substances were identified in 28% of the preparations. The Norwegian Doping Control Laboratory receives samples collected from recreational and elite athletes in addition to samples collected in clinical and forensic investigations. The findings in the seized material reflected the findings in the urine samples analyzed regarding the anabolic steroids. Thus, analyzing material seized in Norway may give a good indication of doping agents available on the local market. Copyright © 2015 John Wiley & Sons, Ltd.

  15. ALVEOLAR BREATH SAMPLING AND ANALYSIS IN HUMAN EXPOSURE ASSESSMENT STUDIES

    EPA Science Inventory

    Alveolar breath sampling and analysis can be extremely useful in exposure assessment studies involving volatile organic compounds (VOCs). Over recent years scientists from the EPA's National Exposure Research Laboratory have developed and refined an alveolar breath collection ...

  16. The National Cohort of Dairy Farms--a data collection platform for mastitis research in Canada.

    PubMed

    Reyher, K K; Dufour, S; Barkema, H W; Des Côteaux, L; Devries, T J; Dohoo, I R; Keefe, G P; Roy, J-P; Scholl, D T

    2011-03-01

    Costs and feasibility of extensive sample collection and processing are major obstacles to mastitis epidemiology research. Studies are often consequentially limited, and fundamental mastitis researchers rarely have the opportunity to conduct their work in epidemiologically valid populations. To mitigate these limitations, the Canadian Bovine Mastitis Research Network has optimized research funds by creating a data collection platform to provide epidemiologically meaningful data for several simultaneous research endeavors. This platform consists of a National Cohort of Dairy Farms (NCDF), Mastitis Laboratory Network, and Mastitis Pathogen Culture Collection. This paper describes the implementation and operation of the NCDF, explains its sampling protocols and data collection, and documents characteristics, strengths and limitations of these data for current and potential users. The NCDF comprises 91 commercial dairy farms in 6 provinces sampled over a 2-yr period. Primarily Holstein-Friesian herds participating in Dairy Herd Improvement milk recording were selected in order to achieve a uniform distribution among 3 strata of bulk tank somatic cell counts and to reflect regional proportions of freestall housing systems. Standardized protocols were implemented for repeated milk samplings on clinical mastitis cases, fresh and randomly selected lactating cows, and cows at dry-off and after calving. Just fewer than 133,000 milk samples were collected. Demographic and production data were recorded at individual cow and farm levels. Health management data are documented and extensive questionnaire data detailing farm management and cleanliness information are also captured. The Laboratory Network represents coordinated regional mastitis bacteriology laboratories using standardized procedures. The Culture Collection archives isolates recovered from intramammary infections of cows in the NCDF and contains over 16,500 isolates, all epidemiologically cross-referenced between linked databases. The NCDF is similar to Canadian dairies in relation to mean herd size, average production, and freestall percentages. Pathogen recovery was greater than anticipated, particularly for coagulase-negative staphylococci and Corynebacterium spp. International scientists are encouraged to use this extensive archive of data and material to enhance their own mastitis research. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. Crowdsourcing for Cognitive Science – The Utility of Smartphones

    PubMed Central

    Brown, Harriet R.; Zeidman, Peter; Smittenaar, Peter; Adams, Rick A.; McNab, Fiona; Rutledge, Robb B.; Dolan, Raymond J.

    2014-01-01

    By 2015, there will be an estimated two billion smartphone users worldwide. This technology presents exciting opportunities for cognitive science as a medium for rapid, large-scale experimentation and data collection. At present, cost and logistics limit most study populations to small samples, restricting the experimental questions that can be addressed. In this study we investigated whether the mass collection of experimental data using smartphone technology is valid, given the variability of data collection outside of a laboratory setting. We presented four classic experimental paradigms as short games, available as a free app and over the first month 20,800 users submitted data. We found that the large sample size vastly outweighed the noise inherent in collecting data outside a controlled laboratory setting, and show that for all four games canonical results were reproduced. For the first time, we provide experimental validation for the use of smartphones for data collection in cognitive science, which can lead to the collection of richer data sets and a significant cost reduction as well as provide an opportunity for efficient phenotypic screening of large populations. PMID:25025865

  18. Crowdsourcing for cognitive science--the utility of smartphones.

    PubMed

    Brown, Harriet R; Zeidman, Peter; Smittenaar, Peter; Adams, Rick A; McNab, Fiona; Rutledge, Robb B; Dolan, Raymond J

    2014-01-01

    By 2015, there will be an estimated two billion smartphone users worldwide. This technology presents exciting opportunities for cognitive science as a medium for rapid, large-scale experimentation and data collection. At present, cost and logistics limit most study populations to small samples, restricting the experimental questions that can be addressed. In this study we investigated whether the mass collection of experimental data using smartphone technology is valid, given the variability of data collection outside of a laboratory setting. We presented four classic experimental paradigms as short games, available as a free app and over the first month 20,800 users submitted data. We found that the large sample size vastly outweighed the noise inherent in collecting data outside a controlled laboratory setting, and show that for all four games canonical results were reproduced. For the first time, we provide experimental validation for the use of smartphones for data collection in cognitive science, which can lead to the collection of richer data sets and a significant cost reduction as well as provide an opportunity for efficient phenotypic screening of large populations.

  19. Evaluation of field sampling and preservation methods for strontium-90 in ground water at the Idaho National Engineering Laboratory, Idaho

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cecil, L.D.; Knobel, L.L.; Wegner, S.J.

    1989-09-01

    From 1952 to 1988, about 140 curies of strontium-90 have been discharged in liquid waste to disposal ponds and wells at the INEL (Idaho National Engineering Laboratory). The US Geological Survey routinely samples ground water from the Snake River Plain aquifer and from discontinuous perched-water zones for selected radionuclides, major and minor ions, and chemical and physical characteristics. Water samples for strontium-90 analyses collected in the field are unfiltered and preserved to an approximate 2-percent solution with reagent-grade hydrochloric acid. Water from four wells completed in the Snake River Plain aquifer was sampled as part of the US Geological Survey'smore » quality-assurance program to evaluate the effect of filtration and preservation methods on strontium-90 concentrations in ground water at the INEL. The wells were selected for sampling on the basis of historical concentrations of strontium-90 in ground water. Water from each well was filtered through either a 0.45- or a 0.1-micrometer membrane filter; unfiltered samples also were collected. Two sets of filtered and two sets of unfiltered water samples were collected at each well. One set of water samples was preserved in the field to an approximate 2-percent solution with reagent-grade hydrochloric acid and the other set of samples was not acidified. 13 refs., 2 figs., 6 tabs.« less

  20. SOIL AND FILL LABORATORY SUPPORT - 1992 RADIOLOGICAL ANALYSES - FLORIDA RADON RESEARCH PROGRAM

    EPA Science Inventory

    The report gives results of soil analysis laboratory work by the University of Florida in support of the Florida Radon Research Program (FRRP). Analyses were performed on soil and fill samples collected during 1992 by the FRRP Research House Program and the New House Evaluation P...

  1. 40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... sample collection filter) differs significantly from that specified for reference method samplers as... transport is the percentage of a laboratory challenge aerosol which penetrates to the active sample filter of the candidate equivalent method sampler. (2) The active sample filter is the exclusive filter...

  2. 40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... sample collection filter) differs significantly from that specified for reference method samplers as... transport is the percentage of a laboratory challenge aerosol which penetrates to the active sample filter of the candidate equivalent method sampler. (2) The active sample filter is the exclusive filter...

  3. 40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... sample collection filter) differs significantly from that specified for reference method samplers as... transport is the percentage of a laboratory challenge aerosol which penetrates to the active sample filter of the candidate equivalent method sampler. (2) The active sample filter is the exclusive filter...

  4. 40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... sample collection filter) differs significantly from that specified for reference method samplers as... transport is the percentage of a laboratory challenge aerosol which penetrates to the active sample filter of the candidate equivalent method sampler. (2) The active sample filter is the exclusive filter...

  5. 40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... sample collection filter) differs significantly from that specified for reference method samplers as... transport is the percentage of a laboratory challenge aerosol which penetrates to the active sample filter of the candidate equivalent method sampler. (2) The active sample filter is the exclusive filter...

  6. Dust emissions of organic soils observed in the field and laboratory

    NASA Astrophysics Data System (ADS)

    Zobeck, T. M.; Baddock, M. C.; Guo, Z.; Van Pelt, R.; Acosta-Martinez, V.; Tatarko, J.

    2011-12-01

    According to the U.S. Soil Taxonomy, Histosols (also known as organic soils) are soils that are dominated by organic matter (>20% organic matter) in half or more of the upper 80 cm. These soils, when intensively cropped, are subject to wind erosion resulting in loss in crop productivity and degradation of soil, air, and water quality. Estimating wind erosion on Histosols has been determined by USDA-Natural Resources Conservation Service as a critical need for the Wind Erosion Prediction System (WEPS) model. WEPS has been developed to simulate wind erosion on agricultural land in the US, including soils with organic soil material surfaces. However, additional field measurements are needed to calibrate and validate estimates of wind erosion of organic soils using WEPS. In this study, we used a field portable wind tunnel to generate suspended sediment (dust) from agricultural surfaces for soils with a range of organic contents. The soils were tilled and rolled to provide a consolidated, friable surface. Dust emissions and saltation were measured using an isokinetic vertical slot sampler aspirated by a regulated suction source. Suspended dust was collected on filters of the dust slot sampler and sampled at a frequency of once every six seconds in the suction duct using a GRIMM optical particle size analyzer. In addition, bulk samples of airborne dust were collected using a sampler specifically designed to collect larger dust samples. The larger dust samples were analyzed for physical, chemical, and microbiological properties. In addition, bulk samples of the soils were tested in a laboratory wind tunnel similar to the field wind tunnel and a laboratory dust generator to compare field and laboratory results. For the field wind tunnel study, there were no differences between the highest and lowest organic content soils in terms of their steady state emission rate under an added abrader flux, but the soil with the mid-range of organic matter had less emission by one third. In the laboratory wind tunnel, samples with the same ratio of erodible to non-erodible aggregates as the field soils were abraded and dust emissions were observed with the same sampling system as used in the field wind tunnel. In the dust generator, 5 gm samples < 8 mm diameter of each organic soil were rotated in a 50 cm long tube and the dust generated was observed with the GRIMM during a 20 minute run. Comparisons of the field dust emission rates with the laboratory results will be presented.

  7. 77 FR 48554 - Agency Information Collection Activities: Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-14

    ... number. SUPPLEMENTARY INFORMATION: Title of Collection: Survey of Laboratory Equipment Donations for... and secondary schools. The Director * * * shall survey institutions of higher education and entities... for Research (AIR) has designed a sample of institutions of higher education (IHEs) drawn from the...

  8. Water-Chemistry Data for Selected Springs, Geysers, and Streams in Yellowstone National Park, Wyoming, 2003-2005

    USGS Publications Warehouse

    Ball, James W.; McCleskey, R. Blaine; Nordstrom, D. Kirk; Holloway, JoAnn M.

    2008-01-01

    Water analyses are reported for 157 samples collected from numerous hot springs, their overflow drainages, and Lemonade Creek in Yellowstone National Park (YNP) during 2003-2005. Water samples were collected and analyzed for major and trace constituents from ten areas of YNP including Terrace and Beryl Springs in the Gibbon Canyon area, Norris Geyser Basin, the West Nymph Creek thermal area, the area near Nymph Lake, Hazle Lake, and Frying Pan Spring, Lower Geyser Basin, Washburn Hot Springs, Mammoth Hot Springs, Potts Hot Spring Basin, the Sulphur Caldron area, and Lemonade Creek near the Solfatara Trail. These water samples were collected and analyzed as part of research investigations in YNP on arsenic, antimony, and sulfur redox distribution in hot springs and overflow drainages, and the occurrence and distribution of dissolved mercury. Most samples were analyzed for major cations and anions, trace metals, redox species of antimony, arsenic, iron, nitrogen, and sulfur, and isotopes of hydrogen and oxygen. Analyses were performed at the sampling site, in an on-site mobile laboratory vehicle, or later in a U.S. Geological Survey laboratory, depending on stability of the constituent and whether it could be preserved effectively. Water samples were filtered and preserved onsite. Water temperature, specific conductance, pH, Eh (redox potential relative to the Standard Hydrogen Electrode), and dissolved hydrogen sulfide were measured onsite at the time of sampling. Acidity was determined by titration, usually within a few days of sample collection. Alkalinity was determined by titration within 1 to 2 weeks of sample collection. Concentrations of thiosulfate and polythionate were determined as soon as possible (generally minutes to hours after sample collection) by ion chromatography in an on-site mobile laboratory vehicle. Total dissolved-iron and ferrous-iron concentrations often were measured onsite in the mobile laboratory vehicle. Concentrations of dissolved aluminum, arsenic, boron, barium, beryllium, calcium, cadmium, cobalt, chromium, copper, iron, potassium, lithium, magnesium, manganese, molybdenum, sodium, nickel, lead, selenium, silica, strontium, vanadium, and zinc were determined by inductively-coupled plasma-optical emission spectrometry. Trace concentrations of dissolved antimony, cadmium, cobalt, chromium, copper, lead, and selenium were determined by Zeeman-corrected graphite-furnace atomic-absorption spectrometry. Dissolved concentrations of total arsenic, arsenite, total antimony, and antimonite were determined by hydride-generation atomic-absorption spectrometry using a flow-injection analysis system. Dissolved concentrations of total mercury and methyl mercury were determined by cold-vapor atomic-fluorescence spectrometry. Concentrations of dissolved chloride, fluoride, nitrate, bromide, and sulfate were determined by ion chromatography. Concentrations of dissolved ferrous and total iron were determined by the FerroZine colorimetric method. Concentrations of dissolved nitrite were determined by colorimetry or chemiluminescence. Concentrations of dissolved ammonium were determined by ion chromatography, with reanalysis by colorimetry when separation of sodium and ammonia peaks was poor. Dissolved organic carbon concentrations were determined by the wet persulfate oxidation method. Hydrogen and oxygen isotope ratios were determined using the hydrogen and CO2 equilibration techniques, respectively.

  9. Radiocarbon in CO2 and Soil Organic Matter from Laboratory Incubations, Barrow, Alaska, 2012

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lydia Vaughn; Margaret Torn

    Dataset includes Delta14C measurements made from soil organic matter and CO2 from laboratory soil incubations of active layer soils collected in Barrow, Alaska in 2012. In addition to Delta14CO2, dataset CO2 production rates and carbon and nitrogen concentrations. Samples were collected from intensive study site 1 areas A, B, and C, and the site 0 and AB transects, from specified positions in high-centered, flat-centered, and low centered polygons.

  10. Radiocarbon in CO2 and Soil Organic Matter from Laboratory Incubations, Barrow, Alaska, 2014

    DOE Data Explorer

    Lydia Vaughn; Margaret Torn

    2018-02-20

    Dataset includes 14C measurements made from soil organic matter and CO2 from paired anaerobic and aerobic laboratory soil incubations of active layer soils collected in Barrow, Alaska in 2014. In addition to 14CO2, dataset includes CO2 production rates and carbon and nitrogen concentrations. Samples were collected from intensive study site 1 areas A, B, and C, and the site 0 and AB transects, from specified positions in high-centered, flat-centered, and low centered polygons.

  11. Nutrition: blood sample collection

    NASA Image and Video Library

    2007-03-20

    ISS014-E-17550 (20 March 2007) --- Astronaut Michael E. Lopez-Alegria, Expedition 14 commander and NASA space station science officer, prepares to insert a test sample in the Minus Eighty Degree Laboratory Freezer for ISS (MELFI) as part of the Nutritional Status Assessment (NUTRITION) experiment in the Destiny laboratory of the International Space Station. MELFI is a low temperature freezer facility with nominal operating temperatures of -80, -26 and +4 degrees Celsius that will preserve experiment materials over long periods.

  12. Nutrition: blood sample collection

    NASA Image and Video Library

    2007-03-20

    ISS014-E-17547 (20 March 2007) --- Astronaut Michael E. Lopez-Alegria, Expedition 14 commander and NASA space station science officer, prepares to insert a test sample in the Minus Eighty Degree Laboratory Freezer for ISS (MELFI) as part of the Nutritional Status Assessment (NUTRITION) experiment in the Destiny laboratory of the International Space Station. MELFI is a low temperature freezer facility with nominal operating temperatures of -80, -26 and +4 degrees Celsius that will preserve experiment materials over long periods.

  13. Some Data from Detection of Organics in a Rock on Mars

    NASA Image and Video Library

    2014-12-16

    Data graphed here are examples from the Sample Analysis at Mars SAM laboratory detection of Martian organics in a sample of powder that the drill on NASA Curiosity Mars rover collected from a rock target called Cumberland.

  14. Standard Operating Procedure Utilization for Tuberculosis Microscopy in Mekelle City, North Ethiopia.

    PubMed

    Weldu, Yemane; Gebru, Hagos; Kahsay, Getahun; Teweldemedhn, Gebremichael; Hagos, Yifter; Kahsay, Amlsha

    2017-01-01

    The aim of this study was to assess the utilization of standard operating procedures for acid-fast bacilli (AFB) smear microscopy. A facility-based cross-sectional study was conducted in select health institutions in Mekelle City, Ethiopia, from July 1, 2015, through August 30, 2015. Using a simple random sampling technique, 18 health facilities were included in the study. Data were collected using a standard checklist and entered into Epi Info version 3.5.4 (Centers for Disease Control and Prevention, Atlanta, GA) for editing. Analysis was done using SPSS version 20 (SPSS, Chicago, IL). Of the 18 laboratory facilities, only seven (38.9%) had a legible AFB registration book. In three (16.7%) of the laboratories, heat fixation was not applied before adding primary staining reagent. In 12 (66.7%), the staining reagents had precipitates. Two laboratories had microscopes with mechanical stages that could not move freely on both axes. Seven (38.9%) of the laboratories reported samples to be negative before examining all required fields. Most laboratories, 16 (88.9%) and 17 (94.4%), respectively, did not run positive and negative controls after new batch reagent preparation. Tuberculosis microscopy was found to be substandard with clear gaps in documentation, sample collection, and processing. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  15. Chemical and radiochemical constituents in water from wells in the vicinity of the naval reactors facility, Idaho National Engineering and Environmental Laboratory, Idaho, 1997-98

    USGS Publications Warehouse

    Bartholomay, Roy C.; Knobel, LeRoy L.; Tucker, Betty J.; Twining, Brian V.

    2000-01-01

    The U.S. Geological Survey, in response to a request from the U.S. Department of Energy?s Phtsburgh Naval Reactors Ofilce, Idaho Branch Office, sampled water from 13 wells during 1997?98 as part of a long-term project to monitor water quality of the Snake River Plain aquifer in the vicinity of the Naval Reactors Facility, Idaho National Engineering and Environmental Laboratory, Idaho. Water samples were analyzed for naturally occurring constituents and man-made contaminants. A totalof91 samples were collected from the 13 monitoring wells. The routine samples contained detectable concentrations of total cations and dissolved anions, and nitrite plus nitrate as nitrogen. Most of the samples also had detectable concentrations of gross alpha- and gross beta-particle radioactivity and tritium. Fourteen qualityassurance samples also were collected and analyze~ seven were field-blank samples, and seven were replicate samples. Most of the field blank samples contained less than detectable concentrations of target constituents; however, some blank samples did contain detectable concentrations of calcium, magnesium, barium, copper, manganese, nickel, zinc, nitrite plus nitrate, total organic halogens, tritium, and selected volatile organic compounds.

  16. International Council for Standardization in Haematology (ICSH) Recommendations for Laboratory Measurement of Direct Oral Anticoagulants.

    PubMed

    Gosselin, Robert C; Adcock, Dorothy M; Bates, Shannon M; Douxfils, Jonathan; Favaloro, Emmanuel J; Gouin-Thibault, Isabelle; Guillermo, Cecilia; Kawai, Yohko; Lindhoff-Last, Edelgard; Kitchen, Steve

    2018-03-01

    This guidance document was prepared on behalf of the International Council for Standardization in Haematology (ICSH) for providing haemostasis-related guidance documents for clinical laboratories. This inaugural coagulation ICSH document was developed by an ad hoc committee, comprised of international clinical and laboratory direct acting oral anticoagulant (DOAC) experts. The committee developed consensus recommendations for laboratory measurement of DOACs (dabigatran, rivaroxaban, apixaban and edoxaban), which would be germane for laboratories assessing DOAC anticoagulation. This guidance document addresses all phases of laboratory DOAC measurements, including pre-analytical (e.g. preferred time sample collection, preferred sample type, sample stability), analytical (gold standard method, screening and quantifying methods) and post analytical (e.g. reporting units, quality assurance). The committee addressed the use and limitations of screening tests such as prothrombin time, activated partial thromboplastin time as well as viscoelastic measurements of clotting blood and point of care methods. Additionally, the committee provided recommendations for the proper validation or verification of performance of laboratory assays prior to implementation for clinical use, and external quality assurance to provide continuous assessment of testing and reporting method. Schattauer GmbH Stuttgart.

  17. Mineralogy of Eolian Sands at Gale Crater

    NASA Technical Reports Server (NTRS)

    Achilles, C. N.; Vaniman, D. T.; Blake, D. F.; Bristow, T. F.; Rampe, E. B.; Ming, D. W.; Chipera, S. J.; Morris, R. V.; Morrison, S. M.; Downs, R. T.; hide

    2016-01-01

    The Mars Science Laboratory rover Curiosity has been exploring outcrop and regolith in Gale crater since August 6, 2012. During this exploration, the mission has collected 10 samples for mineralogical analysis by X-ray diffraction (XRD), using the CheMin instrument. The CheMin (Chemistry and Mineralogy) instrument on the Mars Science Laboratory rover Curiosity uses a CCD detector and a Co-anode tube source to acquire both mineralogy (from the pat-tern of Co diffraction) and chemical information (from energies of fluoresced X-rays). A detailed description of CheMin is provided in [1]. As part of the rover checkout after landing, the first sample selected for analysis was an eolian sand deposit (the Rocknest "sand shadow"). This sample was selected in part to characterize unconsolidated eolian regolith, but primarily to prove performance of the scoop collection system on the rover. The focus of the mission after Rocknest was on the consolidated sediments of Gale crater, so all of the nine subsequent samples were collected by drilling into bedrock com-posed of lithified sedimentary materials, including mudstone and sandstone. No scoop samples have been collected since Rocknest, but at the time this abstract was written the mission stands poised to use the scoop again, to collect active dune sands from the Bagnold dune field. Several abstracts at this conference outline the Bagnold dune campaign and summarize preliminary results from analyses on approach to the Namib dune sampling site. In this abstract we review the mineralogy of Rocknest, contrast that with the mineralogy of local sediments, and anticipate what will be learned by XRD analysis of Bagnold dune sands.

  18. Urinary excretion of radionuclides from Marshallese exposed to fallout from the 1954 Bravo nuclear test.

    PubMed

    Harris, Payne S; Simon, Steven L; Ibrahim, Shawki A

    2010-08-01

    Soon after the Bravo nuclear test at Bikini Atoll in the Marshall Islands on 1 March 1954, urine samples were collected for analysis of excreted radioactivity from native residents exposed to radioactive fallout on two atolls as well as from U.S. military personnel on a third atoll. The earliest acquired samples, obtained by the Los Alamos Scientific Laboratory (LASL), were assayed for various radionuclides and provided the first known measurements of (131)I in urine following exposure to fallout from a nuclear test. Over the course of 1954, many additional samples were collected by the LASL, as well as by the Atomic Energy Commission New York Operations Office's Health and Safety Laboratory and the Naval Radiological Defense Laboratory. Collectively, the groups sampled included Marshallese exposed on Rongelap and Ailinginae Atolls, American military weather observers temporarily resident on Rongerik Atoll, and sailors from the Japanese fishing vessel, the Lucky Dragon. While the bioassay measurement data and individual urine volumes have been crucial to various attempts to assess intakes of radioactivity and the related internal radiation doses among the Marshallese, those data have never been published in any peer-reviewed journal, but have been restricted to agency memoranda, laboratory reports, and summaries in some publications and book chapters. Reconstructions of internal doses to Marshallese in 1954 and in later years have depended on these data and, hence, they have considerable historical importance as well as importance to ongoing health risk projections for Marshallese. This paper presents much of the original data on urine volumes and radioactivity from the various assays of urine for radionuclides, and compares estimates of (131)I intakes made in 1954, 1985, 1987, and 2008.

  19. URINARY EXCRETION OF RADIONUCLIDES FROM MARSHALLESE EXPOSED TO FALLOUT FROM THE 1954 BRAVO NUCLEAR TEST

    PubMed Central

    Harris, Payne S.; Simon, Steven L.; Ibrahim, Shawki A.

    2014-01-01

    Soon after the Bravo nuclear test at Bikini Atoll in the Marshall Islands on 1 March 1954, urine samples were collected for analysis of excreted radioactivity from native residents exposed to radioactive fallout on two atolls as well as from U.S. military personnel on a third atoll. The earliest acquired samples, obtained by the Los Alamos Scientific Laboratory (LASL), were assayed for various radionuclides and provided the first known measurements of 131I in urine following exposure to fallout from a nuclear test. Over the course of 1954, many additional samples were collected by the LASL, as well as by the Atomic Energy Commission New York Operations Office’s Health and Safety Laboratory and the Naval Radiological Defense Laboratory. Collectively, the groups sampled included Marshallese exposed on Rongelap and Ailinginae Atolls, American military weather observers temporarily resident on Rongerik Atoll, and sailors from the Japanese fishing vessel, the Lucky Dragon. While the bioassay measurement data and individual urine volumes have been crucial to various attempts to assess intakes of radioactivity and the related internal radiation doses among the Marshallese, those data have never been published in any peer-reviewed journal, but have been restricted to agency memoranda, laboratory reports, and summaries in some publications and book chapters. Reconstructions of internal doses to Marshallese in 1954 and in later years have depended on these data and, hence, they have considerable historical importance as well as importance to ongoing health risk projections for Marshallese. This paper presents much of the original data on urine volumes and radioactivity from the various assays of urine for radionuclides, and compares estimates of 131I intakes made in 1954, 1985, 1987, and 2008. PMID:20622553

  20. Purgeable organic compounds at or near the Idaho Nuclear Technology and Engineering Center, Idaho National Laboratory, Idaho, 2015

    USGS Publications Warehouse

    Maimer, Neil V.; Bartholomay, Roy C.

    2016-05-25

    During 2015, the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, collected groundwater samples from 31 wells at or near the Idaho Nuclear Technology and Engineering Center (INTEC) at the Idaho National Laboratory for purgeable organic compounds (POCs). The samples were collected and analyzed for the purpose of evaluating whether purge water from wells located inside an areal polygon established downgradient of the INTEC must be treated as a Resource Conservation and Recovery Act listed waste.POC concentrations in water samples from 29 of 31 wells completed in the eastern Snake River Plain aquifer were greater than their detection limit, determined from detection and quantitation calculation software, for at least one to four POCs. Of the 29 wells with concentrations greater than their detection limits, only 20 had concentrations greater than the laboratory reporting limit as calculated with detection and quantitation calculation software. None of the concentrations exceeded any maximum contaminant levels established for public drinking water supplies. Most commonly detected compounds were 1,1,1-trichoroethane, 1,1-dichloroethene, and trichloroethene.

  1. Collecting sexual assault history and forensic evidence from adult women in the emergency department: a retrospective study.

    PubMed

    Tozzo, Pamela; Ponzano, Elena; Spigarolo, Gloria; Nespeca, Patrizia; Caenazzo, Luciana

    2018-05-29

    The objective of this retrospective study was to examine the discrepancy between information derived from written medical reports and the results of forensic DNA analyses on swabs collected from the victims in 122 cases of alleged sexual assault treated at the Emergency Department of Padua Hospital. The examination of discrepant results has proved useful to support a broader application of sexual assault management, particularly during the taking of case history. The Laboratory of Forensic Genetics of Padua University have processed samples from 122 sexual assault cases over a period of 5 years. Of the 103 cases in which the victim reported a penetration and ejaculation, only 67 (55% of all the samples) correlated with positive feedback match from the laboratory. In 36 cases in which the patient reported penetration with ejaculation, no male DNA was found in the samples collected. Therefore, there was a total of 41 cases in which the patient's report were not supported by laboratory data. In the remaining ten cases, which had an ambiguous history, 3 tested positively for the presence of male DNA. To avoid discrepancies between the medical reporting and reconstruction of sex crimes, it is crucial to deploy strategies which focus not only on the technical aspects of evidence collection, but also on how the victim's story is recorded; such efforts could lead to better management of sexual assault victims, and to a strengthened legal impact of forensic evidence and of crime reconstruction.

  2. LUNAR SAMPLES - APOLLO XI

    NASA Image and Video Library

    1969-07-27

    S69-45002 (26 July 1969) --- A close-up view of the lunar rocks contained in the first Apollo 11 sample return container. The rock box was opened for the first time in the Vacuum Laboratory of the Manned Spacecraft Center’s Lunar Receiving Laboratory, Building 37, at 3:55 p.m. (CDT), Saturday, July 26, 1969. The gloved hand gives an indication of size. This box also contained the Solar Wind Composition experiment (not shown) and two core tubes for subsurface samples (not shown). These lunar samples were collected by astronauts Neil A. Armstrong and Edwin E. Aldrin Jr. during their lunar surface extravehicular activity on July 20, 1969.

  3. A cryopreservation method for Pasteurella multocida from wetland samples

    USGS Publications Warehouse

    Moore, Melody K.; Shadduck, D.J.; Goldberg, Diana R.; Samuel, M.D.

    1998-01-01

    A cryopreservation method and improved isolation techniques for detection of Pasteurella multocida from wetland samples were developed. Wetland water samples were collected in the field, diluted in dimethyl sulfoxide (DMSO, final concentration 10%), and frozen at -180 C in a liquid nitrogen vapor shipper. Frozen samples were transported to the laboratory where they were subsequently thawed and processed in Pasteurella multocida selective broth (PMSB) to isolate P. multocida. This method allowed for consistent isolation of 2 to 18 organisms/ml from water seeded with known concentrations of P. multocida. The method compared favorably with the standard mouse inoculation method and allowed for preservation of the samples until they could be processed in the laboratory.

  4. Evaluation of chemical data from selected sites in the Surface-Water Ambient Monitoring Program (SWAMP) in Florida

    USGS Publications Warehouse

    Katz, B.G.; Collins, J.J.

    1998-01-01

    A cooperative study between the Florida Department of Environmental Protection (FDEP) and the U.S. Geological Survey was conducted to assess the integrity of selected water-quality data collected at 150 sites in the FDEP Surface-Water Ambient Monitoring Program (SWAMP) in Florida. The assessment included determining the consistency of the water-quality data collected statewide, including commonality of monitoring procedures and analytes, screening of the gross validity of a chemical analysis, and quality assurance and quality control (QA/QC) procedures. Four tests were used to screen data at selected SWAMP sites to estimate the gross validity of selected chemical data: (1) the ratio of dissolved solids (in milligrams per liter) to specific conductance (in microsiemens per centimeter); (2) the ratio of total cations (in milliequivalents per liter) multiplied by 100 to specific conductance (in microsiemens per centimeter); (3) the ratio of total anions (in milliequivalents per liter) multiplied by 100 to specific conductance (in microsiemens per centimeter); and (4) the ionic charge-balance error. Although the results of the four screening tests indicate that the chemical data generally are quite reliable, the extremely small number of samples (less than 5 percent of the total number of samples) with sufficient chemical information to run the tests may not provide a representative indication of the analytical accuracy of all laboratories in the program. In addition to the four screening tests, unusually low or high values were flagged for field and laboratory pH (less than 4.0 and greater than 9.0) and specific conductance (less than 10 and greater than 10,000 microsiemens per centimeter). The numbers of flagged data were less than 1 percent of the 19,937 water samples with pH values and less than 0.6 percent of the 16,553 water samples with specific conductance values. Thirty-four agencies responded to a detailed questionnaire that was sent to more than 60 agencies involved in the collection and analysis of surface-water-quality data for SWAMP. The purpose of the survey was to evaluate quality assurance methods and consistency of methods statewide. Information was compiled and summarized on monitoring network design, data review and upload procedures, laboratory and field sampling methods, and data practices. Currently, most agencies that responded to the survey follow FDEP-approved QA/QC protocol for sampling and have quality assurance practices for recording and reporting data. Also, most agencies responded that calibration procedures were followed in the laboratory for analysis of data, but no responses were given about the specific procedures. Approximately 50 percent of the respondents indicated that laboratory analysis methods have changed over time. With so many laboratories involved in analyzing samples for SWAMP, it is difficult to compare water quality from one site to another due to different reporting conventions for chemical constituents and different analytical methods over time. Most agencies responded that calibration methods are followed in the field, but no specific details were provided. Grab samples are the most common method of collection. Other data screening procedures are necessary to further evaluate the validity of chemical data collected at SWAMP sites. High variability in the concentration of targeted constituents may signal analytical problems, but more likely changes in concentration are related to hydrologic conditions. This underscores the need for accurate measurements of discharge, lake stage, tidal stage at the time of sampling so that changes in constituent concentrations can be properly evaluated and fluxes (loads) of nutrients or metals, for example, can be calculated and compared over time.

  5. NHEXAS PHASE I ARIZONA STUDY--LIST OF STANDARD OPERATING PROCEDURES

    EPA Science Inventory

    This document lists available protocols and SOPs for the NHEXAS Phase I Arizona study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis, (3) General laboratory procedures, (4) Quality Assurance, (...

  6. Field and laboratory analyses of water from the Columbia aquifer in Eastern Maryland

    USGS Publications Warehouse

    Bachman, L.J.

    1984-01-01

    Field and laboratory analyses of pH, alkalinity, and specific conductance from water samples collected from the Columbia aquifer on the Delmarva Peninsula in eastern Maryland were compared to determine if laboratory analyses could be used for making regional water-quality interpretations. Kruskal-Wallis tests of field and laboratory data indicate that the difference between field and laboratory values is usually not enough to affect the outcome of the statistical tests. Thus, laboratory measurements of these constituents may be adequate for making certain regional water-quality interpretations, although they may result in errors if used for geochemical interpretations.

  7. Field tests of nylon-screen diffusion samplers and pushpoint samplers for detection of metals in sediment pore water, Ashland and Clinton, Massachusetts, 2003

    USGS Publications Warehouse

    Zimmerman, Marc J.; Vroblesky, Don A.; Campo, Kimberly W.; Massey, Andrew J.; Scheible, Walter

    2005-01-01

    Efficient and economical screening methods are needed to detect and to determine the approximate concentrations of potentially toxic trace-element metals in shallow groundwater- discharge areas (pore water) where the metals may pose threats to aquatic organisms; such areas are likely to be near hazardous-waste sites. Pushpoint and nylon-screen diffusion samplers are two complementary options for use in such environments. The pushpoint sampler, a simple well point, is easy to insert manually and to use. Only 1 day is required to collect samples. The nylon-screen diffusion sampler is well suited for use in sediments that do not allow a pump to draw water into a pushpoint sampler. In this study, both types of devices were used in sediments suitable for the use of the pushpoint sampler. Sampling with the nylon-screen diffusion sampler requires at least two site visits: one to deploy the samplers in the sediment, and a second to retrieve the samplers and collect the samples after a predetermined equilibration period. Extensive laboratory quality-control studies, field testing, and laboratory analysis of samples collected at the Nyanza Chemical Waste Dump Superfund site along the Sudbury River in Ashland, Massachusetts, and at a Superfund site-assessment location on Rigby Brook in Clinton, Massachusetts, indicate that these two devices yield comparable results for most metals and should be effective tools for pore-water studies. The nylon-screen diffusion samplers equilibrated within 1-2 days in homogeneous, controlled conditions in the laboratory. Nylon-screen diffusion samplers that were not purged of dissolved oxygen prior to deployment yielded results similar to those that were purged. Further testing of the nylon-screen diffusion samplers in homogeneous media would help to resolve any ambiguities about the data variability from the field studies. Comparison of data from replicate samples taken in both study areas shows that even samples taken from sites within a half-meter radius of one another have distinct differences in pore-water trace-element concentrations. Sequential replicate samples collected with the pushpoint sampler yield consistent results; moving the pushpoint sampler even 5 to 10 centimeters, however, generally produces a second set of data that differs enough from the first set of data to indicate a heterogeneous environment. High concentration biases for barium and zinc in laboratory and field samples collected with nylon-screen diffusion samplers, however, may make their use inappropriate for studies of these metals. Analyzing samples with high iron concentrations required sample dilution by factors of 2 or 10. Because these dilutions caused increases in the reporting levels by the same proportion, a substantial fraction of the data was censored. The results from undiluted samples, however, indicate that both devices should be useful for sampling ground water with metal concentrations close to reporting limits.

  8. Fallon, Nevada FORGE Fluid Geochemistry

    DOE Data Explorer

    Blankenship, Doug; Ayling, Bridget

    2018-03-13

    Fluid geochemistry analysis for wells supporting the Fallon FORGE project. Samples were collected from geothermal wells using standard geothermal water sampling techniques, including filtration and acidification of the cation sample to pH < 2 prior to geochemical analysis. Analyses after 2005 were done in reputable commercial laboratories that follow standard protocols for aqueous chemistry analysis.

  9. Sample Integrity Evaluation and EPA Method 325b Interlaboratory Comparison for Select Volatile Organic Compounds Collected Diffusively on Carbopack X Sorbent Tubes

    EPA Science Inventory

    Sample integrity evaluations and inter-laboratory comparisons were conducted in application of U.S. Environmental Protection Agency (EPA) Methods 325A/B for monitoring benzene and additional selected volatile organic compounds (VOCs) usingpassive-diffusive Carbopack X tube sample...

  10. Blood venous sample collection: Recommendations overview and a checklist to improve quality.

    PubMed

    Giavarina, Davide; Lippi, Giuseppe

    2017-07-01

    The extra-analytical phases of the total testing process have substantial impact on managed care, as well as an inherent high risk of vulnerability to errors which is often greater than that of the analytical phase. The collection of biological samples is a crucial preanalytical activity. Problems or errors occurring shortly before, or soon after, this preanalytical step may impair sample quality and characteristics, or else modify the final results of testing. The standardization of fasting requirements, rest, patient position and psychological state of the patient are therefore crucial for mitigating the impact of preanalytical variability. Moreover, the quality of materials used for collecting specimens, along with their compatibility, can guarantee sample quality and persistence of chemical and physical characteristics of the analytes over time, so safeguarding the reliability of testing. Appropriate techniques and sampling procedures are effective to prevent problems such as hemolysis, undue clotting in the blood tube, draw of insufficient sample volume and modification of analyte concentration. An accurate identification of both patient and blood samples is a key priority as for other healthcare activities. Good laboratory practice and appropriate training of operators, by specifically targeting collection of biological samples, blood in particular, may greatly improve this issue, thus lowering the risk of errors and their adverse clinical consequences. The implementation of a simple and rapid check-list, including verification of blood collection devices, patient preparation and sampling techniques, was found to be effective for enhancing sample quality and reducing some preanalytical errors associated with these procedures. The use of this tool, along with implementation of objective and standardized systems for detecting non-conformities related to unsuitable samples, can be helpful for standardizing preanalytical activities and improving the quality of laboratory diagnostics, ultimately helping to reaffirm a "preanalytical" culture founded on knowledge and real risk perception. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  11. Biosafety and containment plan & design for direct sampling of operating effluent decontamination tanks

    USDA-ARS?s Scientific Manuscript database

    Currently, Southeast Poultry Research Laboratory (SEPRL) uses an effluent decontamination system (EDS) that serves as an enhancement, or extra barrier for biocontainment. Wastewater effluent from (A)BSL-3E and (A)BSL-2E laboratories is collected in tanks for thermal inactivation (180°F for 30 minut...

  12. 9 CFR 327.12 - Foreign canned or packaged products bearing trade labels; sampling and inspection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE AGENCY ORGANIZATION AND TERMINOLOGY; MANDATORY... approved under § 317.3 of this subchapter shall be collected and forwarded to the laboratory by the Program inspector for examination, and the products shall be held pending receipt of the report of the laboratory...

  13. Virological Surveillance of Dengue in Saint Martin and Saint Barthélemy, French West Indies, Using Blood Samples on Filter Paper

    PubMed Central

    Matheus, Séverine; Chappert, Jean-Loup; Cassadou, Sylvie; Berger, Franck; Labeau, Bhetty; Bremand, Laetitia; Winicki, Alain; Huc-Anais, Patricia; Quenel, Philippe; Dussart, Philippe

    2012-01-01

    To strengthen active dengue surveillance in Saint Martin and Saint Barthélemy, two French Caribbean islands, we evaluated the epidemiological usefulness of collecting blood samples from NS1-positive dengue patients on filter paper to identify the dengue serotypes circulating in these regions during a 27-month period. This approach allowed dengue serotypes to be identified by reverse transcriptase-polymerase chain reaction in 90.1% of the total set of 666 samples analyzed and, in 95.5% of the samples collected during the acute phase of the disease. This prospective virological surveillance using blood samples absorbed onto filter paper, which were stored at 4°C and shipped at ambient temperature to a specialized laboratory for analysis, allowed us to avoid the logistic and financial costs associated with shipping frozen venous blood samples. This surveillance system offers a low-cost alternative for reinforcing dengue prevention in areas where specialized laboratories do not exist, notably by facilitating the early detection of potentially new dengue serotypes. PMID:22232467

  14. Western blotting method (TESAcruzi) as a supplemental test for confirming the presence of anti-Trypanosoma cruzi antibodies in finger prick blood samples from children aged 0-5 years in Brazil.

    PubMed

    Frade, Amanda Farage; Luquetti, Alejandro O; Prata, Aluísio; Ferreira, Antonio Walter

    2011-01-01

    Some Latin American countries have plans for total control and/or eradication of Chagas disease by the main vector (Triatoma infestans) and by blood transfusion. To achieve this, patients with Chagas disease must be identified. A Western blotting test, TESAcruzi, is described as a supplemental test for diagnosis of Chagas disease using samples collected from children <5 years living in different states of Brazil. Blood samples collected by finger prick on filter paper were sent to the test laboratory by a central laboratory to confirm results obtained previously. Ten percent of negative samples, all doubtful and all positive samples were received. Commercial reagents, IgG indirect immunofluorescence, enzyme immunoassay, and a recently introduced TESAcruzi test were used. From 8788 samples, 163 (1.85%) were reactive by IgG-ELISA and 312 (3.55%) by IgG IIF. From these, 77 (0.87%) were reactive in the TESAcruzi test. The results had high clinical value to identify those truly infected. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Collection and processing of plant, animal and soil samples from Bikini, Enewetak and Rongelap Atolls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stuart, M.L.

    1995-09-01

    The United States used the Marshall Islands for its nuclear weapons program testing site from 1946 to 1958. The BRAVO test was detonated at Bikini Atoll on March 1, 1954. Due to shifting wind conditions at the time of the nuclear detonation, many of the surrounding Atolls became contaminated with fallout (radionuclides carried by the wind currents). Lawrence Livermore National Laboratory`s (LLNL) Marshall Islands Project has been responsible for the collecting, processing, and analyzing of food crops, vegetation, soil, water, animals, and marine species to characterize the radionuclides in the environment, and to estimate dose at atolls that may havemore » been contaminated. Tropical agriculture experiments reducing the uptake of {sup 137}Cs have been conducted on Bikini Atoll. The Marshall Islands field team and laboratory processing team play an important role in the overall scheme of the Marshall Islands Dose Assessment and Radioecology Project. This report gives a general description of the Marshall Islands field sampling and laboratory processing procedures currently used by our staff.« less

  16. [Quality Management System in Pathological Laboratory].

    PubMed

    Koyatsu, Junichi; Ueda, Yoshihiko

    2015-07-01

    Even compared to other clinical laboratories, the pathological laboratory conducts troublesome work, and many of the work processes are also manual. Therefore, the introduction of the systematic management of administration is necessary. It will be a shortcut to use existing standards such as ISO 15189 for this purpose. There is no standard specialized for the pathological laboratory, but it is considered to be important to a pathological laboratory in particular. 1. Safety nianagement of the personnel and environmental conditions. Comply with laws and regulations concerning the handling of hazardous materials. 2. Pre-examination processes. The laboratory shall have documented procedures for the proper collection and handling of primary samples. Developed and documented criteria for acceptance or rejection of samples are applied. 3. Examination processes. Selection, verification, and validation of the examination procedures. Devise a system that can constantly monitor the traceability of the sample. 4. Post-examination processes. Storage, retention, and disposal of clinical samples. 5. Release of results. When examination results fall within established alert or critical intervals, immediately notify the physicians. The important point is to recognize the needs of the client and be aware that pathological diagnoses are always "the final diagnoses".

  17. Chemicals of emerging concern in water and bottom sediment in the Great Lakes Basin, 2012: collection methods, analytical methods, quality assurance, and study data

    USGS Publications Warehouse

    Lee, Kathy E.; Langer, Susan K.; Menheer, Michael A.; Hansen, Donald S.; Foreman, William T.; Furlong, Edward T.; Jorgenson, Zachary G.; Choy, Steven J.; Moore, Jeremy N.; Banda, JoAnn; Gefell, Daniel J.

    2015-01-01

    During this study, 53 environmental samples, 4 field duplicate samples, and 8 field spike samples of bottom sediment and laboratory matrix-spike samples were analyzed for a wide variety of CECs at the USGS National Water Quality Laboratory using laboratory schedule 5433 for wastewater indicators; research method 6434 for steroid hormones, sterols, and bisphenol A; and research method 9008 for human-use pharmaceuticals and antidepressants. Forty of the 57 chemicals analyzed using laboratory schedule 5433 had detectable concentrations ranging from 1 to 49,000 micrograms per kilogram. Fourteen of the 20 chemicals analyzed using research method 6434 had detectable concentrations ranging from 0.04 to 24,940 nanograms per gram. Ten of the 20 chemicals analyzed using research method 9008 had detectable concentrations ranging from 0.59 to 197.5 micrograms per kilogram. Five of the 11 chemicals analyzed using research method 9008 had detectable concentrations ranging from 1.16 to 25.0 micrograms per kilogram.

  18. QUALITY ASSURANCE PROGRAM FOR WET DEPOSITION SAMPLING AND CHEMICAL ANALYSES FOR THE NATIONAL TRENDS NETWORK.

    USGS Publications Warehouse

    Schroder, LeRoy J.; Malo, Bernard A.; ,

    1985-01-01

    The purpose of the National Trends Network is to delineate the major inorganic constituents in the wet deposition in the United States. The approach chosen to monitor the Nation's wet deposition is to install approximately 150 automatic sampling devices with at least one collector in each state. Samples are collected at one week intervals, removed from collectors, and transported to an analytical laboratory for chemical analysis. The quality assurance program has divided wet deposition monitoring into 5 parts: (1) Sampling site selection, (2) sampling device, (3) sample container, (4) sample handling, and (5) laboratory analysis. Each of these five components is being examined using existing designs or new designs. Each existing or proposed sampling site is visited and a criteria audit is performed.

  19. Prevalence of internal parasites in beef cows in the United States: Results of the National Animal Health Monitoring System's (NAHMS) beef study, 2007-2008.

    PubMed

    Stromberg, Bert E; Gasbarre, Louis C; Ballweber, Lora R; Dargatz, David A; Rodriguez, Judith M; Kopral, Christine A; Zarlenga, Dante S

    2015-10-01

    During the United States Department of Agriculture (USDA) National Animal Health Monitoring System's (NAHMS) 2007-2008 beef study, 567 producers from 24 US States were offered the opportunity to collect fecal samples from weaned beef calves and have them evaluated for the presence of parasite eggs (Phase 1). Participating producers were provided with instructions and materials for sample collection. Up to 20 fresh fecal samples were collected from each of the 99 participating operations. Fresh fecal samples were submitted to one of 3 randomly assigned laboratories for evaluation. Upon arrival at the laboratories, all samples were processed for the enumeration of strongyle, Nematodirus, and Trichuris eggs using the modified Wisconsin technique. The presence or absence of coccidian oocysts and tapeworm eggs was also noted. In submissions where the strongyle eggs per gram exceeded 30, aliquots from 2 to 6 animals were pooled for DNA extraction. Extracted DNA was subjected to genus level polymerase chain reaction (PCR) identification for the presence of Ostertagia, Cooperia, Haemonchus, Oesophagostomum, and Trichostrongylus. In this study, 85.6% of the samples had strongyle type, Nematodirus, and Trichuris eggs. Among the samples evaluated, 91% had Cooperia, 79% Ostertagia, 53% Haemonchus, 38% Oesophagostomum, 18% Nematodirus, 7% Trichuris, and 3% Trichostrongylus. The prevalence of coccidia and tapeworm eggs was 59.9% and 13.7%, respectively.

  20. Prevalence of internal parasites in beef cows in the United States: Results of the National Animal Health Monitoring System’s (NAHMS) beef study, 2007–2008

    PubMed Central

    Stromberg, Bert E.; Gasbarre, Louis C.; Ballweber, Lora R.; Dargatz, David A.; Rodriguez, Judith M.; Kopral, Christine A.; Zarlenga, Dante S.

    2015-01-01

    During the United States Department of Agriculture (USDA) National Animal Health Monitoring System’s (NAHMS) 2007–2008 beef study, 567 producers from 24 US States were offered the opportunity to collect fecal samples from weaned beef calves and have them evaluated for the presence of parasite eggs (Phase 1). Participating producers were provided with instructions and materials for sample collection. Up to 20 fresh fecal samples were collected from each of the 99 participating operations. Fresh fecal samples were submitted to one of 3 randomly assigned laboratories for evaluation. Upon arrival at the laboratories, all samples were processed for the enumeration of strongyle, Nematodirus, and Trichuris eggs using the modified Wisconsin technique. The presence or absence of coccidian oocysts and tapeworm eggs was also noted. In submissions where the strongyle eggs per gram exceeded 30, aliquots from 2 to 6 animals were pooled for DNA extraction. Extracted DNA was subjected to genus level polymerase chain reaction (PCR) identification for the presence of Ostertagia, Cooperia, Haemonchus, Oesophagostomum, and Trichostrongylus. In this study, 85.6% of the samples had strongyle type, Nematodirus, and Trichuris eggs. Among the samples evaluated, 91% had Cooperia, 79% Ostertagia, 53% Haemonchus, 38% Oesophagostomum, 18% Nematodirus, 7% Trichuris, and 3% Trichostrongylus. The prevalence of coccidia and tapeworm eggs was 59.9% and 13.7%, respectively. PMID:26424909

  1. Evaluation of the enterovirus laboratory surveillance system in Denmark, 2010 to 2013.

    PubMed

    Condell, Orla; Midgley, Sofie; Christiansen, Claus Bohn; Chen, Ming; Chen Nielsen, Xiaohui; Ellermann-Eriksen, Svend; Mølvadgaard, Mette; Schønning, Kristian; Vermedal Hoegh, Silje; Andersen, Peter Henrik; Voldstedlund, Marianne; Fischer, Thea Kølsen

    2016-05-05

    The primary aim of the Danish enterovirus (EV) surveillance system is to document absence of poliovirus infection. The conflict in Syria has left many children unvaccinated and movement from areas with polio cases to Europe calls for increased awareness to detect and respond to virus-transmission in a timely manner. We evaluate the national EV laboratory surveillance, to generate recommendations for system strengthening. The system was analysed for completeness of viral typing analysis and clinical information and timeliness of specimen collection, laboratory results and reporting of clinical information. Of 23,720 specimens screened, 2,202 (9.3%) were EV-positive. Submission of cerebrospinal fluid and faecal specimens from primary diagnostic laboratories was 79.5% complete (845/1,063), and varied by laboratory and patient age. EV genotypes were determined in 68.5% (979/1,430) of laboratory-confirmed cases, clinical information was available for 63.1% (903/1,430). Primary diagnostic results were available after a median of 1.4 days, typing results after 17 days, detailed clinical information after 33 days. The large number of samples typed demonstrated continued monitoring of EV-circulation in Denmark. The system could be strengthened by increasing the collection of supplementary faecal specimens, improving communication with primary diagnostic laboratories, adapting the laboratory typing methodology and collecting clinical information with electronic forms.

  2. Designing and implementing sample and data collection for an international genetics study: the Type 1 Diabetes Genetics Consortium (T1DGC).

    PubMed

    Hilner, Joan E; Perdue, Letitia H; Sides, Elizabeth G; Pierce, June J; Wägner, Ana M; Aldrich, Alan; Loth, Amanda; Albret, Lotte; Wagenknecht, Lynne E; Nierras, Concepcion; Akolkar, Beena

    2010-01-01

    The Type 1 Diabetes Genetics Consortium (T1DGC) is an international project whose primary aims are to: (a) discover genes that modify type 1 diabetes risk; and (b) expand upon the existing genetic resources for type 1 diabetes research. The initial goal was to collect 2500 affected sibling pair (ASP) families worldwide. T1DGC was organized into four regional networks (Asia-Pacific, Europe, North America, and the United Kingdom) and a Coordinating Center. A Steering Committee, with representatives from each network, the Coordinating Center, and the funding organizations, was responsible for T1DGC operations. The Coordinating Center, with regional network representatives, developed study documents and data systems. Each network established laboratories for: DNA extraction and cell line production; human leukocyte antigen genotyping; and autoantibody measurement. Samples were tracked from the point of collection, processed at network laboratories and stored for deposit at National Institute for Diabetes and Digestive and Kidney Diseases (NIDDK) Central Repositories. Phenotypic data were collected and entered into the study database maintained by the Coordinating Center. T1DGC achieved its original ASP recruitment goal. In response to research design changes, the T1DGC infrastructure also recruited trios, cases, and controls. Results of genetic analyses have identified many novel regions that affect susceptibility to type 1 diabetes. T1DGC created a resource of data and samples that is accessible to the research community. Participation in T1DGC was declined by some countries due to study requirements for the processing of samples at network laboratories and/or final deposition of samples in NIDDK Central Repositories. Re-contact of participants was not included in informed consent templates, preventing collection of additional samples for functional studies. T1DGC implemented a distributed, regional network structure to reach ASP recruitment targets. The infrastructure proved robust and flexible enough to accommodate additional recruitment. T1DGC has established significant resources that provide a basis for future discovery in the study of type 1 diabetes genetics.

  3. [Poliomyelitis case surveillance data management in Burkina Faso].

    PubMed

    Drabo, Koiné Maxime; Nana, Félicité; Kouassi, Kouassi Lazare; Konfé, Salifou; Hien, Hervé; Saizonou, Jacques; Ouedraogo, Tinoaga Laurent

    2015-01-01

    The global initiative for poliomyelitis eradication can only remain relevant if survey systems are regularly assessed. In order to identify shortcomings and to propose improvement, the data collection and transmission during case investigation were assessed in the Banfora health district in Burkina Faso. The survey targeted six (6) primary health centres, the district laboratory and the national laboratory, all involved in the poliomyelitis surveillance system. Data from registers, forms documenting suspected cases, stool sample forms and weekly reports were collected by means of a data grid. Data from actors involved in the poliomyelitis case investigation system were collected by means of an individual questionnaire. The reactivity of investigating suspected cases was satisfactory with a median alert questionnaire notification time of 18 hours. The completeness of the reporting system was satisfactory. Nevertheless, the promptness of data management by primary heath centres and the national laboratory remained unsatisfactory. Evaluation of data management revealed logistic and organization shortcomings. The overall efficacy of the poliomyelitis surveillance could be improved by using management tools for laboratory supplies, collecting data related to the homes of suspected cases and implementing a cold chain maintenance plan.

  4. Colour coding for blood collection tube closures - a call for harmonisation.

    PubMed

    Simundic, Ana-Maria; Cornes, Michael P; Grankvist, Kjell; Lippi, Giuseppe; Nybo, Mads; Ceriotti, Ferruccio; Theodorsson, Elvar; Panteghini, Mauro

    2015-02-01

    At least one in 10 patients experience adverse events while receiving hospital care. Many of the errors are related to laboratory diagnostics. Efforts to reduce laboratory errors over recent decades have primarily focused on the measurement process while pre- and post-analytical errors including errors in sampling, reporting and decision-making have received much less attention. Proper sampling and additives to the samples are essential. Tubes and additives are identified not only in writing on the tubes but also by the colour of the tube closures. Unfortunately these colours have not been standardised, running the risk of error when tubes from one manufacturer are replaced by the tubes from another manufacturer that use different colour coding. EFLM therefore supports the worldwide harmonisation of the colour coding for blood collection tube closures and labels in order to reduce the risk of pre-analytical errors and improve the patient safety.

  5. 2013 Annual Wastewater Reuse Report for the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mike Lewis

    2014-02-01

    This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (#LA-000141-03), for the wastewater land application site at the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant from November 1, 2012, through October 31, 2013. The report contains, as applicable, the following information: • Site description • Facility and system description • Permit required monitoring data and loading rates • Status of compliance conditions and activities • Discussion of the facility’s environmental impacts. During the 2013 permit year, no wastewater was land-applied to the irrigation area of the Central Facilities Area Sewage Treatment Plantmore » and therefore, no effluent flow volumes or samples were collected from wastewater sampling point WW-014102. However, soil samples were collected in October from soil monitoring unit SU-014101.« less

  6. Laboratory procedures to generate viral metagenomes.

    PubMed

    Thurber, Rebecca V; Haynes, Matthew; Breitbart, Mya; Wegley, Linda; Rohwer, Forest

    2009-01-01

    This collection of laboratory protocols describes the steps to collect viruses from various samples with the specific aim of generating viral metagenome sequence libraries (viromes). Viral metagenomics, the study of uncultured viral nucleic acid sequences from different biomes, relies on several concentration, purification, extraction, sequencing and heuristic bioinformatic methods. No single technique can provide an all-inclusive approach, and therefore the protocols presented here will be discussed in terms of hypothetical projects. However, care must be taken to individualize each step depending on the source and type of viral-particles. This protocol is a description of the processes we have successfully used to: (i) concentrate viral particles from various types of samples, (ii) eliminate contaminating cells and free nucleic acids and (iii) extract, amplify and purify viral nucleic acids. Overall, a sample can be processed to isolate viral nucleic acids suitable for high-throughput sequencing in approximately 1 week.

  7. Formation and retention of methane in coal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hucka, V.J.; Bodily, D.M.; Huang, H.

    1992-05-15

    The formation and retention of methane in coalbeds was studied for ten Utah coal samples, one Colorado coal sample and eight coal samples from the Argonne Premium Coal Sample Bank.Methane gas content of the Utah and Colorado coals varied from zero to 9 cm{sup 3}/g. The Utah coals were all high volatile bituminous coals. The Colorado coal was a gassy medium volatile bituminous coal. The Argonne coals cover a range or rank from lignite to low volatile bituminous coal and were used to determine the effect of rank in laboratory studies. The methane content of six selected Utah coal seamsmore » and the Colorado coal seam was measured in situ using a special sample collection device and a bubble desorbometer. Coal samples were collected at each measurement site for laboratory analysis. The cleat and joint system was evaluated for the coal and surrounding rocks and geological conditions were noted. Permeability measurements were performed on selected samples and all samples were analyzed for proximate and ultimate analysis, petrographic analysis, {sup 13}C NMR dipolar-dephasing spectroscopy, and density analysis. The observed methane adsorption behavior was correlated with the chemical structure and physical properties of the coals.« less

  8. Formation and retention of methane in coal. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hucka, V.J.; Bodily, D.M.; Huang, H.

    1992-05-15

    The formation and retention of methane in coalbeds was studied for ten Utah coal samples, one Colorado coal sample and eight coal samples from the Argonne Premium Coal Sample Bank.Methane gas content of the Utah and Colorado coals varied from zero to 9 cm{sup 3}/g. The Utah coals were all high volatile bituminous coals. The Colorado coal was a gassy medium volatile bituminous coal. The Argonne coals cover a range or rank from lignite to low volatile bituminous coal and were used to determine the effect of rank in laboratory studies. The methane content of six selected Utah coal seamsmore » and the Colorado coal seam was measured in situ using a special sample collection device and a bubble desorbometer. Coal samples were collected at each measurement site for laboratory analysis. The cleat and joint system was evaluated for the coal and surrounding rocks and geological conditions were noted. Permeability measurements were performed on selected samples and all samples were analyzed for proximate and ultimate analysis, petrographic analysis, {sup 13}C NMR dipolar-dephasing spectroscopy, and density analysis. The observed methane adsorption behavior was correlated with the chemical structure and physical properties of the coals.« less

  9. NHEXAS PHASE I MARYLAND STUDY--LIST OF AVAILABLE DOCUMENTS: PROTOCOLS AND SOPS

    EPA Science Inventory

    This document lists available protocols and SOPs for the NHEXAS Phase I Maryland study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis and general laboratory procedures, (3) Data Analysis Proced...

  10. Chamber study of PCBemissions from caulking materials and light ballasts

    EPA Science Inventory

    The emissions of polychlorinated biphenyl (PCB) congeners from 13 caulk samples were tested in a micro-chamber system. Twelve samples were from PCB-contaminated buildings and one was prepared in the laboratory. Nineteen light ballasts collected from buildings that represent 13 di...

  11. Mercury accumulation in snow on the Idaho National Engineering and Environmental Laboratory and surrounding region, southeast Idaho, USA

    USGS Publications Warehouse

    Susong, D.D.; Abbott, M.L.; Krabbenhoft, D.P.

    2003-01-01

    Snow was sampled and analyzed for total mercury (THg) on the Idaho National Engineering and Environmental Laboratory (INEEL) and surrounding region prior to the start-up of a large (9-11 g/h) gaseous mercury emission source. The objective was to determine the effects of the source on local and regional atmospheric deposition of mercury. Snow samples collected from 48 points on a polar grid near the source had THg concentrations that ranged from 4.71 to 27.26 ng/L; snow collected from regional background sites had THg concentrations that ranged from 0.89 to 16.61 ng/L. Grid samples had higher concentrations than the regional background sites, which was unexpected because the source was not operating yet. Emission of Hg from soils is a possible source of Hg in snow on the INEEL. Evidence from Hg profiles in snow and from unfiltered/filtered split samples supports this hypothesis. Ongoing work on the INEEL is investigating Hg fluxes from soils and snow.

  12. Radiochemical and Chemical Constituents in Water from Selected Wells and Springs from the Southern Boundary of the Idaho National Engineering and Environmental Laboratory to the Hagerman Area, Idaho, 1998

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. C. Bartholomay; B. V. Twining; L. J. Campbell

    1999-06-01

    The U.S. Geological Survey and the Idaho Department of Water Resources, in cooperation with the U.S. Department of Energy, sampled 18 sites as part of the fourth round of a long-term project to monitor water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering and Environmental Laboratory to the Hagerman area. The samples were analyzed for selected radiochemical and chemical constituents. The samples were collected from 2 domestic wells, 12 irrigation wells, 2 stock wells, 1 spring, and 1 public supply well. Two quality-assurance samples also were collected and analyzed. None of themore » reported radiochemical or chemical constituent concentrations exceeded the established maximum contaminant levels for drinking water. Many of the radionuclide- and inorganic-constituent concentrations were greater than the respective reporting levels. Most of the organic-constituent concentrations were less than the reporting levels.« less

  13. Field guide for collecting samples for analysis of volatile organic compounds in stream water for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.

    1997-01-01

    For many years, stream samples for analysis of volatile organic compounds have been collected without specific guidelines or a sampler designed to avoid analyte loss. In 1996, the U.S. Geological Survey's National Water-Quality Assessment Program began aggressively monitoring urban stream-water for volatile organic compounds. To assure representative samples and consistency in collection procedures, a specific sampler was designed to collect samples for analysis of volatile organic compounds in stream water. This sampler, and the collection procedures, were tested in the laboratory and in the field for compound loss, contamination, sample reproducibility, and functional capabilities. This report describes that sampler and its use, and outlines field procedures specifically designed to provide contaminant-free, reproducible volatile organic compound data from stream-water samples. These guidelines and the equipment described represent a significant change in U.S. Geological Survey instructions for collecting and processing stream-water samples for analysis of volatile organic compounds. They are intended to produce data that are both defensible and interpretable, particularly for concentrations below the microgram-per-liter level. The guidelines also contain detailed recommendations for quality-control samples.

  14. Integrated Data Collection Analysis (IDCA) Program - RDX Type II Class 5 Standard, Data Set 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.

    This document describes the results of the first reference sample material—RDX Type II Class 5—examined in the proficiency study for small-scale safety and thermal (SSST) testing of explosive materials for the Integrated Data Collection Analysis (IDCA) Program. The IDCA program is conducting proficiency testing on homemade explosives (HMEs). The reference sample materials are being studied to establish the accuracy of traditional explosives safety testing for each performing laboratory. These results will be used for comparison to results from testing HMEs. This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of thesemore » materials in perspective with standard military explosives. The results of the study will add SSST testing results for a broad suite of different HMEs to the literature, potentially suggest new guidelines and methods for HME testing, and possibly establish what are the needed accuracies in SSST testing to develop safe handling practices. Described here are the results for impact, friction, electrostatic discharge, and scanning calorimetry analysis of a reference sample of RDX Type II Class 5. The results from each participating testing laboratory are compared using identical test material and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. These results are then compared to historical data from various sources. The performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Air Force Research Laboratory/ RXQL (AFRL), Indian Head Division, Naval Surface Warfare Center, (IHD-NSWC), and Sandia National Laboratories (SNL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when test protocols are not identical.« less

  15. Sodium and potassium content of 24 h urinary collections: a comparison between field- and laboratory-based analysers.

    PubMed

    Yin, Xuejun; Neal, Bruce; Tian, Maoyi; Li, Zhifang; Petersen, Kristina; Komatsu, Yuichiro; Feng, Xiangxian; Wu, Yangfeng

    2018-04-01

    Measurement of mean population Na and K intakes typically uses laboratory-based assays, which can add significant logistical burden and costs. A valid field-based measurement method would be a significant advance. In the current study, we used 24 h urine samples to compare estimates of Na, K and Na:K ratio based upon assays done using the field-based Horiba twin meter v. laboratory-based methods. The performance of the Horiba twin meter was determined by comparing field-based estimates of mean Na and K against those obtained using laboratory-based methods. The reported 95 % limits of agreement of Bland-Altman plots were calculated based on a regression approach for non-uniform differences. The 24 h urine samples were collected as part of an ongoing study being done in rural China. One hundred and sixty-six complete 24 h urine samples were qualified for estimating 24 h urinary Na and K excretion. Mean Na and K excretion were estimated as 170·4 and 37·4 mmol/d, respectively, using the meter-based assays; and 193·4 and 43·8 mmol/d, respectively, using the laboratory-based assays. There was excellent relative reliability (intraclass correlation coefficient) for both Na (0·986) and K (0·986). Bland-Altman plots showed moderate-to-good agreement between the two methods. Na and K intake estimations were moderately underestimated using assays based upon the Horiba twin meter. Compared with standard laboratory-based methods, the portable device was more practical and convenient.

  16. Chemistry Data for Geothermometry Mapping of Deep Hydrothermal Reservoirs in Southeastern Idaho

    DOE Data Explorer

    Earl Mattson

    2016-01-18

    This dataset includes chemistry of geothermal water samples of the Eastern Snake River Plain and surrounding area. The samples included in this dataset were collected during the springs and summers of 2014 and 2015. All chemical analysis of the samples were conducted in the Analytical Laboratory at the Center of Advanced Energy Studies in Idaho Falls, Idaho. This data set supersedes #425 submission and is the final submission for AOP 3.1.2.1 for INL. Isotopic data collected by Mark Conrad will be submitted in a separate file.

  17. Faster, better, cheaper: lean labs are the key to future survival.

    PubMed

    Bryant, Patsy M; Gulling, Richard D

    2006-03-28

    Process improvement techniques have been used in manufacturing for many years to rein in costs and improve quality. Health care is now grappling with similar challenges. The Department of Laboratory Services at Good Samaritan Hospital, a 560-bed facility in Dayton, OH, used the Lean process improvement method in a 12-week project to streamline its core laboratory processes. By analyzing the flow of samples through the system and identifying value-added and non-value-added steps, both in the laboratory and during the collection process, Good Samaritan's project team redesigned systems and reconfigured the core laboratory layout to trim collection-to-results time from 65 minutes to 40 minutes. As a result, virtually all morning results are available to physicians by 7 a.m., critical values are called to nursing units within 30 minutes, and core laboratory services are optimally staffed for maximum cost-effectiveness.

  18. Whole Air Sampling During NASA's March-April 1999 Pacific Exploratory Expedition (PEM-Tropics B)

    NASA Technical Reports Server (NTRS)

    Blake, Donald R.

    2001-01-01

    University of California, Irvine (UCI) collected more than 4500 samples whole air samples collected over the remote Pacific Ocean during NASA's Global Tropospheric Experiment (GTE) Pacific Exploratory Mission-Tropics B (PEM-Tropics B) in March and early April 1999. Approximately 140 samples during a typical 8-hour DC-8 flight, and 120 canisters for each 8-hour flight aboard the P-3B. These samples were obtained roughly every 3-7 min during horizontal flight legs and 1-3 min during vertical legs. The filled canisters were analyzed in the laboratory at UCI within ten days of collection. The mixing ratios of 58 trace gases comprising hydrocarbons, halocarbons, alkyl nitrates and DMS were reported (and archived) for each sample. Two identical analytical systems sharing the same standards were operated simultaneously around the clock to improve canister turn-around time and to keep our measurement precision optimal. This report presents a summary of the results for sample collected.

  19. Specimen rejection in laboratory medicine: Necessary for patient safety?

    PubMed

    Dikmen, Zeliha Gunnur; Pinar, Asli; Akbiyik, Filiz

    2015-01-01

    The emergency laboratory in Hacettepe University Hospitals receives specimens from emergency departments (EDs), inpatient services and intensive care units (ICUs). The samples are accepted according to the rejection criteria of the laboratory. In this study, we aimed to evaluate the sample rejection ratios according to the types of pre-preanalytical errors and collection areas. The samples sent to the emergency laboratory were recorded during 12 months between January to December, 2013 in which 453,171 samples were received and 27,067 specimens were rejected. Rejection ratios was 2.5% for biochemistry tests, 3.2% for complete blood count (CBC), 9.8% for blood gases, 9.2% for urine analysis, 13.3% for coagulation tests, 12.8% for therapeutic drug monitoring, 3.5% for cardiac markers and 12% for hormone tests. The most frequent rejection reasons were fibrin clots (28%) and inadequate volume (9%) for biochemical tests. Clotted samples (35%) and inadequate volume (13%) were the major causes for coagulation tests, blood gas analyses and CBC. The ratio of rejected specimens was higher in the EDs (40%) compared to ICUs (30%) and inpatient services (28%). The highest rejection ratio was observed in neurology ICU (14%) among the ICUs and internal medicine inpatient service (10%) within inpatient clinics. We detected an overall specimen rejection rate of 6% in emergency laboratory. By documentation of rejected samples and periodic training of healthcare personnel, we expect to decrease sample rejection ratios below 2%, improve total quality management of the emergency laboratory and promote patient safety.

  20. Review of Pre-Analytical Errors in Oral Glucose Tolerance Testing in a Tertiary Care Hospital.

    PubMed

    Nanda, Rachita; Patel, Suprava; Sahoo, Sibashish; Mohapatra, Eli

    2018-03-13

    The pre-pre-analytical and pre-analytical phases form a major chunk of the errors in a laboratory. The process has taken into consideration a very common procedure which is the oral glucose tolerance test to identify the pre-pre-analytical errors. Quality indicators provide evidence of quality, support accountability and help in the decision making of laboratory personnel. The aim of this research is to evaluate pre-analytical performance of the oral glucose tolerance test procedure. An observational study that was conducted overa period of three months, in the phlebotomy and accessioning unit of our laboratory using questionnaire that examined the pre-pre-analytical errors through a scoring system. The pre-analytical phase was analyzed for each sample collected as per seven quality indicators. About 25% of the population gave wrong answer with regard to the question that tested the knowledge of patient preparation. The appropriateness of test result QI-1 had the most error. Although QI-5 for sample collection had a low error rate, it is a very important indicator as any wrongly collected sample can alter the test result. Evaluating the pre-analytical and pre-pre-analytical phase is essential and must be conducted routinely on a yearly basis to identify errors and take corrective action and to facilitate their gradual introduction into routine practice.

  1. Hydrologic data collected in and around a surface coal mine, Clay and Vigo counties, Indiana, 1977-80

    USGS Publications Warehouse

    Bobo, Linda L.; Eikenberry, Stephen E.

    1982-01-01

    Few data are available for evaluating water-quality and other hydrologic properties in and around surface coal mines, particularly in areas where material having a high potential for acid-production is selectively buried. This report contains hydrologic data collected in an active coal mining area in Clay and Vigo Counties, Indiana, from September 1977 through February 1980. Methods of sampling and analysis used in collecting the data also are summarized. The data include field and laboratory measurements of water at 41 wells and 24 stream sites. Variables measured in the field include water temperature, specific conductance, pH, Eh, dissolved oxygen, ground-water levels, and streamflow; and in the laboratory, concentrations of major ions, alkalinity, hardness, trace elementsl, organic carbon, phosphorus, and dissolved solids. Other variables measured in the laboratory include ferrous iron concentration of water samples from selected wells, percent sulfur by weight and the potential acidity of core samples of reclaimed cast overburden, concentrations of elements absorbed on streambed materials, concentrations and particle size of suspended sediment in water, and populations and Shannon diversity indices of phytoplankton in water. Dissolved-solids concentrations and pH of ground water ranged from 173 to 5,130 milligrams per liter and from 6.1 to 8.9, respectively, and of surface water, from 120 to 4,100 milligrams per liter and from 6.1 to 8.8 respectively. 

  2. Health-hazard-evaluation report HETA 87-387-2050, Ithaca College, Ithaca, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Almaguer, D.; Klein, M.; Klincewicz, S.

    1990-06-01

    In response to a request from an authorized representative of the employees of Ithaca College located in Ithaca, New York, a study was made of possible hazardous conditions at the college stemming from the use of formalin solutions during the embalming and fixing of primates for study. Samples were collected in the anatomy laboratory, the refrigeration room, and the hallway which separated the two rooms. Analyses of the 22 samples collected ranged from nondetectable to 0.12 parts per million for formaldehyde. Two samples which contained quantifiable levels of formaldehyde were collected in the anatomy laboratory. All tests for phenol andmore » ethylene-glycol showed nondetectable levels. Measurements indicated the ventilation system supplied air to the location in line with requirements but that air distribution and exhaust within the laboratory were not conducive to minimizing occupant exposure to contaminants. Only one set of exhaust conditions was under negative pressure. Ventilation may have been inadequate. The staff reported symptoms of headache, sinus congestion, odors in the office, sore throat, and itching and burning eyes. The authors conclude that exposures to low levels of formaldehyde existed at the time of the survey. Formaldehyde levels measured during the study were not deemed high enough to be causing reported symptoms. The authors recommend measures to improve the ventilation system.« less

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kautsky, Mark; Nguyen, Jason; Darr, Paul S.

    The Long-Term Surveillance and Maintenance Plan (LTSMP) for Amchitka details how the U.S. Department of Energy (DOE) intends to fulfill its mission to maintain protection of human health and the environment at and around the sites on Amchitka Island. The LTSMP calls for monitoring to be performed every 5 years, at least in the initial phase of the project. The purpose of the monitoring is to develop a baseline of activity concentrations for selected radionuclides in biota, water, and soil, both on Amchitka and at the reference location on Adak Island, approximately 322 km (200 miles) northeast of Amchitka. Datamore » compiled by the Consortium for Risk Evaluation with Stakeholder Participation (CRESP, 2006) are being included as part of the baseline data set. The specific biological, water, and sediment samples collected during the 2011 sampling event were developed through close coordination with the primary stakeholders, including the Alaska Department of Environmental Conservation, the Aleutian Pribilof Island Association, and the U.S. Fish and Wildlife Service (USFWS). Amchitka is managed by the USFWS as part of the Alaska Maritime National Wildlife Refuge. Two plans were developed to address specific needs of the biological- and the terrestrial-monitoring programs. Results from these monitoring programs will help determine whether the environment is being impacted by radionuclide migration and uptake, and if subsistence and commercial-catch seafood is safe for human consumption. The RESRAD-BIOTA code is being used to evaluate ecological health relative to the radionuclide levels determined from this sampling event. The samples were sent to three laboratories for analysis. With the exception of the seawater samples, most of the samples were sent to the Center for Accelerator Mass Spectrometry at the Lawrence Livermore National Laboratory. A smaller subset of rock-weed samples, Star reindeer lichen samples, and soil samples collected from beneath the lichen were sent to UAF for cesium-137 analysis. Marine sediment samples were also collected and sent to UAF for testing. The seawater samples were sent to the University of Miami Tritium Laboratory for enriched tritium analysis. Results from the seawater samples for tritium were received in September 2011. Results from the 2011 sampling are expected to be available on the LM web site in 2012. (authors)« less

  4. adLIMS: a customized open source software that allows bridging clinical and basic molecular research studies.

    PubMed

    Calabria, Andrea; Spinozzi, Giulio; Benedicenti, Fabrizio; Tenderini, Erika; Montini, Eugenio

    2015-01-01

    Many biological laboratories that deal with genomic samples are facing the problem of sample tracking, both for pure laboratory management and for efficiency. Our laboratory exploits PCR techniques and Next Generation Sequencing (NGS) methods to perform high-throughput integration site monitoring in different clinical trials and scientific projects. Because of the huge amount of samples that we process every year, which result in hundreds of millions of sequencing reads, we need to standardize data management and tracking systems, building up a scalable and flexible structure with web-based interfaces, which are usually called Laboratory Information Management System (LIMS). We started collecting end-users' requirements, composed of desired functionalities of the system and Graphical User Interfaces (GUI), and then we evaluated available tools that could address our requirements, spanning from pure LIMS to Content Management Systems (CMS) up to enterprise information systems. Our analysis identified ADempiere ERP, an open source Enterprise Resource Planning written in Java J2EE, as the best software that also natively implements some highly desirable technological advances, such as the high usability and modularity that grants high use-case flexibility and software scalability for custom solutions. We extended and customized ADempiere ERP to fulfil LIMS requirements and we developed adLIMS. It has been validated by our end-users verifying functionalities and GUIs through test cases for PCRs samples and pre-sequencing data and it is currently in use in our laboratories. adLIMS implements authorization and authentication policies, allowing multiple users management and roles definition that enables specific permissions, operations and data views to each user. For example, adLIMS allows creating sample sheets from stored data using available exporting operations. This simplicity and process standardization may avoid manual errors and information backtracking, features that are not granted using track recording on files or spreadsheets. adLIMS aims to combine sample tracking and data reporting features with higher accessibility and usability of GUIs, thus allowing time to be saved on doing repetitive laboratory tasks, and reducing errors with respect to manual data collection methods. Moreover, adLIMS implements automated data entry, exploiting sample data multiplexing and parallel/transactional processing. adLIMS is natively extensible to cope with laboratory automation through platform-dependent API interfaces, and could be extended to genomic facilities due to the ERP functionalities.

  5. Software Engineering Laboratory (SEL) Data Base Maintenance System (DBAM) user's guide and system description

    NASA Technical Reports Server (NTRS)

    Lo, P. S.; Card, D.

    1983-01-01

    The Software Engineering Laboratory (SEL) Data Base Maintenance System (DBAM) is explained. The various software facilities of the SEL, DBAM operating procedures, and DBAM system information are described. The relationships among DBAM components (baseline diagrams), component descriptions, overlay descriptions, indirect command file listings, file definitions, and sample data collection forms are provided.

  6. The Histopathologic Reliability of Tissue Taken from Cadavers within the Gross Anatomy Laboratory

    ERIC Educational Resources Information Center

    Rae, Guenevere; Newman, William P., III; McGoey, Robin; Donthamsetty, Supriya; Karpinski, Aryn C.; Green, Jeffrey

    2018-01-01

    The purpose of this study was to examine the histopathologic reliability of embalmed cadaveric tissue taken from the gross anatomy laboratory. Tissue samples from hearts, livers, lungs, and kidneys were collected after the medical students' dissection course was completed. All of the cadavers were embalmed in a formalin-based fixative solution.…

  7. EVALUATION OF DISPOSABLE DIAPERS FOR QUANTATIVE MEASUREMENTS OF PESTICIDE METABOLITES AND CREATININE IN URINE SAMPLES

    EPA Science Inventory

    This project consisted of a laboratory study to evaluate an extraction and analysis method for quantifying biomarkers of pesticide exposure and creatinine in urine samples collected with commercially-available disposable diapers. For large exposure studies, such as the National ...

  8. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--LIST OF STANDARD OPERATING PROCEDURES

    EPA Science Inventory

    This document lists available protocols and SOPs for the U.S.-Mexico Border Program study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis, (3) General laboratory procedures, (4) Quality Assuranc...

  9. USGS/EPA collection protocol for bacterial pathogens in soil

    USGS Publications Warehouse

    Griffin, Dale W.; Shaefer, F.L.; Charlena Bowling,; Dino Mattorano,; Tonya Nichols,; Erin Silvestri,

    2014-01-01

    This Sample Collection Procedure (SCP) describes the activities and considerations for the collection of bacterial pathogens from representative surface soil samples (0-5 cm). This sampling depth can be reached without the use of a drill rig, direct-push technology, or other mechanized equipment. This procedure can be used in most soil types but is limited to sampling at or near the ground surface. This protocol has components for two different types of sampling applications: (1) typical sampling, when there is no suspicion of contamination (e.g., surveillance or background studies); and (2) in response to known or suspected accidental contamination (e.g., the presence of animal carcasses). This protocol does not cover sampling in response to a suspected bioterrorist or intentional release event. Surface material is removed to the required depth (0-5 cm) and clean trowel or 50 ml sample tube is used to collect the sample. Sample containers are sealed, bagged, and shipped to the laboratory for analysis. Associated documentation, including a Field Data Log and Chain-of-Custody are also included in this document.

  10. QA/QC requirements for physical properties sampling and analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Innis, B.E.

    1993-07-21

    This report presents results of an assessment of the available information concerning US Environmental Protection Agency (EPA) quality assurance/quality control (QA/QC) requirements and guidance applicable to sampling, handling, and analyzing physical parameter samples at Comprehensive Environmental Restoration, Compensation, and Liability Act (CERCLA) investigation sites. Geotechnical testing laboratories measure the following physical properties of soil and sediment samples collected during CERCLA remedial investigations (RI) at the Hanford Site: moisture content, grain size by sieve, grain size by hydrometer, specific gravity, bulk density/porosity, saturated hydraulic conductivity, moisture retention, unsaturated hydraulic conductivity, and permeability of rocks by flowing air. Geotechnical testing laboratories alsomore » measure the following chemical parameters of soil and sediment samples collected during Hanford Site CERCLA RI: calcium carbonate and saturated column leach testing. Physical parameter data are used for (1) characterization of vadose and saturated zone geology and hydrogeology, (2) selection of monitoring well screen sizes, (3) to support modeling and analysis of the vadose and saturated zones, and (4) for engineering design. The objectives of this report are to determine the QA/QC levels accepted in the EPA Region 10 for the sampling, handling, and analysis of soil samples for physical parameters during CERCLA RI.« less

  11. Site Environmental Report for 2009, Volume 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Suying

    2010-08-19

    Volume II of the Site Environmental Report for 2009 is provided by Ernest Orlando Lawrence Berkeley National Laboratory as a supplemental appendix to Volume I, which contains the body of the report. Volume II contains the environmental monitoring and sampling data used to generate summary results of routine and nonroutine sampling at the Laboratory, except for groundwater sampling data, which may be found in the reports referred to in Chapter 4 of Volume I. The results from sample collections are more comprehensive in Volume II than in Volume I: for completeness, all results from sample collections that began or endedmore » in calendar year (CY) 2009 are included in this volume. However, the samples representing CY 2008 data have not been used in the summary results that are reported in Volume I. (For example, although ambient air samples collected on January 6, 2009, are presented in Volume II, they represent December 2008 data and are not included in Table 4-2 in Volume I.) When appropriate, sampling results are reported in both conventional and International System (SI) units. For some results, the rounding procedure used in data reporting may result in apparent differences between the numbers reported in SI and conventional units. (For example, stack air tritium results reported as < 1.5 Bq/m3 are shown variously as < 39 and < 41 pCi/m3. Both of these results are rounded correctly to two significant digits.)« less

  12. Genesis Solar Wind Interstream, Coronal Hole and Coronal Mass Ejection Samples: Update on Availability and Condition

    NASA Technical Reports Server (NTRS)

    Allton, J. H.; Gonzalez, C. P.; Allums, K. K.

    2017-01-01

    Recent refinement of analysis of ACE/SWICS data (Advanced Composition Explorer/Solar Wind Ion Composition Spectrometer) and of onboard data for Genesis Discovery Mission of 3 regimes of solar wind at Earth-Sun L1 make it an appropriate time to update the availability and condition of Genesis samples specifically collected in these three regimes and currently curated at Johnson Space Center. ACE/SWICS spacecraft data indicate that solar wind flow types emanating from the interstream regions, from coronal holes and from coronal mass ejections are elementally and isotopically fractionated in different ways from the solar photosphere, and that correction of solar wind values to photosphere values is non-trivial. Returned Genesis solar wind samples captured very different kinds of information about these three regimes than spacecraft data. Samples were collected from 11/30/2001 to 4/1/2004 on the declining phase of solar cycle 23. Meshik, et al is an example of precision attainable. Earlier high precision laboratory analyses of noble gases collected in the interstream, coronal hole and coronal mass ejection regimes speak to degree of fractionation in solar wind formation and models that laboratory data support. The current availability and condition of samples captured on collector plates during interstream slow solar wind, coronal hole high speed solar wind and coronal mass ejections are de-scribed here for potential users of these samples.

  13. Field guide for collecting and processing stream-water samples for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.

    1994-01-01

    The U.S. Geological Survey's National Water-Quality Assessment program includes extensive data- collection efforts to assess the quality of the Nations's streams. These studies require analyses of stream samples for major ions, nutrients, sediments, and organic contaminants. For the information to be comparable among studies in different parts of the Nation, consistent procedures specifically designed to produce uncontaminated samples for trace analysis in the laboratory are critical. This field guide describes the standard procedures for collecting and processing samples for major ions, nutrients, organic contaminants, sediment, and field analyses of conductivity, pH, alkalinity, and dissolved oxygen. Samples are collected and processed using modified and newly designed equipment made of Teflon to avoid contamination, including nonmetallic samplers (D-77 and DH-81) and a Teflon sample splitter. Field solid-phase extraction procedures developed to process samples for organic constituent analyses produce an extracted sample with stabilized compounds for more accurate results. Improvements to standard operational procedures include the use of processing chambers and capsule filtering systems. A modified collecting and processing procedure for organic carbon is designed to avoid contamination from equipment cleaned with methanol. Quality assurance is maintained by strict collecting and processing procedures, replicate sampling, equipment blank samples, and a rigid cleaning procedure using detergent, hydrochloric acid, and methanol.

  14. Technology Development and Advanced Planning for Curation of Returned Mars Samples

    NASA Technical Reports Server (NTRS)

    Lindstrom, David J.; Allen, Carlton C.

    2002-01-01

    NASA Johnson Space Center (JSC) curates extraterrestrial samples, providing the international science community with lunar rock and soil returned by the Apollo astronauts, meteorites collected in Antarctica, cosmic dust collected in the stratosphere, and hardware exposed to the space environment. Curation comprises initial characterization of new samples, preparation and allocation of samples for research, and clean, secure long-term storage. The foundations of this effort are the specialized cleanrooms (class 10 to 10,000) for each of the four types of materials, the supporting facilities, and the people, many of whom have been doing detailed work in clean environments for decades. JSC is also preparing to curate the next generation of extraterrestrial samples. These include samples collected from the solar wind, a comet, and an asteroid. Early planning and R\\&D are underway to support post-mission sample handling and curation of samples returned from Mars. One of the strong scientific reasons for returning samples from Mars is to search for evidence of current or past life in the samples. Because of the remote possibility that the samples may contain life forms that are hazardous to the terrestrial biosphere, the National Research Council has recommended that all samples returned from Mars be kept under strict biological containment until tests show that they can safely be released to other laboratories. It is possible that Mars samples may contain only scarce or subtle traces of life or prebiotic chemistry that could readily be overwhelmed by terrestrial contamination . Thus, the facilities used to contain, process, and analyze samples from Mars must have a combination of high-level biocontainment and organic / inorganic chemical cleanliness that is unprecedented. JSC has been conducting feasibility studies and developing designs for a sample receiving facility that would offer biocontainment at least the equivalent of current maximum containment BSL-4 (BioSafety Level 4) laboratories, while simultaneously maintaining cleanliness levels equaling those of state-of-the-art cleanrooms. Unique requirements for the processing of Mars samples have inspired a program to develop handling techniques that are much more precise and reliable than the approach (currently used for lunar samples) of employing gloved human hands in nitrogen-filled gloveboxes. Individual samples from Mars are expected to be much smaller than lunar samples, the total mass of samples returned by each mission being 0.5- 1 kg, compared with many tens of kg of lunar samples returned by each of the six Apollo missions. Smaller samples require much more of the processing to be done under microscopic observation. In addition, the requirements for cleanliness and high-level containment would be difficult to satisfy while using traditional gloveboxes. JSC has constructed a laboratory to test concepts and technologies important to future sample curation. The Advanced Curation Laboratory includes a new-generation glovebox equipped with a robotic arm to evaluate the usability of robotic and teleoperated systems to perform curatorial tasks. The laboratory also contains equipment for precision cleaning and the measurement of trace organic contamination.

  15. Technology Development and Advanced Planning for Curation of Returned Mars Samples

    NASA Astrophysics Data System (ADS)

    Lindstrom, D. J.; Allen, C. C.

    2002-05-01

    NASA/Johnson Space Center (JSC) curates extraterrestrial samples, providing the international science community with lunar rock and soil returned by the Apollo astronauts, meteorites collected in Antarctica, cosmic dust collected in the stratosphere, and hardware exposed to the space environment. Curation comprises initial characterization of new samples, preparation and allocation of samples for research, and clean, secure long-term storage. The foundations of this effort are the specialized cleanrooms (class 10 to 10,000) for each of the four types of materials, the supporting facilities, and the people, many of whom have been doing detailed work in clean environments for decades. JSC is also preparing to curate the next generation of extraterrestrial samples. These include samples collected from the solar wind, a comet, and an asteroid. Early planning and R&D are underway to support post-mission sample handling and curation of samples returned from Mars. One of the strong scientific reasons for returning samples from Mars is to search for evidence of current or past life in the samples. Because of the remote possibility that the samples may contain life forms that are hazardous to the terrestrial biosphere, the National Research Council has recommended that all samples returned from Mars be kept under strict biological containment until tests show that they can safely be released to other laboratories. It is possible that Mars samples may contain only scarce or subtle traces of life or prebiotic chemistry that could readily be overwhelmed by terrestrial contamination. Thus, the facilities used to contain, process, and analyze samples from Mars must have a combination of high-level biocontainment and organic / inorganic chemical cleanliness that is unprecedented. JSC has been conducting feasibility studies and developing designs for a sample receiving facility that would offer biocontainment at least the equivalent of current maximum containment BSL-4 (BioSafety Level 4) laboratories, while simultaneously maintaining cleanliness levels equaling those of state-of-the-art cleanrooms. Unique requirements for the processing of Mars samples have inspired a program to develop handling techniques that are much more precise and reliable than the approach (currently used for lunar samples) of employing gloved human hands in nitrogen-filled gloveboxes. Individual samples from Mars are expected to be much smaller than lunar samples, the total mass of samples returned by each mission being 0.5- 1 kg, compared with many tens of kg of lunar samples returned by each of the six Apollo missions. Smaller samples require much more of the processing to be done under microscopic observation. In addition, the requirements for cleanliness and high-level containment would be difficult to satisfy while using traditional gloveboxes. JSC has constructed a laboratory to test concepts and technologies important to future sample curation. The Advanced Curation Laboratory includes a new-generation glovebox equipped with a robotic arm to evaluate the usability of robotic and teleoperated systems to perform curatorial tasks. The laboratory also contains equipment for precision cleaning and the measurement of trace organic contamination.

  16. Dissolved pesticide concentrations detected in storm-water runoff at selected sites in the San Joaquin River basin, California, 2000-2001

    USGS Publications Warehouse

    Orlando, James L.; Kuivila, Kathryn; Whitehead, Andrew

    2003-01-01

    As part of a collaborative study involving the United States Geological Survey Toxics Substances Hydrology Project (Toxics Project) and the University of California, Davis, Bodega Marine Laboratory (BML), water samples were collected at three sites within the San Joaquin River Basin of California and analyzed for dissolved pesticides. Samples were collected during, and immediately after, the first significant rainfall (greater than 0.5 inch per day) following the local application of dormant spray, organophosphate insecticides during the winters of 2000 and 2001. All samples were collected in conjunction with fish-caging experiments conducted by BML researchers. Sites included two locations potentially affected by runoff of agricultural chemicals (San Joaquin River near Vernalis, California, and Orestimba Creek at River Road near Crows Landing, California, and one control site located upstream of pesticide input (Orestimba Creek at Orestimba Creek Road near Newman, California). During these experiments, fish were placed in cages and exposed to storm runoff for up to ten days. Following exposure, the fish were examined for acetylcholinesterase concentrations and overall genetic damage. Water samples were collected throughout the rising limb of the stream hydrograph at each site for later pesticide analysis. Concentrations of selected pesticides were measured in filtered water samples using solid-phase extraction (SPE) and gas chromatography-mass spectrometry (GC/MS) at the U.S. Geological Survey organic chemistry laboratory in Sacramento, California. Results of these analyses are presented.

  17. Surface- and Ground-Water Monitoring and Mapping of Selected Features at the Blue Ridge Parkway Mt. Pisgah Campground, Haywood County, North Carolina, 2002

    DTIC Science & Technology

    2004-01-01

    information throughout the duration of the study. Much appreciation is expressed to Gary Francis of the North Carolina Department of Environment and...and others, 2002). Samples collected for fecal coliform bacteria were analyzed by the North Carolina Department of Environment and Natural...on September 11 and analyzed by the North Carolina Department of Environment and Natural Resources laboratory in Asheville. Samples collected from

  18. Handwashing and antiseptic-containing soaps in hospital

    PubMed Central

    Jarvis, J. D.; Wynne, C. D.; Enwright, L.; Williams, J. D.

    1979-01-01

    Two aspects of handwashing in hospital were considered. A study was carried out to examine the contamination of bar soap and containers, and the use of antiseptic soaps in reducing the resident flora of the skin. Swabs were collected from soap dishes on six wards and from a bacteriology laboratory on four consecutive days. The unmedicated bar soap was replaced by bar soap containing 2·5% povidone-iodine, and further swabs were collected over a period of seven days. Ninety-two isolates from 48 samples were obtained when unmedicated bar soap was used, and nine isolates from 42 samples when povidone-iodine (Betadine) soap was substituted. The number of organisms recovered when povidone-iodine soap was used was much reduced, and Pseudomonas spp were recovered in low numbers on only one occasion. Six laboratory workers took part in a study to compare bar soap with other agents—povidone-iodine soap, povidone-iodine surgical scrub, povidone-iodine alcoholic solution, chlorhexidine surgical scrub, and alcoholic chlorhexidine. Samples were collected after standard washes and after surgical gloves had been worn for 90 minutes. The effect of multiple washes was assessed by samples collected after six washes with the agent under study (three per day) followed by 90 minutes wearing surgical gloves. The average percentage reduction in normal flora obtained indicated that alcoholic chlorhexidine was superior to the other agents. PMID:500840

  19. NextGen Home Sperm Banking Kit: Outcomes of Offsite vs Onsite Collection--Preliminary Findings.

    PubMed

    Agarwal, Ashok; Sharma, Reecha; Gupta, Sajal; Sharma, Rakesh

    2015-06-01

    To compare cryosurvival rates between remote collections with NextGen kit (offsite) and onsite collection of semen samples from infertile men and those with cancer. Prefreeze and post-thaw sperm motility, total motile sperm, and percent cryosurvival rates were compared between samples collected from infertile men onsite at the Andrology Center (n = 10) and samples collected from infertile patients at home (offsite; n = 9), which were shipped by NextGen to our laboratory. A second group (n = 17) consisted of 10 semen samples from cancer patients collected onsite, which were compared with 7 semen samples from cancer patients shipped by the NextGen. All semen samples were assessed within 18 hours of collection. In the infertile men, percent cryosurvival rates were similar with NextGen compared with those of onsite collection (53.14 ± 28.9% vs 61.90 ± 20.46%; P = .51). Similarly, in the cancer patients, all 4 parameters were comparable between the onsite and NextGen. Cryosurvival rates were also similar between NextGen compared with those of onsite collection (52.71 ± 20.37% vs 58.90 ± 22.68%; P = .46). Cancer patients can bank sperm as effectively as men banking for infertility reasons using the NextGen kit. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Questa baseline and pre-mining ground-water quality investigation. 2. Low-flow (2001) and snowmelt (2002) synoptic/tracer water chemistry for the Red River, New Mexico

    USGS Publications Warehouse

    McCleskey, R. Blaine; Nordstrom, D. Kirk; Steiger, Judy I.; Kimball, Briant A.; Verplanck, Philip L.

    2003-01-01

    Water analyses are reported for 259 samples collected from the Red River, New Mexico, and its tributaries during low-flow(2001) and spring snowmelt (2002) tracer studies. Water samples were collected along a 20-kilometer reach of the Red River beginning just east of the town of Red River and ending at the U.S. Geological Survey streamflow-gaging station located east of Questa, New Mexico. The study area was divided into three sections where separate injections and synoptic sampling events were performed during the low-flow tracer study. During the spring snowmelt tracer study, three tracer injections and synoptic sampling events were performed bracketing the areas with the greatest metal loading into the Red River as determined from the low-flow tracer study. The lowflow tracer synoptic sampling events were August 17, 20, and 24, 2001. The synoptic sampling events for the spring snowmelt tracer were March 30, 31, and April 1, 2002. Stream and large inflow water samples were sampled using equal-width and depth-integrated sampling methods and composited into half-gallon bottles. Grab water samples were collected from smaller inflows. Stream temperatures were measured at the time of sample collection. Samples were transported to a nearby central processing location where pH and specific conductance were measured and the samples processed for chemical analyses. Cations, trace metals, iron redox species, and fluoride were analyzed at the U.S. Geological Survey laboratory in Boulder, Colorado. Cations and trace metal concentrations were determined using inductively coupled plasma-optical emission spectrometry and graphite furnace atomic absorption spectrometry. Arsenic concentrations were determined using hydride generation atomic absorption spectrometry, iron redox species were measured using ultraviolet-visible spectrometry, and fluoride concentrations were determined using an ion-selective electrode. Alkalinity was measured by automated titration, and sulfate, chloride, and bromide were analyzed by ion chromatography at the U.S. Geological Survey laboratory in Salt Lake City, Utah.

  1. Data from a solute transport experiment in the Leviathan Mine drainage, Alpine County, California, October 1982

    USGS Publications Warehouse

    Flint, M.R.; Bencala, K.E.; Zellweger, G.W.; Hammermeister, D.P.

    1985-01-01

    A twenty-four hour injection of chloride and sodium was made into Leviathan Creek, Alpine County, California to aid interpretation of the coupled interactions between physical transport processes and geochemical reactions. Leviathan Creek was chosen because it receives acid mine drainage from Leviathan Mine, an abandoned open-pit sulfur mine. Water samples were collected at 15 sites along a 4.39 kilometer reach and analyzed for chloride, sodium, sulfate and fluoride. Dissolved concentrations are presented in tabular format and time-series plots. Duplicate samples were analyzed by two laboratories: the Central Laboratory, Denver, Colorado and a research laboratory in Menlo Park, California. A tabular comparison of the analyses and plots of the differences between the two laboratories is presented. Hydrographs and instantaneous discharge measurements are included. (USGS)

  2. A detailed characterization of the Saharan dust collected during the Fennec campaign in 2011: in situ ground-based and laboratory measurements

    NASA Astrophysics Data System (ADS)

    Rocha-Lima, Adriana; Vanderlei Martins, J.; Remer, Lorraine A.; Todd, Martin; Marsham, John H.; Engelstaedter, Sebastian; Ryder, Claire L.; Cavazos-Guerra, Carolina; Artaxo, Paulo; Colarco, Peter; Washington, Richard

    2018-01-01

    Millions of tons of mineral dust are lifted by the wind from arid surfaces and transported around the globe every year. The physical and chemical properties of the mineral dust are needed to better constrain remote sensing observations and are of fundamental importance for the understanding of dust atmospheric processes. Ground-based in situ measurements and in situ filter collection of Saharan dust were obtained during the Fennec campaign in the central Sahara in 2011. This paper presents results of the absorption and scattering coefficients, and hence single scattering albedo (SSA), of the Saharan dust measured in real time during the last period of the campaign and subsequent laboratory analysis of the dust samples collected in two supersites, SS1 and SS2, in Algeria and in Mauritania, respectively. The samples were taken to the laboratory, where their size and aspect ratio distributions, mean chemical composition, spectral mass absorption efficiency, and spectral imaginary refractive index were obtained from the ultraviolet (UV) to the near-infrared (NIR) wavelengths. At SS1 in Algeria, the time series of the scattering coefficients during the period of the campaign show dust events exceeding 3500 Mm-1, and a relatively high mean SSA of 0.995 at 670 nm was observed at this site. The laboratory results show for the fine particle size distributions (particles diameter  < 5µm and mode diameter at 2-3 µm) in both sites a spectral dependence of the imaginary part of the refractive index Im(m) with a bow-like shape, with increased absorption in UV as well as in the shortwave infrared. The same signature was not observed, however, in the mixed particle size distribution (particle diameter < 10 µm and mode diameter at 4 µm) in Algeria. Im(m) was found to range from 0.011 to 0.001i for dust collected in Algeria and 0.008 to 0.002i for dust collected in Mauritania over the wavelength range of 350-2500 nm. Differences in the mean elemental composition of the dust collected in the supersites in Algeria and in Mauritania and between fine and mixed particle size distributions were observed from EDXRF measurements, although those differences cannot be used to explain the optical properties variability between the samples. Finally, particles with low-density typically larger than 10 µm in diameter were found in some of the samples collected at the supersite in Mauritania, but these low-density particles were not observed in Algeria.

  3. Colloidal-facilitated transport of inorganic contaminants in ground water: part 1, sampling considerations

    USGS Publications Warehouse

    Puls, Robert W.; Eychaner, James H.; Powell, Robert M.

    1996-01-01

    Investigations at Pinal Creek, Arizona, evaluated routine sampling procedures for determination of aqueous inorganic geochemistry and assessment of contaminant transport by colloidal mobility. Sampling variables included pump type and flow rate, collection under air or nitrogen, and filter pore diameter. During well purging and sample collection, suspended particle size and number as well as dissolved oxygen, temperature, specific conductance, pH, and redox potential were monitored. Laboratory analyses of both unfiltered samples and the filtrates were performed by inductively coupled argon plasma, atomic absorption with graphite furnace, and ion chromatography. Scanning electron microscopy with Energy Dispersive X-ray was also used for analysis of filter particulates. Suspended particle counts consistently required approximately twice as long as the other field-monitored indicators to stabilize. High-flow-rate pumps entrained normally nonmobile particles. Difference in elemental concentrations using different filter-pore sizes were generally not large with only two wells having differences greater than 10 percent in most wells. Similar differences (>10%) were observed for some wells when samples were collected under nitrogen rather than in air. Fe2+/Fe3+ ratios for air-collected samples were smaller than for samples collected under a nitrogen atmosphere, reflecting sampling-induced oxidation.

  4. Arsenic exposure in drinking water: an unrecognized health threat in Peru.

    PubMed

    George, Christine Marie; Sima, Laura; Arias, M Helena Jahuira; Mihalic, Jana; Cabrera, Lilia Z; Danz, David; Checkley, William; Gilman, Robert H

    2014-08-01

    To assess the extent of arsenic contamination of groundwater and surface water in Peru and, to evaluate the accuracy of the Arsenic Econo-Quick(™) (EQ) kit for measuring water arsenic concentrations in the field. Water samples were collected from 151 water sources in 12 districts of Peru, and arsenic concentrations were measured in the laboratory using inductively-coupled plasma mass spectrometry. The EQ field kit was validated by comparing a subset of 139 water samples analysed by laboratory measurements and the EQ kit. In 86% (96/111) of the groundwater samples, arsenic exceeded the 10 µg/l arsenic concentration guideline given by the World Health Organization (WHO) for drinking water. In 56% (62/111) of the samples, it exceeded the Bangladeshi threshold of 50 µg/l; the mean concentration being 54.5 µg/l (range: 0.1-93.1). In the Juliaca and Caracoto districts, in 96% (27/28) of groundwater samples arsenic was above the WHO guideline; and in water samples collected from the section of the Rímac river running through Lima, all had arsenic concentrations exceeding the WHO limit. When validated against laboratory values, the EQ kit correctly identified arsenic contamination relative to the guideline in 95% (106/111) of groundwater and in 68% (19/28) of surface water samples. In several districts of Peru, drinking water shows widespread arsenic contamination, exceeding the WHO arsenic guideline. This poses a public health threat requiring further investigation and action. For groundwater samples, the EQ kit performed well relative to the WHO arsenic limit and therefore could provide a vital tool for water arsenic surveillance.

  5. The Perils of Paul: Near Disasters in Airborne Radiochemical Sampling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meade, Roger Allen

    Beginning with the Trinity test in July 1945, Laboratory radiochemists have collected debris from nuclear tests by various means. At Trinity, two United States Army Sherman tanks were used. Beginning with Operation Crossroads and continuing throughout atmospheric testing, aircraft were used to fly in and around mushroom clouds to collect debris. Paul Guthals, the LASL project leader for sampling operations, flew on many of the B-57 sampling missions. Two such missions, one flown over the Nevada Test and one in the skies near Johnston Atoll, again proved the dangers involved in collecting airborne test debris. The events of these twomore » missions are briefly recounted.« less

  6. Soils element activities for the period October 1973--September 1974

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fowler, E.B.; Essington, E.H.; White, M.G.

    Soils Element activities were conducted on behalf of the U. S. Atomic Energy Commission's Nevada Applied Ecology Group (NAEG) program to provide source term information for the other program elements and maintain continuous cognizance of program requirements for sampling, sample preparation, and analysis. Activities included presentation of papers; participation in workshops; analysis of soil, vegetation, and animal tissue samples for $sup 238$Pu, $sup 239-240$Pu, $sup 241$Am, $sup 137$Cs, $sup 60$Co, and gamma scan for routine and laboratory quality control purposes; preparation and analysis of animal tissue samples for NAEG laboratory certification; studies on a number of analytical, sample preparation, andmore » sample collection procedures; and contributions to the evaluation of procedures for calculation of specialized counting statistics. (auth)« less

  7. Standardization of collection requirements for fasting samples: for the Working Group on Preanalytical Phase (WG-PA) of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM).

    PubMed

    Simundic, A M; Cornes, M; Grankvist, K; Lippi, G; Nybo, M

    2014-05-15

    Standardized protocols for patient preparation for laboratory testing are currently lacking. Moreover, a great heterogeneity exists in the definitions of "fasting" currently being used among healthcare workers and in the literature. Marked metabolic and hormonal changes occur after food ingestion, mainly due to the absorption of fluids, lipids, proteins, carbohydrates and other food constituents. This postprandial response varies markedly in response to numerous factors, such as eating behavior, food composition, fasting duration, time of the day, chronic and acute smoking, coffee and alcohol consumption. It is therefore crucial to minimize the total variability by controlling as many of these modifying factors as possible. Control of the abovementioned effects on postprandial response can only be achieved by standardizing the way patients are prepared for laboratory testing, i.e. by defining the fasting duration, as well as what is and what is not allowed (e.g., coffee, tea, smoking, water) during the period of fasting prior to sample collection. The aim of this article is to describe the range of effects of different approaches to fasting on laboratory tests, and to provide a framework for the harmonization of definitions for fasting requirements for laboratory tests. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Water-Chemistry and On-Site Sulfur-Speciation Data for Selected Springs in Yellowstone National Park, Wyoming, 1996-1998

    USGS Publications Warehouse

    Ball, James W.; Nordstrom, D. Kirk; McCleskey, R. Blaine; Schoonen, Martin A.A.; Xu, Yong

    2001-01-01

    Fifty-eight water analyses are reported for samples collected from 19 hot springs and their overflow drainages and one ambient-temperature acid stream in Yellowstone National Park (YNP) during 1996-98. These water samples were collected and analyzed as part of research investigations on microbially mediated sulfur oxidation in stream waters and sulfur redox speciation in hot springs in YNP and chemical changes in overflow drainages that affect major ions, redox species, and trace elements. The research on sulfur redox speciation in hot springs is a collaboration with the State University of New York at Stony Brook, Northern Arizona University, and the U.S. Geological Survey (USGS). One ambient-temperature acidic stream system, Alluvium Creek and its tributaries in Brimstone Basin, was studied in detail. Analyses were performed adjacent to the sampling site, in an on-site mobile laboratory truck, or later in a USGS laboratory, depending on stability and preservability of the constituent. Water temperature, specific conductance, pH, Eh, dissolved oxygen (D.O.), and dissolved H2S were determined on-site at the time of sampling. Alkalinity and F were determined within a few days of sample collection by titration and by ion-selective electrode, respectively. Concentrations of S2O3 and SxO6 were determined as soon as possible (minutes to hours later) by ion chromatography (IC). Concentrations of Cl, SO4, and Br were determined by IC within a few days of sample collection. Concentrations of Fe(II) and Fe(total) were determined by ultraviolet/visible spectrophotometry within a few days of sample collection. Densities were determined later in the USGS laboratory. Concentrations of Li, Na, and K were determined by flame atomic absorption (Li) and emission (Na, K) spectrometry. Concentrations of Al, As(total), B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe(total), Mg, Mn, Ni, Pb, Si, Sr, V, and Zn were determined by inductively-coupled plasma optical emission spectrometry. Trace concentrations of Cd, Se, As(total), Ni, and Pb were determined by Zeeman-corrected graphite-furnace atomic-absorption spectrometry. Trace concentrations of As(total) and As(III) were determined by hydride generation using a flow-injection analysis system.

  9. Chemicals of emerging concern in water and bottom sediment in Great Lakes areas of concern, 2010 to 2011-Collection methods, analyses methods, quality assurance, and data

    USGS Publications Warehouse

    Lee, Kathy E.; Langer, Susan K.; Menheer, Michael A.; Foreman, William T.; Furlong, Edward T.; Smith, Steven G.

    2012-01-01

    The U.S. Geological Survey (USGS) cooperated with the U.S. Environmental Protection Agency and the U.S. Fish and Wildlife Service on a study to identify the occurrence of chemicals of emerging concern (CECs) in water and bottom-sediment samples collected during 2010–11 at sites in seven areas of concern (AOCs) throughout the Great Lakes. Study sites include tributaries to the Great Lakes in AOCs located near Duluth, Minn.; Green Bay, Wis.; Roches­ter, N.Y.; Detroit, Mich.; Toledo, Ohio; Milwaukee, Wis.; and Ashtabula, Ohio. This report documents the collection meth­ods, analyses methods, quality-assurance data and analyses, and provides the data for this study. Water and bottom-sediment samples were analyzed at the USGS National Water Quality Laboratory in Denver, Colo., for a broad suite of CECs. During this study, 135 environmental and 23 field dupli­cate samples of surface water and wastewater effluent, 10 field blank water samples, and 11 field spike water samples were collected and analyzed. Sixty-one of the 69 wastewater indicator chemicals (laboratory method 4433) analyzed were detected at concentrations ranging from 0.002 to 11.2 micrograms per liter. Twenty-eight of the 48 pharmaceuticals (research method 8244) analyzed were detected at concentrations ranging from 0.0029 to 22.0 micro­grams per liter. Ten of the 20 steroid hormones and sterols analyzed (research method 4434) were detected at concentrations ranging from 0.16 to 10,000 nanograms per liter. During this study, 75 environmental, 13 field duplicate samples, and 9 field spike samples of bottom sediment were collected and analyzed for a wide variety of CECs. Forty-seven of the 57 wastewater indicator chemicals (laboratory method 5433) analyzed were detected at concentrations ranging from 0.921 to 25,800 nanograms per gram. Seventeen of the 20 steroid hormones and sterols (research method 6434) analyzed were detected at concentrations ranging from 0.006 to 8,921 nanograms per gram. Twelve of the 20 pharmaceuticals (research method 8244) analyzed were detected at concentrations ranging from 2.35 to 453.5 nanograms per gram. Six of the 11 antidepressants (research method 9008) analyzed were detected at concentrations ranging from 2.79 to 91.6 nanograms per gram.

  10. Operational Procedures for Collecting Water-Quality Samples at Monitoring Sites on Maple Creek Near Nickerson and the Platte River at Louisville, Eastern Nebraska

    USGS Publications Warehouse

    Johnson, Steven M.; Swanson, Robert B.

    1994-01-01

    Prototype stream-monitoring sites were operated during part of 1992 in the Central Nebraska Basins (CNBR) and three other study areas of the National Water-Quality Assessment (NAWQ) Program of the U.S. Geological Survey. Results from the prototype project provide information needed to operate a net- work of intensive fixed station stream-monitoring sites. This report evaluates operating procedures for two NAWQA prototype sites at Maple Creek near Nickerson and the Platte River at Louisville, eastern Nebraska. Each site was sampled intensively in the spring and late summer 1992, with less intensive sampling in midsummer. In addition, multiple samples were collected during two high- flow periods at the Maple Creek site--one early and the other late in the growing season. Water-samples analyses included determination of pesticides, nutrients, major ions, suspended sediment, and measurements of physical properties. Equipment and protocols for the water-quality sampling procedures were evaluated. Operation of the prototype stream- monitoring sites included development and comparison of onsite and laboratory sample-processing proce- dures. Onsite processing was labor intensive but allowed for immediate preservation of all sampled constituents. Laboratory processing required less field labor and decreased the risk of contamination, but allowed for no immediate preservation of the samples.

  11. Inventory Control.

    ERIC Educational Resources Information Center

    Rich, Joe, Ed.

    1990-01-01

    Described are the design, construction, and uses of two pieces of laboratory equipment. Included are a multipurpose meter, "Calo-pH Meter," and a device for collecting water samples for determining dissolved oxygen content. (CW)

  12. Estimation of the Rate of Unrecognized Cross-Contamination with Mycobacterium tuberculosis in London Microbiology Laboratories

    PubMed Central

    Ruddy, M.; McHugh, T. D.; Dale, J. W.; Banerjee, D.; Maguire, H.; Wilson, P.; Drobniewski, F.; Butcher, P.; Gillespie, S. H.

    2002-01-01

    Isolates from patients with confirmed tuberculosis from London were collected over 2.5 years between 1995 and 1997. Restriction fragment length polymorphism (RFLP) analysis was performed by the international standard technique as part of a multicenter epidemiological study. A total of 2,779 samples representing 2,500 individual patients from 56 laboratories were examined. Analysis of these samples revealed a laboratory cross-contamination rate of between 0.54%, when only presumed cases of cross-contamination were considered, and 0.93%, when presumed and possible cases were counted. Previous studies suggest an extremely wide range of laboratory cross-contamination rates of between 0.1 and 65%. These data indicate that laboratory cross-contamination has not been a common problem in routine practice in the London area, but in several incidents patients did receive full courses of therapy that were probably unnecessary. PMID:12409381

  13. Evaluation of airborne asbestos exposure from routine handling of asbestos-containing wire gauze pads in the research laboratory.

    PubMed

    Garcia, Ediberto; Newfang, Daniel; Coyle, Jayme P; Blake, Charles L; Spencer, John W; Burrelli, Leonard G; Johnson, Giffe T; Harbison, Raymond D

    2018-07-01

    Three independently conducted asbestos exposure evaluations were conducted using wire gauze pads similar to standard practice in the laboratory setting. All testing occurred in a controlled atmosphere inside an enclosed chamber simulating a laboratory setting. Separate teams consisting of a laboratory technician, or technician and assistant simulated common tasks involving wire gauze pads, including heating and direct wire gauze manipulation. Area and personal air samples were collected and evaluated for asbestos consistent with the National Institute of Occupational Safety Health method 7400 and 7402, and the Asbestos Hazard Emergency Response Act (AHERA) method. Bulk gauze pad samples were analyzed by Polarized Light Microscopy and Transmission Electron Microscopy to determine asbestos content. Among air samples, chrysotile asbestos was the only fiber found in the first and third experiments, and tremolite asbestos for the second experiment. None of the air samples contained asbestos in concentrations above the current permissible regulatory levels promulgated by OSHA. These findings indicate that the level of asbestos exposure when working with wire gauze pads in the laboratory setting is much lower than levels associated with asbestosis or asbestos-related lung cancer and mesothelioma. Copyright © 2018. Published by Elsevier Inc.

  14. GHSI EMERGENCY RADIONUCLIDE BIOASSAY LABORATORY NETWORK: SUMMARY OF A RECENT EXERCISE.

    PubMed

    Li, Chunsheng; Ansari, Armin; Bartizel, Christine; Battisti, Paolo; Franck, Didier; Gerstmann, Udo; Giardina, Isabella; Guichet, Claude; Hammond, Derek; Hartmann, Martina; Jones, Robert L; Kim, Eunjoo; Ko, Raymond; Morhard, Ryan; Quayle, Deborah; Sadi, Baki; Saunders, David; Paquet, Francois

    2016-11-01

    The Global Health Security Initiative (GHSI) established a laboratory network within the GHSI community to develop their collective surge capacity for radionuclide bioassay in response to a radiological or nuclear emergency. A recent exercise was conducted to test the participating laboratories for their capabilities in screening and in vitro assay of biological samples, performing internal dose assessment and providing advice on medical intervention, if necessary, using a urine sample spiked with a single radionuclide, 241 Am. The laboratories were required to submit their reports according to the exercise schedule and using pre-formatted templates. Generally, the participating laboratories were found to be capable with respect to rapidly screening samples for radionuclide contamination, measuring the radionuclide in the samples, assessing the intake and radiation dose, and providing advice on medical intervention. However, gaps in bioassay measurement and dose assessment have been identified. The network may take steps to ensure that procedures and practices within this network be harmonised and a follow-up exercise be organised on a larger scale, with potential participation of laboratories from the networks coordinated by the International Atomic Energy Agency and the World Health Organization. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Evaluation of quality-control data collected by the U.S. Geological Survey for routine water-quality activities at the Idaho National Laboratory and vicinity, southeastern Idaho, 2002-08

    USGS Publications Warehouse

    Rattray, Gordon W.

    2014-01-01

    Quality-control (QC) samples were collected from 2002 through 2008 by the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, to ensure data robustness by documenting the variability and bias of water-quality data collected at surface-water and groundwater sites at and near the Idaho National Laboratory. QC samples consisted of 139 replicates and 22 blanks (approximately 11 percent of the number of environmental samples collected). Measurements from replicates were used to estimate variability (from field and laboratory procedures and sample heterogeneity), as reproducibility and reliability, of water-quality measurements of radiochemical, inorganic, and organic constituents. Measurements from blanks were used to estimate the potential contamination bias of selected radiochemical and inorganic constituents in water-quality samples, with an emphasis on identifying any cross contamination of samples collected with portable sampling equipment. The reproducibility of water-quality measurements was estimated with calculations of normalized absolute difference for radiochemical constituents and relative standard deviation (RSD) for inorganic and organic constituents. The reliability of water-quality measurements was estimated with pooled RSDs for all constituents. Reproducibility was acceptable for all constituents except dissolved aluminum and total organic carbon. Pooled RSDs were equal to or less than 14 percent for all constituents except for total organic carbon, which had pooled RSDs of 70 percent for the low concentration range and 4.4 percent for the high concentration range. Source-solution and equipment blanks were measured for concentrations of tritium, strontium-90, cesium-137, sodium, chloride, sulfate, and dissolved chromium. Field blanks were measured for the concentration of iodide. No detectable concentrations were measured from the blanks except for strontium-90 in one source solution and one equipment blank collected in September and October 2004, respectively. The detectable concentrations of strontium-90 in the blanks probably were from a small source of strontium-90 contamination or large measurement variability, or both. Order statistics and the binomial probability distribution were used to estimate the magnitude and extent of any potential contamination bias of tritium, strontium-90, cesium-137, sodium, chloride, sulfate, dissolved chromium, and iodide in water-quality samples. These statistical methods indicated that, with (1) 87 percent confidence, contamination bias of cesium-137 and sodium in 60 percent of water-quality samples was less than the minimum detectable concentration or reporting level; (2) 92‒94 percent confidence, contamination bias of tritium, strontium-90, chloride, sulfate, and dissolved chromium in 70 percent of water-quality samples was less than the minimum detectable concentration or reporting level; and (3) 75 percent confidence, contamination bias of iodide in 50 percent of water-quality samples was less than the reporting level for iodide. These results support the conclusion that contamination bias of water-quality samples from sample processing, storage, shipping, and analysis was insignificant and that cross-contamination of perched groundwater samples collected with bailers during 2002–08 was insignificant.

  16. Comet Odyssey: Comet Surface Sample Return

    NASA Astrophysics Data System (ADS)

    Weissman, Paul R.; Bradley, J.; Smythe, W. D.; Brophy, J. R.; Lisano, M. E.; Syvertson, M. L.; Cangahuala, L. A.; Liu, J.; Carlisle, G. L.

    2010-10-01

    Comet Odyssey is a proposed New Frontiers mission that would return the first samples from the surface of a cometary nucleus. Stardust demonstrated the tremendous power of analysis of returned samples in terrestrial laboratories versus what can be accomplished in situ with robotic missions. But Stardust collected only 1 milligram of coma dust, and the 6.1 km/s flyby speed heated samples up to 2000 K. Comet Odyssey would collect two independent 800 cc samples directly from the surface in a far more benign manner, preserving the primitive composition. Given a minimum surface density of 0.2 g/cm3, this would return two 160 g surface samples to Earth. Comet Odyssey employs solar-electric propulsion to rendezvous with the target comet. After 180 days of reconnaissance and site selection, the spacecraft performs a "touch-and-go” maneuver with surface contact lasting 3 seconds. A brush-wheel sampler on a remote arm collects up to 800 cc of sample. A duplicate second arm and sampler collects the second sample. The samples are placed in a return capsule and maintained at colder than -70 C during the return flight and at colder than -30 C during re-entry and for up to six hours after landing. The entire capsule is then refrigerated and transported to the Astromaterials Curatorial Facility at NASA/JSC for initial inspection and sample analysis by the Comet Odyssey team. Comet Odyssey's planned target was comet 9P/Tempel 1, with launch in December 2017 and comet arrival in June 2022. After a stay of 300 days at the comet, the spacecraft departs and arrives at Earth in May 2027. Comet Odyssey is a forerunner to a flagship Cryogenic Comet Sample Return mission that would return samples from deep below the nucleus surface, including volatile ices. This work was supported by internal funds from the Jet Propulsion Laboratory.

  17. Swab or biopsy samples for bioburden testing of allograft musculoskeletal tissue?

    PubMed

    Varettas, Kerry

    2014-12-01

    Swab and biopsy samples of allograft musculoskeletal tissue are most commonly collected by tissue banks for bacterial and fungal bioburden testing. An in vitro study was performed using the National Committee for Clinical Laboratory Standards standard 'Quality control of microbiological transport systems' (2003) to validate and evaluate the recovery of six challenge organisms from swab and biopsy samples of allograft musculoskeletal tissue. On average, 8.4 to >100 and 7.2 to >100 % of the inoculum was recovered from swab and biopsy samples respectively. A retrospective review of donor episodes was also performed, consisting of paired swab and biopsy samples received in this laboratory during the period 2001-2012. Samples of allograft femoral heads were collected from living donors during hip operations. From the 3,859 donor episodes received, 21 paired swab and biopsy samples each recovered an isolate, 247 swab samples only and 79 biopsy samples only were culture positive. Low numbers of challenge organisms were recovered from inoculated swab and biopsy samples in the in vitro study and validated their use for bioburden testing of allograft musculoskeletal tissue. Skin commensals were the most common group of organisms isolated during a 12-year retrospective review of paired swab and biopsy samples from living donor allograft femoral heads. Paired swab and biopsy samples are a suitable representative sample of allograft musculoskeletal tissue for bioburden testing.

  18. Radionuclide concentrations in honey bees from Area G at TA-54 during 1997. Progress report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haarmann, T.K.; Fresquez, P.R.

    Honey bees were collected from two colonies located at Los Alamos National Laboratory`s Area G, Technical Area 54, and from one control (background) colony located near Jamez Springs, NM. Samples were analyzed for the following: cesium ({sup 137}Cs), americium ({sup 241}Am), plutonium ({sup 238}Pu and {sup 239,240}Pu), tritium ({sup 3}H), total uranium, and gross gamma activity. Area G sample results from both colonies were higher than the upper (95%) level background concentration for {sup 238}Pu and {sup 3}H.

  19. 1QCY17 Saltstone waste characterization analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, F. C.

    2017-07-25

    In the first quarter of calendar year 2017, a salt solution sample was collected from Tank 50 on January 16, 2017 in order to meet South Carolina (SC) Regulation 61-107.19 Part I C, “Solid Waste Management: Solid Waste Landfills and Structural Fill – General Requirements” and the Saltstone Disposal Facility Class 3 Landfill Permit. The Savannah River National Laboratory (SRNL) was requested to prepare and ship saltstone samples to a United States Environmental Protection Agency (EPA) certified laboratory to perform the Toxicity Characteristic Leaching Procedure (TCLP) and subsequent characterization.

  20. Evaluation of a New Spraying Machine for Barrier Treatment and Penetration of Bifenthrin on Vegetation Against Mosquitoes

    DTIC Science & Technology

    2015-03-01

    one at the University of Florida Veterinary Entomology Laboratory (UF- VEL). Leaf samples for both laboratories were collected together. All samples...Mulla’s formula (Mulla et al. 1971): % reduction 5 100 2 (C1/T1 3 T2/C2) 3 100. The C1 variable was the mean number of mosquitoes from the control site...statistical analysis was performed using JMP 11.1 software (SAS Insti- tute Inc., Cary, NC). Treatment mortality was corrected with Abbott’s formula

  1. The development of a Martian atmospheric Sample collection canister

    NASA Astrophysics Data System (ADS)

    Kulczycki, E.; Galey, C.; Kennedy, B.; Budney, C.; Bame, D.; Van Schilfgaarde, R.; Aisen, N.; Townsend, J.; Younse, P.; Piacentine, J.

    The collection of an atmospheric sample from Mars would provide significant insight to the understanding of the elemental composition and sub-surface out-gassing rates of noble gases. A team of engineers at the Jet Propulsion Laboratory (JPL), California Institute of Technology have developed an atmospheric sample collection canister for Martian application. The engineering strategy has two basic elements: first, to collect two separately sealed 50 cubic centimeter unpressurized atmospheric samples with minimal sensing and actuation in a self contained pressure vessel; and second, to package this atmospheric sample canister in such a way that it can be easily integrated into the orbiting sample capsule for collection and return to Earth. Sample collection and integrity are demonstrated by emulating the atmospheric collection portion of the Mars Sample Return mission on a compressed timeline. The test results achieved by varying the pressure inside of a thermal vacuum chamber while opening and closing the valve on the sample canister at Mars ambient pressure. A commercial off-the-shelf medical grade micro-valve is utilized in the first iteration of this design to enable rapid testing of the system. The valve has been independently leak tested at JPL to quantify and separate the leak rates associated with the canister. The results are factored in to an overall system design that quantifies mass, power, and sensing requirements for a Martian atmospheric Sample Collection (MASC) canister as outlined in the Mars Sample Return mission profile. Qualitative results include the selection of materials to minimize sample contamination, preliminary science requirements, priorities in sample composition, flight valve selection criteria, a storyboard from sample collection to loading in the orbiting sample capsule, and contributions to maintaining “ Earth” clean exterior surfaces on the orbiting sample capsule.

  2. Use of Chironomidae (Diptera) Surface-Floating Pupal Exuviae as a Rapid Bioassessment Protocol for Water Bodies

    PubMed Central

    Kranzfelder, Petra; Anderson, Alyssa M.; Egan, Alexander T.; Mazack, Jane E.; Bouchard,, R. William; Rufer, Moriya M.; Ferrington,, Leonard C.

    2015-01-01

    Rapid bioassessment protocols using benthic macroinvertebrate assemblages have been successfully used to assess human impacts on water quality. Unfortunately, traditional benthic larval sampling methods, such as the dip-net, can be time-consuming and expensive. An alternative protocol involves collection of Chironomidae surface-floating pupal exuviae (SFPE). Chironomidae is a species-rich family of flies (Diptera) whose immature stages typically occur in aquatic habitats. Adult chironomids emerge from the water, leaving their pupal skins, or exuviae, floating on the water’s surface. Exuviae often accumulate along banks or behind obstructions by action of the wind or water current, where they can be collected to assess chironomid diversity and richness. Chironomids can be used as important biological indicators, since some species are more tolerant to pollution than others. Therefore, the relative abundance and species composition of collected SFPE reflect changes in water quality. Here, methods associated with field collection, laboratory processing, slide mounting, and identification of chironomid SFPE are described in detail. Advantages of the SFPE method include minimal disturbance at a sampling area, efficient and economical sample collection and laboratory processing, ease of identification, applicability in nearly all aquatic environments, and a potentially more sensitive measure of ecosystem stress. Limitations include the inability to determine larval microhabitat use and inability to identify pupal exuviae to species if they have not been associated with adult males. PMID:26274889

  3. Use of Chironomidae (Diptera) Surface-Floating Pupal Exuviae as a Rapid Bioassessment Protocol for Water Bodies.

    PubMed

    Kranzfelder, Petra; Anderson, Alyssa M; Egan, Alexander T; Mazack, Jane E; Bouchard, R William; Rufer, Moriya M; Ferrington, Leonard C

    2015-07-24

    Rapid bioassessment protocols using benthic macroinvertebrate assemblages have been successfully used to assess human impacts on water quality. Unfortunately, traditional benthic larval sampling methods, such as the dip-net, can be time-consuming and expensive. An alternative protocol involves collection of Chironomidae surface-floating pupal exuviae (SFPE). Chironomidae is a species-rich family of flies (Diptera) whose immature stages typically occur in aquatic habitats. Adult chironomids emerge from the water, leaving their pupal skins, or exuviae, floating on the water's surface. Exuviae often accumulate along banks or behind obstructions by action of the wind or water current, where they can be collected to assess chironomid diversity and richness. Chironomids can be used as important biological indicators, since some species are more tolerant to pollution than others. Therefore, the relative abundance and species composition of collected SFPE reflect changes in water quality. Here, methods associated with field collection, laboratory processing, slide mounting, and identification of chironomid SFPE are described in detail. Advantages of the SFPE method include minimal disturbance at a sampling area, efficient and economical sample collection and laboratory processing, ease of identification, applicability in nearly all aquatic environments, and a potentially more sensitive measure of ecosystem stress. Limitations include the inability to determine larval microhabitat use and inability to identify pupal exuviae to species if they have not been associated with adult males.

  4. Effects of delayed laboratory processing on platelet serotonin levels.

    PubMed

    Sanner, Jennifer E; Frazier, Lorraine; Udtha, Malini

    2013-01-01

    Despite the availability of established guidelines for measuring platelet serotonin, these guidelines may be difficult to follow in a hospital setting where time to processing may vary from sample to sample. The purpose of this study was to evaluate the effect of the time to processing of human blood samples on the stability of the enzyme-linked immunosorbent assay (ELISA) for the determination of platelet serotonin levels in human plasma. Human blood samples collected from a convenience sample of eight healthy volunteers were analyzed to determine platelet serotonin levels from plasma collected in ethylene diamine tetra acetic acid (EDTA) tubes and stored at 4°C for 3 hr, 5 hr, 8 hr, and 12 hr. Refrigeration storage at 4°C for 3 hr, 5 hr, 8 hr, and 12 hr altered the platelet serotonin measurement when compared to immediate processing. The bias for the samples stored at 4°C for 3 hr was 102.3 (±217.39 ng/10(9) platelets), for 5 hr was 200.1 (±132.76 ng/10(9) platelets), for 8 hr was 146.9 (±221.41 ng/10(9) platelets), and for 12 hr was -67.6 (±349.60 ng/10(9) platelets). Results from this study show that accurate measurement of platelet serotonin levels is dependent on time to processing. Researchers should therefore follow a standardized laboratory guideline for obtaining immediate platelet serotonin levels after blood sample collection.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rice, K.; Bricker, O.

    The report describes the results of a study to assess the sensitivity of streams to acidic deposition in Charles and Anne Arundel Counties, Maryland using a geology-based method. Water samples were collected from streams in July and August 1988 when streams were at base-flow conditions. Eighteen water samples collected from streams in Charles County, and 17 water samples from streams in Anne Arundel County were analyzed in the field for pH, specific conductance, and acid-neutralizing capacity (ANC); 8 water samples from streams in Charles County were analyzed in the laboratory for chloride and sulfate concentrations. The assessment revealed that streamsmore » in these counties are sensitive to acidification by acidic deposition.« less

  6. Monitoring and reporting of preanalytical errors in laboratory medicine: the UK situation.

    PubMed

    Cornes, Michael P; Atherton, Jennifer; Pourmahram, Ghazaleh; Borthwick, Hazel; Kyle, Betty; West, Jamie; Costelloe, Seán J

    2016-03-01

    Most errors in the clinical laboratory occur in the preanalytical phase. This study aimed to comprehensively describe the prevalence and nature of preanalytical quality monitoring practices in UK clinical laboratories. A survey was sent on behalf of the Association for Clinical Biochemistry and Laboratory Medicine Preanalytical Working Group (ACB-WG-PA) to all heads of department of clinical laboratories in the UK. The survey captured data on the analytical platform and Laboratory Information Management System in use; which preanalytical errors were recorded and how they were classified and gauged interest in an external quality assurance scheme for preanalytical errors. Of the 157 laboratories asked to participate, responses were received from 104 (66.2%). Laboratory error rates were recorded per number of specimens, rather than per number of requests in 51% of respondents. Aside from serum indices for haemolysis, icterus and lipaemia, which were measured in 80% of laboratories, the most common errors recorded were booking-in errors (70.1%) and sample mislabelling (56.9%) in laboratories who record preanalytical errors. Of the laboratories surveyed, 95.9% expressed an interest in guidance on recording preanalytical error and 91.8% expressed interest in an external quality assurance scheme. This survey observes a wide variation in the definition, repertoire and collection methods for preanalytical errors in the UK. Data indicate there is a lot of interest in improving preanalytical data collection. The ACB-WG-PA aims to produce guidance and support for laboratories to standardize preanalytical data collection and to help establish and validate an external quality assurance scheme for interlaboratory comparison. © The Author(s) 2015.

  7. A laboratory rainfall simulator to study the soil erosion and runoff water

    NASA Astrophysics Data System (ADS)

    Cancelo González, Javier; Rial, M. E.; Díaz-Fierros, Francisco

    2010-05-01

    The soil erosion and the runoff water composition in some areas affected by forest fires or submitted to intensive agriculture are an important factor to keep an account, particularly in sensitive areas like estuary and rias that have a high importance in the socioeconomic development of some regions. An understanding of runoff production indicates the processes by which pollutants reach streams and also indicates the management techniques that might be uses to minimize the discharge of these materials into surface waters. One of the most methodology implemented in the soil erosion studies is a rainfall simulation. This method can reproduce the natural soil degradation processes in field or laboratory experiences. With the aim of improve the rainfall-runoff generation, a laboratory rainfall simulator which incorporates a fan-like intermittent water jet system for rainfall generation were modified. The major change made to the rainfall simulator consist in a system to coupling stainless steel boxes, whose dimensions are 12 x 20 x 45 centimeters, and it allows to place soil samples under the rainfall simulator. Previously these boxes were used to take soil samples in field with more of 20 centimeters of depth, causing the minimum disturbance in their properties and structure. These new implementations in the rainfall simulator also allow collect water samples of runoff in two ways: firstly, the rain water that constituted the overland flow or direct runoff and besides the rain water seeps into the soil by the process of infiltration and contributed to the subsurface runoff. Among main the variables controlled in the rainfall simulations were the soil slope and the intensity and duration of rainfall. With the aim of test the prototype, six soil samples were collected in the same sampling point and subjected to rainfall simulations in laboratory with the same intensity and duration. Two samples will constitute the control test, and they were fully undisturbed, and four samples were subjected to controlled burnings with different fire severity: two samples burnt to 250°C and the other two samples burnt to 450°C. Preliminary laboratory data of soil erosion and surface and subsurface runoff were obtained. The water parameters analysed were: pH, electrical conductivity, temperature (in the moment of sampling) and suspended sediments, ammonium, nitrates, total nitrogen (Kjeldahl method), within 24 hours after sampling.

  8. Summary of chemical data from onsite and laboratory analyses of groundwater samples from the surficial aquifer, Las Vegas, Nevada, April and August 1993 and September 1994

    USGS Publications Warehouse

    Reddy, Michael M.; Gunther, Charmaine D.

    2012-01-01

    Samples were collected from groundwater wells in and about the city of Las Vegas, Nevada, and were analyzed for selected major, minor and trace constituents. Analyses of blank and reference samples are summarized as mean and standard deviation values for all positive results.

  9. Surface-water quality in the upper San Antonio River Basin, Bexar County, Texas, 1992-98

    USGS Publications Warehouse

    Banta, J. Ryan; Slattery, Richard N.; Crow, Cassi L.

    2012-01-01

    The reported concentrations for the measured constituents varied among sites as well as between periodic and stormflow samples. Patterns for some constituents, such as nutrients, were observed; however, consistent patterns were not always observed for all analytes. For example, median concentrations for filtered ammonia, nitrate plus nitrite, organic nitrogen, and phosphorus generally were greater in periodic samples collected from the Medina and SAR Elmendorf sites as compared to samples collected from the other sites. Median concentrations of trace elements measured in periodic samples were generally less than concentrations measured in stormflow samples. In general, most of the concentrations of analyzed organic compounds were less than the laboratory reporting levels.

  10. Using Phylogenetic Analysis to Detect Market Substitution of Atlantic Salmon for Pacific Salmon: An Introductory Biology Laboratory Experiment

    ERIC Educational Resources Information Center

    Cline, Erica; Gogarten, Jennifer

    2012-01-01

    We describe a laboratory exercise developed for the cell and molecular biology quarter of a year-long majors' undergraduate introductory biology sequence. In an analysis of salmon samples collected by students in their local stores and restaurants, DNA sequencing and phylogenetic analysis were used to detect market substitution of Atlantic salmon…

  11. Uncertainty in monitoring E. coli concentrations in streams and stormwater runoff

    NASA Astrophysics Data System (ADS)

    Harmel, R. D.; Hathaway, J. M.; Wagner, K. L.; Wolfe, J. E.; Karthikeyan, R.; Francesconi, W.; McCarthy, D. T.

    2016-03-01

    Microbial contamination of surface waters, a substantial public health concern throughout the world, is typically identified by fecal indicator bacteria such as Escherichia coli. Thus, monitoring E. coli concentrations is critical to evaluate current conditions, determine restoration effectiveness, and inform model development and calibration. An often overlooked component of these monitoring and modeling activities is understanding the inherent random and systematic uncertainty present in measured data. In this research, a review and subsequent analysis was performed to identify, document, and analyze measurement uncertainty of E. coli data collected in stream flow and stormwater runoff as individual discrete samples or throughout a single runoff event. Data on the uncertainty contributed by sample collection, sample preservation/storage, and laboratory analysis in measured E. coli concentrations were compiled and analyzed, and differences in sampling method and data quality scenarios were compared. The analysis showed that: (1) manual integrated sampling produced the lowest random and systematic uncertainty in individual samples, but automated sampling typically produced the lowest uncertainty when sampling throughout runoff events; (2) sample collection procedures often contributed the highest amount of uncertainty, although laboratory analysis introduced substantial random uncertainty and preservation/storage introduced substantial systematic uncertainty under some scenarios; and (3) the uncertainty in measured E. coli concentrations was greater than that of sediment and nutrients, but the difference was not as great as may be assumed. This comprehensive analysis of uncertainty in E. coli concentrations measured in streamflow and runoff should provide valuable insight for designing E. coli monitoring projects, reducing uncertainty in quality assurance efforts, regulatory and policy decision making, and fate and transport modeling.

  12. Precise turnaround time measurement of laboratory processes using radiofrequency identification technology.

    PubMed

    Mayer, Horst; Brümmer, Jens; Brinkmann, Thomas

    2011-01-01

    To implement Lean Six Sigma in our central laboratory we conducted a project to measure single pre-analytical steps influencing turnaround time (TAT) of emergency department (ED) serum samples. The traditional approach of extracting data from the Laboratory Information System (LIS) for a retrospective calculation of a mean TAT is not suitable. Therefore, we used radiofrequency identification (RFID) chips for real time tracking of individual samples at any pre-analytical step. 1,200 serum tubes were labelled with RFID chips and were provided to the emergency department. 3 RFID receivers were installed in the laboratory: at the outlet of the pneumatic tube system, at the centrifuge, and in the analyser area. In addition, time stamps of sample entry at the automated sample distributor and communication of results from the analyser were collected from LIS. 1,023 labelled serum tubes arrived at our laboratory. 899 RFID tags were used for TAT calculation. The following transfer times were determined (median 95th percentile in min:sec): pneumatic tube system --> centrifuge (01:25/04:48), centrifuge --> sample distributor (14:06/5:33), sample distributor --> analysis system zone (02:39/15:07), analysis system zone --> result communication (12:42/22:21). Total TAT was calculated at 33:19/57:40 min:sec. Manual processes around centrifugation were identified as a major part of TAT with 44%/60% (median/95th percentile). RFID is a robust, easy to use, and error-free technology and not susceptible to interferences in the laboratory environment. With this study design we were able to measure significant variations in a single manual sample transfer process. We showed that TAT is mainly influenced by manual steps around the centrifugation process and we concluded that centrifugation should be integrated in solutions for total laboratory automation.

  13. A passive integrative sampler for mercury vapor in air and neutral mercury species in water

    USGS Publications Warehouse

    Brumbaugh, W.G.; Petty, J.D.; May, T.W.; Huckins, J.N.

    2000-01-01

    A passive integrative mercury sampler (PIMS) based on a sealed polymeric membrane was effective for the collection and preconcentration of Hg0. Because the Hg is both oxidized and stabilized in the PIMS, sampling intervals of weeks to months are possible. The effective air sampling rate for a 15 x 2.5 cm device was about 21-equivalents/day (0.002 m3/day) and the detection limit for 4-week sampling was about 2 ng/m3 for conventional ICP-MS determination without clean-room preparation. Sampling precision was ??? 5% RSD for laboratory exposures, and 5-10% RSD for field exposures. These results suggest that the PIMS could be useful for screening assessments of Hg contamination and exposure in the environment, the laboratory, and the workplace. The PIMS approach may be particularly useful for applications requiring unattended sampling for extended periods at remote locations. Preliminary results indicate that sampling for dissolved gaseous mercury (DGM) and potentially other neutral mercury species from water is also feasible. Rigorous validation of the sampler performance is currently in progress. (C) 1999 Elsevier Science Ltd.A passive integrative mercury sampler (PIMS) based on a sealed polymeric membrane was effective for the collection and preconcentration of Hg0. Because the Hg is both oxidized and stabilized in the PIMS, sampling intervals of weeks to months are possible. The effective air sampling rate for a 15??2.5 cm device was about 21-equivalents/day (0.002 m3/day) and the detection limit for 4-week sampling was about 2 ng/m3 for conventional ICP-MS determination without clean-room preparation. Sampling precision was ???5% RSD for laboratory exposures, and 5-10% RSD for field exposures. These results suggest that the PIMS could be useful for screening assessments of Hg contamination and exposure in the environment, the laboratory, and the workplace. The PIMS approach may be particularly useful for applications requiring unattended sampling for extended periods at remote locations. Preliminary results indicate that sampling for dissolved gaseous mercury (DGM) and potentially other neutral mercury species from water is also feasible. Rigorous validation of the sampler performance is currently in progress.

  14. Sampling and sample processing in pesticide residue analysis.

    PubMed

    Lehotay, Steven J; Cook, Jo Marie

    2015-05-13

    Proper sampling and sample processing in pesticide residue analysis of food and soil have always been essential to obtain accurate results, but the subject is becoming a greater concern as approximately 100 mg test portions are being analyzed with automated high-throughput analytical methods by agrochemical industry and contract laboratories. As global food trade and the importance of monitoring increase, the food industry and regulatory laboratories are also considering miniaturized high-throughput methods. In conjunction with a summary of the symposium "Residues in Food and Feed - Going from Macro to Micro: The Future of Sample Processing in Residue Analytical Methods" held at the 13th IUPAC International Congress of Pesticide Chemistry, this is an opportune time to review sampling theory and sample processing for pesticide residue analysis. If collected samples and test portions do not adequately represent the actual lot from which they came and provide meaningful results, then all costs, time, and efforts involved in implementing programs using sophisticated analytical instruments and techniques are wasted and can actually yield misleading results. This paper is designed to briefly review the often-neglected but crucial topic of sample collection and processing and put the issue into perspective for the future of pesticide residue analysis. It also emphasizes that analysts should demonstrate the validity of their sample processing approaches for the analytes/matrices of interest and encourages further studies on sampling and sample mass reduction to produce a test portion.

  15. Evacuated blood-collection tubes for haematological tests - a quality evaluation prior to their intended use for specimen collection.

    PubMed

    Gros, Nataša

    2013-05-01

    An inappropriate anticoagulant concentration in a blood sample can cause cell shrinkage and affect the haematocrit and mean corpuscular volume (MCV). In evacuated blood-collection tubes there are two parameters affecting the quality of the product: the anticoagulant amount introduced into the tube during its production and the internal under-pressure at the instant of the blood-specimen collection affecting the draw-volume. No testing procedures that would give an insight into the anticoagulant concentration that can be expected for blood samples after specimen collection have been available up until now. The methodology suggested here combines the draw-volume test performed with deionised water using a laboratory made measuring device, and a conductivity measurement. The corrections taking into account the air pressure and ambient temperature provide an insight into the anticoagulant concentration that can be expected for blood samples. Results presented in the form of a nomogram facilitate the routine use of the suggested methodology. Our 338-day study confirmed significant differences and variations in the quality and the anticoagulant concentrations of the K₃EDTA and K2EDTA tubes of different producers and identified different examples of non-compliance with the norms during the shelf life of the tubes. The quality evaluation of the evacuated blood-collection tubes prior to their intended use as suggested here can, in everyday laboratory practice, ensure that the tubes are used only if, and only until, their quality is adequate.

  16. National Survey of Adult and Pediatric Reference Intervals in Clinical Laboratories across Canada: A Report of the CSCC Working Group on Reference Interval Harmonization.

    PubMed

    Adeli, Khosrow; Higgins, Victoria; Seccombe, David; Collier, Christine P; Balion, Cynthia M; Cembrowski, George; Venner, Allison A; Shaw, Julie

    2017-11-01

    Reference intervals are widely used decision-making tools in laboratory medicine, serving as health-associated standards to interpret laboratory test results. Numerous studies have shown wide variation in reference intervals, even between laboratories using assays from the same manufacturer. Lack of consistency in either sample measurement or reference intervals across laboratories challenges the expectation of standardized patient care regardless of testing location. Here, we present data from a national survey conducted by the Canadian Society of Clinical Chemists (CSCC) Reference Interval Harmonization (hRI) Working Group that examines variation in laboratory reference sample measurements, as well as pediatric and adult reference intervals currently used in clinical practice across Canada. Data on reference intervals currently used by 37 laboratories were collected through a national survey to examine the variation in reference intervals for seven common laboratory tests. Additionally, 40 clinical laboratories participated in a baseline assessment by measuring six analytes in a reference sample. Of the seven analytes examined, alanine aminotransferase (ALT), alkaline phosphatase (ALP), and creatinine reference intervals were most variable. As expected, reference interval variation was more substantial in the pediatric population and varied between laboratories using the same instrumentation. Reference sample results differed between laboratories, particularly for ALT and free thyroxine (FT4). Reference interval variation was greater than test result variation for the majority of analytes. It is evident that there is a critical lack of harmonization in laboratory reference intervals, particularly for the pediatric population. Furthermore, the observed variation in reference intervals across instruments cannot be explained by the bias between the results obtained on instruments by different manufacturers. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  17. Customized laboratory information management system for a clinical and research leukemia cytogenetics laboratory.

    PubMed

    Bakshi, Sonal R; Shukla, Shilin N; Shah, Pankaj M

    2009-01-01

    We developed a Microsoft Access-based laboratory management system to facilitate database management of leukemia patients referred for cytogenetic tests in regards to karyotyping and fluorescence in situ hybridization (FISH). The database is custom-made for entry of patient data, clinical details, sample details, cytogenetics test results, and data mining for various ongoing research areas. A number of clinical research laboratoryrelated tasks are carried out faster using specific "queries." The tasks include tracking clinical progression of a particular patient for multiple visits, treatment response, morphological and cytogenetics response, survival time, automatic grouping of patient inclusion criteria in a research project, tracking various processing steps of samples, turn-around time, and revenue generated. Since 2005 we have collected of over 5,000 samples. The database is easily updated and is being adapted for various data maintenance and mining needs.

  18. Water-quality data from a sludge disposal test site, St. Petersburg, Florida, November 1973-July 1977

    USGS Publications Warehouse

    Fernandez, Mario

    1978-01-01

    From November 1973 to July 1977, water samples were collected from wells to identify background water-quality conditions and to determine the effects on ground-water quality by St. Petersburg 's sludge-disposal operation (sod farm). Specific conductance and pH were determined in the field. Samples were collected for laboratory determination of selected nitrogen and phosphorus species, sodium, potassium, calcium, magnesium, chloride, trace metals, chemical and biochemical oxygen demand, and coliforms. (Woodard-USGS)

  19. Molecular detection of airborne Coccidioides in Tucson, Arizona

    USGS Publications Warehouse

    Chow, Nancy A.; Griffin, Dale W.; Barker, Bridget M.; Loparev, Vladimir N.; Litvintseva, Anastasia P.

    2016-01-01

    Environmental surveillance of the soil-dwelling fungus Coccidioides is essential for the prevention of Valley fever, a disease primarily caused by inhalation of the arthroconidia. Methods for collecting and detectingCoccidioides in soil samples are currently in use by several laboratories; however, a method utilizing current air sampling technologies has not been formally demonstrated for the capture of airborne arthroconidia. In this study, we collected air/dust samples at two sites (Site A and Site B) in the endemic region of Tucson, Arizona, and tested a variety of air samplers and membrane matrices. We then employed a single-tube nested qPCR assay for molecular detection. At both sites, numerous soil samples (n = 10 at Site A and n = 24 at Site B) were collected and Coccidioides was detected in two samples (20%) at Site A and in eight samples (33%) at Site B. Of the 25 air/dust samples collected at both sites using five different air sampling methods, we detected Coccidioides in three samples from site B. All three samples were collected using a high-volume sampler with glass-fiber filters. In this report, we describe these methods and propose the use of these air sampling and molecular detection strategies for environmental surveillance of Coccidioides.

  20. Factors which contributed for low quality sputum smears for the detection of acid fast bacilli (AFB) at selected health centers in Ethiopia: A quality control perspective.

    PubMed

    Mekonen, Ayehu; Ayele, Yeshi; Berhan, Yifru; Woldeyohannes, Desalegn; Erku, Woldaregay; Sisay, Solomon

    2018-01-01

    Quality of tuberculosis (TB) microscopy diagnosis is not a guarantee despite implementation of External Quality Assurance (EQA) service in all laboratories of health facilities. Hence, we aimed at evaluating the technical quality and the findings of sputum smear microscopy for acid fast bacilli (AFB) at health centers in Hararge Zone, Oromia Region, Ethiopia. A cross-sectional study was carried out between July 8, 2014 and July 7, 2015.A pre-tested structured questionnaire was used to collect data. Lot Quality Assurance Sampling (LQAS) method was put into practice for collecting all necessary sample slides. Data were analyzed by using SPSS (Statistical Package for Social Sciences) version 20 software. P-value < 0.05 was considered as statistically significant. Of the total55 health center laboratories which had been assessed during the study period, 20 (36.4%) had major technical errors; 13 (23.6%) had 15 false negative results and 17 (30.9%) had 22 false positive results. Moreover, poor specimen quality, smear size, smear thickness, staining and evenness were indicated in 40 (72.7%), 39 (70.9%), 37 (67.3%), 27(49.1%) and 37 (67.3%) of the collected samples, respectively. False negative AFB findings were significantly associated with lack of Internal Quality Control (IQC) measures (AOR (Adjusted Odds Ratio): 2.90 (95% CI (Confidence Interval): 1.25,6.75) and poor staining procedures (AOR: 2.16(95% CI: 1.01, 5.11). The qualities of AFB smear microscopy reading and smearing were low in most of the laboratories of the health centers. Therefore, it is essential to strength EQA program through building the capacity of laboratory professionals.

  1. Considerations for estimating microbial environmental data concentrations collected from a field setting

    PubMed Central

    Silvestri, Erin E; Yund, Cynthia; Taft, Sarah; Bowling, Charlena Yoder; Chappie, Daniel; Garrahan, Kevin; Brady-Roberts, Eletha; Stone, Harry; Nichols, Tonya L

    2017-01-01

    In the event of an indoor release of an environmentally persistent microbial pathogen such as Bacillus anthracis, the potential for human exposure will be considered when remedial decisions are made. Microbial site characterization and clearance sampling data collected in the field might be used to estimate exposure. However, there are many challenges associated with estimating environmental concentrations of B. anthracis or other spore-forming organisms after such an event before being able to estimate exposure. These challenges include: (1) collecting environmental field samples that are adequate for the intended purpose, (2) conducting laboratory analyses and selecting the reporting format needed for the laboratory data, and (3) analyzing and interpreting the data using appropriate statistical techniques. This paper summarizes some key challenges faced in collecting, analyzing, and interpreting microbial field data from a contaminated site. Although the paper was written with considerations for B. anthracis contamination, it may also be applicable to other bacterial agents. It explores the implications and limitations of using field data for determining environmental concentrations both before and after decontamination. Several findings were of interest. First, to date, the only validated surface/sampling device combinations are swabs and sponge-sticks on stainless steel surfaces, thus limiting availability of quantitative analytical results which could be used for statistical analysis. Second, agreement needs to be reached with the analytical laboratory on the definition of the countable range and on reporting of data below the limit of quantitation. Finally, the distribution of the microbial field data and statistical methods needed for a particular data set could vary depending on these data that were collected, and guidance is needed on appropriate statistical software for handling microbial data. Further, research is needed to develop better methods to estimate human exposure from pathogens using environmental data collected from a field setting. PMID:26883476

  2. Specimen rejection in laboratory medicine: Necessary for patient safety?

    PubMed Central

    Dikmen, Zeliha Gunnur; Pinar, Asli; Akbiyik, Filiz

    2015-01-01

    Introduction The emergency laboratory in Hacettepe University Hospitals receives specimens from emergency departments (EDs), inpatient services and intensive care units (ICUs). The samples are accepted according to the rejection criteria of the laboratory. In this study, we aimed to evaluate the sample rejection ratios according to the types of pre-preanalytical errors and collection areas. Materials and methods The samples sent to the emergency laboratory were recorded during 12 months between January to December, 2013 in which 453,171 samples were received and 27,067 specimens were rejected. Results Rejection ratios was 2.5% for biochemistry tests, 3.2% for complete blood count (CBC), 9.8% for blood gases, 9.2% for urine analysis, 13.3% for coagulation tests, 12.8% for therapeutic drug monitoring, 3.5% for cardiac markers and 12% for hormone tests. The most frequent rejection reasons were fibrin clots (28%) and inadequate volume (9%) for biochemical tests. Clotted samples (35%) and inadequate volume (13%) were the major causes for coagulation tests, blood gas analyses and CBC. The ratio of rejected specimens was higher in the EDs (40%) compared to ICUs (30%) and inpatient services (28%). The highest rejection ratio was observed in neurology ICU (14%) among the ICUs and internal medicine inpatient service (10%) within inpatient clinics. Conclusions We detected an overall specimen rejection rate of 6% in emergency laboratory. By documentation of rejected samples and periodic training of healthcare personnel, we expect to decrease sample rejection ratios below 2%, improve total quality management of the emergency laboratory and promote patient safety. PMID:26527231

  3. Triangle area water supply monitoring project, October 1988 through September 2001, North Carolina -- description of the water-quality network, sampling and analysis methods, and quality-assurance practices

    USGS Publications Warehouse

    Oblinger, Carolyn J.

    2004-01-01

    The Triangle Area Water Supply Monitoring Project was initiated in October 1988 to provide long-term water-quality data for six area water-supply reservoirs and their tributaries. In addition, the project provides data that can be used to determine the effectiveness of large-scale changes in water-resource management practices, document differences in water quality among water-supply types (large multiuse reservoir, small reservoir, run-of-river), and tributary-loading and in-lake data for water-quality modeling of Falls and Jordan Lakes. By September 2001, the project had progressed in four phases and included as many as 34 sites (in 1991). Most sites were sampled and analyzed by the U.S. Geological Survey. Some sites were already a part of the North Carolina Division of Water Quality statewide ambient water-quality monitoring network and were sampled by the Division of Water Quality. The network has provided data on streamflow, physical properties, and concentrations of nutrients, major ions, metals, trace elements, chlorophyll, total organic carbon, suspended sediment, and selected synthetic organic compounds. Project quality-assurance activities include written procedures for sample collection, record management and archive, collection of field quality-control samples (blank samples and replicate samples), and monitoring the quality of field supplies. In addition to project quality-assurance activities, the quality of laboratory analyses was assessed through laboratory quality-assurance practices and an independent laboratory quality-control assessment provided by the U.S. Geological Survey Branch of Quality Systems through the Blind Inorganic Sample Project and the Organic Blind Sample Project.

  4. Contamination source review for Building E5485, Edgewood Area, Aberdeen Proving Ground, Maryland

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Billmark, K.A.; Hayes, D.C.; Draugelis, A.K.

    1995-09-01

    This report was prepared by Argonne National Laboratory (ANL) to document the results of a contamination source review of Building E5485 at the Aberdeen Proving Ground (APG) in Maryland. This report may be used to assist the US Army in planning for the future use or disposition of this building. The review included a historical records search, physical inspection, photographic documentation, geophysical investigation, and collection of air samples. Building E5485 (APG designation) is located in the drainage basin of the west branch of Canal Creek in the Edgewood Area of APG. The building was constructed in 1922 and used asmore » a fan house for agent operations in Building E5487 from 1925 to 1966. Building E5485 was then used as a laboratory to support manufacturing and storage of flammable agents and chemical warfare agents from 1966 until 1967, when it was placed on the inactive list. Air quality samples were collected upwind, downwind, and inside Building E5485 in November 1994. Analytical results showed no distinguishable difference in hydrocarbon and chlorinated solvent levels between the two background samples and the sample collected inside Building E5485. These results indicate that Building E5485 is not a source of volatile organic compound contamination.« less

  5. Comparison between active (pumped) and passive (diffusive) sampling methods for formaldehyde in pathology and histology laboratories.

    PubMed

    Lee, Eun Gyung; Magrm, Rana; Kusti, Mohannad; Kashon, Michael L; Guffey, Steven; Costas, Michelle M; Boykin, Carie J; Harper, Martin

    2017-01-01

    This study was to determine occupational exposures to formaldehyde and to compare concentrations of formaldehyde obtained by active and passive sampling methods. In one pathology and one histology laboratories, exposure measurements were collected with sets of active air samplers (Supelco LpDNPH tubes) and passive badges (ChemDisk Aldehyde Monitor 571). Sixty-six sample pairs (49 personal and 17 area) were collected and analyzed by NIOSH NMAM 2016 for active samples and OSHA Method 1007 (using the manufacturer's updated uptake rate) for passive samples. All active and passive 8-hr time-weighted average (TWA) measurements showed compliance with the OSHA permissible exposure limit (PEL-0.75 ppm) except for one passive measurement, whereas 78% for the active and 88% for the passive samples exceeded the NIOSH recommended exposure limit (REL-0.016 ppm). Overall, 73% of the passive samples showed higher concentrations than the active samples and a statistical test indicated disagreement between two methods for all data and for data without outliers. The OSHA Method cautions that passive samplers should not be used for sampling situations involving formalin solutions because of low concentration estimates in the presence of reaction products of formaldehyde and methanol (a formalin additive). However, this situation was not observed, perhaps because the formalin solutions used in these laboratories included much less methanol (3%) than those tested in the OSHA Method (up to 15%). The passive samplers in general overestimated concentrations compared to the active method, which is prudent for demonstrating compliance with an occupational exposure limit, but occasional large differences may be a result of collecting aerosolized droplets or splashes on the face of the samplers. In the situations examined in this study the passive sampler generally produces higher results than the active sampler so that a body of results from passive samplers demonstrating compliance with the OSHA PEL would be a valid conclusion. However, individual passive samples can show lower results than a paired active sampler so that a single result should be treated with caution.

  6. 24 CFR 35.1315 - Collection and laboratory analysis of samples.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint Hazard Evaluation and Hazard Reduction Activities § 35.1315...

  7. 24 CFR 35.1315 - Collection and laboratory analysis of samples.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint Hazard Evaluation and Hazard Reduction Activities § 35.1315...

  8. 24 CFR 35.1315 - Collection and laboratory analysis of samples.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint Hazard Evaluation and Hazard Reduction Activities § 35.1315...

  9. 24 CFR 35.1315 - Collection and laboratory analysis of samples.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint Hazard Evaluation and Hazard Reduction Activities § 35.1315...

  10. 24 CFR 35.1315 - Collection and laboratory analysis of samples.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint Hazard Evaluation and Hazard Reduction Activities § 35.1315...

  11. Quality-assurance design applied to an assessment of agricultural pesticides in ground water from carbonate bedrock aquifers in the Great Valley of eastern Pennsylvania

    USGS Publications Warehouse

    Breen, Kevin J.

    2000-01-01

    Assessments to determine whether agricultural pesticides are present in ground water are performed by the Commonwealth of Pennsylvania under the aquifer monitoring provisions of the State Pesticides and Ground Water Strategy. Pennsylvania's Department of Agriculture conducts the monitoring and collects samples; the Department of Environmental Protection (PaDEP) Laboratory analyzes the samples to measure pesticide concentration. To evaluate the quality of the measurements of pesticide concentration for a groundwater assessment, a quality-assurance design was developed and applied to a selected assessment area in Pennsylvania. This report describes the quality-assurance design, describes how and where the design was applied, describes procedures used to collect and analyze samples and to evaluate the results, and summarizes the quality assurance results along with the assessment results.The design was applied in an agricultural area of the Delaware River Basin in Berks, Lebanon, Lehigh, and Northampton Counties to evaluate the bias and variability in laboratory results for pesticides. The design—with random spatial and temporal components—included four data-quality objectives for bias and variability. The spatial design was primary and represented an area comprising 30 sampling cells. A quality-assurance sampling frequency of 20 percent of cells was selected to ensure a sample number of five or more for analysis. Quality-control samples included blanks, spikes, and replicates of laboratory water and spikes, replicates, and 2-lab splits of groundwater. Two analytical laboratories, the PaDEP Laboratory and a U.S. Geological Survey Laboratory, were part of the design. Bias and variability were evaluated by use of data collected from October 1997 through January 1998 for alachlor, atrazine, cyanazine, metolachlor, simazine, pendimethalin, metribuzin, and chlorpyrifos.Results of analyses of field blanks indicate that collection, processing, transport, and laboratory analysis procedures did not contaminate the samples; there were no false-positive results. Pesticides were detected in water when pesticides were spiked into (added to) samples. There were no false negatives for the eight pesticides in all spiked samples. Negative bias was characteristic of analytical results for the eight pesticides, and bias was generally in excess of 10 percent from the ‘true’ or expected concentration (34 of 39 analyses, or 87 percent of the ground-water results) for pesticide concentrations ranging from 0.31 to 0.51 mg/L (micrograms per liter). The magnitude of the negative bias for the eight pesticides, with the exception of cyanazine, would result in reported concentrations commonly 75-80 percent of the expected concentration in the water sample. The bias for cyanazine was negative and within 10 percent of the expected concentration. A comparison of spiked pesticide-concentration recoveries in laboratory water and ground water indicated no effect of the ground-water matrix, and matrix interference was not a source of the negative bias. Results for the laboratory-water spikes submitted in triplicate showed large variability for recoveries of atrazine, cyanazine, and pendimethalin. The relative standard deviation (RSD) was used as a measure of method variability over the course of the study for laboratory waters at a concentration of 0.4 mg/L. An RSD of about 11 percent (or about ?0.05 mg/L)characterizes the method results for alachlor, chlorpyrifos, metolachlor, metribuzin, and simazine. Atrazine and pendimethalin have RSD values of about 17 and 23 percent, respectively. Cyanazine showed the largest RSD at nearly 51 percent. The pesticides with low variability in laboratory-water spikes also had low variability in ground water.The assessment results showed that atrazinewas the most commonly detected pesticide in ground water in the assessment area. Atrazine was detected in water from 22 of the 28 wells sampled, and recovery results for atrazine were some of the worst (largest negative bias). Concentrations of the eight pesticides in ground water from wells were generally less than 0.3 µg/L. Only six individual measurements of the concentrations in water from six of the wells were at or above 0.3 µg/L, five for atrazine and one for metolachlor. There were eight additional detections of metolachlor and simazine at concentrations less than 0.1 µg/L. No well water contained more than one pesticide at concentra-tions at or above 0.3 µg/L. Evidence exists, how-ever, for a pattern of co-occurrence of metolachlor and simazine at low concentrations with higher concentrations of atrazine.Large variability in replicate samples and negative bias for pesticide recovery from spiked samples indicate the need to use data for pesticide recovery in the interpretation of measured pesti-cide concentrations in ground water. Data from samples spiked with known amounts of pesticides were a critical component of a quality-assurance design for the monitoring component of the Pesti-cides and Ground Water Strategy.Trigger concentrations, the concentrations that require action under the Pesticides and Ground Water Strategy, should be considered maximums for action. This consideration is needed because of the magnitude of negative bias.

  12. Turnaround Time for Early Infant HIV Diagnosis in Rural Zambia: A Chart Review

    PubMed Central

    Sutcliffe, Catherine G.; van Dijk, Janneke H.; Hamangaba, Francis; Mayani, Felix; Moss, William J.

    2014-01-01

    Background Early infant HIV diagnosis is challenging in sub-Saharan Africa, particularly in rural areas where laboratory capacity is limited. Specimens must be transported to central laboratories for testing, leading to delays in diagnosis and initiation of antiretroviral therapy. This study was undertaken in rural Zambia to measure the turnaround time for confirmation of HIV infection and identify delays in diagnosis. Methods Chart reviews were conducted from 2010–2012 for children undergoing early infant HIV diagnosis at Macha Hospital in Zambia. Relevant dates, receipt of drugs by mother and child for the prevention of mother-to-child transmission (PMTCT), and test results were abstracted. Results 403 infants provided 476 samples for early infant diagnosis. The median age at the “6-week” and “6-month” assessments was 8.1 weeks and 7.0 months, respectively. The majority of mothers (80%) and infants (67%) received PMTCT. The median time between sample collection and arrival at the central laboratory in Lusaka was 17 days (IQR: 10, 28); arrival at the central laboratory to testing was 6 days (IQR: 5, 11); testing to return of results to the clinic was 29 days (IQR: 17, 36); arrival of results at the clinic to return of results to the caregiver was 45 days (IQR: 24, 79). The total median time from sample collection to return of results to the caregiver was 92 days (IQR: 84, 145). The proportion of HIV PCR positive samples was 12%. The total median turnaround time was shorter for HIV PCR positive as compared to negative or invalid samples (85 vs. 92 days; p = 0.08). Conclusions Delays in processing and communicating test results were identified, particularly in returning results from the central laboratory to the clinic and from the clinic to the caregiver. A more efficient process is needed so that caregivers can be provided test results more rapidly, potentially resulting in earlier treatment initiation and better outcomes for HIV-infected infants. PMID:24475214

  13. Method of Analysis by the U.S. Geological Survey California District Sacramento Laboratory-- Determination of Dissolved Organic Carbon in Water by High Temperature Catalytic Oxidation, Method Validation, and Quality-Control Practices

    USGS Publications Warehouse

    Bird, Susan M.; Fram, Miranda S.; Crepeau, Kathryn L.

    2003-01-01

    An analytical method has been developed for the determination of dissolved organic carbon concentration in water samples. This method includes the results of the tests used to validate the method and the quality-control practices used for dissolved organic carbon analysis. Prior to analysis, water samples are filtered to remove suspended particulate matter. A Shimadzu TOC-5000A Total Organic Carbon Analyzer in the nonpurgeable organic carbon mode is used to analyze the samples by high temperature catalytic oxidation. The analysis usually is completed within 48 hours of sample collection. The laboratory reporting level is 0.22 milligrams per liter.

  14. Stable carbon isotope ratio in atmospheric CO2 collected by new diffusive devices.

    PubMed

    Proto, Antonio; Cucciniello, Raffaele; Rossi, Federico; Motta, Oriana

    2014-02-01

    In this paper, stable carbon isotope ratios (δ (13)C) were determined in the atmosphere by using a Ca-based sorbent, CaO/Ca12Al14O33 75:25 w/w, for passively collecting atmospheric CO2, in both field and laboratory experiments. Field measurements were conducted in three environments characterized by different carbon dioxide sources. In particular, the environments under consideration were a rather heavily trafficked road, where the source of CO2 is mostly vehicle exhaust, a rural unpolluted area, and a private kitchen where the major source of CO2 was gas combustion. Samplers were exposed to the free atmosphere for 3 days in order to allow collection of sufficient CO2 for δ(13)C analysis, then the collected CO2 was desorbed from the adsorbent with acid treatment, and directly analyzed by nondispersive infrared (NDIR) instrument. δ (13)C results confirmed that the samplers collected representative CO2 samples and no fractionation occurred during passive trapping, as also confirmed by an appositely designed experiment conducted in the laboratory. Passive sampling using CaO/Ca12Al14O33 75:25 w/w proved to be an easy and reliable method to collect atmospheric carbon dioxide for δ (13)C analysis in both indoor and outdoor places.

  15. Guidelines for quality assurance and quality control of fish taxonomic data collected as part of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Walsh, Stephen Joseph; Meador, Michael R.

    1998-01-01

    Fish community structure is characterized by the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) Program as part of a perennial, multidisciplinary approach to evaluating the physical, chemical, and biological conditions of the Nation's water resources. The objective of quality assurance and quality control of fish taxonomic data that are collected as part of the NAWQA Program is to establish uniform guidelines and protocols for the identification, processing, and archiving of fish specimens to ensure that accurate and reliable data are collected. Study unit biologists, collaborating with regional biologists and fish taxonomic specialists, prepare a pre-sampling study plan that includes a preliminary faunal list and identification of an ichthyological curation center for receiving preserved fish specimens. Problematic taxonomic issues and protected taxa also are identified in the study plan, and collecting permits are obtained in advance of sampling activities. Taxonomic specialists are selected to identify fish specimens in the field and to assist in determining what fish specimens should be sacrificed, fixed, and preserved for laboratory identification, independent taxonomic verification, and long-term storage in reference or voucher collections. Quantitative and qualitative sampling of fishes follows standard methods previously established for the NAWQA Program. Common ichthyological techniques are used to process samples in the field and prepare fish specimens to be returned to the laboratory or sent to an institutional repository. Taxonomic identifications are reported by using a standardized list of scientific names that provides nomenclatural consistency and uniformity across study units.

  16. OPTIMIZING BTEX BIODEGRADATION UNDER DENITRIFYING CONDITIONS

    EPA Science Inventory

    Laboratory tests were conducted to determine optimum conditions for benzene, toluene, ethylbenzene, and xylene (collectively known as BTEX) biodegradation by aquifer microorganisms under denitrifying conditions. Microcosms, constructed with aquifer samples from Traverse City, Mic...

  17. Soil/sediment characterization for 216-A-29 ditch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitchell, R.M.

    1997-03-01

    This document provides a detailed description of the environmental samples collected from the 216-A-29 Ditch in 1988. Tables summarizing the laboratory data for radionuclides, metals, and soil chemistry are included.

  18. Annual Report: 2011-2012 Storm Season Sampling, Non-Dry Dock Stormwater Monitoring for Puget Sound Naval Shipyard, Bremerton, WA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brandenberger, Jill M.; Metallo, David; Rupert, Brian

    2013-07-03

    Annual PSNS non-dry dock storm water monitoring results for 2011-2012 storm season. Included are a brief description of the sampling procedures, storm event information, laboratory methods and data collection, a results and discussion section, and the conclusions and recommendations.

  19. Genetic variability of spined soldier bugs (Hemiptera: Pentatomidae) sampled from distinct field sites and laboratory colonies in the United States

    USDA-ARS?s Scientific Manuscript database

    The spined soldier bug, Podisus maculiventris (Say), is an important biological control agent for agricultural and forest pests that preys on eggs and larvae of lepidopteran and coleopteran species. Genetic variability among field collected samples from Michigan, Mississippi, Missouri, and Florida, ...

  20. In situ assay of nitrate reductase activity using portable water bath

    Treesearch

    Adam Rajsz; Bronisław Wojtuń; Andrzej Bytnerowicz

    2017-01-01

    In environmental research (i.e., plant ecophysiology, environmental microbiology, and environmental chemistry), some assays require incubation of samples at controlled temperature and darkness. Until now, due to a lack of equipment providing such possibility in situ, researchers had to move collected samples to the laboratory for incubation. Obviously, a delayed...

  1. Recovery and Stability of Δ9-Tetrahydrocannabinol Using the Oral-Eze® Oral Fluid Collection System and Intercept® Oral Specimen Collection Device.

    PubMed

    Samano, Kimberly L; Anne, Lakshmi; Johnson, Ted; Tang, Kenneth; Sample, R H Barry

    2015-10-01

    Oral fluid (OF) is increasingly used for clinical, forensic and workplace drug testing as an alternative to urine. Uncertainties surrounding OF collection device performance, drug stability and testing reproducibility may be partially responsible for delays in the implementation of OF testing in regulated drug testing programs. Stability of Δ(9)-tetrahydrocannabinol (THC) fortified and authentic specimens was examined after routine collection, transport and laboratory testing. Acceptable recovery and stability were observed when THC-fortified OF (1.5 and 4.5 ng/mL) was applied to Oral-Eze devices. Neat OF samples collected with Oral-Eze, processed per the package insert, and fortified with THC (3 and 6 ng/mL) were stable (±20%) at room temperature (21-25°C), refrigerated (2-8°C) and frozen (-25 to -15°C) conditions up to 1 month, while samples collected with Intercept devices showed decreases at refrigerated and room temperatures. After long-term refrigerated or frozen storage, maximum reductions in THC concentrations were 42% for Oral-Eze and 69% for Intercept. After ≥1 year frozen storage, 80.7% of laboratory specimens positive for THC (3 ng/mL cut-off) by GC-MS were reconfirmed positive (within 25%), with an average THC decrease of 4.2%. Specimens (n = 47) processed with Oral-Eze (diluted) and tested via enzyme immunoassay were concordant with LC-MS-MS results and showed 100% sensitivity and 95% specificity. Paired specimens collected with Oral-Eze and Intercept exhibited 98% overall agreement between the immunoassay test systems. Collectively, these data demonstrate consistent and reproducible recovery and stability of THC in OF after collection, transport and laboratory testing using the Oral-Eze OF Collection System. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Evaluation of volatile organic compound (VOC) blank data and application of study reporting levels to groundwater data collected for the California GAMA Priority Basin Project, May 2004 through September 2010

    USGS Publications Warehouse

    Fram, Miranda S.; Olsen, Lisa D.; Belitz, Kenneth

    2012-01-01

    Volatile organic compounds (VOCs) were analyzed in quality-control samples collected for the California Groundwater Ambient Monitoring and Assessment (GAMA) Program Priority Basin Project. From May 2004 through September 2010, a total of 2,026 groundwater samples, 211 field blanks, and 109 source-solution blanks were collected and analyzed for concentrations of 85 VOCs. Results from analyses of these field and source-solution blanks and of 2,411 laboratory instrument blanks during the same time period were used to assess the quality of data for the 2,026 groundwater samples. Eighteen VOCs were detected in field blanks or source-solution blanks: acetone, benzene, bromodichloromethane, 2-butanone, carbon disulfide, chloroform, 1,1-dichloroethene, dichloromethane, ethylbenzene, tetrachloroethene, styrene, tetrahydrofuran, toluene, trichloroethene, trichlorofluoromethane, 1,2,4-trimethylbenzene, m- and p-xylenes, and o-xylene. The objective of the evaluation of the VOC-blank data was to determine if study reporting levels (SRLs) were needed for any of the VOCs detected in blanks to ensure the quality of the data from groundwater samples. An SRL is equivalent to a raised reporting level that is used in place of the reporting level used by the analyzing laboratory [long‑term method detection level (LT-MDL) or laboratory reporting level (LRL)] to reduce the probability of reporting false-positive detections. Evaluation of VOC-blank data was done in three stages: (1) identification of a set of representative quality‑control field blanks (QCFBs) to be used for calculation of SRLs and identification of VOCs amenable to the SRL approach, (2) evaluation of potential sources of contamination to blanks and groundwater samples by VOCs detected in field blanks, and (3) selection of appropriate SRLs from among four potential SRLs for VOCs detected in field blanks and application of those SRLs to the groundwater data. An important conclusion from this study is that to ensure the quality of the data from groundwater samples, it was necessary to apply different methods of determining SRLs from field blank data to different VOCs, rather than use the same method for all VOCs. Four potential SRL values were defined by using three approaches: two values were defined by using a binomial probability method based on one-sided, nonparametric upper confidence limits, one was defined as equal to the maximum concentration detected in the field blanks, and one was defined as equal to the maximum laboratory method detection level used during the period when samples were collected for the project. The differences in detection frequencies and concentrations among different types of blanks (laboratory instrument blanks, source-solution blanks, and field blanks collected with three different sampling equipment configurations) and groundwater samples were used to infer the sources and mechanisms of contamination for each VOC detection in field blanks. Other chemical data for the groundwater samples (oxidation-reduction state, co-occurrence of VOCs, groundwater age) and ancillary information about the well sites (land use, presence of known sources of contamination) were used to evaluate whether the patterns of detections of VOCs in groundwater samples before and after application of potential SRLs were plausible. On this basis, the appropriate SRL was selected for each VOC that was determined to require an SRL. The SRLs for ethylbenzene [0.06 microgram per liter (μg/L)], m- and p-xylenes (0.33 μg/L), o-xylene (0.12 μg/L), toluene (0.69 μg/L), and 1,2,4-trimethylbenzene (0.56 μg/L) corresponded to the highest concentrations detected in the QCFBs and were selected because they resulted in the most censoring of groundwater data. Comparisons of hydrocarbon ratios in groundwater samples and blanks and comparisons between detection frequencies of the five hydrocarbons in groundwater samples and different types of blanks suggested three dominant sources of contamination that affected groundwater samples and blanks: (1) ethylbenzene, m- and p-xylenes, o-xylene, and toluene from fuel or exhaust components sorbed onto sampling lines, (2) toluene from vials and the source blank water, and (3) 1,2,4-trimethylbenzene from materials used for collection of samples for radon-222 analysis.

  3. Occurrence and concentrations of selected trace elements and halogenated organic compounds in stream sediments and potential sources of polychlorinated biphenyls, Leon Creek, San Antonio, Texas, 2012–14

    USGS Publications Warehouse

    Wilson, Jennifer T.

    2016-06-23

    Sediment samples collected from Leon Creek by the USGS during 2007–9 and 2012–14 at a total of eight sites following identical field and laboratory methods were evaluated to determine if potential PCB sources could be identified. Total PCB concentrations in the sediment samples collected upstream from the Joint Base site were low or nondetections; while concentrations in the samples collected on and downstream from the Joint Base site were greater. Congeners 180 and 138 constituted the greatest proportion of the PCB mixture in samples collected upstream from, on, and downstream from the Joint Base site. Upstream from the Joint Base site, congeners 180 and 138 constituted 50 percent and 35 percent respectively of the PCBs congeners found in the samples. On and downstream from the Joint Base site, congeners 180 and 138 constituted 80 percent and 13 percent respectively of the PCBs congeners found in the samples. Chi-square (C2) tests also indicate that samples collected from the Loop 410 site were statistically different from samples collected from the Joint Base site and sites downstream. The PCB congener pattern in the Leon Creek samples is most like the congener mixture in Aroclor 1260, which is chemically similar to the PCBs detected in the fish samples that resulted in the 2003 fish consumption advisory.

  4. Holding effects on coliform enumeration in drinking water samples.

    PubMed Central

    McDaniels, A E; Bordner, R H; Gartside, P S; Haines, J R; Brenner, K P; Rankin, C C

    1985-01-01

    Standard procedures for analyzing drinking water stress the need to adhere to the time and temperature conditions recommended for holding samples collected for microbiological testing. The National Drinking Water Laboratory Certification Program requires compliance with these holding limits, but some investigators have reported difficulties in meeting them. Research was conducted by standard analytical methods to determine if changes occurred when samples were held at 5 and 22 degrees C and analyzed at 0, 24, 30, and 48 h. Samples were analyzed for coliforms by the membrane filter and fermentation-tube procedures and for heterotrophs by the pour plate method. A total of 17 treated water samples were collected from a large municipal distribution system from August to December 1981, and 12 samples were collected from January to May 1983. The samples were dosed with coliforms previously isolated from the water system, Enterobacter cloacae in 1981 and Citrobacter freundii in 1983. The coliform counts declined linearly over time, and the rates of decline were significant at both 5 and 22 degrees C. Within 24 h at 22 degrees C, levels of E. cloacae and C. freundii decreased by 47 and 26%, respectively, and at 5 degrees C, E. cloacae numbers declined by 23%. Results from these representative laboratory-grown coliforms reinforced those previously obtained with naturally occurring coliforms under the same experimental conditions. Significantly, some samples with initially unacceptable counts (greater than 4/100 ml) met the safe drinking water limits after storage at 24 h at 5 and 22 degrees C and would have been classified as satisfactory.(ABSTRACT TRUNCATED AT 250 WORDS) Images PMID:4083877

  5. Usefulness of laboratory methods in diagnosis of pertussis in adult with paroxysmal cough.

    PubMed

    Piekarska, Katarzyna; Rzeczkowska, Magdalena; Rastawicki, Waldemar; Dąbrowska-Iwanicka, Anna; Paradowska-Stankiewicz, Iwona

    2014-01-01

    Pertussis is an acute, highly contagious bacterial infection of respiratory system caused by Bordetella pertussis. Principally, disease affects young children, however, recently it is also reported in adolescents and adults. Symptoms of pertussis in adults are non-specific, i.e. dry, paroxysmal and protracted cough. Thus, it is rarely diagnosed in this group. This paper aimed at evaluating the usefulness of the laboratory methods in diagnosis of pertussis in adults based on a case presenting with dry, paroxysmal and chronic cough. Sputum (collected on 25th January 2013) and paired serum samples (collected on 13th February and 19 April 2013) were tested. Pertussis diagnostics involved culture, in-house PCR, real-time PCR and ELISA. Sputum culture, using commercial medium Bordetella Selective Medium by Oxoid did not reveal the presence of B. pertussis. Real-time PCR and PCR, however, confirmed the presence of insertion sequence IS481 and pertussis toxin promoter sequence ptx-Pr, markers indicative of B. pertussis infection. Serological testing revealed the high titres of IgA, IgG and IgM antibodies to B. pertussis in the first sample. In the second sample, collected 2 months following the first one, a significant decrease in IgA antibodies was reported. These data suggest a high usefulness of the laboratory methods in the diagnosis of pertussis in adults with chronic cough. Application of such methods ensures adequate diagnosis of disease, quick introduction of proper treatment and implementation of procedures preventing the spread of infection.

  6. INNOVATIVE TECHNOLOGY VERIFICATION REPORT " ...

    EPA Pesticide Factsheets

    The Synchronous Scanning Luminoscope (Luminoscope) developed by the Oak Ridge National Laboratory in collaboration with Environmental Systems Corporation (ESC) was demonstrated under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation Program in June 2000 at the Navy Base Ventura County site in Port Hueneme, California. The purpose of the demonstration was to collect reliable performance and cost data for the Luminoscope and six other field measurement devices for total petroleum hydrocarbons (TPH) in soil. In addition to assessing ease of device operation, the key objectives of the demonstration included determining the (1) method detection limit, (2) accuracy and precision, (3) effects of interferents and soil moisture content on TPH measurement, (4) sample throughput, and (5) TPH measurement costs for each device. The demonstration involved analysis of both performance evaluation samples and environmental samples collected in five areas contaminated with gasoline, diesel, lubricating oil, or other petroleum products. The performance and cost results for a given field measurement device were compared to those for an off-site laboratory reference method,

  7. Evaluation of nutrient quality-assurance data for Alexanders and Mount Rock Spring basins, Cumberland County, Pennsylvania

    USGS Publications Warehouse

    Witt, E. C.; Hippe, D.J.; Giovannitti, R.M.

    1992-01-01

    A total of 304 nutrient samples were collected from May 1990 through September 1991 to determine concentrations and loads of nutrients in water discharged from two spring basins in Cumberland County, Pa. Fifty-four percent of these nutrient samples were for the evaluation of (1) laboratory consistency, (2) container and preservative cleanliness, (3) maintenance of analyte representativeness as affected by three different preservation methods, and (4) comparison of analyte results with the "Most Probable Value" for Standard Reference Water Samples. Results of 37 duplicate analyses indicate that the Pennsylvania Department of Environmental Resources, Bureau of Laboratories (principal laboratory) remained within its ±10 percent goal for all but one analyte. Results of the blank analysis show that the sampling containers did not compromise the water quality. However, mercuric-chloride-preservation blanks apparently contained measurable ammonium in four of five samples and ammonium plus organic nitrogen in two of five samples. Interlaboratory results indicate substantial differences in the determination of nitrate and ammonium plus organic nitrogen between the principal laboratory and the U.S. Geological Survey National Water-Quality Laboratory. In comparison with the U.S. Environmental Protection Agency Quality-Control Samples, the principal laboratory was sufficiently accurate in its determination of nutrient anafytes. Analysis of replicate samples indicated that sulfuric-acid preservative best maintained the representativeness of the anafytes nitrate and ammonium plus organic nitrogen, whereas, mercuric chloride best maintained the representativeness of orthophosphate. Comparison of nutrient analyte determinations with the Most Probable Value for each preservation method shows that two of five analytes with no chemical preservative compare well, three of five with mercuric-chloride preservative compare well, and three of five with sulfuricacid preservative compare well.

  8. Serological evidence for hepatitis e virus infection in laboratory monkeys and pigs in animal facilities in Japan.

    PubMed

    Yamamoto, Hiroshi; Li, Tian-Cheng; Koshimoto, Chihiro; Ito, Kaori; Kita, Masakazu; Miyashita, Nobumoto; Arikawa, Jiro; Yagami, Kenichi; Asano, Masahide; Tezuka, Hideo; Suzuki, Noboru; Kurosawa, Tsutomu; Shibahara, Toshiyuki; Furuya, Masato; Mohri, Shirou; Sato, Hiroshi; Ohsawa, Kazutaka; Ibuki, Kentaro; Takeda, Naokazu

    2008-07-01

    In laboratory animal facilities, monkeys and pigs are used for animal experiments, but the details of hepatitis E virus (HEV) infection in these animals are unknown. The risk of infection from laboratory animals to humans has become a concern; therefore, much attention should be paid to the handling of these animals during their care and use, including surgical procedures performed on infected animals. In this connection, serum samples collected from 916 monkeys and 77 pigs kept in 23 animal facilities belonging to the Japanese Association of Laboratory Animal Facilities of National University Corporations (JALAN) and the Japanese Association of Laboratory Animal Facilities of Public and Private Universities (JALAP) in Japan were examined for the purpose of detecting antibodies to HEV and HEV RNA by using ELISA and RT-PCR, respectively. One hundred and seven serum samples of 916 (11.7%) monkeys were positive for anti-HEV IgG, and 7 and 17 serum samples of 916 (0.8% and 5.3%) monkeys were positive for anti-HEV IgM and IgA, respectively. Thirty-six samples from 62 (58.1%) farm pigs were positive for anti-HEV IgG, whereas all samples tested from miniature pigs were negative (0/15, 0%). Seven samples from 62 (9.1%) farm pigs and 7 samples from 916 (0.8%) monkeys were positive for IgM antibody, but these HEV-IgM antibody positive serum samples were HEV-RNA negative by RT-PCR. The IgM antibody positive rate (9.1%) of farm pigs was much higher than that of monkeys (0.8%). These results suggest the relative levels of risk of HEV infection from these animals to animal handlers and researchers who work with them in laboratory animal facilities.

  9. Biobanking of different body fluids within the frame of IVF-a standard operating procedure to improve reproductive biology research.

    PubMed

    Schenk, Michael; Huppertz, Berthold; Obermayer-Pietsch, Barbara; Kastelic, Darja; Hörmann-Kröpfl, Martina; Weiss, Gregor

    2017-02-01

    The aim of the present study was to develop a standard operating procedure (SOP) for the collection, transport, and storage of human cumulus cells, follicular fluid, blood serum, seminal plasma, embryo culture supernatant, and embryo culture supernatant control obtained within the IVF process under approved protocols and written informed consent from participating patients. The SOP was developed at the Kinderwunsch Institut Schenk, Dobl, Austria, together with Biobank Graz of the Medical University of Graz, Austria. The SOP provides comprehensive details of laboratory procedures and sampling of the different fluids within the IVF process. Furthermore, information on sample coding, references of involved laboratory techniques (e.g., oocyte retrieval with a Steiner-TAN needle), ethical approvals, and biobanking procedures are presented. The result of the present study is a standard operating procedure. The SOP ensures a professional way for collection and scientific use of IVF samples by the Kinderwunsch Institut Schenk, Dobl, Austria, and Biobank Graz of the Medical University of Graz, Austria. It can be used as a template for other institutions to unify specimen collection procedures in the field of reproductive health research.

  10. Detection of Poliovirus Circulation by Environmental Surveillance in the Absence of Clinical Cases in Israel and the Palestinian Authority

    PubMed Central

    Manor, Y.; Handsher, R.; Halmut, T.; Neuman, M.; Bobrov, A.; Rudich, H.; Vonsover, A.; Shulman, L.; Kew, O.; Mendelson, E.

    1999-01-01

    The global eradication of poliomyelitis, believed to be achievable around the year 2000, relies on strategies which include high routine immunization coverage and mass vaccination campaigns, along with continuous monitoring of wild-type virus circulation by using the laboratory-based acute flaccid paralysis (AFP) surveillance. Israel and the Palestinian Authority are located in a geographical region in which poliovirus is still endemic but have been free of poliomyelitis since 1988 as a result of intensive immunization programs and mass vaccination campaigns. To monitor the wild-type virus circulation, environmental surveillance of sewage samples collected monthly from 25 to 30 sites across the country was implemented in 1989 and AFP surveillance began in 1994. The sewage samples were processed in the laboratory with a double-selective tissue culture system, which enabled economical processing of large number of samples. Between 1989 and 1997, 2,294 samples were processed, and wild-type poliovirus was isolated from 17 of them in four clusters, termed “silent outbreaks,” in September 1990 (type 3), between May and September 1991 (type 1), between October 1994 and June 1995 (type 1), and in December 1996 (type 1). Fifteen of the 17 positive samples were collected in the Gaza Strip, 1 was collected in the West Bank, and 1 was collected in the Israeli city of Ashdod, located close to the Gaza Strip. The AFP surveillance system failed to detect the circulating wild-type viruses. These findings further emphasize the important role that environmental surveillance can play in monitoring the eradication of polioviruses. PMID:10325305

  11. Effects of fecal sampling on preanalytical and analytical phases in quantitative fecal immunochemical tests for hemoglobin.

    PubMed

    Rapi, Stefano; Berardi, Margherita; Cellai, Filippo; Ciattini, Samuele; Chelazzi, Laura; Ognibene, Agostino; Rubeca, Tiziana

    2017-07-24

    Information on preanalytical variability is mandatory to bring laboratories up to ISO 15189 requirements. Fecal sampling is greatly affected by lack of harmonization in laboratory medicine. The aims of this study were to obtain information on the devices used for fecal sampling and to explore the effect of different amounts of feces on the results from the fecal immunochemical test for hemoglobin (FIT-Hb). Four commercial sample collection devices for quantitative FIT-Hb measurements were investigated. The volume of interest (VOI) of the probes was measured from diameter and geometry. Quantitative measurements of the mass of feces were carried out by gravimetry. The effects of an increased amount of feces on the analytical environment were investigated measuring the Hb values with a single analytical method. VOI was 8.22, 7.1 and 9.44 mm3 for probes that collected a target of 10 mg of feces, and 3.08 mm3 for one probe that targeted 2 mg of feces. The ratio between recovered and target amounts of devices ranged from 56% to 121%. Different changes in the measured Hb values were observed, in adding increasing amounts of feces in commercial buffers. The amounts of collected materials are related to the design of probes. Three out 4 manufacturers declare the same target amount using different sampling volumes and obtaining different amounts of collected materials. The introduction of a standard probes to reduce preanalytical variability could be an useful step for fecal test harmonization and to fulfill the ISO 15189 requirements.

  12. 75 FR 63849 - Proposed Information Collection; OMB Control Number 1018-0078; Injurious Wildlife; Importation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-18

    ... Certification for Live Fish and Fish Eggs AGENCY: Fish and Wildlife Service, Interior. ACTION: Notice; request... recent certification. Number, life stage, and species of animals or eggs. Site and date of sample collection. Name and address of laboratory conducting the assays. Site from which the animals or eggs will be...

  13. Operational Toxicology Research

    DTIC Science & Technology

    2006-08-01

    Activity Relationships CQSARs) assessments of Air Force chemicals. Assay samples Completed collected for biochemical and molecular endpoints and...techniques for perchlorate in water, groundwater, soil and biological matrices such as blood, urine , milk. thyroid and other tissues required for...in vivo laboratory animal experiments with a l710D70ll Toxicological Response in Urine Using variety of known target organ toxicants, collect urine

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Virginia Finley; Sheneman, Robert S.; Levine, Jerry D.

    Contained in the following report are data for radioactivity in the environment collected and analyzed by Princeton Plasma Physics Laboratory’s Princeton Environmental, Analytical, and Radiological Laboratory (PEARL). The PEARL is located on-site and is certified for analyzing radiological and non-radiological parameters through the New Jersey Department of Environmental Protection’s Laboratory Certification Program, Certification Number 12471. Non-radiological surface and ground water samples are analyzed by NJDEP certified subcontractor laboratories – QC, Inc. and Accutest Laboratory. To the best of our knowledge, these data, as contained in the “Annual Site Environmental Report for 2011,” are documented and certified to be correct.

  15. Inter-laboratory exercise on antibiotic drugs analysis in aqueous samples.

    PubMed

    Roig, B; Brogat, M; Mompelat, S; Leveque, J; Cadiere, A; Thomas, O

    2012-08-30

    An inter-laboratory exercise was organized under the PHARMAS EU project, by the Advanced School of Public Health (EHESP), in order to evaluate the performances of analytical methods for the measurement of antibiotics in waters (surface and tap). This is the first time such an exercise on antibiotics has been organized in Europe, using different kinds of analytical methods and devices. In this exercise thirteen laboratories from five countries (Canada, France, Italy, the Netherlands and Portugal) participated, and a total number of 78 samples were distributed. During the exercise, 2 testing samples (3 bottles of each) prepared from tap water and river water, respectively, spiked with antibiotics, were sent to participants and analyzed over a period of one month. A final number of 77 (98.7%) testing samples were considered. Depending on substances studied by each participant, 305 values in duplicate were collected, with the results for each sample being expressed as the target concentration. A statistical study was initiated using 611 results. The mean value, standard deviation, coefficient of variation, standard uncertainty of the mean, median, the minimum and maximum values of each series as well as the 95% confidence interval were obtained from each participant laboratory. In this exercise, 36 results (6% of accounted values) were outliers according to the distribution over the median (box plot). The outlier results were excluded. In order to establish the stability of testing samples in the course of the exercise, differences between variances obtained for every type of sample at different intervals were evaluated. The results showed no representative variations and it can be considered that all samples were stable during the exercise. The goals of this inter-laboratory study were to assess results variability when analysis is conducted by different laboratories, to evaluate the influence of different matrix samples, and to determine the rate at which participating laboratories successfully completed the tests initiated. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Arsenic exposure in drinking water: an unrecognized health threat in Peru

    PubMed Central

    Sima, Laura; Arias, M Helena Jahuira; Mihalic, Jana; Cabrera, Lilia Z; Danz, David; Checkley, William; Gilman, Robert H

    2014-01-01

    Abstract Objective To assess the extent of arsenic contamination of groundwater and surface water in Peru and, to evaluate the accuracy of the Arsenic Econo-Quick™ (EQ) kit for measuring water arsenic concentrations in the field. Methods Water samples were collected from 151 water sources in 12 districts of Peru, and arsenic concentrations were measured in the laboratory using inductively-coupled plasma mass spectrometry. The EQ field kit was validated by comparing a subset of 139 water samples analysed by laboratory measurements and the EQ kit. Findings In 86% (96/111) of the groundwater samples, arsenic exceeded the 10 µg/l arsenic concentration guideline given by the World Health Organization (WHO) for drinking water. In 56% (62/111) of the samples, it exceeded the Bangladeshi threshold of 50 µg/l; the mean concentration being 54.5 µg/l (range: 0.1–93.1). In the Juliaca and Caracoto districts, in 96% (27/28) of groundwater samples arsenic was above the WHO guideline; and in water samples collected from the section of the Rímac river running through Lima, all had arsenic concentrations exceeding the WHO limit. When validated against laboratory values, the EQ kit correctly identified arsenic contamination relative to the guideline in 95% (106/111) of groundwater and in 68% (19/28) of surface water samples. Conclusion In several districts of Peru, drinking water shows widespread arsenic contamination, exceeding the WHO arsenic guideline. This poses a public health threat requiring further investigation and action. For groundwater samples, the EQ kit performed well relative to the WHO arsenic limit and therefore could provide a vital tool for water arsenic surveillance. PMID:25177071

  17. Clinical and Laboratory Data in a Sample of Greek Children with Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Ververi, Athina; Vargiami, Efthymia; Papadopoulou, Vassiliki; Tryfonas, Dimitrios; Zafeiriou, Dimitrios I.

    2012-01-01

    The purpose of this study is to describe clinical and laboratory data, as well as comorbid disorders in Greek children with autism spectrum disorders (ASD). Data were retrospectively collected for 222 children aged 1.5-9 years. The mean age at diagnosis was 43.7 [plus or minus] 17.6 months. Significantly earlier diagnoses were noted in children…

  18. LUNAR SAMPLES - APOLLO XI - MSC

    NASA Image and Video Library

    1969-08-03

    S69-40740 (July 1969) --- Dr. Ross Taylor (seated), Australian National University, and John Allen, Brown and Root-Northrop technician, review preliminary data from the optical emission spectrograph in the Spectrographic Laboratory of the Physical-Chemical Test Laboratory. Tests were being conducted on lunar surface material collected by astronauts Neil A. Armstrong and Edwin E. Aldrin Jr. during their lunar surface extravehicular activity on July 20, 1969.

  19. PIXE Analysis of Indoor Aerosols

    NASA Astrophysics Data System (ADS)

    Johnson, Christopher; Turley, Colin; Moore, Robert; Battaglia, Maria; Labrake, Scott; Vineyard, Michael

    2011-10-01

    We have performed a proton-induced X-ray emission (PIXE) analysis of aerosol samples collected in academic buildings at Union College to investigate the air quality in these buildings and the effectiveness of their air filtration systems. This is also the commissioning experiment for a new scattering chamber in the Union College Ion-Beam Analysis Laboratory. The aerosol samples were collected on Kapton foils using a nine-stage cascade impactor that separates particles according to their aerodynamic size. The foils were bombarded with beams of 2.2-MeV protons from the Union College 1.1-MV Pelletron Accelerator and the X-ray products were detected with an Amptek silicon drift detector. After subtracting the contribution from the Kapton foils, the X-ray energy spectra of the aerosol samples were analyzed using GUPIX software to determine the elemental concentrations of the samples. We will describe the collection of the aerosol samples, discuss the PIXE analysis, and present the results.

  20. Changes to Idaho's statewide surface-water quality monitoring program since 1995

    USGS Publications Warehouse

    O'Dell, Ivalou; Maret, Terry R.; Moore, Susan E.

    1998-01-01

    The program design included chemical analyses of water samples collected at 56 sites on the Bear, Clearwater, Kootenai, Pend Oreille, Salmon, Snake, and Spokane Rivers and their tributaries (fig. 1). Samples were collected every year (1990 through 1995) at 5 sites (annual sites), every other year at 19 sites (biennial sites), and every third year at 32 sites (triennial sites). Each year, 25 of the 56 sites were sampled. During water years 1990–95 (October 1, 1989, to September 30, 1995), samples were collected bimonthly. Onsite analyses consisted of discharge, specific conductance, pH, temperature, dissolved oxygen, bacteria (fecal coliform and fecal streptococci), and alkalinity. Laboratory analyses consisted of major ions, nutrients, trace elements, turbidity, and suspended sediment. Analytical results from the five annual sites sampled during water years 1990–93 are presented in a report by O’Dell and Berenbrock (1994).

  1. Laboratory electrical resistivity analysis of geologic samples from Fort Irwin, California: Chapter E in Geology and geophysics applied to groundwater hydrology at Fort Irwin, California

    USGS Publications Warehouse

    Bloss, Benjamin R.; Bedrosian, Paul A.; Buesch, David C.

    2015-01-01

    Correlating laboratory resistivity measurements with geophysical resistivity models helps constrain these models to the geology and lithology of an area. Throughout the Fort Irwin National Training Center area, 111 samples from both cored boreholes and surface outcrops were collected and processed for laboratory measurements. These samples represent various lithologic types that include plutonic and metamorphic (basement) rocks, lava flows, consolidated sedimentary rocks, and unconsolidated sedimentary deposits that formed in a series of intermountain basins. Basement rocks, lava flows, and some lithified tuffs are generally resistive (≥100 ohm-meters [Ω·m]) when saturated. Saturated unconsolidated samples are moderately conductive to conductive, with resistivities generally less than 100 Ω·m, and many of these samples are less than 50 Ω·m. The unconsolidated samples can further be separated into two broad groups: (1) younger sediments that are moderately conductive, owing to their limited clay content, and (2) older, more conductive sediments with a higher clay content that reflects substantial amounts of originally glassy volcanic ash subsequently altered to clay. The older sediments are believed to be Tertiary. Time-domain electromagnetic (TEM) data were acquired near most of the boreholes, and, on the whole, close agreements between laboratory measurements and resistivity models were found. 

  2. Optimization of the tungsten oxide technique for measurement of atmospheric ammonia

    NASA Technical Reports Server (NTRS)

    Brown, Kenneth G.

    1987-01-01

    Hollow tubes coated with tungstic acid have been shown to be of value in the determination of ammonia and nitric acid in ambient air. Practical application of this technique was demonstrated utilizing an automated sampling system for in-flight collection and analysis of atmospheric samples. Due to time constraints these previous measurements were performed on tubes that had not been well characterized in the laboratory. As a result the experimental precision could not be accurately estimated. Since the technique was being compared to other techniques for measuring these compounds, it became necessary to perform laboratory tests which would establish the reliability of the technique. This report is a summary of these laboratory experiments as they are applied to the determination of ambient ammonia concentration.

  3. Home Circadian Phase Assessments with Measures of Compliance Yield Accurate Dim Light Melatonin Onsets.

    PubMed

    Burgess, Helen J; Wyatt, James K; Park, Margaret; Fogg, Louis F

    2015-06-01

    There is a need for the accurate assessment of circadian phase outside of the clinic/laboratory, particularly with the gold standard dim light melatonin onset (DLMO). We tested a novel kit designed to assist in saliva sampling at home for later determination of the DLMO. The home kit includes objective measures of compliance to the requirements for dim light and half-hourly saliva sampling. Participants were randomized to one of two 10-day protocols. Each protocol consisted of two back-to-back home and laboratory phase assessments in counterbalanced order, separated by a 5-day break. Laboratory or participants' homes. Thirty-five healthy adults, age 21-62 y. N/A. Most participants received at least one 30-sec epoch of light > 50 lux during the home phase assessments (average light intensity 4.5 lux), but on average for < 9 min of the required 8.5 h. Most participants collected every saliva sample within 5 min of the scheduled time. Ninety-two percent of home DLMOs were not affected by light > 50 lux or sampling errors. There was no significant difference between the home and laboratory DLMOs (P > 0.05); on average the home DLMOs occurred 9.6 min before the laboratory DLMOs. The home DLMOs were highly correlated with the laboratory DLMOs (r = 0.91, P < 0.001). Participants were reasonably compliant to the home phase assessment procedures. The good agreement between the home and laboratory dim light melatonin onsets (DLMOs) demonstrates that including objective measures of light exposure and sample timing during home saliva sampling can lead to accurate home DLMOs. Circadian Phase Assessments at Home, http://clinicaltrials.gov/show/NCT01487252, NCT01487252. © 2015 Associated Professional Sleep Societies, LLC.

  4. DOE-OES-EML quality assurance program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanderson, C.G.

    1980-01-01

    Contractor laboratories handling radioactive materials for the US Department of Energy (DOE) are required to monitor the environmental exposure and publish annual reports for the Division of Operational and Environmental Safety (OES). In order to determine the validity of the data contained in these reports the Environmental Measurements Laboratory (EML) was requested to develop, coordinate, and conduct an Environmental Quality Assurance Program (QAP). There are four major phases to the DOE-OES-EML Quality Assurance Program: sample collection and preparation, sample analyses at EML, quarterly sample distribution, and reporting the data returned by the participants. The various phases of the QAP andmore » the data reported during the first year of the program are discussed.« less

  5. [Current biosafety in clinical laboratories in Japan: report of questionnaires' data obtained from clinical laboratory personnel in Japan].

    PubMed

    Goto, Mieko; Yamashita, Tomonari; Misawa, Shigeki; Komori, Toshiaki; Okuzumi, Katsuko; Takahashi, Takashi

    2007-01-01

    To determine the status of biosafety in clinical laboratories in Japan, we conducted a survey using questionnaires on the biosafety of laboratory personnel in 2004. We obtained data from 431 hospitals (response: 59.5%). Respondents were 301 institutions (70%) having biological safety cabinets (BSCs). BSCs were held in 78% of microbiological laboratories, 7.9% of genetic laboratories, 2.7% of histopathological laboratories, and 1% or less at other laboratories. A clean bench in examination rooms for acid-fast bacilli was applied at 20 hospitals. We found 28 cases of possible laboratory-associated tuberculosis infection, 25 of which were associated with lack of BSC. Other risk factors were immature skills and insufficiently skilled eguipment operation. The frequency of rupture accidents during specimen centrifugation was 67% in dealing with blood and 9.7% in collecting acid-fast bacilli. Half or more accidents were related to inadequate sample tube materials. Technologists were shown to be working on blood collection in many hospitals (75%), and 1,534 events of self-inflicted needle puncture developed in the last 5 years. These results suggest that biosafety systems are woefully lacking or inadequate in clinical laboratories in Japan and must be established at the earliest possible opportunity.

  6. Atmospheric Carbon Dioxide Mixing Ratios from the NOAA CMDL Carbon Cycle Cooperative Global Air Sampling Network (2009)

    DOE Data Explorer

    Conway, Thomas [NOAA Climate Monitoring and Diagnostics Laboratory, Boulder, CO (USA); Tans, Pieter [NOAA Climate Monitoring and Diagnostics Laboratory, Boulder, CO (USA)

    2009-01-01

    The National Oceanic and Atmospheric Administration's Climate Monitoring and Diagnostics Laboratory (NOAA/CMDL) has measured CO2 in air samples collected weekly at a global network of sites since the late 1960s. Atmospheric CO2 mixing ratios reported in these files were measured by a nondispersive infrared absorption technique in air samples collected in glass flasks. All CMDL flask samples are measured relative to standards traceable to the World Meteorological Organization (WMO) CO2 mole fraction scale. These measurements constitute the most geographically extensive, carefully calibrated, internally consistent atmospheric CO2 data set available and are essential for studies aimed at better understanding the global carbon cycle budget.

  7. Assessment of petroleum-hydrocarbon contamination in the surficial sediments and ground water at three former underground storage tank locations, Fort Jackson, South Carolina, 1995

    USGS Publications Warehouse

    Robertson, J.F.

    1996-01-01

    Ground-water and sediment contamination by petroleum hydrocarbons resulting from leaks and overfills was detected during tank removal activities at three former underground storage tank locations at Fort Jackson, near Columbia, South Carolina. Investigations were initiated to assess the effect of contamination to the surficial aquifer at Sites 1062, 2438, and 2444. These investigations involved the installation of permanent monitoring wells and the collection and analysis of sediment and ground-water samples at the three sites. Water-level data were collected at all sites to determine hydraulic gradients and the direction of ground-water flow. In addition, aquifer tests were made at Site 1062 to determine the hydraulic conductivity of the surficial aquifer at that site. Sediment borings were made at the three sites to collect subsurface-sediment samples for lithologic description and laboratory analyses, and for the installation of ground-water monitoring wells. Laboratory analyses of sediment samples collected from boreholes at Site 1062 indicated elevated concentrations of petroleum hydrocarbons at three locations. Total Petroleum Hydrocarbons - Diesel Range Organics were detected at one borehole at a concentration of 388,000 micrograms per kilogram. Total benzene, toluene, ethylbenzene, and xylene concentrations in sediment from the site ranged from less than 350 to over 100,000 micrograms per kilogram. Total lead was detected at concentrations ranging from 2,900 to 5,900 micrograms per kilogram. Petroleum hydrocarbons were detected at Site 2438 in one borehole at a trace concentration of 112 micrograms per kilogram of para- and meta-xylenes. No concentrations exceeding the detection limits were reported for petroleum hydrocarbons in sediment samples collected from Site 2444; however, total lead was detected in sediment samples from two boreholes, each at concentrations of 600 micrograms per kilogram. Ground-water samples were collected from each site for laboratory analysis and field-property determinations. Petroleum hydrocarbons and lead were detected at concentrations exceeding regulatory limits for drinking water in ground water from Site 1062 only. Petroleum hydrocarbons were detected in ground water from three wells at Site 1062, with the highest concentrations occurring in the area of the former underground storage tanks. Benzene was detected at concentrations as much as 28 micrograms per liter; toluene as much as 558 micrograms per liter; para- and meta-xylenes as much as 993 micrograms per liter; and naphthalene as much as 236 micrograms per liter. Ethylbenzene and ortho-xylene were detected in one well at concentrations of 70 and 6 micrograms per liter, respectively. Dissolved lead was detected in ground water from four wells at concentrations from 5 to 152 micrograms per liter. Analysis of ground-water samples collected from Sites 2438 and 2444 showed little evidence of petroleum-hydrocarbon contamination. Petroleum hydrocarbons were not detected in any of the ground-water samples collected from Site 2438. With the exception of a low concentration of naphthalene (11 micrograms per liter) detected in ground water from one well, petroleum hydrocarbons and lead were not detected in ground water collected from Site 2444.

  8. Onsite Gaseous Centrifuge Enrichment Plant UF6 Cylinder Destructive Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anheier, Norman C.; Cannon, Bret D.; Qiao, Hong

    2012-07-17

    The IAEA safeguards approach for gaseous centrifuge enrichment plants (GCEPs) includes measurements of gross, partial, and bias defects in a statistical sampling plan. These safeguard methods consist principally of mass and enrichment nondestructive assay (NDA) verification. Destructive assay (DA) samples are collected from a limited number of cylinders for high precision offsite mass spectrometer analysis. DA is typically used to quantify bias defects in the GCEP material balance. Under current safeguards measures, the operator collects a DA sample from a sample tap following homogenization. The sample is collected in a small UF6 sample bottle, then sealed and shipped under IAEAmore » chain of custody to an offsite analytical laboratory. Current practice is expensive and resource intensive. We propose a new and novel approach for performing onsite gaseous UF6 DA analysis that provides rapid and accurate assessment of enrichment bias defects. DA samples are collected using a custom sampling device attached to a conventional sample tap. A few micrograms of gaseous UF6 is chemically adsorbed onto a sampling coupon in a matter of minutes. The collected DA sample is then analyzed onsite using Laser Ablation Absorption Ratio Spectrometry-Destructive Assay (LAARS-DA). DA results are determined in a matter of minutes at sufficient accuracy to support reliable bias defect conclusions, while greatly reducing DA sample volume, analysis time, and cost.« less

  9. Automation and validation of DNA-banking systems.

    PubMed

    Thornton, Melissa; Gladwin, Amanda; Payne, Robin; Moore, Rachael; Cresswell, Carl; McKechnie, Douglas; Kelly, Steve; March, Ruth

    2005-10-15

    DNA banking is one of the central capabilities on which modern genetic research rests. The DNA-banking system plays an essential role in the flow of genetic data from patients and genetics researchers to the application of genetic research in the clinic. Until relatively recently, large collections of DNA samples were not common in human genetics. Now, collections of hundreds of thousands of samples are common in academic institutions and private companies. Automation of DNA banking can dramatically increase throughput, eliminate manual errors and improve the productivity of genetics research. An increased emphasis on pharmacogenetics and personalized medicine has highlighted the need for genetics laboratories to operate within the principles of a recognized quality system such as good laboratory practice (GLP). Automated systems are suitable for such laboratories but require a level of validation that might be unfamiliar to many genetics researchers. In this article, we use the AstraZeneca automated DNA archive and reformatting system (DART) as a case study of how such a system can be successfully developed and validated within the principles of GLP.

  10. Tethered-restraint system for blood collection from ferrets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jackson, R.K.; Kieffer, V.A.; Sauber, J.S.

    The laboratory ferret, Mustela putorius furo, recently has come into prominence as a laboratory animal for use in biomedical research. This laboratory has adopted the use of this species because the ferret's emetic response to radiation occurs at a lower dose and has a more rapid onset than that of dogs. One approach for determining the physiological basis of this response is to measure serum levels of various circulating substances before and after irradiation. However, blood collection from the ferret can be difficult because the lack of easily accessible veins and seasonal accumulation of subcutaneous body fat. This report describesmore » a method of tethered-restraint for the ferret in which an in-dwelling venous jugular catheter is implanted for withdrawing blood samples. No interference with the animal's normal activities occurs during the sampling procedure. Each animal is conditioned to the tethered-restraint prior to surgical placement of the catheter. The technique provides a minimally stressful method of restraint. A similar tethering system has been used successfully on several other animal species, such as non-human primates and rats.« less

  11. Methodological considerations for implementation of lymphocyte subset analysis in a clinical reference laboratory.

    PubMed

    Muirhead, K A; Wallace, P K; Schmitt, T C; Frescatore, R L; Franco, J A; Horan, P K

    1986-01-01

    As the diagnostic utility of lymphocyte subset analysis has been recognized in the clinical research laboratory, a wide variety of reagents and cell preparation, staining and analysis methods have also been described. Methods that are perfectly suitable for analysis of smaller sample numbers in the biological or clinical research setting are not always appropriate and/or applicable in the setting of a high volume clinical reference laboratory. We describe here some of the specific considerations involved in choosing a method for flow cytometric analysis which minimizes sample preparation and data analysis time while maximizing sample stability, viability, and reproducibility. Monoclonal T- and B-cell reagents from three manufacturers were found to give equivalent results for a reference population of healthy individuals. This was true whether direct or indirect immunofluorescence staining was used and whether cells were prepared by Ficoll-Hypaque fractionation (FH) or by lysis of whole blood. When B cells were enumerated using a polyclonal anti-immunoglobulin reagent, less cytophilic immunoglobulin staining was present after lysis than after FH preparation. However, both preparation methods required additional incubation at 37 degrees C to obtain results concordant with monoclonal B-cell reagents. Standard reagents were chosen on the basis of maximum positive/negative separation and the availability of appropriate negative controls. The effects of collection medium and storage conditions on sample stability and reproducibility of subset analysis were also assessed. Specimens collected in heparin and stored at room temperature in buffered medium gave reproducible results for 3 days after specimen collection, using either FH or lysis as the preparation method. General strategies for instrument optimization, quality control, and biohazard containment are also discussed.

  12. Concentrations of tritium and strontium-90 in water from selected wells at the Idaho National Engineering Laboratory after purging one, two, and three borehole volumes

    USGS Publications Warehouse

    Bartholomay, R.C.

    1993-01-01

    Water from 11 wells completed in the Snake River Plain aquifer at the Idaho National Engineering Laboratory was sampled as part of the U.S. Geological Survey's quality assurance program to determine the effect of purging different borehole volumes on tritium and strontium-90 concentrations. Wells were selected for sampling on the basis of the length of time it took to purge a borehole volume of water. Samples were collected after purging one, two, and three borehole volumes. The U.S. Department of Energy's Radiological and Environmental Sciences Laboratory provided analytical services. Statistics were used to determine the reproducibility of analytical results. The comparison between tritium and strontium-90 concentrations after purging one and three borehole volumes and two and three borehole volumes showed that all but two sample pairs with defined numbers were in statistical agreement. Results indicate that concentrations of tritium and strontium-90 are not affected measurably by the number of borehole volumes purged.

  13. Short communication: Analytical method and amount of preservative added to milk samples may alter milk urea nitrogen measurements.

    PubMed

    Weeks, Holley L; Hristov, Alexander N

    2017-02-01

    Milk urea N (MUN) is used by dairy nutritionists and producers to monitor dietary protein intake and is indicative of N utilization in lactating dairy cows. Two experiments were conducted to explore discrepancies in MUN results provided by 3 milk processing laboratories using different methods. An additional experiment was conducted to evaluate the effect of 2-bromo-2-nitropropane-1, 3-diol (bronopol) on MUN analysis. In experiment 1, 10 replicates of bulk tank milk samples, collected from the Pennsylvania State University's Dairy Center over 5 consecutive days, were sent to 3 milk processing laboratories in Pennsylvania. Average MUN differed between laboratory A (14.9 ± 0.40 mg/dL; analyzed on MilkoScan 4000; Foss, Hillerød, Denmark), laboratory B (6.5 ± 0.17 mg/dL; MilkoScan FT + 6000), and laboratory C (7.4 ± 0.36 mg/dL; MilkoScan 6000). In experiment 2, milk samples were spiked with urea at 0 (7.3 to 15.0 mg/dL, depending on the laboratory analyzing the samples), 17.2, 34.2, and 51.5 mg/dL of milk. Two 35-mL samples from each urea level were sent to the 3 laboratories used in experiment 1. Average analyzed MUN was greater than predicted (calculated for each laboratory based on the control; 0 mg of added urea): for laboratory A (23.2 vs. 21.0 mg/dL), laboratory B (18.0 vs. 13.3 mg/dL), and laboratory C (20.6 vs. 15.2 mg/dL). In experiment 3, replicated milk samples were preserved with 0 to 1.35 mg of bronopol/mL of milk and submitted to one milk processing laboratory that analyzed MUN using 2 different methods. Milk samples with increasing amounts of bronopol ranged in MUN concentration from 7.7 to 11.9 mg/dL and from 9.0 to 9.3 mg/dL when analyzed on MilkoScan 4000 or CL 10 (EuroChem, Moscow, Russia), respectively. In conclusion, measured MUN concentrations varied due to analytical procedure used by milk processing laboratories and were affected by the amount of bronopol used to preserve milk sample, when milk was analyzed using a mid-infrared analyzer. Thus, it is important to maintain consistency in milk sample preservation and analysis to ensure precision of MUN results. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  14. Spices as a source of lead exposure: a market-basket survey in Sri Lanka.

    PubMed

    Senanayake, M P; Perera, R; Liyanaarachchi, L A; Dassanayake, M P

    2013-12-01

    We performed a laboratory analysis of spices sold in Sri Lanka for lead content. Samples of curry powder, chili powder and turmeric powder from seven provinces, collected using the market basket survey method, underwent atomic absorption spectrometry. Blanks and standards were utilised for instrument calibration and measurement accuracy. The results were validated in two different laboratories. All samples were found to have lead levels below the US Food and Drug Administration's action level of 0.5 μg/g. Spices sold in Sri Lanka contain lead concentrations that are low and within the stipulated safety standards.

  15. Water-quality data of soil water from three watersheds, Shenandoah National Park, Virginia, 1999-2000

    USGS Publications Warehouse

    Rice, Karen C.; Maben, Suzanne W.; Webb, James R.

    2001-01-01

    Data on the chemical composition of soil-water samples were collected quarterly from three watersheds in Shenandoah National Park, Virginia, from September 1999 through July 2000. The soil-water samples were analyzed for specific conductance and concentrations of sodium, potassium, calcium, magnesium, ammonium, chloride, nitrate, sulfate, acid-neutralizing capacity, silica, and total monomeric aluminum. The soil-water data presented in this report can be used to support water-quality modeling of the response of streams to episodic acidification. Laboratory analytical data as well as laboratory quality-assurance information also are presented.

  16. Integrated Verification Experiment data collected as part of the Los Alamos National Laboratory`s Source Region Program. Appendix D: Ionospheric measurements for IVEs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fitzgerald, T.J.; Carlos, R.C.; Argo, P.E.

    As part of the integrated verification experiment (IVE), we deployed a network of hf ionospheric sounders to detect the effects of acoustic waves generated by surface ground motion following underground nuclear tests at the Nevada Test Site. The network sampled up to four geographic locations in the ionosphere from almost directly overhead of the surface ground zero out to a horizontal range of 60 km. We present sample results for four of the IVEs: Misty Echo, Texarkana, Mineral Quarry, and Bexar.

  17. California GAMA Special Study. Development of a Capability for the Analysis of Krypton-85 in Groundwater Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Visser, Ate; Bibby, Richard K.; Moran, Jean E.

    A capability for the analysis of krypton-85 ( 85Kr) in groundwater samples was developed at LLNL. Samples are collected by extracting gas from 2000-4000 L of groundwater at the well, yielding approximately 0.2 cm 3 STP krypton. Sample collection takes 1 to 4 hours. Krypton is purified in the laboratory using a combination of molecular sieve and activated charcoal traps, and transferred to a liquid scintillation vial. The 85Kr activity is measured by liquid scintillation on a Quantulus 1220 liquid scintillation counter from PerkinElmer. The detection limit for a typical 0.2 cm 3Kr sample size is 11% of the presentmore » day activity in air, corresponding to the decay corrected activity in air in 1987. The typical measurement uncertainty is below 10% for recently recharged samples. Six groundwater samples were collected, purified and counted. 85Kr was not detected in any of the samples counted at LLNL. 85Kr was detected by the low level counting laboratory of Bern University in all samples between 1.5 and 6.6 decays per minute per cm 3 krypton, corresponding to decay corrected activities in air between 1971 and 1985. The new capability is an excellent complement to tritium-helium, expanding the existing suite of age dating tools available to the GAMA program ( 35S, 3H/ 3He, 14C and radiogenic helium). 85Kr can replace 3H/ 3He in settings where 3H/ 3He ages are impossible to determine (for example where terrigenic helium overwhelms tritiogenic helium) and provides additional insight into travel time distributions in complex mixed groundwater systems.« less

  18. Internal validation of the DNAscan/ANDE™ Rapid DNA Analysis™ platform and its associated PowerPlex® 16 high content DNA biochip cassette for use as an expert system with reference buccal swabs.

    PubMed

    Moreno, Lilliana I; Brown, Alice L; Callaghan, Thomas F

    2017-07-01

    Rapid DNA platforms are fully integrated systems capable of producing and analyzing short tandem repeat (STR) profiles from reference sample buccal swabs in less than two hours. The technology requires minimal user interaction and experience making it possible for high quality profiles to be generated outside an accredited laboratory. The automated production of point of collection reference STR profiles could eliminate the time delay for shipment and analysis of arrestee samples at centralized laboratories. Furthermore, point of collection analysis would allow searching against profiles from unsolved crimes during the normal booking process once the infrastructure to immediately search the Combined DNA Index System (CODIS) database from the booking station is established. The DNAscan/ANDE™ Rapid DNA Analysis™ System developed by Network Biosystems was evaluated for robustness and reliability in the production of high quality reference STR profiles for database enrollment and searching applications. A total of 193 reference samples were assessed for concordance of the CODIS 13 loci. Studies to evaluate contamination, reproducibility, precision, stutter, peak height ratio, noise and sensitivity were also performed. The system proved to be robust, consistent and dependable. Results indicated an overall success rate of 75% for the 13 CODIS core loci and more importantly no incorrect calls were identified. The DNAscan/ANDE™ could be confidently used without human interaction in both laboratory and non-laboratory settings to generate reference profiles. Published by Elsevier B.V.

  19. Total airborne mold particle sampling: evaluation of sample collection, preparation and counting procedures, and collection devices.

    PubMed

    Godish, Diana; Godish, Thad

    2008-02-01

    This study was conducted to evaluate (i) procedures used to collect, prepare, and count total airborne mold spore/particle concentrations, and (ii) the relative field performance of three commercially available total airborne mold spore/particle sampling devices. Differences between factory and laboratory airflow calibration values of axial fan-driven sampling instruments (used in the study) indicated a need for laboratory calibration using a mass flow meter to ensure that sample results were accurately calculated. An aniline blue-amended Calberla's solution adjusted to a pH of 4.2-4.4 provided good sample mounting/counting results using Dow Corning high vacuum grease, Dow Corning 280A adhesive, and Dow Corning 316 silicone release spray for samples collected using mini-Burkard and Allergenco samplers. Count variability among analysts was most pronounced in 5% counts of relatively low mold particle deposition density samples and trended downward with increased count percentage and particle deposition density. No significant differences were observed among means of 5, 10, and 20% counts and among analysts; a significant interaction effect was observed between analysts' counts and particle deposition densities. Significantly higher mini-Burkard and Air-O-Cell total mold spore/particle counts for 600x vs. 400x (1.9 and 2.3 x higher, respectively), 1000x vs. 600x (1.9 and 2.2 x higher, respectively) and 1000x vs. 400x (3.6 and 4.6 x higher, respectively) comparisons indicated that 1000x magnification counts best quantified total airborne mold spore/particles using light microscopy, and that lower magnification counts may result in unacceptable underreporting of airborne mold spore/particle concentrations. Modest but significantly higher (1.2x) total mold spore concentrations were observed with Allergenco vs. mini-Burkard samples collected in co-located, concurrently operated sampler studies; moderate but significantly higher mini-Burkard count values (1.4x) were observed in similar studies with Air-O-Cell samplers. These count differences were relatively small compared with the large differences observed among three count magnifications.

  20. Clandestine laboratory scene investigation and processing using portable GC/MS

    NASA Astrophysics Data System (ADS)

    Matejczyk, Raymond J.

    1997-02-01

    This presentation describes the use of portable gas chromatography/mass spectrometry for on-scene investigation and processing of clandestine laboratories. Clandestine laboratory investigations present special problems to forensic investigators. These crime scenes contain many chemical hazards that must be detected, identified and collected as evidence. Gas chromatography/mass spectrometry performed on-scene with a rugged, portable unit is capable of analyzing a variety of matrices for drugs and chemicals used in the manufacture of illicit drugs, such as methamphetamine. Technologies used to detect various materials at a scene have particular applications but do not address the wide range of samples, chemicals, matrices and mixtures that exist in clan labs. Typical analyses performed by GC/MS are for the purpose of positively establishing the identity of starting materials, chemicals and end-product collected from clandestine laboratories. Concerns for the public and investigator safety and the environment are also important factors for rapid on-scene data generation. Here is described the implementation of a portable multiple-inlet GC/MS system designed for rapid deployment to a scene to perform forensic investigations of clandestine drug manufacturing laboratories. GC/MS has long been held as the 'gold standard' in performing forensic chemical analyses. With the capability of GC/MS to separate and produce a 'chemical fingerprint' of compounds, it is utilized as an essential technique for detecting and positively identifying chemical evidence. Rapid and conclusive on-scene analysis of evidence will assist the forensic investigators in collecting only pertinent evidence thereby reducing the amount of evidence to be transported, reducing chain of custody concerns, reducing costs and hazards, maintaining sample integrity and speeding the completion of the investigative process.

  1. Development and inter-laboratory validation study of an improved new real-time PCR assay with internal control for detection and laboratory diagnosis of African swine fever virus.

    PubMed

    Tignon, Marylène; Gallardo, Carmina; Iscaro, Carmen; Hutet, Evelyne; Van der Stede, Yves; Kolbasov, Denis; De Mia, Gian Mario; Le Potier, Marie-Frédérique; Bishop, Richard P; Arias, Marisa; Koenen, Frank

    2011-12-01

    A real-time polymerase chain reaction (PCR) assay for the rapid detection of African swine fever virus (ASFV), multiplexed for simultaneous detection of swine beta-actin as an endogenous control, has been developed and validated by four National Reference Laboratories of the European Union for African swine fever (ASF) including the European Union Reference Laboratory. Primers and a TaqMan(®) probe specific for ASFV were selected from conserved regions of the p72 gene. The limit of detection of the new real-time PCR assay is 5.7-57 copies of the ASFV genome. High accuracy, reproducibility and robustness of the PCR assay (CV ranging from 0.7 to 5.4%) were demonstrated both within and between laboratories using different real-time PCR equipments. The specificity of virus detection was validated using a panel of 44 isolates collected over many years in various geographical locations in Europe, Africa and America, including recent isolates from the Caucasus region, Sardinia, East and West Africa. Compared to the OIE-prescribed conventional and real-time PCR assays, the sensitivity of the new assay with internal control was improved, as demonstrated by testing 281 field samples collected in recent outbreaks and surveillance areas in Europe and Africa (170 samples) together with samples obtained through experimental infections (111 samples). This is particularly evident in the early days following experimental infection and during the course of the disease in pigs sub-clinically infected with strains of low virulence (from 35 up to 70dpi). The specificity of the assay was also confirmed on 150 samples from uninfected pigs and wild boar from ASF-free areas. Measured on the total of 431 tested samples, the positive deviation of the new assay reaches 21% or 26% compared to PCR and real-time PCR methods recommended by OIE. This improved and rigorously validated real-time PCR assay with internal control will provide a rapid, sensitive and reliable molecular tool for ASFV detection in pigs in newly infected areas, control in endemic areas and surveillance in ASF-free areas. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Technical Tension Between Achieving Particulate and Molecular Organic Environmental Cleanliness: Data from Astromaterial Curation Laboratories

    NASA Technical Reports Server (NTRS)

    Allton, J. H.; Burkett, P. J.

    2011-01-01

    NASA Johnson Space Center operates clean curation facilities for Apollo lunar, Antarctic meteorite, stratospheric cosmic dust, Stardust comet and Genesis solar wind samples. Each of these collections is curated separately due unique requirements. The purpose of this abstract is to highlight the technical tensions between providing particulate cleanliness and molecular cleanliness, illustrated using data from curation laboratories. Strict control of three components are required for curating samples cleanly: a clean environment; clean containers and tools that touch samples; and use of non-shedding materials of cleanable chemistry and smooth surface finish. This abstract focuses on environmental cleanliness and the technical tension between achieving particulate and molecular cleanliness. An environment in which a sample is manipulated or stored can be a room, an enclosed glovebox (or robotic isolation chamber) or an individual sample container.

  3. Assessment of nonpoint source chemical loading potential to watersheds containing uranium waste dumps and human health hazards associated with uranium exploration and mining, Red, White, and Fry Canyons, southeastern Utah, 2007

    USGS Publications Warehouse

    Beisner, Kimberly R.; Marston, Thomas M.; Naftz, David L.; Snyder, Terry; Freeman, Michael L.

    2010-01-01

    During May, June, and July 2007, 58 solid-phase samples were collected from abandoned uranium mine waste dumps, background sites, and adjacent streambeds in Red, White, and Fry Canyons in southeastern Utah. The objectives of this sampling program were to (1) assess the nonpoint-source chemical loading potential to ephemeral and perennial drainage basins from uranium waste dumps and (2) assess potential effects on human health due to recreational activities on and around uranium waste dumps on Bureau of Land Management property. Uranium waste-dump samples were collected using solid-phase sampling protocols. After collection, solid-phase samples were homogenized and extracted in the laboratory using a leaching procedure. Filtered (0.45 micron) water samples were obtained from the field leaching procedure and were analyzed for major and trace elements at the Inductively Coupled Plasma-Mass Spectrometry Metals Analysis Laboratory at the University of Utah. A subset of the solid-phase samples also were digested with strong acids and analyzed for major ions and trace elements at the U.S. Geological Survey Geologic Division Laboratory in Denver, Colorado. For the initial ranking of chemical loading potential for uranium waste dumps, results of leachate analyses were compared with existing aquatic-life and drinking-water-quality standards. To assess potential effects on human health, solid-phase digestion values for uranium were compared to soil screening levels (SSL) computed using the computer model RESRAD 6.5 for a probable concentration of radium. One or more chemical constituents exceeded aquatic life and drinking-water-quality standards in approximately 64 percent (29/45) of the leachate samples extracted from uranium waste dumps. Most of the uranium waste dump sites with elevated trace-element concentrations in leachates were located in Red Canyon. Approximately 69 percent (31/45) of the strong acid digestible soil concentration values were greater than a calculated SSL. Uranium waste dump sites with elevated leachate and total digestible concentrations may need to be further investigated to determine the most appropriate remediation method.

  4. We Did This Before - The Lunar Receiving Laboratory (1969-1972)

    NASA Technical Reports Server (NTRS)

    Allen, Carlton; Allton, Judith

    2011-01-01

    The six Apollo missions to the lunar surface, between 1969 and 1972, returned 2,196 individual rock, soil and core samples, with a total mass of 381.69 kg. The astronauts selected samples, photographed the rocks and soils prior to collection, packaged them in uniquely identified containers, and transported them to the Lunar Module

  5. 21 CFR 809.40 - Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IN VITRO DIAGNOSTIC PRODUCTS FOR HUMAN USE Requirements for Manufacturers and Producers § 809.40... set forth in this section. (b) Sample testing shall be performed in a laboratory using screening tests...

  6. 21 CFR 809.40 - Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IN VITRO DIAGNOSTIC PRODUCTS FOR HUMAN USE Requirements for Manufacturers and Producers § 809.40... set forth in this section. (b) Sample testing shall be performed in a laboratory using screening tests...

  7. Synchronous in-field application of life-detection techniques in planetary analog missions

    NASA Astrophysics Data System (ADS)

    Amador, Elena S.; Cable, Morgan L.; Chaudry, Nosheen; Cullen, Thomas; Gentry, Diana; Jacobsen, Malene B.; Murukesan, Gayathri; Schwieterman, Edward W.; Stevens, Adam H.; Stockton, Amanda; Yin, Chang; Cullen, David C.; Geppert, Wolf

    2015-02-01

    Field expeditions that simulate the operations of robotic planetary exploration missions at analog sites on Earth can help establish best practices and are therefore a positive contribution to the planetary exploration community. There are many sites in Iceland that possess heritage as planetary exploration analog locations and whose environmental extremes make them suitable for simulating scientific sampling and robotic operations. We conducted a planetary exploration analog mission at two recent lava fields in Iceland, Fimmvörðuháls (2010) and Eldfell (1973), using a specially developed field laboratory. We tested the utility of in-field site sampling down selection and tiered analysis operational capabilities with three life detection and characterization techniques: fluorescence microscopy (FM), adenine-triphosphate (ATP) bioluminescence assay, and quantitative polymerase chain reaction (qPCR) assay. The study made use of multiple cycles of sample collection at multiple distance scales and field laboratory analysis using the synchronous life-detection techniques to heuristically develop the continuing sampling and analysis strategy during the expedition. Here we report the operational lessons learned and provide brief summaries of scientific data. The full scientific data report will follow separately. We found that rapid in-field analysis to determine subsequent sampling decisions is operationally feasible, and that the chosen life detection and characterization techniques are suitable for a terrestrial life-detection field mission. In-field analysis enables the rapid obtainment of scientific data and thus facilitates the collection of the most scientifically relevant samples within a single field expedition, without the need for sample relocation to external laboratories. The operational lessons learned in this study could be applied to future terrestrial field expeditions employing other analytical techniques and to future robotic planetary exploration missions.

  8. Salinity of ground water at sampling wells located in southeastern Nassau County, Long Island, New York

    USGS Publications Warehouse

    Lusczynski, Norbert J.

    1950-01-01

    In 1939, a special program for the systematic collection of chloride data in southeastern Nassau County was inaugurated in which three agencies participated. The Nassau County Department of Public Works constructed the sampling wells, the Ground Water Branch of the U.S. Geological Survey began to collect at period intervals water samples which were analysed at the Mount Prospect Laboratory of the New York Department of Water Supply, Gas and Electricity, The Nassau County Department of Public Works and the U.S. Geological Survey have continued financial cooperation for the maintenance of this program up to the present time.

  9. Trace gas measurements from whole air samples collected over the Antarctic continent

    NASA Technical Reports Server (NTRS)

    Heidt, L. E.; Vedder, J. F.; Pollock, Walter H.; Henry, Bruce E.; Lueb, Richard A.

    1988-01-01

    Whole air samples collected aboard the NASA DC-8 and ER-2 aircraft as part of the Airborne Antarctic Ozone Experiment (AAOE) were analyzed in a field laboratory set up at Punta Arenas, Chile, in August and September, 1987. Mixing ratios obtained from gas chromatographic analyses of these samples are presented for N2O, CFCl3, CFCl2, C2F3Cl3, CH3CCl3, CH4, and CO. Variations in the mixing ratios of these gases along the individual flight paths of the aircraft are used as tracers to indicate the history of air masses over and near the Antarctic continent.

  10. Sensitive and specific identification by polymerase chain reaction of Eimeria tenella and Eimeria maxima, important protozoan pathogens in laboratory avian facilities.

    PubMed

    Lee, Hyun-A; Hong, Sunhwa; Chung, Yungho; Kim, Okjin

    2011-09-01

    Eimeria tenella and Eimeria maxima are important pathogens causing intracellular protozoa infections in laboratory avian animals and are known to affect experimental results obtained from contaminated animals. This study aimed to find a fast, sensitive, and efficient protocol for the molecular identification of E. tenella and E. maxima in experimental samples using chickens as laboratory avian animals. DNA was extracted from fecal samples collected from chickens and polymerase chain reaction (PCR) analysis was employed to detect E. tenella and E. maxima from the extracted DNA. The target nucleic acid fragments were specifically amplified by PCR. Feces secreting E. tenella and E. maxima were detected by a positive PCR reaction. In this study, we were able to successfully detect E. tenella and E. maxima using the molecular diagnostic method of PCR. As such, we recommended PCR for monitoring E. tenella and E. maxima in laboratory avian facilities.

  11. A portable cryo-plunger for on-site intact cryogenic microscopy sample preparation in natural environments.

    PubMed

    Comolli, Luis R; Duarte, Robert; Baum, Dennis; Luef, Birgit; Downing, Kenneth H; Larson, David M; Csencsits, Roseann; Banfield, Jillian F

    2012-06-01

    We present a modern, light portable device specifically designed for environmental samples for cryogenic transmission-electron microscopy (cryo-TEM) by on-site cryo-plunging. The power of cryo-TEM comes from preparation of artifact-free samples. However, in many studies, the samples must be collected at remote field locations, and the time involved in transporting samples back to the laboratory for cryogenic preservation can lead to severe degradation artifacts. Thus, going back to the basics, we developed a simple mechanical device that is light and easy to transport on foot yet effective. With the system design presented here we are able to obtain cryo-samples of microbes and microbial communities not possible to culture, in their near-intact environmental conditions as well as in routine laboratory work, and in real time. This methodology thus enables us to bring the power of cryo-TEM to microbial ecology. Copyright © 2011 Wiley Periodicals, Inc.

  12. [Standardization of Blastocystis hominis diagnosis using different staining techniques].

    PubMed

    Eymael, Dayane; Schuh, Graziela Maria; Tavares, Rejane Giacomelli

    2010-01-01

    The present study was carried out from March to May 2008, with the aim of evaluating the effectiveness of different techniques for diagnosing Blastocystis hominis in a sample of the population attended at the Biomedicine Laboratory of Feevale University, Novo Hamburgo, Rio Grande do Sul. On hundred feces samples from children and adults were evaluated. After collection, the samples were subjected to the techniques of spontaneous sedimentation (HPJ), sedimentation in formalin-ether (Ritchie) and staining by means of Gram and May-Grünwald-Giemsa (MGG). The presence of Blastocystis hominis was observed in 40 samples, when staining techniques were used (MGG and Gram), while sedimentation techniques were less efficient (32 positive samples using the Ritchie technique and 20 positive samples using the HPJ technique). Our results demonstrate that HPJ was less efficient than the other methods, thus indicating the need to include laboratory techniques that enable parasite identification on a routine basis.

  13. Laboratory measurements of electric properties of composite mine dump samples from Colorado and New Mexico

    USGS Publications Warehouse

    Anderson, Anita L.; Campbell, David L.; Beanland, Shay

    2001-01-01

    Individual mine waste samples were collected and combined to form one composite sample at each of eight mine dump sites in Colorado and New Mexico. The samples were air-dried and sieved to determine the geochemical composition of their <2mm size fraction. Splits of the samples were then rehydrated and their electrical properties were measured in the US Geological Survey Petrophysical Laboratory, Denver, Colorado (PetLab). The PetLab measurements were done twice: in 1999, using convenient amounts of rehydration water ranging from 5% to 8%; and in 2000, using carefully controlled rehydrations to 5% and 10% water. This report gives geochemical analyses of the <2mm size fraction of the composite samples (Appendix A), PetLab graphs of the 1999 measurements (Appendix B), Petlab graphs of the 2000 measurements (Appendix C), and Cole-Cole models of the PetLab data from the 2000 measurements (Appendix D).

  14. Experimental Investigations in Nonlinear Viscous Behavior of Subgrade Soils Under Traffic-Induced Loading

    DOT National Transportation Integrated Search

    1999-08-01

    This paper concerns experimental investigations of nonlinear viscosity of : subgrade soils under vehicle-induced loading. Subgrade soil samples--collected : from the Soil/Aggregate Laboratory at the Geotechnical Exploration Division at : the Maryland...

  15. High Throughput Determination of Tetramine in Drinking ...

    EPA Pesticide Factsheets

    Report The sampling and analytical procedure (SAP) presented herein, describes a method for the high throughput determination of tetramethylene disulfotetramine in drinking water by solid phase extraction and isotope dilution gas chromatography/mass spectrometry. This method, which will be included in the SAM, is expected to provide the Water Laboratory Alliance, as part of EPA’s Environmental Response Laboratory Network, with a more reliable and faster means of analyte collection and measurement.

  16. Acid-Soluble Internal Capsules for Closed-Face Cassette Elemental Sampling and Analysis of Workplace Air

    PubMed Central

    Harper, Martin; Ashley, Kevin

    2013-01-01

    Airborne particles that are collected using closed-face filter cassettes (CFCs), which are used widely in the sampling of workplace aerosols, can deposit in places other than on the filter and thereby may not be included in the ensuing analysis. A technique for ensuring that internal non-filter deposits are included in the analysis is to collect airborne particles within an acid-soluble internal capsule that, following sampling, can be dissolved along with the filter for subsequent elemental analysis. An interlaboratory study (ILS) was carried out to evaluate the use of cellulosic CFC capsule inserts for their suitability in the determination of trace elements in airborne samples. The ILS was performed in accordance with an applicable ASTM International standard practice, ASTM E691, which describes statistical procedures for investigating interlaboratory precision. Performance evaluation materials consisted of prototype cellulose acetate capsules attached to mixed-cellulose ester filters. Batches of capsules were dosed with Pb-containing materials (standard aqueous solutions, and certified reference material soil and paint). Also, aerosol samples containing nine target analyte elements (As, Cd, Co, Cr, Cu, Fe, Pb, Mn, and Ni) were generated using a multiport sampler; various concentrations and sampling times were employed to yield samples fortified at desired loading levels. Triplicates of spiked capsules at three different loadings were conveyed to each volunteer laboratory; loading levels were unknown to the participants. The laboratories were asked to prepare the samples by acid dissolution and to analyze aliquots of extracted samples by atomic spectrometry in accordance with applicable ASTM International Standards. Participants were asked to report their results in units of μg of each target element per sample. For the elements investigated, interlaboratory precision and recovery estimates from the participating laboratories demonstrated the utility of the cellulosic capsule inserts for the measurement of sampled trace elements. PMID:23548078

  17. Particle atlas of World Trade Center dust

    USGS Publications Warehouse

    Lowers, Heather; Meeker, Gregory P.

    2005-01-01

    The United States Environmental Protection Agency (EPA) has begun a reassessment of the presence of World Trade Center (WTC) dust in residences, public buildings, and office spaces in New York City, New York. Background dust samples collected from residences, public buildings, and office spaces will be analyzed by multiple laboratories for the presence of WTC dust. Other laboratories are currently studying WTC dust for other purposes, such as health effects studies. To assist in inter-laboratory consistency for identification of WTC dust components, this particle atlas of phases in WTC dust has been compiled.

  18. Oil mist and vapour concentrations from drilling fluids: inter- and intra-laboratory comparison of chemical analyses.

    PubMed

    Galea, Karen S; Searl, Alison; Sánchez-Jiménez, Araceli; Woldbæk, Torill; Halgard, Kristin; Thorud, Syvert; Steinsvåg, Kjersti; Krüger, Kirsti; Maccalman, Laura; Cherrie, John W; van Tongeren, Martie

    2012-01-01

    There are no recognized analytical methods for measuring oil mist and vapours arising from drilling fluids used in offshore petroleum drilling industry. To inform the future development of improved methods of analysis for oil mist and vapours this study assessed the inter- and intra-laboratory variability in oil mist and vapour analysis. In addition, sample losses during transportation and storage were assessed. Replicate samples for oil mist and vapour were collected using the 37-mm Millipore closed cassette and charcoal tube assembly. Sampling was conducted in a simulated shale shaker room, similar to that found offshore for processing drilling fluids. Samples were analysed at two different laboratories, one in Norway and one in the UK. Oil mist samples were analysed using Fourier transform infrared spectroscopy (FTIR), while oil vapour samples were analysed by gas chromatography (GC). The comparison of replicate samples showed substantial within- and between-laboratory variability in reported oil mist concentrations. The variability in oil vapour results was considerably reduced compared to oil mist, provided that a common method of calibration and quantification was adopted. The study also showed that losses can occur during transportation and storage of samples. There is a need to develop a harmonized method for the quantification of oil mist on filter and oil vapour on charcoal supported by a suitable proficiency testing scheme for laboratories involved in the analysis of occupational hygiene samples for the petroleum industry. The uncertainties in oil mist and vapour measurement have substantial implications in relation to compliance with occupational exposure limits and also in the reliability of any exposure-response information reported in epidemiological studies.

  19. Snake River Plain FORGE Well Data for USGS-142

    DOE Data Explorer

    Robert Podgorney

    2015-11-23

    Well data for the USGS-142 well located in eastern Snake River Plain, Idaho. This data collection includes lithology reports, borehole logs, and photos of rhyolite core samples. This collection of data has been assembled as part of the site characterization data used to develop the conceptual geologic model for the Snake River Plain site in Idaho, as part of phase 1 of the Frontier Observatory for Research in Geothermal Energy (FORGE) initiative. They were assembled by the Snake River Geothermal Consortium (SRGC), a team of collaborators that includes members from national laboratories, universities, industry, and federal agencies, lead by the Idaho National Laboratory (INL).

  20. Collecting, archiving and processing DNA from wildlife samples using FTA® databasing paper

    PubMed Central

    Smith, LM; Burgoyne, LA

    2004-01-01

    Background Methods involving the analysis of nucleic acids have become widespread in the fields of traditional biology and ecology, however the storage and transport of samples collected in the field to the laboratory in such a manner to allow purification of intact nucleic acids can prove problematical. Results FTA® databasing paper is widely used in human forensic analysis for the storage of biological samples and for purification of nucleic acids. The possible uses of FTA® databasing paper in the purification of DNA from samples of wildlife origin were examined, with particular reference to problems expected due to the nature of samples of wildlife origin. The processing of blood and tissue samples, the possibility of excess DNA in blood samples due to nucleated erythrocytes, and the analysis of degraded samples were all examined, as was the question of long term storage of blood samples on FTA® paper. Examples of the end use of the purified DNA are given for all protocols and the rationale behind the processing procedures is also explained to allow the end user to adjust the protocols as required. Conclusions FTA® paper is eminently suitable for collection of, and purification of nucleic acids from, biological samples from a wide range of wildlife species. This technology makes the collection and storage of such samples much simpler. PMID:15072582

  1. A Compact Laboratory Spectro-Goniometer (CLabSpeG) to Assess the BRDF of Materials. Presentation, Calibration and Implementation on Fagus sylvatica L. Leaves

    PubMed Central

    Biliouris, Dimitrios; Verstraeten, Willem W.; Dutré, Phillip; van Aardt, Jan A.N.; Muys, Bart; Coppin, Pol

    2007-01-01

    The design and calibration of a new hyperspectral Compact Laboratory Spectro-Goniometer (CLabSpeG) is presented. CLabSpeG effectively measures the bidirectional reflectance Factor (BRF) of a sample, using a halogen light source and an Analytical Spectral Devices (ASD) spectroradiometer. The apparatus collects 4356 reflectance data readings covering the spectrum from 350 nm to 2500 nm by independent positioning of the sensor, sample holder, and light source. It has an azimuth and zenith resolution of 30 and 15 degrees, respectively. CLabSpeG is used to collect BRF data and extract Bidirectional Reflectance Distribution Function (BRDF) data of non-isotropic vegetation elements such as bark, soil, and leaves. Accurate calibration has ensured robust geometric accuracy of the apparatus, correction for the conicality of the light source, while sufficient radiometric stability and repeatability between measurements are obtained. The bidirectional reflectance data collection is automated and remotely controlled and takes approximately two and half hours for a BRF measurement cycle over a full hemisphere with 125 cm radius and 2.4 minutes for a single BRF acquisition. A specific protocol for vegetative leaf collection and measurement was established in order to investigate the possibility to extract BRDF values from Fagus sylvatica L. leaves under laboratory conditions. Drying leaf effects induce a reflectance change during the BRF measurements due to the laboratory illumination source. Therefore, the full hemisphere could not be covered with one leaf. Instead 12 BRF measurements per leaf were acquired covering all azimuth positions for a single light source zenith position. Data are collected in radiance format and reflectance is calculated by dividing the leaf cycle measurement with a radiance cycle of a Spectralon reference panel, multiplied by a Spectralon reflectance correction factor and a factor to correct for the conical effect of the light source. BRF results of measured leaves are presented. PMID:28903201

  2. 2010 Groundwater Monitoring and Inspection Report Gnome-Coach Site, New Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2011-02-01

    This report presents the 2010 groundwater monitoring results collected by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) at the Gnome-Coach (Gnome) Site in New Mexico (Figure 1). Groundwater monitoring consisted of collecting hydraulic head data and groundwater samples from the wells on site. Historically, the U.S. Environmental Protection Agency (EPA) had conducted these annual activities under the Long-Term Hydrologic Monitoring Program (LTHMP). LM took over the sampling and data collection activities in 2008 but continues to use the EPA Radiation and Indoor Environments National Laboratory in Las Vegas, Nevada, to analyze the water samples. This reportmore » summarizes groundwater monitoring and site investigation activities that were conducted at the site during calendar year 2010.« less

  3. Use of on-site high performance liquid chromatography to evaluate the magnitude and extent of organic contaminants in aquifers

    USGS Publications Warehouse

    Goerlitz, D.F.; Franks, B.J.

    1989-01-01

    Appraisal of ground water contaminated by organic substances raises problems of difficult sample collection and timely chemical analysis. High-performance liquid chromatography was evaluated for on-site determination of specific organic contaminants in ground water samples and was used at three study sites. Organic solutes were determined directly in water samples, with little or no preparation, and usually in less than an hour after collection. This information improved sampling efficiency and was useful in screening for subsequent laboratory analysis. On two occasions, on-site analysis revealed that samples were undergoing rapid change, with major solutes being upgraded and alteration products being formed. In addition to sample stability, this technique proved valuable for monitoring other sampling factors such as compositional changes with respect to pumping, filtration, and cross contamination. -Authors

  4. Statistical analyses of the background distribution of groundwater solutes, Los Alamos National Laboratory, New Mexico.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Longmire, Patrick A.; Goff, Fraser; Counce, D. A.

    2004-01-01

    Background or baseline water chemistry data and information are required to distingu ish between contaminated and non-contaminated waters for environmental investigations conducted at Los Alamos National Laboratory (referred to as the Laboratory). The term 'background' refers to natural waters discharged by springs or penetrated by wells that have not been contaminated by LANL or other municipal or industrial activities, and that are representative of groundwater discharging from their respective aquifer material. These investigations are conducted as part of the Environmental Restoration (ER) Project, Groundwater Protection Program (GWPP), Laboratory Surveillance Program, the Hydrogeologic Workplan, and the Site-Wide Environmental Impact Statement (SWEIS).more » This poster provides a comprehensive, validated database of inorganic, organic, stable isotope, and radionuclide analyses of up to 136 groundwater samples collected from 15 baseline springs and wells located in and around Los Alamos National Laboratory, New Mexico. The region considered in this investigation extends from the western edge of the Jemez Mountains eastward to the Rio Grande and from Frijoles Canyon northward to Garcia Canyon. Figure 1 shows the fifteen stations sampled for this investigation. The sampling stations and associated aquifer types are summarized in Table 1.« less

  5. Vaginal Prostate Specific Antigen (PSA) Is a Useful Biomarker of Semen Exposure Among HIV-Infected Ugandan Women.

    PubMed

    Woolf-King, Sarah E; Muyindike, Winnie; Hobbs, Marcia M; Kusasira, Adrine; Fatch, Robin; Emenyonu, Nneka; Johnson, Mallory O; Hahn, Judith A

    2017-07-01

    The practical feasibility of using prostate specific antigen (PSA) as a biomarker of semen exposure was examined among HIV-infected Ugandan women. Vaginal fluids were obtained with self-collected swabs and a qualitative rapid test (ABAcard ® p30) was used to detect PSA. Trained laboratory technicians processed samples on-site and positive PSA tests were compared to self-reported unprotected vaginal sex (UVS) in the last 48 h. A total of 77 women submitted 126 samples for PSA testing at up to three study visits. Of these samples, 31 % (n = 39/126) were PSA positive, and 64 % (n = 25/39) of the positive PSA samples were accompanied by self-report of no UVS at the study visit the PSA was collected. There were no reported difficulties with specimen collection, storage, or processing. These findings provide preliminary data on high levels of misreported UVS among HIV-infected Ugandan women using practically feasible methods for PSA collection and processing.

  6. The Gulf Long-Term Follow-Up Study (GuLF STUDY): Biospecimen collection at enrollment.

    PubMed

    Engel, Lawrence S; Kwok, Richard K; Miller, Aubrey K; Blair, Aaron; Curry, Matthew D; McGrath, John A; Sandler, Dale P

    2017-01-01

    The 2010 Deepwater Horizon (DWH) explosion in the Gulf of Mexico led to the largest ever marine oil spill by volume. The GuLF STUDY is investigating possible adverse human health effects associated with oil spill activities. One objective of the study was to utilize biological specimens from study participants to examine spill-related adverse health effects. This study describes the methods for collecting, processing, shipping, and storing specimens during the enrollment phase of the study. GuLF STUDY participants living in Gulf States (Alabama, Florida, Louisiana, Mississippi, and eastern Texas) were eligible to complete a home visit at enrollment, one to three years after the DWH explosion. During this visit, blood, urine, toenail and hair clippings, and house dust samples were collected. Specimens were shipped overnight to a central processing laboratory in containers with cold and ambient temperature compartments. Most blood and urine specimens were then aliquoted and stored in liquid nitrogen vapor or at -80°C, with some samples stored at -20°C. A total of 11,193 participants completed a home visit, and over 99% provided at least one biospecimen. Most participants provided blood (93%), urine (99%), and toenail clippings (89%), and 40% provided hair. Nearly all participants (95%) provided house-dust samples. Most samples were received by the laboratory one (58%) or two (25%) days after collection. These biospecimens enable investigation of a range of biomarkers of spill-related adverse health effects, and possibly some biomarkers of spill-related exposures. The biospecimen collection, handling, and storage protocols were designed to maximize current and future scientific value within logistical and budgetary constraints and might serve as a template for future studies conducted in similar time-critical and geographically dispersed settings.

  7. Addendum to Sampling and Analysis Plan (SAP) for Assessment of LANL-Derived Residual Radionuclides in Soils within Tract A-16-d for Land Conveyance and Transfer for Sewage Treatment Facility Area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whicker, Jeffrey Jay; Gillis, Jessica Mcdonnel; Ruedig, Elizabeth

    This report summarizes the sampling design used, associated statistical assumptions, as well as general guidelines for conducting post-sampling data analysis. Sampling plan components presented here include how many sampling locations to choose and where within the sampling area to collect those samples. The type of medium to sample (i.e., soil, groundwater, etc.) and how to analyze the samples (in-situ, fixed laboratory, etc.) are addressed in other sections of the sampling plan.

  8. Evaluation of the Sequential Spot Sampler (S3) for time-resolved measurement of PM2.5 sulfate and nitrate through lab and field measurements

    NASA Astrophysics Data System (ADS)

    Hecobian, A.; Evanoski-Cole, A.; Eiguren-Fernandez, A.; Sullivan, A. P.; Lewis, G. S.; Hering, S. V.; Collett, J. L., Jr.

    2016-02-01

    The Sequential Spot Sampler (S3), a newly developed instrument to collect aerosols for time-resolved chemical composition measurements, was evaluated in the laboratory and field for the measurement of particulate sulfate and nitrate. The S3 uses a multi-temperature condensation growth tube to grow individual aerosols to droplets which are then deposited as a ˜ 1 mm diameter dry spot at the end of the growth tube in a 100 µL well of a multi-well plate. The well plate advances automatically to provide a sequence of time-resolved samples. The collected aerosols are subsequently analyzed in the laboratory. The sample is concentrated during the collection process, and the laboratory extraction and analysis steps can be automated. The well plate, as received from the field, is placed onto a needle-based autosampler that adds liquid for sample extraction and injects sample extract from each well onto an ion chromatograph for analysis. Laboratory evaluation for sulfate and nitrate ions showed that poly ether ether ketone (PEEK) used as well plate material does not contribute any artifacts; a 60 min extraction procedure leads to the recovery of sulfate and nitrate from the dry spots at above 95 % extraction efficiency; and samples stored frozen and analyzed up to 23 months later show less than a 10 % change in sulfate and nitrate concentrations. The limit of detection was 0.5 µg m-3 for sulfate and 0.2 µg m-3 for nitrate for a 1 h sampling period. In a month-long field study conducted in southern California, two S3s were deployed alongside a URG denuder-filter-pack and a Particle-Into-Liquid Sampler combined with an Ion Chromatograph (PILS-IC). Collocated S3 sampler concentrations compared by linear regression show good agreement, with r2 = 0.99 and slope = 0.99 (±0.004) µg m-3 for sulfate and r2 = 0.99 and slope = 1.0 (±0.006) µg m-3 for nitrate. When compared to the URG denuder-filter-pack and the PILS-IC, the S3 sulfate and nitrate concentrations yielded correlations above 0.84 for the square of the correlation coefficient and regression slopes close to 1.

  9. In Situ Raman Analyses of Natural Gas and Gas Hydrates at Hydrate Ridge, Oregon

    NASA Astrophysics Data System (ADS)

    Peltzer, E. T.; White, S. N.; Dunk, R. M.; Brewer, P. G.; Sherman, A. D.; Schmidt, K.; Hester, K. C.; Sloan, E. D.

    2004-12-01

    During a July 2004 cruise to Hydrate Ridge, Oregon, MBARI's sea-going laser Raman spectrometer was used to obtain in situ Raman spectra of natural gas hydrates and natural gas venting from the seafloor. This was the first in situ analysis of gas hydrates on the seafloor. The hydrate spectra were compared to laboratory analyses performed at the Center for Hydrate Research, Colorado School of Mines. The natural gas spectra were compared to MBARI gas chromatography (GC) analyses of gas samples collected at the same site. DORISS (Deep Ocean Raman In Situ Spectrometer) is a laboratory model laser Raman spectrometer from Kaiser Optical Systems, Inc modified at MBARI for deployment in the deep ocean. It has been successfully deployed to depths as great as 3600 m. Different sampling optics provide flexibility in adapting the instrument to a particular target of interest. An immersion optic was used to analyze natural gas venting from the seafloor at South Hydrate Ridge ( ˜780 m depth). An open-bottomed cube was placed over the vent to collect the gas. The immersion optic penetrated the side of the cube as did a small heater used to dissociate any hydrate formed during sample collection. To analyze solid hydrates at both South and North Hydrate Ridge ( ˜590 m depth), chunks of hydrate were excavated from the seafloor and collected in a glass cylinder with a mesh top. A stand-off optic was used to analyze the hydrate inside the cylinder. Due to the partial opacity of the hydrate and the small focal volume of the sampling optic, a precision underwater positioner (PUP) was used to focus the laser spot onto the hydrate. PUP is a stand-alone system with three degrees-of-freedom, capable of moving the DORISS probe head with a precision of 0.1 mm. In situ Raman analyses of the gas indicate that it is primarily methane. This is verified by GC analyses of samples collected from the same site. Other minor constituents (such as CO2 and higher hydrocarbons) are present but may be in concentrations too low to be detected by the current DORISS instrument. In situ analyses of the hydrates show them to be structure I hydrates with methane as the primary guest molecule; the data compare well to laboratory data.

  10. Development of a low background liquid scintillation counter for a shallow underground laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erchinger, Jennifer L.; Aalseth, Craig E.; Bernacki, Bruce E.

    2015-08-20

    Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of lowconcentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillation counting is especially useful for measuring charged particle (e.g., B, a) emitting isotopes with no (orvery weak) gamma-ray yields. The combination of high-efficiency detection of charged particle emission in a liquid scintillation cocktail coupled with the low-background environment of an appropriately-designed shield located in a clean underground laboratory provides the opportunitymore » for increased-sensitivity measurements of a range of isotopes. To take advantage of the 35-meter water-equivalent overburden of the underground laboratory, a series of simulations have evaluated the instrumental shield design requirements to assess the possible background rate achievable. This report presents the design and background evaluation for a shallow underground, low background liquid scintillation counter design for sample measurements.« less

  11. Time-integrated sampling of fluvial suspended sediment: a simple methodology for small catchments

    NASA Astrophysics Data System (ADS)

    Phillips, J. M.; Russell, M. A.; Walling, D. E.

    2000-10-01

    Fine-grained (<62·5 µm) suspended sediment transport is a key component of the geochemical flux in most fluvial systems. The highly episodic nature of suspended sediment transport imposes a significant constraint on the design of sampling strategies aimed at characterizing the biogeochemical properties of such sediment. A simple sediment sampler, utilizing ambient flow to induce sedimentation by settling, is described. The sampler can be deployed unattended in small streams to collect time-integrated suspended sediment samples. In laboratory tests involving chemically dispersed sediment, the sampler collected a maximum of 71% of the input sample mass. However, under natural conditions, the existence of composite particles or flocs can be expected to increase significantly the trapping efficiency. Field trials confirmed that the particle size composition and total carbon content of the sediment collected by the sampler were representative statistically of the ambient suspended sediment.

  12. Comparison of the Sensitivity of Laboratory Diagnostic Methods from a Well-Characterized Outbreak of Mumps in New York City in 2009

    PubMed Central

    Rosen, Jennifer B.; Doll, Margaret K.; McNall, Rebecca J.; McGrew, Marcia; Williams, Nobia; Lopareva, Elena N.; Barskey, Albert E.; Punsalang, Amado; Rota, Paul A.; Oleszko, William R.; Hickman, Carole J.; Zimmerman, Christopher M.; Bellini, William J.

    2013-01-01

    A mumps outbreak in upstate New York in 2009 at a summer camp for Orthodox Jewish boys spread into Orthodox Jewish communities in the Northeast, including New York City. The availability of epidemiologic information, including vaccination records and parotitis onset dates, allowed an enhanced analysis of laboratory methods for mumps testing. Serum and buccal swab samples were collected from 296 confirmed cases with onsets from September through December 2009. All samples were tested using the Centers for Disease Control and Prevention (CDC) capture IgM enzyme immunoassay (EIA) and a real-time reverse transcription-PCR (rRT-PCR) that targets the short hydrophobic gene. A subset of the samples (n = 205) was used to evaluate 3 commercial mumps IgM assays and to assess the sensitivity of using an alternative target gene (nucleoprotein) in the rRT-PCR protocol. Among 115 cases of mumps with 2 documented doses of measles, mumps, and rubella (MMR) vaccine, the CDC capture IgM EIA detected IgM in 51% of serum samples compared to 9% to 24% using three commercial IgM assays. The rRT-PCR that targeted the nucleoprotein gene increased RNA detection by 14% compared to that obtained with the original protocol. The ability to detect IgM improved when serum was collected 3 days or more after symptom onset, whereas sensitivity of RNA detection by rRT-PCR declined when buccal swabs were collected later than 2 days after onset. Selection of testing methods and timing of sample collection are important factors in the ability to confirm infection among vaccinated persons. These results reinforce the need to use virus detection assays in addition to serologic tests. PMID:23324519

  13. Microbiological Values of Rainwater Harvested in Adelaide

    PubMed Central

    Edwards, John W.

    2018-01-01

    In Australia, rainwater is an important source of water for many households. Unlike municipal water, rainwater is often consumed untreated. This study investigated the potential contamination of rainwater by microorganisms. Samples from 53 rainwater tanks across the Adelaide region were collected and tested using Colilert™ IDEXX Quanti-Tray*/2000. Twenty-eight out of the 53 tanks (53%) contained Escherichia coli. Samples collected from ten tanks contained E. coli at concentrations exceeding the limit of 150 MPN/100 mL for recreational water quality. A decline in E. coli was observed in samples collected after prolonged dry periods. Rainwater microbiological values depended on the harvesting environment conditions. A relationship was found between mounted TV antenna on rooftops and hanging canopies; and E. coli abundance. Conversely, there was no relationship between seasonality and E. coli or roof and tank structure materials and E. coli. In several tanks used for drinking water, samples collected prior to and after filtration showed that the filtration systems were not always successful at completely removing E. coli. These results differed from a study undertaken in the laboratory that found that a commercially available in-bench 0.45 µm filter cartridge successfully reduced E. coli in rainwater to 0 MPN/100 mL. After running a total of 265 L of rainwater which contained high levels of E. coli through the filter (half of the advertised filter lifespan), the filter cartridge became blocked, although E. coli remained undetected in filtered water. The difference between the laboratory study and field samples could be due to improper maintenance or installation of filters or recontamination of the faucet after filtration. The presence of E. coli in water that is currently used for drinking poses a potential health concern and indicates the potential for contamination with other waterborne pathogens. PMID:29419793

  14. A new laboratory-based surveillance system (Respiratory DataMart System) for influenza and other respiratory viruses in England: results and experience from 2009 to 2012.

    PubMed

    Zhao, H; Green, H; Lackenby, A; Donati, M; Ellis, J; Thompson, C; Bermingham, A; Field, J; Sebastianpillai, P; Zambon, M; Watson, Jm; Pebody, R

    2014-01-23

    During the 2009 influenza A(H1N1) pandemic, a new laboratory-based virological sentinel surveillance system, the Respiratory DataMart System (RDMS), was established in a network of 14 Health Protection Agency (now Public Health England (PHE)) and National Health Service (NHS) laboratories in England. Laboratory results (both positive and negative) were systematically collected from all routinely tested clinical respiratory samples for a range of respiratory viruses including influenza, respiratory syncytial virus (RSV), rhinovirus, parainfluenza virus, adenovirus and human metapneumovirus (hMPV). The RDMS also monitored the occurrence of antiviral resistance of influenza viruses. Data from the RDMS for the 2009–2012 period showed that the 2009 pandemic influenza virus caused three waves of activity with different intensities during the pandemic and post pandemic periods. Peaks in influenza A(H1N1)pdm09 positivity (defined as number of positive samples per total number of samples tested) were seen in summer and autumn in 2009, with slightly higher peak positivity observed in the first post-pandemic season in 2010/2011. The influenza A(H1N1)pdm09 virus strain almost completely disappeared in the second postpandemic season in 2011/2012. The RDMS findings are consistent with other existing community-based virological and clinical surveillance systems. With a large sample size, this new system provides a robust supplementary mechanism, through the collection of routinely available laboratory data at minimum extra cost, to monitor influenza as well as other respiratory virus activity. A near real-time, daily reporting mechanism in the RDMS was established during the London 2012 Olympic and Paralympic Games. Furthermore, this system can be quickly adapted and used to monitor future influenza pandemics and other major outbreaks of respiratory infectious disease, including novel pathogens.

  15. An innovative tool for moving malaria PCR detection of parasite reservoir into the field

    PubMed Central

    2013-01-01

    Background To achieve the goal of malaria elimination in low transmission areas such as in Cambodia, new, inexpensive, high-throughput diagnostic tools for identifying very low parasite densities in asymptomatic carriers are required. This will enable a switch from passive to active malaria case detection in the field. Methods DNA extraction and real-time PCR assays were implemented in an “in-house” designed mobile laboratory allowing implementation of a robust, sensitive and rapid malaria diagnostic strategy in the field. This tool was employed in a survey organized in the context of the MalaResT project (NCT01663831). Results The real-time PCR screening and species identification assays were performed in the mobile laboratory between October and November 2012, in Rattanakiri Province, to screen approximately 5,000 individuals in less than four weeks and treat parasite carriers within 24–48 hours after sample collection. An average of 240 clinical samples (and 40 quality control samples) was tested every day, six/seven days per week. Some 97.7% of the results were available <24 hours after the collection. A total of 4.9% were positive for malaria. Plasmodium vivax was present in 61.1% of the positive samples, Plasmodium falciparum in 45.9%, Plasmodium malariae in 7.0% and Plasmodium ovale in 2.0%. Conclusions The operational success of this diagnostic set-up proved that molecular testing and subsequent treatment is logistically achievable in field settings. This will allow the detection of clusters of asymptomatic carriers and to provide useful epidemiological information. Fast results will be of great help for staff in the field to track and treat asymptomatic parasitaemic cases. The concept of the mobile laboratory could be extended to other countries for the molecular detection of malaria or other pathogens, or to culture vivax parasites, which does not support long-time delay between sample collection and culture. PMID:24206649

  16. Environmental assessment of creosote-treated pilings in the marine environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butala, J.H.; Webb, D.A.; Jop, K.M.

    1995-12-31

    A comprehensive ecological risk assessment was conducted to evaluate the environmental impact of creosote-treated pilings in the marine environment at Moss Landing Harbor, Moss Landing, California. Four areas of investigation comprising the risk assessment were (1) evaluation of environmental conditions around existing creosote-treated pilings (2) investigating effects related to restoration of pilings (3) assessing creosote migration into surrounding environment, one year after pile-driving and (4) confirmation of creosote toxicity in laboratory studies. Biological and chemical evaluation of the impact of creosote-treated pilings was conducted on surface sheen, water column and sediment samples collected at Moss Landing Harbor. Water samples (surfacemore » sheen, water column and sediment pore water) were evaluated using short-term chronic exposures with Mysidopsis bahia, while bulk sediment samples were evaluated with 10-day sediment toxicity tests with Ampelisca abdita. Samples of surface, column water and sediment were analyzed for the constituents of creosote by GC mass spectrometry. In addition, a sample of neat material used to preserve treated pilings represented a reference for the polyaromatic hydrocarbons. Verification of organism response and analyses of field collected samples was performed by conducting 10-day A. abdita sediment and 7-day M. bahia elutriate exposures with creosote applied to clean sediment collected at Moss Landing, Evaluations were also performed to determine the effects of photoinduced toxicity on test organisms exposed to PAHs. The biological and analytical results of the field and laboratory exposures are being used to evaluate and determine risk of creosote-treated pilings on the marine environment.« less

  17. Harpoon-based sample Acquisition System

    NASA Astrophysics Data System (ADS)

    Bernal, Javier; Nuth, Joseph; Wegel, Donald

    2012-02-01

    Acquiring information about the composition of comets, asteroids, and other near Earth objects is very important because they may contain the primordial ooze of the solar system and the origins of life on Earth. Sending a spacecraft is the obvious answer, but once it gets there it needs to collect and analyze samples. Conceptually, a drill or a shovel would work, but both require something extra to anchor it to the comet, adding to the cost and complexity of the spacecraft. Since comets and asteroids are very low gravity objects, drilling becomes a problem. If you do not provide a grappling mechanism, the drill would push the spacecraft off the surface. Harpoons have been proposed as grappling mechanisms in the past and are currently flying on missions such as ROSETTA. We propose to use a hollow, core sampling harpoon, to act as the anchoring mechanism as well as the sample collecting device. By combining these two functions, mass is reduced, more samples can be collected and the spacecraft can carry more propellant. Although challenging, returning the collected samples to Earth allows them to be analyzed in laboratories with much greater detail than possible on a spacecraft. Also, bringing the samples back to Earth allows future generations to study them.

  18. Marine anthropogenic radiotracers in the Southern Hemisphere: New sampling and analytical strategies

    NASA Astrophysics Data System (ADS)

    Levy, I.; Povinec, P. P.; Aoyama, M.; Hirose, K.; Sanchez-Cabeza, J. A.; Comanducci, J.-F.; Gastaud, J.; Eriksson, M.; Hamajima, Y.; Kim, C. S.; Komura, K.; Osvath, I.; Roos, P.; Yim, S. A.

    2011-04-01

    The Japan Agency for Marine Earth Science and Technology conducted in 2003-2004 the Blue Earth Global Expedition (BEAGLE2003) around the Southern Hemisphere Oceans, which was a rare opportunity to collect many seawater samples for anthropogenic radionuclide studies. We describe here sampling and analytical methodologies based on radiochemical separations of Cs and Pu from seawater, as well as radiometric and mass spectrometry measurements. Several laboratories took part in radionuclide analyses using different techniques. The intercomparison exercises and analyses of certified reference materials showed a reasonable agreement between the participating laboratories. The obtained data on the distribution of 137Cs and plutonium isotopes in seawater represent the most comprehensive results available for the Southern Hemisphere Oceans.

  19. Veterinary Forensic Toxicology.

    PubMed

    Gwaltney-Brant, S M

    2016-09-01

    Veterinary pathologists working in diagnostic laboratories are sometimes presented with cases involving animal poisonings that become the object of criminal or civil litigation. Forensic veterinary toxicology cases can include cases involving animal cruelty (malicious poisoning), regulatory issues (eg, contamination of the food supply), insurance litigation, or poisoning of wildlife. An understanding of the appropriate approach to these types of cases, including proper sample collection, handling, and transport, is essential so that chain of custody rules are followed and proper samples are obtained for toxicological analysis. Consultation with veterinary toxicologists at the diagnostic laboratory that will be processing the samples before, during, and after the forensic necropsy can help to ensure that the analytical tests performed are appropriate for the circumstances and findings surrounding the individual case. © The Author(s) 2016.

  20. Comparative value of blood and skin samples for diagnosis of spotted fever group rickettsial infection in model animals.

    PubMed

    Levin, Michael L; Snellgrove, Alyssa N; Zemtsova, Galina E

    2016-07-01

    The definitive diagnosis of spotted fever group (SFG) rickettsioses in humans is challenging due to the retrospective nature and cross reactivity of the serological methods and the absence of reliable and consistent samples for molecular diagnostics. Existing data indicate the transient character of bacteremia in experimentally infected animals. The ability of arthropod vectors to acquire rickettsial infection from the laboratory animals in the absence of systemic infection and known tropism of rickettsial agents to endothelial cells of peripheral blood vessels underline the importance of local infection and consequently the diagnostic potential of skin samples. In order to evaluate the diagnostic sensitivity of rickettsial DNA detection in blood and skin samples, we compared results of PCR testing in parallel samples collected from model laboratory animals infected with Rickettsia rickettsii, Rickettsia parkeri and Rickettsia slovaca-like agent at different time points after infection. Skin samples were collected from ears - away from the site of tick placement and without eschars. Overall, testing of skin samples resulted in a higher proportion of positive results than testing of blood samples. Presented data from model animals demonstrates that testing of skin samples from sites of rickettsial proliferation can provide definitive molecular diagnosis of up to 60-70% of tick-borne SFG rickettsial infections during the acute stage of illness. Detection of pathogen DNA in cutaneous samples is a valuable alternative to blood-PCR at least in model animals. Published by Elsevier GmbH.

  1. FIELD TRAPPING OF SUBSURFACE VAPOR PHASE PETROLEUM HYDROCARBONS

    EPA Science Inventory

    Soil gas samples from intact soil cores were collected on adsorbents at a field site, then thermally desorbed and analyzed by laboratory gas chromatography (GC). ertical concentration profiles of predominant vapor phase petroleum hydrocarbons under ambient conditions were obtaine...

  2. Wakata prepares for Surface Sample Kit (SSK) Collection/Incubation

    NASA Image and Video Library

    2009-04-29

    ISS019-E-012393 (29 April 2009) --- Japan Aerospace Exploration Agency (JAXA) astronaut Koichi Wakata, Expedition 19/20 flight engineer, is pictured near a Microbial Air Sampler floating freely in the Kibo laboratory of the International Space Station.

  3. RAPID ON-SITE METHODS OF CHEMICAL ANALYSIS

    EPA Science Inventory

    The analysis of potentially hazardous air, water and soil samples collected and shipped to service laboratories off-site is time consuming and expensive. This Chapter addresses the practical alternative of performing the requisite analytical services on-site. The most significant...

  4. External quality-assurance programs managed by the U.S. Geological Survey in support of the National Atmospheric Deposition Program/National Trends Network

    USGS Publications Warehouse

    Latysh, Natalie E.; Wetherbee, Gregory A.

    2005-01-01

    The U.S. Geological Survey, Branch of Quality Systems, operates the external quality-assurance programs for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN). Beginning in 1978, six different programs have been implemented?the intersite-comparison program, the blind-audit program, the sample-handling evaluation program, the field-audit program, the interlaboratory-comparison program, and the collocated-sampler program. Each program was designed to measure error contributed by specific components in the data-collection process. The intersite-comparison program, which was discontinued in 2004, was designed to assess the accuracy and reliability of field pH and specific-conductance measurements made by site operators. The blind-audit and sample-handling evaluation programs, which also were discontinued in 2002 and 2004, respectively, assessed contamination that may result from sampling equipment and routine handling and processing of the wet-deposition samples. The field-audit program assesses the effects of sample handling, processing, and field exposure. The interlaboratory-comparison program evaluates bias and precision of analytical results produced by the contract laboratory for NADP, the Illinois State Water Survey, Central Analytical Laboratory, and compares its performance with the performance of international laboratories. The collocated-sampler program assesses the overall precision of wet-deposition data collected by NADP/NTN. This report documents historical operations and the operating procedures for each of these external quality-assurance programs. USGS quality-assurance information allows NADP/NTN data users to discern between actual environmental trends and inherent measurement variability.

  5. Randomised controlled trial of whether erotic material is required for semen collection: impact of informed consent on outcome.

    PubMed

    Handelsman, D J; Sivananathan, T; Andres, L; Bathur, F; Jayadev, V; Conway, A J

    2013-11-01

    Semen is collected to evaluate male fertility or cryostore sperm preferentially in laboratories but such collection facilities have no standard fit-out. It is widely believed but untested whether providing erotic material (EM) is required to collect semen by masturbation in the unfamiliar environment. To test this assumption, 1520 men (1046 undergoing fertility evaluation, 474 sperm cryostorage, providing 1932 semen collection episodes) consecutively attending the semen laboratory of a major metropolitan teaching hospital for semen analysis were eligible for randomization to be provided or not with printed erotic material EM (X-rated, soft-core magazines) during semen collection. Randomization was performed by providing magazines in the collection rooms (as a variation on non-standard fit-out) on alternate weeks using a schedule concealed from participants. In the pilot study, men were randomized without seeking consent. In the second part of the study, which continued on from the first without interruption, an approved informed consent procedure was added. The primary outcome, the time to collect semen defined as the time from receiving to returning the sample receptacle, was significantly longer (by ~6%, 14.9 ± 0.3 [mean ± standard error of mean] vs. 14.0 ± 0.2 minutes, p = 0.02) among men provided with EM than those randomized to not being provided. There was no significant increase in the failure to collect semen samples (2.6% overall) nor any difference in age, semen volume or sperm concentration, output or motility according to whether EM was provided or not. The significantly longer time to collect was evident in the pilot study and the study overall, but not in the main study where the informed consent procedure was used. This study provides evidence that refutes the assumption that EM needs to be provided for semen collection in a laboratory. It also provides an example of a usually unobservable participation bias influencing study outcome of a randomized controlled trials. © 2013 American Society of Andrology and European Academy of Andrology.

  6. Geology-based method of assessing sensitivity of streams to acidic deposition in Charles and Anne Arundel Counties, Maryland

    USGS Publications Warehouse

    Rice, Karen C.; Bricker, Owen P.

    1991-01-01

    The report describes the results of a study to assess the sensitivity of streams to acidic deposition in Charles and Anne Arundel Counties, Maryland using a geology-based method. Water samples were collected from streams in July and August 1988 when streams were at base-flow conditions. Eighteen water samples collected from streams in Charles County, and 17 water samples from streams in Anne Arundel County were analyzed in the field for pH, specific conductance, and acid-neutralizing capacity (ANC); 8 water samples from streams in Charles County were analyzed in the laboratory for chloride and sulfate concentrations. The assessment revealed that streams in these counties are sensitive to acidification by acidic deposition.

  7. Validity of a portable glucose, total cholesterol, and triglycerides multi-analyzer in adults.

    PubMed

    Coqueiro, Raildo da Silva; Santos, Mateus Carmo; Neto, João de Souza Leal; Queiroz, Bruno Morbeck de; Brügger, Nelson Augusto Jardim; Barbosa, Aline Rodrigues

    2014-07-01

    This study investigated the accuracy and precision of the Accutrend Plus system to determine blood glucose, total cholesterol, and plasma triglycerides in adults and evaluated its efficiency in measuring these blood variables. The sample consisted of 53 subjects (≥ 18 years). For blood variable laboratory determination, venous blood samples were collected and processed in a Labmax 240 analyzer. To measure blood variables with the Accutrend Plus system, samples of capillary blood were collected. In the analysis, the following tests were included: Wilcoxon and Student's t-tests for paired samples, Lin's concordance coefficient, Bland-Altman method, receiver operating characteristic curve, McNemar test, and k statistics. The results show that the Accutrend Plus system provided significantly higher values (p ≤ .05) of glucose and triglycerides but not of total cholesterol (p > .05) as compared to the values determined in the laboratory. However, the system showed good reproducibility (Lin's coefficient: glucose = .958, triglycerides = .992, total cholesterol = .940) and high concordance with the laboratory method (Lin's coefficient: glucose = .952, triglycerides = .990, total cholesterol = .944) and high sensitivity (glucose = 80.0%, triglycerides = 90.5%, total cholesterol = 84.4%) and specificity (glucose = 100.0%, triglycerides = 96.9%, total cholesterol = 95.2%) in the discrimination of high values of the three blood variables analyzed. It could be concluded that despite the tendency to overestimate glucose and triglyceride levels, a portable multi-analyzer is a valid alternative for the monitoring of metabolic disorders and cardiovascular risk factors. © The Author(s) 2013.

  8. The perceived and actual diagnostic utility of veterinary cytological samples.

    PubMed

    Skeldon, N; Dewhurst, E

    2009-04-01

    To establish the proportion of cytology samples sent to a commercial veterinary laboratory that yields diagnostically useful information in the context of current use and perceptions of cytology. Nine hundred and forty-five cytology submissions were retrospectively collected and categorised according to diagnostic utility. A survey into the use and perceptions of cytology was distributed at the British Small Animal Veterinary Association Congress 2008. A specific diagnosis was reached in 23.1 per cent of samples and a cytological diagnosis in 35.3 per cent. 22.4 per cent of samples yielded some useful information, but 19.2 per cent were unacceptable. Seventy-four participants in the survey took an average of 3.9 cytological samples per week, of which they examined 27.0 per cent in-house only, 21.6 per cent in-house before sending to an external laboratory and 51.4 per cent were sent externally without prior examination. "To obtain a definitive diagnosis" was the principal reason cited for performing cytology. Results suggest that cytology is underused and may be applied in an inappropriate context in the UK. It is hoped that illustrating the diagnostic outcome of samples received by a commercial laboratory will encourage increased, appropriate use of cytology.

  9. Use of proficiency samples to assess diagnostic laboratories in France performing a Trichinella digestion assay.

    PubMed

    Vallée, Isabelle; Macé, Pauline; Forbes, Lorry; Scandrett, Brad; Durand, Benoit; Gajadhar, Alvin; Boireau, Pascal

    2007-07-01

    Routine diagnosis of animal trichinellosis for food safety and trade relies on a method of artificial digestion to free Trichinella muscle larvae from meat for subsequent identification by microscopy. As part of a quality control system, the French National Reference Laboratory (NRL) initiated ring trials to determine the sensitivity of the test performed in the 72 routine diagnostic laboratories in France. A method was devised to obtain calibrated meat samples containing known numbers of capsules with Trichinella spiralis muscle larvae. This method was based on an incomplete artificial digestion of Trichinella-infected mice carcasses to allow the collection of intact Trichinella capsules. Capsules were placed into a meatball of 100 +/- 2 g of pork and horsemeat to produce proficiency samples. Three categories of samples were prepared: small (3 to 5 capsules), medium (7 to 10), and large (12 to 15). The sensitivity was expressed as the percentage of muscle larvae recovered from each proficiency sample. Reproducibility was tested with ring trials organized between two NRLs (France and Canada), and a reference sensitivity of 84.9% was established. National ring trials were then organized in France, with the 72 routine diagnostic laboratories each receiving four proficiency samples per session. After five sessions, an improvement in the digest test sensitivity was observed. Results at the fifth session indicated sensitivities of 78.60% +/- 23.70%, 81.19% +/- 19.59%, and 80.52% +/- 14.71% muscle larvae for small, medium, and large samples, respectively. This study supports the use of proficiency samples to accurately evaluate the performance of routine diagnostic laboratories that conduct digestion tests for animal trichinellosis diagnosis.

  10. Final Reports of the Stardust ISPE: Seven Probable Interstellar Dust Particles

    NASA Technical Reports Server (NTRS)

    Allen, Carlton; Sans Tresseras, Juan-Angel; Westphal, Andrew J.; Stroud, Rhonda M.; Bechtel, Hans A.; Brenker, Frank E.; Butterworth, Anna L.; Flynn, George J.; Frank, David R.; Gainsforth, Zack; hide

    2014-01-01

    The Stardust spacecraft carried the first spaceborne collector specifically designed to capture and return a sample of contemporary interstellar dust to terrestrial laboratories for analysis [1]. The collector was exposed to the interstellar dust stream in two periods in 2000 and 2002 with a total exposure of approximately 1.8 10(exp 6) square meters sec. Approximately 85% of the collector consisted of aerogel, and the remainder consisted of Al foils. The Stardust Interstellar Preliminary Examination (ISPE) was a consortiumbased effort to characterize the collection in sufficient detail to enable future investigators to make informed sample requests. Among the questions to be answered were these: How many impacts are consistent in their characteristics with interstellar dust, with interplanetary dust, and with secondary ejecta from impacts on the spacecraft? Are the materials amorphous or crystalline? Are organics detectable? An additional goal of the ISPE was to develop or refine the techniques for preparation, analysis, and curation of these tiny samples, expected to be approximately 1 picogram or smaller, roughly three orders of magnitude smaller in mass than the samples in other small particle collections in NASA's collections - the cometary samples returned by Stardust, and the collection of Interplanetary Dust Particles collected in the stratosphere.

  11. Sampling and analysis method for measuring airborne coal dust mass in mixtures with limestone (rock) dust.

    PubMed

    Barone, T L; Patts, J R; Janisko, S J; Colinet, J F; Patts, L D; Beck, T W; Mischler, S E

    2016-01-01

    Airborne coal dust mass measurements in underground bituminous coal mines can be challenged by the presence of airborne limestone dust, which is an incombustible dust applied to prevent the propagation of dust explosions. To accurately measure the coal portion of this mixed airborne dust, the National Institute for Occupational Safety and Health (NIOSH) developed a sampling and analysis protocol that used a stainless steel cassette adapted with an isokinetic inlet and the low temperature ashing (LTA) analytical method. The Mine Safety and Health Administration (MSHA) routinely utilizes this LTA method to quantify the incombustible content of bulk dust samples collected from the roof, floor, and ribs of mining entries. The use of the stainless steel cassette with isokinetic inlet allowed NIOSH to adopt the LTA method for the analysis of airborne dust samples. Mixtures of known coal and limestone dust masses were prepared in the laboratory, loaded into the stainless steel cassettes, and analyzed to assess the accuracy of this method. Coal dust mass measurements differed from predicted values by an average of 0.5%, 0.2%, and 0.1% for samples containing 20%, 91%, and 95% limestone dust, respectively. The ability of this method to accurately quantify the laboratory samples confirmed the validity of this method and allowed NIOSH to successfully measure the coal fraction of airborne dust samples collected in an underground coal mine.

  12. Sampling and analysis method for measuring airborne coal dust mass in mixtures with limestone (rock) dust

    PubMed Central

    Barone, T. L.; Patts, J. R.; Janisko, S. J.; Colinet, J. F.; Patts, L. D.; Beck, T. W.; Mischler, S. E.

    2016-01-01

    Airborne coal dust mass measurements in underground bituminous coal mines can be challenged by the presence of airborne limestone dust, which is an incombustible dust applied to prevent the propagation of dust explosions. To accurately measure the coal portion of this mixed airborne dust, the National Institute for Occupational Safety and Health (NIOSH) developed a sampling and analysis protocol that used a stainless steel cassette adapted with an isokinetic inlet and the low temperature ashing (LTA) analytical method. The Mine Safety and Health Administration (MSHA) routinely utilizes this LTA method to quantify the incombustible content of bulk dust samples collected from the roof, floor, and ribs of mining entries. The use of the stainless steel cassette with isokinetic inlet allowed NIOSH to adopt the LTA method for the analysis of airborne dust samples. Mixtures of known coal and limestone dust masses were prepared in the laboratory, loaded into the stainless steel cassettes, and analyzed to assess the accuracy of this method. Coal dust mass measurements differed from predicted values by an average of 0.5%, 0.2%, and 0.1% for samples containing 20%, 91%, and 95% limestone dust, respectively. The ability of this method to accurately quantify the laboratory samples confirmed the validity of this method and allowed NIOSH to successfully measure the coal fraction of airborne dust samples collected in an underground coal mine. PMID:26618374

  13. Recent developments and future trends in solid phase microextraction techniques towards green analytical chemistry.

    PubMed

    Spietelun, Agata; Marcinkowski, Łukasz; de la Guardia, Miguel; Namieśnik, Jacek

    2013-12-20

    Solid phase microextraction find increasing applications in the sample preparation step before chromatographic determination of analytes in samples with a complex composition. These techniques allow for integrating several operations, such as sample collection, extraction, analyte enrichment above the detection limit of a given measuring instrument and the isolation of analytes from sample matrix. In this work the information about novel methodological and instrumental solutions in relation to different variants of solid phase extraction techniques, solid-phase microextraction (SPME), stir bar sorptive extraction (SBSE) and magnetic solid phase extraction (MSPE) is presented, including practical applications of these techniques and a critical discussion about their advantages and disadvantages. The proposed solutions fulfill the requirements resulting from the concept of sustainable development, and specifically from the implementation of green chemistry principles in analytical laboratories. Therefore, particular attention was paid to the description of possible uses of novel, selective stationary phases in extraction techniques, inter alia, polymeric ionic liquids, carbon nanotubes, and silica- and carbon-based sorbents. The methodological solutions, together with properly matched sampling devices for collecting analytes from samples with varying matrix composition, enable us to reduce the number of errors during the sample preparation prior to chromatographic analysis as well as to limit the negative impact of this analytical step on the natural environment and the health of laboratory employees. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Tank Vapor Characterization Project: Tank 241-S-102 fourth temporal study: Headspace gas and vapor characterization results from samples collected on December 19, 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pool, K.H.; Evans, J.C.; Olsen, K.B.

    1997-08-01

    This report presents the results from analyses of samples taken from the headspace of waste storage tank 241-S-102 (Tank S-102) at the Hanford Site in Washington State. Tank headspace samples collected by SGN Eurisys Service Corporation (SESC) were analyzed by Pacific Northwest National Laboratory (PNNL) to determine headspace concentrations of selected non-radioactive analytes. Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Vapor concentrations from sorbent trap samples are based on measured sample volumes provided by SESC. Ammonia was determined to be above the immediate notification limit of 150 ppm as specified by the sampling and analysis planmore » (SAP). Hydrogen was the principal flammable constituent of the Tank S-102 headspace, determined to be present at approximately 2.410% of its lower flammability limit (LFL). Total headspace flammability was estimated to be <2.973% of its lower flammability limit (LFL). Total headspace flammability was estimated to be <2.973% of the LFL. Average measured concentrations of targeted gases, inorganic vapors, and selected organic vapors are provided in Table S.1. A summary of experimental methods, including sampling methodology, analytical procedures, and quality assurance and control methods are presented in Section 2.0. Detailed descriptions of the analytical results are provided in Section 3.0.« less

  15. Using Stable Isotopes of Carbon and Nitrogen to Evaluate Trophic Interactions in Aquatic Environments

    ERIC Educational Resources Information Center

    Christensen, David R.; LaRoche, Andrew

    2012-01-01

    This paper describes a series of laboratory exercises for upper level biology courses, independent research and/or honors programs. Students sampled fish from a local water body with the assistance of a local fish and wildlife agency. Tissue samples from collected fish were utilized to obtain estimates of the stable isotopes delta[superscript 13]C…

  16. Metagenome and metatranscriptome data for Rifle CMT-03 laboratory microcosm experiment completed in April 2014

    DOE Data Explorer

    Jewell, Talia [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Karaoz, Ulas [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Bill, Markus [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Chakraborty, Romy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Brodie, Eoin L [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Williams, Kenneth Hurst [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Beller, Harry R [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-04-01

    Sediment samples were collected during installation of monitoring borehole CMT-03. Microcosms were constructed and inoculated under anerobic conditions with these sediments and anaerobic Rifle artificial groundwater. Microcosm metagenomes and metatranscriptomes were sampled every 5 days for a period of 20 days. The dataset gives gene-level annotations, binning, metagenomic and metatranscriptomic coverages for these microcosms.

  17. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE--COMPENDIUM OF METHODS FOR ANALYSIS OF TRACE METALS AND PESTICIDES IN DIETARY SAMPLES USING TOTAL DIET STUDY PROCEDURES (FDA-COMPENDIUM)

    EPA Science Inventory

    This compendium contains seven SOPs developed by Food and Drug Administration (FDA) laboratories for methods of analyzing trace metals in dietary samples collected using Total Diet study procedures. The SOPs include the following: (1) Quality Control for Analysis of NHEXAS Food o...

  18. Interpretation of stable isotope, denitrification, and groundwater age data for samples collected from Sandia National Laboratories /New Mexico (SNL/NM) Burn Site Groundwater Area of Concern

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Madrid, V.; Singleton, M. J.; Visser, A.

    This report combines and summarizes results for two groundwater-sampling events (October 2012 and October/November 2015) from the Sandia National Laboratories/New Mexico (SNL/NM) Burn Site Groundwater (BSG) Area of Concern (AOC) located in the Lurance Canyon Arroyo southeast of Albuquerque, NM in the Manzanita Mountains. The first phase of groundwater sampling occurred in October 2012 including samples from 19 wells at three separate sites that were analyzed by the Environmental Radiochemistry Laboratory at Lawrence Livermore National Laboratory as part of a nitrate Monitored Natural Attenuation (MNA) evaluation. The three sites (BSG, Technical Area-V, and Tijeras Arroyo) are shown on the regionalmore » hydrogeologic map and described in the Sandia Annual Groundwater Monitoring Report. The first phase of groundwater sampling included six monitoring wells at the Burn Site, eight monitoring wells at Technical Area-V, and five monitoring wells at Tijeras Arroyo. Each groundwater sample was analyzed using the two specialized analytical methods, age-dating and denitrification suites. In September 2015, a second phase of groundwater sampling took place at the Burn Site including 10 wells sampled and analyzed by the same two analytical suites. Five of the six wells sampled in 2012 were resampled in 2015. This report summarizes results from two sampling events in order to evaluate evidence for in situ denitrification, the average age of the groundwater, and the extent of recent recharge of the bedrock fracture system beneath the BSG AOC.« less

  19. Reconnaissance for uranium in the coal of Sao Paulo, Santa Catarina, and Rio Grande do Sul, Brazil

    USGS Publications Warehouse

    Haynes, Donald D.; Pierson, Charles T.; White, Max G.

    1958-01-01

    Uranium-bearing coal and carbonaceous shale of the Rio Bonito formation of Pennsylvanian age have been found in the States of Sao Paulo, Santa Catarlna and Rio Grande do Sul, Brazil. The uranium oxide content of the samples collected in the State of Sao Paulo ranges from 0.001 percent to 0.082 percent. The samples collected in Santa Catarina averaged about 0.002 percent uranium oxide; those collected in Rio Grande do Sul, about 0.003 percent uranium oxide. Since the field and laboratory investigations are still in their initial stages, only raw data on the radioactivity and uranium content of Brazilian coals are given in this report.

  20. Benthic macroinvertebrate field sampling effort required to ...

    EPA Pesticide Factsheets

    This multi-year pilot study evaluated a proposed field method for its effectiveness in the collection of a benthic macroinvertebrate sample adequate for use in the condition assessment of streams and rivers in the Neuquén Province, Argentina. A total of 13 sites, distributed across three rivers, were sampled. At each site, benthic macroinvertebrates were collected at 11 transects. Each sample was processed independently in the field and laboratory. Based on a literature review and resource considerations, the collection of 300 organisms (minimum) at each site was determined to be necessary to support a robust condition assessment, and therefore, selected as the criterion for judging the adequacy of the method. This targeted number of organisms was collected at all sites, at a minimum, when collections from all 11 transects were combined. Subsequent bootstrapping analysis of data was used to estimate whether collecting at fewer transects would reach the minimum target number of organisms for all sites. In a subset of sites, the total number of organisms frequently fell below the target when fewer than 11 transects collections were combined.Site conditions where <300 organisms might be collected are discussed. These preliminary results suggest that the proposed field method results in a sample that is adequate for robust condition assessment of the rivers and streams of interest. When data become available from a broader range of sites, the adequacy of the field

  1. Herbicide sorption to fine particulate matter suspended downwind of agricultural operations: field and laboratory investigations.

    PubMed

    Clymo, Amelia S; Shin, Jin Young; Holmen, Britt A

    2005-01-15

    Tillage-induced erosion of herbicides bound to airborne soil particles has not been quantified as a mechanism for offsite herbicide transport. This study quantifies the release of two preemergent herbicides, metolachlor and pendimethalin, to the atmosphere as gas- and particle-phase species during soil incorporation operations. Fine particulate matter (PM2.5) and gas-phase samples were collected at three sampling heights during herbicide disking into the soil in Davis, CA, in May 2000 and May 2001 using filter/PUF sampling. Quartz fiber filters (QFFs) were used in May 2000, and Teflon membrane filters (TMFs) were used in May 2001. The field data were combined with laboratory filter/PUF partitioning experiments to account for adsorption to the filter surfaces and quantify the mass of PM2.5-bound herbicides in the field samples. Laboratory results indicate a significant adsorption of metolachlor, but not pendimethalin, to the quartz filter surfaces. Metolachlor partitioning to PM2.5 collected on TMF filters resulted in corrected PM2.5 field partition coefficient values, Kp,corr = Cp/Cg, of approximately 10(-3.5) m3/microg, indicating its preference for the gas phase. Pendimethalin exhibited more semivolatile behavior,with Kp,corr values that ranged from 10(-3) to 10(-1) m3/ microg and increased with sampling height and distance downwind of the operation. An increase in pendimethalin enrichment at a height of 5 m suggests winnowing of finer, more sorptive soil components with corresponding higher transport potential. Pendimethalin was enriched in the PM2.5 samples by up to a factor of 250 compared to the field soil, indicating thatfurther research on the processes controlling the generation of PM-bound herbicides during agricultural operations is warranted to enable prediction of off-site mass fluxes by this mechanism.

  2. Chemical Constituents in Groundwater from Multiple Zones in the Eastern Snake River Plain Aquifer at the Idaho National Laboratory, Idaho, 2005-08

    USGS Publications Warehouse

    Bartholomay, Roy C.; Twining, Brian V.

    2010-01-01

    From 2005 to 2008, the U.S. Geological Survey's Idaho National Laboratory (INL) Project office, in cooperation with the U.S. Department of Energy, collected water-quality samples from multiple water-bearing zones in the eastern Snake River Plain aquifer. Water samples were collected from six monitoring wells completed in about 350-700 feet of the upper part of the aquifer, and the samples were analyzed for major ions, selected trace elements, nutrients, selected radiochemical constituents, and selected stable isotopes. Each well was equipped with a multilevel monitoring system containing four to seven sampling ports that were each isolated by permanent packer systems. The sampling ports were installed in aquifer zones that were highly transmissive and that represented the water chemistry of the top four to five model layers of a steady-state and transient groundwater-flow model. The model's water chemistry and particle-tracking simulations are being used to better define movement of wastewater constituents in the aquifer. The results of the water chemistry analyses indicated that, in each of four separate wells, one zone of water differed markedly from the other zones in the well. In four wells, one zone to as many as five zones contained radiochemical constituents that originated from wastewater disposal at selected laboratory facilities. The multilevel sampling systems are defining the vertical distribution of wastewater constituents in the eastern Snake River Plain aquifer and the concentrations of wastewater constituents in deeper zones in wells Middle 2051, USGS 132, and USGS 103 support the concept of groundwater flow deepening in the southwestern part of the INL.

  3. A Portable, Field-Deployable Analyzer for Isotopic Water Measurements

    NASA Astrophysics Data System (ADS)

    Berman, E. S.; Gupta, M.; Huang, Y. W.; Lacelle, D.; McKay, C. P.; Fortson, S.

    2015-12-01

    Water stable isotopes have for many years been used to study the hydrological cycle, catchment hydrology, and polar climate among other applications. Typically, discrete water samples are collected and transported to a laboratory for isotope analysis. Due to the expense and labor associated with such sampling, isotope studies have generally been limited in scope and time-resolution. Field sampling of water isotopes has been shown in recent years to provide dense data sets with the increased time resolution illuminating substantially greater short term variability than is generally observed during discrete sampling. A truly portable instrument also opens the possibility to utilize the instrument as a tool for identifying which water samples would be particularly interesting for further laboratory investigation. To make possible such field measurements of liquid water isotopes, Los Gatos Research has developed a miniaturized, field-deployable liquid water isotope analyzer. The prototype miniature liquid water isotope analyzer (mini-LWIA) uses LGR's patented Off-Axis ICOS (Integrated Cavity Output Spectroscopy) technology in a rugged, Pelican case housing for easy transport and field operations. The analyzer simultaneously measures both δ2H and δ18O from liquid water, with both manual and automatic water introduction options. The laboratory precision for δ2H is 0.6 ‰, and for δ18O is 0.3 ‰. The mini-LWIA was deployed in the high Arctic during the summer of 2015 at Inuvik in the Canadian Northwest Territories. Samples were collected from Sachs Harbor, on the southwest coast of Banks Island, including buried basal ice from the Lurentide Ice Sheet, some ice wedges, and other types of ground ice. Methodology and water analysis results from this extreme field deployment will be presented.

  4. Variability in baseline laboratory measurements of the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil).

    PubMed

    Ladwig, R; Vigo, A; Fedeli, L M G; Chambless, L E; Bensenor, I; Schmidt, M I; Vidigal, P G; Castilhos, C D; Duncan, B B

    2016-08-01

    Multi-center epidemiological studies must ascertain that their measurements are accurate and reliable. For laboratory measurements, reliability can be assessed through investigation of reproducibility of measurements in the same individual. In this paper, we present results from the quality control analysis of the baseline laboratory measurements from the ELSA-Brasil study. The study enrolled 15,105 civil servants at 6 research centers in 3 regions of Brazil between 2008-2010, with multiple biochemical analytes being measured at a central laboratory. Quality control was ascertained through standard laboratory evaluation of intra- and inter-assay variability and test-retest analysis in a subset of randomly chosen participants. An additional sample of urine or blood was collected from these participants, and these samples were handled in the same manner as the original ones, locally and at the central laboratory. Reliability was assessed with the intraclass correlation coefficient (ICC), estimated through a random effects model. Coefficients of variation (CV) and Bland-Altman plots were additionally used to assess measurement variability. Laboratory intra and inter-assay CVs varied from 0.86% to 7.77%. From test-retest analyses, the ICCs were high for the majority of the analytes. Notably lower ICCs were observed for serum sodium (ICC=0.50; 95%CI=0.31-0.65) and serum potassium (ICC=0.73; 95%CI=0.60-0.83), due to the small biological range of these analytes. The CVs ranged from 1 to 14%. The Bland-Altman plots confirmed these results. The quality control analyses showed that the collection, processing and measurement protocols utilized in the ELSA-Brasil produced reliable biochemical measurements.

  5. Chapter A7. Biological Indicators

    USGS Publications Warehouse

    Myers, Donna N.; Wilde, Franceska D.

    2003-01-01

    The National Field Manual for the Collection of Water-Quality Data (National Field Manual) provides guidelines and standard procedures for U.S. Geological Survey (USGS) personnel who collect data used to assess the quality of the Nation's surface-water and ground-water resources. This chapter of the manual includes procedures for the (1) determination of biochemical oxygen demand using a 5-day bioassay test; (2) collection, identification, and enumeration of fecal indicator bacteria; (3) collection of samples and information on two laboratory methods for fecal indicator viruses (coliphages); and (4) collection of samples for protozoan pathogens. Each chapter of the National Field Manual is published separately and revised periodically. Newly published and revised chapters are posted on the World Wide Web on the USGS page 'National Field Manual for the Collection of Water-Quality Data.' The URL for this page is http://pubs.water.usgs.gov/twri9A/ (accessed November 25, 2003).

  6. Telomerase activity as a marker for malignancy in feline tissues.

    PubMed

    Cadile, C D; Kitchell, B E; Biller, B J; Hetler, E R; Balkin, R G

    2001-10-01

    To establish the diagnostic significance of the telomeric repeat amplification protocol (TRAP) assay in detecting feline malignancies. Solid tissue specimens collected from 33 client-owned cats undergoing diagnostic or therapeutic procedures at the University of Illinois Veterinary Medical Teaching Hospital between July 1997 and September 1999 and an additional 20 tissue samples were collected from 3 clinically normal control cats euthanatized at the conclusion of an unrelated study. The TRAP assay was used for detection of telomerase activity. Each result was compared to its respective histopathologic diagnosis. Twenty-nine of 31 malignant and 1 of 22 benign or normal tissue samples had telomerase activity, indicating 94% sensitivity and 95% specificity of the TRAP assay in our laboratory. The diagnostic significance of telomerase activity has been demonstrated in humans and recently in dogs by our laboratory. We tested feline samples to determine whether similar patterns of telomerase activity exist. On the basis of our results, the TRAP assay may be clinically useful in providing a rapid diagnosis of malignancy in cats. The telomerase enzyme may also serve as a therapeutic target in feline tumors.

  7. [The Scope, Quality and Safety Requirements of Drug Abuse Testing].

    PubMed

    Küme, Tuncay; Karakükcü, Çiğdem; Pınar, Aslı; Coşkunol, Hakan

    2017-01-01

    The aim of this review is to inform about the scopes and requirements of drug abuse testing. Drug abuse testing is one of the tools for determination of drug use. It must fulfill the quality and safety requirements in judgmental legal and administrative decisions. Drug abuse testing must fulfill some requirements like selection of the appropriate test matrix, appropriate screening test panel, sampling in detection window, patient consent, identification of the donor, appropriate collection site, sample collection with observation, identification and control of the sample, specimen custody chain in preanalytical phase; analysis in authorized laboratories, specimen validity tests, reliable testing METHODS, strict quality control, two-step analysis in analytical phase; storage of the split specimen, confirmation of the split specimen in the objection, result custody chain, appropriate cut-off concentration, the appropriate interpretation of the result in postanalytical phase. The workflow and analytical processes of drug abuse testing are explained in last regulation of the Department of Medical Laboratory Services, Ministry of Health in Turkey. The clinical physicians have to know and apply the quality and safety requirements in drug abuse testing according to last regulations in Turkey.

  8. Reference intervals for 24 laboratory parameters determined in 24-hour urine collections.

    PubMed

    Curcio, Raffaele; Stettler, Helen; Suter, Paolo M; Aksözen, Jasmin Barman; Saleh, Lanja; Spanaus, Katharina; Bochud, Murielle; Minder, Elisabeth; von Eckardstein, Arnold

    2016-01-01

    Reference intervals for many laboratory parameters determined in 24-h urine collections are either not publicly available or based on small numbers, not sex specific or not from a representative sample. Osmolality and concentrations or enzymatic activities of sodium, potassium, chloride, glucose, creatinine, citrate, cortisol, pancreatic α-amylase, total protein, albumin, transferrin, immunoglobulin G, α1-microglobulin, α2-macroglobulin, as well as porphyrins and their precursors (δ-aminolevulinic acid and porphobilinogen) were determined in 241 24-h urine samples of a population-based cohort of asymptomatic adults (121 men and 120 women). For 16 of these 24 parameters creatinine-normalized ratios were calculated based on 24-h urine creatinine. The reference intervals for these parameters were calculated according to the CLSI C28-A3 statistical guidelines. By contrast to most published reference intervals, which do not stratify for sex, reference intervals of 12 of 24 laboratory parameters in 24-h urine collections and of eight of 16 parameters as creatinine-normalized ratios differed significantly between men and women. For six parameters calculated as 24-h urine excretion and four parameters calculated as creatinine-normalized ratios no reference intervals had been published before. For some parameters we found significant and relevant deviations from previously reported reference intervals, most notably for 24-h urine cortisol in women. Ten 24-h urine parameters showed weak or moderate sex-specific correlations with age. By applying up-to-date analytical methods and clinical chemistry analyzers to 24-h urine collections from a large population-based cohort we provide as yet the most comprehensive set of sex-specific reference intervals calculated according to CLSI guidelines for parameters determined in 24-h urine collections.

  9. Yellow Fever Outbreak, Imatong, Southern Sudan

    PubMed Central

    Ofula, Victor O.; Sang, Rosemary C.; Konongoi, Samson L.; Sow, Abdourahmane; De Cock, Kevin M.; Tukei, Peter M.; Okoth, Fredrick A.; Swanepoel, Robert; Burt, Felicity J.; Waters, Norman C.; Coldren, Rodney L.

    2004-01-01

    In May 2003, the World Health Organization received reports about a possible outbreak of a hemorrhagic disease of unknown cause in the Imatong Mountains of southern Sudan. Laboratory investigations were conducted on 28 serum samples collected from patients in the Imatong region. Serum samples from 13 patients were positive for immunoglobulin M antibody to flavivirus, and serum samples from 5 patients were positive by reverse transcription–polymerase chain reaction with both the genus Flavivirus–reactive primers and yellow fever virus–specific primers. Nucleotide sequencing of the amplicons obtained with the genus Flavivirus oligonucleotide primers confirmed yellow fever virus as the etiologic agent. Isolation attempts in newborn mice and Vero cells from the samples yielded virus isolates from five patients. Rapid and accurate laboratory diagnosis enabled an interagency emergency task force to initiate a targeted vaccination campaign to control the outbreak. PMID:15207058

  10. Spectrophotometric Method for the Determination of Atmospheric Cr Pollution as a Factor to Accelerated Corrosion.

    PubMed

    Homa, Dereje; Haile, Ermias; Washe, Alemayehu P

    2017-01-01

    The effect of Cr(VI) pollution on the corrosion rate of corrugated iron roof samples collected from tanning industry areas was investigated through simulated laboratory exposure and spectrophotometric detection of Cr(III) deposit as a product of the reaction. The total level of Cr detected in the samples ranged from 113.892 ± 0.17 ppm to 53.05 ± 0.243 ppm and showed increasing trend as sampling sites get closer to the tannery and in the direction of tannery effluent stream. The laboratory exposure of a newly manufactured material to a simulated condition showed a relatively faster corrosion rate in the presence of Cr(VI) with concomitant deposition of Cr(III) under pH control. A significant ( P = 0.05) increase in the corrosion rate was also recorded when exposing scratched or stress cracked samples. A coupled redox process where Cr(VI) is reduced to a stable, immobile, and insoluble Cr(III) accompanying corrosion of the iron is proposed as a possible mechanism leading to the elevated deposition of the latter on the materials. In conclusion, the increased deposits of Cr detected in the corrugated iron roof samples collected from tanning industry zones suggested possible atmospheric Cr pollution as a factor to the accelerated corrosion of the materials.

  11. Collaborative Health and Enforcement Operations on the Quality of Antimalarials and Antibiotics in Southeast Asia

    PubMed Central

    Yong, Yuk Lin; Plançon, Aline; Lau, Yen Hui; Hostetler, Dana M.; Fernández, Facundo M.; Green, Michael D.; Sounvoravong, Sourisak; Nara, Suon; Boravann, Mam; Dumrong, Thitikornkovit; Bangsawan, Nurjaya; Low, Min Yong; Lim, Chin-Chin; Ai, Ruth Lee Choo; Newton, Paul N.

    2015-01-01

    Counterfeit (or falsified) and substandard medicines pose a major public health risk. We describe the findings of Operation Storm I and II conducted in 2008–2009 to combat counterfeit medicines through partnership between national customs, Drug Regulatory Agencies (DRAs), and police in Cambodia, Indonesia, Laos, Myanmar, Singapore, Thailand, and Vietnam. Samples were obtained from seizures and market surveillance by national DRAs. Laboratory analysis using spectroscopic and chromatographic techniques and examination of packaging were performed. Ninety-three suspect antibiotics and 95 antimalarial samples were collected. Of the 93 antibiotics, 29 (31%) had % active pharmaceutical ingredient content (%API) < 85% or > 115% (including one counterfeit). Of the 95 antimalarials, 30 (32%) had %API < 85 > 115% API (including one counterfeit). A significant minority of samples, antimalarials (13%) and antibiotics (15%), were collected in plastic bags with minimal or no labeling. Of 20 ampicillin samples, 13 (65%) contained < 85% API (with one counterfeit containing additional amoxicillin). Of 34 oral artesunate samples, 7 (21%) contained %API out of the 85–115% range. Coordinated and synergistic partnership adopted by the participating countries, International Criminal Police Organization (INTERPOL), World Health Organization (WHO), and laboratories facilitated a platform for discussions and intelligence sharing, helping to improve each participating country's capacity to combat poor-quality medicines. PMID:25897069

  12. Spectrophotometric Method for the Determination of Atmospheric Cr Pollution as a Factor to Accelerated Corrosion

    PubMed Central

    Homa, Dereje; Haile, Ermias

    2017-01-01

    The effect of Cr(VI) pollution on the corrosion rate of corrugated iron roof samples collected from tanning industry areas was investigated through simulated laboratory exposure and spectrophotometric detection of Cr(III) deposit as a product of the reaction. The total level of Cr detected in the samples ranged from 113.892 ± 0.17 ppm to 53.05 ± 0.243 ppm and showed increasing trend as sampling sites get closer to the tannery and in the direction of tannery effluent stream. The laboratory exposure of a newly manufactured material to a simulated condition showed a relatively faster corrosion rate in the presence of Cr(VI) with concomitant deposition of Cr(III) under pH control. A significant (P = 0.05) increase in the corrosion rate was also recorded when exposing scratched or stress cracked samples. A coupled redox process where Cr(VI) is reduced to a stable, immobile, and insoluble Cr(III) accompanying corrosion of the iron is proposed as a possible mechanism leading to the elevated deposition of the latter on the materials. In conclusion, the increased deposits of Cr detected in the corrugated iron roof samples collected from tanning industry zones suggested possible atmospheric Cr pollution as a factor to the accelerated corrosion of the materials. PMID:28469950

  13. Sampling for mercury at subnanogram per litre concentrations for load estimation in rivers

    USGS Publications Warehouse

    Colman, J.A.; Breault, R.F.

    2000-01-01

    Estimation of constituent loads in streams requires collection of stream samples that are representative of constituent concentrations, that is, composites of isokinetic multiple verticals collected along a stream transect. An all-Teflon isokinetic sampler (DH-81) cleaned in 75??C, 4 N HCl was tested using blank, split, and replicate samples to assess systematic and random sample contamination by mercury species. Mean mercury concentrations in field-equipment blanks were low: 0.135 ng??L-1 for total mercury (??Hg) and 0.0086 ng??L-1 for monomethyl mercury (MeHg). Mean square errors (MSE) for ??Hg and MeHg duplicate samples collected at eight sampling stations were not statistically different from MSE of samples split in the laboratory, which represent the analytical and splitting error. Low fieldblank concentrations and statistically equal duplicate- and split-sample MSE values indicate that no measurable contamination was occurring during sampling. Standard deviations associated with example mercury load estimations were four to five times larger, on a relative basis, than standard deviations calculated from duplicate samples, indicating that error of the load determination was primarily a function of the loading model used, not of sampling or analytical methods.

  14. 40 CFR 763.87 - Analysis.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT ASBESTOS Asbestos-Containing Materials in Schools § 763.87 Analysis. (a) Local education agencies shall have bulk samples, collected under § 763.86 and submitted for analysis, analyzed for asbestos using laboratories...

  15. 40 CFR 763.87 - Analysis.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT ASBESTOS Asbestos-Containing Materials in Schools § 763.87 Analysis. (a) Local education agencies shall have bulk samples, collected under § 763.86 and submitted for analysis, analyzed for asbestos using laboratories...

  16. 40 CFR 763.87 - Analysis.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT ASBESTOS Asbestos-Containing Materials in Schools § 763.87 Analysis. (a) Local education agencies shall have bulk samples, collected under § 763.86 and submitted for analysis, analyzed for asbestos using laboratories...

  17. 40 CFR 763.87 - Analysis.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT ASBESTOS Asbestos-Containing Materials in Schools § 763.87 Analysis. (a) Local education agencies shall have bulk samples, collected under § 763.86 and submitted for analysis, analyzed for asbestos using laboratories...

  18. 40 CFR 763.87 - Analysis.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT ASBESTOS Asbestos-Containing Materials in Schools § 763.87 Analysis. (a) Local education agencies shall have bulk samples, collected under § 763.86 and submitted for analysis, analyzed for asbestos using laboratories...

  19. Concentrations of selected pharmaceuticals and antibiotics in south-central Pennsylvania waters, March through September 2006

    USGS Publications Warehouse

    Loper, Connie A.; Crawford, J. Kent; Otto, Kim L.; Manning, Rhonda L.; Meyer, Michael T.; Furlong, Edward T.

    2007-01-01

    This report presents environmental and quality-control data from analyses of 15 pharmaceutical and 31 antibiotic compounds in water samples from streams and wells in south-central Pennsylvania. The analyses are part of a study by the U.S. Geological Survey (USGS) in cooperation with the Pennsylvania Department of Environmental Protection (PADEP) to define concentrations of selected emerging contaminants in streams and well water in Pennsylvania. Sampling was conducted at 11 stream sites and at 6 wells in 9 counties of south-central Pennsylvania. Five of the streams received municipal wastewater and 6 of the streams received runoff from agricultural areas dominated by animal-feeding operations. For all 11 streams, samples were collected at locations upstream and downstream of the municipal effluents or animal-feeding operations. All six wells were in agricultural settings. A total of 120 environmental samples and 21 quality-control samples were analyzed for the study. Samples were collected at each site in March/April, May, July, and September 2006 to obtain information on changes in concentration that could be related to seasonal use of compounds.For streams, 13 pharmaceuticals and 11 antibiotics were detected at least 1 time. Detections included analytical results that were estimated or above the minimum reporting limits. Seventy-eight percent of all detections were analyzed in samples collected downstream from municipal-wastewater effluents. For streams receiving wastewater effluents, the pharmaceuticals caffeine and para-xanthine (a degradation product of caffeine) had the greatest concentrations, 4.75 μg/L (micrograms per liter) and 0.853 μg/L, respectively. Other pharmaceuticals and their respective maximum concentrations were carbamazepine (0.516 μg/L) and ibuprofen (0.277 μg/L). For streams receiving wastewater effluents, the antibiotic azithromycin had the greatest concentration (1.65 μg/L), followed by sulfamethoxazole (1.34 μg/L), ofloxacin (0.329 μg/L), and trimethoprim (0.256 μg/L).For streams receiving runoff from animal-feeding operations, the only pharmaceuticals detected were acetaminophen, caffeine, cotinine, diphenhydramine, and carbamazepine. The maximum concentration for pharmaceuticals was 0.053 μg/L. Three streams receiving runoff from animal-feeding operations had detections of one or more antibiotic compound--oxytetracycline, sulfadimethoxine, sulfamethoxazole, and tylosin. The maximum concentration for antibiotics was 0.157 μg/L. The average number of compounds (pharmaceuticals and antibiotics) detected in sites downstream from animal-feeding operations was three. The average number of compounds detected downstream from municipal-wastewater effluents was 13.For wells used to supply livestock, four compounds were detected--two pharmaceuticals (cotinine and diphenhydramine) and two antibiotics (tylosin and sulfamethoxazole). There were five detections in all the well samples. The maximum concentration detected in well water was for cotinine, estimated to be 0.024 μg/L.Seasonal occurrence of pharmaceutical and antibiotic compounds in stream water varied by compound and site type. At four stream sites, the same compounds were detected in all four seasonal samples. At other sites, pharmaceutical or antibiotic compounds were detected only one time in seasonal samples. Winter samples collected in streams receiving municipalwastewater effluent had the greatest number of compounds detected (21). Research analytical methods were used to determine concentrations for pharmaceuticals and antibiotics. To assist in evaluating the quality of the analyses, detailed information is presented on laboratory methodology and results from qualitycontrol samples. Quality-control data include results for nine blanks, nine duplicate environmental sample pairs, and three laboratory-spiked environmental samples as well as the recoveries of compounds in laboratory surrogates and laboratory reagent spikes.

  20. PubMed Central

    Miezan, T.; Doua, F.; Cattand, P.; de Raadt, P.

    1991-01-01

    The Testryp CATT was performed on dried blood samples on filter-paper and on diluted blood using a microtechnique. This method was applied to both sample collection techniques and was evaluated in parallel with the classical Testryp CATT on whole blood, as described in the instructions provided with the reagents by the manufacturer. A total of 2087 people were tested; 453 samples were tested in the laboratory and 1634 during a field survey in 5 villages of a trypanosomiasis focus in Daloa, Côte d'Ivoire. This study has demonstrated that the Testryp CATT micromethod on either type of sample collection gives results comparable to the Testryp CATT on whole blood. The collection of dried blood samples on filter-paper can be performed by non-specialized staff in trypanosomiasis control programmes of the national health services. In addition, a flask of CATT reagent will allow testing of 6 times more people by the micromethod than by the classical whole-blood method. The micromethod is suitable in the implementation of programmes for the serological surveillance of populations at risk. PMID:1959162

  1. Nest Mosquito Trap quantifies contact rates between nesting birds and mosquitoes.

    PubMed

    Caillouët, Kevin A; Riggan, Anna E; Rider, Mark; Bulluck, Lesley P

    2012-06-01

    Accurate estimates of host-vector contact rates are required for precise determination of arbovirus transmission intensity. We designed and tested a novel mosquito collection device, the Nest Mosquito Trap (NMT), to collect mosquitoes as they attempt to feed on unrestrained nesting birds in artificial nest boxes. In the laboratory, the NMT collected nearly one-third of the mosquitoes introduced to the nest boxes. We then used these laboratory data to estimate our capture efficiency of field-collected bird-seeking mosquitoes collected over 66 trap nights. We estimated that 7.5 mosquitoes per trap night attempted to feed on nesting birds in artificial nest boxes. Presence of the NMT did not have a negative effect on avian nest success when compared to occupied nest boxes that were not sampled with the trap. Future studies using the NMT may elucidate the role of nestlings in arbovirus transmission and further refine estimates of nesting bird and vector contact rates. © 2012 The Society for Vector Ecology.

  2. Nest Mosquito Trap quantifies contact rates between nesting birds and mosquitoes

    PubMed Central

    Caillouët, Kevin A.; Riggan, Anna E.; Rider, Mark; Bulluck, Lesley P.

    2012-01-01

    Accurate estimates of host-vector contact rates are required for precise determination of arbovirus transmission intensity. We designed and tested a novel mosquito collection device, the Nest Mosquito Trap (NMT), to collect mosquitoes as they attempt to feed on unrestrained nesting birds in artificial nest boxes. In the laboratory, the NMT collected nearly one-third of the mosquitoes introduced to the nest boxes. We then used these laboratory data to estimate our capture efficiency of field-collected bird-seeking mosquitoes collected over 66 trap nights. We estimated that 7.5 mosquitoes per trap night attempted to feed on nesting birds in artificial nest boxes. Presence of the NMT did not have a negative effect on avian nest success when compared to occupied nest boxes that were not sampled with the trap. Future studies using the NMT may elucidate the role of nestlings in arbovirus transmission and further refine estimates of nesting bird and vector contact rates. PMID:22548555

  3. Understanding Microplastic Distribution: A Global Citizen Monitoring Effort

    NASA Astrophysics Data System (ADS)

    Barrows, A.

    2016-02-01

    Understanding distribution and abundance of microplastics in the world's oceans will continue to help inform global law-making. Through recruiting and training over 500 volunteers our study has collected over 1000 samples from remote and populated areas world-wide. Samples include water collected at the sea surface and throughout the water column. Surface to depth sampling has provided insight into vertical plastic distribution. The development of unique field and laboratory methodology has enabled plastics to be quantified down to 50 µm. In 2015, the study expanded to include global freshwater systems. By understanding plastic patterns, distribution and concentration in large and small watersheds we will better understand how freshwater systems are contributing to marine microplastic pollution.

  4. Restoration and PDS Archive of Apollo Lunar Rock Sample Data

    NASA Technical Reports Server (NTRS)

    Garcia, P. A.; Todd, N. S.; Lofgren, G. E.; Stefanov, W. L.; Runco, S. K.; LaBasse, D.; Gaddis, L. R.

    2011-01-01

    In 2008, scientists at the Johnson Space Center (JSC) Lunar Sample Laboratory and Image Science & Analysis Laboratory (under the auspices of the Astromaterials Research and Exploration Science Directorate or ARES) began work on a 4-year project to digitize the original film negatives of Apollo Lunar Rock Sample photographs. These rock samples together with lunar regolith and core samples were collected as part of the lander missions for Apollos 11, 12, 14, 15, 16 and 17. The original film negatives are stored at JSC under cryogenic conditions. This effort is data restoration in the truest sense. The images represent the only record available to scientists which allows them to view the rock samples when making a sample request. As the negatives are being scanned, they are also being formatted and documented for permanent archive in the NASA Planetary Data System (PDS) archive. The ARES group is working collaboratively with the Imaging Node of the PDS on the archiving.

  5. Laboratory Studies of Cometary Materials - Continuity Between Asteroid and Comet

    NASA Technical Reports Server (NTRS)

    Messenger, Scott; Walker, Robert M.

    2015-01-01

    Laboratory analysis of cometary samples have been enabled by collection of cometary dust in the stratosphere by high altitude aircraft and by the direct sampling of the comet Wild-2 coma by the NASA Stardust spacecraft. Cometary materials are composed of a complex assemblage of highly primitive, unprocessed interstellar and primordial solar system materials as well as a variety of high temperature phases that must have condensed in the inner regions of the protoplanetary disk. These findings support and contradict conclusions of comet properties based solely on astronomical observations. These sample return missions have instead shown that there is a continuity of properties between comets and asteroids, where both types of materials show evidence for primitive and processed materials. Furthermore, these findings underscore the importance and value of direct sample return. There will be great value in comparing the findings of the Stardust cometary coma sample return mission with those of future asteroid surface sample returns OSIRIS-REx and Hayabusa II as well as future comet nucleus sample returns.

  6. May 2011 Groundwater and Surface Water Sampling at the Rio Blanco, Colorado, Site (Data Validation Package)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hutton, Rick

    2011-12-01

    Annual sampling was conducted at the Rio Blanco, Colorado, site for the Long-Term Hydrologic Monitoring Program May 16-17, 2011, to monitor groundwater and surface water for potential radionuclide contamination. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for the U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). A duplicate sample was collected from location Johnson Artesian WL. Samples were analyzed by the U.S. Environmental Protection Agency (EPA) Radiation&Indoor Environments National Laboratory in Las Vegas, Nevada. Samples were analyzed for gamma-emitting radionuclides by high-resolution gamma spectrometry, and for tritium using the conventional method.more » Tritium was not measured using the enrichment method because the EPA laboratory no longer offers that service. Results of this monitoring at the Rio Blanco site demonstrate that groundwater and surface water outside the boundaries have not been affected by project-related contaminants.« less

  7. The Fulton County Medical Examiner's experience with the Federal Bureau of Investigation National Missing Person DNA Database Program, 2004-2007.

    PubMed

    Heninger, Michael; Hanzlick, Randy

    2011-03-01

    Medical examiners and coroners occasionally encounter unidentified human bodies, which remain unidentified for extended periods. In such cases, when traditional methods of identification have failed or cannot be used, DNA profiling may be used. The Federal Bureau of Investigation has a National Missing Person DNA database (NMPDD) laboratory to which samples may be submitted on such cases and from possible relatives or environments of unidentified decedents. This article describes the experience of the Fulton County Medical Examiner (FCME) in submitting samples to the NMPDD laboratory. A database was established at the FCME to track the submission of samples from unidentified decedents to the NMPDD laboratory for DNA testing along with the results and turnaround times. In December 2004, the FCME inventoried all cases for which samples were available and began to submit them to the NMPDD laboratory for testing. DNA testing and isolation rates, sample type, and turnaround times were tabulated in October 2006 for samples submitted between December 16, 2004 and December 16, 2005. An overall summary of data was also prepared concerning the status of all samples submitted as of April 17, 2007. During the 1-year study period, samples from 77 unidentified decedents were submitted to the laboratory. As of October 2006 (22 months after submission of the first samples and 10 months after submission of the last samples), testing had been completed on 53% of the samples submitted, and 68% of those tested resulted in a mitochondrial DNA profile. Turnaround times ranged from 66 to 557 days, improved with time, and had a mean of 107 days for specimens submitted during the latter part of the study period. As of April 17, 2007, we had submitted samples involving 84 unidentified decedents. Seventy-five percent of the samples have now been tested. Data from the NMPDD laboratory have resulted in 4 identifications by comparison with putative relatives, 4 exclusions, and no cold hits through comparison NMPDD DNA profiles from missing persons. More extensive data are presented in the body of this article. The NMPDD laboratory provides useful and free services to medical examiners, coroners, and law enforcement agencies that require DNA services regarding missing and unidentified persons. Turnaround times have improved. The success of the system in getting cold hits will be heavily dependent on law enforcement filing missing persons reports and submission of reference samples from putative relatives of the decedent. We recommend collecting specimens for DNA analysis early on in the postmortem investigation, submitting samples to the NMPDD laboratory or one of its participating laboratories when traditional methods for identification cannot be used or have failed, not burying bodies until a DNA profile has been obtained, and not cremating unidentified remains.

  8. Water-chemistry and on-site sulfur-speciation data for selected springs in Yellowstone National Park, Wyoming, 1994-1995

    USGS Publications Warehouse

    Ball, James W.; Nordstrom, D. Kirk; Cunningham, Kirk M.; Schoonen, Martin A.; Xu, Yong; DeMonge, Jennifer M.

    1998-01-01

    Forty-two water analyses are reported for samples collected at 8 hot springs and their overflow drainages, two geysers, and two ambient-temperature acid streams in Yellowstone National Park during 1994-95. These water samples were collected and analyzed as part of the initial research investigations on sulfur redox speciation in the hot springs of Yellowstone and to document chemical changes in overflows that affect major ions, redox species, and trace elements. The sulfur redox speciation research is a collaboration between the State University of New York (SUNY) at Stony Brook and the U.S. Geological Survey (USGS). Four hot springs, Ojo Caliente, Azure, Frying Pan, and Angel Terrace, were studied in detail. Analyses were performed adjacent to the sampling site or in an on-site mobile lab truck constructed by the USGS, or later in a USGS laboratory. Water temperature, specific conductance, pH, Eh, D.O., and dissolved H2S were determined adjacent to the sample source at the time of sampling. Alkalinity and F- were determined on-site on the day of sample collection. Thiosulfate and polythionates were determined as soon as possible (minutes to hours later) by ion chromatography (IC). Other major anions (Cl-, SO4 2-, Br-) also were determined on-site by IC within two days of sample collection. Ammonium, Fe(II), and Fe(total) were determined on-site by ultraviolet/visible spectrophotometry within two days of sample collection. Later in the USGS laboratory, densities were determined. Concentrations of Ca, Mg, Li, Na, and K were determined by flame atomic absorption and emission (Na, K) spectrometry. Concentrations of Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe(total), K, Mg, Mn, Na, Ni, Pb, Si, Sr, V, and Zn were determined by inductively-coupled plasma optical emission spectrometry. Trace concentrations of Al and Mg were determined by Zeeman-corrected graphite furnace atomic absorption spectrometry. Three important conclusions from the sampling and analyses are: (1) variability in H2S concentrations can be caused as much by sampling and preservation artifacts as by actual variations in water composition over time, (2) historical determinations of S2O3 2- were subject to overestimation, most likely because of inadequate preservation leading to H2S oxidation, and (3) S2O3 2- is a common constituent of hot spring waters.

  9. Effects of three phosphate industrial sites on ground-water quality in central Florida, 1979 to 1980

    USGS Publications Warehouse

    Miller, R.L.; Sutcliffe, Horace

    1984-01-01

    Geologic, hydrologic, and water quality data and information on test holes collected in the vicinity of gypsum stack complexes at two phosphate chemical plants and one phosphatic clayey waste disposal pond at a phosphate mine and beneficiation plant in central Florida are presented. The data were collected from September 1979 to October 1980 at the AMAX Phosphate, Inc. chemical plant, Piney Point; the USS Agri-Chemicals chemical plant, Bartow; and the International Minerals and Chemical Corporation Clear Springs mine, Bartow. Approximately 5,400 field and laboratory water quality determinations on water samples collected from about 100 test holes and 28 surface-water , 5 rainfall, and other sampling sites at phosphate industry beneficiation and chemical plant waste disposal operations are tabulated. Maps are included to show sampling sites. (USGS)

  10. Water-quality and hydrogeologic data for three phosphate industry waste-disposal sites in central Florida, 1979-80

    USGS Publications Warehouse

    Miller, Ronald L.; Sutcliffe, Horace

    1982-01-01

    This report is a complilation of geologic, hydrologic, and water-quality data and information on test holes collected in the vicinity of gypsum stack complexes at two phosphate chemical plants and one phosphatic clayey waste disposal pond at a phosphate mine and beneficiation plant in central Florida. The data were collected from September 1979 to October 1980 at thee AMAX Phosphate, Inc., chemical plant, Piney Point; the USS AgriChemicals chemical plant, Bartow; and the International Minerals and Chemical Corporation Clear Springs mine, Bartow. Approximmmtely 5,400 field and laboratory water-quality determinations on water samples were collected from about 78 test holes and 31 surface-water, rainfall, and other sampling sites at phosphate industry beneficiation and chemical plant waste-disposal operations. Maps show locations of sampling sites. (USGS)

  11. Collection of Aerosolized Human Cytokines Using Teflon® Filters

    PubMed Central

    McKenzie, Jennifer H.; McDevitt, James J.; Fabian, M. Patricia; Hwang, Grace M.; Milton, Donald K.

    2012-01-01

    Background Collection of exhaled breath samples for the analysis of inflammatory biomarkers is an important area of research aimed at improving our ability to diagnose, treat and understand the mechanisms of chronic pulmonary disease. Current collection methods based on condensation of water vapor from exhaled breath yield biomarker levels at or near the detection limits of immunoassays contributing to problems with reproducibility and validity of biomarker measurements. In this study, we compare the collection efficiency of two aerosol-to-liquid sampling devices to a filter-based collection method for recovery of dilute laboratory generated aerosols of human cytokines so as to identify potential alternatives to exhaled breath condensate collection. Methodology/Principal Findings Two aerosol-to-liquid sampling devices, the SKC® Biosampler and Omni 3000™, as well as Teflon® filters were used to collect aerosols of human cytokines generated using a HEART nebulizer and single-pass aerosol chamber setup in order to compare the collection efficiencies of these sampling methods. Additionally, methods for the use of Teflon® filters to collect and measure cytokines recovered from aerosols were developed and evaluated through use of a high-sensitivity multiplex immunoassay. Our results show successful collection of cytokines from pg/m3 aerosol concentrations using Teflon® filters and measurement of cytokine levels in the sub-picogram/mL concentration range using a multiplex immunoassay with sampling times less than 30 minutes. Significant degradation of cytokines was observed due to storage of cytokines in concentrated filter extract solutions as compared to storage of dry filters. Conclusions Use of filter collection methods resulted in significantly higher efficiency of collection than the two aerosol-to-liquid samplers evaluated in our study. The results of this study provide the foundation for a potential new technique to evaluate biomarkers of inflammation in exhaled breath samples. PMID:22574123

  12. Total Mercury in Surface and Deep Waters in the Western and Eastern Mediterranean Sea

    NASA Astrophysics Data System (ADS)

    Varde', M.; Cofone, F.; Servidio, A.; Rosselli, A.; Hedgecock, I. M.; Ammoscato, I.; Mannarino, V.; Sprovieri, F.; Gensini, M.; Pirrone, N.

    2014-12-01

    In the framework of the Italian National Research Council (CNR) Med-Oceanor measurement program and as part of the Global Mercury Observation System (GMOS) objectives, we performed two cruise campaigns with the CNR's Research Vessel (RV) Urania, in the western and eastern Mediterranean Basin, in the summers of 2012 and 2013. Total Mercury (THg) concentration in seawater was systematically measured at different depths from the sea bottom to the surface. A total of 155 surface and deep seawater samples at 25 selected stations were collected during the cruise campaigns using a stainless-steel rosette system on which 24 Niskin bottles (10L) were mounted. Continuous monitoring of temperature, conductivity, salinity and oxygen with depth were obtained by CTD measurements. All fluorinated containers were cleaned prior to use following GMOS SOPs. The chemical reagents used were suitable for ultra-trace Hg analysis. After sampling, samples were preserved by adding HCl solution to the sample bottles, which were refrigerated during transportation and analyzed within four weeks of the end of the oceanographic campaign. Sea water samples were analyzed in the laboratory following the US-EPA 1631 method revision E (US-EPA, 2002). To assess the critical issues related to mercury (Hg) contamination and to prevent leakage of Hg through volatilization we used all necessary precautions for sampling, sample stabilization, preservation and subsequent analysis in the laboratory. Quality assurance and quality control were performed using transport blanks, laboratory blanks and use of seawater certified reference materials. The accuracy of the analytical procedures for the determination of THg in sea water was corroborated by participation in a global inter-laboratory comparison study for THg in natural waters. THg concentrations in surface and deep waters found in the Mediterranean basin during the last two cruise campaigns Med-Oceanor as well as the THg measurements in sea water collected in the other programs and oceanographic campaigns will help to further our understanding of Hg marine distribution and its impact on the biogeochemical cycle of Hg in the open ocean.

  13. Assessment of nonpoint source chemical loading potential to watersheds containing uranium waste dumps associated with uranium exploration and mining, San Rafael Swell, Utah

    USGS Publications Warehouse

    Freeman, Michael L.; Naftz, David L.; Snyder, Terry; Johnson, Greg

    2008-01-01

    During July and August of 2006, 117 solid-phase samples were collected from abandoned uranium waste dumps, geologic background sites, and adjacent streambeds in the San Rafael Swell, in southeastern Utah. The objective of this sampling program was to assess the nonpoint source chemical loading potential to ephemeral and perennial watersheds from uranium waste dumps on Bureau of Land Management property. Uranium waste dump samples were collected using solid-phase sampling protocols. After collection, solid-phase samples were homogenized and extracted in the laboratory using a field leaching procedure. Filtered (0.45 micron) water samples were obtained from the field leaching procedure and were analyzed for Ag, As, Ba, Be, Cd, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, U, V, and Zn at the Inductively Coupled Plasma-Mass Spectrometry Metals Analysis Laboratory at the University of Utah, Salt Lake City, Utah and for Hg at the U.S. Geological Survey National Water Quality Laboratory, Denver, Colorado. For the initial ranking of chemical loading potential of suspect uranium waste dumps, leachate analyses were compared with existing aquatic life and drinking-water-quality standards and the ratio of samples that exceeded standards to the total number of samples was determined for each element having a water-quality standard for aquatic life and drinking-water. Approximately 56 percent (48/85) of the leachate samples extracted from uranium waste dumps had one or more chemical constituents that exceeded aquatic life and drinking-water-quality standards. Most of the uranium waste dump sites with elevated trace-element concentrations in leachates were along Reds Canyon Road between Tomsich Butte and Family Butte. Twelve of the uranium waste dump sites with elevated trace-element concentrations in leachates contained three or more constituents that exceeded drinking-water-quality standards. Eighteen of the uranium waste dump sites had three or more constituents that exceeded trace-element concentrations for aquatic life water-quality standards. The proximity of the uranium waste dumps in the Tomsich Butte area near Muddy Creek, coupled with the elevated concentration of trace elements, increases the offsite impact potential to water resources. Future assessment and remediation priority of these areas may be done by using GIS-based risk-mapping techniques, such as Sensitive Catchment Integrated Mapping and Analysis Project.

  14. Validation of two commercial real-time RT-PCR kits for rapid and specific diagnosis of classical swine fever virus.

    PubMed

    Le Dimna, M; Vrancken, R; Koenen, F; Bougeard, S; Mesplède, A; Hutet, E; Kuntz-Simon, G; Le Potier, M F

    2008-01-01

    Two real-time RT-PCR kits, developed by LSI (TaqVet CSF) and ADIAGENE (Adiavet CSF), obtained an agreement to be commercialised in France, subject to conditions, defined by the French Classical Swine Fever (CSF) National Reference Laboratory. The producers were asked to introduce an internal control to check the RNA extraction efficacy. The different criteria assessed were sensitivity, "pestivirus specificity", reproducibility and ease of handling, using 189 different samples. These samples were either CSFV inactivated strains or blood/serum/organs collected from CSFV experimentally infected pigs or naturally infected wild boars. The reproducibility of the assays was confirmed by the analysis of a batch-to-batch panel control that was used for inter-laboratory tests involving nine laboratories. The two kits were also tested for the use in mass diagnostics and the results proved the kits to be suited using pools of blood, serum and tonsils. Moreover, a field evaluation, carried out on spleen samples collected from the CSF surveillance of wild boars in an area known to be infected and from domestic pigs at a slaughterhouse, confirmed the high sensitivity and specificity of the two kits. This step-by-step evaluation procedure confirmed that the two commercial CSF real-time RT-PCR kits have a higher predictive value than the current diagnostic standard, Virus Isolation.

  15. Feasibility of a Fieldable Mass Spectrometer FY 2015 Year-end Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barinaga, Charles J.; Hager, George J.; Hoegg, Edward D.

    Currently, the International Atomic Energy Agency (IAEA) monitors the production of enriched uranium hexafluoride (UF 6) at declared facilities by collecting a few grams of product in sample tubes that are then sent to central laboratories for processing and isotope ratio analysis by thermal ionization mass spectrometry. Analysis of results may not be available for some time after collection. In addition, new shipping regulations will make it more difficult to transport this amount of UF 6 to a laboratory. The IAEA is interested in an isotope ratio technique for uranium in UF 6 that can be moved to and operatedmore » at the enrichment facility itself. This report covers the tasks and activities of the Feasibility of a Fieldable Mass Spectrometer Project for FY 2015, which investigates the feasibility of an in-field isotope ratio technique— the forward deployment of a technique to the non-laboratory situation of a protected room with power and heat at the facility of interest. A variety of nontraditional elemental ionization techniques were considered. It was determined that only two of these should be moved forward for testing with the candidate in-field mass spectrometer and with the adsorbed UF 6 sample types.« less

  16. Application of solid-phase microextraction for in vivo laboratory and field sampling of pharmaceuticals in fish.

    PubMed

    Zhou, Simon Ningsun; Oakes, Ken D; Servos, Mark R; Pawliszyn, Janusz

    2008-08-15

    Previous field studies utilizing solid-phase microextraction (SPME) predominantly focused on volatile and semivolatile compounds in air or water. Earlier in vivo sampling studies utilizing SPME were limited to the liquid matrix (blood). The present study has expanded the SPME technique to semisolid tissues under laboratory and field conditions through the investigation of both theoretical and applied experimental approaches. Pre-equilibrium extraction and desorption were performed in vivo in two separate animals. Excellent linearity was found between the amounts extracted by SPME from the muscle of living fish and the waterborne concentrations of pharmaceuticals. A simple SPME method is also described to simultaneously determine free and total analyte concentrations in living tissue. The utility of in vivo SPME sampling was evaluated in wild fish collected from a number of different river locations under varying degrees of influence from municipal wastewater effluents. Diphenhydramine and diltiazem were detected in the muscle of fish downstream of a local wastewater treatment plant. Based on this study, SPME demonstrated several important advantages such as simplicity, sensitivity, and robustness under laboratory and in vivo field sampling conditions.

  17. Cosmic veto gamma-spectrometry for Comprehensive Nuclear-Test-Ban Treaty samples

    NASA Astrophysics Data System (ADS)

    Burnett, J. L.; Davies, A. V.

    2014-05-01

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT) is supported by a global network of monitoring stations that perform high-resolution gamma-spectrometry on air filter samples for the identification of 85 radionuclides. At the UK CTBT Radionuclide Laboratory (GBL15), a novel cosmic veto gamma-spectrometer has been developed to improve the sensitivity of station measurements, providing a mean background reduction of 80.8% with mean MDA improvements of 45.6%. The CTBT laboratory requirement for a 140Ba MDA is achievable after 1.5 days counting compared to 5-7 days using conventional systems. The system consists of plastic scintillation plates that detect coincident cosmic-ray interactions within an HPGe gamma-spectrometer using the Canberra LynxTM multi-channel analyser. The detector is remotely configurable using a TCP/IP interface and requires no dedicated coincidence electronics. It would be especially useful in preventing false-positives at remote station locations (e.g. Halley, Antarctica) where sample transfer to certified laboratories is logistically difficult. The improved sensitivity has been demonstrated for a CTBT air filter sample collected after the Fukushima incident.

  18. Concentrations of tritium and strontium-90 in water from selected wells at the Idaho National Engineering Laboratory after purging one, two, and three borehole volumes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartholomay, R.C.

    1993-12-31

    Water from 11 wells completed in the Snake River Plain aquifer at the Idaho National Engineering Laboratory was sampled as Part of the US. Geological Survey`s quality assurance program to determine the effect of Purging different borehole volumes on tritium and strontium-90 concentrations. Wells were selected for sampling on the basis of the length of time it took to purge a borehole volume of water. Samples were collected after purging one, two, and three borehole volumes. The US Department of Energy`s Radiological and Environmental Sciences Laboratory provided analytical services. Statistics were used to determine the reproducibility of analytical results. Themore » comparison between tritium and strontium-90 concentrations after purging one and three borehole volumes and two and three borehole volumes showed that all but two sample pairs with defined numbers were in statistical agreement. Results indicate that concentrations of tritium and strontium-90 are not affected measurably by the number of borehole volumes purged.« less

  19. Validation of a PCR-based method for the detection of various rendered materials in feedstuffs using a forensic DNA extraction kit.

    PubMed

    Myers, Michael J; Yancy, Haile F; Araneta, Michael; Armour, Jennifer; Derr, Janice; Hoostelaere, Lawrence A D; Farmer, Doris; Jackson, Falana; Kiessling, William M; Koch, Henry; Lin, Huahua; Liu, Yan; Mowlds, Gabrielle; Pinero, David; Riter, Ken L; Sedwick, John; Shen, Yuelian; Wetherington, June; Younkins, Ronsha

    2006-01-01

    A method trial was initiated to validate the use of a commercial DNA forensic kit to extract DNA from animal feed as part of a PCR-based method. Four different PCR primer pairs (one bovine pair, one porcine pair, one ovine primer pair, and one multispecies pair) were also evaluated. Each laboratory was required to analyze a total of 120 dairy feed samples either not fortified (control, true negative) or fortified with bovine meat and bone meal, porcine meat and bone meal (PMBM), or lamb meal. Feeds were fortified with the animal meals at a concentration of 0.1% (wt/wt). Ten laboratories participated in this trial, and each laboratory was required to evaluate two different primer pairs, i.e., each PCR primer pair was evaluated by five different laboratories. The method was considered to be validated for a given animal source when three or more laboratories achieved at least 97% accuracy (29 correct of 30 samples for 96.7% accuracy, rounded up to 97%) in detecting the fortified samples for that source. Using this criterion, the method was validated for the bovine primer because three laboratories met the criterion, with an average accuracy of 98.9%. The average false-positive rate was 3.0% in these laboratories. A fourth laboratory was 80% accurate in identifying the samples fortified with bovine meat and bone meal. A fifth laboratory was not able to consistently extract the DNA from the feed samples and did not achieve the criterion for accuracy for either the bovine or multispecies PCR primers. For the porcine primers, the method was validated, with four laboratories meeting the criterion for accuracy with an average accuracy of 99.2%. The fifth laboratory had a 93.3% accuracy outcome for the porcine primer. Collectively, these five laboratories had a 1.3% false-positive rate for the porcine primer. No laboratory was able to meet the criterion for accuracy with the ovine primers, most likely because of problems with the synthesis of the primer pair; none of the positive control DNA samples could be detected with the ovine primers. The multispecies primer pair was validated in three laboratories for use with bovine meat and bone meal and lamb meal but not with PMBM. The three laboratories had an average accuracy of 98.9% for bovine meat and bone meal, 97.8% for lamb meal, and 63.3% for PMBM. When examined on an individual laboratory basis, one of these four laboratories could not identify a single feed sample containing PMBM by using the multispecies primer, whereas the other laboratory identified only one PMBM-fortified sample, suggesting that the limit of detection for PMBM with this primer pair is around 0.1% (wt/wt). The results of this study demonstrated that the DNA forensic kit can be used to extract DNA from animal feed, which can then be used for PCR analysis to detect animal-derived protein present in the feed sample.

  20. Third party laboratory data management: Perspective with respect to clinical data management.

    PubMed

    Johnson, Jasmin; Kanagali, Vishwanath; Prabu, D

    2014-01-01

    Third party lab vendor provides support for laboratory, biological samples analytics data, collected during the clinical trial. Third party laboratory data is considered to be very significant for the clinical trial data management process. Although outsourcing these services is considered to be advantageous for clinical trials, there are some risks involved. Hence, pharmaceutical companies proactively select, track and evaluate third party vendors on a regular basis before, during and after the completion of the contract. The data manager has a significant role to play in effective management of third party vendor data.

Top