Sample records for sample collection operational

  1. Comparison of daily and weekly precipitation sampling efficiencies using automatic collectors

    USGS Publications Warehouse

    Schroder, L.J.; Linthurst, R.A.; Ellson, J.E.; Vozzo, S.F.

    1985-01-01

    Precipitation samples were collected for approximately 90 daily and 50 weekly sampling periods at Finley Farm, near Raleigh, North Carolina from August 1981 through October 1982. Ten wet-deposition samplers (AEROCHEM METRICS MODEL 301) were used; 4 samplers were operated for daily sampling, and 6 samplers were operated for weekly-sampling periods. This design was used to determine if: (1) collection efficiences of precipitation are affected by small distances between the Universal (Belfort) precipitation gage and collector; (2) measurable evaporation loss occurs and (3) pH and specific conductance of precipitation vary significantly within small distances. Average collection efficiencies were 97% for weekly sampling periods compared with the rain gage. Collection efficiencies were examined by seasons and precipitation volume. Neither factor significantly affected collection efficiency. No evaporation loss was found by comparing daily sampling to weekly sampling at the collection site, which was classified as a subtropical climate. Correlation coefficients for pH and specific conductance of daily samples and weekly samples ranged from 0.83 to 0.99.Precipitation samples were collected for approximately 90 daily and 50 weekly sampling periods at Finley farm, near Raleigh, North Carolina from August 1981 through October 1982. Ten wet-deposition samplers were used; 4 samplers were operated for daily sampling, and 6 samplers were operated for weekly-sampling periods. This design was used to determine if: (1) collection efficiencies of precipitation are affected by small distances between the University (Belfort) precipitation gage and collector; (2) measurable evaporation loss occurs and (3) pH and specific conductance of precipitation vary significantly within small distances.

  2. An innovative approach to sampling complex industrial emissions for use in animal toxicity tests: application to iron casting operations.

    PubMed

    Palmer, W G; Scholz, R C; Moorman, W J

    1983-03-01

    Sampling of complex mixtures of airborne contaminants for chronic animal toxicity tests often involves numerous sampling devices, requires extensive sampling time, and yields forms of collected materials unsuitable for administration to animals. A method is described which used a high volume, wet venturi scrubber for collection of respirable fractions of emissions from iron foundry casting operations. The construction and operation of the sampler are presented along with collection efficiency data and its application to the preparation of large quantities of samples to be administered to animals by intratracheal instillation.

  3. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF URINE SAMPLES (SOP-2.14)

    EPA Science Inventory

    This SOP describes the method for collecting urine samples from the study participants (children and their primary caregivers). Urine samples will be approximate 48-hr collections, collected as spot urine samples accumulated over the 48-hr sampling period. If the household or da...

  4. GeoLab 2011: New Instruments and Operations Tested at Desert RATS

    NASA Technical Reports Server (NTRS)

    Evans, Cindy A.; Calaway, M. J.; Bell, M. S.

    2012-01-01

    GeoLab is a geological laboratory and testbed designed for supporting geoscience activities during NASA's analog demonstrations. Scientists at NASA's Johnson Space Center built GeoLab as part of a technology project to aid the development of science operational concepts for future planetary surface missions [1, 2, 3]. It is integrated into NASA's Habitat Demonstration Unit, a first generation exploration habitat test article. As a prototype workstation, GeoLab provides a high fidelity working space for analog mission crewmembers to perform in-situ characterization of geologic samples and communicate their findings with supporting scientists. GeoLab analog operations can provide valuable data for assessing the operational and scientific considerations of surface-based geologic analyses such as preliminary examination of samples collected by astronaut crews [4, 5]. Our analog tests also feed into sample handling and advanced curation operational concepts and procedures that will, ultimately, help ensure that the most critical samples are collected during future exploration on a planetary surface, and aid decisions about sample prioritization, sample handling and return. Data from GeoLab operations also supports science planning during a mission by providing additional detailed geologic information to supporting scientists, helping them make informed decisions about strategies for subsequent sample collection opportunities.

  5. RECOMMENDED OPERATING PROCEDURE NO. 56: COLLECTION OF GASEOUS GRAB SAMPLES FROM COMBUSTION SOURCES FOR NITROUS OXIDE MEASUREMENT

    EPA Science Inventory

    The document is a recommended operating procedure, prepare or use in research activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). The procedure applies to the collection of gaseous grab samples from fossil fuel combustion sources for subsequent a...

  6. MAP3S precipitation chemistry network. Third periodic summary report, July 1978-December 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1980-05-01

    The MAP3S Precipitation Chemistry Network consists of eight collection sites in the northeastern United States. Precipitation event samples are collected by cooperating site operators, using specially developed sampling equipment. In this, the third periodic summary report, are listed field and concentration data for the period July 1, 1978 to December 31, 1979. Over three years' samples have been collected at most of the sites, which went into operation between September 1976 and October 1978. Samples are chemically analyzed at a central laboratory for 13 pollutant species. Weekly samples in addition to event samples were collected over a 1 1/2 yearmore » period at three sites. Analysis of one year's results indicates that there is little difference between the concentrations collected by the two methods in terms of seasonal precipitation-weighted means for all species except dissolved SO/sub 2/. Event samples tend to average about 25% higher in SO/sub 2/ than weekly samples.« less

  7. Salmonella Prevalence and Antimicrobial Susceptibility from the National Animal Health Monitoring System Sheep 2011 Study.

    PubMed

    Dargatz, David A; Marshall, Katherine L; Fedorka-Cray, Paula J; Erdman, Matthew M; Kopral, Christine A

    2015-12-01

    Salmonella is a major cause of foodborne illness and can cause clinical disease in animals. Understanding the on-farm ecology of Salmonella will be helpful in decreasing the risk of foodborne transmission. An objective of this study was to determine the prevalence of Salmonella among fecal samples collected on sheep operations in the United States. Another objective was to compare the use of composite fecal samples with fecal samples collected from individual sheep as a tool for screening sheep flocks for Salmonella. Sheep fecal samples (individual and composite) were collected on operations in 22 states. Salmonella isolates were characterized with regard to species, serotype, and antimicrobial susceptibility profile. Most operations (72.1%) had at least one positive sample and overall 26.9% of samples were positive. The percentage of positive samples varied by animal age class. Composite and individual samples gave similar results. The majority of the isolates (94%) were Salmonella enterica subspecies diarizonae serotype 61:-:1,5,7. Nearly all of the isolates (91.2%) tested for antimicrobial susceptibility were susceptible to all antimicrobials in the panel. The findings suggest that salmonellae typically associated with foodborne disease transmission are infrequently found on sheep operations in the United States.

  8. Legionnaires' Disease Bacteria in power plant cooling systems: downtime report. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyndall, R.L.; Solomon, J.A.; Christensen, S.W.

    1985-04-01

    Legionnaires' Disease Bacteria (Legionella) are a normal part of the aquatic community that, when aerosolized, can be pathogenic to man. The downtime study was designed to determine the degree to which Legionella populations are aerosolized during cleaning and maintenance operations in a closed-cycle steam-electric power plant. Both high-volume and impinger air samples were collected prior to and during downtime operations. Emphasis was placed on sampling inside or adjacent to water boxes, condensers, and cooling towers. Control air samples were taken upwind from the plant site. Water and sludge samples were also collected at various locations. In the laboratory, the concentrationsmore » of Groups A, B, and C Legionella were determined using the direct fluorescent antibody method. All positive air samples, and other selected air samples, were injected into guinea pigs to detect infectious Legionella. Legionella could be detected in only 12 of the 126 air samples collected. These were predominantly Group A Legionella (L. pneumophila, serogroups 1 to 6). All 12 positive samples had been collected in the vicinity of water boxes, condensers, detention ponds, and cooling towers during downtime operations where aerosolization of Legionella populations would be expected. None of the air samples yielded infectious Legionella when injected into guinea pigs. Detection of Legionella in air samples taken during downtime was significantly more likely than detection during normal operating conditions (p <0.01). 13 refs., 4 figs., 10 tabs.« less

  9. Audit of lymphadenectomy in lung cancer resections using a specimen collection kit and checklist

    PubMed Central

    Osarogiagbon, Raymond U.; Sareen, Srishti; Eke, Ransome; Yu, Xinhua; McHugh, Laura M.; Kernstine, Kemp H.; Putnam, Joe B.; Robbins, Edward T.

    2014-01-01

    Background Audits of operative summaries and pathology reports reveal wide discordance in identifying the extent of lymphadenectomy performed (the communication gap). We tested the ability of a pre-labeled lymph node specimen collection kit and checklist to narrow the communication gap between operating surgeons, pathologists, and auditors of surgeons’ operation notes. Methods We conducted a prospective single cohort study of lung cancer resections performed with a lymph node collection kit from November 2010 to January 2013. We used the kappa statistic to compare surgeon claims on a checklist of lymph node stations harvested intraoperatively, to pathology reports, and an independent audit of surgeons’ operative summaries. Lymph node collection procedures were classified into 4 groups based on the anatomic origin of resected lymph nodes: mediastinal lymph node dissection, systematic sampling, random sampling and no sampling. Results From the pathology report, 73% of 160 resections had a mediastinal lymph node dissection or systematic sampling procedure, 27% had random sampling. The concordance with surgeon claims was 80% (kappa statistic 0.69 [CI 0.60 – 0.79]). Concordance between independent audits of the operation notes and either the pathology report (kappa 0.14 [0.04 – 0.23]), or surgeon claims (kappa 0.09 [0.03 – 0.22]), was poor. Conclusion A pre-labeled specimen collection kit and checklist significantly narrowed the communication gap between surgeons and pathologists in identifying the extent of lymphadenectomy. Audit of surgeons’ operation notes did not accurately reflect the procedure performed, bringing its value for quality improvement work into question. PMID:25530090

  10. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE AND SHIPMENT OF URINE SAMPLES FOR SELECTED METALS AND PESTICIDES (UA-F-20.1)

    EPA Science Inventory

    The purpose of this SOP is to guide the collection, storage, and shipment of urine samples collected for the NHEXAS Arizona project. This SOP provides a brief description of sample, collection, preservation, storage, shipping, and custody procedures. This procedure was followed ...

  11. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR REIMBURSEMENT FOR FIELD COLLECTION OF DIET SAMPLES (UA-F-23.1)

    EPA Science Inventory

    The purpose of this SOP is to provide a uniform procedure for the financial reimbursement of primary respondents for the collection of diet samples. Respondents were reimbursed for replicate food and beverage samples by type and amount collected over a 24-hour sampling period. ...

  12. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR REIMBURSEMENT FOR FIELD COLLECTION OF FOOD SAMPLES (UA-F-23.1)

    EPA Science Inventory

    The purpose of this SOP is to provide a uniform procedure for the financial reimbursement of primary respondents for the collection of diet samples. Respondents were reimbursed for replicate food and beverage samples by type and amount collected over a 24-hour sampling period. ...

  13. Report of Operation FITZWILLIAM. Volume 1, Design of Operation and Summary of Results (REDACTED)

    DTIC Science & Technology

    1948-01-01

    storage tanks {400 lbs/sq in) to pel’mit the collection o£ sampleD or gas in the vicinity of the radio- active clouc1. P~dicective LUlC.lysis of -~he gas...Corps Furnish ground dust sampling units and wrap-around countera. 4. Navy Naval :Research Lab. (a) FW:-nish ground dust sampling units...direct as necessar,r the collection or air• craft filters and gaseou.s samples trca aircraft based at Km.falem. (6) Vector Destro,.er-M:lne...Swee

  14. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF URINE SAMPLES FOR METALS AND PESTICIDES ANALYSIS (UA-F-20.1)

    EPA Science Inventory

    The purpose of this SOP is to guide the collection, storage, and shipment of urine samples collected. This SOP provides a brief description of sample, collection, preservation, storage, shipping, and custody procedures. This procedure was followed to ensure consistent data retri...

  15. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF BLOOD SAMPLES FOR SELECTED METALS, PESTICIDES, AND VOCS (UA-F-19.1)

    EPA Science Inventory

    The purpose of this SOP is to guide the collection, storage, and shipment of blood samples collected. This SOP provides a brief description of sample collection, preservation, storage, and custody procedures. This procedure was followed to ensure consistent data retrieval during...

  16. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE AND SHIPMENT OF BLOOD SAMPLES FOR SELECTED METALS AND VOCS (UA-F-19.1)

    EPA Science Inventory

    The purpose of this SOP is to guide the collection, storage, and shipment of blood samples collected for the NHEXAS Arizona project. This SOP provides a brief description of sample collection, preservation, storage, and custody procedures. This procedure was followed to ensure c...

  17. NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF HAIR SAMPLES FOR TRACE METALS AND ARSENIC (RTI/ACS-209-046)

    EPA Science Inventory

    This protocol describes the procedures for the collection, storage, and shipping of human scalp hair samples for trace metals and arsenic or potential adduct analysis. Scalp hair samples were collected from each participant that agreed to provide the sample. Thinning shears were ...

  18. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF DISLODGEABLE RESIDUES -- PUF ROLLER SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.18)

    EPA Science Inventory

    This SOP describes the method to collect transferable residues from indoor floor surfaces. The sampling procedures described are applicable to bare floors or covered floor surfaces, e.g., carpeting and vinyl flooring. The samples will be collected only in the day care centers o...

  19. Audit of lymphadenectomy in lung cancer resections using a specimen collection kit and checklist.

    PubMed

    Osarogiagbon, Raymond U; Sareen, Srishti; Eke, Ransome; Yu, Xinhua; McHugh, Laura M; Kernstine, Kemp H; Putnam, Joe B; Robbins, Edward T

    2015-02-01

    Audits of operative summaries and pathology reports reveal wide discordance in identifying the extent of lymphadenectomy performed (the communication gap). We tested the ability of a prelabeled lymph node specimen collection kit and checklist to narrow the communication gap between operating surgeons, pathologists, and auditors of surgeons' operation notes. We conducted a prospective single cohort study of lung cancer resections performed with a lymph node collection kit from November 2010 to January 2013. We used the kappa statistic to compare surgeon claims on a checklist of lymph node stations harvested intraoperatively with pathology reports and an independent audit of surgeons' operative summaries. Lymph node collection procedures were classified into four groups based on the anatomic origin of resected lymph nodes: mediastinal lymph node dissection, systematic sampling, random sampling, and no sampling. From the pathology reports, 73% of 160 resections had a mediastinal lymph node dissection or systematic sampling procedure, 27% had random sampling. The concordance with surgeon claims was 80% (kappa statistic 0.69, 95% confidence interval: 0.60 to 0.79). Concordance between independent audits of the operation notes and either the pathology report (kappa 0.14, 95% confidence interval: 0.04 to 0.23) or surgeon claims (kappa 0.09, 95% confidence interval: 0.03 to 0.22) was poor. A prelabeled specimen collection kit and checklist significantly narrowed the communication gap between surgeons and pathologists in identifying the extent of lymphadenectomy. Audit of surgeons' operation notes did not accurately reflect the procedure performed, bringing its value for quality improvement work into question. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Retrospective testing and case series study of porcine delta coronavirus in U.S. swine herds.

    PubMed

    McCluskey, Brian J; Haley, Charles; Rovira, Albert; Main, Rodger; Zhang, Yan; Barder, Sunny

    2016-01-01

    Porcine deltacoronavirus (PDCoV) was first reported in the United States (US) in February 2014. This was the second novel swine enteric coronavirus detected in the US since May 2013. In this study, we conducted retrospective testing of samples submitted to three veterinary diagnostic laboratories where qualifying biological samples were derived from previously submitted diagnostic case submissions from US commercial swine farms with a clinical history of enteric disease or from cases that had been previously tested for transmissible gastroenteritis virus, PEDV, or rotavirus. Overall, 2286 banked samples were tested from 27 States. Samples were collected in 3 separate years and in 17 different months. Test results revealed 4 positive samples, 3 collected in August 2013 and 1 collected in October 2013. In addition, a case series including 42 operations in 10 States was conducted through administration of a survey. Survey data collected included information on characteristics of swine operations that had experienced PDCoV clinical signs. Special emphasis was placed on obtaining descriptive estimates of biosecurity practices and disease status over time of each operation. Clinical signs of PDCoV were reported to be similar to those of PEDV. The average number of animals on each operation exhibiting clinical signs (morbidity) and the average number of case fatalities was greatest for suckling and weaned pigs. Average operation-level weaned pig morbidity was greatest in the first week of the outbreak while average operation-level suckling pig case fatality was greatest in the second week of the outbreak. The survey included questions regarding biosecurity practices for visitors and operation employees; trucks, equipment and drivers; and feed sources. These questions attempted to identify a likely pathway of introduction of PDCoV onto the operations surveyed. Published by Elsevier B.V.

  1. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF URINE SAMPLES FOR METAL, PESTICIDE, AND CREATININE ANALYSIS (F10)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for collection, storage, and shipment of urine samples for metal, pesticides, and creatinine analysis. Samples were collected on Days 2 and 8 of each Cycle. The Day 2 sample was analyzed for metals and creatinine. The Day 8...

  2. Estimation of respirable dust exposure among coal miners in South Africa.

    PubMed

    Naidoo, Rajen; Seixas, Noah; Robins, Thomas

    2006-06-01

    The use of retrospective occupational hygiene data for epidemiologic studies is useful in determining exposure-outcome relationships, but the potential for exposure misclassification is high. Although dust sampling in the South African coal industry has been a legal requirement for several decades, these historical data are not readily adequate for estimating past exposures. This study describes the respirable coal mine dust levels in three South African coal mines over time. Each of the participating mining operations had well-documented dust sampling information that was used to describe historical trends in dust exposure. Investigator-collected personal dust samples were taken using standardized techniques from the face, backbye (underground jobs not at the coal face), and surface from 50 miners at each mine, repeated over three sampling cycles. Job histories and exposure information was obtained from a sample of 684 current miners and 188 ex-miners. Linear models were developed to estimate the exposure levels associated with work in each mine, exposure zone, and over time using a combination of operator-collected historical data and investigator-collected samples. The estimated levels were then combined with work history information to calculate cumulative exposure metrics for the miner cohort. The mean historical and investigator-collected respirable dust levels were within international norms and South African standards. Silica content of the dust samples was also below the 5% regulatory action level. Mean respirable dust concentrations at the face, based on investigator-collected samples, were 0.9 mg/m(3), 1.3 mg/m(3), and 1.9 mg/m(3) at Mines 1, 2, and 3, respectively. The operator-collected samples showed considerable variability across exposure zones, mines, and time, with the annual means at the face ranging from 0.4 mg/m(3) to 2.9 mg/m(3). Statistically significant findings were found between operator- and investigator-collected dust samples. Model-based arithmetic mean dust estimates at the face were 1.2 mg/m(3), 2.0 mg/m(3), and 0.9 mg/m(3) for Mines 1, 2, and 3, respectively. Using these levels, the mean cumulative exposure for the cohort was 56.8 mg-years/m(3). Current miners had a mean cumulative exposure of 66.5 mg-years/m(3), compared with ex-miners of 26.8 mg-years/m(3). Improvements in dust management or the use of different sampling equipment could account for the significant differences seen between operator- and investigator-collected data. Regression modeling for estimating mean dust levels over time using combined historical and investigator-collected data seems a reasonable method and useful in constructing models to describe cumulative exposures in a cohort of current and ex-miners.

  3. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FIELD COLLECTION OF YARD COMPOSITE SOIL SAMPLES (UA-F-5.1)

    EPA Science Inventory

    The purpose of this SOP is to establish a uniform procedure for the collection of yard composite soil samples in the field. This procedure was followed to ensure consistent and reliable collection of outdoor soil samples during the Arizona NHEXAS project and the "Border" study. ...

  4. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FIELD COLLECTION OF RESIDENTIAL FOUNDATION SOIL SAMPLES (UA-F-6.1)

    EPA Science Inventory

    The purpose of this SOP is to establish a uniform procedure for the collection of residential foundation soil samples in the field. This procedure was followed to ensure consistent and reliable collection of outdoor soil samples during the Arizona NHEXAS project and the "Border"...

  5. Tale of two sites: capillary versus arterial blood glucose testing in the operating room.

    PubMed

    Akinbami, Felix; Segal, Scott; Schnipper, Jeffrey L; Stopfkuchen-Evans, Matthias; Mills, Jonathan; Rogers, Selwyn O

    2012-04-01

    Pre- and intraoperative glycemic control has been identified as a putative target to improve outcomes of surgical patients. Glycemic control requires frequent monitoring of blood glucose levels with appropriate adjustments. However, monitoring standards have been called into question, especially in cases in which capillary samples are used. Point-of-care testing (POCT) using capillary samples and glucometers has been noted to give relatively accurate results for critically ill patients. However, the package inserts of most glucometers warn that they should not be used for patients in shock. This has led clinicians to doubt their accuracy in the operating room. The accuracy of capillary samples when tested in patients undergoing surgical procedures has not been proven. This study aims to determine the accuracy of intraoperative blood glucose values using capillary samples relative to arterial samples. A prospective study was conducted by collecting paired capillary and arterial samples of patients undergoing major operations at a tertiary medical center from August 2009 to May 2011. Subjects were a convenience sample of patients who had arterial lines and needed glucose testing while undergoing the procedure. Precision Xceed Pro (Abbott) handheld glucometers were used to obtain the blood glucose values. Our primary outcome of interest was the degree of correlation between capillary and arterial blood glucose values or the degree to which arterial glucose levels can be predicted by capillary glucose samples. We used linear regression and the Student t tests for statistical analyses. Seventy-two-paired samples were collected. Of the cases, 54% were major abdominal operations, whereas 24% were vascular operations. The mean values ± standard deviation for glucose levels were 146 ± 35 mg/dL (capillary) and 147 ± 36 mg/dL (arterial). The mean time ± standard deviation between the collection of both samples was 3.5 ± 1.3 minutes. The regression coefficient showed a strong positive correlation of .91 between capillary glucose values and arterial values (P < .001) although correlation was less stringent at the hyperglycemic range of values. The R(2) statistic was 84%. Differences in values between capillary and arterial samples would not have altered the diagnosis of hypo- and hyperglycemia using typical thresholds. Capillary samples collected intraoperatively are strongly correlated with arterial samples. Glucose monitoring in the operating room can be safely performed by collecting capillary samples for POCT. However, clinicians should still be cautious when interpreting glucose levels that are high, either by repeating the blood glucose test or by having samples sent to the laboratory. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Legionnaires' disease bacteria in power plant cooling systems: downtime report. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyndall, R.L.; Solomon, J.A.; Christensen, S.W.

    1985-11-01

    Legionnaires' disease bacteria (Legionella) are a normal part of the aquatic community that, when aerosolized, can be pathogenic to man. The downtime study was designed to determine the degree to which Legionella populations are aerosolized during cleaning and maintenance operations in a closed-cycle steam-electric power plant. Both high-volume and impinger air samples were collected prior to and during downtime operations. Emphasis was placed on sampling inside or adjacent to water boxes, condensers, and cooling towers. Control air samples were taken upwind from the plant site. Water and sludge samples were also collected at various locations. In the laboratory, the concentrationsmore » of Legionella were determined using the direct fluorescent antibody method. All positive air samples, and other selected air samples, were injected into guinea pigs to detect infectious Legionella. Legionella could be detected in only 12 of the 127 air samples collected. These were predominantly L. pneumophila, serogroups 1-6. In contrast to the air samples, most of the water and sludge samples were positive for Legionella, again predominantly L. pneumophila, serogroups 1-6. The highest Legionella concentrations were found in sludge samples associated with condenser tube cleaning. Among the water samples, the highest Legionella concentrations were found in cooling towers, immediately after the tower basins were cleaned and refilled, and in condenser tubes. Two of the three cooling tower water samples collected prior to downtime operations were infectious for guinea pigs. 16 refs., 4 figs., 11 tabs.« less

  7. Apparatus and process for collection of gas and vapor samples

    DOEpatents

    Jackson, Dennis G [Augusta, GA; Peterson, Kurt D [Aiken, SC; Riha, Brian D [Augusta, GA

    2008-04-01

    A gas sampling apparatus and process is provided in which a standard crimping tool is modified by an attached collar. The collar permits operation of the crimping tool while also facilitating the introduction of a supply of gas to be introduced into a storage vial. The introduced gas supply is used to purge ambient air from a collection chamber and an interior of the sample vial. Upon completion of the purging operation, the vial is sealed using the crimping tool.

  8. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR FIELD COLLECTION OF YARD COMPOSITE SOIL SAMPLES (UA-F-5.1)

    EPA Science Inventory

    The purpose of this SOP is to establish a uniform procedure for the collection of yard composite soil samples in the field. This procedure was followed to ensure consistent and reliable collection of outdoor soil samples during the Arizona NHEXAS project and the Border study. Ke...

  9. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF FLOOR DUST SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.19)

    EPA Science Inventory

    This SOP describes the method for collecting a floor dust sample from carpet. Dust samples will be collected in the room that the child uses most at home and/or at day care using a High Volume Small Surface Sampler (HVS3). In addition, participants will also be asked to donate a ...

  10. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF SOIL SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.20)

    EPA Science Inventory

    This SOP describes the method for collecting soil samples from the child's outdoor play area to measure for persistent organic pollutants. Soil samples are collected by scraping up the top 0.5 cm of soil in a 0.095 m2 (1 ft2) area in the middle of the child's play area.

  11. Mutagenicity of diesel exhaust particles from an engine with differing exhaust after treatments.

    PubMed

    Shi, X-C; Keane, M J; Ong, T; Li, S-Q; Bugarski, A B

    2010-01-01

    This study was conducted to investigate the effects of engine operating conditions and exhaust aftertreatments on the mutagenicity of diesel particulate matter (DPM) collected directly in an underground mine environment. A number of after-treatment devices are currently used on diesel engines in mines, but it is critical to determine whether reductions in DPM concentrations result in a corresponding decrease in adverse health effects. An eddy-current dynamometer was used to operate naturally aspirated mechanically controlled engine at several steady-state conditions. The samples were collected when the engine was equipped with a standard muffler, a diesel oxidation catalytic converter, two types of uncatalyzed diesel particulate filter systems, and three types of disposable diesel particulate filter elements. Bacterial gene mutation activity of DPM was tested on acetone extracts using the Ames Salmonella assay. The results indicated strong correlation between engine operating conditions and mutagenic activity of DPM. When the engine was fitted with muffler, the mutagenic activity was observed for the samples collected from light-load, but not heavy-load operating conditions. When the engine was equipped with a diesel oxidation catalyst, the samples did not exhibit mutagenic activity for any of four engine operating conditions. Mutagenic activity was observed for the samples collected when the engine was retrofitted with three types of disposable filters and sintered metal diesel particulate filter and operated at light load conditions. However, those filtration systems substantially reduced the concentration-normalized mutagenic activity from the levels observed for the muffler.

  12. Screening portal, system and method of using same

    DOEpatents

    Linker, Kevin L.; Hunter, John A.; Brusseau, Charles A.

    2013-04-30

    A portal, system and method for screening an object for a target substance is provided. The portal includes an inflatable bladder expandable to form a test space for receiving the object and a plurality of nozzles positioned about the inflatable bladder. The nozzles are in fluid communication with a fluid source for directing air over the object whereby samples are removed from the object for examination. A collector is operatively connected to the inflatable bladder for collecting the samples removed from the object. A detector is operatively connected to the collector for examining the removed samples for the presence of the target substance. At least one preconcentrator may be operatively connected to the collector for concentrating the samples collected thereby.

  13. 50 CFR 679.7 - Prohibitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... and the collection of scientific data or biological samples from the salmon has been completed. (B... scientific data or biological samples from the previous haul. (5) For the operator of a catcher vessel, to... count of salmon and the collection of scientific data or biological samples from the previous offload...

  14. 50 CFR 679.7 - Prohibitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... collection of scientific data or biological samples from the salmon has been completed. (B) Non-Chinook... scientific data or biological samples from the previous haul. (5) For the operator of a catcher vessel, to... count of salmon and the collection of scientific data or biological samples from the previous offload...

  15. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE AND SHIPMENT OF DRINKING AND TAP WATER SAMPLES FOR VOCS (EPA METHOD 524.2) (UA-F-18.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the collection, storage, and shipment of tap and drinking water samples for analysis by EPA method 524.2 (revision 4.0) for the NHEXAS Arizona project. This SOP provides a brief description of the sample containers, collection, preservation...

  16. 77 FR 59667 - Agency Information Collection Activities; Submission for OMB Review; Comment Request; Respirable...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-28

    ... for OMB Review; Comment Request; Respirable Coal Mine Dust Sampling ACTION: Notice. SUMMARY: The... information collection request (ICR) titled, ``Respirable Coal Mine Dust Sampling,'' to the Office of... operator to protect miners from exposure to excessive dust levels. The respirable coal mine dust sampling...

  17. Operational Procedures for Collecting Water-Quality Samples at Monitoring Sites on Maple Creek Near Nickerson and the Platte River at Louisville, Eastern Nebraska

    USGS Publications Warehouse

    Johnson, Steven M.; Swanson, Robert B.

    1994-01-01

    Prototype stream-monitoring sites were operated during part of 1992 in the Central Nebraska Basins (CNBR) and three other study areas of the National Water-Quality Assessment (NAWQ) Program of the U.S. Geological Survey. Results from the prototype project provide information needed to operate a net- work of intensive fixed station stream-monitoring sites. This report evaluates operating procedures for two NAWQA prototype sites at Maple Creek near Nickerson and the Platte River at Louisville, eastern Nebraska. Each site was sampled intensively in the spring and late summer 1992, with less intensive sampling in midsummer. In addition, multiple samples were collected during two high- flow periods at the Maple Creek site--one early and the other late in the growing season. Water-samples analyses included determination of pesticides, nutrients, major ions, suspended sediment, and measurements of physical properties. Equipment and protocols for the water-quality sampling procedures were evaluated. Operation of the prototype stream- monitoring sites included development and comparison of onsite and laboratory sample-processing proce- dures. Onsite processing was labor intensive but allowed for immediate preservation of all sampled constituents. Laboratory processing required less field labor and decreased the risk of contamination, but allowed for no immediate preservation of the samples.

  18. The Perils of Paul: Near Disasters in Airborne Radiochemical Sampling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meade, Roger Allen

    Beginning with the Trinity test in July 1945, Laboratory radiochemists have collected debris from nuclear tests by various means. At Trinity, two United States Army Sherman tanks were used. Beginning with Operation Crossroads and continuing throughout atmospheric testing, aircraft were used to fly in and around mushroom clouds to collect debris. Paul Guthals, the LASL project leader for sampling operations, flew on many of the B-57 sampling missions. Two such missions, one flown over the Nevada Test and one in the skies near Johnston Atoll, again proved the dangers involved in collecting airborne test debris. The events of these twomore » missions are briefly recounted.« less

  19. Establishment and operation of the National Accident Sampling System (NASS) team within the cities of Ft. Lauderdale/Hollywood, Florida

    NASA Astrophysics Data System (ADS)

    Beddow, B.; Roberts, C.; Rankin, J.; Bloch, A.; Peizer, J.

    1981-01-01

    The National Accident Sampling System (NASS) is described. The study area discussed is one of the original ten sites selected for NASS implementation. In addition to collecting data from the field, the original ten sites address questions of feasibility of the plan, projected results of the data collection effort, and specific operational topics, e.g., team size, sampling requirements, training approaches, quality control procedures, and field techniques. Activities and results of the first three years of the project, for both major tasks (establishment and operation) are addressed. Topics include: study area documentation; team description, function and activities; problems and solutions; and recommendations.

  20. Biobanking human endometrial tissue and blood specimens: standard operating procedure and importance to reproductive biology research and diagnostic development.

    PubMed

    Sheldon, Elizabeth; Vo, Kim Chi; McIntire, Ramsey A; Aghajanova, Lusine; Zelenko, Zara; Irwin, Juan C; Giudice, Linda C

    2011-05-01

    To develop a standard operating procedure (SOP) for collection, transport, storage of human endometrial tissue and blood samples, subject and specimen annotation, and establishing sample priorities. The SOP synthesizes sound scientific procedures, the literature on ischemia research, sample collection and gene expression profiling, good laboratory practices, and the authors' experience of workflow and sample quality. The National Institutes of Health, University of California, San Francisco, Human Endometrial Tissue and DNA Bank. Women undergoing endometrial biopsy or hysterectomy for nonmalignant indications. Collecting, processing, storing, distributing endometrial tissue and blood samples under approved institutional review board protocols and written informed consent from participating subjects. Standard operating procedure. The SOP addresses rigorous and consistent subject annotation, specimen processing and characterization, strict regulatory compliance, and a reference for researchers to track collection and storage times that may influence their research. The comprehensive and systematic approach to the procurement of human blood and endometrial tissue in this SOP ensures the high quality, reliability, and scientific usefulness of biospecimens made available to investigators by the National Institutes of Health, University of California, San Francisco, Human Endometrial Tissue and DNA Bank. The detail and perspective in this SOP also provides a blueprint for implementation of similar collection programs at other institutions. Copyright © 2011 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  1. The focus on sample quality: Influence of colon tissue collection on reliability of qPCR data

    PubMed Central

    Korenkova, Vlasta; Slyskova, Jana; Novosadova, Vendula; Pizzamiglio, Sara; Langerova, Lucie; Bjorkman, Jens; Vycital, Ondrej; Liska, Vaclav; Levy, Miroslav; Veskrna, Karel; Vodicka, Pavel; Vodickova, Ludmila; Kubista, Mikael; Verderio, Paolo

    2016-01-01

    Successful molecular analyses of human solid tissues require intact biological material with well-preserved nucleic acids, proteins, and other cell structures. Pre-analytical handling, comprising of the collection of material at the operating theatre, is among the first critical steps that influence sample quality. The aim of this study was to compare the experimental outcomes obtained from samples collected and stored by the conventional means of snap freezing and by PAXgene Tissue System (Qiagen). These approaches were evaluated by measuring rRNA and mRNA integrity of the samples (RNA Quality Indicator and Differential Amplification Method) and by gene expression profiling. The collection procedures of the biological material were implemented in two hospitals during colon cancer surgery in order to identify the impact of the collection method on the experimental outcome. Our study shows that the pre-analytical sample handling has a significant effect on the quality of RNA and on the variability of qPCR data. PAXgene collection mode proved to be more easily implemented in the operating room and moreover the quality of RNA obtained from human colon tissues by this method is superior to the one obtained by snap freezing. PMID:27383461

  2. Performance tasks for operator-skills research.

    DOT National Transportation Integrated Search

    1966-06-01

    The selection, development, and operation of several tasks for use in skilled-operator-performance research are described. The tasks are intended, collectively, to sample a broad spectrum of abilities required by complex operator systems; individuall...

  3. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF DRINKING AND TAP WATER SAMPLES FOR VOCS (EPA METHOD 524.2) ANALYSIS (UA-F-18.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the collection, storage, and shipment of tap and drinking water samples for analysis by EPA method 524.2 (revision 4.0). This SOP provides a brief description of the sample containers, collection, preservation, storage, shipping, and custod...

  4. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE AND SHIPMENT OF DRINKING AND TAP WATER SAMPLES FOR TRACE METALS (EPA METHOD 200.8) (UA-F-16.1)

    EPA Science Inventory

    The purpose of this SOP is to describe how to collect, store, and ship tap and drinking water samples for analysis by EPA Method 200.8 (revision 4.4) for the NHEXAS Arizona project. This SOP provides a brief description of the sample containers, collection, preservation, storage...

  5. Operational Cyber Testing Recommendations- Version 1

    DTIC Science & Technology

    2014-05-02

    be used to verify 5 representative pieces of the environment via sample test runs. Also, ideally, an early version of each test case can also be stood...extraneous effort). Comparing the sample results collected from the scripts with expected results can reveal deficiencies in the data collection techniques...the reporting mechanisms, and the system components themselves. The sample results can also be used for confirming that data is collected with high

  6. A review of international biobanks and networks: success factors and key benchmarks.

    PubMed

    Vaught, Jim; Kelly, Andrea; Hewitt, Robert

    2009-09-01

    Biobanks and biobanking networks are involved in varying degrees in the collection, processing, storage, and dissemination of biological specimens. This review outlines the approaches that 16 of the largest biobanks and biobanking networks in Europe, North America, Australia, and Asia have taken to collecting and distributing human research specimens and managing scientific initiatives while covering operating costs. Many are small operations that exist as either a single or a few freezers in a research laboratory, hospital clinical laboratory, or pathology suite. Larger academic and commercial biobanks operate to support large clinical and epidemiological studies. Operational and business models depend on the medical and research missions of their institutions and home countries. Some national biobanks operate with a centralized physical biobank that accepts samples from multiple locations. Others operate under a "federated" model where each institution maintains its own collections but agrees to list them on a central shared database. Some collections are "project-driven" meaning that specimens are collected and distributed to answer specific research questions. "General" collections are those that exist to establish a reference collection, that is, not to meet particular research goals but to be available to respond to multiple requests for an assortment of research uses. These individual and networked biobanking systems operate under a variety of business models, usually incorporating some form of partial cost recovery, while requiring at least partial public or government funding. Each has a well-defined biospecimen-access policy in place that specifies requirements that must be met-such as ethical clearance and the expertise to perform the proposed experiments-to obtain samples for research. The success of all of these biobanking models depends on a variety of factors including well-defined goals, a solid business plan, and specimen collections that are developed according to strict quality and operational controls.

  7. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FIELD COLLECTION OF INDOOR FLOOR SAMPLES AND POST FIELD SAMPLE HANDLING (UA-F-7.1)

    EPA Science Inventory

    The purpose of this SOP is to establish a uniform procedure for the collection of indoor floor dust samples in the field. This procedure was followed to ensure consistent data retrieval of dust samples during the Arizona NHEXAS project and the "Border" study. Keywords: field; va...

  8. Development of a standard operating procedure for the collection of pyrethroids in water and sediment matrices

    EPA Science Inventory

    Through a Regional Applied Research Effort grant to the United States Geological Survey, Region 9 collaborated with ORD on this project to develop a standard operating procedure for collection of water and sediment samples for pyrethroid analysis.

  9. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF FOOD PREPARATION SURFACE WIPE SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.17)

    EPA Science Inventory

    This SOP describes the method for collection of the food preparation surface wipe samples for the measurement of persistent organic pollutants (POP). This method uses a wipe to collect POP residues from a surface where a study participant prepares food the most often (i.e., kitch...

  10. A Comparison of Working Conditions Between Community College Instructors in Collective Bargaining Contract Colleges and Traditional Colleges.

    ERIC Educational Resources Information Center

    DePaoli, John A., Jr.

    In order to assess the impact of collective bargaining on community college faculty working conditions, a 79-item questionnaire was sent in winter 1974 to the presidents of a random nationwide sample of 100 community colleges operating under collective bargaining contracts and 100 community colleges operating under traditional agreements. Of the…

  11. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF DRINKING AND TAP WATER SAMPLES FOR TRACE METALS (EPA METHOD 200.8) ANALYSIS (UA-F-16.1)

    EPA Science Inventory

    The purpose of this SOP is to describe how to collect, store, and ship tap and drinking water samples for analysis by EPA Method 200.8 (revision 4.4) for the NHEXAS Arizona project. This SOP provides a brief description of the sample containers, collection, preservation, storage...

  12. NHEXAS PHASE I ARIZONA STUDY--LIST OF STANDARD OPERATING PROCEDURES

    EPA Science Inventory

    This document lists available protocols and SOPs for the NHEXAS Phase I Arizona study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis, (3) General laboratory procedures, (4) Quality Assurance, (...

  13. The Japanese Society of Pathology Guidelines on the handling of pathological tissue samples for genomic research: Standard operating procedures based on empirical analyses.

    PubMed

    Kanai, Yae; Nishihara, Hiroshi; Miyagi, Yohei; Tsuruyama, Tatsuhiro; Taguchi, Kenichi; Katoh, Hiroto; Takeuchi, Tomoyo; Gotoh, Masahiro; Kuramoto, Junko; Arai, Eri; Ojima, Hidenori; Shibuya, Ayako; Yoshida, Teruhiko; Akahane, Toshiaki; Kasajima, Rika; Morita, Kei-Ichi; Inazawa, Johji; Sasaki, Takeshi; Fukayama, Masashi; Oda, Yoshinao

    2018-02-01

    Genome research using appropriately collected pathological tissue samples is expected to yield breakthroughs in the development of biomarkers and identification of therapeutic targets for diseases such as cancers. In this connection, the Japanese Society of Pathology (JSP) has developed "The JSP Guidelines on the Handling of Pathological Tissue Samples for Genomic Research" based on an abundance of data from empirical analyses of tissue samples collected and stored under various conditions. Tissue samples should be collected from appropriate sites within surgically resected specimens, without disturbing the features on which pathological diagnosis is based, while avoiding bleeding or necrotic foci. They should be collected as soon as possible after resection: at the latest within about 3 h of storage at 4°C. Preferably, snap-frozen samples should be stored in liquid nitrogen (about -180°C) until use. When intending to use genomic DNA extracted from formalin-fixed paraffin-embedded tissue, 10% neutral buffered formalin should be used. Insufficient fixation and overfixation must both be avoided. We hope that pathologists, clinicians, clinical laboratory technicians and biobank operators will come to master the handling of pathological tissue samples based on the standard operating procedures in these Guidelines to yield results that will assist in the realization of genomic medicine. © 2018 The Authors. Pathology International published by Japanese Society of Pathology and John Wiley & Sons Australia, Ltd.

  14. United States Air Force Guide to Operational Surveillance of Medically Important Vectors and Pests Operational Entomology

    DTIC Science & Technology

    2006-08-15

    Programs Section 3. Sampling Equipment Sampling Equipment Solid-State Army Miniature (SSAM) trap ABC style trap Encephalitis Vector Survey Trap CDC...Baseline Survey - these are conducted to determine the types of vectors and pests occurring in the area of operations, their respective breeding sites...or source habitat, and seasonal activity patterns. Operational Survey - data collected in an operational survey are used specifically to aid pest

  15. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR FIELD COLLECTION AND POST-FIELD SAMPLE HANDLING OF INDOOR FLOOR DUST SAMPLES (UA-F-7.1)

    EPA Science Inventory

    The purpose of this SOP is to establish a uniform procedure for the collection of indoor floor dust samples in the field. This procedure was followed to ensure consistent data retrieval of dust samples during the Arizona NHEXAS project and the Border study. Keywords: field; vacu...

  16. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION OF PERSONAL AIR SAMPLES FOR ANALYSIS OF PESTICIDES OR METALS (UA-F-14.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedure for sampling personal air for metals and pesticides during a predetermined time period. The SOP includes the set up of the samplers for collection of either a metals sample or a pesticides sample, the calibration and initial c...

  17. Collective Negotiations and Teacher Satisfaction in Selected Indiana Secondary Schools.

    ERIC Educational Resources Information Center

    Davies, Paul R.; Kline, Charles E.

    This paper reports a study that sought to determine whether differences in bargaining procedures are related to differences in teacher satisfaction or morale. Of the forty schools in the random sample, 27 were operating under traditional collective negotiation procedures -- teachers relatively unorganized; eight were operating under procedural…

  18. 40 CFR 65.113 - Standards: Sampling connection systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... be collected or captured. (c) Equipment design and operation. Each closed-purge, closed-loop, or... system; or (2) Collect and recycle the purged process fluid to a process; or (3) Be designed and operated to capture and transport all the purged process fluid to a control device that meets the requirements...

  19. 40 CFR 65.113 - Standards: Sampling connection systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... be collected or captured. (c) Equipment design and operation. Each closed-purge, closed-loop, or... system; or (2) Collect and recycle the purged process fluid to a process; or (3) Be designed and operated to capture and transport all the purged process fluid to a control device that meets the requirements...

  20. 40 CFR 65.113 - Standards: Sampling connection systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... be collected or captured. (c) Equipment design and operation. Each closed-purge, closed-loop, or... system; or (2) Collect and recycle the purged process fluid to a process; or (3) Be designed and operated to capture and transport all the purged process fluid to a control device that meets the requirements...

  1. Automatic robotic arm operations and sampling in near zero gravity environment - functional tests results from Phobos-Grunt mission

    NASA Astrophysics Data System (ADS)

    Kozlova, Tatiana; Karol Seweryn, D..; Grygorczuk, Jerzy; Kozlov, Oleg

    The sample return missions have made a very significant progress to understanding of geology, the extra-terrestrial materials, processes occurring on surface and subsurface level, as well as of interactions between such materials and mechanisms operating there. The various sample return missions in the past (e.g. Apollo missions, Luna missions, Hayabusa mission) have provided scientists with samples of extra-terrestrial materials allowing to discover answers to critical scientific questions concerning the origin and evolution of the Solar System. Several new missions are currently planned: sample return missions, e.g Russian Luna-28, ESA Phootprint and MarcoPolo-R as well as both robotic and manned exploration missions to the Moon and Mars. One of the key challenges in such missions is the reliable sampling process which can be achieved by using many different techniques, e.g. static excavating technique (scoop), core drilling, sampling using dynamic mechanisms (penetrators), brushes and pneumatic systems. The effectiveness of any sampling strategy depends on many factors, including the required sample size, the mechanical and chemical soil properties (cohesive, hard or porous regolith, stones), the environment conditions (gravity, temperature, pressure, radiation). Many sampling mechanism have been studied, designed and built in the past, two techniques to collect regolith samples were chosen for the Phobos-Grunt mission. The proposed system consisted of a robotic arm with a 1,2m reach beyond the lander (IKI RAN); a tubular sampling device designed for collecting both regolith and small rock fragments (IKI RAN); the CHOMIK device (CBK PAN) - the low velocity penetrator with a single-sample container for collecting samples from the rocky surface. The functional tests were essential step in robotic arm, sampling device and CHOMIK device development process in the frame of Phobos-Grunt mission. Three major results were achieved: (i) operation scenario for autonomous sampling; (ii) technical characteristics of both devices, i.e. progress cycles of CHOMIK device in different materials and torque in the manipulator joints during sampling operations; (iii) confirmation of applicability of both devices to perform such type of tasks. The phases in operational scenario were prepared to meet mission and system requirements mainly connected with: (i) environment (near zero gravity, vacuum, dust), (ii) safety and (iii) to avoid common operation of both devices at the same time.

  2. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF DRINKING AND TAP WATER SAMPLES FOR PESTICIDES (EPA 225.2) AND CARBARYL (EPA 531.1) ANALYSIS (UA-F-17.1)

    EPA Science Inventory

    The purpose of this SOP is to describe how to collect, store, and ship tap and drinking water samples for analysis by EPA Method 525.2 (revision 1.0) and EPA method 531.1 (revision 3). This SOP provides a brief description of the sample containers, collection, preservation, stor...

  3. Cesium isotope ratios as indicators of nuclear power plant operations.

    PubMed

    Delmore, James E; Snyder, Darin C; Tranter, Troy; Mann, Nick R

    2011-11-01

    There are multiple paths by which radioactive cesium can reach the effluent from reactor operations. The radioactive (135)Cs/(137)Cs ratios are controlled by these paths. In an effort to better understand the origin of this radiation, these (135)Cs/(137)Cs ratios in effluents from three power reactor sites have been measured in offsite samples. These ratios are different from global fallout by up to six fold and as such cannot have a significant component from this source. A cesium ratio for a sample collected outside of the plant boundary provides integration over the operating life of the reactor. A sample collected inside the plant at any given time can be much different from this lifetime ratio. The measured cesium ratios vary significantly for the three reactors and indicate that the multiple paths have widely varying levels of contributions. There are too many ways these isotopes can fractionate to be useful for quantitative evaluations of operating parameters in an offsite sample, although it may be possible to obtain limited qualitative information for an onsite sample. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure with image analysis

    DOEpatents

    Van Berkel, Gary J.; Kertesz, Vilmos

    2011-08-09

    A system and method utilizes an image analysis approach for controlling the collection instrument-to-surface distance in a sampling system for use, for example, with mass spectrometric detection. Such an approach involves the capturing of an image of the collection instrument or the shadow thereof cast across the surface and the utilization of line average brightness (LAB) techniques to determine the actual distance between the collection instrument and the surface. The actual distance is subsequently compared to a target distance for re-optimization, as necessary, of the collection instrument-to-surface during an automated surface sampling operation.

  5. Ultra-wide Range Gamma Detector System for Search and Locate Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Odell, D. Mackenzie Odell; Harpring, Larry J.; Moore, Frank S. Jr.

    2005-10-26

    Collecting debris samples following a nuclear event requires that operations be conducted from a considerable stand-off distance. An ultra-wide range gamma detector system has been constructed to accomplish both long range radiation search and close range hot sample collection functions. Constructed and tested on a REMOTEC Andros platform, the system has demonstrated reliable operation over six orders of magnitude of gamma dose from 100's of uR/hr to over 100 R/hr. Functional elements include a remotely controlled variable collimator assembly, a NaI(Tl)/photomultiplier tube detector, a proprietary digital radiation instrument, a coaxially mounted video camera, a digital compass, and both local andmore » remote control computers with a user interface designed for long range operations. Long range sensitivity and target location, as well as close range sample selection performance are presented.« less

  6. Collection of Pyrethroids in Water and Sediment Matrices: Development and Validation of a Standard Operating Procedure

    USGS Publications Warehouse

    Hladik, Michelle; Orlando, James L.; Kuivila, Kathryn

    2009-01-01

    Loss of pyrethroid insecticides onto surfaces during sample collection can confound the interpretation of analytical and toxicity test results. Sample collection devices, container materials, and water matrix composition have a significant influence on the association of pyrethroids to container walls, which can be as high as 50 percent. Any sample collection method involving transfer through multiple containers or pieces of equipment increases the potential for pyrethroid loss. This loose 'surface-association' with container walls can be reversed through agitation. When sampling water matrices with pumps or autosamplers, no pyrethroids were lost as long as the water was moving continuously through the system. When collecting water matrices in containers, the material with the least amount of pyrethroid sorption is as follows: glass less than (<) plastic less than (<) Teflon. Additionally, pyrethroids were easier to re-suspend from the glass container walls. Since the amount of surface-association is proportional to the ratio of volume-to-contact-area of the sample, taking larger-volume field samples (greater than 3 liters) reduced pyrethroid losses to less than 10 percent. The amount of surface-association cannot be predicted easily because of the dependence on water matrix composition; samples with higher dissolved organic carbon or suspended-sediment concentrations were observed to have lower percent loss. Sediment samples were not affected by glass-container sorption (the only containers tested). Standardized sample-collection protocols are critical to yield accurate pyrethroid concentrations for assessment of potential effects, and have been summarized in an accompanying standard operating procedure.

  7. Pesticide-sampling equipment, sample-collection and processing procedures, and water-quality data at Chicod Creek, North Carolina, 1992

    USGS Publications Warehouse

    Manning, T.K.; Smith, K.E.; Wood, C.D.; Williams, J.B.

    1994-01-01

    Water-quality samples were collected from Chicod Creek in the Coastal Plain Province of North Carolina during the summer of 1992 as part of the U.S. Geological Survey's National Water-Quality Assessment Program. Chicod Creek is in the Albemarle-Pamlico drainage area, one of four study units designated to test equipment and procedures for collecting and processing samples for the solid-phase extraction of selected pesticides, The equipment and procedures were used to isolate 47 pesticides, including organonitrogen, carbamate, organochlorine, organophosphate, and other compounds, targeted to be analyzed by gas chromatography/mass spectrometry. Sample-collection and processing equipment equipment cleaning and set-up procedures, methods pertaining to collecting, splitting, and solid-phase extraction of samples, and water-quality data resulting from the field test are presented in this report Most problems encountered during this intensive sampling exercise were operational difficulties relating to equipment used to process samples.

  8. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--LIST OF STANDARD OPERATING PROCEDURES

    EPA Science Inventory

    This document lists available protocols and SOPs for the U.S.-Mexico Border Program study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis, (3) General laboratory procedures, (4) Quality Assuranc...

  9. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF BLOOD SAMPLES FOR METAL, PESTICIDE, PAH, VOC, AND LIPID ANALYSIS (F11)

    EPA Science Inventory

    The purpose of this SOP is to describe collection, storage, and shipment requirements of blood samples for metal, pesticide, polynuclear aromatic hydrocarbons (PAHs), volatile organic compound (VOC), and lipid analysis. Seven samples were taken from a single puncture: two 3-mL t...

  10. Measuring Water Quality in Hong Kong using an Underwater Remotely Operated Vehicle

    NASA Astrophysics Data System (ADS)

    Evans, J. W.

    2017-12-01

    Clean water is a vital necessity in our day to day lives, with all living organisms depending on it for survival and countless others relying on it as their habitat. The waters surrounding Hong Kong are home to a wide diversity of marine animals and organisms but are polluted for a variety of reasons. This pollution includes marine debris, industrial and construction waste, a high concentration of organic material, and other pollutants. This research project will focus on collecting water and soil samples from various locations around the Hong Kong ocean waters for analytical chemical sampling. A Remote Operated Vehicle (ROV) will be designed, built and used for collecting the water and soil samples. ROVs are used around the world in oceans and other deep water applications. ThisROV will be tethered with a control system and equipped with a camera, mechanical arms for collections water and soil samples and sensors for testing basic water parameters. Using a ROV will allow for long term sampling in the same location to occur as required. The collected samples will be tested in the lab to determine overall water and soil quality, allowing conclusions to be drawn about the conditions of the tested area.

  11. A perception and manipulation system for collecting rock samples

    NASA Technical Reports Server (NTRS)

    Choi, T.; Delingette, H.; Deluise, M.; Hsin, Y.; Hebert, M.; Ikeuchi, Katsushi

    1991-01-01

    An important part of a planetary exploration mission is to collect and analyze surface samples. As part of the Carnegie Mellon University Ambler Project, researchers are investigating techniques for collecting samples using a robot arm and a range sensor. The aim of this work is to make the sample collection operation fully autonomous. Described here are the components of the experimental system, including a perception module that extracts objects of interest from range images and produces models of their shapes, and a manipulation module that enables the system to pick up the objects identified by the perception module. The system was tested on a small testbed using natural terrain.

  12. Urine sampling and collection system optimization and testing

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Geating, J. A.; Koesterer, M. G.

    1975-01-01

    A Urine Sampling and Collection System (USCS) engineering model was developed to provide for the automatic collection, volume sensing and sampling of urine from each micturition. The purpose of the engineering model was to demonstrate verification of the system concept. The objective of the optimization and testing program was to update the engineering model, to provide additional performance features and to conduct system testing to determine operational problems. Optimization tasks were defined as modifications to minimize system fluid residual and addition of thermoelectric cooling.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leishear, R.; Thaxton, D.; Minichan, R.

    A sampling tool was required to evaluate residual activity ({mu}Curies per square foot) on the inner wall surfaces of underground nuclear waste storage tanks. The tool was required to collect a small sample from the 3/8 inch thick tank walls. This paper documents the design, testing, and deployment of the remotely operated sampling device. The sampler provides material from a known surface area to estimate the overall surface contamination in the tank prior to closure. The sampler consisted of a sampler and mast assembly mast assembly, control system, and the sampler, or end effector, which is defined as the operatingmore » component of a robotic arm. The mast assembly consisted of a vertical 30 feet long, 3 inch by 3 inch, vertical steel mast and a cantilevered arm hinged at the bottom of the mast and lowered by cable to align the attached sampler to the wall. The sampler and mast assembly were raised and lowered through an opening in the tank tops, called a riser. The sampler is constructed of a mounting plate, a drill, springs to provide a drive force to the drill, a removable sampler head to collect the sample, a vacuum pump to draw the sample from the drill to a filter, and controls to operate the system. Once the sampler was positioned near the wall, electromagnets attached it to the wall, and the control system was operated to turn on the drill and vacuum to remove and collect a sample from the wall. Samples were collected on filters in removable sampler heads, which were readily transported for further laboratory testing.« less

  14. 40 CFR 63.1013 - Sampling connection systems standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) National Emission Standards for Equipment Leaks-Control Level 1 § 63.1013 Sampling connection... container are not required to be collected or captured. (c) Equipment design and operation. Each closed... process fluid to a process; or (3) Be designed and operated to capture and transport all the purged...

  15. Process test plan, phase II: waste retrieval sluicing system emissions collection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    POWERS, R.L.

    1999-06-01

    This Process Test Plan is prepared to continue from HNF-3733 which was Phase I of the test. Supplemental operational controls and sampling requirements are defined to safely obtain gas samples from the 296-C-006 ventilation system stack during active operation of the sluicing equipment.

  16. 77 FR 36567 - Agency Information Collection Activities: Application and Approval To Manipulate, Examine, Sample...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-19

    ... information (total capital/startup costs and operations and maintenance costs). The comments that are... collection with no change to the burden hours or to the information collected. Type of Review: Extension...

  17. Air-conditioning vs. presence of pathogenic fungi in hospital operating theatre environment.

    PubMed

    Gniadek, Agnieszka; Macura, Anna B

    2011-01-01

    Infections related to modern surgical procedures present a difficult problem for contemporary medicine. Infections acquired during surgery represent a risk factor related to therapeutical interventions. Eradication of microorganisms from hospital operating theatre environment may contribute to reduction of infections as the laminar flow air-conditioning considerably reduces the number of microorganisms in the hospital environment. The objective of the study was to evaluate the occurrence of fungi in air-conditioned operating theatre rooms. The study was carried out in one of the hospitals in Krak6w during December 2009. Indoor air samples and imprints from the walls were collected from five operating theatre rooms. A total of fifty indoor air samples were collected with a MAS-100 device, and twenty five imprints from the walls were collected using a Count Tact method. Fungal growth was observed in 48 air samples; the average numbers of fungi were within the range of 5-100 c.f.u. in one cubic metre of the air. Fungi were detected only in four samples of the wall imprints; the number of fungi was 0.01 c.f.u. per one square centimetre of the surface. The mould genus Aspergillus was most frequently isolated, and the species A. fumigatus and A. versicolor were the dominating ones. To ensure microbiological cleanness of hospital operating theatre, the air-conditioning system should be properly maintained. Domination of the Aspergillus fungi in indoor air as well as increase in the number of moulds in the samples taken in evenings (p < 0.05) may suggest that the room decontamination procedures were neglected.

  18. Comparing Apollo and Mars Exploration Rover (MER) Operations Paradigms for Human Exploration During NASA Desert-Rats Science Operations

    NASA Technical Reports Server (NTRS)

    Yingst, R. A.; Cohen, B. A.; Ming, D. W.; Eppler, D. B.

    2011-01-01

    NASA's Desert Research and Technology Studies (D-RATS) field test is one of several analog tests that NASA conducts each year to combine operations development, technology advances and science under planetary surface conditions. The D-RATS focus is testing preliminary operational concepts for extravehicular activity (EVA) systems in the field using simulated surface operations and EVA hardware and procedures. For 2010 hardware included the Space Exploration Vehicles, Habitat Demonstration Units, Tri-ATHLETE, and a suite of new geology sample collection tools, including a self-contained GeoLab glove box for conducting in-field analysis of various collected rock samples. The D-RATS activities develop technical skills and experience for the mission planners, engineers, scientists, technicians, and astronauts responsible for realizing the goals of exploring planetary surfaces.

  19. U.S. Geological Survey Catskill/Delaware Water-Quality Network: Water-Quality Report Water Year 2006

    USGS Publications Warehouse

    McHale, Michael R.; Siemion, Jason

    2010-01-01

    The U.S. Geological Survey operates a 60-station streamgaging network in the New York City Catskill/Delaware Water Supply System. Water-quality samples were collected at 13 of the stations in the Catskill/Delaware streamgaging network to provide resource managers with water-quality and water-quantity data from the water-supply system that supplies about 85 percent of the water needed by the more than 9 million residents of New York City. This report summarizes water-quality data collected at those 13 stations plus one additional station operated as a part of the U.S. Environmental Protection Agency's Regional Long-Term Monitoring Network for the 2006 water year (October 1, 2005 to September 30, 2006). An average of 62 water-quality samples were collected at each station during the 2006 water year, including grab samples collected every other week and storm samples collected with automated samplers. On average, 8 storms were sampled at each station during the 2006 water year. The 2006 calendar year was the second warmest on record and the summer of 2006 was the wettest on record for the northeastern United States. A large storm on June 26-28, 2006, caused extensive flooding in the western part of the network where record peak flows were measured at several watersheds.

  20. Soil Sampling Operating Procedure

    EPA Pesticide Factsheets

    EPA Region 4 Science and Ecosystem Support Division (SESD) document that describes general and specific procedures, methods, and considerations when collecting soil samples for field screening or laboratory analysis.

  1. Sediment Sampling Operating Procedure

    EPA Pesticide Factsheets

    EPA Region 4 Science and Ecosystem Support Division (SESD) document that describes general and specific procedures, methods, and considerations when collecting sediment samples for field screening or laboratory analysis.

  2. [Establishment and Management of Multicentral Collection Bio-sample Banks of Malignant Tumors from Digestive System].

    PubMed

    Shen, Si; Shen, Junwei; Zhu, Liang; Wu, Chaoqun; Li, Dongliang; Yu, Hongyu; Qiu, Yuanyuan; Zhou, Yi

    2015-11-01

    To establish and manage of multicentral collection bio-sample banks of malignant tumors from digestive system, the paper designed a multicentral management system, established the standard operation procedures (SOPs) and leaded ten hospitals nationwide to collect tumor samples. The biobank has been established for half a year, and has collected 695 samples from patients with digestive system malignant tumor. The clinical data is full and complete, labeled in a unified way and classified to be managed. The clinical and molecular biology researches were based on the biobank, and obtained achievements. The biobank provides a research platform for malignant tumor of digestive system from different regions and of different types.

  3. Automated biowaste sampling system urine subsystem operating model, part 1

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Rosen, F.

    1973-01-01

    The urine subsystem automatically provides for the collection, volume sensing, and sampling of urine from six subjects during space flight. Verification of the subsystem design was a primary objective of the current effort which was accomplished thru the detail design, fabrication, and verification testing of an operating model of the subsystem.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Puls, R.W.; Powell, R.M.

    R.S. Kerr Environmental Research Laboratory (RSKERL) personnel have evaluated sampling procedures for the collection of representative, accurate, and reproducible ground water quality samples for metals for the past four years. Intensive sampling research at three different field sites has shown that the method by which samples are collected has a greater impact on sample quality, accuracy, and reproducibility than whether the samples are filtered or not. In particular, sample collection practices that induce artifically high levels of turbidity have been shown to have the greatest negative impacts on sample quality. Results indicated the ineffectiveness of bailer for collection of representativemore » metal samples. Inconsistent operator usage together with excessive purging generally resulted in excessive turbidity and large differences in filtered and unfiltered metal samples. The use of low flow rate purging and sampling consistently produced filtered and unfiltered samples that showed no significant differences in concentrations. Turbidity levels were generally less than 5 NTUs, even in fine-textured glacial till. The authors recommend the use of low flow rates, during both purging and sampling.« less

  5. HINTS Puerto Rico: Final Report

    Cancer.gov

    This final report describes HINTS implementation in Puerto Rico. The report addresses sampling; staffing, training and management of data collection; calling protocol; findings from the CATI Operations, and sample weights.

  6. Soil Gas Sampling Operating Procedure

    EPA Pesticide Factsheets

    EPA Region 4 Science and Ecosystem Support Division (SESD) document that describes general and specific procedures, methods, and considerations when collecting soil gas samples for field screening or laboratory analysis.

  7. Reconnaissance of Organic Wastewater Compounds at a Concentrated Swine Feeding Operation in the North Carolina Coastal Plain, 2008

    USGS Publications Warehouse

    Harden, Stephen L.

    2009-01-01

    Water-quality and hydrologic data were collected during 2008 to examine the occurrence of organic wastewater compounds at a concentrated swine feeding operation located in the North Carolina Coastal Plain. Continuous groundwater level and stream-stage data were collected at one monitoring well and one stream site, respectively, throughout 2008. One round of environmental and quality-control samples was collected in September 2008 following a period of below-normal precipitation and when swine waste was not being applied to the spray fields. Samples were collected at one lagoon site, seven shallow groundwater sites, and one surface-water site for analysis of 111 organic wastewater compounds, including household, industrial, and agricultural-use compounds, sterols, pharmaceutical compounds, hormones, and antibiotics. Analytical data for environmental samples collected during the study provide preliminary information on the occurrence of organic wastewater compounds in the lagoon-waste source material, groundwater beneath fields that receive spray applications of the lagoon wastes, and surface water in the tributary adjacent to the site. Overall, 28 organic wastewater compounds were detected in the collected samples, including 11 household, industrial, and agricultural-use compounds; 3 sterols; 2 pharmaceutical compounds; 5 hormones; and 7 antibiotics. The lagoon sample had the greatest number (20) and highest concentrations of compounds compared to groundwater and surface-water samples. The antibiotic lincomycin had the maximum detected concentration (393 micrograms per liter) in the lagoon sample. Of the 11 compounds identified in the groundwater and surface-water samples, all with reported concentrations less than 1 microgram per liter, only lincomycin identified in groundwater at 1 well and 3-methyl-1H-indole and indole identified in surface water at 1 site also were identified in the lagoon waste material.

  8. Use of Electronic Hand-held Devices for Collection of Savannah River Site Environmental Data - 13329

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marberry, Hugh; Moore, Winston

    2013-07-01

    Savannah River Nuclear Solutions has begun using Xplore Tablet PC's to collect data in the field for soil samples, groundwater samples, air samples and round sheets at the Savannah River Site (SRS). EPA guidelines for groundwater sampling are incorporated into the application to ensure the sample technician follows the proper protocol. The sample technician is guided through the process for sampling and round sheet data collection by a series of menus and input boxes. Field measurements and well stabilization information are entered into the tablet for uploading into Environmental Restoration Data Management System (ERDMS). The process helps to eliminate inputmore » errors and provides data integrity. A soil sample technician has the ability to collect information about location of sample, field parameter, describe the soil sample, print bottle labels, and print chain of custody for the sample that they have collected. An air sample technician has the ability to provide flow, pressure, hours of operation, print bottle labels and chain of custody for samples they collect. Round sheets are collected using the information provided in the various procedures. The data are collected and uploaded into ERDMS. The equipment used is weather proof and hardened for the field use. Global Positioning System (GPS) capabilities are integrated into the applications to provide the location where samples were collected and to help sample technicians locate wells that are not visited often. (authors)« less

  9. Apollo Saturn 511 effluent measurements from the Apollo 16 launch operations: An experiment

    NASA Technical Reports Server (NTRS)

    Gregory, G. L.; Hulten, W. C.; Wornom, D. E.

    1974-01-01

    An experiment was performed in conjunction with the Apollo 16 launch to define operational and instrumentational problems associated with launch-vehicle exhaust effluent monitoring. Ground and airborne sampling were performed for CO, CO2, hydrocarbons, and particulates. Sampling systems included filter pads and photometers for particulates and whole-air grab samples for gases. Launch debris was identified in the particulate samples at ground level(taken immediately after launch) and in the airborne measurements (taken 40 to 50 minutes after launch approximately 40 km downwind of the pad). Operational problems were identified and included the need for higher instrumentation mobility and the need for real-time sampling instrumentation as opposed to collection-type samples such as the whole-air grab sample.

  10. NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE--HUMAN BIOLOGICAL MARKERS:BLOOD AND URINE SAMPLE COLLECTION AND ANALYSES (EOHSI-AP-209-040)

    EPA Science Inventory

    This procedure describes the process for collecting and analyzing blood and urine samples. The presence of chemical contaminants in biological specimens such as blood, urine, and hair represent a measure of the internal dose or body burden for a given individual derived from the ...

  11. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION OF SURFACE WIPE SAMPLES FOR PESTICIDES OR METALS (UA-F-8.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for collecting surface wipe samples inside a home for analysis of either metals or pesticides. This procedure covers the preparation of the surface wipe material and field activities. This protocol was followed to ensure con...

  12. CTEPP STANDARD OPERATING PROCEDURE FOR HANDLING MISSING SAMPLES AND DATA (SOP-2.24)

    EPA Science Inventory

    This SOP describes the method for handling missing samples or data. Missing samples or data will be identified as soon as possible during field sampling. It provides guidance to collect the missing sample or data and document the reason for the missing sample or data.

  13. Rain sampling device

    DOEpatents

    Nelson, D.A.; Tomich, S.D.; Glover, D.W.; Allen, E.V.; Hales, J.M.; Dana, M.T.

    1991-05-14

    The present invention constitutes a rain sampling device adapted for independent operation at locations remote from the user which allows rainfall to be sampled in accordance with any schedule desired by the user. The rain sampling device includes a mechanism for directing wet precipitation into a chamber, a chamber for temporarily holding the precipitation during the process of collection, a valve mechanism for controllably releasing samples of the precipitation from the chamber, a means for distributing the samples released from the holding chamber into vessels adapted for permanently retaining these samples, and an electrical mechanism for regulating the operation of the device. 11 figures.

  14. Rain sampling device

    DOEpatents

    Nelson, Danny A.; Tomich, Stanley D.; Glover, Donald W.; Allen, Errol V.; Hales, Jeremy M.; Dana, Marshall T.

    1991-01-01

    The present invention constitutes a rain sampling device adapted for independent operation at locations remote from the user which allows rainfall to be sampled in accordance with any schedule desired by the user. The rain sampling device includes a mechanism for directing wet precipitation into a chamber, a chamber for temporarily holding the precipitation during the process of collection, a valve mechanism for controllably releasing samples of said precipitation from said chamber, a means for distributing the samples released from the holding chamber into vessels adapted for permanently retaining these samples, and an electrical mechanism for regulating the operation of the device.

  15. Colling Wipe Samples for VX Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koester, C; Hoppes, W G

    2010-02-11

    This standard operating procedure (SOP) provides uniform procedures for the collection of wipe samples of VX residues from surfaces. Personnel may use this procedure to collect and handle wipe samples in the field. Various surfaces, including building materials (wood, metal, tile, vinyl, etc.) and equipment, may be sampled based on this procedure. The purpose of such sampling is to determine whether or not the relevant surfaces are contaminated, to determine the extent of their contamination, to evaluate the effectiveness of decontamination procedures, and to determine the amount of contaminant that might present as a contact hazard.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Copeland, Timothy; Putnam, Scott

    The goal of Idaho Steelhead Monitoring and Evaluation Studies is to collect monitoring data to evaluate wild and natural steelhead populations in the Clearwater and Salmon river drainages. During 2007, intensive population data were collected in Fish Creek (Lochsa River tributary) and Rapid River (Little Salmon River tributary); extensive data were collected in other selected spawning tributaries. Weirs were operated in Fish Creek and Rapid River to estimate adult escapement and to collect samples for age determination and genetic analysis. Snorkel surveys were conducted in Fish Creek, Rapid River, and Boulder Creek (Little Salmon River tributary) to estimate parr density.more » Screw traps were operated in Fish Creek, Rapid River, Secesh River, and Big Creek to estimate juvenile emigrant abundance, to tag fish for survival estimation, and to collect samples for age determination and genetic analysis. The estimated wild adult steelhead escapement in Fish Creek was 81 fish and in Rapid River was 32 fish. We estimate that juvenile emigration was 24,127 fish from Fish Creek; 5,632 fish from Rapid River; and 43,674 fish from Big Creek. The Secesh trap was pulled for an extended period due to wildfires, so we did not estimate emigrant abundance for that location. In cooperation with Idaho Supplementation Studies, trap tenders PIT tagged 25,618 steelhead juveniles at 18 screw trap sites in the Clearwater and Salmon river drainages. To estimate age composition, 143 adult steelhead and 5,082 juvenile steelhead scale samples were collected. At the time of this report, 114 adult and 1,642 juvenile samples have been aged. Project personnel collected genetic samples from 122 adults and 839 juveniles. We sent 678 genetic samples to the IDFG Eagle Fish Genetics Laboratory for analysis. Water temperature was recorded at 37 locations in the Clearwater and Salmon river drainages.« less

  17. An operation manual for a time-series, storm-activated suspended sediment sampler deployed in the coastal ocean: function, maintenance, and testing procedures

    USGS Publications Warehouse

    Rendigs, Richard R.; Bothner, Michael H.

    2004-01-01

    This manual describes the operation and testing procedures for two models of a multi-port suspended sediment sampler that are moored in the coastal ocean and that collect samples on a programmable time schedule that can be interrupted to collect during a storm. The ability to sense and collect samples before, during, and after the height of a storm is a unique feature of these instruments because it provides samples during conditions when it is difficult or impossible to sample from a surface ship. The sensors used to trigger storm sampling are a transmissometer or a pressure sensor. The purpose of such samples is to assess composition and concentration of sediment resuspended from the seafloor during storms and subsequently transported within the coastal system. Both light transmission and the standard deviation of pressure from surface waves correlate with the passage of major storms. The instruments successfully identified the onset of storms and collected samples before, during, and after the storm maximum as programmed. The accuracy of determining suspended matter concentrations collected by the sediment sampler has not been fully evaluated. Preliminary laboratory tests using a suspension of muddy sediment collected in a near-bottom sediment trap yielded excellent results. However in laboratory tests with different sediment types, the suspended matter concentrations determined with these samplers became less accurate with increasing average grain size. Future calibration work is necessary and should be conducted in a facility that ideally has a water depth of at least 30 feet to prevent cavitation of the pump that draws sea water through the filters. The test facility should also have the capability for adding suspended matter of known composition and concentration to a fixed volume of seawater that is well mixed.

  18. Gerst and Swanson perform blood draw in Columbus module

    NASA Image and Video Library

    2014-06-04

    Astronaut Alexander Gerst,Expedition 40 flight engineer (background),and Expedition 40 Commander Steve Swanson are photographed performing blood sample collection in the Columbus module as part of HRF Generic Frozen Blood Collection Operations.

  19. A prioritization and analysis strategy for environmental surveillance results.

    PubMed

    Shyr, L J; Herrera, H; Haaker, R

    1997-11-01

    DOE facilities are required to conduct environmental surveillance to verify that facility operations are operated within the approved risk envelope and have not caused undue risk to the public and the environment. Given a reduced budget, a strategy for analyzing environmental surveillance data was developed to set priorities for sampling needs. The radiological and metal data collected at Sandia National Laboratories, New Mexico, were used to demonstrate the analysis strategy. Sampling locations were prioritized for further investigation and the needs for routine sampling. The process of data management, analysis, prioritization, and presentation has been automated through a custom-designed computer tool. Data collected over years can be analyzed and summarized in a short table format for prioritization and decision making.

  20. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR FIELD COLLECTION OF FOOD AND BEVERAGE SAMPLES (UA-F-15.1)

    EPA Science Inventory

    The purpose of this SOP is to provide a uniform procedure for the collection of a complete (all meals, snacks, and beverages), one-day (24 hour) duplicate diet sample from the primary respondent. Participants will keep a duplicate portion of all food consumed in a 24 hour period...

  1. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION OF SURFACE WIPE SAMPLES FOR PESTICIDES OR METALS ANALYSIS (UA-F-8.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for collecting surface wipe samples inside a home for analysis of either metals or pesticides. This procedure covers the preparation of the surface wipe material and field activities. This protocol was followed to ensure con...

  2. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION OF DERMAL WIPE SAMPLES FOR PESTICIDES OR METALS (UA-F-9.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for collecting a dermal wipe sample from a participant's hands for the measurement of pesticide or metal residues on the skin. This procedure covers the preparation of the dermal wipe material and field activities. This prot...

  3. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FIELD COLLECTION OF FOOD AND BEVERAGE SAMPLES (UA-F-15.1)

    EPA Science Inventory

    The purpose of this SOP is to provide a uniform procedure for the collection of a complete (all meals, snacks, and beverages), one-day (24 hour) duplicate diet sample from the primary respondent. Participants will keep a duplicate portion of all food consumed in a 24 hour period...

  4. Aerosol Sampling Experiment on the International Space Station

    NASA Technical Reports Server (NTRS)

    Meyer, Marit E.

    2017-01-01

    The International Space Station (ISS) is a unique indoor environment which serves as both home and workplace to the astronaut crew. There is currently no particulate monitoring, although particulate matter requirements exist. An experiment to collect particles in the ISS cabin was conducted recently. Two different aerosol samplers were used for redundancy and to collect particles in two size ranges spanning from 10 nm to hundreds of micrometers. The Active Sampler is a battery operated thermophoretic sampler with an internal pump which draws in air and collects particles directly on a transmission electron microscope grid. This commercial-off-the-shelf device was modified for operation in low gravity. The Passive Sampler has five sampling surfaces which were exposed to air for different durations in order to collect at least one sample with an optimal quantity of particles for microscopy. These samples were returned to Earth for analysis with a variety of techniques to obtain long-term average concentrations and identify particle emission sources. Results are compared with the inventory of ISS aerosols which was created based on sparse data and the literature. The goal of the experiment is to obtain data on indoor aerosols on ISS for future particulate monitor design and development.

  5. Synchronous in-field application of life-detection techniques in planetary analog missions

    NASA Astrophysics Data System (ADS)

    Amador, Elena S.; Cable, Morgan L.; Chaudry, Nosheen; Cullen, Thomas; Gentry, Diana; Jacobsen, Malene B.; Murukesan, Gayathri; Schwieterman, Edward W.; Stevens, Adam H.; Stockton, Amanda; Yin, Chang; Cullen, David C.; Geppert, Wolf

    2015-02-01

    Field expeditions that simulate the operations of robotic planetary exploration missions at analog sites on Earth can help establish best practices and are therefore a positive contribution to the planetary exploration community. There are many sites in Iceland that possess heritage as planetary exploration analog locations and whose environmental extremes make them suitable for simulating scientific sampling and robotic operations. We conducted a planetary exploration analog mission at two recent lava fields in Iceland, Fimmvörðuháls (2010) and Eldfell (1973), using a specially developed field laboratory. We tested the utility of in-field site sampling down selection and tiered analysis operational capabilities with three life detection and characterization techniques: fluorescence microscopy (FM), adenine-triphosphate (ATP) bioluminescence assay, and quantitative polymerase chain reaction (qPCR) assay. The study made use of multiple cycles of sample collection at multiple distance scales and field laboratory analysis using the synchronous life-detection techniques to heuristically develop the continuing sampling and analysis strategy during the expedition. Here we report the operational lessons learned and provide brief summaries of scientific data. The full scientific data report will follow separately. We found that rapid in-field analysis to determine subsequent sampling decisions is operationally feasible, and that the chosen life detection and characterization techniques are suitable for a terrestrial life-detection field mission. In-field analysis enables the rapid obtainment of scientific data and thus facilitates the collection of the most scientifically relevant samples within a single field expedition, without the need for sample relocation to external laboratories. The operational lessons learned in this study could be applied to future terrestrial field expeditions employing other analytical techniques and to future robotic planetary exploration missions.

  6. CTEPP STANDARD OPERATING PROCEDURE FOR SETTING UP A HOUSEHOLD SAMPLING SCHEDULE (SOP-2.10)

    EPA Science Inventory

    This SOP describes the method for scheduling study subjects for field sampling activities in North Carolina (NC) and Ohio (OH). There are three field sampling teams with two staff members on each team. Two field sampling teams collect the field data simultaneously. A third fiel...

  7. Automated biowaste sampling system, solids subsystem operating model, part 2

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Stauffer, R. E.

    1973-01-01

    The detail design and fabrication of the Solids Subsystem were implemented. The system's capacity for the collection, storage or sampling of feces and vomitus from six subjects was tested and verified.

  8. Evaluation of standardized sample collection, packaging, and ...

    EPA Pesticide Factsheets

    Journal Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures.

  9. Advanced Navigation Strategies for an Asteroid Sample Return Mission

    NASA Technical Reports Server (NTRS)

    Bauman, J.; Getzandanner, K.; Williams, B.; Williams, K.

    2011-01-01

    The proximity operations phases of a sample return mission to an asteroid have been analyzed using advanced navigation techniques derived from experience gained in planetary exploration. These techniques rely on tracking types such as Earth-based radio metric Doppler and ranging, spacecraft-based ranging, and optical navigation using images of landmarks on the asteroid surface. Navigation strategies for the orbital phases leading up to sample collection, the touch down for collecting the sample, and the post sample collection phase at the asteroid are included. Options for successfully executing the phases are studied using covariance analysis and Monte Carlo simulations of an example mission to the near Earth asteroid 4660 Nereus. Two landing options were studied including trajectories with either one or two bums from orbit to the surface. Additionally, a comparison of post-sample collection strategies is presented. These strategies include remaining in orbit about the asteroid or standing-off a given distance until departure to Earth.

  10. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE AND SHIPMENT OF DRINKING AND TAP WATER SAMPLES FOR PESTICIDES (EPA 225.2) AND CARBARYL (EPA 531.1) (UA-F-17.1)

    EPA Science Inventory

    The purpose of this SOP is to describe how to collect, store, and ship tap and drinking water samples for analysis by EPA Method 525.2 (revision 1.0) and EPA method 531.1 (revision 3) for the NHEXAS Arizona project. This SOP provides a brief description of the sample containers,...

  11. Fully automatic characterization and data collection from crystals of biological macromolecules.

    PubMed

    Svensson, Olof; Malbet-Monaco, Stéphanie; Popov, Alexander; Nurizzo, Didier; Bowler, Matthew W

    2015-08-01

    Considerable effort is dedicated to evaluating macromolecular crystals at synchrotron sources, even for well established and robust systems. Much of this work is repetitive, and the time spent could be better invested in the interpretation of the results. In order to decrease the need for manual intervention in the most repetitive steps of structural biology projects, initial screening and data collection, a fully automatic system has been developed to mount, locate, centre to the optimal diffraction volume, characterize and, if possible, collect data from multiple cryocooled crystals. Using the capabilities of pixel-array detectors, the system is as fast as a human operator, taking an average of 6 min per sample depending on the sample size and the level of characterization required. Using a fast X-ray-based routine, samples are located and centred systematically at the position of highest diffraction signal and important parameters for sample characterization, such as flux, beam size and crystal volume, are automatically taken into account, ensuring the calculation of optimal data-collection strategies. The system is now in operation at the new ESRF beamline MASSIF-1 and has been used by both industrial and academic users for many different sample types, including crystals of less than 20 µm in the smallest dimension. To date, over 8000 samples have been evaluated on MASSIF-1 without any human intervention.

  12. The WAIS Melt Monitor: An automated ice core melting system for meltwater sample handling and the collection of high resolution microparticle size distribution data

    NASA Astrophysics Data System (ADS)

    Breton, D. J.; Koffman, B. G.; Kreutz, K. J.; Hamilton, G. S.

    2010-12-01

    Paleoclimate data are often extracted from ice cores by careful geochemical analysis of meltwater samples. The analysis of the microparticles found in ice cores can also yield unique clues about atmospheric dust loading and transport, dust provenance and past environmental conditions. Determination of microparticle concentration, size distribution and chemical makeup as a function of depth is especially difficult because the particle size measurement either consumes or contaminates the meltwater, preventing further geochemical analysis. Here we describe a microcontroller-based ice core melting system which allows the collection of separate microparticle and chemistry samples from the same depth intervals in the ice core, while logging and accurately depth-tagging real-time electrical conductivity and particle size distribution data. This system was designed specifically to support microparticle analysis of the WAIS Divide WDC06A deep ice core, but many of the subsystems are applicable to more general ice core melting operations. Major system components include: a rotary encoder to measure ice core melt displacement with 0.1 millimeter accuracy, a meltwater tracking system to assign core depths to conductivity, particle and sample vial data, an optical debubbler level control system to protect the Abakus laser particle counter from damage due to air bubbles, a Rabbit 3700 microcontroller which communicates with a host PC, collects encoder and optical sensor data and autonomously operates Gilson peristaltic pumps and fraction collectors to provide automatic sample handling, melt monitor control software operating on a standard PC allowing the user to control and view the status of the system, data logging software operating on the same PC to collect data from the melting, electrical conductivity and microparticle measurement systems. Because microparticle samples can easily be contaminated, we use optical air bubble sensors and high resolution ice core density profiles to guide the melting process. The combination of these data allow us to analyze melt head performance, minimize outer-to-inner fraction contamination and avoid melt head flooding. The WAIS Melt Monitor system allows the collection of real-time, sub-annual microparticle and electrical conductivity data while producing and storing enough sample for traditional Coulter-Counter particle measurements as well long term acid leaching of bioactive metals (e.g., Fe, Co, Cd, Cu, Zn) prior to chemical analysis.

  13. DEVELOPMENT, EVALUATION AND APPLICATION OF AN AUTOMATED EVENT PRECIPITATION SAMPLER FOR NETWORK OPERATION

    EPA Science Inventory

    In 1993, the University of Michigan Air Quality Laboratory (UMAQL) designed a new wet-only precipitation collection system that was utilized in the Lake Michigan Loading Study. The collection system was designed to collect discrete mercury and trace element samples on an event b...

  14. Microbial and Nutrient Concentration and Load Data During Stormwater Runoff at a Swine Concentrated Animal Feeding Operation in the North Carolina Coastal Plain, 2006-2007

    USGS Publications Warehouse

    Harden, Stephen L.

    2008-01-01

    This report summarizes water-quality and hydrologic data collected during 2006-2007 to characterize bacteria and nutrient loads associated with overland runoff and subsurface tile drainage in spray fields at a swine concentrated animal feeding operation. Four monitoring locations were established at the Lizzie Research Site in the North Carolina Coastal Plain Physiographic Province for collecting discharge and water-quality data during stormwater-runoff events. Water stage was measured continuously at each monitoring location. A stage-discharge relation was developed for each site and was used to compute instantaneous discharge values for collected samples. Water-quality samples were collected for five storm events during 2006-2007 for analysis of nutrients and fecal indicator bacteria. Instantaneous loads of nitrite plus nitrate, total coliform, Escherichia coli (E. coli), and enterococci were computed for selected times during the five storm events.

  15. Standard operating procedures for collection of soil and sediment samples for the Sediment-bound Contaminant Resiliency and Response (SCoRR) strategy pilot study

    USGS Publications Warehouse

    Fisher, Shawn C.; Reilly, Timothy J.; Jones, Daniel K.; Benzel, William M.; Griffin, Dale W.; Loftin, Keith A.; Iwanowicz, Luke R.; Cohl, Jonathan A.

    2015-12-17

    An understanding of the effects on human and ecological health brought by major coastal storms or flooding events is typically limited because of a lack of regionally consistent baseline and trends data in locations proximal to potential contaminant sources and mitigation activities, sensitive ecosystems, and recreational facilities where exposures are probable. In an attempt to close this gap, the U.S. Geological Survey (USGS) has implemented the Sediment-bound Contaminant Resiliency and Response (SCoRR) strategy pilot study to collect regional sediment-quality data prior to and in response to future coastal storms. The standard operating procedure (SOP) detailed in this document serves as the sample-collection protocol for the SCoRR strategy by providing step-by-step instructions for site preparation, sample collection and processing, and shipping of soil and surficial sediment (for example, bed sediment, marsh sediment, or beach material). The objectives of the SCoRR strategy pilot study are (1) to create a baseline of soil-, sand-, marsh sediment-, and bed-sediment-quality data from sites located in the coastal counties from Maine to Virginia based on their potential risk of being contaminated in the event of a major coastal storm or flooding (defined as Resiliency mode); and (2) respond to major coastal storms and flooding by reoccupying select baseline sites and sampling within days of the event (defined as Response mode). For both modes, samples are collected in a consistent manner to minimize bias and maximize quality control by ensuring that all sampling personnel across the region collect, document, and process soil and sediment samples following the procedures outlined in this SOP. Samples are analyzed using four USGS-developed screening methods—inorganic geochemistry, organic geochemistry, pathogens, and biological assays—which are also outlined in this SOP. Because the SCoRR strategy employs a multi-metric approach for sample analyses, this protocol expands upon and reconciles differences in the sample collection protocols outlined in the USGS “National Field Manual for the Collection of Water-Quality Data,” which should be used in conjunction with this SOP. A new data entry and sample tracking system also is presented to ensure all relevant data and metadata are gathered at the sample locations and in the laboratories.

  16. INNOVATIVE TECHNOLOGY EVALUATION REPORT ...

    EPA Pesticide Factsheets

    The Russian Peat Borer designed and fabricated by Aquatic Research Instruments was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation Program in April and May 1999 at sites in EPA Regions 1 and 5, respectively. In addition to assessing ease of sampler operation, key objectives of the demonstration included evaluating the sampler?s ability to (1) consistently collect a given volume of sediment, (2) consistently collect sediment in a given depth interval, (3) collect samples with consistent characteristics from a homogenous layer of sediment, and (4) collect samples under a variety of site conditions. This report describes the demonstration results for the Russian Peat Borer and two conventional samplers (the Hand Corer and Vibrocorer) used as reference samplers. During the demonstration, the Russian Peat Borer was the only sampler that collected samples in the deep depth interval (4 to 11 feet below sediment surface). It collected representative and relatively uncompressed core samples of consolidated sediment in discrete depth intervals. The reference samplers collected relatively compressed samples of both consolidated and unconsolidated sediments from the sediment surface downward; sample representativeness may be questionable because of core shortening and core compression. Sediment stratification was preserved only for consolidated sediment samples collected by the Russian Peat Borer but for bo

  17. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION OF DERMAL WIPE SAMPLES FOR PESTICIDES AND METALS ANALYSIS (UA-F-9.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for collecting a dermal wipe sample from a participant's hands for the measurement of pesticide or metal residues on the skin. This procedure covers the preparation of the dermal wipe material and field activities. This prot...

  18. Biobanking of different body fluids within the frame of IVF-a standard operating procedure to improve reproductive biology research.

    PubMed

    Schenk, Michael; Huppertz, Berthold; Obermayer-Pietsch, Barbara; Kastelic, Darja; Hörmann-Kröpfl, Martina; Weiss, Gregor

    2017-02-01

    The aim of the present study was to develop a standard operating procedure (SOP) for the collection, transport, and storage of human cumulus cells, follicular fluid, blood serum, seminal plasma, embryo culture supernatant, and embryo culture supernatant control obtained within the IVF process under approved protocols and written informed consent from participating patients. The SOP was developed at the Kinderwunsch Institut Schenk, Dobl, Austria, together with Biobank Graz of the Medical University of Graz, Austria. The SOP provides comprehensive details of laboratory procedures and sampling of the different fluids within the IVF process. Furthermore, information on sample coding, references of involved laboratory techniques (e.g., oocyte retrieval with a Steiner-TAN needle), ethical approvals, and biobanking procedures are presented. The result of the present study is a standard operating procedure. The SOP ensures a professional way for collection and scientific use of IVF samples by the Kinderwunsch Institut Schenk, Dobl, Austria, and Biobank Graz of the Medical University of Graz, Austria. It can be used as a template for other institutions to unify specimen collection procedures in the field of reproductive health research.

  19. Fluid sampling tool

    DOEpatents

    Garcia, Anthony R.; Johnston, Roger G.; Martinez, Ronald K.

    2000-01-01

    A fluid-sampling tool for obtaining a fluid sample from a container. When used in combination with a rotatable drill, the tool bores a hole into a container wall, withdraws a fluid sample from the container, and seals the borehole. The tool collects fluid sample without exposing the operator or the environment to the fluid or to wall shavings from the container.

  20. Field guide for collecting and processing stream-water samples for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.

    1994-01-01

    The U.S. Geological Survey's National Water-Quality Assessment program includes extensive data- collection efforts to assess the quality of the Nations's streams. These studies require analyses of stream samples for major ions, nutrients, sediments, and organic contaminants. For the information to be comparable among studies in different parts of the Nation, consistent procedures specifically designed to produce uncontaminated samples for trace analysis in the laboratory are critical. This field guide describes the standard procedures for collecting and processing samples for major ions, nutrients, organic contaminants, sediment, and field analyses of conductivity, pH, alkalinity, and dissolved oxygen. Samples are collected and processed using modified and newly designed equipment made of Teflon to avoid contamination, including nonmetallic samplers (D-77 and DH-81) and a Teflon sample splitter. Field solid-phase extraction procedures developed to process samples for organic constituent analyses produce an extracted sample with stabilized compounds for more accurate results. Improvements to standard operational procedures include the use of processing chambers and capsule filtering systems. A modified collecting and processing procedure for organic carbon is designed to avoid contamination from equipment cleaned with methanol. Quality assurance is maintained by strict collecting and processing procedures, replicate sampling, equipment blank samples, and a rigid cleaning procedure using detergent, hydrochloric acid, and methanol.

  1. Research on Navy-Related Combat Casualty Care Issues, Navy Operational-Related Injuries and Illnesses and Approaches to Enhance Navy/Marine Corps Personnel Combat Performance.

    DTIC Science & Technology

    1998-06-01

    role of bone morphogenetic protein (BMP) receptors in bone regeneration in periodontal tissues . Tissue samples for these studies are in the accrual...34 Characterization of Bone Morphogenetic Protein Receptors in Oral Tissues " collection of clinical samples will proceed in preparation for assay. • Relative to the...transcribed. • Relative to the project * Characterization of Bone Morphogenetic Protein Receptors in Oral Tissues ", collection of clinical samples is

  2. NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE--SAMPLE SHIPPING PROCEDURES (RTI/ACS-AP-209-083)

    EPA Science Inventory

    This procedure summarizes the sample shipping procedures that have been described in the individual NHEXAS sample collection protocols. This procedure serves as a quick reference tool for the field staff when samples are prepared for shipment at the field lab/staging area. For ea...

  3. CTEPP STANDARD OPERATING PROCEDURE FOR HANDLING SAMPLE AND DATA CUSTODY (SOP-2.26)

    EPA Science Inventory

    This SOP describes the method for handling sample custody. A standardized Chain-of-Custody (CoC) Record is used to document the sample/data custody. Each participant is assigned one CoC Record for the samples/data collected at their home and/or day care center.

  4. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR DUPLICATE SAMPLING (F12)

    EPA Science Inventory

    This SOP is designed to provide both general and specific guidance for the collection of duplicate samples by Harvard School of Public Health/Emory University for the NHEXAS project. The purpose of the duplicate sampling was to ensure that the value obtained for a sample was ind...

  5. Fully automatic characterization and data collection from crystals of biological macromolecules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Svensson, Olof; Malbet-Monaco, Stéphanie; Popov, Alexander

    A fully automatic system has been developed that performs X-ray centring and characterization of, and data collection from, large numbers of cryocooled crystals without human intervention. Considerable effort is dedicated to evaluating macromolecular crystals at synchrotron sources, even for well established and robust systems. Much of this work is repetitive, and the time spent could be better invested in the interpretation of the results. In order to decrease the need for manual intervention in the most repetitive steps of structural biology projects, initial screening and data collection, a fully automatic system has been developed to mount, locate, centre to themore » optimal diffraction volume, characterize and, if possible, collect data from multiple cryocooled crystals. Using the capabilities of pixel-array detectors, the system is as fast as a human operator, taking an average of 6 min per sample depending on the sample size and the level of characterization required. Using a fast X-ray-based routine, samples are located and centred systematically at the position of highest diffraction signal and important parameters for sample characterization, such as flux, beam size and crystal volume, are automatically taken into account, ensuring the calculation of optimal data-collection strategies. The system is now in operation at the new ESRF beamline MASSIF-1 and has been used by both industrial and academic users for many different sample types, including crystals of less than 20 µm in the smallest dimension. To date, over 8000 samples have been evaluated on MASSIF-1 without any human intervention.« less

  6. INNOVATIVE TECHNOLOGY EVALUATION REPORT ...

    EPA Pesticide Factsheets

    The Split Core Sampler for Submerged Sediments (Split Core Sampler) designed and fabricated by Arts Manufacturing & Supply, Inc., was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation Program in April and May 1999 at sites in EPA Regions 1 and 5, respectively. In addition to assessing ease of sampler operation, key objectives of the demonstration included evaluating the samplers ability to (1) consistently collect a given volume of sediment, (2) consistently collect sediment in a given depth interval, (3) collect samples with consistent characteristics from a homogenous layer of sediment, and (4) collect samples under a variety of site conditions. This report describes the demonstration results for the Split Core Sampler and two conventional samplers (the Hand Corer and Vibrocorer) used as reference samplers. During the demonstration, the Split Core Sampler performed as well as or better than the reference samplers. Based on visual observations, both the Split Core Sampler and reference samplers collected partially compressed samples of consolidated and unconsolidated sediments from the sediment surface downward; sample representativeness may be questionable because of core shortening and core compression. Sediment stratification was preserved for both consolidated and unconsolidated sediment samples collected by the Split Core Sampler and reference samplers. No sampler was able to collect samples

  7. Whole Air Sampling During NASA's March-April 1999 Pacific Exploratory Expedition (PEM-Tropics B)

    NASA Technical Reports Server (NTRS)

    Blake, Donald R.

    2001-01-01

    University of California, Irvine (UCI) collected more than 4500 samples whole air samples collected over the remote Pacific Ocean during NASA's Global Tropospheric Experiment (GTE) Pacific Exploratory Mission-Tropics B (PEM-Tropics B) in March and early April 1999. Approximately 140 samples during a typical 8-hour DC-8 flight, and 120 canisters for each 8-hour flight aboard the P-3B. These samples were obtained roughly every 3-7 min during horizontal flight legs and 1-3 min during vertical legs. The filled canisters were analyzed in the laboratory at UCI within ten days of collection. The mixing ratios of 58 trace gases comprising hydrocarbons, halocarbons, alkyl nitrates and DMS were reported (and archived) for each sample. Two identical analytical systems sharing the same standards were operated simultaneously around the clock to improve canister turn-around time and to keep our measurement precision optimal. This report presents a summary of the results for sample collected.

  8. Archaeological Investigations at Sites 45-OK-250 and 45-OK-4, Chief Joseph Dam Project, Washington.

    DTIC Science & Technology

    1984-01-01

    level behind Chief Joseph Dam. Systematic random sampling using I x I x ’ - 0.1-m collection units in 1 x 1, 1 x 2, or 2 x 2 m cel Is disclosed...ft to the operating pool . level behind Chief Joseph Dam. Systematic random sampling using 1 x 1 x 0.1-i collection units In 1 x 1, 1 x 2, or 2 x 2 m...contingencies under which data were collected , describe data collection and analysis, and organize and summarize data In a torm useful to the widest

  9. Matrix isolation apparatus with extended sample collection capability

    DOEpatents

    Reedy, Gerald T.

    1987-01-01

    A gas-sample collection device provides for the matrix isolation of increased amounts of a sample material for spectrographic analysis from a gas chromatographic separation. The device includes an evacuated sample collection chamber containing a disc-like specular carousel having a generally circular lateral surface upon which the sample is deposited in an inert gas matrix for infrared (IR) spectral analysis. The evacuated sample chamber is mounted in a fixed manner and is coupled to and supports a rotating cryostatic coupler which, in turn, supports the specular carousel within the collection chamber. A rotational drive system connected to the cryostatic coupler provides for its rotational displacement as well as that of the sample collecting carousel. In addition, rotation of the cryostatic coupler effects vertical displacement of the carousel to permit the collection of an extended sample band in a helical configuration on the entire lateral surface of the carousel. The various components of the carousel's angular/linear displacement drive system are located exterior to the cryostatic coupler for easy access and improved operation. The cryostatic coupler includes a 360.degree. rotary union assembly for permitting the delivery of a high pressure working fluid to the cryostatic coupler in a continuous flow manner for maintaining the specular carousel at a low temperature, e.g., 10.degree.-20.degree. K., for improved uninterrupted gas sample collection and analysis.

  10. Estimating time-dependent ROC curves using data under prevalent sampling.

    PubMed

    Li, Shanshan

    2017-04-15

    Prevalent sampling is frequently a convenient and economical sampling technique for the collection of time-to-event data and thus is commonly used in studies of the natural history of a disease. However, it is biased by design because it tends to recruit individuals with longer survival times. This paper considers estimation of time-dependent receiver operating characteristic curves when data are collected under prevalent sampling. To correct the sampling bias, we develop both nonparametric and semiparametric estimators using extended risk sets and the inverse probability weighting techniques. The proposed estimators are consistent and converge to Gaussian processes, while substantial bias may arise if standard estimators for right-censored data are used. To illustrate our method, we analyze data from an ovarian cancer study and estimate receiver operating characteristic curves that assess the accuracy of the composite markers in distinguishing subjects who died within 3-5 years from subjects who remained alive. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  11. Tear cytokine profile as a noninvasive biomarker of inflammation for ocular surface diseases: standard operating procedures.

    PubMed

    Wei, Yi; Gadaria-Rathod, Neha; Epstein, Seth; Asbell, Penny

    2013-12-23

    To provide standard operating procedures (SOPs) for measuring tear inflammatory cytokine concentrations and to validate the resulting profile as a minimally invasive objective metric and biomarker of ocular surface inflammation for use in multicenter clinical trials on dry eye disease (DED). Standard operating procedures were established and then validated with cytokine standards, quality controls, and masked tear samples collected from local and distant clinical sites. The concentrations of the inflammatory cytokines in tears were quantified using a high-sensitivity human cytokine multiplex kit. A panel of inflammatory cytokines was initially investigated, from which four key inflammatory cytokines (IL-1β, IL-6, INF-γ, and TNF-α) were chosen. Results with cytokine standards statistically satisfied the manufacturer's quality control criteria. Results with pooled tear samples were highly reproducible and reliable with tear volumes ranging from 4 to 10 μL. Incorporation of the SOPs into clinical trials was subsequently validated. Tear samples were collected at a distant clinical site, stored, and shipped to our Biomarker Laboratory, where a masked analysis of the four tear cytokines was successfully performed. Tear samples were also collected from a feasibility study on DED. Inflammatory cytokine concentrations were decreased in tears of subjects who received anti-inflammatory treatment. Standard operating procedures for human tear cytokine assessment suitable for multicenter clinical trials were established. Tear cytokine profiling using these SOPs may provide objective metrics useful for diagnosing, classifying, and analyzing treatment efficacy in inflammatory conditions of the ocular surface, which may further elucidate the mechanisms involved in the pathogenesis of ocular surface disease.

  12. A precision multi-sampler for deep-sea hydrothermal microbial mat studies

    NASA Astrophysics Data System (ADS)

    Breier, J. A.; Gomez-Ibanez, D.; Reddington, E.; Huber, J. A.; Emerson, D.

    2012-12-01

    A new tool was developed for deep-sea microbial mat studies by remotely operated vehicles and was successfully deployed during a cruise to the hydrothermal vent systems of the Mid-Cayman Rise. The Mat Sampler allows for discrete, controlled material collection from complex microbial structures, vertical-profiling within thick microbial mats and particulate and fluid sample collection from venting seafloor fluids. It has a reconfigurable and expandable sample capacity based on magazines of 6 syringes, filters, or water bottles. Multiple magazines can be used such that 12-36 samples can be collected routinely during a single dive; several times more if the dive is dedicated for this purpose. It is capable of hosting in situ physical, electrochemical, and optical sensors, including temperature and oxygen probes in order to guide sampling and to record critical environmental parameters at the time and point of sample collection. The precision sampling capability of this instrument will greatly enhance efforts to understand the structured, delicate, microbial mat communities that grow in diverse benthic habitats.

  13. Clean and Cold Sample Curation

    NASA Technical Reports Server (NTRS)

    Allen, C. C.; Agee, C. B.; Beer, R.; Cooper, B. L.

    2000-01-01

    Curation of Mars samples includes both samples that are returned to Earth, and samples that are collected, examined, and archived on Mars. Both kinds of curation operations will require careful planning to ensure that the samples are not contaminated by the instruments that are used to collect and contain them. In both cases, sample examination and subdivision must take place in an environment that is organically, inorganically, and biologically clean. Some samples will need to be prepared for analysis under ultra-clean or cryogenic conditions. Inorganic and biological cleanliness are achievable separately by cleanroom and biosafety lab techniques. Organic cleanliness to the <50 ng/sq cm level requires material control and sorbent removal - techniques being applied in our Class 10 cleanrooms and sample processing gloveboxes.

  14. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF HUMAN HAIR (UA-F-26.0)

    EPA Science Inventory

    The purpose of this SOP is to describe how to collect, store, and ship human hair for analysis of mercury. This SOP provides a brief description of the sample containers, collection, storage, shipping and custody procedures. This procedure was followed to ensure consistent data ...

  15. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF UNKNOWN SUBSTANCES (UA-F-25.0)

    EPA Science Inventory

    The purpose of this SOP is to describe how to collect, store, and ship unknown substances for chemical analysis and identification. This SOP provides a brief description of the sample containers, collection, storage, shipping and custody procedures. This procedure was followed ...

  16. Microbial contamination of meat during the skinning of beef carcass hindquarters at three slaughtering plants.

    PubMed

    Gill, C O; McGinnis, J C; Bryant, J

    1998-07-21

    The microbiological effects on the product of the series of operations for skinning the hindquarters of beef carcasses at three packing plants were assessed. Samples were obtained at each plant from randomly selected carcasses, by swabbing specified sites related to opening cuts, rump skinning or flank skinning operations, randomly selected sites along the lines of the opening cuts, or randomly selected sites on the skinned hindquarters of carcasses. A set of 25 samples of each type was collected at each plant, with the collection of a single sample from each selected carcass. Aerobic counts, coliforms and Escherichia coli were enumerated in each sample, and a log mean value was estimated for each set of 25 counts on the assumption of a log normal distribution of the counts. The data indicated that the hindquarters skinning operations at plant A were hygienically inferior to those at the other two plants, with mean numbers of coliforms and E. coli being about two orders of magnitude greater, and aerobic counts being an order of magnitude greater on the skinned hindquarters of carcasses from plant A than on those from plants B or C. The data further indicated that the operation for cutting open the skin at plant C was hygienically superior to the equivalent operation at plant B, but that the operations for skinning the rump and flank at plant B were hygienically superior to the equivalent operations at plant C. The findings suggest that objective assessment of the microbiological effects on carcasses of beef carcass dressing processes will be required to ensure that Hazard Analysis: Critical Control Point and Quality Management Systems are operated to control the microbiological condition of carcasses.

  17. GeoLab's First Field Trials, 2010 Desert RATS: Evaluating Tools for Early Sample Characterization

    NASA Technical Reports Server (NTRS)

    Evans, Cindy A.; Bell, M. S.; Calaway, M. J.; Graff, Trevor; Young, Kelsey

    2011-01-01

    As part of an accelerated prototyping project to support science operations tests for future exploration missions, we designed and built a geological laboratory, GeoLab, that was integrated into NASA's first generation Habitat Demonstration Unit-1/Pressurized Excursion Module (HDU1-PEM). GeoLab includes a pressurized glovebox for transferring and handling samples collected on geological traverses, and a suite of instruments for collecting preliminary data to help characterize those samples. The GeoLab and the HDU1-PEM were tested for the first time as part of the 2010 Desert Research and Technology Studies (DRATS), NASA's analog field exercise for testing mission technologies. The HDU1- PEM and GeoLab participated in two weeks of joint operations in northern Arizona with two crewed rovers and the DRATS science team.

  18. GIS-based smartphone application to support water quality data collection

    USDA-ARS?s Scientific Manuscript database

    Thorough registration of locations, conditions, and operations at sampling sites is essential for any field survey work. The collected information of this type has to be systematic, transferable, and accessible from different locations of data analysis. The handheld data-recording with smart devices...

  19. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR USE OF AN ACTIVE SAMPLING DEVICE FOR THE COLLECTION OF AIRBORNE VOCS AT FIXED INDOOR AND OUTDOOR SITES (UA-F-11.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the methods used to collect indoor and outdoor air samples for the determination of selected volatile organic compounds (VOC's) using a pump to draw air through a Carbotrap Sampler. Volatile organic compounds (VOCs) present in the air are p...

  20. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR STORAGE AND SHIPPING OF SAMPLES (G05)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for storage and shipping of samples. For the NHEXAS project, Harvard School of Public Health/Emory University will collect many different kinds of samples, some of which will require particularly careful storage and shipping ...

  1. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF FIXED SITE INDOOR AND OUTDOOR AIR SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.12)

    EPA Science Inventory

    This SOP describes the procedures to set up, calibrate, initiate and terminate air sampling for persistent organic pollutants. This method is used to sample air, indoors and outdoors, at homes and at day care centers over a 48-hr period.

  2. Water-quality data from ground- and surface-water sites near concentrated animal feeding operations (CAFOs) and non-CAFOs in the Shenandoah Valley and eastern shore of Virginia, January-February, 2004

    USGS Publications Warehouse

    Rice, Karen C.; Monti, Michele M.; Ettinger, Matthew R.

    2005-01-01

    Concentrated animal feeding operations (CAFOs) result from the consolidation of small farms with animals into larger operations, leading to a higher density of animals per unit of land on CAFOs than on small farms. The density of animals and subsequent concentration of animal wastes potentially can cause contamination of nearby ground and surface waters. This report summarizes water-quality data collected from agricultural sites in the Shenandoah Valley and Eastern Shore of Virginia. Five sites, three non-CAFO and two dairy-operation CAFO sites, were sampled in the Shenandoah Valley. Four sites, one non-CAFO and three poultry-operation CAFO sites were sampled on the Eastern Shore. All samples were collected during January and February 2004. Water samples were analyzed for the following parameters and constituents: temperature, specific conductance, pH, and dissolved oxygen; concentrations of the indicator organisms Escherichia coli (E. coli) and enterococci; bacterial isolates of E. coli, enterococci, Salmonella spp., and Campylobacter spp.; sensitivity to antibiotics of E. coli, enterococci, and Salmonella spp.; arsenic, cadmium, chromium3+, copper, nickel, and mercury; hardness, biological oxygen demand, nitrate, nitrite, ammonia, ortho-phosphate, total Kjeldahl nitrogen, chemical oxygen demand, total organic carbon, and dissolved organic carbon; and 45 dissolved organic compounds, which included a suite of antibiotic compounds.Data are presented in tables 5-21 and results of analyses of replicate samples are presented in tables 22-28. A summary of the data in tables 5-8 and 18-21 is included in the report.

  3. In vivo testing for gold nanoparticle toxicity.

    PubMed

    Simpson, Carrie A; Huffman, Brian J; Cliffel, David E

    2013-01-01

    A technique for measuring the toxicity of nanomaterials using a murine model is described. Blood samples are collected via submandibular bleeding while urine samples are collected on cellophane sheets. Both biosamples are then analyzed by inductively coupled plasma optical emission spectroscopy (ICP-OES) for nanotoxicity. Blood samples are further tested for immunological response using a standard Coulter counter. The major organs of interest for filtration are also digested and analyzed via ICP-OES, producing useful information regarding target specificity of the nanomaterial of interest. Collection of the biosamples and analysis afterward is detailed, and the operation of the technique is described and illustrated by analysis of the nanotoxicity of an injection of a modified tiopronin monolayer-protected cluster.

  4. US EPA BASE Study Standard Operating Procedure for Sampling of Particulates

    EPA Pesticide Factsheets

    The objective of the procedure described is to collect a sample of particles of respirable and inhalable size (approx. 0.1 to 10 microns in diameter) from indoor air and from the outdoor air supplied to the indoor space tested.

  5. Post-Closure Monitoring Report for Corrective Action Unit 339: Area 12 Fleet Operations Steam Cleaning Effluent Nevada Test Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    K. B. Campbell

    2002-09-01

    The Area 12 Fleet Operations Steam Cleaning Effluent site is located in the southeastern portion of the Area 12 Camp at the Nevada Test Site. This site is identified in the Federal Facility Agreement and Consent Order (1996) as Corrective Action Site (CAS) 12-19-01 and is the only CAS assigned to Corrective Action Unit (CAU) 339. Post-closure sampling and inspection of the site were completed on March 27, 2002. Post-closure monitoring activities were scheduled biennially (every two years) in the Post-Closure Monitoring Plan provided in the Closure Report for CAU 339: Area 12 Fleet Operations Steam Cleaning Effluent, Nevada Testmore » Site (U.S. Department of Energy, Nevada Operations Office [DOEN], 1997). A baseline for the site was established by sampling in 1997. Based on the recommendations from the 1999 post-closure monitoring report (DOE/NV, 1999), samples were collected in 2000, earlier than originally proposed, because the 1999 sample results did not provide the expected decrease in total petroleum hydrocarbon (TPH) concentrations at the site. Sampling results from 2000 (DOE/NV, 2000) and 2001 (DOE/NV, 2001) revealed favorable conditions for natural degradation at the CAU 339 site, but because of differing sample methods and heterogeneity of the soil, data results from 2000 and later were not directly correlated with previous results. Post-closure monitoring activities for 2002 consisted of the following: (1) Soil sample collection from three undisturbed plots (Plots A, B, and C, Figure 2). (2) Sample analysis for TPH as oil and bio-characterization parameters (Comparative Enumeration Assay [CEA] and Standard Nutrient Panel [SNP]). (3) Site inspection to evaluate the condition of the fencing and signs. (4) Preparation and submittal of the Post-Closure Monitoring Report.« less

  6. The precision of wet atmospheric deposition data from national atmospheric deposition program/national trends network sites determined with collocated samplers

    USGS Publications Warehouse

    Nilles, M.A.; Gordon, J.D.; Schroder, L.J.

    1994-01-01

    A collocated, wet-deposition sampler program has been operated since October 1988 by the U.S. Geological Survey to estimate the overall sampling precision of wet atmospheric deposition data collected at selected sites in the National Atmospheric Deposition Program and National Trends Network (NADP/NTN). A duplicate set of wet-deposition sampling instruments was installed adjacent to existing sampling instruments at four different NADP/NTN sites for each year of the study. Wet-deposition samples from collocated sites were collected and analysed using standard NADP/NTN procedures. Laboratory analyses included determinations of pH, specific conductance, and concentrations of major cations and anions. The estimates of precision included all variability in the data-collection system, from the point of sample collection through storage in the NADP/NTN database. Sampling precision was determined from the absolute value of differences in the analytical results for the paired samples in terms of median relative and absolute difference. The median relative difference for Mg2+, Na+, K+ and NH4+ concentration and deposition was quite variable between sites and exceeded 10% at most sites. Relative error for analytes whose concentrations typically approached laboratory method detection limits were greater than for analytes that did not typically approach detection limits. The median relative difference for SO42- and NO3- concentration, specific conductance, and sample volume at all sites was less than 7%. Precision for H+ concentration and deposition ranged from less than 10% at sites with typically high levels of H+ concentration to greater than 30% at sites with low H+ concentration. Median difference for analyte concentration and deposition was typically 1.5-2-times greater for samples collected during the winter than during other seasons at two northern sites. Likewise, the median relative difference in sample volume for winter samples was more than double the annual median relative difference at the two northern sites. Bias accounted for less than 25% of the collocated variability in analyte concentration and deposition from weekly collocated precipitation samples at most sites.A collocated, wet-deposition sampler program has been operated since OCtober 1988 by the U.S Geological Survey to estimate the overall sampling precision of wet atmospheric deposition data collected at selected sites in the National Atmospheric Deposition Program and National Trends Network (NADP/NTN). A duplicate set of wet-deposition sampling instruments was installed adjacent to existing sampling instruments four different NADP/NTN sites for each year of the study. Wet-deposition samples from collocated sites were collected and analysed using standard NADP/NTN procedures. Laboratory analyses included determinations of pH, specific conductance, and concentrations of major cations and anions. The estimates of precision included all variability in the data-collection system, from the point of sample collection through storage in the NADP/NTN database.

  7. System for sampling and monitoring microscopic organisms and substances

    DOEpatents

    Au, Frederick H. F.; Beckert, Werner F.

    1976-01-01

    A technique and apparatus used therewith for determining the uptake of plutonium and other contaminants by soil microorganisms which, in turn, gives a measure of the plutonium and/or other contaminants available to the biosphere at that particular time. A measured quantity of uncontaminated spores of a selected mold is added to a moistened sample of the soil to be tested. The mixture is allowed to sit a predetermined number of days under specified temperature conditions. An agar layer is then applied to the top of the sample. After three or more days, when spores of the mold growing in the sample have formed, the spores are collected by a miniature vacuum collection apparatus operated under preselected vacuum conditions, which collect only the spores with essentially no contamination by mycelial fragments or culture medium. After collection, the fungal spores are dried and analyzed for the plutonium and/or other contaminants. The apparatus is also suitable for collection of pollen, small insects, dust and other small particles, material from thin-layer chromatography plates, etc.

  8. Evaluation of factors that affect diesel exhaust toxicity. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Norbeck, J.M.; Smith, M.R.; Arey, J.

    1998-07-01

    The scope of this project was to obtain a preliminary assessment of the potential impact of the fuel formulation on the speciation and toxic components of diesel exhaust. The test bed was a Cummins L10 engine operating over the heavy-duty transient test cycle using three diesel fuels: a pre-1993 diesel fuel, a low aromatic diesel fuel, and an alternative formulation diesel fuel. The sampling/analysis plan included: determination of the criteria pollutant emission rates (THC, CO, NOx, and PM); determination of PM(10) and PM(2.5) emission rates; collection and analysis of particulate samples for elemental, inorganic ion and elemental/organic carbon analyses; collectionmore » of bas samples for VOC speciation analyses; collection of 2,4-dinitrophenylhydrazine (DNPH) cartridges for determination of oxygenates; collection of nitrosomorpholine with Thermosorb N cartridges; collection of semi-volatiles on PF/XAD and particulate samples for PAH, nitro-PAH, and mutagenicity studies; and collection and analysis of dioxins for the pre-1993 and alternative formulation diesel fuels.« less

  9. The influence of baking fuel on residues of polycyclic aromatic hydrocarbons and heavy metals in bread.

    PubMed

    Ahmed, M T; Abdel Hadi el-S; el-Samahy, S; Youssof, K

    2000-12-30

    The influence of fuel type used to bake bread on the spectrum and concentrations of some polycyclic aromatic hydrocarbons and heavy metals in baked bread was assessed. Bread samples were collected from different bakeries operated by either electricity, solar, mazot or solid waste and their residue content of PAHs and heavy metals was assessed. The total concentration of PAHs detected in mazot, solar, solid waste and electricity operated bakeries had an average of 320.6, 158.4, 317.3 and 25.5 microgkg(-1), respectively. Samples collected from mazot, solar and solid waste operated bakeries have had a wide spectrum of PAHs, in comparison to that detected in bread samples collected from electricity operated bakeries. Lead had the highest concentrations in the four groups of bread samples, followed by nickel, while the concentrations of zinc and cadmium were the least. The concentration of lead detected in bread samples produced from mazot, solar, solid waste and electricity fueled bakeries were 1375.5, 1114, 1234, and 257.3 microgkg(-1), respectively. Estimated daily intake of PAHs based on bread consumption were 48.2, 28.5, 80. 1, and 4.8 microg per person per day for bread produced in bakeries using mazot, solar, solid waste and electricity, respectively. Meanwhile, the estimated daily intake of benzo (a) pyrene were 3.69, 2.65, 8.1, and 0.81 microg per person per day for bread sample baked with mazot, solar, solid waste and electricity, respectively. The daily intake of lead, based on bread consumption was 291, 200.5, 222, and 46.31 microg per person per day for bread sample baked with mazot, solar, solid waste and electricity, respectively. The present work has indicated the comparatively high level of daily intake of benzo (a) pyrene and lead in comparison to levels reported from many other countries and those recommended by international regulatory bodies. It is probable that residues detected in bread samples are partially cereal-borne but there is strong evidence that the process of baking and the gases emitted are responsible for most of the contamination load.

  10. Onsite Gaseous Centrifuge Enrichment Plant UF6 Cylinder Destructive Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anheier, Norman C.; Cannon, Bret D.; Qiao, Hong

    2012-07-17

    The IAEA safeguards approach for gaseous centrifuge enrichment plants (GCEPs) includes measurements of gross, partial, and bias defects in a statistical sampling plan. These safeguard methods consist principally of mass and enrichment nondestructive assay (NDA) verification. Destructive assay (DA) samples are collected from a limited number of cylinders for high precision offsite mass spectrometer analysis. DA is typically used to quantify bias defects in the GCEP material balance. Under current safeguards measures, the operator collects a DA sample from a sample tap following homogenization. The sample is collected in a small UF6 sample bottle, then sealed and shipped under IAEAmore » chain of custody to an offsite analytical laboratory. Current practice is expensive and resource intensive. We propose a new and novel approach for performing onsite gaseous UF6 DA analysis that provides rapid and accurate assessment of enrichment bias defects. DA samples are collected using a custom sampling device attached to a conventional sample tap. A few micrograms of gaseous UF6 is chemically adsorbed onto a sampling coupon in a matter of minutes. The collected DA sample is then analyzed onsite using Laser Ablation Absorption Ratio Spectrometry-Destructive Assay (LAARS-DA). DA results are determined in a matter of minutes at sufficient accuracy to support reliable bias defect conclusions, while greatly reducing DA sample volume, analysis time, and cost.« less

  11. The NASA Ames Life Sciences Data Archive: Biobanking for the Final Frontier

    NASA Technical Reports Server (NTRS)

    Rask, Jon; Chakravarty, Kaushik; French, Alison J.; Choi, Sungshin; Stewart, Helen J.

    2017-01-01

    The NASA Ames Institutional Scientific Collection involves the Ames Life Sciences Data Archive (ALSDA) and a biospecimen repository, which are responsible for archiving information and non-human biospecimens collected from spaceflight and matching ground control experiments. The ALSDA also manages a biospecimen sharing program, performs curation and long-term storage operations, and facilitates distribution of biospecimens for research purposes via a public website (https:lsda.jsc.nasa.gov). As part of our best practices, a tissue viability testing plan has been developed for the repository, which will assess the quality of samples subjected to long-term storage. We expect that the test results will confirm usability of the samples, enable broader science community interest, and verify operational efficiency of the archives. This work will also support NASA open science initiatives and guides development of NASA directives and policy for curation of biological collections.

  12. Measurement of polynuclear aromatic hydrocarbons (PAHs) in epiphytic lichens and from PM 2.5 filters for receptor modeling in the Alberta Oil Sands Region (Invited)

    NASA Astrophysics Data System (ADS)

    Studabaker, W. B.; Jayanty, J.; Raymer, J. H.; Krupa, S.

    2013-12-01

    As mining and refinery operations in the Alberta Oil Sands Region (AOSR) have expanded, there has been increasing concern for the impacts of air pollution generated by those operations on both human and ecosystem health. The inaccessibility of much of the AOSR makes it difficult to establish conventional air quality monitoring stations to the extent needed to model long-range impacts of emissions from the AOSR operations. Epiphytic lichens are important markers of ecosystem health, are well-established bioaccumulators of trace metals, and are potentially useful biomonitors of air pollution. However, their ability to take up organic pollutants has not been extensively explored, and only recently have they been used for biomonitoring of pollution by PAHs. Here we describe the determination of polynuclear aromatic hydrocarbons (PAHs) in lichens, collected from sites throughout the AOSR, for modeling emissions associated with mining and oil extraction operations. We also describe preliminary results of the determination of PAHs in PM 2.5 filters from dichotomous samplers stationed in the AOSR, in the context of the biological sample data. Lichens (Hypogymnia physodes) were collected on two separate occasions. During the summer of 2009, single samples were taken from 200 sites in the AOSR; a subset of 20 of these was selected for determination of PAHs. During the summer of 2011, triplicate samples (from separate trees within a site) were collected from 20 sites representing similar locations to the 2008 sites. Lichens were milled in a cryogenic impactor, then were extracted with cyclohexane. Extracts were purified on silica gel using automated solid phase extraction and analyzed by gas chromatography with mass selective detection. Method detection limits for individual PAHs were 2-4 ng/g. Total PAHs in the samples from both collection events ranged from 50 ng/g to 350 ng/g, and declined with increasing distance from the mining and refinery operations. The relative contribution of low ring number PAHs to total PAHs increased with increasing distance. Total PAHs correlated strongly (R2 > 0.80, p < 0.05) with crustal elements, suggesting similar transport mechanisms. Analytical data for PAHs on PM 2.5 filters, including relationships between concentrations, PAH profiles, and distance from the mines, will be presented. The lichen data are consistent with PAH transport close to the mines being more influenced by particulate matter transport mechanisms, whereas PAHs in samples collected from remote areas reflect more of the vapor phase transport mechanisms.

  13. Development and field application of a 6-bottle serial gas-tight fluid sampler for collecting seafloor cold seep and hydrothermal vent fluids with autonomous operation capability

    NASA Astrophysics Data System (ADS)

    Wu, S.; Ding, K.; Yang, C.; Seyfried, W. E., Jr.; Tan, C.; Schaen, A. T.; Luhmann, A. J.

    2014-12-01

    A 6-bottle serial gas-tight sampler (so-called "six-shooter") was developed for application with deep-sea vent fluids. The new device is composed of a custom-made 6-channel valve manifold and six sampling bottles which are circularly distributed around the valve manifold. Each valve channel consists of a high-pressure titanium cartridge valve and a motor-driven actuator. A sampling snorkel is connected to the inlet of the manifold that delivers the incoming fluid to different bottles. Each sampling bottle has a 160 ml-volume chamber and an accumulator chamber inside where compressed nitrogen is used to maintain the sample at near in-situ pressure. An electronics chamber that is located at the center of the sampler is used to carry out all sampling operations, autonomously, if desired. The sampler is of a compact circular configuration with a diameter of 26 cm and a length of 54 cm. During the SVC cruise AT 26-12, the sampler was deployed by DSV2 Alvin at a cold seep site MC036 with a depth of 1090 m in the Gulf of Mexico. The sampler collected fluid samples automatically following the tidal cycle to monitor the potential impact of the tide cycle on the fluid chemistry of cold seep in a period of two day. During the cruise AT 26-17, the sampler was used with newly upgraded DSV2 Alvin three times at the hydrothermal vent sites along Axial Seamount and Main Endeavor Field on Juan de Fuca Ridge. During a 4-day deployment at Anemone diffuse site (Axial Caldera), the sampler was set to work in an autonomous mode to collect fluid samples according to the preset interval. During other dives, the sampler was manually controlled via ICL (Inductively Coupled Link) communication through the hull. Gas-tight fluid samples were collected from different hydrothermal vents with temperatures between 267 ℃ and 335 ℃ at the depth up to 2200 m. The field results indicate unique advantages of the design. It can be deployed in extended time period with remote operation or working autonomously taking gas-tight fluid samples. If used with HOV or ROV, it will reduce basket space occupation and ICL communication cables compared to traditional single-bottle gas-tight samplers. This time serial gas-tight fluid sampler will be further developed into a 36 bottle system for remote operation with seafloor cabled observatory.

  14. Characterization of nutrients and fecal indicator bacteria at a concentrated swine feeding operation in Wake County, North Carolina, 2009-2011

    USGS Publications Warehouse

    Harden, Stephen L.; Rogers, Shane W.; Jahne, Michael A.; Shaffer, Carrie E.; Smith, Douglas G.

    2012-01-01

    Study sites were sampled for laboratory analysis of nutrients, total suspended solids (TSS), and (or) fecal indicator bacteria (FIB). Nutrient analyses included measurement of dissolved ammonia, total and dissolved ammonia + organic nitrogen, dissolved nitrate + nitrite, dissolved orthophosphate, and total phosphorus. The FIB analyses included measurement of Escherichia coli and enterococci. Samples of wastewater at the swine facility were collected from a pipe outfall from the swine housing units, two storage lagoons, and the spray fields for analysis of nutrients, TSS, and FIB. Soil samples collected from a spray field were analyzed for FIB. Monitoring locations were established for collecting discharge and water-quality data during storm events at three in-field runoff sites and two sites on the headwater stream (one upstream and one downstream) next to the swine facility. Stormflow samples at the five monitoring locations were collected for four storm events during 2009 to 2010 and analyzed for nutrients, TSS, and FIB. Monthly water samples also were collected during base-flow conditions at all four stream sites for laboratory analysis of nutrients, TSS, and (or) FIB.

  15. FTA card utility for PCR detection of Mycobacterium leprae.

    PubMed

    Aye, Khin Saw; Matsuoka, Masanori; Kai, Masanori; Kyaw, Kyaw; Win, Aye Aye; Shwe, Mu Mu; Thein, Min; Htoo, Maung Maung; Htoon, Myo Thet

    2011-01-01

    The suitability of the FTA® elute card for the collection of slit skin smear (SSS) samples for PCR detection of Mycobacterium leprae was evaluated. A total of 192 SSS leprosy samples, of bacillary index (BI) 1 to 5, were collected from patients attending two skin clinics in Myanmar and preserved using both FTA® elute cards and 70% ethanol tubes. To compare the efficacy of PCR detection of DNA from each BI class, PCR was performed to amplify an M. leprae-specific repetitive element. Of the 192 samples, 116 FTA® elute card and 112 70% ethanol samples were PCR positive for M. leprae DNA. When correlated with BI, area under the curve (AUC) values of the respective receiver-operating characteristic curves were similar for the FTA® elute card and ethanol collection methods (AUC=0.6). Taken together, our results indicate that the FTA® elute card, which enables the collection, transport, and archiving of clinical samples, is an attractive alternative to ethanol preservation for the detection of M. leprae DNA.

  16. Summary of inorganic compositional data for groundwater, soil-water, and surface-water samples collected at the Headgate Draw subsurface drip irrigation site, Johnson County, Wyoming

    USGS Publications Warehouse

    Geboy, Nicholas J.; Engle, Mark A.; Schroeder, Karl T.; Zupancic, John W.

    2011-01-01

    As part of a 5-year project on the impact of subsurface drip irrigation (SDI) application of coalbed-methane (CBM) produced waters, water samples were collected from the Headgate Draw SDI site in the Powder River Basin, Wyoming, USA. This research is part of a larger study to understand short- and long-term impacts on both soil and water quality from the beneficial use of CBM waters to grow forage crops through use of SDI. This document provides a summary of the context, sampling methodology, and quality assurance and quality control documentation of samples collected prior to and over the first year of SDI operation at the site (May 2008-October 2009). This report contains an associated database containing inorganic compositional data, water-quality criteria parameters, and calculated geochemical parameters for samples of groundwater, soil water, surface water, treated CBM waters, and as-received CBM waters collected at the Headgate Draw SDI site.

  17. A rapid method for the sampling of atmospheric water vapour for isotopic analysis.

    PubMed

    Peters, Leon I; Yakir, Dan

    2010-01-01

    Analysis of the stable isotopic composition of atmospheric moisture is widely applied in the environmental sciences. Traditional methods for obtaining isotopic compositional data from ambient moisture have required complicated sampling procedures, expensive and sophisticated distillation lines, hazardous consumables, and lengthy treatments prior to analysis. Newer laser-based techniques are expensive and usually not suitable for large-scale field campaigns, especially in cases where access to mains power is not feasible or high spatial coverage is required. Here we outline the construction and usage of a novel vapour-sampling system based on a battery-operated Stirling cycle cooler, which is simple to operate, does not require any consumables, or post-collection distillation, and is light-weight and highly portable. We demonstrate the ability of this system to reproduce delta(18)O isotopic compositions of ambient water vapour, with samples taken simultaneously by a traditional cryogenic collection technique. Samples were collected over 1 h directly into autosampler vials and were analysed by mass spectrometry after pyrolysis of 1 microL aliquots to CO. This yielded an average error of < +/-0.5 per thousand, approximately equal to the signal-to-noise ratio of traditional approaches. This new system provides a rapid and reliable alternative to conventional cryogenic techniques, particularly in cases requiring high sample throughput or where access to distillation lines, slurry maintenance or mains power is not feasible. Copyright 2009 John Wiley & Sons, Ltd.

  18. Sampling and monitoring for closure

    USGS Publications Warehouse

    McLemore, Virginia T.; Smith, Kathleen S.; Russell, Carol C.

    2007-01-01

    An important aspect of planning a new mine or mine expansion within the modern regulatory framework is to design for ultimate closure. Sampling and monitoring for closure is a form of environmental risk management. By implementing a sampling and monitoring program early in the life of the mining operation, major costs can be avoided or minimized. The costs for treating mine drainage in perpetuity are staggering, especially if they are unanticipated. The Metal Mining Sector of the Acid Drainage Technology Initiative (ADTI-MMS), a cooperative government-industry-academia organization, was established to address drainage-quality technologies of metal mining and metallurgical operations. ADTI-MMS recommends that sampling and monitoring programs consider the entire mine-life cycle and that data needed for closure of an operation be collected from exploration through postclosure.

  19. Annual radiological environmental operating report, Browns Ferry Nuclear Plant, 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-04-01

    This report describes the environmental radiological monitoring program conducted by TVA in the vicinity of Browns Ferry Nuclear Plant in 1991. The program includes the collection of samples from the environment and the determination of the concentrations of radioactive materials in the samples. Samples are taken from stations in the general area of the plant and from areas not influenced by plant operations. Station locations are selected after careful consideration of the weather patterns and projected radiation doses to the various areas around the plant. Material sampled includes air, water, milk, foods, vegetation, soil, fish, sediment, and direct radiation levels.more » Results from stations near the plant are compared with concentrations from control stations and with preoperational measurements to determine potential impacts of plant operations.« less

  20. The incidence and role of drugs in fatally injured drivers

    DOT National Transportation Integrated Search

    1992-10-30

    Blood specimens were collected from a sample of 1882 drivers from 7 States, during 14 months in the years 1990 and 1991. The sample comprised operators of passenger cars, trucks, and motorcycles who died within 4 hours of their crash. Alcohol and 43 ...

  1. NHEXAS PHASE I MARYLAND STUDY--LIST OF AVAILABLE DOCUMENTS: PROTOCOLS AND SOPS

    EPA Science Inventory

    This document lists available protocols and SOPs for the NHEXAS Phase I Maryland study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis and general laboratory procedures, (3) Data Analysis Proced...

  2. Annual radiological environmental operating report: Browns Ferry Nuclear Plant, 1992. Operations Services/Technical Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-04-01

    This report describes the environmental radiological monitoring program conducted by TVA in the vicinity of Browns Ferry Nuclear Plant (BFN) in 1992. The program includes the collection of samples from the environment and the determination of the concentrations of radioactive materials in the samples. Samples are taken from stations in the general area of the plant and from areas not influenced by plant operations. Station locations are selected after careful consideration of the weather patterns and projected radiation doses to the various areas around the plant. Material sampled includes air, water, milk, foods, vegetation, soil, fish, sediment, and direct radiationmore » levels. Results from stations near the plant are compared with concentrations from control stations and with preoperational measurements to determine potential impacts of plant operations. Small amounts of Co-60 and Cs-134 were found in sediment samples downstream from the plant. This activity in stream sediment would result in no measurable increase over background in the dose to the general public.« less

  3. Space X First Entry Sample Analysis

    NASA Technical Reports Server (NTRS)

    James, John T.

    2012-01-01

    The toxicological assessment of one sample collected on May 26, 2012 and returned to earth on May 31, 2012 was analyzed for pollutants that had offgassed into the Dragon capsule by the time of first entry operations performed by the ISS crew. The components identified in the first-entry sample and their contributions to the total T-value are shown.

  4. An automated atmospheric sampling system operating on 747 airliners

    NASA Technical Reports Server (NTRS)

    Perkins, P. J.; Gustafsson, U. R. C.

    1976-01-01

    An air sampling system that automatically measures the temporal and spatial distribution of particulate and gaseous constituents of the atmosphere is collecting data on commercial air routes covering the world. Measurements are made in the upper troposphere and lower stratosphere (6 to 12 km) of constituents related to aircraft engine emissions and other pollutants. Aircraft operated by different airlines sample air at latitudes from the Arctic to Australia. This unique system includes specialized instrumentation, a special air inlet probe for sampling outside air, a computerized automatic control, and a data acquisition system. Air constituent and related flight data are tape recorded in flight for later computer processing on the ground.

  5. Evaluation of standardized sample collection, packaging, and decontamination procedures to assess cross-contamination potential during Bacillus anthracis incident response operations

    PubMed Central

    Calfee, M. Worth; Tufts, Jenia; Meyer, Kathryn; McConkey, Katrina; Mickelsen, Leroy; Rose, Laura; Dowell, Chad; Delaney, Lisa; Weber, Angela; Morse, Stephen; Chaitram, Jasmine; Gray, Marshall

    2016-01-01

    Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures. Both decontamination procedures were quantitatively evaluated on three types of sample packaging materials (corrugated fiberboard, polystyrene foam, and polyethylene plastic), and two contamination mechanisms (wet or dry inoculums). Contaminant transfer results suggested that size-appropriate gloves should be worn by personnel, templates should not be taped to or removed from surfaces, and primary receptacles should be selected carefully. The decontamination tests indicated that wipe-based decontamination procedures may be more effective than spray-based procedures; efficacy was not influenced by material type but was affected by the inoculation method. Incomplete surface decontamination was observed in all tests with dry inoculums. This study provides a foundation for optimizing current B. anthracis response procedures to minimize contaminant exfiltration. PMID:27362274

  6. Evaluation of standardized sample collection, packaging, and decontamination procedures to assess cross-contamination potential during Bacillus anthracis incident response operations.

    PubMed

    Calfee, M Worth; Tufts, Jenia; Meyer, Kathryn; McConkey, Katrina; Mickelsen, Leroy; Rose, Laura; Dowell, Chad; Delaney, Lisa; Weber, Angela; Morse, Stephen; Chaitram, Jasmine; Gray, Marshall

    2016-12-01

    Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures. Both decontamination procedures were quantitatively evaluated on three types of sample packaging materials (corrugated fiberboard, polystyrene foam, and polyethylene plastic), and two contamination mechanisms (wet or dry inoculums). Contaminant transfer results suggested that size-appropriate gloves should be worn by personnel, templates should not be taped to or removed from surfaces, and primary receptacles should be selected carefully. The decontamination tests indicated that wipe-based decontamination procedures may be more effective than spray-based procedures; efficacy was not influenced by material type but was affected by the inoculation method. Incomplete surface decontamination was observed in all tests with dry inoculums. This study provides a foundation for optimizing current B. anthracis response procedures to minimize contaminant exfiltration.

  7. Variable percentage sampler

    DOEpatents

    Miller, Jr., William H.

    1976-01-01

    A remotely operable sampler is provided for obtaining variable percentage samples of nuclear fuel particles and the like for analyses. The sampler has a rotating cup for a sample collection chamber designed so that the effective size of the sample inlet opening to the cup varies with rotational speed. Samples of a desired size are withdrawn from a flowing stream of particles without a deterrent to the flow of remaining particles.

  8. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR ANALYSIS OF SOIL OR HOUSE DUST SAMPLES USING CHLORPYRIFOS ELISA SAMPLES (BCO-L-1.0)

    EPA Science Inventory

    This abstract is included for completeness of documentation, but this SOP was not used in the study.

    The purpose of this SOP is to describe the procedures for analyzing both Stage II and Stage III soil and vacuum-cleaner collected house dust samples, and Stage III air samples u...

  9. The NASA Ames Research Center Institutional Scientific Collection: History, Best Practices and Scientific Opportunities

    NASA Technical Reports Server (NTRS)

    Rask, Jon C.; Chakravarty, Kaushik; French, Alison; Choi, Sungshin; Stewart, Helen

    2017-01-01

    The NASA Ames Life Sciences Institutional Scientific Collection (ISC), which is composed of the Ames Life Sciences Data Archive (ALSDA) and the Biospecimen Storage Facility (BSF), is managed by the Space Biosciences Division and has been operational since 1993. The ALSDA is responsible for archiving information and animal biospecimens collected from life science spaceflight experiments and matching ground control experiments. Both fixed and frozen spaceflight and ground tissues are stored in the BSF within the ISC. The ALSDA also manages a Biospecimen Sharing Program, performs curation and long-term storage operations, and makes biospecimens available to the scientific community for research purposes via the Life Science Data Archive public website (https:lsda.jsc.nasa.gov). As part of our best practices, a viability testing plan has been developed for the ISC, which will assess the quality of archived samples. We expect that results from the viability testing will catalyze sample use, enable broader science community interest, and improve operational efficiency of the ISC. The current viability test plan focuses on generating disposition recommendations and is based on using ribonucleic acid (RNA) integrity number (RIN) scores as a criteria for measurement of biospecimen viablity for downstream functional analysis. The plan includes (1) sorting and identification of candidate samples, (2) conducting a statiscally-based power analysis to generate representaive cohorts from the population of stored biospecimens, (3) completion of RIN analysis on select samples, and (4) development of disposition recommendations based on the RIN scores. Results of this work will also support NASA open science initiatives and guides development of the NASA Scientific Collections Directive (a policy on best practices for curation of biological collections). Our RIN-based methodology for characterizing the quality of tissues stored in the ISC since the 1980s also creates unique scientific opportunities for temporal assessment across historical missions. Support from the NASA Space Biology Program and the NASA Human Research Program is gratefully acknowledged.

  10. OSIRIS-REx Touch-and-Go (TAG) Mission Design for Asteroid Sample Collection

    NASA Technical Reports Server (NTRS)

    May, Alexander; Sutter, Brian; Linn, Timothy; Bierhaus, Beau; Berry, Kevin; Mink, Ron

    2014-01-01

    The Origins Spectral Interpretation Resource Identification Security Regolith Explorer (OSIRIS-REx) mission is a NASA New Frontiers mission launching in September 2016 to rendezvous with the near-Earth asteroid Bennu in October 2018. After several months of proximity operations to characterize the asteroid, OSIRIS-REx flies a Touch-And-Go (TAG) trajectory to the asteroid's surface to collect at least 60 g of pristine regolith sample for Earth return. This paper provides mission and flight system overviews, with more details on the TAG mission design and key events that occur to safely and successfully collect the sample. An overview of the navigation performed relative to a chosen sample site, along with the maneuvers to reach the desired site is described. Safety monitoring during descent is performed with onboard sensors providing an option to abort, troubleshoot, and try again if necessary. Sample collection occurs using a collection device at the end of an articulating robotic arm during a brief five second contact period, while a constant force spring mechanism in the arm assists to rebound the spacecraft away from the surface. Finally, the sample is measured quantitatively utilizing the law of conservation of angular momentum, along with qualitative data from imagery of the sampling device. Upon sample mass verification, the arm places the sample into the Stardust-heritage Sample Return Capsule (SRC) for return to Earth in September 2023.

  11. Integrated fiducial sample mount and software for correlated microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Timothy R McJunkin; Jill R. Scott; Tammy L. Trowbridge

    2014-02-01

    A novel design sample mount with integrated fiducials and software for assisting operators in easily and efficiently locating points of interest established in previous analytical sessions is described. The sample holder and software were evaluated with experiments to demonstrate the utility and ease of finding the same points of interest in two different microscopy instruments. Also, numerical analysis of expected errors in determining the same position with errors unbiased by a human operator was performed. Based on the results, issues related to acquiring reproducibility and best practices for using the sample mount and software were identified. Overall, the sample mountmore » methodology allows data to be efficiently and easily collected on different instruments for the same sample location.« less

  12. US EPA Base Study Standard Operating Procedure for Sampling Volatile Organic Compounds in Indoor Air using Multisorbent Samplers

    EPA Pesticide Factsheets

    The objective of this procedure is to collect representative samples of volatile organic compound (VOC) contaminants present in indoor and outdoor environments using multisorbent samplers, and to subsequently analyze the concentration of VOCs, as selected by EPA.

  13. 30 CFR 36.43 - Determination of exhaust-gas composition.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... of fuel consumption, pressures, temperatures, and other data significant in the safe operation of diesel equipment. (b) Exhaust-gas samples shall be analyzed for carbon dioxide, oxygen, carbon monoxide....45). The engine shall be at temperature equilibrium before exhaust-gas samples are collected or other...

  14. 30 CFR 36.43 - Determination of exhaust-gas composition.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... of fuel consumption, pressures, temperatures, and other data significant in the safe operation of diesel equipment. (b) Exhaust-gas samples shall be analyzed for carbon dioxide, oxygen, carbon monoxide....45). The engine shall be at temperature equilibrium before exhaust-gas samples are collected or other...

  15. 30 CFR 36.43 - Determination of exhaust-gas composition.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... of fuel consumption, pressures, temperatures, and other data significant in the safe operation of diesel equipment. (b) Exhaust-gas samples shall be analyzed for carbon dioxide, oxygen, carbon monoxide....45). The engine shall be at temperature equilibrium before exhaust-gas samples are collected or other...

  16. 30 CFR 36.43 - Determination of exhaust-gas composition.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... of fuel consumption, pressures, temperatures, and other data significant in the safe operation of diesel equipment. (b) Exhaust-gas samples shall be analyzed for carbon dioxide, oxygen, carbon monoxide....45). The engine shall be at temperature equilibrium before exhaust-gas samples are collected or other...

  17. 30 CFR 36.43 - Determination of exhaust-gas composition.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... of fuel consumption, pressures, temperatures, and other data significant in the safe operation of diesel equipment. (b) Exhaust-gas samples shall be analyzed for carbon dioxide, oxygen, carbon monoxide....45). The engine shall be at temperature equilibrium before exhaust-gas samples are collected or other...

  18. Electronic field permeameter

    DOEpatents

    Chandler, Mark A.; Goggin, David J.; Horne, Patrick J.; Kocurek, Gary G.; Lake, Larry W.

    1989-01-01

    For making rapid, non-destructive permeability measurements in the field, a portable minipermeameter of the kind having a manually-operated gas injection tip is provided with a microcomputer system which operates a flow controller to precisely regulate gas flow rate to a test sample, and reads a pressure sensor which senses the pressure across the test sample. The microcomputer system automatically turns on the gas supply at the start of each measurement, senses when a steady-state is reached, collects and records pressure and flow rate data, and shuts off the gas supply immediately after the measurement is completed. Preferably temperature is also sensed to correct for changes in gas viscosity. The microcomputer system may also provide automatic zero-point adjustment, sensor calibration, over-range sensing, and may select controllers, sensors, and set-points for obtaining the most precise measurements. Electronic sensors may provide increased accuracy and precision. Preferably one microcomputer is used for sensing instrument control and data collection, and a second microcomputer is used which is dedicated to recording and processing the data, selecting the sensors and set-points for obtaining the most precise measurements, and instructing the user how to set-up and operate the minipermeameter. To provide mass data collection and user-friendly operation, the second microcomputer is preferably a lap-type portable microcomputer having a non-volatile or battery-backed CMOS memory.

  19. A large volume particulate and water multi-sampler with in situ preservation for microbial and biogeochemical studies

    NASA Astrophysics Data System (ADS)

    Breier, J. A.; Sheik, C. S.; Gomez-Ibanez, D.; Sayre-McCord, R. T.; Sanger, R.; Rauch, C.; Coleman, M.; Bennett, S. A.; Cron, B. R.; Li, M.; German, C. R.; Toner, B. M.; Dick, G. J.

    2014-12-01

    A new tool was developed for large volume sampling to facilitate marine microbiology and biogeochemical studies. It was developed for remotely operated vehicle and hydrocast deployments, and allows for rapid collection of multiple sample types from the water column and dynamic, variable environments such as rising hydrothermal plumes. It was used successfully during a cruise to the hydrothermal vent systems of the Mid-Cayman Rise. The Suspended Particulate Rosette V2 large volume multi-sampling system allows for the collection of 14 sample sets per deployment. Each sample set can include filtered material, whole (unfiltered) water, and filtrate. Suspended particulate can be collected on filters up to 142 mm in diameter and pore sizes down to 0.2 μm. Filtration is typically at flowrates of 2 L min-1. For particulate material, filtered volume is constrained only by sampling time and filter capacity, with all sample volumes recorded by digital flowmeter. The suspended particulate filter holders can be filled with preservative and sealed immediately after sample collection. Up to 2 L of whole water, filtrate, or a combination of the two, can be collected as part of each sample set. The system is constructed of plastics with titanium fasteners and nickel alloy spring loaded seals. There are no ferrous alloys in the sampling system. Individual sample lines are prefilled with filtered, deionized water prior to deployment and remain sealed unless a sample is actively being collected. This system is intended to facilitate studies concerning the relationship between marine microbiology and ocean biogeochemistry.

  20. Method for collecting spores from a mold

    DOEpatents

    Au, Frederick H. F.; Beckert, Werner F.

    1977-01-01

    A technique and apparatus used therewith for determining the uptake of plutonium and other contaminants by soil microorganisms which, in turn, gives a measure of the plutonium and/or other contaminants available to the biosphere at that particular time. A measured quantity of uncontaminated spores of a selected mold is added to a moistened sample of the soil to be tested. The mixture is allowed to sit a predetermined number of days under specified temperature conditions. An agar layer is then applied to the top of the sample. After three or more days, when spores of the mold growing in the sample have formed, the spores are collected by a miniature vacuum collection apparatus operated under preselected vacuum conditions, which collect only the spores with essentially no contamination by mycelial fragments or culture medium. After collection, the fungal spores are dried and analyzed for the plutonium and/or other contaminants. The apparatus is also suitable for collection of pollen, small insects, dust and other small particles, material from thin-layer chromatography plates, etc.

  1. Fishery research in the Great Lakes using a low-cost remotely operated vehicle

    USGS Publications Warehouse

    Kennedy, Gregory W.; Brown, Charles L.; Argyle, Ray L.

    1988-01-01

    We used a MiniROVER MK II remotely operated vehicle (ROV) to collect ground-truth information on fish and their habitat in the Great Lakes that have traditionally been collected by divers, or with static cameras, or submersibles. The ROV, powered by 4 thrusters and controlled by the pilot at the surface, was portable and efficient to operate throughout the Great Lakes in 1987, and collected a total of 30 h of video data recorded for later analysis. We collected 50% more substrate information per unit of effort with the ROV than with static cameras. Fish behavior ranged from no avoidance reaction in ambient light, to erratic responses in the vehicle lights. The ROV's field of view depended on the time of day, light levels, and density of zooplankton. Quantification of the data collected with the ROV (either physical samples or video image data) will serve to enhance the use of the ROV as a research tool to conduct fishery research on the Great Lakes.

  2. Modular biowaste monitoring system

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.

    1975-01-01

    The objective of the Modular Biowaste Monitoring System Program was to generate and evaluate hardware for supporting shuttle life science experimental and diagnostic programs. An initial conceptual design effort established requirements and defined an overall modular system for the collection, measurement, sampling and storage of urine and feces biowastes. This conceptual design effort was followed by the design, fabrication and performance evaluation of a flight prototype model urine collection, volume measurement and sampling capability. No operational or performance deficiencies were uncovered as a result of the performance evaluation tests.

  3. Water-quality data from a sludge disposal test site, St. Petersburg, Florida, November 1973-July 1977

    USGS Publications Warehouse

    Fernandez, Mario

    1978-01-01

    From November 1973 to July 1977, water samples were collected from wells to identify background water-quality conditions and to determine the effects on ground-water quality by St. Petersburg 's sludge-disposal operation (sod farm). Specific conductance and pH were determined in the field. Samples were collected for laboratory determination of selected nitrogen and phosphorus species, sodium, potassium, calcium, magnesium, chloride, trace metals, chemical and biochemical oxygen demand, and coliforms. (Woodard-USGS)

  4. 78 FR 25308 - Proposed Collection; Comment Request; Coal Mine Dust Sampling Devices

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-30

    ...; Coal Mine Dust Sampling Devices AGENCY: Mine Safety and Health Administration, Labor. ACTION: 60-Day.... Background Continuous Personal Dust Monitors (CPDMs) determine the concentration of respirable dust in coal mines. CPDMs must be designed and constructed for coal miners to wear and operate without impeding their...

  5. CTEPP STANDARD OPERATING PROCEDURE FOR VIDEOTAPING CHILD ACTIVITIES (SOP-2.23)

    EPA Science Inventory

    This SOP describes the method for videotaping a preschool child at a home. The CTEPP main study will collect multimedia samples and questionnaire data at the homes of participants (adults and children) during 48-hr sampling periods. Videotaping the activities of 10% of these chi...

  6. US EPA Base Study Standard Operating Procedure for Sampling Volatile Organic Compounds in Indoor Air Using Evacuated Canisters

    EPA Pesticide Factsheets

    The objective of this procedure is to collect a representative sample of air containing volatile organic compound (VOC) contaminants present in an indoor environment using an evacuated canister, and to subsequently analyze the concentration of VOCs, as selected by EPA.

  7. US EPA Base Study Standard Operating Procedure for Sampling and Characterization of Viable and Non-Viable Bioaerosols in Indoor Air

    EPA Pesticide Factsheets

    The objective of the procedure is to collect a representative sample concentration of total airborne fungal spores (viable and non-viable) that may be present in indoor air and in the outdoor air supplied to the space tested.

  8. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR FOOD SAMPLE COMPARISON WITH DIARY AND SHIPMENT (UA-L-13.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for checking the food collections with the food stated as consumed in the 24-Hour Food Diary. The sample is then packaged and shipped for further analysis. This procedure applies to the checking of food samples and shipment ...

  9. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FOOD SAMPLE COMPARISON WITH DIARY AND SHIPMENT (UA-L-13.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for checking the food collections with the food stated as consumed in the 24-Hour Food Diary. The sample is then packaged and shipped to the FDA for further analysis. This procedure applies to the checking of food samples an...

  10. Preliminary performance assessment of biotoxin detection for UWS applications using a MicroChemLab device.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    VanderNoot, Victoria A.; Haroldsen, Brent L.; Renzi, Ronald F.

    2010-03-01

    In a multiyear research agreement with Tenix Investments Pty. Ltd., Sandia has been developing field deployable technologies for detection of biotoxins in water supply systems. The unattended water sensor or UWS employs microfluidic chip based gel electrophoresis for monitoring biological analytes in a small integrated sensor platform. This instrument collects, prepares, and analyzes water samples in an automated manner. Sample analysis is done using the {mu}ChemLab{trademark} analysis module. This report uses analysis results of two datasets collected using the UWS to estimate performance of the device. The first dataset is made up of samples containing ricin at varying concentrations andmore » is used for assessing instrument response and detection probability. The second dataset is comprised of analyses of water samples collected at a water utility which are used to assess the false positive probability. The analyses of the two sets are used to estimate the Receiver Operating Characteristic or ROC curves for the device at one set of operational and detection algorithm parameters. For these parameters and based on a statistical estimate, the ricin probability of detection is about 0.9 at a concentration of 5 nM for a false positive probability of 1 x 10{sup -6}.« less

  11. Improved discovery of NEON data and samples though vocabularies, workflows, and web tools

    NASA Astrophysics Data System (ADS)

    Laney, C. M.; Elmendorf, S.; Flagg, C.; Harris, T.; Lunch, C. K.; Gulbransen, T.

    2017-12-01

    The National Ecological Observatory Network (NEON) is a continental-scale ecological observation facility sponsored by the National Science Foundation and operated by Battelle. NEON supports research on the impacts of invasive species, land use change, and environmental change on natural resources and ecosystems by gathering and disseminating a full suite of observational, instrumented, and airborne datasets from field sites across the U.S. NEON also collects thousands of samples from soil, water, and organisms every year, and partners with numerous institutions to analyze and archive samples. We have developed numerous new technologies to support processing and discovery of this highly diverse collection of data. These technologies include applications for data collection and sample management, processing pipelines specific to each collection system (field observations, installed sensors, and airborne instruments), and publication pipelines. NEON data and metadata are discoverable and downloadable via both a public API and data portal. We solicit continued engagement and advice from the informatics and environmental research communities, particularly in the areas of data versioning, usability, and visualization.

  12. Five-year microbiological monitoring of wards and operating theatres in southern Italy.

    PubMed

    La Fauci, V; Genovese, C; Facciolà, A; Palamara, M A R; Squeri, R

    2017-06-01

    Nosocomial infections are one of the greatest problems in public health. Several studies have highlighted the role played by the hospital environment as a possible source of transmission of nosocomial pathogens. A five-year monitoring of bacterial contamination on healthcare workers hands, surfaces most closely in contact with inpatient wards, operating theatres and "at rest" and "in use" operating theatre air samples. For the samples, we used sterile swabs, contact slides, manual API, and automated VITEK systems for identification. In the five-year period, a total of 9396 samples were collected and analysed. In ward patients, 4398 samplings were carried out with 4.7%, 9.4%, 7%, 10.8% and 7.9% positive results respectively from 2010 to 2014. For hands, 648 samplings were carried out, with a positivity of 40.74%. In operating theatres, 4188 samples were taken, with a positivity of 11.9%. Regarding air in empty and full theatres, 1962 samplings were carried out with a positivity rate equal to 31.9%. The monitoring showed a low rate of contamination with a progressive decrease in the fiveyear period on operating theatres surfaces and hands, while there was an increase in the surgical site wards and in the air of operating rooms. Our investigation has revealed the presence of pathogens on the assessed surfaces and the need for environmental monitoring, which can be a valuable tool for reducing contamination.

  13. Operation of a sampling train for the analysis of environmental species in coal gasification gas-phase process streams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pochan, M.J.; Massey, M.J.

    1979-02-01

    This report discusses the results of actual raw product gas sampling efforts and includes: Rationale for raw product gas sampling efforts; design and operation of the CMU gas sampling train; development and analysis of a sampling train data base; and conclusions and future application of results. The results of sampling activities at the CO/sub 2/-Acceptor and Hygas pilot plants proved that: The CMU gas sampling train is a valid instrument for characterization of environmental parameters in coal gasification gas-phase process streams; depending on the particular process configuration, the CMU gas sampling train can reduce gasifier effluent characterization activity to amore » single location in the raw product gas line; and in contrast to the slower operation of the EPA SASS Train, CMU's gas sampling train can collect representative effluent data at a rapid rate (approx. 2 points per hour) consistent with the rate of change of process variables, and thus function as a tool for process engineering-oriented analysis of environmental characteristics.« less

  14. Standard Operating Procedure for Surface Paint Sample Collection using a Modified Wood Drill Bit with a Variable Speed Portable Electric Drill

    EPA Science Inventory

    This standard operating procedure (SOP) describes a new, rapid, and relatively inexpensive way to remove a precise area of paint from the substrate of building structures in preparation for quantitative analysis. This method has been applied successfully in the laboratory, as we...

  15. Rainfall and runoff quantity and quality data collected at four urban land-use catchments in Fresno, California, October 1981-April 1983

    USGS Publications Warehouse

    Oltmann, R.N.; Guay, J.R.; Shay, J.M.

    1987-01-01

    Data were collected as part of the National Urban Runoff Program to characterize urban runoff in Fresno, California. Rainfall-runoff quantity and quality data are included along with atmospheric dry-deposition and street-surface particulate quality data. The data are presented in figures and tables that reflect four land uses: industrial, single-dwelling residential, multiple-dwelling residential, and commercial. A total of 255 storms were monitored for rainfall and runoff quantity. Runoff samples from 112 of these storms were analyzed for physical, organic, inorganic, and biological constituents. The majority of the remaining storms have pH and specific conductance data only. Ninety-two composite rain samples were collected. Of these, 63 were analyzed for physical, inorganic, and (or) organic constituents. The remaining rainfall samples have pH and specific conductance data only. Nineteen atmospheric deposition and 21 street-particulate samples were collected and analyzed for inorganic and organic constituents. The report also details equipment utilization and operation, and discusses data collection methods. (USGS)

  16. Concentrations of selected pharmaceuticals and antibiotics in south-central Pennsylvania waters, March through September 2006

    USGS Publications Warehouse

    Loper, Connie A.; Crawford, J. Kent; Otto, Kim L.; Manning, Rhonda L.; Meyer, Michael T.; Furlong, Edward T.

    2007-01-01

    This report presents environmental and quality-control data from analyses of 15 pharmaceutical and 31 antibiotic compounds in water samples from streams and wells in south-central Pennsylvania. The analyses are part of a study by the U.S. Geological Survey (USGS) in cooperation with the Pennsylvania Department of Environmental Protection (PADEP) to define concentrations of selected emerging contaminants in streams and well water in Pennsylvania. Sampling was conducted at 11 stream sites and at 6 wells in 9 counties of south-central Pennsylvania. Five of the streams received municipal wastewater and 6 of the streams received runoff from agricultural areas dominated by animal-feeding operations. For all 11 streams, samples were collected at locations upstream and downstream of the municipal effluents or animal-feeding operations. All six wells were in agricultural settings. A total of 120 environmental samples and 21 quality-control samples were analyzed for the study. Samples were collected at each site in March/April, May, July, and September 2006 to obtain information on changes in concentration that could be related to seasonal use of compounds.For streams, 13 pharmaceuticals and 11 antibiotics were detected at least 1 time. Detections included analytical results that were estimated or above the minimum reporting limits. Seventy-eight percent of all detections were analyzed in samples collected downstream from municipal-wastewater effluents. For streams receiving wastewater effluents, the pharmaceuticals caffeine and para-xanthine (a degradation product of caffeine) had the greatest concentrations, 4.75 μg/L (micrograms per liter) and 0.853 μg/L, respectively. Other pharmaceuticals and their respective maximum concentrations were carbamazepine (0.516 μg/L) and ibuprofen (0.277 μg/L). For streams receiving wastewater effluents, the antibiotic azithromycin had the greatest concentration (1.65 μg/L), followed by sulfamethoxazole (1.34 μg/L), ofloxacin (0.329 μg/L), and trimethoprim (0.256 μg/L).For streams receiving runoff from animal-feeding operations, the only pharmaceuticals detected were acetaminophen, caffeine, cotinine, diphenhydramine, and carbamazepine. The maximum concentration for pharmaceuticals was 0.053 μg/L. Three streams receiving runoff from animal-feeding operations had detections of one or more antibiotic compound--oxytetracycline, sulfadimethoxine, sulfamethoxazole, and tylosin. The maximum concentration for antibiotics was 0.157 μg/L. The average number of compounds (pharmaceuticals and antibiotics) detected in sites downstream from animal-feeding operations was three. The average number of compounds detected downstream from municipal-wastewater effluents was 13.For wells used to supply livestock, four compounds were detected--two pharmaceuticals (cotinine and diphenhydramine) and two antibiotics (tylosin and sulfamethoxazole). There were five detections in all the well samples. The maximum concentration detected in well water was for cotinine, estimated to be 0.024 μg/L.Seasonal occurrence of pharmaceutical and antibiotic compounds in stream water varied by compound and site type. At four stream sites, the same compounds were detected in all four seasonal samples. At other sites, pharmaceutical or antibiotic compounds were detected only one time in seasonal samples. Winter samples collected in streams receiving municipalwastewater effluent had the greatest number of compounds detected (21). Research analytical methods were used to determine concentrations for pharmaceuticals and antibiotics. To assist in evaluating the quality of the analyses, detailed information is presented on laboratory methodology and results from qualitycontrol samples. Quality-control data include results for nine blanks, nine duplicate environmental sample pairs, and three laboratory-spiked environmental samples as well as the recoveries of compounds in laboratory surrogates and laboratory reagent spikes.

  17. A New Paradigm for Tissue Diagnostics: Tools and Techniques to Standardize Tissue Collection, Transport, and Fixation.

    PubMed

    Bauer, Daniel R; Otter, Michael; Chafin, David R

    2018-01-01

    Studying and developing preanalytical tools and technologies for the purpose of obtaining high-quality samples for histological assays is a growing field. Currently, there does not exist a standard practice for collecting, fixing, and monitoring these precious samples. There has been some advancement in standardizing collection for the highest profile tumor types, such as breast, where HER2 testing drives therapeutic decisions. This review examines the area of tissue collection, transport, and monitoring of formalin diffusion and details a prototype system that could be used to help standardize tissue collection efforts. We have surveyed recent primary literature sources and conducted several site visits to understand the most error-prone processes in histology laboratories. This effort identified errors that resulted from sample collection techniques and subsequent transport delays from the operating room (OR) to the histology laboratories. We have therefore devised a prototype sample collection and transport concept. The system consists of a custom data logger and cold transport box and takes advantage of a novel cold + warm (named 2 + 2) fixation method. This review highlights the beneficial aspects of standardizing tissue collection, fixation, and monitoring. In addition, a prototype system is introduced that could help standardize these processes and is compatible with use directly in the OR and from remote sites.

  18. External quality-assurance programs managed by the U.S. Geological Survey in support of the National Atmospheric Deposition Program/National Trends Network

    USGS Publications Warehouse

    Latysh, Natalie E.; Wetherbee, Gregory A.

    2005-01-01

    The U.S. Geological Survey, Branch of Quality Systems, operates the external quality-assurance programs for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN). Beginning in 1978, six different programs have been implemented?the intersite-comparison program, the blind-audit program, the sample-handling evaluation program, the field-audit program, the interlaboratory-comparison program, and the collocated-sampler program. Each program was designed to measure error contributed by specific components in the data-collection process. The intersite-comparison program, which was discontinued in 2004, was designed to assess the accuracy and reliability of field pH and specific-conductance measurements made by site operators. The blind-audit and sample-handling evaluation programs, which also were discontinued in 2002 and 2004, respectively, assessed contamination that may result from sampling equipment and routine handling and processing of the wet-deposition samples. The field-audit program assesses the effects of sample handling, processing, and field exposure. The interlaboratory-comparison program evaluates bias and precision of analytical results produced by the contract laboratory for NADP, the Illinois State Water Survey, Central Analytical Laboratory, and compares its performance with the performance of international laboratories. The collocated-sampler program assesses the overall precision of wet-deposition data collected by NADP/NTN. This report documents historical operations and the operating procedures for each of these external quality-assurance programs. USGS quality-assurance information allows NADP/NTN data users to discern between actual environmental trends and inherent measurement variability.

  19. A quality-assurance assessment for constituents reported by the national atmospheric deposition program and the national trends network

    NASA Astrophysics Data System (ADS)

    See, Randolph B.; Schroder, LeRoy J.; Willoughby, Timothy C.

    A continuing quality-assurance program has been operated by the U.S. Geological Survey to evaluate any bias introduced by routine handling, shipping, and laboratory analyses of wet-deposition samples collected in the National Atmospheric Deposition Program (NADP) and National Trends Network (NTN). Blind-audit samples having a variety of constituent concentrations and values were selected. Only blind-audit samples with constituent concentrations and values less than the 95th-percentile concentration for natural wet-deposition samples were included in the analysis. Of the major ions, there was a significant increase of Ca 2+, Mg 2+, Na 2+, K +, SO 42- and Cl -1 in samples handled according to standard protocols and shipped in NADP/NTN sample-collection buckets. For 1979-1987, graphs of smoothed data showing the estimated contamination in blind-audit samples indicate a decrease in the median concentration and ranges of Ca 2+, Mg 2+ and SO 42- contamination of blind-audit samples shipped in sample-collection buckets. Part of the contamination detected in blind-audit samples can be attributed to contact with the sample-collection bucket and lid; however, additional sources also seem to contaminate the blind-audit sample. Apparent decreases in the magnitude and range of sample contamination may be caused by differences in sample-collection bucket- and lid-washing procedures by the NADP/NTN Central Analytical Laboratory. Although the degree of bias is minimal for most constituents, summaries of the NADP/NTN data base may contain overestimates of Ca 2+, Mg 2+, Na -, K + and SO 42- and Cl - concentrations, and underestimates of H + concentrations.

  20. A quality-assurance assessment for constituents reported by the National Atmospheric Deposition Program and the National Trends Network

    USGS Publications Warehouse

    See, R.B.; Schroder, L.J.; Willoughby, T.C.

    1989-01-01

    A continuing quality-assurance program has been operated by the U.S. Geographical Survey to evaluate any bias introduced by routine handling, shipping, and laboratory analyses of wet-deposition samples collected in the National Atmospheric Deposition Program (NADP) and National Trends Network (NTN). Blind-audit samples having a variety of constituent concentrations and values were selected. Only blind-audit samples with constituent concentrations and values less than the 95th-percentile concentration for natural wet-deposition samples were included in the analysis. Of the major ions, there was a significant increase of Ca2+, Mg2+, K+ SO42+ and Cl- in samples handled according to standard protocols and shipped in NADP/NTN sample-collection buckets. For 1979-1987, graphs of smoothed data showing the estimated contaminations in blind-audit samples indicate a decrease in the median concentration and ranges of Ca2+, Mg2+ and SO42- contamination of blind-audit samples shipped in sample-collection buckets. Part of the contamination detected in blind-audit samples can be attributed to contact with the sample-collection bucket and lid; however, additional sources also seem to contaminate the blind-audit sample. Apparent decreases in the magnitude and range of sample contamination may be caused by differences in sample-collection bucket- and lid-washing procedures by the NADP/NTN Central Analytical Laboratory. Although the degree of bias is minimal for most constituents, summaries of the NADP/NTN data base may contain overestimates of Ca2+, Mg2+, Na-, K+, SO42- and Cl- concentrations, and underestimates of H+ concentrations.

  1. Determinants of isocyanate exposures in auto body repair and refinishing shops.

    PubMed

    Woskie, S R; Sparer, J; Gore, R J; Stowe, M; Bello, D; Liu, Y; Youngs, F; Redlich, C; Eisen, E; Cullen, M

    2004-07-01

    As part of the Survey of Painters and Repairers of Auto bodies by Yale (SPRAY), the determinants of isocyanate exposure in auto body repair shops were evaluated. Measurements (n = 380) of hexamethylene diisocyanate-based monomer and polyisocyanate and isophorone diisocyanate-based polyisocyanate were collected from 33 auto body shops. The median total reactive isocyanate concentrations expressed as mass concentration of the NCO functional group were: 206 microg NCO/m3 for spray operations; 0.93 microg NCO/m3 for samples collected in the vicinity of spray operations done on the shop floor (near spray); 0.05 microg NCO/m3 for office or other shop areas adjacent to spray areas (workplace background); 0.17 microg NCO/m3 for paint mixing and gun cleaning operations (mixing); 0.27 microg NCO/m3 for sanding operations. Exposure determinants for the sample NCO mass load were identified using linear regression, tobit regression and logistic regression models. For spray samples in a spray booth the significant determinants were the number of milliliters of NCO applied, the gallons of clear coat used by the shop each month and the type of spray booth used (custom built crossdraft, prefabricated crossdraft or downdraft/semi-downdraft). For near spray (bystander) samples, outdoor temperature >65 degrees F (18 degrees C) and shop size >5000 feet2 (465 m2) were significant determinants of exposure levels. For workplace background samples the shop annual income was the most important determinant. For sanding samples, the shop annual income and outdoor temperature >65 degrees F (18 degrees C) were the most significant determinants. Identification of these key exposure determinants will be useful in targeting exposure evaluation and control efforts to reduce isocyanate exposures.

  2. Herbicide sorption to fine particulate matter suspended downwind of agricultural operations: field and laboratory investigations.

    PubMed

    Clymo, Amelia S; Shin, Jin Young; Holmen, Britt A

    2005-01-15

    Tillage-induced erosion of herbicides bound to airborne soil particles has not been quantified as a mechanism for offsite herbicide transport. This study quantifies the release of two preemergent herbicides, metolachlor and pendimethalin, to the atmosphere as gas- and particle-phase species during soil incorporation operations. Fine particulate matter (PM2.5) and gas-phase samples were collected at three sampling heights during herbicide disking into the soil in Davis, CA, in May 2000 and May 2001 using filter/PUF sampling. Quartz fiber filters (QFFs) were used in May 2000, and Teflon membrane filters (TMFs) were used in May 2001. The field data were combined with laboratory filter/PUF partitioning experiments to account for adsorption to the filter surfaces and quantify the mass of PM2.5-bound herbicides in the field samples. Laboratory results indicate a significant adsorption of metolachlor, but not pendimethalin, to the quartz filter surfaces. Metolachlor partitioning to PM2.5 collected on TMF filters resulted in corrected PM2.5 field partition coefficient values, Kp,corr = Cp/Cg, of approximately 10(-3.5) m3/microg, indicating its preference for the gas phase. Pendimethalin exhibited more semivolatile behavior,with Kp,corr values that ranged from 10(-3) to 10(-1) m3/ microg and increased with sampling height and distance downwind of the operation. An increase in pendimethalin enrichment at a height of 5 m suggests winnowing of finer, more sorptive soil components with corresponding higher transport potential. Pendimethalin was enriched in the PM2.5 samples by up to a factor of 250 compared to the field soil, indicating thatfurther research on the processes controlling the generation of PM-bound herbicides during agricultural operations is warranted to enable prediction of off-site mass fluxes by this mechanism.

  3. Development and Flight Testing of an Adaptable Vehicle Health-Monitoring Architecture

    NASA Technical Reports Server (NTRS)

    Woodard, Stanley E.; Coffey, Neil C.; Gonzalez, Guillermo A.; Woodman, Keith L.; Weathered, Brenton W.; Rollins, Courtney H.; Taylor, B. Douglas; Brett, Rube R.

    2003-01-01

    Development and testing of an adaptable wireless health-monitoring architecture for a vehicle fleet is presented. It has three operational levels: one or more remote data acquisition units located throughout the vehicle; a command and control unit located within the vehicle; and a terminal collection unit to collect analysis results from all vehicles. Each level is capable of performing autonomous analysis with a trained adaptable expert system. The remote data acquisition unit has an eight channel programmable digital interface that allows the user discretion for choosing type of sensors; number of sensors, sensor sampling rate, and sampling duration for each sensor. The architecture provides framework for a tributary analysis. All measurements at the lowest operational level are reduced to provide analysis results necessary to gauge changes from established baselines. These are then collected at the next level to identify any global trends or common features from the prior level. This process is repeated until the results are reduced at the highest operational level. In the framework, only analysis results are forwarded to the next level to reduce telemetry congestion. The system's remote data acquisition hardware and non-analysis software have been flight tested on the NASA Langley B757's main landing gear.

  4. Automated process for solvent separation of organic/inorganic substance

    DOEpatents

    Schweighardt, F.K.

    1986-07-29

    There is described an automated process for the solvent separation of organic/inorganic substances that operates continuously and unattended and eliminates potential errors resulting from subjectivity and the aging of the sample during analysis. In the process, metered amounts of one or more solvents are passed sequentially through a filter containing the sample under the direction of a microprocessor control apparatus. The mixture in the filter is agitated by ultrasonic cavitation for a timed period and the filtrate is collected. The filtrate of each solvent extraction is collected individually and the residue on the filter element is collected to complete the extraction process. 4 figs.

  5. Automated process for solvent separation of organic/inorganic substance

    DOEpatents

    Schweighardt, Frank K.

    1986-01-01

    There is described an automated process for the solvent separation of organic/inorganic substances that operates continuously and unattended and eliminates potential errors resulting from subjectivity and the aging of the sample during analysis. In the process, metered amounts of one or more solvents are passed sequentially through a filter containing the sample under the direction of a microprocessor control apparatus. The mixture in the filter is agitated by ultrasonic cavitation for a timed period and the filtrate is collected. The filtrate of each solvent extraction is collected individually and the residue on the filter element is collected to complete the extraction process.

  6. Automated apparatus for solvent separation of a coal liquefaction product stream

    DOEpatents

    Schweighardt, Frank K.

    1985-01-01

    An automated apparatus for the solvent separation of a coal liquefaction product stream that operates continuously and unattended and eliminates potential errors resulting from subjectivity and the aging of the sample during analysis. In use of the apparatus, metered amounts of one or more solvents are passed sequentially through a filter containing the sample under the direction of a microprocessor control means. The mixture in the filter is agitated by means of ultrasonic cavitation for a timed period and the filtrate is collected. The filtrate of each solvent extraction is collected individually and the residue on the filter element is collected to complete the extraction process.

  7. Collecting cometary soil samples? Development of the ROSETTA sample acquisition system

    NASA Technical Reports Server (NTRS)

    Coste, P. A.; Fenzi, M.; Eiden, Michael

    1993-01-01

    In the reference scenario of the ROSETTA CNRS mission, the Sample Acquisition System is mounted on the Comet Lander. Its tasks are to acquire three kinds of cometary samples and to transfer them to the Earth Return Capsule. Operations are to be performed in vacuum and microgravity, on a probably rough and dusty surface, in a largely unknown material, at temperatures in the order of 100 K. The concept and operation of the Sample Acquisition System are presented. The design of the prototype corer and surface sampling tool, and of the equipment for testing them at cryogenic temperatures in ambient conditions and in vacuum in various materials representing cometary soil, are described. Results of recent preliminary tests performed in low temperature thermal vacuum in a cometary analog ice-dust mixture are provided.

  8. Asbestos fiber release from the brake pads of overhead industrial cranes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spencer, J.W.; Plisko, M.J.; Balzer, J.L.

    The purpose of this evaluation was to determine the actual contribution of airborne asbestos fibers to the work environment from the operation of overhead cranes and hoists that use asbestos composition brake pads. The evaluation was conducted in a working manufacturing facility. Other potential sources of asbestos were accounted for by visual inspection and background air monitoring. An overhead crane assembly comprised of a trolley and two hoists was employed for this study. The crane was operated for two consecutive eight-hour shifts representative of a heavy-duty cycle. Forty-four personal and area air samples were collected during the assessment. Asbestos fibersmore » were analyzed for by phase contrast (NIOSH 7400), and transmission electron (NIOSH 7402) microscopy methods. Eight-hour time-weighted average (TWA) asbestos fiber concentrations ranges from <0.005 to 0.011 fibers/cc (PCM), and <0.0026 to <0.0094f/cc (TEM). There were no asbestos fibers detected by the TEM method from air samples collected during the operation of the cranes.« less

  9. Asbestos fiber release from the brake pads of overhead industrial cranes.

    PubMed

    Spencer, J W; Plisko, M J; Balzer, J L

    1999-06-01

    The purpose of this evaluation was to determine the actual contribution of airborne asbestos fibers to the work environment from the operation of overhead cranes and hoists that use asbestos composition brake pads. The evaluation was conducted in a working manufacturing facility. Other potential sources of asbestos were accounted for by visual inspection and background air monitoring. An overhead crane assembly comprised of a trolley and two hoists was employed for this study. The crane was operated for two consecutive eight-hour shifts representative of a heavy-duty cycle. Forty-four personal and area air samples were collected during the assessment. Asbestos fibers were analyzed for by phase contrast (NIOSH 7400), and transmission electron (NIOSH 7402) microscopy methods. Eight-hour time-weighted average (TWA) asbestos fiber concentrations ranged from < 0.005 to 0.011 fibers/cc (PCM), and < 0.0026 to < 0.0094 f/cc (TEM). There were no asbestos fibers detected by the TEM method from air samples collected during the operation of the cranes.

  10. SAMURAI: Polar AUV-Based Autonomous Dexterous Sampling

    NASA Astrophysics Data System (ADS)

    Akin, D. L.; Roberts, B. J.; Smith, W.; Roderick, S.; Reves-Sohn, R.; Singh, H.

    2006-12-01

    While autonomous undersea vehicles are increasingly being used for surveying and mapping missions, as of yet there has been little concerted effort to create a system capable of performing physical sampling or other manipulation of the local environment. This type of activity has typically been performed under teleoperated control from ROVs, which provides high-bandwidth real-time human direction of the manipulation activities. Manipulation from an AUV will require a completely autonomous sampling system, which implies both advanced technologies such as machine vision and autonomous target designation, but also dexterous robot manipulators to perform the actual sampling without human intervention. As part of the NASA Astrobiology Science and Technology for Exploring the Planets (ASTEP) program, the University of Maryland Space Systems Laboratory has been adapting and extending robotics technologies developed for spacecraft assembly and maintenance to the problem of autonomous sampling of biologicals and soil samples around hydrothermal vents. The Sub-polar ice Advanced Manipulator for Universal Sampling and Autonomous Intervention (SAMURAI) system is comprised of a 6000-meter capable six-degree-of-freedom dexterous manipulator, along with an autonomous vision system, multi-level control system, and sampling end effectors and storage mechanisms to allow collection of samples from vent fields. SAMURAI will be integrated onto the Woods Hole Oceanographic Institute (WHOI) Jaguar AUV, and used in Arctic during the fall of 2007 for autonomous vent field sampling on the Gakkel Ridge. Under the current operations concept, the JAGUAR and PUMA AUVs will survey the water column and localize on hydrothermal vents. Early mapping missions will create photomosaics of the vents and local surroundings, allowing scientists on the mission to designate desirable sampling targets. Based on physical characteristics such as size, shape, and coloration, the targets will be loaded into the SAMURAI control system, and JAGUAR (with SAMURAI mounted to the lower forward hull) will return to the designated target areas. Once on site, vehicle control will be turned over to the SAMURAI controller, which will perform vision-based guidance to the sampling site and will then ground the AUV to the sea bottom for stability. The SAMURAI manipulator will collect samples, such as sessile biologicals, geological samples, and (potentially) vent fluids, and store the samples for the return trip. After several hours of sampling operations on one or several sites, JAGUAR control will be returned to the WHOI onboard controller for the return to the support ship. (Operational details of AUV operations on the Gakkel Ridge mission are presented in other papers at this conference.) Between sorties, SAMURAI end effectors can be changed out on the surface for specific targets, such as push cores or larger biologicals such as tube worms. In addition to the obvious challenges in autonomous vision-based manipulator control from a free-flying support vehicle, significant development challenges have been the design of a highly capable robotic arm within the mass limitations (both wet and dry) of the JAGUAR vehicle, the development of a highly robust manipulator with modular maintenance units for extended polar operations, and the creation of a robot-based sample collection and holding system for multiple heterogeneous samples on a single extended sortie.

  11. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR PREPARATION OF FILTERS AND PUF FOR FIELD COLLECTION OF METALS AND PESTICIDES IN AIR (BCO-L-2.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for pre-cleaning filters and polyurethane foam (PUF) plug prior to air sampling with these media. The sampling media are used for sampling indoor air, outdoor air, and personal air. This procedure was followed to ensure consi...

  12. Evaluating fungal populations by genera/species on wide body commercial passenger aircraft and in airport terminals.

    PubMed

    McKernan, Lauralynn Taylor; Burge, Harriet; Wallingford, Kenneth M; Hein, Misty J; Herrick, Robert

    2007-04-01

    Given the potential health effects of fungi and the amount of time aircrew and passengers spend inside aircraft, it is important to study fungal populations in the aircraft environment. Research objectives included documenting the genera/species of airborne culturable fungal concentrations and total spore concentrations on a twin-aisle wide body commercial passenger aircraft. Twelve flights between 4.5 and 6.5 h in duration on Boeing 767 (B-767) aircraft were evaluated. Two air cooling packs and 50% recirculation rate (i.e. 50:50 mix of outside air and filtered inside air) were utilized during flight operations. Passenger occupancy rates varied from 67 to 100%. N-6 impactors and total spore traps were used to collect sequential, triplicate air samples in the front and rear of coach class during six sampling intervals throughout each flight: boarding, mid-climb, early cruise, mid-cruise, late cruise and deplaning. Comparison air samples were also collected inside and outside the airport terminals at the origin and destination cities resulting in a total of 522 culturable and 517 total spore samples. A total of 45 surface wipe samples were collected using swabs onboard the aircraft and inside the airport terminals. A variety of taxa were observed in the culturable and total spore samples. A frequency analysis of the fungal data indicated that Cladosporium, Aspergillus and Penicillium were predominant genera in the culturable samples whereas Cladosporium, Basidiospores and Penicillium/Aspergillus were predominant in the total spore samples. Fungal populations observed inside the aircraft were comprised of similar genera, detected significantly less frequently and with lower mean concentrations than those observed in typical office buildings. Although sources internal to the aircraft could not be ruled out, our data demonstrate the importance of passenger activity as the source of the fungi observed on aircraft. Isolated fungal peak events occurred occasionally when concentrations of a particular genus or species rose sharply inside the cabin for a limited period. Overall, our research demonstrates that on the sampled flights the B-767 filtration system operated efficiently to remove fungal spores when two air cooling packs and 50% recirculation rate were utilized during flight operations.

  13. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR IDENTIFICATION NUMBERS FOR SAMPLES AND FORMS (G03)

    EPA Science Inventory

    The purpose of this SOP is to indicate the proper method for assigning unique Identification Numbers for all samples taken and forms used in the collection of NHEXAS Pilot Studies. All data tracking procedures were built upon these ID numbers. Inspection of these ID numbers pro...

  14. Electron Microscopist | Center for Cancer Research

    Cancer.gov

    PROGRAM DESCRIPTION The Cancer Research Technology Program (CRTP) develops and implements emerging technology, cancer biology expertise and research capabilities to accomplish NCI research objectives. The CRTP is an outward-facing, multi-disciplinary hub purposed to enable the external cancer research community and provides dedicated support to NCI’s intramural Center for Cancer Research (CCR). The dedicated units provide electron microscopy, protein characterization, protein expression, optical microscopy and genetics. These research efforts are an integral part of CCR at the Frederick National Laboratory for Cancer Research (FNLCR). CRTP scientists also work collaboratively with intramural NCI investigators to provide research technologies and expertise. KEY ROLES/RESPONSIBILITIES - THIS POSITION IS CONTINGENT UPON FUNDING APPROVAL The Electron Microscopist will: Operate ultramicrotomes (Leica) and other instrumentation related to the preparation of embedded samples for EM (TEM and SEM) Operate TEM microscopes, (specifically Hitachi, FEI T20 and FEI T12) as well as SEM microscopes (Hitachi); task will include loading samples, screening, and performing data collection for a variety of samples: from cells to proteins Manage maintenance for the TEM and SEM microscopes Provide technical advice to investigators on sample preparation and data collection

  15. Operational Toxicology Research

    DTIC Science & Technology

    2006-08-01

    Activity Relationships CQSARs) assessments of Air Force chemicals. Assay samples Completed collected for biochemical and molecular endpoints and...techniques for perchlorate in water, groundwater, soil and biological matrices such as blood, urine , milk. thyroid and other tissues required for...in vivo laboratory animal experiments with a l710D70ll Toxicological Response in Urine Using variety of known target organ toxicants, collect urine

  16. In-Situ Operations and Planning for the Mars Science Laboratory Robotic Arm: The First 200 Sols

    NASA Technical Reports Server (NTRS)

    Robinson, M.; Collins, C.; Leger, P.; Carsten, J.; Tompkins, V.; Hartman, F.; Yen, J.

    2013-01-01

    The Robotic Arm (RA) has operated for more than 200 Martian solar days (or sols) since the Mars Science Laboratory rover touched down in Gale Crater on August 5, 2012. During the first seven months on Mars the robotic arm has performed multiple contact science sols including the positioning of the Alpha Particle X-Ray Spectrometer (APXS) and/or Mars Hand Lens Imager (MAHLI) with respect to rocks or loose regolith targets. The RA has supported sample acquisition using both the scoop and drill, sample processing with CHIMRA (Collection and Handling for In- Situ Martian Rock Analysis), and delivery of sample portions to the observation tray, and the SAM (Sample Analysis at Mars) and CHEMIN (Chemistry and Mineralogy) science instruments. This paper describes the planning and execution of robotic arm activities during surface operations, and reviews robotic arm performance results from Mars to date.

  17. Prevalence and genotypes of enterocytozoon bieneusi in weaned beef calves on cow-calf operations in the United States

    USDA-ARS?s Scientific Manuscript database

    To determine the prevalence and genotype distribution of Enterocytozoon bieneusi in weaned beef calves in the United States, fecal samples were collected from 819 calves (6-18 months of age) from 49 operations. Feces were sieved and subjected to density gradient centrifugation to remove fecal debri...

  18. 40 CFR 61.242-5 - Standards: Sampling connecting systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Collect and recycle the purged process fluid; or (3) Be designed and operated to capture and transport all the purged process fluid to a control device that complies with the requirements of § 61.242-11; or (4... operated in compliance with the provisions of 40 CFR part 63, subpart G, applicable to Group 1 wastewater...

  19. 40 CFR 61.242-5 - Standards: Sampling connecting systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Collect and recycle the purged process fluid; or (3) Be designed and operated to capture and transport all the purged process fluid to a control device that complies with the requirements of § 61.242-11; or (4... operated in compliance with the provisions of 40 CFR part 63, subpart G, applicable to Group 1 wastewater...

  20. Microchemical Analysis Of Space Operation Debris

    NASA Technical Reports Server (NTRS)

    Cummings, Virginia J.; Kim, Hae Soo

    1995-01-01

    Report discusses techniques used in analyzing debris relative to space shuttle operations. Debris collected from space shuttle, expendable launch vehicles, payloads carried by space shuttle, and payloads carried by expendable launch vehicles. Optical microscopy, scanning electron microscopy with energy-dispersive spectrometry, analytical electron microscopy with wavelength-dispersive spectrometry, and X-ray diffraction chosen as techniques used in examining samples of debris.

  1. Survalytics: An Open-Source Cloud-Integrated Experience Sampling, Survey, and Analytics and Metadata Collection Module for Android Operating System Apps

    PubMed Central

    Mackey, Sean

    2016-01-01

    Background We describe here Survalytics, a software module designed to address two broad areas of need. The first area is in the domain of surveys and app analytics: developers of mobile apps in both academic and commercial environments require information about their users, as well as how the apps are being used, to understand who their users are and how to optimally approach app development. The second area of need is in the field of ecological momentary assessment, also referred to as experience sampling: researchers in a wide variety of fields, spanning from the social sciences to psychology to clinical medicine, would like to be able to capture daily or even more frequent data from research subjects while in their natural environment. Objective Survalytics is an open-source solution for the collection of survey responses as well as arbitrary analytic metadata from users of Android operating system apps. Methods Surveys may be administered in any combination of one-time questions and ongoing questions. The module may be deployed as a stand-alone app for experience sampling purposes or as an add-on to existing apps. The module takes advantage of free-tier NoSQL cloud database management offered by the Amazon Web Services DynamoDB platform to package a secure, flexible, extensible data collection module. DynamoDB is capable of Health Insurance Portability and Accountability Act compliant storage of personal health information. Results The provided example app may be used without modification for a basic experience sampling project, and we provide example questions for daily collection of blood glucose data from study subjects. Conclusions The module will help researchers in a wide variety of fields rapidly develop tailor-made Android apps for a variety of data collection purposes. PMID:27261155

  2. Survalytics: An Open-Source Cloud-Integrated Experience Sampling, Survey, and Analytics and Metadata Collection Module for Android Operating System Apps.

    PubMed

    O'Reilly-Shah, Vikas; Mackey, Sean

    2016-06-03

    We describe here Survalytics, a software module designed to address two broad areas of need. The first area is in the domain of surveys and app analytics: developers of mobile apps in both academic and commercial environments require information about their users, as well as how the apps are being used, to understand who their users are and how to optimally approach app development. The second area of need is in the field of ecological momentary assessment, also referred to as experience sampling: researchers in a wide variety of fields, spanning from the social sciences to psychology to clinical medicine, would like to be able to capture daily or even more frequent data from research subjects while in their natural environment. Survalytics is an open-source solution for the collection of survey responses as well as arbitrary analytic metadata from users of Android operating system apps. Surveys may be administered in any combination of one-time questions and ongoing questions. The module may be deployed as a stand-alone app for experience sampling purposes or as an add-on to existing apps. The module takes advantage of free-tier NoSQL cloud database management offered by the Amazon Web Services DynamoDB platform to package a secure, flexible, extensible data collection module. DynamoDB is capable of Health Insurance Portability and Accountability Act compliant storage of personal health information. The provided example app may be used without modification for a basic experience sampling project, and we provide example questions for daily collection of blood glucose data from study subjects. The module will help researchers in a wide variety of fields rapidly develop tailor-made Android apps for a variety of data collection purposes.

  3. Dredging Operations Technical Support Program: Engineering Design and Environmental Assessment of Dredged Material Overflow from Hydraulically Filled Hopper Barges in Mobile Bay, Alabama

    DTIC Science & Technology

    1990-09-01

    turbid estuarine habitats such as Mobile Bay are very tolerant of moderately high concentrations of suspended sediments and thin layers of sediment...GULF OF MEXIC BAYOU 4M 2CAE SI2LTK Fiur 3. DsrbuinoAedmnTyesi oie a fo IsphordingLT anCLmb190 PART III: DREDGING EQUIPMENT AND OPERATIONAL TECHNIQUES...increase in ambient turbidity was noted. Water samples were collected at surface, middepth, and bottom. The sampling boats proceeded across their

  4. Self-collected versus clinician-collected sampling for sexually transmitted infections: a systematic review and meta-analysis protocol.

    PubMed

    Taylor, Darlene; Lunny, Carole; Wong, Tom; Gilbert, Mark; Li, Neville; Lester, Richard; Krajden, Mel; Hoang, Linda; Ogilvie, Gina

    2013-10-10

    Three meta-analyses and one systematic review have been conducted on the question of whether self-collected specimens are as accurate as clinician-collected specimens for STI screening. However, these reviews predate 2007 and did not analyze rectal or pharyngeal collection sites. Currently, there is no consensus on which sampling method is the most effective for the diagnosis of genital chlamydia (CT), gonorrhea (GC) or human papillomavirus (HPV) infection. Our meta-analysis aims to be comprehensive in that it will examine the evidence of whether self-collected vaginal, urine, pharyngeal and rectal specimens provide as accurate a clinical diagnosis as clinician-collected samples (reference standard). Eligible studies include both randomized and non-randomized controlled trials, pre- and post-test designs, and controlled observational studies. The databases that will be searched include the Cochrane Database of Systematic Reviews, Web of Science, Database of Abstracts of Reviews of Effects (DARE), EMBASE and PubMed/Medline. Data will be abstracted independently by two reviewers using a standardized pre-tested data abstraction form. Heterogeneity will be assessed using the Q2 test. Sensitivity and specificity estimates with 95% confidence intervals as well as negative and positive likelihood ratios will be pooled and weighted using random effects meta-analysis, if appropriate. A hierarchical summary receiver operating characteristics curve for self-collected specimens will be generated. This synthesis involves a meta-analysis of self-collected samples (urine, vaginal, pharyngeal and rectal swabs) versus clinician-collected samples for the diagnosis of CT, GC and HPV, the most prevalent STIs. Our systematic review will allow patients, clinicians and researchers to determine the diagnostic accuracy of specimens collected by patients compared to those collected by clinicians in the detection of chlamydia, gonorrhea and HPV.

  5. A new sampler for stratified lagoon chemical and microbiological assessments.

    PubMed

    McLaughlin, M R; Brooks, J P; Adeli, A

    2014-07-01

    A sampler was needed for a spatial and temporal study of microbial and chemical stratification in a large swine manure lagoon that was known to contain zoonotic bacteria. Conventional samplers were limited to collections of surface water samples near the bank or required a manned boat. A new sampler was developed to allow simultaneous collection of multiple samples at different depths, up to 2.3 m, without a manned boat. The sampler was tethered for stability, used remote control (RC) for sample collection, and accommodated rapid replacement of sterile tubing modules and sample containers. The sampler comprised a PVC pontoon with acrylic deck and watertight enclosures, for a 12 VDC gearmotor, to operate the collection module, and vacuum system, to draw samples into reusable autoclavable tubing and 250-mL bottles. Although designed primarily for water samples, the sampler was easily modified to collect sludge. The sampler held a stable position during deployment, created minimal disturbance in the water column, and was readily cleaned and sanitized for transport. The sampler was field tested initially in a shallow fresh water lake and subsequently in a swine manure treatment lagoon. Analyses of water samples from the lagoon tests showed that chemical and bacterial levels, pH, and EC did not differ between 0.04, 0.47, and 1.0 m depths, but some chemical and bacterial levels differed between winter and spring collections. These results demonstrated the utility of the sampler and suggested that future manure lagoon studies employ fewer or different depths and more sampling dates.

  6. Evaluation of ELISA screening test for detecting aflatoxin in biogenic dust samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Durant, J.T.

    Aflatoxin is a carcinogenic chemical that is sometimes produced when agricultural commodities are infested by the fungi Aspergillus flavus and A. Parasiticus. Aflatoxin has been found to be present in air samples taken around persons handling materials likely to be contaminated. The purpose of this investigation was to demonstrate the feasibility of using an Enzyme Linked Immunosorbent Assay (ELISA) test kit that was developed to screen for aflatoxin in bulk agricultural commodities, to an air sample. Samples were taken from two environments likely to be contaminated with aflatoxin, a dairy farm feed mixing operation and a peanut bagging operation. Themore » dust collected from these environments was considered to be biogenic, in that it originated primarily from biological materials.« less

  7. Collection of Viable Aerosolized Influenza Virus and Other Respiratory Viruses in a Student Health Care Center through Water-Based Condensation Growth

    PubMed Central

    Pan, Maohua; Bonny, Tania S.; Loeb, Julia; Jiang, Xiao; Eiguren-Fernandez, Arantzazu; Hering, Susanne; Fan, Z. Hugh; Wu, Chang-Yu

    2017-01-01

    ABSTRACT The dynamics and significance of aerosol transmission of respiratory viruses are still controversial, for the major reasons that virus aerosols are inefficiently collected by commonly used air samplers and that the collected viruses are inactivated by the collection method. Without knowledge of virus viability, infection risk analyses lack accuracy. This pilot study was performed to (i) determine whether infectious (viable) respiratory viruses in aerosols could be collected from air in a real world environment by the viable virus aerosol sampler (VIVAS), (ii) compare and contrast the efficacy of the standard bioaerosol sampler, the BioSampler, with that of the VIVAS for the collection of airborne viruses in a real world environment, and (iii) gain insights for the use of the VIVAS for respiratory virus sampling. The VIVAS operates via a water vapor condensation process to enlarge aerosolized virus particles to facilitate their capture. A variety of viable human respiratory viruses, including influenza A H1N1 and H3N2 viruses and influenza B viruses, were collected by the VIVAS located at least 2 m from seated patients, during a late-onset 2016 influenza virus outbreak. Whereas the BioSampler when operated following our optimized parameters also collected virus aerosols, it was nevertheless overall less successful based on a lower frequency of virus isolation in most cases. This side-by-side comparison highlights some limitations of past studies based on impingement-based sampling, which may have generated false-negative results due to either poor collection efficiency and/or virus inactivation due to the collection process. IMPORTANCE The significance of virus aerosols in the natural transmission of respiratory diseases has been a contentious issue, primarily because it is difficult to collect or sample virus aerosols using currently available air sampling devices. We tested a new air sampler based on water vapor condensation for efficient sampling of viable airborne respiratory viruses in a student health care center as a model of a real world environment. The new sampler outperformed the industry standard device (the SKC BioSampler) in the collection of natural virus aerosols and in maintaining virus viability. These results using the VIVAS indicate that respiratory virus aerosols are more prevalent and potentially pose a greater inhalation biohazard than previously thought. The VIVAS thus appears to be a useful apparatus for microbiology air quality tests related to the detection of viable airborne viruses. PMID:29034325

  8. Collection of Viable Aerosolized Influenza Virus and Other Respiratory Viruses in a Student Health Care Center through Water-Based Condensation Growth.

    PubMed

    Pan, Maohua; Bonny, Tania S; Loeb, Julia; Jiang, Xiao; Lednicky, John A; Eiguren-Fernandez, Arantzazu; Hering, Susanne; Fan, Z Hugh; Wu, Chang-Yu

    2017-01-01

    The dynamics and significance of aerosol transmission of respiratory viruses are still controversial, for the major reasons that virus aerosols are inefficiently collected by commonly used air samplers and that the collected viruses are inactivated by the collection method. Without knowledge of virus viability, infection risk analyses lack accuracy. This pilot study was performed to (i) determine whether infectious (viable) respiratory viruses in aerosols could be collected from air in a real world environment by the vi able v irus a erosol s ampler (VIVAS), (ii) compare and contrast the efficacy of the standard bioaerosol sampler, the BioSampler, with that of the VIVAS for the collection of airborne viruses in a real world environment, and (iii) gain insights for the use of the VIVAS for respiratory virus sampling. The VIVAS operates via a water vapor condensation process to enlarge aerosolized virus particles to facilitate their capture. A variety of viable human respiratory viruses, including influenza A H1N1 and H3N2 viruses and influenza B viruses, were collected by the VIVAS located at least 2 m from seated patients, during a late-onset 2016 influenza virus outbreak. Whereas the BioSampler when operated following our optimized parameters also collected virus aerosols, it was nevertheless overall less successful based on a lower frequency of virus isolation in most cases. This side-by-side comparison highlights some limitations of past studies based on impingement-based sampling, which may have generated false-negative results due to either poor collection efficiency and/or virus inactivation due to the collection process. IMPORTANCE The significance of virus aerosols in the natural transmission of respiratory diseases has been a contentious issue, primarily because it is difficult to collect or sample virus aerosols using currently available air sampling devices. We tested a new air sampler based on water vapor condensation for efficient sampling of viable airborne respiratory viruses in a student health care center as a model of a real world environment. The new sampler outperformed the industry standard device (the SKC BioSampler) in the collection of natural virus aerosols and in maintaining virus viability. These results using the VIVAS indicate that respiratory virus aerosols are more prevalent and potentially pose a greater inhalation biohazard than previously thought. The VIVAS thus appears to be a useful apparatus for microbiology air quality tests related to the detection of viable airborne viruses.

  9. PubMed Central

    Genovese, C.; Facciolà, A.; Palamara, M.A.R.; Squeri, R.

    2017-01-01

    Summary Introduction. Nosocomial infections are one of the greatest problems in public health. Several studies have highlighted the role played by the hospital environment as a possible source of transmission of nosocomial pathogens. Methods. A five-year monitoring of bacterial contamination on healthcare workers hands, surfaces most closely in contact with inpatient wards, operating theatres and "at rest" and "in use" operating theatre air samples. For the samples, we used sterile swabs, contact slides, manual API, and automated VITEK systems for identification. Results. In the five-year period, a total of 9396 samples were collected and analysed. In ward patients, 4398 samplings were carried out with 4.7%, 9.4%, 7%, 10.8% and 7.9% positive results respectively from 2010 to 2014. For hands, 648 samplings were carried out, with a positivity of 40.74%. In operating theatres, 4188 samples were taken, with a positivity of 11.9%. Regarding air in empty and full theatres, 1962 samplings were carried out with a positivity rate equal to 31.9%. The monitoring showed a low rate of contamination with a progressive decrease in the fiveyear period on operating theatres surfaces and hands, while there was an increase in the surgical site wards and in the air of operating rooms. Conclusions. Our investigation has revealed the presence of pathogens on the assessed surfaces and the need for environmental monitoring, which can be a valuable tool for reducing contamination. PMID:28900357

  10. Potential of Probing the Lunar Regolith using Rover-Mounted Ground Penetrating Radar: Moses Lake Dune Field Analog Study

    NASA Technical Reports Server (NTRS)

    Horz, F.; Heggy, E.; Fong, T.; Kring, D.; Deans, M.; Anglade, A.; Mahiouz, K.; Bualat, M.; Lee, P.; Bluethmann, W.

    2009-01-01

    Probing radars have been widely recognized by the science community to be an efficient tool to explore lunar subsurface providing a unique capability to address several scientific and operational issues. A wideband (200 to 1200 MHz) Ground Penetrating Radar (GPR) mounted on a surface rover can provide high vertical resolution and probing depth from few tens of centimeters to few tens of meters depending on the sounding frequency and the ground conductivity. This in term can provide a better understand regolith thickness, elemental iron concentration (including ilmenite), volatile presence, structural anomalies and fracturing. All those objectives are of important significance for understanding the local geology and potential sustainable resources for future landing sites in particular exploring the thickness, structural heterogeneity and potential volatiles presence in the lunar regolith. While the operation and data collection of GPR is a straightforward case for most terrestrial surveys, it is a challenging task for remote planetary study especially on robotic platforms due to the complexity of remote operation in rough terrains and the data collection constrains imposed by the mechanical motion of the rover and limitation in data transfer. Nevertheless, Rover mounted GPR can be of great support to perform systematic subsurface surveys for a given landing site as it can provide scientific and operational support in exploring subsurface resources and sample collections which can increase the efficiency of the EVA activities for potential human crews as part of the NASA Constellation Program. In this study we attempt to explore the operational challenges and their impact on the EVA scientific return for operating a rover mounted GPR in support of potential human activity on the moon. In this first field study, we mainly focused on the ability of GPR to support subsurface sample collection and explore shallow subsurface volatiles.

  11. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR USE OF A PASSIVE SAMPLING DEVICE FOR THE COLLECTION OF AIRBORNE VOCS AT FIXED INDOOR AND OUTDOOR SITES (UA-F-12.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the methods used to sample residential indoor and outdoor atmospheres for the presence of certain volatile organic compounds (VOCs) by means of absorption onto activated charcoal contained within a sampling badge. Activated charcoal diffusi...

  12. Exposures to quartz, diesel, dust, and welding fumes during heavy and highway construction.

    PubMed

    Woskie, Susan R; Kalil, Andrew; Bello, Dhimiter; Virji, M Abbas

    2002-01-01

    Personal samples for exposure to dust, diesel exhaust, quartz, and welding fume were collected on heavy and highway construction workers. The respirable, thoracic, and inhalable fractions of dust and quartz exposures were estimated from 260 personal impactor samples. Respirable quartz exposures exceeded the National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit (REL) in 7-31% of cases for the trades sampled. More than 50% of the samples in the installation of drop ceilings and wall tiles and concrete finish operations exceeded the NIOSH REL for quartz. Thoracic exposures to quartz and dust exceeded respirable exposures by a factor of 4.5 and 2.8, respectively. Inhalable exposures to quartz and dust exceeded respirable exposures by a factor of 25.6 and 9.3, respectively. These findings are important due to the identification of quartz as a carcinogen by the National Toxicology Program and the International Agency for Research on Cancer. Fourteen percent of the personal samples for EC (n = 261), collected as a marker for diesel exhaust, exceeded the American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV) for diesel exhaust. Seventeen of the 22 (77%) samples taken during a partially enclosed welding operation reached or exceeded the ACGIH TLV of 5 mg/m3 for welding fume.

  13. Comparison of water-quality samples collected by siphon samplers and automatic samplers in Wisconsin

    USGS Publications Warehouse

    Graczyk, David J.; Robertson, Dale M.; Rose, William J.; Steur, Jeffrey J.

    2000-01-01

    In small streams, flow and water-quality concentrations often change quickly in response to meteorological events. Hydrologists, field technicians, or locally hired stream ob- servers involved in water-data collection are often unable to reach streams quickly enough to observe or measure these rapid changes. Therefore, in hydrologic studies designed to describe changes in water quality, a combination of manual and automated sampling methods have commonly been used manual methods when flow is relatively stable and automated methods when flow is rapidly changing. Auto- mated sampling, which makes use of equipment programmed to collect samples in response to changes in stage and flow of a stream, has been shown to be an effective method of sampling to describe the rapid changes in water quality (Graczyk and others, 1993). Because of the high cost of automated sampling, however, especially for studies examining a large number of sites, alternative methods have been considered for collecting samples during rapidly changing stream conditions. One such method employs the siphon sampler (fig. 1). also referred to as the "single-stage sampler." Siphon samplers are inexpensive to build (about $25- $50 per sampler), operate, and maintain, so they are cost effective to use at a large number of sites. Their ability to collect samples representing the average quality of water passing though the entire cross section of a stream, however, has not been fully demonstrated for many types of stream sites.

  14. Effects of three phosphate industrial sites on ground-water quality in central Florida, 1979 to 1980

    USGS Publications Warehouse

    Miller, R.L.; Sutcliffe, Horace

    1984-01-01

    Geologic, hydrologic, and water quality data and information on test holes collected in the vicinity of gypsum stack complexes at two phosphate chemical plants and one phosphatic clayey waste disposal pond at a phosphate mine and beneficiation plant in central Florida are presented. The data were collected from September 1979 to October 1980 at the AMAX Phosphate, Inc. chemical plant, Piney Point; the USS Agri-Chemicals chemical plant, Bartow; and the International Minerals and Chemical Corporation Clear Springs mine, Bartow. Approximately 5,400 field and laboratory water quality determinations on water samples collected from about 100 test holes and 28 surface-water , 5 rainfall, and other sampling sites at phosphate industry beneficiation and chemical plant waste disposal operations are tabulated. Maps are included to show sampling sites. (USGS)

  15. Water-quality and hydrogeologic data for three phosphate industry waste-disposal sites in central Florida, 1979-80

    USGS Publications Warehouse

    Miller, Ronald L.; Sutcliffe, Horace

    1982-01-01

    This report is a complilation of geologic, hydrologic, and water-quality data and information on test holes collected in the vicinity of gypsum stack complexes at two phosphate chemical plants and one phosphatic clayey waste disposal pond at a phosphate mine and beneficiation plant in central Florida. The data were collected from September 1979 to October 1980 at thee AMAX Phosphate, Inc., chemical plant, Piney Point; the USS AgriChemicals chemical plant, Bartow; and the International Minerals and Chemical Corporation Clear Springs mine, Bartow. Approximmmtely 5,400 field and laboratory water-quality determinations on water samples were collected from about 78 test holes and 31 surface-water, rainfall, and other sampling sites at phosphate industry beneficiation and chemical plant waste-disposal operations. Maps show locations of sampling sites. (USGS)

  16. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR CHAIN-OF-CUSTODY AND SAMPLE TRACKING (G04)

    EPA Science Inventory

    The purpose of the SOP is to establish the normal procedures for ensuring data chain-of-custody and data tracking. The chain-of-custody form included in this SOP is the standard form to be used for all data collected in the field. Keywords: samples; custody; records.

    The Nat...

  17. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FIELD USE OF THE PARTICULATE SAMPLER (UA-F-3.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the in-field use of the particulate sampling system (pumping, control unit, and size selective inlet impactors) for collecting samples of particulate matter from the air during a predetermined time period during the Arizona NHEXAS project an...

  18. Occupational exposure to acrylamide in closed system production plants: air levels and biomonitoring.

    PubMed

    Moorman, William J; Reutman, Susan S; Shaw, Peter B; Blade, Leo Michael; Marlow, David; Vesper, Hubert; Clark, John C; Schrader, Steven M

    2012-01-01

    The aim of this study was to evaluate biomarkers of acrylamide exposure, including hemoglobin adducts and urinary metabolites in acrylamide production workers. Biomarkers are integrated measures of the internal dose, and it is total acrylamide dose from all routes and sources that may present health risks. Workers from three companies were studied. Workers potentially exposed to acrylamide monomer wore personal breathing-zone air samplers. Air samples and surface-wipe samples were collected and analyzed for acrylamide. General-area air samples were collected in chemical processing units and control rooms. Hemoglobin adducts were isolated from ethylenediamine teraacetic acid (EDTA)-whole blood, and adducts of acrylamide and glycidamide, at the N-terminal valines of hemoglobin, were cleaved from the protein chain by use of a modified Edman reaction. Full work-shift, personal breathing zone, and general-area air samples were collected and analyzed for particulate and acrylamide monomer vapor. The highest general-area concentration of acrylamide vapor was 350 μg/cm(3) in monomer production. Personal breathing zone and general-area concentrations of acrylamide vapor were found to be highest in monomer production operations, and lower levels were in the polymer production operations. Adduct levels varied widely among workers, with the highest in workers in the monomer and polymer production areas. The acrylamide adduct range was 15-1884 pmol/g; glycidamide adducts ranged from 17.8 to 1376 p/mol/g. The highest acrylamide and glycidamide adduct levels were found among monomer production process operators. The primary urinary metabolite N-acetyl-S-(2-carbamoylethyl) cysteine (NACEC) ranged from the limit of detection to 15.4 μg/ml. Correlation of workplace exposure and sentinel health effects is needed to determine and control safe levels of exposure for regulatory standards.

  19. Results for the DWPF Slurry Mix Evaporator Condensate Tank, Off Gas Condensate Tank, And Recycle Collection Tank Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    TERRI, FELLINGER

    2004-12-21

    The Defense Waste Processing Facility, DWPF, currently generates approximately 1.4 million gallons of recycle water per year during Sludge-Only operations. DWPF has minimized condensate generation to 1.4 million gallons by not operating the Steam Atomized Scrubbers, SASs, for the melter off gas system. By not operating the SASs, DWPF has reduced the total volume by approximately 800,000 gallons of condensate per year. Currently, the recycle stream is sent to back to the Tank Farm and processed through the 2H Evaporator system. To alleviate the load on the 2H Evaporator system, an acid evaporator design is being considered as an alternatemore » processing and/or concentration method for the DWPF recycle stream. In order to support this alternate processing option, the DWPF has requested that the chemical and radionuclide compositions of the Off Gas Condensate Tank, OGCT, Slurry Mix Evaporator Condensate Tank, SMECT, Recycle Collection Tank, RCT, and the Decontamination Waste Treatment Tank, DWTT, be determined as a part of the process development work for the acid evaporator design. Samples have been retrieved from the OGCT, RCT, and SMECT and have been sent to the Savannah River National Laboratory, SRNL for this characterization. The DWTT samples have been recently shipped to SRNL. The results for the DWTT samples will be issued at later date.« less

  20. NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE--COMPENDIUM OF METHOD SUMMARIES FOR COLLECTION AND ANALYSIS OF METALS AND VOCS IN BLOOD AND URINE (CDC-COMPENDIUM)

    EPA Science Inventory

    This compendium includes method summaries provided by the Centers for Disease Control and Prevention/National Center for Environmental Health (CDC/NCEH) for collection and shipping of blood and urine samples for analysis of metals and volatile organic compounds (VOCs). It provide...

  1. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE--COMPENDIUM OF METHOD SUMMARIES FOR COLLECTION AND ANALYSIS OF METALS, PESTICIDE METABOLITES, AND VOCS IN BLOOD AND URINE (CDC-COMPENDIUM)

    EPA Science Inventory

    This compendium includes method summaries provided by the Centers for Disease Control and Prevention/National Center for Environmental Health (CDC/NCEH) for the collection and shipping of blood and urine samples for analysis of metals and volatile organic compounds (VOCs). It pro...

  2. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE--COMPENDIUM OF METHOD SUMMARIES FOR COLLECTION AND ANALYSIS OF METALS, PESTICIDE METABOLITES, AND VOC IN BLOOD AND URINE (CDC-COMPENDIUM)

    EPA Science Inventory

    This compendium includes method summaries provided by the Centers for Disease Control and Prevention/National Center for Environmental Health (CDC/NCEH) for the collection and shipping of blood and urine samples for analysis of metals and volatile organic compounds (VOCs). It pro...

  3. Astromaterials Acquisition and Curation Office (KT) Overview

    NASA Technical Reports Server (NTRS)

    Allen, Carlton

    2014-01-01

    The Astromaterials Acquisition and Curation Office has the unique responsibility to curate NASA's extraterrestrial samples - from past and forthcoming missions - into the indefinite future. Currently, curation includes documentation, preservation, physical security, preparation, and distribution of samples from the Moon, asteroids, comets, the solar wind, and the planet Mars. Each of these sample sets has a unique history and comes from a unique environment. The curation laboratories and procedures developed over 40 years have proven both necessary and sufficient to serve the evolving needs of a worldwide research community. A new generation of sample return missions to destinations across the solar system is being planned and proposed. The curators are developing the tools and techniques to meet the challenges of these new samples. Extraterrestrial samples pose unique curation requirements. These samples were formed and exist under conditions strikingly different from those on the Earth's surface. Terrestrial contamination would destroy much of the scientific significance of extraterrestrial materials. To preserve the research value of these precious samples, contamination must be minimized, understood, and documented. In addition, the samples must be preserved - as far as possible - from physical and chemical alteration. The elaborate curation facilities at JSC were designed and constructed, and have been operated for many years, to keep sample contamination and alteration to a minimum. Currently, JSC curates seven collections of extraterrestrial samples: (a)) Lunar rocks and soils collected by the Apollo astronauts, (b) Meteorites collected on dedicated expeditions to Antarctica, (c) Cosmic dust collected by high-altitude NASA aircraft,t (d) Solar wind atoms collected by the Genesis spacecraft, (e) Comet particles collected by the Stardust spacecraft, (f) Interstellar dust particles collected by the Stardust spacecraft, and (g) Asteroid soil particles collected by the Japan Aerospace Exploration Agency (JAXA) Hayabusa spacecraft Each of these sample sets has a unique history and comes from a unique environment. We have developed specialized laboratories and practices over many years to preserve and protect the samples, not only for current research but for studies that may be carried out in the indefinite future.

  4. Corrective Action Investigation Plan for Corrective Action Unit 428: Area 3 Septic Waste Systems 1 and 5, Tonopah Test Range, Nevada, REVISION 0, march 1999

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ITLV.

    1999-03-01

    The Corrective Action Investigation Plan for Corrective Action Unit 428, Area 3 Septic Waste Systems 1 and 5, has been developed in accordance with the Federal Facility Agreement and Consent Order that was agreed to by the U. S. Department of Energy, Nevada Operations Office; the State of Nevada Division of Environmental Protection; and the U. S. Department of Defense. Corrective Action Unit 428 consists of Corrective Action Sites 03- 05- 002- SW01 and 03- 05- 002- SW05, respectively known as Area 3 Septic Waste System 1 and Septic Waste System 5. This Corrective Action Investigation Plan is used inmore » combination with the Work Plan for Leachfield Corrective Action Units: Nevada Test Site and Tonopah Test Range, Nevada , Rev. 1 (DOE/ NV, 1998c). The Leachfield Work Plan was developed to streamline investigations at leachfield Corrective Action Units by incorporating management, technical, quality assurance, health and safety, public involvement, field sampling, and waste management information common to a set of Corrective Action Units with similar site histories and characteristics into a single document that can be referenced. This Corrective Action Investigation Plan provides investigative details specific to Corrective Action Unit 428. A system of leachfields and associated collection systems was used for wastewater disposal at Area 3 of the Tonopah Test Range until a consolidated sewer system was installed in 1990 to replace the discrete septic waste systems. Operations within various buildings at Area 3 generated sanitary and industrial wastewaters potentially contaminated with contaminants of potential concern and disposed of in septic tanks and leachfields. Corrective Action Unit 428 is composed of two leachfield systems in the northern portion of Area 3. Based on site history collected to support the Data Quality Objectives process, contaminants of potential concern for the site include oil/ diesel range total petroleum hydrocarbons, and Resource Conservation and Recovery Act characteristic volatile organic compounds, semivolatile organic compounds, and metals. A limited number of samples will be analyzed for gamma- emitting radionuclides and isotopic uranium from four of the septic tanks and if radiological field screening levels are exceeded. Additional samples will be analyzed for geotechnical and hydrological properties and a bioassessment may be performed. The technical approach for investigating this Corrective Action Unit consists of the following activities: Perform video surveys of the discharge and outfall lines. Collect samples of material in the septic tanks. Conduct exploratory trenching to locate and inspect subsurface components. Collect subsurface soil samples in areas of the collection system including the septic tanks and outfall end of distribution boxes. Collect subsurface soil samples underlying the leachfield distribution pipes via trenching. Collect surface and near- surface samples near potential locations of the Acid Sewer Outfall if Septic Waste System 5 Leachfield cannot be located. Field screen samples for volatile organic compounds, total petroleum hydrocarbons, and radiological activity. Drill boreholes and collect subsurface soil samples if required. Analyze samples for total volatile organic compounds, total semivolatile organic compounds, total Resource Conservation and Recovery Act metals, and total petroleum hydrocarbons (oil/ diesel range organics). Limited number of samples will be analyzed for gamma- emitting radionuclides and isotopic uranium from particular septic tanks and if radiological field screening levels are exceeded. Collect samples from native soils beneath the distribution system and analyze for geotechnical/ hydrologic parameters. Collect and analyze bioassessment samples at the discretion of the Site Supervisor if total petroleum hydrocarbons exceed field- screening levels.« less

  5. Impacts of effluent from Carlsbad Desalination Plant on the coastal biology and chemistry in a in-situ study of pre- and post-discharge

    NASA Astrophysics Data System (ADS)

    Petersen, K. L.; Heck, N.; Paytan, A.; Potts, D. C.

    2016-12-01

    Ongoing droughts throughout the world and increasing water demand are creating critical water shortage in arid and semi-arid regions. Desalination of seawater is a powerful source of potable water, however the effects of the brine discharge on coastal areas are insufficiently studied. Here we report results from in-situ measurements of the effects of brine discharge from a desalination plant in Carlsbad, in Southern California before and after operation began. Operation as of December 2015. Pre-discharge samples were collected in December 2014 and September 2015. Post-discharge samples were collected in May 2016 and November 2016. Water samples are collected at the mount of the discharge channel and out to 1000 m offshore. Both surface and bottom water samples were collected and analyzed for salinity, temperature, Chl a concentration, nutrients (NO3, PO4 and silica), δ13C and δ15N of suspended matter, DOC and organic contaminants. Samples are also collected for phytoplankton cell count and sediment grain size. A biological swath was done by SCUBA divers to verify abundance and diversity of benthic organisms. The pre-discharge measurements show a homogenous water column for salinity, Chl a and nutrients. There is a slight temperature difference between the discharge channel and the intake channel due to activities of a power plant around the discharge channel. There are significantly fewer species and a lower abundance of benthic organism by the discharge channel than by the intake. This is possibly due to a higher flow rate at the discharge channel. The preliminary post-discharge analyses show a stratified water column at the discharge area. The salinity was higher by 2 to 3 salinity units at the discharge site. This trend is evident to 600 m offshore. How this affects the benthic organisms and the phytoplankton will be reported.

  6. A novel atmospheric tritium sampling system

    NASA Astrophysics Data System (ADS)

    Qin, Lailai; Xia, Zhenghai; Gu, Shaozhong; Zhang, Dongxun; Bao, Guangliang; Han, Xingbo; Ma, Yuhua; Deng, Ke; Liu, Jiayu; Zhang, Qin; Ma, Zhaowei; Yang, Guo; Liu, Wei; Liu, Guimin

    2018-06-01

    The health hazard of tritium is related to its chemical form. Sampling different chemical forms of tritium simultaneously becomes significant. Here a novel atmospheric tritium sampling system (TS-212) was developed to collect the tritiated water (HTO), tritiated hydrogen (HT) and tritiated methane (CH3T) simultaneously. It consisted of an air inlet system, three parallel connected sampling channels, a hydrogen supply module, a methane supply module and a remote control system. It worked at air flow rate of 1 L/min to 5 L/min, with temperature of catalyst furnace at 200 °C for HT sampling and 400 °C for CH3T sampling. Conversion rates of both HT and CH3T to HTO were larger than 99%. The collecting efficiency of the two-stage trap sets for HTO was larger than 96% in 12 h working-time without being blocked. Therefore, the collected efficiencies of TS-212 are larger than 95% for tritium with different chemical forms in environment. Besides, the remote control system made sampling more intelligent, reducing the operator's work intensity. Based on the performance parameters described above, the TS-212 can be used to sample atmospheric tritium in different chemical forms.

  7. Dynamic Sampling of Trace Contaminants During the Mission Operations Test of the Deep Space Habitat

    NASA Technical Reports Server (NTRS)

    Monje, Oscar; Valling, Simo; Cornish, Jim

    2013-01-01

    The atmospheric composition inside spacecraft during long duration space missions is dynamic due to changes in the living and working environment of crew members, crew metabolism and payload operations. A portable FTIR gas analyzer was used to monitor the atmospheric composition within the Deep Space Habitat (DSH) during the Mission Operations Test (MOT) conducted at the Johnson Space Center (JSC). The FTIR monitored up to 20 gases in near- real time. The procedures developed for operating the FTIR were successful and data was collected with the FTIR at 5 minute intervals. Not all the 20 gases sampled were detected in all the modules and it was possible to measure dynamic changes in trace contaminant concentrations that were related to crew activities involving exercise and meal preparation.

  8. Bringing Home a Piece of Mars from the Utah Desert: A Canadian Robotic Deployment in Support of Mars Sample Return

    NASA Astrophysics Data System (ADS)

    Haltigin, T.; Hipkin, V.; Picard, M.

    2016-12-01

    Mars Sample Return (MSR) remains one of the highest priorities of the international planetary science community. While the overall mission architecture required for MSR is relatively well defined, there remain a number of open questions regarding its implementation. In preparing for an eventual MSR campaign, simulating portions of the sample collection mission can provide important insight to address existing knowledge gaps. In 2015 and 2016, the Canadian Space Agency (CSA) led robotic deployments to address a variety of technical, scientific, operational, and educational objectives. Here we report on the results. The deployments were conducted at a field site near Hanskville, UT, USA, chosen to satisfy scientific, technical, and logistical considerations. The geology of the region is dominated by Jurassic-aged sandstones and mudstones, indicative of an ancient sedimentary environment. Moreover, a series of linear topographically inverted features are present, similar to morphologies observed in particular Martian landscapes. On both Earth and Mars, these features are interpreted as lithified and exhumed river channels. A science operations center was established in London, ON, Canada, at Western University. Here, a science team of > 30 students and professionals - unaware of the rover's actual location - were responsible for generating daily science plans, requesting observations, and interpreting downloaded data, all while respecting Mars-realistic flight rules and constraints for power, scheduling, and data. Rover commanding was performed by an engineering team at CSA headquarters in St. Hubert, QC, Canada, while a small out-of-simulation field team was present on-site to ensure safe operations of the rover and to provide data transfers. Between the 2015 and 2016 campaigns, nearly five weeks of operations were conducted. The team successfully collected scientifically-selected samples to address the group objectives, and the rover demonstrated system integration and a variety of navigational techniques. Forward work involves laboratory-based validation of the returned samples to evaluate the efficiency of the in-simulation operational decision-making.

  9. Evaluation of Sampling Methods for Bacillus Spore ...

    EPA Pesticide Factsheets

    Journal Article Following a wide area release of biological materials, mapping the extent of contamination is essential for orderly response and decontamination operations. HVAC filters process large volumes of air and therefore collect highly representative particulate samples in buildings. HVAC filter extraction may have great utility in rapidly estimating the extent of building contamination following a large-scale incident. However, until now, no studies have been conducted comparing the two most appropriate sampling approaches for HVAC filter materials: direct extraction and vacuum-based sampling.

  10. Explosive vapor detection payload for small robots

    NASA Astrophysics Data System (ADS)

    Stimac, Phil J.; Pettit, Michael; Wetzel, John P.; Haas, John W.

    2013-05-01

    Detection of explosive hazards is a critical component of enabling and improving operational mobility and protection of US Forces. The Autonomous Mine Detection System (AMDS) developed by the US Army RDECOM CERDEC Night Vision and Electronic Sensors Directorate (NVESD) is addressing this challenge for dismounted soldiers. Under the AMDS program, ARA has developed a vapor sampling system that enhances the detection of explosive residues using commercial-off-the-shelf (COTS) sensors. The Explosives Hazard Trace Detection (EHTD) payload is designed for plug-and-play installation and operation on small robotic platforms, addressing critical Army needs for more safely detecting concealed or exposed explosives in areas such as culverts, walls and vehicles. In this paper, we describe the development, robotic integration and performance of the explosive vapor sampling system, which consists of a sampling "head," a vapor transport tube and an extendable "boom." The sampling head and transport tube are integrated with the boom, allowing samples to be collected from targeted surfaces up to 7-ft away from the robotic platform. During sample collection, an IR lamp in the sampling head is used to heat a suspected object/surface and the vapors are drawn through the heated vapor transport tube to an ion mobility spectrometer (IMS) for detection. The EHTD payload is capable of quickly (less than 30 seconds) detecting explosives such as TNT, PETN, and RDX at nanogram levels on common surfaces (brick, concrete, wood, glass, etc.).

  11. Measurements of airborne methylene diphenyl diisocyanate (MDI) concentration in the U.S. workplace.

    PubMed

    Booth, Karroll; Cummings, Barbara; Karoly, William J; Mullins, Sharon; Robert, William P; Spence, Mark; Lichtenberg, Fran W; Banta, J

    2009-04-01

    This article summarizes a large body of industry air sampling data (8134 samples) in which airborne MDI concentrations were measured in a wide variety of manufacturing processes that use either polymeric MDI (PMDI) or monomeric (pure) MDI. Data were collected during the period 1984 through 1999. A total of 606 surveys were conducted for 251 companies at 317 facilities. The database includes 3583 personal (breathing zone) samples and 4551 area samples. Data demonstrate that workplace airborne MDI concentrations are extremely low in a majority of the manufacturing operations. Most (74.6%) of the airborne MDI concentrations measured in the personal samples were nondetectable, i.e., below the limits of quantification (LOQs). A variety of validated industrial hygiene sampling/analytical methods were used for data collection; most are modifications of OSHA Method 47. The LOQs for these methods ranged from 0.1-0.5 microg/sample. The very low vapor pressures of both monomeric MDI and PMDI largely explain the low airborne concentrations found in most operations. However, processes or applications in which the chemical is sprayed or heated may result in higher airborne concentrations and higher exposure potentials if appropriate control measures are not implemented. Data presented in this article will be a useful reference for employers in helping them to manage their health and safety program as it relates to respiratory protection during MDI/PMDI applications.

  12. Decision-theoretic approach to data acquisition for transit operations planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ritchie, S.G.

    The most costly element of transportation planning and modeling activities in the past has usually been that of data acquisition. This is even truer today when the unit costs of data collection are increasing rapidly and at the same time budgets are severely limited by continuing policies of fiscal austerity in the public sector. The overall objectives of this research were to improve the decisions and decision-making capabilities of transit operators or planners in short-range transit planning, and to improve the quality and cost-effectiveness of associated route or corridor-level data collection and service monitoring activities. A new approach was presentedmore » for sequentially updating the parameters of both simple and multiple linear regression models with stochastic regressors, and for determining the expected value of sample information and expected net gain of sampling for associated sample designs. A new approach was also presented for estimating and updating (both spatially and temporally) the parameters of multinomial logit discrete choice models, and for determining associated optimal sample designs for attribute-based and choice-based sampling methods. The approach provides an effective framework for addressing the issue of optimal sampling method and sample size, which to date have been largely unresolved. The application of these methodologies and the feasibility of the decision-theoretic approach was illustrated with a hypothetical case study example.« less

  13. Environmental DNA sampling protocol - filtering water to capture DNA from aquatic organisms

    USGS Publications Warehouse

    Laramie, Matthew B.; Pilliod, David S.; Goldberg, Caren S.; Strickler, Katherine M.

    2015-09-29

    Environmental DNA (eDNA) analysis is an effective method of determining the presence of aquatic organisms such as fish, amphibians, and other taxa. This publication is meant to guide researchers and managers in the collection, concentration, and preservation of eDNA samples from lentic and lotic systems. A sampling workflow diagram and three sampling protocols are included as well as a list of suggested supplies. Protocols include filter and pump assembly using: (1) a hand-driven vacuum pump, ideal for sample collection in remote sampling locations where no electricity is available and when equipment weight is a primary concern; (2) a peristaltic pump powered by a rechargeable battery-operated driver/drill, suitable for remote sampling locations when weight consideration is less of a concern; (3) a 120-volt alternating current (AC) powered peristaltic pump suitable for any location where 120-volt AC power is accessible, or for roadside sampling locations. Images and detailed descriptions are provided for each step in the sampling and preservation process.

  14. Evaluation of a sticky trap for collecting Aedes (Stegomyia) adults in a dengue-endemic area in Thailand.

    PubMed

    Facchinelli, Luca; Koenraadt, Constantianus J M; Fanello, Caterina; Kijchalao, Udom; Valerio, Laura; Jones, James W; Scott, Thomas W; della Torre, Alessandra

    2008-06-01

    Development of new operational techniques for collection and monitoring of adult Stegomyia mosquitoes is considered a pressing need for surveillance and prevention of arboviruses. Here we report the results from a trial carried out in 2 dengue-endemic villages in Thailand to compare the ability to collect Aedes adults of a sticky trap versus a CDC backpack aspirator, which has been used routinely at the study area for entomological/epidemiological surveys. Our comparison was based on a comparable sampling effort required to carry out collections with 2 approaches. Over 19,000 specimens were collected, approximately 90% of which were Culex spp. Sticky traps collected significantly more Aedes aegypti and Aedes albopictus females than did backpack aspirators when located outdoors. The percentage of positive sticky-trap catches was double for Ae. aegypti and almost 20 times higher for Ae. albopictus. Operational benefits of the sticky trap are discussed within the context of the results obtained.

  15. An automated atmospheric sampling system operating on 747 airliners

    NASA Technical Reports Server (NTRS)

    Perkins, P.; Gustafsson, U. R. C.

    1975-01-01

    An air sampling system that automatically measures the temporal and spatial distribution of selected particulate and gaseous constituents of the atmosphere has been installed on a number of commercial airliners and is collecting data on commercial air routes covering the world. Measurements of constituents related to aircraft engine emissions and other pollutants are made in the upper troposphere and lower stratosphere (6 to 12 km) in support of the Global Air Sampling Program (GASP). Aircraft operated by different airlines sample air at latitudes from the Arctic to Australia. This system includes specialized instrumentation for measuring carbon monoxide, ozone, water vapor, and particulates, a special air inlet probe for sampling outside air, a computerized automatic control, and a data acquisition system. Air constituents and related flight data are tape recorded in flight for later computer processing on the ground.

  16. Geochemical data for stream-sediment, heavy-mineral-concentrate and rock samples collected from the Fortyseven Creek gold-arsenic-antimony-tungsten prospect, southwestern Alaska

    USGS Publications Warehouse

    Gray, John E.; Lee, G.K.; O'Leary, R. M.; Theodorakos, P.M.

    1999-01-01

    In the summer of 1991, we conducted a reconnaissance geochemical survey around the Fortyseven Creek Au-As-Sb-W prospect that is located in the southwestern part of the Sleetmute quadrangle. At that time, this project was a small part of a more comprehensive Alaska Mineral Resource Assessment Program (AMRAP) study of the Sleemute quadrangle. AMRAP studies were conducted by the U.S. Geological Survey (USGS) to fulfill requirements of the Alaska National Interests Lands Conservation Act (Public Law 96-487, 1980) to survey certain federal lands to determine their mineral potential. Although AMRAP is no longer in operation, this study represents a small topical study that was conducted during the Sleetmute quadrangle AMRAP study. The objective of the Fortyseven Creek work was to characterize the geochemistry of samples collected downstream from the Fortyseven Creek prospect, as well as mineralized and altered rock samples collected from the prospect. In this report, we describe the samples collected in 1991, the methods used for the analysis of the samples, and the geochemical data for these samples. The data in this report are also available in digital form on computer diskette in Gray and others (1999). An interpretation of these data appears in Gray and others (1998).

  17. Exposure to Fibres, Crystalline Silica, Silicon Carbide and Sulphur Dioxide in the Norwegian Silicon Carbide Industry

    PubMed Central

    Føreland, S.; Bye, E.; Bakke, B.; Eduard, W.

    2008-01-01

    Objectives: The aim of this study was to assess personal exposure to fibres, crystalline silica, silicon carbide (SiC) and sulphur dioxide in the Norwegian SiC industry. Methods: Approximately 720 fibre samples, 720 respirable dust samples and 1400 total dust samples were collected from randomly chosen workers from the furnace, processing and maintenance departments in all three Norwegian SiC plants. The respirable dust samples were analysed for quartz, cristobalite and non-fibrous SiC content. Approximately 240 sulphur dioxide samples were collected from workers in the furnace department. Results: The sorting operators from all plants, control room and cleaning operators in Plant A and charger, charger/mix and payloader operators in Plant C had a geometric mean (GM) of fibre exposure above the Norwegian occupational exposure limit (OEL) (0.1 fibre cm−3). The cleaner operators in Plant A had the highest GM exposure to respirable quartz (20 μg m−3). The charger/mix operators in Plant C had the highest GM exposure to respirable cristobalite (38 μg m−3) and the refinery crusher operators in Plant A had the highest GM exposure to non-fibrous SiC (0.65 mg m−3). Exposure to the crystalline silica and non-fibrous SiC was generally low and between 0.4 and 2.1% of the measurements exceeded the OELs. The cleaner operators in Plant A had the highest GM exposure to respirable dust (1.3 mg m−3) and total dust (21 mg m−3). GM exposures for respirable dust above the Norwegian SiC industry-specific OEL of 0.5 mg m−3 were also found for refinery crusher operators in all plants and mix, charger, charger/mix and sorting operators in Plant C. Only 4% of the total dust measurements exceeded the OEL for nuisance dust of (10 mg m−3). Exposure to sulphur dioxide was generally low. However, peaks in the range of 10–100 p.p.m. were observed for control room and crane operators in Plants A and B and for charger and charger/mix operators in Plant C. Conclusion: Workers in the SiC industry are exposed to a mixture of several agents including SiC fibres, quartz, cristobalite, non-fibrous SiC and sulphur dioxide. Exposure levels were generally below the current Norwegian OELs; however, high exposure to fibres and respirable dust still occurs in the furnace department. PMID:18550624

  18. 77 FR 37441 - Agency Information Collection Activities; Submission for OMB Review; Comment Request; Diesel...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-21

    ... dust and explosive methane gas are present. Diesel equipment operating in underground coal mines also..., such as cabs or canopies, methane monitors, brakes and lights. Sampling of diesel exhaust emissions is...

  19. Role of fish distribution on estimates of standing crop in a cooling reservoir

    USGS Publications Warehouse

    Barwick, D. Hugh

    1984-01-01

    Estimates of fish standing crop from coves in Keowee Reservoir, South Carolina, were obtained in May and August for 3 consecutive years. Estimates were significantly higher in May than in August for most of the major species of fish collected, suggesting that considerable numbers of fish had migrated from the coves by August. This change in fish distribution may have resulted from the operation of a 2,580-megawatt nuclear power plant which altered reservoir stratification. Because fish distribution is sensitive to conditions of reservoir stratification, and because power plants often alter reservoir stratification, annual cove sampling in August may not be sufficient to produce comparable estimates of fish standing crop on which to assess the impact of power plant operations on fish populations. Comparable estimates of fish standing crop can probably be obtained from cooling reservoirs by collecting annual samples at similar water temperatures and concentrations of dissolved oxygen.

  20. Association Between Farm Machinery Operation and Low Back Disorder in Farmers: A Retrospective Cohort Study.

    PubMed

    Essien, Samuel Kwaku; Bath, Brenna; Koehncke, Niels; Trask, Catherine

    2016-06-01

    The association between whole body vibration (WBV) as measured by annual accumulated use of all-terrain vehicles (ATV)/combine/tractor operation and low back disorders (LBDs) among farmers was investigated. Saskatchewan Farm Injury Cohort Study data was used. Baseline data were collected in 2007 on the three vehicle types and other factors. Follow-up data on LBD symptoms were collected during 2013 resulting in 1149 samples. Adjusted for age, education, and gender, LBDs were associated with tractor operation for 1 to 150 hours/year (Relative Risk [RR] = 1.23, 95%CI 1.05 to 1.44), 151 to 400 hours/year (RR = 1.32, 95%CI 114 to 1.54) and 401+ hours/year (RR = 1.34, 95%CI 1.15 to 1.56). Additionally, hip symptoms were associated with tractor operation. Only unadjusted associations were found in combine and ATV operation. Duration of tractor operation and older age are important predictors of both low back and hip symptoms in farmers.

  1. Development and Flight Testing of an Autonomous Landing Gear Health-Monitoring System

    NASA Technical Reports Server (NTRS)

    Woodard, Stanley E.; Coffey, Neil C.; Gonzalez, Guillermo A.; Taylor, B. Douglas; Brett, Rube R.; Woodman, Keith L.; Weathered, Brenton W.; Rollins, Courtney H.

    2003-01-01

    Development and testing of an adaptable vehicle health-monitoring architecture is presented. The architecture is being developed for a fleet of vehicles. It has three operational levels: one or more remote data acquisition units located throughout the vehicle; a command and control unit located within the vehicle; and, a terminal collection unit to collect analysis results from all vehicles. Each level is capable of performing autonomous analysis with a trained expert system. Communication between all levels is done with wireless radio frequency interfaces. The remote data acquisition unit has an eight channel programmable digital interface that allows the user discretion for choosing type of sensors; number of sensors, sensor sampling rate and sampling duration for each sensor. The architecture provides framework for a tributary analysis. All measurements at the lowest operational level are reduced to provide analysis results necessary to gauge changes from established baselines. These are then collected at the next level to identify any global trends or common features from the prior level. This process is repeated until the results are reduced at the highest operational level. In the framework, only analysis results are forwarded to the next level to reduce telemetry congestion. The system's remote data acquisition hardware and non-analysis software have been flight tested on the NASA Langley B757's main landing gear. The flight tests were performed to validate the following: the wireless radio frequency communication capabilities of the system, the hardware design, command and control; software operation; and, data acquisition, storage and retrieval.

  2. Air monitoring of volatile organic compounds at relevant receptors during hydraulic fracturing operations in Washington County, Pennsylvania.

    PubMed

    Maskrey, Joshua R; Insley, Allison L; Hynds, Erin S; Panko, Julie M

    2016-07-01

    A 3-month air monitoring study was conducted in Washington County, Pennsylvania, at the request of local community members regarding the potential risks resulting from air emissions of pollutants related to hydraulic fracturing operations. Continuous air monitoring for total volatile organic compounds was performed at two sampling sites, including a school and a residence, located within 900 m of a hydraulic fracturing well pad that had been drilled prior to the study. Intermittent 24-hour air samples for 62 individual volatile organic compounds were also collected. The ambient air at both sites was monitored during four distinct periods of unconventional natural gas extraction activity: an inactive period prior to fracturing operations, during fracturing operations, during flaring operations, and during another inactive period after operations. The results of the continuous monitoring during fracturing and flaring sampling periods for total volatile organic compounds were similar to the results obtained during inactive periods. Total volatile organic compound 24-hour average concentrations ranged between 0.16 and 80 ppb during all sampling periods. Several individual volatile compounds were detected in the 24-hour samples, but they were consistent with background atmospheric levels measured previously at nearby sampling sites and in other areas in Washington County. Furthermore, a basic yet conservative screening level evaluation demonstrated that the detected volatile organic compounds were well below health-protective levels. The primary finding of this study was that the operation of a hydraulic fracturing well pad in Washington County did not substantially affect local air concentrations of total and individual volatile organic compounds.

  3. Development of standard operating procedures to obtain longitudinal vaginal specimens from nulliparous rabbits as part of HIV vaccine mucosal immunogenicity studies.

    PubMed

    Gómez Román, Victor Raúl; Vinner, Lasse; Grevstad, Berit; Hansen, Jesper Juhl; Wegmann, Frank; Spetz, Anna-Lena; Fomsgaard, Anders

    2010-12-15

    The New Zealand white rabbit model (Oryctolagus cuniculus) is widely used to test whether HIV vaccine candidates elicit systemic antibody responses; however, its use in mucosal immunology has not been fully exploited due to the difficulty in collecting mucosal specimens longitudinally and reproducibly. Here we describe feasible and non-feasible methods to collect vaginal and nasal specimens from nulliparous rabbits. Non-feasible methods were those resulting in poor reproducibility and considerable animal twitching during sampling, whereas feasible methods resulted in no animal twitching and potential for sampling reproducibility. Standard operating procedures (SOPs) were implemented to collect vaginal swabs yielding total IgA titres ranging from 12,500 to 312,500. Intranasal immunisation with a naked DNA vaccine encoding HIV gp140 elicited HIV envelope-specific IgA detectable in nasal but not in vaginal secretions. Our methods provide an alternative to reliably assess pre- and post-vaccination mucosal antibody titres longitudinally in rabbits as part of mucosal HIV vaccine immunogenicity studies. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE--COMPENDIUM OF METHODS FOR ANALYSIS OF TRACE METALS AND PESTICIDES IN DIETARY SAMPLES USING TOTAL DIET STUDY PROCEDURES (FDA-COMPENDIUM)

    EPA Science Inventory

    This compendium contains seven SOPs developed by Food and Drug Administration (FDA) laboratories for methods of analyzing trace metals in dietary samples collected using Total Diet study procedures. The SOPs include the following: (1) Quality Control for Analysis of NHEXAS Food o...

  5. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION OF FIXED SITE INDOOR AND OUTDOOR FORMALDEHYDE PASSIVE SAMPLES (UA-F-13.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the methods used to sample residential indoor and outdoor atmospheres for the presence of formaldehyde using the PF-1 passive formaldehyde sampler. The PF-1 passive sampler is used as a fixed location monitor to determine time integrated ex...

  6. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks.

    PubMed

    Bernini, Patrizia; Bertini, Ivano; Luchinat, Claudio; Nincheri, Paola; Staderini, Samuele; Turano, Paola

    2011-04-01

    (1)H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0-4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  7. Chemical production in electrocautery smoke by a novel predictive model.

    PubMed

    Wu, Y-C; Tang, C-S; Huang, H-Y; Liu, C-H; Chen, Y-L; Chen, D-R; Lin, Y-W

    2011-01-01

    The hazards of electrocautery smoke have been known for decades. However, few clinical studies have been conducted to analyze the responsible variables of the smoke production. This study collected clinical smoke samples and systematically analyzed all possible factors. Thirty diathermy smoke samples were collected during mastectomy and abdominal cavity operations. Samples were analyzed using a gas chromatographer with a flame ionization detector. Data were applied to construct prediction models for chemical production from electrosurgeries to identify all possible factors that impact chemical production during electrosurgery. Toluene was detected in 27 smoke samples (90%) with concentrations of 0.003-0.463 mg/m(3) and production of 176.0-2,780.0 ng. Ethyl benzene and styrene were identified in very few cases. General linear regression analysis demonstrates that surgery type, patient age, electrocautery duration and imparted coagulation energy explained 67.63% of the variation in toluene production. Surgery type and patient age are known prior to surgery. In terms of risk precaution, the operating team should pay close attention to exposure when certain positive factors of increasing the chemical production are known in advance. Copyright © 2011 S. Karger AG, Basel.

  8. Proximity Operations in Microgravity, a Robotic Solution for Maneuvering about an Asteroid Surface

    NASA Astrophysics Data System (ADS)

    Indyk, Stephen; Scheidt, David; Moses, Kenneth; Perry, Justin; Mike, Krystal

    Asteroids remain some of the most under investigated bodies in the solar system. Addition-ally, there is a distinct lack of directly collected information. This is in part due to complex sampling and motion problems that must be overcome before more detailed missions can be formulated. The chief caveat lies in formulating a technique for precision operation in mi-crogravity. Locomotion, in addition to sample collection, involve forces significantly greater than the gravitational force keeping a robot on the surface. The design of a system that can successfully maneuver over unfamiliar surfaces void of natural anchor points is an incredible challenge. This problem was investigated at Johns Hopkins University Applied Physics Laboratory as part of the 2009 NASA Lunar and Planetary Academy. Examining the problem through a two-dimensional robotic simulation, a swarm robotics approach was applied. In simplest form, this was comprised of three grappling robots and one sampling robot. Connected by tethers, the grappling robots traverse a plane and reposition the sampling robot through tensioning the tethers. This presentation provides information on the design of the robotic system, as well as gait analysis and future considerations for a three dimensional system.

  9. Calibration and data collection protocols for reliable lattice parameter values in electron pair distribution function studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abeykoon, A. M. Milinda; Hu, Hefei; Wu, Lijun

    2015-01-30

    Different protocols for calibrating electron pair distribution function (ePDF) measurements are explored and described for quantitative studies on nanomaterials. It is found that the most accurate approach to determine the camera length is to use a standard calibration sample of Au nanoparticles from the National Institute of Standards and Technology. Different protocols for data collection are also explored, as are possible operational errors, to find the best approaches for accurate data collection for quantitative ePDF studies.

  10. Calibration and data collection protocols for reliable lattice parameter values in electron pair distribution function (ePDF) studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abeykoon, A. M. Milinda; Hu, Hefei; Wu, Lijun

    2015-02-01

    We explore and describe different protocols for calibrating electron pair distribution function (ePDF) measurements for quantitative studies on nano-materials. We find the most accurate approach to determine the camera-length is to use a standard calibration sample of Au nanoparticles from National Institute of Standards and Technology. Different protocols for data collection are also explored, as are possible operational errors, to find the best approaches for accurate data collection for quantitative ePDF studies.

  11. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE--COMPENDIUM OF METHOD SUMMARIES FOR COLLECTION AND ANALYSIS OF METALS, PESTICIDE METABOLITES, AND VOC IN BLOOD AND URINE (CDC-COMPENDIUM)

    EPA Science Inventory

    This compendium includes method summaries provided by the Centers for Disease Control and Prevention/National Center for Environmental Health (CDC/NCEH) for the collection and shipping of blood and urine samples for analysis of metals and volatile organic compounds (VOCs). The pr...

  12. OPERATION SUNBEAM, SHOT SMALL BOY. Project Officer’s Report. Project 2.9. Fallout Collection and Gross Sample Analysis

    DTIC Science & Technology

    1985-09-01

    concepts for large scale radiological defense operations. 2. 212 CP 2 PR0c J 2.1 PLAJWU This project participated in the single shotp A Boy, fired on a...inch diameter by 3 inch high NaI scintilla- tion counter taking sample tubes up to 1-1/4 inches in diameter. -The crystal was mounted on an W type...inch high Nal scin- tillation counter. The crystal -source distance was 8-3/4 inches. Shielding consisted of a lead cylinder 2 inches thick, 7 inches

  13. Bird Surveys at DARHT Before and During Operations: Comparison of Species Abundance and Composition and Trace Element Uptake

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    P. R. Fresquez, D. C. Keller, C. D. Hathcock

    2007-11-30

    The Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility Mitigation Action Plan specifies the comparison of baseline conditions in biotic and abiotic media with those collected after operations have started. Operations at DARHT at Los Alamos National Laboratory started in 2000. In this study, the abundance and composition of birds collected near the DARHT facility from 2003 through 2006 were determined and compared to a preoperational period (1999). In addition, the levels of radionuclides and other inorganic chemicals in birds were compared to regional statistical reference levels (RSRLs). The number and diversity of bird species generally increased over preoperational levels with themore » greatest number of birds (412) and species (46) occurring in 2005. The most common bird species collected regardless of time periods were the chipping sparrow (Spizella passerina), the Virginia's warbler (Vermivora virginiae), the western bluebird (Sialia mexicana), the broad-tailed hummingbird (Selasphorus platycercus), the sage sparrow (Amphispiza belli), and the western tanager (Piranga ludoviciana). Most radionuclides, with the exception of uranium-234 and uranium-238, in (whole body) birds collected after operations began were either not detected or below RSRLs. Uranium-234 and uranium-238 concentrations in a few samples were far below screening levels and do not pose a potential unacceptable dose to the birds. In contrast, many inorganic chemicals, particularly arsenic and silver, in birds collected before and after operations began were in higher concentrations than RSRLs. Because birds (skin plus feathers) collected in the years before operations began contained higher levels of arsenic and silver than RSRLs and because there was no evidence of these metals in soil and sediment directly around the DARHT facility, the elevated levels of these metals in birds during early operations are probably not related to DARHT operations. Arsenic and silver in birds, however, have decreased over time to near background levels in 2007.« less

  14. Collaborative Health and Enforcement Operations on the Quality of Antimalarials and Antibiotics in Southeast Asia

    PubMed Central

    Yong, Yuk Lin; Plançon, Aline; Lau, Yen Hui; Hostetler, Dana M.; Fernández, Facundo M.; Green, Michael D.; Sounvoravong, Sourisak; Nara, Suon; Boravann, Mam; Dumrong, Thitikornkovit; Bangsawan, Nurjaya; Low, Min Yong; Lim, Chin-Chin; Ai, Ruth Lee Choo; Newton, Paul N.

    2015-01-01

    Counterfeit (or falsified) and substandard medicines pose a major public health risk. We describe the findings of Operation Storm I and II conducted in 2008–2009 to combat counterfeit medicines through partnership between national customs, Drug Regulatory Agencies (DRAs), and police in Cambodia, Indonesia, Laos, Myanmar, Singapore, Thailand, and Vietnam. Samples were obtained from seizures and market surveillance by national DRAs. Laboratory analysis using spectroscopic and chromatographic techniques and examination of packaging were performed. Ninety-three suspect antibiotics and 95 antimalarial samples were collected. Of the 93 antibiotics, 29 (31%) had % active pharmaceutical ingredient content (%API) < 85% or > 115% (including one counterfeit). Of the 95 antimalarials, 30 (32%) had %API < 85 > 115% API (including one counterfeit). A significant minority of samples, antimalarials (13%) and antibiotics (15%), were collected in plastic bags with minimal or no labeling. Of 20 ampicillin samples, 13 (65%) contained < 85% API (with one counterfeit containing additional amoxicillin). Of 34 oral artesunate samples, 7 (21%) contained %API out of the 85–115% range. Coordinated and synergistic partnership adopted by the participating countries, International Criminal Police Organization (INTERPOL), World Health Organization (WHO), and laboratories facilitated a platform for discussions and intelligence sharing, helping to improve each participating country's capacity to combat poor-quality medicines. PMID:25897069

  15. Statistical analysis of environmental monitoring data: does a worst case time for monitoring clean rooms exist?

    PubMed

    Cundell, A M; Bean, R; Massimore, L; Maier, C

    1998-01-01

    To determine the relationship between the sampling time of the environmental monitoring, i.e., viable counts, in aseptic filling areas and the microbial count and frequency of alerts for air, surface and personnel microbial monitoring, statistical analyses were conducted on 1) the frequency of alerts versus the time of day for routine environmental sampling conducted in calendar year 1994, and 2) environmental monitoring data collected at 30-minute intervals during routine aseptic filling operations over two separate days in four different clean rooms with multiple shifts and equipment set-ups at a parenteral manufacturing facility. Statistical analyses showed, except for one floor location that had significantly higher number of counts but no alert or action level samplings in the first two hours of operation, there was no relationship between the number of counts and the time of sampling. Further studies over a 30-day period at the floor location showed no relationship between time of sampling and microbial counts. The conclusion reached in the study was that there is no worst case time for environmental monitoring at that facility and that sampling any time during the aseptic filling operation will give a satisfactory measure of the microbial cleanliness in the clean room during the set-up and aseptic filling operation.

  16. Air sampling unit for breath analyzers

    NASA Astrophysics Data System (ADS)

    Szabra, Dariusz; Prokopiuk, Artur; Mikołajczyk, Janusz; Ligor, Tomasz; Buszewski, Bogusław; Bielecki, Zbigniew

    2017-11-01

    The paper presents a portable breath sampling unit (BSU) for human breath analyzers. The developed unit can be used to probe air from the upper airway and alveolar for clinical and science studies. The BSU is able to operate as a patient interface device for most types of breath analyzers. Its main task is to separate and to collect the selected phases of the exhaled air. To monitor the so-called I, II, or III phase and to identify the airflow from the upper and lower parts of the human respiratory system, the unit performs measurements of the exhaled CO2 (ECO2) in the concentration range of 0%-20% (0-150 mm Hg). It can work in both on-line and off-line modes according to American Thoracic Society/European Respiratory Society standards. A Tedlar bag with a volume of 5 dm3 is mounted as a BSU sample container. This volume allows us to collect ca. 1-25 selected breath phases. At the user panel, each step of the unit operation is visualized by LED indicators. This helps us to regulate the natural breathing cycle of the patient. There is also an operator's panel to ensure monitoring and configuration setup of the unit parameters. The operation of the breath sampling unit was preliminarily verified using the gas chromatography/mass spectrometry (GC/MS) laboratory setup. At this setup, volatile organic compounds were extracted by solid phase microextraction. The tests were performed by the comparison of GC/MS signals from both exhaled nitric oxide and isoprene analyses for three breath phases. The functionality of the unit was proven because there was an observed increase in the signal level in the case of the III phase (approximately 40%). The described work made it possible to construct a prototype of a very efficient breath sampling unit dedicated to breath sample analyzers.

  17. Measurement of Area and Personal Breathing Zone Concentrations of Diesel Particulate Matter (DPM) during Oil and Gas Extraction Operations, including Hydraulic Fracturing

    PubMed Central

    Esswein, Eric J.; Alexander-Scott, Marissa; Snawder, John; Breitenstein, Michael

    2018-01-01

    Diesel engines serve many purposes in modern oil and gas extraction activities. Diesel particulate matter (DPM) emitted from diesel engines is a complex aerosol that may cause adverse health effects depending on exposure dose and duration. This study reports on personal breathing zone (PBZ) and area measurements for DPM (expressed as elemental carbon) during oil and gas extraction operations including drilling, completions (which includes hydraulic fracturing) and servicing work. Researchers at the National Institute for Occupational Safety and Health (NIOSH) collected 104 full-shift air samples (49 PBZ and 55 area) in Colorado, North Dakota, Texas, and New Mexico during a four year period from 2008-2012 The arithmetic mean (AM) of the full shift TWA PBZ samples was 10 μg/m3; measurements ranged from 0.1 to 52 μg/m3. The geometric mean (GM) for the PBZ samples was 7 μg/m3. The AM of the TWA area measurements was 17 μg/m3 and ranged from 0.1 to 68 μg/m3. The GM for the area measurements was 9.5 μg/m3. Differences between the GMs of the PBZ samples and area samples were not statistically different (P>0.05). Neither the Occupational Safety and Health Administration (OSHA), NIOSH, nor the American Conference of Governmental Industrial Hygienists (ACGIH) have established occupational exposure limits (OEL) for DPM. However, the State of California, Department of Health Services lists a time-weighted average (TWA) OEL for DPM as elemental carbon (EC) exposure of 20 μg/m3. Five of 49 (10.2%) PBZ TWA measurements exceeded the 20 μg/m3 EC criterion. These measurements were collected on Sandmover and Transfer Belt (T-belt) Operators, Blender and Chemical Truck Operators, and Water Transfer Operators during hydraulic fracturing operations. Recommendations to minimize DPM exposures include elimination (locating diesel-driven pumps away from well sites), substitution, (use of alternative fuels), engineering controls using advanced emissions controls technologies, administrative controls (configuration of well sites), hazard communication and worker training. PMID:29053946

  18. Measurement of area and personal breathing zone concentrations of diesel particulate matter (DPM) during oil and gas extraction operations, including hydraulic fracturing.

    PubMed

    Esswein, Eric J; Alexander-Scott, Marissa; Snawder, John; Breitenstein, Michael

    2018-01-01

    Diesel engines serve many purposes in modern oil and gas extraction activities. Diesel particulate matter (DPM) emitted from diesel engines is a complex aerosol that may cause adverse health effects depending on exposure dose and duration. This study reports on personal breathing zone (PBZ) and area measurements for DPM (expressed as elemental carbon) during oil and gas extraction operations including drilling, completions (which includes hydraulic fracturing), and servicing work. Researchers at the National Institute for Occupational Safety and Health (NIOSH) collected 104 full-shift air samples (49 PBZ and 55 area) in Colorado, North Dakota, Texas, and New Mexico during a four-year period from 2008-2012. The arithmetic mean (AM) of the full shift TWA PBZ samples was 10 µg/m 3 ; measurements ranged from 0.1-52 µg/m 3 . The geometric mean (GM) for the PBZ samples was 7 µg/m 3 . The AM of the TWA area measurements was 17 µg/m 3 and ranged from 0.1-68 µg/m 3 . The GM for the area measurements was 9.5 µg/m 3 . Differences between the GMs of the PBZ samples and area samples were not statistically different (P > 0.05). Neither the Occupational Safety and Health Administration (OSHA), NIOSH, nor the American Conference of Governmental Industrial Hygienists (ACGIH) have established occupational exposure limits (OEL) for DPM. However, the State of California, Department of Health Services lists a time-weighted average (TWA) OEL for DPM as elemental carbon (EC) exposure of 20 µg/m 3 . Five of 49 (10.2%) PBZ TWA measurements exceeded the 20 µg/m 3 EC criterion. These measurements were collected on Sandmover and Transfer Belt (T-belt) Operators, Blender and Chemical Truck Operators, and Water Transfer Operators during hydraulic fracturing operations. Recommendations to minimize DPM exposures include elimination (locating diesel-driven pumps away from well sites), substitution, (use of alternative fuels), engineering controls using advanced emission control technologies, administrative controls (configuration of well sites), hazard communication, and worker training.

  19. A summary of the test procedures and operational details of a Delaware River and an ocean dumping pollution monitoring experiment conducted 28 August 1975

    NASA Technical Reports Server (NTRS)

    Hypes, W. D.; Ohlhorst, C. W.

    1977-01-01

    Two remote sensor evaluation experiments are discussed. One experiment was conducted at the DuPont acid-dump site off the Delaware coast. The second was conducted at an organic waste outfall in the Delaware River. The operational objective of obtaining simultaneous sea truth sampling with remote sensors overpasses was met. Descriptions of the test sites, sensors, sensor platforms, flight lines, sea truth data collected, and operational chronology are presented.

  20. Respirable Crystalline Silica Exposures During Asphalt Pavement Milling at Eleven Highway Construction Sites

    PubMed Central

    Hammond, Duane R.; Shulman, Stanley A.; Echt, Alan S.

    2016-01-01

    Asphalt pavement milling machines use a rotating cutter drum to remove the deteriorated road surface for recycling. The removal of the road surface has the potential to release respirable crystalline silica, to which workers can be exposed. This paper describes an evaluation of respirable crystalline silica exposures to the operator and ground worker from two different half-lane and larger asphalt pavement milling machines that had ventilation dust controls and water-sprays designed and installed by the manufacturers. Manufacturer A completed milling for eleven days at four highway construction sites in Wisconsin, while Manufacturer B completed milling for ten days at seven highway construction sites in Indiana. To evaluate the dust controls, full-shift personal breathing zone air samples were collected from an operator and ground worker during the course of normal employee work activities of asphalt pavement milling at eleven different sites. Forty-two personal breathing zone air samples were collected over 21 days (sampling on an operator and ground worker each day). All samples were below 50 µg/m3 for respirable crystalline silica, the National Institute for Occupational Safety and Health recommended exposure limit. The geometric mean personal breathing zone air sample was 6.2 µg/m3 for the operator and 6.1 µg/m3 for the ground worker for the Manufacturer A milling machine. The geometric mean personal breathing zone air sample was 4.2 µg/m3 for the operator and 9.0 µg/m3 for the ground worker for the Manufacturer B milling machine. In addition, upper 95% confidence limits for the mean exposure for each occupation were well below 50 µg/m3 for both studies. The silica content in the bulk asphalt material being milled ranged from 7% to 23% silica for roads milled by Manufacturer A and from 5% to 12% silica for roads milled by Manufacturer B. The results indicate that engineering controls consisting of ventilation controls in combination with water-sprays are capable of controlling occupational exposures to respirable crystalline silica generated by asphalt pavement milling machines on highway construction sites. PMID:26913983

  1. Respirable crystalline silica exposures during asphalt pavement milling at eleven highway construction sites.

    PubMed

    Hammond, Duane R; Shulman, Stanley A; Echt, Alan S

    2016-07-01

    Asphalt pavement milling machines use a rotating cutter drum to remove the deteriorated road surface for recycling. The removal of the road surface has the potential to release respirable crystalline silica, to which workers can be exposed. This article describes an evaluation of respirable crystalline silica exposures to the operator and ground worker from two different half-lane and larger asphalt pavement milling machines that had ventilation dust controls and water-sprays designed and installed by the manufacturers. Manufacturer A completed milling for 11 days at 4 highway construction sites in Wisconsin, and Manufacturer B completed milling for 10 days at 7 highway construction sites in Indiana. To evaluate the dust controls, full-shift personal breathing zone air samples were collected from an operator and ground worker during the course of normal employee work activities of asphalt pavement milling at 11 different sites. Forty-two personal breathing zone air samples were collected over 21 days (sampling on an operator and ground worker each day). All samples were below 50 µg/m(3) for respirable crystalline silica, the National Institute for Occupational Safety and Health recommended exposure limit. The geometric mean personal breathing zone air sample was 6.2 µg/m(3) for the operator and 6.1 µg/m(3) for the ground worker for the Manufacturer A milling machine. The geometric mean personal breathing zone air sample was 4.2 µg/m(3) for the operator and 9.0 µg/m(3) for the ground worker for the Manufacturer B milling machine. In addition, upper 95% confidence limits for the mean exposure for each occupation were well below 50 µg/m(3) for both studies. The silica content in the bulk asphalt material being milled ranged from 7-23% silica for roads milled by Manufacturer A and from 5-12% silica for roads milled by Manufacturer B. The results indicate that engineering controls consisting of ventilation controls in combination with water-sprays are capable of controlling occupational exposures to respirable crystalline silica generated by asphalt pavement milling machines on highway construction sites.

  2. Microbiota in Exhaled Breath Condensate and the Lung.

    PubMed

    Glendinning, Laura; Wright, Steven; Tennant, Peter; Gill, Andrew C; Collie, David; McLachlan, Gerry

    2017-06-15

    The lung microbiota is commonly sampled using relatively invasive bronchoscopic procedures. Exhaled breath condensate (EBC) collection potentially offers a less invasive alternative for lung microbiota sampling. We compared lung microbiota samples retrieved by protected specimen brushings (PSB) and exhaled breath condensate collection. We also sought to assess whether aerosolized antibiotic treatment would influence the lung microbiota and whether this change could be detected in EBC. EBC was collected from 6 conscious sheep and then from the same anesthetized sheep during mechanical ventilation. Following the latter EBC collection, PSB samples were collected from separate sites within each sheep lung. On the subsequent day, each sheep was then treated with nebulized colistimethate sodium. Two days after nebulization, EBC and PSB samples were again collected. Bacterial DNA was quantified using 16S rRNA gene quantitative PCR. The V2-V3 region of the 16S rRNA gene was amplified by PCR and sequenced using Illumina MiSeq. Quality control and operational taxonomic unit (OTU) clustering were performed with mothur. The EBC samples contained significantly less bacterial DNA than the PSB samples. The EBC samples from anesthetized animals clustered separately by their bacterial community compositions in comparison to the PSB samples, and 37 bacterial OTUs were identified as differentially abundant between the two sample types. Despite only low concentrations of colistin being detected in bronchoalveolar lavage fluid, PSB samples were found to differ by their bacterial compositions before and after colistimethate sodium treatment. Our findings indicate that microbiota in EBC samples and PSB samples are not equivalent. IMPORTANCE Sampling of the lung microbiota usually necessitates performing bronchoscopic procedures that involve a hospital visit for human participants and the use of trained staff. The inconvenience and perceived discomfort of participating in this kind of research may deter healthy volunteers and may not be a safe option for patients with advanced lung disease. This study set out to evaluate a less invasive method for collecting lung microbiota samples by comparing samples taken via protected specimen brushings (PSB) to those taken via exhaled breath condensate (EBC) collection. We found that there was less bacterial DNA in EBC samples compared with that in PSB samples and that there were differences between the bacterial communities in the two sample types. We conclude that while EBC and PSB samples do not produce equivalent microbiota samples, the study of the EBC microbiota may still be of interest. Copyright © 2017 Glendinning et al.

  3. Development and evaluation of a helicopter-borne water-quality monitoring system

    NASA Technical Reports Server (NTRS)

    Wallace, J. W.; Jordan, R. A.; Flynn, J.; Thomas, R. W.

    1978-01-01

    A small, helicopter-borne water-quality monitoring package is being developed by the NASA/EPA using a combination of basic in situ water quality sensors and physical sample collector technology. The package is a lightweight system which can be carried and operated by one person as a passenger in a small helicopter typically available by rental at commercial airports. Real-time measurements are made by suspending the water quality monitoring package with a cable from the hovering helicopter. Designed primarily for use in rapidly assessing hazardous material spills in inland and coastal zone water bodies, the system can survey as many as 20 data stations up to 1.5 kilometers apart in 1 hour. The system provides several channels of sensor data and allows for the addition of future sensors. The system will also collect samples from selected sites with sample collection on command. An EPA Spill Response Team member can easily transport, deploy, and operate the water quality monitoring package to determine the distribution, movement, and concentration of the spilled material in the water body.

  4. Megascopic lithologic studies of coals in the Powder River basin in Wyoming and in adjacent basins in Wyoming and North Dakota

    USGS Publications Warehouse

    Trippi, Michael H.; Stricker, Gary D.; Flores, Romeo M.; Stanton, Ronald W.; Chiehowsky, Lora A.; Moore, Timothy A.

    2010-01-01

    Between 1999 and 2007, the U.S. Geological Survey (USGS) investigated coalbed methane (CBM) resources in the Wyoming portion of the Powder River Basin. The study also included the CBM resources in the North Dakota portion of the Williston Basin of North Dakota and the Wyoming portion of the Green River Basin of Wyoming. This project involved the cooperation of the State Office, Reservoir Management Group (RMG) of the Bureau of Land Management (BLM) in Casper, Wyo., and 16 independent gas operators in the Powder River, Williston, and Green River Basins. The USGS and BLM entered into agreements with these CBM operators to supply samples for the USGS to analyze and provide the RMG with rapid, timely results of total gas desorbed, coal quality, and high-pressure methane adsorption isotherm data. This program resulted in the collection of 963 cored coal samples from 37 core holes. This report presents megascopic lithologic descriptive data collected from canister samples extracted from the 37 wells cored for this project.

  5. Solid sorbent air sampler

    NASA Technical Reports Server (NTRS)

    Galen, T. J. (Inventor)

    1986-01-01

    A fluid sampler for collecting a plurality of discrete samples over separate time intervals is described. The sampler comprises a sample assembly having an inlet and a plurality of discreet sample tubes each of which has inlet and outlet sides. A multiport dual acting valve is provided in the sampler in order to sequentially pass air from the sample inlet into the selected sample tubes. The sample tubes extend longitudinally of the housing and are located about the outer periphery thereof so that upon removal of an enclosure cover, they are readily accessible for operation of the sampler in an analysis mode.

  6. Methods for Monitoring Fish Communities of Buffalo National River and Ozark National Scenic Riverways in the Ozark Plateaus of Arkansas and Missouri: Version 1.0

    USGS Publications Warehouse

    Petersen, James C.; Justus, B.G.; Dodd, H.R.; Bowles, D.E.; Morrison, L.W.; Williams, M.H.; Rowell, G.A.

    2008-01-01

    Buffalo National River located in north-central Arkansas, and Ozark National Scenic Riverways, located in southeastern Missouri, are the two largest units of the National Park Service in the Ozark Plateaus physiographic province. The purpose of this report is to provide a protocol that will be used by the National Park Service to sample fish communities and collect related water-quality, habitat, and stream discharge data of Buffalo National River and Ozark National Scenic Riverways to meet inventory and long-term monitoring objectives. The protocol includes (1) a protocol narrative, (2) several standard operating procedures, and (3) supplemental information helpful for implementation of the protocol. The protocol narrative provides background information about the protocol such as the rationale of why a particular resource or resource issue was selected for monitoring, information concerning the resource or resource issue of interest, a description of how monitoring results will inform management decisions, and a discussion of the linkages between this and other monitoring projects. The standard operating procedures cover preparation, training, reach selection, water-quality sampling, fish community sampling, physical habitat collection, measuring stream discharge, equipment maintenance and storage, data management and analysis, reporting, and protocol revision procedures. Much of the information in the standard operating procedures was gathered from existing protocols of the U.S. Geological Survey National Water Quality Assessment program or other sources. Supplemental information that would be helpful for implementing the protocol is included. This information includes information on fish species known or suspected to occur in the parks, sample sites, sample design, fish species traits, index of biotic integrity metrics, sampling equipment, and field forms.

  7. Levels and distribution of polybrominated diphenyl ethers in soil, sediment and dust samples collected from various electronic waste recycling sites within Guiyu town, southern China.

    PubMed

    Labunska, Iryna; Harrad, Stuart; Santillo, David; Johnston, Paul; Brigden, Kevin

    2013-02-01

    Electronic waste recycling operations in some parts of Asia are conducted using rudimentary techniques which result in workplace and environmental contamination with toxic metals and persistent organic pollutants. This study reports concentrations of 14 polybrominated diphenyl ethers (PBDEs), from tri- to deca-brominated, in 31 samples of soil, sediment, dust or ash collected in the vicinity of e-waste recycling sites in Guiyu (southeast China) which were engaged in common activities such as dismantling, shredding, solder recovery, acid processing and open burning. The concentrations detected in this study far exceed those reported previously in urban soil and sediment and are consistent with or exceed those reported in previous studies around e-waste processing facilities. Some of the highest PBDE concentrations reported to date (e.g. 390 000 ng g (-1) dw (∑ 14 PBDEs)) were found in a sample collected from a site used for open-burning of e-waste, while an average concentration of 220 000 ng g (-1) dw (∑ 14 PBDEs) occurred in sediments impacted by circuit board shredding. A decrease in PBDE concentrations observed with increasing distance from workshops in samples associated with acid processing of wastes provides evidence that such operations are a significant source of PBDEs to the environment. Principal components analysis reveals a complex PBDE congener distribution, suggesting contamination by two or even three commercial formulations consistent with the diverse range of wastes processed.

  8. Self-Collected versus Clinician-Collected Sampling for Chlamydia and Gonorrhea Screening: A Systemic Review and Meta-Analysis

    PubMed Central

    Lunny, Carole; Taylor, Darlene; Hoang, Linda; Wong, Tom; Gilbert, Mark; Lester, Richard; Krajden, Mel; Ogilvie, Gina

    2015-01-01

    Background The increases in STI rates since the late 1990s in Canada have occurred despite widespread primary care and targeted public health programs and in the setting of universal health care. More innovative interventions are required that would eliminate barriers to STI testing such as internet-based or mail-in home and community service testing for patients that are hard to reach, who refuse to go for clinician-based testing, or who decline an examination. Jurisdictions such as New Zealand and some American states currently use self-collected sampling, but without the required evidence to determine whether self-collected specimens are as accurate as clinician-collected specimens in terms of chlamydia and gonorrhea diagnostic accuracy. The objective of the review is to compare self-collected vaginal, urine, pharyngeal and rectal samples to our reference standard - clinician-collected cervical, urethral, pharyngeal and rectal sampling techniques to identify a positive specimen using nucleic acid amplification test assays. Methods The hierarchical summary receiver operating characteristic and the fixed effect models were used to assess the accuracy of comparable specimens that were collected by patients compared to clinicians. Sensitivity and specificity estimates with 95% confidence intervals (CI) were reported as our main outcome measures. Findings We included 21 studies based on over 6100 paired samples. Fourteen included studies examined chlamydia only, 6 compared both gonorrhea and chlamydia separately in the same study, and one examined gonorrhea. The six chlamydia studies comparing self-collection by vaginal swab to a clinician-collected cervical swab had the highest sensitivity (92%, 95% CI 87-95) and specificity (98%, 95% CI 97-99), compared to other specimen-types (urine/urethra or urine/cervix). Six studies compared urine self-samples to urethra clinician-collected samples in males and produced a sensitivity of 88% (95% CI 83-93) and a specificity of 99% (95% CI 0.94-0.99). Taking into account that urine samples may be less sensitive than cervical samples, eight chlamydia studies that compared urine self-collected verses clinician-collected cervical samples had a sensitivity of 87% (95% CI 81-91) and high specificity of 99% (95% CI 0.98-1.00). For gonorrhea testing, self-collected urine samples compared to clinician-collected urethra samples in males produced a sensitivity of 92% (95% CI 83-97) and specificity of 99% (95% CI 0.98-1.00). Conclusion The sensitivity and specificity of vaginal self-collected swabs compared to swabs collected by clinicians supports the use of vaginal swab as the recommended specimen of choice in home-based screening for chlamydia and gonorrhea. Urine samples for gonorrhea collected by men had comparably high sensitivity and specificity, so could be recommended as they can be left at room temperature for several days, allowing for the possibility of mail-in home-based testing. In populations that may not go for testing at all, do not have the option of clinical testing, or who refuse a clinical examination, self-collected screening would be a good alternative. We recommend that guidelines on how to self-collect gonorrhea and chlamydia urine, vaginal, rectal and pharyngeal specimens be published. PMID:26168051

  9. Collecting, Managing, and Visualizing Data during Planetary Surface Exploration

    NASA Astrophysics Data System (ADS)

    Young, K. E.; Graff, T. G.; Bleacher, J. E.; Whelley, P.; Garry, W. B.; Rogers, A. D.; Glotch, T. D.; Coan, D.; Reagan, M.; Evans, C. A.; Garrison, D. H.

    2017-12-01

    While the Apollo lunar surface missions were highly successful in collecting valuable samples to help us understand the history and evolution of the Moon, technological advancements since 1969 point us toward a new generation of planetary surface exploration characterized by large volumes of data being collected and used to inform traverse execution real-time. Specifically, the advent of field portable technologies mean that future planetary explorers will have vast quantities of in situ geochemical and geophysical data that can be used to inform sample collection and curation as well as strategic and tactical decision making that will impact mission planning real-time. The RIS4E SSERVI (Remote, In Situ and Synchrotron Studies for Science and Exploration; Solar System Exploration Research Virtual Institute) team has been working for several years to deploy a variety of in situ instrumentation in relevant analog environments. RIS4E seeks both to determine ideal instrumentation suites for planetary surface exploration as well as to develop a framework for EVA (extravehicular activity) mission planning that incorporates this new generation of technology. Results from the last several field campaigns will be discussed, as will recommendations for how to rapidly mine in situ datasets for tactical and strategic planning. Initial thoughts about autonomy in mining field data will also be presented. The NASA Extreme Environments Mission Operations (NEEMO) missions focus on a combination of Science, Science Operations, and Technology objectives in a planetary analog environment. Recently, the increase of high-fidelity marine science objectives during NEEMO EVAs have led to the ability to evaluate how real-time data collection and visualization can influence tactical and strategic planning for traverse execution and mission planning. Results of the last few NEEMO missions will be discussed in the context of data visualization strategies for real-time operations.

  10. Construction and operation of a 10 cfm (cubic feet per minute) sampling system with a 10:1 dilution ratio for measuring condensable emissions. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steele, W.J.; Williamson, A.D.; McCain, J.D.

    1988-04-01

    The report describes a transportable sampling apparatus designed to sample incineration sources at municipal and hazardous-waste disposal facilities, and to provide non-contaminated samples of condensable materials. The sample gas, at a flow rate of 10 cubic feet per minute (c f/m), passes through a modified Source Assessment Sampling System (SASS) cyclone and is then diluted with clean air at 100 cf/m by a novel, perforated cone assembly. Rapid uniform dilution takes place through the vigorous mixing of the sample and clean air streams in the dilution chamber. The resultant gas, cooled to about atmospheric conditions, is passed through a mixingmore » section that provides a residence time of about 3 seconds. The resulting aerosol particles are collected on a Teflon-coated glass-fiber filter. These solids, along with those collected in the cyclone, are subsequently provided for chemical and biological assay analysis.« less

  11. Clinical evaluation of human papillomavirus detection by careHPV™ test on physician-samples and self-samples using the indicating FTA Elute® card.

    PubMed

    Wang, Shao-Ming; Hu, Shang-Ying; Chen, Feng; Chen, Wen; Zhao, Fang-Hui; Zhang, Yu-Qing; Ma, Xin-Ming; Qiao, You-Lin

    2014-01-01

    To make the clinical evaluation of a solid-state human papillomavirus (HPV) sampling medium in combination with an economical HPV testing method (careHPV™) for cervical cancer screening. 396 women aged 25-65 years were enrolled for cervical cancer screening, and four samples were collected. Two samples were collected by woman themselves, among which one was stored in DCM preservative solution (called "liquid sample") and the other was applied on the Whatman Indicating FTA Elute® card (FTA card). Another two samples were collected by physician and stored in DCM preservative solution and FTA card, respectively. All the samples were detected by careHPV™ test. All the women were administered a colposcopy examination, and biopsies were taken for pathological confirmation if necessary. FTA card demonstrated a comparable sensitivity of detecting high grade Cervical Intraepithelial Neoplasia (CIN) with the liquid sample carrier for self and physician-sampling, but showed a higher specificity than that of liquid sample carrier for self-sampling (FTA vs Liquid: 79.0% vs 71.6%, p=0.02). Generally, the FTA card had a comparable accuracy with that of Liquid-based medium by different sampling operators, with an area under the curve of 0.807 for physician and FTA, 0.781 for physician and Liquid, 0.728 for self and FTA, and 0.733 for self and Liquid (p>0.05). FTA card is a promising sample carrier for cervical cancer screening. With appropriate education programmes and further optimization of the experimental workflow, FTA card based self-collection in combination with centralized careHPV™ testing can help expand the coverage of cervical cancer screening in low-resource areas.

  12. Automated collection and processing of environmental samples

    DOEpatents

    Troyer, Gary L.; McNeece, Susan G.; Brayton, Darryl D.; Panesar, Amardip K.

    1997-01-01

    For monitoring an environmental parameter such as the level of nuclear radiation, at distributed sites, bar coded sample collectors are deployed and their codes are read using a portable data entry unit that also records the time of deployment. The time and collector identity are cross referenced in memory in the portable unit. Similarly, when later recovering the collector for testing, the code is again read and the time of collection is stored as indexed to the sample collector, or to a further bar code, for example as provided on a container for the sample. The identity of the operator can also be encoded and stored. After deploying and/or recovering the sample collectors, the data is transmitted to a base processor. The samples are tested, preferably using a test unit coupled to the base processor, and again the time is recorded. The base processor computes the level of radiation at the site during exposure of the sample collector, using the detected radiation level of the sample, the delay between recovery and testing, the duration of exposure and the half life of the isotopes collected. In one embodiment, an identity code and a site code are optically read by an image grabber coupled to the portable data entry unit.

  13. Thermal probe design for Europa sample acquisition

    NASA Astrophysics Data System (ADS)

    Horne, Mera F.

    2018-01-01

    The planned lander missions to the surface of Europa will access samples from the subsurface of the ice in a search for signs of life. A small thermal drill (probe) is proposed to meet the sample requirement of the Science Definition Team's (SDT) report for the Europa mission. The probe is 2 cm in diameter and 16 cm in length and is designed to access the subsurface to 10 cm deep and to collect five ice samples of 7 cm3 each, approximately. The energy required to penetrate the top 10 cm of ice in a vacuum is 26 Wh, approximately, and to melt 7 cm3 of ice is 1.2 Wh, approximately. The requirement stated in the SDT report of collecting samples from five different sites can be accommodated with repeated use of the same thermal drill. For smaller sample sizes, a smaller probe of 1.0 cm in diameter with the same length of 16 cm could be utilized that would require approximately 6.4 Wh to penetrate the top 10 cm of ice, and 0.02 Wh to collect 0.1 g of sample. The thermal drill has the advantage of simplicity of design and operations and the ability to penetrate ice over a range of densities and hardness while maintaining sample integrity.

  14. Molecular epidemiology biomarkers-Sample collection and processing considerations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holland, Nina T.; Pfleger, Laura; Berger, Eileen

    2005-08-07

    Biomarker studies require processing and storage of numerous biological samples with the goals of obtaining a large amount of information and minimizing future research costs. An efficient study design includes provisions for processing of the original samples, such as cryopreservation, DNA isolation, and preparation of specimens for exposure assessment. Use of standard, two-dimensional and nanobarcodes and customized electronic databases assure efficient management of large sample collections and tracking results of data analyses. Standard operating procedures and quality control plans help to protect sample quality and to assure validity of the biomarker data. Specific state, federal and international regulations are inmore » place regarding research with human samples, governing areas including custody, safety of handling, and transport of human samples. Appropriate informed consent must be obtained from the study subjects prior to sample collection and confidentiality of results maintained. Finally, examples of three biorepositories of different scale (European Cancer Study, National Cancer Institute and School of Public Health Biorepository, University of California, Berkeley) are used to illustrate challenges faced by investigators and the ways to overcome them. New software and biorepository technologies are being developed by many companies that will help to bring biological banking to a new level required by molecular epidemiology of the 21st century.« less

  15. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR USE OF THE ACTIVE VOC SAMPLER FOR THE COLLECTION OF AIRBORNE VOCS AT FIXED INDOOR AND OUTDOOR SITES (UA-F-11.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the methods used to collect indoor and outdoor air samples for the determination of selected volatile organic compounds (VOC's) using a pump to draw air through a Carbotrap Sampler. Volatile organic compounds (VOCs) present in the air are p...

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wells, D.

    The SRS Interim Sanitary Landfill opened in Mid-1992 and operated until 1998 under Domestic Waste Permit No. 025500-1120. Several contaminants have been detected in the groundwater beneath the unit.The well sampling and analyses were conducted in accordance with Procedure 3Q5, Hydrogeologic Data Collection.

  17. Comparative study of the vapor analytes of trinitrotoluene (TNT)

    NASA Astrophysics Data System (ADS)

    Edge, Cindy C.; Gibb, Julie; Dugan, Regina E.

    1998-12-01

    Trinitrotoluene (TNT) is a high explosive used in most antipersonnel and antitank landmines. The Institute for Biological Detection Systems (IBDS) has developed a quantitative vapor delivery system, termed olfactometer, for conducting canine olfactory research. The research is conducted utilizing dynamic conditions, therefore, it is imperative to evaluate the headspace of TNT to ensure consistency with the dynamic generation of vapor. This study quantified the vapor headspace of military- grade TNT utilizing two different vapor generated methodologies, static and dynamic, reflecting differences between field and laboratory environments. Static vapor collection, which closely mimics conditions found during field detection, is defined as vapor collected in an open-air environment at ambient temperature. Dynamic vapor collection incorporates trapping of gases from a high flow vapor generation cell used during olfactometer operation. Analysis of samples collected by the two methodologies was performed by gas chromatography/mass spectrometry and the results provided information with regard to the constituents detected. However, constituent concentration did vary between the sampling methods. This study provides essential information regarding the vapor constituents associated with the TNT sampled using different sampling methods. These differences may be important in determining the detection signature dogs use to recognize TNT.

  18. Atmospheric CO2 Records from Sites in the Main Geophysical Observatory Air Sampling Network (1983 - 1993)

    DOE Data Explorer

    Brounshtein, A. M. [Main Geophysical Observatory, St. Petersburg, Russia; Shaskov, A. A. [Main Geophysical Observatory, St. Petersburg, Russia; Paramonova, N. N. [Main Geophysical Observatory, St. Petersburg, Russia; Privalov, V. I. [Main Geophysical Observatory, St. Petersburg, Russia; Starodubtsev, Y. A. [Main Geophysical Observatory, St. Petersburg, Russia

    1997-01-01

    Air samples were collected from five sites in the Main Geophysical Observatory air sampling network to monitor the atmospheric CO2 from 1983 - 1993. Airwas collected generally four times per month in pairs of 1.5-L stainless steel electropolished flasks with one greaseless stainless steel stopcock. Sampling was performed by opening the stopcock of the flasks, which have been evacuated at the central laboratory at the Main Geophysical Observatory (MGO). The air was not dried during sample collection. Attempts were made to obtain samples when the wind speed was >5 m/s and the wind direction corresponded to the predetermined "clean air" sector. The period of record at Bering Island is too short to identify any long-term trends in atmospheric CO2 concentrations; however, the yearly mean atmospheric CO2 concentration at Bering Island rose from approximately 346 parts per million by volume (ppmv) in 1986 to 362.6 ppmv in 1993. Measurements from this station are considered indicative of maritime air masses. The period of record at Kotelny Island is too short to identify any long-term trends in atmospheric CO2 concentrations; however, the yearly mean atmospheric CO2 concentration at Kotelny Island rose from 356.08 parts per million by volume (ppmv) in 1988 to 358.8 ppmv in 1993. Because Kotelny Island is the northernmost Russian sampling site, measurements from this site serve as a useful comparison to other northern sites (e.g., Alert, Northwest Territories). In late 1989, air sampling began at the Russian site of Kyzylcha, located in the Republic of Uzbekistan. Unfortunately, the desert site at Kyzylcha has been out of operation since mid-1991 due to financial difficulties in Russia. The annual mean value of 359.02 parts per million by volume (ppmv) for 1990, the lone full year of operation, is higher than measurements from other monitoring programs at this latitude [e.g., Niwot Ridge (354.7 ppmv in 1990) and Tae-ahn Peninsula]. Station "C," an open ocean site, in the North Atlantic, east of Greenland, was established in 1968 and was operated in cooperation with NOAA's National Weather Service through 1973. The Main Geophysical Observatory collected flask samples at the site from January 1983 through October 1990. The yearly mean atmospheric CO concentration at Station "C" rose from 348.15 parts per million by volume (ppmv) in 1985 to 354.33 ppmv in 1989. The period of record at Teriberka Station is too short to identify any long-term trends in atmospheric CO2 concentrations; however, the yearly mean atmospheric CO2 concentration at Teriberka Station rose from 354.8 parts per million by volume (ppmv) in 1989 to 358.7 ppmv in 1993.

  19. The cytotoxic and genetoxic effects of dust and soil samples from E-waste recycling area on L02 cells.

    PubMed

    Wang, Liulin; Hou, Meiling; An, Jing; Zhong, Yufang; Wang, Xuetong; Wang, Yangjun; Wu, Minghong; Bi, Xinhui; Sheng, Guoying; Fu, Jiamo

    2011-10-01

    Electrical and electronic waste (E-waste) has now become the fastest growing solid waste around the world. Primitive recycling operations for E-waste have resulted in severe contamination of toxic metals and organic chemicals in the related areas. In this study, six dust and soil samples collected from E-waste recycling workshops and open-burning sites in Longtang were analyzed to investigate their cytotoxicity and genotoxicity on L02 cells. These six samples were: dust No. 1 collected at the gate of the workshop; dust No. 2 collected from air conditioning compressor dismantling site; dust No. 3 collected from where some motors, wires, and aluminium products since the 1980s were dismantled; soil No. 1 collected at the circuit board acid washing site; soil No. 2 collected from a wire open-burning site; soil No. 3 collected near a fiber open-burning site. At the same time, two control soil samples were collected from farmlands approximately 8 km away from the dismantling workshops. The results showed that all of these samples could inhibit cell proliferation and cause cell membrane lesion, among which dust No. 3 and soil No. 2 had the strongest toxicity. Moreover, the comet assay showed that the dust No. 3 had the most significant capability to cause DNA single-strand beaks (SSB), while the road dust (dust No. 1) collected at the gate of the workshop, a relatively farer site, showed the slightest capability to induce DNA SSB. The intracellular reactive oxygen species (ROS) detection showed that ROS level was elevated with the increase of dust and soil samples concentration. Dust No. 3 and soil No. 2 had the highest ROS level, followed by dust No. 2 and 1, soil No. 3 and 1. All of the above results indicated that polluted soil and dust from the E-waste area had cytotoxicity and genotoxicity on L02 cells, the mechanism might involve the increased ROS level and consequent DNA SSB.

  20. Prevalence of Giardia duodenalis assemblages in weaned cattle on cow-calf operations in the United States.

    PubMed

    Santin, Monica; Dargatz, David; Fayer, Ronald

    2012-02-10

    To determine the prevalence of Giardia duodenalis in weaned beef calves on cow-calf operations in the United States, fecal specimens were collected from 819 calves (6-18 months of age) from 49 operations. After cleaning and concentration procedures to maximize recovery of cysts from feces, DNA was extracted from each of the 819 specimens. The presence of G. duodenalis was determined by nested PCR of a fragment of the SSU rRNA gene. All positive PCR products were subjected to sequence analysis. The overall sample level prevalence of Giardia was 33.5% with prevalence ranging from 0 to 100% among operations. The highest within herd prevalence of infected beef calves was found in one cow-calf operation from the South region (100%), followed by a cow-calf operation from the West region (90%), and three cow-calf operations from the Midwest region (87.5, 85, and 85%). Giardia was not detected in samples from 7 operations including 5 cow-calf operations from the South region, and 1 cow-calf operation each from the Midwest and West regions. Molecular analysis of the Giardia-positive samples identified assemblage E (or E-like) in 31.7% of all samples (260/819) and assemblage A in 1.2% (10/819). A mixed infection with assemblages A and E was observed in four calves from an operation in Midwest region. The potentially zoonotic assemblage A was detected in specimens from four operations in Midwest region. These findings indicate that most G. duodenalis found in weaned beef calves was assemblage E which represents no known zoonotic threat. However, the presence of assemblage A in a small number of animals poses a potential risk of infection to humans. Published by Elsevier B.V.

  1. Operations Research Flight Ground Service Education/Outreach

    NASA Technical Reports Server (NTRS)

    Smith, Scott M.

    2011-01-01

    This viewgraph presentation describes a nutritional biochemistry assessment of astronauts in preflight, in-flight, and post-flight operations. In-flight collections of blood and urine samples from astronauts to test the effects of Vitamin K, Pro K, Vitamin D, Omega-3 Fatty Acids, Iron, and Sodium in spaceflight is shown. A demonstration of a 1-carbon metabolism pathway that determines the existence of enzymes and polymorphisms is also presented.

  2. Comparison of three sampling and analytical methods for the determination of airborne hexavalent chromium.

    PubMed

    Boiano, J M; Wallace, M E; Sieber, W K; Groff, J H; Wang, J; Ashley, K

    2000-08-01

    A field study was conducted with the goal of comparing the performance of three recently developed or modified sampling and analytical methods for the determination of airborne hexavalent chromium (Cr(VI)). The study was carried out in a hard chrome electroplating facility and in a jet engine manufacturing facility where airborne Cr(VI) was expected to be present. The analytical methods evaluated included two laboratory-based procedures (OSHA Method ID-215 and NIOSH Method 7605) and a field-portable method (NIOSH Method 7703). These three methods employ an identical sampling methodology: collection of Cr(VI)-containing aerosol on a polyvinyl chloride (PVC) filter housed in a sampling cassette, which is connected to a personal sampling pump calibrated at an appropriate flow rate. The basis of the analytical methods for all three methods involves extraction of the PVC filter in alkaline buffer solution, chemical isolation of the Cr(VI) ion, complexation of the Cr(VI) ion with 1,5-diphenylcarbazide, and spectrometric measurement of the violet chromium diphenylcarbazone complex at 540 nm. However, there are notable specific differences within the sample preparation procedures used in three methods. To assess the comparability of the three measurement protocols, a total of 20 side-by-side air samples were collected, equally divided between a chromic acid electroplating operation and a spray paint operation where water soluble forms of Cr(VI) were used. A range of Cr(VI) concentrations from 0.6 to 960 microg m(-3), with Cr(VI) mass loadings ranging from 0.4 to 32 microg, was measured at the two operations. The equivalence of the means of the log-transformed Cr(VI) concentrations obtained from the different analytical methods was compared. Based on analysis of variance (ANOVA) results, no statistically significant differences were observed between mean values measured using each of the three methods. Small but statistically significant differences were observed between results obtained from performance evaluation samples for the NIOSH field method and the OSHA laboratory method.

  3. Annual radiological environmental operating report, Browns Ferry Nuclear Plant, 1987

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1988-04-01

    This report describes the environmental radiological monitoring programs conducted by TVA in the vicinity of Browns Ferry Nuclear Plant in 1987. The program includes the collection of samples from the environment and the determination of the concentrations of radioactive materials in the samples. Samples are taken from stations in the general area of the plant and from areas not influenced by plant operations. Station locations are selected after careful consideration of the weather patterns and projected radiation doses to the various areas around the plant. Material sampled includes air, water, milk, foods, vegetation, soil, fish, sediment, and direct radiation levels.more » Results from stations near the plant are compared with concentrations from control stations and with preoperational measurements to determine potential impacts of plant operations. The vast majority of the exposures calculated from environmental samples were contributed by naturally occurring radioactive materials or from materials commonly found in the environment as a result of atmospheric nuclear weapons fallout. Small amounts of Co-60 were found in sediment samples downstreams from the plant. This activity in stream sediment would result in no measurable increase over background in the dose to the general public. 3 refs., 2 figs., 34 tabs.« less

  4. Browns Ferry Nuclear Plant annual radiological environmental operating report, 1990

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1991-04-01

    This report describes the environmental radiological monitoring program conducted by TVA in the vicinity of Browns Ferry Nuclear Plant in 1990. The program includes the collection of samples from the environment and the determination of the concentrations of radioactive materials in the samples. Samples are taken from stations in the general area of the plant and from areas not influenced by plant operations. Station locations are selected after careful consideration of the weather patterns and projected radiation doses to the various areas around the plant. Material sampled includes air, water, milk, foods, vegetation, soil, fish, sediment, and direct radiation levels.more » Results from stations near the plant are compared with concentrations from control stations and with preoperational measurements to determine potential impacts of plant operations. The vast majority of the exposures calculated from environmental samples were contributed by naturally occurring radioactive materials or from materials commonly found in the environment as a result of atmospheric nuclear weapons fallout. Small amounts of Co-60 were found in sediment samples downstream from the plant. This activity in stream sediment would result in no measurable increase over background in the dose to the general public. 4 refs., 2 figs., 2 tabs.« less

  5. Annual radiological environmental operating report, Browns Ferry Nuclear Plant, 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1990-04-01

    This report describes the environmental radiological monitoring program conducted by TVA in the vicinity of Browns Ferry Nuclear Plant (BFN) in 1989. The program includes the collection of samples from the environment and the determination of the concentrations of radioactive materials in the samples. Samples are taken from stations in the general area of the plant and from areas not influenced by plant operations. Station locations are selected after careful consideration of the weather patterns and projected radiation doses to the various areas around the plant. Material sampled includes air, water, milk, foods, vegetation, soil, fish, sediment, and direct radiationmore » levels. Results from stations near the plant are compared with concentrations from control stations and with preoperational measurements to determine potential impacts if plant operations. The vast majority of the exposures calculated from environmental samples were contributed by naturally occurring radioactive materials or from materials commonly found in the environment as a result of atmospheric nuclear weapons fallout. Small amounts of Co-60 were found in sediment samples downstream from the plant. This activity in river sediment would result in no measurable increase over background in the dose to the general public. 4 refs., 2 figs., 2 tabs.« less

  6. Annual radiological environmental operating report, Browns Ferry Nuclear Plant, 1988

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1989-04-01

    This report describes the environmental radiological monitoring program conducted by TVA in the vicinity of Browns Ferry Nuclear Plant in 1988. The program includes the collection of samples from the environment and the determination of the concentrations of radioactive materials in the samples. Samples are taken from stations in the general area of the plant and from areas not influenced by plant operations. Station locations are selected after careful consideration of the weather patterns and projected radiation doses to the various areas around the plant. Material sampled includes air, water, milk, foods, vegetation, soil, fish, sediment, and direct radiation levels.more » Results from stations near the plant are compared with concentrations from control stations and with preoperational measurements to determine potential impacts of plant operations. The vast majority of the exposures calculated from environmental samples were contributed by naturally occurring radioactive materials or from materials commonly found in the environment as a result of atmospheric nuclear weapons fallout. Small amounts of Co-60 were found in sediment samples downstream from the plant. This activity in stream sediment would result in no measurable increase over background in the dose to the general public. 3 refs., 2 figs., 2 tabs.« less

  7. The Indigo V Indian Ocean Expedition: a prototype for citizen microbial oceanography

    NASA Astrophysics Data System (ADS)

    Lauro, Federico; Senstius, Jacob; Cullen, Jay; Lauro, Rachelle; Neches, Russell; Grzymski, Joseph

    2014-05-01

    Microbial Oceanography has long been an extremely expensive discipline, requiring ship time for sample collection and thereby economically constraining the number of samples collected. This is especially true for under-sampled water bodies such as the Indian Ocean. Specialised scientific equipment only adds to the costs. Moreover, long term monitoring of microbial communities and large scale modelling of global biogeochemical cycles requires the collection of high-density data both temporally and spatially in a cost-effective way. Thousands of private ocean-going vessels are cruising around the world's oceans every day. We believe that a combination of new technologies, appropriate laboratory protocols and strategic operational partnerships will allow researchers to broaden the scope of participation in basic oceanographic research. This will be achieved by equipping sailing vessels with small, satcom-equipped sampling devices, user-friendly collection techniques and a 'pre-addressed-stamped-envelope' to send in the samples for analysis. We aim to prove that 'bigger' is not necessarily 'better' and the key to greater understanding of the world's oceans is to forge the way to easier and cheaper sample acquisition. The ultimate goal of the Indigo V Expedition is to create a working blue-print for 'citizen microbial oceanography'. We will present the preliminary outcomes of the first Indigo V expedition, from Capetown to Singapore, highlighting the challenges and opportunities of such endeavours.

  8. Rapid DNA analysis for automated processing and interpretation of low DNA content samples.

    PubMed

    Turingan, Rosemary S; Vasantgadkar, Sameer; Palombo, Luke; Hogan, Catherine; Jiang, Hua; Tan, Eugene; Selden, Richard F

    2016-01-01

    Short tandem repeat (STR) analysis of casework samples with low DNA content include those resulting from the transfer of epithelial cells from the skin to an object (e.g., cells on a water bottle, or brim of a cap), blood spatter stains, and small bone and tissue fragments. Low DNA content (LDC) samples are important in a wide range of settings, including disaster response teams to assist in victim identification and family reunification, military operations to identify friend or foe, criminal forensics to identify suspects and exonerate the innocent, and medical examiner and coroner offices to identify missing persons. Processing LDC samples requires experienced laboratory personnel, isolated workstations, and sophisticated equipment, requires transport time, and involves complex procedures. We present a rapid DNA analysis system designed specifically to generate STR profiles from LDC samples in field-forward settings by non-technical operators. By performing STR in the field, close to the site of collection, rapid DNA analysis has the potential to increase throughput and to provide actionable information in real time. A Low DNA Content BioChipSet (LDC BCS) was developed and manufactured by injection molding. It was designed to function in the fully integrated Accelerated Nuclear DNA Equipment (ANDE) instrument previously designed for analysis of buccal swab and other high DNA content samples (Investigative Genet. 4(1):1-15, 2013). The LDC BCS performs efficient DNA purification followed by microfluidic ultrafiltration of the purified DNA, maximizing the quantity of DNA available for subsequent amplification and electrophoretic separation and detection of amplified fragments. The system demonstrates accuracy, precision, resolution, signal strength, and peak height ratios appropriate for casework analysis. The LDC rapid DNA analysis system is effective for the generation of STR profiles from a wide range of sample types. The technology broadens the range of sample types that can be processed and minimizes the time between sample collection, sample processing and analysis, and generation of actionable intelligence. The fully integrated Expert System is capable of interpreting a wide range or sample types and input DNA quantities, allowing samples to be processed and interpreted without a technical operator.

  9. USGS Blind Sample Project: monitoring and evaluating laboratory analytical quality

    USGS Publications Warehouse

    Ludtke, Amy S.; Woodworth, Mark T.

    1997-01-01

    The U.S. Geological Survey (USGS) collects and disseminates information about the Nation's water resources. Surface- and ground-water samples are collected and sent to USGS laboratories for chemical analyses. The laboratories identify and quantify the constituents in the water samples. Random and systematic errors occur during sample handling, chemical analysis, and data processing. Although all errors cannot be eliminated from measurements, the magnitude of their uncertainty can be estimated and tracked over time. Since 1981, the USGS has operated an independent, external, quality-assurance project called the Blind Sample Project (BSP). The purpose of the BSP is to monitor and evaluate the quality of laboratory analytical results through the use of double-blind quality-control (QC) samples. The information provided by the BSP assists the laboratories in detecting and correcting problems in the analytical procedures. The information also can aid laboratory users in estimating the extent that laboratory errors contribute to the overall errors in their environmental data.

  10. Maneuver Strategy for OSIRIS-REx Proximity Operations

    NASA Technical Reports Server (NTRS)

    Wibben, Daniel R.; Williams, Kenneth E.; McAdams, James V.; Antreasian, Peter G.; Leonard, Jason M.; Moreau, Michael C.

    2017-01-01

    The Origins Spectral Interpretation Resource Identification Security Regolith Explorer (OSIRIS-REx) asteroid sample return mission will study and observe asteroid (101955) Bennu (previously known as 1999 RQ36) and subsequently collect and return a sample from the asteroid to Earth for further detailed analysis. After a successful launch in September 2016, the spacecraft will be in cruise phase for two years until arrival at asteroid Bennu in late 2018. At that time, aseries of critical maneuvers will provide an initial characterization of Bennu and the dynamical environment surrounding it, ultimately concluding with a successful capture into orbit about the small asteroid. This paper discusses some of the unique navigation challenges presented by these early operational phases in close proximity to Bennu and shares key observations and results from operational tests that have prepared the operations team and help mitigate the risks posed by these challenges.

  11. Dynamic Sampling of Cabin VOCs during the Mission Operations Test of the Deep Space Habitat

    NASA Technical Reports Server (NTRS)

    Monje, Oscar; Rojdev, Kristina

    2013-01-01

    The atmospheric composition inside spacecraft is dynamic due to changes in crew metabolism and payload operations. A portable FTIR gas analyzer was used to monitor the atmospheric composition of four modules (Core lab, Veggie Plant Atrium, Hygiene module, and Xhab loft) within the Deep Space Habitat '(DSH) during the Mission Operations Test (MOT) conducted at the Johnson Space Center. The FTIR was either physically relocated to a new location or the plumbing was changed so that a different location was monitored. An application composed of 20 gases was used and the FTIR was zeroed using N2 gas every time it was relocated. The procedures developed for operating the FTIR were successful as all data was collected and the FTIR worked during the entire MOT mission. Not all the 20 gases in the application sampled were detected and it was possible to measure dynamic VOC concentrations in each DSH location.

  12. An intelligent algorithm for autonomous scientific sampling with the VALKYRIE cryobot

    NASA Astrophysics Data System (ADS)

    Clark, Evan B.; Bramall, Nathan E.; Christner, Brent; Flesher, Chris; Harman, John; Hogan, Bart; Lavender, Heather; Lelievre, Scott; Moor, Joshua; Siegel, Vickie

    2018-07-01

    The development of algorithms for agile science and autonomous exploration has been pursued in contexts ranging from spacecraft to planetary rovers to unmanned aerial vehicles to autonomous underwater vehicles. In situations where time, mission resources and communications are limited and the future state of the operating environment is unknown, the capability of a vehicle to dynamically respond to changing circumstances without human guidance can substantially improve science return. Such capabilities are difficult to achieve in practice, however, because they require intelligent reasoning to utilize limited resources in an inherently uncertain environment. Here we discuss the development, characterization and field performance of two algorithms for autonomously collecting water samples on VALKYRIE (Very deep Autonomous Laser-powered Kilowatt-class Yo-yoing Robotic Ice Explorer), a glacier-penetrating cryobot deployed to the Matanuska Glacier, Alaska (Mission Control location: 61°42'09.3''N 147°37'23.2''W). We show performance on par with human performance across a wide range of mission morphologies using simulated mission data, and demonstrate the effectiveness of the algorithms at autonomously collecting samples with high relative cell concentration during field operation. The development of such algorithms will help enable autonomous science operations in environments where constant real-time human supervision is impractical, such as penetration of ice sheets on Earth and high-priority planetary science targets like Europa.

  13. ACS sampling system: design, implementation, and performance evaluation

    NASA Astrophysics Data System (ADS)

    Di Marcantonio, Paolo; Cirami, Roberto; Chiozzi, Gianluca

    2004-09-01

    By means of ACS (ALMA Common Software) framework we designed and implemented a sampling system which allows sampling of every Characteristic Component Property with a specific, user-defined, sustained frequency limited only by the hardware. Collected data are sent to various clients (one or more Java plotting widgets, a dedicated GUI or a COTS application) using the ACS/CORBA Notification Channel. The data transport is optimized: samples are cached locally and sent in packets with a lower and user-defined frequency to keep network load under control. Simultaneous sampling of the Properties of different Components is also possible. Together with the design and implementation issues we present the performance of the sampling system evaluated on two different platforms: on a VME based system using VxWorks RTOS (currently adopted by ALMA) and on a PC/104+ embedded platform using Red Hat 9 Linux operating system. The PC/104+ solution offers, as an alternative, a low cost PC compatible hardware environment with free and open operating system.

  14. NASA Biological Specimen Repository

    NASA Technical Reports Server (NTRS)

    McMonigal, K. A.; Pietrzyk, R. A.; Sams, C. F.; Johnson, M. A.

    2010-01-01

    The NASA Biological Specimen Repository (NBSR) was established in 2006 to collect, process, preserve and distribute spaceflight-related biological specimens from long duration ISS astronauts. This repository provides unique opportunities to study longitudinal changes in human physiology spanning may missions. The NBSR collects blood and urine samples from all participating ISS crewmembers who have provided informed consent. These biological samples are collected once before flight, during flight scheduled on flight days 15, 30, 60, 120 and within 2 weeks of landing. Postflight sessions are conducted 3 and 30 days after landing. The number of in-flight sessions is dependent on the duration of the mission. Specimens are maintained under optimal storage conditions in a manner that will maximize their integrity and viability for future research The repository operates under the authority of the NASA/JSC Committee for the Protection of Human Subjects to support scientific discovery that contributes to our fundamental knowledge in the area of human physiological changes and adaptation to a microgravity environment. The NBSR will institute guidelines for the solicitation, review and sample distribution process through establishment of the NBSR Advisory Board. The Advisory Board will be composed of representatives of all participating space agencies to evaluate each request from investigators for use of the samples. This process will be consistent with ethical principles, protection of crewmember confidentiality, prevailing laws and regulations, intellectual property policies, and consent form language. Operations supporting the NBSR are scheduled to continue until the end of U.S. presence on the ISS. Sample distribution is proposed to begin with selections on investigations beginning in 2017. The availability of the NBSR will contribute to the body of knowledge about the diverse factors of spaceflight on human physiology.

  15. LX-10 Explosive Damage Studies

    DTIC Science & Technology

    2015-03-03

    samples were fired from a smooth bore, 18-mm gun against a steel target at various velocities. The resulting debris was NAWCWD TM 8757 4 collected...Management Services. The breach of the gun barrel was designed to operate with either powder or gas-driven actuation. The 18-mm barrel was fired using...from a smooth-bore, 18-mm gun against a steel target at various velocities. The resulting debris is collected and fired in a manometric closed vessel

  16. Trajectory Options for a Potential Mars Mission Combining Orbiting Science, Relay and a Sample Return Rendezvous Demonstration

    NASA Technical Reports Server (NTRS)

    Guinn, Joseph R.; Kerridge, Stuart J.; Wilson, Roby S.

    2012-01-01

    Mars sample return is a major scientific goal of the 2011 US National Research Council Decadal Survey for Planetary Science. Toward achievement of this goal, recent architecture studies have focused on several mission concept options for the 2018/2020 Mars launch opportunities. Mars orbiters play multiple roles in these architectures such as: relay, landing site identification/selection/certification, collection of on-going or new measurements to fill knowledge gaps, and in-orbit collection and transportation of samples from Mars to Earth. This paper reviews orbiter concepts that combine these roles and describes a novel family of relay orbits optimized for surface operations support. Additionally, these roles provide an intersection of objectives for long term NASA science, human exploration, technology development and international collaboration.

  17. Hydrogeologic applications for historical records and images from rock samples collected at the Nevada National Security Site and vicinity, Nye County, Nevada - A supplement to Data Series 297

    USGS Publications Warehouse

    Wood, David B.

    2018-03-14

    Rock samples have been collected, analyzed, and interpreted from drilling and mining operations at the Nevada National Security Site for over one-half of a century. Records containing geologic and hydrologic analyses and interpretations have been compiled into a series of databases. Rock samples have been photographed and thin sections scanned. Records and images are preserved and available for public viewing and downloading at the U.S. Geological Survey ScienceBase, Mercury Core Library and Data Center Web site at https://www.sciencebase.gov/mercury/ and documented in U.S. Geological Survey Data Series 297. Example applications of these data and images are provided in this report.

  18. Statistical analysis of general aviation VG-VGH data

    NASA Technical Reports Server (NTRS)

    Clay, L. E.; Dickey, R. L.; Moran, M. S.; Payauys, K. W.; Severyn, T. P.

    1974-01-01

    To represent the loads spectra of general aviation aircraft operating in the Continental United States, VG and VGH data collected since 1963 in eight operational categories were processed and analyzed. Adequacy of data sample and current operational categories, and parameter distributions required for valid data extrapolation were studied along with envelopes of equal probability of exceeding the normal load factor (n sub z) versus airspeed for gust and maneuver loads and the probability of exceeding current design maneuver, gust, and landing impact n sub z limits. The significant findings are included.

  19. Corrective Action Investigation Plan for Corrective Action Unit 428: Area 3 Septic Waste Systems 1 and 5, Tonopah Test Range, Nevada, REVISION 0, march 1999

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DOE /NV

    1999-03-26

    The Corrective Action Investigation Plan for Corrective Action Unit 428, Area 3 Septic Waste Systems 1 and 5, has been developed in accordance with the Federal Facility Agreement and Consent Order that was agreed to by the U. S. Department of Energy, Nevada Operations Office; the State of Nevada Division of Environmental Protection; and the U. S. Department of Defense. Corrective Action Unit 428 consists of Corrective Action Sites 03- 05- 002- SW01 and 03- 05- 002- SW05, respectively known as Area 3 Septic Waste System 1 and Septic Waste System 5. This Corrective Action Investigation Plan is used inmore » combination with the Work Plan for Leachfield Corrective Action Units: Nevada Test Site and Tonopah Test Range, Nevada , Rev. 1 (DOE/ NV, 1998c). The Leachfield Work Plan was developed to streamline investigations at leachfield Corrective Action Units by incorporating management, technical, quality assurance, health and safety, public involvement, field sampling, and waste management information common to a set of Corrective Action Units with similar site histories and characteristics into a single document that can be referenced. This Corrective Action Investigation Plan provides investigative details specific to Corrective Action Unit 428. A system of leachfields and associated collection systems was used for wastewater disposal at Area 3 of the Tonopah Test Range until a consolidated sewer system was installed in 1990 to replace the discrete septic waste systems. Operations within various buildings at Area 3 generated sanitary and industrial wastewaters potentially contaminated with contaminants of potential concern and disposed of in septic tanks and leachfields. Corrective Action Unit 428 is composed of two leachfield systems in the northern portion of Area 3. Based on site history collected to support the Data Quality Objectives process, contaminants of potential concern for the site include oil/ diesel range total petroleum hydrocarbons, and Resource Conservation and Recovery Act characteristic volatile organic compounds, semivolatile organic compounds, and metals. A limited number of samples will be analyzed for gamma- emitting radionuclides and isotopic uranium from four of the septic tanks and if radiological field screening levels are exceeded. Additional samples will be analyzed for geotechnical and hydrological properties and a bioassessment may be performed. The technical approach for investigating this Corrective Action Unit consists of the following activities: (1) Perform video surveys of the discharge and outfall lines. (2) Collect samples of material in the septic tanks. (3) Conduct exploratory trenching to locate and inspect subsurface components. (4) Collect subsurface soil samples in areas of the collection system including the septic tanks and outfall end of distribution boxes. (5) Collect subsurface soil samples underlying the leachfield distribution pipes via trenching. (6) Collect surface and near- surface samples near potential locations of the Acid Sewer Outfall if Septic Waste System 5 Leachfield cannot be located. (7) Field screen samples for volatile organic compounds, total petroleum hydrocarbons, and radiological activity. (8) Drill boreholes and collect subsurface soil samples if required. (9) Analyze samples for total volatile organic compounds, total semivolatile organic compounds, total Resource Conservation and Recovery Act metals, and total petroleum hydrocarbons (oil/ diesel range organics). Limited number of samples will be analyzed for gamma- emitting radionuclides and isotopic uranium from particular septic tanks and if radiological field screening levels are exceeded. (10) Collect samples from native soils beneath the distribution system and analyze for geotechnical/ hydrologic parameters. (11) Collect and analyze bioassessment samples at the discretion of the Site Supervisor if total petroleum hydrocarbons exceed field- screening levels.« less

  20. Effect of ligustrazine on levels of amino acid neurotransmitters in rat striatum after cerebral ischemia-reperfusion injury.

    PubMed

    Han, Jin; Wan, Hai-Tong; Yang, Jie-Hong; Zhang, Yu-Yan; Ge, Li-Jun; Bie, Xiao-Dong

    2014-01-01

    This study aimed to evaluate the effect of ligustrazine on levels of amino acid transmitters in the extracellular fluid of striatum following cerebral ischemia/reperfusion (I/R) in male Sprague-Dawley rats. A microdialysis cannula guide was implanted into the right striatum. After recovery, animals underwent a sham operation or middle cerebral artery occlusion (MCAO). Those that developed cerebral ischemia after MCAO were randomized to receive propylene glycol salt water and ligustrazine respectively. Striatal fluid samples were collected from all animals at 15-min intervals after treatment and were subjected to HPLC analysis of aspartic acid, glutamic acid, taurine, and γ-amino butyric acid. Upon the last sample collection, animals were sacrificed and brain tissue specimens were collected for triphenyltetrazolium chloride staining and NeuN staining. Compared with the sham operation, MCAO induced significant neurological deficits and increased striatal concentrations of the four neurotransmitters assessed in a time-dependent manner (P < 0.01). Ligustrazine effectively attenuated the detrimental effects of MCAO on the brain. These observations suggest that ligustrazine as a novel cerebral infarction-protective agent may have potential clinical implications for I/R-related brain damage.

  1. Air quality during demolition and recovery activities in post-Katrina New Orleans.

    PubMed

    Ravikrishna, Raghunathan; Lee, Han-Woong; Mbuligwe, Stephen; Valsaraj, K T; Pardue, John H

    2010-07-01

    Air samples were collected during demolition and cleanup operations in the Lakeview district of New Orleans, Louisiana, USA, in late 2005 during the period immediately after Hurricane Katrina. Three different high-volume air samples were collected around waste collection areas that were created to temporarily hold the debris from the cleanup of residential properties in the area. Particulate concentrations were elevated and included crystalline fibers associated with asbestos. Metal concentrations on particulate matter resembled those measured in sediments deposited by floodwaters with the exception of Ba, which was elevated at all three locations. The highest organic contaminant concentration measured on particulates was the pesticide Ziram (Zinc, bis[diethylcarbamodithioato-S,S']-, [T-4]-) at 2,200 microg/g of particulate matter during sampling period 2. Ziram is used in latex paint, adhesives, caulking, and wallboard as a preservative. Fungal isolates developed from particulate air samples included species associated with disease including Aspergillus and Penicillium species. These data represent the most comprehensive assessment of demolition activities during the period immediately after Hurricane Katrina. Copyright (c) 2010 SETAC.

  2. Hotel Clinic-Based Diarrheal and Respiratory Disease Surveillance in U.S. Service Members Participating in Operation Bright Star in Egypt, 2009

    PubMed Central

    Sebeny, Peter J.; Nakhla, Isabelle; Moustafa, Manal; Bruton, Jody A.; Cline, Joanne; Hawk, Douglas; El-Mohammady, Hanan; Nada, Rania A.; Ahmed, Salwa F.; Pimentel, Guillermo; Young, Sylvia Y. N.

    2012-01-01

    We conducted clinic-based, influenza-like illness and diarrheal disease surveillance among U.S. service members participating in Operation Bright Star 2009. Epidemiologic data and samples were collected. Nasopharyngeal swab specimens were tested for viruses, and feces was tested for microbiologic, immunologic, and molecular diagnostics. A survey was used to collect self-reported data. From 1,529 surveys, 41% reported diarrheal disease and 25% reported respiratory illness (incidence rate = 62 of 100 versus 37 of 100 person-months; incidence rate ratio = 1.7, 95% confidence interval = 1.5–1.9). Enterotoxigenic Escherichia coli was identified in 74% (69 of 93) of fecal samples. In the influenza-like illness case series, 17% (9 of 52) were positive for influenza A; all were positive for pandemic (pH1N1) 2009 virus. Rates of decreased work performance reported by patients with diarrhea and influenza-like illness were similar (46% versus 48%; P = 0.8). Diarrheal diseases and respiratory illness remain common among deployed military personnel, with important operational impact. Despite an ongoing influenza pandemic, diarrheal disease incidence was higher than that of respiratory illness. PMID:22855764

  3. Cost Effective, Ultra Sensitive Groundwater Monitoring for Site Remediation and Management: Standard Operating Procedures with QA/QC

    DTIC Science & Technology

    2015-05-01

    in consultation with the site management . 4.0 DATA TYPES AND QUALITY CONTROL A sampling plan must account for the collection, handling, and...GUIDANCE DOCUMENT Cost-Effective, Ultra-Sensitive Groundwater Monitoring for Site Remediation and Management : Standard Operating Procedures...Groundwater Monitoring for Site Remediation and Management 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Halden, R.U., Roll, I.B. 5d

  4. EDRN Standard Operating Procedures (SOP) — EDRN Public Portal

    Cancer.gov

    The NCI’s Early Detection Research Network is developing a number of standard operating procedures for assays, methods, and protocols for collection and processing of biological samples, and other reference materials to assist investigators to conduct experiments in a consistent, reliable manner. These SOPs are established by the investigators of the Early Detection Research Network to maintain constancy throughout the Network. These SOPs represent neither a consensus, nor are the recommendations of NCI.

  5. Blood venous sample collection: Recommendations overview and a checklist to improve quality.

    PubMed

    Giavarina, Davide; Lippi, Giuseppe

    2017-07-01

    The extra-analytical phases of the total testing process have substantial impact on managed care, as well as an inherent high risk of vulnerability to errors which is often greater than that of the analytical phase. The collection of biological samples is a crucial preanalytical activity. Problems or errors occurring shortly before, or soon after, this preanalytical step may impair sample quality and characteristics, or else modify the final results of testing. The standardization of fasting requirements, rest, patient position and psychological state of the patient are therefore crucial for mitigating the impact of preanalytical variability. Moreover, the quality of materials used for collecting specimens, along with their compatibility, can guarantee sample quality and persistence of chemical and physical characteristics of the analytes over time, so safeguarding the reliability of testing. Appropriate techniques and sampling procedures are effective to prevent problems such as hemolysis, undue clotting in the blood tube, draw of insufficient sample volume and modification of analyte concentration. An accurate identification of both patient and blood samples is a key priority as for other healthcare activities. Good laboratory practice and appropriate training of operators, by specifically targeting collection of biological samples, blood in particular, may greatly improve this issue, thus lowering the risk of errors and their adverse clinical consequences. The implementation of a simple and rapid check-list, including verification of blood collection devices, patient preparation and sampling techniques, was found to be effective for enhancing sample quality and reducing some preanalytical errors associated with these procedures. The use of this tool, along with implementation of objective and standardized systems for detecting non-conformities related to unsuitable samples, can be helpful for standardizing preanalytical activities and improving the quality of laboratory diagnostics, ultimately helping to reaffirm a "preanalytical" culture founded on knowledge and real risk perception. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  6. Development of a Novel Method for Temporal Analysis of Airborne Microbial Communities

    NASA Astrophysics Data System (ADS)

    Spring, A.; Domingue, K. D.; Mooney, M. M.; Kerber, T. V.; Lemmer, K. M.; Docherty, K. M.

    2017-12-01

    Microorganisms are ubiquitous in the atmosphere, which serves as an important vector for microbial dispersal to all terrestrial habitats. Very little is known about the mechanisms that control microbial dispersal, because sampling of airborne microbial communities beyond 2 m above the ground is limited. The goal of this study was to construct and test an airborne microbial sampling system to collect sufficient DNA for conducting next generation sequencing and microbial community analyses. The system we designed employs helium-filled helikites as a mechanism for launching samplers to various altitudes. The samplers use a passive collection dish system, weigh under 6 lbs and are operated by remote control from the ground. We conducted several troubleshooting experiments to test sampler functionality. We extracted DNA from sterile collection dish surfaces and examined communities using amplicons of the V4 region of 16S rRNA in bacteria using Illumina Mi-Seq. The results of these experiments demonstrate that the samplers we designed 1) remain decontaminated when closed and collect sufficient microbial biomass for DNA-based analyses when open for 6 hours; 2) are optimally decontaminated with 15 minutes of UV exposure; 3) require 8 collection dish surfaces to collect sufficient biomass. We also determined that DNA extraction conducted within 24 hours of collection has less of an impact on community composition than extraction after frozen storage. Using this sampling system, we collected samples from multiple altitudes in December 2016 and May 2017 at 3 sites in Kalamazoo and Pellston, Michigan. In Kalamazoo, areas sampled were primarily developed or agricultural, while in Pellston they were primarily forested. We observed significant differences between airborne bacterial communities collected at each location and time point. Additionally, bacterial communities did not differ with altitude, suggesting that terrestrial land use has an important influence on the upward distribution of bacteria. Proteobacteria were predominant in air samples from Kalamazoo, while Firmicutes were more prevalent in Pellston. Our results demonstrate that the sampling platform we designed is a useful tool for exploring ecological questions related to distribution of airborne microbial communities across a vertical transect.

  7. Determination of regulatory ionophore coccidiostat residues in feedstuffs at carry-over levels by liquid chromatography-mass spectrometry

    PubMed Central

    Stramenga, Arianna; Colagrande, Maria Novella; Campana, Guido; Scortichini, Giampiero; Migliorati, Giacomo; Compagnone, Dario

    2017-01-01

    In this study samples of feedstuffs were collected from different feed mills and animal farms located in central Italy and analyzed for ionophore coccidiostat residues at carry-over levels by liquid chromatography-mass spectrometry. Since unavoidable cross-contamination of feedstuffs may occur during their production as well as distribution and storage, the collection of samples covered all these different stages. Residues of lasalocid, monensin, salinomycin and maduramicin were detected in 32.4% of samples, both at production and storage level. The maximum content for unavoidable carry-over set by Regulation (EU) No 574/2011 was exceeded in 11.3% of samples. The variability of the results highlighted the different approach of each investigated feed business operator to avoid any cross-contamination in non-target feed. The method developed in this study can be able to detect ionophore coccidiostats at low concentrations consequent to carry-over. PMID:28792977

  8. GICHD mine dog testing project - soil sample results #4.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnett, James L.; Phelan, James M.; Archuleta, Luisa M.

    2003-08-01

    A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan and Bosnia containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performancemore » and seasonal weather conditions. This report documents the analytical chemical methods and results from the fourth batch of soils received. This batch contained samples from Kharga, Afghanistan collected in April 2003 and Sarajevo, Bosnia collected in May 2003.« less

  9. A Multi-Decadal Sample Return Campaign Will Advance Lunar and Solar System Science and Exploration by 2050

    NASA Technical Reports Server (NTRS)

    Neal, C. R.; Lawrence, S. J.

    2017-01-01

    There have been 11 missions to the Moon this century, 10 of which have been orbital, from 5 different space agencies. China became the third country to successfully soft-land on the Moon in 2013, and the second to successfully remotely operate a rover on the lunar surface. We now have significant global datasets that, coupled with the 1990s Clementine and Lunar Prospector missions, show that the sample collection is not representative of the lithologies present on the Moon. The M3 data from the Indian Chandrayaan-1 mission have identified lithologies that are not present/under-represented in the sample collection. LRO datasets show that volcanism could be as young as 100 Ma and that significant felsic complexes exist within the lunar crust. A multi-decadal sample return campaign is the next logical step in advancing our understanding of lunar origin and evolution and Solar System processes.

  10. Use of Electronic Health Records in Residential Care Communities

    MedlinePlus

    ... this stage, and on other aspects of sampling design and data collection, are available elsewhere ( 11 ). Differences among subgroups were ... AJ, Harris-Kojetin LD, Sengupta M, et al. Design and operation of the 2010 National Survey of Residential Care Facilities [PDF 2.10 MB] . ...

  11. CTEPP STANDARD OPERATING PROCEDURE FOR CONDUCTING STAFF AND PARTICIPANT TRAINING (SOP-2.27)

    EPA Science Inventory

    This SOP describes the method to train project staff and participants to collect various field samples and questionnaire data for the study. The training plan consists of two separate components: project staff training and participant training. Before project activities begin,...

  12. 40 CFR 141.804 - Aircraft water system operations and maintenance plan.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... must include the following requirements for procedures for disinfection and flushing of aircraft water system. (i) The air carrier must conduct disinfection and flushing of the aircraft water system in... water procedures; (ii) Sample collection procedures; (iii) Disinfection and flushing procedures; (iv...

  13. An evaluation of remote sensing technologies for the detection of residual contamination at ready-for-anticipated use sites

    USGS Publications Warehouse

    Slonecker, E. Terrence; Fisher, Gary B.

    2014-01-01

    Operational problems with site access and information, XRF instrument operation, and imagery collections hampered the effective data collection and analysis process. Of the 24 sites imaged and analyzed, 17 appeared to be relatively clean with no discernible metal contamination, hydrocarbons, or asbestos in the soil. None of the samples for the sites in Louisiana had any result exceeding the appropriate industrial or residential standard for arsenic or lead. One site in South Carolina (North Street Dump) had two samples that exceeded the residential standard for lead. One site in Texas (Cadiz Street), and four sites in Florida (210 North 12th Street, Encore Retail Site, Clearwater Auto, and 22nd Street Mixed Use) were found to have some level of residual metal contamination above the applicable residential or commercial Risk-Based Concentration (RBC) standard. Three of the Florida sites showing metal contamination also showed a pattern of vegetation stress based on standard vegetation analysis techniques.

  14. Protocol for monitoring metals in Ozark National Scenic Riverways, Missouri: Version 1.0

    USGS Publications Warehouse

    Schmitt, Christopher J.; Brumbaugh, William G.; Besser, John M.; Hinck, Jo Ellen; Bowles, David E.; Morrison, Lloyd W.; Williams, Michael H.

    2008-01-01

    The National Park Service is developing a monitoring plan for the Ozark National Scenic Riverways in southeastern Missouri. Because of concerns about the release of lead, zinc, and other metals from lead-zinc mining to streams, the monitoring plan will include mining-related metals. After considering a variety of alternatives, the plan will consist of measuring the concentrations of cadmium, cobalt, lead, nickel, and zinc in composite samples of crayfish (Orconectes luteus or alternate species) and Asian clam (Corbicula fluminea) collected periodically from selected sites. This document, which comprises a protocol narrative and supporting standard operating procedures, describes the methods to be employed prior to, during, and after collection of the organisms, along with procedures for their chemical analysis and quality assurance; statistical analysis, interpretation, and reporting of the data; and for modifying the protocol narrative and supporting standard operating procedures. A list of supplies and equipment, data forms, and sample labels are also included. An example based on data from a pilot study is presented.

  15. Detection of bacteraemias during non-surgicalroot canal treatment.

    PubMed

    Savarrio, L; Mackenzie, D; Riggio, M; Saunders, W P; Bagg, J

    2005-04-01

    Some dental procedures initiate a bacteraemia. In certain compromised patients, this bacteraemia may lead to distant site infections, most notably infective endocarditis. To investigate whether a detectable bacteraemia was produced during non-surgical root canal therapy. Thirty patients receiving non-surgical root canal therapy were studied. Three blood samples were taken per patient: pre-operatively, peri-operatively and post-operatively. In addition, a paper point sample was collected from the root canal. The blood samples were cultured by pour plate and blood bottle methods. The isolated organisms were identified by standard techniques. Blood samples were analysed for the presence of bacterial DNA by the polymerase chain reaction (PCR). In two cases where the same species of organism was identified in the root canal and the bloodstream, the isolates were typed by pulsed field gel electrophoresis (PFGE). By conventional culturing, a detectable bacteraemia was present in 9 (30%) of the 30 patients who had no positive pre-operative control blood sample. In 7 (23.3%) patients, the same species of organism was identified in both the bloodstream and in the paper point sample from the root canal system. Overall, PCR gave lower detection rates compared with conventional culture, with 10 of 90 (11%) of the blood samples displaying bacterial DNA. PFGE typing was undertaken for two pairs of culture isolates from blood and paper points; these were found to be genetically identical. Non-surgical root canal treatment may invoke a detectable bacteraemia.

  16. Fluorescein: a Photo-CIDNP Sensitizer Enabling Hyper-Sensitive NMR Data Collection in Liquids at Low Micromolar Concentration

    PubMed Central

    Okuno, Yusuke; Cavagnero, Silvia

    2016-01-01

    Photochemically induced dynamic nuclear polarization (photo-CIDNP) is a powerful approach for sensitivity enhancement in NMR spectroscopy. In liquids, inter-molecular photo-CIDNP depends on the transient bimolecular reaction between photoexcited dye and sample of interest. Hence the extent of polarization is sample-concentration dependent. This study introduces fluorescein (FL) as a photo-CIDNP dye whose performance is exquisitely tailored to data collection at extremely low sample concentrations. The photo-CIDNP resonance intensities of tryptophan in the presence of either FL or FMN (i.e., the routinely employed flavin mononucleotide photosensitizer) in the liquid state show that FL yields superior sensitivity and enables rapid data collection down to an unprecedented 1 micromolar concentration. This result was achieved on a conventional spectrometer operating at 14.1 Tesla, and equipped with a room-temperature probe (i.e., non-cryogenic). Kinetic simulations show that the excellent behavior of FL arises from its long excited-state triplet lifetime and superior photostability relative to conventional photo-CIDNP sensitizers. PMID:26744790

  17. Wireless, battery-operated data acquisition system for mobile spectrometry applications and (potentially) for the Internet of things

    NASA Astrophysics Data System (ADS)

    Fitzgerald, Ryan; Karanassios, Vassili

    2017-05-01

    There are many applications requiring chemical analysis in the field and analytical results in (near) real-time. For example, when accidental spills occur. In others, collecting samples in the field followed by analysis in a lab increases costs and introduces time-delays. In such cases, "bring part of the lab to the sample" would be ideal. Toward this ideal (and to further reduce size and weight), we developed a relatively inexpensive, battery-operated, wireless data acquisition hardware system around an Arduino nano micro-controller and a 16-bit ADC (Analog-to- Digital Converter) with a max sampling rate of 860 samples/s. The hardware communicates the acquired data using low-power Bluetooth. Software for data acquisition and data display was written in Python. Potential ways of making the hardware-software approach described here a part of the Internet-of-Things (IoT) are presented.

  18. The planetary spatial data infrastructure for the OSIRIS-REx mission

    NASA Astrophysics Data System (ADS)

    DellaGiustina, D. N.; Selznick, S.; Nolan, M. C.; Enos, H. L.; Lauretta, D. S.

    2017-12-01

    The primary objective of the Origins, Spectral Interpretation, Resource Identification, and Security-Regolith Explorer (OSIRIS-REx) mission is to return a pristine sample of carbonaceous material from primitive asteroid (101955) Bennu. Understanding the geospatial context of Bennu is critical to choosing a sample-site and also linking the nature of the sample to the global properties of Bennu and the broader asteroid population. We established a planetary spatial data infrastructure (PSDI) support the primary objective of OSIRIS-REx. OSIRIS-REx is unique among planetary missions in that all remote sensing is performed to support the sample return objective. Prior to sampling, OSIRIS-REx will survey Bennu for nearly two years to select and document the most valuable primary and backup sample sites. During this period, the mission will combine coordinated observations from five science instruments into four thematic maps: deliverability, safety, sampleability, and scientific value. The deliverability map assesses the probability that the flight dynamics team can deliver the spacecraft to the desired location. The safety map indicates the probability that physical hazards are present at the sample-site. The sampleability map quantifies the probability that a sample can be successfully collected from the surface. Finally, the scientific value map shows the probability that the collected sample contains organics and volatiles and also places the sample site in a definitive geological context relative to Bennu's history. The OSIRIS-REx Science Processing and Operations Center (SPOC) serves as the operational PSDI for the mission. The SPOC is tasked with intake of all data from the spacecraft and other ground sources and assimilating these data into a single comprehensive system for processing and presentation. The SPOC centralizes all geographic data of Bennu in a relational database and ensures that standardization and provenance are maintained throughout proximity operations.The SPOC is a live system that handles inputs from spacecraft and science instrument telemetry, and science data producers. It includes multiple levels of validation, both automated and manual to process all data in a robust and reliable manner and eventually deliver it to the NASA Planetary Data System for archive.

  19. Digital Curation of Marine Physical Samples at Ocean Networks Canada

    NASA Astrophysics Data System (ADS)

    Jenkyns, R.; Tomlin, M. C.; Timmerman, R.

    2015-12-01

    Ocean Networks Canada (ONC) has collected hundreds of geological, biological and fluid samples from the water column and seafloor during its maintenance expeditions. These samples have been collected by Remotely Operated Vehicles (ROVs), divers, networked and autonomously deployed instruments, and rosettes. Subsequent measurements are used for scientific experiments, calibration of in-situ and remote sensors, monitoring of Marine Protected Areas, and environment characterization. Tracking the life cycles of these samples from collection to dissemination of results with all the pertinent documents (e.g., protocols, imagery, reports), metadata (e.g., location, identifiers, purpose, method) and data (e.g., measurements, taxonomic classification) is a challenge. The initial collection of samples is normally documented in SeaScribe (an ROV dive logging tool within ONC's Oceans 2.0 software) for which ONC has defined semantics and syntax. Next, samples are often sent to individual scientists and institutions (e.g., Royal BC Museum) for processing and storage, making acquisition of results and life cycle metadata difficult. Finally, this information needs to be retrieved and collated such that multiple user scenarios can be addressed. ONC aims to improve and extend its digital infrastructure for physical samples to support this complex array of samples, workflows and applications. However, in order to promote effective data discovery and exchange, interoperability and community standards must be an integral part of the design. Thus, integrating recommendations and outcomes of initiatives like the EarthCube iSamples working groups are essential. Use cases, existing tools, schemas and identifiers are reviewed, while remaining gaps and challenges are identified. The current status, selected approaches and possible future directions to enhance ONC's digital infrastructure for each sample type are presented.

  20. Water- and air-quality monitoring of the Sweetwater Reservoir Watershed, San Diego County, California - Phase One results, continued, 2001-2003

    USGS Publications Warehouse

    Mendez, Gregory O.; Foreman, William T.; Morita, Andrew; Majewski, Michael S.

    2008-01-01

    In 1998, the U.S. Geological Survey, in cooperation with the Sweetwater Authority, began a study to monitor water, air, and sediment at the Sweetwater and Loveland Reservoirs in San Diego County, California. The study includes regular sampling of water and air at Sweetwater Reservoir for chemical constituents, including volatile organic compounds (VOC), polynuclear aromatic hydrocarbons (PAH), pesticides, and major and trace elements. The purpose of this study is to monitor changes in contaminant composition and concentration during the construction and operation of State Route 125. To accomplish this, the study was divided into two phases. Phase One sampling (water years 1998–2004) determined baseline conditions for the detection frequency and the concentrations of target compounds in air and water. Phase Two sampling (starting water year 2005) continues at selected monitoring sites during and after construction of State Route 125 to assess the chemical impact this roadway alignment may have on water quality in the reservoir. Water samples were collected for VOCs and pesticides at Loveland Reservoir during Phase One and will be collected during Phase Two for comparison purposes. Air samples collected to monitor changes in VOCs, PAHs, and pesticides were analyzed by adapting methods used to analyze water samples. Bed-sediment samples have been and will be collected three times during the study; at the beginning of Phase One, at the start of Phase Two, and near the end of the study. In addition to the ongoing data collection, several special studies were initiated to assess the occurrence of specific chemicals of concern, such as trace metals, anthropogenic indicator compounds, and pharmaceuticals. This report describes the study design, and the sampling and analytical methods, and presents data from water and air samples collected during the fourth and fifth years of Phase One of the study (October 2001 to September 2003). Data collected during the first three years has been previously published. Three types of quality-control samples were used in this study: blanks, spikes, and replicates. Blanks and spikes are used to estimate result bias, and replicates are used to estimate result variability. Additionally, surrogate compounds were added at the laboratory to samples of VOCs, PAHs, pesticides, anthropogenic indicator compounds, and pharmaceuticals to monitor sample-specific performance of the analytical method.

  1. A high-throughput core sampling device for the evaluation of maize stalk composition

    PubMed Central

    2012-01-01

    Background A major challenge in the identification and development of superior feedstocks for the production of second generation biofuels is the rapid assessment of biomass composition in a large number of samples. Currently, highly accurate and precise robotic analysis systems are available for the evaluation of biomass composition, on a large number of samples, with a variety of pretreatments. However, the lack of an inexpensive and high-throughput process for large scale sampling of biomass resources is still an important limiting factor. Our goal was to develop a simple mechanical maize stalk core sampling device that can be utilized to collect uniform samples of a dimension compatible with robotic processing and analysis, while allowing the collection of hundreds to thousands of samples per day. Results We have developed a core sampling device (CSD) to collect maize stalk samples compatible with robotic processing and analysis. The CSD facilitates the collection of thousands of uniform tissue cores consistent with high-throughput analysis required for breeding, genetics, and production studies. With a single CSD operated by one person with minimal training, more than 1,000 biomass samples were obtained in an eight-hour period. One of the main advantages of using cores is the high level of homogeneity of the samples obtained and the minimal opportunity for sample contamination. In addition, the samples obtained with the CSD can be placed directly into a bath of ice, dry ice, or liquid nitrogen maintaining the composition of the biomass sample for relatively long periods of time. Conclusions The CSD has been demonstrated to successfully produce homogeneous stalk core samples in a repeatable manner with a throughput substantially superior to the currently available sampling methods. Given the variety of maize developmental stages and the diversity of stalk diameter evaluated, it is expected that the CSD will have utility for other bioenergy crops as well. PMID:22548834

  2. Volatile organic compound measurements in the California/Mexico border region during SCOS97

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zielinska, B.; Sagebiel, J.; Uberna, E.

    1999-07-01

    Measurements of volatile organic compounds (VOC) were carried out in the California/Mexico border region during the Southern California Ozone study in the Summer of 1997 (SCOS97). Integrated 3-hr samples were collected in Rosarito (south of Tijuana, Mexico) and in Mexicali during Intensive Operational Periods (IOP), twice per IOP day. VOC were collected using stainless-steel 6 L canisters; carbonyl compounds were collected using 2,4-dinitrophenylhydrazine (DNPH) impregnated C{sub 18} SepPak cartridges. The canister samples were analyzed for speciated volatile hydrocarbons (C{sub 2}-C{sub 12}), CO, CO{sub 2}, CH{sub 4}, MTBE, and halogenated hydrocarbons. DNPH-impregnated cartridges were analyzed for fourteen C{sub 1}-C{sub 7} carbonylmore » compounds. The results of these measurements will be discussed.« less

  3. Adaptive Caching Concept

    NASA Image and Video Library

    2015-06-10

    This diagram, superimposed on a photo of Martian landscape, illustrates a concept called "adaptive caching," which is in development for NASA's 2020 Mars rover mission. In addition to the investigations that the Mars 2020 rover will conduct on Mars, the rover will collect carefully selected samples of Mars rock and soil and cache them to be available for possible return to Earth if a Mars sample-return mission is scheduled and flown. Each sample will be stored in a sealed tube. Adaptive caching would result in a set of samples, up to the maximum number of tubes carried on the rover, being placed on the surface at the discretion of the mission operators. The tubes holding the collected samples would not go into a surrounding container. In this illustration, green dots indicate "regions of interest," where samples might be collected. The green diamond indicates one region of interest serving as the depot for the cache. The green X at upper right represents the landing site. The solid black line indicates the rover's route during its prime mission, and the dashed black line indicates its route during an extension of the mission. The base image is a portion of the "Everest Panorama" taken by the panoramic camera on NASA's Mars Exploration Rover Spirit at the top of Husband Hill in 2005. http://photojournal.jpl.nasa.gov/catalog/PIA19150

  4. Dementia Special Care Units in Residential Care Communities: United States, 2010

    MedlinePlus

    ... of selection) of 81%. More details about sampling design and data collection are available elsewhere ( 4 ). Differences between communities with ... AJ, Harris-Kojetin LD, Sengupta M, et al. Design and operation of the 2010 National Survey of Residential Care Facilities. National Center for Health ...

  5. NATIONAL SCREENING SURVEY OF EDCS IN MUNICIPAL WASTEWATER TREATMENT FACILITIES

    EPA Science Inventory

    In 2002 and 2003 the USEPA's Office of Research and Development asked Regional EPA inspectors, state EPA inspectors and municipal plant operators to collect four gallons effluent, either as a grab or composite sample, from up to 50 wastewater treatment plants (WWTP), and ship the...

  6. Water Quality & Pollutant Source Monitoring: Field and Laboratory Procedures. Training Manual.

    ERIC Educational Resources Information Center

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This training manual presents material on techniques and instrumentation used to develop data in field monitoring programs and related laboratory operations concerned with water quality and pollution monitoring. Topics include: collection and handling of samples; bacteriological, biological, and chemical field and laboratory methods; field…

  7. Atmospheric Sampling on Ascension Island Using Multirotor UAVs.

    PubMed

    Greatwood, Colin; Richardson, Thomas S; Freer, Jim; Thomas, Rick M; MacKenzie, A Rob; Brownlow, Rebecca; Lowry, David; Fisher, Rebecca E; Nisbet, Euan G

    2017-05-23

    As part of an NERC-funded project investigating the southern methane anomaly, a team drawn from the Universities of Bristol, Birmingham and Royal Holloway flew small unmanned multirotors from Ascension Island for the purposes of atmospheric sampling. The objective of these flights was to collect air samples from below, within and above a persistent atmospheric feature, the Trade Wind Inversion, in order to characterise methane concentrations and their isotopic composition. These parameters allow the methane in the different air masses to be tied to different source locations, which can be further analysed using back trajectory atmospheric computer modelling. This paper describes the campaigns as a whole including the design of the bespoke eight rotor aircraft and the operational requirements that were needed in order to collect targeted multiple air samples up to 2.5 km above the ground level in under 20 min of flight time. Key features of the system described include real-time feedback of temperature and humidity, as well as system health data. This enabled detailed targeting of the air sampling design to be realised and planned during the flight mission on the downward leg, a capability that is invaluable in the presence of uncertainty in the pre-flight meteorological data. Environmental considerations are also outlined together with the flight plans that were created in order to rapidly fly vertical transects of the atmosphere whilst encountering changing wind conditions. Two sampling campaigns were carried out in September 2014 and July 2015 with over one hundred high altitude sampling missions. Lessons learned are given throughout, including those associated with operating in the testing environment encountered on Ascension Island.

  8. Water flow in high-speed handpieces.

    PubMed

    Cavalcanti, Bruno Neves; Serairdarian, Paulo Isaías; Rode, Sigmar Mello

    2005-05-01

    This study measured the water flow commonly used in high-speed handpieces to evaluate the water flow's influence on temperature generation. Different flow speeds were evaluated between turbines that had different numbers of cooling apertures. Two water samples were collected from each high-speed handpiece at private practices and at the School of Dentistry at São José dos Campos. The first sample was collected at the customary flow and the second was collected with the terminal opened for maximum flow. The two samples were collected into weighed glass receptacles after 15 seconds of turbine operation. The glass receptacles were reweighed and the difference between weights was recorded to calculate the water flow in mL/min and for further statistical analysis. The average water flow for 137 samples was 29.48 mL/min. The flow speeds obtained were 42.38 mL/min for turbines with one coolant aperture; 34.31 mL/min for turbines with two coolant apertures; and 30.44 mL/min for turbines with three coolant apertures. There were statistical differences between turbines with one and three coolant apertures (Tukey-Kramer multiple comparisons test with P < .05). Turbine handpieces with one cooling aperture distributed more water for the burs than high-speed handpieces with more than one aperture.

  9. Current collection from the space plasma through defects in high voltage solar array insulation. Ph.D. Thesis. Final Report

    NASA Technical Reports Server (NTRS)

    Stillwell, R. P.

    1983-01-01

    For spacecraft operation in the near Earth environment, solar cell arrays constitute the major source of reliable long term power. Optimization of mass and power efficiency results in a general requirement for high voltage solar arrays. The space plasma environment, though, can result in large currents being collected by exposed solar cells. The solution of a protective covering of transparent insulation is not a complete solution, inasmuch as defects in the insulation result in anomalously large currents being collected through the defects. Tests simulating the electron collection from small defects in an insulation have shown that there are two major collection modes. The first mode involves current enhancement by means of a surface phenomenon involving the surrounding insulator. In the second mode the current collection is enhanced by vaporization and ionization of the insulators materials, in addition to the surface enhancement of the first mode. A model for the electron collection is the surface enhanced collection mode was developed. The model relates the secondary electron emission yield to the electron collection. It correctly predicts the qualitative effects of hole size, sample temperature and roughening of sample surface. The theory was also shown to predict electron collection within a factor of two for the polymers teflon and polyimide.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fong, Erika J.; Huang, Chao; Hamilton, Julie

    Here, a major advantage of microfluidic devices is the ability to manipulate small sample volumes, thus reducing reagent waste and preserving precious sample. However, to achieve robust sample manipulation it is necessary to address device integration with the macroscale environment. To realize repeatable, sensitive particle separation with microfluidic devices, this protocol presents a complete automated and integrated microfluidic platform that enables precise processing of 0.15–1.5 ml samples using microfluidic devices. Important aspects of this system include modular device layout and robust fixtures resulting in reliable and flexible world to chip connections, and fully-automated fluid handling which accomplishes closed-loop sample collection,more » system cleaning and priming steps to ensure repeatable operation. Different microfluidic devices can be used interchangeably with this architecture. Here we incorporate an acoustofluidic device, detail its characterization, performance optimization, and demonstrate its use for size-separation of biological samples. By using real-time feedback during separation experiments, sample collection is optimized to conserve and concentrate sample. Although requiring the integration of multiple pieces of equipment, advantages of this architecture include the ability to process unknown samples with no additional system optimization, ease of device replacement, and precise, robust sample processing.« less

  11. Toward Lower Organic Environments in Astromaterial Sample Curation for Diverse Collections

    NASA Technical Reports Server (NTRS)

    Allton, J. H.; Allen, C. C.; Burkett, P. J.; Calaway, M. J.; Oehler, D. Z.

    2012-01-01

    Great interest was taken during the frenzied pace of the Apollo lunar sample return to achieve and monitor organic cleanliness. Yet, the first mission resulted in higher organic contamination to samples than desired. But improvements were accomplished by Apollo 12 [1]. Quarantine complicated the goal of achieving organic cleanliness by requiring negative pressure glovebox containment environments, proximity of animal, plant and microbial organic sources, and use of organic sterilants in protocols. A special low organic laboratory was set up at University of California Berkeley (UCB) to cleanly subdivide a subset of samples [2, 3, 4]. Nevertheless, the basic approach of handling rocks and regolith inside of a positive pressure stainless steel glovebox and restrict-ing the tool and container materials allowed in the gloveboxes was established by the last Apollo sample re-turn. In the last 40 years, the collections have grown to encompass Antarctic meteorites, Cosmic Dust, Genesis solar wind, Stardust comet grains and Hayabusa asteroid grains. Each of these collections have unique curation requirements for organic contamination monitor-ing and control. Here is described some changes allowed by improved technology or driven by changes in environmental regulations and economy, concluding with comments on organic witness wafers. Future sample return missions (OSIRIS-Rex; Mars; comets) will require extremely low levels of organic contamination in spacecraft collection and thus similarly low levels in curation. JSC Curation is undertaking a program to document organic baseline levels in current operations and devise ways to reduce those levels.

  12. Guide for SDEC Set up

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bibby, R; Guthrie, E

    2009-01-30

    The instrument has four collection vials that must be filled with ethylene glycol before operation. Each of the four vials should be labeled 1 through 4 and the empty weights recorded. Fill each vial with 80 mL of ethylene glycol and record the weight again. In order for the instrument to operate properly, the collection vials should always have less than 160 mL of total liquid in them. After completing a sample run, remove the collection vials, use a transfer pipette to remove any liquid that might still be on the air paddler, wipe off any condensation from the exteriormore » of the collection vial and record weight. From the instrument, record the ending volume and the time of operation. The solution mixed in the scintillation vial will be 2 ml of a 95% to 50% ethylene glycol to water mixture. To determine the efficiency of counting at all of these concentrations, a series of vials should be set up that consist of 18 ml of Ultima Gold LLT cocktail mixed with standard, regular deionized water and ethylene glycol. The efficiency curve should be counted in the 'Low Level' count mode with the Luminescence Correction ON and the Color Quench Correction ON. Once the tSIE values are determined, chart the cpm against the tSIE numbers and find the best fit for the data. The resulting equation is to be used to converting tSIE values from the collection vials to efficiency. To determine the background cpm value of the ethylene glycol, count a 2 ml sample of ethylene glycol with 18 ml of Ultima Gold for 100 minutes. To determine the total activity of the sample, take two 2 ml aliquots of sample from the first vial and place in separate scintillation vials. Record the weight of each aliquot. Determine the percentage of total sample each aliquot represents by dividing the aliquot weight by the total solution weight from the vial. Also, determine the percentage of ethylene glycol in the sample by dividing the initial solution weight by the final solution weight and multiplying by 100. Add 18 ml of Ultima Gold to each vial and proceed to count for 100 minutes in a 'Low Level' count mode. Before performing a calculation on the dpm value of each aliquot, a subtraction should be made for the background count rate of the ethylene glycol. Based on the background cpm, multiply the background cpm value by the percentage of ethylene glycol in the collection vial. Once the background value is subtracted, calculate the dpm value of the sample based on the tSIE conversion to efficiency. This will produce a dpm value. To convert this to a total activity of the sample, divide the aliquot dpm value by the decimal percentage of total sample the aliquot represents. This gives the total activity of the sample solution. Take the average of both aliquots as a final result. To convert the total activity from the solution in vial one to activity in air, an empirical formula is used to convert activity/gram from vial one to total activity introduced into the system. After calculation the final result for the vial, divide the total by the mass of the sample in vial one. This gives dpm/g (labeled C{sub m}). To convert this to total dpm measured, C = (128.59 * Cm + 10.837)/V Where: C = Tritium concentration in air (dpm/m{sup 3}) C{sub m} = measured tritium concentration from vial 1 (dpm/g) V = Volume of air sampled through instrument (m{sup 3}). C is the final value of tritium concentration in air.« less

  13. Horizons, Helping Shape the Future of SOF. Issue 3, Fall 2009

    DTIC Science & Technology

    2009-01-01

    OIL quickly through the SOF, conventional, and inter-agency communities . Samples of Success LLATs have collected on a variety of topics. This...with the broader SE community so they did not reside solely at one operating site. Mr. David Hilliard, a Boeing mechanic operator, retrieves a...said a 1SFG soldier. It was critical that every aspect of the story incorporated an Iraqi face, such as Tiba’s, to communicate and emphasize Tiba’s

  14. Antarctica EVA

    NASA Technical Reports Server (NTRS)

    Love, Stan

    2013-01-01

    NASA astronaut Stan Love shared his experiences with the Antarctic Search for Meteorites (ANSMET), an annual expedition to the southern continent to collect valuable samples for research in planetary science. ANSMET teams operate from isolated, remote field camps on the polar plateau, where windchill factors often reach -40? F. Several astronaut participants have noted ANSMET's similarity to a space mission. Some of the operational concepts, tools, and equipment employed by ANSMET teams may offer valuable insights to designers of future planetary surface exploration hardware.

  15. Hydrologic Monitoring in the Deep Subsurface to Support Repository Performance

    NASA Astrophysics Data System (ADS)

    Hubbell, J. M.; Heath, G. L.; Scott, C. L.

    2007-12-01

    The INL has installed and operated several vadose and ground water monitoring systems in arid and humid sites to depths of about 200m. Some of these systems have been in continuous operation for over 12 years. It is important that the systems be physically robust, simple, yet versatile enough that it can operate for extended time periods with little or no maintenance. Monitoring instruments are frequently installed and run to characterize the site, collect data during site operation, and continue to run for long-term stewardship, necessitating sensors that can be maintained or serviced. Sensors are carefully chosen based on the perceived data requirements over the life of the site. An emphasis is given on direct measurements such as tensiometers (portable and advanced), neutron probe, drain gauge, temperature, wells or sampling for fluids and gases. Other complementary data can include using TDR/capacitance, radiation detectors, and larger scale geophysical techniques (3-d resistivity and EM) for volumetric measurements. Commercially available instruments may have to be modified for their use at greater depths, to allow multiple instruments in a single borehole or to perform the intended monitoring function. Access tubes (some open at the bottom) can be placed to allow insertion of multiple sensors (radiation, neutron and portable sensors/samplers), future drilling/sampling and to install new instruments at a later time. The installation techniques and backfill materials must be chosen and the measurement technique tested to ensure representative data collection for the parameters of interest. The data collection system can be linked to climatic data (precipitation, barometric pressure, snow depth, runoff, surface water sources) that may influence the site's subsurface hydrology. The instruments are then connected to a real-time automated data collection system that collect, stores, and provides access to the data. These systems have been developed that allow easy access, automatic data quality checks with notification, processing, and presentation of the data in real time through the web. The systems can be designed to manipulate/test the system remotely. Data from several sites will be presented showing that continuous monitoring is necessary to detect rapid changes in the deep vadose zone and ground water at fractured rock sites.

  16. Portable Automation of Static Chamber Sample Collection for Quantifying Soil Gas Flux

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Morgan P.; Groh, Tyler A.; Parkin, Timothy B.

    Quantification of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled is limited by the spacing between chambers and the availability of trained research technicians. An automated system for collecting gas samples from chambers in the field would eliminate the need for personnel to return to the chamber during a flux measurement period and would allow a single technician to sample multiple chambers simultaneously. This study describes Chamber Automated Sampling Equipment (FluxCASE) to collect and store chamber headspace gas samples at assigned time points for the measurement of soil gasmore » flux. The FluxCASE design and operation is described, and the accuracy and precision of the FluxCASE system is evaluated. In laboratory measurements of nitrous oxide (N2O), carbon dioxide (CO2), and methane (CH4) concentrations of a standardized gas mixture, coefficients of variation associated with automated and manual sample collection were comparable, indicating no loss of precision. In the field, soil gas fluxes measured from FluxCASEs were in agreement with manual sampling for both N2O and CO2. Slopes of regression equations were 1.01 for CO2 and 0.97 for N2O. The 95% confidence limits of the slopes of the regression lines included the value of one, indicating no bias. Additionally, an expense analysis found a cost recovery ranging from 0.6 to 2.2 yr. Implementing the FluxCASE system is an alternative to improve the efficiency of the static chamber method for measuring soil gas flux while maintaining the accuracy and precision of manual sampling.« less

  17. Development and Flight Testing of an Adaptive Vehicle Health-Monitoring Architecture

    NASA Technical Reports Server (NTRS)

    Woodard, Stanley E.; Coffey, Neil C.; Gonzalez, Guillermo A.; Taylor, B. Douglas; Brett, Rube R.; Woodman, Keith L.; Weathered, Brenton W.; Rollins, Courtney H.

    2002-01-01

    On going development and testing of an adaptable vehicle health-monitoring architecture is presented. The architecture is being developed for a fleet of vehicles. It has three operational levels: one or more remote data acquisition units located throughout the vehicle; a command and control unit located within the vehicle, and, a terminal collection unit to collect analysis results from all vehicles. Each level is capable of performing autonomous analysis with a trained expert system. The expert system is parameterized, which makes it adaptable to be trained to both a user's subject reasoning and existing quantitative analytic tools. Communication between all levels is done with wireless radio frequency interfaces. The remote data acquisition unit has an eight channel programmable digital interface that allows the user discretion for choosing type of sensors; number of sensors, sensor sampling rate and sampling duration for each sensor. The architecture provides framework for a tributary analysis. All measurements at the lowest operational level are reduced to provide analysis results necessary to gauge changes from established baselines. These are then collected at the next level to identify any global trends or common features from the prior level. This process is repeated until the results are reduced at the highest operational level. In the framework, only analysis results are forwarded to the next level to reduce telemetry congestion. The system's remote data acquisition hardware and non-analysis software have been flight tested on the NASA Langley B757's main landing gear. The flight tests were performed to validate the following: the wireless radio frequency communication capabilities of the system, the hardware design, command and control; software operation and, data acquisition, storage and retrieval.

  18. Deep-Sea decapod crustaceans (Caridea, Polychelida, Anomura and Brachyura) collected from the Nikko Seamounts, Mariana Arc, using a remotely operated vehicle "Hyper-Dolphin".

    PubMed

    Komai, Tomoyuki; Tsuchida, Shinji

    2014-02-11

    Samples and images of deep-water benthic decapod crustaceans were collected from the Nikko Seamounts, Mariana Arc, at depths of 520-680 m, by using the remotely operate vehicle "Hyper-Dolphin", equipped with a high definition camera, digital camera, manipulators and slurp gun (suction sampler). The following seven species were collected, of which three are new to science: Plesionika unicolor n. sp. (Caridea: Pandalidae), Homeryon armarium Galil, 2000 (Polychelida: Polychelidae), Eumunida nikko n. sp. (Anomura: Eumunididae), Michelopagurus limatulus (Henderson, 1888) (Anomura: Paguridae), Galilia petricola n. sp. (Brachyura: Leucosiidae), Cyrtomaia micronesica Richer de Forges & Ng, 2007 (Brachyura: Inachidae), and Progeryon mus Ng & Guinot, 1999 (Brachyura: Progeryonidae). Affinities of these three new species are discussed. All but H. armarium are recorded from the Japanese Exclusive Economic Zone for the first time. Brief notes on ecology and/or behavior are given for each species.

  19. Snow and Ice Mask for the MODIS Aerosol Products

    NASA Technical Reports Server (NTRS)

    Li, Rong-Rong; Remer, Lorraine; Kaufman, Yoram J.; Mattoo, Shana; Gao, Bo-Cai; Vermote, Eric

    2005-01-01

    The atmospheric products have been derived operationally from multichannel imaging data collected with the Moderate Resolution Imaging SpectroRadiometers (MODIS) on board the NASA Terra and Aqua spacecrafts. Preliminary validations of the products were previously reported. Through analysis of more extensive time-series of MODIS aerosol products (Collection 4), we have found that the aerosol products over land areas are slightly contaminated by snow and ice during the springtime snow-melting season. We have developed an empirical technique using MODIS near-IR channels centered near 0.86 and 1.24 pm and a thermal emission channel near 11 pm to mask out these snow-contaminated pixels over land. Improved aerosol retrievals over land have been obtained. Sample results from application of the technique to MODIS data acquired over North America, northern Europe, and northeastern Asia are presented. The technique has been implemented into the MODIS Collection 5 operational algorithm for retrieving aerosols over land from MODIS data.

  20. Induced Environment Contamination Monitor (IECM), air sampler - Results from the Space Transport System (STS-2) flight

    NASA Technical Reports Server (NTRS)

    Peters, P. N.; Hester, H. B.; Bertsch, W.; Mayfield, H.; Zatko, D.

    1983-01-01

    An investigation involving sampling the rapidly changing environment of the Shuttle cargo bay is considered. Four time-integrated samples and one rapid acquisition sample were collected to determine the types and quantities of contaminants present during ascent and descent of the Shuttle. The sampling times for the various bottles were controlled by valves operated by the Data Acquisition and Control System (DACS) of the IECM. Many of the observed species were found to be common solvents used in cleaning surfaces. When the actual volume sampled is taken into account, the relative mass of organics sampled during descent is about 20 percent less than during ascent.

  1. Elemental composition of airborne dust in the Shale Shaker House during an offshore drilling operation.

    PubMed

    Hansen, A B; Larsen, E; Hansen, L V; Lyngsaae, M; Kunze, H

    1991-12-01

    During 2 days of an offshore drilling operation in the North Sea, 16 airborne dust samples from the atmosphere of the Shale Shaker House were collected onto filters. During this operation, drilling mud composed of a water slurry of barite (BaSO4) together with minor amounts of additives, among them chrome lignosulphonate and chrome lignite, was circulated between the borehole and the Shale Shaker House. The concentration of airborne dust in the atmosphere was determined and the elemental composition of the particles analysed by both PIXE (proton-induced X-ray emission) and ICP-MS (inductively coupled plasma-mass spectrometry). The total amount of dust collected varied from 0.04 to 1.41 mg m-3 with barium (Ba) as the single most abundant element. The open shale shakers turned out to be the major cause of generation of dust from the solid components of the drilling mud.

  2. Evaluation of the US Army Institute of Public Health Destination Monitoring Program, a food safety surveillance program.

    PubMed

    Rapp-Santos, Kamala; Havas, Karyn; Vest, Kelly

    2015-01-01

    The Destination Monitoring Program, operated by the US Army Public Health Command (APHC), is one component that supports the APHC Veterinary Service's mission to ensure safety and quality of food procured for the Department of Defense (DoD). This program relies on retail product testing to ensure compliance of production facilities and distributors that supply food to the DoD. This program was assessed to determine the validity and timeliness by specifically evaluating whether sample size of items collected was adequate, if food samples collected were representative of risk, and whether the program returns results in a timely manner. Data was collected from the US Army Veterinary Services Lotus Notes database, including all food samples collected and submitted from APHC Region-North for the purposes of destination monitoring from January 1, 2013 to December 31, 2013. For most food items, only one sample was submitted for testing. The ability to correctly identify a contaminated food lot may be limited by reliance on test results from only one sample, as the level of confidence in a negative test result is low. The food groups most frequently sampled by APHC correlated with the commodities that were implicated in foodborne illness in the United States. Food items to be submitted were equally distributed among districts and branches, but sections within large branches submitted relatively few food samples compared to sections within smaller branches and districts. Finally, laboratory results were not available for about half the food items prior to their respective expiration dates.

  3. A Modified Content Analysis of Existing School Psychology Reports

    ERIC Educational Resources Information Center

    Mallin, Barry; Schellenberg, Miriam E.; Smith, Christiane

    2012-01-01

    Discrepancies between our university's training program's report-writing guidelines and common practice in Manitoba could not be resolved by reference to the literature. To inform the discussion, we collected a sample of local real world school psychology reports and undertook a modified content analysis to operationally define and measure…

  4. Prevalence of Campylobacter spp. in bulk tank milk and filters from US dairies

    USDA-ARS?s Scientific Manuscript database

    Campylobacter spp. is an important zoonotic microaerophilic bacterial pathogen that caused the majority of US outbreaks associated with nonpasteurized milk from 2007 to 2012. Bulk tank milk and milk filter samples were collected from 236 dairy operations in 17 top dairy states from March through Jul...

  5. Journal: Efficient Hydrologic Tracer-Test Design for Tracer-Mass Estimation and Sample Collection Frequency, 1 Method Development

    EPA Science Inventory

    Hydrological tracer testing is the most reliable diagnostic technique available for the determination of basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowl...

  6. ENVIRONMENTAL MONITORING AND ASSESSMENT - GREAT RIVER ECOSYSTEMS PROGRAM (EMAP-GRE) GREAT RIVER ECOSYSTEMS FIELD OPERATIONS MANUAL

    EPA Science Inventory

    This manual describes procedures for collecting samples and field measurements for biotic assemblages and abiotic characteristics of the Great Rivers of the Central Basin of the United States: the Missouri, Upper Mississippi, and Ohio Rivers. In addition to the technical and logi...

  7. An Accounting System for Solid Waste Management in Small Communities.

    ERIC Educational Resources Information Center

    Zausner, Eric R.

    This pamphlet provides a guide to the type and quantity of information to be collected for effective solid waste management in small communities. It is directed at municipal or private personnel involved in the operation and ownership of management facilities. Sample activity reports are included for reference. (CS)

  8. CERC Field Research Facility Environmental Data Summary, 1977-79.

    DTIC Science & Technology

    1982-12-01

    Motorola "Mini-Ranger," coupled to a Hewlett-Packard Mini-Computer and flatbed plotter. This positioning system was put together and operated by Prank... laminations within the core. While one diver collected the sample, the second diver recorded conditions on the bottom. This description included sediment

  9. 40 CFR 58.12 - Operating schedules.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... seasons exempted by the Regional Administrator. (b) For Pb manual methods, at least one 24-hour sample must be collected every 6 days except during periods or seasons exempted by the Regional Administrator... and must be approved by the Regional Administrator. (d) For manual PM 2.5 samplers: (1)(i) Manual PM 2...

  10. 40 CFR 58.12 - Operating schedules.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... seasons exempted by the Regional Administrator. (b) For Pb manual methods, at least one 24-hour sample must be collected every 6 days except during periods or seasons exempted by the Regional Administrator... and must be approved by the Regional Administrator. (d) For manual PM 2.5 samplers: (1)(i) Manual PM 2...

  11. Prevalence of internal parasites in beef cows in the United States: Results of the National Animal Health Monitoring System's (NAHMS) beef study, 2007-2008.

    PubMed

    Stromberg, Bert E; Gasbarre, Louis C; Ballweber, Lora R; Dargatz, David A; Rodriguez, Judith M; Kopral, Christine A; Zarlenga, Dante S

    2015-10-01

    During the United States Department of Agriculture (USDA) National Animal Health Monitoring System's (NAHMS) 2007-2008 beef study, 567 producers from 24 US States were offered the opportunity to collect fecal samples from weaned beef calves and have them evaluated for the presence of parasite eggs (Phase 1). Participating producers were provided with instructions and materials for sample collection. Up to 20 fresh fecal samples were collected from each of the 99 participating operations. Fresh fecal samples were submitted to one of 3 randomly assigned laboratories for evaluation. Upon arrival at the laboratories, all samples were processed for the enumeration of strongyle, Nematodirus, and Trichuris eggs using the modified Wisconsin technique. The presence or absence of coccidian oocysts and tapeworm eggs was also noted. In submissions where the strongyle eggs per gram exceeded 30, aliquots from 2 to 6 animals were pooled for DNA extraction. Extracted DNA was subjected to genus level polymerase chain reaction (PCR) identification for the presence of Ostertagia, Cooperia, Haemonchus, Oesophagostomum, and Trichostrongylus. In this study, 85.6% of the samples had strongyle type, Nematodirus, and Trichuris eggs. Among the samples evaluated, 91% had Cooperia, 79% Ostertagia, 53% Haemonchus, 38% Oesophagostomum, 18% Nematodirus, 7% Trichuris, and 3% Trichostrongylus. The prevalence of coccidia and tapeworm eggs was 59.9% and 13.7%, respectively.

  12. Prevalence of internal parasites in beef cows in the United States: Results of the National Animal Health Monitoring System’s (NAHMS) beef study, 2007–2008

    PubMed Central

    Stromberg, Bert E.; Gasbarre, Louis C.; Ballweber, Lora R.; Dargatz, David A.; Rodriguez, Judith M.; Kopral, Christine A.; Zarlenga, Dante S.

    2015-01-01

    During the United States Department of Agriculture (USDA) National Animal Health Monitoring System’s (NAHMS) 2007–2008 beef study, 567 producers from 24 US States were offered the opportunity to collect fecal samples from weaned beef calves and have them evaluated for the presence of parasite eggs (Phase 1). Participating producers were provided with instructions and materials for sample collection. Up to 20 fresh fecal samples were collected from each of the 99 participating operations. Fresh fecal samples were submitted to one of 3 randomly assigned laboratories for evaluation. Upon arrival at the laboratories, all samples were processed for the enumeration of strongyle, Nematodirus, and Trichuris eggs using the modified Wisconsin technique. The presence or absence of coccidian oocysts and tapeworm eggs was also noted. In submissions where the strongyle eggs per gram exceeded 30, aliquots from 2 to 6 animals were pooled for DNA extraction. Extracted DNA was subjected to genus level polymerase chain reaction (PCR) identification for the presence of Ostertagia, Cooperia, Haemonchus, Oesophagostomum, and Trichostrongylus. In this study, 85.6% of the samples had strongyle type, Nematodirus, and Trichuris eggs. Among the samples evaluated, 91% had Cooperia, 79% Ostertagia, 53% Haemonchus, 38% Oesophagostomum, 18% Nematodirus, 7% Trichuris, and 3% Trichostrongylus. The prevalence of coccidia and tapeworm eggs was 59.9% and 13.7%, respectively. PMID:26424909

  13. Method of multivariate spectral analysis

    DOEpatents

    Keenan, Michael R.; Kotula, Paul G.

    2004-01-06

    A method of determining the properties of a sample from measured spectral data collected from the sample by performing a multivariate spectral analysis. The method can include: generating a two-dimensional matrix A containing measured spectral data; providing a weighted spectral data matrix D by performing a weighting operation on matrix A; factoring D into the product of two matrices, C and S.sup.T, by performing a constrained alternating least-squares analysis of D=CS.sup.T, where C is a concentration intensity matrix and S is a spectral shapes matrix; unweighting C and S by applying the inverse of the weighting used previously; and determining the properties of the sample by inspecting C and S. This method can be used to analyze X-ray spectral data generated by operating a Scanning Electron Microscope (SEM) with an attached Energy Dispersive Spectrometer (EDS).

  14. Baseline tests for arc melter vitrification of INEL buried wastes. Volume II: Baseline test data appendices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oden, L.L.; O`Conner, W.K.; Turner, P.C.

    1993-11-19

    This report presents field results and raw data from the Buried Waste Integrated Demonstration (BWID) Arc Melter Vitrification Project Phase 1 baseline test series conducted by the Idaho National Engineering Laboratory (INEL) in cooperation with the U.S. Bureau of Mines (USBM). The baseline test series was conducted using the electric arc melter facility at the USBM Albany Research Center in Albany, Oregon. Five different surrogate waste feed mixtures were tested that simulated thermally-oxidized, buried, TRU-contaminated, mixed wastes and soils present at the INEL. The USBM Arc Furnace Integrated Waste Processing Test Facility includes a continuous feed system, the arc meltingmore » furnace, an offgas control system, and utilities. The melter is a sealed, 3-phase alternating current (ac) furnace approximately 2 m high and 1.3 m wide. The furnace has a capacity of 1 metric ton of steel and can process as much as 1,500 lb/h of soil-type waste materials. The surrogate feed materials included five mixtures designed to simulate incinerated TRU-contaminated buried waste materials mixed with INEL soil. Process samples, melter system operations data and offgas composition data were obtained during the baseline tests to evaluate the melter performance and meet test objectives. Samples and data gathered during this program included (a) automatically and manually logged melter systems operations data, (b) process samples of slag, metal and fume solids, and (c) offgas composition, temperature, velocity, flowrate, moisture content, particulate loading and metals content. This report consists of 2 volumes: Volume I summarizes the baseline test operations. It includes an executive summary, system and facility description, review of the surrogate waste mixtures, and a description of the baseline test activities, measurements, and sample collection. Volume II contains the raw test data and sample analyses from samples collected during the baseline tests.« less

  15. Baseline tests for arc melter vitrification of INEL buried wastes. Volume 1: Facility description and summary data report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oden, L.L.; O`Connor, W.K.; Turner, P.C.

    1993-11-19

    This report presents field results and raw data from the Buried Waste Integrated Demonstration (BWID) Arc Melter Vitrification Project Phase 1 baseline test series conducted by the Idaho National Engineering Laboratory (INEL) in cooperation with the U.S. Bureau of Mines (USBM). The baseline test series was conducted using the electric arc melter facility at the USBM Albany Research Center in Albany, Oregon. Five different surrogate waste feed mixtures were tested that simulated thermally-oxidized, buried, TRU-contaminated, mixed wastes and soils present at the INEL. The USBM Arc Furnace Integrated Waste Processing Test Facility includes a continuous feed system, the arc meltingmore » furnace, an offgas control system, and utilities. The melter is a sealed, 3-phase alternating current (ac) furnace approximately 2 m high and 1.3 m wide. The furnace has a capacity of 1 metric ton of steel and can process as much as 1,500 lb/h of soil-type waste materials. The surrogate feed materials included five mixtures designed to simulate incinerated TRU-contaminated buried waste materials mixed with INEL soil. Process samples, melter system operations data and offgas composition data were obtained during the baseline tests to evaluate the melter performance and meet test objectives. Samples and data gathered during this program included (a) automatically and manually logged melter systems operations data, (b) process samples of slag, metal and fume solids, and (c) offgas composition, temperature, velocity, flowrate, moisture content, particulate loading and metals content. This report consists of 2 volumes: Volume I summarizes the baseline test operations. It includes an executive summary, system and facility description, review of the surrogate waste mixtures, and a description of the baseline test activities, measurements, and sample collection. Volume II contains the raw test data and sample analyses from samples collected during the baseline tests.« less

  16. Site characterization summary report for dry weather surface water sampling upper East Fork Poplar Creek characterization area Oak Ridge Y-12 Plant, Oak Ridge, Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This report describes activities associated with conducting dry weather surface water sampling of Upper East Fork Poplar Creek (UEFPC) at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee. This activity is a portion of the work to be performed at UEFPC Operable Unit (OU) 1 [now known as the UEFPC Characterization Area (CA)], as described in the RCRA Facility Investigation Plan for Group 4 at the Oak- Ridge Y-12 Plant, Oak Ridge, Tennessee and in the Response to Comments and Recommendations on RCRA Facility Investigation Plan for Group 4 at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee, Volume 1,more » Operable Unit 1. Because these documents contained sensitive information, they were labeled as unclassified controlled nuclear information and as such are not readily available for public review. To address this issue the U.S. Department of Energy (DOE) published an unclassified, nonsensitive version of the initial plan, text and appendixes, of this Resource Conservation and Recovery Act (RCRA) Facility Investigation (RFI) Plan in early 1994. These documents describe a program for collecting four rounds of wet weather and dry weather surface water samples and one round of sediment samples from UEFPC. They provide the strategy for the overall sample collection program including dry weather sampling, wet weather sampling, and sediment sampling. Figure 1.1 is a schematic flowchart of the overall sampling strategy and other associated activities. A Quality Assurance Project Plan (QAPJP) was prepared to specifically address four rounds of dry weather surface water sampling and one round of sediment sampling. For a variety of reasons, sediment sampling has not been conducted and has been deferred to the UEFPC CA Remedial Investigation (RI), as has wet weather sampling.« less

  17. Longitudinal prevalence and molecular typing of Escherichia coli O157:H7 by use of multiple-locus variable-number tandem-repeat analysis and pulsed-field gel electrophoresis in fecal samples collected from a range-based herd of beef cattle in California.

    PubMed

    Kondo, Sonoko; Hoar, Bruce R; Villanueva, Veronica; Mandrell, Robert E; Atwill, Edward R

    2010-11-01

    To evaluate seasonal patterns and risk factors for Escherichia coli O157:H7 in feces in a beef cattle herd and determine strain diversity and transition in E coli over time by use of multiple-locus variable-number tandem-repeat analysis (MLVA) and pulsed-field gel electrophoresis (PFGE). 456 samples of freshly passed feces collected over a 1-year period from cattle in a range-based cow-calf operation located in the foothills of the Sierra Nevada Mountains in California. E coli O157:H7 was recovered from feces by use of immunomagnetic separation and 2 selective media. Virulence factors were detected via reverse transcriptase-PCR assay. Escherichia coli O157:H7 isolates were subtyped with MLVA and PFGE. Prevalence estimates were calculated and significant risk factors determined. A dendrogram was constructed on the basis of results of MLVA typing. Overall prevalence estimate for E coli O157:H7 was 10.5%, with the prevalence lowest during the winter. Mean temperature during the 30 days before collection of samples was significantly associated with prevalence of E coli O157:H7 in feces. Nineteen MLVA and 12 PFGE types were identified. A seasonal pattern was detected for prevalence of E coli O157:H7 in feces collected from beef cattle in California. Subtyping via MLVA and PFGE revealed a diversity of E coli O157:H7 strains in a cow-calf operation and noteworthy turnover of predominant types. Given the importance of accurately determining sources of contamination in investigations of disease outbreaks in humans, MLVA combined with PFGE should be powerful tools for epidemiologists.

  18. Optimizing Anesthesia-Related Waste Disposal in the Operating Room: A Brief Report.

    PubMed

    Hubbard, Richard M; Hayanga, Jeremiah A; Quinlan, Joseph J; Soltez, Anita K; Hayanga, Heather K

    2017-10-01

    Misappropriation of noncontaminated waste into regulated medical waste (RMW) containers is a source of added expense to health care facilities. The operating room is a significant contributor to RMW waste production. This study sought to determine whether disposing of anesthesia-related waste in standard waste receptacles before patient entry into the operating room would produce a reduction in RMW. A median of 0.35 kg of waste was collected from 51 cases sampled, with a potential annual reduction of 13,800 kg of RMW to the host institution, and a cost savings of $2200.

  19. Systems and methods for analyzing building operations sensor data

    DOEpatents

    Mezic, Igor; Eisenhower, Bryan A.

    2015-05-26

    Systems and methods are disclosed for analyzing building sensor information and decomposing the information therein to a more manageable and more useful form. Certain embodiments integrate energy-based and spectral-based analysis methods with parameter sampling and uncertainty/sensitivity analysis to achieve a more comprehensive perspective of building behavior. The results of this analysis may be presented to a user via a plurality of visualizations and/or used to automatically adjust certain building operations. In certain embodiments, advanced spectral techniques, including Koopman-based operations, are employed to discern features from the collected building sensor data.

  20. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    NASA Technical Reports Server (NTRS)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  1. Geochemistry and mercury contamination in receiving environments of artisanal mining wastes and identified concerns for food safety.

    PubMed

    Reichelt-Brushett, Amanda J; Stone, Jane; Howe, Pelli; Thomas, Bernard; Clark, Malcolm; Male, Yusthinus; Nanlohy, Albert; Butcher, Paul

    2017-01-01

    Artisanal small-scale gold mining (ASGM) using mercury (Hg) amalgamation has been occurring on Buru Island, Indonesia since early 2012, and has caused rapid accumulation of high Hg concentrations in river, estuary and marine sediments. In this study, sediment samples were collected from several sites downstream of the Mount Botak ASGM site, as well as in the vicinity of the more recently established site at Gogrea where no sampling had previously been completed. All sediment samples had total Hg (THg) concentrations exceeding Indonesian sediment quality guidelines and were up to 82 times this limit at one estuary site. The geochemistry of sediments in receiving environments indicates the potential for Hg-methylation to form highly bioavailable Hg species. To assess the current contamination threat from consumption of local seafood, samples of fish, molluscs and crustaceans were collected from the Namlea fish market and analysed for THg concentrations. The majority of edible tissue samples had elevated THg concentrations, which raises concerns for food safety. This study shows that river, estuary and marine ecosystems downstream of ASGM operations on Buru Island are exposed to dangerously high Hg concentrations, which are impacting aquatic food chains, and fisheries resources. Considering the high dietary dependence on marine protein in the associated community and across the Mollucas Province, and the short time period since ASGM operations commenced in this region, the results warrant urgent further investigation, risk mitigation, and community education. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Survey methods for assessing land cover map accuracy

    USGS Publications Warehouse

    Nusser, S.M.; Klaas, E.E.

    2003-01-01

    The increasing availability of digital photographic materials has fueled efforts by agencies and organizations to generate land cover maps for states, regions, and the United States as a whole. Regardless of the information sources and classification methods used, land cover maps are subject to numerous sources of error. In order to understand the quality of the information contained in these maps, it is desirable to generate statistically valid estimates of accuracy rates describing misclassification errors. We explored a full sample survey framework for creating accuracy assessment study designs that balance statistical and operational considerations in relation to study objectives for a regional assessment of GAP land cover maps. We focused not only on appropriate sample designs and estimation approaches, but on aspects of the data collection process, such as gaining cooperation of land owners and using pixel clusters as an observation unit. The approach was tested in a pilot study to assess the accuracy of Iowa GAP land cover maps. A stratified two-stage cluster sampling design addressed sample size requirements for land covers and the need for geographic spread while minimizing operational effort. Recruitment methods used for private land owners yielded high response rates, minimizing a source of nonresponse error. Collecting data for a 9-pixel cluster centered on the sampled pixel was simple to implement, and provided better information on rarer vegetation classes as well as substantial gains in precision relative to observing data at a single-pixel.

  3. Hepatitis E virus and coliphages in waters proximal to swine concentrated animal feeding operations.

    PubMed

    Gentry-Shields, Jennifer; Myers, Kevin; Pisanic, Nora; Heaney, Christopher; Stewart, Jill

    2015-02-01

    North Carolina is the second leading state in pork production in the United States, with over 10 million swine. Swine manure in NC is typically collected and stored in open-pit lagoons before the liquid waste is sprayed onto agricultural fields for disposal. Components of this waste may be able to impact surface water quality with the potential for human exposure. This study examined viruses of public health concern in creeks adjacent to swine concentrated animal feeding operation (CAFO) spray fields. Surface water samples (n=154) were collected from public access waters in proximity to swine CAFO spray fields for six months and were tested for hepatitis E virus (HEV) and coliphages. HEV was detected in one sample. Somatic coliphages were detected in 98% of samples (geometric mean 24 ± 4.1 PFU per 100 ml), and F+ coliphages were detected in 85% of samples (geometric mean 6.8 ± 5.0 PFU per 100 ml). Only 3% (21) of the F+ coliphage isolates were RNA phage, and all of the F+ RNA coliphages belonged to genogroup I. Although the pervasiveness of swine CAFOs in this area prevented a comparison with samples from un-impacted sites, the near ubiquity of coliphages, as well as the presence of HEV, suggests that current waste management practices may be associated with the dissemination of viruses of public health concern in waters proximal to CAFO spray fields. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. 2014 NASA Centennial Challenges Sample Return Robot Challenge

    NASA Image and Video Library

    2014-06-11

    Team KuuKulgur waits to begin the level one challenge during the 2014 NASA Centennial Challenges Sample Return Robot Challenge, Wednesday, June 11, 2014, at the Worcester Polytechnic Institute (WPI) in Worcester, Mass. Eighteen teams are competing for a $1.5 million NASA prize purse. Teams will be required to demonstrate autonomous robots that can locate and collect samples from a wide and varied terrain, operating without human control. The objective of this NASA-WPI Centennial Challenge is to encourage innovations in autonomous navigation and robotics technologies. Innovations stemming from the challenge may improve NASA's capability to explore a variety of destinations in space, as well as enhance the nation's robotic technology for use in industries and applications on Earth. Photo Credit: (NASA/Joel Kowsky)during the 2014 NASA Centennial Challenges Sample Return Robot Challenge, Wednesday, June 11, 2014, at the Worcester Polytechnic Institute (WPI) in Worcester, Mass. Eighteen teams are competing for a $1.5 million NASA prize purse. Teams will be required to demonstrate autonomous robots that can locate and collect samples from a wide and varied terrain, operating without human control. The objective of this NASA-WPI Centennial Challenge is to encourage innovations in autonomous navigation and robotics technologies. Innovations stemming from the challenge may improve NASA's capability to explore a variety of destinations in space, as well as enhance the nation's robotic technology for use in industries and applications on Earth. Photo Credit: (NASA/Joel Kowsky)

  5. The Navruz Project: Transboundary Monitoring for Radionuclides and Metals in Central Asia Rivers. Sampling and Analysis Plan and Operational Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Passell, Howard D.; Barber, David S.; Betsill, J. David

    2002-04-02

    The transboundary nature of water resources demands a transboundary approach to their monitoring and management. However, transboundary water projects raise a challenging set of problems related to communication issues, and standardization of sampling, analysis and data management methods. This manual addresses those challenges and provides the information and guidance needed to perform the Navruz Project, a cooperative, transboundary, river monitoring project involving rivers and institutions in Kazakhstan, Kyrgyzstan, Tajikistan, and Uzbekistan facilitated by Sandia National Laboratories in the U.S. The Navruz Project focuses on waterborne radionuclides and metals because of their importance to public health and nuclear materials proliferation concernsmore » in the region. This manual provides guidelines for participants on sample and data collection, field equipment operations and procedures, sample handling, laboratory analysis, and data management. Also included are descriptions of rivers, sampling sites and parameters on which data are collected. Data obtained in this project are shared among all participating countries and the public through an internet web site, and are available for use in further studies and in regional transboundary water resource management efforts. Overall, the project addresses three main goals: to help increase capabilities in Central Asian nations for sustainable water resources management; to provide a scientific basis for supporting nuclear transparency and non-proliferation in the region; and to help reduce the threat of conflict in Central Asia over water resources, proliferation concerns, or other factors.« less

  6. Evaluation of the Human/Extreme Environment Interaction: Implications for Enhancing Operational Performance and Recovery

    DTIC Science & Technology

    2012-10-01

    saturation was evaluated before and after exercise, and during recovery at 0:30, 2:30, 4:30, and 6:00 using a pulse oximeter (Nonin Onyx II 9550, Plymouth...Each collection was collected for 5 min, with the last 3 min averaged to represent the sample period. Pulse Oximetry. Blood oxygen ...would lead to more ATP per molecule of oxygen . The paradox with short-term and long-term metabolic adaptations is yet to be completely understood

  7. Runtime optimization of an application executing on a parallel computer

    DOEpatents

    None

    2014-11-25

    Identifying a collective operation within an application executing on a parallel computer; identifying a call site of the collective operation; determining whether the collective operation is root-based; if the collective operation is not root-based: establishing a tuning session and executing the collective operation in the tuning session; if the collective operation is root-based, determining whether all compute nodes executing the application identified the collective operation at the same call site; if all compute nodes identified the collective operation at the same call site, establishing a tuning session and executing the collective operation in the tuning session; and if all compute nodes executing the application did not identify the collective operation at the same call site, executing the collective operation without establishing a tuning session.

  8. Runtime optimization of an application executing on a parallel computer

    DOEpatents

    Faraj, Daniel A; Smith, Brian E

    2014-11-18

    Identifying a collective operation within an application executing on a parallel computer; identifying a call site of the collective operation; determining whether the collective operation is root-based; if the collective operation is not root-based: establishing a tuning session and executing the collective operation in the tuning session; if the collective operation is root-based, determining whether all compute nodes executing the application identified the collective operation at the same call site; if all compute nodes identified the collective operation at the same call site, establishing a tuning session and executing the collective operation in the tuning session; and if all compute nodes executing the application did not identify the collective operation at the same call site, executing the collective operation without establishing a tuning session.

  9. Runtime optimization of an application executing on a parallel computer

    DOEpatents

    Faraj, Daniel A.; Smith, Brian E.

    2013-01-29

    Identifying a collective operation within an application executing on a parallel computer; identifying a call site of the collective operation; determining whether the collective operation is root-based; if the collective operation is not root-based: establishing a tuning session and executing the collective operation in the tuning session; if the collective operation is root-based, determining whether all compute nodes executing the application identified the collective operation at the same call site; if all compute nodes identified the collective operation at the same call site, establishing a tuning session and executing the collective operation in the tuning session; and if all compute nodes executing the application did not identify the collective operation at the same call site, executing the collective operation without establishing a tuning session.

  10. Nutrition: blood sample collection

    NASA Image and Video Library

    2007-03-20

    ISS014-E-17550 (20 March 2007) --- Astronaut Michael E. Lopez-Alegria, Expedition 14 commander and NASA space station science officer, prepares to insert a test sample in the Minus Eighty Degree Laboratory Freezer for ISS (MELFI) as part of the Nutritional Status Assessment (NUTRITION) experiment in the Destiny laboratory of the International Space Station. MELFI is a low temperature freezer facility with nominal operating temperatures of -80, -26 and +4 degrees Celsius that will preserve experiment materials over long periods.

  11. Nutrition: blood sample collection

    NASA Image and Video Library

    2007-03-20

    ISS014-E-17547 (20 March 2007) --- Astronaut Michael E. Lopez-Alegria, Expedition 14 commander and NASA space station science officer, prepares to insert a test sample in the Minus Eighty Degree Laboratory Freezer for ISS (MELFI) as part of the Nutritional Status Assessment (NUTRITION) experiment in the Destiny laboratory of the International Space Station. MELFI is a low temperature freezer facility with nominal operating temperatures of -80, -26 and +4 degrees Celsius that will preserve experiment materials over long periods.

  12. Connecticut Biodiesel Power Generation Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grannis, Lee; York, Carla R.

    Sabre will continue support of the emissions equipment and VARS issues to ensure all are resolved and the system is functioning as expected. The remote data collection to become more automated. Final project reports for data collection and system performance to be generated. Sabre continued to support the emissions equipment and VARS issues to ensure all are resolved and the system is functioning as expected. The remote data collection became more automated. Final project reports for data collection and system performance were generated and are part of this final report. Some Systems Sensors were replaced due to a lightning strike.more » Sample data charts are shown at the end of the report. During the project, Sabre Engineering provided support to the project team with regarding to troubleshooting technical issues and system integration with the local power utility company. The resulting lessons learned through Sabre’s participation in the project have been valuable to the integrity of the data collected as well as in providing BioPur Light & Power valuable insights into future operations and planning for possible expansion. The system monitoring and data collection system has been operating as designed and continues to provide relevant information to the system operators. The information routinely gathered automatically by the system also contributes to the REN and REC validations which are required to secure credit for these items. During the quarter, the remaining work on the operations and safety manual were completed and released for publication after screen shots were verified. The goal of this effort to provide an accurate set of precautions and procedures for the technology system that can be replicated to other similar system.« less

  13. Effects of floodgates operation on nitrogen transformation in a lake based on structural equation modeling analysis.

    PubMed

    Zhu, Longji; Zhou, Haixuan; Xie, Xinyu; Li, Xueke; Zhang, Duoying; Jia, Liming; Wei, Qingbin; Zhao, Yue; Wei, Zimin; Ma, Yingying

    2018-08-01

    Floodgates operation is one of the primary means of flood control in lake development. However, knowledge on the linkages between floodgates operation and nitrogen transformation during the flood season is limited. In this study, water samples from six sampling sites along Lake Xingkai watershed were collected before and after floodgates operation. The causal relationships between environmental factors, bacterioplankton community composition and nitrogen fractions were determined during flood season. We found that concentrations of nitrogen fractions decreased significantly when the floodgates were opened, while the concentrations of total nitrogen (TN) and NO 3 - increased when the floodgates had been shut for a period. Further, we proposed a possible mechanism that the influence of floodgates operation on nitrogen transformation was largely mediated through changes in dissolved organic matter, dissolved oxygen and bacterioplankton community composition as revealed by structural equation modeling (SEM). We conclude that floodgates operation has a high risk for future eutrophication of downstream watershed, although it can reduce nitrogen content temporarily. Therefore, the environmental impacts of floodgates operation should be carefully evaluated before the floodwaters were discharged into downstream watershed. Copyright © 2018. Published by Elsevier B.V.

  14. Drinking Water Microbiome as a Screening Tool for ...

    EPA Pesticide Factsheets

    Many water utilities in the US using chloramine as disinfectant treatment in their distribution systems have experienced nitrification episodes, which detrimentally impact the water quality. A chloraminated drinking water distribution system (DWDS) simulator was operated through four successive operational schemes, including two stable events (SS) and an episode of nitrification (SF), followed by a ‘chlorine burn’ (SR) by switching disinfectant from chloramine to free chlorine. The current research investigated the viability of biological signatures as potential indicators of operational failure and predictors of nitrification in DWDS. For this purpose, we examined the bulk water (BW) bacterial microbiome of a chloraminated DWDS simulator operated through successive operational schemes, including an episode of nitrification. BW data was chosen because sampling of BW in a DWDS by water utility operators is relatively simpler and easier than collecting biofilm samples from underground pipes. The methodology applied a supervised classification machine learning approach (naïve Bayes algorithm) for developing predictive models for nitrification. Classification models were trained with biological datasets (Operational Taxonomic Unit [OTU] and genus-level taxonomic groups) generated using next generation high-throughput technology, and divided into two groups (i.e. binary) of positives and negatives (Failure and Stable, respectively). We also invest

  15. Hematocrit-Independent Quantitation of Stimulants in Dried Blood Spots: Pipet versus Microfluidic-Based Volumetric Sampling Coupled with Automated Flow-Through Desorption and Online Solid Phase Extraction-LC-MS/MS Bioanalysis.

    PubMed

    Verplaetse, Ruth; Henion, Jack

    2016-07-05

    A workflow overcoming microsample collection issues and hematocrit (HCT)-related bias would facilitate more widespread use of dried blood spots (DBS). This report describes comparative results between the use of a pipet and a microfluidic-based sampling device for the creation of volumetric DBS. Both approaches were successfully coupled to HCT-independent, fully automated sample preparation and online liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) analysis allowing detection of five stimulants in finger prick blood. Reproducible, selective, accurate, and precise responses meeting generally accepted regulated bioanalysis guidelines were observed over the range of 5-1000 ng/mL whole blood. The applied heated flow-through solvent desorption of the entire spot and online solid phase extraction (SPE) procedure were unaffected by the blood's HCT value within the tested range of 28.0-61.5% HCT. Enhanced stability for mephedrone on DBS compared to liquid whole blood was observed. Finger prick blood samples were collected using both volumetric sampling approaches over a time course of 25 h after intake of a single oral dose of phentermine. A pharmacokinetic curve for the incurred phentermine was successfully produced using the described validated method. These results suggest that either volumetric sample collection method may be amenable to field-use followed by fully automated, HCT-independent DBS-SPE-LC-MS/MS bioanalysis for the quantitation of these representative controlled substances. Analytical data from DBS prepared with a pipet and microfluidic-based sampling devices were comparable, but the latter is easier to operate, making this approach more suitable for sample collection by unskilled persons.

  16. Experimental Study of Arcing on High-voltage Solar Arrays

    NASA Technical Reports Server (NTRS)

    Vayner, Boris; Galofaro, Joel; Ferguson, Dale

    2005-01-01

    The main obstacle to the implementation of a high-voltage solar array in space is arcing on the conductor-dielectric junctions exposed to the surrounding plasma. One obvious solution to this problem would be the installation of fully encapsulated solar arrays which were not having exposed conductors at all. However, there are many technological difficulties that must be overcome before the employment of fully encapsulated arrays will turn into reality. An alternative solution to raise arc threshold by modifications of conventionally designed solar arrays looks more appealing, at least in the nearest future. A comprehensive study of arc inception mechanism [1-4] suggests that such modifications can be done in the following directions: i) to insulate conductor-dielectric junction from a plasma environment (wrapthrough interconnects); ii) to change a coverglass geometry (overhang); iii) to increase a coverglass thickness; iiii) to outgas areas of conductor-dielectric junctions. The operation of high-voltage array in LEO produces also the parasitic current power drain on the electrical system. Moreover, the current collected from space plasma by solar arrays determines the spacecraft floating potential that is very important for the design of spacecraft and its scientific apparatus. In order to verify the validity of suggested modifications and to measure current collection five different solar array samples have been tested in large vacuum chamber. Each sample (36 silicon based cells) consists of three strings containing 12 cells connected in series. Thus, arc rate and current collection can be measured on every string independently, or on a whole sample when strings are connected in parallel. The heater installed in the chamber provides the possibility to test samples under temperature as high as 80 C that simulates the LEO operational temperature. The experimental setup is described below.

  17. Experimental Study of Arcing on High-Voltage Solar Arrays

    NASA Technical Reports Server (NTRS)

    Vayner, Boris; Galofaro, Joel; Ferguson, Dale

    2003-01-01

    The main obstacle to the implementation of a high-voltage solar array in space is arcing on the conductor-dielectric junctions exposed to the surrounding plasma. One obvious solution to this problem would be the installation of fully encapsulated solar arrays which were not having exposed conductors at all. However, there are many technological difficulties that must be overcome before the employment of fully encapsulated arrays will turn into reality. An alternative solution to raise arc threshold by modifications of conventionally designed solar arrays looks more appealing, at least in the nearest future. A comprehensive study of arc inception mechanism suggests that such modifications can be done in the following directions: 1) To insulate conductor-dielectric junction from a plasma environment (wrapthrough interconnects); 2) To change a coverglass geometry (overhang); 3) To increase a coverglass thickness; 4) To outgas areas of conductor-dielectric junctions. The operation of high-voltage array in LEO produces also the parasitic current power drain on the electrical system. Moreover, the current collected from space plasma by solar arrays determines the spacecraft floating potential that is very important for the design of spacecraft and its scientific apparatus. In order to verify the validity of suggested modifications and to measure current collection five different solar array samples have been tested in a large vacuum chamber. Each sample (36 silicon based cells) consists of three strings containing 12 cells connected in series. Thus, arc rate and current collection can be measured on every string independently, or on a whole sample when strings are connected in parallel. The heater installed in the chamber provides the possibility to test samples under temperature as high as 80 C that stimulates the LEO operational temperature. The experimental setup is described below.

  18. Optimizing Sampling Efficiency for Biomass Estimation Across NEON Domains

    NASA Astrophysics Data System (ADS)

    Abercrombie, H. H.; Meier, C. L.; Spencer, J. J.

    2013-12-01

    Over the course of 30 years, the National Ecological Observatory Network (NEON) will measure plant biomass and productivity across the U.S. to enable an understanding of terrestrial carbon cycle responses to ecosystem change drivers. Over the next several years, prior to operational sampling at a site, NEON will complete construction and characterization phases during which a limited amount of sampling will be done at each site to inform sampling designs, and guide standardization of data collection across all sites. Sampling biomass in 60+ sites distributed among 20 different eco-climatic domains poses major logistical and budgetary challenges. Traditional biomass sampling methods such as clip harvesting and direct measurements of Leaf Area Index (LAI) involve collecting and processing plant samples, and are time and labor intensive. Possible alternatives include using indirect sampling methods for estimating LAI such as digital hemispherical photography (DHP) or using a LI-COR 2200 Plant Canopy Analyzer. These LAI estimations can then be used as a proxy for biomass. The biomass estimates calculated can then inform the clip harvest sampling design during NEON operations, optimizing both sample size and number so that standardized uncertainty limits can be achieved with a minimum amount of sampling effort. In 2011, LAI and clip harvest data were collected from co-located sampling points at the Central Plains Experimental Range located in northern Colorado, a short grass steppe ecosystem that is the NEON Domain 10 core site. LAI was measured with a LI-COR 2200 Plant Canopy Analyzer. The layout of the sampling design included four, 300 meter transects, with clip harvests plots spaced every 50m, and LAI sub-transects spaced every 10m. LAI was measured at four points along 6m sub-transects running perpendicular to the 300m transect. Clip harvest plots were co-located 4m from corresponding LAI transects, and had dimensions of 0.1m by 2m. We conducted regression analyses with LAI and clip harvest data to determine whether LAI can be used as a suitable proxy for aboveground standing biomass. We also compared optimal sample sizes derived from LAI data, and clip-harvest data from two different size clip harvest areas (0.1m by 1m vs. 0.1m by 2m). Sample sizes were calculated in order to estimate the mean to within a standardized level of uncertainty that will be used to guide sampling effort across all vegetation types (i.e. estimated within × 10% with 95% confidence). Finally, we employed a Semivariogram approach to determine optimal sample size and spacing.

  19. The use of bulk collectors in monitoring wet deposition at high-altitude sites in winter

    USGS Publications Warehouse

    Ranalli, A.J.; Turk, J.T.; Campbell, D.H.

    1997-01-01

    Concentrations of dissolved ions from samples collected by wet/dry collectors were compared to those collected by bulk collectors at Halfmoon Creek and Ned Wilson Lake in western Colorado to determine if bulk collectors can be used to monitor wet deposition chemistry in remote, high-altitude regions in winter. Hydrogen-ion concentration was significantly lower (p 0.05) at Halfmoon Creek. Wet deposition concentrations were predicated from bulk deposition concentrations through linear regression analysis. Results indicate that anions (chloride, nitrate and sulfate) can be predicted with a high degree of confidence. Lack of significant differences between seasonal (winter and summer) ratios of bulk to wet deposition concentrations indicates that at sites where operation of a wet/dry collector during the winter is not practical, wet deposition concentrations can be predicted from bulk collector samples through regression analysis of wet and bulk deposition data collected during the summer.

  20. Intercomparison of fog water samplers

    NASA Astrophysics Data System (ADS)

    Schell, Dieter; Georgii, Hans-Walter; Maser, Rolf; Jaeschke, Wolfgang; Arends, Beate G.; Kos, Gerard P. A.; Winkler, Peter; Schneider, Thomas; Berner, Axel; Kruisz, Christian

    1992-11-01

    During the Po Valley Fog Experiment 1989, two fogwater collectors were operated simultaneously at the ground and the results were compared to each other. The chemical analyses of the samples as well as the collection efficiencies showed remarkable differences between both collectors. Some differences in the solute concentrations in the samples of both collectors could be expected due to small differences in the 50-percent cut-off diameters. The large differences in the collection efficiencies however cannot be explained by these small variations of d sub 50, because normally only a small fraction of the water mass is concentrated in the size range of 5-7-micron droplets. It is shown that it is not sufficient to characterize a fogwater collector only by its cut-off diameter. The results of several wind tunnel calibration tests show that the collection efficiencies of the fogwater collectors are a function of windspeed and shape of the droplet spectra.

  1. Exposure science in U.S. military operations: a review.

    PubMed

    Martin, Nicholas J; Richards, Erin E; Kirkpatrick, Jeffrey S

    2011-07-01

    Since 1991, the U.S. Department of Defense has conducted deployment occupational and environmental health surveillance activities in the geographic combatant commands for major conflicts, military exercises, and humanitarian and peace-building missions. The DoD has made significant improvements in documenting and assessing deployment environmental hazards and threats since 1991, illustrated by accomplishments in Bosnia, Kosovo, and Operations Noble Eagle (following the September 11, 2001 terrorist attacks); Enduring Freedom-Afghanistan; and Iraqi Freedom (2003-2010). Sampling is now recommended as part of the DoD Exposure Assessment Method, a dynamic process that is performed during all phases of military operations: I--Predeployment, II--Mobilization, III--Conflict, and IV-Postdeployment. From 2001 to 2009, deployed personnel collected over 24,500 air, water, soil, and bulk samples during operations. These efforts have lead to the creation of an environmental health surveillance database that has been used to investigate public health issues. However, gaps exist, especially in the assessment of individual exposures during deployment.

  2. EVA Swab Tool to Support Planetary Protection and Astrobiology Evaluations

    NASA Technical Reports Server (NTRS)

    Rucker, Michelle A.; Hood, Drew; Walker, Mary; Venkateswaran, Kasthuri J.; Schuerger, Andrew C.

    2018-01-01

    When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed systems meet planetary protection requirements-and to protect our science from human contamination-we'll need to assess whether microorganisms may be leaking or venting from our spacecraft. Microbial sample collection outside of a pressurized spacecraft is complicated by temperature extremes, low pressures that preclude the use of laboratory standard (wetted) swabs, and operation either in bulky spacesuits or with robotic assistance. Engineers at the National Aeronautics and Space Administration (NASA) recently developed a swab kit for use in collecting microbial samples from the external surfaces of crewed spacecraft, including spacesuits. The Extravehicular Activity (EVA) Swab Kit consists of a single swab tool handle and an eight-canister sample caddy. The design team minimized development cost by re-purposing a heritage Space Shuttle tile repair handle that was designed to quickly snap into different tool attachments by engaging a mating device in each attachment. This allowed the tool handle to snap onto a fresh swab attachment much like popular shaving razor handles can snap onto a disposable blade cartridge. To disengage the handle from a swab, the user performs two independent functions, which can be done with a single hand. This dual operation mitigates the risk that a swab will be inadvertently released and lost in microgravity. Each swab attachment is fitted with commercially available foam swab tips, vendor-certified to be sterile for Deoxyribonucleic Acid (DNA). A microbial filter installed in the bottom of each sample container allows the container to outgas and repressurize without introducing microbial contaminants to internal void spaces. Extensive ground testing, post-test handling, and sample analysis confirmed the design is able to maintain sterile conditions as the canister moves between various pressure environments. To further minimize cost, the design team acquired extensive ground test experience in a relevant flight environment by piggy-backing onto suited crew training runs. These training runs allowed the project to validate tool interfaces with pressurized EVA gloves and collect user feedback on the tool design and function, as well as characterize baseline microbial data for different types of spacesuits. In general, test subjects found the EVA Swab Kit relatively straightforward to operate, but identified a number of design improvements that will be incorporated into the final design. Although originally intended to help characterize human forward contaminants, this tool has other potential applications, such as for collecting and preserving space-exposed materials to support astrobiology experiments.

  3. Observations and Modeling of the Green Ocean Amazon 2014/15: Transmission Electron Microscopy Analysis of Aerosol Particles Field Campaign Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buseck, Peter

    2016-03-01

    During two Intensive Operational Periods (IOP), we collected samples at 3-hour intervals for transmission electron microscopy analysis. The resulting transmission electron microscopy images and compositions were analyzed for the samples of interest. Further analysis will be done especially for the plume of interest. We found solid spherical organic particles from rebounded samples collected with Professor Scot Martin’s group (Harvard University). Approximately 30% of the rebounded particles at 95% relative humidity were spherical organic particles. Their sources and formation process are not known, but such spherical particles could be solid and will have heterogeneous chemical reactions. We observed many organic particlesmore » that are internally mixed with inorganic elements such as potassium and nitrogen. They are either homogeneously mixed or have inorganic cores with organic aerosol coatings. Samples collected from the Manaus, Brazil, pollution plume included many nano-size soot particles mixed with organic material and sulfate. Aerosol particles from clean periods included organic aerosol particles, sulfate, sea salt, dust, and primary biogenic aerosol particles. There was more dust, primary biogenic aerosol, and tar balls in samples taken during IOP1 than those taken during IOP2. Many dust particles were found between March 2 and 3.« less

  4. Autonomous microfluidic sample preparation system for protein profile-based detection of aerosolized bacterial cells and spores.

    PubMed

    Stachowiak, Jeanne C; Shugard, Erin E; Mosier, Bruce P; Renzi, Ronald F; Caton, Pamela F; Ferko, Scott M; Van de Vreugde, James L; Yee, Daniel D; Haroldsen, Brent L; VanderNoot, Victoria A

    2007-08-01

    For domestic and military security, an autonomous system capable of continuously monitoring for airborne biothreat agents is necessary. At present, no system meets the requirements for size, speed, sensitivity, and selectivity to warn against and lead to the prevention of infection in field settings. We present a fully automated system for the detection of aerosolized bacterial biothreat agents such as Bacillus subtilis (surrogate for Bacillus anthracis) based on protein profiling by chip gel electrophoresis coupled with a microfluidic sample preparation system. Protein profiling has previously been demonstrated to differentiate between bacterial organisms. With the goal of reducing response time, multiple microfluidic component modules, including aerosol collection via a commercially available collector, concentration, thermochemical lysis, size exclusion chromatography, fluorescent labeling, and chip gel electrophoresis were integrated together to create an autonomous collection/sample preparation/analysis system. The cycle time for sample preparation was approximately 5 min, while total cycle time, including chip gel electrophoresis, was approximately 10 min. Sensitivity of the coupled system for the detection of B. subtilis spores was 16 agent-containing particles per liter of air, based on samples that were prepared to simulate those collected by wetted cyclone aerosol collector of approximately 80% efficiency operating for 7 min.

  5. Mutagenicity of biodiesel or diesel exhaust particles and the effect of engine operating conditions.

    PubMed

    Kisin, Elena R; Shi, X C; Keane, Michael J; Bugarski, Aleksandar B; Shvedova, Anna A

    2013-03-01

    Changing the fuel supply from petroleum based ultra-low sulfur diesel (ULSD) to biodiesel and its blends is considered by many to be a viable option for controlling exposures to particulate material (PM). This is critical in the mining industry where approximately 28,000 underground miners are potentially exposed to relatively high concentrations of diesel particulate matter (DPM). This study was conducted to investigate the mutagenic potential of diesel engine emissions (DEE) from neat (B100) and blended (B50) soy-based fatty acid methyl ester (FAME) biodiesel in comparison with ULSD PM using different engine operating conditions and exhaust aftertreatment configurations. The DPM samples were collected for engine equipped with either a standard muffler or a combination of the muffler and diesel oxidation catalytic converter (DOC) that was operated at four different steady-state modes. Bacterial gene mutation activity of DPM was tested on the organic solvent extracts using the Ames Salmonella assay. The results indicate that mutagenic activity of DPM was strongly affected by fuels, engine operating conditions, and exhaust aftertreatment systems. The mutagenicity was increased with the fraction of biodiesel in the fuel. While the mutagenic activity was observed in B50 and B100 samples collected from both light-and heavy-load operating conditions, the ULSD samples were mutagenic only at light-load conditions. The presence of DOC in the exhaust system resulted in the decreased mutagenicity when engine was fueled with B100 and B50 and operated at light-load conditions. This was not the case when engine was fueled with ULSD. Heavy-load operating condition in the presence of DOC resulted in a decrease of mutagenicity only when engine was fueled with B50, but not B100 or ULSD. Therefore, the results indicate that DPM from neat or blended biodiesel has a higher mutagenic potency than that one of ULSD. Further research is needed to investigate the health effect of biodiesel as well as efficiency of DOC or other exhaust aftertreatment systems.

  6. Mutagenicity of biodiesel or diesel exhaust particles and the effect of engine operating conditions

    PubMed Central

    Kisin, Elena R; Shi, X.C; Keane, Michael J; Bugarski, Aleksandar B; Shvedova, Anna A

    2015-01-01

    Background Changing the fuel supply from petroleum based ultra-low sulfur diesel (ULSD) to biodiesel and its blends is considered by many to be a viable option for controlling exposures to particulate material (PM). This is critical in the mining industry where approximately 28,000 underground miners are potentially exposed to relatively high concentrations of diesel particulate matter (DPM). This study was conducted to investigate the mutagenic potential of diesel engine emissions (DEE) from neat (B100) and blended (B50) soy-based fatty acid methyl ester (FAME) biodiesel in comparison with ULSD PM using different engine operating conditions and exhaust aftertreatment configurations. Methods The DPM samples were collected for engine equipped with either a standard muffler or a combination of the muffler and diesel oxidation catalytic converter (DOC) that was operated at four different steady-state modes. Bacterial gene mutation activity of DPM was tested on the organic solvent extracts using the Ames Salmonella assay. Results The results indicate that mutagenic activity of DPM was strongly affected by fuels, engine operating conditions, and exhaust aftertreatment systems. The mutagenicity was increased with the fraction of biodiesel in the fuel. While the mutagenic activity was observed in B50 and B100 samples collected from both light-and heavy-load operating conditions, the ULSD samples were mutagenic only at light-load conditions. The presence of DOC in the exhaust system resulted in the decreased mutagenicity when engine was fueled with B100 and B50 and operated at light-load conditions. This was not the case when engine was fueled with ULSD. Heavy-load operating condition in the presence of DOC resulted in a decrease of mutagenicity only when engine was fueled with B50, but not B100 or ULSD. Conclusions Therefore, the results indicate that DPM from neat or blended biodiesel has a higher mutagenic potency than that one of ULSD. Further research is needed to investigate the health effect of biodiesel as well as efficiency of DOC or other exhaust aftertreatment systems. PMID:26457185

  7. Reducing power consumption while performing collective operations on a plurality of compute nodes

    DOEpatents

    Archer, Charles J [Rochester, MN; Blocksome, Michael A [Rochester, MN; Peters, Amanda E [Rochester, MN; Ratterman, Joseph D [Rochester, MN; Smith, Brian E [Rochester, MN

    2011-10-18

    Methods, apparatus, and products are disclosed for reducing power consumption while performing collective operations on a plurality of compute nodes that include: receiving, by each compute node, instructions to perform a type of collective operation; selecting, by each compute node from a plurality of collective operations for the collective operation type, a particular collective operation in dependence upon power consumption characteristics for each of the plurality of collective operations; and executing, by each compute node, the selected collective operation.

  8. Effect of impact stress on microbial recovery on an agar surface.

    PubMed Central

    Stewart, S L; Grinshpun, S A; Willeke, K; Terzieva, S; Ulevicius, V; Donnelly, J

    1995-01-01

    Microbial stress due to the impaction of microorganisms onto an agar collection surface was studied experimentally. The relative recovery rates of aerosolized Pseudomonas fluorescens and Micrococcus luteus were determined as a function of the impaction velocity by using a moving agar slide impactor operating over a flow rate range from 3.8 to 40 liters/min yielding impaction velocities from 24 to 250 m/s. As a reference, the sixth stage of the Andersen Six-Stage Viable Particle Sizing Sampler was used at its operating flow rate of 28.3 liters/min (24 m/s). At a collection efficiency of close to 100% for the agar slide impactor, an increase in sampling flow rate and, therefore, in impaction velocity produced a significant decline in the percentage of microorganisms recovered. Conversely, when the collection efficiency was less than 100%, greater recovery and lower injury rates occurred. The highest relative rate of recovery (approximately 51% for P. fluorescens and approximately 62% for M. luteus) was obtained on the complete (Trypticase soy agar) medium at 40 and 24 m/s (6.4 and 3.8 liters/min), respectively. M. luteus demonstrated less damage than P. fluorescens, suggesting the hardy nature of the gram-positive strain versus that of the gram-negative microorganism. Comparison of results from the agar slide and Andersen impactors at the same sampling velocity showed that recovery and injury due to collection depends not only on the magnitude of the impaction velocity but also on the degree to which the microorganisms may be embedded in the collection medium.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7747946

  9. Standardizing operational vector sampling techniques for measuring malaria transmission intensity: evaluation of six mosquito collection methods in western Kenya.

    PubMed

    Wong, Jacklyn; Bayoh, Nabie; Olang, George; Killeen, Gerry F; Hamel, Mary J; Vulule, John M; Gimnig, John E

    2013-04-30

    Operational vector sampling methods lack standardization, making quantitative comparisons of malaria transmission across different settings difficult. Human landing catch (HLC) is considered the research gold standard for measuring human-mosquito contact, but is unsuitable for large-scale sampling. This study assessed mosquito catch rates of CDC light trap (CDC-LT), Ifakara tent trap (ITT), window exit trap (WET), pot resting trap (PRT), and box resting trap (BRT) relative to HLC in western Kenya to 1) identify appropriate methods for operational sampling in this region, and 2) contribute to a larger, overarching project comparing standardized evaluations of vector trapping methods across multiple countries. Mosquitoes were collected from June to July 2009 in four districts: Rarieda, Kisumu West, Nyando, and Rachuonyo. In each district, all trapping methods were rotated 10 times through three houses in a 3 × 3 Latin Square design. Anophelines were identified by morphology and females classified as fed or non-fed. Anopheles gambiae s.l. were further identified as Anopheles gambiae s.s. or Anopheles arabiensis by PCR. Relative catch rates were estimated by negative binomial regression. When data were pooled across all four districts, catch rates (relative to HLC indoor) for An. gambiae s.l (95.6% An. arabiensis, 4.4% An. gambiae s.s) were high for HLC outdoor (RR = 1.01), CDC-LT (RR = 1.18), and ITT (RR = 1.39); moderate for WET (RR = 0.52) and PRT outdoor (RR = 0.32); and low for all remaining types of resting traps (PRT indoor, BRT indoor, and BRT outdoor; RR < 0.08 for all). For Anopheles funestus, relative catch rates were high for ITT (RR = 1.21); moderate for HLC outdoor (RR = 0.47), CDC-LT (RR = 0.69), and WET (RR = 0.49); and low for all resting traps (RR < 0.02 for all). At finer geographic scales, however, efficacy of each trap type varied from district to district. ITT, CDC-LT, and WET appear to be effective methods for large-scale vector sampling in western Kenya. Ultimately, choice of collection method for operational surveillance should be driven by trap efficacy and scalability, rather than fine-scale precision with respect to HLC. When compared with recent, similar trap evaluations in Tanzania and Zambia, these data suggest that traps which actively lure host-seeking females will be most useful for surveillance in the face of declining vector densities.

  10. BioDry: An Inexpensive, Low-Power Method to Preserve Aquatic Microbial Biomass at Room Temperature.

    PubMed

    Tuorto, Steven J; Brown, Chris M; Bidle, Kay D; McGuinness, Lora R; Kerkhof, Lee J

    2015-01-01

    This report describes BioDry (patent pending), a method for reliably preserving the biomolecules associated with aquatic microbial biomass samples, without the need of hazardous materials (e.g. liquid nitrogen, preservatives, etc.), freezing, or bulky storage/sampling equipment. Gel electrophoresis analysis of nucleic acid extracts from samples treated in the lab with the BioDry method indicated that molecular integrity was protected in samples stored at room temperature for up to 30 days. Analysis of 16S/18S rRNA genes for presence/absence and relative abundance of microorganisms using both 454-pyrosequencing and TRFLP profiling revealed statistically indistinguishable communities from control samples that were frozen in liquid nitrogen immediately after collection. Seawater and river water biomass samples collected with a portable BioDry "field unit", constructed from off-the-shelf materials and a battery-operated pumping system, also displayed high levels of community rRNA preservation, despite a slight decrease in nucleic acid recovery over the course of storage for 30 days. Functional mRNA and protein pools from the field samples were also effectively conserved with BioDry, as assessed by respective RT-PCR amplification and western blot of ribulose-1-5-bisphosphate carboxylase/oxygenase. Collectively, these results demonstrate that BioDry can adequately preserve a suite of biomolecules from aquatic biomass at ambient temperatures for up to a month, giving it great potential for high resolution sampling in remote locations or on autonomous platforms where space and power are limited.

  11. BioDry: An Inexpensive, Low-Power Method to Preserve Aquatic Microbial Biomass at Room Temperature

    PubMed Central

    Tuorto, Steven J.; Brown, Chris M.; Bidle, Kay D.; McGuinness, Lora R.; Kerkhof, Lee J.

    2015-01-01

    This report describes BioDry (patent pending), a method for reliably preserving the biomolecules associated with aquatic microbial biomass samples, without the need of hazardous materials (e.g. liquid nitrogen, preservatives, etc.), freezing, or bulky storage/sampling equipment. Gel electrophoresis analysis of nucleic acid extracts from samples treated in the lab with the BioDry method indicated that molecular integrity was protected in samples stored at room temperature for up to 30 days. Analysis of 16S/18S rRNA genes for presence/absence and relative abundance of microorganisms using both 454-pyrosequencing and TRFLP profiling revealed statistically indistinguishable communities from control samples that were frozen in liquid nitrogen immediately after collection. Seawater and river water biomass samples collected with a portable BioDry “field unit", constructed from off-the-shelf materials and a battery-operated pumping system, also displayed high levels of community rRNA preservation, despite a slight decrease in nucleic acid recovery over the course of storage for 30 days. Functional mRNA and protein pools from the field samples were also effectively conserved with BioDry, as assessed by respective RT-PCR amplification and western blot of ribulose-1-5-bisphosphate carboxylase/oxygenase. Collectively, these results demonstrate that BioDry can adequately preserve a suite of biomolecules from aquatic biomass at ambient temperatures for up to a month, giving it great potential for high resolution sampling in remote locations or on autonomous platforms where space and power are limited. PMID:26710122

  12. DNA identification of human remains in Disaster Victim Identification (DVI): An efficient sampling method for muscle, bone, bone marrow and teeth.

    PubMed

    de Boer, Hans H; Maat, George J R; Kadarmo, D Aji; Widodo, Putut T; Kloosterman, Ate D; Kal, Arnoud J

    2018-06-04

    In disaster victim identification (DVI), DNA profiling is considered to be one of the most reliable and efficient means to identify bodies or separated body parts. This requires a post mortem DNA sample, and an ante mortem DNA sample of the presumed victim or their biological relative(s). Usually the collection of an adequate ante mortem sample is technically simple, but the acquisition of a good quality post mortem sample under unfavourable DVI circumstances is complicated due to the variable degree of preservation of the human remains and the high risk of DNA (cross) contamination. This paper provides the community with an efficient method to collect post-mortem DNA samples from muscle, bone, bone marrow and teeth, with a minimal risk of contamination. Our method has been applied in a recent, challenging DVI operation (i.e. the identification of the 298 victims of the MH17 airplane crash in 2014). 98,2% of the collected PM samples provided the DVI team with highly informative DNA genotyping results without the risk of contamination and consequent mistyping the victim's DNA. Moreover, the method is easy, cheap and quick. This paper provides the DVI community with a step-wise instructions with recommendations for the type of tissue to be sampled and the site of excision (preferably the upper leg). Although initially designed for DVI purposes, the method is also suited for the identification of individual victims. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Molecular characterization of viable Legionella spp. in cooling tower water samples by combined use of ethidium monoazide and PCR.

    PubMed

    Inoue, Hiroaki; Fujimura, Reiko; Agata, Kunio; Ohta, Hiroyuki

    2015-01-01

    Viable Legionella spp. in environmental water samples were characterized phylogenetically by a clone library analysis combining the use of ethidium monoazide and quantitative PCR. To examine the diversity of Legionella spp., six cooling tower water samples and three bath water samples were collected and analyzed. A total of 617 clones were analyzed for their 16S rRNA gene sequences and classified into 99 operational taxonomic units (OTUs). The majority of OTUs were not clustered with currently described Legionella spp., suggesting the wide diversity of not-yet-cultured Legionella groups harbored in cooling tower water environments.

  14. Molecular Characterization of Viable Legionella spp. in Cooling Tower Water Samples by Combined Use of Ethidium Monoazide and PCR

    PubMed Central

    Inoue, Hiroaki; Fujimura, Reiko; Agata, Kunio; Ohta, Hiroyuki

    2015-01-01

    Viable Legionella spp. in environmental water samples were characterized phylogenetically by a clone library analysis combining the use of ethidium monoazide and quantitative PCR. To examine the diversity of Legionella spp., six cooling tower water samples and three bath water samples were collected and analyzed. A total of 617 clones were analyzed for their 16S rRNA gene sequences and classified into 99 operational taxonomic units (OTUs). The majority of OTUs were not clustered with currently described Legionella spp., suggesting the wide diversity of not-yet-cultured Legionella groups harbored in cooling tower water environments. PMID:25736979

  15. Radionuclides, Metals, and Hydrocarbons in Oil and Gas Operational Discharges and Environmental Samples Associated with Offshore Production Facilities on the Texas/Louisiana Continental Shelf with an Environmental Assessment of Metals and Hydrocarbons.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1997-06-01

    This report presents concentrations of radionuclides, metals, and hydrocarbons in samples of produced water and produced sand from oil and gas production platforms located offshore Texas and Louisiana. concentrations in produced water discharge plume / receiving water, ambient seawater, sediment, interstitial water, and marine animal tissue samples collected in the vicinity of discharging platforms and reference sites distant from discharges are also reported and discussed. An environmental risk assessment is made on the basis of the concentration of metals and hydrocarbons determined in the samples.

  16. Radionuclides, Metals, and Hydrocarbons in Oil and Gas Operational Discharges and Environmental Samples Associated with Offshore Production Facilities on the Texas/Louisiana Continental Shelf with an Environmental Assessment of Metals and Hydrocarbons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Continental Shelf Associates, Inc.

    1999-08-16

    This report presents concentrations of radionuclides, metals, and hydrocarbons in samples of produced water and produced sand from oil and gas production platforms located offshore Texas and Louisiana. Concentrations in produced water discharge plume/receiving water, ambient seawater, sediment, interstitial water, and marine animal tissue samples collected in the vicinity of discharging platforms and reference sites distant from discharges are also reported and discussed. An environmental risk assessment is made on the basis of the concentrations of metals and hydrocarbons determined in the samples.

  17. Engineering scale demonstration of a prospective Cast Stone process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cozzi, A.; Fowley, M.; Hansen, E.

    2014-09-30

    This report documents an engineering-scale demonstration with non-radioactive simulants that was performed at SRNL using the Scaled Continuous Processing Facility (SCPF) to fill an 8.5 ft container with simulated Cast Stone grout. The Cast Stone formulation was chosen from the previous screening tests. Legacy salt solution from previous Hanford salt waste testing was adjusted to correspond to the average composition generated from the Hanford Tank Waste Operation Simulator (HTWOS). The dry blend materials, ordinary portland cement (OPC), Class F fly ash, and ground granulated blast furnace slag (GGBFS or BFS), were obtained from Lafarge North America in Pasco, WA. Overmore » three days, the SCPF was used to fill a 1600 gallon container, staged outside the facility, with simulated Cast Stone grout. The container, staged outside the building approximately 60 ft from the SCPF, was instrumented with x-, y-, and z-axis thermocouples to monitor curing temperature. The container was also fitted with two formed core sampling vials. For the operation, the targeted grout production rate was 1.5 gpm. This required a salt solution flow rate of approximately 1 gpm and a premix feed rate of approximately 580 lb/h. During the final day of operation, the dry feed rate was increased to evaluate the ability of the system to handle increased throughput. Although non-steady state operational periods created free surface liquids, no bleed water was observed either before or after operations. The final surface slope at a fill height of 39.5 inches was 1-1.5 inches across the 8.5 foot diameter container, highest at the final fill point and lowest diametrically opposed to the fill point. During processing, grout was collected in cylindrical containers from both the mixer discharge and the discharge into the container. These samples were stored in a humid environment either in a closed box proximal to the container or inside the laboratory. Additional samples collected at these sampling points were analyzed for rheological properties and density. Both the rheological properties (plastic viscosity and yield strength) and density were consistent with previous and later SCPF runs.« less

  18. Multiplexed electronically programmable multimode ionization detector for chromatography

    DOEpatents

    Wise, M.B.; Buchanan, M.V.

    1988-05-19

    Method and apparatus for detecting and differentiating organic compounds based on their electron affinity. An electron capture detector cell (ECD) is operated in a plurality of multiplexed electronically programmable operating modes to alter the detector response during a single sampling cycle to acquire multiple simultaneous chromatograms corresponding to each of the different operating modes. The cell is held at a constant subatmospheric pressure while the electron collection bias voltage applied to the cell is modulated electronically to allow acquisition of multiple chromatograms for a single sample elution from a chromatograph representing three distinctly different response modes. A system is provided which automatically controls the programmed application of bias pulses at different intervals and/or amplitudes to switch the detector from an ionization mode to the electron capture mode and various degrees therebetween to provide an improved means of tuning an ECD for multimode detection and improved specificity. 6 figs.

  19. Multiplexed electronically programmable multimode ionization detector for chromatography

    DOEpatents

    Wise, Marcus B.; Buchanan, Michelle V.

    1989-01-01

    Method and apparatus for detecting and differentiating organic compounds based on their electron affinity. An electron capture detector cell (ECD) is operated in a plurality of multiplexed electroncially programmable operating modes to alter the detector response during a single sampling cycle to acquire multiple simultaneous chromatograms corresponding to each of the different operating modes. The cell is held at a constant subatmospheric pressure while the electron collection bias voltage applied to the cell is modulated electronically to allow acquisition of multiple chromatograms for a single sample elution from a chromatograph representing three distinctly different response modes. A system is provided which automatically controls the programmed application of bias pulses at different intervals and/or amplitudes to switch the detector from an ionization mode to the electron capture mode and various degrees therebetween to provide an improved means of tuning an ECD for multimode detection and improved specificity.

  20. Cruise status of Hayabusa2: Round trip mission to asteroid 162173 Ryugu

    NASA Astrophysics Data System (ADS)

    Tsuda, Yuichi; Watanabe, Sei-ichiro; Saiki, Takanao; Yoshikawa, Makoto; Nakazawa, Satoru

    2017-07-01

    The Japan Aerospace Exploration Agency launched an asteroid sample return spacecraft "Hayabusa2" on December 3, 2014 by the Japanese H2A launch vehicle. Hayabusa2 aims at the round trip mission to the asteroid 162173 Ryugu. Hayabusa2 successfully conducted the Earth gravity assist on December 3, 2015, and now the spacecraft is flying toward Ryugu with the microwave discharge ion engine as the means of propulsion. As of September 2016, 1346 h of the ion engine operation has been achieved as planned. Three touch downs/sample collections, one kinetic impact/crater generation, four surface rovers deployment and many other in-situ observations are planned in the asteroid proximity phase. The operation team will perform extensive operation practice/rehearsal using a hardware-in-the-loop simulator in the year 2017 to be ready for the asteroid arrival in the summer 2018.

  1. Atmospheric Sampling on Ascension Island Using Multirotor UAVs

    PubMed Central

    Greatwood, Colin; Richardson, Thomas S.; Freer, Jim; Thomas, Rick M.; MacKenzie, A. Rob; Brownlow, Rebecca; Lowry, David; Fisher, Rebecca E.; Nisbet, Euan G.

    2017-01-01

    As part of an NERC-funded project investigating the southern methane anomaly, a team drawn from the Universities of Bristol, Birmingham and Royal Holloway flew small unmanned multirotors from Ascension Island for the purposes of atmospheric sampling. The objective of these flights was to collect air samples from below, within and above a persistent atmospheric feature, the Trade Wind Inversion, in order to characterise methane concentrations and their isotopic composition. These parameters allow the methane in the different air masses to be tied to different source locations, which can be further analysed using back trajectory atmospheric computer modelling. This paper describes the campaigns as a whole including the design of the bespoke eight rotor aircraft and the operational requirements that were needed in order to collect targeted multiple air samples up to 2.5 km above the ground level in under 20 min of flight time. Key features of the system described include real-time feedback of temperature and humidity, as well as system health data. This enabled detailed targeting of the air sampling design to be realised and planned during the flight mission on the downward leg, a capability that is invaluable in the presence of uncertainty in the pre-flight meteorological data. Environmental considerations are also outlined together with the flight plans that were created in order to rapidly fly vertical transects of the atmosphere whilst encountering changing wind conditions. Two sampling campaigns were carried out in September 2014 and July 2015 with over one hundred high altitude sampling missions. Lessons learned are given throughout, including those associated with operating in the testing environment encountered on Ascension Island. PMID:28545231

  2. SNIFFER: An aerial platform for the plume phase of a nuclear emergency

    NASA Astrophysics Data System (ADS)

    Castelluccio, D. M.; Cisbani, E.; Frullani, S.

    2012-04-01

    When a nuclear or radiological accident results in a release of a radioactive plume, AGS (Aerial Gamma Spectrometry) systems used in many countries, equipped with passive detectors, can help in giving quantitative assessment on the radiological situation (land surface contamination level) only when the air contamination due to the passage of the travelling plume has become negligible. To overcome this limitation, the Italian Institute of Health has developed and implemented a multi purpose air sampling system based on a fixed wing aircraft, for time-effective, large areas radiological surveillance (to face radiological emergency and to support homeland security). A fixed wing aircraft (Sky Arrow 650) with the front part of the fuselage properly adapted to house the detection equipment has been equipped with a compact air sampling line where the isokinetic sampling is dynamically maintained. Aerosol is collected on a Teflon® filter positioned along the line and hosted on a rotating 4-filters disk. A complex of detectors allows radionuclide identification in the collected aerosol samples. A correlated analysis of these two detectors data allows a quantitative measurement of air as well as ground surface concentration of gamma emitting radioisotopes. Environmental sensors and a GPS receiver support the characterization of the sampling conditions and the temporal and geolocation of the acquired data. Acquisition and control system based on compact electronics and real time software that operate the sampling line actuators, guarantee the dynamical isokinetic condition, and acquire the detectors and sensor data. The system is also equipped with other sampling lines to provide information on the concentration of other chemical pollutants. Operative flights have been carried out in the last years, and performances and results are presented.

  3. Sensor-triggered sampling to determine instantaneous airborne vapor exposure concentrations.

    PubMed

    Smith, Philip A; Simmons, Michael K; Toone, Phillip

    2018-06-01

    It is difficult to measure transient airborne exposure peaks by means of integrated sampling for organic chemical vapors, even with very short-duration sampling. Selection of an appropriate time to measure an exposure peak through integrated sampling is problematic, and short-duration time-weighted average (TWA) values obtained with integrated sampling are not likely to accurately determine actual peak concentrations attained when concentrations fluctuate rapidly. Laboratory analysis for integrated exposure samples is preferred from a certainty standpoint over results derived in the field from a sensor, as a sensor user typically must overcome specificity issues and a number of potential interfering factors to obtain similarly reliable data. However, sensors are currently needed to measure intra-exposure period concentration variations (i.e., exposure peaks). In this article, the digitized signal from a photoionization detector (PID) sensor triggered collection of whole-air samples when toluene or trichloroethylene vapors attained pre-determined levels in a laboratory atmosphere generation system. Analysis by gas chromatography-mass spectrometry of whole-air samples (with both 37 and 80% relative humidity) collected using the triggering mechanism with rapidly increasing vapor concentrations showed good agreement with the triggering set point values. Whole-air samples (80% relative humidity) in canisters demonstrated acceptable 17-day storage recoveries, and acceptable precision and bias were obtained. The ability to determine exceedance of a ceiling or peak exposure standard by laboratory analysis of an instantaneously collected sample, and to simultaneously provide a calibration point to verify the correct operation of a sensor was demonstrated. This latter detail may increase the confidence in reliability of sensor data obtained across an entire exposure period.

  4. Mechanisms of antimicrobial resistant Salmonella enterica transmission associated with starling-livestock interactions.

    PubMed

    Carlson, James C; Hyatt, Doreene R; Ellis, Jeremy W; Pipkin, David R; Mangan, Anna M; Russell, Michael; Bolte, Denise S; Engeman, Richard M; DeLiberto, Thomas J; Linz, George M

    2015-08-31

    Bird-livestock interactions have been implicated as potential sources for bacteria within concentrated animal feeding operations (CAFO). European starlings (Sturnus vulgaris) in particular are known to contaminate cattle feed and water with Salmonella enterica through their fecal waste. We propose that fecal waste is not the only mechanisms through which starlings introduce S. enterica to CAFO. The goal of this study was to assess if starlings can mechanically move S. enterica. We define mechanical movement as the transportation of media containing S. enterica, on the exterior of starlings within CAFO. We collected 100 starlings and obtained external wash and gastrointestinal tract (GI) samples. We also collected 100 samples from animal pens. Within each pen we collected one cattle fecal, feed, and water trough sample. Isolates from all S. enterica positive samples were subjected to antimicrobial susceptibility testing. All sample types, including 17% of external starling wash samples, contained S. enterica. All sample types had at least one antimicrobial resistant (AMR) isolate and starling GI samples harbored multidrug resistant S. enterica. The serotypes isolated from the starling external wash samples were all found in the farm environment and 11.8% (2/17) of isolates from positive starling external wash samples were resistant to at least one class of antibiotics. This study provides evidence of a potential mechanism of wildlife introduced microbial contamination in CAFO. Mechanical movement of microbiological hazards, by starlings, should be considered a potential source of bacteria that is of concern to veterinary, environmental and public health. Published by Elsevier B.V.

  5. Proposed BioRepository platform solution for the ALS research community.

    PubMed

    Sherman, Alex; Bowser, Robert; Grasso, Daniela; Power, Breen; Milligan, Carol; Jaffa, Matthew; Cudkowicz, Merit

    2011-01-01

    ALS is a rare disorder whose cause and pathogenesis is largely unknown ( 1 ). There is a recognized need to develop biomarkers for ALS to better understand the disease, expedite diagnosis and to facilitate therapy development. Collaboration is essential to obtain a sufficient number of samples to allow statistically meaningful studies. The availability of high quality biological specimens for research purposes requires the development of standardized methods for collection, long-term storage, retrieval and distribution of specimens. The value of biological samples to scientists and clinicians correlates with the completeness and relevance of phenotypical and clinical information associated with the samples ( 2 , 3 ). While developing a secure Web-based system to manage an inventory of multi-site BioRepositories, algorithms were implemented to facilitate ad hoc parametric searches across heterogeneous data sources that contain data from clinical trials and research studies. A flexible schema for a barcode label was introduced to allow association of samples to these data. The ALSBank™ BioRepository platform solution for managing biological samples and associated data is currently deployed by the Northeast ALS Consortium (NEALS). The NEALS Consortium and the Massachusetts General Hospital (MGH) Neurology Clinical Trials Unit (NCTU) support a network of multiple BioBanks, thus allowing researchers to take advantage of a larger specimen collection than they might have at an individual institution. Standard operating procedures are utilized at all collection sites to promote common practices for biological sample integrity, quality control and associated clinical data. Utilizing this platform, we have created one of the largest virtual collections of ALS-related specimens available to investigators studying ALS.

  6. Mercury contamination in bank swallows and double-crested cormorants from the Carson River, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, R.; Brewer, R.; Peterson, S.C.

    1995-12-31

    An ecological risk assessment was performed in conjunction with a remedial investigation at the Carson River Mercury Site (CRMS) in northwestern Nevada. Large quantities of mercury used in the processing of gold and silver during mining operations in the mid to late 1800s are distributed throughout the Carson River ecosystem. Previous investigations indicated elevated levels of mercury in soil, sediment, water, and the aquatic food chain. Bird exposure to mercury was determined by measuring total mercury and monomethyl mercury in blood and feather samples from 15 unfledged double-crested cormorants (Phalacrocorax auritus), and in blood, feather, and liver samples from 18more » juvenile bank swallows (Riparia riparia) at both the CRMS and uncontaminated background locations. Monomethyl mercury accounted for 90 to 98% of the total mercury in the samples. Total mercury concentrations in bird tissues collected at the CRMS were significantly higher than at background locations. Average total mercury concentrations (wet weight) for the swallow blood, liver, and feather samples collected at the CRMS were 2.63, 3.96, and 2.01 mg/kg, respectively; compared with 0.74, 1,03, and 1.84 mg/kg, respectively at the background area. Average total mercury concentrations for cormorant samples collected at the CRMS were 17.07 mg/kg for blood, and 105.1 1 mg/kg for feathers. Cormorant samples collected at the background location had average total mercury concentrations of 0.49 mg/kg for blood and 8.99 mg/kg for feathers. Results are compared with published residue-effects levels to evaluate avian risks.« less

  7. Evaluation of diagnostic procedures for subclinical mastitis in meat-producing sheep.

    PubMed

    Clements, Archie C A; Taylor, David J; Fitzpatrick, Julie L

    2003-05-01

    Samples of foremilk were collected from 261 clinically normal glands of 150 ewes, and tested using the California mastitis test (CMT). Further samples were collected from 195 of these glands for determination of automated somatic cell counts (SCC), and from 60 of these glands for bacteriological assessment. The sensitivity and specificity of CMT for detecting samples with SCC above different threshold levels and for CMT and SCC in determining bacteriological status were evaluated using two-graph receiver operating characteristics (TG-ROC). Milk samples were obtained subsequently from ten CMT positive, and five CMT negative first- and second-lactation ewes. Samples were cultured using a variety of media, incubation temperatures and atmospheric conditions, immediately after collection, and 1 week after storage at 4 degrees C and -21 degrees C. Results suggested that CMT is best used as a diagnostic test for ovine subclinical mastitis (SCM) with a cut-off of 3 (distinct gel formation), and that automated SCC thresholds of > 1200 x 10(3) cells/ml are appropriate, especially where low prevalences are expected (e.g. < 5%). Additionally, this study showed that routine bacteriological methods were appropriate for isolation of most species of pathogen responsible for ovine SCM, but storage of samples prior to culture, either at 4 degrees C or -21 degrees C, was detrimental to the isolation of several of these organisms.

  8. Investigating the Role of Wind in the Dispersion of Heavy Metals Around Mines in Arid Regions (a Case Study from Kushk Pb-Zn Mine, Bafgh, Iran).

    PubMed

    Mokhtari, Ahmad Reza; Feiznia, Sadat; Jafari, Mohammad; Tavili, Ali; Ghaneei-Bafghi, Mohammad-Javad; Rahmany, Farah; Kerry, Ruth

    2018-03-16

    The Kushk Pb-Zn mine is located in Central Iran and it has been in operation for the last 75 years. To investigate the role of wind dispersion of heavy metal pollutants from the mine area, dust samples were collected during 1 year and topsoil samples were collected around the mine. Results showed that the topsoil is polluted with Pb and Zn to about 1500 m away from the mine. It was also found that there was not a significant difference between the metal concentrations in topsoil and dust samples. The Pb and Zn concentrations in the dust samples exceeded 200 mg kg -1 and their lateral dispersion via wind was estimated to be about 4 km away from the mine. It has been shown that a combination of mining activities and mechanical dispersion via water and wind have caused lateral movement of heavy metals in this area.

  9. Mercury accumulation in snow on the Idaho National Engineering and Environmental Laboratory and surrounding region, southeast Idaho, USA

    USGS Publications Warehouse

    Susong, D.D.; Abbott, M.L.; Krabbenhoft, D.P.

    2003-01-01

    Snow was sampled and analyzed for total mercury (THg) on the Idaho National Engineering and Environmental Laboratory (INEEL) and surrounding region prior to the start-up of a large (9-11 g/h) gaseous mercury emission source. The objective was to determine the effects of the source on local and regional atmospheric deposition of mercury. Snow samples collected from 48 points on a polar grid near the source had THg concentrations that ranged from 4.71 to 27.26 ng/L; snow collected from regional background sites had THg concentrations that ranged from 0.89 to 16.61 ng/L. Grid samples had higher concentrations than the regional background sites, which was unexpected because the source was not operating yet. Emission of Hg from soils is a possible source of Hg in snow on the INEEL. Evidence from Hg profiles in snow and from unfiltered/filtered split samples supports this hypothesis. Ongoing work on the INEEL is investigating Hg fluxes from soils and snow.

  10. Thermal degradation products from PVC film in food-wrapping operations.

    PubMed

    Boettner, E A; Ball, G L

    1980-07-01

    Thermal degradation products of polyvinyl chloride (PVC) food-wrap films were studied under simulated supermarket conditons using a commercial wrapping machine with either a hot wire or a cool rod cutting device. A sampling hood was constructed around the wire/rod to confine and allow collection of thermal degradation products produced. Compounds analyzed and normal concentration ranges found included hydrogen chloride (1-10 micrograms per cut), plasticizer (1-50 micrograms per cut), benzene and toluene (each < 5-20 ng per cut), acrolein (25-150 ng per cut), and carbon monoxide (2-4 micrograms per cut) using the hot wire. Room air samples, collected during hot-wire cutting without the sampling hood, had < 0.25 ppm hydrogen chloride. Using the cool-rod cutting device hydrogen chloride, benzene, and toluene were not detected. Plasticizer was detected (25-86 micrograms per cut) using the cool rod.

  11. Ram-air sample collection device for a chemical warfare agent sensor

    DOEpatents

    Megerle, Clifford A.; Adkins, Douglas R.; Frye-Mason, Gregory C.

    2002-01-01

    In a surface acoustic wave sensor mounted within a body, the sensor having a surface acoustic wave array detector and a micro-fabricated sample preconcentrator exposed on a surface of the body, an apparatus for collecting air for the sensor, comprising a housing operatively arranged to mount atop the body, the housing including a multi-stage channel having an inlet and an outlet, the channel having a first stage having a first height and width proximate the inlet, a second stage having a second lower height and width proximate the micro-fabricated sample preconcentrator, a third stage having a still lower third height and width proximate the surface acoustic wave array detector, and a fourth stage having a fourth height and width proximate the outlet, where the fourth height and width are substantially the same as the first height and width.

  12. Destructive testings: dry drilling operations with TruPro system to collect samples in a powder form, from two hulls containing immobilized wastes in a hydraulic binder

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pombet, Denis; Desnoyers, Yvon; Charters, Grant

    2013-07-01

    The TruPro{sup R} process enables to collect a significant number of samples to characterize radiological materials. This innovative and alternative technique is experimented for the ANDRA quality-control inspection of cemented packages. It proves to be quicker and more prolific than the current methodology. Using classical statistics and geo-statistics approaches, the physical and radiological characteristics of two hulls containing immobilized wastes (sludges or concentrates) in a hydraulic binder are assessed in this paper. The waste homogeneity is also evaluated in comparison to ANDRA criterion. Sensibility to sample size (support effect), presence of extreme values, acceptable deviation rate and minimum number ofmore » data are discussed. The final objectives are to check the homogeneity of the two characterized radwaste packages and also to validate and reinforce this alternative characterization methodology. (authors)« less

  13. Some thoughts on problems associated with various sampling media used for environmental monitoring

    USGS Publications Warehouse

    Horowitz, A.J.

    1997-01-01

    Modern analytical instrumentation is capable of measuring a variety of trace elements at concentrations down into the single or double digit parts-per-trillion (ng l-1) range. This holds for the three most common sample media currently used in environmental monitoring programs: filtered water, whole-water and separated suspended sediment. Unfortunately, current analytical capabilities have exceeded the current capacity to collect both uncontaminated and representative environmental samples. The success of any trace element monitoring program requires that this issue be both understood and addressed. The environmental monitoring of trace elements requires the collection of calendar- and event-based dissolved and suspended sediment samples. There are unique problems associated with the collection and chemical analyses of both types of sample media. Over the past 10 years, reported ambient dissolved trace element concentrations have declined. Generally, these decreases do not reflect better water quality, but rather improvements in the procedures used to collect, process, preserve and analyze these samples without contaminating them during these steps. Further, recent studies have shown that the currently accepted operational definition of dissolved constituents (material passing a 0.45 ??m membrane filter) is inadequat owing to sampling and processing artifacts. The existence of these artifacts raises questions about the generation of accurate, precise and comparable 'dissolved' trace element data. Suspended sediment and associated trace elements can display marked short- and long-term spatial and temporal variability. This implies that spatially representative samples only can be obtained by generating composites using depth- and width-integrated sampling techniques. Additionally, temporal variations have led to the view that the determination of annual trace element fluxes may require nearly constant (e.g., high-frequency) sampling and subsequent chemical analyses. Ultimately, sampling frequency for flux estimates becomes dependent on the time period of concern (daily, weekly, monthly, yearly) and the amount of acceptable error associated with these estimates.

  14. Biosafety and containment plan & design for direct sampling of operating effluent decontamination tanks

    USDA-ARS?s Scientific Manuscript database

    Currently, Southeast Poultry Research Laboratory (SEPRL) uses an effluent decontamination system (EDS) that serves as an enhancement, or extra barrier for biocontainment. Wastewater effluent from (A)BSL-3E and (A)BSL-2E laboratories is collected in tanks for thermal inactivation (180°F for 30 minut...

  15. Children's Language Assessment--Situational Tasks.

    ERIC Educational Resources Information Center

    Conrad, Eva E.; And Others

    The Children's Language Assessment-Situational Tasks (CLA-ST) was developed to collect language samples within a normally operating classroom. The language is taken on a cassette tape recorder, which is placed at the foot of a small table. At this table, in a committee setting, four children are engaged with a teacher in an activity similar to…

  16. 77 FR 5747 - Security Zones, Seattle's Seafair Fleet Week Moving Vessels, Puget Sound, WA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-06

    ... establishment of security zones. We seek any comments or information that may lead to the discovery of a... This proposed rule would call for no new collection of information under the Paperwork Reduction Act of..., design, or operation; test methods; sampling procedures; and related management systems practices) that...

  17. Borehole Data Package for One CY 2005 CERCLA Well 699-S20-E10, 300-FF-5 Operable Unit, Hanford Site, Washington

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, Bruce A.; Bjornstad, Bruce N.; Lanigan, David C.

    2006-03-29

    This report supplies the information obtained during drilling, characterization, and installation of the new groundwater monitoring well. This document also provides a compilation of hydrogeologic and well construction information obtained during drilling, well development, and sample collection/analysis activities.

  18. Effect of bromide in a surface water intake on the formation of brominated trihalomethanes at a public water system treatment plant

    EPA Science Inventory

    This project is a collaborative drinking water research study. EPA is evaluating water samples collected by PWS operators in order to investigate relationships between bromide in source water and the formation of brominated DBPs in finished drinking water. This study will includ...

  19. 40 CFR 63.166 - Standards: Sampling connection systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... fluid to a process; or (3) Be designed and operated to capture and transport the purged process fluid to a control device that complies with the requirements of § 63.172 of this subpart; or (4) Collect... of subpart G of this part applicable to group 1 wastewater streams. If the purged process fluid does...

  20. 40 CFR 63.166 - Standards: Sampling connection systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... fluid to a process; or (3) Be designed and operated to capture and transport the purged process fluid to a control device that complies with the requirements of § 63.172 of this subpart; or (4) Collect... of subpart G of this part applicable to group 1 wastewater streams. If the purged process fluid does...

  1. Radar Image Processing for the AFIT Anechoic Chamber

    DTIC Science & Technology

    1990-12-01

    analyzer is set up for data collection using the frequency list mode option. The frequency list mode, a variation of the step sweep mode, synthesizes each of...enhanced since the frequencies are precisely repeated. The frequency list option allows the operator to select any number of data samples from 1 to 401. This

  2. 40 CFR 58.12 - Operating schedules.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... seasons exempted by the Regional Administrator. (b) For Pb manual methods, at least one 24-hour sample must be collected every 6 days except during periods or seasons exempted by the Regional Administrator... and must be approved by the Regional Administrator. (d) For manual PM2.5 samplers: (1)(i) Manual PM2.5...

  3. NASA's Student Airborne Research Program (2009-2013)

    NASA Astrophysics Data System (ADS)

    Schaller, E. L.; Shetter, R. E.

    2013-12-01

    The NASA Student Airborne Research Program (SARP) is a unique summer internship program for rising senior undergraduates majoring in any of the STEM disciplines. SARP participants acquire hands-on research experience in all aspects of an airborne research campaign, including flying onboard an major NASA resource used for studying Earth system processes. In summer 2013, thirty-two participants worked in four interdisciplinary teams to study surface, atmospheric, and oceanographic processes. Participants assisted in the operation of instruments onboard the NASA DC-8 aircraft where they sampled and measured atmospheric gases and imaged land and water surfaces in multiple spectral bands. Along with airborne data collection, students participated in taking measurements at field sites. Mission faculty and research mentors helped to guide participants through instrument operation, sample analysis, and data reduction. Over the eight-week program, each student developed an individual research project from the data collected and delivered a conference-style final presentation on his/her results. Several students will present the results of their research in science sessions at this meeting. We will discuss the results and effectiveness of the program over the past five summers and plans for the future.

  4. The Idaho National Engineering Laboratory Site environmental report for calendar Year 1990

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoff, D.L.; Mitchell, R.G.; Moore, R.

    1991-06-01

    The results of the various monitoring programs for 1990 indicate that most radioactivity from the Idaho National Engineering Laboratory (INEL) operations could not be distinguished from worldwide fallout and natural radioactivity in the region surrounding the INEL Site. Although some radioactive materials were discharged during Site operations, concentrations and doses to the surrounding population were of no health consequence and were far less than State of Idaho and Federal health protection guidelines. The first section of the report summarizes Calendar Year 1990 and January 1 through April 1, 1991, INEL activities related to compliance with environmental regulations and laws. Themore » balance of the report describes the surveillance program, the collection of foodstuffs at the INEL boundary and distant offsite locations, and the collection of air and water samples at onsite locations and offsite boundary and distant locations. The report also compares and evaluates the sample results and discusses implications, if any. Nonradioactive and radioactive effluent monitoring at the Site, and the US Geological Survey (USGS) ground-water monitoring program are also summarized. 33 refs., 18 figs., 29 tabs.« less

  5. Assessment of soil contamination by (210)Po and (210)Pb around heavy oil and natural gas fired power plants.

    PubMed

    Al-Masri, M S; Haddad, Kh; Doubal, A W; Awad, I; Al-Khatib, Y

    2014-06-01

    Soil contamination by (210)Pb and (210)Po around heavy oil and natural gas power plants has been investigated; fly and bottom ash containing enhanced levels of (210)Pb and (210)Po were found to be the main source of surface soil contamination. The results showed that (210)Pb and (210)Po in fly-ash (economizer, superheater) is highly enriched with (210)Pb and (210)Po, while bottom-ash (boiler) is depleted. The highest (210)Pb and (210)Po activity concentrations were found to be in economizer ash, whereas the lowest activity concentration was in the recirculator ash. On the other hand, (210)Pb and (210)Po activity concentrations in soil samples were found to be higher inside the plant site area than those samples collected from surrounding areas. The highest levels were found in the vicinity of Mhardeh and Tishreen power plants; both plants are operated by heavy oil and natural fuels, while the lowest values were found to be in those samples collected from Nasrieh power plant, which is only operated by one type of fuel, viz. natural gas. In addition, the levels of surface soil contamination have decreased as the distance from the power plant site center increased. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Reduction of hexavalent chromium collected on PVC filters.

    PubMed

    Shin, Y C; Paik, N W

    2000-01-01

    Chromium exists at various valences, including elemental, trivalent, and hexavalent chromium, and undergoes reduction-oxidation reactions in the environment. Since hexavalent chromium is known as a human carcinogen, it is most important to evaluate the oxidation-reduction characteristics of the hexavalent chromium species. Although hexavalent chromium can be reduced to trivalent state, the detailed information on this in workplace environments is limited. The purpose of this study was to investigate hexavalent chromium reduction in time in various conditions. A pilot chrome plating operation was prepared and operated in a laboratory for this study. There was evidence that the hexavalent chromium was reduced by time after mist generation. The percentage ratio (with 95% confidence intervals in parentheses) of hexavalent chromium to total chromium was almost 100% (99.1 approximately 102.3) immediately after mist generation, and was reduced to 87.4% (84.8 approximately 89.9) at 1 hour and 81.0% (78.3 approximately 83.5) at 2 hours, respectively. Another test indicated that hexavalent chromium collected on PVC filters was also reduced by time after sampling. Hexavalent chromium was reduced to 90.8% (88.2 approximately 93.3) at 2 hours after sampling. It also was found that hexavalent chromium was reduced during storage in air. It is recommended that air samples of hexavalent chromium be protected against reduction during storage.

  7. Evaluation of IOM personal sampler at different flow rates.

    PubMed

    Zhou, Yue; Cheng, Yung-Sung

    2010-02-01

    The Institute of Occupational Medicine (IOM) personal sampler is usually operated at a flow rate of 2.0 L/min, the rate at which it was designed and calibrated, for sampling the inhalable mass fraction of airborne particles in occupational environments. In an environment of low aerosol concentrations only small amounts of material are collected, and that may not be sufficient for analysis. Recently, a new sampling pump with a flow rate up to 15 L/min became available for personal samplers, with the potential of operating at higher flow rates. The flow rate of a Leland Legacy sampling pump, which operates at high flow rates, was evaluated and calibrated, and its maximum flow was found to be 10.6 L/min. IOM samplers were placed on a mannequin, and sampling was conducted in a large aerosol wind tunnel at wind speeds of 0.56 and 2.22 m/s. Monodisperse aerosols of oleic acid tagged with sodium fluorescein in the size range of 2 to 100 microm were used in the test. The IOM samplers were operated at flow rates of 2.0 and 10.6 L/min. Results showed that the IOM samplers mounted in the front of the mannequin had a higher sampling efficiency than those mounted at the side and back, regardless of the wind speed and flow rate. For the wind speed of 0.56 m/s, the direction-averaged (the average value of all orientations facing the wind direction) sampling efficiency of the samplers operated at 2.0 L/min was slightly higher than that of 10.6 L/min. For the wind speed of 2.22 m/s, the sampling efficiencies at both flow rates were similar for particles < 60 microm. The results also show that the IOM's sampling efficiency at these two different flow rates follows the inhalable mass curve for particles in the size range of 2 to 20 microm. The test results indicate that the IOM sampler can be used at higher flow rates.

  8. Biota dose assessment of small mammals sampled near uranium mines in northern Arizona

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jannik, T.; Minter, K.; Kuhne, W.

    In 2015, the U. S. Geological Survey (USGS) collected approximately 50 small mammal carcasses from Northern Arizona uranium mines and other background locations. Based on the highest gross alpha results, 11 small mammal samples were selected for radioisotopic analyses. None of the background samples had significant gross alpha results. The 11 small mammals were identified relative to the three ‘indicator’ mines located south of Fredonia, AZ on the Kanab Plateau (Kanab North Mine, Pinenut Mine, and Arizona 1 Mine) (Figure 1-1) and are operated by Energy Fuels Resources Inc. (EFRI). EFRI annually reports soil analysis for uranium and radium-226 usingmore » Arizona Department of Environmental Quality (ADEQ)-approved Standard Operating Procedures for Soil Sampling (EFRI 2016a, 2016b, 2017). In combination with the USGS small mammal radioiosotopic tissue analyses, a biota dose assessment was completed by Savannah River National Laboratory (SRNL) using the RESidual RADioactivity-BIOTA (RESRAD-BIOTA, V. 1.8) dose assessment tool provided by the Argonne National Laboratory (ANL 2017).« less

  9. An Interdisciplinary Method for the Visualization of Novel High-Resolution Precision Photography and Micro-XCT Data Sets of NASA's Apollo Lunar Samples and Antarctic Meteorite Samples to Create Combined Research-Grade 3D Virtual Samples for the Benefit of Astromaterials Collections Conservation, Curation, Scientific Research and Education

    NASA Technical Reports Server (NTRS)

    Blumenfeld, E. H.; Evans, C. A.; Oshel, E. R.; Liddle, D. A.; Beaulieu, K.; Zeigler, R. A.; Hanna, R. D.; Ketcham, R. A.

    2016-01-01

    New technologies make possible the advancement of documentation and visualization practices that can enhance conservation and curation protocols for NASA's Astromaterials Collections. With increasing demands for accessibility to updated comprehensive data, and with new sample return missions on the horizon, it is of primary importance to develop new standards for contemporary documentation and visualization methodologies. Our interdisciplinary team has expertise in the fields of heritage conservation practices, professional photography, photogrammetry, imaging science, application engineering, data curation, geoscience, and astromaterials curation. Our objective is to create virtual 3D reconstructions of Apollo Lunar and Antarctic Meteorite samples that are a fusion of two state-of-the-art data sets: the interior view of the sample by collecting Micro-XCT data and the exterior view of the sample by collecting high-resolution precision photography data. These new data provide researchers an information-rich visualization of both compositional and textural information prior to any physical sub-sampling. Since January 2013 we have developed a process that resulted in the successful creation of the first image-based 3D reconstruction of an Apollo Lunar Sample correlated to a 3D reconstruction of the same sample's Micro- XCT data, illustrating that this technique is both operationally possible and functionally beneficial. In May of 2016 we began a 3-year research period during which we aim to produce Virtual Astromaterials Samples for 60 high-priority Apollo Lunar and Antarctic Meteorite samples and serve them on NASA's Astromaterials Acquisition and Curation website. Our research demonstrates that research-grade Virtual Astromaterials Samples are beneficial in preserving for posterity a precise 3D reconstruction of the sample prior to sub-sampling, which greatly improves documentation practices, provides unique and novel visualization of the sample's interior and exterior features, offers scientists a preliminary research tool for targeted sub-sample requests, and additionally is a visually engaging interactive tool for bringing astromaterials science to the public.

  10. An Interdisciplinary Method for the Visualization of Novel High-Resolution Precision Photography and Micro-XCT Data Sets of NASA's Apollo Lunar Samples and Antarctic Meteorite Samples to Create Combined Research-Grade 3D Virtual Samples for the Benefit of Astromaterials Collections Conservation, Curation, Scientific Research and Education

    NASA Astrophysics Data System (ADS)

    Blumenfeld, E. H.; Evans, C. A.; Zeigler, R. A.; Righter, K.; Beaulieu, K. R.; Oshel, E. R.; Liddle, D. A.; Hanna, R.; Ketcham, R. A.; Todd, N. S.

    2016-12-01

    New technologies make possible the advancement of documentation and visualization practices that can enhance conservation and curation protocols for NASA's Astromaterials Collections. With increasing demands for accessibility to updated comprehensive data, and with new sample return missions on the horizon, it is of primary importance to develop new standards for contemporary documentation and visualization methodologies. Our interdisciplinary team has expertise in the fields of heritage conservation practices, professional photography, photogrammetry, imaging science, application engineering, data curation, geoscience, and astromaterials curation. Our objective is to create virtual 3D reconstructions of Apollo Lunar and Antarctic Meteorite samples that are a fusion of two state-of-the-art data sets: the interior view of the sample by collecting Micro-XCT data and the exterior view of the sample by collecting high-resolution precision photography data. These new data provide researchers an information-rich visualization of both compositional and textural information prior to any physical sub-sampling. Since January 2013 we have developed a process that resulted in the successful creation of the first image-based 3D reconstruction of an Apollo Lunar Sample correlated to a 3D reconstruction of the same sample's Micro-XCT data, illustrating that this technique is both operationally possible and functionally beneficial. In May of 2016 we began a 3-year research period during which we aim to produce Virtual Astromaterials Samples for 60 high-priority Apollo Lunar and Antarctic Meteorite samples and serve them on NASA's Astromaterials Acquisition and Curation website. Our research demonstrates that research-grade Virtual Astromaterials Samples are beneficial in preserving for posterity a precise 3D reconstruction of the sample prior to sub-sampling, which greatly improves documentation practices, provides unique and novel visualization of the sample's interior and exterior features, offers scientists a preliminary research tool for targeted sub-sample requests, and additionally is a visually engaging interactive tool for bringing astromaterials science to the public.

  11. PM2.5 Monitors in New England | Air Quality Planning Unit ...

    EPA Pesticide Factsheets

    2017-04-10

    The New England states are currently operating a network of 58 ambient PM2.5 air quality monitors that meet EPA's Federal Reference Method (FRM) for PM2.5, which is necessary in order for the resultant data to be used for attainment/non-attainment purposes. These monitors collect particles in the ambient air smaller than 2.5 microns in size on a filter, which is weighed prior and post sampling to produce a 24-hour sample concentration.

  12. Geosamples.org: Shared Cyberinfrastructure for Geoscience Samples

    NASA Astrophysics Data System (ADS)

    Lehnert, Kerstin; Allison, Lee; Arctur, David; Klump, Jens; Lenhardt, Christopher

    2014-05-01

    Many scientific domains, specifically in the geosciences, rely on physical samples as basic elements for study and experimentation. Samples are collected to analyze properties of natural materials and features that are key to our knowledge of Earth's dynamical systems and evolution, and to preserve a record of our environment over time. Huge volumes of samples have been acquired over decades or even centuries and stored in a large number and variety of institutions including museums, universities and colleges, state geological surveys, federal agencies, and industry. All of these collections represent highly valuable, often irreplaceable records of nature that need to be accessible so that they can be re-used in future research and for educational purposes. Many sample repositories are keen to use cyberinfrastructure capabilities to enhance access to their collections on the internet and to support and streamline collection management (accessioning of new samples, labeling, handling sample requests, etc.), but encounter substantial challenges and barriers to integrate digital sample management into their daily routine. They lack the resources (staff, funding) and infrastructure (hardware, software, IT support) to develop and operate web-enabled databases, to migrate analog sample records into digital data management systems, and to transfer paper- or spreadsheet-based workflows to electronic systems. Use of commercial software is often not an option as it incurs high costs for licenses, requires IT expertise for installation and maintenance, and often does not match the needs of the smaller repositories, being designed for large museums or different types of collections (art, archeological, biological). Geosamples.org is an alliance of sample repositories (academic, US federal and state surveys, industry) and data facilities that aims to develop a cyberinfrastructure that will dramatically advance access to physical samples for the research community, government agencies, students, educators, and the general public, while supporting, simplifying, and standardizing the work of curators in repositories, museums, and universities, and even for individual investigators who manage personal or project-based sample collections in their lab. Geosamples.org builds upon best practices and cyberinfrastructure for sample identification, registration, and documentation developed by the IGSN e.V., an international organization that governs the International Geosample Number, a persistent unique identifier for physical samples. Geosamples.org will develop a Digital Environment for Sample Curation (DESC) that will facilitate the creation, identification, and registration of 'virtual samples' and network them into an 'Internet of Samples' that will allow to discover, access, and track online physical samples, the data derived by their study, and the publications that contain these data. DESC will provide easy-to-use software tools for curators to maintain digital catalogs of their collections, to provide online access to the catalog to search for and request samples, manage sample requests and users, track collection usage and impact. Geosamples.org will also work toward joint practices for the recognition of intellectual property, build mechanisms to create sustainable business models for continuing maintenance and evolution of managing sample resources, and integrate the sample management life-cycle into professional and cultural practice of science.

  13. Hydrogeologic and water-quality data from well clusters near the wastewater-treatment plant, U.S. Marine Corps Air Station, Cherry Point, North Carolina

    USGS Publications Warehouse

    Murray, L.C.; Daniel, C. C.

    1990-01-01

    Hydrogeologic and ground-water quality data were collected near the wastewater-treatment plant and associated polishing lagoons at the Marine Corps Air Station, Cherry Point, North Carolina, in 1988. Between March and May 1988, two observation wells were installed upgradient and six wells were installed downgradient of the polishing lagoons and sampled for organic and inorganic U.S. Environmental Protection Agency priority pollutants. Placement of the well screens allowed sampling from both the upper and lower parts of the surficial aquifer. Natural gamma-ray geophysical logs were run in the four deepest wells. Lithologic logs were prepared from split-spoon samples collected during the drilling operations. Laboratory hydraulic conductivity tests were conducted on samples of fine-grained material recovered from the two confining units that separate the surficial aquifer and the drinking-water supply aquifer; values ranged from 0.011 to 0.014 foot per day (4x10-6 to 5x10-6 centimeters per second). Static water levels were recorded on April 25, 1988. Relatively low concentrations of purgeable organic compounds (up to 2.2 micrograms per liter for dichlorodifluoromethane), acid and base/neutral extractable compounds (up to 58 micrograms per liter for bis(2-ethylhexyl) phthalate), or pesticides (up to 0.03 micrograms per liter for diazinon and methyl parathion) were detected in water samples collected from all of the wells. Trace metals were detected in concentrations above minimum detectable limits in all of the wells and were found to be higher in water samples collected from the downgradient wells (up to 320 micrograms per liter for zinc) than in water samples from the upgradient wells.

  14. Effect of mining and related activities on the sediment trace element geochemistry of Lake Coeur D'Alene, Idaho, USA. Part I: Surface sediments

    USGS Publications Warehouse

    Horowitz, Arthur J.; Elrick, Kent A.; Cook, Robert B.

    1993-01-01

    During the summer of 1989 surface sediment samples were collected in Lake Coeur d'Alene, the Coeur d'Alene River and the St Joe River, Idaho, at a density of approximately one sample per square kilometre. Additional samples were collected from the banks of the South Fork of the Coeur d'Alene and the Coeur d'Alene Rivers in 1991. All the samples were collected to determine trace element concentrations, partitioning and distribution patterns, and to relate them to mining, mining related and discharge operations that have occurred in the Coeur d'Alene district since the 1880s, some of which are ongoing.Most of the surface sediments in Lake Coeur d'Alene north of Conkling Point and Carey Bay are substantially enriched in Ag, As, Cu, Cd, Hg, Pb, Sb and Zn relative to unaffected sediments in the southern portion of the lake near the St Joe River. All the trace element enriched sediments are extremely fine grained (mean grain sizes « 63 μm). Most of the enriched trace elements, based on both the chemical analyses of separated heavy and light mineral fractions and a two step sequential extraction procedure, are associated with an operationally defined Fe oxide phase; much smaller percentages are associated either with operationally defined organics/sulphides or refractory phases.The presence, concentration and distribution of the Fe oxides and heavy minerals indicates that a substantial portion of the enriched trace elements are probably coming from the Coeur d'Alene River, which is serving as a point source. Within the lake, this relatively simple point source pattern is complicated by a combination of (1) the formation of trace element rich authigenic Fe oxides that appear to have reprecipitated from material solubilized from anoxic bed sediments and (2) physical remobilization by currents and wind driven waves. The processes that have caused the trace element enrichment in the surface sediments of Lake Coeur d'Alene are likely to continue for the foreseeable future.

  15. Diagnosis of acute puerperal metritis by electronic nose device analysis of vaginal discharge in dairy cows.

    PubMed

    Burfeind, O; Bruins, M; Bos, A; Sannmann, I; Voigtsberger, R; Heuwieser, W

    2014-07-01

    The objective of this study was to estimate the diagnostic accuracy of an electronic nose device using vaginal discharge samples to diagnose acute puerperal metritis (APM) in dairy cows. Uterine fluid was sampled manually with a gloved hand and under sterile conditions for electronic nose device analysis (day in milk (DIM) 2, 5, and 10) and bacteriologic examination (DIM 5), respectively, and on additional days, if APM was diagnosed during the daily clinical examinations. A dataset containing samples from 70 cows was used to create a model and to validate the APM status predicted by this model, respectively. Half of the dataset (n = 35; 14 healthy and 21 metritic cows) was provided with information regarding the APM diagnosis and contained all three measurements (DIM 2, 5, and 10) for each cow and was used as a training set whereas the second half was blinded (n = 35; 14 healthy and 21 metritic cows) and contained only the samples collected on DIM 5 of each cow and was used to validate the created prediction model. A receiver operating characteristic curve was calculated using the prediction results of the validation test. The best observed sensitivity was 100% with specificity of 91.6% when using a threshold value of 0.3. The calculated P-value for the receiver operating characteristic curve was less than 0.01. Overall, Escherichia coli was isolated in eight of 28 (28.6%) and 22 of 42 (52.4%) samples collected from healthy and metritic cows, respectively. Trueperella pyogenes and Fusobacterium necrophorum were isolated in 14 and six of 28 (50.0% and 21.4%) and 17 and 16 of 42 (40.5% and 38.1%) samples collected from healthy and metritic cows, respectively. The prevalence of Escherichia coli and Trueperella pyogenes was similar in the samples obtained from metritic cows used for the training set and the validation test. The results are promising especially because of the objective nature of the measurements obtained by the electronic nose device. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Determination and comparison of microbial loads in atmospheres of two hospitals in Izmir, Turkey.

    PubMed

    Aydin Çakir, Nergüze; Uçar, Füsun Bahriye; Haliki Uztan, Alev; Corbaci, Cengiz; Akpinar, Onur

    2013-01-01

    Nosocomial infections, also known as hospital-acquired infections, has become one of the most important health problems in health care units worldwide. The presented study aims to determine the average amount of microorganism loads and to show that the atmospheres of the two hospitals can be a potential source regarding nosocomial infections. The effect of surface and floor disinfection processes in the two hospitals and the antibiotic susceptibility of the bacterial isolates were also evaluated. Microorganisms were isolated from air samples collected from different areas (patient wards, corridors, operating theatres and postoperative units) of the two hospitals in Izmir. Sampling was conducted between December 2006 - March 2007. During the 3-month sampling period, the average number of live microorganisms in the air samples collected from second-class environments in the hospital 1 and the hospital 2 was found to be 224.44 and 536.66 cfu/m(3) , respectively. The average number of microorganisms in hospital 2 collected before the disinfection process was higher than those after the disinfection process. However, because of the closure of the air-conditioning system and the hepa filters after the disinfection process, this was reversed in hospital 1. In total, 54 and 42 isolates were obtained from hospital 1 and hospital 2, respectively. 49 isolates from hospital 1 and 35 isolates from hospital 2 were identified as Staphylacoccus sp. The remaining isolates were identified as Aerococcus sp. and Enterococcus sp. Pseudomonas sp. was not determined in the air samples of the two hospitals. It was detected that the microbial loads in the atmospheres of the two hospitals studied varied greatly depending on the number of people in the environment. As the results indicate, the total number of microorganisms in the atmospheres of operating theatres in both hospitals does not pose a threat according to the Air Microbe Index.

  17. Early Results and Spaceflight Implications of the SWAB Flight Experiment

    NASA Technical Reports Server (NTRS)

    Ott, C. Mark; Pierson, Duane L.

    2007-01-01

    Microbial monitoring of spacecraft environments provides key information in the assessment of infectious disease risk to the crew. Monitoring aboard the Mir space station and International Space Station (ISS) has provided a tremendous informational baseline to aid in determining the types and concentrations of microorganisms during a mission. Still, current microbial monitoring hardware utilizes culture-based methodology which may not detect many medically significant organisms, such as Legionella pneumophila. We hypothesize that evaluation of the ISS environment using non-culture-based technologies would reveal microorganisms not previously reported in spacecraft, allowing for a more complete health assessment. To achieve this goal, a spaceflight experiment, operationally designated as SWAB, was designed to evaluate the DNA from environmental samples collected from ISS and vehicles destined for ISS. Results from initial samples indicate that the sample collection and return procedures were successful. Analysis of these samples using denaturing gradient gel electrophoresis and targeted PCR primers for fungal contaminants is underway. The current results of SWAB and their implication for in-flight molecular analysis of environmental samples will be discussed.

  18. A Robot Equipped with a High-Speed LSPR Gas Sensor Module for Collecting Spatial Odor Information from On-Ground Invisible Odor Sources.

    PubMed

    Yang, Zhongyuan; Sassa, Fumihiro; Hayashi, Kenshi

    2018-06-22

    Improving the efficiency of detecting the spatial distribution of gas information with a mobile robot is a great challenge that requires rapid sample collection, which is basically determined by the speed of operation of gas sensors. The present work developed a robot equipped with a high-speed gas sensor module based on localized surface plasmon resonance. The sensor module is designed to sample gases from an on-ground odor source, such as a footprint material or artificial odor marker, via a fine sampling tubing. The tip of the sampling tubing was placed close to the ground to reduce the sampling time and the effect of natural gas diffusion. On-ground ethanol odor sources were detected by the robot at high resolution (i.e., 2.5 cm when the robot moved at 10 cm/s), and the reading of gas information was demonstrated experimentally. This work may help in the development of environmental sensing robots, such as the development of odor source mapping and multirobot systems with pheromone tracing.

  19. Occurrence of heterotrophic bacteria and fungi in an aviation fuel handling system and its relationship with fuel fouling.

    PubMed

    Ferrari, M D; Neirotti, E; Albornoz, C

    1998-01-01

    Clean, dry and contaminant-free fuel is necessary for safe and economical aircraft operation. Microbial growth in aviation fuel handling systems can alter the quality of the product. This paper reports the occurrence of heterotrophic bacteria and fungi in a handling system of jet A-1 aviation turbine fuel. A total of 350 samples were collected during 1990-1996. The aerobic microorganisms in fuel samples were mainly fungi, 85% of samples containing < or = 100 cfu/l (range 0 (< 1 cfu/l) to 2000 cfu/l). The predominant fungi were Cladosporium and Aspergillus. Water was observed mainly in samples extracted from the drainage pipes of two tanks used frequently as intermediate storage tanks. The aerobic heterotrophic microorganisms found in water samples were mostly bacteria, counts varying from 100 to 8.8 x 10(7) cfu/ml, with 85% of samples containing 10(4)-10(7) cfu/ml. There was a preponderance of Pseudomonas spp. Bacterial contaminants belonging to the genus Flavobacterium and Aeromonas were also identified. Sulphate reducing bacteria were detected in 80% of water samples. It was not possible to assign a maximum microbial contamination level above which maintenance is required and it is suggested that analysis of successive samples from the same site are necessary for this purpose. Microbial sludges produced in the laboratory and collected from a contaminated tank bottom were analysed chemically. The data are presented and discussed. Samples collected from the supply pipes of tanks and refueller trucks during the period surveyed always met the standard specifications.

  20. After site selection and before data analysis: sampling, sorting, and laboratory procedures used in stream benthic macroinvertebrate monitoring programs by USA state agencies

    USGS Publications Warehouse

    Carter, James L.; Resh, Vincent H.

    2001-01-01

    A survey of methods used by US state agencies for collecting and processing benthic macroinvertebrate samples from streams was conducted by questionnaire; 90 responses were received and used to describe trends in methods. The responses represented an estimated 13,000-15,000 samples collected and processed per year. Kicknet devices were used in 64.5% of the methods; other sampling devices included fixed-area samplers (Surber and Hess), artificial substrates (Hester-Dendy and rock baskets), grabs, and dipnets. Regional differences existed, e.g., the 1-m kicknet was used more often in the eastern US than in the western US. Mesh sizes varied among programs but 80.2% of the methods used a mesh size between 500 and 600 (mu or u)m. Mesh size variations within US Environmental Protection Agency regions were large, with size differences ranging from 100 to 700 (mu or u)m. Most samples collected were composites; the mean area sampled was 1.7 m2. Samples rarely were collected using a random method (4.7%); most samples (70.6%) were collected using "expert opinion", which may make data obtained operator-specific. Only 26.3% of the methods sorted all the organisms from a sample; the remainder subsampled in the laboratory. The most common method of subsampling was to remove 100 organisms (range = 100-550). The magnification used for sorting ranged from 1 (sorting by eye) to 30x, which results in inconsistent separation of macroinvertebrates from detritus. In addition to subsampling, 53% of the methods sorted large/rare organisms from a sample. The taxonomic level used for identifying organisms varied among taxa; Ephemeroptera, Plecoptera, and Trichoptera were generally identified to a finer taxonomic resolution (genus and species) than other taxa. Because there currently exists a large range of field and laboratory methods used by state programs, calibration among all programs to increase data comparability would be exceptionally challenging. However, because many techniques are shared among methods, limited testing could be designed to evaluate whether procedural differences affect the ability to determine levels of environmental impairment using benthic macroinvertebrate communities.

  1. Recovery of phosphonate surface contaminants from glass using a simple vacuum extractor with a solid-phase microextraction fiber.

    PubMed

    Groenewold, Gary S; Scott, Jill R; Rae, Catherine

    2011-07-04

    Recovery of chemical contaminants from fixed surfaces for analysis can be challenging, particularly if it is not possible to acquire a solid sample to be taken to the laboratory. A simple device is described that collects semi-volatile organic compounds from fixed surfaces by creating an enclosed volume over the surface, then generating a modest vacuum. A solid-phase microextraction (SPME) fiber is then inserted into the evacuated volume where it functions to sorb volatilized organic contaminants. The device is based on a syringe modified with a seal that is used to create the vacuum, with a perforable plunger through which the SPME fiber is inserted. The reduced pressure speeds partitioning of the semi-volatile compounds into the gas phase and reduces the boundary layer around the SPME fiber, which enables a fraction of the volatilized organics to partition into the SPME fiber. After sample collection, the SPME fiber is analyzed using conventional gas chromatography/mass spectrometry. The methodology has been used to collect organophosphorus compounds from glass surfaces, to provide a simple test for the functionality of the devices. Thirty minute sampling times (ΔT(vac)) resulted in fractional recovery efficiencies that ranged from 10(-3) to >10(-2), and in absolute terms, collection of low nanograms was demonstrated. Fractional recovery values were positively correlated to the vapor pressure of the compounds being sampled. Fractional recovery also increased with increasing ΔT(vac) and displayed a roughly logarithmic profile, indicating that an operational equilibrium is being approached. Fractional recovery decreased with increasing time between exposure and sampling; however, recordable quantities of the phosphonates could be collected three weeks after exposure. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Swab or biopsy samples for bioburden testing of allograft musculoskeletal tissue?

    PubMed

    Varettas, Kerry

    2014-12-01

    Swab and biopsy samples of allograft musculoskeletal tissue are most commonly collected by tissue banks for bacterial and fungal bioburden testing. An in vitro study was performed using the National Committee for Clinical Laboratory Standards standard 'Quality control of microbiological transport systems' (2003) to validate and evaluate the recovery of six challenge organisms from swab and biopsy samples of allograft musculoskeletal tissue. On average, 8.4 to >100 and 7.2 to >100 % of the inoculum was recovered from swab and biopsy samples respectively. A retrospective review of donor episodes was also performed, consisting of paired swab and biopsy samples received in this laboratory during the period 2001-2012. Samples of allograft femoral heads were collected from living donors during hip operations. From the 3,859 donor episodes received, 21 paired swab and biopsy samples each recovered an isolate, 247 swab samples only and 79 biopsy samples only were culture positive. Low numbers of challenge organisms were recovered from inoculated swab and biopsy samples in the in vitro study and validated their use for bioburden testing of allograft musculoskeletal tissue. Skin commensals were the most common group of organisms isolated during a 12-year retrospective review of paired swab and biopsy samples from living donor allograft femoral heads. Paired swab and biopsy samples are a suitable representative sample of allograft musculoskeletal tissue for bioburden testing.

  3. Validation of standard operating procedures in a multicenter retrospective study to identify -omics biomarkers for chronic low back pain.

    PubMed

    Dagostino, Concetta; De Gregori, Manuela; Gieger, Christian; Manz, Judith; Gudelj, Ivan; Lauc, Gordan; Divizia, Laura; Wang, Wei; Sim, Moira; Pemberton, Iain K; MacDougall, Jane; Williams, Frances; Van Zundert, Jan; Primorac, Dragan; Aulchenko, Yurii; Kapural, Leonardo; Allegri, Massimo

    2017-01-01

    Chronic low back pain (CLBP) is one of the most common medical conditions, ranking as the greatest contributor to global disability and accounting for huge societal costs based on the Global Burden of Disease 2010 study. Large genetic and -omics studies provide a promising avenue for the screening, development and validation of biomarkers useful for personalized diagnosis and treatment (precision medicine). Multicentre studies are needed for such an effort, and a standardized and homogeneous approach is vital for recruitment of large numbers of participants among different centres (clinical and laboratories) to obtain robust and reproducible results. To date, no validated standard operating procedures (SOPs) for genetic/-omics studies in chronic pain have been developed. In this study, we validated an SOP model that will be used in the multicentre (5 centres) retrospective "PainOmics" study, funded by the European Community in the 7th Framework Programme, which aims to develop new biomarkers for CLBP through three different -omics approaches: genomics, glycomics and activomics. The SOPs describe the specific procedures for (1) blood collection, (2) sample processing and storage, (3) shipping details and (4) cross-check testing and validation before assays that all the centres involved in the study have to follow. Multivariate analysis revealed the absolute specificity and homogeneity of the samples collected by the five centres for all genetics, glycomics and activomics analyses. The SOPs used in our multicenter study have been validated. Hence, they could represent an innovative tool for the correct management and collection of reliable samples in other large-omics-based multicenter studies.

  4. Strategy for Passivating Char Efficiently at the Pilot Scale

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dunning, Timothy C

    Fast pyrolysis is a promising pathway for the commercialization of liquid transportation fuels from biomass. Fast pyrolysis is performed at moderate heat (450-600 degrees Celcius) in an oxygen-deficient environment. One of the products of fast pyrolysis is biochar, which is often used as a heat source or as a soil amendment. Biochar is a partially reacted solid that is created in the production of bio-oil during fast pyrolysis. Biochar produced at these conditions contains significant quantities of carbon that adsorb oxygen when exposed to air. Biochar adsorption of oxygen is an exothermic process that may generate sufficient heat for combustionmore » in ambient air. Biochar is also a self-insulating material which compounds the effects of heat generated internally. These factors lead to safety concerns and material handling difficulties. The Thermochemical Process Development Unit at the National Renewable Energy Laboratory operates a pilot plant that may be configured for fast pyrolysis, gasification, and will be introducing catalytic fast pyrolysis capabilities in 2018. The TCPDU designed and installed a system to introduce oxygen to collected biochar systematically for a controlled passivation. Biochar is collected and cooled in an oxygen deficient environment during fast pyrolysis. Oxygen is then introduced to the biochar on a mass flow basis. A sparger imbedded within the biochar sample near the bottom of the bed flows air diluted with nitrogen into the char bed, and excess gasses are removed from the top of the collection drum, above the char bed. Pressure within the collection drum is measured indicating adequate flow through filters. Sample weight is recorded before and after passivation. During passivation, temperature is measured at 18 points within the char bed. Oxygen content and temperature are measured leaving the char bed. Maximum temperature parameters were established to ensure operator safety during biochar passivation. Extensive passivation data was collected on pine and blended feedstocks and has been analyzed to characterize the exotherm of char samples. Observations and data collected while passivating char will be discussed.« less

  5. An analysis of workplace exposures to benzene over four decades at a petrochemical processing and manufacturing facility (1962-1999).

    PubMed

    Sahmel, J; Devlin, K; Burns, A; Ferracini, T; Ground, M; Paustenbach, D

    2013-01-01

    Benzene, a known carcinogen, can be generated as a by-product during the use of petroleum-based raw materials in chemical manufacturing. The aim of this study was to analyze a large data set of benzene air concentration measurements collected over nearly 40 years during routine employee exposure monitoring at a petrochemical manufacturing facility. The facility used ethane, propane, and natural gas as raw materials in the production of common commercial materials such as polyethylene, polypropylene, waxes, adhesives, alcohols, and aldehydes. In total, 3607 benzene air samples were collected at the facility from 1962 to 1999. Of these, in total 2359 long-term (>1 h) personal exposure samples for benzene were collected during routine operations at the facility between 1974 and 1999. These samples were analyzed by division, department, and job title to establish employee benzene exposures in different areas of the facility over time. Sampling data were also analyzed by key events over time, including changes in the occupational exposure limits (OELs) for benzene and key equipment process changes at the facility. Although mean benzene concentrations varied according to operation, in nearly all cases measured benzene quantities were below the OEL in place at the time for benzene (10 ppm for 1974-1986 and 1 ppm for 1987-1999). Decreases in mean benzene air concentrations were also found when data were evaluated according to 7- to 10-yr periods following key equipment process changes. Further, an evaluation of mortality rates for a retrospective employee cohort (n = 3938) demonstrated that the average personal benzene exposures at this facility (0.89 ppm for the period 1974-1986 and 0.125 ppm for the period 1987-1999) did not result in increased standardized mortality ratio (SMRs) for diseases or malignancies of the lymphatic system. The robust nature of this data set provides comprehensive exposure information that may be useful for assessing human benzene exposures at similar facilities. The data also provide a basis for comparable measured exposure levels and the potential for adverse health effects. These data may also prove beneficial for comparing relative exposure potential for production versus nonproduction operations and the relationship between area and personal breathing zone samples.

  6. A water-resources data-network evaluation for Monterey County, California; Phase 3, Northern Salinas River drainage basin

    USGS Publications Warehouse

    Templin, W.E.; Schluter, R.C.

    1990-01-01

    This report evaluates existing data collection networks and possible additional data collection to monitor quantity and quality of precipitation, surface water, and groundwater in the northern Salinas River drainage basin, California. Of the 34 precipitation stations identified, 20 were active and are concentrated in the northwestern part of the study area. No precipitation quality networks were identified, but possible data collection efforts include monitoring for acid rain and pesticides. Six of ten stream-gaging stations are active. Two surface water quality sites are sampled for suspended sediment, specific conductance, and chloride; one U.S. Geological Survey NASOAN site and one site operated by California Department of Water Resources make up the four active sampling locations; reactivation of 45 inactive surface water quality sites might help to achieve objectives described in the report. Three local networks measure water levels in 318 wells monthly, during peak irrigation, and at the end of the irrigation season. Water quality conditions are monitored in 379 wells; samples are collected in summer to monitor saltwater intrusion near Castroville and are also collected annually throughout the study area for analysis of chloride, specific conductance, and nitrate. An ideal baseline network would be an evenly spaced grid of index wells with a density of one per section. When baseline conditions are established, representative wells within the network could be monitored periodically according to specific data needs. (USGS)

  7. Pediatric appendicitis in a developing country: what are the clinical predictors and outcome of perforation?

    PubMed

    Ngim, Chin Fang; Quek, Kia Fatt; Dhanoa, Amreeta; Khoo, Joon Joon; Vellusamy, Muthualhagi; Ng, Chen Siew

    2014-12-01

    This study explored the risk factors and outcomes associated with perforation in children who underwent emergency appendicectomies. A retrospective cross-sectional study was conducted on children <13 years old who underwent appendicectomies in a Malaysian hospital in 2007. One hundred thirty-four children underwent appendicectomies of which 118 were confirmed histologically. Sixty-one (52%) were perforated. Children with perforation had significantly longer duration of symptoms (p < 0.001), higher white cell count and absolute neutrophil counts (p = 0.013), with longer intra-operative period (p < 0.001) and post-operative recovery period (p < 0.001). Of the 52 samples of pus collected intra-operatively, 37 (71.1%) yielded positive cultures that were predominantly Escherichia coli (n = 27). Both the patients who had Staphylococcus aureus cultured from pus collected intra-operatively had significant pyogenic complications (scrotal pyocele and intra-abdominal abscess). Children whose appendicitis were perforated had longer duration of symptoms, higher white cell counts and absolute neutrophil counts. Those with S.aureus cultured from intra-operative pus appeared to suffer more complications. © The Author [2014]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Significance of biological resource collection and tumor tissue bank creation.

    PubMed

    Yu, Ying-Yan; Zhu, Zheng-Gang

    2010-01-15

    Progress in the molecular oncology of gastrointestinal carcinomas depends on high quality cancer tissues for research. Recent acceleration on new technological platforms as well as the "omics" revolution increases the demands on tissues and peripheral blood for research at the DNA, mRNA and protein levels. Tissue bank creation emerges as a priority. Tumor tissue banks are facilities that are organized to collect, store and distribute samples of tumor and normal tissue for further use in basic and translational cancer research. The samples are generally obtained immediately after excision, prior to fixation, to ensure optimal preservation of proteins and nucleic acids. It is possible for surgeons or pathologists to collect fresh tissue prospectively during their routine dissection procedures. Most tissue banks are "project-driven" tumor banks, which are specialized collections of tumor samples on which their research is based. Systematic collection of all available tumor tissue is much rarer. High quality tissue banks need the collaboration of clinicians and basic scientists, but also the informed consent of patients and ethical approval. Through the standard operation procedure, snap frozen fresh tissue collection, storage and quality control for cryopreserved tissues are the pivotal factors on tissue bank construction and maintaining. The purpose of the tissue bank creation is enhancing the quality and speed on both the basic and translational research on gastrointestinal cancer. The quality assurance and quality control are handled based on reviewing HE staining slides or touch imprint cytology by pathologists.

  9. A Survey on Aflatoxin M1 Content in Sheep and Goat Milk Produced in Sardinia Region, Italy (2005-2013).

    PubMed

    Virdis, Salvatore; Scarano, Christian; Spanu, Vincenzo; Murittu, Gavino; Spanu, Carlo; Ibba, Ignazio; De Santis, Enrico Pietro Luigi

    2014-12-09

    In the present work the results of a survey conducted in Sardinia Region on Aflatoxin M 1 (AFM 1 ) contamination in milk of small ruminants from 2005 to 2013 are reported. A total of 517 sheep and 88 goat milk samples from bulk tank, tank trucks and silo tank milk were collected. Analyses were performed by the Regional Farmers Association laboratory using high-performance liquid chromatography following the ISO 14501:1998 standard. None of the sheep milk samples analysed during 2005-2012 showed AFM 1 contamination. In sheep milk samples collected in 2013, 8 out of 172 (4.6%) were contaminated by AFM 1 with a concentration (mean±SD) of 12.59±14.05 ng/L. In one bulk tank milk sample 58.82 ng/L AFM 1 was detected, exceeding the EU limit. In none of goat milk samples analysed from 2010 to 2012 AFM 1 was detected. In 2013, 9 out of 66 goat milk samples (13.6%) showed an AFM 1 concentration of 47.21±19.58 ng/L. Two of these samples exceeded the EU limit, with concentrations of 62.09 and 138.6 ng/L. Higher contamination frequency and concentration rates were detected in bulk tank milk samples collected at farm than in bulk milk truck or silo samples, showing a dilution effect on AFM 1 milk content along small ruminants supply chain. The rate and levels of AFM 1 contamination in sheep and goat milk samples were lower than other countries. However, the small number of milk samples analysed for AFM 1 in Sardinia Region in 2005-2013 give evidence that food business operators check programmes should be improved to ensure an adequate monitoring of AFM 1 contamination in small ruminant dairy chain.

  10. Prolonged Outbreak of Mycobacterium chimaera Infection After Open-Chest Heart Surgery.

    PubMed

    Sax, Hugo; Bloemberg, Guido; Hasse, Barbara; Sommerstein, Rami; Kohler, Philipp; Achermann, Yvonne; Rössle, Matthias; Falk, Volkmar; Kuster, Stefan P; Böttger, Erik C; Weber, Rainer

    2015-07-01

    Invasive Mycobacterium chimaera infections were diagnosed in 2012 in 2 heart surgery patients on extracorporeal circulation. We launched an outbreak investigation to identify the source and extent of the potential outbreak and to implement preventive measures. We collected water samples from operating theaters, intensive care units, and wards, including air samples from operating theaters. Mycobacterium chimaera strains were characterized by randomly amplified polymorphic DNA polymerase chain reaction (RAPD-PCR). Case detection was performed based on archived histopathology samples and M. chimaera isolates since 2006, and the patient population at risk was prospectively surveyed. We identified 6 male patients aged between 49 and 64 years with prosthetic valve endocarditis or vascular graft infection due to M. chimaera, which became clinically manifest with a latency of between 1.5 and 3.6 years after surgery. Mycobacterium chimaera was isolated from cardiac tissue specimens, blood cultures, or other biopsy specimens. We were able also to culture M. chimaera from water circuits of heater-cooler units connected to the cardiopulmonary bypass, and air samples collected when the units were in use. RAPD-PCR demonstrated identical patterns among M. chimaera strains from heater-cooler unit water circuits and air samples, and strains in 2 patient clusters. The epidemiological and microbiological features of this prolonged outbreak provided evidence for the airborne transmission of M. chimaera from contaminated heater-cooler unit water tanks to patients during open-heart surgery. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  11. McNary Dam, Ice Harbor Dam, and Lower Monumental Dam Smolt Monitoring Program; 1996 Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hillson, Todd; Lind, Sharon; Price, William

    1997-07-01

    The Washington Department of Fish & Wildlife (WDFW) assumed responsibility for the Smolt Monitoring Program at McNary Dam on the Columbia River in 1990 and at the new juvenile collection facility at Lower Monumental Dam on the Snake River in 1993. In 1996, Smolt Monitoring Program activities also began at the new juvenile collection facility located at Ice Harbor Dam. This report summarizes the 1996 Smolt Monitoring work at all three sites. The work at Ice Harbor consisted of Gas Bubble Trauma (GBT) monitoring only. In general, the 1996 passage season at both the McNary and Lower Monumental sites canmore » be characterized by reduced passage of juveniles through the collection systems due to elevated river flows and spill, and low (<1%) overall facility mortality rates most likely resulting from cooler water temperatures. In accordance with the National Marine Fisheries Service recommendations (NMFS, 1995) all spring migrants were bypassed at McNary Dam in 1996. Mechanical problems within the McNary collection system resulted in collection and sampling activities being delayed until April 18 at this site, while sampling and collection began on the scheduled starting date of April 1 at Lower Monumental Dam. Monitoring operations were conducted through December 14 at McNary Dam and through October 28 at Lower Monumental Dam. An ongoing transportation evaluation summer migrant marking program was conducted at McNary Dam in 1996 by the NMFS. This necessitated the sampling of 394,211 additional fish beyond the recommended sampling guidelines. All total, 509,237 and 31,219 juvenile salmonids were anesthetized and individually counted, examined for scale loss, injuries, and brands by WDFW Smolt Monitoring personnel in 1996 at McNary Dam and Lower Monumental Dam, respectively.« less

  12. Fine Increment Soil Collector (FISC): A new device to support high resolution soil and sediment sampling for agri-environmental assessments

    NASA Astrophysics Data System (ADS)

    Mabit, Lionel; Meusburger, Katrin; Iurian, Andra-Rada; Owens, Philip N.; Toloza, Arsenio; Alewell, Christine

    2014-05-01

    Soil and sediment related research for terrestrial agri-environmental assessments requires accurate depth incremental sampling of soil and exposed sediment profiles. Existing coring equipment does not allow collecting soil/sediment increments at millimetre resolution. Therefore, the authors have designed an economic, portable, hand-operated surface soil/sediment sampler - the Fine Increment Soil Collector (FISC) - which allows extensive control of soil/sediment sampling process and easy recovery of the material collected by using a simple screw-thread extraction system. In comparison with existing sampling tools, the FISC has the following advantages and benefits: (i) it permits sampling of soil/sediment samples at the top of the profile; (ii) it is easy to adjust so as to collect soil/sediment at mm resolution; (iii) it is simple to operate by one single person; (iv) incremental samples can be performed in the field or at the laboratory; (v) it permits precise evaluation of bulk density at millimetre vertical resolution; and (vi) sample size can be tailored to analytical requirements. To illustrate the usefulness of the FISC in sampling soil and sediments for 7Be - a well-known cosmogenic soil tracer and fingerprinting tool - measurements, the sampler was tested in a forested soil located 45 km southeast of Vienna in Austria. The fine resolution increments of 7Be (i.e. 2.5 mm) affects directly the measurement of the 7Be total inventory but above all impacts the shape of the 7Be exponential profile which is needed to assess soil movement rates. The FISC can improve the determination of the depth distributions of other Fallout Radionuclides (FRN) - such as 137Cs, 210Pbexand239+240Pu - which are frequently used for soil erosion and sediment transport studies and/or sediment fingerprinting. Such a device also offers great potential to investigate FRN depth distributions associated with fallout events such as that associated with nuclear emergencies. Furthermore, prior to remediation activities - such as topsoil removal - in contaminated soils and sediments (e.g. by heavy metals, pesticides or nuclear power plant accident releases), basic environmental assessment often requires the determination of the extent and the depth penetration of the different contaminants, precision that can be provided by using the FISC.

  13. A microfluidic platform for precision small-volume sample processing and its use to size separate biological particles with an acoustic microdevice [Precision size separation of biological particles in small-volume samples by an acoustic microfluidic system

    DOE PAGES

    Fong, Erika J.; Huang, Chao; Hamilton, Julie; ...

    2015-11-23

    Here, a major advantage of microfluidic devices is the ability to manipulate small sample volumes, thus reducing reagent waste and preserving precious sample. However, to achieve robust sample manipulation it is necessary to address device integration with the macroscale environment. To realize repeatable, sensitive particle separation with microfluidic devices, this protocol presents a complete automated and integrated microfluidic platform that enables precise processing of 0.15–1.5 ml samples using microfluidic devices. Important aspects of this system include modular device layout and robust fixtures resulting in reliable and flexible world to chip connections, and fully-automated fluid handling which accomplishes closed-loop sample collection,more » system cleaning and priming steps to ensure repeatable operation. Different microfluidic devices can be used interchangeably with this architecture. Here we incorporate an acoustofluidic device, detail its characterization, performance optimization, and demonstrate its use for size-separation of biological samples. By using real-time feedback during separation experiments, sample collection is optimized to conserve and concentrate sample. Although requiring the integration of multiple pieces of equipment, advantages of this architecture include the ability to process unknown samples with no additional system optimization, ease of device replacement, and precise, robust sample processing.« less

  14. Fluid sampling tool

    DOEpatents

    Garcia, Anthony R.; Johnston, Roger G.; Martinez, Ronald K.

    1999-05-25

    A fluid sampling tool for sampling fluid from a container. The tool has a fluid collecting portion which is drilled into the container wall, thereby affixing it to the wall. The tool may have a fluid extracting section which withdraws fluid collected by the fluid collecting section. The fluid collecting section has a fluted shank with an end configured to drill a hole into a container wall. The shank has a threaded portion for tapping the borehole. The shank is threadably engaged to a cylindrical housing having an inner axial passageway sealed at one end by a septum. A flexible member having a cylindrical portion and a bulbous portion is provided. The housing can be slid into an inner axial passageway in the cylindrical portion and sealed to the flexible member. The bulbous portion has an outer lip defining an opening. The housing is clamped into the chuck of a drill, the lip of the bulbous section is pressed against a container wall until the shank touches the wall, and the user operates the drill. Wall shavings (kerf) are confined in a chamber formed in the bulbous section as it folds when the shank advances inside the container. After sufficient advancement of the shank, an o-ring makes a seal with the container wall.

  15. Fluid sampling tool

    DOEpatents

    Garcia, A.R.; Johnston, R.G.; Martinez, R.K.

    1999-05-25

    A fluid sampling tool is described for sampling fluid from a container. The tool has a fluid collecting portion which is drilled into the container wall, thereby affixing it to the wall. The tool may have a fluid extracting section which withdraws fluid collected by the fluid collecting section. The fluid collecting section has a fluted shank with an end configured to drill a hole into a container wall. The shank has a threaded portion for tapping the borehole. The shank is threadably engaged to a cylindrical housing having an inner axial passageway sealed at one end by a septum. A flexible member having a cylindrical portion and a bulbous portion is provided. The housing can be slid into an inner axial passageway in the cylindrical portion and sealed to the flexible member. The bulbous portion has an outer lip defining an opening. The housing is clamped into the chuck of a drill, the lip of the bulbous section is pressed against a container wall until the shank touches the wall, and the user operates the drill. Wall shavings (kerf) are confined in a chamber formed in the bulbous section as it folds when the shank advances inside the container. After sufficient advancement of the shank, an o-ring makes a seal with the container wall. 6 figs.

  16. Characterizing shipboard bilgewater effluent before and after treatment.

    PubMed

    McLaughlin, Christine; Falatko, Debra; Danesi, Robin; Albert, Ryan

    2014-04-01

    Operational discharges from oceangoing vessels, including discharges of bilgewater, release oil into marine ecosystems that can potentially damage marine life, terrestrial life, human health, and the environment. Bilgewater is a mix of oily fluids and other pollutants from a variety of sources onboard a vessel. If bilgewater cannot be retained onboard, it must be treated by an oily water separator before discharge for larger ocean-going vessels. We evaluated the effectiveness of bilgewater treatment systems by analyzing land-based type approval data, collecting and analyzing shipboard bilgewater effluent data, assessing bilgewater effluent concentrations compared to regulatory standards, evaluating the accuracy of shipboard oil content monitors relative to analytical results, and assessing additional pollution reduction benefits of treatment systems. Land-based type approval data were gathered for 20 treatment systems. Additionally, multiple samples of influent and effluent from operational bilgewater treatment systems onboard three vessels were collected and analyzed, and compared to the land-based type approval data. Based on type approval data, 15 treatment systems were performing below 5 ppm oil. Shipboard performance measurements verified land-based type approval data for the three systems that were sampled. However, oil content monitor readings were more variable than actual oil concentration measurements from effluent samples, resulting in false negatives and positives. The treatment systems sampled onboard for this study generally reduced the majority of other potentially harmful pollutants, which are not currently regulated, with the exception of some heavy metal analytes.

  17. Underway Sampling of Marine Inherent Optical Properties on the Tara Oceans Expedition as a Novel Resource for Ocean Color Satellite Data Product Validation

    NASA Technical Reports Server (NTRS)

    Werdell, P. Jeremy; Proctor, Christopher W.; Boss, Emmanuel; Leeuw, Thomas; Ouhssain, Mustapha

    2013-01-01

    Developing and validating data records from operational ocean color satellite instruments requires substantial volumes of high quality in situ data. In the absence of broad, institutionally supported field programs, organizations such as the NASA Ocean Biology Processing Group seek opportunistic datasets for use in their operational satellite calibration and validation activities. The publicly available, global biogeochemical dataset collected as part of the two and a half year Tara Oceans expedition provides one such opportunity. We showed how the inline measurements of hyperspectral absorption and attenuation coefficients collected onboard the R/V Tara can be used to evaluate near-surface estimates of chlorophyll-a, spectral particulate backscattering coefficients, particulate organic carbon, and particle size classes derived from the NASA Moderate Resolution Imaging Spectroradiometer onboard Aqua (MODISA). The predominant strength of such flow-through measurements is their sampling rate-the 375 days of measurements resulted in 165 viable MODISA-to-in situ match-ups, compared to 13 from discrete water sampling. While the need to apply bio-optical models to estimate biogeochemical quantities of interest from spectroscopy remains a weakness, we demonstrated how discrete samples can be used in combination with flow-through measurements to create data records of sufficient quality to conduct first order evaluations of satellite-derived data products. Given an emerging agency desire to rapidly evaluate new satellite missions, our results have significant implications on how calibration and validation teams for these missions will be constructed.

  18. Orbit Determination Strategy and Simulation Performance for OSIRIS-REx Proximity Operations

    NASA Technical Reports Server (NTRS)

    Leonard, Jason M.; Antreasian, Peter G.; Jackman, Coralie D.; Page, Brian; Wibben, Daniel R.; Moreau, Michael C.

    2017-01-01

    The Origins Spectral Interpretation Resource Identification Security Regolith Explorer (OSIRISREx)is a NASA New Frontiers mission to the near-earth asteroid Bennu that will rendez vousin 2018, create a comprehensive and detailed set of observations over several years, collect a regolith sample, and return the sample to Earth in 2023. The Orbit Determination (OD) team isa sub-section of the Flight Dynamics System responsible for generating precise reconstructions and predictions of the spacecraft trajectory. The OD team processes radiometric data, LIDAR, as well as center-finding and landmark-based Optical Navigation images throughout the proximity operations phase to estimate and predict the spacecraft location within several meters. Stringent knowledge requirements stress the OD teams concept of operations and procedures to produce verified and consistent high quality solutions for observation planning, maneuver planning, and onboard sequencing. This paper will provide insight into the OD concept of operations and summarize the OD performance expected during the approach and early proximity operation phases,based on our pre-encounter knowledge of Bennu. Strategies and methods used to compare and evaluate predicted and reconstructed solutions are detailed. The use of high fidelity operational tests during early 2017 will stress the teams concept of operations and ability to produce precise OD solutions with minimal turn-around delay.

  19. 77 FR 58979 - Proposed Information Collection; Comment Request; Direct Investment Surveys: BE-15, Annual Survey...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-25

    ... Request; Direct Investment Surveys: BE-15, Annual Survey of Foreign Direct Investment in the United States... to David H. Galler, Chief, Direct Investment Division (BE- 50), Bureau of Economic Analysis, U.S... Investment in the United States (Form BE-15) obtains sample data on the financial structure and operations of...

  20. Software Engineering Laboratory (SEL) Data Base Maintenance System (DBAM) user's guide and system description

    NASA Technical Reports Server (NTRS)

    Lo, P. S.; Card, D.

    1983-01-01

    The Software Engineering Laboratory (SEL) Data Base Maintenance System (DBAM) is explained. The various software facilities of the SEL, DBAM operating procedures, and DBAM system information are described. The relationships among DBAM components (baseline diagrams), component descriptions, overlay descriptions, indirect command file listings, file definitions, and sample data collection forms are provided.

  1. Evolution of Biomedical Research During Combat Operations

    DTIC Science & Technology

    2013-08-01

    Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited. Report Documentation Page Form ApprovedOMB No. 0704-0188...2Hatzfeld et al. S116 * 2013 Lippincott Williams & Wilkins Copyright © 2013 Lippincott Williams & Wilkins. Unauthorized reproduction of this article is...N = 300 Data/samples collected Clinical data Clinical data Clinical data Neuropsychological tests Quantitative electroencephalogram In-theater

  2. Best management practices for erosion control from bladed skid trails

    Treesearch

    Charles R. Wade; W. Michael Aust; M. Chad Bolding; William A. Lakel III

    2012-01-01

    Sediment from forest operations is primarily associated with roads and skid trails. We evaluated five skid trail closure treatments applied to bladed skid trails in the Virginia Piedmont. Closure treatments were Waterbars, Seed, Mulch, Pine slash, and Hardwood slash. Sediment traps were used to collect monthly sediment samples for one year. The Mulch, Pine slash, and...

  3. Environmental Fate and Impacts of Sulfometuron on Watersheds in the Southern United States

    Treesearch

    J.L. Michael

    2003-01-01

    Dissipation of sulfometuron (SM), methyl 2-[[[[(4,6-diiethyl-2-pyrimidinyl)amino]carbonyl]amino]sulfonyl] benzoate, in streamflow, sediment, plant tissue, litter, and soil following operational forestry applications at the target rate of 0.42 kg a.i. ha-1 was monitored. Streamflow samples were collected at a weir on the perimeter and 30...

  4. Collaborative School Turnaround: A Study of the Impact of School Federations on Student Outcomes

    ERIC Educational Resources Information Center

    Chapman, Christopher; Muijs, Daniel

    2013-01-01

    School federations are groups of two or more schools operating under a single governance structure. The study reported in this article compared federations designed to raise performance in low-attaining schools against a matched sample of their non-federated counterparts. The findings are based on quantitative analysis of data collected in…

  5. Special Report on the Data Collection Programs for the Ground Based Nitrogen Washout Experiment. Volume 2 - Detailed Program Descriptions, Listings, Examples and Hardware Specifications

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Personal data input, decompression data, nitrogen washout, nitrogen data, and update computer programs are described. Input data and formats; program output, reports, and data; program flowcharts; program listings; sample runs with input and output pages; hardware operation; and engineering data are provided.

  6. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FIELD USE OF THE MODIFIED AIR SENTINEL (UA-F-10.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the in-field use of the modified Air Sentinel. Samples collected with this Hi-Vol instrument were analyzed for atmospheric concentrations of target metals. This procedure was followed to ensure consistent data retrieval of air and dust ana...

  7. National Pollutant Discharge Elimination System (NPDES) Permit Application Requirement for Storm Water Discharges

    DTIC Science & Technology

    1991-05-01

    schedule for construction, upgrading or operation of wastewater treatment facilities or any other environmental programs, which may effect storm water quality of...if the storm water quality may be similar. c. Two sets of samples are required to be collected: (1) A grab during the first 30 minutes of the rainfall

  8. Total airborne mold particle sampling: evaluation of sample collection, preparation and counting procedures, and collection devices.

    PubMed

    Godish, Diana; Godish, Thad

    2008-02-01

    This study was conducted to evaluate (i) procedures used to collect, prepare, and count total airborne mold spore/particle concentrations, and (ii) the relative field performance of three commercially available total airborne mold spore/particle sampling devices. Differences between factory and laboratory airflow calibration values of axial fan-driven sampling instruments (used in the study) indicated a need for laboratory calibration using a mass flow meter to ensure that sample results were accurately calculated. An aniline blue-amended Calberla's solution adjusted to a pH of 4.2-4.4 provided good sample mounting/counting results using Dow Corning high vacuum grease, Dow Corning 280A adhesive, and Dow Corning 316 silicone release spray for samples collected using mini-Burkard and Allergenco samplers. Count variability among analysts was most pronounced in 5% counts of relatively low mold particle deposition density samples and trended downward with increased count percentage and particle deposition density. No significant differences were observed among means of 5, 10, and 20% counts and among analysts; a significant interaction effect was observed between analysts' counts and particle deposition densities. Significantly higher mini-Burkard and Air-O-Cell total mold spore/particle counts for 600x vs. 400x (1.9 and 2.3 x higher, respectively), 1000x vs. 600x (1.9 and 2.2 x higher, respectively) and 1000x vs. 400x (3.6 and 4.6 x higher, respectively) comparisons indicated that 1000x magnification counts best quantified total airborne mold spore/particles using light microscopy, and that lower magnification counts may result in unacceptable underreporting of airborne mold spore/particle concentrations. Modest but significantly higher (1.2x) total mold spore concentrations were observed with Allergenco vs. mini-Burkard samples collected in co-located, concurrently operated sampler studies; moderate but significantly higher mini-Burkard count values (1.4x) were observed in similar studies with Air-O-Cell samplers. These count differences were relatively small compared with the large differences observed among three count magnifications.

  9. Biases encountered in long-term monitoring studies of invertebrates and microflora: Australian examples of protocols, personnel, tools and site location.

    PubMed

    Greenslade, Penelope; Florentine, Singarayer K; Hansen, Brigita D; Gell, Peter A

    2016-08-01

    Monitoring forms the basis for understanding ecological change. It relies on repeatability of methods to ensure detected changes accurately reflect the effect of environmental drivers. However, operator bias can influence the repeatability of field and laboratory work. We tested this for invertebrates and diatoms in three trials: (1) two operators swept invertebrates from heath vegetation, (2) four operators picked invertebrates from pyrethrum knockdown samples from tree trunk and (3) diatom identifications by eight operators in three laboratories. In each trial, operators were working simultaneously and their training in the field and laboratory was identical. No variation in catch efficiency was found between the two operators of differing experience using a random number of net sweeps to catch invertebrates when sequence, location and size of sweeps were random. Number of individuals and higher taxa collected by four operators from tree trunks varied significantly between operators and with their 'experience ranking'. Diatom identifications made by eight operators were clustered together according to which of three laboratories they belonged. These three tests demonstrated significant potential bias of operators in both field and laboratory. This is the first documented case demonstrating the significant influence of observer bias on results from invertebrate field-based studies. Examples of two long-term trials are also given that illustrate further operator bias. Our results suggest that long-term ecological studies using invertebrates need to be rigorously audited to ensure that operator bias is accounted for during analysis and interpretation. Further, taxonomic harmonisation remains an important step in merging field and laboratory data collected by different operators.

  10. Effects of Specimen Collection Methodologies and Storage Conditions on the Short-Term Stability of Oral Microbiome Taxonomy.

    PubMed

    Luo, Ting; Srinivasan, Usha; Ramadugu, Kirtana; Shedden, Kerby A; Neiswanger, Katherine; Trumble, Erika; Li, Jiean J; McNeil, Daniel W; Crout, Richard J; Weyant, Robert J; Marazita, Mary L; Foxman, Betsy

    2016-09-15

    Community profiling of the oral microbiome requires the recovery of quality sequences in order to accurately describe microbial community structure and composition. Our objective was to assess the effects of specimen collection method, storage medium, and storage conditions on the relative abundance of taxa in saliva and plaque identified using 16S rRNA genes. We also assessed short-term changes in taxon composition and relative abundance and compared the salivary and dental plaque communities in children and adults. Over a 2-week period, four successive saliva and dental plaque specimens were collected from four adults with no dental decay (108 samples), and two successive specimens were collected from six children with four or more erupted teeth (48 samples). There were minimal differences in community composition at the phylum and operational taxonomic unit levels between dental plaque collection using a scaler and collection using a CytoSoft brush. Plaque samples stored in OMNIgene medium showed higher within-sample Shannon diversity, were compositionally different, and were more similar to each other than plaque stored in liquid dental transport medium. Saliva samples stored in OMNIgene recovered similar communities for at least a week following storage at room temperature. However, the microbial communities recovered from plaque and saliva stored in OMNIgene were significantly different in composition from their counterparts stored in liquid dental transport medium. Dental plaque communities collected from the same tooth type over four successive visits from the same adult did not significantly differ in structure or composition. Large-scale epidemiologic studies require collection over time and space, often with multiple teams collecting, storing, and processing data. Therefore, it is essential to understand how sensitive study results are to modest changes in collection and storage protocols that may occur with variation in personnel, resources available at a study site, and shipping requirements. The research presented in this paper measures the effects of multiple storage parameters and collection methodologies on the measured ecology of the oral microbiome from healthy adults and children. These results will potentially enable investigators to conduct oral microbiome studies at maximal efficiency by guiding informed administrative decisions pertaining to the necessary field or clinical work. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  11. Effects of Specimen Collection Methodologies and Storage Conditions on the Short-Term Stability of Oral Microbiome Taxonomy

    PubMed Central

    Luo, Ting; Srinivasan, Usha; Ramadugu, Kirtana; Shedden, Kerby A.; Neiswanger, Katherine; Trumble, Erika; Li, Jiean J.; McNeil, Daniel W.; Crout, Richard J.; Weyant, Robert J.; Marazita, Mary L.

    2016-01-01

    ABSTRACT Community profiling of the oral microbiome requires the recovery of quality sequences in order to accurately describe microbial community structure and composition. Our objective was to assess the effects of specimen collection method, storage medium, and storage conditions on the relative abundance of taxa in saliva and plaque identified using 16S rRNA genes. We also assessed short-term changes in taxon composition and relative abundance and compared the salivary and dental plaque communities in children and adults. Over a 2-week period, four successive saliva and dental plaque specimens were collected from four adults with no dental decay (108 samples), and two successive specimens were collected from six children with four or more erupted teeth (48 samples). There were minimal differences in community composition at the phylum and operational taxonomic unit levels between dental plaque collection using a scaler and collection using a CytoSoft brush. Plaque samples stored in OMNIgene medium showed higher within-sample Shannon diversity, were compositionally different, and were more similar to each other than plaque stored in liquid dental transport medium. Saliva samples stored in OMNIgene recovered similar communities for at least a week following storage at room temperature. However, the microbial communities recovered from plaque and saliva stored in OMNIgene were significantly different in composition from their counterparts stored in liquid dental transport medium. Dental plaque communities collected from the same tooth type over four successive visits from the same adult did not significantly differ in structure or composition. IMPORTANCE Large-scale epidemiologic studies require collection over time and space, often with multiple teams collecting, storing, and processing data. Therefore, it is essential to understand how sensitive study results are to modest changes in collection and storage protocols that may occur with variation in personnel, resources available at a study site, and shipping requirements. The research presented in this paper measures the effects of multiple storage parameters and collection methodologies on the measured ecology of the oral microbiome from healthy adults and children. These results will potentially enable investigators to conduct oral microbiome studies at maximal efficiency by guiding informed administrative decisions pertaining to the necessary field or clinical work. PMID:27371581

  12. The Antarctic Search for Meteorites: The Future of Space, on Earth Today - EVA Knowledge Capture Outbrief

    NASA Technical Reports Server (NTRS)

    Love, Stan

    2013-01-01

    NASA astronaut Stan Love shared his experiences with the Antarctic Search for Meteorites (ANSMET), an annual expedition to the southern continent to collect valuable samples for research in planetary science. ANSMET teams operate from isolated, remote field camps on the polar plateau, where windchill factors often reach -40 F. Several astronaut participants have noted ANSMET's similarity to a space mission. Some of the operational concepts, tools, and equipment employed by ANSMET teams may offer valuable insights to designers of future planetary surface exploration hardware.

  13. Measuring Charge Collection Efficiency in Diamond Vertex Detectors

    NASA Astrophysics Data System (ADS)

    Josey, Brian; Seidel, Sally; Hoeferkamp, Martin

    2011-10-01

    As currently used at the Large Hadron Collider, vertex detectors are composed primarily of silicon sensors that image particle tracks by detecting the creation of electron-hole pairs caused by the excitation of the silicon atoms. We are investigating replacing these silicon detectors with detectors made out of diamond. Diamond is advantageous due to its radiation hardness. We are measuring the charge collection efficiency of diamond as a function of fluence. We are building a characterization station. Diamond samples will be placed into the characterization station and exposed to a strontium-90 beta source, before and after I irradiate them with 800 MeV protons at LANL. The radiation from the Sr-90 source will create electron-hole pairs. These will be read out by applying an electric field across the sample. The system is triggered by a scintillator-photomultiplier tube assembly. The goal of this measurement is to record collected charge as a function of bias voltage. The diamond charge collection data will be compared to silicon and predictions about detector operation at the LHC will be made.

  14. Curating NASA's future extraterrestrial sample collections: How do we achieve maximum proficiency?

    NASA Astrophysics Data System (ADS)

    McCubbin, Francis; Evans, Cynthia; Allton, Judith; Fries, Marc; Righter, Kevin; Zolensky, Michael; Zeigler, Ryan

    2016-07-01

    Introduction: The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10E "Curation of Extraterrestrial Materials", JSC is charged with "The curation of all extraterrestrial material under NASA control, including future NASA missions." The Directive goes on to define Curation as including "…documentation, preservation, preparation, and distribution of samples for research, education, and public outreach." Here we describe some of the ongoing efforts to ensure that the future activities of the NASA Curation Office are working to-wards a state of maximum proficiency. Founding Principle: Curatorial activities began at JSC (Manned Spacecraft Center before 1973) as soon as design and construction planning for the Lunar Receiving Laboratory (LRL) began in 1964 [1], not with the return of the Apollo samples in 1969, nor with the completion of the LRL in 1967. This practice has since proven that curation begins as soon as a sample return mission is conceived, and this founding principle continues to return dividends today [e.g., 2]. The Next Decade: Part of the curation process is planning for the future, and we refer to these planning efforts as "advanced curation" [3]. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of collections as envisioned by NASA exploration goals. We are (and have been) planning for future curation, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, curation of organically- and biologically-sensitive samples, and the use of minimally invasive analytical techniques (e.g., micro-CT, [4]) to characterize samples. These efforts will be useful for Mars Sample Return, Lunar South Pole-Aitken Basin Sample Return, and Comet Surface Sample Return, all of which were named in the NRC Planetary Science Decadal Survey 2013-2022. We are fully committed to pushing the boundaries of curation protocol as humans continue to push the boundaries of space exploration and sample return. However, to improve our ability to curate astromaterials collections of the future and to provide maximum protection to any returned samples, it is imperative that curation involvement commences at the time of mission conception. When curation involvement is at the ground floor of mission planning, it provides a mechanism by which the samples can be protected against project-level decisions that could undermine the scientific value of the re-turned samples. A notable example of one of the bene-fits of early curation involvement in mission planning is in the acquisition of contamination knowledge (CK). CK capture strategies are designed during the initial planning stages of a sample return mission, and they are to be implemented during all phases of the mission from assembly, test, and launch operations (ATLO), through cruise and mission operations, to the point of preliminary examination after Earth return. CK is captured by witness materials and coupons exposed to the contamination environment in the assembly labs and on the space craft during launch, cruise, and operations. These materials, along with any procedural blanks and returned flight-hardware, represent our CK capture for the returned samples and serves as a baseline from which analytical results can be vetted. Collection of CK is a critical part of being able to conduct and interpret data from organic geochemistry and biochemistry investigations of returned samples. The CK samples from a given mission are treated as part of the sample collection of that mission, hence they are part of the permanent archive that is maintained by the NASA curation Office. We are in the midst of collecting witness plates and coupons for the OSIRIS-REx mission, and we are in the planning stages for similar activities for the Mars 2020 rover mission, which is going to be the first step in a multi-stage campaign to return martian samples to Earth. Concluding Remarks: The return of every extraterrestrial sample is a scientific investment, and the CK samples and any procedural blanks represent an insurance policy against imperfections in the sample-collection and sample-return process. The curation facilities and personnel are the primary managers of that investment, and the scientific community, at large, is the beneficiary. The NASA Curation Office at JSC has the assigned task of maintaining the long-term integrity of all of NASA's astromaterials and ensuring that the samples are distributed for scientific study in a fair, timely, and responsible manner. It is only through this openness and global collaboration in the study of astromaterials that the return on our scientific investments can be maximized. For information on requesting samples and becoming part of the global study of astromaterials, please visit curator.jsc.nasa.gov References: [1] Mangus, S. & Larsen, W. (2004) NASA/CR-2004-208938, NASA, Washington, DC. [2] Allen, C. et al., (2011) Chemie Der Erde-Geochemistry, 71, 1-20. [3] McCubbin, F.M. et al., (2016) 47th LPSC #2668. [4] Zeigler, R.A. et al., (2014) 45th LPSC #2665.

  15. Contamination source review for Building E5485, Edgewood Area, Aberdeen Proving Ground, Maryland

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Billmark, K.A.; Hayes, D.C.; Draugelis, A.K.

    1995-09-01

    This report was prepared by Argonne National Laboratory (ANL) to document the results of a contamination source review of Building E5485 at the Aberdeen Proving Ground (APG) in Maryland. This report may be used to assist the US Army in planning for the future use or disposition of this building. The review included a historical records search, physical inspection, photographic documentation, geophysical investigation, and collection of air samples. Building E5485 (APG designation) is located in the drainage basin of the west branch of Canal Creek in the Edgewood Area of APG. The building was constructed in 1922 and used asmore » a fan house for agent operations in Building E5487 from 1925 to 1966. Building E5485 was then used as a laboratory to support manufacturing and storage of flammable agents and chemical warfare agents from 1966 until 1967, when it was placed on the inactive list. Air quality samples were collected upwind, downwind, and inside Building E5485 in November 1994. Analytical results showed no distinguishable difference in hydrocarbon and chlorinated solvent levels between the two background samples and the sample collected inside Building E5485. These results indicate that Building E5485 is not a source of volatile organic compound contamination.« less

  16. Inequalities in microbial contamination of drinking water supplies in urban areas: the case of Lilongwe, Malawi.

    PubMed

    Boakye-Ansah, Akosua Sarpong; Ferrero, Giuliana; Rusca, Maria; van der Zaag, Pieter

    2016-10-01

    Over past decades strategies for improving access to drinking water in cities of the Global South have mainly focused on increasing coverage, while water quality has often been overlooked. This paper focuses on drinking water quality in the centralized water supply network of Lilongwe, the capital of Malawi. It shows how microbial contamination of drinking water is unequally distributed to consumers in low-income (unplanned areas) and higher-income neighbourhoods (planned areas). Microbial contamination and residual disinfectant concentration were measured in 170 water samples collected from in-house taps in high-income areas and from kiosks and water storage facilities in low-income areas between November 2014 and January 2015. Faecal contamination (Escherichia coli) was detected in 10% of the 40 samples collected from planned areas, in 59% of the 64 samples collected from kiosks in the unplanned areas and in 75% of the 32 samples of water stored at household level. Differences in water quality in planned and unplanned areas were found to be statistically significant at p < 0.05. Finally, the paper shows how the inequalities in microbial contamination of drinking water are produced by decisions both on the development of the water supply infrastructure and on how this is operated and maintained.

  17. Increasing Intelligence, Surveillance, and Reconnaissance (ISR) Operational Agility through Mission Command

    DTIC Science & Technology

    2016-06-10

    Counterinsurgency COM Collections Operations Management CONOP Concept of Operations CRM Collections Requirements Management DOD Department of...collection requirements management ( CRM ) and collection operations management (COM). CRM is the authoritative development and control of collection...management ( CRM ) and collections operations management (COM) (see figure 6). In general, CRM advocates and prioritizes customer requirements while

  18. Feasibility of conducting wetfall chemistry investigations around the Bowen Power Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, N.C.J.; Patrinos, A.A.N.

    1979-10-01

    The feasibility of expanding the Meteorological Effects of Thermal Energy Releases - Oak Ridge National Laboratory (METER-ORNL) research at Bower Power Plant, a coal-fired power plant in northwest Georgia, to include wetfall chemistry is evaluated using results of similar studies around other power plants, several atmospheric washout models, analysis of spatial variability in precipitation, and field logistical considerations. An optimal wetfall chemistry network design is proposed, incorporating the inner portion of the existing rain-gauge network and augmented by additional sites to ensure adequate coverage of probable target areas. The predicted sulfate production rate differs by about four orders of magnitudemore » among the models reviewed with a pH of 3. No model can claim superiority over any other model without substantive data verification. The spatial uniformity in rain amount is evaluated using four storms that occurred at the METER-ORNL network. Values of spatial variability ranged from 8 to 31% and decreased as the mean rainfall increased. The field study of wetfall chemistry will require a minimum of 5 persons to operate the approximately 50 collectors covering an area of 740 km/sup 2/. Preliminary wetfall-only samples collected on an event basis showed lower pH and higher electrical conductivity of precipitation collected about 5 km downwind of the power plant relative to samples collected upwind. Wetfall samples collected on a weekly basis using automatic samplers, however, showed variable results, with no consistent pattern. This suggests the need for event sampling to minimize variable rain volume and multiple-source effects often associated with weekly samples.« less

  19. A Constrained and Versioned Data Model for TEAM Data

    NASA Astrophysics Data System (ADS)

    Andelman, S.; Baru, C.; Chandra, S.; Fegraus, E.; Lin, K.

    2009-04-01

    The objective of the Tropical Ecology Assessment and Monitoring Network (www.teamnetwork.org) is "To generate real time data for monitoring long-term trends in tropical biodiversity through a global network of TEAM sites (i.e. field stations in tropical forests), providing an early warning system on the status of biodiversity to effectively guide conservation action". To achieve this, the TEAM Network operates by collecting data via standardized protocols at TEAM Sites. The standardized TEAM protocols include the Climate, Vegetation and Terrestrial Vertebrate Protocols. Some sites also implement additional protocols. There are currently 7 TEAM Sites with plans to grow the network to 15 by June 30, 2009 and 50 TEAM Sites by the end of 2010. At each TEAM Site, data is gathered as defined by the protocols and according to a predefined sampling schedule. The TEAM data is organized and stored in a database based on the TEAM spatio-temporal data model. This data model is at the core of the TEAM Information System - it consumes and executes spatio-temporal queries, and analytical functions that are performed on TEAM data, and defines the object data types, relationships and operations that maintain database integrity. The TEAM data model contains object types including types for observation objects (e.g. bird, butterfly and trees), sampling unit, person, role, protocol, site and the relationship of these object types. Each observation data record is a set of attribute values of an observation object and is always associated with a sampling unit, an observation timestamp or time interval, a versioned protocol and data collectors. The operations on the TEAM data model can be classified as read operations, insert operations and update operations. Following are some typical operations: The operation get(site, protocol, [sampling unit block, sampling unit,] start time, end time) returns all data records using the specified protocol and collected at the specified site, block, sampling unit and time range. The operation insertSamplingUnit(sampling unit, site, protocol) saves a new sampling unit into the data model and links it with the site and protocol. The operation updateSampligUnit(sampling_unit_id, attribute, value) changes the attribute (e.g. latitude or longitude) of the sampling unit to the specified value. The operation insertData(observation record, site, protocol, sampling unit, timestamps, data collectors) saves a new observation record into the database and associates it with specified objects. The operation updateData(protocol, data_id, attribute, value) modifies the attribute of an existing observation record to the specified value. All the insert or update operations require: 1) authorization to ensure the user has necessary privileges to perform the operation; 2) timestamp validation to ensure the observation timestamps are in the designated time range specified in the sampling schedule; 3) data validation to check that the data records use correct taxonomy terms and data values. No authorization is performed for get operations, but under some specific condition, a username may be required for the purpose of authentication. Along with the validations above, the TEAM data model also supports human based data validation on observed data through the Data Review subsystem to ensure data quality. The data review is implemented by adding two attributes review_tag and review_comment to each observation data record. The attribute review_tag is used by a reviewer to specify the quality of data, and the attribute review_comment is for reviewers to give more information when a problem is identified. The review_tag attribute can be populated by either the system conducting QA/QC tests or by pre-specified scientific experts. The following is the review operation, which is actually a special case of the operation updateData: The operation updateReview(protocol, data_id, judgment, comment) sets the attribute review_tag and review_comment to the specified values. By systematically tracking every step, The TEAM data model can roll back to any previous state. This is achieved by introducing a historical data container for each editable object type. When the operation updateData is applied to an object to modify its attribute, the object will be tagged with the current timestamp and the name of the user who conducts the operation, the tagged object will then be moved into the historical data container, and finally a new object will be created with the new value for the specified attribute. The diagram illustrates the architecture of the TEAM data management system. A data collector can use the Data Ingestion subsystem to load new data records into the TEAM data model. The system establishes a first level of review (i.e. meets minimum data standards via QA/QC tests). Further review is done via experts and they can verify and provide their comments on data records through the Data Review subsystem. The data editor can then address data records based on the reviewer's comments. Users can use the Data Query and Download application to find data by sites, protocols and time ranges. The Data Query and Download system packages selected data with the data license and important metadata information into a single package and delivers it to the user.

  20. Mutagenicity and in vivo toxicity of combined particulate and semivolatile organic fractions of gasoline and diesel engine emissions.

    PubMed

    Seagrave, JeanClare; McDonald, Jacob D; Gigliotti, Andrew P; Nikula, Kristen J; Seilkop, Steven K; Gurevich, Michael; Mauderly, Joe L

    2002-12-01

    Exposure to engine emissions is associated with adverse health effects. However, little is known about the relative effects of emissions produced by different operating conditions, fuels, or technologies. Rapid screening techniques are needed to compare the biological effects of emissions with different characteristics. Here, we examined a set of engine emission samples using conventional bioassays. The samples included combined particulate material and semivolatile organic compound fractions of emissions collected from normal- and high-emitter gasoline and diesel vehicles collected at 72 degrees F, and from normal-emitter groups collected at 30 degrees F. The relative potency of the samples was determined by statistical analysis of the dose-response curves. All samples induced bacterial mutagenicity, with a 10-fold range of potency among the samples. Responses to intratracheal instillation in rats indicated generally parallel rankings of the samples by multiple endpoints reflecting cytotoxic, inflammatory, and lung parenchymal changes, allowing selection of a more limited set of parameters for future studies. The parameters selected to assess oxidative stress and macrophage function yielded little useful information. Responses to instillation indicated little difference in potency per unit of combined particulate material and semivolatile organic compound mass between normal-emitter gasoline and diesel vehicles, or between emissions collected at different temperatures. However, equivalent masses of emissions from high-emitter vehicles of both types were more potent than those from normal-emitters. While preliminary in terms of assessing contributions of different emissions to health hazards, the results indicate that a subset of this panel of assays will be useful in providing rapid, cost-effective feedback on the biological impact of modified technology.

Top