Shelton, Larry R.
1994-01-01
The U.S. Geological Survey's National Water-Quality Assessment program includes extensive data- collection efforts to assess the quality of the Nations's streams. These studies require analyses of stream samples for major ions, nutrients, sediments, and organic contaminants. For the information to be comparable among studies in different parts of the Nation, consistent procedures specifically designed to produce uncontaminated samples for trace analysis in the laboratory are critical. This field guide describes the standard procedures for collecting and processing samples for major ions, nutrients, organic contaminants, sediment, and field analyses of conductivity, pH, alkalinity, and dissolved oxygen. Samples are collected and processed using modified and newly designed equipment made of Teflon to avoid contamination, including nonmetallic samplers (D-77 and DH-81) and a Teflon sample splitter. Field solid-phase extraction procedures developed to process samples for organic constituent analyses produce an extracted sample with stabilized compounds for more accurate results. Improvements to standard operational procedures include the use of processing chambers and capsule filtering systems. A modified collecting and processing procedure for organic carbon is designed to avoid contamination from equipment cleaned with methanol. Quality assurance is maintained by strict collecting and processing procedures, replicate sampling, equipment blank samples, and a rigid cleaning procedure using detergent, hydrochloric acid, and methanol.
The purpose of this SOP is to guide the collection, storage, and shipment of urine samples collected for the NHEXAS Arizona project. This SOP provides a brief description of sample, collection, preservation, storage, shipping, and custody procedures. This procedure was followed ...
The purpose of this SOP is to guide the collection, storage, and shipment of urine samples collected. This SOP provides a brief description of sample, collection, preservation, storage, shipping, and custody procedures. This procedure was followed to ensure consistent data retri...
The purpose of this SOP is to guide the collection, storage, and shipment of blood samples collected. This SOP provides a brief description of sample collection, preservation, storage, and custody procedures. This procedure was followed to ensure consistent data retrieval during...
The purpose of this SOP is to guide the collection, storage, and shipment of blood samples collected for the NHEXAS Arizona project. This SOP provides a brief description of sample collection, preservation, storage, and custody procedures. This procedure was followed to ensure c...
Sample Collection Procedures and Strategies
Individuals responsible for collecting environmental and building material samples following a contamination incident, can use these procedures to plan for and/or collect samples for analysis using the analytical methods listed in EPA's SAM
Evaluation of standardized sample collection, packaging, and ...
Journal Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures.
Manning, T.K.; Smith, K.E.; Wood, C.D.; Williams, J.B.
1994-01-01
Water-quality samples were collected from Chicod Creek in the Coastal Plain Province of North Carolina during the summer of 1992 as part of the U.S. Geological Survey's National Water-Quality Assessment Program. Chicod Creek is in the Albemarle-Pamlico drainage area, one of four study units designated to test equipment and procedures for collecting and processing samples for the solid-phase extraction of selected pesticides, The equipment and procedures were used to isolate 47 pesticides, including organonitrogen, carbamate, organochlorine, organophosphate, and other compounds, targeted to be analyzed by gas chromatography/mass spectrometry. Sample-collection and processing equipment equipment cleaning and set-up procedures, methods pertaining to collecting, splitting, and solid-phase extraction of samples, and water-quality data resulting from the field test are presented in this report Most problems encountered during this intensive sampling exercise were operational difficulties relating to equipment used to process samples.
The purpose of this SOP is to establish a uniform procedure for the collection of yard composite soil samples in the field. This procedure was followed to ensure consistent and reliable collection of outdoor soil samples during the Arizona NHEXAS project and the "Border" study. ...
The purpose of this SOP is to establish a uniform procedure for the collection of residential foundation soil samples in the field. This procedure was followed to ensure consistent and reliable collection of outdoor soil samples during the Arizona NHEXAS project and the "Border"...
The purpose of this SOP is to establish a uniform procedure for the collection of yard composite soil samples in the field. This procedure was followed to ensure consistent and reliable collection of outdoor soil samples during the Arizona NHEXAS project and the Border study. Ke...
Colling Wipe Samples for VX Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koester, C; Hoppes, W G
2010-02-11
This standard operating procedure (SOP) provides uniform procedures for the collection of wipe samples of VX residues from surfaces. Personnel may use this procedure to collect and handle wipe samples in the field. Various surfaces, including building materials (wood, metal, tile, vinyl, etc.) and equipment, may be sampled based on this procedure. The purpose of such sampling is to determine whether or not the relevant surfaces are contaminated, to determine the extent of their contamination, to evaluate the effectiveness of decontamination procedures, and to determine the amount of contaminant that might present as a contact hazard.
The purpose of this SOP is to provide a uniform procedure for the financial reimbursement of primary respondents for the collection of diet samples. Respondents were reimbursed for replicate food and beverage samples by type and amount collected over a 24-hour sampling period. ...
The purpose of this SOP is to provide a uniform procedure for the financial reimbursement of primary respondents for the collection of diet samples. Respondents were reimbursed for replicate food and beverage samples by type and amount collected over a 24-hour sampling period. ...
The purpose of this SOP is to establish a uniform procedure for the collection of indoor floor dust samples in the field. This procedure was followed to ensure consistent data retrieval of dust samples during the Arizona NHEXAS project and the "Border" study. Keywords: field; va...
This protocol describes the procedures for the collection, storage, and shipping of human scalp hair samples for trace metals and arsenic or potential adduct analysis. Scalp hair samples were collected from each participant that agreed to provide the sample. Thinning shears were ...
The purpose of this SOP is to establish a uniform procedure for the collection of indoor floor dust samples in the field. This procedure was followed to ensure consistent data retrieval of dust samples during the Arizona NHEXAS project and the Border study. Keywords: field; vacu...
This SOP describes the method to collect transferable residues from indoor floor surfaces. The sampling procedures described are applicable to bare floors or covered floor surfaces, e.g., carpeting and vinyl flooring. The samples will be collected only in the day care centers o...
The purpose of this SOP is to describe the procedures for collection, storage, and shipment of urine samples for metal, pesticides, and creatinine analysis. Samples were collected on Days 2 and 8 of each Cycle. The Day 2 sample was analyzed for metals and creatinine. The Day 8...
The document is a recommended operating procedure, prepare or use in research activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). The procedure applies to the collection of gaseous grab samples from fossil fuel combustion sources for subsequent a...
This procedure summarizes the sample shipping procedures that have been described in the individual NHEXAS sample collection protocols. This procedure serves as a quick reference tool for the field staff when samples are prepared for shipment at the field lab/staging area. For ea...
Calfee, M. Worth; Tufts, Jenia; Meyer, Kathryn; McConkey, Katrina; Mickelsen, Leroy; Rose, Laura; Dowell, Chad; Delaney, Lisa; Weber, Angela; Morse, Stephen; Chaitram, Jasmine; Gray, Marshall
2016-01-01
Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures. Both decontamination procedures were quantitatively evaluated on three types of sample packaging materials (corrugated fiberboard, polystyrene foam, and polyethylene plastic), and two contamination mechanisms (wet or dry inoculums). Contaminant transfer results suggested that size-appropriate gloves should be worn by personnel, templates should not be taped to or removed from surfaces, and primary receptacles should be selected carefully. The decontamination tests indicated that wipe-based decontamination procedures may be more effective than spray-based procedures; efficacy was not influenced by material type but was affected by the inoculation method. Incomplete surface decontamination was observed in all tests with dry inoculums. This study provides a foundation for optimizing current B. anthracis response procedures to minimize contaminant exfiltration. PMID:27362274
Calfee, M Worth; Tufts, Jenia; Meyer, Kathryn; McConkey, Katrina; Mickelsen, Leroy; Rose, Laura; Dowell, Chad; Delaney, Lisa; Weber, Angela; Morse, Stephen; Chaitram, Jasmine; Gray, Marshall
2016-12-01
Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures. Both decontamination procedures were quantitatively evaluated on three types of sample packaging materials (corrugated fiberboard, polystyrene foam, and polyethylene plastic), and two contamination mechanisms (wet or dry inoculums). Contaminant transfer results suggested that size-appropriate gloves should be worn by personnel, templates should not be taped to or removed from surfaces, and primary receptacles should be selected carefully. The decontamination tests indicated that wipe-based decontamination procedures may be more effective than spray-based procedures; efficacy was not influenced by material type but was affected by the inoculation method. Incomplete surface decontamination was observed in all tests with dry inoculums. This study provides a foundation for optimizing current B. anthracis response procedures to minimize contaminant exfiltration.
Sampling protocol for post-landfall Deepwater Horizon oil release, Gulf of Mexico, 2010
Wilde, F.D.; Skrobialowski, S.C.; Hart, J.S.
2010-01-01
The protocols and procedures described in this report are designed to be used by U.S. Geological Survey (USGS) field teams for the collection of environmental data and samples in coastal areas affected by the 2010 Deepwater Horizon oil spill in the Gulf of Mexico. This sampling protocol focuses specifically on sampling for water, sediments, benthic invertebrates, and microorganisms (ambient bacterial populations) after shoreline arrival of petroleum-associated product on beach, barrier island, and wetland environments of the Gulf of Mexico coastal states. Deployment to sampling sites, site setup, and sample collection in these environments necessitates modifications to standard USGS sampling procedures in order to address the regulatory, logistical, and legal requirements associated with samples collected in oil-impacted coastal areas. This document, therefore, has been written as an addendum to the USGS National Field Manual for the Collection of Water-Quality Data (NFM) (http://pubs.water.usgs.gov/twri9A/), which provides the basis for training personnel in the use of standard USGS sampling protocols. The topics covered in this Gulf of Mexico oil-spill sampling protocol augment NFM protocols for field-deployment preparations, health and safety precautions, sampling and quality-assurance procedures, and decontamination requirements under potentially hazardous environmental conditions. Documentation procedures and maintenance of sample integrity by use of chain-of-custody procedures also are described in this protocol.
Surface Environmental Surveillance Procedures Manual
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanf, RW; Dirkes, RL
1990-02-01
This manual establishes the procedures for the collection of environmental samples and the performance of radiation surveys and other field measurements. Responsibilities are defined for those personnel directly involved in the collection of samples and the performance of field measurements.
The purpose of this SOP is to describe the procedures for collecting surface wipe samples inside a home for analysis of either metals or pesticides. This procedure covers the preparation of the surface wipe material and field activities. This protocol was followed to ensure con...
CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF URINE SAMPLES (SOP-2.14)
This SOP describes the method for collecting urine samples from the study participants (children and their primary caregivers). Urine samples will be approximate 48-hr collections, collected as spot urine samples accumulated over the 48-hr sampling period. If the household or da...
78 FR 43002 - Proposed Collection; Comment Request for Revenue Procedure 2004-29
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-18
... comments concerning statistical sampling in Sec. 274 Context. DATES: Written comments should be received on... INFORMATION: Title: Statistical Sampling in Sec. 274 Contest. OMB Number: 1545-1847. Revenue Procedure Number: Revenue Procedure 2004-29. Abstract: Revenue Procedure 2004-29 prescribes the statistical sampling...
Shelton, Larry R.
1997-01-01
For many years, stream samples for analysis of volatile organic compounds have been collected without specific guidelines or a sampler designed to avoid analyte loss. In 1996, the U.S. Geological Survey's National Water-Quality Assessment Program began aggressively monitoring urban stream-water for volatile organic compounds. To assure representative samples and consistency in collection procedures, a specific sampler was designed to collect samples for analysis of volatile organic compounds in stream water. This sampler, and the collection procedures, were tested in the laboratory and in the field for compound loss, contamination, sample reproducibility, and functional capabilities. This report describes that sampler and its use, and outlines field procedures specifically designed to provide contaminant-free, reproducible volatile organic compound data from stream-water samples. These guidelines and the equipment described represent a significant change in U.S. Geological Survey instructions for collecting and processing stream-water samples for analysis of volatile organic compounds. They are intended to produce data that are both defensible and interpretable, particularly for concentrations below the microgram-per-liter level. The guidelines also contain detailed recommendations for quality-control samples.
The purpose of this SOP is to describe the procedures for collecting surface wipe samples inside a home for analysis of either metals or pesticides. This procedure covers the preparation of the surface wipe material and field activities. This protocol was followed to ensure con...
The purpose of this SOP is to describe the procedures for collecting a dermal wipe sample from a participant's hands for the measurement of pesticide or metal residues on the skin. This procedure covers the preparation of the dermal wipe material and field activities. This prot...
Hatzell, H.H.; Oaksford, E.T.; Asbury, C.E.
1995-01-01
The implementation of design guidelines for the National Water-Quality Assessment (NAWQA) Program has resulted in the development of new sampling procedures and the modification of existing procedures commonly used in the Water Resources Division of the U.S. Geological Survey. The Georgia-Florida Coastal Plain (GAFL) study unit began the intensive data collection phase of the program in October 1992. This report documents the implementation of the NAWQA guidelines by describing the sampling design and procedures for collecting surface-water samples in the GAFL study unit in 1993. This documentation is provided for agencies that use water-quality data and for future study units that will be entering the intensive phase of data collection. The sampling design is intended to account for large- and small-scale spatial variations, and temporal variations in water quality for the study area. Nine fixed sites were selected in drainage basins of different sizes and different land-use characteristics located in different land-resource provinces. Each of the nine fixed sites was sampled regularly for a combination of six constituent groups composed of physical and chemical constituents: field measurements, major ions and metals, nutrients, organic carbon, pesticides, and suspended sediments. Some sites were also sampled during high-flow conditions and storm events. Discussion of the sampling procedure is divided into three phases: sample collection, sample splitting, and sample processing. A cone splitter was used to split water samples for the analysis of the sampling constituent groups except organic carbon from approximately nine liters of stream water collected at four fixed sites that were sampled intensively. An example of the sample splitting schemes designed to provide the sample volumes required for each sample constituent group is described in detail. Information about onsite sample processing has been organized into a flowchart that describes a pathway for each of the constituent groups.
The purpose of this SOP is to describe the procedure for sampling personal air for metals and pesticides during a predetermined time period. The SOP includes the set up of the samplers for collection of either a metals sample or a pesticides sample, the calibration and initial c...
75 FR 38871 - Proposed Collection; Comment Request for Revenue Procedure 2004-29
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-06
... comments concerning Revenue Procedure 2004-29, Statistical Sampling in Sec. 274 Context. DATES: Written... Internet, at [email protected] . SUPPLEMENTARY INFORMATION: Title: Statistical Sampling in Sec...: Revenue Procedure 2004-29 prescribes the statistical sampling methodology by which taxpayers under...
The purpose of this SOP is to describe the procedures for collecting a dermal wipe sample from a participant's hands for the measurement of pesticide or metal residues on the skin. This procedure covers the preparation of the dermal wipe material and field activities. This prot...
75 FR 53738 - Proposed Collection; Comment Request for Rev. Proc. 2007-35
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-01
... Revenue Procedure Revenue Procedure 2007-35, Statistical Sampling for purposes of Section 199. DATES... through the Internet, at [email protected] . SUPPLEMENTARY INFORMATION: Title: Statistical Sampling...: This revenue procedure provides for determining when statistical sampling may be used in purposes of...
Mass Spectrometric Rapid Diagnosis of Infectious Diseases.
1980-01-01
the analytical procedures to warrant reporting anew the whole analytical procedure. A. Sample Collection and Storage Procedure Urine samples were...positives or false-negatives. Next we have carried out a longitudinal study on urine samples obtained from groups of volunteer subjects vaccinated with...sterilization and storage procedures. 2. Developed new, simpler sample preparation techniques including one to handle tissue culture media. 3. Improved on the
28 CFR 812.4 - Collection procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... COLUMBIA COLLECTION AND USE OF DNA INFORMATION § 812.4 Collection procedures. (a) DNA samples will be... misdemeanor pursuant to section 4(a)(5) of the DNA Analysis Backlog Elimination Act of 2000 (42 U.S.C. 14135b...
28 CFR 812.4 - Collection procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... COLUMBIA COLLECTION AND USE OF DNA INFORMATION § 812.4 Collection procedures. (a) DNA samples will be... misdemeanor pursuant to section 4(a)(5) of the DNA Analysis Backlog Elimination Act of 2000 (42 U.S.C. 14135b...
28 CFR 812.4 - Collection procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... COLUMBIA COLLECTION AND USE OF DNA INFORMATION § 812.4 Collection procedures. (a) DNA samples will be... misdemeanor pursuant to section 4(a)(5) of the DNA Analysis Backlog Elimination Act of 2000 (42 U.S.C. 14135b...
28 CFR 812.4 - Collection procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... COLUMBIA COLLECTION AND USE OF DNA INFORMATION § 812.4 Collection procedures. (a) DNA samples will be... misdemeanor pursuant to section 4(a)(5) of the DNA Analysis Backlog Elimination Act of 2000 (42 U.S.C. 14135b...
28 CFR 812.4 - Collection procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... COLUMBIA COLLECTION AND USE OF DNA INFORMATION § 812.4 Collection procedures. (a) DNA samples will be... misdemeanor pursuant to section 4(a)(5) of the DNA Analysis Backlog Elimination Act of 2000 (42 U.S.C. 14135b...
The purpose of this SOP is to describe how to collect, store, and ship human hair for analysis of mercury. This SOP provides a brief description of the sample containers, collection, storage, shipping and custody procedures. This procedure was followed to ensure consistent data ...
The purpose of this SOP is to describe how to collect, store, and ship unknown substances for chemical analysis and identification. This SOP provides a brief description of the sample containers, collection, storage, shipping and custody procedures. This procedure was followed ...
Suhonen, Riitta; Stolt, Minna; Katajisto, Jouko; Leino-Kilpi, Helena
2015-12-01
To report a review of quality regarding sampling, sample and data collection procedures of empirical nursing research of ethical climate studies where nurses were informants. Surveys are needed to obtain generalisable information about topics sensitive to nursing. Methodological quality of the studies is of key concern, especially the description of sampling and data collection procedures. Methodological literature review. Using the electronic MEDLINE database, empirical nursing research articles focusing on ethical climate were accessed in 2013 (earliest-22 November 2013). Using the search terms 'ethical' AND ('climate*' OR 'environment*') AND ('nurse*' OR 'nursing'), 376 citations were retrieved. Based on a four-phase retrieval process, 26 studies were included in the detailed analysis. Sampling method was reported in 58% of the studies, and it was random in a minority of the studies (26%). The identification of target sample and its size (92%) was reported, whereas justification for sample size was less often given. In over two-thirds (69%) of the studies with identifiable response rate, it was below 75%. A variety of data collection procedures were used with large amount of missing data about the details of who distributed, recruited and collected the questionnaires. Methods to increase response rates were seldom described. Discussion about nonresponse, representativeness of the sample and generalisability of the results was missing in many studies. This review highlights the methodological challenges and developments that need to be considered in ensuring the use of valid information in developing health care through research findings. © 2015 Nordic College of Caring Science.
Soil Sampling Operating Procedure
EPA Region 4 Science and Ecosystem Support Division (SESD) document that describes general and specific procedures, methods, and considerations when collecting soil samples for field screening or laboratory analysis.
Sediment Sampling Operating Procedure
EPA Region 4 Science and Ecosystem Support Division (SESD) document that describes general and specific procedures, methods, and considerations when collecting sediment samples for field screening or laboratory analysis.
Soil Gas Sampling Operating Procedure
EPA Region 4 Science and Ecosystem Support Division (SESD) document that describes general and specific procedures, methods, and considerations when collecting soil gas samples for field screening or laboratory analysis.
Sample Collection Information Document for Pathogens and ...
Report This Sample Collection Information Document (SCID) provides general information for use by EPA and its contractors when collecting samples during environmental remediation following a homeland security event. The document is intended to be used with SAM, and to provide information needed for collection of samples to be analyzed using the specific methods and procedures listed in SAM Revision 5.0.*
Sample Collection Information Document for Chemical & ...
Report This Sample Collection Information Document (SCID) provides general information for use by EPA and its contractors when collecting samples during environmental remediation following a contamination incident. The document is intended to be used with SAM, and to provide information needed for collection of samples to be analyzed using the specific methods and procedures listed in SAM 2012 (EPA/600/R-12/555).
This procedure describes the process for collecting and analyzing blood and urine samples. The presence of chemical contaminants in biological specimens such as blood, urine, and hair represent a measure of the internal dose or body burden for a given individual derived from the ...
Field Branches Quality System and Technical Procedures: This document describes general and specific procedures, methods and considerations to be used and observed when collecting soil gas samples for field screening or laboratory analysis.
Sheldon, Elizabeth; Vo, Kim Chi; McIntire, Ramsey A; Aghajanova, Lusine; Zelenko, Zara; Irwin, Juan C; Giudice, Linda C
2011-05-01
To develop a standard operating procedure (SOP) for collection, transport, storage of human endometrial tissue and blood samples, subject and specimen annotation, and establishing sample priorities. The SOP synthesizes sound scientific procedures, the literature on ischemia research, sample collection and gene expression profiling, good laboratory practices, and the authors' experience of workflow and sample quality. The National Institutes of Health, University of California, San Francisco, Human Endometrial Tissue and DNA Bank. Women undergoing endometrial biopsy or hysterectomy for nonmalignant indications. Collecting, processing, storing, distributing endometrial tissue and blood samples under approved institutional review board protocols and written informed consent from participating subjects. Standard operating procedure. The SOP addresses rigorous and consistent subject annotation, specimen processing and characterization, strict regulatory compliance, and a reference for researchers to track collection and storage times that may influence their research. The comprehensive and systematic approach to the procurement of human blood and endometrial tissue in this SOP ensures the high quality, reliability, and scientific usefulness of biospecimens made available to investigators by the National Institutes of Health, University of California, San Francisco, Human Endometrial Tissue and DNA Bank. The detail and perspective in this SOP also provides a blueprint for implementation of similar collection programs at other institutions. Copyright © 2011 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
The purpose of this SOP is to provide a uniform procedure for the collection of a complete (all meals, snacks, and beverages), one-day (24 hour) duplicate diet sample from the primary respondent. Participants will keep a duplicate portion of all food consumed in a 24 hour period...
The purpose of this SOP is to provide a uniform procedure for the collection of a complete (all meals, snacks, and beverages), one-day (24 hour) duplicate diet sample from the primary respondent. Participants will keep a duplicate portion of all food consumed in a 24 hour period...
Young, Stacie T.M.; Ball, Marcael T.J.
2004-01-01
Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. This program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream. For this program, rainfall data were collected at two sites, continuous streamflow data at three sites, and water-quality data at five sites, which include the three streamflow sites. This report summarizes rainfall, streamflow, and water-quality data collected between July 1, 2003 and June 30, 2004. A total of 30 samples was collected over four storms during July 1, 2003 to June 30, 2004. In general, an attempt was made to collect grab samples nearly simultaneously at all five sites, and flow-weighted time-composite samples were collected at the three sites equipped with automatic samplers. However, all four storms were partially sampled because either not all stations were sampled or only grab samples were collected. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, copper, lead, and zinc). Grab samples were additionally analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Quality-assurance/quality-control samples, collected during storms and during routine maintenance, were also collected to verify analytical procedures and check the effectiveness of equipment-cleaning procedures.
The purpose of this SOP is to describe the procedures for checking the food collections with the food stated as consumed in the 24-Hour Food Diary. The sample is then packaged and shipped for further analysis. This procedure applies to the checking of food samples and shipment ...
The purpose of this SOP is to describe the procedures for checking the food collections with the food stated as consumed in the 24-Hour Food Diary. The sample is then packaged and shipped to the FDA for further analysis. This procedure applies to the checking of food samples an...
Pilot test of new roadside survey methodology for impaired driving
DOT National Transportation Integrated Search
2007-01-01
This study developed and tested procedures to enhance roadside survey procedures to include collecting and analyzing oral fluid and blood samples from the nighttime weekend driving population. Roadside surveys involve collecting information from a ra...
Youth Attitude Tracking Study II Wave 17 -- Fall 1986.
1987-06-01
decision, unless so designated by other official documentation. TABLE OF CONTENTS Page PREFACE ................................................. xi...Segmentation Analyses .......................... 2-7 .3. METHODOLOGY OF YATS II....................................... 3-1 A. Sampling Design Overview...Sampling Design , Estimation Procedures and Estimated Sampling Errors ................................. A-i Appendix B: Data Collection Procedures
40 CFR 761.286 - Sample size and procedure for collecting a sample.
Code of Federal Regulations, 2013 CFR
2013-07-01
... collecting a sample. 761.286 Section 761.286 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... On-Site Disposal of Bulk PCB Remediation Waste and Porous Surfaces in Accordance With § 761.61(a)(6... PCB remediation waste or porous surfaces, collect at least 20 milliliters of waste, or a portion of...
40 CFR 761.286 - Sample size and procedure for collecting a sample.
Code of Federal Regulations, 2011 CFR
2011-07-01
... collecting a sample. 761.286 Section 761.286 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... On-Site Disposal of Bulk PCB Remediation Waste and Porous Surfaces in Accordance With § 761.61(a)(6... PCB remediation waste or porous surfaces, collect at least 20 milliliters of waste, or a portion of...
40 CFR 761.286 - Sample size and procedure for collecting a sample.
Code of Federal Regulations, 2012 CFR
2012-07-01
... collecting a sample. 761.286 Section 761.286 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... On-Site Disposal of Bulk PCB Remediation Waste and Porous Surfaces in Accordance With § 761.61(a)(6... PCB remediation waste or porous surfaces, collect at least 20 milliliters of waste, or a portion of...
40 CFR 761.286 - Sample size and procedure for collecting a sample.
Code of Federal Regulations, 2014 CFR
2014-07-01
... collecting a sample. 761.286 Section 761.286 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... On-Site Disposal of Bulk PCB Remediation Waste and Porous Surfaces in Accordance With § 761.61(a)(6... PCB remediation waste or porous surfaces, collect at least 20 milliliters of waste, or a portion of...
Shelton, Larry R.; Capel, Paul D.
1994-01-01
A major component of the U.S. Geological Survey's National Water-Quality Assessment program is to assess the occurrence and distribution of trace elements and organic contaminants in streams. The first phase of the strategy for the assessment is to analyze samples of bed sediments from depositional zones. Fine-grained particles deposited in these zones are natural accumulators of trace elements and hydrophobic organic compounds. For the information to be comparable among studies in many different parts of the Nation, strategies for selecting stream sites and depositional zones are critical. Fine-grained surficial sediments are obtained from several depositional zones within a stream reach and composited to yield a sample representing average conditions. Sample collection and processing must be done consistently and by procedures specifically designed to separate the fine material into fractions that yield uncontaminated samples for trace-level analytes in the laboratory. Special coring samplers and other instruments made of Teflon are used for collection. Samples are processed through a 2.0-millimeter stainless-steel mesh sieve for organic contaminate analysis and a 63-micrometer nylon-cloth sieve for trace-element analysis. Quality assurance is maintained by strict collection and processing procedures, duplicate samplings, and a rigid cleaning procedure.
Sampling procedure for lake or stream surface water chemistry
Robert Musselman
2012-01-01
Surface waters collected in the field for chemical analyses are easily contaminated. This research note presents a step-by-step detailed description of how to avoid sample contamination when field collecting, processing, and transporting surface water samples for laboratory analysis.
The purpose of this SOP is to describe the procedures for pre-cleaning filters and polyurethane foam (PUF) plug prior to air sampling with these media. The sampling media are used for sampling indoor air, outdoor air, and personal air. This procedure was followed to ensure consi...
Schenk, Michael; Huppertz, Berthold; Obermayer-Pietsch, Barbara; Kastelic, Darja; Hörmann-Kröpfl, Martina; Weiss, Gregor
2017-02-01
The aim of the present study was to develop a standard operating procedure (SOP) for the collection, transport, and storage of human cumulus cells, follicular fluid, blood serum, seminal plasma, embryo culture supernatant, and embryo culture supernatant control obtained within the IVF process under approved protocols and written informed consent from participating patients. The SOP was developed at the Kinderwunsch Institut Schenk, Dobl, Austria, together with Biobank Graz of the Medical University of Graz, Austria. The SOP provides comprehensive details of laboratory procedures and sampling of the different fluids within the IVF process. Furthermore, information on sample coding, references of involved laboratory techniques (e.g., oocyte retrieval with a Steiner-TAN needle), ethical approvals, and biobanking procedures are presented. The result of the present study is a standard operating procedure. The SOP ensures a professional way for collection and scientific use of IVF samples by the Kinderwunsch Institut Schenk, Dobl, Austria, and Biobank Graz of the Medical University of Graz, Austria. It can be used as a template for other institutions to unify specimen collection procedures in the field of reproductive health research.
USGS/EPA collection protocol for bacterial pathogens in soil
Griffin, Dale W.; Shaefer, F.L.; Charlena Bowling,; Dino Mattorano,; Tonya Nichols,; Erin Silvestri,
2014-01-01
This Sample Collection Procedure (SCP) describes the activities and considerations for the collection of bacterial pathogens from representative surface soil samples (0-5 cm). This sampling depth can be reached without the use of a drill rig, direct-push technology, or other mechanized equipment. This procedure can be used in most soil types but is limited to sampling at or near the ground surface. This protocol has components for two different types of sampling applications: (1) typical sampling, when there is no suspicion of contamination (e.g., surveillance or background studies); and (2) in response to known or suspected accidental contamination (e.g., the presence of animal carcasses). This protocol does not cover sampling in response to a suspected bioterrorist or intentional release event. Surface material is removed to the required depth (0-5 cm) and clean trowel or 50 ml sample tube is used to collect the sample. Sample containers are sealed, bagged, and shipped to the laboratory for analysis. Associated documentation, including a Field Data Log and Chain-of-Custody are also included in this document.
Ford, Morgan A.; Zuellig, Robert E.; Walters, David M.; Bruce, James F.
2016-08-11
This report provides a table of site descriptions, sample information, and semiquantitative aquatic macroinvertebrate data from 105 samples collected between 2005 and 2007 from 7 stream sites within the Sand Creek and Medano Creek watersheds in Great Sand Dunes National Park and Preserve, Saguache County, Colorado. Additionally, a short description of sample collection methods and laboratory sample processing procedures is presented. These data were collected in anticipation of assessing the potential effects of fish toxicants on macroinvertebrates.
Commodity Movements on the Texas Highway System: Data Collection and Survey Results
DOT National Transportation Integrated Search
1991-11-01
This report presents the survey procedures used and data collected in the : development of commodity flow statistics for movements over Texas Highways. : Response rates, sampling procedures, questionnaire design and the types of data : provided by th...
Canon, Abbey J; Lauterbach, Nicholas; Bates, Jessica; Skoland, Kristin; Thomas, Paul; Ellingson, Josh; Ruston, Chelsea; Breuer, Mary; Gerardy, Kimberlee; Hershberger, Nicole; Hayman, Kristen; Buckley, Alexis; Holtkamp, Derald; Karriker, Locke
2017-06-15
OBJECTIVE To develop and evaluate a pyramid training method for teaching techniques for collection of diagnostic samples from swine. DESIGN Experimental trial. SAMPLE 45 veterinary students. PROCEDURES Participants went through a preinstruction assessment to determine their familiarity with the equipment needed and techniques used to collect samples of blood, nasal secretions, feces, and oral fluid from pigs. Participants were then shown a series of videos illustrating the correct equipment and techniques for collecting samples and were provided hands-on pyramid-based instruction wherein a single swine veterinarian trained 2 or 3 participants on each of the techniques and each of those participants, in turn, trained additional participants. Additional assessments were performed after the instruction was completed. RESULTS Following the instruction phase, percentages of participants able to collect adequate samples of blood, nasal secretions, feces, and oral fluid increased, as did scores on a written quiz assessing participants' ability to identify the correct equipment, positioning, and procedures for collection of samples. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that the pyramid training method may be a feasible way to rapidly increase diagnostic sampling capacity during an emergency veterinary response to a swine disease outbreak.
Characteristics and Use of Home Health Care by Men and Women Aged 65 and Over
... 96% (5). A detailed description of the sampling design, data collection, and procedures are available at: http: / / ... same definitions, instructions, and procedures. However, the probability design of NHHCS permits the calculation of sampling errors. ...
This SOP describes the method for collecting a floor dust sample from carpet. Dust samples will be collected in the room that the child uses most at home and/or at day care using a High Volume Small Surface Sampler (HVS3). In addition, participants will also be asked to donate a ...
This SOP describes the method for collecting soil samples from the child's outdoor play area to measure for persistent organic pollutants. Soil samples are collected by scraping up the top 0.5 cm of soil in a 0.095 m2 (1 ft2) area in the middle of the child's play area.
Through a Regional Applied Research Effort grant to the United States Geological Survey, Region 9 collaborated with ORD on this project to develop a standard operating procedure for collection of water and sediment samples for pyrethroid analysis.
40 CFR 60.496 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Surface Coating Industry § 60.496 Test methods and procedures. (a) The reference methods in appendix A to...) Method 4 for stack gas moisture. (b) For Method 24, the coating sample must be a 1-litre sample collected... volume must be 0.003 dscm except that shorter sampling times or smaller volumes, when necessitated by...
40 CFR 60.496 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Surface Coating Industry § 60.496 Test methods and procedures. (a) The reference methods in appendix A to...) Method 4 for stack gas moisture. (b) For Method 24, the coating sample must be a 1-litre sample collected... volume must be 0.003 dscm except that shorter sampling times or smaller volumes, when necessitated by...
40 CFR 60.496 - Test methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Surface Coating Industry § 60.496 Test methods and procedures. (a) The reference methods in appendix A to...) Method 4 for stack gas moisture. (b) For Method 24, the coating sample must be a 1-litre sample collected... volume must be 0.003 dscm except that shorter sampling times or smaller volumes, when necessitated by...
40 CFR 60.496 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Surface Coating Industry § 60.496 Test methods and procedures. (a) The reference methods in appendix A to...) Method 4 for stack gas moisture. (b) For Method 24, the coating sample must be a 1-litre sample collected... volume must be 0.003 dscm except that shorter sampling times or smaller volumes, when necessitated by...
The purpose of this SOP is to describe the procedures for storage and shipping of samples. For the NHEXAS project, Harvard School of Public Health/Emory University will collect many different kinds of samples, some of which will require particularly careful storage and shipping ...
This SOP describes the procedures to set up, calibrate, initiate and terminate air sampling for persistent organic pollutants. This method is used to sample air, indoors and outdoors, at homes and at day care centers over a 48-hr period.
40 CFR 60.496 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Surface Coating Industry § 60.496 Test methods and procedures. (a) The reference methods in appendix A to...) Method 4 for stack gas moisture. (b) For Method 24, the coating sample must be a 1-litre sample collected... volume must be 0.003 dscm except that shorter sampling times or smaller volumes, when necessitated by...
Wood, Warren W.
1976-01-01
The unstable nature of many chemical and physical constituents in ground water requires special collection procedures and field analysis immediately after collection. This report describes the techniques and equipment commonly used m the collection and field analysis of samples for pH, temperature, carbonate, bicarbonate, specific conductance, Eh, and dissolved oxygen.
USEPA/USGS Sample Collection Protocol for Bacterial ...
Report/SOP This Sample Collection Procedure (SCP) describes the activities and considerations for the collection of bacterial pathogens from representative surface soil samples (0-5 cm). This sampling depth can be reached without the use of a drill rig, direct-push technology, or other mechanized equipment. Analizing soil samples for biothreat agents may, for instance, define the extent of contamination or determine whether the concentrations of contaminants present a risk to public health, welfare, or the environment.
US EPA BASE Study Standard Operating Procedure for Sampling of Particulates
The objective of the procedure described is to collect a sample of particles of respirable and inhalable size (approx. 0.1 to 10 microns in diameter) from indoor air and from the outdoor air supplied to the indoor space tested.
NHEXAS PHASE I ARIZONA STUDY--LIST OF STANDARD OPERATING PROCEDURES
This document lists available protocols and SOPs for the NHEXAS Phase I Arizona study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis, (3) General laboratory procedures, (4) Quality Assurance, (...
Schmitt, Christopher J.; Blazer, Vicki; Dethloff, Gail M.; Tillitt, Donald E.; Gross, Timothy S.; Bryant, Wade L.; DeWeese, L. Rod; Smith, Stephen B.; Goede, Ronald W.; Bartish, Timothy M.; Kubiak, Timothy J.
1999-01-01
This document describes procedures used to collect information, tissues, and fluids for documenting the exposure of fish to environmental contaminants. For the procedures described here, fish are captured (preferably by electrofishing) and held alive until processing (generally <1 h). Fish are weighed, measured, and examined for grossly visible external lesions and pathologies. A blood sample is collected by caudal veinipuncture using a needle and syringe. The fish is subdued and it's abdominal cavity opened. The internal organs are dissected from the fish for examination. The sex of the fish is determined by direct observation of its gonads. The liver is weighed (most species) and cut into small cubes and flash-frozen in cryogenic vials, which are stored and shipped in dry ice or liquid nitrogen. Additional liver cubes plus all grossly visible anomalies are preserved for histopathology. The gonads and spleen are weighed, and samples are preserved for histopathology. The kidneys are examined, and histopathology samples collected. A gill sample is also collected and preserved. All remaining tissues are returned to the carcass, which is wrapped in foil, labeled for chemical analysis, and chilled. Individual fish carcasses are composited by station, species, and gender; frozen; and shipped to the analytical laboratory. Procedures are also described for record keeping; processing blood to obtain serum and plasma; flash-freezing samples; cleaning equipment; and preventing the transport of living organisms among waterways. A list of necessary equipment and supplies is also provided.
Young, Stacie T.M.; Ball, Marcael T.J.
2005-01-01
Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. This program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream. For this program, rainfall data were collected at two stations, continuous streamflow data at two stations, and water-quality data at five stations, which include the two continuous streamflow stations. This report summarizes rainfall, streamflow, and water-quality data collected between July 1, 2004 and June 30, 2005. A total of 15 samples was collected over three storms during July 1, 2004 to June 30, 2005. In general, an attempt was made to collect grab samples nearly simultaneously at all five stations and flow-weighted time-composite samples at the three stations equipped with automatic samplers. However, all three storms were partially sampled because either not all stations were sampled or not all composite samples were collected. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc). Chromium and nickel were added to the analysis starting October 1, 2004. Grab samples were additionally analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Quality-assurance/quality-control samples were also collected during storms and during routine maintenance to verify analytical procedures and check the effectiveness of equipment-cleaning procedures.
Comparison of mine waste assessment methods at the Rattler mine site, Virginia Canyon, Colorado
Hageman, Phil L.; Smith, Kathleen S.; Wildeman, Thomas R.; Ranville, James F.
2005-01-01
In a joint project, the mine waste-piles at the Rattler Mine near Idaho Springs, Colorado, were sampled and analyzed by scientists from the U.S. Geological Survey (USGS) and the Colorado School of Mines (CSM). Separate sample collection, sample leaching, and leachate analyses were performed by both groups and the results were compared. For the study, both groups used the USGS sampling procedure and the USGS Field Leach Test (FLT). The leachates generated from these tests were analyzed for a suite of elements using ICP-AES (CSM) and ICP-MS (USGS). Leachate geochemical fingerprints produced by the two groups for composites collected from the same mine waste showed good agreement. In another set of tests, CSM collected another set of Rattler mine waste composite samples using the USGS sampling procedure. This set of composite samples was leached using the Colorado Division of Minerals and Geology (CDMG) leach test, and a modified Toxicity Characteristic Leaching Procedure (TCLP) leach test. Leachate geochemical fingerprints produced using these tests showed a variation of more than a factor of two from the geochemical fingerprints produced using the USGS FLT leach test. We have concluded that the variation in the results is due to the different parameters of the leaching tests and not due to the sampling or analytical methods.
Young, Stacie T.M.; Jamison, Marcael T.J.
2007-01-01
Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. This program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream. For this program, rainfall data were collected at two stations, continuous streamflow data at three stations, and water-quality data at five stations, which include the two continuous streamflow stations. This report summarizes rainfall, streamflow, and water-quality data collected between July 1, 2006 and June 30, 2007. A total of 13 samples was collected over two storms during July 1, 2006 to June 30, 2007. The goal was to collect grab samples nearly simultaneously at all five stations and flow-weighted time-composite samples at the three stations equipped with automatic samplers. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc). Additionally, grab samples were analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Quality-assurance/quality-control samples were also collected during storms and during routine maintenance to verify analytical procedures and check the effectiveness of equipment-cleaning procedures.
This compendium contains seven SOPs developed by Food and Drug Administration (FDA) laboratories for methods of analyzing trace metals in dietary samples collected using Total Diet study procedures. The SOPs include the following: (1) Quality Control for Analysis of NHEXAS Food o...
The purpose of this SOP is to describe the collection, storage, and shipment of tap and drinking water samples for analysis by EPA method 524.2 (revision 4.0) for the NHEXAS Arizona project. This SOP provides a brief description of the sample containers, collection, preservation...
Collective Negotiations and Teacher Satisfaction in Selected Indiana Secondary Schools.
ERIC Educational Resources Information Center
Davies, Paul R.; Kline, Charles E.
This paper reports a study that sought to determine whether differences in bargaining procedures are related to differences in teacher satisfaction or morale. Of the forty schools in the random sample, 27 were operating under traditional collective negotiation procedures -- teachers relatively unorganized; eight were operating under procedural…
Evaluation of a standardized micro-vacuum sampling method for collection of surface dust.
Ashley, Kevin; Applegate, Gregory T; Wise, Tamara J; Fernback, Joseph E; Goldcamp, Michael J
2007-03-01
A standardized procedure for collecting dust samples from surfaces using a micro-vacuum sampling technique was evaluated. Experiments were carried out to investigate the collection efficiency of the vacuum sampling method described in ASTM Standard D7144, "Standard Practice for Collection of Surface Dust by Micro-Vacuum Sampling for Subsequent Metals Determination." Weighed masses ( approximately 5, approximately 10 and approximately 25 mg) of three NIST Standard Reference Materials (SRMs) were spiked onto surfaces of various substrates. The SRMs used were: (1) Powdered Lead-Based Paint; (2) Urban Particulate Matter; and (3) Trace Elements in Indoor Dust. Twelve different substrate materials were chosen to be representative of surfaces commonly encountered in occupational and/or indoor settings: (1) wood, (2) tile, (3) linoleum, (4) vinyl, (5) industrial carpet, (6) plush carpet, (7,8) concrete block (painted and unpainted), (9) car seat material, (10) denim, (11) steel, and (12) glass. Samples of SRMs originally spiked onto these surfaces were collected using the standardized micro-vacuum sampling procedure. Gravimetric analysis of material collected within preweighed Accucapinserts (housed within the samplers) was used to measure SRM recoveries. Recoveries ranged from 21.6% (+/- 10.4%, 95% confidence limit [CL]) for SRM 1579 from industrial carpet to 59.2% (+/- 11.0%, 95% CL) for SRM 1579 from glass. For most SRM/substrate combinations, recoveries ranged from approximately 25% to approximately 50%; variabilities differed appreciably. In general, SRM recoveries were higher from smooth and hard surfaces and lower from rough and porous surfaces. Material captured within collection nozzles attached to the sampler inlets was also weighed. A significant fraction of SRM originally spiked onto substrate surfaces was captured within collection nozzles. Percentages of SRMs captured within collection nozzles ranged from approximately 13% (+/- 4 - +/- 5%, 95% CLs) for SRMs 1579 and 2583 from industrial carpet to approximately 45% (+/- 7 - +/- 26%, 95% CLs) for SRM 1648 from glass, tile and steel. For some substrates, loose material from the substrate itself (i.e., substrate particles and fibers) was sometimes collected along with the SRM, both within Accucaps as well as collection nozzles. Co-collection of substrate material can bias results and contribute to sampling variability. The results of this work have provided performance data on the standardized micro-vacuum sampling procedure.
This abstract is included for completeness of documentation, but this SOP was not used in the study.
The purpose of this SOP is to describe the procedures for analyzing both Stage II and Stage III soil and vacuum-cleaner collected house dust samples, and Stage III air samples u...
40 CFR 761.286 - Sample size and procedure for collecting a sample.
Code of Federal Regulations, 2010 CFR
2010-07-01
... On-Site Disposal of Bulk PCB Remediation Waste and Porous Surfaces in Accordance With § 761.61(a)(6... PCB remediation waste or porous surfaces, collect at least 20 milliliters of waste, or a portion of...
Implementation of Wi-Fi Signal Sampling on an Android Smartphone for Indoor Positioning Systems.
Liu, Hung-Huan; Liu, Chun
2017-12-21
Collecting and maintaining radio fingerprint for wireless indoor positioning systems involves considerable time and labor. We have proposed the quick radio fingerprint collection (QRFC) algorithm which employed the built-in accelerometer of Android smartphones to implement step detection in order to assist in collecting radio fingerprints. In the present study, we divided the algorithm into moving sampling (MS) and stepped MS (SMS), and describe the implementation of both algorithms and their comparison. Technical details and common errors concerning the use of Android smartphones to collect Wi-Fi radio beacons were surveyed and discussed. The results of signal sampling experiments performed in a hallway measuring 54 m in length showed that in terms of the amount of time required to complete collection of access point (AP) signals, static sampling (SS; a traditional procedure for collecting Wi-Fi signals) took at least 2 h, whereas MS and SMS took approximately 150 and 300 s, respectively. Notably, AP signals obtained through MS and SMS were comparable to those obtained through SS in terms of the distribution of received signal strength indicator (RSSI) and positioning accuracy. Therefore, MS and SMS are recommended instead of SS as signal sampling procedures for indoor positioning algorithms.
Implementation of Wi-Fi Signal Sampling on an Android Smartphone for Indoor Positioning Systems
Liu, Chun
2017-01-01
Collecting and maintaining radio fingerprint for wireless indoor positioning systems involves considerable time and labor. We have proposed the quick radio fingerprint collection (QRFC) algorithm which employed the built-in accelerometer of Android smartphones to implement step detection in order to assist in collecting radio fingerprints. In the present study, we divided the algorithm into moving sampling (MS) and stepped MS (SMS), and describe the implementation of both algorithms and their comparison. Technical details and common errors concerning the use of Android smartphones to collect Wi-Fi radio beacons were surveyed and discussed. The results of signal sampling experiments performed in a hallway measuring 54 m in length showed that in terms of the amount of time required to complete collection of access point (AP) signals, static sampling (SS; a traditional procedure for collecting Wi-Fi signals) took at least 2 h, whereas MS and SMS took approximately 150 and 300 s, respectively. Notably, AP signals obtained through MS and SMS were comparable to those obtained through SS in terms of the distribution of received signal strength indicator (RSSI) and positioning accuracy. Therefore, MS and SMS are recommended instead of SS as signal sampling procedures for indoor positioning algorithms. PMID:29267234
40 CFR 141.804 - Aircraft water system operations and maintenance plan.
Code of Federal Regulations, 2013 CFR
2013-07-01
... must include the following requirements for procedures for disinfection and flushing of aircraft water system. (i) The air carrier must conduct disinfection and flushing of the aircraft water system in... water procedures; (ii) Sample collection procedures; (iii) Disinfection and flushing procedures; (iv...
The objective of this procedure is to collect representative samples of volatile organic compound (VOC) contaminants present in indoor and outdoor environments using multisorbent samplers, and to subsequently analyze the concentration of VOCs, as selected by EPA.
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--LIST OF STANDARD OPERATING PROCEDURES
This document lists available protocols and SOPs for the U.S.-Mexico Border Program study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis, (3) General laboratory procedures, (4) Quality Assuranc...
Sulej, Anna Maria; Polkowska, Żaneta; Astel, Aleksander; Namieśnik, Jacek
2013-12-15
The purpose of this study is to propose and evaluate new procedures for determination of fuel combustion products, anti-corrosive and de-icing compounds in runoff water samples collected from the airports located in different regions and characterized by different levels of the activity expressed by the number of flights and the number of passengers (per year). The most difficult step in the analytical procedure used for the determination of PAHs, benzotriazoles and glycols is sample preparation stage, due to diverse matrix composition, the possibility of interference associated with the presence of components with similar physicochemical properties. In this study, five different versions of sample preparation using extraction techniques, such as: LLE and SPE, were tested. In all examined runoff water samples collected from the airports, the presence of PAH compounds and glycols was observed. In majority of the samples, BT compounds were determined. Runoff water samples collected from the areas of Polish and British international airports as well as local airports had similar qualitative composition, but quantitative composition of the analytes was very diverse. New and validated analytical methodologies ensure that the necessary information for assessing the negative impact of airport activities on the environment can be obtained. © 2013 Elsevier B.V. All rights reserved.
Cuffney, T.F.; Gurtz, M.E.; Meador, M.R.
1993-01-01
Benthic invertebrate samples are collected as part of the U.S. Geological Survey's National Water-Quality Assessment Program. This is a perennial, multidisciplinary program that integrates biological, physical, and chemical indicators of water quality to evaluate status and trends and to develop an understanding of the factors controlling observed water quality. The Program examines water quality in 60 study units (coupled ground- and surface-water systems) that encompass most of the conterminous United States and parts of Alaska and Hawaii. Study-unit teams collect and process qualitative and semi-quantitative invertebrate samples according to standardized procedures. These samples are processed (elutriated and subsampled) in the field to produce as many as four sample components: large-rare, main-body, elutriate, and split. Each sample component is preserved in 10-percent formalin, and two components, large-rare and main-body, are sent to contract laboratories for further processing. The large-rare component is composed of large invertebrates that are removed from the sample matrix during field processing and placed in one or more containers. The main-body sample component consists of the remaining sample materials (sediment, detritus, and invertebrates) and is subsampled in the field to achieve a volume of 750 milliliters or less. The remaining two sample components, elutriate and split, are used for quality-assurance and quality-control purposes. Contract laboratories are used to identify and quantify invertebrates from the large-rare and main-body sample components according to the procedures and guidelines specified within this document. These guidelines allow the use of subsampling techniques to reduce the volume of sample material processed and to facilitate identifications. These processing procedures and techniques may be modified if the modifications provide equal or greater levels of accuracy and precision. The intent of sample processing is to determine the quantity of each taxon present in the semi-quantitative samples or to list the taxa present in qualitative samples. The processing guidelines provide standardized laboratory forms, sample labels, detailed sample processing flow charts, standardized format for electronic data, quality-assurance procedures and checks, sample tracking standards, and target levels for taxonomic determinations. The contract laboratory (1) is responsible for identifications and quantifications, (2) constructs reference collections, (3) provides data in hard copy and electronic forms, (4) follows specified quality-assurance and quality-control procedures, and (5) returns all processed and unprocessed portions of the samples. The U.S. Geological Survey's Quality Management Group maintains a Biological Quality-Assurance Unit, located at the National Water-Quality Laboratory, Arvada, Colorado, to oversee the use of contract laboratories and ensure the quality of data obtained from these laboratories according to the guidelines established in this document. This unit establishes contract specifications, reviews contractor performance (timeliness, accuracy, and consistency), enters data into the National Water Information System-II data base, maintains in-house reference collections, deposits voucher specimens in outside museums, and interacts with taxonomic experts within and outside the U.S. Geological Survey. This unit also modifies the existing sample processing and quality-assurance guidelines, establishes criteria and testing procedures for qualifying potential contract laboratories, identifies qualified taxonomic experts, and establishes voucher collections.
The purpose of this SOP is to describe the collection, storage, and shipment of tap and drinking water samples for analysis by EPA method 524.2 (revision 4.0). This SOP provides a brief description of the sample containers, collection, preservation, storage, shipping, and custod...
The purpose of this SOP is to describe how to collect, store, and ship tap and drinking water samples for analysis by EPA Method 200.8 (revision 4.4) for the NHEXAS Arizona project. This SOP provides a brief description of the sample containers, collection, preservation, storage...
40 CFR 61.174 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Arsenic Emissions From Primary Copper Smelters § 61.174 Test methods and procedures. (a) To determine... converter arsenic charging rate as follows: (1) Collect daily grab samples of copper matte and any lead... determine the weight percent of inorganic arsenic contained in each sample. (3) Calculate the converter...
The objective of this procedure is to collect a representative sample of air containing volatile organic compound (VOC) contaminants present in an indoor environment using an evacuated canister, and to subsequently analyze the concentration of VOCs, as selected by EPA.
The objective of the procedure is to collect a representative sample concentration of total airborne fungal spores (viable and non-viable) that may be present in indoor air and in the outdoor air supplied to the space tested.
Dumouchelle, D.H.; Lynch, E.A.; Cummings, T.R.
1990-01-01
A survey of literature on well installation and water-quality sampling, particularly as they relate to investigations of ground-water contamination by organic compounds, has been conducted. Library card files and computerized data bases were searched to identify journal articles, conference proceedings, technical reports, books, and other publications. Pertinent information has been extracted from 105 references; each reference is listed in a bibliography. Material contained in the report is organized by topical categories that include drilling methods and equipment, well construction, well development, sampling materials and equipment, decontamination of equipment, and sampling techniques and procedures. Unpublished data of the U.S. Geological Survey on sample collection are briefly cited also.
ERIC Educational Resources Information Center
Taylor, Matthew A.; Skourides, Andreas; Alvero, Alicia M.
2012-01-01
Interval recording procedures are used by persons who collect data through observation to estimate the cumulative occurrence and nonoccurrence of behavior/events. Although interval recording procedures can increase the efficiency of observational data collection, they can also induce error from the observer. In the present study, 50 observers were…
Presley, Todd K.; Jamison, Marcael T.J.; Young-Smith, Stacie T. M.
2006-01-01
Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. This program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream. For this program, rainfall data were collected at two stations, continuous discharge data at one station, continuous streamflow data at two stations, and water-quality data at five stations, which include the continuous discharge and streamflow stations. This report summarizes rainfall, discharge, streamflow, and water-quality data collected between July 1, 2005 and June 30, 2006. A total of 23 samples was collected over five storms during July 1, 2005 to June 30, 2006. The goal was to collect grab samples nearly simultaneously at all five stations, and flow-weighted time-composite samples at the three stations equipped with automatic samplers; however, all five storms were partially sampled owing to lack of flow at the time of sampling at some sites, or because some samples collected by the automatic sampler did not represent water from the storm. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc). Additionally, grab samples were analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Quality-assurance/quality-control samples were also collected during storms and during routine maintenance to verify analytical procedures and check the effectiveness of equipment-cleaning procedures.
,
2015-01-01
The general consideration for implementation of the GCMS is that all active USGS geologic sample repositories will form the core of GCMS and that participating science centers will develop procedures based on proposed GCMS methodologies. The GCMS is a collective resource for the entire USGS community and the users who discover the geologic materials kept in these repositories and seek to access them.
This SOP describes the method for collection of the food preparation surface wipe samples for the measurement of persistent organic pollutants (POP). This method uses a wipe to collect POP residues from a surface where a study participant prepares food the most often (i.e., kitch...
Fisher, Shawn C.; Reilly, Timothy J.; Jones, Daniel K.; Benzel, William M.; Griffin, Dale W.; Loftin, Keith A.; Iwanowicz, Luke R.; Cohl, Jonathan A.
2015-12-17
An understanding of the effects on human and ecological health brought by major coastal storms or flooding events is typically limited because of a lack of regionally consistent baseline and trends data in locations proximal to potential contaminant sources and mitigation activities, sensitive ecosystems, and recreational facilities where exposures are probable. In an attempt to close this gap, the U.S. Geological Survey (USGS) has implemented the Sediment-bound Contaminant Resiliency and Response (SCoRR) strategy pilot study to collect regional sediment-quality data prior to and in response to future coastal storms. The standard operating procedure (SOP) detailed in this document serves as the sample-collection protocol for the SCoRR strategy by providing step-by-step instructions for site preparation, sample collection and processing, and shipping of soil and surficial sediment (for example, bed sediment, marsh sediment, or beach material). The objectives of the SCoRR strategy pilot study are (1) to create a baseline of soil-, sand-, marsh sediment-, and bed-sediment-quality data from sites located in the coastal counties from Maine to Virginia based on their potential risk of being contaminated in the event of a major coastal storm or flooding (defined as Resiliency mode); and (2) respond to major coastal storms and flooding by reoccupying select baseline sites and sampling within days of the event (defined as Response mode). For both modes, samples are collected in a consistent manner to minimize bias and maximize quality control by ensuring that all sampling personnel across the region collect, document, and process soil and sediment samples following the procedures outlined in this SOP. Samples are analyzed using four USGS-developed screening methods—inorganic geochemistry, organic geochemistry, pathogens, and biological assays—which are also outlined in this SOP. Because the SCoRR strategy employs a multi-metric approach for sample analyses, this protocol expands upon and reconciles differences in the sample collection protocols outlined in the USGS “National Field Manual for the Collection of Water-Quality Data,” which should be used in conjunction with this SOP. A new data entry and sample tracking system also is presented to ensure all relevant data and metadata are gathered at the sample locations and in the laboratories.
Long Term Resource Monitoring Program procedures: fish monitoring
Ratcliff, Eric N.; Glittinger, Eric J.; O'Hara, T. Matt; Ickes, Brian S.
2014-01-01
This manual constitutes the second revision of the U.S. Army Corps of Engineers’ Upper Mississippi River Restoration-Environmental Management Program (UMRR-EMP) Long Term Resource Monitoring Program (LTRMP) element Fish Procedures Manual. The original (1988) manual merged and expanded on ideas and recommendations related to Upper Mississippi River fish sampling presented in several early documents. The first revision to the manual was made in 1995 reflecting important protocol changes, such as the adoption of a stratified random sampling design. The 1995 procedures manual has been an important document through the years and has been cited in many reports and scientific manuscripts. The resulting data collected by the LTRMP fish component represent the largest dataset on fish within the Upper Mississippi River System (UMRS) with more than 44,000 collections of approximately 5.7 million fish. The goal of this revision of the procedures manual is to document changes in LTRMP fish sampling procedures since 1995. Refinements to sampling methods become necessary as monitoring programs mature. Possible refinements are identified through field experiences (e.g., sampling techniques and safety protocols), data analysis (e.g., planned and studied gear efficiencies and reallocations of effort), and technological advances (e.g., electronic data entry). Other changes may be required because of financial necessity (i.e., unplanned effort reductions). This version of the LTRMP fish monitoring manual describes the most current (2014) procedures of the LTRMP fish component.
The purpose of this SOP is to describe how to collect, store, and ship tap and drinking water samples for analysis by EPA Method 200.8 (revision 4.4) for the NHEXAS Arizona project. This SOP provides a brief description of the sample containers, collection, preservation, storage...
Kamps, Amanda J; Dubay, Shelli A; Langenberg, Julie; Maes, Roger K
2015-07-01
Blood samples are often collected from free-ranging wildlife for antibody detection. However, filter-paper (FP) strips are more cost efficient and easy to collect and store. We evaluated trapper-collected FP strips and body-cavity blood for canine distemper (CDV) and parvovirus (CPV-2) antibody detection in raccoons (Procyon lotor) and coyotes (Canis latrans). From 2008 to 2010, licensed trappers near Madison and Milwaukee, Wisconsin, US collected paired samples from harvested animals. Canine distemper antibodies were detected using virus neutralization and parvovirus antibodies were detected using hemagglutination inhibition. Titers ≥ 1:32 for CDV and ≥ 1:25 for CPV-2 were considered evidence of exposure. Using Cohen's kappa test of agreement, FP strip titers agreed with sera for CDV in coyotes (n = 28, K = 0.772) and raccoons (n = 29, K = 0.858) and for CPV-2 in coyotes (n = 40, K = 0.775) and raccoons (n = 70, K = 0.646). However, raccoons determined to be exposed to CPV-2 from sera were unexposed by FP strips in 35% of the samples. Titer results may be affected by quality and volume of blood samples, interval between collection and processing, small sample sizes, and diagnostic testing procedures. Filter-paper strips can be useful for detecting CDV and CPV-2 exposure in coyotes and raccoons with correct field sample collection and appropriate diagnostic testing procedures.
Miller, Eleanor I; Murray, Gordon J; Rollins, Douglas E; Tiffany, Stephen T; Wilkins, Diana G
2011-07-01
The aim of this exploratory study was to develop and validate a liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for the quantification of nicotine, eight nicotine metabolites, and two minor tobacco alkaloids in fortified analyte-free hair and subsequently apply this method to hair samples collected from active smokers. An additional aim of the study was to include an evaluation of different wash procedures for the effective removal of environmentally deposited nicotine from tobacco smoke. An apparatus was designed for the purpose of exposing analyte-free hair to environmental tobacco smoke in order to deposit nicotine onto the hair surface. A shampoo/water wash procedure was identified as the most effective means of removing nicotine. This wash procedure was utilized for a comparison of washed and unwashed heavy smoker hair samples. Analytes and corresponding deuterated internal standards were extracted using a cation-exchange solid-phase cartridge. LC-MS-MS was carried out using an Acquity™ UPLC(®) system (Waters) and a Quattro Premier XE™ triple quadrupole MS (Waters) operated in electrospray positive ionization mode, with multiple reaction monitoring data acquisition. The developed method was applied to hair samples collected from heavy smokers (n = 3) and low-level smokers (n = 3) collected through IRB-approved protocols. Nicotine, cotinine, and nornicotine were quantified in both the washed and unwashed hair samples collected from three heavy smokers, whereas 3-hydroxycotinine was quantified in only one unwashed sample and nicotine-1'-oxide in the washed and unwashed hair samples from two heavy smokers. In contrast, nicotine-1'-oxide was quantified in one of the three low-level smoker samples; nicotine was quantified in the other two low-level smoker samples. No other analytes were detected in the hair of the three low-level smokers.
The Quality System Implementation Plan (QSIP) describes the quality assurance and quality control procedures developed for the CTEPP study. It provides the QA/QC procedures used in recruitment of subjects, sample field collection, sample extraction and analysis, data storage, and...
The purpose of this SOP is to indicate the proper method for assigning unique Identification Numbers for all samples taken and forms used in the collection of NHEXAS Pilot Studies. All data tracking procedures were built upon these ID numbers. Inspection of these ID numbers pro...
Deplanque, Dominique; Birraux, Guillaume; Bertoye, Pierre-Henri; Postaire, Eric
2009-01-01
The collection of human biological samples is of major importance for future research in France and Europe. In recent years, new regulatory procedures have been designed to monitor these activities; but they are somewhat complex and some clarifications are needed. The law needs also to be amended. The definition of biobanking activities should be clarified, and regulatory procedures, including consultation of the Ethics Committee, declarations to the Ministry of Research and the protection of personal data, should be simplified. It is also of great importance to correctly define the modalities in which Biobanks are granted their authorisations. The role of Ethics Committees regarding the evaluation of information and the consent procedures should also be clarified, particularly when samples from children are used, or when the samples are used for genetic analyses. As well as scientific and public health aspects, the storage of human biological samples may also have important economic consequences. It is hence crucial to adapt the procedure for submitting patents, particularly when several public or private partners are working together. The possible changes to both French and European laws planned in the next months would be an ideal time to introduce these changes.
Chapter A7. Biological Indicators
Myers, Donna N.; Wilde, Franceska D.
2003-01-01
The National Field Manual for the Collection of Water-Quality Data (National Field Manual) provides guidelines and standard procedures for U.S. Geological Survey (USGS) personnel who collect data used to assess the quality of the Nation's surface-water and ground-water resources. This chapter of the manual includes procedures for the (1) determination of biochemical oxygen demand using a 5-day bioassay test; (2) collection, identification, and enumeration of fecal indicator bacteria; (3) collection of samples and information on two laboratory methods for fecal indicator viruses (coliphages); and (4) collection of samples for protozoan pathogens. Each chapter of the National Field Manual is published separately and revised periodically. Newly published and revised chapters are posted on the World Wide Web on the USGS page 'National Field Manual for the Collection of Water-Quality Data.' The URL for this page is http://pubs.water.usgs.gov/twri9A/ (accessed November 25, 2003).
The purpose of this SOP is to describe how to collect, store, and ship tap and drinking water samples for analysis by EPA Method 525.2 (revision 1.0) and EPA method 531.1 (revision 3). This SOP provides a brief description of the sample containers, collection, preservation, stor...
The purpose of this SOP is to describe collection, storage, and shipment requirements of blood samples for metal, pesticide, polynuclear aromatic hydrocarbons (PAHs), volatile organic compound (VOC), and lipid analysis. Seven samples were taken from a single puncture: two 3-mL t...
ERIC Educational Resources Information Center
Thomson, William A.; And Others
While educational researchers frequently collect data from a sample of individuals on a sample of variables, they sometimes collect data involving samples of: (1) subjects; (2) variables; and (3) occasions of measurement. A multistage procedure for analyzing such three-mode data is presented, focusing on effect sizes and graphic confidence…
New Approaches to Demographic Data Collection
Treiman, Donald J.; Lu, Yao; Qi, Yaqiang
2013-01-01
As population scientists have expanded the range of topics they study, increasingly considering the interrelationship between population phenomena and social, economic, and health conditions, they have expanded the kinds of data collected and have brought to bear new data collection techniques and procedures, often borrowed from other fields. These new approaches to demographic data collection are the concern of this essay. We consider three main topics: new developments in sampling procedures; new developments in fieldwork procedures; and new developments in the kind of information collected in demographic and social surveys. We conclude with some comments on data sharing in the social research community and a list of major Chinese surveys publicly available to researchers. Where possible we illustrate our points with Chinese examples. PMID:23844330
Apollo-11 lunar sample information catalogue
NASA Technical Reports Server (NTRS)
Kramer, F. E. (Compiler); Twedell, D. B. (Compiler); Walton, W. J. A., Jr. (Compiler)
1977-01-01
The Apollo 11 mission is reviewed with emphasis on the collection of lunar samples, their geologic setting, early processing, and preliminary examination. The experience gained during five subsequent missions was applied to obtain physical-chemical data for each sample using photographic and binocular microscope techniques. Topics discussed include: binocular examination procedure; breccia clast dexrriptuons, thin section examinations procedure typical breccia in thin section, typical basalt in thin section, sample histories, and chemical and age data. An index to photographs is included.
ACQUISITION OF REPRESENTATIVE GROUND WATER QUALITY SAMPLES FOR METALS
R.S. Kerr Environmental Research Laboratory (RSKERL) personnel have evaluated sampling procedures for the collection of representative, accurate, and reproducible ground water quality samples for metals for the past four years. Intensive sampling research at three different field...
Audit of lymphadenectomy in lung cancer resections using a specimen collection kit and checklist
Osarogiagbon, Raymond U.; Sareen, Srishti; Eke, Ransome; Yu, Xinhua; McHugh, Laura M.; Kernstine, Kemp H.; Putnam, Joe B.; Robbins, Edward T.
2014-01-01
Background Audits of operative summaries and pathology reports reveal wide discordance in identifying the extent of lymphadenectomy performed (the communication gap). We tested the ability of a pre-labeled lymph node specimen collection kit and checklist to narrow the communication gap between operating surgeons, pathologists, and auditors of surgeons’ operation notes. Methods We conducted a prospective single cohort study of lung cancer resections performed with a lymph node collection kit from November 2010 to January 2013. We used the kappa statistic to compare surgeon claims on a checklist of lymph node stations harvested intraoperatively, to pathology reports, and an independent audit of surgeons’ operative summaries. Lymph node collection procedures were classified into 4 groups based on the anatomic origin of resected lymph nodes: mediastinal lymph node dissection, systematic sampling, random sampling and no sampling. Results From the pathology report, 73% of 160 resections had a mediastinal lymph node dissection or systematic sampling procedure, 27% had random sampling. The concordance with surgeon claims was 80% (kappa statistic 0.69 [CI 0.60 – 0.79]). Concordance between independent audits of the operation notes and either the pathology report (kappa 0.14 [0.04 – 0.23]), or surgeon claims (kappa 0.09 [0.03 – 0.22]), was poor. Conclusion A pre-labeled specimen collection kit and checklist significantly narrowed the communication gap between surgeons and pathologists in identifying the extent of lymphadenectomy. Audit of surgeons’ operation notes did not accurately reflect the procedure performed, bringing its value for quality improvement work into question. PMID:25530090
NASA Astrophysics Data System (ADS)
Chan, Y. C.; Vowles, P. D.; McTainsh, G. H.; Simpson, R. W.; Cohen, D. D.; Bailey, G. M.; McOrist, G. D.
This paper describes a method for the simultaneous collection of size-fractionated aerosol samples on several collection substrates, including glass-fibre filter, carbon tape and silver tape, with a commercially available high-volume cascade impactor. This permitted various chemical analysis procedures, including ion beam analysis (IBA), instrumental neutron activation analysis (INAA), carbon analysis and scanning electron microscopy (SEM), to be carried out on the samples.
Water-quality sampling by the U.S. Geological Survey-Standard protocols and procedures
Wilde, Franceska D.
2010-01-01
Thumbnail of and link to report PDF (1.0 MB) The U.S. Geological Survey (USGS) develops the sampling procedures and collects the data necessary for the accurate assessment and wise management of our Nation's surface-water and groundwater resources. Federal and State agencies, water-resource regulators and managers, and many organizations and interested parties in the public and private sectors depend on the reliability, timeliness, and integrity of the data we collect and the scientific soundness and impartiality of our data assessments and analysis. The standard data-collection methods uniformly used by USGS water-quality personnel are peer reviewed, kept up-to-date, and published in the National Field Manual for the Collection of Water-Quality Data (http://pubs.water.usgs.gov/twri9A/).
Hladik, Michelle; Orlando, James L.; Kuivila, Kathryn
2009-01-01
Loss of pyrethroid insecticides onto surfaces during sample collection can confound the interpretation of analytical and toxicity test results. Sample collection devices, container materials, and water matrix composition have a significant influence on the association of pyrethroids to container walls, which can be as high as 50 percent. Any sample collection method involving transfer through multiple containers or pieces of equipment increases the potential for pyrethroid loss. This loose 'surface-association' with container walls can be reversed through agitation. When sampling water matrices with pumps or autosamplers, no pyrethroids were lost as long as the water was moving continuously through the system. When collecting water matrices in containers, the material with the least amount of pyrethroid sorption is as follows: glass less than (<) plastic less than (<) Teflon. Additionally, pyrethroids were easier to re-suspend from the glass container walls. Since the amount of surface-association is proportional to the ratio of volume-to-contact-area of the sample, taking larger-volume field samples (greater than 3 liters) reduced pyrethroid losses to less than 10 percent. The amount of surface-association cannot be predicted easily because of the dependence on water matrix composition; samples with higher dissolved organic carbon or suspended-sediment concentrations were observed to have lower percent loss. Sediment samples were not affected by glass-container sorption (the only containers tested). Standardized sample-collection protocols are critical to yield accurate pyrethroid concentrations for assessment of potential effects, and have been summarized in an accompanying standard operating procedure.
The purpose of the SOP is to establish the normal procedures for ensuring data chain-of-custody and data tracking. The chain-of-custody form included in this SOP is the standard form to be used for all data collected in the field. Keywords: samples; custody; records.
The Nat...
ERIC Educational Resources Information Center
Becraft, Jessica L.; Borrero, John C.; Davis, Barbara J.; Mendres-Smith, Amber E.
2016-01-01
The current study was designed to evaluate a rotating momentary time sampling (MTS) data collection system. A rotating MTS system has been used to measure activity preferences of preschoolers but not to collect data on responses that vary in duration and frequency (e.g., talking). We collected data on talking for 10 preschoolers using a 5-s MTS…
Jacobsen, Katja Kemp; Brandt, Ida; Christensen, Anne Vindahl; Rimsø, Bjørk Anine; Krøier, Camilla Julie; Sørensen, Michelle; Smith, Julie; Jensen, Kathrine Overgaard Foss; Larsen, Jeppe Madura
2018-06-01
Deviation in blood collection procedures is a central source of preanalytical variation affecting overall analytical and diagnostic precision. The order of draw of venous sampling is suspected to affect analytical results, in particular for coagulation analysis. Here we compare the procedures in venous blood sampling among clinical biochemistry departments to assess the uniformity of order of blood draw and adherence to international guidelines in the Danish health care system. We collected venous order of draw procedures from 49 clinical biochemistry departments at 22 public hospitals in Denmark. Procedures were compared to the international guidelines fromthe Clinical Laboratory Standards Institute (CLSI) and World Health Organization (WHO), and assessed in relation to department ISO 15189:2012 accreditation. We observed seven different order of draw procedures related to citrate, serum, heparin, and EDTA tubes, and the use of discard tubes in relation to coagulation assays. 31 departments (63.3%) were found to adhere to CLSI and WHO guidelines. A majority of departments instructs the use of discard tubes before collection for coagulation assays in citrate tubes (44 departments; 89.8%). The citrate tube was the first sample tube to be drawn for most departments (35 departments; 75.5%); and the preferred order of non-citrate tubes was serum-heparin-EDTA (36 departments; 73.5%). Adherence to the CLSI and WHO guidelines was not associated with department ISO 15189:2012 accreditation (p = .57). Venous order of draw procedures is diverse at Danish clinical biochemistry departments and show moderate adherence to international guidelines. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Van Berkel, Gary J.; Kertesz, Vilmos
2011-08-09
A system and method utilizes an image analysis approach for controlling the collection instrument-to-surface distance in a sampling system for use, for example, with mass spectrometric detection. Such an approach involves the capturing of an image of the collection instrument or the shadow thereof cast across the surface and the utilization of line average brightness (LAB) techniques to determine the actual distance between the collection instrument and the surface. The actual distance is subsequently compared to a target distance for re-optimization, as necessary, of the collection instrument-to-surface during an automated surface sampling operation.
Nevada Applied Ecology Group procedures handbook for environmental transuranics
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, M.G.; Dunaway, P.B.
The activities of the Nevada Applied Ecology Group (NAEG) integrated research studies of environmental plutonium and other transuranics at the Nevada Test Site have required many standardized field and laboratory procedures. These include sampling techniques, collection and preparation, radiochemical and wet chemistry analysis, data bank storage and reporting, and statistical considerations for environmental samples of soil, vegetation, resuspended particles, animals, and others. This document, printed in two volumes, includes most of the Nevada Applied Ecology Group standard procedures, with explanations as to the specific applications involved in the environmental studies. Where there is more than one document concerning a procedure,more » it has been included to indicate special studies or applications perhaps more complex than the routine standard sampling procedures utilized.« less
Nevada Applied Ecology Group procedures handbook for environmental transuranics
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, M.G.; Dunaway, P.B.
The activities of the Nevada Applied Ecology Group (NAEG) integrated research studies of environmental plutonium and other transuranics at the Nevada Test Site have required many standardized field and laboratory procedures. These include sampling techniques, collection and preparation, radiochemical and wet chemistry analysis, data bank storage and reporting, and statistical considerations for environmental samples of soil, vegetation, resuspended particles, animals, and other biological material. This document, printed in two volumes, includes most of the Nevada Applied Ecology Group standard procedures, with explanations as to the specific applications involved in the environmental studies. Where there is more than one document concerningmore » a procedure, it has been included to indicate special studies or applications more complex than the routine standard sampling procedures utilized.« less
NASA Technical Reports Server (NTRS)
Brand, R. R.; Barker, J. L.
1983-01-01
A multistage sampling procedure using image processing, geographical information systems, and analytical photogrammetry is presented which can be used to guide the collection of representative, high-resolution spectra and discrete reflectance targets for future satellite sensors. The procedure is general and can be adapted to characterize areas as small as minor watersheds and as large as multistate regions. Beginning with a user-determined study area, successive reductions in size and spectral variation are performed using image analysis techniques on data from the Multispectral Scanner, orbital and simulated Thematic Mapper, low altitude photography synchronized with the simulator, and associated digital data. An integrated image-based geographical information system supports processing requirements.
Methods for collection and analysis of water samples
Rainwater, Frank Hays; Thatcher, Leland Lincoln
1960-01-01
This manual contains methods used by the U.S. Geological Survey to collect, preserve, and analyze water samples. Throughout, the emphasis is on obtaining analytical results that accurately describe the chemical composition of the water in situ. Among the topics discussed are selection of sampling sites, frequency of sampling, field equipment, preservatives and fixatives, analytical techniques of water analysis, and instruments. Seventy-seven laboratory and field procedures are given for determining fifty-three water properties.
Starliper, C.E.
2008-01-01
Refugia are increasingly being used to maintain and propagate imperiled freshwater mussels for future population augmentations. Success for this endeavor is dependent on good husbandry, including a holistic program of resource health management. A significant aspect to optimal health is the prevention or control of infectious diseases. Describing and monitoring pathogens and diseases in mussels involves examination of tissues or samples collected from an appropriate number of individuals that satisfies a certain confidence level for expected prevalences of infections. In the present study, ebonyshell mussels Fusconaia ebena were infected with a fish pathogenic bacterium, Aeromonas salmonicida, through their cohabitation with diseased brook trout Salvelinus fontinalis. At a 100% prevalence of infection, the F. ebena were removed from the cohabitation tank to clean tanks that were supplied with pathogen-free water, which initiated their depuration of A. salmonicida. Three samples (nondestructive fluid, mantle, hemolymph) collected using nondestructive procedures were compared with fluids and soft tissue homogenates collected after sacrificing the mussels for recovery of the bacterium during this period of depuration. Nondestructive sample collections, especially ND fluid, provide a comparable alternative to sacrificing mussels to determine pathogen status.
40 CFR 761.250 - Sample site selection for pipeline section abandonment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Sample site selection for pipeline... Disposal of Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.250 Sample site selection for pipeline section abandonment. This procedure...
40 CFR 761.250 - Sample site selection for pipeline section abandonment.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Sample site selection for pipeline... Disposal of Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.250 Sample site selection for pipeline section abandonment. This procedure...
Lombardi, Giovanni; Sansoni, Veronica; Banfi, Giuseppe
2017-08-01
In the last few years, a growing number of molecules have been associated to an endocrine function of the skeletal muscle. Circulating myokine levels, in turn, have been associated with several pathophysiological conditions including the cardiovascular ones. However, data from different studies are often not completely comparable or even discordant. This would be due, at least in part, to the whole set of situations related to the preparation of the patient prior to blood sampling, blood sampling procedure, processing and/or store. This entire process constitutes the pre-analytical phase. The importance of the pre-analytical phase is often not considered. However, in routine diagnostics, the 70% of the errors are in this phase. Moreover, errors during the pre-analytical phase are carried over in the analytical phase and affects the final output. In research, for example, when samples are collected over a long time and by different laboratories, a standardized procedure for sample collecting and the correct procedure for sample storage are acknowledged. In this review, we discuss the pre-analytical variables potentially affecting the measurement of myokines with cardiovascular functions.
40 CFR 1065.805 - Sampling system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Sampling system. 1065.805 Section 1065... ENGINE-TESTING PROCEDURES Testing With Oxygenated Fuels § 1065.805 Sampling system. (a) Dilute engine exhaust, and use batch sampling to collect proportional flow-weighted dilute samples of the applicable...
40 CFR 1065.805 - Sampling system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Sampling system. 1065.805 Section 1065... ENGINE-TESTING PROCEDURES Testing With Oxygenated Fuels § 1065.805 Sampling system. (a) Dilute engine exhaust, and use batch sampling to collect proportional flow-weighted dilute samples of the applicable...
Stardust Sample: Investigator's Guidebook
NASA Technical Reports Server (NTRS)
Allen, Carl
2006-01-01
In January 2006, the Stardust spacecraft returned the first in situ collection of samples from a comet, and the first samples of contemporary interstellar dust. Stardust is the first US sample return mission from a planetary body since Apollo, and the first ever from beyond the moon. This handbook is a basic reference source for allocation procedures and policies for Stardust samples. These samples consist of particles and particle residues in aerogel collectors, in aluminum foil, and in spacecraft components. Contamination control samples and unflown collection media are also available for allocation.
Johnson, Steven M.; Swanson, Robert B.
1994-01-01
Prototype stream-monitoring sites were operated during part of 1992 in the Central Nebraska Basins (CNBR) and three other study areas of the National Water-Quality Assessment (NAWQ) Program of the U.S. Geological Survey. Results from the prototype project provide information needed to operate a net- work of intensive fixed station stream-monitoring sites. This report evaluates operating procedures for two NAWQA prototype sites at Maple Creek near Nickerson and the Platte River at Louisville, eastern Nebraska. Each site was sampled intensively in the spring and late summer 1992, with less intensive sampling in midsummer. In addition, multiple samples were collected during two high- flow periods at the Maple Creek site--one early and the other late in the growing season. Water-samples analyses included determination of pesticides, nutrients, major ions, suspended sediment, and measurements of physical properties. Equipment and protocols for the water-quality sampling procedures were evaluated. Operation of the prototype stream- monitoring sites included development and comparison of onsite and laboratory sample-processing proce- dures. Onsite processing was labor intensive but allowed for immediate preservation of all sampled constituents. Laboratory processing required less field labor and decreased the risk of contamination, but allowed for no immediate preservation of the samples.
14CO2 analysis of soil gas: Evaluation of sample size limits and sampling devices
NASA Astrophysics Data System (ADS)
Wotte, Anja; Wischhöfer, Philipp; Wacker, Lukas; Rethemeyer, Janet
2017-12-01
Radiocarbon (14C) analysis of CO2 respired from soils or sediments is a valuable tool to identify different carbon sources. The collection and processing of the CO2, however, is challenging and prone to contamination. We thus continuously improve our handling procedures and present a refined method for the collection of even small amounts of CO2 in molecular sieve cartridges (MSCs) for accelerator mass spectrometry 14C analysis. Using a modified vacuum rig and an improved desorption procedure, we were able to increase the CO2 recovery from the MSC (95%) as well as the sample throughput compared to our previous study. By processing series of different sample size, we show that our MSCs can be used for CO2 samples of as small as 50 μg C. The contamination by exogenous carbon determined in these laboratory tests, was less than 2.0 μg C from fossil and less than 3.0 μg C from modern sources. Additionally, we tested two sampling devices for the collection of CO2 samples released from soils or sediments, including a respiration chamber and a depth sampler, which are connected to the MSC. We obtained a very promising, low process blank for the entire CO2 sampling and purification procedure of ∼0.004 F14C (equal to 44,000 yrs BP) and ∼0.003 F14C (equal to 47,000 yrs BP). In contrast to previous studies, we observed no isotopic fractionation towards lighter δ13C values during the passive sampling with the depth samplers.
Collecting, preparing, crossdating, and measuring tree increment cores
Phipps, R.L.
1985-01-01
Techniques for collecting and handling increment tree cores are described. Procedures include those for cleaning and caring for increment borers, extracting the sample from a tree, core surfacing, crossdating, and measuring. (USGS)
Water quality data for selected wells in the Coastal Plain of New Jersey, 1996-98
Hibbs, Kathleen L.; Stackelberg, Paul E.; Kauffman, Leon J.; Ayers, Mark A.
2001-01-01
Water-quality data were collected during 1996-98 for 217 wells in New Jersey and 3 wells in New York as part of the U. S. Geological Survey's National Water Quality Assessment Program. Samples were collected for five ground-water surveys that were designed to assess water quality in major aquifer systems, with an emphasis on recently recharged (shallow) ground water associated with present and recent human activities. This report (1) summarizes the hydrogeologic framework in the areas of data collection; (2) describes the objectives and procedures for designing each ground-water survey; (3) summarizes the procedures and protocols for data collec-tion, analysis, and quality control; and (4) lists the concentrations of inorganic constituents, volatile organic compounds, pesticides, nutrients, and trace elements present in the ground-water samples.
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2006-01-01
The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's LabMaster data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality-control samples analyzed from July 1999 through June 2001. Results for the quality-control samples for 18 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, total aluminum, calcium, chloride and nitrate (ion chromatography and colormetric method) and sulfate. The total aluminum and dissolved organic carbon procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits. The calcium and specific conductance procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The magnesium procedure was biased for the high-concentration and low concentration samples, but was within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 14 of 15 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 17 of the 18 analytes. At least 90 percent of the samples met data-quality objectives for all analytes except ammonium (81 percent of samples met objectives), chloride (75 percent of samples met objectives), and sodium (86 percent of samples met objectives). Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality over the time period, with most ratings for each sample in the good to excellent range. The P-sample (low-ionic-strength constituents) analysis had one satisfactory rating for the specific conductance procedure in one study. The T-sample (trace constituents) analysis had one satisfactory rating for the aluminum procedure in one study and one unsatisfactory rating for the sodium procedure in another. The remainder of the samples had good or excellent ratings for each study. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 89 percent of the samples met data-quality objectives for 10 of the 14 analytes; the exceptions were ammonium, total aluminum, dissolved organic carbon, and sodium. Results indicate a positive bias for the ammonium procedure in all studies. Data-quality objectives were not met in 50 percent of samples analyzed for total aluminum, 38 percent of samples analyzed for dissolved organic carbon, and 27 percent of samples analyzed for sodium. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 91 percent of the samples analyzed for calcium, chloride, fluoride, magnesium, pH, potassium, and sulfate. Data-quality objectives were met by 75 percent of the samples analyzed for sodium and 58 percent of the samples analyzed for specific conductance.
Audit of lymphadenectomy in lung cancer resections using a specimen collection kit and checklist.
Osarogiagbon, Raymond U; Sareen, Srishti; Eke, Ransome; Yu, Xinhua; McHugh, Laura M; Kernstine, Kemp H; Putnam, Joe B; Robbins, Edward T
2015-02-01
Audits of operative summaries and pathology reports reveal wide discordance in identifying the extent of lymphadenectomy performed (the communication gap). We tested the ability of a prelabeled lymph node specimen collection kit and checklist to narrow the communication gap between operating surgeons, pathologists, and auditors of surgeons' operation notes. We conducted a prospective single cohort study of lung cancer resections performed with a lymph node collection kit from November 2010 to January 2013. We used the kappa statistic to compare surgeon claims on a checklist of lymph node stations harvested intraoperatively with pathology reports and an independent audit of surgeons' operative summaries. Lymph node collection procedures were classified into four groups based on the anatomic origin of resected lymph nodes: mediastinal lymph node dissection, systematic sampling, random sampling, and no sampling. From the pathology reports, 73% of 160 resections had a mediastinal lymph node dissection or systematic sampling procedure, 27% had random sampling. The concordance with surgeon claims was 80% (kappa statistic 0.69, 95% confidence interval: 0.60 to 0.79). Concordance between independent audits of the operation notes and either the pathology report (kappa 0.14, 95% confidence interval: 0.04 to 0.23) or surgeon claims (kappa 0.09, 95% confidence interval: 0.03 to 0.22) was poor. A prelabeled specimen collection kit and checklist significantly narrowed the communication gap between surgeons and pathologists in identifying the extent of lymphadenectomy. Audit of surgeons' operation notes did not accurately reflect the procedure performed, bringing its value for quality improvement work into question. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., and identification of Salmonella from environmental samples, cloacal swabs, chick box papers, and... identification of Salmonella from environmental samples, cloacal swabs, chick box papers, and meconium samples... chickens, waterfowl, exhibition poultry, and game birds. All samples and swabs described in this paragraph...
Code of Federal Regulations, 2012 CFR
2012-01-01
..., and identification of Salmonella from environmental samples, cloacal swabs, chick box papers, and... identification of Salmonella from environmental samples, cloacal swabs, chick box papers, and meconium samples... chickens, waterfowl, exhibition poultry, and game birds. All samples and swabs described in this paragraph...
Code of Federal Regulations, 2013 CFR
2013-01-01
..., and identification of Salmonella from environmental samples, cloacal swabs, chick box papers, and... identification of Salmonella from environmental samples, cloacal swabs, chick box papers, and meconium samples... chickens, waterfowl, exhibition poultry, and game birds. All samples and swabs described in this paragraph...
Code of Federal Regulations, 2014 CFR
2014-01-01
..., and identification of Salmonella from environmental samples, cloacal swabs, chick box papers, and... identification of Salmonella from environmental samples, cloacal swabs, chick box papers, and meconium samples... chickens, waterfowl, exhibition poultry, and game birds. All samples and swabs described in this paragraph...
Code of Federal Regulations, 2010 CFR
2010-01-01
..., and identification of Salmonella from environmental samples, cloacal swabs, chick box papers, and... identification of Salmonella from environmental samples, cloacal swabs, chick box papers, and meconium samples... chickens, waterfowl, exhibition poultry, and game birds. All samples and swabs described in this paragraph...
As the Human Exposure Program focuses on the exposure of children to pesticides, there are concerns about the effect, or perceived effect, of components of the sampling procedure on the health and well-being of the infant and the ability to collect pesticide residues.
One...
Rating effectiveness of herbicides in desiccating woody vegetation
Jay R. Bentley; Charles A. Graham
1976-01-01
When the effectiveness of herbicide desiccants for killing and drying woody vegetation on many small test plots is rated, the standard procedures for collecting fuel moisture samples are time consuming and costly. Also, the field data often must be recorded when weather is not suitable for collecting moisture content samples. To overcome these limitations, a new...
40 CFR 63.694 - Testing methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... determine treatment process required HAP biodegradation efficiency (Rbio) for compliance with standards... procedures to minimize the loss of compounds due to volatilization, biodegradation, reaction, or sorption... compounds due to volatilization, biodegradation, reaction, or sorption during the sample collection, storage...
40 CFR 63.694 - Testing methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... determine treatment process required HAP biodegradation efficiency (Rbio) for compliance with standards... procedures to minimize the loss of compounds due to volatilization, biodegradation, reaction, or sorption... compounds due to volatilization, biodegradation, reaction, or sorption during the sample collection, storage...
40 CFR 63.694 - Testing methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... determine treatment process required HAP biodegradation efficiency (Rbio) for compliance with standards... procedures to minimize the loss of compounds due to volatilization, biodegradation, reaction, or sorption... compounds due to volatilization, biodegradation, reaction, or sorption during the sample collection, storage...
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2009-01-01
The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's Lab Master data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality control samples analyzed from July 2001 through June 2003. Results for the quality-control samples for 19 analytical procedures were evaluated for bias and precision. Control charts indicate that data for six of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, chloride, magnesium, nitrate (ion chromatography), potassium, and sodium. The calcium procedure was biased throughout the analysis period for the high-concentration sample, but was within control limits. The total monomeric aluminum and fluoride procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The total aluminum, pH, specific conductance, and sulfate procedures were biased for the high-concentration and low-concentration samples, but were within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 16 of 18 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for the dissolved organic carbon or specific conductance procedures. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 18 of the 21 analytes. At least 90 percent of the samples met data-quality objectives for all procedures except total monomeric aluminum (83 percent of samples met objectives), total aluminum (76 percent of samples met objectives), ammonium (73 percent of samples met objectives), dissolved organic carbon (86 percent of samples met objectives), and nitrate (81 percent of samples met objectives). The data-quality objective was not met for the nitrite procedure. Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated satisfactory or above data quality over the time period, with most performance ratings for each sample in the good-to-excellent range. The N-sample (nutrient constituents) analysis had one unsatisfactory rating for the ammonium procedure in one study. The T-sample (trace constituents) analysis had one unsatisfactory rating for the magnesium procedure and one marginal rating for the potassium procedure in one study and one unsatisfactory rating for the sodium procedure in another. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 90 percent of the samples met data-quality objectives for 10 of the 14 analytes; the exceptions were acid-neutralizing capacity, ammonium, dissolved organic carbon, and sodium. Data-quality objectives were not met in 37 percent of samples analyzed for acid-neutralizing capacity, 28 percent of samples analyzed for dissolved organic carbon, and 30 percent of samples analyzed for sodium. Results indicate a positive bias for the ammonium procedure in one study and a negative bias in another. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 90 percent of the samples analyzed for calcium, chloride, magnesium, pH, potassium, and sodium. Data-quality objectives were met by 78 percent of
CTEPP STANDARD OPERATING PROCEDURE FOR HANDLING MISSING SAMPLES AND DATA (SOP-2.24)
This SOP describes the method for handling missing samples or data. Missing samples or data will be identified as soon as possible during field sampling. It provides guidance to collect the missing sample or data and document the reason for the missing sample or data.
Investigations at Pinal Creek, Arizona, evaluated routine sampling procedures for determination of aqueous inorganic geochemistry and assessment of contaminant transport by colloidal mobility. Sampling variables included pump type and flow rate, collection under air or nitrogen,...
Shen, Si; Shen, Junwei; Zhu, Liang; Wu, Chaoqun; Li, Dongliang; Yu, Hongyu; Qiu, Yuanyuan; Zhou, Yi
2015-11-01
To establish and manage of multicentral collection bio-sample banks of malignant tumors from digestive system, the paper designed a multicentral management system, established the standard operation procedures (SOPs) and leaded ten hospitals nationwide to collect tumor samples. The biobank has been established for half a year, and has collected 695 samples from patients with digestive system malignant tumor. The clinical data is full and complete, labeled in a unified way and classified to be managed. The clinical and molecular biology researches were based on the biobank, and obtained achievements. The biobank provides a research platform for malignant tumor of digestive system from different regions and of different types.
40 CFR 761.240 - Scope and definitions.
Code of Federal Regulations, 2014 CFR
2014-07-01
...: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.240 Scope and definitions. (a) Use these procedures to select surface sampling sites for natural gas pipe to determine its PCB surface concentration for abandonment-in-place or removal and disposal off-site in...
40 CFR 761.240 - Scope and definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
...: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.240 Scope and definitions. (a) Use these procedures to select surface sampling sites for natural gas pipe to determine its PCB surface concentration for abandonment-in-place or removal and disposal off-site in...
40 CFR 761.240 - Scope and definitions.
Code of Federal Regulations, 2012 CFR
2012-07-01
...: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.240 Scope and definitions. (a) Use these procedures to select surface sampling sites for natural gas pipe to determine its PCB surface concentration for abandonment-in-place or removal and disposal off-site in...
40 CFR 761.240 - Scope and definitions.
Code of Federal Regulations, 2013 CFR
2013-07-01
...: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.240 Scope and definitions. (a) Use these procedures to select surface sampling sites for natural gas pipe to determine its PCB surface concentration for abandonment-in-place or removal and disposal off-site in...
Field Sampling Plan/Quality Assurance Project Plan Volume I of III
This document contains procedures related to the collection and analysis of soil, sediment, groundwater, surface water, air and biota samples at GE’s Pittsfield, Massachusetts facility and at other areas.
Solid sorbent air sampling and analytical procedure for methyl-, dimethyl-, ethyl-, and diethylamine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elskamp, C.J.; Schultz, G.R.
1986-01-01
A sampling and analytical procedure for methyl-, dimethyl-, ethyl-, and diethylamine was developed in order to avoid problems typically encountered in the sampling and analysis of low molecular weight aliphatic amines. Samples are collected with adsorbent tubes containing Amberlite XAD-7 resin coated with the derivatizing reagent, NBD chloride (7-chloro-4-nitrobenzo-2-oxa-1,3-diazole). Analysis is performed by high performance liquid chromatography with the use of a fluorescence and/or UV/visible detector. All four amines can be monitored simultaneously, and neither collection nor storage is affected by humidity. Samples are stable at room temperature for at least two weeks. The methodology has been tested for eachmore » of the four amines at sample loadings equivalent to air concentration ranges of 0.5 to 30 ppm for a sample volume of 10 liters. The method shows promise for determining other airborne primary and secondary low molecular weight aliphatic amines.« less
Katzka, David A; Geno, Debra M; Ravi, Anupama; Smyrk, Thomas C; Lao-Sirieix, Pierre; Miremadi, Ahmed; Miramedi, Ahmed; Debiram, Irene; O'Donovan, Maria; Kita, Hirohito; Kephart, Gail M; Kryzer, Lori A; Camilleri, Michael; Alexander, Jeffrey A; Fitzgerald, Rebecca C
2015-01-01
Management of eosinophilic esophagitis (EoE) requires repeated endoscopic collection of mucosal samples to assess disease activity and response to therapy. An easier and less expensive means of monitoring of EoE is required. We compared the accuracy, safety, and tolerability of sample collection via Cytosponge (an ingestible gelatin capsule comprising compressed mesh attached to a string) with those of endoscopy for assessment of EoE. Esophageal tissues were collected from 20 patients with EoE (all with dysphagia, 15 with stricture, 13 with active EoE) via Cytosponge and then by endoscopy. Number of eosinophils/high-power field and levels of eosinophil-derived neurotoxin were determined; hematoxylin-eosin staining was performed. We compared the adequacy, diagnostic accuracy, safety, and patient preference for sample collection via Cytosponge vs endoscopy procedures. All 20 samples collected by Cytosponge were adequate for analysis. By using a cutoff value of 15 eosinophils/high power field, analysis of samples collected by Cytosponge identified 11 of the 13 individuals with active EoE (83%); additional features such as abscesses were also identified. Numbers of eosinophils in samples collected by Cytosponge correlated with those in samples collected by endoscopy (r = 0.50, P = .025). Analysis of tissues collected by Cytosponge identified 4 of the 7 patients without active EoE (57% specificity), as well as 3 cases of active EoE not identified by analysis of endoscopy samples. Including information on level of eosinophil-derived neurotoxin did not increase the accuracy of diagnosis. No complications occurred during the Cytosponge procedure, which was preferred by all patients, compared with endoscopy. In a feasibility study, the Cytosponge is a safe and well-tolerated method for collecting near mucosal specimens. Analysis of numbers of eosinophils/high-power field identified patients with active EoE with 83% sensitivity. Larger studies are needed to establish the efficacy and safety of this method of esophageal tissue collection. ClinicalTrials.gov number: NCT01585103. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.
Methods and Procedures in PIRLS 2016
ERIC Educational Resources Information Center
Martin, Michael O., Ed.; Mullis, Ina V. S., Ed.; Hooper, Martin, Ed.
2017-01-01
"Methods and Procedures in PIRLS 2016" documents the development of the Progress in International Reading Literacy Study (PIRLS) assessments and questionnaires and describes the methods used in sampling, translation verification, data collection, database construction, and the construction of the achievement and context questionnaire…
Johnson, Clifford L; Dohrmann, Sylvia M; Kerckove, Van de; Diallo, Mamadou S; Clark, Jason; Mohadjer, Leyla K; Burt, Vicki L
2014-11-01
The National Health and Nutrition Examination Survey's (NHANES) National Youth Fitness Survey (NNYFS) was conducted in 2012 by the Centers for Disease Control and Prevention's National Center for Health Statistics (NCHS). NNYFS collected data on physical activity and fitness levels to evaluate the health and fitness of children aged 3-15 in the United States. The survey comprised three levels of data collection: a household screening interview (or screener), an in-home personal interview, and a physical examination. The screener's primary objective was to determine whether any children in the household were eligible for the interview and examination. Eligibility was determined by preset selection probabilities for desired sex-age subdomains. After selection, the in-home personal interview collected demographic, health, physical activity, and nutrition information about the child as well as information about the household. The examination included physical measurements and fitness tests. This report provides background on the NNYFS program and summarizes the survey's sample design specifications. The report presents NNYFS estimation procedures, including the methods used to calculate survey weights for the full sample as well as a combined NHANES/NNYFS sample for 2012 (accessible only through the NCHS Research Data Center). The report also describes appropriate variance estimation methods. Documentation of the sample selection methods, survey content, data collection procedures, and methods to assess nonsampling errors are reported elsewhere. All material appearing in this report is in the public domain and may be reproduced or copied without permission; citation as to source, however, is appreciated.
CTEPP STANDARD OPERATING PROCEDURE FOR SETTING UP A HOUSEHOLD SAMPLING SCHEDULE (SOP-2.10)
This SOP describes the method for scheduling study subjects for field sampling activities in North Carolina (NC) and Ohio (OH). There are three field sampling teams with two staff members on each team. Two field sampling teams collect the field data simultaneously. A third fiel...
Van Berkel, Gary J [Clinton, TN; Kertesz, Vilmos [Knoxville, TN
2012-02-21
A system and method utilizes distance-measuring equipment including a laser sensor for controlling the collection instrument-to-surface distance during a sample collection process for use, for example, with mass spectrometric detection. The laser sensor is arranged in a fixed positional relationship with the collection instrument, and a signal is generated by way of the laser sensor which corresponds to the actual distance between the laser sensor and the surface. The actual distance between the laser sensor and the surface is compared to a target distance between the laser sensor and the surface when the collection instrument is arranged at a desired distance from the surface for sample collecting purposes, and adjustments are made, if necessary, so that the actual distance approaches the target distance.
Pre-analytical issues in the haemostasis laboratory: guidance for the clinical laboratories.
Magnette, A; Chatelain, M; Chatelain, B; Ten Cate, H; Mullier, F
2016-01-01
Ensuring quality has become a daily requirement in laboratories. In haemostasis, even more than in other disciplines of biology, quality is determined by a pre-analytical step that encompasses all procedures, starting with the formulation of the medical question, and includes patient preparation, sample collection, handling, transportation, processing, and storage until time of analysis. This step, based on a variety of manual activities, is the most vulnerable part of the total testing process and is a major component of the reliability and validity of results in haemostasis and constitutes the most important source of erroneous or un-interpretable results. Pre-analytical errors may occur throughout the testing process and arise from unsuitable, inappropriate or wrongly handled procedures. Problems may arise during the collection of blood specimens such as misidentification of the sample, use of inadequate devices or needles, incorrect order of draw, prolonged tourniquet placing, unsuccessful attempts to locate the vein, incorrect use of additive tubes, collection of unsuitable samples for quality or quantity, inappropriate mixing of a sample, etc. Some factors can alter the result of a sample constituent after collection during transportation, preparation and storage. Laboratory errors can often have serious adverse consequences. Lack of standardized procedures for sample collection accounts for most of the errors encountered within the total testing process. They can also have clinical consequences as well as a significant impact on patient care, especially those related to specialized tests as these are often considered as "diagnostic". Controlling pre-analytical variables is critical since this has a direct influence on the quality of results and on their clinical reliability. The accurate standardization of the pre-analytical phase is of pivotal importance for achieving reliable results of coagulation tests and should reduce the side effects of the influence factors. This review is a summary of the most important recommendations regarding the importance of pre-analytical factors for coagulation testing and should be a tool to increase awareness about the importance of pre-analytical factors for coagulation testing.
Measuring fuel moisture content in Alaska: standard methods and procedures.
Rodney A. Norum; Melanie Miller
1984-01-01
Methods and procedures are given for collecting and processing living and dead plant materials for the purpose of determining their water content. Wild-land fuels in Alaska are emphasized, but the methodology is applicable elsewhere. Guides are given for determining the number of samples needed to attain a chosen precision. Detailed procedures are presented for...
Residents Living in Residential Care Facilities: United States, 2010
... NSRCF used a stratified two-stage probability sample design. The first stage was the selection of RCFs ... was 99%. A detailed description of NSRCF sampling design, data collection, and procedures is provided both in ...
78 FR 47329 - Agency Information Collection Activities: Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-05
... planning communities, plans, protocols, and procedures to manage a catastrophic event. The RCPGP is... collection. FEMA Forms: FEMA Form 089-19, RCPGP Investment Justification Template; FEMA Form 089-26, RCGCP (Sample) Detailed Project Plan Template; FEMA Form 089-17, RCPT Membership List. Abstract: The RCPGP is an...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Puls, R.W.; Powell, R.M.
R.S. Kerr Environmental Research Laboratory (RSKERL) personnel have evaluated sampling procedures for the collection of representative, accurate, and reproducible ground water quality samples for metals for the past four years. Intensive sampling research at three different field sites has shown that the method by which samples are collected has a greater impact on sample quality, accuracy, and reproducibility than whether the samples are filtered or not. In particular, sample collection practices that induce artifically high levels of turbidity have been shown to have the greatest negative impacts on sample quality. Results indicated the ineffectiveness of bailer for collection of representativemore » metal samples. Inconsistent operator usage together with excessive purging generally resulted in excessive turbidity and large differences in filtered and unfiltered metal samples. The use of low flow rate purging and sampling consistently produced filtered and unfiltered samples that showed no significant differences in concentrations. Turbidity levels were generally less than 5 NTUs, even in fine-textured glacial till. The authors recommend the use of low flow rates, during both purging and sampling.« less
NASA Astrophysics Data System (ADS)
de Andrade, Jailson B.; Tanner, Roger L.
A method is described for the specific collection of formaldehyde as hydroxymethanesulfonate on bisulfate-coated cellulose filters. Following extraction in aqueous acid and removal on unreacted bisulfite, the hydroxymethanesulfonate is decomposed by base, and HCHO is determined by DNPH (2,4-dinitrophenylhydrazine) derivatization and HPLC. Since the collection efficiency for formaldehyde is moderately high even when sampling ambient air at high-volume flow rates, a limit of detection of 0.2 ppbv is achieved with 30 min sampling times. Interference from acetaldehyde co-collected as 1-hydroxyethanesulfonate is <5% using this procedure. The technique shows promise for both short-term airborne sampling, and as a means of collecting mg-sized samples of HCHO on an inorganic matrix for carbon isotopic analyses.
Blood Sampling in Newborns: A Systematic Review of YouTube Videos.
Bueno, Mariana; Nishi, Érika Tihemi; Costa, Taine; Freire, Laís Machado; Harrison, Denise
Objective of this study was to conduct a systematic review of YouTube videos showing neonatal blood sampling, and to evaluate pain management and comforting interventions used. Selected videos were consumer- or professional-produced videos showing human newborns undergoing heel lancing or venipuncture for blood sampling, videos showing the entire blood sampling procedure (from the first attempt or puncture to the time of application of a cotton ball or bandage), publication date prior to October 2014, Portuguese titles, available audio. Search terms included "neonate," "newborn," "neonatal screening," and "blood collection." Two reviewers independently screened the videos and extracted the following data. A total of 13 140 videos were retrieved, of which 1354 were further evaluated, and 68 were included. Videos were mostly consumer produced (97%). Heel lancing was performed in 62 (91%). Forty-nine infants (72%) were held by an adult during the procedure. Median pain score immediately after puncture was 4 (interquartile range [IQR] = 0-5), and median length of cry throughout the procedure was 61 seconds (IQR = 88). Breastfeeding (3%) and swaddling (1.5%) were rarely implemented. Posted YouTube videos in Portuguese of newborns undergoing blood collection demonstrate minimal use of pain treatment, and maximal distress during procedures. Knowledge translation strategies are needed to implement effective measures for neonatal pain relief and comfort.
Hand held data collection and monitoring system for nuclear facilities
Brayton, D.D.; Scharold, P.G.; Thornton, M.W.; Marquez, D.L.
1999-01-26
Apparatus and method is disclosed for a data collection and monitoring system that utilizes a pen based hand held computer unit which has contained therein interaction software that allows the user to review maintenance procedures, collect data, compare data with historical trends and safety limits, and input new information at various collection sites. The system has a means to allow automatic transfer of the collected data to a main computer data base for further review, reporting, and distribution purposes and uploading updated collection and maintenance procedures. The hand held computer has a running to-do list so sample collection and other general tasks, such as housekeeping are automatically scheduled for timely completion. A done list helps users to keep track of all completed tasks. The built-in check list assures that work process will meet the applicable processes and procedures. Users can hand write comments or drawings with an electronic pen that allows the users to directly interface information on the screen. 15 figs.
Hand held data collection and monitoring system for nuclear facilities
Brayton, Darryl D.; Scharold, Paul G.; Thornton, Michael W.; Marquez, Diana L.
1999-01-01
Apparatus and method is disclosed for a data collection and monitoring system that utilizes a pen based hand held computer unit which has contained therein interaction software that allows the user to review maintenance procedures, collect data, compare data with historical trends and safety limits, and input new information at various collection sites. The system has a means to allow automatic transfer of the collected data to a main computer data base for further review, reporting, and distribution purposes and uploading updated collection and maintenance procedures. The hand held computer has a running to-do list so sample collection and other general tasks, such as housekeeping are automatically scheduled for timely completion. A done list helps users to keep track of all completed tasks. The built-in check list assures that work process will meet the applicable processes and procedures. Users can hand write comments or drawings with an electronic pen that allows the users to directly interface information on the screen.
Rendigs, Richard R.; Bothner, Michael H.
2004-01-01
This manual describes the operation and testing procedures for two models of a multi-port suspended sediment sampler that are moored in the coastal ocean and that collect samples on a programmable time schedule that can be interrupted to collect during a storm. The ability to sense and collect samples before, during, and after the height of a storm is a unique feature of these instruments because it provides samples during conditions when it is difficult or impossible to sample from a surface ship. The sensors used to trigger storm sampling are a transmissometer or a pressure sensor. The purpose of such samples is to assess composition and concentration of sediment resuspended from the seafloor during storms and subsequently transported within the coastal system. Both light transmission and the standard deviation of pressure from surface waves correlate with the passage of major storms. The instruments successfully identified the onset of storms and collected samples before, during, and after the storm maximum as programmed. The accuracy of determining suspended matter concentrations collected by the sediment sampler has not been fully evaluated. Preliminary laboratory tests using a suspension of muddy sediment collected in a near-bottom sediment trap yielded excellent results. However in laboratory tests with different sediment types, the suspended matter concentrations determined with these samplers became less accurate with increasing average grain size. Future calibration work is necessary and should be conducted in a facility that ideally has a water depth of at least 30 feet to prevent cavitation of the pump that draws sea water through the filters. The test facility should also have the capability for adding suspended matter of known composition and concentration to a fixed volume of seawater that is well mixed.
Hoffman, G.L.; Fishman, M. J.; Garbarino, J.R.
1996-01-01
Water samples for trace-metal determinations routinely have been prepared in open laboratories. For example, the U.S. Geological Survey method I-3485-85 (Extraction Procedure, for Water- Suspended Sediment) is performed in a laboratory hood on a laboratory bench without any special precautions to control airborne contamination. This method tends to be contamination prone for several trace metals primarily because the samples are transferred, acidified, digested, and filtered in an open laboratory environment. To reduce trace-metal contamination of digested water samples, procedures were established that rely on minimizing sample-transfer steps and using a class-100 clean bench during sample filtration. This new procedure involves the following steps: 1. The sample is acidified with HCl directly in the original water-sample bottle. 2. The water-sample bottle with the cap secured is heated in a laboratory oven. 3. The digestate is filtered in a class-100 laminar-flow clean bench. The exact conditions used (that is, oven temperature, time of heating, and filtration methods) for this digestion procedure are described. Comparisons between the previous U.S Geological Survey open-beaker method I-3485-85 and the new in-bottle procedure for synthetic and field-collected water samples are given. When the new procedure is used, blank concentrations for most trace metals determined are reduced significantly.
A Method for Developing Standard Patient Education Program.
Lura, Carolina Bryne; Hauch, Sophie Misser Pallesgaard; Gøeg, Kirstine Rosenbeck; Pape-Haugaard, Louise
2018-01-01
In Denmark, patients being treated on Haematology Outpatients Departments get instructed to self-manage their blood sample collection from Central Venous Catheter (CVC). However, this is a complex and risky procedure, which can jeopardize patient safety. The aim of the study was to suggest a method for developing standard digital patient education programs for patients in self-administration of blood samples drawn from CVC. The Design Science Research Paradigm was used to develop a digital patient education program, called PAVIOSY, to increase patient safety during execution of the blood sample collection procedure by using videos for teaching as well as procedural support. A step-by-step guide was developed and used as basis for making the videos. Quality assurance through evaluation with a nurse was conducted on both the step-by-step guide and the videos. The quality assurance evaluation of the videos showed; 1) Errors due to the order of the procedure can be determined by reviewing the videos despite that the guide was followed. 2) Videos can be used to identify errors - important for patient safety - in the procedure, which are not identifiable in a written script. To ensure correct clinical content of the educational patient system, health professionals must be engaged early in the development of content and design phase.
The purpose of this SOP is to describe how to collect, store, and ship tap and drinking water samples for analysis by EPA Method 525.2 (revision 1.0) and EPA method 531.1 (revision 3) for the NHEXAS Arizona project. This SOP provides a brief description of the sample containers,...
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2009-01-01
The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's Lab Master data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality control samples analyzed from July 2003 through June 2005. Results for the quality-control samples for 20 analytical procedures were evaluated for bias and precision. Control charts indicate that data for five of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, pH, silicon, and sodium. Seven of the analytical procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits; these procedures were: dissolved organic carbon, chloride, nitrate (ion chromatograph), nitrite, silicon, sodium, and sulfate. The calcium and magnesium procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The total aluminum and specific conductance procedures were biased for the high-concentration and low-concentration samples, but were within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 17 of 18 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 18 of the 22 analytes. At least 85 percent of the samples met data-quality objectives for all analytes except total monomeric aluminum (82 percent of samples met objectives), total aluminum (77 percent of samples met objectives), chloride (80 percent of samples met objectives), fluoride (76 percent of samples met objectives), and nitrate (ion chromatograph) (79 percent of samples met objectives). The ammonium and total dissolved nitrogen did not meet the data-quality objectives. Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality over the time period, with ratings for each sample in the satisfactory, good, and excellent ranges or less than 10 percent error. The P-sample (low-ionic-strength constituents) analysis had one marginal and two unsatisfactory ratings for the chloride procedure. The T-sample (trace constituents)analysis had two unsatisfactory ratings and one high range percent error for the aluminum procedure. The N-sample (nutrient constituents) analysis had one marginal rating for the nitrate procedure. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 84 percent of the samples met data-quality objectives for 11 of the 14 analytes; the exceptions were ammonium, total aluminum, and acid-neutralizing capacity. The ammonium procedure did not meet data quality objectives in all studies. Data-quality objectives were not met in 23 percent of samples analyzed for total aluminum and 45 percent of samples analyzed acid-neutralizing capacity. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 86 percent of the samples analyzed for calcium, chloride, fluoride, magnesium, pH, potassium, sodium, and sulfate. Data-quality objectives were not met by samples analyzed for fluoride.
General introduction for the “National Field Manual for the Collection of Water-Quality Data”
,
2018-02-28
BackgroundAs part of its mission, the U.S. Geological Survey (USGS) collects data to assess the quality of our Nation’s water resources. A high degree of reliability and standardization of these data are paramount to fulfilling this mission. Documentation of nationally accepted methods used by USGS personnel serves to maintain consistency and technical quality in data-collection activities. “The National Field Manual for the Collection of Water-Quality Data” (NFM) provides documented guidelines and protocols for USGS field personnel who collect water-quality data. The NFM provides detailed, comprehensive, and citable procedures for monitoring the quality of surface water and groundwater. Topics in the NFM include (1) methods and protocols for sampling water resources, (2) methods for processing samples for analysis of water quality, (3) methods for measuring field parameters, and (4) specialized procedures, such as sampling water for low levels of mercury and organic wastewater chemicals, measuring biological indicators, and sampling bottom sediment for chemistry. Personnel who collect water-quality data for national USGS programs and projects, including projects supported by USGS cooperative programs, are mandated to use protocols provided in the NFM per USGS Office of Water Quality Technical Memorandum 2002.13. Formal training, for example, as provided in the USGS class, “Field Water-Quality Methods for Groundwater and Surface Water,” and field apprenticeships supplement the guidance provided in the NFM and ensure that the data collected are high quality, accurate, and scientifically defensible.
Wei, Yi; Gadaria-Rathod, Neha; Epstein, Seth; Asbell, Penny
2013-12-23
To provide standard operating procedures (SOPs) for measuring tear inflammatory cytokine concentrations and to validate the resulting profile as a minimally invasive objective metric and biomarker of ocular surface inflammation for use in multicenter clinical trials on dry eye disease (DED). Standard operating procedures were established and then validated with cytokine standards, quality controls, and masked tear samples collected from local and distant clinical sites. The concentrations of the inflammatory cytokines in tears were quantified using a high-sensitivity human cytokine multiplex kit. A panel of inflammatory cytokines was initially investigated, from which four key inflammatory cytokines (IL-1β, IL-6, INF-γ, and TNF-α) were chosen. Results with cytokine standards statistically satisfied the manufacturer's quality control criteria. Results with pooled tear samples were highly reproducible and reliable with tear volumes ranging from 4 to 10 μL. Incorporation of the SOPs into clinical trials was subsequently validated. Tear samples were collected at a distant clinical site, stored, and shipped to our Biomarker Laboratory, where a masked analysis of the four tear cytokines was successfully performed. Tear samples were also collected from a feasibility study on DED. Inflammatory cytokine concentrations were decreased in tears of subjects who received anti-inflammatory treatment. Standard operating procedures for human tear cytokine assessment suitable for multicenter clinical trials were established. Tear cytokine profiling using these SOPs may provide objective metrics useful for diagnosing, classifying, and analyzing treatment efficacy in inflammatory conditions of the ocular surface, which may further elucidate the mechanisms involved in the pathogenesis of ocular surface disease.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wild, M.; Rouhani, S.
1995-02-01
A typical site investigation entails extensive sampling and monitoring. In the past, sampling plans have been designed on purely ad hoc bases, leading to significant expenditures and, in some cases, collection of redundant information. In many instances, sampling costs exceed the true worth of the collected data. The US Environmental Protection Agency (EPA) therefore has advocated the use of geostatistics to provide a logical framework for sampling and analysis of environmental data. Geostatistical methodology uses statistical techniques for the spatial analysis of a variety of earth-related data. The use of geostatistics was developed by the mining industry to estimate oremore » concentrations. The same procedure is effective in quantifying environmental contaminants in soils for risk assessments. Unlike classical statistical techniques, geostatistics offers procedures to incorporate the underlying spatial structure of the investigated field. Sample points spaced close together tend to be more similar than samples spaced further apart. This can guide sampling strategies and determine complex contaminant distributions. Geostatistic techniques can be used to evaluate site conditions on the basis of regular, irregular, random and even spatially biased samples. In most environmental investigations, it is desirable to concentrate sampling in areas of known or suspected contamination. The rigorous mathematical procedures of geostatistics allow for accurate estimates at unsampled locations, potentially reducing sampling requirements. The use of geostatistics serves as a decision-aiding and planning tool and can significantly reduce short-term site assessment costs, long-term sampling and monitoring needs, as well as lead to more accurate and realistic remedial design criteria.« less
CTEPP STANDARD OPERATING PROCEDURE FOR HANDLING SAMPLE AND DATA CUSTODY (SOP-2.26)
This SOP describes the method for handling sample custody. A standardized Chain-of-Custody (CoC) Record is used to document the sample/data custody. Each participant is assigned one CoC Record for the samples/data collected at their home and/or day care center.
NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR DUPLICATE SAMPLING (F12)
This SOP is designed to provide both general and specific guidance for the collection of duplicate samples by Harvard School of Public Health/Emory University for the NHEXAS project. The purpose of the duplicate sampling was to ensure that the value obtained for a sample was ind...
Implementation guide for turbidity threshold sampling: principles, procedures, and analysis
Jack Lewis; Rand Eads
2009-01-01
Turbidity Threshold Sampling uses real-time turbidity and river stage information to automatically collect water quality samples for estimating suspended sediment loads. The system uses a programmable data logger in conjunction with a stage measurement device, a turbidity sensor, and a pumping sampler. Specialized software enables the user to control the sampling...
Grand, I; Bellon-Fontaine, M-N; Herry, J-M; Hilaire, D; Moriconi, F-X; Naïtali, M
2011-09-01
The standard test methods used to assess the efficiency of a disinfectant applied to surfaces are often based on counting the microbial survivors sampled in a liquid, but total cell removal from surfaces is seldom achieved. One might therefore wonder whether evaluations of microbial survivors in liquid-sampled cells are representative of the levels of survivors in whole populations. The present study was thus designed to determine the "damaged/undamaged" status induced by a peracetic acid disinfection for Bacillus atrophaeus spores deposited on glass coupons directly on this substrate and to compare it to the status of spores collected in liquid by a sampling procedure. The method utilized to assess the viability of both surface-associated and liquid-sampled spores included fluorescence labeling with a combination of Syto 61 and Chemchrome V6 dyes and quantifications by analyzing the images acquired by confocal laser scanning microscopy. The principal result of the study was that the viability of spores sampled in the liquid was found to be poorer than that of surface-associated spores. For example, after 2 min of peracetic acid disinfection, less than 17% ± 5% of viable cells were detected among liquid-sampled cells compared to 79% ± 5% or 47% ± 4%, respectively, when the viability was evaluated on the surface after or without the sampling procedure. Moreover, assessments of the survivors collected in the liquid phase, evaluated using the microscopic method and standard plate counts, were well correlated. Evaluations based on the determination of survivors among the liquid-sampled cells can thus overestimate the efficiency of surface disinfection procedures.
Grand, I.; Bellon-Fontaine, M.-N.; Herry, J.-M.; Hilaire, D.; Moriconi, F.-X.; Naïtali, M.
2011-01-01
The standard test methods used to assess the efficiency of a disinfectant applied to surfaces are often based on counting the microbial survivors sampled in a liquid, but total cell removal from surfaces is seldom achieved. One might therefore wonder whether evaluations of microbial survivors in liquid-sampled cells are representative of the levels of survivors in whole populations. The present study was thus designed to determine the “damaged/undamaged” status induced by a peracetic acid disinfection for Bacillus atrophaeus spores deposited on glass coupons directly on this substrate and to compare it to the status of spores collected in liquid by a sampling procedure. The method utilized to assess the viability of both surface-associated and liquid-sampled spores included fluorescence labeling with a combination of Syto 61 and Chemchrome V6 dyes and quantifications by analyzing the images acquired by confocal laser scanning microscopy. The principal result of the study was that the viability of spores sampled in the liquid was found to be poorer than that of surface-associated spores. For example, after 2 min of peracetic acid disinfection, less than 17% ± 5% of viable cells were detected among liquid-sampled cells compared to 79% ± 5% or 47% ± 4%, respectively, when the viability was evaluated on the surface after or without the sampling procedure. Moreover, assessments of the survivors collected in the liquid phase, evaluated using the microscopic method and standard plate counts, were well correlated. Evaluations based on the determination of survivors among the liquid-sampled cells can thus overestimate the efficiency of surface disinfection procedures. PMID:21742922
Calibration of collection procedures for the determination of precipitation chemistry
James N. Galloway; Gene E. Likens
1976-01-01
Precipitation is currently collected by several methods, including several different designs of collection apparatus. We are investigating these differing methods and designs to determine which gives the most representative sample of precipitation for the analysis of some 25 chemical parameters. The experimental site, located in Ithaca, New York, has 22 collectors of...
Kanai, Yae; Nishihara, Hiroshi; Miyagi, Yohei; Tsuruyama, Tatsuhiro; Taguchi, Kenichi; Katoh, Hiroto; Takeuchi, Tomoyo; Gotoh, Masahiro; Kuramoto, Junko; Arai, Eri; Ojima, Hidenori; Shibuya, Ayako; Yoshida, Teruhiko; Akahane, Toshiaki; Kasajima, Rika; Morita, Kei-Ichi; Inazawa, Johji; Sasaki, Takeshi; Fukayama, Masashi; Oda, Yoshinao
2018-02-01
Genome research using appropriately collected pathological tissue samples is expected to yield breakthroughs in the development of biomarkers and identification of therapeutic targets for diseases such as cancers. In this connection, the Japanese Society of Pathology (JSP) has developed "The JSP Guidelines on the Handling of Pathological Tissue Samples for Genomic Research" based on an abundance of data from empirical analyses of tissue samples collected and stored under various conditions. Tissue samples should be collected from appropriate sites within surgically resected specimens, without disturbing the features on which pathological diagnosis is based, while avoiding bleeding or necrotic foci. They should be collected as soon as possible after resection: at the latest within about 3 h of storage at 4°C. Preferably, snap-frozen samples should be stored in liquid nitrogen (about -180°C) until use. When intending to use genomic DNA extracted from formalin-fixed paraffin-embedded tissue, 10% neutral buffered formalin should be used. Insufficient fixation and overfixation must both be avoided. We hope that pathologists, clinicians, clinical laboratory technicians and biobank operators will come to master the handling of pathological tissue samples based on the standard operating procedures in these Guidelines to yield results that will assist in the realization of genomic medicine. © 2018 The Authors. Pathology International published by Japanese Society of Pathology and John Wiley & Sons Australia, Ltd.
Filtration of water-sediment samples for the determination of organic compounds
Sandstrom, Mark W.
1995-01-01
This report describes the equipment and procedures used for on-site filtration of surface-water and ground-water samples for determination of organic compounds. Glass-fiber filters and a positive displacement pumping system are suitable for processing most samples for organic analyses. An optional system that uses disposable in-line membrane filters is suitable for a specific gas chromatography/mass spectrometry, selected-ion monitoring analytical method for determination of organonitrogen herbicides. General procedures to minimize contamination of the samples include preparing a clean workspace at the site, selecting appropriate sample-collection materials, and cleaning of the equipment with detergent, tap water, and methanol.
40 CFR 65.158 - Performance test procedures for control devices.
Code of Federal Regulations, 2012 CFR
2012-07-01
... loading period during which regulated materials are loaded, and samples shall be collected using... applicable. The regulated material concentration and percent reduction may be measured as either total regulated material or as TOC (minus methane and ethane) according to the procedures specified. (1) Method 1...
40 CFR 65.158 - Performance test procedures for control devices.
Code of Federal Regulations, 2013 CFR
2013-07-01
... loading period during which regulated materials are loaded, and samples shall be collected using... applicable. The regulated material concentration and percent reduction may be measured as either total regulated material or as TOC (minus methane and ethane) according to the procedures specified. (1) Method 1...
40 CFR 65.158 - Performance test procedures for control devices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... loading period during which regulated materials are loaded, and samples shall be collected using... applicable. The regulated material concentration and percent reduction may be measured as either total regulated material or as TOC (minus methane and ethane) according to the procedures specified. (1) Method 1...
Community duplicate diet methodology: A new tool for estimating dietary exposure to pesticides
An observational field study was conducted to assess the feasibility of a community duplicate diet collection method; a dietary monitoring procedure that is population-based. The purpose was to establish an alternative procedure to duplicate diet sampling that would be more effi...
Use of Electronic Hand-held Devices for Collection of Savannah River Site Environmental Data - 13329
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marberry, Hugh; Moore, Winston
2013-07-01
Savannah River Nuclear Solutions has begun using Xplore Tablet PC's to collect data in the field for soil samples, groundwater samples, air samples and round sheets at the Savannah River Site (SRS). EPA guidelines for groundwater sampling are incorporated into the application to ensure the sample technician follows the proper protocol. The sample technician is guided through the process for sampling and round sheet data collection by a series of menus and input boxes. Field measurements and well stabilization information are entered into the tablet for uploading into Environmental Restoration Data Management System (ERDMS). The process helps to eliminate inputmore » errors and provides data integrity. A soil sample technician has the ability to collect information about location of sample, field parameter, describe the soil sample, print bottle labels, and print chain of custody for the sample that they have collected. An air sample technician has the ability to provide flow, pressure, hours of operation, print bottle labels and chain of custody for samples they collect. Round sheets are collected using the information provided in the various procedures. The data are collected and uploaded into ERDMS. The equipment used is weather proof and hardened for the field use. Global Positioning System (GPS) capabilities are integrated into the applications to provide the location where samples were collected and to help sample technicians locate wells that are not visited often. (authors)« less
78 FR 63568 - Proposed Collection; Comment Request for Rev. Proc. 2007-35
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-24
... Revenue Procedure 2007-35, Statistical Sampling for purposes of Section 199. DATES: Written comments... . SUPPLEMENTARY INFORMATION: Title: Statistical Sampling for purposes of Section 199. OMB Number: 1545-2072... statistical sampling may be used in purposes of section 199, which provides a deduction for income...
Microbiota in Exhaled Breath Condensate and the Lung.
Glendinning, Laura; Wright, Steven; Tennant, Peter; Gill, Andrew C; Collie, David; McLachlan, Gerry
2017-06-15
The lung microbiota is commonly sampled using relatively invasive bronchoscopic procedures. Exhaled breath condensate (EBC) collection potentially offers a less invasive alternative for lung microbiota sampling. We compared lung microbiota samples retrieved by protected specimen brushings (PSB) and exhaled breath condensate collection. We also sought to assess whether aerosolized antibiotic treatment would influence the lung microbiota and whether this change could be detected in EBC. EBC was collected from 6 conscious sheep and then from the same anesthetized sheep during mechanical ventilation. Following the latter EBC collection, PSB samples were collected from separate sites within each sheep lung. On the subsequent day, each sheep was then treated with nebulized colistimethate sodium. Two days after nebulization, EBC and PSB samples were again collected. Bacterial DNA was quantified using 16S rRNA gene quantitative PCR. The V2-V3 region of the 16S rRNA gene was amplified by PCR and sequenced using Illumina MiSeq. Quality control and operational taxonomic unit (OTU) clustering were performed with mothur. The EBC samples contained significantly less bacterial DNA than the PSB samples. The EBC samples from anesthetized animals clustered separately by their bacterial community compositions in comparison to the PSB samples, and 37 bacterial OTUs were identified as differentially abundant between the two sample types. Despite only low concentrations of colistin being detected in bronchoalveolar lavage fluid, PSB samples were found to differ by their bacterial compositions before and after colistimethate sodium treatment. Our findings indicate that microbiota in EBC samples and PSB samples are not equivalent. IMPORTANCE Sampling of the lung microbiota usually necessitates performing bronchoscopic procedures that involve a hospital visit for human participants and the use of trained staff. The inconvenience and perceived discomfort of participating in this kind of research may deter healthy volunteers and may not be a safe option for patients with advanced lung disease. This study set out to evaluate a less invasive method for collecting lung microbiota samples by comparing samples taken via protected specimen brushings (PSB) to those taken via exhaled breath condensate (EBC) collection. We found that there was less bacterial DNA in EBC samples compared with that in PSB samples and that there were differences between the bacterial communities in the two sample types. We conclude that while EBC and PSB samples do not produce equivalent microbiota samples, the study of the EBC microbiota may still be of interest. Copyright © 2017 Glendinning et al.
SAM Companion Documents and Sample Collection Procedures provide information intended to complement the analytical methods listed in Selected Analytical Methods for Environmental Remediation and Recovery (SAM).
Chemical anesthesia of Northern sea otters (Enhydra lutris): Results of past field studies
Monson, Daniel H.; McCormick, C.; Ballachey, Brenda E.
2001-01-01
Between 1987 and 1997, we chemically immobilized 597 wild sea otters (Enhydra lutris) in Alaska for the collection of biological samples or for surgical instrumentation. One drug-related sea otter fatality occurred during this time. Fentanyl in combination with diazepam produced consistent, smooth inductions with minimal need for supplemental anesthetics during procedures lasting 30-40 min. Antagonism with naltrexone or naloxone was rapid and complete, although we observed narcotic recycling in sea otters treated with naloxone. For surgical procedures, we recommend a fentanyl target dose of 0.33 mg/kg of body mass and diazepam at 0.11 mg/kg. For nonsurgical biological sample collection procedures, we recommend fentanyl at 0.22 mg/kg and diazepam at 0.07 mg/kg. We advise the use of the opioid antagonist naltrexone at a ratio of 2:1 to the total fentanyl administered during processing.
DICHOTOMOUS SAMPLER - A PRACTICAL APPROACH TO AEROSOL FRACTIONATION AND COLLECTION
Procedures to size fractionate, collect, and analyze ambient concentrations of particulate matter are described. Emphasis is placed on the design and characteristics of the single-stage dichotomous sampler. A new inlet is described that samples aerosol independent of wind speed a...
Young, Stacie T.M.; Ball, Marcael T.J.
2003-01-01
Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. This program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream. For this program, rainfall data was collected at two sites, continuous streamflow data at three sites, and water-quality data at five sites, which include the three streamflow sites. This report summarizes rainfall, streamflow, and water-quality data collected between July 1, 2002 to June 30, 2003. A total of 28 samples were collected over five storms during July 1, 2002 to June 30, 2003. For two of the five storms, five grab samples and three flow-weighted timecomposite samples were collected. Grab samples were collected nearly simultaneously at all five sites, and flow-weighted timecomposite samples were collected at the three sites equipped with automatic samplers. The other three storms were partially sampled, where only flow-weighted time-composite samples were collected and/or not all stations were sampled. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, copper, lead, and zinc). Grab samples were additionally analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Quality-assurance/qualitycontrol samples, collected during storms and during routine maintenance, were also collected to verify analytical procedures and insure proper cleaning of equipment.
Image-guided interventional procedures in the dog and cat.
Vignoli, Massimo; Saunders, Jimmy H
2011-03-01
Medical imaging is essential for the diagnostic workup of many soft tissue and bone lesions in dogs and cats, but imaging modalities do not always allow the clinician to differentiate inflammatory or infectious conditions from neoplastic disorders. This review describes interventional procedures in dogs and cats for collection of samples for cytological or histopathological examinations under imaging guidance. It describes the indications and procedures for imaging-guided sampling, including ultrasound (US), computed tomography (CT), magnetic resonance imaging and fluoroscopy. US and CT are currently the modalities of choice in interventional imaging. Copyright © 2009 Elsevier Ltd. All rights reserved.
Wagner, Richard J.; Mattraw, Harold C.; Ritz, George F.; Smith, Brett A.
2000-01-01
The U.S. Geological Survey uses continuous water-quality monitors to assess variations in the quality of the Nation's surface water. A common system configuration for data collection is the four-parameter water-quality monitoring system, which collects temperature, specific conductance, dissolved oxygen, and pH data, although systems can be configured to measure other properties such as turbidity or chlorophyll. The sensors that are used to measure these water properties require careful field observation, cleaning, and calibration procedures, as well as thorough procedures for the computation and publication of final records. Data from sensors can be used in conjunction with collected samples and chemical analyses to estimate chemical loads. This report provides guidelines for site-selection considerations, sensor test methods, field procedures, error correction, data computation, and review and publication processes. These procedures have evolved over the past three decades, and the process continues to evolve with newer technologies.
STS-55 Payload Specialist Schlegel collects fungi sample at SL-D2 Rack 1
NASA Technical Reports Server (NTRS)
1993-01-01
STS-55 German Payload Specialist 2 Hans Schlegel, wearing lightweight headset, collects fungi sample while working at Spacelab Deutsche 2 (SL-D2) science module Rack 1 Work Bench. Schlegel is conducting these procedures in conjunction with the 'Fruiting Body Development of Fungi' experiment. Schlegel was one of two payload specialists representing the German Aerospace Research Establishment (DLR) on the 10-day spacelab mission.
Rapid Profile: A Second Language Screening Procedure.
ERIC Educational Resources Information Center
Mackey, Alison; And Others
1991-01-01
Rapid Profile, developed by Manfred Pienemann of National Languages Institute of Australia/Language Acquisition Research Centre, is a computer-based procedure for screening speech samples collected from language learners to assess their level of language development as compared to standard patterns in the acquisition of the target language. Rapid…
An Investigation of the Efficiency of Various Observational Procedures.
ERIC Educational Resources Information Center
Kissel, Mary Ann; Yeager, John L.
Several sampling procedures for collecting observational data on student activities were studied in an effort to determine their relative efficiency. The setting was a fifth grade Individually Prescribed Instruction (IPI) mathematics class of thirty-three pupils. A criterion measure was obtained by cumulating the measurements obtained on the…
50 CFR 679.6 - Exempted fisheries.
Code of Federal Regulations, 2011 CFR
2011-10-01
.... (iv) Experimental design (e.g., sampling procedures, the data and samples to be collected, and... Exempted fisheries. (a) General. For limited experimental purposes, the Regional Administrator may... basis of incomplete information or design flaws, the applicant will be provided an opportunity to...
50 CFR 679.6 - Exempted fisheries.
Code of Federal Regulations, 2012 CFR
2012-10-01
.... (iv) Experimental design (e.g., sampling procedures, the data and samples to be collected, and... Exempted fisheries. (a) General. For limited experimental purposes, the Regional Administrator may... basis of incomplete information or design flaws, the applicant will be provided an opportunity to...
50 CFR 679.6 - Exempted fisheries.
Code of Federal Regulations, 2013 CFR
2013-10-01
.... (iv) Experimental design (e.g., sampling procedures, the data and samples to be collected, and... Exempted fisheries. (a) General. For limited experimental purposes, the Regional Administrator may... basis of incomplete information or design flaws, the applicant will be provided an opportunity to...
50 CFR 679.6 - Exempted fisheries.
Code of Federal Regulations, 2014 CFR
2014-10-01
.... (iv) Experimental design (e.g., sampling procedures, the data and samples to be collected, and... Exempted fisheries. (a) General. For limited experimental purposes, the Regional Administrator may... basis of incomplete information or design flaws, the applicant will be provided an opportunity to...
50 CFR 679.6 - Exempted fisheries.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... (iv) Experimental design (e.g., sampling procedures, the data and samples to be collected, and... Exempted fisheries. (a) General. For limited experimental purposes, the Regional Administrator may... basis of incomplete information or design flaws, the applicant will be provided an opportunity to...
Bernini, Patrizia; Bertini, Ivano; Luchinat, Claudio; Nincheri, Paola; Staderini, Samuele; Turano, Paola
2011-04-01
(1)H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0-4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.
Blood venous sample collection: Recommendations overview and a checklist to improve quality.
Giavarina, Davide; Lippi, Giuseppe
2017-07-01
The extra-analytical phases of the total testing process have substantial impact on managed care, as well as an inherent high risk of vulnerability to errors which is often greater than that of the analytical phase. The collection of biological samples is a crucial preanalytical activity. Problems or errors occurring shortly before, or soon after, this preanalytical step may impair sample quality and characteristics, or else modify the final results of testing. The standardization of fasting requirements, rest, patient position and psychological state of the patient are therefore crucial for mitigating the impact of preanalytical variability. Moreover, the quality of materials used for collecting specimens, along with their compatibility, can guarantee sample quality and persistence of chemical and physical characteristics of the analytes over time, so safeguarding the reliability of testing. Appropriate techniques and sampling procedures are effective to prevent problems such as hemolysis, undue clotting in the blood tube, draw of insufficient sample volume and modification of analyte concentration. An accurate identification of both patient and blood samples is a key priority as for other healthcare activities. Good laboratory practice and appropriate training of operators, by specifically targeting collection of biological samples, blood in particular, may greatly improve this issue, thus lowering the risk of errors and their adverse clinical consequences. The implementation of a simple and rapid check-list, including verification of blood collection devices, patient preparation and sampling techniques, was found to be effective for enhancing sample quality and reducing some preanalytical errors associated with these procedures. The use of this tool, along with implementation of objective and standardized systems for detecting non-conformities related to unsuitable samples, can be helpful for standardizing preanalytical activities and improving the quality of laboratory diagnostics, ultimately helping to reaffirm a "preanalytical" culture founded on knowledge and real risk perception. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Syta, Olga; Rozum, Karol; Choińska, Marta; Zielińska, Dobrochna; Żukowska, Grażyna Zofia; Kijowska, Agnieszka; Wagner, Barbara
2014-11-01
Analytical procedure for the comprehensive chemical characterization of samples from medieval Nubian wall-paintings by means of portable X-ray fluorescence (pXRF), laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) and Raman spectroscopy (RS) was proposed in this work. The procedure was used for elemental and molecular investigations of samples from archeological excavations in Nubia (modern southern Egypt and northern Sudan). Numerous remains of churches with painted decorations dated back to the 7th-14th century were excavated in the region of medieval kingdoms of Nubia but many aspects of this art and its technology are still unknown. Samples from the selected archeological sites (Faras, Old Dongola and Banganarti) were analyzed in the form of transfers (n = 26), small fragments collected during the excavations (n = 35) and cross sections (n = 15). XRF was used to collect data about elemental composition, LA-ICPMS allowed mapping of selected elements, while RS was used to get the molecular information about the samples. The preliminary results indicated the usefulness of the proposed analytical procedure for distinguishing the substances, from both the surface and sub-surface domains of the wall-paintings. The possibility to identify raw materials from the wall-paintings will be used in the further systematic, archeometric studies devoted to the detailed comparison of various historic Nubian centers.
Exhaled Breath Condensate Collection in the Mechanically Ventilated Patient
Carter, Stewart R; Davis, Christopher S; Kovacs, Elizabeth J
2012-01-01
Collection of exhaled breath condensate (EBC) is a non-invasive means of sampling the airway-lining fluid of the lungs. EBC contains numerous measurable mediators, whose analysis could change the management of patients with certain pulmonary diseases. While initially popularized in investigations involving spontaneously breathing patients, an increasing number of studies have been performed using EBC in association with mechanical ventilation. Collection of EBC in mechanically ventilated patients follows basic principles of condensation, but is influenced by multiple factors. Effective collection requires selection of a collection device, adequate minute ventilation, low cooling temperatures, and sampling times of greater than ten minutes. Condensate can be contaminated by saliva, which needs to be filtered. Dilution of samples occurs secondary to distilled water in vapors and humidification in the ventilator circuit. Dilution factors may need to be employed when investigating non-volatile biomarkers. Storage and analysis should occur promptly at −70° C to −80° C to prevent rapid degradation of samples. The purpose of this review is to examine and describe methodologies and problems of EBC collection in mechanically ventilated patients. A straightforward and safe framework has been established to investigate disease processes in this population, yet technical aspects of EBC collection still exist that prevent clinical practicality of this technology. These include a lack of standardization of procedure and analysis of biomarkers, and of normal reference ranges for mediators in healthy individuals. Once these procedural aspects have been addressed, EBC could serve as a non-invasive alternative to invasive evaluation of lungs in mechanically ventilated patients. PMID:22398157
Methods for collection and analysis of aquatic biological and microbiological samples
Greeson, Phillip E.; Ehlke, T.A.; Irwin, G.A.; Lium, B.W.; Slack, K.V.
1977-01-01
Chapter A4 contains methods used by the U.S. Geological Survey to collect, preserve, and analyze waters to determine their biological and microbiological properties. Part 1 discusses biological sampling and sampling statistics. The statistical procedures are accompanied by examples. Part 2 consists of detailed descriptions of more than 45 individual methods, including those for bacteria, phytoplankton, zooplankton, seston, periphyton, macrophytes, benthic invertebrates, fish and other vertebrates, cellular contents, productivity, and bioassays. Each method is summarized, and the application, interferences, apparatus, reagents, collection, analysis, calculations, reporting of results, precision and references are given. Part 3 consists of a glossary. Part 4 is a list of taxonomic references.
NASA Astrophysics Data System (ADS)
Kusumo, B. H.; Sukartono, S.; Bustan, B.
2018-02-01
Measuring soil organic carbon (C) using conventional analysis is tedious procedure, time consuming and expensive. It is needed simple procedure which is cheap and saves time. Near infrared technology offers rapid procedure as it works based on the soil spectral reflectance and without any chemicals. The aim of this research is to test whether this technology able to rapidly measure soil organic C in rice paddy field. Soil samples were collected from rice paddy field of Lombok Island Indonesia, and the coordinates of the samples were recorded. Parts of the samples were analysed using conventional analysis (Walkley and Black) and some other parts were scanned using near infrared spectroscopy (NIRS) for soil spectral collection. Partial Least Square Regression (PLSR) Models were developed using data of soil C analysed using conventional analysis and data from soil spectral reflectance. The models were moderately successful to measure soil C in rice paddy field of Lombok Island. This shows that the NIR technology can be further used to monitor the C change in rice paddy soil.
77 FR 2697 - Proposed Information Collection; Comment Request; Annual Services Report
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-19
... and from a sample of small- and medium-sized businesses selected using a stratified sampling procedure... be canvassed when the sample is re-drawn, while nearly all of the small- and medium-sized firms from...); Educational Services (NAICS 61); Health Care and Social Assistance (NAICS 62); Arts, Entertainment, and...
Turbidity threshold sampling for suspended sediment load estimation
Jack Lewis; Rand Eads
2001-01-01
Abstract - The paper discusses an automated procedure for measuring turbidity and sampling suspended sediment. The basic equipment consists of a programmable data logger, an in situ turbidimeter, a pumping sampler, and a stage-measuring device. The data logger program employs turbidity to govern sample collection during each transport event. Mounting configurations and...
Methodological Issues of Sample Collection and Analysis of Exhaled Breath
Recommended standardized procedures have been developed for measurement of exhaled lower respiratory nitric oxide (NO) and nasal NO. It would be desirable to develop similar guidelines for the sampling of exhaled breath related to other compounds. For such systemic volatile o...
Sampling and Analysis Plan - Guidance and Template v.4 - General Projects - 04/2014
This Sampling and Analysis Plan (SAP) guidance and template is intended to assist organizations in documenting the procedural and analytical requirements for one-time, or time-limited, projects involving the collection of water, soil, sediment, or other
Katz, B.G.; Collins, J.J.
1998-01-01
A cooperative study between the Florida Department of Environmental Protection (FDEP) and the U.S. Geological Survey was conducted to assess the integrity of selected water-quality data collected at 150 sites in the FDEP Surface-Water Ambient Monitoring Program (SWAMP) in Florida. The assessment included determining the consistency of the water-quality data collected statewide, including commonality of monitoring procedures and analytes, screening of the gross validity of a chemical analysis, and quality assurance and quality control (QA/QC) procedures. Four tests were used to screen data at selected SWAMP sites to estimate the gross validity of selected chemical data: (1) the ratio of dissolved solids (in milligrams per liter) to specific conductance (in microsiemens per centimeter); (2) the ratio of total cations (in milliequivalents per liter) multiplied by 100 to specific conductance (in microsiemens per centimeter); (3) the ratio of total anions (in milliequivalents per liter) multiplied by 100 to specific conductance (in microsiemens per centimeter); and (4) the ionic charge-balance error. Although the results of the four screening tests indicate that the chemical data generally are quite reliable, the extremely small number of samples (less than 5 percent of the total number of samples) with sufficient chemical information to run the tests may not provide a representative indication of the analytical accuracy of all laboratories in the program. In addition to the four screening tests, unusually low or high values were flagged for field and laboratory pH (less than 4.0 and greater than 9.0) and specific conductance (less than 10 and greater than 10,000 microsiemens per centimeter). The numbers of flagged data were less than 1 percent of the 19,937 water samples with pH values and less than 0.6 percent of the 16,553 water samples with specific conductance values. Thirty-four agencies responded to a detailed questionnaire that was sent to more than 60 agencies involved in the collection and analysis of surface-water-quality data for SWAMP. The purpose of the survey was to evaluate quality assurance methods and consistency of methods statewide. Information was compiled and summarized on monitoring network design, data review and upload procedures, laboratory and field sampling methods, and data practices. Currently, most agencies that responded to the survey follow FDEP-approved QA/QC protocol for sampling and have quality assurance practices for recording and reporting data. Also, most agencies responded that calibration procedures were followed in the laboratory for analysis of data, but no responses were given about the specific procedures. Approximately 50 percent of the respondents indicated that laboratory analysis methods have changed over time. With so many laboratories involved in analyzing samples for SWAMP, it is difficult to compare water quality from one site to another due to different reporting conventions for chemical constituents and different analytical methods over time. Most agencies responded that calibration methods are followed in the field, but no specific details were provided. Grab samples are the most common method of collection. Other data screening procedures are necessary to further evaluate the validity of chemical data collected at SWAMP sites. High variability in the concentration of targeted constituents may signal analytical problems, but more likely changes in concentration are related to hydrologic conditions. This underscores the need for accurate measurements of discharge, lake stage, tidal stage at the time of sampling so that changes in constituent concentrations can be properly evaluated and fluxes (loads) of nutrients or metals, for example, can be calculated and compared over time.
Balejo, Rodrigo Dalla Pria; Cortelli, José Roberto; Costa, Fernando Oliveira; Cyrino, Renata Magalhães; Aquino, Davi Romeiro; Cogo-Müller, Karina; Miranda, Taís Browne; Moura, Sara Porto; Cortelli, Sheila Cavalca
2017-01-01
Abstract Objective: Single dose of systemic antibiotics and short-term use of mouthwashes reduce bacteremia. However, the effects of a single dose of preprocedural rinse are still controversial. This study evaluated, in periodontally diseased patients, the effects of a pre-procedural mouth rinse on induced bacteremia. Material and Methods: Systemically healthy individuals with gingivitis (n=27) or periodontitis (n = 27) were randomly allocated through a sealed envelope system to: 0.12% chlorhexidine pre-procedural rinse (13 gingivitis and 13 periodontitis patients) or no rinse before dental scaling (14 gingivitis and 15 periodontitis patients). Periodontal probing depth, clinical attachment level, plaque, and gingival indices were measured and subgingival samples were collected. Blood samples were collected before dental scaling, 2 and 6 minutes after scaling. Total bacterial load and levels of P. gingivalis were determined in oral and blood samples by real-time polymerase chain reaction, while aerobic and anaerobic counts were determined by culture in blood samples. The primary outcome was the antimicrobial effect of the pre-procedural rinse. Data was compared by Mann-Whitney and Signal tests (p<0.05). Results: In all sampling times, polymerase chain reaction revealed higher blood bacterial levels than culture (p<0.0001), while gingivitis patients presented lower bacterial levels in blood than periodontitis patients (p<0.0001). Individuals who experienced bacteremia showed worse mean clinical attachment level (3.4 mm vs. 1.1 mm) and more subgingival bacteria (p<0.005). The pre-procedural rinse did not reduce induced bacteremia. Conclusions: Bacteremia was influenced by periodontal parameters. In periodontally diseased patients, pre-procedural rinsing showed a discrete effect on bacteremia control. PMID:29211279
Leuthold, Luc Alexis; Heudi, Olivier; Déglon, Julien; Raccuglia, Marc; Augsburger, Marc; Picard, Franck; Kretz, Olivier; Thomas, Aurélien
2015-02-17
Hematocrit (Hct) is one of the most critical issues associated with the bioanalytical methods used for dried blood spot (DBS) sample analysis. Because Hct determines the viscosity of blood, it may affect the spreading of blood onto the filter paper. Hence, accurate quantitative data can only be obtained if the size of the paper filter extracted contains a fixed blood volume. We describe for the first time a microfluidic-based sampling procedure to enable accurate blood volume collection on commercially available DBS cards. The system allows the collection of a controlled volume of blood (e.g., 5 or 10 μL) within several seconds. Reproducibility of the sampling volume was examined in vivo on capillary blood by quantifying caffeine and paraxanthine on 5 different extracted DBS spots at two different time points and in vitro with a test compound, Mavoglurant, on 10 different spots at two Hct levels. Entire spots were extracted. In addition, the accuracy and precision (n = 3) data for the Mavoglurant quantitation in blood with Hct levels between 26% and 62% were evaluated. The interspot precision data were below 9.0%, which was equivalent to that of a manually spotted volume with a pipet. No Hct effect was observed in the quantitative results obtained for Hct levels from 26% to 62%. These data indicate that our microfluidic-based sampling procedure is accurate and precise and that the analysis of Mavoglurant is not affected by the Hct values. This provides a simple procedure for DBS sampling with a fixed volume of capillary blood, which could eliminate the recurrent Hct issue linked to DBS sample analysis.
Preparation of Plant Samples for Phytochemical Research and the Study of Their Biological Activities
USDA-ARS?s Scientific Manuscript database
Prior to investigating plant natural products for biologically active constituents, it is necessary to establish guidelines and procedures for carefully collecting, cataloging, and storing specimens. All field collections should begin with detailed records on location, which should include a list o...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bolivar, S.
This manual describes field procedures for the collection of stream-sediment and rock samples as part of the Mineral Resource Assessment of Costa Rica. It provides guidelines to be followed by personnel collecting, treating, or otherwise handling samples taken as part of this program. The objectives of the manual are to ensure that all samples are collected uniformly and consistent techniques are employed throughout the program. If this is done, the data from this study can be used to identify areas with potential for mineralization. This manual can also be used as a guideline for future geochemical sampling programs in Costamore » Rica.« less
The purpose of this SOP is to describe the methods used to collect indoor and outdoor air samples for the determination of selected volatile organic compounds (VOC's) using a pump to draw air through a Carbotrap Sampler. Volatile organic compounds (VOCs) present in the air are p...
STS-55 Payload Specialist Schlegel collects fungi sample at SL-D2 Rack 1
NASA Technical Reports Server (NTRS)
1993-01-01
STS-55 German Payload Specialist 2 Hans Schlegel, wearing lightweight headset, collects fungi sample while working at Spacelab Deutsche 2 (SL-D2) science module Rack 1 Work Bench. Schlegel is conducting these procedures in conjunction with the 'Fruiting Body Development of Fungi' experiment. Pieces of the experiment casing freefloat in the workstation.Schlegel represents the German Aerospace Research Establishment (DLR) on the 10-day spacelab mission.
Muliukin, A L; Demkina, E V; Manucharova, N A; Akimov, V N; Andersen, D; McKay, C; Gal'chenko, V F
2014-01-01
The heterotrophic mesophilic component was studied in microbial communities of the samples of frozen regolith collected from the glacier near Lake Untersee collected in 2011 during the joint Russian-American expedition to central Dronning Maud Land (Eastern Antarctica). Cultural techniques revealed high bacterial numbers in the samples. For enumeration of viable cells, the most probable numbers (MPN) method proved more efficient than plating on agar media. Fluorescent in situ hybridization with the relevant oligonucleotide probes revealed members of the groups Eubacteria (Actinobacteria, Firmicutes) and Archaea. Application of the methods of cell resuscitation, such as the use of diluted media and prevention of oxidative stress, did not result in a significant increase in the numbers of viable cells retrieved form subglacial sediment samples. Our previous investigations demonstrated the necessity for special procedures for efficient reactivation of the cells from microbial communities of preserved fossil soil and permafrost samples collected in the Arctic zone. The differences in response to the special resuscitation procedures may reflect the differences in the physiological and morphological state of bacterial cells in microbial communities subject to continuous or periodic low temperatures and dehydration.
This standard operating procedure (SOP) describes a new, rapid, and relatively inexpensive way to remove a precise area of paint from the substrate of building structures in preparation for quantitative analysis. This method has been applied successfully in the laboratory, as we...
Identity Orientation, Voice, and Judgments of Procedural Justice during Late Adolescence
ERIC Educational Resources Information Center
Fondacaro, Mark R.; Brank, Eve M.; Stuart, Jennifer; Villanueva-Abraham, Sara; Luescher, Jennifer; McNatt, Penny S.
2006-01-01
This study focused on the relationship between voice and judgments of procedural justice in a sample of older adolescents and examined potential moderating and mediating influences of identity orientation (personal, social, and collective) and negative emotional response. Participants read 1 of 2 different family conflict scenarios (voice and no…
Documentation for the 2003-04 Schools and Staffing Survey. NCES 2007-337
ERIC Educational Resources Information Center
Tourkin, Steven C.; Warner, Toni; Parmer, Randall; Cole, Cornette; Jackson, Betty; Zukerberg, Andrew; Cox, Shawna; Soderberg, Andrew
2007-01-01
This report serves as the survey documentation for the design and implementation of the 2003-04 Schools and Staffing Survey. Topics covered include the sample design, survey methodology, data collection procedures, data processing, response rates, imputation procedures, weighting and variance estimation, review of the quality of data, the types of…
Determination of Phenols and Trimethylamine in Industrial Effluents
NASA Technical Reports Server (NTRS)
Levaggi, D. A.; Feldstein, M.
1971-01-01
For regulatory purposes to control certain odorous compounds the analysis of phenols and trimethylamines in industrial effluents is necessary. The Bay Area Air Pollution Control District laboratory has been determining these gases by gas chromatographic techniques. The procedures for sample collection, preparation for analysis and determination are described in detail. Typical data from various sources showing the effect of proposed regulations is shown. Extensive sampling and usage of these procedures has shown them to be accurate, reliable and suitable to all types of source effluents.
23 CFR 1340.5 - Documentation requirements.
Code of Federal Regulations, 2010 CFR
2010-04-01
... STATE OBSERVATIONAL SURVEYS OF SEAT BELT USE § 1340.5 Documentation requirements. All sample design, data collection, and estimation procedures used in State surveys conducted in accordance with this part must be well documented. At a minimum, the documentation must: (a) For sample design— (1) Define all...
23 CFR 1340.5 - Documentation requirements.
Code of Federal Regulations, 2011 CFR
2011-04-01
... STATE OBSERVATIONAL SURVEYS OF SEAT BELT USE § 1340.5 Documentation requirements. All sample design, data collection, and estimation procedures used in State surveys conducted in accordance with this part must be well documented. At a minimum, the documentation must: (a) For sample design— (1) Define all...
NHEXAS PHASE I MARYLAND STUDY--LIST OF AVAILABLE DOCUMENTS: PROTOCOLS AND SOPS
This document lists available protocols and SOPs for the NHEXAS Phase I Maryland study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis and general laboratory procedures, (3) Data Analysis Proced...
Failure mode analysis in adrenal vein sampling: a single-center experience.
Trerotola, Scott O; Asmar, Melissa; Yan, Yan; Fraker, Douglas L; Cohen, Debbie L
2014-10-01
To analyze failure modes in a high-volume adrenal vein sampling (AVS) practice in an effort to identify preventable causes of nondiagnostic sampling. A retrospective database was constructed containing 343 AVS procedures performed over a 10-year period. Each nondiagnostic AVS procedure was reviewed for failure mode and correlated with results of any repeat AVS. Data collected included selectivity index, lateralization index, adrenalectomy outcomes if performed, and details of AVS procedure. All AVS procedures were performed after cosyntropin stimulation, using sequential technique. AVS was nondiagnostic in 12 of 343 (3.5%) primary procedures and 2 secondary procedures. Failure was right-sided in 8 (57%) procedures, left-sided in 4 (29%) procedures, bilateral in 1 procedure, and neither in 1 procedure (laboratory error). Failure modes included diluted sample from correctly identified vein (n = 7 [50%]; 3 right and 4 left), vessel misidentified as adrenal vein (n = 3 [21%]; all right), failure to locate an adrenal vein (n = 2 [14%]; both right), cosyntropin stimulation failure (n = 1 [7%]; diagnostic by nonstimulated criteria), and laboratory error (n = 1 [7%]; specimen loss). A second AVS procedure was diagnostic in three of five cases (60%), and a third AVS procedure was diagnostic in one of one case (100%). Among the eight patients in whom AVS ultimately was not diagnostic, four underwent adrenalectomy based on diluted AVS samples, and one underwent adrenalectomy based on imaging; all five experienced improvement in aldosteronism. A substantial percentage of AVS failures occur on the left, all related to dilution. Even when technically nondiagnostic per strict criteria, some "failed" AVS procedures may be sufficient to guide therapy. Repeat AVS has a good yield. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.
Arnold, Myrtha; Langhans, Wolfgang
2010-04-19
Blood is routinely sampled from laboratory animals in biomedical research, and many of the commonly applied sampling techniques require anesthesia. Acute effects of many sampling and anesthesia procedures may confound the results, but those effects are incompletely characterized. We here compare the effects of four common anesthesia procedures (inhalation anesthesia with ether (EA) or isoflurane (IA) and intraperitoneal injection anesthesia with xylazin/ketamine (XKA) or medetomidine/midazolam/fentanyl (MMFA)) on plasma concentrations of glucose, lactate, non-esterified fatty acids (NEFAs), and corticosterone in blood obtained from a previously implanted jugular vein (JV) catheter with the effect of JV blood sampling from non-anesthetized, freely-moving rats (JV-NA). Also, we included in the comparison two other blood sampling procedures usually performed without anesthesia (NA), i.e., puncture of the saphenic vein (SV) and tail incision (TI). Whereas the control procedure (JV-NA) did not significantly affect any of the target parameters, plasma glucose increased from 14 (JV-IA) to 44 (JV-MMFA) % (all Ps=0.05 when compared with the control procedure) in all blood samples collected in anesthesia and was 12 and 14% lower (both Ps<0.05) in SV-NA and TI-NA samples, respectively. Plasma lactate increased from 74 (JV-IA) to 226% (SV-NA) (all Ps<0.05) with all sampling and anesthesia procedures except for JV-XKA and JV-MMF. Plasma NEFAs increased to 52% (P<0.05) with the TI-NA procedure and appeared to decrease with the JV-IA and JV-MMFA procedures (both Ps>0.05). Finally, only the JV-EA and the JV-MMFA procedures increased plasma corticosterone (+525 and +353%, respectively, both Ps< 0.05). The JV-IA and JV-XKA procedures appeared to increase it as well, but these differences did not reach statistical significance. Thus, anesthesia and blood sampling procedures can have profound acute effects on plasma metabolite and hormone concentrations. This must be considered for the design and interpretation of blood sampling experiments in laboratory animals. (c) 2010. Published by Elsevier Inc.
Von Guerard, Paul; Weiss, W.B.
1995-01-01
The U.S. Environmental Protection Agency requires that municipalities that have a population of 100,000 or greater obtain National Pollutant Discharge Elimination System permits to characterize the quality of their storm runoff. In 1992, the U.S. Geological Survey, in cooperation with the Colorado Springs City Engineering Division, began a study to characterize the water quality of storm runoff and to evaluate procedures for the estimation of storm-runoff loads, volume and event-mean concentrations for selected properties and constituents. Precipitation, streamflow, and water-quality data were collected during 1992 at five sites in Colorado Springs. Thirty-five samples were collected, seven at each of the five sites. At each site, three samples were collected for permitting purposes; two of the samples were collected during rainfall runoff, and one sample was collected during snowmelt runoff. Four additional samples were collected at each site to obtain a large enough sample size to estimate storm-runoff loads, volume, and event-mean concentrations for selected properties and constituents using linear-regression procedures developed using data from the Nationwide Urban Runoff Program (NURP). Storm-water samples were analyzed for as many as 186 properties and constituents. The constituents measured include total-recoverable metals, vola-tile-organic compounds, acid-base/neutral organic compounds, and pesticides. Storm runoff sampled had large concentrations of chemical oxygen demand and 5-day biochemical oxygen demand. Chemical oxygen demand ranged from 100 to 830 milligrams per liter, and 5.-day biochemical oxygen demand ranged from 14 to 260 milligrams per liter. Total-organic carbon concentrations ranged from 18 to 240 milligrams per liter. The total-recoverable metals lead and zinc had the largest concentrations of the total-recoverable metals analyzed. Concentrations of lead ranged from 23 to 350 micrograms per liter, and concentrations of zinc ranged from 110 to 1,400 micrograms per liter. The data for 30 storms representing rainfall runoff from 5 drainage basins were used to develop single-storm local-regression models. The response variables, storm-runoff loads, volume, and event-mean concentrations were modeled using explanatory variables for climatic, physical, and land-use characteristics. The r2 for models that use ordinary least-squares regression ranged from 0.57 to 0.86 for storm-runoff loads and volume and from 0.25 to 0.63 for storm-runoff event-mean concentrations. Except for cadmium, standard errors of estimate ranged from 43 to 115 percent for storm- runoff loads and volume and from 35 to 66 percent for storm-runoff event-mean concentrations. Eleven of the 30 concentrations collected during rainfall runoff for total-recoverable cadmium were censored (less than) concentrations. Ordinary least-squares regression should not be used with censored data; however, censored data can be included with uncensored data using tobit regression. Standard errors of estimate for storm-runoff load and event-mean concentration for total-recoverable cadmium, computed using tobit regression, are 247 and 171 percent. Estimates from single-storm regional-regression models, developed from the Nationwide Urban Runoff Program data base, were compared with observed storm-runoff loads, volume, and event-mean concentrations determined from samples collected in the study area. Single-storm regional-regression models tended to overestimate storm-runoff loads, volume, and event-mean con-centrations. Therefore, single-storm local- and regional-regression models were combined using model-adjustment procedures to take advantage of the strengths of both models while minimizing the deficiencies of each model. Procedures were used to develop single-stormregression equations that were adjusted using local data and estimates from single-storm regional-regression equations. Single-storm regression models developed using model- adjustment proce
Report on the Directory of Library Collections in Ethnocultural Organizations in Canada: Ontario.
ERIC Educational Resources Information Center
Aliferis, Isabella; Wierucki, Karen
This report discusses the methodology, problems, follow-up procedures, recommendations, and benefits involved in the compilation of a directory which will identify library collections held by ethnocultural clubs, federations, organizations, community centers, and language schools in Canada. Appendices contain samples of a form letter,…
Method T)-15 describes procedures for for preparation and analysis of air samples containing volatile organic compounds collected in specially-prepared canisters, using gas chromatography-mass spectrometry.
Puls, Robert W.; Eychaner, James H.; Powell, Robert M.
1996-01-01
Investigations at Pinal Creek, Arizona, evaluated routine sampling procedures for determination of aqueous inorganic geochemistry and assessment of contaminant transport by colloidal mobility. Sampling variables included pump type and flow rate, collection under air or nitrogen, and filter pore diameter. During well purging and sample collection, suspended particle size and number as well as dissolved oxygen, temperature, specific conductance, pH, and redox potential were monitored. Laboratory analyses of both unfiltered samples and the filtrates were performed by inductively coupled argon plasma, atomic absorption with graphite furnace, and ion chromatography. Scanning electron microscopy with Energy Dispersive X-ray was also used for analysis of filter particulates. Suspended particle counts consistently required approximately twice as long as the other field-monitored indicators to stabilize. High-flow-rate pumps entrained normally nonmobile particles. Difference in elemental concentrations using different filter-pore sizes were generally not large with only two wells having differences greater than 10 percent in most wells. Similar differences (>10%) were observed for some wells when samples were collected under nitrogen rather than in air. Fe2+/Fe3+ ratios for air-collected samples were smaller than for samples collected under a nitrogen atmosphere, reflecting sampling-induced oxidation.
Zhang, Fengrui; Adeola, Olayiwola
2017-12-01
Sound feed formulation is dependent upon precise evaluation of energy and nutrients values in feed ingredients. Hence the methodology to determine the digestibility of energy and nutrients in feedstuffs should be chosen carefully before conducting experiments. The direct and difference procedures are widely used to determine the digestibility of energy and nutrients in feedstuffs. The direct procedure is normally considered when the test feedstuff can be formulated as the sole source of the component of interest in the test diet. However, in some cases where test ingredients can only be formulated to replace a portion of the basal diet to provide the component of interest, the difference procedure can be applied to get equally robust values. Based on components of interest, ileal digesta or feces can be collected, and different sample collection processes can be used. For example, for amino acids (AA), to avoid the interference of fermentation in the hind gut, ileal digesta samples are collected to determine the ileal digestibility and simple T-cannula and index method are commonly used techniques for AA digestibility analysis. For energy, phosphorus, and calcium, normally fecal samples will be collected to determine the total tract digestibility, and therefore the total collection method is recommended to obtain more accurate estimates. Concerns with the use of apparent digestibility values include different estimated values from different inclusion level and non-additivity in mixtures of feed ingredients. These concerns can be overcome by using standardized digestibility, or true digestibility, by correcting endogenous losses of components from apparent digestibility values. In this review, methodologies used to determine energy and nutrients digestibility in pigs are discussed. It is suggested that the methodology should be carefully selected based on the component of interest, feed ingredients, and available experimental facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Stripped Resin and Process Wastewater 9 Table 9 to Subpart HHHHHHH of Part 63 Protection of Environment... Wastewater For demonstrating . . . For the following emission points and types of processes . . . Collect.... Each process wastewater stream 3. Initial compliance N/A 1 grab sample 1 grab sample. 4. Continuous...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Stripped Resin and Process Wastewater 9 Table 9 to Subpart HHHHHHH of Part 63 Protection of Environment... Wastewater For demonstrating . . . For the following emission points and types of processes . . . Collect.... Each process wastewater stream 3. Initial compliance N/A 1 grab sample 1 grab sample. 4. Continuous...
Cantú, Ricardo; Shoemaker, Jody A; Kelty, Catherine A; Wymer, Larry J; Behymer, Thomas D; Dufour, Alfred P; Magnuson, Matthew L
2017-08-22
The use of cyanuric acid as a biomarker for ingestion of swimming pool water may lead to quantitative knowledge of the volume of water ingested during swimming, contributing to a better understanding of disease resulting from ingestion of environmental contaminants. When swimming pool water containing chlorinated cyanurates is inadvertently ingested, cyanuric acid is excreted quantitatively within 24 h as a urinary biomarker of ingestion. Because the volume of water ingested can be quantitatively estimated by calculation from the concentration of cyanuric acid in 24 h urine samples, a procedure for preservation, cleanup, and analysis of cyanuric acid was developed to meet the logistical demands of large scale studies. From a practical stand point, urine collected from swimmers cannot be analyzed immediately, given requirements of sample collection, shipping, handling, etc. Thus, to maintain quality control to allow confidence in the results, it is necessary to preserve the samples in a manner that ensures as quantitative analysis as possible. The preservation and clean-up of cyanuric acid in urine is complicated because typical approaches often are incompatible with the keto-enol tautomerization of cyanuric acid, interfering with cyanuric acid sample preparation, chromatography, and detection. Therefore, this paper presents a novel integration of sample preservation, clean-up, chromatography, and detection to determine cyanuric acid in 24 h urine samples. Fortification of urine with cyanuric acid (0.3-3.0 mg/L) demonstrated accuracy (86-93% recovery) and high reproducibility (RSD < 7%). Holding time studies in unpreserved urine suggested sufficient cyanuric acid stability for sample collection procedures, while longer holding times suggested instability of the unpreserved urine. Preserved urine exhibited a loss of around 0.5% after 22 days at refrigerated storage conditions of 4 °C. Published by Elsevier B.V.
Carlsson, Sten; Olsson, Robert; Lindkvist, Irene; Beck, Olof
2015-04-01
Exhaled breath has recently been identified as a possible matrix for drug testing. This study explored the potential of this new method for compliance monitoring of patients being treated for dependence disorders. Outpatients in treatment programs were recruited for this study. Urine was collected as part of clinical routine and a breath sample was collected in parallel together with a questionnaire about their views of the testing procedure. Urine was analyzed for amphetamines, benzodiazepines, cannabis, cocaine, buprenorphine, methadone and opiates using CEDIA immunochemical screening and mass spectrometry confirmation. The exhaled breath was collected using the SensAbues device and analyzed by mass spectrometry for amphetamine, methamphetamine, diazepam, oxazepam, tetrahydrocannabinol, cocaine, benzoylecgonine, buprenorphine, methadone, morphine, codeine and 6-acetylmorphine. A total of 122 cases with parallel urine and breath samples were collected; 34 of these were negative both in urine and breath. Out of 88 cases with positive urine samples 51 (58%) were also positive in breath. Among the patients on methadone treatment, all were positive for methadone in urine and 83% were positive in breath. Among patients in treatment with buprenorphine, 92% were positive in urine and among those 80% were also positive in breath. The questionnaire response documented that in general, patients accepted drug testing well and that the breath sampling procedure was preferred. Compliance testing for the intake of prescribed and unprescribed drugs among patients in treatment for dependence disorders using the exhaled breath sampling technique is a viable method and deserves future attention.
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2009-01-01
The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's Lab Master data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality control samples analyzed from July 2005 through June 2007. Results for the quality-control samples for 19 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: total aluminum, calcium, magnesium, nitrate (colorimetric method), potassium, silicon, sodium, and sulfate. Eight of the analytical procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits; these procedures were: total aluminum, calcium, dissolved organic carbon, chloride, nitrate (ion chromatograph), potassium, silicon, and sulfate. The magnesium and pH procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The acid-neutralizing capacity, total monomeric aluminum, nitrite, and specific conductance procedures were biased for the high-concentration and low-concentration samples, but were within control limits. Results from the filter-blank and analytical-blank analyses indicated that the procedures for 16 of 17 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 18 of the 21 analytes. At least 93 percent of the samples met data-quality objectives for all analytes except acid-neutralizing capacity (85 percent of samples met objectives), total monomeric aluminum (83 percent of samples met objectives), total aluminum (85 percent of samples met objectives), and chloride (85 percent of samples met objectives). The ammonium and total dissolved nitrogen did not meet the data-quality objectives. Results of the USGS interlaboratory Standard Reference Sample (SRS) Project met the Troy Laboratory data-quality objectives for 87 percent of the samples analyzed. The P-sample (low-ionic-strength constituents) analysis had two outliers each in two studies. The T-sample (trace constituents) analysis and the N-sample (nutrient constituents) analysis had one outlier each in two studies. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 85 percent of the samples met data-quality objectives for 11 of the 14 analytes; the exceptions were acid-neutralizing capacity, total aluminum and ammonium. Data-quality objectives were not met in 41 percent of samples analyzed for acid-neutralizing capacity, 50 percent of samples analyzed for total aluminum, and 44 percent of samples analyzed for ammonium. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 86 percent of the samples analyzed for calcium, magnesium, pH, potassium, and sodium. Data-quality objectives were met by 76 percent of the samples analyzed for chloride, 80 percent of the samples analyzed for specific conductance, and 77 percent of the samples analyzed for sulfate.
Terrestrial contamination in Apollo lunar samples.
NASA Technical Reports Server (NTRS)
Flory, D. A.; Simoneit, B. R.
1972-01-01
The contamination prevention procedures adopted for controlling the collection, processing, and analysis of the Apollo lunar samples in order to keep them free of significant levels of terrestrial organic matter are described. The organic contaminants actually found in the samples by the various investigators are summarized. It is shown that the program succeeded in providing investigators with samples containing less than 0.1 ppm total contamination.
Petersen, James C.; Justus, B.G.; Dodd, H.R.; Bowles, D.E.; Morrison, L.W.; Williams, M.H.; Rowell, G.A.
2008-01-01
Buffalo National River located in north-central Arkansas, and Ozark National Scenic Riverways, located in southeastern Missouri, are the two largest units of the National Park Service in the Ozark Plateaus physiographic province. The purpose of this report is to provide a protocol that will be used by the National Park Service to sample fish communities and collect related water-quality, habitat, and stream discharge data of Buffalo National River and Ozark National Scenic Riverways to meet inventory and long-term monitoring objectives. The protocol includes (1) a protocol narrative, (2) several standard operating procedures, and (3) supplemental information helpful for implementation of the protocol. The protocol narrative provides background information about the protocol such as the rationale of why a particular resource or resource issue was selected for monitoring, information concerning the resource or resource issue of interest, a description of how monitoring results will inform management decisions, and a discussion of the linkages between this and other monitoring projects. The standard operating procedures cover preparation, training, reach selection, water-quality sampling, fish community sampling, physical habitat collection, measuring stream discharge, equipment maintenance and storage, data management and analysis, reporting, and protocol revision procedures. Much of the information in the standard operating procedures was gathered from existing protocols of the U.S. Geological Survey National Water Quality Assessment program or other sources. Supplemental information that would be helpful for implementing the protocol is included. This information includes information on fish species known or suspected to occur in the parks, sample sites, sample design, fish species traits, index of biotic integrity metrics, sampling equipment, and field forms.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ward, T.E.; Hartman, M.W.; Olin, R.C.
1989-06-01
Quality-assurance procedures are contained in this comprehensive document intended to be used as an aid for wood-heater manufacturers and testing laboratories in performing particulate matter sampling of wood heaters according to EPA protocol, Method 5G. These procedures may be used in research and development, and as an aid in auditing and certification testing. A detailed, step-by-step quality assurance guide is provided to aid in the procurement and assembly of testing apparatus, to clearly describe the procedures, and to facilitate data collection and reporting. Suggested data sheets are supplied that can be used as an aid for both recordkeeping and certificationmore » applications. Throughout the document, activity matrices are provided to serve as a summary reference. Checklists are also supplied that can be used by testing personnel. Finally, for the purposes of ensuring data quality, procedures are outlined for apparatus operation, maintenance, and traceability. These procedures combined with the detailed description of the sampling and analysis protocol will help ensure the accuracy and reliability of Method 5G emission-testing results.« less
Velásquez, A V; da Silva, G G; Sousa, D O; Oliveira, C A; Martins, C M M R; Dos Santos, P P M; Balieiro, J C C; Rennó, F P; Fukushima, R S
2018-04-18
Feed intake assessment is a valuable tool for herd management decisions. The use of markers, either internal or external, is currently the most used technique for estimating feed intake in production animals. The experiment used 10 multiparous Holstein cows fed a corn silage-based diet, with 55:45 forage-to-concentrate ratio, the average fecal recovery (FR) of TiO 2 was higher than FR of Cr 2 O 3 , and both FR were more than unity. With internal markers, acetyl bromide lignin and cutin FR were lower than unity, and average FR for indigestible neutral detergent fiber (iNDF) and indigestible acid detergent fiber (iADF) was 1.5. The FR was unaffected by the fecal sampling procedure and appears to be an intrinsic property of each molecule and how it interacts with digesta. Of the 2 external markers, only Cr 2 O 3 produced accurate fecal output (FO) estimates and the same happened to dry matter digestibility (DMD) when iNDF and iADF were used. Estimates for DMD and FO were affected by sampling procedure; 72-h bulk [sub-sample from total feces collection (TFC)] sampling consistently produced accurate results. The grab (sub-samples taken at specific times during the day) sampling procedures were accurate when using either of the indigestible fibers (iNDF or iADF) to estimate DMD. However, grab sampling procedures can only be recommended when concomitant TFC is performed on at least one animal per treatment to determine FR. Under these conditions, Cr 2 O 3 is a suitable marker for estimating FO, and iNDF and iADF are adequate for estimating DMD. Moreover, the Cr 2 O 3 +iADF marker pair produces accurate dry matter intake estimates and deserves further attention in ruminant nutrition studies. The method of dosing the external markers is extremely important and greatly affects and determines results. Whichever the method, it must allow the animals to display normal feeding behavior and not affect performance. The grab sampling procedures can replace TFC (once FR is established), which may open new possibilities for pasture-based or collectively housed animals. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Methods for collection and analysis of geopressured geothermal and oil field waters
Lico, Michael S.; Kharaka, Yousif K.; Carothers, William W.; Wright, Victoria A.
1982-01-01
Present methods are described for the collection, preservation, and chemical analysis of waters produced from geopressured geothermal and petroleum wells. Detailed procedures for collection include precautions and equipment necessary to ensure that the sample is representative of the water produced. Procedures for sample preservation include filtration, acidification, dilution for silica, methyl isobutyl ketone (MIBK) extraction of aluminum, addition of potassium permanganate to preserve mercury, and precipitation of carbonate species as strontium carbonate for stable carbon isotopes and total dissolved carbonate analysis. Characteristics determined at the well site are sulfide, pH, ammonia, and conductivity. Laboratory procedures are given for the analysis of lithium, sodium, potassium, rubidium, cesium, magnesium, calcium, strontium, barium, iron, manganese, zinc, lead, aluminum, .and mercury by atomic absorption and flame emission spectroscopy. Chloride is determined by silver nitrate titration and fluoride by ion-specific electrode. Bromide and iodide concentrations are determined by the hypochlorite oxidation method. Sulfate is analyzed by titration using barium chloride with thorin indicator after pretreatment with alumina. Boron and silica are determined colorimetrically by the carmine and molybdate-blue methods, respectively. Aliphatic acid anions (C2 through C5) are determined by gas chromatography after separation and concentration in a chloroform-butanol mixture.
Protocol for monitoring metals in Ozark National Scenic Riverways, Missouri: Version 1.0
Schmitt, Christopher J.; Brumbaugh, William G.; Besser, John M.; Hinck, Jo Ellen; Bowles, David E.; Morrison, Lloyd W.; Williams, Michael H.
2008-01-01
The National Park Service is developing a monitoring plan for the Ozark National Scenic Riverways in southeastern Missouri. Because of concerns about the release of lead, zinc, and other metals from lead-zinc mining to streams, the monitoring plan will include mining-related metals. After considering a variety of alternatives, the plan will consist of measuring the concentrations of cadmium, cobalt, lead, nickel, and zinc in composite samples of crayfish (Orconectes luteus or alternate species) and Asian clam (Corbicula fluminea) collected periodically from selected sites. This document, which comprises a protocol narrative and supporting standard operating procedures, describes the methods to be employed prior to, during, and after collection of the organisms, along with procedures for their chemical analysis and quality assurance; statistical analysis, interpretation, and reporting of the data; and for modifying the protocol narrative and supporting standard operating procedures. A list of supplies and equipment, data forms, and sample labels are also included. An example based on data from a pilot study is presented.
People's Need for Additional Job Training: Development and Evaluation of an Assessment Procedure.
ERIC Educational Resources Information Center
Copa, George H.; Maurice, Clyde F.
A procedure was developed and evaluated for assessing the self-perceived educational needs of people as one input to the process of planning, approving, and implementing relevant educational programs. The method of data collection involved selecting samples of people by randomly selecting households in a given geographic area, and then contacting…
ERIC Educational Resources Information Center
Bachman, Jerald G.; Johnston, Lloyd D.; O'Malley, Patrick M.; Schulenberg, John E.
2006-01-01
This occasional paper updates and extends earlier papers in the Monitoring the Future project. It provides a detailed description of the project's design, including sampling design, data collection procedures, measurement content, and questionnaire format. It attempts to include sufficient information for others who wish to evaluate the results,…
The purpose of this SOP is to describe the in-field use of the modified Air Sentinel. Samples collected with this Hi-Vol instrument were analyzed for atmospheric concentrations of target metals. This procedure was followed to ensure consistent data retrieval of air and dust ana...
NASA Technical Reports Server (NTRS)
McCubbin, F. M.; Allton, J. H.; Barnes, J. J.; Boyce, J. W.; Burton, A. S.; Draper, D. S.; Evans, C. A.; Fries, M. D.; Jones, J. H.; Keller, L. P.;
2017-01-01
The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. JSC presently curates 9 different astromaterials collections: (1) Apollo samples, (2) LUNA samples, (3) Antarctic meteorites, (4) Cosmic dust particles, (5) Microparticle Impact Collection [formerly called Space Exposed Hardware], (6) Genesis solar wind, (7) Star-dust comet Wild-2 particles, (8) Stardust interstellar particles, and (9) Hayabusa asteroid Itokawa particles. In addition, the next missions bringing carbonaceous asteroid samples to JSC are Hayabusa 2/ asteroid Ryugu and OSIRIS-Rex/ asteroid Bennu, in 2021 and 2023, respectively. The Hayabusa 2 samples are provided as part of an international agreement with JAXA. The NASA Curation Office plans for the requirements of future collections in an "Advanced Curation" program. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of collections as envisioned by NASA exploration goals. Here we review the science value and sample curation needs of some potential targets for sample return missions over the next 35 years.
Mechanic, Leah; Mendez, Armando; Merrill, Lori; Rogers, John; Layton, Marnie; Todd, Deborah; Varanasi, Arti; O’Brien, Barbara; Meyer, William A.; Zhang, Ming; Schleicher, Rosemary L.; Moye, Jack
2014-01-01
BACKGROUND Preanalytical conditions encountered during collection, processing, and storage of biospecimens may influence laboratory results. The National Children’s Study (NCS) is a planned prospective cohort study of 100,000 families to examine the influence of a wide variety of exposures on child health. In developing biospecimen collection, processing, and storage procedures for the NCS, we identified several analytes of different biochemical categories for which it was unclear to what extent deviations from NCS procedures could influence measurement results. METHODS A pilot study was performed to examine effects of preanalytic sample handling conditions (delays in centrifugation, freezing delays, delays in separation from cells, additive delay, and tube type) on concentrations of eight different analytes. 2,825 measurements were made to assess 15 unique combinations of analyte and handling conditions in blood collected from 151 women of childbearing age (≥20 individuals per handling condition). RESULTS The majority of analytes were stable under the conditions evaluated. However, levels of plasma interleukin-6 and serum insulin were decreased in response to sample centrifugation delays of up to 5.5 hours post collection (P<0.0001). In addition, delays in freezing centrifuged plasma samples (comparing 24, 48 and 72 hours to immediate freezing) resulted in increased levels of adrenocorticotropic hormone (P=0.0014). CONCLUSIONS Determining stability of proposed analytes in response to preanalytical conditions and handling helps to ensure high-quality specimens for study now and in the future. The results inform development of procedures, plans for measurement of analytes, and interpretation of laboratory results. PMID:23924524
77 FR 15092 - U.S. Energy Information Administration; Proposed Agency Information Collection
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-14
... conducted under this clearance will generally be methodological studies of 500 cases or less. The samples... conducted under this clearance will generally be methodological studies of 500 cases or less, but will... the methodological design, sampling procedures (where possible) and questionnaires of the full scale...
Source Testing for Particulate Matter.
ERIC Educational Resources Information Center
DeVorkin, Howard
Developed for presentation at the 12th Conference on Methods in Air Pollution and Industrial Hygiene Studies, University of Southern California, April, 1971, this outline covers procedures for the testing of particulate matter. These are: (1) basic requirements, (2) information required, (3) collection of samples, (4) processing of samples, (5)…
40 CFR 86.135-90 - Dynamometer procedure.
Code of Federal Regulations, 2014 CFR
2014-07-01
... petroleum gas-fueled Otto-cycle vehicles, the composite samples collected in bags are analyzed for THC, CO..., liquefied petroleum gas-fueled and methanol-fueled diesel-cycle vehicles), THC is sampled and analyzed... analyzed for THC, CO, CO2, CH4, and NOX. (3) For natural gas-fueled, liquefied petroleum gas-fueled and...
CTEPP STANDARD OPERATING PROCEDURE FOR VIDEOTAPING CHILD ACTIVITIES (SOP-2.23)
This SOP describes the method for videotaping a preschool child at a home. The CTEPP main study will collect multimedia samples and questionnaire data at the homes of participants (adults and children) during 48-hr sampling periods. Videotaping the activities of 10% of these chi...
Soils element activities for the period October 1973--September 1974
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fowler, E.B.; Essington, E.H.; White, M.G.
Soils Element activities were conducted on behalf of the U. S. Atomic Energy Commission's Nevada Applied Ecology Group (NAEG) program to provide source term information for the other program elements and maintain continuous cognizance of program requirements for sampling, sample preparation, and analysis. Activities included presentation of papers; participation in workshops; analysis of soil, vegetation, and animal tissue samples for $sup 238$Pu, $sup 239-240$Pu, $sup 241$Am, $sup 137$Cs, $sup 60$Co, and gamma scan for routine and laboratory quality control purposes; preparation and analysis of animal tissue samples for NAEG laboratory certification; studies on a number of analytical, sample preparation, andmore » sample collection procedures; and contributions to the evaluation of procedures for calculation of specialized counting statistics. (auth)« less
Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew
2007-01-01
The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.
Rapid microfluidic analysis of a Y-STR multiplex for screening of forensic samples.
Gibson-Daw, Georgiana; Albani, Patricia; Gassmann, Marcus; McCord, Bruce
2017-02-01
In this paper, we demonstrate a rapid analysis procedure for use with a small set of rapidly mutating Y chromosomal short tandem repeat (Y-STR) loci that combines both rapid polymerase chain reaction (PCR) and microfluidic separation elements. The procedure involves a high-speed polymerase and a rapid cycling protocol to permit PCR amplification in 16 min. The resultant amplified sample is next analysed using a short 1.8-cm microfluidic electrophoresis system that permits a four-locus Y-STR genotype to be produced in 80 s. The entire procedure takes less than 25 min from sample collection to result. This paper describes the rapid amplification protocol as well as studies of the reproducibility and sensitivity of the procedure and its optimisation. The amplification process utilises a small high-speed thermocycler, microfluidic device and compact laptop, making it portable and potentially useful for rapid, inexpensive on-site genotyping. The four loci used for the multiplex were selected due to their rapid mutation rates and should proved useful in preliminary screening of samples and suspects. Overall, this technique provides a method for rapid sample screening of suspect and crime scene samples in forensic casework. Graphical abstract ᅟ.
Száková, J; Tlustos, P; Goessler, W; Frková, Z; Najmanová, J
2009-12-30
The effect of soil extraction procedures and/or sample pretreatment (drying, freezing of the soil sample) on the extractability of arsenic and its compounds was tested. In the first part, five extraction procedures were compared with following order of extractable arsenic portions: 2M HNO(3)>0.43 M CH(3)COOH>or=0.05 M EDTA>or=Mehlich III (0.2M CH(3)COOH+0.25 M NH(4)NO(3)+0.013 M HNO(3)+0.015 M NH(4)F+0.001 M EDTA) extraction>water). Additionally, two methods of soil solution sampling were compared, centrifugation of saturated soil and the use of suction cups. The results showed that different sample pretreatments including soil solution sampling could lead to different absolute values of mobile arsenic content in soils. However, the interpretation of the data can lead to similar conclusions as apparent from the comparison of the soil solution sampling methods (r=0.79). For determination of arsenic compounds mild extraction procedures (0.05 M (NH(4))(2)SO(4), 0.01 M CaCl(2), and water) and soil solution sampling using suction cups were compared. Regarding the real soil conditions the extraction of fresh samples and/or in situ collection of soil solution are preferred among the sample pretreatments and/or soil extraction procedures. However, chemical stabilization of the solutions should be allowed and included in the analytical procedures for determination of individual arsenic compounds.
About Rubella (German Measles, Three-Day Measles)
... Professionals Pregnancy and Rubella Rubella Vaccination Travelers’ Health Information on Rubella Laboratory Testing CDC Laboratory Testing & Procedures Serology RNA Detection Genetic Analysis Specimen Collection, Storage, & Shipment Sample Submission Q&A ...
Rubella (German Measles, Three-Day Measles) Photos
... Professionals Pregnancy and Rubella Rubella Vaccination Travelers’ Health Information on Rubella Laboratory Testing CDC Laboratory Testing & Procedures Serology RNA Detection Genetic Analysis Specimen Collection, Storage, & Shipment Sample Submission Q&A ...
Rural Youth Education Project: Third Wave
ERIC Educational Resources Information Center
Center for Rural Pennsylvania, 2010
2010-01-01
This study is designed to include four waves of data collection, conducted approximately every other year, beginning in 2004 and continuing through 2011. This report briefly describes the procedures used for the third wave of data collection, completed in 2008-2009, and the results from a sample of Pennsylvania's rural 11th grade youth and youth…
77 FR 58383 - Agency Information Collection Activities: Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-20
...) The Kids' Inpatient Database (KID) is the only all-payer inpatient care database for children in the United States. The KID was specifically designed to permit researchers to study a broad range of conditions and procedures related to child health issues. The KID contains a sample of over 3 million...
ERIC Educational Resources Information Center
Keeling, Charles D.
This booklet is one of a series intended to provide explicit instructions for the collection of oceanographic data and samples at sea. The methods and procedures described have been used by the Scripps Institution of Oceanography and found reliable and up-to-date. Instructions are given for taking air samples on board ship to determine the…
40 CFR 86.159-08 - Exhaust emission test procedures for US06 emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... gasoline-fueled Otto-cycle vehicles, the composite samples collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2...
40 CFR 86.159-08 - Exhaust emission test procedures for US06 emissions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... gasoline-fueled Otto-cycle vehicles, the composite samples collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2...
40 CFR 86.159-08 - Exhaust emission test procedures for US06 emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... gasoline-fueled Otto-cycle vehicles, the composite samples collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2...
40 CFR 86.159-08 - Exhaust emission test procedures for US06 emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... gasoline-fueled Otto-cycle vehicles, the composite samples collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2...
40 CFR 86.159-08 - Exhaust emission test procedures for US06 emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... gasoline-fueled Otto-cycle vehicles, the composite samples collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2...
Significance of biological resource collection and tumor tissue bank creation.
Yu, Ying-Yan; Zhu, Zheng-Gang
2010-01-15
Progress in the molecular oncology of gastrointestinal carcinomas depends on high quality cancer tissues for research. Recent acceleration on new technological platforms as well as the "omics" revolution increases the demands on tissues and peripheral blood for research at the DNA, mRNA and protein levels. Tissue bank creation emerges as a priority. Tumor tissue banks are facilities that are organized to collect, store and distribute samples of tumor and normal tissue for further use in basic and translational cancer research. The samples are generally obtained immediately after excision, prior to fixation, to ensure optimal preservation of proteins and nucleic acids. It is possible for surgeons or pathologists to collect fresh tissue prospectively during their routine dissection procedures. Most tissue banks are "project-driven" tumor banks, which are specialized collections of tumor samples on which their research is based. Systematic collection of all available tumor tissue is much rarer. High quality tissue banks need the collaboration of clinicians and basic scientists, but also the informed consent of patients and ethical approval. Through the standard operation procedure, snap frozen fresh tissue collection, storage and quality control for cryopreserved tissues are the pivotal factors on tissue bank construction and maintaining. The purpose of the tissue bank creation is enhancing the quality and speed on both the basic and translational research on gastrointestinal cancer. The quality assurance and quality control are handled based on reviewing HE staining slides or touch imprint cytology by pathologists.
A laboratory procedure for measuring and georeferencing soil colour
NASA Astrophysics Data System (ADS)
Marques-Mateu, A.; Balaguer-Puig, M.; Moreno-Ramon, H.; Ibanez-Asensio, S.
2015-04-01
Remote sensing and geospatial applications very often require ground truth data to assess outcomes from spatial analyses or environmental models. Those data sets, however, may be difficult to collect in proper format or may even be unavailable. In the particular case of soil colour the collection of reliable ground data can be cumbersome due to measuring methods, colour communication issues, and other practical factors which lead to a lack of standard procedure for soil colour measurement and georeferencing. In this paper we present a laboratory procedure that provides colour coordinates of georeferenced soil samples which become useful in later processing stages of soil mapping and classification from digital images. The procedure requires a laboratory setup consisting of a light booth and a trichromatic colorimeter, together with a computer program that performs colour measurement, storage, and colour space transformation tasks. Measurement tasks are automated by means of specific data logging routines which allow storing recorded colour data in a spatial format. A key feature of the system is the ability of transforming between physically-based colour spaces and the Munsell system which is still the standard in soil science. The working scheme pursues the automation of routine tasks whenever possible and the avoidance of input mistakes by means of a convenient layout of the user interface. The program can readily manage colour and coordinate data sets which eventually allow creating spatial data sets. All the tasks regarding data joining between colorimeter measurements and samples locations are executed by the software in the background, allowing users to concentrate on samples processing. As a result, we obtained a robust and fully functional computer-based procedure which has proven a very useful tool for sample classification or cataloging purposes as well as for integrating soil colour data with other remote sensed and spatial data sets.
Griffin, M.S.; Martin, G.R.; White, K.D.
1994-01-01
This report describes selected data-collection activities and the associated data collected during the Kentucky River Basin pilot study of the U.S. Geological Survey's National Water-Quality Assessment Program. The data are intended to provide a nationally consistent description and improved understanding of current water quality in the basin. The data were collected at seven fixed stations that represent stream cross sections where constituent transport and water-quality trends can be evaluated. The report includes descriptions of (1) the basin; (2) the design of the fixed-station network; (3) the fixed-station sites; (4) the physical and chemical measurements; (5) the methods of sample collection, processing, and analysis; and (6) the quality-assurance and quality-control procedures. Water-quality data collected at the fixed stations during routine periodic sampling and supplemental high-flow sampling from April 1987 to August 1991 are presented.
A self-sampling method to obtain large volumes of undiluted cervicovaginal secretions.
Boskey, Elizabeth R; Moench, Thomas R; Hees, Paul S; Cone, Richard A
2003-02-01
Studies of vaginal physiology and pathophysiology sometime require larger volumes of undiluted cervicovaginal secretions than can be obtained by current methods. A convenient method for self-sampling these secretions outside a clinical setting can facilitate such studies of reproductive health. The goal was to develop a vaginal self-sampling method for collecting large volumes of undiluted cervicovaginal secretions. A menstrual collection device (the Instead cup) was inserted briefly into the vagina to collect secretions that were then retrieved from the cup by centrifugation in a 50-ml conical tube. All 16 women asked to perform this procedure found it feasible and acceptable. Among 27 samples, an average of 0.5 g of secretions (range, 0.1-1.5 g) was collected. This is a rapid and convenient self-sampling method for obtaining relatively large volumes of undiluted cervicovaginal secretions. It should prove suitable for a wide range of assays, including those involving sexually transmitted diseases, microbicides, vaginal physiology, immunology, and pathophysiology.
MICROBIAL LABORATORY GUIDANCE MANUAL FOR THE ...
The Long-Term 2 Enhanced Surface Water Treatment Rule Laboratory Instruction Manual will be a compilation of all information needed by laboratories and field personnel to collect, analyze, and report the microbiological data required under the rule. The manual will provide laboratories with a single source of information that currently is available from various sources including the latest versions of Methods 1622 and 1623, including all approved, equivalent modifications; the procedures for E.coli methods approved for use under the LT2ESWTR; lists of vendor sources; data recording forms; data reporting requirements; information on the Laboratory Quality Assurance Evaluation Program for the Analysis of Cryptosporidium in Water; and sample collection procedures. Although most of this information is available elsewhere, a single, comprehensive compendium containing this information is needed to aid utilities and laboratories performing the sampling and analysis activities required under the LT2 rule. This manual will serve as an instruction manual for laboratories to use when collecting data for Crypto, E. coli and turbidity.
Collection of biological samples in forensic toxicology.
Dinis-Oliveira, R J; Carvalho, F; Duarte, J A; Remião, F; Marques, A; Santos, A; Magalhães, T
2010-09-01
Forensic toxicology is the study and practice of the application of toxicology to the purposes of the law. The relevance of any finding is determined, in the first instance, by the nature and integrity of the specimen(s) submitted for analysis. This means that there are several specific challenges to select and collect specimens for ante-mortem and post-mortem toxicology investigation. Post-mortem specimens may be numerous and can endow some special difficulties compared to clinical specimens, namely those resulting from autolytic and putrefactive changes. Storage stability is also an important issue to be considered during the pre-analytic phase, since its consideration should facilitate the assessment of sample quality and the analytical result obtained from that sample. The knowledge on degradation mechanisms and methods to increase storage stability may enable the forensic toxicologist to circumvent possible difficulties. Therefore, advantages and limitations of specimen preservation procedures are thoroughfully discussed in this review. Presently, harmonized protocols for sampling in suspected intoxications would have obvious utility. In the present article an overview is given on sampling procedures for routinely collected specimens as well as on alternative specimens that may provide additional information on the route and timing of exposure to a specific xenobiotic. Last, but not least, a discussion on possible bias that can influence the interpretation of toxicological results is provided. This comprehensive review article is intented as a significant help for forensic toxicologists to accomplish their frequently overwhelming mission.
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2001-01-01
A laboratory for analysis of low-ionic strength water has been developed at the U.S. Geological Survey (USGS) office in Troy, N.Y., to analyze samples collected by USGS projects in the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures developed to ensure proper sample collection, processing, and analysis. The quality-assurance/quality-control data are stored in the laboratory's SAS data-management system, which provides efficient review, compilation, and plotting of quality-assurance/quality-control data. This report presents and discusses samples analyzed from July 1993 through June 1995. Quality-control results for 18 analytical procedures were evaluated for bias and precision. Control charts show that data from seven of the analytical procedures were biased throughout the analysis period for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, dissolved inorganic carbon, dissolved organic carbon (soil expulsions), chloride, magnesium, nitrate (colorimetric method), and pH. Three of the analytical procedures were occasionally biased but were within control limits; they were: calcium (high for high-concentration samples for May 1995), dissolved organic carbon (high for highconcentration samples from January through September 1994), and fluoride (high in samples for April and June 1994). No quality-control sample has been developed for the organic monomeric aluminum procedure. Results from the filter-blank and analytical-blank analyses indicate that all analytical procedures in which blanks were run were within control limits, although values for a few blanks were outside the control limits. Blanks were not analyzed for acid-neutralizing capacity, dissolved inorganic carbon, fluoride, nitrate (colorimetric method), or pH. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in 14 of the 18 procedures. Data-quality objectives were met by more than 90 percent of the samples analyzed in all procedures except total monomeric aluminum (85 percent of samples met objectives), total aluminum (70 percent of samples met objectives), and dissolved organic carbon (85 percent of samples met objectives). Triplicate samples were not analyzed for ammonium, fluoride, dissolved inorganic carbon, or nitrate (colorimetric method). Results of the USGS interlaboratory Standard Reference Sample Program indicated high data quality with a median result of 3.6 of a possible 4.0. Environment Canada's LRTAP interlaboratory study results indicated that more than 85 percent of the samples met data-quality objectives in 6 of the 12 analyses; exceptions were calcium, dissolved organic carbon, chloride, pH, potassium, and sodium. Data-quality objectives were not met for calcium samples in one LRTAP study, but 94 percent of samples analyzed were within control limits for the remaining studies. Data-quality objectives were not met by 35 percent of samples analyzed for dissolved organic carbon, but 94 percent of sample values were within 20 percent of the most probable value. Data-quality objectives were not met for 30 percent of samples analyzed for chloride, but 90 percent of sample values were within 20 percent of the most probable value. Measurements of samples with a pH above 6.0 were biased high in 54 percent of the samples, although 85 percent of the samples met data-quality objectives for pH measurements below 6.0. Data-quality objectives for potassium and sodium were not met in one study (only 33 percent of the samples analyzed met the objectives), although 85 percent of the sample values were within control limits for the other studies. Measured sodium values were above the upper control limit in all studies. Results from blind reference-sample analyses indicated that data
Nilles, M.A.; Gordon, J.D.; Schroder, L.J.
1994-01-01
A collocated, wet-deposition sampler program has been operated since October 1988 by the U.S. Geological Survey to estimate the overall sampling precision of wet atmospheric deposition data collected at selected sites in the National Atmospheric Deposition Program and National Trends Network (NADP/NTN). A duplicate set of wet-deposition sampling instruments was installed adjacent to existing sampling instruments at four different NADP/NTN sites for each year of the study. Wet-deposition samples from collocated sites were collected and analysed using standard NADP/NTN procedures. Laboratory analyses included determinations of pH, specific conductance, and concentrations of major cations and anions. The estimates of precision included all variability in the data-collection system, from the point of sample collection through storage in the NADP/NTN database. Sampling precision was determined from the absolute value of differences in the analytical results for the paired samples in terms of median relative and absolute difference. The median relative difference for Mg2+, Na+, K+ and NH4+ concentration and deposition was quite variable between sites and exceeded 10% at most sites. Relative error for analytes whose concentrations typically approached laboratory method detection limits were greater than for analytes that did not typically approach detection limits. The median relative difference for SO42- and NO3- concentration, specific conductance, and sample volume at all sites was less than 7%. Precision for H+ concentration and deposition ranged from less than 10% at sites with typically high levels of H+ concentration to greater than 30% at sites with low H+ concentration. Median difference for analyte concentration and deposition was typically 1.5-2-times greater for samples collected during the winter than during other seasons at two northern sites. Likewise, the median relative difference in sample volume for winter samples was more than double the annual median relative difference at the two northern sites. Bias accounted for less than 25% of the collocated variability in analyte concentration and deposition from weekly collocated precipitation samples at most sites.A collocated, wet-deposition sampler program has been operated since OCtober 1988 by the U.S Geological Survey to estimate the overall sampling precision of wet atmospheric deposition data collected at selected sites in the National Atmospheric Deposition Program and National Trends Network (NADP/NTN). A duplicate set of wet-deposition sampling instruments was installed adjacent to existing sampling instruments four different NADP/NTN sites for each year of the study. Wet-deposition samples from collocated sites were collected and analysed using standard NADP/NTN procedures. Laboratory analyses included determinations of pH, specific conductance, and concentrations of major cations and anions. The estimates of precision included all variability in the data-collection system, from the point of sample collection through storage in the NADP/NTN database.
Influence of Freezing and Storage Procedure on Human Urine Samples in NMR-Based Metabolomics
Rist, Manuela J.; Muhle-Goll, Claudia; Görling, Benjamin; Bub, Achim; Heissler, Stefan; Watzl, Bernhard; Luy, Burkhard
2013-01-01
It is consensus in the metabolomics community that standardized protocols should be followed for sample handling, storage and analysis, as it is of utmost importance to maintain constant measurement conditions to identify subtle biological differences. The aim of this work, therefore, was to systematically investigate the influence of freezing procedures and storage temperatures and their effect on NMR spectra as a potentially disturbing aspect for NMR-based metabolomics studies. Urine samples were collected from two healthy volunteers, centrifuged and divided into aliquots. Urine aliquots were frozen either at −20 °C, on dry ice, at −80 °C or in liquid nitrogen and then stored at −20 °C, −80 °C or in liquid nitrogen vapor phase for 1–5 weeks before NMR analysis. Results show spectral changes depending on the freezing procedure, with samples frozen on dry ice showing the largest deviations. The effect was found to be based on pH differences, which were caused by variations in CO2 concentrations introduced by the freezing procedure. Thus, we recommend that urine samples should be frozen at −20 °C and transferred to lower storage temperatures within one week and that freezing procedures should be part of the publication protocol. PMID:24957990
Influence of Freezing and Storage Procedure on Human Urine Samples in NMR-Based Metabolomics.
Rist, Manuela J; Muhle-Goll, Claudia; Görling, Benjamin; Bub, Achim; Heissler, Stefan; Watzl, Bernhard; Luy, Burkhard
2013-04-09
It is consensus in the metabolomics community that standardized protocols should be followed for sample handling, storage and analysis, as it is of utmost importance to maintain constant measurement conditions to identify subtle biological differences. The aim of this work, therefore, was to systematically investigate the influence of freezing procedures and storage temperatures and their effect on NMR spectra as a potentially disturbing aspect for NMR-based metabolomics studies. Urine samples were collected from two healthy volunteers, centrifuged and divided into aliquots. Urine aliquots were frozen either at -20 °C, on dry ice, at -80 °C or in liquid nitrogen and then stored at -20 °C, -80 °C or in liquid nitrogen vapor phase for 1-5 weeks before NMR analysis. Results show spectral changes depending on the freezing procedure, with samples frozen on dry ice showing the largest deviations. The effect was found to be based on pH differences, which were caused by variations in CO2 concentrations introduced by the freezing procedure. Thus, we recommend that urine samples should be frozen at -20 °C and transferred to lower storage temperatures within one week and that freezing procedures should be part of the publication protocol.
Does the public notice visual resource problems on the federal estate?
John D. Peine
1979-01-01
Results of the 1977 Federal estate are highlighted. The survey of recreation on the Federal estate represents a unique data set which was uniformly collected across all Federal land managing agencies and sections of the country. The on-site sampling procedures utilized in this survey process have never before been applied on such a large scale. Procedures followed and...
ERIC Educational Resources Information Center
Bachman, Jerald G.; Johnston, Lloyd D.; O'Malley, Patrick M.; Schulenberg, John E.; Miech, Richard A.
2015-01-01
The purpose of this paper is to provide a detailed description of the Monitoring the Future research design, including sampling design, data collection procedures, measurement content, and questionnaire format. This study assesses the changing lifestyles, values, and preferences of American youth on a continuing basis. Each year since 1975, at…
Holding effects on coliform enumeration in drinking water samples.
McDaniels, A E; Bordner, R H; Gartside, P S; Haines, J R; Brenner, K P; Rankin, C C
1985-01-01
Standard procedures for analyzing drinking water stress the need to adhere to the time and temperature conditions recommended for holding samples collected for microbiological testing. The National Drinking Water Laboratory Certification Program requires compliance with these holding limits, but some investigators have reported difficulties in meeting them. Research was conducted by standard analytical methods to determine if changes occurred when samples were held at 5 and 22 degrees C and analyzed at 0, 24, 30, and 48 h. Samples were analyzed for coliforms by the membrane filter and fermentation-tube procedures and for heterotrophs by the pour plate method. A total of 17 treated water samples were collected from a large municipal distribution system from August to December 1981, and 12 samples were collected from January to May 1983. The samples were dosed with coliforms previously isolated from the water system, Enterobacter cloacae in 1981 and Citrobacter freundii in 1983. The coliform counts declined linearly over time, and the rates of decline were significant at both 5 and 22 degrees C. Within 24 h at 22 degrees C, levels of E. cloacae and C. freundii decreased by 47 and 26%, respectively, and at 5 degrees C, E. cloacae numbers declined by 23%. Results from these representative laboratory-grown coliforms reinforced those previously obtained with naturally occurring coliforms under the same experimental conditions. Significantly, some samples with initially unacceptable counts (greater than 4/100 ml) met the safe drinking water limits after storage at 24 h at 5 and 22 degrees C and would have been classified as satisfactory.(ABSTRACT TRUNCATED AT 250 WORDS) Images PMID:4083877
ERIC Educational Resources Information Center
Wagner, Stephen C.; Stewart, Robert S., Jr.
2000-01-01
Introduces an investigative microbiology laboratory activity emphasizing critical thinking and experimental design in which students isolate and characterize a bacterium from a specific habitat. Explains the procedures of the laboratory including safety, sample collection, and isolation. (YDS)
Carter, James L.; Resh, Vincent H.
2001-01-01
A survey of methods used by US state agencies for collecting and processing benthic macroinvertebrate samples from streams was conducted by questionnaire; 90 responses were received and used to describe trends in methods. The responses represented an estimated 13,000-15,000 samples collected and processed per year. Kicknet devices were used in 64.5% of the methods; other sampling devices included fixed-area samplers (Surber and Hess), artificial substrates (Hester-Dendy and rock baskets), grabs, and dipnets. Regional differences existed, e.g., the 1-m kicknet was used more often in the eastern US than in the western US. Mesh sizes varied among programs but 80.2% of the methods used a mesh size between 500 and 600 (mu or u)m. Mesh size variations within US Environmental Protection Agency regions were large, with size differences ranging from 100 to 700 (mu or u)m. Most samples collected were composites; the mean area sampled was 1.7 m2. Samples rarely were collected using a random method (4.7%); most samples (70.6%) were collected using "expert opinion", which may make data obtained operator-specific. Only 26.3% of the methods sorted all the organisms from a sample; the remainder subsampled in the laboratory. The most common method of subsampling was to remove 100 organisms (range = 100-550). The magnification used for sorting ranged from 1 (sorting by eye) to 30x, which results in inconsistent separation of macroinvertebrates from detritus. In addition to subsampling, 53% of the methods sorted large/rare organisms from a sample. The taxonomic level used for identifying organisms varied among taxa; Ephemeroptera, Plecoptera, and Trichoptera were generally identified to a finer taxonomic resolution (genus and species) than other taxa. Because there currently exists a large range of field and laboratory methods used by state programs, calibration among all programs to increase data comparability would be exceptionally challenging. However, because many techniques are shared among methods, limited testing could be designed to evaluate whether procedural differences affect the ability to determine levels of environmental impairment using benthic macroinvertebrate communities.
Outcome-Dependent Sampling Design and Inference for Cox's Proportional Hazards Model.
Yu, Jichang; Liu, Yanyan; Cai, Jianwen; Sandler, Dale P; Zhou, Haibo
2016-11-01
We propose a cost-effective outcome-dependent sampling design for the failure time data and develop an efficient inference procedure for data collected with this design. To account for the biased sampling scheme, we derive estimators from a weighted partial likelihood estimating equation. The proposed estimators for regression parameters are shown to be consistent and asymptotically normally distributed. A criteria that can be used to optimally implement the ODS design in practice is proposed and studied. The small sample performance of the proposed method is evaluated by simulation studies. The proposed design and inference procedure is shown to be statistically more powerful than existing alternative designs with the same sample sizes. We illustrate the proposed method with an existing real data from the Cancer Incidence and Mortality of Uranium Miners Study.
Bacteria associated with granular activated carbon particles in drinking water.
Camper, A K; LeChevallier, M W; Broadaway, S C; McFeters, G A
1986-01-01
A sampling protocol was developed to examine particles released from granular activated carbon filter beds. A gauze filter/Swinnex procedure was used to collect carbon fines from 201 granular activated carbon-treated drinking water samples over 12 months. Application of a homogenization procedure (developed previously) indicated that 41.4% of the water samples had heterotrophic plate count bacteria attached to carbon particles. With the enumeration procedures described, heterotrophic plate count bacteria were recovered at an average rate of 8.6 times higher than by conventional analyses. Over 17% of the samples contained carbon particles colonized with coliform bacteria as enumerated with modified most-probable-number and membrane filter techniques. In some instances coliform recoveries were 122 to 1,194 times higher than by standard procedures. Nearly 28% of the coliforms attached to these particles in drinking water exhibited the fecal biotype. Scanning electron micrographs of carbon fines from treated drinking water showed microcolonies of bacteria on particle surfaces. These data indicate that bacteria attached to carbon fines may be an important mechanism by which microorganisms penetrate treatment barriers and enter potable water supplies. PMID:3767356
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brandenberger, Jill M.; Metallo, David; Rupert, Brian
2013-07-03
Annual PSNS non-dry dock storm water monitoring results for 2011-2012 storm season. Included are a brief description of the sampling procedures, storm event information, laboratory methods and data collection, a results and discussion section, and the conclusions and recommendations.
Robert E. Keane
2006-01-01
The Metadata (MD) table in the FIREMON database is used to record any information about the sampling strategy or data collected using the FIREMON sampling procedures. The MD method records metadata pertaining to a group of FIREMON plots, such as all plots in a specific FIREMON project. FIREMON plots are linked to metadata using a unique metadata identifier that is...
Use of Passive Diffusion Samplers for Monitoring Volatile Organic Compounds in Ground Water
Harte, Philip T.; Brayton, Michael J.; Ives, Wayne
2000-01-01
Passive diffusion samplers have been tested at a number of sites where volatile organic compounds (VOC's) are the principal contaminants in ground water. Test results generally show good agreement between concentrations of VOC's in samples collected with diffusion samplers and concentrations in samples collected by purging the water from a well. Diffusion samplers offer several advantages over conventional and low-flow ground-water sampling procedures: * Elimination of the need to purge a well before collecting a sample and to dispose of contaminated water. * Elimination of cross-contamination of samples associated with sampling with non-dedicated pumps or sample delivery tubes. * Reduction in sampling time by as much as 80 percent of that required for 'purge type' sampling methods. * An increase in the frequency and spatial coverage of monitoring at a site because of the associated savings in time and money. The successful use of diffusion samplers depends on the following three primary factors: (1) understanding site conditions and contaminants of interest (defining sample objectives), (2) validating of results of diffusion samplers against more widely acknowledged sampling methods, and (3) applying diffusion samplers in the field.
USGS GeoData Digital Raster Graphics
,
2001-01-01
Passive diffusion samplers have been tested at a number of sites where volatile organic compounds (VOC?s) are the principal contaminants in ground water. Test results generally show good agreement between concentrations of VOC?s in samples collected with diffusion samplers and concentrations in samples collected by purging the water from a well. Diffusion samplers offer several advantages over conventional and low-flow ground-water sampling procedures: ? Elimination of the need to purge a well before collecting a sample and to dispose of contaminated water. ? Elimination of cross-contamination of samples associated with sampling with non-dedicated pumps or sample delivery tubes. ? Reduction in sampling time by as much as 80 percent of that required for ?purge type? sampling methods. ? An increase in the frequency and spatial coverage of monitoring at a site because of the associated savings in time and money. The successful use of diffusion samplers depends on the following three primary factors: (1) understanding site conditions and contaminants of interest (defining sample objectives), (2) validating of results of diffusion samplers against more widely acknowledged sampling methods, and (3) applying diffusion samplers in the field.
21 CFR 868.1575 - Gas collection vessel.
Code of Federal Regulations, 2012 CFR
2012-04-01
... for subsequent analysis. It does not include a sampling pump. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this...
The focus on sample quality: Influence of colon tissue collection on reliability of qPCR data
Korenkova, Vlasta; Slyskova, Jana; Novosadova, Vendula; Pizzamiglio, Sara; Langerova, Lucie; Bjorkman, Jens; Vycital, Ondrej; Liska, Vaclav; Levy, Miroslav; Veskrna, Karel; Vodicka, Pavel; Vodickova, Ludmila; Kubista, Mikael; Verderio, Paolo
2016-01-01
Successful molecular analyses of human solid tissues require intact biological material with well-preserved nucleic acids, proteins, and other cell structures. Pre-analytical handling, comprising of the collection of material at the operating theatre, is among the first critical steps that influence sample quality. The aim of this study was to compare the experimental outcomes obtained from samples collected and stored by the conventional means of snap freezing and by PAXgene Tissue System (Qiagen). These approaches were evaluated by measuring rRNA and mRNA integrity of the samples (RNA Quality Indicator and Differential Amplification Method) and by gene expression profiling. The collection procedures of the biological material were implemented in two hospitals during colon cancer surgery in order to identify the impact of the collection method on the experimental outcome. Our study shows that the pre-analytical sample handling has a significant effect on the quality of RNA and on the variability of qPCR data. PAXgene collection mode proved to be more easily implemented in the operating room and moreover the quality of RNA obtained from human colon tissues by this method is superior to the one obtained by snap freezing. PMID:27383461
Level 1 environmental assessment performance evaluation. Final report jun 77-oct 78
DOE Office of Scientific and Technical Information (OSTI.GOV)
Estes, E.D.; Smith, F.; Wagoner, D.E.
1979-02-01
The report gives results of a two-phased evaluation of Level 1 environmental assessment procedures. Results from Phase I, a field evaluation of the Source Assessment Sampling System (SASS), showed that the SASS train performed well within the desired factor of 3 Level 1 accuracy limit. Three sample runs were made with two SASS trains sampling simultaneously and from approximately the same sampling point in a horizontal duct. A Method-5 train was used to estimate the 'true' particulate loading. The sampling systems were upstream of the control devices to ensure collection of sufficient material for comparison of total particulate, particle sizemore » distribution, organic classes, and trace elements. Phase II consisted of providing each of three organizations with three types of control samples to challenge the spectrum of Level 1 analytical procedures: an artificial sample in methylene chloride, an artificial sample on a flyash matrix, and a real sample composed of the combined XAD-2 resin extracts from all Phase I runs. Phase II results showed that when the Level 1 analytical procedures are carefully applied, data of acceptable accuracy is obtained. Estimates of intralaboratory and interlaboratory precision are made.« less
USDA-ARS?s Scientific Manuscript database
The validity of data in science depends on the reliability of the collection procedure and the methods used for data analysis. This becomes a major challenge in studies of mucosal immunology since samples for analysis come from various anatomical sources which differ remarkably in their content and ...
Code of Federal Regulations, 2010 CFR
2010-07-01
... two separate components. The first data collection component demonstrates that the open biological... each zone of the open biological treatment unit. After the first two components of data collection are... determined using actual sampling data from the open biological treatment unit. This is done during the...
Code of Federal Regulations, 2011 CFR
2011-07-01
... two separate components. The first data collection component demonstrates that the open biological... each zone of the open biological treatment unit. After the first two components of data collection are... determined using actual sampling data from the open biological treatment unit. This is done during the...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kahraman, A. G.; Kaynak, G.; Akkaya, G.
Mosses are one of the most widely used procedures to determine via plant of radioactive contamination. The high concentrating capacity of mosses may be used as bioindicator of environmental radioactive contamination. In this study, the mosses were collected in region of Katirli Mountain in northwestern Turkey, activities were determined using TENNELEC LB 1000-PW detector. Samples of mosses growing on soil, rock, and tree bark were collected.
Moranda, Arianna
2017-01-01
A procedure for assessing harbour pollution by heavy metals and PAH and the possible sources of contamination is proposed. The procedure is based on a ratio-matching method applied to the results of principal component analysis (PCA), and it allows discrimination between point and nonpoint sources. The approach can be adopted when many sources of pollution can contribute in a very narrow coastal ecosystem, both internal and outside but close to the harbour, and was used to identify the possible point sources of contamination in a Mediterranean Harbour (Port of Vado, Savona, Italy). 235 sediment samples were collected in 81 sampling points during four monitoring campaigns and 28 chemicals were searched for within the collected samples. PCA of total samples allowed the assessment of 8 main possible point sources, while the refining ratio-matching identified 1 sampling point as a possible PAH source, 2 sampling points as Cd point sources, and 3 sampling points as C > 12 point sources. By a map analysis it was possible to assess two internal sources of pollution directly related to terminals activity. The study is the prosecution of a previous work aimed at assessing Savona-Vado Harbour pollution levels and suggested strategies to regulate the harbour activities. PMID:29270328
Paladino, Ombretta; Moranda, Arianna; Seyedsalehi, Mahdi
2017-01-01
A procedure for assessing harbour pollution by heavy metals and PAH and the possible sources of contamination is proposed. The procedure is based on a ratio-matching method applied to the results of principal component analysis (PCA), and it allows discrimination between point and nonpoint sources. The approach can be adopted when many sources of pollution can contribute in a very narrow coastal ecosystem, both internal and outside but close to the harbour, and was used to identify the possible point sources of contamination in a Mediterranean Harbour (Port of Vado, Savona, Italy). 235 sediment samples were collected in 81 sampling points during four monitoring campaigns and 28 chemicals were searched for within the collected samples. PCA of total samples allowed the assessment of 8 main possible point sources, while the refining ratio-matching identified 1 sampling point as a possible PAH source, 2 sampling points as Cd point sources, and 3 sampling points as C > 12 point sources. By a map analysis it was possible to assess two internal sources of pollution directly related to terminals activity. The study is the prosecution of a previous work aimed at assessing Savona-Vado Harbour pollution levels and suggested strategies to regulate the harbour activities.
Presley, Todd K.; Jamison, Marcael T.J.; Young, Stacie T.M.
2008-01-01
Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. The program is designed to assess the effects of highway runoff and urban runoff on Halawa Stream and to assess the effects from the H-1 storm drain on Manoa Stream. For this program, rainfall data were collected at three stations, continuous discharge data at four stations, and water-quality data at six stations, which include the four continuous discharge stations. This report summarizes rainfall, discharge, and water-quality data collected between July 1, 2007, and June 30, 2008. A total of 16 environmental samples were collected over two storms during July 1, 2007, to June 30, 2008, within the Halawa Stream drainage area. Samples were analyzed for total suspended solids, total dissolved solids, nutrients, chemical oxygen demand, and selected trace metals (cadmium, chromium, copper, lead, and zinc). Additionally, grab samples were analyzed for oil and grease, total petroleum hydrocarbons, fecal coliform, and biological oxygen demand. Some samples were analyzed for only a partial list of these analytes because an insufficient volume of sample was collected by the automatic samplers. Three additional quality-assurance/quality-control samples were collected concurrently with the storm samples. A total of 16 environmental samples were collected over four storms during July 1, 2007, to June 30, 2008 at the H-1 Storm Drain. All samples at this site were collected using an automatic sampler. Samples generally were analyzed for total suspended solids, nutrients, chemical oxygen demand, oil and grease, total petroleum hydrocarbons, and selected trace metals (cadmium, chromium, copper, lead, nickel, and zinc), although some samples were analyzed for only a partial list of these analytes. During the storm of January 29, 2008, 10 discrete samples were collected. Varying constituent concentrations were detected for the samples collected at different times during this storm event. Two quality-assurance/quality-control samples were collected concurrently with the storm samples. Three additional quality-assurance/quality-control samples were collected during routine sampler maintenance to check the effectiveness of equipment-cleaning procedures.
Dukić, Lora; Kopčinović, Lara Milevoj; Dorotić, Adrijana; Baršić, Ivana
2016-10-15
Blood gas analysis (BGA) is exposed to risks of errors caused by improper sampling, transport and storage conditions. The Clinical and Laboratory Standards Institute (CLSI) generated documents with recommendations for avoidance of potential errors caused by sample mishandling. Two main documents related to BGA issued by the CLSI are GP43-A4 (former H11-A4) Procedures for the collection of arterial blood specimens; approved standard - fourth edition, and C46-A2 Blood gas and pH analysis and related measurements; approved guideline - second edition. Practices related to processing of blood gas samples are not standardized in the Republic of Croatia. Each institution has its own protocol for ordering, collection and analysis of blood gases. Although many laboratories use state of the art analyzers, still many preanalytical procedures remain unchanged. The objective of the Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM) is to standardize the procedures for BGA based on CLSI recommendations. The Working Group for Blood Gas Testing as part of the Committee for the Scientific Professional Development of the CSMBLM prepared a set of recommended protocols for sampling, transport, storage and processing of blood gas samples based on relevant CLSI documents, relevant literature search and on the results of Croatian survey study on practices and policies in acid-base testing. Recommendations are intended for laboratory professionals and all healthcare workers involved in blood gas processing.
Dukić, Lora; Kopčinović, Lara Milevoj; Dorotić, Adrijana; Baršić, Ivana
2016-01-01
Blood gas analysis (BGA) is exposed to risks of errors caused by improper sampling, transport and storage conditions. The Clinical and Laboratory Standards Institute (CLSI) generated documents with recommendations for avoidance of potential errors caused by sample mishandling. Two main documents related to BGA issued by the CLSI are GP43-A4 (former H11-A4) Procedures for the collection of arterial blood specimens; approved standard – fourth edition, and C46-A2 Blood gas and pH analysis and related measurements; approved guideline – second edition. Practices related to processing of blood gas samples are not standardized in the Republic of Croatia. Each institution has its own protocol for ordering, collection and analysis of blood gases. Although many laboratories use state of the art analyzers, still many preanalytical procedures remain unchanged. The objective of the Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM) is to standardize the procedures for BGA based on CLSI recommendations. The Working Group for Blood Gas Testing as part of the Committee for the Scientific Professional Development of the CSMBLM prepared a set of recommended protocols for sampling, transport, storage and processing of blood gas samples based on relevant CLSI documents, relevant literature search and on the results of Croatian survey study on practices and policies in acid-base testing. Recommendations are intended for laboratory professionals and all healthcare workers involved in blood gas processing. PMID:27812301
Qamar, Wajhul
2015-01-01
Bronchoalveolar lavage fluid (BALF) is an important tool in experimental toxicology and pharmacology. A number of researchers have utilized BAL in studies involving rodents. However, the detailed procedure of performing BAL in rodents has rarely been reported. In the present article, in situ BAL in rats has been described with technical points that ensure the quality and validity of BALF samples. BAL was performed in rats of Wistar strain. Flow cytometry and microscopy were utilized to analyze the BAL cells. The collected volume of BALF was 84.32 ± 2.7% of instilled volume. Alveolar macrophages were found to be prevalent in normal lungs when analyzed under microscope and by flow cytometry. The main problem that one may face is the accidental contamination of BALF samples with blood of the animal itself. Presence of blood in BALF certainly adds a significant number of cells and other biochemical variables. No blood contamination was detected in BALF. Here, a simple procedure for BAL and collection of alveolar cells (macrophages in the present study) is explained with an emphasis on technical steps and precautions, which ensures the quality of the BALF samples. Data exhibit that there is no blood contamination in the BALF and provide evidence that the technical points considered in the procedure here are successful in maintaining the quality and validity of BALF samples.
Sampling pig farms at the abattoir in a cross-sectional study - Evaluation of a sampling method.
Birkegård, Anna Camilla; Halasa, Tariq; Toft, Nils
2017-09-15
A cross-sectional study design is relatively inexpensive, fast and easy to conduct when compared to other study designs. Careful planning is essential to obtaining a representative sample of the population, and the recommended approach is to use simple random sampling from an exhaustive list of units in the target population. This approach is rarely feasible in practice, and other sampling procedures must often be adopted. For example, when slaughter pigs are the target population, sampling the pigs on the slaughter line may be an alternative to on-site sampling at a list of farms. However, it is difficult to sample a large number of farms from an exact predefined list, due to the logistics and workflow of an abattoir. Therefore, it is necessary to have a systematic sampling procedure and to evaluate the obtained sample with respect to the study objective. We propose a method for 1) planning, 2) conducting, and 3) evaluating the representativeness and reproducibility of a cross-sectional study when simple random sampling is not possible. We used an example of a cross-sectional study with the aim of quantifying the association of antimicrobial resistance and antimicrobial consumption in Danish slaughter pigs. It was not possible to visit farms within the designated timeframe. Therefore, it was decided to use convenience sampling at the abattoir. Our approach was carried out in three steps: 1) planning: using data from meat inspection to plan at which abattoirs and how many farms to sample; 2) conducting: sampling was carried out at five abattoirs; 3) evaluation: representativeness was evaluated by comparing sampled and non-sampled farms, and the reproducibility of the study was assessed through simulated sampling based on meat inspection data from the period where the actual data collection was carried out. In the cross-sectional study samples were taken from 681 Danish pig farms, during five weeks from February to March 2015. The evaluation showed that the sampling procedure was reproducible with results comparable to the collected sample. However, the sampling procedure favoured sampling of large farms. Furthermore, both under-sampled and over-sampled areas were found using scan statistics. In conclusion, sampling conducted at abattoirs can provide a spatially representative sample. Hence it is a possible cost-effective alternative to simple random sampling. However, it is important to assess the properties of the resulting sample so that any potential selection bias can be addressed when reporting the findings. Copyright © 2017 Elsevier B.V. All rights reserved.
Godish, Diana; Godish, Thad
2008-02-01
This study was conducted to evaluate (i) procedures used to collect, prepare, and count total airborne mold spore/particle concentrations, and (ii) the relative field performance of three commercially available total airborne mold spore/particle sampling devices. Differences between factory and laboratory airflow calibration values of axial fan-driven sampling instruments (used in the study) indicated a need for laboratory calibration using a mass flow meter to ensure that sample results were accurately calculated. An aniline blue-amended Calberla's solution adjusted to a pH of 4.2-4.4 provided good sample mounting/counting results using Dow Corning high vacuum grease, Dow Corning 280A adhesive, and Dow Corning 316 silicone release spray for samples collected using mini-Burkard and Allergenco samplers. Count variability among analysts was most pronounced in 5% counts of relatively low mold particle deposition density samples and trended downward with increased count percentage and particle deposition density. No significant differences were observed among means of 5, 10, and 20% counts and among analysts; a significant interaction effect was observed between analysts' counts and particle deposition densities. Significantly higher mini-Burkard and Air-O-Cell total mold spore/particle counts for 600x vs. 400x (1.9 and 2.3 x higher, respectively), 1000x vs. 600x (1.9 and 2.2 x higher, respectively) and 1000x vs. 400x (3.6 and 4.6 x higher, respectively) comparisons indicated that 1000x magnification counts best quantified total airborne mold spore/particles using light microscopy, and that lower magnification counts may result in unacceptable underreporting of airborne mold spore/particle concentrations. Modest but significantly higher (1.2x) total mold spore concentrations were observed with Allergenco vs. mini-Burkard samples collected in co-located, concurrently operated sampler studies; moderate but significantly higher mini-Burkard count values (1.4x) were observed in similar studies with Air-O-Cell samplers. These count differences were relatively small compared with the large differences observed among three count magnifications.
ERIC Educational Resources Information Center
McPhee, C.; Bielick, S.; Masterton, M.; Flores, L.; Parmer, R.; Amchin, S.; Stern, S.; McGowan, H.
2015-01-01
The 2012 National Household Education Surveys Program (NHES:2012) Data File User's Manual provides documentation and guidance for users of the NHES:2012 data files. The manual provides information about the purpose of the study, the sample design, data collection procedures, data processing procedures, response rates, imputation, weighting and…
Collecting, archiving and processing DNA from wildlife samples using FTA® databasing paper
Smith, LM; Burgoyne, LA
2004-01-01
Background Methods involving the analysis of nucleic acids have become widespread in the fields of traditional biology and ecology, however the storage and transport of samples collected in the field to the laboratory in such a manner to allow purification of intact nucleic acids can prove problematical. Results FTA® databasing paper is widely used in human forensic analysis for the storage of biological samples and for purification of nucleic acids. The possible uses of FTA® databasing paper in the purification of DNA from samples of wildlife origin were examined, with particular reference to problems expected due to the nature of samples of wildlife origin. The processing of blood and tissue samples, the possibility of excess DNA in blood samples due to nucleated erythrocytes, and the analysis of degraded samples were all examined, as was the question of long term storage of blood samples on FTA® paper. Examples of the end use of the purified DNA are given for all protocols and the rationale behind the processing procedures is also explained to allow the end user to adjust the protocols as required. Conclusions FTA® paper is eminently suitable for collection of, and purification of nucleic acids from, biological samples from a wide range of wildlife species. This technology makes the collection and storage of such samples much simpler. PMID:15072582
Design and Installation of Monitoring Wells Guidance
EPA Region 4 Science and Ecosystem Support Division (SESD) document, from Feb. 18, 2008, that describes procedures, methods, and considerations when designing and installing groundwater monitoring wells to be used for collection of groundwater samples.
Applications and use of transportation data
DOT National Transportation Integrated Search
1979-01-01
This research paper is a compilation of seven documents which focus on the application and use of transportation data. The following papers are included: "Field data collection and sampling procedures for measuring regional vehicle classification and...
Cross-Cultural Validation of the Patient Perception of Integrated Care Survey.
Tietschert, Maike V; Angeli, Federica; van Raak, Arno J A; Ruwaard, Dirk; Singer, Sara J
2017-07-20
To test the cross-cultural validity of the U.S. Patient Perception of Integrated Care (PPIC) Survey in a Dutch sample using a standardized procedure. Primary data collected from patients of five primary care centers in the south of the Netherlands, through survey research from 2014 to 2015. Cross-sectional data collected from patients who saw multiple health care providers during 6 months preceding data collection. The PPIC survey includes 59 questions that measure patient perceived care integration across providers, settings, and time. Data analysis followed a standardized procedure guiding data preparation, psychometric analysis, and included invariance testing with the U.S. dataset. Latent scale structures of the Dutch and U.S. survey were highly comparable. Factor "Integration with specialist" had lower reliability scores and noninvariance. For the remaining factors, internal consistency and invariance estimates were strong. The standardized cross-cultural validation procedure produced strong support for comparable psychometric characteristics of the Dutch and U.S. surveys. Future research should examine the usability of the proposed procedure for contexts with greater cultural differences. © Health Research and Educational Trust.
Preliminary Assessment/Site Inspection Work Plan for Granite Mountain Radio Relay System
1994-09-01
represent field conditions, and (3) sampling results are repeatable. Final (04 WV---,,1-, ,W•, S 2, mbr . 19W4 13 RyCWed 1.5.2 Sample Handling Sample...procedures specified in Section 2.1.3. Samples collected from shallow depths will be obtained by submerging a stainless- steel, Teflon, or glass... submerged in a manner that minimizes agitation of sediment and the water sample. If a seep or spring has minimal discharge flow, gravel, boulders, and soil
Saylor, Karen L.; Anver, Miriam R.; Salomon, David S.; Golubeva, Yelena G.
2016-01-01
Laser capture microdissection (LCM) of tissue is an established tool in medical research for collection of distinguished cell populations under direct microscopic visualization for molecular analysis. LCM samples have been successfully analyzed in a number of genomic and proteomic downstream molecular applications. However, LCM sample collection and preparation procedure has to be adapted to each downstream analysis platform. In this present manuscript we describe in detail the adaptation of LCM methodology for the collection and preparation of fresh frozen samples for NanoString analysis based on a study of a model of mouse mammary gland carcinoma and its lung metastasis. Our adaptation of LCM sample preparation and workflow to the requirements of the NanoString platform allowed acquiring samples with high RNA quality. The NanoString analysis of such samples provided sensitive detection of genes of interest and their associated molecular pathways. NanoString is a reliable gene expression analysis platform that can be effectively coupled with LCM. PMID:27077656
Stenhouse, Gordon B.; Janz, David M.; Kapronczai, Luciene; Anne Erlenbach, Joy; Jansen, Heiko T.; Nelson, O. Lynne; Robbins, Charles T.; Boulanger, John
2017-01-01
Abstract Recognizing the potential value of steroid hormone measurements to augment non-invasive genetic sampling, we developed procedures based on enzyme-linked immunoassays to quantify reproductive steroid hormone concentrations in brown bear (Ursus arctos) hair. Then, using 94 hair samples collected from eight captive adult bears over a 2-year period, we evaluated (i) associations between hair concentrations of testosterone, progesterone, estradiol and cortisol; (ii) the effect of collecting by shaving vs. plucking; and (iii) the utility of reproductive hormone profiles to differentiate sex and reproductive state. Sample requirements (125 mg of guard hair) to assay all hormones exceeded amounts typically obtained by non-invasive sampling. Thus, broad application of this approach will require modification of non-invasive techniques to collect larger samples, use of mixed (guard and undercoat) hair samples and/or application of more sensitive laboratory procedures. Concentrations of hormones were highly correlated suggesting their sequestration in hair reflects underlying physiological processes. Marked changes in hair hormone levels during the quiescent phase of the hair cycle, coupled with the finding that progesterone concentrations, and their association with testosterone levels, differed markedly between plucked and shaved hair samples, suggests steroids sequestered in hair were likely derived from various sources, including skin. Changes in hair hormone concentrations over time, and in conjunction with key reproductive events, were similar to what has been reported concerning hormonal changes in the blood serum of brown bears. Thus, potential for the measurement of hair reproductive hormone levels to augment non-invasive genetic sampling appears compelling. Nonetheless, we are conducting additional validation studies on hair collected from free-ranging bears, representative of all sex, age and reproductive classes, to fully evaluate the utility of this approach for brown bear conservation and research. PMID:28580147
Sexual Abuse among Female High School Students in Istanbul, Turkey
ERIC Educational Resources Information Center
Alikasifoglu, Mujgan; Erginoz, Ethem; Ercan, Oya; Albayrak-Kaymak, Deniz; Uysal, Omer; Ilter, Ozdemir
2006-01-01
Objective: The objective of the study was to determine the prevalence of sexual abuse in female adolescents in Istanbul, Turkey from data collected as part of a school-based population study on health and health behaviors. Method: A stratified cluster sampling procedure was used for this cross-sectional study. The study sample included 1,955…
George E. Host; Carl W. Ramm; Eunice A. Padley; Kurt S. Pregitzer; James B. Hart; David T. Cleland
1992-01-01
Presents technical documentation for development of an Ecological Classification System for the Manistee National Forest in northwest Lower Michigan, and suggests procedures applicable to other ecological land classification projects. Includes discussion of sampling design, field data collection, data summarization and analyses, development of classification units,...
ERIC Educational Resources Information Center
Riccobono, John A.; Cominole, Melissa B.; Siegel, Peter H.; Gabel, Tim J.; Link, Michael W.; Berkner, Lutz K.
This report describes the methods and procedures used for the 2000 National Postsecondary Student Aid Study (NPSAS:2000). NPSAS:2000 included notable changes from previous NPSAS surveys (conducted in 1987, 1990, 1993, and 1996) in its sample design and collection of data. For example, this study is the first to restrict institutional sampling to…
The purpose of this SOP is to describe the in-field use of the particulate sampling system (pumping, control unit, and size selective inlet impactors) for collecting samples of particulate matter from the air during a predetermined time period during the Arizona NHEXAS project an...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bence, A.E.; Burns, W.A.
A procedure has been developed that discriminates Exxon Valdez crude from other sources of hydrocarbons found in Prince Williams Sound and the Gulf of Alaska. The procedure uses polycyclic aromatic hydrocarbon (PAH) distributions, measured by gas chromatography/mass spectrometry (GC/MS), to fingerprint sample extracts. The relative abundances of alkylated phenanthrenes, dibenzothiophenes, and chrysenes are used to differentiate Exxon Valdez crude and its weathering products from other hydrocarbons. Saturate fraction distributions are used to confirm the PAH identification whenever possible. The procedure has been applied to the more than 1,500 PAH analyses of tissues reported by the Oil Spill Health Task Force,more » formed after the spill to assess subsistence food safety, and nearly 4,700 PAH analyses of biological samples in PWSOIL, the government`s damage-assessment chemistry database. These two datasets constitute the largest collection of hydrocarbon analyses of biological samples form the spill-impact zone. 70 refs., 14 figs., 8 tabs.« less
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2006-01-01
The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance/quality-control data for the time period addressed in this report were stored in the laboratory's SAS data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality- control samples analyzed from July 1997 through June 1999. Results for the quality-control samples for 18 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration and (or) low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, total aluminum, ammonium, calcium, chloride, specific conductance, and sulfate. The data from the potassium and sodium analytical procedures are insufficient for evaluation. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 11 of 13 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. Blank analysis results for chloride showed that 22 percent of blanks did not meet data-quality objectives and results for dissolved organic carbon showed that 31 percent of the blanks did not meet data-quality objectives. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 14 of the 18 analytes. At least 90 percent of the samples met data-quality objectives for all analytes except total aluminum (70 percent of samples met objectives) and potassium (83 percent of samples met objectives). Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality for most constituents over the time period. The P-sample (low-ionic-strength constituents) analysis had good ratings in two of these studies and a satisfactory rating in the third. The results of the T-sample (trace constituents) analysis indicated high data quality with good ratings in all three studies. The N-sample (nutrient constituents) studies had one each of excellent, good, and satisfactory ratings. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 80 percent of the samples met data-quality objectives for 9 of the 13 analytes; the exceptions were dissolved organic carbon, ammonium, chloride, and specific conductance. Data-quality objectives were not met for dissolved organic carbon in two NWRI studies, but all of the samples were within control limits for the last study. Data-quality objectives were not met in 41 percent of samples analyzed for ammonium, 25 percent of samples analyzed for chloride, and 30 percent of samples analyzed for specific conductance. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 84 percent of the samples analyzed for calcium, chloride, magnesium, pH, and potassium. Data-quality objectives were met by 73 percent of those analyzed for sulfate. The data-quality objective was not met for sodium. The data are insufficient for evaluation of the specific conductance results.
A novel method for semen collection and artificial insemination in large parrots (Psittaciformes)
Lierz, Michael; Reinschmidt, Matthias; Müller, Heiner; Wink, Michael; Neumann, Daniel
2013-01-01
The paper described a novel technique for semen collection in large psittacines (patent pending), a procedure which was not routinely possible before. For the first time, a large set of semen samples is now available for analysis as well as for artificial insemination. Semen samples of more than 100 psittacine taxa were collected and analysed; data demonstrate large differences in the spermatological parameters between families, indicating an ecological relationship with breeding behaviour (polygamous versus monogamous birds). Using semen samples for artificial insemination resulted in the production of offspring in various families, such as Macaws and Cockatoos, for the first time ever. The present technique represents a breakthrough in species conservation programs and will enable future research into the ecology and environmental factors influencing endangered species. PMID:23797622
The purpose of this SOP is to describe the methods used to sample residential indoor and outdoor atmospheres for the presence of certain volatile organic compounds (VOCs) by means of absorption onto activated charcoal contained within a sampling badge. Activated charcoal diffusi...
Outcome-Dependent Sampling Design and Inference for Cox’s Proportional Hazards Model
Yu, Jichang; Liu, Yanyan; Cai, Jianwen; Sandler, Dale P.; Zhou, Haibo
2016-01-01
We propose a cost-effective outcome-dependent sampling design for the failure time data and develop an efficient inference procedure for data collected with this design. To account for the biased sampling scheme, we derive estimators from a weighted partial likelihood estimating equation. The proposed estimators for regression parameters are shown to be consistent and asymptotically normally distributed. A criteria that can be used to optimally implement the ODS design in practice is proposed and studied. The small sample performance of the proposed method is evaluated by simulation studies. The proposed design and inference procedure is shown to be statistically more powerful than existing alternative designs with the same sample sizes. We illustrate the proposed method with an existing real data from the Cancer Incidence and Mortality of Uranium Miners Study. PMID:28090134
This compendium includes method summaries provided by the Centers for Disease Control and Prevention/National Center for Environmental Health (CDC/NCEH) for collection and shipping of blood and urine samples for analysis of metals and volatile organic compounds (VOCs). It provide...
This compendium includes method summaries provided by the Centers for Disease Control and Prevention/National Center for Environmental Health (CDC/NCEH) for the collection and shipping of blood and urine samples for analysis of metals and volatile organic compounds (VOCs). It pro...
This compendium includes method summaries provided by the Centers for Disease Control and Prevention/National Center for Environmental Health (CDC/NCEH) for the collection and shipping of blood and urine samples for analysis of metals and volatile organic compounds (VOCs). It pro...
Heavy metals in atmospheric surrogate dry deposition
Morselli; Cecchini; Grandi; Iannuccilli; Barilli; Olivieri
1999-02-01
This paper describes a methodological approach for the assessment of the amount of surrogate dry deposition of several toxic heavy metals (Cd, Cr, Cu, Ni, Pb, V, Zn) associated with atmospheric particulate matter at ground level. The objectives of the study were twofold: i) the evaluation of several techniques for the digestion of dry deposition samples for trace metal analysis; ii) the comparison of the results from two samplers with different collecting surfaces. A dry solid surface sampler (DRY sampler, Andersen--USA) and a water layer surface sampler (DAS sampler--MTX Italy) were employed. The samples were collected over a one-year period in an urban site of Bologna (northern Italy). A description is given of the complete procedure, from sampling to data elaboration, including sample storage, digestion and analytical methods. According to the results obtained with three different digestion techniques (Teflon bomb, microwave digester and Teflon flask with vapour cooling system), the highest recovery rate was achieved by the Teflon bomb procedure employing an NBS 1648 Standard Reference Material; 90-95% of the elements considered were recovered by dissolution in a pressurized Teflon bomb with an HNO3-HF mixture. Given these results, the technique was adopted for dry deposition sample digestion. On the basis of the amount of heavy metals measured as monthly deposition fluxes (microg/m2), the collecting efficiency of the DAS sampler for a number of elements was found to be as much as two to three times greater than that of the DRY sampler.
Collecting Samples for Testing
... one or more hours to avoid a potential post-test spinal headache. The lumbar puncture procedure usually takes ... View sources NOTE: This article is based on research that ... of the Lab Tests Online Editorial Review Board . This article is periodically ...
Detection of septicemia in chicken livers by spectroscopy,.
Dey, B P; Chen, Y R; Hsieh, C; Chan, D E
2003-02-01
To establish a procedure for differentiating normal chickens from chickens with septicemia/toxemia (septox) by machine inspection under the Hazard Analysis and Critical Control Point-Based Inspection Models Project, spectral measurements of 300 chicken livers, of which half were normal and half were condemned due to septox conditions, were collected and analyzed. Neural network classification of the spectral data after principal component analysis (PCA) indicated that normal and septox livers were correctly differentiated by spectroscopy at a rate of 96%. Analysis of the data established 100% correlation between the spectroscopic identification and the subset of samples, both normal and septox, that were histopathologically diagnosed. In an attempt to establish the microbiological etiology of the diseased livers, isolates from 30 livers indicated that the poultry carcasses were contaminated mostly with coliforms present in the environment, hindering the isolation of pathogenic microorganisms. Therefore, to establish the cause of diseased livers, a strictly aseptic environment and procedure for sample collection is required.
Sawant, Pramilla D; Kumar, Suja Arun; Wankhede, Sonal; Rao, D D
2018-06-01
In-vitro bioassay monitoring generally involves analysis of overnight urine samples (~12 h) collected from radiation workers to estimate the excretion rate of radionuclides from the body. The unknown duration of sample collection (10-16 h) adds to the overall uncertainty in computation of internal dose. In order to minimize this, IAEA recommends measurement of specific gravity or creatinine excretion rate in urine. Creatinine is excreted at a steady rate with normally functioning kidneys therefore, can be used as a normalization factor to infer the duration of collection and/or dilution of the sample, if any. The present study reports the chemical procedure standardized and its application for the estimation of creatinine as well as creatinine co-efficient in normal healthy individuals. Observations indicate higher inter-subject variability and lower constancy in daily excretion of creatinine for the same subject. Thus creatinine excretion rate may not be a useful indicator for extrapolating to 24 h sample collection. Copyright © 2018 Elsevier Ltd. All rights reserved.
Sato, Yuka; Seimiya, Masanori; Yoshida, Toshihiko; Sawabe, Yuji; Hokazono, Eisaku; Osawa, Susumu; Matsushita, Kazuyuki
2017-01-01
Background The indocyanine green retention rate is important for assessing the severity of liver disorders. In the conventional method, blood needs to be collected twice. In the present study, we developed an automated indocyanine green method that does not require blood sampling before intravenous indocyanine green injections and is applicable to an automated biochemical analyser. Methods The serum samples of 471 patients collected before and after intravenous indocyanine green injections and submitted to the clinical laboratory of our hospital were used as samples. The standard procedure established by the Japan Society of Hepatology was used as the standard method. In the automated indocyanine green method, serum collected after an intravenous indocyanine green injection was mixed with the saline reagent containing a surfactant, and the indocyanine green concentration was measured at a dominant wavelength of 805 nm and a complementary wavelength of 884 nm. Results The coefficient of variations of the within- and between-run reproducibilities of this method were 2% or lower, and dilution linearity passing the origin was noted up to 10 mg/L indocyanine green. The reagent was stable for four weeks or longer. Haemoglobin, bilirubin and chyle had no impact on the results obtained. The correlation coefficient between the standard method (x) and this method (y) was r=0.995; however, slight divergence was noted in turbid samples. Conclusion Divergence in turbid samples may have corresponded to false negativity with the standard procedure. Our method may be highly practical because blood sampling before indocyanine green loading is unnecessary and measurements are simple.
NASA Technical Reports Server (NTRS)
Sams, Clarence; Crucian, Brian; Stowe, Raymond; Pierson, Duane; Mehta, Satish; Morukov, Boris; Uchakin, Peter; Nehlsen-Cannarella, Sandra
2008-01-01
Validation of Procedures for Monitoring Crew Member Immune Function - Short Duration Biological Investigation (Integrated Immune-SDBI) will assess the clinical risks resulting from the adverse effects of space flight on the human immune system and will validate a flightcompatible immune monitoring strategy. Immune system changes will be monitored by collecting and analyzing blood, urine and saliva samples from crewmembers before, during and after space flight.
1984-08-01
8 3. Water-quality, sediment, and biological parameters, associated units, EPA STORET codes, container type, 0 preservative and methods used for...Section III.B). Water samples were collected and preserved according to * _ approved EPA (1974) or American Public Health Association (APHA) (1975...procedures. Water-quality parameters tested, associated units, EPA STORET codes, test procedures, and preservation tech- niques used throughout the
Dagostino, Concetta; De Gregori, Manuela; Gieger, Christian; Manz, Judith; Gudelj, Ivan; Lauc, Gordan; Divizia, Laura; Wang, Wei; Sim, Moira; Pemberton, Iain K; MacDougall, Jane; Williams, Frances; Van Zundert, Jan; Primorac, Dragan; Aulchenko, Yurii; Kapural, Leonardo; Allegri, Massimo
2017-01-01
Chronic low back pain (CLBP) is one of the most common medical conditions, ranking as the greatest contributor to global disability and accounting for huge societal costs based on the Global Burden of Disease 2010 study. Large genetic and -omics studies provide a promising avenue for the screening, development and validation of biomarkers useful for personalized diagnosis and treatment (precision medicine). Multicentre studies are needed for such an effort, and a standardized and homogeneous approach is vital for recruitment of large numbers of participants among different centres (clinical and laboratories) to obtain robust and reproducible results. To date, no validated standard operating procedures (SOPs) for genetic/-omics studies in chronic pain have been developed. In this study, we validated an SOP model that will be used in the multicentre (5 centres) retrospective "PainOmics" study, funded by the European Community in the 7th Framework Programme, which aims to develop new biomarkers for CLBP through three different -omics approaches: genomics, glycomics and activomics. The SOPs describe the specific procedures for (1) blood collection, (2) sample processing and storage, (3) shipping details and (4) cross-check testing and validation before assays that all the centres involved in the study have to follow. Multivariate analysis revealed the absolute specificity and homogeneity of the samples collected by the five centres for all genetics, glycomics and activomics analyses. The SOPs used in our multicenter study have been validated. Hence, they could represent an innovative tool for the correct management and collection of reliable samples in other large-omics-based multicenter studies.
Gómez Román, Victor Raúl; Vinner, Lasse; Grevstad, Berit; Hansen, Jesper Juhl; Wegmann, Frank; Spetz, Anna-Lena; Fomsgaard, Anders
2010-12-15
The New Zealand white rabbit model (Oryctolagus cuniculus) is widely used to test whether HIV vaccine candidates elicit systemic antibody responses; however, its use in mucosal immunology has not been fully exploited due to the difficulty in collecting mucosal specimens longitudinally and reproducibly. Here we describe feasible and non-feasible methods to collect vaginal and nasal specimens from nulliparous rabbits. Non-feasible methods were those resulting in poor reproducibility and considerable animal twitching during sampling, whereas feasible methods resulted in no animal twitching and potential for sampling reproducibility. Standard operating procedures (SOPs) were implemented to collect vaginal swabs yielding total IgA titres ranging from 12,500 to 312,500. Intranasal immunisation with a naked DNA vaccine encoding HIV gp140 elicited HIV envelope-specific IgA detectable in nasal but not in vaginal secretions. Our methods provide an alternative to reliably assess pre- and post-vaccination mucosal antibody titres longitudinally in rabbits as part of mucosal HIV vaccine immunogenicity studies. Copyright © 2010 Elsevier B.V. All rights reserved.
Concentration of gold in natural waters
McHugh, J.B.
1988-01-01
The purpose of this paper is to investigate the amount of gold present in natural waters. One hundred and thirty-two natural water samples were collected from various sources and analyzed for gold by the latest techniques. Background values for gold in natural waters range from <0.001 to 0.005 ppb, and anomalous values range from 0.010 to 2.8 ppb. Waters collected from mineralized areas have a mean gold value of 0.101 ppb, whereas waters collected from unmineralized areas have a mean of 0.002 ppb. Some of the high gold values reported in the earlier literature were probably due to interferences by high salt content in the sample and/or lack of proper filter procedures. ?? 1988.
McDade, Thomas W; Williams, Sharon; Snodgrass, J Josh
2007-11-01
Logistical constraints associated with the collection and analysis of biological samples in community-based settings have been a significant impediment to integrative, multilevel bio-demographic and biobehavioral research. However recent methodological developments have overcome many of these constraints and have also expanded the options for incorporating biomarkers into population-based health research in international as well as domestic contexts. In particular using dried blood spot (DBS) samples-drops of whole blood collected on filter paper from a simple finger prick-provides a minimally invasive method for collecting blood samples in nonclinical settings. After a brief discussion of biomarkers more generally, we review procedures for collecting, handling, and analyzing DBS samples. Advantages of using DBS samples-compared with venipuncture include the relative ease and low cost of sample collection, transport, and storage. Disadvantages include requirements for assay development and validation as well as the relatively small volumes of sample. We present the results of a comprehensive literature review of published protocols for analysis of DBS samples, and we provide more detailed analysis of protocols for 45 analytes likely to be of particular relevance to population-level health research. Our objective is to provide investigators with the information they need to make informed decisions regarding the appropriateness of blood spot methods for their research interests.
A new tool for the evaluation of the analytical procedure: Green Analytical Procedure Index.
Płotka-Wasylka, J
2018-05-01
A new means for assessing analytical protocols relating to green analytical chemistry attributes has been developed. The new tool, called GAPI (Green Analytical Procedure Index), evaluates the green character of an entire analytical methodology, from sample collection to final determination, and was created using such tools as the National Environmental Methods Index (NEMI) or Analytical Eco-Scale to provide not only general but also qualitative information. In GAPI, a specific symbol with five pentagrams can be used to evaluate and quantify the environmental impact involved in each step of an analytical methodology, mainly from green through yellow to red depicting low, medium to high impact, respectively. The proposed tool was used to evaluate analytical procedures applied in the determination of biogenic amines in wine samples, and polycyclic aromatic hydrocarbon determination by EPA methods. GAPI tool not only provides an immediately perceptible perspective to the user/reader but also offers exhaustive information on evaluated procedures. Copyright © 2018 Elsevier B.V. All rights reserved.
Bonaduce, Ilaria; Brecoulaki, Hariclia; Colombini, Maria Perla; Lluveras, Anna; Restivo, Vincenzo; Ribechini, Erika
2007-12-21
This paper presents an analytical GC-MS procedure to study the chemical composition of plant gums, determining aldoses and uronic acids in one step. The procedure is based on the silylation of aldoses and uronic acids, released from plant gums by microwave assisted hydrolysis, and previously converted into the corresponding diethyl-dithioacetals and diethyl-dithioacetal lactones. Using this method only one peak for each compound is obtained, thus providing simple and highly reproducible chromatograms. The analytical procedure was optimised using reference samples of raw plant gums (arabic, karaya, ghatti, guar, locust bean and tragacanth, cherry, plum and peach gums), commercial watercolours and paint layers prepared according to ancient recipes at the Opificio delle Pietre Dure of Florence (Italy). To identify gum media in samples of unknown composition, a decisional schema for the gum identification and the principal component analysis of the relative sugar percentage contents were employed. The procedure was used to study samples collected from wall paintings from Macedonian tombs (4th-3rd centuries bc) and from the Mycenaean "Palace of Nestor" (13th century bc) in Pylos, Greece. The presence of carbohydrates was ascertained and plant gum binders (fruit and a mixture of tragacanth and fruit tree gums) were identified in some of the samples.
DOE Office of Scientific and Technical Information (OSTI.GOV)
LaFreniere, Lorraine M.
In March 2009, the CCC/USDA developed a plan for annual monitoring of the groundwater and surface water (Argonne 2009). Under this plan, approved by the KDHE (2009), monitoring wells are sampled by using the low-flow procedure (Puls and Barcelona 1996; Yeskis and Zavala 2002), and surface water samples are collected at five locations along the intermittent creek. Vegetation sampling is conducted as a secondary indicator of plume migration. As of 2015, the frequency of surface water sampling has been decreased to once yearly, per the approval of the KDHE (2015).
Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2012-10-24
This plan incorporates U.S. Department of Energy (DOE) Office of Legacy Management (LM) standard operating procedures (SOPs) into environmental monitoring activities and will be implemented at all sites managed by LM. This document provides detailed procedures for the field sampling teams so that samples are collected in a consistent and technically defensible manner. Site-specific plans (e.g., long-term surveillance and maintenance plans, environmental monitoring plans) document background information and establish the basis for sampling and monitoring activities. Information will be included in site-specific tabbed sections to this plan, which identify sample locations, sample frequencies, types of samples, field measurements, and associatedmore » analytes for each site. Additionally, within each tabbed section, program directives will be included, when developed, to establish additional site-specific requirements to modify or clarify requirements in this plan as they apply to the corresponding site. A flowchart detailing project tasks required to accomplish routine sampling is displayed in Figure 1. LM environmental procedures are contained in the Environmental Procedures Catalog (LMS/PRO/S04325), which incorporates American Society for Testing and Materials (ASTM), DOE, and U.S. Environmental Protection Agency (EPA) guidance. Specific procedures used for groundwater and surface water monitoring are included in Appendix A. If other environmental media are monitored, SOPs used for air, soil/sediment, and biota monitoring can be found in the site-specific tabbed sections in Appendix D or in site-specific documents. The procedures in the Environmental Procedures Catalog are intended as general guidance and require additional detail from planning documents in order to be complete; the following sections fulfill that function and specify additional procedural requirements to form SOPs. Routine revision of this Sampling and Analysis Plan will be conducted annually at the beginning of each fiscal year when attachments in Appendix D, including program directives and sampling location/analytical tables, will be reviewed by project personnel and updated. The sampling location/analytical tables in Appendix D, however, may have interim updates according to project direction that are not reflected in this plan. Deviations from location/analytical tables in Appendix D prior to sampling will be documented in project correspondence (e.g., startup letters). If significant changes to other aspects of this plan are required before the annual update, then the plan will be revised as needed.« less
Ryan Clarke, P; Frey, Rebecca K; Rhyan, Jack C; McCollum, Matt P; Nol, Pauline; Aune, Keith
2014-03-01
OBJECTIVE--To determine the feasibility of qualifying individuals or groups of Yellowstone National Park bison as free from brucellosis. DESIGN--Cohort study. SAMPLE--Serum, blood, and various samples from live bison and tissues taken at necropsy from 214 bison over 7 years. PROCEDURES--Blood was collected from bison every 30 to 45 days for serologic tests and microbiological culture of blood for Brucella abortus. Seropositive bison were euthanized until all remaining bison had 2 consecutive negative test results. Half the seronegative bison were randomly euthanized, and tissues were collected for bacteriologic culture. The remaining seronegative bison were bred, and blood was tested at least twice per year. Cow-calf pairs were sampled immediately after calving and 6 months after calving for evidence of B abortus. RESULTS--Post-enrollment serial testing for B abortus antibodies revealed no bison that seroconverted after 205 days (first cohort) and 180 days (second cohort). During initial serial testing, 85% of bison seroconverted within 120 days after removal from the infected population. Brucella abortus was not cultured from any euthanized seronegative bison (0/88). After parturition, no cows or calves had a positive test result for B abortus antibodies, nor was B abortus cultured from any samples. CONCLUSIONS AND CLINICAL RELEVANCE--Results suggested it is feasible to qualify brucellosis-free bison from an infected herd following quarantine procedures as published in the USDA APHIS brucellosis eradication uniform methods and rules. Latent infection was not detected in this sample of bison when applying the USDA APHIS quarantine protocol.
Americium-241 in surface soil associated with the Hanford site and vicinity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Price, K.R.; Gilbert, R.O.; Gano, K.A.
1981-05-01
Various kinds of surface soil samples were collected and analyzed for Americium-241 (/sup 241/Am) to examine the feasibility of improving soil sample data for the Hanford Surface Environmental Surveillance Program. Results do not indicate that a major improvement would occur if procedures were changed from the current practices. Conclusions from this study are somewhat tempered by the very low levels of /sup 241/Am (< 0.10 pCi/g dry weight) detected in surface soil samples and by the fact that statistical significance depended on the type of statistical tests used. In general, the average concentration of /sup 241/Am in soil crust (0more » to 1.0 cm deep) was greater than the corresponding subsurface layer (1.0 to 2.5 cm deep), and the average concentration of /sup 241/Am in some onsite samples collected near the PUREX facility was greater than comparable samples collected 60 km upwind at an offsite location.« less
Patrick, Hannah; Sims, Andrew; Burn, Julie; Bousfield, Derek; Colechin, Elaine; Reay, Christopher; Alderson, Neil; Goode, Stephen; Cunningham, David; Campbell, Bruce
2013-03-01
New devices and procedures are often introduced into health services when the evidence base for their efficacy and safety is limited. The authors sought to assess the availability and accuracy of routinely collected Hospital Episodes Statistics (HES) data in the UK and their potential contribution to the monitoring of new procedures. Four years of HES data (April 2006-March 2010) were analysed to identify episodes of hospital care involving a sample of 12 new interventional procedures. HES data were cross checked against other relevant sources including national or local registers and manufacturers' information. HES records were available for all 12 procedures during the entire study period. Comparative data sources were available from national (5), local (2) and manufacturer (2) registers. Factors found to affect comparisons were miscoding, alternative coding and inconsistent use of subsidiary codes. The analysis of provider coverage showed that HES is sensitive at detecting centres which carry out procedures, but specificity is poor in some cases. Routinely collected HES data have the potential to support quality improvements and evidence-based commissioning of devices and procedures in health services but achievement of this potential depends upon the accurate coding of procedures.
High School and Beyond Transcripts Survey (1982). Data File User's Manual. Contractor Report.
ERIC Educational Resources Information Center
Jones, Calvin; And Others
This data file user's manual documents the procedures used to collect and process high school transcripts for a large sample of the younger cohort (1980 sophomores) in the High School and Beyond survey. The manual provides the user with the technical assistance needed to use the computer file and also discusses the following: (1) sample design for…
40 CFR 86.160-00 - Exhaust emission test procedure for SC03 emissions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2, CH4, and NOX. (b) Dynamometer activities. (1) All...
40 CFR 86.160-00 - Exhaust emission test procedure for SC03 emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2, CH4, and NOX. (b) Dynamometer activities. (1) All...
40 CFR 86.160-00 - Exhaust emission test procedure for SC03 emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2, CH4, and NOX. (b) Dynamometer activities. (1) All...
The purpose of this SOP is to describe the methods used to sample residential indoor and outdoor atmospheres for the presence of formaldehyde using the PF-1 passive formaldehyde sampler. The PF-1 passive sampler is used as a fixed location monitor to determine time integrated ex...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holladay, S.K.; Anderson, H.M.; Benson, S.B.
Quality assurance (QA) objectives for Phase 2 were that (1) scientific data generated would withstand scientific and legal scrutiny; (2) data would be gathered using appropriate procedures for sample collection, sample handling and security, chain of custody, laboratory analyses, and data reporting; (3) data would be of known precision and accuracy; and (4) data would meet data quality objectives defined in the Phase 2 Sampling and Analysis Plan. A review of the QA systems and quality control (QC) data associated with the Phase 2 investigation is presented to evaluate whether the data were of sufficient quality to satisfy Phase 2more » objectives. The data quality indicators of precision, accuracy, representativeness, comparability, completeness, and sensitivity were evaluated to determine any limitations associated with the data. Data were flagged with qualifiers that were associated with appropriate reason codes and documentation relating the qualifiers to the reviewer of the data. These qualifiers were then consolidated into an overall final qualifier to represent the quality of the data to the end user. In summary, reproducible, precise, and accurate measurements consistent with CRRI objectives and the limitations of the sampling and analytical procedures used were obtained for the data collected in support of the Phase 2 Remedial Investigation.« less
Human breath metabolomics using an optimized noninvasive exhaled breath condensate sampler
Zamuruyev, Konstantin O.; Aksenov, Alexander A.; Pasamontes, Alberto; Brown, Joshua F.; Pettit, Dayna R.; Foutouhi, Soraya; Weimer, Bart C.; Schivo, Michael; Kenyon, Nicholas J.; Delplanque, Jean-Pierre; Davis, Cristina E.
2017-01-01
Exhaled breath condensate (EBC) analysis is a developing field with tremendous promise to advance personalized, non-invasive health diagnostics as new analytical instrumentation platforms and detection methods are developed. Multiple commercially-available and researcher-built experimental samplers are reported in the literature. However, there is very limited information available to determine an effective breath sampling approach, especially regarding the dependence of breath sample metabolomic content on the collection device design and sampling methodology. This lack of an optimal standard procedure results in a range of reported results that are sometimes contradictory. Here, we present a design of a portable human EBC sampler optimized for collection and preservation of the rich metabolomic content of breath. The performance of the engineered device is compared to two commercially available breath collection devices: the RTube™ and TurboDECCS. A number of design and performance parameters are considered, including: condenser temperature stability during sampling, collection efficiency, condenser material choice, and saliva contamination in the collected breath samples. The significance of the biological content of breath samples, collected with each device, is evaluated with a set of mass spectrometry methods and was the primary factor for evaluating device performance. The design includes an adjustable mass-size threshold for aerodynamic filtering of saliva droplets from the breath flow. Engineering an inexpensive device that allows efficient collection of metalomic-rich breath samples is intended to aid further advancement in the field of breath analysis for non-invasive health diagnostic. EBC sampling from human volunteers was performed under UC Davis IRB protocol 63701-3 (09/30/2014-07/07/2017). PMID:28004639
Human breath metabolomics using an optimized non-invasive exhaled breath condensate sampler.
Zamuruyev, Konstantin O; Aksenov, Alexander A; Pasamontes, Alberto; Brown, Joshua F; Pettit, Dayna R; Foutouhi, Soraya; Weimer, Bart C; Schivo, Michael; Kenyon, Nicholas J; Delplanque, Jean-Pierre; Davis, Cristina E
2016-12-22
Exhaled breath condensate (EBC) analysis is a developing field with tremendous promise to advance personalized, non-invasive health diagnostics as new analytical instrumentation platforms and detection methods are developed. Multiple commercially-available and researcher-built experimental samplers are reported in the literature. However, there is very limited information available to determine an effective breath sampling approach, especially regarding the dependence of breath sample metabolomic content on the collection device design and sampling methodology. This lack of an optimal standard procedure results in a range of reported results that are sometimes contradictory. Here, we present a design of a portable human EBC sampler optimized for collection and preservation of the rich metabolomic content of breath. The performance of the engineered device is compared to two commercially available breath collection devices: the RTube ™ and TurboDECCS. A number of design and performance parameters are considered, including: condenser temperature stability during sampling, collection efficiency, condenser material choice, and saliva contamination in the collected breath samples. The significance of the biological content of breath samples, collected with each device, is evaluated with a set of mass spectrometry methods and was the primary factor for evaluating device performance. The design includes an adjustable mass-size threshold for aerodynamic filtering of saliva droplets from the breath flow. Engineering an inexpensive device that allows efficient collection of metalomic-rich breath samples is intended to aid further advancement in the field of breath analysis for non-invasive health diagnostic. EBC sampling from human volunteers was performed under UC Davis IRB protocol 63701-3 (09/30/2014-07/07/2017).
NASA Astrophysics Data System (ADS)
See, Randolph B.; Schroder, LeRoy J.; Willoughby, Timothy C.
A continuing quality-assurance program has been operated by the U.S. Geological Survey to evaluate any bias introduced by routine handling, shipping, and laboratory analyses of wet-deposition samples collected in the National Atmospheric Deposition Program (NADP) and National Trends Network (NTN). Blind-audit samples having a variety of constituent concentrations and values were selected. Only blind-audit samples with constituent concentrations and values less than the 95th-percentile concentration for natural wet-deposition samples were included in the analysis. Of the major ions, there was a significant increase of Ca 2+, Mg 2+, Na 2+, K +, SO 42- and Cl -1 in samples handled according to standard protocols and shipped in NADP/NTN sample-collection buckets. For 1979-1987, graphs of smoothed data showing the estimated contamination in blind-audit samples indicate a decrease in the median concentration and ranges of Ca 2+, Mg 2+ and SO 42- contamination of blind-audit samples shipped in sample-collection buckets. Part of the contamination detected in blind-audit samples can be attributed to contact with the sample-collection bucket and lid; however, additional sources also seem to contaminate the blind-audit sample. Apparent decreases in the magnitude and range of sample contamination may be caused by differences in sample-collection bucket- and lid-washing procedures by the NADP/NTN Central Analytical Laboratory. Although the degree of bias is minimal for most constituents, summaries of the NADP/NTN data base may contain overestimates of Ca 2+, Mg 2+, Na -, K + and SO 42- and Cl - concentrations, and underestimates of H + concentrations.
See, R.B.; Schroder, L.J.; Willoughby, T.C.
1989-01-01
A continuing quality-assurance program has been operated by the U.S. Geographical Survey to evaluate any bias introduced by routine handling, shipping, and laboratory analyses of wet-deposition samples collected in the National Atmospheric Deposition Program (NADP) and National Trends Network (NTN). Blind-audit samples having a variety of constituent concentrations and values were selected. Only blind-audit samples with constituent concentrations and values less than the 95th-percentile concentration for natural wet-deposition samples were included in the analysis. Of the major ions, there was a significant increase of Ca2+, Mg2+, K+ SO42+ and Cl- in samples handled according to standard protocols and shipped in NADP/NTN sample-collection buckets. For 1979-1987, graphs of smoothed data showing the estimated contaminations in blind-audit samples indicate a decrease in the median concentration and ranges of Ca2+, Mg2+ and SO42- contamination of blind-audit samples shipped in sample-collection buckets. Part of the contamination detected in blind-audit samples can be attributed to contact with the sample-collection bucket and lid; however, additional sources also seem to contaminate the blind-audit sample. Apparent decreases in the magnitude and range of sample contamination may be caused by differences in sample-collection bucket- and lid-washing procedures by the NADP/NTN Central Analytical Laboratory. Although the degree of bias is minimal for most constituents, summaries of the NADP/NTN data base may contain overestimates of Ca2+, Mg2+, Na-, K+, SO42- and Cl- concentrations, and underestimates of H+ concentrations.
Tale of two sites: capillary versus arterial blood glucose testing in the operating room.
Akinbami, Felix; Segal, Scott; Schnipper, Jeffrey L; Stopfkuchen-Evans, Matthias; Mills, Jonathan; Rogers, Selwyn O
2012-04-01
Pre- and intraoperative glycemic control has been identified as a putative target to improve outcomes of surgical patients. Glycemic control requires frequent monitoring of blood glucose levels with appropriate adjustments. However, monitoring standards have been called into question, especially in cases in which capillary samples are used. Point-of-care testing (POCT) using capillary samples and glucometers has been noted to give relatively accurate results for critically ill patients. However, the package inserts of most glucometers warn that they should not be used for patients in shock. This has led clinicians to doubt their accuracy in the operating room. The accuracy of capillary samples when tested in patients undergoing surgical procedures has not been proven. This study aims to determine the accuracy of intraoperative blood glucose values using capillary samples relative to arterial samples. A prospective study was conducted by collecting paired capillary and arterial samples of patients undergoing major operations at a tertiary medical center from August 2009 to May 2011. Subjects were a convenience sample of patients who had arterial lines and needed glucose testing while undergoing the procedure. Precision Xceed Pro (Abbott) handheld glucometers were used to obtain the blood glucose values. Our primary outcome of interest was the degree of correlation between capillary and arterial blood glucose values or the degree to which arterial glucose levels can be predicted by capillary glucose samples. We used linear regression and the Student t tests for statistical analyses. Seventy-two-paired samples were collected. Of the cases, 54% were major abdominal operations, whereas 24% were vascular operations. The mean values ± standard deviation for glucose levels were 146 ± 35 mg/dL (capillary) and 147 ± 36 mg/dL (arterial). The mean time ± standard deviation between the collection of both samples was 3.5 ± 1.3 minutes. The regression coefficient showed a strong positive correlation of .91 between capillary glucose values and arterial values (P < .001) although correlation was less stringent at the hyperglycemic range of values. The R(2) statistic was 84%. Differences in values between capillary and arterial samples would not have altered the diagnosis of hypo- and hyperglycemia using typical thresholds. Capillary samples collected intraoperatively are strongly correlated with arterial samples. Glucose monitoring in the operating room can be safely performed by collecting capillary samples for POCT. However, clinicians should still be cautious when interpreting glucose levels that are high, either by repeating the blood glucose test or by having samples sent to the laboratory. Copyright © 2012 Elsevier Inc. All rights reserved.
Cumulative uncertainty in measured streamflow and water quality data for small watersheds
Harmel, R.D.; Cooper, R.J.; Slade, R.M.; Haney, R.L.; Arnold, J.G.
2006-01-01
The scientific community has not established an adequate understanding of the uncertainty inherent in measured water quality data, which is introduced by four procedural categories: streamflow measurement, sample collection, sample preservation/storage, and laboratory analysis. Although previous research has produced valuable information on relative differences in procedures within these categories, little information is available that compares the procedural categories or presents the cumulative uncertainty in resulting water quality data. As a result, quality control emphasis is often misdirected, and data uncertainty is typically either ignored or accounted for with an arbitrary margin of safety. Faced with the need for scientifically defensible estimates of data uncertainty to support water resource management, the objectives of this research were to: (1) compile selected published information on uncertainty related to measured streamflow and water quality data for small watersheds, (2) use a root mean square error propagation method to compare the uncertainty introduced by each procedural category, and (3) use the error propagation method to determine the cumulative probable uncertainty in measured streamflow, sediment, and nutrient data. Best case, typical, and worst case "data quality" scenarios were examined. Averaged across all constituents, the calculated cumulative probable uncertainty (??%) contributed under typical scenarios ranged from 6% to 19% for streamflow measurement, from 4% to 48% for sample collection, from 2% to 16% for sample preservation/storage, and from 5% to 21% for laboratory analysis. Under typical conditions, errors in storm loads ranged from 8% to 104% for dissolved nutrients, from 8% to 110% for total N and P, and from 7% to 53% for TSS. Results indicated that uncertainty can increase substantially under poor measurement conditions and limited quality control effort. This research provides introductory scientific estimates of uncertainty in measured water quality data. The results and procedures presented should also assist modelers in quantifying the "quality"of calibration and evaluation data sets, determining model accuracy goals, and evaluating model performance.
This compendium includes method summaries provided by the Centers for Disease Control and Prevention/National Center for Environmental Health (CDC/NCEH) for the collection and shipping of blood and urine samples for analysis of metals and volatile organic compounds (VOCs). The pr...
Donald C. Buso; Gene E. Likens; John S. Eaton
2000-01-01
The Hubbard Brook Ecosystem Study (HBES), begun in 1963, is a long-term effort to understand the structure, function and change in forest watersheds and associated aquatic ecosystems at the Hubbard Brook Experimental Forest in New Hampshire. Chemical analyses of streamwater and precipitation collections began in 1963, and analyses of lakewater collections began in 1967...
A new procedure for extraction of collagen from modern and archaeological bones for 14C dating.
Maspero, F; Sala, S; Fedi, M E; Martini, M; Papagni, A
2011-10-01
Bones are potentially the best age indicators in a stratigraphic study, because they are closely related to the layer in which they are found. Collagen is the most suitable fraction and is the material normally used in radiocarbon dating. Bone contaminants can strongly alter the carbon isotopic fraction values of the samples, so chemical pretreatment for (14)C dating by accelerator mass spectrometry (AMS) is essential. The most widespread method for collagen extraction is based on the Longin procedure, which consists in HCl demineralization to dissolve the inorganic phase of the samples, followed by dissolution of collagen in a weak acid solution. In this work the possible side effects of this procedure on a modern bone are presented; the extracted collagen was analyzed by ATR-IR spectroscopy. An alternative procedure, based on use of HF instead of HCl, to minimize unwanted degradation of the organic fraction, is also given. A study by ATR-IR spectroscopic analysis of collagen collected after different demineralization times and with different acid volumes, and a study of an archaeological sample, are also presented.
NASA Astrophysics Data System (ADS)
Beddow, B.; Roberts, C.; Rankin, J.; Bloch, A.; Peizer, J.
1981-01-01
The National Accident Sampling System (NASS) is described. The study area discussed is one of the original ten sites selected for NASS implementation. In addition to collecting data from the field, the original ten sites address questions of feasibility of the plan, projected results of the data collection effort, and specific operational topics, e.g., team size, sampling requirements, training approaches, quality control procedures, and field techniques. Activities and results of the first three years of the project, for both major tasks (establishment and operation) are addressed. Topics include: study area documentation; team description, function and activities; problems and solutions; and recommendations.
2012-01-01
Background Saccharide materials have been used for centuries as binding media, to paint, write and illuminate manuscripts and to apply metallic leaf decorations. Although the technical literature often reports on the use of plant gums as binders, actually several other saccharide materials can be encountered in paint samples, not only as major binders, but also as additives. In the literature, there are a variety of analytical procedures that utilize GC-MS to characterize saccharide materials in paint samples, however the chromatographic profiles are often extremely different and it is impossible to compare them and reliably identify the paint binder. Results This paper presents a comparison between two different analytical procedures based on GC-MS for the analysis of saccharide materials in works-of-art. The research presented here evaluates the influence of the analytical procedure used, and how it impacts the sugar profiles obtained from the analysis of paint samples that contain saccharide materials. The procedures have been developed, optimised and systematically used to characterise plant gums at the Getty Conservation Institute in Los Angeles, USA (GCI) and the Department of Chemistry and Industrial Chemistry of the University of Pisa, Italy (DCCI). The main steps of the analytical procedures and their optimisation are discussed. Conclusions The results presented highlight that the two methods give comparable sugar profiles, whether the samples analysed are simple raw materials, pigmented and unpigmented paint replicas, or paint samples collected from hundreds of centuries old polychrome art objects. A common database of sugar profiles of reference materials commonly found in paint samples was thus compiled. The database presents data also from those materials that only contain a minor saccharide fraction. This database highlights how many sources of saccharides can be found in a paint sample, representing an important step forward in the problem of identifying polysaccharide binders in paint samples. PMID:23050842
Lluveras-Tenorio, Anna; Mazurek, Joy; Restivo, Annalaura; Colombini, Maria Perla; Bonaduce, Ilaria
2012-10-10
Saccharide materials have been used for centuries as binding media, to paint, write and illuminate manuscripts and to apply metallic leaf decorations. Although the technical literature often reports on the use of plant gums as binders, actually several other saccharide materials can be encountered in paint samples, not only as major binders, but also as additives. In the literature, there are a variety of analytical procedures that utilize GC-MS to characterize saccharide materials in paint samples, however the chromatographic profiles are often extremely different and it is impossible to compare them and reliably identify the paint binder. This paper presents a comparison between two different analytical procedures based on GC-MS for the analysis of saccharide materials in works-of-art. The research presented here evaluates the influence of the analytical procedure used, and how it impacts the sugar profiles obtained from the analysis of paint samples that contain saccharide materials. The procedures have been developed, optimised and systematically used to characterise plant gums at the Getty Conservation Institute in Los Angeles, USA (GCI) and the Department of Chemistry and Industrial Chemistry of the University of Pisa, Italy (DCCI). The main steps of the analytical procedures and their optimisation are discussed. The results presented highlight that the two methods give comparable sugar profiles, whether the samples analysed are simple raw materials, pigmented and unpigmented paint replicas, or paint samples collected from hundreds of centuries old polychrome art objects. A common database of sugar profiles of reference materials commonly found in paint samples was thus compiled. The database presents data also from those materials that only contain a minor saccharide fraction. This database highlights how many sources of saccharides can be found in a paint sample, representing an important step forward in the problem of identifying polysaccharide binders in paint samples.
Amendment to examination and investigation sample requirements--FDA. Direct final rule.
1998-09-25
The Food and Drug Administration (FDA) is amending its regulations regarding the collection of twice the quantity of food, drug, or cosmetic estimated to be sufficient for analysis. This action increases the dollar amount that FDA will consider to determine whether to routinely collect a reserve sample of a food, drug, or cosmetic product in addition to the quantity sufficient for analysis. Experience has demonstrated that the current dollar amount does not adequately cover the cost of most quantities sufficient for analysis plus reserve samples. This direct final rule is part of FDA's continuing effort to achieve the objectives of the President's "Reinventing Government" initiative, and is intended to reduce the burden of unnecessary regulations on food, drugs, and cosmetics without diminishing the protection of the public health. Elsewhere in this issue of the Federal Register, FDA is publishing a companion proposed rule under FDA's usual procedures for notice and comment to provide a procedural framework to finalize the rule in the event the agency receives any significant adverse comment and withdraws this direct final rule.
Current Knowledge on Cannabinoids in Oral Fluid
Lee, Dayong; Huestis, Marilyn A.
2015-01-01
Oral fluid (OF) is a new biological matrix for clinical and forensic drug testing, offering non-invasive and directly observable sample collection reducing adulteration potential, ease of multiple sample collections, lower biohazard risk during collection, recent exposure identification, and stronger correlation with blood than urine concentrations. Because cannabinoids are usually the most prevalent analytes in illicit drug testing, application of OF drug testing requires sufficient scientific data to support sensitive and specific OF cannabinoid detection. This review presents current knowledge on OF cannabinoids, evaluating pharmacokinetic properties, detection windows, and correlation with other biological matrices and impairment from field applications and controlled drug administration studies. In addition, on-site screening technologies, confirmatory analytical methods, drug stability, and effects of sample collection procedure, adulterants, and passive environmental exposure are reviewed. Delta-9-tetrahydrocannabinol OF concentrations could be > 1000 μg/L shortly after smoking, whereas minor cannabinoids are detected at 10-fold and metabolites at 1000-fold lower concentrations. OF research over the past decade demonstrated that appropriate interpretation of test results requires a comprehensive understanding of distinct elimination profiles and detection windows for different cannabinoids, which are influenced by administration route, dose, and drug use history. Thus, each drug testing program should establish cutoff criteria, collection/analysis procedures, and storage conditions tailored to its purposes. Building a scientific basis for OF testing is on-going, with continuing OF cannabinoids research on passive environmental exposure, drug use history, donor physiological conditions, and oral cavity metabolism needed to better understand mechanisms of cannabinoid OF disposition and expand OF drug testing applicability. PMID:23983217
Fassbender, Amelie; Rahmioglu, Nilufer; Vitonis, Allison F.; Viganò, Paola; Giudice, Linda C.; D’Hooghe, Thomas M.; Hummelshoj, Lone; Adamson, G. David; Becker, Christian M.; Missmer, Stacey A.; Zondervan, Krina T.; Adamson, G.D.; Allaire, C.; Anchan, R.; Becker, C.M.; Bedaiwy, M.A.; Buck Louis, G.M.; Calhaz-Jorge, C.; Chwalisz, K.; D'Hooghe, T.M.; Fassbender, A.; Faustmann, T.; Fazleabas, A.T.; Flores, I.; Forman, A.; Fraser, I.; Giudice, L.C.; Gotte, M.; Gregersen, P.; Guo, S.-W.; Harada, T.; Hartwell, D.; Horne, A.W.; Hull, M.L.; Hummelshoj, L.; Ibrahim, M.G.; Kiesel, L.; Laufer, M.R.; Machens, K.; Mechsner, S.; Missmer, S.A.; Montgomery, G.W.; Nap, A.; Nyegaard, M.; Osteen, K.G.; Petta, C.A.; Rahmioglu, N.; Renner, S.P.; Riedlinger, J.; Roehrich, S.; Rogers, P.A.; Rombauts, L.; Salumets, A.; Saridogan, E.; Seckin, T.; Stratton, P.; Sharpe-Timms, K.L.; Tworoger, S.; Vigano, P.; Vincent, K.; Vitonis, A.F.; Wienhues-Thelen, U.-H.; Yeung, P.P.; Yong, P.; Zondervan, K.T.
2014-01-01
Objective To harmonize standard operating procedures (SOPs) and standardize the recording of associated data for collection, processing, and storage of human tissues relevant to endometriosis. Design An international collaboration involving 34 clinical/academic centers and three industry collaborators from 16 countries on five continents. Setting In 2013, two workshops were conducted followed by global consultation, bringing together 54 leaders in endometriosis research and sample processing from around the world. Patient(s) None. Intervention(s) Consensus SOPs were based on: 1) systematic comparison of SOPs from 24 global centers collecting tissue samples from women with and without endometriosis on a medium or large scale (publication on >100 cases); 2) literature evidence where available, or consultation with laboratory experts otherwise; and 3) several global consultation rounds. Main Outcome Measure(s) Standard recommended and minimum required SOPs for tissue collection, processing, and storage in endometriosis research. Result(s) We developed “recommended standard” and “minimum required” SOPs for the collection, processing, and storage of ectopic and eutopic endometrium, peritoneum, and myometrium, and a biospecimen data collection form necessary for interpretation of sample-derived results. Conclusion(s) The EPHect SOPs allow endometriosis research centers to decrease variability in tissue-based results, facilitating between-center comparisons and collaborations. The procedures are also relevant to research into other gynecologic conditions involving endometrium, myometrium, and peritoneum. The consensus SOPs are based on the best available evidence; areas with limited evidence are identified as requiring further pilot studies. The SOPs will be reviewed based on investigator feedback and through systematic triannual follow-up. Updated versions will be made available at: http://endometriosisfoundation.org/ephect. PMID:25256928
Illustrated field guide for assessing external and internal anomalies in fish
Smith, Stephen B.; Donahue, Anne P.; Lipkin, Robin J.; Blazer, Vicki; Schmitt, Christopher J.; Goede, Ronald W.
2002-01-01
Procedures are described for processing fish for examination of external and internal anomalies and pathologies indicative of exposure to environmental contaminants and other peturbations. For the procedures described here, fish are captured (preferably by electrofishing) and held alive until processing (generally < 1 h). Fish are weighed, measured, and necropsied, and a scale sample is obtained from for age determination. Information is given for the collection and preservation of tissue samples for histopathological analysis. Photographs of most abnormalities are included along with normal conditions for easier identification of external (oral, head, eye, gill, opercula, and fin) and internal (liver, spleen, gonad, and kidney) anomalies. The report also includes recommendations for record keeping, sample labeling, and shipping records, equipment, supplies,and samples. A list of suggested equipment and supplies for field processing is included as are instructions for cleaning equipment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wells, D.
The SRS Interim Sanitary Landfill opened in Mid-1992 and operated until 1998 under Domestic Waste Permit No. 025500-1120. Several contaminants have been detected in the groundwater beneath the unit.The well sampling and analyses were conducted in accordance with Procedure 3Q5, Hydrogeologic Data Collection.
2015-05-01
in consultation with the site management . 4.0 DATA TYPES AND QUALITY CONTROL A sampling plan must account for the collection, handling, and...GUIDANCE DOCUMENT Cost-Effective, Ultra-Sensitive Groundwater Monitoring for Site Remediation and Management : Standard Operating Procedures...Groundwater Monitoring for Site Remediation and Management 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Halden, R.U., Roll, I.B. 5d
EDRN Standard Operating Procedures (SOP) — EDRN Public Portal
The NCI’s Early Detection Research Network is developing a number of standard operating procedures for assays, methods, and protocols for collection and processing of biological samples, and other reference materials to assist investigators to conduct experiments in a consistent, reliable manner. These SOPs are established by the investigators of the Early Detection Research Network to maintain constancy throughout the Network. These SOPs represent neither a consensus, nor are the recommendations of NCI.
Kimball, Judith G; Lynch, Keara M; Stewart, Kelli C; Williams, Nicole E; Thomas, Meghan A; Atwood, Kam D
2007-01-01
This study investigated changes in salivary cortisol, the stress hormone, after administration of a procedure based on the Wilbarger protocol to children diagnosed with sensory defensiveness (SD), a type of sensory modulation dysfunction. Using a single-subject design across participants, we studied 4 boys with SD ages 3 to 5 years. Each participant completed four sessions consisting of the collection of a saliva sample, administration of a procedure based on the Wilbarger protocol, 15 min of quiet neutral activities to allow time for any changes in cortisol level to manifest in the saliva, and the second collection of saliva. Saliva samples were analyzed using enzyme-linked immunosorbent assay (ELISA). Salivary cortisol levels in all participants changed after each of four applications of a procedure based on the Wilbarger protocol. The cortisol levels of 2 children whose levels were relatively higher on pretest decreased at each posttest. The levels of 1 child whose cortisol was higher on pretest three times decreased those three times and increased the one time the pretest cortisol was lower. The levels of 1 child who had the lowest cortisol levels of any of the children increased each time. Therefore, in all participants, cortisol moved in the direction of modulation. In these 4 boys, a procedure based on the Wilbarger protocol modulated cortisol levels toward a middle range. This pilot study indicates that there is an association between sympathetic nervous system response and the Wilbarger protocol-based procedure, as indicated by salivary cortisol levels.
2011-01-01
Background The International Multi-centre ADHD Genetics (IMAGE) project with 11 participating centres from 7 European countries and Israel has collected a large behavioural and genetic database for present and future research. Behavioural data were collected from 1068 probands with the combined type of attention deficit/hyperactivity disorder (ADHD-CT) and 1446 'unselected' siblings. The aim was to analyse the IMAGE sample with respect to demographic features (gender, age, family status, and recruiting centres) and psychopathological characteristics (diagnostic subtype, symptom frequencies, age at symptom detection, and comorbidities). A particular focus was on the effects of the study design and the diagnostic procedure on the homogeneity of the sample in terms of symptom-based behavioural data, and potential consequences for further analyses based on these data. Methods Diagnosis was based on the Parental Account of Childhood Symptoms (PACS) interview and the DSM-IV items of the Conners' teacher questionnaire. Demographics of the full sample and the homogeneity of a subsample (all probands) were analysed by using robust statistical procedures which were adjusted for unequal sample sizes and skewed distributions. These procedures included multi-way analyses based on trimmed means and winsorised variances as well as bootstrapping. Results Age and proband/sibling ratios differed between participating centres. There was no significant difference in the distribution of gender between centres. There was a significant interaction between age and centre for number of inattentive, but not number of hyperactive symptoms. Higher ADHD symptom frequencies were reported by parents than teachers. The diagnostic symptoms differed from each other in their frequencies. The face-to-face interview was more sensitive than the questionnaire. The differentiation between ADHD-CT probands and unaffected siblings was mainly due to differences in hyperactive/impulsive symptoms. Conclusions Despite a symptom-based standardized inclusion procedure according to DSM-IV criteria with defined symptom thresholds, centres may differ markedly in probands' ADHD symptom frequencies. Both the diagnostic procedure and the multi-centre design influence the behavioural characteristics of a sample and, thus, may bias statistical analyses, particularly in genetic or neurobehavioral studies. PMID:21473745
Kaisar, Maria M M; Brienen, Eric A T; Djuardi, Yenny; Sartono, Erliyani; Yazdanbakhsh, Maria; Verweij, Jaco J; Supali, Taniawati; VAN Lieshout, Lisette
2017-06-01
For the majority of intestinal parasites, real-time PCR-based diagnosis outperforms microscopy. However, the data for Trichuris trichiura have been less convincing and most comparative studies have been performed in populations with low prevalence. This study aims to improve detection of T. trichuria DNA in human stool by evaluating four sample preparation methods. Faecal samples (n = 60) were collected at Flores island, Indonesia and examined by microscopy. Aliquots were taken and a bead-beating procedure was used both on directly frozen stool and on material preserved with 96% ethanol. PCR on frozen samples showed 40% to be positive for T. trichiura, compared with 45% positive by microscopy. The percentage positive increased when using ethanol preservation (45·0%), bead-beating (51·7%) and a combination (55·0%) and all three methods showed significantly higher DNA loads. The various procedures had a less pronounced effect on the PCR results of nine other parasite targets tested. Most prevalent were Ascaris lumbricoides (≈60%), Necator americanus (≈60%), Dientamoeba fragilis (≈50%) and Giardia lamblia (≈12%). To validate the practicality of the procedure, bead-beating was applied in a population-based survey testing 910 stool samples. Findings confirmed bead-beating before DNA extraction to be a highly efficient procedure for the detection of T. trichiura DNA in stool.
Preparation of water samples for carbon-14 dating
Feltz, H.R.; Hanshaw, Bruce B.
1963-01-01
For most natural water, a large sample is required to provide the 3 grams of carbon needed for a carbon-14 determination. A field procedure for isolating total dissolved-carbonate species is described. Carbon dioxide gas is evolved by adding sulfuric acid to the water sample; the gas is then collected in a sodium hydroxide trap by recycling in a closed system. The trap is then transported to the dating laboratory where the carbon-14 is counted.
Colomer, Fernando Llavador; Espinós-Morató, Héctor; Iglesias, Enrique Mantilla; Pérez, Tatiana Gómez; Campos-Candel, Andreu; Lozano, Caterina Coll
2012-08-01
A monitoring program based on an indirect method was conducted to assess the approximation of the olfactory impact in several wastewater treatment plants (in the present work, only one is shown). The method uses H2S passive sampling using Palmes-type diffusion tubes impregnated with silver nitrate and fluorometric analysis employing fluorescein mercuric acetate. The analytical procedure was validated in the exposure chamber. Exposure periods ofat least 4 days are recommended. The quantification limit of the procedure is 0.61 ppb for a 5-day sampling, which allows the H2S immission (ground concentration) level to be measured within its low odor threshold, from 0.5 to 300 ppb. Experimental results suggest an exposure time greater than 4 days, while recovery efficiency of the procedure, 93.0+/-1.8%, seems not to depend on the amount of H2S collected by the samplers within their application range. The repeatability, expressed as relative standard deviation, is lower than 7%, which is within the limits normally accepted for this type of sampler. Statistical comparison showed that this procedure and the reference method provide analogous accuracy. The proposed procedure was applied in two experimental campaigns, one intensive and the other extensive, and concentrations within the H2S low odor threshold were quantified at each sampling point. From these results, it can be concluded that the procedure shows good potential for monitoring the olfactory impact around facilities where H2S emissions are dominant.
Colomer, Fernando Llavador; Espinós-Morató, Héctor; Iglesias, Enrique Mantilla; Pérez, Tatiana Gómez; Campos-Candel, Andreu; Coll Lozano, Caterina
2012-08-01
A monitoring program based on an indirect method was conducted to assess the approximation of the olfactory impact in several wastewater treatment plants (in the present work, only one is shown). The method uses H 2 S passive sampling using Palmes-type diffusion tubes impregnated with silver nitrate and fluorometric analysis employing fluorescein mercuric acetate. The analytical procedure was validated in the exposure chamber. Exposure periods of at least 4 days are recommended. The quantification limit of the procedure is 0.61 ppb for a 5-day sampling, which allows the H 2 S immission (ground concentration) level to be measured within its low odor threshold, from 0.5 to 300 ppb. Experimental results suggest an exposure time greater than 4 days, while recovery efficiency of the procedure, 93.0 ± 1.8%, seems not to depend on the amount of H 2 S collected by the samplers within their application range. The repeatability, expressed as relative standard deviation, is lower than 7%, which is within the limits normally accepted for this type of sampler. Statistical comparison showed that this procedure and the reference method provide analogous accuracy. The proposed procedure was applied in two experimental campaigns, one intensive and the other extensive, and concentrations within the H 2 S low odor threshold were quantified at each sampling point. From these results, it can be concluded that the procedure shows good potential for monitoring the olfactory impact around facilities where H 2 S emissions are dominant. [Box: see text].
Ashley, Kevin; Applegate, Gregory T; Marcy, A Dale; Drake, Pamela L; Pierce, Paul A; Carabin, Nathalie; Demange, Martine
2009-02-01
Because toxicities may differ for Cr(VI) compounds of varying solubility, some countries and organizations have promulgated different occupational exposure limits (OELs) for soluble and insoluble hexavalent chromium (Cr(VI)) compounds, and analytical methods are needed to determine these species in workplace air samples. To address this need, international standard methods ASTM D6832 and ISO 16740 have been published that describe sequential extraction techniques for soluble and insoluble Cr(VI) in samples collected from occupational settings. However, no published performance data were previously available for these Cr(VI) sequential extraction procedures. In this work, the sequential extraction methods outlined in the relevant international standards were investigated. The procedures tested involved the use of either deionized water or an ammonium sulfate/ammonium hydroxide buffer solution to target soluble Cr(VI) species. This was followed by extraction in a sodium carbonate/sodium hydroxide buffer solution to dissolve insoluble Cr(VI) compounds. Three-step sequential extraction with (1) water, (2) sulfate buffer and (3) carbonate buffer was also investigated. Sequential extractions were carried out on spiked samples of soluble, sparingly soluble and insoluble Cr(VI) compounds, and analyses were then generally carried out by using the diphenylcarbazide method. Similar experiments were performed on paint pigment samples and on airborne particulate filter samples collected from stainless steel welding. Potential interferences from soluble and insoluble Cr(III) compounds, as well as from Fe(II), were investigated. Interferences from Cr(III) species were generally absent, while the presence of Fe(II) resulted in low Cr(VI) recoveries. Two-step sequential extraction of spiked samples with (first) either water or sulfate buffer, and then carbonate buffer, yielded quantitative recoveries of soluble Cr(VI) and insoluble Cr(VI), respectively. Three-step sequential extraction gave excessively high recoveries of soluble Cr(VI), low recoveries of sparingly soluble Cr(VI), and quantitative recoveries of insoluble Cr(VI). Experiments on paint pigment samples using two-step extraction with water and carbonate buffer yielded varying percentages of relative fractions of soluble and insoluble Cr(VI). Sequential extractions of stainless steel welding fume air filter samples demonstrated the predominance of soluble Cr(VI) compounds in such samples. The performance data obtained in this work support the Cr(VI) sequential extraction procedures described in the international standards.
Sando, Steven K.; Sether, Bradley A.
1993-01-01
Physical-properties were measured and water-quality, plankton, and bottom-material samples were collected at 10 sites in Devils Lake and East Devils Lake during September 1988 through October 1990 to study water-quality variability and water-quality and plankton relations in Devils Lake and East Devils Lake. Physical properties measured include specific conductance, pH, water temperature, dissolved-oxygen concentration, water transparency, and light transmission. Water-quality samples were analyzed for concentrations of major ions, selected nutrients, and selected trace elements. Plankton samples were examined for identification and enumeration of phytoplankton and zooplankton species, and bottom-material samples were analyzed for concentrations of selected nutrients. Data-collection procedures are discussed and the data are presented in tabular form.
Stuntebeck, Todd D.; Komiskey, Matthew J.; Owens, David W.; Hall, David W.
2008-01-01
The University of Wisconsin (UW)-Madison Discovery Farms (Discovery Farms) and UW-Platteville Pioneer Farm (Pioneer Farm) programs were created in 2000 to help Wisconsin farmers meet environmental and economic challenges. As a partner with each program, and in cooperation with the Wisconsin Department of Natural Resources and the Sand County Foundation, the U.S. Geological Survey (USGS) Wisconsin Water Science Center (WWSC) installed, maintained, and operated equipment to collect water-quantity and water-quality data from 25 edge-offield, 6 streamgaging, and 5 subsurface-tile stations at 7 Discovery Farms and Pioneer Farm. The farms are located in the southern half of Wisconsin and represent a variety of landscape settings and crop- and animal-production enterprises common to Wisconsin agriculture. Meteorological stations were established at most farms to measure precipitation, wind speed and direction, air and soil temperature (in profile), relative humidity, solar radiation, and soil moisture (in profile). Data collection began in September 2001 and is continuing through the present (2008). This report describes methods used by USGS WWSC personnel to collect, process, and analyze water-quantity, water-quality, and meteorological data for edge-of-field, streamgaging, subsurface-tile, and meteorological stations at Discovery Farms and Pioneer Farm from September 2001 through October 2007. Information presented includes equipment used; event-monitoring and samplecollection procedures; station maintenance; sample handling and processing procedures; water-quantity, waterquality, and precipitation data analyses; and procedures for determining estimated constituent concentrations for unsampled runoff events.
Wagner, Richard J.; Boulger, Robert W.; Oblinger, Carolyn J.; Smith, Brett A.
2006-01-01
The U.S. Geological Survey uses continuous water-quality monitors to assess the quality of the Nation's surface water. A common monitoring-system configuration for water-quality data collection is the four-parameter monitoring system, which collects temperature, specific conductance, dissolved oxygen, and pH data. Such systems also can be configured to measure other properties, such as turbidity or fluorescence. Data from sensors can be used in conjunction with chemical analyses of samples to estimate chemical loads. The sensors that are used to measure water-quality field parameters require careful field observation, cleaning, and calibration procedures, as well as thorough procedures for the computation and publication of final records. This report provides guidelines for site- and monitor-selection considerations; sensor inspection and calibration methods; field procedures; data evaluation, correction, and computation; and record-review and data-reporting processes, which supersede the guidelines presented previously in U.S. Geological Survey Water-Resources Investigations Report WRIR 00-4252. These procedures have evolved over the past three decades, and the process continues to evolve with newer technologies.
NASA Astrophysics Data System (ADS)
D'Elia, A.; Cibin, G.; Robbins, P. E.; Maggi, V.; Marcelli, A.
2017-11-01
We report on the development of a device designed to improve X-ray Powder Diffraction data acquisition through mapping coupled to a rotational motion of the sample. The device and procedures developed aim at overcoming the experimental issues that accompany the analysis of inhomogeneous samples, such as powders, dust or aerosols deposited on a flat substrate. Introducing the mapping of the substrate on which powders are deposited and at the same time the rotation, we may overcome drawbacks associated to inhomogeneous distributions such as ring-like patterns due to the coffee stain effect generated by the evaporation of a solution. Experimental data have been collected from powders of a NIST standard soil sample (11 μg) and from an airborne dust extracted from deep ice cores in Antarctica (9.6 μg). Both particulate samples have been deposited on polycarbonate membranes from ultra-dilute solutions. Data show that this approach makes possible to collect XRD patterns useful to identify mineral fractions present in these low density samples.
Air-conditioning vs. presence of pathogenic fungi in hospital operating theatre environment.
Gniadek, Agnieszka; Macura, Anna B
2011-01-01
Infections related to modern surgical procedures present a difficult problem for contemporary medicine. Infections acquired during surgery represent a risk factor related to therapeutical interventions. Eradication of microorganisms from hospital operating theatre environment may contribute to reduction of infections as the laminar flow air-conditioning considerably reduces the number of microorganisms in the hospital environment. The objective of the study was to evaluate the occurrence of fungi in air-conditioned operating theatre rooms. The study was carried out in one of the hospitals in Krak6w during December 2009. Indoor air samples and imprints from the walls were collected from five operating theatre rooms. A total of fifty indoor air samples were collected with a MAS-100 device, and twenty five imprints from the walls were collected using a Count Tact method. Fungal growth was observed in 48 air samples; the average numbers of fungi were within the range of 5-100 c.f.u. in one cubic metre of the air. Fungi were detected only in four samples of the wall imprints; the number of fungi was 0.01 c.f.u. per one square centimetre of the surface. The mould genus Aspergillus was most frequently isolated, and the species A. fumigatus and A. versicolor were the dominating ones. To ensure microbiological cleanness of hospital operating theatre, the air-conditioning system should be properly maintained. Domination of the Aspergillus fungi in indoor air as well as increase in the number of moulds in the samples taken in evenings (p < 0.05) may suggest that the room decontamination procedures were neglected.
40 CFR Appendix M to Part 51 - Recommended Test Methods for State Implementation Plans
Code of Federal Regulations, 2014 CFR
2014-07-01
..., and after the run with the cyclone removed. The cyclone is removed before the post-test leak-check to.... 4.1.4.3 Post-Test Leak-Check. A leak-check is required at the conclusion of each sampling run... disturbing the collected sample and use the following procedure to conduct a post-test leak-check. 4.1.4.3.1...
40 CFR Appendix M to Part 51 - Recommended Test Methods for State Implementation Plans
Code of Federal Regulations, 2013 CFR
2013-07-01
..., and after the run with the cyclone removed. The cyclone is removed before the post-test leak-check to.... 4.1.4.3 Post-Test Leak-Check. A leak-check is required at the conclusion of each sampling run... disturbing the collected sample and use the following procedure to conduct a post-test leak-check. 4.1.4.3.1...
40 CFR Appendix M to Part 51 - Recommended Test Methods for State Implementation Plans
Code of Federal Regulations, 2011 CFR
2011-07-01
..., and after the run with the cyclone removed. The cyclone is removed before the post-test leak-check to.... 4.1.4.3 Post-Test Leak-Check. A leak-check is required at the conclusion of each sampling run... disturbing the collected sample and use the following procedure to conduct a post-test leak-check. 4.1.4.3.1...
40 CFR Appendix M to Part 51 - Recommended Test Methods for State Implementation Plans
Code of Federal Regulations, 2012 CFR
2012-07-01
..., and after the run with the cyclone removed. The cyclone is removed before the post-test leak-check to.... 4.1.4.3 Post-Test Leak-Check. A leak-check is required at the conclusion of each sampling run... disturbing the collected sample and use the following procedure to conduct a post-test leak-check. 4.1.4.3.1...
ERIC Educational Resources Information Center
Olatunji, Bunmi O.; Broman-Fulks, Joshua J.; Bergman, Shawn M.; Green, Bradley A.; Zlomke, Kimberly R.
2010-01-01
Worry has been described as a core feature of several disorders, particularly generalized anxiety disorder (GAD). The present study examined the latent structure of worry by applying 3 taxometric procedures (MAXEIG, MAMBAC, and L-Mode) to data collected from 2 large samples. Worry in the first sample (Study 1) of community participants (n = 1,355)…
Pullman, Rebecca E; Roepke, Stephanie E; Duffy, Jeanne F
2012-06-01
To determine whether an accurate circadian phase assessment could be obtained from saliva samples collected by patients in their home. Twenty-four individuals with a complaint of sleep initiation or sleep maintenance difficulty were studied for two evenings. Each participant received instructions for collecting eight hourly saliva samples in dim light at home. On the following evening they spent 9h in a laboratory room with controlled dim (<20 lux) light where hourly saliva samples were collected. Circadian phase of dim light melatonin onset (DLMO) was determined using both an absolute threshold (3 pg ml(-1)) and a relative threshold (two standard deviations above the mean of three baseline values). Neither threshold method worked well for one participant who was a "low-secretor". In four cases the participants' in-lab melatonin levels rose much earlier or were much higher than their at-home levels, and one participant appeared to take the at home samples out of order. Overall, the at-home and in-lab DLMO values were significantly correlated using both methods, and differed on average by 37 (± 19)min using the absolute threshold and by 54 (± 36)min using the relative threshold. The at-home assessment procedure was able to determine an accurate DLMO using an absolute threshold in 62.5% of the participants. Thus, an at-home procedure for assessing circadian phase could be practical for evaluating patients for circadian rhythm sleep disorders. Copyright © 2012 Elsevier B.V. All rights reserved.
The purpose of this SOP is to describe the methods used to collect indoor and outdoor air samples for the determination of selected volatile organic compounds (VOC's) using a pump to draw air through a Carbotrap Sampler. Volatile organic compounds (VOCs) present in the air are p...
Petrovskaya, Natalia B.; Forbes, Emily; Petrovskii, Sergei V.; Walters, Keith F. A.
2018-01-01
Studies addressing many ecological problems require accurate evaluation of the total population size. In this paper, we revisit a sampling procedure used for the evaluation of the abundance of an invertebrate population from assessment data collected on a spatial grid of sampling locations. We first discuss how insufficient information about the spatial population density obtained on a coarse sampling grid may affect the accuracy of an evaluation of total population size. Such information deficit in field data can arise because of inadequate spatial resolution of the population distribution (spatially variable population density) when coarse grids are used, which is especially true when a strongly heterogeneous spatial population density is sampled. We then argue that the average trap count (the quantity routinely used to quantify abundance), if obtained from a sampling grid that is too coarse, is a random variable because of the uncertainty in sampling spatial data. Finally, we show that a probabilistic approach similar to bootstrapping techniques can be an efficient tool to quantify the uncertainty in the evaluation procedure in the presence of a spatial pattern reflecting a patchy distribution of invertebrates within the sampling grid. PMID:29495513
NASA Astrophysics Data System (ADS)
Sari, T. M.; Paidi; Mercuriani, I. S.
2018-03-01
This study was aim to determine Biology procedural knowledge of senior high school in West Lampung based on curriculum at 11th grade in even semester. This research was descriptive research. The population was all students of senior high school in West Lampung. The sampling technique in this research used purposive sampling technique, so the researcher obtained 3 schools using K13 and 3 schools using KTSP. Data collecting technique used instrument test. Data analysis technique used U-Mann Whitney test. The result showed that p=0.028 (p<0.05), so there was significant differences between school using K13 and KTSP. The procedural knowledge of schools which using K13 is higher than school which using KTSP, with the mean score K13=4.35 and KTSP=4.00
Estimating means and variances: The comparative efficiency of composite and grab samples.
Brumelle, S; Nemetz, P; Casey, D
1984-03-01
This paper compares the efficiencies of two sampling techniques for estimating a population mean and variance. One procedure, called grab sampling, consists of collecting and analyzing one sample per period. The second procedure, called composite sampling, collectsn samples per period which are then pooled and analyzed as a single sample. We review the well known fact that composite sampling provides a superior estimate of the mean. However, it is somewhat surprising that composite sampling does not always generate a more efficient estimate of the variance. For populations with platykurtic distributions, grab sampling gives a more efficient estimate of the variance, whereas composite sampling is better for leptokurtic distributions. These conditions on kurtosis can be related to peakedness and skewness. For example, a necessary condition for composite sampling to provide a more efficient estimate of the variance is that the population density function evaluated at the mean (i.e.f(μ)) be greater than[Formula: see text]. If[Formula: see text], then a grab sample is more efficient. In spite of this result, however, composite sampling does provide a smaller estimate of standard error than does grab sampling in the context of estimating population means.
A Comparison of Domain Sampling Procedures for Test Construction
1992-10-01
B AEROSPACE GROUND EQUIPNENT GENERAL MECHANIC AFSC 454X1 306 KNOWLEDGE TEST AFPT 80-423-205 103 AEROSPACE GOUND EQUIPNENT SPECIALTY (AFS 454Xl) JOB... 454X1 ). The information collected will be used for research purposes only and will have no effect on your career. Test results will be available for...exercise proper towing and positioning procedures, operate two-way radios and clean vehicles. 127 AEROSPACE GROUND EQUIPMENT AFSC 454X1 SELF-RATING FORNS
Kap, Marcel; Oomen, Monique; Arshad, Shazia; de Jong, Bas; Riegman, Peter
2014-04-01
About 5000 frozen tissue samples are collected each year by the Erasmus Medical Center tissue bank. Two percent of these samples are randomly selected annually for RNA isolation and RNA Integrity Number (RIN) measurement. A similar quality assessment was conducted during centralization of a 20-year-old tissue collection from the cancer institute, a 15-year-old liver sample archive (-80°C), and a 13-year-old clinical pathology frozen biopsy archive (Liquid Nitrogen). Samples were divided into either high-quality (RIN ≥6.5) or low-quality overall categories, or into four "fit-for-purpose" quality groups: RIN <5: not reliable for demanding downstream analysis; 5 ≤RIN <6: suitable for RT-qPCR; 6 ≤RIN <8: suitable for gene array analysis; and RIN ≥8: suitable for all downstream techniques. In general, low RIN values were correlated with fatty, fibrous, pancreatic, or necrotic tissue. When the percentage of samples with RIN ≥6.5 is higher than 90%, the tissue bank performance is adequate. The annual 2011 quality control assessment showed that 90.3% (n=93) of all samples had acceptable RIN values; 97.4% (n=39) of the cancer institute collection had RIN values above 6.5; and 88.6% (n=123) of samples from the liver sample archive collection had RIN values higher than 6.5. As the clinical pathology biopsy collection contained only 58.8% (n=24) acceptable samples, the procurement protocols used for these samples needed immediate evaluation. When the distribution of RIN values of the different collections were compared, no significant differences were found, despite differences in average storage time and temperature. According to the principle of "fit-for-purpose" distribution, the vast majority of samples are considered good enough for most downstream techniques. In conclusion, an annual tissue bank quality control procedure provides useful information on tissue sample quality and sheds light on where and if improvements need to be made.
Yu, Claro; Zimmerman, Carl; Stone, Roger; Engle, Ronald E; Elkins, William; Nardone, Glenn A; Emerson, Suzanne U; Purcell, Robert H
2007-06-01
Recent reports from Japan implicated wild Sika deer (Cervus nippon) in the zoonotic transmission of hepatitis E to humans. Seroprevalence studies were performed to determine if imported feral populations of Sika deer in Maryland and Virginia posed a similar risk of transmitting hepatitis E virus (HEV). Hunters collected blood on filter paper discs from freshly killed deer. The discs were desiccated and delivered to a collection point. The dried filters were weighed to estimate the amount of blood absorbed and were eluted and collected in one tube via a novel extraction system. The procedure was quantified and validated with negative and positive serum and blood samples obtained from domestic Sika deer before and after immunization with HEV recombinant capsid protein, respectively. None of the 155 tested samples contained antibody to HEV, suggesting that Sika deer in these populations, unlike those in Japan, do not pose a significant zoonotic threat for hepatitis E. However, the new method developed for collecting and eluting the samples should prove useful for field studies of many other pathogens.
Zimmerman, Carl; Stone, Roger; Engle, Ronald E.; Elkins, William; Nardone, Glenn A.; Emerson, Suzanne U.; Purcell, Robert H.
2009-01-01
Recent reports from Japan implicated wild Sika deer (Cervus nippon) in the zoonotic transmission of hepatitis E to humans. Seroprevalence studies were performed to determine if imported feral populations of Sika deer in Maryland and Virginia posed a similar risk of transmitting hepatitis E virus (HEV). Hunters collected blood on filter paper disks from freshly killed deer. The disks were desiccated and delivered to a collection point. The dried filters were weighed to estimate the amount of blood absorbed and were eluted and collected in one tube via a novel extraction system. The procedure was quantified and validated with negative and positive serum and blood samples obtained from domestic Sika deer before and after immunization with HEV recombinant capsid protein, respectively. None of the 155 tested samples contained antibody to HEV, suggesting that Sika deer in these populations, unlike those in Japan, do not pose a significant zoonotic threat for hepatitis E. However, the new method developed for collecting and eluting the samples should prove useful for field studies of many other pathogens. PMID:17336401
Hageman, Philip L.
2007-01-01
New methods for the determination of total mercury in geologic materials and dissolved mercury in aqueous samples have been developed that will replace the methods currently (2006) in use. The new methods eliminate the use of sodium dichromate (Na2Cr2O7 ?2H2O) as an oxidizer and preservative and significantly lower the detection limit for geologic and aqueous samples. The new methods also update instrumentation from the traditional use of cold vapor-atomic absorption spectrometry to cold vapor-atomic fluorescence spectrometry. At the same time, the new digestion procedures for geologic materials use the same size test tubes, and the same aluminum heating block and hot plate as required by the current methods. New procedures for collecting and processing of aqueous samples use the same procedures that are currently (2006) in use except that the samples are now preserved with concentrated hydrochloric acid/bromine monochloride instead of sodium dichromate/nitric acid. Both the 'old' and new methods have the same analyst productivity rates. These similarities should permit easy migration to the new methods. Analysis of geologic and aqueous reference standards using the new methods show that these procedures provide mercury recoveries that are as good as or better than the previously used methods.
Willis, C; Elviss, N; Aird, H; Fenelon, D; McLauchlin, J
2012-08-01
To investigate hygiene practices of caterers at large events in order to: support the production of guidance on catering at such events; to compare hygiene standards at weekends with other times in the week; and to learn lessons in preparation for the London Olympics in 2012. UK-wide study of caterers at large events, including questionnaires on hygiene procedures and microbiological examination of food, water and environmental samples. In total, 1364 samples of food, water, surface swabs and cloths were collected at 139 events, by local authority sampling officers, and transported to laboratories for microbiological analysis. Eight percent of food samples were of an unsatisfactory quality, and a further 2% contained potentially hazardous levels of Bacillus spp. A significantly higher proportion of unsatisfactory food samples were taken from vendors without adequate food safety procedures in place. Fifty-two percent of water samples, 38% of swabs and 71% of cloths were also unsatisfactory. The majority of samples (57%) were collected on Saturdays, Sundays or bank holidays. Environmental swab results were significantly poorer at weekends compared with other days of the week. This study reinforces the fact that food hygiene is a continuing cause for concern in mobile vendors, and indicates a need for an ongoing programme of training and monitoring of caterers in preparation for the London Olympics. Copyright © 2012 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Mittal, R.; Rao, P.; Kaur, P.
2018-01-01
Elemental evaluations in scanty powdered material have been made using energy dispersive X-ray fluorescence (EDXRF) measurements, for which formulations along with specific procedure for sample target preparation have been developed. Fractional amount evaluation involves an itinerary of steps; (i) collection of elemental characteristic X-ray counts in EDXRF spectra recorded with different weights of material, (ii) search for linearity between X-ray counts and material weights, (iii) calculation of elemental fractions from the linear fit, and (iv) again linear fitting of calculated fractions with sample weights and its extrapolation to zero weight. Thus, elemental fractions at zero weight are free from material self absorption effects for incident and emitted photons. The analytical procedure after its verification with known synthetic samples of macro-nutrients, potassium and calcium, was used for wheat plant/ soil samples obtained from a pot experiment.
CTEPP STANDARD OPERATING PROCEDURE FOR CONDUCTING STAFF AND PARTICIPANT TRAINING (SOP-2.27)
This SOP describes the method to train project staff and participants to collect various field samples and questionnaire data for the study. The training plan consists of two separate components: project staff training and participant training. Before project activities begin,...
Treatment Option Overview (Adrenocortical Carcinoma)
... if you have any of these problems. Imaging studies and tests that examine the blood and urine are used ... urine that is collected for three days. This test is done to check if the adrenal gland is ... Blood chemistry study : A procedure in which a blood sample is ...
Stages of Adrenocortical Carcinoma
... if you have any of these problems. Imaging studies and tests that examine the blood and urine are used ... urine that is collected for three days. This test is done to check if the adrenal gland is ... Blood chemistry study : A procedure in which a blood sample is ...
40 CFR 63.5990 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2010 CFR
2010-07-01
... SOURCE CATEGORIES National Emissions Standards for Hazardous Air Pollutants: Rubber Tire Manufacturing...) Performance and equipment specifications for the sample interface, the pollutant concentration or parametric signal analyzer, and the data collection and reduction system; and (3) Performance evaluation procedures...
40 CFR 86.135-90 - Dynamometer procedure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and methanol-fueled Otto-cycle vehicles. The dynamometer run consists of two tests, a “cold” start... analyzed for hydrocarbon, carbon monoxide, carbon dioxide, and oxides of nitrogen. Methanol and formaldehyde samples (exhaust and dilution air) are collected and analyzed for methanol-fueled vehicles (a...
40 CFR 86.135-90 - Dynamometer procedure.
Code of Federal Regulations, 2011 CFR
2011-07-01
... and methanol-fueled Otto-cycle vehicles. The dynamometer run consists of two tests, a “cold” start... analyzed for hydrocarbon, carbon monoxide, carbon dioxide, and oxides of nitrogen. Methanol and formaldehyde samples (exhaust and dilution air) are collected and analyzed for methanol-fueled vehicles (a...
van Ginkel, Joost H; van den Broek, Daan A; van Kuik, Joyce; Linders, Dorothé; de Weger, Roel; Willems, Stefan M; Huibers, Manon M H
2017-10-01
In current molecular cancer diagnostics, using blood samples of cancer patients for the detection of genetic alterations in plasma (cell-free) circulating tumor DNA (ctDNA) is an emerging practice. Since ctDNA levels in blood are low, highly sensitive Droplet Digital PCR (ddPCR) can be used for detecting rare mutational targets. In order to perform ddPCR on blood samples, a standardized procedure for processing and analyzing blood samples is necessary to facilitate implementation into clinical practice. Therefore, we assessed the technical sample workup procedure for ddPCR on blood plasma samples. Blood samples from healthy individuals, as well as lung cancer patients were analyzed. We compared different methods and protocols for sample collection, storage, centrifugation, isolation, and quantification. Cell-free DNA (cfDNA) concentrations of several wild-type targets and BRAF and EGFR-mutant ctDNA concentrations quantified by ddPCR were primary outcome measurements. Highest cfDNA concentrations were measured in blood collected in serum tubes. No significant differences in cfDNA concentrations were detected between various time points of up to 24 h until centrifugation. Highest cfDNA concentrations were detected after DNA isolation with the Quick cfDNA Serum & Plasma Kit, while plasma isolation using the QIAamp Circulating Nucleic Acid Kit yielded the most consistent results. DdPCR results on cfDNA are highly dependent on multiple factors during preanalytical sample workup, which need to be addressed during the development of this diagnostic tool for cancer diagnostics in the future. © 2017 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
The Astromaterials X-Ray Computed Tomography Laboratory at Johnson Space Center
NASA Technical Reports Server (NTRS)
Zeigler, R. A.; Coleff, D. M.; McCubbin, F. M.
2017-01-01
The Astromaterials Acquisition and Curation Office at NASA's Johnson Space Center (hereafter JSC curation) is the past, present, and future home of all of NASA's astromaterials sample collections. JSC curation currently houses all or part of nine different sample collections: (1) Apollo samples (1969), (2) Lunar samples (1972), (3) Antarctic meteorites (1976), (4) Cosmic Dust particles (1981), (5) Microparticle Impact Collection (1985), (6) Genesis solar wind atoms (2004); (7) Stardust comet Wild-2 particles (2006), (8) Stardust interstellar particles (2006), and (9) Hayabusa asteroid Itokawa particles (2010). Each sample collection is housed in a dedicated clean room, or suite of clean rooms, that is tailored to the requirements of that sample collection. Our primary goals are to maintain the long-term integrity of the samples and ensure that the samples are distributed for scientific study in a fair, timely, and responsible manner, thus maximizing the return on each sample. Part of the curation process is planning for the future, and we also perform fundamental research in advanced curation initiatives. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of sample collections, or getting new results from existing sample collections [2]. We are (and have been) planning for future curation, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, and curation of organically- and biologically-sensitive samples. As part of these advanced curation efforts we are augmenting our analytical facilities as well. A micro X-Ray computed tomography (micro-XCT) laboratory dedicated to the study of astromaterials will be coming online this spring within the JSC Curation office, and we plan to add additional facilities that will enable nondestructive (or minimally-destructive) analyses of astromaterials in the near future (micro-XRF, confocal imaging Raman Spectroscopy). These facilities will be available to: (1) develop sample handling and storage techniques for future sample return missions; (2) be utilized by PET for future sample return missions; (3) be used for retroactive PET (Positron Emission Tomography)-style analyses of our existing collections; and (4) for periodic assessments of the existing sample collections. Here we describe the new micro-XCT system, as well as some of the ongoing or anticipated applications of the instrument.
Sampling effort and estimates of species richness based on prepositioned area electrofisher samples
Bowen, Z.H.; Freeman, Mary C.
1998-01-01
Estimates of species richness based on electrofishing data are commonly used to describe the structure of fish communities. One electrofishing method for sampling riverine fishes that has become popular in the last decade is the prepositioned area electrofisher (PAE). We investigated the relationship between sampling effort and fish species richness at seven sites in the Tallapoosa River system, USA based on 1,400 PAE samples collected during 1994 and 1995. First, we estimated species richness at each site using the first-order jackknife and compared observed values for species richness and jackknife estimates of species richness to estimates based on historical collection data. Second, we used a permutation procedure and nonlinear regression to examine rates of species accumulation. Third, we used regression to predict the number of PAE samples required to collect the jackknife estimate of species richness at each site during 1994 and 1995. We found that jackknife estimates of species richness generally were less than or equal to estimates based on historical collection data. The relationship between PAE electrofishing effort and species richness in the Tallapoosa River was described by a positive asymptotic curve as found in other studies using different electrofishing gears in wadable streams. Results from nonlinear regression analyses indicted that rates of species accumulation were variable among sites and between years. Across sites and years, predictions of sampling effort required to collect jackknife estimates of species richness suggested that doubling sampling effort (to 200 PAEs) would typically increase observed species richness by not more than six species. However, sampling effort beyond about 60 PAE samples typically increased observed species richness by < 10%. We recommend using historical collection data in conjunction with a preliminary sample size of at least 70 PAE samples to evaluate estimates of species richness in medium-sized rivers. Seventy PAE samples should provide enough information to describe the relationship between sampling effort and species richness and thus facilitate evaluation of a sampling effort.
Review of Pre-Analytical Errors in Oral Glucose Tolerance Testing in a Tertiary Care Hospital.
Nanda, Rachita; Patel, Suprava; Sahoo, Sibashish; Mohapatra, Eli
2018-03-13
The pre-pre-analytical and pre-analytical phases form a major chunk of the errors in a laboratory. The process has taken into consideration a very common procedure which is the oral glucose tolerance test to identify the pre-pre-analytical errors. Quality indicators provide evidence of quality, support accountability and help in the decision making of laboratory personnel. The aim of this research is to evaluate pre-analytical performance of the oral glucose tolerance test procedure. An observational study that was conducted overa period of three months, in the phlebotomy and accessioning unit of our laboratory using questionnaire that examined the pre-pre-analytical errors through a scoring system. The pre-analytical phase was analyzed for each sample collected as per seven quality indicators. About 25% of the population gave wrong answer with regard to the question that tested the knowledge of patient preparation. The appropriateness of test result QI-1 had the most error. Although QI-5 for sample collection had a low error rate, it is a very important indicator as any wrongly collected sample can alter the test result. Evaluating the pre-analytical and pre-pre-analytical phase is essential and must be conducted routinely on a yearly basis to identify errors and take corrective action and to facilitate their gradual introduction into routine practice.
Palmquist, Emily C.; Ralston, Barbara E.; Sarr, Daniel A.; Johnson, Taylor C.
2018-06-05
Vegetation in the riparian zone (the area immediately adjacent to streams, such as stream banks) along the Colorado River downstream of Glen Canyon Dam, Arizona, supports many ecosystem and societal functions. In both Glen Canyon and Grand Canyon, this ecosystem has changed over time in response to flow alterations, invasive species, and recreational use. Riparian-vegetation cover and composition are likely to continue to change as these pressures persist and new ones emerge. Because this system is a valuable resource that is known to change in response to flow regime and other disturbances, a long-term monitoring protocol has been designed with three primary objectives:Annually measure and summarize the status (composition and cover) of native and non-native vascular-plant species within the riparian zone of the Colorado River between Glen Canyon Dam and Lake Mead.At 5-year intervals, assess change in vegetation composition and cover in the riparian zone, as related to geomorphic setting and dam operations, particularly flow regime.Collect data in a manner that can be used by multiple stakeholders, particularly the basinwide monitoring program overseen by the National Park Service’s Northern Colorado Plateau Network Inventory and Monitoring program.A protocol for the long-term monitoring of riparian vegetation is described in detail and standard operating procedures are included herein for all tasks. Visual estimates of foliar and ground covers are collected in conjunction with environmental measurements to assess correlations of foliar cover with abiotic and flow variables. Sample quadrats are stratified by frequency of inundation, geomorphic feature, and by river segment to account for differences in vegetation type. Photographs of sites are also taken to illustrate qualitative characteristics of the site at the time of sampling. Procedures for field preparation, generating random samples, data collection, data management, collecting and managing unknown species collections, and reporting are also described. Although this protocol is intended to be consistent over the long-term, procedures for minor and major revisions to the protocol are also outlined.
Eder, Anne F; Kennedy, Jean M; Dy, Beth A; Notari, Edward P; Skeate, Robert; Bachowski, Gary; Mair, David C; Webb, Jonathan S; Wagner, Stephen J; Dodd, Roger Y; Benjamin, Richard J
2009-08-01
Septic transfusion reactions to apheresis platelets (PLTs) continue to occur despite preventive measures. This study evaluated the effect of two operational changes designed to reduce bacterial risk: 1) introducing inlet-line sample diversion on two-arm procedures and 2) increasing the sample volume cultured from 4 to 8 mL from all donations. Aerobic culture results and septic transfusion reactions reported between December 1, 2006, and July 31, 2008 (Period 2), were compared to March 1, 2004, to May 31, 2006 (Period 1). During Period 2, a total of 781,936 apheresis PLT collections were cultured, of which 130 donations (1:6015) were confirmed positive and 9 (1:86,882) had negative culture results but were associated with 11 septic reactions. Confirmed-positive cultures from two-arm procedures decreased (27.2 to 14.7 per 105 collections; odds ratio [OR], 0.54; 95% confidence interval [CI], 0.41-0.70) in Period 2, owing to a lower rate of skin flora contamination. Detection of contamination of one-arm collections significantly increased by 54% in Period 2 (13.7 vs. 21.1 per 105 collections; OR, 1.54; 95% CI, 1.05-2.27). Fewer septic transfusion reactions occurred in Period 2, but the difference did not reach significance (1.7 vs. 1.2 per 105 donations; OR, 0.68; 95% CI, 0.30-1.53). Inlet-line diversion decreased bacterial contamination during two-arm collections by more than 46%. Concurrently, doubling the sample volume was associated with a 54% relative increase in culture sensitivity. These interventions act cooperatively to decrease bacterial risk.
Northern Marshall Islands radiological survey: sampling and analysis summary
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robison, W.L.; Conrado, C.L.; Eagle, R.J.
1981-07-23
A radiological survey was conducted in the Northern Marshall Islands to document reamining external gamma exposures from nuclear tests conducted at Enewetak and Bikini Atolls. An additional program was later included to obtain terrestrial and marine samples for radiological dose assessment for current or potential atoll inhabitants. This report is the first of a series summarizing the results from the terrestrial and marine surveys. The sample collection and processing procedures and the general survey methodology are discussed; a summary of the collected samples and radionuclide analyses is presented. Over 5400 samples were collected from the 12 atolls and 2 islandsmore » and prepared for analysis including 3093 soil, 961 vegetation, 153 animal, 965 fish composite samples (average of 30 fish per sample), 101 clam, 50 lagoon water, 15 cistern water, 17 groundwater, and 85 lagoon sediment samples. A complete breakdown by sample type, atoll, and island is given here. The total number of analyses by radionuclide are 8840 for /sup 241/Am, 6569 for /sup 137/Cs, 4535 for /sup 239 +240/Pu, 4431 for /sup 90/Sr, 1146 for /sup 238/Pu, 269 for /sup 241/Pu, and 114 each for /sup 239/Pu and /sup 240/Pu. A complete breakdown by sample category, atoll or island, and radionuclide is also included.« less
GeoLab 2011: New Instruments and Operations Tested at Desert RATS
NASA Technical Reports Server (NTRS)
Evans, Cindy A.; Calaway, M. J.; Bell, M. S.
2012-01-01
GeoLab is a geological laboratory and testbed designed for supporting geoscience activities during NASA's analog demonstrations. Scientists at NASA's Johnson Space Center built GeoLab as part of a technology project to aid the development of science operational concepts for future planetary surface missions [1, 2, 3]. It is integrated into NASA's Habitat Demonstration Unit, a first generation exploration habitat test article. As a prototype workstation, GeoLab provides a high fidelity working space for analog mission crewmembers to perform in-situ characterization of geologic samples and communicate their findings with supporting scientists. GeoLab analog operations can provide valuable data for assessing the operational and scientific considerations of surface-based geologic analyses such as preliminary examination of samples collected by astronaut crews [4, 5]. Our analog tests also feed into sample handling and advanced curation operational concepts and procedures that will, ultimately, help ensure that the most critical samples are collected during future exploration on a planetary surface, and aid decisions about sample prioritization, sample handling and return. Data from GeoLab operations also supports science planning during a mission by providing additional detailed geologic information to supporting scientists, helping them make informed decisions about strategies for subsequent sample collection opportunities.
Long-Term Ecological Monitoring Field Sampling Plan for 2007
DOE Office of Scientific and Technical Information (OSTI.GOV)
T. Haney
2007-07-31
This field sampling plan describes the field investigations planned for the Long-Term Ecological Monitoring Project at the Idaho National Laboratory Site in 2007. This plan and the Quality Assurance Project Plan for Waste Area Groups 1, 2, 3, 4, 5, 6, 7, 10, and Removal Actions constitute the sampling and analysis plan supporting long-term ecological monitoring sampling in 2007. The data collected under this plan will become part of the long-term ecological monitoring data set that is being collected annually. The data will be used t determine the requirements for the subsequent long-term ecological monitoring. This plan guides the 2007more » investigations, including sampling, quality assurance, quality control, analytical procedures, and data management. As such, this plan will help to ensure that the resulting monitoring data will be scientifically valid, defensible, and of known and acceptable quality.« less
NASA Technical Reports Server (NTRS)
Reimold, W. U.; Nyquist, L. E.; Bansal, B. M.; Shih, C.-Y.; Weismann, H.; Wooden, J. L.; Mackinnon, I. D. R.
1985-01-01
The North Ray Crater Target Rock Consortium was formed to study a large number of rake samples collected at Apollo 16 stations 11 and 13 with comparative chemical, mineralogical, and chronological techniques in order to provide a larger data base for the discussion of lunar highland evolution in the vicinity of the Apollo 16 landing region. The present investigation is concerned with Rb-Sr and Sm-Nd isotopic analyses of a number of whole-rock samples of feldspathic microporhyritic (FM) impact melt, a sample type especially abundant among the North Ray crater (station 11) sample collection. Aspects of sample mineralogy and analytical procedures are discussed, taking into account FM impact melt rocks 6715 and 63538, intergranular impact melt rock 67775, subophitic impact melt rock 67747, subophitic impact melt rock 67559, and studies based on the utilization of electron microscopy and mass spectroscopy.
Area estimation using multiyear designs and partial crop identification
NASA Technical Reports Server (NTRS)
Sielken, R. L., Jr.
1984-01-01
Statistical procedures were developed for large area assessments using both satellite and conventional data. Crop acreages, other ground cover indices, and measures of change were the principal characteristics of interest. These characteristics are capable of being estimated from samples collected possibly from several sources at varying times, with different levels of identification. Multiyear analysis techniques were extended to include partially identified samples; the best current year sampling design corresponding to a given sampling history was determined; weights reflecting the precision or confidence in each observation were identified and utilized, and the variation in estimates incorporating partially identified samples were quantified.
Mutagen Sensitivity, Apoptosis, and Polymorphism in DNA Repair as Measures of Prostate Cancer Risk
2005-02-01
blood tubes are immediately refrigerated and delivered on ice within 6 hours to the GCRC core facility at Georgetown University for processing . Case...is CLIA certified. There is a centrally monitored storage facility with -80’C freezers. The established recruitment and optimized sample processing in...controls. We have established the recruitment procedures, sample collection, processing , repository, and data management. This is a substantial effort
Emery, R J
1997-03-01
Institutional radiation safety programs routinely use wipe test sampling and liquid scintillation counting analysis to indicate the presence of removable radioactive contamination. Significant volumes of liquid waste can be generated by such surveillance activities, and the subsequent disposal of these materials can sometimes be difficult and costly. In settings where large numbers of negative results are regularly obtained, the limited grouping of samples for analysis based on expected value statistical techniques is possible. To demonstrate the plausibility of the approach, single wipe samples exposed to varying amounts of contamination were analyzed concurrently with nine non-contaminated samples. Although the sample grouping inevitably leads to increased quenching with liquid scintillation counting systems, the effect did not impact the ability to detect removable contamination in amounts well below recommended action levels. Opportunities to further improve this cost effective semi-quantitative screening procedure are described, including improvements in sample collection procedures, enhancing sample-counting media contact through mixing and extending elution periods, increasing sample counting times, and adjusting institutional action levels.
Horowitz, Arthur J.
2013-01-01
Successful environmental/water quality-monitoring programs usually require a balance between analytical capabilities, the collection and preservation of representative samples, and available financial/personnel resources. Due to current economic conditions, monitoring programs are under increasing pressure to do more with less. Hence, a review of current sampling and analytical methodologies, and some of the underlying assumptions that form the bases for these programs seems appropriate, to see if they are achieving their intended objectives within acceptable error limits and/or measurement uncertainty, in a cost-effective manner. That evaluation appears to indicate that several common sampling/processing/analytical procedures (e.g., dip (point) samples/measurements, nitrogen determinations, total recoverable analytical procedures) are generating biased or nonrepresentative data, and that some of the underlying assumptions relative to current programs, such as calendar-based sampling and stationarity are no longer defensible. The extensive use of statistical models as well as surrogates (e.g., turbidity) also needs to be re-examined because the hydrologic interrelationships that support their use tend to be dynamic rather than static. As a result, a number of monitoring programs may need redesigning, some sampling and analytical procedures may need to be updated, and model/surrogate interrelationships may require recalibration.
Tansel, Berrin; Surita, Sharon C
2016-06-01
Siloxane levels in biogas can jeopardize the warranties of the engines used at the biogas to energy facilities. The chemical structure of siloxanes consists of silicon and oxygen atoms, alternating in position, with hydrocarbon groups attached to the silicon side chain. Siloxanes can be either in cyclic (D) or linear (L) configuration and referred with a letter corresponding to their structure followed by a number corresponding to the number of silicon atoms present. When siloxanes are burned, the hydrocarbon fraction is lost and silicon is converted to silicates. The purpose of this study was to evaluate the adequacy of activated carbon gas samplers for quantitative analysis of siloxanes in biogas samples. Biogas samples were collected from a landfill and an anaerobic digester using multiple carbon sorbent tubes assembled in series. One set of samples was collected for 30min (sampling 6-L gas), and the second set was collected for 60min (sampling 12-L gas). Carbon particles were thermally desorbed and analyzed by Gas Chromatography Mass Spectrometry (GC/MS). The results showed that biogas sampling using a single tube would not adequately capture octamethyltrisiloxane (L3), hexamethylcyclotrisiloxane (D3), octamethylcyclotetrasiloxane (D4), decamethylcyclopentasiloxane (D5) and dodecamethylcyclohexasiloxane (D6). Even with 4 tubes were used in series, D5 was not captured effectively. The single sorbent tube sampling method was adequate only for capturing trimethylsilanol (TMS) and hexamethyldisiloxane (L2). Affinity of siloxanes for activated carbon decreased with increasing molecular weight. Using multiple carbon sorbent tubes in series can be an appropriate method for developing a standard procedure for determining siloxane levels for low molecular weight siloxanes (up to D3). Appropriate quality assurance and quality control procedures should be developed for adequately quantifying the levels of the higher molecular weight siloxanes in biogas with sorbent tubes. Copyright © 2016 Elsevier Ltd. All rights reserved.
Introduction to Field Water-Quality Methods for the Collection of Metals - 2007 Project Summary
Allen, Monica L.
2008-01-01
The U.S. Geological Survey (USGS), Region VI of the U.S. Environmental Protection Agency (USEPA), and the Osage Nation presented three 3-day workshops, in June-August 2007, entitled ?Introduction to Field Water-Quality Methods for the Collection of Metals.? The purpose of the workshops was to provide instruction to tribes within USEPA Region VI on various USGS surface-water measurement methods and water-quality sampling protocols for the collection of surface-water samples for metals analysis. Workshop attendees included members from over 22 tribes and pueblos. USGS instructors came from Oklahoma, New Mexico, and Georgia. Workshops were held in eastern and south-central Oklahoma and New Mexico and covered many topics including presampling preparation, water-quality monitors, and sampling for metals in surface water. Attendees spent one full classroom day learning the field methods used by the USGS Water Resources Discipline and learning about the complexity of obtaining valid water-quality and quality-assurance data. Lectures included (1) a description of metal contamination sources in surface water; (2) introduction on how to select field sites, equipment, and laboratories for sample analysis; (3) collection of sediment in surface water; and (4) utilization of proper protocol and methodology for sampling metals in surface water. Attendees also were provided USGS sampling equipment for use during the field portion of the class so they had actual ?hands-on? experience to take back to their own organizations. The final 2 days of the workshop consisted of field demonstrations of current USGS water-quality sample-collection methods. The hands-on training ensured that attendees were exposed to and experienced proper sampling procedures. Attendees learned integrated-flow techniques during sample collection, field-property documentation, and discharge measurements and calculations. They also used enclosed chambers for sample processing and collected quality-assurance samples to verify their techniques. Benefits of integrated water-quality sample-collection methods are varied. Tribal environmental programs now have the ability to collect data that are comparable across watersheds. The use of consistent sample collection, manipulation, and storage techniques will provide consistent quality data that will enhance the understanding of local water resources. The improved data quality also will help the USEPA better document the condition of the region?s water. Ultimately, these workshops equipped tribes to use uniform sampling methods and to provide consistent quality data that are comparable across the region.
Astromaterials Acquisition and Curation Office (KT) Overview
NASA Technical Reports Server (NTRS)
Allen, Carlton
2014-01-01
The Astromaterials Acquisition and Curation Office has the unique responsibility to curate NASA's extraterrestrial samples - from past and forthcoming missions - into the indefinite future. Currently, curation includes documentation, preservation, physical security, preparation, and distribution of samples from the Moon, asteroids, comets, the solar wind, and the planet Mars. Each of these sample sets has a unique history and comes from a unique environment. The curation laboratories and procedures developed over 40 years have proven both necessary and sufficient to serve the evolving needs of a worldwide research community. A new generation of sample return missions to destinations across the solar system is being planned and proposed. The curators are developing the tools and techniques to meet the challenges of these new samples. Extraterrestrial samples pose unique curation requirements. These samples were formed and exist under conditions strikingly different from those on the Earth's surface. Terrestrial contamination would destroy much of the scientific significance of extraterrestrial materials. To preserve the research value of these precious samples, contamination must be minimized, understood, and documented. In addition, the samples must be preserved - as far as possible - from physical and chemical alteration. The elaborate curation facilities at JSC were designed and constructed, and have been operated for many years, to keep sample contamination and alteration to a minimum. Currently, JSC curates seven collections of extraterrestrial samples: (a)) Lunar rocks and soils collected by the Apollo astronauts, (b) Meteorites collected on dedicated expeditions to Antarctica, (c) Cosmic dust collected by high-altitude NASA aircraft,t (d) Solar wind atoms collected by the Genesis spacecraft, (e) Comet particles collected by the Stardust spacecraft, (f) Interstellar dust particles collected by the Stardust spacecraft, and (g) Asteroid soil particles collected by the Japan Aerospace Exploration Agency (JAXA) Hayabusa spacecraft Each of these sample sets has a unique history and comes from a unique environment. We have developed specialized laboratories and practices over many years to preserve and protect the samples, not only for current research but for studies that may be carried out in the indefinite future.
Pelição, Fabrício Souza; Peres, Mariana Dadalto; Pissinate, Jauber Fornaciari; De Martinis, Bruno Spinosa
2014-01-01
A gas chromatography-mass spectrometric (GC-MS) method was developed and validated for the simultaneous detection and quantification in postmortem whole blood samples of cocaine (COC), amphetamines (AMPs) and cannabis; the main drugs involved in cases of impaired driving in Brazil. The analytes were extracted by solid-phase extraction by means of Bond-Elute Certify cartridges, derivatized with N-methyl-N-(trimethylsilyl)trifluoroacetamide at 80°C for 30 min and analyzed by GC-MS. Linearity ranged from 10 to 500 ng/mL, except for ecgonine methyl ester, for which linearity ranged from 10 to 100 ng/mL. Inter- and intra-day imprecision ranged from 2.8 to 18.4% and from 1.5 to 14.9%, respectively. Accuracy values lay between 86.9 and 104.4%. The limit of quantitation for all drugs was 10 ng/mL and recoveries were >74% for all analytes, except for cannabinoids, which showed poor recovery (∼30%). The developed method was applied to real samples collected from deceased victims due to traffic accidents. These samples were selected according to the results obtained in immunoassay screening on collected urine samples. Five samples were positive for the presence of COC and metabolites, four samples were positive for cannabinoids, six samples were positive for AMPs and two samples were drug negative. Some samples were positive for more than one class of drug. Results obtained from whole blood samples showed good agreement with urine screening. The developed method proved capable of quantifying all three classes of drugs of abuse proposed in this study, through a one-step extraction procedure. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
The role of field auditing in environmental quality assurance management.
Claycomb, D R
2000-01-01
Environmental data quality improvement continues to focus on analytical laboratoryperformance with little, if any, attention given to improving the performance of field consultants responsible for sample collection. Many environmental professionals often assume that the primary opportunity for data error lies within the activities conducted by the laboratory. Experience in the evaluation of environmental data and project-wide quality assurance programs indicates that an often-ignored factor affecting environmental data quality is the manner in which a sample is acquired and handled in the field. If a sample is not properly collected, preserved, stored, and transported in the field, even the best laboratory practices and analytical methods cannot deliver accurate and reliable data (i.e., bad data in equals bad data out). Poor quality environmental data may result in inappropriate decisions regarding site characterization and remedial action. Field auditing is becoming an often-employed technique for examining the performance of the environmental sampling field team and how their performance may affect data quality. The field audits typically focus on: (1) verifying that field consultants adhere to project control documents (e.g., Work Plans and Standard Operating Procedures [SOPs]) during field operations; (2) providing third-party independent assurance that field procedures, quality assurance/ quality control (QA/QC)protocol, and field documentation are sufficient to produce data of satisfactory quality; (3) providing a defense in the event that field procedures are called into question; and (4) identifying ways to reduce sampling costs. Field audits are typically most effective when performed on a surprise basis; that is, the sampling contractor may be aware that a field audit will be conducted during some phase of sampling activities but is not informed of the specific day(s) that the audit will be conducted. The audit also should be conducted early on in the sampling program such that deficiencies noted during the audit can be addressed before the majority of field activities have been completed. A second audit should be performed as a follow-up to confirm that the recommended changes have been implemented. A field auditor is assigned to the project by matching, as closely as possible, the auditor's experience with the type of field activities being conducted. The auditor uses a project-specific field audit checklist developed from key information contained in project control documents. Completion of the extensive audit checklist during the audit focuses the auditor on evaluating each aspect of field activities being performed. Rather than examine field team performance after sampling, a field auditor can do so while the samples are being collected and can apply real-time corrective action as appropriate. As a result of field audits, responsible parties often observe vast improvements in their consultant's field procedures and, consequently, receive more reliable and representative field data at a lower cost. The cost savings and improved data quality that result from properly completed field audits make the field auditing process both cost-effective and functional.
Microflora in soils of desert regions
NASA Technical Reports Server (NTRS)
Cameron, R. E.
1970-01-01
Desert soil samples, collected using aseptic techniques, are low in organic matter and cation exchange capacity. Aerobic and microaerophilic bacteria are most abundant, next are algae and molds. Chemical and physical properties are determined by standard procedures, including the Kjeldahl method and the use of Munsell soil color charts.
FINDING THE BALANCE - QUALITY ASSURANCE REQUIREMENTS VS. RESEARCH NEEDS
Investigators often misapply quality assurance (QA) procedures and may consider QA as a hindrance to developing test plans for sampling and analysis. If used properly, however, QA is the driving force for collecting the right kind and proper amount of data. Researchers must use Q...
FINDING THE BALANCE - QUALITY ASSURANCE REQUIREMENTS VS. RESEARCH NEEDS
Investigators often misapply quality assurance (QA) procedures and may consider QA as a hindrance to developing test plans for
sampling and analysis. If used properly, however, QA is the driving force for collecting the right kind and proper amount of data.
Researchers must...
Treatment Options by Stage (Adrenocortical Carcinoma)
... if you have any of these problems. Imaging studies and tests that examine the blood and urine are used ... urine that is collected for three days. This test is done to check if the adrenal gland is ... Blood chemistry study : A procedure in which a blood sample is ...
Procedure for collecting and packaging grapevine samples
USDA-ARS?s Scientific Manuscript database
Grapevine yellows (GY) is a term that is used to refer to any of several diseases of grapevine (Vitis vinifera) that are caused by phytoplasmas. Around the globe, diverse ‘Candidatus Phytoplasma’ species cause indistinguishable disease symptoms in V. vinifera and are spread by different species of ...
40 CFR 98.186 - Data reporting procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... section (e.g., supplier provided information, analyses of representative samples you collected). (9) If... addition to the information required by § 98.3(c), each annual report must contain the information... the relevant information required by § 98.36 and the information specified in paragraphs (a)(1...
40 CFR 98.186 - Data reporting procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... section (e.g., supplier provided information, analyses of representative samples you collected). (9) If... addition to the information required by § 98.3(c), each annual report must contain the information... the relevant information required by § 98.36 and the information specified in paragraphs (a)(1...
40 CFR 98.186 - Data reporting procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... section (e.g., supplier provided information, analyses of representative samples you collected). (9) If... addition to the information required by § 98.3(c), each annual report must contain the information... the relevant information required by § 98.36 and the information specified in paragraphs (a)(1...
40 CFR 98.186 - Data reporting procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... section (e.g., supplier provided information, analyses of representative samples you collected). (9) If... addition to the information required by § 98.3(c), each annual report must contain the information... the relevant information required by § 98.36 and the information specified in paragraphs (a)(1...
40 CFR 98.186 - Data reporting procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... section (e.g., supplier provided information, analyses of representative samples you collected). (9) If... addition to the information required by § 98.3(c), each annual report must contain the information... the relevant information required by § 98.36 and the information specified in paragraphs (a)(1...
Water Quality & Pollutant Source Monitoring: Field and Laboratory Procedures. Training Manual.
ERIC Educational Resources Information Center
Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.
This training manual presents material on techniques and instrumentation used to develop data in field monitoring programs and related laboratory operations concerned with water quality and pollution monitoring. Topics include: collection and handling of samples; bacteriological, biological, and chemical field and laboratory methods; field…
Preparation of Lead Compounds: An Exercise in Applied Chemistry.
ERIC Educational Resources Information Center
Laing, Michael; And Others
1987-01-01
Describes an exercise developed at the University of Natal (South Africa) in which students visit a plant which manufactures a variety of lead compounds. Outlines the procedures for the laboratory preparation of lead compounds that students prepare with samples they collected at the plant. (TW)
New Noble Gas Studies on Popping Rocks from the Mid-Atlantic Ridge near 14°N
NASA Astrophysics Data System (ADS)
Kurz, M. D.; Curtice, J.; Jones, M.; Péron, S.; Wanless, V. D.; Mittelstaedt, E. L.; Soule, S. A.; Klein, F.; Fornari, D. J.
2017-12-01
New Popping Rocks were recovered in situ on the Mid-Atlantic Ridge (MAR) near 13.77° N, using HOV Alvin on cruise AT33-03 in 2016 on RV Atlantis. We report new helium, neon, argon, and CO2 step-crushing measurements on a subset of the glass samples, with a focus on a new procedure to collect seafloor samples with minimal exposure to air. Glassy seafloor basalts were collected in sealed containers using the Alvin mechanical arm and transported to the surface without atmospheric exposure. On the ship, the seawater was drained, the volcanic glass was transferred to stainless steel ultra-high-vacuum containers (in an oxygen-free glove box), which were then evacuated using a turbo-molecular pump and sealed for transport under vacuum. All processing was carried out under a nitrogen atmosphere. A control sample was collected from each pillow outcrop and processed normally in air. The preliminary step-crushing measurements show that the anaerobically collected samples have systematically higher 20Ne/22Ne, 21Ne/22Ne and 40Ar/36Ar than the control samples. Helium abundances and isotopes are consistent between anaerobically collected samples and control samples. These results suggest that minimizing atmospheric exposure during sample processing can significantly reduce air contamination for heavy noble gases, providing a new option for seafloor sampling. Higher vesicle abundances appear to yield a greater difference in neon and argon isotopes between the anaerobic and control samples, suggesting that atmospheric contamination is related to vesicle abundance, possibly through micro-fractures. The new data show variability in the maximum mantle neon and argon isotopic compositions, and abundance ratios, suggesting that the samples experienced variable outgassing prior to eruption, and may represent different phases of a single eruption, or multiple eruptions.
Kettis-Lindblad, Asa; Ring, Lena; Viberth, Eva; Hansson, Mats G
2007-01-01
To assess the Swedish public's preferences for information and consent procedures when being asked for permission to use previously collected tissue samples for new research studies. Cross-sectional study employing postal questionnaires to a random sample of the Swedish general public (n = 6,000) in October 2002-February 2003. The response rate was 49% (n = 2,928). This paper includes only respondents who reportedly would approve of samples being taken and stored (n = 2,122). When potential tissue sample donors in the general public have to strike a balance between the values at stake, i.e. the autonomy of the donor versus the research value, most (72%) prefer general consent, i.e. where consent is asked for at the outset only. They want the research ethics committee (REC) alone to decide on the use of stored samples, and they would allow storage as long as the sample is useful for research. The minority of respondents who were in favour of specific consent were more likely to be young, well educated, have negative experiences of healthcare and low trust in healthcare authorities. The majority of the Swedish general public prefer general consent, and are thus willing to delegate some decisions to the RECs. However, preferences for information and consent procedures depend on the context, e.g. the risks for the donor and the purpose of the research. If feasible, procedures should be differentiated according to the preferences of individual donors, thus protecting the interests of both the minority and the majority.
NASA GRC and MSFC Space-Plasma Arc Testing Procedures
NASA Technical Reports Server (NTRS)
Ferguson, Dale C.; Vayner, Boris V.; Galofaro, Joel T.; Hillard, G. Barry; Vaughn, Jason; Schneider, Todd
2007-01-01
Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space Flight Center (MSFC) in Huntsville, Alabama, for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing-testing standardization. Discussed herein are neutral gas conditions, plasma densities and uniformity, vacuum chamber sizes, sample sizes and Debye lengths, biasing samples versus self-generated voltages, floating samples versus grounded samples, test electrical conditions, arc detection, preventing sustained discharges during testing, real samples versus idealized samples, validity of LEO tests for GEO samples, extracting arc threshold information from arc rate versus voltage tests, snapover, current collection, and glows at positive sample bias, Kapton pyrolysis, thresholds for trigger arcs, sustained arcs, dielectric breakdown and Paschen discharge, tether arcing and testing in very dense plasmas (i.e. thruster plumes), arc mitigation strategies, charging mitigation strategies, models, and analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.
Kidney cell electrophoresis, continuing task
NASA Technical Reports Server (NTRS)
Todd, P. W.
1985-01-01
Materials and procedures for microgravity electrophoresis of living human embryonic kidney cells were evaluated to provide ground support in the form of analytical cell electrophoresis and flow cytometry. Preflight culture media, electrophoresis buffer, fraction collection media, temperature profiles, and urokinase assay procedures were tested prior to flight. Electrophoretic mobility distributions of aliquots of the cell population to be fractionated in flight were obtained. Cells were prepared in suspension prior to flight in electrophoresis buffer and 10% calf serum. Electrophoretic separation proceeded in electrophoresis buffer without serum in the Continuous Flow Electrophoretic Separator, and fractions were collected into sample bags containing culture medium and concentrated serum. Fractions that yielded enough progeny cells were analyzed for morphology and electrophoretic mobility distributions. It is noted that the lowest mobility fraction studied produced higher mobility progeny while the other fractions produced progeny cells with mobilities related to the fractions from which they were collected.
Abdulla, A M; Hegde, A M
2015-01-01
The aim of the study was to estimate the diurnal variations of salivary cortisol in children with autism and healthy children and it's implication on behavior during non-invasive dental procedures. 50 children with autism and 50 healthy children in the age group between 6 to 12 years of both genders with the need for dental treatment were included in the study. Whole unstimulated saliva was collected from them during early hours of the day and during evenings for 2 consecutive days . The collected saliva was then subjected to electrochemiluminescence assay . Minimum invasive dental procedures like hand scaling, pit and fissure sealants and glass ionomer cement restorations were performed for the participants each time after the saliva sample collection and their behavior during the procedures was rated using Frankl's Behavior Rating Scale. Significant correlation was seen between cortisol levels and behavior in children with autism. As cortisol levels increased in children with autism, behavior worsened and as the cortisol levels decreased they showed positive behaviour. Cortisol acts as a stress marker and studying the diurnal variations of salivary cortisol can help us in attaining better knowledge about the behavior pattern and thereby assist us in modifying the behavior modification procedures and treatment planning in this group of special children.
Kinsey, Willie B.; Johnson, Mark V.; Gronberg, JoAnn M.
2005-01-01
This report contains pesticide, volatile organic compound, major ion, nutrient, tritium, stable isotope, organic carbon, and trace-metal data collected from 149 ground-water wells, and pesticide data collected from 39 surface-water stream sites in the San Joaquin Valley of California. Included with the ground-water data are field measurements of pH, specific conductance, alkalinity, temperature, and dissolved oxygen. This report describes data collection procedures, analytical methods, quality assurance, and quality controls used by the National Water-Quality Assessment Program to ensure data reliability. Data contained in this report were collected during a four year period by the San Joaquin?Tulare Basins Study Unit of the United States Geological Survey's National Water-Quality Assessment Program. Surface-water-quality data collection began in April 1992, with sampling done three times a week at three sites as part of a pilot study conducted to provide background information for the surface-water-study design. Monthly samples were collected at 10 sites for major ions and nutrients from January 1993 to March 1995. Additional samples were collected at four of these sites, from January to December 1993, to study spatial and temporal variability in dissolved pesticide concentrations. Samples for several synoptic studies were collected from 1993 to 1995. Ground-water-quality data collection was restricted to the eastern alluvial fans subarea of the San Joaquin Valley. Data collection began in 1993 with the sampling of 21 wells in vineyard land-use settings. In 1994, 29 wells were sampled in almond land-use settings and 9 in vineyard land-use settings; an additional 11 wells were sampled along a flow path in the eastern Fresno County vineyard land-use area. Among the 79 wells sampled in 1995, 30 wells were in the corn, alfalfa, and vegetable land-use setting, and 1 well was in the vineyard land-use setting; an additional 20 were flow-path wells. Also sampled in 1995 were 28 wells used for a regional assessment of ground-water quality in the eastern San Joaquin Valley.
Sample collection of virulent and non-virulent B. anthracis and Y. pestis for bioforensics analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong-geller, Elizabeth; Valdez, Yolanda E; Shou, Yulin
2009-01-01
Validated sample collection methods are needed for recovery of microbial evidence in the event of accidental or intentional release of biological agents into the environment. To address this need, we evaluated the sample recovery efficiencies of two collection methods -- swabs and wipes -- for both non-virulent and virulent strains of B. anthracis and Y. pestis from four types of non-porous surfaces: two hydrophilic surfaces, stainless steel and glass, and two hydrophobic surfaces, vinyl and plastic. Sample recovery was quantified using Real-time qPCR to assay for intact DNA signatures. We found no consistent difference in collection efficiency between swabs ormore » wipes. Furthermore, collection efficiency was more surface-dependent for virulent strains than non-virulent strains. For the two non-virulent strains, B. anthracis Sterne and Y. pestis A1122, collection efficiency was approximately 100% and 1 %, respectively, from all four surfaces. In contrast, recovery of B. anthracis Ames spores and Y. pestis C092 from vinyl and plastic was generally lower compared to collection from glass or stainless steel, suggesting that surface hydrophobicity may playa role in the strength of pathogen adhesion. The surface-dependent collection efficiencies observed with the virulent strains may arise from strain-specific expression of capsular material or other cell surface receptors that alter cell adhesion to specific surfaces. These findings contribute to validation of standard bioforensics procedures and emphasize the importance of specific strain and surface interactions in pathogen detection.« less
Hong-Geller, E; Valdez, Y E; Shou, Y; Yoshida, T M; Marrone, B L; Dunbar, J M
2010-04-01
We will validate sample collection methods for recovery of microbial evidence in the event of accidental or intentional release of biological agents into the environment. We evaluated the sample recovery efficiencies of two collection methods - swabs and wipes - for both nonvirulent and virulent strains of Bacillus anthracis and Yersinia pestis from four types of nonporous surfaces: two hydrophilic surfaces, stainless steel and glass, and two hydrophobic surfaces, vinyl and plastic. Sample recovery was quantified using real-time qPCR to assay for intact DNA signatures. We found no consistent difference in collection efficiency between swabs or wipes. Furthermore, collection efficiency was more surface-dependent for virulent strains than nonvirulent strains. For the two nonvirulent strains, collection efficiency was similar between all four surfaces, albeit B. anthracis Sterne exhibited higher levels of recovery compared to Y. pestis A1122. In contrast, recovery of B. anthracis Ames spores and Y. pestis CO92 from the hydrophilic glass or stainless steel surfaces was generally more efficient compared to collection from the hydrophobic vinyl and plastic surfaces. Our results suggest that surface hydrophobicity may play a role in the strength of pathogen adhesion. The surface-dependent collection efficiencies observed with the virulent strains may arise from strain-specific expression of capsular material or other cell surface receptors that alter cell adhesion to specific surfaces. These findings contribute to the validation of standard bioforensics procedures and emphasize the importance of specific strain and surface interactions in pathogen detection.
Becker, Christian M.; Laufer, Marc R.; Stratton, Pamela; Hummelshoj, Lone; Missmer, Stacey A.; Zondervan, Krina T.; Adamson, G. David; Adamson, G.D.; Allaire, C.; Anchan, R.; Becker, C.M.; Bedaiwy, M.A.; Buck Louis, G.M.; Calhaz-Jorge, C.; Chwalisz, K.; D'Hooghe, T.M.; Fassbender, A.; Faustmann, T.; Fazleabas, A.T.; Flores, I.; Forman, A.; Fraser, I.; Giudice, L.C.; Gotte, M.; Gregersen, P.; Guo, S.-W.; Harada, T.; Hartwell, D.; Horne, A.W.; Hull, M.L.; Hummelshoj, L.; Ibrahim, M.G.; Kiesel, L.; Laufer, M.R.; Machens, K.; Mechsner, S.; Missmer, S.A.; Montgomery, G.W.; Nap, A.; Nyegaard, M.; Osteen, K.G.; Petta, C.A.; Rahmioglu, N.; Renner, S.P.; Riedlinger, J.; Roehrich, S.; Rogers, P.A.; Rombauts, L.; Salumets, A.; Saridogan, E.; Seckin, T.; Stratton, P.; Sharpe-Timms, K.L.; Tworoger, S.; Vigano, P.; Vincent, K.; Vitonis, A.F.; Wienhues-Thelen, U.-H.; Yeung, P.P.; Yong, P.; Zondervan, K.T.
2014-01-01
Objective To standardize the recording of surgical phenotypic information on endometriosis and related sample collections obtained at laparoscopy, allowing large-scale collaborative research into the condition. Design An international collaboration involving 34 clinical/academic centers and three industry collaborators from 16 countries. Setting Two workshops were conducted in 2013, bringing together 54 clinical, academic, and industry leaders in endometriosis research and management worldwide. Patient(s) None. Intervention(s) A postsurgical scoring sheet containing general and gynecological patient and procedural information, extent of disease, the location and type of endometriotic lesion, and any other findings was developed during several rounds of review. Comments and any systematic surgical data collection tools used in the reviewers' centers were incorporated. Main Outcome Measure(s) The development of a standard recommended (SSF) and minimum required (MSF) form to collect data on the surgical phenotype of endometriosis. Result(s) SSF and MSF include detailed descriptions of lesions, modes of procedures and sample collection, comorbidities, and potential residual disease at the end of surgery, along with previously published instruments such as the revised American Society for Reproductive Medicine and Endometriosis Fertility Index classification tools for comparison and validation. Conclusion(s) This is the first multicenter, international collaboration between academic centers and industry addressing standardization of phenotypic data collection for a specific disease. The Endometriosis Phenome and Biobanking Harmonisation Project SSF and MSF are essential tools to increase our understanding of the pathogenesis of endometriosis by allowing large-scale collaborative research into the condition. PMID:25150390
1979 Reserve Force Studies Surveys: Survey Design, Sample Design and Administrative Procedures,
1981-08-01
three factors: the need for a statistically significant number of usable questionnaires from different groups within the random sampls and from...Because of the multipurpose nature of these surveys and the large number of questions needed to fully address some of the topics covered, we...varies. Collection of data at the unit level is needed to accurately estimate actual reserve compensation and benefits and their possible role in both
Sample Teacher/Student Critical Incident Form.
ERIC Educational Resources Information Center
Bucks County Public Schools, Doylestown, PA.
This form was devised to provide a set of procedures for collecting and utilizing direct observations of specific student behaviors which clearly illustrate the achievement of one of the ten goals of this program. Forms can be used by teachers, students, and parents. (See TM 001 375 for summary of project.) (MS)
9 CFR 113.34 - Detection of hemagglutinating viruses.
Code of Federal Regulations, 2011 CFR
2011-01-01
... REQUIREMENTS Standard Procedures § 113.34 Detection of hemagglutinating viruses. The test for detection of hemagglutinating viruses provided in this section shall be conducted when such a test is prescribed in an... with Newcastle Disease Vaccine, test samples shall be collected from bulk suspensions of each prior to...
9 CFR 113.34 - Detection of hemagglutinating viruses.
Code of Federal Regulations, 2012 CFR
2012-01-01
... REQUIREMENTS Standard Procedures § 113.34 Detection of hemagglutinating viruses. The test for detection of hemagglutinating viruses provided in this section shall be conducted when such a test is prescribed in an... with Newcastle Disease Vaccine, test samples shall be collected from bulk suspensions of each prior to...
9 CFR 113.34 - Detection of hemagglutinating viruses.
Code of Federal Regulations, 2010 CFR
2010-01-01
... REQUIREMENTS Standard Procedures § 113.34 Detection of hemagglutinating viruses. The test for detection of hemagglutinating viruses provided in this section shall be conducted when such a test is prescribed in an... with Newcastle Disease Vaccine, test samples shall be collected from bulk suspensions of each prior to...
Principals' Perceptions of Successful Leadership
ERIC Educational Resources Information Center
Childers, Gary L.
2013-01-01
The purposes of this qualitative multiple case study were to determine the catalysts and pathways that caused principals to move from managers to effective leaders. Data were collected through a series of interviews with 4 principals who were selected through a purposeful sampling procedure. The interviews were audio recorded, transcribed, and…
A Multi-State Study of Off-Farm Employment.
ERIC Educational Resources Information Center
Wozniak, Patricia J.; And Others
1988-01-01
The scope, development, and implementation of a seven-state study on the impact of farm wives' employment on family functioning and economic productivity are described. The procedures used in questionnaire development, sampling, and data collection are reported, along with information on item and unit nonresponse. All the articles in this special…
This method provides a procedure for low level determination of chlorophyll a (chl a) and its magnesium free derivative, pheophytin a (pheo a), in marine and freshwater phytoplankton using fluorescence detection.(1,2) Phaeophorbides present in the sample are determined collective...
This manual describes procedures for collecting samples and field measurements for biotic assemblages and abiotic characteristics of the Great Rivers of the Central Basin of the United States: the Missouri, Upper Mississippi, and Ohio Rivers. In addition to the technical and logi...
Organizational Communication Studies: The LTT and OCD Procedures.
ERIC Educational Resources Information Center
Wiio, Osmo A.
Poor results in organizational communication research may be due to the lack of comparative research, relying instead on small, unrepresentative samples from one or two organizations. Measurement techniques such as the communication audit and the network analysis make possible the comparison of different organizations and the collection of data…
Methods are described for measuring changes in atmospheric O2 concentration with emphasis on gas handling procedures. Cryogenically dried air samples are collected in 5 L glass flasks at ambient pressure and analyzed against reference gases derived from high-pressure aluminum tan...
40 CFR 98.116 - Data reporting requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... information, analyses of representative samples you collected). (7) If you use the missing data procedures in... addition to the information required by § 98.3(c), each annual report must contain the information... you must report under this subpart the relevant information required by § 98.37 for the Tier 4...
40 CFR Appendix 1 to Subpart A of... - Static Sheen Test
Code of Federal Regulations, 2010 CFR
2010-07-01
... drilling fluids, drill cuttings, produced sand, and well treatment, completion and workover fluids. “Free... drill cuttings or produced sand are introduced into ambient seawater in a container having an air-to... specified. 6. Quality Control Procedures None currently specified. 7. Sample Collection and Handling 7...
Molecular epidemiology biomarkers-Sample collection and processing considerations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holland, Nina T.; Pfleger, Laura; Berger, Eileen
2005-08-07
Biomarker studies require processing and storage of numerous biological samples with the goals of obtaining a large amount of information and minimizing future research costs. An efficient study design includes provisions for processing of the original samples, such as cryopreservation, DNA isolation, and preparation of specimens for exposure assessment. Use of standard, two-dimensional and nanobarcodes and customized electronic databases assure efficient management of large sample collections and tracking results of data analyses. Standard operating procedures and quality control plans help to protect sample quality and to assure validity of the biomarker data. Specific state, federal and international regulations are inmore » place regarding research with human samples, governing areas including custody, safety of handling, and transport of human samples. Appropriate informed consent must be obtained from the study subjects prior to sample collection and confidentiality of results maintained. Finally, examples of three biorepositories of different scale (European Cancer Study, National Cancer Institute and School of Public Health Biorepository, University of California, Berkeley) are used to illustrate challenges faced by investigators and the ways to overcome them. New software and biorepository technologies are being developed by many companies that will help to bring biological banking to a new level required by molecular epidemiology of the 21st century.« less
Shih, Chun-Liang; Chong, Kowit-Yu; Hsu, Shih-Che; Chien, Hsin-Jung; Ma, Ching-Ting; Chang, John Wen-Cheng; Yu, Chia-Jung; Chiou, Chiuan-Chian
2016-01-25
Cells release different types of extracellular vesicles (EVs). These EVs contain biomolecules, including proteins and nucleic acids, from their parent cells, which can be useful for diagnostic applications. The aim of this study was to develop a convenient procedure to collect circulating EVs with detectable mRNA or other biomolecules. Magnetic beads coated with annexin A5 (ANX-beads), which bound to phosphatidylserine moieties on the surfaces of most EVs, were tested for their ability to capture induced apoptotic bodies in vitro and other phosphatidylserine-presenting vesicles in body fluids. Our results show that up to 60% of induced apoptotic bodies could be captured by the ANX-beads. The vesicles captured from cultured media or plasma contained amplifiable RNA. Suitable blood samples for EV collection included EDTA-plasma and serum but not heparin-plasma. In addition, EVs in plasma were labile to freeze-and-thaw cycles. In rodents xenografted with human cancer cells, tumor-derived mRNA could be detected in EVs captured from serum samples. Active proteins could be detected in EVs captured from ascites but not from plasma. In conclusion, we have developed a magnetic bead-based procedure for the collection of EVs from body fluids and proved that captured EVs contain biomolecules from their parent cells, and therefore have great potential for disease diagnosis. Copyright © 2015 Elsevier B.V. All rights reserved.
Manual hierarchical clustering of regional geochemical data using a Bayesian finite mixture model
Ellefsen, Karl J.; Smith, David
2016-01-01
Interpretation of regional scale, multivariate geochemical data is aided by a statistical technique called “clustering.” We investigate a particular clustering procedure by applying it to geochemical data collected in the State of Colorado, United States of America. The clustering procedure partitions the field samples for the entire survey area into two clusters. The field samples in each cluster are partitioned again to create two subclusters, and so on. This manual procedure generates a hierarchy of clusters, and the different levels of the hierarchy show geochemical and geological processes occurring at different spatial scales. Although there are many different clustering methods, we use Bayesian finite mixture modeling with two probability distributions, which yields two clusters. The model parameters are estimated with Hamiltonian Monte Carlo sampling of the posterior probability density function, which usually has multiple modes. Each mode has its own set of model parameters; each set is checked to ensure that it is consistent both with the data and with independent geologic knowledge. The set of model parameters that is most consistent with the independent geologic knowledge is selected for detailed interpretation and partitioning of the field samples.
Alworth, Leanne C; Berghaus, Roy D; Kelly, Lisa M; Supakorndej, Prasit; Burkman, Erica J; Savadelis, Molly D; Cooper, Tanya L; Salyards, Gregory W; Harvey, Stephen B; Moorhead, Andrew R
2015-01-01
The NIH guidelines for survival bleeding of mice and rats note that using the retroorbital plexus has a greater potential for complications than do other methods of blood collection and that this procedure should be performed on anesthetized animals. Lateral saphenous vein puncture has a low potential for complications and can be performed without anesthesia. Mongolian gerbils (Meriones unguiculatus) are the preferred rodent model for filarial parasite research. To monitor microfilaria counts in the blood, blood sampling from the orbital plexus has been the standard. Our goal was to refine the blood collection technique. To determine whether blood collection from the lateral saphenous vein was a feasible alternative to retroorbital sampling, we compared microfilaria counts in blood samples collected by both methods from 21 gerbils infected with the filarial parasitic worm Brugia pahangi. Lateral saphenous vein counts were equivalent to retroorbital counts at relatively high counts (greater than 50 microfilariae per 20 µL) but were significantly lower than retroorbital counts when microfilarial concentrations were lower. Our results indicate that although retroorbital collection may be preferable when low concentrations of microfilariae need to be enumerated, the lateral saphenous vein is a suitable alternative site for blood sampling to determine microfilaremia and is a feasible refinement that can benefit the wellbeing of gerbils. PMID:26678366
Sugden, Karen; Danese, Andrea; Shalev, Idan; Williams, Benjamin S; Caspi, Avshalom
2015-01-01
Routine incorporation of blood-based biomarker measurements in population studies has been hampered by challenges in obtaining samples suitable for biomarker assessment outside of laboratory settings. Here, we assessed the suitability of venous blood left unprocessed for 4, 24, or 48 hours post-collection at either room temperature or 4°C for quantification of two biomarkers, Interleukin-6 (IL-6) and C-reactive protein (CRP). Blood samples were collected in both K2EDTA tubes and a dedicated plasma-preservation tube, P100. Dried blood spot (DBS) samples from the same subjects were also collected in order to compare delayed-processing plasma performance against a popular alternative collection method. We found that K2EDTA mean plasma concentrations of both IL-6 and CRP were not significantly different from concentrations in plasma processed immediately; this was observed for tubes stored up to 48 hours pre-processing at either temperature. Concentrations of IL-6 measured in P100 tubes showed significant time-dependent increases when stored at room temperature; otherwise, levels of IL-6 and CRP were similar to those found in samples processed immediately. Levels of CRP in DBS were correlated with plasma CRP levels, even when pre-processed blood was stored for up to 48 hours. These data indicate that plasma is suitable for IL-6 and CRP estimation under data collection conditions that involve processing delays.
USGS Blind Sample Project: monitoring and evaluating laboratory analytical quality
Ludtke, Amy S.; Woodworth, Mark T.
1997-01-01
The U.S. Geological Survey (USGS) collects and disseminates information about the Nation's water resources. Surface- and ground-water samples are collected and sent to USGS laboratories for chemical analyses. The laboratories identify and quantify the constituents in the water samples. Random and systematic errors occur during sample handling, chemical analysis, and data processing. Although all errors cannot be eliminated from measurements, the magnitude of their uncertainty can be estimated and tracked over time. Since 1981, the USGS has operated an independent, external, quality-assurance project called the Blind Sample Project (BSP). The purpose of the BSP is to monitor and evaluate the quality of laboratory analytical results through the use of double-blind quality-control (QC) samples. The information provided by the BSP assists the laboratories in detecting and correcting problems in the analytical procedures. The information also can aid laboratory users in estimating the extent that laboratory errors contribute to the overall errors in their environmental data.
Analytical methods of the U.S. Geological Survey's New York District Water-Analysis Laboratory
Lawrence, Gregory B.; Lincoln, Tricia A.; Horan-Ross, Debra A.; Olson, Mark L.; Waldron, Laura A.
1995-01-01
The New York District of the U.S. Geological Survey (USGS) in Troy, N.Y., operates a water-analysis laboratory for USGS watershed-research projects in the Northeast that require analyses of precipitation and of dilute surface water and soil water for major ions; it also provides analyses of certain chemical constituents in soils and soil gas samples.This report presents the methods for chemical analyses of water samples, soil-water samples, and soil-gas samples collected in wateshed-research projects. The introduction describes the general materials and technicques for each method and explains the USGS quality-assurance program and data-management procedures; it also explains the use of cross reference to the three most commonly used methods manuals for analysis of dilute waters. The body of the report describes the analytical procedures for (1) solution analysis, (2) soil analysis, and (3) soil-gas analysis. The methods are presented in alphabetical order by constituent. The method for each constituent is preceded by (1) reference codes for pertinent sections of the three manuals mentioned above, (2) a list of the method's applications, and (3) a summary of the procedure. The methods section for each constitutent contains the following categories: instrumentation and equipment, sample preservation and storage, reagents and standards, analytical procedures, quality control, maintenance, interferences, safety considerations, and references. Sufficient information is presented for each method to allow the resulting data to be appropriately used in environmental investigations.
Preiksaitis, Carl M; Kuypers, Jane M; Fisher, Cynthia E; Campbell, Angela P; Jerome, Keith R; Huang, Meei-Li; Boeckh, Michael; Limaye, Ajit P
2015-01-01
Methods for the longitudinal study of respiratory virus infections are cumbersome and limit our understanding of the natural history of these infections in solid organ transplant (SOT) recipients. To assess the feasibility and patient acceptability of self-collected foam nasal swabs for detection of respiratory viruses in SOT recipients and to define the virologic and clinical course. We prospectively monitored the course of symptomatic respiratory virus infection in 18 SOT patients (14 lung, 3 liver, and 1 kidney) using patient self-collected swabs. The initial study sample was positive in 15 patients with the following respiratory viruses: rhinovirus (6), metapneumovirus (1), coronavirus (2), respiratory syncytial virus (2), parainfluenza virus (2), and influenza A virus (2). One hundred four weekly self-collected nasal swabs were obtained, with a median of 4 samples per patient (range 1-17). Median duration of viral detection was 21 days (range 4-77 days). Additional new respiratory viruses detected during follow-up of these 15 patients included rhinovirus (3), metapneumovirus (2), coronavirus (1), respiratory syncytial virus (1), parainfluenza virus (1), and adenovirus (1). Specimen collection compliance was good; 16/18 (89%) patients collected all required specimens and 79/86 (92%) follow-up specimens were obtained within the 7 ± 3 day protocol-defined window. All participants agreed or strongly agreed that the procedure was comfortable, simple, and 13/14 (93%) were willing to participate in future studies using this procedure. Self-collected nasal swabs provide a convenient, feasible, and patient-acceptable methodology for longitudinal monitoring of upper respiratory virus infection in SOT recipients. Copyright © 2014 Elsevier B.V. All rights reserved.
Consent process for US-based family reference DNA samples.
Katsanis, Sara H; Snyder, Lindsey; Arnholt, Kelly; Mundorff, Amy Z
2018-01-01
DNA collection from family members of the missing is a tenet for missing persons' and mass fatality investigations. Procedures for consenting family members are disparate, depending on the context supporting the reason for sample collection. While guidelines and best practices have been developed for handling mass fatalities and for identification of the missing, these guidelines do not address standard consent practices for living family members of potential victims. We examined the relevant U.S. laws, international guidelines and best practices, sampled consent forms currently used for DNA collection of family members, and drafted model language for a consent form to communicate the required and recommended information. We modeled the consent form on biobank consenting practices and tested the consent language among students and the general population for constructive feedback and readability. We also asked respondents to consider the options for DNA collection and either hypothetically agree or disagree. The model language presented here highlights information important to relay in consent processes and can serve as a foundation for future consent practices in mass fatalities and missing persons' investigations. Copyright © 2017 Elsevier B.V. All rights reserved.
Dukić, Lora; Simundić, Ana-Maria
2014-01-01
The aim of this survey study was to assess the current practices and policies in use related to the various steps in the blood gas testing process, across hospital laboratories in Croatia. First questionnaire was sent by email to all medical biochemistry laboratories (N = 104) within general, specialized and clinical hospitals and university hospital centres to identify laboratories which perform blood gas analysis. Second questionnaire with detailed questions about sample collection, analysis and quality control procedures, was sent only to 47 laboratories identified by the first survey. Questionnaire was designed as combination of questions and statements with Likert scale. Third questionnaire was sent to all participating laboratories (N=47) for additional clarification for either indeterminate or unclear answers. Blood gas analysis is performed in 47/104 hospital laboratories in Croatia. In 25/41 (0.61) of the laboratories capillary blood gas sampling is the preferred sample type for adult patient population, whereas arterial blood sample is preferentially used in only 5/44 laboratories (0.11). Blood sampling and sample processing for capillary samples is done almost always by laboratory technicians (36/41 and 37/44, respectively), whereas arterial blood sampling is almost always done by the physician (24/29) and only rarely by a nurse (5/28). Sample acceptance criteria and sample analysis are in accordance with international recommendations for majority of laboratories. 43/44 laboratories participate in the national EQA program. POCT analyzers are installed outside of the laboratory in 20/47 (0.43) institutions. Laboratory staff is responsible for education and training of ward personnel, quality control and instrument maintenance in only 12/22, 11/20 and 9/20 institutions, respectively. Practices related to collection and analysis for blood gases in Croatia are not standardised and vary substantially between laboratories. POCT analyzers are not under the direct supervision by laboratory personnel in a large proportion of surveyed institutions. Collective efforts should be made to harmonize and improve policies and procedures related to blood gas testing in Croatian laboratories.
Westenbrink, W
1992-01-01
Police officers can now demand blood samples from suspected impaired drivers in Canada to determine their Blood Alcohol Concentration. The medical laboratory technologist has been given the authority to take blood samples for legal purposes, as well as the authorization to complete certificates used as evidence in court. The proper procedures for the taking of blood samples and the completion of certificates are described in detail. The Criminal Code offences dealing with drinking and driving, the means by which police officers can legally obtain blood samples, the Blood Alcohol Kit, and the provision of providing blood collection evidence in court are discussed to aid the technologists in understanding their role in this process. The Criminal Code definitions of a "qualified medical practitioner", a "qualified technician", and "approved containers" are also described.
Loftin, Keith A.; Meyer, Michael T.; Rubio, Fernando; Kamp, Lisa; Humphries, Edythe; Whereat, Ed
2008-01-01
A collaboration was developed between Abraxis, LLC, the State of Delaware Department of Natural Resources and Environmental Control Division of Water Resources Environmental Laboratory, the University of Delaware, and the United States Geological Survey to investigate the efficacy of the QuikLyse procedure developed by Abraxis, LLC as an alternative cell-lysis technique suitable for use with an existing liquid chromatography/tandem mass spectrometry research method developed at the United States Geological Survey Organic Geochemistry Research Laboratory to analyze cyanotoxins. A comparison of three sequential freeze/thaw cycles versus QuikLyse, a proprietary chemical lysis procedure was conducted on four water samples collected from Silver Lake in Dover, Delaware. Results from the Abraxis Microcystins-DM enzyme-linked immunosorbent assay and liquid chromatography/tandem mass spectrometry were tabulated as a function of the cell lysis technique. Stastical comparison of percent relative standard deviations showed no significant difference (alpha = 0.05) between both cell-lysis techniques when measured by enzyme-linked immunosorbent assay or liquid chromatography/tandem mass spectrometry for three of the four samples.
Determination of lithium in rocks by distillation
Fletcher, M.H.
1949-01-01
A method for the quantitative extraction and recovery of lithium from rocks is based on a high temperature volatilization procedure. The sample is sintered with a calcium carbonate-calcium chloride mixture at 1200?? C. for 30 minutes in a platinum ignition tube, and the volatilization product is collected in a plug of Pyrex glass wool in a connecting Pyrex tube. The distillate, which consists of the alkali chlorides with a maximum of 5 to 20 mg. of calcium oxide and traces of a few other elements, is removed from the apparatus by dissolving in dilute hydrochloric acid and subjected to standard analytiaal procedures. The sinter residues contained less than 0.0005% lithium oxide. Lithium oxide was recovered from synthetic samples with an average error of 1.1%.
Kühn, A; Nieters, A; Köttgen, A; Goek, O N; Michels, K; Nöthlings, U; Jacobs, G; Meisinger, C; Pessler, F; Akmatov, M F; Kühnisch, J; Moebus, S; Glocker, E; Naus, S; Keimling, M; Leitzmann, M; Linseisen, J; Sarioglu, H; von Toerne, C; Hauck, S M; Wallaschofski, H; Wichmann, H E; Illig, Thomas
2014-11-01
The German National Cohort (GNC) is designed to address research questions concerning a wide range of possible causes of major chronic diseases (e.g. cancer, diabetes, infectious, allergic, neurologic and cardiovascular diseases) as well as to identify risk factors and prognostic biomarkers for early diagnosis and prevention of these diseases. The collection of biomaterials in combination with extensive information from questionnaires and medical examinations represents one of the central study components. In two pretest studies of the German National Cohort conducted between 2011 and 2013, a range of biomaterials from a defined number of participants was collected. Ten study centres were involved in pretest 1 and 18 study centres were involved in pretest 2. Standard operation procedures (SOP) were developed and evaluated to minimize pre-analytical artefacts during biosample collection. Within the pretest studies different aspects concerning feasibility of sample collection/preparation [pretest 1 (a)] and quality control of biomarkers and proteome analyses were investigated [pretest 1 (b), (c)]. Additionally, recruitment of study participants for specific projects and examination procedures of all study centres in a defined time period according to common standards as well as transportation and decentralized storage of biological samples were tested (pretest 2). These analyses will serve as the basis for the biomaterial collection in the main study of the GNC starting in 2014. Participants, randomly chosen from the population (n = 1000 subjects recruited at ten study sites in pretest 1) were asked to donate blood, urine, saliva and stool samples. Additionally, nasal and oropharyngeal swabs were collected at the study sites and nasal swabs were collected by the participants at home. SOPs for sample collection, preparation, storage and transportation were developed and adopted for pretest 2. In pretest 2, 18 study sites (n = 599 subjects) collected biomaterials mostly identical to pretest 1. Biomarker analyses to test the quality of the biomaterials were performed. In pretest 1 and 2, it was feasible to collect all biomaterials from nearly all invited participants without major problems. The mean response rate of the subjects was 95 %. As one important result we found for example that after blood draw the cellular fraction should be separated from the plasma and serum fractions during the first hour with no significant variation for up to 6 h at 4 ℃ for all analysed biomarkers. Moreover, quality control of samples using a proteomics approach showed no significant clustering of proteins according to different storage conditions. All developed SOPs were validated for use in the main study after some adaptation and modification. Additionally, electronic and paper documentation sheets were developed and tested to record time stamps, volumes, freezing times, and aliquot numbers of the collected biomaterials. The collection of the biomaterials was feasible without major problems at all participating study sites. However, the processing times were in some cases too long. To avoid pre-analytical artefacts in sample collection, appropriate standardisation among the study sites is necessary. To achieve this, blood and urine collection will have to be adapted to specific conditions of usage of liquid handling robots, which will be available at all participating study centres in the main study of the GNC. Strict compliance with the SOPs, thorough training of the staff and accurate documentation are mandatory to obtain high sample quality for later analyses. The so obtained biomaterials represent a valuable resource for research on infectious and other common complex diseases in the GNC.
Perilymph composition in scala tympani of the cochlea: influence of cerebrospinal fluid.
Hara, A; Salt, A N; Thalmann, R
1989-11-01
A commonly used technique to obtain cochlear perilymph for analysis has been the aspiration of samples through the round window membrane. The present study has investigated the influence of the volume withdrawn on sample composition in the guinea pig. Samples of less than 200 nl in volume taken through the round window showed relatively high glycine content, comparable to the level found in samples taken from scala vestibuli. If larger volumes are withdrawn, lower glycine levels are observed. This is consistent with cerebrospinal fluid (having a low glycine content) being drawn into scala tympani through the cochlear aqueduct and contaminating the sample. The existence of a concentration difference for glycine between scala tympani perilymph and cerebrospinal fluid suggests the physiologic communication across the cochlear aqueduct is relatively small in this species. The observation of considerable exchange between cerebrospinal fluid and perilymph, as reported in some studies, is more likely to be an artifact of the experimental procedures, rather than of physiologic significance. Alternative sampling procedures have been evaluated which allow larger volumes of uncontaminated scala tympani perilymph to be collected.
Lama, Javier R; Karuna, Shelly T; Grant, Shannon P; Swann, Edith M; Ganoza, Carmela; Segura, Patricia; Montano, Silvia M; Lacherre, Martin; De Rosa, Stephen C; Buchbinder, Susan; Sanchez, Jorge; McElrath, M Juliana; Lemos, Maria P
2016-01-01
Rectal and genital sampling in HIV prevention trials permits assessments at the site of HIV entry. Yet the safety and acceptability of circumcision and sigmoidoscopy (and associated abstinence recommendations) are unknown in uncircumcised men who have sex with men (MSM) at high risk of HIV infection. Twenty-nine HIV-seronegative high-risk Peruvian MSM agreed to elective sigmoidoscopy biopsy collections (weeks 2 and 27) and circumcision (week 4) in a 28-week cohort study designed to mimic an HIV vaccine study mucosal collection protocol. We monitored adherence to abstinence recommendations, procedure-related complications, HIV infections, peripheral immune activation, and retention. Twenty-three (79.3%) underwent a first sigmoidoscopy, 21 (72.4%) were circumcised, and 16 (55.2%) completed a second sigmoidoscopy during the study period. All who underwent procedures completed the associated follow-up safety visits. Those completing the procedures reported they were well tolerated, and complication rates were similar to those reported in the literature. Immune activation was detected during the healing period (1 week post-sigmoidoscopy, 6 weeks post-circumcision), including increases in CCR5+CD4+T cells and α4β7+CD4+T cells. Most participants adhered to post-circumcision abstinence recommendations whereas reduced adherence occurred post-sigmoidoscopy. Rectosigmoid mucosal and genital tissue collections were safe in high-risk MSM. Although the clinical implications of the post-procedure increase in peripheral immune activation markers are unknown, they reinforce the need to provide ongoing risk reduction counseling and support for post-procedure abstinence recommendations. Future HIV vaccine studies should also consider the effects of mucosal and tissue collections on peripheral blood endpoints in trial design and analysis. ClinicalTrials.gov NCT02630082.
Spahr, N.E.; Boulger, R.W.
1997-01-01
Quality-control samples provide part of the information needed to estimate the bias and variability that result from sample collection, processing, and analysis. Quality-control samples of surface water collected for the Upper Colorado River National Water-Quality Assessment study unit for water years 1995?96 are presented and analyzed in this report. The types of quality-control samples collected include pre-processing split replicates, concurrent replicates, sequential replicates, post-processing split replicates, and field blanks. Analysis of the pre-processing split replicates, concurrent replicates, sequential replicates, and post-processing split replicates is based on differences between analytical results of the environmental samples and analytical results of the quality-control samples. Results of these comparisons indicate that variability introduced by sample collection, processing, and handling is low and will not affect interpretation of the environmental data. The differences for most water-quality constituents is on the order of plus or minus 1 or 2 lowest rounding units. A lowest rounding unit is equivalent to the magnitude of the least significant figure reported for analytical results. The use of lowest rounding units avoids some of the difficulty in comparing differences between pairs of samples when concentrations span orders of magnitude and provides a measure of the practical significance of the effect of variability. Analysis of field-blank quality-control samples indicates that with the exception of chloride and silica, no systematic contamination of samples is apparent. Chloride contamination probably was the result of incomplete rinsing of the dilute cleaning solution from the outlet ports of the decaport sample splitter. Silica contamination seems to have been introduced by the blank water. Sampling and processing procedures for water year 1997 have been modified as a result of these analyses.
McLachlan, E; Anderson, S; Hawkes, D; Saville, M; Arabena, K
2018-02-01
To examine factors that enhance under-screened and never-screened women's completion of the self-collection alternative pathway of the Renewed National Cervical Screening Program (ncsp) in Victoria, Australia. With the Australian ncsp changing, starting on 1 December 2017, the Medical Services Advisory Committee (msac) recommended implementing human papillomavirus (hpv) testing using a self-collected sample for under-screened and never-screened populations. In response, a multi-agency group implemented an hpv self-collection pilot project to trial self-collection screening pathways for eligible women. Quantitative data were collected on participation rates and compliance rates with follow-up procedures across three primary health care settings. Forty women who self-collected were interviewed in a semi-structured format, and seven agency staff completed in-depth interviews. Qualitative data were used to identify and understand clinical and personal enablers that assisted women to complete self-collection cervical screening pathways successfully. Eighty-five per cent (10 women) of participants who tested positive for hpv successfully received their results and completed follow-up procedures as required. Two remaining participants also received hpv-positive results. However, agencies were unable to engage them in follow-up services and procedures. The overall participation rate in screening (self-collection or Pap test) was 85.7% (84 women), with 79 women self-collecting. Qualitative data indicated that clear explanations on self-collection, development of trusting, empathetic relationships with health professionals, and recognition of participants' past experiences were critical to the successful completion of the self-collection pathway. When asked about possible inhibitors to screening and to following up on results and appointments, women cited poor physical and mental health, as well as financial and other structural barriers. A well-implemented process, led by trusted, knowledgeable, and engaged health care professionals who can provide appropriate support and information, can assist under-screened and never-screened women to complete the hpv self-collection pathway successfully.
Cox, S.E.
2002-01-01
Two low-cost innovative sampling procedures for characterizing trichloroethene (TCE) contamination in ground water were evaluated for use at McChord Air Force Base (AFB) by the U.S. Geological Survey, in cooperation with the U.S. Air Force McChord Air Force Base Installation Restoration Program, in 2001. Previous attempts to characterize the source of ground-water contamination in the heterogeneous glacial outwash aquifer at McChord site SS-34N using soil-gas surveys, direct-push exploration, and more than a dozen ground-water monitoring wells have had limited success. The procedures assessed in this study involved analysis of tree-tissue samples to map underlying ground-water contamination and deploying passive-diffusion samplers to measure TCE concentrations in existing monitoring wells. These procedures have been used successfully at other U.S. Department of Defense sites and have resulted in cost avoidance and accelerated site characterization. Despite the presence of TCE in ground water at site SS-34N, TCE was not detected in any of the 20 trees sampled at the site during either early spring or late summer sampling. The reason the tree tissue procedure was not successful at the McChord AFB site SS-34N may have been due to an inability of tree roots to extract moisture from a water table 30 feet below the land surface, or that concentrations of TCE in ground water were not large enough to be detectable in the tree tissue at the sampling point. Passive-diffusion samplers were placed near the top, middle, and bottom of screened intervals in three monitoring wells and TCE was observed in all samplers. Concentrations of TCE from the passive-diffusion samplers were generally similar to concentrations found in samples collected in the same wells using conventional pumping methods. In contrast to conventional pumping methods, the collection of ground-water samples using the passive-diffusion samples did not generate waste purge water that would require hazardous-waste disposal. In addition, the results from the passive-diffusion samples may show that TCE concentrations are stratified across some screened intervals. The overall results of the limited test of passive-diffusion samplers at site SS-34N were similar to more detailed tests conducted at other contaminated sites across the country and indicate that further evaluation of the use of passive-diffusion samplers at McChord site SS-34N is warranted.
Bern, A.M.; Lowers, H.A.; Meeker, G.P.; Rosati, J.A.
2009-01-01
The collapse of the World Trade Center Towers on September 11, 2001, sent dust and debris across much of Manhattan and in the surrounding areas. Indoor and outdoor dust samples were collected and characterized by U.S. Geological Survey (USGS) scientists using scanning electron microscopy with energy-dispersive spectrometry (SEM/EDS). From this characterization, the U.S. Environmental Protection Agency and USGS developed a particulate screening method to determine the presence of residual World Trade Center dust in the indoor environment using slag wool as a primary "signature". The method describes a procedure that includes splitting, ashing, and sieving of collected dust. From one split, a 10 mg/mL dust/ isopropanol suspension was prepared and 10-30 ??L aliquots of the suspension placed on an SEM substrate. Analyses were performed using SEM/EDS manual point counting for slag wool fibers. Poisson regression was used to identify some of the sources of uncertainty, which are directly related to the small number of fibers present on each sample stub. Preliminary results indicate that the procedure is promising for screening urban background dust for the presence of WTC dust. Consistent sample preparation of reference materials and samples must be performed by each laboratory wishing to use this method to obtain meaningful and accurate results. ?? 2009 American Chemical Society.
Hageman, Philip L.; Briggs, Paul H.; Desborough, George A.; Lamothe, Paul J.; Theodorakos, Peter M.
2000-01-01
This report details chemistry data derived from leaching of mine-waste composite samples using a modification of E.P.A. Method 1312, Synthetic Precipitation Leaching Procedure (SPLP). In 1998, members of the U.S. Geological Survey Mine Waste Characterization Project collected four mine-waste composite samples from mining districts in southwestern New Mexico (CAR and PET) and near Leadville, Colorado (TUC and MII). Resulting leachate pH values for the four composites ranged from 5.45 to 8.84 and ranked in the following order: CAR < TUC < MII < PET. Specific conductivity values ranged from 85 uS/cm to 847 uS/cm in the following order: PET < MII < CAR < TUC. Geochemical data generated from this investigation reveal that leachate from the CAR composite contains the highest concentrations of Pb, Zn, Ni, Mn, Cu, Cd, and Al
A decade of improvements in Mimiviridae and Marseilleviridae isolation from amoeba.
Pagnier, Isabelle; Reteno, Dorine-Gaelle Ikanga; Saadi, Hanene; Boughalmi, Mondher; Gaia, Morgan; Slimani, Meriem; Ngounga, Tatsiana; Bekliz, Meriem; Colson, Philippe; Raoult, Didier; La Scola, Bernard
2013-01-01
Since the isolation of the first giant virus, the Mimivirus, by T.J. Rowbotham in a cooling tower in Bradford, UK, and after its characterisation by our group in 2003, we have continued to develop novel strategies to isolate additional strains. By first focusing on cooling towers using our original time-consuming procedure, we were able to isolate a new lineage of giant virus called Marseillevirus and a new Mimivirus strain called Mamavirus. In the following years, we have accumulated the world's largest unique collection of giant viruses by improving the use of antibiotic combinations to avoid bacterial contamination of amoeba, developing strategies of preliminary screening of samples by molecular methods, and using a high-throughput isolation method developed by our group. Based on the inoculation of nearly 7,000 samples, our collection currently contains 43 strains of Mimiviridae (14 in lineage A, 6 in lineage B, and 23 in lineage C) and 17 strains of Marseilleviridae isolated from various environments, including 3 of human origin. This study details the procedures used to build this collection and paves the way for the high-throughput isolation of new isolates to improve the record of giant virus distribution in the environment and the determination of their pangenome.