Sample records for sample collection processing

  1. Field guide for collecting and processing stream-water samples for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.

    1994-01-01

    The U.S. Geological Survey's National Water-Quality Assessment program includes extensive data- collection efforts to assess the quality of the Nations's streams. These studies require analyses of stream samples for major ions, nutrients, sediments, and organic contaminants. For the information to be comparable among studies in different parts of the Nation, consistent procedures specifically designed to produce uncontaminated samples for trace analysis in the laboratory are critical. This field guide describes the standard procedures for collecting and processing samples for major ions, nutrients, organic contaminants, sediment, and field analyses of conductivity, pH, alkalinity, and dissolved oxygen. Samples are collected and processed using modified and newly designed equipment made of Teflon to avoid contamination, including nonmetallic samplers (D-77 and DH-81) and a Teflon sample splitter. Field solid-phase extraction procedures developed to process samples for organic constituent analyses produce an extracted sample with stabilized compounds for more accurate results. Improvements to standard operational procedures include the use of processing chambers and capsule filtering systems. A modified collecting and processing procedure for organic carbon is designed to avoid contamination from equipment cleaned with methanol. Quality assurance is maintained by strict collecting and processing procedures, replicate sampling, equipment blank samples, and a rigid cleaning procedure using detergent, hydrochloric acid, and methanol.

  2. Evaluation of standard methods for collecting and processing fuel moisture samples

    Treesearch

    Sally M. Haase; José Sánchez; David R. Weise

    2016-01-01

    A variety of techniques for collecting and processing samples to determine moisture content of wildland fuels in support of fire management activities were evaluated. The effects of using a chainsaw or handsaw to collect samples of largediameter wood, containers for storing and transporting collected samples, and quick-response ovens for estimating moisture content...

  3. Pesticide-sampling equipment, sample-collection and processing procedures, and water-quality data at Chicod Creek, North Carolina, 1992

    USGS Publications Warehouse

    Manning, T.K.; Smith, K.E.; Wood, C.D.; Williams, J.B.

    1994-01-01

    Water-quality samples were collected from Chicod Creek in the Coastal Plain Province of North Carolina during the summer of 1992 as part of the U.S. Geological Survey's National Water-Quality Assessment Program. Chicod Creek is in the Albemarle-Pamlico drainage area, one of four study units designated to test equipment and procedures for collecting and processing samples for the solid-phase extraction of selected pesticides, The equipment and procedures were used to isolate 47 pesticides, including organonitrogen, carbamate, organochlorine, organophosphate, and other compounds, targeted to be analyzed by gas chromatography/mass spectrometry. Sample-collection and processing equipment equipment cleaning and set-up procedures, methods pertaining to collecting, splitting, and solid-phase extraction of samples, and water-quality data resulting from the field test are presented in this report Most problems encountered during this intensive sampling exercise were operational difficulties relating to equipment used to process samples.

  4. 21 CFR 111.80 - What representative samples must you collect?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Process Control System § 111.80 What representative samples must you collect? The representative samples... unique lot within each unique shipment); (b) Representative samples of in-process materials for each manufactured batch at points, steps, or stages, in the manufacturing process as specified in the master...

  5. Errors in patient specimen collection: application of statistical process control.

    PubMed

    Dzik, Walter Sunny; Beckman, Neil; Selleng, Kathleen; Heddle, Nancy; Szczepiorkowski, Zbigniew; Wendel, Silvano; Murphy, Michael

    2008-10-01

    Errors in the collection and labeling of blood samples for pretransfusion testing increase the risk of transfusion-associated patient morbidity and mortality. Statistical process control (SPC) is a recognized method to monitor the performance of a critical process. An easy-to-use SPC method was tested to determine its feasibility as a tool for monitoring quality in transfusion medicine. SPC control charts were adapted to a spreadsheet presentation. Data tabulating the frequency of mislabeled and miscollected blood samples from 10 hospitals in five countries from 2004 to 2006 were used to demonstrate the method. Control charts were produced to monitor process stability. The participating hospitals found the SPC spreadsheet very suitable to monitor the performance of the sample labeling and collection and applied SPC charts to suit their specific needs. One hospital monitored subcategories of sample error in detail. A large hospital monitored the number of wrong-blood-in-tube (WBIT) events. Four smaller-sized facilities, each following the same policy for sample collection, combined their data on WBIT samples into a single control chart. One hospital used the control chart to monitor the effect of an educational intervention. A simple SPC method is described that can monitor the process of sample collection and labeling in any hospital. SPC could be applied to other critical steps in the transfusion processes as a tool for biovigilance and could be used to develop regional or national performance standards for pretransfusion sample collection. A link is provided to download the spreadsheet for free.

  6. Data Validation Package - April and July 2015 Groundwater and Surface Water Sampling at the Gunnison, Colorado, Processing Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Linard, Joshua; Campbell, Sam

    This event included annual sampling of groundwater and surface water locations at the Gunnison, Colorado, Processing Site. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites. Samples were collected from 28 monitoring wells, three domestic wells, and six surface locations in April at the processing site as specified in the 2010 Ground Water Compliance Action Plan for the Gunnison, Colorado, Processing Site. Domestic wells 0476 and 0477 were sampled in July because the homes were unoccupied in April, and the wells were not in use. Duplicate samplesmore » were collected from locations 0113, 0248, and 0477. One equipment blank was collected during this sampling event. Water levels were measured at all monitoring wells that were sampled. No issues were identified during the data validation process that requires additional action or follow-up.« less

  7. Occurrence of organic wastewater compounds in effluent-dominated streams in Northeastern Kansas

    USGS Publications Warehouse

    Lee, C.J.; Rasmussen, T.J.

    2006-01-01

    Fifty-nine stream-water samples and 14 municipal wastewater treatment facility (WWTF) discharge samples in Johnson County, northeastern Kansas, were analyzed for 55 compounds collectively described as organic wastewater compounds (OWCs). Stream-water samples were collected upstream, in, and downstream from WWTF discharges in urban and rural areas during base-flow conditions. The effect of secondary treatment processes on OWC occurrence was evaluated by collecting eight samples from WWTF discharges using activated sludge and six from WWTFs samples using trickling filter treatment processes. Samples collected directly from WWTF discharges contained the largest concentrations of most OWCs in this study. Samples from trickling filter discharges had significantly larger concentrations of many OWCs (p-value < 0.05) compared to samples collected from activated sludge discharges. OWC concentrations decreased significantly in samples from WWTF discharges compared to stream-water samples collected from sites greater than 2000??m downstream. Upstream from WWTF discharges, base-flow samples collected in streams draining predominantly urban watersheds had significantly larger concentrations of cumulative OWCs (p-value = 0.03), caffeine (p-value = 0.01), and tris(2-butoxyethyl) phosphate (p-value < 0.01) than those collected downstream from more rural watersheds.

  8. The UK Biobank sample handling and storage protocol for the collection, processing and archiving of human blood and urine.

    PubMed

    Elliott, Paul; Peakman, Tim C

    2008-04-01

    UK Biobank is a large prospective study in the UK to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. Extensive data and biological samples are being collected from 500,000 participants aged between 40 and 69 years. The biological samples that are collected and how they are processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. The aim of the UK Biobank sample handling and storage protocol is to specify methods for the collection and storage of participant samples that give maximum scientific return within the available budget. Processing or storage methods that, as far as can be predicted, will preclude current or future assays have been avoided. The protocol was developed through a review of the literature on sample handling and processing, wide consultation within the academic community and peer review. Protocol development addressed which samples should be collected, how and when they should be processed and how the processed samples should be stored to ensure their long-term integrity. The recommended protocol was extensively tested in a series of validation studies. UK Biobank collects about 45 ml blood and 9 ml of urine with minimal local processing from each participant using the vacutainer system. A variety of preservatives, anti-coagulants and clot accelerators is used appropriate to the expected end use of the samples. Collection of other material (hair, nails, saliva and faeces) was also considered but rejected for the full cohort. Blood and urine samples from participants are transported overnight by commercial courier to a central laboratory where they are processed and aliquots of urine, plasma, serum, white cells and red cells stored in ultra-low temperature archives. Aliquots of whole blood are also stored for potential future production of immortalized cell lines. A standard panel of haematology assays is completed on whole blood from all participants, since such assays need to be conducted on fresh samples (whereas other assays can be done on stored samples). By the end of the recruitment phase, 15 million sample aliquots will be stored in two geographically separate archives: 9.5 million in a -80 degrees C automated archive and 5.5 million in a manual liquid nitrogen archive at -180 degrees C. Because of the size of the study and the numbers of samples obtained from participants, the protocol stipulates a highly automated approach for the processing and storage of samples. Implementation of the processes, technology, systems and facilities has followed best practices used in manufacturing industry to reduce project risk and to build in quality and robustness. The data produced from sample collection, processing and storage are highly complex and are managed by a commercially available LIMS system fully integrated with the entire process. The sample handling and storage protocol adopted by UK Biobank provides quality assured and validated methods that are feasible within the available funding and reflect the size and aims of the project. Experience from recruiting and processing the first 40,000 participants to the study demonstrates that the adopted methods and technologies are fit-for-purpose and robust.

  9. Interim results of quality-control sampling of surface water for the Upper Colorado River National Water-Quality Assessment Study Unit, water years 1995-96

    USGS Publications Warehouse

    Spahr, N.E.; Boulger, R.W.

    1997-01-01

    Quality-control samples provide part of the information needed to estimate the bias and variability that result from sample collection, processing, and analysis. Quality-control samples of surface water collected for the Upper Colorado River National Water-Quality Assessment study unit for water years 1995?96 are presented and analyzed in this report. The types of quality-control samples collected include pre-processing split replicates, concurrent replicates, sequential replicates, post-processing split replicates, and field blanks. Analysis of the pre-processing split replicates, concurrent replicates, sequential replicates, and post-processing split replicates is based on differences between analytical results of the environmental samples and analytical results of the quality-control samples. Results of these comparisons indicate that variability introduced by sample collection, processing, and handling is low and will not affect interpretation of the environmental data. The differences for most water-quality constituents is on the order of plus or minus 1 or 2 lowest rounding units. A lowest rounding unit is equivalent to the magnitude of the least significant figure reported for analytical results. The use of lowest rounding units avoids some of the difficulty in comparing differences between pairs of samples when concentrations span orders of magnitude and provides a measure of the practical significance of the effect of variability. Analysis of field-blank quality-control samples indicates that with the exception of chloride and silica, no systematic contamination of samples is apparent. Chloride contamination probably was the result of incomplete rinsing of the dilute cleaning solution from the outlet ports of the decaport sample splitter. Silica contamination seems to have been introduced by the blank water. Sampling and processing procedures for water year 1997 have been modified as a result of these analyses.

  10. Use of Electronic Hand-held Devices for Collection of Savannah River Site Environmental Data - 13329

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marberry, Hugh; Moore, Winston

    2013-07-01

    Savannah River Nuclear Solutions has begun using Xplore Tablet PC's to collect data in the field for soil samples, groundwater samples, air samples and round sheets at the Savannah River Site (SRS). EPA guidelines for groundwater sampling are incorporated into the application to ensure the sample technician follows the proper protocol. The sample technician is guided through the process for sampling and round sheet data collection by a series of menus and input boxes. Field measurements and well stabilization information are entered into the tablet for uploading into Environmental Restoration Data Management System (ERDMS). The process helps to eliminate inputmore » errors and provides data integrity. A soil sample technician has the ability to collect information about location of sample, field parameter, describe the soil sample, print bottle labels, and print chain of custody for the sample that they have collected. An air sample technician has the ability to provide flow, pressure, hours of operation, print bottle labels and chain of custody for samples they collect. Round sheets are collected using the information provided in the various procedures. The data are collected and uploaded into ERDMS. The equipment used is weather proof and hardened for the field use. Global Positioning System (GPS) capabilities are integrated into the applications to provide the location where samples were collected and to help sample technicians locate wells that are not visited often. (authors)« less

  11. Metabolic profiling of body fluids and multivariate data analysis.

    PubMed

    Trezzi, Jean-Pierre; Jäger, Christian; Galozzi, Sara; Barkovits, Katalin; Marcus, Katrin; Mollenhauer, Brit; Hiller, Karsten

    2017-01-01

    Metabolome analyses of body fluids are challenging due pre-analytical variations, such as pre-processing delay and temperature, and constant dynamical changes of biochemical processes within the samples. Therefore, proper sample handling starting from the time of collection up to the analysis is crucial to obtain high quality samples and reproducible results. A metabolomics analysis is divided into 4 main steps: 1) Sample collection, 2) Metabolite extraction, 3) Data acquisition and 4) Data analysis. Here, we describe a protocol for gas chromatography coupled to mass spectrometry (GC-MS) based metabolic analysis for biological matrices, especially body fluids. This protocol can be applied on blood serum/plasma, saliva and cerebrospinal fluid (CSF) samples of humans and other vertebrates. It covers sample collection, sample pre-processing, metabolite extraction, GC-MS measurement and guidelines for the subsequent data analysis. Advantages of this protocol include: •Robust and reproducible metabolomics results, taking into account pre-analytical variations that may occur during the sampling process•Small sample volume required•Rapid and cost-effective processing of biological samples•Logistic regression based determination of biomarker signatures for in-depth data analysis.

  12. Successful collection of stool samples for microbiome analyses from a large community-based population of elderly men.

    PubMed

    Abrahamson, Melanie; Hooker, Elizabeth; Ajami, Nadim J; Petrosino, Joseph F; Orwoll, Eric S

    2017-09-01

    The relationship of the gastrointestinal microbiome to health and disease is of major research interest, including the effects of the gut microbiota on age related conditions. Here we report on the outcome of a project to collect stool samples on a large number of community dwelling elderly men using the OMNIgene-GUT stool/feces collection kit (OMR-200, DNA Genotek, Ottawa, Canada). Among 1,328 men who were eligible for stool collection, 982 (74%) agreed to participate and 951 submitted samples. The collection process was reported to be acceptable, almost all samples obtained were adequate, the process of sample handling by mail was uniformly successful. The DNA obtained provided excellent results in microbiome analyses, yielding an abundance of species and a diversity of taxa as would be predicted. Our results suggest that population studies of older participants involving remote stool sample collection are feasible. These approaches would allow large scale research projects of the association of the gut microbiota with important clinical outcomes.

  13. Evaluation of process errors in bed load sampling using a Dune Model

    USGS Publications Warehouse

    Gomez, Basil; Troutman, Brent M.

    1997-01-01

    Reliable estimates of the streamwide bed load discharge obtained using sampling devices are dependent upon good at-a-point knowledge across the full width of the channel. Using field data and information derived from a model that describes the geometric features of a dune train in terms of a spatial process observed at a fixed point in time, we show that sampling errors decrease as the number of samples collected increases, and the number of traverses of the channel over which the samples are collected increases. It also is preferable that bed load sampling be conducted at a pace which allows a number of bed forms to pass through the sampling cross section. The situations we analyze and simulate pertain to moderate transport conditions in small rivers. In such circumstances, bed load sampling schemes typically should involve four or five traverses of a river, and the collection of 20–40 samples at a rate of five or six samples per hour. By ensuring that spatial and temporal variability in the transport process is accounted for, such a sampling design reduces both random and systematic errors and hence minimizes the total error involved in the sampling process.

  14. Comparison of Niskin vs. in situ approaches for analysis of gene expression in deep Mediterranean Sea water samples

    NASA Astrophysics Data System (ADS)

    Edgcomb, V. P.; Taylor, C.; Pachiadaki, M. G.; Honjo, S.; Engstrom, I.; Yakimov, M.

    2016-07-01

    Obtaining an accurate picture of microbial processes occurring in situ is essential for our understanding of marine biogeochemical cycles of global importance. Water samples are typically collected at depth and returned to the sea surface for processing and downstream experiments. Metatranscriptome analysis is one powerful approach for investigating metabolic activities of microorganisms in their habitat and which can be informative for determining responses of microbiota to disturbances such as the Deepwater Horizon oil spill. For studies of microbial processes occurring in the deep sea, however, sample handling, pressure, and other changes during sample recovery can subject microorganisms to physiological changes that alter the expression profile of labile messenger RNA. Here we report a comparison of gene expression profiles for whole microbial communities in a bathypelagic water column sample collected in the Eastern Mediterranean Sea using Niskin bottle sample collection and a new water column sampler for studies of marine microbial ecology, the Microbial Sampler - In Situ Incubation Device (MS-SID). For some taxa, gene expression profiles from samples collected and preserved in situ were significantly different from potentially more stressful Niskin sampling and preservation on deck. Some categories of transcribed genes also appear to be affected by sample handling more than others. This suggests that for future studies of marine microbial ecology, particularly targeting deep sea samples, an in situ sample collection and preservation approach should be considered.

  15. Blood Substrate Collection and Handling Procedures under Pseudo-Field Conditions: Evaluation of Suitability for Inflammatory Biomarker Measurement.

    PubMed

    Sugden, Karen; Danese, Andrea; Shalev, Idan; Williams, Benjamin S; Caspi, Avshalom

    2015-01-01

    Routine incorporation of blood-based biomarker measurements in population studies has been hampered by challenges in obtaining samples suitable for biomarker assessment outside of laboratory settings. Here, we assessed the suitability of venous blood left unprocessed for 4, 24, or 48 hours post-collection at either room temperature or 4°C for quantification of two biomarkers, Interleukin-6 (IL-6) and C-reactive protein (CRP). Blood samples were collected in both K2EDTA tubes and a dedicated plasma-preservation tube, P100. Dried blood spot (DBS) samples from the same subjects were also collected in order to compare delayed-processing plasma performance against a popular alternative collection method. We found that K2EDTA mean plasma concentrations of both IL-6 and CRP were not significantly different from concentrations in plasma processed immediately; this was observed for tubes stored up to 48 hours pre-processing at either temperature. Concentrations of IL-6 measured in P100 tubes showed significant time-dependent increases when stored at room temperature; otherwise, levels of IL-6 and CRP were similar to those found in samples processed immediately. Levels of CRP in DBS were correlated with plasma CRP levels, even when pre-processed blood was stored for up to 48 hours. These data indicate that plasma is suitable for IL-6 and CRP estimation under data collection conditions that involve processing delays.

  16. Enumeration of Salmonella and Campylobacter spp. in environmental farm samples and processing plant carcass rinses from commercial broiler chicken flocks.

    PubMed

    Berghaus, Roy D; Thayer, Stephan G; Law, Bibiana F; Mild, Rita M; Hofacre, Charles L; Singer, Randall S

    2013-07-01

    A prospective cohort study was performed to evaluate the prevalences and loads of Salmonella and Campylobacter spp. in farm and processing plant samples collected from 55 commercial broiler chicken flocks. Environmental samples were collected from broiler houses within 48 h before slaughter, and carcass rinses were performed on birds from the same flocks at 4 different stages of processing. Salmonella was detected in farm samples of 50 (90.9%) flocks and in processing samples of 52 (94.5%) flocks. Campylobacter was detected in farm samples of 35 (63.6%) flocks and in processing samples of 48 (87.3%) flocks. There was a significant positive relationship between environmental farm samples and processing plant carcass rinses with respect to both Salmonella and Campylobacter prevalences and loads. Campylobacter loads were significantly higher than Salmonella loads, and the correlations between samples collected from the same flocks were higher for Campylobacter than they were for Salmonella. Boot socks were the most sensitive sample type for detection of Salmonella on the farm, whereas litter samples had the strongest association with Salmonella loads in pre- and postchill carcass rinses. Boot socks, drag swabs, and fecal samples all had similar sensitivities for detecting Campylobacter on the farm, and all were more strongly associated with Campylobacter loads in carcass rinses than were litter samples. Farm samples explained a greater proportion of the variability in carcass rinse prevalences and loads for Campylobacter than they did for Salmonella. Salmonella and Campylobacter prevalences and loads both decreased significantly as birds progressed through the processing plant.

  17. Enumeration of Salmonella and Campylobacter spp. in Environmental Farm Samples and Processing Plant Carcass Rinses from Commercial Broiler Chicken Flocks

    PubMed Central

    Thayer, Stephan G.; Law, Bibiana F.; Mild, Rita M.; Hofacre, Charles L.; Singer, Randall S.

    2013-01-01

    A prospective cohort study was performed to evaluate the prevalences and loads of Salmonella and Campylobacter spp. in farm and processing plant samples collected from 55 commercial broiler chicken flocks. Environmental samples were collected from broiler houses within 48 h before slaughter, and carcass rinses were performed on birds from the same flocks at 4 different stages of processing. Salmonella was detected in farm samples of 50 (90.9%) flocks and in processing samples of 52 (94.5%) flocks. Campylobacter was detected in farm samples of 35 (63.6%) flocks and in processing samples of 48 (87.3%) flocks. There was a significant positive relationship between environmental farm samples and processing plant carcass rinses with respect to both Salmonella and Campylobacter prevalences and loads. Campylobacter loads were significantly higher than Salmonella loads, and the correlations between samples collected from the same flocks were higher for Campylobacter than they were for Salmonella. Boot socks were the most sensitive sample type for detection of Salmonella on the farm, whereas litter samples had the strongest association with Salmonella loads in pre- and postchill carcass rinses. Boot socks, drag swabs, and fecal samples all had similar sensitivities for detecting Campylobacter on the farm, and all were more strongly associated with Campylobacter loads in carcass rinses than were litter samples. Farm samples explained a greater proportion of the variability in carcass rinse prevalences and loads for Campylobacter than they did for Salmonella. Salmonella and Campylobacter prevalences and loads both decreased significantly as birds progressed through the processing plant. PMID:23624481

  18. Rainfall, discharge, and water-quality data during stormwater monitoring, H-1 storm drain, Oahu, Hawaii, July 1, 2009, to June 30, 2010

    USGS Publications Warehouse

    Presley, Todd K.; Jamison, Marcael T.J.

    2010-01-01

    Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. The program is designed to assess the effects of highway runoff and urban runoff collected by the H-1 storm drain on the Manoa-Palolo Drainage Canal. This report summarizes rainfall, discharge, and water-quality data collected between July 1, 2009, and June 30, 2010. As part of this program, rainfall and continuous discharge data were collected at the H-1 storm drain. During the year, sampling strategy and sample processing methods were modified to improve the characterization of the effects of discharge from the storm drain on the Manoa-Palolo Drainage Canal. During July 1, 2009, to February 1, 2010, samples were collected from only the H-1 storm drain. Beginning February 2, 2010, samples were collected simultaneously from the H-1 storm drain and the Manoa-Palolo Drainage Canal at a location about 50 feet upstream of the discharge point of the H-1 storm drain. Three storms were sampled during July 1, 2009, to June 30, 2010. All samples were collected using automatic samplers. For the storm of August 12, 2009, grab samples (for oil and grease, and total petroleum hydrocarbons) and a composite sample were collected. The composite sample was analyzed for total suspended solids, nutrients, and selected dissolved and total (filtered and unfiltered) trace metals (cadmium, chromium, nickel, copper, lead, and zinc). Two storms were sampled in March 2010 at the H-1 storm drain and from the Manoa-Palolo Drainage Canal. Two samples were collected during the storm of March 4, 2010, and six samples were collected during the storm of March 8, 2010. These two storms were sampled using the modified strategy, in which discrete samples from the automatic sampler were processed and analyzed individually, rather than as a composite sample, using the simultaneously collected samples from the H-1 storm drain and from the Manoa-Palolo Drainage Canal. The discrete samples were analyzed for some or all of the following constituents: total suspended solids, nutrients, oil and grease, and selected dissolved (filtered) trace metals (cadmium, chromium, nickel, copper, lead, and zinc). Five quality-assurance/quality-control samples were analyzed during the year. These samples included one laboratory-duplicate, one field-duplicate, and one matrix-spike sample prepared and analyzed with the storm samples. In addition, two inorganic blank-water samples, one sample at the H-1 storm drain and one sample at the Manoa-Palolo Drainage Canal, were collected by running the blank water (water purified of all inorganic constituents) through the sampling and processing systems after cleaning automatic sampler lines to verify that the sampling lines were not contaminated.

  19. Data Validation Package June 2016 Groundwater and Surface Water Sampling at the Old and New Rifle, Colorado, Processing Sites September 2016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bush, Richard; Lemke, Peter

    Sampling Period: June 14–17 and July 7, 2016. Water samples were collected from 36 locations at New Rifle and Old Rifle, Colorado, Disposal/Processing Sites. Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. Duplicate samples were collected from New Rifle locations 0216 and 0855, and Old Rifle location 0655. One equipment blank was collected after decontamination of non-dedicated equipment used to collect one surface water sample. See Attachment 2, Trip Report for additional details. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Managementmore » Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and- analysis-plan-us-department-energy-office-legacy-management-sites). New Rifle Site Samples were collected at the New Rifle site from 16 monitoring wells and 7 surface locations in compliance with the December 2008 Groundwater Compliance Action Plan [GCAP] for the New Rifle, Colorado, Processing Site (LMS/RFN/S01920). Monitoring well 0216 could not be sampled in June because it was surrounded by standing water due to the high river stage from spring runoff, it was later sampled in July. Monitoring well 0635 and surface location 0322 could not be sampled because access through the elk fence along Interstate 70 has not been completed at this time. Old Rifle Site Samples were collected at the Old Rifle site from eight monitoring wells and five surface locations in compliance with the December 2001 Ground Water Compliance Action Plan for the Old Rifle, Colorado, UMTRA Project Site (GJ0-2000-177-TAR).« less

  20. Macroinvertebrate community sample collection methods and data collected from Sand Creek and Medano Creek, Great Sand Dunes National Park and Preserve, Colorado, 2005–07

    USGS Publications Warehouse

    Ford, Morgan A.; Zuellig, Robert E.; Walters, David M.; Bruce, James F.

    2016-08-11

    This report provides a table of site descriptions, sample information, and semiquantitative aquatic macroinvertebrate data from 105 samples collected between 2005 and 2007 from 7 stream sites within the Sand Creek and Medano Creek watersheds in Great Sand Dunes National Park and Preserve, Saguache County, Colorado. Additionally, a short description of sample collection methods and laboratory sample processing procedures is presented. These data were collected in anticipation of assessing the potential effects of fish toxicants on macroinvertebrates.

  1. Collecting, archiving and processing DNA from wildlife samples using FTA® databasing paper

    PubMed Central

    Smith, LM; Burgoyne, LA

    2004-01-01

    Background Methods involving the analysis of nucleic acids have become widespread in the fields of traditional biology and ecology, however the storage and transport of samples collected in the field to the laboratory in such a manner to allow purification of intact nucleic acids can prove problematical. Results FTA® databasing paper is widely used in human forensic analysis for the storage of biological samples and for purification of nucleic acids. The possible uses of FTA® databasing paper in the purification of DNA from samples of wildlife origin were examined, with particular reference to problems expected due to the nature of samples of wildlife origin. The processing of blood and tissue samples, the possibility of excess DNA in blood samples due to nucleated erythrocytes, and the analysis of degraded samples were all examined, as was the question of long term storage of blood samples on FTA® paper. Examples of the end use of the purified DNA are given for all protocols and the rationale behind the processing procedures is also explained to allow the end user to adjust the protocols as required. Conclusions FTA® paper is eminently suitable for collection of, and purification of nucleic acids from, biological samples from a wide range of wildlife species. This technology makes the collection and storage of such samples much simpler. PMID:15072582

  2. Guidelines for the processing and quality assurance of benthic invertebrate samples collected as part of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Cuffney, T.F.; Gurtz, M.E.; Meador, M.R.

    1993-01-01

    Benthic invertebrate samples are collected as part of the U.S. Geological Survey's National Water-Quality Assessment Program. This is a perennial, multidisciplinary program that integrates biological, physical, and chemical indicators of water quality to evaluate status and trends and to develop an understanding of the factors controlling observed water quality. The Program examines water quality in 60 study units (coupled ground- and surface-water systems) that encompass most of the conterminous United States and parts of Alaska and Hawaii. Study-unit teams collect and process qualitative and semi-quantitative invertebrate samples according to standardized procedures. These samples are processed (elutriated and subsampled) in the field to produce as many as four sample components: large-rare, main-body, elutriate, and split. Each sample component is preserved in 10-percent formalin, and two components, large-rare and main-body, are sent to contract laboratories for further processing. The large-rare component is composed of large invertebrates that are removed from the sample matrix during field processing and placed in one or more containers. The main-body sample component consists of the remaining sample materials (sediment, detritus, and invertebrates) and is subsampled in the field to achieve a volume of 750 milliliters or less. The remaining two sample components, elutriate and split, are used for quality-assurance and quality-control purposes. Contract laboratories are used to identify and quantify invertebrates from the large-rare and main-body sample components according to the procedures and guidelines specified within this document. These guidelines allow the use of subsampling techniques to reduce the volume of sample material processed and to facilitate identifications. These processing procedures and techniques may be modified if the modifications provide equal or greater levels of accuracy and precision. The intent of sample processing is to determine the quantity of each taxon present in the semi-quantitative samples or to list the taxa present in qualitative samples. The processing guidelines provide standardized laboratory forms, sample labels, detailed sample processing flow charts, standardized format for electronic data, quality-assurance procedures and checks, sample tracking standards, and target levels for taxonomic determinations. The contract laboratory (1) is responsible for identifications and quantifications, (2) constructs reference collections, (3) provides data in hard copy and electronic forms, (4) follows specified quality-assurance and quality-control procedures, and (5) returns all processed and unprocessed portions of the samples. The U.S. Geological Survey's Quality Management Group maintains a Biological Quality-Assurance Unit, located at the National Water-Quality Laboratory, Arvada, Colorado, to oversee the use of contract laboratories and ensure the quality of data obtained from these laboratories according to the guidelines established in this document. This unit establishes contract specifications, reviews contractor performance (timeliness, accuracy, and consistency), enters data into the National Water Information System-II data base, maintains in-house reference collections, deposits voucher specimens in outside museums, and interacts with taxonomic experts within and outside the U.S. Geological Survey. This unit also modifies the existing sample processing and quality-assurance guidelines, establishes criteria and testing procedures for qualifying potential contract laboratories, identifies qualified taxonomic experts, and establishes voucher collections.

  3. Guidelines for collecting and processing samples of stream bed sediment for analysis of trace elements and organic contaminants for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.; Capel, Paul D.

    1994-01-01

    A major component of the U.S. Geological Survey's National Water-Quality Assessment program is to assess the occurrence and distribution of trace elements and organic contaminants in streams. The first phase of the strategy for the assessment is to analyze samples of bed sediments from depositional zones. Fine-grained particles deposited in these zones are natural accumulators of trace elements and hydrophobic organic compounds. For the information to be comparable among studies in many different parts of the Nation, strategies for selecting stream sites and depositional zones are critical. Fine-grained surficial sediments are obtained from several depositional zones within a stream reach and composited to yield a sample representing average conditions. Sample collection and processing must be done consistently and by procedures specifically designed to separate the fine material into fractions that yield uncontaminated samples for trace-level analytes in the laboratory. Special coring samplers and other instruments made of Teflon are used for collection. Samples are processed through a 2.0-millimeter stainless-steel mesh sieve for organic contaminate analysis and a 63-micrometer nylon-cloth sieve for trace-element analysis. Quality assurance is maintained by strict collection and processing procedures, duplicate samplings, and a rigid cleaning procedure.

  4. Prevalence, types, and geographical distribution of Listeria monocytogenes from a survey of retail Queso Fresco and associated cheese processing plants and dairy farms in Sonora, Mexico.

    PubMed

    Moreno-Enriquez, R I; Garcia-Galaz, A; Acedo-Felix, E; Gonzalez-Rios, I H; Call, J E; Luchansky, J B; Diaz-Cinco, M E

    2007-11-01

    In the first part of this study, samples were collected from farms, cheese processing plants (CPPs), and retail markets located in various geographical areas of Sonora, Mexico, over a 12-month period during the summer of 2004 and winter of 2005. Four (all Queso Fresco [QF] from retail markets) of 349 total samples tested positive for Listeria monocytogenes (Lm). Of these four positive samples, three were collected in the northern region and one in the southern region of Sonora. Additionally, two were collected during the winter months, and two were collected during the summer months. For the second part of the study, a total of 39 samples from a farm, a CPP, and retail markets were collected and processed according to a combination of the Norma Oficial Mexicana NOM-143-SSA1-1995.10 method (NOM) and the U.S. Food and Drug Administration (FDA) Bacteriological Analytical Manual method, and 27 samples from these same locations were collected and processed according to the U.S. Department of Agriculture Food Safety and Inspection Service method (USDA-FSIS). The NOM-FDA method recovered the pathogen from 6 (15%) of 39 samples (one cheese and five product contact surfaces), while the USDA-FSIS method recovered the pathogen from 5 (18.5%) of 27 samples (all product contact surfaces). In addition, the 40 isolates recovered from the 15 total samples that tested positive for Lm grouped into five distinct pulsotypes that were ca. 60% related, as determined by pulsed-field gel electrophoresis analysis. The results of this study confirmed a 3.4% prevalence of Lm in QF collected from retail markets located in Sonora and no appreciable difference in the effectiveness of either the NOM-FDA or USDA-FSIS method to recover the pathogen from cheese or environmental samples.

  5. Campylobacter in chicken carcasses and slaughterhouses in Malaysia.

    PubMed

    Rejab, Saira Banu Mohamed; Zessin, Karl-Hans; Fries, Reinhard; Patchanee, Prapas

    2012-01-01

    This study was conducted to determine the Campylobacter contamination rate of chicken carcasses and the processing lines of modern processing plants in Malaysia. Three hundred sixty samples were collected from 24 flocks of broiler chickens at 12 modern poultry processing plants in 6 states of Malaysia. Fresh fecal droppings were collected from crates in the arrival area. Neck skin samples were taken from processed chicken carcasses at 3 different processing stages: before inside-outside washing, after inside-outside washing and post chilling. Swab samples from the scalding tank, chilling tank and conveyer belt before chilling were also collected to determine contamination with Campylobacter in the slaughter house environment prior to slaughter. Isolation for Campylobacter was performed following ISO 10272-1:2006(E). The overall of contamination rate with Campylobacter at the 12 plants was 61.0% (220/360). Eighty point six percent of the samples from before the inside-outside wishing step were contaminated with Campylobacter, as were 62.5% of the samples after the inside washing and 38.9% after the post-chilling step. This study shows extensive contamination of chicken carcasses and slaughtering houses in Malaysia with Campylobacter.

  6. Sampling procedure for lake or stream surface water chemistry

    Treesearch

    Robert Musselman

    2012-01-01

    Surface waters collected in the field for chemical analyses are easily contaminated. This research note presents a step-by-step detailed description of how to avoid sample contamination when field collecting, processing, and transporting surface water samples for laboratory analysis.

  7. Vaginal Prostate Specific Antigen (PSA) Is a Useful Biomarker of Semen Exposure Among HIV-Infected Ugandan Women.

    PubMed

    Woolf-King, Sarah E; Muyindike, Winnie; Hobbs, Marcia M; Kusasira, Adrine; Fatch, Robin; Emenyonu, Nneka; Johnson, Mallory O; Hahn, Judith A

    2017-07-01

    The practical feasibility of using prostate specific antigen (PSA) as a biomarker of semen exposure was examined among HIV-infected Ugandan women. Vaginal fluids were obtained with self-collected swabs and a qualitative rapid test (ABAcard ® p30) was used to detect PSA. Trained laboratory technicians processed samples on-site and positive PSA tests were compared to self-reported unprotected vaginal sex (UVS) in the last 48 h. A total of 77 women submitted 126 samples for PSA testing at up to three study visits. Of these samples, 31 % (n = 39/126) were PSA positive, and 64 % (n = 25/39) of the positive PSA samples were accompanied by self-report of no UVS at the study visit the PSA was collected. There were no reported difficulties with specimen collection, storage, or processing. These findings provide preliminary data on high levels of misreported UVS among HIV-infected Ugandan women using practically feasible methods for PSA collection and processing.

  8. Automated process for solvent separation of organic/inorganic substance

    DOEpatents

    Schweighardt, F.K.

    1986-07-29

    There is described an automated process for the solvent separation of organic/inorganic substances that operates continuously and unattended and eliminates potential errors resulting from subjectivity and the aging of the sample during analysis. In the process, metered amounts of one or more solvents are passed sequentially through a filter containing the sample under the direction of a microprocessor control apparatus. The mixture in the filter is agitated by ultrasonic cavitation for a timed period and the filtrate is collected. The filtrate of each solvent extraction is collected individually and the residue on the filter element is collected to complete the extraction process. 4 figs.

  9. Automated process for solvent separation of organic/inorganic substance

    DOEpatents

    Schweighardt, Frank K.

    1986-01-01

    There is described an automated process for the solvent separation of organic/inorganic substances that operates continuously and unattended and eliminates potential errors resulting from subjectivity and the aging of the sample during analysis. In the process, metered amounts of one or more solvents are passed sequentially through a filter containing the sample under the direction of a microprocessor control apparatus. The mixture in the filter is agitated by ultrasonic cavitation for a timed period and the filtrate is collected. The filtrate of each solvent extraction is collected individually and the residue on the filter element is collected to complete the extraction process.

  10. Blood Substrate Collection and Handling Procedures under Pseudo-Field Conditions: Evaluation of Suitability for Inflammatory Biomarker Measurement

    PubMed Central

    Danese, Andrea; Shalev, Idan; Williams, Benjamin S.; Caspi, Avshalom

    2015-01-01

    Routine incorporation of blood-based biomarker measurements in population studies has been hampered by challenges in obtaining samples suitable for biomarker assessment outside of laboratory settings. Here, we assessed the suitability of venous blood left unprocessed for four, 24 or 48 hours post-collection at either room temperature or 4°C for quantification of two biomarkers, Interleukin-6 (IL-6) and C-Reactive Protein (CRP). Blood samples were collected in both K2EDTA tubes and a dedicated plasma-preservation tube, P100. Dried Blood Spot (DBS) samples from the same subjects were also collected in order to compare delayed-processing plasma performance against a popular alternative collection method. K2EDTA mean plasma concentrations of both IL-6 and CRP were not significantly different from concentrations in plasma processed immediately; this was observed for tubes stored up to 48 hours pre-processing at either temperature. Concentrations of IL-6 measured in P100 tubes showed significant time-dependent increases when stored at room temperature; otherwise, levels of IL-6 and CRP were similar to those processed immediately. Levels of CRP in DBS were correlated with plasma CRP levels, even when pre-processed blood was stored for up to 48 hours. These data indicate that plasma is suitable for IL-6 and CRP estimation under data-collection conditions that involve processing delays. PMID:26652682

  11. Tightly integrated single- and multi-crystal data collection strategy calculation and parallelized data processing in JBluIce beamline control system

    PubMed Central

    Pothineni, Sudhir Babu; Venugopalan, Nagarajan; Ogata, Craig M.; Hilgart, Mark C.; Stepanov, Sergey; Sanishvili, Ruslan; Becker, Michael; Winter, Graeme; Sauter, Nicholas K.; Smith, Janet L.; Fischetti, Robert F.

    2014-01-01

    The calculation of single- and multi-crystal data collection strategies and a data processing pipeline have been tightly integrated into the macromolecular crystallographic data acquisition and beamline control software JBluIce. Both tasks employ wrapper scripts around existing crystallographic software. JBluIce executes scripts through a distributed resource management system to make efficient use of all available computing resources through parallel processing. The JBluIce single-crystal data collection strategy feature uses a choice of strategy programs to help users rank sample crystals and collect data. The strategy results can be conveniently exported to a data collection run. The JBluIce multi-crystal strategy feature calculates a collection strategy to optimize coverage of reciprocal space in cases where incomplete data are available from previous samples. The JBluIce data processing runs simultaneously with data collection using a choice of data reduction wrappers for integration and scaling of newly collected data, with an option for merging with pre-existing data. Data are processed separately if collected from multiple sites on a crystal or from multiple crystals, then scaled and merged. Results from all strategy and processing calculations are displayed in relevant tabs of JBluIce. PMID:25484844

  12. Tightly integrated single- and multi-crystal data collection strategy calculation and parallelized data processing in JBluIce beamline control system

    DOE PAGES

    Pothineni, Sudhir Babu; Venugopalan, Nagarajan; Ogata, Craig M.; ...

    2014-11-18

    The calculation of single- and multi-crystal data collection strategies and a data processing pipeline have been tightly integrated into the macromolecular crystallographic data acquisition and beamline control software JBluIce. Both tasks employ wrapper scripts around existing crystallographic software. JBluIce executes scripts through a distributed resource management system to make efficient use of all available computing resources through parallel processing. The JBluIce single-crystal data collection strategy feature uses a choice of strategy programs to help users rank sample crystals and collect data. The strategy results can be conveniently exported to a data collection run. The JBluIce multi-crystal strategy feature calculates amore » collection strategy to optimize coverage of reciprocal space in cases where incomplete data are available from previous samples. The JBluIce data processing runs simultaneously with data collection using a choice of data reduction wrappers for integration and scaling of newly collected data, with an option for merging with pre-existing data. Data are processed separately if collected from multiple sites on a crystal or from multiple crystals, then scaled and merged. Results from all strategy and processing calculations are displayed in relevant tabs of JBluIce.« less

  13. From Field to the Web: Management and Publication of Geoscience Samples in CSIRO Mineral Resources

    NASA Astrophysics Data System (ADS)

    Devaraju, A.; Klump, J. F.; Tey, V.; Fraser, R.; Reid, N.; Brown, A.; Golodoniuc, P.

    2016-12-01

    Inaccessible samples are an obstacle to the reproducibility of research and may cause waste of time and resources through duplication of sample collection and management. Within the Commonwealth Scientific and Industrial Research Organisation (CSIRO) Mineral Resources there are various research communities who collect or generate physical samples as part of their field studies and analytical processes. Materials can be varied and could be rock, soil, plant materials, water, and even synthetic materials. Given the wide range of applications in CSIRO, each researcher or project may follow their own method of collecting, curating and documenting samples. In many cases samples and their documentation are often only available to the sample collector. For example, the Australian Resources Research Centre stores rock samples and research collections dating as far back as the 1970s. Collecting these samples again would be prohibitively expensive and in some cases impossible because the site has been mined out. These samples would not be easily discoverable by others without an online sample catalog. We identify some of the organizational and technical challenges to provide unambiguous and systematic access to geoscience samples, and present their solutions (e.g., workflow, persistent identifier and tools). We present the workflow starting from field sampling to sample publication on the Web, and describe how the International Geo Sample Number (IGSN) can be applied to identify samples along the process. In our test case geoscientific samples are collected as part of the Capricorn Distal Footprints project, a collaboration project between the CSIRO, the Geological Survey of Western Australia, academic institutions and industry partners. We conclude by summarizing the values of our solutions in terms of sample management and publication.

  14. New Noble Gas Studies on Popping Rocks from the Mid-Atlantic Ridge near 14°N

    NASA Astrophysics Data System (ADS)

    Kurz, M. D.; Curtice, J.; Jones, M.; Péron, S.; Wanless, V. D.; Mittelstaedt, E. L.; Soule, S. A.; Klein, F.; Fornari, D. J.

    2017-12-01

    New Popping Rocks were recovered in situ on the Mid-Atlantic Ridge (MAR) near 13.77° N, using HOV Alvin on cruise AT33-03 in 2016 on RV Atlantis. We report new helium, neon, argon, and CO2 step-crushing measurements on a subset of the glass samples, with a focus on a new procedure to collect seafloor samples with minimal exposure to air. Glassy seafloor basalts were collected in sealed containers using the Alvin mechanical arm and transported to the surface without atmospheric exposure. On the ship, the seawater was drained, the volcanic glass was transferred to stainless steel ultra-high-vacuum containers (in an oxygen-free glove box), which were then evacuated using a turbo-molecular pump and sealed for transport under vacuum. All processing was carried out under a nitrogen atmosphere. A control sample was collected from each pillow outcrop and processed normally in air. The preliminary step-crushing measurements show that the anaerobically collected samples have systematically higher 20Ne/22Ne, 21Ne/22Ne and 40Ar/36Ar than the control samples. Helium abundances and isotopes are consistent between anaerobically collected samples and control samples. These results suggest that minimizing atmospheric exposure during sample processing can significantly reduce air contamination for heavy noble gases, providing a new option for seafloor sampling. Higher vesicle abundances appear to yield a greater difference in neon and argon isotopes between the anaerobic and control samples, suggesting that atmospheric contamination is related to vesicle abundance, possibly through micro-fractures. The new data show variability in the maximum mantle neon and argon isotopic compositions, and abundance ratios, suggesting that the samples experienced variable outgassing prior to eruption, and may represent different phases of a single eruption, or multiple eruptions.

  15. 40 CFR Table 9 to Subpart Hhhhhhh... - Procedures for Conducting Sampling of Stripped Resin and Process Wastewater

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Stripped Resin and Process Wastewater 9 Table 9 to Subpart HHHHHHH of Part 63 Protection of Environment... Wastewater For demonstrating . . . For the following emission points and types of processes . . . Collect.... Each process wastewater stream 3. Initial compliance N/A 1 grab sample 1 grab sample. 4. Continuous...

  16. 40 CFR Table 9 to Subpart Hhhhhhh... - Procedures for Conducting Sampling of Stripped Resin and Process Wastewater

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Stripped Resin and Process Wastewater 9 Table 9 to Subpart HHHHHHH of Part 63 Protection of Environment... Wastewater For demonstrating . . . For the following emission points and types of processes . . . Collect.... Each process wastewater stream 3. Initial compliance N/A 1 grab sample 1 grab sample. 4. Continuous...

  17. Apparatus and process for collection of gas and vapor samples

    DOEpatents

    Jackson, Dennis G [Augusta, GA; Peterson, Kurt D [Aiken, SC; Riha, Brian D [Augusta, GA

    2008-04-01

    A gas sampling apparatus and process is provided in which a standard crimping tool is modified by an attached collar. The collar permits operation of the crimping tool while also facilitating the introduction of a supply of gas to be introduced into a storage vial. The introduced gas supply is used to purge ambient air from a collection chamber and an interior of the sample vial. Upon completion of the purging operation, the vial is sealed using the crimping tool.

  18. Soil Gas Sample Handling: Evaluation of Water Removal and Sample Ganging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fritz, Brad G.; Abrecht, David G.; Hayes, James C.

    2016-10-31

    Soil gas sampling is currently conducted in support of Nuclear Test Ban treaty verification. Soil gas samples are collected and analyzed for isotopes of interest. Some issues that can impact sampling and analysis of these samples are excess moisture and sample processing time. Here we discuss three potential improvements to the current sampling protocol; a desiccant for water removal, use of molecular sieve to remove CO 2 from the sample during collection, and a ganging manifold to allow composite analysis of multiple samples.

  19. Development and Validation of Pathogen Environmental Monitoring Programs for Small Cheese Processing Facilities.

    PubMed

    Beno, Sarah M; Stasiewicz, Matthew J; Andrus, Alexis D; Ralyea, Robert D; Kent, David J; Martin, Nicole H; Wiedmann, Martin; Boor, Kathryn J

    2016-12-01

    Pathogen environmental monitoring programs (EMPs) are essential for food processing facilities of all sizes that produce ready-to-eat food products exposed to the processing environment. We developed, implemented, and evaluated EMPs targeting Listeria spp. and Salmonella in nine small cheese processing facilities, including seven farmstead facilities. Individual EMPs with monthly sample collection protocols were designed specifically for each facility. Salmonella was detected in only one facility, with likely introduction from the adjacent farm indicated by pulsed-field gel electrophoresis data. Listeria spp. were isolated from all nine facilities during routine sampling. The overall Listeria spp. (other than Listeria monocytogenes ) and L. monocytogenes prevalences in the 4,430 environmental samples collected were 6.03 and 1.35%, respectively. Molecular characterization and subtyping data suggested persistence of a given Listeria spp. strain in seven facilities and persistence of L. monocytogenes in four facilities. To assess routine sampling plans, validation sampling for Listeria spp. was performed in seven facilities after at least 6 months of routine sampling. This validation sampling was performed by independent individuals and included collection of 50 to 150 samples per facility, based on statistical sample size calculations. Two of the facilities had a significantly higher frequency of detection of Listeria spp. during the validation sampling than during routine sampling, whereas two other facilities had significantly lower frequencies of detection. This study provides a model for a science- and statistics-based approach to developing and validating pathogen EMPs.

  20. Efficiency of Different Sampling Tools for Aquatic Macroinvertebrate Collections in Malaysian Streams

    PubMed Central

    Ghani, Wan Mohd Hafezul Wan Abdul; Rawi, Che Salmah Md; Hamid, Suhaila Abd; Al-Shami, Salman Abdo

    2016-01-01

    This study analyses the sampling performance of three benthic sampling tools commonly used to collect freshwater macroinvertebrates. Efficiency of qualitative D-frame and square aquatic nets were compared to a quantitative Surber sampler in tropical Malaysian streams. The abundance and diversity of macroinvertebrates collected using each tool evaluated along with their relative variations (RVs). Each tool was used to sample macroinvertebrates from three streams draining different areas: a vegetable farm, a tea plantation and a forest reserve. High macroinvertebrate diversities were recorded using the square net and Surber sampler at the forested stream site; however, very low species abundance was recorded by the Surber sampler. Relatively large variations in the Surber sampler collections (RVs of 36% and 28%) were observed for the vegetable farm and tea plantation streams, respectively. Of the three sampling methods, the square net was the most efficient, collecting a greater diversity of macroinvertebrate taxa and a greater number of specimens (i.e., abundance) overall, particularly from the vegetable farm and the tea plantation streams (RV<25%). Fewer square net sample passes (<8 samples) were sufficient to perform a biological assessment of water quality, but each sample required a slightly longer processing time (±20 min) compared with those gathered via the other samplers. In conclusion, all three apparatuses were suitable for macroinvertebrate collection in Malaysian streams and gathered assemblages that resulted in the determination of similar biological water quality classes using the Family Biotic Index (FBI) and the Biological Monitoring Working Party (BMWP). However, despite a slightly longer processing time, the square net was more efficient (lowest RV) at collecting samples and more suitable for the collection of macroinvertebrates from deep, fast flowing, wadeable streams with coarse substrates. PMID:27019685

  1. Numerical simulations of regolith sampling processes

    NASA Astrophysics Data System (ADS)

    Schäfer, Christoph M.; Scherrer, Samuel; Buchwald, Robert; Maindl, Thomas I.; Speith, Roland; Kley, Wilhelm

    2017-07-01

    We present recent improvements in the simulation of regolith sampling processes in microgravity using the numerical particle method smooth particle hydrodynamics (SPH). We use an elastic-plastic soil constitutive model for large deformation and failure flows for dynamical behaviour of regolith. In the context of projected small body (asteroid or small moons) sample return missions, we investigate the efficiency and feasibility of a particular material sampling method: Brushes sweep material from the asteroid's surface into a collecting tray. We analyze the influence of different material parameters of regolith such as cohesion and angle of internal friction on the sampling rate. Furthermore, we study the sampling process in two environments by varying the surface gravity (Earth's and Phobos') and we apply different rotation rates for the brushes. We find good agreement of our sampling simulations on Earth with experiments and provide estimations for the influence of the material properties on the collecting rate.

  2. The Importance of Meteorite Collections to Sample Return Missions: Past, Present, and Future Considerations

    NASA Technical Reports Server (NTRS)

    Welzenbach, L. C.; McCoy, T. J.; Glavin, D. P.; Dworkin, J. P.; Abell, P. A.

    2012-01-01

    While much of the scientific community s current attention is drawn to sample return missions, it is the existing meteorite and cosmic dust collections that both provide the paradigms to be tested by these missions and the context for interpreting the results. Recent sample returns from the Stardust and Hayabusa missions provided us with new materials and insights about our Solar System history and processes. As an example, Stardust sampled CAIs among the population of cometary grains, requiring extensive and unexpected radial mixing in the early solar nebula. This finding would not have been possible, however, without extensive studies of meteoritic CAIs that established their high-temperature, inner Solar System formation. Samples returned by Stardust also revealed the first evidence of a cometary amino acid, a discovery that would not have been possible with current in situ flight instrument technology. The Hayabusa mission provided the final evidence linking ordinary chondrites and S asteroids, a hypothesis that developed from centuries of collection and laboratory and ground-based telescopic studies. In addition to these scientific findings, studies of existing meteorite collections have defined and refined the analytical techniques essential to studying returned samples. As an example, the fortuitous fall of the Allende CV3 and Murchison CM2 chondrites within months before the return of Apollo samples allowed testing of new state-of-the-art analytical facilities. The results of those studies not only prepared us to better study lunar materials, but unanticipated discoveries changed many of our concepts about the earliest history and processes of the solar nebula. This synergy between existing collections and future space exploration is certainly not limited to sample return missions. Laboratory studies confirmed the existence of meteorites from Mars and raised the provocative possibility of preservation of ancient microbial life. The laboratory studies in turn led to a new wave of Mars exploration that ultimately could lead to sample return focused on evidence for past or present life. This partnership between collections and missions will be increasingly important in the coming decades as we discover new questions to be addressed and identify targets for for both robotic and human exploration . Nowhere is this more true than in the ultimate search for the abiotic and biotic processes that produced life. Existing collections also provide the essential materials for developing and testing new analytical schemes to detect the rare markers of life and distinguish them from abiotic processes. Large collections of meteorites and the new types being identified within these collections, which come to us at a fraction of the cost of a sample return mission, will continue to shape the objectives of future missions and provide new ways of interpreting returned samples.

  3. Sampling and sample processing in pesticide residue analysis.

    PubMed

    Lehotay, Steven J; Cook, Jo Marie

    2015-05-13

    Proper sampling and sample processing in pesticide residue analysis of food and soil have always been essential to obtain accurate results, but the subject is becoming a greater concern as approximately 100 mg test portions are being analyzed with automated high-throughput analytical methods by agrochemical industry and contract laboratories. As global food trade and the importance of monitoring increase, the food industry and regulatory laboratories are also considering miniaturized high-throughput methods. In conjunction with a summary of the symposium "Residues in Food and Feed - Going from Macro to Micro: The Future of Sample Processing in Residue Analytical Methods" held at the 13th IUPAC International Congress of Pesticide Chemistry, this is an opportune time to review sampling theory and sample processing for pesticide residue analysis. If collected samples and test portions do not adequately represent the actual lot from which they came and provide meaningful results, then all costs, time, and efforts involved in implementing programs using sophisticated analytical instruments and techniques are wasted and can actually yield misleading results. This paper is designed to briefly review the often-neglected but crucial topic of sample collection and processing and put the issue into perspective for the future of pesticide residue analysis. It also emphasizes that analysts should demonstrate the validity of their sample processing approaches for the analytes/matrices of interest and encourages further studies on sampling and sample mass reduction to produce a test portion.

  4. Prevalence and level of Listeria monocytogenes and other Listeria sp. in ready-to-eat minimally processed and refrigerated vegetables.

    PubMed

    Kovačević, Mira; Burazin, Jelena; Pavlović, Hrvoje; Kopjar, Mirela; Piližota, Vlasta

    2013-04-01

    Minimally processed and refrigerated vegetables can be contaminated with Listeria species bacteria including Listeria monocytogenes due to extensive handling during processing or by cross contamination from the processing environment. The objective of this study was to examine the microbiological quality of ready-to-eat minimally processed and refrigerated vegetables from supermarkets in Osijek, Croatia. 100 samples of ready-to-eat vegetables collected from different supermarkets in Osijek, Croatia, were analyzed for presence of Listeria species and Listeria monocytogenes. The collected samples were cut iceberg lettuces (24 samples), other leafy vegetables (11 samples), delicatessen salads (23 samples), cabbage salads (19 samples), salads from mixed (17 samples) and root vegetables (6 samples). Listeria species was found in 20 samples (20 %) and Listeria monocytogenes was detected in only 1 sample (1 %) of cut red cabbage (less than 100 CFU/g). According to Croatian and EU microbiological criteria these results are satisfactory. However, the presence of Listeria species and Listeria monocytogenes indicates poor hygiene quality. The study showed that these products are often improperly labeled, since 24 % of analyzed samples lacked information about shelf life, and 60 % of samples lacked information about storage conditions. With regard to these facts, cold chain abruption with extended use after expiration date is a probable scenario. Therefore, the microbiological risk for consumers of ready-to-eat minimally processed and refrigerated vegetables is not completely eliminated.

  5. Geotechnical characterization of mined clay from Appalachian Ohio: challenges and implications for the clay mining industry.

    PubMed

    Moran, Anthony R; Hettiarachchi, Hiroshan

    2011-07-01

    Clayey soil found in coal mines in Appalachian Ohio is often sold to landfills for constructing Recompacted Soil Liners (RSL) in landfills. Since clayey soils possess low hydraulic conductivity, the suitability of mined clay for RSL in Ohio is first assessed by determining its clay content. When soil samples are tested in a laboratory, the same engineering properties are typically expected for the soils originated from the same source, provided that the testing techniques applied are standard, but mined clay from Appalachian Ohio has shown drastic differences in particle size distribution depending on the sampling and/or laboratory processing methods. Sometimes more than a 10 percent decrease in the clay content is observed in the samples collected at the stockpiles, compared to those collected through reverse circulation drilling. This discrepancy poses a challenge to geotechnical engineers who work on the prequalification process of RSL material as it can result in misleading estimates of the hydraulic conductivity of the samples. This paper describes a laboratory investigation conducted on mined clay from Appalachian Ohio to determine how and why the standard sampling and/or processing methods can affect the grain-size distributions. The variation in the clay content was determined to be due to heavy concentrations of shale fragments in the clayey soils. It was also concluded that, in order to obtain reliable grain size distributions from the samples collected at a stockpile of mined clay, the material needs to be processed using a soil grinder. Otherwise, the samples should be collected through drilling.

  6. Geotechnical Characterization of Mined Clay from Appalachian Ohio: Challenges and Implications for the Clay Mining Industry

    PubMed Central

    Moran, Anthony R.; Hettiarachchi, Hiroshan

    2011-01-01

    Clayey soil found in coal mines in Appalachian Ohio is often sold to landfills for constructing Recompacted Soil Liners (RSL) in landfills. Since clayey soils possess low hydraulic conductivity, the suitability of mined clay for RSL in Ohio is first assessed by determining its clay content. When soil samples are tested in a laboratory, the same engineering properties are typically expected for the soils originated from the same source, provided that the testing techniques applied are standard, but mined clay from Appalachian Ohio has shown drastic differences in particle size distribution depending on the sampling and/or laboratory processing methods. Sometimes more than a 10 percent decrease in the clay content is observed in the samples collected at the stockpiles, compared to those collected through reverse circulation drilling. This discrepancy poses a challenge to geotechnical engineers who work on the prequalification process of RSL material as it can result in misleading estimates of the hydraulic conductivity of the samples. This paper describes a laboratory investigation conducted on mined clay from Appalachian Ohio to determine how and why the standard sampling and/or processing methods can affect the grain-size distributions. The variation in the clay content was determined to be due to heavy concentrations of shale fragments in the clayey soils. It was also concluded that, in order to obtain reliable grain size distributions from the samples collected at a stockpile of mined clay, the material needs to be processed using a soil grinder. Otherwise, the samples should be collected through drilling. PMID:21845150

  7. Data Validation Package, April and June 2016 Groundwater and Surface Water Sampling at the Gunnison, Colorado, Processing Site, October 2016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Linard, Joshua; Campbell, Sam

    This event included annual sampling of groundwater and surface water locations at the Gunnison, Colorado, Processing Site. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for US Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and­ analysis-plan-us-department-energy-office-legacy-management-sites). Samples were collected from 28 monitoring wells, three domestic wells, and six surface locations in April at the processing site as specified in the draft 2010 Ground Water Compliance Action Plan for the Gunnison, Colorado, Processing Site. Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. Domestic wells 0476 and 0477 weremore » sampled in June because the homes were unoccupied in April, and the wells were not in use. Duplicate samples were collected from locations 0126, 0477, and 0780. One equipment blank was collected during this sampling event. Water levels were measured at all monitoring wells that were sampled. See Attachment 2, Trip Reports for additional details. The analytical data and associated qualifiers can be viewed in environmental database reports and are also available for viewing with dynamic mapping via the GEMS (Geospatial Environmental Mapping System) website at http://gems.lm.doe.gov/#. No issues were identified during the data validation process that requires additional action or follow-up. An assessment of anomalous data is included in Attachment 3. Interpretation and presentation of results, including an assessment ofthe natural flushing compliance strategy, will be reported in the upcoming 2016 Verification Monitoring Report. U.S.« less

  8. Dissolution actuated sample container

    DOEpatents

    Nance, Thomas A.; McCoy, Frank T.

    2013-03-26

    A sample collection vial and process of using a vial is provided. The sample collection vial has an opening secured by a dissolvable plug. When dissolved, liquids may enter into the interior of the collection vial passing along one or more edges of a dissolvable blocking member. As the blocking member is dissolved, a spring actuated closure is directed towards the opening of the vial which, when engaged, secures the vial contents against loss or contamination.

  9. Minimizing microbial contamination of sperm samples

    USGS Publications Warehouse

    Jenkins, Jill A.; Tiersch, Terrence R.; Green, Christopher C.

    2011-01-01

    Taken from the Methods section: With the collection and translocation of gametes from aquatic species, a potential hazard exists for microbial transfer. Contamination of semen can occur during collection, processing, storage, and transport. Some preventative measures are described below for limiting the spread and amplification of microorganisms such as bacteria, viruses, fungi, mycoplasmas, and parasites. Generally, sanitation during collection is essential. Materials and equipment used to freeze semen should be sterile. Following good practice guidelines for handling and processing samples collected for freezing is especially important for non-domestic animals where disease-free status cannot be guaranteed and unsophisticated technology is used (Russell et al. 1977).

  10. Effects of delayed laboratory processing on platelet serotonin levels.

    PubMed

    Sanner, Jennifer E; Frazier, Lorraine; Udtha, Malini

    2013-01-01

    Despite the availability of established guidelines for measuring platelet serotonin, these guidelines may be difficult to follow in a hospital setting where time to processing may vary from sample to sample. The purpose of this study was to evaluate the effect of the time to processing of human blood samples on the stability of the enzyme-linked immunosorbent assay (ELISA) for the determination of platelet serotonin levels in human plasma. Human blood samples collected from a convenience sample of eight healthy volunteers were analyzed to determine platelet serotonin levels from plasma collected in ethylene diamine tetra acetic acid (EDTA) tubes and stored at 4°C for 3 hr, 5 hr, 8 hr, and 12 hr. Refrigeration storage at 4°C for 3 hr, 5 hr, 8 hr, and 12 hr altered the platelet serotonin measurement when compared to immediate processing. The bias for the samples stored at 4°C for 3 hr was 102.3 (±217.39 ng/10(9) platelets), for 5 hr was 200.1 (±132.76 ng/10(9) platelets), for 8 hr was 146.9 (±221.41 ng/10(9) platelets), and for 12 hr was -67.6 (±349.60 ng/10(9) platelets). Results from this study show that accurate measurement of platelet serotonin levels is dependent on time to processing. Researchers should therefore follow a standardized laboratory guideline for obtaining immediate platelet serotonin levels after blood sample collection.

  11. A New Paradigm for Tissue Diagnostics: Tools and Techniques to Standardize Tissue Collection, Transport, and Fixation.

    PubMed

    Bauer, Daniel R; Otter, Michael; Chafin, David R

    2018-01-01

    Studying and developing preanalytical tools and technologies for the purpose of obtaining high-quality samples for histological assays is a growing field. Currently, there does not exist a standard practice for collecting, fixing, and monitoring these precious samples. There has been some advancement in standardizing collection for the highest profile tumor types, such as breast, where HER2 testing drives therapeutic decisions. This review examines the area of tissue collection, transport, and monitoring of formalin diffusion and details a prototype system that could be used to help standardize tissue collection efforts. We have surveyed recent primary literature sources and conducted several site visits to understand the most error-prone processes in histology laboratories. This effort identified errors that resulted from sample collection techniques and subsequent transport delays from the operating room (OR) to the histology laboratories. We have therefore devised a prototype sample collection and transport concept. The system consists of a custom data logger and cold transport box and takes advantage of a novel cold + warm (named 2 + 2) fixation method. This review highlights the beneficial aspects of standardizing tissue collection, fixation, and monitoring. In addition, a prototype system is introduced that could help standardize these processes and is compatible with use directly in the OR and from remote sites.

  12. Geochemical results from stream-water and stream-sediment samples collected in Colorado and New Mexico

    USGS Publications Warehouse

    Hageman, Philip L.; Todd, Andrew S.; Smith, Kathleen S.; DeWitt, Ed; Zeigler, Mathew P.

    2013-01-01

    Scientists from the U.S. Geological Survey are studying the relationship between watershed lithology and stream-water chemistry. As part of this effort, 60 stream-water samples and 43 corresponding stream-sediment samples were collected in 2010 and 2011 from locations in Colorado and New Mexico. Sample sites were selected from small to midsize watersheds composed of a high percentage of one rock type or geologic unit. Stream-water and stream-sediment samples were collected, processed, preserved, and analyzed in a consistent manner. This report releases geochemical data for this phase of the study.

  13. 40 CFR 65.113 - Standards: Sampling connection systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... be collected or captured. (c) Equipment design and operation. Each closed-purge, closed-loop, or... system; or (2) Collect and recycle the purged process fluid to a process; or (3) Be designed and operated to capture and transport all the purged process fluid to a control device that meets the requirements...

  14. 40 CFR 65.113 - Standards: Sampling connection systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... be collected or captured. (c) Equipment design and operation. Each closed-purge, closed-loop, or... system; or (2) Collect and recycle the purged process fluid to a process; or (3) Be designed and operated to capture and transport all the purged process fluid to a control device that meets the requirements...

  15. 40 CFR 65.113 - Standards: Sampling connection systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... be collected or captured. (c) Equipment design and operation. Each closed-purge, closed-loop, or... system; or (2) Collect and recycle the purged process fluid to a process; or (3) Be designed and operated to capture and transport all the purged process fluid to a control device that meets the requirements...

  16. Molecular epidemiology biomarkers-Sample collection and processing considerations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holland, Nina T.; Pfleger, Laura; Berger, Eileen

    2005-08-07

    Biomarker studies require processing and storage of numerous biological samples with the goals of obtaining a large amount of information and minimizing future research costs. An efficient study design includes provisions for processing of the original samples, such as cryopreservation, DNA isolation, and preparation of specimens for exposure assessment. Use of standard, two-dimensional and nanobarcodes and customized electronic databases assure efficient management of large sample collections and tracking results of data analyses. Standard operating procedures and quality control plans help to protect sample quality and to assure validity of the biomarker data. Specific state, federal and international regulations are inmore » place regarding research with human samples, governing areas including custody, safety of handling, and transport of human samples. Appropriate informed consent must be obtained from the study subjects prior to sample collection and confidentiality of results maintained. Finally, examples of three biorepositories of different scale (European Cancer Study, National Cancer Institute and School of Public Health Biorepository, University of California, Berkeley) are used to illustrate challenges faced by investigators and the ways to overcome them. New software and biorepository technologies are being developed by many companies that will help to bring biological banking to a new level required by molecular epidemiology of the 21st century.« less

  17. Laboratory diagnosis of gestational diabetes: An in silico investigation into the effects of pre-analytical processing on the diagnostic sensitivity and specificity of the oral glucose tolerance test.

    PubMed

    Mansell, Erin; Lunt, Helen; Docherty, Paul

    2017-06-01

    Delayed separation of red cells from plasma causes pre analytical glucose loss, which in turn results in an under-diagnosis of GDM (gestational diabetes) based on the OGTT (oral glucose tolerance test). In silico investigations may help laboratory decision making, when exploring pragmatic improvements to sample processing. Late pregnancy 0, 1 and 2h 75g OGTT values were obtained from two distinct populations of pregnant women: 1. Values derived from the HAPO (Hyperglycemia and Adverse Pregnancy Outcome) Study and 2. New Zealand women identified as at higher risk of GDM by their caregivers, undergoing OGTT during routine antenatal care. In both populations studied, in silico modelling focussed on the effects of pre-analytical delays in plasma separation, when using fluoride collection tubes. Using a model that 'batched' samples from the three OGTT collection times, diagnostic sensitivity was estimated as follows: 66.1% for HAPO research population and 48.4% for the 1305 women receiving routine antenatal care. If samples were not batched, but processed shortly after each blood sample was collected, then sensitivity increased to 81%. Exploration of a range of clinical and laboratory scenarios using in silico modelling, showed that delaying the processing of pregnancy OGTT samples, using batched sample collection into fluoride tubes, causes unacceptable loss of GDM diagnostic sensitivity across two distinct population groups. This modelling approach will hopefully provide information that helps with final decision making around improved laboratory processing techniques. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. Soda Geyser Geochemistry

    DOE Data Explorer

    Neupane, Ghanashyam; McLing, Travis

    2017-04-01

    These brine samples are collected from the Soda Geyser (a thermal feature, temperature ~30 C) in Soda Springs, Idaho. These samples also represent the overthrust brines typical of oil and gas plays in western Wyoming. Samples were collected from the source and along the flow channel at different distances from the source. By collecting and analyzing these samples we are able to increase the density and quality of data from the western Wyoming oil and gas plays. Furthermore, the sampling approach also helped determine the systematic variation in REE concentration with the sampling distance from the source. Several geochemical processes are at work along the flow channels, such as degassing, precipitation, sorption, etc.

  19. Efficient Research Design: Using Value-of-Information Analysis to Estimate the Optimal Mix of Top-down and Bottom-up Costing Approaches in an Economic Evaluation alongside a Clinical Trial.

    PubMed

    Wilson, Edward C F; Mugford, Miranda; Barton, Garry; Shepstone, Lee

    2016-04-01

    In designing economic evaluations alongside clinical trials, analysts are frequently faced with alternative methods of collecting the same data, the extremes being top-down ("gross costing") and bottom-up ("micro-costing") approaches. A priori, bottom-up approaches may be considered superior to top-down approaches but are also more expensive to collect and analyze. In this article, we use value-of-information analysis to estimate the efficient mix of observations on each method in a proposed clinical trial. By assigning a prior bivariate distribution to the 2 data collection processes, the predicted posterior (i.e., preposterior) mean and variance of the superior process can be calculated from proposed samples using either process. This is then used to calculate the preposterior mean and variance of incremental net benefit and hence the expected net gain of sampling. We apply this method to a previously collected data set to estimate the value of conducting a further trial and identifying the optimal mix of observations on drug costs at 2 levels: by individual item (process A) and by drug class (process B). We find that substituting a number of observations on process A for process B leads to a modest £ 35,000 increase in expected net gain of sampling. Drivers of the results are the correlation between the 2 processes and their relative cost. This method has potential use following a pilot study to inform efficient data collection approaches for a subsequent full-scale trial. It provides a formal quantitative approach to inform trialists whether it is efficient to collect resource use data on all patients in a trial or on a subset of patients only or to collect limited data on most and detailed data on a subset. © The Author(s) 2016.

  20. EVALUATION OF SOLID ADSORBENTS FOR THE COLLECTION AND ANALYSES OF AMBIENT BIOGENIC VOLATILE ORGANICS

    EPA Science Inventory

    Micrometeorological flux measurements of biogenic volatile organic compounds (BVOCs) usually require that large volumes of air be collected (whole air samples) or focused during the sampling process (cryogenic trapping or gas-solid partitioning on adsorbents) in order to achiev...

  1. Improved discovery of NEON data and samples though vocabularies, workflows, and web tools

    NASA Astrophysics Data System (ADS)

    Laney, C. M.; Elmendorf, S.; Flagg, C.; Harris, T.; Lunch, C. K.; Gulbransen, T.

    2017-12-01

    The National Ecological Observatory Network (NEON) is a continental-scale ecological observation facility sponsored by the National Science Foundation and operated by Battelle. NEON supports research on the impacts of invasive species, land use change, and environmental change on natural resources and ecosystems by gathering and disseminating a full suite of observational, instrumented, and airborne datasets from field sites across the U.S. NEON also collects thousands of samples from soil, water, and organisms every year, and partners with numerous institutions to analyze and archive samples. We have developed numerous new technologies to support processing and discovery of this highly diverse collection of data. These technologies include applications for data collection and sample management, processing pipelines specific to each collection system (field observations, installed sensors, and airborne instruments), and publication pipelines. NEON data and metadata are discoverable and downloadable via both a public API and data portal. We solicit continued engagement and advice from the informatics and environmental research communities, particularly in the areas of data versioning, usability, and visualization.

  2. The UK Biobank sample handling and storage validation studies.

    PubMed

    Peakman, Tim C; Elliott, Paul

    2008-04-01

    and aims UK Biobank is a large prospective study in the United Kingdom to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. It involves the collection of blood and urine from 500 000 individuals aged between 40 and 69 years. How the samples are collected, processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. A series of validation studies was recommended to test the robustness of the draft sample handling and storage protocol. Samples of blood and urine were collected from 40 healthy volunteers and either processed immediately according to the protocol or maintained at specified temperatures (4 degrees C for all tubes with the exception of vacutainers containing acid citrate dextrose that were maintained at 18 degrees C) for 12, 24 or 36 h prior to processing. A further sample was maintained for 24 h at 4 degrees C, processed and the aliquots frozen at -80 degrees C for 20 days and then thawed under controlled conditions. The stability of the samples was compared for the different times in a wide variety of assays. The samples maintained at 4 degrees C were stable for at least 24 h after collection for a wide range of assays. Small but significant changes were observed in metabonomic studies in samples maintained at 4 degrees C for 36 h. There was no degradation of the samples for a range of biochemical assays after short-term freezing and thawing under controlled conditions. Whole blood maintained at 18 degrees C for 24 h in vacutainers containing acid citrate dextrose is suitable for viral immortalization techniques. The validation studies reported in this supplement provide justification for the sample handling and storage procedures adopted in the UK Biobank project.

  3. Proximate composition of poultry processing wastewater particulate matter from broiler slaughter plants.

    PubMed

    Kiepper, B H; Merka, W C; Fletcher, D L

    2008-08-01

    An experiment was conducted to compare the proximate composition of particulate matter recovered from poultry processing wastewater (PPW) generated by broiler slaughter plants. Poultry processing wastewater is the cumulative wastewater stream generated during the processing of poultry following primary and secondary physical screening (typically to 500 mum) that removes gross offal. Composite samples of PPW from 3 broiler slaughter plants (southeast United States) were collected over 8 consecutive weeks. All 3 broiler slaughter plants process young chickens with an average live weight of 2.0 kg. At each plant, a single 72-L composite sample was collected using an automatic sampler programmed to collect 1 L of wastewater every 20 min for 24 h during one normal processing day each week. Each composite sample was thoroughly mixed, and 60 L was passed through a series of sieves (2.0 mm, 1.0 mm, 500 mum, and 53 mum). The amount of particulate solids collected on the 2.0 mm, 1.0 mm, and 500 mum sieves was insignificant. The solids recovered from the 53-mum sieve were subjected to proximate analysis to determine percent moisture, fat, protein, ash, and fiber. The average percentages of fat, protein, ash, and fiber for all samples on a dry-weight basis were 55.3, 27.1, 6.1, and 4.1, respectively. Fat made up over half of the dry-weight matter recovered, representing PPW particulate matter between 500 and 53 mum. Despite the variation in number of birds processed daily, further processing operations, and number and type of wastewater screens utilized, there were no significance differences in percentage of fat and fiber between the slaughter plants. There were significant differences in percent protein and ash between the slaughter plants.

  4. A high-throughput core sampling device for the evaluation of maize stalk composition

    PubMed Central

    2012-01-01

    Background A major challenge in the identification and development of superior feedstocks for the production of second generation biofuels is the rapid assessment of biomass composition in a large number of samples. Currently, highly accurate and precise robotic analysis systems are available for the evaluation of biomass composition, on a large number of samples, with a variety of pretreatments. However, the lack of an inexpensive and high-throughput process for large scale sampling of biomass resources is still an important limiting factor. Our goal was to develop a simple mechanical maize stalk core sampling device that can be utilized to collect uniform samples of a dimension compatible with robotic processing and analysis, while allowing the collection of hundreds to thousands of samples per day. Results We have developed a core sampling device (CSD) to collect maize stalk samples compatible with robotic processing and analysis. The CSD facilitates the collection of thousands of uniform tissue cores consistent with high-throughput analysis required for breeding, genetics, and production studies. With a single CSD operated by one person with minimal training, more than 1,000 biomass samples were obtained in an eight-hour period. One of the main advantages of using cores is the high level of homogeneity of the samples obtained and the minimal opportunity for sample contamination. In addition, the samples obtained with the CSD can be placed directly into a bath of ice, dry ice, or liquid nitrogen maintaining the composition of the biomass sample for relatively long periods of time. Conclusions The CSD has been demonstrated to successfully produce homogeneous stalk core samples in a repeatable manner with a throughput substantially superior to the currently available sampling methods. Given the variety of maize developmental stages and the diversity of stalk diameter evaluated, it is expected that the CSD will have utility for other bioenergy crops as well. PMID:22548834

  5. Instrument to collect fogwater for chemical analysis

    NASA Astrophysics Data System (ADS)

    Jacob, Daniel J.; Waldman, Jed M.; Haghi, Mehrdad; Hoffmann, Michael R.; Flagan, Richard C.

    1985-06-01

    An instrument is presented which collects large samples of ambient fogwater by impaction of droplets on a screen. The collection efficiency of the instrument is determined as a function of droplet size, and it is shown that fog droplets in the range 3-100-μm diameter are efficiently collected. No significant evaporation or condensation occurs at any stage of the collection process. Field testing indicates that samples collected are representative of the ambient fogwater. The instrument may easily be automated, and is suitable for use in routine air quality monitoring programs.

  6. Comparison of stool collection on site versus at home in a population-based study : feasibility and participants' preference in Pretest 2 of the German National Cohort.

    PubMed

    Schultze, A; Akmatov, M K; Andrzejak, M; Karras, N; Kemmling, Y; Maulhardt, A; Wieghold, S; Ahrens, W; Günther, K; Schlenz, H; Krause, G; Pessler, F

    2014-11-01

    For certain laboratory investigations it is necessary to obtain native stool samples and process them within a narrow time window at the point of contact or a nearby laboratory. However, it is not known whether it is feasible to obtain stool samples from asymptomatic individuals during an appointment in a study center (SC). We therefore compared participants' preference, feasibility and acceptance of stool sample collection during the appointment at the study center (on-site sampling) to collection at home after the appointment. The study was conducted at two sites in Northern Germany (Bremen, n = 156; Hannover, n = 147) during the Pretest 2 phase of the German National Cohort (GNC), drawing upon a randomly selected population supplemented by a small convenience sample. In the study center, the participants were given the choice to provide a stool sample during the appointment or to collect a sample later at home and return it by mail. In all, 303 of the 351 participants (86 %) of Pretest 2 at these sites participated in this feasibility study. Only 7.9 % (24/303) of the participants chose on-site collection, whereas 92 % (279/303) chose at-home collection. There were significant differences between the two study sites in that 14 % (21/147) of participants in Hannover and 2 % (3/156) of participants in Bremen chose on-site collection. Compliance was high in both groups, as 100 % (24/24) and 98 % (272/279) of participants in the on-site and at-home groups, respectively, provided complete samples. Both methods were highly accepted, as 92 % of the participants in each group (22/24 and 227/248) stated that stool collection at the respective site was acceptable. When given a choice, most participants in this population-based study preferred home collection of stool samples to collection in the study center. Thus, native stool samples for immediate processing in the study center may potentially be obtained only from a subpopulation of participants, which may lead to selection bias. Home collection, on the other hand, proved to be a highly feasible method for studies that do not require freshly collected native stool.

  7. Dynamic Method for Identifying Collected Sample Mass

    NASA Technical Reports Server (NTRS)

    Carson, John

    2008-01-01

    G-Sample is designed for sample collection missions to identify the presence and quantity of sample material gathered by spacecraft equipped with end effectors. The software method uses a maximum-likelihood estimator to identify the collected sample's mass based on onboard force-sensor measurements, thruster firings, and a dynamics model of the spacecraft. This makes sample mass identification a computation rather than a process requiring additional hardware. Simulation examples of G-Sample are provided for spacecraft model configurations with a sample collection device mounted on the end of an extended boom. In the absence of thrust knowledge errors, the results indicate that G-Sample can identify the amount of collected sample mass to within 10 grams (with 95-percent confidence) by using a force sensor with a noise and quantization floor of 50 micrometers. These results hold even in the presence of realistic parametric uncertainty in actual spacecraft inertia, center-of-mass offset, and first flexibility modes. Thrust profile knowledge is shown to be a dominant sensitivity for G-Sample, entering in a nearly one-to-one relationship with the final mass estimation error. This means thrust profiles should be well characterized with onboard accelerometers prior to sample collection. An overall sample-mass estimation error budget has been developed to approximate the effect of model uncertainty, sensor noise, data rate, and thrust profile error on the expected estimate of collected sample mass.

  8. Biopolymers for sample collection, protection, and preservation.

    PubMed

    Sorokulova, Iryna; Olsen, Eric; Vodyanoy, Vitaly

    2015-07-01

    One of the principal challenges in the collection of biological samples from air, water, and soil matrices is that the target agents are not stable enough to be transferred from the collection point to the laboratory of choice without experiencing significant degradation and loss of viability. At present, there is no method to transport biological samples over considerable distances safely, efficiently, and cost-effectively without the use of ice or refrigeration. Current techniques of protection and preservation of biological materials have serious drawbacks. Many known techniques of preservation cause structural damages, so that biological materials lose their structural integrity and viability. We review applications of a novel bacterial preservation process, which is nontoxic and water soluble and allows for the storage of samples without refrigeration. The method is capable of protecting the biological sample from the effects of environment for extended periods of time and then allows for the easy release of these collected biological materials from the protective medium without structural or DNA damage. Strategies for sample collection, preservation, and shipment of bacterial, viral samples are described. The water-soluble polymer is used to immobilize the biological material by replacing the water molecules within the sample with molecules of the biopolymer. The cured polymer results in a solid protective film that is stable to many organic solvents, but quickly removed by the application of the water-based solution. The process of immobilization does not require the use of any additives, accelerators, or plastifiers and does not involve high temperature or radiation to promote polymerization.

  9. COLDEX-86: Fluid and Electrolyte Changes during Prolonged Cold Water Immersion

    DTIC Science & Technology

    1990-12-01

    4 Urine and blood collections .................. ..................... 5 Sample processing and biochemical analyses...and decaffeinated tea and coffee. Ingestion of fluids was encouraged. After completing the immersion, 16 oz of warm apple or cranberry juice was...day. Sample processing and biochemical analyses. Blood samples (25 ml) were drawn from an antecubital vein with minimum stasis. Each sample was divided

  10. Water-quality data for water- and wastewater-treatment plants along the Red River of the North, North Dakota and Minnesota, January through October 2006

    USGS Publications Warehouse

    Damschen, William C.; Hansel, John A.; Nustad, Rochelle A.

    2008-01-01

    From January through October 2006, six sets of water-quality samples were collected at 28 sites, which included inflow and outflow from seven major municipal water-treatment plants (14 sites) and influent and effluent samples from seven major municipal wastewater treatment plants (14 sites) along the Red River of the North in North Dakota and Minnesota. Samples were collected in cooperation with the Bureau of Reclamation for use in the development of return-flow boundary conditions in a 2006 water-quality model for the Red River of the North. All samples were analyzed for nutrients and major ions. For one set of effluent samples from each of the wastewater-treatment plants, water was analyzed for Eschirichia coli, fecal coliform, 20-day biochemical oxygen demand, 20-day nitrogenous biochemical oxygen demand, total organic carbon, and dissolved organic carbon. In general, results from the field equipment blank and replicate samples indicate that the overall process of sample collection, processing, and analysis did not introduce substantial contamination and that consistent results were obtained.

  11. Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure using a laser sensor

    DOEpatents

    Van Berkel, Gary J [Clinton, TN; Kertesz, Vilmos [Knoxville, TN

    2012-02-21

    A system and method utilizes distance-measuring equipment including a laser sensor for controlling the collection instrument-to-surface distance during a sample collection process for use, for example, with mass spectrometric detection. The laser sensor is arranged in a fixed positional relationship with the collection instrument, and a signal is generated by way of the laser sensor which corresponds to the actual distance between the laser sensor and the surface. The actual distance between the laser sensor and the surface is compared to a target distance between the laser sensor and the surface when the collection instrument is arranged at a desired distance from the surface for sample collecting purposes, and adjustments are made, if necessary, so that the actual distance approaches the target distance.

  12. High-frequency, long-duration water sampling in acid mine drainage studies: a short review of current methods and recent advances in automated water samplers

    USGS Publications Warehouse

    Chapin, Thomas

    2015-01-01

    Hand-collected grab samples are the most common water sampling method but using grab sampling to monitor temporally variable aquatic processes such as diel metal cycling or episodic events is rarely feasible or cost-effective. Currently available automated samplers are a proven, widely used technology and typically collect up to 24 samples during a deployment. However, these automated samplers are not well suited for long-term sampling in remote areas or in freezing conditions. There is a critical need for low-cost, long-duration, high-frequency water sampling technology to improve our understanding of the geochemical response to temporally variable processes. This review article will examine recent developments in automated water sampler technology and utilize selected field data from acid mine drainage studies to illustrate the utility of high-frequency, long-duration water sampling.

  13. Polonium-210 in the environment around a radioactive waste disposal area and phosphate ore processing plant.

    PubMed

    Arthur, W J; Markham, O D

    1984-04-01

    Polonium-210 concentrations were determined for soil, vegetation and small mammal tissues collected at a solid radioactive waste disposal area, near a phosphate ore processing plant and at two rural areas in southeastern Idaho. Polonium concentrations in media sampled near the radioactive waste disposal facility were equal to or less than values from rural area samples, indicating that disposal of solid radioactive waste at the Idaho National Engineering Laboratory Site has not resulted in increased environmental levels of polonium. Concentrations of 210Po in soils, deer mice hide and carcass samples collected near the phosphate processing plant were statistically (P less than or equal to 0.05) greater than the other sampling locations; however, the mean 210Po concentration in soils and small mammal tissues from sampling areas near the phosphate plant were only four and three times greater, respectively, than control values. No statistical (P greater than 0.05) difference was observed for 210Po concentrations in vegetation among any of the sampling locations.

  14. Sampling design and procedures for fixed surface-water sites in the Georgia-Florida coastal plain study unit, 1993

    USGS Publications Warehouse

    Hatzell, H.H.; Oaksford, E.T.; Asbury, C.E.

    1995-01-01

    The implementation of design guidelines for the National Water-Quality Assessment (NAWQA) Program has resulted in the development of new sampling procedures and the modification of existing procedures commonly used in the Water Resources Division of the U.S. Geological Survey. The Georgia-Florida Coastal Plain (GAFL) study unit began the intensive data collection phase of the program in October 1992. This report documents the implementation of the NAWQA guidelines by describing the sampling design and procedures for collecting surface-water samples in the GAFL study unit in 1993. This documentation is provided for agencies that use water-quality data and for future study units that will be entering the intensive phase of data collection. The sampling design is intended to account for large- and small-scale spatial variations, and temporal variations in water quality for the study area. Nine fixed sites were selected in drainage basins of different sizes and different land-use characteristics located in different land-resource provinces. Each of the nine fixed sites was sampled regularly for a combination of six constituent groups composed of physical and chemical constituents: field measurements, major ions and metals, nutrients, organic carbon, pesticides, and suspended sediments. Some sites were also sampled during high-flow conditions and storm events. Discussion of the sampling procedure is divided into three phases: sample collection, sample splitting, and sample processing. A cone splitter was used to split water samples for the analysis of the sampling constituent groups except organic carbon from approximately nine liters of stream water collected at four fixed sites that were sampled intensively. An example of the sample splitting schemes designed to provide the sample volumes required for each sample constituent group is described in detail. Information about onsite sample processing has been organized into a flowchart that describes a pathway for each of the constituent groups.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andrews, V.E.

    Naturally occurring radioactivity was measured in the atmospheric emissions and process materials of a thermal phosphate (elemental phosphorus) plant. Representative exhaust stack samples were collected from each process in the plant. The phosphate ore contained 12 to 20 parts per million uranium. Processes, emission points, and emission controls are described. Radioactivity concentrations and emission rates from the sources sampled are given.

  16. Pre-analytical issues in the haemostasis laboratory: guidance for the clinical laboratories.

    PubMed

    Magnette, A; Chatelain, M; Chatelain, B; Ten Cate, H; Mullier, F

    2016-01-01

    Ensuring quality has become a daily requirement in laboratories. In haemostasis, even more than in other disciplines of biology, quality is determined by a pre-analytical step that encompasses all procedures, starting with the formulation of the medical question, and includes patient preparation, sample collection, handling, transportation, processing, and storage until time of analysis. This step, based on a variety of manual activities, is the most vulnerable part of the total testing process and is a major component of the reliability and validity of results in haemostasis and constitutes the most important source of erroneous or un-interpretable results. Pre-analytical errors may occur throughout the testing process and arise from unsuitable, inappropriate or wrongly handled procedures. Problems may arise during the collection of blood specimens such as misidentification of the sample, use of inadequate devices or needles, incorrect order of draw, prolonged tourniquet placing, unsuccessful attempts to locate the vein, incorrect use of additive tubes, collection of unsuitable samples for quality or quantity, inappropriate mixing of a sample, etc. Some factors can alter the result of a sample constituent after collection during transportation, preparation and storage. Laboratory errors can often have serious adverse consequences. Lack of standardized procedures for sample collection accounts for most of the errors encountered within the total testing process. They can also have clinical consequences as well as a significant impact on patient care, especially those related to specialized tests as these are often considered as "diagnostic". Controlling pre-analytical variables is critical since this has a direct influence on the quality of results and on their clinical reliability. The accurate standardization of the pre-analytical phase is of pivotal importance for achieving reliable results of coagulation tests and should reduce the side effects of the influence factors. This review is a summary of the most important recommendations regarding the importance of pre-analytical factors for coagulation testing and should be a tool to increase awareness about the importance of pre-analytical factors for coagulation testing.

  17. ESDA®-Lite collection of DNA from latent fingerprints on documents.

    PubMed

    Plaza, Dane T; Mealy, Jamia L; Lane, J Nicholas; Parsons, M Neal; Bathrick, Abigail S; Slack, Donia P

    2015-05-01

    The ability to detect and non-destructively collect biological samples for DNA processing would benefit the forensic community by preserving the physical integrity of evidentiary items for more thorough evaluations by other forensic disciplines. The Electrostatic Detection Apparatus (ESDA®) was systemically evaluated for its ability to non-destructively collect DNA from latent fingerprints deposited on various paper substrates for short tandem repeat (STR) DNA profiling. Fingerprints were deposited on a variety of paper substrates that included resume paper, cotton paper, magazine paper, currency, copy paper, and newspaper. Three DNA collection techniques were performed: ESDA collection, dry swabbing, and substrate cutting. Efficacy of each collection technique was evaluated by the quantity of DNA present in each sample and the percent profile generated by each sample. Both the ESDA and dry swabbing non-destructive sampling techniques outperformed the destructive methodology of substrate cutting. A greater number of full profiles were generated from samples collected with the non-destructive dry swabbing collection technique than were generated from samples collected with the ESDA; however, the ESDA also allowed the user to visualize the area of interest while non-destructively collecting the biological material. The ability to visualize the biological material made sampling straightforward and eliminated the need for numerous, random swabbings/cuttings. Based on these results, the evaluated non-destructive ESDA collection technique has great potential for real-world forensic implementation. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. ASSESSMENT OF THE BACTERIOLOGICAL QUALITY OF COMPOST FROM A YARD WASTE PROCESSING FACILITY

    EPA Science Inventory

    Citizen concern over possible pathogenic microorganism contamination in compost and in a runoff collection pond prompted a U.S. Environmental Protection Agency (EPA) investigation. One out of eight samples collected from the distribution pile at a yard waste compost processing f...

  19. A microfluidic platform for precision small-volume sample processing and its use to size separate biological particles with an acoustic microdevice [Precision size separation of biological particles in small-volume samples by an acoustic microfluidic system

    DOE PAGES

    Fong, Erika J.; Huang, Chao; Hamilton, Julie; ...

    2015-11-23

    Here, a major advantage of microfluidic devices is the ability to manipulate small sample volumes, thus reducing reagent waste and preserving precious sample. However, to achieve robust sample manipulation it is necessary to address device integration with the macroscale environment. To realize repeatable, sensitive particle separation with microfluidic devices, this protocol presents a complete automated and integrated microfluidic platform that enables precise processing of 0.15–1.5 ml samples using microfluidic devices. Important aspects of this system include modular device layout and robust fixtures resulting in reliable and flexible world to chip connections, and fully-automated fluid handling which accomplishes closed-loop sample collection,more » system cleaning and priming steps to ensure repeatable operation. Different microfluidic devices can be used interchangeably with this architecture. Here we incorporate an acoustofluidic device, detail its characterization, performance optimization, and demonstrate its use for size-separation of biological samples. By using real-time feedback during separation experiments, sample collection is optimized to conserve and concentrate sample. Although requiring the integration of multiple pieces of equipment, advantages of this architecture include the ability to process unknown samples with no additional system optimization, ease of device replacement, and precise, robust sample processing.« less

  20. Application of binomial and multinomial probability statistics to the sampling design process of a global grain tracing and recall system

    USDA-ARS?s Scientific Manuscript database

    Small, coded, pill-sized tracers embedded in grain are proposed as a method for grain traceability. A sampling process for a grain traceability system was designed and investigated by applying probability statistics using a science-based sampling approach to collect an adequate number of tracers fo...

  1. Chapter A5. Processing of Water Samples

    USGS Publications Warehouse

    Wilde, Franceska D.; Radtke, Dean B.; Gibs, Jacob; Iwatsubo, Rick T.

    1999-01-01

    The National Field Manual for the Collection of Water-Quality Data (National Field Manual) describes protocols and provides guidelines for U.S. Geological Survey (USGS) personnel who collect data used to assess the quality of the Nation's surface-water and ground-water resources. This chapter addresses methods to be used in processing water samples to be analyzed for inorganic and organic chemical substances, including the bottling of composite, pumped, and bailed samples and subsamples; sample filtration; solid-phase extraction for pesticide analyses; sample preservation; and sample handling and shipping. Each chapter of the National Field Manual is published separately and revised periodically. Newly published and revised chapters will be announced on the USGS Home Page on the World Wide Web under 'New Publications of the U.S. Geological Survey.' The URL for this page is http:/ /water.usgs.gov/lookup/get?newpubs.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fong, Erika J.; Huang, Chao; Hamilton, Julie

    Here, a major advantage of microfluidic devices is the ability to manipulate small sample volumes, thus reducing reagent waste and preserving precious sample. However, to achieve robust sample manipulation it is necessary to address device integration with the macroscale environment. To realize repeatable, sensitive particle separation with microfluidic devices, this protocol presents a complete automated and integrated microfluidic platform that enables precise processing of 0.15–1.5 ml samples using microfluidic devices. Important aspects of this system include modular device layout and robust fixtures resulting in reliable and flexible world to chip connections, and fully-automated fluid handling which accomplishes closed-loop sample collection,more » system cleaning and priming steps to ensure repeatable operation. Different microfluidic devices can be used interchangeably with this architecture. Here we incorporate an acoustofluidic device, detail its characterization, performance optimization, and demonstrate its use for size-separation of biological samples. By using real-time feedback during separation experiments, sample collection is optimized to conserve and concentrate sample. Although requiring the integration of multiple pieces of equipment, advantages of this architecture include the ability to process unknown samples with no additional system optimization, ease of device replacement, and precise, robust sample processing.« less

  3. Fitting distributions to microbial contamination data collected with an unequal probability sampling design.

    PubMed

    Williams, M S; Ebel, E D; Cao, Y

    2013-01-01

    The fitting of statistical distributions to microbial sampling data is a common application in quantitative microbiology and risk assessment applications. An underlying assumption of most fitting techniques is that data are collected with simple random sampling, which is often times not the case. This study develops a weighted maximum likelihood estimation framework that is appropriate for microbiological samples that are collected with unequal probabilities of selection. A weighted maximum likelihood estimation framework is proposed for microbiological samples that are collected with unequal probabilities of selection. Two examples, based on the collection of food samples during processing, are provided to demonstrate the method and highlight the magnitude of biases in the maximum likelihood estimator when data are inappropriately treated as a simple random sample. Failure to properly weight samples to account for how data are collected can introduce substantial biases into inferences drawn from the data. The proposed methodology will reduce or eliminate an important source of bias in inferences drawn from the analysis of microbial data. This will also make comparisons between studies and the combination of results from different studies more reliable, which is important for risk assessment applications. © 2012 No claim to US Government works.

  4. Field guide for collecting samples for analysis of volatile organic compounds in stream water for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.

    1997-01-01

    For many years, stream samples for analysis of volatile organic compounds have been collected without specific guidelines or a sampler designed to avoid analyte loss. In 1996, the U.S. Geological Survey's National Water-Quality Assessment Program began aggressively monitoring urban stream-water for volatile organic compounds. To assure representative samples and consistency in collection procedures, a specific sampler was designed to collect samples for analysis of volatile organic compounds in stream water. This sampler, and the collection procedures, were tested in the laboratory and in the field for compound loss, contamination, sample reproducibility, and functional capabilities. This report describes that sampler and its use, and outlines field procedures specifically designed to provide contaminant-free, reproducible volatile organic compound data from stream-water samples. These guidelines and the equipment described represent a significant change in U.S. Geological Survey instructions for collecting and processing stream-water samples for analysis of volatile organic compounds. They are intended to produce data that are both defensible and interpretable, particularly for concentrations below the microgram-per-liter level. The guidelines also contain detailed recommendations for quality-control samples.

  5. 78 FR 69103 - 30-Day Notice of Proposed Information Collection: Quality Control for Rental Assistance Subsidy...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-18

    ... Information Collection: Quality Control for Rental Assistance Subsidy Determinations AGENCY: Office of the... Collection Title of Information Collection: Quality Control for Rental Assistance Subsidy Determinations. OMB... Quality Control process involves selecting a nationally representative sample of assisted households to...

  6. Aqueous Processing of Atmospheric Organic Particles in Cloud Water Collected via Aircraft Sampling.

    PubMed

    Boone, Eric J; Laskin, Alexander; Laskin, Julia; Wirth, Christopher; Shepson, Paul B; Stirm, Brian H; Pratt, Kerri A

    2015-07-21

    Cloudwater and below-cloud atmospheric particle samples were collected onboard a research aircraft during the Southern Oxidant and Aerosol Study (SOAS) over a forested region of Alabama in June 2013. The organic molecular composition of the samples was studied to gain insights into the aqueous-phase processing of organic compounds within cloud droplets. High resolution mass spectrometry (HRMS) with nanospray desorption electrospray ionization (nano-DESI) and direct infusion electrospray ionization (ESI) were utilized to compare the organic composition of the particle and cloudwater samples, respectively. Isoprene and monoterpene-derived organosulfates and oligomers were identified in both the particles and cloudwater, showing the significant influence of biogenic volatile organic compound oxidation above the forested region. While the average O:C ratios of the organic compounds were similar between the atmospheric particle and cloudwater samples, the chemical composition of these samples was quite different. Specifically, hydrolysis of organosulfates and formation of nitrogen-containing compounds were observed for the cloudwater when compared to the atmospheric particle samples, demonstrating that cloud processing changes the composition of organic aerosol.

  7. Aqueous Processing of Atmospheric Organic Particles in Cloud Water Collected via Aircraft Sampling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boone, Eric J.; Laskin, Alexander; Laskin, Julia

    2015-07-21

    Cloud water and below-cloud atmospheric particle samples were collected onboard a research aircraft during the Southern Oxidant and Aerosol Study (SOAS) over a forested region of Alabama in June 2013. The organic molecular composition of the samples was studied to gain insights into the aqueous-phase processing of organic compounds within cloud droplets. High resolution mass spectrometry with nanospray desorption electrospray ionization and direct infusion electrospray ionization were utilized to compare the organic composition of the particle and cloud water samples, respectively. Isoprene and monoterpene-derived organosulfates and oligomers were identified in both the particles and cloud water, showing the significant influencemore » of biogenic volatile organic compound oxidation above the forested region. While the average O:C ratios of the organic compounds were similar between the atmospheric particle and cloud water samples, the chemical composition of these samples was quite different. Specifically, hydrolysis of organosulfates and formation of nitrogen-containing compounds were observed for the cloud water when compared to the atmospheric particle samples, demonstrating that cloud processing changes the composition of organic aerosol.« less

  8. World Endometriosis Research Foundation Endometriosis Phenome and Biobanking Harmonisation Project: IV. Tissue collection, processing, and storage in endometriosis research

    PubMed Central

    Fassbender, Amelie; Rahmioglu, Nilufer; Vitonis, Allison F.; Viganò, Paola; Giudice, Linda C.; D’Hooghe, Thomas M.; Hummelshoj, Lone; Adamson, G. David; Becker, Christian M.; Missmer, Stacey A.; Zondervan, Krina T.; Adamson, G.D.; Allaire, C.; Anchan, R.; Becker, C.M.; Bedaiwy, M.A.; Buck Louis, G.M.; Calhaz-Jorge, C.; Chwalisz, K.; D'Hooghe, T.M.; Fassbender, A.; Faustmann, T.; Fazleabas, A.T.; Flores, I.; Forman, A.; Fraser, I.; Giudice, L.C.; Gotte, M.; Gregersen, P.; Guo, S.-W.; Harada, T.; Hartwell, D.; Horne, A.W.; Hull, M.L.; Hummelshoj, L.; Ibrahim, M.G.; Kiesel, L.; Laufer, M.R.; Machens, K.; Mechsner, S.; Missmer, S.A.; Montgomery, G.W.; Nap, A.; Nyegaard, M.; Osteen, K.G.; Petta, C.A.; Rahmioglu, N.; Renner, S.P.; Riedlinger, J.; Roehrich, S.; Rogers, P.A.; Rombauts, L.; Salumets, A.; Saridogan, E.; Seckin, T.; Stratton, P.; Sharpe-Timms, K.L.; Tworoger, S.; Vigano, P.; Vincent, K.; Vitonis, A.F.; Wienhues-Thelen, U.-H.; Yeung, P.P.; Yong, P.; Zondervan, K.T.

    2014-01-01

    Objective To harmonize standard operating procedures (SOPs) and standardize the recording of associated data for collection, processing, and storage of human tissues relevant to endometriosis. Design An international collaboration involving 34 clinical/academic centers and three industry collaborators from 16 countries on five continents. Setting In 2013, two workshops were conducted followed by global consultation, bringing together 54 leaders in endometriosis research and sample processing from around the world. Patient(s) None. Intervention(s) Consensus SOPs were based on: 1) systematic comparison of SOPs from 24 global centers collecting tissue samples from women with and without endometriosis on a medium or large scale (publication on >100 cases); 2) literature evidence where available, or consultation with laboratory experts otherwise; and 3) several global consultation rounds. Main Outcome Measure(s) Standard recommended and minimum required SOPs for tissue collection, processing, and storage in endometriosis research. Result(s) We developed “recommended standard” and “minimum required” SOPs for the collection, processing, and storage of ectopic and eutopic endometrium, peritoneum, and myometrium, and a biospecimen data collection form necessary for interpretation of sample-derived results. Conclusion(s) The EPHect SOPs allow endometriosis research centers to decrease variability in tissue-based results, facilitating between-center comparisons and collaborations. The procedures are also relevant to research into other gynecologic conditions involving endometrium, myometrium, and peritoneum. The consensus SOPs are based on the best available evidence; areas with limited evidence are identified as requiring further pilot studies. The SOPs will be reviewed based on investigator feedback and through systematic triannual follow-up. Updated versions will be made available at: http://endometriosisfoundation.org/ephect. PMID:25256928

  9. Performance of Identifiler Direct and PowerPlex 16 HS on the Applied Biosystems 3730 DNA Analyzer for processing biological samples archived on FTA cards.

    PubMed

    Laurin, Nancy; DeMoors, Anick; Frégeau, Chantal

    2012-09-01

    Direct amplification of STR loci from biological samples collected on FTA cards without prior DNA purification was evaluated using Identifiler Direct and PowerPlex 16 HS in conjunction with the use of a high throughput Applied Biosystems 3730 DNA Analyzer. In order to reduce the overall sample processing cost, reduced PCR volumes combined with various FTA disk sizes were tested. Optimized STR profiles were obtained using a 0.53 mm disk size in 10 μL PCR volume for both STR systems. These protocols proved effective in generating high quality profiles on the 3730 DNA Analyzer from both blood and buccal FTA samples. Reproducibility, concordance, robustness, sample stability and profile quality were assessed using a collection of blood and buccal samples on FTA cards from volunteer donors as well as from convicted offenders. The new developed protocols offer enhanced throughput capability and cost effectiveness without compromising the robustness and quality of the STR profiles obtained. These results support the use of these protocols for processing convicted offender samples submitted to the National DNA Data Bank of Canada. Similar protocols could be applied to the processing of casework reference samples or in paternity or family relationship testing. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  10. Antarctic Meteorite Classification and Petrographic Database Enhancements

    NASA Technical Reports Server (NTRS)

    Todd, N. S.; Satterwhite, C. E.; Righter, K.

    2012-01-01

    The Antarctic Meteorite collection, which is comprised of over 18,700 meteorites, is one of the largest collections of meteorites in the world. These meteorites have been collected since the late 1970 s as part of a three-agency agreement between NASA, the National Science Foundation, and the Smithsonian Institution [1]. Samples collected each season are analyzed at NASA s Meteorite Lab and the Smithsonian Institution and results are published twice a year in the Antarctic Meteorite Newsletter, which has been in publication since 1978. Each newsletter lists the samples collected and processed and provides more in-depth details on selected samples of importance to the scientific community. Data about these meteorites is also published on the NASA Curation website [2] and made available through the Meteorite Classification Database allowing scientists to search by a variety of parameters. This paper describes enhancements that have been made to the database and to the data and photo acquisition process to provide the meteorite community with faster access to meteorite data concurrent with the publication of the Antarctic Meteorite Newsletter twice a year.

  11. Standard operating procedures for collection of soil and sediment samples for the Sediment-bound Contaminant Resiliency and Response (SCoRR) strategy pilot study

    USGS Publications Warehouse

    Fisher, Shawn C.; Reilly, Timothy J.; Jones, Daniel K.; Benzel, William M.; Griffin, Dale W.; Loftin, Keith A.; Iwanowicz, Luke R.; Cohl, Jonathan A.

    2015-12-17

    An understanding of the effects on human and ecological health brought by major coastal storms or flooding events is typically limited because of a lack of regionally consistent baseline and trends data in locations proximal to potential contaminant sources and mitigation activities, sensitive ecosystems, and recreational facilities where exposures are probable. In an attempt to close this gap, the U.S. Geological Survey (USGS) has implemented the Sediment-bound Contaminant Resiliency and Response (SCoRR) strategy pilot study to collect regional sediment-quality data prior to and in response to future coastal storms. The standard operating procedure (SOP) detailed in this document serves as the sample-collection protocol for the SCoRR strategy by providing step-by-step instructions for site preparation, sample collection and processing, and shipping of soil and surficial sediment (for example, bed sediment, marsh sediment, or beach material). The objectives of the SCoRR strategy pilot study are (1) to create a baseline of soil-, sand-, marsh sediment-, and bed-sediment-quality data from sites located in the coastal counties from Maine to Virginia based on their potential risk of being contaminated in the event of a major coastal storm or flooding (defined as Resiliency mode); and (2) respond to major coastal storms and flooding by reoccupying select baseline sites and sampling within days of the event (defined as Response mode). For both modes, samples are collected in a consistent manner to minimize bias and maximize quality control by ensuring that all sampling personnel across the region collect, document, and process soil and sediment samples following the procedures outlined in this SOP. Samples are analyzed using four USGS-developed screening methods—inorganic geochemistry, organic geochemistry, pathogens, and biological assays—which are also outlined in this SOP. Because the SCoRR strategy employs a multi-metric approach for sample analyses, this protocol expands upon and reconciles differences in the sample collection protocols outlined in the USGS “National Field Manual for the Collection of Water-Quality Data,” which should be used in conjunction with this SOP. A new data entry and sample tracking system also is presented to ensure all relevant data and metadata are gathered at the sample locations and in the laboratories.

  12. NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE--HUMAN BIOLOGICAL MARKERS:BLOOD AND URINE SAMPLE COLLECTION AND ANALYSES (EOHSI-AP-209-040)

    EPA Science Inventory

    This procedure describes the process for collecting and analyzing blood and urine samples. The presence of chemical contaminants in biological specimens such as blood, urine, and hair represent a measure of the internal dose or body burden for a given individual derived from the ...

  13. Illuminating the NARS data entry black box: what happens between sample collection and data availability for use in assessments?

    EPA Science Inventory

    The steps between field collection of data and samples and availability of the resulting data from National Aquatic Resource Surveys (NARS) can appear to be a black box. This presentation is intended to shed some light on that process. The pathway for data depends on their source...

  14. Biobanking human endometrial tissue and blood specimens: standard operating procedure and importance to reproductive biology research and diagnostic development.

    PubMed

    Sheldon, Elizabeth; Vo, Kim Chi; McIntire, Ramsey A; Aghajanova, Lusine; Zelenko, Zara; Irwin, Juan C; Giudice, Linda C

    2011-05-01

    To develop a standard operating procedure (SOP) for collection, transport, storage of human endometrial tissue and blood samples, subject and specimen annotation, and establishing sample priorities. The SOP synthesizes sound scientific procedures, the literature on ischemia research, sample collection and gene expression profiling, good laboratory practices, and the authors' experience of workflow and sample quality. The National Institutes of Health, University of California, San Francisco, Human Endometrial Tissue and DNA Bank. Women undergoing endometrial biopsy or hysterectomy for nonmalignant indications. Collecting, processing, storing, distributing endometrial tissue and blood samples under approved institutional review board protocols and written informed consent from participating subjects. Standard operating procedure. The SOP addresses rigorous and consistent subject annotation, specimen processing and characterization, strict regulatory compliance, and a reference for researchers to track collection and storage times that may influence their research. The comprehensive and systematic approach to the procurement of human blood and endometrial tissue in this SOP ensures the high quality, reliability, and scientific usefulness of biospecimens made available to investigators by the National Institutes of Health, University of California, San Francisco, Human Endometrial Tissue and DNA Bank. The detail and perspective in this SOP also provides a blueprint for implementation of similar collection programs at other institutions. Copyright © 2011 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  15. Female Reproductive Effects of Exposure to Jet Fuel at U.S. Air Force Bases

    DTIC Science & Technology

    1998-11-01

    volunteers during 1997. Volunteers then provided feedback about the process and made suggestions for improvement. This information was used to develop...breath samples were processed in the field by collecting one (1) liter of expired breath in a Tedlar bag which was subsequently introduced onto a...also alert him when samples were obtained thru to menses. The process for returning samples was also facilitated by the provision of a mailing kit

  16. A review of blood sample handling and pre-processing for metabolomics studies.

    PubMed

    Hernandes, Vinicius Veri; Barbas, Coral; Dudzik, Danuta

    2017-09-01

    Metabolomics has been found to be applicable to a wide range of clinical studies, bringing a new era for improving clinical diagnostics, early disease detection, therapy prediction and treatment efficiency monitoring. A major challenge in metabolomics, particularly untargeted studies, is the extremely diverse and complex nature of biological specimens. Despite great advances in the field there still exist fundamental needs for considering pre-analytical variability that can introduce bias to the subsequent analytical process and decrease the reliability of the results and moreover confound final research outcomes. Many researchers are mainly focused on the instrumental aspects of the biomarker discovery process, and sample related variables sometimes seem to be overlooked. To bridge the gap, critical information and standardized protocols regarding experimental design and sample handling and pre-processing are highly desired. Characterization of a range variation among sample collection methods is necessary to prevent results misinterpretation and to ensure that observed differences are not due to an experimental bias caused by inconsistencies in sample processing. Herein, a systematic discussion of pre-analytical variables affecting metabolomics studies based on blood derived samples is performed. Furthermore, we provide a set of recommendations concerning experimental design, collection, pre-processing procedures and storage conditions as a practical review that can guide and serve for the standardization of protocols and reduction of undesirable variation. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. What can one sample tell us? Stable isotopes can assess complex processes in national assessments of lakes, rivers and streams.

    EPA Science Inventory

    Stable isotopes can be very useful in large-scale monitoring programs because samples for isotopic analysis are easy to collect, and isotopes integrate information about complex processes such as evaporation from water isotopes and denitrification from nitrogen isotopes. Traditi...

  18. 40 CFR 63.1013 - Sampling connection systems standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) National Emission Standards for Equipment Leaks-Control Level 1 § 63.1013 Sampling connection... container are not required to be collected or captured. (c) Equipment design and operation. Each closed... process fluid to a process; or (3) Be designed and operated to capture and transport all the purged...

  19. Process test plan, phase II: waste retrieval sluicing system emissions collection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    POWERS, R.L.

    1999-06-01

    This Process Test Plan is prepared to continue from HNF-3733 which was Phase I of the test. Supplemental operational controls and sampling requirements are defined to safely obtain gas samples from the 296-C-006 ventilation system stack during active operation of the sluicing equipment.

  20. AutoDrug: fully automated macromolecular crystallography workflows for fragment-based drug discovery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, Yingssu; Stanford University, 333 Campus Drive, Mudd Building, Stanford, CA 94305-5080; McPhillips, Scott E.

    New software has been developed for automating the experimental and data-processing stages of fragment-based drug discovery at a macromolecular crystallography beamline. A new workflow-automation framework orchestrates beamline-control and data-analysis software while organizing results from multiple samples. AutoDrug is software based upon the scientific workflow paradigm that integrates the Stanford Synchrotron Radiation Lightsource macromolecular crystallography beamlines and third-party processing software to automate the crystallography steps of the fragment-based drug-discovery process. AutoDrug screens a cassette of fragment-soaked crystals, selects crystals for data collection based on screening results and user-specified criteria and determines optimal data-collection strategies. It then collects and processes diffraction data,more » performs molecular replacement using provided models and detects electron density that is likely to arise from bound fragments. All processes are fully automated, i.e. are performed without user interaction or supervision. Samples can be screened in groups corresponding to particular proteins, crystal forms and/or soaking conditions. A single AutoDrug run is only limited by the capacity of the sample-storage dewar at the beamline: currently 288 samples. AutoDrug was developed in conjunction with RestFlow, a new scientific workflow-automation framework. RestFlow simplifies the design of AutoDrug by managing the flow of data and the organization of results and by orchestrating the execution of computational pipeline steps. It also simplifies the execution and interaction of third-party programs and the beamline-control system. Modeling AutoDrug as a scientific workflow enables multiple variants that meet the requirements of different user groups to be developed and supported. A workflow tailored to mimic the crystallography stages comprising the drug-discovery pipeline of CoCrystal Discovery Inc. has been deployed and successfully demonstrated. This workflow was run once on the same 96 samples that the group had examined manually and the workflow cycled successfully through all of the samples, collected data from the same samples that were selected manually and located the same peaks of unmodeled density in the resulting difference Fourier maps.« less

  1. 14CO2 analysis of soil gas: Evaluation of sample size limits and sampling devices

    NASA Astrophysics Data System (ADS)

    Wotte, Anja; Wischhöfer, Philipp; Wacker, Lukas; Rethemeyer, Janet

    2017-12-01

    Radiocarbon (14C) analysis of CO2 respired from soils or sediments is a valuable tool to identify different carbon sources. The collection and processing of the CO2, however, is challenging and prone to contamination. We thus continuously improve our handling procedures and present a refined method for the collection of even small amounts of CO2 in molecular sieve cartridges (MSCs) for accelerator mass spectrometry 14C analysis. Using a modified vacuum rig and an improved desorption procedure, we were able to increase the CO2 recovery from the MSC (95%) as well as the sample throughput compared to our previous study. By processing series of different sample size, we show that our MSCs can be used for CO2 samples of as small as 50 μg C. The contamination by exogenous carbon determined in these laboratory tests, was less than 2.0 μg C from fossil and less than 3.0 μg C from modern sources. Additionally, we tested two sampling devices for the collection of CO2 samples released from soils or sediments, including a respiration chamber and a depth sampler, which are connected to the MSC. We obtained a very promising, low process blank for the entire CO2 sampling and purification procedure of ∼0.004 F14C (equal to 44,000 yrs BP) and ∼0.003 F14C (equal to 47,000 yrs BP). In contrast to previous studies, we observed no isotopic fractionation towards lighter δ13C values during the passive sampling with the depth samplers.

  2. Contamination of turkey carcasses by thermotolerant species of Campylobacter during postslaughter processing.

    PubMed

    Wysok, B; Uradziński, J

    2009-01-01

    Ample literature data indicate explicitly that the major source of alimentary infections induced by Campylobacter spp. is poultry meat and its products. The undertaken research was aimed at determining the level of contamination of turkey carcasses during selected stages of postslaughter processing. Analyses were conducted on 200 turkey carcasses that were examined in 10 experimental series. In each series, 5 carcasses were analyzed at the selected stages of processing, i.e.: after defeathering, evisceration, washing and chilling. Swabs were collected from each carcass from 20 cm2 skin surface at the area of neck, steak and wall of the body cavity. Out of 550 samples of swabs from the skin surface and wall of the body cavity, 385 isolates were classified as Campylobacter--positive, which constituted 70% of the samples. Out of 100 analyzed swabs collected from the carcasses after defeathering, 73 (73%) were found to contain Campylobacter species. In turn, the presence of this pathogen was confirmed in 122 (81.33%) out of 150 swabs collected from carcasses after evisceration, in 106 (70.66%) swabs collected after washing and in 84 (56%) swabs collected after chilling.

  3. Comparison of Campylobacter contamination levels on chicken carcasses between modern and traditional types of slaughtering facilities in Malaysia.

    PubMed

    Rejab, Saira Banu Mohamed; Zessin, Karl-Hans; Fries, Reinhard; Patchanee, Prapas

    2012-01-01

    A total of 360 samples including fresh fecal droppings, neck skins, and swab samples was collected from 24 broiler flocks and processed by 12 modern processing plants in 6 states in Malaysia. Ninety samples from 10 traditional wet markets located in the same states as modern processing plants were also collected. Microbiological isolation for Campylobacter was performed following ISO 10272-1:2006 (E). The overall rate of contamination for Campylobacter in modern processing plants and in traditional wet markets was 61.1% (220/360) and 85.6% (77/90), respectively. Campylobacter jejuni was detected as the majority with approximately 70% for both facilities. In the modern processing plants, the contamination rate for Campylobacter gradually declined from 80.6% before the inside-outside washing to 62.5% after inside-outside washing and to 38.9% after the post chilling step. The contamination rate for Campylobacter from processed chicken neck skin in traditional wet markets (93.3%) was significantly (P<0.01) higher than in modern processing plants (38.9%).

  4. 7 CFR 52.44 - Inspection fees when charges for sampling have been collected.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946 PROCESSED FRUITS AND VEGETABLES, PROCESSED PRODUCTS THEREOF, AND CERTAIN OTHER PROCESSED FOOD PRODUCTS 1 Regulations Governing Inspection and Certification...

  5. A Synopsis of Technical Issues of Concern for Monitoring Trace Elements in Highway and Urban Runoff

    USGS Publications Warehouse

    Breault, Robert F.; Granato, Gregory E.

    2000-01-01

    Trace elements, which are regulated for aquatic life protection, are a primary concern in highway- and urban-runoff studies because stormwater runoff may transport these constituents from the land surface to receiving waters. Many of these trace elements are essential for biological activity and become detrimental only when geologic or anthropogenic sources exceed concentrations beyond ranges typical of the natural environment. The Federal Highway Administration and State Transportation Agencies are concerned about the potential effects of highway runoff on the watershed scale and for the management and protection of watersheds. Transportation agencies need information that is documented as valid, current, and scientifically defensible to support planning and management decisions. There are many technical issues of concern for monitoring trace elements; therefore, trace-element data commonly are considered suspect, and the responsibility to provide data-quality information to support the validity of reported results rests with the data-collection agency. Paved surfaces are fundamentally different physically, hydraulically, and chemically from the natural surfaces typical of most freshwater systems that have been the focus of many traceelement- monitoring studies. Existing scientific conceptions of the behavior of trace elements in the environment are based largely upon research on natural systems, rather than on systems typical of pavement runoff. Additionally, the logistics of stormwater sampling are difficult because of the great uncertainty in the occurrence and magnitude of storm events. Therefore, trace-element monitoring programs may be enhanced if monitoring and sampling programs are automated. Automation would standardize the process and provide a continuous record of the variations in flow and water-quality characteristics. Great care is required to collect and process samples in a manner that will minimize potential contamination or attenuation of trace elements and other sources of bias and variability in the sampling process. Trace elements have both natural and anthropogenic sources that may affect the sampling process, including the sample-collection and handling materials used in many trace-element monitoring studies. Trace elements also react with these materials within the timescales typical for collection, processing and analysis of runoff samples. To study the characteristics and potential effects of trace elements in highway and urban runoff, investigators typically sample one or more operationally defined matrixes including: whole water, dissolved (filtered water), suspended sediment, bottom sediment, biological tissue, and contaminant sources. The sampling and analysis of each of these sample matrixes can provide specific information about the occurrence and distribution of trace elements in runoff and receiving waters. There are, however, technical concerns specific to each matrix that must be understood and addressed through use of proper collection and processing protocols. Valid protocols are designed to minimize inherent problems and to maximize the accuracy, precision, comparability, and representativeness of data collected. Documentation, including information about monitoring protocols, quality assurance and quality control efforts, and ancillary data also is necessary to establish data quality. This documentation is especially important for evaluation of historical traceelement monitoring data, because trace-element monitoring protocols and analysis methods have been constantly changing over the past 30 years.

  6. Processes in scientific workflows for information seeking related to physical sample materials

    NASA Astrophysics Data System (ADS)

    Ramdeen, S.

    2014-12-01

    The majority of State Geological Surveys have repositories containing cores, cuttings, fossils or other physical sample material. State surveys maintain these collections to support their own research as well as the research conducted by external users from other organizations. This includes organizations such as government agencies (state and federal), academia, industry and the public. The preliminary results presented in this paper will look at the research processes of these external users. In particular: how they discover, access and use digital surrogates, which they use to evaluate and access physical items in these collections. Data such as physical samples are materials that cannot be completely replaced with digital surrogates. Digital surrogates may be represented as metadata, which enable discovery and ultimately access to these samples. These surrogates may be found in records, databases, publications, etc. But surrogates do not completely prevent the need for access to the physical item as they cannot be subjected to chemical testing and/or other similar analysis. The goal of this research is to document the various processes external users perform in order to access physical materials. Data for this study will be collected by conducting interviews with these external users. During the interviews, participants will be asked to describe the workflow that lead them to interact with state survey repositories, and what steps they took afterward. High level processes/categories of behavior will be identified. These processes will be used in the development of an information seeking behavior model. This model may be used to facilitate the development of management tools and other aspects of cyberinfrastructure related to physical samples.

  7. EPA Tools and Resources Webinar: EPA’s Environmental Sampling and Analytical Methods for Environmental Remediation and Recovery

    EPA Pesticide Factsheets

    EPA’s Environmental Sampling and Analytical Methods (ESAM) is a website tool that supports the entire environmental characterization process from collection of samples all the way to their analyses.

  8. Conducting On-orbit Gene Expression Analysis on ISS: WetLab-2

    NASA Technical Reports Server (NTRS)

    Parra, Macarena; Almeida, Eduardo; Boone, Travis; Jung, Jimmy; Lera, Matthew P.; Ricco, Antonio; Souza, Kenneth; Wu, Diana; Richey, C. Scott

    2013-01-01

    WetLab-2 will enable expanded genomic research on orbit by developing tools that support in situ sample collection, processing, and analysis on ISS. This capability will reduce the time-to-results for investigators and define new pathways for discovery on the ISS National Lab. The primary objective is to develop a research platform on ISS that will facilitate real-time quantitative gene expression analysis of biological samples collected on orbit. WetLab-2 will be capable of processing multiple sample types ranging from microbial cultures to animal tissues dissected on orbit. WetLab-2 will significantly expand the analytical capabilities onboard ISS and enhance science return from ISS.

  9. Process and apparatus for obtaining samples of liquid and gas from soil

    DOEpatents

    Rossabi, J.; May, C.P.; Pemberton, B.E.; Shinn, J.; Sprague, K.

    1999-03-30

    An apparatus and process for obtaining samples of liquid and gas from subsurface soil is provided having filter zone adjacent an external expander ring. The expander ring creates a void within the soil substrate which encourages the accumulation of soil-borne fluids. The fluids migrate along a pressure gradient through a plurality of filters before entering a first chamber. A one-way valve regulates the flow of fluid into a second chamber in further communication with a collection tube through which samples are collected at the surface. A second one-way valve having a reverse flow provides additional communication between the chambers for the pressurized cleaning and back-flushing of the apparatus. 8 figs.

  10. Process and apparatus for obtaining samples of liquid and gas from soil

    DOEpatents

    Rossabi, Joseph; May, Christopher P.; Pemberton, Bradley E.; Shinn, Jim; Sprague, Keith

    1999-01-01

    An apparatus and process for obtaining samples of liquid and gas from subsurface soil is provided having filter zone adjacent an external expander ring. The expander ring creates a void within the soil substrate which encourages the accumulation of soil-borne fluids. The fluids migrate along a pressure gradient through a plurality of filters before entering a first chamber. A one-way valve regulates the flow of fluid into a second chamber in further communication with a collection tube through which samples are collected at the surface. A second one-way valve having a reverse flow provides additional communication between the chambers for the pressurized cleaning and back-flushing of the apparatus.

  11. Optimizing Urine Processing Protocols for Protein and Metabolite Detection.

    PubMed

    Siddiqui, Nazema Y; DuBois, Laura G; St John-Williams, Lisa; Will, Thompson J; Grenier, Carole; Burke, Emily; Fraser, Matthew O; Amundsen, Cindy L; Murphy, Susan K

    In urine, factors such as timing of voids, and duration at room temperature (RT) may affect the quality of recovered protein and metabolite data. Additives may aid with detection, but can add more complexity in sample collection or analysis. We aimed to identify the optimal urine processing protocol for clinically-obtained urine samples that allows for the highest protein and metabolite yields with minimal degradation. Healthy women provided multiple urine samples during the same day. Women collected their first morning (1 st AM) void and another "random void". Random voids were aliquotted with: 1) no additive; 2) boric acid (BA); 3) protease inhibitor (PI); or 4) both BA + PI. Of these aliquots, some were immediately stored at 4°C, and some were left at RT for 4 hours. Proteins and individual metabolites were quantified, normalized to creatinine concentrations, and compared across processing conditions. Sample pools corresponding to each processing condition were analyzed using mass spectrometry to assess protein degradation. Ten Caucasian women between 35-65 years of age provided paired 1 st morning and random voided urine samples. Normalized protein concentrations were slightly higher in 1 st AM compared to random "spot" voids. The addition of BA did not significantly change proteins, while PI significantly improved normalized protein concentrations, regardless of whether samples were immediately cooled or left at RT for 4 hours. In pooled samples, there were minimal differences in protein degradation under the various conditions we tested. In metabolite analyses, there were significant differences in individual amino acids based on the timing of the void. For comparative translational research using urine, information about void timing should be collected and standardized. For urine samples processed in the same day, BA does not appear to be necessary while the addition of PI enhances protein yields, regardless of 4°C or RT storage temperature.

  12. Molecular comparison of the sampling efficiency of four types of airborne bacterial samplers.

    PubMed

    Li, Kejun

    2011-11-15

    In the present study, indoor and outdoor air samples were collected using four types of air samplers often used for airborne bacterial sampling. These air samplers included two solid impactors (BioStage and RCS), one liquid impinger (BioSampler), and one filter sampler with two kinds of filters (a gelatin and a cellulose acetate filter). The collected air samples were further processed to analyze the diversity and abundance of culturable bacteria and total bacteria through standard culture techniques, denaturing gradient gel electrophoresis (DGGE) fingerprinting and quantitative polymerase chain reaction (qPCR) analysis. The DGGE analysis indicated that the air samples collected using the BioStage and RCS samplers have higher culturable bacterial diversity, whereas the samples collected using the BioSampler and the cellulose acetate filter sampler have higher total bacterial diversity. To obtain more information on the sampled bacteria, some gel bands were excised and sequenced. In terms of sampling efficiency, results from the qPCR tests indicated that the collected total bacterial concentration was higher in samples collected using the BioSampler and the cellulose acetate filter sampler. In conclusion, the sampling bias and efficiency of four kinds of air sampling systems were compared in the present study and the two solid impactors were concluded to be comparatively efficient for culturable bacterial sampling, whereas the liquid impactor and the cellulose acetate filter sampler were efficient for total bacterial sampling. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Combining Laser Ablation/Liquid Phase Collection Surface Sampling and High-Performance Liquid Chromatography Electrospray Ionization Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ovchinnikova, Olga S; Kertesz, Vilmos; Van Berkel, Gary J

    This paper describes the coupling of ambient pressure transmission geometry laser ablation with a liquid phase sample collection method for surface sampling and ionization with subsequent mass spectral analysis. A commercially available autosampler was adapted to produce a liquid droplet at the end of the syringe injection needle while in close proximity to the surface to collect the sample plume produced by laser ablation. The sample collection was followed by either flow injection or a high performance liquid chromatography (HPLC) separation of the extracted components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the analytical utility of thismore » coupling, thin films of a commercial ink sample containing rhodamine 6G and of mixed isobaric rhodamine B and 6G dyes on glass microscope slides were analyzed. The flow injection and HPLC/ESI-MS analysis revealed successful laser ablation, capture and, with HPLC, the separation of the two compounds. The ablated circular area was about 70 m in diameter for these experiments. The spatial sampling resolution afforded by the laser ablation, as well as the ability to use sample processing methods like HPLC between the sample collection and ionization steps, makes this combined surface sampling/ionization technique a highly versatile analytical tool.« less

  14. 7 CFR 52.45 - Inspection fees when charges for sampling have not been collected.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946 PROCESSED FRUITS AND VEGETABLES, PROCESSED PRODUCTS THEREOF, AND CERTAIN OTHER PROCESSED FOOD PRODUCTS 1 Regulations Governing Inspection and...

  15. Development and evaluation of a multiple-plate fraction collector for sample processing: application to radioprofiling in drug metabolism studies.

    PubMed

    Barros, Anthony; Ly, Van T; Chando, Theodore J; Ruan, Qian; Donenfeld, Scott L; Holub, David P; Christopher, Lisa J

    2011-04-05

    Microplate scintillation counters are utilized routinely in drug metabolism laboratories for the off-line radioanalysis of fractions collected during HPLC radioprofiling. In this process, the current fraction collection technology is limited by the number of plates that can be used per injection as well as the potential for sample loss due to dripping or spraying as the fraction collector head moves from well to well or between plates. More importantly, sample throughput is limited in the conventional process, since the collection plates must be manually exchanged after each injection. The Collect PAL, an innovative multiple-plate fraction collector, was developed to address these deficiencies and improve overall sample throughput. It employs a zero-loss design and has sub-ambient temperature control. Operation of the system is completely controlled with software and up to 24 (96- or 384-well) fraction collection plates can be loaded in a completely automated run. The system may also be configured for collection into various-sized tubes or vials. At flow rates of 0.5 or 1.0 mL/min and at collection times of 10 or 15s, the system precisely delivered 83-μL fractions (within 4.1% CV) and 250-μL fractions (within 1.4% CV), respectively, of three different mobile phases into 12 mm × 32 mm vials. Similarly, at a flow rate of 1 mL/min and 10s collection times, the system precisely dispensed mobile phase containing a [(14)C]-radiolabeled compound across an entire 96-well plate (% CV was within 5.3%). Triplicate analyses of metabolism test samples containing [(14)C]buspirone and its metabolites, derived from three different matrices (plasma, urine and bile), indicated that the Collect PAL produced radioprofiles that were reproducible and comparable to the current technology; the % CV for 9 selected peaks in the radioprofiles generated with the Collect PAL were within 9.3%. Radioprofiles generated by collecting into 96- and 384-well plates were qualitatively comparable; however, the peak resolution was greater in the profiles that were collected in 384-well plates due to the collection of a larger number of fractions per minute. In conclusion, this new and innovative fraction collector generated radioprofile results that were comparable to current technology and should provide a major improvement in capacity and throughput for radioprofiling studies. Copyright © 2010 Elsevier B.V. All rights reserved.

  16. Kuipers performs Water Sample Analysis

    NASA Image and Video Library

    2012-05-15

    ISS031-E-084619 (15 May 2012) --- After collecting samples from the Water Recovery System (WRS), European Space Agency astronaut Andre Kuipers, Expedition 31 flight engineer, processes the samples for chemical and microbial analysis in the Unity node of the International Space Station.

  17. RoboDiff: combining a sample changer and goniometer for highly automated macromolecular crystallography experiments

    PubMed Central

    Nurizzo, Didier; Bowler, Matthew W.; Caserotto, Hugo; Dobias, Fabien; Giraud, Thierry; Surr, John; Guichard, Nicolas; Papp, Gergely; Guijarro, Matias; Mueller-Dieckmann, Christoph; Flot, David; McSweeney, Sean; Cipriani, Florent; Theveneau, Pascal; Leonard, Gordon A.

    2016-01-01

    Automation of the mounting of cryocooled samples is now a feature of the majority of beamlines dedicated to macromolecular crystallography (MX). Robotic sample changers have been developed over many years, with the latest designs increasing capacity, reliability and speed. Here, the development of a new sample changer deployed at the ESRF beamline MASSIF-1 (ID30A-1), based on an industrial six-axis robot, is described. The device, named RoboDiff, includes a high-capacity dewar, acts as both a sample changer and a high-accuracy goniometer, and has been designed for completely unattended sample mounting and diffraction data collection. This aim has been achieved using a high level of diagnostics at all steps of the process from mounting and characterization to data collection. The RoboDiff has been in service on the fully automated endstation MASSIF-1 at the ESRF since September 2014 and, at the time of writing, has processed more than 20 000 samples completely automatically. PMID:27487827

  18. IDATEN and G-SITENNO: GUI-assisted software for coherent X-ray diffraction imaging experiments and data analyses at SACLA.

    PubMed

    Sekiguchi, Yuki; Yamamoto, Masaki; Oroguchi, Tomotaka; Takayama, Yuki; Suzuki, Shigeyuki; Nakasako, Masayoshi

    2014-11-01

    Using our custom-made diffraction apparatus KOTOBUKI-1 and two multiport CCD detectors, cryogenic coherent X-ray diffraction imaging experiments have been undertaken at the SPring-8 Angstrom Compact free electron LAser (SACLA) facility. To efficiently perform experiments and data processing, two software suites with user-friendly graphical user interfaces have been developed. The first is a program suite named IDATEN, which was developed to easily conduct four procedures during experiments: aligning KOTOBUKI-1, loading a flash-cooled sample into the cryogenic goniometer stage inside the vacuum chamber of KOTOBUKI-1, adjusting the sample position with respect to the X-ray beam using a pair of telescopes, and collecting diffraction data by raster scanning the sample with X-ray pulses. Named G-SITENNO, the other suite is an automated version of the original SITENNO suite, which was designed for processing diffraction data. These user-friendly software suites are now indispensable for collecting a large number of diffraction patterns and for processing the diffraction patterns immediately after collecting data within a limited beam time.

  19. Composition and Morphology of Major Particle Types from Airborne Measurements during ICE-T and PRADACS Field Studies

    NASA Astrophysics Data System (ADS)

    Venero, I. M.; Mayol-Bracero, O. L.; Anderson, J. R.

    2012-12-01

    As part of the Puerto Rican African Dust and Cloud Study (PRADACS) and the Ice in Clouds Experiment - Tropical (ICE-T), we sampled giant airborne particles to study their elemental composition, morphology, and size distributions. Samples were collected in July 2011 during field measurements performed by NCAR's C-130 aircraft based on St Croix, U.S Virgin Island. The results presented here correspond to the measurements done during research flight #8 (RF8). Aerosol particles with Dp > 1 um were sampled with the Giant Nuclei Impactor and particles with Dp < 1 um were collected with the Wyoming Inlet. Collected particles were later analyzed using an automated scanning electron microscope (SEM) and manual observation by field emission SEM. We identified the chemical composition and morphology of major particle types in filter samples collected at different altitudes (e.g., 300 ft, 1000 ft, and 4500ft). Results from the flight upwind of Puerto Rico show that particles in the giant nuclei size range are dominated by sea salt. Samples collected at altitudes 300 ft and 1000 ft showed the highest number of sea salt particles and the samples collected at higher altitudes (> 4000 ft) showed the highest concentrations of clay material. HYSPLIT back trajectories for all samples showed that the low altitude samples initiated in the free troposphere in the Atlantic Ocean, which may account for the high sea salt content and that the source of the high altitude samples was closer to the Saharan - Sahel desert region and, therefore, these samples possibly had the influence of African dust. Size distribution results for quartz and unreacted sea-salt aerosols collected on the Giant Nuclei Impactor showed that sample RF08 - 12:05 UTM (300 ft) had the largest size value (mean = 2.936 μm) than all the other samples. Additional information was also obtained from the Wyoming Inlet present at the C - 130 aircraft which showed that size distribution results for all particles were smaller in size. The different mineral components of the dust have different size distributions so that a fractionation process could occur during transport. Also, the presence of supermicron sea salt at altitude is important for cloud processes.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyrrell, Evan; Denny, Angelita

    Fifty-two groundwater samples and one surface water sample were collected at the Monument Valley, Arizona, Processing Site to monitor groundwater contaminants for evaluating the effectiveness of the proposed compliance strategy as specified in the 1999 Final Site Observational Work Plan for the UMTRA Project Site at Monument Valley, Arizona. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and-analysis-plan-us-department- energy-office-legacy-management-sites). Samples were collected for metals, anions, nitrate + nitrite as N, and ammonia as N analyses at all locations.

  1. Microwave Processing for Sample Preparation to Evaluate Mitochondrial Ultrastructural Damage in Hemorrhagic Shock

    NASA Astrophysics Data System (ADS)

    Josephsen, Gary D.; Josephsen, Kelly A.; Beilman, Greg J.; Taylor, Jodie H.; Muiler, Kristine E.

    2005-12-01

    This is a report of the adaptation of microwave processing in the preparation of liver biopsies for transmission electron microscopy (TEM) to examine ultrastructural damage of mitochondria in the setting of metabolic stress. Hemorrhagic shock was induced in pigs via 35% total blood volume bleed and a 90-min period of shock followed by resuscitation. Hepatic biopsies were collected before shock and after resuscitation. Following collection, biopsies were processed for TEM by a rapid method involving microwave irradiation (Giberson, 2001). Samples pre- and postshock of each of two animals were viewed and scored using the mitochondrial ultrastructure scoring system (Crouser et al., 2002), a system used to quantify the severity of ultrastructural damage during shock. Results showed evidence of increased ultrastructural damage in the postshock samples, which scored 4.00 and 3.42, versus their preshock controls, which scored 1.18 and 1.27. The results of this analysis were similar to those obtained in another model of shock (Crouser et al., 2002). However, the amount of time used to process the samples was significantly shortened with methods involving microwave irradiation.

  2. Operational Procedures for Collecting Water-Quality Samples at Monitoring Sites on Maple Creek Near Nickerson and the Platte River at Louisville, Eastern Nebraska

    USGS Publications Warehouse

    Johnson, Steven M.; Swanson, Robert B.

    1994-01-01

    Prototype stream-monitoring sites were operated during part of 1992 in the Central Nebraska Basins (CNBR) and three other study areas of the National Water-Quality Assessment (NAWQ) Program of the U.S. Geological Survey. Results from the prototype project provide information needed to operate a net- work of intensive fixed station stream-monitoring sites. This report evaluates operating procedures for two NAWQA prototype sites at Maple Creek near Nickerson and the Platte River at Louisville, eastern Nebraska. Each site was sampled intensively in the spring and late summer 1992, with less intensive sampling in midsummer. In addition, multiple samples were collected during two high- flow periods at the Maple Creek site--one early and the other late in the growing season. Water-samples analyses included determination of pesticides, nutrients, major ions, suspended sediment, and measurements of physical properties. Equipment and protocols for the water-quality sampling procedures were evaluated. Operation of the prototype stream- monitoring sites included development and comparison of onsite and laboratory sample-processing proce- dures. Onsite processing was labor intensive but allowed for immediate preservation of all sampled constituents. Laboratory processing required less field labor and decreased the risk of contamination, but allowed for no immediate preservation of the samples.

  3. Quality of wet deposition in the Grand Calumet River watershed, northwestern Indiana, October 17, 1995-November 12, 1996

    USGS Publications Warehouse

    Willoughby, Timothy C.

    2000-01-01

    In June 1992, a wet-deposition collection site was established at the Gary (Indiana) Regional Airport to monitor the quantity and chemical quality of wet deposition. During the first phase of sampling, 48 wet-deposition samples were collected between June 30, 1992, and August 31, 1993. A second phase of sampling began in October 1995. During the second phase of sampling, 40 wet-deposition samples were collected between October 17, 1995, and November 12, 1996. This report presents the findings for the second phase of sampling and compares those results to the first phase of sampling. Northwestern Indiana is a heavily industrialized area. Steel production and petroleum refining are two of the area?s predominant industries. High-temperature processes, such as fossil-fuel combustion and steel production, release contaminants to the atmosphere that may result in wet deposition being a major contributor to major-ion and trace-metal loadings in northwestern Indiana and Lake Michigan. Wet-deposition samples collected during the first and second phases of sampling were analyzed for pH, specific conductance, and selected major ions and trace metals. Forty weekly wet-deposition samples were collected at the Gary (Indiana) Regional Airport during the second phase of sampling. Approximately 1.2 times as much wet deposition was collected during the second phase of sampling compared to the first phase. Statistically significant increases (at the 5-percent significance level) in concentrations of potassium, iron, lead, and zinc were determined for samples collected during the second phase of sampling when compared to the first. No statistically significant differences were determined in constituent concentrations between samples collected during warm weather (April 1 through October 31) and during cold weather (November 1 through March 31). Annual loadings for the second phase of sampling were greater than 2 times the loadings determined during the first phase of sampling for silica, iron, potassium, lead, and zinc.

  4. Detection of Poliovirus Circulation by Environmental Surveillance in the Absence of Clinical Cases in Israel and the Palestinian Authority

    PubMed Central

    Manor, Y.; Handsher, R.; Halmut, T.; Neuman, M.; Bobrov, A.; Rudich, H.; Vonsover, A.; Shulman, L.; Kew, O.; Mendelson, E.

    1999-01-01

    The global eradication of poliomyelitis, believed to be achievable around the year 2000, relies on strategies which include high routine immunization coverage and mass vaccination campaigns, along with continuous monitoring of wild-type virus circulation by using the laboratory-based acute flaccid paralysis (AFP) surveillance. Israel and the Palestinian Authority are located in a geographical region in which poliovirus is still endemic but have been free of poliomyelitis since 1988 as a result of intensive immunization programs and mass vaccination campaigns. To monitor the wild-type virus circulation, environmental surveillance of sewage samples collected monthly from 25 to 30 sites across the country was implemented in 1989 and AFP surveillance began in 1994. The sewage samples were processed in the laboratory with a double-selective tissue culture system, which enabled economical processing of large number of samples. Between 1989 and 1997, 2,294 samples were processed, and wild-type poliovirus was isolated from 17 of them in four clusters, termed “silent outbreaks,” in September 1990 (type 3), between May and September 1991 (type 1), between October 1994 and June 1995 (type 1), and in December 1996 (type 1). Fifteen of the 17 positive samples were collected in the Gaza Strip, 1 was collected in the West Bank, and 1 was collected in the Israeli city of Ashdod, located close to the Gaza Strip. The AFP surveillance system failed to detect the circulating wild-type viruses. These findings further emphasize the important role that environmental surveillance can play in monitoring the eradication of polioviruses. PMID:10325305

  5. Changes in the microbial communities during co-composting of digestates☆

    PubMed Central

    Franke-Whittle, Ingrid H.; Confalonieri, Alberto; Insam, Heribert; Schlegelmilch, Mirko; Körner, Ina

    2014-01-01

    Anaerobic digestion is a waste treatment method which is of increasing interest worldwide. At the end of the process, a digestate remains, which can gain added value by being composted. A study was conducted in order to investigate microbial community dynamics during the composting process of a mixture of anaerobic digestate (derived from the anaerobic digestion of municipal food waste), green wastes and a screened compost (green waste/kitchen waste compost), using the COMPOCHIP microarray. The composting process showed a typical temperature development, and the highest degradation rates occurred during the first 14 days of composting, as seen from the elevated CO2 content in the exhaust air. With an exception of elevated nitrite and nitrate levels in the day 34 samples, physical–chemical parameters for all compost samples collected during the 63 day process indicated typical composting conditions. The microbial communities changed over the 63 days of composting. According to principal component analysis of the COMPOCHIP microarray results, compost samples from the start of the experiment were found to cluster most closely with the digestate and screened compost samples. The green waste samples were found to group separately. All starting materials investigated were found to yield fewer and lower signals when compared to the samples collected during the composting experiment. PMID:24456768

  6. Extraterrestrial Materials: The Role of Synchrotron Radiation Analyses in the Study of Our Solar System

    ScienceCinema

    Sutton, Stephen R. [University of Chicago, Chicago, Illinois, United States

    2017-12-09

    Sample-return missions and natural collection processes have provided us with a surprisingly extensive collection of matter from Solar System bodies other than the Earth. These collections include samples from the Moon, Mars, asteroids, interplanetary dust, and, recently, from the Sun (solar wind) and a comet. This presentation will describe some of these materials, how they were collected, and what we have learned from them. Synchrotron radiation analyses of these materials are playing an increasingly valuable role in unraveling the histories and properities of the parent Solar System bodies.

  7. Disposable collection kit for rapid and reliable collection of saliva.

    PubMed

    Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek

    2015-01-01

    To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 μl) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method on subsequent immunoassay results was verified by assessing salivary cortisol levels in the samples and comparing them to controls. The recovered volumes for the whole saliva samples were 3.85 ± 0.28, 10.79 ± 0.95, and 31.18 ± 1.72 μl, respectively (CV = 8.76%) and 2.91 ± 0.19, 9.75 ± 0.43, and 29.64 ± 0.91 μl, respectively, (CV = 6.36%) for the controls. There was a close correspondence between the salivary cortisol levels from the saliva samples obtained by the collection kit and the controls (R(2)  > 0.96). The disposable saliva collection kit allows accurate and repeatable collection of fixed amounts of whole saliva and does not interfere with subsequent measurements of salivary cortisol. The simple collection process, lack of elaborate specimen recovery steps, and the short turnaround time (<3 min) should render the kit attractive to test subjects and researchers alike. © 2015 Wiley Periodicals, Inc.

  8. Groundwater environmental tracer data collected from the Chicot, Evangeline, and Jasper aquifers in Montgomery County and adjacent counties, Texas, 2008

    USGS Publications Warehouse

    Oden, Timothy D.

    2011-01-01

    The Gulf Coast aquifer system is the primary water supply for Montgomery County in southeastern Texas, including part of the Houston metropolitan area and the cities of Magnolia, Conroe, and The Woodlands Township, Texas. The U.S. Geological Survey, in cooperation with the Lone Star Groundwater Conservation District, collected environmental tracer data in the Gulf Coast aquifer system, primarily in Montgomery County. Forty existing groundwater wells screened in the Gulf Coast aquifer system were selected for sampling in Montgomery County (38 wells), Waller County (1 well), and Walker County (1 well). Groundwater-quality samples, physicochemical properties, and water-level data were collected once from each of the 40 wells during March-September 2008. Groundwater-quality samples were analyzed for dissolved gases and the environmental tracers sulfur hexafluoride, chlorofluorocarbons, tritium, helium-4, and helium-3/tritium. Water samples were collected and processed onsite using methods designed to minimize changes to the water-sample chemistry or contamination from the atmosphere. Replicate samples for quality assurance and quality control were collected with each environmental sample. Well-construction information and environmental tracer data for March-September 2008 are presented.

  9. Physical Validation of TRMM TMI and PR Monthly Rain Products Over Oklahoma

    NASA Technical Reports Server (NTRS)

    Fisher, Brad L.

    2004-01-01

    The Tropical Rainfall Measuring Mission (TRMM) provides monthly rainfall estimates using data collected by the TRMM satellite. These estimates cover a substantial fraction of the earth's surface. The physical validation of TRMM estimates involves corroborating the accuracy of spaceborne estimates of areal rainfall by inferring errors and biases from ground-based rain estimates. The TRMM error budget consists of two major sources of error: retrieval and sampling. Sampling errors are intrinsic to the process of estimating monthly rainfall and occur because the satellite extrapolates monthly rainfall from a small subset of measurements collected only during satellite overpasses. Retrieval errors, on the other hand, are related to the process of collecting measurements while the satellite is overhead. One of the big challenges confronting the TRMM validation effort is how to best estimate these two main components of the TRMM error budget, which are not easily decoupled. This four-year study computed bulk sampling and retrieval errors for the TRMM microwave imager (TMI) and the precipitation radar (PR) by applying a technique that sub-samples gauge data at TRMM overpass times. Gridded monthly rain estimates are then computed from the monthly bulk statistics of the collected samples, providing a sensor-dependent gauge rain estimate that is assumed to include a TRMM equivalent sampling error. The sub-sampled gauge rain estimates are then used in conjunction with the monthly satellite and gauge (without sub- sampling) estimates to decouple retrieval and sampling errors. The computed mean sampling errors for the TMI and PR were 5.9% and 7.796, respectively, in good agreement with theoretical predictions. The PR year-to-year retrieval biases exceeded corresponding TMI biases, but it was found that these differences were partially due to negative TMI biases during cold months and positive TMI biases during warm months.

  10. Environmental Sampling & Analytical Methods (ESAM) Program - Home

    EPA Pesticide Factsheets

    ESAM is a comprehensive program to facilitate a coordinated response to a chemical, radiochemical, biotoxin or pathogen contamination incident focusing on sample collection, processing, and analysis to provide quality results to the field.

  11. Martian Analogue Sample Characterization and Spectral Library Development at the Johnson Space Center

    NASA Technical Reports Server (NTRS)

    Morris, Richard V.

    2002-01-01

    An extensive collection of Martian analogue samples housed at the Johnson Space Center is the focus of ongoing research by the JSC Mars soil genesis group and their collaborators. Because the major element composition of Martian meteorites and in situ analyses of Martian soils and rocks indicate that Mars is predominantly an iron-rich basaltic world, the focus of active sample collection and analysis is basaltic materials and their hydrolytic (both aqueous and hydrothermal) and sulfatetic alteration products. Described below are the scope of the JSC Mars analogue sample collection, the characterization process, and plans to incorporate the data into spectral libraries for the Mars 2003 Mars Exploration Rover (MER) and Mars 2005 Mars Reconnaissance Orbiter (MRO) CRISM missions.

  12. Advanced Curation Activities at NASA: Preparing to Receive, Process, and Distribute Samples Returned from Future Missions

    NASA Technical Reports Server (NTRS)

    McCubbin, Francis M.; Zeigler, Ryan A.

    2017-01-01

    The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10F JSC is charged with curation of all extraterrestrial material under NASA control, including future NASA missions. The Directive goes on to define Curation as including documentation, preservation, preparation, and distribution of samples for research, education, and public outreach. Here we briefly describe NASA's astromaterials collections and our ongoing efforts related to enhancing the utility of our current collections as well as our efforts to prepare for future sample return missions. We collectively refer to these efforts as advanced curation.

  13. Consent process for US-based family reference DNA samples.

    PubMed

    Katsanis, Sara H; Snyder, Lindsey; Arnholt, Kelly; Mundorff, Amy Z

    2018-01-01

    DNA collection from family members of the missing is a tenet for missing persons' and mass fatality investigations. Procedures for consenting family members are disparate, depending on the context supporting the reason for sample collection. While guidelines and best practices have been developed for handling mass fatalities and for identification of the missing, these guidelines do not address standard consent practices for living family members of potential victims. We examined the relevant U.S. laws, international guidelines and best practices, sampled consent forms currently used for DNA collection of family members, and drafted model language for a consent form to communicate the required and recommended information. We modeled the consent form on biobank consenting practices and tested the consent language among students and the general population for constructive feedback and readability. We also asked respondents to consider the options for DNA collection and either hypothetically agree or disagree. The model language presented here highlights information important to relay in consent processes and can serve as a foundation for future consent practices in mass fatalities and missing persons' investigations. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Antarctic Meteorite Classification and Petrographic Database

    NASA Technical Reports Server (NTRS)

    Todd, Nancy S.; Satterwhite, C. E.; Righter, Kevin

    2011-01-01

    The Antarctic Meteorite collection, which is comprised of over 18,700 meteorites, is one of the largest collections of meteorites in the world. These meteorites have been collected since the late 1970's as part of a three-agency agreement between NASA, the National Science Foundation, and the Smithsonian Institution [1]. Samples collected each season are analyzed at NASA s Meteorite Lab and the Smithsonian Institution and results are published twice a year in the Antarctic Meteorite Newsletter, which has been in publication since 1978. Each newsletter lists the samples collected and processed and provides more in-depth details on selected samples of importance to the scientific community. Data about these meteorites is also published on the NASA Curation website [2] and made available through the Meteorite Classification Database allowing scientists to search by a variety of parameters

  15. Impact of collection container material and holding times on sample integrity for mercury and methylmercury in water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riscassi, Ami L; Miller, Carrie L; Brooks, Scott C

    Mercury (Hg) and methylmercury (MeHg) concentrations in streamwater can vary on short timescales (hourly or less) during storm flow and on a diel cycle; the frequency and timing of sampling required to accurately characterize these dynamics may be difficult to accomplish manually. Automated sampling can assist in sample collection; however use has been limited for Hg and MeHg analysis due to stability concerns of trace concentrations during extended storage times. We examined the viability of using automated samplers with disposable low-density polyethylene (LDPE) sample bags to collect industrially contaminated streamwater for unfiltered and filtered Hg and MeHg analysis. Specifically wemore » investigated the effect of holding times ranging from hours to days on streamwater collected during baseflow and storm flow. Unfiltered and filtered Hg and MeHg concentrations decreased with increases in time prior to sample processing; holding times of 24 hours or less resulted in concentration changes (mean 11 7% different) similar to variability in duplicates collected manually during analogous field conditions (mean 7 10% different). Comparisons of samples collected with manual and automated techniques throughout a year for a wide range of stream conditions were also found to be similar to differences observed between duplicate grab samples. These results demonstrate automated sampling into LDPE bags with holding times of 24 hours or less can be effectively used to collect streamwater for Hg and MeHg analysis, and encourage the testing of these materials and methods for implementation in other aqueous systems where high-frequency sampling is warranted.« less

  16. Effects of the number of people on efficient capture and sample collection: a lion case study.

    PubMed

    Ferreira, Sam M; Maruping, Nkabeng T; Schoultz, Darius; Smit, Travis R

    2013-05-24

    Certain carnivore research projects and approaches depend on successful capture of individuals of interest. The number of people present at a capture site may determine success of a capture. In this study 36 lion capture cases in the Kruger National Park were used to evaluate whether the number of people present at a capture site influenced lion response rates and whether the number of people at a sampling site influenced the time it took to process the collected samples. The analyses suggest that when nine or fewer people were present, lions appeared faster at a call-up locality compared with when there were more than nine people. The number of people, however, did not influence the time it took to process the lions. It is proposed that efficient lion capturing should spatially separate capture and processing sites and minimise the number of people at a capture site.

  17. High throughput DNA damage quantification of human tissue with home-based collection device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Costes, Sylvain V.; Tang, Jonathan; Yannone, Steven M.

    Kits, methods and systems for providing a service to provide a subject with information regarding the state of a subject's DNA damage. Collection, processing and analysis of samples are also described.

  18. The Problem of Sample Contamination in a Fluvial Geochemistry Research Experience for Undergraduates.

    ERIC Educational Resources Information Center

    Andersen, Charles B.

    2001-01-01

    Introduces the analysis of a river as an excellent way to teach geochemical techniques because of the relative ease of sample collection and speed of sample analysis. Focuses on the potential sources of sample contamination during sampling, filtering, and bottle cleaning processes, and reviews methods to reduce and detect contamination. Includes…

  19. Prevalence Rates of Escherichia coli O157:H7 and Salmonella at Different Sampling Sites on Cattle Hides at a Feedlot and Processing Plant

    USDA-ARS?s Scientific Manuscript database

    The distributions of Escherichia coli O157:H7 and Salmonella on cattle hides were mapped at a feedlot and a processing plant. Sponge samples were collected from six hide surface sites at the feedlot (left and right shoulders, left and right ribs, back, and belly) and four sites at the processing pla...

  20. Mutagen Sensitivity, Apoptosis, and Polymorphism in DNA Repair as Measures of Prostate Cancer Risk

    DTIC Science & Technology

    2005-02-01

    blood tubes are immediately refrigerated and delivered on ice within 6 hours to the GCRC core facility at Georgetown University for processing . Case...is CLIA certified. There is a centrally monitored storage facility with -80’C freezers. The established recruitment and optimized sample processing in...controls. We have established the recruitment procedures, sample collection, processing , repository, and data management. This is a substantial effort

  1. Improved explosive collection and detection with rationally assembled surface sampling materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chouyyok, Wilaiwan; Bays, J. Timothy; Gerasimenko, Aleksandr A.

    Sampling and detection of trace explosives is a key analytical process in modern transportation safety. In this work we have explored some of the fundamental analytical processes for collection and detection of trace level explosive on surfaces with the most widely utilized system, thermal desorption IMS. The performance of the standard muslin swipe material was compared with chemically modified fiberglass cloth. The fiberglass surface was modified to include phenyl functional groups. When compared to standard muslin, the phenyl functionalized fiberglass sampling material showed better analyte release from the sampling material as well as improved response and repeatability from multiple usesmore » of the same swipe. The improved sample release of the functionalized fiberglass swipes resulted in a significant increase in sensitivity. Various physical and chemical properties were systematically explored to determine optimal performance. The results herein have relevance to improving the detection of other explosive compounds and potentially to a wide range of other chemical sampling and field detection challenges.« less

  2. Pre-analytical effects of blood sampling and handling in quantitative immunoassays for rheumatoid arthritis.

    PubMed

    Zhao, Xiaoyan; Qureshi, Ferhan; Eastman, P Scott; Manning, William C; Alexander, Claire; Robinson, William H; Hesterberg, Lyndal K

    2012-04-30

    Variability in pre-analytical blood sampling and handling can significantly impact results obtained in quantitative immunoassays. Understanding the impact of these variables is critical for accurate quantification and validation of biomarker measurements. Particularly, in the design and execution of large clinical trials, even small differences in sample processing and handling can have dramatic effects in analytical reliability, results interpretation, trial management and outcome. The effects of two common blood sampling methods (serum vs. plasma) and two widely-used serum handling methods (on the clot with ambient temperature shipping, "traditional", vs. centrifuged with cold chain shipping, "protocol") on protein and autoantibody concentrations were examined. Matched serum and plasma samples were collected from 32 rheumatoid arthritis (RA) patients representing a wide range of disease activity status. Additionally, a set of matched serum samples with two sample handling methods was collected. One tube was processed per manufacturer's instructions and shipped overnight on cold packs (protocol). The matched tube, without prior centrifugation, was simultaneously shipped overnight at ambient temperatures (traditional). Upon delivery, the traditional tube was centrifuged. All samples were subsequently aliquoted and frozen prior to analysis of protein and autoantibody biomarkers. Median correlation between paired serum and plasma across all autoantibody assays was 0.99 (0.98-1.00) with a median % difference of -3.3 (-7.5 to 6.0). In contrast, observed protein biomarker concentrations were significantly affected by sample types, with median correlation of 0.99 (0.33-1.00) and a median % difference of -10 (-55 to 23). When the two serum collection/handling methods were compared, the median correlation between paired samples for autoantibodies was 0.99 (0.91-1.00) with a median difference of 4%. In contrast, significant increases were observed in protein biomarker concentrations among certain biomarkers in samples processed with the 'traditional' method. Autoantibody quantification appears robust to both sample type (plasma vs. serum) and pre-analytical sample collection/handling methods (protocol vs. traditional). In contrast, for non-antibody protein biomarker concentrations, sample type had a significant impact; plasma samples generally exhibit decreased protein biomarker concentrations relative to serum. Similarly, sample handling significantly impacted the variability of protein biomarker concentrations. When biomarker concentrations are combined algorithmically into a single test score such as a multi-biomarker disease activity test for rheumatoid arthritis (MBDA), changes in protein biomarker concentrations may result in a bias of the score. These results illustrate the importance of characterizing pre-analytical methodology, sample type, sample processing and handling procedures for clinical testing in order to ensure test accuracy. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. DIBENZO-P-DIOXINS IN THE ENVIRONMENT FROM CERAMICS AND POTTERY PRODUCED FROM BALL CLAY MINED IN THE U.S.

    EPA Science Inventory

    Processed ball clay samples used in the production of ceramics and samples of the ceramic products were collected and analyzed for the presence and concentration of the 2,3,7,8-Cl substituted polychlorinated dibenzo-p-dioxins and furans (PCDDs/PCDFs). The processed ball clay had...

  4. Clean and Cold Sample Curation

    NASA Technical Reports Server (NTRS)

    Allen, C. C.; Agee, C. B.; Beer, R.; Cooper, B. L.

    2000-01-01

    Curation of Mars samples includes both samples that are returned to Earth, and samples that are collected, examined, and archived on Mars. Both kinds of curation operations will require careful planning to ensure that the samples are not contaminated by the instruments that are used to collect and contain them. In both cases, sample examination and subdivision must take place in an environment that is organically, inorganically, and biologically clean. Some samples will need to be prepared for analysis under ultra-clean or cryogenic conditions. Inorganic and biological cleanliness are achievable separately by cleanroom and biosafety lab techniques. Organic cleanliness to the <50 ng/sq cm level requires material control and sorbent removal - techniques being applied in our Class 10 cleanrooms and sample processing gloveboxes.

  5. Analysis of ECs and related compounds in plasma: artifactual isomerization and ex vivo enzymatic generation of 2-MGs.

    PubMed

    Pastor, Antoni; Farré, Magí; Fitó, Montserrat; Fernandez-Aranda, Fernando; de la Torre, Rafael

    2014-05-01

    The analysis of peripheral endocannabinoids (ECs) is a good biomarker of the EC system. Their concentrations, from clinical studies, strongly depend on sample collection and time processing conditions taking place in clinical and laboratory settings. The analysis of 2-monoacylglycerols (MGs) (i.e., 2-arachidonoylglycerol or 2-oleoylglycerol) is a particularly challenging issue because of their ex vivo formation and chemical isomerization that occur after blood sample collection. We provide evidence that their ex vivo formation can be minimized by adding Orlistat, an enzymatic lipase inhibitor, to plasma. Taking into consideration the low cost of Orlistat, we recommend its addition to plasma collecting tubes while maintaining sample cold chain until storage. We have validated a method for the determination of the EC profile of a range of MGs and N-acylethanolamides in plasma that preserves the original isomer ratio of MGs. Nevertheless, the chemical isomerization of 2-MGs can only be avoided by an immediate processing and analysis of samples due to their instability during conservation. We believe that this new methodology can aid in the harmonization of the measurement of ECs and related compounds in clinical samples.

  6. Insights in groundwater organic matter from Liquid Chromatography-Organic Carbon Detection

    NASA Astrophysics Data System (ADS)

    Rutlidge, H.; Oudone, P.; McDonough, L.; Andersen, M. S.; Baker, A.; Meredith, K.; O'Carroll, D. M.

    2017-12-01

    Understanding the processes that control the concentration and characteristics of organic matter in groundwater has important implications for the terrestrial global carbon budget. Liquid Chromatography - Organic Carbon Detection (LC-OCD) is a size-exclusion based chromatography technique that separates the organic carbon into molecular weight size fractions of biopolymers, humic substances, building blocks (degradation products of humic substances), low molecular weight acids and low molecular weight neutrals. Groundwater and surface water samples were collected from a range of locations in Australia representing different surface soil, land cover, recharge type and hydrological properties. At one site hyporheic zone samples were also collected from beneath a stream. The results showed a general decrease in the aromaticity and molecular weight indices going from surface water, hyporheic downwelling and groundwater samples. The aquifer substrate also affected the organic composition. For example, groundwater samples collected from a zone of fractured rock showed a relative decrease in the proportion of humic substances, suggestive of sorption or degradation of humic substances. This work demonstrates the potential for using LC-OCD in elucidating the processes that control the concentration and characteristics of organic matter in groundwater.

  7. Development and evaluation of a collection apparatus for recoil products for study of the deexcitation process of (235m)U.

    PubMed

    Shigekawa, Y; Kasamatsu, Y; Shinohara, A

    2016-05-01

    The nucleus (235m)U is an isomer with extremely low excitation energy (76.8 eV) and decays dominantly through the internal conversion (IC) process. Because outer-shell electrons are involved in the IC process, the decay constant of (235m)U depends on its chemical environment. We plan to study the deexcitation process of (235m)U by measuring the energy spectra of IC electrons in addition to the decay constants for various chemical forms. In this paper, the preparation method of (235m)U samples from (239)Pu by using alpha-recoil energy is reported. A Collection Apparatus for Recoil Products was fabricated, and then collection efficiencies under various conditions were determined by collecting (224)Ra recoiling out of (228)Th electrodeposited and precipitated sources. The pressure in the apparatus (vacuum or 1 atm of N2 gas) affected the variations of the collection efficiencies depending on the negative voltage applied to the collector. The maximum values of the collection efficiencies were mainly affected by the thickness of the (228)Th sources. From these results, the suitable conditions of the (239)Pu sources for preparation of (235m)U were determined. In addition, dissolution efficiencies were determined by washing collected (224)Ra with solutions. When (224)Ra was collected in 1 atm of N2 gas and dissolved with polar solutions such as water, the dissolution efficiencies were nearly 100%. The method of rapid dissolution of recoil products would be applicable to rapid preparation of short-lived (235m)U samples for various chemical forms.

  8. A nationwide survey of NDMA in raw and drinking water in Japan.

    PubMed

    Asami, Mari; Oya, Masami; Kosaka, Koji

    2009-05-15

    A nationwide survey of N-nitrosodimethylamine (NDMA) in both raw and finished water samples from drinking water treatment plants (DWTPs) in Japan was conducted. NDMA was analyzed by solid-phase extraction (SPE) followed by ultra performance liquid chromatography (UPLC) coupled with tandem mass spectrometry (MS/MS). NDMA was detected in 15 of 31 raw water samples collected in the summer at concentrations up to 2.6 ng/L, and in 9 of 28 raw water samples collected in winter at concentrations up to 4.3 ng/L. The NDMA concentrations were higher in raw water samples collected from treatment plants with catchment areas that have high population densities. The NDMA concentrations were higher in river water samples collected from the east and west of Japan than in those collected from other areas. NDMA was detected in 10 of 31 finished samples collected in summer at reduced concentrations of up to 2.2 ng/L, while 5 of 28 finished samples collected in winter showed NDMA concentrations up to 10 ng/L. The highest NDMA levels were detected in finished water samples collected from the Yodo River basin DWTP, which uses ozonation. Furthermore, evaluation of the process water produced at six advanced water treatment plants was conducted. Influent from the Yodo River indicated that the NDMA concentration increased during ozonation to as high as 20 ng/L, and then decreased with subsequent biological activated carbon treatment. To our knowledge, this is the first nationwide evaluation of NDMA concentrations in water conducted in Japan to date.

  9. Catalog of Apollo 17 rocks. Volume 1: Stations 2 and 3 (South Massif)

    NASA Technical Reports Server (NTRS)

    Ryder, Graham

    1993-01-01

    The Catalog of Apollo 17 Rocks is a set of volumes that characterize each of 334 individually numbered rock samples (79 larger than 100 g) in the Apollo 17 collection, showing what each sample is and what is known about it. Unconsolidated regolith samples are not included. The catalog is intended to be used by both researchers requiring sample allocations and a broad audience interested in Apollo 17 rocks. The volumes are arranged geographically, with separate volumes for the South Massif and Light Mantle, the North Massif, and two volumes for the mare plains. Within each volume, the samples are arranged in numerical order, closely corresponding with the sample collection stations. The present volume, for the South Massif and Light Mantle, describes the 55 individual rock fragments collected at Stations two, two-A, three, and LRV-five. Some were chipped from boulders, others collected as individual rocks, some by raking, and a few by picking from the soil in the processing laboratory. Information on sample collection, petrography, chemistry, stable and radiogenic isotopes, rock surface characteristics, physical properties, and curatorial processing is summarized and referenced as far as it is known up to early 1992. The intention has been to be comprehensive: to include all published studies of any kind that provide information on the sample, as well as some unpublished information. References which are primarily bulk interpretations of existing data or mere lists of samples are not generally included. Foreign language journals were not scrutinized, but little data appears to have been published only in such journals. We have attempted to be consistent in format across all of the volumes, and have used a common reference list that appears in all volumes. Where possible, ages based on Sr and Ar isotopes have been recalculated using the 'new' decay constants recommended by Steiger and Jager; however, in many of the reproduced diagrams the ages correspond with the 'old' decay constants. In this volume, mg' or Mg' = atomic Mg/(Mg +Fe).

  10. Capillary blood sampling as an alternative to venipuncture in the assessment of serum 25 hydroxyvitamin D levels.

    PubMed

    Dayre McNally, J; Matheson, Loren A; Sankaran, Koravangattu; Rosenberg, Alan M

    2008-11-01

    This study compared 25-hydroxyvitamin D [25(OH)D] measurements in capillary and venous blood samples collected, respectively by fingerprick and venipuncture. Capillary blood for measuring 25(OH)D has potential advantages by reducing blood volume required (2mL versus 0.3mL for venipuncture and capillary sampling, respectively), facilitating blood collection for those populations in whom venipuncture is difficult (e.g. infants and children), improving patient convenience and reducing costs associated with phlebotomy. The results demonstrated a highly significant relationship between 25(OH)D levels in serum derived from venous and capillary blood samples (r(2)=0.901). Despite statistically higher 25(OH)D levels in fingerprick samples (108+/-9nmol/L) compared with venipuncture samples (90+/-7nmol/L), the correlation between venous and capillary samples provides support for this approach as a practical alternative to venipuncture for vitamin D determination. However, clinical application may require the incorporation of a correction factor for the assessment of insufficiency, and research studies should avoid using the two methods interchangeably. Studying vitamin D's role in health and disease requires collection techniques and measurement methods that are reliable, reproducible, easily accessible, inexpensive and minimally burdensome to the patient. The option to collect patient samples by fingerprick may facilitate the collection process.

  11. Carbon XANES Data from Six Aerogel Picokeystones Cut from the Top and Bottom Sides of the Stardust Comet Sample Tray

    NASA Technical Reports Server (NTRS)

    Wirick, S.; Flynn, G. J.; Frank, D.; Sandford, S. A.; Zolensky, M. E.; Tsou, P.; Peltzer, C.; Jacobsen, C.

    2009-01-01

    Great care and a large effort was made to minimize the amount of organic matter contained within the flight aerogel used to collect Comet 81P/Wild 2 samples. Even so, by the very nature of the production process and silica aerogel s affinity for volatile organics keeping silica aerogel free from organics is a monumental task. Silica aerogel from three production batches was flown on the Stardust sample return mission. All 3 types had layered densities varying from 5mg/ml to 50 mg/ml where the densest aerogel was farthest away from the collection area. A 2 step gelation process was used to make the flight aerogel and organics used in this process were tetraethylorthosilicate, ethanol and acetonitrile. Both ammonium hydroxide and nitric acid were also used in the aerogel production process. The flight aerogel was baked at JPL at 300 C for 72 hours, most of the baking was done at atmosphere but twice a day the oven was pumped to 10 torr for hour [1]. After the aerogel was baked it was stored in a nitrogen purged cabinet until flight time. One aerogel cell was located in the SRC away from any sample collection area as a witness to possible contamination from out gassing of the space craft, re-entry gases and any other organic encounter. This aerogel was aerogel used in the interstellar collection sample tray and is the least dense of the 3 batches of aerogel flown. Organics found in the witness tile include organics containing Si-CH3 bonds, amines and PAHS. Besides organic contamination, hot spots of calcium were reported in the flight aerogel. Carbonates have been detected in comet 81P/Wild2 samples . During preflight analyses, no technique was used to analyze for carbonates in aerogel. To determine if the carbonates found in 81P/Wild2 samples were from the comet, it is necessary to analyze the flight aerogel for carbonate as well as for organics.

  12. Evaluation of a novel dried blood spot collection device (HemaSpot™) to test blood samples collected from dogs for antibodies to Leishmania infantum.

    PubMed

    Rosypal, Alexa C; Pick, Leanne D; Hernandez, Jaime O Esquivel; Lindsay, David S

    2014-09-15

    Collection of blood samples from veterinary and wildlife patients is often challenging because the samples have to be collected on farm or in the wild under various environmental conditions. This poses many technical problems associated with venipuncture materials, their safe use and disposal, transportation and processing of collected samples. Dried blood spot (DBS) sample collection techniques offer a simple and practical alternative to traditional blood collection methods to obtain blood samples from animals for parasite antibody evaluation. The DBS collection devices are compact, simple to use, and are particularly useful for large number of samples. Additionally, DBS samples take up less space and they are easier to transport than traditional venipuncture-collected blood samples. Visceral leishmaniasis (VL) is a potentially fatal parasitic disease of dogs and humans and it is frequently diagnosed by antibody tests. Immunochromatographic tests (ICT) for antibodies to Leishmania infantum are commercially available for dogs and they produce qualitative results in minutes. Measurement of canine antibodies to L. infantum with the ICT using traditional venipuncture has been validated previously, but the use of DBS samples has not been evaluated using this method. The purpose of the present study was to determine the ability of DBS samples to detect antibodies to L. infantum in dogs using a commercial ICT assay. One hundred plasma samples from dogs experimentally infected with the LIVT-1 strain of L. infantum were collected by venipuncture and frozen. Individual samples were thawed, and then 80 μl plasma (2 drops) was aliquotted onto the 8-spoked disk pad on individual DBS sample collection devices (HemaSpot™, Spot-On Sciences, Austin, TX), dried, and stored in the dark at room temperature. After one month and six months, respectively, 2 spokes of the 8 spokes of the disk pad of each DBS sample were removed and eluted in 200 μl PBS. The eluate was used to test for antibodies in the ICT and compared to ICT results using thawed plasma (same initial source). Sensitivity and specificity of the ICT using DBS were determined by using ICT results from traditional blood collection samples for comparison. After 1 month, DBS samples showed 100% sensitivity and specificity when compared to ICT results on thawed plasma samples collected by traditional venipuncture. After six months storage at room temperature, DBS samples demonstrated 79% sensitivity and 100% specificity compared to traditional blood collection. Results from this study indicate that dried blood spot collection may be a useful tool for screening dogs for antibodies to L. infantum with the ICT assay. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anheier, Norman C.; Cannon, Bret D.; Martinez, Alonzo

    The International Atomic Energy Agency’s (IAEA’s) long-term research and development plan calls for more cost-effective and efficient safeguard methods to detect and deter misuse of gaseous centrifuge enrichment plants (GCEPs). The IAEA’s current safeguards approaches at GCEPs are based on a combination of routine and random inspections that include environmental sampling and destructive assay (DA) sample collection from UF6 in-process material and selected cylinders. Samples are then shipped offsite for subsequent laboratory analysis. In this paper, a new DA sample collection and onsite analysis approach that could help to meet challenges in transportation and chain of custody for UF6 DAmore » samples is introduced. This approach uses a handheld sampler concept and a Laser Ablation, Laser Absorbance Spectrometry (LAARS) analysis instrument, both currently under development at the Pacific Northwest National Laboratory. A LAARS analysis instrument could be temporarily or permanently deployed in the IAEA control room of the facility, in the IAEA data acquisition cabinet, for example. The handheld PNNL DA sampler design collects and stabilizes a much smaller DA sample mass compared to current sampling methods. The significantly lower uranium mass reduces the sample radioactivity and the stabilization approach diminishes the risk of uranium and hydrogen fluoride release. These attributes enable safe sample handling needed during onsite LAARS assay and may help ease shipping challenges for samples to be processed at the IAEA’s offsite laboratory. The LAARS and DA sampler implementation concepts will be described and preliminary technical viability results presented.« less

  14. Sequential elution process

    DOEpatents

    Kingsley, I.S.

    1987-01-06

    A process and apparatus are disclosed for the separation of complex mixtures of carbonaceous material by sequential elution with successively stronger solvents. In the process, a column containing glass beads is maintained in a fluidized state by a rapidly flowing stream of a weak solvent, and the sample is injected into this flowing stream such that a portion of the sample is dissolved therein and the remainder of the sample is precipitated therein and collected as a uniform deposit on the glass beads. Successively stronger solvents are then passed through the column to sequentially elute less soluble materials. 1 fig.

  15. Effect of an isotonic lubricant on sperm collection and sperm quality.

    PubMed

    Agarwal, Ashok; Malvezzi, Helena; Sharma, Rakesh

    2013-05-01

    To assess the influence of an isotonic lubricant used during sperm sample collection on [1] ease of collection and [2] resultant sperm quality. Paired randomized cross-over design. Tertiary hospital. Healthy men over 18 years old with normal semen analysis as per World Health Organization 2010 guidelines. Collection of semen sample from 22 subjects by masturbation with or without the use of Pre-Seed personal lubricant. Qualitative survey results and quantitative sperm function outcomes were measured to determine resultant sperm quality and collection experience with and without Pre-Seed lubricant. The qualitative questionnaire results showed that 73% of donors prefer the semen collection process with the isotonic lubricant and 55% recommended the use of lubricant in their everyday collection. The motility, viability, membrane integrity, levels of reactive oxygen species, total antioxidant capacity, and percentage of DNA damage in collected semen samples were not affected by the use of the lubricant. More donors prefer, and find it easier, to collect semen samples with the use of the lubricant. The isotonic lubricant Pre-Seed did not compromise sperm quality as evaluated in an array of sperm assays, suggesting its safe use in fertility patients as required during sperm collection. Copyright © 2013 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  16. Acceptability of self-collection sampling for HPV-DNA testing in low-resource settings: a mixed methods approach.

    PubMed

    Bansil, Pooja; Wittet, Scott; Lim, Jeanette L; Winkler, Jennifer L; Paul, Proma; Jeronimo, Jose

    2014-06-12

    Vaginal self-sampling with HPV-DNA tests is a promising primary screening method for cervical cancer. However, women's experiences, concerns and the acceptability of such tests in low-resource settings remain unknown. In India, Nicaragua, and Uganda, a mixed-method design was used to collect data from surveys (N = 3,863), qualitative interviews (N = 72; 20 providers and 52 women) and focus groups (N = 30 women) on women's and providers' experiences with self-sampling, women's opinions of sampling at home, and their future needs. Among surveyed women, 90% provided a self- collected sample. Of these, 75% reported it was easy, although 52% were initially concerned about hurting themselves and 24% were worried about not getting a good sample. Most surveyed women preferred self-sampling (78%). However it was not clear if they responded to the privacy of self-sampling or the convenience of avoiding a pelvic examination, or both. In follow-up interviews, most women reported that they didn't mind self-sampling, but many preferred to have a provider collect the vaginal sample. Most women also preferred clinic-based screening (as opposed to home-based self-sampling), because the sample could be collected by a provider, women could receive treatment if needed, and the clinic was sanitary and provided privacy. Self-sampling acceptability was higher when providers prepared women through education, allowed women to examine the collection brush, and were present during the self-collection process. Among survey respondents, aids that would facilitate self-sampling in the future were: staff help (53%), additional images in the illustrated instructions (31%), and a chance to practice beforehand with a doll/model (26%). Self-and vaginal-sampling are widely acceptable among women in low-resource settings. Providers have a unique opportunity to educate and prepare women for self-sampling and be flexible in accommodating women's preference for self-sampling.

  17. Elevated plasma corticosterone concentrations influence the onset of rigor mortis and meat color in broilers.

    PubMed

    Kannan, G; Heath, J L; Wabeck, C J; Owens, S L; Mench, J A

    1998-02-01

    This experiment was conducted to determine the effect of elevated plasma corticosterone (CORT) levels on meat quality characteristics. Male broilers (Arbor Acres) were either 1) fed a diet containing corticosterone (CORT) prior to processing, 2) transported by truck for 3 h before processing, or 3) processed without either of the above treatments. Six crates of birds (10 birds per crate; two crates per treatment) were stunned or killed using CO2 gas. Six birds per crate were processed and blood samples were collected during exsanguination for plasma CORT analysis. Meat samples were collected from carcasses either at 20 min or at 4 h post-mortem. At each sampling time (ST), Pectoralis superficialis samples were collected and either individually quick frozen (IQF) in liquid nitrogen or aged on ice (AOI) for 24 h prior to pH, ratio of inosine to adenosine nucleotides (R-value), cooking loss, shear value, and color analyses. The IQF Biceps femoris samples were used for pH, R-value, color, and heme pigment analysis. Mean (+/- SEM) CORT concentrations were 12.9+/-2.57, 11.7+/-1.38 and 7.9+/-0.79 ng/mL, respectively, in the CORT, transported, and control groups. There were significant treatment by ST (P < 0.05) and ST (P < 0.001) effects on the R-value of IQF P. superficialis samples. The CORT group had the highest L* value (P < 0.01) and the lowest a* value (P < 0.06). There was also a significant main effect of ST on shear values (P < 0.05) of AOI P. superficialis samples, with the means higher at 4 h than at 20 min post-mortem. The R-value of IQF B. femoris samples was markedly influenced by treatment (P < 0.001) and ST (P < 0.001). The results indicate that artificially elevating circulating CORT concentrations results in lighter meat color in broilers.

  18. Questa baseline and pre-mining ground-water quality investigation. 2. Low-flow (2001) and snowmelt (2002) synoptic/tracer water chemistry for the Red River, New Mexico

    USGS Publications Warehouse

    McCleskey, R. Blaine; Nordstrom, D. Kirk; Steiger, Judy I.; Kimball, Briant A.; Verplanck, Philip L.

    2003-01-01

    Water analyses are reported for 259 samples collected from the Red River, New Mexico, and its tributaries during low-flow(2001) and spring snowmelt (2002) tracer studies. Water samples were collected along a 20-kilometer reach of the Red River beginning just east of the town of Red River and ending at the U.S. Geological Survey streamflow-gaging station located east of Questa, New Mexico. The study area was divided into three sections where separate injections and synoptic sampling events were performed during the low-flow tracer study. During the spring snowmelt tracer study, three tracer injections and synoptic sampling events were performed bracketing the areas with the greatest metal loading into the Red River as determined from the low-flow tracer study. The lowflow tracer synoptic sampling events were August 17, 20, and 24, 2001. The synoptic sampling events for the spring snowmelt tracer were March 30, 31, and April 1, 2002. Stream and large inflow water samples were sampled using equal-width and depth-integrated sampling methods and composited into half-gallon bottles. Grab water samples were collected from smaller inflows. Stream temperatures were measured at the time of sample collection. Samples were transported to a nearby central processing location where pH and specific conductance were measured and the samples processed for chemical analyses. Cations, trace metals, iron redox species, and fluoride were analyzed at the U.S. Geological Survey laboratory in Boulder, Colorado. Cations and trace metal concentrations were determined using inductively coupled plasma-optical emission spectrometry and graphite furnace atomic absorption spectrometry. Arsenic concentrations were determined using hydride generation atomic absorption spectrometry, iron redox species were measured using ultraviolet-visible spectrometry, and fluoride concentrations were determined using an ion-selective electrode. Alkalinity was measured by automated titration, and sulfate, chloride, and bromide were analyzed by ion chromatography at the U.S. Geological Survey laboratory in Salt Lake City, Utah.

  19. Chemical constituents in clouds and rainwater in the Puerto Rican rainforest: potential sources and seasonal drivers

    Treesearch

    A. Gioda; O.L. Mayol-Bracero; F. N. Scatena; K. C. Weathers; V. L. Mateus; W. H. McDowell

    2013-01-01

    Cloud- and rain-water samples collected between 1984 and 2007 in the Luquillo Experimental Forest, Puerto Rico, were analyzed in order to understand the main processes and sources that control their chemistry. Three sites were used: El Verde Field Station (380 m asl), Bisley (361 m asl), and East Peak (1051 m asl). Bulk rainwater samples were collected from all sites,...

  20. Effects of sample handling methods on substance P concentrations and immunoreactivity in bovine blood samples.

    PubMed

    Mosher, Ruby A; Coetzee, Johann F; Allen, Portia S; Havel, James A; Griffith, Gary R; Wang, Chong

    2014-02-01

    To determine the effects of protease inhibitors and holding times and temperatures before processing on the stability of substance P in bovine blood samples. Blood samples obtained from a healthy 6-month-old calf. Blood samples were dispensed into tubes containing exogenous substance P and 1 of 6 degradative enzyme inhibitor treatments: heparin, EDTA, EDTA with 1 of 2 concentrations of aprotinin, or EDTA with 1 of 2 concentrations of a commercially available protease inhibitor cocktail. Plasma was harvested immediately following collection or after 1, 3, 6, 12, or 24 hours of holding at ambient (20.3° to 25.4°C) or ice bath temperatures. Total substance P immunoreactivity was determined with an ELISA; concentrations of the substance P parent molecule, a metabolite composed of the 9 terminal amino acids, and a metabolite composed of the 5 terminal amino acids were determined with liquid chromatography-tandem mass spectrometry. Regarding blood samples processed immediately, no significant differences in substance P concentrations or immunoreactivity were detected among enzyme inhibitor treatments. In blood samples processed at 1 hour of holding, substance P parent molecule concentration was significantly lower for ambient temperature versus ice bath temperature holding conditions; aprotinin was the most effective inhibitor of substance P degradation at the ice bath temperature. The ELISA substance P immunoreactivity was typically lower for blood samples with heparin versus samples with other inhibitors processed at 1 hour of holding in either temperature condition. Results suggested that blood samples should be chilled and plasma harvested within 1 hour after collection to prevent substance P degradation.

  1. Pods: a Powder Delivery System for Mars In-situ Organic, Mineralogic and Isotopic Analysis Instruments

    NASA Technical Reports Server (NTRS)

    Saha, C. P.; Bryson, C. E.; Sarrazin, P.; Blake, D. F.

    2005-01-01

    Many Mars in situ instruments require fine-grained high-fidelity samples of rocks or soil. Included are instruments for the determination of mineralogy as well as organic and isotopic chemistry. Powder can be obtained as a primary objective of a sample collection system (e.g., by collecting powder as a surface is abraded by a rotary abrasion tool (RAT)), or as a secondary objective (e.g, by collecting drill powder as a core is drilled). In the latter case, a properly designed system could be used to monitor drilling in real time as well as to deliver powder to analytical instruments which would perform complementary analyses to those later performed on the intact core. In addition, once a core or other sample is collected, a system that could transfer intelligently collected subsamples of power from the intact core to a suite of analytical instruments would be highly desirable. We have conceptualized, developed and tested a breadboard Powder Delivery System (PoDS) intended to satisfy the collection, processing and distribution requirements of powder samples for Mars in-situ mineralogic, organic and isotopic measurement instruments.

  2. Wells provide a distorted view of life in the aquifer: implications for sampling, monitoring and assessment of groundwater ecosystems

    PubMed Central

    Korbel, Kathryn; Chariton, Anthony; Stephenson, Sarah; Greenfield, Paul; Hose, Grant C.

    2017-01-01

    When compared to surface ecosystems, groundwater sampling has unique constraints, including limited access to ecosystems through wells. In order to monitor groundwater, a detailed understanding of groundwater biota and what biological sampling of wells truly reflects, is paramount. This study aims to address this uncertainty, comparing the composition of biota in groundwater wells prior to and after purging, with samples collected prior to purging reflecting a potentially artificial environment and samples collected after purging representing the surrounding aquifer. This study uses DNA community profiling (metabarcoding) of 16S rDNA and 18S rDNA, combined with traditional stygofauna sampling methods, to characterise groundwater biota from four catchments within eastern Australia. Aquifer waters were dominated by Archaea and bacteria (e.g. Nitrosopumilales) that are often associated with nitrification processes, and contained a greater proportion of bacteria (e.g. Anaerolineales) associated with fermenting processes compared to well waters. In contrast, unpurged wells contained greater proportions of pathogenic bacteria and bacteria often associated with denitrification processes. In terms of eukaryotes, the abundances of copepods, syncarids and oligochaetes and total abundances of stygofauna were greater in wells than aquifers. These findings highlight the need to consider sampling requirements when completing groundwater ecology surveys. PMID:28102290

  3. Disposable Collection Kit for Rapid and Reliable Collection of Saliva

    PubMed Central

    Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek

    2015-01-01

    Objectives To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. Methods The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 μl) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method on subsequent immunoassay results was verified by assessing salivary cortisol levels in the samples and comparing them to controls. Results The recovered volumes for the whole saliva samples were 3.85 ± 0.28, 10.79 ± 0.95, and 31.18 ± 1.72 μl, respectively (CV = 8.76%) and 2.91 ± 0.19, 9.75 ± 0.43, and 29.64 ± 0.91 μl, respectively, (CV = 6.36%) for the controls. There was a close correspondence between the salivary cortisol levels from the saliva samples obtained by the collection kit and the controls (R2 > 0.96). Conclusions The disposable saliva collection kit allows accurate and repeatable collection of fixed amounts of whole saliva and does not interfere with subsequent measurements of salivary cortisol. The simple collection process, lack of elaborate specimen recovery steps, and the short turnaround time (<3 min) should render the kit attractive to test subjects and researchers alike. Am. J. Hum. Biol. 27:720–723, 2015. © 2015 The Authors American Journal of Human Biology Published by Wiley Periodicals, Inc. PMID:25754371

  4. Levels and distribution of polybrominated diphenyl ethers in soil, sediment and dust samples collected from various electronic waste recycling sites within Guiyu town, southern China.

    PubMed

    Labunska, Iryna; Harrad, Stuart; Santillo, David; Johnston, Paul; Brigden, Kevin

    2013-02-01

    Electronic waste recycling operations in some parts of Asia are conducted using rudimentary techniques which result in workplace and environmental contamination with toxic metals and persistent organic pollutants. This study reports concentrations of 14 polybrominated diphenyl ethers (PBDEs), from tri- to deca-brominated, in 31 samples of soil, sediment, dust or ash collected in the vicinity of e-waste recycling sites in Guiyu (southeast China) which were engaged in common activities such as dismantling, shredding, solder recovery, acid processing and open burning. The concentrations detected in this study far exceed those reported previously in urban soil and sediment and are consistent with or exceed those reported in previous studies around e-waste processing facilities. Some of the highest PBDE concentrations reported to date (e.g. 390 000 ng g (-1) dw (∑ 14 PBDEs)) were found in a sample collected from a site used for open-burning of e-waste, while an average concentration of 220 000 ng g (-1) dw (∑ 14 PBDEs) occurred in sediments impacted by circuit board shredding. A decrease in PBDE concentrations observed with increasing distance from workshops in samples associated with acid processing of wastes provides evidence that such operations are a significant source of PBDEs to the environment. Principal components analysis reveals a complex PBDE congener distribution, suggesting contamination by two or even three commercial formulations consistent with the diverse range of wastes processed.

  5. Surface-water-quality assessment of the Kentucky River Basin, Kentucky; fixed-station network and selected water-quality data, April 1987 through August 1991

    USGS Publications Warehouse

    Griffin, M.S.; Martin, G.R.; White, K.D.

    1994-01-01

    This report describes selected data-collection activities and the associated data collected during the Kentucky River Basin pilot study of the U.S. Geological Survey's National Water-Quality Assessment Program. The data are intended to provide a nationally consistent description and improved understanding of current water quality in the basin. The data were collected at seven fixed stations that represent stream cross sections where constituent transport and water-quality trends can be evaluated. The report includes descriptions of (1) the basin; (2) the design of the fixed-station network; (3) the fixed-station sites; (4) the physical and chemical measurements; (5) the methods of sample collection, processing, and analysis; and (6) the quality-assurance and quality-control procedures. Water-quality data collected at the fixed stations during routine periodic sampling and supplemental high-flow sampling from April 1987 to August 1991 are presented.

  6. unmarked: An R package for fitting hierarchical models of wildlife occurrence and abundance

    USGS Publications Warehouse

    Fiske, Ian J.; Chandler, Richard B.

    2011-01-01

    Ecological research uses data collection techniques that are prone to substantial and unique types of measurement error to address scientific questions about species abundance and distribution. These data collection schemes include a number of survey methods in which unmarked individuals are counted, or determined to be present, at spatially- referenced sites. Examples include site occupancy sampling, repeated counts, distance sampling, removal sampling, and double observer sampling. To appropriately analyze these data, hierarchical models have been developed to separately model explanatory variables of both a latent abundance or occurrence process and a conditional detection process. Because these models have a straightforward interpretation paralleling mechanisms under which the data arose, they have recently gained immense popularity. The common hierarchical structure of these models is well-suited for a unified modeling interface. The R package unmarked provides such a unified modeling framework, including tools for data exploration, model fitting, model criticism, post-hoc analysis, and model comparison.

  7. Evaluation of Sources of Nitrate Beneath Food Processing Wastewater-Application Sites near Umatilla, Oregon

    USGS Publications Warehouse

    Frans, Lonna; Paulson, Anthony; Richerson, Phil; Striz, Elise; Black, Curt

    2009-01-01

    Water samples from wells were collected beneath and downgradient of two food-processing wastewater-application sites near Umatilla, Oregon. These samples were analyzed for nitrate stable isotopes, nutrients, major ions, and age-dating constituents to determine if nitrate-stable isotopes can be used to differentiate food-processing waste from other potential sources of nitrate. Major-ion data from each site were used to determine which samples were associated with the recharge of the food-processing wastewater. End-member mixing analysis was used to determine the relative amounts of each identified end member within the samples collected from the Terrace Farm site. The delta nitrogen-15 (delta 15N) of nitrate generally ranged between +2 and +9 parts per thousand and the delta oxygen-18 (delta 18O) of nitrate generally ranged between -2 and -7 parts per thousand. None of the samples that were determined to be associated with the wastewater were different from the samples that were not affected by the wastewater. The nitrate isotope values measured in this study are also characteristic of ammonium fertilizer, animal and human waste, and soil nitrate; therefore, it was not possible to differentiate between food-processing wastewater and the other nitrate sources. Values of delta 15N and delta 18O of nitrate provided no more information about the sources of nitrate in the Umatilla River basin than did a hydrologic and geochemical understanding of the ground-water system derived from interpreting water-level and major-ion chemistry data.

  8. Collective Efficacy in Sports and Physical Activities: Perceived Emotional Synchrony and Shared Flow.

    PubMed

    Zumeta, Larraitz N; Oriol, Xavier; Telletxea, Saioa; Amutio, Alberto; Basabe, Nekane

    2015-01-01

    This cross-sectional study analyzes the relationship between collective efficacy and two psychosocial processes involved in collective sport-physical activities. It argues that in-group identification and fusion with the group will affect collective efficacy (CE). A sample of 276 university students answered different scales regarding their participation in collective physical and sport activities. Multiple-mediation analyses showed that shared flow and perceived emotional synchrony mediate the relationship between in-group identification and CE, whereas the relationship between identity fusion and CE was only mediated by perceived emotional synchrony. Results suggest that both psychosocial processes explain the positive effects of in-group identification and identity fusion with the group in collective efficacy. Specifically, the role of perceived emotional synchrony in explaining the positive effects of participation in collective sport-physical activities is underlined. In sum, this study highlights the utility of collective actions and social identities to explain the psychosocial processes related to collective efficacy in physical and sports activities. Finally, practical implications are discussed.

  9. Collective Efficacy in Sports and Physical Activities: Perceived Emotional Synchrony and Shared Flow

    PubMed Central

    Zumeta, Larraitz N.; Oriol, Xavier; Telletxea, Saioa; Amutio, Alberto; Basabe, Nekane

    2016-01-01

    This cross-sectional study analyzes the relationship between collective efficacy and two psychosocial processes involved in collective sport-physical activities. It argues that in-group identification and fusion with the group will affect collective efficacy (CE). A sample of 276 university students answered different scales regarding their participation in collective physical and sport activities. Multiple-mediation analyses showed that shared flow and perceived emotional synchrony mediate the relationship between in-group identification and CE, whereas the relationship between identity fusion and CE was only mediated by perceived emotional synchrony. Results suggest that both psychosocial processes explain the positive effects of in-group identification and identity fusion with the group in collective efficacy. Specifically, the role of perceived emotional synchrony in explaining the positive effects of participation in collective sport-physical activities is underlined. In sum, this study highlights the utility of collective actions and social identities to explain the psychosocial processes related to collective efficacy in physical and sports activities. Finally, practical implications are discussed. PMID:26779077

  10. Evaluation of Trapper-Collected Nobuto Filter-Paper Blood Samples for Distemper and Parvovirus Antibody Detection in Coyotes (Canis latrans) and Raccoons (Procyon lotor).

    PubMed

    Kamps, Amanda J; Dubay, Shelli A; Langenberg, Julie; Maes, Roger K

    2015-07-01

    Blood samples are often collected from free-ranging wildlife for antibody detection. However, filter-paper (FP) strips are more cost efficient and easy to collect and store. We evaluated trapper-collected FP strips and body-cavity blood for canine distemper (CDV) and parvovirus (CPV-2) antibody detection in raccoons (Procyon lotor) and coyotes (Canis latrans). From 2008 to 2010, licensed trappers near Madison and Milwaukee, Wisconsin, US collected paired samples from harvested animals. Canine distemper antibodies were detected using virus neutralization and parvovirus antibodies were detected using hemagglutination inhibition. Titers ≥ 1:32 for CDV and ≥ 1:25 for CPV-2 were considered evidence of exposure. Using Cohen's kappa test of agreement, FP strip titers agreed with sera for CDV in coyotes (n = 28, K = 0.772) and raccoons (n = 29, K = 0.858) and for CPV-2 in coyotes (n = 40, K = 0.775) and raccoons (n = 70, K = 0.646). However, raccoons determined to be exposed to CPV-2 from sera were unexposed by FP strips in 35% of the samples. Titer results may be affected by quality and volume of blood samples, interval between collection and processing, small sample sizes, and diagnostic testing procedures. Filter-paper strips can be useful for detecting CDV and CPV-2 exposure in coyotes and raccoons with correct field sample collection and appropriate diagnostic testing procedures.

  11. Environmental sampling and analysis in support of NTI-3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGuire, R.R.; Harrar, J.E.; Haas, J.S.

    1991-04-06

    The third National Trail Inspection took place at the Monsanto Chemical Plant in Luling, Louisiana. In order to test the effectiveness of environmental sampling (soil, water and air) in determining the nature of the chemical process in a given production plant and to examine the distance from a process building that samples can effectively be taken, we needed to select some materials that constituted components of process streams. Three materials were selected: 1. isopropyl amine for air monitoring, 2. 4-nitrophenol, one of the precursors in the acetaminophen process, and 3. an intermediate in the production of glyphosate for ROUNDUP thatmore » is known simply as glyphosate intermediated. LLNL did not participate in the air sampling nor the analysis for isopropyl amine. This paper discussed the steps in this experiment including sample collection, sample workshop, sample analysis the results and discussion and the conclusion. 3 figs., 6 tabs.« less

  12. Radiochemical sampling and analysis of shallow ground water and sediment at the BOMARC Missile Facility, east-central New Jersey, 1999-2000

    USGS Publications Warehouse

    Szabo, Zoltan; Zapecza, Otto S.; Oden, Jeannette H.; Rice, Donald E.

    2005-01-01

    A field sampling experiment was designed using low-flow purging with a portable pump and sample-collection equipment for the collection of water and sediment samples from observation wells screened in the Kirkwood-Cohansey aquifer system to determine radionuclide or trace-element concentrations for various size fractions. Selected chemical and physical characteristics were determined for water samples from observation wells that had not been purged for years. The sampling was designed to define any particulate, colloidal, and solution-phase associations of radionuclides or trace elements in ground water by means of filtration and ultrafiltration techniques. Turbidity was monitored and allowed to stabilize before samples were collected by means of the low-flow purging technique rather than by the traditional method of purging a fixed volume of water at high-flow rates from the observation well. A minimum of four water samples was collected from each observation well. The samples of water from each well were collected in the following sequence. (1) A raw unfiltered sample was collected within the first minutes of pumping. (2) A raw unfiltered sample was collected after at least three casing volumes of water were removed and turbidity stabilized. (3) A sample was collected after the water was filtered with a 0.45-micron filter. (4) A sample was collected after the water passed through a 0.45-micron filter and a 0.003-micron tangential-flow ultrafilter in sequence. In some cases, a fifth sample was collected after the water passed through a 0.45-micron filter and a 0.05-micron filter in sequence to test for colloids of 0.003 microns to 0.05 microns in size. The samples were analyzed for the concentration of manmade radionuclides plutonium-238 and -239 plus -240, and americium-241. The samples also were analyzed for concentrations of uranium-234, -235, and -238 to determine whether uranium-234 isotope enrichment (resulting from industrial processing) is present. A subset of samples was analyzed for concentrations of thorium-232, -230, and -228 to determine if thorium-228 isotope enrichment, also likely to result from industrial processing, is present. Concentrations of plutonium isotopes and americium-241 in the water samples were less than 0.1 picocurie per liter, the laboratory reporting level for these manmade radionuclides, with the exception of one americium-241 concentration from a filtered sample. A sequential split sample from the same well did not contain a detectable concentration of americium-241, however. Other filtered and unfiltered samples of water from the same well did not contain quantities of americium-241 nearly as high as 0.1 pCi/L. Therefore, the presence of americium-241 in a quantifiable concentration in water samples from this well could not be confirmed. Neither plutonium nor americium was detected in samples of settled sediment collected from the bottom of the wells. Concentrations of uranium isotopes (maximum of 0.05 and 0.08 picocuries per liter of uranium-238 and uranium-234, respectively) were measurable in unfiltered samples of turbid water from one well and in the settled bottom sediment from 6 wells (maximum concentrations of 0.25 and 0.20 picocuries per gram of uranium-238 and uranium-234, respectively). The uranium-234/uranium-238 isotopic ratio was near 1:1, which indicates natural uranium. The analytical results, therefore, indicate that no manmade radionuclide contamination is present in any of the well-bottom sediments, or unfiltered or filtered water samples from any of the sampled wells. No evidence of manmade radionuclide contamination was observed in the aquifer as settled or suspended particulates, colloids, or in the dissolved phase.

  13. Adaptive Sensing of Time Series with Application to Remote Exploration

    NASA Technical Reports Server (NTRS)

    Thompson, David R.; Cabrol, Nathalie A.; Furlong, Michael; Hardgrove, Craig; Low, Bryan K. H.; Moersch, Jeffrey; Wettergreen, David

    2013-01-01

    We address the problem of adaptive informationoptimal data collection in time series. Here a remote sensor or explorer agent throttles its sampling rate in order to track anomalous events while obeying constraints on time and power. This problem is challenging because the agent has limited visibility -- all collected datapoints lie in the past, but its resource allocation decisions require predicting far into the future. Our solution is to continually fit a Gaussian process model to the latest data and optimize the sampling plan on line to maximize information gain. We compare the performance characteristics of stationary and nonstationary Gaussian process models. We also describe an application based on geologic analysis during planetary rover exploration. Here adaptive sampling can improve coverage of localized anomalies and potentially benefit mission science yield of long autonomous traverses.

  14. [Avian influenza virus in various environments and risk factors for the contamination of live poultry markets during winter and spring season in Zhejiang province].

    PubMed

    Wang, Xiaoxiao; Cheng, Wei; Yu, Zhao; Mao, Haiyan; Chen, Enfu

    2016-03-01

    To evaluate the prevalence of avian influenza virus in various environment and the influence factors for subtype H7 prevalence in live poultry markets. We collected environmental samples from various environments across 11 cities of Zhejiang province between October 2014 and March 2015. Cage surface swabs, chopping board surface swabs, feces, water for cleaning, drinking water and swabs of other surfaces were collected. A total of 6 457 samples were collected, including 4 487 samples from poultry markets, 820 samples from poultry farms, 715 samples from backyard poultry pens, 118 samples from poultry processing factories, 118 samples from wild bird habitats and 86 samples from other sites. The chi-squared test was used to compare virus prevalence among sample types, sites types, and poultry markets types. Binary logistic regression was used to analyze factors on H7 subtype prevalence in poultry markets. Of 6 457 samples, 32.54% (2 101) samples were positive for avian influenza, with 3.67% (237) positive for H5 subtype, 12.02%(776) positive for H7 subtype, 11.77%(760) positive for H9 subtype. Of 237 live poultry markets, 33.8% (80) were positive for H7 subtype. The prevalence of influenza A in poultry processing factories was the highest at 43.72% (101/231) (χ(2)=737.80, P<0.001). Poultry markets were contaminated most seriously by subtype H5/H7/H9 with the prevalence of 27.55% (1 236/4 487) (χ(2)=436.37, P<0.001). Compared with markets with 1 type of poultry, OR was 4.58 (95%CI: 1.63-12.87) for markets with ≥2 types of poultry. Live poultry markets and poultry processing factories were contaminated most seriously by avian influenza. The types of poultry might be the factor which influenced the subtype H7 prevalence in poultry markets.

  15. Changes in the microbial communities during co-composting of digestates.

    PubMed

    Franke-Whittle, Ingrid H; Confalonieri, Alberto; Insam, Heribert; Schlegelmilch, Mirko; Körner, Ina

    2014-03-01

    Anaerobic digestion is a waste treatment method which is of increasing interest worldwide. At the end of the process, a digestate remains, which can gain added value by being composted. A study was conducted in order to investigate microbial community dynamics during the composting process of a mixture of anaerobic digestate (derived from the anaerobic digestion of municipal food waste), green wastes and a screened compost (green waste/kitchen waste compost), using the COMPOCHIP microarray. The composting process showed a typical temperature development, and the highest degradation rates occurred during the first 14 days of composting, as seen from the elevated CO2 content in the exhaust air. With an exception of elevated nitrite and nitrate levels in the day 34 samples, physical-chemical parameters for all compost samples collected during the 63 day process indicated typical composting conditions. The microbial communities changed over the 63 days of composting. According to principal component analysis of the COMPOCHIP microarray results, compost samples from the start of the experiment were found to cluster most closely with the digestate and screened compost samples. The green waste samples were found to group separately. All starting materials investigated were found to yield fewer and lower signals when compared to the samples collected during the composting experiment. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. Large-Scale Variability of Inpatient Tacrolimus Therapeutic Drug Monitoring at an Academic Transplant Center: a Retrospective Study.

    PubMed

    Strohbehn, Garth W; Pan, Warren W; Petrilli, Christopher M; Heidemann, Lauren; Larson, Sophia; Aaronson, Keith D; Johnson, Matt; Ellies, Tammy; Heung, Michael

    2018-04-30

    Inpatient tacrolimus therapeutic drug monitoring (TDM) lacks standardized guidelines. In this study, the authors analyzed variability in the pre-analytical phase of the inpatient tacrolimus TDM process at their institution. Patients receiving tacrolimus (twice-daily formulation) and tacrolimus laboratory analysis were included in the study. Times of tacrolimus administration and laboratory study collection were extracted and time distribution plots for each step in the inpatient TDM process were generated. Trough levels were drawn appropriately in 25.9% of the cases. Timing between doses was consistent, with 91.9% of the following dose administrations occurring 12 +/- 2 hours after the previous dose. Only 38.1% of the drug administrations occurred within one hour of laboratory study collection. Tacrolimus-related patient safety events were reported at a rate of 1.9 events per month while incorrect timing of TDM sample collection occurred approximately 200 times per month. Root cause analysis identified a TDM process marked by a lack of communication and coordination of drug administration and TDM sample collection. Extrapolating findings nationwide, we estimate $22 million in laboratory costs wasted annually. Based on this large single-center study, the authors concluded that the inpatient TDM process is prone to timing errors, thus is financially wasteful, and at its worst harmful to patients due to clinical decisions being made on the basis of unreliable data. Further work is needed on systems solutions to better align the laboratory study collection and drug administration processes.

  17. Prevalence of Salmonella in poultry processing environments in wet markets in Penang and Perlis, Malaysia.

    PubMed

    Nidaullah, Hafiz; Abirami, Nadarajan; Shamila-Syuhada, Ahamed Kamal; Chuah, Li-Oon; Nurul, Huda; Tan, Teik Pei; Abidin, Farah Wahida Zainal; Rusul, Gulam

    2017-03-01

    The aim of this study was to determine the prevalence of various Salmonella serotypes in chickens, carcass contact surfaces as well as environmental samples collected from wet markets and small scale processing plant. A total of 182 poultry and environmental samples were collected at random on separate occasions from wet markets and small scale processing plant, during the period of October 2014 to July 2015 in Penang and Perlis, Malaysia. The samples were analyzed for the presence of Salmonella using ISO 6579:2002 conventional culture-based method. Presumptive Salmonella colonies were subjected to various biochemical tests (such as triple sugar iron and lysine iron test), serologically confirmed using polyvalent O and H antisera and further serotyped at Public Health Laboratory, Ministry of Health, Perak, Malaysia. Salmonella serotypes were isolated from 161 out of 182 samples (88.46%) with 100% prevalence in the whole chicken carcass and chicken cuts - as well as transport crate, cage, drum, knife, chopping board, display table, floor, bench wash water, wash water, and drain water. Salmonella was isolated from 91.67%, 83.33%, and 66.67% of defeathering machines, drain swabs, and apron, respectively. 17 serotypes were isolated in this study with Salmonella Albany (57/161), Salmonella Corvallis (42/161), and Salmonella Brancaster (37/161) being the predominant serovars. The most carcass contact and environmental samples collected along the wet market chicken processing line were consistently contaminated with Salmonella . This indicates that Salmonella has established itself in poultry processing environments by colonizing the surfaces of the equipment and survives in these environments by establishing biofilms. Our results highlight the need of implementing strict hygiene and sanitation standards to reduce the incidence of Salmonella . The prevalence of Salmonella in poultry can be reduced effectively by identifying and eliminating the sources and contamination sites during slaughter and processing of poultry.

  18. Prevalence of Salmonella in poultry processing environments in wet markets in Penang and Perlis, Malaysia

    PubMed Central

    Nidaullah, Hafiz; Abirami, Nadarajan; Shamila-Syuhada, Ahamed Kamal; Chuah, Li-Oon; Nurul, Huda; Tan, Teik Pei; Abidin, Farah Wahida Zainal; Rusul, Gulam

    2017-01-01

    Aim: The aim of this study was to determine the prevalence of various Salmonella serotypes in chickens, carcass contact surfaces as well as environmental samples collected from wet markets and small scale processing plant. Materials and Methods: A total of 182 poultry and environmental samples were collected at random on separate occasions from wet markets and small scale processing plant, during the period of October 2014 to July 2015 in Penang and Perlis, Malaysia. The samples were analyzed for the presence of Salmonella using ISO 6579:2002 conventional culture-based method. Presumptive Salmonella colonies were subjected to various biochemical tests (such as triple sugar iron and lysine iron test), serologically confirmed using polyvalent O and H antisera and further serotyped at Public Health Laboratory, Ministry of Health, Perak, Malaysia. Results: Salmonella serotypes were isolated from 161 out of 182 samples (88.46%) with 100% prevalence in the whole chicken carcass and chicken cuts - as well as transport crate, cage, drum, knife, chopping board, display table, floor, bench wash water, wash water, and drain water. Salmonella was isolated from 91.67%, 83.33%, and 66.67% of defeathering machines, drain swabs, and apron, respectively. 17 serotypes were isolated in this study with Salmonella Albany (57/161), Salmonella Corvallis (42/161), and Salmonella Brancaster (37/161) being the predominant serovars. Conclusion: The most carcass contact and environmental samples collected along the wet market chicken processing line were consistently contaminated with Salmonella. This indicates that Salmonella has established itself in poultry processing environments by colonizing the surfaces of the equipment and survives in these environments by establishing biofilms. Our results highlight the need of implementing strict hygiene and sanitation standards to reduce the incidence of Salmonella. The prevalence of Salmonella in poultry can be reduced effectively by identifying and eliminating the sources and contamination sites during slaughter and processing of poultry. PMID:28435190

  19. Benthic macroinvertebrate field sampling effort required to ...

    EPA Pesticide Factsheets

    This multi-year pilot study evaluated a proposed field method for its effectiveness in the collection of a benthic macroinvertebrate sample adequate for use in the condition assessment of streams and rivers in the Neuquén Province, Argentina. A total of 13 sites, distributed across three rivers, were sampled. At each site, benthic macroinvertebrates were collected at 11 transects. Each sample was processed independently in the field and laboratory. Based on a literature review and resource considerations, the collection of 300 organisms (minimum) at each site was determined to be necessary to support a robust condition assessment, and therefore, selected as the criterion for judging the adequacy of the method. This targeted number of organisms was collected at all sites, at a minimum, when collections from all 11 transects were combined. Subsequent bootstrapping analysis of data was used to estimate whether collecting at fewer transects would reach the minimum target number of organisms for all sites. In a subset of sites, the total number of organisms frequently fell below the target when fewer than 11 transects collections were combined.Site conditions where <300 organisms might be collected are discussed. These preliminary results suggest that the proposed field method results in a sample that is adequate for robust condition assessment of the rivers and streams of interest. When data become available from a broader range of sites, the adequacy of the field

  20. Method and apparatus for processing a test sample to concentrate an analyte in the sample from a solvent in the sample

    DOEpatents

    Turner, Terry D.; Beller, Laurence S.; Clark, Michael L.; Klingler, Kerry M.

    1997-01-01

    A method of processing a test sample to concentrate an analyte in the sample from a solvent in the sample includes: a) boiling the test sample containing the analyte and solvent in a boiling chamber to a temperature greater than or equal to the solvent boiling temperature and less than the analyte boiling temperature to form a rising sample vapor mixture; b) passing the sample vapor mixture from the boiling chamber to an elongated primary separation tube, the separation tube having internal sidewalls and a longitudinal axis, the longitudinal axis being angled between vertical and horizontal and thus having an upper region and a lower region; c) collecting the physically transported liquid analyte on the internal sidewalls of the separation tube; and d) flowing the collected analyte along the angled internal sidewalls of the separation tube to and pass the separation tube lower region. The invention also includes passing a turbulence inducing wave through a vapor mixture to separate physically transported liquid second material from vaporized first material. Apparatus are also disclosed for effecting separations. Further disclosed is a fluidically powered liquid test sample withdrawal apparatus for withdrawing a liquid test sample from a test sample container and for cleaning the test sample container.

  1. Method and apparatus for processing a test sample to concentrate an analyte in the sample from a solvent in the sample

    DOEpatents

    Turner, T.D.; Beller, L.S.; Clark, M.L.; Klingler, K.M.

    1997-10-14

    A method of processing a test sample to concentrate an analyte in the sample from a solvent in the sample includes: (a) boiling the test sample containing the analyte and solvent in a boiling chamber to a temperature greater than or equal to the solvent boiling temperature and less than the analyte boiling temperature to form a rising sample vapor mixture; (b) passing the sample vapor mixture from the boiling chamber to an elongated primary separation tube, the separation tube having internal sidewalls and a longitudinal axis, the longitudinal axis being angled between vertical and horizontal and thus having an upper region and a lower region; (c) collecting the physically transported liquid analyte on the internal sidewalls of the separation tube; and (d) flowing the collected analyte along the angled internal sidewalls of the separation tube to and pass the separation tube lower region. The invention also includes passing a turbulence inducing wave through a vapor mixture to separate physically transported liquid second material from vaporized first material. Apparatus is also disclosed for effecting separations. Further disclosed is a fluidically powered liquid test sample withdrawal apparatus for withdrawing a liquid test sample from a test sample container and for cleaning the test sample container. 8 figs.

  2. 77 FR 68732 - Notice of Intent To Request Revision and Extension of a Currently Approved Information Collection

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-16

    ... population, sampling design, and/or questionnaire length. Some of the vegetable production surveys will incorporate sampling of the total population of producers, while the processing surveys will involve a total...

  3. Adrenal activity in maned wolves is higher on farmlands and park boundaries than within protected areas.

    PubMed

    Spercoski, Katherinne M; Morais, Rosana N; Morato, Ronaldo G; de Paula, Rogério C; Azevedo, Fernanda C; May-Júnior, Joares A; Santos, Jean P; Reghelin, Angela L; Wildt, David E; Songsasen, Nucharin

    2012-11-01

    In this study we measured excreted fecal corticoid metabolites (FCM) in maned wolves (Chrysocyon brachyurus) living within a protected reserve, on farmlands or in a boundary zone between the two habitats, and determined the impacts of season and reproductive status on adrenal activity. Feces were collected within a national park (n=191 samples), a park boundary zone (n=39) and on nearby farmlands (n=27), processed and analyzed by enzyme immunoassay. FCM amounts from samples collected on farmlands were higher (P<0.05) than in those collected inside the reserve and from the boundary zone. In relation to seasonality, FCM were elevated (P<0.05) in spring (September-November) when wolf pairs were raising young. We then divided the samples collected during breeding season (March-August) into cycling females and male/non-cycling females based on fecal progesterone: fecal testosterone ratio. FCM concentrations of the former collected inside the park were higher than (P<0.05) than the latter group. However, there were no differences in FCM levels between the two groups for samples collected in the boundary zone and on farmlands. Furthermore, FCM concentrations of male/non-cycling females samples collected on farmlands were 2- to 5-fold higher (P<0.05) than in counterparts collected inside the park. The consistently high FCM concentrations in samples collected on farmlands indicate that, in addition to seasonality, gender and reproductive status, anthropogenic pressures also contribute to elevating adrenal steroid for individuals living in altered habitat. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Some thoughts on problems associated with various sampling media used for environmental monitoring

    USGS Publications Warehouse

    Horowitz, A.J.

    1997-01-01

    Modern analytical instrumentation is capable of measuring a variety of trace elements at concentrations down into the single or double digit parts-per-trillion (ng l-1) range. This holds for the three most common sample media currently used in environmental monitoring programs: filtered water, whole-water and separated suspended sediment. Unfortunately, current analytical capabilities have exceeded the current capacity to collect both uncontaminated and representative environmental samples. The success of any trace element monitoring program requires that this issue be both understood and addressed. The environmental monitoring of trace elements requires the collection of calendar- and event-based dissolved and suspended sediment samples. There are unique problems associated with the collection and chemical analyses of both types of sample media. Over the past 10 years, reported ambient dissolved trace element concentrations have declined. Generally, these decreases do not reflect better water quality, but rather improvements in the procedures used to collect, process, preserve and analyze these samples without contaminating them during these steps. Further, recent studies have shown that the currently accepted operational definition of dissolved constituents (material passing a 0.45 ??m membrane filter) is inadequat owing to sampling and processing artifacts. The existence of these artifacts raises questions about the generation of accurate, precise and comparable 'dissolved' trace element data. Suspended sediment and associated trace elements can display marked short- and long-term spatial and temporal variability. This implies that spatially representative samples only can be obtained by generating composites using depth- and width-integrated sampling techniques. Additionally, temporal variations have led to the view that the determination of annual trace element fluxes may require nearly constant (e.g., high-frequency) sampling and subsequent chemical analyses. Ultimately, sampling frequency for flux estimates becomes dependent on the time period of concern (daily, weekly, monthly, yearly) and the amount of acceptable error associated with these estimates.

  5. The Astromaterials X-Ray Computed Tomography Laboratory at Johnson Space Center

    NASA Technical Reports Server (NTRS)

    Zeigler, R. A.; Coleff, D. M.; McCubbin, F. M.

    2017-01-01

    The Astromaterials Acquisition and Curation Office at NASA's Johnson Space Center (hereafter JSC curation) is the past, present, and future home of all of NASA's astromaterials sample collections. JSC curation currently houses all or part of nine different sample collections: (1) Apollo samples (1969), (2) Lunar samples (1972), (3) Antarctic meteorites (1976), (4) Cosmic Dust particles (1981), (5) Microparticle Impact Collection (1985), (6) Genesis solar wind atoms (2004); (7) Stardust comet Wild-2 particles (2006), (8) Stardust interstellar particles (2006), and (9) Hayabusa asteroid Itokawa particles (2010). Each sample collection is housed in a dedicated clean room, or suite of clean rooms, that is tailored to the requirements of that sample collection. Our primary goals are to maintain the long-term integrity of the samples and ensure that the samples are distributed for scientific study in a fair, timely, and responsible manner, thus maximizing the return on each sample. Part of the curation process is planning for the future, and we also perform fundamental research in advanced curation initiatives. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of sample collections, or getting new results from existing sample collections [2]. We are (and have been) planning for future curation, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, and curation of organically- and biologically-sensitive samples. As part of these advanced curation efforts we are augmenting our analytical facilities as well. A micro X-Ray computed tomography (micro-XCT) laboratory dedicated to the study of astromaterials will be coming online this spring within the JSC Curation office, and we plan to add additional facilities that will enable nondestructive (or minimally-destructive) analyses of astromaterials in the near future (micro-XRF, confocal imaging Raman Spectroscopy). These facilities will be available to: (1) develop sample handling and storage techniques for future sample return missions; (2) be utilized by PET for future sample return missions; (3) be used for retroactive PET (Positron Emission Tomography)-style analyses of our existing collections; and (4) for periodic assessments of the existing sample collections. Here we describe the new micro-XCT system, as well as some of the ongoing or anticipated applications of the instrument.

  6. Curating NASA's Past, Present, and Future Astromaterial Sample Collections

    NASA Technical Reports Server (NTRS)

    Zeigler, R. A.; Allton, J. H.; Evans, C. A.; Fries, M. D.; McCubbin, F. M.; Nakamura-Messenger, K.; Righter, K.; Zolensky, M.; Stansbery, E. K.

    2016-01-01

    The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC curation) is responsible for curating all of NASA's extraterrestrial samples. JSC presently curates 9 different astromaterials collections in seven different clean-room suites: (1) Apollo Samples (ISO (International Standards Organization) class 6 + 7); (2) Antarctic Meteorites (ISO 6 + 7); (3) Cosmic Dust Particles (ISO 5); (4) Microparticle Impact Collection (ISO 7; formerly called Space-Exposed Hardware); (5) Genesis Solar Wind Atoms (ISO 4); (6) Stardust Comet Particles (ISO 5); (7) Stardust Interstellar Particles (ISO 5); (8) Hayabusa Asteroid Particles (ISO 5); (9) OSIRIS-REx Spacecraft Coupons and Witness Plates (ISO 7). Additional cleanrooms are currently being planned to house samples from two new collections, Hayabusa 2 (2021) and OSIRIS-REx (2023). In addition to the labs that house the samples, we maintain a wide variety of infra-structure facilities required to support the clean rooms: HEPA-filtered air-handling systems, ultrapure dry gaseous nitrogen systems, an ultrapure water system, and cleaning facilities to provide clean tools and equipment for the labs. We also have sample preparation facilities for making thin sections, microtome sections, and even focused ion-beam sections. We routinely monitor the cleanliness of our clean rooms and infrastructure systems, including measurements of inorganic or organic contamination, weekly airborne particle counts, compositional and isotopic monitoring of liquid N2 deliveries, and daily UPW system monitoring. In addition to the physical maintenance of the samples, we track within our databases the current and ever changing characteristics (weight, location, etc.) of more than 250,000 individually numbered samples across our various collections, as well as more than 100,000 images, and countless "analog" records that record the sample processing records of each individual sample. JSC Curation is co-located with JSC's Astromaterials Research Office, which houses a world-class suite of analytical instrumentation and scientists. We leverage these labs and personnel to better curate the samples. Part of the cu-ration process is planning for the future, and we refer to these planning efforts as "advanced curation". Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of collections as envi-sioned by NASA exploration goals. We are (and have been) planning for future cu-ration, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, and curation of organically- and biologically-sensitive samples.

  7. Operation of a sampling train for the analysis of environmental species in coal gasification gas-phase process streams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pochan, M.J.; Massey, M.J.

    1979-02-01

    This report discusses the results of actual raw product gas sampling efforts and includes: Rationale for raw product gas sampling efforts; design and operation of the CMU gas sampling train; development and analysis of a sampling train data base; and conclusions and future application of results. The results of sampling activities at the CO/sub 2/-Acceptor and Hygas pilot plants proved that: The CMU gas sampling train is a valid instrument for characterization of environmental parameters in coal gasification gas-phase process streams; depending on the particular process configuration, the CMU gas sampling train can reduce gasifier effluent characterization activity to amore » single location in the raw product gas line; and in contrast to the slower operation of the EPA SASS Train, CMU's gas sampling train can collect representative effluent data at a rapid rate (approx. 2 points per hour) consistent with the rate of change of process variables, and thus function as a tool for process engineering-oriented analysis of environmental characteristics.« less

  8. A chemodynamic approach for estimating losses of target organic chemicals from water during sample holding time

    USGS Publications Warehouse

    Capel, P.D.; Larson, S.J.

    1995-01-01

    Minimizing the loss of target organic chemicals from environmental water samples between the time of sample collection and isolation is important to the integrity of an investigation. During this sample holding time, there is a potential for analyte loss through volatilization from the water to the headspace, sorption to the walls and cap of the sample bottle; and transformation through biotic and/or abiotic reactions. This paper presents a chemodynamic-based, generalized approach to estimate the most probable loss processes for individual target organic chemicals. The basic premise is that the investigator must know which loss process(es) are important for a particular analyte, based on its chemodynamic properties, when choosing the appropriate method(s) to prevent loss.

  9. Biomonitoring of Environmental Status and Trends (BEST) Program: Field Procedures for Assessing the Exposure of Fish to Environmental Contaminants

    USGS Publications Warehouse

    Schmitt, Christopher J.; Blazer, Vicki; Dethloff, Gail M.; Tillitt, Donald E.; Gross, Timothy S.; Bryant, Wade L.; DeWeese, L. Rod; Smith, Stephen B.; Goede, Ronald W.; Bartish, Timothy M.; Kubiak, Timothy J.

    1999-01-01

    This document describes procedures used to collect information, tissues, and fluids for documenting the exposure of fish to environmental contaminants. For the procedures described here, fish are captured (preferably by electrofishing) and held alive until processing (generally <1 h). Fish are weighed, measured, and examined for grossly visible external lesions and pathologies. A blood sample is collected by caudal veinipuncture using a needle and syringe. The fish is subdued and it's abdominal cavity opened. The internal organs are dissected from the fish for examination. The sex of the fish is determined by direct observation of its gonads. The liver is weighed (most species) and cut into small cubes and flash-frozen in cryogenic vials, which are stored and shipped in dry ice or liquid nitrogen. Additional liver cubes plus all grossly visible anomalies are preserved for histopathology. The gonads and spleen are weighed, and samples are preserved for histopathology. The kidneys are examined, and histopathology samples collected. A gill sample is also collected and preserved. All remaining tissues are returned to the carcass, which is wrapped in foil, labeled for chemical analysis, and chilled. Individual fish carcasses are composited by station, species, and gender; frozen; and shipped to the analytical laboratory. Procedures are also described for record keeping; processing blood to obtain serum and plasma; flash-freezing samples; cleaning equipment; and preventing the transport of living organisms among waterways. A list of necessary equipment and supplies is also provided.

  10. After site selection and before data analysis: sampling, sorting, and laboratory procedures used in stream benthic macroinvertebrate monitoring programs by USA state agencies

    USGS Publications Warehouse

    Carter, James L.; Resh, Vincent H.

    2001-01-01

    A survey of methods used by US state agencies for collecting and processing benthic macroinvertebrate samples from streams was conducted by questionnaire; 90 responses were received and used to describe trends in methods. The responses represented an estimated 13,000-15,000 samples collected and processed per year. Kicknet devices were used in 64.5% of the methods; other sampling devices included fixed-area samplers (Surber and Hess), artificial substrates (Hester-Dendy and rock baskets), grabs, and dipnets. Regional differences existed, e.g., the 1-m kicknet was used more often in the eastern US than in the western US. Mesh sizes varied among programs but 80.2% of the methods used a mesh size between 500 and 600 (mu or u)m. Mesh size variations within US Environmental Protection Agency regions were large, with size differences ranging from 100 to 700 (mu or u)m. Most samples collected were composites; the mean area sampled was 1.7 m2. Samples rarely were collected using a random method (4.7%); most samples (70.6%) were collected using "expert opinion", which may make data obtained operator-specific. Only 26.3% of the methods sorted all the organisms from a sample; the remainder subsampled in the laboratory. The most common method of subsampling was to remove 100 organisms (range = 100-550). The magnification used for sorting ranged from 1 (sorting by eye) to 30x, which results in inconsistent separation of macroinvertebrates from detritus. In addition to subsampling, 53% of the methods sorted large/rare organisms from a sample. The taxonomic level used for identifying organisms varied among taxa; Ephemeroptera, Plecoptera, and Trichoptera were generally identified to a finer taxonomic resolution (genus and species) than other taxa. Because there currently exists a large range of field and laboratory methods used by state programs, calibration among all programs to increase data comparability would be exceptionally challenging. However, because many techniques are shared among methods, limited testing could be designed to evaluate whether procedural differences affect the ability to determine levels of environmental impairment using benthic macroinvertebrate communities.

  11. Introduction to Field Water-Quality Methods for the Collection of Metals - 2007 Project Summary

    USGS Publications Warehouse

    Allen, Monica L.

    2008-01-01

    The U.S. Geological Survey (USGS), Region VI of the U.S. Environmental Protection Agency (USEPA), and the Osage Nation presented three 3-day workshops, in June-August 2007, entitled ?Introduction to Field Water-Quality Methods for the Collection of Metals.? The purpose of the workshops was to provide instruction to tribes within USEPA Region VI on various USGS surface-water measurement methods and water-quality sampling protocols for the collection of surface-water samples for metals analysis. Workshop attendees included members from over 22 tribes and pueblos. USGS instructors came from Oklahoma, New Mexico, and Georgia. Workshops were held in eastern and south-central Oklahoma and New Mexico and covered many topics including presampling preparation, water-quality monitors, and sampling for metals in surface water. Attendees spent one full classroom day learning the field methods used by the USGS Water Resources Discipline and learning about the complexity of obtaining valid water-quality and quality-assurance data. Lectures included (1) a description of metal contamination sources in surface water; (2) introduction on how to select field sites, equipment, and laboratories for sample analysis; (3) collection of sediment in surface water; and (4) utilization of proper protocol and methodology for sampling metals in surface water. Attendees also were provided USGS sampling equipment for use during the field portion of the class so they had actual ?hands-on? experience to take back to their own organizations. The final 2 days of the workshop consisted of field demonstrations of current USGS water-quality sample-collection methods. The hands-on training ensured that attendees were exposed to and experienced proper sampling procedures. Attendees learned integrated-flow techniques during sample collection, field-property documentation, and discharge measurements and calculations. They also used enclosed chambers for sample processing and collected quality-assurance samples to verify their techniques. Benefits of integrated water-quality sample-collection methods are varied. Tribal environmental programs now have the ability to collect data that are comparable across watersheds. The use of consistent sample collection, manipulation, and storage techniques will provide consistent quality data that will enhance the understanding of local water resources. The improved data quality also will help the USEPA better document the condition of the region?s water. Ultimately, these workshops equipped tribes to use uniform sampling methods and to provide consistent quality data that are comparable across the region.

  12. Using Language Sample Analysis to Assess Spoken Language Production in Adolescents

    ERIC Educational Resources Information Center

    Miller, Jon F.; Andriacchi, Karen; Nockerts, Ann

    2016-01-01

    Purpose: This tutorial discusses the importance of language sample analysis and how Systematic Analysis of Language Transcripts (SALT) software can be used to simplify the process and effectively assess the spoken language production of adolescents. Method: Over the past 30 years, thousands of language samples have been collected from typical…

  13. A Synopsis of Technical Issues for Monitoring Sediment in Highway and Urban Runoff

    USGS Publications Warehouse

    Bent, Gardner C.; Gray, John R.; Smith, Kirk P.; Glysson, G. Douglas

    2000-01-01

    Accurate and representative sediment data are critical for assessing the potential effects of highway and urban runoff on receiving waters. The U.S. Environmental Protection Agency identified sediment as the most widespread pollutant in the Nation's rivers and streams, affecting aquatic habitat, drinking water treatment processes, and recreational uses of rivers, lakes, and estuaries. Representative sediment data are also necessary for quantifying and interpreting concentrations, loads, and effects of trace elements and organic constituents associated with highway and urban runoff. Many technical issues associated with the collecting, processing, and analyzing of samples must be addressed to produce valid (useful for intended purposes), current, complete, and technically defensible data for local, regional, and national information needs. All aspects of sediment data-collection programs need to be evaluated, and adequate quality-control data must be collected and documented so that the comparability and representativeness of data obtained for highway- and urban-runoff studies may be assessed. Collection of representative samples for the measurement of sediment in highway and urban runoff involves a number of interrelated issues. Temporal and spatial variability in runoff result from a combination of factors, including volume and intensity of precipitation, rate of snowmelt, and features of the drainage basin such as area, slope, infiltration capacity, channel roughness, and storage characteristics. In small drainage basins such as those found in many highway and urban settings, automatic samplers are often the most suitable method for collecting samples of runoff for a variety of reasons. Indirect sediment-measurement methods are also useful as supplementary and(or) surrogate means for monitoring sediment in runoff. All of these methods have limitations in addition to benefits, which must be identified and quantified to produce representative data. Methods for processing raw sediment samples (including homogenization and subsampling) for subsequent analysis for total suspended solids or suspended-sediment concentration often increase variance and may introduce bias. Processing artifacts can be substantial if the methods used are not appropriate for the concentrations and particle-size distributions present in the samples collected. Analytical methods for determining sediment concentrations include the suspended-sediment concentration and the total suspended solids methods. Although the terms suspended-sediment concentration and total suspended solids are often used interchangeably to describe the total concentration of suspended solid-phase material, the analytical methods differ and can produce substantially different results. The total suspended solids method, which commonly is used to produce highway- and urban-runoff sediment data, may not be valid for studies of runoff water quality. Studies of fluvial and highway-runoff sediment data indicate that analyses of samples by the total suspended solids method tends to under represent the true sediment concentration, and that relations between total suspended solids and suspended-sediment concentration are not transferable from site to site even when grain-size distribution information is available. Total suspended solids data used to calculate suspended-sediment loads in highways and urban runoff may be fundamentally unreliable. Consequently, use of total suspended solids data may have adverse consequences for the assessment, design, and maintenance of sediment-removal best management practices. Therefore, it may be necessary to analyze water samples using the suspended-sediment concentration method. Data quality, comparability, and utility are important considerations in collection, processing, and analysis of sediment samples and interpretation of sediment data for highway- and urban-runoff studies. Results from sediment studies must be comparable and readily transf

  14. AR-NE3A, a New Macromolecular Crystallography Beamline for Pharmaceutical Applications at the Photon Factory

    NASA Astrophysics Data System (ADS)

    Yamada, Yusuke; Hiraki, Masahiko; Sasajima, Kumiko; Matsugaki, Naohiro; Igarashi, Noriyuki; Amano, Yasushi; Warizaya, Masaichi; Sakashita, Hitoshi; Kikuchi, Takashi; Mori, Takeharu; Toyoshima, Akio; Kishimoto, Shunji; Wakatsuki, Soichi

    2010-06-01

    Recent advances in high-throughput techniques for macromolecular crystallography have highlighted the importance of structure-based drug design (SBDD), and the demand for synchrotron use by pharmaceutical researchers has increased. Thus, in collaboration with Astellas Pharma Inc., we have constructed a new high-throughput macromolecular crystallography beamline, AR-NE3A, which is dedicated to SBDD. At AR-NE3A, a photon flux up to three times higher than those at existing high-throughput beams at the Photon Factory, AR-NW12A and BL-5A, can be realized at the same sample positions. Installed in the experimental hutch are a high-precision diffractometer, fast-readout, high-gain CCD detector, and sample exchange robot capable of handling more than two hundred cryo-cooled samples stored in a Dewar. To facilitate high-throughput data collection required for pharmaceutical research, fully automated data collection and processing systems have been developed. Thus, sample exchange, centering, data collection, and data processing are automatically carried out based on the user's pre-defined schedule. Although Astellas Pharma Inc. has a priority access to AR-NE3A, the remaining beam time is allocated to general academic and other industrial users.

  15. Detection and Characterization of Circulating Tumour Cells from Frozen Peripheral Blood Mononuclear Cells

    PubMed Central

    Lu, David; Graf, Ryon P.; Harvey, Melissa; Madan, Ravi A.; Heery, Christopher; Marte, Jennifer; Beasley, Sharon; Tsang, Kwong Y.; Krupa, Rachel; Louw, Jessica; Wahl, Justin; Bales, Natalee; Landers, Mark; Marrinucci, Dena; Schlom, Jeffrey; Gulley, James L.; Dittamore, Ryan

    2015-01-01

    Retrospective analysis of patient tumour samples is a cornerstone of clinical research. CTC biomarker characterization offers a non-invasive method to analyse patient samples. However, current CTC technologies require prospective blood collection, thereby reducing the ability to utilize archived clinical cohorts with long-term outcome data. We sought to investigate CTC recovery from frozen, archived patient PBMC pellets. Matched samples from both mCRPC patients and mock samples, which were prepared by spiking healthy donor blood with cultured prostate cancer cell line cells, were processed “fresh” via Epic CTC Platform or from “frozen” PBMC pellets. Samples were analysed for CTC enumeration and biomarker characterization via immunofluorescent (IF) biomarkers, fluorescence in-situ hybridization (FISH) and CTC morphology. In the frozen patient PMBC samples, the median CTC recovery was 18%, compared to the freshly processed blood. However, abundance and localization of cytokeratin (CK) and androgen receptor (AR) protein, as measured by IF, were largely concordant between the fresh and frozen CTCs. Furthermore, a FISH analysis of PTEN loss showed high concordance in fresh vs. frozen. The observed data indicate that CTC biomarker characterization from frozen archival samples is feasible and representative of prospectively collected samples. PMID:28936240

  16. Stability and reproducibility of proteomic profiles measured with an aptamer-based platform.

    PubMed

    Kim, Claire H; Tworoger, Shelley S; Stampfer, Meir J; Dillon, Simon T; Gu, Xuesong; Sawyer, Sherilyn J; Chan, Andrew T; Libermann, Towia A; Eliassen, A Heather

    2018-05-30

    The feasibility of SOMAscan, a multiplex, high sensitivity proteomics platform, for use in studies using archived plasma samples has not yet been assessed. We quantified 1,305 proteins from plasma samples donated by 16 Nurses' Health Study (NHS) participants, 40 NHSII participants, and 12 local volunteers. We assessed assay reproducibility using coefficients of variation (CV) from duplicate samples and intra-class correlation coefficients (ICC) and Spearman correlation coefficients (r) of samples processed (i.e., centrifuged and aliquoted into separate components) immediately, 24, and 48 hours after collection, as well as those of samples collected from the same individuals 1 year apart. CVs were <20% for 99% of proteins overall and <10% for 92% of proteins in heparin samples compared to 66% for EDTA samples. We observed ICC or Spearman r (comparing immediate vs. 24-hour delayed processing) ≥0.75 for 61% of proteins, with some variation by anticoagulant (56% for heparin and 70% for EDTA) and protein class (ranging from 49% among kinases to 83% among hormones). Within-person stability over 1 year was good (ICC or Spearman r ≥ 0.4) for 91% of proteins. These results demonstrate the feasibility of SOMAscan for analyses of archived plasma samples.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alan W. Scaroni; David C. Glick

    This project generated and provided coal samples and accompanying analytical data for research by DOE contractors and others. The five-year contract and a six-month no-cost extension have been completed. The Final Technical Progress Report is being prepared. All activities specified under the five-year contract and its six-month no-cost extension have been completed. Eleven DECS samples were collected, processed to a variety of particle sizes, heat-sealed in foil laminate bags under argon, and placed in refrigerated storage. All were analyzed for basic chemical composition, inorganic major and trace element composition including hazardous air pollutant elements, petrographic composition and characteristics, thermoplastic behaviormore » (if applicable), and other properties relevant to commercial utilization. Most were also analyzed by NMR, py/gc/ms, and a standardized liquefaction test; trends and relationships observed were evaluated and summarized. Twenty-two DECS samples collected under the previous contract received further processing, and most of these were subjected to organic geochemical and standardized liquefaction tests as well. Selected DECS samples were monitored annually to evaluate the effectiveness of foil laminate bags for long-term sample storage. Twenty-three PSOC samples collected under previous contracts and purged with argon before storage were also maintained and distributed, for a total of 56 samples covered by the contract. During the contract, 804 samples in 1586 containers, 2109 data printouts, and individual data items from 34208 samples were distributed. In the subject quarter, 25 samples, 18 data printouts, and individual data items from 1374 samples were distributed. All DECS samples are now available for immediate distribution at minus 6 mm (-1/4 inch), minus 0.85 mm (-20 mesh U.S.), and minus 0.25 mm (-60 mesh U.S.).« less

  18. Identification and Mitigation of Generated Solid By-Products during Advanced Electrode Materials Processing

    DOE PAGES

    Tsai, Candace S. J.; Dysart, Arthur D.; Beltz, Jay H.; ...

    2015-12-30

    A scalable, solid-state elevated temperature process was developed to produce high capacity carbonaceous electrode materials for energy storage devices via decomposition of starch-based precursor in an inert atmosphere. The fabricated carbon-based architectures are useful as an excellent electrode material for lithium-ion, sodium-ion and lithium-sulfur batteries. This article focuses on the study and analysis of the formed nanometer-sized byproducts during the lab-scale production of carbonaceous electrode materials in the process design phase. The complete material production process was studied by operation, namely during heating, holding the reaction at elevated temperature, followed by cooling. The unknown downstream particles in the process exhaustmore » were collected and characterized via aerosol and liquid suspensions, and they were quantified using direct-reading instruments for number and mass concentrations. The airborne emissions were collected on polycarbonate filters and TEM grids using the Tsai diffusion sampler (TDS) for characterization and further analysis. Released byproduct aerosols collected in a deionized (DI) water trap were analyzed using a Nanosight real time nanoparticle characterization system and the aerosols emitted post water suspension were collected and characterized. Individual particles in the nanometer size range were found in exhaust aerosols, however, crystal structured aggregates were formed on the sampling substrate after a long-term sampling of emitted exhaust. After characterizing the released aerosol byproducts, methods were also identified to mitigate possible human and environmental exposures upon the industrial implementation of such a process.« less

  19. Textural Analysis and Substrate Classification in the Nearshore Region of Lake Superior Using High-Resolution Multibeam Bathymetry

    NASA Astrophysics Data System (ADS)

    Dennison, Andrew G.

    Classification of the seafloor substrate can be done with a variety of methods. These methods include Visual (dives, drop cameras); mechanical (cores, grab samples); acoustic (statistical analysis of echosounder returns). Acoustic methods offer a more powerful and efficient means of collecting useful information about the bottom type. Due to the nature of an acoustic survey, larger areas can be sampled, and by combining the collected data with visual and mechanical survey methods provide greater confidence in the classification of a mapped region. During a multibeam sonar survey, both bathymetric and backscatter data is collected. It is well documented that the statistical characteristic of a sonar backscatter mosaic is dependent on bottom type. While classifying the bottom-type on the basis on backscatter alone can accurately predict and map bottom-type, i.e a muddy area from a rocky area, it lacks the ability to resolve and capture fine textural details, an important factor in many habitat mapping studies. Statistical processing of high-resolution multibeam data can capture the pertinent details about the bottom-type that are rich in textural information. Further multivariate statistical processing can then isolate characteristic features, and provide the basis for an accurate classification scheme. The development of a new classification method is described here. It is based upon the analysis of textural features in conjunction with ground truth sampling. The processing and classification result of two geologically distinct areas in nearshore regions of Lake Superior; off the Lester River,MN and Amnicon River, WI are presented here, using the Minnesota Supercomputer Institute's Mesabi computing cluster for initial processing. Processed data is then calibrated using ground truth samples to conduct an accuracy assessment of the surveyed areas. From analysis of high-resolution bathymetry data collected at both survey sites is was possible to successfully calculate a series of measures that describe textural information about the lake floor. Further processing suggests that the features calculated capture a significant amount of statistical information about the lake floor terrain as well. Two sources of error, an anomalous heave and refraction error significantly deteriorated the quality of the processed data and resulting validate results. Ground truth samples used to validate the classification methods utilized for both survey sites, however, resulted in accuracy values ranging from 5 -30 percent at the Amnicon River, and between 60-70 percent for the Lester River. The final results suggest that this new processing methodology does adequately capture textural information about the lake floor and does provide an acceptable classification in the absence of significant data quality issues.

  20. Integration of DNA sample collection into a multi-site birth defects case-control study.

    PubMed

    Rasmussen, Sonja A; Lammer, Edward J; Shaw, Gary M; Finnell, Richard H; McGehee, Robert E; Gallagher, Margaret; Romitti, Paul A; Murray, Jeffrey C

    2002-10-01

    Advances in quantitative analysis and molecular genotyping have provided unprecedented opportunities to add biological sampling and genetic information to epidemiologic studies. The purpose of this article is to describe the incorporation of DNA sample collection into the National Birth Defects Prevention Study (NBDPS), an ongoing case-control study in an eight-state consortium with a primary goal to identify risk factors for birth defects. Babies with birth defects are identified through birth defects surveillance systems in the eight participating centers. Cases are infants with one or more of over 30 major birth defects. Controls are infants without defects from the same geographic area. Epidemiologic information is collected through an hour-long interview with mothers of both cases and controls. We added the collection of buccal cytobrush DNA samples for case-infants, control-infants, and their parents to this study. We describe here the methods by which the samples have been collected and processed, establishment of a centralized resource for DNA banking, and quality control, database management, access, informed consent, and confidentiality issues. Biological sampling and genetic analyses are important components to epidemiologic studies of birth defects aimed at identifying risk factors. The DNA specimens collected in this study can be used for detection of mutations, study of polymorphic variants that confer differential susceptibility to teratogens, and examination of interactions among genetic risk factors. Information on the methods used and issues faced by the NBDPS may be of value to others considering the addition of DNA sampling to epidemiologic studies.

  1. Optimization of HPV DNA detection in urine by improving collection, storage, and extraction.

    PubMed

    Vorsters, A; Van den Bergh, J; Micalessi, I; Biesmans, S; Bogers, J; Hens, A; De Coster, I; Ieven, M; Van Damme, P

    2014-11-01

    The benefits of using urine for the detection of human papillomavirus (HPV) DNA have been evaluated in disease surveillance, epidemiological studies, and screening for cervical cancers in specific subgroups. HPV DNA testing in urine is being considered for important purposes, notably the monitoring of HPV vaccination in adolescent girls and young women who do not wish to have a vaginal examination. The need to optimize and standardize sampling, storage, and processing has been reported.In this paper, we examined the impact of a DNA-conservation buffer, the extraction method, and urine sampling on the detection of HPV DNA and human DNA in urine provided by 44 women with a cytologically normal but HPV DNA-positive cervical sample. Ten women provided first-void and midstream urine samples. DNA analysis was performed using real-time PCR to allow quantification of HPV and human DNA.The results showed that an optimized method for HPV DNA detection in urine should (a) prevent DNA degradation during extraction and storage, (b) recover cell-free HPV DNA in addition to cell-associated DNA, (c) process a sufficient volume of urine, and (d) use a first-void sample.In addition, we found that detectable human DNA in urine may not be a good internal control for sample validity. HPV prevalence data that are based on urine samples collected, stored, and/or processed under suboptimal conditions may underestimate infection rates.

  2. Adaptive Sampling of Time Series During Remote Exploration

    NASA Technical Reports Server (NTRS)

    Thompson, David R.

    2012-01-01

    This work deals with the challenge of online adaptive data collection in a time series. A remote sensor or explorer agent adapts its rate of data collection in order to track anomalous events while obeying constraints on time and power. This problem is challenging because the agent has limited visibility (all its datapoints lie in the past) and limited control (it can only decide when to collect its next datapoint). This problem is treated from an information-theoretic perspective, fitting a probabilistic model to collected data and optimizing the future sampling strategy to maximize information gain. The performance characteristics of stationary and nonstationary Gaussian process models are compared. Self-throttling sensors could benefit environmental sensor networks and monitoring as well as robotic exploration. Explorer agents can improve performance by adjusting their data collection rate, preserving scarce power or bandwidth resources during uninteresting times while fully covering anomalous events of interest. For example, a remote earthquake sensor could conserve power by limiting its measurements during normal conditions and increasing its cadence during rare earthquake events. A similar capability could improve sensor platforms traversing a fixed trajectory, such as an exploration rover transect or a deep space flyby. These agents can adapt observation times to improve sample coverage during moments of rapid change. An adaptive sampling approach couples sensor autonomy, instrument interpretation, and sampling. The challenge is addressed as an active learning problem, which already has extensive theoretical treatment in the statistics and machine learning literature. A statistical Gaussian process (GP) model is employed to guide sample decisions that maximize information gain. Nonsta tion - ary (e.g., time-varying) covariance relationships permit the system to represent and track local anomalies, in contrast with current GP approaches. Most common GP models are stationary, e.g., the covariance relationships are time-invariant. In such cases, information gain is independent of previously collected data, and the optimal solution can always be computed in advance. Information-optimal sampling of a stationary GP time series thus reduces to even spacing, and such models are not appropriate for tracking localized anomalies. Additionally, GP model inference can be computationally expensive.

  3. Data Validation Package April 2016 Groundwater and Surface Water Sampling at the Monticello, Utah, Disposal and Processing Sites August 2016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nguyen, Jason; Smith, Fred

    This semiannual event includes sampling groundwater and surface water at the Monticello Disposal and Processing Sites. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated) and Program Directive MNT-2016-01. Complete sample sets were collected from 42 of 48 planned locations (9 of 9 former mill site wells, 13 of 13 downgradient wells, 7 of 9 downgradient permeable reactive barrier wells, 4 of 7 seeps and wetlands, and 9 of 10 surface water locations). Planned monitoring locations are shown in Attachment 1, Sampling andmore » Analysis Work Order. Locations R6-M3, SW00-01, Seep 1, Seep 2, and Seep 5 were not sampled due to insufficient water availability. A partial sample was collected at location R4-M3 due to insufficient water. All samples from the permeable reactive barrier wells were filtered as specified in the program directive. Duplicate samples were collected from surface water location Sorenson and from monitoring wells 92-07 and RlO-Ml. Water levels were measured at all sampled wells and an additional set of wells. See Attachment2, Trip Report for additional details. The contaminants of concern (COCs) for the Monticello sites are arsenic, manganese, molybdenum, nitrate+ nitrite as nitrogen (nitrate+ nitrite as N), selenium, uranium, and vanadium. Locations with COCs that exceeded remediation goals are listed in Table 1 and Table 2. Time-concentration graphs of the COCs for all groundwater and surface water locations are included in Attachment 3, Data Presentation. An assessment of anomalous data is included in Attachment 4.« less

  4. Bed-material characteristics of the Sacramento–San Joaquin Delta, California, 2010–13

    USGS Publications Warehouse

    Marineau, Mathieu D.; Wright, Scott A.

    2017-02-10

    The characteristics of bed material at selected sites within the Sacramento–San Joaquin Delta, California, during 2010–13 are described in a study conducted by the U.S. Geological Survey in cooperation with the Bureau of Reclamation. During 2010‒13, six complete sets of samples were collected. Samples were initially collected at 30 sites; however, starting in 2012, samples were collected at 7 additional sites. These sites are generally collocated with an active streamgage. At all but one site, a separate bed-material sample was collected at three locations within the channel (left, right, and center). Bed-material samples were collected using either a US BMH–60 or a US BM–54 (for sites with higher stream velocity) cable-suspended, scoop sampler. Samples from each location were oven-dried and sieved. Bed material finer than 2 millimeters was subsampled using a sieving riffler and processed using a Beckman Coulter LS 13–320 laser diffraction particle-size analyzer. To determine the organic content of the bed material, the loss on ignition method was used for one subsample from each location. Particle-size distributions are presented as cumulative percent finer than a given size. Median and 90th-percentile particle size, and the percentage of subsample mass lost using the loss on ignition method for each sample are also presented in this report.

  5. Digital Curation of Earth Science Samples Starts in the Field

    NASA Astrophysics Data System (ADS)

    Lehnert, K. A.; Hsu, L.; Song, L.; Carter, M. R.

    2014-12-01

    Collection of physical samples in the field is an essential part of research in the Earth Sciences. Samples provide a basis for progress across many disciplines, from the study of global climate change now and over the Earth's history, to present and past biogeochemical cycles, to magmatic processes and mantle dynamics. The types of samples, methods of collection, and scope and scale of sampling campaigns are highly diverse, ranging from large-scale programs to drill rock and sediment cores on land, in lakes, and in the ocean, to environmental observation networks with continuous sampling, to single investigator or small team expeditions to remote areas around the globe or trips to local outcrops. Cyberinfrastructure for sample-related fieldwork needs to cater to the different needs of these diverse sampling activities, aligning with specific workflows, regional constraints such as connectivity or climate, and processing of samples. In general, digital tools should assist with capture and management of metadata about the sampling process (location, time, method) and the sample itself (type, dimension, context, images, etc.), management of the physical objects (e.g., sample labels with QR codes), and the seamless transfer of sample metadata to data systems and software relevant to the post-sampling data acquisition, data processing, and sample curation. In order to optimize CI capabilities for samples, tools and workflows need to adopt community-based standards and best practices for sample metadata, classification, identification and registration. This presentation will provide an overview and updates of several ongoing efforts that are relevant to the development of standards for digital sample management: the ODM2 project that has generated an information model for spatially-discrete, feature-based earth observations resulting from in-situ sensors and environmental samples, aligned with OGC's Observation & Measurements model (Horsburgh et al, AGU FM 2014); implementation of the IGSN (International Geo Sample Number) as a globally unique sample identifier via a distributed system of allocating agents and a central registry; and the EarthCube Research Coordination Network iSamplES (Internet of Samples in the Earth Sciences) that aims to improve sharing and curation of samples through the use of CI.

  6. Effects of anticoagulant, processing delay, and assay method (branched DNA versus reverse transcriptase PCR) on measurement of human immunodeficiency virus type 1 RNA levels in plasma.

    PubMed

    Kirstein, L M; Mellors, J W; Rinaldo, C R; Margolick, J B; Giorgi, J V; Phair, J P; Dietz, E; Gupta, P; Sherlock, C H; Hogg, R; Montaner, J S; Muñoz, A

    1999-08-01

    We conducted two studies to determine the potential influence of delays in blood processing, type of anticoagulant, and assay method on human immunodeficiency virus type 1 (HIV-1) RNA levels in plasma. The first was an experimental study in which heparin- and EDTA-anticoagulated blood samples were collected from 101 HIV-positive individuals and processed to plasma after delays of 2, 6, and 18 h. HIV-1 RNA levels in each sample were then measured by both branched-DNA (bDNA) and reverse transcriptase PCR (RT-PCR) assays. Compared to samples processed within 2 h, the loss (decay) of HIV-1 RNA in heparinized blood was significant (P < 0.05) but small after 6 h (bDNA assay, -0.12 log(10) copies/ml; RT-PCR, -0.05 log(10) copies/ml) and after 18 h (bDNA assay, -0.27 log(10) copies/ml; RT-PCR, -0.15 log(10) copies/ml). Decay in EDTA-anticoagulated blood was not significant after 6 h (bDNA assay, -0.002 log(10) copies/ml; RT-PCR, -0.02 log(10) copies/ml), but it was after 18 h (bDNA assay, -0.09 log(10) copies/ml; RT-PCR, -0.09 log(10) copies/ml). Only 4% of samples processed after 6 h lost more than 50% (>/=0.3 log(10) copies/ml) of the HIV-1 RNA, regardless of the anticoagulant or the assay that was used. The second study compared HIV-1 RNA levels in samples from the Multicenter AIDS Cohort Study (MACS; samples were collected in heparin-containing tubes in 1985, had a 6-h average processing delay, and were assayed by bDNA assay) and the British Columbia Drug Treatment Program (BCDTP) (collected in EDTA- or acid citrate dextrose-containing tubes in 1996 and 1997, had a 2-h maximum processing delay, and were assayed by RT-PCR). HIV-1 RNA levels in samples from the two cohorts were not significantly different after adjusting for CD4(+)-cell count and converting bDNA assay values to those corresponding to the RT-PCR results. In summary, the decay of HIV-1 RNA measured in heparinized blood after 6 h was small (-0.05 to -0.12 log(10) copies/ml), and the minor impact of this decay on HIV-1 RNA concentrations in archived plasma samples of the MACS was confirmed by the similarity of CD4(+)-cell counts and assay-adjusted HIV-1 RNA concentrations in the MACS and BCDTP.

  7. Measurement and prediction of the size of suspended sediment over dunes

    USDA-ARS?s Scientific Manuscript database

    Knowledge of the size of sediment in suspension is important information needed for the collection of concentration data using surrogate technologies and to further understand the processes acting in the transport of suspended sediment over dunes. Samples of suspended sediment were collected at fou...

  8. Groundwater-quality and quality-control data for two monitoring wells near Pavillion, Wyoming, April and May 2012

    USGS Publications Warehouse

    Wright, Peter R.; McMahon, Peter B.; Mueller, David K.; Clark, Melanie L.

    2012-01-01

    In June 2010, the U.S. Environmental Protection Agency installed two deep monitoring wells (MW01 and MW02) near Pavillion, Wyoming, to study groundwater quality. During April and May 2012, the U.S Geological Survey, in cooperation with the Wyoming Department of Environmental Quality, collected groundwater-quality data and quality-control data from monitoring well MW01 and, following well redevelopment, quality-control data for monitoring well MW02. Two groundwater-quality samples were collected from well MW01—one sample was collected after purging about 1.5 borehole volumes, and a second sample was collected after purging 3 borehole volumes. Both samples were collected and processed using methods designed to minimize atmospheric contamination or changes to water chemistry. Groundwater-quality samples were analyzed for field water-quality properties (water temperature, pH, specific conductance, dissolved oxygen, oxidation potential); inorganic constituents including naturally occurring radioactive compounds (radon, radium-226 and radium-228); organic constituents; dissolved gasses; stable isotopes of methane, water, and dissolved inorganic carbon; and environmental tracers (carbon-14, chlorofluorocarbons, sulfur hexafluoride, tritium, helium, neon, argon, krypton, xenon, and the ratio of helium-3 to helium-4). Quality-control sample results associated with well MW01 were evaluated to determine the extent to which environmental sample analytical results were affected by bias and to evaluate the variability inherent to sample collection and laboratory analyses. Field documentation, environmental data, and quality-control data for activities that occurred at the two monitoring wells during April and May 2012 are presented.

  9. Assessment of Soil-Gas, Surface-Water, and Soil Contamination at the Installation Railhead, Fort Gordon, Georgia, 2008-2009

    USGS Publications Warehouse

    Landmeyer, James E.; Harrelson, Larry G.; Ratliff, W. Hagan; Wellborn, John B.

    2010-01-01

    The U.S. Geological Survey, in cooperation with the U.S. Department of the Army Environmental and Natural Resources Management Office of the U.S. Army Signal Center and Fort Gordon, assessed soil gas, surface water, and soil for contaminants at the Installation Railhead (IR) at Fort Gordon, Georgia, from October 2008 to September 2009. The assessment included delineation of organic contaminants present in soil-gas samples beneath the IR, and in a surface-water sample collected from an unnamed tributary to Marcum Branch in the western part of the IR. Inorganic contaminants were determined in a surface-water sample and in soil samples. This assessment was conducted to provide environmental contamination data to Fort Gordon personnel pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. Soil-gas samples collected within a localized area on the western part of the IR contained total petroleum hydrocarbons; benzene, toluene, ethylbenzene, and total xylenes (referred to as BTEX); and naphthalene above the method detection level. These soil-gas samples were collected where buildings had previously stood. Soil-gas samples collected within a localized area contained perchloroethylene (PCE). These samples were collected where buildings 2410 and 2405 had been. Chloroform and toluene were detected in a surface-water sample collected from an unnamed tributary to Marcum Branch but at concentrations below the National Primary Drinking Water Standard maximum contaminant level (MCL) for each compound. Iron was detected in the surface-water sample at 686 micrograms per liter (ug/L) and exceeded the National Secondary Drinking Water Standard MCL for iron. Metal concentrations in composite soil samples collected at three locations from land surface to a depth of 6 inches did not exceed the U.S. Environmental Protection Agency Regional Screening Levels for industrial soil.

  10. Composition and Trends of Short-Lived Trace Gases in the UT/LS over Europe Observed by the CARIBIC Aircraft

    NASA Astrophysics Data System (ADS)

    Baker, A. K.; Brenninkmeijer, C. A.; Oram, D. E.; O'Sullivan, D. A.; Slemr, F.; Schuck, T. J.

    2009-12-01

    The CARIBIC project (Civil Aircraft for the Regular Investigation of the atmosphere Based on an Instrument Container) involves the monthly deployment of an instrument container equipped to make atmospheric measurements from aboard a commercial airliner, and has operated since 2005 from aboard a Lufthansa Airbus 340-600 . Measurements from the container include in-situ trace gas and aerosol analyses and the collection of aerosol and whole air samples for post-flight laboratory analysis. Measurements made from the sampling flasks include greenhouse gas (GHG), halocarbon and nonmethane hydrocarbon (NMHC) analysis. CARIBIC flights originate in Frankfurt, Germany with routes to India, East Asia, South America, North America and Africa, and typical aircraft cruising altitudes of 10-12km allow for the monitoring of the upper troposphere/lower stratosphere (UT/LS) along these routes. Data collected during the aircraft’s departure from and return to Frankfurt provide a 4 year time series of near-monthly measurements of the composition of the UT/LS above Europe. Here we present a discussion of the composition of short-lived trace gases in the whole air samples collected above Europe during CARIBIC flights. Over 150 air samples were collected between May 2005 and July 2009, or about 4 samples per month. Of the whole air samples collected, about 45% showed influence by stratospheric air (i.e. very low values of GHG, NMHC and halocarbons, elevated O3, high potential vorticity). The remaining samples were representative of the upper troposphere; back trajectories for these samples indicate that a little over half were collected in air masses that had been in the boundary layer within the previous 8 days. The predominant source regions for these samples were the Gulf of Mexico and continental North America. Owing to their wide range of chemical lifetimes and the varying composition of emissions, short-lived trace gases transported to the UT/LS can be useful indicators of source region, photochemical processing and transport timescales of an air mass. Seasonal and longer-term trends in trace gases and trace gas composition are discussed, as well as composition of air masses having different origins. Additionally, we apply relationships between the different species, particularly the NMHC, to gain a qualitative understanding of photochemical processes occurring during transport from the boundary layer to the upper troposphere over Europe.

  11. Appropriate Handling, Processing and Analysis of Blood Samples Is Essential to Avoid Oxidation of Vitamin C to Dehydroascorbic Acid

    PubMed Central

    Pullar, Juliet M.; Carr, Anitra C.

    2018-01-01

    Vitamin C (ascorbate) is the major water-soluble antioxidant in plasma and its oxidation to dehydroascorbic acid (DHA) has been proposed as a marker of oxidative stress in vivo. However, controversy exists in the literature around the amount of DHA detected in blood samples collected from various patient cohorts. In this study, we report on DHA concentrations in a selection of different clinical cohorts (diabetes, pneumonia, cancer, and critically ill). All clinical samples were collected into EDTA anticoagulant tubes and processed at 4 °C prior to storage at −80 °C for subsequent analysis by HPLC with electrochemical detection. We also investigated the effects of different handling and processing conditions on short-term and long-term ascorbate and DHA stability in vitro and in whole blood and plasma samples. These conditions included metal chelation, anticoagulants (EDTA and heparin), and processing temperatures (ice, 4 °C and room temperature). Analysis of our clinical cohorts indicated very low to negligible DHA concentrations. Samples exhibiting haemolysis contained significantly higher concentrations of DHA. Metal chelation inhibited oxidation of vitamin C in vitro, confirming the involvement of contaminating metal ions. Although EDTA is an effective metal chelator, complexes with transition metal ions are still redox active, thus its use as an anticoagulant can facilitate metal ion-dependent oxidation of vitamin C in whole blood and plasma. Handling and processing blood samples on ice (or at 4 °C) delayed oxidation of vitamin C by a number of hours. A review of the literature regarding DHA concentrations in clinical cohorts highlighted the fact that studies using colourimetric or fluorometric assays reported significantly higher concentrations of DHA compared to those using HPLC with electrochemical detection. In conclusion, careful handling and processing of samples, combined with appropriate analysis, is crucial for accurate determination of ascorbate and DHA in clinical samples. PMID:29439480

  12. Characterization of the March 2017 Tank 15 Waste Removal Slurry Sample (Combination of Slurry Samples HTF-15-17-28 and HTF-15-17-29)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reboul, S. H.; King, W. D.; Coleman, C. J.

    2017-05-09

    Two March 2017 Tank 15 slurry samples (HTF-15-17-28 and HTF-15-17-29) were collected during the second bulk waste removal campaign and submitted to SRNL for characterization. At SRNL, the two samples were combined and then characterized by a series of physical, elemental, radiological, and ionic analysis methods. Sludge settling as a function of time was also quantified. The characterization results reported in this document are consistent with expectations based upon waste type, process knowledge, comparisons between alternate analysis techniques, and comparisons with the characterization results obtained for the November 2016 Tank 15 slurry sample (the sample collected during the first bulkmore » waste removal campaign).« less

  13. Design of Microstructured Conducting Polymer Films for Enhanced Trace Explosives Detection

    NASA Astrophysics Data System (ADS)

    Laster, Jennifer S.

    The detection of trace amounts of explosive material is critical to national security. Ion mobility spectrometer (IMS)-based contact sampling continues to be a common method employed for the detection of explosives in high security checkpoint applications, such as airport security. In this process a surface of interest, such as a passenger's hands or luggage, is probed by a swab or particle trap to collect and transfer residue to an IMS for analysis. The collection of residue on a sampling swab has been shown to be a limiting step in this detection process. As such, there is significant need to develop new materials with increased adhesion to explosive analytes and with superior particle removal abilities. Here, the design of novel sampling swabs is presented for the enhanced collection of trace explosive residue from surfaces. First, the influence of the swab microstructure on the ability to remove particles from representative substrates is demonstrated. Free-standing microstructured polypyrrole (PPy) films of a variety of dimensions and form factors are fabricated using a templated electropolymerization process. The removal of polystyrene fluorescent particles from an aluminum substrate of varying surface roughness is examined as a function of the polymer microstructure. PPy microstructured films display enhanced particle removal abilities compared to PPy non-structured and current commercial films. This increase in particle removal is attributed to the increased particle-swab contact from the microstructured films. Next, the influence of the surface chemistry of sampling swabs on the collection of a representative explosive analyte, trinitrotoluene (TNT) is explored. The surface chemistry of PPy films is modified by electropolymerizaton of an N-substituted pyrrole monomer. The surface chemistries examined include a methyl, carboxylic acid, and amino-phenyl functionality. The vapor deposition of TNT on the surface of the functionalized PPy films is quantified through ultraviolet-visible (UV-vis) absorption and compared to commercial swabbing materials of varying chemistry and surface roughness. The PPy modified films with potential sites for hydrogen bonding display the highest deposition of TNT, while the Teflon coated commercial films display the lowest interaction with TNT. Finally, the desorption and release of TNT from sampling swabs is studied as an effect of temperature and of applied bias. For successful analyte detection within an IMS, the residue collected on a sampling swab must be released from the swab, typically through a thermal desorption process. In this work the release of TNT from sampling swabs is determined through solid-phase microextraction-gas chromatography mass spectrometry (SPME-GCMS). The results of this thesis provide important information on the design considerations for the development of novel particle sampling swabs with increased performance.

  14. Data Validation Package October 2016 Groundwater and Surface Water Sampling at the Monticello, Utah, Disposal and Processing Sites January 2017

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nguyen, Jason; Smith, Fred

    Sampling Period: October 10–12, 2016. This semiannual event includes sampling groundwater and surface water at the Monticello Disposal and Processing Sites. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated) and Program Directive MNT-2016-01. Samples were collected from 54 of 64 planned locations (16 of 17 former mill site wells, 15 of 18 downgradient wells, 7 of 9 downgradient permeable reactive barrier wells, 3 of 3 bedrock wells, 4 of 7 seeps and wetlands, and 9 of 10 surface water locations).

  15. Nature and origin of mineral coatings on volcanic rocks of the Black Mountain, Stonewall Mountain and Kane Springs wash volcanic centers, southern Nevada

    NASA Technical Reports Server (NTRS)

    Taranik, James V.; Noble, Donald C.; Hsu, Liang C.; Spatz, David M.

    1987-01-01

    Mineral coatings, including desert varnish on volcanic rocks of the semi-arid Basin and Range province are composted of amorphous, translucent films of Fe, Mn, Si, and Al rich compounds. Coatings are chiefly thin films that impregnate intergranularly to depths of about 0.1 to 0.3 mm, rarely deeper. Sixteen coating sections and subsurface interiors were probed by SEM; 20 samples were scanned by infrated spectrometry; 10 samples were scanned for visible-near IR spectra; inductin coupling plasma analyses were collected on 34 samples; 2 desert varnish surgaces were investigated by optical density slice imagery; a few XRD analyses were conducted in addition to the 50 reported in the last period; thin section observation continued; and imagery processing focused on classification techniques. In late May, approximately 10 field days were spent at the Stonewall and Black Mountain study sited conducting more detailed mapping and observation base on imagery results and collecting spectra with the Collins Field Spectrometer. Approximately 100 spectral analyses were collected and are currently being processed.

  16. Detection of Toxoplasma gondii in the milk of naturally infected goats in the Northeast of Brazil.

    PubMed

    Bezerra, M J G; Kim, P C P; Moraes, É P B X; Sá, S G; Albuquerque, P P F; Silva, J G; Alves, B H L S; Mota, R A

    2015-08-01

    The aim of the present study was to detect the genomic DNA of Toxoplasma gondii in milk samples from naturally infected goats in the state of Pernambuco, (Brazil). In total, 248 blood serum samples were collected and processed from lactating goats and then submitted to a search for antibodies to T. gondii through the indirect immunofluorescence reaction. Samples with a score of 64 or more were considered positive. In total, 248 milk samples were collected and processed from the same group of goats in order to study the DNA of T. gondii using the polymerase chain reaction (PCR) technique. In the serum samples, 56/248 (22.58%) of the animals were positive, whereas the DNA of the parasite was detected in 15/248 (6.05%) of the milk samples. Five of these 15 samples were animals who were also positive in the serology. This study reports the first occurrence of the elimination of T. gondii from the milk of naturally infected goats in the north-east of Brazil. It is suggested that the consumption of in natura goat milk may constitute a potential risk to the health of milk consumers in this region. © 2013 Blackwell Verlag GmbH.

  17. Sparking young minds with Moon rocks and meteorites

    NASA Technical Reports Server (NTRS)

    Taylor, G. Jeffrey; Lindstrom, Marilyn M.

    1993-01-01

    What could be more exciting than seeing pieces of other worlds? The Apollo program left a legacy of astounding accomplishments and precious samples. Part of the thrill of those lunar missions is brought to schools by the lunar sample educational disks, which contain artifacts of six piloted trips to the Moon. Johnson Space Center (JSC) is preparing 100 new educational disks containing pieces of meteorites collected in Antarctica. These represent chunks of several different asteroids, that were collected in one of the most remote, forbidding environments on Earth. These pieces of the Moon and asteroids represent the products of basic planetary processes (solar nebular processes, initial differentiation, volcanism, and impact), and, in turn, these processes are controlled by basic physical and chemical processes (energy, energy transfer, melting, buoyancy, etc.). Thus, the lunar and meteorite sample disks have enormous educational potential. New educational materials are being developed to accompany the disks. Present materials are not as effective as they could be, especially in relating samples to processes and to other types of data such as spectral studies and photogeology. Furthermore, the materials are out of date. New background materials will be produced for teachers, assembling slide sets with extensive captions, and devising numerous hands-on classroom activities to do while the disks are at a school and before and after they arrive. The classroom activities will be developed by teams of experienced teachers working with lunar and meteorite experts.

  18. Toxicity testing of sediment collected in the vicinity of effluent discharges from seafood processing plants in the maritimes.

    PubMed

    Lalonde, Benoit A; Jackman, Paula; Doe, Ken; Garron, Christine; Aubé, Jamie

    2009-04-01

    There are over 1100 fish-processing plants in Canada and the majority of them discharge untreated effluents directly to marine or estuarine receiving environments. The purpose of this study was to evaluate chemical and toxicological characteristics of sediments near fish-processing plant effluent discharges to assess potential impacts of seafood-processing effluents on receiving environments. Eighteen sediment samples were collected near effluent discharges of six seafood-processing plant outfalls in New Brunswick, Canada in the winter of 2006. Ammonia levels ranged from <0.2 to 3480 microg/g, sulfide levels ranged from <0.4 to 6970 microg/g, and redox ranged from -255 to 443 mV. Only one sample had a Microtox Solid-Phase Test IC(50) value below 1000 mg/kg, whereas three samples caused greater than 30% reduction to amphipod survival. Redox, sulfide, and ammonia concentrations were all found to be significantly related to both Eohaustorius estuarius survival and Microto (Vibrio fischeri) IC(50). An increase in sulfide (R (2) = 0.584; 0.750) and ammonia (R (2) = 0.478; 0.552) and a decrease in redox (R (2) = 0.485; 0.651) were associated with an increase in toxicity to E. estuarius and Microtox, respectively. The highest toxicity to both test organisms, and the most contaminated sediments based on physical/chemical characteristics measured, was observed in samples from Blacks Harbour.

  19. Results for the DWPF Slurry Mix Evaporator Condensate Tank, Off Gas Condensate Tank, And Recycle Collection Tank Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    TERRI, FELLINGER

    2004-12-21

    The Defense Waste Processing Facility, DWPF, currently generates approximately 1.4 million gallons of recycle water per year during Sludge-Only operations. DWPF has minimized condensate generation to 1.4 million gallons by not operating the Steam Atomized Scrubbers, SASs, for the melter off gas system. By not operating the SASs, DWPF has reduced the total volume by approximately 800,000 gallons of condensate per year. Currently, the recycle stream is sent to back to the Tank Farm and processed through the 2H Evaporator system. To alleviate the load on the 2H Evaporator system, an acid evaporator design is being considered as an alternatemore » processing and/or concentration method for the DWPF recycle stream. In order to support this alternate processing option, the DWPF has requested that the chemical and radionuclide compositions of the Off Gas Condensate Tank, OGCT, Slurry Mix Evaporator Condensate Tank, SMECT, Recycle Collection Tank, RCT, and the Decontamination Waste Treatment Tank, DWTT, be determined as a part of the process development work for the acid evaporator design. Samples have been retrieved from the OGCT, RCT, and SMECT and have been sent to the Savannah River National Laboratory, SRNL for this characterization. The DWTT samples have been recently shipped to SRNL. The results for the DWTT samples will be issued at later date.« less

  20. Terrestrial contamination in Apollo lunar samples.

    NASA Technical Reports Server (NTRS)

    Flory, D. A.; Simoneit, B. R.

    1972-01-01

    The contamination prevention procedures adopted for controlling the collection, processing, and analysis of the Apollo lunar samples in order to keep them free of significant levels of terrestrial organic matter are described. The organic contaminants actually found in the samples by the various investigators are summarized. It is shown that the program succeeded in providing investigators with samples containing less than 0.1 ppm total contamination.

  1. Use of Chironomidae (Diptera) Surface-Floating Pupal Exuviae as a Rapid Bioassessment Protocol for Water Bodies

    PubMed Central

    Kranzfelder, Petra; Anderson, Alyssa M.; Egan, Alexander T.; Mazack, Jane E.; Bouchard,, R. William; Rufer, Moriya M.; Ferrington,, Leonard C.

    2015-01-01

    Rapid bioassessment protocols using benthic macroinvertebrate assemblages have been successfully used to assess human impacts on water quality. Unfortunately, traditional benthic larval sampling methods, such as the dip-net, can be time-consuming and expensive. An alternative protocol involves collection of Chironomidae surface-floating pupal exuviae (SFPE). Chironomidae is a species-rich family of flies (Diptera) whose immature stages typically occur in aquatic habitats. Adult chironomids emerge from the water, leaving their pupal skins, or exuviae, floating on the water’s surface. Exuviae often accumulate along banks or behind obstructions by action of the wind or water current, where they can be collected to assess chironomid diversity and richness. Chironomids can be used as important biological indicators, since some species are more tolerant to pollution than others. Therefore, the relative abundance and species composition of collected SFPE reflect changes in water quality. Here, methods associated with field collection, laboratory processing, slide mounting, and identification of chironomid SFPE are described in detail. Advantages of the SFPE method include minimal disturbance at a sampling area, efficient and economical sample collection and laboratory processing, ease of identification, applicability in nearly all aquatic environments, and a potentially more sensitive measure of ecosystem stress. Limitations include the inability to determine larval microhabitat use and inability to identify pupal exuviae to species if they have not been associated with adult males. PMID:26274889

  2. Use of Chironomidae (Diptera) Surface-Floating Pupal Exuviae as a Rapid Bioassessment Protocol for Water Bodies.

    PubMed

    Kranzfelder, Petra; Anderson, Alyssa M; Egan, Alexander T; Mazack, Jane E; Bouchard, R William; Rufer, Moriya M; Ferrington, Leonard C

    2015-07-24

    Rapid bioassessment protocols using benthic macroinvertebrate assemblages have been successfully used to assess human impacts on water quality. Unfortunately, traditional benthic larval sampling methods, such as the dip-net, can be time-consuming and expensive. An alternative protocol involves collection of Chironomidae surface-floating pupal exuviae (SFPE). Chironomidae is a species-rich family of flies (Diptera) whose immature stages typically occur in aquatic habitats. Adult chironomids emerge from the water, leaving their pupal skins, or exuviae, floating on the water's surface. Exuviae often accumulate along banks or behind obstructions by action of the wind or water current, where they can be collected to assess chironomid diversity and richness. Chironomids can be used as important biological indicators, since some species are more tolerant to pollution than others. Therefore, the relative abundance and species composition of collected SFPE reflect changes in water quality. Here, methods associated with field collection, laboratory processing, slide mounting, and identification of chironomid SFPE are described in detail. Advantages of the SFPE method include minimal disturbance at a sampling area, efficient and economical sample collection and laboratory processing, ease of identification, applicability in nearly all aquatic environments, and a potentially more sensitive measure of ecosystem stress. Limitations include the inability to determine larval microhabitat use and inability to identify pupal exuviae to species if they have not been associated with adult males.

  3. Investigation of Mercury Wet Deposition Physicochemistry in the Ohio River Valley through Automated Sequential Sampling

    EPA Science Inventory

    Intra-storm variability and soluble fractionation was explored for summer-time rain events in Steubenville, Ohio to evaluate the physical processes controlling mercury (Hg) in wet deposition in this industrialized region. Comprehensive precipitation sample collection was conducte...

  4. Unmarked: An R package for fitting hierarchical models of wildlife occurrence and abundance

    USGS Publications Warehouse

    Fiske, I.J.; Chandler, R.B.

    2011-01-01

    Ecological research uses data collection techniques that are prone to substantial and unique types of measurement error to address scientic questions about species abundance and distribution. These data collection schemes include a number of survey methods in which unmarked individuals are counted, or determined to be present, at spatially- referenced sites. Examples include site occupancy sampling, repeated counts, distance sampling, removal sampling, and double observer sampling. To appropriately analyze these data, hierarchical models have been developed to separately model explanatory variables of both a latent abundance or occurrence process and a conditional detection process. Because these models have a straightforward interpretation paralleling mecha- nisms under which the data arose, they have recently gained immense popularity. The common hierarchical structure of these models is well-suited for a unied modeling in- terface. The R package unmarked provides such a unied modeling framework, including tools for data exploration, model tting, model criticism, post-hoc analysis, and model comparison.

  5. Silk-based blood stabilization for diagnostics.

    PubMed

    Kluge, Jonathan A; Li, Adrian B; Kahn, Brooke T; Michaud, Dominique S; Omenetto, Fiorenzo G; Kaplan, David L

    2016-05-24

    Advanced personalized medical diagnostics depend on the availability of high-quality biological samples. These are typically biofluids, such as blood, saliva, or urine; and their collection and storage is critical to obtain reliable results. Without proper temperature regulation, protein biomarkers in particular can degrade rapidly in blood samples, an effect that ultimately compromises the quality and reliability of laboratory tests. Here, we present the use of silk fibroin as a solid matrix to encapsulate blood analytes, protecting them from thermally induced damage that could be encountered during nonrefrigerated transportation or freeze-thaw cycles. Blood samples are recovered by simple dissolution of the silk matrix in water. This process is demonstrated to be compatible with a number of immunoassays and provides enhanced sample preservation in comparison with traditional air-drying paper approaches. Additional processing can remediate interactions with conformational structures of the silk protein to further enhance blood stabilization and recovery. This approach can provide expanded utility for remote collection of blood and other biospecimens empowering new modalities of temperature-independent remote diagnostics.

  6. Guidelines for quality assurance and quality control of fish taxonomic data collected as part of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Walsh, Stephen Joseph; Meador, Michael R.

    1998-01-01

    Fish community structure is characterized by the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) Program as part of a perennial, multidisciplinary approach to evaluating the physical, chemical, and biological conditions of the Nation's water resources. The objective of quality assurance and quality control of fish taxonomic data that are collected as part of the NAWQA Program is to establish uniform guidelines and protocols for the identification, processing, and archiving of fish specimens to ensure that accurate and reliable data are collected. Study unit biologists, collaborating with regional biologists and fish taxonomic specialists, prepare a pre-sampling study plan that includes a preliminary faunal list and identification of an ichthyological curation center for receiving preserved fish specimens. Problematic taxonomic issues and protected taxa also are identified in the study plan, and collecting permits are obtained in advance of sampling activities. Taxonomic specialists are selected to identify fish specimens in the field and to assist in determining what fish specimens should be sacrificed, fixed, and preserved for laboratory identification, independent taxonomic verification, and long-term storage in reference or voucher collections. Quantitative and qualitative sampling of fishes follows standard methods previously established for the NAWQA Program. Common ichthyological techniques are used to process samples in the field and prepare fish specimens to be returned to the laboratory or sent to an institutional repository. Taxonomic identifications are reported by using a standardized list of scientific names that provides nomenclatural consistency and uniformity across study units.

  7. Bioassay and biomolecular identification, sorting, and collection methods using magnetic microspheres

    DOEpatents

    Kraus, Jr., Robert H.; Zhou, Feng [Los Alamos, NM; Nolan, John P [Santa Fe, NM

    2007-06-19

    The present invention is directed to processes of separating, analyzing and/or collecting selected species within a target sample by use of magnetic microspheres including magnetic particles, the magnetic microspheres adapted for attachment to a receptor agent that can subsequently bind to selected species within the target sample. The magnetic microspheres can be sorted into a number of distinct populations, each population with a specific range of magnetic moments and different receptor agents can be attached to each distinct population of magnetic microsphere.

  8. Mapping individual logical processes in information searching

    NASA Technical Reports Server (NTRS)

    Smetana, F. O.

    1974-01-01

    An interactive dialog with a computerized information collection was recorded and plotted in the form of a flow chart. The process permits one to identify the logical processes employed in considerable detail and is therefore suggested as a tool for measuring individual thought processes in a variety of situations. A sample of an actual test case is given.

  9. Asbestiform minerals in ophiolitic rocks of Calabria (southern Italy).

    PubMed

    Campopiano, Antonella; Olori, Angelo; Spadafora, Alessandra; Rosaria Bruno, Maria; Angelosanto, Federica; Iannò, Antonino; Casciardi, Stefano; Giardino, Renato; Conte, Maurizio; Oranges, Teresa; Iavicoli, Sergio

    2018-03-22

    Ophiolitic rocks cropping on Calabria territory, southern Italy, can hold asbestiform minerals potentially harmful for human health. The aim of this work was to detect the fibrous phases of ophiolites along the Coastal Chain of northern Calabria and southern part of the Sila massif. Above 220 massive samples were collected in the study areas and analyzed using optical and electron microscopy, X-ray diffractometry, and Fourier transform infra-red spectrometry. The main fibrous constituent belonged to tremolite-actinolite series followed by fibrous antigorite that becomes more abundant in the samples collected in Reventino Mount surroundings. Results highlighted that serpentinites samples mainly consisted of antigorite and minor chrysotile. Samples collected along the coastal chain of northern Calabria did not hold fibrous materials. The results will be useful for Italian natural occurrences of asbestos (NOA) mapping in order to avoid an unintentional exposition by human activity or weathering processes.

  10. Data-quality measures for stakeholder-implemented watershed-monitoring programs

    USGS Publications Warehouse

    Greve, Adrienne I.

    2002-01-01

    Community-based watershed groups, many of which collect environmental data, have steadily increased in number over the last decade. The data generated by these programs are often underutilized due to uncertainty in the quality of data produced. The incorporation of data-quality measures into stakeholder monitoring programs lends statistical validity to data. Data-quality measures are divided into three steps: quality assurance, quality control, and quality assessment. The quality-assurance step attempts to control sources of error that cannot be directly quantified. This step is part of the design phase of a monitoring program and includes clearly defined, quantifiable objectives, sampling sites that meet the objectives, standardized protocols for sample collection, and standardized laboratory methods. Quality control (QC) is the collection of samples to assess the magnitude of error in a data set due to sampling, processing, transport, and analysis. In order to design a QC sampling program, a series of issues needs to be considered: (1) potential sources of error, (2) the type of QC samples, (3) inference space, (4) the number of QC samples, and (5) the distribution of the QC samples. Quality assessment is the process of evaluating quality-assurance measures and analyzing the QC data in order to interpret the environmental data. Quality assessment has two parts: one that is conducted on an ongoing basis as the monitoring program is running, and one that is conducted during the analysis of environmental data. The discussion of the data-quality measures is followed by an example of their application to a monitoring program in the Big Thompson River watershed of northern Colorado.

  11. 9 CFR 71.21 - Tissue and blood testing at slaughter.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., taking into account whether APHIS will be conducting complete tests at the facility, or only collecting..., until after the post-mortem examination is completed; (4) Includes tables, benches, and other equipment on which sample collection and processing are to be performed, of such design, material, and...

  12. The vanishing Black Indian: Revisiting craniometry and historic collections.

    PubMed

    Geller, Pamela L; Stojanowksi, Christopher M

    2017-02-01

    This article uses craniometric allocation as a platform for discussing the legacy of Samuel G. Morton's collection of crania, the process of racialization, and the value of contextualized biohistoric research perspectives in biological anthropology. Standard craniometric measurements were recorded for seven Seminoles in the Samuel G. Morton Crania Collection and 10 European soldiers from the Fort St. Marks Military Cemetery; all individuals were men and died in Florida during the 19th century. Fordisc 3.1 was used to assess craniometric affinity with respect to three samples: the Forensic Data Bank, Howells data set, and an archival sample that best fits the target populations collected from 19th century Florida. Discriminant function analyses were used to evaluate how allocations change across the three comparative databases, which roughly reflect a temporal sequence. Most Seminoles allocated as Native American, while most soldiers allocated as Euro-American. Allocation of Seminole crania, however, was unstable across analysis runs with more individuals identifying as African Americans when compared to the Howells and Forensic Data Bank. To the contrary, most of the soldiers produced consistent allocations across analyses. Repeatability for the St. Marks sample was lower when using the archival sample database, contrary to expectations. For the Seminole crania, Cohen's κ indicates significantly lower repeatability. A possible Black Seminole individual was identified in the Morton Collection. Recent articles discussing the merits and weaknesses of comparative craniometry focus on methodological issues. In our biohistoric approach, we use the patterning of craniometric allocations across databases as a platform for discussing social race and its development during the 19th century, a process known as racialization. Here we propose that differences in repeatability for the Seminoles and Euro-American soldiers reflect this process and transformation of racialized identities during 19th century U.S. nation-building. In particular, notions of whiteness were and remain tightly controlled, while other racial categorizations were affected by legal, social, and political contexts that resulted in hybridity in lieu of boundedness. © 2016 Wiley Periodicals, Inc.

  13. Automatic robotic arm operations and sampling in near zero gravity environment - functional tests results from Phobos-Grunt mission

    NASA Astrophysics Data System (ADS)

    Kozlova, Tatiana; Karol Seweryn, D..; Grygorczuk, Jerzy; Kozlov, Oleg

    The sample return missions have made a very significant progress to understanding of geology, the extra-terrestrial materials, processes occurring on surface and subsurface level, as well as of interactions between such materials and mechanisms operating there. The various sample return missions in the past (e.g. Apollo missions, Luna missions, Hayabusa mission) have provided scientists with samples of extra-terrestrial materials allowing to discover answers to critical scientific questions concerning the origin and evolution of the Solar System. Several new missions are currently planned: sample return missions, e.g Russian Luna-28, ESA Phootprint and MarcoPolo-R as well as both robotic and manned exploration missions to the Moon and Mars. One of the key challenges in such missions is the reliable sampling process which can be achieved by using many different techniques, e.g. static excavating technique (scoop), core drilling, sampling using dynamic mechanisms (penetrators), brushes and pneumatic systems. The effectiveness of any sampling strategy depends on many factors, including the required sample size, the mechanical and chemical soil properties (cohesive, hard or porous regolith, stones), the environment conditions (gravity, temperature, pressure, radiation). Many sampling mechanism have been studied, designed and built in the past, two techniques to collect regolith samples were chosen for the Phobos-Grunt mission. The proposed system consisted of a robotic arm with a 1,2m reach beyond the lander (IKI RAN); a tubular sampling device designed for collecting both regolith and small rock fragments (IKI RAN); the CHOMIK device (CBK PAN) - the low velocity penetrator with a single-sample container for collecting samples from the rocky surface. The functional tests were essential step in robotic arm, sampling device and CHOMIK device development process in the frame of Phobos-Grunt mission. Three major results were achieved: (i) operation scenario for autonomous sampling; (ii) technical characteristics of both devices, i.e. progress cycles of CHOMIK device in different materials and torque in the manipulator joints during sampling operations; (iii) confirmation of applicability of both devices to perform such type of tasks. The phases in operational scenario were prepared to meet mission and system requirements mainly connected with: (i) environment (near zero gravity, vacuum, dust), (ii) safety and (iii) to avoid common operation of both devices at the same time.

  14. Measuring myokines with cardiovascular functions: pre-analytical variables affecting the analytical output.

    PubMed

    Lombardi, Giovanni; Sansoni, Veronica; Banfi, Giuseppe

    2017-08-01

    In the last few years, a growing number of molecules have been associated to an endocrine function of the skeletal muscle. Circulating myokine levels, in turn, have been associated with several pathophysiological conditions including the cardiovascular ones. However, data from different studies are often not completely comparable or even discordant. This would be due, at least in part, to the whole set of situations related to the preparation of the patient prior to blood sampling, blood sampling procedure, processing and/or store. This entire process constitutes the pre-analytical phase. The importance of the pre-analytical phase is often not considered. However, in routine diagnostics, the 70% of the errors are in this phase. Moreover, errors during the pre-analytical phase are carried over in the analytical phase and affects the final output. In research, for example, when samples are collected over a long time and by different laboratories, a standardized procedure for sample collecting and the correct procedure for sample storage are acknowledged. In this review, we discuss the pre-analytical variables potentially affecting the measurement of myokines with cardiovascular functions.

  15. Technical Evaluation of Sample-Processing, Collection, and Preservation Methods

    DTIC Science & Technology

    2014-07-01

    For the Gram-positive organism, B. atrophaeus var. globigii (Unified Culture Collection [ UCC ] designation: BACI051) was selected as a surrogate for...the well-known biothreat agent Bacillus anthracis. For the Gram-negative organism, Y. pestis CO92 (pgm–) ( UCC designation: YERS059) was selected...Diagnostics device) TAMRA tetramethylrhodamine TE buffer tris-ethylenediaminetetraacetic acid buffer UCC Unified Culture Collection USG U.S. Government

  16. Laboratory procedures to generate viral metagenomes.

    PubMed

    Thurber, Rebecca V; Haynes, Matthew; Breitbart, Mya; Wegley, Linda; Rohwer, Forest

    2009-01-01

    This collection of laboratory protocols describes the steps to collect viruses from various samples with the specific aim of generating viral metagenome sequence libraries (viromes). Viral metagenomics, the study of uncultured viral nucleic acid sequences from different biomes, relies on several concentration, purification, extraction, sequencing and heuristic bioinformatic methods. No single technique can provide an all-inclusive approach, and therefore the protocols presented here will be discussed in terms of hypothetical projects. However, care must be taken to individualize each step depending on the source and type of viral-particles. This protocol is a description of the processes we have successfully used to: (i) concentrate viral particles from various types of samples, (ii) eliminate contaminating cells and free nucleic acids and (iii) extract, amplify and purify viral nucleic acids. Overall, a sample can be processed to isolate viral nucleic acids suitable for high-throughput sequencing in approximately 1 week.

  17. Automated apparatus for solvent separation of a coal liquefaction product stream

    DOEpatents

    Schweighardt, Frank K.

    1985-01-01

    An automated apparatus for the solvent separation of a coal liquefaction product stream that operates continuously and unattended and eliminates potential errors resulting from subjectivity and the aging of the sample during analysis. In use of the apparatus, metered amounts of one or more solvents are passed sequentially through a filter containing the sample under the direction of a microprocessor control means. The mixture in the filter is agitated by means of ultrasonic cavitation for a timed period and the filtrate is collected. The filtrate of each solvent extraction is collected individually and the residue on the filter element is collected to complete the extraction process.

  18. Chemistry Testing on Plasma Versus Serum Samples in Dialysis Patients: Clinical and Quality Improvement Implications.

    PubMed

    Carey, Roger Neill; Jani, Chinu; Johnson, Curtis; Pearce, Jim; Hui-Ng, Patricia; Lacson, Eduardo

    2016-09-07

    Plasma samples collected in tubes containing separator gels have replaced serum samples for most chemistry tests in many hospital and commercial laboratories. Use of plasma samples for blood tests in the dialysis population eliminates delays in sample processing while waiting for clotting to complete, laboratory technical issues associated with fibrin formation, repeat sample collection, and patient care issues caused by delay of results because of incompletely clotted specimens. Additionally, a larger volume of plasma is produced than serum for the same amount of blood collected. Plasma samples are also acceptable for most chemical tests involved in the care of patients with ESRD. This information becomes very important when United States regulatory requirements for ESRD inadvertently limit the type of sample that can be used for government reporting, quality assessment, and value-based payment initiatives. In this narrative, we summarize the renal community experience and how the subsequent resolution of the acceptability of phosphorus levels measured from serum and plasma samples may have significant implications in the country's continued development of a value-based Medicare ESRD Quality Incentive Program. Copyright © 2016 by the American Society of Nephrology.

  19. Use of Body-Mounted Cameras to Enhance Data Collection: An Evaluation of Two Arthropod Sampling Techniques.

    PubMed

    Hagler, James R; Thompson, Alison L; Stefanek, Melissa A; Machtley, Scott A

    2018-03-01

    A study was conducted that compared the effectiveness of a sweepnet versus a vacuum suction device for collecting arthropods in cotton. The study differs from previous research in that body-mounted action cameras (B-MACs) were used to record the activity of the person conducting the arthropod collections. The videos produced by the B-MACs were then analyzed with behavioral event recording software to quantify various aspects of the sampling process. The sampler's speed and the number of sampling sweeps or vacuum suctions taken over a fixed distance (12.2 m) of cotton were two of the more significant sampling characteristics quantified for each method. The arthropod counts obtained, combined with the analyses of the videos, enabled us to estimate arthropod sampling efficiency for each technique based on fixed distance, time, and sample unit measurements. Data revealed that the vacuuming was the most precise method for collecting arthropods in the relatively small cotton research plots. However, data also indicates that the sweepnet method would be more efficient for collecting most of the cotton-dwelling arthropod taxa, especially if the sampler could continuously sweep for at least 1 min or ≥80 m (e.g., in larger research plots). The B-MACs are inexpensive and non-cumbersome, the video images generated are outstanding, and they can be archived to provide permanent documentation of a research project. The methods described here could be useful for other types of field-based research to enhance data collection efficiency.

  20. The Generation R Study: Biobank update 2015.

    PubMed

    Kruithof, Claudia J; Kooijman, Marjolein N; van Duijn, Cornelia M; Franco, Oscar H; de Jongste, Johan C; Klaver, Caroline C W; Mackenbach, Johan P; Moll, Henriëtte A; Raat, Hein; Rings, Edmond H H M; Rivadeneira, Fernando; Steegers, Eric A P; Tiemeier, Henning; Uitterlinden, Andre G; Verhulst, Frank C; Wolvius, Eppo B; Hofman, Albert; Jaddoe, Vincent W V

    2014-12-01

    The Generation R Study is a population-based prospective cohort study from fetal life until adulthood. The study is designed to identify early environmental and genetic causes and causal pathways leading to normal and abnormal growth, development and health from fetal life, childhood and young adulthood. In total, 9,778 mothers were enrolled in the study. Data collection in children and their parents include questionnaires, interviews, detailed physical and ultrasound examinations, behavioural observations, Magnetic Resonance Imaging and biological samples. Efforts have been conducted for collecting biological samples including blood, hair, faeces, nasal swabs, saliva and urine samples and generating genomics data on DNA, RNA and microbiome. In this paper, we give an update of the collection, processing and storage of these biological samples and available measures. Together with detailed phenotype measurements, these biological samples provide a unique resource for epidemiological studies focused on environmental exposures, genetic and genomic determinants and their interactions in relation to growth, health and development from fetal life onwards.

  1. Characterization Data Package for Containerized Sludge Samples Collected from Engineered Container SCS-CON-210

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fountain, Matthew S.; Fiskum, Sandra K.; Baldwin, David L.

    This data package contains the K Basin sludge characterization results obtained by Pacific Northwest National Laboratory during processing and analysis of four sludge core samples collected from Engineered Container SCS-CON-210 in 2010 as requested by CH2M Hill Plateau Remediation Company. Sample processing requirements, analytes of interest, detection limits, and quality control sample requirements are defined in the KBC-33786, Rev. 2. The core processing scope included reconstitution of a sludge core sample distributed among four to six 4-L polypropylene bottles into a single container. The reconstituted core sample was then mixed and subsampled to support a variety of characterization activities. Additionalmore » core sludge subsamples were combined to prepare a container composite. The container composite was fractionated by wet sieving through a 2,000 micron mesh and a 500-micron mesh sieve. Each sieve fraction was sampled to support a suite of analyses. The core composite analysis scope included density determination, radioisotope analysis, and metals analysis, including the Waste Isolation Pilot Plant Hazardous Waste Facility Permit metals (with the exception of mercury). The container composite analysis included most of the core composite analysis scope plus particle size distribution, particle density, rheology, and crystalline phase identification. A summary of the received samples, core sample reconstitution and subsampling activities, container composite preparation and subsampling activities, physical properties, and analytical results are presented. Supporting data and documentation are provided in the appendices. There were no cases of sample or data loss and all of the available samples and data are reported as required by the Quality Assurance Project Plan/Sampling and Analysis Plan.« less

  2. Liquid chromatography and ultra-performance liquid chromatography-mass spectrometry fingerprinting of human urine: sample stability under different handling and storage conditions for metabonomics studies.

    PubMed

    Gika, Helen G; Theodoridis, Georgios A; Wilson, Ian D

    2008-05-02

    Typically following collection biological samples are kept in a freezer for periods ranging from a few days to several months before analysis. Experience has shown that in LC-MS-based metabonomics research the best analytical practice is to store samples as these are collected, complete the sample set and analyse it in a single run. However, this approach is prudent only if the samples stored in the refrigerator or in the freezer are stable. Another important issue is the stability of the samples following the freeze-thaw process. To investigate these matters urine samples were collected from 6 male volunteers and analysed by LC-MS and ultra-performance liquid chromatography (UPLC)-MS [in both positive and negative electrospray ionization (ESI)] on the day of collection or at intervals of up to 6 months storage at -20 degrees C and -80 degrees C. Other sets of these samples underwent a series of up to nine freeze-thaw cycles. The stability of samples kept at 4 degrees C in an autosampler for up to 6 days was also assessed, with clear differences appearing after 48h. Data was analysed using multivariate statistical analysis (principal component analysis). The results show that sample storage at both -20 and -80 degrees C appeared to ensure sample stability. Similarly up to nine freeze thaw cycles were without any apparent effect on the profile.

  3. Comparison of a novel passive sampler to standard water-column sampling for organic contaminants associated with wastewater effluents entering a New Jersey stream

    USGS Publications Warehouse

    Alvarez, D.A.; Stackelberg, P.E.; Petty, J.D.; Huckins, J.N.; Furlong, E.T.; Zaugg, S.D.; Meyer, M.T.

    2005-01-01

    Four water samples collected using standard depth and width water-column sampling methodology were compared to an innovative passive, in situ, sampler (the polar organic chemical integrative sampler or POCIS) for the detection of 96 organic wastewater-related contaminants (OWCs) in a stream that receives agricultural, municipal, and industrial wastewaters. Thirty-two OWCs were identified in POCIS extracts whereas 9-24 were identified in individual water-column samples demonstrating the utility of POCIS for identifying contaminants whose occurrence are transient or whose concentrations are below routine analytical detection limits. Overall, 10 OWCs were identified exclusively in the POCIS extracts and only six solely identified in the water-column samples, however, repetitive water samples taken using the standard method during the POCIS deployment period required multiple trips to the sampling site and an increased number of samples to store, process, and analyze. Due to the greater number of OWCs detected in the POCIS extracts as compared to individual water-column samples, the ease of performing a single deployment as compared to collecting and processing multiple water samples, the greater mass of chemical residues sequestered, and the ability to detect chemicals which dissipate quickly, the passive sampling technique offers an efficient and effective alternative for detecting OWCs in our waterways for wastewater contaminants.

  4. Review of sampling, sample and data collection procedures in nursing research--An example of research on ethical climate as perceived by nurses.

    PubMed

    Suhonen, Riitta; Stolt, Minna; Katajisto, Jouko; Leino-Kilpi, Helena

    2015-12-01

    To report a review of quality regarding sampling, sample and data collection procedures of empirical nursing research of ethical climate studies where nurses were informants. Surveys are needed to obtain generalisable information about topics sensitive to nursing. Methodological quality of the studies is of key concern, especially the description of sampling and data collection procedures. Methodological literature review. Using the electronic MEDLINE database, empirical nursing research articles focusing on ethical climate were accessed in 2013 (earliest-22 November 2013). Using the search terms 'ethical' AND ('climate*' OR 'environment*') AND ('nurse*' OR 'nursing'), 376 citations were retrieved. Based on a four-phase retrieval process, 26 studies were included in the detailed analysis. Sampling method was reported in 58% of the studies, and it was random in a minority of the studies (26%). The identification of target sample and its size (92%) was reported, whereas justification for sample size was less often given. In over two-thirds (69%) of the studies with identifiable response rate, it was below 75%. A variety of data collection procedures were used with large amount of missing data about the details of who distributed, recruited and collected the questionnaires. Methods to increase response rates were seldom described. Discussion about nonresponse, representativeness of the sample and generalisability of the results was missing in many studies. This review highlights the methodological challenges and developments that need to be considered in ensuring the use of valid information in developing health care through research findings. © 2015 Nordic College of Caring Science.

  5. 40 CFR 63.166 - Standards: Sampling connection systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... fluid to a process; or (3) Be designed and operated to capture and transport the purged process fluid to a control device that complies with the requirements of § 63.172 of this subpart; or (4) Collect... of subpart G of this part applicable to group 1 wastewater streams. If the purged process fluid does...

  6. 40 CFR 63.166 - Standards: Sampling connection systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... fluid to a process; or (3) Be designed and operated to capture and transport the purged process fluid to a control device that complies with the requirements of § 63.172 of this subpart; or (4) Collect... of subpart G of this part applicable to group 1 wastewater streams. If the purged process fluid does...

  7. Ground- and Surface-Water Chemistry of Handcart Gulch, Park County, Colorado, 2003-2006

    USGS Publications Warehouse

    Verplanck, Philip L.; Manning, Andrew H.; Kimball, Briant A.; McCleskey, R. Blaine; Runkel, Robert L.; Caine, Jonathan S.; Adams, Monique; Gemery-Hill, Pamela A.; Fey, David L.

    2008-01-01

    As part of a multidisciplinary project to determine the processes that control ground-water chemistry and flow in mineralized alpine environments, ground- and surface-water samples from Handcart Gulch, Colorado were collected for analysis of inorganic solutes and water and dissolved sulfate stable isotopes in selected samples. The primary aim of this study was to document variations in ground-water chemistry in Handcart Gulch and to identify changes in water chemistry along the receiving stream of Handcart Gulch. Water analyses are reported for ground-water samples collected from 12 wells in Handcart Gulch, Colorado. Samples were collected between August 2003 and October 2005. Water analyses for surface-water samples are reported for 50 samples collected from Handcart Gulch and its inflows during a low-flow tracer injection on August 6, 2003. In addition, water analyses are reported for three other Handcart Gulch stream samples collected in September 2005 and March 2006. Reported analyses include field parameters (pH, specific conductance, temperature, dissolved oxygen, and Eh), major and trace constituents, oxygen and hydrogen isotopic composition of water and oxygen and sulfur isotopic composition of dissolved sulfate. Ground-water samples from this study are Ca-SO4 type and range in pH from 2.5 to 6.8. Most of the samples (75 percent) have pH values between 3.3 and 4.3. Surface water samples are also Ca-SO4 type and have a narrower range in pH (2.7?4.0). Ground- and surface-water samples vary from relatively dilute (specific conductance of 68 ?S/cm) to concentrated (specific conductance of 2,000 ?S/cm).

  8. A sampling procedure to guide the collection of narrow-band, high-resolution spatially and spectrally representative reflectance data. [satellite imagery of earth resources

    NASA Technical Reports Server (NTRS)

    Brand, R. R.; Barker, J. L.

    1983-01-01

    A multistage sampling procedure using image processing, geographical information systems, and analytical photogrammetry is presented which can be used to guide the collection of representative, high-resolution spectra and discrete reflectance targets for future satellite sensors. The procedure is general and can be adapted to characterize areas as small as minor watersheds and as large as multistate regions. Beginning with a user-determined study area, successive reductions in size and spectral variation are performed using image analysis techniques on data from the Multispectral Scanner, orbital and simulated Thematic Mapper, low altitude photography synchronized with the simulator, and associated digital data. An integrated image-based geographical information system supports processing requirements.

  9. Collection of Viable Aerosolized Influenza Virus and Other Respiratory Viruses in a Student Health Care Center through Water-Based Condensation Growth

    PubMed Central

    Pan, Maohua; Bonny, Tania S.; Loeb, Julia; Jiang, Xiao; Eiguren-Fernandez, Arantzazu; Hering, Susanne; Fan, Z. Hugh; Wu, Chang-Yu

    2017-01-01

    ABSTRACT The dynamics and significance of aerosol transmission of respiratory viruses are still controversial, for the major reasons that virus aerosols are inefficiently collected by commonly used air samplers and that the collected viruses are inactivated by the collection method. Without knowledge of virus viability, infection risk analyses lack accuracy. This pilot study was performed to (i) determine whether infectious (viable) respiratory viruses in aerosols could be collected from air in a real world environment by the viable virus aerosol sampler (VIVAS), (ii) compare and contrast the efficacy of the standard bioaerosol sampler, the BioSampler, with that of the VIVAS for the collection of airborne viruses in a real world environment, and (iii) gain insights for the use of the VIVAS for respiratory virus sampling. The VIVAS operates via a water vapor condensation process to enlarge aerosolized virus particles to facilitate their capture. A variety of viable human respiratory viruses, including influenza A H1N1 and H3N2 viruses and influenza B viruses, were collected by the VIVAS located at least 2 m from seated patients, during a late-onset 2016 influenza virus outbreak. Whereas the BioSampler when operated following our optimized parameters also collected virus aerosols, it was nevertheless overall less successful based on a lower frequency of virus isolation in most cases. This side-by-side comparison highlights some limitations of past studies based on impingement-based sampling, which may have generated false-negative results due to either poor collection efficiency and/or virus inactivation due to the collection process. IMPORTANCE The significance of virus aerosols in the natural transmission of respiratory diseases has been a contentious issue, primarily because it is difficult to collect or sample virus aerosols using currently available air sampling devices. We tested a new air sampler based on water vapor condensation for efficient sampling of viable airborne respiratory viruses in a student health care center as a model of a real world environment. The new sampler outperformed the industry standard device (the SKC BioSampler) in the collection of natural virus aerosols and in maintaining virus viability. These results using the VIVAS indicate that respiratory virus aerosols are more prevalent and potentially pose a greater inhalation biohazard than previously thought. The VIVAS thus appears to be a useful apparatus for microbiology air quality tests related to the detection of viable airborne viruses. PMID:29034325

  10. Collection of Viable Aerosolized Influenza Virus and Other Respiratory Viruses in a Student Health Care Center through Water-Based Condensation Growth.

    PubMed

    Pan, Maohua; Bonny, Tania S; Loeb, Julia; Jiang, Xiao; Lednicky, John A; Eiguren-Fernandez, Arantzazu; Hering, Susanne; Fan, Z Hugh; Wu, Chang-Yu

    2017-01-01

    The dynamics and significance of aerosol transmission of respiratory viruses are still controversial, for the major reasons that virus aerosols are inefficiently collected by commonly used air samplers and that the collected viruses are inactivated by the collection method. Without knowledge of virus viability, infection risk analyses lack accuracy. This pilot study was performed to (i) determine whether infectious (viable) respiratory viruses in aerosols could be collected from air in a real world environment by the vi able v irus a erosol s ampler (VIVAS), (ii) compare and contrast the efficacy of the standard bioaerosol sampler, the BioSampler, with that of the VIVAS for the collection of airborne viruses in a real world environment, and (iii) gain insights for the use of the VIVAS for respiratory virus sampling. The VIVAS operates via a water vapor condensation process to enlarge aerosolized virus particles to facilitate their capture. A variety of viable human respiratory viruses, including influenza A H1N1 and H3N2 viruses and influenza B viruses, were collected by the VIVAS located at least 2 m from seated patients, during a late-onset 2016 influenza virus outbreak. Whereas the BioSampler when operated following our optimized parameters also collected virus aerosols, it was nevertheless overall less successful based on a lower frequency of virus isolation in most cases. This side-by-side comparison highlights some limitations of past studies based on impingement-based sampling, which may have generated false-negative results due to either poor collection efficiency and/or virus inactivation due to the collection process. IMPORTANCE The significance of virus aerosols in the natural transmission of respiratory diseases has been a contentious issue, primarily because it is difficult to collect or sample virus aerosols using currently available air sampling devices. We tested a new air sampler based on water vapor condensation for efficient sampling of viable airborne respiratory viruses in a student health care center as a model of a real world environment. The new sampler outperformed the industry standard device (the SKC BioSampler) in the collection of natural virus aerosols and in maintaining virus viability. These results using the VIVAS indicate that respiratory virus aerosols are more prevalent and potentially pose a greater inhalation biohazard than previously thought. The VIVAS thus appears to be a useful apparatus for microbiology air quality tests related to the detection of viable airborne viruses.

  11. Rapid separation and purification of uranium and plutonium from dilute-matrix samples

    DOE PAGES

    Armstrong, Christopher R.; Ticknor, Brian W.; Hall, Gregory; ...

    2014-03-11

    This work presents a streamlined separation and purification approach for trace uranium and plutonium from dilute (carrier-free) matrices. The method, effective for nanogram quantities of U and femtogram to picogram quantities of Pu, is ideally suited for environmental swipe samples that contain a small amount of collected bulk material. As such, it may be applicable for processing swipe samples such as those collected in IAEA inspection activities as well as swipes that are loaded with unknown analytes, such as those implemented in interlaboratory round-robin or proficiency tests. Additionally, the simplified actinide separation could find use in internal laboratory monitoring ofmore » clean room conditions prior to or following more extensive chemical processing. We describe key modifications to conventional techniques that result in a relatively rapid, cost-effective, and efficient U and Pu separation process. We demonstrate the efficacy of implementing anion exchange chromatography in a single column approach. We also show that hydrobromic acid is an effective substitute in lieu of hydroiodoic acid for eluting Pu. Lastly, we show that nitric acid is an effective digestion agent in lieu of perchloric acid and/or hydrofluoric acid. A step by step procedure of this process is detailed.« less

  12. Rapid DNA analysis for automated processing and interpretation of low DNA content samples.

    PubMed

    Turingan, Rosemary S; Vasantgadkar, Sameer; Palombo, Luke; Hogan, Catherine; Jiang, Hua; Tan, Eugene; Selden, Richard F

    2016-01-01

    Short tandem repeat (STR) analysis of casework samples with low DNA content include those resulting from the transfer of epithelial cells from the skin to an object (e.g., cells on a water bottle, or brim of a cap), blood spatter stains, and small bone and tissue fragments. Low DNA content (LDC) samples are important in a wide range of settings, including disaster response teams to assist in victim identification and family reunification, military operations to identify friend or foe, criminal forensics to identify suspects and exonerate the innocent, and medical examiner and coroner offices to identify missing persons. Processing LDC samples requires experienced laboratory personnel, isolated workstations, and sophisticated equipment, requires transport time, and involves complex procedures. We present a rapid DNA analysis system designed specifically to generate STR profiles from LDC samples in field-forward settings by non-technical operators. By performing STR in the field, close to the site of collection, rapid DNA analysis has the potential to increase throughput and to provide actionable information in real time. A Low DNA Content BioChipSet (LDC BCS) was developed and manufactured by injection molding. It was designed to function in the fully integrated Accelerated Nuclear DNA Equipment (ANDE) instrument previously designed for analysis of buccal swab and other high DNA content samples (Investigative Genet. 4(1):1-15, 2013). The LDC BCS performs efficient DNA purification followed by microfluidic ultrafiltration of the purified DNA, maximizing the quantity of DNA available for subsequent amplification and electrophoretic separation and detection of amplified fragments. The system demonstrates accuracy, precision, resolution, signal strength, and peak height ratios appropriate for casework analysis. The LDC rapid DNA analysis system is effective for the generation of STR profiles from a wide range of sample types. The technology broadens the range of sample types that can be processed and minimizes the time between sample collection, sample processing and analysis, and generation of actionable intelligence. The fully integrated Expert System is capable of interpreting a wide range or sample types and input DNA quantities, allowing samples to be processed and interpreted without a technical operator.

  13. How iSamples (Internet of Samples in the Earth Sciences) Improves Sample and Data Stewardship in the Next Generation of Geoscientists

    NASA Astrophysics Data System (ADS)

    Hallett, B. W.; Dere, A. L. D.; Lehnert, K.; Carter, M.

    2016-12-01

    Vast numbers of physical samples are routinely collected by geoscientists to probe key scientific questions related to global climate change, biogeochemical cycles, magmatic processes, mantle dynamics, etc. Despite their value as irreplaceable records of nature the majority of these samples remain undiscoverable by the broader scientific community because they lack a digital presence or are not well-documented enough to facilitate their discovery and reuse for future scientific and educational use. The NSF EarthCube iSamples Research Coordination Network seeks to develop a unified approach across all Earth Science disciplines for the registration, description, identification, and citation of physical specimens in order to take advantage of the new opportunities that cyberinfrastructure offers. Even as consensus around best practices begins to emerge, such as the use of the International Geo Sample Number (IGSN), more work is needed to communicate these practices to investigators to encourage widespread adoption. Recognizing the importance of students and early career scientists in particular to transforming data and sample management practices, the iSamples Education and Training Working Group is developing training modules for sample collection, documentation, and management workflows. These training materials are made available to educators/research supervisors online at http://earthcube.org/group/isamples and can be modularized for supervisors to create a customized research workflow. This study details the design and development of several sample management tutorials, created by early career scientists and documented in collaboration with undergraduate research students in field and lab settings. Modules under development focus on rock outcrops, rock cores, soil cores, and coral samples, with an emphasis on sample management throughout the collection, analysis and archiving process. We invite others to share their sample management/registration workflows and to develop training modules. This educational approach, with evolving digital materials, can help prepare future scientists to perform research in a way that will contribute to EarthCube data integration and discovery.

  14. AR-NE3A, a New Macromolecular Crystallography Beamline for Pharmaceutical Applications at the Photon Factory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamada, Yusuke; Hiraki, Masahiko; Sasajima, Kumiko

    2010-06-23

    Recent advances in high-throughput techniques for macromolecular crystallography have highlighted the importance of structure-based drug design (SBDD), and the demand for synchrotron use by pharmaceutical researchers has increased. Thus, in collaboration with Astellas Pharma Inc., we have constructed a new high-throughput macromolecular crystallography beamline, AR-NE3A, which is dedicated to SBDD. At AR-NE3A, a photon flux up to three times higher than those at existing high-throughput beams at the Photon Factory, AR-NW12A and BL-5A, can be realized at the same sample positions. Installed in the experimental hutch are a high-precision diffractometer, fast-readout, high-gain CCD detector, and sample exchange robot capable ofmore » handling more than two hundred cryo-cooled samples stored in a Dewar. To facilitate high-throughput data collection required for pharmaceutical research, fully automated data collection and processing systems have been developed. Thus, sample exchange, centering, data collection, and data processing are automatically carried out based on the user's pre-defined schedule. Although Astellas Pharma Inc. has a priority access to AR-NE3A, the remaining beam time is allocated to general academic and other industrial users.« less

  15. Emissions of fluorides from welding processes.

    PubMed

    Szewczyńska, Małgorzata; Pągowska, Emilia; Pyrzyńska, Krystyna

    2015-11-01

    The levels of fluoride airborne particulates emitted from welding processes were investigated. They were sampled with the patented IOM Sampler, developed by J. H. Vincent and D. Mark at the Institute of Occupational Medicine (IOM), personal inhalable sampler for simultaneous collection of the inhalable and respirable size fractions. Ion chromatography with conductometric detection was used for quantitative analysis. The efficiency of fluoride extraction from the cellulose filter of the IOM sampler was examined using the standard sample of urban air particle matter SRM-1648a. The best results for extraction were obtained when water and the anionic surfactant N-Cetyl-N-N-N-trimethylammonium bromide (CTAB) were used in an ultrasonic bath. The limits of detection and quantification for the whole procedure were 8μg/L and 24μg/L, respectively. The linear range of calibration was 0.01-10mg/L, which corresponds to 0.0001-0.1mg of fluorides per m(3) in collection of a 20L air sample. The concentration of fluorides in the respirable fraction of collected air samples was in the range of 0.20-1.82mg/m(3), while the inhalable fraction contained 0.23-1.96mg/m(3) of fluorides during an eight-hour working day in the welding room. Copyright © 2015. Published by Elsevier B.V.

  16. Propellant Residues Deposition from Firing of 40-mm Grenades

    DTIC Science & Technology

    2010-09-01

    the snow surface downrange of the firing positions in three sampling units on each pad. Samples were analyzed and results compo- sited to derive an...Processing and Analysis ..................................................................... 10 3.1 Snow samples...mm howitzers, propel- lant residues containing DNT were collected from the snow -covered area in front of one of the guns (Walsh, M.E. et al. 2004

  17. [Application of laboratory information system in the management of the key indicators of quality inspection].

    PubMed

    Guo, Ye; Chen, Qian; Wu, Wei; Cui, Wei

    2015-03-31

    To establish a system of monitoring the key indicator of quality for inspection (KIQI) on a laboratory information system (LIS), and to have a better management of KIQI. Clinical sample made in PUMCH were collected during the whole of 2014. Next, interactive input program were designed to accomplish data collecting of the disqualification rate of samples, the mistake rate of samples and the occasions of losing samples, etc. Then, a series moment of sample collection, laboratory sample arrived, sample test, sample check, response to critical value, namely, trajectory information left on LIS were recorded and the qualification rate of TAT, the notification rate of endangering result were calculated. Finally, the information about quality control were collected to build an internal quality control database and the KIQI, such as the out-of-control rate of quality control and the total error of test items were monitored. The inspection of the sample management shows the disqualification rates in 2014 were all below the target, but the rates in January and February were a little high and the rates of four wards were above 2%. The mistake rates of samples was 0.47 cases/10 000 cases, attaining the target (< 2 cases/10 000 cases). Also, there was no occasion of losing samples in 2014, attaining the target too. The inspection of laboratory reports shows the qualification rates of TAT was within the acceptable range (> 95%), however the rates of blood routine in November (94.75%) was out of range. We have solved the problem by optimizing the processes. The notification rate of endangering result attained the target (≥ 98%), while the rate of timely notification is needed to improve. Quality inspection shows the CV of APTT in August (5.02%) was rising significantly, beyond the accepted CV (5.0%). We have solved the problem by changing the reagent. The CV of TT in 2014 were all below the allowable CV, thus the allowable CV of the next year lower to 10%. It is an objective and effective method to manage KIQI with the powerful management mode of database and information process capability on LIS.

  18. A cryopreservation method for Pasteurella multocida from wetland samples

    USGS Publications Warehouse

    Moore, Melody K.; Shadduck, D.J.; Goldberg, Diana R.; Samuel, M.D.

    1998-01-01

    A cryopreservation method and improved isolation techniques for detection of Pasteurella multocida from wetland samples were developed. Wetland water samples were collected in the field, diluted in dimethyl sulfoxide (DMSO, final concentration 10%), and frozen at -180 C in a liquid nitrogen vapor shipper. Frozen samples were transported to the laboratory where they were subsequently thawed and processed in Pasteurella multocida selective broth (PMSB) to isolate P. multocida. This method allowed for consistent isolation of 2 to 18 organisms/ml from water seeded with known concentrations of P. multocida. The method compared favorably with the standard mouse inoculation method and allowed for preservation of the samples until they could be processed in the laboratory.

  19. Bias in fallout data from nuclear surface shot SMALL BOY: an evaluation of sample perturbation by sieve sizing. Technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pascual, J.N.

    1967-06-26

    Evaluation of sample bias introduced by the mechanical sieving of Small Boy fallout samples for 10 minutes revealed the following: Up to 20% of the mass and 30% of the gamma-ray activity can be lost from the large-particle (greater than 1400 microns) fraction. The pan fraction (less than 44 microns) can gain in weight by as much as 79%, and in activity by as much as 44%. The gamma-ray spectra of the fractions were not noticeably altered by the process. Examination of unbiased pan fractions (before mechanical sieving) indicated bimodality of the mass-size distribution in a sample collected 9,200 feetmore » from ground zero, but not in a sample collected at 13,300 feet.« less

  20. Atrazine degradation in a small stream in Iowa

    USGS Publications Warehouse

    Kolpin, D.W.; Kalkhoff, S.J.

    1993-01-01

    A study was conducted during 1990 through an 11.2-km reach of Roberts Creek in northeastern Iowa to determine the fate of atrazine in a surface water environment Water samples were collected at ~1-month intervals from April through November during stable low to medium flow conditions and analyzed for atrazine and two of its initial biotic degradation products, desethylatrazine and deisopropylatrazine. Samples were collected on the basis of a Lagrangian model of streamflow in order to sample the same parcel of water as it moved downstream. Atrazine concentrations substantially decreased (roughly 25-60%) between water entering and exiting the study reach during four of the seven sampling periods. During these same four sampling periods, the concentrations of the two biotic atrazine degradation products were constant or decreasing downstream, suggesting an abiotic degradation process.

  1. Qualitative research in nutrition and dietetics: data collection issues.

    PubMed

    Draper, A; Swift, J A

    2011-02-01

    The wide scope of qualitative enquiry presents the researcher with a number of choices regarding data collection and sampling. Selecting data collection and sampling techniques can therefore be somewhat daunting, particularly because, often, there is no single, universally accepted 'correct' option. Appropriate research methods are, however, crucial to ensure high-quality research. This review, the second in the series, provides an overview of the principal techniques of data collection and sampling that may be used for qualitative research in nutrition and dietetics. In addition, it describes a process for choosing appropriate data collection and sampling methods that considers the extent to which they provide data that answers the research question(s) and are compatible with the philosophical assumptions about ontology, epistemology and methodology that underpin the overall design of a study. Finally, it discusses the central role that the researcher plays in qualitative data collection and encourages researchers to acknowledge and reflect upon their impact on the data. Other reviews in this series provide a model for embarking on a qualitative research project in nutrition and dietetics, an overview of the principal techniques of data analysis and quality assessment of this kind of research, and some practical advice relevant to nutrition and dietetics, along with glossaries of key terms. © 2010 The Authors. Journal compilation © 2010 The British Dietetic Association Ltd.

  2. Suspended particulate matter collection methods influence the quantification of polycyclic aromatic compounds in the river system.

    PubMed

    Abuhelou, Fayez; Mansuy-Huault, Laurence; Lorgeoux, Catherine; Catteloin, Delphine; Collin, Valéry; Bauer, Allan; Kanbar, Hussein Jaafar; Gley, Renaud; Manceau, Luc; Thomas, Fabien; Montargès-Pelletier, Emmanuelle

    2017-10-01

    In this study, we compared the influence of two different collection methods, filtration (FT) and continuous flow field centrifugation (CFC), on the concentration and the distribution of polycyclic aromatic compounds (PACs) in suspended particulate matter (SPM) occurring in river waters. SPM samples were collected simultaneously with FT and CFC from a river during six sampling campaigns over 2 years, covering different hydrological contexts. SPM samples were analyzed to determine the concentration of PACs including 16 polycyclic aromatic hydrocarbons (PAHs), 11 oxygenated PACs (O-PACs), and 5 nitrogen PACs (N-PACs). Results showed significant differences between the two separation methods. In half of the sampling campaigns, PAC concentrations differed from a factor 2 to 30 comparing FT and CFC-collected SPMs. The PAC distributions were also affected by the separation method. FT-collected SPM were enriched in 2-3 ring PACs whereas CFC-collected SPM had PAC distributions dominated by medium to high molecular weight compounds typical of combustion processes. This could be explained by distinct cut-off threshold of the two separation methods and strongly suggested the retention of colloidal and/or fine matter on glass-fiber filters particularly enriched in low molecular PACs. These differences between FT and CFC were not systematic but rather enhanced by high water flow rates.

  3. Measurement of the intrinsic variability within protein crystals: implications for sample-evaluation and data-collection strategies.

    PubMed

    Bowler, Michael G; Bowler, Matthew W

    2014-01-01

    The advent of micro-focused X-ray beams has led to the development of a number of advanced methods of sample evaluation and data collection. In particular, multiple-position data-collection and helical oscillation strategies are now becoming commonplace in order to alleviate the problems associated with radiation damage. However, intra-crystal and inter-crystal variation means that it is not always obvious on which crystals or on which region or regions of a crystal these protocols should be performed. For the automation of this process for large-scale screening, and to provide an indication of the best strategy for data collection, a metric of crystal variability could be useful. Here, measures of the intrinsic variability within protein crystals are presented and their implications for optimal data-collection strategies are discussed.

  4. Development of a Standardized Approach for Environmental Microbiota Investigations related to Asthma Development in Children

    PubMed Central

    Fujimura, Kei E.; Rauch, Marcus; Matsui, Elizabeth; Iwai, Shoko; Calatroni, Agustin; Lynn, Henry; Mitchell, Herman; Johnson, Christine C.; Gern, James E.; Togias, Alkis; Boushey, Homer A.; Kennedy, Suzanne; Lynch, Susan V.

    2013-01-01

    Summary Standardized studies examining environmental microbial exposure in populations at risk for asthma are necessary to improve our understanding of the role this factor plays in disease development. Here we describe studies aimed at developing guidelines for high-resolution culture-independent microbiome profiling, using a phylogenetic microarray (PhyloChip), of house dust samples in a cohort collected as part of the NIH-funded Inner City Asthma Consortium (ICAC). We demonstrate that though extracted DNA concentrations varied across dust samples, the majority produced sufficient 16S rRNA to be profiled by the array. Comparison of array and 454-pyrosequencing performed in parallel on a subset of samples, illustrated that increasingly deeper sequencing efforts validated greater numbers of array-detected taxa. Community composition agreement across samples exhibited a hierarchy in concordance, with the highest level of agreement in replicate array profiles followed by samples collected from adjacent 1×1 m2 sites in the same room, adjacent sites with different sized sampling quadrants (1×1 and 2×2 m2), different sites within homes (living and bedroom) to lowest in living room samples collected from different homes. The guidelines for sample collection and processing in this pilot study extend beyond PhyloChip based studies of house-associated microbiota, and bear relevance for other microbiome profiling approaches such as next-generation sequencing. PMID:22975469

  5. Archival policies and collections database for the Woods Hole Science Center's marine sediment samples

    USGS Publications Warehouse

    Buczkowski, Brian J.; Kelsey, Sarah A.

    2007-01-01

    The Woods Hole Science Center of the U.S. Geological Survey (USGS) has been an active member of the Woods Hole research community, Woods Hole, Massachusetts, for over 40 years. In that time there have been many projects that involved the collection of sediment samples conducted by USGS scientists and technicians for the research and study of seabed environments and processes. These samples were collected at sea or near shore and then brought back to the Woods Hole Science Center (WHSC) for analysis. While at the center, samples are stored in ambient temperature, refrigerated and freezing conditions ranging from +2º Celsius to -18º Celsius, depending on the best mode of preparation for the study being conducted or the duration of storage planned for the samples. Recently, storage methods and available storage space have become a major concern at the WHSC. The core and sediment archive program described herein has been initiated to set standards for the management, methods, and duration of sample storage. A need has arisen to maintain organizational consistency and define storage protocol. This handbook serves as a reference and guide to all parties interested in using and accessing the WHSC's sample archive and also defines all the steps necessary to construct and maintain an organized collection of geological samples. It answers many questions as to the way in which the archive functions.

  6. Optical analyzer

    DOEpatents

    Hansen, A.D.

    1987-09-28

    An optical analyzer wherein a sample of particulate matter, and particularly of organic matter, which has been collected on a quartz fiber filter is placed in a combustion tube, and light from a light source is passed through the sample. The temperature of the sample is raised at a controlled rate and in a controlled atmosphere. The magnitude of the transmission of light through the sample is detected as the temperature is raised. A data processor, differentiator and a two pen recorder provide a chart of the optical transmission versus temperature and the rate of change of optical transmission versus temperature signatures (T and D) of the sample. These signatures provide information as to physical and chemical processes and a variety of quantitative and qualitative information about the sample. Additional information is obtained by repeating the run in different atmospheres and/or different rates or heating with other samples of the same particulate material collected on other filters. 7 figs.

  7. Source Testing for Particulate Matter.

    ERIC Educational Resources Information Center

    DeVorkin, Howard

    Developed for presentation at the 12th Conference on Methods in Air Pollution and Industrial Hygiene Studies, University of Southern California, April, 1971, this outline covers procedures for the testing of particulate matter. These are: (1) basic requirements, (2) information required, (3) collection of samples, (4) processing of samples, (5)…

  8. Novel microbial diversity retrieved by autonomous robotic exploration of the world's deepest vertical phreatic sinkhole.

    PubMed

    Sahl, Jason W; Fairfield, Nathaniel; Harris, J Kirk; Wettergreen, David; Stone, William C; Spear, John R

    2010-03-01

    The deep phreatic thermal explorer (DEPTHX) is an autonomous underwater vehicle designed to navigate an unexplored environment, generate high-resolution three-dimensional (3-D) maps, collect biological samples based on an autonomous sampling decision, and return to its origin. In the spring of 2007, DEPTHX was deployed in Zacatón, a deep (approximately 318 m), limestone, phreatic sinkhole (cenote) in northeastern Mexico. As DEPTHX descended, it generated a 3-D map based on the processing of range data from 54 onboard sonars. The vehicle collected water column samples and wall biomat samples throughout the depth profile of the cenote. Post-expedition sample analysis via comparative analysis of 16S rRNA gene sequences revealed a wealth of microbial diversity. Traditional Sanger gene sequencing combined with a barcoded-amplicon pyrosequencing approach revealed novel, phylum-level lineages from the domains Bacteria and Archaea; in addition, several novel subphylum lineages were also identified. Overall, DEPTHX successfully navigated and mapped Zacatón, and collected biological samples based on an autonomous decision, which revealed novel microbial diversity in a previously unexplored environment.

  9. Microbiological test results of the environmental control and life support systems vapors compression distillation subsystem recycle tank components following various pretreatment protocols

    NASA Technical Reports Server (NTRS)

    Huff, Tim

    1993-01-01

    Microbiological samples were collected from the recycle tank of the vapor compression distillation (VCD) subsystem of the water recovery test at NASA MSFC following a 68-day run. The recycle tank collects rejected urine brine that was pretreated with a commercially available oxidant (Oxone) and sulfuric acid and pumps it back to the processing component of the VCD. Samples collected included a water sample and two swab samples, one from the particulate filter surface and a second from material floating on the surface of the water. No bacteria were recovered from the water sample. Both swab samples contained a spore-forming bacterium, Bacillus insolitus. A filamentous fungus was isolated from the floating material. Approximately 1 month after the pretreatment chemicals were changed to sodium hypochlorite and sulfuric acid, a swab of the particulate filter was again analyzed for microbial content. One fungus was isolated, and spore-forming bacteria were observed. These results indicate the inability of these pretreatments to inhibit surface attachment. The implications of the presence of these organisms are discussed.

  10. Use the Bar Code System to Improve Accuracy of the Patient and Sample Identification.

    PubMed

    Chuang, Shu-Hsia; Yeh, Huy-Pzu; Chi, Kun-Hung; Ku, Hsueh-Chen

    2018-01-01

    In time and correct sample collection were highly related to patient's safety. The sample error rate was 11.1%, because misbranded patient information and wrong sample containers during January to April, 2016. We developed a barcode system of "Specimens Identify System" through process of reengineering of TRM, used bar code scanners, add sample container instructions, and mobile APP. Conclusion, the bar code systems improved the patient safety and created green environment.

  11. Gastrointestinal parasites among felids inhabiting the Serra dos Órgãos National Park, Rio de Janeiro, Brazil.

    PubMed

    Dib, Laís Verdan; Cronemberger, Cecília; Pereira, Fabiane de Aguiar; Bolais, Paula Forain; Uchôa, Claudia Maria Antunes; Bastos, Otilio Machado Pereira; Amendoeira, Maria Regina Reis; Barbosa, Alynne da Silva

    2018-05-24

    This study aimed to investigate the species of felids that inhabit the Serra dos Órgãos National Park (Parnaso) and gastrointestinal parasites at various stages of their life cycles in the feces of these animals. Between 2013 and 2015, felid feces were collected from trails in Parnaso. The sampling points were georeferenced. A total of 82 fecal samples were processed, of which 79 were collected on the ground, two from captured felids and one from a necropsied animal. All samples underwent coproparasitological techniques. Samples collected from the environment underwent additional trichological analysis. Fur patterns corresponding to Leopardus guttulus, Leopardus pardalis, Leopardus wiedii and Puma yagouaroundi were observed in 32 of the samples collected on the soil. High frequency of potentially parasitic evolving forms (88.6%) was observed in felid feces, particularly eggs of the family Diphyllobothriidae (68.6%). Besides, were also detected, eggs of superfamily Ascaridoidea (42.9%), nematode larvae (28.6%), eggs of order Strongylida (28.6%), Capillaria sp. (8.6%), Trichuris sp. (8.6%), eggs of order Spirurida (2.9%), unsporulated coccidian oocysts (8.6%) and Eimeria sp. (2.9%). Felid feces presented higher frequency of polyparasitism (60%) than monoparasitism (28.6%).

  12. Evaluation of OMNIgene®•SPUTUM-stabilised sputum for long-term transport and Xpert® MTB/RIF testing in Nepal.

    PubMed

    Maharjan, B; Kelly-Cirino, C D; Weirich, A; Curry, P S; Hoffman, H; Avsar, K; Shrestha, B

    2016-12-01

    German Nepal TB Project, National Tuberculosis Reference Laboratory, Kathmandu, Nepal. To evaluate whether transporting samples in OMNIgene®•SPUTUM (OM-S) reagent from a peripheral collection site to a central laboratory in Nepal can improve tuberculosis (TB) detection and increase the sensitivity of Xpert® MTB/RIF testing. One hundred sputum samples were split manually. Each portion was assigned to the OM-S group (OM-S added at collection, airline-couriered without cold chain, no other processing required) or the standard-of-care (SOC) group (samples airline-couriered on ice, sodium hydroxide + N-acetyl-L-cysteine processing required at the laboratory). Smear microscopy and Xpert testing were performed. Transport time was 2-13 days. Overall smear results were comparable (respectively 58% and 56% smear-negative results in the OM-S and SOC groups). The rate of smear-positive, Mycobacterium tuberculosis-positive (MTB+) sample detection was identical for both treatment groups, at 95%. More smear-negative MTB+ samples were detected in the OM-S group (17% vs. 13%, P = 0.0655). Sputum samples treated with OM-S can undergo multiday ambient-temperature transport and yield comparable smear and Xpert results to those of SOC samples. Further investigation with larger sample sizes is required to assess whether treating sputum samples with OM-S could increase the sensitivity of Xpert testing in smear-negative samples.

  13. 77 FR 76043 - Agency Information Collection Activities: Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-26

    ... a pretest of these questions on a sampled set of 2012 MEPS-IC survey respondents. A telephone pretest was conducted in the spring and summer of 2012. The results of this pretest, conducted under the Census Bureau's generic pretest clearance process, led to AHRQ recommending that a subset of the tested...

  14. Measuring suspended sediment in small mountain streams

    Treesearch

    Robert B. Thomas

    1985-01-01

    Measuring suspended sediment concentration in streams provides a way of monitoring the effects of forest management activities on water quality. Collecting data on suspended sediment is an act of sampling. The nature of the delivery process and the circumstances under which data are collected combine to produce highly variable results that are difficult to analyze and...

  15. Authenticity in Teaching: A Constant Process of Becoming

    ERIC Educational Resources Information Center

    Ramezanzadeh, Akram; Zareian, Gholamreza; Adel, Seyyed Mohammad Reza; Ramezanzadeh, Ramin

    2017-01-01

    This study probed the conceptualization of (in)authenticity in teaching and the way it could be enacted in pedagogical practices. The participants were a purposive sample of 20 Iranian university teachers. Data were collected using in-depth interviews, field notes, and observation. The collected data were analyzed through the lens of hermeneutic…

  16. Unnecessary roughness? Testing the hypothesis that predators destined for molecular gut-content analysis must be hand-collected to avoid cross-contamination

    USDA-ARS?s Scientific Manuscript database

    Molecular gut-content analysis enables direct detection of arthropod predation with minimal disruption of on-going ecosystem processes. Mass-collection methods, such as sweep-netting, vacuum sampling, and foliage beating, could lead to regurgitation or even rupturing of predators along with uneaten ...

  17. Current laboratory requirements for adrenocorticotropic hormone and renin/aldosterone sample handling are unnecessarily restrictive.

    PubMed

    Chakera, Ali J; McDonald, Timothy J; Knight, Bridget A; Vaidya, Bijay; Jones, Angus G

    2017-02-01

    Samples for adrenocorticotropic hormone (ACTH) and aldosterone/renin analysis usually require rapid transport to the receiving laboratory for immediate separation and freezing. In practice, this means assessment is limited to hospital settings and many samples are rejected. We examined whether these requirements are necessary by assessing the stability of ACTH, aldosterone and renin over 48 hours in whole blood collected in serum gel and EDTA plasma from 31 participants. Our results show that ACTH collected into EDTA plasma is stable at room temperature for at least 6 hours, mean change at 6 hours -2.6% (95% CI -9.7 to 4.5). Both aldosterone and renin were stable collected on serum gel at room temperature for at least 6 hours: mean change aldosterone +0.2% (95% CI -3.6 to 4.0), renin -1.9% (95% CI -7.0 to3.2). Therefore, by using appropriate preservatives, ACTH and aldosterone/renin can be measured on samples collected at room temperature and processed within 6 hours. This would facilitate outpatient and emergency room assessment of these analytes. © Royal College of Physicians 2017. All rights reserved.

  18. Microsystem strategies for sample preparation in biological detection.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    James, Conrad D.; Galambos, Paul C.; Bennett, Dawn Jonita

    2005-03-01

    The objective of this LDRD was to develop microdevice strategies for dealing with samples to be examined in biological detection systems. This includes three sub-components: namely, microdevice fabrication, sample delivery to the microdevice, and sample processing within the microdevice. The first component of this work focused on utilizing Sandia's surface micromachining technology to fabricate small volume (nanoliter) fluidic systems for processing small quantities of biological samples. The next component was to develop interfaces for the surface-micromachined silicon devices. We partnered with Micronics, a commercial company, to produce fluidic manifolds for sample delivery to our silicon devices. Pressure testing was completedmore » to examine the strength of the bond between the pressure-sensitive adhesive layer and the silicon chip. We are also pursuing several other methods, both in house and external, to develop polymer-based fluidic manifolds for packaging silicon-based microfluidic devices. The second component, sample processing, is divided into two sub-tasks: cell collection and cell lysis. Cell collection was achieved using dielectrophoresis, which employs AC fields to collect cells at energized microelectrodes, while rejecting non-cellular particles. Both live and dead Staph. aureus bacteria have been collected using RF frequency dielectrophoresis. Bacteria have been separated from polystyrene microspheres using frequency-shifting dielectrophoresis. Computational modeling was performed to optimize device separation performance, and to predict particle response to the dielectrophoretic traps. Cell lysis is continuing to be pursued using microactuators to mechanically disrupt cell membranes. Novel thermal actuators, which can generate larger forces than previously tested electrostatic actuators, have been incorporated with and tested with cell lysis devices. Significant cell membrane distortion has been observed, but more experiments need to be conducted to determine the effects of the observed distortion on membrane integrity and cell viability. Finally, we are using a commercial PCR DNA amplification system to determine the limits of detectable sample size, and to examine the amplification of DNA bound to microspheres. Our objective is to use microspheres as capture-and-carry chaperones for small molecules such as DNA and proteins, enabling the capture and concentration of the small molecules using dielectrophoresis. Current tests demonstrated amplification of DNA bound to micron-sized polystyrene microspheres using 20-50 microliter volume size reactions.« less

  19. NASA Biological Specimen Repository

    NASA Technical Reports Server (NTRS)

    McMonigal, K. A.; Pietrzyk, R. A.; Sams, C. F.; Johnson, M. A.

    2010-01-01

    The NASA Biological Specimen Repository (NBSR) was established in 2006 to collect, process, preserve and distribute spaceflight-related biological specimens from long duration ISS astronauts. This repository provides unique opportunities to study longitudinal changes in human physiology spanning may missions. The NBSR collects blood and urine samples from all participating ISS crewmembers who have provided informed consent. These biological samples are collected once before flight, during flight scheduled on flight days 15, 30, 60, 120 and within 2 weeks of landing. Postflight sessions are conducted 3 and 30 days after landing. The number of in-flight sessions is dependent on the duration of the mission. Specimens are maintained under optimal storage conditions in a manner that will maximize their integrity and viability for future research The repository operates under the authority of the NASA/JSC Committee for the Protection of Human Subjects to support scientific discovery that contributes to our fundamental knowledge in the area of human physiological changes and adaptation to a microgravity environment. The NBSR will institute guidelines for the solicitation, review and sample distribution process through establishment of the NBSR Advisory Board. The Advisory Board will be composed of representatives of all participating space agencies to evaluate each request from investigators for use of the samples. This process will be consistent with ethical principles, protection of crewmember confidentiality, prevailing laws and regulations, intellectual property policies, and consent form language. Operations supporting the NBSR are scheduled to continue until the end of U.S. presence on the ISS. Sample distribution is proposed to begin with selections on investigations beginning in 2017. The availability of the NBSR will contribute to the body of knowledge about the diverse factors of spaceflight on human physiology.

  20. The Use of Handheld X-Ray Fluorescence (XRF) Technology in Unraveling the Eruptive History of the San Francisco Volcanic Field, Arizona

    NASA Technical Reports Server (NTRS)

    Young, Kelsey E.; Evans, C. A.; Hodges, K. V.

    2012-01-01

    While traditional geologic mapping includes the examination of structural relationships between rock units in the field, more advanced technology now enables us to simultaneously collect and combine analytical datasets with field observations. Information about tectonomagmatic processes can be gleaned from these combined data products. Historically, construction of multi-layered field maps that include sample data has been accomplished serially (first map and collect samples, analyze samples, combine data, and finally, readjust maps and conclusions about geologic history based on combined data sets). New instruments that can be used in the field, such as a handheld xray fluorescence (XRF) unit, are now available. Targeted use of such instruments enables geologists to collect preliminary geochemical data while in the field so that they can optimize scientific data return from each field traverse. Our study tests the application of this technology and projects the benefits gained by real-time geochemical data in the field. The integrated data set produces a richer geologic map and facilitates a stronger contextual picture for field geologists when collecting field observations and samples for future laboratory work. Real-time geochemical data on samples also provide valuable insight regarding sampling decisions by the field geologist

  1. Placers of cosmic dust in the blue ice lakes of Greenland

    NASA Technical Reports Server (NTRS)

    Maurette, M.; Hammer, C.; Reeh, N.; Brownlee, D. E.; Thomsen, H. H.

    1986-01-01

    A concentration process occurring in the melt zone of the Greenland ice cap has produced the richest known deposit of cosmic dust on the surface of the earth. Extraterrestrial particles collected from this region are well preserved and are collectable in large quantities. The collected particles are generally identical to cosmic spheres found on the ocean floor, but a pure glass type was discovered that has not been seen in deep-sea samples. Iron-rich spheres are conspicuously rare in the collected material.

  2. Variability in, variability out: best practice recommendations to standardize pre-analytical variables in the detection of circulating and tissue microRNAs.

    PubMed

    Khan, Jenna; Lieberman, Joshua A; Lockwood, Christina M

    2017-05-01

    microRNAs (miRNAs) hold promise as biomarkers for a variety of disease processes and for determining cell differentiation. These short RNA species are robust, survive harsh treatment and storage conditions and may be extracted from blood and tissue. Pre-analytical variables are critical confounders in the analysis of miRNAs: we elucidate these and identify best practices for minimizing sample variation in blood and tissue specimens. Pre-analytical variables addressed include patient-intrinsic variation, time and temperature from sample collection to storage or processing, processing methods, contamination by cells and blood components, RNA extraction method, normalization, and storage time/conditions. For circulating miRNAs, hemolysis and blood cell contamination significantly affect profiles; samples should be processed within 2 h of collection; ethylene diamine tetraacetic acid (EDTA) is preferred while heparin should be avoided; samples should be "double spun" or filtered; room temperature or 4 °C storage for up to 24 h is preferred; miRNAs are stable for at least 1 year at -20 °C or -80 °C. For tissue-based analysis, warm ischemic time should be <1 h; cold ischemic time (4 °C) <24 h; common fixative used for all specimens; formalin fix up to 72 h prior to processing; enrich for cells of interest; validate candidate biomarkers with in situ visualization. Most importantly, all specimen types should have standard and common workflows with careful documentation of relevant pre-analytical variables.

  3. Northern Marshall Islands radiological survey: sampling and analysis summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robison, W.L.; Conrado, C.L.; Eagle, R.J.

    1981-07-23

    A radiological survey was conducted in the Northern Marshall Islands to document reamining external gamma exposures from nuclear tests conducted at Enewetak and Bikini Atolls. An additional program was later included to obtain terrestrial and marine samples for radiological dose assessment for current or potential atoll inhabitants. This report is the first of a series summarizing the results from the terrestrial and marine surveys. The sample collection and processing procedures and the general survey methodology are discussed; a summary of the collected samples and radionuclide analyses is presented. Over 5400 samples were collected from the 12 atolls and 2 islandsmore » and prepared for analysis including 3093 soil, 961 vegetation, 153 animal, 965 fish composite samples (average of 30 fish per sample), 101 clam, 50 lagoon water, 15 cistern water, 17 groundwater, and 85 lagoon sediment samples. A complete breakdown by sample type, atoll, and island is given here. The total number of analyses by radionuclide are 8840 for /sup 241/Am, 6569 for /sup 137/Cs, 4535 for /sup 239 +240/Pu, 4431 for /sup 90/Sr, 1146 for /sup 238/Pu, 269 for /sup 241/Pu, and 114 each for /sup 239/Pu and /sup 240/Pu. A complete breakdown by sample category, atoll or island, and radionuclide is also included.« less

  4. Data Validation Package - June 2016 Groundwater and Surface Water Sampling at the Green River, Utah, Disposal Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Linard, Joshua; Price, Jeffrey

    This event included annual sampling of groundwater and surface water locations at the Green River, Utah, Disposal Site. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for US. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lrnldownloads/sampling-and- analysis-plan-us-department-energy-office-legacy-management-sites). Samples were collected from 15 monitoring wells and two surface locations at the disposal site as specified in the draft 2011 Ground Water Compliance Action Plan for the Green River, Utah, Disposal Site. Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. A duplicate sample was collected from location 0179. Onemore » equipment blank was collected during this sampling event. Water levels were measured at all monitoring wells that were sampled. See Attachment 2, Trip Reports for additional details. The analytical data and associated qualifiers can be viewed in environmental database reports and are also available for viewing with dynamic mapping via the GEMS (Geospatial Environmental Mapping System) website at http://gems.lm.doe.gov/#. No issues were identified during the data validation process that requires additional action or follow-up.« less

  5. Determination and comparison of microbial loads in atmospheres of two hospitals in Izmir, Turkey.

    PubMed

    Aydin Çakir, Nergüze; Uçar, Füsun Bahriye; Haliki Uztan, Alev; Corbaci, Cengiz; Akpinar, Onur

    2013-01-01

    Nosocomial infections, also known as hospital-acquired infections, has become one of the most important health problems in health care units worldwide. The presented study aims to determine the average amount of microorganism loads and to show that the atmospheres of the two hospitals can be a potential source regarding nosocomial infections. The effect of surface and floor disinfection processes in the two hospitals and the antibiotic susceptibility of the bacterial isolates were also evaluated. Microorganisms were isolated from air samples collected from different areas (patient wards, corridors, operating theatres and postoperative units) of the two hospitals in Izmir. Sampling was conducted between December 2006 - March 2007. During the 3-month sampling period, the average number of live microorganisms in the air samples collected from second-class environments in the hospital 1 and the hospital 2 was found to be 224.44 and 536.66 cfu/m(3) , respectively. The average number of microorganisms in hospital 2 collected before the disinfection process was higher than those after the disinfection process. However, because of the closure of the air-conditioning system and the hepa filters after the disinfection process, this was reversed in hospital 1. In total, 54 and 42 isolates were obtained from hospital 1 and hospital 2, respectively. 49 isolates from hospital 1 and 35 isolates from hospital 2 were identified as Staphylacoccus sp. The remaining isolates were identified as Aerococcus sp. and Enterococcus sp. Pseudomonas sp. was not determined in the air samples of the two hospitals. It was detected that the microbial loads in the atmospheres of the two hospitals studied varied greatly depending on the number of people in the environment. As the results indicate, the total number of microorganisms in the atmospheres of operating theatres in both hospitals does not pose a threat according to the Air Microbe Index.

  6. Development of an automated data processing method for sample to sample comparison of seized methamphetamines.

    PubMed

    Choe, Sanggil; Lee, Jaesin; Choi, Hyeyoung; Park, Yujin; Lee, Heesang; Pyo, Jaesung; Jo, Jiyeong; Park, Yonghoon; Choi, Hwakyung; Kim, Suncheun

    2012-11-30

    The information about the sources of supply, trafficking routes, distribution patterns and conspiracy links can be obtained from methamphetamine profiling. The precursor and synthetic method for the clandestine manufacture can be estimated from the analysis of minor impurities contained in methamphetamine. Also, the similarity between samples can be evaluated using the peaks that appear in chromatograms. In South Korea, methamphetamine was the most popular drug but the total seized amount of methamphetamine whole through the country was very small. Therefore, it would be more important to find the links between samples than the other uses of methamphetamine profiling. Many Asian countries including Japan and South Korea have been using the method developed by National Research Institute of Police Science of Japan. The method used gas chromatography-flame ionization detector (GC-FID), DB-5 column and four internal standards. It was developed to increase the amount of impurities and minimize the amount of methamphetamine. After GC-FID analysis, the raw data have to be processed. The data processing steps are very complex and require a lot of time and effort. In this study, Microsoft Visual Basic Application (VBA) modules were developed to handle these data processing steps. This module collected the results from the data into an Excel file and then corrected the retention time shift and response deviation generated from the sample preparation and instruments analysis. The developed modules were tested for their performance using 10 samples from 5 different cases. The processed results were analyzed with Pearson correlation coefficient for similarity assessment and the correlation coefficient of the two samples from the same case was more than 0.99. When the modules were applied to 131 seized methamphetamine samples, four samples from two different cases were found to have the common origin and the chromatograms of the four samples were appeared visually identical. The developed VBA modules could process raw data of GC-FID very quickly and easily. Also, they could assess the similarity between samples by peak pattern recognition using whole peaks without spectral identification of each peak that appeared in the chromatogram. The results collectively suggest that the modules would be useful tools to augment similarity assessment between seized methamphetamine samples. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  7. The Gulf Long-Term Follow-Up Study (GuLF STUDY): Biospecimen collection at enrollment.

    PubMed

    Engel, Lawrence S; Kwok, Richard K; Miller, Aubrey K; Blair, Aaron; Curry, Matthew D; McGrath, John A; Sandler, Dale P

    2017-01-01

    The 2010 Deepwater Horizon (DWH) explosion in the Gulf of Mexico led to the largest ever marine oil spill by volume. The GuLF STUDY is investigating possible adverse human health effects associated with oil spill activities. One objective of the study was to utilize biological specimens from study participants to examine spill-related adverse health effects. This study describes the methods for collecting, processing, shipping, and storing specimens during the enrollment phase of the study. GuLF STUDY participants living in Gulf States (Alabama, Florida, Louisiana, Mississippi, and eastern Texas) were eligible to complete a home visit at enrollment, one to three years after the DWH explosion. During this visit, blood, urine, toenail and hair clippings, and house dust samples were collected. Specimens were shipped overnight to a central processing laboratory in containers with cold and ambient temperature compartments. Most blood and urine specimens were then aliquoted and stored in liquid nitrogen vapor or at -80°C, with some samples stored at -20°C. A total of 11,193 participants completed a home visit, and over 99% provided at least one biospecimen. Most participants provided blood (93%), urine (99%), and toenail clippings (89%), and 40% provided hair. Nearly all participants (95%) provided house-dust samples. Most samples were received by the laboratory one (58%) or two (25%) days after collection. These biospecimens enable investigation of a range of biomarkers of spill-related adverse health effects, and possibly some biomarkers of spill-related exposures. The biospecimen collection, handling, and storage protocols were designed to maximize current and future scientific value within logistical and budgetary constraints and might serve as a template for future studies conducted in similar time-critical and geographically dispersed settings.

  8. Collection methods and quality assessment for Esche-richia coli, water quality, and microbial source tracking data within Tumacácori National Historical Park and the upper Santa Cruz River, Arizona, 2015-16

    USGS Publications Warehouse

    Paretti, Nicholas; Coes, Alissa L.; Kephart, Christopher M.; Mayo, Justine

    2018-03-05

    Tumacácori National Historical Park protects the culturally important Mission, San José de Tumacácori, while also managing a portion of the ecologically diverse riparian corridor of the Santa Cruz River. This report describes the methods and quality assurance procedures used in the collection of water samples for the analysis of Escherichia coli (E. coli), microbial source tracking markers, suspended sediment, water-quality parameters, turbidity, and the data collection for discharge and stage; the process for data review and approval is also described. Finally, this report provides a quantitative assessment of the quality of the E. coli, microbial source tracking, and suspended sediment data.The data-quality assessment revealed that bias attributed to field and laboratory contamination was minimal, with E. coli detections in only 3 out of 33 field blank samples analyzed. Concentrations in the field blanks were several orders of magnitude lower than environmental concentrations. The microbial source tracking (MST) field blank was below the detection limit for all MST markers analyzed. Laboratory blanks for E. coli at the USGS Arizona Water Science Center and laboratory blanks for MST markers at the USGS Ohio Water Microbiology Laboratory were all below the detection limit. Irreplicate data for E. coli and suspended sediment indicated that bias was not introduced to the data by combining samples collected using discrete sampling methods with samples collected using automatic sampling methods.The split and sequential E. coli replicate data showed consistent analytical variability and a single equation was developed to explain the variability of E. coli concentrations. An additional analysis of analytical variability for E. coli indicated analytical variability around 18 percent relative standard deviation and no trend was observed in the concentration during the processing and analysis of multiple split-replicates. Two replicate samples were collected for MST and individual markers were compared for a base flow and flood sample. For the markers found in common between the two types of samples, the relative standard deviation for the base flow sample was more than 3 times greater than the markers in the flood sample. Sequential suspended sediment replicates had a relative standard deviation of about 1.3 percent, indicating that environmental and analytical variability was minimal.A holding time review and laboratory study analysis supported the extended holding times required for this investigation. Most concentrations for flood and base-flow samples were within the theoretical variability specified in the most probable number approach suggesting that extended hold times did not overly influence the final concentrations reported.

  9. Capture and exploration of sample quality data to inform and improve the management of a screening collection.

    PubMed

    Charles, Isabel; Sinclair, Ian; Addison, Daniel H

    2014-04-01

    A new approach to the storage, processing, and interrogation of the quality data for screening samples has improved analytical throughput and confidence and enhanced the opportunities for learning from the accumulating records. The approach has entailed the design, development, and implementation of a database-oriented system, capturing information from the liquid chromatography-mass spectrometry capabilities used for assessing the integrity of samples in AstraZeneca's screening collection. A Web application has been developed to enable the visualization and interactive annotation of the analytical data, monitor the current sample queue, and report the throughput rate. Sample purity and identity are certified automatically on the chromatographic peaks of interest if predetermined thresholds are reached on key parameters. Using information extracted in parallel from the compound registration and container inventory databases, the chromatographic and spectroscopic profiles for each vessel are linked to the sample structures and storage histories. A search engine facilitates the direct comparison of results for multiple vessels of the same or similar compounds, for single vessels analyzed at different time points, or for vessels related by their origin or process flow. Access to this network of information has provided a deeper understanding of the multiple factors contributing to sample quality assurance.

  10. Effects of Anticoagulant, Processing Delay, and Assay Method (Branched DNA versus Reverse Transcriptase PCR) on Measurement of Human Immunodeficiency Virus Type 1 RNA Levels in Plasma

    PubMed Central

    Kirstein, Lynn M.; Mellors, John W.; Rinaldo, Charles R.; Margolick, Joseph B.; Giorgi, Janis V.; Phair, John P.; Dietz, Edith; Gupta, Phalguni; Sherlock, Christopher H.; Hogg, Robert; Montaner, J. S. G.; Muñoz, Alvaro

    1999-01-01

    We conducted two studies to determine the potential influence of delays in blood processing, type of anticoagulant, and assay method on human immunodeficiency virus type 1 (HIV-1) RNA levels in plasma. The first was an experimental study in which heparin- and EDTA-anticoagulated blood samples were collected from 101 HIV-positive individuals and processed to plasma after delays of 2, 6, and 18 h. HIV-1 RNA levels in each sample were then measured by both branched-DNA (bDNA) and reverse transcriptase PCR (RT-PCR) assays. Compared to samples processed within 2 h, the loss (decay) of HIV-1 RNA in heparinized blood was significant (P < 0.05) but small after 6 h (bDNA assay, −0.12 log10 copies/ml; RT-PCR, −0.05 log10 copies/ml) and after 18 h (bDNA assay, −0.27 log10 copies/ml; RT-PCR, −0.15 log10 copies/ml). Decay in EDTA-anticoagulated blood was not significant after 6 h (bDNA assay, −0.002 log10 copies/ml; RT-PCR, −0.02 log10 copies/ml), but it was after 18 h (bDNA assay, −0.09 log10 copies/ml; RT-PCR, −0.09 log10 copies/ml). Only 4% of samples processed after 6 h lost more than 50% (≥0.3 log10 copies/ml) of the HIV-1 RNA, regardless of the anticoagulant or the assay that was used. The second study compared HIV-1 RNA levels in samples from the Multicenter AIDS Cohort Study (MACS; samples were collected in heparin-containing tubes in 1985, had a 6-h average processing delay, and were assayed by bDNA assay) and the British Columbia Drug Treatment Program (BCDTP) (collected in EDTA- or acid citrate dextrose-containing tubes in 1996 and 1997, had a 2-h maximum processing delay, and were assayed by RT-PCR). HIV-1 RNA levels in samples from the two cohorts were not significantly different after adjusting for CD4+-cell count and converting bDNA assay values to those corresponding to the RT-PCR results. In summary, the decay of HIV-1 RNA measured in heparinized blood after 6 h was small (−0.05 to −0.12 log10 copies/ml), and the minor impact of this decay on HIV-1 RNA concentrations in archived plasma samples of the MACS was confirmed by the similarity of CD4+-cell counts and assay-adjusted HIV-1 RNA concentrations in the MACS and BCDTP. PMID:10405379

  11. Protein blotting protocol for beginners.

    PubMed

    Petrasovits, Lars A

    2014-01-01

    The transfer and immobilization of biological macromolecules onto solid nitrocellulose or nylon (polyvinylidene difluoride (PVDF)) membranes subsequently followed by specific detection is referred to as blotting. DNA blots are called Southerns after the inventor of the technique, Edwin Southern. By analogy, RNA blots are referred to as northerns and protein blots as westerns (Burnette, Anal Biochem 112:195-203, 1981). With few exceptions, western blotting involves five steps, namely, sample collection, preparation, separation, immobilization, and detection. In this chapter, protocols for the entire process from sample collection to detection are described.

  12. Collection, transport and general processing of clinical specimens in Microbiology laboratory.

    PubMed

    Sánchez-Romero, M Isabel; García-Lechuz Moya, Juan Manuel; González López, Juan José; Orta Mira, Nieves

    2018-02-06

    The interpretation and the accuracy of the microbiological results still depend to a great extent on the quality of the samples and their processing within the Microbiology laboratory. The type of specimen, the appropriate time to obtain the sample, the way of sampling, the storage and transport are critical points in the diagnostic process. The availability of new laboratory techniques for unusual pathogens, makes necessary the review and update of all the steps involved in the processing of the samples. Nowadays, the laboratory automation and the availability of rapid techniques allow the precision and turn-around time necessary to help the clinicians in the decision making. In order to be efficient, it is very important to obtain clinical information to use the best diagnostic tools. Copyright © 2018 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  13. Cost Factors in Scaling in SfM Collections and Processing Solutions

    NASA Astrophysics Data System (ADS)

    Cherry, J. E.

    2015-12-01

    In this talk I will discuss the economics of scaling Structure from Motion (SfM)-style collections from 1 km2 and below to 100's and 1000's of square kilometers. Considerations include the costs of the technical equipment: comparisons of small, medium, and large-format camera systems, as well as various GPS-INS systems and their impact on processing accuracy for various Ground Sampling Distances. Tradeoffs between camera formats and flight time are central. Weather conditions and planning high altitude versus low altitude flights are another economic factor, particularly in areas of persistently bad weather and in areas where ground logistics (i.e. hotel rooms and pilot incidentals) are expensive. Unique costs associated with UAS collections and experimental payloads will be discussed. Finally, the costs of equipment and labor differs in SfM processing than in conventional orthomosaic and LiDAR processing. There are opportunities for 'economies of scale' in SfM collections under certain circumstances but whether the accuracy specifications are firm/fixed or 'best effort' makes a difference.

  14. Mercury in fish and macroinvertebrates from New York's streams and rivers: A compendium of data sources

    USGS Publications Warehouse

    Riva-Murray, Karen; Burns, Douglas A.

    2016-01-01

    The U.S. Geological Survey has compiled a list of existing data sets, from selected sources, containing mercury (Hg) concentration data in fish and macroinvertebrate samples that were collected from flowing waters of New York State from 1970 through 2014. Data sets selected for inclusion in this report were limited to those that contain fish and (or) macroinvertebrate data that were collected across broad areas, cover relatively long time periods, and (or) were collected as part of a broader-scale (e.g. national) study or program. In addition, all data sets listed were collected, processed, and analyzed with documented methods, and contain critical sample information (e.g. fish species, fish size, Hg species) that is needed to analyze and interpret the reported Hg concentration data. Fourteen data sets, all from state or federal agencies, are listed in this report, along with selected descriptive information regarding each data source and data set contents. Together, these 14 data sets contain Hg and related data for more than 7,000 biological samples collected from more than 700 unique stream and river locations between 1970 and 2014.

  15. Biobanking of different body fluids within the frame of IVF-a standard operating procedure to improve reproductive biology research.

    PubMed

    Schenk, Michael; Huppertz, Berthold; Obermayer-Pietsch, Barbara; Kastelic, Darja; Hörmann-Kröpfl, Martina; Weiss, Gregor

    2017-02-01

    The aim of the present study was to develop a standard operating procedure (SOP) for the collection, transport, and storage of human cumulus cells, follicular fluid, blood serum, seminal plasma, embryo culture supernatant, and embryo culture supernatant control obtained within the IVF process under approved protocols and written informed consent from participating patients. The SOP was developed at the Kinderwunsch Institut Schenk, Dobl, Austria, together with Biobank Graz of the Medical University of Graz, Austria. The SOP provides comprehensive details of laboratory procedures and sampling of the different fluids within the IVF process. Furthermore, information on sample coding, references of involved laboratory techniques (e.g., oocyte retrieval with a Steiner-TAN needle), ethical approvals, and biobanking procedures are presented. The result of the present study is a standard operating procedure. The SOP ensures a professional way for collection and scientific use of IVF samples by the Kinderwunsch Institut Schenk, Dobl, Austria, and Biobank Graz of the Medical University of Graz, Austria. It can be used as a template for other institutions to unify specimen collection procedures in the field of reproductive health research.

  16. Environmental DNA sampling protocol - filtering water to capture DNA from aquatic organisms

    USGS Publications Warehouse

    Laramie, Matthew B.; Pilliod, David S.; Goldberg, Caren S.; Strickler, Katherine M.

    2015-09-29

    Environmental DNA (eDNA) analysis is an effective method of determining the presence of aquatic organisms such as fish, amphibians, and other taxa. This publication is meant to guide researchers and managers in the collection, concentration, and preservation of eDNA samples from lentic and lotic systems. A sampling workflow diagram and three sampling protocols are included as well as a list of suggested supplies. Protocols include filter and pump assembly using: (1) a hand-driven vacuum pump, ideal for sample collection in remote sampling locations where no electricity is available and when equipment weight is a primary concern; (2) a peristaltic pump powered by a rechargeable battery-operated driver/drill, suitable for remote sampling locations when weight consideration is less of a concern; (3) a 120-volt alternating current (AC) powered peristaltic pump suitable for any location where 120-volt AC power is accessible, or for roadside sampling locations. Images and detailed descriptions are provided for each step in the sampling and preservation process.

  17. Demonstration of the Attributes of Multi-increment Sampling and Proper Sample Processing Protocols for the Characterization of Metals on DoD Facilities

    DTIC Science & Technology

    2013-06-01

    lenses of unconsolidated sand and rounded river gravel overlain by as much as 5 m of silt. Gravel consists mostly of quartz and metamorphic rock with...iii LIST OF FIGURES Page Figure 1. Example of multi-increment sampling using a systematic-random sampling design for collecting two separate...The small arms firing Range 16 Record berms at Fort Wainwright. .................... 25 Figure 9. Location of berms sampled using ISM and grab

  18. Blood meal analysis of tabanid fly after it biting the rare Sumatran rhinoceros.

    PubMed

    Rovie-Ryan, Jeffrine Japning; Zainuddin, Zainal Zahari; Marni, Wahap; Ahmad, Abdul Hamid; Ambu, Laurentius N; Payne, Junaidi

    2013-02-01

    To demonstrate a noninvasive large mammalian genetic sampling method using blood meal obtained from a tabanid fly. Blood meal was recovered from the abdomen of an engorged tabanid fly (Haematopota sp.) which was captured immediately after biting a Sumatran rhino in captivity. The blood was applied on to a Whatman FTA(®) blood card. Subsequent laboratory work was conducted to extract, amplify and sequence the DNA from the sample. Validation was done by sampling the hair follicles and blood samples from the rhinoceros and subjecting it to the same laboratory process. BLAST search and constructed phylogenetic trees confirmed the blood meal samples were indeed from the rhino. This method could be used in the field application to noninvasively collect genetic samples. Collection of tabanids and other haematophagous arthropods (e.g. mosquitoes and ticks) and other blood-sucking parasites (e.g. leeches and worms) could also provide information on vector-borne diseases.

  19. Fixation filter, device for the rapid in situ preservation of particulate samples

    NASA Astrophysics Data System (ADS)

    Taylor, C. D.; Edgcomb, V. P.; Doherty, K. W.; Engstrom, I.; Shanahan, T.; Pachiadaki, M. G.; Molyneaux, S. J.; Honjo, S.

    2015-02-01

    Niskin bottle rosettes have for years been the workhorse technology for collection of water samples used in biological and chemical oceanography. Studies of marine microbiology and biogeochemical cycling that aim to analyze labile organic molecules including messenger RNA, must take into account factors associated with sampling methodology that obscure an accurate picture of in situ activities/processes. With Niskin sampling, the large and often variable times between sample collection and preservation on deck of a ship, and the sometimes significant physico-chemical changes (e.g., changes in pressure, light, temperature, redox state, etc.) that water samples and organisms are exposed to, are likely to introduce artifacts. These concerns are likely more significant when working with phototrophs, deep-sea microbes, and/or organisms inhabiting low-oxygen or anoxic environments. We report here the development of a new technology for the in situ collection and chemical preservation of particulate microbial samples for a variety of downstream analyses depending on preservative choice by the user. The Fixation Filter Unit, version 3 (FF3) permits filtration of water sample through 47 mm diameter filters of the user's choice and upon completion of filtration, chemically preserves the retained sample within 10's of seconds. The stand-alone devices can be adapted to hydrocasting or mooring-based platforms.

  20. Emotional Intelligence and Life Adjustment for Nigerian Secondary Students

    ERIC Educational Resources Information Center

    Ogoemeka, Obioma Helen

    2013-01-01

    In the process of educating adolescents, good emotional development and life adjustment are two significant factors for teachers to know. This study employed random cluster sampling of senior secondary school students in Ondo and Oyo States in south-western Nigeria. The Random sampling was employed to select 1,070 students. The data collected were…

  1. Compositional Data for Bengal Delta Sediment Collected from a Borehole at Rajoir, Bangladesh

    USGS Publications Warehouse

    Breit, George N.; Yount, James C.; Uddin, Md. Nehal; Muneem, Ad. Atual; Lowers, Heather; Berry, Cyrus J.; Whitney, John W.

    2007-01-01

    Processes active within sediment of the Bengal basin have attracted world concern because of the locally high content of arsenic dissolved in ground water drawn from that sediment. Sediment samples were collected from a borehole in the town of Rajoir, Rajoir upazila, Madaripur district, Bangladesh, to investigate the processes contributing to arsenic contamination. The samples were mineralogically and chemically analyzed to determine compositional variations related to the arsenic content of the sediment. Mineralogy of the sediment was determined using powder X-ray diffraction. Bulk chemical composition was measured by Combustion; Inductively Coupled Plasma Atomic Emission Spectroscopy; Energy Dispersive X-ray Fluorescence; and Hydride Generation Atomic Absorption Spectrophotometry. Sediment was treated with 0.5 N HCl and resulting solutions were analyzed, primarily to evaluate the abundance and oxidation state of acid-soluble iron. Acid-volatile sulfide, acid-soluble sulfate, and reducible sulfide were also measured on a few samples. Sediment sampled at Rajoir is typically unlithified, gray, micaceous, feldspathic arenaceous sand with a few silt and clay layers. Arsenic content of the sediment ranges from 0.6 to 21 ppm with a median of 1.2 ppm.

  2. National Household Education Survey of 1993. School Safety and Discipline Data File User's Manual.

    ERIC Educational Resources Information Center

    Brick, J. Michael; And Others

    This manual provides documentation and guidance for users of the public release data file for the School Safety and Discipline component of the 1993 National Household Education Survey (NHES:93). Information about the purpose of the study, the data collection instruments, the sample design, and data collection and processing is presented. The…

  3. Occurrence and change of estrogenic activity in the process of drinking water treatment and distribution.

    PubMed

    Xiao, Sanhua; Lv, Xuemin; Lu, Yi; Yang, Xiaoming; Dong, Xiaorong; Ma, Kunpeng; Zeng, Yifan; Jin, Tao; Tang, Fei

    2016-09-01

    From 2010 to 2012, the Yangtze River and Hanjiang River (Wuhan section) were monitored for estrogenic activities during various water level periods. Using a recombinant yeast estrogen screen (YES) assay, 54 water samples were evaluated over the course of nine sampling campaigns. The mean 17β-estradiol equivalent (EEQ) value of raw water from the Yangtze River was 0-5.20 ng/L; and the EEQ level from the Hanjiang River was 0-3.22 ng/L. In Wuhan, drinking water treatment plants (DWTPs) using conventional treatments reduced estrogenic activities by more than 89 %. In general, water samples collected during the level period showed weaker estrogenic activities compared to those collected during the dry period. The samples collected in 2010 showed the strongest estrogenic activities of the 3-year period. The lack of correlations between estrogenic activities and selected common water quality parameters showed that estrogenic activity cannot be tied to common water quality parameters.

  4. Secondary Aluminum Processing Waste: Salt Cake Characterization and Reactivity

    EPA Science Inventory

    Thirty-nine salt cake samples were collected from 10 SAP facilities across the U.S. The facilities were identified by the Aluminum Association to cover a wide range of processes. Results suggest that while the percent metal leached from the salt cake was relatively low, the leac...

  5. Conceptual Level of Understanding about Sound Concept: Sample of Fifth Grade Students

    ERIC Educational Resources Information Center

    Bostan Sarioglan, Ayberk

    2016-01-01

    In this study, students' conceptual change processes related to the sound concept were examined. Study group was comprises of 325 fifth grade middle school students. Three multiple-choice questions were used as the data collection tool. At the data analysis process "scientific response", "scientifically unacceptable response"…

  6. Laboratory evaluation of a protocol for personal sampling of airborne particles in welding and allied processes.

    PubMed

    Chung, K Y; Carter, G J; Stancliffe, J D

    1999-02-01

    A new European/International Standard (ISOprEN 10882-1) on the sampling of airborne particulates generated during welding and allied processes has been proposed. The use of a number of samplers and sampling procedures is allowable within the defined protocol. The influence of these variables on welding fume exposures measured during welding and grinding of stainless and mild steel using the gas metal arc (GMA) and flux-cored arc (FCA) and GMA welding of aluminium has been examined. Results show that use of any of the samplers will not give significantly different measured exposures. The effect on exposure measurement of placing the samplers on either side of the head was variable; consequently, sampling position cannot be meaningfully defined. All samplers collected significant amounts of grinding dust. Therefore, gravimetric determination of welding fume exposure in atmospheres containing grinding dust will be inaccurate. The use of a new size selective sampler can, to some extent, be used to give a more accurate estimate of exposure. The reliability of fume analysis data of welding consumables has caused concern; and the reason for differences that existed between the material safety data sheet and the analysis of fume samples collected requires further investigation.

  7. Geochemical data for Colorado soils-Results from the 2006 state-scale geochemical survey

    USGS Publications Warehouse

    Smith, David B.; Ellefsen, Karl J.; Kilburn, James E.

    2010-01-01

    In 2006, soil samples were collected at 960 sites (1 site per 280 square kilometers) throughout the state of Colorado. These samples were collected from a depth of 0-15 centimeters and, following a near-total multi-acid digestion, were analyzed for a suite of more than 40 major and trace elements. The resulting data set provides a baseline for the natural variation in soil geochemistry for Colorado and forms the basis for detecting changes in soil composition that might result from natural processes or anthropogenic activities. This report describes the sampling and analytical protocols used and makes available all the soil geochemical data generated in the study.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barrett, Christopher A.; Martinez, Alonzo; McNamara, Bruce K.

    International Atom Energy Agency (IAEA) safeguard verification measures in gaseous centrifuge enrichment plants (GCEPs) rely on environmental sampling, non-destructive assay (NDA), and destructive assay (DA) sampling and analysis to determine uranium enrichment. UF6 bias defect measurements are made by DA sampling and analysis to assure that enrichment is consistent with declarations. DA samples are collected from a limited number of cylinders for high precision, offsite mass spectrometer analysis. Samples are typically drawn from a sampling tap into a UF6 sample bottle, then packaged, sealed, and shipped under IAEA chain of custody to an offsite analytical laboratory. Future DA safeguard measuresmore » may require improvements in efficiency and effectiveness as GCEP capacities increase and UF6 shipping regulations become increasingly more restrictive. The Pacific Northwest National Laboratory (PNNL) DA sampler concept and Laser Ablation Absorption Ratio Spectrometry (LAARS) assay method are under development to potentially provide DA safeguard tools that increase inspection effectiveness and reduce sample shipping constraints. The PNNL DA sampler concept uses a handheld sampler to collect DA samples for either onsite LAARS assay or offsite laboratory analysis. The DA sampler design will use a small sampling planchet that is coated with an adsorptive film to collect controlled quantities of UF6 gas directly from a cylinder or process sampling tap. Development efforts are currently underway at PNNL to enhance LAARS assay performance to allow high-precision onsite bias defect measurements. In this paper, we report on the experimental investigation to develop adsorptive films for the PNNL DA sampler concept. These films are intended to efficiently capture UF6 and then stabilize the collected DA sample prior to onsite LAARS or offsite laboratory analysis. Several porous material composite films were investigated, including a film designed to maximize the chemical adsorption and binding of gaseous UF6 onto the sampling planchet.« less

  9. Impact of collection conditions on the metabolite content of human urine samples as analyzed by liquid chromatography coupled to mass spectrometry and nuclear magnetic resonance spectroscopy.

    PubMed

    Roux, Aurélie; Thévenot, Etienne A; Seguin, François; Olivier, Marie-Françoise; Junot, Christophe

    There is a lack of comprehensive studies documenting the impact of sample collection conditions on metabolic composition of human urine. To address this issue, two experiments were performed at a 3-month interval, in which midstream urine samples from healthy individuals were collected, pooled, divided into several aliquots and kept under specific conditions (room temperature, 4 °C, with or without preservative) up to 72 h before storage at -80 °C. Samples were analyzed by high-performance liquid chromatography coupled to high-resolution mass spectrometry and bacterial contamination was monitored by turbidimetry. Multivariate analyses showed that urinary metabolic fingerprints were affected by the presence of preservatives and also by storage at room temperature from 24 to 72 h, whereas no change was observed for urine samples stored at 4 °C over a 72-h period. Investigations were then focused on 280 metabolites previously identified in urine: 19 of them were impacted by the kind of sample collection protocol in both experiments, including 12 metabolites affected by bacterial contamination and 7 exhibiting poor chemical stability. Finally, our results emphasize that the use of preservative prevents bacterial overgrowth, but does not avoid metabolite instability in solution, whereas storage at 4 °C inhibits bacterial overgrowth at least over a 72-h period and slows the chemical degradation process. Consequently, and for further LC/MS analyses, human urine samples should be kept at 4 °C if their collection is performed over 24 h.

  10. Geochemical and radiological characterization of soils from former radium processing sites

    USGS Publications Warehouse

    Landa, E.R.

    1984-01-01

    Soil samples were collected from former radium processing sites in Denver, CO, and East Orange, NJ. Particle-size separations and radiochemical analyses of selected samples showed that while the greatest contents of both 226Ra and U were generally found in the finest (< 45 ??m) fraction, the pattern was not always of progressive increase in radionuclide content with decreasing particle size. Leaching tests on these samples showed a large portion of the 225Ra and U to be soluble in dilute hydrochloric acid. Radon-emanation coefficients measured for bulk samples of contaminated soil were about 20%. Recovery of residual uranium and vanadium, as an adjunct to any remedial action program, appears unlikely due to economic considerations.

  11. Apollo-11 lunar sample information catalogue

    NASA Technical Reports Server (NTRS)

    Kramer, F. E. (Compiler); Twedell, D. B. (Compiler); Walton, W. J. A., Jr. (Compiler)

    1977-01-01

    The Apollo 11 mission is reviewed with emphasis on the collection of lunar samples, their geologic setting, early processing, and preliminary examination. The experience gained during five subsequent missions was applied to obtain physical-chemical data for each sample using photographic and binocular microscope techniques. Topics discussed include: binocular examination procedure; breccia clast dexrriptuons, thin section examinations procedure typical breccia in thin section, typical basalt in thin section, sample histories, and chemical and age data. An index to photographs is included.

  12. Database of the United States Coal Pellet Collection of the U.S. Geological Survey Organic Petrology Laboratory

    USGS Publications Warehouse

    Deems, Nikolaus J.; Hackley, Paul C.

    2012-01-01

    The Organic Petrology Laboratory (OPL) of the U.S. Geological Survey (USGS) Eastern Energy Resources Science Center in Reston, Virginia, contains several thousand processed coal sample materials that were loosely organized in laboratory drawers for the past several decades. The majority of these were prepared as 1-inch-diameter particulate coal pellets (more than 6,000 pellets; one sample usually was prepared as two pellets, although some samples were prepared in as many as four pellets), which were polished and used in reflected light petrographic studies. These samples represent the work of many scientists from the 1970s to the present, most notably Ron Stanton, who managed the OPL until 2001 (see Warwick and Ruppert, 2005, for a comprehensive bibliography of Ron Stanton's work). The purpose of the project described herein was to organize and catalog the U.S. part of the petrographic sample collection into a comprehensive database (available with this report as a Microsoft Excel file) and to compile and list published studies associated with the various sample sets. Through this work, the extent of the collection is publicly documented as a resource and sample library available to other scientists and researchers working in U.S. coal basins previously studied by organic petrologists affiliated with the USGS. Other researchers may obtain samples in the OPL collection on loan at the discretion of the USGS authors listed in this report and its associated Web page.

  13. Efficiently sampling conformations and pathways using the concurrent adaptive sampling (CAS) algorithm

    NASA Astrophysics Data System (ADS)

    Ahn, Surl-Hee; Grate, Jay W.; Darve, Eric F.

    2017-08-01

    Molecular dynamics simulations are useful in obtaining thermodynamic and kinetic properties of bio-molecules, but they are limited by the time scale barrier. That is, we may not obtain properties' efficiently because we need to run microseconds or longer simulations using femtosecond time steps. To overcome this time scale barrier, we can use the weighted ensemble (WE) method, a powerful enhanced sampling method that efficiently samples thermodynamic and kinetic properties. However, the WE method requires an appropriate partitioning of phase space into discrete macrostates, which can be problematic when we have a high-dimensional collective space or when little is known a priori about the molecular system. Hence, we developed a new WE-based method, called the "Concurrent Adaptive Sampling (CAS) algorithm," to tackle these issues. The CAS algorithm is not constrained to use only one or two collective variables, unlike most reaction coordinate-dependent methods. Instead, it can use a large number of collective variables and adaptive macrostates to enhance the sampling in the high-dimensional space. This is especially useful for systems in which we do not know what the right reaction coordinates are, in which case we can use many collective variables to sample conformations and pathways. In addition, a clustering technique based on the committor function is used to accelerate sampling the slowest process in the molecular system. In this paper, we introduce the new method and show results from two-dimensional models and bio-molecules, specifically penta-alanine and a triazine trimer.

  14. Source apportionment of methane using a triple isotope approach - Method development and application in the Baltic Sea

    NASA Astrophysics Data System (ADS)

    Steinbach, Julia; Holmstrand, Henry; Semiletov, Igor; Shakhova, Natalia; Shcherbakova, Kseniia; Kosmach, Denis; Sapart, Célia J.; Gustafsson, Örjan

    2015-04-01

    We present a method for measurements of the stable and radiocarbon isotope systems of methane in seawater and sediments. The triple isotope characterization of methane is useful in distinguishing different sources and for improving our understanding of biogeochemical processes affecting methane in the water column. D14C-CH4 is an especially powerful addition to stable isotope analyses in distinguishing between thermogenic and biogenic origins of the methane. Such measurements require large sample sizes, due to low natural abundance of the radiocarbon in CH4. Our system for sample collection, methane extraction and purification builds on the approach by Kessler and Reeburgh (Limn. & Ocean. Meth., 2005). An in-field system extracts methane from 30 -120 l water or 1-2 l sediment (depending on the in-situ methane concentration) by purging the samples with Helium to transfer the dissolved methane to the headspace and circulating it through cryogenically cooled absorbent traps where methane is collected. The in-field preparation eliminates the risks of storage and transport of large seawater quantities and subsequent leakage of sample gas as well as ongoing microbial processes and chemical reactions that may alter the sample composition. In the subsequent shore-based treatment, a laboratory system is used to purify and combust the collected CH4 to AMS-amenable CO2. Subsamples from the methane traps are analyzed for stable isotopes and compared to stable isotope measurements directly measured from small water samples taken in parallel, to correct for any potential fractionation occurring during this process. The system has been successfully tested and used on several shorter shipboard expeditions in the Baltic Sea and on a long summer expedition across the Arctic Ocean. Here we present the details of the method and testing, as well as first triple isotope field data from two cruises to the Landsort Deep area in the Central Baltic Sea.

  15. Metagenomic survey of bacterial diversity in the atmosphere of Mexico City using different sampling methods.

    PubMed

    Serrano-Silva, N; Calderón-Ezquerro, M C

    2018-04-01

    The identification of airborne bacteria has traditionally been performed by retrieval in culture media, but the bacterial diversity in the air is underestimated using this method because many bacteria are not readily cultured. Advances in DNA sequencing technology have produced a broad knowledge of genomics and metagenomics, which can greatly improve our ability to identify and study the diversity of airborne bacteria. However, researchers are facing several challenges, particularly the efficient retrieval of low-density microorganisms from the air and the lack of standardized protocols for sample collection and processing. In this study, we tested three methods for sampling bioaerosols - a Durham-type spore trap (Durham), a seven-day recording volumetric spore trap (HST), and a high-throughput 'Jet' spore and particle sampler (Jet) - and recovered metagenomic DNA for 16S rDNA sequencing. Samples were simultaneously collected with the three devices during one week, and the sequencing libraries were analyzed. A simple and efficient method for collecting bioaerosols and extracting good quality DNA for high-throughput sequencing was standardized. The Durham sampler collected preferentially Cyanobacteria, the HST Actinobacteria, Proteobacteria and Firmicutes, and the Jet mainly Proteobacteria and Firmicutes. The HST sampler collected the largest amount of airborne bacterial diversity. More experiments are necessary to select the right sampler, depending on study objectives, which may require monitoring and collecting specific airborne bacteria. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Indicator organisms in meat and poultry slaughter operations: their potential use in process control and the role of emerging technologies.

    PubMed

    Saini, Parmesh K; Marks, Harry M; Dreyfuss, Moshe S; Evans, Peter; Cook, L Victor; Dessai, Uday

    2011-08-01

    Measuring commonly occurring, nonpathogenic organisms on poultry products may be used for designing statistical process control systems that could result in reductions of pathogen levels. The extent of pathogen level reduction that could be obtained from actions resulting from monitoring these measurements over time depends upon the degree of understanding cause-effect relationships between processing variables, selected output variables, and pathogens. For such measurements to be effective for controlling or improving processing to some capability level within the statistical process control context, sufficiently frequent measurements would be needed to help identify processing deficiencies. Ultimately the correct balance of sampling and resources is determined by those characteristics of deficient processing that are important to identify. We recommend strategies that emphasize flexibility, depending upon sampling objectives. Coupling the measurement of levels of indicator organisms with practical emerging technologies and suitable on-site platforms that decrease the time between sample collections and interpreting results would enhance monitoring process control.

  17. Uncertainty assessment method for the Cs-137 fallout inventory and penetration depth.

    PubMed

    Papadakos, G N; Karangelos, D J; Petropoulos, N P; Anagnostakis, M J; Hinis, E P; Simopoulos, S E

    2017-05-01

    Within the presented study, soil samples were collected in year 2007 at 20 different locations of the Greek terrain, both from the surface and also from depths down to 26 cm. Sampling locations were selected primarily from areas where high levels of 137 Cs deposition after the Chernobyl accident had already been identified by the Nuclear Engineering Laboratory of the National Technical University of Athens during and after the year of 1986. At one location of relatively higher deposition, soil core samples were collected following a 60 m by 60 m Cartesian grid with a 20 m node-to-node distance. Single or pair core samples were also collected from the remaining 19 locations. Sample measurements and analysis were used to estimate 137 Cs inventory and the corresponding depth migration, twenty years after the deposition on Greek terrain. Based on these data, the uncertainty components of the whole sampling-to-results procedure were investigated. A cause-and-effect assessment process was used to apply the law of error propagation and demonstrate that the dominating significant component of the combined uncertainty is that due to the spatial variability of the contemporary (2007) 137 Cs inventory. A secondary, yet also significant component was identified to be the activity measurement process itself. Other less-significant uncertainty parameters were sampling methods, the variation in the soil field density with depth and the preparation of samples for measurement. The sampling grid experiment allowed for the quantitative evaluation of the uncertainty due to spatial variability, also by the assistance of the semivariance analysis. Denser, optimized grid could return more accurate values for this component but with a significantly elevated laboratory cost, in terms of both, human and material resources. Using the hereby collected data and for the case of a single core soil sampling using a well-defined sampling methodology quality assurance, the uncertainty component due to spatial variability was evaluated to about 19% for the 137 Cs inventory and up to 34% for the 137 Cs penetration depth. Based on the presented results and also on related literature, it is argued that such high uncertainties should be anticipated for single core samplings conducted using similar methodology and employed as 137 Cs inventory and penetration depth estimators. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Actual Waste Demonstration of the Nitric-Glycolic Flowsheet for Sludge Batch 9 Qualification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. D. Newell; Pareizs, J. M.; Martino, C. J.

    For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) performs qualification testing to demonstrate that the sludge batch is processable. Testing performed by the Savannah River National Laboratory has shown glycolic acid to be effective in replacing the function of formic acid in the DWPF chemical process. The nitric-glycolic flowsheet reduces mercury, significantly lowers the catalytic generation of hydrogen and ammonia which could allow purge reduction in the Sludge Receipt and Adjustment Tank (SRAT), stabilizes the pH and chemistry in the SRAT and the Slurry Mix Evaporator (SME), allowsmore » for effective rheology adjustment, and is favorable with respect to melter flammability. In order to implement the new flowsheet, SRAT and SME cycles, designated SC-18, were performed using a Sludge Batch (SB) 9 slurry blended from SB8 Tank 40H and Tank 51H samples. The SRAT cycle involved adding nitric and glycolic acids to the sludge, refluxing to steam strip mercury, and dewatering to a targeted solids concentration. Data collected during the SRAT cycle included offgas analyses, process temperatures, heat transfer, and pH measurements. The SME cycle demonstrated the addition of glass frit and the replication of six canister decontamination additions. The demonstration concluded with dewatering to a targeted solids concentration. Data collected during the SME cycle included offgas analyses, process temperatures, heat transfer, and pH measurements. Slurry and condensate samples were collected for subsequent analysis« less

  19. An Exploratory Investigation of the Periodic Performance Evaluation Processes for Marketing Faculty: A Comparison of Doctoral-Granting and Non-Doctoral-Granting Universities

    ERIC Educational Resources Information Center

    Shepherd, C. David; Carley, Susan S.; Stuart, Randy S.

    2009-01-01

    Whether a first entrant into the academic job market or a seasoned professional, career outcomes for marketing educators depend heavily on the evaluation process used at their institutions. This research explores the periodic performance evaluation process for marketing faculty members using data collected from a national sample of marketing…

  20. [Saarland Growth Study: sampling design].

    PubMed

    Danker-Hopfe, H; Zabransky, S

    2000-01-01

    The use of reference data to evaluate the physical development of children and adolescents is part of the daily routine in the paediatric ambulance. The construction of such reference data is based on the collection of extensive reference data. There are different kinds of reference data: cross sectional references, which are based on data collected from a big representative cross-sectional sample of the population, longitudinal references, which are based on follow-up surveys of usually smaller samples of individuals from birth to maturity, and mixed longitudinal references, which are a combination of longitudinal and cross-sectional reference data. The advantages and disadvantages of the different methods of data collection and the resulting reference data are discussed. The Saarland Growth Study was conducted for several reasons: growth processes are subject to secular changes, there are no specific reference data for children and adolescents from this part of the country and the growth charts in use in the paediatric praxis are possibly not appropriate any more. Therefore, the Saarland Growth Study served two purposes a) to create actual regional reference data and b) to create a database for future studies on secular trends in growth processes of children and adolescents from Saarland. The present contribution focusses on general remarks on the sampling design of (cross-sectional) growth surveys and its inferences for the design of the present study.

  1. Assessment of Normal Variability in Peripheral Blood Gene Expression

    DOE PAGES

    Campbell, Catherine; Vernon, Suzanne D.; Karem, Kevin L.; ...

    2002-01-01

    Peripheral blood is representative of many systemic processes and is an ideal sample for expression profiling of diseases that have no known or accessible lesion. Peripheral blood is a complex mixture of cell types and some differences in peripheral blood gene expression may reflect the timing of sample collection rather than an underlying disease process. For this reason, it is important to assess study design factors that may cause variability in gene expression not related to what is being analyzed. Variation in the gene expression of circulating peripheral blood mononuclear cells (PBMCs) from three healthy volunteers sampled three times onemore » day each week for one month was examined for 1,176 genes printed on filter arrays. Less than 1% of the genes showed any variation in expression that was related to the time of collection, and none of the changes were noted in more than one individual. These results suggest that observed variation was due to experimental variability.« less

  2. Quantitative assessment of anthrax vaccine immunogenicity using the dried blood spot matrix.

    PubMed

    Schiffer, Jarad M; Maniatis, Panagiotis; Garza, Ilana; Steward-Clark, Evelene; Korman, Lawrence T; Pittman, Phillip R; Mei, Joanne V; Quinn, Conrad P

    2013-03-01

    The collection, processing and transportation to a testing laboratory of large numbers of clinical samples during an emergency response situation present significant cost and logistical issues. Blood and serum are common clinical samples for diagnosis of disease. Serum preparation requires significant on-site equipment and facilities for immediate processing and cold storage, and significant costs for cold-chain transport to testing facilities. The dried blood spot (DBS) matrix offers an alternative to serum for rapid and efficient sample collection with fewer on-site equipment requirements and considerably lower storage and transport costs. We have developed and validated assay methods for using DBS in the quantitative anti-protective antigen IgG enzyme-linked immunosorbent assay (ELISA), one of the primary assays for assessing immunogenicity of anthrax vaccine and for confirmatory diagnosis of Bacillus anthracis infection in humans. We have also developed and validated high-throughput data analysis software to facilitate data handling for large clinical trials and emergency response. Published by Elsevier Ltd.

  3. [Logistics of collection and transportation of biological samples and the organization of the central laboratory in the ELSA-Brasil].

    PubMed

    Fedeli, Ligia G; Vidigal, Pedro G; Leite, Claudia Mendes; Castilhos, Cristina D; Pimentel, Robércia Anjos; Maniero, Viviane C; Mill, Jose Geraldo; Lotufo, Paulo A; Pereira, Alexandre C; Bensenor, Isabela M

    2013-06-01

    The ELSA (Estudo Longitudinal de Saúde do Adulto - Brazilian Longitudinal Study for Adult Health) is a multicenter cohort study which aims at the identification of risk factors associated with type 2 diabetes and cardiovascular diseases in the Brazilian population. The paper describes the strategies for the collection, processing, transportation, and quality control of blood and urine tests in the ELSA. The study decided to centralize the tests at one single laboratory. The processing of the samples was performed at the local laboratories, reducing the weight of the material to be transported, and diminishing the costs of transportation to the central laboratory at the Universidade de São Paulo Hospital. The study included tests for the evaluation of diabetes, insulin resistance, dyslipidemia, electrolyte abnormalities, thyroid hormones, uric acid, hepatic enzyme abnormalities, inflammation, and total blood cell count. In addition, leukocyte DNA, urine, plasma and serum samples were stored. The central laboratory performed approximately 375,000 tests.

  4. Comprehensive characterisation of sewage sludge for thermochemical conversion processes - Based on Singapore survey.

    PubMed

    Chan, Wei Ping; Wang, Jing-Yuan

    2016-08-01

    Recently, sludge attracted great interest as a potential feedstock in thermochemical conversion processes. However, compositions and thermal degradation behaviours of sludge were highly complex and distinctive compared to other traditional feedstock led to a need of fundamental research on sludge. Comprehensive characterisation of sludge specifically for thermochemical conversion was carried out for all existing Water Reclamation Plants in Singapore. In total, 14 sludge samples collected based on the type, plant, and batch categorisation. Existing characterisation methods for physical and chemical properties were analysed and reviewed using the collected samples. Qualitative similarities and quantitative variations of different sludge samples were identified and discussed. Oxidation of inorganic in sludge during ash forming analysis found to be causing significant deviations on proximate and ultimate analysis. Therefore, alternative parameters and comparison basis including Fixed Residues (FR), Inorganic Matters (IM) and Total Inorganics (TI) were proposed for better understanding on the thermochemical characteristics of sludge. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Leaching of polycyclic aromatic hydrocarbons from oil shale processing waste deposit: a long-term field study.

    PubMed

    Jefimova, Jekaterina; Irha, Natalya; Reinik, Janek; Kirso, Uuve; Steinnes, Eiliv

    2014-05-15

    The leaching behavior of selected polycyclic aromatic hydrocarbons (PAHs) from an oil shale processing waste deposit was monitored during 2005-2009. Samples were collected from the deposit using a special device for leachate sampling at field conditions without disturbance of the upper layers. Contents of 16 priority PAHs in leachate samples collected from aged and fresh parts of the deposit were determined by GC-MS. The sum of the detected PAHs in leachates varied significantly throughout the study period: 19-315 μg/l from aged spent shale, and 36-151 μg/l from fresh spent shale. Among the studied PAHs the low-molecular weight compounds phenanthrene, naphthalene, acenaphthylene, and anthracene predominated. Among the high-molecular weight PAHs benzo[a]anthracene and pyrene leached in the highest concentrations. A spent shale deposit is a source of PAHs that could infiltrate into the surrounding environment for a long period of time. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Three-dimensional rotation electron diffraction: software RED for automated data collection and data processing

    PubMed Central

    Wan, Wei; Sun, Junliang; Su, Jie; Hovmöller, Sven; Zou, Xiaodong

    2013-01-01

    Implementation of a computer program package for automated collection and processing of rotation electron diffraction (RED) data is described. The software package contains two computer programs: RED data collection and RED data processing. The RED data collection program controls the transmission electron microscope and the camera. Electron beam tilts at a fine step (0.05–0.20°) are combined with goniometer tilts at a coarse step (2.0–3.0°) around a common tilt axis, which allows a fine relative tilt to be achieved between the electron beam and the crystal in a large tilt range. An electron diffraction (ED) frame is collected at each combination of beam tilt and goniometer tilt. The RED data processing program processes three-dimensional ED data generated by the RED data collection program or by other approaches. It includes shift correction of the ED frames, peak hunting for diffraction spots in individual ED frames and identification of these diffraction spots as reflections in three dimensions. Unit-cell parameters are determined from the positions of reflections in three-dimensional reciprocal space. All reflections are indexed, and finally a list with hkl indices and intensities is output. The data processing program also includes a visualizer to view and analyse three-dimensional reciprocal lattices reconstructed from the ED frames. Details of the implementation are described. Data collection and data processing with the software RED are demonstrated using a calcined zeolite sample, silicalite-1. The structure of the calcined silicalite-1, with 72 unique atoms, could be solved from the RED data by routine direct methods. PMID:24282334

  7. Three-dimensional rotation electron diffraction: software RED for automated data collection and data processing.

    PubMed

    Wan, Wei; Sun, Junliang; Su, Jie; Hovmöller, Sven; Zou, Xiaodong

    2013-12-01

    Implementation of a computer program package for automated collection and processing of rotation electron diffraction (RED) data is described. The software package contains two computer programs: RED data collection and RED data processing. The RED data collection program controls the transmission electron microscope and the camera. Electron beam tilts at a fine step (0.05-0.20°) are combined with goniometer tilts at a coarse step (2.0-3.0°) around a common tilt axis, which allows a fine relative tilt to be achieved between the electron beam and the crystal in a large tilt range. An electron diffraction (ED) frame is collected at each combination of beam tilt and goniometer tilt. The RED data processing program processes three-dimensional ED data generated by the RED data collection program or by other approaches. It includes shift correction of the ED frames, peak hunting for diffraction spots in individual ED frames and identification of these diffraction spots as reflections in three dimensions. Unit-cell parameters are determined from the positions of reflections in three-dimensional reciprocal space. All reflections are indexed, and finally a list with hkl indices and intensities is output. The data processing program also includes a visualizer to view and analyse three-dimensional reciprocal lattices reconstructed from the ED frames. Details of the implementation are described. Data collection and data processing with the software RED are demonstrated using a calcined zeolite sample, silicalite-1. The structure of the calcined silicalite-1, with 72 unique atoms, could be solved from the RED data by routine direct methods.

  8. General introduction for the “National Field Manual for the Collection of Water-Quality Data”

    USGS Publications Warehouse

    ,

    2018-02-28

    BackgroundAs part of its mission, the U.S. Geological Survey (USGS) collects data to assess the quality of our Nation’s water resources. A high degree of reliability and standardization of these data are paramount to fulfilling this mission. Documentation of nationally accepted methods used by USGS personnel serves to maintain consistency and technical quality in data-collection activities. “The National Field Manual for the Collection of Water-Quality Data” (NFM) provides documented guidelines and protocols for USGS field personnel who collect water-quality data. The NFM provides detailed, comprehensive, and citable procedures for monitoring the quality of surface water and groundwater. Topics in the NFM include (1) methods and protocols for sampling water resources, (2) methods for processing samples for analysis of water quality, (3) methods for measuring field parameters, and (4) specialized procedures, such as sampling water for low levels of mercury and organic wastewater chemicals, measuring biological indicators, and sampling bottom sediment for chemistry. Personnel who collect water-quality data for national USGS programs and projects, including projects supported by USGS cooperative programs, are mandated to use protocols provided in the NFM per USGS Office of Water Quality Technical Memorandum 2002.13. Formal training, for example, as provided in the USGS class, “Field Water-Quality Methods for Groundwater and Surface Water,” and field apprenticeships supplement the guidance provided in the NFM and ensure that the data collected are high quality, accurate, and scientifically defensible.

  9. Illustrated field guide for assessing external and internal anomalies in fish

    USGS Publications Warehouse

    Smith, Stephen B.; Donahue, Anne P.; Lipkin, Robin J.; Blazer, Vicki; Schmitt, Christopher J.; Goede, Ronald W.

    2002-01-01

    Procedures are described for processing fish for examination of external and internal anomalies and pathologies indicative of exposure to environmental contaminants and other peturbations. For the procedures described here, fish are captured (preferably by electrofishing) and held alive until processing (generally < 1 h). Fish are weighed, measured, and necropsied, and a scale sample is obtained from for age determination. Information is given for the collection and preservation of tissue samples for histopathological analysis. Photographs of most abnormalities are included along with normal conditions for easier identification of external (oral, head, eye, gill, opercula, and fin) and internal (liver, spleen, gonad, and kidney) anomalies. The report also includes recommendations for record keeping, sample labeling, and shipping records, equipment, supplies,and samples. A list of suggested equipment and supplies for field processing is included as are instructions for cleaning equipment.

  10. Automated collection and processing of environmental samples

    DOEpatents

    Troyer, Gary L.; McNeece, Susan G.; Brayton, Darryl D.; Panesar, Amardip K.

    1997-01-01

    For monitoring an environmental parameter such as the level of nuclear radiation, at distributed sites, bar coded sample collectors are deployed and their codes are read using a portable data entry unit that also records the time of deployment. The time and collector identity are cross referenced in memory in the portable unit. Similarly, when later recovering the collector for testing, the code is again read and the time of collection is stored as indexed to the sample collector, or to a further bar code, for example as provided on a container for the sample. The identity of the operator can also be encoded and stored. After deploying and/or recovering the sample collectors, the data is transmitted to a base processor. The samples are tested, preferably using a test unit coupled to the base processor, and again the time is recorded. The base processor computes the level of radiation at the site during exposure of the sample collector, using the detected radiation level of the sample, the delay between recovery and testing, the duration of exposure and the half life of the isotopes collected. In one embodiment, an identity code and a site code are optically read by an image grabber coupled to the portable data entry unit.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marutzky, Sam; Farnham, Irene

    The purpose of the Nevada National Security Site (NNSS) Integrated Sampling Plan (referred to herein as the Plan) is to provide a comprehensive, integrated approach for collecting and analyzing groundwater samples to meet the needs and objectives of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) Underground Test Area (UGTA) Activity. Implementation of this Plan will provide high-quality data required by the UGTA Activity for ensuring public protection in an efficient and cost-effective manner. The Plan is designed to ensure compliance with the UGTA Quality Assurance Plan (QAP). The Plan’s scope comprises sample collectionmore » and analysis requirements relevant to assessing the extent of groundwater contamination from underground nuclear testing. This Plan identifies locations to be sampled by corrective action unit (CAU) and location type, sampling frequencies, sample collection methodologies, and the constituents to be analyzed. In addition, the Plan defines data collection criteria such as well-purging requirements, detection levels, and accuracy requirements; identifies reporting and data management requirements; and provides a process to ensure coordination between NNSS groundwater sampling programs for sampling of interest to UGTA. This Plan does not address compliance with requirements for wells that supply the NNSS public water system or wells involved in a permitted activity.« less

  12. Environmental research program for slagging fixed-bed coal gasification. Status report, November 1981

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilzbach, K. E.; Stetter, J. R.; Reilly, Jr., C. A.

    1982-02-01

    A collaborative environmental research program to provide information needed to assess the health and environmental effects associated with large-scale coal gasification technology is being conducted by Argonne National Laboratory (ANL) and the Grand Forks Energy Technology Center (GFETC). The objectives are to: investigate the toxicology and chemical composition of coal gasification by-products as a function of process variables and coal feed; compare the characteristics of isokinetic side-stream samples with those of process stream samples; identify the types of compounds responsible for toxicity; evaluate the chemical and toxicological effectiveness of various wastewater treatment operations; refine methodology for the collection and measurementmore » of organic vapors and particulates in workplace air; and obtain preliminary data on workplace air quality. So far the toxicities of a set of process stream samples (tar, oil, and gas liquor) and side-stream condensates from the GFETC gasifier have been measured in a battery of cellular screening tests for mutagenicity and cytotoxicity. Preliminary data on the effects of acute and chronic exposures of laboratory animals to process tar have been obtained. The process tar has been chemically fractionated and the distribution of mutagenicity and compound types among the fractions has been determined. Organic vapors and particulates collected at various times and locations in the gasifier building have been characterized.« less

  13. Coffee husk composting: An investigation of the process using molecular and non-molecular tools

    PubMed Central

    Shemekite, Fekadu; Gómez-Brandón, María; Franke-Whittle, Ingrid H.; Praehauser, Barbara; Insam, Heribert; Assefa, Fassil

    2014-01-01

    Various parameters were measured during a 90-day composting process of coffee husk with cow dung (Pile 1), with fruit/vegetable wastes (Pile 2) and coffee husk alone (Pile 3). Samples were collected on days 0, 32 and 90 for chemical and microbiological analyses. C/N ratios of Piles 1 and 2 decreased significantly over the 90 days. The highest bacterial counts at the start of the process and highest actinobacterial counts at the end of the process (Piles 1 and 2) indicated microbial succession with concomitant production of compost relevant enzymes. Denaturing gradient gel electrophoresis of rDNA and COMPOCHIP microarray analysis indicated distinctive community shifts during the composting process, with day 0 samples clustering separately from the 32 and 90-day samples. This study, using a multi-parameter approach, has revealed differences in quality and species diversity of the three composts. PMID:24369846

  14. Quality of wet deposition in the Grand Calumet River watershed, northwestern Indiana, April 29, 1997-April 28, 1998

    USGS Publications Warehouse

    Willoughby, Timothy C.

    2000-01-01

    The Grand Calumet River, in northwestern Indiana, drains a heavily industrialized area along the southern shore of Lake Michigan. Steel production and petroleum refining are two of the area?s predominant industries. High-temperature processes, such as fossilfuel combustion and steel production, release contaminants to the atmosphere that may result in wet deposition being a major contributor to major-ion and trace-metal loadings in northwestern Indiana and Lake Michigan. A wet-deposition collection site was established at the Gary (Indiana) Regional Airport to monitor the quantity and chemical quality of wet deposition. During a first phase of sampling, 48 wet-deposition samples were collected weekly between June 30, 1992, and August 31, 1993. During a second phase of sampling, 40 wet-deposition samples were collected between October 17, 1995, and November 12, 1996. Forty-two wet-deposition samples were collected during a third phase of sampling, which began April 29, 1997, and was completed April 28, 1998. Wetdeposition samples were analyzed for pH, specific conductance, and selected major ions and trace metals. This report describes the quantity and quality of wet-deposition samples collected during the third sampling phase and compares these findings to the results of the first and second sampling phases. All of the samples collected during the third phase of sampling were of sufficient volumes for at least some of the analyses to be performed. Constituent concentrations from the third sampling phase were not significantly different (at the 5-percent significance level) from those for the second sampling phase. Significant increases, however, were observed in the concentrations of potassium, iron, lead, and zinc when compared to the concentrations observed in the first sampling phase. Weekly loadings were estimated for each constituent measured during the third sampling phase. If constituent concentrations were reported less than the method reporting limit, a range for the weekly loading was computed. The estimated annual loadings of chloride, silica, bromide, copper, and zinc during the third sampling phase were greater than those estimated for the first two sampling phases. The only estimated annual loading in the third sampling phase that was less than the estimated annual loadings observed during the first two sampling phases was sulfate. The estimated annual loadings of calcium, magnesium, nitrate, potassium, barium, lead, iron, and manganese observed during the third sampling phase were greater than the loadings observed during the first sampling phase but less than those observed during the second sampling phase. No significant differences were observed between the quantity of wet deposition collected during the three sampling phases.

  15. Field measurements of biogenic volatile organic compounds in the atmosphere using solid-phase microextraction Arrow

    NASA Astrophysics Data System (ADS)

    Feijó Barreira, Luís Miguel; Duporté, Geoffroy; Rönkkö, Tuukka; Parshintsev, Jevgeni; Hartonen, Kari; Hyrsky, Lydia; Heikkinen, Enna; Jussila, Matti; Kulmala, Markku; Riekkola, Marja-Liisa

    2018-02-01

    Biogenic volatile organic compounds (BVOCs) emitted by terrestrial vegetation participate in a diversity of natural processes. These compounds impact both short-range processes, such as on plant protection and communication, and long-range processes, for example by participating in aerosol particle formation and growth. The biodiversity of plant species around the Earth, the vast assortment of emitted BVOCs, and their trace atmospheric concentrations contribute to the substantial remaining uncertainties about the effects of these compounds on atmospheric chemistry and physics, and call for the development of novel collection devices that can offer portability with improved selectivity and capacity. In this study, a novel solid-phase microextraction (SPME) Arrow sampling system was used for the static and dynamic collection of BVOCs from a boreal forest, and samples were subsequently analyzed on site by gas chromatography-mass spectrometry (GC-MS). This system offers higher sampling capacity and improved robustness when compared to traditional equilibrium-based SPME techniques, such as SPME fibers. Field measurements were performed in summer 2017 at the Station for Measuring Ecosystem-Atmosphere Relations (SMEAR II) in Hyytiälä, Finland. Complementary laboratory tests were also performed to compare the SPME-based techniques under controlled experimental conditions and to evaluate the effect of temperature and relative humidity on their extraction performance. The most abundant monoterpenes and aldehydes were successfully collected. A significant improvement on sampling capacity was observed with the new SPME Arrow system over SPME fibers, with collected amounts being approximately 2 × higher for monoterpenes and 7-8 × higher for aldehydes. BVOC species exhibited different affinities for the type of sorbent materials used (polydimethylsiloxane (PDMS)-carbon wide range (WR) vs. PDMS-divinylbenzene (DVB)). Higher extraction efficiencies were obtained with dynamic collection prior to equilibrium regime, but this benefit during the field measurements was small, probably due to the natural agitation provided by the wind. An increase in temperature and relative humidity caused a decrease in the amounts of analytes extracted under controlled experimental conditions, even though the effect was more significant for PDMS-carbon WR than for PDMS-DVB. Overall, results demonstrated the benefits and challenges of using SPME Arrow for the sampling of BVOCs in the atmosphere.

  16. Designing and implementing sample and data collection for an international genetics study: the Type 1 Diabetes Genetics Consortium (T1DGC).

    PubMed

    Hilner, Joan E; Perdue, Letitia H; Sides, Elizabeth G; Pierce, June J; Wägner, Ana M; Aldrich, Alan; Loth, Amanda; Albret, Lotte; Wagenknecht, Lynne E; Nierras, Concepcion; Akolkar, Beena

    2010-01-01

    The Type 1 Diabetes Genetics Consortium (T1DGC) is an international project whose primary aims are to: (a) discover genes that modify type 1 diabetes risk; and (b) expand upon the existing genetic resources for type 1 diabetes research. The initial goal was to collect 2500 affected sibling pair (ASP) families worldwide. T1DGC was organized into four regional networks (Asia-Pacific, Europe, North America, and the United Kingdom) and a Coordinating Center. A Steering Committee, with representatives from each network, the Coordinating Center, and the funding organizations, was responsible for T1DGC operations. The Coordinating Center, with regional network representatives, developed study documents and data systems. Each network established laboratories for: DNA extraction and cell line production; human leukocyte antigen genotyping; and autoantibody measurement. Samples were tracked from the point of collection, processed at network laboratories and stored for deposit at National Institute for Diabetes and Digestive and Kidney Diseases (NIDDK) Central Repositories. Phenotypic data were collected and entered into the study database maintained by the Coordinating Center. T1DGC achieved its original ASP recruitment goal. In response to research design changes, the T1DGC infrastructure also recruited trios, cases, and controls. Results of genetic analyses have identified many novel regions that affect susceptibility to type 1 diabetes. T1DGC created a resource of data and samples that is accessible to the research community. Participation in T1DGC was declined by some countries due to study requirements for the processing of samples at network laboratories and/or final deposition of samples in NIDDK Central Repositories. Re-contact of participants was not included in informed consent templates, preventing collection of additional samples for functional studies. T1DGC implemented a distributed, regional network structure to reach ASP recruitment targets. The infrastructure proved robust and flexible enough to accommodate additional recruitment. T1DGC has established significant resources that provide a basis for future discovery in the study of type 1 diabetes genetics.

  17. Evaluation of GasmetTM DX-4015 Series Fourier Transform Infrared Gas Analyzer

    DTIC Science & Technology

    2009-06-01

    penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number PLEASE DO NOT RETURN YOUR...Series FTIR Gas Analyzer Instrument test conditions simulated current ALS Increment 0 conditions. Briefly, unknown samples are collected in a "hot...a 1M cell. Emission radiation can be collected following a reflection or transmission process. Only one system is being considered and that system

  18. Analysis of water from the Space Shuttle and Mir Space Station by ion chromatography and capillary electrophoresis

    NASA Technical Reports Server (NTRS)

    Orta, D.; Mudgett, P. D.; Ding, L.; Drybread, M.; Schultz, J. R.; Sauer, R. L.

    1998-01-01

    Drinking water and condensate samples collected from the US Space Shuttle and the Russian Mir Space Station are analyzed routinely at the NASA-Johnson Space Center as part of an ongoing effort to verify water quality and monitor the environment of the spacecraft. Water quality monitoring is particularly important for the Mir water supply because approximately half of the water consumed is recovered from humidity condensate. Drinking water on Shuttle is derived from the fuel cells. Because there is little equipment on board the spacecraft for monitoring the water quality, samples collected by the crew are transported to Earth on Shuttle or Soyuz vehicles, and analyzed exhaustively. As part of the test battery, anions and cations are measured by ion chromatography, and carboxylates and amines by capillary electrophoresis. Analytical data from Shuttle water samples collected before and after several missions, and Mir condensate and potable recovered water samples representing several recent missions are presented and discussed. Results show that Shuttle water is of distilled quality, and Mir recovered water contains various levels of minerals imparted during the recovery processes as designed. Organic ions are rarely detected in potable water samples, but were present in humidity condensate samples.

  19. Carbon-13 Isotopic Abundance and Concentration of Atmospheric Methane for Background Air in the Southern and Northern Hemispheres from 1978 to 1989 (NDP-049)

    DOE Data Explorer

    Stevens, C. M. [Chemical Technology Division, Argonne National Laboratory, Argonne, Illinois (USA)

    2012-01-01

    This data package presents atmospheric CH4 concentration and 13C isotopic abundance data derived from air samples collected over the period 1978-1989 at globally distributed clean-air sites. The data set comprises 201 records, 166 from the Northern Hemisphere and 35 from the Southern Hemisphere. The air samples were collected mostly in rural or marine locations remote from large sources of CH4 and are considered representative of tropospheric background conditions. The air samples were processed by isolation of CH4 from air and conversion to CO2 for isotopic analysis by isotope ratio mass spectrometry. These data represent one of the earliest records of 13C isotopic yy!measurements for atmospheric methane and have been used to refine estimates of CH4 emissions, calculate annual growth rates of emissions from changing sources, and provide evidence for changes in the rate of atmospheric removal of CH4. The data records consist of sample collection date; number of samples combined for analysis; sampling location; analysis date; CH4 concentration; 13C isotopic abundance; and flag codes to indicate outliers, repeated analyses, and other information.

  20. Integration of Apollo Lunar Sample Data into Google Moon

    NASA Technical Reports Server (NTRS)

    Dawson, Melissa D.; Todd, Nancy S.; Lofgren, Gary

    2010-01-01

    The Google Moon Apollo Lunar Sample Data Integration project is a continuation of the Apollo 15 Google Moon Add-On project, which provides a scientific and educational tool for the study of the Moon and its geologic features. The main goal of this project is to provide a user-friendly interface for an interactive and educational outreach and learning tool for the Apollo missions. Specifically, this project?s focus is the dissemination of information about the lunar samples collected during the Apollo missions by providing any additional information needed to enhance the Apollo mission data on Google Moon. Apollo missions 15 and 16 were chosen to be completed first due to the availability of digitized lunar sample photographs and the amount of media associated with these missions. The user will be able to learn about the lunar samples collected in these Apollo missions, as well as see videos, pictures, and 360 degree panoramas of the lunar surface depicting the lunar samples in their natural state, following collection and during processing at NASA. Once completed, these interactive data layers will be submitted for inclusion into the Apollo 15 and 16 missions on Google Moon.

  1. Blood venous sample collection: Recommendations overview and a checklist to improve quality.

    PubMed

    Giavarina, Davide; Lippi, Giuseppe

    2017-07-01

    The extra-analytical phases of the total testing process have substantial impact on managed care, as well as an inherent high risk of vulnerability to errors which is often greater than that of the analytical phase. The collection of biological samples is a crucial preanalytical activity. Problems or errors occurring shortly before, or soon after, this preanalytical step may impair sample quality and characteristics, or else modify the final results of testing. The standardization of fasting requirements, rest, patient position and psychological state of the patient are therefore crucial for mitigating the impact of preanalytical variability. Moreover, the quality of materials used for collecting specimens, along with their compatibility, can guarantee sample quality and persistence of chemical and physical characteristics of the analytes over time, so safeguarding the reliability of testing. Appropriate techniques and sampling procedures are effective to prevent problems such as hemolysis, undue clotting in the blood tube, draw of insufficient sample volume and modification of analyte concentration. An accurate identification of both patient and blood samples is a key priority as for other healthcare activities. Good laboratory practice and appropriate training of operators, by specifically targeting collection of biological samples, blood in particular, may greatly improve this issue, thus lowering the risk of errors and their adverse clinical consequences. The implementation of a simple and rapid check-list, including verification of blood collection devices, patient preparation and sampling techniques, was found to be effective for enhancing sample quality and reducing some preanalytical errors associated with these procedures. The use of this tool, along with implementation of objective and standardized systems for detecting non-conformities related to unsuitable samples, can be helpful for standardizing preanalytical activities and improving the quality of laboratory diagnostics, ultimately helping to reaffirm a "preanalytical" culture founded on knowledge and real risk perception. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. Hand held data collection and monitoring system for nuclear facilities

    DOEpatents

    Brayton, D.D.; Scharold, P.G.; Thornton, M.W.; Marquez, D.L.

    1999-01-26

    Apparatus and method is disclosed for a data collection and monitoring system that utilizes a pen based hand held computer unit which has contained therein interaction software that allows the user to review maintenance procedures, collect data, compare data with historical trends and safety limits, and input new information at various collection sites. The system has a means to allow automatic transfer of the collected data to a main computer data base for further review, reporting, and distribution purposes and uploading updated collection and maintenance procedures. The hand held computer has a running to-do list so sample collection and other general tasks, such as housekeeping are automatically scheduled for timely completion. A done list helps users to keep track of all completed tasks. The built-in check list assures that work process will meet the applicable processes and procedures. Users can hand write comments or drawings with an electronic pen that allows the users to directly interface information on the screen. 15 figs.

  3. Hand held data collection and monitoring system for nuclear facilities

    DOEpatents

    Brayton, Darryl D.; Scharold, Paul G.; Thornton, Michael W.; Marquez, Diana L.

    1999-01-01

    Apparatus and method is disclosed for a data collection and monitoring system that utilizes a pen based hand held computer unit which has contained therein interaction software that allows the user to review maintenance procedures, collect data, compare data with historical trends and safety limits, and input new information at various collection sites. The system has a means to allow automatic transfer of the collected data to a main computer data base for further review, reporting, and distribution purposes and uploading updated collection and maintenance procedures. The hand held computer has a running to-do list so sample collection and other general tasks, such as housekeeping are automatically scheduled for timely completion. A done list helps users to keep track of all completed tasks. The built-in check list assures that work process will meet the applicable processes and procedures. Users can hand write comments or drawings with an electronic pen that allows the users to directly interface information on the screen.

  4. Rain sampling device

    DOEpatents

    Nelson, D.A.; Tomich, S.D.; Glover, D.W.; Allen, E.V.; Hales, J.M.; Dana, M.T.

    1991-05-14

    The present invention constitutes a rain sampling device adapted for independent operation at locations remote from the user which allows rainfall to be sampled in accordance with any schedule desired by the user. The rain sampling device includes a mechanism for directing wet precipitation into a chamber, a chamber for temporarily holding the precipitation during the process of collection, a valve mechanism for controllably releasing samples of the precipitation from the chamber, a means for distributing the samples released from the holding chamber into vessels adapted for permanently retaining these samples, and an electrical mechanism for regulating the operation of the device. 11 figures.

  5. Rain sampling device

    DOEpatents

    Nelson, Danny A.; Tomich, Stanley D.; Glover, Donald W.; Allen, Errol V.; Hales, Jeremy M.; Dana, Marshall T.

    1991-01-01

    The present invention constitutes a rain sampling device adapted for independent operation at locations remote from the user which allows rainfall to be sampled in accordance with any schedule desired by the user. The rain sampling device includes a mechanism for directing wet precipitation into a chamber, a chamber for temporarily holding the precipitation during the process of collection, a valve mechanism for controllably releasing samples of said precipitation from said chamber, a means for distributing the samples released from the holding chamber into vessels adapted for permanently retaining these samples, and an electrical mechanism for regulating the operation of the device.

  6. 75 FR 16424 - Proposed Information Collection; Comment Request; Census Coverage Measurement Final Housing Unit...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-01

    ... unit is a block cluster, which consists of one or more geographically contiguous census blocks. As in... a number of distinct processes, ranging from forming block clusters, selecting the block clusters... sample of block clusters, while the E Sample is the census of housing units and enumerations in the same...

  7. Subpopulations of bovine T lymphocytes collected during foot-and-mouth disease virus infection are affected by freezing, but are subsequently stable in frozen samples

    USDA-ARS?s Scientific Manuscript database

    Immunophenotyping of peripheral-blood lymphocytes by flow cytometry is an important tool for infectious disease research. In many live-animal experiments and other longitudinal studies, the processing, prompt staining, and analysis of fresh samples is a logistical challenge and daily variation can c...

  8. Basic tree-ring sample preparation techniques for aging aspen

    Treesearch

    Lance A. Asherin; Stephen A. Mata

    2001-01-01

    Aspen is notoriously difficult to age because of its light-colored wood and faint annual growth rings. Careful preparation and processing of aspen ring samples can overcome these problems, yield accurate age and growth estimates, and concisely date disturbance events present in the tree-ring record. Proper collection of aspen wood is essential in obtaining usable ring...

  9. The Emotions of Socialization-Related Learning: Understanding Workplace Adaptation as a Learning Process.

    ERIC Educational Resources Information Center

    Reio, Thomas G., Jr.

    The influence of selected discrete emotions on socialization-related learning and perception of workplace adaptation was examined in an exploratory study. Data were collected from 233 service workers in 4 small and medium-sized companies in metropolitan Washington, D.C. The sample members' average age was 32.5 years, and the sample's racial makeup…

  10. Optical analyzer

    DOEpatents

    Hansen, Anthony D.

    1989-02-07

    An optical analyzer (10) wherein a sample (19) of particulate matter, and particularly of organic matter, which has been collected on a quartz fiber filter (20) is placed in a combustion tube (11), and light from a light source (14) is passed through the sample (19). The temperature of the sample (19) is raised at a controlled rate and in a controlled atmosphere. The magnitude of the transmission of light through the sample (19) is detected (18) as the temperature is raised. A data processor (23), differentiator (28) and a two pen recorder (24) provide a chart of the optical transmission versus temperature and the rate of change of optical transmission versus temperature signatures (T and D) of the sample (19). These signatures provide information as to physical and chemical processes and a variety of quantitative and qualitative information about the sample (19). Additional information is obtained by repeating the run in different atmospheres and/or different rates of heating with other samples of the same particulate material collected on other filters.

  11. The Apollo Lunar Sample Image Collection: Digital Archiving and Online Access

    NASA Technical Reports Server (NTRS)

    Todd, Nancy S.; Lofgren, Gary E.; Stefanov, William L.; Garcia, Patricia A.

    2014-01-01

    The primary goal of the Apollo Program was to land human beings on the Moon and bring them safely back to Earth. This goal was achieved during six missions - Apollo 11, 12, 14, 15, 16, and 17 - that took place between 1969 and 1972. Among the many noteworthy engineering and scientific accomplishments of these missions, perhaps the most important in terms of scientific impact was the return of 382 kg (842 lb.) of lunar rocks, core samples, pebbles, sand, and dust from the lunar surface to Earth. Returned samples were curated at JSC (then known as the Manned Spacecraft Center) and, as part of the original processing, high-quality photographs were taken of each sample. The top, bottom, and sides of each rock sample were photographed, along with 16 stereo image pairs taken at 45-degree intervals. Photographs were also taken whenever a sample was subdivided and when thin sections were made. This collection of lunar sample images consists of roughly 36,000 photographs; all six Apollo missions are represented.

  12. Optical analyzer

    DOEpatents

    Hansen, Anthony D.

    1989-01-01

    An optical analyzer (10) wherein a sample (19) of particulate matter, and particularly of organic matter, which has been collected on a quartz fiber filter (20) is placed in a combustion tube (11), and light from a light source (14) is passed through the sample (19). The temperature of the sample (19) is raised at a controlled rate and in a controlled atmosphere. The magnitude of the transmission of light through the sample (19) is detected (18) as the temperature is raised. A data processor (23), differentiator (28) and a two pen recorder (24) provide a chart of the optical transmission versus temperature and the rate of change of optical transmission versus temperature signatures (T and D) of the sample (19). These signatures provide information as to physical and chemical processes and a variety of quantitative and qualitative information about the sample (19). Additional information is obtained by repeating the run in different atmospheres and/or different rates of heating with other samples of the same particulate material collected on other filters.

  13. A Data-Centric Strategy for Modern Biobanking.

    PubMed

    Quinlan, Philip R; Gardner, Stephen; Groves, Martin; Emes, Richard; Garibaldi, Jonathan

    2015-01-01

    Biobanking has been in existence for many decades and over that time has developed significantly. Biobanking originated from a need to collect, store and make available biological samples for a range of research purposes. It has changed as the understanding of biological processes has increased and new sample handling techniques have been developed to ensure samples were fit-for-purpose.As a result of these developments, modern biobanking is now facing two substantial new challenges. Firstly, new research methods such as next generation sequencing can generate datasets that are at an infinitely greater scale and resolution than previous methods. Secondly, as the understanding of diseases increases researchers require a far richer data set about the donors from which the sample originate.To retain a sample-centric strategy in a research environment that is increasingly dictated by data will place a biobank at a significant disadvantage and even result in the samples collected going unused. As a result biobanking is required to change strategic focus from a sample dominated perspective to a data-centric strategy.

  14. Clinical and technical considerations in the analysis of gingival crevicular fluid.

    PubMed

    Wassall, Rebecca R; Preshaw, Philip M

    2016-02-01

    Despite the technical challenges involved when collecting, processing and analyzing gingival crevicular fluid samples, research using gingival crevicular fluid has, and will continue to play, a fundamental role in expanding our understanding of periodontal pathogenesis and healing outcomes following treatment. A review of the literature, however, clearly demonstrates that there is considerable variation in the methods used for collection, processing and analysis of gingival crevicular fluid samples by different research groups around the world. Inconsistent or inadequate reporting impairs interpretation of results, prevents accurate comparison of data between studies and potentially limits the conclusions that can be made from a larger body of evidence. The precise methods used for collection and analysis of gingival crevicular fluid (including calibration studies required before definitive clinical studies) should be reported in detail, either in the methods section of published papers or as an online supplementary file, so that other researchers may reproduce the methodology. Only with clear and transparent reporting will the full impact of future gingival crevicular fluid research be realized. This paper discusses the complexities of gingival crevicular fluid collection and analysis and provides guidance to researchers working in this field. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Optical selection and collection of DNA fragments

    DOEpatents

    Roslaniec, Mary C.; Martin, John C.; Jett, James H.; Cram, L. Scott

    1998-01-01

    Optical selection and collection of DNA fragments. The present invention includes the optical selection and collection of large (>.mu.g) quantities of clonable, chromosome-specific DNA from a sample of chromosomes. Chromosome selection is based on selective, irreversible photoinactivation of unwanted chromosomal DNA. Although more general procedures may be envisioned, the invention is demonstrated by processing chromosomes in a conventional flow cytometry apparatus, but where no droplets are generated. All chromosomes in the sample are first stained with at least one fluorescent analytic dye and bonded to a photochemically active species which can render chromosomal DNA unclonable if activated. After passing through analyzing light beam(s), unwanted chromosomes are irradiated using light which is absorbed by the photochemically active species, thereby causing photoinactivation. As desired chromosomes pass this photoinactivation point, the inactivating light source is deflected by an optical modulator; hence, desired chromosomes are not photoinactivated and remain clonable. The selection and photoinactivation processes take place on a microsecond timescale. By eliminating droplet formation, chromosome selection rates 50 times greater than those possible with conventional chromosome sorters may be obtained. Thus, usable quantities of clonable DNA from any source thereof may be collected.

  16. Circulating tumoral cells lack circadian-rhythm in hospitalized metastasic breast cancer patients.

    PubMed

    García-Sáenz, José Angel; Martín, Miguel; Maestro, Marisa; Vidaurreta, Marta; Veganzones, Silvia; Villalobos, Laura; Rodríguez-Lajusticia, Laura; Rafael, Sara; Sanz-Casla, María Teresa; Casado, Antonio; Sastre, Javier; Arroyo, Manuel; Díaz-Rubio, Eduardo

    2006-11-01

    The relationship between breast cancer and circadian rhythm variation has been extensively studied. Increased breast tumorigenesis has been reported in melatonin-suppressed experimental models and in observational studies. Circulating Tumor Cells (CTC) circadian- rhythm may optimize the timing of therapies. This is a prospective experimental study to ascertain the day-time and night-time CTC levels in hospitalized metastasic breast cancer (MBC) patients. CTC are isolated and enumerated from a 08:00 AM and 08:00 PM blood collections. 23 MBC and 23 healthy volunteers entered the study. 69 samples were collected (23 samples at 08:00 AM and 23 samples at 08:00 PM from MBC; 23 samples from healthy volunteers). Results from two patients were rejected due to sample processing errors. No CTC were isolated from healthy-volunteers. No-differences between daytime and night-time CTC were observed. Therefore, we could not ascertain CTC circadian-rhythm in hospitalized metastasic breast cancer patients.

  17. Evaluation of Sampling Methods for Bacillus Spore ...

    EPA Pesticide Factsheets

    Journal Article Following a wide area release of biological materials, mapping the extent of contamination is essential for orderly response and decontamination operations. HVAC filters process large volumes of air and therefore collect highly representative particulate samples in buildings. HVAC filter extraction may have great utility in rapidly estimating the extent of building contamination following a large-scale incident. However, until now, no studies have been conducted comparing the two most appropriate sampling approaches for HVAC filter materials: direct extraction and vacuum-based sampling.

  18. Science Teachers' Information Processing Behaviours in Nepal: A Reflective Comparative Study

    ERIC Educational Resources Information Center

    Acharya, Kamal Prasad

    2017-01-01

    This study examines the investigation of the information processing behaviours of secondary level science teachers. It is based on the data collected from 50 secondary level school science teachers working in Kathmandy valley. The simple random sampling and the Cognitive Style Inventory have been used respectively as the technique and tool to…

  19. Literature Review on Processing and Analytical Methods for ...

    EPA Pesticide Factsheets

    Report The purpose of this report was to survey the open literature to determine the current state of the science regarding the processing and analytical methods currently available for recovery of F. tularensis from water and soil matrices, and to determine what gaps remain in the collective knowledge concerning F. tularensis identification from environmental samples.

  20. Characterization of plastic blends made from mixed plastics waste of different sources.

    PubMed

    Turku, Irina; Kärki, Timo; Rinne, Kimmo; Puurtinen, Ari

    2017-02-01

    This paper studies the recyclability of construction and household plastic waste collected from local landfills. Samples were processed from mixed plastic waste by injection moulding. In addition, blends of pure plastics, polypropylene and polyethylene were processed as a reference set. Reference samples with known plastic ratio were used as the calibration set for quantitative analysis of plastic fractions in recycled blends. The samples were tested for the tensile properties; scanning electron microscope-energy-dispersive X-ray spectroscopy was used for elemental analysis of the blend surfaces and Fourier transform infrared (FTIR) analysis was used for the quantification of plastics contents.

  1. Collection and processing of plant, animal and soil samples from Bikini, Enewetak and Rongelap Atolls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stuart, M.L.

    1995-09-01

    The United States used the Marshall Islands for its nuclear weapons program testing site from 1946 to 1958. The BRAVO test was detonated at Bikini Atoll on March 1, 1954. Due to shifting wind conditions at the time of the nuclear detonation, many of the surrounding Atolls became contaminated with fallout (radionuclides carried by the wind currents). Lawrence Livermore National Laboratory`s (LLNL) Marshall Islands Project has been responsible for the collecting, processing, and analyzing of food crops, vegetation, soil, water, animals, and marine species to characterize the radionuclides in the environment, and to estimate dose at atolls that may havemore » been contaminated. Tropical agriculture experiments reducing the uptake of {sup 137}Cs have been conducted on Bikini Atoll. The Marshall Islands field team and laboratory processing team play an important role in the overall scheme of the Marshall Islands Dose Assessment and Radioecology Project. This report gives a general description of the Marshall Islands field sampling and laboratory processing procedures currently used by our staff.« less

  2. Permeation-solid adsorbent sampling and GC analysis of formaldehyde.

    PubMed

    Muntuta-Kinyanta, C; Hardy, J K

    1991-12-01

    A passive method with membrane permeation sampling for the determination of time-weighted-average (TWA) concentration of formaldehyde in air is described. The sampling device was constructed by affixing an unbacked dimethyl silicone membrane to the base of a glass tube and by sealing the top with a rubber stopper. Formaldehyde permeates the membrane and reacts with 2-(hydroxymethyl)piperidine (2-HMP) coated on the surface of XAD-2. Sampling times from 15 min to 8 hr have been used. The formaldehyde-oxazolidine produced is thermally desorbed and determined by a packed column gas chromatograph equipped with a flame ionization detector (FID). The response of the monitor is directly proportional to the external concentration of formaldehyde over the concentration range 0.050-100 ppm. The permeation constant (the slope of the permeation curve) of the membrane is 0.333 mug ppm(-1). hr, and the detection limit of the method is 0.03 ppm for an 8-hr sampling period. Relative humidity (RH) (35-94%), temperature (0-82 degrees ) and storage period (0-25 days) do not affect the permeation process for sample collection. Moreover, potential chemical interferences, 10 ppm acetone or acrolein, respectively, have no detectable effect on the process. The method gives TWA concentration directly from the measurements, and the equipment is economical and convenient for personal or multi-location sample collections.

  3. Measurements of airborne methylene diphenyl diisocyanate (MDI) concentration in the U.S. workplace.

    PubMed

    Booth, Karroll; Cummings, Barbara; Karoly, William J; Mullins, Sharon; Robert, William P; Spence, Mark; Lichtenberg, Fran W; Banta, J

    2009-04-01

    This article summarizes a large body of industry air sampling data (8134 samples) in which airborne MDI concentrations were measured in a wide variety of manufacturing processes that use either polymeric MDI (PMDI) or monomeric (pure) MDI. Data were collected during the period 1984 through 1999. A total of 606 surveys were conducted for 251 companies at 317 facilities. The database includes 3583 personal (breathing zone) samples and 4551 area samples. Data demonstrate that workplace airborne MDI concentrations are extremely low in a majority of the manufacturing operations. Most (74.6%) of the airborne MDI concentrations measured in the personal samples were nondetectable, i.e., below the limits of quantification (LOQs). A variety of validated industrial hygiene sampling/analytical methods were used for data collection; most are modifications of OSHA Method 47. The LOQs for these methods ranged from 0.1-0.5 microg/sample. The very low vapor pressures of both monomeric MDI and PMDI largely explain the low airborne concentrations found in most operations. However, processes or applications in which the chemical is sprayed or heated may result in higher airborne concentrations and higher exposure potentials if appropriate control measures are not implemented. Data presented in this article will be a useful reference for employers in helping them to manage their health and safety program as it relates to respiratory protection during MDI/PMDI applications.

  4. The biobank of the Norwegian mother and child cohort Study: A resource for the next 100 years

    PubMed Central

    Rønningen, Kjersti S.; Paltiel, Liv; Meltzer, Helle M.; Nordhagen, Rannveig; Lie, Kari K.; Hovengen, Ragnhild; Haugen, Margaretha; Nystad, Wenche; Magnus, Per; Hoppin, Jane A.

    2007-01-01

    Introduction Long-term storage of biological materials is a critical component of any epidemiological study. In designing specimen repositories, efforts need to balance future needs for samples with logistical constraints necessary to process and store samples in a timely fashion. Objectives In the Norwegian Mother and Child Cohort Study (MoBa), the Biobank was charged with long-term storage of more than 380,000 biological samples from pregnant women, their partners and their children for up to 100 years. Methods Biological specimens include whole blood, plasma, DNA and urine; samples are collected at 50 hospitals in Norway. All samples are sent via ordinary mail to the Biobank in Oslo where the samples are registered, aliquoted and DNA extracted. DNA is stored at −20 °C while whole blood, urine and plasma are stored at − 80 °C. Results As of July 2006, over 227,000 sample sets have been collected, processed and stored at the Biobank. Currently 250–300 sets are received daily. An important part of the Biobank is the quality control program. Conclusion With the unique combination of biological specimens and questionnaire data, the MoBa Study will constitute a resource for many future investigations of the separate and combined effects of genetic, environmental factors on pregnancy outcome and on human morbidity, mortality and health in general. PMID:17031521

  5. 78 FR 53005 - Agency Information Collection Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-27

    ... simulation studies in the past. Businesses are ineligible for the sample and will not be contacted. Number of Responses: Each respondent will complete the process once. Total Annual Burden Hours: It is estimated that...

  6. Reading in Able and Disabled Readers from around the World: Same or Different? An Illustration from a Study of Reading-Related Processes in a Swahili Sample of Siblings

    ERIC Educational Resources Information Center

    Grigorenko, Elena L.; Ngorosho, Damaris; Jukes, Matthew; Bundy, Donald

    2006-01-01

    In this article, we discuss two characteristics of the majority of current behaviour- and molecular-genetic studies of reading ability and disability, specifically, the ascertainment strategies and the populations from which samples are selected. In the context of this discussion, we present data that we collected on a sample of Swahili-speaking…

  7. A prioritization and analysis strategy for environmental surveillance results.

    PubMed

    Shyr, L J; Herrera, H; Haaker, R

    1997-11-01

    DOE facilities are required to conduct environmental surveillance to verify that facility operations are operated within the approved risk envelope and have not caused undue risk to the public and the environment. Given a reduced budget, a strategy for analyzing environmental surveillance data was developed to set priorities for sampling needs. The radiological and metal data collected at Sandia National Laboratories, New Mexico, were used to demonstrate the analysis strategy. Sampling locations were prioritized for further investigation and the needs for routine sampling. The process of data management, analysis, prioritization, and presentation has been automated through a custom-designed computer tool. Data collected over years can be analyzed and summarized in a short table format for prioritization and decision making.

  8. Soil Geochemical Data for the Wyoming Landscape Conservation Initiative Study Area

    USGS Publications Warehouse

    Smith, David B.; Ellefsen, Karl J.

    2010-01-01

    In 2008, soil samples were collected at 139 sites throughout the Wyoming Landscape Conservation Initiative study area in southwest Wyoming. These samples, representing a density of 1 site per 440 square kilometers, were collected from a depth of 0-5 cm and analyzed for a suite of more than 40 major and trace elements following a near-total multi-acid extraction. In addition, soil pH, electrical conductivity, total nitrogen, total and organic carbon, and sodium adsorption ratio were determined. The resulting data set provides a baseline for detecting changes in soil composition that might result from natural processes or anthropogenic activities. This report describes the sampling and analytical protocols used, and makes available all the soil geochemical data generated in the study.

  9. Personal exposures to asbestos fibers during brake maintenance of passenger vehicles.

    PubMed

    Cely-García, María Fernanda; Sánchez, Mauricio; Breysse, Patrick N; Ramos-Bonilla, Juan P

    2012-11-01

    Brake linings and brake pads are among the asbestos-containing products that are readily available in Colombia. When sold separated from their support, brake linings require extensive manipulation involving several steps that include drilling, countersinking, riveting, bonding, cutting, beveling, and grinding. Without this manipulation, brake linings cannot be installed in a vehicle. The manipulation process may release asbestos fibers, which may expose brake mechanics to the fibers. Three brake repair shops located in Bogotá (Colombia) were sampled for 3 or 4 consecutive days using US National Institute for Occupational Safety and Health (NIOSH) methods 7400 and 7402. Standard procedures for quality control were followed during the sampling process, and asbestos samples were analyzed by an American Industrial Hygiene Association accredited laboratory. Personal samples were collected to assess full-shift and short-term exposures. Area samples were also collected close to the brake-lining manipulation equipment and within office facilities. Activities were documented during the sampling process. Using Phase Contrast Microscopy Equivalent counts to estimate air asbestos concentrations, all personal samples [i.e. 8-h time-weighted averages (TWAs) and 30-min personal samples] were in compliance with the US Occupational Safety and Health Administration standards. Personal asbestos concentrations based on transmission electron microscopy counts were extremely high, ranging from 0.006 to 3.493 f cm(-3) for 8-h TWA and from 0.015 to 8.835 f cm(-3) for 30-min samples. All asbestos fibers detected were chrysotile. Cleaning facilities and grinding linings resulted in the highest asbestos exposures based on transmission electron microscopy counts. There were also some samples that did not comply with the NIOSH's recommended exposure limits. The results indicate that the brake mechanics sampled are exposed to extremely high asbestos concentrations (i.e. based on transmission electron microscopy counts), suggesting that this occupational group could be at excess risk of asbestos-related diseases.

  10. Blood gas testing and related measurements: National recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Dukić, Lora; Kopčinović, Lara Milevoj; Dorotić, Adrijana; Baršić, Ivana

    2016-10-15

    Blood gas analysis (BGA) is exposed to risks of errors caused by improper sampling, transport and storage conditions. The Clinical and Laboratory Standards Institute (CLSI) generated documents with recommendations for avoidance of potential errors caused by sample mishandling. Two main documents related to BGA issued by the CLSI are GP43-A4 (former H11-A4) Procedures for the collection of arterial blood specimens; approved standard - fourth edition, and C46-A2 Blood gas and pH analysis and related measurements; approved guideline - second edition. Practices related to processing of blood gas samples are not standardized in the Republic of Croatia. Each institution has its own protocol for ordering, collection and analysis of blood gases. Although many laboratories use state of the art analyzers, still many preanalytical procedures remain unchanged. The objective of the Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM) is to standardize the procedures for BGA based on CLSI recommendations. The Working Group for Blood Gas Testing as part of the Committee for the Scientific Professional Development of the CSMBLM prepared a set of recommended protocols for sampling, transport, storage and processing of blood gas samples based on relevant CLSI documents, relevant literature search and on the results of Croatian survey study on practices and policies in acid-base testing. Recommendations are intended for laboratory professionals and all healthcare workers involved in blood gas processing.

  11. Blood gas testing and related measurements: National recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine

    PubMed Central

    Dukić, Lora; Kopčinović, Lara Milevoj; Dorotić, Adrijana; Baršić, Ivana

    2016-01-01

    Blood gas analysis (BGA) is exposed to risks of errors caused by improper sampling, transport and storage conditions. The Clinical and Laboratory Standards Institute (CLSI) generated documents with recommendations for avoidance of potential errors caused by sample mishandling. Two main documents related to BGA issued by the CLSI are GP43-A4 (former H11-A4) Procedures for the collection of arterial blood specimens; approved standard – fourth edition, and C46-A2 Blood gas and pH analysis and related measurements; approved guideline – second edition. Practices related to processing of blood gas samples are not standardized in the Republic of Croatia. Each institution has its own protocol for ordering, collection and analysis of blood gases. Although many laboratories use state of the art analyzers, still many preanalytical procedures remain unchanged. The objective of the Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM) is to standardize the procedures for BGA based on CLSI recommendations. The Working Group for Blood Gas Testing as part of the Committee for the Scientific Professional Development of the CSMBLM prepared a set of recommended protocols for sampling, transport, storage and processing of blood gas samples based on relevant CLSI documents, relevant literature search and on the results of Croatian survey study on practices and policies in acid-base testing. Recommendations are intended for laboratory professionals and all healthcare workers involved in blood gas processing. PMID:27812301

  12. An overview of the Software Engineering Laboratory

    NASA Technical Reports Server (NTRS)

    1994-01-01

    This report describes the background and structure of the SEL organization, the SEL process improvement approach, and its experimentation and data collection process. Results of some sample SEL studies are included. It includes a discussion of the overall implication of trends observed over 17 years of process improvement efforts and looks at the return on investment based on a comparison of total investment in process improvement with the measurable improvements seen in the organization's software product.

  13. Utility of capillary microsampling for rat pharmacokinetic studies: Comparison of tail-vein bleed to jugular vein cannula sampling.

    PubMed

    Korfmacher, Walter; Luo, Yongyi; Ho, Stacy; Sun, Wei; Shen, Liduo; Wang, Jie; Wu, Zhongtao; Guo, Yang; Snow, Gregory; O'Shea, Thomas

    2015-01-01

    Serial sampling methods have been used for rat pharmacokinetic (PK) studies for over 20 years. Currently, it is still common to take 200-250 μL of blood at each timepoint when performing a PK study in rats and using serial sampling. While several techniques have been employed for collecting blood samples from rats, there is only limited published data to compare these methods. Recently, microsampling (≤ 50 μL) techniques have been reported as an alternative process for collecting blood samples from rats. In this report, five compounds were dosed orally into rats. For three proprietary compounds, jugular vein cannula (JVC) sampling was used to collect whole blood and plasma samples and capillary microsampling (CMS) was used to collect blood samples from the tail vein of the same animal. For the two other compounds, marketed drugs fluoxetine and glipizide, JVC sampling was used to collect both whole blood and blood CMS samples while tail-vein sampling from the same rats was also used to collect both whole blood and blood CMS samples. For the three proprietary compounds, the blood AUC as well as the blood concentration-time profile that were obtained from the tail vein were different from those obtained via JVC sampling. For fluoxetine, the blood total exposure (AUC) was not statistically different when comparing tail-vein sampling to JVC sampling, however the blood concentration-time profile that was obtained from the tail vein was different than the one obtained from JVC sampling. For glipizide, the blood AUC and concentration-time profile were not statistically different when comparing the tail-vein sampling to the JVC sampling. For both fluoxetine and glipizide, the blood concentration profiles obtained from CMS were equivalent to the blood concentration profiles obtained from the standard whole blood sampling, collected at the same sampling site. The data in this report provide strong evidence that blood CMS is a valuable small volume blood sampling approach for rats and that it provides results for test compound concentrations that are equivalent to those obtained from traditional whole blood sampling. The data also suggest that for some compounds, the concentration-time profile that is obtained for a test compound based on sampling from a rat tail vein may be different from that obtained from rat JVC sampling. In some cases, this shift in the concentration-time profile will result in different PK parameters for the test compound. Based on these observations, it is recommended that a consistent blood sampling method should be used for serial microsampling in discovery rat PK studies when testing multiple new chemical entities. If the rat tail vein sampling method is selected for PK screening, then conducting a bridging study on the lead compound is recommended to confirm that the rat PK obtained from JVC sampling is comparable to the tail-vein sampling. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Geochemical and radiological characterization of soils from former radium processing sites.

    PubMed

    Landa, E R

    1984-02-01

    Soil samples were collected from former radium processing sites in Denver, CO, and East Orange, NJ. Particle-size separations and radiochemical analyses of selected samples showed that while the greatest contents of both 226Ra and U were generally found in the finest (less than 45 micron) fraction, the pattern was not always of progressive increase in radionuclide content with decreasing particle size. Leaching tests on these samples showed a large portion of the 226Ra and U to be soluble in dilute hydrochloric acid. Radon-emanation coefficients measured for bulk samples of contaminated soil were about 20%. Recovery of residual uranium and vanadium, as an adjunct to any remedial action program, appears unlikely due to economic considerations.

  15. Off-Site Radiation Exposure Review Project: Phase 2 soils program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McArthur, R.D.; Miller, F.L. Jr.

    1989-12-01

    To help estimate population doses of radiation from fallout originating at the Nevada Test Site, soil samples were collected throughout the western United States. Each sample was prepared by drying and ball-milling, then analyzed by gamma-spectrometry to determine the amount of {sup 137}Cs it contained. Most samples were also analyzed by chemical separation and alpha-spectrometry to determine {sup 239 + 240}Pu and by isotope mass spectroscopy to determine the ratios of {sup 240}Pu to {sup 239}Pu and {sup 241}Pu to {sup 239}Pu. The total inventories of cesium and plutonium at 171 sites were computed from the results. This report describesmore » the sample collection, processing, and analysis, presents the analytical results, and assesses the quality of the data. 10 refs., 9 figs., 12 tabs.« less

  16. Working Up a Good Sweat – The Challenges of Standardising Sweat Collection for Metabolomics Analysis

    PubMed Central

    Hussain, Joy N; Mantri, Nitin; Cohen, Marc M

    2017-01-01

    Introduction Human sweat is a complex biofluid of interest to diverse scientific fields. Metabolomics analysis of sweat promises to improve screening, diagnosis and self-monitoring of numerous conditions through new applications and greater personalisation of medical interventions. Before these applications can be fully developed, existing methods for the collection, handling, processing and storage of human sweat need to be revised. This review presents a cross-disciplinary overview of the origins, composition, physical characteristics and functional roles of human sweat, and explores the factors involved in standardising sweat collection for metabolomics analysis. Methods A literature review of human sweat analysis over the past 10 years (2006–2016) was performed to identify studies with metabolomics or similarly applicable ‘omics’ analysis. These studies were reviewed with attention to sweat induction and sampling techniques, timing of sweat collection, sweat storage conditions, laboratory derivation, processing and analytical platforms. Results Comparative analysis of 20 studies revealed numerous factors that can significantly impact the validity, reliability and reproducibility of sweat analysis including: anatomical site of sweat sampling, skin integrity and preparation; temperature and humidity at the sweat collection sites; timing and nature of sweat collection; metabolic quenching; transport and storage; qualitative and quantitative measurements of the skin microbiota at sweat collection sites; and individual variables such as diet, emotional state, metabolic conditions, pharmaceutical, recreational drug and supplement use. Conclusion Further development of standard operating protocols for human sweat collection can open the way for sweat metabolomics to significantly add to our understanding of human physiology in health and disease. PMID:28798503

  17. A Multivariate Evaluation of Factors Affecting the Quality of Freshly Frozen Tissue Specimens.

    PubMed

    Wang, Tong-Hong; Chen, Chin-Chuan; Liang, Kung-Hao; Chen, Chi-Yuan; Chuang, Wen-Yu; Ueng, Shir-Hwa; Chu, Pao-Hsien; Huang, Chung-Guei; Chen, Tse-Ching; Hsueh, Chuen

    2017-08-01

    Well-prepared and preserved freshly frozen specimens are indispensable materials for clinical studies. To manage specimen quality and to understand the factors potentially affecting specimen quality during preservation processes, we analyzed the quality of RNA and genomic DNA of various tissues collected between 2002 and 2011 in Linkou Chang Gung Memorial Hospital, Taiwan. During this period, a total of 1059 freshly frozen specimens from eight major cancer categories were examined. It was found that preservation duration, organ origin, and tissue type could all influence the quality of RNA samples. The increased preservation period correlated with decreased RNA quality; the brain, breast, and stomach RNA specimens displayed faster degradation rates than those of other organs, and RNA specimens isolated from tumor tissues were apparently more stable than those of other tissues. These factors could all be used as quality predictors of RNA quality. In contrast, almost all analyses revealed that the genomic DNA samples had good quality, which was not influenced by the aforementioned factors. The results assisted us in determining preservation factors that affect specimen quality, which could provide evidence for improving processes of sample collection and preservation. Furthermore, the results are also useful for researchers to adopt as the evaluation criteria for choosing specimen collection and preservation strategies.

  18. Data Validation Package - July 2016 Groundwater Sampling at the Gunnison, Colorado, Disposal Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Linard, Joshua; Campbell, Sam

    Groundwater sampling at the Gunnison, Colorado, Disposal Site is conducted every 5 years to monitor disposal cell performance. During this event, samples were collected from eight monitoring wells as specified in the 1997 Long-Term Surveillance Plan for the Gunnison, Colorado, Disposal Site. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for US Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and­ analysis-plan-us-department-energy-office-legacy-management-sites). Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. A duplicate sample was collected from location 0723. Water levels were measured at all monitoring wells thatmore » were sampled and seven additional wells. The analytical data and associated qualifiers can be viewed in environmental database reports and are also available for viewing with dynamic mapping via the GEMS (Geospatial Environmental Mapping System) website at http://gems.lm.doe.gov/#. No issues were identified during the data validation process that require additional action or follow-up.« less

  19. Digital Curation of Marine Physical Samples at Ocean Networks Canada

    NASA Astrophysics Data System (ADS)

    Jenkyns, R.; Tomlin, M. C.; Timmerman, R.

    2015-12-01

    Ocean Networks Canada (ONC) has collected hundreds of geological, biological and fluid samples from the water column and seafloor during its maintenance expeditions. These samples have been collected by Remotely Operated Vehicles (ROVs), divers, networked and autonomously deployed instruments, and rosettes. Subsequent measurements are used for scientific experiments, calibration of in-situ and remote sensors, monitoring of Marine Protected Areas, and environment characterization. Tracking the life cycles of these samples from collection to dissemination of results with all the pertinent documents (e.g., protocols, imagery, reports), metadata (e.g., location, identifiers, purpose, method) and data (e.g., measurements, taxonomic classification) is a challenge. The initial collection of samples is normally documented in SeaScribe (an ROV dive logging tool within ONC's Oceans 2.0 software) for which ONC has defined semantics and syntax. Next, samples are often sent to individual scientists and institutions (e.g., Royal BC Museum) for processing and storage, making acquisition of results and life cycle metadata difficult. Finally, this information needs to be retrieved and collated such that multiple user scenarios can be addressed. ONC aims to improve and extend its digital infrastructure for physical samples to support this complex array of samples, workflows and applications. However, in order to promote effective data discovery and exchange, interoperability and community standards must be an integral part of the design. Thus, integrating recommendations and outcomes of initiatives like the EarthCube iSamples working groups are essential. Use cases, existing tools, schemas and identifiers are reviewed, while remaining gaps and challenges are identified. The current status, selected approaches and possible future directions to enhance ONC's digital infrastructure for each sample type are presented.

  20. The Effect of Pre-Analytical Variability on the Measurement of MRM-MS-Based Mid- to High-Abundance Plasma Protein Biomarkers and a Panel of Cytokines

    PubMed Central

    Aguilar-Mahecha, Adriana; Kuzyk, Michael A.; Domanski, Dominik; Borchers, Christoph H.; Basik, Mark

    2012-01-01

    Blood sample processing and handling can have a significant impact on the stability and levels of proteins measured in biomarker studies. Such pre-analytical variability needs to be well understood in the context of the different proteomics platforms available for biomarker discovery and validation. In the present study we evaluated different types of blood collection tubes including the BD P100 tube containing protease inhibitors as well as CTAD tubes, which prevent platelet activation. We studied the effect of different processing protocols as well as delays in tube processing on the levels of 55 mid and high abundance plasma proteins using novel multiple-reaction monitoring-mass spectrometry (MRM-MS) assays as well as 27 low abundance cytokines using a commercially available multiplexed bead-based immunoassay. The use of P100 tubes containing protease inhibitors only conferred proteolytic protection for 4 cytokines and only one MRM-MS-measured peptide. Mid and high abundance proteins measured by MRM are highly stable in plasma left unprocessed for up to six hours although platelet activation can also impact the levels of these proteins. The levels of cytokines were elevated when tubes were centrifuged at cold temperature, while low levels were detected when samples were collected in CTAD tubes. Delays in centrifugation also had an impact on the levels of cytokines measured depending on the type of collection tube used. Our findings can help in the development of guidelines for blood collection and processing for proteomic biomarker studies. PMID:22701622

  1. The effect of pre-analytical variability on the measurement of MRM-MS-based mid- to high-abundance plasma protein biomarkers and a panel of cytokines.

    PubMed

    Aguilar-Mahecha, Adriana; Kuzyk, Michael A; Domanski, Dominik; Borchers, Christoph H; Basik, Mark

    2012-01-01

    Blood sample processing and handling can have a significant impact on the stability and levels of proteins measured in biomarker studies. Such pre-analytical variability needs to be well understood in the context of the different proteomics platforms available for biomarker discovery and validation. In the present study we evaluated different types of blood collection tubes including the BD P100 tube containing protease inhibitors as well as CTAD tubes, which prevent platelet activation. We studied the effect of different processing protocols as well as delays in tube processing on the levels of 55 mid and high abundance plasma proteins using novel multiple-reaction monitoring-mass spectrometry (MRM-MS) assays as well as 27 low abundance cytokines using a commercially available multiplexed bead-based immunoassay. The use of P100 tubes containing protease inhibitors only conferred proteolytic protection for 4 cytokines and only one MRM-MS-measured peptide. Mid and high abundance proteins measured by MRM are highly stable in plasma left unprocessed for up to six hours although platelet activation can also impact the levels of these proteins. The levels of cytokines were elevated when tubes were centrifuged at cold temperature, while low levels were detected when samples were collected in CTAD tubes. Delays in centrifugation also had an impact on the levels of cytokines measured depending on the type of collection tube used. Our findings can help in the development of guidelines for blood collection and processing for proteomic biomarker studies.

  2. Salmonella spp. and Extended-Spectrum Cephalosporin-Resistant Escherichia coli Frequently Contaminate Broiler Chicken Transport Cages of an Organic Production Company.

    PubMed

    Mollenkopf, Dixie F; De Wolf, Brittany; Feicht, Sydnee M; Cenera, Johana K; King, Christy A; van Balen, Joany C; Wittum, Thomas E

    2018-06-06

    Antimicrobial resistant bacteria in retail meat pose a health hazard to the public, as does contamination of these products with Salmonella. Our aim was to determine the prevalence of Salmonella as well as Escherichia coli expressing AmpC and extended-spectrum beta-lactamase (ESBL) resistance phenotypes contaminating broiler transport cages and fresh, retail ground chicken meat. Sterile gauze sponges were used to collect duplicate cage floor samples from transport trailers that deliver market-ready birds to a single organic poultry-processing facility. With the exception of the first visit (n = 25), 50 duplicate cage floor samples were collected using moistened sterile gauze sponges on each of nine weekly visits during May, June, and July 2013. Additionally, fresh, retail ground chicken meat was sampled at each weekly visit from an on-site retail store located at the same processing facility. A total of 425 cage swabs and 72 ground chicken aliquots from 24 retail packages were collected and screened for the presence of Salmonella as well as E. coli expressing resistance to extended-spectrum cephalosporins using selective culture. We recovered Salmonella from 26.1% of cage swab samples and 2.8% of retail meat samples. E. coli expressing AmpC and ESBL resistance phenotypes were recovered from 84.9% and 22.6% of cage swabs and 77.8% and 11.1% of fresh, retail ground meat samples, respectively. Our results suggest that transport cages could potentially act as a source of broiler exposure to both Salmonella and enteric bacteria resistant to important antimicrobial drugs as they are transported for entry into the food supply as fresh, retail meat products.

  3. Collecting Research-Grade Data With Volunteers: A Case Study from Montana's Wilderness to the Sea

    NASA Astrophysics Data System (ADS)

    Kautz, M.

    2016-12-01

    Collecting Research-Grade Data With Volunteers: A Case Study from Montana's Wilderness Waterways to the SeaKautz, M (1), Barrows, A (2)(1) Adventurers and Scientists for Conservation. Bozeman, Montana, United States - mike@adventureandscience.org(2) College of the Atlantic. Bar Harbor, Maine, United States - abby.barrows@coa.eduSince World War II, global plastic production and consumption has increased dramatically. Plastics released into the environment may break down into smaller pieces through physical, biological and chemical processes. These small particles, referred to as microplastics, are less than 5mm in size and are a pollutant of emerging concern in both marine and freshwater environments. Since 2013, researcher Abigail Barrows and ASC have been conducting a global survey of microplastic distribution by utilizing the outdoor skills of adventurers. ASC recruits, trains and manages volunteers with specialized skills (surfers, long-distance open-ocean rowers, sailors, hikers, mountaineers, kayakers and others) to collect marine and freshwater samples from remote environments. Of the nearly 1500 samples collected worldwide to date (from areas as remote as the edge of Antarctica and the wilderness of Alaska) 90% contain microplastic, with an average of 8 pieces/1L of water. Samples are also in preparation for micro-Raman spectroscopy to determine source materials. In 2016 and 2017 the survey is focusing on freshwater around the globe. In the United States samples are being collected from the length of the 4th longest river system in the world, the Missouri-Mississippi. ASC has adventurous citizen scientists sampling in the mountain headwaters near Yellowstone National Park to the delta of the Mississippi River near New Orleans. This citizen-driven observation allows research at a geographic scale simply not possible through traditional methods. ASC works closely with Barrows and other researchers to develop water sampling protocols that allow volunteers to collect research grade data. This includes the use of POV cameras to review volunteers' sample collection methods, incorporating self-assessment into data collection, online training and refreshers, and app-based field data recording.

  4. Spatial distributions and seasonal variations of organochlorine pesticides in water and soil samples in Bolu, Turkey.

    PubMed

    Karadeniz, Hatice; Yenisoy-Karakaş, Serpil

    2015-03-01

    In this study, a total of 75 water samples (38 groundwater and 37 surface water samples) and 54 surface soil samples were collected from the five districts of Bolu, which is located in the Western Black Sea Region of Turkey in the summer season of 2009. In the autumn season, 17 water samples (surface water and groundwater samples) and 17 soil samples were collected within the city center to observe the seasonal changes of organochlorine pesticides (OCPs). Groundwater and surface water samples were extracted using solid phase extraction. Soil samples were extracted ultrasonically. Sixteen OCP compounds in the standard solution were detected by a gas chromatography-electron capture detector (GC-ECD). Therefore, the method validation was performed for those 16 OCP compounds. However, 13 OCP compounds could be observed in the samples. The concentrations of most OCPs were higher in samples collected in the summer than those in the autumn. The most frequently observed pesticides were endosulfan sulfate and 4,4'-dichlorodiphenyltrichloroethane (DDT) in groundwater samples, α-HCH in surface water samples, and endosulfan sulfate in soil samples. The average concentration of endosulfan sulfate was the highest in water and soil samples. Compared to the literature values, the average concentrations in this study were lower values. Spatial distribution of OCPs was evaluated with the aid of contour maps for the five districts of Bolu. Generally, agricultural processes affected the water and soil quality in the region. However, non-agricultural areas were also affected by pesticides. The concentrations of pesticides were below the legal limits of European directives for each pesticide.

  5. Understanding the behavior of Giardia and Cryptosporidium in an urban watershed: Explanation and application of techniques to collect and evaluate monitoring data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crockett, C.S.; Haas, C.N.

    1996-11-01

    Due to current proposed regulations requiring monitoring for protozoans and demonstration of adequate protozoan removal depending on source water concentrations detected, many utilities are considering or are engaged in protozoan monitoring activities within their watershed so that proper watershed management and treatment modifications can reduce their impact on drinking water safety and quality. However, due to the difficulties associated with the current analytical methods and sample collection many sampling efforts collect data that cannot be interpreted or lack the tools to interpret the information obtained. Therefore, it is necessary to determine how to develop an effective sampling program tailored tomore » a utility`s specific needs to provide interpretable data and develop tools for evaluating such data. The following case study describes the process in which a utility learned how to collect and interpret monitoring data for their specific needs and provides concepts and tools which other utilities can use to aid in their own macro and microwatershed management efforts.« less

  6. Design and evaluation of a field study on the contamination of selected volatile organic compounds and wastewater-indicator compounds in blanks and groundwater samples

    USGS Publications Warehouse

    Thiros, Susan A.; Bender, David A.; Mueller, David K.; Rose, Donna L.; Olsen, Lisa D.; Martin, Jeffrey D.; Bernard, Bruce; Zogorski, John S.

    2011-01-01

    The Field Contamination Study (FCS) was designed to determine the field processes that tend to result in clean field blanks and to identify potential sources of contamination to blanks collected in the field from selected volatile organic compounds (VOCs) and wastewater-indicator compounds (WICs). The VOCs and WICs analyzed in the FCS were detected in blanks collected by the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) Program during 1996–2008 and 2002–08, respectively. To minimize the number of variables, the study required ordering of supplies just before sampling, storage of supplies and equipment in clean areas, and use of adequate amounts of purge-and-trap volatile-grade methanol and volatile pesticide-grade blank water (VPBW) to clean sampling equipment and to collect field blanks.Blanks and groundwater samples were collected during 2008–09 at 16 sites, which were a mix of water-supply and monitoring wells, located in 9 States. Five different sample types were collected for the FCS at each site: (1) a source-solution blank collected at the USGS National Water Quality Laboratory (NWQL) using laboratory-purged VPBW, (2) source-solution blanks collected in the field using laboratory-purged VPBW, (3) source-solution blanks collected in the field using field-purged VPBW, (4) a field blank collected using field-purged VPBW, and (5) a groundwater sample collected from a well. The source-solution blank and field-blank analyses were used to identify, quantify, and document extrinsic contamination and to help determine the sources and causes of data-quality problems that can affect groundwater samples.Concentrations of compounds detected in FCS analyses were quantified and results were stored in the USGS National Water Information System database after meeting rigorous identification and quantification criteria. The study also utilized information provided by laboratory analysts about evidence indicating the presence of selected compounds, using less rigorous identification criteria than is required for reporting data to the National Water Information System database. For the FCS, these data are considered adequate to indicate "evidence of presence," and were used only for diagnostic purposes. Evidence of VOCs and WICs at low concentrations near or less than the long-term method detection level can indicate a contamination problem that could affect future datasets if method detection levels were ever to be lowered.

  7. Campylobacter in Broiler Chicken and Broiler Meat in Sri Lanka: Influence of Semi-Automated vs. Wet Market Processing on Campylobacter Contamination of Broiler Neck Skin Samples.

    PubMed

    Kottawatta, Kottawattage S A; Van Bergen, Marcel A P; Abeynayake, Preeni; Wagenaar, Jaap A; Veldman, Kees T; Kalupahana, Ruwani S

    2017-11-29

    Broiler meat can become contaminated with Campylobacter of intestinal origin during processing. The present study aimed to identify the prevalence of Campylobacter in broiler flocks and meat contamination at retail shops, and determine the influence of semi-automated and wet market processing on Campylobacter contamination of neck skin samples. Samples were collected from semi-automated plants ( n = 102) and wet markets ( n = 25). From each batch of broilers, pooled caecal samples and neck skin samples were tested for Campylobacter . Broiler meat purchased from retail outlets ( n = 37) was also tested. The prevalence of Campylobacter colonized broiler flocks was 67%. The contamination of meat at retail was 59%. Both semi-automated and wet market processing resulted to contaminate the broiler neck skins to the levels of 27.4% and 48%, respectively. When Campylobacter -free broiler flocks were processed in semi-automated facilities 15% (5/33) of neck skin samples became contaminated by the end of processing whereas 25% (2/8) became contaminated after wet market processing. Characterization of isolates revealed a higher proportion of C. coli compared to C. jejuni . Higher proportions of isolates were resistant to important antimicrobials. This study shows the importance of Campylobacter in poultry industry in Sri Lanka and the need for controlling antimicrobial resistance.

  8. Campylobacter in Broiler Chicken and Broiler Meat in Sri Lanka: Influence of Semi-Automated vs. Wet Market Processing on Campylobacter Contamination of Broiler Neck Skin Samples

    PubMed Central

    Kottawatta, Kottawattage S. A.; Van Bergen, Marcel A. P.; Abeynayake, Preeni; Wagenaar, Jaap A.; Veldman, Kees T.; Kalupahana, Ruwani S.

    2017-01-01

    Broiler meat can become contaminated with Campylobacter of intestinal origin during processing. The present study aimed to identify the prevalence of Campylobacter in broiler flocks and meat contamination at retail shops, and determine the influence of semi-automated and wet market processing on Campylobacter contamination of neck skin samples. Samples were collected from semi-automated plants (n = 102) and wet markets (n = 25). From each batch of broilers, pooled caecal samples and neck skin samples were tested for Campylobacter. Broiler meat purchased from retail outlets (n = 37) was also tested. The prevalence of Campylobacter colonized broiler flocks was 67%. The contamination of meat at retail was 59%. Both semi-automated and wet market processing resulted to contaminate the broiler neck skins to the levels of 27.4% and 48%, respectively. When Campylobacter-free broiler flocks were processed in semi-automated facilities 15% (5/33) of neck skin samples became contaminated by the end of processing whereas 25% (2/8) became contaminated after wet market processing. Characterization of isolates revealed a higher proportion of C. coli compared to C. jejuni. Higher proportions of isolates were resistant to important antimicrobials. This study shows the importance of Campylobacter in poultry industry in Sri Lanka and the need for controlling antimicrobial resistance. PMID:29186018

  9. BIOAEROSOL SAMPLE COLLECTION METHODS

    EPA Science Inventory

    Bioaerosols are generally defined as those airborne particles that are living or originate from living organisms. Bioaerosol inhalation may result in a variety of lung diseases. Bioaerosols are recognized inhalation threats associated with waste management processes such as waste...

  10. Evaluating Core Quality for a Mars Sample Return Mission

    NASA Technical Reports Server (NTRS)

    Weiss, D. K.; Budney, C.; Shiraishi, L.; Klein, K.

    2012-01-01

    Sample return missions, including the proposed Mars Sample Return (MSR) mission, propose to collect core samples from scientifically valuable sites on Mars. These core samples would undergo extreme forces during the drilling process, and during the reentry process if the EEV (Earth Entry Vehicle) performed a hard landing on Earth. Because of the foreseen damage to the stratigraphy of the cores, it is important to evaluate each core for rock quality. However, because no core sample return mission has yet been conducted to another planetary body, it remains unclear as to how to assess the cores for rock quality. In this report, we describe the development of a metric designed to quantitatively assess the mechanical quality of any rock cores returned from Mars (or other planetary bodies). We report on the process by which we tested the metric on core samples of Mars analogue materials, and the effectiveness of the core assessment metric (CAM) in assessing rock core quality before and after the cores were subjected to shocking (g forces representative of an EEV landing).

  11. Acoustic Sample Deposition MALDI-MS (ASD-MALDI-MS): A Novel Process Flow for Quality Control Screening of Compound Libraries.

    PubMed

    Chin, Jefferson; Wood, Elizabeth; Peters, Grace S; Drexler, Dieter M

    2016-02-01

    In the early stages of drug discovery, high-throughput screening (HTS) of compound libraries against pharmaceutical targets is a common method to identify potential lead molecules. For these HTS campaigns to be efficient and successful, continuous quality control of the compound collection is necessary and crucial. However, the large number of compound samples and the limited sample amount pose unique challenges. Presented here is a proof-of-concept study for a novel process flow for the quality control screening of small-molecule compound libraries that consumes only minimal amounts of samples and affords compound-specific molecular data. This process employs an acoustic sample deposition (ASD) technique for the offline sample preparation by depositing nanoliter volumes in an array format onto microscope glass slides followed by matrix-assisted laser desorption/ionization mass spectrometric (MALDI-MS) analysis. An initial study of a 384-compound array employing the ASD-MALDI-MS workflow resulted in a 75% first-pass positive identification rate with an analysis time of <1 s per sample. © 2015 Society for Laboratory Automation and Screening.

  12. Concentrations of selected constituents in surface-water and streambed-sediment samples collected from streams in and near an area of oil and natural-gas development, south-central Texas, 2011-13

    USGS Publications Warehouse

    Opsahl, Stephen P.; Crow, Cassi L.

    2014-01-01

    During collection of streambed-sediment samples, additional samples from a subset of three sites (the SAR Elmendorf, SAR 72, and SAR McFaddin sites) were processed by using a 63-µm sieve on one aliquot and a 2-mm sieve on a second aliquot for PAH and n-alkane analyses. The purpose of analyzing PAHs and n-alkanes on a sample containing sand, silt, and clay versus a sample containing only silt and clay was to provide data that could be used to determine if these organic constituents had a greater affinity for silt- and clay-sized particles relative to sand-sized particles. The greater concentrations of PAHs in the <63-μm size-fraction samples at all three of these sites are consistent with a greater percentage of binding sites associated with fine-grained (<63 μm) sediment versus coarse-grained (<2 mm) sediment. The larger difference in total PAHs between the <2-mm and <63-μm size-fraction samples at the SAR Elmendorf site might be related to the large percentage of sand in the <2-mm size-fraction sample which was absent in the <63-μm size-fraction sample. In contrast, the <2-mm size-fraction sample collected from the SAR McFaddin site contained very little sand and was similar in particle-size composition to the <63-μm size-fraction sample.

  13. Intensified Sampling in Response to a Salmonella Heidelberg Outbreak Associated with Multiple Establishments Within a Single Poultry Corporation

    PubMed Central

    Defibaugh-Chavez, Stephanie; Douris, Aphrodite; Vetter, Danah; Atkinson, Richard; Kissler, Bonnie; Khroustalev, Allison; Robertson, Kis; Sharma, Yudhbir; Becker, Karen; Dessai, Uday; Antoine, Nisha; Allen, Latasha; Holt, Kristin; Gieraltowski, Laura; Wise, Matthew; Schwensohn, Colin

    2018-01-01

    Abstract On June 28, 2013, the Food Safety and Inspection Service (FSIS) was notified by the Centers for Disease Control and Prevention (CDC) of an investigation of a multistate cluster of illnesses of Salmonella enterica serovar Heidelberg. Since case-patients in the cluster reported consumption of a variety of chicken products, FSIS used a simple likelihood-based approach using traceback information to focus on intensified sampling efforts. This article describes the multiphased product sampling approach taken by FSIS when epidemiologic evidence implicated chicken products from multiple establishments operating under one corporation. The objectives of sampling were to (1) assess process control of chicken slaughter and further processing and (2) determine whether outbreak strains were present in products from these implicated establishments. As part of the sample collection process, data collected by FSIS personnel to characterize product included category (whole chicken and type of chicken parts), brand, organic or conventional product, injection with salt solutions or flavorings, and whether product was skinless or skin-on. From the period September 9, 2013, through October 31, 2014, 3164 samples were taken as part of this effort. Salmonella percent positive declined from 19.7% to 5.3% during this timeframe as a result of regulatory and company efforts. The results of intensified sampling for this outbreak investigation informed an FSIS regulatory response and corrective actions taken by the implicated establishments. The company noted that a multihurdle approach to reduce Salmonella in products was taken, including on-farm efforts such as environmental testing, depopulation of affected flocks, disinfection of affected houses, vaccination, and use of various interventions within the establishments over the course of several months. PMID:29638165

  14. Sources of psychrophilic and psychrotolerant clostridia causing spoilage of vacuum-packed chilled meats, as determined by PCR amplification procedure.

    PubMed

    Broda, D M; Boerema, J A; Brightwell, G

    2009-07-01

    To determine possible preslaughter and processing sources of psychrophilic and psychrotolerant clostridia causing spoilage of vacuum-packed chilled meats. Molecular methods based on the polymerase chain reaction (PCR) amplification of specific 16S rDNA fragments were used to detect the presence of Clostridium gasigenes, Clostridium estertheticum, Clostridium algidicarnis and Clostridium putrefaciens in a total of 357 samples collected from ten slaughter stock supply farms, slaughter stock, two lamb-processing plants, their environments, dressed carcasses and final vacuum-packed meat stored at -0.5 degrees C for 5(1/2) weeks. Clostridium gasigenes, C. estertheticum and C. algidicarnis/C. putrefaciens were commonly detected in farm, faeces, fleece and processing environmental samples collected at the slaughter floor operations prior to fleece removal, but all these micro-organisms were detected in only 4 out of 26 cooling floor and chiller environmental samples. One out of 42 boning room environmental samples tested positive for the presence of C. gasigenes and C. estertheticum, but 25 out of 42 of these samples were positive for C. algidicarnis/C. putrefaciens. Nearly all of the 31 faecal samples tested positive for the presence of C. gasigenes and C. estertheticum; however, only two of these samples were positive for C. algidicarnis and/or C. putrefaciens. Clostridial species that were subject to this investigation were frequently detected on chilled dressed carcasses. The major qualitative and quantitative differences between the results of PCR detection obtained with the primers specific for 'blown pack' -causing clostridia (C. gasigenes and C. estertheticum) and those obtained with primers specific for C. algidicarnis and C. putrefaciens suggest that the control of meat spoilage caused by different groups of meat clostridia is best approached individually for each group. This paper provides information significant for controlling meat spoilage-causing clostridia in the meat-processing plants.

  15. Alzheimer's disease cerebrospinal fluid biomarkers are not influenced by gravity drip or aspiration extraction methodology.

    PubMed

    Rembach, Alan; Evered, Lisbeth A; Li, Qiao-Xin; Nash, Tabitha; Vidaurre, Lesley; Fowler, Christopher J; Pertile, Kelly K; Rumble, Rebecca L; Trounson, Brett O; Maher, Sarah; Mooney, Francis; Farrow, Maree; Taddei, Kevin; Rainey-Smith, Stephanie; Laws, Simon M; Macaulay, S Lance; Wilson, William; Darby, David G; Martins, Ralph N; Ames, David; Collins, Steven; Silbert, Brendan; Masters, Colin L; Doecke, James D

    2015-11-19

    Cerebrospinal fluid (CSF) biomarkers, although of established utility in the diagnostic evaluation of Alzheimer's disease (AD), are known to be sensitive to variation based on pre-analytical sample processing. We assessed whether gravity droplet collection versus syringe aspiration was another factor influencing CSF biomarker analyte concentrations and reproducibility. Standardized lumbar puncture using small calibre atraumatic spinal needles and CSF collection using gravity fed collection followed by syringe aspirated extraction was performed in a sample of elderly individuals participating in a large long-term observational research trial. Analyte assay concentrations were compared. For the 44 total paired samples of gravity collection and aspiration, reproducibility was high for biomarker CSF analyte assay concentrations (concordance correlation [95%CI]: beta-amyloid1-42 (Aβ42) 0.83 [0.71 - 0.90]), t-tau 0.99 [0.98 - 0.99], and phosphorylated tau (p-tau) 0.82 [95 % CI 0.71 - 0.89]) and Bonferroni corrected paired sample t-tests showed no significant differences (group means (SD): Aβ42 366.5 (86.8) vs 354.3 (82.6), p = 0.10; t-tau 83.9 (46.6) vs 84.7 (47.4) p = 0.49; p-tau 43.5 (22.8) vs 40.0 (17.7), p = 0.05). The mean duration of collection was 10.9 minutes for gravity collection and <1 minute for aspiration. Our results demonstrate that aspiration of CSF is comparable to gravity droplet collection for AD biomarker analyses but could considerably accelerate throughput and improve the procedural tolerability for assessment of CSF biomarkers.

  16. Exhaled Breath Condensate Collection in the Mechanically Ventilated Patient

    PubMed Central

    Carter, Stewart R; Davis, Christopher S; Kovacs, Elizabeth J

    2012-01-01

    Collection of exhaled breath condensate (EBC) is a non-invasive means of sampling the airway-lining fluid of the lungs. EBC contains numerous measurable mediators, whose analysis could change the management of patients with certain pulmonary diseases. While initially popularized in investigations involving spontaneously breathing patients, an increasing number of studies have been performed using EBC in association with mechanical ventilation. Collection of EBC in mechanically ventilated patients follows basic principles of condensation, but is influenced by multiple factors. Effective collection requires selection of a collection device, adequate minute ventilation, low cooling temperatures, and sampling times of greater than ten minutes. Condensate can be contaminated by saliva, which needs to be filtered. Dilution of samples occurs secondary to distilled water in vapors and humidification in the ventilator circuit. Dilution factors may need to be employed when investigating non-volatile biomarkers. Storage and analysis should occur promptly at −70° C to −80° C to prevent rapid degradation of samples. The purpose of this review is to examine and describe methodologies and problems of EBC collection in mechanically ventilated patients. A straightforward and safe framework has been established to investigate disease processes in this population, yet technical aspects of EBC collection still exist that prevent clinical practicality of this technology. These include a lack of standardization of procedure and analysis of biomarkers, and of normal reference ranges for mediators in healthy individuals. Once these procedural aspects have been addressed, EBC could serve as a non-invasive alternative to invasive evaluation of lungs in mechanically ventilated patients. PMID:22398157

  17. USGS Blind Sample Project: monitoring and evaluating laboratory analytical quality

    USGS Publications Warehouse

    Ludtke, Amy S.; Woodworth, Mark T.

    1997-01-01

    The U.S. Geological Survey (USGS) collects and disseminates information about the Nation's water resources. Surface- and ground-water samples are collected and sent to USGS laboratories for chemical analyses. The laboratories identify and quantify the constituents in the water samples. Random and systematic errors occur during sample handling, chemical analysis, and data processing. Although all errors cannot be eliminated from measurements, the magnitude of their uncertainty can be estimated and tracked over time. Since 1981, the USGS has operated an independent, external, quality-assurance project called the Blind Sample Project (BSP). The purpose of the BSP is to monitor and evaluate the quality of laboratory analytical results through the use of double-blind quality-control (QC) samples. The information provided by the BSP assists the laboratories in detecting and correcting problems in the analytical procedures. The information also can aid laboratory users in estimating the extent that laboratory errors contribute to the overall errors in their environmental data.

  18. Blood meal analysis of tabanid fly after it biting the rare Sumatran rhinoceros

    PubMed Central

    Rovie-Ryan, Jeffrine Japning; Zainuddin, Zainal Zahari; Marni, Wahap; Ahmad, Abdul Hamid; Ambu, Laurentius N.; Payne, Junaidi

    2013-01-01

    Objective To demonstrate a noninvasive large mammalian genetic sampling method using blood meal obtained from a tabanid fly. Methods Blood meal was recovered from the abdomen of an engorged tabanid fly (Haematopota sp.) which was captured immediately after biting a Sumatran rhino in captivity. The blood was applied on to a Whatman FTA® blood card. Subsequent laboratory work was conducted to extract, amplify and sequence the DNA from the sample. Validation was done by sampling the hair follicles and blood samples from the rhinoceros and subjecting it to the same laboratory process. Results BLAST search and constructed phylogenetic trees confirmed the blood meal samples were indeed from the rhino. Conclusions This method could be used in the field application to noninvasively collect genetic samples. Collection of tabanids and other haematophagous arthropods (e.g. mosquitoes and ticks) and other blood-sucking parasites (e.g. leeches and worms) could also provide information on vector-borne diseases. PMID:23593586

  19. Elimination of bioweapons agents from forensic samples during extraction of human DNA.

    PubMed

    Timbers, Jason; Wilkinson, Della; Hause, Christine C; Smith, Myron L; Zaidi, Mohsin A; Laframboise, Denis; Wright, Kathryn E

    2014-11-01

    Collection of DNA for genetic profiling is a powerful means for the identification of individuals responsible for crimes and terrorist acts. Biologic hazards, such as bacteria, endospores, toxins, and viruses, could contaminate sites of terrorist activities and thus could be present in samples collected for profiling. The fate of these hazards during DNA isolation has not been thoroughly examined. Our goals were to determine whether the DNA extraction process used by the Royal Canadian Mounted Police eliminates or neutralizes these agents and if not, to establish methods that render samples safe without compromising the human DNA. Our results show that bacteria, viruses, and toxins were reduced to undetectable levels during DNA extraction, but endospores remained viable. Filtration of samples after DNA isolation eliminated viable spores from the samples but left DNA intact. We also demonstrated that contamination of samples with some bacteria, endospores, and toxins for longer than 1 h compromised the ability to complete genetic profiling. © 2014 American Academy of Forensic Sciences.

  20. High School and Beyond Transcripts Survey (1982). Data File User's Manual. Contractor Report.

    ERIC Educational Resources Information Center

    Jones, Calvin; And Others

    This data file user's manual documents the procedures used to collect and process high school transcripts for a large sample of the younger cohort (1980 sophomores) in the High School and Beyond survey. The manual provides the user with the technical assistance needed to use the computer file and also discusses the following: (1) sample design for…

  1. Microfossils from the Local Marine Environment. A Learning Experience for Coastal and Oceanic Awareness Studies, No. 219. [Project COAST].

    ERIC Educational Resources Information Center

    Delaware Univ., Newark. Coll. of Education.

    This unit on fossils is designed for junior high school students. Students collect a sediment sample, process the sample, and examine it for microfossils. The scientific classification and naming of microfossils is not stressed. Included in the materials are evaluation items, background materials for teachers, lists of needed materials, vocabulary…

  2. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks.

    PubMed

    Bernini, Patrizia; Bertini, Ivano; Luchinat, Claudio; Nincheri, Paola; Staderini, Samuele; Turano, Paola

    2011-04-01

    (1)H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0-4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  3. Collective relaxation processes in atoms, molecules and clusters

    NASA Astrophysics Data System (ADS)

    Kolorenč, Přemysl; Averbukh, Vitali; Feifel, Raimund; Eland, John

    2016-04-01

    Electron correlation is an essential driver of a variety of relaxation processes in excited atomic and molecular systems. These are phenomena which often lead to autoionization typically involving two-electron transitions, such as the well-known Auger effect. However, electron correlation can give rise also to higher-order processes characterized by multi-electron transitions. Basic examples include simultaneous two-electron emission upon recombination of an inner-shell vacancy (double Auger decay) or collective decay of two holes with emission of a single electron. First reports of this class of processes date back to the 1960s, but their investigation intensified only recently with the advent of free-electron lasers. High fluxes of high-energy photons induce multiple excitation or ionization of a system on the femtosecond timescale and under such conditions the importance of multi-electron processes increases significantly. We present an overview of experimental and theoretical works on selected multi-electron relaxation phenomena in systems of different complexity, going from double Auger decay in atoms and small molecules to collective interatomic autoionization processes in nanoscale samples.

  4. Identification of Sources of Endotoxin Exposure as Input for Effective Exposure Control Strategies.

    PubMed

    van Duuren-Stuurman, Birgit; Gröllers-Mulderij, Mariska; van de Runstraat, Annemieke; Duisterwinkel, Anton; Terwoert, Jeroen; Spaan, Suzanne

    2018-02-13

    Aim of the present study is to investigate the levels of endotoxins on product samples from potatoes, onions, and seeds, representing a relevant part of the agro-food industry in the Netherlands, to gather valuable insights in possibilities for exposure control measures early in the process of industrial processing of these products. Endotoxin levels on 330 products samples from companies representing the potato, onion, and seed (processing) industry (four potato-packaging companies, five potato-processing companies, five onion-packaging companies, and four seed-processing companies) were assessed using the Limulus Amboecyte Lysate (LAL) assay. As variation in growth conditions (type of soil, growth type) and product characteristics (surface roughness, dustiness, size, species) are assumed to influence the level of endotoxin on products, different types, and growth conditions were considered when collecting the samples. Additionally, waste material, rotten products, felt material (used for drying), and process water were collected. A large variation in the endotoxin levels was found on samples of potatoes, onions, and seeds (overall geometric standard deviation 17), in the range between 0.7 EU g-1 to 16400000 EU g-1. The highest geometric mean endotoxin levels were found in plant material (319600 EU g-1), followed by soil material (49100 EU g-1) and the outer side of products (9300 EU g-1), indicating that removal of plant and soil material early in the process would be an effective exposure control strategy. The high levels of endotoxins found in the limited number of samples from rotten onions indicate that these rotten onions should also be removed early in the process. Mean endotoxin levels found in waste material (only available for seed processing) is similar to the level found in soil material, although the range is much larger. On uncleaned seeds, higher endotoxin levels were found than on cleaned seeds, indicating that cleaning processes are important control measures and also that the waste material should be handled with care. Although endotoxin levels in batches of to-be-processed potatoes, onions, and seeds vary quite dramatically, it could be concluded that rotten products, plant material, and waste material contain particularly high endotoxin levels. This information was used to propose control measures to reduce exposure to endotoxins of workers during the production process. © The Author(s) 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  5. Differential Topic Models.

    PubMed

    Chen, Changyou; Buntine, Wray; Ding, Nan; Xie, Lexing; Du, Lan

    2015-02-01

    In applications we may want to compare different document collections: they could have shared content but also different and unique aspects in particular collections. This task has been called comparative text mining or cross-collection modeling. We present a differential topic model for this application that models both topic differences and similarities. For this we use hierarchical Bayesian nonparametric models. Moreover, we found it was important to properly model power-law phenomena in topic-word distributions and thus we used the full Pitman-Yor process rather than just a Dirichlet process. Furthermore, we propose the transformed Pitman-Yor process (TPYP) to incorporate prior knowledge such as vocabulary variations in different collections into the model. To deal with the non-conjugate issue between model prior and likelihood in the TPYP, we thus propose an efficient sampling algorithm using a data augmentation technique based on the multinomial theorem. Experimental results show the model discovers interesting aspects of different collections. We also show the proposed MCMC based algorithm achieves a dramatically reduced test perplexity compared to some existing topic models. Finally, we show our model outperforms the state-of-the-art for document classification/ideology prediction on a number of text collections.

  6. Human enteric viruses in groundwater indicate offshore transport of human sewage to coral reefs of the Upper Florida Keys.

    PubMed

    Futch, J Carrie; Griffin, Dale W; Lipp, Erin K

    2010-04-01

    To address the issue of human sewage reaching corals along the main reef of the Florida Keys, samples were collected from surface water, groundwater and coral [surface mucopolysaccharide layers (SML)] along a 10 km transect near Key Largo, FL. Samples were collected semi-annually between July 2003 and September 2005 and processed for faecal indicator bacteria (faecal coliform bacteria, enterococci and Clostridium perfringens) and human-specific enteric viruses (enterovirus RNA and adenovirus DNA) by (RT)-nested polymerase chain reaction. Faecal indicator bacteria concentrations were generally higher nearshore and in the coral SML. Enteric viruses were evenly distributed across the transect stations. Adenoviruses were detected in 37 of 75 samples collected (49.3%) whereas enteroviruses were only found in 8 of 75 samples (10.7%). Both viruses were detected twice as frequently in coral compared with surface water or groundwater. Offshore, viruses were most likely to be found in groundwater, especially during the wet summer season. These data suggest that polluted groundwater may be moving to the outer reef environment in the Florida Keys.

  7. Human enteric viruses in groundwater indicate offshore transport of human sewage to coral reefs of the Upper Florida Keys

    USGS Publications Warehouse

    Futch, J. Carrie; Griffin, Dale W.; Lipp, Erin K.

    2010-01-01

    To address the issue of human sewage reaching corals along the main reef of the Florida Keys, samples were collected from surface water, groundwater and coral [surface mucopolysaccharide layers (SML)] along a 10 km transect near Key Largo, FL. Samples were collected semi-annually between July 2003 and September 2005 and processed for faecal indicator bacteria (faecal coliform bacteria, enterococci and Clostridium perfringens) and human-specific enteric viruses (enterovirus RNA and adenovirus DNA) by (RT)-nested polymerase chain reaction. Faecal indicator bacteria concentrations were generally higher nearshore and in the coral SML. Enteric viruses were evenly distributed across the transect stations. Adenoviruses were detected in 37 of 75 samples collected (49.3%) whereas enteroviruses were only found in 8 of 75 samples (10.7%). Both viruses were detected twice as frequently in coral compared with surface water or groundwater. Offshore, viruses were most likely to be found in groundwater, especially during the wet summer season. These data suggest that polluted groundwater may be moving to the outer reef environment in the Florida Keys.

  8. Moving environmental DNA methods from concept to practice for monitoring aquatic macroorganisms

    USGS Publications Warehouse

    Goldberg, Caren S.; Strickler, Katherine M.; Pilliod, David S.

    2015-01-01

    The discovery that macroorganisms can be detected from their environmental DNA (eDNA) in aquatic systems has immense potential for the conservation of biological diversity. This special issue contains 11 papers that review and advance the field of eDNA detection of vertebrates and other macroorganisms, including studies of eDNA production, transport, and degradation; sample collection and processing to maximize detection rates; and applications of eDNA for conservation using citizen scientists. This body of work is an important contribution to the ongoing efforts to take eDNA detection of macroorganisms from technical breakthrough to established, reliable method that can be used in survey, monitoring, and research applications worldwide. While the rapid advances in this field are remarkable, important challenges remain, including consensus on best practices for collection and analysis, understanding of eDNA diffusion and transport, and avoidance of inhibition in sample collection and processing. Nonetheless, as demonstrated in this special issue, eDNA techniques for research and monitoring are beginning to realize their potential for contributing to the conservation of biodiversity globally.

  9. Biobanking trends, challenges, and opportunities.

    PubMed

    Mackenzie, Fiona

    2014-01-01

    To review the different interests and needs of industry and academic users of human biomaterials. A review of the current literature and interviews with involved parties. Questionnaires were e-mailed to assess current attitudes towards biobanking and opinions of trends and implications for the future. The organisations included commercial biobanks, charitable foundations, academic biobanks, and hospital sites. Biobanks have the potential to have a critical impact across several industrial sectors, and their future success will depend on satisfying the differing needs of each group. There is a growing need for greater collaboration between researchers and biobanks, and if the involvement of industry is not sought by biobanks to create conditions that support the effective use of resources, there is a risk that samples will not be collected or used to the best advantage. It is evident that industry can play a vital role in the innovation process of biobanking, both in terms of the collecting and processing methods and the nature of the disease and sample types collected. With this feedback, biobanks can be utilised effectively to advance research to the benefits of all to the best advantage.

  10. Impact of temperature and time storage on the microbial detection of oral samples by Checkerboard DNA-DNA hybridization method.

    PubMed

    do Nascimento, Cássio; dos Santos, Janine Navarro; Pedrazzi, Vinícius; Pita, Murillo Sucena; Monesi, Nadia; Ribeiro, Ricardo Faria; de Albuquerque, Rubens Ferreira

    2014-01-01

    Molecular diagnosis methods have been largely used in epidemiological or clinical studies to detect and quantify microbial species that may colonize the oral cavity in healthy or disease. The preservation of genetic material from samples remains the major challenge to ensure the feasibility of these methodologies. Long-term storage may compromise the final result. The aim of this study was to evaluate the effect of temperature and time storage on the microbial detection of oral samples by Checkerboard DNA-DNA hybridization. Saliva and supragingival biofilm were taken from 10 healthy subjects, aliquoted (n=364) and processed according to proposed protocols: immediate processing and processed after 2 or 4 weeks, and 6 or 12 months of storage at 4°C, -20°C and -80°C. Either total or individual microbial counts were recorded in lower values for samples processed after 12 months of storage, irrespective of temperatures tested. Samples stored up to 6 months at cold temperatures showed similar counts to those immediately processed. The microbial incidence was also significantly reduced in samples stored during 12 months in all temperatures. Temperature and time of oral samples storage have relevant impact in the detection and quantification of bacterial and fungal species by Checkerboard DNA-DNA hybridization method. Samples should be processed immediately after collection or up to 6 months if conserved at cold temperatures to avoid false-negative results. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Evaluation of the BD Vacutainer Plus Urine C&S Preservative Tubes compared with nonpreservative urine samples stored at 4°C and room temperature.

    PubMed

    Eisinger, Stephen W; Schwartz, Matthew; Dam, Lisa; Riedel, Stefan

    2013-09-01

    The stability of urine specimens submitted for culture remains a challenge for many laboratories because of delays in specimen transport. We evaluated the usefulness of BD Vacutainer Plus Urine C&S Preservative Tube in ensuring specimen stability. Clinical urine specimens collected in sterile collection cups (n = 110) were plated onto sheep blood and MacConkey agar following standard laboratory procedures guidelines. Thereafter, specimens were divided into 3 storage conditions: nonpreservative, refrigerated; nonpreservative, room temperature (RT); BD Vacutainer Plus Urine C&S Preservative Tube, RT. For each sample type, additional cultures were set up at 2, 4, 24, and 48 hours. Initially, 18 specimens had no growth, 32 showed mixed skin flora, and 60 yielded at least 1 uropathogen. Increased colony counts of uropathogens were observed for nonpreserved urine samples stored at RT; these changes were statistically significant. Minor differences between refrigerated urine samples and BD Vacutainer Plus Urine C&S Preservative Tube samples were seen but were not statistically significant. The use of preservative-containing collection tubes is desirable to ensure specimen stability when prompt processing or refrigeration is not feasible.

  12. Human-health pharmaceutical compounds in Lake Mead, Nevada and Arizona, and Las Vegas Wash, Nevada, October 2000-August 2001

    USGS Publications Warehouse

    Boyd, Robert A.; Furlong, Edward T.

    2002-01-01

    The U.S. Geological Survey and the National Park Service conducted a reconnaissance study to investigate the occurrence of selected human-health pharmaceutical compounds in water samples collected from Lake Mead on the Colorado River and Las Vegas Wash, a waterway used to transport treated wastewater from the Las Vegas metropolitan area to Lake Mead. Current research indicates many of these compounds can bioaccumulate and may adversely affect aquatic organisms by disrupting physiological processes, impairing reproductive functions, increasing cancer rates, contributing to the development of antibiotic-resistant strains of bacteria, and acting in undesirable ways when mixed with other substances. These compounds may be present in effluent because a high percentage of prescription and non-prescription drugs used for human-health purposes are excreted from the body as a mixture of parent compounds and degraded metabolite compounds; also, they can be released to the environment when unused products are discarded by way of toilets, sinks, and trash in landfills. Thirteen of 33 targeted compounds were detected in at least one water sample collected between October 2000 and August 2001. All concentrations were less than or equal to 0.20 micrograms per liter. The most frequently detected compounds in samples from Las Vegas Wash were caffeine, carbamazepine (used to treat epilepsy), cotinine (a metabolite of nicotine), and dehydronifedipine (a metabolite of the antianginal Procardia). Less frequently detected compounds in samples collected from Las Vegas Wash were antibiotics (clarithromycin, erythromycin, sulfamethoxazole, and trimethoprim), acetaminophen (an analgesic and anti-inflammatory), cimetidine (used to treat ulcers), codeine (a narcotic and analgesic), diltiazem (an antihypertensive), and 1,7-dimethylxanthine (a metabolite of caffeine). Fewer compounds were detected in samples collected from Lake Mead than from Las Vegas Wash. Caffeine was detected in all samples collected from Lake Mead. Other compounds detected in samples collected from Lake Mead were acetaminophen, carbamazepine, cotinine, 1,7-dimethylxanthine, and sulfamethoxazole.

  13. Mesh-size effects on drift sample composition as determined with a triple net sampler

    USGS Publications Warehouse

    Slack, K.V.; Tilley, L.J.; Kennelly, S.S.

    1991-01-01

    Nested nets of three different mesh apertures were used to study mesh-size effects on drift collected in a small mountain stream. The innermost, middle, and outermost nets had, respectively, 425 ??m, 209 ??m and 106 ??m openings, a design that reduced clogging while partitioning collections into three size groups. The open area of mesh in each net, from largest to smallest mesh opening, was 3.7, 5.7 and 8.0 times the area of the net mouth. Volumes of filtered water were determined with a flowmeter. The results are expressed as (1) drift retained by each net, (2) drift that would have been collected by a single net of given mesh size, and (3) the percentage of total drift (the sum of the catches from all three nets) that passed through the 425 ??m and 209 ??m nets. During a two day period in August 1986, Chironomidae larvae were dominant numerically in all 209 ??m and 106 ??m samples and midday 425 ??m samples. Large drifters (Ephemerellidae) occurred only in 425 ??m or 209 ??m nets, but the general pattern was an increase in abundance and number of taxa with decreasing mesh size. Relatively more individuals occurred in the larger mesh nets at night than during the day. The two larger mesh sizes retained 70% of the total sediment/detritus in the drift collections, and this decreased the rate of clogging of the 106 ??m net. If an objective of a sampling program is to compare drift density or drift rate between areas or sampling dates, the same mesh size should be used for all sample collection and processing. The mesh aperture used for drift collection should retain all species and life stages of significance in a study. The nested net design enables an investigator to test the adequacy of drift samples. ?? 1991 Kluwer Academic Publishers.

  14. Estrogen and androgen receptor activities of hydraulic fracturing chemicals and surface and ground water in a drilling-dense region

    USGS Publications Warehouse

    Kassotis, Christopher D.; Tillitt, Donald E.; Davis, J. Wade; Hormann, Anette M.; Nagel, Susan C.

    2014-01-01

    The rapid rise in natural gas extraction using hydraulic fracturing increases the potential for contamination of surface and ground water from chemicals used throughout the process. Hundreds of products containing more than 750 chemicals and components are potentially used throughout the extraction process, including more than 100 known or suspected endocrine-disrupting chemicals. We hypothesized thataselected subset of chemicalsusedin natural gas drilling operationsandalso surface and ground water samples collected in a drilling-dense region of Garfield County, Colorado, would exhibit estrogen and androgen receptor activities. Water samples were collected, solid-phase extracted, and measured for estrogen and androgen receptor activities using reporter gene assays in human cell lines. Of the 39 unique water samples, 89%, 41%, 12%, and 46% exhibited estrogenic, antiestrogenic, androgenic, and antiandrogenic activities, respectively. Testing of a subset of natural gas drilling chemicals revealed novel antiestrogenic, novel antiandrogenic, and limited estrogenic activities. The Colorado River, the drainage basin for this region, exhibited moderate levels of estrogenic, antiestrogenic, and antiandrogenic activities, suggesting that higher localized activity at sites with known natural gas–related spills surrounding the river might be contributing to the multiple receptor activities observed in this water source. The majority of water samples collected from sites in a drilling-dense region of Colorado exhibited more estrogenic, antiestrogenic, or antiandrogenic activities than reference sites with limited nearby drilling operations. Our data suggest that natural gas drilling operationsmayresult in elevated endocrine-disrupting chemical activity in surface and ground water.

  15. 40 CFR 61.242-5 - Standards: Sampling connecting systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Collect and recycle the purged process fluid; or (3) Be designed and operated to capture and transport all the purged process fluid to a control device that complies with the requirements of § 61.242-11; or (4... operated in compliance with the provisions of 40 CFR part 63, subpart G, applicable to Group 1 wastewater...

  16. 40 CFR 61.242-5 - Standards: Sampling connecting systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Collect and recycle the purged process fluid; or (3) Be designed and operated to capture and transport all the purged process fluid to a control device that complies with the requirements of § 61.242-11; or (4... operated in compliance with the provisions of 40 CFR part 63, subpart G, applicable to Group 1 wastewater...

  17. Mathematics and Science Teachers' Perceptions about Using Drama during the Digital Story Creation Process

    ERIC Educational Resources Information Center

    Yuksekyalcin, Gozen; Tanriseven, Isil; Sancar-Tokmak, Hatice

    2016-01-01

    This case study investigated math and science teachers' perceptions about the use of creative drama during a digital story (DS) creation process for educational purposes. A total of 25 secondary science and math teachers were selected according to criterion sampling strategy to participate in the study. Data were collected through an open-ended…

  18. Incidence of Listeria spp. in Ready-to-Eat Food Processing Plant Environments Regulated by the U.S. Food Safety and Inspection Service and the U.S. Food and Drug Administration.

    PubMed

    Reinhard, Robert G; Kalinowski, Robin M; Bodnaruk, Peter W; Eifert, Joseph D; Boyer, Renee R; Duncan, Susan E; Bailey, R Hartford

    2018-06-07

    A multiyear survey of 31 ready-to-eat (RTE) food processing plants in the United States was conducted to determine the incidence of Listeria spp. in various RTE production environments. Samples were collected from 22 RTE plants regulated by the U.S. Department of Agriculture's Food Safety and Inspection Service (FSIS) and from 9 RTE food plants regulated by the U.S. Department of Health and Human Services' Food and Drug Administration (FDA). Only nonfood contact surfaces in the RTE manufacturing areas with exposed RTE product were sampled. Each sample was individually analyzed for the presence of Listeria spp. by using a PCR-based rapid assay. In total, 4,829 samples were collected from various locations, including freezers, equipment framework, floors, walls, wall-floor junctures, drains, floor mats, doors, and cleaning tools. Nine (29%) of the facilities had zero samples positive for Listeria spp. in the production environment, whereas 22 (71%) had one or more samples positive for Listeria spp. The total incidence of Listeria spp. in all RTE food plants was 4.5%. The positive rate in plants regulated by the FSIS ranged from 0 to 9.7%, whereas the positive rate in plants regulated by the FDA ranged from 1.2 to 36%.

  19. The impact of fecal sample processing on prevalence estimates for antibiotic-resistant Escherichia coli.

    PubMed

    Omulo, Sylvia; Lofgren, Eric T; Mugoh, Maina; Alando, Moshe; Obiya, Joshua; Kipyegon, Korir; Kikwai, Gilbert; Gumbi, Wilson; Kariuki, Samuel; Call, Douglas R

    2017-05-01

    Investigators often rely on studies of Escherichia coli to characterize the burden of antibiotic resistance in a clinical or community setting. To determine if prevalence estimates for antibiotic resistance are sensitive to sample handling and interpretive criteria, we collected presumptive E. coli isolates (24 or 95 per stool sample) from a community in an urban informal settlement in Kenya. Isolates were tested for susceptibility to nine antibiotics using agar breakpoint assays and results were analyzed using generalized linear mixed models. We observed a <3-fold difference between prevalence estimates based on freshly isolated bacteria when compared to isolates collected from unprocessed fecal samples or fecal slurries that had been stored at 4°C for up to 7days. No time-dependence was evident (P>0.1). Prevalence estimates did not differ for five distinct E. coli colony morphologies on MacConkey agar plates (P>0.2). Successive re-plating of samples for up to five consecutive days had little to no impact on prevalence estimates. Finally, culturing E. coli under different conditions (with 5% CO 2 or micro-aerobic) did not affect estimates of prevalence. For the conditions tested in these experiments, minor modifications in sample processing protocols are unlikely to bias estimates of the prevalence of antibiotic-resistance for fecal E. coli. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Novel Diffusion-Weighted MRI for High-Grade Prostate Cancer Detection

    DTIC Science & Technology

    2016-10-01

    in image resolution and scale.This process is critical for evaluating new imaging modalities.Our initial findings illustrate the potential of the...eligible for analysis as determined by adequate pathologic processing and MR images deemed to be of adequate quality by the study team.  The...histology samples have been requested from the UIC biorepository for digitization  All MR images have been collected and prepared for image processing

  1. Elemental analysis of size-fractionated particulate matter sampled in Göteborg, Sweden

    NASA Astrophysics Data System (ADS)

    Wagner, Annemarie; Boman, Johan; Gatari, Michael J.

    2008-12-01

    The aim of the study was to investigate the mass distribution of trace elements in aerosol samples collected in the urban area of Göteborg, Sweden, with special focus on the impact of different air masses and anthropogenic activities. Three measurement campaigns were conducted during December 2006 and January 2007. A PIXE cascade impactor was used to collect particulate matter in 9 size fractions ranging from 16 to 0.06 µm aerodynamic diameter. Polished quartz carriers were chosen as collection substrates for the subsequent direct analysis by TXRF. To investigate the sources of the analyzed air masses, backward trajectories were calculated. Our results showed that diurnal sampling was sufficient to investigate the mass distribution for Br, Ca, Cl, Cu, Fe, K, Sr and Zn, whereas a 5-day sampling period resulted in additional information on mass distribution for Cr and S. Unimodal mass distributions were found in the study area for the elements Ca, Cl, Fe and Zn, whereas the distributions for Br, Cu, Cr, K, Ni and S were bimodal, indicating high temperature processes as source of the submicron particle components. The measurement period including the New Year firework activities showed both an extensive increase in concentrations as well as a shift to the submicron range for K and Sr, elements that are typically found in fireworks. Further research is required to validate the quantification of trace elements directly collected on sample carriers.

  2. Mycobiota of cocoa: from farm to chocolate.

    PubMed

    Copetti, Marina V; Iamanaka, Beatriz T; Frisvad, Jens C; Pereira, José L; Taniwaki, Marta H

    2011-12-01

    The present work was carried out to study the mycobiota of cocoa beans from farm to chocolate. Four hundred and ninety-four samples were analyzed at various stages of cocoa processing: (i) primary stage at the farm (fermentation, drying, and storage), (ii) secondary stage at processing (testa, nibs, liquor, butter, cake and powder) and (iii) the final chocolate product (dark, milk, white and powdered) collected from retail outlets. Direct plating or dilution plating on Dichloran 18% Glycerol agar were used for cocoa beans and processed product analyses, respectively. Fungi were isolated and identified using different keys of identification. The largest numbers and diversity of fungi were observed in the samples collected at the farm, especially during drying and storage. The species with the highest occurrence among samples were: Absidia corymbifera, Aspergillus sp. nov., A. flavus, Penicillium paneum and yeasts. A total of 1132 potentially toxigenic fungi were isolated from the following species or species groups: A. flavus, Aspergillus parasiticus, Aspergillus nomius, Aspergillus niger group, Aspergillus carbonarius and Aspergillus ochraceus group. The highest percentage of toxigenic fungi was found at the drying and storage stages. The industrial processing reduced the fungal contamination in all fractions and no fungi were found in the final chocolate products. The knowledge of which fungi are dominant at each processing stage of cocoa provides important data about their ecology. This understanding leads to a reduction in fungal spoilage and mycotoxin production in this product. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Is it really theoretical? A review of sampling in grounded theory studies in nursing journals.

    PubMed

    McCrae, Niall; Purssell, Edward

    2016-10-01

    Grounded theory is a distinct method of qualitative research, where core features are theoretical sampling and constant comparative analysis. However, inconsistent application of these activities has been observed in published studies. This review assessed the use of theoretical sampling in grounded theory studies in nursing journals. An adapted systematic review was conducted. Three leading nursing journals (2010-2014) were searched for studies stating grounded theory as the method. Sampling was assessed using a concise rating tool. A high proportion (86%) of the 134 articles described an iterative process of data collection and analysis. However, half of the studies did not demonstrate theoretical sampling, with many studies declaring or indicating a purposive sampling approach throughout. Specific reporting guidelines for grounded theory studies should be developed to ensure that study reports describe an iterative process of fieldwork and theoretical development. © 2016 John Wiley & Sons Ltd.

  4. Evaluation of sampling and storage procedures on preserving the community structure of stool microbiota: A simple at-home toilet-paper collection method.

    PubMed

    Al, Kait F; Bisanz, Jordan E; Gloor, Gregory B; Reid, Gregor; Burton, Jeremy P

    2018-01-01

    The increasing interest on the impact of the gut microbiota on health and disease has resulted in multiple human microbiome-related studies emerging. However, multiple sampling methods are being used, making cross-comparison of results difficult. To avoid additional clinic visits and increase patient recruitment to these studies, there is the potential to utilize at-home stool sampling. The aim of this pilot study was to compare simple self-sampling collection and storage methods. To simulate storage conditions, stool samples from three volunteers were freshly collected, placed on toilet tissue, and stored at four temperatures (-80, 7, 22 and 37°C), either dry or in the presence of a stabilization agent (RNAlater®) for 3 or 7days. Using 16S rRNA gene sequencing by Illumina, the effect of storage variations for each sample was compared to a reference community from fresh, unstored counterparts. Fastq files may be accessed in the NCBI Sequence Read Archive: Bioproject ID PRJNA418287. Microbial diversity and composition were not significantly altered by any storage method. Samples were always separable based on participant, regardless of storage method suggesting there was no need for sample preservation by a stabilization agent. In summary, if immediate sample processing is not feasible, short term storage of unpreserved stool samples on toilet paper offers a reliable way to assess the microbiota composition by 16S rRNA gene sequencing. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Supercritical Fluid Extraction and Analysis of Tropospheric Aerosol Particles

    NASA Astrophysics Data System (ADS)

    Hansen, Kristen J.

    An integrated sampling and supercritical fluid extraction (SFE) cell has been designed for whole-sample analysis of organic compounds on tropospheric aerosol particles. The low-volume extraction cell has been interfaced with a sampling manifold for aerosol particle collection in the field. After sample collection, the entire SFE cell was coupled to a gas chromatograph; after on-line extraction, the cryogenically -focused sample was separated and the volatile compounds detected with either a mass spectrometer or a flame ionization detector. A 20-minute extraction at 450 atm and 90 ^circC with pure supercritical CO _2 is sufficient for quantitative extraction of most volatile compounds in aerosol particle samples. A comparison between SFE and thermal desorption, the traditional whole-sample technique for analyses of this type, was performed using ambient aerosol particle samples, as well as samples containing known amounts of standard analytes. The results of these studies indicate that SFE of atmospheric aerosol particles provides quantitative measurement of several classes of organic compounds. SFE provides information that is complementary to that gained by the thermal desorption analysis. The results also indicate that SFE with CO _2 can be validated as an alternative to thermal desorption for quantitative recovery of several organic compounds. In 1989, the organic constituents of atmospheric aerosol particles collected at Niwot Ridge, Colorado, along with various physical and meteorological data, were measured during a collaborative field study. Temporal changes in the composition of samples collected during summertime at the rural site were studied. Thermal desorption-GC/FID was used to quantify selected compounds in samples collected during the field study. The statistical analysis of the 1989 Niwot Ridge data set is presented in this work. Principal component analysis was performed on thirty-one variables selected from the data set in order to ascertain different source and process components, and to examine concentration changes in groups of variables with respect to time of day and meteorological conditions. Seven orthogonal groups of variables resulted from the statistical analysis; the groups serve as molecular markers for different biologic and anthropogenic emission sources. In addition, the results of the statistical analysis were used to investigate how several emission source contributions vary with respect to local atmospheric dynamics. Field studies were conducted in the urban environment in and around Boulder, CO. to characterize the dynamics, chemistry, and emission sources which affect the composition and concentration of different size-fractions of aerosol particles in the Boulder air mass. Relationships between different size fractions of particles and some gas-phase pollutants were elucidated. These field studies included an investigation of seasonal variations in the organic content and concentration of aerosol particles, and how these characteristics are related to local meteorology and to the concentration of some gas-phase pollutants. The elemental and organic composition of aerosol particles was investigated according to particle size in preliminary studies of size-differentiated samples of aerosol particles. In order to aid in future studies of urban aerosol particles, samples were collected at a forest fire near Boulder. Molecular markers specific to wood burning processes will be useful indicators of residential wood burning activities in future field studies.

  6. Parallel detecting, spectroscopic ellipsometers/polarimeters

    DOEpatents

    Furtak, Thomas E.

    2002-01-01

    The parallel detecting spectroscopic ellipsometer/polarimeter sensor has no moving parts and operates in real-time for in-situ monitoring of the thin film surface properties of a sample within a processing chamber. It includes a multi-spectral source of radiation for producing a collimated beam of radiation directed towards the surface of the sample through a polarizer. The thus polarized collimated beam of radiation impacts and is reflected from the surface of the sample, thereby changing its polarization state due to the intrinsic material properties of the sample. The light reflected from the sample is separated into four separate polarized filtered beams, each having individual spectral intensities. Data about said four individual spectral intensities is collected within the processing chamber, and is transmitted into one or more spectrometers. The data of all four individual spectral intensities is then analyzed using transformation algorithms, in real-time.

  7. Synthetic aperture radar and digital processing: An introduction

    NASA Technical Reports Server (NTRS)

    Dicenzo, A.

    1981-01-01

    A tutorial on synthetic aperture radar (SAR) is presented with emphasis on digital data collection and processing. Background information on waveform frequency and phase notation, mixing, Q conversion, sampling and cross correlation operations is included for clarity. The fate of a SAR signal from transmission to processed image is traced in detail, using the model of a single bright point target against a dark background. Some of the principal problems connected with SAR processing are also discussed.

  8. BIOMONITORING OF EXPOSURE IN FARMWORKER STUDIES

    EPA Science Inventory

    Though biomonitoring has been used in many occupational and environmental health and exposure studies, we are only beginning to understand the complexities and uncertainties involved with the biomonitoring process -- from study design, to sample collection, to chemical analysis -...

  9. Changes to Serum Sample Tube and Processing Methodology Does Not Cause Inter-Individual Variation in Automated Whole Serum N-Glycan Profiling in Health and Disease

    PubMed Central

    Shubhakar, Archana; Kalla, Rahul; Nimmo, Elaine R.; Fernandes, Daryl L.; Satsangi, Jack; Spencer, Daniel I. R.

    2015-01-01

    Introduction Serum N-glycans have been identified as putative biomarkers for numerous diseases. The impact of different serum sample tubes and processing methods on N-glycan analysis has received relatively little attention. This study aimed to determine the effect of different sample tubes and processing methods on the whole serum N-glycan profile in both health and disease. A secondary objective was to describe a robot automated N-glycan release, labeling and cleanup process for use in a biomarker discovery system. Methods 25 patients with active and quiescent inflammatory bowel disease and controls had three different serum sample tubes taken at the same draw. Two different processing methods were used for three types of tube (with and without gel-separation medium). Samples were randomised and processed in a blinded fashion. Whole serum N-glycan release, 2-aminobenzamide labeling and cleanup was automated using a Hamilton Microlab STARlet Liquid Handling robot. Samples were analysed using a hydrophilic interaction liquid chromatography/ethylene bridged hybrid(BEH) column on an ultra-high performance liquid chromatography instrument. Data were analysed quantitatively by pairwise correlation and hierarchical clustering using the area under each chromatogram peak. Qualitatively, a blinded assessor attempted to match chromatograms to each individual. Results There was small intra-individual variation in serum N-glycan profiles from samples collected using different sample processing methods. Intra-individual correlation coefficients were between 0.99 and 1. Unsupervised hierarchical clustering and principal coordinate analyses accurately matched samples from the same individual. Qualitative analysis demonstrated good chromatogram overlay and a blinded assessor was able to accurately match individuals based on chromatogram profile, regardless of disease status. Conclusions The three different serum sample tubes processed using the described methods cause minimal inter-individual variation in serum whole N-glycan profile when processed using an automated workstream. This has important implications for N-glycan biomarker discovery studies using different serum processing standard operating procedures. PMID:25831126

  10. Changes to serum sample tube and processing methodology does not cause Intra-Individual [corrected] variation in automated whole serum N-glycan profiling in health and disease.

    PubMed

    Ventham, Nicholas T; Gardner, Richard A; Kennedy, Nicholas A; Shubhakar, Archana; Kalla, Rahul; Nimmo, Elaine R; Fernandes, Daryl L; Satsangi, Jack; Spencer, Daniel I R

    2015-01-01

    Serum N-glycans have been identified as putative biomarkers for numerous diseases. The impact of different serum sample tubes and processing methods on N-glycan analysis has received relatively little attention. This study aimed to determine the effect of different sample tubes and processing methods on the whole serum N-glycan profile in both health and disease. A secondary objective was to describe a robot automated N-glycan release, labeling and cleanup process for use in a biomarker discovery system. 25 patients with active and quiescent inflammatory bowel disease and controls had three different serum sample tubes taken at the same draw. Two different processing methods were used for three types of tube (with and without gel-separation medium). Samples were randomised and processed in a blinded fashion. Whole serum N-glycan release, 2-aminobenzamide labeling and cleanup was automated using a Hamilton Microlab STARlet Liquid Handling robot. Samples were analysed using a hydrophilic interaction liquid chromatography/ethylene bridged hybrid(BEH) column on an ultra-high performance liquid chromatography instrument. Data were analysed quantitatively by pairwise correlation and hierarchical clustering using the area under each chromatogram peak. Qualitatively, a blinded assessor attempted to match chromatograms to each individual. There was small intra-individual variation in serum N-glycan profiles from samples collected using different sample processing methods. Intra-individual correlation coefficients were between 0.99 and 1. Unsupervised hierarchical clustering and principal coordinate analyses accurately matched samples from the same individual. Qualitative analysis demonstrated good chromatogram overlay and a blinded assessor was able to accurately match individuals based on chromatogram profile, regardless of disease status. The three different serum sample tubes processed using the described methods cause minimal inter-individual variation in serum whole N-glycan profile when processed using an automated workstream. This has important implications for N-glycan biomarker discovery studies using different serum processing standard operating procedures.

  11. Hydrological, water-quality, and ecological data for streams in Independence, Missouri, June 2005 through September 2013

    USGS Publications Warehouse

    Niesen, Shelley L.; Christensen, Eric D.

    2015-01-01

    Water-quality, hydrological, and ecological data collected from June 2005 through September 2013 from the Little Blue River and smaller streams within the City of Independence, Missouri, are presented in this report. These data were collected as a part of an ongoing cooperative study between the U.S. Geological Survey and the City of Independence Water Pollution Control Department to characterize the water quality and ecological condition of Independence streams. The quantities, sources of selected constituents, and processes affecting water quality and aquatic life were evaluated to determine the resulting ecological condition of streams within Independence. Data collected for this study fulfill the municipal separate sewer system permit requirements for the City of Independence and can be used to provide a baseline with which city managers can determine the effectiveness of current (2014) and future best management practices within Independence. Continuous streamflow and water-quality data, collected during base flow and stormflow, included physical and chemical properties, inorganic constituents, common organic micro-constituents, pesticides in streambed sediment and surface water, fecal indicator bacteria and microbial source tracking data, and suspended sediment. Dissolved oxygen, pH, specific conductance, water temperature, and turbidity data were measured continuously at seven sites within Independence. Base-flow and stormflow samples were collected at eight gaged and two ungaged sites. Fecal sources samples were collected for reference for microbial source tracking, and sewage influent samples were collected as additional source samples. Dry-weather screening was done on 11 basins within Independence to identify potential contaminant sources to the streams. Benthic macroinvertebrate community surveys and habitat assessments were done on 10 stream sites and 2 comparison sites outside the city. Sampling and laboratory procedures and quality-assurance and quality-control methods used in data collection for this study are described in this report.

  12. The STRATAFORM Project: U.S. Geological Survey geotechnical studies

    USGS Publications Warehouse

    Minasian, Diane L.; Lee, Homa J.; Locat, Jaques; Orzech, Kevin M.; Martz, Gregory R.; Israel, Kenneth

    2001-01-01

    This report presents physical property logs of core samples from an offshore area near Eureka, CA. The cores were obtained as part of the STRATAFORM Program (Nittrouer and Kravitz, 1995, 1996), a study investigating how present sedimentation and sediment transport processes influence long-term stratigraphic sequences preserved in the geologic record. The core samples were collected during four separate research cruises to the northern California study area, and data shown in the logs of the cores were collected using a multi-sensor whole core logger. The physical properties collected are useful in identifying stratigraphic units, ground-truthing acoustic imagery and sub-bottom profiles, and in understanding mass movement processes. STRATA FORmation on Margins was initiated in 1994 by the Office of Naval Research, Marine Geology and Geophysics Department as a coordinated multi-investigator study of continental-margin sediment transport processes and stratigraphy (Nittrouer and Kravitz, 1996). The program is investigating the stratigraphic signature of the shelf and slope parts of the continental margins, and is designed to provide a better understanding of the sedimentary record and a better prediction of strata. Specifically, the goals of the STRATAFORM Program are to (Nittrouer and Kravitz, 1995): - determine the geological relevance of short-term physical processes that erode, transport, and deposit particles and those processes that subsequently rework the seabed over time scales - improve capabilities for identifying the processes that form the strata observed within the upper ~100 m of the seabed commonly representing 104-106 years of sedimentation. - synthesize this knowledge and bridge the gap between time scales of sedimentary processes and those of sequence stratigraphy. The STRATAFORM Program is divided into studies of the continental shelf and the continental slope; the geotechnical group within the U.S. Geological Survey provides support to both parts of the project.

  13. Evaluation of FTA cards as a laboratory and field sampling device for the detection of foot-and-mouth disease virus and serotyping by RT-PCR and real-time RT-PCR.

    PubMed

    Muthukrishnan, Madhanmohan; Singanallur, Nagendrakumar B; Ralla, Kumar; Villuppanoor, Srinivasan A

    2008-08-01

    Foot-and-mouth disease virus (FMDV) samples transported to the laboratory from far and inaccessible areas for serodiagnosis pose a major problem in a tropical country like India, where there is maximum temperature fluctuation. Inadequate storage methods lead to spoilage of FMDV samples collected from clinically positive animals in the field. Such samples are declared as non-typeable by the typing laboratories with the consequent loss of valuable epidemiological data. The present study evaluated the usefulness of FTA Classic Cards for the collection, shipment, storage and identification of the FMDV genome by RT-PCR and real-time RT-PCR. The stability of the viral RNA, the absence of infectivity and ease of processing the sample for molecular methods make the FTA cards a useful option for transport of FMDV genome for identification and serotyping. The method can be used routinely for FMDV research as it is economical and the cards can be transported easily in envelopes by regular document transport methods. Live virus cannot be isolated from samples collected in FTA cards, which is a limitation. This property can be viewed as an advantage as it limits the risk of transmission of live virus.

  14. Bed-Sediment Sampling and Analysis for Physical and Chemical Properties of the Lower Mississippi River near Memphis, Tennessee

    USGS Publications Warehouse

    Blanchard, Robert A.; Wagner, Daniel M.; Evans, Dennis A.

    2010-01-01

    In February 2010, the U.S. Geological Survey, in cooperation with the U.S. Army Corps of Engineers, Memphis District, investigated the presence of inorganic elements and organic compounds in bed sediments of the lower Mississippi River. Selected sites were located in the navigation channel near river miles 737, 773, and 790 near Memphis, Tennessee. Bed-sediment samples were collected using a Shipek grab sampler mounted to a boom crane with a motorized winch. Samples then were processed and shipped to the U.S. Geological Survey Sediment Laboratory in Rolla, Missouri, the USGS National Water Quality Laboratory in Denver, Colorado, and to TestAmerica Laboratory, Inc. in West Sacramento, California. Samples were analyzed for grain size, inorganic elements (including mercury), and organic compounds. Chemical results were tabulated and listed with sediment-quality guidelines and presented with the physical property results. All of the bed material samples collected during this investigation yielded concentrations that were less than the Consensus-Based Probable Effect Concentration guidelines. The physical properties were tabulated and listed using a standard U.S. Geological Survey scale of sizes by class for sediment analysis. All of the samples collected during this investigation indicated a percent composition mostly comprised of sand, ranging from less than 0.125 millimeters to less than 2 millimeters.

  15. Advances in Small Particle Handling of Astromaterials in Preparation for OSIRIS-REx and Hayabusa2: Initial Developments

    NASA Technical Reports Server (NTRS)

    Snead, C. J.; McCubbin, F. M.; Nakamura-Messenger, K.; Righter, K.

    2018-01-01

    The Astromaterials Acquisition and Curation office at NASA Johnson Space Center has established an Advanced Curation program that is tasked with developing procedures, technologies, and data sets necessary for the curation of future astromaterials collections as envisioned by NASA exploration goals. One particular objective of the Advanced Curation program is the development of new methods for the collection, storage, handling and characterization of small (less than 100 micrometer) particles. Astromaterials Curation currently maintains four small particle collections: Cosmic Dust that has been collected in Earth's stratosphere by ER2 and WB-57 aircraft, Comet 81P/Wild 2 dust returned by NASA's Stardust spacecraft, interstellar dust that was returned by Stardust, and asteroid Itokawa particles that were returned by the JAXA's Hayabusa spacecraft. NASA Curation is currently preparing for the anticipated return of two new astromaterials collections - asteroid Ryugu regolith to be collected by Hayabusa2 spacecraft in 2021 (samples will be provided by JAXA as part of an international agreement), and asteroid Bennu regolith to be collected by the OSIRIS-REx spacecraft and returned in 2023. A substantial portion of these returned samples are expected to consist of small particle components, and mission requirements necessitate the development of new processing tools and methods in order to maximize the scientific yield from these valuable acquisitions. Here we describe initial progress towards the development of applicable sample handling methods for the successful curation of future small particle collections.

  16. X-Ray Computed Tomography: The First Step in Mars Sample Return Processing

    NASA Technical Reports Server (NTRS)

    Welzenbach, L. C.; Fries, M. D.; Grady, M. M.; Greenwood, R. C.; McCubbin, F. M.; Zeigler, R. A.; Smith, C. L.; Steele, A.

    2017-01-01

    The Mars 2020 rover mission will collect and cache samples from the martian surface for possible retrieval and subsequent return to Earth. If the samples are returned, that mission would likely present an opportunity to analyze returned Mars samples within a geologic context on Mars. In addition, it may provide definitive information about the existence of past or present life on Mars. Mars sample return presents unique challenges for the collection, containment, transport, curation and processing of samples [1] Foremost in the processing of returned samples are the closely paired considerations of life detection and Planetary Protection. In order to achieve Mars Sample Return (MSR) science goals, reliable analyses will depend on overcoming some challenging signal/noise-related issues where sparse martian organic compounds must be reliably analyzed against the contamination background. While reliable analyses will depend on initial clean acquisition and robust documentation of all aspects of developing and managing the cache [2], there needs to be a reliable sample handling and analysis procedure that accounts for a variety of materials which may or may not contain evidence of past or present martian life. A recent report [3] suggests that a defined set of measurements should be made to effectively inform both science and Planetary Protection, when applied in the context of the two competing null hypotheses: 1) that there is no detectable life in the samples; or 2) that there is martian life in the samples. The defined measurements would include a phased approach that would be accepted by the community to preserve the bulk of the material, but provide unambiguous science data that can be used and interpreted by various disciplines. Fore-most is the concern that the initial steps would ensure the pristine nature of the samples. Preliminary, non-invasive techniques such as computed X-ray tomography (XCT) have been suggested as the first method to interrogate and characterize the cached samples without altering the materials [1,2]. A recent report [4] indicates that XCT may minimally alter samples for some techniques, and work is needed to quantify these effects, maximizing science return from XCT initial analysis while minimizing effects.

  17. Introduction to the Apollo collections: Part 2: Lunar breccias

    NASA Technical Reports Server (NTRS)

    Mcgee, P. E.; Simonds, C. H.; Warner, J. L.; Phinney, W. C.

    1979-01-01

    Basic petrographic, chemical and age data for a representative suite of lunar breccias are presented for students and potential lunar sample investigators. Emphasis is on sample description and data presentation. Samples are listed, together with a classification scheme based on matrix texture and mineralogy and the nature and abundance of glass present both in the matrix and as clasts. A calculus of the classification scheme, describes the characteristic features of each of the breccia groups. The cratering process which describes the sequence of events immediately following an impact event is discussed, especially the thermal and material transport processes affecting the two major components of lunar breccias (clastic debris and fused material).

  18. Process Analyzer

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The ChemScan UV-6100 is a spectrometry system originally developed by Biotronics Technologies, Inc. under a Small Business Innovation Research (SBIR) contract. It is marketed to the water and wastewater treatment industries, replacing "grab sampling" with on-line data collection. It analyzes the light absorbance characteristics of a water sample, simultaneously detects hundreds of individual wavelengths absorbed by chemical substances in a process solution, and quantifies the information. Spectral data is then processed by ChemScan analyzer and compared with calibration files in the system's memory in order to calculate concentrations of chemical substances that cause UV light absorbance in specific patterns. Monitored substances can be analyzed for quality and quantity. Applications include detection of a variety of substances, and the information provided enables an operator to control a process more efficiently.

  19. BOREAS HYD-8 1996 Gravimetric Moss Moisture Data

    NASA Technical Reports Server (NTRS)

    Fernandes, Richard; Hall, Forrest G. (Editor); Knapp, David E. (Editor); Smith, David E. (Technical Monitor)

    2000-01-01

    The Boreal Ecosystem-Atmosphere Study (BOREAS) Hydrology (HYD)-8 team made measurements of surface hydrological processes that were collected at the southern study area-Old Black Spruce (SSA-OBS) Tower Flux site in 1996 to support its research into point hydrological processes and the spatial variation of these processes. Data collected may be useful in characterizing canopy interception, drip, throughfall, moss interception, drainage, evaporation, and capacity during the growing season at daily temporal resolution. This particular data set contains the gravimetric moss moisture measurements from July to August 1996. To collect these data, a nested spatial sampling plan was implemented to support research into spatial variations of the measured hydrological processes and ultimately the impact of these variations on modeled carbon and water budgets. These data are stored in ASCII text files. The HYD-08 1996 gravimetric moss moisture data are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC). The data files are available on a CD-ROM (see document number 20010000884).

  20. Matt waste from glass separated collection: an eco-sustainable addition for new building materials.

    PubMed

    Bignozzi, M C; Saccani, A; Sandrolini, F

    2009-01-01

    Matt waste (MW), a by-product of purification processes of cullet derived from separated glass waste collection, has been studied as filler for self-compacting concrete and as an addition for newly blended cement. Properties of self-compacting concrete compared to reference samples are reported. They include characteristics at the fresh and hardened states, and the compressive strength and porosity of mortar samples that were formulated with increasing amounts of MW to be used as cement replacement (up to 50wt.%). The effects of matt waste are discussed with respect to the mechanical and microstructural characteristics of the resulting new materials.

  1. Ecology of Arcobacter species in chicken rearing and processing.

    PubMed

    Gude, A; Hillman, T J; Helps, C R; Allen, V M; Corry, J E L

    2005-01-01

    To investigate whether Arcobacter spp. colonize the poultry-rearing environment or whether they are contaminants acquired during transportation and/or from the processing plant. Samples were collected on poultry farms and in the processing plant during slaughter and dressing. Two cultural methods of detection were used. Isolates were identified to species level using a multiplex-polymerase chain reaction (m-PCR) method, either on the initial suspensions, or after enrichment, or on pure cultures of isolates. Of the 62 samples examined from poultry farms, arcobacters were found only outside the rearing sheds (in effluent sludge and stagnant water). Thirty-four samples were examined from the processing plant and 26 were positive for arcobacters. All the isolates were Arcobacter butzleri. Arcobacters were not found in any sample by direct plating nor by m-PCR on the initial suspensions, thus it was concluded that numbers were very low. Arcobacter spp. were not found in samples from the live birds and their immediate environment, but A. butzleri was found in effluent sludge and stagnant water outside the rearing sheds. However, A. butzleri is common in poultry abattoirs, and it appears that poultry carcasses are contaminated during processing. Arcobacters are not found inside poultry-rearing sheds, but are contaminants in the processing environment.

  2. Spatial and Temporal Dynamics of Fecal Coliform and Associated with Suspended Solids and Water within Five Northern California Estuaries.

    PubMed

    Lewis, David J; Atwill, Edward R; Pereira, Maria das Graças C; Bond, Ronald

    2013-01-01

    Fecal coliform and associated with suspended solids (SS) and water in five northern California estuaries were studied to document process influences and water quality monitoring biases affecting indicator bacteria concentrations. We collected and analyzed 2371 samples during 10 sampling events for the five studied estuaries. Concentrations during wet-season stormflow conditions were greater than during wet-season base flow and dry-season base flow conditions. Results also document concentration gradients across the length of the studied estuaries and with depth of sample collection. Highest concentrations were associated with shallow samples collected furthest inland. Corresponding decreases occurred the deeper and closer to the estuary mouth a sample was collected. Results also identify direct relationships of wind speed and discharge velocity and indirect relationship of tide stage to indicator bacteria concentrations. Bacteria associated with suspended solids (SS), after conversion to the same units of measurement (mass), were three orders of magnitude greater than in the water fraction. However, the mean proportion contributed by SS to composite water sample concentrations was 8% (SE 0.3) for fecal coliform and 7% (SE 0.3) for . Bacteria from the SS proportion is related to seasonality, tide stage, and discharge velocity that are consistent with mechanisms for entrainment, transport of SS, and reduced particle settling. These results are important for both managing and monitoring these systems by improving sample spatial and temporal context and corresponding bacteria concentration values across the freshwater-saltwater interface. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  3. A Multiscale Approach to Modeling Carbon and Nitrogen Cycling within a High Elevation Watershed

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lawrence, Corey

    This funding represents a small sub-award related the larger project titled: A Multiscale Approach to Modeling Carbon and Nitrogen Cycling within a High Elevation Watershed. The goal of the sub-award was to facilitate the characterization of carbon and radiocarbon data collected from the East River watershed outside Gothic, Colorado USA. During the period of funding from 8/1/15 until 7/31/17, we sampled 40 soil profiles and collected ~325 soil samples. This funding supported the collection, processing, and elemental analysis of each of these samples. In addition, the funding allowed for the further density separation of a subset of soil resulting inmore » 60 measurements of 13C and 14C of bulk soil and density separates. Funding also supported installation of temperature and moisture data sensors arrays, soil gas wells, and soil water lysimeters. From this infrastructure, a steady stream data including soil gas, water, and physical information have been generated to support the larger research project.« less

  4. Geochemical changes in crude oil spilled from the Exxon Valdez supertanker into Prince William Sound, Alaska

    USGS Publications Warehouse

    Hostettler, Frances D.; Kvenvolden, Keith A.

    1994-01-01

    North Slope crude oil spilled from the T/V Exxon Valdez in March 1989 and contaminated about 500 km of Prince William Sound shoreline. Aliphatic and aromatic hydrocarbons in oil samples collected in August 1990 and June 1992 from beaches on six islands impacted by the spill have been compared with the hydrocarbons from North Slope crude oil taken from the stricken tanker. Degradation processes have changed the physical appearance of this residual spilled oil; the beached oil as collected ranged from a light brown color, to a heavy black viscous oil, to a black, powder-like residue. In these physically different samples, terpane, sterane, and aromatic sterane distributions, as well as carbon isotope values, are similar and correlate with the original Exxon Valdez oil. On the other hand, n-alkanes, isoprenoids, and many of the polycyclic aromatic hydrocarbons which are present in the original crude oil are dramatically altered in the oil samples collected from the beaches.

  5. Service-Learning General Chemistry: Lead Paint Analyses

    NASA Astrophysics Data System (ADS)

    Kesner, Laya; Eyring, Edward M.

    1999-07-01

    Houses painted with lead-based paints are ubiquitous in the United States because the houses and the paint have not worn out two decades after federal regulations prohibited inclusion of lead in paint. Remodeling older homes thus poses a health threat for infants and small children living in those homes. In a service-learning general chemistry class, students disseminate information about this health threat in an older neighborhood. At some of the homes they collect paint samples that they analyze for lead both qualitatively and quantitatively. This service-learning experience generates enthusiasm for general chemistry through the process of working on a "real" problem. Sample collection familiarizes the students with the concept of "representative" sampling. The sample preparation for atomic absorption spectroscopic (AAS) analysis enhances their laboratory skills. The focus of this paper is on the mechanics of integrating this particular service project into the first-term of the normal general chemistry course.

  6. A Multi-Decadal Sample Return Campaign Will Advance Lunar and Solar System Science and Exploration by 2050

    NASA Technical Reports Server (NTRS)

    Neal, C. R.; Lawrence, S. J.

    2017-01-01

    There have been 11 missions to the Moon this century, 10 of which have been orbital, from 5 different space agencies. China became the third country to successfully soft-land on the Moon in 2013, and the second to successfully remotely operate a rover on the lunar surface. We now have significant global datasets that, coupled with the 1990s Clementine and Lunar Prospector missions, show that the sample collection is not representative of the lithologies present on the Moon. The M3 data from the Indian Chandrayaan-1 mission have identified lithologies that are not present/under-represented in the sample collection. LRO datasets show that volcanism could be as young as 100 Ma and that significant felsic complexes exist within the lunar crust. A multi-decadal sample return campaign is the next logical step in advancing our understanding of lunar origin and evolution and Solar System processes.

  7. Radioactive sample effects on EDXRF spectra

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Worley, Christopher G

    2008-01-01

    Energy dispersive X-ray fluorescence (EDXRF) is a rapid, straightforward method to determine sample elemental composition. A spectrum can be collected in a few minutes or less, and elemental content can be determined easily if there is adequate energy resolution. Radioactive alpha emitters, however, emit X-rays during the alpha decay process that complicate spectral interpretation. This is particularly noticeable when using a portable instrument where the detector is located in close proximity to the instrument analysis window held against the sample. A portable EDXRF instrument was used to collect spectra from specimens containing plutonium-239 (a moderate alpha emitter) and americium-241 (amore » heavy alpha emitter). These specimens were then analyzed with a wavelength dispersive XRF (WDXRF) instrument to demonstrate the differences to which sample radiation-induced X-ray emission affects the detectors on these two types of XRF instruments.« less

  8. The role of the medical laboratory technologist in drinking and driving cases. Part 1: The Criminal Code and blood collection for alcohol analysis.

    PubMed

    Westenbrink, W

    1992-01-01

    Police officers can now demand blood samples from suspected impaired drivers in Canada to determine their Blood Alcohol Concentration. The medical laboratory technologist has been given the authority to take blood samples for legal purposes, as well as the authorization to complete certificates used as evidence in court. The proper procedures for the taking of blood samples and the completion of certificates are described in detail. The Criminal Code offences dealing with drinking and driving, the means by which police officers can legally obtain blood samples, the Blood Alcohol Kit, and the provision of providing blood collection evidence in court are discussed to aid the technologists in understanding their role in this process. The Criminal Code definitions of a "qualified medical practitioner", a "qualified technician", and "approved containers" are also described.

  9. Physicochemical equivalence of generic antihypertensive medicines (EQUIMEDS): protocol for a quality of medicines assessment

    PubMed Central

    Redfern, Julie; Adedoyin, Rufus Adesoji; Ofori, Sandra; Anchala, Raghupathy; Ajay, Vamadevan S; De Andrade, Luciano; Zelaya, Jose; Kaur, Harparkash; Balabanova, Dina; Sani, Mahmoud U

    2016-01-01

    Background Prevention and optimal management of hypertension in the general population is paramount to the achievement of the World Heart Federation (WHF) goal of reducing premature cardiovascular disease (CVD) mortality by 25% by the year 2025 and widespread access to good quality antihypertensive medicines is a critical component for achieving the goal. Despite research and evidence relating to other medicines such as antimalarials and antibiotics, there is very little known about the quality of generic antihypertensive medicines in low-income and middle-income countries. The aim of this study was to determine the physicochemical equivalence (percentage of active pharmaceutical ingredient, API) of generic antihypertensive medicines available in the retail market of a developing country. Methods An observational design will be adopted, which includes literature search, landscape assessment, collection and analysis of medicine samples. To determine physicochemical equivalence, a multistage sampling process will be used, including (1) identification of the 2 most commonly prescribed classes of antihypertensive medicines prescribed in Nigeria; (2) identification of a random sample of 10 generics from within each of the 2 most commonly prescribed classes; (3) a geographical representative sampling process to identify a random sample of 24 retail outlets in Nigeria; (4) representative sample purchasing, processing to assess the quality of medicines, storage and transport; and (5) assessment of the physical and chemical equivalence of the collected samples compared to the API in the relevant class. In total, 20 samples from each of 24 pharmacies will be tested (total of 480 samples). Discussion Availability of and access to quality antihypertensive medicines globally is therefore a vital strategy needed to achieve the WHF 25×25 targets. However, there is currently a scarcity of knowledge about the quality of antihypertensive medicines available in developing countries. Such information is important for enforcing and for ensuring the quality of antihypertensive medicines. PMID:28588941

  10. Cryopreservation in fish: current status and pathways to quality assurance and quality control in repository development

    PubMed Central

    Torres, Leticia; Hu, E.; Tiersch, Terrence R.

    2017-01-01

    Cryopreservation in aquatic species in general has been constrained to research activities for more than 60 years. Although the need for application and commercialisation pathways has become clear, the lack of comprehensive quality assurance and quality control programs has impeded the progress of the field, delaying the establishment of germplasm repositories and commercial-scale applications. In this review we focus on the opportunities for standardisation in the practices involved in the four main stages of the cryopreservation process: (1) source, housing and conditioning of fish; (2) sample collection and preparation; (3) freezing and cryogenic storage of samples; and (4) egg collection and use of thawed sperm samples. In addition, we introduce some key factors that would assist the transition to commercial-scale, high-throughput application. PMID:26739583

  11. Coffee husk composting: an investigation of the process using molecular and non-molecular tools.

    PubMed

    Shemekite, Fekadu; Gómez-Brandón, María; Franke-Whittle, Ingrid H; Praehauser, Barbara; Insam, Heribert; Assefa, Fassil

    2014-03-01

    Various parameters were measured during a 90-day composting process of coffee husk with cow dung (Pile 1), with fruit/vegetable wastes (Pile 2) and coffee husk alone (Pile 3). Samples were collected on days 0, 32 and 90 for chemical and microbiological analyses. C/N ratios of Piles 1 and 2 decreased significantly over the 90 days. The highest bacterial counts at the start of the process and highest actinobacterial counts at the end of the process (Piles 1 and 2) indicated microbial succession with concomitant production of compost relevant enzymes. Denaturing gradient gel electrophoresis of rDNA and COMPOCHIP microarray analysis indicated distinctive community shifts during the composting process, with day 0 samples clustering separately from the 32 and 90-day samples. This study, using a multi-parameter approach, has revealed differences in quality and species diversity of the three composts. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Archive of ground penetrating radar data collected during USGS field activity 13BIM01—Dauphin Island, Alabama, April 2013

    USGS Publications Warehouse

    Forde, Arnell S.; Smith, Christopher G.; Reynolds, Billy J.

    2016-03-18

    From April 13 to 20, 2013, scientists from the U.S. Geological Survey St. Petersburg Coastal and Marine Science Center (USGS-SPCMSC) conducted geophysical and sediment sampling surveys on Dauphin Island, Alabama, as part of Field Activity 13BIM01. The objectives of the study were to quantify inorganic and organic accretion rates in back-barrier and mainland marsh and estuarine environments. Various field and laboratory methods were used to achieve these objectives, including subsurface imaging using Ground Penetrating Radar (GPR), sediment sampling, lithologic and microfossil analyses, and geochronology techniques to produce barrier island stratigraphic cross sections to help interpret the recent (last 2000 years) geologic evolution of the island.This data series report is an archive of GPR and associated Global Positioning System (GPS) data collected in April 2013 from Dauphin Island and adjacent barrier-island environments. In addition to GPR data, marsh core and vibracore data were also collected collected but are not reported (or included) in the current report. Data products, including elevation-corrected subsurface profile images of the processed GPR data, unprocessed digital GPR trace data, post-processed GPS data, Geographic Information System (GIS) files and accompanying Federal Geographic Data Committee (FGDC) metadata, can be downloaded from the Data Downloads page.

  13. Determining the sources of suspended sediment in a Mediterranean groundwater-dominated river: the Na Borges basin (Mallorca, Spain).

    NASA Astrophysics Data System (ADS)

    Estrany, Joan; Martinez-Carreras, Nuria

    2013-04-01

    Tracers have been acknowledged as a useful tool to identify sediment sources, based upon a variety of techniques and chemical and physical sediment properties. Sediment fingerprinting supports the notion that changes in sedimentation rates are not just related to increased/reduced erosion and transport in the same areas, but also to the establishment of different pathways increasing sediment connectivity. The Na Borges is a Mediterranean lowland agricultural river basin (319 km2) where traditional soil and water conservation practices have been applied over millennia to provide effective protection of cultivated land. During the twentieth century, industrialisation and pressure from tourism activities have increased urbanised surfaces, which have impacts on the processes that control streamflow. Within this context, source material sampling was focused in Na Borges on obtaining representative samples from potential sediment sources (comprised topsoil; i.e., 0-2 cm) susceptible to mobilisation by water and subsequent routing to the river channel network, while those representing channel bank sources were collected from actively eroding channel margins and ditches. Samples of road dust and of solids from sewage treatment plants were also collected. During two hydrological years (2004-2006), representative suspended sediment samples for use in source fingerprinting studies were collected at four flow gauging stations and at eight secondary sampling points using time-integrating sampling samplers. Likewise, representative bed-channel sediment samples were obtained using the resuspension approach at eight sampling points in the main stem of the Na Borges River. These deposits represent the fine sediment temporarily stored in the bed-channel and were also used for tracing source contributions. A total of 102 individual time-integrated sediment samples, 40 bulk samples and 48 bed-sediment samples were collected. Upon return to the laboratory, source material samples were oven-dried at 40° C, disaggregated using a pestle and mortar, and dry sieved to

  14. Ammonia in ground water from the Mississippi River alluvium, Fort Madison, Iowa

    USGS Publications Warehouse

    Linhart, S. Mike

    2001-01-01

    Water samples were collected from three municipal wells, two industrial wells, one watersupply well at the Iowa State Penitentiary, one domestic well, two creeks, and the Mississippi River. Tritium analytical results indicate that the time of recharge was after 1953 for water from the municipal wells (where tritium samples were collected). The ammonia concentration, 5.1 milligrams per liter, was considerably higher in ground water collected from well Fort Madison #4 compared to samples collected from other wells. The dissolved organic carbon concentration was also highest in ground water collected from well Fort Madison #4 (5.5 milligrams per liter) although samples from other wells were also relatively high, 2.6 to 5.3 milligrams per liter. The most likely process producing the high ammonia concentration in ground water in the vicinity of well Fort Madison #4 is decomposition of organic matter (ammonification). Nitrogen isotope values, when compared to nitrogen isotope values found in ground water in the vicinity of some of the other wells, indicate the possibility that a higher percentage of the ammonia found in ground water in the vicinity of well Fort Madison #4 may be from human and(or) other animal wastes. Higher concentrations of dissolved phosphorus, orthophosphate, and a higher chloride-to-sodium mole ratio found in ground water sampled from well Fort Madison #4 could be indicative of a sewage or septic source. Potential sources include existing or abandoned septic systems, leaking sanitary sewer lines, commercial or residential waste-disposal sites, and agricultural runoff upgradient from well Fort Madison #4, or possibly, bed sediments of the Mississippi River.

  15. Review of samples of water, sediment, tailings, and biota at the Little Bonanza mercury mine, San Luis Obispo County, California

    USGS Publications Warehouse

    Rytuba, James J.; Hothem, Roger L.; Goldstein, Daniel N.; Brussee, Brianne E.; May, Jason T.

    2011-01-01

    Sample Sites and Methods Samples were collected to assess the concentrations of Hg and biogeochemically relevant constituents in tailings and wasterock piles at the Little Bonanza Hg mine. Tailings are present adjacent to a three-pipe retort used to process the Hg ore. The tailings occur in the upper 15 cm of the soil adjacent to the retort and slag from the retort is present on the surface. An area of disturbed soil and rock uphill from the retort was likely formed during construction of a dam that provided water for mining activities. Wasterock in these piles was sampled. The largest amount of tailings is exposed to the west of the retort in the bank of WF Las Tablas Creek. Water, sediment, and biota were sampled from WF Las Tablas Creek, which flows through the mine area. Sample-site locations are shown in figures 10 and 11 and listed in table 1. Samples were collected when streamflow was low and no precipitation had occurred.

  16. Simultaneous monitoring of faecal indicators and harmful algae using an in-situ autonomous sensor.

    PubMed

    Yamahara, K M; Demir-Hilton, E; Preston, C M; Marin, R; Pargett, D; Roman, B; Jensen, S; Birch, J M; Boehm, A B; Scholin, C A

    2015-08-01

    Faecal indicator bacteria (FIB) and harmful algal blooms (HABs) threaten the health and the economy of coastal communities worldwide. Emerging automated sampling technologies combined with molecular analytical techniques could enable rapid detection of micro-organisms in-situ, thereby improving resource management and public health decision-making. We evaluated this concept using a robotic device, the Environmental Sample Processor (ESP). The ESP automates in-situ sample collection, nucleic acid extraction and molecular analyses. Here, the ESP measured and reported concentrations of FIB (Enterococcus spp.), a microbial source-tracking marker (human-specific Bacteriodales) and a HAB species (Psuedo-nitzschia spp.) over a 45-day deployment on the Santa Cruz Municipal Wharf (Santa Cruz, CA, USA). Both FIB and HABs were enumerated from single in-situ collected water samples. The in-situ qPCR efficiencies ranged from 86% to 105%, while the limit of quantifications during the deployment was 10 copies reaction(-1) . No differences were observed in the concentrations of enterococci, the human-specific marker in Bacteroidales spp., and P. australis between in-situ collected sample and traditional hand sampling methods (P > 0·05). Analytical results were Internet-accessible within hours of sample collection, demonstrating the feasibility of same-day public notification of current water quality conditions. This study presents the first report of in-situ qPCR enumeration of both faecal indicators and harmful algal species in coastal marine waters. We utilize a robotic device for in-situ quantification of enterococci, the human-specific marker in Bacteriodales and Pseudo-nitzschia spp. from the same water samples collected and processed in-situ. The results demonstrate that rapid, in-situ monitoring can be utilized to identify and quantify multiple health-relevant micro-organisms important in water quality monitoring and that this monitoring can be used to inform same-day notifications. © 2015 The Society for Applied Microbiology.

  17. Stability of hematologic analytes in monkey, rabbit, rat, and mouse blood stored at 4°C in EDTA using the ADVIA 120 hematology analyzer.

    PubMed

    Ameri, Mehrdad; Schnaars, Henry A; Sibley, John R; Honor, David J

    2011-06-01

    The time from sampling to analysis can be delayed when blood samples are shipped to distant reference laboratories or when analysis cannot be readily performed. The objective of this study was to evaluate the stability of hematologic analytes in blood samples from monkeys, rabbits, rats, and mice when samples were stored for up to 72 hours at 4°C. Blood samples from 30 monkeys, 15 rabbits, 20 rats, and 30 mice were collected into EDTA-containing tubes and were initially analyzed within 1 hour of collection using the ADVIA 120 analyzer. The samples were then stored at 4°C and reanalyzed at 24, 48, and 72 hours after collection. Significant (P<.0003) changes in hematologic analytes and calculations included increased HCT and MCV and decreased MCHC and cell hemoglobin concentration mean (CHCM) at 72 hours and increased MPV at 24 hours in monkeys; increased MCV at 72 hours and MPV at 48 hours and decreased monocyte count at 24 hours in rabbits; increased MCV and decreased MCHC, CHCM, and monocyte count at 24 hours in rats; increased MCV, red cell distribution width, and MPV and decreased MCHC, CHCM, and monocyte count at 24 hours in mice. Although most of the changes in the hematologic analytes in blood from monkeys, rabbits, rats, and mice when samples were stored at 4°C were analytically acceptable and clinically negligible, the best practice in measuring hematologic analytes in these animals is timely processing of blood samples, preferably within 1 hour after collection. ©2011 American Society for Veterinary Clinical Pathology.

  18. Trace element and Nd, Sr, Pb isotope geochemistry of Kilauea Volcano, Hawai'i, near-vent eruptive products: 1983-2001

    USGS Publications Warehouse

    Thornber, Carl R.; Budahn, James R.; Ridley, W. Ian; Unruh, Daniel M.

    2003-01-01

    This open-file report serves as a repository for geochemical data referred to in U.S. Geological Survey Professional Paper 1676 (Heliker, Swanson, and Takahashi, eds., 2003), which includes multidisciplinary research papers pertaining to the first twenty years of Puu Oo Kupaianaha eruption activity. Details of eruption characteristics and nomenclature are provided in the introductory chapter of that volume (Heliker and Mattox, 2003). Geochemical relations of this data are depicted and interpreted by Thornber (2003), Thornber and others (2003a) and Thornber (2001). This report supplements Thornber and others (2003b) in which whole-rock and glass major-element data on ~1000 near-vent lava samples collected during the 1983 to 2001 eruptive interval of Kilauea Volcano, Hawai'i, are presented. Herein, we present whole-rock trace element compositions of 85 representative samples collected from January 1983 to May 2001; glass trace-element compositions of 39 Pele’s Tear (tephra) samples collected from September 1995 to September 1996, and whole-rock Nd, Sr and Pb isotopic analyses of 10 representative samples collected from September 1983 to September 1993. Thornber and others (2003b) provide a specific record of sample characteristics, location, etc., for each of the samples reported here. Spreadsheets of both reports may be integrated and sorted based upon time of formation or sample numbers. General information pertaining to the selectivity and petrologic significance of this sample suite is presented by Thornber and others (2003b). As justified in that report, this select suite of time-constrained geochemical data is suitable for constructing petrologic models of pre-eruptive magmatic processes associated with prolonged rift zone eruption of Hawaiian shield volcanoes.

  19. 40 CFR 63.694 - Testing methods and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... determine treatment process required HAP biodegradation efficiency (Rbio) for compliance with standards... procedures to minimize the loss of compounds due to volatilization, biodegradation, reaction, or sorption... compounds due to volatilization, biodegradation, reaction, or sorption during the sample collection, storage...

  20. 40 CFR 63.694 - Testing methods and procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... determine treatment process required HAP biodegradation efficiency (Rbio) for compliance with standards... procedures to minimize the loss of compounds due to volatilization, biodegradation, reaction, or sorption... compounds due to volatilization, biodegradation, reaction, or sorption during the sample collection, storage...

  1. 40 CFR 63.694 - Testing methods and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... determine treatment process required HAP biodegradation efficiency (Rbio) for compliance with standards... procedures to minimize the loss of compounds due to volatilization, biodegradation, reaction, or sorption... compounds due to volatilization, biodegradation, reaction, or sorption during the sample collection, storage...

  2. Prevalence of internal parasites in beef cows in the United States: Results of the National Animal Health Monitoring System's (NAHMS) beef study, 2007-2008.

    PubMed

    Stromberg, Bert E; Gasbarre, Louis C; Ballweber, Lora R; Dargatz, David A; Rodriguez, Judith M; Kopral, Christine A; Zarlenga, Dante S

    2015-10-01

    During the United States Department of Agriculture (USDA) National Animal Health Monitoring System's (NAHMS) 2007-2008 beef study, 567 producers from 24 US States were offered the opportunity to collect fecal samples from weaned beef calves and have them evaluated for the presence of parasite eggs (Phase 1). Participating producers were provided with instructions and materials for sample collection. Up to 20 fresh fecal samples were collected from each of the 99 participating operations. Fresh fecal samples were submitted to one of 3 randomly assigned laboratories for evaluation. Upon arrival at the laboratories, all samples were processed for the enumeration of strongyle, Nematodirus, and Trichuris eggs using the modified Wisconsin technique. The presence or absence of coccidian oocysts and tapeworm eggs was also noted. In submissions where the strongyle eggs per gram exceeded 30, aliquots from 2 to 6 animals were pooled for DNA extraction. Extracted DNA was subjected to genus level polymerase chain reaction (PCR) identification for the presence of Ostertagia, Cooperia, Haemonchus, Oesophagostomum, and Trichostrongylus. In this study, 85.6% of the samples had strongyle type, Nematodirus, and Trichuris eggs. Among the samples evaluated, 91% had Cooperia, 79% Ostertagia, 53% Haemonchus, 38% Oesophagostomum, 18% Nematodirus, 7% Trichuris, and 3% Trichostrongylus. The prevalence of coccidia and tapeworm eggs was 59.9% and 13.7%, respectively.

  3. Prevalence of internal parasites in beef cows in the United States: Results of the National Animal Health Monitoring System’s (NAHMS) beef study, 2007–2008

    PubMed Central

    Stromberg, Bert E.; Gasbarre, Louis C.; Ballweber, Lora R.; Dargatz, David A.; Rodriguez, Judith M.; Kopral, Christine A.; Zarlenga, Dante S.

    2015-01-01

    During the United States Department of Agriculture (USDA) National Animal Health Monitoring System’s (NAHMS) 2007–2008 beef study, 567 producers from 24 US States were offered the opportunity to collect fecal samples from weaned beef calves and have them evaluated for the presence of parasite eggs (Phase 1). Participating producers were provided with instructions and materials for sample collection. Up to 20 fresh fecal samples were collected from each of the 99 participating operations. Fresh fecal samples were submitted to one of 3 randomly assigned laboratories for evaluation. Upon arrival at the laboratories, all samples were processed for the enumeration of strongyle, Nematodirus, and Trichuris eggs using the modified Wisconsin technique. The presence or absence of coccidian oocysts and tapeworm eggs was also noted. In submissions where the strongyle eggs per gram exceeded 30, aliquots from 2 to 6 animals were pooled for DNA extraction. Extracted DNA was subjected to genus level polymerase chain reaction (PCR) identification for the presence of Ostertagia, Cooperia, Haemonchus, Oesophagostomum, and Trichostrongylus. In this study, 85.6% of the samples had strongyle type, Nematodirus, and Trichuris eggs. Among the samples evaluated, 91% had Cooperia, 79% Ostertagia, 53% Haemonchus, 38% Oesophagostomum, 18% Nematodirus, 7% Trichuris, and 3% Trichostrongylus. The prevalence of coccidia and tapeworm eggs was 59.9% and 13.7%, respectively. PMID:26424909

  4. Data sharing report characterization of the surveillance and maintenance project miscellaneous process inventory waste items Oak Ridge National Laboratory, Oak Ridge, TN

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weaver, Phyllis C.

    2013-12-12

    The U.S. Department of Energy (DOE) Oak Ridge Office of Environmental Management (EM-OR) requested Oak Ridge Associated Universities (ORAU), working under the Oak Ridge Institute for Science and Education (ORISE) contract, to provide technical and independent waste management planning support under the American Recovery and Reinvestment Act (ARRA). Specifically, DOE EM-OR requested ORAU to plan and implement a sampling and analysis campaign to target certain items associated with URS|CH2M Oak Ridge, LLC (UCOR) surveillance and maintenance (S&M) process inventory waste. Eight populations of historical and reoccurring S&M waste at the Oak Ridge National Laboratory (ORNL) have been identified in themore » Waste Handling Plan for Surveillance and Maintenance Activities at the Oak Ridge National Laboratory, DOE/OR/01-2565&D2 (WHP) (DOE 2012) for evaluation and processing for final disposal. This waste was generated during processing, surveillance, and maintenance activities associated with the facilities identified in the process knowledge (PK) provided in Appendix A. A list of items for sampling and analysis were generated from a subset of materials identified in the WHP populations (POPs) 4, 5, 6, 7, and 8, plus a small number of items not explicitly addressed by the WHP. Specifically, UCOR S&M project personnel identified 62 miscellaneous waste items that would require some level of evaluation to identify the appropriate pathway for disposal. These items are highly diverse, relative to origin; composition; physical description; contamination level; data requirements; and the presumed treatment, storage, and disposal facility (TSDF). Because of this diversity, ORAU developed a structured approach to address item-specific data requirements necessary for acceptance in a presumed TSDF that includes the Environmental Management Waste Management Facility (EMWMF)—using the approved Waste Lot (WL) 108.1 profile—the Y-12 Sanitary Landfill (SLF) if appropriate; EnergySolutions Clive; and the Nevada National Security Site (NNSS) (ORAU 2013b). Finally, the evaluation of these wastes was more suited to a judgmental sampling approach rather than a statistical design, meaning data were collected for each individual item, thereby providing information for item-byitem disposition decisions. ORAU prepared a sampling and analysis plan (SAP) that outlined data collection strategies, methodologies, and analytical guidelines and requirements necessary for characterizing targeted items (ORAU 2013b). The SAP described an approach to collect samples that allowed evaluation as to whether or not the waste would be eligible for disposal at the EMWMF. If the waste was determined not to be eligible for EMWMF disposal, then there would be adequate information collected that would allow the waste to be profiled for one of the alternate TSDFs listed above.« less

  5. Cryopreservation for delayed circulating tumor cell isolation is a valid strategy for prognostic association of circulating tumor cells in gastroesophageal cancer.

    PubMed

    Brungs, Daniel; Lynch, David; Luk, Alison Ws; Minaei, Elahe; Ranson, Marie; Aghmesheh, Morteza; Vine, Kara L; Carolan, Martin; Jaber, Mouhannad; de Souza, Paul; Becker, Therese M

    2018-02-21

    To demonstrate the feasibility of cryopreservation of peripheral blood mononuclear cells (PBMCs) for prognostic circulating tumor cell (CTC) detection in gastroesophageal cancer. Using 7.5 mL blood samples collected in EDTA tubes from patients with gastroesopheagal adenocarcinoma, CTCs were isolated by epithelial cell adhesion molecule based immunomagnetic capture using the IsoFlux platform. Paired specimens taken during the same blood draw ( n = 15) were used to compare number of CTCs isolated from fresh and cryopreserved PBMCs. Blood samples were processed within 24 h to recover the PBMC fraction, with PBMCs used for fresh analysis immediately processed for CTC isolation. Cryopreservation of PBMCs lasted from 2 wk to 25.2 mo (median 14.6 mo). CTCs isolated from pre-treatment cryopreserved PBMCs ( n = 43) were examined for associations with clinicopathological variables and survival outcomes. While there was a significant trend to a decrease in CTC numbers associated with cryopreserved specimens (mean number of CTCs 34.4 vs 51.5, P = 0.04), this was predominately in samples with a total CTC count of > 50, with low CTC count samples less affected ( P = 0.06). There was no significant association between the duration of cryopreservation and number of CTCs. In cryopreserved PBMCs from patient samples prior to treatment, a high CTC count (> 17) was associated with poorer overall survival (OS) ( n = 43, HR = 4.4, 95%CI: 1.7-11.7, P = 0.0013). In multivariate analysis, after controlling for sex, age, stage, ECOG performance status, and primary tumor location, a high CTC count remained significantly associated with a poorer OS (HR = 3.7, 95%CI: 1.2-12.4, P = 0.03). PBMC cryopreservation for delayed CTC isolation is a valid strategy to assist with sample collection, transporting and processing.

  6. Institutional practices and policies in acid-base testing: a self reported Croatian survey study on behalf of the Croatian society of medical biochemistry and laboratory medicine Working Group for acid-base balance.

    PubMed

    Dukić, Lora; Simundić, Ana-Maria

    2014-01-01

    The aim of this survey study was to assess the current practices and policies in use related to the various steps in the blood gas testing process, across hospital laboratories in Croatia. First questionnaire was sent by email to all medical biochemistry laboratories (N = 104) within general, specialized and clinical hospitals and university hospital centres to identify laboratories which perform blood gas analysis. Second questionnaire with detailed questions about sample collection, analysis and quality control procedures, was sent only to 47 laboratories identified by the first survey. Questionnaire was designed as combination of questions and statements with Likert scale. Third questionnaire was sent to all participating laboratories (N=47) for additional clarification for either indeterminate or unclear answers. Blood gas analysis is performed in 47/104 hospital laboratories in Croatia. In 25/41 (0.61) of the laboratories capillary blood gas sampling is the preferred sample type for adult patient population, whereas arterial blood sample is preferentially used in only 5/44 laboratories (0.11). Blood sampling and sample processing for capillary samples is done almost always by laboratory technicians (36/41 and 37/44, respectively), whereas arterial blood sampling is almost always done by the physician (24/29) and only rarely by a nurse (5/28). Sample acceptance criteria and sample analysis are in accordance with international recommendations for majority of laboratories. 43/44 laboratories participate in the national EQA program. POCT analyzers are installed outside of the laboratory in 20/47 (0.43) institutions. Laboratory staff is responsible for education and training of ward personnel, quality control and instrument maintenance in only 12/22, 11/20 and 9/20 institutions, respectively. Practices related to collection and analysis for blood gases in Croatia are not standardised and vary substantially between laboratories. POCT analyzers are not under the direct supervision by laboratory personnel in a large proportion of surveyed institutions. Collective efforts should be made to harmonize and improve policies and procedures related to blood gas testing in Croatian laboratories.

  7. Planning for the Collection and Analysis of Samples of Martian Granular Materials Potentially to be Returned by Mars Sample Return

    NASA Astrophysics Data System (ADS)

    Carrier, B. L.; Beaty, D. W.

    2017-12-01

    NASA's Mars 2020 rover is scheduled to land on Mars in 2021 and will be equipped with a sampling system capable of collecting rock cores, as well as a specialized drill bit for collecting unconsolidated granular material. A key mission objective is to collect a set of samples that have enough scientific merit to justify returning to Earth. In the case of granular materials, we would like to catalyze community discussion on what we would do with these samples if they arrived in our laboratories, as input to decision-making related to sampling the regolith. Numerous scientific objectives have been identified which could be achieved or significantly advanced via the analysis of martian rocks, "regolith," and gas samples. The term "regolith" has more than one definition, including one that is general and one that is much more specific. For the purpose of this analysis we use the term "granular materials" to encompass the most general meaning and restrict "regolith" to a subset of that. Our working taxonomy includes the following: 1) globally sourced airfall dust (dust); 2) saltation-sized particles (sand); 3) locally sourced decomposed rock (regolith); 4) crater ejecta (ejecta); and, 5) other. Analysis of martian granular materials could serve to advance our understanding areas including habitability and astrobiology, surface-atmosphere interactions, chemistry, mineralogy, geology and environmental processes. Results of these analyses would also provide input into planning for future human exploration of Mars, elucidating possible health and mechanical hazards caused by the martian surface material, as well as providing valuable information regarding available resources for ISRU and civil engineering purposes. Results would also be relevant to matters of planetary protection and ground-truthing orbital observations. We will present a preliminary analysis of the following, in order to generate community discussion and feedback on all issues relating to: What are the specific reasons (and their priorities) for collecting samples of granular materials? How do those reasons translate to sampling priorities? In what condition would these samples be expected to be received? What is our best projection of the approach by which these samples would be divided, prepared, and analyzed to achieve our objectives?

  8. Effect of a traditional processing method on the chemical composition of local white lupin (Lupinus albus L.) seed in North-Western Ethiopia.

    PubMed

    Yeheyis, Likawent; Kijora, Claudia; Wink, Michael; Peters, Kurt J

    2011-01-01

    The effect of a traditional Ethiopian lupin processing method on the chemical composition of lupin seed samples was studied. Two sampling districts, namely Mecha and Sekela, representing the mid- and high-altitude areas of north-western Ethiopia, respectively, were randomly selected. Different types of traditionally processed and marketed lupin seed samples (raw, roasted, and finished) were collected in six replications from each district. Raw samples are unprocessed, and roasted samples are roasted using firewood. Finished samples are those ready for human consumption as snack. Thousand seed weight for raw and roasted samples within a study district was similar (P > 0.05), but it was lower (P < 0.01) for finished samples compared to raw and roasted samples. The crude fibre content of finished lupin seed sample from Mecha was lower (P < 0.01) than that of raw and roasted samples. However, the different lupin samples from Sekela had similar crude fibre content (P > 0.05). The crude protein and crude fat contents of finished samples within a study district were higher (P < 0.01) than those of raw and roasted samples, respectively. Roasting had no effect on the crude protein content of lupin seed samples. The crude ash content of raw and roasted lupin samples within a study district was higher (P < 0.01) than that of finished lupin samples of the respective study districts. The content of quinolizidine alkaloids of finished lupin samples was lower than that of raw and roasted samples. There was also an interaction effect between location and lupin sample type. The traditional processing method of lupin seeds in Ethiopia has a positive contribution improving the crude protein and crude fat content, and lowering the alkaloid content of the finished product. The study showed the possibility of adopting the traditional processing method to process bitter white lupin for the use as protein supplement in livestock feed in Ethiopia, but further work has to be done on the processing method and animal evaluation.

  9. External quality-assurance programs managed by the U.S. Geological Survey in support of the National Atmospheric Deposition Program/National Trends Network

    USGS Publications Warehouse

    Latysh, Natalie E.; Wetherbee, Gregory A.

    2005-01-01

    The U.S. Geological Survey, Branch of Quality Systems, operates the external quality-assurance programs for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN). Beginning in 1978, six different programs have been implemented?the intersite-comparison program, the blind-audit program, the sample-handling evaluation program, the field-audit program, the interlaboratory-comparison program, and the collocated-sampler program. Each program was designed to measure error contributed by specific components in the data-collection process. The intersite-comparison program, which was discontinued in 2004, was designed to assess the accuracy and reliability of field pH and specific-conductance measurements made by site operators. The blind-audit and sample-handling evaluation programs, which also were discontinued in 2002 and 2004, respectively, assessed contamination that may result from sampling equipment and routine handling and processing of the wet-deposition samples. The field-audit program assesses the effects of sample handling, processing, and field exposure. The interlaboratory-comparison program evaluates bias and precision of analytical results produced by the contract laboratory for NADP, the Illinois State Water Survey, Central Analytical Laboratory, and compares its performance with the performance of international laboratories. The collocated-sampler program assesses the overall precision of wet-deposition data collected by NADP/NTN. This report documents historical operations and the operating procedures for each of these external quality-assurance programs. USGS quality-assurance information allows NADP/NTN data users to discern between actual environmental trends and inherent measurement variability.

  10. Factors controlling the regional distribution of vanadium in ground water

    USGS Publications Warehouse

    Wright, Michael T.; Belitz, Kenneth

    2010-01-01

    Although the ingestion of vanadium (V) in drinking water may have possible adverse health effects, there have been relatively few studies of V in groundwater. Given the importance of groundwater as a source of drinking water in many areas of the world, this study examines the potential sources and geochemical processes that control the distribution of V in groundwater on a regional scale. Potential sources of V to groundwater include dissolution of V rich rocks, and waste streams from industrial processes. Geochemical processes such as adsorption/desorption, precipitation/dissolution, and chemical transformations control V concentrations in groundwater. Based on thermodynamic data and laboratory studies, V concentrations are expected to be highest in samples collected from oxic and alkaline groundwater. However, the extent to which thermodynamic data and laboratory results apply to the actual distribution of V in groundwater is not well understood. More than 8400 groundwater samples collected in California were used in this study. Of these samples, high (> or = 50 μg/L) and moderate (25 to 49 μg/L) V concentrations were most frequently detected in regions where both source rock and favorable geochemical conditions occurred. The distribution of V concentrations in groundwater samples suggests that significant sources of V are mafic and andesitic rock. Anthropogenic activities do not appear to be a significant contributor of V to groundwater in this study. High V concentrations in groundwater samples analyzed in this study were almost always associated with oxic and alkaline groundwater conditions, which is consistent with predictions based on thermodynamic data.

  11. [The airborne 1,3-butadiene concentrations in rubber and plastic processing plants].

    PubMed

    Yoshida, Toshiaki; Tainaka, Hidetsugu; Matsunaga, Ichiro; Goto, Sumio

    2002-03-01

    Environment pollution by 1,3-butadiene had considerably increased in Japan. The main cause of the pollution is the automotive exhaust gas, and leaks from factories, smoking, and burning of rubber and plastic products are considered to be minor sources. The object of this study was to determine the contamination levels of airborne 1,3-butadiene in factories processing rubber and plastics containing 1,3-butadiene. The concentrations of airborne 1,3-butadiene were measured in 21 plants (10 rubber processing plants and 11 plastics processing plants) in Osaka. 1,3-Butadiene in air was collected for 10 minutes with a charcoal tube and a portable small pump adjusted to a 250 ml/min flow rate. In each plant, indoor air samples at five points and an outdoor air sample at one point outside the plant were collected. The samples were subjected to gas chromatography/mass spectrometry after thermal desorption from the charcoal. The concentrations of airborne 1,3-butadiene in the rubber processing plants and the plastics processing plants were 0.14-2.20 micrograms/m3 (geometric mean: 0.48 microgram/m3) and 0.23-4.51 micrograms/m3 (geometric mean: 0.80 microgram/m3), respectively. In all plants examined, indoor 1,3-butadiene concentrations were higher than the outdoor concentrations around the plants. Therefore, 1,3-butadiene was considered to arise from the processing of rubber or plastics, but the indoor 1,3-butadiene concentrations were much lower than the PEL-TWA (1 ppm = 2.21 mg/m3) of OSHA and the TLV-TWA (2 ppm) of ACGIH. The concentrations in the plants with closed room conditions without ventilation were higher than the concentrations in the other plants. It was suggested that ventilation affected the 1,3-butadiene concentration in the plants.

  12. Immunodetection and molecular determination of visceral and cutaneous Leishmania infection using patients' urine.

    PubMed

    Mirzaei, Asad; Ahmadipour, Fereshteh; Cannet, Arnaud; Marty, Pierre; Delaunay, Pascal; Perrin, Pascale; Dorkeld, Franck; Sereno, Denis; Akhoundi, Mohammad

    2018-05-27

    The diagnosis of leishmaniasis relies mainly on the use of invasive processes, to collect the biological material for detecting Leishmania parasites. Body fluids, which can be collected by non-invasive process, would greatly facilitate the leishmaniasis diagnosis. In the present study, we investigated the potency of urine immunoblotting to diagnose cutaneous and visceral leishmaniasis and we compared with routine molecular methods. A total of 80 samples, including 40 sera and their 40 corresponding urine samples were collected from 37 suspected patients with cutaneous and visceral leishmaniasis, and 3 healthy individuals (as control), in Ilam and Ardabil provinces of Iran. All sera and urine samples were analyzed, using immunoblotting. The confirmation of leishmaniasis infection was performed, using conventional and quantitative PCRs as well as by sequencing the amplicons. Among 37 suspected patients, 23 patients presented cutaneous lesions (CL) and 14 exhibited clinical symptoms reminiscent of visceral leishmaniasis (L. infantum). Among cutaneous patients, 15 were positive for zoonotic cutaneous leishmaniasis (L. major), and eight for anthroponotic cutaneous leishmaniasis (L. tropica). Molecular quantification of Leishmania parasites was performed on sera, urines and cutaneous biopsies of CL and VL patients, demonstrating that parasite load is lower in urines, compared to sera or biopsy. DNA can be detected in 20 out of 23 (86.9%) CL urine samples and in 13 out of 14 (92.8%) VL urine samples. Immunodetection analysis demonstrates that 22 out of 23 (95.6%) sera from CL patients and all patients suspected with VL are positive. For urine samples, 18 out of 23 (78.2%) urine of CL patients and 13 out of 14 (92.8%) urine of VL patients were positive, using Western blot. Therefore, immunodetection and molecular analysis using urine samples can be used as a diagnostic tool for surveying cutaneous and visceral leishmaniasis. Copyright © 2017. Published by Elsevier B.V.

  13. Desired Student Preparation in the Job Application Process as Perceived by the Business Community.

    ERIC Educational Resources Information Center

    Allen, Thomas R., Jr., Comp.

    The major purpose of this study was to determine from the business community what competencies in the job application process are needed by students preparing to enter the job market for their first full-time position. Data were collected from 100 human resource administrators (out of a sample of 400). The general feeling of the administrators was…

  14. Application of mass spectrometry to process control for polymer material in autoclave curing

    NASA Technical Reports Server (NTRS)

    Smith, A. C.

    1983-01-01

    Mass spectrometer analysis of gas samples collected during a cure cycle of polymer materials can be used as a process control technique. This technique is particularly helpful in studying the various types of solvents and resin systems used in the preparation of polymer materials and characterizing the chemical composition of different resin systems and their mechanism of polymerization.

  15. A Grounded Theory of Text Revision Processes Used by Young Adolescents Who Are Deaf

    ERIC Educational Resources Information Center

    Yuknis, Christina

    2014-01-01

    This study examined the revising processes used by 8 middle school students who are deaf or hard-of-hearing as they composed essays for their English classes. Using grounded theory, interviews with students and teachers in one middle school, observations of the students engaging in essay creation, and writing samples were collected for analysis.…

  16. Exploring Effects of High School Students' Mathematical Processing Skills and Conceptual Understanding of Chemical Concepts on Algorithmic Problem Solving

    ERIC Educational Resources Information Center

    Gultepe, Nejla; Yalcin Celik, Ayse; Kilic, Ziya

    2013-01-01

    The purpose of the study was to examine the effects of students' conceptual understanding of chemical concepts and mathematical processing skills on algorithmic problem-solving skills. The sample (N = 554) included grades 9, 10, and 11 students in Turkey. Data were collected using the instrument "MPC Test" and with interviews. The MPC…

  17. Aflatoxin M1 in processed milk: Occurrence and seasonal variation with an emphasis on risk assessment of human exposure in Serbia

    NASA Astrophysics Data System (ADS)

    Milićević, D.; Spirić, D.; Janković, S.; Velebit, B.; Radičević, T.; Petrović, Z.; Stefanović, S.

    2017-09-01

    The objectives of this study were to assess aflatoxin M1 (AFM1) contamination in processed milk and dairy products, and to estimate the mean daily exposure of the adult Serbian population to AFM1 due to milk consumption. A total of 1734 samples, comprising heat treated cow’s milk (n=1233), infant formulae (n=349), milk powder (n=94) and dairy drink (n=58), were analyzed for AFM1 presence using an Enzyme-Linked Immunosorbent Assay (ELISA) commercial kit. Samples were collected from different regions of Serbia during four seasons each year during 2015 and 2016. The incidences of AFM1 contamination were 77.8% with a mean level of 0.027±0.03 μg/L (range of <0.005-0.278 μg/L) in samples collected in 2015, and 98.4% with a mean level of 0.039±0.02 μg/L (range of <0.005-0.28 μg/L) in samples collected in 2016. The highest AFM1 levels were measured in October 2015 (0.278 μg/L) and September 2016 (0.279 μg/L). Based on EU regulation, 214 (17.3%) milk samples exceeded the maximum residue limit (0.05 μg/L). The estimated daily intake (EDI) of AFM1 during different seasons of year for males and females was in the range of 0.022-0.330 (mean 0.20) ng/kg/bw/day and 0.022-0.30 (mean 0.18) ng/kg/bw/day, respectively. The calculated EDI indicate a public health concern due to the carcinogenic effects of AFM1.

  18. Estimating time-dependent ROC curves using data under prevalent sampling.

    PubMed

    Li, Shanshan

    2017-04-15

    Prevalent sampling is frequently a convenient and economical sampling technique for the collection of time-to-event data and thus is commonly used in studies of the natural history of a disease. However, it is biased by design because it tends to recruit individuals with longer survival times. This paper considers estimation of time-dependent receiver operating characteristic curves when data are collected under prevalent sampling. To correct the sampling bias, we develop both nonparametric and semiparametric estimators using extended risk sets and the inverse probability weighting techniques. The proposed estimators are consistent and converge to Gaussian processes, while substantial bias may arise if standard estimators for right-censored data are used. To illustrate our method, we analyze data from an ovarian cancer study and estimate receiver operating characteristic curves that assess the accuracy of the composite markers in distinguishing subjects who died within 3-5 years from subjects who remained alive. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  19. Determination of total mercury in fillets of sport fishes collected from Folsom Reservoir, California, 2006

    USGS Publications Warehouse

    May, Thomas W.; Brumbaugh, William G.

    2007-01-01

    This report presents the results of a study by the U.S. Geological Survey, done in cooperation with the U.S. Bureau of Reclamation, to determine mercury concentrations in selected sport fishes from Folsom Reservoir in California. Fillets were collected from each fish sample, and after homogenization and lyophilization of fish fillets, mercury concentrations were determined with a direct mercury analyzer utilizing the process of thermal combustion-gold amalgamation atomic absorption spectroscopy. Mercury concentrations in fillets ranged from 0.031 to 0.20 micrograms per gram wet weight in rainbow trout (Oncorhynchus mykiss) samples and 0.071 to 0.16 micrograms per gram wet weight in bluegill (Lepomis macrochirus) samples. Mercury concentration was 0.98 microgram per gram wet weight in a single spotted bass (Micropterus punctulatus) sample, which was the only one in the sample set which exceeded the U.S. Environmental Protection Agency's fish consumption advisory of 0.30 microgram per gram wet weight.

  20. Instrumental neutron activation analysis for studying size-fractionated aerosols

    NASA Astrophysics Data System (ADS)

    Salma, Imre; Zemplén-Papp, Éva

    1999-10-01

    Instrumental neutron activation analysis (INAA) was utilized for studying aerosol samples collected into a coarse and a fine size fraction on Nuclepore polycarbonate membrane filters. As a result of the panoramic INAA, 49 elements were determined in an amount of about 200-400 μg of particulate matter by two irradiations and four γ-spectrometric measurements. The analytical calculations were performed by the absolute ( k0) standardization method. The calibration procedures, application protocol and the data evaluation process are described and discussed. They make it possible now to analyse a considerable number of samples, with assuring the quality of the results. As a means of demonstrating the system's analytical capabilities, the concentration ranges, median or mean atmospheric concentrations and detection limits are presented for an extensive series of aerosol samples collected within the framework of an urban air pollution study in Budapest. For most elements, the precision of the analysis was found to be beyond the uncertainty represented by the sampling techniques and sample variability.

  1. Baseline tests for arc melter vitrification of INEL buried wastes. Volume II: Baseline test data appendices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oden, L.L.; O`Conner, W.K.; Turner, P.C.

    1993-11-19

    This report presents field results and raw data from the Buried Waste Integrated Demonstration (BWID) Arc Melter Vitrification Project Phase 1 baseline test series conducted by the Idaho National Engineering Laboratory (INEL) in cooperation with the U.S. Bureau of Mines (USBM). The baseline test series was conducted using the electric arc melter facility at the USBM Albany Research Center in Albany, Oregon. Five different surrogate waste feed mixtures were tested that simulated thermally-oxidized, buried, TRU-contaminated, mixed wastes and soils present at the INEL. The USBM Arc Furnace Integrated Waste Processing Test Facility includes a continuous feed system, the arc meltingmore » furnace, an offgas control system, and utilities. The melter is a sealed, 3-phase alternating current (ac) furnace approximately 2 m high and 1.3 m wide. The furnace has a capacity of 1 metric ton of steel and can process as much as 1,500 lb/h of soil-type waste materials. The surrogate feed materials included five mixtures designed to simulate incinerated TRU-contaminated buried waste materials mixed with INEL soil. Process samples, melter system operations data and offgas composition data were obtained during the baseline tests to evaluate the melter performance and meet test objectives. Samples and data gathered during this program included (a) automatically and manually logged melter systems operations data, (b) process samples of slag, metal and fume solids, and (c) offgas composition, temperature, velocity, flowrate, moisture content, particulate loading and metals content. This report consists of 2 volumes: Volume I summarizes the baseline test operations. It includes an executive summary, system and facility description, review of the surrogate waste mixtures, and a description of the baseline test activities, measurements, and sample collection. Volume II contains the raw test data and sample analyses from samples collected during the baseline tests.« less

  2. Baseline tests for arc melter vitrification of INEL buried wastes. Volume 1: Facility description and summary data report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oden, L.L.; O`Connor, W.K.; Turner, P.C.

    1993-11-19

    This report presents field results and raw data from the Buried Waste Integrated Demonstration (BWID) Arc Melter Vitrification Project Phase 1 baseline test series conducted by the Idaho National Engineering Laboratory (INEL) in cooperation with the U.S. Bureau of Mines (USBM). The baseline test series was conducted using the electric arc melter facility at the USBM Albany Research Center in Albany, Oregon. Five different surrogate waste feed mixtures were tested that simulated thermally-oxidized, buried, TRU-contaminated, mixed wastes and soils present at the INEL. The USBM Arc Furnace Integrated Waste Processing Test Facility includes a continuous feed system, the arc meltingmore » furnace, an offgas control system, and utilities. The melter is a sealed, 3-phase alternating current (ac) furnace approximately 2 m high and 1.3 m wide. The furnace has a capacity of 1 metric ton of steel and can process as much as 1,500 lb/h of soil-type waste materials. The surrogate feed materials included five mixtures designed to simulate incinerated TRU-contaminated buried waste materials mixed with INEL soil. Process samples, melter system operations data and offgas composition data were obtained during the baseline tests to evaluate the melter performance and meet test objectives. Samples and data gathered during this program included (a) automatically and manually logged melter systems operations data, (b) process samples of slag, metal and fume solids, and (c) offgas composition, temperature, velocity, flowrate, moisture content, particulate loading and metals content. This report consists of 2 volumes: Volume I summarizes the baseline test operations. It includes an executive summary, system and facility description, review of the surrogate waste mixtures, and a description of the baseline test activities, measurements, and sample collection. Volume II contains the raw test data and sample analyses from samples collected during the baseline tests.« less

  3. Evaluation of counting methods for oceanic radium-228

    NASA Astrophysics Data System (ADS)

    Orr, James C.

    1988-07-01

    Measurement of open ocean 228Ra is difficult, typically requiring at least 200 L of seawater. The burden of collecting and processing these large-volume samples severely limits the widespread use of this promising tracer. To use smaller-volume samples, a more sensitive means of analysis is required. To seek out new and improved counting method(s), conventional 228Ra counting methods have been compared with some promising techniques which are currently used for other radionuclides. Of the conventional methods, α spectrometry possesses the highest efficiency (3-9%) and lowest background (0.0015 cpm), but it suffers from the need for complex chemical processing after sampling and the need to allow about 1 year for adequate ingrowth of 228Th granddaughter. The other two conventional counting methods measure the short-lived 228Ac daughter while it remains supported by 228Ra, thereby avoiding the complex sample processing and the long delay before counting. The first of these, high-resolution γ spectrometry, offers the simplest processing and an efficiency (4.8%) comparable to α spectrometry; yet its high background (0.16 cpm) and substantial equipment cost (˜30,000) limit its widespread use. The second no-wait method, β-γ coincidence spectrometry, also offers comparable efficiency (5.3%), but it possesses both lower background (0.0054 cpm) and lower initial cost (˜12,000). Three new (i.e., untried for 228Ra) techniques all seem to promise about a fivefold increase in efficiency over conventional methods. By employing liquid scintillation methods, both α spectrometry and β-γ coincidence spectrometry can improve their counter efficiency while retaining low background. The third new 228Ra counting method could be adapted from a technique which measures 224Ra by 220Rn emanation. After allowing for ingrowth and then counting for the 224Ra great-granddaughter, 228Ra could be back calculated, thereby yielding a method with high efficiency, where no sample processing is required. The efficiency and background of each of the three new methods have been estimated and are compared with those of the three methods currently employed to measure oceanic 228Ra. From efficiency and background, the relative figure of merit and the detection limit have been determined for each of the six counters. These data suggest that the new counting methods have the potential to measure most 228Ra samples with just 30 L of seawater, to better than 5% precision. Not only would this reduce the time, effort, and expense involved in sample collection, but 228Ra could then be measured on many small-volume samples (20-30 L) previously collected with only 226Ra in mind. By measuring 228Ra quantitatively on such small-volume samples, three analyses (large-volume 228Ra, large-volume 226Ra, and small-volume 226Ra) could be reduced to one, thereby dramatically improving analytical precision.

  4. Water Collection from Air Humidity in Bahrain

    NASA Astrophysics Data System (ADS)

    Dahman, Nidal A.; Al Juboori, Khalil J.; BuKamal, Eman A.; Ali, Fatima M.; AlSharooqi, Khadija K.; Al-Banna, Shaima A.

    2017-11-01

    The Kingdom of Bahrain falls geographically in one of the driest regions in the world. Conventional fresh surface water bodies, such as rivers and lakes, are nonexistent and for water consumption, Bahrain prominently relies on the desalination of sea water. This paper presents an ongoing project that is being pursued by a group of student and their advising professors to investigate the viability of extracting water from air humidity. Dehumidifiers have been utilized as water extraction devices. Those devices have been distributed on six areas that were selected based on a rigorous geospatial modeling of historical meteorological data. The areas fall in residential and industrial neighborhoods that are located in the main island and the island of Muharraq. Water samples have been collected three times every week since May of 2016 and the collection process will continue until May of 2017. The collected water samples have been analyzed against numerous variables individually and in combinations including: amount of water collected per hour versus geographical location, amount of water collected per hour versus meteorological factors, suitability of collected water for potable human consumption, detection of air pollution in the areas of collection and the economy of this method of water collection in comparison to other nonconventional methods. An overview of the completed analysis results is presented in this paper.

  5. Conceptualizing the therapist's role in therapy in psychosis.

    PubMed

    Dilks, Sarah; Tasker, Fiona; Wren, Bernadette

    2013-09-01

    This paper reports on a subset of findings from a wider ranging grounded theory analysis of therapy and recovery processes in psychosis. It describes therapist activities involved in maintaining an observational perspective during therapy and the links between these and other therapist activities. Grounded theory was used to examine the qualitative data collected. An initial sample of 19 taped therapy sessions and 23 interviews with psychologists and their clients was collected. This sample was extended through the collection of three further interviews with psychoanalytically aware psychologists. The data were analysed using grounded theory. A grounded theory model of therapy processes in psychosis was developed that conceptualized therapist actions as providing an observational scaffold to support the client's efforts in moving to new perspectives on their situation. Consistent with the understanding of the core therapy activity as a dialogical process, this set of therapist actions was understood as occurring alongside other therapist activities involved in managing emotion and building a relationship in therapy. The central activity of therapy in psychosis was understood as a dialogical process continuously negotiated between therapist and client in conversation and was conceptually summarized in the grounded theory as 'building bridges to observational perspectives'. However, the active and strategic efforts of psychologists to sustain the dialogue implied a particular assumption of responsibility for maintaining this process. In particular, therapists appeared to be 'working to maintain observational perspectives', 'managing emotion', and 'doing relationship' during the therapy conversation as part of the joint effort with clients to build bridges to new observational perspectives on distress and psychosis. © 2012 The British Psychological Society.

  6. Potential and Challenges in Collecting Social and Behavioral Data on Adolescent Alcohol Norms: Comparing Respondent-Driven Sampling and Web-Based Respondent-Driven Sampling

    PubMed Central

    Hildebrand, Janina; Burns, Sharyn; Zhao, Yun; Lobo, Roanna; Howat, Peter; Allsop, Steve

    2015-01-01

    Background Respondent-driven sampling (RDS) is a method successfully used to research hard-to-access populations. Few studies have explored the use of the Internet and social media with RDS, known as Web-based RDS (WebRDS). This study explored the use of combining both “traditional” RDS and WebRDS to examine the influences on adolescent alcohol use. Objective This paper reports on the recruitment processes and the challenges and enablers of both RDS and WebRDS. It details comparative recruitment data and provides a summary of the utility of both methods for recruiting adolescents to participate in an online survey investigating youth alcohol norms. Methods Process evaluation data collected from research staff throughout the study were used to assess the challenges and solutions of RDS and WebRDS. Pearson chi-square test (Fisher’s exact test if applicable) was used to compare the differences in sociodemographics and drinking behavior between data collected by RDS and WebRDS. Results Of the total sample (N=1012), 232 adolescents were recruited by RDS and 780 by WebRDS. A significantly larger proportion of Aboriginal or Torres Strait Islander (P<.001) participants who spoke English as their main language at home (P=.03), and of middle and lower socioeconomic status (P<.001) was found in the RDS sample. The RDS sample was also found to have a higher occurrence of past 7-day drinking (P<.001) and past 7-day risky drinking (P=.004). No significant differences in gender, age, past month alcohol use, and lifetime alcohol use were observed between the RDS and WebRDS samples. This study revealed RDS and WebRDS used similar lengths of chains for recruiting participants; however, WebRDS conducted a faster rate of recruitment at a lower average cost per participant compared to RDS. Conclusions Using WebRDS resulted in significant improvements in the recruitment rate and was a more effective and efficient use of resources than the traditional RDS method. However, WebRDS resulted in partially different sample characteristics to traditional RDS. This potential effect should be considered when selecting the most appropriate data collection method. PMID:26704736

  7. Data Validation Package November 2015 Groundwater and Surface Water Sampling at the Old and New Rifle, Colorado, Processing Sites February 2016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bush, Richard; Lemke, Peter

    Water samples were collected from 36 locations at New Rifle and Old Rifle, Colorado, Processing Sites. Duplicate samples were collected from New Rifle locations 0659 and 0855, and Old Rifle location 0304. One equipment blank was collected after decontamination of non-dedicated equipment used to collect one surface water sample. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). New Rifle Site Samples were collected at the New Rifle site from 16 monitoring wells and 7 surface locations in compliance with the December 2008more » Groundwater Compliance Action Plan [GCAP] for the New Rifle, Colorado, Processing Site (LMS/RFN/S01920), with one exception: New Rifle location 0635 could not be sampled because it was inaccessible; a fence installed by the Colorado Department of Transportation prevents access to this location. DOE is currently negotiating access with the Colorado Department of Transportation. Analytes measured at the New Rifle site included contaminants of concern (COCs) (arsenic, molybdenum, nitrate + nitrite as nitrogen, selenium, uranium, and vanadium) ammonia as nitrogen, major cations, and major anions. Field measurements of total alkalinity, oxidation- reduction potential, pH, specific conductance, turbidity, and temperature were made at each location, and the water level was measured at each sampled well. A proposed alternate concentration limit (ACL) for vanadium of 50 milligrams per liter (mg/L), specific to the compliance (POC) wells (RFN-0217, -0659, -0664, and -0669) is included in the New Rifle GCAP. Vanadium concentrations in the POC wells were below the proposed ACL as shown in the time-concentration graphs in the Data Presentation section (Attachment 2). Time-concentration graphs from all other locations sampled are also included in Attachment 2. Sampling location RFN-0195 was misidentified for the June/August 2014 and November 2014 sampling events. (Well RFN-0609 was inadvertently sampled instead of RFN-0195 in 2014.) The results for RFN-0195 have been corrected, and are included in associated time-concentration graphs for this location. Recent results for RFN-0195 are consistent with established trends with the possible exception of vanadium. The most recent result for vanadium showed an increase over recent values. Vanadium concentrations at RFN-0195 and other locations will continue to be evaluated in the future to determine the potential for deviations from established trends. The surface water locations were sampled to monitor the impact of groundwater discharge. COC concentrations at Colorado River surface water locations RFN-0324 and RFN-0326, downgradient of the site, remained low and were consistent with historical results, as shown in the time-concentration graphs. COC concentrations did not indicate there are any impacts related to groundwater discharge to the river. In many cases, elevated COC concentrations at the New Rifle site pond locations were observed, as shown in the time-versus concentration graphs. As noted in the GCAP, this indicates impacts from groundwater discharge to the ponds. Old Rifle Site Samples were collected at the Old Rifle site from eight monitoring wells and five surface locations in compliance with the December 2001 Groundwater Compliance Action Plan for the Old Rifle, Colorado, UMTRA Project Site (GJ0-2000-177-TAR). Analytes measured at the Old Rifle site included COCs (selenium, uranium, and vanadium), major cations, and major anions. Field measurements of total alkalinity, oxidation-reduction potential, pH, specific conductance, turbidity, temperature, were made at each location, and the water level was measured at each sampled well. The monitoring strategy described in the GCAP is designed to determine progress of the natural flushing process in meeting compliance standards for site COCs. Standards for selenium and vanadium are the proposed ACLs of0.05 mg/L and 1.0 mg/L, respectively. For uranium the cleanup goal is the UMTRA standard of 0.044 mg/L or background, whichever is higher. As shown in the time concentration graphs, the uranium concentration exceeds the cleanup goal at groundwater monitoring locations RF0-0304, -0305, -0310, -0655, and -0656. The surface water locations were sampled to monitor the impact of groundwater discharge at Colorado River surface water locations adjacent to (RF0-0396) and downgradient of the site (RF0-0741). COC concentrations remain low and consistent with historical concentrations as shown in the time-concentration graphs (Attachment 2), which indicate no impacts from groundwater discharge to the river.« less

  8. National Geological and Geophysical Data Preservation Program: Successes and Lessons Learned

    NASA Astrophysics Data System (ADS)

    Adrian, B. M.

    2014-12-01

    The United States Geological Survey (USGS) is widely recognized in the earth science community as possessing extensive collections of geologic and geophysical materials gathered by its research personnel. Since the USGS was established in 1879, hundreds of thousands of samples have been gathered in collections that range from localized, geographically-based assemblages to ones that are national or international in scope. These materials include, but are not limited to, rock and mineral specimens; fossils; drill cores and cuttings; geochemical standards; and soil, sediment, and geochemical samples. The USGS National Geological and Geophysical Data Preservation Program (NGGDPP) was established with the passage of the Energy Policy Act of 2005. Since its implementation, the USGS NGGDPP has taken an active role in providing opportunities to inventory, archive and preserve geologic and geophysical samples, and to make these samples and ancillary data discoverable on the Internet. Preserving endangered geoscience collections is more cost effective than recollecting this information. Preserving these collections, however, is only one part of the process - there also needs to be a means to facilitate open discovery and access to the physical objects and the ancillary digital records. The NGGDPP has celebrated successes such as the development of the USGS Geologic Collections Management System (GCMS), a master catalog and collections management plan, and the implementation and advancement of the National Digital Catalog, a digital inventory and catalog of geological and geophysical data and collections held by the USGS and State geological surveys. Over this period of time there has been many lessons learned. With the successes and lessons learned, NGGDPP is poised to take on challenges the future may bring.

  9. The NCBI BioCollections Database

    PubMed Central

    Sharma, Shobha; Ciufo, Stacy; Starchenko, Elena; Darji, Dakshesh; Chlumsky, Larry; Karsch-Mizrachi, Ilene

    2018-01-01

    Abstract The rapidly growing set of GenBank submissions includes sequences that are derived from vouchered specimens. These are associated with culture collections, museums, herbaria and other natural history collections, both living and preserved. Correct identification of the specimens studied, along with a method to associate the sample with its institution, is critical to the outcome of related studies and analyses. The National Center for Biotechnology Information BioCollections Database was established to allow the association of specimen vouchers and related sequence records to their home institutions. This process also allows cross-linking from the home institution for quick identification of all records originating from each collection. Database URL: https://www.ncbi.nlm.nih.gov/biocollections PMID:29688360

  10. Reduction in Nontuberculous Mycobacteria at a Tuberculosis Hospital Following a Quality Assurance Intervention

    PubMed Central

    Kizilbash, Quratulain; Jost, Kenneth; Armitige, Lisa; Griffith, David E; Dunbar, Denise; Seaworth, Barbara

    2017-01-01

    Abstract Background Non tuberculous mycobacteria (NTM) are widely distributed in soil and water. NTM/Mycobacterium tuberculosis complex (MTBC) mixes may yield positive AFB smears falsely attributed to tuberculosis (TB) and false-resistance profiles for TB due to contaminated diagnostic samples. This as well as isolation of NTM may pose diagnostic and management problems. Texas Center for Infectious Disease (TCID) is a hospital for patients with confirmed TB. After a cluster of isolates of Mycobacterium gordonae was identified, a quality assurance review found inadequate protocols which included eating and drinking prior to collection. Changes made to the sputum collection protocol included reeducation of respiratory therapists and a sterile saline rinse intervention prior to sputum collection. Methods All sputa collected for AFB culture from diagnosed TB patients at TCID from January 1st, 2014 to December 31st, 2014 prior to the intervention and from August 1st, 2016 to January 31st, 2017, the 6 months following the quality assurance intervention were included. Sputum samples were processed at the Texas Department of State and Health Services (DSHS) Laboratory. Results A total of 1,853 sputum samples were processed; 1,288 from 2014 and 565 following the intervention. NTM decreased from 56 (4.3%) to 7 (1.2%) after the quality assurance intervention was instituted for a NTM decrease of 75.0%. M. gordonae decreased by 78.6%. No patients had evidence of NTM disease. Conclusion A breach in sputum collection protocols at TCID accounted for the increase in NTM isolation in 2014, half of which were M. gordonae. The reeducation of respiratory therapy staff and initiation of sterile saline rinse prior to sputum collection resulted in a significant reduction in the overall NTM rate. M. gordonae was isolated only three times following the intervention. At TCID, a location where tap water and bottled water contains NTM, drinking these prior to sputum collection possibly contributed to the cluster for NTM, especially M. gordonae. We recommend rinsing the mouth with sterile saline or water prior to sputum collection to decrease isolation of rarely pathogenic NTM. Disclosures All authors: No reported disclosures.

  11. Prevalence of multi drug antimicrobial resistance in isolated from high-risk stocker cattle at arrival and two weeks after processing.

    PubMed

    Snyder, E; Credille, B; Berghaus, R; Giguère, S

    2017-03-01

    Bovine respiratory disease (BRD) is the leading cause of morbidity and mortality in North American beef cattle. () is the bacterial pathogen most frequently isolated from cattle with BRD and the prevalence of antimicrobial resistance in this pathogen has been increasing. Administration of antimicrobials to prevent BRD is commonplace in stocker cattle, but the impact of this practice on emergence of resistance in is unknown. High risk, sale barn origin bull and steer calves ( = 169) were transported to a stocker facility in central Georgia and sampled via deep nasopharyngeal swab (NPS) at arrival processing. All calves received the macrolide antimicrobial tulathromycin (2.5 mg/kg subcutaneously) at arrival processing. A second NPS was collected from each calf 10 to 14 d after arrival. The occasional calves diagnosed and treated for BRD prior to 10 to 14 d were swabbed and cultured prior to treatment. Swabs were submitted for culture and antimicrobial susceptibility testing using the Kirby-Bauer disk diffusion method. Of the 169 cattle enrolled, 27 (16.0%) were culture positive for at arrival processing and of these, a multi-drug resistant (MDR) strain of was detected in 1 (3.7%). In contrast, 123 (72.8%) cattle were culture positive for at second sampling and of these, a MDR strain of was detected in 122 (99.2%). The proportions of cattle culture positive for and positive for MDR at arrival processing and at second sampling were significantly different ( < 0.001). At the level of the individual bacterial isolate, 366 individual isolates were collected from the calves at the time of the second sampling. Of these isolates, 361 (98.6%) were intermediate or resistant to all macrolides tested (tilmicosin, gamithromycin, tulathromycin) and the fluoroquinolone enrofloxacin. In addition, 254 isolates (69.4%) were intermediate or resistant to florfenicol and 4 (1.1%) were intermediate or resistant to ceftiofur. There was a significant difference in the proportion of isolates resistant to all of the drug classes except cephalosporins at arrival processing versus second sampling ( < 0.001). Our results show that there was an increase in the proportion of calves positive for from arrival processing to second sampling, and that there was an increase in the proportion of calves that had MDR strains of detected from arrival processing to second sampling. More research is needed to understand the role of metaphylaxis on MDR in and the impact of MDR on morbidity and mortality in stocker cattle.

  12. Planned Variation in Preanalytical Conditions to Evaluate Biospecimen Stability in the National Children’s Study (NCS)

    PubMed Central

    Mechanic, Leah; Mendez, Armando; Merrill, Lori; Rogers, John; Layton, Marnie; Todd, Deborah; Varanasi, Arti; O’Brien, Barbara; Meyer, William A.; Zhang, Ming; Schleicher, Rosemary L.; Moye, Jack

    2014-01-01

    BACKGROUND Preanalytical conditions encountered during collection, processing, and storage of biospecimens may influence laboratory results. The National Children’s Study (NCS) is a planned prospective cohort study of 100,000 families to examine the influence of a wide variety of exposures on child health. In developing biospecimen collection, processing, and storage procedures for the NCS, we identified several analytes of different biochemical categories for which it was unclear to what extent deviations from NCS procedures could influence measurement results. METHODS A pilot study was performed to examine effects of preanalytic sample handling conditions (delays in centrifugation, freezing delays, delays in separation from cells, additive delay, and tube type) on concentrations of eight different analytes. 2,825 measurements were made to assess 15 unique combinations of analyte and handling conditions in blood collected from 151 women of childbearing age (≥20 individuals per handling condition). RESULTS The majority of analytes were stable under the conditions evaluated. However, levels of plasma interleukin-6 and serum insulin were decreased in response to sample centrifugation delays of up to 5.5 hours post collection (P<0.0001). In addition, delays in freezing centrifuged plasma samples (comparing 24, 48 and 72 hours to immediate freezing) resulted in increased levels of adrenocorticotropic hormone (P=0.0014). CONCLUSIONS Determining stability of proposed analytes in response to preanalytical conditions and handling helps to ensure high-quality specimens for study now and in the future. The results inform development of procedures, plans for measurement of analytes, and interpretation of laboratory results. PMID:23924524

  13. Oxytocin Levels in Community-Collected Saliva Samples Transported by Dry Versus Wet Ice.

    PubMed

    Howland, Lois C; Pickler, Rita H; Sullenbarger, Brent A; Connelly, Cynthia D

    2018-01-01

    Oxytocin (OT), a neuropeptide produced primarily in the hypothalamus, is associated with both critical physiological and psychological processes, particularly stress and feelings of affiliation. Increasingly, researchers are seeking ways to reliably incorporate OT as an outcome biomarker in clinical research. Previously, OT levels were measured in plasma or urine. Recently, researchers have measured this biomarker in saliva, particularly when conducting research in clinical and community settings. In spite of increased interest in the use of salivary OT in clinical research, procedures for handling, transport, and analysis of specimens vary. It is not known if significant OT protein degradation occurs if samples are initially transported on wet ice before being frozen. The aim of this study is to evaluate the effect of transport media (wet vs. dry ice) on OT levels derived from saliva collected from 12 postpartum women residing in the community. Saliva collected from each participant was divided between two microcentrifuge tubes (MIDSCI, Valley Park, MO), one placed on wet ice and one on dry ice for transport from the participant's home to the laboratory freezer. Time from collection to storage freezer was recorded. Laboratory personnel, blinded to method of transport, batch processed the samples. No significant differences in OT levels were found by transport method. Despite large interperson variations in OT levels, there were negligible intraperson variations. Although further research is required to identify factors (including transport time) related to interperson variation, this study supports the use of wet ice as a means of transporting salivary OT specimens in community-based research.

  14. An Interdisciplinary Method for the Visualization of Novel High-Resolution Precision Photography and Micro-XCT Data Sets of NASA's Apollo Lunar Samples and Antarctic Meteorite Samples to Create Combined Research-Grade 3D Virtual Samples for the Benefit of Astromaterials Collections Conservation, Curation, Scientific Research and Education

    NASA Technical Reports Server (NTRS)

    Blumenfeld, E. H.; Evans, C. A.; Oshel, E. R.; Liddle, D. A.; Beaulieu, K.; Zeigler, R. A.; Hanna, R. D.; Ketcham, R. A.

    2016-01-01

    New technologies make possible the advancement of documentation and visualization practices that can enhance conservation and curation protocols for NASA's Astromaterials Collections. With increasing demands for accessibility to updated comprehensive data, and with new sample return missions on the horizon, it is of primary importance to develop new standards for contemporary documentation and visualization methodologies. Our interdisciplinary team has expertise in the fields of heritage conservation practices, professional photography, photogrammetry, imaging science, application engineering, data curation, geoscience, and astromaterials curation. Our objective is to create virtual 3D reconstructions of Apollo Lunar and Antarctic Meteorite samples that are a fusion of two state-of-the-art data sets: the interior view of the sample by collecting Micro-XCT data and the exterior view of the sample by collecting high-resolution precision photography data. These new data provide researchers an information-rich visualization of both compositional and textural information prior to any physical sub-sampling. Since January 2013 we have developed a process that resulted in the successful creation of the first image-based 3D reconstruction of an Apollo Lunar Sample correlated to a 3D reconstruction of the same sample's Micro- XCT data, illustrating that this technique is both operationally possible and functionally beneficial. In May of 2016 we began a 3-year research period during which we aim to produce Virtual Astromaterials Samples for 60 high-priority Apollo Lunar and Antarctic Meteorite samples and serve them on NASA's Astromaterials Acquisition and Curation website. Our research demonstrates that research-grade Virtual Astromaterials Samples are beneficial in preserving for posterity a precise 3D reconstruction of the sample prior to sub-sampling, which greatly improves documentation practices, provides unique and novel visualization of the sample's interior and exterior features, offers scientists a preliminary research tool for targeted sub-sample requests, and additionally is a visually engaging interactive tool for bringing astromaterials science to the public.

  15. An Interdisciplinary Method for the Visualization of Novel High-Resolution Precision Photography and Micro-XCT Data Sets of NASA's Apollo Lunar Samples and Antarctic Meteorite Samples to Create Combined Research-Grade 3D Virtual Samples for the Benefit of Astromaterials Collections Conservation, Curation, Scientific Research and Education

    NASA Astrophysics Data System (ADS)

    Blumenfeld, E. H.; Evans, C. A.; Zeigler, R. A.; Righter, K.; Beaulieu, K. R.; Oshel, E. R.; Liddle, D. A.; Hanna, R.; Ketcham, R. A.; Todd, N. S.

    2016-12-01

    New technologies make possible the advancement of documentation and visualization practices that can enhance conservation and curation protocols for NASA's Astromaterials Collections. With increasing demands for accessibility to updated comprehensive data, and with new sample return missions on the horizon, it is of primary importance to develop new standards for contemporary documentation and visualization methodologies. Our interdisciplinary team has expertise in the fields of heritage conservation practices, professional photography, photogrammetry, imaging science, application engineering, data curation, geoscience, and astromaterials curation. Our objective is to create virtual 3D reconstructions of Apollo Lunar and Antarctic Meteorite samples that are a fusion of two state-of-the-art data sets: the interior view of the sample by collecting Micro-XCT data and the exterior view of the sample by collecting high-resolution precision photography data. These new data provide researchers an information-rich visualization of both compositional and textural information prior to any physical sub-sampling. Since January 2013 we have developed a process that resulted in the successful creation of the first image-based 3D reconstruction of an Apollo Lunar Sample correlated to a 3D reconstruction of the same sample's Micro-XCT data, illustrating that this technique is both operationally possible and functionally beneficial. In May of 2016 we began a 3-year research period during which we aim to produce Virtual Astromaterials Samples for 60 high-priority Apollo Lunar and Antarctic Meteorite samples and serve them on NASA's Astromaterials Acquisition and Curation website. Our research demonstrates that research-grade Virtual Astromaterials Samples are beneficial in preserving for posterity a precise 3D reconstruction of the sample prior to sub-sampling, which greatly improves documentation practices, provides unique and novel visualization of the sample's interior and exterior features, offers scientists a preliminary research tool for targeted sub-sample requests, and additionally is a visually engaging interactive tool for bringing astromaterials science to the public.

  16. Surface roughness and runoff

    NASA Astrophysics Data System (ADS)

    Szabó, Judit Alexandra; Szabó, Boglárka; Centeri, Csaba; Józsa, Sándor; Szalai, Zoltán; Jakab, Gergely

    2017-04-01

    Soil surface conditions changes dynamically during a precipitation event. The changes involve compaction, aggregate detachment and of course transportation by runoff or drop erosion. Those processes together have an effect on the transport process of the soil particles and aggregates, and influences the roughness of the soil surface as well. How does surface roughness have an effect on the aggregate and particle size distribution of the sediment? How does the sediment connectivity change from precipitation event to precipitation event? Beside the previous questions on of the main aim of the present research is to apply rainfall simulators for the built-up of a complex approach, rather than to concentrate only on one of two factors. Hence four types of sample were collected during the simulation experiment sequences: 1) photos were taken about the surface before and after the rain, in order to build digital surface models; 2) all the runoff and eroded sediment was collected; 3) soil loss due to drop erosion was also sampled separately; and 4) undisturbed crust samples were collected for thin section analyses. Though the runoff ratio was smaller than what, the preliminary results suggest that the sediment connectivity covered bigger area on crusty surface, than on a rough one. These ambiguous data may be connected to the soil crust development. J. A. Szabó wish to acknowledge the support of NTP-NFTÖ-16-0203. G. Jakab wish to acknowledge the support of János Bolyai Fellowship.

  17. Detection of Legionella, L. pneumophila and Mycobacterium Avium Complex (MAC) along Potable Water Distribution Pipelines

    PubMed Central

    Whiley, Harriet; Keegan, Alexandra; Fallowfield, Howard; Bentham, Richard

    2014-01-01

    Inhalation of potable water presents a potential route of exposure to opportunistic pathogens and hence warrants significant public health concern. This study used qPCR to detect opportunistic pathogens Legionella spp., L. pneumophila and MAC at multiple points along two potable water distribution pipelines. One used chlorine disinfection and the other chloramine disinfection. Samples were collected four times over the year to provide seasonal variation and the chlorine or chloramine residual was measured during collection. Legionella spp., L. pneumophila and MAC were detected in both distribution systems throughout the year and were all detected at a maximum concentration of 103 copies/mL in the chlorine disinfected system and 106, 103 and 104 copies/mL respectively in the chloramine disinfected system. The concentrations of these opportunistic pathogens were primarily controlled throughout the distribution network through the maintenance of disinfection residuals. At a dead-end and when the disinfection residual was not maintained significant (p < 0.05) increases in concentration were observed when compared to the concentration measured closest to the processing plant in the same pipeline and sampling period. Total coliforms were not present in any water sample collected. This study demonstrates the ability of Legionella spp., L. pneumophila and MAC to survive the potable water disinfection process and highlights the need for greater measures to control these organisms along the distribution pipeline and at point of use. PMID:25046636

  18. Human Milk Fatty Acid Composition: Comparison of Novel Dried Milk Spot Versus Standard Liquid Extraction Methods.

    PubMed

    Rudolph, Michael C; Young, Bridget E; Jackson, Kristina Harris; Krebs, Nancy F; Harris, William S; MacLean, Paul S

    2016-12-01

    Accurate assessment of the long chain polyunsaturated fatty acid (LC-PUFA) content of human milk (HM) provides a powerful means to evaluate the FA nutrient status of breastfed infants. The conventional standard for FA composition analysis of HM is liquid extraction, trans-methylation, and analyte detection resolved by gas chromatography. This standard approach requires fresh or frozen samples, storage in deep freeze, organic solvents, and specialized equipment in processing and analysis. Further, HM collection is often impractical for many studies in the free living environment, particularly for studies in developing countries. In the present study, we compare a novel and more practical approach to sample collection and processing that involves the spotting and drying ~50 μL of HM on a specialized paper stored and transported at ambient temperatures until analysis. Deming regression indicated the two methods aligned very well for all LC-PUFA and the abundant HM FA. Additionally, strong correlations (r > 0.85) were observed for DHA, ARA, EPA, linoleic (LA), and alpha-linolenic acids (ALA), which are of particular interest to the health of the developing infant. Taken together, our data suggest this more practical and inexpensive method of collection, storage, and transport of HM milk samples could dramatically facilitate studies of HM, as well as understanding its lipid composition influences on human health and development.

  19. Detection of Legionella, L. pneumophila and Mycobacterium avium complex (MAC) along potable water distribution pipelines.

    PubMed

    Whiley, Harriet; Keegan, Alexandra; Fallowfield, Howard; Bentham, Richard

    2014-07-18

    Inhalation of potable water presents a potential route of exposure to opportunistic pathogens and hence warrants significant public health concern. This study used qPCR to detect opportunistic pathogens Legionella spp., L. pneumophila and MAC at multiple points along two potable water distribution pipelines. One used chlorine disinfection and the other chloramine disinfection. Samples were collected four times over the year to provide seasonal variation and the chlorine or chloramine residual was measured during collection. Legionella spp., L. pneumophila and MAC were detected in both distribution systems throughout the year and were all detected at a maximum concentration of 103 copies/mL in the chlorine disinfected system and 106, 103 and 104 copies/mL respectively in the chloramine disinfected system. The concentrations of these opportunistic pathogens were primarily controlled throughout the distribution network through the maintenance of disinfection residuals. At a dead-end and when the disinfection residual was not maintained significant (p < 0.05) increases in concentration were observed when compared to the concentration measured closest to the processing plant in the same pipeline and sampling period. Total coliforms were not present in any water sample collected. This study demonstrates the ability of Legionella spp., L. pneumophila and MAC to survive the potable water disinfection process and highlights the need for greater measures to control these organisms along the distribution pipeline and at point of use.

  20. Exposing USGS sample collections for broader discovery and access: collaboration between ScienceBase, IEDA:SESAR, and Paleobiology Database

    NASA Astrophysics Data System (ADS)

    Hsu, L.; Bristol, S.; Lehnert, K. A.; Arko, R. A.; Peters, S. E.; Uhen, M. D.; Song, L.

    2014-12-01

    The U.S. Geological Survey (USGS) is an exemplar of the need for improved cyberinfrastructure for its vast holdings of invaluable physical geoscience data. Millions of discrete paleobiological and geological specimens lie in USGS warehouses and at the Smithsonian Institution. These specimens serve as the basis for many geologic maps and geochemical databases, and are a potential treasure trove of new scientific knowledge. The extent of this treasure is virtually unknown and inaccessible outside a small group of paleogeoscientists and geochemists. A team from the USGS, the Integrated Earth Data Applications (IEDA) facility, and the Paleobiology Database (PBDB) are working to expose information on paleontological and geochemical specimens for discovery by scientists and citizens. This project uses existing infrastructure of the System for Earth Sample Registration (SESAR) and PBDB, which already contains much of the fundamental data schemas that are necessary to accommodate USGS records. The project is also developing a new Linked Data interface for the USGS National Geochemical Database (NGDB). The International Geo Sample Number (IGSN) is the identifier that links samples between all systems. For paleontological specimens, SESAR and PBDB will be the primary repositories for USGS records, with a data syncing process to archive records within the USGS ScienceBase system. The process began with mapping the metadata fields necessary for USGS collections to the existing SESAR and PBDB data structures, while aligning them with the Observations & Measurements and Darwin Core standards. New functionality needed in SESAR included links to a USGS locality registry, fossil classifications, a spatial qualifier attribution for samples with sensitive locations, and acknowledgement of data and metadata licensing. The team is developing a harvesting mechanism to periodically transfer USGS records from within PBDB and SESAR to ScienceBase. For the NGDB, the samples are being registered with IGSNs in SESAR and the geochemical data are being published as Linked Data. This system allows the USGS collections to benefit from disciplinary and institutional strengths of the participating resources, while simultaneously increasing the discovery, accessibility, and citation of USGS physical collection holdings.

Top