Sample records for sample collection techniques

  1. Changes in sample collection and analytical techniques and effects on retrospective comparability of low-level concentrations of trace elements in ground water

    USGS Publications Warehouse

    Ivahnenko, T.; Szabo, Z.; Gibs, J.

    2001-01-01

    Ground-water sampling techniques were modified to reduce random low-level contamination during collection of filtered water samples for determination of trace-element concentrations. The modified sampling techniques were first used in New Jersey by the US Geological Survey in 1994 along with inductively coupled plasma-mass spectrometry (ICP-MS) analysis to determine the concentrations of 18 trace elements at the one microgram-per-liter (μg/L) level in the oxic water of the unconfined sand and gravel Kirkwood-Cohansey aquifer system. The revised technique tested included a combination of the following: collection of samples (1) with flow rates of about 2L per minute, (2) through acid-washed single-use disposable tubing and (3) a single-use disposable 0.45-μm pore size capsule filter, (4) contained within portable glove boxes, (5) in a dedicated clean sampling van, (6) only after turbidity stabilized at values less than 2 nephelometric turbidity units (NTU), when possible. Quality-assurance data, obtained from equipment blanks and split samples, indicated that trace element concentrations, with the exception of iron, chromium, aluminum, and zinc, measured in the samples collected in 1994 were not subject to random contamination at 1μg/L.Results from samples collected in 1994 were compared to those from samples collected in 1991 from the same 12 PVC-cased observation wells using the available sampling and analytical techniques at that time. Concentrations of copper, lead, manganese and zinc were statistically significantly lower in samples collected in 1994 than in 1991. Sampling techniques used in 1994 likely provided trace-element data that represented concentrations in the aquifer with less bias than data from 1991 when samples were collected without the same degree of attention to sample handling.

  2. ESDA®-Lite collection of DNA from latent fingerprints on documents.

    PubMed

    Plaza, Dane T; Mealy, Jamia L; Lane, J Nicholas; Parsons, M Neal; Bathrick, Abigail S; Slack, Donia P

    2015-05-01

    The ability to detect and non-destructively collect biological samples for DNA processing would benefit the forensic community by preserving the physical integrity of evidentiary items for more thorough evaluations by other forensic disciplines. The Electrostatic Detection Apparatus (ESDA®) was systemically evaluated for its ability to non-destructively collect DNA from latent fingerprints deposited on various paper substrates for short tandem repeat (STR) DNA profiling. Fingerprints were deposited on a variety of paper substrates that included resume paper, cotton paper, magazine paper, currency, copy paper, and newspaper. Three DNA collection techniques were performed: ESDA collection, dry swabbing, and substrate cutting. Efficacy of each collection technique was evaluated by the quantity of DNA present in each sample and the percent profile generated by each sample. Both the ESDA and dry swabbing non-destructive sampling techniques outperformed the destructive methodology of substrate cutting. A greater number of full profiles were generated from samples collected with the non-destructive dry swabbing collection technique than were generated from samples collected with the ESDA; however, the ESDA also allowed the user to visualize the area of interest while non-destructively collecting the biological material. The ability to visualize the biological material made sampling straightforward and eliminated the need for numerous, random swabbings/cuttings. Based on these results, the evaluated non-destructive ESDA collection technique has great potential for real-world forensic implementation. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Clinical forensic sample collection techniques following consensual intercourse in volunteers - cervical canal brush compared to conventional swabs.

    PubMed

    Joki-Erkkilä, Minna; Tuomisto, Sari; Seppänen, Mervi; Huhtala, Heini; Ahola, Arja; Rainio, Juha; Karhunen, Pekka J

    2014-10-01

    The purpose of the research was to evaluate gynecological evidence collection techniques; the benefit of cervical canal brush sample compared to vaginal fornix and cervical swab samples and the time frame for detecting Y-chromosomal material QiAmp DNA Mini Kit(®) and Quantifiler Y Human Male DNA Quantification Kit(®) in adult volunteers following consensual intercourse. Eighty-four adult female volunteers following consensual intercourse were recruited for the study. By combining all sample collecting techniques, 81.0% of the volunteers were Y-DNA positive. Up to 60 h the conventional swab sampling techniques detected more Y-DNA positive samples when compared to the brush technique. However, after 60 h, the cervical canal brush sample technique showed its benefit by detecting 27.3% (6/22) of Y-DNA positive samples, which were Y-DNA negative in both conventional swab sampling techniques. By combining swab and brush techniques, 75% of the volunteers were still Y-DNA positive in 72-144 post-coital hours. The rate of measurable Y-DNA decreased approximately 3% per hour. Despite reported consensual intercourse, 6.8% (3/44) of volunteers were Y-DNA negative within 48 h. Y-DNA was not detected after 144 post-coital hours (6 days). In conclusion, the brush as a forensic evidence collection method may provide additional biological trace evidence from the cervical canal, although the best biological trace evidence collection can be obtained by combining all three sampling techniques. The time frame for gynecological forensic evidence sample collection should be considered to be at least a week if sexual violence is suspected. Copyright © 2014 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  4. A Feasibility Study of the Collection of Unscheduled Maintenance Data Using Statistical Sampling Techniques.

    DTIC Science & Technology

    1985-09-01

    TECHNIQUES THESIS Robert A. Heinlein Captain, USAF AFIT/GLM/LSM/855-32.- _ DTIC MU’noN ’ST.,TEMENT A A-ZELECTE Approved lt public teleo*I Al \\ Z #&N0V21...343" A FEASIBILITY STUDY OF THE COLLECTION OF UNSCHEDULED MAINTENANCE DATA USING STrATISTICAL SAMPLING TECHNIQUES THESIS L .9 Robe-t A. Heinlein...a AFIT/GLM/LSM/85S-32 A FEASIBILITY STUDY OF THE COLLECTION OF UNSCHEDULED MAINTENANCE DATA USING STATISTICAL SAMPLING TECHNIQUES THESIS

  5. Comparison of dialysis membrane diffusion samplers and two purging methods in bedrock wells

    USGS Publications Warehouse

    Imbrigiotta, T.E.; Ehlke, T.A.; Lacombe, P.J.; Dale, J.M.; ,

    2002-01-01

    Collection of ground-water samples from bedrock wells using low-flow purging techniques is problematic because of the random spacing, variable hydraulic conductivity, and variable contamination of contributing fractures in each well's open interval. To test alternatives to this purging method, a field comparison of three ground-water-sampling techniques was conducted on wells in fractured bedrock at a site contaminated primarily with volatile organic compounds. Constituent concentrations in samples collected with a diffusion sampler constructed from dialysis membrane material were compared to those in samples collected from the same wells with a standard low-flow purging technique and a hybrid (high-flow/low-flow) purging technique. Concentrations of trichloroethene, cis-1,2-dichloroethene, vinyl chloride, calcium, chloride, and alkalinity agreed well among samples collected with all three techniques in 9 of the 10 wells tested. Iron concentrations varied more than those of the other parameters, but their pattern of variation was not consistent. Overall, the results of nonparametric analysis of variance testing on the nine wells sampled twice showed no statistically significant difference at the 95-percent confidence level among the concentrations of volatile organic compounds or inorganic constituents recovered by use of any of the three sampling techniques.

  6. Evaluation of pyramid training as a method to increase diagnostic sampling capacity during an emergency veterinary response to a swine disease outbreak.

    PubMed

    Canon, Abbey J; Lauterbach, Nicholas; Bates, Jessica; Skoland, Kristin; Thomas, Paul; Ellingson, Josh; Ruston, Chelsea; Breuer, Mary; Gerardy, Kimberlee; Hershberger, Nicole; Hayman, Kristen; Buckley, Alexis; Holtkamp, Derald; Karriker, Locke

    2017-06-15

    OBJECTIVE To develop and evaluate a pyramid training method for teaching techniques for collection of diagnostic samples from swine. DESIGN Experimental trial. SAMPLE 45 veterinary students. PROCEDURES Participants went through a preinstruction assessment to determine their familiarity with the equipment needed and techniques used to collect samples of blood, nasal secretions, feces, and oral fluid from pigs. Participants were then shown a series of videos illustrating the correct equipment and techniques for collecting samples and were provided hands-on pyramid-based instruction wherein a single swine veterinarian trained 2 or 3 participants on each of the techniques and each of those participants, in turn, trained additional participants. Additional assessments were performed after the instruction was completed. RESULTS Following the instruction phase, percentages of participants able to collect adequate samples of blood, nasal secretions, feces, and oral fluid increased, as did scores on a written quiz assessing participants' ability to identify the correct equipment, positioning, and procedures for collection of samples. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that the pyramid training method may be a feasible way to rapidly increase diagnostic sampling capacity during an emergency veterinary response to a swine disease outbreak.

  7. Examining Returned Samples in their Collection Tubes Using Synchrotron Radiation-Based Techniques

    NASA Astrophysics Data System (ADS)

    Schoonen, M. A.; Hurowitz, J. A.; Thieme, J.; Dooryhee, E.; Fogelqvist, E.; Gregerson, J.; Farley, K. A.; Sherman, S.; Hill, J.

    2018-04-01

    Synchrotron radiation-based techniques can be leveraged for triaging and analysis of returned samples before unsealing collection tubes. Proof-of-concept measurements conducted at Brookhaven National Lab's National Synchrotron Light Source-II.

  8. Comparison of streamflow and water-quality data collection techniques for the Saginaw River, Michigan

    USGS Publications Warehouse

    Hoard, C.J.; Holtschlag, D.J.; Duris, J.W.; James, D.A.; Obenauer, D.J.

    2012-01-01

    In 2009, the Michigan Department of Environmental Quality and the U.S. Geological Survey developed a plan to compare the effect of various streamgaging and water-quality collection techniques on streamflow and stream water-quality data for the Saginaw River, Michigan. The Saginaw River is the primary contributor of surface runoff to Saginaw Bay, Lake Huron, draining approximately 70 percent of the Saginaw Bay watershed. The U.S. Environmental Protection Agency has listed the Saginaw Bay system as an "Area of Concern" due to many factors, including excessive sediment and nutrient concentrations in the water. Current efforts to estimate loading of sediment and nutrients to Saginaw Bay utilize water-quality samples collected using a surface-grab technique and flow data that are uncertain during specific conditions. Comparisons of current flow and water-quality sampling techniques to alternative techniques were assessed between April 2009 and September 2009 at two locations in the Saginaw River. Streamflow estimated using acoustic Doppler current profiling technology was compared to a traditional stage-discharge technique. Complex conditions resulting from the influence of Saginaw Bay on the Saginaw River were able to be captured using the acoustic technology, while the traditional stage-discharge technique failed to quantify these effects. Water-quality samples were collected at two locations and on eight different dates, utilizing both surface-grab and depth-integrating multiple-vertical techniques. Sixteen paired samples were collected and analyzed for suspended sediment, turbidity, total phosphorus, total nitrogen, orthophosphate, nitrite, nitrate, and ammonia. Results indicate that concentrations of constituents associated with suspended material, such as suspended sediment, turbidity, and total phosphorus, are underestimated when samples are collected using the surface-grab technique. The median magnitude of the relative percent difference in concentration based on sampling technique was 37 percent for suspended sediment, 26 percent for turbidity, and 9.7 percent for total phosphorus samples collected at both. Acoustic techniques were also used to assist in the determination of the effectiveness of using acoustic-backscatter information for estimating the suspended-sediment concentration of the river water. Backscatter data was collected by use of an acoustic Doppler current profiler, and a Van Dorn manual sampler was simultaneously used to collect discrete water samples at 10 depths (3.5, 7.5, 11, 14, 15.5, 17.5, 19.5, 20.5, 22, and 24.5 ft below the water surface) along two vertical profiles near the center of the Saginaw River near Bay City. The Van Dorn samples were analyzed for suspended-sediment concentrations, and these data were then used to develop a relationship between acoustic-backscatter data. Acoustic-backscatter data was strongly correlated to sediment concentrations and, by using a linear regression, was able to explain 89 percent of the variability. Although this regression technique showed promise for using acoustic backscatter to estimate suspended-sediment concentration, attempts to compare suspended-sediment concentrations to the acoustic signal-to-noise ratio estimates, recorded at the fixed acoustic streamflow-gaging station near Bay City (04157061), resulted in a poor correlation.

  9. When continuous observations just won't do: developing accurate and efficient sampling strategies for the laying hen.

    PubMed

    Daigle, Courtney L; Siegford, Janice M

    2014-03-01

    Continuous observation is the most accurate way to determine animals' actual time budget and can provide a 'gold standard' representation of resource use, behavior frequency, and duration. Continuous observation is useful for capturing behaviors that are of short duration or occur infrequently. However, collecting continuous data is labor intensive and time consuming, making multiple individual or long-term data collection difficult. Six non-cage laying hens were video recorded for 15 h and behavioral data collected every 2 s were compared with data collected using scan sampling intervals of 5, 10, 15, 30, and 60 min and subsamples of 2 second observations performed for 10 min every 30 min, 15 min every 1 h, 30 min every 1.5 h, and 15 min every 2 h. Three statistical approaches were used to provide a comprehensive analysis to examine the quality of the data obtained via different sampling methods. General linear mixed models identified how the time budget from the sampling techniques differed from continuous observation. Correlation analysis identified how strongly results from the sampling techniques were associated with those from continuous observation. Regression analysis identified how well the results from the sampling techniques were associated with those from continuous observation, changes in magnitude, and whether a sampling technique had bias. Static behaviors were well represented with scan and time sampling techniques, while dynamic behaviors were best represented with time sampling techniques. Methods for identifying an appropriate sampling strategy based upon the type of behavior of interest are outlined and results for non-caged laying hens are presented. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Evaluation of standard methods for collecting and processing fuel moisture samples

    Treesearch

    Sally M. Haase; José Sánchez; David R. Weise

    2016-01-01

    A variety of techniques for collecting and processing samples to determine moisture content of wildland fuels in support of fire management activities were evaluated. The effects of using a chainsaw or handsaw to collect samples of largediameter wood, containers for storing and transporting collected samples, and quick-response ovens for estimating moisture content...

  11. Extending the Collection Duration of Breath Samples for Enteric Methane Emission Estimation Using the SF6 Tracer Technique

    PubMed Central

    Pinares-Patiño, César; Gere, José; Williams, Karen; Gratton, Roberto; Juliarena, Paula; Molano, German; MacLean, Sarah; Sandoval, Edgar; Taylor, Grant; Koolaard, John

    2012-01-01

    Simple Summary Extended sample collection for the SF6 tracer technique is desirable for extensive grazing systems. Breath samples from eight cows were collected while lucerne silage was fed to achieve fixed intakes among the cows. Samples were collected over a 10-day period, using either apparatuses used in New Zealand (NZL) or Argentina (ARG), and either daily, over two consecutive 5-day periods or over a 10-day period (in duplicate). The NZL system had a greater sampling success and more consistent CH4 emission estimates than the ARG system, with no differences in mean emissions among sample collection periods. This study showed that extended sample collection is feasible, but definitive evaluation under grazing situation is required before a decision on recommendation can be made. Abstract The daily sample collection protocol of the sulphur hexafluoride (SF6) tracer technique for the estimation of methane (CH4) emissions from ruminants may not be practical under extensive grazing systems. Here, under controlled conditions, we evaluated extended periods of sampling as an alternative to daily sample collections. Eight rumen-fistulated cows were housed and fed lucerne silage to achieve common daily feed intakes of 6.4 kg dry matter per cow. Following SF6 permeation tube dosing, eight sampling lines were fitted to the breath collection harness, so that a common gas mix was available to each line. Half of the lines collected samples into PVC yokes using a modified capillary system as commonly used in New Zealand (NZL), and half collected samples into stainless steel cylinders using a ball-bearing flow restrictor as used in Argentina (ARG), all within a 10-day time frame, either daily, across two consecutive 5-day periods or across one 10-day period (in duplicate). The NZL system had greater sampling success (97.3 vs. 79.5%) and yielded more consistent CH4 emission estimates than the ARG system. Emission estimates from NZL daily, NZL 5-day and NZL 10-day samplings were 114, 110 and 111 g d−1, respectively. Extended sample collection protocol may be feasible, but definitive evaluation of this alternative as well as sample collection systems is required under grazing situations before a decision on recommendation can be made. PMID:26486921

  12. The effect of a cannula milk sampling technique on the microbiological diagnosis of bovine mastitis.

    PubMed

    Friman, M; Hiitiö, H; Niemi, M; Holopainen, J; Pyörälä, S; Simojoki, H

    2017-08-01

    Two methods of collecting milk samples from mastitic bovine mammary quarters were compared. Samples were taken in a consistent order in which standard aseptic technique sampling was done first, followed by insertion of a sterile cannula through the teat canal and collection of a second sample. Microbiological results of those two sampling techniques were compared. Milk samples were analysed using multiplex real-time polymerase chain reaction (PCR). The cannula technique produced a reduced number of microbial species or groups of species per sample compared with conventional sampling. Staphylococcus spp. were the most common species identified and were detected more often during conventional sampling than with cannula sampling. Staphylococcus spp. identified in milk samples could also have originated from the teat canal without being present in the milk. The number of samples positive for Trueperella pyogenes or yeasts in the conventional samples was twice as high as in the cannula samples, indicating that the presence of Trueperella pyogenes and yeast species should not necessarily be interpreted as being the causative agents of bovine intra-mammary infections (IMI). Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Measurements of Organic Composition of Aerosol and Rainwater Samples Using Offline Aerosol Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    OBrien, R. E.; Ridley, K. J.; Canagaratna, M. R.; Croteau, P.; Budisulistiorini, S. H.; Cui, T.; Green, H. S.; Surratt, J. D.; Jayne, J. T.; Kroll, J. H.

    2016-12-01

    A thorough understanding of the sources, evolution, and budgets of atmospheric organic aerosol requires widespread measurements of the amount and chemical composition of atmospheric organic carbon in the condensed phase (within particles and water droplets). Collecting such datasets requires substantial spatial and temporal (long term) coverage, which can be challenging when relying on online measurements by state-of-the-art research-grade instrumentation (such as those used in atmospheric chemistry field studies). Instead, samples are routinely collected using relatively low-cost techniques, such as aerosol filters, for offline analysis of their chemical composition. However, measurements made by online and offline instruments can be fundamentally different, leading to disparities between data from field studies and those from more routine monitoring. To better connect these two approaches, and take advantage of the benefits of each, we have developed a method to introduce collected samples into online aerosol instruments using nebulization. Because nebulizers typically require tens to hundreds of milliliters of solution, limiting this technique to large samples, we developed a new, ultrasonic micro-nebulizer that requires only small volumes (tens of microliters) of sample for chemical analysis. The nebulized (resuspended) sample is then sent into a high-resolution Aerosol Mass Spectrometer (AMS), a widely-used instrument that provides key information on the chemical composition of aerosol particulate matter (elemental ratios, carbon oxidation state, etc.), measurements that are not typically made for collected atmospheric samples. Here, we compare AMS data collected using standard on-line techniques with our offline analysis, demonstrating the utility of this new technique to aerosol filter samples. We then apply this approach to organic aerosol filter samples collected in remote regions, as well as rainwater samples from across the US. This data provides information on the sample composition and changes in key chemical characteristics across locations and seasons.

  14. Characterization of Macroinvertebrate Communities in the Hyporheic Zone of River Ecosystems Reflects the Pump-Sampling Technique Used

    PubMed Central

    Dole-Olivier, Marie-José; Galassi, Diana M. P.; Hogan, John-Paul; Wood, Paul J.

    2016-01-01

    The hyporheic zone of river ecosystems provides a habitat for a diverse macroinvertebrate community that makes a vital contribution to ecosystem functioning and biodiversity. However, effective methods for sampling this community have proved difficult to establish, due to the inaccessibility of subsurface sediments. The aim of this study was to compare the two most common semi-quantitative macroinvertebrate pump-sampling techniques: Bou-Rouch and vacuum-pump sampling. We used both techniques to collect replicate samples in three contrasting temperate-zone streams, in each of two biogeographical regions (Atlantic region, central England, UK; Continental region, southeast France). Results were typically consistent across streams in both regions: Bou-Rouch samples provided significantly higher estimates of taxa richness, macroinvertebrate abundance, and the abundance of all UK and eight of 10 French common taxa. Seven and nine taxa which were rare in Bou-Rouch samples were absent from vacuum-pump samples in the UK and France, respectively; no taxon was repeatedly sampled exclusively by the vacuum pump. Rarefaction curves (rescaled to the number of incidences) and non-parametric richness estimators indicated no significant difference in richness between techniques, highlighting the capture of more individuals as crucial to Bou-Rouch sampling performance. Compared to assemblages in replicate vacuum-pump samples, multivariate analyses indicated greater distinction among Bou-Rouch assemblages from different streams, as well as significantly greater consistency in assemblage composition among replicate Bou-Rouch samples collected in one stream. We recommend Bou-Rouch sampling for most study types, including rapid biomonitoring surveys and studies requiring acquisition of comprehensive taxon lists that include rare taxa. Despite collecting fewer macroinvertebrates, vacuum-pump sampling remains an important option for inexpensive and rapid sample collection. PMID:27723819

  15. Mosquitoes (Diptera: Culicidae) Collected From Residential Yards and Dog Kennels in Florida Using Two Aspirators, a Sweep Net, or a CDC Trap.

    PubMed

    Holderman, C J; Gezan, S A; Stone, A E S; Connelly, C R; Kaufman, P E

    2018-01-10

    Mosquito surveillance typically uses Centers for Disease Control and Prevention (CDC) mosquito light traps baited with CO2. From January 2013 to March 2015, we sampled seven field sites using three active mosquito-trapping techniques (two different aspirators and a sweep net) and the stationary CO2-baited CDC mosquito light trap to determine mosquito capture efficacy for each technique. Sampling occurred in four suburban backyards and three dog kennel facilities near Gainesville, FL, USA; species collection and relative abundance were measured. A total of 32 species and 70,090 individual mosquitoes were collected, including a new record for Alachua County, Florida, Aedes hendersoni (Cockerell). The dominant (>5% of total capture) mosquito species collected during the study included Aedes atlanticus (Dyar and Knab), Aedes infirmatus (Dyar and Knab), Anopheles crucians Wiedemann, Culiseta melanura (Coquillett), Culex erraticus (Dyar and Knab), Culex nigripalpus Theobald, and Uranotaenia sapphirina (Osten Sacken). The CDC trap captured the most species (29), followed by large aspirator (28), small aspirator (26), and the sweep net (23). All dominant species were captured with each sampling technique. Excluding Wyeomyia mitchellii (Theobald), all subdominant species (1-5% of total capture) were collected with each sampling technique. Future sampling should consider the utility (e.g., large numbers are readily collected) and limitations (e.g., personnel requirements) of aspirator collections when designing field-based mosquito sampling projects, especially those in residential areas or those focused upon species captured. © The Author(s) 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. Non-Destructive Classification Approaches for Equilbrated Ordinary Chondrites

    NASA Technical Reports Server (NTRS)

    Righter, K.; Harrington, R.; Schroeder, C.; Morris, R. V.

    2013-01-01

    Classification of meteorites is most effectively carried out by petrographic and mineralogic studies of thin sections, but a rapid and accurate classification technique for the many samples collected in dense collection areas (hot and cold deserts) is of great interest. Oil immersion techniques have been used to classify a large proportion of the US Antarctic meteorite collections since the mid-1980s [1]. This approach has allowed rapid characterization of thousands of samples over time, but nonetheless utilizes a piece of the sample that has been ground to grains or a powder. In order to compare a few non-destructive techniques with the standard approaches, we have characterized a group of chondrites from the Larkman Nunatak region using magnetic susceptibility and Moessbauer spectroscopy.

  17. Advanced Navigation Strategies for an Asteroid Sample Return Mission

    NASA Technical Reports Server (NTRS)

    Bauman, J.; Getzandanner, K.; Williams, B.; Williams, K.

    2011-01-01

    The proximity operations phases of a sample return mission to an asteroid have been analyzed using advanced navigation techniques derived from experience gained in planetary exploration. These techniques rely on tracking types such as Earth-based radio metric Doppler and ranging, spacecraft-based ranging, and optical navigation using images of landmarks on the asteroid surface. Navigation strategies for the orbital phases leading up to sample collection, the touch down for collecting the sample, and the post sample collection phase at the asteroid are included. Options for successfully executing the phases are studied using covariance analysis and Monte Carlo simulations of an example mission to the near Earth asteroid 4660 Nereus. Two landing options were studied including trajectories with either one or two bums from orbit to the surface. Additionally, a comparison of post-sample collection strategies is presented. These strategies include remaining in orbit about the asteroid or standing-off a given distance until departure to Earth.

  18. Flagging versus dragging as sampling methods for nymphal Ixodes scapularis (Acari: Ixodidae)

    USGS Publications Warehouse

    Rulison, Eric L.; Kuczaj, Isis; Pang, Genevieve; Hickling, Graham J.; Tsao, Jean I.; Ginsberg, Howard S.

    2013-01-01

    The nymphal stage of the blacklegged tick, Ixodes scapularis (Acari: Ixodidae), is responsible for most transmission of Borrelia burgdorferi, the etiologic agent of Lyme disease, to humans in North America. From 2010 to fall of 2012, we compared two commonly used techniques, flagging and dragging, as sampling methods for nymphal I. scapularis at three sites, each with multiple sampling arrays (grids), in the eastern and central United States. Flagging and dragging collected comparable numbers of nymphs, with no consistent differences between methods. Dragging collected more nymphs than flagging in some samples, but these differences were not consistent among sites or sampling years. The ratio of nymphs collected by flagging vs dragging was not significantly related to shrub density, so habitat type did not have a strong effect on the relative efficacy of these methods. Therefore, although dragging collected more ticks in a few cases, the numbers collected by each method were so variable that neither technique had a clear advantage for sampling nymphal I. scapularis.

  19. Accurate low-cost methods for performance evaluation of cache memory systems

    NASA Technical Reports Server (NTRS)

    Laha, Subhasis; Patel, Janak H.; Iyer, Ravishankar K.

    1988-01-01

    Methods of simulation based on statistical techniques are proposed to decrease the need for large trace measurements and for predicting true program behavior. Sampling techniques are applied while the address trace is collected from a workload. This drastically reduces the space and time needed to collect the trace. Simulation techniques are developed to use the sampled data not only to predict the mean miss rate of the cache, but also to provide an empirical estimate of its actual distribution. Finally, a concept of primed cache is introduced to simulate large caches by the sampling-based method.

  20. Evaluation of Skin Surface as an Alternative Source of Reference DNA Samples: A Pilot Study.

    PubMed

    Albujja, Mohammed H; Bin Dukhyil, Abdul Aziz; Chaudhary, Abdul Rauf; Kassab, Ahmed Ch; Refaat, Ahmed M; Babu, Saranya Ramesh; Okla, Mohammad K; Kumar, Sachil

    2018-01-01

    An acceptable area for collecting DNA reference sample is a part of the forensic DNA analysis development. The aim of this study was to evaluate skin surface cells (SSC) as an alternate source of reference DNA sample. From each volunteer (n = 10), six samples from skin surface areas (forearm and fingertips) and two traditional samples (blood and buccal cells) were collected. Genomic DNA was extracted and quantified then genotyped using standard techniques. The highest DNA concentration of SSC samples was collected using the tape/forearm method of collection (2.1 ng/μL). Cotton swabs moistened with ethanol yielded higher quantities of DNA than swabs moistened with salicylic acid, and it gave the highest percentage of full STR profiles (97%). This study supports the use of SSC as a noninvasive sampling technique and as a extremely useful source of DNA reference samples among certain cultures where the use of buccal swabs can be considered socially unacceptable. © 2017 American Academy of Forensic Sciences.

  1. Introduction to Field Water-Quality Methods for the Collection of Metals - 2007 Project Summary

    USGS Publications Warehouse

    Allen, Monica L.

    2008-01-01

    The U.S. Geological Survey (USGS), Region VI of the U.S. Environmental Protection Agency (USEPA), and the Osage Nation presented three 3-day workshops, in June-August 2007, entitled ?Introduction to Field Water-Quality Methods for the Collection of Metals.? The purpose of the workshops was to provide instruction to tribes within USEPA Region VI on various USGS surface-water measurement methods and water-quality sampling protocols for the collection of surface-water samples for metals analysis. Workshop attendees included members from over 22 tribes and pueblos. USGS instructors came from Oklahoma, New Mexico, and Georgia. Workshops were held in eastern and south-central Oklahoma and New Mexico and covered many topics including presampling preparation, water-quality monitors, and sampling for metals in surface water. Attendees spent one full classroom day learning the field methods used by the USGS Water Resources Discipline and learning about the complexity of obtaining valid water-quality and quality-assurance data. Lectures included (1) a description of metal contamination sources in surface water; (2) introduction on how to select field sites, equipment, and laboratories for sample analysis; (3) collection of sediment in surface water; and (4) utilization of proper protocol and methodology for sampling metals in surface water. Attendees also were provided USGS sampling equipment for use during the field portion of the class so they had actual ?hands-on? experience to take back to their own organizations. The final 2 days of the workshop consisted of field demonstrations of current USGS water-quality sample-collection methods. The hands-on training ensured that attendees were exposed to and experienced proper sampling procedures. Attendees learned integrated-flow techniques during sample collection, field-property documentation, and discharge measurements and calculations. They also used enclosed chambers for sample processing and collected quality-assurance samples to verify their techniques. Benefits of integrated water-quality sample-collection methods are varied. Tribal environmental programs now have the ability to collect data that are comparable across watersheds. The use of consistent sample collection, manipulation, and storage techniques will provide consistent quality data that will enhance the understanding of local water resources. The improved data quality also will help the USEPA better document the condition of the region?s water. Ultimately, these workshops equipped tribes to use uniform sampling methods and to provide consistent quality data that are comparable across the region.

  2. Comparison of Submental Blood Collection with the Retroorbital and Submandibular Methods in Mice (Mus musculus)

    PubMed Central

    Regan, Rainy D; Fenyk-Melody, Judy E; Tran, Sam M; Chen, Guang; Stocking, Kim L

    2016-01-01

    Nonterminal blood sample collection of sufficient volume and quality for research is complicated in mice due to their small size and anatomy. Large (>100 μL) nonterminal volumes of unhemolyzed or unclotted blood currently are typically collected from the retroorbital sinus or submandibular plexus. We developed a third method—submental blood collection—which is similar in execution to the submandibular method but with minor changes in animal restraint and collection location. Compared with other techniques, submental collection is easier to perform due to the direct visibility of the target vessels, which are located in a sparsely furred region. Compared with the submandibular method, the submental method did not differ regarding weight change and clotting score but significantly decreased hemolysis and increased the overall number of high-quality samples. The submental method was performed with smaller lancets for the majority of the bleeds, yet resulted in fewer repeat collection attempts, fewer insufficient samples, and less extraneous blood loss and was qualitatively less traumatic. Compared with the retroorbital technique, the submental method was similar regarding weight change but decreased hemolysis, clotting, and the number of overall high-quality samples; however the retroorbital method resulted in significantly fewer incidents of insufficient sample collection. Extraneous blood loss was roughly equivalent between the submental and retroorbital methods. We conclude that the submental method is an acceptable venipuncture technique for obtaining large, nonterminal volumes of blood from mice. PMID:27657712

  3. Qualitative research in nutrition and dietetics: data collection issues.

    PubMed

    Draper, A; Swift, J A

    2011-02-01

    The wide scope of qualitative enquiry presents the researcher with a number of choices regarding data collection and sampling. Selecting data collection and sampling techniques can therefore be somewhat daunting, particularly because, often, there is no single, universally accepted 'correct' option. Appropriate research methods are, however, crucial to ensure high-quality research. This review, the second in the series, provides an overview of the principal techniques of data collection and sampling that may be used for qualitative research in nutrition and dietetics. In addition, it describes a process for choosing appropriate data collection and sampling methods that considers the extent to which they provide data that answers the research question(s) and are compatible with the philosophical assumptions about ontology, epistemology and methodology that underpin the overall design of a study. Finally, it discusses the central role that the researcher plays in qualitative data collection and encourages researchers to acknowledge and reflect upon their impact on the data. Other reviews in this series provide a model for embarking on a qualitative research project in nutrition and dietetics, an overview of the principal techniques of data analysis and quality assessment of this kind of research, and some practical advice relevant to nutrition and dietetics, along with glossaries of key terms. © 2010 The Authors. Journal compilation © 2010 The British Dietetic Association Ltd.

  4. A single-sampling hair trap for mesocarnivores

    Treesearch

    Jonathan N. Pauli; Matthew B. Hamilton; Edward B. Crain; Steven W. Buskirk

    2007-01-01

    Although techniques to analyze and quantifY DNA-based data have progressed, methods to noninvasively collect samples lag behind. Samples are generally collected from devices that permit coincident sampling of multiple individuals. Because of cross-contamination, substantive genotyping errors can arise. We developed a cost-effective (US$4.60/trap) single-capture hair...

  5. Clean and Cold Sample Curation

    NASA Technical Reports Server (NTRS)

    Allen, C. C.; Agee, C. B.; Beer, R.; Cooper, B. L.

    2000-01-01

    Curation of Mars samples includes both samples that are returned to Earth, and samples that are collected, examined, and archived on Mars. Both kinds of curation operations will require careful planning to ensure that the samples are not contaminated by the instruments that are used to collect and contain them. In both cases, sample examination and subdivision must take place in an environment that is organically, inorganically, and biologically clean. Some samples will need to be prepared for analysis under ultra-clean or cryogenic conditions. Inorganic and biological cleanliness are achievable separately by cleanroom and biosafety lab techniques. Organic cleanliness to the <50 ng/sq cm level requires material control and sorbent removal - techniques being applied in our Class 10 cleanrooms and sample processing gloveboxes.

  6. Guidelines for collection and field analysis of ground-water samples for selected unstable constituents

    USGS Publications Warehouse

    Wood, Warren W.

    1976-01-01

    The unstable nature of many chemical and physical constituents in ground water requires special collection procedures and field analysis immediately after collection. This report describes the techniques and equipment commonly used m the collection and field analysis of samples for pH, temperature, carbonate, bicarbonate, specific conductance, Eh, and dissolved oxygen.

  7. Adventures in Uncertainty: An Empirical Investigation of the Use of a Taylor's Series Approximation for the Assessment of Sampling Errors in Educational Research.

    ERIC Educational Resources Information Center

    Wilson, Mark

    This study investigates the accuracy of the Woodruff-Causey technique for estimating sampling errors for complex statistics. The technique may be applied when data are collected by using multistage clustered samples. The technique was chosen for study because of its relevance to the correct use of multivariate analyses in educational survey…

  8. Preparation of Cytology Samples: Tricks of the Trade.

    PubMed

    Moore, A Russell

    2017-01-01

    General principles and techniques for collection, preparation, and staining of cytologic samples in the general practice setting are reviewed. Tips for collection of digital images are also discussed. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. A refined electrofishing technique for collecting Silver Carp: Implications for management

    USGS Publications Warehouse

    Bouska, Wesley W.; Glover, David C.; Bouska, Kristen; Garvey, James E.

    2017-01-01

    Detecting nuisance species at low abundance or in newly established areas is critical to developing pest management strategies. Due to their sensitivity to disturbance and erratic jumping behavior, Silver Carp Hypophthalmichthys molitrix can be difficult to collect with traditional sampling methods. We compared catch per unit effort (CPUE) of all species from a Long Term Resource Monitoring (LTRM) electrofishing protocol to an experimental electrofishing technique designed to minimize Silver Carp evasion through tactical boat maneuvering and selective application of power. Differences in CPUE between electrofishing methods were detected for 2 of 41 species collected across 2 years of sampling at 20 sites along the Illinois River. The mean catch rate of Silver Carp using the experimental technique was 2.2 times the mean catch rate of the LTRM electrofishing technique; the increased capture efficiency at low relative abundance emphasizes the utility of this method for early detection. The experimental electrofishing also collected slightly larger Silver Carp (mean: 510.7 mm TL versus 495.2 mm TL), and nearly four times as many Silver Carp independently jumped into the boat during experimental transects. Novel sampling approaches, such as the experimental electrofishing technique used in this study, should be considered to increase probability of detection for aquatic nuisance species.

  10. In vivo testing for gold nanoparticle toxicity.

    PubMed

    Simpson, Carrie A; Huffman, Brian J; Cliffel, David E

    2013-01-01

    A technique for measuring the toxicity of nanomaterials using a murine model is described. Blood samples are collected via submandibular bleeding while urine samples are collected on cellophane sheets. Both biosamples are then analyzed by inductively coupled plasma optical emission spectroscopy (ICP-OES) for nanotoxicity. Blood samples are further tested for immunological response using a standard Coulter counter. The major organs of interest for filtration are also digested and analyzed via ICP-OES, producing useful information regarding target specificity of the nanomaterial of interest. Collection of the biosamples and analysis afterward is detailed, and the operation of the technique is described and illustrated by analysis of the nanotoxicity of an injection of a modified tiopronin monolayer-protected cluster.

  11. Micropowder collecting technique for stable isotope analysis of carbonates.

    PubMed

    Sakai, Saburo; Kodan, Tsuyoshi

    2011-05-15

    Micromilling is a conventional technique used in the analysis of the isotopic composition of geological materials, which improves the spatial resolution of sample collection for analysis. However, a problem still remains concerning the recovery ratio of the milled sample. We constructed a simple apparatus consisting of a vacuum pump, a sintered metal filter, electrically conductive rubber stopper and a stainless steel tube for transferring the milled powder into a reaction vial. In our preliminary experiments on carbonate powder, we achieved a rapid recovery of 5 to 100 µg of carbonate with a high recovery ratio (>90%). This technique shortens the sample preparation time, improves the recovery ratio, and homogenizes the sample quantity, which, in turn, improves the analytical reproducibility. Copyright © 2011 John Wiley & Sons, Ltd.

  12. Advanced Curation Preparation for Mars Sample Return and Cold Curation

    NASA Technical Reports Server (NTRS)

    Fries, M. D.; Harrington, A. D.; McCubbin, F. M.; Mitchell, J.; Regberg, A. B.; Snead, C.

    2017-01-01

    NASA Curation is tasked with the care and distribution of NASA's sample collections, such as the Apollo lunar samples and cometary material collected by the Stardust spacecraft. Curation is also mandated to perform Advanced Curation research and development, which includes improving the curation of existing collections as well as preparing for future sample return missions. Advanced Curation has identified a suite of technologies and techniques that will require attention ahead of Mars sample return (MSR) and missions with cold curation (CCur) requirements, perhaps including comet sample return missions.

  13. A LITERATURE REVIEW OF WIPE SAMPLING METHODS ...

    EPA Pesticide Factsheets

    Wipe sampling is an important technique for the estimation of contaminant deposition in buildings, homes, or outdoor surfaces as a source of possible human exposure. Numerousmethods of wipe sampling exist, and each method has its own specification for the type of wipe, wetting solvent, and determinative step to be used, depending upon the contaminant of concern. The objective of this report is to concisely summarize the findings of a literature review that was conducted to identify the state-of-the-art wipe sampling techniques for a target list of compounds. This report describes the methods used to perform the literature review; a brief review of wipe sampling techniques in general; an analysis of physical and chemical properties of each target analyte; an analysis of wipe sampling techniques for the target analyte list; and asummary of the wipe sampling techniques for the target analyte list, including existing data gaps. In general, no overwhelming consensus can be drawn from the current literature on how to collect a wipe sample for the chemical warfare agents, organophosphate pesticides, and other toxic industrial chemicals of interest to this study. Different methods, media, and wetting solvents have been recommended and used by various groups and different studies. For many of the compounds of interest, no specific wipe sampling methodology has been established for their collection. Before a wipe sampling method (or methods) can be established for the co

  14. Operational Cyber Testing Recommendations- Version 1

    DTIC Science & Technology

    2014-05-02

    be used to verify 5 representative pieces of the environment via sample test runs. Also, ideally, an early version of each test case can also be stood...extraneous effort). Comparing the sample results collected from the scripts with expected results can reveal deficiencies in the data collection techniques...the reporting mechanisms, and the system components themselves. The sample results can also be used for confirming that data is collected with high

  15. Artist Material BRDF Database for Computer Graphics Rendering

    NASA Astrophysics Data System (ADS)

    Ashbaugh, Justin C.

    The primary goal of this thesis was to create a physical library of artist material samples. This collection provides necessary data for the development of a gonio-imaging system for use in museums to more accurately document their collections. A sample set was produced consisting of 25 panels and containing nearly 600 unique samples. Selected materials are representative of those commonly used by artists both past and present. These take into account the variability in visual appearance resulting from the materials and application techniques used. Five attributes of variability were identified including medium, color, substrate, application technique and overcoat. Combinations of these attributes were selected based on those commonly observed in museum collections and suggested by surveying experts in the field. For each sample material, image data is collected and used to measure an average bi-directional reflectance distribution function (BRDF). The results are available as a public-domain image and optical database of artist materials at art-si.org. Additionally, the database includes specifications for each sample along with other information useful for computer graphics rendering such as the rectified sample images and normal maps.

  16. [Standardization of Blastocystis hominis diagnosis using different staining techniques].

    PubMed

    Eymael, Dayane; Schuh, Graziela Maria; Tavares, Rejane Giacomelli

    2010-01-01

    The present study was carried out from March to May 2008, with the aim of evaluating the effectiveness of different techniques for diagnosing Blastocystis hominis in a sample of the population attended at the Biomedicine Laboratory of Feevale University, Novo Hamburgo, Rio Grande do Sul. On hundred feces samples from children and adults were evaluated. After collection, the samples were subjected to the techniques of spontaneous sedimentation (HPJ), sedimentation in formalin-ether (Ritchie) and staining by means of Gram and May-Grünwald-Giemsa (MGG). The presence of Blastocystis hominis was observed in 40 samples, when staining techniques were used (MGG and Gram), while sedimentation techniques were less efficient (32 positive samples using the Ritchie technique and 20 positive samples using the HPJ technique). Our results demonstrate that HPJ was less efficient than the other methods, thus indicating the need to include laboratory techniques that enable parasite identification on a routine basis.

  17. Computational Approaches for Predicting Nonlinear Interactions of Chemical Mixtures in Biological Systems

    DTIC Science & Technology

    2009-12-01

    exposure. Feces samples were collected at 24hrs and 48hrs. No fecal matter was present at 6hrs. Urine samples were collected at 6hrs, 24hrs and 48hrs...atmosphere sampling technique (Tremblay et al, in press) to characterize the inhalation exposure chamber for JP-8 and S- 8 exposures at Loma Linda Veterans... samples were collected for 1 min at 400 mL/min and quantified using thermal desorption gas chromatography mass spectrometry (TDS-GC/MS). The method was

  18. The Preliminary Examination of Organics in the Returned Stardust Samples from Comet Wild 2

    NASA Technical Reports Server (NTRS)

    Sandford, S. A.; Aleon, J.; Alexander, C.; Butterworth, A.; Clemett, S. J.; Cody, G.; Cooper, G.; Dworkin, J. P.; Flynn, G. J.; Gilles, M. K.

    2006-01-01

    The primary objective of STARDUST is to collect coma samples from comet 8lP/Wild 2. These samples were collected by impact onto aerogel tiles on Jan 2, 2004 when the spacecraft flew through the comet's coma at a relative velocity of about 6.1 km/sec. Measurements of dust impacts on the front of the spacecraft suggest that the aerogel particle collector was impacted by 2800 +/- 500 particles larger than 15 micron in diameter. Following recovery of the Sample Return Capsule (SRC) on Jan 15, 2006, the aerogel collector trays will be removed in a clean room at JSC. After documentation of the collection, selected aerogel tiles will be removed and aerogel and cometary samples will be extracted for study. A number of different extraction techniques will be used, each optimized for the analytical technique that is to be used. The STARDUST Mission will carry out a 6 month preliminary examination (PE) of a small portion of the returned samples. The examination of the samples will be made by a number of subteams that will concentrate on specific aspects of the samples. One of these is the Organics PE Team (see the author list above for team members). These team members will use a number of analytical techniques to produce a preliminary characterization of the abundance and nature of the organics (if any) in the returned samples.

  19. Attempted semen collection using the massage technique in blue-fronted Amazon parrots (Amazona aestiva aestiva).

    PubMed

    Della Volpe, Angelique; Volker, Schmidt; Krautwald-Junghanns, Maria-Elisabeth

    2011-03-01

    The purpose of this study was to establish a technique for collecting semen from blue-fronted Amazon parrots (Amazona aestiva aestiva) and to evaluate the samples that were collected. The massage method is the most common technique used to collect semen in birds and has been proven successful in several psittacine species; however, collection attempts in larger parrots have been unsatisfactory. Six blue-fronted Amazon parrot males, 3 paired with hens and 3 unpaired, were used in this study. The semen collection technique was revised to allow collection from individual birds by a single person. Semen collection was attempted from the 6 parrots on 52-56 occasions, which totaled 330 single attempts. Nineteen ejaculates were collected, and each bird produced at least 1 ejaculate that contained spermatozoa. Large ranges of sample volume (1-15.4 microL), sperm quality (motility = 2%-60%; live:dead ratio = 2:198 to 185:15), sperm concentration (0.79-3.3 x 10(6) sperm/mL), and contamination rate (0%-100%) were observed. Measured parameters did not appear to be significantly impacted by birds being paired or kept singly. Because of the relatively short acclimation period, the birds appeared to be sexually inactive for the majority of the study. Further research using sexually active birds will be necessary to determine standard spermatological parameters and verify the success of the methodology used here.

  20. MEASUREMENTS OF AIR POLLUTANT BIOMARKERS WITH EXHALED BREATH TECHNIQUES

    EPA Science Inventory

    Use of exhaled breath condensate (EBC) has appeal as a noninvasive surrogate sample for lung-derived fluid. Additionally, EBC can be collected multiple times over the course of a study, unlike many other lung sampling techniques which can be performed fewer times. However validat...

  1. Methods for collection and analysis of aquatic biological and microbiological samples

    USGS Publications Warehouse

    Britton, L.J.; Greeson, P.E.

    1989-01-01

    The series of chapters on techniques describes methods used by the U.S. Geological Survey for planning and conducting water-resources investigations. The material is arranged under major subject headings called books and is further subdivided into sections and chapters. Book 5 is on laboratory analysis. Section A is on water. The unit of publication, the chapter, is limited to a narrow field of subject matter. "Methods for Collection and Analysis of Aquatic Biological and Microbiological Samples" is the fourth chapter to be published under Section A of Book 5. The chapter number includes the letter of the section.This chapter was prepared by several aquatic biologists and microbiologists of the U.S. Geological Survey to provide accurate and precise methods for the collection and analysis of aquatic biological and microbiological samples.Use of brand, firm, and trade names in this chapter is for identification purposes only and does not constitute endorsement by the U.S. Geological Survey.This chapter supersedes "Methods for Collection and Analysis of Aquatic Biological and Microbiological Samples" edited by P.E. Greeson, T.A. Ehlke, G.A. Irwin, B.W. Lium, and K.V. Slack (U.S. Geological Survey Techniques of Water-Resources Investigations, Book 5, Chapter A4, 1977) and also supersedes "A Supplement to-Methods for Collection and Analysis of Aquatic Biological and Microbiological Samples" by P.E. Greeson (U.S. Geological Survey Techniques of Water-Resources Investigations, Book 5, Chapter A4), Open-File Report 79-1279, 1979.

  2. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN USING COTTON GAUZE FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure, urine samples are often needed to analyze pesticide metabolites. However, this is difficult for children wearing diapers because simple and feasible techniques suitable for field collection are not available. The objectives of this study were to t...

  3. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN USING GAUZE FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure, urine samples are often needed to analyze pesticide metabolites. However, this is difficult for children wearing diapers because simple and feasible techniques suitable for field collection are not available. The objectives of this study were to te...

  4. A New Paradigm for Tissue Diagnostics: Tools and Techniques to Standardize Tissue Collection, Transport, and Fixation.

    PubMed

    Bauer, Daniel R; Otter, Michael; Chafin, David R

    2018-01-01

    Studying and developing preanalytical tools and technologies for the purpose of obtaining high-quality samples for histological assays is a growing field. Currently, there does not exist a standard practice for collecting, fixing, and monitoring these precious samples. There has been some advancement in standardizing collection for the highest profile tumor types, such as breast, where HER2 testing drives therapeutic decisions. This review examines the area of tissue collection, transport, and monitoring of formalin diffusion and details a prototype system that could be used to help standardize tissue collection efforts. We have surveyed recent primary literature sources and conducted several site visits to understand the most error-prone processes in histology laboratories. This effort identified errors that resulted from sample collection techniques and subsequent transport delays from the operating room (OR) to the histology laboratories. We have therefore devised a prototype sample collection and transport concept. The system consists of a custom data logger and cold transport box and takes advantage of a novel cold + warm (named 2 + 2) fixation method. This review highlights the beneficial aspects of standardizing tissue collection, fixation, and monitoring. In addition, a prototype system is introduced that could help standardize these processes and is compatible with use directly in the OR and from remote sites.

  5. Exploring high dimensional free energy landscapes: Temperature accelerated sliced sampling

    NASA Astrophysics Data System (ADS)

    Awasthi, Shalini; Nair, Nisanth N.

    2017-03-01

    Biased sampling of collective variables is widely used to accelerate rare events in molecular simulations and to explore free energy surfaces. However, computational efficiency of these methods decreases with increasing number of collective variables, which severely limits the predictive power of the enhanced sampling approaches. Here we propose a method called Temperature Accelerated Sliced Sampling (TASS) that combines temperature accelerated molecular dynamics with umbrella sampling and metadynamics to sample the collective variable space in an efficient manner. The presented method can sample a large number of collective variables and is advantageous for controlled exploration of broad and unbound free energy basins. TASS is also shown to achieve quick free energy convergence and is practically usable with ab initio molecular dynamics techniques.

  6. Determination of phenolic priority pollutants utilizing permeation sampling method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Guozheng.

    1990-01-01

    A passive permeation sampling method for the determination of phenolic priority pollutants in water was developed. Phenols in an aqueous solution permeate a polymeric membrane and are collected on a solid adsorbent in a sampling device. Both solvent and thermal desorption techniques were employed to recovery phenolic pollutants collected. In the solvent desorption, phenolic compounds collected on the XAD-7 resin, and then desorbed by acetonitrile. In the thermal desorption, phenolic compounds collected on Tenax-TA were recovered thermally, Separation and quantification is achieved by a SPB-5 capillary column gas chromatography using a flame ionization detector. There are linear relationships between themore » amount of phenolic compounds collected and the products of the exposure times and concentrations over the range from 5 ppb to 20 ppm with precisions no worse than 13%. The permeation rates of the phenolic pollutants depend upon the exposure temperature, solution pH and membrane area. Samples collected can be stored for up to two weeks without loss. This method provides a simple, convenient and inexpensive way for monitoring the time-weighted-average concentration without the use of a pumping system. An automated sampler which combines the permeation and the thermal desorption techniques together was also developed for water sample obtained from grab sampling. The on-line setup provides a high degree of automation. Detection limits at 10 ppb can be achieved using this sampler.« less

  7. Study of the atmospheric aerosol composition in equatorial Africa using PIXE as analytical technique

    NASA Astrophysics Data System (ADS)

    Maenhaut, W.; Akilimali, K.

    1987-03-01

    Small Nuclepore total filter holders and a single orifice 8-stage cascade impactor were used to collect atmospheric aerosol samples in Kinshasa, Zaire, and Butare, Rwanda. The samples were analyzed for about 20 elements by means of the PIXE technique. The results obtained for parallel samples, taken with two total filter holders and one cascade impactor, were generally in excellent agreement, suggesting that the different samplers collected very similar aerosol particle populations. Most elements were associated with a crustal dust dispersion source, which may include road dust dispersal. The Butare samples, particularly those collected during the night, were significantly influenced by biomass burning, as was deduced from enhanced filter blackness and noncrustal K levels. The pyrogenic component also contained P, S, Mn and Rb. Br and Pb were highly enriched at both locations, indicating that automotive sources had a strong influence on the aerosol composition.

  8. A novel method for semen collection and artificial insemination in large parrots (Psittaciformes)

    PubMed Central

    Lierz, Michael; Reinschmidt, Matthias; Müller, Heiner; Wink, Michael; Neumann, Daniel

    2013-01-01

    The paper described a novel technique for semen collection in large psittacines (patent pending), a procedure which was not routinely possible before. For the first time, a large set of semen samples is now available for analysis as well as for artificial insemination. Semen samples of more than 100 psittacine taxa were collected and analysed; data demonstrate large differences in the spermatological parameters between families, indicating an ecological relationship with breeding behaviour (polygamous versus monogamous birds). Using semen samples for artificial insemination resulted in the production of offspring in various families, such as Macaws and Cockatoos, for the first time ever. The present technique represents a breakthrough in species conservation programs and will enable future research into the ecology and environmental factors influencing endangered species. PMID:23797622

  9. [Comparison of the determination of cyclosporin-A in blood samples collected on filter paper and by the ordinary technique].

    PubMed

    Azevedo, L S; Manrique, R; Sabbaga, E

    1995-01-01

    Monitoring cyclosporin-A (CsA) blood levels is of utmost importance for the rational use of this drug. Although many centers perform transplants, in Brazil there are few laboratories able to measure CsA blood levels. Therefore making blood samples reach the laboratory emerged as a problem. Collection of blood on filter paper has been a technique used for a long time in special cases. PURPOSE--To confirm the usefulness of measuring CsA blood levels in blood samples collected on filter paper and in the usual way. METHOD--We studied twenty renal cadaver kidney recipients who were receiving CsA, azathioprine and prednisone. Ninety five blood samples were collected and divided into two aliquots. One of them was sent routinely to one laboratory to perform whole blood CsA measurements. From the other aliquot, 20 microliters were pipetted on filter paper. When dried they were mailed to the other laboratory, where, after elution, CsA was measured. In both cases radioimmunoassay with polyclonal antibody was used. RESULTS--Linear correlation between both measurements revealed r = 0.81 with no statistical difference. CONCLUSION--The technique showed to be useful in clinical practice. In countries with continental size, as Brazil, it may be very helpful.

  10. Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure with image analysis

    DOEpatents

    Van Berkel, Gary J.; Kertesz, Vilmos

    2011-08-09

    A system and method utilizes an image analysis approach for controlling the collection instrument-to-surface distance in a sampling system for use, for example, with mass spectrometric detection. Such an approach involves the capturing of an image of the collection instrument or the shadow thereof cast across the surface and the utilization of line average brightness (LAB) techniques to determine the actual distance between the collection instrument and the surface. The actual distance is subsequently compared to a target distance for re-optimization, as necessary, of the collection instrument-to-surface during an automated surface sampling operation.

  11. Recent developments and future trends in solid phase microextraction techniques towards green analytical chemistry.

    PubMed

    Spietelun, Agata; Marcinkowski, Łukasz; de la Guardia, Miguel; Namieśnik, Jacek

    2013-12-20

    Solid phase microextraction find increasing applications in the sample preparation step before chromatographic determination of analytes in samples with a complex composition. These techniques allow for integrating several operations, such as sample collection, extraction, analyte enrichment above the detection limit of a given measuring instrument and the isolation of analytes from sample matrix. In this work the information about novel methodological and instrumental solutions in relation to different variants of solid phase extraction techniques, solid-phase microextraction (SPME), stir bar sorptive extraction (SBSE) and magnetic solid phase extraction (MSPE) is presented, including practical applications of these techniques and a critical discussion about their advantages and disadvantages. The proposed solutions fulfill the requirements resulting from the concept of sustainable development, and specifically from the implementation of green chemistry principles in analytical laboratories. Therefore, particular attention was paid to the description of possible uses of novel, selective stationary phases in extraction techniques, inter alia, polymeric ionic liquids, carbon nanotubes, and silica- and carbon-based sorbents. The methodological solutions, together with properly matched sampling devices for collecting analytes from samples with varying matrix composition, enable us to reduce the number of errors during the sample preparation prior to chromatographic analysis as well as to limit the negative impact of this analytical step on the natural environment and the health of laboratory employees. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Abnormal urinalysis results are common, regardless of specimen collection technique, in women without urinary tract infections.

    PubMed

    Frazee, Bradley W; Enriquez, Kayla; Ng, Valerie; Alter, Harrison

    2015-06-01

    Voided urinalysis to test for urinary tract infection (UTI) is prone to false-positive results for a number of reasons. Specimens are often collected at triage from women with any abdominal complaint, creating a low UTI prevalence population. Improper collection technique by the patient may affect the result. At least four indices, if positive, can indicate UTI. We examine the impact of voided specimen collection technique on urinalysis indicators of UTI and on urine culture contamination in disease-free women. In this crossover design, 40 menstrual-age female emergency department staff without UTI symptoms collected urine two ways: directly in a cup ("non-clean") and midstream clean catch ("ideal"). Samples underwent standard automated urinalysis and culture. Urinalysis indices and culture contamination were compared. The proportion of abnormal results from samples collected by "non-clean" vs. "ideal" technique, respectively, were: leukocyte esterase (>trace) 50%, 35% (95% confidence interval for difference -6% to 36%); nitrites (any) 2.5%, 2.5% (difference -2.5 to 2.5%); white blood cells (>5/high-powered field [HPF]) 50%, 27.5% (difference 4 to 41%); bacteria (any/HPF) 77.5%, 62.5%, (difference -7 to 37%); epithelial cells (>few) 65%, 30% (difference 13 to 56%); culture contamination (>1000 colony-forming units of commensal or >2 species) 77%, 63% (difference -5 to 35%). No urinalysis index was positively correlated with culture contamination. Contemporary automated urinalysis indices were often abnormal in a disease-free population of women, even using ideal collection technique. In clinical practice, such false-positive results could lead to false-positive UTI diagnosis. Only urine nitrite showed a high specificity. Culture contamination was common regardless of collection technique and was not predicted by urinalysis results. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. GROUND WATER SAMPLING USING LOW-FLOW TECHNIQUES

    EPA Science Inventory

    Obtaining representative ground water samples is important for site assessment and remedial performance monitoring objectives. The sampling device or method used to collect samples from monitoring or compliance well can significantly impact data quality and reliability. Low-flo...

  14. Comet composition and density analyzer

    NASA Technical Reports Server (NTRS)

    Clark, B. C.

    1982-01-01

    Distinctions between cometary material and other extraterrestrial materials (meteorite suites and stratospherically-captured cosmic dust) are addressed. The technique of X-ray fluorescence (XRF) for analysis of elemental composition is involved. Concomitant with these investigations, the problem of collecting representative samples of comet dust (for rendezvous missions) was solved, and several related techniques such as mineralogic analysis (X-ray diffraction), direct analysis of the nucleus without docking (electron macroprobe), dust flux rate measurement, and test sample preparation were evaluated. An explicit experiment concept based upon X-ray fluorescence analysis of biased and unbiased sample collections was scoped and proposed for a future rendezvous mission with a short-period comet.

  15. A perception and manipulation system for collecting rock samples

    NASA Technical Reports Server (NTRS)

    Choi, T.; Delingette, H.; Deluise, M.; Hsin, Y.; Hebert, M.; Ikeuchi, Katsushi

    1991-01-01

    An important part of a planetary exploration mission is to collect and analyze surface samples. As part of the Carnegie Mellon University Ambler Project, researchers are investigating techniques for collecting samples using a robot arm and a range sensor. The aim of this work is to make the sample collection operation fully autonomous. Described here are the components of the experimental system, including a perception module that extracts objects of interest from range images and produces models of their shapes, and a manipulation module that enables the system to pick up the objects identified by the perception module. The system was tested on a small testbed using natural terrain.

  16. Analysis for drugs in saliva and breath

    DOT National Transportation Integrated Search

    1981-09-25

    Collection devices for saliva and breath that involved non-invasive techniques for sample collection were evaluated. Having subjects simply spit into a specially prepared glass vial was found to be an efficient, inexpensive and simple way to collect ...

  17. Soil Sampling Techniques For Alabama Grain Fields

    NASA Technical Reports Server (NTRS)

    Thompson, A. N.; Shaw, J. N.; Mask, P. L.; Touchton, J. T.; Rickman, D.

    2003-01-01

    Characterizing the spatial variability of nutrients facilitates precision soil sampling. Questions exist regarding the best technique for directed soil sampling based on a priori knowledge of soil and crop patterns. The objective of this study was to evaluate zone delineation techniques for Alabama grain fields to determine which method best minimized the soil test variability. Site one (25.8 ha) and site three (20.0 ha) were located in the Tennessee Valley region, and site two (24.2 ha) was located in the Coastal Plain region of Alabama. Tennessee Valley soils ranged from well drained Rhodic and Typic Paleudults to somewhat poorly drained Aquic Paleudults and Fluventic Dystrudepts. Coastal Plain s o i l s ranged from coarse-loamy Rhodic Kandiudults to loamy Arenic Kandiudults. Soils were sampled by grid soil sampling methods (grid sizes of 0.40 ha and 1 ha) consisting of: 1) twenty composited cores collected randomly throughout each grid (grid-cell sampling) and, 2) six composited cores collected randomly from a -3x3 m area at the center of each grid (grid-point sampling). Zones were established from 1) an Order 1 Soil Survey, 2) corn (Zea mays L.) yield maps, and 3) airborne remote sensing images. All soil properties were moderately to strongly spatially dependent as per semivariogram analyses. Differences in grid-point and grid-cell soil test values suggested grid-point sampling does not accurately represent grid values. Zones created by soil survey, yield data, and remote sensing images displayed lower coefficient of variations (8CV) for soil test values than overall field values, suggesting these techniques group soil test variability. However, few differences were observed between the three zone delineation techniques. Results suggest directed sampling using zone delineation techniques outlined in this paper would result in more efficient soil sampling for these Alabama grain fields.

  18. A New Technique for Measuring Concentration Dependence of Self and Collective Diffusivity by using a Single Sample

    NASA Astrophysics Data System (ADS)

    Sirorattanakul, Krittanon; Shen, Chong; Ou-Yang, Daniel

    Diffusivity governs the dynamics of interacting particles suspended in a solvent. At high particle concentration, the interactions between particles become non-negligible, making the values of self and collective diffusivity diverge and concentration-dependent. Conventional methods for measuring this dependency, such as forced Rayleigh scattering, fluorescence correlation spectroscopy (FCS), and dynamic light scattering (DLS) require preparation of multiple samples. We present a new technique to measure this dependency by using only a single sample. Dielectrophoresis (DEP) is used to create concentration gradient in the solution. Across this concentration distribution, we use FCS to measure the concentration-dependent self diffusivity. Then, we switch off DEP to allow the particles to diffuse back to equilibrium. We obtain the time series of concentration distribution from fluorescence microscopy and use them to determine the concentration-dependent collective diffusivity. We compare the experimental results with computer simulations to verify the validity of this technique. Time and spatial resolution limits of FCS and imaging are also analyzed to estimate the limitation of the proposed technique. NSF DMR-0923299, Lehigh College of Arts and Sciences Undergraduate Research Grant, Lehigh Department of Physics, Emulsion Polymers Institute.

  19. Methods for collection and analysis of water samples

    USGS Publications Warehouse

    Rainwater, Frank Hays; Thatcher, Leland Lincoln

    1960-01-01

    This manual contains methods used by the U.S. Geological Survey to collect, preserve, and analyze water samples. Throughout, the emphasis is on obtaining analytical results that accurately describe the chemical composition of the water in situ. Among the topics discussed are selection of sampling sites, frequency of sampling, field equipment, preservatives and fixatives, analytical techniques of water analysis, and instruments. Seventy-seven laboratory and field procedures are given for determining fifty-three water properties.

  20. Database creation, data quality assessment, and geochemical maps (phase V, deliverable 59)—Final report on compilation and validation of geochemical data: Chapter D in Second projet de renforcement institutionnel du secteur minier de la République Islamique de Mauritanie (PRISM-II)

    USGS Publications Warehouse

    Eppinger, Robert G.; Giles, Stuart A.; Lee, Gregory K.; Smith, Steven M.

    2015-01-01

    The geochemical sample media collected by the BGS and BRGM under the PRISM-I contract included rock, sediment, regolith, and soil samples. Details on sample collection procedures are in unpublished reports available from PRISM. These samples were analyzed under PRISM-I contract by ALS Chemex Laboratories using various combinations of modern methods including fire-assay inductively coupled plasma-atomic emission spectrometry (ICPAES) and ICP-mass spectrometry (ICP-MS) for Au; multi-acid digestion, atomic absorption spectroscopy (AAS) for Ag and As; 47-element, four-acid digestion, ICP-MS; 27-element, fouracid digestion, ICP-AES; special four-acid ICP-MS techniques for Pt and B; fire assay followed by ICP-AES for platinum-group elements; whole-rock analyses by wavelength dispersive X-ray fluorescence (XRF); special techniques for loss-on-ignition, inorganic C, and total S; and special ore-grade AAS techniques for Ag, Au, Cu, Ni, Pb, and Zn. Around 30,000 samples were analyzed by at least one technique. However, it is stressed here that: (1) there was no common sample medium collected at all sites, likely due to the vast geological and geomorphologic differences across the country, (2) the sample site distribution is very irregular, likely due in part to access constraints and sand dune cover, and (3) there was no common across-the-board trace element analytical package used for all samples. These three aspects fundamentally affect the ability to produce country-wide geochemical maps of Mauritania. Gold (Au), silver (Ag), and arsenic (As) were the three elements that were most commonly analyzed.

  1. Fit for purpose frozen tissue collections by RNA integrity number-based quality control assurance at the Erasmus MC tissue bank.

    PubMed

    Kap, Marcel; Oomen, Monique; Arshad, Shazia; de Jong, Bas; Riegman, Peter

    2014-04-01

    About 5000 frozen tissue samples are collected each year by the Erasmus Medical Center tissue bank. Two percent of these samples are randomly selected annually for RNA isolation and RNA Integrity Number (RIN) measurement. A similar quality assessment was conducted during centralization of a 20-year-old tissue collection from the cancer institute, a 15-year-old liver sample archive (-80°C), and a 13-year-old clinical pathology frozen biopsy archive (Liquid Nitrogen). Samples were divided into either high-quality (RIN ≥6.5) or low-quality overall categories, or into four "fit-for-purpose" quality groups: RIN <5: not reliable for demanding downstream analysis; 5 ≤RIN <6: suitable for RT-qPCR; 6 ≤RIN <8: suitable for gene array analysis; and RIN ≥8: suitable for all downstream techniques. In general, low RIN values were correlated with fatty, fibrous, pancreatic, or necrotic tissue. When the percentage of samples with RIN ≥6.5 is higher than 90%, the tissue bank performance is adequate. The annual 2011 quality control assessment showed that 90.3% (n=93) of all samples had acceptable RIN values; 97.4% (n=39) of the cancer institute collection had RIN values above 6.5; and 88.6% (n=123) of samples from the liver sample archive collection had RIN values higher than 6.5. As the clinical pathology biopsy collection contained only 58.8% (n=24) acceptable samples, the procurement protocols used for these samples needed immediate evaluation. When the distribution of RIN values of the different collections were compared, no significant differences were found, despite differences in average storage time and temperature. According to the principle of "fit-for-purpose" distribution, the vast majority of samples are considered good enough for most downstream techniques. In conclusion, an annual tissue bank quality control procedure provides useful information on tissue sample quality and sheds light on where and if improvements need to be made.

  2. Biopolymers for sample collection, protection, and preservation.

    PubMed

    Sorokulova, Iryna; Olsen, Eric; Vodyanoy, Vitaly

    2015-07-01

    One of the principal challenges in the collection of biological samples from air, water, and soil matrices is that the target agents are not stable enough to be transferred from the collection point to the laboratory of choice without experiencing significant degradation and loss of viability. At present, there is no method to transport biological samples over considerable distances safely, efficiently, and cost-effectively without the use of ice or refrigeration. Current techniques of protection and preservation of biological materials have serious drawbacks. Many known techniques of preservation cause structural damages, so that biological materials lose their structural integrity and viability. We review applications of a novel bacterial preservation process, which is nontoxic and water soluble and allows for the storage of samples without refrigeration. The method is capable of protecting the biological sample from the effects of environment for extended periods of time and then allows for the easy release of these collected biological materials from the protective medium without structural or DNA damage. Strategies for sample collection, preservation, and shipment of bacterial, viral samples are described. The water-soluble polymer is used to immobilize the biological material by replacing the water molecules within the sample with molecules of the biopolymer. The cured polymer results in a solid protective film that is stable to many organic solvents, but quickly removed by the application of the water-based solution. The process of immobilization does not require the use of any additives, accelerators, or plastifiers and does not involve high temperature or radiation to promote polymerization.

  3. Comparison of three methods of sampling for endometrial cytology in the mare. Preliminary study.

    PubMed

    Defontis, M; Vaillancourt, D; Grand, F X

    2011-01-01

    This prospective study aims to compare three different sampling techniques for the collection of endometrial cytological specimens in the mare: the guarded culture swab, the uterine cytobrush and the low volume uterine flush. The study population consisted of six healthy Standardbred mares in dioestrus. In each mare an acute endometritis was induced by performing a low- volume uterine flush 6days after ovulation using a sterile isotonic solution (lactated Ringer's solution or ViGro™ Complete Flush Solution). Two days after initiating inflammation, samples were collected from each mare using the three compared techniques: the double guarded cotton swab, the uterine cytobrush and the low volume uterine flush. The cytological evaluation of the samples was based on following criteria: the quality and cellularity of the samples and the number of neutrophils recovered. The uterine cytobrush yielded slides of significantly (p=0.02) better quality than the low volume uterine flush. There was no significant difference between the cytobrush and the double guarded swab technique for the quality. There was no difference between techniques in the number of endometrial cells (p=0.55) and neutrophils recovered (p=0.28). Endometrial cytology is a practical method for the diagnosis of acute endometrial inflammation in the mare. Since no difference in the number of neutrophils was found between the three techniques, the choice of the sampling method should be based on other factors such as practicability, costs and disadvantages of each technique.

  4. Motivational Factors and Teachers Commitment in Public Secondary Schools in Mbale Municipality

    ERIC Educational Resources Information Center

    Olurotimi, Ogunlade Joseph; Asad, Kamonges Wahab; Abdulrauf, Abdulkadir

    2015-01-01

    The study investigated the influence of motivational factors on teachers' commitment in public Secondary School in Mbale Municipality. The study employed Cross-sectional survey design. The sampling technique used to select was simple random sampling technique. The instrument used to collect data was a self designed questionnaire. The data…

  5. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    NASA Technical Reports Server (NTRS)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  6. Early detection of disease: The correlation of the volatile organic profiles from patients with upper respiratory infections with subjects of normal profiles

    NASA Technical Reports Server (NTRS)

    Zlatkis, A.

    1979-01-01

    A method is described whereby a transevaporator is used for sampling 60-100 microns of aqueous sample. Volatiles are stripped from the sample either by a stream of helium and collection on a porous polymer, Tenax, or by 0.8 ml of 2-chloropropane and collected on glass beads. The volatiles are thermally desorbed into a precolumn which is connected to a capillary gas chromatographic column for analysis. The technique is shown to be reproducible and suitable for determining chromatographic profiles for a wide variety of sample types. Using a transevaporator sampling technique, the volatile profiles from 70 microns of serum were obtained by capillary column gas chromatography. The complex chromatograms were interpreted by a combination of manual and computer techniques and a two peak ratio method devised for the classification of normal and virus infected sera. Using the K-Nearest Neighbor approach, 85.7 percent of the unknown samples were classified correctly. Some preliminary results indicate the possible use of the method for the assessment of virus susceptibility.

  7. Characterization of Apollo Regolith by X-Ray and Electron Microbeam Techniques: An Analog for Future Sample Return Missions

    NASA Technical Reports Server (NTRS)

    Zeigler, Ryan A.

    2015-01-01

    The Apollo missions collected 382 kg of rock and regolith from the Moon; approximately 1/3 of the sample mass collected was regolith. Lunar regolith consists of well mixed rocks, minerals, and glasses less than 1-centimeter n size. The majority of most surface regolith samples were sieved into less than 1, 1-2, 2-4, and 4-10- millimiter size fractions; a portion of most samples was re-served unsieved. The initial characterization and classification of most Apollo regolith particles was done primarily by binocular microscopy. Optical classification of regolith is difficult because (1) the finest fraction of the regolith coats and obscures the textures of the larger particles, and (b) not all lithologies or minerals are uniquely identifiable optically. In recent years, we have begun to use more modern x-ray beam techniques [1-3], coupled with high resolution 3D optical imaging techniques [4] to characterize Apollo and meteorite samples as part of the curation process. These techniques, particularly in concert with SEM imaging of less than 1-millimeter regolith grain mounts, allow for the rapid characterization of the components within a regolith.

  8. SAMPLING AND ANALYSIS OF MONITORING WELLS AT EPA RESEARCH SITES

    EPA Science Inventory

    I have been asked to speak to the Environmental Science class at ECU on 04-26-04 on the subject of sample collection and analysis of monitoring wells at EPA research sites that I have been involved with. I plan on demonstrating the techniques of well water collection and meter a...

  9. Use of Body-Mounted Cameras to Enhance Data Collection: An Evaluation of Two Arthropod Sampling Techniques.

    PubMed

    Hagler, James R; Thompson, Alison L; Stefanek, Melissa A; Machtley, Scott A

    2018-03-01

    A study was conducted that compared the effectiveness of a sweepnet versus a vacuum suction device for collecting arthropods in cotton. The study differs from previous research in that body-mounted action cameras (B-MACs) were used to record the activity of the person conducting the arthropod collections. The videos produced by the B-MACs were then analyzed with behavioral event recording software to quantify various aspects of the sampling process. The sampler's speed and the number of sampling sweeps or vacuum suctions taken over a fixed distance (12.2 m) of cotton were two of the more significant sampling characteristics quantified for each method. The arthropod counts obtained, combined with the analyses of the videos, enabled us to estimate arthropod sampling efficiency for each technique based on fixed distance, time, and sample unit measurements. Data revealed that the vacuuming was the most precise method for collecting arthropods in the relatively small cotton research plots. However, data also indicates that the sweepnet method would be more efficient for collecting most of the cotton-dwelling arthropod taxa, especially if the sampler could continuously sweep for at least 1 min or ≥80 m (e.g., in larger research plots). The B-MACs are inexpensive and non-cumbersome, the video images generated are outstanding, and they can be archived to provide permanent documentation of a research project. The methods described here could be useful for other types of field-based research to enhance data collection efficiency.

  10. Long-term storage of salivary cortisol samples at room temperature

    NASA Technical Reports Server (NTRS)

    Chen, Yu-Ming; Cintron, Nitza M.; Whitson, Peggy A.

    1992-01-01

    Collection of saliva samples for the measurement of cortisol during space flights provides a simple technique for studying changes in adrenal function due microgravity. In the present work, several methods for preserving saliva cortisol at room temperature were investigated using radioimmunoassays for determining cortisol in saliva samples collected on a saliva-collection device called Salivettes. It was found that a pretreatment of Salivettes with citric acid resulted in preserving more than 85 percent of the salivary cortisol for as long as six weeks. The results correlated well with those for a sample stored in a freezer on an untreated Salivette.

  11. A rapid method for the sampling of atmospheric water vapour for isotopic analysis.

    PubMed

    Peters, Leon I; Yakir, Dan

    2010-01-01

    Analysis of the stable isotopic composition of atmospheric moisture is widely applied in the environmental sciences. Traditional methods for obtaining isotopic compositional data from ambient moisture have required complicated sampling procedures, expensive and sophisticated distillation lines, hazardous consumables, and lengthy treatments prior to analysis. Newer laser-based techniques are expensive and usually not suitable for large-scale field campaigns, especially in cases where access to mains power is not feasible or high spatial coverage is required. Here we outline the construction and usage of a novel vapour-sampling system based on a battery-operated Stirling cycle cooler, which is simple to operate, does not require any consumables, or post-collection distillation, and is light-weight and highly portable. We demonstrate the ability of this system to reproduce delta(18)O isotopic compositions of ambient water vapour, with samples taken simultaneously by a traditional cryogenic collection technique. Samples were collected over 1 h directly into autosampler vials and were analysed by mass spectrometry after pyrolysis of 1 microL aliquots to CO. This yielded an average error of < +/-0.5 per thousand, approximately equal to the signal-to-noise ratio of traditional approaches. This new system provides a rapid and reliable alternative to conventional cryogenic techniques, particularly in cases requiring high sample throughput or where access to distillation lines, slurry maintenance or mains power is not feasible. Copyright 2009 John Wiley & Sons, Ltd.

  12. [Determination of the survival of Trypanosoma evansi in equine blood, using the microhematocrit method].

    PubMed

    Monzón, C M; Jara, G A; Hoyos, C B

    1995-09-01

    The microhaematocrit (MH) technique was used to study the survival of Trypanosoma evansi in blood from two herds of naturally-infected horses. A comparison was made between samples treated with ethylenediaminetetraacetic acid and sodium citrate (alone or with 1% glucose), and sent to the laboratory packed in ice. In general, the number of samples yielding positive results by the MH technique showed the least variation during the first 24-36 h after sample collection. Survival varied with the anticoagulant used, but it declined rapidly from 48 h after collection, although live parasites were still observed in up to 10% of samples until the seventh day. On the basis of the results obtained, the authors recommend the use of sodium citrate in treating equine blood samples for the parasitological diagnosis of T. evansi.

  13. RAT SPERM MOTILITY ANALYSIS: METHODOLOGICAL CONSIDERATIONS

    EPA Science Inventory

    The objective of these studies was to optimize conditions for computer assisted sperm analysis (CASA) of rat epididymal spermatozoa. ethodological issues addressed include sample collection technique, sampling region within the epididymis, type of diluent medium used, and sample ...

  14. Rat sperm motility analysis: methodologic considerations

    EPA Science Inventory

    The objective of these studies was to optimize conditions for computer-assisted sperm analysis (CASA) of rat epididymal spermatozoa. Methodologic issues addressed include sample collection technique, sampling region within the epididymis, type of diluent medium used, and sample c...

  15. Compact, Non-Pneumatic Rock-Powder Samplers

    NASA Technical Reports Server (NTRS)

    Sherrit, Stewart; Bar-Cohen, Yoseph; Badescu, Mircea; Bao, Xiaoqi; Chang, Zensheu; Jones, Christopher; Aldrich, Jack

    2008-01-01

    Tool bits that automatically collect powdered rock, permafrost, or other hard material generated in repeated hammering action have been invented. The present invention pertains to the special case in which it is desired to collect samples in powder form for analysis by x-ray diffraction and possibly other techniques. The present invention eliminates the need for both the mechanical collection equipment and the crushing chamber and the pneumatic collection equipment of prior approaches, so that it becomes possible to make the overall sample-acquisition apparatus more compact.

  16. On-target digestion of collected bacteria for MALDI mass spectrometry.

    PubMed

    Dugas, Alton J; Murray, Kermit K

    2008-10-03

    An on-target protein digestion system was developed for the identification of microorganisms in collected bioaerosols using off-line matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Bacteria analysis techniques based on MALDI-MS were adapted for use with an orthogonal MALDI quadrupole-time-of-flight mass spectrometer. Bioaerosols were generated using a pneumatic nebulizer and infused into a chamber for sampling. An Andersen N6 single-stage impactor was used to collect the bioaerosols on a MALDI target. On-target digestion was carried out inside temporary mini-wells placed over the impacted samples. The wells served as miniature reactors for proteolysis. Collected test aerosol particles containing the protein cytochrome c and E. coli bacteria were proteolyzed in situ using trypsin or cyanogen bromide. A total of 19 unique proteins were identified for E. coli. Using the TOF-MS spectra of the digested samples, peptide mass mapping was performed using the MASCOT search engine and an iterative search technique.

  17. Differences in sampling techniques on total post-mortem tryptase.

    PubMed

    Tse, R; Garland, J; Kesha, K; Elstub, H; Cala, A D; Ahn, Y; Stables, S; Palmiere, C

    2018-05-01

    The measurement of mast cell tryptase is commonly used to support the diagnosis of anaphylaxis. In the post-mortem setting, the literature recommends sampling from peripheral blood sources (femoral blood) but does not specify the exact sampling technique. Sampling techniques vary between pathologists, and it is unclear whether different sampling techniques have any impact on post-mortem tryptase levels. The aim of this study is to compare the difference in femoral total post-mortem tryptase levels between two sampling techniques. A 6-month retrospective study comparing femoral total post-mortem tryptase levels between (1) aspirating femoral vessels with a needle and syringe prior to evisceration and (2) femoral vein cut down during evisceration. Twenty cases were identified, with three cases excluded from analysis. There was a statistically significant difference (paired t test, p < 0.05) between mean post-mortem tryptase by aspiration (10.87 ug/L) and by cut down (14.15 ug/L). The mean difference between the two methods was 3.28 ug/L (median, 1.4 ug/L; min, - 6.1 ug/L; max, 16.5 ug/L; 95% CI, 0.001-6.564 ug/L). Femoral total post-mortem tryptase is significantly different, albeit by a small amount, between the two sampling methods. The clinical significance of this finding and what factors may contribute to it are unclear. When requesting post-mortem tryptase, the pathologist should consider documenting the exact blood collection site and method used for collection. In addition, blood samples acquired by different techniques should not be mixed together and should be analyzed separately if possible.

  18. Techniques to Collect and Analyze the Cognitive Map Knowledge of Persons with Visual Impairment or Blindness: Issues of Validity.

    ERIC Educational Resources Information Center

    Kitchin, R. M.; Jacobson, R. D.

    1997-01-01

    Assesses techniques used by researchers to collect and analyze data on how people with visual impairments or blindness learn, understand, and think about geographic space. Recommendations are made for increasing the validity of studies, including the use of multiple, mutually supportive tests; larger samples; and real-world environments.…

  19. Wetlands Research Program. Evaluation of Methods for Sampling Vegetation and Delineating Wetlands Transition Zones in Southern Louisiana, January 1979-May 1981.

    DTIC Science & Technology

    1983-10-01

    sites should be collected and correlated to vegetational response through ordination or factor analysis techniques. 3. If site-specific methods are...specified number of samples is collected . If the 40 ."l ’ - - - .. -’-. - : -. .~ -, .4 .- . -.- , - ...... rb. . o* . -.% o - .- * .-.- v- . J...only, although the data collected were sufficient for determination of such parameters as density, cover, frequency, basal area, and importance value

  20. Collecting, preparing, crossdating, and measuring tree increment cores

    USGS Publications Warehouse

    Phipps, R.L.

    1985-01-01

    Techniques for collecting and handling increment tree cores are described. Procedures include those for cleaning and caring for increment borers, extracting the sample from a tree, core surfacing, crossdating, and measuring. (USGS)

  1. Reconnaissance techniques for determining soil-gas radon concentrations: an example from Prince Georges County, Maryland

    USGS Publications Warehouse

    Reimer, G.M.

    1990-01-01

    Radon reconnaissance requires some special considerations because a large area must be covered in a short period of time and analyses must be made soon after collection because of Rn decay. A simple approach to collection and field analysis consists of a small-diameter probe pounded into the ground to a depth of at least 0.75 m. Analysis is by an alpha-scintillometer. Soil-gas samples collected along a traverse in Prince Georges County, Maryland, demonstrates the utility of the technique. The reconnaissance sampling revealed Rn soil-gas concentrations of up to 2500 pCi/L (picocuries per liter) indicating that the potential exists for indoor accumulations in excess of 4 pCi/L. -from Author

  2. A comparison of ruminal or reticular digesta sampling as an alternative to sampling from the omasum of lactating dairy cows.

    PubMed

    Fatehi, F; Krizsan, S J; Gidlund, H; Huhtanen, P

    2015-05-01

    The objective of this study was to develop and compare techniques for determining nutrient flow based on digesta samples collected from the reticulum or rumen of lactating dairy cows with estimates generated by the omasal sampling technique. Pre-experimental method development suggested, after comparing with the particle size distribution of feces, application of primary sieving of ruminal and reticular digesta from lactating cows through an 11.6-mm sieve, implying that digesta particles smaller than this were eligible to flow out of the rumen. For flow measurements at the different sampling sites 4 multiparous, lactating Nordic Red cows fitted with ruminal cannulas were used in a Latin square design with 4 dietary treatments, in which crimped barley was replaced with 3 incremental levels of protein supplementation of canola meal. Digesta was collected from the rumen, reticulum, and omasum to represent a 24-h feeding cycle. Nutrient flow was calculated using the reconstitution system based on Cr, Yb, and indigestible neutral detergent fiber and using (15)N as microbial marker. Large and small particles and the fluid phase were recovered from digesta collected at all sampling sites. Bacterial samples were isolated from the digesta collected from the omasum. Several differences existed for digesta composition, nutrient flows, and estimates of ruminal digestibility among the 3 different sampling sites. Sampling site × diet interactions were not significant. The estimated flows of DM, potentially digestible neutral detergent fiber, nonammonia N, and microbial N were significantly different between all sampling sites. However, the difference between DM flow based on sampling from the reticulum and the omasum was small (0.13kg/d greater in the omasum). The equality between the reticulum and the omasum as sampling sites was supported by the following regression: omasal DM flow=0.37 (±0.649) + 0.94 (±0.054) reticular DM flow (R(2)=0.96 and root mean square error=0.438kg/d). More deviating nutrient-flow estimates when sampling digesta from the rumen than the reticulum compared with the omasum suggested that sampling from the reticulum is the most promising alternative to the omasal sampling technique. To definitively promote sampling from the reticulum as an alternative to the omasal sampling technique, more research is needed to determine selection criteria of reticular digesta for accurate and precise flow estimates across a range of diets. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. Influence of size-fractioning techniques on concentrations of selected trace metals in bottom materials from two streams in northeastern Ohio

    USGS Publications Warehouse

    Koltun, G.F.; Helsel, Dennis R.

    1986-01-01

    Identical stream-bottom material samples, when fractioned to the same size by different techniques, may contain significantly different trace-metal concentrations. Precision of techniques also may differ, which could affect the ability to discriminate between size-fractioned bottom-material samples having different metal concentrations. Bottom-material samples fractioned to less than 0.020 millimeters by means of three common techniques (air elutriation, sieving, and settling) were analyzed for six trace metals to determine whether the technique used to obtain the desired particle-size fraction affects the ability to discriminate between bottom materials having different trace-metal concentrations. In addition, this study attempts to assess whether median trace-metal concentrations in size-fractioned bottom materials of identical origin differ depending on the size-fractioning technique used. Finally, this study evaluates the efficiency of the three size-fractioning techniques in terms of time, expense, and effort involved. Bottom-material samples were collected at two sites in northeastern Ohio: One is located in an undeveloped forested basin, and the other is located in a basin having a mixture of industrial and surface-mining land uses. The sites were selected for their close physical proximity, similar contributing drainage areas, and the likelihood that trace-metal concentrations in the bottom materials would be significantly different. Statistically significant differences in the concentrations of trace metals were detected between bottom-material samples collected at the two sites when the samples had been size-fractioned by means of air elutriation or sieving. Statistical analyses of samples that had been size fractioned by settling in native water were not measurably different in any of the six trace metals analyzed. Results of multiple comparison tests suggest that differences related to size-fractioning technique were evident in median copper, lead, and iron concentrations. Technique-related differences in copper concentrations most likely resulted from contamination of air-elutriated samples by a feed tip on the elutriator apparatus. No technique-related differences were observed in chromium, manganese, or zinc concentrations. Although air elutriation was the most expensive sizefractioning technique investigated, samples fractioned by this technique appeared to provide a superior level of discrimination between metal concentrations present in the bottom materials of the two sites. Sieving was an adequate lower-cost but more laborintensive alternative.

  4. Determination of formaldehyde by HPLC as the DNPH derivative following high-volume air sampling onto bisulfite-coated cellulose filters

    NASA Astrophysics Data System (ADS)

    de Andrade, Jailson B.; Tanner, Roger L.

    A method is described for the specific collection of formaldehyde as hydroxymethanesulfonate on bisulfate-coated cellulose filters. Following extraction in aqueous acid and removal on unreacted bisulfite, the hydroxymethanesulfonate is decomposed by base, and HCHO is determined by DNPH (2,4-dinitrophenylhydrazine) derivatization and HPLC. Since the collection efficiency for formaldehyde is moderately high even when sampling ambient air at high-volume flow rates, a limit of detection of 0.2 ppbv is achieved with 30 min sampling times. Interference from acetaldehyde co-collected as 1-hydroxyethanesulfonate is <5% using this procedure. The technique shows promise for both short-term airborne sampling, and as a means of collecting mg-sized samples of HCHO on an inorganic matrix for carbon isotopic analyses.

  5. Evaluation of environmental sampling methods for detection of Salmonella enterica in a large animal veterinary hospital.

    PubMed

    Goeman, Valerie R; Tinkler, Stacy H; Hammac, G Kenitra; Ruple, Audrey

    2018-04-01

    Environmental surveillance for Salmonella enterica can be used for early detection of contamination; thus routine sampling is an integral component of infection control programs in hospital environments. At the Purdue University Veterinary Teaching Hospital (PUVTH), the technique regularly employed in the large animal hospital for sample collection uses sterile gauze sponges for environmental sampling, which has proven labor-intensive and time-consuming. Alternative sampling methods use Swiffer brand electrostatic wipes for environmental sample collection, which are reportedly effective and efficient. It was hypothesized that use of Swiffer wipes for sample collection would be more efficient and less costly than the use of gauze sponges. A head-to-head comparison between the 2 sampling methods was conducted in the PUVTH large animal hospital and relative agreement, cost-effectiveness, and sampling efficiency were compared. There was fair agreement in culture results between the 2 sampling methods, but Swiffer wipes required less time and less physical effort to collect samples and were more cost-effective.

  6. Use of an ultra-clean sampling technique with inductively coupled plasma-mass spectrometry to determine trace-element concentrations in water from the Kirkwood-Cohansey Aquifer system, coastal plain, New Jersey

    USGS Publications Warehouse

    Ivahnenko, Tamara; Szabo, Zoltan; Hall, G.S.

    1996-01-01

    Water samples were collected during 1993 from 22 public supply wells screened in the Kirkwood-Cohansey aquifer system; concentrations of 18 trace elements were determined primarily by using inductively coupled plasma-mass spectrometry (ICP-MS) techniques, though graphite furnace atomic adsorption, hydride generation, and cold- vapor flameless atomic adsorption techniques were used for thallium, arsenic, and mercury, respectively, at the U.S. Geological Survey (USGS) National Water Quality Laboratory (NWQL). In addition, laboratory measurements of alkalinity and turbidity were made. The ground-water samples were collected by using ultra-clean sampling protocols developed by the USGS for collecting ground-water samples in areas with water containing low concentrations of trace elements. This technique is based on recently gained experience in sampling surface water for these elements. Field parameters (water temperature, specific conductance, pH, and dissolved-oxygen concentration) were monitored prior to sample collection. Three equipment blanks were collected to ensure that low-level trace-element contamination did not occur during sample collection. One split sample and a commercially- prepared reference standard were submitted to the NWQL o evaluate laboratory precision and accuracy, respectively. Trace-element concentrations in 10 sample splits and one equipment blank were also determined at the Rutgers University Chemistry Department laboratory. Results of the ICP-MS analyses and cold vapor flameless atomic absorption indicated that five trace elements-- cobalt, copper, lead, mercury, and nickel--were detectable in low concentrations (<0.1-29 mg/L) in most of the samples from the 22 wells, and four elements--aluminum, barium, manganese and zinc--were detected in higher concentrations than the other elements (30-710 mg/L for aluminum; 4-180 mg/L for barium, manganese, and zinc). The remaining nine trace elements were present in concentrations consistently lower than the minimum reporting limit. Turbidity was low (less than 1 nephelometric turbidity unit (NTU)), indicating that the trace-element concentrations were present in the dissolved phase and ideally would be reproducible in the absence of highly variable concentrations of particulates. The concentration of lead in one sample exceeded the U.S. Environmental Protection Agency (USEPA) action level of 15 mg/L; concentrations ranged from <1 to 16 mg/L. Mercury was frequently detected; concentrations ranged from <0.1 to 1.1 mg/L but did not exceed the USEPA maximum contaminant level. Results of analyses of the equipment blanks indicated that samples collected by using the new ultra-clean sampling protocols were free of low-level (< 1mg/L) trace-element contamination. The analysis of the split sample sent to the NWQL had a difference of 5 percent or less for all constituents except aluminum, for which the analysis had a difference of 10 percent. Results of ICP-MS analyses of split water samples sent to the Rutgers University Chemistry Department laboratory were, in general, in good agreement (within 10 percent) with those of the NWQL. Results of the analysis of the commercial standard agreed (within 5 percent) with the known concentrations of the trace elements. The quality-assurance data (three blanks, one split sample, and one standard), although not statistically evaluated because of the small data set, indicate that the measured trace-element concentrations are precise and accurate and that the samples were free of contamination at the microgram-per-liter level of contamination.

  7. Detection of the urban release of a bacillus anthracis simulant by air sampling.

    PubMed

    Garza, Alexander G; Van Cuyk, Sheila M; Brown, Michael J; Omberg, Kristin M

    2014-01-01

    In 2005 and 2009, the Pentagon Force Protection Agency (PFPA) staged deliberate releases of a commercially available organic pesticide containing Bacillus amyloliquefaciens to evaluate PFPA's biothreat response protocols. In concert with, but independent of, these releases, the Department of Homeland Security sponsored experiments to evaluate the efficacy of commonly employed air and surface sampling techniques for detection of an aerosolized biological agent. High-volume air samplers were placed in the expected downwind plume, and samples were collected before, during, and after the releases. Environmental surface and personal air samples were collected in the vicinity of the high-volume air samplers hours after the plume had dispersed. The results indicate it is feasible to detect the release of a biological agent in an urban area both during and after the release of a biological agent using high-volume air and environmental sampling techniques.

  8. A hybrid LIBS-Raman system combined with chemometrics: an efficient tool for plastic identification and sorting.

    PubMed

    Shameem, K M Muhammed; Choudhari, Khoobaram S; Bankapur, Aseefhali; Kulkarni, Suresh D; Unnikrishnan, V K; George, Sajan D; Kartha, V B; Santhosh, C

    2017-05-01

    Classification of plastics is of great importance in the recycling industry as the littering of plastic wastes increases day by day as a result of its extensive use. In this paper, we demonstrate the efficacy of a combined laser-induced breakdown spectroscopy (LIBS)-Raman system for the rapid identification and classification of post-consumer plastics. The atomic information and molecular information of polyethylene terephthalate, polyethylene, polypropylene, and polystyrene were studied using plasma emission spectra and scattered signal obtained in the LIBS and Raman technique, respectively. The collected spectral features of the samples were analyzed using statistical tools (principal component analysis, Mahalanobis distance) to categorize the plastics. The analyses of the data clearly show that elemental information and molecular information obtained from these techniques are efficient for classification of plastics. In addition, the molecular information collected via Raman spectroscopy exhibits clearly distinct features for the transparent plastics (100% discrimination), whereas the LIBS technique shows better spectral feature differences for the colored samples. The study shows that the information obtained from these complementary techniques allows the complete classification of the plastic samples, irrespective of the color or additives. This work further throws some light on the fact that the potential limitations of any of these techniques for sample identification can be overcome by the complementarity of these two techniques. Graphical Abstract ᅟ.

  9. Evolution of efficient methods to sample lead sources, such as house dust and hand dust, in the homes of children

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Que Hee, S.S.; Peace, B.; Clark, C.S.

    Efficient sampling methods to recover lead-containing house dust and hand dust have been evolved so that sufficient lead is collected for analysis and to ensure that correlational analyses linking these two parameters to blood lead are not dependent on the efficiency of sampling. Precise collection of loose house dust from a 1-unit area (484 cmS) with a Tygon or stainless steel sampling tube connected to a portable sampling pump (1.2 to 2.5 liters/min) required repetitive sampling (three times). The Tygon tube sampling technique for loose house dust <177 m in diameter was around 72% efficient with respect to dust weightmore » and lead collection. A representative house dust contained 81% of its total weight in this fraction. A single handwipe for applied loose hand dust was not acceptably efficient or precise, and at least three wipes were necessary to achieve recoveries of >80% of the lead applied. House dusts of different particle sizes <246 m adhered equally well to hands. Analysis of lead-containing material usually required at least three digestions/decantations using hot plate or microwave techniques to allow at least 90% of the lead to be recovered. It was recommended that other investigators validate their handwiping, house dust sampling, and digestion techniques to facilitate comparison of results across studies. The final methodology for the Cincinnati longitudinal study was three sampling passes for surface dust using a stainless steel sampling tube; three microwave digestion/decantations for analysis of dust and paint; and three wipes with handwipes with one digestion/decantation for the analysis of six handwipes together.« less

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hurley, D.F.; Whitehouse, J.M.

    A dedicated low-flow groundwater sample collection system was designed for implementation in a post-closure ACL monitoring program at the Yaworski Lagoon NPL site in Canterbury, Connecticut. The system includes dedicated bladder pumps with intake ports located in the screened interval of the monitoring wells. This sampling technique was implemented in the spring of 1993. The system was designed to simultaneously obtain samples directly from the screened interval of nested wells in three distinct water bearing zones. Sample collection is begun upon stabilization of field parameters. Other than line volume, no prior purging of the well is required. It was foundmore » that dedicated low-flow sampling from the screened interval provides a method of representative sample collection without the bias of suspended solids introduced by traditional techniques of pumping and bailing. Analytical data indicate that measured chemical constituents are representative of groundwater migrating through the screened interval. Upon implementation of the low-flow monitoring system, analytical results exhibited a decrease in concentrations of some organic compounds and metals. The system has also proven to be a cost effective alternative to pumping and bailing which generate large volumes of purge water requiring containment and disposal.« less

  11. Enabling Technologies for Point and Remote Sensing of Chemical and Biological Agents Using Surface Enhanced Raman Scattering (SERS) Techniques

    DTIC Science & Technology

    2009-09-01

    silver colloid. .........................15 Figure 10. SEM images of various Bacillus spores on (a) fabricated substrate, (b) Klarite substrate...Figure 12. Comparison of SERS spectra from several Bacillus spore samples collected on Klarite substrates collected on Renishaw system...19 Figure 13. Comparison of SERS spectra from several Bacillus spore samples on FON

  12. Evaluation of Nonpoint-Source Contamination, Wisconsin: Selected Topics for Water Year 1995

    USGS Publications Warehouse

    Owens, D.W.; Corsi, Steven R.; Rappold, K.F.

    1997-01-01

    The objective of the watershed-management evaluation monitoring program in Wisconsin is to evaluate the effectiveness of best-management practices (BMP's) for controlling nonpoint-source contamination in eight rural and four urban watersheds. This report, the fourth in an annual series of reports, presents a summary of the data collected for the program by the U.S. Geological Survey and the results of several detailed analyses of the data. To complement assessments of water quality, a land-use and BMP inventory is ongoing for 12 evaluation monitoring projects to track nonpoint sources of contamination in each watershed and to document implementation of BMP's that were designed to cause changes in the water quality of streams. Each year, updated information is gathered, mapped, and stored in a geographic-information-system data base. Summaries of land-use, BMP implementation, and water-quality data collected during water years 1989-95 are presented. Storm loads, snowmelt-period loads, and annual loads of suspended sediment and total phosphorus are summarized for eight rural sites. Storm-load data for suspended solids, total phosphorus, total recoverable lead, copper, zinc, and cadmium are summarized for four urban sites. Quality-assurance and quality-control (QA/QC) samples were collected at the eight rural sites to evaluate inorganic sample contamination and at one urban site to evaluate sample-collection and filtration techniques for polycyclic aromatic hydrocarbons (PAR's). Some suspended solids and fecal coliform contamination was detected at the rural sites. Corrective actions will be taken to address this contamination. Evaluation of PAR sample-collection techniques did not uncover any deficiencies, but the small amount of data collected was not sufficient to draw any definite conclusions. Evaluation of PAR filtration techniques indicate that water-sample filtration with O.7-um glass-fiber filters in an aluminum filter unit does not result in significant loss of PAR.

  13. Mossbauer spectrometer radiation detector

    NASA Technical Reports Server (NTRS)

    Singh, J. J. (Inventor)

    1973-01-01

    A Mossbauer spectrometer with high efficiencies in both transmission and backscattering techniques is described. The device contains a sodium iodide crystal for detecting radiation caused by the Mossbauer effect, and two photomultipliers to collect the radiation detected by the crystal. When used in the transmission technique, the sample or scatterer is placed between the incident radiation source and the detector. When used in a backscattering technique, the detector is placed between the incident radiation source and the sample of scatterer such that the incident radiation will pass through a hole in the crystal and strike the sample. Diagrams of the instrument are provided.

  14. Standardization of proton-induced x-ray emission technique for analysis of thick samples

    NASA Astrophysics Data System (ADS)

    Ali, Shad; Zeb, Johar; Ahad, Abdul; Ahmad, Ishfaq; Haneef, M.; Akbar, Jehan

    2015-09-01

    This paper describes the standardization of the proton-induced x-ray emission (PIXE) technique for finding the elemental composition of thick samples. For the standardization, three different samples of standard reference materials (SRMs) were analyzed using this technique and the data were compared with the already known data of these certified SRMs. These samples were selected in order to cover the maximum range of elements in the periodic table. Each sample was irradiated for three different values of collected beam charges at three different times. A proton beam of 2.57 MeV obtained using 5UDH-II Pelletron accelerator was used for excitation of x-rays from the sample. The acquired experimental data were analyzed using the GUPIXWIN software. The results show that the SRM data and the data obtained using the PIXE technique are in good agreement.

  15. More Poop, More Precision: Improving Epidemiologic Surveillance of Soil-Transmitted Helminths with Multiple Fecal Sampling using the Kato-Katz Technique.

    PubMed

    Liu, Chengfang; Lu, Louise; Zhang, Linxiu; Bai, Yu; Medina, Alexis; Rozelle, Scott; Smith, Darvin Scott; Zhou, Changhai; Zang, Wei

    2017-09-01

    Soil-transmitted helminths, or parasitic intestinal worms, are among the most prevalent and geographically widespread parasitic infections in the world. Accurate diagnosis and quantification of helminth infection are critical for informing and assessing deworming interventions. The Kato-Katz thick smear technique, the most widely used laboratory method to quantitatively assess infection prevalence and infection intensity of helminths, has often been compared with other methods. Only a few small-scale studies, however, have considered ways to improve its diagnostic sensitivity. This study, conducted among 4,985 school-age children in an area of rural China with moderate prevalence of helminth infection, examines the effect on diagnostic sensitivity of the Kato-Katz technique when two fecal samples collected over consecutive days are examined and compared with a single sample. A secondary aim was to consider cost-effectiveness by calculating an estimate of the marginal costs of obtaining an additional fecal sample. Our findings show that analysis of an additional fecal sample led to increases of 23%, 26%, and 100% for Ascaris lumbricoides, Trichuris trichiura , and hookworm prevalence, respectively. The cost of collecting a second fecal sample for our study population was approximately USD4.60 per fecal sample. Overall, the findings suggest that investing 31% more capital in fecal sample collection prevents an underestimation of prevalence by about 21%, and hence improves the diagnostic sensitivity of the Kato-Katz method. Especially in areas with light-intensity infections of soil-transmitted helminths and limited public health resources, more accurate epidemiological surveillance using multiple fecal samples will critically inform decisions regarding infection control and prevention.

  16. Analysis for drug in saliva and breath

    DOT National Transportation Integrated Search

    1981-09-25

    Collection devices for saliva and breath that involved non-invasive : techniques for sample collection were evaluated. Having subjects simply : spit into a specially prepared glass vial was found to be an efficient, : inexpensive and simple way to co...

  17. On-chip collection of particles and cells by AC electroosmotic pumping and dielectrophoresis using asymmetric microelectrodes.

    PubMed

    Melvin, Elizabeth M; Moore, Brandon R; Gilchrist, Kristin H; Grego, Sonia; Velev, Orlin D

    2011-09-01

    The recent development of microfluidic "lab on a chip" devices requiring sample sizes <100 μL has given rise to the need to concentrate dilute samples and trap analytes, especially for surface-based detection techniques. We demonstrate a particle collection device capable of concentrating micron-sized particles in a predetermined area by combining AC electroosmosis (ACEO) and dielectrophoresis (DEP). The planar asymmetric electrode pattern uses ACEO pumping to induce equal, quadrilateral flow directed towards a stagnant region in the center of the device. A number of system parameters affecting particle collection efficiency were investigated including electrode and gap width, chamber height, applied potential and frequency, and number of repeating electrode pairs and electrode geometry. The robustness of the on-chip collection design was evaluated against varying electrolyte concentrations, particle types, and particle sizes. These devices are amenable to integration with a variety of detection techniques such as optical evanescent waveguide sensing.

  18. 7 CFR 3600.3 - Functions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    .... agricultural and rural economy. (2) Administering a methodological research program to improve agricultural... design and data collection methodologies to the agricultural statistics program. Major functions include...) Designing, testing, and establishing survey techniques and standards, including sample design, sample...

  19. 7 CFR 3600.3 - Functions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    .... agricultural and rural economy. (2) Administering a methodological research program to improve agricultural... design and data collection methodologies to the agricultural statistics program. Major functions include...) Designing, testing, and establishing survey techniques and standards, including sample design, sample...

  20. 7 CFR 3600.3 - Functions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    .... agricultural and rural economy. (2) Administering a methodological research program to improve agricultural... design and data collection methodologies to the agricultural statistics program. Major functions include...) Designing, testing, and establishing survey techniques and standards, including sample design, sample...

  1. 7 CFR 3600.3 - Functions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    .... agricultural and rural economy. (2) Administering a methodological research program to improve agricultural... design and data collection methodologies to the agricultural statistics program. Major functions include...) Designing, testing, and establishing survey techniques and standards, including sample design, sample...

  2. 7 CFR 3600.3 - Functions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    .... agricultural and rural economy. (2) Administering a methodological research program to improve agricultural... design and data collection methodologies to the agricultural statistics program. Major functions include...) Designing, testing, and establishing survey techniques and standards, including sample design, sample...

  3. Coupling Meteorology, Metal Concentrations, and Pb Isotopes for Source Attribution in Archived Precipitation Samples

    EPA Science Inventory

    A technique that couples lead (Pb) isotopes and multi-element concentrations with meteorological analysis was used to assess source contributions to precipitation samples at the Bondville, Illinois USA National Trends Network (NTN) site. Precipitation samples collected over a 16 ...

  4. GAS CHROMATOGRAPHIC TECHNIQUES FOR THE MEASUREMENT OF ISOPRENE IN AIR

    EPA Science Inventory

    The chapter discusses gas chromatographic techniques for measuring isoprene in air. Such measurement basically consists of three parts: (1) collection of sufficient sample volume for representative and accurate quantitation, (2) separation (if necessary) of isoprene from interfer...

  5. Major- and Trace-Element Concentrations in Rock Samples Collected in 2005 from the Taylor Mountains 1:250,000-scale Quadrangle, Alaska

    USGS Publications Warehouse

    Klimasauskas, Edward P.; Miller, Marti L.; Bradley, Dwight C.; Bundtzen, Tom K.; Hudson, Travis L.

    2006-01-01

    The data consist of major- and minor-element concentrations for rock samples collected during 2005 by the U.S. Geological Survey. Samples were analyzed by fire assay (Au, Pd, Pt), cold vapor atomic absorption spectroscopy (Hg), and the inductively coupled plasma mass spectrometry (ICPMS) 10 and 42 element methods. For details of sample preparation and analytical techniques see USGS Open File Report 02-0223 (Analytical methods for chemical analysis of geologic and other materials, U.S. Geological Survey), available at .

  6. Whole-rock and glass major-element geochemistry of Kilauea Volcano, Hawaii, near-vent eruptive products: September 1994 through September 2001

    USGS Publications Warehouse

    Thornber, Carl R.; Sherrod, David R.; Siems, David F.; Heliker, Christina C.; Meeker, Gregory P.; Oscarson, Robert L.; Kauahikaua, James P.

    2002-01-01

    This report presents major-element geochemical data for glasses and whole-rock aliquots among 523 lava samples collected near the vent on Kilauea's east rift zone between September 1994 and October 2001. Information on sample collection, analysis techniques and analytical standard reproducibility are presented as a PDF file, which also includes a detailed explantion of the categories of sample information presented in the database spreadsheet. The sample database is downloadable as a separate Microsoft Excel file.

  7. Potential concerns with analytical Methods Used for the detection of Batrachochytrium salamandrivorans from archived DNA of amphibian swab samples, Oregon, USA

    USGS Publications Warehouse

    Iwanowicz, Deborah; Olson, Deanna H.; Adams, Michael J.; Adams, Cynthia; Anderson, Chauncey; Blaustein, Andrew R; Densmore, Christine L.; Figiel, Chester; Schill, William B.; Chestnut, Tara

    2017-01-01

    Taxonomic identification of pollen has historically been accomplished via light microscopy but requires specialized knowledge and reference collections, particularly when identification to lower taxonomic levels is necessary. Recently, next-generation sequencing technology has been used as a cost-effective alternative for identifying bee-collected pollen; however, this novel approach has not been tested on a spatially or temporally robust number of pollen samples. Here, we compare pollen identification results derived from light microscopy and DNA sequencing techniques with samples collected from honey bee colonies embedded within a gradient of intensive agricultural landscapes in the Northern Great Plains throughout the 2010–2011 growing seasons. We demonstrate that at all taxonomic levels, DNA sequencing was able to discern a greater number of taxa, and was particularly useful for the identification of infrequently detected species. Importantly, substantial phenological overlap did occur for commonly detected taxa using either technique, suggesting that DNA sequencing is an appropriate, and enhancing, substitutive technique for accurately capturing the breadth of bee-collected species of pollen present across agricultural landscapes. We also show that honey bees located in high and low intensity agricultural settings forage on dissimilar plants, though with overlap of the most abundantly collected pollen taxa. We highlight practical applications of utilizing sequencing technology, including addressing ecological issues surrounding land use, climate change, importance of taxa relative to abundance, and evaluating the impact of conservation program habitat enhancement efforts.

  8. The Problem of Sample Contamination in a Fluvial Geochemistry Research Experience for Undergraduates.

    ERIC Educational Resources Information Center

    Andersen, Charles B.

    2001-01-01

    Introduces the analysis of a river as an excellent way to teach geochemical techniques because of the relative ease of sample collection and speed of sample analysis. Focuses on the potential sources of sample contamination during sampling, filtering, and bottle cleaning processes, and reviews methods to reduce and detect contamination. Includes…

  9. Fitting distributions to microbial contamination data collected with an unequal probability sampling design.

    PubMed

    Williams, M S; Ebel, E D; Cao, Y

    2013-01-01

    The fitting of statistical distributions to microbial sampling data is a common application in quantitative microbiology and risk assessment applications. An underlying assumption of most fitting techniques is that data are collected with simple random sampling, which is often times not the case. This study develops a weighted maximum likelihood estimation framework that is appropriate for microbiological samples that are collected with unequal probabilities of selection. A weighted maximum likelihood estimation framework is proposed for microbiological samples that are collected with unequal probabilities of selection. Two examples, based on the collection of food samples during processing, are provided to demonstrate the method and highlight the magnitude of biases in the maximum likelihood estimator when data are inappropriately treated as a simple random sample. Failure to properly weight samples to account for how data are collected can introduce substantial biases into inferences drawn from the data. The proposed methodology will reduce or eliminate an important source of bias in inferences drawn from the analysis of microbial data. This will also make comparisons between studies and the combination of results from different studies more reliable, which is important for risk assessment applications. © 2012 No claim to US Government works.

  10. Sources of variability in collection and preparation of paint and lead-coating samples.

    PubMed

    Harper, S L; Gutknecht, W F

    2001-06-01

    Chronic exposure of children to lead (Pb) can result in permanent physiological impairment. Since surfaces coated with lead-containing paints and varnishes are potential sources of exposure, it is extremely important that reliable methods for sampling and analysis be available. The sources of variability in the collection and preparation of samples were investigated to improve the performance and comparability of methods and to ensure that data generated will be adequate for its intended use. Paint samples of varying sizes (areas and masses) were collected at different locations across a variety of surfaces including metal, plaster, concrete, and wood. A variety of grinding techniques were compared. Manual mortar and pestle grinding for at least 1.5 min and mechanized grinding techniques were found to generate similar homogenous particle size distributions required for aliquots as small as 0.10 g. When 342 samples were evaluated for sample weight loss during mortar and pestle grinding, 4% had 20% or greater loss with a high of 41%. Homogenization and sub-sampling steps were found to be the principal sources of variability related to the size of the sample collected. Analysis of samples from different locations on apparently identical surfaces were found to vary by more than a factor of two both in Pb concentration (mg cm-2 or %) and areal coating density (g cm-2). Analyses of substrates were performed to determine the Pb remaining after coating removal. Levels as high as 1% Pb were found in some substrate samples, corresponding to more than 35 mg cm-2 Pb. In conclusion, these sources of variability must be considered in development and/or application of any sampling and analysis methodologies.

  11. Pickett angles and Cremer-Pople coordinates as collective variables for the enhanced sampling of six-membered ring conformations

    NASA Astrophysics Data System (ADS)

    Sega, M.; Autieri, E.; Pederiva, F.

    2011-01-01

    Although completely equivalent for the description of puckered ring conformers, the two popular coordinates sets of Strauss-Pickett dihedral angles and Cremer-Pople spherical coordinates are shown to have contrasting features when employed as collective variables in free-energy calculations with accelerated sampling techniques. Results from a 100 ns molecular dynamics simulation at conformational equilibrium and from combined metadynamics/umbrella sampling calculations of glucose are exploited to elucidate these differences.

  12. Low-dose fixed-target serial synchrotron crystallography.

    PubMed

    Owen, Robin L; Axford, Danny; Sherrell, Darren A; Kuo, Anling; Ernst, Oliver P; Schulz, Eike C; Miller, R J Dwayne; Mueller-Werkmeister, Henrike M

    2017-04-01

    The development of serial crystallography has been driven by the sample requirements imposed by X-ray free-electron lasers. Serial techniques are now being exploited at synchrotrons. Using a fixed-target approach to high-throughput serial sampling, it is demonstrated that high-quality data can be collected from myoglobin crystals, allowing room-temperature, low-dose structure determination. The combination of fixed-target arrays and a fast, accurate translation system allows high-throughput serial data collection at high hit rates and with low sample consumption.

  13. Field Methods and Sample Collection Techniques for the Surveillance of West Nile Virus in Avian Hosts.

    PubMed

    Wheeler, Sarah S; Boyce, Walter M; Reisen, William K

    2016-01-01

    Avian hosts play an important role in the spread, maintenance, and amplification of West Nile virus (WNV). Avian susceptibility to WNV varies from species to species thus surveillance efforts can focus both on birds that survive infection and those that succumb. Here we describe methods for the collection and sampling of live birds for WNV antibodies or viremia, and methods for the sampling of dead birds. Target species and study design considerations are discussed.

  14. COMPARISON OF SAMPLING TECHNIQUES USED IN STUDYING LEPIDOPTERA POPULATION DYNAMICS

    EPA Science Inventory

    Four methods (light traps, foliage samples, canvas bands, and gypsy moth egg mass surveys) that are used to study the population dynamics of foliage-feeding Lepidoptera were compared for 10 species, including gypsy moth, Lymantria dispar L. Samples were collected weekly at 12 sit...

  15. Xenosurveillance reflects traditional sampling techniques for the identification of human pathogens: A comparative study in West Africa

    PubMed Central

    Fakoli, Lawrence S.; Bolay, Kpehe; Bolay, Fatorma K.; Diclaro, Joseph W.; Brackney, Doug E.; Stenglein, Mark D.; Ebel, Gregory D.

    2018-01-01

    Background Novel surveillance strategies are needed to detect the rapid and continuous emergence of infectious disease agents. Ideally, new sampling strategies should be simple to implement, technologically uncomplicated, and applicable to areas where emergence events are known to occur. To this end, xenosurveillance is a technique that makes use of blood collected by hematophagous arthropods to monitor and identify vertebrate pathogens. Mosquitoes are largely ubiquitous animals that often exist in sizable populations. As well, many domestic or peridomestic species of mosquitoes will preferentially take blood-meals from humans, making them a unique and largely untapped reservoir to collect human blood. Methodology/Principal findings We sought to take advantage of this phenomenon by systematically collecting blood-fed mosquitoes during a field trail in Northern Liberia to determine whether pathogen sequences from blood engorged mosquitoes accurately mirror those obtained directly from humans. Specifically, blood was collected from humans via finger-stick and by aspirating bloodfed mosquitoes from the inside of houses. Shotgun metagenomic sequencing of RNA and DNA derived from these specimens was performed to detect pathogen sequences. Samples obtained from xenosurveillance and from finger-stick blood collection produced a similar number and quality of reads aligning to two human viruses, GB virus C and hepatitis B virus. Conclusions/Significance This study represents the first systematic comparison between xenosurveillance and more traditional sampling methodologies, while also demonstrating the viability of xenosurveillance as a tool to sample human blood for circulating pathogens. PMID:29561834

  16. Xenosurveillance reflects traditional sampling techniques for the identification of human pathogens: A comparative study in West Africa.

    PubMed

    Fauver, Joseph R; Weger-Lucarelli, James; Fakoli, Lawrence S; Bolay, Kpehe; Bolay, Fatorma K; Diclaro, Joseph W; Brackney, Doug E; Foy, Brian D; Stenglein, Mark D; Ebel, Gregory D

    2018-03-01

    Novel surveillance strategies are needed to detect the rapid and continuous emergence of infectious disease agents. Ideally, new sampling strategies should be simple to implement, technologically uncomplicated, and applicable to areas where emergence events are known to occur. To this end, xenosurveillance is a technique that makes use of blood collected by hematophagous arthropods to monitor and identify vertebrate pathogens. Mosquitoes are largely ubiquitous animals that often exist in sizable populations. As well, many domestic or peridomestic species of mosquitoes will preferentially take blood-meals from humans, making them a unique and largely untapped reservoir to collect human blood. We sought to take advantage of this phenomenon by systematically collecting blood-fed mosquitoes during a field trail in Northern Liberia to determine whether pathogen sequences from blood engorged mosquitoes accurately mirror those obtained directly from humans. Specifically, blood was collected from humans via finger-stick and by aspirating bloodfed mosquitoes from the inside of houses. Shotgun metagenomic sequencing of RNA and DNA derived from these specimens was performed to detect pathogen sequences. Samples obtained from xenosurveillance and from finger-stick blood collection produced a similar number and quality of reads aligning to two human viruses, GB virus C and hepatitis B virus. This study represents the first systematic comparison between xenosurveillance and more traditional sampling methodologies, while also demonstrating the viability of xenosurveillance as a tool to sample human blood for circulating pathogens.

  17. Advances in paper-based sample pretreatment for point-of-care testing.

    PubMed

    Tang, Rui Hua; Yang, Hui; Choi, Jane Ru; Gong, Yan; Feng, Shang Sheng; Pingguan-Murphy, Belinda; Huang, Qing Sheng; Shi, Jun Ling; Mei, Qi Bing; Xu, Feng

    2017-06-01

    In recent years, paper-based point-of-care testing (POCT) has been widely used in medical diagnostics, food safety and environmental monitoring. However, a high-cost, time-consuming and equipment-dependent sample pretreatment technique is generally required for raw sample processing, which are impractical for low-resource and disease-endemic areas. Therefore, there is an escalating demand for a cost-effective, simple and portable pretreatment technique, to be coupled with the commonly used paper-based assay (e.g. lateral flow assay) in POCT. In this review, we focus on the importance of using paper as a platform for sample pretreatment. We firstly discuss the beneficial use of paper for sample pretreatment, including sample collection and storage, separation, extraction, and concentration. We highlight the working principle and fabrication of each sample pretreatment device, the existing challenges and the future perspectives for developing paper-based sample pretreatment technique.

  18. Volatile organic compounds: sampling methods and their worldwide profile in ambient air.

    PubMed

    Kumar, Anuj; Víden, Ivan

    2007-08-01

    The atmosphere is a particularly difficult analytical system because of the very low levels of substances to be analysed, sharp variations in pollutant levels with time and location, differences in wind, temperature and humidity. This makes the selection of an efficient sampling technique for air analysis a key step to reliable results. Generally, methods for volatile organic compounds sampling include collection of the whole air or preconcentration of samples on adsorbents. All the methods vary from each other according to the sampling technique, type of sorbent, method of extraction and identification technique. In this review paper we discuss various important aspects for sampling of volatile organic compounds by the widely used and advanced sampling methods. Characteristics of various adsorbents used for VOCs sampling are also described. Furthermore, this paper makes an effort to comprehensively review the concentration levels of volatile organic compounds along with the methodology used for analysis, in major cities of the world.

  19. Use of X-ray diffraction technique and chemometrics to aid soil sampling strategies in traceability studies.

    PubMed

    Bertacchini, Lucia; Durante, Caterina; Marchetti, Andrea; Sighinolfi, Simona; Silvestri, Michele; Cocchi, Marina

    2012-08-30

    Aim of this work is to assess the potentialities of the X-ray powder diffraction technique as fingerprinting technique, i.e. as a preliminary tool to assess soil samples variability, in terms of geochemical features, in the context of food geographical traceability. A correct approach to sampling procedure is always a critical issue in scientific investigation. In particular, in food geographical traceability studies, where the cause-effect relations between the soil of origin and the final foodstuff is sought, a representative sampling of the territory under investigation is certainly an imperative. This research concerns a pilot study to investigate the field homogeneity with respect to both field extension and sampling depth, taking also into account the seasonal variability. Four Lambrusco production sites of the Modena district were considered. The X-Ray diffraction spectra, collected on the powder of each soil sample, were treated as fingerprint profiles to be deciphered by multivariate and multi-way data analysis, namely PCA and PARAFAC. The differentiation pattern observed in soil samples, as obtained by this fast and non-destructive analytical approach, well matches with the results obtained by characterization with other costly analytical techniques, such as ICP/MS, GFAAS, FAAS, etc. Thus, the proposed approach furnishes a rational basis to reduce the number of soil samples to be collected for further analytical characterization, i.e. metals content, isotopic ratio of radiogenic element, etc., while maintaining an exhaustive description of the investigated production areas. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Synchronous in-field application of life-detection techniques in planetary analog missions

    NASA Astrophysics Data System (ADS)

    Amador, Elena S.; Cable, Morgan L.; Chaudry, Nosheen; Cullen, Thomas; Gentry, Diana; Jacobsen, Malene B.; Murukesan, Gayathri; Schwieterman, Edward W.; Stevens, Adam H.; Stockton, Amanda; Yin, Chang; Cullen, David C.; Geppert, Wolf

    2015-02-01

    Field expeditions that simulate the operations of robotic planetary exploration missions at analog sites on Earth can help establish best practices and are therefore a positive contribution to the planetary exploration community. There are many sites in Iceland that possess heritage as planetary exploration analog locations and whose environmental extremes make them suitable for simulating scientific sampling and robotic operations. We conducted a planetary exploration analog mission at two recent lava fields in Iceland, Fimmvörðuháls (2010) and Eldfell (1973), using a specially developed field laboratory. We tested the utility of in-field site sampling down selection and tiered analysis operational capabilities with three life detection and characterization techniques: fluorescence microscopy (FM), adenine-triphosphate (ATP) bioluminescence assay, and quantitative polymerase chain reaction (qPCR) assay. The study made use of multiple cycles of sample collection at multiple distance scales and field laboratory analysis using the synchronous life-detection techniques to heuristically develop the continuing sampling and analysis strategy during the expedition. Here we report the operational lessons learned and provide brief summaries of scientific data. The full scientific data report will follow separately. We found that rapid in-field analysis to determine subsequent sampling decisions is operationally feasible, and that the chosen life detection and characterization techniques are suitable for a terrestrial life-detection field mission. In-field analysis enables the rapid obtainment of scientific data and thus facilitates the collection of the most scientifically relevant samples within a single field expedition, without the need for sample relocation to external laboratories. The operational lessons learned in this study could be applied to future terrestrial field expeditions employing other analytical techniques and to future robotic planetary exploration missions.

  1. Taking a statistical approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wild, M.; Rouhani, S.

    1995-02-01

    A typical site investigation entails extensive sampling and monitoring. In the past, sampling plans have been designed on purely ad hoc bases, leading to significant expenditures and, in some cases, collection of redundant information. In many instances, sampling costs exceed the true worth of the collected data. The US Environmental Protection Agency (EPA) therefore has advocated the use of geostatistics to provide a logical framework for sampling and analysis of environmental data. Geostatistical methodology uses statistical techniques for the spatial analysis of a variety of earth-related data. The use of geostatistics was developed by the mining industry to estimate oremore » concentrations. The same procedure is effective in quantifying environmental contaminants in soils for risk assessments. Unlike classical statistical techniques, geostatistics offers procedures to incorporate the underlying spatial structure of the investigated field. Sample points spaced close together tend to be more similar than samples spaced further apart. This can guide sampling strategies and determine complex contaminant distributions. Geostatistic techniques can be used to evaluate site conditions on the basis of regular, irregular, random and even spatially biased samples. In most environmental investigations, it is desirable to concentrate sampling in areas of known or suspected contamination. The rigorous mathematical procedures of geostatistics allow for accurate estimates at unsampled locations, potentially reducing sampling requirements. The use of geostatistics serves as a decision-aiding and planning tool and can significantly reduce short-term site assessment costs, long-term sampling and monitoring needs, as well as lead to more accurate and realistic remedial design criteria.« less

  2. Blood venous sample collection: Recommendations overview and a checklist to improve quality.

    PubMed

    Giavarina, Davide; Lippi, Giuseppe

    2017-07-01

    The extra-analytical phases of the total testing process have substantial impact on managed care, as well as an inherent high risk of vulnerability to errors which is often greater than that of the analytical phase. The collection of biological samples is a crucial preanalytical activity. Problems or errors occurring shortly before, or soon after, this preanalytical step may impair sample quality and characteristics, or else modify the final results of testing. The standardization of fasting requirements, rest, patient position and psychological state of the patient are therefore crucial for mitigating the impact of preanalytical variability. Moreover, the quality of materials used for collecting specimens, along with their compatibility, can guarantee sample quality and persistence of chemical and physical characteristics of the analytes over time, so safeguarding the reliability of testing. Appropriate techniques and sampling procedures are effective to prevent problems such as hemolysis, undue clotting in the blood tube, draw of insufficient sample volume and modification of analyte concentration. An accurate identification of both patient and blood samples is a key priority as for other healthcare activities. Good laboratory practice and appropriate training of operators, by specifically targeting collection of biological samples, blood in particular, may greatly improve this issue, thus lowering the risk of errors and their adverse clinical consequences. The implementation of a simple and rapid check-list, including verification of blood collection devices, patient preparation and sampling techniques, was found to be effective for enhancing sample quality and reducing some preanalytical errors associated with these procedures. The use of this tool, along with implementation of objective and standardized systems for detecting non-conformities related to unsuitable samples, can be helpful for standardizing preanalytical activities and improving the quality of laboratory diagnostics, ultimately helping to reaffirm a "preanalytical" culture founded on knowledge and real risk perception. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. Avian Semen Collection by Cloacal Massage and Isolation of DNA from Sperm.

    PubMed

    Kucera, Aurelia C; Heidinger, Britt J

    2018-02-05

    Collection of semen may be useful for a wide range of applications including studies involving sperm quality, sperm telomere dynamics, and epigenetics. Birds are widely used subjects in biological research and are ideal for studies involving repeated sperm samples. However, few resources are currently available for those wishing to learn how to collect and extract DNA from avian sperm. Here we describe cloacal massage, a gentle, non-invasive manual technique for collecting avian sperm. Although this technique is established in the literature, it can be difficult to learn from the available descriptions. We also provide information for extracting DNA from avian semen using a commercial extraction kit with modifications. Cloacal massage can be easily used on any small- to medium-sized male bird in reproductive condition. Following collection, the semen can be used immediately for motility assays, or frozen for DNA extraction following the protocol described herein. This extraction protocol was refined for avian sperm and has been successfully used on samples collected from several passerine species (Passer domesticus, Spizella passerina, Haemorhous mexicanus, and Turdus migratorius) and one columbid (Columba livia).

  4. Heavy metals in atmospheric surrogate dry deposition

    PubMed

    Morselli; Cecchini; Grandi; Iannuccilli; Barilli; Olivieri

    1999-02-01

    This paper describes a methodological approach for the assessment of the amount of surrogate dry deposition of several toxic heavy metals (Cd, Cr, Cu, Ni, Pb, V, Zn) associated with atmospheric particulate matter at ground level. The objectives of the study were twofold: i) the evaluation of several techniques for the digestion of dry deposition samples for trace metal analysis; ii) the comparison of the results from two samplers with different collecting surfaces. A dry solid surface sampler (DRY sampler, Andersen--USA) and a water layer surface sampler (DAS sampler--MTX Italy) were employed. The samples were collected over a one-year period in an urban site of Bologna (northern Italy). A description is given of the complete procedure, from sampling to data elaboration, including sample storage, digestion and analytical methods. According to the results obtained with three different digestion techniques (Teflon bomb, microwave digester and Teflon flask with vapour cooling system), the highest recovery rate was achieved by the Teflon bomb procedure employing an NBS 1648 Standard Reference Material; 90-95% of the elements considered were recovered by dissolution in a pressurized Teflon bomb with an HNO3-HF mixture. Given these results, the technique was adopted for dry deposition sample digestion. On the basis of the amount of heavy metals measured as monthly deposition fluxes (microg/m2), the collecting efficiency of the DAS sampler for a number of elements was found to be as much as two to three times greater than that of the DRY sampler.

  5. Preliminary assessment of an economical fugitive road dust sampler for the collection of bulk samples for geochemical analysis.

    PubMed

    Witt, Emitt C; Wronkiewicz, David J; Shi, Honglan

    2013-01-01

    Fugitive road dust collection for chemical analysis and interpretation has been limited by the quantity and representativeness of samples. Traditional methods of fugitive dust collection generally focus on point-collections that limit data interpretation to a small area or require the investigator to make gross assumptions about the origin of the sample collected. These collection methods often produce a limited quantity of sample that may hinder efforts to characterize the samples by multiple geochemical techniques, preserve a reference archive, and provide a spatially integrated characterization of the road dust health hazard. To achieve a "better sampling" for fugitive road dust studies, a cyclonic fugitive dust (CFD) sampler was constructed and tested. Through repeated and identical sample collection routes at two collection heights (50.8 and 88.9 cm above the road surface), the products of the CFD sampler were characterized using particle size and chemical analysis. The average particle size collected by the cyclone was 17.9 μm, whereas particles collected by a secondary filter were 0.625 μm. No significant difference was observed between the two sample heights tested and duplicates collected at the same height; however, greater sample quantity was achieved at 50.8 cm above the road surface than at 88.9 cm. The cyclone effectively removed 94% of the particles >1 μm, which substantially reduced the loading on the secondary filter used to collect the finer particles; therefore, suction is maintained for longer periods of time, allowing for an average sample collection rate of about 2 g mi. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  6. Method matters: Experimental evidence for shorter avian sperm in faecal compared to abdominal massage samples.

    PubMed

    Girndt, Antje; Cockburn, Glenn; Sánchez-Tójar, Alfredo; Løvlie, Hanne; Schroeder, Julia

    2017-01-01

    Birds are model organisms in sperm biology. Previous work in zebra finches, suggested that sperm sampled from males' faeces and ejaculates do not differ in size. Here, we tested this assumption in a captive population of house sparrows, Passer domesticus. We compared sperm length in samples from three collection techniques: female dummy, faecal and abdominal massage samples. We found that sperm were significantly shorter in faecal than abdominal massage samples, which was explained by shorter heads and midpieces, but not flagella. This result might indicate that faecal sampled sperm could be less mature than sperm collected by abdominal massage. The female dummy method resulted in an insufficient number of experimental ejaculates because most males ignored it. In light of these results, we recommend using abdominal massage as a preferred method for avian sperm sampling. Where avian sperm cannot be collected by abdominal massage alone, we advise controlling for sperm sampling protocol statistically.

  7. A non-invasive technique to bleed incubating birds without trapping: A blood-sucking bug in a hollow egg

    USGS Publications Warehouse

    Becker, P.H.; Voigt, C.C.; Arnold, J.M.; Nagel, R.

    2006-01-01

    We describe a non-invasive technique to obtain blood samples from incubating birds without trapping and handling. A larval instar of the blood-sucking bug Dipetalogaster maximus (Heteroptera) was put in a hollowed artificial egg which was placed in a common tern Sterna hirundo) nest. A gauze-covered hole in the egg allowed the bug to draw blood from the brood patch of breeding adults. We successfully collected 68 blood samples of sufficient amount (median=187 ??l). The daily success rate was highest during the early breeding season and averaged 34% for all trials. We could not detect any visible response by the incubating bird to the sting of the bug. This technique allows for non-invasive blood collection from bird species of various sizes without disturbance. ?? Dt. Ornithologen-Gesellschaft e.V. 2005.

  8. Single-particle characterization of urban aerosol particles collected in three Korean cites using low-Z electron probe X-ray microanalysis.

    PubMed

    Ro, Chul-Un; Kim, HyeKyeong; Oh, Keun-Young; Yea, Sun Kyung; Lee, Chong Bum; Jang, Meongdo; Van Grieken, René

    2002-11-15

    A recently developed single-particle analytical technique, called low-Z electron probe X-ray microanalysis (low-Z EPMA), was applied to characterize urban aerosol particles collected in three cities of Korea (Seoul, CheongJu, and ChunCheon) on single days in the winter of 1999. In this study, it is clearly demonstrated that the low-Z EPMA technique can provide detailed and quantitative information on the chemical composition of particles in the urban atmosphere. The collected aerosol particles were analyzed and classified on the basis of their chemical species. Various types of particles were identified, such as soil-derived, carbonaceous, marine-originated, and anthropogenic particles. In the sample collected in Seoul, carbonaceous, aluminosilicates, silicon dioxide, and calcium carbonate aerosol particles were abundantly encountered. In the CheongJu and ChunCheon samples, carbonaceous, aluminosilicates, reacted sea salts, and ammonium sulfate aerosol particles were often seen. However, in the CheongJu sample, ammonium sulfate particles were the most abundant in the fine fraction. Also, calcium sulfate and nitrate particles were significantly observed. In the ChunCheon sample, organic particles were the most abundant in the fine fraction. Also, sodium nitrate particles were seen at high levels. The ChunCheon sample seemed to be strongly influenced by sea-salt aerosols originating from the Yellow Sea, which is located about 115 km away from the city.

  9. Estimating time-dependent ROC curves using data under prevalent sampling.

    PubMed

    Li, Shanshan

    2017-04-15

    Prevalent sampling is frequently a convenient and economical sampling technique for the collection of time-to-event data and thus is commonly used in studies of the natural history of a disease. However, it is biased by design because it tends to recruit individuals with longer survival times. This paper considers estimation of time-dependent receiver operating characteristic curves when data are collected under prevalent sampling. To correct the sampling bias, we develop both nonparametric and semiparametric estimators using extended risk sets and the inverse probability weighting techniques. The proposed estimators are consistent and converge to Gaussian processes, while substantial bias may arise if standard estimators for right-censored data are used. To illustrate our method, we analyze data from an ovarian cancer study and estimate receiver operating characteristic curves that assess the accuracy of the composite markers in distinguishing subjects who died within 3-5 years from subjects who remained alive. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  10. Assessment of ovarian cycles in the African elephant (Loxodonta africana) by measurement of salivary progesterone metabolites.

    PubMed

    Illera, Juan-Carlos; Silván, Gema; Cáceres, Sara; Carbonell, Maria-Dolores; Gerique, Cati; Martínez-Fernández, Leticia; Munro, Coralie; Casares, Miguel

    2014-01-01

    Monitoring ovarian cycles through hormonal analysis is important in order to improve breeding management of captive elephants, and non-invasive collection techniques are particularly interesting for this purpose. However, there are some practical difficulties in collecting proper samples, and easier and more practical methods may be an advantage for some institutions and/or some animals. This study describes the development and validation of an enzymeimmunoassay (EIA) for progestins in salivary samples of African elephants, Loxodonta africana. Weekly urinary and salivary samples from five non-pregnant elephant cows aged 7-12 years were obtained for 28 weeks and analyzed using EIA. Both techniques correlated positively (r = 0.799; P < 0.001), and the cycle characteristics obtained were identical. The results clearly show that ovarian cycles can be monitored by measuring progestins from salivary samples in the African elephant. This is a simple and non-invasive method that may be a practical alternative to other sampling methods used in the species. © 2014 Wiley Periodicals, Inc.

  11. Penetrator Coring Apparatus for Cometary Surfaces

    NASA Technical Reports Server (NTRS)

    Braun, David F.; Heinrich, Michael; Ai, Huirong Anita; Ahrens, Thomas J.

    2004-01-01

    Touch and go impact coring is an attractive technique for sampling cometary nuclei and asteroidal surface on account of the uncertain strength properties and low surface gravities of these objects. Initial coring experiments in low temperature (approx. 153K polycrystalline ice) and porous rock demonstrate that simultaneous with impact coring, measurements of both the penetration strength and constraints on the frictional properties of surface materials can be obtained upon core penetration and core sample extraction. The method of sampling an asteroid, to be deployed, on the now launched MUSES-C mission, employs a small gun device that fires into the asteroid and the resulted impact ejecta is collected for return to Earth. This technique is well suited for initial sampling in a very low gravity environment and deployment depends little on asteroid surface mechanical properties. Since both asteroids and comets are believed to have altered surface properties a simple sampling apparatus that preserves stratigraphic information, such as impact coring is an attractive alternate to impact ejecta collection.

  12. Fetal Tissue Procurement for Karyotype Analysis: Clinician or Pathologist - Which is Better?

    PubMed

    Conant, Joanna L; Tang, Mary E; Waters, Brenda L

    2016-01-01

    Chromosomal abnormalities are detected in up to 13% of stillbirths and over 20% of those with developmental anomalies. These estimates may be low since up to 50% of samples fail to achieve a result due to microbial overgrowth or nonviability. Tissue for cytogenetics can be procured at bedside by the clinician or by the pathologist in the laboratory. With clinical collection, tissue is placed into culture media immediately, increasing chances of growth. However, collection competes for attention with other activities, which may result in microbial overgrowth or selection of maternal rather than fetal tissue. Laboratory procurement occurs in a controlled environment using sterile technique, but delay in collection may decrease viability. Our goal was to determine which collection method yields better results. We reviewed cases from 2007-2013 that had two samples submitted for cytogenetics, one from the clinician and one from the pathologist. Specimen source, delivery, collection, and culture setup times, harvest date, cell growth, microbial overgrowth, maternal contamination and final result were obtained from medical records and cytogenetic culture sheets. There was no difference in growth rate, maternal cell contamination, or reporting time between clinician- and pathologist-procured samples despite delay in collection time for laboratory samples. Clinical samples had more microbial overgrowth. Compared to samples collected at bedside, samples collected in the laboratory had a lower rate of microbial contamination with similar growth and maternal cell contamination rates, despite prolonged time to collection. Collecting samples both at bedside and in the laboratory is unnecessary.

  13. A mineral reconnaissance sampling manual for Costa Rica: Central American energy and resoure project. Manual para muestreo en el reconocimiento mineral de Costa Rica: Proyecto Centroamericano de energia y recursos naturales (in English and Spanish)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bolivar, S.

    This manual describes field procedures for the collection of stream-sediment and rock samples as part of the Mineral Resource Assessment of Costa Rica. It provides guidelines to be followed by personnel collecting, treating, or otherwise handling samples taken as part of this program. The objectives of the manual are to ensure that all samples are collected uniformly and consistent techniques are employed throughout the program. If this is done, the data from this study can be used to identify areas with potential for mineralization. This manual can also be used as a guideline for future geochemical sampling programs in Costamore » Rica.« less

  14. Clinical application of microsampling versus conventional sampling techniques in the quantitative bioanalysis of antibiotics: a systematic review.

    PubMed

    Guerra Valero, Yarmarly C; Wallis, Steven C; Lipman, Jeffrey; Stove, Christophe; Roberts, Jason A; Parker, Suzanne L

    2018-03-01

    Conventional sampling techniques for clinical pharmacokinetic studies often require the removal of large blood volumes from patients. This can result in a physiological or emotional burden, particularly for neonates or pediatric patients. Antibiotic pharmacokinetic studies are typically performed on healthy adults or general ward patients. These may not account for alterations to a patient's pathophysiology and can lead to suboptimal treatment. Microsampling offers an important opportunity for clinical pharmacokinetic studies in vulnerable patient populations, where smaller sample volumes can be collected. This systematic review provides a description of currently available microsampling techniques and an overview of studies reporting the quantitation and validation of antibiotics using microsampling. A comparison of microsampling to conventional sampling in clinical studies is included.

  15. Comparison of two headspace sampling techniques for the analysis of off-flavour volatiles from oat based products.

    PubMed

    Cognat, Claudine; Shepherd, Tom; Verrall, Susan R; Stewart, Derek

    2012-10-01

    Two different headspace sampling techniques were compared for analysis of aroma volatiles from freshly produced and aged plain oatcakes. Solid phase microextraction (SPME) using a Carboxen-Polydimethylsiloxane (PDMS) fibre and entrainment on Tenax TA within an adsorbent tube were used for collection of volatiles. The effects of variation in the sampling method were also considered using SPME. The data obtained using both techniques were processed by multivariate statistical analysis (PCA). Both techniques showed similar capacities to discriminate between the samples at different ages. Discrimination between fresh and rancid samples could be made on the basis of changes in the relative abundances of 14-15 of the constituents in the volatile profiles. A significant effect on the detection level of volatile compounds was observed when samples were crushed and analysed by SPME-GC-MS, in comparison to undisturbed product. The applicability and cost effectiveness of both methods were considered. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Soil forensics: How far can soil clay analysis distinguish between soil vestiges?

    PubMed

    Corrêa, R S; Melo, V F; Abreu, G G F; Sousa, M H; Chaker, J A; Gomes, J A

    2018-03-01

    Soil traces are useful as forensic evidences because they frequently adhere to individuals and objects associated with crimes and can place or discard a suspect at/from a crime scene. Soil is a mixture of organic and inorganic components and among them soil clay contains signatures that make it reliable as forensic evidence. In this study, we hypothesized that soils can be forensically distinguished through the analysis of their clay fraction alone, and that samples of the same soil type can be consistently distinguished according to the distance they were collected from each other. To test these hypotheses 16 Oxisol samples were collected at distances of between 2m and 1.000m, and 16 Inceptisol samples were collected at distances of between 2m and 300m from each other. Clay fractions were extracted from soil samples and analyzed for hyperspectral color reflectance (HSI), X-ray diffraction crystallographic (XRD), and for contents of iron oxides, kaolinite and gibbsite. The dataset was submitted to multivariate analysis and results were from 65% to 100% effective to distinguish between samples from the two soil types. Both soil types could be consistently distinguished for forensic purposes according to the distance that samples were collected from each other: 1000m for Oxisol and 10m for Inceptisol. Clay color and XRD analysis were the most effective techniques to distinguish clay samples, and Inceptisol samples were more easily distinguished than Oxisol samples. Soil forensics seems a promising field for soil scientists as soil clay can be useful as forensic evidence by using routine analytical techniques from soil science. Copyright © 2017 The Chartered Society of Forensic Sciences. Published by Elsevier B.V. All rights reserved.

  17. Variation in aluminum, iron, and particle concentrations in oxic ground-water samples collected by use of tangential-flow ultrafiltration with low-flow sampling

    USGS Publications Warehouse

    Szabo, Z.; Oden, J.H.; Gibs, J.; Rice, D.E.; Ding, Y.; ,

    2001-01-01

    Particulates that move with ground water and those that are artificially mobilized during well purging could be incorporated into water samples during collection and could cause trace-element concentrations to vary in unfiltered samples, and possibly in filtered samples (typically 0.45-um (micron) pore size) as well, depending on the particle-size fractions present. Therefore, measured concentrations may not be representative of those in the aquifer. Ground water may contain particles of various sizes and shapes that are broadly classified as colloids, which do not settle from water, and particulates, which do. In order to investigate variations in trace-element concentrations in ground-water samples as a function of particle concentrations and particle-size fractions, the U.S. Geological Survey, in cooperation with the U.S. Air Force, collected samples from five wells completed in the unconfined, oxic Kirkwood-Cohansey aquifer system of the New Jersey Coastal Plain. Samples were collected by purging with a portable pump at low flow (0.2-0.5 liters per minute and minimal drawdown, ideally less than 0.5 foot). Unfiltered samples were collected in the following sequence: (1) within the first few minutes of pumping, (2) after initial turbidity declined and about one to two casing volumes of water had been purged, and (3) after turbidity values had stabilized at less than 1 to 5 Nephelometric Turbidity Units. Filtered samples were split concurrently through (1) a 0.45-um pore size capsule filter, (2) a 0.45-um pore size capsule filter and a 0.0029-um pore size tangential-flow filter in sequence, and (3), in selected cases, a 0.45-um and a 0.05-um pore size capsule filter in sequence. Filtered samples were collected concurrently with the unfiltered sample that was collected when turbidity values stabilized. Quality-assurance samples consisted of sequential duplicates (about 25 percent) and equipment blanks. Concentrations of particles were determined by light scattering. Variations in concentrations aluminum and iron (1 -74 and 1-199 ug/L (micrograms per liter), respectively), common indicators of the presence of particulate-borne trace elements, were greatest in sample sets from individual wells with the greatest variations in turbidity and particle concentration. Differences in trace-element concentrations in sequentially collected unfiltered samples with variable turbidity were 5 to 10 times as great as those in concurrently collected samples that were passed through various filters. These results indicate that turbidity must be both reduced and stabilized even when low-flow sample-collection techniques are used in order to obtain water samples that do not contain considerable particulate artifacts. Currently (2001) available techniques need to be refined to ensure that the measured trace-element concentrations are representative of those that are mobile in the aquifer water.

  18. Use of swabs for sampling epithelial cells for molecular genetics analyses in Enteroctopus

    USGS Publications Warehouse

    Hollenback, Nathan; Scheel, David; Gravley, Megan C.; Sage, George K.; Toussaint, Rebecca K.; Talbot, Sandra L.

    2017-01-01

    We evaluated the efficacy of using swabs to collect cells from the epidermis of octopus as a non-invasive DNA source for classical genetic studies, and demonstrated value of the technique by incorporating it into an effort to determine, within a day, the lineage of captured, live Enteroctopus (E. dofleini or a cryptic lineage). The cryptic lineage was targeted for captive behavioral and morphological studies, while once genetically identified, the non-target lineage could be more rapidly released back to the wild. We used commercially available sterile foamtipped swabs and a high-salt preservation buffer to collect and store paired swab and muscle (arm tip) tissue sampled from live Enteroctopus collected from Prince William Sound, Alaska. We performed a one-day extraction of DNA from epithelial swab samples and amplification of two diagnostic microsatellite loci to determine the lineage of each of the 21 individuals. Following this rapid lineage assessment, which allowed us to release non-target individuals within a day of laboratory work, we compared paired swab and muscle tissue samples from each individual to assess quantity of DNA yields and consistency of genotyping results, followed by assessment of locus-by-locus reliability of DNA extracts from swabs. Epithelial swabs yielded, on average, lower quantities of DNA (170.32 ± 74.72 (SD) ng/μL) relative to DNA obtained from tissues collected using invasive or destructive techniques (310.95 ± 147.37 (SD) ng/μL. We observed some decrease in yields of DNA from extractions of swab samples conducted 19 and 31 months after initial extractions when samples were stored at room temperature in lysis buffer. All extractions yielded quantities of DNA sufficient to amplify and score all loci, which included fragment data from 10 microsatellite loci (nine polymorphic loci and monomorphic locus EdoμA106), and nucleotide sequence data from a 528 base pair portion of the nuclear octopine dehydrogenase gene. All results from genotyping and sequencing using paired swab and muscle tissue extracts were concordant, and experimental reliability levels for multilocus genotypes generated from swab samples exceeded 97%. This technique is useful for studies in which invasive sampling is not optimal, and in remote field situations since samples can be stored at ambient temperatures for at least 31 months. The use of epithelial swabs is thus a noninvasive technique appropriate for sampling genetic material from live octopuses for use in classical genetic studies as well as supporting experimental and behavioral studies.

  19. Use of body-mounted cameras to enhance data collection: an evaluation of two arthropod sampling techniques

    USDA-ARS?s Scientific Manuscript database

    A study was conducted that compared the effectiveness of a sweepnet versus a vacuum suction device for collecting arthropods in cotton. The study differs from previous research in that body-mounted action cameras (B-MACs) were used to record the activity of the person conducting the collections. The...

  20. Lead Concentration Levels in Water Samples Collected in Alameda County, CA

    NASA Astrophysics Data System (ADS)

    Sethy, D.; Hoang, R.; Yu, I.; Hernandez, N.; Fang, K.; Zhang, W.; Li, J.; Munui, K. N.; Sot, R.; Luong, K.; Bonzo, R.; Sankar, R.; Chiu, D.; Rodriguez, V. A.

    2016-12-01

    The recent health crisis in Flint, Michigan has attracted an amount of interest in other public utilities' water supplies and infrastructure with regards to concerns over the presence of lead. In an effort to begin assessing the potential for a health crisis similar to that experienced in Flynt, during 2016 our team measured lead concentration levels in water samples by collected in Alameda County. More than 12 sites were selected from which samples were collected. These sites included parks, schools, and private residences. At each site 500mL samples were collected and prepared for later analysis. Samples were subjected to an analytical chemistry technique designed to isolate and concentrate lead to detectable levels of 1 part per billion (ppb). All 8 samples yielded detectable levels of lead; all samples were also well below the EPA regulatory 15 ppb. Two samples collected in West Oakland parks were found to have the highest and lowest levels: DeFremery (4 ppb) and Raimondi (1ppb), respectively. Though preliminary in nature, results from this study suggest that further investigations should be undertaken to assess possible lead contamination associated with drinking water sources in Alameda County.

  1. Comparison of Techniques for Sampling Adult Necrophilous Insects From Pig Carcasses.

    PubMed

    Cruise, Angela; Hatano, Eduardo; Watson, David W; Schal, Coby

    2018-02-06

    Studies of the pre-colonization interval and mechanisms driving necrophilous insect ecological succession depend on effective sampling of adult insects and knowledge of their diel and successional activity patterns. The number of insects trapped, their diversity, and diel periodicity were compared with four sampling methods on neonate pigs. Sampling method, time of day and decomposition age of the pigs significantly affected the number of insects sampled from pigs. We also found significant interactions of sampling method and decomposition day, time of sampling and decomposition day. No single method was superior to the other methods during all three decomposition days. Sampling times after noon yielded the largest samples during the first 2 d of decomposition. On day 3 of decomposition however, all sampling times were equally effective. Therefore, to maximize insect collections from neonate pigs, the method used to sample must vary by decomposition day. The suction trap collected the most species-rich samples, but sticky trap samples were the most diverse, when both species richness and evenness were factored into a Shannon diversity index. Repeated sampling during the noon to 18:00 hours period was most effective to obtain the maximum diversity of trapped insects. The integration of multiple sampling techniques would most effectively sample the necrophilous insect community. However, because all four tested methods were deficient at sampling beetle species, future work should focus on optimizing the most promising methods, alone or in combinations, and incorporate hand-collections of beetles. © The Author(s) 2018. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  2. Non-terminal blood sampling techniques in guinea pigs.

    PubMed

    Birck, Malene M; Tveden-Nyborg, Pernille; Lindblad, Maiken M; Lykkesfeldt, Jens

    2014-10-11

    Guinea pigs possess several biological similarities to humans and are validated experimental animal models(1-3). However, the use of guinea pigs currently represents a relatively narrow area of research and descriptive data on specific methodology is correspondingly scarce. The anatomical features of guinea pigs are slightly different from other rodent models, hence modulation of sampling techniques to accommodate for species-specific differences, e.g., compared to mice and rats, are necessary to obtain sufficient and high quality samples. As both long and short term in vivo studies often require repeated blood sampling the choice of technique should be well considered in order to reduce stress and discomfort in the animals but also to ensure survival as well as compliance with requirements of sample size and accessibility. Venous blood samples can be obtained at a number of sites in guinea pigs e.g., the saphenous and jugular veins, each technique containing both advantages and disadvantages(4,5). Here, we present four different blood sampling techniques for either conscious or anaesthetized guinea pigs. The procedures are all non-terminal procedures provided that sample volumes and number of samples do not exceed guidelines for blood collection in laboratory animals(6). All the described methods have been thoroughly tested and applied for repeated in vivo blood sampling in studies within our research facility.

  3. Distribution and risk factors of Ascarididae and other geohelminths in the soil of Uberlandia, Minas Gerais, Brazil

    PubMed Central

    Mota, Kelem Cristina Pereira; Grama, Daliane Faria; Fava, Natália M. Nasser; Úngari, Letícia Pereira; Faria, Elaine Silva Marques; Cury, Márcia Cristina

    2018-01-01

    ABSTRACT Among the geohelminths, parasites from the Ascarididae family have a significant role in the human and animal health. This research aims to determine the prevalence of Ascarididae species in the soil in different areas located in a city of Minas Gerais State, Brazil (South America). The study was developed in squares, parks, sports clubs, orchards and municipal children's schools. Samples of sand/soil/grass were collected from January to August 2014. The optical microscope screening was performed through formal-ether and spontaneous sedimentation techniques. Out of the 183 collected samples, eight (4.4%) belonged to parks, 16 (8.7%) to sports clubs, 76 (41.5%) to squares, 23 (12.6%) to orchards, and 60 (32.8%) to schools. Out of the total, 28 (15.3%) contained Ascarididae eggs. Higher levels of positivity were demonstrated in the raining season (25.0%), in samples collected in the southern region of the town (25.1%), on ground soils (27.3%). Twenty-three (12.6%) were detected by the formal-ether sedimentation technique and 10 (5.5%) by spontaneous sedimentation technique. Therefore, it was concluded that the soils in the city of Uberlandia are contaminated with eggs and larvae of geohelminths, enabling dissemination of illnesses among animals and human beings. PMID:29694601

  4. Distribution and risk factors of Ascarididae and other geohelminths in the soil of Uberlandia, Minas Gerais, Brazil.

    PubMed

    Mota, Kelem Cristina Pereira; Grama, Daliane Faria; Fava, Natália M Nasser; Úngari, Letícia Pereira; Faria, Elaine Silva Marques; Cury, Márcia Cristina

    2018-01-01

    Among the geohelminths, parasites from the Ascarididae family have a significant role in the human and animal health. This research aims to determine the prevalence of Ascarididae species in the soil in different areas located in a city of Minas Gerais State, Brazil (South America). The study was developed in squares, parks, sports clubs, orchards and municipal children's schools. Samples of sand/soil/grass were collected from January to August 2014. The optical microscope screening was performed through formal-ether and spontaneous sedimentation techniques. Out of the 183 collected samples, eight (4.4%) belonged to parks, 16 (8.7%) to sports clubs, 76 (41.5%) to squares, 23 (12.6%) to orchards, and 60 (32.8%) to schools. Out of the total, 28 (15.3%) contained Ascarididae eggs. Higher levels of positivity were demonstrated in the raining season (25.0%), in samples collected in the southern region of the town (25.1%), on ground soils (27.3%). Twenty-three (12.6%) were detected by the formal-ether sedimentation technique and 10 (5.5%) by spontaneous sedimentation technique. Therefore, it was concluded that the soils in the city of Uberlandia are contaminated with eggs and larvae of geohelminths, enabling dissemination of illnesses among animals and human beings.

  5. Faster the better: a reliable technique to sample anopluran lice in large hosts.

    PubMed

    Leonardi, María Soledad

    2014-06-01

    Among Anoplura, the family Echinophthiriidae includes those species that infest mainly the pinnipeds. Working with large hosts implies methodological considerations as the time spent in the sampling, and the way in that the animal is restrained. Previous works on echinophthiriids combined a diverse array of analyses including field counts of lice and in vitro observations. To collect lice, the authors used forceps, and each louse was collected individually. This implied a long manipulation time, i.e., ≈60 min and the need to physically and/or chemically immobilize the animal. The present work described and discussed for the first a sample technique that minimized the manipulation time and also avoiding the use of anesthesia. This methodology implied combing the host's pelage with a fine-tooth plastic comb, as used in the treatment of human pediculosis, and keeping the comb with the lice retained in a Ziploc® bag with ethanol. This technique was used successfully in studies of population dynamic, habitat selection, and transmission pattern, being a reliable methodology. Lice are collected entirely and are in a good condition to prepare them for mounting for studying under light or scanning electron microscopy. Moreover, the use of the plastic comb protects from damaging taxonomically important structures as spines being also recommended to reach taxonomic or morphological goals.

  6. On-chip collection of particles and cells by AC electroosmotic pumping and dielectrophoresis using asymmetric microelectrodes

    PubMed Central

    Melvin, Elizabeth M.; Moore, Brandon R.; Gilchrist, Kristin H.; Grego, Sonia; Velev, Orlin D.

    2011-01-01

    The recent development of microfluidic “lab on a chip” devices requiring sample sizes <100 μL has given rise to the need to concentrate dilute samples and trap analytes, especially for surface-based detection techniques. We demonstrate a particle collection device capable of concentrating micron-sized particles in a predetermined area by combining AC electroosmosis (ACEO) and dielectrophoresis (DEP). The planar asymmetric electrode pattern uses ACEO pumping to induce equal, quadrilateral flow directed towards a stagnant region in the center of the device. A number of system parameters affecting particle collection efficiency were investigated including electrode and gap width, chamber height, applied potential and frequency, and number of repeating electrode pairs and electrode geometry. The robustness of the on-chip collection design was evaluated against varying electrolyte concentrations, particle types, and particle sizes. These devices are amenable to integration with a variety of detection techniques such as optical evanescent waveguide sensing. PMID:22662040

  7. Fallon, Nevada FORGE Fluid Geochemistry

    DOE Data Explorer

    Blankenship, Doug; Ayling, Bridget

    2018-03-13

    Fluid geochemistry analysis for wells supporting the Fallon FORGE project. Samples were collected from geothermal wells using standard geothermal water sampling techniques, including filtration and acidification of the cation sample to pH < 2 prior to geochemical analysis. Analyses after 2005 were done in reputable commercial laboratories that follow standard protocols for aqueous chemistry analysis.

  8. Salmon redd identification using environmental DNA (eDNA)

    USGS Publications Warehouse

    Pilliod, David S.; Laramie, Matthew B.

    2016-06-10

    IntroductionThe purpose of this project was to develop a technique to use environmental DNA (eDNA) to distinguish between redds made by Chinook salmon (Oncorhynchus tshawytscha) and redds made by Coho salmon (O. kisutch) and to distinguish utilized redds from test/abandoned redds or scours that have the appearance of redds. The project had two phases:Phase 1. Develop, test, and optimize a molecular assay for detecting and identifying Coho salmon DNA and differentiating it from Chinook salmon DNA.Phase 2. Demonstrate the efficacy of the technique.Collect and preserve water samples from the interstitial spaces of 10 known redds (as identified by expert observers) of each species and 10 gravel patches that do not include a redd of either species.Collect control samples from the water column adjacent to each redd to establish background eDNA levels.Analyze the samples using the developed molecular assays for Coho salmon (phase I) and Chinook salmon (Laramie and others, 2015).Evaluate whether samples collected from Chinook and Coho redds have significantly higher levels of eDNA of the respective species than background levels (that is, from gravel, water column).Evaluate whether samples collected from the interstitial spaces of gravel patches that are not redds are similar to background eDNA levels.The Sandy River is a large tributary of the Columbia River. The Sandy River meets the Columbia River approximately 23 km upstream of Portland, Oregon. The Sandy River Basin provides overlapping spawning habitat for both Chinook and Coho salmon.Samples provided by Portland Water Bureau for analysis were collected from the Bull Run River, Sixes Creek, Still Creek, Arrah Wanna Side Channel, and Side Channel 18.

  9. Comparative evaluation of four mosquitoes sampling methods in rice irrigation schemes of lower Moshi, northern Tanzania.

    PubMed

    Kweka, Eliningaya J; Mahande, Aneth M

    2009-07-06

    Adult malaria vector sampling is the most important parameter for setting up an intervention and understanding disease dynamics in malaria endemic areas. The intervention will ideally be species-specific according to sampling output. It was the objective of this study to evaluate four sampling techniques, namely human landing catch, pit shelter, indoor resting collection and odour-baited entry trap. These four sampling methods were evaluated simultaneously for thirty days during October 2008, a season of low mosquitoes density and malaria transmission. These trapping methods were performed in one village for maximizing homogeneity in mosquito density. The cattle and man used in odour-baited entry trap were rotated between the chambers to avoid bias. A total of 3,074 mosquitoes were collected. Among these 1,780 (57.9%) were Anopheles arabiensis and 1,294 (42.1%) were Culex quinquefasciatus. Each trap sampled different number of mosquitoes, Indoor resting collection collected 335 (10.9%), Odour-baited entry trap-cow 1,404 (45.7%), Odour-baited entry trap-human 378 (12.3%), Pit shelter 562 (18.3%) and HLC 395 (12.8%). General linear model univariate analysis method was used, position of the trapping method had no effect on mosquito density catch (DF = 4, F = 35.596, P = 0.78). Days variation had no effect on the collected density too (DF = 29, F = 4.789, P = 0.09). The sampling techniques had significant impact on the caught mosquito densities (DF = 4, F = 34.636, P < 0.0001). The Wilcoxon pair-wise comparison between mosquitoes collected in human landing catch and pit shelter was significant (Z = -3.849, P < 0.0001), human landing catch versus Indoor resting collection was not significant (Z = -0.502, P = 0.615), human landing catch versus odour-baited entry trap-man was significant (Z = -2.687, P = 0.007), human landing catch versus odour-baited entry trap-cow was significant (Z = -3.127, P = 0.002). Odour-baited traps with different baits and pit shelter have shown high productivity in collecting higher densities of mosquitoes than human landing catch. These abilities are the possibilities of replacing the human landing catch practices for sampling malaria vectors in areas with An. arabiensis as malaria vectors. Further evaluations of these sampling methods need to be investigated is other areas with different species.

  10. Combining Laser Ablation/Liquid Phase Collection Surface Sampling and High-Performance Liquid Chromatography Electrospray Ionization Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ovchinnikova, Olga S; Kertesz, Vilmos; Van Berkel, Gary J

    This paper describes the coupling of ambient pressure transmission geometry laser ablation with a liquid phase sample collection method for surface sampling and ionization with subsequent mass spectral analysis. A commercially available autosampler was adapted to produce a liquid droplet at the end of the syringe injection needle while in close proximity to the surface to collect the sample plume produced by laser ablation. The sample collection was followed by either flow injection or a high performance liquid chromatography (HPLC) separation of the extracted components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the analytical utility of thismore » coupling, thin films of a commercial ink sample containing rhodamine 6G and of mixed isobaric rhodamine B and 6G dyes on glass microscope slides were analyzed. The flow injection and HPLC/ESI-MS analysis revealed successful laser ablation, capture and, with HPLC, the separation of the two compounds. The ablated circular area was about 70 m in diameter for these experiments. The spatial sampling resolution afforded by the laser ablation, as well as the ability to use sample processing methods like HPLC between the sample collection and ionization steps, makes this combined surface sampling/ionization technique a highly versatile analytical tool.« less

  11. [Prokaryotic community of subglacial bottom sediments of Antarctic Lake Untersee: detection by cultural and direct microscopic techniques].

    PubMed

    Muliukin, A L; Demkina, E V; Manucharova, N A; Akimov, V N; Andersen, D; McKay, C; Gal'chenko, V F

    2014-01-01

    The heterotrophic mesophilic component was studied in microbial communities of the samples of frozen regolith collected from the glacier near Lake Untersee collected in 2011 during the joint Russian-American expedition to central Dronning Maud Land (Eastern Antarctica). Cultural techniques revealed high bacterial numbers in the samples. For enumeration of viable cells, the most probable numbers (MPN) method proved more efficient than plating on agar media. Fluorescent in situ hybridization with the relevant oligonucleotide probes revealed members of the groups Eubacteria (Actinobacteria, Firmicutes) and Archaea. Application of the methods of cell resuscitation, such as the use of diluted media and prevention of oxidative stress, did not result in a significant increase in the numbers of viable cells retrieved form subglacial sediment samples. Our previous investigations demonstrated the necessity for special procedures for efficient reactivation of the cells from microbial communities of preserved fossil soil and permafrost samples collected in the Arctic zone. The differences in response to the special resuscitation procedures may reflect the differences in the physiological and morphological state of bacterial cells in microbial communities subject to continuous or periodic low temperatures and dehydration.

  12. Molecular comparison of the sampling efficiency of four types of airborne bacterial samplers.

    PubMed

    Li, Kejun

    2011-11-15

    In the present study, indoor and outdoor air samples were collected using four types of air samplers often used for airborne bacterial sampling. These air samplers included two solid impactors (BioStage and RCS), one liquid impinger (BioSampler), and one filter sampler with two kinds of filters (a gelatin and a cellulose acetate filter). The collected air samples were further processed to analyze the diversity and abundance of culturable bacteria and total bacteria through standard culture techniques, denaturing gradient gel electrophoresis (DGGE) fingerprinting and quantitative polymerase chain reaction (qPCR) analysis. The DGGE analysis indicated that the air samples collected using the BioStage and RCS samplers have higher culturable bacterial diversity, whereas the samples collected using the BioSampler and the cellulose acetate filter sampler have higher total bacterial diversity. To obtain more information on the sampled bacteria, some gel bands were excised and sequenced. In terms of sampling efficiency, results from the qPCR tests indicated that the collected total bacterial concentration was higher in samples collected using the BioSampler and the cellulose acetate filter sampler. In conclusion, the sampling bias and efficiency of four kinds of air sampling systems were compared in the present study and the two solid impactors were concluded to be comparatively efficient for culturable bacterial sampling, whereas the liquid impactor and the cellulose acetate filter sampler were efficient for total bacterial sampling. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Precise Manipulation and Patterning of Protein Crystals for Macromolecular Crystallography Using Surface Acoustic Waves.

    PubMed

    Guo, Feng; Zhou, Weijie; Li, Peng; Mao, Zhangming; Yennawar, Neela H; French, Jarrod B; Huang, Tony Jun

    2015-06-01

    Advances in modern X-ray sources and detector technology have made it possible for crystallographers to collect usable data on crystals of only a few micrometers or less in size. Despite these developments, sample handling techniques have significantly lagged behind and often prevent the full realization of current beamline capabilities. In order to address this shortcoming, a surface acoustic wave-based method for manipulating and patterning crystals is developed. This method, which does not damage the fragile protein crystals, can precisely manipulate and pattern micrometer and submicrometer-sized crystals for data collection and screening. The technique is robust, inexpensive, and easy to implement. This method not only promises to significantly increase efficiency and throughput of both conventional and serial crystallography experiments, but will also make it possible to collect data on samples that were previously intractable. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Nearest greedy for solving the waste collection vehicle routing problem: A case study

    NASA Astrophysics Data System (ADS)

    Mat, Nur Azriati; Benjamin, Aida Mauziah; Abdul-Rahman, Syariza; Wibowo, Antoni

    2017-11-01

    This paper presents a real case study pertaining to an issue related to waste collection in the northern part of Malaysia by using a constructive heuristic algorithm known as the Nearest Greedy (NG) technique. This technique has been widely used to devise initial solutions for issues concerning vehicle routing. Basically, the waste collection cycle involves the following steps: i) each vehicle starts from a depot, ii) visits a number of customers to collect waste, iii) unloads waste at the disposal site, and lastly, iv) returns to the depot. Moreover, the sample data set used in this paper consisted of six areas, where each area involved up to 103 customers. In this paper, the NG technique was employed to construct an initial route for each area. The solution proposed from the technique was compared with the present vehicle routes implemented by a waste collection company within the city. The comparison results portrayed that NG offered better vehicle routes with a 11.07% reduction of the total distance traveled, in comparison to the present vehicle routes.

  15. Chemical fingerprinting of Arabidopsis using Fourier transform infrared (FT-IR) spectroscopic approaches.

    PubMed

    Gorzsás, András; Sundberg, Björn

    2014-01-01

    Fourier transform infrared (FT-IR) spectroscopy is a fast, sensitive, inexpensive, and nondestructive technique for chemical profiling of plant materials. In this chapter we discuss the instrumental setup, the basic principles of analysis, and the possibilities for and limitations of obtaining qualitative and semiquantitative information by FT-IR spectroscopy. We provide detailed protocols for four fully customizable techniques: (1) Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS): a sensitive and high-throughput technique for powders; (2) attenuated total reflectance (ATR) spectroscopy: a technique that requires no sample preparation and can be used for solid samples as well as for cell cultures; (3) microspectroscopy using a single element (SE) detector: a technique used for analyzing sections at low spatial resolution; and (4) microspectroscopy using a focal plane array (FPA) detector: a technique for rapid chemical profiling of plant sections at cellular resolution. Sample preparation, measurement, and data analysis steps are listed for each of the techniques to help the user collect the best quality spectra and prepare them for subsequent multivariate analysis.

  16. Sample collection and preparation of biofluids and extracts for gas chromatography-mass spectrometry.

    PubMed

    Emwas, Abdul-Hamid M; Al-Talla, Zeyad A; Kharbatia, Najeh M

    2015-01-01

    To maximize the utility of gas chromatography-mass spectrometry (GC-MS) in metabonomics research, all stages of the experimental design should be standardized, including sample collection, storage, preparation, and sample separation. Moreover, the prerequisite for any GC-MS analysis is that a compound must be volatile and thermally stable if it is to be analyzed using this technique. Since many metabolites are nonvolatile and polar in nature, they are not readily amenable to analysis by GC-MS and require initial chemical derivatization of the polar functional groups in order to reduce the polarity and to increase the thermal stability and volatility of the analytes. In this chapter, an overview is presented of the optimum approach to sample collection, storage, and preparation for gas chromatography-mass spectrometry-based metabonomics with particular focus on urine samples as example of biofluids.

  17. System for sampling and monitoring microscopic organisms and substances

    DOEpatents

    Au, Frederick H. F.; Beckert, Werner F.

    1976-01-01

    A technique and apparatus used therewith for determining the uptake of plutonium and other contaminants by soil microorganisms which, in turn, gives a measure of the plutonium and/or other contaminants available to the biosphere at that particular time. A measured quantity of uncontaminated spores of a selected mold is added to a moistened sample of the soil to be tested. The mixture is allowed to sit a predetermined number of days under specified temperature conditions. An agar layer is then applied to the top of the sample. After three or more days, when spores of the mold growing in the sample have formed, the spores are collected by a miniature vacuum collection apparatus operated under preselected vacuum conditions, which collect only the spores with essentially no contamination by mycelial fragments or culture medium. After collection, the fungal spores are dried and analyzed for the plutonium and/or other contaminants. The apparatus is also suitable for collection of pollen, small insects, dust and other small particles, material from thin-layer chromatography plates, etc.

  18. Single-particle mineralogy of Chinese soil particles by the combined use of low-Z particle electron probe X-ray microanalysis and attenuated total reflectance-FT-IR imaging techniques.

    PubMed

    Malek, Md Abdul; Kim, Bowha; Jung, Hae-Jin; Song, Young-Chul; Ro, Chul-Un

    2011-10-15

    Our previous work on the speciation of individual mineral particles of micrometer size by the combined use of attenuated total reflectance FT-IR (ATR-FT-IR) imaging and a quantitative energy-dispersive electron probe X-ray microanalysis technique (EPMA), low-Z particle EPMA, demonstrated that the combined use of these two techniques is a powerful approach for looking at the single-particle mineralogy of externally heterogeneous minerals. In this work, this analytical methodology was applied to characterize six soil samples collected at arid areas in China, in order to identify mineral types present in the samples. The six soil samples were collected from two types of soil, i.e., loess and desert soils, for which overall 665 particles were analyzed on a single particle basis. The six soil samples have different mineralogical characteristics, which were clearly differentiated in this work. As this analytical methodology provides complementary information, the ATR-FT-IR imaging on mineral types, and low-Z particle EPMA on the morphology and elemental concentrations, on the same individual particles, more detailed information can be obtained using this approach than when either low-Z particle EPMA or ATR-FT-IR imaging techniques are used alone, which has a great potential for the characterization of Asian dust and mineral dust particles. © 2011 American Chemical Society

  19. Utilizing Pyrosequencing and Quantitative pCR to Characterize Fungal Populations among House Dust Samples

    EPA Science Inventory

    Molecular techniques are an alternative to culturing and counting methods in quantifying indoor fungal contamination. Pyrosequencing offers the possibility of identifying unexpected indoor fungi. In this study, 50 house dust samples were collected from homes in the Yakima Valley,...

  20. Marine Curators Gather

    ERIC Educational Resources Information Center

    McCoy, Floyd W.

    1977-01-01

    Reports on a recent meeting of marine curators in which data dissemination, standardization of marine curating techniques and methods, responsibilities of curators, funding problems, and sampling equipment were the main areas of discussion. A listing of the major deep sea sample collections in the United States is also provided. (CP)

  1. Wilson Corners SWMU 001 2014 Annual Long Term Monitoring Report Kennedy Space Center, Florida

    NASA Technical Reports Server (NTRS)

    Langenbach, James

    2015-01-01

    This document presents the findings of the 2014 Long Term Monitoring (LTM) that was completed at the Wilson Corners site, located at the National Aeronautics and Space Administration (NASA) John F. Kennedy Space Center (KSC), Florida. The goals of the 2014 annual LTM event were to evaluate the groundwater flow direction and gradient and to monitor the vertical and downgradient horizontal extent of the volatile organic compounds (VOCs) in groundwater at the site. The LTM activities consisted of an annual groundwater sampling event in December 2014, which included the collection of water levels from the LTM wells. During the annual groundwater sampling event, depth to groundwater was measured and VOC samples were collected using passive diffusion bags (PDBs) from 30 monitoring wells. In addition to the LTM sampling, additional assessment sampling was performed at the site using low-flow techniques based on previous LTM results and assessment activities. Assessment of monitoring well MW0052DD was performed by collecting VOC samples using low-flow techniques before and after purging 100 gallons from the well. Monitoring well MW0064 was sampled to supplement shallow VOC data north of Hot Spot 2 and east of Hot Spot 4. Monitoring well MW0089 was sampled due to its proximity to MW0090. MW0090 is screened in a deeper interval and had an unexpected detection of trichloroethene (TCE) during the 2013 LTM, which was corroborated during the March 2014 verification sampling. Monitoring well MW0130 was sampled to provide additional VOC data beneath the semi-confining clay layer in the Hot Spot 2 area.

  2. Comparison of extraction techniques of robenidine from poultry feed samples.

    PubMed

    Wilga, Joanna; Wasik, Agata Kot-; Namieśnik, Jacek

    2007-10-31

    In this paper, effectiveness of six different commonly applied extraction techniques for the determination of robenidine in poultry feed has been compared. The sample preparation techniques included shaking, Soxhlet, Soxtec, ultrasonically assisted extraction, microwave - assisted extraction and accelerated solvent extraction. Comparison of these techniques was done with respect to the recovery extraction, temperature and time, reproducibility and solvent consumption. Every single extract was subjected to clean - up using aluminium oxide column (Pasteur pipette filled with 1g of aluminium oxide), from which robenidine was eluted with 10ml of methanol. The eluate from the clean-up column was collected in a volumetric flask, and finally it was analysed by HPLC-DAD-MS. In general, all extraction techniques were capable of isolating of robenidine from poultry feed, but the recovery obtained using modern extraction techniques was higher than that obtained using conventional techniques. In particular, accelerated solvent extraction was more superior to other techniques, which highlights the advantages of this sample preparation technique. However, in routine analysis, shaking and ultrasonically assisted extraction is still the preferred method for the solution of robenidine and other coccidiostatics.

  3. Four Interstellar Dust Candidates from the Stardust Interstellar Dust Collector

    NASA Technical Reports Server (NTRS)

    Westphal, A. J.; Allen, C.; Bajt, S.; Bechtel, H. A.; Borg, J.; Brenker, F.; Bridges, J.; Brownlee, D. E.; Burchell, M.; Burghammer, M.; hide

    2011-01-01

    In January 2006, the Stardust sample return capsule returned to Earth bearing the first solid samples from a primitive solar system body, Comet 81P/Wild2, and a collector dedicated to the capture and return of contemporary interstellar dust. Both collectors were approx. 0.1 sq m in area and were composed of aerogel tiles (85% of the collecting area) and aluminum foils. The Stardust Interstellar Dust Collector (SIDC) was exposed to the interstellar dust stream for a total exposure factor of 20 sq m/day. The Stardust Interstellar Preliminary Examination (ISPE) is a consortium-based project to characterize the collection using nondestructive techniques. The goals and restrictions of the ISPE are described . A summary of analytical techniques is described.

  4. Environmental Monitoring and the Gas Industry: Program Manager Handbook

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gregory D. Gillispie

    1997-12-01

    This document has been developed for the nontechnical gas industry manager who has the responsibility for the development of waste or potentially contaminated soil and groundwater data or must make decisions based on such data for the management or remediation of these materials. It explores the pse of common analytical chemistry instrumentation and associated techniques for identification of environmentally hazardous materials. Sufficient detail is given to familiarize the nontechnical reader with the principles behind the operation of each technique. The scope and realm of the techniques and their constituent variations are portrayed through a discussion of crucial details and, wheremore » appropriate, the depiction of real-life data. It is the author's intention to provide an easily understood handbook for gas industry management. Techniques which determine the presence, composition, and quantification of gas industry wastes are discussed. Greater focus is given to traditional techniques which have been the mainstay of modem analytical benchwork. However, with the continual advancement of instrumental principles and design, several techniques have been included which are likely to receive greater attention in fiture considerations for waste-related detection. Definitions and concepts inherent to a thorough understanding of the principles common to analytical chemistry are discussed. It is also crucial that gas industry managers understand the effects of the various actions which take place before, during, and after the actual sampling step. When a series of sample collection, storage, and transport activities occur, new or inexperienced project managers may overlook or misunderstand the importance of the sequence. Each step has an impact on the final results of the measurement process; errors in judgment or decision making can be costly. Specific techniques and methodologies for the collection, storage, and transport of environmental media samples are not described or discussed in detail in thk handbook. However, the underlying philosophy regarding the importance of proper collection, storage, and transport practices, as well as pertinent references, are presented.« less

  5. Lutz's spontaneous sedimentation technique and the paleoparasitological analysis of sambaqui (shell mound) sediments

    PubMed Central

    Camacho, Morgana; Pessanha, Thaíla; Leles, Daniela; Dutra, Juliana MF; Silva, Rosângela; de Souza, Sheila Mendonça; Araujo, Adauto

    2013-01-01

    Parasite findings in sambaquis (shell mounds) are scarce. Although the 121 shell mound samples were previously analysed in our laboratory, we only recently obtained the first positive results. In the sambaqui of Guapi, Rio de Janeiro, Brazil, paleoparasitological analysis was performed on sediment samples collected from various archaeological layers, including the superficial layer as a control. Eggs of Acanthocephala, Ascaridoidea and Heterakoidea were found in the archaeological layers. We applied various techniques and concluded that Lutz's spontaneous sedimentation technique is effective for concentrating parasite eggs in sambaqui soil for microscopic analysis. PMID:23579793

  6. Lutz's spontaneous sedimentation technique and the paleoparasitological analysis of sambaqui (shell mound) sediments.

    PubMed

    Camacho, Morgana; Pessanha, Thaíla; Leles, Daniela; Dutra, Juliana M F; Silva, Rosângela; Souza, Sheila Mendonça de; Araujo, Adauto

    2013-04-01

    Parasite findings in sambaquis (shell mounds) are scarce. Although the 121 shell mound samples were previously analysed in our laboratory, we only recently obtained the first positive results. In the sambaqui of Guapi, Rio de Janeiro, Brazil, paleoparasitological analysis was performed on sediment samples collected from various archaeological layers, including the superficial layer as a control. Eggs of Acanthocephala, Ascaridoidea and Heterakoidea were found in the archaeological layers. We applied various techniques and concluded that Lutz's spontaneous sedimentation technique is effective for concentrating parasite eggs in sambaqui soil for microscopic analysis.

  7. A comparison of honey bee-collected pollen from working agricultural lands using light microscopy and ITS metabarcoding

    USGS Publications Warehouse

    Smart, Matthew; Cornman, Robert S.; Iwanowicz, Deborah; McDermott-Kubeczko, Margaret; Pettis, Jeff S; Spivak, Marla S; Otto, Clint R.

    2017-01-01

    Taxonomic identification of pollen has historically been accomplished via light microscopy but requires specialized knowledge and reference collections, particularly when identification to lower taxonomic levels is necessary. Recently, next-generation sequencing technology has been used as a cost-effective alternative for identifying bee-collected pollen; however, this novel approach has not been tested on a spatially or temporally robust number of pollen samples. Here, we compare pollen identification results derived from light microscopy and DNA sequencing techniques with samples collected from honey bee colonies embedded within a gradient of intensive agricultural landscapes in the Northern Great Plains throughout the 2010–2011 growing seasons. We demonstrate that at all taxonomic levels, DNA sequencing was able to discern a greater number of taxa, and was particularly useful for the identification of infrequently detected species. Importantly, substantial phenological overlap did occur for commonly detected taxa using either technique, suggesting that DNA sequencing is an appropriate, and enhancing, substitutive technique for accurately capturing the breadth of bee-collected species of pollen present across agricultural landscapes. We also show that honey bees located in high and low intensity agricultural settings forage on dissimilar plants, though with overlap of the most abundantly collected pollen taxa. We highlight practical applications of utilizing sequencing technology, including addressing ecological issues surrounding land use, climate change, importance of taxa relative to abundance, and evaluating the impact of conservation program habitat enhancement efforts.

  8. Optimization of the tungsten oxide technique for measurement of atmospheric ammonia

    NASA Technical Reports Server (NTRS)

    Brown, Kenneth G.

    1987-01-01

    Hollow tubes coated with tungstic acid have been shown to be of value in the determination of ammonia and nitric acid in ambient air. Practical application of this technique was demonstrated utilizing an automated sampling system for in-flight collection and analysis of atmospheric samples. Due to time constraints these previous measurements were performed on tubes that had not been well characterized in the laboratory. As a result the experimental precision could not be accurately estimated. Since the technique was being compared to other techniques for measuring these compounds, it became necessary to perform laboratory tests which would establish the reliability of the technique. This report is a summary of these laboratory experiments as they are applied to the determination of ambient ammonia concentration.

  9. Method matters: Experimental evidence for shorter avian sperm in faecal compared to abdominal massage samples

    PubMed Central

    Cockburn, Glenn; Sánchez-Tójar, Alfredo; Løvlie, Hanne; Schroeder, Julia

    2017-01-01

    Birds are model organisms in sperm biology. Previous work in zebra finches, suggested that sperm sampled from males' faeces and ejaculates do not differ in size. Here, we tested this assumption in a captive population of house sparrows, Passer domesticus. We compared sperm length in samples from three collection techniques: female dummy, faecal and abdominal massage samples. We found that sperm were significantly shorter in faecal than abdominal massage samples, which was explained by shorter heads and midpieces, but not flagella. This result might indicate that faecal sampled sperm could be less mature than sperm collected by abdominal massage. The female dummy method resulted in an insufficient number of experimental ejaculates because most males ignored it. In light of these results, we recommend using abdominal massage as a preferred method for avian sperm sampling. Where avian sperm cannot be collected by abdominal massage alone, we advise controlling for sperm sampling protocol statistically. PMID:28813481

  10. EVALUATION OF THE HIGH VOLUME COLLECTION SYSTEM (HVCS) FOR QUANTIFYING FUGITIVE ORGANIC VAPOR LEAKS

    EPA Science Inventory

    The report discusses a recently developed measurements technique that offers the potential for providing an easy-to-use and cost effective means to directly measure organic vapor leaks. The method, called High Volume Collection System (HVCS), uses a high volume sampling device an...

  11. 77 FR 42314 - Proposed Data Collections Submitted for Public Comment and Recommendations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-18

    ... Act of 1970) has the responsibility to conduct research relating to innovative methods, techniques, and approaches dealing with occupational safety and health problems. This research relates to... recruited to diversify the research sample. Data will be collected one time at each mine; this is not a...

  12. Comparison of PIXE and XRF analysis of airborne particulate matter samples collected on Teflon and quartz fibre filters

    NASA Astrophysics Data System (ADS)

    Chiari, M.; Yubero, E.; Calzolai, G.; Lucarelli, F.; Crespo, J.; Galindo, N.; Nicolás, J. F.; Giannoni, M.; Nava, S.

    2018-02-01

    Within the framework of research projects focusing on the sampling and analysis of airborne particulate matter, Particle Induced X-ray Emission (PIXE) and Energy Dispersive X-ray Fluorescence (ED-XRF) techniques are routinely used in many laboratories throughout the world to determine the elemental concentration of the particulate matter samples. In this work an inter-laboratory comparison of the results obtained from analysing several samples (collected on both Teflon and quartz fibre filters) using both techniques is presented. The samples were analysed by PIXE (in Florence, at the 3 MV Tandetron accelerator of INFN-LABEC laboratory) and by XRF (in Elche, using the ARL Quant'X EDXRF spectrometer with specific conditions optimized for specific groups of elements). The results from the two sets of measurements are in good agreement for all the analysed samples, thus validating the use of the ARL Quant'X EDXRF spectrometer and the selected measurement protocol for the analysis of aerosol samples. Moreover, thanks to the comparison of PIXE and XRF results on Teflon and quartz fibre filters, possible self-absorption effects due to the penetration of the aerosol particles inside the quartz fibre-filters were quantified.

  13. Utility of capillary microsampling for rat pharmacokinetic studies: Comparison of tail-vein bleed to jugular vein cannula sampling.

    PubMed

    Korfmacher, Walter; Luo, Yongyi; Ho, Stacy; Sun, Wei; Shen, Liduo; Wang, Jie; Wu, Zhongtao; Guo, Yang; Snow, Gregory; O'Shea, Thomas

    2015-01-01

    Serial sampling methods have been used for rat pharmacokinetic (PK) studies for over 20 years. Currently, it is still common to take 200-250 μL of blood at each timepoint when performing a PK study in rats and using serial sampling. While several techniques have been employed for collecting blood samples from rats, there is only limited published data to compare these methods. Recently, microsampling (≤ 50 μL) techniques have been reported as an alternative process for collecting blood samples from rats. In this report, five compounds were dosed orally into rats. For three proprietary compounds, jugular vein cannula (JVC) sampling was used to collect whole blood and plasma samples and capillary microsampling (CMS) was used to collect blood samples from the tail vein of the same animal. For the two other compounds, marketed drugs fluoxetine and glipizide, JVC sampling was used to collect both whole blood and blood CMS samples while tail-vein sampling from the same rats was also used to collect both whole blood and blood CMS samples. For the three proprietary compounds, the blood AUC as well as the blood concentration-time profile that were obtained from the tail vein were different from those obtained via JVC sampling. For fluoxetine, the blood total exposure (AUC) was not statistically different when comparing tail-vein sampling to JVC sampling, however the blood concentration-time profile that was obtained from the tail vein was different than the one obtained from JVC sampling. For glipizide, the blood AUC and concentration-time profile were not statistically different when comparing the tail-vein sampling to the JVC sampling. For both fluoxetine and glipizide, the blood concentration profiles obtained from CMS were equivalent to the blood concentration profiles obtained from the standard whole blood sampling, collected at the same sampling site. The data in this report provide strong evidence that blood CMS is a valuable small volume blood sampling approach for rats and that it provides results for test compound concentrations that are equivalent to those obtained from traditional whole blood sampling. The data also suggest that for some compounds, the concentration-time profile that is obtained for a test compound based on sampling from a rat tail vein may be different from that obtained from rat JVC sampling. In some cases, this shift in the concentration-time profile will result in different PK parameters for the test compound. Based on these observations, it is recommended that a consistent blood sampling method should be used for serial microsampling in discovery rat PK studies when testing multiple new chemical entities. If the rat tail vein sampling method is selected for PK screening, then conducting a bridging study on the lead compound is recommended to confirm that the rat PK obtained from JVC sampling is comparable to the tail-vein sampling. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Mass Spectrometric Rapid Diagnosis of Infectious Diseases.

    DTIC Science & Technology

    1980-01-01

    the analytical procedures to warrant reporting anew the whole analytical procedure. A. Sample Collection and Storage Procedure Urine samples were...positives or false-negatives. Next we have carried out a longitudinal study on urine samples obtained from groups of volunteer subjects vaccinated with...sterilization and storage procedures. 2. Developed new, simpler sample preparation techniques including one to handle tissue culture media. 3. Improved on the

  15. In vivo serial sampling of epididymal sperm in mice.

    PubMed

    Del Val, Gonzalo Moreno; Robledano, Patricia Muñoz

    2013-07-01

    This study was undertaken to refine the techniques of in vivo collection of sperm in the mouse. The principal objective was to offer a viable, safe and reliable method for serial collection of in vivo epididimary sperm through the direct puncture of the epididymis. Six C57Bl/6J males were subjected to the whole experiment. First we obtain a sperm sample of the right epididymis, and perform a vasectomy on the left side. This sample was used in an in vitro fertilization (IVF) experiment while the males were individually housed for 10 days to let them recover from the surgery, and then their fertility was tested with natural matings until we obtained a litter of each one. After that, the animals were subjected another time to the same process (sampling, recover and natural mating). The results of these experiments were a fertilization average value of 56.7%, and that all the males had a litter in the first month after the natural matings. This study documented the feasibility of the epididimary puncture technique to in vivo serial sampling of sperm in the mouse.

  16. Measurement of technetium-99 in Marshall Islands soil samples by ICP-MS

    PubMed

    Tagami; Uchida; Hamilton; Robison

    2000-07-01

    Extraction techniques for recovery of technetium-99 (99Tc) for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (MI) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq g(-1) dry weight (dw). The limit of detection for 99Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq g(-1) dw under standard operating conditions.

  17. Capillary blood sampling as an alternative to venipuncture in the assessment of serum 25 hydroxyvitamin D levels.

    PubMed

    Dayre McNally, J; Matheson, Loren A; Sankaran, Koravangattu; Rosenberg, Alan M

    2008-11-01

    This study compared 25-hydroxyvitamin D [25(OH)D] measurements in capillary and venous blood samples collected, respectively by fingerprick and venipuncture. Capillary blood for measuring 25(OH)D has potential advantages by reducing blood volume required (2mL versus 0.3mL for venipuncture and capillary sampling, respectively), facilitating blood collection for those populations in whom venipuncture is difficult (e.g. infants and children), improving patient convenience and reducing costs associated with phlebotomy. The results demonstrated a highly significant relationship between 25(OH)D levels in serum derived from venous and capillary blood samples (r(2)=0.901). Despite statistically higher 25(OH)D levels in fingerprick samples (108+/-9nmol/L) compared with venipuncture samples (90+/-7nmol/L), the correlation between venous and capillary samples provides support for this approach as a practical alternative to venipuncture for vitamin D determination. However, clinical application may require the incorporation of a correction factor for the assessment of insufficiency, and research studies should avoid using the two methods interchangeably. Studying vitamin D's role in health and disease requires collection techniques and measurement methods that are reliable, reproducible, easily accessible, inexpensive and minimally burdensome to the patient. The option to collect patient samples by fingerprick may facilitate the collection process.

  18. Urine sampling techniques in symptomatic primary-care patients: a diagnostic accuracy review.

    PubMed

    Holm, Anne; Aabenhus, Rune

    2016-06-08

    Choice of urine sampling technique in urinary tract infection may impact diagnostic accuracy and thus lead to possible over- or undertreatment. Currently no evidencebased consensus exists regarding correct sampling technique of urine from women with symptoms of urinary tract infection in primary care. The aim of this study was to determine the accuracy of urine culture from different sampling-techniques in symptomatic non-pregnant women in primary care. A systematic review was conducted by searching Medline and Embase for clinical studies conducted in primary care using a randomized or paired design to compare the result of urine culture obtained with two or more collection techniques in adult, female, non-pregnant patients with symptoms of urinary tract infection. We evaluated quality of the studies and compared accuracy based on dichotomized outcomes. We included seven studies investigating urine sampling technique in 1062 symptomatic patients in primary care. Mid-stream-clean-catch had a positive predictive value of 0.79 to 0.95 and a negative predictive value close to 1 compared to sterile techniques. Two randomized controlled trials found no difference in infection rate between mid-stream-clean-catch, mid-stream-urine and random samples. At present, no evidence suggests that sampling technique affects the accuracy of the microbiological diagnosis in non-pregnant women with symptoms of urinary tract infection in primary care. However, the evidence presented is in-direct and the difference between mid-stream-clean-catch, mid-stream-urine and random samples remains to be investigated in a paired design to verify the present findings.

  19. Detection of Cryptosporidium and Cyclospora Oocysts from Environmental Water for Drinking and Recreational Activities in Sarawak, Malaysia.

    PubMed

    Bilung, Lesley Maurice; Tahar, Ahmad Syatir; Yunos, Nur Emyliana; Apun, Kasing; Lim, Yvonne Ai-Lian; Nillian, Elexson; Hashim, Hashimatul Fatma

    2017-01-01

    Cryptosporidiosis and cyclosporiasis are caused by waterborne coccidian protozoan parasites of the genera Cryptosporidium and Cyclospora, respectively. This study was conducted to detect Cryptosporidium and Cyclospora oocysts from environmental water abstracted by drinking water treatment plants and recreational activities in Sarawak, Malaysia. Water samples (12 each) were collected from Sungai Sarawak Kanan in Bau and Sungai Sarawak Kiri in Batu Kitang, respectively. In addition, 6 water samples each were collected from Ranchan Recreational Park and UNIMAS Lake at Universiti Malaysia Sarawak, Kota Samarahan, respectively. Water physicochemical parameters were also recorded. All samples were concentrated by the iron sulfate flocculation method followed by the sucrose floatation technique. Cryptosporidium and Cyclospora were detected by modified Ziehl-Neelsen technique. Correlation of the parasites distribution with water physicochemical parameters was analysed using bivariate Pearson correlation. Based on the 24 total samples of environmental water abstracted by drinking water treatment plants, all the samples (24/24; 100%) were positive with Cryptosporidium , and only 2 samples (2/24; 8.33%) were positive with Cyclospora . Based on the 12 total samples of water for recreational activities, 4 samples (4/12; 33%) were positive with Cryptosporidium , while 2 samples (2/12; 17%) were positive with Cyclospora . Cryptosporidium oocysts were negatively correlated with dissolved oxygen (DO).

  20. Detection of Cryptosporidium and Cyclospora Oocysts from Environmental Water for Drinking and Recreational Activities in Sarawak, Malaysia

    PubMed Central

    Tahar, Ahmad Syatir; Yunos, Nur Emyliana; Apun, Kasing; Nillian, Elexson; Hashim, Hashimatul Fatma

    2017-01-01

    Cryptosporidiosis and cyclosporiasis are caused by waterborne coccidian protozoan parasites of the genera Cryptosporidium and Cyclospora, respectively. This study was conducted to detect Cryptosporidium and Cyclospora oocysts from environmental water abstracted by drinking water treatment plants and recreational activities in Sarawak, Malaysia. Water samples (12 each) were collected from Sungai Sarawak Kanan in Bau and Sungai Sarawak Kiri in Batu Kitang, respectively. In addition, 6 water samples each were collected from Ranchan Recreational Park and UNIMAS Lake at Universiti Malaysia Sarawak, Kota Samarahan, respectively. Water physicochemical parameters were also recorded. All samples were concentrated by the iron sulfate flocculation method followed by the sucrose floatation technique. Cryptosporidium and Cyclospora were detected by modified Ziehl-Neelsen technique. Correlation of the parasites distribution with water physicochemical parameters was analysed using bivariate Pearson correlation. Based on the 24 total samples of environmental water abstracted by drinking water treatment plants, all the samples (24/24; 100%) were positive with Cryptosporidium, and only 2 samples (2/24; 8.33%) were positive with Cyclospora. Based on the 12 total samples of water for recreational activities, 4 samples (4/12; 33%) were positive with Cryptosporidium, while 2 samples (2/12; 17%) were positive with Cyclospora. Cryptosporidium oocysts were negatively correlated with dissolved oxygen (DO). PMID:29234679

  1. An introduction to the processes, problems, and management of urban lakes

    USGS Publications Warehouse

    Britton, L.J.; Averett, R.C.; Ferreira, R.F.

    1975-01-01

    As lake studies become more common, sampling techniques for data collection need increased accuracy and consistency, in order to make meaningful comparisons between different lakes. Therefore, the report discusses the main factors involved in conducting lake studies. These factors include the types and frequency of measurements useful in lake reconnaissance studies and a review of literature on sampling equipment and techniques. A glossary of selected terms begins the report, which is intended for guideline use by urban planners and managers.

  2. A Visual Evaluation Study of Graph Sampling Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Fangyan; Zhang, Song; Wong, Pak C.

    2017-01-29

    We evaluate a dozen prevailing graph-sampling techniques with an ultimate goal to better visualize and understand big and complex graphs that exhibit different properties and structures. The evaluation uses eight benchmark datasets with four different graph types collected from Stanford Network Analysis Platform and NetworkX to give a comprehensive comparison of various types of graphs. The study provides a practical guideline for visualizing big graphs of different sizes and structures. The paper discusses results and important observations from the study.

  3. Impact of collection container material and holding times on sample integrity for mercury and methylmercury in water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riscassi, Ami L; Miller, Carrie L; Brooks, Scott C

    Mercury (Hg) and methylmercury (MeHg) concentrations in streamwater can vary on short timescales (hourly or less) during storm flow and on a diel cycle; the frequency and timing of sampling required to accurately characterize these dynamics may be difficult to accomplish manually. Automated sampling can assist in sample collection; however use has been limited for Hg and MeHg analysis due to stability concerns of trace concentrations during extended storage times. We examined the viability of using automated samplers with disposable low-density polyethylene (LDPE) sample bags to collect industrially contaminated streamwater for unfiltered and filtered Hg and MeHg analysis. Specifically wemore » investigated the effect of holding times ranging from hours to days on streamwater collected during baseflow and storm flow. Unfiltered and filtered Hg and MeHg concentrations decreased with increases in time prior to sample processing; holding times of 24 hours or less resulted in concentration changes (mean 11 7% different) similar to variability in duplicates collected manually during analogous field conditions (mean 7 10% different). Comparisons of samples collected with manual and automated techniques throughout a year for a wide range of stream conditions were also found to be similar to differences observed between duplicate grab samples. These results demonstrate automated sampling into LDPE bags with holding times of 24 hours or less can be effectively used to collect streamwater for Hg and MeHg analysis, and encourage the testing of these materials and methods for implementation in other aqueous systems where high-frequency sampling is warranted.« less

  4. Sediment pore-water toxicity test results and preliminary toxicity identification of post-landfall pore-water samples collected following the Deepwater Horizon oil release, Gulf of Mexico, 2010

    USGS Publications Warehouse

    Biedenbach, James M.; Carr, Robert S.

    2011-01-01

    Pore water from coastal beach and marsh sediments from the northern Gulf of Mexico, pre- and post-landfall of the Deepwater Horizon oil release, were collected and evaluated for toxicity with the sea urchin fertilization and embryological development assays. There were 17 pre-landfall samples and 49 post-landfall samples tested using both assays. Toxicity was determined in four pre-landfall sites and in seven post-landfall sites in one or both assays as compared to a known reference sediment pore-water sample collected in Aransas Bay, Texas. Further analysis and testing of five of the post-landfall toxic samples utilizing Toxicity Identification Evaluation techniques indicated that ammonia, and to a lesser extent metals, contributed to most, if not all, of the observed toxicity in four of the five samples. Results of one sample (MS-39) indicated evidence that ammonia, metals, and non-ionic organics were contributing to the observed toxicity.

  5. A comparison of liver sampling techniques in dogs.

    PubMed

    Kemp, S D; Zimmerman, K L; Panciera, D L; Monroe, W E; Leib, M S; Lanz, O I

    2015-01-01

    The liver sampling technique in dogs that consistently provides samples adequate for accurate histopathologic interpretation is not known. To compare histopathologic results of liver samples obtained by punch, cup, and 14 gauge needle to large wedge samples collected at necropsy. Seventy dogs undergoing necropsy. Prospective study. Liver specimens were obtained from the left lateral liver lobe with an 8 mm punch, a 5 mm cup, and a 14 gauge needle. After sample acquisition, two larger tissue samples were collected near the center of the left lateral lobe to be used as a histologic standard for comparison. Histopathologic features and numbers of portal triads in each sample were recorded. The mean number of portal triads obtained by each sampling method were 2.9 in needle samples, 3.4 in cup samples, 12 in punch samples, and 30.7 in the necropsy samples. The diagnoses in 66% of needle samples, 60% of cup samples, and 69% of punch samples were in agreement with the necropsy samples, and these proportions were not significantly different from each other. The corresponding kappa coefficients were 0.59 for needle biopsies, 0.52 for cup biopsies, and 0.62 for punch biopsies. The histopathologic interpretation of a liver sample in the dog is unlikely to vary if the liver biopsy specimen contains at least 3-12 portal triads. However, in comparison large necropsy samples, the accuracy of all tested methods was relatively low. Copyright © 2014 by the American College of Veterinary Internal Medicine.

  6. Enhanced Conformational Sampling Using Replica Exchange with Collective-Variable Tempering.

    PubMed

    Gil-Ley, Alejandro; Bussi, Giovanni

    2015-03-10

    The computational study of conformational transitions in RNA and proteins with atomistic molecular dynamics often requires suitable enhanced sampling techniques. We here introduce a novel method where concurrent metadynamics are integrated in a Hamiltonian replica-exchange scheme. The ladder of replicas is built with different strengths of the bias potential exploiting the tunability of well-tempered metadynamics. Using this method, free-energy barriers of individual collective variables are significantly reduced compared with simple force-field scaling. The introduced methodology is flexible and allows adaptive bias potentials to be self-consistently constructed for a large number of simple collective variables, such as distances and dihedral angles. The method is tested on alanine dipeptide and applied to the difficult problem of conformational sampling in a tetranucleotide.

  7. Dosimeter for monitoring vapors and aerosols of organic compounds

    DOEpatents

    Vo-Dinh, Tuan

    1987-01-01

    A dosimeter is provided for collecting and detecting vapors and aerosols of organic compounds. The dosimeter comprises a lightweight, passive device that can be conveniently worn by a person as a badge or placed at a stationary location. The dosimeter includes a sample collector comprising a porous web treated with a chemical for inducing molecular displacement and enhancing phosphorescence. Compounds are collected onto the web by molecular diffusion. The web also serves as the sample medium for detecting the compounds by a room temperature phosphorescence technique.

  8. Automatic robotic arm operations and sampling in near zero gravity environment - functional tests results from Phobos-Grunt mission

    NASA Astrophysics Data System (ADS)

    Kozlova, Tatiana; Karol Seweryn, D..; Grygorczuk, Jerzy; Kozlov, Oleg

    The sample return missions have made a very significant progress to understanding of geology, the extra-terrestrial materials, processes occurring on surface and subsurface level, as well as of interactions between such materials and mechanisms operating there. The various sample return missions in the past (e.g. Apollo missions, Luna missions, Hayabusa mission) have provided scientists with samples of extra-terrestrial materials allowing to discover answers to critical scientific questions concerning the origin and evolution of the Solar System. Several new missions are currently planned: sample return missions, e.g Russian Luna-28, ESA Phootprint and MarcoPolo-R as well as both robotic and manned exploration missions to the Moon and Mars. One of the key challenges in such missions is the reliable sampling process which can be achieved by using many different techniques, e.g. static excavating technique (scoop), core drilling, sampling using dynamic mechanisms (penetrators), brushes and pneumatic systems. The effectiveness of any sampling strategy depends on many factors, including the required sample size, the mechanical and chemical soil properties (cohesive, hard or porous regolith, stones), the environment conditions (gravity, temperature, pressure, radiation). Many sampling mechanism have been studied, designed and built in the past, two techniques to collect regolith samples were chosen for the Phobos-Grunt mission. The proposed system consisted of a robotic arm with a 1,2m reach beyond the lander (IKI RAN); a tubular sampling device designed for collecting both regolith and small rock fragments (IKI RAN); the CHOMIK device (CBK PAN) - the low velocity penetrator with a single-sample container for collecting samples from the rocky surface. The functional tests were essential step in robotic arm, sampling device and CHOMIK device development process in the frame of Phobos-Grunt mission. Three major results were achieved: (i) operation scenario for autonomous sampling; (ii) technical characteristics of both devices, i.e. progress cycles of CHOMIK device in different materials and torque in the manipulator joints during sampling operations; (iii) confirmation of applicability of both devices to perform such type of tasks. The phases in operational scenario were prepared to meet mission and system requirements mainly connected with: (i) environment (near zero gravity, vacuum, dust), (ii) safety and (iii) to avoid common operation of both devices at the same time.

  9. Demonstration/Validation of Incremental Sampling at Two Diverse Military Ranges and Development of an Incremental Sampling Tool

    DTIC Science & Technology

    2010-06-01

    Sampling (MIS)? • Technique of combining many increments of soil from a number of points within exposure area • Developed by Enviro Stat (Trademarked...Demonstrating a reliable soil sampling strategy to accurately characterize contaminant concentrations in spatially extreme and heterogeneous...into a set of decision (exposure) units • One or several discrete or small- scale composite soil samples collected to represent each decision unit

  10. Method for collecting spores from a mold

    DOEpatents

    Au, Frederick H. F.; Beckert, Werner F.

    1977-01-01

    A technique and apparatus used therewith for determining the uptake of plutonium and other contaminants by soil microorganisms which, in turn, gives a measure of the plutonium and/or other contaminants available to the biosphere at that particular time. A measured quantity of uncontaminated spores of a selected mold is added to a moistened sample of the soil to be tested. The mixture is allowed to sit a predetermined number of days under specified temperature conditions. An agar layer is then applied to the top of the sample. After three or more days, when spores of the mold growing in the sample have formed, the spores are collected by a miniature vacuum collection apparatus operated under preselected vacuum conditions, which collect only the spores with essentially no contamination by mycelial fragments or culture medium. After collection, the fungal spores are dried and analyzed for the plutonium and/or other contaminants. The apparatus is also suitable for collection of pollen, small insects, dust and other small particles, material from thin-layer chromatography plates, etc.

  11. Method for Extraction and Multielement Analysis of Hypogymnia Physodes Samples from the Athabasca Oil Sands Region

    EPA Science Inventory

    A microwave-assisted digestion technique followed by ICPMS (inductively coupled plasma-mass spectrometry) analysis was used to measure concentrations of 43 elements in Hypogymnia physodes samples collected in the Athabasca Oil Sands Region (AOSR) of northern Alberta, Canad...

  12. TO PURGE OR NOT TO PURGE? VOC CONCENTRATION CHANGES DURING LINE VOLUME PURGING

    EPA Science Inventory

    Soil vapor surveys are commonly used as a screening technique to delineate volatile organic compound (VOC) contaminant plumes and provide information for soil sampling plans. Traditionally, three purge volumes of vapor are removed before a sample is collected. One facet of this s...

  13. Determination of Movement Sense in Mylonites.

    ERIC Educational Resources Information Center

    Simpson, Carol

    1986-01-01

    Describes how mylonite samples can be used to determine the sense of shear. Several sample collection techniques are presented. Criteria for shear sense determination are outlined and discussed so that they can be recognized and interpreted by students familiar with the use of a compass and a petrographic microscope. (TW)

  14. Improved technique that allows the performance of large-scale SNP genotyping on DNA immobilized by FTA technology.

    PubMed

    He, Hongbin; Argiro, Laurent; Dessein, Helia; Chevillard, Christophe

    2007-01-01

    FTA technology is a novel method designed to simplify the collection, shipment, archiving and purification of nucleic acids from a wide variety of biological sources. The number of punches that can normally be obtained from a single specimen card are often however, insufficient for the testing of the large numbers of loci required to identify genetic factors that control human susceptibility or resistance to multifactorial diseases. In this study, we propose an improved technique to perform large-scale SNP genotyping. We applied a whole genome amplification method to amplify DNA from buccal cell samples stabilized using FTA technology. The results show that using the improved technique it is possible to perform up to 15,000 genotypes from one buccal cell sample. Furthermore, the procedure is simple. We consider this improved technique to be a promising methods for performing large-scale SNP genotyping because the FTA technology simplifies the collection, shipment, archiving and purification of DNA, while whole genome amplification of FTA card bound DNA produces sufficient material for the determination of thousands of SNP genotypes.

  15. Comparison of conventional PCR, quantitative PCR, bacteriological culture and the Warthin Starry technique to detect Leptospira spp. in kidney and liver samples from naturally infected sheep from Brazil.

    PubMed

    Fornazari, Felipe; da Silva, Rodrigo Costa; Richini-Pereira, Virginia Bodelão; Beserra, Hugo Enrique Orsini; Luvizotto, Maria Cecília Rui; Langoni, Helio

    2012-09-01

    Leptospirosis is an infectious disease of worldwide importance. The development of diagnostic techniques allows sick animals to be identified, reservoirs to be eliminated and the disease prevented and controlled. The present study aimed to compare different techniques for diagnosing leptospirosis in sheep. Samples of kidney, liver and blood were collected from 465 animals that originated from a slaughterhouse. The sera were analyzed by the Microscopic Agglutination Test (MAT), and kidney and liver samples of seropositive animals were analyzed using four techniques: bacteriological culture, the Warthin Starry (WS) technique, conventional PCR (cPCR), and quantitative PCR (qPCR). With the MAT, 21 animals were positive (4.5%) to serovars Hardjo (n=12), Hebdomadis (n=5), Sentot (n=2), Wolfii (n=1) and Shermani (n=1). Titers were 100 (n=10), 200 (n=2), 400 (n=6) and 1600 (n=3). No animal was positive by bacteriological culture; four animals were positive by the WS technique in kidney samples; six animals were positive by cPCR in kidney samples; and 11 animals were positive by qPCR, eight of which in kidney samples and three in liver. The bacterial quantification revealed a median of 4.3 bacteria/μL in liver samples and 36.6 bacteria/μL in kidney samples. qPCR presented the highest sensitivity among the techniques, followed by cPCR, the WS technique and bacteriological culture. These results indicate that sheep can carry leptospires of the Sejroe serogroup, and demonstrate the efficiency of quantitative PCR to detect Leptospira spp. in tissue samples. Published by Elsevier B.V.

  16. Sampling western spruce budworm by counting larvae on lower crown branches.

    Treesearch

    R.R. Mason; B.E. Wickman; H.G. Paul

    1989-01-01

    A technique is described for sampling spruce budworm larvae after bud flush by nondestructively beating branches in the lower crown. Sample data were collected from 32 plots representing a wide range of budworm densities. Statistical analyses indicated that larvae were less aggregated in the lower crown than at the same density in the middle crown. In an independent...

  17. Sampling tree tops by helicopter...special pole pruner cuts branchlets

    Treesearch

    John F. Wear; Robert G. Winterfeld

    1966-01-01

    A new technique for sampling tops of tall Douglas-fir trees by using a special pole pruner from a helicopter has been developed and field-tested. Thee pole pruner cuts and holds a branchlet. Foliage samples collected will be compared by spectral analysis to show the type of aerial imagery that best differentiates healthy trees from those attacked by root rot.

  18. Non-uniform sampling: post-Fourier era of NMR data collection and processing.

    PubMed

    Kazimierczuk, Krzysztof; Orekhov, Vladislav

    2015-11-01

    The invention of multidimensional techniques in the 1970s revolutionized NMR, making it the general tool of structural analysis of molecules and materials. In the most straightforward approach, the signal sampling in the indirect dimensions of a multidimensional experiment is performed in the same manner as in the direct dimension, i.e. with a grid of equally spaced points. This results in lengthy experiments with a resolution often far from optimum. To circumvent this problem, numerous sparse-sampling techniques have been developed in the last three decades, including two traditionally distinct approaches: the radial sampling and non-uniform sampling. This mini review discusses the sparse signal sampling and reconstruction techniques from the point of view of an underdetermined linear algebra problem that arises when a full, equally spaced set of sampled points is replaced with sparse sampling. Additional assumptions that are introduced to solve the problem, as well as the shape of the undersampled Fourier transform operator (visualized as so-called point spread function), are shown to be the main differences between various sparse-sampling methods. Copyright © 2015 John Wiley & Sons, Ltd.

  19. SSAGES: Software Suite for Advanced General Ensemble Simulations.

    PubMed

    Sidky, Hythem; Colón, Yamil J; Helfferich, Julian; Sikora, Benjamin J; Bezik, Cody; Chu, Weiwei; Giberti, Federico; Guo, Ashley Z; Jiang, Xikai; Lequieu, Joshua; Li, Jiyuan; Moller, Joshua; Quevillon, Michael J; Rahimi, Mohammad; Ramezani-Dakhel, Hadi; Rathee, Vikramjit S; Reid, Daniel R; Sevgen, Emre; Thapar, Vikram; Webb, Michael A; Whitmer, Jonathan K; de Pablo, Juan J

    2018-01-28

    Molecular simulation has emerged as an essential tool for modern-day research, but obtaining proper results and making reliable conclusions from simulations requires adequate sampling of the system under consideration. To this end, a variety of methods exist in the literature that can enhance sampling considerably, and increasingly sophisticated, effective algorithms continue to be developed at a rapid pace. Implementation of these techniques, however, can be challenging for experts and non-experts alike. There is a clear need for software that provides rapid, reliable, and easy access to a wide range of advanced sampling methods and that facilitates implementation of new techniques as they emerge. Here we present SSAGES, a publicly available Software Suite for Advanced General Ensemble Simulations designed to interface with multiple widely used molecular dynamics simulations packages. SSAGES allows facile application of a variety of enhanced sampling techniques-including adaptive biasing force, string methods, and forward flux sampling-that extract meaningful free energy and transition path data from all-atom and coarse-grained simulations. A noteworthy feature of SSAGES is a user-friendly framework that facilitates further development and implementation of new methods and collective variables. In this work, the use of SSAGES is illustrated in the context of simple representative applications involving distinct methods and different collective variables that are available in the current release of the suite. The code may be found at: https://github.com/MICCoM/SSAGES-public.

  20. A Technique for Thermal Desorption Analyses Suitable for Thermally-Labile, Volatile Compounds.

    PubMed

    Alborn, Hans T

    2018-02-01

    Many plant and insect interactions are governed by odors released by the plants or insects and there exists a continual need for new or improved methods to collect and identify these odors. Our group has for some time studied below-ground, plant-produced volatile signals affecting nematode and insect behavior. The research requires repeated sampling of volatiles of intact plant/soil systems in the laboratory as well as the field with the help of probes to minimize unwanted effects on the systems we are studying. After evaluating solid adsorbent filters with solvent extraction or solid phase micro extraction fiber sample collection, we found dynamic sampling of small air volumes on Tenax TA filters followed by thermal desorption sample introduction to be the most suitable analytical technique for our applications. Here we present the development and evaluation of a low-cost and relatively simple thermal desorption technique where a cold trap cooled with liquid carbon dioxide is added as an integral part of a splitless injector. Temperature gradient-based focusing and low thermal mass minimizes aerosol formation and eliminates the need for flash heating, resulting in low sample degradation comparable to solvent-based on-column injections. Additionally, since the presence of the cold trap does not affect normal splitless injections, on-the-fly switching between splitless and thermal desorption modes can be used for external standard quantification.

  1. Collective Behavior of Water on Platinum

    NASA Astrophysics Data System (ADS)

    Limmer, David; Willard, Adam; Chandler, David

    2012-02-01

    We present the results of molecular dynamics simulations of a interface between water and a platinum electrode. Using importance sampling techniques we probe a variety of collective phenomenon that emerge at the interface. We consider platinum electrodes with two different geometries and discuss how different behaviors result from a competition between geometrical frustration and favorable local interactions.

  2. Effects of stimulation technique, anatomical region and time on human sweat lipid mediator profiles.

    USDA-ARS?s Scientific Manuscript database

    Few studies compare sampling protocol effect on sweat composition. Here we evaluate the impact of sweat stimulation mode and site of collection on lipid mediator composition. Sweat from healthy males (n = 7) was collected weekly for three weeks from the volar forearm following either pilocarpine ion...

  3. A geochemical sampling technique for use in areas of active alpine glaciation: an application from the central Alaska Range

    USGS Publications Warehouse

    Stephens, G.C.; Evenson, E.B.; Detra, D.E.

    1990-01-01

    In mountainous regions containing extensive glacier systems there is a lack of suitable material for conventional geochemical sampling. As a result, in most geochemical sampling programs a few stream-sediment samples collected at, or near, the terminus of valley glaciers are used to evaluate the mineral potential of the glaciated area. We have developed and tested a technique which utilizes the medial moraines of valley glaciers for systematic geochemical exploration of the glacial catchment area. Moraine sampling provides geochemical information that is site-specific in that geochemical anomalies can be traced directly up-ice to bedrock sources. Traverses were made across the Trident and Susitna glaciers in the central Alaska Range where fine-grained (clay to sand size) samples were collected from each medial moraine. These samples were prepared and chemically analyzed to determine the concentration of specific elements. Fifty pebbles were collected at each moraine for archival purposes and for subsequent lithologic identification. Additionally, fifty cobbles and fifty boulders were examined and described at each sample site to determine the nature and abundance of lithologies present in the catchment area, the extent and nature of visible mineralization, the presence and intensity of hydrothermal alteration and the existence of veins, dikes and other minor structural features. Results from the central Alaska Range have delineated four distinct multi-element anomalies which are a response to potential mineralization up-ice from the medial moraine traverse. By integrating the lithologic, mineralogical and geochemical data the probable geological setting of the geochemical anomalies is determined. ?? 1990.

  4. Sampling of Atmospheric Precipitation and Deposits for Analysis of Atmospheric Pollution

    PubMed Central

    Skarżyńska, K.; Polkowska, Ż; Namieśnik, J.

    2006-01-01

    This paper reviews techniques and equipment for collecting precipitation samples from the atmosphere (fog and cloud water) and from atmospheric deposits (dew, hoarfrost, and rime) that are suitable for the evaluation of atmospheric pollution. It discusses the storage and preparation of samples for analysis and also presents bibliographic information on the concentration ranges of inorganic and organic compounds in the precipitation and atmospheric deposit samples. PMID:17671615

  5. A modified method using the SonoPrep ultrasonic skin permeation system for sampling human interstitial fluid is compatible with proteomic techniques.

    PubMed

    Lecomte, Marie M J; Atkinson, Kelly R; Kay, Daniel P; Simons, Joanne L; Ingram, John R

    2013-02-01

    The use of biomarkers in skin is a novel diagnostic tool. Interstitial fluid (ISF) from skin provides a snapshot of proteins secreted at the time of sampling giving insights into the patient's health status. A minimally invasive technique for the transdermal collection of human ISF proteins. A low frequency ultrasonic skin permeation device (SonoPrep ultrasonic skin permeation system) was used to produce micropores in the stratum corneum through which ISF was extracted using a portable pulsed vacuum ISF collection device. On average, protein concentrations recovered ranged between 0.064 and 4.792 μg/μL (mean 1.258 μg/μL). Two-dimensional gel electrophoresis revealed that this sample type was amenable to this type of analysis. Gel images indicated that both highly abundant proteins and lower abundance proteins were isolated from the skin. Western blot analysis confirmed the presence of proteins commonly found in plasma and the epidermis. A minimally invasive method for the transdermal recovery of ISF proteins has been developed. We have demonstrated that ISF samples obtained using this approach can be analysed with proteomic techniques, such as two-dimensional gel electrophoresis and western blots, providing another tool for the identification of disease specific protein biomarkers. © 2012 John Wiley & Sons A/S.

  6. Real time PCR to detect the environmental faecal contamination by Echinococcus multilocularis from red fox stools.

    PubMed

    Knapp, Jenny; Millon, Laurence; Mouzon, Lorane; Umhang, Gérald; Raoul, Francis; Ali, Zeinaba Said; Combes, Benoît; Comte, Sébastien; Gbaguidi-Haore, Houssein; Grenouillet, Frédéric; Giraudoux, Patrick

    2014-03-17

    The oncosphere stage of Echinococcus multilocularis in red fox stools can lead, after ingestion, to the development of alveolar echinococcosis in the intermediate hosts, commonly small mammals and occasionally humans. Monitoring animal infection and environmental contamination is a key issue in public health surveillance. We developed a quantitative real-time PCR technique (qPCR) to detect and quantify E. multilocularis DNA released in fox faeces. A qPCR technique using a hydrolysis probe targeting part of the mitochondrial gene rrnL was assessed on (i) a reference collection of stools from 57 necropsied foxes simultaneously investigated using the segmental sedimentation and counting technique (SSCT) (29 positive for E. multilocularis worms and 28 negative animals for the parasite); (ii) a collection of 114 fox stools sampled in the field: two sets of 50 samples from contrasted endemic regions in France and 14 from an E. multilocularis-free area (Greenland). Of the negative SSCT controls, 26/28 were qPCR-negative and two were weakly positive. Of the positive SSCT foxes, 25/29 samples were found to be positive by qPCR. Of the field samples, qPCR was positive in 21/50 (42%) and 5/48 (10.4%) stools (2 samples inhibited), originating respectively from high and low endemic areas. In faeces, averages of 0.1 pg/μl of DNA in the Jura area and 0.7 pg/μl in the Saône-et-Loire area were detected. All qPCR-positive samples were confirmed by sequencing. The qPCR technique developed here allowed us to quantify environmental E. multilocularis contamination by fox faeces by studying the infectious agent directly. No previous study had performed this test in a one-step reaction. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Verification and characterization of chromosome duplication in haploid maize.

    PubMed

    de Oliveira Couto, E G; Resende Von Pinho, E V; Von Pinho, R G; Veiga, A D; de Carvalho, M R; de Oliveira Bustamante, F; Nascimento, M S

    2015-06-26

    Doubled haploid technology has been used by various private companies. However, information regarding chromosome duplication methodologies, particularly those concerning techniques used to identify duplication in cells, is limited. Thus, we analyzed and characterized artificially doubled haploids using microsatellites molecular markers, pollen viability, and flow cytometry techniques. Evaluated material was obtained using two different chromosome duplication protocols in maize seeds considered haploids, resulting from the cross between the haploid inducer line KEMS and 4 hybrids (GNS 3225, GNS 3032, GNS 3264, and DKB 393). Fourteen days after duplication, plant samples were collected and assessed by flow cytometry. Further, the plants were transplanted to a field, and samples were collected for DNA analyses using microsatellite markers. The tassels were collected during anthesis for pollen viability analyses. Haploid, diploid, and mixoploid individuals were detected using flow cytometry, demonstrating that this technique was efficient for identifying doubled haploids. The microsatellites markers were also efficient for confirming the ploidies preselected by flow cytometry and for identifying homozygous individuals. Pollen viability showed a significant difference between the evaluated ploidies when the Alexander and propionic-carmin stains were used. The viability rates between the plodies analyzed show potential for fertilization.

  8. A literature survey of information on well installation and sample collection procedures used in investigations of ground-water contamination by organic compounds

    USGS Publications Warehouse

    Dumouchelle, D.H.; Lynch, E.A.; Cummings, T.R.

    1990-01-01

    A survey of literature on well installation and water-quality sampling, particularly as they relate to investigations of ground-water contamination by organic compounds, has been conducted. Library card files and computerized data bases were searched to identify journal articles, conference proceedings, technical reports, books, and other publications. Pertinent information has been extracted from 105 references; each reference is listed in a bibliography. Material contained in the report is organized by topical categories that include drilling methods and equipment, well construction, well development, sampling materials and equipment, decontamination of equipment, and sampling techniques and procedures. Unpublished data of the U.S. Geological Survey on sample collection are briefly cited also.

  9. KRAS detection in colonic tumors by DNA extraction from FTA paper: the molecular touch-prep.

    PubMed

    Petras, Melissa L; Lefferts, Joel A; Ward, Brian P; Suriawinata, Arief A; Tsongalis, Gregory J

    2011-12-01

    DNA isolated from formalin-fixed paraffin-embedded (FFPE) tissue is usually more degraded and contains more polymerase chain reaction (PCR) inhibitors than DNA isolated from nonfixed tissue. In addition, the tumor size and cellular heterogeneity found in tissue sections can often impact testing for molecular biomarkers. As a potential remedy to this situation, we evaluated the use of Whatman FTA paper cards for collection of colorectal tumor samples before tissue fixation and for isolation of DNA for use in a real-time PCR-based KRAS mutation assay. Eleven colon tumor samples were collected by making a cut into the fresh tumor and applying the Whatman FTA paper to the cut surface. Matched FFPE tissue blocks from these tumors were also collected for comparison. KRAS mutation analysis was carried out using the Applied Biosystems 7500 Fast Real-time PCR System using 7 independent custom TaqMan PCR assays. Of the 11 colon tumors sampled, 6 were positive for KRAS mutations in both the Whatman FTA paper preparations and corresponding FFPE samples. Whatman FTA paper cards for collection of colorectal tumor samples before tissue fixation and for isolation of DNA have many advantages including ease of use, intrinsic antimicrobial properties, long storage potential (stability of DNA over time), and a faster turnaround time for results. Extracted DNA should be suitable for most molecular diagnostic assays that use PCR techniques. This novel means of DNA preservation from surgical specimens would benefit from additional study and validation as a dependable and practical technique to preserve specimens for molecular testing.

  10. Molecular techniques to distinguish morphologically similar Hydrilla verticillata, Egeria densa, Elodea nuttallii, and Elodea canadensis

    USGS Publications Warehouse

    Rybicki, Nancy B.; Kirshtein, Julie D.; Voytek, Mary A.

    2013-01-01

    The four submerged aquatic species, hydrilla (Hydrilla verticillata [monoecious and dioecious]), Brazilian waterweed (Egeria densa), Canadian waterweed (Elodea canadensis), and western waterweed (Elodea nuttallii), are difficult to positively identify because of their morphological similarity to each other, resulting in possible misidentification. This limits our ability to understand their past and present distribution, which is important in aquatic plant management. We investigated a molecular technique to identify these species, which are problematic because of their invasive nature on multiple continents. Approximately 100 samples of these species, ranging in age from 40-yr-old herbarium samples to recently collected plants, were collected from regions across the United States. The distribution and range of the samples collected in this research were compared to those reported in the literature. We confirmed information on the current wide distribution of both hydrilla biotypes in the United States and discovered that hydrilla had actually invaded the waterways near Washington, DC 6 yr earlier than originally reported. In addition, we found evidence of the confusion, dating back to the 1980s, between Canadian waterweed and western waterweed in the mid-Atlantic region of the United States. Canadian waterweed was previously reported as common and western waterweed as rare; however, our samples indicate the opposite is true. This information indicates there is a need for investigators to anticipate the spread of hydrilla populations to northern U.S. waterways, where it will compete with existing plant species, including Canadian and western waterweeds. Our ability to confirm distribution and pace of spread of invasive and noninvasive species will improve with increased application of molecular techniques.

  11. Comparison of three methods of sampling trout blood for measurements of hematocrit

    USGS Publications Warehouse

    Steucke, Erwin W.; Schoettger, Richard A.

    1967-01-01

    Trout blood is frequently collected for hematocrit measurements by excising the caudal fin (Snieszko, 1960), but this technique is impractical if valuable fish are to be sampled or if repeated observations are desired. Schiffman (1959) and Snieszko (1960) collected blood from the dorsal aorta and the heart, but these methods are relatively slow and require the preparation of needles and syringes. The use of pointed capillary tubes for cardiac punctures increases the speed of sampling, but body fluids may dilute the blood (Perkins, 1957; Larsen and Snieszko, 1961; and Normandau, 1962). There is need for methods of sampling which are rapid and which neither influence hematological determinations nor harm the fish.

  12. Atmospheric Carbon Dioxide Mixing Ratios from the NOAA CMDL Carbon Cycle Cooperative Global Air Sampling Network (2009)

    DOE Data Explorer

    Conway, Thomas [NOAA Climate Monitoring and Diagnostics Laboratory, Boulder, CO (USA); Tans, Pieter [NOAA Climate Monitoring and Diagnostics Laboratory, Boulder, CO (USA)

    2009-01-01

    The National Oceanic and Atmospheric Administration's Climate Monitoring and Diagnostics Laboratory (NOAA/CMDL) has measured CO2 in air samples collected weekly at a global network of sites since the late 1960s. Atmospheric CO2 mixing ratios reported in these files were measured by a nondispersive infrared absorption technique in air samples collected in glass flasks. All CMDL flask samples are measured relative to standards traceable to the World Meteorological Organization (WMO) CO2 mole fraction scale. These measurements constitute the most geographically extensive, carefully calibrated, internally consistent atmospheric CO2 data set available and are essential for studies aimed at better understanding the global carbon cycle budget.

  13. Influence of Meibomian Gland Expression Methods on Human Lipid Analysis Results.

    PubMed

    Kunnen, Carolina M E; Brown, Simon H J; Lazon de la Jara, Percy; Holden, Brien A; Blanksby, Stephen J; Mitchell, Todd W; Papas, Eric B

    2016-01-01

    To compare the lipid composition of human meibum across three different meibum expression techniques. Meibum was collected from five healthy non-contact lens wearers (aged 20-35 years) after cleaning the eyelid margin using three meibum expression methods: cotton buds (CB), meibomian gland evaluator (MGE) and meibomian gland forceps (MGF). Meibum was also collected using cotton buds without cleaning the eyelid margin (CBn). Lipids were analyzed by chip-based, nano-electrospray mass spectrometry (ESI-MS). Comparisons were made using linear mixed models. Tandem MS enabled identification and quantification of over 200 lipid species across ten lipid classes. There were significant differences between collection techniques in the relative quantities of polar lipids obtained (P<.05). The MGE method returned smaller polar lipid quantities than the CB approaches. No significant differences were found between techniques for nonpolar lipids. No significant differences were found between cleaned and non-cleaned eyelids for polar or nonpolar lipids. Meibum expression technique influences the relative amount of phospholipids in the resulting sample. The highest amounts of phospholipids were detected with the CB approaches and the lowest with the MGE technique. Cleaning the eyelid margin prior to expression was not found to affect the lipid composition of the sample. This may be a consequence of the more forceful expression resulting in cell membrane contamination or higher risk of tear lipid contamination as a result of reflex tearing. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Characterization of the March 2017 Tank 15 Waste Removal Slurry Sample (Combination of Slurry Samples HTF-15-17-28 and HTF-15-17-29)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reboul, S. H.; King, W. D.; Coleman, C. J.

    2017-05-09

    Two March 2017 Tank 15 slurry samples (HTF-15-17-28 and HTF-15-17-29) were collected during the second bulk waste removal campaign and submitted to SRNL for characterization. At SRNL, the two samples were combined and then characterized by a series of physical, elemental, radiological, and ionic analysis methods. Sludge settling as a function of time was also quantified. The characterization results reported in this document are consistent with expectations based upon waste type, process knowledge, comparisons between alternate analysis techniques, and comparisons with the characterization results obtained for the November 2016 Tank 15 slurry sample (the sample collected during the first bulkmore » waste removal campaign).« less

  15. A Comparison of Honey Bee-Collected Pollen From Working Agricultural Lands Using Light Microscopy and ITS Metabarcoding.

    PubMed

    Smart, M D; Cornman, R S; Iwanowicz, D D; McDermott-Kubeczko, M; Pettis, J S; Spivak, M S; Otto, C R V

    2017-02-01

    Taxonomic identification of pollen has historically been accomplished via light microscopy but requires specialized knowledge and reference collections, particularly when identification to lower taxonomic levels is necessary. Recently, next-generation sequencing technology has been used as a cost-effective alternative for identifying bee-collected pollen; however, this novel approach has not been tested on a spatially or temporally robust number of pollen samples. Here, we compare pollen identification results derived from light microscopy and DNA sequencing techniques with samples collected from honey bee colonies embedded within a gradient of intensive agricultural landscapes in the Northern Great Plains throughout the 2010-2011 growing seasons. We demonstrate that at all taxonomic levels, DNA sequencing was able to discern a greater number of taxa, and was particularly useful for the identification of infrequently detected species. Importantly, substantial phenological overlap did occur for commonly detected taxa using either technique, suggesting that DNA sequencing is an appropriate, and enhancing, substitutive technique for accurately capturing the breadth of bee-collected species of pollen present across agricultural landscapes. We also show that honey bees located in high and low intensity agricultural settings forage on dissimilar plants, though with overlap of the most abundantly collected pollen taxa. We highlight practical applications of utilizing sequencing technology, including addressing ecological issues surrounding land use, climate change, importance of taxa relative to abundance, and evaluating the impact of conservation program habitat enhancement efforts. Published by Oxford University Press on behalf of Entomological Society of America 2016. This work is written by US Government employees and is in the public domain in the US.

  16. Adaptation of Laser Microdissection Technique for the Study of a Spontaneous Metastatic Mammary Carcinoma Mouse Model by NanoString Technologies

    PubMed Central

    Saylor, Karen L.; Anver, Miriam R.; Salomon, David S.; Golubeva, Yelena G.

    2016-01-01

    Laser capture microdissection (LCM) of tissue is an established tool in medical research for collection of distinguished cell populations under direct microscopic visualization for molecular analysis. LCM samples have been successfully analyzed in a number of genomic and proteomic downstream molecular applications. However, LCM sample collection and preparation procedure has to be adapted to each downstream analysis platform. In this present manuscript we describe in detail the adaptation of LCM methodology for the collection and preparation of fresh frozen samples for NanoString analysis based on a study of a model of mouse mammary gland carcinoma and its lung metastasis. Our adaptation of LCM sample preparation and workflow to the requirements of the NanoString platform allowed acquiring samples with high RNA quality. The NanoString analysis of such samples provided sensitive detection of genes of interest and their associated molecular pathways. NanoString is a reliable gene expression analysis platform that can be effectively coupled with LCM. PMID:27077656

  17. Description of Student’s Metacognitive Ability in Understanding and Solving Mathematics Problem

    NASA Astrophysics Data System (ADS)

    Ahmad, Herlina; Febryanti, Fatimah; Febryanti, Fatimah; Muthmainnah

    2018-01-01

    This research was conducted qualitative which was aim to describe metacognitive ability to understand and solve the problems of mathematics. The subject of the research was the first year students at computer and networking department of SMK Mega Link Majene. The sample was taken by purposive sampling technique. The data obtained used the research instrument based on the form of students achievements were collected by using test of student’s achievement and interview guidance. The technique of collecting data researcher had observation to ascertain the model that used by teacher was teaching model of developing metacognitive. The technique of data analysis in this research was reduction data, presentation and conclusion. Based on the whole findings in this study it was shown that student’s metacognitive ability generally not develops optimally. It was because of limited scope of the materials, and cognitive teaching strategy handled by verbal presentation and trained continuously in facing cognitive tasks, such as understanding and solving problem.

  18. Concurrent Ultrasonic Tomography and Acoustic Emission in Solid Materials

    NASA Astrophysics Data System (ADS)

    Chow, Thomas M.

    A series of experiments were performed to detect stress induced changes in the elastic properties of various solid materials. A technique was developed where these changes were monitored concurrently by two methods, ultrasonic tomography and acoustic emission monitoring. This thesis discusses some experiments in which acoustic emission (AE) and ultrasonic tomography were performed on various samples of solid materials including rocks, concrete, metals, and fibre reinforced composites. Three separate techniques were used to induce stress in these samples. Disk shaped samples were subject to stress via diametral loading using an indirect tensile test geometry. Cylindrical samples of rocks and concrete were subject to hydraulic fracture tests, and rectangular samples of fibre reinforced composite were subject to direct tensile loading. The majority of the samples were elastically anisotropic. Full waveform acoustic emission and tomographic data were collected while these samples were under load to give information concerning changes in the structure of the material as it was undergoing stress change and/or failure. Analysis of this data indicates that AE and tomographic techniques mutually compliment each other to give a view of the stress induced elastic changes in the tested samples.

  19. Collection of Aerosolized Human Cytokines Using Teflon® Filters

    PubMed Central

    McKenzie, Jennifer H.; McDevitt, James J.; Fabian, M. Patricia; Hwang, Grace M.; Milton, Donald K.

    2012-01-01

    Background Collection of exhaled breath samples for the analysis of inflammatory biomarkers is an important area of research aimed at improving our ability to diagnose, treat and understand the mechanisms of chronic pulmonary disease. Current collection methods based on condensation of water vapor from exhaled breath yield biomarker levels at or near the detection limits of immunoassays contributing to problems with reproducibility and validity of biomarker measurements. In this study, we compare the collection efficiency of two aerosol-to-liquid sampling devices to a filter-based collection method for recovery of dilute laboratory generated aerosols of human cytokines so as to identify potential alternatives to exhaled breath condensate collection. Methodology/Principal Findings Two aerosol-to-liquid sampling devices, the SKC® Biosampler and Omni 3000™, as well as Teflon® filters were used to collect aerosols of human cytokines generated using a HEART nebulizer and single-pass aerosol chamber setup in order to compare the collection efficiencies of these sampling methods. Additionally, methods for the use of Teflon® filters to collect and measure cytokines recovered from aerosols were developed and evaluated through use of a high-sensitivity multiplex immunoassay. Our results show successful collection of cytokines from pg/m3 aerosol concentrations using Teflon® filters and measurement of cytokine levels in the sub-picogram/mL concentration range using a multiplex immunoassay with sampling times less than 30 minutes. Significant degradation of cytokines was observed due to storage of cytokines in concentrated filter extract solutions as compared to storage of dry filters. Conclusions Use of filter collection methods resulted in significantly higher efficiency of collection than the two aerosol-to-liquid samplers evaluated in our study. The results of this study provide the foundation for a potential new technique to evaluate biomarkers of inflammation in exhaled breath samples. PMID:22574123

  20. Radiochemical sampling and analysis of shallow ground water and sediment at the BOMARC Missile Facility, east-central New Jersey, 1999-2000

    USGS Publications Warehouse

    Szabo, Zoltan; Zapecza, Otto S.; Oden, Jeannette H.; Rice, Donald E.

    2005-01-01

    A field sampling experiment was designed using low-flow purging with a portable pump and sample-collection equipment for the collection of water and sediment samples from observation wells screened in the Kirkwood-Cohansey aquifer system to determine radionuclide or trace-element concentrations for various size fractions. Selected chemical and physical characteristics were determined for water samples from observation wells that had not been purged for years. The sampling was designed to define any particulate, colloidal, and solution-phase associations of radionuclides or trace elements in ground water by means of filtration and ultrafiltration techniques. Turbidity was monitored and allowed to stabilize before samples were collected by means of the low-flow purging technique rather than by the traditional method of purging a fixed volume of water at high-flow rates from the observation well. A minimum of four water samples was collected from each observation well. The samples of water from each well were collected in the following sequence. (1) A raw unfiltered sample was collected within the first minutes of pumping. (2) A raw unfiltered sample was collected after at least three casing volumes of water were removed and turbidity stabilized. (3) A sample was collected after the water was filtered with a 0.45-micron filter. (4) A sample was collected after the water passed through a 0.45-micron filter and a 0.003-micron tangential-flow ultrafilter in sequence. In some cases, a fifth sample was collected after the water passed through a 0.45-micron filter and a 0.05-micron filter in sequence to test for colloids of 0.003 microns to 0.05 microns in size. The samples were analyzed for the concentration of manmade radionuclides plutonium-238 and -239 plus -240, and americium-241. The samples also were analyzed for concentrations of uranium-234, -235, and -238 to determine whether uranium-234 isotope enrichment (resulting from industrial processing) is present. A subset of samples was analyzed for concentrations of thorium-232, -230, and -228 to determine if thorium-228 isotope enrichment, also likely to result from industrial processing, is present. Concentrations of plutonium isotopes and americium-241 in the water samples were less than 0.1 picocurie per liter, the laboratory reporting level for these manmade radionuclides, with the exception of one americium-241 concentration from a filtered sample. A sequential split sample from the same well did not contain a detectable concentration of americium-241, however. Other filtered and unfiltered samples of water from the same well did not contain quantities of americium-241 nearly as high as 0.1 pCi/L. Therefore, the presence of americium-241 in a quantifiable concentration in water samples from this well could not be confirmed. Neither plutonium nor americium was detected in samples of settled sediment collected from the bottom of the wells. Concentrations of uranium isotopes (maximum of 0.05 and 0.08 picocuries per liter of uranium-238 and uranium-234, respectively) were measurable in unfiltered samples of turbid water from one well and in the settled bottom sediment from 6 wells (maximum concentrations of 0.25 and 0.20 picocuries per gram of uranium-238 and uranium-234, respectively). The uranium-234/uranium-238 isotopic ratio was near 1:1, which indicates natural uranium. The analytical results, therefore, indicate that no manmade radionuclide contamination is present in any of the well-bottom sediments, or unfiltered or filtered water samples from any of the sampled wells. No evidence of manmade radionuclide contamination was observed in the aquifer as settled or suspended particulates, colloids, or in the dissolved phase.

  1. Efficiency of two-way weirs and prepositioned electrofishing for sampling potamodromous fish migrations

    USGS Publications Warehouse

    Favrot, Scott D.; Kwak, Thomas J.

    2016-01-01

    Potamodromy (i.e., migration entirely in freshwater) is a common life history strategy of North American lotic fishes, and efficient sampling methods for potamodromous fishes are needed to formulate conservation and management decisions. Many potamodromous fishes inhabit medium-sized rivers and are mobile during spawning migrations, which complicates sampling with conventional gears (e.g., nets and electrofishing). We compared the efficiency of a passive migration technique (resistance board weirs) and an active technique (prepositioned areal electrofishers; [PAEs]) for sampling migrating potamodromous fishes in Valley River, a southern Appalachian Mountain river, from March through July 2006 and 2007. A total of 35 fish species from 10 families were collected, 32 species by PAE and 19 species by weir. Species richness and diversity were higher for PAE catch, and species dominance (i.e., proportion of assemblage composed of the three most abundant species) was higher for weir catch. Prepositioned areal electrofisher catch by number was considerably higher than weir catch, but biomass was lower for PAE catch. Weir catch decreased following the spawning migration, while PAEs continued to collect fish. Sampling bias associated with water velocity was detected for PAEs, but not weirs, and neither gear demonstrated depth bias in wadeable reaches. Mean fish mortality from PAEs was five times greater than that from weirs. Catch efficiency and composition comparisons indicated that weirs were effective at documenting migration chronology, sampling nocturnal migration, and yielding samples unbiased by water velocity or habitat, with low mortality. Prepositioned areal electrofishers are an appropriate sampling technique for seasonal fish occupancy objectives, while weirs are more suitable for quantitatively describing spawning migrations. Our comparative results may guide fisheries scientists in selecting an appropriate sampling gear and regime for research, monitoring, conservation, and management of potamodromous fishes.

  2. Final Reports of the Stardust ISPE: Seven Probable Interstellar Dust Particles

    NASA Technical Reports Server (NTRS)

    Allen, Carlton; Sans Tresseras, Juan-Angel; Westphal, Andrew J.; Stroud, Rhonda M.; Bechtel, Hans A.; Brenker, Frank E.; Butterworth, Anna L.; Flynn, George J.; Frank, David R.; Gainsforth, Zack; hide

    2014-01-01

    The Stardust spacecraft carried the first spaceborne collector specifically designed to capture and return a sample of contemporary interstellar dust to terrestrial laboratories for analysis [1]. The collector was exposed to the interstellar dust stream in two periods in 2000 and 2002 with a total exposure of approximately 1.8 10(exp 6) square meters sec. Approximately 85% of the collector consisted of aerogel, and the remainder consisted of Al foils. The Stardust Interstellar Preliminary Examination (ISPE) was a consortiumbased effort to characterize the collection in sufficient detail to enable future investigators to make informed sample requests. Among the questions to be answered were these: How many impacts are consistent in their characteristics with interstellar dust, with interplanetary dust, and with secondary ejecta from impacts on the spacecraft? Are the materials amorphous or crystalline? Are organics detectable? An additional goal of the ISPE was to develop or refine the techniques for preparation, analysis, and curation of these tiny samples, expected to be approximately 1 picogram or smaller, roughly three orders of magnitude smaller in mass than the samples in other small particle collections in NASA's collections - the cometary samples returned by Stardust, and the collection of Interplanetary Dust Particles collected in the stratosphere.

  3. A comparison of two gears for quantifying abundance of lotic-dwelling crayfish

    USGS Publications Warehouse

    Williams, Kristi; Brewer, Shannon K.; Ellersieck, Mark R.

    2014-01-01

    Crayfish (saddlebacked crayfish, Orconectes medius) catch was compared using a kick seine applied two different ways with a 1-m2 quadrat sampler (with known efficiency and bias in riffles) from three small streams in the Missouri Ozarks. Triplicate samples (one of each technique) were taken from two creeks and one headwater stream (n=69 sites) over a two-year period. General linear mixed models showed the number of crayfish collected using the quadrat sampler was greater than the number collected using either of the two seine techniques. However, there was no significant interaction with gear suggesting year, stream size, and channel unit type did not relate to different catches of crayfish by gear type. Variation in catch among gears was similar, as was the proportion of young-of-year individuals across samples taken with different gears or techniques. Negative binomial linear regression provided the appropriate relation between the gears which allows correction factors to be applied, if necessary, to relate catches by the kick seine to those of the quadrat sampler. The kick seine appears to be a reasonable substitute to the quadrat sampler in these shallow streams, with the advantage of ease of use and shorter time required per sample.

  4. Soil gas screening for chlorinated solvents at three contaminated karst sites in Tennessee

    USGS Publications Warehouse

    Wolfe, W.J.; Williams, S.D.

    2002-01-01

    Soil gas was sampled using active sampling techniques and passive collectors at three sites in Tennessee to evaluate the effectiveness of these techniques for locating chlorinated solvent sources and flowpaths in karst aquifers. Actively collected soil gas samples were analyzed in the field with a portable gas chromatograph, and the passive soil gas collectors were analyzed in the lab with gas chromatography/mass spectrometry. Results of the sampling indicate that the effectiveness of both techniques is highly dependent on the distribution of the contaminants in the subsurface, the geomorphic and hydrogeologic characteristics of the site, and, in one case, on seasonal conditions. Both active and passive techniques identified areas of elevated subsurface chlorinated solvent concentrations at a landfill site where contamination remains concentrated in the regolith. Neither technique detected chlorinated solvents known to be moving in the bedrock at a manufacturing site characterized by thick regolith and an absence of surficial karst features. Passive soil gas sampling had varied success detecting flowpaths for chloroform in the bedrock at a train derailment site characterized by shallow regolith and abundant surficial karst features. At the train derailment site, delineation of the contaminant flowpath through passive soil gas sampling was stronger and more detailed under Winter conditions than summer.

  5. 2013 Consequence Management Advisory Team (CMAT) Annual Report

    EPA Pesticide Factsheets

    Chemical, Biological, Radiological and Nuclear CMAT reviews use of data tools such as Airborne Spectral Photometric Environmental Collection Technology, new sampling and decontamination techniques, new response technologies, and improvement potential.

  6. Pulsating potentiometric titration technique for assay of dissolved oxygen in water at trace level.

    PubMed

    Sahoo, P; Ananthanarayanan, R; Malathi, N; Rajiniganth, M P; Murali, N; Swaminathan, P

    2010-06-11

    A simple but high performance potentiometric titration technique using pulsating sensors has been developed for assay of dissolved oxygen (DO) in water samples down to 10.0 microg L(-1) levels. The technique involves Winkler titration chemistry, commonly used for determination of dissolved oxygen in water at mg L(-1) levels, with modification in methodology for accurate detection of end point even at 10.0 microg L(-1) levels DO present in the sample. An indigenously built sampling cum pretreatment vessel has been deployed for collection and chemical fixing of dissolved oxygen in water samples from flowing water line without exposure to air. A potentiometric titration facility using pulsating sensors developed in-house is used to carry out titration. The power of the titration technique has been realised in estimation of very dilute solution of iodine equivalent to 10 microg L(-1) O(2). Finally, several water samples containing dissolved oxygen from mg L(-1) to microg L(-1) levels were successfully analysed with excellent reproducibility using this new technique. The precision in measurement of DO in water at 10 microg L(-1) O(2) level is 0.14 (n=5), RSD: 1.4%. Probably for the first time a potentiometric titration technique has been successfully deployed for assay of dissolved oxygen in water samples at 10 microg L(-1) levels. Copyright 2010 Elsevier B.V. All rights reserved.

  7. The transferability of diatoms to clothing and the methods appropriate for their collection and analysis in forensic geoscience.

    PubMed

    Scott, Kirstie R; Morgan, Ruth M; Jones, Vivienne J; Cameron, Nigel G

    2014-08-01

    Forensic geoscience is concerned with the analysis of geological materials in order to compare and exclude environmental samples from a common source, or to identify an unknown provenance in a criminal investigation. Diatom analysis is currently an underused technique within the forensic geoscience approach, which has the potential to provide an independent ecological assessment of trace evidence. This study presents empirical data to provide a preliminary evidence base in order to be able to understand the nature of diatom transfers to items of clothing, and the collection of transferred diatom trace evidence from a range of environments under experimental conditions. Three diatom extraction methods were tested on clothing that had been in contact with soil and water sites: rinsing in water (RW), rinsing in ethanol (RE), and submersion in H2O2 solution (H). Scanning electron microscopy (S.E.M.) analysis was undertaken in order to examine the degree of diatom retention on treated clothing samples. The total diatom yield and species richness data was recorded from each experimental sample in order to compare the efficacy of each method in collecting a representative sample for analysis. Similarity was explored using correspondence analysis. The results highlight the efficiency of H2O2 submersion in consistently extracting high diatom counts with representative species from clothing exposed to both aquatic and terrestrial sites. This is corroborated by S.E.M. analysis. This paper provides an important empirical evidence base for both establishing that diatoms do indeed transfer to clothing under forensic conditions in a range of environments, and in identifying that H2O2 extraction is the most efficient technique for the optimal collection of comparative samples. There is therefore potentially great value in collecting and analysing diatom components of geoforensic samples in order to aid in forensic investigation. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  8. Use of on-site high performance liquid chromatography to evaluate the magnitude and extent of organic contaminants in aquifers

    USGS Publications Warehouse

    Goerlitz, D.F.; Franks, B.J.

    1989-01-01

    Appraisal of ground water contaminated by organic substances raises problems of difficult sample collection and timely chemical analysis. High-performance liquid chromatography was evaluated for on-site determination of specific organic contaminants in ground water samples and was used at three study sites. Organic solutes were determined directly in water samples, with little or no preparation, and usually in less than an hour after collection. This information improved sampling efficiency and was useful in screening for subsequent laboratory analysis. On two occasions, on-site analysis revealed that samples were undergoing rapid change, with major solutes being upgraded and alteration products being formed. In addition to sample stability, this technique proved valuable for monitoring other sampling factors such as compositional changes with respect to pumping, filtration, and cross contamination. -Authors

  9. Quality of the antimalarial medicine artemether - lumefantrine in eight cities of the Democratic Republic of the Congo.

    PubMed

    Mufusama, Jean-Pierre; Ioset, Karine Ndjoko; Feineis, Doris; Hoellein, Ludwig; Holzgrabe, Ulrike; Bringmann, Gerhard

    2018-06-12

    In the context of post-marketing surveillance supporting public-health authorities to take evidence-based decisions to fight the spread of poor-quality medicines, the quality of antimalarial artemether-lumefantrine (AL) medicines was assessed in the Democratic Republic of the Congo (DRC). A total of 150 samples of AL containing products was collected from private pharmaceutical outlets in eight main cities: Goma, Kikwit, Kinshasa, Kisangani, Lubumbashi, Matadi, Mbandaka, and Mbuji-Mayi. All drug samples were successively analyzed by visual inspection, thin-layer chromatography (TLC), and high-performance liquid chromatography (HPLC) following The International Pharmacopoeia. Out of the 150 collected drug samples, three (2%) failed the visual inspection as they had shelf lives different from those of other samples with the same brand name. Four samples (2.7%) did not pass the TLC test as they contained only one or even none of the two declared active pharmaceutical ingredients (APIs). HPLC assays showed that 46 (30.7%) samples had artemether contents below 90% and 17 (11.3%) above 110% of the content claimed on the label. For lumefantrine, 32 (21.7%) samples had contents below 90%, and eight (5.3%) had contents above 110%. This survey in DRC gives evidence that poor-quality antimalarial medicines are widely present. Based on three detection techniques, the study shows the necessity to equip developing countries with modern techniques such as HPLC, which, if combined with affordable techniques like TLC, could provide a pertinent analytical strategy to combat drug counterfeiting and poor manufacturing. This article is protected by copyright. All rights reserved.

  10. Does Nosema ceranae Wipe Out Nosema apis in Turkey?

    PubMed

    Ivgin Tunca, Rahşan; Oskay, Devrim; Gosterit, Ayhan; Tekin, Olgay Kaan

    2016-01-01

    The aim of this study was to determine the prevalence of the Nosema ceranae and Nosema apis among apiaries using both spore counts and multiplex PCR and the replacement of N. apis by N. ceranae in some regions of Turkey. A hundred honey bee samples were collected from 99 apiaries in 11 different locations in 2011-2012 in Turkey. Nosema infection degree from collected samples was determined using light microscope and molecular detection of Nosema spp. ( N. ceranae and N. apis ) was performed using specific primers by multiplex PCR. N. ceranae was only found spores in sampling areas using molecular diagnosis. N. apis was not detected in whole sampling areas using both techniques. There are no Nosema spores detected in Konya one location using two techniques. The nucleotide sequences from amplification products of the Nosema infested honeybee samples were (98%) identical with the sequence of N. ceranae for many countries deposited in the GenBank database in this study. The present study illustrated that N. ceranae is the only spores for sampled areas in 2011-2012. The study could also indicate that N. ceranae has been replaced instead of N . apis in Turkey. In addition, the prevalence of N. ceranae and two microsporodia spores effects on honey bee colonies in Turkey were needed to determine with intensive sampling, periodically.

  11. Gas dispersion concentration of trace inorganic contaminants from fuel gas and analysis using head-column field-amplified sample stacking capillary electrophoresis.

    PubMed

    Yang, Jianmin; Li, Hai-Fang; Li, Meilan; Lin, Jin-Ming

    2012-08-21

    The presence of inorganic elements in fuel gas generally accelerates the corrosion and depletion of materials used in the fuel gas industry, and even leads to serious accidents. For identification of existing trace inorganic contaminants in fuel gas in a portable way, a highly efficient gas-liquid sampling collection system based on gas dispersion concentration is introduced in this work. Using the constructed dual path gas-liquid collection setup, inorganic cations and anions were simultaneously collected from real liquefied petroleum gas (LPG) and analyzed by capillary electrophoresis (CE) with indirect UV absorbance detection. The head-column field-amplified sample stacking technique was applied to improve the detection limits to 2-25 ng mL(-1). The developed collection and analytical methods have successfully determined existing inorganic contaminants in a real LPG sample in the range of 4.59-138.69 μg m(-3). The recoveries of cations and anions with spiked LPG samples were between 83.98 and 105.63%, and the relative standard deviations (RSDs) were less than 7.19%.

  12. Techniques for Nonterminal Blood Sampling in Black-Tailed Prairie Dogs (Cynomys ludovicianus).

    PubMed

    Head, Valerie; Eshar, David; Nau, Melissa R

    2017-03-01

    Black-tailed prairie dogs (Cynomys ludovicianus) are used as an animal model for research on gallbladder stones and several infectious diseases. A comprehensive, instructive resource regarding the appropriate techniques for venipuncture and collection of nonterminal blood samples in this species has not yet been published. Blood samples (1 mL or larger) were readily obtained from the jugular vein, femoral vein, or cranial vena cava, whereas peripheral sites, such as the cephalic vein, saphenous vein, and tarsal vein, mainly were useful for obtaining smaller volumes. The detailed and illustrated information presented here can aid clinicians and researchers in performing venipuncture, anesthesia, and handling of this species.

  13. Salivary flow and alpha-amylase: collection technique, duration, and oral fluid type.

    PubMed

    Beltzer, Emilie K; Fortunato, Christine K; Guaderrama, Melissa M; Peckins, Melissa K; Garramone, Bianca M; Granger, Douglas A

    2010-09-01

    There has been renewed interest in salivary alpha-amylase (sAA), a surrogate marker of autonomic/sympathetic activity, in biosocial research on stress vulnerability, reactivity, and recovery. This study explored the impact of saliva flow rate on sAA measurement by examining the influence of (1) the technique used to collect oral fluid-synthetic swab, cotton pledget, hydrocellulose microsponge, or passive drool; (2) collection point duration--the length of time the technique is employed (1-5min); and (3) oral fluid type--whole unstimulated saliva (not absorbed by any material) or oral fluid sampled from areas near the parotid, submandibular, or sublingual salivary glands. sAA activity (U/mL) was the highest in oral fluid collected from the parotid and submandibular gland areas. The volume (mL) of oral fluid collected increased, and the activity of sAA (U/mL) decreased, as collection point duration lengthened. The magnitude of these effects varied according to collection technique and oral fluid type. Across all conditions, there were positive correlations (range .70-.88) between sAA activity (U/mL) and sAA output (U/min). Management of these potential sources of measurement error will be essential to ensuring the success of future research on the correlates and concomitants of sAA activity, stress-related reactivity and recovery, and diurnal variation. Copyright 2010 Elsevier Inc. All rights reserved.

  14. Cooperative Learning as a Correction and Grammar Revision Technique: Communicative Exchanges, Self-Correction Rates and Scores

    ERIC Educational Resources Information Center

    Servetti, Sara

    2010-01-01

    This paper focuses on cooperative learning (CL) used as a correction and grammar revision technique and considers the data collected in six Italian parallel classes, three of which (sample classes) corrected mistakes and revised grammar through cooperative learning, while the other three (control classes) in a traditional way. All the classes…

  15. Microchemical Analysis Of Space Operation Debris

    NASA Technical Reports Server (NTRS)

    Cummings, Virginia J.; Kim, Hae Soo

    1995-01-01

    Report discusses techniques used in analyzing debris relative to space shuttle operations. Debris collected from space shuttle, expendable launch vehicles, payloads carried by space shuttle, and payloads carried by expendable launch vehicles. Optical microscopy, scanning electron microscopy with energy-dispersive spectrometry, analytical electron microscopy with wavelength-dispersive spectrometry, and X-ray diffraction chosen as techniques used in examining samples of debris.

  16. Synchronous Teaching Techniques from the Perspective and Observation of Virtual High School Teachers: An Investigative Study

    ERIC Educational Resources Information Center

    O'Brien, Amy; Fuller, Richard

    2018-01-01

    This article describes how there are specific tools and techniques used by teachers in synchronous-live-virtual classroom environments. Those items were investigated in this article. Data was collected from semi-structured, one-on-one interviews conducted with a purposeful sample of twelve identified "highly-qualified" teachers at a…

  17. Infectious Cryptosporidium parvum oocysts in final reclaimed effluent

    USGS Publications Warehouse

    Gennaccaro, A.L.; McLaughlin, M.R.; Quintero-Betancourt, W.; Huffman, D.E.; Rose, J.B.

    2003-01-01

    Water samples collected throughout several reclamation facilities were analyzed for the presence of infectious Cryptosporidium parvum by the focus detection method-most-probable-number cell culture technique. Results revealed the presence of infectious C. parvum oocysts in 40% of the final disinfected effluent samples. Sampled effluent contained on average seven infectious oocysts per 100 liters. Thus, reclaimed water is not pathogen free but contains infectious C. parvum.

  18. Sampling methods for terrestrial amphibians and reptiles.

    Treesearch

    Paul Stephen Corn; R. Bruce Bury

    1990-01-01

    Methods described for sampling amphibians and reptiles in Douglas-fir forests in the Pacific Northwest include pitfall trapping, time-constrained collecting, and surveys of coarse woody debris. The herpetofauna of this region differ in breeding and nonbreeding habitats and vagility, so that no single technique is sufficient for a community study. A combination of...

  19. An Analysis of Job Satisfaction Among Public, College or University, and Special Librarians.

    ERIC Educational Resources Information Center

    Miniter, John J.

    Usable data relating to six elements of job satisfaction: work, supervision, people, pay, promotion, and total satisfaction, were collected from 190 of a total sample of 310 librarians, chosen by stratified random sampling techniques from library association membership lists. The librarians, both male and female, represented three types of…

  20. Chemiluminescence: Measuring methods. (Latest citations from the NTIS bibliographic database). Published Search

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The bibliography contains citations concerning chemiluminescence assays. The citations include sample system design, sample collection, measurement techniques, and sensitivity of the instrumentation. Applications in high altitude air pollution studies are emphasized. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  1. A Study of Occupational Stress and Organizational Climate of Higher Secondary Teachers

    ERIC Educational Resources Information Center

    Benedicta, A. Sneha

    2014-01-01

    This study mainly aims to describe the occupational stress and organizational climate of higher secondary teachers with regard to gender, locality, family type, experience and type of management. Simple random sampling technique was adopted for the selection of sample. The data is collected from 200 higher secondary teachers from government and…

  2. Correcting for Microbial Blooms in Fecal Samples during Room-Temperature Shipping.

    PubMed

    Amir, Amnon; McDonald, Daniel; Navas-Molina, Jose A; Debelius, Justine; Morton, James T; Hyde, Embriette; Robbins-Pianka, Adam; Knight, Rob

    2017-01-01

    The use of sterile swabs is a convenient and common way to collect microbiome samples, and many studies have shown that the effects of room-temperature storage are smaller than physiologically relevant differences between subjects. However, several bacterial taxa, notably members of the class Gammaproteobacteria , grow at room temperature, sometimes confusing microbiome results, particularly when stability is assumed. Although comparative benchmarking has shown that several preservation methods, including the use of 95% ethanol, fecal occult blood test (FOBT) and FTA cards, and Omnigene-GUT kits, reduce changes in taxon abundance during room-temperature storage, these techniques all have drawbacks and cannot be applied retrospectively to samples that have already been collected. Here we performed a meta-analysis using several different microbiome sample storage condition studies, showing consistent trends in which specific bacteria grew (i.e., "bloomed") at room temperature, and introduce a procedure for removing the sequences that most distort analyses. In contrast to similarity-based clustering using operational taxonomic units (OTUs), we use a new technique called "Deblur" to identify the exact sequences corresponding to blooming taxa, greatly reducing false positives and also dramatically decreasing runtime. We show that applying this technique to samples collected for the American Gut Project (AGP), for which participants simply mail samples back without the use of ice packs or other preservatives, yields results consistent with published microbiome studies performed with frozen or otherwise preserved samples. IMPORTANCE In many microbiome studies, the necessity to store samples at room temperature (i.e., remote fieldwork) and the ability to ship samples without hazardous materials that require special handling training, such as ethanol (i.e., citizen science efforts), is paramount. However, although room-temperature storage for a few days has been shown not to obscure physiologically relevant microbiome differences between comparison groups, there are still changes in specific bacterial taxa, notably, in members of the class Gammaproteobacteria , that can make microbiome profiles difficult to interpret. Here we identify the most problematic taxa and show that removing sequences from just a few fast-growing taxa is sufficient to correct microbiome profiles.

  3. Correcting for Microbial Blooms in Fecal Samples during Room-Temperature Shipping

    PubMed Central

    Amir, Amnon; McDonald, Daniel; Navas-Molina, Jose A.; Debelius, Justine; Morton, James T.; Hyde, Embriette; Robbins-Pianka, Adam

    2017-01-01

    ABSTRACT The use of sterile swabs is a convenient and common way to collect microbiome samples, and many studies have shown that the effects of room-temperature storage are smaller than physiologically relevant differences between subjects. However, several bacterial taxa, notably members of the class Gammaproteobacteria, grow at room temperature, sometimes confusing microbiome results, particularly when stability is assumed. Although comparative benchmarking has shown that several preservation methods, including the use of 95% ethanol, fecal occult blood test (FOBT) and FTA cards, and Omnigene-GUT kits, reduce changes in taxon abundance during room-temperature storage, these techniques all have drawbacks and cannot be applied retrospectively to samples that have already been collected. Here we performed a meta-analysis using several different microbiome sample storage condition studies, showing consistent trends in which specific bacteria grew (i.e., “bloomed”) at room temperature, and introduce a procedure for removing the sequences that most distort analyses. In contrast to similarity-based clustering using operational taxonomic units (OTUs), we use a new technique called “Deblur” to identify the exact sequences corresponding to blooming taxa, greatly reducing false positives and also dramatically decreasing runtime. We show that applying this technique to samples collected for the American Gut Project (AGP), for which participants simply mail samples back without the use of ice packs or other preservatives, yields results consistent with published microbiome studies performed with frozen or otherwise preserved samples. IMPORTANCE In many microbiome studies, the necessity to store samples at room temperature (i.e., remote fieldwork) and the ability to ship samples without hazardous materials that require special handling training, such as ethanol (i.e., citizen science efforts), is paramount. However, although room-temperature storage for a few days has been shown not to obscure physiologically relevant microbiome differences between comparison groups, there are still changes in specific bacterial taxa, notably, in members of the class Gammaproteobacteria, that can make microbiome profiles difficult to interpret. Here we identify the most problematic taxa and show that removing sequences from just a few fast-growing taxa is sufficient to correct microbiome profiles. PMID:28289733

  4. Reported credibility techniques in higher education evaluation studies that use qualitative methods: A research synthesis.

    PubMed

    Liao, Hongjing; Hitchcock, John

    2018-06-01

    This synthesis study examined the reported use of credibility techniques in higher education evaluation articles that use qualitative methods. The sample included 118 articles published in six leading higher education evaluation journals from 2003 to 2012. Mixed methods approaches were used to identify key credibility techniques reported across the articles, document the frequency of these techniques, and describe their use and properties. Two broad sets of techniques were of interest: primary design techniques (i.e., basic), such as sampling/participant recruitment strategies, data collection methods, analytic details, and additional qualitative credibility techniques (e.g., member checking, negative case analyses, peer debriefing). The majority of evaluation articles reported use of primary techniques although there was wide variation in the amount of supporting detail; most of the articles did not describe the use of additional credibility techniques. This suggests that editors of evaluation journals should encourage the reporting of qualitative design details and authors should develop strategies yielding fuller methodological description. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Enhanced Conformational Sampling Using Replica Exchange with Collective-Variable Tempering

    PubMed Central

    2015-01-01

    The computational study of conformational transitions in RNA and proteins with atomistic molecular dynamics often requires suitable enhanced sampling techniques. We here introduce a novel method where concurrent metadynamics are integrated in a Hamiltonian replica-exchange scheme. The ladder of replicas is built with different strengths of the bias potential exploiting the tunability of well-tempered metadynamics. Using this method, free-energy barriers of individual collective variables are significantly reduced compared with simple force-field scaling. The introduced methodology is flexible and allows adaptive bias potentials to be self-consistently constructed for a large number of simple collective variables, such as distances and dihedral angles. The method is tested on alanine dipeptide and applied to the difficult problem of conformational sampling in a tetranucleotide. PMID:25838811

  6. Operational Toxicology Research

    DTIC Science & Technology

    2006-08-01

    Activity Relationships CQSARs) assessments of Air Force chemicals. Assay samples Completed collected for biochemical and molecular endpoints and...techniques for perchlorate in water, groundwater, soil and biological matrices such as blood, urine , milk. thyroid and other tissues required for...in vivo laboratory animal experiments with a l710D70ll Toxicological Response in Urine Using variety of known target organ toxicants, collect urine

  7. Variability of 137Cs inventory at a reference site in west-central Iran.

    PubMed

    Bazshoushtari, Nasim; Ayoubi, Shamsollah; Abdi, Mohammad Reza; Mohammadi, Mohammad

    2016-12-01

    137 Cs technique has been widely used for the evaluation rates and patterns of soil erosion and deposition. This technique requires an accurate estimate of the values of 137 Cs inventory at the reference site. This study was conducted to evaluate the variability of the inventory of 137 Cs regarding to the sampling program including sample size, distance and sampling method at a reference site located in vicinity of Fereydan district in Isfahan province, west-central Iran. Two 3 × 8 grids were established comprising large grid (35 m length and 8 m width), and small grid (24 m length and 6 m width). At each grid intersection two soil samples were collected from 0 to 15 cm and 15-30 cm depths, totally 96 soil samples from 48 sampling points. Coefficients of variation for 137 Cs inventory in the soil samples was relatively low (CV = 15%), and the sampling distance and methods used did not significantly affect the 137 Cs inventories across the studied reference site. To obtain a satisfactory estimate of the mean 137 Cs activity in the reference sites, particularly those located in the semiarid regions, it is recommended to collect at least four samples along in a grid pattern 3 m apart. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Study of sampling systems for comets and Mars

    NASA Technical Reports Server (NTRS)

    Amundsen, R. J.; Clark, B. C.

    1987-01-01

    Several aspects of the techniques that can be applied to acquisition and preservation of samples from Mars and a cometary nucleus were examined. Scientific approaches to sampling, grounded in proven engineering methods are the key to achieving the maximum science value from the sample return mission. If development of these approaches for collecting and preserving does not preceed mission definition, it is likely that only suboptimal techniques will be available because of the constraints of formal schedule timelines and the normal pressure to select only the most conservative and least sophisticated approaches when development has lagged the mission milestones. With a reasonable investment now, before the final mission definition, the sampling approach can become highly developed, ready for implementation, and mature enough to help set the requirements for the mission hardware and its performance.

  9. Nuts and Bolts - Techniques for Genesis Sample Curation

    NASA Technical Reports Server (NTRS)

    Burkett, Patti J.; Rodriquez, M. C.; Allton, J. H.

    2011-01-01

    The Genesis curation staff at NASA Johnson Space Center provides samples and data for analysis to the scientific community, following allocation approval by the Genesis Oversight Committee, a sub-committee of CAPTEM (Curation Analysis Planning Team for Extraterrestrial Materials). We are often asked by investigators within the scientific community how we choose samples to best fit the requirements of the request. Here we will demonstrate our techniques for characterizing samples and satisfying allocation requests. Even with a systematic approach, every allocation is unique. We are also providing updated status of the cataloging and characterization of solar wind collectors as of January 2011. The collection consists of 3721 inventoried samples consisting of a single fragment, or multiple fragments containerized or pressed between post-it notes, jars or vials of various sizes.

  10. Dosimeter for monitoring vapors and aerosols of organic compounds

    DOEpatents

    Vo-Dinh, T.

    1987-07-14

    A dosimeter is provided for collecting and detecting vapors and aerosols of organic compounds. The dosimeter comprises a lightweight, passive device that can be conveniently worn by a person as a badge or placed at a stationary location. The dosimeter includes a sample collector comprising a porous web treated with a chemical for inducing molecular displacement and enhancing phosphorescence. Compounds are collected onto the web by molecular diffusion. The web also serves as the sample medium for detecting the compounds by a room temperature phosphorescence technique. 7 figs.

  11. Protein blotting protocol for beginners.

    PubMed

    Petrasovits, Lars A

    2014-01-01

    The transfer and immobilization of biological macromolecules onto solid nitrocellulose or nylon (polyvinylidene difluoride (PVDF)) membranes subsequently followed by specific detection is referred to as blotting. DNA blots are called Southerns after the inventor of the technique, Edwin Southern. By analogy, RNA blots are referred to as northerns and protein blots as westerns (Burnette, Anal Biochem 112:195-203, 1981). With few exceptions, western blotting involves five steps, namely, sample collection, preparation, separation, immobilization, and detection. In this chapter, protocols for the entire process from sample collection to detection are described.

  12. Evaluation of a novel dried blood spot collection device (HemaSpot™) to test blood samples collected from dogs for antibodies to Leishmania infantum.

    PubMed

    Rosypal, Alexa C; Pick, Leanne D; Hernandez, Jaime O Esquivel; Lindsay, David S

    2014-09-15

    Collection of blood samples from veterinary and wildlife patients is often challenging because the samples have to be collected on farm or in the wild under various environmental conditions. This poses many technical problems associated with venipuncture materials, their safe use and disposal, transportation and processing of collected samples. Dried blood spot (DBS) sample collection techniques offer a simple and practical alternative to traditional blood collection methods to obtain blood samples from animals for parasite antibody evaluation. The DBS collection devices are compact, simple to use, and are particularly useful for large number of samples. Additionally, DBS samples take up less space and they are easier to transport than traditional venipuncture-collected blood samples. Visceral leishmaniasis (VL) is a potentially fatal parasitic disease of dogs and humans and it is frequently diagnosed by antibody tests. Immunochromatographic tests (ICT) for antibodies to Leishmania infantum are commercially available for dogs and they produce qualitative results in minutes. Measurement of canine antibodies to L. infantum with the ICT using traditional venipuncture has been validated previously, but the use of DBS samples has not been evaluated using this method. The purpose of the present study was to determine the ability of DBS samples to detect antibodies to L. infantum in dogs using a commercial ICT assay. One hundred plasma samples from dogs experimentally infected with the LIVT-1 strain of L. infantum were collected by venipuncture and frozen. Individual samples were thawed, and then 80 μl plasma (2 drops) was aliquotted onto the 8-spoked disk pad on individual DBS sample collection devices (HemaSpot™, Spot-On Sciences, Austin, TX), dried, and stored in the dark at room temperature. After one month and six months, respectively, 2 spokes of the 8 spokes of the disk pad of each DBS sample were removed and eluted in 200 μl PBS. The eluate was used to test for antibodies in the ICT and compared to ICT results using thawed plasma (same initial source). Sensitivity and specificity of the ICT using DBS were determined by using ICT results from traditional blood collection samples for comparison. After 1 month, DBS samples showed 100% sensitivity and specificity when compared to ICT results on thawed plasma samples collected by traditional venipuncture. After six months storage at room temperature, DBS samples demonstrated 79% sensitivity and 100% specificity compared to traditional blood collection. Results from this study indicate that dried blood spot collection may be a useful tool for screening dogs for antibodies to L. infantum with the ICT assay. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Bridging the gap between sample collection and laboratory analysis: using dried blood spots to identify human exposure to chemical agents

    NASA Astrophysics Data System (ADS)

    Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.

    2016-05-01

    Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.

  14. Efficiently sampling conformations and pathways using the concurrent adaptive sampling (CAS) algorithm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahn, Surl-Hee; Grate, Jay W.; Darve, Eric F.

    Molecular dynamics (MD) simulations are useful in obtaining thermodynamic and kinetic properties of bio-molecules but are limited by the timescale barrier, i.e., we may be unable to efficiently obtain properties because we need to run microseconds or longer simulations using femtoseconds time steps. While there are several existing methods to overcome this timescale barrier and efficiently sample thermodynamic and/or kinetic properties, problems remain in regard to being able to sample un- known systems, deal with high-dimensional space of collective variables, and focus the computational effort on slow timescales. Hence, a new sampling method, called the “Concurrent Adaptive Sampling (CAS) algorithm,”more » has been developed to tackle these three issues and efficiently obtain conformations and pathways. The method is not constrained to use only one or two collective variables, unlike most reaction coordinate-dependent methods. Instead, it can use a large number of collective vari- ables and uses macrostates (a partition of the collective variable space) to enhance the sampling. The exploration is done by running a large number of short simula- tions, and a clustering technique is used to accelerate the sampling. In this paper, we introduce the new methodology and show results from two-dimensional models and bio-molecules, such as penta-alanine and triazine polymer« less

  15. Detection of equine herpesvirus in horses with idiopathic keratoconjunctivitis and comparison of three sampling techniques.

    PubMed

    Hollingsworth, Steven R; Pusterla, Nicola; Kass, Philip H; Good, Kathryn L; Brault, Stephanie A; Maggs, David J

    2015-09-01

    To determine the role of equine herpesvirus (EHV) in idiopathic keratoconjunctivitis in horses and to determine whether sample collection method affects detection of EHV DNA by quantitative polymerase chain reaction (qPCR). Twelve horses with idiopathic keratoconjunctivitis and six horses without signs of ophthalmic disease. Conjunctival swabs, corneal scrapings, and conjunctival biopsies were collected from 18 horses: 12 clinical cases with idiopathic keratoconjunctivitis and six euthanized controls. In horses with both eyes involved, the samples were taken from the eye judged to be more severely affected. Samples were tested with qPCR for EHV-1, EHV-2, EHV-4, and EHV-5 DNA. Quantity of EHV DNA and viral replicative activity were compared between the two populations and among the different sampling techniques; relative sensitivities of the sampling techniques were determined. Prevalence of EHV DNA as assessed by qPCR did not differ significantly between control horses and those with idiopathic keratoconjunctivitis. Sampling by conjunctival swab was more likely to yield viral DNA as assessed by qPCR than was conjunctival biopsy. EHV-1 and EHV-4 DNA were not detected in either normal or IKC-affected horses; EHV-2 DNA was detected in two of 12 affected horses but not in normal horses. EHV-5 DNA was commonly found in ophthalmically normal horses and horses with idiopathic keratoconjunctivitis. Because EHV-5 DNA was commonly found in control horses and in horses with idiopathic keratoconjunctivitis, qPCR was not useful for the etiological diagnosis of equine keratoconjunctivitis. Conjunctival swabs were significantly better at obtaining viral DNA samples than conjunctival biopsy in horses in which EHV-5 DNA was found. © 2015 American College of Veterinary Ophthalmologists.

  16. Identification of Species and Sources of Cryptosporidium Oocysts in Storm Waters with a Small-Subunit rRNA-Based Diagnostic and Genotyping Tool

    PubMed Central

    Xiao, Lihua; Alderisio, Kerri; Limor, Josef; Royer, Michael; Lal, Altaf A.

    2000-01-01

    The identification of Cryptosporidium oocysts in environmental samples is largely made by the use of an immunofluorescent assay. In this study, we have used a small-subunit rRNA-based PCR-restriction fragment length polymorphism technique to identify species and sources of Cryptosporidium oocysts present in 29 storm water samples collected from a stream in New York. A total of 12 genotypes were found in 27 positive samples; for 4 the species and probable origins were identified by sequence analysis, whereas the rest represent new genotypes from wildlife. Thus, this technique provides an alternative method for the detection and differentiation of Cryptosporidium parasites in environmental samples. PMID:11097935

  17. Micron Scale Mapping and Depth Profiling of Organic Compounds in Geologic Material: Femtosecond - Laser Desorption Laser Postionization - Mass Spectrometry (fs-LDPI-MS)

    NASA Astrophysics Data System (ADS)

    Pasterski, M. J.; Barry, G. E.; Hanley, L.; Kenig, F. P. H.

    2017-12-01

    One of the major challenges within the field of organic geochemistry is to determine whether an observed biomarker signature is indigenous (emplaced during sedimentation), non-indigenous (emplaced after sedimentation) or contaminant (incorporated during sampling, storage or analysis). The challenge of determining the mode of emplacement of an observed biomarker signature is accentuated in analyses of Precambrian samples, and may be an issue upon Mars sample return. Current geochemical techniques (e.g. gas chromatography-mass spectrometry, GC-MS, GC×GC-MS) can determine the composition and structure of the organic constituents of a sample. However, the preparatory steps necessary prior to GC-MS analysis (sample crushing, solvent extraction) make it impossible to determine the precise spatial distribution of organic molecules within rocks and sediments. Here, we will present data from the first set of micron (2-5 μm width × 8 μm depth) resolution MS-images of organic compounds in geologic material. Fs-LDPI-MS was utilized to create MS-images of organic compounds in four samples: (1) an Antarctic igneous dike used as a sample blank; (2) a 93 million year-old (Ma) burrowed carbonate collected near Pueblo, CO; (3) a 164 Ma organic rich mudstone collected in central England; and (4) a 2680 Ma metasediment collected in Timmins, ON, Canada. Prior to this study, all samples had been analyzed via GC-MS to determine the bulk hydrocarbon composition. For this study, thick sections (70-100 μm thick) were prepared in-house using custom-designed clean preparation techniques. Petrographic maps of the thick sections were created to highlight geologic features such as burrows (sample 2), particulate organic matter (sample 3) and hydrothermal veins (sample 4). Fs-LDPI-MS analysis was performed on the mapped thick sections. MS-images of targeted organic compounds were created, and the MS-images were overlain with the petrographic maps to determine the spatial distribution of the organic compounds relative to host rock features. We were able to use the spatial distribution of the targeted organic compounds to unambiguously characterize them as either indigenous, non-indigenous or contaminants. This technique is applicable to the analysis of both Precambrian samples and extraterrestrial material.

  18. Insights from two industrial hygiene pilot e-cigarette passive vaping studies.

    PubMed

    Maloney, John C; Thompson, Michael K; Oldham, Michael J; Stiff, Charles L; Lilly, Patrick D; Patskan, George J; Shafer, Kenneth H; Sarkar, Mohamadi A

    2016-01-01

    While several reports have been published using research methods of estimating exposure risk to e-cigarette vapors in nonusers, only two have directly measured indoor air concentrations from vaping using validated industrial hygiene sampling methodology. Our first study was designed to measure indoor air concentrations of nicotine, menthol, propylene glycol, glycerol, and total particulates during the use of multiple e-cigarettes in a well-characterized room over a period of time. Our second study was a repeat of the first study, and it also evaluated levels of formaldehyde. Measurements were collected using active sampling, near real-time and direct measurement techniques. Air sampling incorporated industrial hygiene sampling methodology using analytical methods established by the National Institute of Occupational Safety and Health and the Occupational Safety and Health Administration. Active samples were collected over a 12-hr period, for 4 days. Background measurements were taken in the same room the day before and the day after vaping. Panelists (n = 185 Study 1; n = 145 Study 2) used menthol and non-menthol MarkTen prototype e-cigarettes. Vaping sessions (six, 1-hr) included 3 prototypes, with total number of puffs ranging from 36-216 per session. Results of the active samples were below the limit of quantitation of the analytical methods. Near real-time data were below the lowest concentration on the established calibration curves. Data from this study indicate that the majority of chemical constituents sampled were below quantifiable levels. Formaldehyde was detected at consistent levels during all sampling periods. These two studies found that indoor vaping of MarkTen prototype e-cigarette does not produce chemical constituents at quantifiable levels or background levels using standard industrial hygiene collection techniques and analytical methods.

  19. COMPARISON OF A GENUS-SPECIFIC CONVENTIONAL PCR AND A SPECIES-SPECIFIC NESTED-PCR FOR MALARIA DIAGNOSIS USING FTA COLLECTED SAMPLES FROM KINGDOM OF SAUDI ARABIA.

    PubMed

    Al-Harthi, Saeed A

    2015-12-01

    Molecular tools are increasingly accepted as the most sensitive and reliable techniques for malaria diagnosis and epidemiological surveys. Also, collection of finger prick blood spots onto filter papers is the most simple and affordable method for samples preservation and posterior molecular analysis, especially in rural endemic regions where malaria remains a major health problem. Two malaria molecular diagnostic tests, a Plasmodium genus-specific conventional PCR and a Plasmodium species-specific Nested PCR, were evaluated using DNA templates prepared from Whatman-FTA cards' dry blood spots using both, Methanol-fixation/Heat-extraction and FTA commercial purification kit. A total of 121 blood samples were collected from six Saudi south-western endemic districts both, as thick and thin films for routine microscopic screening and onto FTA cards for molecular studies. Out of the 121 samples, 75 were P. falciparum positive by at least one technique. No other species of Plasmodium were detected. P. falciparum parasites were identified in 69/75 (92%) samples by microscopic screening in health care centers. P. genus-specific PCR was able to amplify P. falciparum DNA in 41/75 (55%) and 59/75 (79%) samples using Methanol-fixation/Heat-extraction and FTA purification kit, respectively. P. species-specific Nested PCR revealed 68/75 (91%) and 75/75 (100%) positive samples using DNA templates were isolated by Methanol-fixation/Heat- extraction and FTA purification methods, respectively. The species-specific Nested PCR applied to Whatman-FTA preserved and processed blood samples represents the best alternative to classical microscopy for malaria diagnosis, particularly in epidemiological screening.

  20. Snow and Ice Mask for the MODIS Aerosol Products

    NASA Technical Reports Server (NTRS)

    Li, Rong-Rong; Remer, Lorraine; Kaufman, Yoram J.; Mattoo, Shana; Gao, Bo-Cai; Vermote, Eric

    2005-01-01

    The atmospheric products have been derived operationally from multichannel imaging data collected with the Moderate Resolution Imaging SpectroRadiometers (MODIS) on board the NASA Terra and Aqua spacecrafts. Preliminary validations of the products were previously reported. Through analysis of more extensive time-series of MODIS aerosol products (Collection 4), we have found that the aerosol products over land areas are slightly contaminated by snow and ice during the springtime snow-melting season. We have developed an empirical technique using MODIS near-IR channels centered near 0.86 and 1.24 pm and a thermal emission channel near 11 pm to mask out these snow-contaminated pixels over land. Improved aerosol retrievals over land have been obtained. Sample results from application of the technique to MODIS data acquired over North America, northern Europe, and northeastern Asia are presented. The technique has been implemented into the MODIS Collection 5 operational algorithm for retrieving aerosols over land from MODIS data.

  1. Histopathological and immunohistochemical approaches for the diagnosis of Pasteurellosis in swine population of Punjab.

    PubMed

    Bhat, Payal; Singh, Nittin Dev; Leishangthem, Geeta Devi; Kaur, Amninder; Mahajan, Vishal; Banga, Harmanjit Singh; Brar, Rajinder Singh

    2016-09-01

    Infectious porcine bronchopneumonia, caused by Pasteurella multocida , is a widespread disease of major economic significance. Thus, the aim of the present study was to diagnose swine Pasteurellosis using gross, histopathological, and immunopathological approaches in the swine population of Punjab and to compare the efficacy of immunohistochemical (IHC) techniques with conventional diagnostic techniques. A total of 71 adult swine lung samples showing gross pneumonic changes were collected along with the associated lymph nodes to carry out the study. The collected samples were then processed for histopathological and IHC studies. Out of the total 71 lung samples, 26 samples were found to be suspected for Pasteurellosis as per the microscopic changes observed, and out of these 26 samples, 16 cases were confirmed to be positive for Pasteurellosis by IHC. Varied macroscopic changes noted in lungs were pneumonic patches with consolidation of many lobes, congestion, and focal hemorrhages. Main lesions associated with lymph nodes were its enlargement and hemorrhages. Histologically, the lung showed fibrinous and suppurative bronchopneumonia, multifocal suppuration, thickening of septa with fibrin combined with cellular infiltration and edema. The higher IHC expression of P. multocida was seen in the bronchial epithelium besides in alveolar and bronchial exudate. Moreover, on comparing the histopathological and IHC scores which were calculated on the basis of characteristic microscopic lesions and number of antigen positive cells, respectively, a significant positive correlation (r=0.4234) was found. It was concluded that swine population of Punjab is having P. multocida infection. The gross and histopathological lesions can be helpful in the preliminary diagnosis of Pasteurellosis but needs to be supplemented by other immunodiagnostic tests. Moreover, IHC technique proved to be a specific, reliable, precise, and rapid technique to supplement these conventional methods of diagnosis for Pasteurellosis.

  2. PubMed Central

    Miezan, T.; Doua, F.; Cattand, P.; de Raadt, P.

    1991-01-01

    The Testryp CATT was performed on dried blood samples on filter-paper and on diluted blood using a microtechnique. This method was applied to both sample collection techniques and was evaluated in parallel with the classical Testryp CATT on whole blood, as described in the instructions provided with the reagents by the manufacturer. A total of 2087 people were tested; 453 samples were tested in the laboratory and 1634 during a field survey in 5 villages of a trypanosomiasis focus in Daloa, Côte d'Ivoire. This study has demonstrated that the Testryp CATT micromethod on either type of sample collection gives results comparable to the Testryp CATT on whole blood. The collection of dried blood samples on filter-paper can be performed by non-specialized staff in trypanosomiasis control programmes of the national health services. In addition, a flask of CATT reagent will allow testing of 6 times more people by the micromethod than by the classical whole-blood method. The micromethod is suitable in the implementation of programmes for the serological surveillance of populations at risk. PMID:1959162

  3. Detection of living cells in stratospheric samples

    NASA Astrophysics Data System (ADS)

    Harris, Melanie J.; Wickramasinghe, N. C.; Lloyd, David; Narlikar, J. V.; Rajaratnam, P.; Turner, Michael P.; Al-Mufti, Shirwan; Wallis, Max K.; Ramadurai, S.; Hoyle, Fred

    2002-02-01

    Air samples collected aseptically over tropical India at various stratospheric altitudes ranging from 20 to 41 km using cryosampler assemblies carried on balloons flown from Hyderabad have shown evidence of living microbial cells. Unambiguous evidence of living cells came from examining micropore filters on which the samples were recovered with the use of voltage sensitive lipophilic dyes that could detect the presents of active cells. Clumps of viable cells were found at all altitudes using this technique, and this conclusion was found to be consistent with images obtained from electron microscopy. Since the 41 km sample was collected well above the local tropopause, a prima facie case for a space incidence of these microorganisms is established. Further work on culturing, PCR analysis and isotopic analysis is in progress.

  4. Manufacture and calibration of optical supersmooth roughness artifacts for intercomparisons

    NASA Astrophysics Data System (ADS)

    Ringel, Gabriele A.; Kratz, Frank; Schmitt, Dirk-Roger; Mangelsdorf, Juergen; Creuzet, Francois; Garratt, John D.

    1995-09-01

    Intercomparison roughness measurements have been carried out on supersmooth artifacts fabricated from BK7, fused silica, and Zerodur. The surface parameters were determined using the optical heterodyne profiler Z5500 (Zygo), a special prototype of the mechanical profiler Nanostep (Rank Taylor Hobson), and an Atomic Force Microscope (Park Scientific Instruments) with an improved acquisition technique. The intercomparison was performed after the range of collected spatial wavelengths for each instrument was adjusted using digital filtering techniques. It is demonstrated for different roughness ranges that the applied superpolishing techniques yield supersmooth artifacts which can be used for more intercomparisons. More than 100 samples were investigated. Criteria were developed to select artifacts from the sample stock.

  5. Mapping of explosive contamination using GC/chemiluminescence and ion mobility spectrometry techniques

    NASA Astrophysics Data System (ADS)

    Miller, Carla J.; Glenn, D. F.; Hartenstein, Steven D.; Hallowell, Susan F.

    1998-12-01

    Recent efforts at the Idaho National Engineering and Environmental Laboratory (INEEL) have included mapping explosive contamination resulting from manufacturing and carrying improvised explosive devices (IEDs). Two types of trace detection equipment were used to determine levels of contamination from designated sampling areas. A total of twenty IEDs were constructed: ten using TNT and ten using C-4. Two test scenarios were used. The first scenario tracked the activities of a manufacturer who straps the device onto an independent courier. The courier then performed a series of activities to simulate waiting in an airport. The second scenario tracked the activities of a manufacturer who also served as the courier. A sample set for each test consisted of thirty samples from various locations on each IED manufacturer, thirty from each IED courier, twenty-five from the manufacturing area, and twenty-five from the courier area. Pre-samples and post-samples were collected for analysis with each detection technique. Samples analyzed by gc/chemiluminescence were taken by swiping a teflon- coated sampling swipe across the surface of the sampling area to pick up any explosive particles. Samples analyzed by ion mobility spectrometry (IMS) were taken from the clothing of the manufacturer and courier by vacuuming the surface and collecting particulates on a fiberglass filter. Samples for IMS analysis from the manufacturing and courier rooms were taken by wiping a cotton sampling swipe across the surface area. Currently, building IEDs and monitoring the explosive contamination is being directed toward detection with portal monitors.

  6. Autonomous spatially adaptive sampling in experiments based on curvature, statistical error and sample spacing with applications in LDA measurements

    NASA Astrophysics Data System (ADS)

    Theunissen, Raf; Kadosh, Jesse S.; Allen, Christian B.

    2015-06-01

    Spatially varying signals are typically sampled by collecting uniformly spaced samples irrespective of the signal content. For signals with inhomogeneous information content, this leads to unnecessarily dense sampling in regions of low interest or insufficient sample density at important features, or both. A new adaptive sampling technique is presented directing sample collection in proportion to local information content, capturing adequately the short-period features while sparsely sampling less dynamic regions. The proposed method incorporates a data-adapted sampling strategy on the basis of signal curvature, sample space-filling, variable experimental uncertainty and iterative improvement. Numerical assessment has indicated a reduction in the number of samples required to achieve a predefined uncertainty level overall while improving local accuracy for important features. The potential of the proposed method has been further demonstrated on the basis of Laser Doppler Anemometry experiments examining the wake behind a NACA0012 airfoil and the boundary layer characterisation of a flat plate.

  7. Apollo-11 lunar sample information catalogue

    NASA Technical Reports Server (NTRS)

    Kramer, F. E. (Compiler); Twedell, D. B. (Compiler); Walton, W. J. A., Jr. (Compiler)

    1977-01-01

    The Apollo 11 mission is reviewed with emphasis on the collection of lunar samples, their geologic setting, early processing, and preliminary examination. The experience gained during five subsequent missions was applied to obtain physical-chemical data for each sample using photographic and binocular microscope techniques. Topics discussed include: binocular examination procedure; breccia clast dexrriptuons, thin section examinations procedure typical breccia in thin section, typical basalt in thin section, sample histories, and chemical and age data. An index to photographs is included.

  8. Characterisation and discrimination of various types of lac resin using gas chromatography mass spectrometry techniques with quaternary ammonium reagents.

    PubMed

    Sutherland, K; del Río, J C

    2014-04-18

    A variety of lac resin samples obtained from artists' suppliers, industrial manufacturers, and museum collections were analysed using gas chromatography mass spectrometry (GCMS) and reactive pyrolysis GCMS with quaternary ammonium reagents. These techniques allowed a detailed chemical characterisation of microgram-sized samples, based on the detection and identification of derivatives of the hydroxy aliphatic and cyclic (sesquiterpene) acids that compose the resin. Differences in composition could be related to the nature of the resin, e.g. wax-containing (unrefined), bleached, or aged samples. Furthermore, differences in the relative abundances of aliphatic hydroxyacids appear to be associated with the biological source of the resin. The diagnostic value of newly characterised lac components, including 8-hydroxyacids, is discussed here for the first time. Identification of derivatised components was aided by AMDIS deconvolution software, and discrimination of samples was enhanced by statistical evaluation of data using principal component analysis. The robustness of the analyses, together with the minimal sample size required, make these very powerful approaches for the characterisation of lac resin in museum objects. The value of such analyses for enhancing the understanding of museum collections is illustrated by two case studies of objects in the collection of the Philadelphia Museum of Art: a restorer's varnish on a painting by Luca Signorelli, and a pictorial inlay in an early nineteenth-century High Chest by George Dyer. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Acid-etching technique of non-decalcified bone samples for visualizing osteocyte-lacuno-canalicular network using scanning electron microscope.

    PubMed

    Lampi, Tiina; Dekker, Hannah; Ten Bruggenkate, Chris M; Schulten, Engelbert A J M; Mikkonen, Jopi J W; Koistinen, Arto; Kullaa, Arja M

    2018-01-01

    The aim of this study was to define the acid-etching technique for bone samples embedded in polymethyl metacrylate (PMMA) in order to visualize the osteocyte lacuno-canalicular network (LCN) for scanning electron microscopy (SEM). Human jaw bone tissue samples (N = 18) were collected from the study population consisting of patients having received dental implant surgery. After collection, the bone samples were fixed in 70% ethanol and non-decalcified samples embedded routinely into polymethyl metacrylate (PMMA). The PMMA embedded specimens were acid-etched in either 9 or 37% phosphoric acid (PA) and prepared for SEM for further analysis. PMMA embedded bone specimens acid-etched by 9% PA concentration accomplishes the most informative and favorable visualization of the LCN to be observed by SEM. Etching of PMMA embedded specimens is recommendable to start with 30 s or 40 s etching duration in order to find the proper etching duration for the samples examined. Visualizing osteocytes and LCN provides a tool to study bone structure that reflects changes in bone metabolism and diseases related to bone tissue. By proper etching protocol of non-decalcified and using scanning electron microscope it is possible to visualize the morphology of osteocytes and the network supporting vitality of bone tissue.

  10. Use of Multiple Displacement Amplification as Pre-polymerase Chain Reaction (Pre-PCR) to amplify genomic DNA of siphonapterids preserved for long periods in scientific collections.

    PubMed

    Avelar, Daniel M; Linardi, Pedro M

    2010-09-15

    The recently developed Multiple Displacement Amplification technique (MDA) allows for the production of a large quantity of high quality genomic DNA from low amounts of the original DNA. The goal of this study was to evaluate the performance of the MDA technique to amplify genomic DNA of siphonapterids that have been stored for long periods in 70% ethanol at room temperature. We subjected each DNA sample to two different methodologies: (1) amplification of mitochondrial 16S sequences without MDA; (2) amplification of 16S after MDA. All the samples obtained from these procedures were then sequenced. Only 4 samples (15.4%) subjected to method 1 showed amplification. In contrast, the application of MDA (method 2) improved the performance substantially, with 24 samples (92.3%) showing amplification, with significant difference. Interestingly, one of the samples successfully amplified with this method was originally collected in 1909. All of the sequenced samples displayed satisfactory results in quality evaluations (Phred ≥ 20) and good similarities, as identified with the BLASTn tool. Our results demonstrate that the use of MDA may be an effective tool in molecular studies involving specimens of fleas that have traditionally been considered inadequately preserved for such purposes.

  11. Use of Multiple Displacement Amplification as Pre-polymerase Chain Reaction (Pre-PCR) to amplify genomic DNA of siphonapterids preserved for long periods in scientific collections

    PubMed Central

    2010-01-01

    The recently developed Multiple Displacement Amplification technique (MDA) allows for the production of a large quantity of high quality genomic DNA from low amounts of the original DNA. The goal of this study was to evaluate the performance of the MDA technique to amplify genomic DNA of siphonapterids that have been stored for long periods in 70% ethanol at room temperature. We subjected each DNA sample to two different methodologies: (1) amplification of mitochondrial 16S sequences without MDA; (2) amplification of 16S after MDA. All the samples obtained from these procedures were then sequenced. Only 4 samples (15.4%) subjected to method 1 showed amplification. In contrast, the application of MDA (method 2) improved the performance substantially, with 24 samples (92.3%) showing amplification, with significant difference. Interestingly, one of the samples successfully amplified with this method was originally collected in 1909. All of the sequenced samples displayed satisfactory results in quality evaluations (Phred ≥ 20) and good similarities, as identified with the BLASTn tool. Our results demonstrate that the use of MDA may be an effective tool in molecular studies involving specimens of fleas that have traditionally been considered inadequately preserved for such purposes. PMID:20840790

  12. Rapid methods for jugular bleeding of dogs requiring one technician.

    PubMed

    Frisk, C S; Richardson, M R

    1979-06-01

    Two methods were used to collect blood from the jugular vein of dogs. In both techniques, only one technician was required. A rope with a slip knot was placed around the base of the neck to assist in restraint and act as a tourniquet for the vein. The technician used one hand to restrain the dog by the muzzle and position the head. The other hand was used for collecting the sample. One of the methods could be accomplished with the dog in its cage. The bleeding techniques were rapid, requiring approximately 1 minute per dog.

  13. Application of mass spectrometry to process control for polymer material in autoclave curing

    NASA Technical Reports Server (NTRS)

    Smith, A. C.

    1983-01-01

    Mass spectrometer analysis of gas samples collected during a cure cycle of polymer materials can be used as a process control technique. This technique is particularly helpful in studying the various types of solvents and resin systems used in the preparation of polymer materials and characterizing the chemical composition of different resin systems and their mechanism of polymerization.

  14. Repeatability of riparian vegetation sampling methods: how useful are these techniques for broad-scale, long-term monitoring?

    Treesearch

    Marc C. Coles-Ritchie; Richard C. Henderson; Eric K. Archer; Caroline Kennedy; Jeffrey L. Kershner

    2004-01-01

    Tests were conducted to evaluate variability among observers for riparian vegetation data collection methods and data reduction techniques. The methods are used as part of a largescale monitoring program designed to detect changes in riparian resource conditions on Federal lands. Methods were evaluated using agreement matrices, the Bray-Curtis dissimilarity metric, the...

  15. On algorithmic optimization of histogramming functions for GEM systems

    NASA Astrophysics Data System (ADS)

    Krawczyk, Rafał D.; Czarski, Tomasz; Kolasinski, Piotr; Poźniak, Krzysztof T.; Linczuk, Maciej; Byszuk, Adrian; Chernyshova, Maryna; Juszczyk, Bartlomiej; Kasprowicz, Grzegorz; Wojenski, Andrzej; Zabolotny, Wojciech

    2015-09-01

    This article concerns optimization methods for data analysis for the X-ray GEM detector system. The offline analysis of collected samples was optimized for MATLAB computations. Compiled functions in C language were used with MEX library. Significant speedup was received for both ordering-preprocessing and for histogramming of samples. Utilized techniques with obtained results are presented.

  16. Implementation of Structured Inquiry Based Model Learning toward Students' Understanding of Geometry

    ERIC Educational Resources Information Center

    Salim, Kalbin; Tiawa, Dayang Hjh

    2015-01-01

    The purpose of this study is implementation of a structured inquiry learning model in instruction of geometry. The model used is a model with a quasi-experimental study amounted to two classes of samples selected from the population of the ten classes with cluster random sampling technique. Data collection tool consists of a test item…

  17. Early detection of foot-and-mouth disease virus from infected cattle using a dry filter air sampling system

    USDA-ARS?s Scientific Manuscript database

    Foot-and-mouth disease (FMD) is a highly contagious livestock disease of high economic impact. Early detection of FMD virus (FMDV) is fundamental for rapid outbreak control. Air sampling collection has been demonstrated as a useful technique for detection of FMDV RNA in infected animals, related to ...

  18. Basic tree-ring sample preparation techniques for aging aspen

    Treesearch

    Lance A. Asherin; Stephen A. Mata

    2001-01-01

    Aspen is notoriously difficult to age because of its light-colored wood and faint annual growth rings. Careful preparation and processing of aspen ring samples can overcome these problems, yield accurate age and growth estimates, and concisely date disturbance events present in the tree-ring record. Proper collection of aspen wood is essential in obtaining usable ring...

  19. Determination of polybrominated diphenyl ethers (PBDEs) in dust samples collected in air conditioning filters of different usage - method development.

    PubMed

    Śmiełowska, M; Zabiegała, B

    2018-06-19

    This study presents the results of studies aimed at the development of an analytical procedure for separation, identification, and determination of PBDEs compounds in dust samples collected from automotive cabin air filters and samples collected from filters installed as part of the air purification system in academic facilities. Ultrasound-assisted dispersive solid phase extraction (UA-dSPE) was found to perform better in terms of extract purification than the conventional SPE technique. GC-EIMS was used for final determination of analytes. The concentrations of PBDEs in car filters ranged from < LOD to 688 ng/g while from < LOD to 247 ng/g in dust from air conditioning filters. BDE-47 and BDE-100 were reported the dominating congeners. The estimated exposure to PBDEs via ingestion of dust from car filters varied from 0.00022 to 0.012 ng/day in toddlers and from 0.000036 to 0.0029 ng/day in adults; dust from air conditioning filters: from 0.017 to 0.25 ng/day in toddlers and from 0.0029 to 0.042 ng/day. In addition, an attempt was made at extracting PBDEs from a dust samples using the matrix solid-phase dispersion (MSPD) technique as a promising alternative to conventional SPE separations. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Concentration of gold in natural waters

    USGS Publications Warehouse

    McHugh, J.B.

    1988-01-01

    The purpose of this paper is to investigate the amount of gold present in natural waters. One hundred and thirty-two natural water samples were collected from various sources and analyzed for gold by the latest techniques. Background values for gold in natural waters range from <0.001 to 0.005 ppb, and anomalous values range from 0.010 to 2.8 ppb. Waters collected from mineralized areas have a mean gold value of 0.101 ppb, whereas waters collected from unmineralized areas have a mean of 0.002 ppb. Some of the high gold values reported in the earlier literature were probably due to interferences by high salt content in the sample and/or lack of proper filter procedures. ?? 1988.

  1. The Internet of Samples in the Earth Sciences: Providing Access to Uncurated Collections

    NASA Astrophysics Data System (ADS)

    Carter, M. R.; Lehnert, K. A.

    2014-12-01

    Vast amounts of physical samples have been collected in the Earth Sciences for studies that address a wide range of scientific questions. Only a fraction of these samples are well curated and preserved long-term in sample repositories and museums. Many samples and collections are stored in the offices and labs of investigators, or in basements and sheds of institutions and investigators' homes. These 'uncurated' collections often contain samples that have been well studied, or are unique and irreplaceable. They may also include samples that could reveal new insights if re-analyzed using new techniques, or specimens that could have unanticipated relevance to research being conducted in fields other than the one for which they were collected. Currently, these samples cannot be accessed or discovered online by the broader science community. Investigators and departments often lack the resources to properly catalog and curate the samples and respond to requests for splits. Long-term preservation of and access to these samples is usually not provided for. iSamplES, a recently-funded EarthCube Research Coordination Network (RCN), seeks to integrate scientific samples, including 'uncurated' samples, into digital data and information infrastructure in the Earth Sciences and to facilitate their curation, discovery, access, sharing, and analysis. The RCN seeks to develop and implement best practices that increase digital access to samples with the goal of establishing a comprehensive infrastructure not only for the digital, but also physical curation of samples. The RCN will engage a broad group of individuals from domain scientists to curators to publishers to computer scientists to define, articulate, and address the needs and challenges of digital sample management and recommend community-endorsed best practices and standards for registering, describing, identifying, and citing physical specimens, drawing upon other initiatives and existing or emerging software tools for digital sample and collection management. Community engagement will include surveys, in-person workshops and outreach events, the creation of the iSamplES knowledge hub (semantic wiki) and a registry of collections. iSamplES will specifically engage early career scientists to encourage that no samples go uncurated.

  2. Evaluation of two-dimensional electrophoresis and liquid chromatography – tandem mass spectrometry for tissue-specific protein profiling of laser-microdissected plant samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schad, Martina; Lipton, Mary S.; Giavalisco, Patrick

    2005-07-14

    Laser microdissection (LM) allows the collection of homogeneous tissue- and cell specific plant samples. The employment of this technique with subsequent protein analysis has thus far not been reported for plant tissues, probably due to the difficulties associated with defining a reasonable cellular morphology and, in parallel, allowing efficient protein extraction from tissue samples. The relatively large sample amount needed for successful proteome analysis is an additional issue that complicates protein profiling on a tissue- or even cell-specific level. In contrast to transcript profiling that can be performed from very small sample amounts due to efficient amplification strategies, there ismore » as yet no amplification procedure for proteins available. In the current study, we compared different tissue preparation techniques prior to LM/laser pressure catapulting (LMPC) with respect to their suitability for protein retrieval. Cryosectioning was identified as the best compromise between tissue morphology and effective protein extraction. After collection of vascular bundles from Arabidopsis thaliana stem tissue by LMPC, proteins were extracted and subjected to protein analysis, either by classical two-dimensional gel electrophoresis (2-DE), or by high-efficiency liquid chromatography (LC) in conjunction with tandem mass spectrometry (MS/MS). Our results demonstrate that both methods can be used with LMPC collected plant material. But because of the significantly lower sample amount required for LC-MS/MS than for 2-DE, the combination of LMPC and LC-MS/MS has a higher potential to promote comprehensive proteome analysis of specific plant tissues.« less

  3. Comparison of the biopsy and cytobrush techniques for diagnosis of subclinical endometritis in mares

    PubMed Central

    2014-01-01

    Background Endometritis is a major cause of infertility in the mare. Therefore, the diagnosis of this disease is very important in veterinary practice. The objective of this study was to compare bacteriological and cytological results obtained from the mare uterus using biopsy (EB) and cytobrush (CB) techniques and relating these findings to the presence of polymorphonuclear cells (PMNs) in endometrial tissue as the gold standard for detection of endometritis. In particular, we tested the hypothesis that endometrial cytology and microbiology data obtained from material collected using the EB and CB techniques are similar, so that the CB technique could preferentially be used to detect subclinical endometritis in clinical practice. Methods A total of 69 mares suspected of subclinical endometritis because of previous reproductive history and 15 maiden mares were enrolled in this study. Material collected from both EB and CB was smeared on sterile glass slides for cytological examinations and on culture media for microbiological examinations. Bacteriological cultures and cytological samples were classified as negative (no growth or mixed cultures of more than three microorganisms; <2% PMNs) or positive (pure growth of microorganisms; >2% PMNs) for endometritis. Results Positive growth was observed in 43% of CB samples and in 54% of EB samples (difference not significant). The growth of β-hemolytic streptococci was always connected with positive cytology. This relationship was not observed for growth of E. coli or for non-pathogenic flora. The sensitivity of bacterial growth and cytology from EB was 0.63 and 0.73 respectively. The sensitivities of bacterial growth and cytology from CB were 0.50 and 0.71 respectively. Conclusion Microbiological and cytological results obtained from CB are similar to those obtained from EB and based on these findings the CB technique may be recommended for collection of materials from the mare’s uterus in clinical practice. PMID:24708825

  4. An orientation soil survey at the Pebble Cu-Au-Mo porphyry deposit, Alaska

    USGS Publications Warehouse

    Smith, Steven M.; Eppinger, Robert G.; Fey, David L.; Kelley, Karen D.; Giles, S.A.

    2009-01-01

    Soil samples were collected in 2007 and 2008 along three traverses across the giant Pebble Cu-Au-Mo porphyry deposit. Within each soil pit, four subsamples were collected following recommended protocols for each of ten commonly-used and proprietary leach/digestion techniques. The significance of geochemical patterns generated by these techniques was classified by visual inspection of plots showing individual element concentration by each analytical method along the 2007 traverse. A simple matrix by element versus method, populated with a value based on the significance classification, provides a method for ranking the utility of methods and elements at this deposit. The interpretation of a complex multi-element dataset derived from multiple analytical techniques is challenging. An example of vanadium results from a single leach technique is used to illustrate the several possible interpretations of the data.

  5. Raman sorting and identification of single living micro-organisms with optical tweezers

    NASA Astrophysics Data System (ADS)

    Xie, Changan; Chen, De; Li, Yong-Qing

    2005-07-01

    We report on a novel technique for sorting and identification of single biological cells and food-borne bacteria based on laser tweezers and Raman spectroscopy (LTRS). With this technique, biological cells of different physiological states in a sample chamber were identified by their Raman spectral signatures and then they were selectively manipulated into a clean collection chamber with optical tweezers through a microchannel. As an example, we sorted the live and dead yeast cells into the collection chamber and validated this with a standard staining technique. We also demonstrated that bacteria existing in spoiled foods could be discriminated from a variety of food particles based on their characteristic Raman spectra and then isolated with laser manipulation. This label-free LTRS sorting technique may find broad applications in microbiology and rapid examination of food-borne diseases.

  6. Insights into organic-aerosol sources via a novel laser-desorption/ionization mass spectrometry technique applied to one year of PM10 samples from nine sites in central Europe

    NASA Astrophysics Data System (ADS)

    Daellenbach, Kaspar R.; El-Haddad, Imad; Karvonen, Lassi; Vlachou, Athanasia; Corbin, Joel C.; Slowik, Jay G.; Heringa, Maarten F.; Bruns, Emily A.; Luedin, Samuel M.; Jaffrezo, Jean-Luc; Szidat, Sönke; Piazzalunga, Andrea; Gonzalez, Raquel; Fermo, Paola; Pflueger, Valentin; Vogel, Guido; Baltensperger, Urs; Prévôt, André S. H.

    2018-02-01

    We assess the benefits of offline laser-desorption/ionization mass spectrometry in understanding ambient particulate matter (PM) sources. The technique was optimized for measuring PM collected on quartz-fiber filters using silver nitrate as an internal standard for m/z calibration. This is the first application of this technique to samples collected at nine sites in central Europe throughout the entire year of 2013 (819 samples). Different PM sources were identified by positive matrix factorization (PMF) including also concomitant measurements (such as NOx, levoglucosan, and temperature). By comparison to reference mass spectral signatures from laboratory wood burning experiments as well as samples from a traffic tunnel, three biomass burning factors and two traffic factors were identified. The wood burning factors could be linked to the burning conditions; the factors related to inefficient burns had a larger impact on air quality in southern Alpine valleys than in northern Switzerland. The traffic factors were identified as primary tailpipe exhaust and most possibly aged/secondary traffic emissions. The latter attribution was supported by radiocarbon analyses of both the organic and elemental carbon. Besides these sources, factors related to secondary organic aerosol were also separated. The contribution of the wood burning emissions based on LDI-PMF (laser-desorption/ionization PMF) correlates well with that based on AMS-PMF (aerosol mass spectrometer PMF) analyses, while the comparison between the two techniques for other components is more complex.

  7. The application of compressed sensing to long-term acoustic emission-based structural health monitoring

    NASA Astrophysics Data System (ADS)

    Cattaneo, Alessandro; Park, Gyuhae; Farrar, Charles; Mascareñas, David

    2012-04-01

    The acoustic emission (AE) phenomena generated by a rapid release in the internal stress of a material represent a promising technique for structural health monitoring (SHM) applications. AE events typically result in a discrete number of short-time, transient signals. The challenge associated with capturing these events using classical techniques is that very high sampling rates must be used over extended periods of time. The result is that a very large amount of data is collected to capture a phenomenon that rarely occurs. Furthermore, the high energy consumption associated with the required high sampling rates makes the implementation of high-endurance, low-power, embedded AE sensor nodes difficult to achieve. The relatively rare occurrence of AE events over long time scales implies that these measurements are inherently sparse in the spike domain. The sparse nature of AE measurements makes them an attractive candidate for the application of compressed sampling techniques. Collecting compressed measurements of sparse AE signals will relax the requirements on the sampling rate and memory demands. The focus of this work is to investigate the suitability of compressed sensing techniques for AE-based SHM. The work explores estimating AE signal statistics in the compressed domain for low-power classification applications. In the event compressed classification finds an event of interest, ι1 norm minimization will be used to reconstruct the measurement for further analysis. The impact of structured noise on compressive measurements is specifically addressed. The suitability of a particular algorithm, called Justice Pursuit, to increase robustness to a small amount of arbitrary measurement corruption is investigated.

  8. Exploring Student Teachers' Views on ePortfolios as an Empowering Tool to Enhance Self-Directed Learning in an Online Teacher Education Course

    ERIC Educational Resources Information Center

    van Wyk, Micheal M.

    2017-01-01

    This paper explores Economics student teachers' views on ePortfolios as an empowering tool to enhance self-directed learning in an online teacher education course. An interpretive phenomenological research approach was employed for data collection and a purposive convenient sampling technique was selected to collect data. Only Postgraduate…

  9. Arthropod Surveillance Programs: Basic Components, Strategies, and Analysis.

    PubMed

    Cohnstaedt, Lee W; Rochon, Kateryn; Duehl, Adrian J; Anderson, John F; Barrera, Roberto; Su, Nan-Yao; Gerry, Alec C; Obenauer, Peter J; Campbell, James F; Lysyk, Tim J; Allan, Sandra A

    2012-03-01

    Effective entomological surveillance planning stresses a careful consideration of methodology, trapping technologies, and analysis techniques. Herein, the basic principles and technological components of arthropod surveillance plans are described, as promoted in the symposium "Advancements in arthropod monitoring technology, techniques, and analysis" presented at the 58th annual meeting of the Entomological Society of America in San Diego, CA. Interdisciplinary examples of arthropod monitoring for urban, medical, and veterinary applications are reviewed. Arthropod surveillance consists of the three components: 1) sampling method, 2) trap technology, and 3) analysis technique. A sampling method consists of selecting the best device or collection technique for a specific location and sampling at the proper spatial distribution, optimal duration, and frequency to achieve the surveillance objective. Optimized sampling methods are discussed for several mosquito species (Diptera: Culicidae) and ticks (Acari: Ixodidae). The advantages and limitations of novel terrestrial and aerial insect traps, artificial pheromones and kairomones are presented for the capture of red flour beetle (Coleoptera: Tenebrionidae), small hive beetle (Coleoptera: Nitidulidae), bed bugs (Hemiptera: Cimicidae), and Culicoides (Diptera: Ceratopogonidae) respectively. After sampling, extrapolating real world population numbers from trap capture data are possible with the appropriate analysis techniques. Examples of this extrapolation and action thresholds are given for termites (Isoptera: Rhinotermitidae) and red flour beetles.

  10. Arthropod Surveillance Programs: Basic Components, Strategies, and Analysis

    PubMed Central

    Rochon, Kateryn; Duehl, Adrian J.; Anderson, John F.; Barrera, Roberto; Su, Nan-Yao; Gerry, Alec C.; Obenauer, Peter J.; Campbell, James F.; Lysyk, Tim J.; Allan, Sandra A.

    2015-01-01

    Effective entomological surveillance planning stresses a careful consideration of methodology, trapping technologies, and analysis techniques. Herein, the basic principles and technological components of arthropod surveillance plans are described, as promoted in the symposium “Advancements in arthropod monitoring technology, techniques, and analysis” presented at the 58th annual meeting of the Entomological Society of America in San Diego, CA. Interdisciplinary examples of arthropod monitoring for urban, medical, and veterinary applications are reviewed. Arthropod surveillance consists of the three components: 1) sampling method, 2) trap technology, and 3) analysis technique. A sampling method consists of selecting the best device or collection technique for a specific location and sampling at the proper spatial distribution, optimal duration, and frequency to achieve the surveillance objective. Optimized sampling methods are discussed for several mosquito species (Diptera: Culicidae) and ticks (Acari: Ixodidae). The advantages and limitations of novel terrestrial and aerial insect traps, artificial pheromones and kairomones are presented for the capture of red flour beetle (Coleoptera: Tenebrionidae), small hive beetle (Coleoptera: Nitidulidae), bed bugs (Hemiptera: Cimicidae), and Culicoides (Diptera: Ceratopogonidae) respectively. After sampling, extrapolating real world population numbers from trap capture data are possible with the appropriate analysis techniques. Examples of this extrapolation and action thresholds are given for termites (Isoptera: Rhinotermitidae) and red flour beetles. PMID:26543242

  11. Quantitative filter forensics for indoor particle sampling.

    PubMed

    Haaland, D; Siegel, J A

    2017-03-01

    Filter forensics is a promising indoor air investigation technique involving the analysis of dust which has collected on filters in central forced-air heating, ventilation, and air conditioning (HVAC) or portable systems to determine the presence of indoor particle-bound contaminants. In this study, we summarize past filter forensics research to explore what it reveals about the sampling technique and the indoor environment. There are 60 investigations in the literature that have used this sampling technique for a variety of biotic and abiotic contaminants. Many studies identified differences between contaminant concentrations in different buildings using this technique. Based on this literature review, we identified a lack of quantification as a gap in the past literature. Accordingly, we propose an approach to quantitatively link contaminants extracted from HVAC filter dust to time-averaged integrated air concentrations. This quantitative filter forensics approach has great potential to measure indoor air concentrations of a wide variety of particle-bound contaminants. Future studies directly comparing quantitative filter forensics to alternative sampling techniques are required to fully assess this approach, but analysis of past research suggests the enormous possibility of this approach. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. The Astromaterials X-Ray Computed Tomography Laboratory at Johnson Space Center

    NASA Technical Reports Server (NTRS)

    Zeigler, R. A.; Coleff, D. M.; McCubbin, F. M.

    2017-01-01

    The Astromaterials Acquisition and Curation Office at NASA's Johnson Space Center (hereafter JSC curation) is the past, present, and future home of all of NASA's astromaterials sample collections. JSC curation currently houses all or part of nine different sample collections: (1) Apollo samples (1969), (2) Lunar samples (1972), (3) Antarctic meteorites (1976), (4) Cosmic Dust particles (1981), (5) Microparticle Impact Collection (1985), (6) Genesis solar wind atoms (2004); (7) Stardust comet Wild-2 particles (2006), (8) Stardust interstellar particles (2006), and (9) Hayabusa asteroid Itokawa particles (2010). Each sample collection is housed in a dedicated clean room, or suite of clean rooms, that is tailored to the requirements of that sample collection. Our primary goals are to maintain the long-term integrity of the samples and ensure that the samples are distributed for scientific study in a fair, timely, and responsible manner, thus maximizing the return on each sample. Part of the curation process is planning for the future, and we also perform fundamental research in advanced curation initiatives. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of sample collections, or getting new results from existing sample collections [2]. We are (and have been) planning for future curation, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, and curation of organically- and biologically-sensitive samples. As part of these advanced curation efforts we are augmenting our analytical facilities as well. A micro X-Ray computed tomography (micro-XCT) laboratory dedicated to the study of astromaterials will be coming online this spring within the JSC Curation office, and we plan to add additional facilities that will enable nondestructive (or minimally-destructive) analyses of astromaterials in the near future (micro-XRF, confocal imaging Raman Spectroscopy). These facilities will be available to: (1) develop sample handling and storage techniques for future sample return missions; (2) be utilized by PET for future sample return missions; (3) be used for retroactive PET (Positron Emission Tomography)-style analyses of our existing collections; and (4) for periodic assessments of the existing sample collections. Here we describe the new micro-XCT system, as well as some of the ongoing or anticipated applications of the instrument.

  13. Studying the spatial variability of Cr in agricultural field using both particle induced X-ray emission (PIXE) and instrumental neutron activation analysis (INAA) technique

    NASA Astrophysics Data System (ADS)

    Cruvinel, Paulo E.; Crestana, Sílvio; Artaxo, Paulo; Martins, JoséV.; Armelin, Maria JoséA.

    1996-04-01

    In the field of soil physics, a technique which permits a non-destructive, accurate and fast elemental analysis with a minimum of sample preparation effort is often desired. Although trace elements are minor components of the solid phase, they play an important role in soil fertility. Cr is of nutritional importance because it is a required element in human and animal nutrition. The immobility of Cr may be responsible for an inadequate Cr supply to plants. This work not only demonstrates the suitability of PIXE as a fast and non-destructive technique, useful to measure Cr content in soil samples, but also outlines a study of spatial variability of that element in agricultural field. To demonstrate the capability of the method soil samples were collected in a 5000 m 2 agricultural field. The soil samples were analyzed using both PIXE and INAA techniques. Besides, a Fourier interpolation technique was used to verify the distribution of Cr along of the sampled field. INAA was carried out by means of the γ-ray emitted by 51Cr(320 keV). Results show that there is a good linear relationship between the elemental concentration of Cr obtained using those techniques, i.e. a correlation coefficient of r2 = 0.82 was achieved.

  14. Direct observation of nitrate and sulfate formations from mineral dust and sea-salts using low- Z particle electron probe X-ray microanalysis

    NASA Astrophysics Data System (ADS)

    Hwang, HeeJin; Ro, Chul-Un

    In the present work, it is demonstrated that a single particle analytical technique, named low- Z particle electron probe X-ray microanalysis, is a practically useful tool for the study of heterogeneous reactions of mineral dust and sea-salts when this analytical technique was applied to a sample collected during an Asian Dust storm event. The technique does not require a special treatment of sample to identify particles reacted in the air. Also, quantitative chemical speciation of reacted particles can provide concrete information on what chemical reaction, if any, occurred for individual particles. Among overall 178 analyzed particles, the number of reacted particles is 81 and heterogeneous chemical reactions mostly occurred on CaCO 3 mineral dust (54 particles) and sea-salts (26 particles). Several observations made for the Asian Dust sample in the present work are: (1) CaCO 3 species almost completely reacted to produce mostly Ca(NO 3) 2 species, and CaSO 4 to a much lesser extent. (2) When reacted particles contain CaSO 4, almost all of them are internally mixed with nitrate. (3) Reacted CaCO 3 particles seem to contain moisture when they were collected. (4) Some reacted CaCO 3 particles have unreacted mineral species, such as aluminosilicates, iron oxide, SiO 2, etc., in the core region. (5) All sea-salt particles are observed to have reacted in the air. Some of them were recrystallized in the air before being collected and they are observed as crystalline NaNO 3 particles. (6) Many sea-salts were collected as water drops, and some of them were fractionally recrystallized on Ag collecting substrate. When sea-salts were not recrystallized on the substrate, they are found as particles internally mixed with NaNO 3 and Mg(NO 3) 2, and in some cases SO 4 and Cl species as additional anions.

  15. Sweat Sodium, Potassium, and Chloride Concentrations Analyzed Same Day as Collection Versus After 7 Days Storage in a Range of Temperatures.

    PubMed

    Baker, Lindsay B; Barnes, Kelly A; Sopeña, Bridget C; Nuccio, Ryan P; Reimel, Adam J; Ungaro, Corey T

    2018-05-22

    The purpose of this study was to determine the effect of storage temperature on sodium ([Na + ]), potassium ([K + ]), and chloride ([Cl - ]) concentrations of sweat samples analyzed 7 days after collection. Using the absorbent patch technique, 845 sweat samples were collected from 39 subjects (32 ± 7 years, 72.9 ± 10.5 kg) during exercise. On the same day as collection (PRESTORAGE), 609 samples were analyzed for [Na + ], [Cl - ], and [K + ] by ion chromatography (IC) and 236 samples were analyzed for [Na + ] using a compact ion-selective electrode (ISE). Samples were stored at one of the four conditions: -20 °C (IC, n = 138; ISE, n = 60), 8 °C (IC, n = 144; ISE, n = 59), 23 °C (IC, n = 159; ISE, n = 59), or alternating between 8 °C and 23 °C (IC, n = 168; ISE, n = 58). After 7 days in storage (POSTSTORAGE), samples were reanalyzed using the same technique as PRESTORAGE. PRESTORAGE sweat electrolyte concentrations were highly related to that of POSTSTORAGE (intraclass correlation coefficient: .945-.989, p < .001). Mean differences (95% confidence intervals) between PRESTORAGE and POSTSTORAGE were statistically, but not practically, significant for most comparisons: IC [Na + ]: -0.5(0.9) to -2.1(0.9) mmol/L; IC [K + ]: -0.1(0.1) to -0.2(0.1) mmol/L; IC [Cl - ]: -0.4(1.4) to -1.3(1.3) mmol/L; ISE [Na + ]: -2.0(1.1) to 1.3(1.1) mmol/L. Based on typical error of measurement results, 95% of the time PRESTORAGE and POSTSTORAGE sweat [Na + ], [K + ], and [Cl - ] by IC analysis fell within ±7-9, ±0.6-0.7, and ±9-13 mmol/L, respectively, while sweat [Na + ] by ISE was ±6 mmol/L. All conditions produced high reliability and acceptable levels of agreement in electrolyte concentrations of sweat samples analyzed on the day of collection versus after 7 days in storage.

  16. [Parasites of zoonotic importance in dog feces collected in parks and public squares of the city of Los Angeles, Bío-Bío, Chile].

    PubMed

    Luzio, Álvaro; Belmar, Pablo; Troncoso, Ignacio; Luzio, Patricia; Jara, Alexis; Fernández, Ítalo

    2015-08-01

    The contamination of public squares and parks with dog feces poses a risk to the population, since it may contain parasitic elements of zoonotic importance. To identify human pathogenic parasites in samples of dog feces collected from parks and public squares. 452 fecal dog samples collected from 65 squares and public parks were analyzed using the technique of Burrows. 60% (39/65) of the samples contained some parasitic forms with a zoonotic potential. Parasitic taxa with zoonotic risk were Toxocara sp., Ancylostoma sp., Dipylidium caninum, Giardia sp., Taenia sp., Toxascaris sp., Strongyloides sp., and Uncinaria sp. The detected parasites present a risk to human health, so it seems necessary to implement health education activities in the community, develop deworming plans, and control the canine overpopulation.

  17. Comprehensive Non-Destructive Conservation Documentation of Lunar Samples Using High-Resolution Image-Based 3D Reconstructions and X-Ray CT Data

    NASA Technical Reports Server (NTRS)

    Blumenfeld, E. H.; Evans, C. A.; Oshel, E. R.; Liddle, D. A.; Beaulieu, K.; Zeigler, R. A.; Hanna, R. D.; Ketcham, R. A.

    2015-01-01

    Established contemporary conservation methods within the fields of Natural and Cultural Heritage encourage an interdisciplinary approach to preservation of heritage material (both tangible and intangible) that holds "Outstanding Universal Value" for our global community. NASA's lunar samples were acquired from the moon for the primary purpose of intensive scientific investigation. These samples, however, also invoke cultural significance, as evidenced by the millions of people per year that visit lunar displays in museums and heritage centers around the world. Being both scientifically and culturally significant, the lunar samples require a unique conservation approach. Government mandate dictates that NASA's Astromaterials Acquisition and Curation Office develop and maintain protocols for "documentation, preservation, preparation and distribution of samples for research, education and public outreach" for both current and future collections of astromaterials. Documentation, considered the first stage within the conservation methodology, has evolved many new techniques since curation protocols for the lunar samples were first implemented, and the development of new documentation strategies for current and future astromaterials is beneficial to keeping curation protocols up to date. We have developed and tested a comprehensive non-destructive documentation technique using high-resolution image-based 3D reconstruction and X-ray CT (XCT) data in order to create interactive 3D models of lunar samples that would ultimately be served to both researchers and the public. These data enhance preliminary scientific investigations including targeted sample requests, and also provide a new visual platform for the public to experience and interact with the lunar samples. We intend to serve these data as they are acquired on NASA's Astromaterials Acquisistion and Curation website at http://curator.jsc.nasa.gov/. Providing 3D interior and exterior documentation of astromaterial samples addresses the increasing demands for accessability to data and contemporary techniques for documentation, which can be realized for both current collections as well as future sample return missions.

  18. Application of Lamendin's adult dental aging technique to a diverse skeletal sample.

    PubMed

    Prince, Debra A; Ubelaker, Douglas H

    2002-01-01

    Lamendin et al. (1) proposed a technique to estimate age at death for adults by analyzing single-rooted teeth. They expressed age as a function of two factors: translucency of the tooth root and periodontosis (gingival regression). In their study, they analyzed 306 singled rooted teeth that were extracted at autopsy from 208 individuals of known age at death, all of whom were considered as having a French ancestry. Their sample consisted of 135 males, 73 females, 198 whites, and 10 blacks. The sample ranged in age from 22 to 90 years of age. By using a simple formulae (A = 0.18 x P + 0.42 x T + 25.53, where A = Age in years, P = Periodontosis height x 100/root height, and T = Transparency height x 100/root height), Lamendin et al. were able to estimate age at death with a mean error of +/- 10 years on their working sample and +/- 8.4 years on a forensic control sample. Lamendin found this technique to work well with a French population, but did not test it outside of that sample area. This study tests the accuracy of this adult aging technique on a more diverse skeletal population, the Terry Collection housed at the Smithsonian's National Museum of Natural History. Our sample consists of 400 teeth from 94 black females, 72 white females, 98 black males, and 95 white males, ranging from 25 to 99 years. Lamendin's technique was applied to this sample to test its applicability to a population not of French origin. Providing results from a diverse skeletal population will aid in establishing the validity of this method to be used in forensic cases, its ideal purpose. Our results suggest that Lamendin's method estimates age fairly accurately outside of the French sample yielding a mean error of 8.2 years, standard deviation 6.9 years, and standard error of the mean 0.34 years. In addition, when ancestry and sex are accounted for, the mean errors are reduced for each group (black females, white females, black males, and white males). Lamendin et al. reported an inter-observer error of 9+/-1.8 and 10+/-2 sears from two independent observers. Forty teeth were randomly remeasured from the Terry Collection in order to assess an intra-observer error. From this retest, an intra-observer error of 6.5 years was detected.

  19. Establishment and operation of the National Accident Sampling System (NASS) team within the cities of Ft. Lauderdale/Hollywood, Florida

    NASA Astrophysics Data System (ADS)

    Beddow, B.; Roberts, C.; Rankin, J.; Bloch, A.; Peizer, J.

    1981-01-01

    The National Accident Sampling System (NASS) is described. The study area discussed is one of the original ten sites selected for NASS implementation. In addition to collecting data from the field, the original ten sites address questions of feasibility of the plan, projected results of the data collection effort, and specific operational topics, e.g., team size, sampling requirements, training approaches, quality control procedures, and field techniques. Activities and results of the first three years of the project, for both major tasks (establishment and operation) are addressed. Topics include: study area documentation; team description, function and activities; problems and solutions; and recommendations.

  20. Mixing of thawed coagulation samples prior to testing: Is any technique better than another?

    PubMed

    Lima-Oliveira, Gabriel; Adcock, Dorothy M; Salvagno, Gian Luca; Favaloro, Emmanuel J; Lippi, Giuseppe

    2016-12-01

    Thus study was aimed to investigate whether the mixing technique could influence the results of routine and specialized clotting tests on post-thawed specimens. The sample population consisted of 13 healthy volunteers. Venous blood was collected by evacuated system into three 3.5mL tubes containing 0.109mmol/L buffered sodium citrate. The three blood tubes of each subject were pooled immediately after collection inside a Falcon 15mL tube, then mixed by 6 gentle end-over-end inversions, and centrifuged at 1500g for 15min. Plasma-pool of each subject was then divided in 4 identical aliquots. All aliquots were thawed after 2-day freezing -70°C. Immediately afterwards, the plasma of the four paired aliquots were treated using four different techniques: (a) reference procedure, entailing 6 gentle end-over-end inversions; (b) placing the sample on a blood tube rocker (i.e., rotor mixing) for 5min to induce agitation and mixing; (c) use of a vortex mixer for 20s to induce agitation and mixing; and (d) no mixing. The significance of differences against the reference technique for mixing thawed plasma specimens (i.e., 6 gentle end-over-end inversions) were assessed with paired Student's t-test. The statistical significance was set at p<0.05. As compared to the reference 6-time gentle inversion technique, statistically significant differences were only observed for fibrinogen, and factor VIII in plasma mixed on tube rocker. Some trends were observed in the remaining other cases, but the bias did not achieve statistical significance. We hence suggest that each laboratory should standardize the procedures for mixing of thawed plasma according to a single technique. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  1. Advanced Curation of Current and Future Extraterrestrial Samples

    NASA Technical Reports Server (NTRS)

    Allen, Carlton C.

    2013-01-01

    Curation of extraterrestrial samples is the critical interface between sample return missions and the international research community. Curation includes documentation, preservation, preparation, and distribution of samples. The current collections of extraterrestrial samples include: Lunar rocks / soils collected by the Apollo astronauts Meteorites, including samples of asteroids, the Moon, and Mars "Cosmic dust" (asteroid and comet particles) collected by high-altitude aircraft Solar wind atoms collected by the Genesis spacecraft Comet particles collected by the Stardust spacecraft Interstellar dust collected by the Stardust spacecraft Asteroid particles collected by the Hayabusa spacecraft These samples were formed in environments strikingly different from that on Earth. Terrestrial contamination can destroy much of the scientific significance of many extraterrestrial materials. In order to preserve the research value of these precious samples, contamination must be minimized, understood, and documented. In addition the samples must be preserved - as far as possible - from physical and chemical alteration. In 2011 NASA selected the OSIRIS-REx mission, designed to return samples from the primitive asteroid 1999 RQ36 (Bennu). JAXA will sample C-class asteroid 1999 JU3 with the Hayabusa-2 mission. ESA is considering the near-Earth asteroid sample return mission Marco Polo-R. The Decadal Survey listed the first lander in a Mars sample return campaign as its highest priority flagship-class mission, with sample return from the South Pole-Aitken basin and the surface of a comet among additional top priorities. The latest NASA budget proposal includes a mission to capture a 5-10 m asteroid and return it to the vicinity of the Moon as a target for future sampling. Samples, tools, containers, and contamination witness materials from any of these missions carry unique requirements for acquisition and curation. Some of these requirements represent significant advances over methods currently used. New analytical and screening techniques will increase the value of current sample collections. Improved web-based tools will make information on all samples more accessible to researchers and the public. Advanced curation of current and future extraterrestrial samples includes: Contamination Control - inorganic / organic Temperature of preservation - subfreezing / cryogenic Non-destructive preliminary examination - X-ray tomography / XRF mapping / Raman mapping Microscopic samples - handling / sectioning / transport Special samples - unopened lunar cores Informatics - online catalogs / community-based characterization.

  2. Job Performance as Multivariate Dynamic Criteria: Experience Sampling and Multiway Component Analysis.

    PubMed

    Spain, Seth M; Miner, Andrew G; Kroonenberg, Pieter M; Drasgow, Fritz

    2010-08-06

    Questions about the dynamic processes that drive behavior at work have been the focus of increasing attention in recent years. Models describing behavior at work and research on momentary behavior indicate that substantial variation exists within individuals. This article examines the rationale behind this body of work and explores a method of analyzing momentary work behavior using experience sampling methods. The article also examines a previously unused set of methods for analyzing data produced by experience sampling. These methods are known collectively as multiway component analysis. Two archetypal techniques of multimode factor analysis, the Parallel factor analysis and the Tucker3 models, are used to analyze data from Miner, Glomb, and Hulin's (2010) experience sampling study of work behavior. The efficacy of these techniques for analyzing experience sampling data is discussed as are the substantive multimode component models obtained.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ji, Yanfeng; Hui, Fei; Shi, Yuanyuan

    The conductive atomic force microscope (CAFM) has become an essential tool for the nanoscale electronic characterization of many materials and devices. When studying photoactive samples, the laser used by the CAFM to detect the deflection of the cantilever can generate photocurrents that perturb the current signals collected, leading to unreliable characterization. In metal-coated semiconductor samples, this problem is further aggravated, and large currents above the nanometer range can be observed even without the application of any bias. Here we present the first characterization of the photocurrents introduced by the laser of the CAFM, and we quantify the amount of lightmore » arriving to the surface of the sample. The mechanisms for current collection when placing the CAFM tip on metal-coated photoactive samples are also analyzed in-depth. Finally, we successfully avoided the laser-induced perturbations using a two pass technique: the first scan collects the topography (laser ON) and the second collects the current (laser OFF). We also demonstrate that CAFMs without a laser (using a tuning fork for detecting the deflection of the tip) do not have this problem.« less

  4. Forestry inventory based on multistage sampling with probability proportional to size

    NASA Technical Reports Server (NTRS)

    Lee, D. C. L.; Hernandez, P., Jr.; Shimabukuro, Y. E.

    1983-01-01

    A multistage sampling technique, with probability proportional to size, is developed for a forest volume inventory using remote sensing data. The LANDSAT data, Panchromatic aerial photographs, and field data are collected. Based on age and homogeneity, pine and eucalyptus classes are identified. Selection of tertiary sampling units is made through aerial photographs to minimize field work. The sampling errors for eucalyptus and pine ranged from 8.34 to 21.89 percent and from 7.18 to 8.60 percent, respectively.

  5. Planetary Surface Analysis Using Fast Laser Spectroscopic Techniques: Combined Microscopic Raman, LIBS, and Fluorescence Spectroscopy

    NASA Astrophysics Data System (ADS)

    Blacksberg, J.; Rossman, G. R.; Maruyama, Y.; Charbon, E.

    2011-12-01

    In situ exploration of planetary surfaces has to date required multiple techniques that, when used together, yield important information about their formation histories and evolution. We present a time-resolved laser spectroscopic technique that could potentially collect complementary sets of data providing information on mineral structure, composition, and hydration state. Using a picosecond-scale pulsed laser and a fast time-resolved detector we can simultaneously collect spectra from Raman, Laser Induced Breakdown Spectroscopy (LIBS), and fluorescence emissions that are separated in time due to the unique decay times of each process. The use of a laser with high rep rate (40 KHz) and low pulse energy (1 μJ/pulse) allows us to rapidly collect high signal to noise Raman spectra while minimizing sample damage. Increasing the pulse energy by about an order of magnitude creates a microscopic plasma near the surface and enables the collection of LIBS spectra at an unusually high rep rate and low pulse energy. Simultaneously, broader fluorescence peaks can be detected with lifetimes varying from nanosecond to microsecond. We will present Raman, LIBS, and fluorescence spectra obtained on natural mineral samples such as sulfates, clays, pyroxenes and carbonates that are of interest for Mars mineralogy. We demonstrate this technique using a photocathode-based streak camera detector as well as a newly-developed solid state Single Photon Avalanche Diode (SPAD) sensor array based on Complementary Metal-Oxide Semiconductor (CMOS) technology. We will discuss the impact of system design and detector choice on science return of a potential planetary surface mission, with a specific focus on size, weight, power, and complexity. The research described here was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration (NASA).

  6. A technique for measuring petal gloss, with examples from the Namaqualand flora.

    PubMed

    Whitney, Heather M; Rands, Sean A; Elton, Nick J; Ellis, Allan G

    2012-01-01

    The degree of floral gloss varies between species. However, little is known about this distinctive floral trait, even though it could be a key feature of floral biotic and abiotic interactions. One reason for the absence of knowledge is the lack of a simple, repeatable method of gloss measurement that can be used in the field to study floral gloss. A protocol is described for measuring gloss in petal samples collected in the field, using a glossmeter. Repeatability of the technique is assessed. We demonstrate a simple yet highly accurate and repeatable method that can easily be implemented in the field. We also highlight the huge variety of glossiness found within flowers and between species in a sample of spring-blooming flowers collected in Namaqualand, South Africa. We discuss the potential uses of this method and its applications for furthering studies in plant-pollinator interactions. We also discuss the potential functions of gloss in flowers.

  7. Investigations of calcium spectral lines in laser-induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Ching, Sim Yit; Tariq, Usman; Haider, Zuhaib; Tufail, Kashif; Sabri, Salwanie; Imran, Muhammad; Ali, Jalil

    2017-03-01

    Laser-induced breakdown spectroscopy (LIBS) is a direct and versatile analytical technique that performs the elemental composition analysis based on optical emission produced by laser induced-plasma, with a little or no sample preparation. The performance of the LIBS technique relies on the choice of experimental conditions which must be thoroughly explored and optimized for each application. The main parameters affecting the LIBS performance are the laser energy, laser wavelength, pulse duration, gate delay, geometrical set-up of the focusing and collecting optics. In LIBS quantitative analysis, the gate delay and laser energy are very important parameters that have pronounced impact on the accuracy of the elemental composition information of the materials. The determination of calcium elements in the pelletized samples was investigated and served for the purpose of optimizing the gate delay and laser energy by studying and analyzing the results from emission intensities collected and signal to background ratio (S/B) for the specified wavelengths.

  8. Gastrointestinal parasites among felids inhabiting the Serra dos Órgãos National Park, Rio de Janeiro, Brazil.

    PubMed

    Dib, Laís Verdan; Cronemberger, Cecília; Pereira, Fabiane de Aguiar; Bolais, Paula Forain; Uchôa, Claudia Maria Antunes; Bastos, Otilio Machado Pereira; Amendoeira, Maria Regina Reis; Barbosa, Alynne da Silva

    2018-05-24

    This study aimed to investigate the species of felids that inhabit the Serra dos Órgãos National Park (Parnaso) and gastrointestinal parasites at various stages of their life cycles in the feces of these animals. Between 2013 and 2015, felid feces were collected from trails in Parnaso. The sampling points were georeferenced. A total of 82 fecal samples were processed, of which 79 were collected on the ground, two from captured felids and one from a necropsied animal. All samples underwent coproparasitological techniques. Samples collected from the environment underwent additional trichological analysis. Fur patterns corresponding to Leopardus guttulus, Leopardus pardalis, Leopardus wiedii and Puma yagouaroundi were observed in 32 of the samples collected on the soil. High frequency of potentially parasitic evolving forms (88.6%) was observed in felid feces, particularly eggs of the family Diphyllobothriidae (68.6%). Besides, were also detected, eggs of superfamily Ascaridoidea (42.9%), nematode larvae (28.6%), eggs of order Strongylida (28.6%), Capillaria sp. (8.6%), Trichuris sp. (8.6%), eggs of order Spirurida (2.9%), unsporulated coccidian oocysts (8.6%) and Eimeria sp. (2.9%). Felid feces presented higher frequency of polyparasitism (60%) than monoparasitism (28.6%).

  9. Astromaterials Acquisition and Curation Office (KT) Overview

    NASA Technical Reports Server (NTRS)

    Allen, Carlton

    2014-01-01

    The Astromaterials Acquisition and Curation Office has the unique responsibility to curate NASA's extraterrestrial samples - from past and forthcoming missions - into the indefinite future. Currently, curation includes documentation, preservation, physical security, preparation, and distribution of samples from the Moon, asteroids, comets, the solar wind, and the planet Mars. Each of these sample sets has a unique history and comes from a unique environment. The curation laboratories and procedures developed over 40 years have proven both necessary and sufficient to serve the evolving needs of a worldwide research community. A new generation of sample return missions to destinations across the solar system is being planned and proposed. The curators are developing the tools and techniques to meet the challenges of these new samples. Extraterrestrial samples pose unique curation requirements. These samples were formed and exist under conditions strikingly different from those on the Earth's surface. Terrestrial contamination would destroy much of the scientific significance of extraterrestrial materials. To preserve the research value of these precious samples, contamination must be minimized, understood, and documented. In addition, the samples must be preserved - as far as possible - from physical and chemical alteration. The elaborate curation facilities at JSC were designed and constructed, and have been operated for many years, to keep sample contamination and alteration to a minimum. Currently, JSC curates seven collections of extraterrestrial samples: (a)) Lunar rocks and soils collected by the Apollo astronauts, (b) Meteorites collected on dedicated expeditions to Antarctica, (c) Cosmic dust collected by high-altitude NASA aircraft,t (d) Solar wind atoms collected by the Genesis spacecraft, (e) Comet particles collected by the Stardust spacecraft, (f) Interstellar dust particles collected by the Stardust spacecraft, and (g) Asteroid soil particles collected by the Japan Aerospace Exploration Agency (JAXA) Hayabusa spacecraft Each of these sample sets has a unique history and comes from a unique environment. We have developed specialized laboratories and practices over many years to preserve and protect the samples, not only for current research but for studies that may be carried out in the indefinite future.

  10. Effect of three extraction techniques on submitochondrial particle and Microtox bioassays for airborne particulate matter.

    PubMed

    Torres-Pérez, Mónica I; Jiménez-Velez, Braulio D; Mansilla-Rivera, Imar; Rodríguez-Sierra, Carlos J

    2005-03-01

    The effect that three extraction techniques (e.g., Soxhlet, ultrasound and microwave-assisted extraction) have on the toxicity, as measured by submitochondrial particle (SMP) and Microtox assays, of organic extracts was compared from three sources of airborne particulate matter (APM). The extraction technique influenced the toxicity response of APM extracts and it was dependent on the bioassay method, and APM sample source. APM extracts from microwave-assisted extraction (MAE) were similar or more toxic than the conventional extraction techniques of Soxhlet and ultrasound, thus, providing an alternate extraction method. The microwave extraction technique has the advantage of using less solvent volume, less extraction time, and the capacity to simultaneously extract twelve samples. The ordering of APM toxicity was generally urban dust > diesel dust > PM10 (particles with diameter < 10 microm), thus, reflecting different chemical composition of the samples. This study is the first to report the suitability of two standard in-vitro bioassays for the future toxicological characterization of APM collected from Puerto Rico, with the SMP generally showing better sensitivity to the well-known Microtox bioassay.

  11. Increased recovery of touch DNA evidence using FTA paper compared to conventional collection methods.

    PubMed

    Kirgiz, Irina A; Calloway, Cassandra

    2017-04-01

    Tape lifting and FTA paper scraping methods were directly compared to traditional double swabbing for collecting touch DNA from car steering wheels (n = 70 cars). Touch DNA was collected from the left or right side of each steering wheel (randomized) using two sterile cotton swabs, while the other side was sampled using water-soluble tape or FTA paper cards. DNA was extracted and quantified in duplicate using qPCR. Quantifiable amounts of DNA were detected for 100% of the samples (n = 140) collected independent of the method. However, the DNA collection yield was dependent on the collection method. A statistically significant difference in DNA yield was observed between FTA scraping and double swabbing methods (p = 0.0051), with FTA paper collecting a two-fold higher amount. Statistical analysis showed no significant difference in DNA yields between the double swabbing and tape lifting techniques (p = 0.21). Based on the DNA concentration required for 1 ng input, 47% of the samples collected using FTA paper would be expected to yield a short tandem repeat (STR) profile compared to 30% and 23% using double swabbing or tape, respectively. Further, 55% and 77% of the samples collected using double swabbing or tape, respectively, did not yield a high enough DNA concentration for the 0.5 ng of DNA input recommended for conventional STR kits and would be expected to result in a partial or no profile compared to 35% of the samples collected using FTA paper. STR analysis was conducted for a subset of the higher concentrated samples to confirm that the DNA collected from the steering wheel was from the driver. 32 samples were selected with DNA amounts of at least 1 ng total DNA (100 pg/μl when concentrated if required). A mixed STR profile was observed for 26 samples (88%) and the last driver was the major DNA contributor for 29 samples (94%). For one sample, the last driver was the minor DNA contributor. A full STR profile of the last driver was observed for 21 samples (69%) and a partial profile was observed for nine samples (25%); STR analysis failed for two samples collected using tape (6%). In conclusion, we show that the FTA paper scraping method has the potential to collect higher DNA yields from touch DNA evidence deposited on non-porous surfaces often encountered in criminal cases compared to conventional methods. Copyright © 2017 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  12. Proteomic Characterization of Dermal Interstitial Fluid Extracted Using a Novel Microneedle-Assisted Technique.

    PubMed

    Tran, Bao Quoc; Miller, Philip R; Taylor, Robert M; Boyd, Gabrielle; Mach, Phillip M; Rosenzweig, C Nicole; Baca, Justin T; Polsky, Ronen; Glaros, Trevor

    2018-01-05

    As wearable fitness devices have gained commercial acceptance, interest in real-time monitoring of an individual's physiological status using noninvasive techniques has grown. Microneedles have been proposed as a minimally invasive technique for sampling the dermal interstitial fluid (ISF) for clinical monitoring and diagnosis, but little is known about its composition. In this study, a novel microneedle array was used to collect dermal ISF from three healthy human donors and compared with matching serum and plasma samples. Using a shotgun quantitative proteomic approach, 407 proteins were quantified with at least one unique peptide, and of those, 135 proteins were differently expressed at least 2-fold. Collectively, these proteins tended to originate from the cytoplasm, membrane bound vesicles, and extracellular vesicular exosomes. Proteomic analysis confirmed previously published work that indicates that ISF is highly similar to both plasma and serum. In this study, less than one percent of proteins were uniquely identified in ISF. Taken together, ISF could serve as a minimally invasive alternative for blood-derived fluids with potential for real-time monitoring applications.

  13. Determination of oestrous cycle of the rats by direct examination: how reliable?

    PubMed

    Yener, T; Turkkani Tunc, A; Aslan, H; Aytan, H; Cantug Caliskan, A

    2007-02-01

    For determination of the oestrous cycle in rats classical Papanicolaou technique has long been used successfully. Instead of using many stains in Papanicolaou, staining the vaginal secretions with only methylene blue has also been defined. Recently a new technique in which vaginal samples are directly examined under light microscope has been introduced. The aim of this study was to assess the reliability of this new technique by comparing it with the classical staining techniques. From 20 Wistar rats 60 vaginal samples were collected with a micropipette, three from each. Briefly, the vagina was flushed two to three times then the fluid was placed onto a glass slide. The fluid was equally distributed onto three glass slides. The glass slides were coded. Two samples were stained with Papanicolaou and methylene blue while the other one was examined directly. Determination of the phases of the oestrous cycle was made by the same histologist who was blinded to the groups and coding system. After determination of the oestrous phase in all samples, the results were compared and it was found that the results were matching. In conclusion, the same results can be obtained with the direct examination technique and this technique is reliable, so there is no need to use relatively time-consuming, less practical and more expensive techniques such as Papanicolaou or methylene blue.

  14. The signature-based radiation-scanning approach to standoff detection of improvised explosive devices.

    PubMed

    Brewer, R L; Dunn, W L; Heider, S; Matthew, C; Yang, X

    2012-07-01

    The signature-based radiation-scanning technique for detection of improvised explosive devices is described. The technique seeks to detect nitrogen-rich chemical explosives present in a target. The technology compares a set of "signatures" obtained from a test target to a collection of "templates", sets of signatures for a target that contain an explosive in a specific configuration. Interrogation of nitrogen-rich fertilizer samples, which serve as surrogates for explosives, is shown experimentally to be able to discriminate samples of 3.8L and larger. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Forensic collection of trace chemicals from diverse surfaces with strippable coatings.

    PubMed

    Jakubowski, Michael J; Beltis, Kevin J; Drennan, Paul M; Pindzola, Bradford A

    2013-11-07

    Surface sampling for chemical analysis plays a vital role in environmental monitoring, industrial hygiene, homeland security and forensics. The standard surface sampling tool, a simple cotton gauze pad, is failing to meet the needs of the community as analytical techniques become more sensitive and the variety of analytes increases. In previous work, we demonstrated the efficacy of non-destructive, conformal, spray-on strippable coatings for chemical collection from simple glass surfaces. Here we expand that work by presenting chemical collection at a low spiking level (0.1 g m(-2)) from a diverse array of common surfaces - painted metal, engineering plastics, painted wallboard and concrete - using strippable coatings. The collection efficiency of the strippable coatings is compared to and far exceeds gauze pads. Collection from concrete, a particular challenge for wipes like gauze, averaged 73% over eight chemically diverse compounds for the strippable coatings whereas gauze averaged 10%.

  16. Direct typing of Canine parvovirus (CPV) from infected dog faeces by rapid mini sequencing technique.

    PubMed

    V, Pavana Jyothi; S, Akila; Selvan, Malini K; Naidu, Hariprasad; Raghunathan, Shwethaa; Kota, Sathish; Sundaram, R C Raja; Rana, Samir Kumar; Raj, G Dhinakar; Srinivasan, V A; Mohana Subramanian, B

    2016-12-01

    Canine parvovirus (CPV) is a non-enveloped single stranded DNA virus with an icosahedral capsid. Mini-sequencing based CPV typing was developed earlier to detect and differentiate all the CPV types and FPV in a single reaction. This technique was further evaluated in the present study by performing the mini-sequencing directly from fecal samples which avoided tedious virus isolation steps by cell culture system. Fecal swab samples were collected from 84 dogs with enteritis symptoms, suggestive of parvoviral infection from different locations across India. Seventy six of these samples were positive by PCR; the subsequent mini-sequencing reaction typed 74 of them as type 2a virus, and 2 samples as type 2b. Additionally, 25 of the positive samples were typed by cycle sequencing of PCR products. Direct CPV typing from fecal samples using mini-sequencing showed 100% correlation with CPV typing by cycle sequencing. Moreover, CPV typing was achieved by mini-sequencing even with faintly positive PCR amplicons which was not possible by cycle sequencing. Therefore, the mini-sequencing technique is recommended for regular epidemiological follow up of CPV types, since the technique is rapid, highly sensitive and high capacity method for CPV typing. Copyright © 2016. Published by Elsevier B.V.

  17. Detection techniques using multispectral data to index soil erosional status

    NASA Technical Reports Server (NTRS)

    Pelletier, R. E.

    1988-01-01

    Indexing techniques that can be used to detect soil erosion utilizing the known band widths of the Landsat MSS and TM sensors are identified. The indexing techniques focus on iron oxides, clays, and organic matter as properties revealing soil erosional status. For data aquisition, a Collins visible and infrared intelligent spectrometer was used to collect data from 0.4-24 microns. Pressed polytetrafluorethylene was used as the reflectance standard and was aquired at the same time that the sample data were aquired.

  18. A collection of flow visualization techniques used in the Aerodynamic Research Branch

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Theoretical and experimental research on unsteady aerodynamic flows is discussed. Complex flow fields that involve separations, vortex interactions, and transonic flow effects were investigated. Flow visualization techniques are used to obtain a global picture of the flow phenomena before detailed quantitative studies are undertaken. A wide variety of methods are used to visualize fluid flow and a sampling of these methods is presented. It is emphasized that the visualization technique is a thorough quantitative analysis and subsequent physical understanding of these flow fields.

  19. The Effect of Reactive atypia/Inflammation on the Laser-Induced Fluorescence Diagnosis of Non-dysplastic Barrett’s Esophagus

    PubMed Central

    Panjehpour, Masoud; Overholt, Bergein F.; Vo-Dinh, Tuan; Coppola, Domenico

    2012-01-01

    Background and Objectives Differential Normalized Fluorescence (DNF) technique has been used to distinguish high-grade dysplasia from non-dysplastic Barrett’s esophagus. This technology may assist gastroenterologists in targeting biopsies, reducing the number of biopsies using the standard protocol. In the presence of reactive atypia/inflammation, it becomes difficult for the pathologist to differentiate non-dysplastic Barrett’s esophagus from Barrett’s esophagus with low grade dysplasia. Before DNF technique may be used to guide target biopsies, it is critical to know whether reactive atypia/inflammation in non-dysplastic Barrett’s may result in false positives. This study was conducted to determine whether DNF technique is adversely affected by the presence of reactive atypia/inflammation in non-dysplastic Barrett’s esophagus resulting in false positives. Study Design/Materials and Methods 410-nm laser light was used to induce autofluorescence of Barrett's mucosa in 49 patients. The clinical study included 37 males and 12 females. This was a blinded retrospective data analysis study. A total of 303 spectra were collected and matched to non-dysplastic Barrett’s biopsy results. 175 spectra were collected from areas with a pathology of non-dysplastic Barrett’s esophagus with reactive atypia/inflammation. 128 spectra were collected from areas with non-dysplastic Barrett’s esophagus without reactive changes/ inflammation. The spectra were analyzed using the DNF Index at 480 nm and classified as positive or negative using the threshold of −0.75 × 10−03 . Results Using DNF technique, 92.6% of non-dysplastic samples with reactive atypia/inflammation were classified correctly (162/175). 92.2 % of non-dysplastic samples without reactive atypia/inflammation were classified correctly (118/128). Comparing the ratios of false positives among the two sample groups, there was not a statistically significant difference between the two groups. Conclusion Using Differential Normalized Fluorescence technique for classification of non-dysplastic Barrett’s mucosa doesn’t result in false positive readings due to reactive atypia/inflammation. Target biopsies guided by DNF technique may drastically reduce the number of pinch biopsies using the standard biopsy protocol. PMID:22535652

  20. Antimicrobial activity of honey of stingless bees, tiúba (Melipona fasciculata) and jandaira (Melipona subnitida) compared to the strains of Staphylococcus aureus, Escherichia coli and Pseudomonas aeruginosa

    NASA Astrophysics Data System (ADS)

    Tenório, Eleuza Gomes; de Jesus, Natália Rocha; Nascimento, Adenilde Ribeiro; Teles, Amanda Mara

    2015-12-01

    This study aimed to investigate the antimicrobial activity of honeys of stingless bees produced in Maranhão, tiúba (Melipona fasciculata) and jandaira (Melipona subnitida), opposite the strains of pathogenic bacteria, namely, Staphylococcus aureus, Escherichia coli and Pseudomonas aeruginosa. The honey samples were collected from different regions of Maranhão. Of the 17 samples collected, twelve samples were honey M. fasciculata and five were honey M. subnitida. We used the Kirby-Bauer method, and the technique of agar disk diffusion through the extent of inhibition in milimetros. Results were negative for all samples from M. fasciculata. However, the tests for M. subnitida demonstrated bacteriostatic halos ranging from 12 to 32,6mm.

  1. Carbon Nanostructure of Diesel Soot Particles Emitted from 2 and 4 Stroke Marine Engines Burning Different Fuels.

    PubMed

    Lee, Won-Ju; Park, Seul-Hyun; Jang, Se-Hyun; Kim, Hwajin; Choi, Sung Kuk; Cho, Kwon-Hae; Cho, Ik-Soon; Lee, Sang-Min; Choi, Jae-Hyuk

    2018-03-01

    Diesel soot particles were sampled from 2-stroke and 4-stroke engines that burned two different fuels (Bunker A and C, respectively), and the effects of the engine and fuel types on the structural characteristics of the soot particle were analyzed. The carbon nanostructures of the sampled particles were characterized using various techniques. The results showed that the soot sample collected from the 4-stroke engine, which burned Bunker C, has a higher degree of order of the carbon nanostructure than the sample collected from the 2-stroke engine, which burned Bunker A. Furthermore, the difference in the exhaust gas temperatures originating from the different engine and fuel types can affect the nanostructure of the soot emitted from marine diesel engines.

  2. The Effective Management of Primary Schools in Ekiti State, Nigeria: An Analytical Assessment

    ERIC Educational Resources Information Center

    Adeyemi, T. O.

    2009-01-01

    This study investigated the management of education in primary schools in Ekiti State, Nigeria. As a correlational research, the study population comprised all the 694 primary schools in the State. Out of this, a sample of 320 schools was selected through the stratified random sampling technique. Two instruments were used to collect data for the…

  3. An Investigation on Balance between Professional and Personal Work of Women Teachers

    ERIC Educational Resources Information Center

    Priya, J. Johnsi

    2017-01-01

    The present study aims to examine the work-life balance of women teachers in Chennai city. In this normative survey study, 100 women teachers were selected as sample by using convenient sampling technique. The data were collected from 100 women teachers who are working in eight Higher Secondary Schools at chennai city using the Work-life Balance…

  4. Irregular Breakfast Eating and Associated Health Behaviors: A Pilot Study among College Students

    ERIC Educational Resources Information Center

    Thiagarajah, Krisha; Torabi, Mohammad R.

    2009-01-01

    The purpose of this study was to examine prevalence of eating breakfast and associated health compromising behaviors. This study utilized a cross-sectional survey methodology. A purposive cluster sampling technique was utilized to collect data from a representative sample of college students in a Midwestern university in the U.S. A total of 1,257…

  5. Detection of and Monitoring for Aedes albopictus (Diptera: Culicidae) in Suburban and Sylvatic Habitats in North Central Florida using Four Sampling Techniques

    USDA-ARS?s Scientific Manuscript database

    A sampling study using a BG-Sentinel trap baited with CO2, a gravid trap baited with an oak-pine infusion, a human subject and a vegetative aspirator was conducted to compare their reliability at detecting Ae. albopictus in suburban and sylvatic habitats. We collected 73,849 mosquitoes, representin...

  6. Wavelet-Based Interpolation and Representation of Non-Uniformly Sampled Spacecraft Mission Data

    NASA Technical Reports Server (NTRS)

    Bose, Tamal

    2000-01-01

    A well-documented problem in the analysis of data collected by spacecraft instruments is the need for an accurate, efficient representation of the data set. The data may suffer from several problems, including additive noise, data dropouts, an irregularly-spaced sampling grid, and time-delayed sampling. These data irregularities render most traditional signal processing techniques unusable, and thus the data must be interpolated onto an even grid before scientific analysis techniques can be applied. In addition, the extremely large volume of data collected by scientific instrumentation presents many challenging problems in the area of compression, visualization, and analysis. Therefore, a representation of the data is needed which provides a structure which is conducive to these applications. Wavelet representations of data have already been shown to possess excellent characteristics for compression, data analysis, and imaging. The main goal of this project is to develop a new adaptive filtering algorithm for image restoration and compression. The algorithm should have low computational complexity and a fast convergence rate. This will make the algorithm suitable for real-time applications. The algorithm should be able to remove additive noise and reconstruct lost data samples from images.

  7. Maps showing mines, quarries, and prospects, with analyses of samples, Gee Creek Wilderness, Polk and Monroe counties, Tennessee

    USGS Publications Warehouse

    Gazdik, Gertrude C.; Behum, Paul T.

    1983-01-01

    During the recent U.S. Bureau of Mines field investigation, 21 samples were collected (fig. 2) and were submitted to the Bureau's Reno Metallurgy Research Center, Reno, Nev., for analysis. All samples were tested for 40 elements by semiquantitative spectrographic analyses. Additional testing by atomic absorption, neutron activation, and wet chemical techniques was performed for selected elements on some samples. Two shale samples were submitted to the Bureau of Mines, Tuscaloosa Metallurgy Research Center, Tuscaloosa, Ala., for the evaluation of ceramic properties. 

  8. Biology Procedural Knowledge at Eleventh Grade of Senior High School in West Lampung Based on Curriculum

    NASA Astrophysics Data System (ADS)

    Sari, T. M.; Paidi; Mercuriani, I. S.

    2018-03-01

    This study was aim to determine Biology procedural knowledge of senior high school in West Lampung based on curriculum at 11th grade in even semester. This research was descriptive research. The population was all students of senior high school in West Lampung. The sampling technique in this research used purposive sampling technique, so the researcher obtained 3 schools using K13 and 3 schools using KTSP. Data collecting technique used instrument test. Data analysis technique used U-Mann Whitney test. The result showed that p=0.028 (p<0.05), so there was significant differences between school using K13 and KTSP. The procedural knowledge of schools which using K13 is higher than school which using KTSP, with the mean score K13=4.35 and KTSP=4.00

  9. Concentration and separation of biological organisms by ultrafiltration and dielectrophoresis

    DOEpatents

    Simmons, Blake A.; Hill, Vincent R.; Fintschenko, Yolanda; Cummings, Eric B.

    2010-10-12

    Disclosed is a method for monitoring sources of public water supply for a variety of pathogens by using a combination of ultrafiltration techniques together dielectrophoretic separation techniques. Because water-borne pathogens, whether present due to "natural" contamination or intentional introduction, would likely be present in drinking water at low concentrations when samples are collected for monitoring or outbreak investigations, an approach is needed to quickly and efficiently concentrate and separate particles such as viruses, bacteria, and parasites in large volumes of water (e.g., 100 L or more) while simultaneously reducing the sample volume to levels sufficient for detecting low concentrations of microbes (e.g., <10 mL). The technique is also designed to screen the separated microbes based on specific conductivity and size.

  10. Measuring the radium quartet (228Ra, 226Ra, 224Ra, 223Ra) in seawater samples using gamma spectrometry.

    PubMed

    van Beek, P; Souhaut, M; Reyss, J-L

    2010-07-01

    Radium isotopes are widely used in marine studies (eg. to trace water masses, to quantify mixing processes or to study submarine groundwater discharge). While 228Ra and 226Ra are usually measured using gamma spectrometry, short-lived Ra isotopes (224Ra and 223Ra) are usually measured using a Radium Delayed Coincidence Counter (RaDeCC). Here we show that the four radium isotopes can be analyzed using gamma spectrometry. We report 226Ra, 228Ra, 224Ra, 223Ra activities measured using low-background gamma spectrometry in standard samples, in water samples collected in the vicinity of our laboratory (La Palme and Vaccarès lagoons, France) but also in seawater samples collected in the plume of the Amazon river, off French Guyana (AMANDES project). The 223Ra and 224Ra activities determined in these samples using gamma spectrometry were compared to the activities determined using RaDeCC. Activities determined using the two techniques are in good agreement. Uncertainties associated with the 224Ra activities are similar for the two techniques. RaDeCC is more sensitive for the detection of low 223Ra activities. Gamma spectrometry thus constitutes an alternate method for the determination of short-lived Ra isotopes. 2009 Elsevier Ltd. All rights reserved.

  11. Endoscopic Ultrasound-guided Specimen Collection and Evaluation Techniques Affect Diagnostic Accuracy.

    PubMed

    Bang, Ji Young; Navaneethan, Udayakumar; Hasan, Muhammad K; Hawes, Robert; Varadarajulu, Shyam

    2018-03-11

    Outcomes of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) evaluation vary with technique, needles, and methods of specimen evaluation. We performed a direct comparison of diagnostic yields of EUS-FNA samples collected using different gauge needles (22- vs 25-gauge), with or without suction. We performed a randomized controlled study of 352 patients with suspected pancreatic masses, referred for EUS-FNA at a tertiary referral center. Patients were randomly assigned to 22-gauge needles with or without suction or 25-gauge needles with or without suction. Specimens were evaluated offsite by cell block and rapid onsite cytologic evaluation (ROSE). Final diagnoses were made based on histologic analyses or 12-month follow-up evaluations. The primary outcome was diagnostic adequacy of cell blocks. Secondary outcomes were operating characteristics of ROSE and EUS-FNA, number of passes required for accurate onsite diagnosis, and amount of blood in specimens. The final diagnoses were malignancy (81.5% of patients) and benign disease (17.0% of patients); 1.4% of patients were lost during follow up. Cell block, ROSE, and EUS-FNA led to diagnostic accuracies of 71.9%, 95.5%, and 96.6%, respectively. A 22-gauge needle with suction was associated with more passes for adequate onsite diagnosis (P = .003) and specimens contained more blood (P = .01). Diagnostic accuracy of specimens collected by transduodenal EUS-FNA was lower with 22-gauge needles with suction compared to other techniques (P = .004). In a randomized trial of patients undergoing EUS-FNA for pancreatic masses, samples collected with 22-gauge vs 25-gauge needles performed equally well for offsite specimen evaluation. Use of suction appears to increase number of passes needed and specimen bloodiness. Specimen collection techniques should be individualized based on method of evaluation. ClinicalTrials.gov no: NCT02424838. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  12. 77 FR 51818 - Agency Information Collection Activities; Application and Approval To Manipulate, Examine, Sample...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-27

    ... automated, electronic, mechanical, or other technological techniques or other forms of information. Title... year for continuous or repetitive manipulation. CBP Form 3499 is provided for by 19 CFR 19.8 and is...

  13. 10 CFR 51.22 - Criterion for categorical exclusion; identification of licensing and regulatory actions eligible...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... United States, to fund scholarships, fellowships, and stipends for the study of science, engineering, or...-harmful techniques such as taking water or soil samples or collecting non-protected species of flora and...

  14. 10 CFR 51.22 - Criterion for categorical exclusion; identification of licensing and regulatory actions eligible...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... United States, to fund scholarships, fellowships, and stipends for the study of science, engineering, or...-harmful techniques such as taking water or soil samples or collecting non-protected species of flora and...

  15. 10 CFR 51.22 - Criterion for categorical exclusion; identification of licensing and regulatory actions eligible...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... United States, to fund scholarships, fellowships, and stipends for the study of science, engineering, or...-harmful techniques such as taking water or soil samples or collecting non-protected species of flora and...

  16. 10 CFR 51.22 - Criterion for categorical exclusion; identification of licensing and regulatory actions eligible...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... United States, to fund scholarships, fellowships, and stipends for the study of science, engineering, or...-harmful techniques such as taking water or soil samples or collecting non-protected species of flora and...

  17. Accuracy of a new clean-catch technique for diagnosis of urinary tract infection in infants younger than 90 days of age

    PubMed Central

    Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo

    2015-01-01

    OBJECTIVE: To evaluate the accuracy of diagnosing urinary tract infections using a new, recently described, standardized clean-catch collection technique. METHODS: Cross-sectional study of infants <90 days old admitted due to fever without a source, with two matched samples of urine obtained using two different methods: clean-catch standardized stimulation technique and bladder catheterization. RESULTS: Sixty paired urine cultures were obtained. The median age was 44-days-old. Seventeen percent were male infants. Clean-catch technique sensitivity was 97% (95% CI 82% to 100%) and specificity was 89% (95% CI 65% to 98%). The contamination rate of clean-catch samples was lower (5%) than the contamination rate of catheter specimens (8%). CONCLUSIONS: The sensitivity and specificity of urine cultures obtained using the clean-catch method through the new technique were accurate and the contamination rate was low. These results suggest that this technique is a valuable, alternative method for urinary tract infection diagnosis. PMID:26435675

  18. 3D-Laser-Scanning Technique Applied to Bulk Density Measurements of Apollo Lunar Samples

    NASA Technical Reports Server (NTRS)

    Macke, R. J.; Kent, J. J.; Kiefer, W. S.; Britt, D. T.

    2015-01-01

    In order to better interpret gravimetric data from orbiters such as GRAIL and LRO to understand the subsurface composition and structure of the lunar crust, it is import to have a reliable database of the density and porosity of lunar materials. To this end, we have been surveying these physical properties in both lunar meteorites and Apollo lunar samples. To measure porosity, both grain density and bulk density are required. For bulk density, our group has historically utilized sub-mm bead immersion techniques extensively, though several factors have made this technique problematic for our work with Apollo samples. Samples allocated for measurement are often smaller than optimal for the technique, leading to large error bars. Also, for some samples we were required to use pure alumina beads instead of our usual glass beads. The alumina beads were subject to undesirable static effects, producing unreliable results. Other investigators have tested the use of 3d laser scanners on meteorites for measuring bulk volumes. Early work, though promising, was plagued with difficulties including poor response on dark or reflective surfaces, difficulty reproducing sharp edges, and large processing time for producing shape models. Due to progress in technology, however, laser scanners have improved considerably in recent years. We tested this technique on 27 lunar samples in the Apollo collection using a scanner at NASA Johnson Space Center. We found it to be reliable and more precise than beads, with the added benefit that it involves no direct contact with the sample, enabling the study of particularly friable samples for which bead immersion is not possible

  19. Source apportion of atmospheric particulate matter: a joint Eulerian/Lagrangian approach.

    PubMed

    Riccio, A; Chianese, E; Agrillo, G; Esposito, C; Ferrara, L; Tirimberio, G

    2014-12-01

    PM2.5 samples were collected during an annual monitoring campaign (January 2012-January 2013) in the urban area of Naples, one of the major cities in Southern Italy. Samples were collected by means of a standard gravimetric sampler (Tecora Echo model) and characterized from a chemical point of view by ion chromatography. As a result, 143 samples together with their ionic composition have been collected. We extend traditional source apportionment techniques, usually based on multivariate factor analysis, interpreting the chemical analysis results within a Lagrangian framework. The Hybrid Single-Particle Lagrangian Integrated Trajectory Model (HYSPLIT) model was used, providing linkages to the source regions in the upwind areas. Results were analyzed in order to quantify the relative weight of different source types/areas. Model results suggested that PM concentrations are strongly affected not only by local emissions but also by transboundary emissions, especially from the Eastern and Northern European countries and African Saharan dust episodes.

  20. Detection of Papaverine for the Possible Identification of Illicit Opium Cultivation.

    PubMed

    Mirsafavi, Rustin Y; Lai, Kristine; Kline, Neal D; Fountain, Augustus W; Meinhart, Carl D; Moskovits, Martin

    2017-02-07

    Papaverine is a non-narcotic alkaloid found endemically and uniquely in the latex of the opium poppy. It is normally refined out of the opioids that the latex is typically collected for, hence its presence in a sample is strong prima facie evidence that the carrier from whom the sample was collected is implicated in the mass cultivation of poppies or the collection and handling of their latex. We describe an analysis technique combining surface-enhanced Raman spectroscopy (SERS) with microfluidics for detecting papaverine at low concentrations and show that its SERS spectrum has unique spectroscopic features that allows its detection at low concentrations among typical opioids. The analysis requires approximately 2.5 min from sample loading to results, which is compatible with field use. The weak acid properties of papaverine hydrochloride were investigated, and Raman bands belonging to the protonated and unprotonated forms of the isoquinoline ring of papaverine were identified.

  1. Meteorites and Microbes: Meteorite Collection and Ice Sampling at Patriot Hills, Thiel Mountains, and South Pole, Antarctica

    NASA Technical Reports Server (NTRS)

    Sipiera, Paul P.; Hoover, Richard B.; Rose, M. Franklin (Technical Monitor)

    2000-01-01

    During the Antarctica 2000 Expedition, sponsored by the Planetary Studies Foundation, meteorites and ice microbiota were collected from the Patriot Hills, and Thiel Mountains of Antarctica and snow samples were at the South Pole. Psychrophilic and psychrotrophic microbiota were obtained from blue ice, cryoconite and ice-bubble systems. Twenty frozen meteorites were collected using aseptic techniques from the blue ice fields near the Moulton Escarpment of the Thiel Mountains (85 S, 94 W) and from the Morris Moraine of the Patriot Hills (80 S, 81 W) Ellsworth Mountains. These ice and meteorite samples are of potential significance to Astrobiology. They may help refine chemical and morphological biomarkers and refine characteristics of microbial life in one of the harshest environments on Earth. We discuss the Antarctica 2000 Expedition and provide preliminary results of the investigation of the meteorites and ice microbiota recovered.

  2. Morphological diversity of Trichuris spp. eggs observed during an anthelminthic drug trial in Yunnan, China, and relative performance of parasitologic diagnostic tools.

    PubMed

    Steinmann, Peter; Rinaldi, Laura; Cringoli, Giuseppe; Du, Zun-Wei; Marti, Hanspeter; Jiang, Jin-Yong; Zhou, Hui; Zhou, Xiao-Nong; Utzinger, Jürg

    2015-01-01

    The presence of large Trichuris spp. eggs in human faecal samples is occasionally reported. Such eggs have been described as variant Trichuris trichiura or Trichuris vulpis eggs. Within the frame of a randomised controlled trial, faecal samples collected from 115 Bulang individuals from Yunnan, People's Republic of China were subjected to the Kato-Katz technique (fresh stool samples) and the FLOTAC and ether-concentration techniques (sodium acetate-acetic acid-formalin (SAF)-fixed stool samples). Large Trichuris spp. eggs were noted in faecal samples with a prevalence of 6.1% before and 21.7% after anthelminthic drug administration. The observed prevalence of standard-sized T. trichiura eggs was reduced from 93.0% to 87.0% after treatment. Considerably more cases of large Trichuris spp. eggs and slightly more cases with normal-sized T. trichiura eggs were identified by FLOTAC compared to the ether-concentration technique. No large Trichuris spp. eggs were observed on the Kato-Katz thick smears. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Sampling free energy surfaces as slices by combining umbrella sampling and metadynamics.

    PubMed

    Awasthi, Shalini; Kapil, Venkat; Nair, Nisanth N

    2016-06-15

    Metadynamics (MTD) is a very powerful technique to sample high-dimensional free energy landscapes, and due to its self-guiding property, the method has been successful in studying complex reactions and conformational changes. MTD sampling is based on filling the free energy basins by biasing potentials and thus for cases with flat, broad, and unbound free energy wells, the computational time to sample them becomes very large. To alleviate this problem, we combine the standard Umbrella Sampling (US) technique with MTD to sample orthogonal collective variables (CVs) in a simultaneous way. Within this scheme, we construct the equilibrium distribution of CVs from biased distributions obtained from independent MTD simulations with umbrella potentials. Reweighting is carried out by a procedure that combines US reweighting and Tiwary-Parrinello MTD reweighting within the Weighted Histogram Analysis Method (WHAM). The approach is ideal for a controlled sampling of a CV in a MTD simulation, making it computationally efficient in sampling flat, broad, and unbound free energy surfaces. This technique also allows for a distributed sampling of a high-dimensional free energy surface, further increasing the computational efficiency in sampling. We demonstrate the application of this technique in sampling high-dimensional surface for various chemical reactions using ab initio and QM/MM hybrid molecular dynamics simulations. Further, to carry out MTD bias reweighting for computing forward reaction barriers in ab initio or QM/MM simulations, we propose a computationally affordable approach that does not require recrossing trajectories. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  4. Molecular dynamics based enhanced sampling of collective variables with very large time steps.

    PubMed

    Chen, Pei-Yang; Tuckerman, Mark E

    2018-01-14

    Enhanced sampling techniques that target a set of collective variables and that use molecular dynamics as the driving engine have seen widespread application in the computational molecular sciences as a means to explore the free-energy landscapes of complex systems. The use of molecular dynamics as the fundamental driver of the sampling requires the introduction of a time step whose magnitude is limited by the fastest motions in a system. While standard multiple time-stepping methods allow larger time steps to be employed for the slower and computationally more expensive forces, the maximum achievable increase in time step is limited by resonance phenomena, which inextricably couple fast and slow motions. Recently, we introduced deterministic and stochastic resonance-free multiple time step algorithms for molecular dynamics that solve this resonance problem and allow ten- to twenty-fold gains in the large time step compared to standard multiple time step algorithms [P. Minary et al., Phys. Rev. Lett. 93, 150201 (2004); B. Leimkuhler et al., Mol. Phys. 111, 3579-3594 (2013)]. These methods are based on the imposition of isokinetic constraints that couple the physical system to Nosé-Hoover chains or Nosé-Hoover Langevin schemes. In this paper, we show how to adapt these methods for collective variable-based enhanced sampling techniques, specifically adiabatic free-energy dynamics/temperature-accelerated molecular dynamics, unified free-energy dynamics, and by extension, metadynamics, thus allowing simulations employing these methods to employ similarly very large time steps. The combination of resonance-free multiple time step integrators with free-energy-based enhanced sampling significantly improves the efficiency of conformational exploration.

  5. Molecular dynamics based enhanced sampling of collective variables with very large time steps

    NASA Astrophysics Data System (ADS)

    Chen, Pei-Yang; Tuckerman, Mark E.

    2018-01-01

    Enhanced sampling techniques that target a set of collective variables and that use molecular dynamics as the driving engine have seen widespread application in the computational molecular sciences as a means to explore the free-energy landscapes of complex systems. The use of molecular dynamics as the fundamental driver of the sampling requires the introduction of a time step whose magnitude is limited by the fastest motions in a system. While standard multiple time-stepping methods allow larger time steps to be employed for the slower and computationally more expensive forces, the maximum achievable increase in time step is limited by resonance phenomena, which inextricably couple fast and slow motions. Recently, we introduced deterministic and stochastic resonance-free multiple time step algorithms for molecular dynamics that solve this resonance problem and allow ten- to twenty-fold gains in the large time step compared to standard multiple time step algorithms [P. Minary et al., Phys. Rev. Lett. 93, 150201 (2004); B. Leimkuhler et al., Mol. Phys. 111, 3579-3594 (2013)]. These methods are based on the imposition of isokinetic constraints that couple the physical system to Nosé-Hoover chains or Nosé-Hoover Langevin schemes. In this paper, we show how to adapt these methods for collective variable-based enhanced sampling techniques, specifically adiabatic free-energy dynamics/temperature-accelerated molecular dynamics, unified free-energy dynamics, and by extension, metadynamics, thus allowing simulations employing these methods to employ similarly very large time steps. The combination of resonance-free multiple time step integrators with free-energy-based enhanced sampling significantly improves the efficiency of conformational exploration.

  6. Comparison of the detection of periodontal pathogens in bacteraemia after tooth brushing by culture and molecular techniques.

    PubMed

    Marín, M-J; Figuero, E; González, I; O'Connor, A; Diz, P; Álvarez, M; Herrera, D; Sanz, M

    2016-05-01

    The prevalence and amounts of periodontal pathogens detected in bacteraemia samples after tooth brushing-induced by means of four diagnostic technique, three based on culture and one in a molecular-based technique, have been compared in this study. Blood samples were collected from thirty-six subjects with different periodontal status (17 were healthy, 10 with gingivitis and 9 with periodontitis) at baseline and 2 minutes after tooth brushing. Each sample was analyzed by three culture-based methods [direct anaerobic culturing (DAC), hemo-culture (BACTEC), and lysis-centrifugation (LC)] and one molecular-based technique [quantitative polymerase chain reaction (qPCR)]. With culture any bacterial isolate was detected and quantified, while with qPCR only Porphyromonas gingivalis and Aggregatibacter actinomycetemcomitans were detected and quantified. Descriptive analyses, ANOVA and Chi-squared tests, were performed. Neither BACTEC nor qPCR detected any type of bacteria in the blood samples. Only LC (2.7%) and DAC (8.3%) detected bacteraemia, although not in the same patients. Fusobacterium nucleatum was the most frequently detected bacterial species. The disparity in the results when the same samples were analyzed with four different microbiological detection methods highlights the need for a proper validation of the methodology to detect periodontal pathogens in bacteraemia samples, mainly when the presence of periodontal pathogens in blood samples after tooth brushing was very seldom.

  7. A variational conformational dynamics approach to the selection of collective variables in metadynamics.

    PubMed

    McCarty, James; Parrinello, Michele

    2017-11-28

    In this paper, we combine two powerful computational techniques, well-tempered metadynamics and time-lagged independent component analysis. The aim is to develop a new tool for studying rare events and exploring complex free energy landscapes. Metadynamics is a well-established and widely used enhanced sampling method whose efficiency depends on an appropriate choice of collective variables. Often the initial choice is not optimal leading to slow convergence. However by analyzing the dynamics generated in one such run with a time-lagged independent component analysis and the techniques recently developed in the area of conformational dynamics, we obtain much more efficient collective variables that are also better capable of illuminating the physics of the system. We demonstrate the power of this approach in two paradigmatic examples.

  8. A variational conformational dynamics approach to the selection of collective variables in metadynamics

    NASA Astrophysics Data System (ADS)

    McCarty, James; Parrinello, Michele

    2017-11-01

    In this paper, we combine two powerful computational techniques, well-tempered metadynamics and time-lagged independent component analysis. The aim is to develop a new tool for studying rare events and exploring complex free energy landscapes. Metadynamics is a well-established and widely used enhanced sampling method whose efficiency depends on an appropriate choice of collective variables. Often the initial choice is not optimal leading to slow convergence. However by analyzing the dynamics generated in one such run with a time-lagged independent component analysis and the techniques recently developed in the area of conformational dynamics, we obtain much more efficient collective variables that are also better capable of illuminating the physics of the system. We demonstrate the power of this approach in two paradigmatic examples.

  9. Determination of the elemental composition of aerosol samples in the working environment of a secondary lead smelting company in Nigeria using EDXRF technique

    NASA Astrophysics Data System (ADS)

    Obiajunwa, E. I.; Johnson-Fatokun, F. O.; Olaniyi, H. B.; Olowole, A. F.

    2002-07-01

    Energy dispersive X-ray fluorescence technique was employed to determine the concentrations of elements in aerosol samples collected in the working environment of a secondary lead smelting company in Nigeria. Sampling was done using Whatman-41 cellulose filters mounted in Negretti air samplers at 10 locations within the factory. The concentrations of eight elements (K, Ca, Ti, Mn, Fe, Cu, Zn and Pb) were determined. The TSP values ranged from 70 to 7963 μg/m 3 and the concentration of Pb was found to be between 2.98 and 538.47 μg/m 3. The high Pb concentration is a danger signal to the health of the factory workers.

  10. A preliminary evaluation of stream sediment sampling for the detection of cobalt mineralization in the Bou Azzer District, Morocco

    USGS Publications Warehouse

    Foose, M.P.

    1983-01-01

    Analyses of 28 stream sediment samples collected in the Bou Azzer district, Morocco, show that this sampling technique may be useful in locating the cobalt arsenide mineralization that exists in this area. The absence of exceptionally high values of cobalt and arsenic, the nearly lognormal distribution of cobalt values, and the lack of correlation between the highest values of cobalt and arsenic were unanticipated results that do not support the use of this sampling technique. However, highest values of several metals, including cobalt, were associated with an identified area of cobalt mineralization, and high cobalt was present near a second area in which cobalt mineralization is suspected. Although probably mostly reflecting the geochemistry of unexposed ultramafic rocks, the association of these metals with mineralization shows that this type of sampling can independently locate areas of known or potential cobalt mineralization.

  11. Technical note: A device for obtaining time-integrated samples of ruminal fluid

    USGS Publications Warehouse

    Corley, R. N.; Murphy, M.R.; Lucena, J.; Panno, S.V.

    1999-01-01

    A device was adapted to allow for time-integrated sampling of fluid from the rumen via a cannula. The sampler consisted of a cup-shaped ceramic filter positioned in the ventral rumen of a cannulated cow and attached to a tube through which fluid entering the filter was removed continuously using a peristaltic pump. Rate of ruminal fluid removal using the device was monitored over two 36-h periods (at 6-h intervals) and was not affected (P > .05) by time, indicating that the system was not susceptible to clogging during this period. Two cows having ad libitum access to a totally mixed ration were used in a split-block design to evaluate the utility of the system for obtaining time-integrated samples of ruminal fluid. Ruminal fluid VFA concentration and pattern in samples collected in two replicated 8-h periods by the time-integrated sampler (at 1-h intervals) were compared with composite samples collected using a conventional suction-strainer device (at 30-min intervals). Each 8-h collection period started 2 h before or 6 h after feeding. Results indicated that total VFA concentration was not affected (P > .05) by the sampling method. Volatile fatty acid patterns were likewise unaffected (P > .05) except that acetate was 2.5% higher (P < .05) in samples collected 2 h before feeding and valerate was 5% higher (P < .05) in samples collected 6 h after feeding by the suction-strainer device. Although significant, these differences were not considered physiologically important. We concluded that use of the ceramic filter improved the sampling of ruminal fluid by simplifying the technique and allowing time-integrated samples to be obtained.

  12. Isotope analysis of crystalline impact melt rocks from Apollo 16 stations 11 and 13, North Ray Crater

    NASA Technical Reports Server (NTRS)

    Reimold, W. U.; Nyquist, L. E.; Bansal, B. M.; Shih, C.-Y.; Weismann, H.; Wooden, J. L.; Mackinnon, I. D. R.

    1985-01-01

    The North Ray Crater Target Rock Consortium was formed to study a large number of rake samples collected at Apollo 16 stations 11 and 13 with comparative chemical, mineralogical, and chronological techniques in order to provide a larger data base for the discussion of lunar highland evolution in the vicinity of the Apollo 16 landing region. The present investigation is concerned with Rb-Sr and Sm-Nd isotopic analyses of a number of whole-rock samples of feldspathic microporhyritic (FM) impact melt, a sample type especially abundant among the North Ray crater (station 11) sample collection. Aspects of sample mineralogy and analytical procedures are discussed, taking into account FM impact melt rocks 6715 and 63538, intergranular impact melt rock 67775, subophitic impact melt rock 67747, subophitic impact melt rock 67559, and studies based on the utilization of electron microscopy and mass spectroscopy.

  13. USE OF NATURAL WATERS AS U. S. GEOLOGICAL SURVEY REFERENCE SAMPLES.

    USGS Publications Warehouse

    Janzer, Victor J.

    1985-01-01

    The U. S. Geological Survey conducts research and collects hydrologic data relating to the Nation's water resources. Seven types of natural matrix reference water samples are prepared for use in the Survey's quality assurance program. These include samples containing major constituents, trace metals, nutrients, herbicides, insecticides, trace metals in a water and suspended-sediment mixture, and precipitation (snowmelt). To prepare these reference samples, natural water is collected in plastic drums and the sediment is allowed to settle. The water is then filtered, selected constituents are added, and if necessary the water is acidified and sterilized by ultraviolet irradiation before bottling in plastic or glass. These reference samples are distributed twice yearly to more than 100 laboratories for chemical analysis. The most probable values for each constituent are determined by evaluating the data submitted by the laboratories using statistical techniques recommended by ASTM.

  14. Evaluation of a standardized micro-vacuum sampling method for collection of surface dust.

    PubMed

    Ashley, Kevin; Applegate, Gregory T; Wise, Tamara J; Fernback, Joseph E; Goldcamp, Michael J

    2007-03-01

    A standardized procedure for collecting dust samples from surfaces using a micro-vacuum sampling technique was evaluated. Experiments were carried out to investigate the collection efficiency of the vacuum sampling method described in ASTM Standard D7144, "Standard Practice for Collection of Surface Dust by Micro-Vacuum Sampling for Subsequent Metals Determination." Weighed masses ( approximately 5, approximately 10 and approximately 25 mg) of three NIST Standard Reference Materials (SRMs) were spiked onto surfaces of various substrates. The SRMs used were: (1) Powdered Lead-Based Paint; (2) Urban Particulate Matter; and (3) Trace Elements in Indoor Dust. Twelve different substrate materials were chosen to be representative of surfaces commonly encountered in occupational and/or indoor settings: (1) wood, (2) tile, (3) linoleum, (4) vinyl, (5) industrial carpet, (6) plush carpet, (7,8) concrete block (painted and unpainted), (9) car seat material, (10) denim, (11) steel, and (12) glass. Samples of SRMs originally spiked onto these surfaces were collected using the standardized micro-vacuum sampling procedure. Gravimetric analysis of material collected within preweighed Accucapinserts (housed within the samplers) was used to measure SRM recoveries. Recoveries ranged from 21.6% (+/- 10.4%, 95% confidence limit [CL]) for SRM 1579 from industrial carpet to 59.2% (+/- 11.0%, 95% CL) for SRM 1579 from glass. For most SRM/substrate combinations, recoveries ranged from approximately 25% to approximately 50%; variabilities differed appreciably. In general, SRM recoveries were higher from smooth and hard surfaces and lower from rough and porous surfaces. Material captured within collection nozzles attached to the sampler inlets was also weighed. A significant fraction of SRM originally spiked onto substrate surfaces was captured within collection nozzles. Percentages of SRMs captured within collection nozzles ranged from approximately 13% (+/- 4 - +/- 5%, 95% CLs) for SRMs 1579 and 2583 from industrial carpet to approximately 45% (+/- 7 - +/- 26%, 95% CLs) for SRM 1648 from glass, tile and steel. For some substrates, loose material from the substrate itself (i.e., substrate particles and fibers) was sometimes collected along with the SRM, both within Accucaps as well as collection nozzles. Co-collection of substrate material can bias results and contribute to sampling variability. The results of this work have provided performance data on the standardized micro-vacuum sampling procedure.

  15. A Technique for Airborne Aerobiological Sampling

    ERIC Educational Resources Information Center

    Mill, R. A.; And Others

    1972-01-01

    Report of a study of airborne micro-organisms collected over the Oklahoma City Metropolitan area and immediate environments, to investigate the possibility that a cloud of such organisms might account for the prevalence of some respiratory diseases in and around urban areas. (LK)

  16. USE OF EXHALED BREATH CONDENSATE IN A HUMAN EXPOSURE STUDY

    EPA Science Inventory

    Exhaled breath condensate (EBC) is a noninvasive, repeatable collection technique to sample biomarkers of lung inflammation, oxidative stress, and environmental exposure. It is unclear whether EBC is an effective tool in human environmental exposure studies with multi-day samplin...

  17. Usage Analysis of Web 2.0 and Library 2.0 Tools by Librarians in Kwara State Academic Libraries

    ERIC Educational Resources Information Center

    Tella, Adeyinka; Soluoku, Taofeeqat

    2016-01-01

    This study analysed the usage of Web 2.0 and Library 2.0 tools by librarians in Kwara State academic libraries. A sample of 40 librarians was surveyed through total enumeration sampling technique from four different tertiary education institutions libraries in Kwara State, Nigeria. Questionnaire was used for the collection of data. The collected…

  18. Development of microsatellite markers and a restriction endonuclease digest assay for non-invasive sampling of endangered white-rumped, slender-billed and red-headed vultues

    Treesearch

    Y.A. Kapetanakos; I.J. Lovette; T.E. Katzner

    2014-01-01

    Southeast Asian vultures have been greatly reduced in range and population numbers, but it is challenging to use traditional tagging and monitoring techniques to track changes in their populations. Genotypes derived from non-invasively collected feather samples provide an alternative and effective means to 'capture' individual vultures for mark-recapture...

  19. Mechanical Abrasion as a Low Cost Technique for Contamination-Free Sample Acquisition from a Category IVA Clean Platform

    NASA Technical Reports Server (NTRS)

    Dolgin, B.; Yarbrough, C.; Carson, J.; Troy, R.

    2000-01-01

    The proposed Mars Sample Transfer Chain Architecture provides Planetary Protection Officers with clean samples that are required for the eventual release from confinement of the returned Martian samples. At the same time, absolute cleanliness and sterility requirement is not placed of any part of the Lander (including the deep drill), Mars Assent Vehicle (MAV), any part of the Orbiting Sample container (OS), Rover mobility platform, any part of the Minicorer, Robotic arm (including instrument sensors), and most of the caching equipment on the Rover. The removal of the strict requirements in excess of the Category IVa cleanliness (Pathfinder clean) is expected to lead to significant cost savings. The proposed architecture assumes that crosscontamination renders all surfaces in the vicinity of the rover(s) and the lander(s) contaminated. Thus, no accessible surface of Martian rocks and soil is Earth contamination free. As a result of the latter, only subsurface samples (either rock or soil) can be and will be collected for eventual return to Earth. Uncontaminated samples can be collected from a Category IVa clean platform. Both subsurface soil and rock samples can be maintained clean if they are collected by devices that are self-contained and clean and sterile inside only. The top layer of the sample is removed in a manner that does not contaminate the collection tools. Biobarrier (e.g., aluminum foil) covering the moving parts of these devices may be used as the only self removing bio-blanket that is required. The samples never leave the collection tools. The lids are placed on these tools inside the collection device. These single use tools with the lid and the sample inside are brought to Earth in the OS. The lids have to be designed impenetrable to the Earth organisms. The latter is a well established art.

  20. Mechanisms of sampling interstitial fluid from skin using a microneedle patch.

    PubMed

    Samant, Pradnya P; Prausnitz, Mark R

    2018-05-01

    Although interstitial fluid (ISF) contains biomarkers of physiological significance and medical interest, sampling of ISF for clinical applications has made limited impact due to a lack of simple, clinically useful techniques that collect more than nanoliter volumes of ISF. This study describes experimental and theoretical analysis of ISF transport from skin using microneedle (MN) patches and demonstrates collection of >1 µL of ISF within 20 min in pig cadaver skin and living human subjects using an optimized system. MN patches containing arrays of submillimeter solid, porous, or hollow needles were used to penetrate superficial skin layers and access ISF through micropores (µpores) formed upon insertion. Experimental studies in pig skin found that ISF collection depended on transport mechanism according to the rank order diffusion < capillary action < osmosis < pressure-driven convection, under the conditions studied. These findings were in agreement with independent theoretical modeling that considered transport within skin, across the interface between skin and µpores, and within µpores to the skin surface. This analysis indicated that the rate-limiting step for ISF sampling is transport through the dermis. Based on these studies and other considerations like safety and convenience for future clinical use, we designed an MN patch prototype to sample ISF using suction as the driving force. Using this approach, we collected ISF from human volunteers and identified the presence of biomarkers in the collected ISF. In this way, sampling ISF from skin using an MN patch could enable collection of ISF for use in research and medicine.

  1. Tests on the centrifugal flotation technique and its use in estimating the prevalence of Toxocara in soil samples from urban and suburban areas of Malaysia.

    PubMed

    Loh, A G; Israf, D A

    1998-03-01

    The influence of soil texture (silt, sand and laterite) and flotation solutions (saturated NaCl, sucrose, NaNO3, and ZnSO4) upon the recovery of Toxocara ova from seeded soil samples with the centrifugal flotation technique was investigated. Soil samples of different texture were artificially seeded with Toxocara spp. ova and subjected to a centrifugal flotation technique which used various flotation solutions. The results showed significant (P < 0.001) interactions between the soil types and the flotation solutions. The highest percentage of ova recovery was obtained with silty soil (34.9-100.8%) with saturated NaCl as the flotation solution (45.3-100.8%). A combination of washing of soil samples with 0.1% Tween 80, and flotation using saturated NaCl and a 30 min coverslip recovery period was used to study the prevalence of contamination of soil samples. Forty-six soil samples were collected from up to 24 public parks/playgrounds in urban areas of Petaling Jaya and suburban areas of Serdang. The prevalence of Toxocara species in the urban and suburban areas was 54.5% and 45.8% respectively.

  2. Reducing sampling error in faecal egg counts from black rhinoceros (Diceros bicornis).

    PubMed

    Stringer, Andrew P; Smith, Diane; Kerley, Graham I H; Linklater, Wayne L

    2014-04-01

    Faecal egg counts (FECs) are commonly used for the non-invasive assessment of parasite load within hosts. Sources of error, however, have been identified in laboratory techniques and sample storage. Here we focus on sampling error. We test whether a delay in sample collection can affect FECs, and estimate the number of samples needed to reliably assess mean parasite abundance within a host population. Two commonly found parasite eggs in black rhinoceros (Diceros bicornis) dung, strongyle-type nematodes and Anoplocephala gigantea, were used. We find that collection of dung from the centre of faecal boluses up to six hours after defecation does not affect FECs. More than nine samples were needed to greatly improve confidence intervals of the estimated mean parasite abundance within a host population. These results should improve the cost-effectiveness and efficiency of sampling regimes, and support the usefulness of FECs when used for the non-invasive assessment of parasite abundance in black rhinoceros populations.

  3. A Data-Centric Strategy for Modern Biobanking.

    PubMed

    Quinlan, Philip R; Gardner, Stephen; Groves, Martin; Emes, Richard; Garibaldi, Jonathan

    2015-01-01

    Biobanking has been in existence for many decades and over that time has developed significantly. Biobanking originated from a need to collect, store and make available biological samples for a range of research purposes. It has changed as the understanding of biological processes has increased and new sample handling techniques have been developed to ensure samples were fit-for-purpose.As a result of these developments, modern biobanking is now facing two substantial new challenges. Firstly, new research methods such as next generation sequencing can generate datasets that are at an infinitely greater scale and resolution than previous methods. Secondly, as the understanding of diseases increases researchers require a far richer data set about the donors from which the sample originate.To retain a sample-centric strategy in a research environment that is increasingly dictated by data will place a biobank at a significant disadvantage and even result in the samples collected going unused. As a result biobanking is required to change strategic focus from a sample dominated perspective to a data-centric strategy.

  4. Hemolymph amino acid analysis of individual Drosophila larvae.

    PubMed

    Piyankarage, Sujeewa C; Augustin, Hrvoje; Grosjean, Yael; Featherstone, David E; Shippy, Scott A

    2008-02-15

    One of the most widely used transgenic animal models in biology is Drosophila melanogaster, the fruit fly. Chemical information from this exceedingly small organism is usually accomplished by studying populations to attain sample volumes suitable for standard analysis methods. This paper describes a direct sampling technique capable of obtaining 50-300 nL of hemolymph from individual Drosophila larvae. Hemolymph sampling performed under mineral oil and in air at 30 s intervals up to 120 s after piercing larvae revealed that the effect of evaporation on amino acid concentrations is insignificant when the sample was collected within 60 s. Qualitative and quantitative amino acid analyses of obtained hemolymph were carried out in two optimized buffer conditions by capillary electrophoresis with laser-induced fluorescence detection after derivatizing with fluorescamine. Thirteen amino acids were identified from individual hemolymph samples of both wild-type (WT) control and the genderblind (gb) mutant larvae. The levels of glutamine, glutamate, and taurine in the gb hemolymph were significantly lower at 35%, 38%, and 57% of WT levels, respectively. The developed technique that samples only the hemolymph fluid is efficient and enables accurate organism-level chemical information while minimizing errors associated with possible sample contaminations, estimations, and effects of evaporation compared to the traditional hemolymph-sampling techniques.

  5. Promotional methods used by representatives of drug companies: A prospective survey in general practice

    PubMed Central

    Schramm, Jesper; Andersen, Morten; Vach, Kirstin; Kragstrup, Jakob; Peter Kampmann, Jens; Søndergaard, Jens

    2007-01-01

    Objective To examine the extent and composition of pharmaceutical industry representatives’ marketing techniques with a particular focus on drug sampling in relation to drug age. Design A group of 47 GPs prospectively collected data on drug promotional activities during a six-month period, and a sub-sample of 10 GPs furthermore recorded the representatives’ marketing techniques in detail. Setting Primary healthcare. Subjects General practitioners in the County of Funen, Denmark. Main outcome measures. Promotional visits and corresponding marketing techniques. Results The 47 GPs recorded 1050 visits corresponding to a median of 19 (range 3 to 63) per GP in the six months. The majority of drugs promoted (52%) were marketed more than five years ago. There was a statistically significant decline in the proportion of visits where drug samples were offered with drug age, but the decline was small OR 0.97 (95% CI 0.95;0.98) per year. Leaflets (68%), suggestions on how to improve therapy for a specific patient registered with the practice (53%), drug samples (48%), and gifts (36%) were the most frequently used marketing techniques. Conclusion Drug-industry representatives use a variety of promotional methods. The tendency to hand out drug samples was statistically significantly associated with drug age, but the decline was small. PMID:17497486

  6. Sexing adult black-legged kittiwakes by DNA, behavior, and morphology

    USGS Publications Warehouse

    Jodice, P.G.R.; Lanctot, Richard B.; Gill, V.A.; Roby, D.D.; Hatch, Shyla A.

    2000-01-01

    We sexed adult Black-legged Kittiwakes (Rissa tridactyla) using DNA-based genetic techniques, behavior and morphology and compared results from these techniques. Genetic and morphology data were collected on 605 breeding kittiwakes and sex-specific behaviors were recorded for a sub-sample of 285 of these individuals. We compared sex classification based on both genetic and behavioral techniques for this sub-sample to assess the accuracy of the genetic technique. DNA-based techniques correctly sexed 97.2% and sex-specific behaviors, 96.5% of this sub-sample. We used the corrected genetic classifications from this sub-sample and the genetic classifications for the remaining birds, under the assumption they were correct, to develop predictive morphometric discriminant function models for all 605 birds. These models accurately predicted the sex of 73-96% of individuals examined, depending on the sample of birds used and the characters included. The most accurate single measurement for determining sex was length of head plus bill, which correctly classified 88% of individuals tested. When both members of a pair were measured, classification levels improved and approached the accuracy of both behavioral observations and genetic analyses. Morphometric techniques were only slightly less accurate than genetic techniques but were easier to implement in the field and less costly. Behavioral observations, while highly accurate, required that birds be easily observable during the breeding season and that birds be identifiable. As such, sex-specific behaviors may best be applied as a confirmation of sex for previously marked birds. All three techniques thus have the potential to be highly accurate, and the selection of one or more will depend on the circumstances of any particular field study.

  7. Digital Holographic Microscopy, a Method for Detection of Microorganisms in Plume Samples from Enceladus and Other Icy Worlds

    PubMed Central

    Bedrossian, Manuel; Lindensmith, Chris

    2017-01-01

    Abstract Detection of extant microbial life on Earth and elsewhere in the Solar System requires the ability to identify and enumerate micrometer-scale, essentially featureless cells. On Earth, bacteria are usually enumerated by culture plating or epifluorescence microscopy. Culture plates require long incubation times and can only count culturable strains, and epifluorescence microscopy requires extensive staining and concentration of the sample and instrumentation that is not readily miniaturized for space. Digital holographic microscopy (DHM) represents an alternative technique with no moving parts and higher throughput than traditional microscopy, making it potentially useful in space for detection of extant microorganisms provided that sufficient numbers of cells can be collected. Because sample collection is expected to be the limiting factor for space missions, especially to outer planets, it is important to quantify the limits of detection of any proposed technique for extant life detection. Here we use both laboratory and field samples to measure the limits of detection of an off-axis digital holographic microscope (DHM). A statistical model is used to estimate any instrument's probability of detection at various bacterial concentrations based on the optical performance characteristics of the instrument, as well as estimate the confidence interval of detection. This statistical model agrees well with the limit of detection of 103 cells/mL that was found experimentally with laboratory samples. In environmental samples, active cells were immediately evident at concentrations of 104 cells/mL. Published estimates of cell densities for Enceladus plumes yield up to 104 cells/mL, which are well within the off-axis DHM's limits of detection to confidence intervals greater than or equal to 95%, assuming sufficient sample volumes can be collected. The quantitative phase imaging provided by DHM allowed minerals to be distinguished from cells. Off-axis DHM's ability for rapid low-level bacterial detection and counting shows its viability as a technique for detection of extant microbial life provided that the cells can be captured intact and delivered to the sample chamber in a sufficient volume of liquid for imaging. Key Words: In situ life detection—Extant microorganisms—Holographic microscopy—Ocean Worlds—Enceladus—Imaging. Astrobiology 17, 913–925. PMID:28708412

  8. [Investigation of the presence of Cryptosporidium spp. in different water sources in Mersin province, Turkey].

    PubMed

    Aslan, Gönül; Bayram, Gül; Otağ, Feza; Direkel, Sahin; Taylan Özkan, Ayşegül; Ceber, Kemal; Emekdaş, Gürol

    2012-01-01

    Cryptosporidium is an intracellular protozoon that causes enteritis in human and animals. Contaminated water and food are the major sources for the transmission of oocysts via oral-fecal route. It is reported that the prevalence of cryptosporidiosis is higher in developing countries than developed countries because of inefficient sanitation and disinfection facilities for drinking water. The most frequently detected species is Cryptosporidium parvum leading to high morbidity in healthy subjects and also fatal infections in immunocompromised patients. The acid-fast staining method is widely used in the diagnosis of cryptosporidiosis. Nowadays, Cryptosporidium could easily be detected in water supplies and asymptomatic carriers by molecular techniques to obtain epidemiological data. In this study it was aimed to detect and identify Cryptosporidium oocysts in different water sources in Mersin province, Turkey. A total of 135 water samples (70 taps, 50 wells and 15 sewage) collected from city center (n= 25) and from Tarsus (n= 32), Mezitli (n= 33) and Karaduvar (n= 45) counties between March 2007 and May 2009 were included in the study. Water samples in 10 liter volumes, were filtered by 0.45 µm pore-sized membrane filter vacuum/ pressure pumping technique. Cryptosporidium oocysts in filtrates were detected by modified cold Kinyoun acid-fast stain (MCK) technique and also identified and typed by polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) method. MCK yielded three and PCR yielded seven positive results. All the strains were identified as C.parvum by PCR-RFLP method. All of the three MCK-positive samples were also found positive with PCR, however four PCR positive samples were MCK-negative. Thus, the prevalence of C.parvum was estimated as 5.2% (7/135) in our region. Of seven positive samples, one was a sewage water sample collected from the city center, while the remaining (two tap water, two well water and two sewage water samples) belonged to the samples collected from Karaduvar county, interestingly. It was thought that deficient infrastructure and use of well water as drinking water supply in Karaduvar region might be the cause of high rate of Cryptosporidium (6/45; 13.3%). Further studies which will determine the genotypes and investigate the phylogenetic relationship between these Cryptosporidium spp., might aid to the epidemiology of cryptosporidiosis in our region.

  9. Phylogenetic analysis of bacterial isolates from man-made high-pH, high-salt environments and identification of gene-cassette-associated open reading frames.

    PubMed

    Ghauri, Muhammad A; Khalid, Ahmad M; Grant, Susan; Grant, William D; Heaphy, Shaun

    2006-06-01

    Environmental samples were collected from high-pH sites in Pakistan, including a uranium heap set up for carbonate leaching, the lime unit of a tannery, and the Khewra salt mine. Another sample was collected from a hot spring on the shore of the soda lake, Magadi, in Kenya. Microbial cultures were enriched from Pakistani samples. Phylogenetic analysis of isolates was carried out by sequencing 16S rRNA genes. Genomic DNA was amplified by polymerase chain reaction using integron gene-cassette-specific primers. Different gene-cassette-linked genes were recovered from the cultured strains related to Halomonas magadiensis, Virgibacillus halodenitrificans, and Yania flava and from the uncultured environmental DNA sample. The usefulness of this technique as a tool for gene mining is indicated.

  10. Spectral fingerprinting of polycyclic aromatic hydrocarbons in high-volume ambient air samples by constant energy synchronous luminescence spectroscopy

    USGS Publications Warehouse

    Kerkhoff, M.J.; Lee, T.M.; Allen, E.R.; Lundgren, D.A.; Winefordner, J.D.

    1985-01-01

    A high-volume sampler fitted with a glass-fiber filter and backed by polyurethane foam (PUF) was employed to collect airborne particulate and gas-phase polycylic aromatic hydrocarbons (PAHs) in ambient air. Samples were collected from four sources representing a range of environmental conditions: gasoline engine exhaust, diesel engine exhaust, air near a heavily traveled interstate site, and air from a moderately polluted urban site. Spectral fingerprints of the unseparated particulate and gas-phase samples were obtained by constant energy synchronous luminescence spectroscopy (CESLS). Five major PAHs in the gas-phase extracts were characterized and estimated. The compatibility of a high-volume sampling method using polyurethane foam coupled with CESLS detection is explored for use as a screening technique for PAHs in ambient air. ?? 1985 American Chemical Society.

  11. The application of welat latino for creating paes in solo wedding bride

    NASA Astrophysics Data System (ADS)

    Ihsani, Ade Novi Nurul; Krisnawati, Maria; Prasetyaningtyas, Wulansari; Anggraeni, Puput; Bela, Herlina Tria; Zunaedah, Putri Wahyu

    2018-03-01

    The purposes of this research were: 1) to find out the process of creating innovative welat, 2) to find out how to use innovative welat for Solo wedding bride paes creation. The method used in the research was research and development (R & D). Sampling technique in this research was purposive sampling by using 13 people as models. The data collection technique used observation and documentation. Data analysis technique used descriptive technique. The results of the study showed that 1) there were two times design change of the validity of welat creation, each product passed through several stages of designing, forming, determining the material and printing, 3) the first way of using the welat determined the distance dot between the cengkorongan of both forms by using welat according to the existed mold. In conclusion, Innovative welat can produce paes in accordance with the standard and shorten the process.

  12. Explosive detection technology

    NASA Astrophysics Data System (ADS)

    Doremus, Steven; Crownover, Robin

    2017-05-01

    The continuing proliferation of improvised explosive devices is an omnipresent threat to civilians and members of military and law enforcement around the world. The ability to accurately and quickly detect explosive materials from a distance would be an extremely valuable tool for mitigating the risk posed by these devices. A variety of techniques exist that are capable of accurately identifying explosive compounds, but an effective standoff technique is still yet to be realized. Most of the methods being investigated to fill this gap in capabilities are laser based. Raman spectroscopy is one such technique that has been demonstrated to be effective at a distance. Spatially Offset Raman Spectroscopy (SORS) is a technique capable of identifying chemical compounds inside of containers, which could be used to detect hidden explosive devices. Coherent Anti-Stokes Raman Spectroscopy (CARS) utilized a coherent pair of lasers to excite a sample, greatly increasing the response of sample while decreasing the strength of the lasers being used, which significantly improves the eye safety issue that typically hinders laser-based detection methods. Time-gating techniques are also being developed to improve the data collection from Raman techniques, which are often hindered fluorescence of the test sample in addition to atmospheric, substrate, and contaminant responses. Ultraviolet based techniques have also shown significant promise by greatly improved signal strength from excitation of resonance in many explosive compounds. Raman spectroscopy, which identifies compounds based on their molecular response, can be coupled with Laser Induced Breakdown Spectroscopy (LIBS) capable of characterizing the sample's atomic composition using a single laser.

  13. Techniques for evaluating digestibility of energy, amino acids, phosphorus, and calcium in feed ingredients for pigs.

    PubMed

    Zhang, Fengrui; Adeola, Olayiwola

    2017-12-01

    Sound feed formulation is dependent upon precise evaluation of energy and nutrients values in feed ingredients. Hence the methodology to determine the digestibility of energy and nutrients in feedstuffs should be chosen carefully before conducting experiments. The direct and difference procedures are widely used to determine the digestibility of energy and nutrients in feedstuffs. The direct procedure is normally considered when the test feedstuff can be formulated as the sole source of the component of interest in the test diet. However, in some cases where test ingredients can only be formulated to replace a portion of the basal diet to provide the component of interest, the difference procedure can be applied to get equally robust values. Based on components of interest, ileal digesta or feces can be collected, and different sample collection processes can be used. For example, for amino acids (AA), to avoid the interference of fermentation in the hind gut, ileal digesta samples are collected to determine the ileal digestibility and simple T-cannula and index method are commonly used techniques for AA digestibility analysis. For energy, phosphorus, and calcium, normally fecal samples will be collected to determine the total tract digestibility, and therefore the total collection method is recommended to obtain more accurate estimates. Concerns with the use of apparent digestibility values include different estimated values from different inclusion level and non-additivity in mixtures of feed ingredients. These concerns can be overcome by using standardized digestibility, or true digestibility, by correcting endogenous losses of components from apparent digestibility values. In this review, methodologies used to determine energy and nutrients digestibility in pigs are discussed. It is suggested that the methodology should be carefully selected based on the component of interest, feed ingredients, and available experimental facilities.

  14. Evidence for false-positive results for boldenone testing of veal urine due to faecal cross-contamination during sampling.

    PubMed

    Sgoifo Rossi, C A; Arioli, F; Bassini, A; Chiesa, L M; Dell'Orto, V; Montana, M; Pompa, G

    2004-08-01

    European Directive 96/22/EC, which controls veterinary residues in animals, does not permit the presence of synthetic growth promoters in products of animal origin or in livestock. Boldenone is categorized in class A3 (growth promoters -- steroids) and is thus a banned substance. Testing of veal urine for banned substances is part of the European Union statutory programme for animals going into the food chain. In relation to this monitoring, three studies were conducted to investigate the apparent presence of the banned growth promoter boldenone in veal urine, which was suspected as being caused by interference from faecal contamination of the sample. In the first study, urine samples were collected at different times (time 0 and after 30 min) using (1) a conventional zoonotechnical apron and (2) a technique designed specifically to avoid faecal contamination ('kettle'). This resulted in samples that were, respectively, positive and negative for the presence of alpha-boldenone (alpha-BOL). In a second study, urine samples negative to alpha-BOL were collected from eight veal calves, but became positive after deliberate faecal contamination. In a third study, data obtained from the Italian RNP (Residual National Program) indicated that 18.1% of 3295 urine samples collected using the zootechnical apron were positive for alpha-BOL and 2.1% for beta-boldenone (beta-BOL), whilst of 902 samples collected using the kettle, beta-BOL was not detected in any samples and only 0.2% were positive to alpha-BOL, in concentrations lower than 2 ng ml(-1). These results further support the supposition that faecal contamination of the urine during sample collection can lead to false-positive results during boldenone analysis.

  15. Assessment of Blood Collection from the Lateral Saphenous Vein for Microfilaria Counts in Mongolian Gerbils (Meriones unguiculatus) Infected with Brugia pahangi

    PubMed Central

    Alworth, Leanne C; Berghaus, Roy D; Kelly, Lisa M; Supakorndej, Prasit; Burkman, Erica J; Savadelis, Molly D; Cooper, Tanya L; Salyards, Gregory W; Harvey, Stephen B; Moorhead, Andrew R

    2015-01-01

    The NIH guidelines for survival bleeding of mice and rats note that using the retroorbital plexus has a greater potential for complications than do other methods of blood collection and that this procedure should be performed on anesthetized animals. Lateral saphenous vein puncture has a low potential for complications and can be performed without anesthesia. Mongolian gerbils (Meriones unguiculatus) are the preferred rodent model for filarial parasite research. To monitor microfilaria counts in the blood, blood sampling from the orbital plexus has been the standard. Our goal was to refine the blood collection technique. To determine whether blood collection from the lateral saphenous vein was a feasible alternative to retroorbital sampling, we compared microfilaria counts in blood samples collected by both methods from 21 gerbils infected with the filarial parasitic worm Brugia pahangi. Lateral saphenous vein counts were equivalent to retroorbital counts at relatively high counts (greater than 50 microfilariae per 20 µL) but were significantly lower than retroorbital counts when microfilarial concentrations were lower. Our results indicate that although retroorbital collection may be preferable when low concentrations of microfilariae need to be enumerated, the lateral saphenous vein is a suitable alternative site for blood sampling to determine microfilaremia and is a feasible refinement that can benefit the wellbeing of gerbils. PMID:26678366

  16. Ethanol and sodium acetate as a preservation method to delay degradation of environmental DNA

    USGS Publications Warehouse

    Ladell, Bridget A.; Walleser, Liza R.; McCalla, S. Grace; Erickson, Richard A.; Amberg, Jon J.

    2018-01-01

    Environmental DNA (eDNA) samples that are collected from remote locations depend on rapid stabilization of the DNA. The degradation of eDNA in water samples is minimized when samples are stored at ≤ 4 °C. Developing a preservation technique to maintain eDNA integrity at room temperature would allow a wider range of locations to be sampled. We evaluated an ethanol and sodium acetate solution to maintain the integrity of the DNA samples for the time between collection and lab testing. For this evaluation, replicate water samples taken from a tank housing Asian carp were placed on ice or held at room temperature. At both temperatures, water samples were left untreated or were preserved with an ethanol and sodium acetate solution (EtOH–NaAc). Every day for 6 days following collection, a subset of the samples was removed from each preservation method and DNA was extracted and nuclear and mitochondrial markers were assayed with qPCR. Results showed comparable persistence of DNA between iced samples without the EtOH–NaAc treatment and samples that received EtOH–NaAc treatment that were kept at room temperature. We found that DNA can be amplified from preserved samples using an EtOH–NaAc solution after up to 7 days at room temperature.

  17. Method for concentration and separation of biological organisms by ultrafiltration and dielectrophoresis

    DOEpatents

    Simmons, Blake A.; Hill, Vincent R.; Fintschenko, Yolanda; Cummings, Eric B.

    2012-09-04

    Disclosed is a method for monitoring sources of public water supply for a variety of pathogens by using a combination of ultrafiltration techniques together dielectrophoretic separation techniques. Because water-borne pathogens, whether present due to "natural" contamination or intentional introduction, would likely be present in drinking water at low concentrations when samples are collected for monitoring or outbreak investigations, an approach is needed to quickly and efficiently concentrate and separate particles such as viruses, bacteria, and parasites in large volumes of water (e.g., 100 L or more) while simultaneously reducing the sample volume to levels sufficient for detecting low concentrations of microbes (e.g., <10 mL). The technique is also designed to screen the separated microbes based on specific conductivity and size.

  18. Optimising the collection of female genital tract fluid for cytokine analysis in pregnant women.

    PubMed

    Short, C S; Quinlan, R; Bennett, P; Shattock, R J; Taylor, G P

    2018-07-01

    To better understand the immunology of pregnancy, study of female genital tract fluid (FGF) is desirable. However the optimum method of collection of FGF in pregnant women for immunological methods, specifically cytokine measurement, is unknown. A prospective study of HIV-uninfected pregnant women comparing two methods of FGF collection: polyvinyl acetal sponge collection of cervical fluid (CF) and menstrual cup collection of cervicovaginal fluid (CVF). Samples were collected at 3 time points across the second and third trimesters: 14-21, 22-25 and 26-31 weeks. Multiplex chemi-luminescent assays were used to measure: IFN-γ, IL-1β, IL-2, IL-4, IL-6, IL-8, IL-10, IL-12, IL-13 and TNF-α. Optimal methodology for cytokine normalisation (sample weight, volume and total protein) was explored. All cytokines were measurable in both fluid types. IL-1β, IL-8 and IL-6 were detected at the highest concentrations (ranking order CF > CVF > plasma). CVF collection was simpler, provided the largest volume of sample (median 0.5 g) with the potential for undiluted usage, and allowed for self-insertion. CF cytokine concentrations were intrinsically associated with sample weight and protein concentration however CVF cytokines were independent of these. Both methods of collection are robust for measurement of FGF cytokines during pregnancy. We recommend CVF collection using a menstrual cup as a viable option in pregnant women for high dimensional biological techniques. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Aerosol Sampling Experiment on the International Space Station

    NASA Technical Reports Server (NTRS)

    Meyer, Marit E.

    2017-01-01

    The International Space Station (ISS) is a unique indoor environment which serves as both home and workplace to the astronaut crew. There is currently no particulate monitoring, although particulate matter requirements exist. An experiment to collect particles in the ISS cabin was conducted recently. Two different aerosol samplers were used for redundancy and to collect particles in two size ranges spanning from 10 nm to hundreds of micrometers. The Active Sampler is a battery operated thermophoretic sampler with an internal pump which draws in air and collects particles directly on a transmission electron microscope grid. This commercial-off-the-shelf device was modified for operation in low gravity. The Passive Sampler has five sampling surfaces which were exposed to air for different durations in order to collect at least one sample with an optimal quantity of particles for microscopy. These samples were returned to Earth for analysis with a variety of techniques to obtain long-term average concentrations and identify particle emission sources. Results are compared with the inventory of ISS aerosols which was created based on sparse data and the literature. The goal of the experiment is to obtain data on indoor aerosols on ISS for future particulate monitor design and development.

  20. Self-Collected versus Clinician-Collected Sampling for Chlamydia and Gonorrhea Screening: A Systemic Review and Meta-Analysis

    PubMed Central

    Lunny, Carole; Taylor, Darlene; Hoang, Linda; Wong, Tom; Gilbert, Mark; Lester, Richard; Krajden, Mel; Ogilvie, Gina

    2015-01-01

    Background The increases in STI rates since the late 1990s in Canada have occurred despite widespread primary care and targeted public health programs and in the setting of universal health care. More innovative interventions are required that would eliminate barriers to STI testing such as internet-based or mail-in home and community service testing for patients that are hard to reach, who refuse to go for clinician-based testing, or who decline an examination. Jurisdictions such as New Zealand and some American states currently use self-collected sampling, but without the required evidence to determine whether self-collected specimens are as accurate as clinician-collected specimens in terms of chlamydia and gonorrhea diagnostic accuracy. The objective of the review is to compare self-collected vaginal, urine, pharyngeal and rectal samples to our reference standard - clinician-collected cervical, urethral, pharyngeal and rectal sampling techniques to identify a positive specimen using nucleic acid amplification test assays. Methods The hierarchical summary receiver operating characteristic and the fixed effect models were used to assess the accuracy of comparable specimens that were collected by patients compared to clinicians. Sensitivity and specificity estimates with 95% confidence intervals (CI) were reported as our main outcome measures. Findings We included 21 studies based on over 6100 paired samples. Fourteen included studies examined chlamydia only, 6 compared both gonorrhea and chlamydia separately in the same study, and one examined gonorrhea. The six chlamydia studies comparing self-collection by vaginal swab to a clinician-collected cervical swab had the highest sensitivity (92%, 95% CI 87-95) and specificity (98%, 95% CI 97-99), compared to other specimen-types (urine/urethra or urine/cervix). Six studies compared urine self-samples to urethra clinician-collected samples in males and produced a sensitivity of 88% (95% CI 83-93) and a specificity of 99% (95% CI 0.94-0.99). Taking into account that urine samples may be less sensitive than cervical samples, eight chlamydia studies that compared urine self-collected verses clinician-collected cervical samples had a sensitivity of 87% (95% CI 81-91) and high specificity of 99% (95% CI 0.98-1.00). For gonorrhea testing, self-collected urine samples compared to clinician-collected urethra samples in males produced a sensitivity of 92% (95% CI 83-97) and specificity of 99% (95% CI 0.98-1.00). Conclusion The sensitivity and specificity of vaginal self-collected swabs compared to swabs collected by clinicians supports the use of vaginal swab as the recommended specimen of choice in home-based screening for chlamydia and gonorrhea. Urine samples for gonorrhea collected by men had comparably high sensitivity and specificity, so could be recommended as they can be left at room temperature for several days, allowing for the possibility of mail-in home-based testing. In populations that may not go for testing at all, do not have the option of clinical testing, or who refuse a clinical examination, self-collected screening would be a good alternative. We recommend that guidelines on how to self-collect gonorrhea and chlamydia urine, vaginal, rectal and pharyngeal specimens be published. PMID:26168051

  1. The Colorado/Missouri 1989 cirrus mini IFO

    NASA Technical Reports Server (NTRS)

    Heymsfield, Andrew J.; Hagen, Donald

    1990-01-01

    A series of experiments with aircraft were planned for Nov. and Dec. 1989 to study cirrus ice crystal nucleation mechanisms and to test new aircraft instrumentation. The measurements were conducted using the NCAR Sabreliner and King Air. Sampling was conducted near Boulder, Colorado, in lenticular (mountain wave) clouds, and over Missouri in cirrus generating cells. Field samples of aerosol and ice crystal replicas and melt water from these cirrus clouds were collected and studied. Aircraft instrumentation and sampling techniques are discussed.

  2. Area estimation using multiyear designs and partial crop identification

    NASA Technical Reports Server (NTRS)

    Sielken, R. L., Jr.

    1984-01-01

    Statistical procedures were developed for large area assessments using both satellite and conventional data. Crop acreages, other ground cover indices, and measures of change were the principal characteristics of interest. These characteristics are capable of being estimated from samples collected possibly from several sources at varying times, with different levels of identification. Multiyear analysis techniques were extended to include partially identified samples; the best current year sampling design corresponding to a given sampling history was determined; weights reflecting the precision or confidence in each observation were identified and utilized, and the variation in estimates incorporating partially identified samples were quantified.

  3. Efficiently sampling conformations and pathways using the concurrent adaptive sampling (CAS) algorithm

    NASA Astrophysics Data System (ADS)

    Ahn, Surl-Hee; Grate, Jay W.; Darve, Eric F.

    2017-08-01

    Molecular dynamics simulations are useful in obtaining thermodynamic and kinetic properties of bio-molecules, but they are limited by the time scale barrier. That is, we may not obtain properties' efficiently because we need to run microseconds or longer simulations using femtosecond time steps. To overcome this time scale barrier, we can use the weighted ensemble (WE) method, a powerful enhanced sampling method that efficiently samples thermodynamic and kinetic properties. However, the WE method requires an appropriate partitioning of phase space into discrete macrostates, which can be problematic when we have a high-dimensional collective space or when little is known a priori about the molecular system. Hence, we developed a new WE-based method, called the "Concurrent Adaptive Sampling (CAS) algorithm," to tackle these issues. The CAS algorithm is not constrained to use only one or two collective variables, unlike most reaction coordinate-dependent methods. Instead, it can use a large number of collective variables and adaptive macrostates to enhance the sampling in the high-dimensional space. This is especially useful for systems in which we do not know what the right reaction coordinates are, in which case we can use many collective variables to sample conformations and pathways. In addition, a clustering technique based on the committor function is used to accelerate sampling the slowest process in the molecular system. In this paper, we introduce the new method and show results from two-dimensional models and bio-molecules, specifically penta-alanine and a triazine trimer.

  4. Identifying Careless Responses in Survey Data

    ERIC Educational Resources Information Center

    Meade, Adam W.; Craig, S. Bartholomew

    2012-01-01

    When data are collected via anonymous Internet surveys, particularly under conditions of obligatory participation (such as with student samples), data quality can be a concern. However, little guidance exists in the published literature regarding techniques for detecting careless responses. Previously several potential approaches have been…

  5. Diversity of micro-fungi in an Antarctic dry valley

    NASA Technical Reports Server (NTRS)

    Baublis, J. A.; Wharton, R. A. Jr; Volz, P. A.; Wharton RA, J. r. (Principal Investigator)

    1991-01-01

    The fungal microflora of a dry valley in Southern Victoria Land near McMurdo Sound, Antarctica, was investigated. Samples were collected from introduced objects such as a mummified penguin and spent chewing tobacco in addition to the sparse soil found in rock fissures, isolated moss colonies, shoreline deposit materials, CaCO3 precipitates, and microbial mat debris obtained from the frozen surface of the lake in the basin of Taylor Valley. Using conventional media and techniques, all collection sites yielded populations of yeasts and filamentous fungi. Water samples and live microbial mats from beneath the lake ice yielded species of fungi along with an abundance of bacteria.

  6. The use of mass spectrometry to analyze dried blood spots.

    PubMed

    Wagner, Michel; Tonoli, David; Varesio, Emmanuel; Hopfgartner, Gérard

    2016-01-01

    Dried blood spots (DBS) typically consist in the deposition of small volumes of capillary blood onto dedicated paper cards. Comparatively to whole blood or plasma samples, their benefits rely in the fact that sample collection is easier and that logistic aspects related to sample storage and shipment can be relatively limited, respectively, without the need of a refrigerator or dry ice. Originally, this approach has been developed in the sixties to support the analysis of phenylalanine for the detection of phenylketonuria in newborns using bacterial inhibition test. In the nineties tandem mass spectrometry was established as the detection technique for phenylalanine and tyrosine. DBS became rapidly recognized for their clinical value: they were widely implemented in pediatric settings with mass spectrometric detection, and were closely associated to the debut of newborn screening (NBS) programs, as a part of public health policies. Since then, sample collection on paper cards has been explored with various analytical techniques in other areas more or less successfully regarding large-scale applications. Moreover, in the last 5 years a regain of interest for DBS was observed and originated from the bioanalytical community to support drug development (e.g., PK studies) or therapeutic drug monitoring mainly. Those recent applications were essentially driven by improved sensitivity of triple quadrupole mass spectrometers. This review presents an overall view of all instrumental and methodological developments for DBS analysis with mass spectrometric detection, with and without separation techniques. A general introduction to DBS will describe their advantages and historical aspects of their emergence. A second section will focus on blood collection, with a strong emphasis on specific parameters that can impact quantitative analysis, including chromatographic effects, hematocrit effects, blood effects, and analyte stability. A third part of the review is dedicated to sample preparation and will consider off-line and on-line extractions; in particular, instrumental designs that have been developed so far for DBS extraction will be detailed. Flow injection analysis and applications will be discussed in section IV. The application of surface analysis mass spectrometry (DESI, paper spray, DART, APTDCI, MALDI, LDTD-APCI, and ICP) to DBS is described in section V, while applications based on separation techniques (e.g., liquid or gas chromatography) are presented in section VI. To conclude this review, the current status of DBS analysis is summarized, and future perspectives are provided. © 2014 Wiley Periodicals, Inc.

  7. An evaluation of sources of nitrogen in shallow groundwater using (15)N abundance technique.

    PubMed

    Alva, A K; Dou, H; Paramasivam, S; Wang, F L; Graetz, D A; Sajwan, K S

    2006-01-01

    A (15)N abundance technique was employed to identify the source of NO(3)-N in groundwater under three commercial citrus production sites in central Florida. Water samples were collected from 0 to 300 and 300 to 600 cm depths in the surficial aquifer and analyzed for NO(3)-N and delta N-15 (delta (15)N). Groundwater samples were also collected in a residential area adjacent to one of the citrus groves and analyzed for NO(3)-N and delta (15)N. The delta (15)N values were in the range of (+)1 to (+)10% in both depths underneath the citrus groves. The range of delta (15)N measured in this study represents the range expected for groundwater that was impacted by NO(3)-N originated from mineralization of organic N from the soil as well as from the crop residue. There are occasional high delta (15)N values which are indicative of the effects of NH(3) volatilization losses of applied fertilizer N. The range of delta (15)N values for groundwater samples collected from the residential area adjacent to the citrus groves was very similar to that from the groundwater underneath the citrus groves. Thus, the source of NO(3)-N that impacted the groundwater under the citrus groves also impacted the groundwater in the adjacent residential area.

  8. Locations and descriptions of gravity, box, and push cores collected in San Francisco Bay between January and February, 1990 and 1991

    USGS Publications Warehouse

    Anima, Roberto J.; Clifton, H. Edward; Reiss, Carol; Wong, Florence L.

    2005-01-01

    A project to study San Francisco Bay sediments collected over 300 sediment gravity cores; six push cores, and three box cores in San Francisco Bay during the years 1990-91. The purpose of the sampling effort is to establish a database on the Holocene sediment history of the bay. The samples described and mapped are the first effort to catalog and present the data collected. Thus far the cores have been utilized in various cooperative studies with state colleges and universities, and other USGS divisions. These cores serve as a base for ongoing multidisciplinary studies. The sediment studies project has initiated subsequent coring efforts within the bay using refined coring techniques to attain deeper cores.

  9. Reliability of a new technique for the determination of vitamin B12 absorption in children: single stool sample test--a double isotope technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hjelt, K.

    1986-03-01

    The fractional vitamin B12 absorption (FAB12) was determined in 39 patients with various gastrointestinal diseases by a double-isotope technique, employing a single stool sample test (SSST), as well as a complete stool collection. The age of the patients ranged from 2.5 months to 16.2 years (mean 5.0 years). The test dose was administered orally and consisted of 0.5-4.5 micrograms of /sup 57/CoB12 (approximately 0.05 microCi), carmine powder, and 2 mg /sup 51/CrCl/sub 3/ (approximately 1.25 microCi) as the inabsorbable tracer. The wholebody radiation to a 1-year-old child averaged only 20 mrad. The stool and napkin was collected and homogenized bymore » addition of 300 ml chromium sulfuric acid. A 300-ml sample of the homogenized stool and napkin, as well as 300 ml chromium sulfuric acid (75% v/v) containing the standards, were counted in a broad-based well counter. The FAB12 determined by SSST employing the stool with the highest content of /sup 51/Cr (which corresponded to the most carmine-colored stool) correlated closely to the FAB12 based on complete stool collection (r = 0.98, n = 39, p less than 0.001). The reproducibility of FAB12 determined by SSST was assessed from double assays in 19 patients. For a mean value of 12%, the SD was 3%, which corresponded to a coefficient of variation (CV) of 25%. The excretion of /sup 57/Co and /sup 51/Cr in the urine was examined in six patients with moderate to severe mucosal damage and was found to be low.« less

  10. Direct Detection of Pharmaceuticals and Personal Care Products from Aqueous Samples with Thermally-Assisted Desorption Electrospray Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Campbell, Ian S.; Ton, Alain T.; Mulligan, Christopher C.

    2011-07-01

    An ambient mass spectrometric method based on desorption electrospray ionization (DESI) has been developed to allow rapid, direct analysis of contaminated water samples, and the technique was evaluated through analysis of a wide array of pharmaceutical and personal care product (PPCP) contaminants. Incorporating direct infusion of aqueous sample and thermal assistance into the source design has allowed low ppt detection limits for the target analytes in drinking water matrices. With this methodology, mass spectral information can be collected in less than 1 min, consuming ~100 μL of total sample. Quantitative ability was also demonstrated without the use of an internal standard, yielding decent linearity and reproducibility. Initial results suggest that this source configuration is resistant to carryover effects and robust towards multi-component samples. The rapid, continuous analysis afforded by this method offers advantages in terms of sample analysis time and throughput over traditional hyphenated mass spectrometric techniques.

  11. Direct detection of pharmaceuticals and personal care products from aqueous samples with thermally-assisted desorption electrospray ionization mass spectrometry.

    PubMed

    Campbell, Ian S; Ton, Alain T; Mulligan, Christopher C

    2011-07-01

    An ambient mass spectrometric method based on desorption electrospray ionization (DESI) has been developed to allow rapid, direct analysis of contaminated water samples, and the technique was evaluated through analysis of a wide array of pharmaceutical and personal care product (PPCP) contaminants. Incorporating direct infusion of aqueous sample and thermal assistance into the source design has allowed low ppt detection limits for the target analytes in drinking water matrices. With this methodology, mass spectral information can be collected in less than 1 min, consuming ~100 μL of total sample. Quantitative ability was also demonstrated without the use of an internal standard, yielding decent linearity and reproducibility. Initial results suggest that this source configuration is resistant to carryover effects and robust towards multi-component samples. The rapid, continuous analysis afforded by this method offers advantages in terms of sample analysis time and throughput over traditional hyphenated mass spectrometric techniques.

  12. Determination of arsenic in ambient water at sub-part-per-trillion levels by hydride generation Pd coated platform collection and GFAAS detection.

    PubMed

    Liang, L; Lazoff, S; Chan, C; Horvat, M; Woods, J S

    1998-11-01

    A method for trace determination of total arsenic in ambient waters is described. Arsenic is separated on-line from a large volume water sample by hydride generation and purging, pre-collected on a Pd coated pyrolytic platform cuvette using a simple and inexpensive system, and finally detected by GFAAS. Instrument parameters, hydride generation, transportation, and collection were optimized. The analytical behavior for major species including As(3+), As(5+), monomethyl As (MMA), and dimethyl As (DMA) were investigated individually. Problems arising from use of the system were discussed and eliminated. The necessity of sample digestion and an efficient digestion method were studied. Sample digestion for water with low organic content such as tap water and clean ground water and some clean surface water can be omitted. The method detection limit (MDL) is 0.3 ng l(-1) for a 25 ml water sample. Recoveries close to 100% with R.S.D.<5% can be easily achieved. Typical aqueous samples including tap, ground, lake, river, rain, sewage effluent, and saline water from different origins in the US, China, and Canada were collected and analyzed using ultra clean sampling and analysis techniques. The background levels of As in most water analyzed were established for the first time, and found to be far above the EPA's health effect criteria, 18 ng l(-1).

  13. The Indigo V Indian Ocean Expedition: a prototype for citizen microbial oceanography

    NASA Astrophysics Data System (ADS)

    Lauro, Federico; Senstius, Jacob; Cullen, Jay; Lauro, Rachelle; Neches, Russell; Grzymski, Joseph

    2014-05-01

    Microbial Oceanography has long been an extremely expensive discipline, requiring ship time for sample collection and thereby economically constraining the number of samples collected. This is especially true for under-sampled water bodies such as the Indian Ocean. Specialised scientific equipment only adds to the costs. Moreover, long term monitoring of microbial communities and large scale modelling of global biogeochemical cycles requires the collection of high-density data both temporally and spatially in a cost-effective way. Thousands of private ocean-going vessels are cruising around the world's oceans every day. We believe that a combination of new technologies, appropriate laboratory protocols and strategic operational partnerships will allow researchers to broaden the scope of participation in basic oceanographic research. This will be achieved by equipping sailing vessels with small, satcom-equipped sampling devices, user-friendly collection techniques and a 'pre-addressed-stamped-envelope' to send in the samples for analysis. We aim to prove that 'bigger' is not necessarily 'better' and the key to greater understanding of the world's oceans is to forge the way to easier and cheaper sample acquisition. The ultimate goal of the Indigo V Expedition is to create a working blue-print for 'citizen microbial oceanography'. We will present the preliminary outcomes of the first Indigo V expedition, from Capetown to Singapore, highlighting the challenges and opportunities of such endeavours.

  14. An advanced uracil DNA glycosylase-supplemented loop-mediated isothermal amplification (UDG-LAMP) technique used in the sensitive and specific detection of Cryptosporidium parvum, Cryptosporidium hominis, and Cryptosporidium meleagridis in AIDS patients.

    PubMed

    Fallahi, Shirzad; Moosavi, Seyedeh Fatemeh; Karimi, Azadeh; Chegeni, Ali Sharafi; Saki, Mohammad; Namdari, Parsa; Rashno, Mohammad Menati; Varzi, Ali Mohamad; Tarrahi, Mohammad Javad; Almasian, Mohammad

    2018-05-01

    The rapid and accurate detection of Cryptosporidium spp. is critically important for the prevention and timely treatment of cryptosporidiosis in AIDS patients (APs). This study was conducted to examine a UDG-LAMP technique for the first time to diagnose cryptosporidiosis in APs. After collecting demographic and clinical data, three stool samples were collected from the participants (120 volunteering APs). The microscopic examination of stained smears using the acid-fast method and the UDG-LAMP assay were performed for each sample. 10% of APs were infected with Cryptosporidium spp. The number of detected cryptosporidiosis cases using the acid-fast staining and UDG-LAMP methods were significantly different (P < 0.001). Diarrhea and weight loss were found to be significantly associated with cryptosporidiosis in patients (P < 0.05). The pretreatment of LAMP reagents with UDG successfully eliminated the likelihood of product re-amplification remaining from previous reactions. The UDG-LAMP technique could detect cryptosporidiosis in APs with high sensitivity and rapidity without carryover contamination. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Feasibility of a Fieldable Mass Spectrometer FY 2015 Year-end Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barinaga, Charles J.; Hager, George J.; Hoegg, Edward D.

    Currently, the International Atomic Energy Agency (IAEA) monitors the production of enriched uranium hexafluoride (UF 6) at declared facilities by collecting a few grams of product in sample tubes that are then sent to central laboratories for processing and isotope ratio analysis by thermal ionization mass spectrometry. Analysis of results may not be available for some time after collection. In addition, new shipping regulations will make it more difficult to transport this amount of UF 6 to a laboratory. The IAEA is interested in an isotope ratio technique for uranium in UF 6 that can be moved to and operatedmore » at the enrichment facility itself. This report covers the tasks and activities of the Feasibility of a Fieldable Mass Spectrometer Project for FY 2015, which investigates the feasibility of an in-field isotope ratio technique— the forward deployment of a technique to the non-laboratory situation of a protected room with power and heat at the facility of interest. A variety of nontraditional elemental ionization techniques were considered. It was determined that only two of these should be moved forward for testing with the candidate in-field mass spectrometer and with the adsorbed UF 6 sample types.« less

  16. Variation of Water Quality Parameters with Siltation Depth for River Ichamati Along International Border with Bangladesh Using Multivariate Statistical Techniques

    NASA Astrophysics Data System (ADS)

    Roy, P. K.; Pal, S.; Banerjee, G.; Biswas Roy, M.; Ray, D.; Majumder, A.

    2014-12-01

    River is considered as one of the main sources of freshwater all over the world. Hence analysis and maintenance of this water resource is globally considered a matter of major concern. This paper deals with the assessment of surface water quality of the Ichamati river using multivariate statistical techniques. Eight distinct surface water quality observation stations were located and samples were collected. For the samples collected statistical techniques were applied to the physico-chemical parameters and depth of siltation. In this paper cluster analysis is done to determine the relations between surface water quality and siltation depth of river Ichamati. Multiple regressions and mathematical equation modeling have been done to characterize surface water quality of Ichamati river on the basis of physico-chemical parameters. It was found that surface water quality of the downstream river was different from the water quality of the upstream. The analysis of the water quality parameters of the Ichamati river clearly indicate high pollution load on the river water which can be accounted to agricultural discharge, tidal effect and soil erosion. The results further reveal that with the increase in depth of siltation, water quality degraded.

  17. Comparison of three aerosol chemical characterization techniques utilizing PTR-ToF-MS: a study on freshly formed and aged biogenic SOA

    NASA Astrophysics Data System (ADS)

    Gkatzelis, Georgios I.; Tillmann, Ralf; Hohaus, Thorsten; Müller, Markus; Eichler, Philipp; Xu, Kang-Ming; Schlag, Patrick; Schmitt, Sebastian H.; Wegener, Robert; Kaminski, Martin; Holzinger, Rupert; Wisthaler, Armin; Kiendler-Scharr, Astrid

    2018-03-01

    An intercomparison of different aerosol chemical characterization techniques has been performed as part of a chamber study of biogenic secondary organic aerosol (BSOA) formation and aging at the atmosphere simulation chamber SAPHIR (Simulation of Atmospheric PHotochemistry In a large Reaction chamber). Three different aerosol sampling techniques - the aerosol collection module (ACM), the chemical analysis of aerosol online (CHARON) and the collection thermal-desorption unit (TD) were connected to proton transfer reaction time-of-flight mass spectrometers (PTR-ToF-MSs) to provide chemical characterization of the SOA. The techniques were compared among each other and to results from an aerosol mass spectrometer (AMS) and a scanning mobility particle sizer (SMPS). The experiments investigated SOA formation from the ozonolysis of β-pinene, limonene, a β-pinene-limonene mix and real plant emissions from Pinus sylvestris L. (Scots pine). The SOA was subsequently aged by photo-oxidation, except for limonene SOA, which was aged by NO3 oxidation. Despite significant differences in the aerosol collection and desorption methods of the PTR-based techniques, the determined chemical composition, i.e. the same major contributing signals, was found by all instruments for the different chemical systems studied. These signals could be attributed to known products expected from the oxidation of the examined monoterpenes. The sampling and desorption method of ACM and TD provided additional information on the volatility of individual compounds and showed relatively good agreement. Averaged over all experiments, the total aerosol mass recovery compared to an SMPS varied within 80 ± 10, 51 ± 5 and 27 ± 3 % for CHARON, ACM and TD, respectively. Comparison to the oxygen-to-carbon ratios (O : C) obtained by AMS showed that all PTR-based techniques observed lower O : C ratios, indicating a loss of molecular oxygen either during aerosol sampling or detection. The differences in total mass recovery and O : C between the three instruments resulted predominantly from differences in the field strength (E/N) in the drift tube reaction ionization chambers of the PTR-ToF-MS instruments and from dissimilarities in the collection/desorption of aerosols. Laboratory case studies showed that PTR-ToF-MS E/N conditions influenced fragmentation which resulted in water and further neutral fragment losses of the detected molecules. Since ACM and TD were operated in higher E/N than CHARON, this resulted in higher fragmentation, thus affecting primarily the detected oxygen and carbon content and therefore also the mass recovery. Overall, these techniques have been shown to provide valuable insight on the chemical characteristics of BSOA and can address unknown thermodynamic properties such as partitioning coefficient values and volatility patterns down to a compound-specific level.

  18. Procedures for Obtaining and Analyzing Writing Samples of School-Age Children and Adolescents.

    PubMed

    Price, Johanna R; Jackson, Sandra C

    2015-10-01

    Many students' writing skills are below grade-level expectations, and students with oral language difficulties are at particular risk for writing difficulties. Speech-language pathologists' (SLPs') expertise in language applies to both the oral and written modalities, yet evidence suggests that SLPs' confidence regarding writing assessment is low. Writing samples are a clinically useful, criterion-referenced assessment technique that is relevant to helping students satisfy writing-related requirements of the Common Core State Standards (National Governors Association Center for Best Practices and Council of Chief State School Officers, 2010a). This article provides recommendations for obtaining and analyzing students' writing samples. In this tutorial, the authors provide a comprehensive literature review of methods regarding (a) collection of writing samples from narrative, expository (informational/explanatory), and persuasive (argument) genres; (b) variables of writing performance that are useful to assess; and (c) manual and computer-aided techniques for analyzing writing samples. The authors relate their findings to expectations for writing skills expressed in the Common Core State Standards (National Governors Association Center for Best Practices & Council of Chief State School Officers, 2010a). SLPs can readily implement many techniques for obtaining and analyzing writing samples. The information in this article provides SLPs with recommendations for the use of writing samples and may help increase SLPs' confidence regarding written language assessment.

  19. Gunshot residue (GSR) analysis by single particle inductively coupled plasma mass spectrometry (spICP-MS).

    PubMed

    Heringer, Rodrigo D; Ranville, James F

    2018-05-25

    Single particle inductively coupled plasma mass spectrometry (spICP-MS) was investigated as a screening-level technique for the analysis and characterization of inorganic gunshot residue (IGSR) nanoparticles. spICP-MS works with undigested samples whereby nanoparticles (NPs) in a suspension are individually atomized and ionized as they reach the plasma, each resulting in a pulse of analyte ions that can be quantified. The method is rapid, and signals from hundreds of NPs can be collected in 1-2min per sample. The technique is quantitative for NP mass and number concentration when only one element (single element mode) is measured using a quadrupole MS. Likewise, a qualitative elemental fingerprint can be obtained for individual NPs when peak-hopping between two elements (dual element mode). For this proof of concept study, each shooter's hand was sampled with ultrapure water or swab to obtain NPs suspensions. Measurements of antimony, barium, and lead were performed using both analysis modes. With no sample preparation and fully automated sample introduction, it is possible to analyze more than 100 samples in a day. Results show that this technique opens a new perspective for future research on GSR sample identification and characterization and can complement SEM/EDX analysis. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Encouragement of Early Academic Skills at Home during Early Childhood Period: Validity and Reliability Study of the EASYC Scale

    ERIC Educational Resources Information Center

    Kara, H. Gözde Ertürk; Çoksoyluer, Seyda Kiliç

    2017-01-01

    The current study aims to perform the adaptation of the Encouragement of Academic Skills of Young Children (EASYC) Scale into Turkish. The study group was determined by means of the convenience sampling technique. A total of 124 students aged at 48-84 months were included in the sampling of the study. The data collection tools of the study are the…

  1. Electrical characterization and comparison of CIGS solar cells made with different structures and fabrication techniques

    DOE PAGES

    Garris, Rebekah L.; Johnston, Steven; Li, Jian V.; ...

    2017-08-31

    In a previous study, we reported on Cu(In,Ga)Se2-based (CIGS) solar cell samples collected from different research laboratories and industrial companies with the purpose of understanding the range of CIGS materials that can lead to high-quality and high-efficiency solar panels. Here, we report on electrical measurements of those same samples. Electron-beam induced current and time-resolved photoluminescence (TRPL) gave insights about the collection probability and the lifetime of carriers generated in each absorber. Capacitance and drive-level capacitance profiling revealed nonuniformity in carrier-density profiles. Admittance spectroscopy revealed small activation energies (= 0.03 eV) indicative of the inversion strength, larger activation energies (> 0.1more » eV) reflective of thermal activation of absorber conductivity and a deeper defect level. Deep-level transient spectroscopy (DLTS) probed deep hole-trapping defects and showed that all samples in this study had a majority-carrier defect with activation energy between 0.3 eV and 0.9 eV. Optical-DLTS revealed deep electron-trapping defects in several of the CIGS samples. This work focused on revealing similarities and differences between high-quality CIGS solar cells made with various structures and fabrication techniques.« less

  2. Electrical characterization and comparison of CIGS solar cells made with different structures and fabrication techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garris, Rebekah L.; Johnston, Steven; Li, Jian V.

    In a previous study, we reported on Cu(In,Ga)Se2-based (CIGS) solar cell samples collected from different research laboratories and industrial companies with the purpose of understanding the range of CIGS materials that can lead to high-quality and high-efficiency solar panels. Here, we report on electrical measurements of those same samples. Electron-beam induced current and time-resolved photoluminescence (TRPL) gave insights about the collection probability and the lifetime of carriers generated in each absorber. Capacitance and drive-level capacitance profiling revealed nonuniformity in carrier-density profiles. Admittance spectroscopy revealed small activation energies (= 0.03 eV) indicative of the inversion strength, larger activation energies (> 0.1more » eV) reflective of thermal activation of absorber conductivity and a deeper defect level. Deep-level transient spectroscopy (DLTS) probed deep hole-trapping defects and showed that all samples in this study had a majority-carrier defect with activation energy between 0.3 eV and 0.9 eV. Optical-DLTS revealed deep electron-trapping defects in several of the CIGS samples. This work focused on revealing similarities and differences between high-quality CIGS solar cells made with various structures and fabrication techniques.« less

  3. Bladder cancer diagnosis during cystoscopy using Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Grimbergen, M. C. M.; van Swol, C. F. P.; Draga, R. O. P.; van Diest, P.; Verdaasdonk, R. M.; Stone, N.; Bosch, J. H. L. R.

    2009-02-01

    Raman spectroscopy is an optical technique that can be used to obtain specific molecular information of biological tissues. It has been used successfully to differentiate normal and pre-malignant tissue in many organs. The goal of this study is to determine the possibility to distinguish normal tissue from bladder cancer using this system. The endoscopic Raman system consists of a 6 Fr endoscopic probe connected to a 785nm diode laser and a spectral recording system. A total of 107 tissue samples were obtained from 54 patients with known bladder cancer during transurethral tumor resection. Immediately after surgical removal the samples were placed under the Raman probe and spectra were collected and stored for further analysis. The collected spectra were analyzed using multivariate statistical methods. In total 2949 Raman spectra were recorded ex vivo from cold cup biopsy samples with 2 seconds integration time. A multivariate algorithm allowed differentiation of normal and malignant tissue with a sensitivity and specificity of 78,5% and 78,9% respectively. The results show the possibility of discerning normal from malignant bladder tissue by means of Raman spectroscopy using a small fiber based system. Despite the low number of samples the results indicate that it might be possible to use this technique to grade identified bladder wall lesions during endoscopy.

  4. Arsenic health risk assessment in drinking water and source apportionment using multivariate statistical techniques in Kohistan region, northern Pakistan.

    PubMed

    Muhammad, Said; Tahir Shah, M; Khan, Sardar

    2010-10-01

    The present study was conducted in Kohistan region, where mafic and ultramafic rocks (Kohistan island arc and Indus suture zone) and metasedimentary rocks (Indian plate) are exposed. Water samples were collected from the springs, streams and Indus river and analyzed for physical parameters, anions, cations and arsenic (As(3+), As(5+) and arsenic total). The water quality in Kohistan region was evaluated by comparing the physio-chemical parameters with permissible limits set by Pakistan environmental protection agency and world health organization. Most of the studied parameters were found within their respective permissible limits. However in some samples, the iron and arsenic concentrations exceeded their permissible limits. For health risk assessment of arsenic, the average daily dose, hazards quotient (HQ) and cancer risk were calculated by using statistical formulas. The values of HQ were found >1 in the samples collected from Jabba, Dubair, while HQ values were <1 in rest of the samples. This level of contamination should have low chronic risk and medium cancer risk when compared with US EPA guidelines. Furthermore, the inter-dependence of physio-chemical parameters and pollution load was also calculated by using multivariate statistical techniques like one-way ANOVA, correlation analysis, regression analysis, cluster analysis and principle component analysis. Copyright © 2010 Elsevier Ltd. All rights reserved.

  5. RNA sample preparation applied to gene expression profiling for the horse biological passport.

    PubMed

    Bailly-Chouriberry, Ludovic; Baudoin, Florent; Cormant, Florence; Glavieux, Yohan; Loup, Benoit; Garcia, Patrice; Popot, Marie-Agnès; Bonnaire, Yves

    2017-09-01

    The improvement of doping control is an ongoing race. Techniques to fight doping are usually based on the direct detection of drugs or their metabolites by analytical methods such as chromatography hyphenated to mass spectrometry after ad hoc sample preparation. Nowadays, omic methods constitute an attractive development and advances have been achieved particularly by application of molecular biology tools for detection of anabolic androgenic steroids (AAS), erythropoiesis-stimulating agent (ESA), or to control human growth hormone misuses. These interesting results across different animal species have suggested that modification of gene expression offers promising new methods of improving the window of detection of banned substances by targeting their effects on blood cell gene expression. In this context, the present study describes the possibility of using a modified version of the dedicated Human IVD (in vitro Diagnostics) PAXgene® Blood RNA Kit for horse gene expression analysis in blood collected on PAXgene® tubes applied to the horse biological passport. The commercial kit was only approved for human blood samples and has required an optimization of specific technical requirements for equine blood samples. Improvements and recommendations were achieved for sample collection, storage and RNA extraction procedure. Following these developments, RNA yield and quality were demonstrated to be suitable for downstream gene expression analysis by qPCR techniques. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Understanding the behavior of Giardia and Cryptosporidium in an urban watershed: Explanation and application of techniques to collect and evaluate monitoring data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crockett, C.S.; Haas, C.N.

    1996-11-01

    Due to current proposed regulations requiring monitoring for protozoans and demonstration of adequate protozoan removal depending on source water concentrations detected, many utilities are considering or are engaged in protozoan monitoring activities within their watershed so that proper watershed management and treatment modifications can reduce their impact on drinking water safety and quality. However, due to the difficulties associated with the current analytical methods and sample collection many sampling efforts collect data that cannot be interpreted or lack the tools to interpret the information obtained. Therefore, it is necessary to determine how to develop an effective sampling program tailored tomore » a utility`s specific needs to provide interpretable data and develop tools for evaluating such data. The following case study describes the process in which a utility learned how to collect and interpret monitoring data for their specific needs and provides concepts and tools which other utilities can use to aid in their own macro and microwatershed management efforts.« less

  7. Measurements of Light Absorbing Particles on Tropical South American Glaciers

    NASA Astrophysics Data System (ADS)

    Schmitt, C. G.; All, J.; Schwarz, J. P.; Arnott, W. P.; Warthon, J.; Andrade, M.; Celestian, A. J.; Hoffmann, D.; Cole, R. J.; Lapham, E.; Horodyskyj, U. N.; Froyd, K. D.; Liao, J.

    2014-12-01

    Glaciers in the tropical Andes have been losing mass rapidly in recent decades. In addition to the documented increase in temperature, increases in light absorbing particulates deposited on glaciers could be contributing to the observed glacier loss. Here we present results of measurements of light absorbing particles from glaciers in Peru and Bolivia. Samples have been collected by American Climber Science Program volunteers and scientists at altitudes up to 6770 meters. Collected snow samples were melted and filtered in the field. A new inexpensive technique, the Light Absorption Heating Method (LAHM) has been developed for analysis of light absorbing particles collected on filters. Results from LAHM analysis are calibrated using filters with known amounts of fullerene soot, a common industrial surrogate for black carbon (BC). For snow samples collected at the same field location LAHM analysis and measurements from the Single Particle Soot Photometer (SP2) instrument are well correlated (r2 = 0.92). Co-located SP2 and LAHM filter analysis suggest that BC could be the dominant absorbing component of the light absorbing particles in some areas.

  8. A passive ozone sampler based on a reaction with nitrite.

    PubMed

    Koutrakis, P; Wolfson, J M; Bunyaviroch, A; Froehlich, S

    1994-02-01

    Standard ozone monitoring techniques utilize large, heavy, and expensive instruments that are not easily adapted for personal or microenvironmental monitoring. For large-scale monitoring projects that examine spatial variations of a pollutant and human exposure assessments, passive sampling devices can provide the methodology to meet monitoring and statistical goals. Recently, we developed a coated filter for ozone collection that we used in a commercially available passive sampling device. Successful preliminary results merited further validation tests, which are presented in this report. The passive ozone sampler used in field and laboratory experiments consists of a badge clip supporting a barrel-shaped body that contains two coated glass fiber filters. The principle component of the coating is nitrite ion, which in the presence of ozone is oxidized to nitrate ion on the filter medium (NO2- + O3 produces NO3- + O2). After sample collection, the filters were extracted with ultrapure water and analyzed for nitrate ion by ion chromatography. The results from laboratory and field validation tests indicated excellent agreement between the passive method and standard ozone monitoring techniques. We determined that relative humidity (ranging from 10% to 80%) and temperature (ranging from 0 degrees C to 40 degrees C) at typical ambient ozone levels (40 to 100 parts per billion) do not influence sampler performance. Face velocity and sampler orientation with respect to wind direction were found to affect the sampler's collection rate of ozone. Using a protective cup, which acts as both a wind screen and a rain cover, we were able to obtain a constant collection rate over a wide range of wind speeds.

  9. Genetic diversity analysis of Jatropha curcas L. (Euphorbiaceae) based on methylation-sensitive amplification polymorphism.

    PubMed

    Kanchanaketu, T; Sangduen, N; Toojinda, T; Hongtrakul, V

    2012-04-13

    Genetic analysis of 56 samples of Jatropha curcas L. collected from Thailand and other countries was performed using the methylation-sensitive amplification polymorphism (MSAP) technique. Nine primer combinations were used to generate MSAP fingerprints. When the data were interpreted as amplified fragment length polymorphism (AFLP) markers, 471 markers were scored. All 56 samples were classified into three major groups: γ-irradiated, non-toxic and toxic accessions. Genetic similarity among the samples was extremely high, ranging from 0.95 to 1.00, which indicated very low genetic diversity in this species. The MSAP fingerprint was further analyzed for DNA methylation polymorphisms. The results revealed differences in the DNA methylation level among the samples. However, the samples collected from saline areas and some species hybrids showed specific DNA methylation patterns. AFLP data were used, together with methylation-sensitive AFLP (MS-AFLP) data, to construct a phylogenetic tree, resulting in higher efficiency to distinguish the samples. This combined analysis separated samples previously grouped in the AFLP analysis. This analysis also distinguished some hybrids. Principal component analysis was also performed; the results confirmed the separation in the phylogenetic tree. Some polymorphic bands, involving both nucleotide and DNA methylation polymorphism, that differed between toxic and non-toxic samples were identified, cloned and sequenced. BLAST analysis of these fragments revealed differences in DNA methylation in some known genes and nucleotide polymorphism in chloroplast DNA. We conclude that MSAP is a powerful technique for the study of genetic diversity for organisms that have a narrow genetic base.

  10. Actinide bioimaging in tissues: Comparison of emulsion and solid track autoradiography techniques with the iQID camera

    PubMed Central

    Miller, Brian W.; Van der Meeren, Anne; Tazrart, Anissa; Angulo, Jaime F.; Griffiths, Nina M.

    2017-01-01

    This work presents a comparison of three autoradiography techniques for imaging biological samples contaminated with actinides: emulsion-based, plastic-based autoradiography and a quantitative digital technique, the iQID camera, based on the numerical analysis of light from a scintillator screen. In radiation toxicology it has been important to develop means of imaging actinide distribution in tissues as these radionuclides may be heterogeneously distributed within and between tissues after internal contamination. Actinide distribution determines which cells are exposed to alpha radiation and is thus potentially critical for assessing absorbed dose. The comparison was carried out by generating autoradiographs of the same biological samples contaminated with actinides with the three autoradiography techniques. These samples were cell preparations or tissue sections collected from animals contaminated with different physico-chemical forms of actinides. The autoradiograph characteristics and the performances of the techniques were evaluated and discussed mainly in terms of acquisition process, activity distribution patterns, spatial resolution and feasibility of activity quantification. The obtained autoradiographs presented similar actinide distribution at low magnification. Out of the three techniques, emulsion autoradiography is the only one to provide a highly-resolved image of the actinide distribution inherently superimposed on the biological sample. Emulsion autoradiography is hence best interpreted at higher magnifications. However, this technique is destructive for the biological sample. Both emulsion- and plastic-based autoradiography record alpha tracks and thus enabled the differentiation between ionized forms of actinides and oxide particles. This feature can help in the evaluation of decorporation therapy efficacy. The most recent technique, the iQID camera, presents several additional features: real-time imaging, separate imaging of alpha particles and gamma rays, and alpha activity quantification. The comparison of these three autoradiography techniques showed that they are complementary and the choice of the technique depends on the purpose of the imaging experiment. PMID:29023595

  11. Determination of Se in soil samples using the proton induced X-ray emission technique

    NASA Astrophysics Data System (ADS)

    Cruvinel, Paulo E.; Flocchini, Robert G.

    1993-04-01

    An alternative method for the direct determination of total Se in soil samples is presented. A large number of trace elements is present in soil at concentration values in the range of part per billion and tenths of parts of million. The most common are the trace elements of Al, Si, K, Ca, Ti, V, Cr, Fe, Cu, Zn, Br, Rb, Mo, Cd and Pb. As for biological samples many of these elements are of great importance for the nutrition of plants, while others are toxic and others have an unknown role. Selenium is an essential micronutrient for humans and animals but it is also known that in certain areas Se deficiency or toxicity has caused endemic disease to livestock and humans through the soil-plant-animal linkage. In this work the suitability of the proton induced X-ray emission (PIXE) technique as a fast and nondestructive technique useful to measure total the Se content in soil samples is demonstrated. To validate the results a comparison of data collected using the conventional atomic absorption spectrophotometry (AAS) method was performed.

  12. A New Method for Estimating Bacterial Abundances in Natural Samples using Sublimation

    NASA Technical Reports Server (NTRS)

    Glavin, Daniel P.; Cleaves, H. James; Schubert, Michael; Aubrey, Andrew; Bada, Jeffrey L.

    2004-01-01

    We have developed a new method based on the sublimation of adenine from Escherichia coli to estimate bacterial cell counts in natural samples. To demonstrate this technique, several types of natural samples including beach sand, seawater, deep-sea sediment, and two soil samples from the Atacama Desert were heated to a temperature of 500 C for several seconds under reduced pressure. The sublimate was collected on a cold finger and the amount of adenine released from the samples then determined by high performance liquid chromatography (HPLC) with UV absorbance detection. Based on the total amount of adenine recovered from DNA and RNA in these samples, we estimated bacterial cell counts ranging from approx. l0(exp 5) to l0(exp 9) E. coli cell equivalents per gram. For most of these samples, the sublimation based cell counts were in agreement with total bacterial counts obtained by traditional DAPI staining. The simplicity and robustness of the sublimation technique compared to the DAPI staining method makes this approach particularly attractive for use by spacecraft instrumentation. NASA is currently planning to send a lander to Mars in 2009 in order to assess whether or not organic compounds, especially those that might be associated with life, are present in Martian surface samples. Based on our analyses of the Atacama Desert soil samples, several million bacterial cells per gam of Martian soil should be detectable using this sublimation technique.

  13. Genetic analysis of Asian longhorned beetle populations from Chicago, New York, and China using the RAPD technique

    Treesearch

    James M. Slavicek; Patricia De Graff

    2003-01-01

    Anoplophora glabripennis samples were collected in the Ravenswood area of Chicago, near the Mt. Zion cemetery in Queens, New York (provided by Leah Bauer) and the Gansu Province in northwest China (provided by Leah Bauer).

  14. Guidelines for collection and field analysis of water-quality samples from streams in Texas

    USGS Publications Warehouse

    Wells, F.C.; Gibbons, W.J.; Dorsey, M.E.

    1990-01-01

    Analyses for unstable constituents or properties are by necessity performed in the field. This manual addresses analytical techniques and quality assurance for: (1) Water temperature; (2) specific conductance; (3) pH; (4) alkalinity; (5) dissolved oxygen; and (6) bacteria.

  15. Apparatus to collect, classify, concentrate, and characterize gas-borne particles

    DOEpatents

    Rader, Daniel J.; Torczynski, John R.; Wally, Karl; Brockmann, John E.

    2002-01-01

    An aerosol lab-on-a-chip (ALOC) integrates one or more of a variety of aerosol collection, classification, concentration (enrichment), and characterization processes onto a single substrate or layered stack of such substrates. By taking advantage of modern micro-machining capabilities, an entire suite of discrete laboratory aerosol handling and characterization techniques can be combined in a single portable device that can provide a wealth of data on the aerosol being sampled. The ALOC offers parallel characterization techniques and close proximity of the various characterization modules helps ensure that the same aerosol is available to all devices (dramatically reducing sampling and transport errors). Micro-machine fabrication of the ALOC significantly reduces unit costs relative to existing technology, and enables the fabrication of small, portable ALOC devices, as well as the potential for rugged design to allow operation in harsh environments. Miniaturization also offers the potential of working with smaller particle sizes and lower pressure drops (leading to reduction of power consumption).

  16. Proposed method of hydrogeochemical exploration for salt deposits using ClBr ratios, Eastern Province, Kingdom of Saudi Arabia

    USGS Publications Warehouse

    Smith, C.L.

    1991-01-01

    Despite the value of the salt (NaCl) and brine used by the chemical industry, geochemical prospecting techniques are not customarily employed in the search for these raw materials. In this study, Br geochemistry is used as the basis for a proposed hydrogeochemical prospecting technique that was designed to search for shallow halite beds in the Eastern Province of the Kingdom of Saudi Arabia. Near-surface brine samples were collected at Sabkhah Jayb Uwayyid, both directly above and distant from a buried salt bed. Brine samples collected both directly above and offset to the north-west of the salt bed had ClBr ratios > 8000. The regional background ClBr ratio of fresh nonmarime ground water is ???300. The large range in ClBr ratios and the association of high ClBr ratios with the buried salt body suggest that the ratio can be useful in hydrogeochemical prospecting for sibakh-associated, shallow salt bodies. ?? 1991.

  17. Comparison of vaginal microbiota sampling techniques: cytobrush versus swab.

    PubMed

    Mitra, Anita; MacIntyre, David A; Mahajan, Vishakha; Lee, Yun S; Smith, Ann; Marchesi, Julian R; Lyons, Deirdre; Bennett, Phillip R; Kyrgiou, Maria

    2017-08-29

    Evidence suggests the vaginal microbiota (VM) may influence risk of persistent Human Papillomavirus (HPV) infection and cervical carcinogenesis. Established cytology biobanks, typically collected with a cytobrush, constitute a unique resource to study such associations longitudinally. It is plausible that compared to rayon swabs; the most commonly used sampling devices, cytobrushes may disrupt biofilms leading to variation in VM composition. Cervico-vaginal samples were collected with cytobrush and rayon swabs from 30 women with high-grade cervical precancer. Quantitative PCR was used to compare bacterial load and Illumina MiSeq sequencing of the V1-V3 regions of the 16S rRNA gene used to compare VM composition. Cytobrushes collected a higher total bacterial load. Relative abundance of bacterial species was highly comparable between sampling devices (R 2  = 0.993). However, in women with a Lactobacillus-depleted, high-diversity VM, significantly less correlation in relative species abundance was observed between devices when compared to those with a Lactobacillus species-dominant VM (p = 0.0049). Cytobrush and swab sampling provide a comparable VM composition. In a small proportion of cases the cytobrush was able to detect underlying high-diversity community structure, not realized with swab sampling. This study highlights the need to consider sampling devices as potential confounders when comparing multiple studies and datasets.

  18. Analytical procedures for the determination of fuel combustion products, anti-corrosive compounds, and de-icing compounds in airport runoff water samples.

    PubMed

    Sulej, Anna Maria; Polkowska, Żaneta; Astel, Aleksander; Namieśnik, Jacek

    2013-12-15

    The purpose of this study is to propose and evaluate new procedures for determination of fuel combustion products, anti-corrosive and de-icing compounds in runoff water samples collected from the airports located in different regions and characterized by different levels of the activity expressed by the number of flights and the number of passengers (per year). The most difficult step in the analytical procedure used for the determination of PAHs, benzotriazoles and glycols is sample preparation stage, due to diverse matrix composition, the possibility of interference associated with the presence of components with similar physicochemical properties. In this study, five different versions of sample preparation using extraction techniques, such as: LLE and SPE, were tested. In all examined runoff water samples collected from the airports, the presence of PAH compounds and glycols was observed. In majority of the samples, BT compounds were determined. Runoff water samples collected from the areas of Polish and British international airports as well as local airports had similar qualitative composition, but quantitative composition of the analytes was very diverse. New and validated analytical methodologies ensure that the necessary information for assessing the negative impact of airport activities on the environment can be obtained. © 2013 Elsevier B.V. All rights reserved.

  19. Quality of stormwater runoff discharged from Massachusetts highways, 2005-07

    USGS Publications Warehouse

    Smith, Kirk P.; Granato, Gregory E.

    2010-01-01

    The U.S. Geological Survey (USGS), in cooperation with U.S. Department of Transportation Federal Highway Administration and the Massachusetts Department of Transportation, conducted a field study from September 2005 through September 2007 to characterize the quality of highway runoff for a wide range of constituents. The highways studied had annual average daily traffic (AADT) volumes from about 3,000 to more than 190,000 vehicles per day. Highway-monitoring stations were installed at 12 locations in Massachusetts on 8 highways. The 12 monitoring stations were subdivided into 4 primary, 4 secondary, and 4 test stations. Each site contained a 100-percent impervious drainage area that included two or more catch basins sharing a common outflow pipe. Paired primary and secondary stations were located within a few miles of each other on a limited-access section of the same highway. Most of the data were collected at the primary and secondary stations, which were located on four principal highways (Route 119, Route 2, Interstate 495, and Interstate 95). The secondary stations were operated simultaneously with the primary stations for at least a year. Data from the four test stations (Route 8, Interstate 195, Interstate 190, and Interstate 93) were used to determine the transferability of the data collected from the principal highways to other highways characterized by different construction techniques, land use, and geography. Automatic-monitoring techniques were used to collect composite samples of highway runoff and make continuous measurements of several physical characteristics. Flowweighted samples of highway runoff were collected automatically during approximately 140 rain and mixed rain, sleet, and snowstorms. These samples were analyzed for physical characteristics and concentrations of 6 dissolved major ions, total nutrients, 8 total-recoverable metals, suspended sediment, and 85 semivolatile organic compounds (SVOCs), which include priority polyaromatic hydrocarbons (PAHs), phthalate esters, and other anthropogenic or naturally occurring organic compounds. The distribution of particle size of suspended sediment also was determined for composite samples of highway runoff. Samples of highway runoff were collected year round and under various dry antecedent conditions throughout the 2-year sampling period. In addition to samples of highway runoff, supplemental samples also were collected of sediment in highway runoff, background soils, berm materials, maintenance sands, deicing compounds, and vegetation matter. These additional samples were collected near or on the highways to support data analysis. There were few statistically significant differences between populations of constituent concentrations in samples from the primary and secondary stations on the same principal highways (Mann-Whitney test, 95-percent confidence level). Similarly, there were few statistically significant differences between populations of constituent concentrations for the four principal highways (data from the paired primary and secondary stations for each principal highway) and populations for test stations with similar AADT volumes. Exceptions to this include several total-recoverable metals for stations on Route 2 and Interstate 195 (highways with moderate AADT volumes), and for stations on Interstate 95 and Interstate 93 (highways with high AADT volumes). Supplemental data collected during this study indicate that many of these differences may be explained by the quantity, as well as the quality, of the sediment in samples of highway runoff. Nonparametric statistical methods also were used to test for differences between populations of sample constituent concentrations among the four principal highways that differed mainly in traffic volume. These results indicate that there were few statistically significant differences (Mann-Whitney test, 95-percent confidence level) for populations of concentrations of most total-recoverable metals

  20. Collection, transport and general processing of clinical specimens in Microbiology laboratory.

    PubMed

    Sánchez-Romero, M Isabel; García-Lechuz Moya, Juan Manuel; González López, Juan José; Orta Mira, Nieves

    2018-02-06

    The interpretation and the accuracy of the microbiological results still depend to a great extent on the quality of the samples and their processing within the Microbiology laboratory. The type of specimen, the appropriate time to obtain the sample, the way of sampling, the storage and transport are critical points in the diagnostic process. The availability of new laboratory techniques for unusual pathogens, makes necessary the review and update of all the steps involved in the processing of the samples. Nowadays, the laboratory automation and the availability of rapid techniques allow the precision and turn-around time necessary to help the clinicians in the decision making. In order to be efficient, it is very important to obtain clinical information to use the best diagnostic tools. Copyright © 2018 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  1. Guidelines for the processing and quality assurance of benthic invertebrate samples collected as part of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Cuffney, T.F.; Gurtz, M.E.; Meador, M.R.

    1993-01-01

    Benthic invertebrate samples are collected as part of the U.S. Geological Survey's National Water-Quality Assessment Program. This is a perennial, multidisciplinary program that integrates biological, physical, and chemical indicators of water quality to evaluate status and trends and to develop an understanding of the factors controlling observed water quality. The Program examines water quality in 60 study units (coupled ground- and surface-water systems) that encompass most of the conterminous United States and parts of Alaska and Hawaii. Study-unit teams collect and process qualitative and semi-quantitative invertebrate samples according to standardized procedures. These samples are processed (elutriated and subsampled) in the field to produce as many as four sample components: large-rare, main-body, elutriate, and split. Each sample component is preserved in 10-percent formalin, and two components, large-rare and main-body, are sent to contract laboratories for further processing. The large-rare component is composed of large invertebrates that are removed from the sample matrix during field processing and placed in one or more containers. The main-body sample component consists of the remaining sample materials (sediment, detritus, and invertebrates) and is subsampled in the field to achieve a volume of 750 milliliters or less. The remaining two sample components, elutriate and split, are used for quality-assurance and quality-control purposes. Contract laboratories are used to identify and quantify invertebrates from the large-rare and main-body sample components according to the procedures and guidelines specified within this document. These guidelines allow the use of subsampling techniques to reduce the volume of sample material processed and to facilitate identifications. These processing procedures and techniques may be modified if the modifications provide equal or greater levels of accuracy and precision. The intent of sample processing is to determine the quantity of each taxon present in the semi-quantitative samples or to list the taxa present in qualitative samples. The processing guidelines provide standardized laboratory forms, sample labels, detailed sample processing flow charts, standardized format for electronic data, quality-assurance procedures and checks, sample tracking standards, and target levels for taxonomic determinations. The contract laboratory (1) is responsible for identifications and quantifications, (2) constructs reference collections, (3) provides data in hard copy and electronic forms, (4) follows specified quality-assurance and quality-control procedures, and (5) returns all processed and unprocessed portions of the samples. The U.S. Geological Survey's Quality Management Group maintains a Biological Quality-Assurance Unit, located at the National Water-Quality Laboratory, Arvada, Colorado, to oversee the use of contract laboratories and ensure the quality of data obtained from these laboratories according to the guidelines established in this document. This unit establishes contract specifications, reviews contractor performance (timeliness, accuracy, and consistency), enters data into the National Water Information System-II data base, maintains in-house reference collections, deposits voucher specimens in outside museums, and interacts with taxonomic experts within and outside the U.S. Geological Survey. This unit also modifies the existing sample processing and quality-assurance guidelines, establishes criteria and testing procedures for qualifying potential contract laboratories, identifies qualified taxonomic experts, and establishes voucher collections.

  2. The use of FT-IR reflection-absorbance spectroscopy to study photochemical degradation of polymeric coatings on mirrors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Webb, J.D.; Chughtai, A.R.; Czanderna, A.W.

    1981-10-01

    A technique is presented for in situ study of degradative changes in polymeric coatings on metallic substrates. The technique uses a controlled environment chamber in conjunction with a Fourier-transform infrared (FT-IR) spectrophotometer. The chamber design permits collection of IR reflection-absorbance spectra from a sample undergoing exposure to controlled ultraviolet (UV) radiation, gas mixtures, and temperatures. Initial data presented confirm the ability of the technique to provide information regarding the bulk photochemistry of bisphenol-A polycarbonate coatings on gold and aluminum substrates. Refinements of this technique should allow a detailed kinetic study of degradative reactions at the polymer/metal interface.

  3. Use of FT-IR reflection-absorbance spectroscopy to study photochemical degradation of polymeric coatings on mirrors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Webb, J D; Schissel, P; Czanderna, A W

    1981-01-01

    A technique is presented for in situ study of degradative changes in polymeric coatings on metallic substrates. The technique uses a controlled environment chamber in conjunction with a Fourier-transform infrared (FT-IR) spectrophotometer. The chamber design permits collection of IR reflection-absorbance spectra from a sample undergoing exposure to controlled ultraviolet (uv) radiation, gas mixtures, and temperatures. Initial data presented confirm the ability of the technique to provide information regarding the bulk photochemistry of bisphenol-A polycarbonate coatings on gold and aluminum substrates. Refinements of this technique should allow a detailed kinetic study of degradative reactions at the polymer/metal interface.

  4. Development and application of non-invasive biomarkers for carcinogen-DNA adduct analysis in occupationally exposed populations.

    PubMed

    Talaska, G; Cudnik, J; Jaeger, M; Rothman, N; Hayes, R; Bhatnagar, V J; Kayshup, S J

    1996-07-17

    Biological monitoring of exposures to carcinogenic compounds in the workplace can be a valuable adjunct to environmental sampling and occupational medicine. Carcinogen-DNA adduct analysis has promise as a biomarker of effective dose if target organ samples can be obtained non-invasively. We have developed non-invasive techniques using exfoliated urothelial and bronchial cells collected in urine and sputum, respectively. First morning urine samples were collected from 33 workers exposed to benzidine or benzidine-based dyes and controls matched for age, education, and smoking status. Sufficient DNA for 32P-postlabelling analysis was obtained from every sample. Mean levels of a specific DNA adduct (which co-chromatographed with standard characterized by MS) were elevated significantly in the benzidine-exposed workers relative to controls. In addition, workers exposed to benzidine had higher adduct levels than those exposed to benzidine-based dyes. This study demonstrates the usefulness of these non-invasive techniques for exposure/effect assessment. To be useful in occupational studies, biomarkers must also be sensitive to exposure interventions. We have conducted topical application studies of used gasoline engine oils in mice and found that the levels of carcinogen-DNA adducts in skin and lung can be significantly lowered if skin cleaning is conducted in a timely manner. The combination of useful, non-invasive techniques to monitor exposure and effect and industrial hygiene interventions can be used to detect and prevent exposures to a wide range of carcinogens including those found in used gasoline engine oils and jet exhausts.

  5. Comparing efficiency of American Fisheries Society standard snorkeling techniques to environmental DNA sampling techniques

    USGS Publications Warehouse

    Ulibarri, Roy M.; Bonar, Scott A.; Rees, Christopher B.; Amberg, Jon J.; Ladell, Bridget; Jackson, Craig

    2017-01-01

    Analysis of environmental DNA (eDNA) is an emerging technique used to detect aquatic species through water sampling and the extraction of biological material for amplification. Our study compared the efficacy of eDNA methodology to American Fisheries Society (AFS) standard snorkeling surveys with regard to detecting the presence of rare fish species. Knowing which method is more efficient at detecting target species will help managers to determine the best way to sample when both traditional sampling methods and eDNA sampling are available. Our study site included three Navajo Nation streams that contained Navajo Nation Genetic Subunit Bluehead Suckers Catostomus discobolus and Zuni Bluehead Suckers C. discobolus yarrowi. We first divided the entire wetted area of streams into consecutive 100-m reaches and then systematically selected 10 reaches/stream for snorkel and eDNA surveys. Surface water samples were taken in 10-m sections within each 100-m reach, while fish presence was noted via snorkeling in each 10-m section. Quantitative PCR was run on each individual water sample in quadruplicate to test for the presence or absence of the target species. With eDNA sampling techniques, we were able to positively detect both species in two out of the three streams. Snorkeling resulted in positive detection of both species in all three streams. In streams where the target species were detected with eDNA sampling, snorkeling detected fish at 11–29 sites/stream, whereas eDNA detected fish at 3–12 sites/stream. Our results suggest that AFS standard snorkeling is more effective than eDNA for detecting target fish species. To improve our eDNA procedures, the amount of water collected and tested should be increased. Additionally, filtering water on-site may improve eDNA techniques for detecting fish. Future research should focus on standardization of eDNA sampling to provide a widely operational sampling tool.

  6. Insights in groundwater organic matter from Liquid Chromatography-Organic Carbon Detection

    NASA Astrophysics Data System (ADS)

    Rutlidge, H.; Oudone, P.; McDonough, L.; Andersen, M. S.; Baker, A.; Meredith, K.; O'Carroll, D. M.

    2017-12-01

    Understanding the processes that control the concentration and characteristics of organic matter in groundwater has important implications for the terrestrial global carbon budget. Liquid Chromatography - Organic Carbon Detection (LC-OCD) is a size-exclusion based chromatography technique that separates the organic carbon into molecular weight size fractions of biopolymers, humic substances, building blocks (degradation products of humic substances), low molecular weight acids and low molecular weight neutrals. Groundwater and surface water samples were collected from a range of locations in Australia representing different surface soil, land cover, recharge type and hydrological properties. At one site hyporheic zone samples were also collected from beneath a stream. The results showed a general decrease in the aromaticity and molecular weight indices going from surface water, hyporheic downwelling and groundwater samples. The aquifer substrate also affected the organic composition. For example, groundwater samples collected from a zone of fractured rock showed a relative decrease in the proportion of humic substances, suggestive of sorption or degradation of humic substances. This work demonstrates the potential for using LC-OCD in elucidating the processes that control the concentration and characteristics of organic matter in groundwater.

  7. Midstream clean-catch urine collection in newborns: a randomized controlled study.

    PubMed

    Altuntas, Nilgun; Tayfur, Asli Celebi; Kocak, Mesut; Razi, Hasan Cem; Akkurt, Serpil

    2015-05-01

    We aimed to evaluate a recently defined technique based on bladder stimulation and paravertebral lumbar massage maneuvers in collecting a midstream clean-catch urine sample in newborns. A total of 127 term newborns were randomly assigned either to the experimental group or the control group. Twenty-five minutes after feeding, the genital and perineal areas of the babies were cleaned. The babies were held under the armpits with legs dangling. Bladder stimulation and lumbar paravertebral massage maneuvers were only applied to the babies in the experimental group. Success was defined as collection of a urine sample within 5 min of starting the stimulation maneuvers in the experimental group and of holding under the armpits in the control group. The success rate of urine collection was significantly higher in the experimental group (78%) than in the control group (33%; p < 0.001). The median time (interquartile range) for sample collection was 60 s (64.5 s) in the experimental group and 300 s (95 s) in the control group (p < 0.0001). Contamination rates were similar in both groups (p = 0.770). We suggest that bladder stimulation and lumbar paravertebral massage is a safe, quick, and effective way of collecting midstream clean-catch urine in newborns.

  8. Optimization and Standardization of Fluorescent Cell Barcoding for Multiplexed Flow Cytometric Phenotyping

    PubMed Central

    Giudice, Valentina; Feng, Xingmin; Kajigaya, Sachiko; Young, Neal S.; Biancotto, Angélique

    2017-01-01

    Fluorescent cell barcoding (FCB) is a cell-based multiplexing technique for high-throughput flow cytometry. Barcoded samples can be stained and acquired collectively, minimizing staining variability and antibody consumption, and decreasing required sample volumes. Combined with functional measurements, FCB can be used for drug screening, signaling profiling, and cytokine detection, but technical issues are present. We optimized the FCB technique for routine utilization using DyLight 350, DyLight 800, Pacific Orange, and CBD500 for barcoding six, nine, or 36 human peripheral blood specimens. Working concentrations of FCB dyes ranging from 0 to 500 μg/ml were tested, and viability dye staining was optimized to increase robustness of data. A five-color staining with surface markers for Vβ usage analysis in CD4+ and CD8+ T cells was achieved in combination with nine sample barcoding. We provide improvements of the FCB technique that should be useful for multiplex drug screening and for lymphocyte characterization and perturbations in the diagnosis and during the course of disease. PMID:28692789

  9. Projection x-ray topography system at 1-BM x-ray optics test beamline at the advanced photon source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stoupin, Stanislav, E-mail: sstoupin@aps.anl.gov; Liu, Zunping; Trakhtenberg, Emil

    2016-07-27

    Projection X-ray topography of single crystals is a classic technique for the evaluation of intrinsic crystal quality of large crystals. In this technique a crystal sample and an area detector (e.g., X-ray film) collecting intensity of a chosen crystallographic reflection are translated simultaneously across an X-ray beam collimated in the diffraction scattering plane (e.g., [1, 2]). A bending magnet beamline of a third-generation synchrotron source delivering x-ray beam with a large horizontal divergence, and therefore, a large horizontal beam size at a crystal sample position offers an opportunity to obtain X-ray topographs of large crystalline samples (e.g., 6-inch wafers) inmore » just a few exposures. Here we report projection X-ray topography system implemented recently at 1-BM beamline of the Advanced Photon Source. A selected X-ray topograph of a 6-inch wafer of 4H-SiC illustrates capabilities and limitations of the technique.« less

  10. Monitoring of occupational exposure to methylene chloride: sampling protocol and stability of urine samples.

    PubMed

    Hoffer, Erica; Tabak, Arek; Shcherb, Inna; Wiener, Avi; Bentur, Yedidia

    2005-01-01

    A sampling protocol for biomonitoring of the volatile solvent methylene chloride (MeCl(2)) by analysis of urine from exposed workers was established. Storage temperature, sample volume in headspace vial (HSV), and time to sealing HSV on determination of MeCl(2) in urine were evaluated. MeCl(2) was analyzed by a solid-phase microextraction technique combined with gas chromatography. Volume of urine in HSV has no effect on MeCl(2) analysis. Delays of 30 and 60 min from collection of urine until sealing the HSV caused 14.47 +/- 6.98% and 26.17 +/- 9.57% decreases from baseline concentration, respectively. MeCl(2) concentration in spiked urine samples stored in sealed HSVs decreased on day 2 and then remained stable for 2 weeks. Refrigeration did not improve recovery although it seems to be associated with less variability. MeCl(2) in urine samples of seven exposed workers was in the range of 0.02-0.06 mg/L. Sampling of MeCl(2)-containing urine should include collection of urine in closed plastic bottles, transfer to HSV within 15 min, sealing and clamping of HSV within 15 s, and storage of HSV in refrigeration until analysis, but no longer than 2 weeks. Standard samples should be prepared on the day of test sample collection and handled under the same conditions.

  11. unmarked: An R package for fitting hierarchical models of wildlife occurrence and abundance

    USGS Publications Warehouse

    Fiske, Ian J.; Chandler, Richard B.

    2011-01-01

    Ecological research uses data collection techniques that are prone to substantial and unique types of measurement error to address scientific questions about species abundance and distribution. These data collection schemes include a number of survey methods in which unmarked individuals are counted, or determined to be present, at spatially- referenced sites. Examples include site occupancy sampling, repeated counts, distance sampling, removal sampling, and double observer sampling. To appropriately analyze these data, hierarchical models have been developed to separately model explanatory variables of both a latent abundance or occurrence process and a conditional detection process. Because these models have a straightforward interpretation paralleling mechanisms under which the data arose, they have recently gained immense popularity. The common hierarchical structure of these models is well-suited for a unified modeling interface. The R package unmarked provides such a unified modeling framework, including tools for data exploration, model fitting, model criticism, post-hoc analysis, and model comparison.

  12. Regression modeling of particle size distributions in urban storm water: advancements through improved sample collection methods

    USGS Publications Warehouse

    Fienen, Michael N.; Selbig, William R.

    2012-01-01

    A new sample collection system was developed to improve the representation of sediment entrained in urban storm water by integrating water quality samples from the entire water column. The depth-integrated sampler arm (DISA) was able to mitigate sediment stratification bias in storm water, thereby improving the characterization of suspended-sediment concentration and particle size distribution at three independent study locations. Use of the DISA decreased variability, which improved statistical regression to predict particle size distribution using surrogate environmental parameters, such as precipitation depth and intensity. The performance of this statistical modeling technique was compared to results using traditional fixed-point sampling methods and was found to perform better. When environmental parameters can be used to predict particle size distributions, environmental managers have more options when characterizing concentrations, loads, and particle size distributions in urban runoff.

  13. Blow Collection as a Non-Invasive Method for Measuring Cortisol in the Beluga (Delphinapterus leucas)

    PubMed Central

    Thompson, Laura A.; Spoon, Tracey R.; Goertz, Caroline E. C.; Hobbs, Roderick C.; Romano, Tracy A.

    2014-01-01

    Non-invasive sampling techniques are increasingly being used to monitor glucocorticoids, such as cortisol, as indicators of stressor load and fitness in zoo and wildlife conservation, research and medicine. For cetaceans, exhaled breath condensate (blow) provides a unique sampling matrix for such purposes. The purpose of this work was to develop an appropriate collection methodology and validate the use of a commercially available EIA for measuring cortisol in blow samples collected from belugas (Delphinapterus leucas). Nitex membrane stretched over a petri dish provided the optimal method for collecting blow. A commercially available cortisol EIA for measuring human cortisol (detection limit 35 pg ml−1) was adapted and validated for beluga cortisol using tests of parallelism, accuracy and recovery. Blow samples were collected from aquarium belugas during monthly health checks and during out of water examination, as well as from wild belugas. Two aquarium belugas showed increased blow cortisol between baseline samples and 30 minutes out of water (Baseline, 0.21 and 0.04 µg dl−1; 30 minutes, 0.95 and 0.14 µg dl−1). Six wild belugas also showed increases in blow cortisol between pre and post 1.5 hour examination (Pre 0.03, 0.23, 0.13, 0.19, 0.13, 0.04 µg dl−1, Post 0.60, 0.31, 0.36, 0.24, 0.14, 0.16 µg dl−1). Though this methodology needs further investigation, this study suggests that blow sampling is a good candidate for non-invasive monitoring of cortisol in belugas. It can be collected from both wild and aquarium animals efficiently for the purposes of health monitoring and research, and may ultimately be useful in obtaining data on wild populations, including endangered species, which are difficult to handle directly. PMID:25464121

  14. Blow collection as a non-invasive method for measuring cortisol in the beluga (Delphinapterus leucas).

    PubMed

    Thompson, Laura A; Spoon, Tracey R; Goertz, Caroline E C; Hobbs, Roderick C; Romano, Tracy A

    2014-01-01

    Non-invasive sampling techniques are increasingly being used to monitor glucocorticoids, such as cortisol, as indicators of stressor load and fitness in zoo and wildlife conservation, research and medicine. For cetaceans, exhaled breath condensate (blow) provides a unique sampling matrix for such purposes. The purpose of this work was to develop an appropriate collection methodology and validate the use of a commercially available EIA for measuring cortisol in blow samples collected from belugas (Delphinapterus leucas). Nitex membrane stretched over a petri dish provided the optimal method for collecting blow. A commercially available cortisol EIA for measuring human cortisol (detection limit 35 pg ml-1) was adapted and validated for beluga cortisol using tests of parallelism, accuracy and recovery. Blow samples were collected from aquarium belugas during monthly health checks and during out of water examination, as well as from wild belugas. Two aquarium belugas showed increased blow cortisol between baseline samples and 30 minutes out of water (Baseline, 0.21 and 0.04 µg dl-1; 30 minutes, 0.95 and 0.14 µg dl-1). Six wild belugas also showed increases in blow cortisol between pre and post 1.5 hour examination (Pre 0.03, 0.23, 0.13, 0.19, 0.13, 0.04 µg dl-1, Post 0.60, 0.31, 0.36, 0.24, 0.14, 0.16 µg dl-1). Though this methodology needs further investigation, this study suggests that blow sampling is a good candidate for non-invasive monitoring of cortisol in belugas. It can be collected from both wild and aquarium animals efficiently for the purposes of health monitoring and research, and may ultimately be useful in obtaining data on wild populations, including endangered species, which are difficult to handle directly.

  15. Monitoring beach changes using GPS surveying techniques

    USGS Publications Warehouse

    Morton, Robert; Leach, Mark P.; Paine, Jeffrey G.; Cardoza, Michael A.

    1993-01-01

    The adaptation of Global Positioning System (GPS) surveying techniques to beach monitoring activities is a promising response to this challenge. An experiment that employed both GPS and conventional beach surveying was conducted, and a new beach monitoring method employing kinematic GPS surveys was devised. This new method involves the collection of precise shore-parallel and shore-normal GPS positions from a moving vehicle so that an accurate two-dimensional beach surface can be generated. Results show that the GPS measurements agree with conventional shore-normal surveys at the 1 cm level, and repeated GPS measurements employing the moving vehicle demonstrate a precision of better than 1 cm. In addition, the nearly continuous sampling and increased resolution provided by the GPS surveying technique reveals alongshore changes in beach morphology that are undetected by conventional shore-normal profiles. The application of GPS surveying techniques combined with the refinement of appropriate methods for data collection and analysis provides a better understanding of beach changes, sediment transport, and storm impacts.

  16. The implementation of liquid-based cytology for lung and pleural-based diseases.

    PubMed

    Michael, Claire W; Bedrossian, Carlos C W M

    2014-01-01

    First introduced for the processing of cervico-vaginal samples, liquid-based cytology (LBC) soon found application in nongynecological specimens, including bronchoscopic brushings, washings and transcutaneous and transbronchial aspiration biopsy of the lung as well as pleural effusions. This article reviews the existing literature related to these specimens along with the authors' own experience. A literature review was conducted through Ovid MEDLINE and PubMed search engines using several key words. Most of the literature is based on data collected through the use of split samples. The data confirms that the use of LBC is an acceptable, and sometimes superior, alternative to the conventional preparations (CP). LBC offers several advantages, including the ability to transport in a stable collecting media, elimination of obscuring elements, ease of screening, excellent preservation, random representative sample, and application of ancillary techniques on additional preparations. Some diagnostic pitfalls related to the introduced artifacts were reported. The utilization of LBC offers many advantages over CP and has a diagnostic accuracy that is equal to or surpasses that of CP. LBC affords a bridge to the future application of molecular and other ancillary techniques to cytology. Knowledge of the morphological artifacts is useful at the early stages of implementation.

  17. Estimating bighorn sheep (Ovis canadensis) abundance using noninvasive sampling at a mineral lick within a National Park Wilderness Area

    USGS Publications Warehouse

    Schoenecker, Kathryn A.; Watry, Mary Kay; Ellison, Laura E.; Schwarz, Michael A.; Luikart, Gordon

    2015-01-01

    Conservation of species requires accurate population estimates. We used genetic markers from feces to determine bighorn sheep abundance for a herd that was hypothesized to be declining and in need of population status monitoring. We sampled from a small but accessible portion of the population's range where animals naturally congregate at a natural mineral lick to test whether we could accurately estimate population size by sampling from an area where animals concentrate. We used mark-recapture analysis to derive population estimates, and compared estimates from this smaller spatial sampling to estimates from sampling of the entire bighorn sheep range. We found that estimates were somewhat comparable; in 2009, the mineral lick sample and entire range sample differed by 20 individuals, and in 2010 they differed by only one individual. However, we captured 13 individuals in the entire range sample that were not captured at the mineral lick, and thus violated a model assumption that all individuals had an equal opportunity of being captured. This eliminated the possibility of inferring a total population estimate from just animals visiting the mineral lick, but because estimates were relatively similar, monitoring at the mineral lick can provide a useful index for management and conservation. We compared our results to a radio-collar study conducted in 2003–2004 and confirmed that the population remained stable since 2004. Our population estimates were 78 (CI 62–114) in 2009 and 95 (CI 77–131) in 2010. Between 7 and 11 sampling dates were needed to achieve a CV of 20% for population estimates, assuming a capture probability between 0.09 and 0.13. We relied on citizen science volunteers to maximize data collection and reduce costs; 71% of all fecal samples were collected by volunteers, compared to 29% collected by paid staff. We conclude that our technique provides a useful monitoring tool for managers. The technique could be tested and applied in similar populations where animals congregate with high fidelity at a mineral lick or other area.

  18. Development of a pre-concentration system and auto-analyzer for dissolved methane, ethane, propane, and butane concentration measurements with a GC-FID

    NASA Astrophysics Data System (ADS)

    Chepigin, A.; Leonte, M.; Colombo, F.; Kessler, J. D.

    2014-12-01

    Dissolved methane, ethane, propane, and butane concentrations in natural waters are traditionally measured using a headspace equilibration technique and gas chromatograph with flame ionization detector (GC-FID). While a relatively simple technique, headspace equilibration suffers from slow equilibration times and loss of sensitivity due to concentration dilution with the pure gas headspace. Here we present a newly developed pre-concentration system and auto-analyzer for use with a GC-FID. This system decreases the time required for each analysis by eliminating the headspace equilibration time, increases the sensitivity and precision with a rapid pre-concentration step, and minimized operator time with an autoanalyzer. In this method, samples are collected from Niskin bottles in newly developed 1 L plastic sample bags rather than glass vials. Immediately following sample collection, the sample bags are placed in an incubator and individually connected to a multiport sampling valve. Water is pumped automatically from the desired sample bag through a small (6.5 mL) Liqui-Cel® membrane contactor where the dissolved gas is vacuum extracted and directly flushed into the GC sample loop. The gases of interest are preferentially extracted with the Liqui-Cel and thus a natural pre-concentration effect is obtained. Daily method calibration is achieved in the field with a five-point calibration curve that is created by analyzing gas standard-spiked water stored in 5 L gas-impermeable bags. Our system has been shown to substantially pre-concentrate the dissolved gases of interest and produce a highly linear response of peak areas to dissolved gas concentration. The system retains the high accuracy, precision, and wide range of measurable concentrations of the headspace equilibration method while simultaneously increasing the sensitivity due to the pre-concentration step. The time and labor involved in the headspace equilibration method is eliminated and replaced with the immediate and automatic analysis of a maximum of 13 sequential samples. The elapsed time between sample collection and analysis is reduced from approximately 12 hrs to < 10 min, enabling dynamic and highly resolved sampling plans.

  19. Non-conventional technologies for data collection in Brazilian dissertations and theses.

    PubMed

    Salvador, Pétala Tuani Candido de Oliveira; Rodrigues, Cláudia Cristiane Filgueira Martins; de Lima, Kálya Yasmine Nunes; Alves, Kisna Yasmin Andrade; Santos, Viviane Euzébia Pereira

    2015-01-01

    to characterize non-conventional technologies used for data collection of dissertations and theses available in the Catalog of Theses and Dissertations (CEPEn) of the Brazilian Nursing Association (ABEn). this is a documentary research, whose data were collected in the catalogs of theses and dissertations available at the ABEn website, from Volumes XIX to XXI. The indicators collected were: academic level; educational institution; year; qualification of the author; setting; non-conventional technology used; type of technology; association with conventional techniques; methodological design; benefits and methodological limitations. from a total of 6346 studies, only 121 (1.91%) used non-conventional technologies for data collection, representing the fi nal sample of the study. it is concluded that Brazilian Nursing researches still need methodological innovations for data collection.

  20. Comparison of Quantifiler(®) Trio and InnoQuant™ human DNA quantification kits for detection of DNA degradation in developed and aged fingerprints.

    PubMed

    Goecker, Zachary C; Swiontek, Stephen E; Lakhtakia, Akhlesh; Roy, Reena

    2016-06-01

    The development techniques employed to visualize fingerprints collected from crime scenes as well as post-development ageing may result in the degradation of the DNA present in low quantities in such evidence samples. Amplification of the DNA samples with short tandem repeat (STR) amplification kits may result in partial DNA profiles. A comparative study of two commercially available quantification kits, Quantifiler(®) Trio and InnoQuant™, was performed on latent fingerprint samples that were either (i) developed using one of three different techniques and then aged in ambient conditions or (ii) undeveloped and then aged in ambient conditions. The three fingerprint development techniques used were: cyanoacrylate fuming, dusting with black powder, and the columnar-thin-film (CTF) technique. In order to determine the differences between the expected quantities and actual quantities of DNA, manually degraded samples generated by controlled exposure of DNA standards to ultraviolet radiation were also analyzed. A total of 144 fingerprint and 42 manually degraded DNA samples were processed in this study. The results indicate that the InnoQuant™ kit is capable of producing higher degradation ratios compared to the Quantifiler(®) Trio kit. This was an expected result since the degradation ratio is a relative value specific for a kit based on the length and extent of amplification of the two amplicons that vary from one kit to the other. Additionally, samples with lower concentrations of DNA yielded non-linear relationships of degradation ratio with the duration of aging, whereas samples with higher concentrations of DNA yielded quasi-linear relationships. None of the three development techniques produced a noticeably different degradation pattern when compared to undeveloped fingerprints, and therefore do not impede downstream DNA analysis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. New Approach for Near-Real-Time Measurement of Elemental Composition of Aerosol Using Laser-Induced Breakdown Spectroscopy

    PubMed Central

    Diwakar, Prasoon; Kulkarni, Pramod; Birch, M. Eileen

    2015-01-01

    A new approach has been developed for making near-real-time measurement of elemental composition of aerosols using plasma spectroscopy. The method allows preconcentration of miniscule particle mass (pg to ng) directly from the sampled aerosol stream through electrostatic deposition of charged particles (30–900 nm) onto a flat-tip microneedle electrode. The collected material is subsequently ablated from the electrode and monitored by laser-induced breakdown spectroscopy. Atomic emission spectra were collected using a broadband spectrometer with a wavelength range of 200–980 nm. A single-sensor delay time of 1.3 μs was used in the spectrometer for all elements to allow simultaneous measurement of multiple elements. The system was calibrated for various elements including Cd, Cr, Cu, Mn, Na, and Ti. The absolute mass detection limits for these elements were experimentally determined and found to be in the range of 0.018–5 ng. The electrostatic collection technique has many advantages over other substrate-based methods involving aerosol collection on a filter or its focused deposition using an aerodynamic lens. Because the particle mass is collected over a very small area that is smaller than the spatial extent of the laser-induced plasma, the entire mass is available for analysis. This considerably improves reliability of the calibration and enhances measurement accuracy and precision. Further, the aerosol collection technique involves very low pressure drop, thereby allowing higher sample flow rates with much smaller pumps—a desirable feature for portable instrumentation. Higher flow rates also make it feasible to measure trace element concentrations at part per trillion levels. Detection limits in the range of 18–670 ng m−3 can be achieved for most of the elements studied at a flow rate of 1.5 L min−1 with sampling times of 5 min. PMID:26692632

  2. Optimization of sampling parameters for collection and preconcentration of alveolar air by needle traps.

    PubMed

    Filipiak, Wojciech; Filipiak, Anna; Ager, Clemens; Wiesenhofer, Helmut; Amann, Anton

    2012-06-01

    The approach for breath-VOCs' collection and preconcentration by applying needle traps was developed and optimized. The alveolar air was collected from only a few exhalations under visual control of expired CO(2) into a large gas-tight glass syringe and then warmed up to 45 °C for a short time to avoid condensation. Subsequently, a specially constructed sampling device equipped with Bronkhorst® electronic flow controllers was used for automated adsorption. This sampling device allows time-saving collection of expired/inspired air in parallel onto three different needle traps as well as improvement of sensitivity and reproducibility of NT-GC-MS analysis by collection of relatively large (up to 150 ml) volume of exhaled breath. It was shown that the collection of alveolar air derived from only a few exhalations into a large syringe followed by automated adsorption on needle traps yields better results than manual sorption by up/down cycles with a 1 ml syringe, mostly due to avoided condensation and electronically controlled stable sample flow rate. The optimal profile and composition of needle traps consists of 2 cm Carbopack X and 1 cm Carboxen 1000, allowing highly efficient VOCs' enrichment, while injection by a fast expansive flow technique requires no modifications in instrumentation and fully automated GC-MS analysis can be performed with a commercially available autosampler. This optimized analytical procedure considerably facilitates the collection and enrichment of alveolar air, and is therefore suitable for application at the bedside of critically ill patients in an intensive care unit. Due to its simplicity it can replace the time-consuming sampling of sufficient breath volume by numerous up/down cycles with a 1 ml syringe.

  3. Spatial variability of soil available phosphorous and potassium at three different soils located in Pannonian Croatia

    NASA Astrophysics Data System (ADS)

    Bogunović, Igor; Pereira, Paulo; Đurđević, Boris

    2017-04-01

    Information on spatial distribution of soil nutrients in agroecosystems is critical for improving productivity and reducing environmental pressures in intensive farmed soils. In this context, spatial prediction of soil properties should be accurate. In this study we analyse 704 data of soil available phosphorus (AP) and potassium (AK); the data derive from soil samples collected across three arable fields in Baranja region (Croatia) in correspondence of different soil types: Cambisols (169 samples), Chernozems (131 samples) and Gleysoils (404 samples). The samples are collected in a regular sampling grid (distance 225 x 225 m). Several geostatistical techniques (Inverse Distance to a Weight (IDW) with the power of 1, 2 and 3; Radial Basis Functions (RBF) - Inverse Multiquadratic (IMT), Multiquadratic (MTQ), Completely Regularized Spline (CRS), Spline with Tension (SPT) and Thin Plate Spline (TPS); and Local Polynomial (LP) with the power of 1 and 2; two geostatistical techniques -Ordinary Kriging - OK and Simple Kriging - SK) were tested in order to evaluate the most accurate spatial variability maps using criteria of lowest RMSE during cross validation technique. Soil parameters varied considerably throughout the studied fields and their coefficient of variations ranged from 31.4% to 37.7% and from 19.3% to 27.1% for soil AP and AK, respectively. The experimental variograms indicate a moderate spatial dependence for AP and strong spatial dependence for all three locations. The best spatial predictor for AP at Chernozem field was Simple kriging (RMSE=61.711), and for AK inverse multiquadratic (RMSE=44.689). The least accurate technique was Thin plate spline (AP) and Inverse distance to a weight with a power of 1 (AK). Radial basis function models (Spline with Tension for AP at Gleysoil and Cambisol and Completely Regularized Spline for AK at Gleysol) were the best predictors, while Thin Plate Spline models were the least accurate in all three cases. The best interpolator for AK at Cambisol was the local polynomial with the power of 2 (RMSE=33.943), while the least accurate was Thin Plate Spline (RMSE=39.572).

  4. Recommendations for level-determined sampling in wells

    NASA Astrophysics Data System (ADS)

    Lerner, David N.; Teutsch, Georg

    1995-10-01

    Level-determined samples of groundwater are increasingly important for hydrogeological studies. The techniques for collecting them range from the use of purpose drilled wells, sometimes with sophisticated dedicated multi-level samplers in them, to a variety of methods used in open wells. Open, often existing, wells are frequently used on cost grounds, but there are risks of obtaining poor and unrepresentative samples. Alternative approaches to level-determined sampling incorporate seven concepts: depth sampling; packer systems; individual wells; dedicated multi-level systems; separation pumping; baffle systems; multi-port sock samplers. These are outlined and evaluated in terms of the environment to be sampled, and the features and performance of the methods. Recommendations are offered to match methods to sampling problems.

  5. Preservice Teachers' Preferences about Instructor Gender

    ERIC Educational Resources Information Center

    Yapici, Senay

    2014-01-01

    This is a qualitative research. Interview technique was used to collect data and the data were analyzed using quantifying the qualitative data. The participants were selected using convenience sampling method. They comprised 99 (51 female, 48 male) preservice teachers studying at eleven education faculties around Turkey. The consistency percentage…

  6. Microflora in soils of desert regions

    NASA Technical Reports Server (NTRS)

    Cameron, R. E.

    1970-01-01

    Desert soil samples, collected using aseptic techniques, are low in organic matter and cation exchange capacity. Aerobic and microaerophilic bacteria are most abundant, next are algae and molds. Chemical and physical properties are determined by standard procedures, including the Kjeldahl method and the use of Munsell soil color charts.

  7. Water Quality & Pollutant Source Monitoring: Field and Laboratory Procedures. Training Manual.

    ERIC Educational Resources Information Center

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This training manual presents material on techniques and instrumentation used to develop data in field monitoring programs and related laboratory operations concerned with water quality and pollution monitoring. Topics include: collection and handling of samples; bacteriological, biological, and chemical field and laboratory methods; field…

  8. Spatial Description of Drinking Water Bacterial Community Structures in Bulk Water Samples Collected in a Metropolitan Distribution System

    EPA Science Inventory

    The description of microorganisms inhabiting drinking water distribution systems has commonly been performed using techniques that are biased towards easy to culture bacterial populations. As most environmental microorganisms cannot be grown on artificial media, our understanding...

  9. Nuclear Ensemble Approach with Importance Sampling.

    PubMed

    Kossoski, Fábris; Barbatti, Mario

    2018-06-12

    We show that the importance sampling technique can effectively augment the range of problems where the nuclear ensemble approach can be applied. A sampling probability distribution function initially determines the collection of initial conditions for which calculations are performed, as usual. Then, results for a distinct target distribution are computed by introducing compensating importance sampling weights for each sampled point. This mapping between the two probability distributions can be performed whenever they are both explicitly constructed. Perhaps most notably, this procedure allows for the computation of temperature dependent observables. As a test case, we investigated the UV absorption spectra of phenol, which has been shown to have a marked temperature dependence. Application of the proposed technique to a range that covers 500 K provides results that converge to those obtained with conventional sampling. We further show that an overall improved rate of convergence is obtained when sampling is performed at intermediate temperatures. The comparison between calculated and the available measured cross sections is very satisfactory, as the main features of the spectra are correctly reproduced. As a second test case, one of Tully's classical models was revisited, and we show that the computation of dynamical observables also profits from the importance sampling technique. In summary, the strategy developed here can be employed to assess the role of temperature for any property calculated within the nuclear ensemble method, with the same computational cost as doing so for a single temperature.

  10. Simultaneous determination of thirteen organophosphate esters in settled indoor house dust and a comparison between two sampling techniques.

    PubMed

    Fan, Xinghua; Kubwabo, Cariton; Rasmussen, Pat E; Wu, Fang

    2014-09-01

    An analytical method for the simultaneous determination of 13 organophosphate esters (OPEs) in house dust was developed. The method is based on solvent extraction by sonication, sample cleanup by solid phase extraction (SPE), and analysis by gas chromatography-positive chemical ionization-tandem mass spectrometry (GC/PCI-MS/MS). Method detection limits (MDLs) ranged from 0.03 to 0.43 μg/g and recoveries from 60% to 118%. The inter- and intra-day variations ranged from 3% to 23%. The method was applied to dust samples collected using two vacuum sampling techniques from 134 urban Canadian homes: a sample of fresh or "active" dust (FD) collected by technicians and a composite sample taken from the household vacuum cleaner (HD). Results show that the two sampling methods (i.e., FD vs HD) provided comparable results. Tributoxyethyl phosphate (TBEP), triphenyl phosphate (TPhP), tris(chloropropyl) phosphate (TCPP), tri(2-chloroethyl) phosphate (TCEP), tris(dichloro-isopropyl) phosphate (TDCPP), tricresyl phosphate (TCrP), and tri-n-butyl phosphate (TnBP) were detected in the majority of samples. The most predominant OPE was TBEP, with median concentrations of 31.9 μg/g and 22.8 μg/g in FD and HD samples, respectively, 1 to 2 orders of magnitude higher than other OPEs. The method was also applied to the analysis of OPEs in the National Institute of Standards and Technology (NIST) standard reference material (NIST SRM 2585, organic contaminants in house dust). The results from SRM 2585 may contribute to the certification of OPE concentration values in this SRM. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  11. Evaluation of the contribution of smoking to total blood polonium-210 in Saudi population.

    PubMed

    Shabana, E I; Abd Elaziz, M A; Al-Arifi, M N; Al-Dhawailie, A A; Al-Bokari, M M

    2000-01-01

    A preliminary study of 210Po concentrations in the blood of some smokers and nonsmokers is presented in order to evaluate the contribution of smoking to total blood 210Po in Saudi population. Blood samples were collected from 30 volunteers and analyzed by high resolution alpha-spectrometry using a radiochemical technique. The technique is based on the separation of polonium from other components of the sample by wet ashing with an HNO3/H2O2 oxidizing mixture and spontaneous deposition on a silver disc under the relevant conditions for alpha-particle counting. The results indicated that a significant fraction (about 30%) of blood 210Po is related to smoking.

  12. Cytological techniques to study human female meiotic prophase.

    PubMed

    Roig, Ignasi; Garcia-Caldés, Montserrat

    2009-01-01

    Most of the human aneuploidies have a maternal origin. This feature makes the study of human female meiosis a fundamental topic to understand the reasons leading to this important social problem. Unfortunately, due to sample collection difficulties, not many studies have been performed on human female meiotic prophase. In this chapter we present a comprehensive collection of protocols that allows the study of human female meiotic prophase through different technical approaches using both spread and structurally preserved oocytes.

  13. A novel visually CO2 controlled alveolar breath sampling technique.

    PubMed

    Birken, Thomas; Schubert, Jochen; Miekisch, Wolfram; Nöldge-Schomburg, Gabriele

    2006-01-01

    A crucial issue in the analysis of exhaled breath is the collection of gaseous samples. The analysis of pure alveolar gas is the method of choice if contamination of samples is to be minimized. Monitoring of expired CO2 can be used to identify alveolar gas. The purpose of this study was to evaluate a bed side version of this technique using visual CO2 control by means of a capnometer. 22 mechanically ventilated patients of an ICU were enrolled into the study. Alveolar and mixed expiratory gas, and arterial blood were sampled. PCO2 in blood and gas was determined in a blood gas analyzer. End tidal PCO2 was monitored in all patients by a fast responding main stream capnometry. Taking the gaseous samples was visually synchronized with the expired CO2. Alveolar CO2 contents measured during two different respiratory cycles were identical (p 0.86). The variation of the CO2 content during 10 measurements in one patient was lower than 4%. Arterial PCO2, PCO2 in alveolar gas and end tidal PCO2 showed positive correlation. The visually CO2-controlled sampling technique of alveolar gas is a reliable and reproducible method. It represents an important step in simplifying and standardizing breath analysis.

  14. SOIL AND SEDIMENT SAMPLING METHODS | Science ...

    EPA Pesticide Factsheets

    The EPA Office of Solid Waste and Emergency Response's (OSWER) Office of Superfund Remediation and Technology Innovation (OSRTI) needs innovative methods and techniques to solve new and difficult sampling and analytical problems found at the numerous Superfund sites throughout the United States. Inadequate site characterization and a lack of knowledge of surface and subsurface contaminant distributions hinders EPA's ability to make the best decisions on remediation options and to conduct the most effective cleanup efforts. To assist OSWER, NERL conducts research to improve their capability to more accurately, precisely, and efficiently characterize Superfund, RCRA, LUST, oil spills, and brownfield sites and to improve their risk-based decision making capabilities, research is being conducted on improving soil and sediment sampling techniques and improving the sampling and handling of volatile organic compound (VOC) contaminated soils, among the many research programs and tasks being performed at ESD-LV.Under this task, improved sampling approaches and devices will be developed for characterizing the concentration of VOCs in soils. Current approaches and devices used today can lose up to 99% of the VOCs present in the sample due inherent weaknesses in the device and improper/inadequate collection techniques. This error generally causes decision makers to markedly underestimate the soil VOC concentrations and, therefore, to greatly underestimate the ecological

  15. Development of a transcutaneous blood-constituent monitoring method using a suction effusion fluid collection technique and an ion-sensitive field-effect transistor glucose sensor.

    PubMed

    Ito, N; Kayashima, S; Kimura, J; Kuriyama, T; Arai, T; Kikuchi, M; Nagata, N

    1994-05-01

    The paper describes a method for the transcutaneous monitoring of blood constituents. It combines the use of a suction effusion fluid (SEF) collecting technique with a silicon on sapphire/ion-sensitive field-effect transistor (SOS/ISFET) biosensor. SEF is directly collected by a weak evacuation through skin from which the stratum corneum has been removed. An SEF collecting cell with a stainless-steel mesh at the bottom is kept in a weak vacuum condition, and SEF is sucked up through the mesh and deposited in a reservoir above. An ISFET glucose sensor is able to detect glucose concentrations in very small SEF samples through the use of two small ISFETs and an immobilised enzyme membrane. The reliability of transcutaneously obtained SEF was first confirmed in an experiment using rabbits. A clinical analyser was used to determine levels of glucose, urea nitrogen and creatinine in SEF obtained transcutaneously; these results are compared with results obtained by the same analyser directly from sera. The ISFET glucose sensor was successfully tested on human subjects for the monitoring of blood glucose levels. During these tests, glucose level changes in the SEF followed actual blood glucose level changes with a slight time delay. Results suggest the feasibility of non-invasive, transcutaneous monitoring of low molecular weight substances in the blood without the use of ordinary blood sampling.

  16. SIMPLE MEASURES ARE AS EFFECTIVE AS INVASIVE TECHNIQUES IN THE DIAGNOSIS OF PULMONARY TUBERCULOSIS IN MALAWI

    PubMed Central

    Bell, David J; Dacombe, Russell; Graham, Stephen M; Hicks, Alexander; Cohen, Danielle; Chikaonda, Tarsizio; French, Neil; Molyneux, Malcolm E; Zijlstra, Ed E; Squire, S Bertel; Gordon, Stephen B

    2010-01-01

    Setting Detection of smear-positive pulmonary tuberculosis (PTB) cases is vital for tuberculosis control. Methods to augment sputum collection are available but their additional benefit is uncertain in resource-limited settings. Objective To compare the diagnostic yields using five methods to obtain sputum from adults diagnosed with smear-negative PTB in Malawi. Design Self-expectorated sputum was collected under supervision for microscopy and mycobacterial culture in the study laboratory. Confirmed smear-negative patients, provided physiotherapy-assisted sputum and induced sputum followed, the next morning, by gastric washing and bronchoalveolar-lavage samples. Results 150 patients, diagnosed with smear-negative PTB by the hospital service, were screened. 39 (26%) were smear-positive from supervised self-expectorated sputum examined in the study laboratory. The remaining 111 confirmed smear-negative patients were enrolled; 89% were HIV positive. Seven additional smear-positive cases were diagnosed using the augmented sputum collection techniques. No differences were observed in the numbers of cases detected using the different methods. 44 (95.6%) of the 46 smear-positive cases could be detected from self-expectorated and physiotherapy-assisted samples Conclusions For countries like Malawi, the best use of limited resources to detect smear-positive PTB cases would be to improve the quality of self-expectorated sputum collection and microscopy. The additional diagnostic yield using bronchoalveolar-lavage after induced sputum is limited. PMID:19105886

  17. Influence of Post-Mortem Sperm Recovery Method and Extender on Unstored and Refrigerated Rooster Sperm Variables.

    PubMed

    Villaverde-Morcillo, S; Esteso, M C; Castaño, C; Santiago-Moreno, J

    2016-02-01

    Many post-mortem sperm collection techniques have been described for mammalian species, but their use in birds is scarce. This paper compares the efficacy of two post-mortem sperm retrieval techniques - the flushing and float-out methods - in the collection of rooster sperm, in conjunction with the use of two extenders, i.e., L&R-84 medium and Lake 7.1 medium. To determine whether the protective effects of these extenders against refrigeration are different for post-mortem and ejaculated sperm, pooled ejaculated samples (procured via the massage technique) were also diluted in the above extenders. Post-mortem and ejaculated sperm variables were assessed immediately at room temperature (0 h), and after refrigeration at 5°C for 24 and 48 h. The flushing method retrieved more sperm than the float-out method (596.5 ± 75.4 million sperm vs 341.0 ± 87.6 million sperm; p < 0.05); indeed, the number retrieved by the former method was similar to that obtained by massage-induced ejaculation (630.3 ± 78.2 million sperm). For sperm collected by all methods, the L&R-84 medium provided an advantage in terms of sperm motility variables at 0 h. In the refrigerated sperm samples, however, the Lake 7.1 medium was associated with higher percentages of viable sperm, and had a greater protective effect (p < 0.05) with respect to most motility variables. In conclusion, the flushing method is recommended for collecting sperm from dead birds. If this sperm needs to be refrigerated at 5°C until analysis, Lake 7.1 medium is recommended as an extender. © 2015 Blackwell Verlag GmbH.

  18. Water-management models in Florida from ERTS-1 data

    NASA Technical Reports Server (NTRS)

    Higer, A. L. (Principal Investigator); Rogers, R. H.; Coker, A. E.; Cordes, E. H.

    1975-01-01

    The author has identified the following significant results. The usefullness of ERTS 1 to improving the overall effectiveness of collecting and disseminating data was evaluated. ERTS MSS imagery and in situ monitoring by DCS were used to evaluate their separate and combined capabilities. Twenty data collection platforms were established in southern Florida. Water level and rainfall measurements were collected and disseminated to users in less than 2 hours, a significant improvement over conventional techniques requiring 2 months. ERTS imagery was found to significantly enhance the utility of ground measurements. Water stage was correlated with water surface areas from imagery in order to obtain water stage-volume relations. Imagery provided an economical basis for extrapolating water parameters from the point samples to unsampled data and provided a synoptic view of water mass boundaries that no amount of ground sampling or monitoring could provide.

  19. Detection of and monitoring for Aedes albopictus (Diptera: Culicidae) in suburban and sylvatic habitats in north central Florida using four sampling techniques.

    PubMed

    Obenauer, P J; Kaufman, P E; Kline, D L; Allan, S A

    2010-10-01

    A sampling study using a BG-Sentinel trap baited with CO(2), a gravid trap baited with an oak-pine infusion, a human subject, and a vegetative aspirator was conducted to compare their reliability at detecting Aedes albopictus Skuse in suburban and sylvatic habitats. We collected 73,849 mosquitoes, representing 29 species from 11 genera over a 20-wk period. The BG-Sentinel trap accounted for over 85% of all Ae. albopictus captured and was significantly more effective at detecting the presence of Ae. albopictus compared with the other three techniques. Landing counts provided the fewest mosquito species (n = 10), yet provided a quick and effective weekly assessment of the major biting species and were the most effective method for sampling Ae. albopictus within a 10-min period. Fewer Ae. albopictus were sampled from sylvatic habitats compared with suburban ones. Sampling criteria advantageous for surveying Ae. albopictus and other mosquito species are discussed.

  20. Sampling of atmospheric carbonyl compounds for determination by liquid chromatography after 2,4-dinitrophenylhydrazine labelling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vairavamurthy, A.; Roberts, J.M.; Newman, L.

    1991-06-01

    Carbonyl compounds are both primary (directly emitted) and secondary (formed in situ) atmospheric species, which play a major role in tropospheric photochemistry. Because of trace concentrations (parts-per-billion and lower), ambient air measurements of carbonyls pose serious analytical problems. Generally, chromatographic approaches combined with chemical derivatization have been used to enhance sensitivity and selectivity in analysis. Currently, the liquid chromatographic method coupled to 2,4-dinitrophenylhydrazine derivatization (DNPH-LC) is in widespread use. Interferences arising from similar compounds are greatly minimized by chromatographic separation; however, those in the air sampling step, especially with ozone, continue to be problematic and remain to be resolved. Wemore » discuss here the different sampling techniques used for time-integrated collection of carbonyls in the DNPH-LC methods. Emphasis is placed on addressing: (1) the principles, advantages, and limitations of sampling techniques; (2) problems associated with reagent blank and sampling instrument; and (3) effects of atmospheric co-pollutants, especially ozone. 58 refs., 8 figs., 3 tabs.« less

  1. In-situ X-ray diffraction system using sources and detectors at fixed angular positions

    DOEpatents

    Gibson, David M [Voorheesville, NY; Gibson, Walter M [Voorheesville, NY; Huang, Huapeng [Latham, NY

    2007-06-26

    An x-ray diffraction technique for measuring a known characteristic of a sample of a material in an in-situ state. The technique includes using an x-ray source for emitting substantially divergent x-ray radiation--with a collimating optic disposed with respect to the fixed source for producing a substantially parallel beam of x-ray radiation by receiving and redirecting the divergent paths of the divergent x-ray radiation. A first x-ray detector collects radiation diffracted from the sample; wherein the source and detector are fixed, during operation thereof, in position relative to each other and in at least one dimension relative to the sample according to a-priori knowledge about the known characteristic of the sample. A second x-ray detector may be fixed relative to the first x-ray detector according to the a-priori knowledge about the known characteristic of the sample, especially in a phase monitoring embodiment of the present invention.

  2. A rapid isothermal assay for the detection of Hop stunt viroid in hop plants (Humulus lupulus), and its application in disease surveys.

    PubMed

    Kappagantu, Madhu; Villamor, Dan Edward V; Bullock, Jeff M; Eastwell, Kenneth C

    2017-07-01

    Hop stunt disease caused by Hop stunt viroid (HSVd) is a growing threat to hop cultivation globally. HSVd spreads mainly by use of contaminated planting material and by mechanical means. Thorough testing of hop yards and removal of infected bines are critical components of efforts to control the spread of the disease. Reverse transcription-polymerase chain reaction (RT-PCR) has become the primary technique used for HSVd detection; however, sample handling and analysis are technically challenging. In this study, a robust reverse transcription-recombinase polymerase amplification (RT-RPA) assay was developed to facilitate analysis of multiple samples. The assay was optimized with all major variants of HSVd from other host species in addition to hop variants. Used in conjunction with sample collection cards, RT-RPA accommodates large sample numbers. Greenhouse and farm samples tested with RT-RPA were also tested with RT-PCR and a 100% correlation between the two techniques was found. Copyright © 2017. Published by Elsevier B.V.

  3. Analysis of "Midnight" Tracks in the Stardust Interstellar Dust Collector: Possible Discovery of a Contemporary Interstellar Dust Grain

    NASA Technical Reports Server (NTRS)

    Westphal, A. J.; Allen, C.; Bajit, S.; Bastien, R.; Bechtel, H.; Bleuet, P.; Borg, J.; Brenker, F.; Bridges, J.; Brownlee, D. E.; hide

    2010-01-01

    In January 2006, the Stardust sample return capsule returned to Earth bearing the first solid samples from a primitive solar system body, Comet 81P/Wild2, and a collector dedicated to the capture and return of contemporary interstellar dust. Both collectors were approximately 0.1m(exp 2) in area and were composed of aerogel tiles (85% of the collecting area) and aluminum foils. The Stardust Interstellar Dust Collector (SIDC) was exposed to the interstellar dust stream for a total exposure factor of 20 m(exp 2) day. The Stardust Interstellar Preliminary Examination (ISPE) is a three-year effort to characterize the collection using nondestructive techniques.

  4. Physical Validation of TRMM TMI and PR Monthly Rain Products Over Oklahoma

    NASA Technical Reports Server (NTRS)

    Fisher, Brad L.

    2004-01-01

    The Tropical Rainfall Measuring Mission (TRMM) provides monthly rainfall estimates using data collected by the TRMM satellite. These estimates cover a substantial fraction of the earth's surface. The physical validation of TRMM estimates involves corroborating the accuracy of spaceborne estimates of areal rainfall by inferring errors and biases from ground-based rain estimates. The TRMM error budget consists of two major sources of error: retrieval and sampling. Sampling errors are intrinsic to the process of estimating monthly rainfall and occur because the satellite extrapolates monthly rainfall from a small subset of measurements collected only during satellite overpasses. Retrieval errors, on the other hand, are related to the process of collecting measurements while the satellite is overhead. One of the big challenges confronting the TRMM validation effort is how to best estimate these two main components of the TRMM error budget, which are not easily decoupled. This four-year study computed bulk sampling and retrieval errors for the TRMM microwave imager (TMI) and the precipitation radar (PR) by applying a technique that sub-samples gauge data at TRMM overpass times. Gridded monthly rain estimates are then computed from the monthly bulk statistics of the collected samples, providing a sensor-dependent gauge rain estimate that is assumed to include a TRMM equivalent sampling error. The sub-sampled gauge rain estimates are then used in conjunction with the monthly satellite and gauge (without sub- sampling) estimates to decouple retrieval and sampling errors. The computed mean sampling errors for the TMI and PR were 5.9% and 7.796, respectively, in good agreement with theoretical predictions. The PR year-to-year retrieval biases exceeded corresponding TMI biases, but it was found that these differences were partially due to negative TMI biases during cold months and positive TMI biases during warm months.

  5. Technical note: An improved approach to determining background aerosol concentrations with PILS sampling on aircraft

    NASA Astrophysics Data System (ADS)

    Fukami, Christine S.; Sullivan, Amy P.; Ryan Fulgham, S.; Murschell, Trey; Borch, Thomas; Smith, James N.; Farmer, Delphine K.

    2016-07-01

    Particle-into-Liquid Samplers (PILS) have become a standard aerosol collection technique, and are widely used in both ground and aircraft measurements in conjunction with off-line ion chromatography (IC) measurements. Accurate and precise background samples are essential to account for gas-phase components not efficiently removed and any interference in the instrument lines, collection vials or off-line analysis procedures. For aircraft sampling with PILS, backgrounds are typically taken with in-line filters to remove particles prior to sample collection once or twice per flight with more numerous backgrounds taken on the ground. Here, we use data collected during the Front Range Air Pollution and Photochemistry Éxperiment (FRAPPÉ) to demonstrate that not only are multiple background filter samples are essential to attain a representative background, but that the chemical background signals do not follow the Gaussian statistics typically assumed. Instead, the background signals for all chemical components analyzed from 137 background samples (taken from ∼78 total sampling hours over 18 flights) follow a log-normal distribution, meaning that the typical approaches of averaging background samples and/or assuming a Gaussian distribution cause an over-estimation of background samples - and thus an underestimation of sample concentrations. Our approach of deriving backgrounds from the peak of the log-normal distribution results in detection limits of 0.25, 0.32, 3.9, 0.17, 0.75 and 0.57 μg m-3 for sub-micron aerosol nitrate (NO3-), nitrite (NO2-), ammonium (NH4+), sulfate (SO42-), potassium (K+) and calcium (Ca2+), respectively. The difference in backgrounds calculated from assuming a Gaussian distribution versus a log-normal distribution were most extreme for NH4+, resulting in a background that was 1.58× that determined from fitting a log-normal distribution.

  6. Drinking water quality assessment.

    PubMed

    Aryal, J; Gautam, B; Sapkota, N

    2012-09-01

    Drinking water quality is the great public health concern because it is a major risk factor for high incidence of diarrheal diseases in Nepal. In the recent years, the prevalence rate of diarrhoea has been found the highest in Myagdi district. This study was carried out to assess the quality of drinking water from different natural sources, reservoirs and collection taps at Arthunge VDC of Myagdi district. A cross-sectional study was carried out using random sampling method in Arthunge VDC of Myagdi district from January to June,2010. 84 water samples representing natural sources, reservoirs and collection taps from the study area were collected. The physico-chemical and microbiological analysis was performed following standards technique set by APHA 1998 and statistical analysis was carried out using SPSS 11.5. The result was also compared with national and WHO guidelines. Out of 84 water samples (from natural source, reservoirs and tap water) analyzed, drinking water quality parameters (except arsenic and total coliform) of all water samples was found to be within the WHO standards and national standards.15.48% of water samples showed pH (13) higher than the WHO permissible guideline values. Similarly, 85.71% of water samples showed higher Arsenic value (72) than WHO value. Further, the statistical analysis showed no significant difference (P<0.05) of physico-chemical parameters and total coliform count of drinking water for collection taps water samples of winter (January, 2010) and summer (June, 2010). The microbiological examination of water samples revealed the presence of total coliform in 86.90% of water samples. The results obtained from physico-chemical analysis of water samples were within national standard and WHO standards except arsenic. The study also found the coliform contamination to be the key problem with drinking water.

  7. Diagnostic value of JC/BK virus antibody immunohistochemistry staining in urine samples from posttransplant immunosuppressed patients in relation to polyomavirus reactivation.

    PubMed

    Yuste, Rosario Sanchez; Frías, Carolina; López, Ana; Vallejo, Carlos; Martín, Paloma; Bellas, Carmen

    2008-01-01

    To compare the diagnostic value of cytology and immunohistochemistry staining (IHS) of urine samples for polyomavirus reactivation diagnosis. Sixty-eight urine samples collected from 18 immunosuppressed patients were analyzed by Papanicolaou and IHS with a JC/BK virus-specific monoclonal antibody. Overall, polyomavirus BK (BKV) was positive in 11 of 18 patients (61.1%) (3 of whom developed hemorrhagic cystitis) and in 23 of 68 urine samples (28%). Of 23 samples, 4 (17%) were positive by 1 of the 2 techniques, only. Of 23 samples, 19 (83%) were positive by both methods. In matching urine samples from the same patient, the number of BKV-infected positive cells detected by IHS in urine slides was higher than those detected by Papanicolaou staining (71.3%). The main advantage of LHS is that it allowed confirmation of BKV infection diagnosis in urine samples. IHS detected more BKV-infected cells in samples with few positive urothelial cells, which would have gone undetected if only Papanicolaou staining had been used as the BKV screening method. Urine samples testing for BKV by both techniques will improve diagnosis in asymptomatic patients, allowing early therapeutic intervention and a better clinical outcome.

  8. Instrumental neutron activation analysis for studying size-fractionated aerosols

    NASA Astrophysics Data System (ADS)

    Salma, Imre; Zemplén-Papp, Éva

    1999-10-01

    Instrumental neutron activation analysis (INAA) was utilized for studying aerosol samples collected into a coarse and a fine size fraction on Nuclepore polycarbonate membrane filters. As a result of the panoramic INAA, 49 elements were determined in an amount of about 200-400 μg of particulate matter by two irradiations and four γ-spectrometric measurements. The analytical calculations were performed by the absolute ( k0) standardization method. The calibration procedures, application protocol and the data evaluation process are described and discussed. They make it possible now to analyse a considerable number of samples, with assuring the quality of the results. As a means of demonstrating the system's analytical capabilities, the concentration ranges, median or mean atmospheric concentrations and detection limits are presented for an extensive series of aerosol samples collected within the framework of an urban air pollution study in Budapest. For most elements, the precision of the analysis was found to be beyond the uncertainty represented by the sampling techniques and sample variability.

  9. Occurrence of pharmaceuticals and other organic wastewater constituents in selected streams in northern Arkansas, 2004

    USGS Publications Warehouse

    Galloway, Joel M.; Haggard, Brian E.; Meyers, Michael T.; Green, W. Reed

    2005-01-01

    The U.S. Geological Survey, in cooperation with the University of Arkansas and the U.S. Department of Agriculture, Agricultural Research Service, collected data in 2004 to determine the occurrence of pharmaceuticals and other organic wastewater constituents, including many constituents of emerging environmental concern, in selected streams in northern Arkansas. Samples were collected in March and April 2004 from 17 sites located upstream and downstream from wastewater- treatment plant effluent discharges on 7 streams in northwestern Arkansas and at 1 stream site in a relatively undeveloped basin in north-central Arkansas. Additional samples were collected at three of the sites in August 2004. The targeted organic wastewater constituents and sample sites were selected because wastewater-treatment plant effluent discharge provides a potential point source of these constituents and analytical techniques have improved to accurately measure small amounts of these constituents in environmental samples. At least 1 of the 108 pharmaceutical or other organic wastewater constituents was detected at all sites in 2004, except at Spavinaw Creek near Maysville, Arkansas. The number of detections generally was greater at sites downstream from municipal wastewater-treatment plant effluent discharges (mean = 14) compared to sites not influenced by wastewatertreatment plants (mean = 3). Overall, 42 of the 108 constituents targeted in the collected water-quality samples were detected. The most frequently detected constituents included caffeine, phenol, para-cresol, and acetyl hexamethyl tetrahydro naphthalene.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, Audrey Noreen

    Homeland security relies heavily on analytical chemistry to identify suspicious materials and persons. Traditionally this role has focused on attribution, determining the type and origin of an explosive, for example. But as technology advances, analytical chemistry can and will play an important role in the prevention and preemption of terrorist attacks. More sensitive and selective detection techniques can allow suspicious materials and persons to be identified even before a final destructive product is made. The work presented herein focuses on the use of commercial and novel detection techniques for application to the prevention of terrorist activities. Although drugs are notmore » commonly thought of when discussing terrorism, narcoterrorism has become a significant threat in the 21st century. The role of the drug trade in the funding of terrorist groups is prevalent; thus, reducing the trafficking of illegal drugs can play a role in the prevention of terrorism by cutting off much needed funding. To do so, sensitive, specific, and robust analytical equipment is needed to quickly identify a suspected drug sample no matter what matrix it is in. Single Particle Aerosol Mass Spectrometry (SPAMS) is a novel technique that has previously been applied to biological and chemical detection. The current work applies SPAMS to drug analysis, identifying the active ingredients in single component, multi-component, and multi-tablet drug samples in a relatively non-destructive manner. In order to do so, a sampling apparatus was created to allow particle generation from drug tablets with on-line introduction to the SPAMS instrument. Rules trees were developed to automate the identification of drug samples on a single particle basis. A novel analytical scheme was also developed to identify suspect individuals based on chemical signatures in human breath. Human breath was sampled using an RTube{trademark} and the trace volatile organic compounds (VOCs) were preconcentrated using solid phase microextraction (SPME) and identified using gas chromatography - mass spectrometry (GC-MS). Modifications to the sampling apparatus allowed for increased VOC collection efficiency, and reduced the time of sampling and analysis by over 25%. The VOCs are present in breath due to either endogenous production, or exposure to an external source through absorption, inhalation, or ingestion. Detection of these exogenous chemicals can provide information on the prior location and activities of the subject. Breath samples collected before and after exposure in a hardware store and nail salon were analyzed to investigate the prior location of a subject; breath samples collected before and after oral exposure to terpenes and terpenoid compounds, pseudoephedrine, and inhalation exposure to hexamine and other explosive related compounds were analyzed to investigate the prior activity of a subject. The elimination of such compounds from the body was also monitored. In application, this technique may provide an early warning system to identify persons of interest in the prevention and preemption stages of homeland security.« less

  11. NASA/BLM APT, phase 2. Volume 2: Technology demonstration. [Arizona

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Techniques described include: (1) steps in the preprocessing of LANDSAT data; (2) the training of a classifier; (3) maximum likelihood classification and precision; (4) geometric correction; (5) class description; (6) digitizing; (7) digital terrain data; (8) an overview of sample design; (9) allocation and selection of primary sample units; (10) interpretation of secondary sample units; (11) data collection ground plots; (12) data reductions; (13) analysis for productivity estimation and map verification; (14) cost analysis; and (150) LANDSAT digital products. The evaluation of the pre-inventory planning for P.J. is included.

  12. Comparison of five parasitological techniques for laboratory diagnosis of Balantidium coli cysts.

    PubMed

    Barbosa, Alynne da Silva; Bastos, Otilio Machado Pereira; Uchôa, Claudia Maria Antunes; Pissinatti, Alcides; Bastos, Augusto César Machado Pereira; Souza, Igo Vieira de; Dib, Laís Verdan; Azevedo, Eduarda Peixoto; Siqueira, Mayara Perlingeiro de; Cardozo, Matheus Lessa; Amendoeira, Maria Regina Reis

    2016-01-01

    Balantidium coli is a protozoon that can cause dysentery in humans, pigs and nonhuman primates, with zoonotic potential. In the literature, there is still little information on the effectiveness of different laboratory techniques for diagnosing this disease. This study compared and evaluated the performance of the Lutz, modified Ritchie, Faust, modified Sheather and direct examination techniques for detecting cysts of this protozoon. Between 2012 and 2014, 1905 fecal samples were collected from captive animals in the state of Rio de Janeiro. Of these, 790 were obtained from the rectum of pigs and 1115 from enclosures occupied by nonhuman primates. B. coli cysts were most evident through direct examination (22.4% of the samples) and the Lutz technique (21%). Fair agreement (Kappa = 0.41; p < 0.05) was observed only between direct examination and Lutz. The flotation techniques (Faust and modified Sheather) did not show good recovery of cysts. A statistically significant difference (p < 0.05) in the frequency of cysts between pigs and nonhuman primates could only be observed through direct examination and the Lutz technique. The most efficient method for diagnosing this parasitosis was seen to an association between direct examination and the spontaneous sedimentation technique.

  13. Low faunal diversity on Maltese sandy beaches: fact or artefact?

    NASA Astrophysics Data System (ADS)

    Deidun, Alan; Azzopardi, Marthese; Saliba, Stephen; Schembri, Patrick J.

    2003-10-01

    Eight sandy beaches on Malta and two on Gozo were sampled for macrofauna to test the hypothesis that Maltese beaches have an intrinsically low diversity. Stations distributed in the supralittoral (dry zone), mediolittoral (wet zone) and upper infralittoral (submerged zone to 1 m water depth) were sampled by sieving core samples and standardised searching during daytime, and pitfall trapping and standardised sweeping of the water column using a hand-net at night, as appropriate. Physical parameters of the sediment were measured and human occupancy of the beaches was estimated. From the supralittoral and mediolittoral, 39 species represented by 1584 individuals were collected by the combined techniques of pitfall trapping, sieving and standard searching. For Ramla beach, which had the highest diversity, 267 individuals representing 25 infaunal species were collected by sieving from a combined volume of 1.175 m 3 of sand, and 149 individuals representing 28 epifaunal species were collected by standardised searching from a combined area of 700 m 2 of sand during two winter and two summer sampling sessions between 1992 and 1993. For nine other beaches sampled during the summer of 2000, only six macrofaunal species were collected from core samples, with overall population densities ranging from 4.13 to 45.45 individuals m -2. Only 92 individuals belonging to 12 species were collected by hand-net from the uppermost infralittoral of five beaches sampled using this method during the summer of 2000. Taxa of gastropods, bivalves, decapods, mysids and staphylinid beetles generally abundant on Mediterranean sandy beaches, were entirely absent from the beaches sampled. Few correlations that could explain the impoverishment of Maltese sandy beaches were found between physical parameters and faunal abundances, and other factors such as inadequate sampling effort, human disturbance and marine pollution were also excluded; however, seasonally biased sampling may partly explain the results obtained. One factor that may explain why certain species are missing could be lack of recruitment, due to Malta's geographical isolation from the European and African mainlands.

  14. The Growth of Human Hair.

    ERIC Educational Resources Information Center

    Jones, Helen J.

    1984-01-01

    Suggests a simple technique for collecting and observing human hair roots to compare structure, function, and variation. Students extract their own hair samples and view them using a 40-power microscope objective. Differences between active/inactive phases of hair growth are readily observed. (The activity can be adapted for younger students.) (DH)

  15. Journal: Efficient Hydrologic Tracer-Test Design for Tracer-Mass Estimation and Sample Collection Frequency, 1 Method Development

    EPA Science Inventory

    Hydrological tracer testing is the most reliable diagnostic technique available for the determination of basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowl...

  16. Organizational Communication Studies: The LTT and OCD Procedures.

    ERIC Educational Resources Information Center

    Wiio, Osmo A.

    Poor results in organizational communication research may be due to the lack of comparative research, relying instead on small, unrepresentative samples from one or two organizations. Measurement techniques such as the communication audit and the network analysis make possible the comparison of different organizations and the collection of data…

  17. Investigation of Legionella Contamination in Bath Water Samples by Culture, Amoebic Co-Culture, and Real-Time Quantitative PCR Methods.

    PubMed

    Edagawa, Akiko; Kimura, Akio; Kawabuchi-Kurata, Takako; Adachi, Shinichi; Furuhata, Katsunori; Miyamoto, Hiroshi

    2015-10-19

    We investigated Legionella contamination in bath water samples, collected from 68 bathing facilities in Japan, by culture, culture with amoebic co-culture, real-time quantitative PCR (qPCR), and real-time qPCR with amoebic co-culture. Using the conventional culture method, Legionella pneumophila was detected in 11 samples (11/68, 16.2%). Contrary to our expectation, the culture method with the amoebic co-culture technique did not increase the detection rate of Legionella (4/68, 5.9%). In contrast, a combination of the amoebic co-culture technique followed by qPCR successfully increased the detection rate (57/68, 83.8%) compared with real-time qPCR alone (46/68, 67.6%). Using real-time qPCR after culture with amoebic co-culture, more than 10-fold higher bacterial numbers were observed in 30 samples (30/68, 44.1%) compared with the same samples without co-culture. On the other hand, higher bacterial numbers were not observed after propagation by amoebae in 32 samples (32/68, 47.1%). Legionella was not detected in the remaining six samples (6/68, 8.8%), irrespective of the method. These results suggest that application of the amoebic co-culture technique prior to real-time qPCR may be useful for the sensitive detection of Legionella from bath water samples. Furthermore, a combination of amoebic co-culture and real-time qPCR might be useful to detect viable and virulent Legionella because their ability to invade and multiply within free-living amoebae is considered to correlate with their pathogenicity for humans. This is the first report evaluating the efficacy of the amoebic co-culture technique for detecting Legionella in bath water samples.

  18. Investigation of Legionella Contamination in Bath Water Samples by Culture, Amoebic Co-Culture, and Real-Time Quantitative PCR Methods

    PubMed Central

    Edagawa, Akiko; Kimura, Akio; Kawabuchi-Kurata, Takako; Adachi, Shinichi; Furuhata, Katsunori; Miyamoto, Hiroshi

    2015-01-01

    We investigated Legionella contamination in bath water samples, collected from 68 bathing facilities in Japan, by culture, culture with amoebic co-culture, real-time quantitative PCR (qPCR), and real-time qPCR with amoebic co-culture. Using the conventional culture method, Legionella pneumophila was detected in 11 samples (11/68, 16.2%). Contrary to our expectation, the culture method with the amoebic co-culture technique did not increase the detection rate of Legionella (4/68, 5.9%). In contrast, a combination of the amoebic co-culture technique followed by qPCR successfully increased the detection rate (57/68, 83.8%) compared with real-time qPCR alone (46/68, 67.6%). Using real-time qPCR after culture with amoebic co-culture, more than 10-fold higher bacterial numbers were observed in 30 samples (30/68, 44.1%) compared with the same samples without co-culture. On the other hand, higher bacterial numbers were not observed after propagation by amoebae in 32 samples (32/68, 47.1%). Legionella was not detected in the remaining six samples (6/68, 8.8%), irrespective of the method. These results suggest that application of the amoebic co-culture technique prior to real-time qPCR may be useful for the sensitive detection of Legionella from bath water samples. Furthermore, a combination of amoebic co-culture and real-time qPCR might be useful to detect viable and virulent Legionella because their ability to invade and multiply within free-living amoebae is considered to correlate with their pathogenicity for humans. This is the first report evaluating the efficacy of the amoebic co-culture technique for detecting Legionella in bath water samples. PMID:26492259

  19. Distribution and environmental persistence of the causative agent of white-nose syndrome, Geomyces destructans, in bat hibernacula of the eastern United States

    USGS Publications Warehouse

    Lorch, Jeffrey M.; Muller, Laura K.; Russell, Robin E.; O'Connor, Michael; Lindner, Daniel L.; Blehert, David S.

    2013-01-01

    White-nose syndrome (WNS) is an emerging disease of hibernating bats caused by the recently described fungus Geomyces destructans. First isolated in 2008, the origins of this fungus in North America and its ability to persist in the environment remain undefined. To investigate the correlation between manifestation of WNS and distribution of G. destructans in the U.S., we analyzed sediment samples collected from 55 bat hibernacula (caves and mines) both within and outside the known range of WNS using a newly developed real-time PCR assay. Geomyces destructans was detected in 17 of 21 sites within the known range of WNS at the time the samples were collected; the fungus was not found in 28 sites beyond the known range of the disease at the time that environmental samples were collected. These data indicate that distribution of G. destructans is correlated with disease in hibernating bats and support the hypothesis that the fungus is likely an exotic species in North America. Additionally, we examined whether G. destructans persists in infested bat hibernacula when bats are absent. Sediment samples were collected from 14 WNS-positive hibernacula, and the samples were screened for viable fungus using a culture technique. Viable G. destructans was cultivated from 7 of the 14 sites sampled during late summer when bats were no longer in hibernation, suggesting the fungus can persist in the environment in the absence of bat hosts for long periods of time.

  20. [Health protection for rural workers: the need to standardize techniques for quantifying dermal exposure to pesticides].

    PubMed

    Selmi, Giuliana da Fontoura Rodrigues; Trapé, Angelo Zanaga

    2014-05-01

    Quantification of dermal exposure to pesticides in rural workers, used in risk assessment, can be performed with different techniques such as patches or whole body evaluation. However, the wide variety of methods can jeopardize the process by producing disparate results, depending on the principles in sample collection. A critical review was thus performed on the main techniques for quantifying dermal exposure, calling attention to this issue and the need to establish a single methodology for quantification of dermal exposure in rural workers. Such harmonization of different techniques should help achieve safer and healthier working conditions. Techniques that can provide reliable exposure data are an essential first step towards avoiding harm to workers' health.

  1. Predictive Techniques for Spacecraft Cabin Air Quality Control

    NASA Technical Reports Server (NTRS)

    Perry, J. L.; Cromes, Scott D. (Technical Monitor)

    2001-01-01

    As assembly of the International Space Station (ISS) proceeds, predictive techniques are used to determine the best approach for handling a variety of cabin air quality challenges. These techniques use equipment offgassing data collected from each ISS module before flight to characterize the trace chemical contaminant load. Combined with crew metabolic loads, these data serve as input to a predictive model for assessing the capability of the onboard atmosphere revitalization systems to handle the overall trace contaminant load as station assembly progresses. The techniques for predicting in-flight air quality are summarized along with results from early ISS mission analyses. Results from groundbased analyses of in-flight air quality samples are compared to the predictions to demonstrate the technique's relative conservatism.

  2. Veterinary extension on sampling techniques related to heartwater research.

    PubMed

    Steyn, H C; McCrindle, C M E; Du Toit, D

    2010-09-01

    Heartwater, a tick-borne disease caused by Ehrlichia ruminantium, is considered to be a significant cause of mortality amongst domestic and wild ruminants in South Africa. The main vector is Amblyomma hebraeum and although previous epidemiological studies have outlined endemic areas based on mortalities, these have been limited by diagnostic methods which relied mainly on positive brain smears. The indirect fluorescent antibody test (IFA) has a low specificity for heartwater organisms as it cross-reacts with some other species. Since the advent of biotechnology and genomics, molecular epidemiology has evolved using the methodology of traditional epidemiology coupled with the new molecular techniques. A new quantitative real-time polymerase chain reaction (qPCR) test has been developed for rapid and accurate diagnosis of heartwater in the live animal. This method can also be used to survey populations of A. hebraeum ticks for heartwater. Sampling whole blood and ticks for this qPCR differs from routine serum sampling, which is used for many serological tests. Veterinary field staff, particularly animal health technicians, are involved in surveillance and monitoring of controlled and other diseases of animals in South Africa. However, it was found that the sampling of whole blood was not done correctly, probably because it is a new sampling technique specific for new technology, where the heartwater organism is much more labile than the serum antibodies required for other tests. This qPCR technique is highly sensitive and can diagnose heartwater in the living animal within 2 hours, in time to treat it. Poor sampling techniques that decrease the sensitivity of the test will, however, result in a false negative diagnosis. This paper describes the development of a skills training programme for para-veterinary field staff, to facilitate research into the molecular epidemiology of heartwater in ruminants and eliminate any sampling bias due to collection errors. Humane handling techniques were also included in the training, in line with the current focus on improved livestock welfare.

  3. Geochemistry of Rock Samples Collected from the Iron Hill Carbonatite Complex, Gunnison County, Colorado

    USGS Publications Warehouse

    Van Gosen, Bradley S.

    2008-01-01

    A study conducted in 2006 by the U.S. Geological Survey collected 57 surface rock samples from nine types of intrusive rock in the Iron Hill carbonatite complex. This intrusive complex, located in Gunnison County of southwestern Colorado, is known for its classic carbonatite-alkaline igneous geology and petrology. The Iron Hill complex is also noteworthy for its diverse mineral resources, including enrichments in titanium, rare earth elements, thorium, niobium (columbium), and vanadium. This study was performed to reexamine the chemistry and metallic content of the major rock units of the Iron Hill complex by using modern analytical techniques, while providing a broader suite of elements than the earlier published studies. The report contains the geochemical analyses of the samples in tabular and digital spreadsheet format, providing the analytical results for 55 major and trace elements.

  4. Direct on-strip analysis of size- and time-resolved aerosol impactor samples using laser induced fluorescence spectra excited at 263 and 351 nm.

    PubMed

    Wang, Chuji; Pan, Yong-Le; James, Deryck; Wetmore, Alan E; Redding, Brandon

    2014-04-11

    We report a novel atmospheric aerosol characterization technique, in which dual wavelength UV laser induced fluorescence (LIF) spectrometry marries an eight-stage rotating drum impactor (RDI), namely UV-LIF-RDI, to achieve size- and time-resolved analysis of aerosol particles on-strip. The UV-LIF-RDI technique measured LIF spectra via direct laser beam illumination onto the particles that were impacted on a RDI strip with a spatial resolution of 1.2mm, equivalent to an averaged time resolution in the aerosol sampling of 3.6 h. Excited by a 263 nm or 351 nm laser, more than 2000 LIF spectra within a 3-week aerosol collection time period were obtained from the eight individual RDI strips that collected particles in eight different sizes ranging from 0.09 to 10 μm in Djibouti. Based on the known fluorescence database from atmospheric aerosols in the US, the LIF spectra obtained from the Djibouti aerosol samples were found to be dominated by fluorescence clusters 2, 5, and 8 (peaked at 330, 370, and 475 nm) when excited at 263 nm and by fluorescence clusters 1, 2, 5, and 6 (peaked at 390 and 460 nm) when excited at 351 nm. Size- and time-dependent variations of the fluorescence spectra revealed some size and time evolution behavior of organic and biological aerosols from the atmosphere in Djibouti. Moreover, this analytical technique could locate the possible sources and chemical compositions contributing to these fluorescence clusters. Advantages, limitations, and future developments of this new aerosol analysis technique are also discussed. Published by Elsevier B.V.

  5. Experimental evaluation of sand fly collection and storage methods for the isolation and molecular detection of Phlebotomus-borne viruses.

    PubMed

    Remoli, Maria Elena; Bongiorno, Gioia; Fortuna, Claudia; Marchi, Antonella; Bianchi, Riccardo; Khoury, Cristina; Ciufolini, Maria Grazia; Gramiccia, Marina

    2015-11-09

    Several viruses have been recently isolated from Mediterranean phlebotomine sand flies; some are known to cause human disease while some are new to science. To monitor the Phlebotomus-borne viruses spreading, field studies are in progress using different sand fly collection and storage methods. Two main sampling techniques consist of CDC light traps, an attraction method allowing collection of live insects in which the virus is presumed to be fairly preserved, and sticky traps, an interception method suitable to collect dead specimens in high numbers, with a risk for virus viability or integrity. Sand flies storage requires a "deep cold chain" or specimen preservation in ethanol. In the present study the influence of sand fly collection and storage methods on viral isolation and RNA detection performances was evaluated experimentally. Specimens of laboratory-reared Phlebotomus perniciosus were artificially fed with blood containing Toscana virus (family Bunyaviridae, genus Phlebovirus). Various collection and storage conditions of blood-fed females were evaluated to mimic field procedures using single and pool samples. Isolation on VERO cell cultures, quantitative Real time-Retro-transcriptase (RT)-PCR and Nested-RT-PCR were performed according to techniques commonly used in surveillance studies. Live engorged sand flies stored immediately at -80 °C were the most suitable sample for phlebovirus identification by both virus isolation and RNA detection. The viral isolation rate remained very high (26/28) for single dead engorged females frozen after 1 day, while it was moderate (10/30) for specimens collected by sticky traps maintained up to 3 days at room temperature and then stored frozen without ethanol. Opposed to viral isolation, molecular RNA detection kept very high on dead sand flies collected by sticky traps when left at room temperature up to 6 days post blood meal and then stored frozen in presence (88/95) or absence (87/88) of ethanol. Data were confirmed using sand fly pools. While the collection and storage methods investigated had not much impact on the ability to detect viral RNA by molecular methods, they affected the capacity to recover viable viruses. Consequently, sand fly collection and handling procedures should be established in advance depending on the goal of the surveillance studies.

  6. The use of the Podotrack in forensic podiatry for collection and analysis of bare footprints using the Reel method of measurement.

    PubMed

    Burrow, J Gordon

    2016-05-01

    This small-scale study examined the role that bare footprint collection and measurement processes have on the Reel method of measurement in forensic podiatry and its use in the Criminal Justice System. Previous research indicated that the Reel method was a valid and reliable measurement system for bare footprint analysis but various collection systems have been used to collect footprint data and both manual and digital measurement processes were utilized in forensic podiatry and other disciplines. This study contributes to the debate about collecting bare footprints; the techniques employed to quantify various Reel measurements and considered whether there was asymmetry between feet and footprints of the same person. An inductive, quantitative paradigm used the Podotrack gathering procedure for footprint collection and the subsequent dynamic footprints subjected to Adobe Photoshop techniques of calculating the Reel linear variables. Statistical analyses using paired-sample t tests were conducted to test hypotheses and compare data sets. Standard error of mean (SEM) showed variation between feet and the findings provide support for the Reel study and measurement method. Copyright © 2016 The Chartered Society of Forensic Sciences. Published by Elsevier Ireland Ltd. All rights reserved.

  7. A comparative study of the TF-Test®, Kato-Katz, Hoffman-Pons-Janer, Willis and Baermann-Moraes coprologic methods for the detection of human parasitosis.

    PubMed

    Carvalho, Gabriela Lanna Xavier de; Moreira, Luciano Evangelista; Pena, João Luiz; Marinho, Carolina Coimbra; Bahia, Maria Terezinha; Machado-Coelho, George Luiz Lins

    2012-02-01

    This study compares the diagnostic accuracy of the TF-Test(®) (TFT) for human parasitosis with results obtained using the traditional Kato-Katz (KK), Hoffman-Pons-Janer (HPJ), Willis and Baermann-Moraes (BM) techniques. Overall, four stool samples were taken from each individual; three alternate-day TFT stool samples and another sample that was collected in a universal container. Stool samples were taken from 331 inhabitants of the community of Quilombola Santa Cruz. The gold standard (GS) for protozoa detection was defined as the combined results for TFT, HPJ and Willis coproscopic techniques; for helminth detection, GS was defined as the combined results for all five coproscopic techniques (TFT, KK, HPJ, Willis and BM). The positivity rate of each method was compared using the McNemar test. While the TFT exhibited similar positivity rates to the GS for Entamoeba histolytica/dispar (82.4%) and Giardia duodenalis (90%), HPJ and Willis techniques exhibited significantly lower positivity rates for these protozoa. All tests exhibited significantly lower positivity rates compared with GS for the diagnosis of helminths. The KK technique had the highest positivity rate for diagnosing Schistosoma mansoni (74.6%), while the TFT had the highest positivity rates for Ascaris lumbricoides (58.1%) and hookworm (75%); HPJ technique had the highest positivity rate for Strongyloides stercoralis (50%). Although a combination of tests is the most accurate method for the diagnosis of enteral parasites, the TFT reliably estimates the prevalence of protozoa and selected helminths, such as A. lumbricoides and hookworm. Further studies are needed to evaluate the detection accuracy of the TFT in samples with varying numbers of parasites.

  8. Comparison of Selective Culturing and Biochemical Techniques for Measuring Biological Activity in Geothermal Process Fluids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pryfogle, Peter Albert

    2000-09-01

    For the past three years, scientists at the Idaho National Engineering and Environmental Laboratory have been conducting studies aimed at determining the presence and influence of bacteria found in geothermal plant cooling water systems. In particular, the efforts have been directed at understanding the conditions that lead to the growth and accumulation of biomass within these systems, reducing the operational and thermal efficiency. Initially, the methods selected were based upon the current practices used by the industry and included the collection of water quality parameters, the measurement of soluble carbon, and the use of selective medial for the determination ofmore » the number density of various types of organisms. This data has been collected on a seasonal basis at six different facilities located at the Geysers’ in Northern California. While this data is valuable in establishing biological growth trends in the facilities and providing an initial determination of upset or off-normal conditions, more detailed information about the biological activity is needed to determine what is triggering or sustaining the growth in these facilities in order to develop improved monitoring and treatment techniques. In recent years, new biochemical approaches, based upon the analyses of phospholipid fatty acids and DNA recovered from environmental samples, have been developed and commercialized. These techniques, in addition to allowing the determination of the quantity of biomass, also provide information on the community composition and the nutritional status of the organisms. During the past year, samples collected from the condenser effluents of four of the plants from The Geysers’ were analyzed using these methods and compared with the results obtained from selective culturing techniques. The purpose of this effort was to evaluate the cost-benefit of implementing these techniques for tracking microbial activity in the plant study, in place of the selective culturing analyses that are currently the industry standard.« less

  9. Biology Factual Knowledge at Eleventh Grade of Senior High School Students in Pacitan based on Favorite Schools

    NASA Astrophysics Data System (ADS)

    Yustiana, I. A.; Paidi; Mercuriani, I. S.

    2018-03-01

    This study aimed to determine the Biology factual knowledge at eleventh grade of senior high school students in Pacitan based on favorite schools. This research was a descriptive research by using survey method. The population in this study was all of senior high school students in Pacitan. The sampling technique used purposive sampling technique and obtained 3 favorite schools and 3 non-favorite schools. The technique of collecting data used test form which was as the instrument of the research. Data analysis technique used Mann-Whitney U test. Based on the test, it was obtained p = 0,000 (p <0,05) so there was a significant difference between the factual knowledge of the students in the favorite schools and non-favorite schools in Pacitan. The factual knowledge of students in favorite schools was higher with an average of 5.32 while non-favorite schools were obtained an average of 4.36.

  10. New approaches to the analysis of complex samples using fluorescence lifetime techniques and organized media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hertz, P.R.

    Fluorescence spectroscopy is a highly sensitive and selective tool for the analysis of complex systems. In order to investigate the efficacy of several steady state and dynamic techniques for the analysis of complex systems, this work focuses on two types of complex, multicomponent samples: petrolatums and coal liquids. It is shown in these studies dynamic, fluorescence lifetime-based measurements provide enhanced discrimination between complex petrolatum samples. Additionally, improved quantitative analysis of multicomponent systems is demonstrated via incorporation of organized media in coal liquid samples. This research provides the first systematic studies of (1) multifrequency phase-resolved fluorescence spectroscopy for dynamic fluorescence spectralmore » fingerprinting of complex samples, and (2) the incorporation of bile salt micellar media to improve accuracy and sensitivity for characterization of complex systems. In the petroleum studies, phase-resolved fluorescence spectroscopy is used to combine spectral and lifetime information through the measurement of phase-resolved fluorescence intensity. The intensity is collected as a function of excitation and emission wavelengths, angular modulation frequency, and detector phase angle. This multidimensional information enhances the ability to distinguish between complex samples with similar spectral characteristics. Examination of the eigenvalues and eigenvectors from factor analysis of phase-resolved and steady state excitation-emission matrices, using chemometric methods of data analysis, confirms that phase-resolved fluorescence techniques offer improved discrimination between complex samples as compared with conventional steady state methods.« less

  11. Data in support of the detection of genetically modified organisms (GMOs) in food and feed samples.

    PubMed

    Alasaad, Noor; Alzubi, Hussein; Kader, Ahmad Abdul

    2016-06-01

    Food and feed samples were randomly collected from different sources, including local and imported materials from the Syrian local market. These included maize, barley, soybean, fresh food samples and raw material. GMO detection was conducted by PCR and nested PCR-based techniques using specific primers for the most used foreign DNA commonly used in genetic transformation procedures, i.e., 35S promoter, T-nos, epsps, cryIA(b) gene and nptII gene. The results revealed for the first time in Syria the presence of GM foods and feeds with glyphosate-resistant trait of P35S promoter and NOS terminator in the imported soybean samples with high frequency (5 out of the 6 imported soybean samples). While, tests showed negative results for the local samples. Also, tests revealed existence of GMOs in two imported maize samples detecting the presence of 35S promoter and nos terminator. Nested PCR results using two sets of primers confirmed our data. The methods applied in the brief data are based on DNA analysis by Polymerase Chain Reaction (PCR). This technique is specific, practical, reproducible and sensitive enough to detect up to 0.1% GMO in food and/or feedstuffs. Furthermore, all of the techniques mentioned are economic and can be applied in Syria and other developing countries. For all these reasons, the DNA-based analysis methods were chosen and preferred over protein-based analysis.

  12. Gas composition of the January 1983 eruption of Kilauea Volcano, Hawaii

    USGS Publications Warehouse

    Greenland, L.P.

    1984-01-01

    Gas collections were made from a ???900??C vent both by conventional evacuated-bottle/wet-chemical techniques and by manual pumping of flowthrough bottles. The complete analyses suggest an equilibrium assemblage quenched at 1,010??C, about midway between fountain and vent temperatures. I suggest that the very low C S ratio is due to degassing of CO2 during storage of the magma in a shallow reservoir before eruption. The two sampling techniques yielded analytical data in mutual agreement. ?? 1984.

  13. Flexible Plasmonic Sensors

    PubMed Central

    Shir, Daniel; Ballard, Zachary S.; Ozcan, Aydogan

    2016-01-01

    Mechanical flexibility and the advent of scalable, low-cost, and high-throughput fabrication techniques have enabled numerous potential applications for plasmonic sensors. Sensitive and sophisticated biochemical measurements can now be performed through the use of flexible plasmonic sensors integrated into existing medical and industrial devices or sample collection units. More robust sensing schemes and practical techniques must be further investigated to fully realize the potentials of flexible plasmonics as a framework for designing low-cost, embedded and integrated sensors for medical, environmental, and industrial applications. PMID:27547023

  14. Simulated In Situ Determination of Soil Profile Organic and Inorganic Carbon With LIBS and VisNIR

    NASA Astrophysics Data System (ADS)

    Bricklemyer, R. S.; Brown, D. J.; Clegg, S. M.; Barefield, J. E.

    2008-12-01

    There is growing need for rapid, accurate, and inexpensive methods to measure, and verify soil organic carbon (SOC) change for national greenhouse gas accounting and the development of a soil carbon trading market. Laser Induced Breakdown Spectroscopy (LIBS) and Visible and Near Infrared Spectroscopy (VisNIR) are complementary analytical techniques that have the potential to fill that need. The LIBS method provides precise elemental analysis of soils, but generally cannot distinguish between organic C and inorganic C. VisNIR has been established as a viable technique for measuring soil properties including SOC and inorganic carbon (IC). As part of the Big Sky Carbon Sequestration Regional Partnership, 240 intact core samples (3.8 x 50 cm) have been collected from six agricultural fields in north central Montana, USA. Each of these core samples were probed concurrently with LIBS and VisNIR at 2.5, 7.5, 12.5, 17.5, 22.5, 27.5, 35 and 45 cm (+/- 1.5 cm) depths. VisNIR measurements were taken using an Analytical Spectral Devices (ASD, Boulder, CO, USA) Agrispec spectrometer to determine the partition of SOC vs. IC in the samples. The LIBS scans were collected with the LANL LIBS Core Scanner Instrument which collected the entire 200 - 900 nm plasma emission including the 247.8 nm carbon emission line. This instrument also collected the emission from the elements typically found in inorganic carbon (Ca and Mg) and organic carbon (H, O, and N). Subsamples of soil (~ 4 g) were taken from interrogation points for laboratory determination of SOC and IC. Using this analytical data, we constructed several full spectrum multivariate VisNIR/LIBS calibration models for SOC and IC. These models were then applied to independent validation cores for model evaluation.

  15. Particulate matter emission by a vehicle running on unpaved road

    NASA Astrophysics Data System (ADS)

    Williams, David Scott; Shukla, Manoj K.; Ross, Jim

    2008-05-01

    The particulate matter (PM) emission from unpaved roads starts with the pulverization of surface material by the force of the vehicle, uplifting and subsequent exposure of road to strong air currents behind the wheels. The objectives of the project were to: demonstrate the utility of a simple technique for collecting suspended airborne PM emitted by vehicle running on an unpaved road, determine the mass balance of airborne PM at different heights, and determine the particle size and elemental composition of PM. We collected dust samples on sticky tapes using a rotorod sampler mounted on a tower across an unpaved road located at the Leyendecker Plant Sciences Research Center, Las Cruces, NM, USA. Dust samples were collected at 1.5, 4.5 and 6 m height above the ground surface on the east and west side of the road. One rotorod sampler was also installed at the centre of the road at 6 m height. Dust samples from unpaved road were mostly (70%) silt and clay-sized particles and were collected at all heights. The height and width of the PM plume and the amount of clay-sized particles captured on both sides of the road increased with speed and particle captured ranged from 0.05 to 159 μm. Dust particles between PM10 and PM2.5 did not correlate with vehicle speed but particles ⩽PM2.5 did. Emission factors estimated for the total suspended PM were 10147 g km-1 at 48 km h-1 and 11062 g km-1 at 64 km h-1 speed, respectively. The predominant elements detected in PM were carbon, aluminum and silica at all heights. Overall, sticky tape method coupled with electron microscopy was a useful technique for a rapid particle size and elemental characterization of airborne PM.

  16. Signal detection theory and vestibular perception: III. Estimating unbiased fit parameters for psychometric functions.

    PubMed

    Chaudhuri, Shomesh E; Merfeld, Daniel M

    2013-03-01

    Psychophysics generally relies on estimating a subject's ability to perform a specific task as a function of an observed stimulus. For threshold studies, the fitted functions are called psychometric functions. While fitting psychometric functions to data acquired using adaptive sampling procedures (e.g., "staircase" procedures), investigators have encountered a bias in the spread ("slope" or "threshold") parameter that has been attributed to the serial dependency of the adaptive data. Using simulations, we confirm this bias for cumulative Gaussian parametric maximum likelihood fits on data collected via adaptive sampling procedures, and then present a bias-reduced maximum likelihood fit that substantially reduces the bias without reducing the precision of the spread parameter estimate and without reducing the accuracy or precision of the other fit parameters. As a separate topic, we explain how to implement this bias reduction technique using generalized linear model fits as well as other numeric maximum likelihood techniques such as the Nelder-Mead simplex. We then provide a comparison of the iterative bootstrap and observed information matrix techniques for estimating parameter fit variance from adaptive sampling procedure data sets. The iterative bootstrap technique is shown to be slightly more accurate; however, the observed information technique executes in a small fraction (0.005 %) of the time required by the iterative bootstrap technique, which is an advantage when a real-time estimate of parameter fit variance is required.

  17. Performance evaluation of laser induced breakdown spectroscopy in the measurement of liquid and solid samples

    NASA Astrophysics Data System (ADS)

    Bilge, Gonca; Sezer, Banu; Boyaci, Ismail Hakki; Eseller, Kemal Efe; Berberoglu, Halil

    2018-07-01

    Liquid analysis by using LIBS is a complicated process due to difficulties encountered during the collection of light and formation of plasma in liquid. To avoid these, some applications are performed such as aerosol formation and transforming liquid into solid state. However, performance of LIBS in liquid samples still remains a challenging issue. In this study, performance evaluation of LIBS and parameter optimizations in liquid and solid phase samples were performed. For this purpose, milk was chosen as model sample; milk powder was used as solid sample, and milk was used as liquid sample in the experiments. Different experimental setups have been constructed for each sampling technique, and optimizations were performed to determine suitable parameters such as delay time, laser energy, repetition rate and speed of rotary table for solid sampling technique, and flow rate of carrier gas for liquid sampling technique. Target element was determined as Ca, which is a critically important element in milk for determining its nutritional value and Ca addition. In optimum parameters, limit of detection (LOD), limit of quantification (LOQ) and relative standard deviation (RSD) values were calculated as 0.11%, 0.36% and 8.29% respectively for milk powders samples; while LOD, LOQ and RSD values were calculated as 0.24%, 0.81%, and 10.93% respectively for milk samples. It can be said that LIBS is an applicable method in both liquid and solid samples with suitable systems and parameters. However, liquid analysis requires much more developed systems for more accurate results.

  18. Characterization of Dust on Solar Devices in Southern Nevada =

    NASA Astrophysics Data System (ADS)

    Sylva, Jason R.

    Dust can impact the efficiency of solar energy collection devices, and in some arid environments, dust can reduce solar energy efficiency up to 30%. Reducing the impact of dust is therefore critical in the expansion of solar technology throughout regions where solar energy is utilized. Characterization of suspended and settled particulate matter can assist in developing strategies for dust mitigation. With the characterization of suspended and settled particulate in remote, rural, and urban environments, more informed decisions can be made regarding the selection of coating material on solar panels as well as developing cleaning and maintenance procedures. Particulate matter that deposits on a solar surface can potentially interact with solar radiation, precipitation, or even directly with the surface material itself. These interactions could lead to the formation of coatings that reduce/block radiation and/or degrade the integrity of the surface. When you extrapolate these possibilities to a larger scale preliminary characterization of dust will play a vital role when planning the construction of a solar energy facility. A variety of sampling techniques were employed to obtain particulate matter for characterization. These included direct collection of particulates from solar surfaces: via vacuum and wipe sample collection on panels, tacky dot adhesive slides and plain slides that were exposed at different intervals, desert vugs that are natural particulate collectors, as well as high volume air sampling for collection of suspended particulates. High volume air sampling was performed using glass fiber filters and 2 micron stainless steel screens. Direct collection of settled particulates was performed by sampling from solar surfaces, vugs, and by collection on exposed glass surfaces. Collection onto glass surfaces was achieved by setting up a plain microscope slide, tacky dot slides, and panes of glass. The sampling methodology allowed for the collection of samples for analyses using various analytical methods that included Raman microspectroscopy, pyrolysis gas chromatography mass spectrometry, ion chromatography and inductively coupled plasma mass spectrometry. These various methods allow for identification of organic and inorganic components as well the mineral distribution of suspended and settled particulate material. None None None None None

  19. Evaluation and comparison of FTA card and CTAB DNA extraction methods for non-agricultural taxa.

    PubMed

    Siegel, Chloe S; Stevenson, Florence O; Zimmer, Elizabeth A

    2017-02-01

    An efficient, effective DNA extraction method is necessary for comprehensive analysis of plant genomes. This study analyzed the quality of DNA obtained using paper FTA cards prepared directly in the field when compared to the more traditional cetyltrimethylammonium bromide (CTAB)-based extraction methods from silica-dried samples. DNA was extracted using FTA cards according to the manufacturer's protocol. In parallel, CTAB-based extractions were done using the automated AutoGen DNA isolation system. DNA quality for both methods was determined for 15 non-agricultural species collected in situ, by gel separation, spectrophotometry, fluorometry, and successful amplification and sequencing of nuclear and chloroplast gene markers. The FTA card extraction method yielded less concentrated, but also less fragmented samples than the CTAB-based technique. The card-extracted samples provided DNA that could be successfully amplified and sequenced. The FTA cards are also useful because the collected samples do not require refrigeration, extensive laboratory expertise, or as many hazardous chemicals as extractions using the CTAB-based technique. The relative success of the FTA card method in our study suggested that this method could be a valuable tool for studies in plant population genetics and conservation biology that may involve screening of hundreds of individual plants. The FTA cards, like the silica gel samples, do not contain plant material capable of propagation, and therefore do not require permits from the U.S. Department of Agriculture (USDA) Animal and Plant Health Inspection Service (APHIS) for transportation.

  20. Assessment of sample preservation techniques for pharmaceuticals, personal care products, and steroids in surface and drinking water.

    PubMed

    Vanderford, Brett J; Mawhinney, Douglas B; Trenholm, Rebecca A; Zeigler-Holady, Janie C; Snyder, Shane A

    2011-02-01

    Proper collection and preservation techniques are necessary to ensure sample integrity and maintain the stability of analytes until analysis. Data from improperly collected and preserved samples could lead to faulty conclusions and misinterpretation of the occurrence and fate of the compounds being studied. Because contaminants of emerging concern, such as pharmaceuticals and personal care products (PPCPs) and steroids, generally occur in surface and drinking water at ng/L levels, these compounds in particular require such protocols to accurately assess their concentrations. In this study, sample bottle types, residual oxidant quenching agents, preservation agents, and hold times were assessed for 21 PPCPs and steroids in surface water and finished drinking water. Amber glass bottles were found to have the least effect on target analyte concentrations, while high-density polyethylene bottles had the most impact. Ascorbic acid, sodium thiosulfate, and sodium sulfite were determined to be acceptable quenching agents and preservation with sodium azide at 4 °C led to the stability of the most target compounds. A combination of amber glass bottles, ascorbic acid, and sodium azide preserved analyte concentrations for 28 days in the tested matrices when held at 4 °C. Samples without a preservation agent were determined to be stable for all but two of the analytes when stored in amber glass bottles at 4 °C for 72 h. Results suggest that if improper protocols are utilized, reported concentrations of target PPCPs and steroids may be inaccurate.

Top