Sample records for sample evaluation instruments

  1. Rmax: A systematic approach to evaluate instrument sort performance using center stream catch☆

    PubMed Central

    Riddell, Andrew; Gardner, Rui; Perez-Gonzalez, Alexis; Lopes, Telma; Martinez, Lola

    2015-01-01

    Sorting performance can be evaluated with regard to Purity, Yield and/or Recovery of the sorted fraction. Purity is a check on the quality of the sample and the sort decisions made by the instrument. Recovery and Yield definitions vary with some authors regarding both as how efficient the instrument is at sorting the target particles from the original sample, others distinguishing Recovery from Yield, where the former is used to describe the accuracy of the instrument’s sort count. Yield and Recovery are often neglected, mostly due to difficulties in their measurement. Purity of the sort product is often cited alone but is not sufficient to evaluate sorting performance. All of these three performance metrics require re-sampling of the sorted fraction. But, unlike Purity, calculating Yield and/or Recovery calls for the absolute counting of particles in the sorted fraction, which may not be feasible, particularly when dealing with rare populations and precious samples. In addition, the counting process itself involves large errors. Here we describe a new metric for evaluating instrument sort Recovery, defined as the number of particles sorted relative to the number of original particles to be sorted. This calculation requires only measuring the ratios of target and non-target populations in the original pre-sort sample and in the waste stream or center stream catch (CSC), avoiding re-sampling the sorted fraction and absolute counting. We called this new metric Rmax, since it corresponds to the maximum expected Recovery for a particular set of instrument parameters. Rmax is ideal to evaluate and troubleshoot the optimum drop-charge delay of the sorter, or any instrument related failures that will affect sort performance. It can be used as a daily quality control check but can be particularly useful to assess instrument performance before single-cell sorting experiments. Because we do not perturb the sort fraction we can calculate Rmax during the sort process, being especially valuable to check instrument performance during rare population sorts. PMID:25747337

  2. An evaluation of Brix refractometry instruments for measurement of colostrum quality in dairy cattle.

    PubMed

    Bielmann, V; Gillan, J; Perkins, N R; Skidmore, A L; Godden, S; Leslie, K E

    2010-08-01

    Acquisition of high quality colostrum is an important factor influencing neonatal calf health. Many methods have been used to assess the Ig concentration of colostrum; however, improved, validated evaluation tools are needed. The aims of this study were to evaluate both optical and digital Brix refractometer instruments for the measurement of Ig concentration of colostrum as compared with the gold standard radial immunodiffusion assay laboratory assessment and to determine the correlation between Ig measurements taken from fresh and frozen colostrum samples for both Brix refractometer instruments. This research was completed using 288 colostrum samples from 3 different farms. It was concluded that the optical and digital Brix refractometers were highly correlated for both fresh and frozen samples (r=0.98 and r=0.97, respectively). Correlation between both refractometer instruments for fresh and frozen samples and the gold standard radial immunodiffusion assay were determined to be very similar, with a correlation coefficient between 0.71 and 0.74. Both instruments exhibited excellent test characteristics, indicating an appropriate cut-off point of 22% Brix score for the identification of good quality colostrum. Copyright (c) 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. Investigations related to evaluation of ultramicrofluorometer

    NASA Technical Reports Server (NTRS)

    Whitcomb, B.

    1981-01-01

    High resolution emission and excitation fluorescent spectra were obtained for several samples in an effort to determine the optimum operational design for the instrument. The instrument was used to determine the required nature of a sample which could be detected, and in so doing, several different sample preparation techniques were considered. Numerous experiments were performed to determine the capabilities of the instrument with regard to the detection of suitably prepared virus specimens. Significant results were obtained in several areas. The fluorescent spectra indicated that substantial changes in the laser might be used advantageously to greatly improve the performance of the instrument. In the existing configuration, the instrument was shown to be capable of detecting the presence of suitably prepared virus samples.

  4. A Comparison of Screening Instruments: Predictive Validity of the BESS and BSC

    ERIC Educational Resources Information Center

    King, Kathleen R.; Reschly, Amy L.

    2014-01-01

    The purpose of this study was to evaluate and compare two behavior screening instruments--the Behavioral and Emotional Screening System and the Behavior Screening Checklist. The sample consisted of 492 elementary school children from the southeastern United States. The psychometric properties of the screening instruments were evaluated in terms of…

  5. The Effects of Instrumentation on Urine Cytology and CK-20 Analysis for the Detection of Bladder Cancer.

    PubMed

    Wegelin, Olivier; Bartels, Diny W M; Tromp, Ellen; Kuypers, Karel C; van Melick, Harm H E

    2015-10-01

    To evaluate the effects of cystoscopy on urine cytology and additional cytokeratin-20 (CK-20) staining in patients presenting with gross hematuria. For 83 patients presenting with gross hematuria, spontaneous and instrumented paired urine samples were analyzed. Three patients were excluded. Spontaneous samples were collected within 1 hour before cystoscopy, and the instrumented samples were tapped through the cystoscope. Subsequently, patients underwent cystoscopic evaluation and imaging of the urinary tract. If tumor suspicious lesions were found on cystoscopy or imaging, subjects underwent transurethral resection or ureterorenoscopy. Two blinded uropathological reviewers (DB, KK) evaluated 160 urine samples. Reference standards were results of cystoscopy, imaging, or histopathology. Thirty-seven patients (46.3%) underwent transurethral resection or ureterorenoscopy procedures. In 30 patients (37.5%) tumor presence was confirmed by histopathology. The specificity of urine analysis was significantly higher for spontaneous samples than instrumented samples for both cytology alone (94% vs 72%, P = .01) and for cytology combined with CK-20 analysis (98% vs 84%, P = .02). The difference in sensitivity between spontaneous and instrumented samples was not significant for both cytology alone (40% vs 53%) and combined with CK-20 analysis (67% vs 67%). The addition of CK-20 analysis to cytology significantly increases test sensitivity in spontaneous urine cytology (67% vs 40%, P = .03). Instrumentation significantly decreases specificity of urine cytology. This may lead to unnecessary diagnostic procedures. Additional CK-20 staining in spontaneous urine cytology significantly increases sensitivity but did not improve the already high specificity. We suggest performing urine cytology and CK-20 analysis on spontaneously voided urine. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    EPA Pesticide Factsheets

    The Rigaku ZSX Mini II (ZSX Mini II) XRF Services x-ray fluorescence (XRF) analyzer was demon-strated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the ZSX Mini II analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the ZSX Mini II analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as spiked samples with certified element con

  7. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    EPA Pesticide Factsheets

    The Rontec PicoTAX x-ray fluorescence (XRF) analyzer was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the PicoTAX analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the PicoTAX analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as spiked samples with certified element concentrations. Accuracy was assessed by c

  8. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    EPA Pesticide Factsheets

    The Niton XLt 700 Series (XLt) XRF Services x-ray fluorescence (XRF) analyzer was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the XLt analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the XLt analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as spiked samples with certified element concentrations. Accuracy

  9. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    EPA Pesticide Factsheets

    The Oxford ED2000 x-ray fluorescence (XRF) analyzer was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the ED2000 analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the ED2000 analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as spiked samples with certified element concentrations. Accuracy was assessed by com

  10. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    EPA Pesticide Factsheets

    The Innov-X XT400 Series (XT400) x-ray fluorescence (XRF) analyzer was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the XT400 analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the XT400 analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as spiked samples with certified element concentrations. Accuracy was as

  11. An Integrative Review of Self-Efficacy Measurement Instruments in Youth with Type 1 Diabetes (T1DM)

    PubMed Central

    Rasbach, Lisa; Jenkins, Carolyn; Laffel, Lori

    2014-01-01

    Purpose The purpose of this study is to assess the extant literature on instruments used to measure self-efficacy in youth with type 1 diabetes (T1DM) and their caregivers and to critically evaluate these measurements. Methods An integrative review (2003–2013) was conducted searching PsycINFO, Cumulative Index to Nursing and Allied Health Literature (CINAHL), and U.S. National Library of Medicine PubMed service (PubMed) databases using key words diabetes, type 1 diabetes, and self-efficacy. The authors reviewed the resulting294 references for inclusion criteria of (a) sample of youth with T1DM or sample of caregivers of youth with T1DM, (b) description of the self-efficacy instrument as primary research, and (c) the instrument measured self-efficacy specifically related to diabetes management. Forty-five articles out of the initial 294 met criteria. Results Of the 45 articles, 10 different self-efficacy instruments were identified. The primary theoretical framework used was Bandura’s social cognitive theory and model of self-efficacy. Most participants were white middle class T1DM youth. Evaluations to assess validity often were not reported; however, a majority of studies reported high internal consistency of the instruments. Conclusions Sample homogeneity could limit the applicability of results to certain patient populations. Further psychometric analysis, including validity assessments, should be conducted in more diverse samples. Development of valid and reliable instruments for measuring self-efficacy that are sensitive to change across a wider caregiver base over time is necessary. While this review examined reliable and valid instruments used in research, future opportunities include evaluation of measuring self-efficacy in T1DM youth exposed to recent advances in diabetes management technologies. PMID:25216655

  12. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    EPA Pesticide Factsheets

    The Elvatech, Ltd. ElvaX (ElvaX) x-ray fluorescence (XRF) analyzer distributed in the United States by Xcalibur XRF Services (Xcalibur), was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the ElvaX analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the ElvaX analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as s

  13. Autoclave sterilization of instruments used on women with cervical neoplasia is an effective method of eradicating residual human papillomavirus DNA: a polymerase chain reaction-based evaluation.

    PubMed

    Estes, Jacob M; Kirby, Tyler O; Huh, Warner K

    2007-01-01

    To determine whether autoclave sterilization eradicates human papillomavirus (HPV) DNA on specula and instruments used to treat women with cervical neoplasia. Specula and instruments used in two referral colposcopy clinics were evaluated to determine the PGMY9/11 primer system's ability to amplify residual HPV DNA. Each speculum and instrument was sampled with a Dacron swab and stored in PreservCyt solution (Cytyc Corporation, Marlborough, MA) at 4 degrees C. DNA amplification was performed under standard conditions with appropriate controls followed by HPV typing using the reverse line blot test (Roche Molecular Systems, Alameda, CA). Once validated, the same polymerase chain reaction method was used on autoclave-sterilized specula and biopsy instruments and heated glass bead- and Cidex bath (Johnson & Johnson, New Brunswick, NJ)-sterilized instruments. All results, with appropriate positive and negative controls, were confirmed in triplicate. A total of 140 instruments (70 used and 70 autoclaved) were sampled for residual HPV DNA. Five samples in the contaminated specula arm were excluded from analysis secondary to insufficient sampling. Of the remaining samples, 52.3% (34/65) of contaminated instruments-both specula and biopsy instruments-had detectable HPV DNA. Fifty-five percent of contaminated biopsy instruments (11/20) were positive and 51.1% of contaminated specula (23/45) were positive. All 70 autoclaved samples (50 specula and 20 biopsy instruments) were negative for residual HPV DNA or beta-globin. One instrument in the glass bead and Cidex group that was presumed sterile was positive for HPV 16 DNA. The PGMY9/11 primer system is an effective method to detect residual HPV DNA. Autoclave sterilization appears to eradicate HPV DNA to levels undetectable with this sensitive assay, whereas heated glass beads followed by Cidex bath appears to be inadequate methods. These results suggest that autoclave sterilization is effective when using nondisposable instruments and should be the method of choice in studies using polymerase chain reaction-based amplification of HPV DNA.

  14. [Evaluation of Medical Instruments Cleaning Effect of Fluorescence Detection Technique].

    PubMed

    Sheng, Nan; Shen, Yue; Li, Zhen; Li, Huijuan; Zhou, Chaoqun

    2016-01-01

    To compare the cleaning effect of automatic cleaning machine and manual cleaning on coupling type surgical instruments. A total of 32 cleaned medical instruments were randomly sampled from medical institutions in Putuo District medical institutions disinfection supply center. Hygiena System SUREII ATP was used to monitor the ATP value, and the cleaning effect was evaluated. The surface ATP values of the medical instrument of manual cleaning were higher than that of the automatic cleaning machine. Coupling type surgical instruments has better cleaning effect of automatic cleaning machine before disinfection, the application is recommended.

  15. Comparative fiber evaluation of the mesdan aqualab microwave moisture measurement instrument

    USDA-ARS?s Scientific Manuscript database

    Moisture is a key cotton fiber parameter, as it can impact the fiber quality and the processing of cotton fiber. The Mesdan Aqualab is a microwave-based fiber moisture measurement instrument for samples with moderate sample size. A program was implemented to determine the capabilities of the Aqual...

  16. Evaluating Effective Teaching in College Level Economics Using Student Ratings of Instruction: A Factor Analytic Approach

    ERIC Educational Resources Information Center

    Agbetsiafa, Douglas

    2010-01-01

    This paper explores the factors that affect students' evaluation of economic instruction using a sample of 1300 completed rating instruments at a comprehensive four-year mid-western public university. The study uses factor analysis to determine the validity and reliability of the evaluation instrument in assessing instructor or course…

  17. Rapid determination of lead for industrial hygiene surveys

    NASA Astrophysics Data System (ADS)

    Schneider, E. W.; Hill, R. F.

    1982-02-01

    Emphasis on the continued reduction of personnel exposure to airborne lead has led to the development and evaluation of portable instrumentation for the rapid determination of microgram quantities of lead collected on air filter samples. The instrumentation is based on radioisotope-induced X-ray fluorescence; a cadmium-109 radioisotope source is used for sample excitation, and the characteristic lead X-rays emitted are measured by a proportional detector. The effects of excitation source geometry, particle size, and interferences from other elements were investigated. This type of portable instrumentation appears ideally suited for in-plant measurements intended to monitor lead and evaluate new control measures.

  18. INNOVATIVE TECHNOLOGY EVALUATION REPORT, SEDIMENT SAMPLING TECHNOLOGY, AQUATIC RESEARCH INSTRUMENTS, RUSSIAN PEAT BORER

    EPA Science Inventory

    The Russian Peat Borer designed and fabricated by Aquatic Research Instruments was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation Program in April and May 1999 at sites in EPA Regions 1 and 5, respectively. In additio...

  19. An item response theory evaluation of three depression assessment instruments in a clinical sample.

    PubMed

    Adler, Mats; Hetta, Jerker; Isacsson, Göran; Brodin, Ulf

    2012-06-21

    This study investigates whether an analysis, based on Item Response Theory (IRT), can be used for initial evaluations of depression assessment instruments in a limited patient sample from an affective disorder outpatient clinic, with the aim to finding major advantages and deficiencies of the instruments. Three depression assessment instruments, the depression module from the Patient Health Questionnaire (PHQ9), the depression subscale of Affective Self Rating Scale (AS-18-D) and the Montgomery-Åsberg Depression Rating Scale (MADRS) were evaluated in a sample of 61 patients with affective disorder diagnoses, mainly bipolar disorder. A '3- step IRT strategy' was used. In a first step, the Mokken non-parametric analysis showed that PHQ9 and AS-18-D had strong overall scalabilities of 0.510 [C.I. 0.42, 0.61] and 0,513 [C.I. 0.41, 0.63] respectively, while MADRS had a weak scalability of 0.339 [C.I. 0.25, 0.43]. In a second step, a Rasch model analysis indicated large differences concerning the item discriminating capacity and was therefore considered not suitable for the data. In third step, applying a more flexible two parameter model, all three instruments showed large differences in item information and items had a low capacity to reliably measure respondents at low levels of depression severity. We conclude that a stepwise IRT-approach, as performed in this study, is a suitable tool for studying assessment instruments at early stages of development. Such an analysis can give useful information, even in small samples, in order to construct more precise measurements or to evaluate existing assessment instruments. The study suggests that the PHQ9 and AS-18-D can be useful for measurement of depression severity in an outpatient clinic for affective disorder, while the MADRS shows weak measurement properties for this type of patients.

  20. Application of conductive polymer analysis for wood and woody plant identifications

    Treesearch

    A. Dan Wilson; D.G. Lester; Charisse S. Oberle

    2005-01-01

    An electronic aroma detection (EAD) technology known as conductive polymer analysis (CPA) was evaluated as a means of identifying and discriminating woody samples of angiosperms and gymnosperms using an analytical instrument (electronic nose) that characterizes the aroma profiles of volatiles released from excised wood into sampled headspace. The instrument measures...

  1. Evaluating Handheld X-Ray Fluorescence (XRF) Technology in Planetary Exploration: Demonstrating Instrument Stability and Understanding Analytical Constraints and Limits for Basaltic Rocks

    NASA Technical Reports Server (NTRS)

    Young, K. E.; Hodges, K. V.; Evans, C. A.

    2012-01-01

    While large-footprint X-ray fluorescence (XRF) instruments are reliable providers of elemental information about geologic samples, handheld XRF instruments are currently being developed that enable the collection of geochemical data in the field in short time periods (approx.60 seconds) [1]. These detectors are lightweight (1.3kg) and can provide elemental abundances of major rock forming elements heavier than Na. While handheld XRF detectors were originally developed for use in mining, we are working with commercially available instruments as prototypes to explore how portable XRF technology may enable planetary field science [2,3,4]. If an astronaut or robotic explorer visited another planetary surface, the ability to obtain and evaluate geochemical data in real-time would be invaluable, especially in the high-grading of samples to determine which should be returned to Earth. We present our results on the evaluation of handheld XRF technology as a geochemical tool in the context of planetary exploration.

  2. Evaluation of surface characteristics of rotary nickel-titanium instruments produced by different manufacturing methods.

    PubMed

    Inan, U; Gurel, M

    2017-02-01

    Instrument fracture is a serious concern in endodontic practice. The aim of this study was to investigate the surface quality of new and used rotary nickel-titanium (NiTi) instruments manufactured by the traditional grinding process and twisting methods. Total 16 instruments of two rotary NiTi systems were used in this study. Eight Twisted Files (TF) (SybronEndo, Orange, CA, USA) and 8 Mtwo (VDW, Munich, Germany) instruments were evaluated. New and used of 4 experimental groups were evaluated using an atomic force microscopy (AFM). New and used instruments were analyzed on 3 points along a 3 mm. section at the tip of the instrument. Quantitative measurements according to the topographical deviations were recorded. The data were statistically analyzed with paired samples t-test and independent samples t-test. Mean root mean square (RMS) values for new and used TF 25.06 files were 10.70 ± 2.80 nm and 21.58 ± 6.42 nm, respectively, and the difference between them was statistically significant (P < 0.05). Mean RMS values for new and used Mtwo 25.06 files were 24.16 ± 9.30 nm and 39.15 ± 16.20 nm respectively, the difference between them also was statistically significant (P < 0.05). According to the AFM analysis, instruments produced by twisting method (TF 25.06) had better surface quality than the instruments produced by traditional grinding process (Mtwo 25.06 files).

  3. [Some critical remarks on standardised assessment instruments in nursing].

    PubMed

    Bartholomeyczik, Sabine

    2007-08-01

    The use of standardised instruments in nursing has rapidly grown and can be seen as a symptom of the necessary comprehensive nursing diagnostics. However, these instruments comprise the risk of misuse, if they are not critically evaluated. Published statements about tests of reliability and validity of an instrument are insufficient. First, the critical evaluation has to ask for the instrument's theoretical and content base: Is the instrument relevant for nursing, suitable for practice and leading to nursing actions? Two examples of well known instruments and different kinds of their utilization in nursing are discussed. Next, the instruments have to be questioned as "bodies with numbers". Studies on reliability and validity have to be as carefully evaluated as other empirical research. The sample, the suitability of agreement indicators (interraterreliability), kind and reason of tests have to be questioned. The same has to be done with tests of validity which comprise an even greater challenge. Methodological studies about these questions are missing; guidelines for test user qualifications need to be developed.

  4. LIMS for Lasers 2015 for achieving long-term accuracy and precision of δ2H, δ17O, and δ18O of waters using laser absorption spectrometry

    USGS Publications Warehouse

    Coplen, Tyler B.; Wassenaar, Leonard I

    2015-01-01

    Although laser absorption spectrometry (LAS) instrumentation is easy to use, its incorporation into laboratory operations is not easy, owing to extensive offline manipulation of comma-separated-values files for outlier detection, between-sample memory correction, nonlinearity (δ-variation with water amount) correction, drift correction, normalization to VSMOW-SLAP scales, and difficulty in performing long-term QA/QC audits. METHODS: A Microsoft Access relational-database application, LIMS (Laboratory Information Management System) for Lasers 2015, was developed. It automates LAS data corrections and manages clients, projects, samples, instrument-sample lists, and triple-isotope (δ(17) O, δ(18) O, and δ(2) H values) instrumental data for liquid-water samples. It enables users to (1) graphically evaluate sample injections for variable water yields and high isotope-delta variance; (2) correct for between-sample carryover, instrumental drift, and δ nonlinearity; and (3) normalize final results to VSMOW-SLAP scales. RESULTS: Cost-free LIMS for Lasers 2015 enables users to obtain improved δ(17) O, δ(18) O, and δ(2) H values with liquid-water LAS instruments, even those with under-performing syringes. For example, LAS δ(2) HVSMOW measurements of USGS50 Lake Kyoga (Uganda) water using an under-performing syringe having ±10 % variation in water concentration gave +31.7 ± 1.6 ‰ (2-σ standard deviation), compared with the reference value of +32.8 ± 0.4 ‰, after correction for variation in δ value with water concentration, between-sample memory, and normalization to the VSMOW-SLAP scale. CONCLUSIONS: LIMS for Lasers 2015 enables users to create systematic, well-founded instrument templates, import δ(2) H, δ(17) O, and δ(18) O results, evaluate performance with automatic graphical plots, correct for δ nonlinearity due to variable water concentration, correct for between-sample memory, adjust for drift, perform VSMOW-SLAP normalization, and perform long-term QA/QC audits easily.

  5. Reliability and construct validity of the Participation in Life Activities Scale for children and adolescents with asthma: an instrument evaluation study.

    PubMed

    Kintner, Eileen K; Sikorskii, Alla

    2008-06-04

    The purpose of this study was to evaluate the reliability and construct validity of the Participation in Life Activities Scale, an instrument designed to measure older school-age child and early adolescent level of involvement in chosen pursuits. A cross-sectional design was used. The convenience sample consisted of 313 school-age children and early adolescents with asthma, ages 9-15 years. The self-report summative scale of interest is a 3-indicator survey. Higher scores are reflective of higher levels of participation. Internal consistency reliability and construct validity for the entire sample and sub groups of the sample were evaluated. The instrument was deemed sound for the entire sample as well as sub groups based on sex, race, age, socioeconomic status, and severity of illness. Cronbach's alpha coefficient for internal consistency reliability for the entire sample was .74. Exploratory factor analysis indicated a single component solution (loadings .79-.85) accounting for 66% of the explained variance. Construct validity was established by testing the posed relationship between participation in life activities scores and severity of illness. Confirmatory factor analysis revealed a good fit between the data and specified model, chi2(10, n = 302) = 8.074, p = .62. This instrument could be used (a) in clinical settings to diagnose restricted participation in desired activities, guide decision-making about treatment plans to increase participation, and motivate behavioral change in the management of asthma; and (b) in research settings to explore factors influencing and consequences of restricted and unrestricted participation, and as an outcome measure to evaluate the effectiveness of programs designed to foster child and early adolescent management of asthma.

  6. Smoking and Body Weight: Evidence using Genetic Instruments

    PubMed Central

    Wehby, George; Murray, Jeffrey C.; Wilcox, Allen; Lie, Rolv T.

    2011-01-01

    Several studies have evaluated whether the high and rising obesity rates over the past three decades may be due to the declining smoking rates. There is mixed evidence across studies – some find negative smoking effects and positive cigarette cost effects on body weight, while others find opposite effects. This study applies a unique approach to identify the smoking effects on body weight and to evaluate the heterogeneity in these effects across the body mass index (BMI) distribution by utilizing genetic instruments for smoking. Using a data sample of 1,057 mothers from Norway, the study finds heterogeneous effects of cigarette smoking on BMI – smoking increases BMI at low/moderate BMI levels and decreases BMI at high BMI levels. The study highlights the potential advantages and challenges of employing genetic instrumental variables to identify behavior effects including the importance of qualifying the instruments and the need for large samples. PMID:22024417

  7. Assessing the heterogeneity of aggressive behavior traits: exploratory and confirmatory analyses of the reactive and instrumental aggression Personality Assessment Inventory (PAI) scales.

    PubMed

    Antonius, Daniel; Sinclair, Samuel Justin; Shiva, Andrew A; Messinger, Julie W; Maile, Jordan; Siefert, Caleb J; Belfi, Brian; Malaspina, Dolores; Blais, Mark A

    2013-01-01

    The heterogeneity of violent behavior is often overlooked in risk assessment despite its importance in the management and treatment of psychiatric and forensic patients. In this study, items from the Personality Assessment Inventory (PAI) were first evaluated and rated by experts in terms of how well they assessed personality features associated with reactive and instrumental aggression. Exploratory principal component analyses (PCA) were then conducted on select items using a sample of psychiatric and forensic inpatients (n = 479) to examine the latent structure and construct validity of these reactive and instrumental aggression factors. Finally, a confirmatory factor analysis (CFA) was conducted on a separate sample of psychiatric inpatients (n = 503) to evaluate whether these factors yielded acceptable model fit. Overall, the exploratory and confirmatory analyses supported the existence of two latent PAI factor structures, which delineate personality traits related to reactive and instrumental aggression.

  8. Evaluation of portable Raman spectrometer with 1064 nm excitation for geological and forensic applications.

    PubMed

    Vítek, Petr; Ali, Esam M A; Edwards, Howell G M; Jehlička, Jan; Cox, Rick; Page, Kristian

    2012-02-01

    The development of miniaturized Raman instrumentation is in demand for applications relevant to forensic, pharmaceutical and art analyses, as well as geosciences, and planetary exploration. In this study we report on evaluation of a portable dispersive Raman spectrometer equipped with 1064 nm laser excitation. Selected samples from geological, geobiological and forensic areas of interest have been studied from which the advantages, disadvantages and the analytical potential of the instrument are assessed based on a comparison with bench instrumentation and other portable Raman spectrometers using 785 nm excitation. It is demonstrated that the instrument operating with 1064 nm excitation has potential for expanding the number and types of samples that can be measured by miniaturized Raman spectroscopy without interfering fluorescence background emission. It includes inorganic and organic minerals, biomolecules within living lichen and endolithic cyanobacteria as well as drugs of abuse and explosives. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Evaluation of portable Raman spectrometer with 1064 nm excitation for geological and forensic applications

    NASA Astrophysics Data System (ADS)

    Vítek, Petr; Ali, Esam M. A.; Edwards, Howell G. M.; Jehlička, Jan; Cox, Rick; Page, Kristian

    2012-02-01

    The development of miniaturized Raman instrumentation is in demand for applications relevant to forensic, pharmaceutical and art analyses, as well as geosciences, and planetary exploration. In this study we report on evaluation of a portable dispersive Raman spectrometer equipped with 1064 nm laser excitation. Selected samples from geological, geobiological and forensic areas of interest have been studied from which the advantages, disadvantages and the analytical potential of the instrument are assessed based on a comparison with bench instrumentation and other portable Raman spectrometers using 785 nm excitation. It is demonstrated that the instrument operating with 1064 nm excitation has potential for expanding the number and types of samples that can be measured by miniaturized Raman spectroscopy without interfering fluorescence background emission. It includes inorganic and organic minerals, biomolecules within living lichen and endolithic cyanobacteria as well as drugs of abuse and explosives.

  10. Potential sources of analytical bias and error in selected trace element data-quality analyses

    USGS Publications Warehouse

    Paul, Angela P.; Garbarino, John R.; Olsen, Lisa D.; Rosen, Michael R.; Mebane, Christopher A.; Struzeski, Tedmund M.

    2016-09-28

    Potential sources of analytical bias and error associated with laboratory analyses for selected trace elements where concentrations were greater in filtered samples than in paired unfiltered samples were evaluated by U.S. Geological Survey (USGS) Water Quality Specialists in collaboration with the USGS National Water Quality Laboratory (NWQL) and the Branch of Quality Systems (BQS).Causes for trace-element concentrations in filtered samples to exceed those in associated unfiltered samples have been attributed to variability in analytical measurements, analytical bias, sample contamination either in the field or laboratory, and (or) sample-matrix chemistry. These issues have not only been attributed to data generated by the USGS NWQL but have been observed in data generated by other laboratories. This study continues the evaluation of potential analytical bias and error resulting from matrix chemistry and instrument variability by evaluating the performance of seven selected trace elements in paired filtered and unfiltered surface-water and groundwater samples collected from 23 sampling sites of varying chemistries from six States, matrix spike recoveries, and standard reference materials.Filtered and unfiltered samples have been routinely analyzed on separate inductively coupled plasma-mass spectrometry instruments. Unfiltered samples are treated with hydrochloric acid (HCl) during an in-bottle digestion procedure; filtered samples are not routinely treated with HCl as part of the laboratory analytical procedure. To evaluate the influence of HCl on different sample matrices, an aliquot of the filtered samples was treated with HCl. The addition of HCl did little to differentiate the analytical results between filtered samples treated with HCl from those samples left untreated; however, there was a small, but noticeable, decrease in the number of instances where a particular trace-element concentration was greater in a filtered sample than in the associated unfiltered sample for all trace elements except selenium. Accounting for the small dilution effect (2 percent) from the addition of HCl, as required for the in-bottle digestion procedure for unfiltered samples, may be one step toward decreasing the number of instances where trace-element concentrations are greater in filtered samples than in paired unfiltered samples.The laboratory analyses of arsenic, cadmium, lead, and zinc did not appear to be influenced by instrument biases. These trace elements showed similar results on both instruments used to analyze filtered and unfiltered samples. The results for aluminum and molybdenum tended to be higher on the instrument designated to analyze unfiltered samples; the results for selenium tended to be lower. The matrices used to prepare calibration standards were different for the two instruments. The instrument designated for the analysis of unfiltered samples was calibrated using standards prepared in a nitric:hydrochloric acid (HNO3:HCl) matrix. The instrument designated for the analysis of filtered samples was calibrated using standards prepared in a matrix acidified only with HNO3. Matrix chemistry may have influenced the responses of aluminum, molybdenum, and selenium on the two instruments. The best analytical practice is to calibrate instruments using calibration standards prepared in matrices that reasonably match those of the samples being analyzed.Filtered and unfiltered samples were spiked over a range of trace-element concentrations from less than 1 to 58 times ambient concentrations. The greater the magnitude of the trace-element spike concentration relative to the ambient concentration, the greater the likelihood spike recoveries will be within data control guidelines (80–120 percent). Greater variability in spike recoveries occurred when trace elements were spiked at concentrations less than 10 times the ambient concentration. Spike recoveries that were considerably lower than 90 percent often were associated with spiked concentrations substantially lower than what was present in the ambient sample. Because the main purpose of spiking natural water samples with known quantities of a particular analyte is to assess possible matrix effects on analytical results, the results of this study stress the importance of spiking samples at concentrations that are reasonably close to what is expected but sufficiently high to exceed analytical variability. Generally, differences in spike recovery results between paired filtered and unfiltered samples were minimal when samples were analyzed on the same instrument.Analytical results for trace-element concentrations in ambient filtered and unfiltered samples greater than 10 and 40 μg/L, respectively, were within the data-quality objective for precision of ±25 percent. Ambient trace-element concentrations in filtered samples greater than the long-term method detection limits but less than 10 μg/L failed to meet the data-quality objective for precision for at least one trace element in about 54 percent of the samples. Similarly, trace-element concentrations in unfiltered samples greater than the long-term method detection limits but less than 40 μg/L failed to meet this data-quality objective for at least one trace-element analysis in about 58 percent of the samples. Although, aluminum and zinc were particularly problematic, limited re-analyses of filtered and unfiltered samples appeared to improve otherwise failed analytical precision.The evaluation of analytical bias using standard reference materials indicate a slight low bias for results for arsenic, cadmium, selenium, and zinc. Aluminum and molybdenum show signs of high bias. There was no observed bias, as determined using the standard reference materials, during the analysis of lead.

  11. [Instruments for evaluating oral health knowledge, attitudes and practice for parents /caregivers of small children].

    PubMed

    Martignon, Stefania; Bautista-Mendoza, Gloria; González-Carrera, María; Lafaurie-Villamil, Gloria; Morales, Veicy; Santamaría, Ruth

    2008-01-01

    Designing three instruments for evaluating oral health knowledge, attitudes and practice in parents/caregivers of low social-economic status 0-5 year-olds. Evaluating the instruments' reliability in terms of internal consistency and analysing items. Three instruments were constructed for evaluating low social-economic status 0-5 year-olds' parents/caregivers' oral health knowledge, attitudes and practice in the municipality of Usaquén , Bogotá , Colombia . 47 parents/caregivers were given a test establishing the instrument's reliability in terms of internal consistency and the adults' level of knowledge, attitudes and practice. A sub-sample was qualitatively analysed (content verification and understanding). Reliability was evaluated using Cronbach's alpha coefficient. Items were analysed for improving constructing and understanding the questions, taking four criteria into account: corrected homogeneity index (CHI), response trend, correlation between items and qualitative analysis. Cronbach's alpha coefficient for knowledge, attitudes and practice was 0,82, 0,80 and 0,62, respectively. Participants' level of knowledge, attitudes and practice was acceptable (60 %, 55 % and 91 %, respectively). This study found two out of the three evaluated instruments to be reliable (knowledge and attitudes); all three of them were then redesigned. The resulting instruments represent a valuable tool which can be used in future studies for describing and evaluating preventative programmes.

  12. Local density measurement of additive manufactured copper parts by instrumented indentation

    NASA Astrophysics Data System (ADS)

    Santo, Loredana; Quadrini, Fabrizio; Bellisario, Denise; Tedde, Giovanni Matteo; Zarcone, Mariano; Di Domenico, Gildo; D'Angelo, Pierpaolo; Corona, Diego

    2018-05-01

    Instrumented flat indentation has been used to evaluate local density of additive manufactured (AM) copper samples with different relative density. Indentations were made by using tungsten carbide (WC) flat pins with 1 mm diameter. Pure copper powders were used in a selective laser melting (SLM) machine to produce samples to test. By changing process parameters, samples density was changed from the relative density of 63% to 71%. Indentation tests were performed on the xy surface of the AM samples. In order to make a correlation between indentation test results and sample density, the indentation pressure at fixed displacement was selected. Results show that instrumented indentation is a valid technique to measure density distribution along the geometry of an SLM part. In fact, a linear trend between indentation pressure and sample density was found for the selected density range.

  13. [Security material for venous peripheral..catheterization evaluation in an emergency ward].

    PubMed

    Romero Ruiz, Adolfo; Jiménez Ruiz, Manuel; Rodríguez Navarro, Luis Miguel; Muñoz Pascual, José Carlos; Ramos Rueda, M del Carmen; Torres Pérez, Luis

    2007-06-01

    Venous canalization can be one of the most frequent causes of accidents due to an accidental puncture. To carry out activities which serve to lessen these misfortunes, bearing high biological risk, should become a priority for sanitary institutions and for their professionals. Inside a global strategy which deals with this aspect and with the objective of evaluating the convenience these instruments have in our center the authors made a practical evaluation on a series of them to discover their technical viability and their subjective consideration by professionals who employ them. For motives related to the practices of the ward in which this research took place, an emergency ward, the authors intentionally chose two passive instruments, available on the market, and three nurses who received 120 sample security catheters, 60 each for products A and B, to carry out habitual clinical practices, alongside a pad of paper on which to record any incidents. Regarding instrument A, 30 incidents, 52.6%, were detected while 37 sample procedures occurred. Regarding instrument B, 4 incidents, 7.01%, were detected while 47 sample procedures occurred. In absolute terms, neither of the two instruments demonstrated problems of an insecure manner; which is to say neither produced a situation related to the appearance of mis fortunate incidents associated to accidental punctures. The lower number of incidents with instrument B appears to be related to the habitual use of a conventional cathetec not a security one, produced by the same manufacturer in our center This research project was subsidized by the Sanitary Research Fund, PI 051265.

  14. 77 FR 2340 - Occupational Information Development Advisory Panel

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-17

    ... testing of an OIS content model and taxonomy, work analysis instrumentation, sampling, and data collection... economics, sampling, data collection and analyses; (b) disability evaluation, vocational rehabilitation...

  15. Test evaluation of potential heatshield contamination of an outer planet probe's gas sampling system

    NASA Technical Reports Server (NTRS)

    Kessler, W. C.

    1975-01-01

    The feasibility of retaining the heat shield for outer planet probes was investigated as a potential source of atmospheric sample contamination by outgassing. The onboard instruments which are affected by the concept are the pressure sensor, temperature sensor, IR detector, nephelometer, and gas sampling instruments. It was found that: (1) The retention of the charred heatshield and the baseline atmospheric sampling concepts are compatible with obtaining noncontaminated atmospheric samples. (2) Increasing the sampling tube length so that it extends beyond the viscous boundary layer eliminates contamination of the atmospheric sample. (3) The potential for contamination increases with angle of attack.

  16. Young Children's Perceptions of Teacher-Child Relationships: An Evaluation of Two Instruments and the Role of Child Gender in Kindergarten

    ERIC Educational Resources Information Center

    Spilt, Jantine L.; Koomen, Helma M. Y.; Mantzicopoulos, Panayota Y.

    2010-01-01

    The psychometric qualities of two instruments that measure children's perceptions of teacher-child relationships were evaluated in a sample of kindergartners (N = 150): The Young Children's Appraisals of Teacher Support (Y-CATS) and the Kindergartner-Teacher Interaction Computer (KLIC) test. On the Y-CATS, children judged propositions on a…

  17. Ground Training Devices in Job Sample Approach to UPT [Undergraduate Pilot Training] Selection and Screening. Final Report, September 1972-August 1974.

    ERIC Educational Resources Information Center

    LeMaster, W. Dean; Gray, Thomas H.

    The purpose of this study was to develop a screening procedure for undergraduate pilot training (UPT). This procedure was based upon the use of ground-based instrument trainers in which UPT candidates, naive to flying, were evaluated in their performance of job sample tasks; i.e., basic instrument flying. Training and testing sessions were…

  18. Evaluation of the late life disability instrument in the Lifestyle Interventions and Independence for Elders Pilot (LIFE-P) study

    USDA-ARS?s Scientific Manuscript database

    The late life disability instrument (LLDI) was developed to assess limitations in instrumental and management roles using a small and restricted sample. In this paper we examine the measurement properties of the LLDI using data from the Lifestyle Interventions and Independence for Elders Pilot (LIFE...

  19. Psychometric evaluation of a new instrument in Spanish to measure the wellness of university nursing faculty.

    PubMed

    Hurtado-Pardos, Barbara; Casas, Irma; Lluch-Canut, Teresa; Moreno-Arroyo, Carmen; Nebot-Bergua, Carlos; Roldán-Merino, Juan

    2018-01-02

    The aim of this study was to design and validate an instrument to measure the wellness among university nursing faculty. The study was performed in two phases. Phase I consisted of the development of the instrument with discussion groups and participant consensus. We designed an instrument including the 21 items or psychosocial risk factors identified and estimated an index by evaluating the frequency and intensity of each item. The items were grouped into 3 dimensions: teaching work demands, curricular demands, and organizational difficulties. Phase II, we evaluated the psychometric properties of the tool in a sample of 263 participants. Exploratory factor analysis showed a 3-factor structure that explained 53% of the total variance. The internal consistency of the instrument was 0.91 for the whole instrument. The results indicate that the tool developed is valid and reliable and may be a good instrument to monitor the wellness of university nursing faculty.

  20. Falsification Testing of Instrumental Variables Methods for Comparative Effectiveness Research.

    PubMed

    Pizer, Steven D

    2016-04-01

    To demonstrate how falsification tests can be used to evaluate instrumental variables methods applicable to a wide variety of comparative effectiveness research questions. Brief conceptual review of instrumental variables and falsification testing principles and techniques accompanied by an empirical application. Sample STATA code related to the empirical application is provided in the Appendix. Comparative long-term risks of sulfonylureas and thiazolidinediones for management of type 2 diabetes. Outcomes include mortality and hospitalization for an ambulatory care-sensitive condition. Prescribing pattern variations are used as instrumental variables. Falsification testing is an easily computed and powerful way to evaluate the validity of the key assumption underlying instrumental variables analysis. If falsification tests are used, instrumental variables techniques can help answer a multitude of important clinical questions. © Health Research and Educational Trust.

  1. The development and psychometrical evaluation of a set of instruments to evaluate the effectiveness of diabetes patient education.

    PubMed

    Duprez, Veerle; De Pover, Marleen; De Spiegelaere, Marc; Beeckman, Dimitri

    2014-02-01

    To develop a set of psychometrically sound instruments to assess knowledge, self-management and self-efficacy of diabetic patients. Furthermore, a survey to evaluate the satisfaction about diabetes education for patients was developed and tested. Treatment and secondary prevention of diabetes require a complex combination of care components. Patients' education has been accepted to improve diabetes knowledge, self-management and self-efficacy. Psychometrically sound instruments are needed to measure these patient-centred outcomes. Psychometric instrument validation. The first phase included a systematic literature review to develop the instruments. Content validity was evaluated using a two-round Delphi procedure involving diabetes experts. The content validity of the instruments was excellent. In a second phase, a convenience sample of 188 diabetic patients in two hospitals in one specific care region in Belgium participated in the psychometric evaluation. The criterion-related validity and internal consistency reliability were evaluated. The study produced a 21-item knowledge instrument, reflecting knowledge about 'glycemic control' and 'medico-social management aspects'. The self-management instrument included 32 statements, reflecting 'treatment and compliance' and 'general lifestyle'. The self-efficacy instrument included 30 items, reflecting 'nutrition', 'treatment' and 'regimen'. The patient satisfaction survey included 36 items, reflecting satisfaction about the relationship among the diabetes specialist, the diabetes educator, podiatrist and dietician. An instrument set with sound psychometric characteristics was developed to assess knowledge, self-management and self-efficacy of diabetic patients. Future studies should focus on the association between the instrument outcomes and clinical patient outcomes. The current instrument can support the design of educational interventions and training programmes and reduce inconsistencies in the information that patients receive. Furthermore, the instruments can be used for benchmarking the quality of diabetic patient education. © 2013 Blackwell Publishing Ltd.

  2. Cultural adaptation and psychometric properties of the family questionnaire in a Brazilian sample of relatives of schizophrenia outpatients.

    PubMed

    Zanetti, Ana C G; Wiedemann, Georg; Dantas, Rosana A S; Hayashida, Miyeko; de Azevedo-Marques, João M; Galera, Sueli A F

    2013-06-01

    To evaluate the internal reliability and validity of the Brazilian Portuguese version of the Family Questionnaire among families of schizophrenia outpatients. The main studies about the family environment of schizophrenia patients are related to the concept of Expressed Emotion. There is currently no instrument to evaluate this concept in Brazil that is easily applicable and comparable with studies from other countries. Methodological and cross-sectional research design. A convenience sample of 130 relatives of schizophrenia outpatients was selected. The translation and cultural adaptation of the instrument involved experts in mental health and experts in the German language and included back translation, semantic evaluation of items and pretesting of the instrument with 30 relatives of schizophrenia outpatients. The psychometric properties of the instrument were studied with another 100 relatives, which fulfilled the requirements for the Brazilian Portuguese version of the instrument. The psychometric properties of the instrument were assessed by construct validity (using an analysis of its key components, comparisons between distinct groups-convergent validity with the Antonovsky's Sense of Coherence Scale) and reliability (checking the internal consistency of its items and its test-retest reproducibility). The analysis of main components confirmed dimensionality patterns that were comparable between the original and adapted versions. In two domains of the instrument, critical comments and emotional over-involvement had moderate and significant correlations, respectively, with Antonovsky's Sense of Coherence Scale, appropriate values of Cronbach's alpha and strong and significant correlations, respectively, in test-retest reproducibility. We observed significant differences between distinct groups of parents in the category of emotional over-involvement. We conclude that the Portuguese-adapted version of the Family Questionnaire is valid and reliable for the study sample. This study provided evidence that the Family Questionnaire is a reliable and valid instrument for assessing expressed emotion. It is easy and practical to use and is acceptable for use in a Brazilian cultural population. © 2012 Blackwell Publishing Ltd.

  3. TOPLEX: Teleoperated Lunar Explorer. Instruments and Operational Concepts for an Unmanned Lunar Rover

    NASA Technical Reports Server (NTRS)

    Blacic, James D.

    1992-01-01

    A Teleoperated Lunar Explorer, or TOPLEX, consisting of a lunar lander payload in which a small, instrument-carrying lunar surface rover is robotically landed and teleoperated from Earth to perform extended lunar geoscience and resource evaluation traverses is proposed. The rover vehicle would mass about 100 kg and carry approximately 100 kg of analytic instruments. Four instruments are envisioned: (1) a Laser-Induced Breakdown Spectrometer (LIBS) for geochemical analysis at ranges up to 100 m, capable of operating in three different modes; (2) a combined x-ray fluorescence and x-ray diffraction (XRF/XRD) instrument for elemental and mineralogic analysis of acquired samples; (3) a mass spectrometer system for stepwise heating analysis of gases released from acquired samples; and (4) a geophysical instrument package for subsurface mapping of structures such as lava tubes.

  4. Socially supportive activity inventory: reliability and validity of a social activity instrument for long-term care institutions.

    PubMed

    Hsu, Ya-Chuan

    2011-09-01

    : Diverse social and recreational activities in elder care institutions have been provided to enrich a person's mental well-being amidst what is a relatively monotonous life. However, few instruments that measure the social activities of long-term care residents are available. : This study was designed to develop a culturally sensitive instrument (Socially Supportive Activity Inventory, SSAI) to assess quantity and quality of social activities for long-term care institutions and validate the instrument's psychometric properties. : The SSAI was developed on the basis of the social support theory, a synthesis of literature, and Taiwanese cultural mores. The instrument was rigorously subjected to a two-stage process to evaluate its reliability and validity. In Stage 1, six experts from diverse backgrounds were recruited to evaluate instrument items and estimate the content validity of the instrument using a content validity questionnaire. Items were modified and refined on the basis of the responses of the expert panel and a set of criteria. After obtaining approval from a university institutional review board, in the second stage of evaluating test-retest reliability, a convenience sample of 10 Taiwanese institutionalized elders in a pilot study, recruited from a nursing home, completed the revised instrument at two separate times over 2 weeks. : Results showed a content validity of .96. Test-retest reliability from a sample of 10 participants yielded stability coefficients of .76-1.00. The stability coefficient was 1.00 for the component of frequency, .76-1.00 for the component of meaningfulness, and .78-1.00 for the component of enjoyment. : The SSAI is a highly relevant and reliable culturally based instrument that can measure social activity in long-term care facilities. Because of the pilot nature of this study, future directions include further exploration of the SSAI instrument's psychometric properties. This should be done by enlarging the sample size to include more long-term care facilities and individual participants. Future studies can utilize diverse measures of social activity for comparison and validation of the SSAI.

  5. Psychometric Evaluation of a New Instrument to Evaluate School Nurses' Perceptions on Concussion Care Management.

    PubMed

    Schneider, Kathleen H

    2017-10-01

    The rate of concussions in adolescents has risen over the last decade, resulting in cognitive and emotional problems. Neurologists recommend cognitive and physical rest during the recovery period, followed by a transitional return-to-classroom protocol. The purpose of the study was to develop and test an instrument that explores the beliefs and roles of school nurses in concussion care management. The instrument was a cross-sectional descriptive survey based on the theory of planned behavior, using Qualtrics®. The psychometric properties of the instrument were assessed through exploratory factor analysis with orthogonal rotation. The reliability of the instrument was assessed for internal consistency reliability using Cronbach's α. Kaiser-Meyer-Olkin for sample adequacy was .8; Cronbach's α strong (.851).

  6. Measures of Wellness in Young Adult College Students: An Integrative Review.

    PubMed

    Nair, Julie McCulloh

    2018-04-01

    Wellness behaviors typically form during the college years, making wellness evaluation crucial during this time frame. Instruments often assess health rather than wellness. Thus, the purpose of this integrative review is to identify and evaluate instruments measuring wellness among young adult college students. Google Scholar, CINAHL, PubMed, MEDLINE, PsycINFO, ERIC, and other databases were searched yielding 350 studies initially. Seven studies met inclusion criteria and were retained for this review. Reliability and validity is reported in each study with ongoing analysis. Homogeneous samples were reported in each study, and administering concurrent instruments created feasibility issues. A summary of instruments measuring wellness in young adult college students is provided. However, few wellness instruments exist in this population. Thus, further development is needed.

  7. Validity and reliability of Patient-Reported Outcomes Measurement Information System (PROMIS) Instruments in Osteoarthritis

    PubMed Central

    Broderick, Joan E.; Schneider, Stefan; Junghaenel, Doerte U.; Schwartz, Joseph E.; Stone, Arthur A.

    2013-01-01

    Objective Evaluation of known group validity, ecological validity, and test-retest reliability of four domain instruments from the Patient Reported Outcomes Measurement System (PROMIS) in osteoarthritis (OA) patients. Methods Recruitment of an osteoarthritis sample and a comparison general population (GP) through an Internet survey panel. Pain intensity, pain interference, physical functioning, and fatigue were assessed for 4 consecutive weeks with PROMIS short forms on a daily basis and compared with same-domain Computer Adaptive Test (CAT) instruments that use a 7-day recall. Known group validity (comparison of OA and GP), ecological validity (comparison of aggregated daily measures with CATs), and test-retest reliability were evaluated. Results The recruited samples matched (age, sex, race, ethnicity) the demographic characteristics of the U.S. sample for arthritis and the 2009 Census for the GP. Compliance with repeated measurements was excellent: > 95%. Known group validity for CATs was demonstrated with large effect sizes (pain intensity: 1.42, pain interference: 1.25, and fatigue: .85). Ecological validity was also established through high correlations between aggregated daily measures and weekly CATs (≥ .86). Test-retest validity (7-day) was very good (≥ .80). Conclusion PROMIS CAT instruments demonstrated known group and ecological validity in a comparison of osteoarthritis patients with a general population sample. Adequate test-retest reliability was also observed. These data provide encouraging initial data on the utility of these PROMIS instruments for clinical and research outcomes in osteoarthritis patients. PMID:23592494

  8. QC-ART: A tool for real-time quality control assessment of mass spectrometry-based proteomics data.

    PubMed

    Stanfill, Bryan A; Nakayasu, Ernesto S; Bramer, Lisa M; Thompson, Allison M; Ansong, Charles K; Clauss, Therese; Gritsenko, Marina A; Monroe, Matthew E; Moore, Ronald J; Orton, Daniel J; Piehowski, Paul D; Schepmoes, Athena A; Smith, Richard D; Webb-Robertson, Bobbie-Jo; Metz, Thomas O

    2018-04-17

    Liquid chromatography-mass spectrometry (LC-MS)-based proteomics studies of large sample cohorts can easily require from months to years to complete. Acquiring consistent, high-quality data in such large-scale studies is challenging because of normal variations in instrumentation performance over time, as well as artifacts introduced by the samples themselves, such as those due to collection, storage and processing. Existing quality control methods for proteomics data primarily focus on post-hoc analysis to remove low-quality data that would degrade downstream statistics; they are not designed to evaluate the data in near real-time, which would allow for interventions as soon as deviations in data quality are detected.  In addition to flagging analyses that demonstrate outlier behavior, evaluating how the data structure changes over time can aide in understanding typical instrument performance or identify issues such as a degradation in data quality due to the need for instrument cleaning and/or re-calibration.  To address this gap for proteomics, we developed Quality Control Analysis in Real-Time (QC-ART), a tool for evaluating data as they are acquired in order to dynamically flag potential issues with instrument performance or sample quality.  QC-ART has similar accuracy as standard post-hoc analysis methods with the additional benefit of real-time analysis.  We demonstrate the utility and performance of QC-ART in identifying deviations in data quality due to both instrument and sample issues in near real-time for LC-MS-based plasma proteomics analyses of a sample subset of The Environmental Determinants of Diabetes in the Young cohort. We also present a case where QC-ART facilitated the identification of oxidative modifications, which are often underappreciated in proteomic experiments. Published under license by The American Society for Biochemistry and Molecular Biology, Inc.

  9. Measuring stakeholder participation in evaluation: an empirical validation of the Participatory Evaluation Measurement Instrument (PEMI).

    PubMed

    Daigneault, Pierre-Marc; Jacob, Steve; Tremblay, Joël

    2012-08-01

    Stakeholder participation is an important trend in the field of program evaluation. Although a few measurement instruments have been proposed, they either have not been empirically validated or do not cover the full content of the concept. This study consists of a first empirical validation of a measurement instrument that fully covers the content of participation, namely the Participatory Evaluation Measurement Instrument (PEMI). It specifically examines (1) the intercoder reliability of scores derived by two research assistants on published evaluation cases; (2) the convergence between the scores of coders and those of key respondents (i.e., authors); and (3) the convergence between the authors' scores on the PEMI and the Evaluation Involvement Scale (EIS). A purposive sample of 40 cases drawn from the evaluation literature was used to assess reliability. One author per case in this sample was then invited to participate in a survey; 25 fully usable questionnaires were received. Stakeholder participation was measured on nominal and ordinal scales. Cohen's κ, the intraclass correlation coefficient, and Spearman's ρ were used to assess reliability and convergence. Reliability results ranged from fair to excellent. Convergence between coders' and authors' scores ranged from poor to good. Scores derived from the PEMI and the EIS were moderately associated. Evidence from this study is strong in the case of intercoder reliability and ranges from weak to strong in the case of convergent validation. Globally, this suggests that the PEMI can produce scores that are both reliable and valid.

  10. Evaluation and Comparison of Methods for Measuring Ozone ...

    EPA Pesticide Factsheets

    Ambient evaluations of the various ozone and NO2 methods were conducted during field intensive studies as part of the NASA DISCOVER-AQ project conducted during July 2011 near Baltimore, MD; January – February 2013 in the San Juaquin valley, CA; September 2013 in Houston, TX; and July – August 2014 near Denver, CO. During field intensive studies, instruments were calibrated according to manufacturers’ operation manuals and in accordance with FRM requirements listed in 40 CFR 50. During the ambient evaluation campaigns, nightly automated zero and span checks were performed to monitor the validity of the calibration and control for drifts or variations in the span and/or zero response. Both the calibration gas concentrations and the nightly zero and span gas concentrations were delivered using a dynamic dilution calibration system (T700U/T701H, Teledyne API). The analyzers were housed within a temperature-controlled shelter during the sampling campaigns. A glass inlet with sampling height located approximately 5 m above ground level and a subsequent sampling manifold were shared by all instruments. Data generated by all analyzers were collected and logged using a field deployable data acquisition system (Envidas Ultimate). A summary of instruments used during DISCOVER-AQ deployment are listed in Table 1. Figure 1 shows a typical DISCOVER-AQ site (Houston 2013) where EPA (and others) instrumentation was deployed. Under the Clean Air Act, the U.S. EPA has estab

  11. LIMS for Lasers 2015 for achieving long-term accuracy and precision of δ2H, δ17O, and δ18O of waters using laser absorption spectrometry

    USGS Publications Warehouse

    Coplen, Tyler B.; Wassenaar, Leonard I

    2015-01-01

    RationaleAlthough laser absorption spectrometry (LAS) instrumentation is easy to use, its incorporation into laboratory operations is not easy, owing to extensive offline manipulation of comma-separated-values files for outlier detection, between-sample memory correction, nonlinearity (δ-variation with water amount) correction, drift correction, normalization to VSMOW-SLAP scales, and difficulty in performing long-term QA/QC audits.MethodsA Microsoft Access relational-database application, LIMS (Laboratory Information Management System) for Lasers 2015, was developed. It automates LAS data corrections and manages clients, projects, samples, instrument-sample lists, and triple-isotope (δ17O, δ18O, and δ2H values) instrumental data for liquid-water samples. It enables users to (1) graphically evaluate sample injections for variable water yields and high isotope-delta variance; (2) correct for between-sample carryover, instrumental drift, and δ nonlinearity; and (3) normalize final results to VSMOW-SLAP scales.ResultsCost-free LIMS for Lasers 2015 enables users to obtain improved δ17O, δ18O, and δ2H values with liquid-water LAS instruments, even those with under-performing syringes. For example, LAS δ2HVSMOW measurements of USGS50 Lake Kyoga (Uganda) water using an under-performing syringe having ±10 % variation in water concentration gave +31.7 ± 1.6 ‰ (2-σ standard deviation), compared with the reference value of +32.8 ± 0.4 ‰, after correction for variation in δ value with water concentration, between-sample memory, and normalization to the VSMOW-SLAP scale.ConclusionsLIMS for Lasers 2015 enables users to create systematic, well-founded instrument templates, import δ2H, δ17O, and δ18O results, evaluate performance with automatic graphical plots, correct for δ nonlinearity due to variable water concentration, correct for between-sample memory, adjust for drift, perform VSMOW-SLAP normalization, and perform long-term QA/QC audits easily. Published in 2015. This article is a U.S. Government work and is in the public domain in the USA.

  12. A mineralogical instrument for planetary applications

    NASA Technical Reports Server (NTRS)

    Blake, David F.; Vaniman, David T.; Bish, David L.

    1994-01-01

    The mineralogy of a planetary surface can be used to identify the provenance of soil or sediment and reveal the volcanic, metamorphic and/or sedimentological history of a particular region. We have discussed elsewhere the applications and the instrument design of possible X-ray diffraction and X-ray fluorescence (XRD/XRF) devices for the mineralogical characterization of planetary surfaces. In this abstract we evaluate some aspects of sample-detector geometry and sample collection strategies.

  13. Analytical evaluation of the automated galectin-3 assay on the Abbott ARCHITECT immunoassay instruments.

    PubMed

    Gaze, David C; Prante, Christian; Dreier, Jens; Knabbe, Cornelius; Collet, Corinne; Launay, Jean-Marie; Franekova, Janka; Jabor, Antonin; Lennartz, Lieselotte; Shih, Jessie; del Rey, Jose Manuel; Zaninotto, Martina; Plebani, Mario; Collinson, Paul O

    2014-06-01

    Galectin-3 is secreted from macrophages and binds and activates fibroblasts forming collagen. Tissue fibrosis is central to the progression of chronic heart failure (CHF). We performed a European multicentered evaluation of the analytical performance of the two-step routine and Short Turn-Around-Time (STAT) galectin-3 immunoassay on the ARCHITECT i1000SR, i2000SR, and i4000SR (Abbott Laboratories). We evaluated the assay precision and dilution linearity for both routine and STAT assays and compared serum and plasma, and fresh vs. frozen samples. The reference interval and biological variability were also assessed. Measurable samples were compared between ARCHITECT instruments and between the routine and STAT assays and also to a galectin-3 ELISA (BG Medicine). The total assay coefficient of variation (CV%) was 2.3%-6.2% and 1.7%-7.4% for the routine and STAT assays, respectively. Both assays demonstrated linearity up to 120 ng/mL. Galectin-3 concentrations were higher in plasma samples than in serum samples and correlated well between fresh and frozen samples (R=0.997), between the routine and STAT assays, between the ARCHITECT i1000 and i2000 instruments and with the galectin-3 ELISA. The reference interval on 627 apparently healthy individuals (53% male) yielded upper 95th and 97.5th percentiles of 25.2 and 28.4 ng/mL, respectively. Values were significantly lower in subjects younger than 50 years. The galectin-3 routine and STAT assays on the Abbott ARCHITECT instruments demonstrated good analytical performance. Further clinical studies are required to demonstrate the diagnostic and prognostic potential of this novel marker in patients with CHF.

  14. Evaluation of a New Handheld Instrument for the Detection of Counterfeit Artesunate by Visual Fluorescence Comparison

    PubMed Central

    Ranieri, Nicola; Tabernero, Patricia; Green, Michael D.; Verbois, Leigh; Herrington, James; Sampson, Eric; Satzger, R. Duane; Phonlavong, Chindaphone; Thao, Khamxay; Newton, Paul N.; Witkowski, Mark R.

    2014-01-01

    There is an urgent need for accurate and inexpensive handheld instruments for the evaluation of medicine quality in the field. A blinded evaluation of the diagnostic accuracy of the Counterfeit Detection Device 3 (CD-3), developed by the US Food and Drug Administration Forensic Chemistry Center, was conducted in the Lao People's Democratic Republic. Two hundred three samples of the oral antimalarial artesunate were compared with authentic products using the CD-3 by a trainer and two trainees. The specificity (95% confidence interval [95% CI]), sensitivity (95% CI), positive predictive value (95% CI), and negative predictive value (95% CI) of the CD-3 for detecting counterfeit (falsified) artesunate were 100% (93.8–100%), 98.4% (93.8–99.7%), 100% (96.2–100%), and 97.4% (90.2–99.6%), respectively. Interobserver agreement for 203 samples of artesunate was 100%. The CD-3 holds promise as a relatively inexpensive and easy to use instrument for field evaluation of medicines, potentially empowering drug inspectors, customs agents, and pharmacists. PMID:25266348

  15. Professionalism Mini-Evaluation Exercise in Finland: A preliminary investigation introducing the Finnish version of the P-MEX instrument.

    PubMed

    Karukivi, Max; Kortekangas-Savolainen, Outi; Saxén, Ulla; Haapasalo-Pesu, Kirsi-Maria

    2015-10-01

    Teaching medical professionalism is increasingly acknowledged as an important aspect of medical education. The Professionalism Mini-Evaluation Exercise (P-MEX) is an assessment tool for evaluating medical professionalism, but no studies using it as a self-assessment instrument have been reported. This paper reports on a preliminary investigation of the Finnish version of the P-MEX instrument as an assessment and self-assessment measure. The sample in the present cross-sectional study comprised all 23 medical students and recent graduates (15 females and 8 males) participating in a summer school of psychiatry program in 2014. The two-month program combines clinical work with multifaceted teaching and intensive tutoring. At the end of the program, the participants' medical professionalism was assessed by the tutors and other members of the work community as well as the students themselves using the Finnish version of the P-MEX instrument. The P-MEX scores were compared, using the Friedman test. The mean values and SD for the P-MEX assessments were as follows: tutor assessment 3.26±0.21, work community assessment 3.32±0.26 and self-assessment 3.01±0.07. No significant gender differences were observed. The tutor and work community assessments were significantly correlated (r=0.573, p=0.040), but the self-assessment scores did not correlate with either of the other assessments. Overall, the students evaluated their skills significantly poorer in comparison to the other assessments. Although the small sample size limits the generalization of these preliminary results, the Finnish version of the P-MEX instrument appears to be a feasible measure of medical professionalism. The instrument can also be used as a self-assessment instrument, but subjective evaluations should be complemented with external assessments or feedback in order to take individual and cultural aspects into account.

  16. The development and psychometric validation of an instrument to evaluate nurses' attitudes towards communication with the patient (ACO).

    PubMed

    Giménez-Espert, María Del Carmen; Prado-Gascó, Vicente Javier

    2018-05-01

    Patient communication is a key skill for nurses involved in clinical care. Its measurement is a complex phenomenon that can be addressed through attitude evaluation. To develop and psychometrically test a measure of nurses' attitudes towards communication with patients (ACO), to study the relationship between these dimensions, and to analyse nursing attitudes. To develop and psychometrically test the ACO questionnaire. All hospitals in the province of Valencia were invited by e-mail to distribute the ACO instrument. Ten hospitals took part in the study. The study population was composed of a convenience sample of 400 hospital nurses on general or special services. The inclusion criteria were nurses at the selected centres who had previously provided an informed consent to participate. A literature review and expert consultation (N = 10) was used to develop the content of the questionnaire. The 62-item version of the instrument was applied to a convenience sample of 400 nurses between May 2015 and March 2016. Factor structure was evaluated with exploratory and confirmatory factor analysis (EFA, CFA), and reliability was evaluated with Cronbach's alpha, composite reliability (CR), and average variance extracted (AVE). The final instrument (ACO), composed of 25 items grouped into three attitude dimensions (cognitive, affective and behavioural), had good psychometric properties. In the study sample, nurses had a favourable attitude towards communication. The cognitive and affective dimensions of the ACO should be able to predict the behaviour dimension. The ACO is useful for evaluating current clinical practices, identifying educational needs and assessing the effectiveness of communication training or other interventions intended to improve communication. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. A Performance Appraisal System for School Principals.

    ERIC Educational Resources Information Center

    Knoop, Robert; Common, Ronald W.

    The Performance Review, Analysis, and Improvement System for Educators (PRAISE) is a formative evaluation instrument designed to improve the performance of school principals. The system appears to be reliable and valid and is flexible enough to accommodate the needs of a variety of schools. Sample items and categories of the instrument include…

  18. The Early Development Instrument: An Examination of Convergent and Discriminant Validity

    ERIC Educational Resources Information Center

    Hymel, Shelley; LeMare, Lucy; McKee, William

    2011-01-01

    The convergent and discriminant validity of the Early Development Instrument (EDI), a teacher-rated assessment of children's "school readiness", was investigated in a multicultural sample of 267 kindergarteners (53% male). Teachers evaluations on the EDI, both overall and in five domains (physical health/well-being, social competence,…

  19. EVALUATION OF RAPID DNA EXTRACTION PROCEDURES FOR THE QUANTITATIVE DETECTION OF FUNGAL CELLS USING REAL TIME PCR ANALYSIS

    EPA Science Inventory

    The ease and rapidity of quantitative DNA sequence detection by real-time PCR instruments promises to make their use increasingly common for the microbial analysis many different types of environmental samples. To fully exploit the capabilities of these instruments, correspondin...

  20. Issues in the Evaluation of Educational Television Programs

    ERIC Educational Resources Information Center

    Aversa, Frances M.; Forman, David C.

    1978-01-01

    Seven issues raised during an evaluation study of televised instructional components are identified: selection and commitment of sample, environment of evaluation sessions, student and expert review, formulation of an explicit evaluation model, conflicting results from different instruments, standards and the interpretation of data, and style and…

  1. Instrumental neutron activation analysis data for cloud-water particulate samples, Mount Bamboo, Taiwan

    USGS Publications Warehouse

    Lin, Neng-Huei; Sheu, Guey-Rong; Wetherbee, Gregory A.; Debey, Timothy M.

    2013-01-01

    Cloud water was sampled on Mount Bamboo in northern Taiwan during March 22-24, 2002. Cloud-water samples were filtered using 0.45-micron filters to remove particulate material from the water samples. Filtered particulates were analyzed by instrumental neutron activation analysis (INAA) at the U.S. Geological Survey National Reactor Facility in Denver, Colorado, in February 2012. INAA elemental composition data for the particulate materials are presented. These data complement analyses of the aqueous portion of the cloud-water samples, which were performed earlier by the Department of Atmospheric Sciences, National Central University, Taiwan. The data are intended for evaluation of atmospheric transport processes and air-pollution sources in Southeast Asia.

  2. Adaptation and validation of the Spanish version of the Dieting Peer Competitiveness Scale to adolescents of both genders.

    PubMed

    Pamies-Aubalat, Lidia; Quiles-Marcos, Yolanda; Núñez-Núñez, Rosa M

    2013-12-01

    This study examined the Dieting Peer Competitiveness Scale; it is an instrument for evaluating this social comparison in young people. This instrumental study has two aims: The objective of the first aim was to present preliminary psychometric data from the Spanish version of the Dieting Peer Competitiveness Scale, including statistical item analysis, research about this instrument's internal structure, and a reliability analysis, from a sample of 1067 secondary school adolescents. The second objective of the study corresponds to confirmatory factor analysis of the scale's internal structure, as well as analysis for evidence of validity from a sample of 1075 adolescents.

  3. Expanding the enablement framework and testing an evaluative instrument for diabetes patient education.

    PubMed

    Leeseberg Stamler, L; Cole, M M; Patrick, L J

    2001-08-01

    Strategies to delay or prevent complications from diabetes include diabetes patient education. Diabetes educators seek to provide education that meets the needs of clients and influences positive health outcomes. (1) To expand prior research exploring an enablement framework for patient education by examining perceptions of patient education by persons with diabetes and (2) to test the mastery of stress instrument (MSI) as a potential evaluative instrument for patient education. Triangulated data collection with a convenience sample of adults taking diabetes education classes. Half the sample completed audio-taped semi-structured interviews pre, during and posteducation and all completed the MSI posteducation. Qualitative data were analysed using latent content analysis, descriptive statistics were completed. Qualitative analysis revealed content categories similar to previous work with prenatal participants, supporting the enablement framework. Statistical analyses noted congruence with psychometric findings from development of MSI; secondary qualitative analyses revealed congruency between MSI scores and patient perceptions. Mastery is an outcome congruent with the enablement framework for patient education across content areas. Mastery of stress instrument may be a instrument for identification of patients who are coping well with diabetes self-management, as well as those who are not and who require further nursing interventions.

  4. The Meal Pattern Questionnaire: A psychometric evaluation using the Eating Disorder Examination.

    PubMed

    Alfonsson, S; Sewall, A; Lidholm, H; Hursti, T

    2016-04-01

    Meal pattern is an important variable in both obesity treatment and treatment for eating disorders. Momentary assessment and eating diaries are highly valid measurement methods but often cumbersome and not always feasible to use in clinical practice. The aim of this study was to design and evaluate a self-report instrument for measuring meal patterns. The Pattern of eating item from the Eating Disorder Examination (EDE) interview was adapted to self-report format to follow the same overall structure as the Eating Disorder Examination Questionnaire. The new instrument was named the Meal Patterns Questionnaire (MPQ) and was compared with the EDE in a student sample (n=105) and an obese sample (n=111). The individual items of the MPQ and the EDE showed moderate to high correlations (rho=.63-89) in the two samples. Significant differences between the MPQ and EDE were only found for two items in the obese sample. The total scores correlated to a high degree (rho=.87/.74) in both samples and no significant differences were found in this variable. The MPQ can provide an overall picture of a person's eating patterns and is a valid way to collect data regarding meal patterns. The MPQ may be a useable tool in clinical practice and research studies when more extensive instruments cannot be used. Future studies should evaluate the MPQ in diverse cultural populations and with more ecological assessment methods. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Probing the Allende meteorite with a miniature laser-ablation mass analyser for space application

    NASA Astrophysics Data System (ADS)

    Neuland, M. B.; Meyer, S.; Mezger, K.; Riedo, A.; Tulej, M.; Wurz, P.

    2014-10-01

    We measured the elemental composition on a sample of Allende meteorite with a miniature laser ablation mass spectrometer. This laser mass spectrometer (LMS) has been designed and built at the University of Bern in the Department of Space Research and Planetary Sciences with the objective of using such an instrument on a space mission. Utilising the meteorite Allende as the test sample in this study, it is demonstrated that the instrument allows the in situ determination of the elemental composition and thus mineralogy and petrology of untreated rocky samples, particularly on planetary surfaces. In total, 138 measurements of elemental compositions have been carried out on an Allende sample. The mass spectrometric data are evaluated and correlated with an optical image. It is demonstrated that by illustrating the measured elements in the form of mineralogical maps, LMS can serve as an element imaging instrument with a very high spatial resolution of μm scale. The detailed analysis also includes a mineralogical evaluation and an investigation of the volatile element content of Allende. All findings are in good agreement with published data and underline the high sensitivity, accuracy and capability of LMS as a mass analyser for space exploration.

  6. Integrated fiducial sample mount and software for correlated microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Timothy R McJunkin; Jill R. Scott; Tammy L. Trowbridge

    2014-02-01

    A novel design sample mount with integrated fiducials and software for assisting operators in easily and efficiently locating points of interest established in previous analytical sessions is described. The sample holder and software were evaluated with experiments to demonstrate the utility and ease of finding the same points of interest in two different microscopy instruments. Also, numerical analysis of expected errors in determining the same position with errors unbiased by a human operator was performed. Based on the results, issues related to acquiring reproducibility and best practices for using the sample mount and software were identified. Overall, the sample mountmore » methodology allows data to be efficiently and easily collected on different instruments for the same sample location.« less

  7. A proposal for evaluating cognition in assertiveness.

    PubMed

    Vagos, Paula; Pereira, Anabela

    2010-09-01

    This article presents the development process and initial psychometric features of an instrument for evaluating cognition in assertiveness. This is an essential social skill for adolescent development and seems to encompass emotional, behavioral, and cognitive aspects. The instrument was created by combining both empirical and theoretical methods for item construction, aiming to evaluate the cognitive realm of assertiveness. A sample of 996 adolescent students was used to test for reliability and validity. Results indicate good psychometric properties. The instrument is composed of 4 subscales: Outer Emotional Support, Functional Personal Ability, Interpersonal Management, and Affective Personal Ability. The Assertive Interpersonal Schema Questionnaire may potentially be a useful tool in the diagnosis of, understanding of, and development of a treatment plan for individuals with persistent difficulties in social events.

  8. Computer graphics for quality control in the INAA of geological samples

    USGS Publications Warehouse

    Grossman, J.N.; Baedecker, P.A.

    1987-01-01

    A data reduction system for the routine instrumental activation analysis of samples is described, with particular emphasis on interactive graphics capabilities for evaluating analytical quality. Graphics procedures have been developed to interactively control the analysis of selected photopeaks during spectral analysis, and to evaluate detector performance during a given counting cycle. Graphics algorithms are also used to compare the data on reference samples with accepted values, to prepare quality control charts to evaluate long term precision and to search for systematic variations in data on reference samples as a function of time. ?? 1987 Akade??miai Kiado??.

  9. Reliability and Validity of the Turkish Version of the Job Performance Scale Instrument.

    PubMed

    Harmanci Seren, Arzu Kader; Tuna, Rujnan; Eskin Bacaksiz, Feride

    2018-02-01

    Objective measurement of the job performance of nursing staff using valid and reliable instruments is important in the evaluation of healthcare quality. A current, valid, and reliable instrument that specifically measures the performance of nurses is required for this purpose. The aim of this study was to determine the validity and reliability of the Turkish version of the Job Performance Instrument. This study used a methodological design and a sample of 240 nurses working at different units in four hospitals in Istanbul, Turkey. A descriptive data form, the Job Performance Scale, and the Employee Performance Scale were used to collect data. Data were analyzed using IBM SPSS Statistics Version 21.0 and LISREL Version 8.51. On the basis of the data analysis, the instrument was revised. Some items were deleted, and subscales were combined. The Turkish version of the Job Performance Instrument was determined to be valid and reliable to measure the performance of nurses. The instrument is suitable for evaluating current nursing roles.

  10. Analysis of HbA1c on an automated multicapillary zone electrophoresis system.

    PubMed

    Rollborn, Niclas; Åkerfeldt, Torbjörn; Nordin, Gunnar; Xu, Xiao Yan; Mandic-Havelka, Aleksandra; Hansson, Lars-Olof; Larsson, Anders

    2017-02-01

    Hemoglobin A1c (HbA1c) is a frequently requested laboratory test and there is thus a need for high throughput instruments for this assay. We evaluated a new automated multicapillary zone electrophoresis instrument (Capillarys 3 Tera, Sebia, Lisses, France) for analysis of HbA1c in venous samples. Routine requested HbA1c samples were analyzed immunologically on a Roche c6000 instrument (n = 142) and then with the Capillarys 3 Tera instrument. The Capillarys 3 Tera instrument performed approximately 70 HbA1c tests/hour. There was a strong linear correlation between Capillarys 3 Tera and Roche Tina-Quant HbA1c Gen 3 assay (y = 1.003x - 0.3246 R 2  = .996). The total CV for the 12 capillaries varied between 0.8 and 2.2% and there was a good agreement between duplicate samples (R 2  = .997). In conclusion, the Capillarys 3 Tera instrument has a high assay capacity for HbA1c. It has a good precision and agreement with the Roche Tina-Quant HbA1c method and is well suited for high volume testing of HbA1c.

  11. How to improve a critical performance for an ExoMars 2020 Scientific Instrument (RLS). Raman Laser Spectrometer Signal to Noise Ratio (SNR) Optimization

    NASA Astrophysics Data System (ADS)

    Canora, C. P.; Moral, A. G.; Rull, F.; Maurice, S.; Hutchinson, I.; Ramos, G.; López-Reyes, G.; Belenguer, T.; Canchal, R.; Prieto, J. A. R.; Rodriguez, P.; Santamaria, P.; Berrocal, A.; Colombo, M.; Gallago, P.; Seoane, L.; Quintana, C.; Ibarmia, S.; Zafra, J.; Saiz, J.; Santiago, A.; Marin, A.; Gordillo, C.; Escribano, D.; Sanz-Palominoa, M.

    2017-09-01

    The Raman Laser Spectrometer (RLS) is one of the Pasteur Payload instruments, within the ESA's Aurora Exploration Programme, ExoMars mission. Raman spectroscopy is based on the analysis of spectral fingerprints due to the inelastic scattering of light when interacting with matter. RLS is composed by Units: SPU (Spectrometer Unit), iOH (Internal Optical Head), and ICEU (Instrument Control and Excitation Unit) and the harnesses (EH and OH). The iOH focuses the excitation laser on the samples and collects the Raman emission from the sample via SPU (CCD) and the video data (analog) is received, digitalizing it and transmiting it to the processor module (ICEU). The main sources of noise arise from the sample, the background, and the instrument (Laser, CCD, focuss, acquisition parameters, operation control). In this last case the sources are mainly perturbations from the optics, dark signal and readout noise. Also flicker noise arising from laser emission fluctuations can be considered as instrument noise. In order to evaluate the SNR of a Raman instrument in a practical manner it is useful to perform end-to-end measurements on given standards samples. These measurements have to be compared with radiometric simulations using Raman efficiency values from literature and taking into account the different instrumental contributions to the SNR. The RLS EQM instrument performances results and its functionalities have been demonstrated in accordance with the science expectations. The Instrument obtained SNR performances in the RLS EQM will be compared experimentally and via analysis, with the Instrument Radiometric Model tool. The characterization process for SNR optimization is still on going. The operational parameters and RLS algorithms (fluorescence removal and acquisition parameters estimation) will be improved in future models (EQM-2) until FM Model delivery.

  12. Evaluation of an immunosuppressant side effect instrument.

    PubMed

    Winsett, Rebecca P; Arheart, Kris; Stratta, Robert J; Alloway, Rita; Wicks, Mona N; Gaber, A Osama; Hathaway, Donna K

    2004-09-01

    Clinicians continue to be compelled to evaluate the impact of immunosuppressive medication side effects on the quality of life of transplant recipients. We Were asked to develop an instrument to measure side effects in immunosuppressed transplant recipients. To construct an instrument that measures the impact and severity of side effects of immunosuppressive medications used in transplantation and to assess the reliability and validity of the newly developed instrument called the Memphis Survey. The instrument was constructed by a panel of physicians, nurses, and pharmacists with experience in treating transplant recipients. A small group of kidney transplant recipients (n= 13) provided pilot data for refining and testing the instrument. A national sample of kidney, liver, and heart transplant recipients (n = 505) provided data that were used to further develop the instrument. Factor analysis was used to determine the psychological dimensions underlying the instrument and to guide the construction of scales from the survey items. The instrument scales were then computed from the dataset of 505 transplant recipients to quantify the impact of immunosuppressant side effects on the quality of life of transplant recipients. Analyses showed the final instrument scales to be valid and reliable. Exploratory analysis suggests the need for further testing of the instrument to determine gender differences.

  13. Evaluation applications of instrument calibration research findings in psychology for very small samples

    NASA Astrophysics Data System (ADS)

    Fisher, W. P., Jr.; Petry, P.

    2016-11-01

    Many published research studies document item calibration invariance across samples using Rasch's probabilistic models for measurement. A new approach to outcomes evaluation for very small samples was employed for two workshop series focused on stress reduction and joyful living conducted for health system employees and caregivers since 2012. Rasch-calibrated self-report instruments measuring depression, anxiety and stress, and the joyful living effects of mindfulness behaviors were identified in peer-reviewed journal articles. Items from one instrument were modified for use with a US population, other items were simplified, and some new items were written. Participants provided ratings of their depression, anxiety and stress, and the effects of their mindfulness behaviors before and after each workshop series. The numbers of participants providing both pre- and post-workshop data were low (16 and 14). Analysis of these small data sets produce results showing that, with some exceptions, the item hierarchies defining the constructs retained the same invariant profiles they had exhibited in the published research (correlations (not disattenuated) range from 0.85 to 0.96). In addition, comparisons of the pre- and post-workshop measures for the three constructs showed substantively and statistically significant changes. Implications for program evaluation comparisons, quality improvement efforts, and the organization of communications concerning outcomes in clinical fields are explored.

  14. Measurement of students' perceptions of nursing as a career.

    PubMed

    Matutina, Robin E; Newman, Susan D; Jenkins, Carolyn M

    2010-09-01

    Middle school has been identified as the prime age group to begin nursing recruitment efforts because students have malleable perceptions about nursing as a future career choice. The purpose of this integrative review is to present a brief overview of research processes related to middle school students' perceptions of nursing as a future career choice and to critically evaluate the current instruments used to measure middle and high school students' perceptions of nursing as a career choice. An integrative review of the years 1989 to 2009 was conducted searching Cumulative Index to Nursing and Allied Health Literature (CINAHL), National Library of Medicine PubMed service (PubMed), and Ovid MEDLINE databases using the key words career, choice, future, ideal, nursing, and perception. Reference lists of retrieved studies were hand searched, yielding a total of 22 studies. Inclusion criteria were (a) sample of middle school students, (b) sample of high school students, (c) mixed sample including middle or high school students, and (4) samples other than middle or high school students if the instrument was tested with middle or high school students in a separate study. Ten studies met these criteria. Of the 10 studies, samples were 30% middle school students; 40% high school students; 10% mixed, including school-aged students; and 20% college students with an instrument tested in middle school students. Eighty percent of participants were White females. Overall, participants' socioeconomic status was not identified. A single study included a theoretical framework. Five instruments were identified and each could be completed in 15 to 30 min. The most commonly used instrument is available free of charge. Seventy percent of the studies used Cronbach's alpha to report instrument reliability (0.63 to 0.93), whereas 30% failed to report reliability. Fifty percent of the studies established validity via a "panel of experts," with three of those studies further describing the panel of experts. Samples of white females may hinder generalization. Socioeconomic status was not consistently reported and may be an important factor with regard to perceptions of nursing as a career choice. An overall absence of theoretical framework hinders empirical data from being applied to nursing theories that in turn may support nursing concepts. The reporting of reliability and validity may be improved by further defining panel of experts and expanding the number of experts (more than seven). More in-depth evaluation of the psychometric properties of the instruments with more diverse populations is needed. Rigorously tested instruments may be useful in determining middle school students' perceptions about nursing. Therefore, future researchers should consider testing existing instruments in the middle school population, adhering to theoretical frameworks, diversifying the sample population, and clearly reporting reliability and validity to gain knowledge about middle school students' perceptions about a nursing career.

  15. Effect of autoclaving on the surfaces of TiN -coated and conventional nickel-titanium rotary instruments.

    PubMed

    Spagnuolo, G; Ametrano, G; D'Antò, V; Rengo, C; Simeone, M; Riccitiello, F; Amato, M

    2012-12-01

    To evaluate the effects of repeated autoclave sterilization cycles on surface topography of conventional nickel-titanium ( NiTi ) and titanium nitride ( TiN )-coated rotary instruments. A total of 60 NiTi rotary instruments, 30 ProTaper (Dentsply Maillefer) and 30 TiN -coated AlphaKite (Komet/Gebr. Brasseler), were analysed. Instruments were evaluated in the as-received condition and after 1, 5 and 10 sterilization cycles. After sterilization, the samples were observed using scanning electron microscope (SEM), and surface chemical analysis was performed on each instrument with energy dispersive X-ray spectroscopy (EDS). Moreover, the samples were analysed by atomic force microscopy (AFM), and roughness average (Ra) and the root mean square value (RMS) of the scanned surface profiles were recorded. Data were analysed by means of anova followed by Tukey's test. Scanning electron microscope observations revealed the presence of pitting and deep milling marks in all instruments. EDS analysis confirmed that both types of instruments were composed mainly of nickel and titanium, whilst AlphaKite had additional nitride. After multiple autoclave sterilization cycles, SEM examinations revealed an increase in surface alterations, and EDS values indicated changes in chemical surface composition in all instruments. Ra and RMS values of ProTaper significantly increased after 5 (P = 0.006) and 10 cycles (P = 0.002) with respect to the as-received instruments, whilst AlphaKite showed significant differences compared with the controls after 10 cycles (P = 0.03). Multiple autoclave sterilization cycles modified the surface topography and chemical composition of conventional and TiN -coated NiTi rotary instruments. © 2012 International Endodontic Journal.

  16. Continuous flow electrophoresis system experiments on shuttle flights STS-6 and STS-7

    NASA Technical Reports Server (NTRS)

    Snyder, Robert S.; Rhodes, Percy H.; Miller, Teresa Y.

    1987-01-01

    A space continuous flow electrophoresis system (CFES) was developed that would incorporate specific modifications to laboratory instruments to take advantage of weightlessness. The specific objectives were to use a model sample material at a high concentration to evaluate the continuous flow electrophoresis process in the CFES instrument and compare its separation resolution and sample throughput with related devices on Earth and to expand the basic knowledge of the limitations imposed by fluid flows and particle concentration effects on the electrophoresis process by careful design and evaluation of the space experiment. Hemoglobin and polysaccharide were selected as primary samples. The results from space show a large band spread of the high concentration of the single species of hemoglobin that was due to the mismatch of electrical conductivity between the sample and the buffer. On STS-7 the major objective was to evaluate the influence of the electrical properties of the sample constituents on the resolution of the CFES. As expected, the polystyrene latex microspheres dispersed in a solution with 3 times the electrical conductivity of the curtain buffer separated with a larger band spread than in the 2nd experiment.

  17. Influence of the Apical Preparation Size and the Irrigant Type on Bacterial Reduction in Root Canal-treated Teeth with Apical Periodontitis.

    PubMed

    Rodrigues, Renata Costa Val; Zandi, Homan; Kristoffersen, Anne Karin; Enersen, Morten; Mdala, Ibrahimu; Ørstavik, Dag; Rôças, Isabela N; Siqueira, José F

    2017-07-01

    This clinical study evaluated the influence of the apical preparation size using nickel-titanium rotary instrumentation and the effect of a disinfectant on bacterial reduction in root canal-treated teeth with apical periodontitis. Forty-three teeth with posttreatment apical periodontitis were selected for retreatment. Teeth were randomly divided into 2 groups according to the irrigant used (2.5% sodium hypochlorite [NaOCl], n = 22; saline, n = 21). Canals were prepared with the Twisted File Adaptive (TFA) system (SybronEndo, Orange, CA). Bacteriological samples were taken before preparation (S1), after using the first instrument (S2), and then after the third instrument of the TFA system (S3). In the saline group, an additional sample was taken after final irrigation with 1% NaOCl (S4). DNA was extracted from the clinical samples and subjected to quantitative real-time polymerase chain reaction to evaluate the levels of total bacteria and streptococci. S1 from all teeth were positive for bacteria. Preparation to the first and third instruments from the TFA system showed a highly significant intracanal bacterial reduction regardless of the irrigant (P < .01). Apical enlargement to the third instrument caused a significantly higher decrease in bacterial counts than the first instrument (P < .01). Intergroup comparison revealed no significant difference between NaOCl and saline after the first instrument (P > .05). NaOCl was significantly better than saline after using the largest instrument in the series (P < .01). Irrespective of the type of irrigant, an increase in the apical preparation size significantly enhanced root canal disinfection. The disinfecting benefit of NaOCl over saline was significant at large apical preparation sizes. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  18. Evaluation of Instrumental Activities of Daily Living in Greek Patients with Advanced Cancer

    ERIC Educational Resources Information Center

    Mystakidou, Kyriaki; Parpa, Efi; Tsilika, Eleni; Panagiotoua, Irene; Roumeliotou, Anna; Symeonidi, Matina; Galanos, Antonis; Kouvaris, Ioannis

    2013-01-01

    Translation of the instrumental activities of daily living (IADL) was carried out and its psychometric properties were assessed in a Greek sample of patients with advanced cancer. The scale was translated with the forward-backward procedure into the Greek language. It was initially administered to 136 advanced cancer patients. To assess…

  19. Developing Instruments Concerning Scientific Epistemic Beliefs and Goal Orientations in Learning Science: A Validation Study

    ERIC Educational Resources Information Center

    Lin, Tzung-Jin; Tsai, Chin-Chung

    2017-01-01

    The purpose of this study was to develop and validate two survey instruments to evaluate high school students' scientific epistemic beliefs and goal orientations in learning science. The initial relationships between the sampled students' scientific epistemic beliefs and goal orientations in learning science were also investigated. A final valid…

  20. Assessing Probabilistic Reasoning in Verbal-Numerical and Graphical-Pictorial Formats: An Evaluation of the Psychometric Properties of an Instrument

    ERIC Educational Resources Information Center

    Agus, Mirian; Penna, Maria Pietronilla; Peró-Cebollero, Maribel; Guàrdia-Olmos, Joan

    2016-01-01

    Research on the graphical facilitation of probabilistic reasoning has been characterised by the effort expended to identify valid assessment tools. The authors developed an assessment instrument to compare reasoning performances when problems were presented in verbal-numerical and graphical-pictorial formats. A sample of undergraduate psychology…

  1. Teachers' Autonomy in Today's Educational Climate: Current Perceptions from an Acceptable Instrument

    ERIC Educational Resources Information Center

    Strong, Luman E. G.; Yoshida, Roland K.

    2014-01-01

    This research evaluated the psychometric properties of Friedman's (1999) Teacher Work-Autonomy Scale (TWA) to determine whether it was an acceptable instrument to measure U.S. teacher autonomy in the present educational context. A second purpose was to ascertain the current status of teachers' perceptions of their autonomy from a sample of U.S.…

  2. Evaluation of NASA speech encoder

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Techniques developed by NASA for spaceflight instrumentation were used in the design of a quantizer for speech-decoding. Computer simulation of the actions of the quantizer was tested with synthesized and real speech signals. Results were evaluated by a phometician. Topics discussed include the relationship between the number of quantizer levels and the required sampling rate; reconstruction of signals; digital filtering; speech recording, sampling, and storage, and processing results.

  3. Noncontact three-dimensional evaluation of surface alterations and wear in NiTi endodontic instruments.

    PubMed

    Ferreira, Fabiano Guerra; Barbosa, Igor Bastos; Scelza, Pantaleo; Montagnana, Marcello Bulhões; Russano, Daniel; Neff, John; Scelza, Miriam Zaccaro

    2017-09-28

    The aim of this study was to undertake a qualitative and quantitative assessment of nanoscale alterations and wear on the surfaces of nickel-titanium (NiTi) endodontic instruments, before and after use, through a high-resolution, noncontact, three-dimensional optical profiler, and to verify the accuracy of the evaluation method. Cutting blade surfaces of two different brands of NiTi endodontic instruments, Reciproc R25 (n = 5) and WaveOne Primary (n = 5), were examined and compared before and after two uses in simulated root canals made in clear resin blocks. The analyses were performed on three-dimensional images which were obtained from surface areas measuring 211 × 211 µm, located 3 mm from their tips. The quantitative evaluation of the samples was conducted before and after the first and second usage, by the recordings of three amplitude parameters. The data were subjected to statistical analysis at a 5% level of significance. The results revealed statistically significant increases in the surface wear of both instruments groups after the second use. The presence of irregularities was found on the surface topography of all the instruments, before and after use. Regardless of the evaluation stage, most of the defects were observed in the WaveOne instruments. The three-dimensional technique was suitable and effective for the accurate investigation of the same surfaces of the instruments in different periods of time.

  4. [The evaluation of nursing graduates' scientific reasoning and oral and written communication].

    PubMed

    Demandes, Ingrid; Latrach, Cecilia A; Febre, Naldy Pamela; Muñoz, Claudia; Torres, Pamela; Retamal, Jessica

    2012-08-01

    This descriptive, cross-sectional study was performed in Santiago de Chile, with the objective to evaluate the scientific reasoning and the oral and written communication of nursing graduates. The sample consisted of 37 nursing graduates who participated in the three stages of the study: I) creation and validation of the instrument; II) training the faculty participating in the study to apply the instrument uniformly; and III) application of the instrument and data analysis. The data show different percentages regarding this competency, with the predominance of scientific reasoning (83.16%), followed by oral and written communication (78.37%). In conclusion, this study demonstrates the value for nursing schools to implement a formal evaluation that allows for determining the profile of nursing graduates, guaranteeing the quality of their training and education.

  5. Evaluation of a new tear osmometer for repeatability and accuracy, using 0.5-microL (500-Nanoliter) samples.

    PubMed

    Yildiz, Elvin H; Fan, Vincent C; Banday, Hina; Ramanathan, Lakshmi V; Bitra, Ratna K; Garry, Eileen; Asbell, Penny A

    2009-07-01

    To evaluate the repeatability and accuracy of a new tear osmometer that measures the osmolality of 0.5-microL (500-nanoliter) samples. Four standardized solutions were tested with 0.5-microL (500-nanoliter) samples for repeatability of measurements and comparability to standardized technique. Two known standard salt solutions (290 mOsm/kg H2O, 304 mOsm/kg H2O), a normal artificial tear matrix sample (306 mOsm/kg H2O), and an abnormal artificial tear matrix sample (336 mOsm/kg H2O) were repeatedly tested (n = 20 each) for osmolality with use of the Advanced Instruments Model 3100 Tear Osmometer (0.5-microL [500-nanoliter] sample size) and the FDA-approved Advanced Instruments Model 3D2 Clinical Osmometer (250-microL sample size). Four standard solutions were used, with osmolality values of 290, 304, 306, and 336 mOsm/kg H2O. The respective precision data, including the mean and standard deviation, were: 291.8 +/- 4.4, 305.6 +/- 2.4, 305.1 +/- 2.3, and 336.4 +/- 2.2 mOsm/kg H2O. The percent recoveries for the 290 mOsm/kg H2O standard solution, the 304 mOsm/kg H2O reference solution, the normal value-assigned 306 mOsm/kg H2O sample, and the abnormal value-assigned 336 mOsm/kg H2O sample were 100.3, 100.2, 99.8, and 100.3 mOsm/kg H2O, respectively. The repeatability data are in accordance with data obtained on clinical osmometers with use of larger sample sizes. All 4 samples tested on the tear osmometer have osmolality values that correlate well to the clinical instrument method. The tear osmometer is a suitable instrument for testing the osmolality of microliter-sized samples, such as tears, and therefore may be useful in diagnosing, monitoring, and classifying tear abnormalities such as the severity of dry eye disease.

  6. Internal preference mapping of milk-fruit beverages: Influence of color and appearance on its acceptability.

    PubMed

    Fernández-Vázquez, Rocío; Stinco, Carla M; Hernanz Vila, Dolores; Heredia, Francisco J; Chaya, Carolina; Vicario, Isabel M

    2018-01-01

    The individual preferences of 100 consumers between 20 and 30 years old for the color of 16 milk-fruit juice beverages (MFJB) were investigated by preference mapping technique. Consumers were asked to evaluate, just by looking at the samples, how much they liked them (from "Extremely dislike" to "Extremely like"). The color of the samples was analyzed by two different instrumental techniques. Results obtained from the instrumental color measurement showed the wide diversity in hues of the beverages available in the market, and correlations between techniques proved that both of them were appropriate to analyze color. Results showed that participants preferred samples with orangish appearance instead of those with a whiter look. Anyway, punctuations given by the consumers suggest that generally, color of these products is not highly evaluated by consumers, as the best mean punctuation was 6.6.

  7. Comparing near-infrared conventional diffuse reflectance spectroscopy and hyperspectral imaging for determination of the bulk properties of solid samples by multivariate regression: determination of Mooney viscosity and plasticity indices of natural rubber.

    PubMed

    Juliano da Silva, Carlos; Pasquini, Celio

    2015-01-21

    Conventional reflectance spectroscopy (NIRS) and hyperspectral imaging (HI) in the near-infrared region (1000-2500 nm) are evaluated and compared, using, as the case study, the determination of relevant properties related to the quality of natural rubber. Mooney viscosity (MV) and plasticity indices (PI) (PI0 - original plasticity, PI30 - plasticity after accelerated aging, and PRI - the plasticity retention index after accelerated aging) of rubber were determined using multivariate regression models. Two hundred and eighty six samples of rubber were measured using conventional and hyperspectral near-infrared imaging reflectance instruments in the range of 1000-2500 nm. The sample set was split into regression (n = 191) and external validation (n = 95) sub-sets. Three instruments were employed for data acquisition: a line scanning hyperspectral camera and two conventional FT-NIR spectrometers. Sample heterogeneity was evaluated using hyperspectral images obtained with a resolution of 150 × 150 μm and principal component analysis. The probed sample area (5 cm(2); 24,000 pixels) to achieve representativeness was found to be equivalent to the average of 6 spectra for a 1 cm diameter probing circular window of one FT-NIR instrument. The other spectrophotometer can probe the whole sample in only one measurement. The results show that the rubber properties can be determined with very similar accuracy and precision by Partial Least Square (PLS) regression models regardless of whether HI-NIR or conventional FT-NIR produce the spectral datasets. The best Root Mean Square Errors of Prediction (RMSEPs) of external validation for MV, PI0, PI30, and PRI were 4.3, 1.8, 3.4, and 5.3%, respectively. Though the quantitative results provided by the three instruments can be considered equivalent, the hyperspectral imaging instrument presents a number of advantages, being about 6 times faster than conventional bulk spectrometers, producing robust spectral data by ensuring sample representativeness, and minimizing the effect of the presence of contaminants.

  8. Patient Evaluation of Emotional Comfort Experienced (PEECE): developing and testing a measurement instrument

    PubMed Central

    Lester, L; Bulsara, C; Petterson, A; Bennett, K; Allen, E; Joske, D

    2017-01-01

    Objectives The Patient Evaluation of Emotional Comfort Experienced (PEECE) is a 12-item questionnaire which measures the mental well-being state of emotional comfort in patients. The instrument was developed using previous qualitative work and published literature. Design Instrument development. Setting Acute Care Public Hospital, Western Australia. Participants Sample of 374 patients. Interventions A multidisciplinary expert panel assessed the face and content validity of the instrument and following a pilot study, the psychometric properties of the instrument were explored. Main outcome measures Exploratory and confirmatory factor analysis assessed the underlying dimensions of the PEECE instrument; Cronbach's α was used to determine the reliability; κ was used for test–retest reliability of the ordinal items. Results 2 factors were identified in the instrument and named ‘positive emotions’ and ‘perceived meaning’. A greater proportion of male patients were found to report positive emotions compared with female patients. The instrument was found to be feasible, reliable and valid for use with inpatients and outpatients. Conclusions PEECE was found to be a feasible instrument for use with inpatient and outpatients, being easily understood and completed. Further psychometric testing is recommended. PMID:28122833

  9. Determination of industrial color tolerance limits: case studies in the textile industry

    NASA Astrophysics Data System (ADS)

    Gay, Jennifer; Hirschler, Robert

    2002-06-01

    The approach and findings during the application of instrumental color quality control in industry are described, where the best tolerance formulae and tolerance limits were determined by correlating visual and instrumental evaluations. A panel of previously tested observers evaluated a collection of samples taken from production and color measurements are then compared to these assessments, according to different color difference formulae. T he formula and the limit giving the best agreement with visual evaluations were determined with two different methods. For a large variety of textile substrates, processes and market situations the CMC(2:1) formula was always the best or one of the bests, but the limits varied widely, according to the individual application. Additional shade sorting, based on the tolerance limit, was also applied in several companies. The ideal box size was also determined by comparing visual and instrumental evaluations. The application as logistical tools was established according to individual necessities.

  10. Instrumental and statistical methods for the comparison of class evidence

    NASA Astrophysics Data System (ADS)

    Liszewski, Elisa Anne

    Trace evidence is a major field within forensic science. Association of trace evidence samples can be problematic due to sample heterogeneity and a lack of quantitative criteria for comparing spectra or chromatograms. The aim of this study is to evaluate different types of instrumentation for their ability to discriminate among samples of various types of trace evidence. Chemometric analysis, including techniques such as Agglomerative Hierarchical Clustering, Principal Components Analysis, and Discriminant Analysis, was employed to evaluate instrumental data. First, automotive clear coats were analyzed by using microspectrophotometry to collect UV absorption data. In total, 71 samples were analyzed with classification accuracy of 91.61%. An external validation was performed, resulting in a prediction accuracy of 81.11%. Next, fiber dyes were analyzed using UV-Visible microspectrophotometry. While several physical characteristics of cotton fiber can be identified and compared, fiber color is considered to be an excellent source of variation, and thus was examined in this study. Twelve dyes were employed, some being visually indistinguishable. Several different analyses and comparisons were done, including an inter-laboratory comparison and external validations. Lastly, common plastic samples and other polymers were analyzed using pyrolysis-gas chromatography/mass spectrometry, and their pyrolysis products were then analyzed using multivariate statistics. The classification accuracy varied dependent upon the number of classes chosen, but the plastics were grouped based on composition. The polymers were used as an external validation and misclassifications occurred with chlorinated samples all being placed into the category containing PVC.

  11. Sensorization of a surgical robotic instrument for force sensing

    NASA Astrophysics Data System (ADS)

    Shahzada, Kaspar S.; Yurkewich, Aaron; Xu, Ran; Patel, Rajni V.

    2016-03-01

    This paper presents the development and application of an approach for sensorizing a surgical robotic instrument for two degree-of-freedom (DOF) lateral force sensing. The sensorized instrument is compatible with the da Vinci® Surgical System and can be used for skills assessment and force control in specific surgical tasks. The sensing technology utilizes a novel layout of four fiber Bragg grating (FBG) sensors attached to the shaft of a da Vinci® surgical instrument. The two cross-section layout is insensitive to error caused by combined force and torque loads, and the orientation of the sensors minimizes the condition number of the instrument's compliance matrix. To evaluate the instrument's sensing capabilities, its performance was tested using a commercially available force-torque sensor, and showed a resolution of 0.05N at 1 kHz sampling rate. The performance of the sensorized instrument was evaluated by performing three surgical tasks on phantom tissue using the da Vinci® system with the da Vinci Research Kit (dVRK): tissue palpation, knot tightening during suturing and Hem-O-Lok® tightening during knotless suturing. The tasks were designed to demonstrate the robustness of the sensorized force measurement approach. The paper reports the results of further evaluation by a group of expert and novice surgeons performing the three tasks mentioned above.

  12. Analytical characterization of a new mobile X-ray fluorescence and X-ray diffraction instrument combined with a pigment identification case study

    NASA Astrophysics Data System (ADS)

    Van de Voorde, Lien; Vekemans, Bart; Verhaeven, Eddy; Tack, Pieter; De Wolf, Robin; Garrevoet, Jan; Vandenabeele, Peter; Vincze, Laszlo

    2015-08-01

    A new, commercially available, mobile system combining X-ray diffraction and X-ray fluorescence has been evaluated which enables both elemental analysis and phase identification simultaneously. The instrument makes use of a copper or molybdenum based miniature X-ray tube and a silicon-Pin diode energy-dispersive detector to count the photons originating from the samples. The X-ray tube and detector are both mounted on an X-ray diffraction protractor in a Bragg-Brentano θ:θ geometry. The mobile instrument is one of the lightest and most compact instruments of its kind (3.5 kg) and it is thus very useful for in situ purposes such as the direct (non-destructive) analysis of cultural heritage objects which need to be analyzed on site without any displacement. The supplied software allows both the operation of the instrument for data collection and in-depth data analysis using the International Centre for Diffraction Data database. This paper focuses on the characterization of the instrument, combined with a case study on pigment identification and an illustrative example for the analysis of lead alloyed printing letters. The results show that this commercially available light-weight instrument is able to identify the main crystalline phases non-destructively, present in a variety of samples, with a high degree of flexibility regarding sample size and position.

  13. Child Sexual Abuse Consequences in Community Samples of Latino and European American Adolescents

    ERIC Educational Resources Information Center

    Newcomb, Michael D.; Munoz, David T.; Carmona, Jennifer Vargas

    2009-01-01

    Objective: Research investigating the impact of child sexual abuse (CSA) in community samples of adolescents has been limited. This study aims to identify sexual abuse among ethnically diverse high school adolescents of both genders and evaluate their psycho-emotional consequences. Method: Through the use of self-report instruments, a sample of…

  14. Effect of added phosphate and type of cooking method on physico-chemical and sensory features of cooked lamb loins.

    PubMed

    Roldán, Mar; Antequera, Teresa; Pérez-Palacios, Trinidad; Ruiz, Jorge

    2014-05-01

    This study evaluated the effect of brining with phosphates on the physico-chemical and sensory features of sous-vide and roasted cooked lamb. Lamb loins (n=48) were injected with either 10% w/w of distilled water or a solution containing 0.2% or 0.4% (w/v) of a mixture of phosphate salts. After injection, samples were either sous-vide cooked (12h-60°C) or oven roasted (180°C until 73°C of core temp.). Expressible moisture, cooking loss, instrumental color, pH, water holding capacity, instrumental texture and sensory properties were evaluated. Brining with phosphates led to lower cooking loss in both sous-vide and oven roasted samples, but only the former showed significantly higher moisture content. Phosphates increased instrumental hardness and shear force values in sous-vide samples, while this effect was not as evident in roasted ones. Toughness was reduced and juiciness was improved as a consequence of phosphate addition. Overall, injection of a phosphate solution appears as a potential procedure for improving sensory textural features of cooked lamb whole cuts. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Critical comparison of mass analyzers for forensic hair analysis by ambient ionization mass spectrometry.

    PubMed

    Duvivier, Wilco F; van Beek, Teris A; Nielen, Michel W F

    2016-11-15

    Recently, several direct and/or ambient mass spectrometry (MS) approaches have been suggested for drugs of abuse imaging in hair. The use of mass spectrometers with insufficient selectivity could result in false-positive measurements due to isobaric interferences. Different mass analyzers have been evaluated regarding their selectivity and sensitivity for the detection of Δ9-tetrahydrocannabinol (THC) from intact hair samples using direct analysis in real time (DART) ionization. Four different mass analyzers, namely (1) an orbitrap, (2) a quadrupole orbitrap, (3) a triple quadrupole, and (4) a quadrupole time-of-flight (QTOF), were evaluated. Selectivity and sensitivity were assessed by analyzing secondary THC standard dilutions on stainless steel mesh screens and blank hair samples, and by the analysis of authentic cannabis user hair samples. Additionally, separation of isobaric ions by use of travelling wave ion mobility (TWIM) was investigated. The use of a triple quadrupole instrument resulted in the highest sensitivity; however, transitions used for multiple reaction monitoring were only found to be specific when using high mass resolution product ion measurements. A mass resolution of at least 30,000 FWHM at m/z 315 was necessary to avoid overlap of THC with isobaric ions originating from the hair matrix. Even though selectivity was enhanced by use of TWIM, the QTOF instrument in resolution mode could not indisputably differentiate THC from endogenous isobaric ions in drug user hair samples. Only the high resolution of the (quadrupole) orbitrap instruments and the QTOF instrument in high-resolution mode distinguished THC in hair samples from endogenous isobaric interferences. As expected, enhanced selectivity compromises sensitivity and THC was only detectable in hair from heavy users. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  16. Low-Level Analytical Methodology Updates to Support Decontaminant Performance Evaluations

    DTIC Science & Technology

    2011-06-01

    from EPDM and tire rubber coupon materials that were spiked with a known amount of the chemical agent VX, treated with bleach decontaminant, and...to evaluate the performance of bleach decontaminant on EPDM and tire rubber coupons. Dose-confirmation or Tool samples were collected by delivering...components • An aging or damaged analytical column • Dirty detector • Other factors related to general instrument and/or sample analysis performance

  17. Psychometric Evaluation of an Instrument for Measuring Organizational Climate for Quality: Evidence From a National Sample of Infection Preventionists.

    PubMed

    Pogorzelska-Maziarz, Monika; Nembhard, Ingrid M; Schnall, Rebecca; Nelson, Shanelle; Stone, Patricia W

    2016-09-01

    In recent years, there has been increased interest in measuring the climate for infection prevention; however, reliable and valid instruments are lacking. This study tested the psychometric properties of the Leading a Culture of Quality for Infection Prevention (LCQ-IP) instrument measuring the infection prevention climate in a sample of 972 infection preventionists from acute care hospitals. An exploratory principal component analysis showed that the instrument had structural validity and captured 4 factors related to the climate for infection prevention: Psychological Safety, Prioritization of Quality, Supportive Work Environment, and Improvement Orientation. LCQ-IP exhibited excellent internal consistency, with a Cronbach α of .926. Criterion validity was supported with overall LCQ-IP scores, increasing with the number of evidence-based prevention policies in place (P = .047). This psychometrically sound instrument may be helpful to researchers and providers in assessing climate for quality related to infection prevention. © The Author(s) 2015.

  18. Predicting violence and recidivism in a large sample of males on probation or parole.

    PubMed

    Prell, Lettie; Vitacco, Michael J; Zavodny, Denis

    This study evaluated the utility of items and scales from the Iowa Violence and Victimization Instrument in a sample of 1961 males from the state of Iowa who were on probation or released from prison to parole supervision. This is the first study to examine the potential of the Iowa Violence and Victimization Instrument to predict criminal offenses. The males were followed for 30months immediately following their admission to probation or parole. AUC analyses indicated fair to good predictive power for the Iowa Violence and Victimization Instrument for charges of violence and victimization, but chance predictive power for drug offenses. Notably, both scales of the instrument performed equally well at the 30-month follow-up. Items on the Iowa Violence and Victimization Instrument not only predicted violence, but are straightforward to score. Violence management strategies are discussed as they relate to the current findings, including the potential to expand the measure to other jurisdictions and populations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Cross-cultural feigning assessment: A systematic review of feigning instruments used with linguistically, ethnically, and culturally diverse samples.

    PubMed

    Nijdam-Jones, Alicia; Rosenfeld, Barry

    2017-11-01

    The cross-cultural validity of feigning instruments and cut-scores is a critical concern for forensic mental health clinicians. This systematic review evaluated feigning classification accuracy and effect sizes across instruments and languages by summarizing 45 published peer-reviewed articles and unpublished doctoral dissertations conducted in Europe, Asia, and North America using linguistically, ethnically, and culturally diverse samples. The most common psychiatric symptom measures used with linguistically, ethnically, and culturally diverse samples included the Structured Inventory of Malingered Symptomatology, the Miller Forensic Assessment of Symptoms Test, and the Minnesota Multiphasic Personality Inventory (MMPI). The most frequently studied cognitive effort measures included the Word Recognition Test, the Test of Memory Malingering, and the Rey 15-item Memory test. The classification accuracy of these measures is compared and the implications of this research literature are discussed. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  20. Seeking excellence: An evaluation of 235 international laboratories conducting water isotope analyses by isotope-ratio and laser-absorption spectrometry.

    PubMed

    Wassenaar, L I; Terzer-Wassmuth, S; Douence, C; Araguas-Araguas, L; Aggarwal, P K; Coplen, T B

    2018-03-15

    Water stable isotope ratios (δ 2 H and δ 18 O values) are widely used tracers in environmental studies; hence, accurate and precise assays are required for providing sound scientific information. We tested the analytical performance of 235 international laboratories conducting water isotope analyses using dual-inlet and continuous-flow isotope ratio mass spectrometers and laser spectrometers through a water isotope inter-comparison test. Eight test water samples were distributed by the IAEA to international stable isotope laboratories. These consisted of a core set of five samples spanning the common δ-range of natural waters, and three optional samples (highly depleted, enriched, and saline). The fifth core sample contained unrevealed trace methanol to assess analyst vigilance to the impact of organic contamination on water isotopic measurements made by all instrument technologies. For the core and optional samples ~73 % of laboratories gave acceptable results within 0.2 ‰ and 1.5 ‰ of the reference values for δ 18 O and δ 2 H, respectively; ~27 % produced unacceptable results. Top performance for δ 18 O values was dominated by dual-inlet IRMS laboratories; top performance for δ 2 H values was led by laser spectrometer laboratories. Continuous-flow instruments yielded comparatively intermediate results. Trace methanol contamination of water resulted in extreme outlier δ-values for laser instruments, but also affected reactor-based continuous-flow IRMS systems; however, dual-inlet IRMS δ-values were unaffected. Analysis of the laboratory results and their metadata suggested inaccurate or imprecise performance stemmed mainly from skill- and knowledge-based errors including: calculation mistakes, inappropriate or compromised laboratory calibration standards, poorly performing instrumentation, lack of vigilance to contamination, or inattention to unreasonable isotopic outcomes. To counteract common errors, we recommend that laboratories include 1-2 'known' control standards in all autoruns; laser laboratories should screen each autorun for spectral contamination; and all laboratories should evaluate whether derived d-excess values are realistic when both isotope ratios are measured. Combined, these data evaluation strategies should immediately inform the laboratory about fundamental mistakes or compromised samples. Copyright © 2018 John Wiley & Sons, Ltd.

  1. Seeking excellence: An evaluation of 235 international laboratories conducting water isotope analyses by isotope-ratio and laser-absorption spectrometry

    USGS Publications Warehouse

    Wassenaar, L. I.; Terzer-Wassmuth, S.; Douence, C.; Araguas-Araguas, L.; Aggarwal, P. K.; Coplen, Tyler B.

    2018-01-01

    RationaleWater stable isotope ratios (δ2H and δ18O values) are widely used tracers in environmental studies; hence, accurate and precise assays are required for providing sound scientific information. We tested the analytical performance of 235 international laboratories conducting water isotope analyses using dual-inlet and continuous-flow isotope ratio mass spectrometers and laser spectrometers through a water isotope inter-comparison test.MethodsEight test water samples were distributed by the IAEA to international stable isotope laboratories. These consisted of a core set of five samples spanning the common δ-range of natural waters, and three optional samples (highly depleted, enriched, and saline). The fifth core sample contained unrevealed trace methanol to assess analyst vigilance to the impact of organic contamination on water isotopic measurements made by all instrument technologies.ResultsFor the core and optional samples ~73 % of laboratories gave acceptable results within 0.2 ‰ and 1.5 ‰ of the reference values for δ18O and δ2H, respectively; ~27 % produced unacceptable results. Top performance for δ18O values was dominated by dual-inlet IRMS laboratories; top performance for δ2H values was led by laser spectrometer laboratories. Continuous-flow instruments yielded comparatively intermediate results. Trace methanol contamination of water resulted in extreme outlier δ-values for laser instruments, but also affected reactor-based continuous-flow IRMS systems; however, dual-inlet IRMS δ-values were unaffected.ConclusionsAnalysis of the laboratory results and their metadata suggested inaccurate or imprecise performance stemmed mainly from skill- and knowledge-based errors including: calculation mistakes, inappropriate or compromised laboratory calibration standards, poorly performing instrumentation, lack of vigilance to contamination, or inattention to unreasonable isotopic outcomes. To counteract common errors, we recommend that laboratories include 1–2 'known' control standards in all autoruns; laser laboratories should screen each autorun for spectral contamination; and all laboratories should evaluate whether derived d-excess values are realistic when both isotope ratios are measured. Combined, these data evaluation strategies should immediately inform the laboratory about fundamental mistakes or compromised samples.

  2. Advanced sampling techniques for hand-held FT-IR instrumentation

    NASA Astrophysics Data System (ADS)

    Arnó, Josep; Frunzi, Michael; Weber, Chris; Levy, Dustin

    2013-05-01

    FT-IR spectroscopy is the technology of choice to identify solid and liquid phase unknown samples. The challenging ConOps in emergency response and military field applications require a significant redesign of the stationary FT-IR bench-top instruments typically used in laboratories. Specifically, field portable units require high levels of resistance against mechanical shock and chemical attack, ease of use in restrictive gear, extreme reliability, quick and easy interpretation of results, and reduced size. In the last 20 years, FT-IR instruments have been re-engineered to fit in small suitcases for field portable use and recently further miniaturized for handheld operation. This article introduces the HazMatID™ Elite, a FT-IR instrument designed to balance the portability advantages of a handheld device with the performance challenges associated with miniaturization. In this paper, special focus will be given to the HazMatID Elite's sampling interfaces optimized to collect and interrogate different types of samples: accumulated material using the on-board ATR press, dispersed powders using the ClearSampler™ tool, and the touch-to-sample sensor for direct liquid sampling. The application of the novel sample swipe accessory (ClearSampler) to collect material from surfaces will be discussed in some detail. The accessory was tested and evaluated for the detection of explosive residues before and after detonation. Experimental results derived from these investigations will be described in an effort to outline the advantages of this technology over existing sampling methods.

  3. A New Method for Endoscopic Sampling of Submucosal Tissue in the Gastrointestinal Tract: A Comparison of the Biopsy Forceps and a New Drill Instrument.

    PubMed

    Walther, Charles; Jeremiasen, Martin; Rissler, Pehr; Johansson, Jan L M; Larsson, Marie S; Walther, Bruno S C S

    2016-12-01

    Background Sampling of submucosal lesions in the gastrointestinal tract through a flexible endoscope is a well-recognized clinical problem. One technique often used is endoscopic ultrasound-guided fine-needle aspiration, but it does not provide solid tissue biopsies with preserved architecture for histopathological evaluation. To obtain solid tissue biopsies from submucosal lesions, we have constructed a new endoscopic biopsy tool and compared it in a crossover study with the standard double cupped forceps. Methods Ten patients with endoscopically verified submucosal lesions were sampled. The endoscopist selected the position for the biopsies and used the instrument selected by randomization. After a biopsy was harvested, the endoscopist chose the next site for a biopsy and again used the instrument picked by randomization. A total of 6 biopsies, 3 with the forceps and 3 with the drill instrument, were collected in every patient. Results The drill instrument resulted in larger total size biopsies (mm 2 ; Mann-Whitney U test, P = .048) and larger submucosal part (%) of the biopsies (Mann-Whitney U test, P = .003) than the forceps. Two patients were observed because of chest pain and suspicion of bleeding in 24 hours. No therapeutic measures were necessary to be taken. Conclusion The new drill instrument for flexible endoscopy can safely deliver submucosal tissue samples from submucosal lesions in the upper gastrointestinal tract. © The Author(s) 2016.

  4. A gel-based visual immunoassay for non-instrumental detection of chloramphenicol in food samples.

    PubMed

    Yuan, Meng; Sheng, Wei; Zhang, Yan; Wang, Junping; Yang, Yijin; Zhang, Shuguang; Goryacheva, Irina Yu; Wang, Shuo

    2012-11-02

    A gel-based non-instrumental immuno-affinity assay was developed for the rapid screening of chloramphenicol (CAP) in food samples with the limit of detection (LOD) of 1 μg L(-1). The immuno-affinity test column (IATC) consisted of a test layer containing anti-CAP antibody coupled gel, and a control layer with anti-HRP antibody coupled gel. Based on the direct competitive immuno-reaction and the horseradish peroxidase enzymatic reaction, the test results could be evaluated visually. Basically, blue color development represented the negative results, while the absence of color development represented the positive results. In this study, CAP spiked samples of raw milk, pasteurized milk, UHT milk, skimmed milk powder, acacia honey, date honey, fish and shrimp were tested. Little or none sample pretreatment was required for this assay. The whole procedure was completed within 10min. In conclusion, the gel-based immuno-affinity test is a simple, rapid, and promising on-site screening method for CAP residues in food samples, with no instrumental requirement. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Evaluation of a User Information Satisfaction Short-Form Instrument.

    DTIC Science & Technology

    1992-03-01

    from the bottom roots [34]. SAS has the capability of computing the Kaiser - Meyer - Olkin (MSA option) measure of sampling adequacy [33]. The MSA is a...msa /* Kaiser Measure of Sampling Adequacy - Sphericity */ scree heywood n=l rotate=varimax reorder; title3 "Maximum Likeliness Factor Analysis with One

  6. A comparative evaluation of two rotary Ni-Ti instruments in the removal of gutta-percha during retreatment.

    PubMed

    Preetam, C S; Chandrashekhar, M; Gunaranjan, T; Kumar, S Kishore; Miskeen Sahib, S A; Kumar, M Senthil

    2016-08-01

    The purpose of this study is to achieve an effective method to remove root canal filling material from the root canal system. The study, thus, aims to evaluate the efficacy of the cleaning ability of two different rotary Ni-Ti systems; ProTaper Retreatment files and RaCe System compared to hand instrumentation with Hedstrom files for the removal of gutta-percha during retreatment. Thirty mandibular premolars with one single straight canal were decoronated and instrumented with ProTaper files and filled with thermoplastic gutta-percha. After 30 days, the samples were divided into three groups and gutta-percha was removed with the test instruments. The postoperative radiographs were evaluated with known criteria by dividing the root into cervical third, middle third, and apical third. The results were tabulated and Statistical Package for Social Sciences Software (IBM Corporation) was used for analysis. The mean deviation of the results were first calculated and then t-test and analysis of variance test (two-tailed P value) were evaluated for establishing significant differences. The rotary instruments were effective in removing the gutta-percha from the canals. Therefore, significant difference was observed between the efficacies of the two rotary systems used. The rotary instruments showed effective gutta-percha removal in the cervical and middle one third. (P > 0.05). However, apical debridement was effective with Hedstrom files. The study concluded the use of both rotary and hand instrumentation for effective removal of gutta-percha for retreatment.

  7. Evaluation of Rock Powdering Methods to Obtain Fine-grained Samples for CHEMIN, a Combined XRD/XRF Instrument

    NASA Technical Reports Server (NTRS)

    Chipera, S. J.; Vaniman, D. T.; Bish, D. L.; Sarrazin, P.; Feldman, S.; Blake, D. F.; Bearman, G.; Bar-Cohen, Y.

    2004-01-01

    A miniature XRD/XRF (X-ray diffraction / X-ray fluorescence) instrument, CHEMIN, is currently being developed for definitive mineralogic analysis of soils and rocks on Mars. One of the technical issues that must be addressed to enable remote XRD analysis is how best to obtain a representative sample powder for analysis. For powder XRD analyses, it is beneficial to have a fine-grained sample to reduce preferred orientation effects and to provide a statistically significant number of crystallites to the X-ray beam. Although a two-dimensional detector as used in the CHEMIN instrument will produce good results even with poorly prepared powder, the quality of the data will improve and the time required for data collection will be reduced if the sample is fine-grained and randomly oriented. A variety of methods have been proposed for XRD sample preparation. Chipera et al. presented grain size distributions and XRD results from powders generated with an Ultrasonic/Sonic Driller/Corer (USDC) currently being developed at JPL. The USDC was shown to be an effective instrument for sampling rock to produce powder suitable for XRD. In this paper, we compare powder prepared using the USDC with powder obtained with a miniaturized rock crusher developed at JPL and with powder obtained with a rotary tungsten carbide bit to powders obtained from a laboratory bench-scale Retsch mill (provides benchmark mineralogical data). These comparisons will allow assessment of the suitability of these methods for analysis by an XRD/XRF instrument such as CHEMIN.

  8. Determination of solvents permeating through chemical protective clothing with a microsensor array.

    PubMed

    Park, J; Zellers, E T

    2000-08-01

    The performance of a novel prototype instrument in determining solvents and solvent mixtures permeating through samples of chemical protective clothing (CPC) materials was evaluated. The instrument contains a mini-preconcentrator and an array of three polymer-coated surface-acoustic-wave (SAW) microsensors whose collective response patterns are used to discriminate among multiple permeants. Permeation tests were performed with a 2.54 cm diameter test cell in an open-loop configuration on samples of common glove materials challenged with four individual solvents, three binary mixtures, and two ternary mixtures. Breakthrough times, defined as the times required for the permeation rate to reach a value of 1 microg cm(-2) min(-1), determined by the instrument were within 3 min of those determined in parallel by manual sampling and gas chromatographic analysis. Permeating solvents were recognized (identified) from their response patterns in 59 out of 64 measurements (92%) and their vapor concentrations were quantified to an accuracy of +/- 31% (typically +/- 10%). These results demonstrate the potential for such instrumentation to provide semi-automated field or bench-top screening of CPC permeation resistance.

  9. Cyclic fatigue of ProFile rotary instruments after prolonged clinical use.

    PubMed

    Gambarini, G

    2001-07-01

    The purpose of the present study was to evaluate resistance to cyclic fatigue of new and used ProFile Ni-Ti rotary instruments. Used instruments were operated in 10 clinical cases using passive instrumentation and a crown-down preparation technique. Cyclic fatigue testing of new and used engine-driven instruments was then performed with a specific device which allowed the instruments to rotate freely inside a stainless steel artificial canal, whilst maintaining conditions close to the clinical situation. Instruments were rotated until fracture occurred and time to fracture was visually recorded with a chronometer. A significant reduction of rotation time to breakage (life span) was noted between new and used instruments. In all sizes new instruments were significantly more resistant than used ones (two-sample t-test, P < 0.01). No instrument underwent intracanal failure during clinical use. Prolonged clinical use of Ni-Ti engine-driven instruments significantly reduced their cyclic fatigue resistance. Nevertheless, each rotary instrument was successfully operated in up to 10 clinical cases without any intracanal failure.

  10. Clinical evaluation of a new pressure ulcer risk assessment instrument, the Pressure Ulcer Risk Primary or Secondary Evaluation Tool (PURPOSE T).

    PubMed

    Coleman, Susanne; Smith, Isabelle L; McGinnis, Elizabeth; Keen, Justin; Muir, Delia; Wilson, Lyn; Stubbs, Nikki; Dealey, Carol; Brown, Sarah; Nelson, E Andrea; Nixon, Jane

    2018-02-01

    To test the psychometric properties and clinical usability of a new Pressure Ulcer Risk Assessment Instrument including inter-rater and test-retest reliability, convergent validity and data completeness. Methodological and practical limitations associated with traditional Pressure Ulcer Risk Assessment Instruments, prompted a programme to work to develop a new instrument, as part of the National Institute for Health Research funded, Pressure UlceR Programme Of reSEarch (RP-PG-0407-10056). Observational field test. For this clinical evaluation 230 patients were purposefully sampled across four broad levels of pressure ulcer risk with representation from four secondary care and four community NHS Trusts in England. Blinded and simultaneous paired (ward/community nurse and expert nurse) PURPOSE-T assessments were undertaken. Follow-up retest was undertaken by the expert nurse. Field notes of PURPOSE-T use were collected. Data were collected October 2012-January 2013. The clinical evaluation demonstrated "very good" (kappa) inter-rater and test-retest agreement for PURPOSE-T assessment decision overall. The percentage agreement for "problem/no problem" was over 75% for the main risk factors. Convergent validity demonstrated moderate to high associations with other measures of similar constructs. The PURPOSE-T evaluation facilitated the initial validation and clinical usability of the instrument and demonstrated that PURPOSE-T is suitable of use in clinical practice. Further study is needed to evaluate the impact of using the instrument on care processes and outcomes. © 2017 The Authors. Journal of Advanced Nursing Published by John Wiley & Sons Ltd.

  11. Reliability of conventional shade guides in teeth color determination.

    PubMed

    Todorović, Ana; Todorović, Aleksandar; Gostović, Aleksandra Spadijer; Lazić, Vojkan; Milicić, Biljana; Djurisić, Slobodan

    2013-10-01

    Color matching in prosthodontic therapy is a very important task because it influences the esthetic value of dental restorations. Visual shade matching represents the most frequently applied method in clinical practice. Instrumental measurements provide objective and quantified data in color assessment of natural teeth and restorations. In instrumental shade analysis, the goal is to achieve the smallest deltaE value possible, indicating the most accurate shade match. The aim of this study was to evaluate the reliability of commercially available ceramic shade guides. VITA Easyshade spectrophotometer (VITA, Germany) was used for instrumental color determination. Utilizing this device, color samples of ten VITA Classical and ten VITA 3D - Master shade guides were analyzed. Each color sample from all shade guides was measured three times and the basic parameters of color quality were examined: deltaL, deltaC, deltaH, deltaE, deltaElc. Based on these parameters spectrophotometer marks the shade matching as good, fair or adjust. After performing 1,248 measurements of ceramic color samples, frequency of evaluations adjust, fair and good were statistically significantly different between VITA Classical and VITA 3D Master shade guides (p = 0.002). There were 27.1% cases scored as adjust, 66.3% as fair and 6.7% as good. In VITA 3D - Master shade guides 30.9% cases were evaluated as adjust, 66.4% as fair and 2.7% cases as good. Color samples from different shade guides, produced by the same manufacturer, show variability in basic color parameters, which once again proves the lack of precision and nonuniformity of the conventional method.

  12. Relative performance evaluation of a custom-made near infrared reflectance instrument and two commercial instruments (Foss and ASD) in the nondestructive moisture content measurement of in-shell peanuts

    USDA-ARS?s Scientific Manuscript database

    A custom made Near Infrared Reflectance (NIR) spectroscope was used to determine the moisture content of in-shell peanuts of Virginia type peanuts. Peanuts were conditioned to different moisture levels between 6 and 26 % (wet basis) and samples from different moisture levels were separated into two...

  13. Life Sciences Research Facility automation requirements and concepts for the Space Station

    NASA Technical Reports Server (NTRS)

    Rasmussen, Daryl N.

    1986-01-01

    An evaluation is made of the methods and preliminary results of a study on prospects for the automation of the NASA Space Station's Life Sciences Research Facility. In order to remain within current Space Station resource allocations, approximately 85 percent of planned life science experiment tasks must be automated; these tasks encompass specimen care and feeding, cage and instrument cleaning, data acquisition and control, sample analysis, waste management, instrument calibration, materials inventory and management, and janitorial work. Task automation will free crews for specimen manipulation, tissue sampling, data interpretation and communication with ground controllers, and experiment management.

  14. Teacher-Course Evaluation: A Longitudinal Study of Response Stability and Instrument Reliability.

    ERIC Educational Resources Information Center

    McCollester, Charles W.; And Others

    The temporal context within which a teacher and course evaluation (TCE) is completed did not appear to be of crucial importance in affecting TCE responses. A sample of students was asked to evaluate, initially as freshmen and retrospectively as seniors, a specific teacher and course. Additional data on the student's academic status characteristics…

  15. Evaluation of the Impact of Media Marketing Strategies on Continuing Education Enrollments. AIR Forum 1982 Paper.

    ERIC Educational Resources Information Center

    Campbell, Jill F.; Spiro, Louis M.

    The impact of media marketing strategies on continuing education enrollment at the State University of New York College at Brockport (SUNY-CB), was evaluated. The evaluation of advertising impacts used advertising records of SUNY-CB and other area colleges and a telephone questionnaire instrument. A stratified, random countywide sample, in…

  16. [Level of teaching competence at the Undergraduate Medical Internship of UNAM's Faculty of Medicine].

    PubMed

    Martínez-González, Adrián; Lifshitz-Guinzberg, Alberto; González-Quintanilla, Eduardo; Monterrosas-Rojas, Ana María; Flores-Hernández, Fernando; Gatica-Lara, Florina; Martínez-Franco, Adrián Israel; Sánchez-Mendiola, Melchor

    2017-01-01

    There is no systematic evaluation of teaching performance in the clinical area at UNAM Faculty of Medicine. The study purpose is to assess the teaching competence level in the Undergraduate Medical Internship (UMI). The paper describes the process of psychometric validity for the instrument designed to evaluate teaching competence in the UMI. This instrument was constructed from two previously developed instruments. The final version with 54 items in a Likert scale was studied with exploratory factorial analysis. Four dimensions were obtained: Solution of clinical problems, Psychopedagogy, Mentoring, and Evaluation. The instrument had a reliability of 0.994, with an explained variance of 77.75%. To evaluate the teaching competence level, we administered 844 questionnaires to a sample of students with a response rate of 89%. We obtained an overall global score of 89.4 ± 9.6 (mean ± SD). The dimension Solution of clinical problems was the one with a greater value, in contrast with the dimension of Evaluation, which had a lower score. The teachers of the UMI are considered educators with high level of teaching competence, according to the perceptions of the undergraduate internal doctors. The evaluation of teaching competence level is very important for institutions that look for the continuous professional development of its faculty.

  17. The cross-cultural generalizability of Axis-II constructs: an evaluation of two personality disorder assessment instruments in the People's Republic of China.

    PubMed

    Yang, J; McCrae, R R; Costa, P T; Yao, S; Dai, X; Cai, T; Gao, B

    2000-01-01

    We examined the reliability, cross-instrument validity, and factor structure of Chinese adaptations of the Personality Diagnostic Questionnaire (PDQ-4+; N = 1,926) and Personality Disorders Interview (PDI-IV; N = 525) in psychiatric patients. Comparisons with data from Western countries suggest that the psychometric properties of these two instruments are comparable across cultures. Low to modest agreement between the PDQ-4+ and PDI-IV was observed for both dimensional and categorical personality disorder evaluations. When the PDI-IV was used as the diagnostic standard, the PDQ-4+ showed higher sensitivity than specificity, and higher negative predictive power than positive predictive power. Factor analyses of both instruments replicated the four-factor structure O'Connor and Dyce (1998) found in Western samples. Results suggested that conceptions and measures of DSM-IV personality disorders are cross-culturally generalizable to Chinese psychiatric populations.

  18. Comparative study of mobile Raman instrumentation for art analysis.

    PubMed

    Vandenabeele, P; Castro, K; Hargreaves, M; Moens, L; Madariaga, J M; Edwards, H G M

    2007-04-04

    In archaeometry, one of the main concerns is to extract information from an art object, without damaging it. Raman spectroscopy is being applied in this research field with recent developments in mobile instrumentation facilitating more routine analysis. This research paper evaluates the performances of five mobile Raman instruments (Renishaw RA100, Renishaw Portable Raman Analyser RX210, Ocean Optics RSL-1, Delta Nu Inspector Raman, Mobile Art Analyser--MArtA) in three different laboratories. A set of samples were collected, in order to obtain information on the spectral performances of the instruments including: spectral resolution, calibration, laser cut-off, the ability to record spectra of organic and inorganic pigments through varnish layers and on the possibilities to identify biomaterials. Spectra were recorded from predefined regions on a canvas painting to simulate the investigation of artworks and the capabilities to record spectra from hardly accessible areas was evaluated.

  19. Urey: Mars Organic and Oxidant Detector

    NASA Technical Reports Server (NTRS)

    2007-01-01

    [figure removed for brevity, see original site] Annotated Version

    Some key components of a NASA-funded instrument being developed for the payload of the European Space Agency's ExoMars mission stand out in this illustration of the instrument.

    The instrument is the Urey: Mars Organic and Oxidant Detector. It can check for the faintest traces of life's molecular building blocks. If those are present, it can assess whether they were produced by anything alive. It can also evaluate harsh environmental conditions that could be erasing those molecular clues.

    ExoMars is planned as a rover to be launched in 2013 and search on Mars for signs of life.

    Samples of Martian soil collected by a drill on the rover will be delivered to the Urey instrument. The instrument component called the sub-critical water extractor adds water and heats the sample, getting different types of organic compounds to dissolve into the water at different temperatures. The Mars organic detector uses a fluorescent reagent and laser to detect organic chemicals. The micro-capillary electrophoresis component separates different types of organic chemicals from each others for identifying which ones are present in the sample. The Mars oxidant instrument, part of which is on a separately mounted deck unit not pictured, assesses how readily organic material would be broken down by the radiation, atmosphere and soil chemistry of the site.

  20. Psychometric Evaluation of the Child-Adolescent Teasing Scale

    ERIC Educational Resources Information Center

    Vessey, Judith A.; Horowitz, June A.; Carlson, Karen L.; Duffy, Mary

    2008-01-01

    Background: This article presents the psychometric evaluation of the Child-Adolescent Teasing Scale (CATS), an instrument to be used as a screening measure with middle school students. Methods: A 70-item scale was initially derived from qualitative data obtained from focus groups comprised of middle school students. A diverse sample of…

  1. The Bull's-Eye Values Survey: A Psychometric Evaluation

    ERIC Educational Resources Information Center

    Lundgren, Tobias; Luoma, Jason B.; Dahl, JoAnne; Strosahl, Kirk; Melin, Lennart

    2012-01-01

    Two studies were conducted to develop and evaluate an instrument intended to identify and measure personal values, values attainment, and persistence in the face of barriers. Study 1 describes a content validity approach to the construction and preliminary validation of the Bull's Eye Values Survey (BEVS), using a sample of institutionalized…

  2. EVALUATION OF METHODS FOR THE DETERMINATION OF DIESEL-GENERATED FINE PARTICULATE MATTER: PHYSICAL CHARACTERIZATION OF RESULTS

    EPA Science Inventory

    A multi-phase instrument comparison study was conducted on two different diesel engines on a dynamometer to compare commonly used particulate matter (PM) measurement techniques while sampling the same diesel exhaust aerosol and to evaluate inter- and intra-method variability. In...

  3. The ExoMars Sample Preparation and Distribution System

    NASA Astrophysics Data System (ADS)

    Schulte, Wolfgang; Hofmann, Peter; Baglioni, Pietro; Richter, Lutz; Redlich, . Daniel; Notarnicola, Marco; Durrant, Stephen

    2012-07-01

    The Sample Preparation and Distribution System (SPDS) is a key element of the ESA ExoMars Rover. It is a set of complex mechanisms designed to receive Mars soil samples acquired from the subsurface with a drill, to crush them and to distribute the obtained soil powder to the scientific instruments of the `Pasteur Payload', in the Rover Analytical Laboratory (ALD). In particular, the SPDS consists of: (1) a Core Sample Handling System (CSHS), including a Core Sample Transportation Mechanism (CSTM) and a Blank Sample Dispenser; (2) a Crushing Station (CS); (3) a Powder Sample Dosing and Distribution System (PSDDS); and (4) a Powder Sample Handling System (PSHS) which is a carousel carrying pyrolysis ovens, a re-fillable sample container and a tool to flatten the powder sample surface. Kayser-Threde has developed, undercontract with the ExoMars prime contractor Thales Alenia Space Italy, breadboards and an engineering model of the SPDS mechanisms. Tests of individual mechanisms, namely the CSTM, CS and PSDDS were conducted both in laboratory ambient conditions and in a simulated Mars environment, using dedicated facilities. The SPDS functionalities and performances were measured and evaluated. In the course of 2011 the SPDS Dosing Station (part of the PSDDS) was also tested in simulated Mars gravity conditions during a parabolic flight campaign. By the time of the conference, an elegant breadboard of the Powder Sample Handling System will have been built and tested. The next step, planned by mid of 2012, will be a complete end-to-end test of the sample handling and processing chain, combining all four SPDS mechanisms. The possibility to verify interface and operational aspects between the SPDS and the ALD scientific instruments using the available instruments breadboards with the end-to-end set-up is currently being evaluated. This paper illustrates the most recent design status of the SPDS mechanisms, summarizes the test results and highlights future development activities, including potential involvement of the ExoMars science experiments.

  4. Pressure ulcers: development and psychometric evaluation of the attitude towards pressure ulcer prevention instrument (APuP).

    PubMed

    Beeckman, D; Defloor, T; Demarré, L; Van Hecke, A; Vanderwee, K

    2010-11-01

    Pressure ulcers continue to be a significant problem in hospitals, nursing homes and community care settings. Pressure ulcer incidence is widely accepted as an indicator for the quality of care. Negative attitudes towards pressure ulcer prevention may result in suboptimal preventive care. A reliable and valid instrument to assess attitudes towards pressure ulcer prevention is lacking. Development and psychometric evaluation of the Attitude towards Pressure ulcer Prevention instrument (APuP). Prospective psychometric instrument validation study. A literature review was performed to design the instrument. Content validity was evaluated by nine European pressure ulcer experts and five experts in psychometric instrument validation in a double Delphi procedure. A convenience sample of 258 nurses and 291 nursing students from Belgium and The Netherlands participated in order to evaluate construct validity and stability reliability of the instrument. The data were collected between February and May 2008. A factor analysis indicated the construct of a 13 item instrument in a five factor solution: (1) attitude towards personal competency to prevent pressure ulcers (three items); (2) attitude towards the priority of pressure ulcer prevention (three items); (3) attitude towards the impact of pressure ulcers (three items); (4) attitude towards personal responsibility in pressure ulcer prevention (two items); and (5) attitude towards confidence in the effectiveness of prevention (two items). This five factor solution accounted for 61.4% of the variance in responses related to attitudes towards pressure ulcer prevention. All items demonstrated factor loadings over 0.60. The instrument produced similar results during stability testing [ICC=0.88 (95% CI=0.84-0.91, P<0.001)]. For the total instrument, the internal consistency (Cronbachs alpha) was 0.79. The APuP is a psychometrically sound instrument that can be used to effectively assess attitudes towards pressure ulcer prevention in patient care, education, and research. In further research, the association between attitude, knowledge and clinical performance should be explored. Copyright 2010 Elsevier Ltd. All rights reserved.

  5. Sampling the Soils around a Residence Containing Lead-Based Paints: An X-Ray Fluorescence Experiment

    ERIC Educational Resources Information Center

    Bachofer, Steven J.

    2008-01-01

    Sampling experiments utilizing field portable instruments are instructional since students collect data following regulatory protocols, evaluate it, and begin to recognize their civic responsibilities upon collecting useful data. A lead-in-soil experiment educated students on a prevalent exposure pathway. The experimental site was a pre-1950…

  6. Comparing conventional Descriptive Analysis and Napping®-UFP against physiochemical measurements: a case study using apples.

    PubMed

    Pickup, William; Bremer, Phil; Peng, Mei

    2018-03-01

    The extensive time and cost associated with conventional sensory profiling methods has spurred sensory researchers to develop rapid method alternatives, such as Napping® with Ultra-Flash Profiling (UFP). Napping®-UFP generates sensory maps by requiring untrained panellists to separate samples based on perceived sensory similarities. Evaluations of this method have been restrained to manufactured/formulated food models, and predominantly structured on comparisons against the conventional descriptive method. The present study aims to extend the validation of Napping®-UFP (N = 72) to natural biological products; and to evaluate this method against Descriptive Analysis (DA; N = 8) with physiochemical measurements as an additional evaluative criterion. The results revealed that sample configurations generated by DA and Napping®-UFP were not significantly correlated (RV = 0.425, P = 0.077); however, they were both correlated with the product map generated based on the instrumental measures (P < 0.05). The finding also noted that sample characterisations from DA and Napping®-UFP were driven by different sensory attributes, indicating potential structural differences between these two methods in configuring samples. Overall, these findings lent support for the extended use of Napping®-UFP for evaluations of natural biological products. Although DA was shown to be a better method for establishing sensory-instrumental relationships, Napping®-UFP exhibited strengths in generating informative sample configurations based on holistic perception of products. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  7. An instrument to assess the statistical intensity of medical research papers.

    PubMed

    Nieminen, Pentti; Virtanen, Jorma I; Vähänikkilä, Hannu

    2017-01-01

    There is widespread evidence that statistical methods play an important role in original research articles, especially in medical research. The evaluation of statistical methods and reporting in journals suffers from a lack of standardized methods for assessing the use of statistics. The objective of this study was to develop and evaluate an instrument to assess the statistical intensity in research articles in a standardized way. A checklist-type measure scale was developed by selecting and refining items from previous reports about the statistical contents of medical journal articles and from published guidelines for statistical reporting. A total of 840 original medical research articles that were published between 2007-2015 in 16 journals were evaluated to test the scoring instrument. The total sum of all items was used to assess the intensity between sub-fields and journals. Inter-rater agreement was examined using a random sample of 40 articles. Four raters read and evaluated the selected articles using the developed instrument. The scale consisted of 66 items. The total summary score adequately discriminated between research articles according to their study design characteristics. The new instrument could also discriminate between journals according to their statistical intensity. The inter-observer agreement measured by the ICC was 0.88 between all four raters. Individual item analysis showed very high agreement between the rater pairs, the percentage agreement ranged from 91.7% to 95.2%. A reliable and applicable instrument for evaluating the statistical intensity in research papers was developed. It is a helpful tool for comparing the statistical intensity between sub-fields and journals. The novel instrument may be applied in manuscript peer review to identify papers in need of additional statistical review.

  8. Wavelength Scanning with a Tilting Interference Filter for Glow-Discharge Elemental Imaging.

    PubMed

    Storey, Andrew P; Ray, Steven J; Hoffmann, Volker; Voronov, Maxim; Engelhard, Carsten; Buscher, Wolfgang; Hieftje, Gary M

    2017-06-01

    Glow discharges have long been used for depth profiling and bulk analysis of solid samples. In addition, over the past decade, several methods of obtaining lateral surface elemental distributions have been introduced, each with its own strengths and weaknesses. Challenges for each of these techniques are acceptable optical throughput and added instrumental complexity. Here, these problems are addressed with a tilting-filter instrument. A pulsed glow discharge is coupled to an optical system comprising an adjustable-angle tilting filter, collimating and imaging lenses, and a gated, intensified charge-coupled device (CCD) camera, which together provide surface elemental mapping of solid samples. The tilting-filter spectrometer is instrumentally simpler, produces less image distortion, and achieves higher optical throughput than a monochromator-based instrument, but has a much more limited tunable spectral range and poorer spectral resolution. As a result, the tilting-filter spectrometer is limited to single-element or two-element determinations, and only when the target spectral lines fall within an appropriate spectral range and can be spectrally discerned. Spectral interferences that result from heterogeneous impurities can be flagged and overcome by observing the spatially resolved signal response across the available tunable spectral range. The instrument has been characterized and evaluated for the spatially resolved analysis of glow-discharge emission from selected but representative samples.

  9. Peak exposures in aluminium potrooms: instrument development and field calibration.

    PubMed

    Carter, Stephanie R; Seixas, Noah S; Thompson, Mary Lou; Yost, Michael G

    2004-11-01

    Aluminium smelter potrooms are unique in that workplace exposures to hydrogen fluoride (HF), sulfur dioxide (SO2), and particulate matter occur simultaneously for some tasks. The peak exposures to these contaminants are of increasing interest in discovering the etiology of respiratory health effects. While a variety of direct-reading instruments are available for sulfur dioxide and particulate matter, only a few exist for hydrogen fluoride. The sensors in these HF instruments have a cross-sensitivity to sulfur dioxide making it difficult to monitor HF in an environment that also contains SO2. To overcome this problem, we assessed the simultaneous use of two electrochemical instruments: one with a SO2 sensor that does not respond to HF and the second with a hydrogen fluoride sensor that responds to both HF and SO2 in a 1 : 1 ratio, termed 'total acid gas'. The difference in the response between the two instruments should indicate the HF concentration: [HF + SO2] minus SO2 equals HF. The performance characteristics of this sampling train were evaluated in the laboratory through the generation of both HF and SO2 with permeation tubes. The response and recovery times for the SO2 only instrument were acceptable (6 and 15 s, respectively), but the "total acid gas" instrument exhibited both slow response and slow recovery approaching three and six min. The association between the traditional integrated filter sampling method and the direct-reading instrument for SO2 is 0.80 (Spearman's rho). The use of the digital filter strengthens the association between the HF direct-reading instrument and the integrated samples from 0.41 to 0.68.

  10. Robust inference in summary data Mendelian randomization via the zero modal pleiotropy assumption.

    PubMed

    Hartwig, Fernando Pires; Davey Smith, George; Bowden, Jack

    2017-12-01

    Mendelian randomization (MR) is being increasingly used to strengthen causal inference in observational studies. Availability of summary data of genetic associations for a variety of phenotypes from large genome-wide association studies (GWAS) allows straightforward application of MR using summary data methods, typically in a two-sample design. In addition to the conventional inverse variance weighting (IVW) method, recently developed summary data MR methods, such as the MR-Egger and weighted median approaches, allow a relaxation of the instrumental variable assumptions. Here, a new method - the mode-based estimate (MBE) - is proposed to obtain a single causal effect estimate from multiple genetic instruments. The MBE is consistent when the largest number of similar (identical in infinite samples) individual-instrument causal effect estimates comes from valid instruments, even if the majority of instruments are invalid. We evaluate the performance of the method in simulations designed to mimic the two-sample summary data setting, and demonstrate its use by investigating the causal effect of plasma lipid fractions and urate levels on coronary heart disease risk. The MBE presented less bias and lower type-I error rates than other methods under the null in many situations. Its power to detect a causal effect was smaller compared with the IVW and weighted median methods, but was larger than that of MR-Egger regression, with sample size requirements typically smaller than those available from GWAS consortia. The MBE relaxes the instrumental variable assumptions, and should be used in combination with other approaches in sensitivity analyses. © The Author 2017. Published by Oxford University Press on behalf of the International Epidemiological Association

  11. ELIMINATION OF INTRACANAL INFECTION IN DOGS' TEETH WITH INDUCED PERIAPICAL LESIONS AFTER ROTARY INSTRUMENTATION: INFLUENCE OF DIFFERENT CALCIUM HYDROXIDE PASTES

    PubMed Central

    Soares, Janir Alves; Leonardo, Mário Roberto; da Silva, Léa Assed Bezerra; Tanomaru, Mário; Ito, Izabel Yoko

    2006-01-01

    The aim of this study was to evaluate the antiseptic efficacy of rotary instrumentation associated with calcium hydroxide-based pastes prepared with different vehicles and antiseptics. Chronic periapical lesions were experimentally induced in 72 premolar root canals of four dogs. Under controlled asepsis, after initial microbiological sampling (A1), the root canals were instrumented using the ProFile system in conjunction with 5.25% sodium hypochlorite and the intracanal medication was placed. Four experimental groups were formed according to the pastes used: group 1- Calen (n=18), group 2- Calen+CPMC (n=20), group 3- Ca(OH)2 p.a.+ anaesthetic solution (n=16) and group 4- Ca(OH)2 p.a.+ 2% chlorhexidine digluconate (n=18). After 21 days, the pastes were removed; the canals were emptied and 96 hours later a second microbiological sample was obtained (A2). The incidence of positive microbiological cultures and the number of cfus in stages A1 and A2 were compared statistically by the Wilcoxon test while the influence of the different treatments in intracanal infection was evaluated by Kruskal-Wallis test at 5% significance level (p<0.05). Large numbers of strict and facultative anaerobes, and viridans group streptococci were found in 100% of root canals of A1 samples. Among A2 samples, all treatments showed significant reduction of cfus and positive cultures (p<0.05), but only groups 3 and 4 showed 100% of root canals free of microorganisms. Rotary instrumentation plus NaOCl 5.25% associated with intracanal medication produced a drastic reduction or elimination of intracanal microbiota, whose performance was not influenced by the nature of the vehicle or the antiseptic added to the Ca(OH)2 p.a. PMID:19089068

  12. [Scanning electron microscopy investigation of canal cleaning after canal preparation with nickel titanium files].

    PubMed

    Brkanić, Tatjana; Ivana, Stojsin; Vukoje, Karolina; Zivković, Slavoljub

    2010-01-01

    Root canal preparation is the most important phase of endodontic procedure and it consists of adequate canal space cleaning and shaping. In recent years, rotary instruments and techniques have gained importance because of the great efficacy, speed and safety of the preparation procedure. The aim of this research was to investigate the influence of different NiTi files on the canal wall cleaning quality, residual dentine debris and smear layer. The research was conducted on extracted human teeth in vitro conditions. Teeth were divided in 7 main groups depending on the kind of instruments used for root canal preparation: ProTaper, GT, ProFile, K-3, FlexMaster, hand ProTaper and hand GT. Root canal preparation was accomplished by crown-down technique. Prepared samples were assessed on scanning electron microscopy JEOL, JSM-6460 LV. The evaluation of dentine debris was done with 500x magnification, and the evaluation of smear layer with 1,000 times magnification. Quantitive assessment of dentine debris and smear layer was done according to the criteria of Hulsmann. The least amount of debris and smear layer has been found in canals shaped with ProFile instruments, and the largest amount in canals shaped with FlexMaster instruments. Canal cleaning efficacy of hand GTand ProTaperfiles has been similar to cleaning efficacy of rotary NiTi files. Statistic analysis has shown a significant difference in amount of dentine debris and smear layer on the canal walls between sample groups. shaped with different instruments. Completely clean canals have not been found in any tested group of instruments. The largest amount of debris and smear layer has been found in the apical third of all canals. The design and the type of endodontic instruments influence the efficacy of the canal cleaning.

  13. Brief Report: Development of the Family Perceptions Scale; a Novel Instrument for Evaluating Subjective Functioning in the Families of Adolescents

    ERIC Educational Resources Information Center

    Tiffin, Paul A.; Kaplan, Carole; Place, Maurice

    2011-01-01

    A pool of 75 items relating to family functioning was created and piloted in a sample of 12-18 year olds (N = 673). The responses were subjected to an exploratory factor analysis which indicated the presence of three significant latent traits. The results were then used to inform the development of a rating instrument with five subscales labelled…

  14. Exploring the applicability and limitations of selected optical scattering instruments for PM mass measurement

    NASA Astrophysics Data System (ADS)

    Zhang, Jie; Marto, Joseph P.; Schwab, James J.

    2018-05-01

    Two optical scattering instruments for particle mass measurement, the Thermo Personal Data RAM (PDR-1500) and the TSI Environmental DustTrak DRX (Model 8543) were evaluated by (1) using poly- and mono-disperse test aerosol in the laboratory, and (2) sampling ambient aerosol. The responses of these optical scattering instruments to different particle characteristics (size, composition, concentration) were compared with responses from reference instruments. A Mie scattering calculation was used to explain the dependence of the optical instruments' response to aerosol size and composition. Concurrently, the detection efficiency of one Alphasense Optical Particle Counter (OPC-N2) was evaluated in the laboratory as well. The relationship between aerosol mass concentration and optical scattering was determined to be strongly dependent on aerosol size and to a lesser extent on aerosol composition (as reflected in the refractive indices of the materials tested) based on ambient measurements. This confirms that there is no simple way to use optical scattering instruments over a wide range of conditions without adjustments based on knowledge of aerosol size and composition. In particular, a test period measuring ambient aerosol with optical scattering instruments and a mass based method (an Aerodyne Aerosol Mass Spectrometer) determined that roughly two thirds of the variance (R2 = 0.64) of the optical to mass signal ratio is explained by the aerosol mass median diameter alone. These observations and calculations help evaluate the applicability and limitations of these optical scattering instruments, and provide guidance to designing suitable applications for each instrument by considering aerosol sources and aerosol size.

  15. A comparative evaluation of two rotary Ni-Ti instruments in the removal of gutta-percha during retreatment

    PubMed Central

    Preetam, C. S.; Chandrashekhar, M.; Gunaranjan, T.; Kumar, S. Kishore; Miskeen Sahib, S. A.; Kumar, M. Senthil

    2016-01-01

    Aim: The purpose of this study is to achieve an effective method to remove root canal filling material from the root canal system. The study, thus, aims to evaluate the efficacy of the cleaning ability of two different rotary Ni-Ti systems; ProTaper Retreatment files and RaCe System compared to hand instrumentation with Hedstrom files for the removal of gutta-percha during retreatment. Materials and Methods: Thirty mandibular premolars with one single straight canal were decoronated and instrumented with ProTaper files and filled with thermoplastic gutta-percha. After 30 days, the samples were divided into three groups and gutta-percha was removed with the test instruments. The postoperative radiographs were evaluated with known criteria by dividing the root into cervical third, middle third, and apical third. The results were tabulated and Statistical Package for Social Sciences Software (IBM Corporation) was used for analysis. Results: The mean deviation of the results were first calculated and then t-test and analysis of variance test (two-tailed P value) were evaluated for establishing significant differences. The rotary instruments were effective in removing the gutta-percha from the canals. Therefore, significant difference was observed between the efficacies of the two rotary systems used. The rotary instruments showed effective gutta-percha removal in the cervical and middle one third. (P > 0.05). However, apical debridement was effective with Hedstrom files. Conclusion: The study concluded the use of both rotary and hand instrumentation for effective removal of gutta-percha for retreatment. PMID:27652245

  16. Development and evaluation of an instrument to measure parental satisfaction with quality of care in neonatal follow-up.

    PubMed

    Butt, Michelle L; Pinelli, Janet; Boyle, Michael H; Thomas, Helen; Hunsberger, Mabel; Saigal, Saroj; Lee, David S; Fanning, Jamie K; Austin, Patricia

    2009-02-01

    The goal of this study was to develop and subsequently evaluate the psychometric properties of a new discriminative instrument to measure parental satisfaction with the quality of care provided in neonatal follow-up (NFU) programs. The methodological framework for developing and evaluating measurement scales described by Streiner and Norman (Health Measurement Scales: A Practical Guide to Their Development and Use. 3rd ed. New York: Oxford University Press; 2003) was used for the study. Informing the phases of the research was a sample of 24 health care professionals and 381 parents who use NFU services. A comprehensive list of items representing the construct, parental satisfaction with quality of care, was generated from published reliable and valid instruments, research studies, focus groups with health care experts, and focus groups with parents. Using a clinimetric approach, the 62 items generated were reduced to 39 items based on parents' ratings of importance and refinement of the items by the research team. After content validation and pretesting, the instrument was tested with parents and underwent item-analysis. The resulting 16-item instrument was composed of 2 subscales, Process and Outcomes. Evaluation of the instrument's psychometric properties indicated adequate test-retest reliability (intraclass correlation coefficient = 0.72) and internal consistency (Process subscale, alpha = 0.77; Outcomes subscale, alpha = 0.90; overall instrument, alpha = 0.90), as well as good content and construct validity. A confirmatory factor analysis supported the multidimensionality of the construct. This new instrument provides clinicians and policy-makers with a tool to assess parental satisfaction with the quality of care in NFU, so areas of dissatisfaction can be identified and changes implemented to optimize service provision.

  17. Prediction of future falls in a community dwelling older adult population using instrumented balance and gait analysis.

    PubMed

    Bauer, C M; Gröger, I; Rupprecht, R; Marcar, V L; Gaßmann, K G

    2016-04-01

    The role of instrumented balance and gait assessment when screening for prospective fallers is currently a topic of controversial discussion. This study analyzed the association between variables derived from static posturography, instrumented gait analysis and clinical assessments with the occurrence of prospective falls in a sample of community dwelling older people. In this study 84 older people were analyzed. Based on a prospective occurrence of falls, participants were categorized into fallers and non-fallers. Variables derived from clinical assessments, static posturography and instrumented gait analysis were evaluated with respect to the association with the occurrence of prospective falls using a forward stepwise, binary, logistic regression procedure. Fallers displayed a significantly shorter single support time during walking while counting backwards, increased mediolateral to anteroposterior sway amplitude ratio, increased fast mediolateral oscillations and a larger coefficient (Coeff) of sway direction during various static posturography tests. Previous falls were insignificantly associated with the occurrence of prospective falls. Variables derived from posturography and instrumented gait analysis showed significant associations with the occurrence of prospective falls in a sample of community dwelling older adults.

  18. Psychometric Validation of the Parental Bonding Instrument in a U.K. Population-Based Sample: Role of Gender and Association With Mental Health in Mid-Late Life.

    PubMed

    Xu, Man K; Morin, Alexandre J S; Marsh, Herbert W; Richards, Marcus; Jones, Peter B

    2016-08-01

    The factorial structure of the Parental Bonding Instrument (PBI) has been frequently studied in diverse samples but no study has examined its psychometric properties from large, population-based samples. In particular, important questions have not been addressed such as the measurement invariance properties across parental and offspring gender. We evaluated the PBI based on responses from a large, representative population-based sample, using an exploratory structural equation modeling method appropriate for categorical data. Analysis revealed a three-factor structure representing "care," "overprotection," and "autonomy" parenting styles. In terms of psychometric measurement validity, our results supported the complete invariance of the PBI ratings across sons and daughters for their mothers and fathers. The PBI ratings were also robust in relation to personality and mental health status. In terms of predictive value, paternal care showed a protective effect on mental health at age 43 in sons. The PBI is a sound instrument for capturing perceived parenting styles, and is predictive of mental health in middle adulthood. © The Author(s) 2016.

  19. Instruments for measuring mental health recovery: a systematic review.

    PubMed

    Sklar, Marisa; Groessl, Erik J; O'Connell, Maria; Davidson, Larry; Aarons, Gregory A

    2013-12-01

    Persons in recovery, providers, and policymakers alike are advocating for recovery-oriented mental health care, with the promotion of recovery becoming a prominent feature of mental health policy in the United States and internationally. One step toward creating a recovery-oriented system of care is to use recovery-oriented outcome measures. Numerous instruments have been developed to assess progress towards mental health recovery. This review identifies instruments of mental health recovery and evaluates the appropriateness of their use including their psychometric properties, ease of administration, and service-user involvement in their development. A literature search using the Medline and Psych-INFO databases was conducted, identifying 21 instruments for potential inclusion in this review, of which thirteen met inclusion criteria. Results suggest only three instruments (25%) have had their psychometric properties assessed in three or more unique samples of participants. Ease of administration varied between instruments, and for the majority of instruments, development included service user involvement. This review updates and expands previous reviews of instruments to assess mental health recovery. As mental health care continues to transform to a recovery-oriented model of service delivery, this review may facilitate selection of appropriate assessments of mental health recovery for systems to use in evaluating and improving the care they provide. © 2013.

  20. [A survey instrument for evaluating psychological variables and risky sexual behavior among young adults at two university centers in Mexico].

    PubMed

    Piña López, Julio A; Robles Montijo, Susana; Rivera Icedo, Blanca M

    2007-11-01

    To measure the psychometric attributes of a survey instrument designed to evaluate historical and context variables that lead to high-risk sexual behaviors among a sample of university students in Mexico. Cross-sectional study of a sample of 1 346 university students in Mexico: 784 from the Sonora State Center for Higher Education in Hermosillo, Sonora, or 33.2% of its total enrollment; and 562 from the National Autonomous University of Mexico, at Tlalnepantla campus in Mexico State, or 23.5% of its total enrollment. The study took place in Hermosillo during the month of October 2006 and in Tlalnepantla from January to March 2006. The survey had 11 questions on sociodemographics, 7 on risky sexual behaviors, 22 on related motives, 8 on social context, and 6 on physical status prior to sexual relations. The survey was evaluated in terms of how well the questions were understood, its conceptual validity, and reliability. The final version of the survey instrument was composed of 44 questions. The reliability analysis produced an overall Cronbach alpha value of 0.821, taking into account all the variables combined and grouped by factor. Three factors were found that together accounted for 38.36% of the total variance: reasons for not using a condom in the first sexual relationship or throughout life, reasons for inconsistent use of a condom with a casual sex partner, and willingness to become sexually active and to engage in casual sex. The psychometric attributes of this survey instrument were found to be satisfactory. Those interested in using this instrument should become familiar with the theoretical model on which it is based, since understanding the results depends on properly defining the historical and context variables, and their interaction.

  1. Noble Gas Analysis for Mars Robotic Missions: Evaluating K-Ar Age Dating for Mars Rock Analogs and Martian Shergottites

    NASA Technical Reports Server (NTRS)

    Park, J.; Ming, D. W.; Garrison, D. H.; Jones, J. H.; Bogard, D. D.; Nagao, K.

    2009-01-01

    The purpose of this noble gas investigation was to evaluate the possibility of measuring noble gases in martian rocks and air by future robotic missions such as the Mars Science Laboratory (MSL). The MSL mission has, as part of its payload, the Sample Analysis at Mars (SAM) instrument, which consists of a pyrolysis oven integrated with a GCMS. The MSL SAM instrument has the capability to measure noble gas compositions of martian rocks and atmosphere. Here we suggest the possibility of K-Ar age dating based on noble gas release of martian rocks by conducting laboratory simulation experiments on terrestrial basalts and martian meteorites. We provide requirements for the SAM instrument to obtain adequate noble gas abundances and compositions within the current SAM instrumental operating conditions, especially, a power limit that prevents heating the furnace above approx.1100 C. In addition, Martian meteorite analyses from NASA-JSC will be used as ground truth to evaluate the feasibility of robotic experiments to constrain the ages of martian surface rocks.

  2. Development and psychometric evaluation of the Primary Health Care Engagement (PHCE) Scale: a pilot survey of rural and remote nurses.

    PubMed

    Kosteniuk, Julie G; Wilson, Erin C; Penz, Kelly L; MacLeod, Martha L P; Stewart, Norma J; Kulig, Judith C; Karunanayake, Chandima P; Kilpatrick, Kelley

    2016-01-01

    To report the development and psychometric evaluation of a scale to measure rural and remote (rural/remote) nurses' perceptions of the engagement of their workplaces in key dimensions of primary health care (PHC). Amidst ongoing PHC reforms, a comprehensive instrument is needed to evaluate the degree to which rural/remote health care settings are involved in the key dimensions that characterize PHC delivery, particularly from the perspective of professionals delivering care. This study followed a three-phase process of instrument development and psychometric evaluation. A literature review and expert consultation informed instrument development in the first phase, followed by an iterative process of content evaluation in the second phase. In the final phase, a pilot survey was undertaken and item discrimination analysis employed to evaluate the internal consistency reliability of each subscale in the preliminary 60-item Primary Health Care Engagement (PHCE) Scale. The 60-item scale was subsequently refined to a 40-item instrument. The pilot survey sample included 89 nurses in current practice who had experience in rural/remote practice settings. Participants completed either a web-based or paper survey from September to December, 2013. Following item discrimination analysis, the 60-item instrument was refined to a 40-item PHCE Scale consisting of 10 subscales, each including three to five items. Alpha estimates of the 10 refined subscales ranged from 0.61 to 0.83, with seven of the subscales demonstrating acceptable reliability (α ⩾ 0.70). The refined 40-item instrument exhibited good internal consistency reliability (α=0.91). The 40-item PHCE Scale may be considered for use in future studies regardless of locale, to measure the extent to which health care professionals perceive their workplaces to be engaged in key dimensions of PHC.

  3. Psychometric Evaluation of the D-Catch, an Instrument to Measure the Accuracy of Nursing Documentation.

    PubMed

    D'Agostino, Fabio; Barbaranelli, Claudio; Paans, Wolter; Belsito, Romina; Juarez Vela, Raul; Alvaro, Rosaria; Vellone, Ercole

    2017-07-01

    To evaluate the psychometric properties of the D-Catch instrument. A cross-sectional methodological study. Validity and reliability were estimated with confirmatory factor analysis (CFA) and internal consistency and inter-rater reliability, respectively. A sample of 250 nursing documentations was selected. CFA showed the adequacy of a 1-factor model (chronologically descriptive accuracy) with an outlier item (nursing diagnosis accuracy). Internal consistency and inter-rater reliability were adequate. The D-Catch is a valid and reliable instrument for measuring the accuracy of nursing documentation. Caution is needed when measuring diagnostic accuracy since only one item measures this dimension. The D-Catch can be used as an indicator of the accuracy of nursing documentation and the quality of nursing care. © 2015 NANDA International, Inc.

  4. The Development of an Instrument to Measure the Project Competences of College Students in Online Project-Based Learning

    NASA Astrophysics Data System (ADS)

    Lin, Chien-Liang

    2018-02-01

    This study sought to develop a self-report instrument to be used in the assessment of the project competences of college students engaged in online project-based learning. Three scales of the KIPSSE instrument developed for this study, namely, the knowledge integration, project skills, and self-efficacy scales, were based on related theories and the analysis results of three project advisor interviews. Those items of knowledge integration and project skill scales focused on the integration of different disciplines and technological skills separately. Two samples of data were collected from information technology-related courses taught with an online project-based learning strategy over different semesters at a college in southern Taiwan. The validity and reliability of the KIPSSE instrument were confirmed through item analysis and confirmatory factor analysis using structural equation modeling of two samples of students' online response sets separately. The Cronbach's alpha reliability coefficient for the entire instrument was 0.931; for each scale, the alpha ranged from 0.832 to 0.907. There was also a significant correlation ( r = 0.55, p < 0.01) between the KIPSSE instrument results and the students' product evaluation scores. The findings of this study confirmed the validity and reliability of the KIPSSE instrument. The confirmation process and related implications are also discussed.

  5. Measurement Issues: Screening and diagnostic instruments for autism spectrum disorders – lessons from research and practice

    PubMed Central

    Charman, Tony; Gotham, Katherine

    2012-01-01

    Background and Scope Significant progress has been made over the past two decades in the development of screening and diagnostic instruments for autism spectrum disorders (ASD). This article reviews this progress, including recent innovations, focussing on those instruments for which the strongest research data on validity exists, and then turns to addressing issues arising from their use in clinical settings. Findings Research studies have evaluated the ability of screens to prospectively identify cases of ASD in population-based and clinically-referred samples, as well as the accuracy of diagnostic instruments to map onto ‘gold standard’ clinical best estimate diagnosis. However, extension of the findings to clinical services must be done with caution, with a full understanding that instrument properties are sample-specific. Furthermore, we are limited by the lack of a true test for ASD, which remains a behaviourally-defined disorder. In addition screening and diagnostic instruments help clinicians least in the cases where they are most in want of direction, since their accuracy will always be lower for marginal cases. Conclusion Instruments help clinicians to collect detailed, structured information and increase accuracy and reliability of referral for in-depth assessment and recommendations for support, but further research is needed to refine their effective use in clinical settings. PMID:23539140

  6. A comparison of two computer-automated semen analysis instruments for the evaluation of sperm motion characteristics in the stallion.

    PubMed

    Jasko, D J; Lein, D H; Foote, R H

    1990-01-01

    Two commercially available computer-automate semen analysis instruments (CellSoft Automated Semen Analyzer and HTM-2000 Motion Analyzer) were compared for their ability to report similar results based on the analysis of pre-recorded video tapes of extended, motile stallion semen. The determinations of the percentage of motile cells by these instruments were more similar than the comparisons between subjective estimates and either instrument. However, mean values obtained from the same sample may still differ by as much as 30 percentage units between instruments. Instruments varied with regard to the determinations of mean sperm curvilinear velocity and sperm concentration, but mean sperm linearity determinations were similar between the instruments. We concluded that the determinations of sperm motion characteristics by subjective estimation, CellSoft Automated Semen Analyzer, and HTM-2000 Motility Analyzer are often dissimilar, making direct comparisons of results difficult.

  7. Determination of Root Canal Cleanliness by Different Irrigation Methods and Morphometric Analysis of Apical Third.

    PubMed

    Seixas, Fábio Heredia; Estrela, Carlos; Bueno, Mike Reis; Sousa-Neto, Manoel Damião; Pécora, Jesus Djalma

    2015-06-01

    The aim of this study was to determine the root canal area before and after the instrumentation 1 mm short of the apical foramen by clinical and cone beam computed tomography (CBCT) methods, and to evaluate the cleanliness of the apical region in mesiodistal flattened teeth by using optical microscopy. Forty-two human single-canal mandibular incisors were instrumented using the Free Tip Preparation technique up to three, four or five instruments from the initial. Cone beam computed tomography scans were acquired of the samples before and after root canal preparation (RCP). Irrigation was performed by conventional or hydrodynamic means, using 2.5% sodium hypochlorite. The samples were prepared for observation under an optical microscope. Images were digitally obtained, analyzed and the results were submitted to statistical analysis (two-way ANOVA complemented by Bonferroni's post-test). There was no significant difference between the studied anatomical areas with both CBCT and clinical methods. There were no differences between irrigation methods. It was verified differences between instrumentation techniques. Instrumentation with four instruments from the initial instrument determined a significant increase in the contact area when compared to preparation with three instruments, but RCP with 5 instruments did not result in a better cleanliness. The analysis with CBCT was not capable to determine the precise shape of surgical apical area comparing to the clinical method. Both the conventional and hydrodynamic irrigation techniques were not able to promote root canals debris-free. The instruments action in root canal walls was proportional to the number of instruments used from the initial apical instrument.

  8. Teacher Evaluation: Practices and Procedures. ERS Report.

    ERIC Educational Resources Information Center

    Educational Research Service, Arlington, VA.

    This report presents findings of the 1988 Educational Research Service survey of teacher evaluation practices and procedures in U.S. schools. The survey instrument was mailed to a random sample of 1,730 superintendents of school districts of varying size. The response rate was 52.5 percent. The first section discusses the purposes of teacher…

  9. Evaluating Quality in Associate Degree Culinary Arts Programs

    ERIC Educational Resources Information Center

    Hertzman, Jean; Ackerman, Robert

    2010-01-01

    Purpose: The purpose of this study is to determine which categories and indicators of quality are best suited to evaluating associate degree culinary arts programs (ADCAP). Design/methodology/approach: The researchers surveyed a national sample of culinary educators and industry chefs in the USA. The instrument asked the participants to rate the…

  10. Comparison of three instruments for measuring patient anxiety in a coronary care unit.

    PubMed

    Elliott, D

    1993-09-01

    This paper compares the State-Trait Anxiety Inventory (STAI), Hospital Anxiety and Depression Scale (HAD Scale) and a Linear Analogue Anxiety Scale (LAAS) for evaluating anxiety in patients with acute ischaemic heart disease. The instruments were examined for correlation, reliability and internal consistency. Strong associations were demonstrated at pre-test between the STAI and the other scales. Moderate coefficients between HAD-A and HAD-D/LAAS were also apparent. Lower correlations were found at post-test than at pre-test. At post-test, strong inter-correlations occurred for STAI/LAAS. The HAD Scale demonstrated high test-retest reliability, while the STAI and LAAS were moderate in their reliability in this sample. The adequate correlation between the instruments suggest that each is a valid and appropriate measure of anxiety in this clinical sample.

  11. 77 FR 52319 - Notice of Proposed Information Collection Requests; Institute of Education Sciences; Needs...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-29

    ... research and evaluation needs in the future. The results of the survey will be used to prioritize the... Sciences; Needs Sensing Survey Under the REL Program: Sample Survey Instrument for School Board Members and District Administrators SUMMARY: The needs assessment consists of an online survey of a sample of school...

  12. Mechanical reduction of the intracanal Enterococcus faecalis population by Hyflex CM, K3XF, ProTaper Next, and two manual instrument systems: an in vitro comparative study.

    PubMed

    Tewari, Rajendra K; Ali, Sajid; Mishra, Surendra K; Kumar, Ashok; Andrabi, Syed Mukhtar-Un-Nisar; Zoya, Asma; Alam, Sharique

    2016-05-01

    In the present study, the effectiveness of three rotary and two manual nickel titanium instrument systems on mechanical reduction of the intracanal Enterococcus faecalis population was evaluated. Mandibular premolars with straight roots were selected. Teeth were decoronated and instrumented until 20 K file and irrigated with physiological saline. After sterilization by ethylene oxide gas, root canals were inoculated with Enterococcus faecalis. The specimens were randomly divided into five groups for canal instrumentation: Manual Nitiflex and Hero Shaper nickel titanium files, and rotary Hyflex CM, ProTaper Next, and K3XF nickel titanium files. Intracanal bacterial sampling was done before and after instrumentation. After serial dilution, samples were plated onto the Mitis Salivarius agar. The c.f.u. grown were counted, and log10 transformation was calculated. All instrumentation systems significantly reduced the intracanal bacterial population after root canal preparation. ProTaper Next was found to be significantly more effective than Hyflex CM and manual Nitiflex and Hero Shaper. However, ProTaper Next showed no significant difference with K3XF. Canal instrumentation by all the file systems significantly reduced the intracanal Enterococcus faecalis counts. ProTaper Next was found to be most effective in reducing the number of bacteria than other rotary or hand instruments. © 2014 Wiley Publishing Asia Pty Ltd.

  13. An evaluation of general practice websites in the UK.

    PubMed

    Howitt, Alistair; Clement, Sarah; de Lusignan, Simon; Thiru, Krish; Goodwin, Daryl; Wells, Sally

    2002-10-01

    General practice websites are an emerging phenomenon, but there have been few critical evaluations of their content. Previously developed rating instruments to assess medical websites have been criticized for failing to report their reliability and validity. The purpose of this study was to develop a rating instrument for assessing UK general practice websites, and then to evaluate them critically. The STaRNet Website Assessment Tool (SWAT) was developed listing criteria that general practice websites may meet, which was then used to evaluate a random sample of websites drawn from an electronic database. A second assessor rated a subsample of the sites to assess the tool's inter-rater reliability. The setting was an information technology group of a general practice research network using a random sample of 108 websites identified from the database. The main outcome measures were identification of rating criteria and frequency counts from the website rating instrument. Ninety (93.3%) sites were accessible, of which 84 were UK general practice websites. Criteria most frequently met were those describing the scope of the website and their functionality. Apart from e-mail to practices, criteria related to electronic communication were rarely met. Criteria relating to the quality of information were least often met. Inter-rater reliability kappa values for the items in the tool ranged from -0.06 to 1.0 (mean 0.59). Values were >0.6 for 15 out of 25 criteria assessed in 40 sites which were rated by two assessors. General practice websites offer a wide range of information. They are technically satisfactory, but do not exploit fully the potential for electronic doctor-patient communication. The quality of information they provide is poor. The instrument may be developed as a template for general practices producing or revising their own websites.

  14. Systematic comparison of static and dynamic headspace sampling techniques for gas chromatography.

    PubMed

    Kremser, Andreas; Jochmann, Maik A; Schmidt, Torsten C

    2016-09-01

    Six automated, headspace-based sample preparation techniques were used to extract volatile analytes from water with the goal of establishing a systematic comparison between commonly available instrumental alternatives. To that end, these six techniques were used in conjunction with the same gas chromatography instrument for analysis of a common set of volatile organic carbon (VOC) analytes. The methods were thereby divided into three classes: static sampling (by syringe or loop), static enrichment (SPME and PAL SPME Arrow), and dynamic enrichment (ITEX and trap sampling). For PAL SPME Arrow, different sorption phase materials were also included in the evaluation. To enable an effective comparison, method detection limits (MDLs), relative standard deviations (RSDs), and extraction yields were determined and are discussed for all techniques. While static sampling techniques exhibited sufficient extraction yields (approx. 10-20 %) to be reliably used down to approx. 100 ng L(-1), enrichment techniques displayed extraction yields of up to 80 %, resulting in MDLs down to the picogram per liter range. RSDs for all techniques were below 27 %. The choice on one of the different instrumental modes of operation (aforementioned classes) was thereby the most influential parameter in terms of extraction yields and MDLs. Individual methods inside each class showed smaller deviations, and the least influences were observed when evaluating different sorption phase materials for the individual enrichment techniques. The option of selecting specialized sorption phase materials may, however, be more important when analyzing analytes with different properties such as high polarity or the capability of specific molecular interactions. Graphical Abstract PAL SPME Arrow during the extraction of volatile analytes from the headspace of an aqueous sample.

  15. Descriptive analysis of the Test of Everyday Attention for Children in a Spanish Normative Sample.

    PubMed

    Pardos, Alexandra; Quintero, Javier; Zuluaga, Pilar; Fernández, Alberto

    2016-09-01

    Test of Everyday Attention for Children (TEA-Ch) has been validated in different countries demonstrating that it is an instrument with a correct balance between reliability and duration. Given the shortage of trustworthy instruments of evaluation in our language for infantile population we decide to explore the Spanish version of the TEA-Ch. We administered TEA-Ch (version A) to a sample control of 133 Spanish children from 6 to 11 years enrolled in school in the Community of Madrid. Four children were selected at random by course of Primary Education, distributing the sex of equivalent form. Descriptive analysis and comparison by ages and sex in each of the TEA-Ch´s subtests were conducted to establish a profile of the sample. In order to analyze the effect of the age, subjects were grouped in six sub-samples: 6, 7, 8, 9, 10 and 11 years-old. This first descriptive analysis demonstrates age exerted a significant effect on each measure, due to an important “jump” in children´s performance between 6 and 7 years-old. The effect of sex was significant only in two visual attention measures (Sky Search & Map) and interaction age and sex exerted a significant effect only in the dual task (Score DT). The results suggest that the Spanish version of the TEA-Ch (A) might be a useful instrument to evaluate attentional processes in Spanish child population.

  16. Low-Pressure Testing of the Mars Science Laboratory’s Solid Sampling System: Test Methods and Preliminary Results

    NASA Astrophysics Data System (ADS)

    Mukherjee, S.; von der Heydt, M.; Hanson, C.; Jandura, L.

    2009-12-01

    The Mars Science Laboratory mission is scheduled to launch in 2011 with an extensive suite of in situ science instruments. Acquiring, processing and delivering appropriate samples of rock and martian regolith to the instruments is a critical component in realizing the science capability of these payload elements. However, there are a number of challenges in validating the design of these systems. In particular, differences in the environment (atmospheric pressure and composition, temperature, gravity), target materials (variation in rock and soil properties), and state of the hardware (electrical potential, particulate coatings) may effect sampling performance. To better understand the end-to-end system and allow development of mitigation strategies if necessary, early testing of high-fidelity engineering models of the hardware in the solid sample chain is being conducted. The components of the sample acquisition, processing & delivery chain that will be tested are the drill, scoop, sieves, portioners, and instrument inlet funnels. An evaluation of the environmental parameter space was conducted to identify a subset that may have significant effects on sampling performance and cannot be well bounded by analysis. Accordingly, support equipment to enable testing at Mars surface pressures (5-10 Torr), with carbon dioxide was designed and built. A description of the testing set-up, investigations, and preliminary results will be presented.

  17. The Impact of Three Different Canal Lubricants on Fracture, Deformity and Metal Slivering of ProTaper Rotary Instruments

    PubMed Central

    Shantiaee, Yazdan; Dianat, Omid; Sharifi, Farnoud; Nahvi, Golnaz; Kolahi Ahari, Golbarg

    2014-01-01

    Introduction: The aim of this in vitro study was to evaluate the effect(s) of three canal lubricants i.e. sodium hypochlorite, RC-Prep as the paste form of ethylenediaminetetraacetic acid (EDTA) and aqueous EDTA on the occurrence/incidence of fracture, deformity and metal slivering of ProTaper rotary instruments. Methods: A total of 120 mesial canals (i.e. mesiobuccal and mesiolingual) of first mandibular molars or buccal canals (i.e. mesiobuccal and distobuccal) of first maxillary molars, with curvatures of 10-20 degrees were selected and randomly divided into three groups of forty samples each. These selected canals all had approximate 19-21 mm working length and apical diameter equal to a #15 K-file. In each group, the root canals were prepared using ProTaper rotary instruments with an electric motor using one of the three aforementioned irrigants. Subsequently, samples were compared to each other at different magnifications (16×, 20×, 40× and 57×) for any fracture, deformity or metal slivering, by the Cox regression analysis. Results: The fractures rate of samples in RC-Prep group was significantly higher compared to other groups (P=0.01). No evidence of instrument deformity was detected in any groups. A statistically significant reverse relation between metal slivering and instrument fracture was observed. Conclusions: Application of aqueous EDTA and/or sodium hypochlorite as intracanal lubricants caused less fracture of ProTaper instruments compared to canal lubrication with RC-Prep. PMID:24688582

  18. Evaluation of the safety and efficiency of novel metallic implant scaler tips manufactured by the powder injection molding technique.

    PubMed

    Chun, Kyung A; Kum, Kee-Yeon; Lee, Woo-Cheol; Baek, Seung-Ho; Choi, Hae-Won; Shon, Won-Jun

    2017-07-11

    Although many studies have compared the properties of ultrasonic scaling instruments, it remains controversial as to which is most suitable for implant scaling. This study evaluated the safety and efficiency of novel metallic ultrasonic scaler tips made by the powder injection molding (PIM) technique on titanium surfaces. Mechanical instrumentation was carried out using four types of metal scaler tips consisting of copper (CU), bronze (BR), 316 L stainless steel (316 L), and conventional stainless steel (SS) tips. The instrumented surface alteration image of samples was viewed with scanning electron microscope (SEM) and surface profile of the each sample was investigated with confocal laser scanning microscopy (CLSM). Arithmetic mean roughness (Ra) and maximum height roughness (Rmax) of titanium samples were measured and dissipated power of the scaler tip was estimated for scaling efficiency. The average Ra values caused by the 316 L and SS tip were about two times higher than those of the CU and BR tips (p < 0.05). The Rmax value showed similar results. The efficiency of the SS tip was about 3 times higher than that of CU tip, the 316 L tip is about 2.7 times higher than that of CU tip, and the BR tip is about 1.2 times higher than that of CU tip. Novel metallic bronze alloy ultrasonic scaler tip minimally damages titanium surfaces, similar to copper alloy tip. Therefore, this bronze alloy scaler tip may be promising instrument for implant maintenance therapy.

  19. Family context assessment in a public health study.

    PubMed

    Velasco, David; Sánchez de Miguel, Manuel; Egurza, Maitane; Arranz, Enrique; Aranbarri, Aritz; Fano, Eduardo; Ibarluzea, Jesús

    2014-01-01

    To analyze the factorial structure of a new instrument to assess the quality of the family context (Etxadi-Gangoiti Scale) in a sample from the Gipuzkoa cohort of the Environment and Childhood (Infancia y Medio Ambiente [INMA]) study. Families in a sample of 433 two-year-old children were assessed in a home visit with subsequent analysis of the factorial structure and psychometric properties of the data. An exploratory factorial analysis (principal axis factoring and varimax rotation) and a confirmatory factorial analysis were carried out; partial confirmation of the original factorial structure of the instrument was obtained, which revealed the following factorial structures. Subscale (1): promotion of cognitive and linguistic development, social skills, psychomotor skills, and pretend play and imitation; subscale (2): promotion of independence and self-esteem, provision of optimal frustration, social and emotional quality of the relationship, and absence of physical punishment; subscale (3): paternal involvement, low exposure to family conflict, low frequency of family conflict, relationship with the extended family, social support, diversity of experiences, low frequency of stressful events, and low parental perception of stress. The structure of the original instrument structure was partially confirmed, which was attributed to the characteristics of the sample. We stress the importance of the variability obtained in the evaluation of the families, as well as of adequate indicators of reliability in such evaluation. The new instrument could be used in public health to identify deficient family contexts and to design preventive interventions focused on parenting skills. Copyright © 2013 SESPAS. Published by Elsevier Espana. All rights reserved.

  20. Evaluation of History Interest Inventory--Development and Evaluation of a History Interest Inventory for Chinese K-12 Students

    ERIC Educational Resources Information Center

    Dan, Yongjun; Wei, Tianlan; Zhao, Wenjun

    2013-01-01

    The purpose of this study was to develop and evaluate a History Interest Inventory (HII) to measure Chinese K-12 students' history interest. In this study, data were drawn from two independent samples of a city in Eastern China, and exploratory factor analysis (EFA) and confirmatory factor analysis (CFA) were conducted to reduce instrument size…

  1. Evaluating the Inter-Respondent (Consumer vs. Staff) Reliability and Construct Validity (SIS vs. Vineland) of the Supports Intensity Scale on a Dutch Sample

    ERIC Educational Resources Information Center

    Claes, C.; Van Hove, G.; van Loon, J.; Vandevelde, S.; Schalock, R. L.

    2009-01-01

    Background: Despite various reliability studies on the Supports Intensity Scale (SIS), to date there has not been an evaluation of the reliability of client vs. staff judgments. Such determination is important, given the increasing consumer-driven approach to services. Additionally, there has not been an evaluation of the instrument's construct…

  2. Validity and reliability of the Turkish version of the pressure ulcer prevention knowledge assessment instrument.

    PubMed

    Tulek, Zeliha; Polat, Cansu; Ozkan, Ilknur; Theofanidis, Dimitris; Togrol, Rifat Erdem

    2016-11-01

    Sound knowledge of pressure ulcers is important to enable good prevention. There are limited instruments assessing pressure ulcer knowledge. The Pressure Ulcer Prevention Knowledge Assessment Instrument is among the scales of which psychometric properties have been studied rigorously and reflects the latest evidence. This study aimed to evaluate the validity and reliability of the Turkish version of the Pressure Ulcer Prevention Knowledge Assessment Instrument (PUPKAI-T), an instrument that assesses knowledge of pressure ulcer prevention by using multiple-choice questions. Linguistic validity was verified through front-to-back translation. Psychometric properties of the instrument were studied on a sample of 150 nurses working in a tertiary hospital in Istanbul, Turkey. The content validity index of the translated instrument was 0.94, intra-class correlation coefficients were between 0.37 and 0.80, item difficulty indices were between 0.21 and 0.88, discrimination indices were 0.20-0.78, and the Kuder Richardson for the internal consistency was 0.803. The PUPKAI-T was found to be a valid and reliable tool to evaluate nurses' knowledge on pressure ulcer prevention. The PUPKAI-T may be a useful tool for determining educational needs of nurses on pressure ulcer prevention. Copyright © 2016 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  3. Mapping between 6 Multiattribute Utility Instruments.

    PubMed

    Chen, Gang; Khan, Munir A; Iezzi, Angelo; Ratcliffe, Julie; Richardson, Jeff

    2016-02-01

    Cost-utility analyses commonly employ a multiattribute utility (MAU) instrument to estimate the health state utilities, which are needed to calculate quality-adjusted life years. Different MAU instruments predict significantly different utilities, which makes comparison of results from different evaluation studies problematical. This article presents mapping functions ("crosswalks") from 6 MAU instruments (EQ-5D-5L, SF-6D, Health Utilities Index 3 [HUI 3], 15D, Quality of Well-Being [QWB], and Assessment of Quality of Life 8D [AQoL-8D]) to each of the other 5 instruments in the study: a total of 30 mapping functions. Data were obtained from a multi-instrument comparison survey of the public and patients in 7 disease areas conducted in 6 countries (Australia, Canada, Germany, Norway, United Kingdom, and United States). The 8022 respondents were administered each of the 6 study instruments. Mapping equations between each instrument pair were estimated using 4 econometric techniques: ordinary least squares, generalized linear model, censored least absolute deviations, and, for the first time, a robust MM-estimator. Goodness-of-fit indicators for each of the results are within the range of published studies. Transformations reduced discrepancies between predicted utilities. Incremental utilities, which determine the value of quality-related health benefits, are almost perfectly aligned at the sample means. Transformations presented here align the measurement scales of MAU instruments. Their use will increase confidence in the comparability of evaluation studies, which have employed different MAU instruments. © The Author(s) 2015.

  4. A Framework for Establishing Standard Reference Scale of Texture by Multivariate Statistical Analysis Based on Instrumental Measurement and Sensory Evaluation.

    PubMed

    Zhi, Ruicong; Zhao, Lei; Xie, Nan; Wang, Houyin; Shi, Bolin; Shi, Jingye

    2016-01-13

    A framework of establishing standard reference scale (texture) is proposed by multivariate statistical analysis according to instrumental measurement and sensory evaluation. Multivariate statistical analysis is conducted to rapidly select typical reference samples with characteristics of universality, representativeness, stability, substitutability, and traceability. The reasonableness of the framework method is verified by establishing standard reference scale of texture attribute (hardness) with Chinese well-known food. More than 100 food products in 16 categories were tested using instrumental measurement (TPA test), and the result was analyzed with clustering analysis, principal component analysis, relative standard deviation, and analysis of variance. As a result, nine kinds of foods were determined to construct the hardness standard reference scale. The results indicate that the regression coefficient between the estimated sensory value and the instrumentally measured value is significant (R(2) = 0.9765), which fits well with Stevens's theory. The research provides reliable a theoretical basis and practical guide for quantitative standard reference scale establishment on food texture characteristics.

  5. Histological evaluation of the cleaning effectiveness of two reciprocating single-file systems in severely curved root canals: Reciproc versus WaveOne.

    PubMed

    Carvalho, Maira de Souza; Junior, Emílio Carlos Sponchiado; Bitencourt Garrido, Angela Delfina; Roberti Garcia, Lucas da Fonseca; Franco Marques, André Augusto

    2015-01-01

    The aim of this study was to evaluate the cleaning effectiveness achieved with two reciprocating single-file systems in severely curved root canals: Reciproc and WaveOne. Twenty-five mesial roots of mandibular molars were randomly separated into two groups, according to the instrumentation system used. The negative control group consisted of five specimens that were not instrumented. The mesial canals (buccal and lingual) in Reciproc Group were instrumented with file R25 and the WaveOne group with the Primary file. The samples were submitted to histological processing and analyzed under a digital microscope. The WaveOne group presented a larger amount of debris than the Reciproc Group, however, without statistically significant difference (P > 0.05). A larger amount of debris in the control group was observed, with statistically significant difference to Reciproc and WaveOne groups (P < 0.05). The two reciprocating single-file instrumentation systems presented similar effectiveness for root canal cleaning.

  6. Rapid assessment of agents of biological terrorism: defining the differential diagnosis of inhalational anthrax using electronic communication in a practice-based research network.

    PubMed

    Temte, Jonathan L; Anderson, Anna Lisa

    2004-01-01

    Early detection of bioterrorism requires assessment of diagnoses assigned to cases of rare diseases with which clinicians have little experience. In this study, we evaluated the process of defining the differential diagnosis for inhalational anthrax using electronic communication within a practice-based research network (PBRN) and compared the results with those obtained from a nationwide random sample of family physicians with a mailed instrument. We distributed survey instruments by e-mail to 55 physician members of the Wisconsin Research Network (WReN), a regional PBRN. The instruments consisted of 3 case vignettes randomly drawn from a set describing 11 patients with inhalational anthrax, 2 with influenza A, and 1 with Legionella pneumonia. Physicians provided their most likely nonanthrax diagnosis, along with their responses to 4 yes-or-no management questions for each case. Physicians who had not responded at 1 week received a second e-mail with the survey instrument. The comparison group consisted of the nationwide sample of physicians who completed mailed survey instruments. Primary outcome measures were response rate, median response time, and frequencies of diagnostic categories assigned to cases of inhalational anthrax. The PBRN response rate compared favorably with that of the national sample (47.3% vs 37.0%; P = not significant). The median response time for the PBRN was significantly shorter than that for the national sample (2 vs 28 days; P < .001). No significant differences were found between the PBRN and the Midwest subset of the national sample in the frequencies of major diagnostic categories or in case management. Electronic means of creating differential diagnoses for rare infectious diseases of national significance is feasible within PBRNs. Information is much more rapidly acquired and is consistent with that obtained by conventional methods.

  7. Psychometric evaluation of the Shared Decision-Making Instrument--Revised.

    PubMed

    Bartlett, Jacqueline A; Peterson, Jane A

    2013-02-01

    The purpose of this study was to evaluate the psychometric properties of the Shared Decision-Making Inventory-Revised (SDMI-R) to measure four constructs (knowledge, attitudes, self-efficacy, and intent) theoretically defined as vital in discussing the human papillomavirus (HPV) disease and vaccine with clients. The SDMI-R was distributed to a sample (N = 1,525) of school nurses. Correlational matrixes denoted moderate to strong correlations, indicating adequate internal reliability. Reliability for the total instrument was satisfactory (α = .874) along with Attitude, Self-Efficacy and Intent subscales .828, .917, .891, respectively. Exploratory factor analysis revealed five components that explained 75.96% of the variance.

  8. A Process Evaluation of Project Developmental Continuity, Interim Report VI: Recommendations for Continuing the Impact Study.

    ERIC Educational Resources Information Center

    Granville, Arthur; And Others

    This interim report re-examines data on instrument suitability, comparability of groups, and adequacy of sample size in Year III of the process evaluation of Project Developmental Continuity (PDC) and offers preliminary recommendations concerning the feasibility of continuing the impact study. PDC is a Head Start demonstration program aimed at…

  9. Factor Structure of the DSM-IV Criteria for College Students Using the Adult Behavior Checklist.

    ERIC Educational Resources Information Center

    Johnson, Brian D.; Smith, Everett V., Jr.

    1998-01-01

    The factor structure of the "Diagnostic and Statistical Manual of Mental Disorders" (DSM-IV) criteria for attention deficit hyperactivity disorder (ADHD) is evaluated in a sample of 1,503 college students. The Adult Behavior Checklist is evaluated as a screening instrument. Results support the extension of ADHD criteria for diagnosis to college…

  10. Scale Refinement and Initial Evaluation of a Behavioral Health Function Measurement Tool for Work Disability Evaluation

    PubMed Central

    Marfeo, Elizabeth E.; Ni, Pengsheng; Bogusz, Kara; Meterko, Mark; McDonough, Christine M.; Chan, Leighton; Rasch, Elizabeth K.; Brandt, Diane E.; Jette, Alan M.

    2014-01-01

    Objectives To use item response theory (IRT) data simulations to construct and perform initial psychometric testing of a newly developed instrument, the Social Security Administration Behavioral Health Function (SSA-BH) instrument, that aims to assess behavioral health functioning relevant to the context of work. Design Cross-sectional survey followed by item response theory (IRT) calibration data simulations Setting Community Participants A sample of individuals applying for SSA disability benefits, claimants (N=1015), and a normative comparative sample of US adults (N=1000) Interventions None. Main Outcome Measure Social Security Administration Behavioral Health Function (SSA-BH) measurement instrument Results Item response theory analyses supported the unidimensionality of four SSA-BH scales: Mood and Emotions (35 items), Self-Efficacy (23 items), Social Interactions (6 items), and Behavioral Control (15 items). All SSA-BH scales demonstrated strong psychometric properties including reliability, accuracy, and breadth of coverage. High correlations of the simulated 5- or 10- item CATs with the full item bank indicated robust ability of the CAT approach to comprehensively characterize behavioral health function along four distinct dimensions. Conclusions Initial testing and evaluation of the SSA-BH instrument demonstrated good accuracy, reliability, and content coverage along all four scales. Behavioral function profiles of SSA claimants were generated and compared to age and sex matched norms along four scales: Mood and Emotions, Behavioral Control, Social Interactions, and Self-Efficacy. Utilizing the CAT based approach offers the ability to collect standardized, comprehensive functional information about claimants in an efficient way, which may prove useful in the context of the SSA’s work disability programs. PMID:23542404

  11. [Construct validity of a Portuguese version of the Female Sexual Function Index].

    PubMed

    Pacagnella, Rodolfo de Carvalho; Martinez, Edson Zangiacomi; Vieira, Elisabeth Meloni

    2009-11-01

    This study aimed to evaluate the construct validity of a version of the Female Sexual Function Index (FSFI). The version was inserted into a multidimensional questionnaire and applied face-to-face to 235 sterilized women. Non-response rate was 1.7%. The sample proved to be highly homogeneous, with low income and education. Cronbach's alpha of 0.948 indicated high internal consistency. Factor analysis showed that the instrument was measuring four factors: desire/arousal, lubrication, orgasm/satisfaction, and pain. This may reflect characteristics of the instrument itself, female sexual response, or even the sample's cultural peculiarities, which can affect understanding of the questions or concepts with which the instrument deals. This study emphasizes the need for further research in the general population to determine the psychometric properties of the FSFI, such as its factor composition and definition of appropriate cut-off points for the Brazilian population.

  12. Instrumental resolution as a function of scattering angle and wavelength as exemplified for the POWGEN instrument

    PubMed Central

    Jacobs, Philipp; Houben, Andreas; Schweika, Werner; Tchougréeff, Andrei L.; Dronskowski, Richard

    2017-01-01

    The method of angular- and wavelength-dispersive (e.g. two-dimensional) Rietveld refinement is a new and emerging tool for the analysis of neutron diffraction data measured at time-of-flight instruments with large area detectors. Following the approach for one-dimensional refinements (using either scattering angle or time of flight), the first step at each beam time cycle is the calibration of the instrument including the determination of instrumental contributions to the peak shape variation to be expected for diffraction patterns measured by the users. The aim of this work is to provide the users with calibration files and – for the later Rietveld refinement of the measured data – with an instrumental resolution file (IRF). This article will elaborate on the necessary steps to generate such an IRF for the angular- and wavelength-dispersive case, exemplified for the POWGEN instrument. A dataset measured on a standard diamond sample is used to extract the profile function in the two-dimensional case. It is found that the variation of reflection width with 2θ and λ can be expressed by the standard equation used for evaluating the instrumental resolution, which yields a substantially more fundamental approach to the parameterization of the instrumental contribution to the peak shape. Geometrical considerations of the POWGEN instrument and sample effects lead to values for Δθ, Δt and ΔL that yield a very good match to the extracted FWHM values. In a final step the refinement results are compared with the one-dimensional, i.e. diffraction-focused, case. PMID:28656041

  13. Evaluation of the Clinical LOINC (Logical Observation Identifiers, Names, and Codes) Semantic Structure as a Terminology Model for Standardized Assessment Measures

    PubMed Central

    Bakken, Suzanne; Cimino, James J.; Haskell, Robert; Kukafka, Rita; Matsumoto, Cindi; Chan, Garrett K.; Huff, Stanley M.

    2000-01-01

    Objective: The purpose of this study was to test the adequacy of the Clinical LOINC (Logical Observation Identifiers, Names, and Codes) semantic structure as a terminology model for standardized assessment measures. Methods: After extension of the definitions, 1,096 items from 35 standardized assessment instruments were dissected into the elements of the Clinical LOINC semantic structure. An additional coder dissected at least one randomly selected item from each instrument. When multiple scale types occurred in a single instrument, a second coder dissected one randomly selected item representative of each scale type. Results: The results support the adequacy of the Clinical LOINC semantic structure as a terminology model for standardized assessments. Using the revised definitions, the coders were able to dissect into the elements of Clinical LOINC all the standardized assessment items in the sample instruments. Percentage agreement for each element was as follows: component, 100 percent; property, 87.8 percent; timing, 82.9 percent; system/sample, 100 percent; scale, 92.6 percent; and method, 97.6 percent. Discussion: This evaluation was an initial step toward the representation of standardized assessment items in a manner that facilitates data sharing and re-use. Further clarification of the definitions, especially those related to time and property, is required to improve inter-rater reliability and to harmonize the representations with similar items already in LOINC. PMID:11062226

  14. Psychometric Properties of a Screening Instrument for Domestic Violence in a Sample of Iranian Women

    PubMed Central

    Azadarmaki, Taghi; Kassani, Aziz; Menati, Rostam; Hassanzadeh, Jafar; Menati, Walieh

    2016-01-01

    Background Domestic violence against women is regarded as an important health problem among women and a serious concern in issues related to human rights. To date, a few screening tools for domestic violence exist for Iranian married women, but they assess only some of the domestic violence components. Objectives The present study aimed to design and determine the validity and reliability of a screening instrument for domestic violence in a sample of Iranian women. Materials and Methods The present study was a cross-sectional psychometric evaluation conducted on 350 married women in Ilam, Iran, in 2014. The samples were selected through multistage sampling and the main method was cluster sampling. A 20-item, self-administered questionnaire was validated by exploratory factor analysis (EFA) and confirmatory factor analysis (CFA). An Eigen value > 1 and a loading factor > 0.3 for each component were considered as indices for extracting domestic violence components. Reliability was calculated by test-retest and Cronbach’s alpha. Also, the content validity index (CVI) and content validity ratio (CVR) were used to measure content validity. The data were analyzed using SPSS-13 and LISREL 8.8 software programs. Results The self-administered instrument was completed by 334 women. The CFA and EFA methods confirmed embedding items and the three-factor structure of the instrument including psychological, physical, and sexual violence, which explained 66% of the total variance of the domestic violence. The ICC and Cronbach’s alpha coefficients were > 0.7 for the components of the questionnaire. The test-retest also revealed strong correlations for each of the domestic violence components (r > 0.6). Conclusions The used instrument for measuring domestic violence had desirable validity and reliability and can be used as a suitable instrument in health and social researches in the local population. PMID:27331052

  15. Development of a survey instrument to measure connectivity to evaluate national public health preparedness and response performance.

    PubMed

    Dorn, Barry C; Savoia, Elena; Testa, Marcia A; Stoto, Michael A; Marcus, Leonard J

    2007-01-01

    Survey instruments for evaluating public health preparedness have focused on measuring the structure and capacity of local, state, and federal agencies, rather than linkages among structure, process, and outcomes. To focus evaluation on the latter, we evaluated the linkages among individuals, organizations, and systems using the construct of "connectivity" and developed a measurement instrument. Results from focus groups of emergency preparedness first responders generated 62 items used in the development sample of 187 respondents. Item reduction and factors analyses were conducted to confirm the scale's components. The 62 items were reduced to 28. Five scales explained 70% of the total variance (number of items, percent variance explained, Cronbach's alpha) including connectivity with the system (8, 45%, 0.94), coworkers (7, 7%, 0.91), organization (7, 12%, 0.93), and perceptions (6, 6%, 0.90). Discriminant validity was found to be consistent with the factor structure. We developed a Connectivity Measurement Tool for the public health workforce consisting of a 34-item questionnaire found to be a reliable measure of connectivity with preliminary evidence of construct validity.

  16. Evaluation of a multi-fibre needle Raman probe for tissue analysis

    NASA Astrophysics Data System (ADS)

    Fullwood, Leanne M.; Iping Petterson, Ingeborg E.; Dudgeon, Alexander P.; Lloyd, Gavin R.; Kendall, Catherine; Hall, Charlie; Day, John C. C.; Stone, Nick

    2016-03-01

    Raman spectroscopy is a rapid technique for the identification of cancers. Its coupling with a hypodermic needle provides a minimally invasive instrument with the potential to aid real time assessment of suspicious lesions in vivo and guide surgery. A fibre optic Raman needle probe was utilised in this study to evaluate the classification ability of the instrument as a diagnostic tool together with multivariate analysis, through measurements of tissues from different animal species as well as various different porcine tissue types. Cross validation was performed and preliminary classification accuracies were calculated as 100% for the identification of tissue type and 97.5% for the identification of animal species. A lymph node sample was also measured using the needle probe to assess the use of the technique for human tissue and hence its efficiency as a clinical instrument. This needle probe has been demonstrated to have the capabilities to classify tissue samples based on their biochemical components. The Raman needle probe also has the potential to act as a diagnostic and surgical tool to delineate cancerous from non-cancerous cells in real time, thus assisting complete removal of a tumour.

  17. Development and evaluation of the Korean Health Literacy Instrument.

    PubMed

    Kang, Soo Jin; Lee, Tae Wha; Paasche-Orlow, Michael K; Kim, Gwang Suk; Won, Hee Kwan

    2014-01-01

    The purpose of this study is to develop and validate the Korean Health Literacy Instrument, which measures the capacity to understand and use health-related information and make informed health decisions in Korean adults. In Phase 1, 33 initial items were generated to measure functional, interactive, and critical health literacy with prose, document, and numeracy tasks. These items included content from health promotion, disease management, and health navigation contexts. Content validity assessment was conducted by an expert panel, and 11 items were excluded. In Phase 2, the 22 remaining items were administered to a convenience sample of 292 adults from community and clinical settings. Exploratory factor and item difficulty and discrimination analyses were conducted and four items with low discrimination were deleted. In Phase 3, the remaining 18 items were administered to a convenience sample of 315 adults 40-64 years of age from community and clinical settings. A confirmatory factor analysis was performed to test the construct validity of the instrument. The Korean Health Literacy Instrument has a range of 0 to 18. The mean score in our validation study was 11.98. The instrument exhibited an internal consistency reliability coefficient of 0.82, and a test-retest reliability of 0.89. The instrument is suitable for screening individuals who have limited health literacy skills. Future studies are needed to further define the psychometric properties and predictive validity of the Korean Health Literacy Instrument.

  18. Assessing medical professionalism: A systematic review of instruments and their measurement properties.

    PubMed

    Li, Honghe; Ding, Ning; Zhang, Yuanyuan; Liu, Yang; Wen, Deliang

    2017-01-01

    Over the last three decades, various instruments were developed and employed to assess medical professionalism, but their measurement properties have yet to be fully evaluated. This study aimed to systematically evaluate these instruments' measurement properties and the methodological quality of their related studies within a universally acceptable standardized framework and then provide corresponding recommendations. A systematic search of the electronic databases PubMed, Web of Science, and PsycINFO was conducted to collect studies published from 1990-2015. After screening titles, abstracts, and full texts for eligibility, the articles included in this study were classified according to their respective instrument's usage. A two-phase assessment was conducted: 1) methodological quality was assessed by following the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) checklist; and 2) the quality of measurement properties was assessed according to Terwee's criteria. Results were integrated using best-evidence synthesis to look for recommendable instruments. After screening 2,959 records, 74 instruments from 80 existing studies were included. The overall methodological quality of these studies was unsatisfactory, with reasons including but not limited to unknown missing data, inadequate sample sizes, and vague hypotheses. Content validity, cross-cultural validity, and criterion validity were either unreported or negative ratings in most studies. Based on best-evidence synthesis, three instruments were recommended: Hisar's instrument for nursing students, Nurse Practitioners' Roles and Competencies Scale, and Perceived Faculty Competency Inventory. Although instruments measuring medical professionalism are diverse, only a limited number of studies were methodologically sound. Future studies should give priority to systematically improving the performance of existing instruments and to longitudinal studies.

  19. Comparative evaluation of the accuracy of linear measurements between cone beam computed tomography and 3D microtomography.

    PubMed

    Mangione, Francesca; Meleo, Deborah; Talocco, Marco; Pecci, Raffaella; Pacifici, Luciano; Bedini, Rossella

    2013-01-01

    The aim of this study was to evaluate the influence of artifacts on the accuracy of linear measurements estimated with a common cone beam computed tomography (CBCT) system used in dental clinical practice, by comparing it with microCT system as standard reference. Ten bovine bone cylindrical samples containing one implant each, able to provide both points of reference and image quality degradation, have been scanned by CBCT and microCT systems. Thanks to the software of the two systems, for each cylindrical sample, two diameters taken at different levels, by using implants different points as references, have been measured. Results have been analyzed by ANOVA and a significant statistically difference has been found. Due to the obtained results, in this work it is possible to say that the measurements made with the two different instruments are still not statistically comparable, although in some samples were obtained similar performances and therefore not statistically significant. With the improvement of the hardware and software of CBCT systems, in the near future the two instruments will be able to provide similar performances.

  20. Design and Elementary Evaluation of a Highly-Automated Fluorescence-Based Instrument System for On-Site Detection of Food-Borne Pathogens

    PubMed Central

    Lu, Zhan; Zhang, Jianyi; Xu, Lizhou; Li, Yanbin; Chen, Siyu; Ye, Zunzhong; Wang, Jianping

    2017-01-01

    A simple, highly-automated instrument system used for on-site detection of foodborne pathogens based on fluorescence was designed, fabricated, and preliminarily tested in this paper. A corresponding method has been proved effective in our previous studies. This system utilizes a light-emitting diode (LED) to excite fluorescent labels and a spectrometer to record the fluorescence signal from samples. A rotation stage for positioning and switching samples was innovatively designed for high-throughput detection, ten at most in one single run. We also developed software based on LabVIEW for data receiving, processing, and the control of the whole system. In the test of using a pure quantum dot (QD) solution as a standard sample, detection results from this home-made system were highly-relevant with that from a well-commercialized product and even slightly better reproducibility was found. And in the test of three typical kinds of food-borne pathogens, fluorescence signals recorded by this system are highly proportional to the variation of the sample concentration, with a satisfied limit of detection (LOD) (nearly 102–103 CFU·mL−1 in food samples). Additionally, this instrument system is low-cost and easy-to-use, showing a promising potential for on-site rapid detection of food-borne pathogens. PMID:28241478

  1. Design and Elementary Evaluation of a Highly-Automated Fluorescence-Based Instrument System for On-Site Detection of Food-Borne Pathogens.

    PubMed

    Lu, Zhan; Zhang, Jianyi; Xu, Lizhou; Li, Yanbin; Chen, Siyu; Ye, Zunzhong; Wang, Jianping

    2017-02-23

    A simple, highly-automated instrument system used for on-site detection of foodborne pathogens based on fluorescence was designed, fabricated, and preliminarily tested in this paper. A corresponding method has been proved effective in our previous studies. This system utilizes a light-emitting diode (LED) to excite fluorescent labels and a spectrometer to record the fluorescence signal from samples. A rotation stage for positioning and switching samples was innovatively designed for high-throughput detection, ten at most in one single run. We also developed software based on LabVIEW for data receiving, processing, and the control of the whole system. In the test of using a pure quantum dot (QD) solution as a standard sample, detection results from this home-made system were highly-relevant with that from a well-commercialized product and even slightly better reproducibility was found. And in the test of three typical kinds of food-borne pathogens, fluorescence signals recorded by this system are highly proportional to the variation of the sample concentration, with a satisfied limit of detection (LOD) (nearly 10²-10³ CFU·mL -1 in food samples). Additionally, this instrument system is low-cost and easy-to-use, showing a promising potential for on-site rapid detection of food-borne pathogens.

  2. Routine low-level monitoring of polar pesticides and pesticide degradates by HPLC/ESI-MS: Evaluating long-term performance

    USGS Publications Warehouse

    Furlong, E.T.; Martin, Jeffrey D.; Werner, S.L.; Gates, Paul M.

    2002-01-01

    The sensitivity and selective determination of polar pesticides were analyzed using high-performance liquid chromatography/electrospray ionization-mass spectrometry (HPLC/ESI-MS). The effects of multiple operators and instruments on method performance were evaluated using 440 pairs of fortified reagent-water and blank reagent-water samples. The influence of varying environmental matrices on recovery and precision were also analyzed using 200 fortified ambient water samples and duplicate ambient water samples. The results show that compound stability in filtered water was matrix-, chemical class- and compound-dependent which ranged from 1 day to 2 weeks.

  3. Evaluation of Immunoassays and General Biological Indicator Tests for Field Screening of Bacillus anthracis and Ricin

    PubMed Central

    Bartholomew, Rachel A.; Ozanich, Richard M.; Arce, Jennifer S.; Engelmann, Heather E.; Heredia-Langner, Alejandro; Hofstad, Beth A.; Hutchison, Janine R.; Jarman, Kristin; Melville, Angela M.; Victry, Kristin D.

    2017-01-01

    There is little published data on the performance of biological indicator tests and immunoassays that could be used by first responders to determine if a suspicious powder contains a potential biothreat agent. We evaluated a range of biological indicator tests, including 3 protein tests, 2 ATP tests, 1 DNA test, and 1 FTIR spectroscopy instrument for their ability to screen suspicious powders for Bacillus anthracis (B. anthracis) spores and ricin. We also evaluated 12 immunoassays (mostly lateral flow immunoassays) for their ability to screen for B. anthracis and ricin. We used a cost-effective, statistically based test plan that allows instruments to be evaluated at performance levels ranging from 0.85 to 0.95 lower confidence bound of the probability of detection at confidence levels of 80% to 95%. We also assessed interference with 22 common suspicious powders encountered in the field. The detection reproducibility for the biological indicators was evaluated at 108 B. anthracis spores and 62.5 μg ricin, and the immunoassay detection reproducibility was evaluated at 107 spores/mL (B. anthracis) and 0.1 μg/mL (ricin). Seven out of 12 immunoassays met our most stringent criteria for B. anthracis detection, while 9 out of 12 met our most stringent test criteria for ricin detection. Most of the immunoassays also detected ricin in 3 different crude castor seed preparations. Our testing results varied across products and sample preparations, indicating the importance of reviewing performance data for specific instruments and sample types of interest for the application in order to make informed decisions regarding the selection of biodetection equipment for field use. PMID:28192054

  4. Evaluation of Immunoassays and General Biological Indicator Tests for Field Screening of Bacillus anthracis and Ricin.

    PubMed

    Bartholomew, Rachel A; Ozanich, Richard M; Arce, Jennifer S; Engelmann, Heather E; Heredia-Langner, Alejandro; Hofstad, Beth A; Hutchison, Janine R; Jarman, Kristin; Melville, Angela M; Victry, Kristin D; Bruckner-Lea, Cynthia J

    There is little published data on the performance of biological indicator tests and immunoassays that could be used by first responders to determine if a suspicious powder contains a potential biothreat agent. We evaluated a range of biological indicator tests, including 3 protein tests, 2 ATP tests, 1 DNA test, and 1 FTIR spectroscopy instrument for their ability to screen suspicious powders for Bacillus anthracis (B. anthracis) spores and ricin. We also evaluated 12 immunoassays (mostly lateral flow immunoassays) for their ability to screen for B. anthracis and ricin. We used a cost-effective, statistically based test plan that allows instruments to be evaluated at performance levels ranging from 0.85 to 0.95 lower confidence bound of the probability of detection at confidence levels of 80% to 95%. We also assessed interference with 22 common suspicious powders encountered in the field. The detection reproducibility for the biological indicators was evaluated at 10 8 B. anthracis spores and 62.5 μg ricin, and the immunoassay detection reproducibility was evaluated at 10 7 spores/mL (B. anthracis) and 0.1 μg/mL (ricin). Seven out of 12 immunoassays met our most stringent criteria for B. anthracis detection, while 9 out of 12 met our most stringent test criteria for ricin detection. Most of the immunoassays also detected ricin in 3 different crude castor seed preparations. Our testing results varied across products and sample preparations, indicating the importance of reviewing performance data for specific instruments and sample types of interest for the application in order to make informed decisions regarding the selection of biodetection equipment for field use.

  5. Multi-Center Evaluation of the Automated Immunohematology Instrument, the ORTHO VISION Analyzer.

    PubMed

    Aysola, Agnes; Wheeler, Leslie; Brown, Richard; Denham, Rebecca; Colavecchia, Connie; Pavenski, Katerina; Krok, Elizabeth; Hayes, Chelsea; Klapper, Ellen

    2017-02-01

    ORTHO VISION Analyzer (Vision), is an immunohematology instrument using ID-MT gel card technology with digital image processing. It has a continuous, random sample access with STAT priority processing. The efficiency and ease of operation of Vision was evaluated at 5 medical centers. De-identified patient samples were tested on the ORTHO ProVue Analyzer (ProVue) and repeated on the Vision mimicking the daily workload pattern. Turnaround times (TAT) were collected and compared. Operators rated key features of the analyzer on a scale of 1 to 5. A total of 507 samples were tested on both instruments at the 5 trial sites. The mean TAT (SD) were 31.6 minutes (5.5) with Vision and 35.7 minutes (8.4) with ProVue, which renders a 12% reduction. Type and screens were performed on 381 samples; the mean TAT (SD) was 32.2 minutes (4.5) with Vision and 37.0 minutes (7.4) with ProVue. Antibody identification with eleven panel cells was performed on 134 samples on Vision; TAT (SD) was 43.2 minutes (8.3). The installation, training, configuration, maintenance and validation processes are all streamlined to provide a short implementation time. The average rating of main functions by the operators was 4.1 to 4.8. Opportunities for improvement, such as flexibility with editing QC results, maintenance schedule, and printing options were identified. The capabilities to perform serial dilutions, to accept pediatric tubes, and review results by e-Connectivity are enhancements over the ProVue. Vision provides shorter TAT compared to ProVue. Every site described a positive experience using Vision. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Agents of support: psychometric properties of the Cancer Perceived Agents of Social Support (CPASS) questionnaire.

    PubMed

    Goldzweig, Gil; Hasson-Ohayon, Ilanit; Meirovitz, Amichay; Braun, Michal; Hubert, Ayala; Baider, Lea

    2010-11-01

    The current study presents the development and the evaluation of the psychometric properties of the Cancer Perceived Agents of Social Support (CPASS). The CPASS is a new self-rating instrument devised in order to enable both cancer patients and their spouses to report on the level of perceived social support they get. The CPASS evaluates the support given by different agents of support (spouse, family, friends and spiritual or religious beliefs) in several dimensions (emotional, cognitive and instrumental). The study sample comprised 662 cancer patients and their spouses recruited during a routine medical evaluation from three major cancer centers in Israel. The participants completed the CPASS and two other standardized instruments: The ENRICH Marital Satisfaction Scale (EMS) and the Brief Symptom Inventory (BSI). Principal component analysis confirmed a three-factor structure based upon the agent of support (spouse; friends/family; spiritual/religious beliefs). Cronbach's α coefficients for the agent of support indexes were high (0.80-0.95), while Cronbach's α levels for the kind of support were lower (0.45-0.72). Smallest Space Analysis (SSA) also confirmed the theoretical structure of the CPASS. Pearson correlation coefficients to the other study variables were high and significant. As a whole, the CPASS was found to be a valid tool for the current Israeli sample. Theoretical and practical conclusions and socio-cultural implications are discussed. Copyright © 2009 John Wiley & Sons, Ltd.

  7. Clinimetric evaluation of shoulder disability questionnaires: a systematic review of the literature

    PubMed Central

    Bot, S; Terwee, C; van der Windt, D A W M; Bouter, L; Dekker, J; de Vet, H C W

    2004-01-01

    Methods: Systematic literature searches were performed to identify self administered shoulder disability questionnaires. A checklist was developed to evaluate and compare the clinimetric quality of the instruments. Results: Two reviewers identified and evaluated 16 questionnaires by our checklist. Most studies were found for the Disability of the Arm, Shoulder, and Hand scale (DASH), the Shoulder Pain and Disability Index (SPADI), and the American Shoulder and Elbow Surgeons Standardised Shoulder Assessment Form (ASES). None of the questionnaires demonstrated satisfactory results for all properties. Most questionnaires claim to measure several domains (for example, pain, physical, emotional, and social functioning), yet dimensionality was studied in only three instruments. The internal consistency was calculated for seven questionnaires and only one received an adequate rating. Twelve questionnaires received positive ratings for construct validity, although depending on the population studied, four of these questionnaires received poor ratings too. Seven questionnaires were shown to have adequate test-retest reliability (ICC >0.70), but five questionnaires were tested inadequately. In most clinimetric studies only small sample sizes (n<43) were used. Nearly all publications lacked information on the interpretation of scores. Conclusion: The DASH, SPADI, and ASES have been studied most extensively, and yet even published validation studies of these instruments have limitations in study design, sample sizes, or evidence for dimensionality. Overall, the DASH received the best ratings for its clinimetric properties. PMID:15020324

  8. GeoLab: A Geological Workstation for Future Missions

    NASA Technical Reports Server (NTRS)

    Evans, Cynthia; Calaway, Michael; Bell, Mary Sue; Li, Zheng; Tong, Shuo; Zhong, Ye; Dahiwala, Ravi

    2014-01-01

    The GeoLab glovebox was, until November 2012, fully integrated into NASA's Deep Space Habitat (DSH) Analog Testbed. The conceptual design for GeoLab came from several sources, including current research instruments (Microgravity Science Glovebox) used on the International Space Station, existing Astromaterials Curation Laboratory hardware and clean room procedures, and mission scenarios developed for earlier programs. GeoLab allowed NASA scientists to test science operations related to contained sample examination during simulated exploration missions. The team demonstrated science operations that enhance theThe GeoLab glovebox was, until November 2012, fully integrated into NASA's Deep Space Habitat (DSH) Analog Testbed. The conceptual design for GeoLab came from several sources, including current research instruments (Microgravity Science Glovebox) used on the International Space Station, existing Astromaterials Curation Laboratory hardware and clean room procedures, and mission scenarios developed for earlier programs. GeoLab allowed NASA scientists to test science operations related to contained sample examination during simulated exploration missions. The team demonstrated science operations that enhance the early scientific returns from future missions and ensure that the best samples are selected for Earth return. The facility was also designed to foster the development of instrument technology. Since 2009, when GeoLab design and construction began, the GeoLab team [a group of scientists from the Astromaterials Acquisition and Curation Office within the Astromaterials Research and Exploration Science (ARES) Directorate at JSC] has progressively developed and reconfigured the GeoLab hardware and software interfaces and developed test objectives, which were to 1) determine requirements and strategies for sample handling and prioritization for geological operations on other planetary surfaces, 2) assess the scientific contribution of selective in-situ sample characterization for mission planning, operations, and sample prioritization, 3) evaluate analytical instruments and tools for providing efficient and meaningful data in advance of sample return and 4) identify science operations that leverage human presence with robotic tools. In the first year of tests (2010), GeoLab examined basic glovebox operations performed by one and two crewmembers and science operations performed by a remote science team. The 2010 tests also examined the efficacy of basic sample characterization [descriptions, microscopic imagery, X-ray fluorescence (XRF) analyses] and feedback to the science team. In year 2 (2011), the GeoLab team tested enhanced software and interfaces for the crew and science team (including Web-based and mobile device displays) and demonstrated laboratory configurability with a new diagnostic instrument (the Multispectral Microscopic Imager from the JPL and Arizona State University). In year 3 (2012), the GeoLab team installed and tested a robotic sample manipulator and evaluated robotic-human interfaces for science operations.

  9. Laboratory and quality assurance protocols for the analysis of herbicides in ground water from the Management Systems Evaluation Area, Princeton, Minnesota

    USGS Publications Warehouse

    Larson, S.J.; Capel, P.D.; VanderLoop, A.G.

    1996-01-01

    Laboratory and quality assurance procedures for the analysis of ground-water samples for herbicides at the Management Systems Evaluation Area near Princeton, Minnesota are described. The target herbicides include atrazine, de-ethylatrazine, de-isopropylatrazine, metribuzin, alachlor, 2,6-diethylaniline, and metolachlor. The analytical techniques used are solid-phase extraction, and analysis by gas chromatography with mass-selective detection. Descriptions of cleaning procedures, preparation of standard solutions, isolation of analytes from water, sample transfer methods, instrumental analysis, and data analysis are included.

  10. Ammonia concentrations in canine whole blood, EDTA-anticoagulated whole blood, and plasma measured by use of a point-of-care ammonia meter.

    PubMed

    Odunayo, Adesola; Tobias, Karen M; Okafor, Chika C; Flatland, Bente

    2017-11-01

    OBJECTIVE To investigate the use of canine whole blood (WB) for measurement of ammonia concentration by use of a point-of-care ammonia meter and to compare results of measuring ammonia concentrations in WB, EDTA-anticoagulated WB, and plasma. ANIMALS 40 client-owned dogs. PROCEDURES A blood sample (2 mL) was obtained from each dog. One drop of WB was immediately applied to a test strip for evaluation with an ammonia meter. The remainder of the blood sample was placed in an EDTA-containing tube, and 1 drop of EDTA-anticoagulated WB was applied to a test strip. The remaining EDTA-anticoagulated WB sample was centrifuged, and the plasma was harvested and placed on ice. One drop of plasma was applied to a test strip; the remainder of the plasma sample was transported on ice and used for ammonia measurement with a reference laboratory instrument. All samples were tested within 1 hour after sample collection. Results were evaluated to detect significant differences in ammonia concentration. RESULTS Ammonia concentrations did not differ significantly between WB and EDTA-anticoagulated WB and between plasma samples measured with the meter and reference laboratory instrument. However, median ammonia concentration was significantly higher in plasma than in WB or EDTA-anti-coagulated WB. CONCLUSIONS AND CLINICAL RELEVANCE Anticoagulant-free WB was a valid sample for measurement by use of the ammonia meter. Plasma samples had higher ammonia concentrations than did WB samples. Results for each sample type should be interpreted by use of specimen- and method-specific reference intervals.

  11. Development and psychometric properties of a theory-guided prescription stimulant misuse questionnaire for college students.

    PubMed

    Bavarian, Niloofar; Flay, Brian R; Ketcham, Patricia L; Smit, Ellen

    2013-04-01

    A theory-guided instrument for examining prescription stimulant misuse in the college population was developed and its psychometric properties were evaluated from 2011 to 2012 at one Pacific Northwest (United States) university. Study methods included instrument development, assessment by five health and measurement professionals, group interviews with six college students, a test-retest pilot study, and a paper-based, in-classroom, campus study using one-stage cluster sampling (N = 520 students, 20 classrooms, eligible student response rate = 96.30%). The instrument demonstrated reliability (i.e., internal consistency and stability) and validity (i.e., face, content, and predictive). Limitations and implications are discussed.

  12. Construction and Validation of SRA-FV Need Assessment.

    PubMed

    Thornton, David; Knight, Raymond A

    2015-08-01

    This article describes the construction and testing of a newly designed instrument to assess psychological factors associated with increased rates of sexual recidivism. The new instrument (Structured Risk Assessment-Forensic Version or SRA-FV) was based on previous research using the SRA framework. This article describes the results of testing SRA-FV with a large sample (N = 566) of sexual offenders being evaluated for an early civil commitment program. SRA-FV was found to significantly predict sexual recidivism for both child molesters and rapists and to have incremental predictive value relative to two widely used static actuarial instruments (Static-99R; Risk Matrix 2000/S). © The Author(s) 2013.

  13. Instrumental neutron activation analysis for studying size-fractionated aerosols

    NASA Astrophysics Data System (ADS)

    Salma, Imre; Zemplén-Papp, Éva

    1999-10-01

    Instrumental neutron activation analysis (INAA) was utilized for studying aerosol samples collected into a coarse and a fine size fraction on Nuclepore polycarbonate membrane filters. As a result of the panoramic INAA, 49 elements were determined in an amount of about 200-400 μg of particulate matter by two irradiations and four γ-spectrometric measurements. The analytical calculations were performed by the absolute ( k0) standardization method. The calibration procedures, application protocol and the data evaluation process are described and discussed. They make it possible now to analyse a considerable number of samples, with assuring the quality of the results. As a means of demonstrating the system's analytical capabilities, the concentration ranges, median or mean atmospheric concentrations and detection limits are presented for an extensive series of aerosol samples collected within the framework of an urban air pollution study in Budapest. For most elements, the precision of the analysis was found to be beyond the uncertainty represented by the sampling techniques and sample variability.

  14. Psychometric properties of the Brazilian version of the Personal Experience Screening Questionnaire.

    PubMed

    Fidalgo, Thiago Marques; Silveira, Evelyn Doering da; Winters, Ken C; Silveira, Dartiu Xavier da

    2016-11-01

    The Personal Experience Screening Questionnaire (PESQ) is an instrument devised for assessing the magnitude of drug misuse among adolescents. However, its psychometric properties have not been evaluated in adolescent samples outside the United States. To assess the internal reliability and validity of the Brazilian version of the PESQ. A cross-sectional study was carried out with 84 adolescents from a clinical sample and a community-based sample. All of them answered the PESQ. Among adolescents from the community, the PESQ problem severity index, which can vary from 18 to 72, was 26.48±9.28, whereas the clinical sample scored 42.89±10.02 (p<0.001). Cronbach's alpha was 0.91. Factor analysis resulted in a four-factor solution. Furthermore, both samples also had different mean scores for the other distinct content areas measured by the instrument. Evidence to support the reliability and validity of the Brazilian version of the Personal Experience Questionnaire was found.

  15. The N2N instrument to evaluate healthy work environments: an Italian validation.

    PubMed

    Palese, Alvisa; Dante, Angelo; Tonzar, Laura; Balboni, Bernardo

    2014-02-01

    The aims of the study were to (a) validate N2N Healthy Work Environment tool, (b) assess the healthiness of work environments as perceived by nurses themselves and (c) identify the factors associated with Italian nurses' perception of work environment healthiness. The linguistic and cultural adaptation of USA-N2N Healthy Work Environments was achieved through a process of forward/backward translation. Content validity was assessed by three expert nurses. The stability of the instrument was checked with a test/retest evaluation. The instrument psychometric properties, the confirmatory factor analysis as well the healthiness of the work environment and its determinant factors were evaluated with a sample of 294 nurses. The content and face validity of the N2N Healthy Work Environment instrument was confirmed. The instrument demonstrated good internal consistency (α of 0.82), excellent stability values (ρ > 0.70) and high levels of acceptability (response rate: 96.4 %). The confirmatory factor analysis has corroborated the existence of two factors as documented in the original instrument (Mays et al. in J Nurs Manag 19:18-26, 2011). Eighty-seven (29.6 %) nurses perceived the work environment where they work as "healthy". Working under a functional model of care delivery (χ(2) 24.856, p 0.000) and being responsible for one project or more (χ(2) 5.256, p 0.021) were associated with healthy environments. The instrument--valid and reliable, short in the number of items, easy to understand and based on international standards--allows a systematic assessment of the healthiness of the environment and might provide not only the opportunity to evaluate the effects of new organizational models and interventions, but also the possibility to activate a process of self-analysis and a process of ongoing review. The instrument can be used to systematically check the healthiness of Italian working environments, allowing for organizational diagnosis, targeted interventions and international comparisons.

  16. Analytical performance of benchtop total reflection X-ray fluorescence instrumentation for multielemental analysis of wine samples

    NASA Astrophysics Data System (ADS)

    Dalipi, Rogerta; Marguí, Eva; Borgese, Laura; Bilo, Fabjola; Depero, Laura E.

    2016-06-01

    Recent technological improvements have led to a widespread adoption of benchtop total reflection X-ray fluorescence systems (TXRF) for analysis of liquid samples. However, benchtop TXRF systems usually present limited sensitivity compared with high-scale instrumentation which can restrict its application in some fields. The aim of the present work was to evaluate and compare the analytical capabilities of two TXRF systems, equipped with low power Mo and W target X-ray tubes, for multielemental analysis of wine samples. Using the Mo-TXRF system, the detection limits for most elements were one order of magnitude lower than those attained using the W-TXRF system. For the detection of high Z elements like Cd and Ag, however, W-TXRF remains a very good option due to the possibility of K-Lines detection. Accuracy and precision of the obtained results have been evaluated analyzing spiked real wine samples and comparing the TXRF results with those obtained by inductively coupled plasma emission spectroscopy (ICP-OES). In general, good agreement was obtained between ICP-OES and TXRF results for the analysis of both red and white wine samples except for light elements (i.e., K) which TXRF concentrations were underestimated. However, a further achievement of analytical quality of TXRF results can be achieved if wine analysis is performed after dilution of the sample with de-ionized water.

  17. Evaluation of a Gas Chromatograph-Differential Mobility Spectrometer for Potential Water Monitoring on the International Space Station

    NASA Technical Reports Server (NTRS)

    Wallace, William T.; Limero, Thomas F.; Gazda, Daniel B.; Macatangay, Ariel V.; Dwivedi, Prabha; Fernandez, Facundo M.

    2015-01-01

    Environmental monitoring for manned spaceflight has long depended on archival sampling, which was sufficient for short missions. However, the longer mission durations aboard the International Space Station (ISS) have shown that enhanced, real-time monitoring capabilities are necessary in order to protect both the crewmembers and the spacecraft systems. Over the past several years, a number of real-time environmental monitors have been deployed on the ISS. Currently, volatile organic compounds (VOCs) in the station air are monitored by the Air Quality Monitor (AQM), a small, lightweight gas chromatograph-differential mobility spectrometer. For water monitoring, real-time monitors are used for total organic carbon (TOC) and biocide analysis. No information on the actual makeup of the TOC is provided presently, however. An improvement to the current state of environmental monitoring could be realized by modifying a single instrument to analyze both air and water. As the AQM currently provides quantitative, compound-specific information for VOCs in air samples, this instrument provides a logical starting point to evaluate the feasibility of this approach. The major hurdle for this effort lies in the liberation of the target analytes from the water matrix. In this presentation, we will discuss our recent studies, in which an electro-thermal vaporization unit has been interfaced with the AQM to analyze target VOCs at the concentrations at which they are routinely detected in archival water samples from the ISS. We will compare the results of these studies with those obtained from the instrumentation routinely used to analyze archival water samples.

  18. Developing and testing the CHORDS: Characteristics of Responsible Drinking Survey.

    PubMed

    Barry, Adam E; Goodson, Patricia

    2011-01-01

    Report on the development and psychometric testing of a theoretically and evidence-grounded instrument, the Characteristics of Responsible Drinking Survey (CHORDS). Instrument subjected to four phases of pretesting (cognitive validity, cognitive and motivational qualities, pilot test, and item evaluation) and a final posttest implementation. Large public university in Texas. Randomly selected convenience sample (n  =  729) of currently enrolled students. This 78-item questionnaire measures individuals' responsible drinking beliefs, motivations, intentions, and behaviors. Cronbach α, split-half reliability, principal components analysis and Spearman ρ were conducted to investigate reliability, stability, and validity. Measures in the CHORDS exhibited high internal consistency reliability and strong correlations of split-half reliability. Factor analyses indicated five distinct scales were present, as proposed in the theoretical model. Subscale composite scores also exhibited a correlation to alcohol consumption behaviors, indicating concurrent validity. The CHORDS represents the first instrument specifically designed to assess responsible drinking beliefs and behaviors. It was found to elicit valid and reliable data among a college student sample. This instrument holds much promise for practitioners who desire to empirically investigate dimensions of responsible drinking.

  19. Personality in sanctuary-housed chimpanzees: A comparative approach of psychobiological and penta-factorial human models.

    PubMed

    Úbeda, Yulán; Llorente, Miquel

    2015-02-18

    We evaluate a sanctuary chimpanzee sample (N = 11) using two adapted human assessment instruments: the Five-Factor Model (FFM) and Eysenck's Psychoticism-Extraversion-Neuroticism (PEN) model. The former has been widely used in studies of animal personality, whereas the latter has never been used to assess chimpanzees. We asked familiar keepers and scientists (N = 28) to rate 38 (FFM) and 12 (PEN) personality items. The personality surveys showed reliability in all of the items for both instruments. These were then analyzed in a principal component analysis and a regularized exploratory factor analysis, which revealed four and three components, respectively. The results indicate that both questionnaires show a clear factor structure, with characteristic factors not just for the species, but also for the sample type. However, due to its brevity, the PEN may be more suitable for assessing personality in a sanctuary, where employees do not have much time to devote to the evaluation process. In summary, both models are sensitive enough to evaluate the personality of a group of chimpanzees housed in a sanctuary.

  20. Evaluation of Derivative Ultraviolet Spectrometry for Determining Saccharin in Cola and Other Matrices: An Instrumental Methods Experiment.

    ERIC Educational Resources Information Center

    Stolzberg, Richard J.

    1986-01-01

    Background information and experimental procedures are provided for an experiment in which three samples of saccharin (a nickel plating solution, a dilute cola drink, and a more concentrated cola drink) are analyzed and the data interpreted using five methods. Precision and accuracy are evaluated and the best method is selected. (JN)

  1. An Evaluation of the National Teachers' Institute's Manpower Training Program for Teaching Personnel in Mid-Western Nigeria

    ERIC Educational Resources Information Center

    Osunde, A. U.; Omoruyi, F. E. O.

    2004-01-01

    This study evaluated the manpower-training program for teaching personnel in mid-western Nigeria by the National Teachers' Institute. Overall, 240 participants involved in the training program who were randomly selected from the area constituted the sample for the study. A questionnaire designed by the authors was the major instrument used for…

  2. Evaluation Methodologies: A Study to Evaluate the Functioning and Impact of the President's Council on Physical Fitness and Sports. Report No. 3.

    ERIC Educational Resources Information Center

    Bruce, Robert; And Others

    This report presents an overview of research objectives, sampling approaches, data collection procedures, and instruments and plans for analysis used in assessing the impact of the President's Council on Physical Fitness and Sports on different types of fitness programs. Surveys were conducted of: (1) community fitness programs; (2) employee…

  3. EuroFlow standardization of flow cytometer instrument settings and immunophenotyping protocols

    PubMed Central

    Kalina, T; Flores-Montero, J; van der Velden, V H J; Martin-Ayuso, M; Böttcher, S; Ritgen, M; Almeida, J; Lhermitte, L; Asnafi, V; Mendonça, A; de Tute, R; Cullen, M; Sedek, L; Vidriales, M B; Pérez, J J; te Marvelde, J G; Mejstrikova, E; Hrusak, O; Szczepański, T; van Dongen, J J M; Orfao, A

    2012-01-01

    The EU-supported EuroFlow Consortium aimed at innovation and standardization of immunophenotyping for diagnosis and classification of hematological malignancies by introducing 8-color flow cytometry with fully standardized laboratory procedures and antibody panels in order to achieve maximally comparable results among different laboratories. This required the selection of optimal combinations of compatible fluorochromes and the design and evaluation of adequate standard operating procedures (SOPs) for instrument setup, fluorescence compensation and sample preparation. Additionally, we developed software tools for the evaluation of individual antibody reagents and antibody panels. Each section describes what has been evaluated experimentally versus adopted based on existing data and experience. Multicentric evaluation demonstrated high levels of reproducibility based on strict implementation of the EuroFlow SOPs and antibody panels. Overall, the 6 years of extensive collaborative experiments and the analysis of hundreds of cell samples of patients and healthy controls in the EuroFlow centers have provided for the first time laboratory protocols and software tools for fully standardized 8-color flow cytometric immunophenotyping of normal and malignant leukocytes in bone marrow and blood; this has yielded highly comparable data sets, which can be integrated in a single database. PMID:22948490

  4. Measuring the Quality of Life of Visually Impaired Children: First Stage Psychometric Evaluation of the Novel VQoL_CYP Instrument.

    PubMed

    Tadić, Valerija; Cooper, Andrew; Cumberland, Phillippa; Lewando-Hundt, Gillian; Rahi, Jugnoo S

    2016-01-01

    To report piloting and initial validation of the VQoL_CYP, a novel age-appropriate vision-related quality of life (VQoL) instrument for self-reporting by children with visual impairment (VI). Participants were a random patient sample of children with VI aged 10-15 years. 69 patients, drawn from patient databases at Great Ormond Street Hospital and Moorfields Eye Hospital, United Kingdom, participated in piloting of the draft 47-item VQoL instrument, which enabled preliminary item reduction. Subsequent administration of the instrument, alongside functional vision (FV) and generic health-related quality of life (HRQoL) self-report measures, to 101 children with VI comprising a nationally representative sample enabled further item reduction and evaluation of psychometric properties using Rasch analysis. Construct validity was assessed through Pearson correlation coefficients. Item reduction through piloting (8 items removed for skewness and individual item response pattern) and validation (1 item removed for skewness and 3 for misfit in Rasch) produced a 35-item scale, with fit values within acceptable limits, no notable differential item functioning, good measurement precision, ordered response categories and acceptable targeting in Rasch. The VQoL_CYP showed good construct validity, correlating strongly with HRQoL scores, moderately with FV scores but not with acuity. Robust child-appropriate self-report VQoL measures for children with VI are necessary for understanding the broader impacts of living with a visual disability, distinguishing these from limited functioning per se. Future planned use in larger patient samples will allow further psychometric development of the VQoL_CYP as an adjunct to objective outcomes assessment.

  5. Content validation: clarity/relevance, reliability and internal consistency of enunciative signs of language acquisition.

    PubMed

    Crestani, Anelise Henrich; Moraes, Anaelena Bragança de; Souza, Ana Paula Ramos de

    2017-08-10

    To analyze the results of the validation of building enunciative signs of language acquisition for children aged 3 to 12 months. The signs were built based on mechanisms of language acquisition in an enunciative perspective and on clinical experience with language disorders. The signs were submitted to judgment of clarity and relevance by a sample of six experts, doctors in linguistic in with knowledge of psycholinguistics and language clinic. In the validation of reliability, two judges/evaluators helped to implement the instruments in videos of 20% of the total sample of mother-infant dyads using the inter-evaluator method. The method known as internal consistency was applied to the total sample, which consisted of 94 mother-infant dyads to the contents of the Phase 1 (3-6 months) and 61 mother-infant dyads to the contents of Phase 2 (7 to 12 months). The data were collected through the analysis of mother-infant interaction based on filming of dyads and application of the parameters to be validated according to the child's age. Data were organized in a spreadsheet and then converted to computer applications for statistical analysis. The judgments of clarity/relevance indicated no modifications to be made in the instruments. The reliability test showed an almost perfect agreement between judges (0.8 ≤ Kappa ≥ 1.0); only the item 2 of Phase 1 showed substantial agreement (0.6 ≤ Kappa ≥ 0.79). The internal consistency for Phase 1 had alpha = 0.84, and Phase 2, alpha = 0.74. This demonstrates the reliability of the instruments. The results suggest adequacy as to content validity of the instruments created for both age groups, demonstrating the relevance of the content of enunciative signs of language acquisition.

  6. An In Vitro Evaluation of Alumina, Zirconia, and Lithium Disilicate Surface Roughness Caused by Two Scaling Instruments.

    PubMed

    Vigolo, Paolo; Buzzo, Ottavia; Buzzo, Maurizio; Mutinelli, Sabrina

    2017-02-01

    Plaque control is crucial for the prevention of inflammatory periodontal disease. Hand scaling instruments have been shown to be efficient for the removal of plaque; however, routine periodontal prophylactic procedures may modify the surface profile of restorative materials. The purpose of this study was to assess in vitro the changes in roughness of alumina, zirconia, and lithium disilicate surfaces treated by two hand scaling instruments. Forty-eight alumina specimens, 48 zirconia specimens, and 48 lithium disilicate specimens, were selected. All specimens were divided into three groups of 16 each; one group for each material was considered the control group and no scaling procedures were performed; the second group of each material was exposed to scaling with steel curettes simulating standard clinical conditions; the third group of each material was exposed to scaling with titanium curettes. After scaling, the surface roughness of the specimens was evaluated with a profilometer. First, a statistical test was carried out to evaluate the difference in surface roughness before the scaling procedure of the three materials was effected (Kruskal-Wallis test). Subsequently, the effect of curette material (steel and titanium) on roughness difference and roughness ratio was analyzed throughout the entire sample and within each material group, and a nonparametric test for dependent values was conducted (Wilcoxon signed-rank test). Finally, the roughness ratios of the three material groups were compared by means of a Kruskal-Wallis test and a Wilcoxon signed-rank test. Upon completion of profilometric evaluation, representative specimens from each group were prepared for SEM evaluation to evaluate the effects of the two scaling systems on the different surfaces qualitatively. After scaling procedure, the roughness profile value increased in all disks. Classifying the full sample according to curette used, the roughness of the disks treated with a steel curette reached a higher median value than that of the titanium group. Zirconia demonstrated the least significant increase in surface roughness. The result was 3.9 times of the initial value as compared to 4.3 times for alumina and 4.6 times for lithium disilicate. Comparison of profilometer readings before and after instrumentation, carried out with different hand scaling instruments, highlighted both a statistically and clinically relevant increase in material roughness. © 2015 by the American College of Prosthodontists.

  7. Performance Evaluation of the Operational Air Quality Monitor for Water Testing Aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    Wallace, William T.; Limero, Thomas F.; Gazda, Daniel B.; Macatangay, Ariel V.; Dwivedi, Prabha; Fernandez, Facundo M.

    2014-01-01

    In the history of manned spaceflight, environmental monitoring has relied heavily on archival sampling. For short missions, this type of sample collection was sufficient; returned samples provided a snapshot of the presence of chemical and biological contaminants in the spacecraft air and water. However, with the construction of the International Space Station (ISS) and the subsequent extension of mission durations, soon to be up to one year, the need for enhanced, real-time environmental monitoring became more pressing. The past several years have seen the implementation of several real-time monitors aboard the ISS, complemented with reduced archival sampling. The station air is currently monitored for volatile organic compounds (VOCs) using gas chromatography-differential mobility spectrometry (Air Quality Monitor [AQM]). The water on ISS is analyzed to measure total organic carbon and biocide concentrations using the Total Organic Carbon Analyzer (TOCA) and the Colorimetric Water Quality Monitoring Kit (CWQMK), respectively. The current air and water monitors provide important data, but the number and size of the different instruments makes them impractical for future exploration missions. It is apparent that there is still a need for improvements in environmental monitoring capabilities. One such improvement could be realized by modifying a single instrument to analyze both air and water. As the AQM currently provides quantitative, compound-specific information for target compounds present in air samples, and many of the compounds are also targets for water quality monitoring, this instrument provides a logical starting point to evaluate the feasibility of this approach. In this presentation, we will discuss our recent studies aimed at determining an appropriate method for introducing VOCs from water samples into the gas phase and our current work, in which an electro-thermal vaporization unit has been interfaced with the AQM to analyze target analytes at the relevant concentrations at which they are routinely detected in archival water samples from the ISS.

  8. The Common Core Writing Standards: A Descriptive Study of Content and Alignment with a Sample of Former State Standards

    ERIC Educational Resources Information Center

    Troia, Gary A.; Olinghouse, Natalie G.; Wilson, Joshua; Stewart, Kelly A.; Mo, Ya; Hawkins, Lisa; Kopke, Rachel A.

    2016-01-01

    Many students do not meet expected standards of writing performance, despite the need for writing competence in and out of school. As policy instruments, writing content standards have an impact on what is taught and how students perform. This study reports findings from an evaluation of the content of a sample of seven diverse states' current…

  9. Institutional Conservation Program evaluation project: Results of elementary and secondary education survey pretest

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Collins, N.E.; Carroll, W.L.; Gaines, L.L.

    As part of a study of energy conservation efforts in schools and hospitals and an evaluation of the Institutional Conservation Program sponsored by the US Department of Energy, survey instruments that will be sent to large numbers of elementary and secondary schools and school districts were pretested. The survey instruments solicit information on energy conservation activities, decision-making processes, and energy use. The pretest had several purposes, including identification of problems in the survey instruments' formats and in the wording of instructions and questions; it also helped in establishing the sampling strategy for the survey itself. Both site visits and mailingsmore » were used in the pretest. This report covers all aspects of the pretest. Characteristics of the pretest schools, districts, and interviewees are discussed in narrative summaries. Pretest procedures are described and responses to some of the survey questions are provided.« less

  10. Evaluation of dentinal defect formation after root canal preparation with two reciprocating systems and hand instruments: an in vitro study

    PubMed Central

    Helvacioglu-Yigit, Dilek; Aydemir, Seda; Yilmaz, Ayca

    2015-01-01

    The purpose of this study was to evaluate the presence of dentinal defects after root canal preparation with hand instruments and two different reciprocating instruments. Sixty freshly extracted mandibular incisor teeth were selected for this in vitro study. On the basis of root length, mesiodistal and buccolingual dimensions, the teeth were allocated into three identical experimental groups (n = 15) and one control group (n = 15). The teeth in the control group were left unprepared. The other groups were: stainless steel hand instruments, WaveOne® Primary instruments and RECIPROC® R25 instruments. The reciprocating instruments were used with a reciprocating gentle in-and-out motion in a torque-limited electric motor at the appropriate preset mode. Horizontal sections were made 3, 6 and 9 mm from the apex. Samples were stained with methylene blue and viewed through a stereomicroscope. The presence of dentinal defects (fractures, incomplete cracks and craze lines) and their locations were investigated by two endodontists. These data were analysed statistically by Fisher's exact and chi-square tests. No defects were observed in the unprepared group. All instruments caused dentinal defects, with no significant differences between the instrument systems. All experimental groups demonstrated significantly more defects at the 3-mm level in comparison with the unprepared group (p = 0.032). At the other levels, there was no significant difference between the experimental groups and the control group. The use of hand or reciprocating instruments could induce the formation of dentinal defects during root canal preparation. PMID:26019654

  11. Instruments measuring perceived racism/racial discrimination: review and critique of factor analytic techniques.

    PubMed

    Atkins, Rahshida

    2014-01-01

    Several compendiums of instruments that measure perceived racism and/or discrimination are present in the literature. Other works have reviewed the psychometric properties of these instruments in terms of validity and reliability and have indicated if the instrument was factor analyzed. However, little attention has been given to the quality of the factor analysis performed. The aim of this study was to evaluate the exploratory factor analyses done on instruments measuring perceived racism/racial discrimination using guidelines from experts in psychometric theory. The techniques used for factor analysis were reviewed and critiqued and the adequacy of reporting was evaluated. Internet search engines and four electronic abstract databases were used to identify 16 relevant instruments that met the inclusion/exclusion criteria. Principal component analysis was the most frequent method of extraction (81%). Sample sizes were adequate for factor analysis in 81 percent of studies. The majority of studies reported appropriate criteria for the acceptance of un-rotated factors (81%) and justified the rotation method (75%). Exactly 94 percent of studies reported partially acceptable criteria for the acceptance of rotated factors. The majority of articles (69%) reported adequate coefficient alphas for the resultant subscales. In 81 percent of the studies, the conceptualized dimensions were supported by factor analysis.

  12. INSTRUMENTS MEASURING PERCEIVED RACISM/RACIAL DISCRIMINATION: REVIEW AND CRITIQUE OF FACTOR ANALYTIC TECHNIQUES

    PubMed Central

    Atkins, Rahshida

    2015-01-01

    Several compendiums of instruments that measure perceived racism and/or discrimination are present in the literature. Other works have reviewed the psychometric properties of these instruments in terms of validity and reliability and have indicated if the instrument was factor analyzed. However, little attention has been given to the quality of the factor analysis performed. The aim of this study was to evaluate the exploratory factor analyses done on instruments measuring perceived racism/racial discrimination using guidelines from experts in psychometric theory. The techniques used for factor analysis were reviewed and critiqued and the adequacy of reporting was evaluated. Internet search engines and four electronic abstract databases were used to identify 16 relevant instruments that met the inclusion/exclusion criteria. Principal component analysis was the most frequent method of extraction (81%). Sample sizes were adequate for factor analysis in 81 percent of studies. The majority of studies reported appropriate criteria for the acceptance of un-rotated factors (81%) and justified the rotation method (75%). Exactly 94 percent of studies reported partially acceptable criteria for the acceptance of rotated factors. The majority of articles (69%) reported adequate coefficient alphas for the resultant subscales. In 81 percent of the studies, the conceptualized dimensions were supported by factor analysis. PMID:25626225

  13. Root canal centering ability of rotary cutting nickel titanium instruments: A meta-analysis

    PubMed Central

    Gundappa, Mohan; Bansal, Rashmi; Khoriya, Sarvesh; Mohan, Ranjana

    2014-01-01

    Aim: To systematically review articles on canal centering ability of endodontic rotary cutting Nickel-Titanium (Ni-Ti) instruments and subject results to meta-analysis. Materials and Methods: A comprehensive search was initiated on canal centering ability of different rotary cutting Ni-Ti files such as Protaper, Hero Shaper, K3, Mtwo, Race, Wave One by selecting articles published in peer reviewed journals during 1991-2013 using “Pub Med” database. Inclusion and exclusion criteria were established. A data was created by tabulating: Author name, publication year, sample size, number of experimental groups, methods to evaluate canal centering ability, instrument cross section, taper, tip design, rake angle, mean and standard deviation. The data generated was subjected to meta-analysis. Results: Maximum studies were found to be conducted on mesiobuccal canal of mandibular 1st molar with curvature ranging from 15-60°. The difference in canal centering ability of different rotary cutting Ni-Ti instruments was not statistically significant. Conclusion: All endodontic rotary cutting Ni-Ti instruments are capable of producing centered preparations. Protaper depicted the best centering ability. Computed tomography is an effective method of evaluating canal centering ability. PMID:25506134

  14. Effect of Instrumentation Techniques, Irrigant Solutions and Artificial accelerated Aging on Fiberglass Post Bond Strength to Intraradicular Dentin.

    PubMed

    Santana, Fernanda Ribeiro; Soares, Carlos José; Silva, Júlio Almeida; Alencar, Ana Helena Gonçalves; Renovato, Sara Rodrigues; Lopes, Lawrence Gonzaga; Estrela, Carlos

    2015-07-01

    To evaluate the effect of instrumentation techniques, irrigant solutions and specimen aging on fiberglass posts bond strength to intraradicular dentine. A total of 120 bovine teeth were prepared and randomized into control and experimental groups resulting from three study factors (instrumentation techniques, irrigant solutions, specimen aging). Posts were cemented with RelyX U100. Samples were submitted to push-out test and failure mode was evaluated under a confocal microscope. In specimens submitted to water artificial aging, nickel-titanium rotary instruments group presented higher bond strength values in apical third irrigated with NaOCl or chlorhexi-dine. Irrigation with NaOCl resulted in higher bond strength than ozonated water. Artificial aging resulted in significant bond strength increase. Adhesive cement-dentin failure was prevalent in all the groups. Root canal preparation with NiTi instruments associated with NaOCl irrigation and ethylenediaminetetra acetic acid (EDTA) increased bond strength of fiberglass posts cemented with self-adhesive resin cement to intraradicular dentine. Water artificial aging significantly increased post-Clinical significance: The understanding of factors that may influence the optimal bond between post-cement and cement-dentin are essential to the success of endodontically treated tooth restoration.

  15. Skylab experiment M487 habitability/crew quarters

    NASA Technical Reports Server (NTRS)

    Johnson, C. C.

    1975-01-01

    Results of Skylab experiment M487 (habitability/crew quarters), which was designed to evaluate the habitability features of Skylab, were presented. General observations and conclusions drawn from the data obtained are presented in detail. The objectives of the experiment, the manner in which data was acquired, and the instruments used to support the experiments are described. Illustrations and photographs of the living and work areas of Skylab and some of the habitability features are provided. Samples of the subjective evaluation questionnaires used by the crewmen are included. Habitability-related documents, crewmen biographies, functional characteristics and photographs of the instruments used, and details of Skylab compartment sizes and color schemes are included as appendixes.

  16. Development of the Human Factors Skills for Healthcare Instrument: a valid and reliable tool for assessing interprofessional learning across healthcare practice settings.

    PubMed

    Reedy, Gabriel B; Lavelle, Mary; Simpson, Thomas; Anderson, Janet E

    2017-10-01

    A central feature of clinical simulation training is human factors skills, providing staff with the social and cognitive skills to cope with demanding clinical situations. Although these skills are critical to safe patient care, assessing their learning is challenging. This study aimed to develop, pilot and evaluate a valid and reliable structured instrument to assess human factors skills, which can be used pre- and post-simulation training, and is relevant across a range of healthcare professions. Through consultation with a multi-professional expert group, we developed and piloted a 39-item survey with 272 healthcare professionals attending training courses across two large simulation centres in London, one specialising in acute care and one in mental health, both serving healthcare professionals working across acute and community settings. Following psychometric evaluation, the final 12-item instrument was evaluated with a second sample of 711 trainees. Exploratory factor analysis revealed a 12-item, one-factor solution with good internal consistency (α=0.92). The instrument had discriminant validity, with newly qualified trainees scoring significantly lower than experienced trainees ( t (98)=4.88, p<0.001) and was sensitive to change following training in acute and mental health settings, across professional groups (p<0.001). Confirmatory factor analysis revealed an adequate model fit (RMSEA=0.066). The Human Factors Skills for Healthcare Instrument provides a reliable and valid method of assessing trainees' human factors skills self-efficacy across acute and mental health settings. This instrument has the potential to improve the assessment and evaluation of human factors skills learning in both uniprofessional and interprofessional clinical simulation training.

  17. Scale refinement and initial evaluation of a behavioral health function measurement tool for work disability evaluation.

    PubMed

    Marfeo, Elizabeth E; Ni, Pengsheng; Haley, Stephen M; Bogusz, Kara; Meterko, Mark; McDonough, Christine M; Chan, Leighton; Rasch, Elizabeth K; Brandt, Diane E; Jette, Alan M

    2013-09-01

    To use item response theory (IRT) data simulations to construct and perform initial psychometric testing of a newly developed instrument, the Social Security Administration Behavioral Health Function (SSA-BH) instrument, that aims to assess behavioral health functioning relevant to the context of work. Cross-sectional survey followed by IRT calibration data simulations. Community. Sample of individuals applying for Social Security Administration disability benefits: claimants (n=1015) and a normative comparative sample of U.S. adults (n=1000). None. SSA-BH measurement instrument. IRT analyses supported the unidimensionality of 4 SSA-BH scales: mood and emotions (35 items), self-efficacy (23 items), social interactions (6 items), and behavioral control (15 items). All SSA-BH scales demonstrated strong psychometric properties including reliability, accuracy, and breadth of coverage. High correlations of the simulated 5- or 10-item computer adaptive tests with the full item bank indicated robust ability of the computer adaptive testing approach to comprehensively characterize behavioral health function along 4 distinct dimensions. Initial testing and evaluation of the SSA-BH instrument demonstrated good accuracy, reliability, and content coverage along all 4 scales. Behavioral function profiles of Social Security Administration claimants were generated and compared with age- and sex-matched norms along 4 scales: mood and emotions, behavioral control, social interactions, and self-efficacy. Using the computer adaptive test-based approach offers the ability to collect standardized, comprehensive functional information about claimants in an efficient way, which may prove useful in the context of the Social Security Administration's work disability programs. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  18. Test and evaluation of the Argonne BPAC10 Series air chamber calorimeter designed for 20 minute measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perry, R.B.; Fiarman, S.; Jung, E.A.

    1990-10-01

    This paper is the final report on DOE-OSS Task ANLE88002 Fast Air Chamber Calorimetry.'' The task objective was to design, construct, and test an isothermal air chamber calorimeter for plutonium assay of bulk samples that would meet the following requirements for sample power measurement: average sample measurement time less than 20 minutes. Measurement of samples with power output up to 10 W. Precision of better than 1% RSD for sample power greater than 1 W. Precision better than 0.010 watt SD, for sample power less than 1 W. This report gives a description of the calorimeter hardware and software andmore » discusses the test results. The instrument operating procedure, included as an appendix, gives examples of typical input/output and explains the menu driven software. Sample measurement time of less than 20 minutes was attained by pre-equilibration of the samples in low cost precision preheaters and by prediction of equilibrium measurements. Tests at the TA55 Plutonium Facility at Los Alamos National Laboratory, on typical samples, indicates that the instrument meets all the measurement requirements.« less

  19. Age and education corrected older adult normative data for a short form version of the Financial Capacity Instrument.

    PubMed

    Gerstenecker, Adam; Eakin, Amanda; Triebel, Kristen; Martin, Roy; Swenson-Dravis, Dana; Petersen, Ronald C; Marson, Daniel

    2016-06-01

    Financial capacity is an instrumental activity of daily living (IADL) that comprises multiple abilities and is critical to independence and autonomy in older adults. Because of its cognitive complexity, financial capacity is often the first IADL to show decline in prodromal and clinical Alzheimer's disease and related disorders. Despite its importance, few standardized assessment measures of financial capacity exist and there is little, if any, normative data available to evaluate financial skills in the elderly. The Financial Capacity Instrument-Short Form (FCI-SF) is a brief measure of financial skills designed to evaluate financial skills in older adults with cognitive impairment. In the current study, we present age- and education-adjusted normative data for FCI-SF variables in a sample of 1344 cognitively normal, community-dwelling older adults participating in the Mayo Clinic Study of Aging (MCSA) in Olmsted County, Minnesota. Individual FCI-SF raw scores were first converted to age-corrected scaled scores based on position within a cumulative frequency distribution and then grouped within 4 empirically supported and overlapping age ranges. These age-corrected scaled scores were then converted to age- and education-corrected scaled scores using the same methodology. This study has the potential to substantially enhance financial capacity evaluations of older adults through the introduction of age- and education-corrected normative data for the FCI-SF by allowing clinicians to: (a) compare an individual's performance to that of a sample of similar age and education peers, (b) interpret various aspects of financial capacity relative to a normative sample, and (c) make comparisons between these aspects. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  20. Evaluation of a German version of a brief diagnosis questionnaire of symptoms of orthorexia nervosa in patients with mental disorders (Ortho-10).

    PubMed

    Andreas, Sylke; Schedler, Kirsten; Schulz, Holger; Nutzinger, Detlev O

    2018-02-01

    In recent years, a new term-orthorexia nervosa (ON)-has been introduced in the field of clinical assessment and psychotherapy. Orthorexia nervosa is defined as a fixation on healthy food and a pathological obsession to eat food with more natural, higher quality ingredients. Although instruments to measure ON are available, no study on the psychometric properties of the original developed instrument by Bratman (Orthorexia nervosa: Overcoming the obsession with healthful eating, Broadway Books, New York, 2000) in a large clinical sample exists until now. The study was conducted in a large clinic in Germany. The study sample consisted of N = 1122 inpatients, 70% were female, and the mean age was 41 years (SD = 14 years). The main diagnoses at the end of treatment were affective disorders (46%), followed by eating disorders (13%), anxiety disorders (10%), and personality disorders (10%). The patients filled out several instruments, like the Ortho-10, the 10-item version of the orthorexia nervosa instrument, and other construct-related, disorder-specific and construct-distant instruments. The exploratory factor analysis revealed a two-factor structure: an eating disorder-specific factor and an orthorexia-nervosa specific factor. The eating disorder factor showed good convergent and discriminative validity in which patients with eating disorders and those without could correctly be classified. However, the orthorexia-nervosa specific factor revealed no informational gain compared to the eating disorder-specific factor in this clinical sample. Further investigation is necessary to approach the concept of ON and its sense in clinical samples. Level II: evidence obtained from well-designed controlled trials without randomization.

  1. Atmospheric Electron-induced X-Ray Spectrometer (AEXS) Instrument Development

    NASA Technical Reports Server (NTRS)

    Urgiles, E.; Wilcox, J. Z.; Toda, R.; Crisp, J.; George, T.

    2005-01-01

    Introduction: This paper describes the progress in data acquisition and establishing the observational capability of the AEXS instrument. The AEXS is a miniature instrument[1-4] based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam which enables nondestructive evaluation of sample surfaces in planetary ambient atmospheres. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum of the AEXS source from the outside ambient atmosphere. Thus eliminating the need for a vacuum pumped sample chamber as is common in all laboratory SEM s. The transmitted electrons impinge on the sample exciting XRF spectra from the irradiated spot on in-situ or collected samples with sub-mm to cm-scale spatial resolution at Mars atmospheric pressure. The AEXS system (Fig 1) consists of a high-energy (>10keV) electron gun encapsulated by the isolation membrane, an XRF detection and analyzer system, and a high voltage power supply. The XRF data are analyzed to determine the elemental abundance for the irradiated spots. The approach to demonstrating a proof of concept of the AEXS has been through 1) demonstrating the viability of microfabricated membranes, 2) assembling AEXS setups with increasingly integrated functional components, and 3) simulating the AEXS observational capabilities. The development of the instrument is described in detail in the poster paper[4] at this conference. This paper focuses on describing the progress of the AEXS instrument to acquire XRF data and using commercially available software to analyze the data streams and determine the accuracy, precision and resolution of the analysis compared to the certified elemental abundance.

  2. Assessing fitness to stand trial: the utility of the Fitness Interview Test (revised edition).

    PubMed

    Zapf, P A; Roesch, R; Viljoen, J L

    2001-06-01

    In Canada most evaluations of fitness to stand trial are conducted on an inpatient basis. This costs time and money, and deprives those defendants remanded for evaluation of liberty. This research assessed the predictive efficiency of the Fitness Interview Test, revised edition (FIT) as a screening instrument for fitness to stand trial. We compared decisions about fitness to stand trial, based on the FIT, with the results of institution-based evaluations for 2 samples of men remanded for inpatient fitness assessments. The FIT demonstrates excellent utility as a screening instrument. The FIT shows good sensitivity and negative predictive power, which suggests that it can reliably screen those individuals who are clearly fit to stand trial, before they are remanded to an inpatient facility for a fitness assessment. We discuss the implications for evaluating fitness to stand trial, particularly in terms of the need for community-based alternatives to traditional forensic assessments.

  3. Psychometric properties of the Dresden Body Image Questionnaire: A multiple-group confirmatory factor analysis across sex and age in a Dutch non-clinical sample

    PubMed Central

    Scheffers, Mia; van Duijn, Marijtje A. J.; Bosscher, Ruud J.; Wiersma, Durk; Schoevers, Robert A.; van Busschbach, Jooske T.

    2017-01-01

    Background Body image has implications for psychosocial functioning and quality of life and its disturbance is reported in a broad range of psychiatric disorders. In view of the lack of instruments in Dutch measuring body image as a broad concept, we set out to make an instrument available that reflects the multidimensional character of this construct by including more dimensions than physical appearance. The Dresden Körperbildfragebogen (DBIQ, Dresden Body Image Questionnaire) particularly served this purpose. The DBIQ consists of 35 items and five subscales: body acceptance, sexual fulfillment, physical contact, vitality, and self-aggrandizement. The main objective of the present study was to evaluate the psychometric properties of the Dutch translation of the Dresden Body Image Questionnaire (DBIQ-NL) in a non-clinical sample. Methods The psychometric properties of the DBIQ-NL were examined in a non-clinical sample of 988 respondents aged between 18 and 65. We investigated the subscales' internal consistency and test-retest reliability. In order to establish construct validity we evaluated the association with a related construct, body cathexis, and with indices of self-esteem and psychological wellbeing. The factor structure of the DBIQ-NL was examined via confirmatory factor analysis (CFA). The equivalence of the measurement model across sex and age was evaluated by multiplegroup confirmatory factor analyses. Results Confirmatory factor analyses showed a structure in accordance with the original scale, where model fit was improved significantly by moving one item to another subscale. Multiple group confirmatory factor analysis across sex and age demonstrated partial strong invariance. Internal consistency was good with little overlap between the subscales. Temporal reliability and construct validity were satisfactory. Conclusion Results indicate that the DBIQ-NL is a reliable and valid instrument for non-clinical subjects. This provides a sound basis for further investigation of the DBIQ-NL in a clinical sample. PMID:28746387

  4. Detection of Reduced Nitrogen Compounds at Rocknest Using the Sample Analysis At Mars (SAM) Instrument on the Mars Science Laboratory (MSL)

    NASA Technical Reports Server (NTRS)

    Stern, J. C.; Steele, A.; Brunner, A.; Coll, P.; Eigenbrode, J.; Franz, H. B.; Freissinet, C.; Glavin, D.; Jones, J. H.; Navarro-Gonzalez, R.; hide

    2013-01-01

    The Sample Analysis at Mars (SAM) instrument suite on the Mars Science Laboratory (MSL) Curiosity Rover detected nitrogen-bearing compounds during the pyrolysis of Rocknest material at Gale Crater. Hydrogen cyanide and acetonitrile were identified by the quadrupole mass spectrometer (QMS) both in direct evolved gas analysis (EGA). SAM carried out four separate analyses from Rocknest Scoop 5. A significant low temperature release was present in Rocknest runs 1-4, while a smaller high temperature release was also seen in Rocknest runs 1-3. Here we evaluate whether these compounds are indigenous to Mars or a pyrolysis product resulting from known terrestrial materials that are part of the SAM derivatization.

  5. Shared decision making in Swedish community mental health services - an evaluation of three self-reporting instruments.

    PubMed

    Rosenberg, David; Schön, Ulla-Karin; Nyholm, Maria; Grim, Katarina; Svedberg, Petra

    2017-04-01

    Despite the potential impact of shared decision making on users satisfaction with care and quality in health care decisions, there is a lack of knowledge and skills regarding how to work with shared decision making among health care providers. The aim of this study was to evaluate the psychometric properties of three instruments that measure varied dimensions of shared decision making, based on self-reports by clients, in a Swedish community mental health context. The study sample consisted of 121 clients with experience of community mental health care, and involved in a wide range of decisions regarding both social support and treatment. The questionnaires were examined for face and content validity, internal consistency, test-retest reliability and construct validity. The instruments displayed good face and content validity, satisfactory internal consistency and a moderate to good level of stability in test-retest reliability with fair to moderate construct correlations, in a sample of clients with serious mental illness and experience of community mental health services in Sweden. The questionnaires are considered to be relevant to the decision making process, user-friendly and appropriate in a Swedish community mental health care context. They functioned well in settings where non-medical decisions, regarding social and support services, are the primary focus. The use of instruments that measure various dimensions of the self-reported experience of clients, can be a key factor in developing knowledge of how best to implement shared decision making in mental health services.

  6. [The CAD-S, an instrument for the assessment of adaptation to divorce - separation].

    PubMed

    Yárnoz Yaben, Sagrario; Comino González, Priscila

    2010-02-01

    The CAD-S, an Instrument for the Assessment of Adaptation to Divorce - Separation. This paper presents an instrument for the evaluation of the adaptation to divorce-separation. The CAD-S is a questionnaire created in Spanish, made up of 20 items whose aim is the evaluation of the family's adaptation to divorce-separation, using one of the parents as informant. Data were collected in four different samples of divorced persons and their children from different autonomous comunities from the Spanish state. 223 parents and 160 children from divorced families took part in this study. Four factors emerged, accounting for 52.39 percent of the total variance: psychological and emotional difficulties, conflict with the ex-partner, disposition to co-parentality, and negative outcomes of separation for children. The results suggest that CAD-S appears to be a reliable and valid instrument, with high internal consistency (Cronbach's alpha) and adequate construct validity supported by its relations with measures of satisfaction with life (SWLS), in the case of parents, and conduct problems (CBCL) for children.

  7. The Detection of Evolved Oxygen from the Rocknest Eolian Bedform Material by the Sample Analysis at Mars(SAM) instrument at the Mars Curiosity Landing Site

    NASA Technical Reports Server (NTRS)

    Sutter, B.; Archer, D.; Ming, D.; Eigenbrode, J. L.; Franz, H.; Glavin, D. P.; McAdam, A.; Mahaffy, P.; Stern, J.; Navarro-Gonzalex, R.; hide

    2013-01-01

    The Sample Analysis at Mars (SAM) instrument onboard the Curiosity rover detected an O2 gas release from the Rocknest eolain bedform (Fig. 1). The detection of perchlorate (ClO4-) by the Mars Phoenix Lander s Wet Chemistry Laboratory (WCL) [1] suggests that perchlorate is a possible candidate for evolved O2 release detected by SAM. The perchlorate would also serve as a source of chlorine in the chlorinated hydrocarbons detected by the SAM quadrupole mass spectrometer (QMS) and gas chromatography/mass spectrometer (GCMS) [2,3]. Chlorates (ClO3-) [4,5] and/or superoxides [6] may also be sources of evolved O2 from the Rocknest materials. The work objectives are to 1) evaluate the O2 release temperatures from Rocknest materials, 2) compare these O2 release temperatures with a series of perchlorates and chlorates, and 3) evaluate superoxide O2- sources and possible perchlorate interactions with other Rocknest phases during QMS analysis.

  8. Wine industry residues extracts as natural antioxidants in raw and cooked chicken meat during frozen storage.

    PubMed

    Selani, M M; Contreras-Castillo, C J; Shirahigue, L D; Gallo, C R; Plata-Oviedo, M; Montes-Villanueva, N D

    2011-07-01

    The effect of Isabel (IGE) and Niagara (NGE) grape seed and peel extracts on lipid oxidation, instrumental colour, pH and sensory properties of raw and cooked processed chicken meat stored at -18°C for nine months was evaluated. The pH of raw and cooked samples was not affected by the addition of grape extracts. IGE and NGE were effective in inhibiting the lipid oxidation of raw and cooked chicken meat, with results comparable to synthetic antioxidants. The extracts caused alterations in colour, as evidenced by the instrumental (darkening and lower intensity of red and yellow colour) and sensory results of cooked samples. In the sensory evaluation of odour and flavour, IGE produced satisfactory results, which did not differ from synthetic antioxidants. These findings suggest that the IGE and NGE are effective in retarding lipid oxidation of raw and cooked chicken meat during frozen storage. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Outcomes of Moral Case Deliberation - the development of an evaluation instrument for clinical ethics support (the Euro-MCD)

    PubMed Central

    2014-01-01

    Background Clinical ethics support, in particular Moral Case Deliberation, aims to support health care providers to manage ethically difficult situations. However, there is a lack of evaluation instruments regarding outcomes of clinical ethics support in general and regarding Moral Case Deliberation (MCD) in particular. There also is a lack of clarity and consensuses regarding which MCD outcomes are beneficial. In addition, MCD outcomes might be context-sensitive. Against this background, there is a need for a standardised but flexible outcome evaluation instrument. The aim of this study was to develop a multi-contextual evaluation instrument measuring health care providers’ experiences and perceived importance of outcomes of Moral Case Deliberation. Methods A multi-item instrument for assessing outcomes of Moral Case Deliberation (MCD) was constructed through an iterative process, founded on a literature review and modified through a multistep review by ethicists and health care providers. The instrument measures perceived importance of outcomes before and after MCD, as well as experienced outcomes during MCD and in daily work. A purposeful sample of 86 European participants contributed to a Delphi panel and content validity testing. The Delphi panel (n = 13), consisting of ethicists and ethics researchers, participated in three Delphi-rounds. Health care providers (n = 73) participated in the content validity testing through ‘think-aloud’ interviews and a method using Content Validity Index. Results The development process resulted in the European Moral Case Deliberation Outcomes Instrument (Euro-MCD), which consists of two sections, one to be completed before a participant’s first MCD and the other after completing multiple MCDs. The instrument contains a few open-ended questions and 26 specific items with a corresponding rating/response scale representing various MCD outcomes. The items were categorised into the following six domains: Enhanced emotional support, Enhanced collaboration, Improved moral reflexivity, Improved moral attitude, Improvement on organizational level and Concrete results. Conclusions A tentative instrument has been developed that seems to cover main outcomes of Moral Case Deliberation. The next step will be to test the Euro-MCD in a field study. PMID:24712735

  10. Outcomes of moral case deliberation--the development of an evaluation instrument for clinical ethics support (the Euro-MCD).

    PubMed

    Svantesson, Mia; Karlsson, Jan; Boitte, Pierre; Schildman, Jan; Dauwerse, Linda; Widdershoven, Guy; Pedersen, Reidar; Huisman, Martijn; Molewijk, Bert

    2014-04-08

    Clinical ethics support, in particular Moral Case Deliberation, aims to support health care providers to manage ethically difficult situations. However, there is a lack of evaluation instruments regarding outcomes of clinical ethics support in general and regarding Moral Case Deliberation (MCD) in particular. There also is a lack of clarity and consensuses regarding which MCD outcomes are beneficial. In addition, MCD outcomes might be context-sensitive. Against this background, there is a need for a standardised but flexible outcome evaluation instrument. The aim of this study was to develop a multi-contextual evaluation instrument measuring health care providers' experiences and perceived importance of outcomes of Moral Case Deliberation. A multi-item instrument for assessing outcomes of Moral Case Deliberation (MCD) was constructed through an iterative process, founded on a literature review and modified through a multistep review by ethicists and health care providers. The instrument measures perceived importance of outcomes before and after MCD, as well as experienced outcomes during MCD and in daily work. A purposeful sample of 86 European participants contributed to a Delphi panel and content validity testing. The Delphi panel (n = 13), consisting of ethicists and ethics researchers, participated in three Delphi-rounds. Health care providers (n = 73) participated in the content validity testing through 'think-aloud' interviews and a method using Content Validity Index. The development process resulted in the European Moral Case Deliberation Outcomes Instrument (Euro-MCD), which consists of two sections, one to be completed before a participant's first MCD and the other after completing multiple MCDs. The instrument contains a few open-ended questions and 26 specific items with a corresponding rating/response scale representing various MCD outcomes. The items were categorised into the following six domains: Enhanced emotional support, Enhanced collaboration, Improved moral reflexivity, Improved moral attitude, Improvement on organizational level and Concrete results. A tentative instrument has been developed that seems to cover main outcomes of Moral Case Deliberation. The next step will be to test the Euro-MCD in a field study.

  11. Challenges of biological sample preparation for SIMS imaging of elements and molecules at subcellular resolution

    NASA Astrophysics Data System (ADS)

    Chandra, Subhash

    2008-12-01

    Secondary ion mass spectrometry (SIMS) based imaging techniques capable of subcellular resolution characterization of elements and molecules are becoming valuable tools in many areas of biology and medicine. Due to high vacuum requirements of SIMS, the live cells cannot be analyzed directly in the instrument. The sample preparation, therefore, plays a critical role in preserving the native chemical composition for SIMS analysis. This work focuses on the evaluation of frozen-hydrated and frozen freeze-dried sample preparations for SIMS studies of cultured cells with a CAMECA IMS-3f dynamic SIMS ion microscope instrument capable of producing SIMS images with a spatial resolution of 500 nm. The sandwich freeze-fracture method was used for fracturing the cells. The complimentary fracture planes in the plasma membrane were characterized by field-emission secondary electron microscopy (FESEM) in the frozen-hydrated state. The cells fractured at the dorsal surface were used for SIMS analysis. The frozen-hydrated SIMS analysis of individual cells under dynamic primary ion beam (O 2+) revealed local secondary ion signal enhancements correlated with the water image signals of 19(H 3O) +. A preferential removal of water from the frozen cell matrix in the Z-axis was also observed. These complications render the frozen-hydrated sample type less desirable for subcellular dynamic SIMS studies. The freeze-drying of frozen-hydrated cells, either inside the instrument or externally in a freeze-drier, allowed SIMS imaging of subcellular chemical composition. Morphological evaluations of fractured freeze-dried cells with SEM and confocal laser scanning microscopy (CLSM) revealed well-preserved mitochondria, Golgi apparatus, and stress fibers. SIMS analysis of fractured freeze-dried cells revealed well-preserved chemical composition of even the most highly diffusible ions like K + and Na + in physiologically relevant concentrations. The high K-low Na signature in individual cells provided a rule-of-thumb criterion for the validation of sample preparation. The fractured freeze-dried cells allowed 3-D SIMS imaging and localization of 13C 15N labeled molecules and therapeutic drugs containing an elemental tag. Examples are shown to demonstrate that both diffusible elements and molecules are prone to artifact-induced relocation at subcellular scale if the sample preparation is compromised. The sample preparation is problem dependent and may vary widely between the diverse sample types of biological systems and the type of instrument used for SIMS analysis. The sample preparation, however, must be validated so that SIMS can be applied with confidence in biology and medicine.

  12. Modification of the BAX Salmonella test kit to include a hot start functionality (modification of AOAC Official Method 2003.09).

    PubMed

    Wallace, F Morgan; DiCosimo, Deana; Farnum, Andrew; Tice, George; Andaloro, Bridget; Davis, Eugene; Burns, Frank R

    2011-01-01

    In 2010, the BAX System PCR assay for Salmonella was modified to include a hot start functionality designed to keep the reaction enzyme inactive until PCR begins. To validate the assay's Official Methods of Analysis status to include this procedure modification, an evaluation was conducted on four food types that were simultaneously analyzed with the BAX System and either the U.S. Food and Drug Administration's Bacteriological Analytical Manual or the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook reference method for detecting Salmonella. Identical performance between the BAX System method and the reference methods was observed. Additionally, lysates were analyzed using both the BAX System Classic and BAX System Q7 instruments with identical results using both platforms for all samples tested. Of the 100 samples analyzed, 34 samples were positive for both the BAX System and reference methods, and 66 samples were negative by both the BAX System and reference methods, demonstrating 100% correlation. No instrument platform variation was observed. Additional inclusivity and exclusivity testing using the modified test kit demonstrated the test kit to be 100% accurate in evaluation of test panels of 352 Salmonella strains and 46 non-Salmonella strains.

  13. Regularization Methods for High-Dimensional Instrumental Variables Regression With an Application to Genetical Genomics

    PubMed Central

    Lin, Wei; Feng, Rui; Li, Hongzhe

    2014-01-01

    In genetical genomics studies, it is important to jointly analyze gene expression data and genetic variants in exploring their associations with complex traits, where the dimensionality of gene expressions and genetic variants can both be much larger than the sample size. Motivated by such modern applications, we consider the problem of variable selection and estimation in high-dimensional sparse instrumental variables models. To overcome the difficulty of high dimensionality and unknown optimal instruments, we propose a two-stage regularization framework for identifying and estimating important covariate effects while selecting and estimating optimal instruments. The methodology extends the classical two-stage least squares estimator to high dimensions by exploiting sparsity using sparsity-inducing penalty functions in both stages. The resulting procedure is efficiently implemented by coordinate descent optimization. For the representative L1 regularization and a class of concave regularization methods, we establish estimation, prediction, and model selection properties of the two-stage regularized estimators in the high-dimensional setting where the dimensionality of co-variates and instruments are both allowed to grow exponentially with the sample size. The practical performance of the proposed method is evaluated by simulation studies and its usefulness is illustrated by an analysis of mouse obesity data. Supplementary materials for this article are available online. PMID:26392642

  14. Microbiological evaluation of the steam sterilization of assembled laparoscopic instruments 1

    PubMed Central

    de Camargo, Tamara Carolina; Graziano, Kazuko Uchikawa; Almeida, Alda Graciele Claudio dos Santos; Suzuki, Karina; da Silva, Cely Barreto; Pinto, Flávia Morais Gomes

    2016-01-01

    ABSTRACT Objective: assess the safety of steam sterilization of assembled laparoscopic instruments with challenge contamination. Method: a laboratory experimental study, using as test samples trocars and laparoscopic graspers. Geobacillus stearothermophillus ATCC-7953 was used, with a microbial population of 106UFC/Filter paper substrate, removed from the biological indicator. Three of them were introduced into each instrument at the time of assembly, and sterilized at pressurized saturated steam, 134oC for 5 minutes. After sterilization, the instrument was disassembled and each filter paper substrate was inoculated in soybean casein culture and incubated at 56oC for 21 days. In case of absence of growth, they were subjected to heat shock of 80oC, for 20 minutes and re-incubated for 72 hours. Sample size: 185 graspers and 185 trocars, with 95% power. We paired the experiments with comparative negative control groups (5 graspers and 5 trocars with challenge contamination, sterilized disassembled) and positive control (30 filter paper supports, unsterilized), subject to the same incubation procedures. Results: there was no microbial growth in experimental and negative control. The results of the positive control were satisfactory. Conclusion: this study provided strong scientific evidence to support the safety of steam sterilizing of the assembled laparoscopic instrument. PMID:27878222

  15. An intercomparison of airborne nitric oxide measurements - A second opportunity

    NASA Technical Reports Server (NTRS)

    Gregory, Gerald L.; Hoell, James M., Jr.; Torres, Arnold L.; Carroll, Mary Anne; Ridley, Brian A.

    1990-01-01

    Results are reported from a comparison of three tropospheric NO measurement instruments during the NASA Global Tropospheric Experiment Chemical Instrumentation Test and Evaluation 2 (CITE 2) in summer 1986. The instruments tested were those used in CITE 1 (Hoell et al., 1987): a two-photon LIF system and two chemiluminescence systems. It is found that the mixing ratios obtained with the three systems agreed to within 15-20 parts per trillion volume (pptv) for sampling perods of 1-6 min at mixing ratios less than 20 pptv; the average difference between pairs of measurements was 5-7 pptv, which is considered to be the uncertainty in state-of-the-art ambient NO measurements.

  16. Infection Control in Retreatment Cases: In Vivo Antibacterial Effects of 2 Instrumentation Systems.

    PubMed

    Rodrigues, Renata C V; Antunes, Henrique S; Neves, Mônica A S; Siqueira, José F; Rôças, Isabela N

    2015-10-01

    This in vivo study compared the antibacterial effects of 2 instrumentation systems in root canal-treated teeth with apical periodontitis. Forty-eight teeth with a single root and a single canal showing post-treatment apical periodontitis were selected for this study. For retreatment, teeth were randomly divided into 2 groups according to the instrumentation system used: Self-Adjusting File (SAF; ReDent-Nova, Ra'anana, Israel) and Twisted File Adaptive (TFA; SybronEndo, Orange, CA). In both groups, 2.5% sodium hypochlorite was the irrigant. Bacteriological samples were taken before (S1) and after chemomechanical preparation (S2). In the TFA group, passive ultrasonic irrigation (PUI) was performed after instrumentation, and samples were also taken after this supplementary step (S2b). DNA was extracted from the clinical samples and subjected to quantitative real-time polymerase chain reaction to evaluate the levels of total bacteria, streptococci, and Enterococcus faecalis. Statistical analyses from quantitative real-time polymerase chain reaction data were performed within groups using the Wilcoxon matched pairs test and between groups using the Mann-Whitney U test and the Fisher exact test with the significance level set at P < .05. Bacteria were detected in S1 samples from 43 teeth, which were then included in the antibacterial experiment. Both SAF and TFA instrumentation protocols showed a highly significant intracanal bacterial reduction (P < .001). Intergroup quantitative comparisons disclosed no significant differences between TFA with or without PUI and SAF (P > .05). PUI did not result in significant improvement in disinfection (P > .05). Both instrumentation systems/treatment protocols were highly effective in significantly reducing the intracanal bacterial counts. No significant difference was observed between the 2 systems in disinfecting the canals of teeth with post-treatment apical periodontitis. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  17. Two stage algorithm vs commonly used approaches for the suspect screening of complex environmental samples analyzed via liquid chromatography high resolution time of flight mass spectroscopy: A test study.

    PubMed

    Samanipour, Saer; Baz-Lomba, Jose A; Alygizakis, Nikiforos A; Reid, Malcolm J; Thomaidis, Nikolaos S; Thomas, Kevin V

    2017-06-09

    LC-HR-QTOF-MS recently has become a commonly used approach for the analysis of complex samples. However, identification of small organic molecules in complex samples with the highest level of confidence is a challenging task. Here we report on the implementation of a two stage algorithm for LC-HR-QTOF-MS datasets. We compared the performances of the two stage algorithm, implemented via NIVA_MZ_Analyzer™, with two commonly used approaches (i.e. feature detection and XIC peak picking, implemented via UNIFI by Waters and TASQ by Bruker, respectively) for the suspect analysis of four influent wastewater samples. We first evaluated the cross platform compatibility of LC-HR-QTOF-MS datasets generated via instruments from two different manufacturers (i.e. Waters and Bruker). Our data showed that with an appropriate spectral weighting function the spectra recorded by the two tested instruments are comparable for our analytes. As a consequence, we were able to perform full spectral comparison between the data generated via the two studied instruments. Four extracts of wastewater influent were analyzed for 89 analytes, thus 356 detection cases. The analytes were divided into 158 detection cases of artificial suspect analytes (i.e. verified by target analysis) and 198 true suspects. The two stage algorithm resulted in a zero rate of false positive detection, based on the artificial suspect analytes while producing a rate of false negative detection of 0.12. For the conventional approaches, the rates of false positive detection varied between 0.06 for UNIFI and 0.15 for TASQ. The rates of false negative detection for these methods ranged between 0.07 for TASQ and 0.09 for UNIFI. The effect of background signal complexity on the two stage algorithm was evaluated through the generation of a synthetic signal. We further discuss the boundaries of applicability of the two stage algorithm. The importance of background knowledge and experience in evaluating the reliability of results during the suspect screening was evaluated. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Development and Psychometric Evaluation of an Instrument to Assess Cross-Cultural Competence of Healthcare Professionals (CCCHP)

    PubMed Central

    Bernhard, Gerda; Knibbe, Ronald A.; von Wolff, Alessa; Dingoyan, Demet; Schulz, Holger; Mösko, Mike

    2015-01-01

    Background Cultural competence of healthcare professionals (HCPs) is recognized as a strategy to reduce cultural disparities in healthcare. However, standardised, valid and reliable instruments to assess HCPs’ cultural competence are notably lacking. The present study aims to 1) identify the core components of cultural competence from a healthcare perspective, 2) to develop a self-report instrument to assess cultural competence of HCPs and 3) to evaluate the psychometric properties of the new instrument. Methods The conceptual model and initial item pool, which were applied to the cross-cultural competence instrument for the healthcare profession (CCCHP), were derived from an expert survey (n = 23), interviews with HCPs (n = 12), and a broad narrative review on assessment instruments and conceptual models of cultural competence. The item pool was reduced systematically, which resulted in a 59-item instrument. A sample of 336 psychologists, in advanced psychotherapeutic training, and 409 medical students participated, in order to evaluate the construct validity and reliability of the CCCHP. Results Construct validity was supported by principal component analysis, which led to a 32-item six-component solution with 50% of the total variance explained. The different dimensions of HCPs’ cultural competence are: Cross-Cultural Motivation/Curiosity, Cross-Cultural Attitudes, Cross-Cultural Skills, Cross-Cultural Knowledge/Awareness and Cross-Cultural Emotions/Empathy. For the total instrument, the internal consistency reliability was .87 and the dimension’s Cronbach’s α ranged from .54 to .84. The discriminating power of the CCCHP was indicated by statistically significant mean differences in CCCHP subscale scores between predefined groups. Conclusions The 32-item CCCHP exhibits acceptable psychometric properties, particularly content and construct validity to examine HCPs’ cultural competence. The CCCHP with its five dimensions offers a comprehensive assessment of HCPs’ cultural competence, and has the ability to distinguish between groups that are expected to differ in cultural competence. This instrument can foster professional development through systematic self-assessment and thus contributes to improve the quality of patient care. PMID:26641876

  19. Development and Psychometric Evaluation of an Instrument to Assess Cross-Cultural Competence of Healthcare Professionals (CCCHP).

    PubMed

    Bernhard, Gerda; Knibbe, Ronald A; von Wolff, Alessa; Dingoyan, Demet; Schulz, Holger; Mösko, Mike

    2015-01-01

    Cultural competence of healthcare professionals (HCPs) is recognized as a strategy to reduce cultural disparities in healthcare. However, standardised, valid and reliable instruments to assess HCPs' cultural competence are notably lacking. The present study aims to 1) identify the core components of cultural competence from a healthcare perspective, 2) to develop a self-report instrument to assess cultural competence of HCPs and 3) to evaluate the psychometric properties of the new instrument. The conceptual model and initial item pool, which were applied to the cross-cultural competence instrument for the healthcare profession (CCCHP), were derived from an expert survey (n = 23), interviews with HCPs (n = 12), and a broad narrative review on assessment instruments and conceptual models of cultural competence. The item pool was reduced systematically, which resulted in a 59-item instrument. A sample of 336 psychologists, in advanced psychotherapeutic training, and 409 medical students participated, in order to evaluate the construct validity and reliability of the CCCHP. Construct validity was supported by principal component analysis, which led to a 32-item six-component solution with 50% of the total variance explained. The different dimensions of HCPs' cultural competence are: Cross-Cultural Motivation/Curiosity, Cross-Cultural Attitudes, Cross-Cultural Skills, Cross-Cultural Knowledge/Awareness and Cross-Cultural Emotions/Empathy. For the total instrument, the internal consistency reliability was .87 and the dimension's Cronbach's α ranged from .54 to .84. The discriminating power of the CCCHP was indicated by statistically significant mean differences in CCCHP subscale scores between predefined groups. The 32-item CCCHP exhibits acceptable psychometric properties, particularly content and construct validity to examine HCPs' cultural competence. The CCCHP with its five dimensions offers a comprehensive assessment of HCPs' cultural competence, and has the ability to distinguish between groups that are expected to differ in cultural competence. This instrument can foster professional development through systematic self-assessment and thus contributes to improve the quality of patient care.

  20. Determination and distribution of rare earth elements in beach rock samples using instrumental neutron activation analysis (INAA)

    NASA Astrophysics Data System (ADS)

    Ravisankar, R.; Manikandan, E.; Dheenathayalu, M.; Rao, Brahmaji; Seshadreesan, N. P.; Nair, K. G. M.

    2006-10-01

    Beach rocks are a peculiar type of formation when compared to other types of rocks. Rare earth element (REE) concentrations in beach rock samples collected from the South East Coast of Tamilnadu, India, have been measured using the instrumental neutron activation analysis (INAA) single comparator K0 method. The irradiations were carried out using a thermal neutron flux of ˜10 11 n cm -2 s -1 at 20 kW power using the Kalpakkam mini reactor (KAMINI), IGCAR, Kalpakkam, Tamilnadu. Accuracy and precision were evaluated by assaying irradiated standard reference material (SRM 1646a estuarine sediment). The results being found to be in good agreement with certified values. REE elements have been determined from 15 samples using high-resolution gamma spectrometry. The geochemical behavior of REE in beach rock, in particular REE (chondrite-normalized) pattern has been studied.

  1. Search for organic matter at Mars with combined measurements of the SAM and ChemCam instruments onboard the Curiosity rover

    NASA Astrophysics Data System (ADS)

    Dequaire, T.; Meslin, P. Y.; Rapin, W.; Jaber, M.; Maurice, S.; Gasnault, O.; Forni, O.; Coll, P.; Szopa, C.

    2015-10-01

    Since 2012, he Curiosity rover on Mars seeks clues of habitability in Gale crater. One of these clues is the presence of organic matter. For the moment,only a few traces of organic matter was recently found with the SAM experiment. We propose here to evaluate the capabilities for the ChemCam experiment to detect organic molecules from its elemental analysis of the Mars regolith or rocks. The first results obtained in laboratory with the ChemCam spare model and different samples show that it is possible to detect organic signatures with LIBS,focusing on atomic carbon, hydrogen and nitrogen peaks,and on a C-N molecular peak when the samples areenriched in organic molecules(100-10 wt%). We currently work with Mars representative samples to determine the instrument detection limitfor organics, in order to determine if it can be used to guide Curiosity towards interesting outcrops.

  2. Asymmetric flow field flow fractionation with light scattering detection - an orthogonal sensitivity analysis.

    PubMed

    Galyean, Anne A; Filliben, James J; Holbrook, R David; Vreeland, Wyatt N; Weinberg, Howard S

    2016-11-18

    Asymmetric flow field flow fractionation (AF 4 ) has several instrumental factors that may have a direct effect on separation performance. A sensitivity analysis was applied to ascertain the relative importance of AF 4 primary instrument factor settings for the separation of a complex environmental sample. The analysis evaluated the impact of instrumental factors namely, cross flow, ramp time, focus flow, injection volume, and run buffer concentration on the multi-angle light scattering measurement of natural organic matter (NOM) molar mass (MM). A 2 (5-1) orthogonal fractional factorial design was used to minimize analysis time while preserving the accuracy and robustness in the determination of the main effects and interactions between any two instrumental factors. By assuming that separations resulting in smaller MM measurements would be more accurate, the analysis produced a ranked list of effects estimates for factors and interactions of factors based on their relative importance in minimizing the MM. The most important and statistically significant AF 4 instrumental factors were buffer concentration and cross flow. The least important was ramp time. A parallel 2 (5-2) orthogonal fractional factorial design was also employed on five environmental factors for synthetic natural water samples containing silver nanoparticles (NPs), namely: NP concentration, NP size, NOM concentration, specific conductance, and pH. None of the water quality characteristic effects or interactions were found to be significant in minimizing the measured MM; however, the interaction between NP concentration and NP size was an important effect when considering NOM recovery. This work presents a structured approach for the rigorous assessment of AF 4 instrument factors and optimal settings for the separation of complex samples utilizing efficient orthogonal factional factorial design and appropriate graphical analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. A Customizable Flow Injection System for Automated, High Throughput, and Time Sensitive Ion Mobility Spectrometry and Mass Spectrometry Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orton, Daniel J.; Tfaily, Malak M.; Moore, Ronald J.

    To better understand disease conditions and environmental perturbations, multi-omic studies (i.e. proteomic, lipidomic, metabolomic, etc. analyses) are vastly increasing in popularity. In a multi-omic study, a single sample is typically extracted in multiple ways and numerous analyses are performed using different instruments. Thus, one sample becomes many analyses, making high throughput and reproducible evaluations a necessity. One way to address the numerous samples and varying instrumental conditions is to utilize a flow injection analysis (FIA) system for rapid sample injection. While some FIA systems have been created to address these challenges, many have limitations such as high consumable costs, lowmore » pressure capabilities, limited pressure monitoring and fixed flow rates. To address these limitations, we created an automated, customizable FIA system capable of operating at diverse flow rates (~50 nL/min to 500 µL/min) to accommodate low- and high-flow instrument sources. This system can also operate at varying analytical throughputs from 24 to 1200 samples per day to enable different MS analysis approaches. Applications ranging from native protein analyses to molecular library construction were performed using the FIA system. The results from these studies showed a highly robust platform, providing consistent performance over many days without carryover as long as washing buffers specific to each molecular analysis were utilized.« less

  4. Psychometric Evaluation of the Summary of Diabetes Self-Care Activities-Arabic (SDSCA-Arabic): Translation and Analysis Process.

    PubMed

    AlJohani, Khalid A; Kendall, Garth E; Snider, Paul D

    2016-01-01

    To translate and examine the psychometric properties of the Arabic version of the Summary of Diabetes Self-Care Activities. An instrument translation and validation study. A total of 243 participants (33 first sample and 210 second sample) diagnosed with type 2 diabetes mellitus were recruited from four primary health care centers in Saudi Arabia. The study was guided by the World Health Organization guidelines for translation and validation of instrument. Translation indicators showed satisfactory outcomes for each included process in the forward-translation, an expert panel, and back-translation stages. Reliability and validity outcomes were as follows: test-retest, r = .912 and p < .001; split-half = .9; and Cronbach's alpha (α) = .76. The alpha scores for the subscales were as follows: diet, .89; exercise, .83; blood glucose testing, .92; and foot care, .77. Principal component analysis revealed the presence of four components with eigenvalues greater than 1.0, explaining 34.4, 16.4, 15.4, and 11.2% of the variance in everyday practices for these items, respectively (accumulated = 77.1%). The translation and validation processes revealed acceptable psychometric properties. The instrument could evaluate diabetes self-care in Saudi Arabia and has the potential to be used in other Arabic-speaking populations. © The Author(s) 2014.

  5. Breath alcohol, multisensor arrays, and electronic noses

    NASA Astrophysics Data System (ADS)

    Paulsson, Nils; Winquist, Fredrik

    1997-01-01

    The concept behind a volatile compound mapper, or electronic nose, is to use the combination of multiple gas sensors and pattern recognition techniques to detect and quantify substances in gas mixtures. There are several different kinds of sensors which have been developed during recent years of which the base techniques are conducting polymers, piezo electrical crystals and solid state devices. In this work we have used a combination of gas sensitive field effect devices and semiconducting metal oxides. The most useful pattern recognition routine was found to be ANNs, which is a mathematical approximation of the human neural network. The aim of this work is to evaluate the possibility of using electronic noses in field instruments to detect drugs, arson residues, explosives etc. As a test application we have chosen breath alcohol measurements. There are several reasons for this. Breath samples are a quite complex mixture contains between 200 and 300 substances at trace levels. The alcohol level is low but still possible to handle. There are needs for replacing large and heavy mobile instruments with smaller devices. Current instrumentation is rather sensitive to interfering substances. The work so far has dealt with sampling, how to introduce ethanol and other substances in the breath, correlation measurements between the electronic nose and headspace GC, and how to evaluate the sensor signals.

  6. Mars Sample Return: The Next Step Required to Revolutionize Knowledge of Martian Geological and Climatological History

    NASA Technical Reports Server (NTRS)

    Mittlefehldt, D. W.

    2012-01-01

    The capability of scientific instrumentation flown on planetary orbiters and landers has made great advances since the signature Viking mission of the seventies. At some point, however, the science return from orbital remote sensing, and even in situ measurements, becomes incremental, rather than revolutionary. This is primarily caused by the low spatial resolution of such measurements, even for landed instrumentation, the incomplete mineralogical record derived from such measurements, the inability to do the detailed textural, mineralogical and compositional characterization needed to demonstrate equilibrium or reaction paths, and the lack of chronological characterization. For the foreseeable future, flight instruments will suffer from this limitation. In order to make the next revolutionary breakthrough in understanding the early geological and climatological history of Mars, samples must be available for interrogation using the full panoply of laboratory-housed analytical instrumentation. Laboratory studies of samples allow for determination of parageneses of rocks through microscopic identification of mineral assemblages, evaluation of equilibrium through electron microbeam analyses of mineral compositions and structures, determination of formation temperatures through secondary ion or thermal ionization mass spectrometry (SIMS or TIMS) analyses of stable isotope compositions. Such details are poorly constrained by orbital data (e.g. phyllosilicate formation at Mawrth Vallis), and incompletely described by in situ measurements (e.g. genesis of Burns formation sediments at Meridiani Planum). Laboratory studies can determine formation, metamorphism and/or alteration ages of samples through SIMS or TIMS of radiogenic isotope systems; a capability well-beyond flight instrumentation. Ideally, sample return should be from a location first scouted by landers such that fairly mature hypotheses have been formulated that can be tested. However, samples from clastic sediments derived from an extensive region of Mars can provide important, detailed understanding of early martian geological and climatological history. Interrogating clastic "sediments" from the Earth, Moon and asteroids has allowed discovery of new crustal units, identification of now-vanished crust, and determination of the geological history of extensive, remote regions. Returned sample of martian fluvial and/or aeolian sediments, for example from Gale crater, could be "read like a book" in terrestrial laboratories to provide truly revolutionary new insights into early martian geological and climatological evolution.

  7. A Multiplexed Diagnostic Platform for Point-of-Care Pathogen Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Regan, J F; Letant, S E; Adams, K L

    2008-02-04

    We developed an automated point-of-care diagnostic instrument that is capable of analyzing nasal swab samples for the presence of respiratory diseases. This robust instrument, called FluIDx, performs autonomous multiplexed RT-PCR reactions that are analyzed by microsphere xMAP technology. We evaluated the performance of FluIDx, in comparison rapid tests specific for influenza and respiratory syncytial virus, in a clinical study performed at the UC Davis Medical Center. The clinical study included samples positive for RSV (n = 71), influenza A (n = 16), influenza B (n = 4), adenovirus (n = 5), parainfluenza virus (n = 2), and 44 negative samples,more » according to a composite reference method. FluIDx and the rapid tests detected 85.9% and 62.0% of the RSV positive samples, respectively. Similar sensitivities were recorded for the influenza B samples; whereas the influenza A samples were poorly detected, likely due to the utilization of an influenza A signature that did not accurately match currently circulating influenza A strains. Data for all pathogens were compiled and indicate that FluIDx is more sensitive than the rapid tests, detecting 74.2% (95% C.I. of 64.7-81.9%) of the positive samples in comparison to 53.6% (95% C.I. of 43.7-63.2%) for the rapid tests. The higher sensitivity of FluIDx was partially offset by a lower specificity, 77.3% versus 100.0%. Overall, these data suggest automated flow-through PCR-based instruments that perform multiplexed assays can successfully screen clinical samples for infectious diseases.« less

  8. The cobas p 630 instrument: a dedicated pre-analytic solution to optimize COBAS® AmpliPrep/COBAS® TaqMan® system workflow and turn-around-time.

    PubMed

    Vallefuoco, L; Sorrentino, R; Spalletti Cernia, D; Colucci, G; Portella, G

    2012-12-01

    The cobas p 630, a fully automated pre-analytical instrument for primary tube handling recently introduced to complete the Cobas(®) TaqMan systems portfolio, was evaluated in conjunction with: the COBAS(®) AmpliPrep/COBAS(®) TaqMan HBV Test, v2.0, COBAS(®) AmpliPrep/COBAS(®) TaqMan HCV Test, v1.0 and COBAS(®) AmpliPrep/COBAS(®) TaqMan HIV Test, v2.0. The instrument performance in transferring samples from primary to secondary tubes, its impact in improving COBAS(®) AmpliPrep/COBAS(®) TaqMan workflow and hands-on reduction and the risk of possible cross-contamination were assessed. Samples from 42 HBsAg positive, 42 HCV and 42 HIV antibody (Ab) positive patients as well as 21 healthy blood donors were processed with or without automated primary tubes. HIV, HCV and HBsAg positive samples showed a correlation index of 0.999, 0.987 and of 0.994, respectively. To assess for cross-contamination, high titer HBV DNA positive samples, HCV RNA and HIV RNA positive samples were distributed in the cobas p 630 in alternate tube positions, adjacent to negative control samples within the same rack. None of the healthy donor samples showed any reactivity. Based on these results, the cobas p 630 can improve workflow and sample tracing in laboratories performing molecular tests, and reduce turnaround time, errors, and risks. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Instruments for Assessing Risk of Bias and Other Methodological Criteria of Published Animal Studies: A Systematic Review

    PubMed Central

    Krauth, David; Woodruff, Tracey J.

    2013-01-01

    Background: Results from animal toxicology studies are critical to evaluating the potential harm from exposure to environmental chemicals or the safety of drugs prior to human testing. However, there is significant debate about how to evaluate the methodology and potential biases of the animal studies. There is no agreed-upon approach, and a systematic evaluation of current best practices is lacking. Objective: We performed a systematic review to identify and evaluate instruments for assessing the risk of bias and/or other methodological criteria of animal studies. Method: We searched Medline (January 1966–November 2011) to identify all relevant articles. We extracted data on risk of bias criteria (e.g., randomization, blinding, allocation concealment) and other study design features included in each assessment instrument. Discussion: Thirty distinct instruments were identified, with the total number of assessed risk of bias, methodological, and/or reporting criteria ranging from 2 to 25. The most common criteria assessed were randomization (25/30, 83%), investigator blinding (23/30, 77%), and sample size calculation (18/30, 60%). In general, authors failed to empirically justify why these or other criteria were included. Nearly all (28/30, 93%) of the instruments have not been rigorously tested for validity or reliability. Conclusion: Our review highlights a number of risk of bias assessment criteria that have been empirically tested for animal research, including randomization, concealment of allocation, blinding, and accounting for all animals. In addition, there is a need for empirically testing additional methodological criteria and assessing the validity and reliability of a standard risk of bias assessment instrument. Citation: Krauth D, Woodruff TJ, Bero L. 2013. Instruments for assessing risk of bias and other methodological criteria of published animal studies: a systematic review. Environ Health Perspect 121:985–992 (2013); http://dx.doi.org/10.1289/ehp.1206389 PMID:23771496

  10. A behaviourally anchored rating scale for evaluating the use of the WHO surgical safety checklist: development and initial evaluation of the WHOBARS.

    PubMed

    Devcich, Daniel A; Weller, Jennifer; Mitchell, Simon J; McLaughlin, Scott; Barker, Lauren; Rudolph, Jenny W; Raemer, Daniel B; Zammert, Martin; Singer, Sara J; Torrie, Jane; Frampton, Chris Ma; Merry, Alan F

    2016-10-01

    Realising the full potential of the WHO Surgical Safety Checklist (SSC) to reduce perioperative harm requires the constructive engagement of all operating room (OR) team members during its administration. To facilitate research on SSC implementation, a valid and reliable instrument is needed for measuring OR team behaviours during its administration. We developed a behaviourally anchored rating scale (BARS) for this purpose. We used a modified Delphi process, involving 16 subject matter experts, to compile a BARS with behavioural domains applicable to all three phases of the SSC. We evaluated the instrument in 80 adult OR cases and 30 simulated cases using two medical student raters and seven expert raters, respectively. Intraclass correlation coefficients were calculated to assess inter-rater reliability. Internal consistency and instrument discrimination were explored. Sample size estimates for potential study designs using the instrument were calculated. The Delphi process resulted in a BARS instrument (the WHOBARS) with five behavioural domains. Intraclass correlation coefficients calculated from the OR cases exceeded 0.80 for 80% of the instrument's domains across the SSC phases. The WHOBARS showed high internal consistency across the three phases of the SSC and ability to discriminate among surgical cases in both clinical and simulated settings. Fewer than 20 cases per group would be required to show a difference of 1 point between groups in studies of the SSC, where α=0.05 and β=0.8. We have developed a generic instrument for comprehensively rating the administration of the SSC and informing initiatives to realise its full potential. We have provided data supporting its capacity for discrimination, internal consistency and inter-rater reliability. Further psychometric evaluation is warranted. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  11. The Instrument for Measuring the Implementation Situation of Traditional Chinese Medicine Guideline: Evaluation and Application

    PubMed Central

    Wang, Yangyang; Chen, Yaolong; Wang, Xiaoyun; Deng, Jingwen

    2017-01-01

    Clinical practice guidelines play an important role in reducing the variations in clinical practices and improving the quality of care. To assess the real effect, measuring its implementation situation is needed. The implementation situation can be reflected by testing the consistency between the actual clinical practice and the guideline. We constructed an instrument to measure the implementation situation of Traditional Chinese Medicine (TCM) guideline through consistency testing. The main objectives of our study were to validate the instrument and evaluate the implementation situation of menopause syndrome guideline of TCM, using the data from the consistency test of comparing the medical records with the guideline. A total of 621 cases were included for data analysis. Cronbach's Alpha coefficient is 0.73. The model fit of 7 items in four dimensions was good (SRMR = 0.04; GFI = 0.97; NFI = 0.97; TLI = 0.96; CFI = 0.98; AGFI = 0.90). This instrument is of good reliability and validity. It can help the guideline developers to measure the implementation situation, find the reasons affecting the implementation, and revise the guideline. The method of using consistency test to measure the implementation situation may provide a sample for evaluating the guideline implementation in other fields. PMID:29234379

  12. Measurement properties of instruments that assess participation in young people with autism spectrum disorder: a systematic review.

    PubMed

    Lami, Francesca; Egberts, Kristine; Ure, Alexandra; Conroy, Rowena; Williams, Katrina

    2018-03-01

    To systematically review the measurement properties of instruments assessing participation in young people with autism spectrum disorder (ASD). A search was performed in MEDLINE, PsycINFO, and PubMed combining three constructs ('ASD', 'test of participation', 'measurement properties'). Results were restricted to articles including people aged 6 to 29 years. The 2539 identified articles were independently screened by two reviewers. For the included articles, data were extracted using standard forms and their risk of bias was assessed. Nine studies (8 cross-sectional) met the inclusion criteria, providing information on seven different instruments. The total sample included 634 participants, with sex available for 600 (males=494; females=106) and age available for 570, with mean age for these participants 140.58 months (SD=9.11; range=36-624). Included instruments were the school function assessment, vocational index, children's assessment of participation and enjoyment/preferences for activities of children, experience sampling method, Pediatric Evaluation of Disability Inventory, Computer Adaptive Test, adolescent and young adult activity card sort, and Patient-Reported Outcomes Measurement Information System parent-proxy peer relationships. Seven studies assessed reliability and validity; good properties were reported for half of the instruments considered. Most studies (n=6) had high risk of bias. Overall the quality of the evidence for each tool was limited. Validation of these instruments, or others that comprehensively assess participation, is needed. Future studies should follow recommended methodological standards. Seven instruments have been used to assess participation in young people with autism. One instrument, with excellent measurement properties in one study, does not comprehensively assess participation. Studies of three instruments that incorporate a more comprehensive assessment of participation have methodological limitations. Overall, limited evidence exists regarding measurement properties of participation assessments for young people with autism. © 2017 Mac Keith Press.

  13. Psychometric Properties of the "Miranda Rights Comprehension Instruments" with a Juvenile Justice Sample

    ERIC Educational Resources Information Center

    Goldstein, Naomi E. Sevin; Romaine, Christina L. Riggs; Zelle, Heather; Kalbeitzer, Rachel; Mesiarik, Constance; Wolbransky, Melinda

    2011-01-01

    This article describes the psychometric properties of the "Miranda Rights Comprehension Instruments", the revised version of Grisso's "Miranda" instruments. The original instruments demonstrated good reliability and validity in a normative sample. The revised instruments updated the content of the original instruments and were…

  14. Comparison of the analytical capabilities of the BAC Datamaster and Datamaster DMT forensic breath testing devices.

    PubMed

    Glinn, Michele; Adatsi, Felix; Curtis, Perry

    2011-11-01

    The State of Michigan uses the Datamaster as an evidential breath testing device. The newest version, the DMT, will replace current instruments in the field as they are retired from service. The Michigan State Police conducted comparison studies to test the analytical properties of the new instrument and to evaluate its response to conditions commonly cited in court defenses. The effects of mouth alcohol, objects in the mouth, and radiofrequency interference on paired samples from drinking subjects were assessed on the DMT. The effects of sample duration and chemical interferents were assessed on both instruments, using drinking subjects and wet-bath simulators, respectively. Our testing shows that Datamaster and DMT results are essentially identical; the DMT gave accurate readings as compared with measurements made using simulators containing standard ethanol solutions and that the DMT did not give falsely elevated breath alcohol results from any of the influences tested. © 2011 American Academy of Forensic Sciences.

  15. Atmospheric Electron-Induced X-Ray Spectrometer (AEXS) Development

    NASA Technical Reports Server (NTRS)

    Wilcox, Jaroslava Z.; Urgiles, Eduardo; Toda, Risaku; George, Thomas; Douglas, Susanne; Crisp, Joy

    2005-01-01

    This paper describes the progress in the development of the so-called Atmospheric Electron X-ray Spectrometer (AEXS) instrument in our laboratory at JPL. The AEXS is a novel miniature instrument concept based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam, for non-destructive evaluation of surfaces of samples in situ, in planetary ambient atmosphere. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum within the AEXS electron source from the outside ambient atmosphere. By using a focused electron beam, the impinging electrons on samples in the external atmosphere excite XRF spectra from the irradiated spots with high-to-medium spatial resolution. The XRF spectra are analyzed using an energy-dispersive detector to determine surface elemental composition. The use of high- intensity electron beam results in rapid spectrum acquisition (several minutes), and consequently low energy consumption (several tens of Joules) per acquired XRF spectrum in comparison to similar portable instruments.

  16. Research Measures for Dyscalculia: A Validity and Reliability Study.

    ERIC Educational Resources Information Center

    Geiman, R. M.

    1986-01-01

    This study sought to evaluate a measure of dyscalculia to determine its validity and reliability. It also tested use of the instrument with seventh graders and ascertained where errors attributed to dyscalculia were also present in an average sample of seventh graders. Results varied. (MNS)

  17. Instructor Touch Enhanced College Students' Evaluations

    ERIC Educational Resources Information Center

    Legg, Angela M.; Wilson, Janie H.

    2013-01-01

    Touch between people is associated with several outcomes, including reduced stress, more positive mood, enhanced feelings of closeness, and positive behavioral change. However, the potential utility of touch rarely has been examined in a college sample, with teachers touching their students. In the present study, we used instrumental touch…

  18. EMR Behavioral Curriculum and Student Record.

    ERIC Educational Resources Information Center

    Hartnett, John J.

    Intended for use as a curriculum guide, a source for objectives for the individualized educational plan, and an evaluation instrument to measure handicapped students' learning, the guide lists sequences of developmental tasks. Tasks are outlined for primary, intermediate, and secondary levels in the following areas (sample subskills in…

  19. Evaluation of the sounding rod method for sampling coarse riverbed sediments in non-wadeable streams and rivers

    EPA Science Inventory

    The substrate of fluvial systems is regularly characterized as part of a larger physical habitat assessment. Beyond contributing to a basic scientific understanding of fluvial systems, these measures are instrumental in meeting the regulatory responsibilities of bioassessment and...

  20. Evaluation of the Air Quality Monitor's Performance on the International Space Station

    NASA Technical Reports Server (NTRS)

    Limero, Thomas; Reese, Eric; Ballard, Ken; Durham, Tamara

    2010-01-01

    The Air Quality Monitor (AQM) was flown to the International Space Station (ISS) as an experiment to evaluate its potential to replace the aging Volatile Organic Analyzer (VOA), which ceased operations in August 2009. The AQM (Figure 1) is a small gas chromatography/differential mobility spectrometer (GC/DMS) manufactured by Sionex. Data was presented at last year s ISIMS conference that detailed the preparation of the AQM for flight, including instrument calibration. Furthermore, initial AQM data was compared to VOA results from simultaneous runs of the two instruments. Although comparison with VOA data provided a measure of confidence in the AQM performance, it is the comparison with results from simultaneously acquired air samples (grab sample containers-GSCs) that will define the success (or failure) of the AQM performance. This paper will update the progress in the AQM investigation by comparing AQM data to results from the analyses of GSC samples, returned from ISS. Additionally, a couple of example will illustrate the AQM s ability to detect disruptions in the spacecraft s air quality. Discussion will also focus upon a few unexpected issues that have arisen and how these will be a addressed in the final operational unit now being built.

  1. The long-term effects of war experiences on children's depression in the Republic of Croatia.

    PubMed

    Brajsa-Zganec, Andreja

    2005-01-01

    The aim of the study was to investigate whether different levels of depressive symptoms in early adolescent boys and girls could be predicted on the basis of war experiences, perceived available social support (instrumental support, support to self-esteem, belonging and acceptance) and extraversion. The sample consisted of 583 children ages 12 to 15 years; 283 children were displaced from different parts of Croatia for a period of approximately three and a half years. The following instruments were administered: Questionnaire on Children's Stressful and Traumatic War Experiences, Reynolds Adolescent Depression Scale, Junior Eysenck Personality Questionnaire, and Interpersonal Support Evaluation List. Regression analyses showed that more war experiences were related to more depressive symptoms for boys only. The greater extent of perceived available social support for boys (instrumental support, support to self-esteem, belonging and acceptance) related to fewer depressive symptoms. For girls, perceived instrumental support and self-esteem were related to fewer depressive symptoms. Predictors in the boys' sample accounted for 35% of the variance in the results on the depression scale, and 27% in the girls' sample. We conclude that boys suffer more from the long-term effects of war than girls. In situations where children cannot be shielded from stressful events, such as war, a greater level of perceived social support is related to fewer depressive symptoms both for boys and girls in early adolescence.

  2. Schematic of Sample Analysis at Mars SAM Instrument

    NASA Image and Video Library

    2011-01-18

    This schematic illustration for NASA Mars Science Laboratory Sample Analysis at Mars SAM instrument shows major components of the microwave-oven-size instrument, which will examine samples of Martian rocks, soil and atmosphere.

  3. A preliminary psychometric evaluation of the eight-item cognitive load scale.

    PubMed

    Pignatiello, Grant A; Tsivitse, Emily; Hickman, Ronald L

    2018-04-01

    The aim of this article is to report the psychometric properties of the eight-item cognitive load scale. According to cognitive load theory, the formatting and delivery of healthcare education influences the degree to which patients and/or family members can engage their working memory systems for learning. However, despite its relevance, cognitive load has not yet been evaluated among surrogate decision makers exposed to electronic decision support for healthcare decisions. To date, no psychometric analyses of instruments evaluating cognitive load have been reported within healthcare settings. A convenience sample of 62 surrogate decision makers for critically ill patients were exposed to one of two healthcare decision support interventions were recruited from four intensive care units at a tertiary medical center in Northeast Ohio. Participants were administered a battery of psychosocial instruments and the eight-item cognitive load scale (CLS). The CLS demonstrated a bidimensional factor structure with acceptable discriminant validity and internal consistency reliability (Cronbach's α = 0.75 and 0.89). The CLS is a psychometrically sound instrument that may be used in the evaluation of decision support among surrogate decision makers of the critically ill. The authors recommend application of the cognitive load scale in the evaluation and development of healthcare education and interventions. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. The Chinese version of the Pediatric Quality of Life Inventory™ (PedsQL™) Family Impact Module: cross-cultural adaptation and psychometric evaluation.

    PubMed

    Chen, Ruoqing; Hao, Yuantao; Feng, Lifen; Zhang, Yingfen; Huang, Zhuoyan

    2011-03-23

    A pediatric chronic health condition not only influences a child's life, but also has impacts on parent health-related quality of life (HRQOL) and family functioning. To provide care and social support to these families, a psychometrically well-developed instrument for measuring these impacts is of great importance. The present study is aimed to evaluate the psychometric properties of the Chinese version of the PedsQL™ Family Impact Module. The cross-cultural adaptation of the PedsQL™ Family Impact Module was performed following the PedsQL™ Measurement Model Translation Methodology. The Chinese version of the PedsQL™ Family Impact Module was administered to 136 parents of children with asthma and 264 parents of children with heart disease from four Triple A hospitals. The psychometric properties such as feasibility, internal consistency reliability, item-subscale correlations and construct validity were evaluated. The percentage of missing item responses was less than 0.1% for both asthma and heart disease sample groups. The Chinese version of the PedsQL™ Family Impact Module showed ceiling effects but had acceptable reliability (Cronbach's Alpha Coefficients were higher than 0.7 in all the subscales except "Daily Activities" in the asthma sample group). There were higher correlation coefficients between items and their hypothesized subscales than those with other subscales. The asthma sample group reported higher parent HRQOL and family functioning than the heart disease sample group. In the heart disease sample group, parents of outpatients reported higher parent HRQOL and family functioning than parents of inpatients. Confirmatory factor analysis showed that the instrument had marginally acceptable construct validity with some Goodness-of-Fit indices not reaching the standard indicating acceptable model fit. The Chinese version of the PedsQL™ Family Impact Module has adequate psychometric properties and could be used to assess the impacts of pediatric asthma or pediatric heart disease on parent HRQOL and family functioning in China. This instrument should be field tested on parents of children with other chronic medical conditions in other areas. Construct validity tested by confirmatory factor analysis and test-retest reliability should be further assessed.

  5. Cutting efficiency of four different rotary nickel: Titanium instruments

    PubMed Central

    Cecchin, Doglas; de Sousa-Neto, Manoel Damião; Pécora, Jesus Djalma; Gariba-Silva, Ricardo

    2011-01-01

    Aim: The aim of this study was to evaluate the cutting efficiency of rotary nickel-titanium (NiTi) instruments K3, NiTi Tee, Profile, and Quantec with taper size 04/25. Materials and Methods: The number of samples was 10 for each group (n = 10). The cutting efficiency was measured by the mass loss from each acrylic resin block after instrumentation of a simulated canal using the Crown-down technique. Results: The analysis of variance (ANOVA) showed that there was a statistically significant difference among the studied groups. The Tukey's test showed that the acrylic resin blocks prepared with instruments K3 (0.00369 ± 0.00022), NiTi Tee (0.00368 ± 0.00023), and Profile (0.00351 ± 0.00026) presented the greatest mass loss, showing no statistically significant difference among them (P < 0.05). The lowest mass loss was found in the blocks prepared with Quantec instruments (0.00311 ± 0.0003) (P < 0.05). Conclusions: It could be concluded that the K3, NiTi Tee, and Profile instruments presented a greater cutting efficiency than the Quantec instruments. PMID:21814349

  6. [Development of a questionnaire to measure family stress among married working women].

    PubMed

    Kim, Gwang Suk; Cho, Won Jung

    2006-08-01

    Even though a number of studies have suggested that appropriate measuring instruments of family stress for working women have to be developed, the validity and reliability of the instruments used have not been consistently examined. The purpose of the present study was to develop a sensitive instrument to measure family stress for married working women, and to test the validity and reliability of the instrument. The items generated for this instrument were drawn from a comprehensive literature review. Twenty four items were developed through evaluation by 10 experts and twenty one items were finally confirmed through item analysis. Psychometric testing was preformed and confirmed with a convenient sample of 240 women employed in the industrial sector. Four factors evolved by factor analysis, which explained 50.5% of the total variance. The first factor 'Cooperation' explained 28.1%, 2nd factor 'Satisfaction with relationships' 10.6%, 3rd factor 'Democratic and comfortable environment' 6.3%, and 4th factor 'Disturbance of own living' 5.5%. Cronbach's coefficient of this instrument was 0.86. The study supports the validity and reliability of the instrument.

  7. Evaluation of the performance of microprocessor-based colorimeter

    PubMed Central

    Randhawa, S. S.; Gupta, R. C.; Bhandari, A. K.; Malhotra, P. S.

    1992-01-01

    Colorimetric estimations have an important role in quantitative studies. An inexpensive and portable microprocessor-based colorimeter developed by the authors is described in this paper. The colorimeter uses a light emitting diode as the light source; a pinphotodiode as the detector and an 8085A microprocessor. Blood urea, glucose, total protein, albumin and bilirubin from patient blood samples were analysed with the instrument and results obtained were compared with assays of the same blood using a Spectronic 21. A good correlation was found between the results from the two instruments. PMID:18924952

  8. Evaluation of the performance of microprocessor-based colorimeter.

    PubMed

    Randhawa, S S; Gupta, R C; Bhandari, A K; Malhotra, P S

    1992-01-01

    Colorimetric estimations have an important role in quantitative studies. An inexpensive and portable microprocessor-based colorimeter developed by the authors is described in this paper. The colorimeter uses a light emitting diode as the light source; a pinphotodiode as the detector and an 8085A microprocessor. Blood urea, glucose, total protein, albumin and bilirubin from patient blood samples were analysed with the instrument and results obtained were compared with assays of the same blood using a Spectronic 21. A good correlation was found between the results from the two instruments.

  9. Capillary electrophoresis-MALDI interface based on inkjet technology

    PubMed Central

    Vannatta, Michael W.; Whitmore, Colin D.; Dovichi, Norman J.

    2010-01-01

    An ink jet printer valve and nozzle were used to deliver matrix and sample from an electrophoresis capillary onto a MALDI plate. The system was evaluated by separation of a set of standard peptides. That separation generated up to 40,000 theoretical plates in less than three minutes. Detection limits were 500 amol using an ABI TOF-TOF instrument and 2 fmol for an ABI Q-TOF instrument. Over 70% coverage was obtained for the tryptic digest of α-lactalbumin in less than 2.5 minutes. PMID:19960472

  10. [Evaluation of digital educational student-technology interaction in neonatal nursing].

    PubMed

    Castro, Fernanda Salim Ferreira de; Dias, Danielle Monteiro Vilela; Higarashi, Ieda Harumi; Scochi, Carmen Gracinda Silvan; Fonseca, Luciana Mara Monti

    2015-02-01

    To assess the digital educational technology interface Caring for the sensory environment in the neonatal unit: noise, lighting and handling based on ergonomic criteria. Descriptive study, in which we used the guidelines and ergonomic criteria established by ISO 9241-11 and an online Likert scale instrument to identify problems and interface qualities. The instrument was built based on Ergolist, which follows the criteria of ISO 9141-11. There were 58 undergraduate study participants from the School of Nursing of Ribeirao Preto, University of Sao Paulo, who attended the classes about neonatal nursing content. All items were positively evaluated by more than 70% of the sample. Educational technology is appropriate according to the ergonomic criteria and can be made available for teaching nursing students.

  11. An evaluation of a new instrument to measure organisational safety culture values and practices.

    PubMed

    Díaz-Cabrera, D; Hernández-Fernaud, E; Isla-Díaz, R

    2007-11-01

    The main aim of this research is to evaluate a safety culture measuring instrument centred upon relevant organisational values and practices related to the safety management system. Seven dimensions that reflect underlying safety meanings are proposed. A second objective is to explore the four cultural orientations in the field of safety arising from the competing values framework. The study sample consisted of 299 participants from five companies in different sectors. The results show six dimensions of organisational values and practices and different company profiles in the organisations studied. The four cultural orientations proposed by the competing values framework are not confirmed. Nevertheless, a coexistence of diverse cultural orientations or paradoxes in the companies is observed.

  12. The development and psychometric properties of the American sign language proficiency assessment (ASL-PA).

    PubMed

    Maller, S; Singleton, J; Supalla, S; Wix, T

    1999-01-01

    We describe the procedures for constructing an instrument designed to evaluate children's proficiency in American Sign Language (ASL). The American Sign Language Proficiency Assessment (ASL-PA) is a much-needed tool that potentially could be used by researchers, language specialists, and qualified school personnel. A half-hour ASL sample is collected on video from a target child (between ages 6 and 12) across three separate discourse settings and is later analyzed and scored by an assessor who is highly proficient in ASL. After the child's language sample is scored, he or she can be assigned an ASL proficiency rating of Level 1, 2, or 3. At this phase in its development, substantial evidence of reliability and validity has been obtained for the ASL-PA using a sample of 80 profoundly deaf children (ages 6-12) of varying ASL skill levels. The article first explains the item development and administration of the ASL-PA instrument, then describes the empirical item analysis, standard setting procedures, and evidence of reliability and validity. The ASL-PA is a promising instrument for assessing elementary school-age children's ASL proficiency. Plans for further development are also discussed.

  13. Evaluating Instrument Quality in Science Education: Rasch-based analyses of a Nature of Science test

    NASA Astrophysics Data System (ADS)

    Neumann, Irene; Neumann, Knut; Nehm, Ross

    2011-07-01

    Given the central importance of the Nature of Science (NOS) and Scientific Inquiry (SI) in national and international science standards and science learning, empirical support for the theoretical delineation of these constructs is of considerable significance. Furthermore, tests of the effects of varying magnitudes of NOS knowledge on domain-specific science understanding and belief require the application of instruments validated in accordance with AERA, APA, and NCME assessment standards. Our study explores three interrelated aspects of a recently developed NOS instrument: (1) validity and reliability; (2) instrument dimensionality; and (3) item scales, properties, and qualities within the context of Classical Test Theory and Item Response Theory (Rasch modeling). A construct analysis revealed that the instrument did not match published operationalizations of NOS concepts. Rasch analysis of the original instrument-as well as a reduced item set-indicated that a two-dimensional Rasch model fit significantly better than a one-dimensional model in both cases. Thus, our study revealed that NOS and SI are supported as two separate dimensions, corroborating theoretical distinctions in the literature. To identify items with unacceptable fit values, item quality analyses were used. A Wright Map revealed that few items sufficiently distinguished high performers in the sample and excessive numbers of items were present at the low end of the performance scale. Overall, our study outlines an approach for how Rasch modeling may be used to evaluate and improve Likert-type instruments in science education.

  14. Evaluating Written Patient Information for Eczema in German: Comparing the Reliability of Two Instruments, DISCERN and EQIP

    PubMed Central

    McCool, Megan E.; Wahl, Josepha; Schlecht, Inga; Apfelbacher, Christian

    2015-01-01

    Patients actively seek information about how to cope with their health problems, but the quality of the information available varies. A number of instruments have been developed to assess the quality of patient information, primarily though in English. Little is known about the reliability of these instruments when applied to patient information in German. The objective of our study was to investigate and compare the reliability of two validated instruments, DISCERN and EQIP, in order to determine which of these instruments is better suited for a further study pertaining to the quality of information available to German patients with eczema. Two independent raters evaluated a random sample of 20 informational brochures in German. All the brochures addressed eczema as a disorder and/or therapy options and care. Intra-rater and inter-rater reliability were assessed by calculating intra-class correlation coefficients, agreement was tested with weighted kappas, and the correlation of the raters’ scores for each instrument was measured with Pearson’s correlation coefficient. DISCERN demonstrated substantial intra- and inter-rater reliability. It also showed slightly better agreement than EQIP. There was a strong correlation of the raters’ scores for both instruments. The findings of this study support the reliability of both DISCERN and EQIP. However, based on the results of the inter-rater reliability, agreement and correlation analyses, we consider DISCERN to be the more precise tool for our project on patient information concerning the treatment and care of eczema. PMID:26440612

  15. Evaluating Written Patient Information for Eczema in German: Comparing the Reliability of Two Instruments, DISCERN and EQIP.

    PubMed

    McCool, Megan E; Wahl, Josepha; Schlecht, Inga; Apfelbacher, Christian

    2015-01-01

    Patients actively seek information about how to cope with their health problems, but the quality of the information available varies. A number of instruments have been developed to assess the quality of patient information, primarily though in English. Little is known about the reliability of these instruments when applied to patient information in German. The objective of our study was to investigate and compare the reliability of two validated instruments, DISCERN and EQIP, in order to determine which of these instruments is better suited for a further study pertaining to the quality of information available to German patients with eczema. Two independent raters evaluated a random sample of 20 informational brochures in German. All the brochures addressed eczema as a disorder and/or therapy options and care. Intra-rater and inter-rater reliability were assessed by calculating intra-class correlation coefficients, agreement was tested with weighted kappas, and the correlation of the raters' scores for each instrument was measured with Pearson's correlation coefficient. DISCERN demonstrated substantial intra- and inter-rater reliability. It also showed slightly better agreement than EQIP. There was a strong correlation of the raters' scores for both instruments. The findings of this study support the reliability of both DISCERN and EQIP. However, based on the results of the inter-rater reliability, agreement and correlation analyses, we consider DISCERN to be the more precise tool for our project on patient information concerning the treatment and care of eczema.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Madden, Jeremy T.; Toth, Scott J.; Dettmar, Christopher M.

    Nonlinear optical (NLO) instrumentation has been integrated with synchrotron X-ray diffraction (XRD) for combined single-platform analysis, initially targeting applications for automated crystal centering. Second-harmonic-generation microscopy and two-photon-excited ultraviolet fluorescence microscopy were evaluated for crystal detection and assessed by X-ray raster scanning. Two optical designs were constructed and characterized; one positioned downstream of the sample and one integrated into the upstream optical path of the diffractometer. Both instruments enabled protein crystal identification with integration times between 80 and 150 µs per pixel, representing a ~10 3–10 4-fold reduction in the per-pixel exposure time relative to X-ray raster scanning. Quantitative centering andmore » analysis of phenylalanine hydroxylase fromChromobacterium violaceumcPAH,Trichinella spiralisdeubiquitinating enzyme TsUCH37, human κ-opioid receptor complex kOR-T4L produced in lipidic cubic phase (LCP), intimin prepared in LCP, and α-cellulose samples were performed by collecting multiple NLO images. The crystalline samples were characterized by single-crystal diffraction patterns, while α-cellulose was characterized by fiber diffraction. Good agreement was observed between the sample positions identified by NLO and XRD raster measurements for all samples studied.« less

  17. Developing instruments concerning scientific epistemic beliefs and goal orientations in learning science: a validation study

    NASA Astrophysics Data System (ADS)

    Lin, Tzung-Jin; Tsai, Chin-Chung

    2017-11-01

    The purpose of this study was to develop and validate two survey instruments to evaluate high school students' scientific epistemic beliefs and goal orientations in learning science. The initial relationships between the sampled students' scientific epistemic beliefs and goal orientations in learning science were also investigated. A final valid sample of 600 volunteer Taiwanese high school students participated in this survey by responding to the Scientific Epistemic Beliefs Instrument (SEBI) and the Goal Orientations in Learning Science Instrument (GOLSI). Through both exploratory and confirmatory factor analyses, the SEBI and GOLSI were proven to be valid and reliable for assessing the participants' scientific epistemic beliefs and goal orientations in learning science. The path analysis results indicated that, by and large, the students with more sophisticated epistemic beliefs in various dimensions such as Development of Knowledge, Justification for Knowing, and Purpose of Knowing tended to adopt both Mastery-approach and Mastery-avoidance goals. Some interesting results were also found. For example, the students tended to set a learning goal to outperform others or merely demonstrate competence (Performance-approach) if they had more informed epistemic beliefs in the dimensions of Multiplicity of Knowledge, Uncertainty of Knowledge, and Purpose of Knowing.

  18. Advancements in the safe identification of explosives using a Raman handheld instrument (ACE-ID)

    NASA Astrophysics Data System (ADS)

    Arnó, Josep; Frunzi, Michael; Kittredge, Marina; Sparano, Brian

    2014-05-01

    Raman spectroscopy is the technology of choice to identify bulk solid and liquid phase unknown samples without the need to contact the substance. Materials can be identified through transparent and semi-translucent containers such as plastic and glass. ConOps in emergency response and military field applications require the redesign of conventional laboratory units for: field portability; shock, thermal and chemical attack resistance; easy and intuitive use in restrictive gear; reduced size, weight, and power. This article introduces a new handheld instrument (ACE-IDTM) designed to take Raman technology to the next level in terms of size, safety, speed, and analytical performance. ACE-ID is ruggedized for use in severe climates and terrains. It is lightweight and can be operated with just one hand. An intuitive software interface guides users through the entire identification process, making it easy-to-use by personnel of different skill levels including military explosive ordinance disposal technicians, civilian bomb squads and hazmat teams. Through the use of embedded advanced algorithms, the instrument is capable of providing fluorescence correction and analysis of binary mixtures. Instrument calibration is performed automatically upon startup without requiring user intervention. ACE-ID incorporates an optical rastering system that diffuses the laser energy over the sample. This important innovation significantly reduces the heat induced in dark samples and the probability of ignition of susceptible explosive materials. In this article, the explosives identification performance of the instrument will be provided in addition to a quantitative evaluation of the safety improvements derived from the reduced ignition probabilities.

  19. RLS Instrument Radiometric Model: Instrument performance theoretical evaluation and experimental checks

    NASA Astrophysics Data System (ADS)

    Quintana, César; Ramos, Gonzalo; Moral, Andoni; Rodriguez, Jose Antonio; Pérez, Carlos; Hutchinson, Ian; INGLEY, Richard; Rull, Fernando

    2016-10-01

    Raman Laser Spectrometer (RLS) is one of the Pasteur payload instruments located at the Rover of the ExoMars mission and within the ESA's Aurora Exploration Programme. RLS will explore the Mars surface composition through the Raman spectroscopy technique. The instrument is divided into several units: a laser for Raman emission stimulation, an internal optical head (iOH) for sample excitation and for Raman emission recovering, a spectrometer with a CCD located at its output (SPU), the optical harness (OH) for the units connection, from the laser to the excitation path of the iOH and from the iOH reception path to the spectrometer, and the corresponding electronics for the CCD operation.Due to the variability of the samples to be analyzed on Mars, a radiometry prediction for the instrument performance results to be of the critical importance. In such a framework, and taking into account the SNR (signal to noise ratio) required for the achievement of successful results from the scientific point of view (a proper information about the Mars surface composition), a radiometric model has been developed to provide the requirements for the different units, i.e. the laser irradiance, the iOH, OH, and SPU throughputs, and the samples that will be possible to be analyzed in terms of its Raman emission and the relationship of the Raman signal with respect to fluorescence emission, among others.The radiometric model fundamentals (calculations and approximations), as well as the first results obtained during the bread board characterization campaign are here reported on.

  20. A comparison of the EQ-5D-3L and ICECAP-O in an older post-acute patient population relative to the general population.

    PubMed

    Couzner, Leah; Crotty, Maria; Norman, Richard; Ratcliffe, Julie

    2013-08-01

    The measurement and valuation of quality of life forms a major component of economic evaluation in health care and is a major issue in health services research. However, differing approaches exist in the measurement and valuation of quality of life from a health economics perspective. While some instruments such as the EQ-5D-3L focus on health-related quality of life alone, others assess quality of life in broader terms, for example, the newly developed ICECAP-O. The aim of this study was to utilize two generic preference-based instruments, the EQ-5D-3L and the ICECAP-O, to measure and value the quality of life of older adult patients receiving post-acute care. An additional objective was to compare the values obtained by each instrument with those generated from two community-based general population samples. Data were collected from a clinical patient population of older adults receiving post-acute outpatient rehabilitation or residential transition care and two Australian general population samples of individuals residing in the general community. The individual responses to the ICECAP-O and EQ-5D-3L instruments were scored using recently developed Australian general population algorithms. Empirical comparisons were made of the resulting patient and general population sample values for the total population and dis-aggregated according to age (65-79 and 80+ years) and gender. A total of 1,260 participants aged 65-99 years (n = 86 clinical patient sample, n = 385 EQ-5D-3L general population sample, n = 789 ICECAP-O general population sample) completed one or both of the EQ-5D-3L and ICECAP-O instruments. As expected, the patient group demonstrated lower quality of life than the general population sample as measured by both quality-of-life instruments. The difference in values between the patient and general population groups was found to be far more pronounced for the EQ-5D-3L than for the ICECAP-O. The ICECAP-O was associated with a mean difference in values of 0.04 (patient group mean 0.753, SD 0.18; general population group mean 0.795, SD 0.17, respectively, p = 0.033). In contrast, the EQ-5D-3L was associated with a mean difference in values of 0.19 (patient group mean 0.595, SD 0.20; general population group mean 0.789, SD 0.02, respectively, p ≤ 0.001). The study findings illustrate the magnitude of the difference in patient and general population values according to the instrument utilized, and highlight the differences in both the theoretical underpinnings and valuation algorithms for the EQ-5D-3L and ICECAP-O instruments. Further empirical work is required in larger samples and alternative patient groups to investigate the generalizability of the findings presented here.

  1. CW Detection Instrument R&D Design Evaluation

    DTIC Science & Technology

    1993-11-01

    are known to be stable under a wide variety of sampling conditions. Our experiments showed, for example, that triethyl phosphite samples prepared in ... phosphite and triethyl phosphite , compounds number 8 and 9 in Schedule 3 in Table 2-1, respectively, is shown in Figure 3-18 for an injection...furnace which heats the column effluent to nearly 2000*C in the presence of hydrogen or air to convert halogenated organiks to hydro- 114 chioric acid

  2. Cross-cultural validation and psychometric evaluation of the Spanish Brief Religious Coping Scale (S-BRCS).

    PubMed

    Martinez, Nelda C; Sousa, Valmi D

    2011-07-01

    To evaluate the psychometric properties of the Spanish Brief Religious Coping Scale (S-BRCS). A descriptive correlational design was used to conduct the study among a convenience sample of 121 Mexican Americans with diabetes. The positive and negative religious coping subscales had Cronbach’s alphas of .85 and .86, respectively. All interitem and item-to-total correlations for each subscale were above the recommended criteria of .30. Factor loadings of the positive subscale using oblique (oblimin) and orthogonal (varimax) rotation ranged from .71 to .86 and from .72 to .86, respectively.Factor loadings of the negative subscale using oblimin and varimax rotation ranged from .64 to .83 and from .63 to .83,respectively. The S-BRCS was found to be a valid and reliable instrument to measure religious coping among Spanish-speaking Mexican Americans with type 2 diabetes. IMPLICATIONS FOR FURTHER RESEARCH AND PRACTICE: Further psychometric evaluation of the S-BRCS among larger sample of Mexican Americans and other Hispanic ethnic groups is warranted. The S-BRCS has the potential to become a standard instrument that can be used by clinicians who work with Hispanic clients with diabetes mellitus to provide culturally competent diabetes care.

  3. The Coopersmith Self-Esteem Inventory in an Adult Sample.

    ERIC Educational Resources Information Center

    Noller, Patricia; Shugm, David

    1988-01-01

    The reliability and validity of the Self-Esteem Inventory developed by S. C. Coopersmith (1975) were evaluated via item-total correlation, discriminant analysis, factor analysis, and analysis of variance of data for 352 Australian adults. The instrument had high internal consistency and discriminated well between subjects with high and low…

  4. Evaluation of Innovative Schools: OCDQ Results for Fifth-Year Teachers, 1970-1971.

    ERIC Educational Resources Information Center

    Broward County School Board, Fort Lauderdale, FL.

    A random sample is reported of fifth-year teachers from conventional schools and from open or innovative schools who completed the Organizational Climate Descriptions Questionnaire (OCDQ), administered anonymously, which measured subjective rather than objective dimensions. The instrument is interpreted as being primarily a measure of teacher…

  5. Perceptions of the Performance of Community College Faculty: Dissertation Research Findings.

    ERIC Educational Resources Information Center

    Vickers, Mozelle Carver

    A sample of 30 instructors nominated as effective teachers to the Piper Foundation and 31 randomly selected control instructors from the same 14 Texas colleges were evaluated by students, former students, administrators, peers, and the instructors themselves. The research instrument incorporated ten sets of characteristics expressed as polar…

  6. Measuring Economic Attitudes in High School.

    ERIC Educational Resources Information Center

    Walstad, William B.; Soper, John C.

    1983-01-01

    The instrument,"Survey on Economic Attitudes", developed to assess attitudes toward economics as a subject and attitudes toward economic issues, should find many uses in research or evaluation studies. Data on reliability, validity, and norms obtained from a national sample of high school students and college professors are discussed.…

  7. A Compact Optical Instrument with Artificial Neural Network for pH Determination

    PubMed Central

    Capel-Cuevas, Sonia; López-Ruiz, Nuria; Martinez-Olmos, Antonio; Cuéllar, Manuel P.; Pegalajar, Maria del Carmen; Palma, Alberto José; de Orbe-Payá, Ignacio; Capitán-Vallvey, Luis Fermin

    2012-01-01

    The aim of this work was the determination of pH with a sensor array-based optical portable instrument. This sensor array consists of eleven membranes with selective colour changes at different pH intervals. The method for the pH calculation is based on the implementation of artificial neural networks that use the responses of the membranes to generate a final pH value. A multi-objective algorithm was used to select the minimum number of sensing elements required to achieve an accurate pH determination from the neural network, and also to minimise the network size. This helps to minimise instrument and array development costs and save on microprocessor energy consumption. A set of artificial neural networks that fulfils these requirements is proposed using different combinations of the membranes in the sensor array, and is evaluated in terms of accuracy and reliability. In the end, the network including the response of the eleven membranes in the sensor was selected for validation in the instrument prototype because of its high accuracy. The performance of the instrument was evaluated by measuring the pH of a large set of real samples, showing that high precision can be obtained in the full range. PMID:22778668

  8. The Electric Field and Waves Instruments on the Radiation Belt Storm Probes Mission

    NASA Astrophysics Data System (ADS)

    Wygant, J. R.; Bonnell, J. W.; Goetz, K.; Ergun, R. E.; Mozer, F. S.; Bale, S. D.; Ludlam, M.; Turin, P.; Harvey, P. R.; Hochmann, R.; Harps, K.; Dalton, G.; McCauley, J.; Rachelson, W.; Gordon, D.; Donakowski, B.; Shultz, C.; Smith, C.; Diaz-Aguado, M.; Fischer, J.; Heavner, S.; Berg, P.; Malsapina, D. M.; Bolton, M. K.; Hudson, M.; Strangeway, R. J.; Baker, D. N.; Li, X.; Albert, J.; Foster, J. C.; Chaston, C. C.; Mann, I.; Donovan, E.; Cully, C. M.; Cattell, C. A.; Krasnoselskikh, V.; Kersten, K.; Brenneman, A.; Tao, J. B.

    2013-11-01

    The Electric Fields and Waves (EFW) Instruments on the two Radiation Belt Storm Probe (RBSP) spacecraft (recently renamed the Van Allen Probes) are designed to measure three dimensional quasi-static and low frequency electric fields and waves associated with the major mechanisms responsible for the acceleration of energetic charged particles in the inner magnetosphere of the Earth. For this measurement, the instrument uses two pairs of spherical double probe sensors at the ends of orthogonal centripetally deployed booms in the spin plane with tip-to-tip separations of 100 meters. The third component of the electric field is measured by two spherical sensors separated by ˜15 m, deployed at the ends of two stacer booms oppositely directed along the spin axis of the spacecraft. The instrument provides a continuous stream of measurements over the entire orbit of the low frequency electric field vector at 32 samples/s in a survey mode. This survey mode also includes measurements of spacecraft potential to provide information on thermal electron plasma variations and structure. Survey mode spectral information allows the continuous evaluation of the peak value and spectral power in electric, magnetic and density fluctuations from several Hz to 6.5 kHz. On-board cross-spectral data allows the calculation of field-aligned wave Poynting flux along the magnetic field. For higher frequency waveform information, two different programmable burst memories are used with nominal sampling rates of 512 samples/s and 16 k samples/s. The EFW burst modes provide targeted measurements over brief time intervals of 3-d electric fields, 3-d wave magnetic fields (from the EMFISIS magnetic search coil sensors), and spacecraft potential. In the burst modes all six sensor-spacecraft potential measurements are telemetered enabling interferometric timing of small-scale plasma structures. In the first burst mode, the instrument stores all or a substantial fraction of the high frequency measurements in a 32 gigabyte burst memory. The sub-intervals to be downloaded are uplinked by ground command after inspection of instrument survey data and other information available on the ground. The second burst mode involves autonomous storing and playback of data controlled by flight software algorithms, which assess the "highest quality" events on the basis of instrument measurements and information from other instruments available on orbit. The EFW instrument provides 3-d wave electric field signals with a frequency response up to 400 kHz to the EMFISIS instrument for analysis and telemetry (Kletzing et al. Space Sci. Rev. 2013).

  9. Performance Testing of Tracer Gas and Tracer Aerosol Detectors for use in Radionuclide NESHAP Compliance Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fuehne, David Patrick; Lattin, Rebecca Renee

    The Rad-NESHAP program, part of the Air Quality Compliance team of LANL’s Compliance Programs group (EPC-CP), and the Radiation Instrumentation & Calibration team, part of the Radiation Protection Services group (RP-SVS), frequently partner on issues relating to characterizing air flow streams. This memo documents the most recent example of this partnership, involving performance testing of sulfur hexafluoride detectors for use in stack gas mixing tests. Additionally, members of the Rad-NESHAP program performed a functional trending test on a pair of optical particle counters, comparing results from a non-calibrated instrument to a calibrated instrument. Prior to commissioning a new stack samplingmore » system, the ANSI Standard for stack sampling requires that the stack sample location must meet several criteria, including uniformity of tracer gas and aerosol mixing in the air stream. For these mix tests, tracer media (sulfur hexafluoride gas or liquid oil aerosol particles) are injected into the stack air stream and the resulting air concentrations are measured across the plane of the stack at the proposed sampling location. The coefficient of variation of these media concentrations must be under 20% when evaluated over the central 2/3 area of the stack or duct. The instruments which measure these air concentrations must be tested prior to the stack tests in order to ensure their linear response to varying air concentrations of either tracer gas or tracer aerosol. The instruments used in tracer gas and aerosol mix testing cannot be calibrated by the LANL Standards and Calibration Laboratory, so they would normally be sent off-site for factory calibration by the vendor. Operational requirements can prevent formal factory calibration of some instruments after they have been used in hazardous settings, e.g., within a radiological facility with potential airborne contamination. The performance tests described in this document are intended to demonstrate the reliable performance of the test instruments for the specific tests used in stack flow characterization.« less

  10. An X-Ray Diffractometer for Mineralogical Analysis of Exomars Mission

    NASA Astrophysics Data System (ADS)

    Marinangeli, L.; Baliva, A.; Critani, F.; Stevoli, A.; Scandelli, L.; Holland, A.; Hutchinson, I.; Nelms, N.; Delhez, R.

    2006-12-01

    The new results of the Mars Exploration Rovers and the Mars Express mission outline the importance of a correct assessment of the variety of geological contexts to understand the evolution of a habitable environment. The need of having complex scientific payload to perform a broad range of in situ measurements is a necessary step for a successful exobiological exploration. Furthermore, the compositional analysis of the surface samples is of fundamental importance to characterize the geological environments where life could have arisen and their evolution through time. In the last years, there has been a strong interest in Europe to develop a x-ray diffractometer (XRD) for mineralogical analyses of planetary surfaces. The identification of minerals using the diffraction technique is based on the x-ray interference with the geometrical parameters of the crystal lattice allowing an unequivocal recognition of different minerals. An US XRD instrument, CHEMIN, will flight for the first time in the NASA Mars Science Laboratory in 2009. An European XRD design has also been selected for the Pasteur Payload of the ESA ExoMars mission, planned for 2011. The proposed instrument is a miniaturised concept (1 kg) configured in a reflection geometry and will allow the identification of a large spectrum of minerals including those related to the presence of water, key element for the development of life. The complete mineralogical analysis will be performed on very small quantities of powder rock samples, thought analysis of pristine (no grinded) sample can also be achieved with the reflection configuration. Information on the elemental composition of the sample can be roughly estimated by the analysis of the x-ray fluorescence spectrum simultaneously acquired by the detection system. In order to demonstrate the instrument technological readiness for the ExoMars mission, the construction of a demonstrative prototype is on going with ESA funding. Preliminary result of the scientific evaluation of the prototype will be shown to assess the capability of the proposed concept in the identification of rock mineralogy. IRSPS and and Laben are respectively the team science coordinator and the engineering responsible for the instrument development. The detector assembly for the prototype has been developed by UK and discussion for the UK involvement on the future instrument development is on going. Delft is providing scientific contribution for the prototype evaluation.

  11. Psychometric Assessment of the Job Embeddedness Instrument: A Rasch Perspective.

    PubMed

    Reitz, O Ed; Smith, Everett V

    2018-05-01

    The aim of this study was to examine the psychometric properties of the job embeddedness instrument (JEI) using a Rasch perspective in a sample of Registered Nurses (RNs). A secondary analysis of data was conducted from a previous study examining the job embeddedness of rural and urban RNs. A Rasch analysis supported the six underlying dimensions: organizational fit, community fit, organizational links, community links, organizational sacrifice, and community sacrifice. The results of this study also demonstrate additional evidence of the validity, reliability, and generalizability of the JEI inferences with a sample of RNs. In total, 38 of 39 items of the original JEI were retained in the model. The psychometric evaluation attained through this multidimensional Rasch analysis provided support for using the JEI to assess the level of job embeddedness for RNs.

  12. Assessing medical professionalism: A systematic review of instruments and their measurement properties

    PubMed Central

    Li, Honghe; Liu, Yang; Wen, Deliang

    2017-01-01

    Background Over the last three decades, various instruments were developed and employed to assess medical professionalism, but their measurement properties have yet to be fully evaluated. This study aimed to systematically evaluate these instruments’ measurement properties and the methodological quality of their related studies within a universally acceptable standardized framework and then provide corresponding recommendations. Methods A systematic search of the electronic databases PubMed, Web of Science, and PsycINFO was conducted to collect studies published from 1990–2015. After screening titles, abstracts, and full texts for eligibility, the articles included in this study were classified according to their respective instrument’s usage. A two-phase assessment was conducted: 1) methodological quality was assessed by following the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) checklist; and 2) the quality of measurement properties was assessed according to Terwee’s criteria. Results were integrated using best-evidence synthesis to look for recommendable instruments. Results After screening 2,959 records, 74 instruments from 80 existing studies were included. The overall methodological quality of these studies was unsatisfactory, with reasons including but not limited to unknown missing data, inadequate sample sizes, and vague hypotheses. Content validity, cross-cultural validity, and criterion validity were either unreported or negative ratings in most studies. Based on best-evidence synthesis, three instruments were recommended: Hisar’s instrument for nursing students, Nurse Practitioners’ Roles and Competencies Scale, and Perceived Faculty Competency Inventory. Conclusion Although instruments measuring medical professionalism are diverse, only a limited number of studies were methodologically sound. Future studies should give priority to systematically improving the performance of existing instruments and to longitudinal studies. PMID:28498838

  13. Coffee aroma: Chemometric comparison of the chemical information provided by three different samplings combined with GC-MS to describe the sensory properties in cup.

    PubMed

    Bressanello, Davide; Liberto, Erica; Cordero, Chiara; Rubiolo, Patrizia; Pellegrino, Gloria; Ruosi, Manuela R; Bicchi, Carlo

    2017-01-01

    This study is part of a wider project aiming to correlate the chemical composition of the coffee volatile fraction to its sensory properties with the end-goal of developing an instrumental analysis approach complementary to human sensory profiling. The proposed investigation strategy compares the chemical information concerning coffee aroma and flavor obtained with HS-SPME of the ground coffee and in-solution SBSE/SPME sampling combined with GC-MS to evaluate their compatibility with the cupping evaluation for quality control purposes. Roasted coffee samples with specific sensory properties were analyzed. The chemical results obtained by the three samplings were compared through multivariate analysis, and related to the samples' sensory attributes. Despite the differences between the three sampling approaches, data processing showed that the three methods provide the same kind of chemical information useful for sample discrimination, and that they could be used interchangeably to sample the coffee aroma and flavor. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Evaluation of correlation between physical properties and ultrasonic pulse velocity of fired clay samples.

    PubMed

    Özkan, İlker; Yayla, Zeliha

    2016-03-01

    The aim of this study is to establish a correlation between physical properties and ultrasonic pulse velocity of clay samples fired at elevated temperatures. Brick-making clay and pottery clay were studied for this purpose. The physical properties of clay samples were assessed after firing pressed clay samples separately at temperatures of 850, 900, 950, 1000, 1050 and 1100 °C. A commercial ultrasonic testing instrument (Proceq Pundit Lab) was used to evaluate the ultrasonic pulse velocity measurements for each fired clay sample as a function of temperature. It was observed that there became a relationship between physical properties and ultrasonic pulse velocities of the samples. The results showed that in consequence of increasing densification of the samples, the differences between the ultrasonic pulse velocities were higher with increasing temperature. These findings may facilitate the use of ultrasonic pulse velocity for the estimation of physical properties of fired clay samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. From Ions to Bits - Developing the IT infrastructure around the CAMECA IMS 1280-HR SIMS lab at GFZ Potsdam

    NASA Astrophysics Data System (ADS)

    Galkin, A.; Klump, J.; Wiedenbeck, M.

    2012-04-01

    Secondary Ion Mass Spectrometers (SIMS) is an highly sensitive technique for analyzing the surfaces of solids and thin film samples, but has the major drawback that such instruments are both rare and expensive. The Virtual SIMS project aims to design, develop and operate the IT infrastructure around the CAMECA IMS 1280-HR SIMS at GFZ Potsdam. The system will cover the whole spectrum of the procedures in the lab - from the online application for measurement time, to the remote access to the instrument and finally the maintenance of the data for publishing and future re-use. A virtual lab infrastructure around the IMS 1280 will enable remote access to the instrument and make measurement time available to the broadest possible user community. Envisioned is that the IT infrastructure would consist of the following: web portal, data repository, sample repository, project management software, communication arrangements between the lab staff and distant researcher and remote access to the instruments. The web portal will handle online applications for the measurement time. The data from the experiments, the monitoring sensor logs and the lab logbook entries are to be stored and archived. Researchers will be able to access their data remotely in real time, thus imposing a user rights management strucuture. Also planned is that all samples and the standards will be assigned a unique International GeoSample Number (IGSN) and that the images of the samples will be stored and made accessible in addition to any additional documents which might be uploaded by the researcher. The project management application will schedule the application process, the measurements times, notifications and alerts. A video conference capability is forseen for communication between the Potsdam staff and the remote researcher. The remote access to the instruments requires a sophisticated client-server solution. This highly sensitive instrument has to be controlled in real-time with latencies diminished to a minimum. Also, failures and shortages of the internet connection, as well as possible outages on the client side, have to be considered and safe fallbacks for such events must be provided. The level of skills of the researcher remotely operating the instrument will define the scope of control given during an operating session. An important aspect of the project is the design of the virtual lab system in collaboration with the laboratory operators and the researchers who will use the instrument and its peripherals. Different approaches for the IT solutions will be tested and evaluated, so imporved guidelines can evolve from obsperved operating performance.

  16. Mothers' attitudes toward adolescent confidential services: development and validation of scales for use in English- and Spanish-speaking populations.

    PubMed

    Tebb, Kathleen P; Pollack, Lance M; Millstein, Shana; Otero-Sabogal, Regina; Wibbelsman, Charles J

    2014-09-01

    To explore parental beliefs and attitudes about confidential services for their teenagers; and to develop an instrument to assess these beliefs and attitudes that could be used among English and Spanish speakers. The long-term goal is to use this research to better understand and evaluate interventions to improve parental knowledge and attitudes toward their adolescent's access and utilization of comprehensive confidential health services. The instrument was developed using an extensive literature review and theoretical framework followed by qualitative data from focus groups and in-depth interviews. It was then pilot tested with a random sample of English- and Spanish-speaking parents and further revised. The final instrument was administered to a random sample of 1,000 mothers. The psychometric properties of the instrument were assessed for Spanish and English speakers. The instrument consisted of 12 scales. Most Cronbach alphas were >.70 for Spanish and English speakers. Fewer items for Spanish speakers "loaded" for the Responsibility and Communication scales. Parental Control of Health Information failed for Spanish speakers. The Parental Attitudes of Adolescent Confidential Health Services Questionnaire (PAACS-Q) contains 12 scales and is a valid and reliable instrument to assess parental knowledge and attitudes toward confidential health services for adolescents among English speakers and all but one scale was applicable for Spanish speakers. More research is needed to understand key constructs with Spanish speakers. Copyright © 2014 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  17. Characterization of a turbomolecular-pumped magnetic sector mass spectrometer

    NASA Technical Reports Server (NTRS)

    Mehta, Narinder K.

    1988-01-01

    A Perkin Elmer MGA-1200, turbomolecular-pumped, magnetic sector, multiple gas analyzer mass spectrometer with modified inlet for fast response was characterized for the analysis of hydrogen, helium, oxygen and argon in nitrogen and helium background gases. This instrument was specially modified for the Vanderberg AFB SLC-6 Hydrogen Disposal Test Program, as a part of the Hydrogen Sampling System (H2S2). Linearity, precision, drift, detection limits and accuracy among other analytical parameters for each of the background gas were studied to evaluate the performance of the instrument. The result demonstrates that H2S2 mass spectrometer is a stable instrument and can be utilized for the quantitative analytical determination of hydrogen, helium, oxygen and argon in nitrogen and helium background gases.

  18. Non-invasive identification of organic materials in historical stringed musical instruments by reflection infrared spectroscopy: a methodological approach.

    PubMed

    Invernizzi, Claudia; Daveri, Alessia; Vagnini, Manuela; Malagodi, Marco

    2017-05-01

    The analysis of historical musical instruments is becoming more relevant and the interest is increasingly moving toward the non-invasive reflection FTIR spectroscopy, especially for the analysis of varnishes. In this work, a specific infrared reflectance spectral library of organic compounds was created with the aim of identifying musical instrument materials in a totally non-invasive way. The analyses were carried out on pure organic compounds, as bulk samples and laboratory wooden models, to evaluate the diagnostic reflection mid-infrared (MIR) bands of proteins, polysaccharides, lipids, and resins by comparing reflection spectra before and after the KK correction. This methodological approach was applied to real case studies represented by four Stradivari violins and a Neapolitan mandolin.

  19. Design, testing and validation of an innovative web-based instrument to evaluate school meal quality.

    PubMed

    Patterson, Emma; Quetel, Anna-Karin; Lilja, Karin; Simma, Marit; Olsson, Linnea; Elinder, Liselotte Schäfer

    2013-06-01

    To develop a feasible, valid, reliable web-based instrument to objectively evaluate school meal quality in Swedish primary schools. The construct 'school meal quality' was operationalized by an expert panel into six domains, one of which was nutritional quality. An instrument was drafted and pilot-tested. Face validity was evaluated by the panel. Feasibility was established via a large national study. Food-based criteria to predict the nutritional adequacy of school meals in terms of fat quality, iron, vitamin D and fibre content were developed. Predictive validity was evaluated by comparing the nutritional adequacy of school menus based on these criteria with the results from a nutritional analysis. Inter-rater reliability was also assessed. The instrument was developed between 2010 and 2012. It is designed for use in all primary schools by school catering and/or management representatives. A pilot-test of eighty schools in Stockholm (autumn 2010) and a further test of feasibility in 191 schools nationally (spring 2011). The four nutrient-specific food-based criteria predicted nutritional adequacy with sensitivity ranging from 0.85 to 1.0, specificity from 0.45 to 1.0 and accuracy from 0.67 to 1.0. The sample in the national study was statistically representative and the majority of users rated the questionnaire positively, suggesting the instrument is feasible. The inter-rater reliability was fair to almost perfect for continuous variables and agreement was ≥ 67 % for categorical variables. An innovative web-based system to comprehensively monitor school meal quality across several domains, with validated questions in the nutritional domain, is available in Sweden for the first time.

  20. Safety climate and attitude as evaluation measures of organizational safety.

    PubMed

    Isla Díaz, R; Díaz Cabrera, D

    1997-09-01

    The main aim of this research is to develop a set of evaluation measures for safety attitudes and safety climate. Specifically it is intended: (a) to test the instruments; (b) to identify the essential dimensions of the safety climate in the airport ground handling companies; (c) to assess the quality of the differences in the safety climate for each company and its relation to the accident rate; (d) to analyse the relationship between attitudes and safety climate; and (e) to evaluate the influences of situational and personal factors on both safety climate and attitude. The study sample consisted of 166 subjects from three airport companies. Specifically, this research was centered on ground handling departments. The factor analysis of the safety climate instrument resulted in six factors which explained 69.8% of the total variance. We found significant differences in safety attitudes and climate in relation to type of enterprise.

  1. Meta-analytic guidelines for evaluating single-item reliabilities of personality instruments.

    PubMed

    Spörrle, Matthias; Bekk, Magdalena

    2014-06-01

    Personality is an important predictor of various outcomes in many social science disciplines. However, when personality traits are not the principal focus of research, for example, in global comparative surveys, it is often not possible to assess them extensively. In this article, we first provide an overview of the advantages and challenges of single-item measures of personality, a rationale for their construction, and a summary of alternative ways of assessing their reliability. Second, using seven diverse samples (Ntotal = 4,263) we develop the SIMP-G, the German adaptation of the Single-Item Measures of Personality, an instrument assessing the Big Five with one item per trait, and evaluate its validity and reliability. Third, we integrate previous research and our data into a first meta-analysis of single-item reliabilities of personality measures, and provide researchers with guidelines and recommendations for the evaluation of single-item reliabilities. © The Author(s) 2013.

  2. Performance on cognitive tests, instrumental activities of daily living and depressive symptoms of a community-based sample of elderly adults in Rio de Janeiro, Brazil

    PubMed Central

    Lima, Christina Martins Borges; Alves, Heloisa Veiga Dias; Mograbi, Daniel Correa; Pereira, Flávia Furtado; Fernandez, Jesus Landeira; Charchat-Fichman, Helenice

    2017-01-01

    Objective To describe the performance on basic cognitive tasks, instrumental activities of daily living, and depressive symptoms of a community-based sample of elderly adults in Rio de Janeiro (Brazil) who participated in multiple physical, social, and cognitive activities at government-run community centers. Methods A total of 264 educated older adults (> 60 years of age of both genders) were evaluated by the Brief Cognitive Screening Battery (BCSB), Lawton's and Pfeffer's activities of daily living indexes, and the Geriatric Depressive Scale (GDS). Results The mean age of the sample was 75.7 years. The participants had a mean of 9.3 years of formal education. With the exception of the Clock Drawing Test (CDT), mean scores on the cognitive tests were consistent with the values in the literature. Only 6.4% of the sample had some kind of dependence for activities of daily living. The results of the Geriatric Depression Scale (GDS-15) indicated mild symptoms of depression in 16.8% of the sample Conclusion This study provided important demographic, cognitive, and functional characteristics of a specific community-based sample of elderly adults in Rio de Janeiro, Brazil. PMID:29213494

  3. Moving your laboratories to the field – Advantages and limitations of the use of field portable instruments in environmental sample analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gałuszka, Agnieszka, E-mail: Agnieszka.Galuszka@ujk.edu.pl; Migaszewski, Zdzisław M.; Namieśnik, Jacek

    The recent rapid progress in technology of field portable instruments has increased their applications in environmental sample analysis. These instruments offer a possibility of cost-effective, non-destructive, real-time, direct, on-site measurements of a wide range of both inorganic and organic analytes in gaseous, liquid and solid samples. Some of them do not require the use of reagents and do not produce any analytical waste. All these features contribute to the greenness of field portable techniques. Several stationary analytical instruments have their portable versions. The most popular ones include: gas chromatographs with different detectors (mass spectrometer (MS), flame ionization detector, photoionization detector),more » ultraviolet–visible and near-infrared spectrophotometers, X-ray fluorescence spectrometers, ion mobility spectrometers, electronic noses and electronic tongues. The use of portable instruments in environmental sample analysis gives a possibility of on-site screening and a subsequent selection of samples for routine laboratory analyses. They are also very useful in situations that require an emergency response and for process monitoring applications. However, quantification of results is still problematic in many cases. The other disadvantages include: higher detection limits and lower sensitivity than these obtained in laboratory conditions, a strong influence of environmental factors on the instrument performance and a high possibility of sample contamination in the field. This paper reviews recent applications of field portable instruments in environmental sample analysis and discusses their analytical capabilities. - Highlights: • Field portable instruments are widely used in environmental sample analysis. • Field portable instruments are indispensable for analysis in emergency response. • Miniaturization of field portable instruments reduces resource consumption. • In situ analysis is in agreement with green analytical chemistry principles. • Performance requirements in field analysis stimulate technological progress.« less

  4. In-vitro comparison of instrumentation time and cleaning capacity between endodontic handpiece and manual preparation techniques in primary molar teeth.

    PubMed

    Seraj, B; Ramezani, G; Ghadimi, S; Mosharrafian, S H; Motahhary, P; Safari, M

    2013-01-01

    The aim of this study was to evaluate and compare the cleaning ability and instrumentation time of manual method and use of endodontic handpiece for preparation of primary molar teeth. Forty primary teeth canals were used in this experimental study. Access cavities were prepared and India ink was injected into the canals. The samples were divided into three groups according to the preparation technique. In the first group the root canals were manually instrumented by k_files. Endodontic handpiece (TEP-ER10, NSK, Japan) were used for canal preparation in the second group and the samples in the third group (control) were not instrumented. After preparing the canal, the teeth were cleared with methyl salicylate and the removal of India ink was measured in the cervical, middle and apical thirds. The instrumentation time was transcribed by chronometer. Statistical analysis was performed using Mann-Whitney and t-test. There was no significant difference in cleaning capacity between the two techniques, but results of the first and second group differ from those of the control group. In fact, time taken for preparation was significantly shorter with endodontic handpiece system. Seen the shorter working time of endodontic handpiece and the similar cleaning ability of the two techniques, the application of the endodontic handpiece is recommended for preparation of deciduous root canals during pulpectomy.

  5. Estimating Sampling Biases and Measurement Uncertainties of AIRS-AMSU-A Temperature and Water Vapor Observations Using MERRA Reanalysis

    NASA Technical Reports Server (NTRS)

    Hearty, Thomas J.; Savtchenko, Andrey K.; Tian, Baijun; Fetzer, Eric; Yung, Yuk L.; Theobald, Michael; Vollmer, Bruce; Fishbein, Evan; Won, Young-In

    2014-01-01

    We use MERRA (Modern Era Retrospective-Analysis for Research Applications) temperature and water vapor data to estimate the sampling biases of climatologies derived from the AIRS/AMSU-A (Atmospheric Infrared Sounder/Advanced Microwave Sounding Unit-A) suite of instruments. We separate the total sampling bias into temporal and instrumental components. The temporal component is caused by the AIRS/AMSU-A orbit and swath that are not able to sample all of time and space. The instrumental component is caused by scenes that prevent successful retrievals. The temporal sampling biases are generally smaller than the instrumental sampling biases except in regions with large diurnal variations, such as the boundary layer, where the temporal sampling biases of temperature can be +/- 2 K and water vapor can be 10% wet. The instrumental sampling biases are the main contributor to the total sampling biases and are mainly caused by clouds. They are up to 2 K cold and greater than 30% dry over mid-latitude storm tracks and tropical deep convective cloudy regions and up to 20% wet over stratus regions. However, other factors such as surface emissivity and temperature can also influence the instrumental sampling bias over deserts where the biases can be up to 1 K cold and 10% wet. Some instrumental sampling biases can vary seasonally and/or diurnally. We also estimate the combined measurement uncertainties of temperature and water vapor from AIRS/AMSU-A and MERRA by comparing similarly sampled climatologies from both data sets. The measurement differences are often larger than the sampling biases and have longitudinal variations.

  6. In vitro evaluation of apical extrusion of bacteria following use of new rotary instrumentation system.

    PubMed

    Mohammadi, Zahed

    2009-04-01

    The aim of this study was to evaluate the number of bacteria extruded apically from extracted teeth ex vivo after canal instrumentation using two engine-driven nickel-titanium instruments (Flex Master and V-Taper). Seventy extracted maxillary central incisor teeth were used. After preparing access cavities, root canals were contaminated with a suspension of Enterococcus faecalis, then dried. The contaminated roots were divided into two experimental groups of 30 teeth each and one control group of 10 teeth. Bacteria extruded from the apical foramen during instrumentation were collected into vials. The microbiological samples from the vials were incubated in culture media for 24 hours. Colonies of bacteria were counted, and the results were given as number of colony-forming units. The data obtained were analyzed using the Kruskal-Wallis one-way analysis of variance and Mann-Whitney U-tests, with alpha = 0.05 as the level for statistical significance. Results showed that there was no significant difference as to the number of extruded bacteria between the two engine-driven systems (P > 0.05). Both engine-driven nickel-titanium systems extruded bacteria through the apical foramen.

  7. Development Of Methodologies Using PhabrOmeter For Fabric Drape Evaluation

    NASA Astrophysics Data System (ADS)

    Lin, Chengwei

    Evaluation of fabric drape is important for textile industry as it reveals the aesthetic and functionality of the cloth and apparel. Although many fabric drape measuring methods have been developed for several decades, they are falling behind the need for fast product development by the industry. To meet the requirement of industries, it is necessary to develop an effective and reliable method to evaluate fabric drape. The purpose of the present study is to determine if PhabrOmeter can be applied to fabric drape evaluation. PhabrOmeter is a fabric sensory performance evaluating instrument which is developed to provide fast and reliable quality testing results. This study was sought to determine the relationship between fabric drape and other fabric attributes. In addition, a series of conventional methods including AATCC standards, ASTM standards and ISO standards were used to characterize the fabric samples. All the data were compared and analyzed with linear correlation method. The results indicate that PhabrOmeter is reliable and effective instrument for fabric drape evaluation. Besides, some effects including fabric structure, testing directions were considered to examine their impact on fabric drape.

  8. Continuous flow electrophoresis system experiments on shuttle flights STS-6 and STS-7

    NASA Technical Reports Server (NTRS)

    Snyder, Robert S.; Rhodes, Percy H.; Miller, Teresa Y.

    1988-01-01

    The development of a space continuous flow electrophoresis system (CFES) is discussed. The objectives of the experiment were: (1) to use a model sample material at a high concentration to evaluate the continuous flow electrophoresis process in the McDonnell Douglass CFES instrument and compare its separation resolution and sample throughput with related devices on Earth, and (2) to expand the basic knowledge of the limitations imposed by fluid flows and particle concentration effects on the electrophoresis process by careful design and evaluation of the space experiment. Hemoglobin and polysaccharide were selected as samples of concentration effects. The results from space show a large band spread of the high concentration of the single species of hemoglobin that was principally due to the mismatch of electrical conductivity between the sample and buffer.

  9. Integrated sampling and analysis unit for the determination of sexual pheromones in environmental air using fabric phase sorptive extraction and headspace-gas chromatography-mass spectrometry.

    PubMed

    Alcudia-León, M Carmen; Lucena, Rafael; Cárdenas, Soledad; Valcárcel, Miguel; Kabir, Abuzar; Furton, Kenneth G

    2017-03-10

    This article presents a novel unit that integrates for the first time air sampling and preconcentration based on the use of fabric phase sorptive extraction principles. The determination of Tuta absoluta sexual pheromone traces in environmental air has been selected as analytical problem. For this aim, a novel laboratory-built unit made up of commercial brass elements as holder of the sol-gel coated fabric extracting phase has been designed and optimized. The performance of the integrated unit was evaluated analyzing environmental air sampled in tomato crops. The unit can work under sampling and analysis mode which eliminates any need for sorptive phase manipulation prior to instrumental analysis. In the sampling mode, the unit can be connected to a sampling pump to pass the air through the sorptive phase at a controlled flow-rate. In the analysis mode, it is placed in the gas chromatograph autosampler without any instrumental modification. It also diminishes the risk of cross contamination between sampling and analysis. The performance of the new unit has been evaluated using the main components of the sexual pheromone of Tuta absoluta [(3E,8Z,11Z)-tetradecatrien-1-yl acetate and (3E,8Z)-tetradecadien-1-yl acetate] as model analytes. The limits of detection for both compounds resulted to be 1.6μg and 0.8μg, respectively, while the precision (expressed as relative standard deviation) was better than 3.7%. Finally, the unit has been deployed in the field to analyze a number of real life samples, some of them were found positive. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Fully automated, internally controlled quantification of hepatitis B Virus DNA by real-time PCR by use of the MagNA Pure LC and LightCycler instruments.

    PubMed

    Leb, Victoria; Stöcher, Markus; Valentine-Thon, Elizabeth; Hölzl, Gabriele; Kessler, Harald; Stekel, Herbert; Berg, Jörg

    2004-02-01

    We report on the development of a fully automated real-time PCR assay for the quantitative detection of hepatitis B virus (HBV) DNA in plasma with EDTA (EDTA plasma). The MagNA Pure LC instrument was used for automated DNA purification and automated preparation of PCR mixtures. Real-time PCR was performed on the LightCycler instrument. An internal amplification control was devised as a PCR competitor and was introduced into the assay at the stage of DNA purification to permit monitoring for sample adequacy. The detection limit of the assay was found to be 200 HBV DNA copies/ml, with a linear dynamic range of 8 orders of magnitude. When samples from the European Union Quality Control Concerted Action HBV Proficiency Panel 1999 were examined, the results were found to be in acceptable agreement with the HBV DNA concentrations of the panel members. In a clinical laboratory evaluation of 123 EDTA plasma samples, a significant correlation was found with the results obtained by the Roche HBV Monitor test on the Cobas Amplicor analyzer within the dynamic range of that system. In conclusion, the newly developed assay has a markedly reduced hands-on time, permits monitoring for sample adequacy, and is suitable for the quantitative detection of HBV DNA in plasma in a routine clinical laboratory.

  11. Simulation of a suite of generic long-pulse neutron instruments to optimize the time structure of the European Spallation Source.

    PubMed

    Lefmann, Kim; Klenø, Kaspar H; Birk, Jonas Okkels; Hansen, Britt R; Holm, Sonja L; Knudsen, Erik; Lieutenant, Klaus; von Moos, Lars; Sales, Morten; Willendrup, Peter K; Andersen, Ken H

    2013-05-01

    We here describe the result of simulations of 15 generic neutron instruments for the long-pulsed European Spallation Source. All instruments have been simulated for 20 different settings of the source time structure, corresponding to pulse lengths between 1 ms and 2 ms; and repetition frequencies between 10 Hz and 25 Hz. The relative change in performance with time structure is given for each instrument, and an unweighted average is calculated. The performance of the instrument suite is proportional to (a) the peak flux and (b) the duty cycle to a power of approximately 0.3. This information is an important input to determining the best accelerator parameters. In addition, we find that in our simple guide systems, most neutrons reaching the sample originate from the central 3-5 cm of the moderator. This result can be used as an input in later optimization of the moderator design. We discuss the relevance and validity of defining a single figure-of-merit for a full facility and compare with evaluations of the individual instrument classes.

  12. Initial evaluation of psychometric properties of a structured work task application for the Assessment of Work Performance in a constructed environment.

    PubMed

    Karlsson, Elin A; Liedberg, Gunilla M; Sandqvist, Jan L

    2017-06-22

    The Swedish Social Insurance Administration has developed a new assessment tool for sickness insurance. This study is a part of the initial evaluation of the application, called the Assessment of Work Performance, Structured Activities, and focuses on evaluation of the psychometric properties of social validity, content validity, and utility. This was a qualitative study using semi-structured telephone interviews with occupational therapists. A convenience sample was used and participants who fulfilled inclusion criteria (n = 15) were interviewed. Data were analyzed using content analysis with a directed approach. The results indicate that the application provides valuable information and that it is socially valid. Assessors found work tasks suitable for a diverse group of clients and reported that clients accepted the assessments. Improvements were suggested, for example, expanding the application with more work tasks. The instrument has benefits; however, further development is desired. The use of a constructed environment in assessments may be a necessary option to supplement a real environment. But depending on organizational factors such as time and other resources, the participants had different opportunities to do so. Further evaluations regarding ecological validity are essential to ensure that assessments are fair and realistic when using constructed environments. Implications for rehabilitation This study indicates that assessment in a constructed environment can provide a secure and protected context for clients being assessed. Psychometric evaluations are a never-ending process and this assessment instrument needs further development. However, this initial evaluation provides guidance in development of the instrument but also what studies to give priority to. It is important to evaluate social validity in order to ensure that clients and assessors perceive assessment methods fair and meaningful. In this study, participants found the work tasks appropriate and usable when assessing their clients but client's perspective must also be included in following studies. This assessment instrument is the only activity-based assessment instrument within the Swedish Social Security Insurance. Psychometric evaluations are important since it affects so many individuals in Sweden.

  13. Cryopyrin-associated periodic syndromes: development of a patient-reported outcomes instrument to assess the pattern and severity of clinical disease activity.

    PubMed

    Hoffman, Hal M; Wolfe, Frederick; Belomestnov, Pavel; Mellis, Scott J

    2008-09-01

    Development of an instrument for characterization of symptom patterns and severity in patients with cryopyrin-associated periodic syndromes (CAPS). Two generations of daily health assessment forms (DHAFs) were evaluated in this study. The first-generation DHAF queried 11 symptoms. Analyses of results obtained with that instrument identified five symptoms included in a revised second-generation DHAF that was tested for internal consistency and test-retest reliability. This DHAF was also assessed during the initial portion of a phase 3 clinical study of CAPS treatment. Forty-eight CAPS patients provided data for the first-generation DHAFs. Five symptoms (rash, fever, joint pain, eye redness/pain, and fatigue) were included in the revised second-generation DHAF. Symptom severity was highly variable during all study phases with as many as 89% of patients reporting at least one symptom flare, and percentages of days with flares reaching 58% during evaluation of the second-generation instrument. Mean composite key symptom scores (KSSs) computed during evaluation of the second-generation DHAF correlated well with Physician's Global Assessment of Disease Activity (r=0.91, p<0.0001) and patient reports of limitations of daily activities (r=0.68, p<0.0001). Test-retest reliability and Cronbach's alpha's were high (0.93 and 0.94, respectively) for the second-generation DHAF. Further evaluation of this DHAF during a baseline period and placebo treatment in a phase 3 clinical study of CAPS patients indicated strong correlations between baseline KSS and Physician's Global Assessment of Disease Activity. Cronbach's alpha's at baseline and test-retest reliability were also high. Potentially important study limitations include small sample size, the lack of a standard tool for CAPS symptom assessment against which to validate the DHAF, and no assessment of the instrument's responsivity to CAPS therapy. The DHAF is a new instrument that may be useful for capturing symptom patterns and severity in CAPS patients and monitoring responses to therapies for these conditions.

  14. Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement.

    PubMed

    De-Deus, G; Moreira, E J L; Lopes, H P; Elias, C N

    2010-12-01

    To evaluate the cyclic fatigue fracture resistance of engine-driven F2 ProTaper instruments under reciprocating movement. A sample of 30 NiTi ProTaper F2 instruments was used. An artificial canal was made from a stainless steel tube, allowing the instruments to rotate freely. During mechanical testing, different movement kinematics and speeds were used, which resulted in three experimental groups (n = 10). The instruments from the first group (G1) were rotated at a nominal speed of 250 rpm until fracture, whilst the instruments from the second group (G2) were rotated at 400 rpm. In the third instrument group (G3), the files were driven under reciprocating movement. The time of fracture for each instrument was measured, and statistical analysis was performed using parametric methods. Reciprocating movement resulted in a significantly longer cyclic fatigue life (P < 0.05). Moreover, operating rpm was a significant factor affecting cyclic fatigue life (P < 0.05); instruments used at a rotational speed of 400 rpm (approximately 95 s) failed more rapidly than those used at 250 rpm (approximately 25 s). Movement kinematics is amongst the factors determining the resistance of rotary NiTi instruments to cyclic fracture. Moreover, the reciprocating movement promoted an extended cyclic fatigue life of the F2 ProTaper instrument in comparison with conventional rotation.

  15. Nanophase Carbonates on Mars: Does Evolved Gas Analysis of Nanophase Carbonates Reveal a Large Organic Carbon Budget in Near-Surface Martian Materials?

    NASA Technical Reports Server (NTRS)

    Archer, P. Douglas, Jr.; Niles, Paul B.; Ming, Douglas W.; Sutter, Brad; Eigenbrode, Jen

    2015-01-01

    Evolved Gas Analysis (EGA), which involves heating a sample and monitoring the gases released, has been performed on Mars by the Viking gas chromatography/mass spectrometry instruments, the Thermal and Evolved Gas Analyzer (TEGA) on the Phoenix lander, and the Sample Analysis at Mars (SAM) instrument on the Mars Science Laboratory. All of these instruments detected CO2 released during sample analysis at abundances of approx. 0.1 to 5 wt% assuming a carbonate source. The source of the CO2 can be constrained by evaluating the temperature of the gas release, a capability of both the TEGA and SAM instruments. The samples analyzed by SAM show that the majority of the CO2 is released below 400C, much lower than traditional carbonate decomposition temperatures which can be as low as 400C for some siderites, with magnesites and calcites decomposing at even higher temperatures. In addition to mineralogy, decomposition temperature can depend on particle size (among other factors). If carbonates formed on Mars under low temperature and relative humidity conditions, the resulting small particle size (nanophase) carbonates could have low decomposition temperatures. We have found that calcite can be synthesized by exposing CaO to water vapor and CO2 and that the resulting mineral has an EGA peak of approx. 550C for CO2, which is about 200C lower than for other calcites. Work is ongoing to produce Fe and Mg-bearing carbonates using the same process. Current results suggest that nanophase calcium carbonates cannot explain the CO2 released from martian samples. If the decomposition temperatures of Mg and Fe-bearing nanophase carbonates are not significantly lower than 400C, other candidate sources include oxalates and carboxylated organic molecules. If present, the abundance of organic carbon in these samples could be greater than 0.1 wt % (1000s of ppm), a signficant departure from the paradigm of the organic-poor Mars based on Viking results.

  16. Validation of World Health Organization Assessment Schedule 2.0 in specialized somatic rehabilitation services in Norway.

    PubMed

    Moen, Vegard Pihl; Drageset, Jorunn; Eide, Geir Egil; Klokkerud, Mari; Gjesdal, Sturla

    2017-02-01

    The World Health Organization Disability Assessment Schedule (WHODAS) 2.0 is a generic instrument to assess disability covering six domains. The purpose of this study was to investigate the potential of the instrument for monitoring disability in specialized somatic rehabilitation by testing reliability, construct validity and responsiveness of WHODAS 2.0, Norwegian version, among patients with various health conditions. For taxonomy, terminology and definitions, the Consensus-based Standards for the Selection of Health Measurement Instruments were followed. Reproducibility was investigated by the intra-class correlation coefficient (ICC) in a randomly selected sample. Internal consistency was assessed by Cronbach's alpha. Construct validity was evaluated by correlations between WHODAS 2.0 and the Medical Outcomes Study 36-item Short Form, and fit of the hypothesized structure using confirmatory factor analysis (CFA). Responsiveness was evaluated in another randomly selected sample by testing a priori formulated hypotheses. Nine hundred seventy patients were included in the study. Reproducibility and responsiveness were evaluated in 53 and 104 patients, respectively. The ICC for the WHODAS 2.0 domains ranged from 0.63 to 0.84 and was 0.87 for total score. Cronbach's alpha for domains ranged from 0.75 to 0.94 and was 0.93 for total score. For construct validity, 6 of 12 expected correlations were confirmed and CFA did not achieve satisfactory fit indices. For responsiveness, 3 of 8 hypotheses were confirmed. The Norwegian version of WHODAS 2.0 showed moderate to satisfactory reliability and moderate validity in rehabilitation patients. However, the present study indicated possible limitations in terms of responsiveness.

  17. Instruments evaluating the self-directed learning abilities among nursing students and nurses: a systematic review of psychometric properties.

    PubMed

    Cadorin, Lucia; Bressan, Valentina; Palese, Alvisa

    2017-11-25

    Modern healthcare institutions are continuously changing, and Self-Directed Learning (SDL) abilities are considered a prerequisite for both nursing students and nurses in order to be proactive about these demanding challenges. To date, no systematic reviews of existing instruments aimed at detecting and critically evaluating SDL abilities have been published. Therefore, the aims of this review are: 1) identify the instruments for assessment of SDL abilities among nursing students and nurses; 2) critically evaluate the methodological studies quality; and 3) compare the psychometric properties of the available instruments. A psychometric-systematic-review was performed. CDSR, CINAHL, ERIC, MEDLINE, PROSPERO, SCOPUS databases were searched without restrictions in time and setting. All primary studies involving nursing students or nurses, written in English and aimed at validating SDL assessment tools, were included. Studies retrieved were evaluated according to the COnsensus-based-Standards for the selection of health Measurement-INstruments (COSMIN) panel. Study inclusion, data extraction and quality assessment were performed by researchers independently. Eleven studies were included and four tools based on Knowles's theory have emerged: 1) the Self-Directed Learning Readiness Scale; 2) the Self-Directed Learning Readiness Scale for Nursing Education; 3) the Self-Rating Scale of Self-Directed Learning, and 4) the Self-Directed Learning Instrument. A few psychometric properties have been considered in each study, from two to four out of the ten required. The quality of the methodologies used was in general, from fair to poor with the exception of one instrument (the Self-Directed-Learning-Instrument). The psychometric proprieties that emerged across the tools were good in general: the Cronbach α was from 0.73 to 0.91; structural validities have also reported good indexes both in the explorative and in the confirmative factor analyses. On the basis of the findings, the Self-Directed-Learning-Instrument can be recommended for the assessment of SDL abilities among nursing students and nurses, given the excellent methodology quality adopted in estimating the psychometric properties. However, rigorous study designs aimed at estimating psychometric properties of tools in wide samples of nursing students and nurses across different stages of professional life, from undergraduate education to professional maturity, in different cultural, educational, and work settings, are strongly recommended.

  18. Color compensation in nitrite-reduced meat batters incorporating paprika or tomato paste.

    PubMed

    Bázan-Lugo, Eduardo; García-Martínez, Ignacio; Alfaro-Rodríguez, Rosa Hayde; Totosaus, Alfonso

    2012-06-01

    Nitrite is a key ingredient the manufacture of meat products, forming a stable pink color characteristic of cured products, retarding the development of rancidity and off-odors and flavors during storage, and preventing microbial growth. The negative aspects of nitrite and the demands for healthy foods result in the need to reduce nitrite in cured meat products. Paprika or tomato has been employed as natural pigments in meat products. The objective of this work was to determine the effect of incorporating paprika powder or tomato paste on the texture, rancidity and instrumental and sensory color compensation in nitrite-reduced meat batters. Addition of tomato paste improved moisture content, resulting in harder but less cohesive samples as compared to control and paprika-containing meat batters. Color characteristics of reduced nitrite samples obtained higher a* red coloration (8.9 for paprika and 7.7-8.0 for tomato paste), as compared to control samples (5.65). Instrumental color was low in control samples, with high values for tomato paste and paprika samples. Nonetheless, tomato paste used to compensate color in nitrite-reduced meat batters was ranked closer to the control sample in sensory evaluation. Color characteristics-instrumental and sensory-in these kinds of meat products were enhanced by the addition of 2.5-3.0% of tomato paste, presenting results close to the non-reduced nitrite control. Similarly, antioxidant components of tomato paste or paprika reduced lipid oxidation. Nitrite reduction from 150 to 100 ppm could be achieved employing tomato paste as a natural pigment to improve color and texture. Copyright © 2011 Society of Chemical Industry.

  19. Nanopore sequencing in microgravity

    PubMed Central

    McIntyre, Alexa B R; Rizzardi, Lindsay; Yu, Angela M; Alexander, Noah; Rosen, Gail L; Botkin, Douglas J; Stahl, Sarah E; John, Kristen K; Castro-Wallace, Sarah L; McGrath, Ken; Burton, Aaron S; Feinberg, Andrew P; Mason, Christopher E

    2016-01-01

    Rapid DNA sequencing and analysis has been a long-sought goal in remote research and point-of-care medicine. In microgravity, DNA sequencing can facilitate novel astrobiological research and close monitoring of crew health, but spaceflight places stringent restrictions on the mass and volume of instruments, crew operation time, and instrument functionality. The recent emergence of portable, nanopore-based tools with streamlined sample preparation protocols finally enables DNA sequencing on missions in microgravity. As a first step toward sequencing in space and aboard the International Space Station (ISS), we tested the Oxford Nanopore Technologies MinION during a parabolic flight to understand the effects of variable gravity on the instrument and data. In a successful proof-of-principle experiment, we found that the instrument generated DNA reads over the course of the flight, including the first ever sequenced in microgravity, and additional reads measured after the flight concluded its parabolas. Here we detail modifications to the sample-loading procedures to facilitate nanopore sequencing aboard the ISS and in other microgravity environments. We also evaluate existing analysis methods and outline two new approaches, the first based on a wave-fingerprint method and the second on entropy signal mapping. Computationally light analysis methods offer the potential for in situ species identification, but are limited by the error profiles (stays, skips, and mismatches) of older nanopore data. Higher accuracies attainable with modified sample processing methods and the latest version of flow cells will further enable the use of nanopore sequencers for diagnostics and research in space. PMID:28725742

  20. Cross-Validation of Levenson's Psychopathy Scale in a Sample of Federal Female Inmates

    ERIC Educational Resources Information Center

    Brinkley, Chad A.; Diamond, Pamela M.; Magaletta, Philip R.; Heigel, Caron P.

    2008-01-01

    Levenson, Kiehl, and Fitzpatrick's Self-Report Psychopathy Scale (LSRPS) is evaluated to determine the factor structure and concurrent validity of the instrument among 430 federal female inmates. Confirmatory factor analysis fails to validate the expected 2-factor structure. Subsequent exploratory factor analysis reveals a 3-factor structure…

  1. An Examination of the Validity of Two Measures of Student Engagement

    ERIC Educational Resources Information Center

    Reschly, Amy L.; Betts, Joseph; Appleton, James J.

    2014-01-01

    This study evaluated the psychometric properties of two measures of student engagement, the Student Engagement Instrument (SEI) and the Motivation-Engagement Scale (MES), with adolescents in the southeastern United States. Confirmatory factor analyses revealed an acceptable fit of the SEI and a relatively poor fit of the MES in this sample.…

  2. Academic Performance and Perceived Stress among University Students

    ERIC Educational Resources Information Center

    Talib, Nadeem; Zia-ur-Rehman, Muhammad

    2012-01-01

    This study aims to investigate the effect of factor such as perceived stress on the academic performance of the students. A sample of 199 university graduates and undergraduates in Rawalpindi and Islamabad was selected as a statistical frame. Instrumentation used for this study is previously validated construct in order to evaluate the effect of…

  3. Development of a Drug Use Resistance Self-Efficacy (DURSE) Scale

    ERIC Educational Resources Information Center

    Carpenter, Carrie M.; Howard, Donna

    2009-01-01

    Objectives: To develop and evaluate psychometric properties of a new instrument, the drug use resistance self-efficacy (DURSE) scale, designed for young adolescents. Methods: Scale construction occurred in 3 phases: (1) initial development, (2) pilot testing of preliminary items, and (3) final scale administration among a sample of seventh graders…

  4. The Content of Education for Direct Caregivers

    ERIC Educational Resources Information Center

    Kusmaul, Nancy

    2016-01-01

    Direct caregivers in nursing homes are the certified nursing assistants (CNAs) who provide the majority of hands-on care. This study administered a knowledge instrument to a sample of CNAs () employed at nursing homes in a northeastern city to evaluate their knowledge in the domains of aging, cognition, and mental health. This study found that…

  5. Follow Through Classroom Process Measurement and Pupil Growth (1970-71). Final Report.

    ERIC Educational Resources Information Center

    Soar, Robert S.

    This study presents results from the last year of a three-year adjunctive evaluation of classroom process measurement and pupil growth. A total of 289 classrooms involving eight experimental programs, ranging from open classrooms to contingency management classes, along with a comparison sample, were observed. Four observation instruments were…

  6. Linear model correction: A method for transferring a near-infrared multivariate calibration model without standard samples.

    PubMed

    Liu, Yan; Cai, Wensheng; Shao, Xueguang

    2016-12-05

    Calibration transfer is essential for practical applications of near infrared (NIR) spectroscopy because the measurements of the spectra may be performed on different instruments and the difference between the instruments must be corrected. For most of calibration transfer methods, standard samples are necessary to construct the transfer model using the spectra of the samples measured on two instruments, named as master and slave instrument, respectively. In this work, a method named as linear model correction (LMC) is proposed for calibration transfer without standard samples. The method is based on the fact that, for the samples with similar physical and chemical properties, the spectra measured on different instruments are linearly correlated. The fact makes the coefficients of the linear models constructed by the spectra measured on different instruments are similar in profile. Therefore, by using the constrained optimization method, the coefficients of the master model can be transferred into that of the slave model with a few spectra measured on slave instrument. Two NIR datasets of corn and plant leaf samples measured with different instruments are used to test the performance of the method. The results show that, for both the datasets, the spectra can be correctly predicted using the transferred partial least squares (PLS) models. Because standard samples are not necessary in the method, it may be more useful in practical uses. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. TANK VAPOR CHEMICALS OF POTENTIAL CONCERN & EXISTING DIRECT READING INSTRUMENTION & PERSONAL PROTECTIVE EQUIPMENT CONSIDERATIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BUTLER, N.K.

    2004-11-01

    This document takes the newly released Industrial Hygiene Chemical Vapor Technical Basis (RPP-22491) and evaluates the chemicals of potential concern (COPC) identified for selected implementation actions by the industrial hygiene organization. This document is not intended as a hazard analysis with recommended controls for all tank farm activities. Not all of the chemicals listed are present in all tanks; therefore, hazard analyses can and should be tailored as appropriate. Detection of each chemical by current industrial hygiene non-specific instrumentation in use at the tank farms is evaluated. Information gaps are identified and recommendations are made to resolve these needs. Ofmore » the 52 COPC, 34 can be detected with existing instrumentation. Three additional chemicals could be detected with a photoionization detector (PID) equipped with a different lamp. Discussion with specific instrument manufacturers is warranted. Consideration should be given to having the SapphIRe XL customized for tank farm applications. Other instruments, sampling or modeling techniques should be evaluated to estimate concentrations of chemicals not detected by direct reading instruments. In addition, relative instrument response needs to be factored in to action levels used for direct reading instruments. These action levels should be correlated to exposures to the COPC and corresponding occupational exposure limits (OELs). The minimum respiratory protection for each of the COPC is evaluated against current options. Recommendations are made for respiratory protection based on each chemical. Until exposures are sufficiently quantified and analyzed, the current use of supplied air respiratory protection is appropriate and protective for the COPC. Use of supplied air respiratory protection should be evaluated once a detailed exposure assessment for the COPC is completed. The established tank farm OELs should be documented in the TFC-PLN-34. For chemicals without an established tank farm OEL, consideration should be given to adopting protective limits from NIOSH, AIHA, or developing OELs. Protective gloves and suits are evaluated for each chemical for which information is available. Information gaps are identified for some of the compounds and materials. Recommendations are made for resolving these needs. Based on available information, Silver Shield{reg_sign} gloves are promising for tank farm applications. However, permeation testing documentation is needed for the COPC and mixtures for Silver Shield{reg_sign} gloves to evaluate their protectiveness. North Safety Products is expected to provide the requested documentation. Multiple Tychem{reg_sign} products are available. There is overlap between chemicals and effective materials. Further hazard evaluation to determine actual hazards and permeation testing documentation is required to assess the efficacy of a single Tychem{reg_sign} product for tank farm applications. All of this chemical specific data is combined into a spreadsheet that will assist the industrial hygienist in the selection of monitoring instruments, respiratory protection selection and protective clothing for performing work at a specific tank(s).« less

  8. [Evaluation of measurement uncertainty of welding fume in welding workplace of a shipyard].

    PubMed

    Ren, Jie; Wang, Yanrang

    2015-12-01

    To evaluate the measurement uncertainty of welding fume in the air of the welding workplace of a shipyard, and to provide quality assurance for measurement. According to GBZ/T 192.1-2007 "Determination of dust in the air of workplace-Part 1: Total dust concentration" and JJF 1059-1999 "Evaluation and expression of measurement uncertainty", the uncertainty for determination of welding fume was evaluated and the measurement results were completely described. The concentration of welding fume was 3.3 mg/m(3), and the expanded uncertainty was 0.24 mg/m(3). The repeatability for determination of dust concentration introduced an uncertainty of 1.9%, the measurement using electronic balance introduced a standard uncertainty of 0.3%, and the measurement of sample quality introduced a standard uncertainty of 3.2%. During the determination of welding fume, the standard uncertainty introduced by the measurement of sample quality is the dominant uncertainty. In the process of sampling and measurement, quality control should be focused on the collection efficiency of dust, air humidity, sample volume, and measuring instruments.

  9. A comparison of dental ultrasonic technologies on subgingival calculus removal: a pilot study.

    PubMed

    Silva, Lidia Brión; Hodges, Kathleen O; Calley, Kristin Hamman; Seikel, John A

    2012-01-01

    This pilot study compared the clinical endpoints of the magnetostrictive and piezoelectric ultrasonic instruments on calculus removal. The null hypothesis stated that there is no statistically significant difference in calculus removal between the 2 instruments. A quasi-experimental pre- and post-test design was used. Eighteen participants were included. The magnetostrictive and piezoelectric ultrasonic instruments were used in 2 assigned contra-lateral quadrants on each participant. A data collector, blind to treatment assignment, assessed the calculus on 6 predetermined tooth sites before and after ultrasonic instrumentation. Calculus size was evaluated using ordinal measurements on a 4 point scale (0, 1, 2, 3). Subjects were required to have size 2 or 3 calculus deposit on the 6 predetermined sites. One clinician instrumented the pre-assigned quadrants. A maximum time of 20 minutes of instrumentation was allowed with each technology. Immediately after instrumentation, the data collector then conducted the post-test calculus evaluation. The repeated analysis of variance (ANOVA) was used to analyze the pre- and post-test calculus data (p≤0.05). The null hypothesis was accepted indicating that there is no statistically significant difference in calculus removal when comparing technologies (p≤0.05). Therefore, under similar conditions, both technologies removed the same amount of calculus. This research design could be used as a foundation for continued research in this field. Future studies include implementing this study design with a larger sample size and/or modifying the study design to include multiple clinicians who are data collectors. Also, deposit removal with periodontal maintenance patients could be explored.

  10. Lunar and Planetary Science XXXV: Missions and Instruments: Hopes and Hope Fulfilled

    NASA Technical Reports Server (NTRS)

    2004-01-01

    The titles in this section include: 1) Mars Global Surveyor Mars Orbiter Camera in the Extended Mission: The MOC Toolkit; 2) Mars Odyssey THEMIS-VIS Calibration; 3) Early Science Operations and Results from the ESA Mars Express Mission: Focus on Imaging and Spectral Mapping; 4) The Mars Express/NASA Project at JPL; 5) Beagle 2: Mission to Mars - Current Status; 6) The Beagle 2 Microscope; 7) Mars Environmental Chamber for Dynamic Dust Deposition and Statics Analysis; 8) Locating Targets for CRISM Based on Surface Morphology and Interpretation of THEMIS Data; 9) The Phoenix Mission to Mars; 10) First Studies of Possible Landing Sites for the Phoenix Mars Scout Mission Using the BMST; 11) The 2009 Mars Telecommunications Orbiter; 12) The Aurora Exploration Program - The ExoMars Mission; 13) Electron-induced Luminescence and X-Ray Spectrometer (ELXS) System Development; 14) Remote-Raman and Micro-Raman Studies of Solid CO2, CH4, Gas Hydrates and Ice; 15) The Compact Microimaging Spectrometer (CMIS): A New Tool for In-Situ Planetary Science; 16) Preliminary Results of a New Type of Surface Property Measurement Ideal for a Future Mars Rover Mission; 17) Electrodynamic Dust Shield for Solar Panels on Mars; 18) Sensor Web for Spatio-Temporal Monitoring of a Hydrological Environment; 19) Field Testing of an In-Situ Neutron Spectrometer for Planetary Exploration: First Results; 20) A Miniature Solid-State Spectrometer for Space Applications - Field Tests; 21) Application of Laser Induced Breakdown Spectroscopy (LIBS) to Mars Polar Exploration: LIBS Analysis of Water Ice and Water Ice/Soil Mixtures; 22) LIBS Analysis of Geological Samples at Low Pressures: Application to Mars, the Moon, and Asteroids; 23) In-Situ 1-D and 2-D Mapping of Soil Core and Rock Samples Using the LIBS Long Spark; 24) Rocks Analysis at Stand Off Distance by LIBS in Martian Conditions; 25) Evaluation of a Compact Spectrograph/Detection System for a LIBS Instrument for In-Situ and Stand-Off Detection; 26) Analysis of Organic Compounds in Mars Analog Samples; 27) Report of the Organic Contamination Science Steering Group; 28) The Water-Wheel IR (WIR) - A Contact Survey Experiment for Water and Carbonates on Mars; 29) Mid-IR Fiber Optic Probe for In Situ Water Detection and Characterization; 30) Effects of Subsurface Sampling & Processing on Martian Simulant Containing Varying Quantities of Water; 31) The Subsurface Ice Probe (SIPR): A Low-Power Thermal Probe for the Martian Polar Layered Deposits; 32) Deploying Ground Penetrating Radar in Planetary Analog Sites to Evaluate Potential Instrument Capabilities on Future Mars Missions; 33) Evaluation of Rock Powdering Methods to Obtain Fine-grained Samples for CHEMIN, a Combined XRD/XRF Instrument; 34) Novel Sample-handling Approach for XRD Analysis with Minimal Sample Preparation; 35) A New Celestial Navigation Method for Mars Landers; 36) Mars Mineral Spectroscopy Web Site: A Resource for Remote Planetary Spectroscopy.

  11. [Evaluation of professional knowledge and attitudes on dementia patient care: a trans-cultural adaptation of an evaluation instrument].

    PubMed

    Costa, Gislaine Desani da; Souza, Rosely Almeida; Yamashita, Cintia Hitomi; Pinheiro, Juliane Cibelle Ferreira; Alvarenga, Márcia Regina Martins; Oliveira, Maria Amélia de Campos

    2015-04-01

    To describe the trans-cultural adaptation of the evaluation instrument entitled Atenció Sanitària de Les Demències: la visió de L' Atenció Primarià from Catalan into versions in Portuguese for doctors and nurses. This study evaluates the knowledge and perspectives of these professionals in their treatment of patients diagnosed with dementia in cases of primary care. The adaptation followed internationally accepted rules, which include the following steps: translation, synthesis, back-translation, revision by a committee of specialists, and a test run with 35 practicing doctors and 35 practicing nurses in Brazil's Family Health Strategy (Estratégia Saúde da Família, or ESF in Portuguese). The translation, synthesis, and back-translation steps were performed satisfactorily; only small adjustments were required. The committee of specialists verified the face validity in the version translated into Portuguese, and all of the items that received an agreement score lower than 80% during the initial evaluation were revised. In the test run, the difficulties presented by the health care professionals did not reach 15% of the sample, and therefore, no changes were made. The Portuguese translation of the instrument can be considered semantically, idiomatically, culturally, and conceptually equivalent to the original Catalan version and is, therefore, appropriate for use in Brazil.

  12. Instrumentation of sampling aircraft for measurement of launch vehicle effluents

    NASA Technical Reports Server (NTRS)

    Wornom, D. E.; Woods, D. C.; Thomas, M. E.; Tyson, R. W.

    1977-01-01

    An aircraft was selected and instrumented to measure effluents emitted from large solid propellant rockets during launch activities. The considerations involved in aircraft selection, sampling probes, and instrumentation are discussed with respect to obtaining valid airborne measurements. Discussions of the data acquisition system used, the instrument power system, and operational sampling procedures are included. Representative measurements obtained from an actual rocket launch monitoring activity are also presented.

  13. Perme Intensive Care Unit Mobility Score and ICU Mobility Scale: translation into Portuguese and cross-cultural adaptation for use in Brazil

    PubMed Central

    Kawaguchi, Yurika Maria Fogaça; Nawa, Ricardo Kenji; Figueiredo, Thais Borgheti; Martins, Lourdes; Pires-Neto, Ruy Camargo

    2016-01-01

    ABSTRACT Objective: To translate the Perme Intensive Care Unit Mobility Score and the ICU Mobility Scale (IMS) into Portuguese, creating versions that are cross-culturally adapted for use in Brazil, and to determine the interobserver agreement and reliability for both versions. Methods: The processes of translation and cross-cultural validation consisted in the following: preparation, translation, reconciliation, synthesis, back-translation, review, approval, and pre-test. The Portuguese-language versions of both instruments were then used by two researchers to evaluate critically ill ICU patients. Weighted kappa statistics and Bland-Altman plots were used in order to verify interobserver agreement for the two instruments. In each of the domains of the instruments, interobserver reliability was evaluated with Cronbach's alpha coefficient. The correlation between the instruments was assessed by Spearman's correlation test. Results: The study sample comprised 103 patients-56 (54%) of whom were male-with a mean age of 52 ± 18 years. The main reason for ICU admission (in 44%) was respiratory failure. Both instruments showed excellent interobserver agreement (κ > 0.90) and reliability (α > 0.90) in all domains. Interobserver bias was low for the IMS and the Perme Score (−0.048 ± 0.350 and −0.06 ± 0.73, respectively). The 95% CIs for the same instruments ranged from −0.73 to 0.64 and −1.50 to 1.36, respectively. There was also a strong positive correlation between the two instruments (r = 0.941; p < 0.001). Conclusions: In their versions adapted for use in Brazil, both instruments showed high interobserver agreement and reliability. PMID:28117473

  14. In vitro evaluation of efficacy of different rotary instrument systems for gutta percha removal during root canal retreatment

    PubMed Central

    Joseph, Mercy; Malhotra, Amit; Rao, Murali; Sharma, Abhimanyu; Talwar, Sangeeta

    2016-01-01

    Background Complete removal of old filling material during root canal retreatment is fundamental for predictable cleaning and shaping of canal anatomy. Most of the retreatment methods tested in earlier studies have shown inability to achieve complete removal of root canal filling. Therefore the aim of this investigation was to assess the efficacy of three different rotary nickel titanium retreatment systems and Hedstrom files in removing filling material from root canals. Material and Methods Sixty extracted mandibular premolars were decoronated to leave 15 mm root. Specimen were hand instrumented and obturated using gutta percha and AH plus root canal sealer. After storage period of two weeks, roots were retreated with three (Protaper retreatment files, Mtwo retreatment files, NRT GPR) rotary retreatment instrument systems and Hedstroem files. Subsequently, samples were sectioned longitudinally and examined under stereomicroscope. Digital images were recorded and evaluated using Digital Image Analysing Software. The retreatment time was recorded for each tooth using a stopwatch. The area of canal and the residual filling material was recorded in mm2 and the percentage of remaining filling material on canal walls was calculated. Data was analysed using ANOVA test. Results Significantly less amount of residual filling material was present in protaper and Mtwo instrumented teeth (p < 0.05) compared to NRT GPR and Hedstrom files group. Protaper instruments also required lesser time during removal of filling material followed by Mtwo instruments, NRT GPR files and Hedstrom files. Conclusions None of the instruments were able to remove the filling material completely from root canal. Protaper universal retreatment system and Mtwo retreatment files were more efficient and faster compared to NRT GPR fles and Hedstrom files. Key words:Gutta-percha removal, nickel titanium, root canal retreatment, rotary instruments. PMID:27703601

  15. Cyclic fatigue analysis of twisted file rotary NiTi instruments used in reciprocating motion.

    PubMed

    Gambarini, G; Gergi, R; Naaman, A; Osta, N; Al Sudani, D

    2012-09-01

    To evaluate the cyclic fatigue fracture resistance of engine-driven twisted file (TF) instruments under reciprocating movement. A sample of 30 size 25, 0.08 taper NiTi TF instruments was tested in a simulated canal with 60˚ angle of curvature and a 3 mm radius. During mechanical testing, different movement kinematics were used at a constant speed, which resulted in three experimental groups (each group n = 10). The instruments from the first group (G1) were rotated until fracture occurred. The instruments in the second (G2) and third group (G3) were driven under reciprocating movement with different angles of reciprocation. The time of fracture for each instrument was measured, and statistical analysis was performed using one-way analysis of variance followed by Tukey's Honestly Significant Different test. Reciprocating movement resulted in a significantly longer cyclic fatigue life (P < 0.0001) when compared with continuous rotation. No difference was found between reciprocation 150° clockwise/30° counterclockwise (CW/CCW) and 30° CW/150° CCW. The reciprocating movement was associated with an extended cyclic fatigue life of the TF size 0.25, 0.08 taper instruments in comparison with conventional rotation. © 2012 International Endodontic Journal.

  16. Development of an advanced spacecraft tandem mass spectrometer

    NASA Astrophysics Data System (ADS)

    Drew, Russell C.

    1992-03-01

    The purpose of this research was to apply current advanced technology in electronics and materials to the development of a miniaturized Tandem Mass Spectrometer that would have the potential for future development into a package suitable for spacecraft use. The mass spectrometer to be used as a basis for the tandem instrument would be a magnetic sector instrument, of Nier-Johnson configuration, as used on the Viking Mars Lander mission. This instrument configuration would then be matched with a suitable second stage MS to provide the benefits of tandem MS operation for rapid identification of unknown organic compounds. This tandem instrument is configured with a newly designed GC system to aid in separation of complex mixtures prior to MS analysis. A number of important results were achieved in the course of this project. Among them were the development of a miniaturized GC subsystem, with a unique desorber-injector, fully temperature feedback controlled oven with powered cooling for rapid reset to ambient conditions, a unique combination inlet system to the MS that provides for both membrane sampling and direct capillary column sample transfer, a compact and ruggedized alignment configuration for the MS, an improved ion source design for increased sensitivity, and a simple, rugged tandem MS configuration that is particularly adaptable to spacecraft use because of its low power and low vacuum pumping requirements. The potential applications of this research include use in manned spacecraft like the space station as a real-time detection and warning device for the presence of potentially harmful trace contaminants of the spacecraft atmosphere, use as an analytical device for evaluating samples collected on the Moon or a planetary surface, or even use in connection with monitoring potentially hazardous conditions that may exist in terrestrial locations such as launch pads, environmental test chambers or other sensitive areas. Commercial development of the technology could lead to a new family of environmental test instruments that would be small and portable, yet would give quick analyses of complex samples.

  17. Development of an advanced spacecraft tandem mass spectrometer

    NASA Technical Reports Server (NTRS)

    Drew, Russell C.

    1992-01-01

    The purpose of this research was to apply current advanced technology in electronics and materials to the development of a miniaturized Tandem Mass Spectrometer that would have the potential for future development into a package suitable for spacecraft use. The mass spectrometer to be used as a basis for the tandem instrument would be a magnetic sector instrument, of Nier-Johnson configuration, as used on the Viking Mars Lander mission. This instrument configuration would then be matched with a suitable second stage MS to provide the benefits of tandem MS operation for rapid identification of unknown organic compounds. This tandem instrument is configured with a newly designed GC system to aid in separation of complex mixtures prior to MS analysis. A number of important results were achieved in the course of this project. Among them were the development of a miniaturized GC subsystem, with a unique desorber-injector, fully temperature feedback controlled oven with powered cooling for rapid reset to ambient conditions, a unique combination inlet system to the MS that provides for both membrane sampling and direct capillary column sample transfer, a compact and ruggedized alignment configuration for the MS, an improved ion source design for increased sensitivity, and a simple, rugged tandem MS configuration that is particularly adaptable to spacecraft use because of its low power and low vacuum pumping requirements. The potential applications of this research include use in manned spacecraft like the space station as a real-time detection and warning device for the presence of potentially harmful trace contaminants of the spacecraft atmosphere, use as an analytical device for evaluating samples collected on the Moon or a planetary surface, or even use in connection with monitoring potentially hazardous conditions that may exist in terrestrial locations such as launch pads, environmental test chambers or other sensitive areas. Commercial development of the technology could lead to a new family of environmental test instruments that would be small and portable, yet would give quick analyses of complex samples.

  18. Alternatives to SiOx for protective scan mirror coatings in remote sensing instruments

    NASA Astrophysics Data System (ADS)

    MacDonald, Michael E.

    1999-09-01

    Mirrors in remote sensing instruments require durable dielectric coatings, both to prevent oxidation of the reflective surface and to protect it during cleaning. IR absorption bands within widely-used SiOx coatings produce scene radiance and instrument background variations as a function of scan mirror angle which motivate the search for possible substitute materials. In this work several candidate coatings are evaluated including CeF3, HfO2, MgF2 SrF2, and Y2O3. This evaluation consists of reflectance, adhesion, and durability measurements of mirrors with an aluminum reflective surface over-coated with these materials. S-polarized and P- polarized reflectance measurements are presented between 2 and 20 micrometers for incidence angles between 40 and 50 degrees. This angular range is sufficient to scan the earth disk from geostationary orbit. Additional measurements at 45 degrees incidence are presented between 2 and 55 micrometers , covering the IR wavelength range of interest for earth radiation budget sensors. Comparisons are drawn with measurements of scan- mirror witness samples from the imaging and sounding instruments used in the Geostationary Operational Environmental Satellite (GOES). These witness samples exhibit reflectance variations arising from IR absorption bands in the SiOx protective coatings used in these mirrors. The spectral characteristics of several of the alternate materials are found to be quite attractive, however durable coatings of some of these materials require elevated deposition temperature which are incompatible with the nickel-coated beryllium scan mirror substrate construction used in GOES. This work present the achievable reflectance and durability of these alternate dielectric protective coatings at the deposition temperature constraints imposed by the scan mirror substrate. The prospects for substituting one of these coatings for SiOx are evaluated, and contrasted with the capability of radiometric calibration techniques to deal with the reflectance variations produced by SiOx coatings.

  19. Förster resonance energy transfer (FRET)-based picosecond lifetime reference for instrument response evaluation

    NASA Astrophysics Data System (ADS)

    Luchowski, R.; Kapusta, P.; Szabelski, M.; Sarkar, P.; Borejdo, J.; Gryczynski, Z.; Gryczynski, I.

    2009-09-01

    Förster resonance energy transfer (FRET) can be utilized to achieve ultrashort fluorescence responses in time-domain fluorometry. In a poly(vinyl) alcohol matrix, the presence of 60 mM Rhodamine 800 acceptor shortens the fluorescence lifetime of a pyridine 1 donor to about 20 ps. Such a fast fluorescence response is very similar to the instrument response function (IRF) obtained using scattered excitation light. A solid fluorescent sample (e.g a film) with picosecond lifetime is ideal for IRF measurements and particularly useful for time-resolved microscopy. Avalanche photodiode detectors, commonly used in this field, feature color- dependent-timing responses. We demonstrate that recording the fluorescence decay of the proposed FRET-based reference sample yields a better IRF approximation than the conventional light-scattering method and therefore avoids systematic errors in decay curve analysis.

  20. A simple automated instrument for DNA extraction in forensic casework.

    PubMed

    Montpetit, Shawn A; Fitch, Ian T; O'Donnell, Patrick T

    2005-05-01

    The Qiagen BioRobot EZ1 is a small, rapid, and reliable automated DNA extraction instrument capable of extracting DNA from up to six samples in as few as 20 min using magnetic bead technology. The San Diego Police Department Crime Laboratory has validated the BioRobot EZ1 for the DNA extraction of evidence and reference samples in forensic casework. The BioRobot EZ1 was evaluated for use on a variety of different evidence sample types including blood, saliva, and semen evidence. The performance of the BioRobot EZ1 with regard to DNA recovery and potential cross-contamination was also assessed. DNA yields obtained with the BioRobot EZ1 were comparable to those from organic extraction. The BioRobot EZ1 was effective at removing PCR inhibitors, which often co-purify with DNA in organic extractions. The incorporation of the BioRobot EZ1 into forensic casework has streamlined the DNA analysis process by reducing the need for labor-intensive phenol-chloroform extractions.

  1. Acquisition of a High Resolution Field Emission Scanning Electron Microscope for the Analysis of Returned Samples

    NASA Technical Reports Server (NTRS)

    Nittler, Larry R.

    2003-01-01

    This grant furnished funds to purchase a state-of-the-art scanning electron microscope (SEM) to support our analytical facilities for extraterrestrial samples. After evaluating several instruments, we purchased a JEOL 6500F thermal field emission SEM with the following analytical accessories: EDAX energy-dispersive x-ray analysis system with fully automated control of instrument and sample stage; EDAX LEXS wavelength-dispersive x-ray spectrometer for high sensitivity light-element analysis; EDAX/TSL electron backscatter diffraction (EBSD) system with software for phase identification and crystal orientation mapping; Robinson backscatter electron detector; and an in situ micro-manipulator (Kleindiek). The total price was $550,000 (with $150,000 of the purchase supported by Carnegie institution matching funds). The microscope was delivered in October 2002, and most of the analytical accessories were installed by January 2003. With the exception of the wavelength spectrometer (which has been undergoing design changes) everything is working well and the SEM is in routine use in our laboratory.

  2. Aerostat-lofted instrument and sampling method for determination of emissions from open area sources

    EPA Science Inventory

    An aerostat-borne instrument and sampling method was developed to characterize air samples from area sources, such as emissions from open burning. The 10 kg battery-powered instrument system, termed "the Flyer," is lofted with a helium-filled aerostat of 4 m nominal diameter and ...

  3. Rural Parents’ Perceived Stigma of Seeking Mental Health Services for their Children: Development and Evaluation of a New Instrument

    PubMed Central

    Williams, Stacey L.; Polaha, Jodi

    2014-01-01

    The purpose of this paper was to examine the validity of score interpretations of an instrument developed to measure parents’ perceptions of stigma about seeking mental health services for their children. The validity of the score interpretations of the instrument was tested in two studies. Study 1 examined confirmatory factor analysis (CFA) employing a split half approach, and construct and criterion validity using the entire sample of parents in rural Appalachia whose children were experiencing psychosocial concerns (N=347), while Study 2 further examined CFA, construct and criterion validity, as well as predictive validity of the scores on the new scale using a general sample of parents in rural Appalachia (N=184). Results of exploratory and confirmatory factor analyses revealed support for a two factor model of parents’ perceived stigma, which represented both self and public forms of stigma associated with seeking mental health services for their children, and correlated with existing measures of stigma and other psychosocial variables. Further, the new self and public stigma scale significantly predicted parents’ willingness to seek services for children. PMID:24749752

  4. Validation of the Osteoporosis Smoking Health Belief instrument.

    PubMed

    Doheny, Margaret O; Sedlak, Carol A; Zeller, Richard; Estok, Patricia J

    2010-01-01

    Smoking has a deleterious effect on bone mineral density. Psychometric properties were conducted for 3 smoking cessation subscales of the Osteoporosis Smoking Health Belief (OSHB) instrument: barriers, benefits, and self-efficacy. The instrument was evaluated by 6 nurse researchers, administered to a pilot sample of 23 adult smokers aged 19-39, and to a convenience sample of 59 adult smokers aged 19-84 years attending bingo at churches and community centers. Principal components factor analyses were conducted on the 18 items at both time points and accounted for 65.05% of the variances in the matrix at Time 1 and 71.19% at Time 2. The 3 statistical factors corresponded to the theoretically derived concepts. Cronbach's alphas for benefits of not smoking were .86 at Time 1 and .88 at Time 2; for barriers, .78 at Time 1 and .89 at Time 2; and for self-efficacy, .94 at Time 1 and .96 at Time 2. The test-retest correlations were .68 for benefits, .74 for barriers, and .79 for self-efficacy. Paired t tests showed no significant change over time. The OSHB meets relevant measurement criteria.

  5. Standard-less analysis of Zircaloy clad samples by an instrumental neutron activation method

    NASA Astrophysics Data System (ADS)

    Acharya, R.; Nair, A. G. C.; Reddy, A. V. R.; Goswami, A.

    2004-03-01

    A non-destructive method for analysis of irregular shape and size samples of Zircaloy has been developed using the recently standardized k0-based internal mono standard instrumental neutron activation analysis (INAA). The samples of Zircaloy-2 and -4 tubes, used as fuel cladding in Indian boiling water reactors (BWR) and pressurized heavy water reactors (PHWR), respectively, have been analyzed. Samples weighing in the range of a few tens of grams were irradiated in the thermal column of Apsara reactor to minimize neutron flux perturbations and high radiation dose. The method utilizes in situ relative detection efficiency using the γ-rays of selected activation products in the sample for overcoming γ-ray self-attenuation. Since the major and minor constituents (Zr, Sn, Fe, Cr and/or Ni) in these samples were amenable to NAA, the absolute concentrations of all the elements were determined using mass balance instead of using the concentration of the internal mono standard. Concentrations were also determined in a smaller size Zircaloy-4 sample by irradiating in the core position of the reactor to validate the present methodology. The results were compared with literature specifications and were found to be satisfactory. Values of sensitivities and detection limits have been evaluated for the elements analyzed.

  6. Developments in Sampling and Analysis Instrumentation for Stationary Sources

    ERIC Educational Resources Information Center

    Nader, John S.

    1973-01-01

    Instrumentation for the measurement of pollutant emissions is considered including sample-site selection, sample transport, sample treatment, sample analysis, and data reduction, display, and interpretation. Measurement approaches discussed involve sample extraction from within the stack and electro-optical methods. (BL)

  7. Nurses' assessments and patients' perceptions: development of the Night Nursing Care Instrument (NNCI), measuring nursing care at night.

    PubMed

    Johansson, Peter; Oléni, Magnus; Fridlund, Bengt

    2005-07-01

    Nursing care provided at night has a different purpose and objective to that provided during the day. A review of the literature does not reveal any scientifically tested research instruments for evaluating and comparing the nurse's assessment of nursing care with the patient's perception at night. The aim of this study was to develop and test an instrument for evaluating nursing care and to compare nurses' assessments with patients' perceptions of nursing care provided at night. The study was carried out in two phases; the first had an explorative design and the second an evaluative and comparative design. The Night Nursing Care Instrument (NNCI) included two questionnaires; one for nurses and one for patients. These questionnaires were developed from a nursing framework and covered the following three areas: 'nursing interventions', 'medical interventions' and 'evaluation'. Nurses (n = 40) on night duty on a medical ward at a central hospital in southern Sweden were consecutively selected, to participate in the study. The patients (n = 80) were selected by means of convenience sampling. In order to achieve construct validity, factor analysis of each individual area was carried out. Reliability in terms of internal consistency was tested by Cronbach's alpha. The overall NNCI had acceptable reliability and validity. There was no statistically significant difference between nurses' assessments and patients' perceptions in any of the three areas of 'nursing interventions', 'medical interventions' or 'evaluation'. The patients rated night nursing care as satisfactory for the majority of the items. These findings demonstrate that it is possible to create a short instrument with acceptable reliability and validity, which is easy to use in clinical practice. The results also show that night nurses need to improve their ability to assess patients' needs during the night to increase the quality of night nursing care.

  8. Transformation From a Conventional Clinical Microbiology Laboratory to Full Automation.

    PubMed

    Moreno-Camacho, José L; Calva-Espinosa, Diana Y; Leal-Leyva, Yoseli Y; Elizalde-Olivas, Dolores C; Campos-Romero, Abraham; Alcántar-Fernández, Jonathan

    2017-12-22

    To validate the performance, reproducibility, and reliability of BD automated instruments in order to establish a fully automated clinical microbiology laboratory. We used control strains and clinical samples to assess the accuracy, reproducibility, and reliability of the BD Kiestra WCA, the BD Phoenix, and BD Bruker MALDI-Biotyper instruments and compared them to previously established conventional methods. The following processes were evaluated: sample inoculation and spreading, colony counts, sorting of cultures, antibiotic susceptibility test, and microbial identification. The BD Kiestra recovered single colonies in less time than conventional methods (e.g. E. coli, 7h vs 10h, respectively) and agreement between both methodologies was excellent for colony counts (κ=0.824) and sorting cultures (κ=0.821). Antibiotic susceptibility tests performed with BD Phoenix and disk diffusion demonstrated 96.3% agreement with both methods. Finally, we compared microbial identification in BD Phoenix and Bruker MALDI-Biotyper and observed perfect agreement (κ=1) and identification at a species level for control strains. Together these instruments allow us to process clinical urine samples in 36h (effective time). The BD automated technologies have improved performance compared with conventional methods, and are suitable for its implementation in very busy microbiology laboratories. © American Society for Clinical Pathology 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  9. Recent developments in the analysis of toxic elements.

    PubMed

    Lisk, D J

    1974-06-14

    One may conclude that it is impractical to confine oneself to any one analytical method since ever more sensitive instrumentation continues to be produced. However, in certain methods such as anodic stripping voltammetry and flameless atomic absorption it may be background contamination from reagent impurities and surroundings rather than instrument sensitivity which controls the limits of element detection. The problem of contamination from dust or glassware is greatly magnified when the sample size becomes ever smaller. Air entering laboratories near highways may contain trace quantities of lead, cadmium, barium, antimony, and other elements from engine exhaust. Even plastic materials contacting the sample may be suspect as a source of contamination since specific metals may be used as catalysts in the synthesis of the plastic and traces may be retained in it. Certain elements may even be deliberately added to plastics during manufacture for identification purposes. Nondestructive methods such as neutron activation and x-ray techniques thus offer great advantages not only in time but in the elimination of impurities introduced during sample ashing. Future improvements in attainable limits of detection may arise largely from progress in the ultrapurification of reagents and "clean-room" techniques. Finally, the competence of the analyst is also vitally important in the skillful operation of modern complex analytical instrumentation and in the experienced evaluation of data.

  10. Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure with image analysis

    DOEpatents

    Van Berkel, Gary J.; Kertesz, Vilmos

    2011-08-09

    A system and method utilizes an image analysis approach for controlling the collection instrument-to-surface distance in a sampling system for use, for example, with mass spectrometric detection. Such an approach involves the capturing of an image of the collection instrument or the shadow thereof cast across the surface and the utilization of line average brightness (LAB) techniques to determine the actual distance between the collection instrument and the surface. The actual distance is subsequently compared to a target distance for re-optimization, as necessary, of the collection instrument-to-surface during an automated surface sampling operation.

  11. Competence evaluation processes for nursing students abroad: Findings from an international case study.

    PubMed

    Tommasini, Cristina; Dobrowolska, Beata; Zarzycka, Danuta; Bacatum, Claudia; Bruun, Anne Marie Gran; Korsath, Dag; Roel, Siv; Jansen, Mette Bro; Milling, Tine; Deschamps, Anne; Mantzoukas, Stefanos; Mantzouka, Christine; Palese, Alvisa

    2017-04-01

    Assessing clinical competence in nursing students abroad is a challenge, and requires both methods and instruments capable of capturing the multidimensional nature of the clinical competences acquired. The aim of the study was to compare the clinical competence assessment processes and instruments adopted for nursing students during their clinical placement abroad. A case study design was adopted in 2015. A purposeful sample of eight nursing programmes located in seven countries (Belgium, Denmark, Greece, Norway, Poland, Portugal and Italy) were approached. Tools as instruments for evaluating competences developed in clinical training by international nursing students, and written procedures aimed at guiding the evaluation process, were scrutinised through a content analysis method. All clinical competence evaluation procedures and instruments used in the nursing programmes involved were provided in English. A final evaluation of the competences was expected by all nursing programmes at the end of the clinical placement, while only four provided an intermediate evaluation. Great variability emerged in the tools, with between five and 88 items included. Through content analysis, 196 items emerged, classified into 12 different core competence categories, the majority were categorised as 'Technical skills' (=60), 'Self-learning and critical thinking' (=27) and 'Nursing care process' (=25) competences. Little emphasis was given in the tools to competences involving 'Self-adaptation', 'Inter-professional skills', 'Clinical documentation', 'Managing nursing care', 'Patient communication', and 'Theory and practice integration'. Institutions signing Bilateral Agreements should agree upon the competences expected from students during their clinical education abroad. The tools used in the process, as well as the role expected by the student, should also be agreed upon. Intercultural competences should be further addressed in the process of evaluation, in addition to adaptation to different settings. There is also a need to establish those competences achievable or not in the host country, aiming at increasing transparency in learning expectations and evaluation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. LabVIEW-based control software for para-hydrogen induced polarization instrumentation.

    PubMed

    Agraz, Jose; Grunfeld, Alexander; Li, Debiao; Cunningham, Karl; Willey, Cindy; Pozos, Robert; Wagner, Shawn

    2014-04-01

    The elucidation of cell metabolic mechanisms is the modern underpinning of the diagnosis, treatment, and in some cases the prevention of disease. Para-Hydrogen induced polarization (PHIP) enhances magnetic resonance imaging (MRI) signals over 10,000 fold, allowing for the MRI of cell metabolic mechanisms. This signal enhancement is the result of hyperpolarizing endogenous substances used as contrast agents during imaging. PHIP instrumentation hyperpolarizes Carbon-13 ((13)C) based substances using a process requiring control of a number of factors: chemical reaction timing, gas flow, monitoring of a static magnetic field (Bo), radio frequency (RF) irradiation timing, reaction temperature, and gas pressures. Current PHIP instruments manually control the hyperpolarization process resulting in the lack of the precise control of factors listed above, resulting in non-reproducible results. We discuss the design and implementation of a LabVIEW based computer program that automatically and precisely controls the delivery and manipulation of gases and samples, monitoring gas pressures, environmental temperature, and RF sample irradiation. We show that the automated control over the hyperpolarization process results in the hyperpolarization of hydroxyethylpropionate. The implementation of this software provides the fast prototyping of PHIP instrumentation for the evaluation of a myriad of (13)C based endogenous contrast agents used in molecular imaging.

  13. Quality of life in children with Prader Willi Syndrome: Parent and child reports.

    PubMed

    Wilson, Kathleen S; Wiersma, Lenny D; Rubin, Daniela A

    2016-10-01

    The purpose of this study was to evaluate the use of the Peds QL4.0 instrument to assess quality of life (QL) in children with Prader Willi Syndrome (PWS). This study also sought to compare differences in parent and child report as well as between children with PWS and without PWS. Parents and children with PWS (N=44) completed the PedsQL 4.0 instrument. A sub-sample of children completed the Peds QL 4.0 a second time to assess test-retest reliability. A comparison sample of children who were obese but without PWS (N=66) also completed the PedsQL 4.0. PedsQL 4.0 showed acceptable internal consistency for the child report (αs >0.72) and was acceptable for 4 out of the 6 scales for the parent report (αs >0.66). Test-retest reliability coefficients showed support for the reliability of the instrument (ICCs>0.64). Parents perceived lower QL than children with PWS. Children with PWS also showed lower QL than children without PWS. This study provides support for the use of the PedsQL 4.0 instrument in children with PWS. As observed in other populations, parents perceive a lower QL for their children with PWS than the children themselves. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Relation between consumers' perceptions of color and texture of dairy desserts and instrumental measurements using a generalized procrustes analysis.

    PubMed

    González-Tomás, L; Costell, E

    2006-12-01

    Consumers' perceptions of the color and texture of 8 commercial vanilla dairy desserts were studied and related to color and rheological measurements. First, the 8 desserts were evaluated by a group of consumers by means of the Free Choice Profile. For both color and texture, a 2-dimensional solution was chosen, with dimension 1 highly related to yellow color intensity in the case of color and to thickness in the case of texture. Second, mechanical spectra, flow behavior, and instrumental color were determined. All the samples showed a time-dependent and shear-thinning flow and a mechanical spectrum typical of a weak gel. Differences were found in the flow index, in the apparent viscosity at 10 s(-1), and in the values of the storage modulus, the loss modulus, the loss angle tangent, and the complex viscosity at 1 Hz, as well as in the color parameters. Finally, sensory and instrumental relationships were investigated by a generalized Procrustes analysis. For both color and texture, a 3-dimensional solution explained a high percentage of the total variance (>80%). In these particular samples, the instrumental color parameters provided more accurate information on consumers' color perceptions than was provided by the rheological parameters of consumers' perceptions of texture.

  15. LabVIEW-based control software for para-hydrogen induced polarization instrumentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agraz, Jose, E-mail: joseagraz@ucla.edu; Grunfeld, Alexander; Li, Debiao

    2014-04-15

    The elucidation of cell metabolic mechanisms is the modern underpinning of the diagnosis, treatment, and in some cases the prevention of disease. Para-Hydrogen induced polarization (PHIP) enhances magnetic resonance imaging (MRI) signals over 10 000 fold, allowing for the MRI of cell metabolic mechanisms. This signal enhancement is the result of hyperpolarizing endogenous substances used as contrast agents during imaging. PHIP instrumentation hyperpolarizes Carbon-13 ({sup 13}C) based substances using a process requiring control of a number of factors: chemical reaction timing, gas flow, monitoring of a static magnetic field (B{sub o}), radio frequency (RF) irradiation timing, reaction temperature, and gas pressures.more » Current PHIP instruments manually control the hyperpolarization process resulting in the lack of the precise control of factors listed above, resulting in non-reproducible results. We discuss the design and implementation of a LabVIEW based computer program that automatically and precisely controls the delivery and manipulation of gases and samples, monitoring gas pressures, environmental temperature, and RF sample irradiation. We show that the automated control over the hyperpolarization process results in the hyperpolarization of hydroxyethylpropionate. The implementation of this software provides the fast prototyping of PHIP instrumentation for the evaluation of a myriad of {sup 13}C based endogenous contrast agents used in molecular imaging.« less

  16. Fragmentation of Solid Materials Using Shock Tubes. Part 2: First Test Series in a Large Diameter Shock Tube

    DTIC Science & Technology

    2017-12-01

    description in Figure 9 below 2 Full or partial loss of test data due to instrumentation/triggering failures 3 Gages not included in these tests 4...Table 2. Sample properties. Test Description Dimensions Weight (lbs.) Strength (psi) Notes 17 Fully Tempered Glass Window 4-ft x 6-ft x...an estimate of prism strength for medium weight CMU. The reinforced concrete sample was a 5.5-in thick solid panel. To evaluate its strength

  17. Microsphere Composites of Nano-Al and Nanothermite: An Approach to Better Utilization of Nanomaterials

    DTIC Science & Technology

    2014-01-01

    2 μm to 16 μm. The combustion behavior is found to be very different from either nanoaluminum or micron aluminum and their corresponding thermite ... thermite mixture with the addition of nanoparticles of copper oxide. In a typical experiment, 180 mg of Al nanoparticles, and 540 mg CuO nanoparticles...combustion performance of thermite samples was evaluated by igniting 25.0 mg of thermite sample in the combustion cell, instrumented with a fast

  18. Integrated nonlinear optical imaging microscope for on-axis crystal detection and centering at a synchrotron beamline

    PubMed Central

    Madden, Jeremy T.; Toth, Scott J.; Dettmar, Christopher M.; Newman, Justin A.; Oglesbee, Robert A.; Hedderich, Hartmut G.; Everly, R. Michael; Becker, Michael; Ronau, Judith A.; Buchanan, Susan K.; Cherezov, Vadim; Morrow, Marie E.; Xu, Shenglan; Ferguson, Dale; Makarov, Oleg; Das, Chittaranjan; Fischetti, Robert; Simpson, Garth J.

    2013-01-01

    Nonlinear optical (NLO) instrumentation has been integrated with synchrotron X-ray diffraction (XRD) for combined single-platform analysis, initially targeting applications for automated crystal centering. Second-harmonic-generation microscopy and two-photon-excited ultraviolet fluorescence microscopy were evaluated for crystal detection and assessed by X-ray raster scanning. Two optical designs were constructed and characterized; one positioned downstream of the sample and one integrated into the upstream optical path of the diffractometer. Both instruments enabled protein crystal identification with integration times between 80 and 150 µs per pixel, representing a ∼103–104-fold reduction in the per-pixel exposure time relative to X-ray raster scanning. Quantitative centering and analysis of phenylalanine hydroxylase from Chromobacterium violaceum cPAH, Trichinella spiralis deubiquitinating enzyme TsUCH37, human κ-opioid receptor complex kOR-T4L produced in lipidic cubic phase (LCP), intimin prepared in LCP, and α-cellulose samples were performed by collecting multiple NLO images. The crystalline samples were characterized by single-crystal diffraction patterns, while α-cellulose was characterized by fiber diffraction. Good agreement was observed between the sample positions identified by NLO and XRD raster measurements for all samples studied. PMID:23765294

  19. Psychometric properties of the Chinese version of the attitudes towards cardiopulmonary resuscitation with defibrillation (ACPRD-C) among female hospital nurses in Taiwan.

    PubMed

    Lin, Hsing-Long; Lin, Mei-Hsiang; Ho, Chao-Chung; Fu, Chin-Hua; Koo, Malcolm

    2017-07-01

    Nurses are often the first responders to in-hospital cardiac emergencies. A positive attitude towards cardiopulmonary resuscitation with defibrillation may contribute to early cardiopulmonary resuscitation and rapid defibrillation, which are associated with enhanced long-term survival. The aim of this study was to translate and adapt the 31-item attitudes towards cardiopulmonary resuscitation with defibrillation and the national resuscitation guidelines (ACPRD) instrument into Chinese and to evaluate its psychometric properties in a sample of Taiwanese hospital nurses. The ACPRD instrument was translated into Chinese using professional translation services. Content validity index based on five experts to refine the translated instrument. The final instrument was applied to a sample of 290 female nurses, recruited from a regional hospital in southern Taiwan, to assess its internal consistency, factor structure, and discriminative validity. The Chinese ACPRD instrument showed good internal consistency (Cronbach's alpha=0.87). Seven factors emerged from the factor analysis. The instrument showed good discriminative validity and were able to differentiate the attitudes of nurses with more experience of defibrillation or cardiopulmonary resuscitation from those with less experience. Nurses working in emergency ward or intensive care unit also showed significantly higher overall scores compared to those working in other units. The Chinese ACPRD demonstrated adequate content validity, internal consistency, sensible factor structure, and good discriminative validity. Among Chinese-speaking nurses, it may be used as a tool for assessing the effectiveness of educational programs that aim to improve their confidence in performing cardiopulmonary resuscitation with defibrillation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. An Adaptation of the Original Fresno Test to Measure Evidence-Based Practice Competence in Pediatric Bedside Nurses.

    PubMed

    Laibhen-Parkes, Natasha; Kimble, Laura P; Melnyk, Bernadette Mazurek; Sudia, Tanya; Codone, Susan

    2018-06-01

    Instruments used to assess evidence-based practice (EBP) competence in nurses have been subjective, unreliable, or invalid. The Fresno test was identified as the only instrument to measure all the steps of EBP with supportive reliability and validity data. However, the items and psychometric properties of the original Fresno test are only relevant to measure EBP with medical residents. Therefore, the purpose of this paper is to describe the development of the adapted Fresno test for pediatric nurses, and provide preliminary validity and reliability data for its use with Bachelor of Science in Nursing-prepared pediatric bedside nurses. General adaptations were made to the original instrument's case studies, item content, wording, and format to meet the needs of a pediatric nursing sample. The scoring rubric was also modified to complement changes made to the instrument. Content and face validity, and intrarater reliability of the adapted Fresno test were assessed during a mixed-methods pilot study conducted from October to December 2013 with 29 Bachelor of Science in Nursing-prepared pediatric nurses. Validity data provided evidence for good content and face validity. Intrarater reliability estimates were high. The adapted Fresno test presented here appears to be a valid and reliable assessment of EBP competence in Bachelor of Science in Nursing-prepared pediatric nurses. However, further testing of this instrument is warranted using a larger sample of pediatric nurses in diverse settings. This instrument can be a starting point for evaluating the impact of EBP competence on patient outcomes. © 2018 Sigma Theta Tau International.

  1. Influence of curvature location along an artificial canal on cyclic fatigue of a rotary nickel-titanium endodontic instrument.

    PubMed

    Lopes, Hélio Pereira; Chiesa, Wanderson Miguel Maia; Correia, Norbi Rodrigues; de Souza Navegante, Núbia Carvalho; Elias, Carlos Nelson; Moreira, Edson Jorge Lima; Chiesa, Bianca Esther Cabral

    2011-06-01

    This study evaluated the effects of curvature location along an artificial canal on cyclic fatigue (CF) of an Mtwo rotary instrument, verifying the number of cycles to fatigue fracture (NCF) and morphologic characteristics of the fractured instruments. CF testing of instruments was performed in artificial canals with curvature radii of 10 mm and arc lengths of 11 mm. Mtwo rotary instruments size 40, 0.04 taper were used in 2 groups (n = 10): group A, curvature positioned on middle part; group B, apical curvature. All instruments were rotated until fracture. The number of cycles to failure was registered. Data were analyzed by independent sample t test. Fractured surfaces and the helical shafts of the instruments were analyzed by scanning electron microscopy. NCF for groups A and B had significant statistic differences (P < .05). The highest values were found in the group where the curvature was positioned on the apical part of the canal. No plastic deformation was observed on the helical shafts. The number of cycles to fracture of the Mtwo instruments increased when the arc was changed from the middle to the apical part of the canal. The morphologic characteristics of the fractured surfaces were of the ductile type. Copyright © 2011 Mosby, Inc. All rights reserved.

  2. Evaluation of a handheld point-of-care analyser for measurement of creatinine in cats.

    PubMed

    Reeve, Jenny; Warman, Sheena; Lewis, Daniel; Watson, Natalie; Papasouliotis, Kostas

    2017-02-01

    Objectives The aim of the study was to evaluate whether a handheld creatinine analyser (StatSensor Xpress; SSXp), available for human patients, can be used to measure creatinine reliably in cats. Methods Analytical performance was evaluated by determining within- and between-run coefficient of variation (CV, %), total error observed (TE obs , %) and sigma metrics. Fifty client-owned cats presenting for investigation of clinical disease had creatinine measured simultaneously, using SSXp (whole blood and plasma) and a reference instrument (Konelab, serum); 48 paired samples were included in the study. Creatinine correlation between methodologies (SSXp vs Konelab) and sample types (SSXp whole blood vs SSXp plasma ) was assessed by Spearman's correlation coefficient and agreement was determined using Bland-Altman difference plots. Each creatinine value was assigned an IRIS stage (1-4); correlation and agreement between Konelab and SSXp IRIS stages were evaluated. Results Within-run CV (4.23-8.85%), between-run CV (8.95-11.72%), TE obs (22.15-34.92%) and sigma metrics (⩽3) did not meet desired analytical requirements. Correlation between sample types was high (SSXp whole blood vs SSXp plasma ; r = 0.89), and between instruments was high (SSXp whole blood vs Konelab serum ; r = 0.85) to very high (SSXp plasma vs Konelab serum ; r = 0.91). Konelab and SSXp whole blood IRIS scores exhibited high correlation ( r = 0.76). Packed cell volume did not significantly affect SSXp determination of creatinine. Bland-Altman difference plots identified a positive bias for the SSXp (7.13 μmol/l SSXp whole blood ; 20.23 μmol/l SSXp plasma ) compared with the Konelab. Outliers (1/48 whole blood; 2/48 plasma) occurred exclusively at very high creatinine concentrations. The SSXp failed to identify 2/21 azotaemic cats. Conclusions and relevance Analytical performance of the SSXp in feline patients is not considered acceptable. The SSXp exhibited a high to very high correlation compared with the reference methodology but the two instruments cannot be used interchangeably. Improvements in the SSXp analytical performance are needed before its use can be recommended in feline clinical practice.

  3. Analytical techniques for steroid estrogens in water samples - A review.

    PubMed

    Fang, Ting Yien; Praveena, Sarva Mangala; deBurbure, Claire; Aris, Ahmad Zaharin; Ismail, Sharifah Norkhadijah Syed; Rasdi, Irniza

    2016-12-01

    In recent years, environmental concerns over ultra-trace levels of steroid estrogens concentrations in water samples have increased because of their adverse effects on human and animal life. Special attention to the analytical techniques used to quantify steroid estrogens in water samples is therefore increasingly important. The objective of this review was to present an overview of both instrumental and non-instrumental analytical techniques available for the determination of steroid estrogens in water samples, evidencing their respective potential advantages and limitations using the Need, Approach, Benefit, and Competition (NABC) approach. The analytical techniques highlighted in this review were instrumental and non-instrumental analytical techniques namely gas chromatography mass spectrometry (GC-MS), liquid chromatography mass spectrometry (LC-MS), enzyme-linked immuno sorbent assay (ELISA), radio immuno assay (RIA), yeast estrogen screen (YES) assay, and human breast cancer cell line proliferation (E-screen) assay. The complexity of water samples and their low estrogenic concentrations necessitates the use of highly sensitive instrumental analytical techniques (GC-MS and LC-MS) and non-instrumental analytical techniques (ELISA, RIA, YES assay and E-screen assay) to quantify steroid estrogens. Both instrumental and non-instrumental analytical techniques have their own advantages and limitations. However, the non-instrumental ELISA analytical techniques, thanks to its lower detection limit and simplicity, its rapidity and cost-effectiveness, currently appears to be the most reliable for determining steroid estrogens in water samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. The Child Adolescent Bullying Scale (CABS): Psychometric evaluation of a new measure.

    PubMed

    Strout, Tania D; Vessey, Judith A; DiFazio, Rachel L; Ludlow, Larry H

    2018-06-01

    While youth bullying is a significant public health problem, healthcare providers have been limited in their ability to identify bullied youths due to the lack of a reliable, and valid instrument appropriate for use in clinical settings. We conducted a multisite study to evaluate the psychometric properties of a new 22-item instrument for assessing youths' experiences of being bullied, the Child Adolescent Bullying Scale (CABS). The 20 items summed to produce the measure's score were evaluated here. Diagnostic performance was assessed through evaluation of sensitivity, specificity, predictive values, and area under receiver operating characteristic (AUROC) curve. A sample of 352 youths from diverse racial, ethnic, and geographic backgrounds (188 female, 159 male, 5 transgender, sample mean age 13.5 years) were recruited from two clinical sites. Participants completed the CABS and existing youth bullying measures. Analyses grounded in classical test theory, including assessments of reliability and validity, item analyses, and principal components analysis, were conducted. The diagnostic performance and test characteristics of the CABS were also evaluated. The CABS is comprised of one component, accounting for 67% of observed variance. Analyses established evidence of internal consistency reliability (Cronbach's α = 0.97), construct and convergent validity. Sensitivity was 84%, specificity was 65%, and the AUROC curve was 0.74 (95% CI: 0.69-0.80). Findings suggest that the CABS holds promise as a reliable, valid tool for healthcare provider use in screening for bullying exposure in the clinical setting. © 2018 Wiley Periodicals, Inc.

  5. Generation and analysis of chemical compound libraries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gregoire, John M.; Jin, Jian; Kan, Kevin S.

    2017-10-03

    Various samples are generated on a substrate. The samples each includes or consists of one or more analytes. In some instances, the samples are generated through the use of gels or through vapor deposition techniques. The samples are used in an instrument for screening large numbers of analytes by locating the samples between a working electrode and a counter electrode assembly. The instrument also includes one or more light sources for illuminating each of the samples. The instrument is configured to measure the photocurrent formed through a sample as a result of the illumination of the sample.

  6. Evaluation of trace elements in lung samples from coal miners using neutron activation analysis.

    PubMed

    Saiki, M; Saldiva, P H; Alice, S H

    1999-01-01

    In this study, instrumental neutron activation analysis was applied to the determination of Sc, La, Ce, Nd, Sm, Eu, Tb, Yb, Lu, Hf, Th, and U in lung samples from miners working in coal mines located in the state of Santa Catarina, Brazil. These results were compared to those from a control group constituted of healthy individuals. The results showed that the elements determined exhibit considerable intersubject variability within a single group of individuals and the mean values of concentrations in miners' lungs were higher than those of normal individuals. Lung samples presented U concentrations varying from 11 to 890 micrograms/kg. Therefore, for some samples, the contribution of the uranium fission products in the analysis of La, Ce, Nd, and Sm was considered by determining the interference correction factors. The accuracy of the results was evaluated by analyzing certified reference materials.

  7. Psychometric evaluation of the Revised Professional Practice Environment (RPPE) scale.

    PubMed

    Erickson, Jeanette Ives; Duffy, Mary E; Ditomassi, Marianne; Jones, Dorothy

    2009-05-01

    The purpose was to examine the psychometric properties of the Revised Professional Practice Environment (RPPE) scale. Despite renewed focus on studying health professionals' practice environments, there are still few reliable and valid instruments available to assist nurse administrators in decision making. A psychometric evaluation using a random-sample cross-validation procedure (calibration sample [CS], n = 775; validation sample [VS], n = 775) was undertaken. Cronbach alpha internal consistency reliability of the total score (r = 0.93 [CS] and 0.92 [VS]), resulting subscale scores (r range: 0.80-0.87 [CS], 0.81-0.88 [VS]), and principal components analyses with Varimax rotation and Kaiser normalization (8 components, 59.2% variance [CS], 59.7% [VS]) produced almost identical results in both samples. The multidimensional RPPE is a psychometrically sound measure of 8 components of the professional practice environment in the acute care setting and sufficiently reliable and valid for use as independent subscales in healthcare research.

  8. Content Analysis of Evaluation Instruments Used for Student Evaluation of Classroom Teaching Performance in Higher Education.

    ERIC Educational Resources Information Center

    Tagomori, Harry T.; Bishop, Laurence A.

    A major argument against evaluation of teacher performance by students pertains to the instruments being used. Colleges conduct instructional evaluation using instruments they devise, borrow, adopt, or adapt from other institutions. Whether these instruments are tested for content validity is unknown. This study determined how evaluation questions…

  9. A New Culture of Assessment: Preliminary Report on the ARL SERVQUAL Survey.

    ERIC Educational Resources Information Center

    Cook, Colleen; Heath, Fred; Thompson, Bruce

    Texas A&M University and the Association of Research Libraries (ARL) under the New Measures initiative are engaged in a project to evaluate service quality in research libraries using an augmented SERVQUAL instrument. In spring 2000, 13 ARL libraries in North America invited a random sample of students and faculty to take the survey through…

  10. Prevalence, Causes and Effects of Bullying in Tertiary Institutions in Cross River State, Nigeria

    ERIC Educational Resources Information Center

    Ada, Mary Juliana; Okoli, Georgina; Obeten, Okoi Okorn; Akeke, M. N. G.

    2016-01-01

    This research is an evaluation of the impact of causes, consequences and effects of bullying in academic setting on student academic performance in tertiary institutions in Cross River State, Nigeria. The research made use of purposive and random sampling techniques made up of 302 students. Questionnaire served as the data collection instrument.…

  11. 33 CFR 148.405 - What are the procedures for notifying the Commandant (CG-5) of proposed site evaluation and pre...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... proposed location and purpose of the activities, including: (1) Gravity and magneto-metric measurements; (2...) Sediment sampling of a limited nature using either core or grab samplers, and the specified diameter and...) Hydrographic and oceanographic measurements, including the setting of instruments; and (7) Small diameter core...

  12. 33 CFR 148.405 - What are the procedures for notifying the Commandant (CG-5) of proposed site evaluation and pre...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... proposed location and purpose of the activities, including: (1) Gravity and magneto-metric measurements; (2...) Sediment sampling of a limited nature using either core or grab samplers, and the specified diameter and...) Hydrographic and oceanographic measurements, including the setting of instruments; and (7) Small diameter core...

  13. An Examination of Factors Associated with School Psychologists' Provision of Counseling Services

    ERIC Educational Resources Information Center

    DeFago, Jennifer Kelly

    2012-01-01

    The purpose of this study was to evaluate the factors that predict provision of counseling services by Ohio-based school psychologists. In order to address the research questions, a survey instrument was created and a sample of school psychologists working in Ohio completed a questionnaire regarding their counseling practices. The data were…

  14. Psychometric Properties of the Disability Assessment Schedule (DAS) for Behavior Problems: An Independent Investigation

    ERIC Educational Resources Information Center

    Tsakanikos, Elias; Underwood, Lisa; Sturmey, Peter; Bouras, Nick; McCarthy, Jane

    2011-01-01

    The present study employed the Disability Assessment Schedule (DAS) to assess problem behaviors in a large sample of adults with ID (N = 568) and evaluate the psychometric properties of this instrument. Although the DAS problem behaviors were found to be internally consistent (Cronbach's [alpha] = 0.87), item analysis revealed one weak item…

  15. Educational Service Quality in Zanjan University of Medical Sciences from Students' Point of View

    ERIC Educational Resources Information Center

    Mohammadi, Ali; Mohammadi, Jamshid

    2014-01-01

    This study aims at evaluating perceived service quality in Zanjan University of Medical Sciences (ZUMS). This study was cross-sectional and authors surveyed educational services at ZUMS. Through stratified random sampling, 384 students were selected and an adapted SERVQUAL instrument was used for data collection. Data analysis was performed by…

  16. Science Plan U.S. Geological Survey Florida District

    DTIC Science & Technology

    2001-01-01

    coastline of the United States during a particularly active period of hurricane activity in 1998. endocrine disruptors , are beginning to receive...reconnaissance sampling for emergent contaminants (pharmaceuticals, pesticides, endocrine disruptor compounds) to develop additional projects. Figure 31...pathogens, and endocrine disruptor compounds. (Issue 4) • Evaluation of new instrumentation for specific applications in Florida, such as

  17. Structure of Perceptions of Service Quality in Libraries: A LibQUAL+ Study.

    ERIC Educational Resources Information Center

    Thompson, Bruce; Cook, Colleen; Heath, Fred

    2003-01-01

    Used confirmatory factor analysis to evaluate the score integrity of LibQUALl+, an instrument to measure perceptions of library service quality. Results for 60,027 graduate and undergraduate students suggest that the model implied by LibQUAL is reasonable and invariant across independent samples and fits all three major subgroups of library users.…

  18. Do Males and Females Conceptualise Work and Social Impairment Differently Following Treatment for Different Mental Health Problems?

    PubMed

    Smith, David; Fairweather-Schmidt, A Kate; Riley, Ben; Javidi, Zhila; Zabeen, Sara; Lawn, Sharon; Battersby, Malcolm

    2018-04-01

    The Work and Social Adjustment Scale (WSAS) is used by psychiatric nurses for screening and evaluating patients' treatment outcomes for a variety of mental health problems. This study investigated longitudinal and gender measurement invariance of WSAS using structural equation modeling within a help-seeking problem gambling sample (n=445), and an intervention program for depression and anxiety sample (n=444). The concept of functional impairment was defined by all WSAS items in males and females at pre- and post-treatment assessments. These findings confirm that the WSAS is a robust and efficacious instrument for evaluating treatment outcomes in two differing populations. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. The Validation of a Software Evaluation Instrument.

    ERIC Educational Resources Information Center

    Schmitt, Dorren Rafael

    This study, conducted at six southern universities, analyzed the validity and reliability of a researcher developed instrument designed to evaluate educational software in secondary mathematics. The instrument called the Instrument for Software Evaluation for Educators uses measurement scales, presents a summary section of the evaluation, and…

  20. Sensory and rapid instrumental methods as a combined tool for quality control of cooked ham.

    PubMed

    Barbieri, Sara; Soglia, Francesca; Palagano, Rosa; Tesini, Federica; Bendini, Alessandra; Petracci, Massimiliano; Cavani, Claudio; Gallina Toschi, Tullia

    2016-11-01

    In this preliminary investigation, different commercial categories of Italian cooked pork hams have been characterized using an integrated approach based on both sensory and fast instrumental measurements. For these purposes, Italian products belonging to different categories (cooked ham, "selected" cooked ham and "high quality" cooked ham) were evaluated by sensory descriptive analysis and by the application of rapid tools such as image analysis by an "electronic eye" and texture analyzer. The panel of trained assessors identified and evaluated 10 sensory descriptors able to define the quality of the products. Statistical analysis highlighted that sensory characteristics related to appearance and texture were the most significant in discriminating samples belonged to the highest (high quality cooked hams) and the lowest (cooked hams) quality of the product whereas the selected cooked hams, showed intermediate characteristics. In particular, high quality samples were characterized, above all, by the highest intensity of pink intensity, typical appearance and cohesiveness, and, at the same time, by the lowest intensity of juiciness; standard cooked ham samples showed the lowest intensity of all visual attributes and the highest value of juiciness, whereas the intermediate category (selected cooked ham) was not discriminated from the other. Also physical-rheological parameters measured by electronic eye and texture analyzer were effective in classifying samples. In particular, the PLS model built with data obtained from the electronic eye showed a satisfactory performance in terms of prediction of the pink intensity and presence of fat attributes evaluated during the sensory visual phase. This study can be considered a first application of this combined approach that could represent a suitable and fast method to verify if the meat product purchased by consumer match its description in terms of compliance with the claimed quality.

  1. Development process and initial validation of the Ethical Conflict in Nursing Questionnaire-Critical Care Version.

    PubMed

    Falcó-Pegueroles, Anna; Lluch-Canut, Teresa; Guàrdia-Olmos, Joan

    2013-06-01

    Ethical conflicts are arising as a result of the growing complexity of clinical care, coupled with technological advances. Most studies that have developed instruments for measuring ethical conflict base their measures on the variables 'frequency' and 'degree of conflict'. In our view, however, these variables are insufficient for explaining the root of ethical conflicts. Consequently, the present study formulates a conceptual model that also includes the variable 'exposure to conflict', as well as considering six 'types of ethical conflict'. An instrument was then designed to measure the ethical conflicts experienced by nurses who work with critical care patients. The paper describes the development process and validation of this instrument, the Ethical Conflict in Nursing Questionnaire Critical Care Version (ECNQ-CCV). The sample comprised 205 nursing professionals from the critical care units of two hospitals in Barcelona (Spain). The ECNQ-CCV presents 19 nursing scenarios with the potential to produce ethical conflict in the critical care setting. Exposure to ethical conflict was assessed by means of the Index of Exposure to Ethical Conflict (IEEC), a specific index developed to provide a reference value for each respondent by combining the intensity and frequency of occurrence of each scenario featured in the ECNQ-CCV. Following content validity, construct validity was assessed by means of Exploratory Factor Analysis (EFA), while Cronbach's alpha was used to evaluate the instrument's reliability. All analyses were performed using the statistical software PASW v19. Cronbach's alpha for the ECNQ-CCV as a whole was 0.882, which is higher than the values reported for certain other related instruments. The EFA suggested a unidimensional structure, with one component accounting for 33.41% of the explained variance. The ECNQ-CCV is shown to a valid and reliable instrument for use in critical care units. Its structure is such that the four variables on which our model of ethical conflict is based may be studied separately or in combination. The critical care nurses in this sample present moderate levels of exposure to ethical conflict. This study represents the first evaluation of the ECNQ-CCV.

  2. Carbon monoxide measurements over the eastern Pacific during GTE/CITE 1. [Chemical Instrumentation Test and Evaluation

    NASA Technical Reports Server (NTRS)

    Condon, Estelle P.; Danielsen, Edwin F.; Sachse, Glen W.; Hill, Gerald F.

    1987-01-01

    As part of the Global Tropospheric Experiment's Chemical Instrumentation Test and Evaluation (GTE/CITE 1) intercomparison, carbon monoxide (CO) measurements were made from the NASA CV-990 aircraft during the fall of 1983 and again in the spring of 1984. The experimental measurements for CO obtained during those flight series over the eastern and mid-Pacific are presented here. Data were acquired from 10 to 20 deg N latitude over the mid-Pacific and from 30 to 37 deg N latitude over the eastern Pacific off the coast of California. A seasonal variation of approximately 34 parts per billion by volume was measured over the altitudes and latitudes sampled, and a small latitudinal variation was also noted. The data are discussed in terms of the meteorological context in which they were collected.

  3. Using the Patient Reported Outcomes Measurement Information System to Evaluate Psychosocial Functioning among Children with Craniofacial Anomalies.

    PubMed

    Shapiro, Danielle N; Waljee, Jennifer; Ranganathan, Kavitha; Buchman, Steven; Warschausky, Seth

    2015-06-01

    Children with craniofacial anomalies are at risk for social exclusion, bullying, and psychological symptoms, all of which are associated with poor developmental and health outcomes. The National Institutes of Health-developed Patient Reported Outcomes Measurement Information System instruments may be useful tools for monitoring psychosocial functioning in clinical settings and for integrating patient and parent perspectives. The current study included 74 children (50 percent male) with craniofacial anomalies recruited through a multidisciplinary clinic. The authors obtained child self-report and parent-proxy ratings of depression, anxiety, and peer relationship quality using National Institutes of Health Patient Reported Outcomes Measurement Information System instruments. The authors compared sample means to Patient Reported Outcomes Measurement Information System instruments norms and analyzed the reliability of parents' and children's reporting of psychosocial variables. All reliability statistics were satisfactory (α values ranging from 0.74 to 0.96) and sample standard deviations were similar to those obtained in a general population, suggesting that Patient Reported Outcomes Measurement Information System instruments are reliable among children with craniofacial anomalies. In general, children and parents did not report unusual levels of psychological distress; however, they did report poorer peer relationship quality relative to normed data, a trend that was particularly pronounced among boys. National Institutes of Health Patient Reported Outcomes Measurement Information System instruments are efficient and accurate tools for monitoring psychosocial adjustment among children with craniofacial anomalies. It may be especially important to monitor social functioning, particularly among boys.

  4. Evaluation of Three Field-Based Methods for Quantifying Soil Carbon

    PubMed Central

    Izaurralde, Roberto C.; Rice, Charles W.; Wielopolski, Lucian; Ebinger, Michael H.; Reeves, James B.; Thomson, Allison M.; Francis, Barry; Mitra, Sudeep; Rappaport, Aaron G.; Etchevers, Jorge D.; Sayre, Kenneth D.; Govaerts, Bram; McCarty, Gregory W.

    2013-01-01

    Three advanced technologies to measure soil carbon (C) density (g C m−2) are deployed in the field and the results compared against those obtained by the dry combustion (DC) method. The advanced methods are: a) Laser Induced Breakdown Spectroscopy (LIBS), b) Diffuse Reflectance Fourier Transform Infrared Spectroscopy (DRIFTS), and c) Inelastic Neutron Scattering (INS). The measurements and soil samples were acquired at Beltsville, MD, USA and at Centro International para el Mejoramiento del Maíz y el Trigo (CIMMYT) at El Batán, Mexico. At Beltsville, soil samples were extracted at three depth intervals (0–5, 5–15, and 15–30 cm) and processed for analysis in the field with the LIBS and DRIFTS instruments. The INS instrument determined soil C density to a depth of 30 cm via scanning and stationary measurements. Subsequently, soil core samples were analyzed in the laboratory for soil bulk density (kg m−3), C concentration (g kg−1) by DC, and results reported as soil C density (kg m−2). Results from each technique were derived independently and contributed to a blind test against results from the reference (DC) method. A similar procedure was employed at CIMMYT in Mexico employing but only with the LIBS and DRIFTS instruments. Following conversion to common units, we found that the LIBS, DRIFTS, and INS results can be compared directly with those obtained by the DC method. The first two methods and the standard DC require soil sampling and need soil bulk density information to convert soil C concentrations to soil C densities while the INS method does not require soil sampling. We conclude that, in comparison with the DC method, the three instruments (a) showed acceptable performances although further work is needed to improve calibration techniques and (b) demonstrated their portability and their capacity to perform under field conditions. PMID:23383225

  5. Apical extrusion of intracanal bacteria following use of two engine-driven instrumentation techniques.

    PubMed

    Er, K; Sümer, Z; Akpinar, K E

    2005-12-01

    To evaluate the number of bacteria extruded apically from extracted teeth ex vivo after canal instrumentation using the two engine-driven techniques utilizing nickel-titanium instruments (ProTaper and System GT). Forty extracted single-rooted human mandibular premolar teeth were used. Access cavities were prepared and root canals were then contaminated with a suspension of Enterococcus faecalis and dried. The contaminated roots were divided into two experimental groups of 15 teeth each and one control group of 10 teeth. Group 1, ProTaper group: the root canals were instrumented using ProTaper instruments. Group 2, System GT group: the root canals were instrumented using System GT instruments. Group 3, control group: no instrumentation was attempted. Bacteria extruded from the apical foramen during instrumentation were collected into vials. The microbiological samples from the vials were incubated in culture media for 24 h. Colonies of bacteria were counted and the results were given as number of colony-forming units. The data obtained were analysed using the Kruskal-Wallis one-way analysis of variance and Mann-Whitney U-tests, with alpha = 0.05 as the level for statistical significance. There was no significant difference as to the number of extruded bacteria between the ProTaper and System GT engine-driven systems (P > 0.05). Both engine-driven nickel-titanium systems extruded bacteria through the apical foramen.

  6. Development and psychometric evaluation of the Military Suicide Attitudes Questionnaire (MSAQ).

    PubMed

    VanSickle, Marcus; Tucker, Jennifer; Daruwala, Samantha; Ghahramanlou-Holloway, Marjan

    2016-10-01

    To date, a culturally-sensitive psychological instrument has not been developed to evaluate military attitudes toward suicide. Understanding these attitudes can inform suicide prevention research, clinical practice, and policy. We aimed to develop such an instrument and to evaluate its psychometric properties using an active-duty military sample. A team of military personnel, suicidologists, and researchers assisted with item development. A cross-sectional design was used to evaluate the psychometric properties of the Military Suicide Attitudes Questionnaire (MSAQ) via an online survey battery. Exploratory and confirmatory factor analyses were conducted. A total of 317 military service members met eligibility criteria and completed the online surveys. A four-factor model that explained 46.4% of the variance was identified: (1) Individual-Based Rejection versus Acceptance; (2) Psychache versus Pathological; (3) Unit-Based Rejection versus Acceptance; (4) Moral versus Immoral. The MSAQ demonstrated high partial validity and test-retest reliability. The study used a convenience sample and did not control for social desirability. The newly developed MSAQ is a promising measure that fills a notable gap in the assessment of suicide attitudes within the United States military. The MSAQ has the potential for future use in evaluating suicide prevention and stigma reduction programs within the Department of Defense. Additionally, the MSAQ may serve as a useful tool for leadership in the evaluation of command climates. In clinical settings, the MSAQ could be used along with other cognitive and attitudinal measures to track suicidal patients' attitude towards suicide over the course of treatment. Published by Elsevier B.V.

  7. Lifting SAM Instrument for Installation into Mars Rover

    NASA Image and Video Library

    2011-01-18

    NASA Sample Analysis at Mars SAM instrument, largest of the 10 science instruments for NASA Mars Science Laboratory mission, will examine samples of Martian rocks, soil and atmosphere for information about chemicals that are important to life.

  8. Development and validation of the Hospitality Axiological Scale for Humanization of Nursing Care

    PubMed Central

    Galán González-Serna, José María; Ferreras-Mencia, Soledad; Arribas-Marín, Juan Manuel

    2017-01-01

    ABSTRACT Objective: to develop and validate a scale to evaluate nursing attitudes in relation to hospitality for the humanization of nursing care. Participants: the sample consisted of 499 nursing professionals and undergraduate students of the final two years of the Bachelor of Science in Nursing program. Method: the instrument has been developed and validated to evaluate the ethical values related to hospitality using a methodological approach. Subsequently, a model was developed to measure the dimensions forming the construct hospitality. Results: the Axiological Hospitality Scale showed a high internal consistency, with Cronbach’s Alpha=0.901. The validation of the measuring instrument was performed using factorial, exploratory and confirmatory analysis techniques with high goodness of fit measures. Conclusions: the developed instrument showed an adequate validity and a high internal consistency. Based on the consistency of its psychometric properties, it is possible to affirm that the scale provides a reliable measurement of the hospitality. It was also possible to determine the dimensions or sources that embrace it: respect, responsibility, quality and transpersonal care. PMID:28793127

  9. Scanning magnetic tunnel junction microscope for high-resolution imaging of remanent magnetization fields

    NASA Astrophysics Data System (ADS)

    Lima, E. A.; Bruno, A. C.; Carvalho, H. R.; Weiss, B. P.

    2014-10-01

    Scanning magnetic microscopy is a new methodology for mapping magnetic fields with high spatial resolution and field sensitivity. An important goal has been to develop high-performance instruments that do not require cryogenic technology due to its high cost, complexity, and limitation on sensor-to-sample distance. Here we report the development of a low-cost scanning magnetic microscope based on commercial room-temperature magnetic tunnel junction (MTJ) sensors that typically achieves spatial resolution better than 7 µm. By comparing different bias and detection schemes, optimal performance was obtained when biasing the MTJ sensor with a modulated current at 1.0 kHz in a Wheatstone bridge configuration while using a lock-in amplifier in conjunction with a low-noise custom-made preamplifier. A precision horizontal (x-y) scanning stage comprising two coupled nanopositioners controls the position of the sample and a linear actuator adjusts the sensor-to-sample distance. We obtained magnetic field sensitivities better than 150 nT/Hz1/2 between 0.1 and 10 Hz, which is a critical frequency range for scanning magnetic microscopy. This corresponds to a magnetic moment sensitivity of 10-14 A m2, a factor of 100 better than achievable with typical commercial superconducting moment magnetometers. It also represents an improvement in sensitivity by a factor between 10 and 30 compared to similar scanning MTJ microscopes based on conventional bias-detection schemes. To demonstrate the capabilities of the instrument, two polished thin sections of representative geological samples were scanned along with a synthetic sample containing magnetic microparticles. The instrument is usable for a diversity of applications that require mapping of samples at room temperature to preserve magnetic properties or viability, including paleomagnetism and rock magnetism, nondestructive evaluation of materials, and biological assays.

  10. Integrated flexible handheld probe for imaging and evaluation of iridocorneal angle

    NASA Astrophysics Data System (ADS)

    Shinoj, Vengalathunadakal K.; Murukeshan, Vadakke Matham; Baskaran, Mani; Aung, Tin

    2015-01-01

    An imaging probe is designed and developed by integrating a miniaturized charge-coupled diode camera and light-emitting diode light source, which enables evaluation of the iridocorneal region inside the eye. The efficiency of the prototype probe instrument is illustrated initially by using not only eye models, but also samples such as pig eye. The proposed methodology and developed scheme are expected to find potential application in iridocorneal angle documentation, glaucoma diagnosis, and follow-up management procedures.

  11. An intercomparison of aircraft instrumentation for tropospheric measurements of sulfur dioxide

    NASA Technical Reports Server (NTRS)

    Gregory, Gerald L.; Davis, Douglas D.; Beltz, Nobert; Bandy, Alan R.; Ferek, Ronald J.; Thornton, Donald C.

    1993-01-01

    As part of the NASA Tropospheric Chemistry Program, a series of field intercomparisons have been conducted to evaluate the state-of-the art for measuring key tropospheric species. One of the objectives of the third intercomparison campaign in this series, Chemical Instrumentation Test and Evaluation 3 (CITE 3), was to evaluate instrumentation for making reliable tropospheric aircraft measurements of sulfur dioxide, dimethyl sulfide, hydrogen sulfide, carbon disulfide, and carbonyl sulfide. This paper reports the results of the intercomparisons of five sulfur dioxide measurement methods ranging from filter techniques, in which samples collected in flight are returned to the laboratory for analyses (chemiluminescent or ion chromatographic), to near real-time, in-flight measurements via gas chromatographic, mass spectrometric, and chemiluminescent techniques. All techniques showed some tendency to track sizeable changes in ambient SO2 such as those associated with altitude changes. For SO2 mixing ratios in the range of 200 pptv to a few ppbv, agreement among the techniques varies from about 30% to several orders of magnitude, depending upon the pair of measurements intercompared. For SO2 mixing ratios less than 200 pptv, measurements from the techniques are uncorrelated. In general, observed differences in the measurement of standards do not account for the flight results. The CITE 3 results do not unambiguously identify one or more of the measurement techniques as providing valid or invalid SO2 measurements, but identify the range of 'potential' uncertainty in SO2 measurements reported by currently available instrumentation and as measured under realistic aircraft environments.

  12. Evaluation of the Q analyzer, a new cap-piercing fully automated coagulometer with clotting, chromogenic, and immunoturbidometric capability.

    PubMed

    Kitchen, Steve; Woolley, Anita

    2013-01-01

    The Q analyzer is a recently launched fully automated photo-optical analyzer equipped with primary tube cap-piercing and capable of clotting, chromogenic, and immunoturbidometric tests. The purpose of the present study was to evaluate the performance characteristics of the Q analyzer with reagents from the instrument manufacturer. We assessed precision and throughput when performing coagulation screening tests, prothrombin time (PT)/international normalized ratio (INR), activated partial thromboplastin time (APTT), and fibrinogen assay by Clauss assay. We compared results with established reagent instrument combinations in widespread use. Precision of PT/INR and APTT was acceptable as indicated by total precision of around 3%. The time to first result was 3  min for an INR and 5  min for PT/APTT. The system produced 115 completed samples per hour when processing only INRs and 60 samples (120 results) per hour for PT/APTT combined. The sensitivity of the DG-APTT Synth/Q method to mild deficiency of factor VIII (FVIII), IX, and XI was excellent (as indicated by APTTs being prolonged above the upper limit of the reference range). The Q analyzer was associated with high precision, acceptable throughput, and good reliability. When used in combination with DG-PT reagent and manufacturer's instrument-specific international sensitivity index, the INRs obtained were accurate. The Q analyzer with DG-APTT Synth reagent demonstrated good sensitivity to isolated mild deficiency of FVIII, IX, and XI and had the advantage of relative insensitivity to mild FXII deficiency. Taken together, our data indicate that the Q hemostasis analyzer was suitable for routine use in combination with the reagents evaluated.

  13. The Nursing Performance Instrument: Exploratory and Confirmatory Factor Analyses in Registered Nurses.

    PubMed

    Sagherian, Knar; Steege, Linsey M; Geiger-Brown, Jeanne; Harrington, Donna

    2018-04-01

    The optimal performance of nurses in healthcare settings plays a critical role in care quality and patient safety. Despite this importance, few measures are provided in the literature that evaluate nursing performance as an independent construct from competencies. The nine-item Nursing Performance Instrument (NPI) was developed to fill this gap. The aim of this study was to examine and confirm the underlying factor structure of the NPI in registered nurses. The design was cross-sectional, using secondary data collected between February 2008 and April 2009 for the "Fatigue in Nursing Survey" (N = 797). The sample was predominantly dayshift female nurses working in acute care settings. Using Mplus software, exploratory and confirmatory factor analyses were applied to the NPI data, which were divided into two equal subsamples. Multiple fit indices were used to evaluate the fit of the alternative models. The three-factor model was determined to fit the data adequately. The factors that were labeled as "physical/mental decrements," "consistent practice," and "behavioral change" were moderately to strongly intercorrelated, indicating good convergent validity. The reliability coefficients for the subscales were acceptable. The NPI consists of three latent constructs. This instrument has the potentialto be used as a self-monitoring instrument that addressesnurses' perceptions of performance while providing patient care.

  14. Sensory and instrumental analysis for slipperiness and compliance of food during swallowing.

    PubMed

    Seo, H-S; Hwang, I K; Han, T R; Kim, I S

    2007-11-01

    In spite of its importance, there have been few attempts to evaluate the sensory attributes of the food bolus during swallowing. In the current study, the slipperiness, the degree of slide for the food bolus through the mucosal surface of the oro-pharynx, and the compliance, how easily the shape of a food bolus can be transformed for automatic and comfortable swallowing, were derived among several sensory attributes related to the swallowing. Therefore, the study aims were twofold: (1) to develop the methods of sensory and instrumental analyses for determining the slipperiness and compliance of the food bolus during swallowing and (2) to examine the appropriateness of the newly designed devices by correlating the data between the sensory and instrumental analyses. Six commercial food products were evaluated by 10 trained panelists for each attribute. The devices for assessing each attribute were developed in consideration of the oro-pharyngeal movements. The sensory and instrumental analyses showed high correlation and regression coefficients as well as intensity differences of the 6 samples for each attribute. In conclusion, the slipperiness and the compliance were suitable for acquiring a better understanding of the sensory attributes of the food bolus during swallowing, and the newly developed devices showed a high potential for determining those attributes.

  15. Principles of survey development for telemedicine applications.

    PubMed

    Demiris, George

    2006-01-01

    Surveys can be used in the evaluation of telemedicine applications but they must be properly designed, consistent and accurate. The purpose of the survey and the resources available will determine the extent of testing that a survey instrument should undergo prior to its use. The validity of an instrument is the correspondence between what is being measured and what was intended to be measured. The reliability of an instrument describes the 'consistency' or 'repeatability' of the measurements made with it. Survey instruments should be designed and tested following basic principles of survey development. The actual survey administration also requires consideration, for example data collection and processing, as well as the interpretation of the findings. Surveys are of two different types. Either they are self-administered, or they are administered by interview. In the latter case, they may be administered by telephone or in a face-to-face meeting. It is important to design a survey instrument based on a detailed definition of what it intends to measure and to test it before administering it to the larger sample.

  16. Evaluation of beam tracking strategies for the THOR-CSW solar wind instrument

    NASA Astrophysics Data System (ADS)

    De Keyser, Johan; Lavraud, Benoit; Prech, Lubomir; Neefs, Eddy; Berkenbosch, Sophie; Beeckman, Bram; Maggiolo, Romain; Fedorov, Andrei; Baruah, Rituparna; Wong, King-Wah; Amoros, Carine; Mathon, Romain; Génot, Vincent

    2017-04-01

    We compare different beam tracking strategies for the Cold Solar Wind (CSW) plasma spectrometer on the ESA M4 THOR mission candidate. The goal is to intelligently select the energy and angular windows the instrument is sampling and to adapt these windows as the solar wind properties evolve, with the aim to maximize the velocity distribution acquisition rate while maintaining excellent energy and angular resolution. Using synthetic data constructed using high-cadence measurements by the Faraday cup instrument on the Spektr-R mission (30 ms resolution), we test the performance of energy beam tracking with or without angular beam tracking. The algorithm can be fed both by data acquired by the plasma spectrometer during the previous measurement cycle, or by data from another instrument, in casu the Faraday Cup (FAR) instrument foreseen on THOR. We verify how these beam tracking algorithms behave for different sizes of the energy and angular windows, and for different data integration times, in order to assess the limitations of the algorithm and to avoid situations in which the algorithm loses track of the beam.

  17. Psychometric Properties of the Theory of Mind Assessment Scale in a Sample of Adolescents and Adults.

    PubMed

    Bosco, Francesca M; Gabbatore, Ilaria; Tirassa, Maurizio; Testa, Silvia

    2016-01-01

    This research aimed at the evaluation of the psychometric properties of the Theory of Mind Assessment Scale (Th.o.m.a.s.). Th.o.m.a.s. is a semi-structured interview meant to evaluate a person's Theory of Mind (ToM). It is composed of several questions organized in four scales, each focusing on one of the areas of knowledge in which such faculty may manifest itself: Scale A (I-Me) investigates first-order first-person ToM; Scale B (Other-Self) investigates third-person ToM from an allocentric perspective; Scale C (I-Other) again investigates third-person ToM, but from an egocentric perspective; and Scale D (Other-Me) investigates second-order ToM. The psychometric proprieties of Th.o.m.a.s. were evaluated in a sample of 156 healthy persons: 80 preadolescent and adolescent (aged 11-17 years, 42 females) and 76 adults (aged from 20 to 67 years, 35 females). Th.o.m.a.s. scores show good inter-rater agreement and internal consistency; the scores increase with age. Evidence of criterion validity was found as Scale B scores were correlated with those of an independent instrument for the evaluation of ToM, the Strange Stories task. Confirmatory factor analysis (CFA) showed good fit of the four-factors theoretical model to the data, although the four factors were highly correlated. For each of the four scales, Rasch analyses showed that, with few exceptions, items fitted the Partial credit model and their functioning was invariant for gender and age. The results of this study, along with those of previous researches with clinical samples, show that Th.o.m.a.s. is a promising instrument to assess ToM in different populations.

  18. Psychometric Properties of the Theory of Mind Assessment Scale in a Sample of Adolescents and Adults

    PubMed Central

    Bosco, Francesca M.; Gabbatore, Ilaria; Tirassa, Maurizio; Testa, Silvia

    2016-01-01

    This research aimed at the evaluation of the psychometric properties of the Theory of Mind Assessment Scale (Th.o.m.a.s.). Th.o.m.a.s. is a semi-structured interview meant to evaluate a person's Theory of Mind (ToM). It is composed of several questions organized in four scales, each focusing on one of the areas of knowledge in which such faculty may manifest itself: Scale A (I-Me) investigates first-order first-person ToM; Scale B (Other-Self) investigates third-person ToM from an allocentric perspective; Scale C (I-Other) again investigates third-person ToM, but from an egocentric perspective; and Scale D (Other-Me) investigates second-order ToM. The psychometric proprieties of Th.o.m.a.s. were evaluated in a sample of 156 healthy persons: 80 preadolescent and adolescent (aged 11–17 years, 42 females) and 76 adults (aged from 20 to 67 years, 35 females). Th.o.m.a.s. scores show good inter-rater agreement and internal consistency; the scores increase with age. Evidence of criterion validity was found as Scale B scores were correlated with those of an independent instrument for the evaluation of ToM, the Strange Stories task. Confirmatory factor analysis (CFA) showed good fit of the four-factors theoretical model to the data, although the four factors were highly correlated. For each of the four scales, Rasch analyses showed that, with few exceptions, items fitted the Partial credit model and their functioning was invariant for gender and age. The results of this study, along with those of previous researches with clinical samples, show that Th.o.m.a.s. is a promising instrument to assess ToM in different populations. PMID:27242563

  19. Monolithic Integration of Two-Dimensional Liquid Chromatography-Capillary Electrophoresis and Electrospray Ionization on a Microfluidic Device

    PubMed Central

    Chambers, Andrew G.; Mellors, J. Scott; Henley, W. Hampton; Ramsey, J. Michael

    2011-01-01

    A microfluidic device capable of two-dimensional reversed-phase liquid chromatography-capillary electrophoresis with integrated electrospray ionization (LC-CE-ESI) for mass spectrometry (MS)-based proteomic applications is described. Traditional instrumentation was used for the LC sample injection and delivery of the LC mobile phase. The glass microfabricated device incorporated a sample-trapping region and an LC channel packed with reversed-phase particles. Rapid electrokinetic injections of the LC effluent into the CE dimension were performed at a cross channel intersection. The CE separation channel terminated at a corner of the square device, which functioned as an integrated electrospray tip. In addition to LC-CE-ESI, this device was used for LC-ESI without any instrumental modifications. To evaluate the system, LC-MS and LC-CE-MS analysis of protein digests were performed and compared. PMID:21214194

  20. An instrument to assess subjective task value beliefs regarding the decision to pursue postgraduate training.

    PubMed

    Hagemeier, Nicholas E; Murawski, Matthew M

    2014-02-12

    To develop and validate an instrument to assess subjective ratings of the perceived value of various postgraduate training paths followed using expectancy-value as a theoretical framework; and to explore differences in value beliefs across type of postgraduate training pursued and type of pharmacy training completed prior to postgraduate training. A survey instrument was developed to sample 4 theoretical domains of subjective task value: intrinsic value, attainment value, utility value, and perceived cost. Retrospective self-report methodology was employed to examine respondents' (N=1,148) subjective task value beliefs specific to their highest level of postgraduate training completed. Exploratory and confirmatory factor analytic techniques were used to evaluate and validate value belief constructs. Intrinsic, attainment, utility, cost, and financial value constructs resulted from exploratory factor analysis. Cross-validation resulted in a 26-item instrument that demonstrated good model fit. Differences in value beliefs were noted across type of postgraduate training pursued and pharmacy training characteristics. The Postgraduate Training Value Instrument demonstrated evidence of reliability and construct validity. The survey instrument can be used to assess value beliefs regarding multiple postgraduate training options in pharmacy and potentially inform targeted recruiting of individuals to those paths best matching their own value beliefs.

  1. Toward the characterization of biological toxins using field-based FT-IR spectroscopic instrumentation

    NASA Astrophysics Data System (ADS)

    Schiering, David W.; Walton, Robert B.; Brown, Christopher W.; Norman, Mark L.; Brewer, Joseph; Scott, James

    2004-12-01

    IR spectroscopy is a broadly applicable technique for the identification of covalent materials. Recent advances in instrumentation have made Fourier Transform infrared (FT-IR) spectroscopy available for field characterization of suspect materials. Presently, this instrumentation is broadly deployed and used for the identification of potential chemical hazards. This discussion concerns work towards expanding the analytical utility of field-based FT-IR spectrometry in the characterization of biological threats. Two classes of materials were studied: biologically produced chemical toxins which were non-peptide in nature and peptide toxin. The IR spectroscopic identification of aflatoxin-B1, trichothecene T2 mycotoxin, and strychnine was evaluated using the approach of spectral searching against large libraries of materials. For pure components, the IR method discriminated the above toxins at better than the 99% confidence level. The ability to identify non-peptide toxins in mixtures was also evaluated using a "spectral stripping" search approach. For the mixtures evaluated, this method was able to identify the mixture components from ca. 32K spectral library entries. Castor bean extract containing ricin was used as a representative peptide toxin. Due to similarity in protein spectra, a SIMCA pattern recognition methodology was evaluated for classifying peptide toxins. In addition to castor bean extract the method was validated using bovine serum albumin and myoglobin as simulants. The SIMCA approach was successful in correctly classifying these samples at the 95% confidence level.

  2. The new materials science diffractometer STRESS-SPEC at FRM-II

    NASA Astrophysics Data System (ADS)

    Hofmann, M.; Schneider, R.; Seidl, G. A.; Rebelo-Kornmeier, J.; Wimpory, R. C.; Garbe, U.; Brokmeier, H.-G.

    2006-11-01

    In response to the development of new materials and the application of materials and components in new technologies the direct measurement, calculation and evaluation of textures and residual stresses has gained worldwide significance in recent years. In order to cater for the development of these analytical techniques the Materials Science Diffractometer STRESS-SPEC at FRM-II is designed to be equally applied to texture or residual stress analysis by virtue of its flexible configuration and the high neutron flux at the sample position. The instrument is now available for routine operation and here we present details of first experiments and instrument performance.

  3. Academic dishonesty among nursing students: a descriptive study.

    PubMed

    Keçeci, Ayla; Bulduk, Serap; Oruç, Deniz; Çelik, Serpil

    2011-09-01

    This descriptive and cross-sectional study aims to evaluate academic dishonesty among university nursing students in Turkey. The study's sample included 196 students. Two instruments were used for gathering data. The first instrument, a questionnaire, which included some socio-demographic variables (age, class, gender, education, family structure, parents' attitude and educators' attitude) formed the first part. The second part included the Academic Dishonesty Tendency Scale developed by Eminoğlu and Nartgün. The data were analyzed using descriptive statistics and Kruskall Wallis, One-way Anova, t- test and Mann-Whitney U test. It was found that academic dishonesty was at medium-level (2.60-3.39) in nursing students.

  4. Strategies and Technologies for In Situ Mineralogical Investigations on Mars

    NASA Technical Reports Server (NTRS)

    Marshall, J. R.; Bratton, C.; Koppel, L.; Hecht, M.; Metzger, E.

    1999-01-01

    Surface landers on Mars (Viking and Pathfinder) have not revealed satisfying answers to the mineralogy and lithology of the planet's surface. In part, this results from their prime directives: Viking focused on exobiology, Pathfinder focused on technology demonstration. The analytical instruments on board the landers made admirable attempts to extract the mineralogy and geology of Mars, as did countless modeling efforts after the missions. Here we suggest a framework for elucidating martian, or any other planetary geology, through an approach that defines (a) type of information required, (b) explorational strategy harmonious with acquisition of these data, (c) interpretation approach to the data, (d) compatible mission architecture, (e) instrumentation for interrogating rocks and soil. (a) Data required: The composition of a planet is ordered at scales ranging from molecules to minerals to rocks, and from geological units to provinces to planetary-scale systems. The largest ordering that in situ compositional instruments can attempt to interrogate is rock type "aggregate" information. This is what the geologist attempts to identify first. From this, mineralogy can be either directly seen or inferred. From mineralogy can be determined elemental abundances and perhaps the state of the compounds as being crystalline or amorphous. Knowledge of rock type and mineralogy is critical for elucidating geologic process. Mars landers acquired extremely valuable elemental data, but attempted to move from elements to aggregates, but this can only be done by making many assumptions and sometimes giant leaps of faith. Data we believe essential are elements, minerals, degree of ordering of compounds, and the aggregate or rock type that these materials compose. (b) Explorational strategy: A lander should function as a surrogate geologist. Of the total landscape, a geologist sees much, but gives detailed attention to an infinitesimally small amount of what is seen. To acquire samples worth detailed scrutiny, as many samples as possible need examining at a cursory or reconnaissance level. A representative, statistically-meaningful sample number cannot be overemphasized. This maxim still applies to geological exploration of our own planet of which we have abundant knowledge. Analysis of many samples mandates low-power consumption per sample. (c) Data interpretation: No single instrument can analyze the full spectrum of the x-axis. An instrument is optimized for detecting certain material characteristics and must therefore affix itself to some point on the x-axis. Any conclusions drawn about data to the left or right of the instrument's position on this axis must necessarily be derived by inference. Hence, it seems logical to include on a mission, instruments that are not closely spaced in their x-axis-position, and if only two analytical methods are used, as shown, they should start at opposite ends of the axis and work towards the center. As examples, we depict a high-resolution camera to evaluate rock type ("aggregate" state) and mineralogy, and an x-ray diffractometer-fluorescence spectrometer (XRD-XRF) to determine elements, minerals, and the degree of order of materials. (d) Mission architecture: No instrument or suite of instruments can be relied upon to always give truly unequivocal analyses. The suite of instruments should therefore permit conclusions of one instrument to be checked against those of another through closed analytical loops. These "loops" can be structured by a combination of orbital imagery, descent imagery, broad-band site viewing/analysis, and data that cover both x and y axes. For example, the detection of a basaltic-looking rock with a microscope should be checked against the elements detected, the appearance of the rock as a lava flow from descent imagery, and so forth. (e) Instrumentation: To satisfy the above criteria, it is necessary to: (i) See the rock or soil with high resolution + magnification, (ii) Examine many samples, (iii) Consume little power per analysis, (iv) Determine elemental species, (v) Determine mineralogy directly (not inferentially) and the degree of ordering of compounds, (vi) Start analyzing from both ends of the x-axis. Every geologist wants to see the hand sample first, and apply a hand lens to its surface. This has not been the starting point for missions to Mars. Thus, our technology satisfies all these criteria . This XRD-XRF-Optical instrument currently being developed, analyses rock or soil surfaces without the need for sample acquisition or preparation; this satisfies the power criterion, and enables many analyses. The device acquires direct mineralogy and determines elemental species. The embedded endoscopic camera satisfies the critical criterion of close inspection of samples; the fiber optic cable can also be used for IR, LTV, or laser sample analysis. Additional information is contained in the original (Figures).

  5. Appraising the quality of medical education research methods: the Medical Education Research Study Quality Instrument and the Newcastle-Ottawa Scale-Education.

    PubMed

    Cook, David A; Reed, Darcy A

    2015-08-01

    The Medical Education Research Study Quality Instrument (MERSQI) and the Newcastle-Ottawa Scale-Education (NOS-E) were developed to appraise methodological quality in medical education research. The study objective was to evaluate the interrater reliability, normative scores, and between-instrument correlation for these two instruments. In 2014, the authors searched PubMed and Google for articles using the MERSQI or NOS-E. They obtained or extracted data for interrater reliability-using the intraclass correlation coefficient (ICC)-and normative scores. They calculated between-scale correlation using Spearman rho. Each instrument contains items concerning sampling, controlling for confounders, and integrity of outcomes. Interrater reliability for overall scores ranged from 0.68 to 0.95. Interrater reliability was "substantial" or better (ICC > 0.60) for nearly all domain-specific items on both instruments. Most instances of low interrater reliability were associated with restriction of range, and raw agreement was usually good. Across 26 studies evaluating published research, the median overall MERSQI score was 11.3 (range 8.9-15.1, of possible 18). Across six studies, the median overall NOS-E score was 3.22 (range 2.08-3.82, of possible 6). Overall MERSQI and NOS-E scores correlated reasonably well (rho 0.49-0.72). The MERSQI and NOS-E are useful, reliable, complementary tools for appraising methodological quality of medical education research. Interpretation and use of their scores should focus on item-specific codes rather than overall scores. Normative scores should be used for relative rather than absolute judgments because different research questions require different study designs.

  6. Evaluation of conventional, protaper hand and protaper rotary instrumentation system for apical extrusion of debris, irrigants and bacteria- An in vitro randomized trial.

    PubMed

    Kalra, Pinky; Rao, Arathi; Suman, Ethel; Shenoy, Ramya; Suprabha, Baranya-Shrikrishna

    2017-02-01

    Endodontic instrumentation carries the risk of over extrusion of debris and bacteria. The technique used and the type of instrumentation influences this risk. The purpose of this study was to evaluate and compare the K-file, ProTaper hand and ProTaper rotary instrumentation systems for the amount of apically extruded debris, irrigant solution and intracanal bacteria. Experimental single blinded randomized type of in vitro study with sample of 30 single rooted teeth. Endodontic access cavities were prepared and the root canals were filled with the suspension of E. faecalis . Myers and Montogomery Model was used to collect apically extruded debris and irrigant. Canals were prepared using K files, Hand protapers and Protaper rotary files. Non Parametric test like Kruskal-Wallis and Mann-Whitney U test were applied to determine the significant differences among the group. Tests revealed statistically significant difference between the amount of debris and number of bacteria extruded by the ProTaper hand and the K-files. No statistically significant difference was observed between the amounts of irrigant extruded by the ProTaper hand and the K-file system. Statistically significant differences were observed between the amounts of bacteria and irrigant extruded by the ProTaper rotary and the Protaper hand. No statistically significant difference was observed between the amounts of debris extruded by the ProTaper hand and the K-file system. Amount of apical extrusion of irrigant solution, bacteria and debris are significantly greater with K File instruments and least with Protaper rotary instruments. Key words: Protaper, rotary, periapical extrusion.

  7. Psychometric properties of an instrument to measure nursing students' quality of life.

    PubMed

    Chu, Yanxiang; Xu, Min; Li, Xiuyun

    2015-07-01

    It is important for clinical nursing teachers and managers to recognize the importance of nursing students' quality of life (QOL) since they are the source of future nurses. As yet, there is no quality of life evaluation scale (QOLES) specific to them. This study designed a quantitative instrument for evaluating QOL of nursing students. The study design was a descriptive survey with mixed methods including literature review, panel discussion, Delphi method, and statistical analysis. The data were collected from 880 nursing students from four teaching hospitals in Wuhan, China. The reliability and validity of the scale were tested through completion of the QOLES in a cluster sampling method. The total scale included 18 items in three domains: physical, psychological, and social functional. The cumulative contributing rate of the three common factors was 65.23%. Cronbach's alpha coefficient of the scale was 0.82. This scale had good reliability and validity to evaluate nursing students' QOL. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Clinical antibacterial effectiveness of the self-adjusting file system.

    PubMed

    Neves, M A S; Rôças, I N; Siqueira, J F

    2014-04-01

    To evaluate in vivo the antibacterial effectiveness of the self-adjusting file (SAF) using molecular methods. Root canals from single-rooted teeth with apical periodontitis were instrumented using the SAF system under continuous irrigation with 2.5% NaOCl. DNA extracts from samples taken before and after instrumentation were subjected to quantitative analysis of total bacteria counts and levels of streptococci by quantitative real-time polymerase chain reaction (qPCR). The reverse-capture checkerboard assay was also used to identify 28 bacterial taxa before (S1) and after (S2) SAF instrumentation. SAF was also compared with a conventional hand nickel-titanium instrumentation technique for total bacterial reduction. Data from qPCR were analysed statistically within groups using the Wilcoxon matched pairs test and between groups using the Mann-Whitney U-test and the Fisher's exact test, with significance level set at P < 0.05. Self-adjusting file significantly reduced the total bacterial counts from a mean number of 1.96 × 10(7) cells to 1.34 × 10(4) cells (P < 0.001). Quantitatively, the 99.9% reduction in total bacterial counts associated with the SAF system was significantly superior to the 95.1% reduction obtained by hand instrumentation (P < 0.001). Qualitatively, SAF resulted in significantly more cases with negative PCR results for bacteria (54.5%) than hand instrumentation (4.5%) (P < 0.001). The SAF system succeeded in significantly reducing the streptococcal levels, but four cases still harboured these bacteria in S2. Checkerboard analysis revealed that not only streptococci but also some anaerobic and even as-yet-uncultivated bacteria may resist the effects of chemomechanical procedures. The SAF instrumentation system was highly effective in reducing bacterial populations from infected root canals and performed significantly better than hand instrumentation. However, because half of the samples still had detectable bacteria after preparation with SAF, supplementary disinfection is still required to maximize bacterial elimination. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  9. A portable x-ray fluorescence instrument for analyzing dust wipe samples for lead: evaluation with field samples.

    PubMed

    Sterling, D A; Lewis, R D; Luke, D A; Shadel, B N

    2000-06-01

    Dust wipe samples collected in the field were tested by nondestructive X-ray fluorescence (XRF) followed by laboratory analysis with flame atomic absorption spectrophotometry (FAAS). Data were analyzed for precision and accuracy of measurement. Replicate samples with the XRF show high precision with an intraclass correlation coefficient (ICC) of 0.97 (P<0.0001) and an overall coefficient of variation of 11.6%. Paired comparison indicates no statistical difference (P=0.272) between XRF and FAAS analysis. Paired samples are highly correlated with an R(2) ranging between 0.89 for samples that contain paint chips and 0.93 for samples that do not contain paint chips. The ICC for absolute agreement between XRF and laboratory results was 0.95 (P<0.0001). The relative error over the concentration range of 25 to 14,200 microgram Pb is -12% (95% CI, -18 to -5). The XRF appears to be an excellent method for rapid on-site evaluation of dust wipes for clearance and risk assessment purposes, although there are indications of some confounding when paint chips are present. Copyright 2000 Academic Press.

  10. The Social Anxiety and Depression Life Interference—24 Inventory: Classical and modern psychometric evaluations

    PubMed Central

    Berzins, Tiffany L.; Garcia, Antonio F.; Acosta, Melina; Osman, Augustine

    2017-01-01

    Two instrument validation studies broadened the research literature exploring the factor structure, internal consistency reliability, and concurrent validity of scores on the Social Anxiety and Depression Life Interference—24 Inventory (SADLI-24; Osman, Bagge, Freedenthal, Guiterrez, & Emmerich, 2011). Study 1 (N = 1065) was undertaken to concurrently appraise three competing factor models for the instrument: a unidimensional model, a two-factor oblique model and a bifactor model. The bifactor model provided the best fit to the study sample data. Study 2 (N = 220) extended the results from Study 1 with an investigation of the convergent and discriminant validity for the bifactor model of the SADLI-24 with multiple regression analyses and scale-level exploratory structural equation modeling. This project yields data that augments the initial instrument development investigations for the target measure. PMID:28781401

  11. Final Report on Jobin Yvon Contained Inductively Coupled Plasma Emission Spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pennebaker, F.M.

    2003-03-17

    A new Inductively Coupled Plasma -- Emission Spectrometer (ICP-ES) was recently purchased and installed in Lab B-147/151 at SRTC. The contained JY Model Ultima 170-C ICP-ES has been tested and compared to current ADS ICP-ES instrumentation. The testing has included both performance tests to evaluate instrumental ability, and the measurement of matrix standards commonly analyzed by ICP-ES at Savannah River. In developing operating procedures for this instrument, we have implemented the use of internal standards and off-peak background subtraction. Both of these techniques are recommended by EPA SW-846 ICP-ES methods and are common to current ICP-ES operations. Based on themore » testing and changes, the JY Model Ultima 170-C ICP-ES provides improved performance for elemental analysis of radioactive samples in the Analytical Development Section.« less

  12. DEMONSTRATION AND QUALITY ASSURANCE PROJECT ...

    EPA Pesticide Factsheets

    A demonstration of field portable/mobile technologies for measuring trace elements in soil and sediments was conducted under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation (SITE) Program. The demonstration took place from January 24 to 28, 2005, at the Kennedy Athletic, Recreational and Social Park at Kennedy Space Center on Merritt Island, Florida. The purpose of the demonstration was to verify the performance of various instruments that employ X-ray fluorescence (XRF) measurement technologies for the determination of 13 toxic elements in a variety of soil and sediment samples. Instruments from the technology developers listed below were demonstrated. o Innov-X Systems, Inc.o NITON LLC (2 instruments ) o Oxford Instruments Portable Division (formerly Metorex, Inc.) .Oxford Instruments Analytical .Rigaku, Inc.o RONTEC USA Inc.o Xcalibur XRF Services Inc. (Division of Elvatech Ltd. ) This demonstration plan describes the procedures that will be used to verify the performance and cost of the XRF instruments provided by these technology developers. The plan incorporates the quality assurance and quality control elements needed to generate data of sufficient quality to perform this verification. A separate innovative technology verification report (ITVR) will be prepared for each instrument. The objective of this program is to promote the acceptance and use of innovative field technologies by providing well-documented perfor

  13. Cultural differences in functional status measurement: analyses of person fit according to the Rasch model.

    PubMed

    Custers, J W; Hoijtink, H; van der Net, J; Helders, P J

    2000-01-01

    For many reasons it is preferable to use established health related outcome instruments. The validity of an instrument, however, can be affected when used in another culture or language other than what it was originally developed. In this paper, the outcome on functional status measurement using a preliminary version of the Dutch translated 'Pediatric Evaluation of Disability Inventory' (PEDI) was studied involving a sample of 20 non-disabled Dutch children and American peers, to see if a cross-cultural validation procedure is needed before using the instrument in the Netherlands. The Rasch model was used to analyse the Dutch data. Score profiles were not found to be compatible with the score profiles of American children. In particular, ten items were scored differently with strong indications that these were based on inter-cultural differences. Based on our study, it is argued that cross-cultural validation of the PEDI is necessary before using the instrument in the Netherlands.

  14. Analytic Method for Computing Instrument Pointing Jitter

    NASA Technical Reports Server (NTRS)

    Bayard, David

    2003-01-01

    A new method of calculating the root-mean-square (rms) pointing jitter of a scientific instrument (e.g., a camera, radar antenna, or telescope) is introduced based on a state-space concept. In comparison with the prior method of calculating the rms pointing jitter, the present method involves significantly less computation. The rms pointing jitter of an instrument (the square root of the jitter variance shown in the figure) is an important physical quantity which impacts the design of the instrument, its actuators, controls, sensory components, and sensor- output-sampling circuitry. Using the Sirlin, San Martin, and Lucke definition of pointing jitter, the prior method of computing the rms pointing jitter involves a frequency-domain integral of a rational polynomial multiplied by a transcendental weighting function, necessitating the use of numerical-integration techniques. In practice, numerical integration complicates the problem of calculating the rms pointing error. In contrast, the state-space method provides exact analytic expressions that can be evaluated without numerical integration.

  15. Increase in Periodontal Interleukin-1β Gene Expression Following Osseous Resective Surgery Using Conventional Rotary Instruments Compared with Piezosurgery: A Split-Mouth Randomized Clinical Trial.

    PubMed

    Aimetti, Mario; Ferrarotti, Francesco; Bergandi, Loredana; Saksing, Laura; Parducci, Francesca; Romano, Federica

    2016-01-01

    The purpose of this study was to evaluate the early inflammatory response following osseous resective surgery (ORS) with Piezosurgery compared to commonly used diamond burs. A sample was selected of 24 bilateral posterior sextants requiring ORS in 12 chronic periodontitis patients in a split-mouth design. In 12 sextants, bone recontouring was performed using a piezoelectric device. In the contralateral sextants, rotary instruments were used. Sextants treated with Piezosurgery obtained similar 12-month clinical results but lower postsurgical gene expression of interleukin-1β (IL-1β), a well-known proinflammatory cytokine, and lower patient morbidity compared with sextants treated with rotary instruments. In spite of the longer surgical time, the use of Piezosurgery for ORS seems to promote more favorable wound healing compared with rotary instruments, as the lower pain and the low levels of IL-1β mRNA at the surgical sites suggest a milder underlying inflammatory response.

  16. Evaluation of Harvard Lyman-α Hygrometer and Harvard Herriott Hygrometer measurements from the SEAC4RS flight campaign and AquaVIT2 laboratory comparison

    NASA Astrophysics Data System (ADS)

    Sargent, M. R.; Smith, J. B.; Wilmouth, D. M.; Sayres, D. S.; Anderson, J. G.

    2013-12-01

    Water vapor in the upper troposphere and lower stratosphere is central to both atmospheric chemistry and climate. Stratospheric water vapor concentrations influence surface dosages of UV radiation through the production of OH and by controlling the rates of heterogeneous reactions, both of which contribute to the catalytic destruction of ozone [e.g., Anderson et al., 2012]. Water vapor also impacts the radiative properties of the upper troposphere and lower stratosphere (UT/LS) directly and via the formation of thin cirrus, with the ability to significantly alter surface warming [Solomon et al., 2010]. However, with the documented disagreement among water vapor measurements on the order of 1 to 2 ppmv in the UT/LS, the atmospheric chemistry and climate community cannot reliably model the chemical and radiative properties of this region, predict the response of this region to anthropogenic climate forcing, or confidently detect trends in water vapor concentrations, particularly at the level of ~1%/year. In response to these concerns, the Harvard Water Vapor (HWV) instrument, designed for in situ measurement aboard NASA's high-altitude WB-57 and ER-2 aircraft, has been reconfigured to include two independent measurement methods for the simultaneous detection of ambient water vapor mixing ratios within a common duct. The dual-axis instrument combines the heritage of the Harvard Lyman-α photo-fragment fluorescence instrument (Ly-α) with the newly designed tunable diode laser direct absorption instrument, the Harvard Herriott Hygrometer (HHH). The utilization of two radically different measurement techniques facilitates the identification, diagnosis, and constraint of systematic errors in both the laboratory and flight environments. Here we present comparison data from two recent field campaigns which offered unprecedented opportunities for comparison and the assessment of instrumental accuracy in both the laboratory and in situ environments, 1) The Aqua Validation and Instrument Tests (AquaVIT-2), during April 2013 at the Aerosols Interaction and Dynamics in the Atmosphere (AIDA) chamber in Karlsruhe, Germany, and 2) NASA's Studies of Emissions, Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys (SEAC4RS) mission, operated out of Houston, TX, in August and September of 2013. The Aquavit-2 campaign provided an excellent opportunity to evaluate both axes of the HWV instrument under a controlled laboratory setting, and to compare with other state-of-the-art hygrometers within the international community, many of which have contributed substantially to UT/LS water vapor measurements for several decades. Laboratory efforts, however, are limited by their ability to replicate the unique sampling conditions, e.g., temperature, pressure, flow, chemistry, of the flight environment. Differences in instrument implementation between the laboratory and flight environment must also be considered. The SEAC4RS mission provides an excellent opportunity to further evaluate the performance of the dual-axis instrument in situ. Sampling with the Ly-α and HHH instruments on the ER-2 in the proximity of Microwave Limb Sounder (MLS) overpasses and coordinated launches of the Cryogenic Frostpoint Hygrometer (CFH) promises a statistically significant and rich dataset for comparison.

  17. Moving your laboratories to the field--Advantages and limitations of the use of field portable instruments in environmental sample analysis.

    PubMed

    Gałuszka, Agnieszka; Migaszewski, Zdzisław M; Namieśnik, Jacek

    2015-07-01

    The recent rapid progress in technology of field portable instruments has increased their applications in environmental sample analysis. These instruments offer a possibility of cost-effective, non-destructive, real-time, direct, on-site measurements of a wide range of both inorganic and organic analytes in gaseous, liquid and solid samples. Some of them do not require the use of reagents and do not produce any analytical waste. All these features contribute to the greenness of field portable techniques. Several stationary analytical instruments have their portable versions. The most popular ones include: gas chromatographs with different detectors (mass spectrometer (MS), flame ionization detector, photoionization detector), ultraviolet-visible and near-infrared spectrophotometers, X-ray fluorescence spectrometers, ion mobility spectrometers, electronic noses and electronic tongues. The use of portable instruments in environmental sample analysis gives a possibility of on-site screening and a subsequent selection of samples for routine laboratory analyses. They are also very useful in situations that require an emergency response and for process monitoring applications. However, quantification of results is still problematic in many cases. The other disadvantages include: higher detection limits and lower sensitivity than these obtained in laboratory conditions, a strong influence of environmental factors on the instrument performance and a high possibility of sample contamination in the field. This paper reviews recent applications of field portable instruments in environmental sample analysis and discusses their analytical capabilities. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. [The uncertainty evaluation of analytical results of 27 elements in geological samples by X-ray fluorescence spectrometry].

    PubMed

    Wang, Yi-Ya; Zhan, Xiu-Chun

    2014-04-01

    Evaluating uncertainty of analytical results with 165 geological samples by polarized dispersive X-ray fluorescence spectrometry (P-EDXRF) has been reported according to the internationally accepted guidelines. One hundred sixty five pressed pellets of similar matrix geological samples with reliable values were analyzed by P-EDXRF. These samples were divided into several different concentration sections in the concentration ranges of every component. The relative uncertainties caused by precision and accuracy of 27 components were evaluated respectively. For one element in one concentration, the relative uncertainty caused by precision can be calculated according to the average value of relative standard deviation with different concentration level in one concentration section, n = 6 stands for the 6 results of one concentration level. The relative uncertainty caused by accuracy in one concentration section can be evaluated by the relative standard deviation of relative deviation with different concentration level in one concentration section. According to the error propagation theory, combining the precision uncertainty and the accuracy uncertainty into a global uncertainty, this global uncertainty acted as method uncertainty. This model of evaluating uncertainty can solve a series of difficult questions in the process of evaluating uncertainty, such as uncertainties caused by complex matrix of geological samples, calibration procedure, standard samples, unknown samples, matrix correction, overlap correction, sample preparation, instrument condition and mathematics model. The uncertainty of analytical results in this method can act as the uncertainty of the results of the similar matrix unknown sample in one concentration section. This evaluation model is a basic statistical method owning the practical application value, which can provide a strong base for the building of model of the following uncertainty evaluation function. However, this model used a lot of samples which cannot simply be applied to other types of samples with different matrix samples. The number of samples is too large to adapt to other type's samples. We will strive for using this study as a basis to establish a reasonable basis of mathematical statistics function mode to be applied to different types of samples.

  19. INNOVATIVE TECHNOLOGY EVALUATION REPORT ...

    EPA Pesticide Factsheets

    The Russian Peat Borer designed and fabricated by Aquatic Research Instruments was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation Program in April and May 1999 at sites in EPA Regions 1 and 5, respectively. In addition to assessing ease of sampler operation, key objectives of the demonstration included evaluating the sampler?s ability to (1) consistently collect a given volume of sediment, (2) consistently collect sediment in a given depth interval, (3) collect samples with consistent characteristics from a homogenous layer of sediment, and (4) collect samples under a variety of site conditions. This report describes the demonstration results for the Russian Peat Borer and two conventional samplers (the Hand Corer and Vibrocorer) used as reference samplers. During the demonstration, the Russian Peat Borer was the only sampler that collected samples in the deep depth interval (4 to 11 feet below sediment surface). It collected representative and relatively uncompressed core samples of consolidated sediment in discrete depth intervals. The reference samplers collected relatively compressed samples of both consolidated and unconsolidated sediments from the sediment surface downward; sample representativeness may be questionable because of core shortening and core compression. Sediment stratification was preserved only for consolidated sediment samples collected by the Russian Peat Borer but for bo

  20. Utility of Toca-R Scores during the Elementary School Years in Identifying Later Violence among Adolescent Males

    ERIC Educational Resources Information Center

    Petras, Hanno; Chilcoat, Howard D.; Leaf, Philip J.; Ialongo, Nicholas S.; Kellam, Sheppard G.

    2004-01-01

    Objective: To evaluate the utility of a teacher-rating instrument (TOCA-R) of aggressive behavior during elementary school years in identifying boys at risk for later violence. Method: A community epidemiological sample of 415 public school boys was rated at six time points during elementary school regarding their level of aggressive/disruptive…

  1. The Empathy Index: An Evaluation of the Psychometric Properties of a New Empathy Measure for Sex Offenders

    ERIC Educational Resources Information Center

    Grady, Melissa D.; Rose, Roderick A.

    2011-01-01

    This article examines the analysis of the psychometric properties, including the validity and reliability, of the Empathy Index (EI), a new instrument designed to measure empathy deficits of sex offenders. The EI was tested with a sample of 158 sex offenders incarcerated in North Carolina prisons. An exploratory factor analysis yielded three…

  2. Deconstructing Therapy Outcome Measurement with Rasch Analysis of a Measure of General Clinical Distress: The Symptom Checklist-90-Revised

    ERIC Educational Resources Information Center

    Elliott, Robert; Fox, Christine M.; Beltyukova, Svetlana A.; Stone, Gregory E.; Gunderson, Jennifer; Zhang, Xi

    2006-01-01

    Rasch analysis was used to illustrate the usefulness of item-level analyses for evaluating a common therapy outcome measure of general clinical distress, the Symptom Checklist-90-Revised (SCL-90-R; Derogatis, 1994). Using complementary therapy research samples, the instrument's 5-point rating scale was found to exceed clients' ability to make…

  3. The Construction of a Motor Fitness Test Battery for Boys in the Lower Elementary Grades.

    ERIC Educational Resources Information Center

    DiNucci, James M.; Shore, John Roger

    In order to construct a scientifically designed evaluative instrument to assess the motor fitness of boys in the primary grades, 30 test items purported to measure muscular strength, muscular endurance, cardiovascular endurance, power, speed, agility, flexibility, and balance were administered to an incidental sample of 238 boys ages 6 to 9 years.…

  4. The Utility of Elementary School TOCA-R Scores in Identifying Later Criminal Court Violence Among Adolescent Females

    ERIC Educational Resources Information Center

    Petras, Hanno; Ialongo, Nicholas; Lambert, Sharon F.; Barrueco, Sandra; Schaeffer, Cindy M.; Chilcoat, Howard; Kellam, Sheppard

    2005-01-01

    Objective: To evaluate the utility of a teacher-rating instrument (Teacher Observation of Classroom Adaptation-Revised [TOCA-R]) of aggressive behavior during elementary school years in identifying girls at risk of later criminal court violence. Method: A community epidemiological sample of 845 urban public school girls was rated at six time…

  5. Screening for Autism in Iranian Preschoolers: Contrasting M-CHAT and a Scale Developed in Iran

    ERIC Educational Resources Information Center

    Samadi, Sayyed Ali; McConkey, Roy

    2015-01-01

    Suitable screening instruments for the early diagnosis of autism are not readily available for use with preschoolers in non-Western countries. This study evaluated two tools: M-CHAT which is widely used internationally and one developed in Iran called Hiva. A population sample was recruited of nearly 3000 preschoolers in one Iranian city. Parents…

  6. Are Community Studies of Psychological Trauma's Impact Accurate? A Study among Jews and Palestinians

    ERIC Educational Resources Information Center

    Hobfoll, Stevan E.; Canetti, Daphna; Hall, Brian J.; Brom, Danny; Palmieri, Patrick A.; Johnson, Robert J.; Pat-Horenczyk, Ruth; Galea, Sandro

    2011-01-01

    We evaluated the accuracy of posttraumatic stress disorder (PTSD) and major depression (MD) diagnoses using brief assessment instruments conducted by phone. PTSD and MD were assessed by telephone interview in a randomly selected sample of Jewish and Palestinian residents of Jerusalem (N = 150) during a period of marked threat of terrorism and war.…

  7. Progress Monitoring Instrument Development: Silent Reading Fluency, Vocabulary, and Reading Comprehension. Technical Report #1110

    ERIC Educational Resources Information Center

    Nese, Joseph F. T.; Anderson, Daniel; Hoelscher, Kyle; Tindal, Gerald; Alonzo, Julie

    2011-01-01

    Curriculum-based measurement (CBM) is designed to measure students' academic status and growth so the effectiveness of instruction may be evaluated. In the most popular forms of reading CBM, the student's oral reading fluency is assessed. This behavior is difficult to sample in a computer-based format, a limitation that may be a function of the…

  8. Effects of Language Learning Interventions in Pre-School Children: A Longitudinal Study

    ERIC Educational Resources Information Center

    Gasteiger-Klicpera, B.; Knapp, W.; Kucharz, D.; Schabmann, A.; Schmidt, B.

    2009-01-01

    The aim of the present contribution is to evaluate and discuss the impacts of language learning interventions in pre-school children with German as a first or a second language. The sample consisted of 864 children in intervention groups and 294 children as a comparison group within two successive cohorts. The instruments used were the SSV (Grimm…

  9. Development of a computer-adaptive physical function instrument for Social Security Administration disability determination.

    PubMed

    Ni, Pengsheng; McDonough, Christine M; Jette, Alan M; Bogusz, Kara; Marfeo, Elizabeth E; Rasch, Elizabeth K; Brandt, Diane E; Meterko, Mark; Haley, Stephen M; Chan, Leighton

    2013-09-01

    To develop and test an instrument to assess physical function for Social Security Administration (SSA) disability programs, the SSA-Physical Function (SSA-PF) instrument. Item response theory (IRT) analyses were used to (1) create a calibrated item bank for each of the factors identified in prior factor analyses, (2) assess the fit of the items within each scale, (3) develop separate computer-adaptive testing (CAT) instruments for each scale, and (4) conduct initial psychometric testing. Cross-sectional data collection; IRT analyses; CAT simulation. Telephone and Internet survey. Two samples: SSA claimants (n=1017) and adults from the U.S. general population (n=999). None. Model fit statistics, correlation, and reliability coefficients. IRT analyses resulted in 5 unidimensional SSA-PF scales: Changing & Maintaining Body Position, Whole Body Mobility, Upper Body Function, Upper Extremity Fine Motor, and Wheelchair Mobility for a total of 102 items. High CAT accuracy was demonstrated by strong correlations between simulated CAT scores and those from the full item banks. On comparing the simulated CATs with the full item banks, very little loss of reliability or precision was noted, except at the lower and upper ranges of each scale. No difference in response patterns by age or sex was noted. The distributions of claimant scores were shifted to the lower end of each scale compared with those of a sample of U.S. adults. The SSA-PF instrument contributes important new methodology for measuring the physical function of adults applying to the SSA disability programs. Initial evaluation revealed that the SSA-PF instrument achieved considerable breadth of coverage in each content domain and demonstrated noteworthy psychometric properties. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  10. Development of the evaluation instrument use CIPP on the implementation of project assessment topic optik

    NASA Astrophysics Data System (ADS)

    Asfaroh, Jati Aurum; Rosana, Dadan; Supahar

    2017-08-01

    This research aims to develop an evaluation instrument models CIPP valid and reliable as well as determine the feasibility and practicality of an evaluation instrument models CIPP. An evaluation instrument models CIPP to evaluate the implementation of the project assessment topic optik to measure problem-solving skills of junior high school class VIII in the Yogyakarta region. This research is a model of development that uses 4-D. Subject of product trials are students in class VIII SMP N 1 Galur and SMP N 1 Sleman. Data collection techniques in this research using non-test techniques include interviews, questionnaires and observations. Validity in this research was analyzed using V'Aikens. Reliability analyzed using ICC. This research uses 7 raters are derived from two lecturers expert (expert judgment), two practitioners (science teacher) and three colleagues. The results of this research is the evaluation's instrument model of CIPP is used to evaluate the implementation of the implementation of the project assessment instruments. The validity result of evaluation instrument have V'Aikens values between 0.86 to 1, which means a valid and 0.836 reliability values into categories so well that it has been worth used as an evaluation instrument.

  11. Lunar Reference Suite to Support Instrument Development and Testing

    NASA Technical Reports Server (NTRS)

    Allen, Carlton; Sellar, Glenn; Nunez, Jorge I.; Winterhalter, Daniel; Farmer, Jack

    2010-01-01

    Astronauts on long-duration lunar missions will need the capability to "high-grade" their samples - to select the highest value samples for transport to Earth - and to leave others on the Moon. Instruments that may be useful for such high-grading are under development. Instruments are also being developed for possible use on future lunar robotic landers, for lunar field work, and for more sophisticated analyses at a lunar outpost. The Johnson Space Center Astromaterials acquisition and Curation Office (JSC Curation) wll support such instrument testing by providing lunar sample "ground truth".

  12. Effect of Autoclave Cycles on Surface Characteristics of S-File Evaluated by Scanning Electron Microscopy.

    PubMed

    Razavian, Hamid; Iranmanesh, Pedram; Mojtahedi, Hamid; Nazeri, Rahman

    2016-01-01

    Presence of surface defects in endodontic instruments can lead to unwanted complications such as instrument fracture and incomplete preparation of the canal. The current study was conducted to evaluate the effect of autoclave cycles on surface characteristics of S-File by scanning electron microscopy (SEM). In this experimental study, 17 brand new S-Files (#30) were used. The surface characteristics of the files were examined in four steps (without autoclave, 1 autoclave cycle, 5 autoclave cycles and 10 autoclave cycles) by SEM under 200× and 1000× magnifications. Data were analyzed using the SPSS software and the paired sample t-test, independent sample t-test and multifactorial repeated measures ANOVA. The level of significance was set at 0.05. New files had debris and pitting on their surfaces. When the autoclave cycles were increased, the mean of surface roughness also increased at both magnifications (P<0.05). Moreover, under 1000× magnification the multifactorial repeated measures ANOVA showed more surface roughness (P<0.001). Sterilization by autoclave increased the surface roughness of the files and this had was directly related to the number of autoclave cycles.

  13. Effect of Autoclave Cycles on Surface Characteristics of S-File Evaluated by Scanning Electron Microscopy

    PubMed Central

    Razavian, Hamid; Iranmanesh, Pedram; Mojtahedi, Hamid; Nazeri, Rahman

    2016-01-01

    Introduction: Presence of surface defects in endodontic instruments can lead to unwanted complications such as instrument fracture and incomplete preparation of the canal. The current study was conducted to evaluate the effect of autoclave cycles on surface characteristics of S-File by scanning electron microscopy (SEM). Methods and Materials: In this experimental study, 17 brand new S-Files (#30) were used. The surface characteristics of the files were examined in four steps (without autoclave, 1 autoclave cycle, 5 autoclave cycles and 10 autoclave cycles) by SEM under 200× and 1000× magnifications. Data were analyzed using the SPSS software and the paired sample t-test, independent sample t-test and multifactorial repeated measures ANOVA. The level of significance was set at 0.05. Results: New files had debris and pitting on their surfaces. When the autoclave cycles were increased, the mean of surface roughness also increased at both magnifications (P<0.05). Moreover, under 1000× magnification the multifactorial repeated measures ANOVA showed more surface roughness (P<0.001). Conclusion: Sterilization by autoclave increased the surface roughness of the files and this had was directly related to the number of autoclave cycles. PMID:26843874

  14. The Evaluation of a Low-Cost Colorimeter for Glucose Detection in Salivary Samples.

    PubMed

    Dominguez, Rocio B; Orozco, Miguel A; Chávez, Giovanny; Márquez-Lucero, Alfredo

    2017-11-01

    Given the limited access to healthcare resources, low-income settings require the development of affordable technology. Here we present the design and evaluation of a low-cost colorimeter applied to the non-invasive monitoring of Diabetes Mellitus through the detection of glucose in salival fluid. Samples were processed by the glucose oxidase-peroxidase enzymatic system and analyzed with the development equipment. A light emission diode of 532.5 nm was used as an excitation source and a RGB module was used as a receptor. A calibration curve to quantify the concentration of salivary glucose (0 to 18 mg/dL) was carried out by relating the RGB components registered with glucose concentrations, achieving a limit of detection of 0.17 mg/dL with a CV of 5% (n = 3). Salivary samples of diabetic and healthy volunteers were processed with the equipment showing an average concentration of 1.5519 ± 0.4511 mg/dL for the first and 4.0479 ± 1.6103 mg/dL for the last, allowing a discrimination between both groups. Results were validated against a UV-Vis-NIR spectrophotometer with a correspondence of R² of 0.98194 between both instruments. Results suggest the potential application of the developed device to the sensitive detection of relevant analytes with a low-cost, user-friendly, low-power and portable instrumentation.

  15. The Evaluation of a Low-Cost Colorimeter for Glucose Detection in Salivary Samples

    PubMed Central

    Dominguez, Rocio B.; Orozco, Miguel A.; Chávez, Giovanny; Márquez-Lucero, Alfredo

    2017-01-01

    Given the limited access to healthcare resources, low-income settings require the development of affordable technology. Here we present the design and evaluation of a low-cost colorimeter applied to the non-invasive monitoring of Diabetes Mellitus through the detection of glucose in salival fluid. Samples were processed by the glucose oxidase-peroxidase enzymatic system and analyzed with the development equipment. A light emission diode of 532.5 nm was used as an excitation source and a RGB module was used as a receptor. A calibration curve to quantify the concentration of salivary glucose (0 to 18 mg/dL) was carried out by relating the RGB components registered with glucose concentrations, achieving a limit of detection of 0.17 mg/dL with a CV of 5% (n = 3). Salivary samples of diabetic and healthy volunteers were processed with the equipment showing an average concentration of 1.5519 ± 0.4511 mg/dL for the first and 4.0479 ± 1.6103 mg/dL for the last, allowing a discrimination between both groups. Results were validated against a UV-Vis-NIR spectrophotometer with a correspondence of R2 of 0.98194 between both instruments. Results suggest the potential application of the developed device to the sensitive detection of relevant analytes with a low-cost, user-friendly, low-power and portable instrumentation. PMID:29104212

  16. Cross-cultural adaptation, evaluation and validation of the Spouse Response Inventory: a study protocol.

    PubMed

    Kaiser, Ulrike; Steinmetz, Dorit; Scharnagel, Rüdiger; Jensen, Mark P; Balck, Friedrich; Sabatowski, Rainer

    2014-10-14

    Since the response of spouses has been proven to be an important reinforcement of pain behaviour and disability it has been addressed in research and therapy. Fordyce suggested pain behaviour and well behaviour be considered in explaining suffering in chronic pain patients. Among existing instruments concerning spouse's responses the aspect of well behaviour has not been examined so far. The SRI (Spouse Response Inventory) tries to consider pain behaviour and well behaviour and appears to be acceptable because of its brevity and close proximity to daily language. The aim of the study is the translation into German, followed by evaluation and validation, of the SRI on a German sample of patients with chronic pain. The study is comprehensively designed: initially, the focus will lie on the translation of the instrument following the guidelines for cross-cultural translation and adaptation and evaluation of the German version according to the source study. Subsequently, a validation referring to predictive, incremental and construct validation will be conducted using instruments based on similar or close but different constructs. Evaluation of the resulting SRI-G (SRI-German) will be conducted on a sample of at least 30 patients with chronic pain attending a comprehensive pain centre. For validation at least 120 patients with chronic headache, back pain, cancer related pain and somatoform pain disorder shall be included, for a total of 480 patients. Separate analyses according to specific pain diagnoses will be performed to ensure psychometric property, interpretability and control of diagnosis of specific limitations. Analyses will include comprehensive investigation of psychometric property of the scale by hierarchical regression analyses, correlation analyses, multivariate analysis of variance and exploratory factor analyses (SPSS). The study protocol was approved by the Ethics Committee of the University of Dresden (EK 335 122008) based on the Helsinki declaration. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. Characterizing sampling and quality screening biases in infrared and microwave limb sounding

    NASA Astrophysics Data System (ADS)

    Millán, Luis F.; Livesey, Nathaniel J.; Santee, Michelle L.; von Clarmann, Thomas

    2018-03-01

    This study investigates orbital sampling biases and evaluates the additional impact caused by data quality screening for the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) and the Aura Microwave Limb Sounder (MLS). MIPAS acts as a proxy for typical infrared limb emission sounders, while MLS acts as a proxy for microwave limb sounders. These biases were calculated for temperature and several trace gases by interpolating model fields to real sampling patterns and, additionally, screening those locations as directed by their corresponding quality criteria. Both instruments have dense uniform sampling patterns typical of limb emission sounders, producing almost identical sampling biases. However, there is a substantial difference between the number of locations discarded. MIPAS, as a mid-infrared instrument, is very sensitive to clouds, and measurements affected by them are thus rejected from the analysis. For example, in the tropics, the MIPAS yield is strongly affected by clouds, while MLS is mostly unaffected. The results show that upper-tropospheric sampling biases in zonally averaged data, for both instruments, can be up to 10 to 30 %, depending on the species, and up to 3 K for temperature. For MIPAS, the sampling reduction due to quality screening worsens the biases, leading to values as large as 30 to 100 % for the trace gases and expanding the 3 K bias region for temperature. This type of sampling bias is largely induced by the geophysical origins of the screening (e.g. clouds). Further, analysis of long-term time series reveals that these additional quality screening biases may affect the ability to accurately detect upper-tropospheric long-term changes using such data. In contrast, MLS data quality screening removes sufficiently few points that no additional bias is introduced, although its penetration is limited to the upper troposphere, while MIPAS may cover well into the mid-troposphere in cloud-free scenarios. We emphasize that the results of this study refer only to the representativeness of the respective data, not to their intrinsic quality.

  18. CIEL*a*b* color space predictive models for colorimetry devices--analysis of perfume quality.

    PubMed

    Korifi, Rabia; Le Dréau, Yveline; Antinelli, Jean-François; Valls, Robert; Dupuy, Nathalie

    2013-01-30

    Color perception plays a major role in the consumer evaluation of perfume quality. Consumers need first to be entirely satisfied with the sensory properties of products, before other quality dimensions become relevant. The evaluation of complex mixtures color presents a challenge even for modern analytical techniques. A variety of instruments are available for color measurement. They can be classified as tristimulus colorimeters and spectrophotometers. Obsolescence of the electronics of old tristimulus colorimeter arises from the difficulty in finding repair parts and leads to its replacement by more modern instruments. High quality levels in color measurement, i.e., accuracy and reliability in color control are the major advantages of the new generation of color instrumentation, the integrating sphere spectrophotometer. Two models of spectrophotometer were tested in transmittance mode, employing the d/0° geometry. The CIEL(*)a(*)b(*) color space parameters were measured with each instrument for 380 samples of raw materials and bases used in the perfume compositions. The results were graphically compared between the colorimeter device and the spectrophotometer devices. All color space parameters obtained with the colorimeter were used as dependent variables to generate regression equations with values obtained from the spectrophotometers. The data was statistically analyzed to create predictive model between the reference and the target instruments through two methods. The first method uses linear regression analysis and the second method consists of partial least square regression (PLS) on each component. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Indoor and Outdoor Mobile Mapping Systems for Architectural Surveys

    NASA Astrophysics Data System (ADS)

    Campi, M.; di Luggo, A.; Monaco, S.; Siconolfi, M.; Palomba, D.

    2018-05-01

    This paper presents the results of architectural surveys carried out with mobile mapping systems. The data acquired through different instruments for both indoor and outdoor surveying are analyzed and compared. The study sample shows what is required for an acquisition in a dynamic mode indicating the criteria for the creation of a georeferenced network for indoor spaces, as well as the operational processes concerning data capture, processing, and management. The differences between a dynamic and static scan have been evaluated, with a comparison being made with the aerial photogrammetric survey of the same sample.

  20. Study on the applicability of a precise, accurate method for rapid evaluation of engine and lubricant performance. [determination of wear metal in used lubricating oils

    NASA Technical Reports Server (NTRS)

    Kinard, J. T.

    1975-01-01

    The development of a procedure for obtaining data related to wear metal determinations in used lubricants is discussed. The procedure makes it possible to obtain rapid, simultaneous determinations of a number of wear metals at levels of parts per thousand to low parts per billion using a small amount of sample. The electrode assembly and instrumentation used in the process are described. Samples of data obtained from tests conducted under controlled conditions are tabulated.

  1. Evaluative frailty index for physical activity (EFIP): a reliable and valid instrument to measure changes in level of frailty.

    PubMed

    de Vries, Nienke M; Staal, J Bart; Olde Rikkert, Marcel G M; Nijhuis-van der Sanden, Maria W G

    2013-04-01

    Physical activity is assumed to be important in the prevention and treatment of frailty. It is unclear, however, to what extent frailty can be influenced because instruments designed to assess frailty have not been validated as evaluative outcome instruments in clinical practice. The aims of this study were: (1) to develop a frailty index (i.e., the evaluative frailty index for physical activity [EFIP]) based on the method of deficit accumulation and (2) to test the clinimetric properties of the EFIP. The content of the EFIP was determined using a written Delphi procedure. Intrarater reliability, interrater reliability, and construct validity were determined in an observational study (n=24). Intrarater reliability and interrater reliability were calculated using Cohen kappa and intraclass correlation coefficients (ICCs). Construct validity was determined by correlating the score on the EFIP with those on the timed "up & go" test (TUG), the performance-oriented mobility assessment (POMA), and the Cumulative Illness Rating Scale for Geriatrics (CIRS-G). Fifty items were included in the EFIP. Interrater reliability (Cohen kappa=0.72, ICC=.96) and intrarater reliability (Cohen kappa=0.77 and 0.80, ICC=.93 and .98) were good. As expected, a fair to moderate correlation with the TUG, POMA, and CIRS-G was found (.61, -.70, and .66, respectively). Reliability and validity of the EFIP have been tested in a small sample. These and other clinimetric properties, such as responsiveness, will be assessed or reassessed in a larger study population. The EFIP is a reliable and valid instrument to evaluate the effect of physical activity on frailty in research and in clinical practice.

  2. A proposal for assessing study quality: Biomonitoring, Environmental Epidemiology, and Short-lived Chemicals (BEES-C) instrument.

    PubMed

    LaKind, Judy S; Sobus, Jon R; Goodman, Michael; Barr, Dana Boyd; Fürst, Peter; Albertini, Richard J; Arbuckle, Tye E; Schoeters, Greet; Tan, Yu-Mei; Teeguarden, Justin; Tornero-Velez, Rogelio; Weisel, Clifford P

    2014-12-01

    The quality of exposure assessment is a major determinant of the overall quality of any environmental epidemiology study. The use of biomonitoring as a tool for assessing exposure to ubiquitous chemicals with short physiologic half-lives began relatively recently. These chemicals present several challenges, including their presence in analytical laboratories and sampling equipment, difficulty in establishing temporal order in cross-sectional studies, short- and long-term variability in exposures and biomarker concentrations, and a paucity of information on the number of measurements required for proper exposure classification. To date, the scientific community has not developed a set of systematic guidelines for designing, implementing and interpreting studies of short-lived chemicals that use biomonitoring as the exposure metric or for evaluating the quality of this type of research for WOE assessments or for peer review of grants or publications. We describe key issues that affect epidemiology studies using biomonitoring data on short-lived chemicals and propose a systematic instrument--the Biomonitoring, Environmental Epidemiology, and Short-lived Chemicals (BEES-C) instrument--for evaluating the quality of research proposals and studies that incorporate biomonitoring data on short-lived chemicals. Quality criteria for three areas considered fundamental to the evaluation of epidemiology studies that include biological measurements of short-lived chemicals are described: 1) biomarker selection and measurement, 2) study design and execution, and 3) general epidemiological study design considerations. We recognize that the development of an evaluative tool such as BEES-C is neither simple nor non-controversial. We hope and anticipate that the instrument will initiate further discussion/debate on this topic. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. A proposal for assessing study quality: Biomonitoring, Environmental Epidemiology, and Short-lived Chemicals (BEES-C) instrument

    PubMed Central

    LaKind, Judy S.; Sobus, Jon R.; Goodman, Michael; Barr, Dana Boyd; Fürst, Peter; Albertini, Richard J.; Arbuckle, Tye E.; Schoeters, Greet; Tan, Yu-Mei; Teeguarden, Justin; Tornero-Velez, Rogelio; Weisel, Clifford P.

    2015-01-01

    The quality of exposure assessment is a major determinant of the overall quality of any environmental epidemiology study. The use of biomonitoring as a tool for assessing exposure to ubiquitous chemicals with short physiologic half-lives began relatively recently. These chemicals present several challenges, including their presence in analytical laboratories and sampling equipment, difficulty in establishing temporal order in cross-sectional studies, short- and long-term variability in exposures and biomarker concentrations, and a paucity of information on the number of measurements required for proper exposure classification. To date, the scientific community has not developed a set of systematic guidelines for designing, implementing and interpreting studies of short-lived chemicals that use biomonitoring as the exposure metric or for evaluating the quality of this type of research for WOE assessments or for peer review of grants or publications. We describe key issues that affect epidemiology studies using biomonitoring data on short-lived chemicals and propose a systematic instrument – the Biomonitoring, Environmental Epidemiology, and Short-lived Chemicals (BEES-C) instrument – for evaluating the quality of research proposals and studies that incorporate biomonitoring data on short-lived chemicals. Quality criteria for three areas considered fundamental to the evaluation of epidemiology studies that include biological measurements of short-lived chemicals are described: 1) biomarker selection and measurement, 2) study design and execution, and 3) general epidemiological study design considerations. We recognize that the development of an evaluative tool such as BEES-C is neither simple nor non-controversial. We hope and anticipate that the instrument will initiate further discussion/debate on this topic. PMID:25137624

  4. Automated multimodal spectral histopathology for quantitative diagnosis of residual tumour during basal cell carcinoma surgery.

    PubMed

    Boitor, Radu; Kong, Kenny; Shipp, Dustin; Varma, Sandeep; Koloydenko, Alexey; Kulkarni, Kusum; Elsheikh, Somaia; Schut, Tom Bakker; Caspers, Peter; Puppels, Gerwin; van der Wolf, Martin; Sokolova, Elena; Nijsten, T E C; Salence, Brogan; Williams, Hywel; Notingher, Ioan

    2017-12-01

    Multimodal spectral histopathology (MSH), an optical technique combining tissue auto-fluorescence (AF) imaging and Raman micro-spectroscopy (RMS), was previously proposed for detection of residual basal cell carcinoma (BCC) at the surface of surgically-resected skin tissue. Here we report the development of a fully-automated prototype instrument based on MSH designed to be used in the clinic and operated by a non-specialist spectroscopy user. The algorithms for the AF image processing and Raman spectroscopy classification had been first optimised on a manually-operated laboratory instrument and then validated on the automated prototype using skin samples from independent patients. We present results on a range of skin samples excised during Mohs micrographic surgery, and demonstrate consistent diagnosis obtained in repeat test measurement, in agreement with the reference histopathology diagnosis. We also show that the prototype instrument can be operated by clinical users (a skin surgeon and a core medical trainee, after only 1-8 hours of training) to obtain consistent results in agreement with histopathology. The development of the new automated prototype and demonstration of inter-instrument transferability of the diagnosis models are important steps on the clinical translation path: it allows the testing of the MSH technology in a relevant clinical environment in order to evaluate its performance on a sufficiently large number of patients.

  5. Nanophase Carbonates on Mars: Does Evolved Gas Analysis of Nanophase Carbonates Reveal a Large Organic Carbon Budget in Near-surface Martian Materials?

    NASA Astrophysics Data System (ADS)

    Archer, P. D., Jr.; Ming, D. W.; Sutter, B.; Niles, P. B.; Eigenbrode, J. L.

    2015-12-01

    Evolved Gas Analysis (EGA), which involves heating a sample and monitoring the gases released, has been performed on Mars by the Viking gas chromatography/mass spectrometry instruments, the Thermal and Evolved Gas Analyzer (TEGA) on the Phoenix lander, and the Sample Analysis at Mars (SAM) instrument on the Mars Science Laboratory. All of these instruments detected CO2 released during sample analysis at abundances of ~0.1 to 5 wt% assuming a carbonate source. The source of the CO2 can be constrained by evaluating the temperature of the gas release, a capability of both the TEGA and SAM instruments. The samples analyzed by SAM show that the majority of the CO2is released below 400 °C, much lower than traditional carbonate decomposition temperatures which can be as low as 400 °C for some siderites, with magnesites and calcites decomposing at even higher temperatures. In addition to mineralogy, decomposition temperature can depend on particle size (among other factors). If carbonates formed on Mars under low temperature and relative humidity conditions, the resulting small particle size (nanophase) carbonates could have low decomposition temperatures. We have found that calcite can be synthesized by exposing CaO to water vapor and CO2 and that the resulting mineral has an EGA peak of ~550 °C for CO2, which is about 200 °C lower than for other calcites. Work is ongoing to produce Fe and Mg-bearing carbonates using the same process. Current results suggest that nanophase calcium carbonates cannot explain the CO2 released from martian samples. If the decomposition temperatures of Mg and Fe-bearing nanophase carbonates are not significantly lower than 400 °C, other candidate sources include oxalates and carboxylated organic molecules. If present, the abundance of organic carbon in these samples could be > 0.1 wt % (1000s of ppm), a signficant departure from the paradigm of the organic-poor Mars based on Viking results.

  6. Developing a Survey Instrument for Evaluating the Effectiveness of Data Management Training Materials

    NASA Astrophysics Data System (ADS)

    Hou, C. Y.; Soyka, H.; Hutchison, V.; Budden, A. E.

    2016-12-01

    Education and training resources that focus on best practices and guidelines for working with data such as: data management, data sharing, quality metadata creation, and maintenance for reuse, have vital importance not only to the users of Data Observation Network for Earth (DataONE), but also to the broader scientific, research, and academic communities. However, creating and maintaining relevant training/educational materials that remain sensitive and responsive to community needs is dependent upon careful evaluations of the current landscape in order to promote and support thoughtful development of new resources. Using DataONE's existing training/educational resources as the basis for this project, the authors have worked to develop an evaluation instrument that can be used to evaluate the effectiveness of data management training/education resources. The evaluation instrument is in the form of a digital questionnaire/survey. The evaluation instrument also includes the structure and content as recommended by the best practices/guidelines of questionnaire/survey design, based on a review of the literature. Additionally, the evaluation instrument can be customized to evaluate various training/education modalities and be implemented using a web-based questionnaire/survey platform. Finally, the evaluation instrument can be used for site-wide evaluation of DataONE teaching materials and resources, and once made publicly available and openly accessible, other organizations may also utilize the instrument. One key outcome of developing the evaluation instrument is to help in increasing the effectiveness of data management training/education resources across the Earth/Geoscience community. Through this presentation, the authors will provide the full background and motivations for creating an instrument for evaluating the effectiveness of data management training/education resources. The presentation will also discuss in detail the process and results of the current version of the evaluation instrument. Finally, the presentation will highlight the key features and the next steps to examine in order to improve the next revisions of the instrument.

  7. A New Approach of Personality and Psychiatric Disorders: A Short Version of the Affective Neuroscience Personality Scales

    PubMed Central

    Pingault, Jean-Baptiste; Falissard, Bruno; Côté, Sylvana; Berthoz, Sylvie

    2012-01-01

    Background The Affective Neuroscience Personality Scales (ANPS) is an instrument designed to assess endophenotypes related to activity in the core emotional systems that have emerged from affective neuroscience research. It operationalizes six emotional endophenotypes with empirical evidence derived from ethology, neural analyses and pharmacology: PLAYFULNESS/joy, SEEKING/interest, CARING/nurturance, ANGER/rage, FEAR/anxiety, and SADNESS/separation distress. We aimed to provide a short version of this questionnaire (ANPS-S). Methodology/Principal Findings We used a sample of 830 young French adults which was randomly split into two subsamples. The first subsample was used to select the items for the short scales. The second subsample and an additional sample of 431 Canadian adults served to evaluate the psychometric properties of the short instrument. The ANPS-S was similar to the long version regarding intercorrelations between the scales and gender differences. The ANPS-S had satisfactory psychometric properties, including factorial structure, unidimensionality of all scales, and internal consistency. The scores from the short version were highly correlated with the scores from the long version. Conclusions/Significance The short ANPS proves to be a promising instrument to assess endophenotypes for psychiatrically relevant science. PMID:22848510

  8. Construction and evaluation of an inexpensive weighing lysimeter for studying contaminant transport

    NASA Astrophysics Data System (ADS)

    Corwin, D. L.; LeMert, R. D.

    1994-01-01

    A description is provided of an above-ground, weighing lysimeter that minimizes the edge flow of water which can occur between the soil and the wall of the casing. The lysimeter was designed to study water flux and the movement of inorganic and/or organic pollutants as they pass through and beyond the root zone. The lysimeter is instrumented at selected depths with thermistors, soil solution extractors, time-domain reflectometry probes, gas extractors and tensiometers. These sensors provide temperature measurements, soil solution samples, water content measurements, soil atmosphere samples and water potential measurements. The horizontal insertion of these instruments from the side of the lysimeter reduces and channeling that might occur along the sides of the instruments, if they had been inserted vertically. Annular-ring baffles are located at selected depths to reduce edge flow between the lysimeter casing and the column of soil. The baffles redirect water flow away from the edge of the column. Data are presented that show a reduction in the hydraulic bypass of the lysimeter compared to a lysimeter without baffles. The total cost of a single lysimeter including materials and labor is under US $4000.

  9. Rural parents' perceived stigma of seeking mental health services for their children: development and evaluation of a new instrument.

    PubMed

    Williams, Stacey L; Polaha, Jodi

    2014-09-01

    The purpose of our research was to examine the validity of score interpretations of an instrument developed to measure parents' perceptions of stigma about seeking mental health services for their children. The validity of the score interpretations of the instrument was tested in 2 studies. Study 1 employed confirmatory factor analysis (CFA), using a split half approach, and construct and criterion validity on data from the entire sample of parents in rural Appalachia whose children were experiencing psychosocial concerns (N = 347), while Study 2 employed CFA, construct and criterion validity, and predictive validity of the scores on data from a general sample of parents in rural Appalachia (N = 184). Results of exploratory and confirmatory factor analyses revealed support for a 2-factor model of parents' perceived stigma, which represented both self and public forms of stigma associated with seeking mental health services for their children, and correlated with existing measures of stigma and other psychosocial variables. Further, the new self and public stigma scale significantly predicted parents' willingness to seek services for children. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  10. A field instrument for quantitative determination of beryllium by activation analysis

    USGS Publications Warehouse

    Vaughn, William W.; Wilson, E.E.; Ohm, J.M.

    1960-01-01

    A low-cost instrument has been developed for quantitative determinations of beryllium in the field by activation analysis. The instrument makes use of the gamma-neutron reaction between gammas emitted by an artificially radioactive source (Sb124) and beryllium as it occurs in nature. The instrument and power source are mounted in a panel-type vehicle. Samples are prepared by hand-crushing the rock to approximately ?-inch mesh size and smaller. Sample volumes are kept constant by means of a standard measuring cup. Instrument calibration, made by using standards of known BeO content, indicates the analyses are reproducible and accurate to within ? 0.25 percent BeO in the range from 1 to 20 percent BeO with a sample counting time of 5 minutes. Sensitivity of the instrument maybe increased somewhat by increasing the source size, the sample size, or by enlarging the cross-sectional area of the neutron-sensitive phosphor normal to the neutron flux.

  11. Validation of the Spanish version of the "Questionnaire on the treatment of approximal and occlusal caries".

    PubMed

    Ruiz, Begoña; Urzúa, Iván; Cabello, Rodrigo; Rodríguez, Gonzalo; Espelid, Ivar

    2013-01-01

    To translate and validate a Spanish version of the "Questionnaire on the treatment of approximal and occlusal caries" as a method of collecting information about treatment decisions on caries management in Chilean primary health care services. The original questionnaire proposed by Espelid et al. was translated into Spanish using the forward-backward translation technique. Subsequently, validation of the Spanish version was undertaken. Data were collected from two separate samples; first, from 132 Spanish-speaking dentists recruited from primary health care services and second, from 21 individuals characterised as cariologists. Internal consistency was evaluated by the generation of Cronbach's alpha, test-retest reliability was evaluated by Cohen's kappa, convergent validity was evaluated by comparing the total scale scores to a global evaluation of treatment trends and discriminant validity was evaluated by investigating the differences in total scale scores between the Spanish-speaking dentist and cariologist samples. Cronbach's alpha indicated an internal consistency of 0.63 for the entire scale. Cohen's kappa correlation coefficient expressed a test-retest reliability of 0.83. Convergent validity determined a Pearson's correlation coefficient of 0.24 (p < 0.01). The comparison of proportions (chi-squared) indicated that discriminant validity was statistically significant (p < 0.01), using a one-tailed test. The Spanish version of the "Questionnaire on the treatment of approximal and occlusal caries" is a valid and reliable instrument for collecting information regarding treatment decisions in cariology. The clinical relevance of this study is to acquire a reliable instrument that allows for the determination of treatment decisions in Spanish-speaking dentists.

  12. [Short Spanish version of Team Climate Inventory (TCI-14): development and psychometric properties].

    PubMed

    Boada-Grau, Joan; de Diego-Vallejo, Raúl; de Llanos-Serra, Emma; Vigil-Colet, Andreu

    2011-04-01

    The aim of the present paper was to develop a Spanish adaptation of the reduced, 14-item version of the Team Climate Inventory (TCI-14), a questionnaire developed to evaluate team climate. To this end the English version was adapted and applied to a sample of 360 employees from Castilla-León and Catalonia (44.4% men and 55.6% women). The results indicated that the TCI-14 has the same structure as the original version, and confirmatory factor analysis was used to verify the existence of the factors Vision, Participative Safety, Task Orientation and Support for Innovation. The TCI-14 also presented good reliability coefficients considering the low number of items on each scale (alphas ranged between .75 and .82). The TCI-14 is a potentially useful instrument for evaluating the climate of work teams. It could be used by future research as a screening tool in conjunction with other instruments.

  13. Childhood lead poisoning investigations: evaluating a portable instrument for testing soil lead.

    PubMed

    Reames, Ginger; Lance, Larrie L

    2002-04-01

    The Childhood Lead Poisoning Prevention Branch of the California Department of Health Services evaluated a portable X-ray fluorescence (XRF) instrument for use as a soil lead-testing tool during environmental investigations of lead-poisoned children's homes. A Niton XRF was used to test soil at 119 sampling locations in the yards of 11 San Francisco Bay Area houses. Niton XRF readings were highly correlated with laboratory results and met the study criteria for an acceptable screening method. The data suggest that the most health-protective and time-efficient approach to testing for soil lead above regulatory levels is to take either surface readings or readings of a test cup of soil prepared by grinding with a mortar and pestle. The advantage of the test cup method is that the test cup with soil may be submitted to a laboratory for confirmatory analysis.

  14. Gas turbine coatings eddy current quantitative and qualitative evaluation

    NASA Astrophysics Data System (ADS)

    Ribichini, Remo; Giolli, Carlo; Scrinzi, Erica

    2017-02-01

    Gas turbine blades (buckets) are among the most critical and expensive components of the engine. Buckets rely on protective coatings in order to withstand the harsh environment in which they operate. The thickness and the microstructure of coatings during the lifespan of a unit are fundamental to evaluate their fitness for service. A frequency scanning Eddy Current instrument can allow the measurement of the thickness and of physical properties of coatings in a Non-Destructive manner. The method employed relies on the acquisition of impedance spectra and on the inversion of the experimental data to derive the coating properties and structure using some assumptions. This article describes the experimental validation performed on several samples and real components in order to assess the performance of the instrument as a coating thickness gage. The application of the technique to support residual life assessment of serviced buckets is also presented.

  15. Polarization analysis for magnetic field imaging at RADEN in J-PARC/MLF

    NASA Astrophysics Data System (ADS)

    Shinohara, Takenao; Hiroi, Kosuke; Su, Yuhua; Kai, Tetsuya; Nakatani, Takeshi; Oikawa, Kenichi; Segawa, Mariko; Hayashida, Hirotoshi; Parker, Joseph D.; Matsumoto, Yoshihiro; Zhang, Shuoyuan; Kiyanagi, Yoshiaki

    2017-06-01

    Polarized neutron imaging is an attractive method for visualizing magnetic fields in a bulk object or in free space. In this technique polarization of neutrons transmitted through a sample is analyzed position by position to produce an image of the polarization distribution. In particular, the combination of three-dimensional spin analysis and the use of a pulsed neutron beam is very effective for the quantitative evaluation of both field strength and direction by means of the analysis of the wavelength dependent polarization vector. Recently a new imaging instrument “RADEN” has been constructed at the beam line of BL22 of the Materials and Life Science Experimental Facility (MLF) at J-PARC, which is dedicated to energy-resolved neutron imaging experiments. We have designed a polarization analysis apparatus for magnetic field imaging at the RADEN instrument and have evaluated its performance.

  16. Mercury and gold concentrations of highly polluted environmental samples determined using prompt gamma-ray analysis and instrument neutron activation analysis

    NASA Astrophysics Data System (ADS)

    Osawa, Takahito; Hatsukawa, Yuichi; Appel, Peter W. U.; Matsue, Hideaki

    2011-04-01

    The authors have established a method of determining mercury and gold in severely polluted environmental samples using prompt gamma-ray analysis (PGA) and instrumental neutron activation analysis (INAA). Since large amounts of mercury are constantly being released into the environment by small-scale gold mining in many developing countries, the mercury concentration in tailings and water has to be determined to mitigate environmental pollution. Cold-vapor atomic absorption analysis, the most pervasive method of mercury analysis, is not suitable because tailings and water around mining facilities have extremely high mercury concentrations. On the other hand, PGA can determine high mercury concentrations in polluted samples as it has an appropriate level of sensitivity. Moreover, gold concentrations can be determined sequentially by using INAA after PGA. In conclusion, the analytical procedure established in this work using PGA and INAA is the best way to evaluate the degree of pollution and the tailing resource value. This method will significantly contribute to mitigating problems in the global environment.

  17. RIA simulation tests using driver tube for ATF cladding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cinbiz, Mahmut N.; Brown, N. R.; Lowden, R. R.

    Pellet-cladding mechanical interaction (PCMI) is a potential failure mechanism for accident-tolerant fuel (ATF) cladding candidates during a reactivity-initiated accident (RIA). This report summarizes Fiscal Year (FY) 2017 research activities that were undertaken to evaluate the PCMI-like hoop-strain-driven mechanical response of ATF cladding candidates. To achieve various RIA-like conditions, a modified-burst test (MBT) device was developed to produce different mechanical pulses. The calibration of the MBT instrument was accomplished by performing mechanical tests on unirradiated Generation-I iron-chromium-aluminum (FeCrAl) alloy samples. Shakedown tests were also conducted in both FY 2016 and FY 2017 using unirradiated hydrided ZIRLO™ tube samples. This milestone reportmore » focuses on testing of ATF materials, but the benchmark tests with hydrided ZIRLO™ tube samples are documented in a recent journal article.a For the calibration and benchmark tests, the hoop strain was monitored using strain gauges attached to the sample surface in the hoop direction. A novel digital image correlation (DIC) system composed of a single high-speed camera and an array of six mirrors was developed for the MBT instrument to better resolve the failure behavior of samples and to provide useful data for validation of high-fidelity modeling and simulation tools. The DIC system enable a 360° view of a sample’s outer surface. This feature was added to the instrument to determine the precise failure location on a sample’s surface for strain predictions. The DIC system was tested on several silicon carbide fiber/silicon carbide matrix (SiC/SiC) composite tube samples at various pressurization rates of the driver tube (which correspond to the strain rates for the samples). The hoop strains for various loading conditions were determined for the SiC/SiC composite tube samples. Future work is planned to enhance understanding of the failure behavior of the ATF cladding candidates of age-hardened FeCrAl alloys and SiC/SiC composites in detail during RIA conditions informed by the computational studies performed under the US Department of Energy Office of Nuclear Energy Advanced Fuels Campaign. The testing instrument and the new DIC system will be further developed to reach different stress-state conditions and to perform tests at elevated temperatures.« less

  18. Subsurface Formation Evaluation on Mars: Application of Methods from the Oil Patch

    NASA Astrophysics Data System (ADS)

    Passey, Q. R.

    2006-12-01

    The ability to drill 10- to 100-meter deep wellbores on Mars would allow for evaluation of shallow subsurface formations enabling the extension of current interpretations of the geologic history of this planet; moreover, subsurface access is likely to provide direct evidence to determine if water or permafrost is present. Methodologies for evaluating sedimentary rocks using drill holes and in situ sample and data acquisition are well developed here on Earth. Existing well log instruments can measure K, Th, and U from natural spectral gamma-ray emission, compressional and shear acoustic velocities, electrical resistivity and dielectric properties, bulk density (Cs-137 or Co-60 source), photoelectric absorption of gamma-rays (sensitive to the atomic number), hydrogen index from epithermal and thermal neutron scattering and capture, free hydrogen in water molecules from nuclear magnetic resonance, formation capture cross section, temperature, pressure, and elemental abundances (C, O, Si, Ca, H, Cl, Fe, S, and Gd) using 14 MeV pulsed neutron activation more elements possible with supercooled Ge detectors. Additionally, high-resolution wellbore images are possible using a variety of optical, electrical, and acoustic imaging tools. In the oil industry, these downhole measurements are integrated to describe potential hydrocarbon reservoir properties: lithology, mineralogy, porosity, depositional environment, sedimentary and structural dip, sedimentary features, fluid type (oil, gas, or water), and fluid amount (i.e., saturation). In many cases it is possible to determine the organic-carbon content of hydrocarbon source rocks from logs (if the total organic carbon content is 1 wt% or greater), and more accurate instruments likely could be developed. Since Martian boreholes will likely be drilled without using opaque drilling fluids (as generally used in terrestrial drilling), additional instruments can be used such as high resolution direct downhole imaging and other surface contact measurements (such as IR spectroscopy and x-ray fluorescence). However, such wellbores would require modification of some instruments since conventional drilling fluids often provide the coupling of the instrument sensors to the formation (e.g., sonic velocity and galvanic resistivity measurements). The ability to drill wellbores on Mars opens up new opportunities for exploration but also introduces additional technical challenges. Currently it is not known if all existing terrestrial logging instruments can be miniaturized sufficiently for a shallow Mars wellbore, but the existing well logging techniques and instruments provide a solid framework on which to build a Martian subsurface evaluation program.

  19. Measures of aggression and victimization in portuguese adolescents: Cross-cultural validation of the Revised Peer Experience Questionnaire.

    PubMed

    Queirós, Andreia N; Vagos, Paula

    2016-10-01

    The goal of this research was to develop and psychometrically evaluate the Portuguese version of the Revised Peer Experience Questionnaire, which assesses aggression, victimization and prosocial behavior. Victimization and aggression among adolescents in school settings is a growing problem, not yet fully understood or properly evaluated, particularly in Portugal. A sample of 1320 adolescents was recruited (52.7% female), with ages varying from 10 to 18 years old, attending middle and high school. Confirmatory factor analysis confirms the measurement model of the instrument's bully and victim versions, as evaluating overt, relational, and reputational aggression/victimization and providing/receiving prosocial behavior, respectively. This measurement model was invariant across schooling and gender, showed adequate internal consistency indicators, and presented evidence for construct validity in relation to other variables. Descriptive analyses indicate that boys are more aggressive in overt and relational forms and victimized through overt aggression, whereas girls are more aggressive and victimized relationally. More than any form of aggression or victimization, boys and girls revealed higher values for engaging in and receiving prosocial behavior. These results suggest that this instrument is a reliable, valid, and structurally sound measure of aggression, victimization and prosocial behavior in this Portuguese school-based community sample. Hence, its use may assist researchers in gaining a better understanding of adolescent aggression and victimization. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  20. Healthcare teams as complex adaptive systems: Focus on interpersonal interaction.

    PubMed

    Pype, Peter; Krystallidou, Demi; Deveugele, Myriam; Mertens, Fien; Rubinelli, Sara; Devisch, Ignaas

    2017-11-01

    The aim of this study is to test the feasibility of a tool to objectify the functioning of healthcare teams operating in the complexity zone, and to evaluate its usefulness in identifying areas for team quality improvement. We distributed The Complex Adaptive Leadership (CAL™) Organisational Capability Questionnaire (OCQ) to all members of one palliative care team (n=15) and to palliative care physicians in Flanders, Belgium (n=15). Group discussions were held on feasibility aspects and on the low scoring topics. Data was analysed calculating descriptive statistics (sum score, mean and standard deviation). The one sample T-Test was used to detect differences within each group. Both groups of participants reached mean scores ranging from good to excellent. The one sample T test showed statistically significant differences between participants' sum scores within each group (p<0,001). Group discussion led to suggestions for quality improvement e.g. enhanced feedback strategies between team members. The questionnaire used in our study shows to be a feasible and useful instrument for the evaluation of the palliative care teams' day-to-day operations and to identify areas for quality improvement. The CAL™OCQ is a promising instrument to evaluate any healthcare team functioning. A group discussion on the questionnaire scores can serve as a starting point to identify targets for quality improvement initiatives. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Evaluation of the Iconic Pain Assessment Tool by a heterogeneous group of people in pain

    PubMed Central

    Lalloo, Chitra; Henry, James L

    2011-01-01

    The Iconic Pain Assessment Tool (IPAT) is a novel web-based instrument for the self-report of pain quality, intensity and location in the form of a permanent diary. Originally designed for people with central poststroke pain, the tool is being adapted for a larger, more diverse patient population. The present study aimed to collect evaluative feedback on the IPAT from a heterogeneous sample of individuals with chronic pain. The specific study aims were to evaluate participant comfort with the tool including enjoyment, ease of use and comfort with the electronic medium; to assess perceived value of the tool for communicating pain quality, intensity and location; to gauge participant intent to share their pain diaries with others and use the tool on a regular basis to track their pain over time; to assess the perceived descriptiveness of current IPAT icons and the numerical rating scale; and to identify strengths and weaknesses of the tool to refine the existing prototype. Written and verbal feedback from individuals with a variety of chronic pain conditions (n=23) were collected in the context of these objectives. Overall, the IPAT was positively endorsed by this heterogeneous sample of people in pain. The authors concluded that the IPAT is a user-friendly instrument that has the potential to help people express, document and share their personal experience with chronic pain. PMID:21369536

  2. The development and evaluation of airborne in situ N2O and CH4 sampling using a quantum cascade laser absorption spectrometer (QCLAS)

    NASA Astrophysics Data System (ADS)

    Pitt, J. R.; Le Breton, M.; Allen, G.; Percival, C. J.; Gallagher, M. W.; Bauguitte, S. J.-B.; O'Shea, S. J.; Muller, J. B. A.; Zahniser, M. S.; Pyle, J.; Palmer, P. I.

    2016-01-01

    Spectroscopic measurements of atmospheric N2O and CH4 mole fractions were made on board the FAAM (Facility for Airborne Atmospheric Measurements) large atmospheric research aircraft. We present details of the mid-infrared quantum cascade laser absorption spectrometer (QCLAS, Aerodyne Research Inc., USA) employed, including its configuration for airborne sampling, and evaluate its performance over 17 flights conducted during summer 2014. Two different methods of correcting for the influence of water vapour on the spectroscopic retrievals are compared and evaluated. A new in-flight calibration procedure to account for the observed sensitivity of the instrument to ambient pressure changes is described, and its impact on instrument performance is assessed. Test flight data linking this sensitivity to changes in cabin pressure are presented. Total 1σ uncertainties of 2.47 ppb for CH4 and 0.54 ppb for N2O are derived. We report a mean difference in 1 Hz CH4 mole fraction of 2.05 ppb (1σ = 5.85 ppb) between in-flight measurements made using the QCLAS and simultaneous measurements using a previously characterised Fast Greenhouse Gas Analyser (FGGA, Los Gatos Research, USA). Finally, a potential case study for the estimation of a regional N2O flux using a mass balance technique is identified, and the method for calculating such an estimate is outlined.

  3. The development and evaluation of airborne in situ N2O and CH4 sampling using a Quantum Cascade Laser Absorption Spectrometer (QCLAS)

    NASA Astrophysics Data System (ADS)

    Pitt, J. R.; Le Breton, M.; Allen, G.; Percival, C. J.; Gallagher, M. W.; Bauguitte, S. J.-B.; O'Shea, S. J.; Muller, J. B. A.; Zahniser, M. S.; Pyle, J.; Palmer, P. I.

    2015-08-01

    Spectroscopic measurements of atmospheric N2O and CH4 mole fractions were made on board the FAAM (Facility for Airborne Atmospheric Measurements) large Atmospheric Research Aircraft. We present details of the mid-IR Aerodyne Research Inc. Quantum Cascade Laser Absorption Spectrometer (QCLAS) employed, including its configuration for airborne sampling, and evaluate its performance over 17 flights conducted during summer 2014. Two different methods of correcting for the influence of water vapour on the spectroscopic retrievals are compared and evaluated. A new in-flight calibration procedure to account for the observed sensitivity of the instrument to ambient pressure changes is described, and its impact on instrument performance is assessed. Test flight data linking this sensitivity to changes in cabin pressure is presented. Total 1σ uncertainties of 1.81 ppb for CH4 and 0.35 ppb for N2O are derived. We report a mean difference in 1 Hz CH4 mole fraction of 2.05 ppb (1σ = 5.85 ppb) between in-flight measurements made using the QCLAS and simultaneous measurements using a previously characterised Los Gatos Research Fast Greenhouse Gas Analyser (FGGA). Finally, a potential case study for the estimation of a regional N2O flux using a mass balance technique is identified, and the method for calculating such an estimate is outlined.

  4. Improved methods for signal processing in measurements of mercury by Tekran® 2537A and 2537B instruments

    NASA Astrophysics Data System (ADS)

    Ambrose, Jesse L.

    2017-12-01

    Atmospheric Hg measurements are commonly carried out using Tekran® Instruments Corporation's model 2537 Hg vapor analyzers, which employ gold amalgamation preconcentration sampling and detection by thermal desorption (TD) and atomic fluorescence spectrometry (AFS). A generally overlooked and poorly characterized source of analytical uncertainty in those measurements is the method by which the raw Hg atomic fluorescence (AF) signal is processed. Here I describe new software-based methods for processing the raw signal from the Tekran® 2537 instruments, and I evaluate the performances of those methods together with the standard Tekran® internal signal processing method. For test datasets from two Tekran® instruments (one 2537A and one 2537B), I estimate that signal processing uncertainties in Hg loadings determined with the Tekran® method are within ±[1 % + 1.2 pg] and ±[6 % + 0.21 pg], respectively. I demonstrate that the Tekran® method can produce significant low biases (≥ 5 %) not only at low Hg sample loadings (< 5 pg) but also at tropospheric background concentrations of gaseous elemental mercury (GEM) and total mercury (THg) (˜ 1 to 2 ng m-3) under typical operating conditions (sample loadings of 5-10 pg). Signal processing uncertainties associated with the Tekran® method can therefore represent a significant unaccounted for addition to the overall ˜ 10 to 15 % uncertainty previously estimated for Tekran®-based GEM and THg measurements. Signal processing bias can also add significantly to uncertainties in Tekran®-based gaseous oxidized mercury (GOM) and particle-bound mercury (PBM) measurements, which often derive from Hg sample loadings < 5 pg. In comparison, estimated signal processing uncertainties associated with the new methods described herein are low, ranging from within ±0.053 pg, when the Hg thermal desorption peaks are defined manually, to within ±[2 % + 0.080 pg] when peak definition is automated. Mercury limits of detection (LODs) decrease by 31 to 88 % when the new methods are used in place of the Tekran® method. I recommend that signal processing uncertainties be quantified in future applications of the Tekran® 2537 instruments.

  5. A comparative evaluation of the efficacy of manual, magnetostrictive and piezoelectric ultrasonic instruments - an in vitro profilometric and SEM study

    PubMed Central

    SINGH, Sumita; UPPOOR, Ashita; NAYAK, Dilip

    2012-01-01

    Objectives The debridement of diseased root surface is usually performed by mechanical scaling and root planing using manual and power driven instruments. Many new designs in ultrasonic powered scaling tips have been developed. However, their effectiveness as compared to manual curettes has always been debatable. Thus, the objective of this in vitro study was to comparatively evaluate the efficacy of manual, magnetostrictive and piezoelectric ultrasonic instrumentation on periodontally involved extracted teeth using profilometer and scanning electron microscope (SEM). Material and Methods 30 periodontally involved extracted human teeth were divided into 3 groups. The teeth were instrumented with hand and ultrasonic instruments resembling clinical application. In Group A all teeth were scaled with a new universal hand curette (Hu Friedy Gracey After Five Vision curette; Hu Friedy, Chicago, USA). In Group B CavitronTM FSI - SLITM ultrasonic device with focused spray slimline inserts (Dentsply International Inc., York, PA, USA) were used. In Group C teeth were scaled with an EMS piezoelectric ultrasonic device with prototype modified PS inserts. The surfaces were analyzed by a Precision profilometer to measure the surface roughness (Ra value in µm) consecutively before and after the instrumentation. The samples were examined under SEM at magnifications ranging from 17x to 300x and 600x. Results The mean Ra values (µm) before and after instrumentation in all the three groups A, B and C were tabulated. After statistically analyzing the data, no significant difference was observed in the three experimental groups. Though there was a decrease in the percentage reduction of Ra values consecutively from group A to C. Conclusion Within the limits of the present study, given that the manual, magnetostrictive and piezoelectric ultrasonic instruments produce the same surface roughness, it can be concluded that their efficacy for creating a biologically compatible surface of periodontally diseased teeth is similar. PMID:22437673

  6. Comparison of three sampling instruments, Cytobrush, Curette and OralCDx, for liquid-based cytology of the oral mucosa.

    PubMed

    Reboiras-López, M D; Pérez-Sayáns, M; Somoza-Martín, J M; Antúnez-López, J R; Gándara-Vila, P; Gayoso-Diz, P; Gándara-Rey, J M; García-García, A

    2012-01-01

    Exfoliative cytology of the oral cavity is a simple and noninvasive technique that permits the study of epithelial cells. Liquid-based cytology is an auxiliary diagnostic tool for improving the specificity and sensitivity of conventional cytology. The objective of our study was to compare the quality of normal oral mucosa cytology samples obtained using three different instruments, Cytobrush®, dermatological curette and Oral CDx® for liquid-based cytology. One hundred four cytological samples of oral cavity were analyzed. Samples were obtained from healthy volunteer subjects using all three instruments. The clinical and demographic variables were age, sex and smoking habits. We analyzed cellularity, quality of the preparation and types of cells in the samples. All preparations showed appropriate preparation quality. In all smears analyzed, cells were distributed uniformly and showed no mucus, bleeding, inflammatory exudate or artifacts. We found no correlation between the average number of cells and the type of instrument. The samples generally consisted of two types of cells: superficial and intermediate. No differences were found among the cytological preparations of these three instruments. We did not observe basal cells in any of the samples analyzed.

  7. Initial evaluation of airborne water vapour measurements by the IAGOS-GHG CRDS system

    NASA Astrophysics Data System (ADS)

    Filges, Annette; Gerbig, Christoph; Smit, Herman G. J.; Krämer, Martina; Spelten, Nicole

    2013-04-01

    Accurate and reliable airborne measurements of water vapour are still a challenge. Presently, no airborne humidity sensor exists that covers the entire range of water vapour content between the surface and the upper troposphere/lower stratosphere (UT/LS) region with sufficient accuracy and time resolution. Nevertheless , these data are a pre-requisite to study the underlying processes in the chemistry and physics of the atmosphere. The DENCHAR project (Development and Evaluation of Novel Compact Hygrometer for Airborne Research) addresses this deficit by developing and characterizing novel or improved compact airborne hygrometers for different airborne applications within EUFAR (European Facility for Airborne Research). As part of the DENCHAR inter-comparison campaign in Hohn (Germany), 23 May - 1 June 2011, a commercial gas analyzer (G2401-m, Picarro Inc.,US), based on cavity ring-down spectroscopy (CRDS), was installed on a Learjet to measure water vapour, CO2, CH4 and CO. The CRDS components are identical to those chosen for integration aboard commercial airliner within IAGOS (In-service Aircraft for a Global Observing System). Thus the campaign allowed for the initial assessment validation of the long-term IAGOS H2O measurements by CRDS against reference instruments with a long performance record (FISH, the Fast In-situ Stratospheric Hygrometer, and CR2 frostpoint hygrometer, both research centre Juelich). The inlet system, a one meter long 1/8" FEP-tube connected to a Rosemount TAT housing (model 102BX, deiced) installed on a window plate of the aircraft, was designed to eliminate sampling of larger aerosols, ice particles, and water droplets, and provides about 90% of ram-pressure. In combination with a lowered sample flow of 0.1 slpm (corresponding to a 4 second response time), this ensured a fully controlled sample pressure in the cavity of 140 torr throughout an aircraft altitude operating range up to 12.5 km without the need of an upstream sampling pump. This setup ensures full compatibility with the future deployment of the analyser within IAGOS. For the initial water calibration of the instrument, a calibration of a similar instrument performed at MPI-BGC Jena against a dew point mirror (Dewmet, Michell instruments Ltd., UK) in the range from 0.7 to 3.0% was transferred to all subsequently manufactured CRDS instruments by Picarro. During the campaign the analyzer was compared against a reference frost point hygrometer, which is also used for calibration of the reference instrument FISH. The dew point mirror calibration was within 0.7 % of the FISH calibrator, but showed an offset of 14.45 ppm, which is consistent with the H2O content of dry tank air and diffusion effects through the inlet line (FEP). Furthermore, a new independent calibration method, based on the dilution effect of water vapour on CO2, was tested. It showed a 9 % low bias compared to the dew point mirror calibration. Comparison of the in-flight data against the reference systems showed that the analyzer is reliable and has a good long-term stability. Flight data from the DENCHAR campaign suggest a conservative precision estimate for measurements made at 0.4 Hz of 4 ppm for H2O < 100 ppm, and 4 % (relative) for H2O > 100 ppm. Accuracy at mixing ratios below 50 ppm was difficult to assess, as the reference instruments suffered from lack of stability. We present the results of the campaign flights and comparison with the reference instruments. The different calibration methods will be discussed.

  8. Patients' perceptions of palliative care: adaptation of the Quality from the Patient's Perspective instrument for use in palliative care, and description of patients' perceptions of care received.

    PubMed

    Sandsdalen, Tuva; Rystedt, Ingrid; Grøndahl, Vigdis Abrahamsen; Hov, Reidun; Høye, Sevald; Wilde-Larsson, Bodil

    2015-11-02

    Instruments specific to palliative care tend to measure care quality from relative perspectives or have insufficient theoretical foundation. The instrument Quality from the Patient's Perspective (QPP) is based on a model for care quality derived from patients' perceptions of care, although it has not been psychometrically evaluated for use in palliative care. The aim of this study was to adapt the QPP for use in palliative care contexts, and to describe patients' perceptions of the care quality in terms of the subjective importance of the care aspects and the perceptions of the care received. A cross-sectional study was conducted between November 2013 and December 2014 which included 191 patients (73% response rate) in late palliative phase at hospice inpatient units, hospice day-care units, wards in nursing homes that specialized in palliative care and homecare districts, all in Norway. An explorative factor analysis using principal component analysis, including data from 184 patients, was performed for psychometric evaluation. Internal consistency was assessed by Cronbach's alpha and paired t-tests were used to describe patients' perceptions of their care. The QPP instrument was adapted for palliative care in four steps: (1) selecting items from the QPP, (2) modifying items and (3) constructing new items to the palliative care setting, and (4) a pilot evaluation. QPP instrument specific to palliative care (QPP-PC) consists of 51 items and 12 factors with an eigenvalue ≥1.0, and showed a stable factor solution that explained 68.25% of the total variance. The reliability coefficients were acceptable for most factors (0.79-0.96). Patients scored most aspects of care related to both subjective importance and actual care received as high. Areas for improvement were symptom relief, participation, continuity, and planning and cooperation. The QPP-PC is based on a theoretical model of quality of care, and has its roots in patients' perspectives. The instrument was developed and psychometrically evaluated in a sample of Norwegian patients with various diagnoses receiving palliative care in different care contexts. The evaluation of the QPP-PC shows promising results, although it needs to be further validated and tested in other contexts and countries.

  9. Quality Evaluation Scores are no more Reliable than Gestalt in Evaluating the Quality of Emergency Medicine Blogs: A METRIQ Study.

    PubMed

    Thoma, Brent; Sebok-Syer, Stefanie S; Colmers-Gray, Isabelle; Sherbino, Jonathan; Ankel, Felix; Trueger, N Seth; Grock, Andrew; Siemens, Marshall; Paddock, Michael; Purdy, Eve; Kenneth Milne, William; Chan, Teresa M

    2018-01-30

    Construct: We investigated the quality of emergency medicine (EM) blogs as educational resources. Online medical education resources such as blogs are increasingly used by EM trainees and clinicians. However, quality evaluations of these resources using gestalt are unreliable. We investigated the reliability of two previously derived quality evaluation instruments for blogs. Sixty English-language EM websites that published clinically oriented blog posts between January 1 and February 24, 2016, were identified. A random number generator selected 10 websites, and the 2 most recent clinically oriented blog posts from each site were evaluated using gestalt, the Academic Life in Emergency Medicine (ALiEM) Approved Instructional Resources (AIR) score, and the Medical Education Translational Resources: Impact and Quality (METRIQ-8) score, by a sample of medical students, EM residents, and EM attendings. Each rater evaluated all 20 blog posts with gestalt and 15 of the 20 blog posts with the ALiEM AIR and METRIQ-8 scores. Pearson's correlations were calculated between the average scores for each metric. Single-measure intraclass correlation coefficients (ICCs) evaluated the reliability of each instrument. Our study included 121 medical students, 88 EM residents, and 100 EM attendings who completed ratings. The average gestalt rating of each blog post correlated strongly with the average scores for ALiEM AIR (r = .94) and METRIQ-8 (r = .91). Single-measure ICCs were fair for gestalt (0.37, IQR 0.25-0.56), ALiEM AIR (0.41, IQR 0.29-0.60) and METRIQ-8 (0.40, IQR 0.28-0.59). The average scores of each blog post correlated strongly with gestalt ratings. However, neither ALiEM AIR nor METRIQ-8 showed higher reliability than gestalt. Improved reliability may be possible through rater training and instrument refinement.

  10. A combination dielectric and acoustic laboratory instrument for petrophysics

    NASA Astrophysics Data System (ADS)

    Josh, Matthew

    2017-12-01

    Laboratory testing of rock samples is the primary method for establishing the physics models which relate the rock properties (i.e. porosity, fluid permeability, pore-fluid and saturation) essential to evaluating a hydrocarbon reservoir, to the physical properties (resistivity, nuclear magnetic resonance, dielectric permittivity and acoustic properties) which can be measured with borehole logging instrumentation. Rock samples usually require machining to produce a suitable geometry for each test as well as specific sample preparation, e.g. multiple levels of saturation and chemical treatments, and this leads to discrepancies in the condition of the sample between different tests. Ideally, multiphysics testing should occur on one sample simultaneously so that useful correlations between data sets can be more firmly established. The world’s first dielectric and acoustic combination cell has been developed at CSIRO, so that a sample may be machined and prepared, then measured to determine the dielectric and acoustic properties simultaneously before atmospheric conditions in the laboratory affect the level of hydration in the sample. The dielectric measurement is performed using a conventional three-terminal parallel plate capacitor which can operate from 40 Hz up to 110 MHz, with modified electrodes incorporating a 4 MHz P-wave piezo crystal. Approximately 10 (acoustic P-) wavelengths interact with a typical (10 mm thick) sample so that the user may reliably ‘pick’ the P-wave arrival times with acceptable resolution. Experimental evidence indicates that the instrument is able to resolve 0.25 mm thickness in a Teflon sample test piece. For a number of engineering materials including Teflon and glass and also for a geological samples (Donnybrook sandstone from Western Australia) there is a perfectly linear relationship between both capacitance and P-wave arrival time with sample thickness. Donnybrook sandstone has a consistently linear increase in dielectric permittivity and P-wave velocity with saturation consistent with the Gassmann-Hill prediction. Both the dielectric permittivity and P-wave velocity are faster parallel to the bedding plane than orthogonal to the bedding plane in a shale from the Cooper Basin, Australia.

  11. External evaluation of the Dimension Vista 1500® intelligent lab system.

    PubMed

    Bruneel, Arnaud; Dehoux, Monique; Barnier, Anne; Boutten, Anne

    2012-09-01

    Dimension Vista® analyzer combines four technologies (photometry, nephelometry, V-LYTE® integrated multisensor potentiometry, and LOCI® chemiluminescence) into one high-throughput system. We assessed analytical performance of assays routinely performed in our emergency laboratory according to the VALTEC protocol, and practicability. Precision was good for most parameters. Analytical domain was large and suitable for undiluted analysis in most clinical settings encountered in our hospital. Data were comparable and correlated to our routine analyzers (Roche Modular DP®, Abbott AXSYM®, Siemens Dimension® RxL, and BN ProSpec®). Performance of nephelometric and LOCI modules was excellent. Functional sensitivity of high-sensitivity C-reactive protein and cardiac troponin I were 0.165 mg/l and 0.03 ng/ml, respectively (coefficient of variation; CV < 10%). The influence of interfering substances (i.e., hemoglobin, bilirubin, or lipids) was moderate, and Dimension Vista® specifically alerted for interference according to HIL (hemolysis, icterus, lipemia) indices. Good instrument performance and full functionality (no reagent or sample carryover in the conditions evaluated, effective sample-volume detection, and clot detection) were confirmed. Simulated routine testing demonstrated excellent practicability, throughput, ease of use of software and security. Performance and practicability of Dimension Vista® are highly suitable for both routine and emergency use. Since no volume detection and thus no warning is available on limited sample racks, pediatric samples require special caution to the Siemens protocol to be analyzed in secured conditions. Our experience in routine practice is also discussed, i.e., the impact of daily workload, "manual" steps resulting from dilutions and pediatric samples, maintenances, flex hydration on instrument's performance on throughput and turnaround time. © 2012 Wiley Periodicals, Inc.

  12. Repeatability and Reproducibility in Proteomic Identifications by Liquid Chromatography—Tandem Mass Spectrometry

    PubMed Central

    Tabb, David L.; Vega-Montoto, Lorenzo; Rudnick, Paul A.; Variyath, Asokan Mulayath; Ham, Amy-Joan L.; Bunk, David M.; Kilpatrick, Lisa E.; Billheimer, Dean D.; Blackman, Ronald K.; Cardasis, Helene L.; Carr, Steven A.; Clauser, Karl R.; Jaffe, Jacob D.; Kowalski, Kevin A.; Neubert, Thomas A.; Regnier, Fred E.; Schilling, Birgit; Tegeler, Tony J.; Wang, Mu; Wang, Pei; Whiteaker, Jeffrey R.; Zimmerman, Lisa J.; Fisher, Susan J.; Gibson, Bradford W.; Kinsinger, Christopher R.; Mesri, Mehdi; Rodriguez, Henry; Stein, Steven E.; Tempst, Paul; Paulovich, Amanda G.; Liebler, Daniel C.; Spiegelman, Cliff

    2009-01-01

    The complexity of proteomic instrumentation for LC-MS/MS introduces many possible sources of variability. Data-dependent sampling of peptides constitutes a stochastic element at the heart of discovery proteomics. Although this variation impacts the identification of peptides, proteomic identifications are far from completely random. In this study, we analyzed interlaboratory data sets from the NCI Clinical Proteomic Technology Assessment for Cancer to examine repeatability and reproducibility in peptide and protein identifications. Included data spanned 144 LC-MS/MS experiments on four Thermo LTQ and four Orbitrap instruments. Samples included yeast lysate, the NCI-20 defined dynamic range protein mix, and the Sigma UPS 1 defined equimolar protein mix. Some of our findings reinforced conventional wisdom, such as repeatability and reproducibility being higher for proteins than for peptides. Most lessons from the data, however, were more subtle. Orbitraps proved capable of higher repeatability and reproducibility, but aberrant performance occasionally erased these gains. Even the simplest protein digestions yielded more peptide ions than LC-MS/MS could identify during a single experiment. We observed that peptide lists from pairs of technical replicates overlapped by 35–60%, giving a range for peptide-level repeatability in these experiments. Sample complexity did not appear to affect peptide identification repeatability, even as numbers of identified spectra changed by an order of magnitude. Statistical analysis of protein spectral counts revealed greater stability across technical replicates for Orbitraps, making them superior to LTQ instruments for biomarker candidate discovery. The most repeatable peptides were those corresponding to conventional tryptic cleavage sites, those that produced intense MS signals, and those that resulted from proteins generating many distinct peptides. Reproducibility among different instruments of the same type lagged behind repeatability of technical replicates on a single instrument by several percent. These findings reinforce the importance of evaluating repeatability as a fundamental characteristic of analytical technologies. PMID:19921851

  13. Analytical improvements of hybrid LC-MS/MS techniques for the efficient evaluation of emerging contaminants in river waters: a case study of the Henares River (Madrid, Spain).

    PubMed

    Pérez-Parada, Andrés; Gómez-Ramos, María del Mar; Martínez Bueno, María Jesús; Uclés, Samanta; Uclés, Ana; Fernández-Alba, Amadeo R

    2012-02-01

    Instrumental capabilities and software tools of modern hybrid mass spectrometry (MS) instruments such as high-resolution mass spectrometry (HRMS), quadrupole time-of-flight (QTOF), and quadrupole linear ion trap (QLIT) were experimentally investigated for the study of emerging contaminants in Henares River water samples. Automated screening and confirmatory capabilities of QTOF working in full-scan MS and tandem MS (MS/MS) were explored when dealing with real samples. Investigations on the effect of sensitivity and resolution power influence on mass accuracy were studied for the correct assignment of the amoxicillin transformation product 5(R) amoxicillin-diketopiperazine-2',5' as an example of a nontarget compound. On the other hand, a comparison of quantitative and qualitative strategies based on direct injection analysis and off-line solid-phase extraction sample treatment were assayed using two different QLIT instruments for a selected group of emerging contaminants when operating in selected reaction monitoring (SRM) and information-dependent acquisition (IDA) modes. Software-aided screening usually needs a further confirmatory step. Resolving power and MS/MS feature of QTOF showed to confirm/reject most findings in river water, although sensitivity-related limitations are usually found. Superior sensitivity of modern QLIT-MS/MS offered the possibility of direct injection analysis for proper quantitative study of a variety of contaminants, while it simultaneously reduced the matrix effect and increased the reliability of the results. Confirmation of ethylamphetamine, which lacks on a second SRM transition, was accomplished by using the IDA feature. Hybrid MS instruments equipped with high resolution and high sensitivity contributes to enlarge the scope of targeted analytes in river waters. However, in the tested instruments, there is a margin of improvement principally in required sensitivity and data treatment software tools devoted to reliable confirmation and improved automated data processing.

  14. Radioactive sample effects on EDXRF spectra

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Worley, Christopher G

    2008-01-01

    Energy dispersive X-ray fluorescence (EDXRF) is a rapid, straightforward method to determine sample elemental composition. A spectrum can be collected in a few minutes or less, and elemental content can be determined easily if there is adequate energy resolution. Radioactive alpha emitters, however, emit X-rays during the alpha decay process that complicate spectral interpretation. This is particularly noticeable when using a portable instrument where the detector is located in close proximity to the instrument analysis window held against the sample. A portable EDXRF instrument was used to collect spectra from specimens containing plutonium-239 (a moderate alpha emitter) and americium-241 (amore » heavy alpha emitter). These specimens were then analyzed with a wavelength dispersive XRF (WDXRF) instrument to demonstrate the differences to which sample radiation-induced X-ray emission affects the detectors on these two types of XRF instruments.« less

  15. A device for high-throughput monitoring of degradation in soft tissue samples.

    PubMed

    Tzeranis, D S; Panagiotopoulos, I; Gkouma, S; Kanakaris, G; Georgiou, N; Vaindirlis, N; Vasileiou, G; Neidlin, M; Gkousioudi, A; Spitas, V; Macheras, G A; Alexopoulos, L G

    2018-06-06

    This work describes the design and validation of a novel device, the High-Throughput Degradation Monitoring Device (HDD), for monitoring the degradation of 24 soft tissue samples over incubation periods of several days inside a cell culture incubator. The device quantifies sample degradation by monitoring its deformation induced by a static gravity load. Initial instrument design and experimental protocol development focused on quantifying cartilage degeneration. Characterization of measurement errors, caused mainly by thermal transients and by translating the instrument sensor, demonstrated that HDD can quantify sample degradation with <6 μm precision and <10 μm temperature-induced errors. HDD capabilities were evaluated in a pilot study that monitored the degradation of fresh ex vivo human cartilage samples by collagenase solutions over three days. HDD could robustly resolve the effects of collagenase concentration as small as 0.5 mg/ml. Careful sample preparation resulted in measurements that did not suffer from donor-to-donor variation (coefficient of variance <70%). Due to its unique combination of sample throughput, measurement precision, temporal sampling and experimental versality, HDD provides a novel biomechanics-based experimental platform for quantifying the effects of proteins (cytokines, growth factors, enzymes, antibodies) or small molecules on the degradation of soft tissues or tissue engineering constructs. Thereby, HDD can complement established tools and in vitro models in important applications including drug screening and biomaterial development. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Derivative financial instruments and nonprofit health care providers.

    PubMed

    Stewart, Louis J; Owhoso, Vincent

    2004-01-01

    This article examines the extent of derivative financial instrument use among US nonprofit health systems and the impact of these financial instruments on their cash flows, reported operating results, and financial risks. Our examination is conducted through a case study of New Jersey hospitals and health systems. We review the existing literature on interest rate derivative instruments and US hospitals and health systems. This literature describes the design of these derivative financial instruments and the theoretical benefits of their use by large health care provider organizations. Our contribution to the literature is to provide an empirical evaluation of derivative financial instruments usage among a geographically limited sample of US nonprofit health systems. We reviewed the audited financial statements of the 49 community hospitals and multi-hospital health systems operating in the state of New Jersey. We found that 8 percent of New Jersey's nonprofit health providers utilized interest rate derivatives with an aggregate principle value of $229 million. These derivative users combine interest rate swaps and caps to lower the effective interest costs of their long-term debt while limiting their exposure to future interest rate increases. In addition, while derivative assets and liabilities have an immaterial balance sheet impact, derivative related gains and losses are a material component of their reported operating results. We also found that derivative usage among these four health systems was responsible for generating positive cash flows in the range of 1 percent to 2 percent of their total 2001 cash flows from operations. As a result of our admittedly limited samples we conclude that interest rate swaps and caps are effective risk management tools. However, we also found that while these derivative financial instruments are useful hedges against the risks of issuing long-term financing instruments, they also expose derivative users to credit, contract termination and interest rate volatility risks. In conclusion, we find that these financial instruments can also generate negative as well as positive cash flows and have both a positive and negative impact on reported operating results.

  17. A compact, fast ozone UV photometer and sampling inlet for research aircraft

    NASA Astrophysics Data System (ADS)

    Gao, R. S.; Ballard, J.; Watts, L. A.; Thornberry, T. D.; Ciciora, S. J.; McLaughlin, R. J.; Fahey, D. W.

    2012-05-01

    In situ measurements of atmospheric ozone (O3) are performed routinely from many research aircraft platforms. The most common technique depends on the strong absorption of ultraviolet (UV) light by ozone. As atmospheric science advances to the widespread use of unmanned aircraft systems (UASs), there is an increasing requirement for minimizing instrument space, weight, and power while maintaining instrument accuracy, precision and time response. The design and use of a new, dual-beam, polarized, UV photometer instrument for in situ O3 measurements is described. The instrument has a fast sampling rate (2 Hz), high accuracy (3%), and precision (1.1 × 1010 O3 molecules cm-3). The size (36 l), weight (18 kg), and power (50-200 W) make the instrument suitable for many UAS and other airborne platforms. Inlet and exhaust configurations are also described for ambient sampling in the troposphere and lower stratosphere (1000-50 mb) that optimize the sample flow rate to increase time response while minimizing loss of precision due to induced turbulence in the sample cell. In-flight and laboratory intercomparisons with existing O3 instruments show that measurement accuracy is maintained in flight.

  18. The Psychometric Evaluation of the Connor-Davidson Resilience Scale Using a Chinese Military Sample

    PubMed Central

    Xie, Yuanjun; Peng, Li; Zuo, Xin; Li, Min

    2016-01-01

    This study examined the psychometric properties of the Connor-Davidson Resilience Scale (CD-RISC) with a Chinese military population with the aim of finding a suitable instrument to quantify resilience in Chinese military service members. The confirmatory factor analysis results did not support the factorial structure of the original or the Chinese community version of the CD-RISC, but the exploratory factor analysis results revealed a three-factor model (composed of Competency, Toughness, and Adaptability) that seemed to fit. Moreover, the repeat confirmatory factory analysis replicated the three-factor model. Additionally, the CD-RISC with a Chinese military sample exhibited appropriate psychometric properties, including internal consistency, test-retest reliability, and structural and concurrent validity. The revised CD-RISC with a Chinese military sample provides insight into the resilience measurement framework and could be a reliable and valid measurement for evaluating resilience in a Chinese military population. PMID:26859484

  19. ESTIMATION OF DIFFUSION LOSSES WHEN SAMPLING DIESEL AEROSOL: A QUALITY ASSURANCE MEASURE

    EPA Science Inventory

    A fundamental component of the QA work for the assessment of instruments and sampling system performance was the investigation of particle losses in sampling lines. Along the aerosol sample pathway from its source to the collection media or measuring instrument, some nano-size p...

  20. An inexpensive instrument for measuring wave exposure and water velocity

    USGS Publications Warehouse

    Figurski, J.D.; Malone, D.; Lacy, J.R.; Denny, M.

    2011-01-01

    Ocean waves drive a wide variety of nearshore physical processes, structuring entire ecosystems through their direct and indirect effects on the settlement, behavior, and survivorship of marine organisms. However, wave exposure remains difficult and expensive to measure. Here, we report on an inexpensive and easily constructed instrument for measuring wave-induced water velocities. The underwater relative swell kinetics instrument (URSKI) is a subsurface float tethered by a short (<1 m) line to the seafloor. Contained within the float is an accelerometer that records the tilt of the float in response to passing waves. During two field trials totaling 358 h, we confirmed the accuracy and precision of URSKI measurements through comparison to velocities measured by an in situ acoustic Doppler velocimeter and those predicted by a standard swell model, and we evaluated how the dimensions of the devices, its buoyancy, and sampling frequency can be modified for use in a variety of environments.

  1. How is the instrumental color of meat measured?

    PubMed

    Tapp, W N; Yancey, J W S; Apple, J K

    2011-09-01

    Peer-reviewed journal articles (n=1068) were used to gather instrumental color measurement information in meat science research. The majority of articles, published in 10 peer-reviewed journals, originated from European countries (44.8%) and North America (38.5%). The predominant species was pork (44.2%), and most researchers used Minolta (60.0%) over Hunter (31.6%) colorimeters. Much of the research was done using illuminant D65 (32.3%); nevertheless, almost half (48.9%) of the articles did not report the illuminant. Moreover, a majority of the articles did not report aperture size (73.6%) or the number of readings per sample (52.4%). Many factors influence meat color, and a considerable proportion of the peer-reviewed, published research articles failed to include information necessary to replicate and/or interpret instrumental color results; therefore, a standardized set of minimum reportable parameters for meat color evaluation should be identified. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. A simple, objective analysis scheme for scatterometer data. [Seasat A satellite observation of wind over ocean

    NASA Technical Reports Server (NTRS)

    Levy, G.; Brown, R. A.

    1986-01-01

    A simple economical objective analysis scheme is devised and tested on real scatterometer data. It is designed to treat dense data such as those of the Seasat A Satellite Scatterometer (SASS) for individual or multiple passes, and preserves subsynoptic scale features. Errors are evaluated with the aid of sampling ('bootstrap') statistical methods. In addition, sensitivity tests have been performed which establish qualitative confidence in calculated fields of divergence and vorticity. The SASS wind algorithm could be improved; however, the data at this point are limited by instrument errors rather than analysis errors. The analysis error is typically negligible in comparison with the instrument error, but amounts to 30 percent of the instrument error in areas of strong wind shear. The scheme is very economical, and thus suitable for large volumes of dense data such as SASS data.

  3. Does laboratory automation for the preanalytical phase improve data quality?

    PubMed

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Danese, Elisa; Montagnana, Martina; Brocco, Giorgio; Voi, Monica; Picheth, Geraldo; Guidi, Gian Cesare

    2013-10-01

    Our aim was to evaluate whether automation for the preanalytical phase improves data quality. Blood from 100 volunteers was collected into two vacuum tubes. One sample from each volunteer was respectively assigned to (G1) traditional processing, starting with centrifugation at 1200 g for 10 min, and (G2) the MODULAR PRE-ANALYTICALS EVO-MPA system. The routine clinical chemistry tests were performed in duplicate on the same instrument Cobas 6000 module. G1 samples were uncapped manually and immediately placed into the instrument. G2 samples were directly fed from the MPA system to the instrument without further staff intervention. At the end, (1) the G1 samples were stored for 6 h at 4 °C as prescribed in our accredited laboratory and (2) the G2 samples were stored for 6 h in the MPA output buffer. Results from G1 and G2, before and after storage, were compared. Significant increases were observed in G1 compared with G2 samples as follows: (1) before storage for alkaline phosphatase (ALP), lactate dehydrogenase (LDH), phosphate (P), magnesium (MG), iron (FE), and hemolysis index and (2) after storage for total cholesterol (COL), triglycerides (TG), total protein (TP), albumin (ALB), blood urea nitrogen (BUN), creatinine (CRE), uric acid (UA), ALP, pancreatic amylase, aspartate aminotransferase (AST), alanine aminotransferase (ALT), g-glutamyltransferase (GGT), LDH, creatine kinase (CK), calcium (CA), FE, sodium (NA), potassium (K), and hemolysis index. Moreover, significant increases were observed in (3) G1-after versus G1-before storage samples for COL, high-density lipoprotein cholesterol, TG, TP, ALB, BUN, CRE, UA, AST, ALT, GGT, LDH, P, CA, MG, FE, NA, K, and hemolysis index and (4) G2-after versus G2-before storage only for BUN, AST, LDH, P, and CA. In conclusion, our results show that the MPA system improves the quality of laboratory testing.

  4. The analytical change in plasma creatinine that constitutes a biologic/physiologic change.

    PubMed

    Toffaletti, John G; Hammett-Stabler, Catherine A; Gearhart, Margaret; Roy Choudhury, Kingshuk; Handel, Elizabeth A

    2016-08-01

    Accurate and precise measurements of creatinine are necessary to evaluate changes in kidney function related to a decreased glomerular filtration rate (GFR). When serial measurements of creatinine are monitored in an individual, it is useful to know what magnitude of an analytical change in creatinine indicates a true physiologic/biologic change in plasma creatinine that might warrant clinical intervention. We compared results between three different methods for creatinine using large chemistry analyzers, two based on alkaline picrate (AP1 and AP2), and one based on dry-slide enzymatic conversion (ENZ). On each of three different segments or days of the study spaced 1-2months apart, we selected 10 different plasma samples having creatinine concentrations ranging from about 0.5mg/dL to 4.5mg/dL (44 to 400μmol/L). Each sample was analyzed in triplicate on each of two same-model analyzers at each institution, then from this data we determined the precision of each model of analyzer. The within-instrument precision of each analyzer was evaluated from the differences between the triplicate results on each sample by each analyzer (mean and SD of the differences). The between-instrument precision was evaluated as the differences between results on the same sample (1, 2, 3, etc.) analyzed on different analyzers of the same model (A and B). This between-analyzer precision data was used to determine both the range and mean±2SD of the differences that could be used to indicate that greater changes in creatinine concentrations would represent a biologic change. The within-instrument precision was best for the ENZ method in comparison to the two alkaline picrate rate methods. The between-instrument precision of the 90 consecutive measurements (30 samples×triplicate analyses) between the same-model analyzers were (mean and SD of differences in mg/dL): -0.018 and 0.029 (ENZ); 0.016 and 0.11 (AP1), and -0.058 and 0.071 (AP2). While all three of the creatinine methods studied had good precision, the ENZ method had the best precision, such that a change of 0.07mg/dL (6μmol/L) in serial creatinine concentrations up to 1.5mg/dL on a patient could indicate a biologic change had occurred. For the alkaline picrate methods, a measured change of creatinine of 0.23mg/dL for AP1 or 0.11mg/dL for AP2 would indicate that a physiologic change in serum/plasma creatinine has occurred. While a definite biologic change may simply represent daily variations, detecting a biologic change in creatinine more rapidly could impact the ability of creatinine to detect early and clinically significant changes in renal function. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Cookstove Emissions Quantified with the Aerodyne Mobile Laboratory During the Short Lived Climate Forcing (SLCF) 2013 Campaign in Pátzcuaro Mexico

    NASA Astrophysics Data System (ADS)

    Gonzalez Abraham, R.; Zavala, M.; Molina, L. T.; Fortner, E.; Wormhoudt, J.; Knighton, B.; Herndon, S.; Roscioli, J. R.; Onasch, T. B.; Jayne, J. T.; Worsnop, D. R.; Kolb, C. E.; Masera, O.; Berrueta, V.

    2013-12-01

    Black carbon emissions are a major contributor to climate change, with cookstoves being one of the top sources. The SLCF cookstove study was conducted in March 2013 at the Interdisciplinary Group for Appropriate Rural Technology (GIRA) in Pátzcuaro, Mexico. Seven different types of wood-burning cookstoves were measured giving insight to the effects of different designs and operating conditions on particle and gas phase emissions. High-time resolution measurements of emissions were made. For most of the cookstoves, measurements were made throughout a standard water boiling test. The Aerodyne Mobile Laboratory conducted these emission measurements utilizing extractive sampling from the stove exhaust. Sample flow to the gas phase instruments was extracted directly from the stovepipe and then quickly diluted with nitrogen. Sample flows for the particulate instruments were taken at points under a meter from the exit of the stovepipe, after dilution with ambient air. The key particulate instrument was the Aerodyne soot particle aerosol mass spectrometer (SP-AMS), which provided measurements of black carbon, divided into several sub-components, along with other classes of particulate matter classified by chemical composition. Gas phase measurements conducted included CO, CO2, NO, NOx, SO2, CH4, C2H2, C2H6, and a variety of VOCs (including benzene, methanol, acetaldehyde, toluene, acetone, acetonitrile, and terpene) measured with a PTR-MS instrument. All of these measurements will be examined to construct emission ratios evaluating how these vary with different cookstove types and different stove operating conditions. Comparisons will be made to previous measurements of cookstove emissions in the literature, with a focus on the variety of particulate measurements reported.

  6. Evaluation of conventional, protaper hand and protaper rotary instrumentation system for apical extrusion of debris, irrigants and bacteria- An in vitro randomized trial

    PubMed Central

    Kalra, Pinky; Suman, Ethel; Shenoy, Ramya; Suprabha, Baranya-Shrikrishna

    2017-01-01

    Background Endodontic instrumentation carries the risk of over extrusion of debris and bacteria. The technique used and the type of instrumentation influences this risk. Aim The purpose of this study was to evaluate and compare the K-file, ProTaper hand and ProTaper rotary instrumentation systems for the amount of apically extruded debris, irrigant solution and intracanal bacteria. Design Experimental single blinded randomized type of in vitro study with sample of 30 single rooted teeth. Endodontic access cavities were prepared and the root canals were filled with the suspension of E. faecalis. Myers and Montogomery Model was used to collect apically extruded debris and irrigant. Canals were prepared using K files, Hand protapers and Protaper rotary files. Statistical analysis Non Parametric test like Kruskal-Wallis and Mann-Whitney U test were applied to determine the significant differences among the group. Results Tests revealed statistically significant difference between the amount of debris and number of bacteria extruded by the ProTaper hand and the K-files. No statistically significant difference was observed between the amounts of irrigant extruded by the ProTaper hand and the K-file system. Statistically significant differences were observed between the amounts of bacteria and irrigant extruded by the ProTaper rotary and the Protaper hand. No statistically significant difference was observed between the amounts of debris extruded by the ProTaper hand and the K-file system. Conclusions Amount of apical extrusion of irrigant solution, bacteria and debris are significantly greater with K File instruments and least with Protaper rotary instruments. Key words:Protaper, rotary, periapical extrusion. PMID:28210445

  7. Development of quality of life instrument for urban poor in the northeast of Thailand.

    PubMed

    Surit, Phrutthinun; Laohasiriwong, Wongsa; Sanchaisuriya, Pattara; Schelp, Frank Perter

    2008-09-01

    Measuring the quality of life is important for evaluation and prediction of life and social care needs. To evaluate Quality of Life (QOL) in an urban poor population in northeast of Thailand, the Urban Poor Quality of Life (UPQOL) instrument was developed To develop an initial instrument to measure urban poor QOL. The development was started with literature review and investigated in urban poor communities. The results were transformed into the items required to build a structured questionnaire. Five hundred twenty three subjects, representatives of urban poor, were selected to test this instrument. Descriptive statistics described feature of items and the samples, exploratory factor analysis conducted the items score, and confirmatory factor analysis conducted the construct validity. The result found that the UPQOL instrument consisted of nine domains (education, income and employment, environment, health, infrastructure, security and safety, shelter and housing, civil society and political, and human rights domains) with egien value rank from 1.5 to 4.2 and 61 items with the factor loading rank from 0.41 to 0.82. The internal consistency was 0.92. The correlation between items to domain ranged from 0.30 to 0.72 and domains to overall QOL ranged from 0.27 to 0.84. Confirmatory factor analysis showed that the structure fit all domains well. Domains and overall structure were good with CFI (> 0.95). The internal consistency value ranged from 0.73-0.93. UPQOL scores were able to discriminate groups of subjects with differences levels of QOL. The UPQOL instrument is conceptually valid. The results support good validity and reliability. It forms the basis for future testing and application in other settings.

  8. Developing a cultural competence inventory for nurses in China.

    PubMed

    Cai, D; Kunaviktikul, W; Klunklin, A; Sripusanapan, A; Avant, P K

    2017-06-01

    To develop and psychometrically test the Cultural Competence Inventory for Nurses in China. Cultural competence is expected worldwide from nurses due to the increasing cultural diversity of people in healthcare establishments. Yet, no cultural competence framework or instrument for nurses has been identified to guide nursing practice in China where the cultural diversity of the populations and the characteristics of the healthcare system are different from those of the West. A review of literature and individual interviews among nurse experts generated 74 items, which were evaluated by six experts in transcultural nursing. A stratified random sampling technique was used to recruit 520 Chinese nurses for the field test. Construct validity and internal consistency reliability of the instrument were estimated by exploratory factor analysis and Cronbach's alpha, respectively. The data were collected from May 2015 to January 2016. The final instrument consists of 29 items in five dimensions, namely 'cultural awareness, cultural respect, cultural knowledge, cultural understanding and cultural skills'. Cronbach's alpha for the instrument was 0.94, with a range of 0.79-0.92 for the individual dimensions. The evidence for contrast-group validity (P < 0.001) was also obtained. The study provides evidence that the Cultural Competence Inventory for Nurses in China is reliable, valid and culturally sensitive for measuring nurses' cultural competence. The instrument development process facilitates the understanding of cultural competence globally. Cultural competence of nurses can be evaluated for self-development, workforce management and quality assurance. The instrument can also serve as the foundation to develop education curricula and nursing procedures or protocols to improve culturally competent nursing practice. © 2017 International Council of Nurses.

  9. Occurrence of microplastics in the coastal marine environment: First observation on sediment of China.

    PubMed

    Qiu, Qiongxuan; Peng, Jinping; Yu, Xubiao; Chen, Fangchaizi; Wang, Jundong; Dong, Fenqiang

    2015-09-15

    Microplastics in sediments from the Beibu Gulf and the coastline of China Sea were investigated to evaluate the occurrence and abundance of microplastics in China for the first time. Microplastics (<5mm) were taken from sediments by a flotation method. The number of microplastics was counted by a fluorescence microscope, an instrument that is rarely used in the detection of microplastics in sediments. This instrument led to results that were satisfactory. Compared with other sampled areas, microplastics were found in massive concentrations in China. Four types of microplastics, HDPE, PET, PE and PS, were identified. The results will provide useful background information for further investigations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Quality of integrated chronic care measured by patient survey: identification, selection and application of most appropriate instruments

    PubMed Central

    Vrijhoef, Hubertus J. M.; Berbee, Rieneke; Wagner, Edward H.; Steuten, Lotte M. G.

    2009-01-01

    Abstract Objective  To identify the most appropriate generic instrument to measure experience and/or satisfaction of people receiving integrated chronic care. Background  Health care is becoming more user‐centred and, as a result, the experience of users of care and evaluation of their experience and/or satisfaction is taken more seriously. It is unclear to what extent existing instruments are appropriate in measuring the experience and/or satisfaction of people using integrated chronic care. Methods  Instruments were identified by means of a systematic literature review. Appropriateness of instruments was analysed on seven criteria. The two most promising instruments were translated into Dutch, if necessary, and administered to a convenience sample of 109 people with a chronic illness. Data derived from respondents were analysed statistically. Focus‐group interviews were conducted to assess the semantic and technical equivalence as well as opinions of people about the applicability and relevance of the translated instruments. Results  From 37 instruments identified, the Patients’ Assessment of Care for chronIc Conditions (PACIC) and the short form of the Patient Satisfaction Questionnaire III (PSQ‐18) were selected as most promising instruments. Both instruments produced similar median scores across people with different chronic conditions. The overall PACIC and its subscales and the overall PSQ‐18 were highly internally consistent, but not the PSQ‐18 subscales. Overall, the PACIC demonstrated better psychometric characteristics. PACIC and PSQ‐18 scores were found to be moderately correlated. Whereas more respondents preferred the PSQ‐18, focus‐group participants regarded the PACIC to be more applicable and relevant. The technical and semantic equivalence of both instruments were sufficient. Conclusions  Because of its psychometric characteristics, perceived applicability and relevance, the PACIC is the most appropriate instrument to measure the experience of people receiving integrated chronic care. PMID:19709315

  11. Making Sense of Complex Problems: A Resource for Teams

    DTIC Science & Technology

    2015-12-01

    instruments, interviews, and a writing assignment to mirror those characteristics and skills. Candidates were evaluated in terms of that set of criteria, and...and those who are metacognitive thinkers, and can reflect and comment on how the team is thinking about a particular topic...The Cognitive- Style Inventory (see Tools and Resources for references). Writing samples and other examples of work products These products can

  12. In-Situ Water Vapor Probe for a Robot Arm-Mounted, Compact Water Vapor Analyzer: Preliminary Results

    NASA Technical Reports Server (NTRS)

    Socki, Richard A.; Niles, Paul B.; Cabiran, Mike; Rossi, Chris; Sun, Tao

    2013-01-01

    This work describes the ongoing development of an instrument package for the in-situ detection and isotopic analysis of water (from ice, icy soils, and hydrated minerals) on future lunar, asteroid, or martian exploration missions. This instrument is intended to be mounted on a robotic arm and be brought to the sample, rather than necessitating expensive and complicated sample handling to bring the sample to the instrument.

  13. HAI: A novel airborne multi-channel hygrometer for fast multi-phase H2O quantification: Performance of the HAI instrument during the first flights on the German HALO aircraft

    NASA Astrophysics Data System (ADS)

    Buchholz, B.; Ebert, V.; Kraemer, M.; Afchine, A.

    2014-12-01

    Common gas phase H2O measurements on fast airborne platforms e.g. using backward facing or "Rosemount"-inlets can lead to a high risk of ice and droplets contamination. In addition, currently no single hygrometer exists that allows a simultaneous, high-speed measurement of all phases (gas, liquid, ice) with the same detection principle. In the rare occasions multi-phase measurements are realized, gas-and condensed-phase observations rely on different methods, instruments and calibration strategies so that precision and accuracy levels are quite difficult to quantify. This is effectively avoided by the novel TDLAS instrument, HAI, Hygrometer for Atmospheric Investigation, which allows a simultaneous, high speed, multi-phase detection without any sensor calibration in a unique "2+2" channel concept. Hai combines two independent wavelength channels, at 1.4 µm and at 2.6 µm, for a wide dynamic range from 1 to 30 000 ppmv, with a simultaneous closed path (extractive) and open path detection. Thus, "Total", i.e. gas-phase plus condensed-phase water is measured by sampling via a forward facing inlet into "closed-path" extractive cells. A selective, sampling-free, high speed gas phase detection is realized via a dual-wavelength "open-path" cell placed outside of the aircraft fuselage. All channels can be sampled with 120 Hz (measurement cycle time Dt=1.6 ms) allowing an unprecedented spatial resolution of 30 cm at 900 km/h. The evaluation of the individual multi-channel raw-data is done post flight, without any channel interdependencies, in calibration-free mode, thus allowing fast, accurate and precise multi-phase water detection in flight. The performance could be shown in more than 200 net flights hours in three scientific flight campaigns (TACTS, ESMVal, ML-CIRRUS) on the new German HALO aircraft. In addition the level of the accuracy of the calibration free evaluation was evaluated at the German national primary water vapor standard.

  14. [Development of an evaluation instrument for service quality in nursing homes].

    PubMed

    Lee, Jia; Ji, Eun Sun

    2011-08-01

    The purposes of this study were to identify the factors influencing service quality in nursing homes, and to develop an evaluation instrument for service quality. A three-phase process was employed for the study. 1) The important factors to evaluate the service quality in nursing homes were identified through a literature review, panel discussion and focus group interview, 2) the evaluation instrument was developed, and 3) validity and reliability of the study instrument were tested by factor analysis, Pearson correlation coefficient, Cronbach's α and Cohen's Kappa. Factor analysis showed that the factors influencing service quality in nursing homes were healthcare, diet/assistance, therapy, environment and staff. To improve objectivity of the instrument, quantitative as well as qualitative evaluation approaches were adopted. The study instrument was developed with 30 items and showed acceptable construct validity. The criterion-related validity was a Pearson correlation coefficient of .85 in 151 care facilities. The internal consistency was Cronbach's α=.95. The instrument has acceptable validity and a high degree of reliability. Staff in nursing homes can continuously improve and manage their services using the results of the evaluation instrument.

  15. Targeted Proteomic Quantification on Quadrupole-Orbitrap Mass Spectrometer*

    PubMed Central

    Gallien, Sebastien; Duriez, Elodie; Crone, Catharina; Kellmann, Markus; Moehring, Thomas; Domon, Bruno

    2012-01-01

    There is an immediate need for improved methods to systematically and precisely quantify large sets of peptides in complex biological samples. To date protein quantification in biological samples has been routinely performed on triple quadrupole instruments operated in selected reaction monitoring mode (SRM), and two major challenges remain. Firstly, the number of peptides to be included in one survey experiment needs to be increased to routinely reach several hundreds, and secondly, the degree of selectivity should be improved so as to reliably discriminate the targeted analytes from background interferences. High resolution and accurate mass (HR/AM) analysis on the recently developed Q-Exactive mass spectrometer can potentially address these issues. This instrument presents a unique configuration: it is constituted of an orbitrap mass analyzer equipped with a quadrupole mass filter as the front-end for precursor ion mass selection. This configuration enables new quantitative methods based on HR/AM measurements, including targeted analysis in MS mode (single ion monitoring) and in MS/MS mode (parallel reaction monitoring). The ability of the quadrupole to select a restricted m/z range allows one to overcome the dynamic range limitations associated with trapping devices, and the MS/MS mode provides an additional stage of selectivity. When applied to targeted protein quantification in urine samples and benchmarked with the reference SRM technique, the quadrupole-orbitrap instrument exhibits similar or better performance in terms of selectivity, dynamic range, and sensitivity. This high performance is further enhanced by leveraging the multiplexing capability of the instrument to design novel acquisition methods and apply them to large targeted proteomic studies for the first time, as demonstrated on 770 tryptic yeast peptides analyzed in one 60-min experiment. The increased quality of quadrupole-orbitrap data has the potential to improve existing protein quantification methods in complex samples and address the pressing demand of systems biology or biomarker evaluation studies. PMID:22962056

  16. The effectiveness of increased apical enlargement in reducing intracanal bacteria.

    PubMed

    Card, Steven J; Sigurdsson, Asgeir; Orstavik, Dag; Trope, Martin

    2002-11-01

    It has been suggested that the apical portion of a root canal is not adequately disinfected by typical instrumentation regimens. The purpose of this study was to determine whether instrumentation to sizes larger than typically used would more effectively remove culturable bacteria from the canal. Forty patients with clinical and radiographic evidence of apical periodontitis were recruited from the endodontic clinic. Mandibular cuspids (n = 2), bicuspids (n = 11), and molars (mesial roots) (n = 27) were selected for the study. Bacterial sampling was performed upon access and after each of two consecutive instrumentations. The first instrumentation utilized 1% NaOCI and 0.04 taper ProFile rotary files. The cuspid and bicuspid canals were instrumented to a #8 size and the molar canals to a #7 size. The second instrumentation utilized LightSpeed files and 1% NaOCl irrigation for further enlargement of the apical third. Typically, molars were instrumented to size 60 and cuspid/bicuspid canals to size 80. Our findings show that 100% of the cuspid/bicuspid canals and 81.5% of the molar canals were rendered bacteria-free after the first instrumentation sizes. The molar results improved to 89% after the second instrumentation. Of the (59.3%) molar mesial canals without a clinically detectable communication, 93% were rendered bacteria-free with the first instrumentation. Using a Wilcoxon rank sum test, statistically significant differences (p < 0.0001) were found between the initial sample and the samples after the first and second instrumentations. The differences between the samples that followed the two instrumentation regimens were not significant (p = 0.0617). It is concluded that simple root canal systems (without multiple canal communications) may be rendered bacteria-free when preparation of this type is utilized.

  17. Development and Psychometric Evaluation of a Health-Related Quality of Life Instrument for Individuals with Adult-Onset Hearing Loss

    PubMed Central

    Stika, Carren J.; Hays, Ron D.

    2016-01-01

    Objective Self-reports of “hearing handicap” are available, but a comprehensive measure of health-related quality of life (HRQOL) for individuals with adult-onset hearing loss (AOHL) does not exist. Our objective was to develop and evaluate a multidimensional HRQOL instrument for individuals with AOHL. Design The Impact of Hearing Loss Inventory Tool (IHEAR-IT) was developed using results of focus groups, a literature review, Advisory Expert Panel input, and cognitive interviews. Study Sample The 73-item field-test instrument was completed by 409 adults (22-91 years old) with varying degrees of AOHL and from different areas of the US. Results Multitrait scaling analysis supported four multi-item scales and five individual items. Internal consistency reliabilities ranged from 0.93 to 0.96 for the scales. Construct validity was supported by correlations between the IHEAR-IT scales and scores on the 36-Item Short Form Health Survey, Version 2.0 (SF-36v2) Mental Composite Summary (r’s = 0.32 – 0.64) and the Hearing Handicap Inventory for the Elderly/Adults (HHIE/HHIA) (r’s > −0.70). Conclusions The field test provide initial support for the reliability and construct validity of the IHEAR-IT for evaluating HRQOL of individuals with AOHL. Further research is needed to evaluate the responsiveness to change of the IHEAR-IT scales and identify items for a short-form. PMID:27104754

  18. Development and Validation of an Instrument Measuring Theory-Based Determinants of Monitoring Obesogenic Behaviors of Pre-Schoolers among Hispanic Mothers.

    PubMed

    Branscum, Paul; Lora, Karina R

    2016-06-02

    Public health interventions are greatly needed for obesity prevention, and planning for such strategies should include community participation. The study's purpose was to develop and validate a theory-based instrument with low-income, Hispanic mothers of preschoolers, to assess theory-based determinants of maternal monitoring of child's consumption of fruits and vegetables and sugar-sweetened beverages (SSB). Nine focus groups with mothers were conducted to determine nutrition-related behaviors that mothers found as most obesogenic for their children. Next, behaviors were operationally defined and rated for importance and changeability. Two behaviors were selected for investigation (fruits and vegetable and SSB). Twenty semi-structured interviews with mothers were conducted next to develop culturally appropriate items for the instrument. Afterwards, face and content validity were established using a panel of six experts. Finally, the instrument was tested with a sample of 238 mothers. Psychometric properties evaluated included construct validity (using the maximum likelihood extraction method of factor analysis), and internal consistency reliability (Cronbach's alpha). Results suggested that all scales on the instrument were valid and reliable, except for the autonomy scales. Researchers and community planners working with Hispanic families can use this instrument to measure theory-based determinants of parenting behaviors related to preschoolers' consumption of fruits and vegetables, and SSB.

  19. Quantifying the extruded bacteria following use of two rotary instrumentation systems.

    PubMed

    Mohammadi, Zahed; Khademi, Abbasali

    2007-01-01

    All instrumentation techniques have been reported to be associated with extrusion of infected debris. The aim of this study was to evaluate the number of bacteria extruded apically from extracted teeth ex vivo after canal instrumentation using the two engine-driven techniques utilizing nickel-titanium instruments (Flex Master and Mtwo). Seventy extracted maxillary central incisor teeth were used. Access cavities were prepared and root canals were then contaminated with a suspension of Enterococcus faecalis and dried. The contaminated roots were divided into two experimental groups of 30 teeth each and one control group of 10 teeth. Group 1, Flex Master; Group2, Mtwo; Group 3, control group: no instrumentation was attempted. Bacteria extruded from the apical foramen during instrumentation were collected into vials. The microbiological samples from the vials were incubated in culture media for 24 h. Colonies of bacteria were counted and the results were given as number of colony-forming units. The obtained data were analyzed using the Kruskal-Wallis one-way analysis of variance and Mann-Whitney U-tests, with α = 0.05 as the level for statistical significance. Findings showed that there was no significant difference as to the number of extruded bacteria between two engine-driven systems (P>0.05). Both engine-driven Nickel-Titanium systems extruded bacteria through the apical foramen.

  20. A systematic review of instruments that measure attitudes toward homosexual men.

    PubMed

    Grey, Jeremy A; Robinson, Beatrice Bean E; Coleman, Eli; Bockting, Walter O

    2013-01-01

    Scientific interest in the measurement of homophobia and internalized homophobia has grown over the past 30 years, and new instruments and terms have emerged. To help researchers with the challenging task of identifying appropriate measures for studies in sexual-minority health, we reviewed measures of homophobia published in the academic literature from 1970 to 2012. Instruments that measured attitudes toward male homosexuals/homosexuality or measured homosexuals' internalized attitudes toward homosexuality were identified using measurement manuals and a systematic review. A total of 23 instruments met criteria for inclusion, and their features were summarized and compared. All 23 instruments met minimal criteria for adequate scale construction, including scale development, sampling, reliability, and evidence of validity. Validity evidence was diverse and was categorized as interaction with gay men, HIV/AIDS variables, mental health, and conservative religious or political beliefs. Homophobia was additionally correlated with authoritarianism and bias, gender ideology, gender differences, and reactions to homosexual stimuli. Internalized homophobia was validated by examining relationships with disclosing one's homosexuality and level of homosexual identity development. We hope this review will make the process of instrument selection more efficient by allowing researchers to easily locate, evaluate, and choose the proper measure based on their research question and population of interest.

Top