Chloupek, Petr; Bedanova, Iveta; Chloupek, Jan; Vecerek, Vladimir
2011-05-13
Since it is not yet clear whether it is possible to satisfactorily avoid sampling-induced stress interference in poultry, more studies on the pattern of physiological response and detailed quantification of stress connected with the first few minutes of capture and pre-sampling handling in poultry are required. This study focused on detection of changes in the corticosterone level and concentrations of other selected biochemical parameters in broilers handled in two different manners during blood sampling (involving catching, carrying, restraint, and blood collection itself) that lasted for various time periods within the interval 30-180 seconds. Stress effects of pre-sampling handling were studied in a group (n = 144) of unsexed ROSS 308 broiler chickens aged 42 d. Handling (catching, carrying, restraint, and blood sampling itself) was carried out in a gentle (caught, held and carried carefully in an upright position) or rough (caught by the leg, held and carried with lack of care in inverted position) manner and lasted for 30 s, 60 s, 90 s, 120 s, 150 s, and 180 s. Plasma corticosterone, albumin, glucose, cholesterol, lactate, triglycerides and total protein were measured in order to assess the stress-induced changes to these biochemical indices following handling in the first few minutes of capture. Pre-sampling handling in a rough manner resulted in considerably higher plasma concentrations of all biochemical indices monitored when compared with gentle handling. Concentrations of plasma corticosterone after 150 and 180 s of handling were considerably higher (P < 0.01) than concentrations after 30-120 s of handling regardless of handling technique. Concentrations of plasma lactate were also increased by prolonged handling duration. Handling for 90-180 seconds resulted in a highly significant elevation of lactate concentration in comparison with 30 s handling regardless of handling technique. Similarly to corticosterone concentrations, a strong positive correlation was found between plasma lactate and duration of pre-sampling handling. Other biochemical indices monitored did not show any correlation pattern in connection with duration of pre-sampling handling. These results indicate that the pre-sampling procedure may be a considerably stressful procedure for broilers, particularly when carried out with lack of care and exceeding 120 seconds.
TECHNIQUES WITH POTENTIAL FOR HANDLING ENVIRONMENTAL SAMPLES IN CAPILLARY ELECTROPHORESIS
An assessment of the methods for handling environmental samples prior to capillary electrophoresis (CE) is presented for both aqueous and solid matrices. Sample handling in environmental analyses is the subject of ongoing research at the Environmental Protection Agency's National...
2011-01-01
Background Since it is not yet clear whether it is possible to satisfactorily avoid sampling-induced stress interference in poultry, more studies on the pattern of physiological response and detailed quantification of stress connected with the first few minutes of capture and pre-sampling handling in poultry are required. This study focused on detection of changes in the corticosterone level and concentrations of other selected biochemical parameters in broilers handled in two different manners during blood sampling (involving catching, carrying, restraint, and blood collection itself) that lasted for various time periods within the interval 30-180 seconds. Methods Stress effects of pre-sampling handling were studied in a group (n = 144) of unsexed ROSS 308 broiler chickens aged 42 d. Handling (catching, carrying, restraint, and blood sampling itself) was carried out in a gentle (caught, held and carried carefully in an upright position) or rough (caught by the leg, held and carried with lack of care in inverted position) manner and lasted for 30 s, 60 s, 90 s, 120 s, 150 s, and 180 s. Plasma corticosterone, albumin, glucose, cholesterol, lactate, triglycerides and total protein were measured in order to assess the stress-induced changes to these biochemical indices following handling in the first few minutes of capture. Results Pre-sampling handling in a rough manner resulted in considerably higher plasma concentrations of all biochemical indices monitored when compared with gentle handling. Concentrations of plasma corticosterone after 150 and 180 s of handling were considerably higher (P < 0.01) than concentrations after 30-120 s of handling regardless of handling technique. Concentrations of plasma lactate were also increased by prolonged handling duration. Handling for 90-180 seconds resulted in a highly significant elevation of lactate concentration in comparison with 30 s handling regardless of handling technique. Similarly to corticosterone concentrations, a strong positive correlation was found between plasma lactate and duration of pre-sampling handling. Other biochemical indices monitored did not show any correlation pattern in connection with duration of pre-sampling handling. Conclusions These results indicate that the pre-sampling procedure may be a considerably stressful procedure for broilers, particularly when carried out with lack of care and exceeding 120 seconds. PMID:21569531
ERIC Educational Resources Information Center
Maienthal, E. J.; Becker, D. A.
This report presents the results of an extensive literature survey undertaken to establish optimum sampling, sample handling and long-term storage techniques for a wide variety of environmental samples to retain sample integrity. The components of interest are trace elements, organics, pesticides, radionuclides and microbiologicals. A bibliography…
Novel Sample-handling Approach for XRD Analysis with Minimal Sample Preparation
NASA Technical Reports Server (NTRS)
Sarrazin, P.; Chipera, S.; Bish, D.; Blake, D.; Feldman, S.; Vaniman, D.; Bryson, C.
2004-01-01
Sample preparation and sample handling are among the most critical operations associated with X-ray diffraction (XRD) analysis. These operations require attention in a laboratory environment, but they become a major constraint in the deployment of XRD instruments for robotic planetary exploration. We are developing a novel sample handling system that dramatically relaxes the constraints on sample preparation by allowing characterization of coarse-grained material that would normally be impossible to analyze with conventional powder-XRD techniques.
1985-06-01
of chemical analysis and sensitivity testing on material samples . At this 4 time, these samples must be packaged and...preparation at a rate of three samples per hour. One analyst doing both sample preparation and the HPLC analysis can run 16 samples in an 8-hour day. II... study , sensitivity testing was reviewed to enable recommendations for complete analysis of contaminated soils. Materials handling techniques,
Cleaning and Cleanliness Verification Techniques for Mars Returned Sample Handling
NASA Technical Reports Server (NTRS)
Mickelson, E. T.; Lindstrom, D. J.; Allton, J. H.; Hittle, J. D.
2002-01-01
Precision cleaning and cleanliness verification techniques are examined as a subset of a comprehensive contamination control strategy for a Mars sample return mission. Additional information is contained in the original extended abstract.
Effects of core retrieval, handling, and preservation on hydrate-bearing samples
NASA Astrophysics Data System (ADS)
Kneafsey, T. J.; Lu, H.; Winters, W. J.; Hunter, R. B.
2009-12-01
Recovery, preservation, storage, and transport of samples containing natural gas hydrate cause changes in the stress conditions, temperature, pressure, and hydrate saturation of samples. Sample handling at the ground surface and sample preservation, either by freezing in liquid nitrogen (LN) or repressurization using methane, provides additional time and driving forces for sample alteration. The extent to which these disturbances alter the properties of the hydrate bearing sediments (HBS) depend on specific sample handling techniques, as well as on the sample itself. HBS recovered during India’s National Gas Hydrate Program (NGHP) Expedition 01 and the 2007 BP Exploration Alaska - Department of Energy - U.S. Geological Survey (BP-DOE-USGS) Mount Elbert (ME) gas hydrate well on the Alaskan North Slope provide comparisons of sample alterations induced by multiple handling techniques. HBS samples from the NGHP and the ME projects were examined using x-ray computed tomography. Mount Elbert sand samples initially preserved in LN have non-uniform short “crack-like” low-density zones in the center that probably do not extend to the outside perimeter. Samples initially preserved by repressurization show fewer “crack-like” features and higher densities. Two samples were analyzed in detail by Lu and coworkers showing reduced hydrate saturations approaching the outer surface, while substantial hydrate remained in the central region. Non-pressure cored NGHP samples show relatively large altered regions approaching the core surface, while pressure-cored-liquid-nitrogen preserved samples have much less alteration.
Advanced Curation Protocols for Mars Returned Sample Handling
NASA Astrophysics Data System (ADS)
Bell, M.; Mickelson, E.; Lindstrom, D.; Allton, J.
Introduction: Johnson Space Center has over 30 years experience handling precious samples which include Lunar rocks and Antarctic meteorites. However, we recognize that future curation of samples from such missions as Genesis, Stardust, and Mars S mple Return, will require a high degree of biosafety combined witha extremely low levels of inorganic, organic, and biological contamination. To satisfy these requirements, research in the JSC Advanced Curation Lab is currently focused toward two major areas: preliminary examination techniques and cleaning and verification techniques . Preliminary Examination Techniques : In order to minimize the number of paths for contamination we are exploring the synergy between human &robotic sample handling in a controlled environment to help determine the limits of clean curation. Within the Advanced Curation Laboratory is a prototype, next-generation glovebox, which contains a robotic micromanipulator. The remotely operated manipulator has six degrees-of- freedom and can be programmed to perform repetitive sample handling tasks. Protocols are being tested and developed to perform curation tasks such as rock splitting, weighing, imaging, and storing. Techniques for sample transfer enabling more detailed remote examination without compromising the integrity of sample science are also being developed . The glovebox is equipped with a rapid transfer port through which samples can be passed without exposure. The transfer is accomplished by using a unique seal and engagement system which allows passage between containers while maintaining a first seal to the outside environment and a second seal to prevent the outside of the container cover and port door from becoming contaminated by the material being transferred. Cleaning and Verification Techniques: As part of the contamination control effort, innovative cleaning techniques are being identified and evaluated in conjunction with sensitive cleanliness verification methods. Towards this end, cleaning techniques such as ultrasonication in ultra -pure water (UPW), oxygen (O2) plasma, and carbon dioxide (CO2) "snow" are being used to clean a variety of different contaminants on a variety of different surfaces. Additionally, once cleaned, techniques to directly verify the s rface cleanliness are being developed. Theseu include X ray photoelectron spectroscopy (XPS) quantification, and screening with- contact angle measure ments , which can be correlated with XPS standards. Methods developed in the Advanced Curation Laboratory will determine the extent to which inorganic and biological contamination can be controlled and minimized.
NASA Technical Reports Server (NTRS)
Allton, J. H.; Zeigler, R. A.; Calaway, M. J.
2016-01-01
The Lunar Receiving Laboratory (LRL) was planned and constructed in the 1960s to support the Apollo program in the context of landing on the Moon and safely returning humans. The enduring science return from that effort is a result of careful curation of planetary materials. Technical decisions for the first facility included sample handling environment (vacuum vs inert gas), and instruments for making basic sample assessment, but the most difficult decision, and most visible, was stringent biosafety vs ultra-clean sample handling. Biosafety required handling of samples in negative pressure gloveboxes and rooms for containment and use of sterilizing protocols and animal/plant models for hazard assessment. Ultra-clean sample handling worked best in positive pressure nitrogen environment gloveboxes in positive pressure rooms, using cleanable tools of tightly controlled composition. The requirements for these two objectives were so different, that the solution was to design and build a new facility for specific purpose of preserving the scientific integrity of the samples. The resulting Lunar Curatorial Facility was designed and constructed, from 1972-1979, with advice and oversight by a very active committee comprised of lunar sample scientists. The high precision analyses required for planetary science are enabled by stringent contamination control of trace elements in the materials and protocols of construction (e.g., trace element screening for paint and flooring materials) and the equipment used in sample handling and storage. As other astromaterials, especially small particles and atoms, were added to the collections curated, the technical tension between particulate cleanliness and organic cleanliness was addressed in more detail. Techniques for minimizing particulate contamination in sample handling environments use high efficiency air filtering techniques typically requiring organic sealants which offgas. Protocols for reducing adventitious carbon on sample handling surfaces often generate particles. Further work is needed to achieve both minimal particulate and adventitious carbon contamination. This paper will discuss these facility topics and others in the historical context of nearly 50 years' curation experience for lunar rocks and regolith, meteorites, cosmic dust, comet particles, solar wind atoms, and asteroid particles at Johnson Space Center.
Yu, Tzy-Chyi; Zhou, Huanxue
2015-09-01
Evaluate performance of techniques used to handle missing cost-to-charge ratio (CCR) data in the USA Healthcare Cost and Utilization Project's Nationwide Inpatient Sample. Four techniques to replace missing CCR data were evaluated: deleting discharges with missing CCRs (complete case analysis), reweighting as recommended by Healthcare Cost and Utilization Project, reweighting by adjustment cells and hot deck imputation by adjustment cells. Bias and root mean squared error of these techniques on hospital cost were evaluated in five disease cohorts. Similar mean cost estimates would be obtained with any of the four techniques when the percentage of missing data is low (<10%). When total cost is the outcome of interest, a reweighting technique to avoid underestimation from dropping observations with missing data should be adopted.
Bregnbak, David; Thyssen, Jacob P; Jellesen, Morten S; Zachariae, Claus; Johansen, Jeanne D
2016-08-01
Chromium is an important skin sensitizer. Exposure to it has been regulated in cement, and recently in leather. Studies on the deposition of chromium ions on the skin as a result of handling different chromium-containing materials are sparse, but could improve the risk assessment of contact sensitization and allergic contact dermatitis caused by chromium. To determine whether the handling of chromium-containing samples of leather and metal results in the deposition of chromium onto the skin. Five healthy volunteers participated. For 30 min, they handled samples of leather and metal known to contain and release chromium. Skin deposition of chromium was assessed with the acid wipe sampling technique. Acid wipe sampling of the participants' fingers showed chromium deposition on the skin in all participants who had been exposed to leather (range 0.01-0.20 µg/cm(2) ) and in 3 of 5 participants after they had manually handled metal discs (range 0.02-0.04 µg/cm(2) ). We found that samples of leather and metal had the ability to deposit chromium on the skin at significant levels, in spite of a short duration of exposure. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Predictive Techniques for Spacecraft Cabin Air Quality Control
NASA Technical Reports Server (NTRS)
Perry, J. L.; Cromes, Scott D. (Technical Monitor)
2001-01-01
As assembly of the International Space Station (ISS) proceeds, predictive techniques are used to determine the best approach for handling a variety of cabin air quality challenges. These techniques use equipment offgassing data collected from each ISS module before flight to characterize the trace chemical contaminant load. Combined with crew metabolic loads, these data serve as input to a predictive model for assessing the capability of the onboard atmosphere revitalization systems to handle the overall trace contaminant load as station assembly progresses. The techniques for predicting in-flight air quality are summarized along with results from early ISS mission analyses. Results from groundbased analyses of in-flight air quality samples are compared to the predictions to demonstrate the technique's relative conservatism.
Bacterial Contamination and Disinfection Status of Laryngoscopes Stored in Emergency Crash Carts
Lee, Jung Won; Shin, Hee Bong; Lee, In Kyung
2017-01-01
Objectives To identify bacterial contamination rates of laryngoscope blades and handles stored in emergency crash carts by hospital and area according to the frequency of intubation attempts. Methods One hundred forty-eight handles and 71 blades deemed ready for patient use from two tertiary hospitals were sampled with sterile swabs using a standardized rolling technique. Samples were considered negative (not contaminated) if no colonies were present on the blood agar plate after an 18-hour incubation period. Samples were stratified by hospital and according to the frequency of intubation attempts (10 attempts per year) using the χ2-test and Fisher exact test. Results One or more species of bacteria were isolated from 4 (5.6%) handle tops, 20 (28.2%) handles with knurled surfaces, and 27 (18.2%) blades. No significant differences were found in microbial contamination levels on the handle tops and blades between the two hospitals and two areas according to the frequency of intubation attempts. However, significant differences were found between the two hospitals and two areas in the level of microbial contamination on the handles with knurled surfaces (p<0.05). Conclusions Protocols and policies must be reviewed to standardize procedures to clean and disinfect laryngoscope blades and handles; handles should be re-designed to eliminate points of contact with the blade; and single-use, one-piece laryngoscopes should be introduced. PMID:28605891
Accurate high-speed liquid handling of very small biological samples.
Schober, A; Günther, R; Schwienhorst, A; Döring, M; Lindemann, B F
1993-08-01
Molecular biology techniques require the accurate pipetting of buffers and solutions with volumes in the microliter range. Traditionally, hand-held pipetting devices are used to fulfill these requirements, but many laboratories have also introduced robotic workstations for the handling of liquids. Piston-operated pumps are commonly used in manually as well as automatically operated pipettors. These devices cannot meet the demands for extremely accurate pipetting of very small volumes at the high speed that would be necessary for certain applications (e.g., in sequencing projects with high throughput). In this paper we describe a technique for the accurate microdispensation of biochemically relevant solutions and suspensions with the aid of a piezoelectric transducer. It is suitable for liquids of a viscosity between 0.5 and 500 milliPascals. The obtainable drop sizes range from 5 picoliters to a few nanoliters with up to 10,000 drops per second. Liquids can be dispensed in single or accumulated drops to handle a wide volume range. The system proved to be excellently suitable for the handling of biological samples. It did not show any detectable negative impact on the biological function of dissolved or suspended molecules or particles.
Esteruelas, Núria Fandos; Huber, Nikolaus; Evans, Alina L; Zedrosser, Andreas; Cattet, Marc; Palomares, Francisco; Angel, Martine; Swenson, Jon E; Arnemo, Jon M
2016-04-01
Brown bears (Ursus arctos) are often captured and handled for research and management purposes. Although the techniques used are potentially stressful for the animals and might have detrimental and long-lasting consequences, it is difficult to assess their physiological impact. Here we report the use of the leukocyte coping capacity (LCC) technique to quantify the acute stress of capture and handling in brown bears in Scandinavia. In April and May 2012 and 2013, we collected venous blood samples and recorded a range of physiological variables to evaluate the effects of capture and the added impact of surgical implantation or removal of transmitters and sensors. We studied 24 brown bears, including 19 that had abdominal surgery. We found 1) LCC values following capture were lower in solitary bears than in bears in family groups suggesting capture caused relatively more stress in solitary bears, 2) ability to cope with handling stress was better (greater LCC values) in bears with good body condition, and 3) LCC values did not appear to be influenced by surgery. Although further evaluation of this technique is required, our preliminary results support the use of the LCC technique as a quantitative measure of stress.
NASA Astrophysics Data System (ADS)
Spangenberg, T.; Göttlicher, J.; Steininger, R.
2016-05-01
An efficient referencing and sample positioning system is a basic tool for a micro focus beamline at a synchrotron. The seven years ago introduced command line based system was upgraded at SUL-X beamline at ANKA [1]. A new combination of current server client techniques offers direct control and facilitates unexperienced users the handling of this frequently used tool.
Dielectrophoretic manipulation of particles for use in microfluidic devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belgrader, P; Bettencourt, K; Hamilton, J
1999-06-23
Amplification and hybridization of DNA are commonly used techniques to verify the presence of a specific DNA sequence in a test sample. Automatic sample handling to concentrate and purify sample prior to amplification is desirable both from the cost standpoint and from the standpoint of reducing the possibility of sample contamination. This paper explores the use of the dielectrophoretic force to manipulate DNA, Bacillus globigii spores, and Erwinia herbicola bacteria to provide concentration and purification as part of the sample handling functions in biological monitoring equipment. It was found that for what would be considered a typical microfabricated structure withmore » electrode gaps at 30 {micro}m operating at 5V, that concentration of the particles is very effective.« less
Microscopic Analysis of Activated Sludge. Training Manual.
ERIC Educational Resources Information Center
Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.
This training manual presents material on the use of a compound microscope to analyze microscope communities, present in wastewater treatment processes, for operational control. Course topics include: sampling techniques, sample handling, laboratory analysis, identification of organisms, data interpretation, and use of the compound microscope.…
Collecting, preparing, crossdating, and measuring tree increment cores
Phipps, R.L.
1985-01-01
Techniques for collecting and handling increment tree cores are described. Procedures include those for cleaning and caring for increment borers, extracting the sample from a tree, core surfacing, crossdating, and measuring. (USGS)
Microbiological sampling of spacecraft cabling, antennas, solar panels and thermal blankets
NASA Technical Reports Server (NTRS)
Koukol, R. C.
1973-01-01
Sampling procedures and techniques described resulted from various flight project microbiological monitoring programs of unmanned planetary spacecraft. Concurrent with development of these procedures, compatibility evaluations were effected with the cognizant spacecraft subsystem engineers to assure that degradation factors would not be induced during the monitoring program. Of significance were those areas of the spacecraft configuration for which special handling precautions and/or nonstandard sample gathering techniques were evolved. These spacecraft component areas were: cabling, high gain antenna, solar panels, and thermal blankets. The compilation of these techniques provides a historical reference for both the qualification and quantification of sampling parameters as applied to the Mariner Spacecraft of the late 1960's and early 1970's.
Mass Spectrometric Rapid Diagnosis of Infectious Diseases.
1980-01-01
the analytical procedures to warrant reporting anew the whole analytical procedure. A. Sample Collection and Storage Procedure Urine samples were...positives or false-negatives. Next we have carried out a longitudinal study on urine samples obtained from groups of volunteer subjects vaccinated with...sterilization and storage procedures. 2. Developed new, simpler sample preparation techniques including one to handle tissue culture media. 3. Improved on the
A common soil handling technique can generate incorrect estimates of soil biota effects on plants
USDA-ARS?s Scientific Manuscript database
Several plant-soil biota (PSB) studies were recently published in high profile journals that used the suspect “mixed soil sampling” methodology. To explore the extent to which mixing field samples (i.e. employing mixed soil sample designs) can generate erroneous conclusions, we used real data to pa...
Feist, Peter; Hummon, Amanda B.
2015-01-01
Proteins regulate many cellular functions and analyzing the presence and abundance of proteins in biological samples are central focuses in proteomics. The discovery and validation of biomarkers, pathways, and drug targets for various diseases can be accomplished using mass spectrometry-based proteomics. However, with mass-limited samples like tumor biopsies, it can be challenging to obtain sufficient amounts of proteins to generate high-quality mass spectrometric data. Techniques developed for macroscale quantities recover sufficient amounts of protein from milligram quantities of starting material, but sample losses become crippling with these techniques when only microgram amounts of material are available. To combat this challenge, proteomicists have developed micro-scale techniques that are compatible with decreased sample size (100 μg or lower) and still enable excellent proteome coverage. Extraction, contaminant removal, protein quantitation, and sample handling techniques for the microgram protein range are reviewed here, with an emphasis on liquid chromatography and bottom-up mass spectrometry-compatible techniques. Also, a range of biological specimens, including mammalian tissues and model cell culture systems, are discussed. PMID:25664860
Connor, Thomas H; Smith, Jerome P
2016-09-01
At the present time, the method of choice to determine surface contamination of the workplace with antineoplastic and other hazardous drugs is surface wipe sampling and subsequent sample analysis with a variety of analytical techniques. The purpose of this article is to review current methodology for determining the level of surface contamination with hazardous drugs in healthcare settings and to discuss recent advances in this area. In addition it will provide some guidance for conducting surface wipe sampling and sample analysis for these drugs in healthcare settings. Published studies on the use of wipe sampling to measure hazardous drugs on surfaces in healthcare settings drugs were reviewed. These studies include the use of well-documented chromatographic techniques for sample analysis in addition to newly evolving technology that provides rapid analysis of specific antineoplastic. Methodology for the analysis of surface wipe samples for hazardous drugs are reviewed, including the purposes, technical factors, sampling strategy, materials required, and limitations. The use of lateral flow immunoassay (LFIA) and fluorescence covalent microbead immunosorbent assay (FCMIA) for surface wipe sample evaluation is also discussed. Current recommendations are that all healthc a re settings where antineoplastic and other hazardous drugs are handled include surface wipe sampling as part of a comprehensive hazardous drug-safe handling program. Surface wipe sampling may be used as a method to characterize potential occupational dermal exposure risk and to evaluate the effectiveness of implemented controls and the overall safety program. New technology, although currently limited in scope, may make wipe sampling for hazardous drugs more routine, less costly, and provide a shorter response time than classical analytical techniques now in use.
Solid Phase Microextraction and Related Techniques for Drugs in Biological Samples
Moein, Mohammad Mahdi; Said, Rana; Bassyouni, Fatma
2014-01-01
In drug discovery and development, the quantification of drugs in biological samples is an important task for the determination of the physiological performance of the investigated drugs. After sampling, the next step in the analytical process is sample preparation. Because of the low concentration levels of drug in plasma and the variety of the metabolites, the selected extraction technique should be virtually exhaustive. Recent developments of sample handling techniques are directed, from one side, toward automatization and online coupling of sample preparation units. The primary objective of this review is to present the recent developments in microextraction sample preparation methods for analysis of drugs in biological fluids. Microextraction techniques allow for less consumption of solvent, reagents, and packing materials, and small sample volumes can be used. In this review the use of solid phase microextraction (SPME), microextraction in packed sorbent (MEPS), and stir-bar sorbtive extraction (SBSE) in drug analysis will be discussed. In addition, the use of new sorbents such as monoliths and molecularly imprinted polymers will be presented. PMID:24688797
2012-12-01
4.5 Food-grade aluminum foil 4.6 Stainless steel forceps 4.7 Single-edge razor blades 4.8 Teflon (or similar non-contaminating material) cutting...handling PE to avoid cross-contaminating the PE. 6.3 Methylene chloride (pesticide grade) rinsed, stainless steel forceps and scissors are used...3.1 PE is susceptible to contamination from atmospheric and surfaces, and so it must be handled using clean techniques. 3.2 While the formation of
Flexible automated approach for quantitative liquid handling of complex biological samples.
Palandra, Joe; Weller, David; Hudson, Gary; Li, Jeff; Osgood, Sarah; Hudson, Emily; Zhong, Min; Buchholz, Lisa; Cohen, Lucinda H
2007-11-01
A fully automated protein precipitation technique for biological sample preparation has been developed for the quantitation of drugs in various biological matrixes. All liquid handling during sample preparation was automated using a Hamilton MicroLab Star Robotic workstation, which included the preparation of standards and controls from a Watson laboratory information management system generated work list, shaking of 96-well plates, and vacuum application. Processing time is less than 30 s per sample or approximately 45 min per 96-well plate, which is then immediately ready for injection onto an LC-MS/MS system. An overview of the process workflow is discussed, including the software development. Validation data are also provided, including specific liquid class data as well as comparative data of automated vs manual preparation using both quality controls and actual sample data. The efficiencies gained from this automated approach are described.
NASA Astrophysics Data System (ADS)
Rudman, Reuben
1999-06-01
Wiley-VCH: New York, 1998. xxiv + 333 pp. ISBN 0-471-19458-1. $79.95. I would have subtitled this book "All You Ever Wanted To Know about ...Sample Preparation". Although its principal thrust is geared towards the analytical chemist in an X-ray diffraction (XRD) or X-ray fluorescence (XRF) service laboratory, this text will be of use primarily as a reference source in all milieus dealing with undergraduate research projects and advanced laboratory courses in physical and analytical chemistry. It contains dozens of suggestions for preparing randomly oriented small samples of nearly anything. For example, rocks and minerals, soft organics and hard ceramics, radioactive and liquid materials, metals and oils are all treated. As the availability of XRD and XRF equipment has increased, so has the use of these techniques in the teaching schedule. Many undergraduate laboratory and research projects utilizing these methods have been described in the literature and are found in laboratory textbooks. Very often, especially with the increasingly common use of automated computer-controlled instrumentation, sample preparation has become the key experimental technique required for successful data collection. However, it is not always easy to prepare the statistically random distribution of small particles (crystallites) that is required by these methods. A multitude of techniques have been developed over the past 70 years, but many of them have been handed down by word of mouth or are scattered throughout the literature. This book represents an attempt to systematically describe the theory and practice of sample preparation. This excellent guide to the intricacies of sample preparation begins with a description of statistical sampling methods and the principles of grinding techniques. After a discussion of XRF specimen preparation, which includes pressing pellets, fusion methods, crucible selection and handling very small samples, detailed descriptions for handling rocks, minerals, cements, metals, oils, and vegetation [sic] are given. The preparation of XRD samples is described for various diffraction equipment geometries (utilizing both counter and film detectors), including specific information regarding the use of flat specimens and slurries, the use of internal standards, and the effects of crystallite size on the diffraction pattern. Methods for handling ceramics, clays, zeolites, air-sensitive samples, thin films, and plastics are described, along with the special handling requirements for materials to be studied by high-pressure, high-temperature, or low-temperature techniques. One whole chapter is devoted to the equipment used in specimen preparation, including grinders, pulverizers, presses, specimen holders, repair of platinumware, and sources of all types of special equipment. Did you ever want to know where to get a Plattner steel mortar or a micronizing mill or soft-glass capillary tubes with 0.01-mm wall thickness? It's all here in this monograph. The book ends with a good glossary of terms, a general bibliography in addition to the extensive list of references following each of its 9 chapters, and an index. It will be of help in many areas of spectroscopy and analytical chemistry, as well as in XRD and XRF analyses.
2012-07-01
use of molecular biological techniques (MBTs) has allowed microbial ecologists and environmental engineers to determine microbial community...metabolic genes). The most common approaches used in bioremediation research are those based on the polymerase chain reaction (PCR) amplification of... bioremediation . Because of its sensitivity compared to direct hybridization/probing, PCR is increasingly used to analyze groundwater samples and soil samples
NASA Technical Reports Server (NTRS)
Younse, Paulo J.; Dicicco, Matthew A.; Morgan, Albert R.
2012-01-01
A report describes the PLuto (programmable logic) Mars Technology Rover, a mid-sized FIDO (field integrated design and operations) class rover with six fully drivable and steerable cleated wheels, a rocker-bogey suspension, a pan-tilt mast with panorama and navigation stereo camera pairs, forward and rear stereo hazcam pairs, internal avionics with motor drivers and CPU, and a 5-degrees-of-freedom robotic arm. The technology rover was integrated with an arm-mounted percussive coring tool, microimager, and sample handling encapsulation containerization subsystem (SHEC). The turret of the arm contains a percussive coring drill and microimager. The SHEC sample caching system mounted to the rover body contains coring bits, sample tubes, and sample plugs. The coring activities performed in the field provide valuable data on drilling conditions for NASA tasks developing and studying coring technology. Caching of samples using the SHEC system provide insight to NASA tasks investigating techniques to store core samples in the future.
It's Time to Develop a New "Draft Test Protocol" for a Mars Sample Return Mission (or Two…).
Rummel, John D; Kminek, Gerhard
2018-04-01
The last time NASA envisioned a sample return mission from Mars, the development of a protocol to support the analysis of the samples in a containment facility resulted in a "Draft Test Protocol" that outlined required preparations "for the safe receiving, handling, testing, distributing, and archiving of martian materials here on Earth" (Rummel et al., 2002 ). This document comprised a specific protocol to be used to conduct a biohazard test for a returned martian sample, following the recommendations of the Space Studies Board of the US National Academy of Sciences. Given the planned launch of a sample-collecting and sample-caching rover (Mars 2020) in 2 years' time, and with a sample return planned for the end of the next decade, it is time to revisit the Draft Test Protocol to develop a sample analysis and biohazard test plan to meet the needs of these future missions. Key Words: Biohazard detection-Mars sample analysis-Sample receiving facility-Protocol-New analytical techniques-Robotic sample handling. Astrobiology 18, 377-380.
Yoshida, Jin; Koda, Shigeki; Nishida, Shozo; Yoshida, Toshiaki; Miyajima, Keiko; Kumagai, Shinji
2011-03-01
The aim of the present study was to evaluate the measurement of contamination by antineoplastic drugs for safer handling of such drugs by medical workers. We investigated the relationship between the contamination level of antineoplastic drugs and the conditions of their handling. Air samples and wipe samples were collected from equipment in the preparation rooms of five hospitals (hospitals A-E). These samples were subjected to measurement of the amounts of cyclophosphamide (CPA), fluorouracil (5FU), gemcitabine (GEM), and platinum-containing drugs (Pt). Twenty-four-hour urine samples were collected from the pharmacists who handled or audited, the antineoplastic drugs were analyzed for CPA and Pt. Pt was detected from air samples inside BSC in hospital B. Antineoplastic drugs were detected from wipe samples of the BSC in hospitals A, B, D, and E and of other equipment in the preparation rooms in hospitals A, B, C, and D. Cyclophosphamide and 5FU were detected from wipe samples of the air-conditioner filter in hospital A, and CPA was detected from that in hospital D. Cyclophosphamide was detected from urine samples of workers in hospitals B, D, and E. The contamination level of antineoplastic drugs was suggested to be related with the amount of drugs handled, cleaning methods of the equipment, and the skill level of the technique of maintaining negative pressure inside a vial. In order to reduce the contamination and exposure to antineoplastic drugs in the hospital work environment very close to zero, comprehensive safety precautions, including adequate mixing and cleaning methods was required in addition to BSC and closed system device.
Techniques for Nonterminal Blood Sampling in Black-Tailed Prairie Dogs (Cynomys ludovicianus).
Head, Valerie; Eshar, David; Nau, Melissa R
2017-03-01
Black-tailed prairie dogs (Cynomys ludovicianus) are used as an animal model for research on gallbladder stones and several infectious diseases. A comprehensive, instructive resource regarding the appropriate techniques for venipuncture and collection of nonterminal blood samples in this species has not yet been published. Blood samples (1 mL or larger) were readily obtained from the jugular vein, femoral vein, or cranial vena cava, whereas peripheral sites, such as the cephalic vein, saphenous vein, and tarsal vein, mainly were useful for obtaining smaller volumes. The detailed and illustrated information presented here can aid clinicians and researchers in performing venipuncture, anesthesia, and handling of this species.
sideSPIM - selective plane illumination based on a conventional inverted microscope.
Hedde, Per Niklas; Malacrida, Leonel; Ahrar, Siavash; Siryaporn, Albert; Gratton, Enrico
2017-09-01
Previously described selective plane illumination microscopy techniques typically offset ease of use and sample handling for maximum imaging performance or vice versa . Also, to reduce cost and complexity while maximizing flexibility, it is highly desirable to implement light sheet microscopy such that it can be added to a standard research microscope instead of setting up a dedicated system. We devised a new approach termed sideSPIM that provides uncompromised imaging performance and easy sample handling while, at the same time, offering new applications of plane illumination towards fluidics and high throughput 3D imaging of multiple specimen. Based on an inverted epifluorescence microscope, all of the previous functionality is maintained and modifications to the existing system are kept to a minimum. At the same time, our implementation is able to take full advantage of the speed of the employed sCMOS camera and piezo stage to record data at rates of up to 5 stacks/s. Additionally, sample handling is compatible with established methods and switching magnification to change the field of view from single cells to whole organisms does not require labor intensive adjustments of the system.
Determination of Residual Chlorine and Turbidity in Drinking Water. Instructor's Manual.
ERIC Educational Resources Information Center
Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.
This instructor's guide presents analytical methods for residual chlorine and turbidity. Topics include sample handling, permissable concentration levels, substitution of residual chlorine for bacteriological work, public notification, and the required analytical techniques to determine residual chlorine and turbidity. This publication is intended…
Determination of Residual Chlorine and Turbidity in Drinking Water. Student Manual.
ERIC Educational Resources Information Center
Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.
This student's manual covers analytical methods for residual chlorine and turbidity. Topics include sample handling, permissable concentration levels, substitution of residual chlorine for bacteriological work, public notification, and the required analytical techniques to determine residual chlorine and turbidity. The publication is intended for…
Water Quality & Pollutant Source Monitoring: Field and Laboratory Procedures. Training Manual.
ERIC Educational Resources Information Center
Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.
This training manual presents material on techniques and instrumentation used to develop data in field monitoring programs and related laboratory operations concerned with water quality and pollution monitoring. Topics include: collection and handling of samples; bacteriological, biological, and chemical field and laboratory methods; field…
Manipulation of biological samples using micro and nano techniques.
Castillo, Jaime; Dimaki, Maria; Svendsen, Winnie Edith
2009-01-01
The constant interest in handling, integrating and understanding biological systems of interest for the biomedical field, the pharmaceutical industry and the biomaterial researchers demand the use of techniques that allow the manipulation of biological samples causing minimal or no damage to their natural structure. Thanks to the advances in micro- and nanofabrication during the last decades several manipulation techniques offer us the possibility to image, characterize and manipulate biological material in a controlled way. Using these techniques the integration of biomaterials with remarkable properties with physical transducers has been possible, giving rise to new and highly sensitive biosensing devices. This article reviews the different techniques available to manipulate and integrate biological materials in a controlled manner either by sliding them along a surface (2-D manipulation), by grapping them and moving them to a new position (3-D manipulation), or by manipulating and relocating them applying external forces. The advantages and drawbacks are mentioned together with examples that reflect the state of the art of manipulation techniques for biological samples (171 references).
The multiple imputation method: a case study involving secondary data analysis.
Walani, Salimah R; Cleland, Charles M
2015-05-01
To illustrate with the example of a secondary data analysis study the use of the multiple imputation method to replace missing data. Most large public datasets have missing data, which need to be handled by researchers conducting secondary data analysis studies. Multiple imputation is a technique widely used to replace missing values while preserving the sample size and sampling variability of the data. The 2004 National Sample Survey of Registered Nurses. The authors created a model to impute missing values using the chained equation method. They used imputation diagnostics procedures and conducted regression analysis of imputed data to determine the differences between the log hourly wages of internationally educated and US-educated registered nurses. The authors used multiple imputation procedures to replace missing values in a large dataset with 29,059 observations. Five multiple imputed datasets were created. Imputation diagnostics using time series and density plots showed that imputation was successful. The authors also present an example of the use of multiple imputed datasets to conduct regression analysis to answer a substantive research question. Multiple imputation is a powerful technique for imputing missing values in large datasets while preserving the sample size and variance of the data. Even though the chained equation method involves complex statistical computations, recent innovations in software and computation have made it possible for researchers to conduct this technique on large datasets. The authors recommend nurse researchers use multiple imputation methods for handling missing data to improve the statistical power and external validity of their studies.
USDA-ARS?s Scientific Manuscript database
As sample preparation and analytical techniques have improved, data handling has become the main limitation in automated high-throughput analysis of targeted chemicals in many applications. Conventional chromatographic peak integration functions rely on complex software and settings, but untrustwor...
An investigation of the source of air Ar contamination in KAr dating
Mussett, A.E.; Brent, Dalrymple G.
1968-01-01
Precision of young KAr ages is limited by air argon contamination. A series of experiments in which the exposure of basalt and sanidine samples to air argon was controlled, shows that most of the air contamination does not arise in the laboratory. Because of this, it seems unlikely that air argon contamination can be significantly reduced by special sample handling and preparation techniques. ?? 1968.
NASA Astrophysics Data System (ADS)
Miller, David P.; Bonaccorsi, Rosalba; Davis, Kiel
2008-10-01
Mars Astrobiology Research and Technology Experiment (MARTE) investigators used an automated drill and sample processing hardware to detect and categorize life-forms found in subsurface rock at Río Tinto, Spain. For the science to be successful, it was necessary for the biomass from other sources -- whether from previously processed samples (cross contamination) or the terrestrial environment (forward contamination) -- to be insignificant. The hardware and practices used in MARTE were designed around this problem. Here, we describe some of the design issues that were faced and classify them into problems that are unique to terrestrial tests versus problems that would also exist for a system that was flown to Mars. Assessment of the biomass at various stages in the sample handling process revealed mixed results; the instrument design seemed to minimize cross contamination, but contamination from the surrounding environment sometimes made its way onto the surface of samples. Techniques used during the MARTE Río Tinto project, such as facing the sample, appear to remove this environmental contamination without introducing significant cross contamination from previous samples.
Miller, David P; Bonaccorsi, Rosalba; Davis, Kiel
2008-10-01
Mars Astrobiology Research and Technology Experiment (MARTE) investigators used an automated drill and sample processing hardware to detect and categorize life-forms found in subsurface rock at Río Tinto, Spain. For the science to be successful, it was necessary for the biomass from other sources--whether from previously processed samples (cross contamination) or the terrestrial environment (forward contamination)-to be insignificant. The hardware and practices used in MARTE were designed around this problem. Here, we describe some of the design issues that were faced and classify them into problems that are unique to terrestrial tests versus problems that would also exist for a system that was flown to Mars. Assessment of the biomass at various stages in the sample handling process revealed mixed results; the instrument design seemed to minimize cross contamination, but contamination from the surrounding environment sometimes made its way onto the surface of samples. Techniques used during the MARTE Río Tinto project, such as facing the sample, appear to remove this environmental contamination without introducing significant cross contamination from previous samples.
sideSPIM – selective plane illumination based on a conventional inverted microscope
Hedde, Per Niklas; Malacrida, Leonel; Ahrar, Siavash; Siryaporn, Albert; Gratton, Enrico
2017-01-01
Previously described selective plane illumination microscopy techniques typically offset ease of use and sample handling for maximum imaging performance or vice versa. Also, to reduce cost and complexity while maximizing flexibility, it is highly desirable to implement light sheet microscopy such that it can be added to a standard research microscope instead of setting up a dedicated system. We devised a new approach termed sideSPIM that provides uncompromised imaging performance and easy sample handling while, at the same time, offering new applications of plane illumination towards fluidics and high throughput 3D imaging of multiple specimen. Based on an inverted epifluorescence microscope, all of the previous functionality is maintained and modifications to the existing system are kept to a minimum. At the same time, our implementation is able to take full advantage of the speed of the employed sCMOS camera and piezo stage to record data at rates of up to 5 stacks/s. Additionally, sample handling is compatible with established methods and switching magnification to change the field of view from single cells to whole organisms does not require labor intensive adjustments of the system. PMID:29026679
Workshop on Analysis of Returned Comet Nucleus Samples
NASA Technical Reports Server (NTRS)
1989-01-01
This volume contains abstracts that were accepted by the Program Committee for presentation at the workshop on the analysis of returned comet nucleus samples held in Milpitas, California, January 16 to 18, 1989. The abstracts deal with the nature of cometary ices, cryogenic handling and sampling equipment, origin and composition of samples, and spectroscopic, thermal and chemical processing methods of cometary nuclei. Laboratory simulation experimental results on dust samples are reported. Some results obtained from Halley's comet are also included. Microanalytic techniques for examining trace elements of cometary particles, synchrotron x ray fluorescence and instrument neutron activation analysis (INAA), are presented.
Hybrid real-code ant colony optimisation for constrained mechanical design
NASA Astrophysics Data System (ADS)
Pholdee, Nantiwat; Bureerat, Sujin
2016-01-01
This paper proposes a hybrid meta-heuristic based on integrating a local search simplex downhill (SDH) method into the search procedure of real-code ant colony optimisation (ACOR). This hybridisation leads to five hybrid algorithms where a Monte Carlo technique, a Latin hypercube sampling technique (LHS) and a translational propagation Latin hypercube design (TPLHD) algorithm are used to generate an initial population. Also, two numerical schemes for selecting an initial simplex are investigated. The original ACOR and its hybrid versions along with a variety of established meta-heuristics are implemented to solve 17 constrained test problems where a fuzzy set theory penalty function technique is used to handle design constraints. The comparative results show that the hybrid algorithms are the top performers. Using the TPLHD technique gives better results than the other sampling techniques. The hybrid optimisers are a powerful design tool for constrained mechanical design problems.
Pearson, Kristen Nicole; Kendall, William L.; Winkelman, Dana L.; Persons, William R.
2016-01-01
A key component of many monitoring programs for special status species involves capture and handling of individuals as part of capture-recapture efforts for tracking population health and demography. Minimizing negative impacts from sampling, such as through reduced handling, aids prevention of negative impacts on species from monitoring efforts. Using simulation analyses, we found that long-term population monitoring techniques, requiring physical capture (i.e. hoop-net sampling), can be reduced and supplemented with passive detections (i.e. PIT tag antenna array detections) without negatively affecting estimates of adult humpback chub (HBC; Gila cypha) survival (S) and skipped spawning probabilities (γ' = spawner transitions to a skipped spawner, γ′ = skipped spawner remains a skipped spawner). Based on our findings of the array’s in situ detection efficiency (0.42), estimability of such demographic parameters would improve over hoop-netting alone. In addition, the array provides insight into HBC population dynamics and movement patterns outside of traditional sampling periods. However, given current timing of sampling efforts, spawner abundance estimates were negatively biased when hoop-netting was reduced, suggesting not all spawning HBC are present during the current sampling events. Despite this, our findings demonstrate that PIT tag antenna arrays, even with moderate potential detectability, may allow for reduced handling of special status species while also offering potentially more efficient monitoring strategies, especially if ideal timing of sampling can be determined.
DOE Office of Scientific and Technical Information (OSTI.GOV)
C.J. Miller; G. Elias; N.C. Schmitt
2010-06-01
High performance liquid chromatography and gas chromatography techniques are well documented and widely used for the detection of trace explosives from organic solvents. These techniques were modified to specifically identify and quantify explosives extracted from various materials taken from people who had recently handled explosives. Documented techniques were modified to specifically detect and quantify RDX, TNT, and PETN from denim, colored flannel, vinyl, and canvas extracted in methanol using no sample cleanup prior to analysis. The methanol extracts were injected directly into several different column types and analyzed by HPLC-UV and/or GC-ECD. This paper describes general screening methods that weremore » used to determine the presence of explosives in unknown samples and techniques that have been optimized for quantification of each explosive from the substrate extracts.« less
Accelerating root system phenotyping of seedlings through a computer-assisted processing pipeline.
Dupuy, Lionel X; Wright, Gladys; Thompson, Jacqueline A; Taylor, Anna; Dekeyser, Sebastien; White, Christopher P; Thomas, William T B; Nightingale, Mark; Hammond, John P; Graham, Neil S; Thomas, Catherine L; Broadley, Martin R; White, Philip J
2017-01-01
There are numerous systems and techniques to measure the growth of plant roots. However, phenotyping large numbers of plant roots for breeding and genetic analyses remains challenging. One major difficulty is to achieve high throughput and resolution at a reasonable cost per plant sample. Here we describe a cost-effective root phenotyping pipeline, on which we perform time and accuracy benchmarking to identify bottlenecks in such pipelines and strategies for their acceleration. Our root phenotyping pipeline was assembled with custom software and low cost material and equipment. Results show that sample preparation and handling of samples during screening are the most time consuming task in root phenotyping. Algorithms can be used to speed up the extraction of root traits from image data, but when applied to large numbers of images, there is a trade-off between time of processing the data and errors contained in the database. Scaling-up root phenotyping to large numbers of genotypes will require not only automation of sample preparation and sample handling, but also efficient algorithms for error detection for more reliable replacement of manual interventions.
Study of sample drilling techniques for Mars sample return missions
NASA Technical Reports Server (NTRS)
Mitchell, D. C.; Harris, P. T.
1980-01-01
To demonstrate the feasibility of acquiring various surface samples for a Mars sample return mission the following tasks were performed: (1) design of a Mars rover-mounted drill system capable of acquiring crystalline rock cores; prediction of performance, mass, and power requirements for various size systems, and the generation of engineering drawings; (2) performance of simulated permafrost coring tests using a residual Apollo lunar surface drill, (3) design of a rock breaker system which can be used to produce small samples of rock chips from rocks which are too large to return to Earth, but too small to be cored with the Rover-mounted drill; (4)design of sample containers for the selected regolith cores, rock cores, and small particulate or rock samples; and (5) design of sample handling and transfer techniques which will be required through all phase of sample acquisition, processing, and stowage on-board the Earth return vehicle. A preliminary design of a light-weight Rover-mounted sampling scoop was also developed.
Chemical analysis of acoustically levitated drops by Raman spectroscopy.
Tuckermann, Rudolf; Puskar, Ljiljana; Zavabeti, Mahta; Sekine, Ryo; McNaughton, Don
2009-07-01
An experimental apparatus combining Raman spectroscopy with acoustic levitation, Raman acoustic levitation spectroscopy (RALS), is investigated in the field of physical and chemical analytics. Whereas acoustic levitation enables the contactless handling of microsized samples, Raman spectroscopy offers the advantage of a noninvasive method without complex sample preparation. After carrying out some systematic tests to probe the sensitivity of the technique to drop size, shape, and position, RALS has been successfully applied in monitoring sample dilution and preconcentration, evaporation, crystallization, an acid-base reaction, and analytes in a surface-enhanced Raman spectroscopy colloidal suspension.
X-ray diffraction on radioactive materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schiferl, D.; Roof, R.B.
1978-01-01
X-ray diffraction studies on radioactive materials are discussed with the aim of providing a guide to new researchers in the field. Considerable emphasis is placed on the safe handling and loading of not-too-exotic samples. Special considerations such as the problems of film blackening by the gamma rays and changes induced by the self-irradiation of the sample are covered. Some modifications of common diffraction techniques are presented. Finally, diffraction studies on radioactive samples under extreme conditions are discussed, with primary emphasis on high-pressure studies involving diamond-anvil cells.
Pérez-Zárate, Pamela; Aragón-Piña, Antonio; Soria-Guerra, Ruth Elena; González-Amaro, Ana María; Pérez-Urizar, José; Pérez-González, Luis Fernando; Martinez-Gutierrez, Fidel
2015-11-01
To determinate the significance of risk factors with the presence of biofilm on catheters of patients attended at tertiary hospital cares. A total of 126 patients were included, data collection by observing the handling of the CVC, clinical history and microbiological isolation methods of CVCs tips (Roll-plate, sonication and scanning electron microscopy) were evaluated. Certain factors, such as the lack of proper hand washing, the use of primary barriers and preparing medications in the same hospital service, showed an important relationship between biofilm formation in CVCs. The sonication method presented that most of the samples had isolation of multispecies 29 samples (64%); in contrast with the roll-plate method, just one sample (3%) was isolated. The importance of the strict aseptic techniques of insertion and of the handlings of CVC was highlighted, the failure of both techniques was related to the biofilm formation and was evidenced using the scanning electron microscopy. Since this tool is not available in most hospitals, we present the correlation of those evidences with other standard microbiological methods and risk factors, which are necessary for the sensible detection of the different steps of the biofilm formation on CVC and their correct interpretation with clinical evidences. Copyright © 2015 Elsevier Ltd. All rights reserved.
Effects of surgically implanted transmitters on reproduction and survival in mallards
Sheppard, Jennifer; Arnold, Todd W.; Amundson, Courtney L.; Klee, David
2017-01-01
Abdominally implanted radiotransmitters have been widely used in studies of waterbird ecology; however, the longer handling times and invasiveness of surgical implantation raise important concerns about animal welfare and potential effects on data quality. Although it is difficult to assess effects of handling and marking wild animals by comparing them with unmarked controls, insights can often be obtained by evaluating variation in handling or marking techniques. Here, we used data from 243 female mallards (Anas platyrhynchos) and mallard–grey duck hybrids (A. platyrhynchos × A. superciliosa) equipped with fully encapsulated abdominally implanted radiotransmitters from 2 study sites in New Zealand during 2014–2015 to assess potential marking effects. We evaluated survival, dispersal, and reproductive effort (e.g., breeding propensity, nest initiation date, clutch size) in response to 3 different attributes of handling duration and procedures: 1) processing time, including presurgery banding, measurements, and blood sampling of unanaesthetized birds; 2) surgery time from initiation to cessation of anesthetic; and 3) total holding time from first capture until release. We found no evidence that female survival, dispersal probability, or reproductive effort were negatively affected by holding, processing, or surgery time and concluded that we collected reliable data without compromising animal welfare. Our results support previous research that techniques using fully encapsulated abdominal-implant radiotransmitters are suitable to enable researchers to obtain reliable estimates of reproductive performance and survival.
Handling imbalance data in churn prediction using combined SMOTE and RUS with bagging method
NASA Astrophysics Data System (ADS)
Pura Hartati, Eka; Adiwijaya; Arif Bijaksana, Moch
2018-03-01
Customer churn has become a significant problem and also a challenge for Telecommunication company such as PT. Telkom Indonesia. It is necessary to evaluate whether the big problems of churn customer and the company’s managements will make appropriate strategies to minimize the churn and retaining the customer. Churn Customer data which categorized churn Atas Permintaan Sendiri (APS) in this Company is an imbalance data, and this issue is one of the challenging tasks in machine learning. This study will investigate how is handling class imbalance in churn prediction using combined Synthetic Minority Over-Sampling (SMOTE) and Random Under-Sampling (RUS) with Bagging method for a better churn prediction performance’s result. The dataset that used is Broadband Internet data which is collected from Telkom Regional 6 Kalimantan. The research firstly using data preprocessing to balance the imbalanced dataset and also to select features by sampling technique SMOTE and RUS, and then building churn prediction model using Bagging methods and C4.5.
Behavioural cues of reproductive status in seahorses Hippocampus abdominalis.
Whittington, C M; Musolf, K; Sommer, S; Wilson, A B
2013-07-01
A method is described to assess the reproductive status of male Hippocampus abdominalis on the basis of behavioural traits. The non-invasive nature of this technique minimizes handling stress and reduces sampling requirements for experimental work. It represents a useful tool to assist researchers in sample collection for studies of reproduction and development in viviparous syngnathids, which are emerging as important model species. © 2013 The Authors. Journal of Fish Biology © 2013 The Fisheries Society of the British Isles.
Ivahnenko, T.; Szabo, Z.; Gibs, J.
2001-01-01
Ground-water sampling techniques were modified to reduce random low-level contamination during collection of filtered water samples for determination of trace-element concentrations. The modified sampling techniques were first used in New Jersey by the US Geological Survey in 1994 along with inductively coupled plasma-mass spectrometry (ICP-MS) analysis to determine the concentrations of 18 trace elements at the one microgram-per-liter (μg/L) level in the oxic water of the unconfined sand and gravel Kirkwood-Cohansey aquifer system. The revised technique tested included a combination of the following: collection of samples (1) with flow rates of about 2L per minute, (2) through acid-washed single-use disposable tubing and (3) a single-use disposable 0.45-μm pore size capsule filter, (4) contained within portable glove boxes, (5) in a dedicated clean sampling van, (6) only after turbidity stabilized at values less than 2 nephelometric turbidity units (NTU), when possible. Quality-assurance data, obtained from equipment blanks and split samples, indicated that trace element concentrations, with the exception of iron, chromium, aluminum, and zinc, measured in the samples collected in 1994 were not subject to random contamination at 1μg/L.Results from samples collected in 1994 were compared to those from samples collected in 1991 from the same 12 PVC-cased observation wells using the available sampling and analytical techniques at that time. Concentrations of copper, lead, manganese and zinc were statistically significantly lower in samples collected in 1994 than in 1991. Sampling techniques used in 1994 likely provided trace-element data that represented concentrations in the aquifer with less bias than data from 1991 when samples were collected without the same degree of attention to sample handling.
Experimental aspect of solid-state nuclear magnetic resonance studies of biomaterials such as bones.
Singh, Chandan; Rai, Ratan Kumar; Sinha, Neeraj
2013-01-01
Solid-state nuclear magnetic resonance (SSNMR) spectroscopy is increasingly becoming a popular technique to probe micro-structural details of biomaterial such as bone with pico-meter resolution. Due to high-resolution structural details probed by SSNMR methods, handling of bone samples and experimental protocol are very crucial aspects of study. We present here first report of the effect of various experimental protocols and handling methods of bone samples on measured SSNMR parameters. Various popular SSNMR experiments were performed on intact cortical bone sample collected from fresh animal, immediately after removal from animal systems, and results were compared with bone samples preserved in different conditions. We find that the best experimental conditions for SSNMR parameters of bones correspond to preservation at -20 °C and in 70% ethanol solution. Various other SSNMR parameters were compared corresponding to different experimental conditions. Our study has helped in finding best experimental protocol for SSNMR studies of bone. This study will be of further help in the application of SSNMR studies on large bone disease related animal model systems for statistically significant results. © 2013 Elsevier Inc. All rights reserved.
Alternative Constraint Handling Technique for Four-Bar Linkage Path Generation
NASA Astrophysics Data System (ADS)
Sleesongsom, S.; Bureerat, S.
2018-03-01
This paper proposes an extension of a new concept for path generation from our previous work by adding a new constraint handling technique. The propose technique was initially designed for problems without prescribed timing by avoiding the timing constraint, while remain constraints are solving with a new constraint handling technique. The technique is one kind of penalty technique. The comparative study is optimisation of path generation problems are solved using self-adaptive population size teaching-learning based optimization (SAP-TLBO) and original TLBO. In this study, two traditional path generation test problem are used to test the proposed technique. The results show that the new technique can be applied with the path generation problem without prescribed timing and gives better results than the previous technique. Furthermore, SAP-TLBO outperforms the original one.
Monolithic methacrylate packed 96-tips for high throughput bioanalysis.
Altun, Zeki; Skoglund, Christina; Abdel-Rehim, Mohamed
2010-04-16
In the pharmaceutical industry the growing number of samples to be analyzed requires high throughput and fully automated analytical techniques. Commonly used sample-preparation methods are solid-phase extraction (SPE), liquid-liquid extraction (LLE) and protein precipitation. In this paper we will discus a new sample-preparation technique based on SPE for high throughput drug extraction developed and used by our group. This new sample-preparation method is based on monolithic methacrylate polymer as packing sorbent for 96-tip robotic device. Using this device a 96-well plate could be handled in 2-4min. The key aspect of the monolithic phase is that monolithic material can offer both good binding capacity and low back-pressure properties compared to e.g. silica phases. The present paper presents the successful application of monolithic 96-tips and LC-MS/MS by the sample preparation of busulphan, rescovitine, metoprolol, pindolol and local anaesthetics from human plasma samples and cyklophosphamid from mice blood samples. Copyright 2009 Elsevier B.V. All rights reserved.
A wall-free climate unit for acoustic levitators.
Schlegel, M C; Wenzel, K-J; Sarfraz, A; Panne, U; Emmerling, F
2012-05-01
Acoustic levitation represents the physical background of trapping a sample in a standing acoustic wave with no contact to the wave generating device. For the last three decades, sample holders based on this effect have been commonly used for contact free handling of samples coupled with a number of analytical techniques. In this study, a wall-free climate unit is presented, which allows the control of the environmental conditions of suspended samples. The insulation is based on a continuous cold/hot gas flow around the sample and thus does not require any additional isolation material. This provides a direct access to the levitated sample and circumvents any influence of the climate unit material to the running analyses.
A wall-free climate unit for acoustic levitators
NASA Astrophysics Data System (ADS)
Schlegel, M. C.; Wenzel, K.-J.; Sarfraz, A.; Panne, U.; Emmerling, F.
2012-05-01
Acoustic levitation represents the physical background of trapping a sample in a standing acoustic wave with no contact to the wave generating device. For the last three decades, sample holders based on this effect have been commonly used for contact free handling of samples coupled with a number of analytical techniques. In this study, a wall-free climate unit is presented, which allows the control of the environmental conditions of suspended samples. The insulation is based on a continuous cold/hot gas flow around the sample and thus does not require any additional isolation material. This provides a direct access to the levitated sample and circumvents any influence of the climate unit material to the running analyses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barber, F.H.; Borek, T.T.; Christopher, J.Z.
1997-12-01
Analytical and Process Chemistry (A&PC) support is essential to the high-level waste vitrification campaign at the West Valley Demonstration Project (WVDP). A&PC characterizes the waste, providing information necessary to formulate the recipe for the target radioactive glass product. High-level waste (HLW) samples are prepared and analyzed in the analytical cells (ACs) and Sample Storage Cell (SSC) on the third floor of the main plant. The high levels of radioactivity in the samples require handling them in the shielded cells with remote manipulators. The analytical hot cells and third floor laboratories were refurbished to ensure optimal uninterrupted operation during the vitrificationmore » campaign. New and modified instrumentation, tools, sample preparation and analysis techniques, and equipment and training were required for A&PC to support vitrification. Analytical Cell Mockup Units (ACMUs) were designed to facilitate method development, scientist and technician training, and planning for analytical process flow. The ACMUs were fabricated and installed to simulate the analytical cell environment and dimensions. New techniques, equipment, and tools could be evaluated m in the ACMUs without the consequences of generating or handling radioactive waste. Tools were fabricated, handling and disposal of wastes was addressed, and spatial arrangements for equipment were refined. As a result of the work at the ACMUs the remote preparation and analysis methods and the equipment and tools were ready for installation into the ACs and SSC m in July 1995. Before use m in the hot cells, all remote methods had been validated and four to eight technicians were trained on each. Fine tuning of the procedures has been ongoing at the ACs based on input from A&PC technicians. Working at the ACs presents greater challenges than had development at the ACMUs. The ACMU work and further refinements m in the ACs have resulted m in a reduction m in analysis turnaround time (TAT).« less
Optofluidic cellular immunofunctional analysis by localized surface plasmon resonance
NASA Astrophysics Data System (ADS)
Kurabayashi, Katsuo; Oh, Bo-Ram
2014-08-01
Cytokine secretion assays provide the means to quantify intercellular-signaling proteins secreted by blood immune cells. These assays allow researchers and clinicians to obtain valuable information on the immune status of the donor. Previous studies have demonstrated that localized surface plasmon resonance (LSPR) effects enable label-free, real-time biosensing on a nanostructured metallic surface with simple optics and sensing tunability. However, limited sensitivity coupled with a lack of sample handling capability makes it challenging to implement LSPR biosensing in cellular functional immunoanalysis based on cytokine secretion assay. This paper describes our recent progress towards full development of a label-free LSPR biosensing technique to detect cell-secreted tumor necrosis factor (TNF)-α cytokines in clinical blood samples. We integrate LSPR bionanosensors in an optofluidic platform capable of handling target immune cells in a microfluidic chamber while readily permitting optical access for cytokine detection.
Gehre, Matthias; Renpenning, Julian; Gilevska, Tetyana; Qi, Haiping; Coplen, Tyler B.; Meijer, Harro A.J.; Brand, Willi A.; Schimmelmann, Arndt
2015-01-01
The high temperature conversion (HTC) technique using an elemental analyzer with a glassy carbon tube and filling (temperature conversion/elemental analysis, TC/EA) is a widely used method for hydrogen isotopic analysis of water and many solid and liquid organic samples with analysis by isotope-ratio mass spectrometry (IRMS). However, the TC/EA IRMS method may produce inaccurate δ2H results, with values deviating by more than 20 mUr (milliurey = 0.001 = 1‰) from the true value for some materials. We show that a single-oven, chromium-filled elemental analyzer coupled to an IRMS substantially improves the measurement quality and reliability for hydrogen isotopic compositions of organic substances (Cr-EA method). Hot chromium maximizes the yield of molecular hydrogen in a helium carrier gas by irreversibly and quantitatively scavenging all reactive elements except hydrogen. In contrast, under TC/EA conditions, heteroelements like nitrogen or chlorine (and other halogens) can form hydrogen cyanide (HCN) or hydrogen chloride (HCl) and this can cause isotopic fractionation. The Cr-EA technique thus expands the analytical possibilities for on-line hydrogen-isotope measurements of organic samples significantly. This method yielded reproducibility values (1-sigma) for δ2H measurements on water and caffeine samples of better than 1.0 and 0.5 mUr, respectively. To overcome handling problems with water as the principal calibration anchor for hydrogen isotopic measurements, we have employed an effective and simple strategy using reference waters or other liquids sealed in silver-tube segments. These crimped silver tubes can be employed in both the Cr-EA and TC/EA techniques. They simplify considerably the normalization of hydrogen-isotope measurement data to the VSMOW-SLAP (Vienna Standard Mean Ocean Water-Standard Light Antarctic Precipitation) scale, and their use improves accuracy of the data by eliminating evaporative loss and associated isotopic fractionation while handling water as a bulk sample. The calibration of organic samples, commonly having high δ2H values, will benefit from the availability of suitably 2H-enriched reference waters, extending the VSMOW-SLAP scale above zero.
NASA Astrophysics Data System (ADS)
Bhattacharjee, Sudipta; Deb, Debasis
2016-07-01
Digital image correlation (DIC) is a technique developed for monitoring surface deformation/displacement of an object under loading conditions. This method is further refined to make it capable of handling discontinuities on the surface of the sample. A damage zone is referred to a surface area fractured and opened in due course of loading. In this study, an algorithm is presented to automatically detect multiple damage zones in deformed image. The algorithm identifies the pixels located inside these zones and eliminate them from FEM-DIC processes. The proposed algorithm is successfully implemented on several damaged samples to estimate displacement fields of an object under loading conditions. This study shows that displacement fields represent the damage conditions reasonably well as compared to regular FEM-DIC technique without considering the damage zones.
Becker, P.H.; Voigt, C.C.; Arnold, J.M.; Nagel, R.
2006-01-01
We describe a non-invasive technique to obtain blood samples from incubating birds without trapping and handling. A larval instar of the blood-sucking bug Dipetalogaster maximus (Heteroptera) was put in a hollowed artificial egg which was placed in a common tern Sterna hirundo) nest. A gauze-covered hole in the egg allowed the bug to draw blood from the brood patch of breeding adults. We successfully collected 68 blood samples of sufficient amount (median=187 ??l). The daily success rate was highest during the early breeding season and averaged 34% for all trials. We could not detect any visible response by the incubating bird to the sting of the bug. This technique allows for non-invasive blood collection from bird species of various sizes without disturbance. ?? Dt. Ornithologen-Gesellschaft e.V. 2005.
Chemoiwa, R K; Mukthar, V K; Maranga, A K; Kulei, S J
2014-10-01
To analyse the infection prevention practices in handling of injections by nurses in Rift Valley Provincial Hospital in Kenya. A cross-sectional observational study. Rift Valley Provincial hospital which is a level five health facility situated in Nakuru County, Kenya. A sample of 386 injection procedures attributed to the nurses in Rift Valley Provincial Hospital was considered for this study. The study established that among all the injections administered in this study, 43.7% (386) adhered to aseptic techniques. Over seventy five percent (76.9%, n = 386) of the observed injections procedures did not involve the hand-washing, 53.4% (n = 206) did not involve swabbing of a vial rubber cap with alcohol swabs and 95.1%(n = 263) involved using of multidose drug in more than one designated patient. Over ninety five percent (95.6%, n = 364) of the observed procedures involved use of sterile the syringe bit of the devices only while the rest used either clean or contaminated syringes. Around forty percent (42.2%, n = 316) of the injections preparation was done elsewhere (not at the patient bedside) before administration. Slightly over thirty five percent (36.6%, n = 386) of the injections were administered immediately upon reconstitution(at the right time). The study also established the use of aseptic techniques to reconstitute and administer was significantly related to the number of nurses to patients ratio per shift (X2(1) = 3.5: p = 0.04). The findings of this study indicate that patient safety in public hospital is still relatively low. The adherence to basic infection prevention procedures/aseptic techniques in handling of injections by health workers is still a concern. The adherence to aseptic techniques in handling injections is significantly associated with the nurses to patients ratios. Therefore, it is imperative to improve nurse to patient ratio in public health facilities in Kenya.
7 CFR 27.20 - Drawing and handling of samples of cotton; inspection of bales.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 2 2014-01-01 2014-01-01 false Drawing and handling of samples of cotton; inspection... STANDARDS AND STANDARD CONTAINER REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.20 Drawing and handling of samples of cotton; inspection of bales. One...
7 CFR 27.20 - Drawing and handling of samples of cotton; inspection of bales.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 2 2010-01-01 2010-01-01 false Drawing and handling of samples of cotton; inspection... STANDARDS AND STANDARD CONTAINER REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.20 Drawing and handling of samples of cotton; inspection of bales. One...
7 CFR 27.20 - Drawing and handling of samples of cotton; inspection of bales.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 2 2012-01-01 2012-01-01 false Drawing and handling of samples of cotton; inspection... STANDARDS AND STANDARD CONTAINER REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.20 Drawing and handling of samples of cotton; inspection of bales. One...
7 CFR 27.20 - Drawing and handling of samples of cotton; inspection of bales.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 2 2013-01-01 2013-01-01 false Drawing and handling of samples of cotton; inspection... STANDARDS AND STANDARD CONTAINER REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.20 Drawing and handling of samples of cotton; inspection of bales. One...
7 CFR 27.20 - Drawing and handling of samples of cotton; inspection of bales.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 2 2011-01-01 2011-01-01 false Drawing and handling of samples of cotton; inspection... STANDARDS AND STANDARD CONTAINER REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Inspection and Samples § 27.20 Drawing and handling of samples of cotton; inspection of bales. One...
Techniques for immobilizing and bleeding marmots and woodrats.
Frase, B A; Van Vuren, D
1989-07-01
Blood samples were obtained in the field by femoral vein puncture in bushy-tailed woodrats (Neotoma cinerea) and yellow-bellied marmots (Marmota flaviventris) that had been injected intramuscularly with ketamine hydrochloride. Dosages ranged from 50 mg/kg for marmots to 30 to 110 mg/kg for woodrats. Sedated animals were handled easily, and a volume of blood sufficient for hematological assays or electrophoresis could be collected.
The Sample Handling System for the Mars Icebreaker Life Mission: from Dirt to Data
NASA Technical Reports Server (NTRS)
Dave, Arwen; Thompson, Sarah J.; McKay, Christopher P.; Stoker, Carol R.; Zacny, Kris; Paulsen, Gale; Mellerowicz, Bolek; Glass, Brian J.; Wilson, David; Bonaccorsi, Rosalba;
2013-01-01
The Mars icebreaker life mission will search for subsurface life on mars. It consists of three payload elements: a drill to retrieve soil samples from approx. 1 meter below the surface, a robotic sample handling system to deliver the sample from the drill to the instruments, and the instruments themselves. This paper will discuss the robotic sample handling system.
A quick and effective method of limb preparation with health, safety and efficiency benefits.
Naderi, N; Maw, K; Thomas, M; Boyce, D E; Shokrollahi, K
2012-03-01
Pre-operative limb preparation (PLP) usually involves lifting the limb and holding it in a fixed 'static' posture for several minutes. This is hazardous to theatre staff. Furthermore, 'painting' the limb can be time consuming and difficult areas such as between toes and fingers may remain unsterile. We demonstrate the time efficiency and asepsis achieved using the 'sterile bag' preparation technique. An additional advantage is the ability to prepare and anaesthetise a limb prior to theatre, increasing efficiency substantially for units with a large throughput of cases, such as day-case hand surgery lists. We monitored the duration of PLP in 20 patients using the 'sterile bag' technique compared to 20 patients using a conventional 'painting' method. Additionally, microbiology samples acquired from prepared upper limbs of 27 sequential patients operated on by a single surgeon over a two-month period were sent for culture immediately prior to commencement of surgery. The mean duration of the 'sterile bag' PLP was significantly lower than that of the conventional method (24 seconds vs 85 seconds, p=0.045). The technique can take as little as ten seconds (n=1). Final microbiology reports showed no growth for any of the 27 patients from whom a culture sample was taken. The sterile bag technique is effective in achieving asepsis, has the potential to increase theatre efficiency and reduces manual handling hazards compared to the conventional method. It is now taught to all theatre staff in our hospital during manual handling training. It can be undertaken in approximately ten seconds with practice for the upper limb.
Sensitive microplate assay for the detection of proteolytic enzymes using radiolabeled gelatin
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robertson, B.D.; Kwan-Lim, G.E.; Maizels, R.M.
1988-07-01
A sensitive, microplate assay is described for the detection of a wide range of proteolytic enzymes, using radio-iodine-labeled gelatin as substrate. The technique uses the Bolton-Hunter reagent to label the substrate, which is then coated onto the wells of polyvinyl chloride microtiter plates. By measuring the radioactivity released the assay is able to detect elastase, trypsin, and collagenase in concentrations of 1 ng/ml or less, while the microtiter format permits multiple sample handling and minimizes sample volumes required for analysis.
The effect of handling method on the mouse grimace scale in two strains of laboratory mice
Leach, Matthew C
2015-01-01
Pain assessment in laboratory animals is an ethical and legal requirement. The mouse grimace scale (MGS) is a new method of pain assessment deemed to be both accurate and reliable, and observers can be rapidly trained to use it. In order for a new pain assessment technique to be effective, we must ensure that the score awarded by the technique is only influenced by pain and not by other husbandry or non-painful but integral aspects of research protocols. Here, we studied 16 male mice, housed under standard laboratory conditions. Eight mice were randomly assigned to tail handling and eight to tube handling on arrival at the unit. On each occasion the mice were removed from their cage for routine husbandry, they were picked up using their assigned handling method. Photographs of the mouse faces were then scored by treatment-blind observers as per the MGS manual (see Nature Methods 2010, Vol. 7, pp 447–449), and scores from the two groups were compared. There was no significant difference in MGS scores between the mice that had been handled using a tube compared with the tail. Consequently, these methods of handling did not influence the baseline grimace score given, suggesting that these handling techniques are not confounding factors when establishing baseline MGS scores, further validating this technique. PMID:26657061
The effect of handling method on the mouse grimace scale in two strains of laboratory mice.
Miller, Amy L; Leach, Matthew C
2016-08-01
Pain assessment in laboratory animals is an ethical and legal requirement. The mouse grimace scale (MGS) is a new method of pain assessment deemed to be both accurate and reliable, and observers can be rapidly trained to use it. In order for a new pain assessment technique to be effective, we must ensure that the score awarded by the technique is only influenced by pain and not by other husbandry or non-painful but integral aspects of research protocols. Here, we studied 16 male mice, housed under standard laboratory conditions. Eight mice were randomly assigned to tail handling and eight to tube handling on arrival at the unit. On each occasion the mice were removed from their cage for routine husbandry, they were picked up using their assigned handling method. Photographs of the mouse faces were then scored by treatment-blind observers as per the MGS manual (see Nature Methods 2010, Vol. 7, pp 447-449), and scores from the two groups were compared. There was no significant difference in MGS scores between the mice that had been handled using a tube compared with the tail. Consequently, these methods of handling did not influence the baseline grimace score given, suggesting that these handling techniques are not confounding factors when establishing baseline MGS scores, further validating this technique. © The Author(s) 2015.
The UK Biobank sample handling and storage validation studies.
Peakman, Tim C; Elliott, Paul
2008-04-01
and aims UK Biobank is a large prospective study in the United Kingdom to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. It involves the collection of blood and urine from 500 000 individuals aged between 40 and 69 years. How the samples are collected, processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. A series of validation studies was recommended to test the robustness of the draft sample handling and storage protocol. Samples of blood and urine were collected from 40 healthy volunteers and either processed immediately according to the protocol or maintained at specified temperatures (4 degrees C for all tubes with the exception of vacutainers containing acid citrate dextrose that were maintained at 18 degrees C) for 12, 24 or 36 h prior to processing. A further sample was maintained for 24 h at 4 degrees C, processed and the aliquots frozen at -80 degrees C for 20 days and then thawed under controlled conditions. The stability of the samples was compared for the different times in a wide variety of assays. The samples maintained at 4 degrees C were stable for at least 24 h after collection for a wide range of assays. Small but significant changes were observed in metabonomic studies in samples maintained at 4 degrees C for 36 h. There was no degradation of the samples for a range of biochemical assays after short-term freezing and thawing under controlled conditions. Whole blood maintained at 18 degrees C for 24 h in vacutainers containing acid citrate dextrose is suitable for viral immortalization techniques. The validation studies reported in this supplement provide justification for the sample handling and storage procedures adopted in the UK Biobank project.
Kappagantu, Madhu; Villamor, Dan Edward V; Bullock, Jeff M; Eastwell, Kenneth C
2017-07-01
Hop stunt disease caused by Hop stunt viroid (HSVd) is a growing threat to hop cultivation globally. HSVd spreads mainly by use of contaminated planting material and by mechanical means. Thorough testing of hop yards and removal of infected bines are critical components of efforts to control the spread of the disease. Reverse transcription-polymerase chain reaction (RT-PCR) has become the primary technique used for HSVd detection; however, sample handling and analysis are technically challenging. In this study, a robust reverse transcription-recombinase polymerase amplification (RT-RPA) assay was developed to facilitate analysis of multiple samples. The assay was optimized with all major variants of HSVd from other host species in addition to hop variants. Used in conjunction with sample collection cards, RT-RPA accommodates large sample numbers. Greenhouse and farm samples tested with RT-RPA were also tested with RT-PCR and a 100% correlation between the two techniques was found. Copyright © 2017. Published by Elsevier B.V.
NASA Technical Reports Server (NTRS)
Fletcher, L. A.; Allen, C. C.; Bastien, R.
2008-01-01
NASA's Johnson Space Center (JSC) and the Astromaterials Curator are charged by NPD 7100.10D with the curation of all of NASA s extraterrestrial samples, including those from future missions. This responsibility includes the development of new sample handling and preparation techniques; therefore, the Astromaterials Curator must begin developing procedures to preserve, prepare and ship samples at sub-freezing temperatures in order to enable future sample return missions. Such missions might include the return of future frozen samples from permanently-shadowed lunar craters, the nuclei of comets, the surface of Mars, etc. We are demonstrating the ability to curate samples under cold conditions by designing, installing and testing a cold curation glovebox. This glovebox will allow us to store, document, manipulate and subdivide frozen samples while quantifying and minimizing contamination throughout the curation process.
NASA Technical Reports Server (NTRS)
Linford, R. M. F.; Allen, T. H.; Dillow, C. F.
1975-01-01
A program is described to design, fabricate and install an experimental work chamber assembly (WCA) to provide a wide range of experimental capability. The WCA incorporates several techniques for studying the kinetics of contaminant films and their effect on optical surfaces. It incorporates the capability for depositing both optical and contaminant films on temperature-controlled samples, and for in-situ measurements of the vacuum ultraviolet reflectance. Ellipsometer optics are mounted on the chamber for film thickness determinations, and other features include access ports for radiation sources and instrumentation. Several supporting studies were conducted to define specific chamber requirements, to determine the sensitivity of the measurement techniques to be incorporated in the chamber, and to establish procedures for handling samples prior to their installation in the chamber. A bibliography and literature survey of contamination-related articles is included.
Fifty years of solid-phase extraction in water analysis--historical development and overview.
Liska, I
2000-07-14
The use of an appropriate sample handling technique is a must in an analysis of organic micropollutants in water. The efforts to use a solid phase for the recovery of analytes from a water matrix prior to their detection have a long history. Since the first experimental trials using activated carbon filters that were performed 50 years ago, solid-phase extraction (SPE) has become an established sample preparation technique. The initial experimental applications of SPE resulted in widespread use of this technique in current water analysis and also to adoption of SPE into standardized analytical methods. During the decades of its evolution, chromatographers became aware of the advantages of SPE and, despite many innovations that appeared in the last decade, new SPE developments are still expected in the future. A brief overview of 50 years of the history of the use of SPE in organic trace analysis of water is given in presented paper.
NASA Technical Reports Server (NTRS)
Kriegler, F. J.
1973-01-01
The improvement and extension of the capabilities of the Environmental Research Institute of Michigan processing facility in handling multispectral data are discussed. Improvements consisted of implementing hardware modifications which permitted more rapid access to the recorded data through improved numbering and indexing of such data. In addition, techniques are discussed for handling data from sources other than the ERIM M-5 and M-7 scanner systems.
Mass spectrometry-based proteomics for translational research: a technical overview.
Paulo, Joao A; Kadiyala, Vivek; Banks, Peter A; Steen, Hanno; Conwell, Darwin L
2012-03-01
Mass spectrometry-based investigation of clinical samples enables the high-throughput identification of protein biomarkers. We provide an overview of mass spectrometry-based proteomic techniques that are applicable to the investigation of clinical samples. We address sample collection, protein extraction and fractionation, mass spectrometry modalities, and quantitative proteomics. Finally, we examine the limitations and further potential of such technologies. Liquid chromatography fractionation coupled with tandem mass spectrometry is well suited to handle mixtures of hundreds or thousands of proteins. Mass spectrometry-based proteome elucidation can reveal potential biomarkers and aid in the development of hypotheses for downstream investigation of the molecular mechanisms of disease.
Lunar carbon chemistry - Relations to and implications for terrestrial organic geochemistry.
NASA Technical Reports Server (NTRS)
Eglinton, G.; Maxwell, J. R.; Pillinger, C. T.
1972-01-01
Survey of the various ways in which studies of lunar carbon chemistry have beneficially affected terrestrial organic geochemistry. A lunar organic gas-analysis operating system is cited as the most important instrumental development in relation to terrestrial organic geochemistry. Improved methods of analysis and handling of organic samples are cited as another benefit derived from studies of lunar carbon chemistry. The problem of controlling contamination and minimizing organic vapors is considered, as well as the possibility of analyzing terrestrial samples by the techniques developed for lunar samples. A need for new methods of analyzing carbonaceous material which is insoluble in organic solvents is indicated.
Mass Spectrometry-Based Proteomics for Translational Research: A Technical Overview
Paulo, Joao A.; Kadiyala, Vivek; Banks, Peter A.; Steen, Hanno; Conwell, Darwin L.
2012-01-01
Mass spectrometry-based investigation of clinical samples enables the high-throughput identification of protein biomarkers. We provide an overview of mass spectrometry-based proteomic techniques that are applicable to the investigation of clinical samples. We address sample collection, protein extraction and fractionation, mass spectrometry modalities, and quantitative proteomics. Finally, we examine the limitations and further potential of such technologies. Liquid chromatography fractionation coupled with tandem mass spectrometry is well suited to handle mixtures of hundreds or thousands of proteins. Mass spectrometry-based proteome elucidation can reveal potential biomarkers and aid in the development of hypotheses for downstream investigation of the molecular mechanisms of disease. PMID:22461744
A pilot modeling technique for handling-qualities research
NASA Technical Reports Server (NTRS)
Hess, R. A.
1980-01-01
A brief survey of the more dominant analysis techniques used in closed-loop handling-qualities research is presented. These techniques are shown to rely on so-called classical and modern analytical models of the human pilot which have their foundation in the analysis and design principles of feedback control. The optimal control model of the human pilot is discussed in some detail and a novel approach to the a priori selection of pertinent model parameters is discussed. Frequency domain and tracking performance data from 10 pilot-in-the-loop simulation experiments involving 3 different tasks are used to demonstrate the parameter selection technique. Finally, the utility of this modeling approach in handling-qualities research is discussed.
Options in Extraterrestrial Sample Handling and Study
NASA Technical Reports Server (NTRS)
Papanastassiou, Dimitri A.
2000-01-01
This presentation mentions important service functions such as: sample preservation, hazard assessment, and handling. It also discuss how preliminary examination of samples is necessary for sample hazard assessment and for sample allocations. Clean facilities and clean sample handling are required. Conflicts, cross contamination issues will be present and need to be resolved. Extensive experience is available for extraterrestrial samples and must be sought and applied. Extensive experience is available in studies of pathogenicity and must be sought and applied as necessary. Advisory and oversight structures must also be in place
ERIC Educational Resources Information Center
Erdmann, Mitzy A.; March, Joe L.
2016-01-01
Sample handling and laboratory notebook maintenance are necessary skills but can seem abstract if not presented to students in context. An introductory exercise focusing on proper sample handling, data collection and laboratory notebook keeping for the general chemistry laboratory was developed to emphasize the importance of keeping an accurate…
A radiographic scanning technique for cores
Hill, G.W.; Dorsey, M.E.; Woods, J.C.; Miller, R.J.
1979-01-01
A radiographic scanning technique (RST) can produce single continuous radiographs of cores or core sections up to 1.5 m long and up to 30 cm wide. Changing a portable industrial X-ray unit from the normal still-shot mode to a scanning mode requires simple, inexpensive, easily constructed, and highly durable equipment. Additional components include a conveyor system, antiscatter cylinder-diaphragm, adjustable sample platform, developing tanks, and a contact printer. Complete cores, half cores, sample slabs or peels may be scanned. Converting the X-ray unit from one mode to another is easy and can be accomplished without the use of special tools. RST provides the investigator with a convenient, continuous, high quality radiograph, saves time and money, and decreases the number of times cores have to be handled. ?? 1979.
Aircraft model prototypes which have specified handling-quality time histories
NASA Technical Reports Server (NTRS)
Johnson, S. H.
1976-01-01
Several techniques for obtaining linear constant-coefficient airplane models from specified handling-quality time histories are discussed. One technique, the pseudodata method, solves the basic problem, yields specified eigenvalues, and accommodates state-variable transfer-function zero suppression. The method is fully illustrated for a fourth-order stability-axis small-motion model with three lateral handling-quality time histories specified. The FORTRAN program which obtains and verifies the model is included and fully documented.
Isaksson, Mats; Hagström, Åsa; Armua-Fernandez, Maria Teresa; Wahlström, Helene; Ågren, Erik Olof; Miller, Andrea; Holmberg, Anders; Lukacs, Morten; Casulli, Adriano; Deplazes, Peter; Juremalm, Mikael
2014-12-19
Following the first finding of Echinococcus multilocularis in Sweden in 2011, 2985 red foxes (Vulpes vulpes) were analysed by the segmental sedimentation and counting technique. This is a labour intensive method and requires handling of the whole carcass of the fox, resulting in a costly analysis. In an effort to reduce the cost of labour and sample handling, an alternative method has been developed. The method is sensitive and partially automated for detection of E. multilocularis in faecal samples. The method has been used in the Swedish E. multilocularis monitoring program for 2012-2013 on more than 2000 faecal samples. We describe a new semi-automated magnetic capture probe DNA extraction method and real time hydrolysis probe polymerase chain reaction assay (MC-PCR) for the detection of E. multilocularis DNA in faecal samples from red fox. The diagnostic sensitivity was determined by validating the new method against the sedimentation and counting technique in fox samples collected in Switzerland where E. multilocularis is highly endemic. Of 177 foxes analysed by the sedimentation and counting technique, E. multilocularis was detected in 93 animals. Eighty-two (88%, 95% C.I 79.8-93.9) of these were positive in the MC-PCR. In foxes with more than 100 worms, the MC-PCR was positive in 44 out of 46 (95.7%) cases. The two MC-PCR negative samples originated from foxes with only immature E. multilocularis worms. In foxes with 100 worms or less, (n = 47), 38 (80.9%) were positive in the MC-PCR. The diagnostic specificity of the MC-PCR was evaluated using fox scats collected within the Swedish screening. Of 2158 samples analysed, two were positive. This implies that the specificity is at least 99.9% (C.I. = 99.7-100). The MC-PCR proved to have a high sensitivity and a very high specificity. The test is partially automated but also possible to perform manually if desired. The test is well suited for nationwide E. multilocularis surveillance programs where sampling of fox scats is done to reduce the costs for sampling and where a test with a high sensitivity and a very high specificity is needed.
SOIL AND SEDIMENT SAMPLING METHODS | Science ...
The EPA Office of Solid Waste and Emergency Response's (OSWER) Office of Superfund Remediation and Technology Innovation (OSRTI) needs innovative methods and techniques to solve new and difficult sampling and analytical problems found at the numerous Superfund sites throughout the United States. Inadequate site characterization and a lack of knowledge of surface and subsurface contaminant distributions hinders EPA's ability to make the best decisions on remediation options and to conduct the most effective cleanup efforts. To assist OSWER, NERL conducts research to improve their capability to more accurately, precisely, and efficiently characterize Superfund, RCRA, LUST, oil spills, and brownfield sites and to improve their risk-based decision making capabilities, research is being conducted on improving soil and sediment sampling techniques and improving the sampling and handling of volatile organic compound (VOC) contaminated soils, among the many research programs and tasks being performed at ESD-LV.Under this task, improved sampling approaches and devices will be developed for characterizing the concentration of VOCs in soils. Current approaches and devices used today can lose up to 99% of the VOCs present in the sample due inherent weaknesses in the device and improper/inadequate collection techniques. This error generally causes decision makers to markedly underestimate the soil VOC concentrations and, therefore, to greatly underestimate the ecological
The History of Presolar Grains
NASA Technical Reports Server (NTRS)
Bernatowicz, Thomas J.
2004-01-01
Below we summarize the results of our investigations into the history of presolar grains that were conducted in the last year. During this time we have expended much of our effort in the development of experimental techniques and sample preparation methods that are needed to laboratory in December, 2000. Specific information on this instrument is contained in the Full Proposal of PI Ernst Zinner and will not be repeated here. Our general strategy in the past year has been in large measure to explore novel sample handling methods for the very small (sub-micron), but more representative, presolar grains that can now be characterized isotopically in the NanoSIMS. We have developed experimental techniques that will permit NanoSIMS analyses of the very same ultramicrotome sections studied in the TEM, and we have developed grain dispersion, handling and mounting techniques that permit NanoSIMS isotopic analysis as well as field emission SEM, high energy TEM, and atomic force microscopy of pristine presolar grains. Although much of this has been slow and very difficult work that has no immediate payoff in terms of publishable results, we considered it absolutely necessary groundwork for future discoveries, especially in the realm of individual presolar grains that have been inaccessible to past studies due to size constraints. As discussed below, we have been largely successful in these endeavors, and expect to reap the benefits of this work in the next year. We also report on our continued morphologic studies of pristine presolar grains, on our investigations of presolar graphite grains from supernovae as well as on rarer types of presotar SIC, on the search for presolar silicates, and on our efforts to obtain direct size-distribution information on presolar SiC through X-ray mapping techniques.
Schminkey, Donna L; von Oertzen, Timo; Bullock, Linda
2016-08-01
With increasing access to population-based data and electronic health records for secondary analysis, missing data are common. In the social and behavioral sciences, missing data frequently are handled with multiple imputation methods or full information maximum likelihood (FIML) techniques, but healthcare researchers have not embraced these methodologies to the same extent and more often use either traditional imputation techniques or complete case analysis, which can compromise power and introduce unintended bias. This article is a review of options for handling missing data, concluding with a case study demonstrating the utility of multilevel structural equation modeling using full information maximum likelihood (MSEM with FIML) to handle large amounts of missing data. MSEM with FIML is a parsimonious and hypothesis-driven strategy to cope with large amounts of missing data without compromising power or introducing bias. This technique is relevant for nurse researchers faced with ever-increasing amounts of electronic data and decreasing research budgets. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Double-pointed 30-gauge needle for keratocentesis.
Angi, M R; Endara, N I
1985-12-01
A new, efficient instrument for performing keratocentesis for aqueous humour aspiration and anterior chamber microinfusion is described. It consists of a double-pointed 30-gauge needle, a liquid container (a nonflexible vinyl tube plugged at one end with a rubber stopper) and a aspiration-infusion syringe connected to the container and needle by a flexible vinyl tube. The instrument's advantages are a safer technique, complete collection of the aqueous humour and better handling of the sample.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vogel, Sven C.; Losko, Adrian Simon; Pokharel, Reeju
The goal of the Advanced Non-destructive Fuel Examination (ANDE) work package is the development and application of non-destructive neutron imaging and scattering techniques to ceramic and metallic nuclear fuels, ultimately also to irradiated fuels. The results of these characterizations provide complete pre- and post-irradiation on length scales ranging from mm to nm, guide destructive examination, and inform modelling efforts. Besides technique development and application to samples to be irradiated, the ANDE work package also examines possible technologies to provide these characterization techniques pool-side, e.g. at the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) using laser-driven intense pulsed neutronmore » and gamma sources. Neutron tomography and neutron diffraction characterizations were performed on nine pellets; four UN/ U-Si composite formulations (two enrichment levels), three pure U 3Si 5 reference formulations (two enrichment levels), and two reject pellets with visible flaws (to qualify the technique). The 235U enrichments ranged from 0.2 to 8.8 wt. %. The nitride/silicide composites are candidate compositions for use as Accident Tolerant Fuel (ATF). The monophase U 3Si 5 material was included as a reference. Pellets from the same fabrication batches will be inserted in the Advanced Test Reactor at Idaho during 2016. We have also proposed a data format to build a database for characterization results of individual pellets. Neutron data reported in this report were collected in the LANSCE run cycle that started in September 2015 and ended in March 2016. This report provides the results for the characterized samples and discussion in the context of ANDE and APIE. We quantified the gamma spectra of several samples in their received state as well as after neutron irradiation to ensure that the neutron irradiation does not add significant activation that would complicate shipment and handling. We demonstrated synchrotron-based 3D X-ray microscopy on the composite fuel materials, providing unparalleled level of detail on the 3D microstructure. Furthermore, we initiated development of shielding containers allowing the characterizations presented herein while allowing handling of irradiated samples.« less
NASA Technical Reports Server (NTRS)
Lakshminarayana, B.
1991-01-01
Various computational fluid dynamic techniques are reviewed focusing on the Euler and Navier-Stokes solvers with a brief assessment of boundary layer solutions, and quasi-3D and quasi-viscous techniques. Particular attention is given to a pressure-based method, explicit and implicit time marching techniques, a pseudocompressibility technique for incompressible flow, and zonal techniques. Recommendations are presented with regard to the most appropriate technique for various flow regimes and types of turbomachinery, incompressible and compressible flows, cascades, rotors, stators, liquid-handling, and gas-handling turbomachinery.
NASA Technical Reports Server (NTRS)
White, D. R.
1976-01-01
A high-vacuum complex composed of an atmospheric decontamination system, sample-processing chambers, storage chambers, and a transfer system was built to process and examine lunar material while maintaining quarantine status. Problems identified, equipment modifications, and procedure changes made for Apollo 11 and 12 sample processing are presented. The sample processing experiences indicate that only a few operating personnel are required to process the sample efficiently, safely, and rapidly in the high-vacuum complex. The high-vacuum complex was designed to handle the many contingencies, both quarantine and scientific, associated with handling an unknown entity such as the lunar sample. Lunar sample handling necessitated a complex system that could not respond rapidly to changing scientific requirements as the characteristics of the lunar sample were better defined. Although the complex successfully handled the processing of Apollo 11 and 12 lunar samples, the scientific requirement for vacuum samples was deleted after the Apollo 12 mission just as the vacuum system was reaching its full potential.
Coring Sample Acquisition Tool
NASA Technical Reports Server (NTRS)
Haddad, Nicolas E.; Murray, Saben D.; Walkemeyer, Phillip E.; Badescu, Mircea; Sherrit, Stewart; Bao, Xiaoqi; Kriechbaum, Kristopher L.; Richardson, Megan; Klein, Kerry J.
2012-01-01
A sample acquisition tool (SAT) has been developed that can be used autonomously to sample drill and capture rock cores. The tool is designed to accommodate core transfer using a sample tube to the IMSAH (integrated Mars sample acquisition and handling) SHEC (sample handling, encapsulation, and containerization) without ever touching the pristine core sample in the transfer process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bolivar, S.
This manual describes field procedures for the collection of stream-sediment and rock samples as part of the Mineral Resource Assessment of Costa Rica. It provides guidelines to be followed by personnel collecting, treating, or otherwise handling samples taken as part of this program. The objectives of the manual are to ensure that all samples are collected uniformly and consistent techniques are employed throughout the program. If this is done, the data from this study can be used to identify areas with potential for mineralization. This manual can also be used as a guideline for future geochemical sampling programs in Costamore » Rica.« less
Causes of toxicity in stormwater runoff from sawmills
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bailey, H.C.; Elphick, J.R.; Potter, A.
1999-07-01
Samples of stormwater runoff from nine sawmills in British Columbia, Canada, were tested for acute toxicity with juvenile rainbow trout over a 23-month period. Forty-two of the 58 samples tested exhibited toxicity. Causes of toxicity were investigated using toxicity identification evaluation techniques. Toxicity was attributed to divalent cations, particularly zinc, in 32 of the samples. The low hardness associated with most of the samples increased the potential for metal toxicity. For example, the LC50 of zinc was 14 {micro}g/L at a hardness of 5 mg/L. Toxicity in the remaining samples was largely attributed to tannins and lignins and was associatedmore » with areas of bulk log handling. No evidence was found to indicate that antisapstain chemicals applied to freshly cut wood contributed to toxicity.« less
NASA Technical Reports Server (NTRS)
Powers, B. G.
1972-01-01
The magnitude and frequency of occurrence of aircraft responses and control inputs during 27 flights of the XB-70 airplane were measured. Exceedance curves are presented for the airplane responses and control usage. A technique is presented which makes use of these exceedance curves to establish or verify handling qualities criteria. This technique can provide a means of incorporating current operational experience in handling qualities requirements for future aircraft.
Planetary sample rapid recovery and handling
NASA Technical Reports Server (NTRS)
1985-01-01
Methods for recovering and cost effectively handling planetary samples following return to the vicinity of Earth were designed for planetary mission planners. Three topics are addressed: (1) a rough cost estimate was produced for each of a series of options for the handling of planetary samples following their return to the vicinity of Earth; (2) the difficulty of quickly retrieving planetary samples from low circular and high elliptical Earth orbit is assessed; and (3) a conceptual design for a biological isolation and thermal control system for the returned sample and spacecraft is developed.
Robotic sampling system for an unmanned Mars mission
NASA Technical Reports Server (NTRS)
Chun, Wendell
1989-01-01
A major robotics opportunity for NASA will be the Mars Rover/Sample Return Mission which could be launched as early as the 1990s. The exploratory portion of this mission will include two autonomous subsystems: the rover vehicle and a sample handling system. The sample handling system is the key to the process of collecting Martian soils. This system could include a core drill, a general-purpose manipulator, tools, containers, a return canister, certification hardware and a labeling system. Integrated into a functional package, the sample handling system is analogous to a complex robotic workcell. Discussed here are the different components of the system, their interfaces, forseeable problem areas and many options based on the scientific goals of the mission. The various interfaces in the sample handling process (component to component and handling system to rover) will be a major engineering effort. Two critical evaluation criteria that will be imposed on the system are flexibility and reliability. It needs to be flexible enough to adapt to different scenarios and environments and acquire the most desirable specimens for return to Earth. Scientists may decide to change the distribution and ratio of core samples to rock samples in the canister. The long distance and duration of this planetary mission places a reliability burden on the hardware. The communication time delay between Earth and Mars minimizes operator interaction (teleoperation, supervisory modes) with the sample handler. An intelligent system will be required to plan the actions, make sample choices, interpret sensor inputs, and query unknown surroundings. A combination of autonomous functions and supervised movements will be integrated into the sample handling system.
Mars Sample Handling Functionality
NASA Astrophysics Data System (ADS)
Meyer, M. A.; Mattingly, R. L.
2018-04-01
The final leg of a Mars Sample Return campaign would be an entity that we have referred to as Mars Returned Sample Handling (MRSH.) This talk will address our current view of the functional requirements on MRSH, focused on the Sample Receiving Facility (SRF).
Study of the production of unique new glasses
NASA Technical Reports Server (NTRS)
Happe, R. A.
1972-01-01
A number of high new oxide glasses have been prepared by a laser-spin melting technique where droplets are ejected from a molten mass. Techniques have been developed for measuring the optical properties of most of the new glasses so produced. A preliminary study of processing equipment for producing new glasses in a zero gravity environment onboard manned space laboratory is reported. Induction and laser melting emerge as preferred techniques for melting spheroids of new glass compositions in space. Sample calculations for power required to induction melt new glass compositions are presented. Cooling rate calculations show that radiation cooling of the high melting materials results in very short cooling times for 1/2 inch diameters to temperatures where the spheroids can be handled.
Wipe-rinse technique for quantitating microbial contamination on large surfaces.
Kirschner, L E; Puleo, J R
1979-01-01
The evaluation of an improved wipe-rinse technique for the bioassay of large areas was undertaken due to inherent inadequacies in the cotton swab-rinse technique to which assay of spacecraft is currently restricted. Four types of contamination control cloths were initially tested. A polyester-bonded cloth (PBC) was selected for further evaluation because of its superior efficiency and handling characteristics. Results from comparative tests with PBC and cotton swabs on simulated spacecraft surfaces indicated a significantly higher recovery efficiency for the PBC than for the cotton (90.4 versus 75.2%). Of the sampling areas sites studied, PBC was found to be most effective on surface areas not exceeding 0.74 m2 (8.0 feet 2). PMID:394682
Wipe-rinse technique for quantitating microbial contamination on large surfaces
NASA Technical Reports Server (NTRS)
Kirschner, L. E.; Puleo, J. R.
1979-01-01
The evaluation of an improved wipe-rinse technique for the bioassay of large areas was undertaken due to inherent inadequacies in the cotton swab-rinse technique to which assay of spacecraft is currently restricted. Four types of contamination control cloths were initially tested. A polyester-bonded cloth (PBC) was selected for further evaluation because of its superior efficiency and handling characteristics. Results from comparative tests with PBC and cotton swabs on simulated spacecraft surfaces indicated a significantly higher recovery efficiency for the PBC than for the cotton (90.4 versus 75.2%). Of the sampling area sites studied, PBC was found to be most effective on surface areas not exceeding 0.74 sq m (8.0 sq ft).
Zhao, Xiaoyan; Qureshi, Ferhan; Eastman, P Scott; Manning, William C; Alexander, Claire; Robinson, William H; Hesterberg, Lyndal K
2012-04-30
Variability in pre-analytical blood sampling and handling can significantly impact results obtained in quantitative immunoassays. Understanding the impact of these variables is critical for accurate quantification and validation of biomarker measurements. Particularly, in the design and execution of large clinical trials, even small differences in sample processing and handling can have dramatic effects in analytical reliability, results interpretation, trial management and outcome. The effects of two common blood sampling methods (serum vs. plasma) and two widely-used serum handling methods (on the clot with ambient temperature shipping, "traditional", vs. centrifuged with cold chain shipping, "protocol") on protein and autoantibody concentrations were examined. Matched serum and plasma samples were collected from 32 rheumatoid arthritis (RA) patients representing a wide range of disease activity status. Additionally, a set of matched serum samples with two sample handling methods was collected. One tube was processed per manufacturer's instructions and shipped overnight on cold packs (protocol). The matched tube, without prior centrifugation, was simultaneously shipped overnight at ambient temperatures (traditional). Upon delivery, the traditional tube was centrifuged. All samples were subsequently aliquoted and frozen prior to analysis of protein and autoantibody biomarkers. Median correlation between paired serum and plasma across all autoantibody assays was 0.99 (0.98-1.00) with a median % difference of -3.3 (-7.5 to 6.0). In contrast, observed protein biomarker concentrations were significantly affected by sample types, with median correlation of 0.99 (0.33-1.00) and a median % difference of -10 (-55 to 23). When the two serum collection/handling methods were compared, the median correlation between paired samples for autoantibodies was 0.99 (0.91-1.00) with a median difference of 4%. In contrast, significant increases were observed in protein biomarker concentrations among certain biomarkers in samples processed with the 'traditional' method. Autoantibody quantification appears robust to both sample type (plasma vs. serum) and pre-analytical sample collection/handling methods (protocol vs. traditional). In contrast, for non-antibody protein biomarker concentrations, sample type had a significant impact; plasma samples generally exhibit decreased protein biomarker concentrations relative to serum. Similarly, sample handling significantly impacted the variability of protein biomarker concentrations. When biomarker concentrations are combined algorithmically into a single test score such as a multi-biomarker disease activity test for rheumatoid arthritis (MBDA), changes in protein biomarker concentrations may result in a bias of the score. These results illustrate the importance of characterizing pre-analytical methodology, sample type, sample processing and handling procedures for clinical testing in order to ensure test accuracy. Copyright © 2012 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Cicirello, Nancy; And Others
This manual helps physical and occupational therapists instruct nontherapists in positioning and handling students with physical disabilities. A chapter on movement and motor disability covers types of abnormality in muscle tone. A chapter on handling explains appropriate handling techniques and why they are necessary to the student's well-being.…
Cozzolino, Daniel
2015-03-30
Vibrational spectroscopy encompasses a number of techniques and methods including ultra-violet, visible, Fourier transform infrared or mid infrared, near infrared and Raman spectroscopy. The use and application of spectroscopy generates spectra containing hundreds of variables (absorbances at each wavenumbers or wavelengths), resulting in the production of large data sets representing the chemical and biochemical wine fingerprint. Multivariate data analysis techniques are then required to handle the large amount of data generated in order to interpret the spectra in a meaningful way in order to develop a specific application. This paper focuses on the developments of sample presentation and main sources of error when vibrational spectroscopy methods are applied in wine analysis. Recent and novel applications will be discussed as examples of these developments. © 2014 Society of Chemical Industry.
CTEPP STANDARD OPERATING PROCEDURE FOR HANDLING MISSING SAMPLES AND DATA (SOP-2.24)
This SOP describes the method for handling missing samples or data. Missing samples or data will be identified as soon as possible during field sampling. It provides guidance to collect the missing sample or data and document the reason for the missing sample or data.
Determination of methyl bromide in air samples by headspace gas chromatography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woodrow, J.E.; McChesney, M.M.; Seiber, J.N.
1988-03-01
Methyl bromide is extensively used in agriculture (4 x 10/sup 6/ kg for 1985 in California alone as a fumigant to control nematodes, weeds, and fungi in soil and insect pests in harvested grains and nuts. Given its low boiling point (3.8/sup 0/C) and high vapor pressure (approx. 1400 Torr at 20/sup 0/C), methyl bromide will readily diffuse if not rigorously contained. Methods for determining methyl bromide and other halocarbons in air vary widely. A common practice is to trap the material from air on an adsorbent, such as polymeric resins, followed by thermal desorption either directly into the analyticalmore » instrumentation or after intermediary cryofocusing. While in some cases analytical detection limits were reasonable (parts per million range), many of the published methods were labor intensive and required special handling techniques that precluded high sample throughput. They describe here a method for the sampling and analysis of airborne methyl bromide that was designed to handle large numbers of samples through automating some critical steps of the analysis. The result was a method that allowed around-the-clock operation with a minimum of operator attention. Furthermore, the method was not specific to methyl bromide and could be used to determine other halocarbons in air.« less
ERIC Educational Resources Information Center
Sheehy, Kieron
2002-01-01
A comparison is made between a new technique (the Handle Technique), Integrated Picture Cueing, and a Word Alone Method. Results show using a new combination of teaching strategies enabled logographic symbols to be used effectively in teaching word recognition to 12 children with severe learning difficulties. (Contains references.) (Author/CR)
Description of Student’s Metacognitive Ability in Understanding and Solving Mathematics Problem
NASA Astrophysics Data System (ADS)
Ahmad, Herlina; Febryanti, Fatimah; Febryanti, Fatimah; Muthmainnah
2018-01-01
This research was conducted qualitative which was aim to describe metacognitive ability to understand and solve the problems of mathematics. The subject of the research was the first year students at computer and networking department of SMK Mega Link Majene. The sample was taken by purposive sampling technique. The data obtained used the research instrument based on the form of students achievements were collected by using test of student’s achievement and interview guidance. The technique of collecting data researcher had observation to ascertain the model that used by teacher was teaching model of developing metacognitive. The technique of data analysis in this research was reduction data, presentation and conclusion. Based on the whole findings in this study it was shown that student’s metacognitive ability generally not develops optimally. It was because of limited scope of the materials, and cognitive teaching strategy handled by verbal presentation and trained continuously in facing cognitive tasks, such as understanding and solving problem.
Sampling device with a capped body and detachable handle
Jezek, Gerd-Rainer
2000-01-01
The apparatus is a sampling device having a pad for sample collection, a body which supports the pad, a detachable handle connected to the body and a cap which encloses and retains the pad and body to protect the integrity of the sample.
Handling of Polyvinylsiloxane Versus Polyether for Implant Impressions.
Farhan, Daniel; Lauer, Wiebke; Heydecke, Guido; Aarabi, Ghazal; Reissmann, Daniel R
2016-01-01
This study compared polyvinylsiloxane with polyether in handling dental impressions. Each participant (N = 39) made four impressions, each a combination of pickup and reseating techniques with polyether or polyvinylsiloxane, of one implant cast representing a specific clinical situation (tooth gaps, limited residual dentition, or edentulous jaw). Handling of impressions was subsequently rated by using a 12-item questionnaire with 100-mm visual analog scales. While mean satisfaction scores were higher for polyvinylsiloxane than for polyether (69.5/63.0, P < .001), differences among subgroups were statistically significant only for pickup technique, limited residual dentition, and edentulous jaw. Implant impressions made with polyvinylsiloxane using a pickup technique seem to be the best option for most clinical situations.
ERIC Educational Resources Information Center
Inge, Katherine J.; Snell, Martha E.
1985-01-01
Two teachers were taught positioning and handling techniques using written task analyses, demonstrations by an occupational therapist, verbal and modeling prompts, corrective feedback, and praise. Training took place in the natural school environment, during school hours, and with students that the teachers taught. A functional relationship…
Milutinović, Dragana; Andrijević, Ilija; Ličina, Milijana; Andrijević, Ljiljana
2015-01-01
This study aimed to assess confidence level of healthcare professionals in venipuncture and their knowledge on the possible causes of in vitro hemolysis. A sample of 94 healthcare professionals (nurses and laboratory technicians) participated in this survey study. A four-section questionnaire was used as a research instrument comprising general information for research participants, knowledge on possible causes of in vitro hemolysis due to type of material used and venipuncture technique and specimen handling, as well as assessment of healthcare professionals' confidence level in their own ability to perform first and last venipuncture. The average score on the knowledge test was higher in nurses' than in laboratory technicians (8.11±1.7, and 7.4±1.5, respectively). The difference in average scores was statistically significant (P=0.035) and Cohen's d in the range of 0.4 indicates that there is a moderate difference on the knowledge test among the health care workers. Only 11/94 of healthcare professionals recognized that blood sample collection from cannula and evacuated tube is method which contributes most to the occurrence of in vitro hemolysis, whereas most risk factors affecting occurrence of in vitro hemolysis during venipuncture were recognized. There were no significant differences in mean score on the knowledge test in relation to the confidence level in venipuncture (P=0.551). Confidence level at last venipuncture among both profiles of healthcare staff was very high, but they showed insufficient knowledge about possible factors affecting hemolysis due to materials used in venipuncture compared with factors due to venipuncture technique and handling of blood sample.
Fluid handling equipment: A compilation
NASA Technical Reports Server (NTRS)
1976-01-01
Devices and techniques used in fluid-handling and vacuum systems are described. Section 1 presents several articles on fluid lines and tubing. Section 2 describes a number of components such as valves, filters, and regulators. The last section contains descriptions of a number of innovative fluid-handling systems.
Sample flow switching techniques on microfluidic chips.
Pan, Yu-Jen; Lin, Jin-Jie; Luo, Win-Jet; Yang, Ruey-Jen
2006-02-15
This paper presents an experimental investigation into electrokinetically focused flow injection for bio-analytical applications. A novel microfluidic device for microfluidic sample handling is presented. The microfluidic chip is fabricated on glass substrates using conventional photolithographic and chemical etching processes and is bonded using a high-temperature fusion method. The proposed valve-less device is capable not only of directing a single sample flow to a specified output port, but also of driving multiple samples to separate outlet channels or even to a single outlet to facilitate sample mixing. The experimental results confirm that the sample flow can be electrokinetically pre-focused into a narrow stream and guided to the desired outlet port by means of a simple control voltage model. The microchip presented within this paper has considerable potential for use in a variety of applications, including high-throughput chemical analysis, cell fusion, fraction collection, sample mixing, and many other applications within the micro-total-analysis systems field.
Biosecurity measures to reduce influenza infections in military barracks in Ghana.
Agbenohevi, Prince Godfred; Odoom, John Kofi; Bel-Nono, Samuel; Nyarko, Edward Owusu; Alhassan, Mahama; Rodgers, David; Danso, Fenteng; Suu-Ire, Richard D; Bonney, Joseph Humphrey Kofi; Aboagye, James; Kronmann, Karl C; Duplessis, Chris; Oyofo, Buhari Anthony; Ampofo, William Kwabena
2015-01-23
Military barracks in Ghana have backyard poultry populations but the methods used here involve low biosecurity measures and high risk zoonosis such as avian influenza A viruses or Newcastle disease. We assessed biosecurity measures intended to minimize the risk of influenza virus infection among troops and poultry keepers in military barracks. We educated troops and used a questionnaire to collect information on animal populations and handling practices from 168 individuals within 203 households in military barracks. Cloacal and tracheal samples were taken from 892 healthy domestic and domesticated wild birds, 91 sick birds and 6 water samples for analysis using molecular techniques for the detection of influenza A virus. Of the 1090 participants educated and 168 that responded to a questionnaire, 818 (75%) and 129 (76.8%) respectively have heard of pandemic avian influenza and the risks associated with its infection. Even though no evidence of the presence of avian influenza infection was found in the 985 birds sampled, only 19.5% of responders indicated they disinfect their coops regularly and 28% wash their hands after handling their birds. Vaccination of birds and use of personal protective clothing while handling the birds were low putting the people at risk. Though some efforts have been made to improve biosecurity practices, interventions that help to protect the poultry flock from direct contact have to be practiced. Basic hygiene like washing of hands with soap and running water and regular cleaning of chicken coops are needed to prevent the spread of diseases among birds and between birds and humans.
Fluorescence Spectroscopy for the Monitoring of Food Processes.
Ahmad, Muhammad Haseeb; Sahar, Amna; Hitzmann, Bernd
Different analytical techniques have been used to examine the complexity of food samples. Among them, fluorescence spectroscopy cannot be ignored in developing rapid and non-invasive analytical methodologies. It is one of the most sensitive spectroscopic approaches employed in identification, classification, authentication, quantification, and optimization of different parameters during food handling, processing, and storage and uses different chemometric tools. Chemometrics helps to retrieve useful information from spectral data utilized in the characterization of food samples. This contribution discusses in detail the potential of fluorescence spectroscopy of different foods, such as dairy, meat, fish, eggs, edible oil, cereals, fruit, vegetables, etc., for qualitative and quantitative analysis with different chemometric approaches.
Hassan, Afifa Afifi
1982-01-01
The gas evolution and the strontium carbonate precipitation techniques to extract dissolved inorganic carbon (DIC) for stable carbon isotope analysis were investigated. Theoretical considerations, involving thermodynamic calculations and computer simulation pointed out several possible sources of error in delta carbon-13 measurements of the DIC and demonstrated the need for experimental evaluation of the magnitude of the error. An alternative analytical technique, equilibration with out-gassed vapor phase, is proposed. The experimental studies revealed that delta carbon-13 of the DIC extracted from a 0.01 molar NaHC03 solution by both techniques agreed within 0.1 per mil with the delta carbon-13 of the DIC extracted by the precipitation technique, and an increase of only 0.27 per mil in that extracted by the gas evolution technique. The efficiency of extraction of DIC decreased with sulfate concentration in the precipitation technique but was independent of sulfate concentration in the gas evolution technique. Both the precipitation and gas evolution technique were found to be satisfactory for extraction of DIC from different kinds of natural water for stable carbon isotope analysis, provided appropriate precautions are observed in handling the samples. For example, it was found that diffusion of atmospheric carbon dioxide does alter the delta carbon-13 of the samples contained in polyethylene bottles; filtration and drying in the air change the delta carbon-13 of the samples contained in polyethylene bottles; filtration and drying in the air change the delta carbon-13 of the precipitation technique; hot manganese dioxide purification changes the delta carbon-13 of carbon dioxide. (USGS)
A Look at Technologies Vis-a-vis Information Handling Techniques.
ERIC Educational Resources Information Center
Swanson, Rowena W.
The paper examines several ideas for information handling implemented with new technologies that suggest directions for future development. These are grouped under the topic headings: Handling Large Data Banks, Providing Personalized Information Packages, Providing Information Specialist Services, and Expanding Man-Machine Interaction. Guides in…
Demircik, Filiz; Klonoff, David; Musholt, Petra B; Ramljak, Sanja; Pfützner, Andreas
2016-10-01
Devices employing electrochemistry-based correction algorithms (EBCAs) are optimized for patient use and require special handling procedures when tested in the laboratory. This study investigated the impact of sample handling on the results of an accuracy and hematocrit interference test performed with BG*Star, iBG*Star; OneTouch Verio Pro and Accu-Chek Aviva versus YSI Stat 2300. Venous heparinized whole blood was manipulated to contain three different blood glucose concentrations (64-74, 147-163, and 313-335 mg/dL) and three different hematocrit levels (30%, 45%, and 60%). Sample preparation was done by either a very EBCA-experienced laboratory testing team (A), a group experienced with other meters but not EBCAs (B), or a team inexperienced with meter testing (C). Team A ensured physiological pO 2 and specific sample handling requirements, whereas teams B and C did not consider pO 2 . Each sample was tested four times with each device. In a separate experiment, a different group similar to group B performed the experiment before (D1) and after (D2) appropriate sample handling training. Mean absolute deviation from YSI was calculated as a metrix for all groups and devices. Mean absolute relative difference was 4.3% with team A (B: 9.2%, C: 5.2%). Team B had much higher readings and team C produced 100% of "sample composition" errors with high hematocrit levels. In a separate experiment, group D showed a result similar to group B before the training and improved significantly when considering the sample handling requirements (D1: 9.4%, D2: 4.5%, P < 0.05). Laboratory performance testing of EBCA devices should only be performed by trained staff considering specific sample handling requirements. The results suggest that healthcare centers should evaluate EBCA-based devices with capillary blood from patients in accordance with the instructions for use to achieve reliable results.
Understanding feline behavior and application for appropriate handling and management.
Rodan, Ilona
2010-11-01
Feline handling in the veterinary hospital is important to protect both people and cats. Restraint has been used to enable us to perform our duties as veterinarians. With increased knowledge of feline behavior and how cats react to fear, newer information provides us with safer handling techniques. With safer and more respectful handling based on understanding the nature of cats and their communication, we can improve feline health care in our hospitals, the human-animal-veterinarian bond, and the welfare of both cats and people. This article explains important aspects of feline communication and how our actions affect cats. By understanding the cat, we can improve our handling techniques to prevent fear and pain for our feline patients, and thus make our veterinary practices more feline friendly and safer for our clients, their cats, and veterinary staff. Copyright © 2010 Elsevier Inc. All rights reserved.
A new passive system for contamination-free long-distance cryo-transfer of biological tissues
NASA Astrophysics Data System (ADS)
Cheng, Tian; Plane, Florent; Søgaard Jensen, Louise Helene; van den Brandt, Ben; Comment, Arnaud; Meibom, Anders
2017-12-01
Several new analytical techniques require long-distance cryogenic transfer of samples that need to be kept at stable temperatures for long time periods, but also to be additionally contamination-free. In this study we developed a passive transfer system to fulfil those requirements. With 125mL of liquid nitrogen stored, one cryo-sectioned sample was maintained around 120±1 K and a pressure of about 3x10-7 mbar for at least 2 hours. With a total transfer weight of 5 Kg this system can be easily handled and carried by any transportation means so that the same sample can be used for different imaging centres located remotely permitting correlative studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalinoski, H.T.; Udseth, H.R.; Wright, B.W.
1986-10-01
The application of on-line supercritical fluid extraction with chemical ionization mass spectrometry and collision induced dissociation tandem mass spectrometry for the rapid identification of parts-per-million levels of several trichothecene mycotoxins is demonstrated. Supercritical carbon dioxide is shown to allow identification of mycotoxins with minimum sample handling in complex natural matrices (e.g., wheat). Tandem mass spectrometry techniques are employed for unambiguous identification of compounds of varying polarity, and false positives from isobaric compounds are avoided. Capillary column supercritical fluid chromatography-mass spectrometry of a supercritical fluid extract of the same sample was also performed and detection limits in the parts-per-billion range appearmore » feasible.« less
Methods and systems for detection of radionuclides
Coates, Jr., John T.; DeVol, Timothy A.
2010-05-25
Disclosed are materials and systems useful in determining the existence of radionuclides in an aqueous sample. The materials provide the dual function of both extraction and scintillation to the systems. The systems can be both portable and simple to use, and as such can beneficially be utilized to determine presence and optionally concentration of radionuclide contamination in an aqueous sample at any desired location and according to a relatively simple process without the necessity of complicated sample handling techniques. The disclosed systems include a one-step process, providing simultaneous extraction and detection capability, and a two-step process, providing a first extraction step that can be carried out in a remote field location, followed by a second detection step that can be carried out in a different location.
Robotics-assisted mass spectrometry assay platform enabled by open-source electronics.
Chiu, Shih-Hao; Urban, Pawel L
2015-02-15
Mass spectrometry (MS) is an important analytical technique with numerous applications in clinical analysis, biochemistry, environmental analysis, geology and physics. Its success builds on the ability of MS to determine molecular weights of analytes, and elucidate their structures. However, sample handling prior to MS requires a lot of attention and labor. In this work we were aiming to automate processing samples for MS so that analyses could be conducted without much supervision of experienced analysts. The goal of this study was to develop a robotics and information technology-oriented platform that could control the whole analysis process including sample delivery, reaction-based assay, data acquisition, and interaction with the analyst. The proposed platform incorporates a robotic arm for handling sample vials delivered to the laboratory, and several auxiliary devices which facilitate and secure the analysis process. They include: multi-relay board, infrared sensors, photo-interrupters, gyroscopes, force sensors, fingerprint scanner, barcode scanner, touch screen panel, and internet interface. The control of all the building blocks is achieved through implementation of open-source electronics (Arduino), and enabled by custom-written programs in C language. The advantages of the proposed system include: low cost, simplicity, small size, as well as facile automation of sample delivery and processing without the intervention of the analyst. It is envisaged that this simple robotic system may be the forerunner of automated laboratories dedicated to mass spectrometric analysis of biological samples. Copyright © 2014 Elsevier B.V. All rights reserved.
A study for hypergolic vapor sensor development
NASA Technical Reports Server (NTRS)
Stetter, J. R.; Tellefsen, K.
1977-01-01
In summary, the following tasks were completed within the scope of this work: (1) a portable Monomethylhydrazine analyzer was developed, designed, fabricated and tested. (2) A portable NO2 analyzer was developed, designed, fabricated and tested. (3) Sampling probes and accessories were designed and fabricated for this instrumentation. (4) Improvements and modifications were made to the model 7630 Ecolyzer in preparation for field testing. (5) Instrument calibration procedures and hydrazine handling techniques necessary to the successful application of this hardware were developed.
2015-10-02
ratio or physical layout than the training sample, or new vs old bananas . For our system, this is similar the multimodal case mentioned above; however...different modes. Foods with multiple “types” such as green, yellow, and brown bananas are seamlessly handled as well. Secondly, with hundreds or thousands...Recognition and Classification of Food Grains, Fruits and Flowers Using Machine Vision. INTERNATIONAL JOURNAL OF FOOD ENGINEERING, 5(4), 2009. [155] T. E
Mineralogy, Petrology, Chronology, and Exposure History of the Chelyabinsk Meteorite and Parent Body
NASA Technical Reports Server (NTRS)
Righter, K.; Abell, P.; Agresti, D.; Berger, E. L.; Burton, A. S.; Delaney, J. S.; Fries, M. D.; Gibson, E. K.; Harrington, R.; Herzog, G. F.;
2015-01-01
The Chelyabinsk meteorite fall on February 15, 2013 attracted much more attention worldwide than do most falls. A consortium led by JSC received 3 masses of Chelyabinsk (Chel-101, -102, -103) that were collected shortly after the fall and handled with care to minimize contamination. Initial studies were reported in 2013; we have studied these samples with a wide range of analytical techniques to better understand the mineralogy, petrology, chronology and exposure history of the Chelyabinsk parent body.
Plasma-Arc Deposited Elemental Boron Film for use as a Durable Nonstick Coating
2007-09-01
therefore inexpensive) to deposit by either magnetron sputtering or vacuum arc techniques. As it turned out, a Ti-coated sample of 1100Al was available...in dual -use applications, such as the ones just mentioned. 2. RESULTS OF THE PHASE I WORK The Phase I project demonstrated that it is possible to...this upgrade, we replaced the original source assembly by one that could handle very long-pulse operation, by including water-cooling in the anode
Rheological characterization of addition polyimide matrix resins and prepregs
NASA Technical Reports Server (NTRS)
Maximovich, M. G.; Galeos, R. M.
1984-01-01
Although graphite-reinforced polyimide matrix composites offer outstanding specific strength and stiffness, together with high thermal oxidative stability, processing problems connected with their rheological behavior remain to be addressed. The present rheological studies on neat polyimide resin systems encountered outgassing during cure. A staging technique has been developed which can successfully handle polyimide samples, and novel methods were applied to generate rheological curves for graphite-reinforced prepregs. The commercial graphite/polyimide systems studied were PRM 15, LARC 160, and V378A.
Recommended Procedures for Handling Emergency Illnesses and Accidents at School.
ERIC Educational Resources Information Center
North Dakota State Dept. of Health, Bismarck.
Recommended procedures for handling emergency illnesses and accidents are provided in this guide for school personnel prepared by the North Dakota State Department of Health. Following five general recommendations for steps to take in emergency situations, advice and techniques are given for handling: nose bleeds; abdominal pain; toothaches and…
Guo, Feng; Zhou, Weijie; Li, Peng; Mao, Zhangming; Yennawar, Neela H; French, Jarrod B; Huang, Tony Jun
2015-06-01
Advances in modern X-ray sources and detector technology have made it possible for crystallographers to collect usable data on crystals of only a few micrometers or less in size. Despite these developments, sample handling techniques have significantly lagged behind and often prevent the full realization of current beamline capabilities. In order to address this shortcoming, a surface acoustic wave-based method for manipulating and patterning crystals is developed. This method, which does not damage the fragile protein crystals, can precisely manipulate and pattern micrometer and submicrometer-sized crystals for data collection and screening. The technique is robust, inexpensive, and easy to implement. This method not only promises to significantly increase efficiency and throughput of both conventional and serial crystallography experiments, but will also make it possible to collect data on samples that were previously intractable. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Marinova, Mariela; Artusi, Carlo; Brugnolo, Laura; Antonelli, Giorgia; Zaninotto, Martina; Plebani, Mario
2013-11-01
Although, due to its high specificity and sensitivity, LC-MS/MS is an efficient technique for the routine determination of immunosuppressants in whole blood, it involves time-consuming manual sample preparation. The aim of the present study was therefore to develop an automated sample-preparation protocol for the quantification of sirolimus, everolimus and tacrolimus by LC-MS/MS using a liquid handling platform. Six-level commercially available blood calibrators were used for assay development, while four quality control materials and three blood samples from patients under immunosuppressant treatment were employed for the evaluation of imprecision. Barcode reading, sample re-suspension, transfer of whole blood samples into 96-well plates, addition of internal standard solution, mixing, and protein precipitation were performed with a liquid handling platform. After plate filtration, the deproteinised supernatants were submitted for SPE on-line. The only manual steps in the entire process were de-capping of the tubes, and transfer of the well plates to the HPLC autosampler. Calibration curves were linear throughout the selected ranges. The imprecision and accuracy data for all analytes were highly satisfactory. The agreement between the results obtained with manual and those obtained with automated sample preparation was optimal (n=390, r=0.96). In daily routine (100 patient samples) the typical overall total turnaround time was less than 6h. Our findings indicate that the proposed analytical system is suitable for routine analysis, since it is straightforward and precise. Furthermore, it incurs less manual workload and less risk of error in the quantification of whole blood immunosuppressant concentrations than conventional methods. © 2013.
CTEPP STANDARD OPERATING PROCEDURE FOR HANDLING SAMPLE AND DATA CUSTODY (SOP-2.26)
This SOP describes the method for handling sample custody. A standardized Chain-of-Custody (CoC) Record is used to document the sample/data custody. Each participant is assigned one CoC Record for the samples/data collected at their home and/or day care center.
A Versatile High-Vacuum Cryo-transfer System for Cryo-microscopy and Analytics
Tacke, Sebastian; Krzyzanek, Vladislav; Nüsse, Harald; Wepf, Roger Albert; Klingauf, Jürgen; Reichelt, Rudolf
2016-01-01
Cryogenic microscopy methods have gained increasing popularity, as they offer an unaltered view on the architecture of biological specimens. As a prerequisite, samples must be handled under cryogenic conditions below their recrystallization temperature, and contamination during sample transfer and handling must be prevented. We present a high-vacuum cryo-transfer system that streamlines the entire handling of frozen-hydrated samples from the vitrification process to low temperature imaging for scanning transmission electron microscopy and transmission electron microscopy. A template for cryo-electron microscopy and multimodal cryo-imaging approaches with numerous sample transfer steps is presented. PMID:26910419
Oral biopsy: oral pathologist's perspective.
Kumaraswamy, K L; Vidhya, M; Rao, Prasanna Kumar; Mukunda, Archana
2012-01-01
Many oral lesions may need to be diagnosed by removing a sample of tissue from the oral cavity. Biopsy is widely used in the medical field, but the practice is not quite widespread in dental practice. As oral pathologists, we have found many artifacts in the tissue specimen because of poor biopsy technique or handling, which has led to diagnostic pitfalls and misery to both the patient and the clinician. This article aims at alerting the clinicians about the clinical faults arising preoperatively, intraoperatively and postoperatively while dealing with oral biopsy that may affect the histological assessment of the tissue and, therefore, the diagnosis. It also reviews the different techniques, precautions and special considerations necessary for specific lesions.
Simulator for multilevel optimization research
NASA Technical Reports Server (NTRS)
Padula, S. L.; Young, K. C.
1986-01-01
A computer program designed to simulate and improve multilevel optimization techniques is described. By using simple analytic functions to represent complex engineering analyses, the simulator can generate and test a large variety of multilevel decomposition strategies in a relatively short time. This type of research is an essential step toward routine optimization of large aerospace systems. The paper discusses the types of optimization problems handled by the simulator and gives input and output listings and plots for a sample problem. It also describes multilevel implementation techniques which have value beyond the present computer program. Thus, this document serves as a user's manual for the simulator and as a guide for building future multilevel optimization applications.
Planning and processing multistage samples with a computer programMUST.
John W. Hazard; Larry E. Stewart
1974-01-01
A computer program was written to handle multistage sampling designs in insect populations. It is, however, general enough to be used for any population where the number of stages does not exceed three. The program handles three types of sampling situations, all of which assume equal probability sampling. Option 1 takes estimates of sample variances, costs, and either...
Veterinary extension on sampling techniques related to heartwater research.
Steyn, H C; McCrindle, C M E; Du Toit, D
2010-09-01
Heartwater, a tick-borne disease caused by Ehrlichia ruminantium, is considered to be a significant cause of mortality amongst domestic and wild ruminants in South Africa. The main vector is Amblyomma hebraeum and although previous epidemiological studies have outlined endemic areas based on mortalities, these have been limited by diagnostic methods which relied mainly on positive brain smears. The indirect fluorescent antibody test (IFA) has a low specificity for heartwater organisms as it cross-reacts with some other species. Since the advent of biotechnology and genomics, molecular epidemiology has evolved using the methodology of traditional epidemiology coupled with the new molecular techniques. A new quantitative real-time polymerase chain reaction (qPCR) test has been developed for rapid and accurate diagnosis of heartwater in the live animal. This method can also be used to survey populations of A. hebraeum ticks for heartwater. Sampling whole blood and ticks for this qPCR differs from routine serum sampling, which is used for many serological tests. Veterinary field staff, particularly animal health technicians, are involved in surveillance and monitoring of controlled and other diseases of animals in South Africa. However, it was found that the sampling of whole blood was not done correctly, probably because it is a new sampling technique specific for new technology, where the heartwater organism is much more labile than the serum antibodies required for other tests. This qPCR technique is highly sensitive and can diagnose heartwater in the living animal within 2 hours, in time to treat it. Poor sampling techniques that decrease the sensitivity of the test will, however, result in a false negative diagnosis. This paper describes the development of a skills training programme for para-veterinary field staff, to facilitate research into the molecular epidemiology of heartwater in ruminants and eliminate any sampling bias due to collection errors. Humane handling techniques were also included in the training, in line with the current focus on improved livestock welfare.
Tickling, a Technique for Inducing Positive Affect When Handling Rats.
Cloutier, Sylvie; LaFollette, Megan R; Gaskill, Brianna N; Panksepp, Jaak; Newberry, Ruth C
2018-05-08
Handling small animals such as rats can lead to several adverse effects. These include the fear of humans, resistance to handling, increased injury risk for both the animals and the hands of their handlers, decreased animal welfare, and less valid research data. To minimize negative effects on experimental results and human-animal relationships, research animals are often habituated to being handled. However, the methods of habituation are highly variable and often of limited effectiveness. More potently, it is possible for humans to mimic aspects of the animals' playful rough-and-tumble behavior during handling. When applied to laboratory rats in a systematic manner, this playful handling, referred to as tickling, consistently gives rise to positive behavioral responses. This article provides a detailed description of a standardized rat tickling technique. This method can contribute to future investigations into positive affective states in animals, make it easier to handle rats for common husbandry activities such as cage changing or medical/research procedures such as injection, and be implemented as a source of social enrichment. It is concluded that this method can be used to efficiently and practicably reduce rats' fearfulness of humans and improve their welfare, as well as reliably model positive affective states.
Dynamic stability and handling qualities tests on a highly augmented, statically unstable airplane
NASA Technical Reports Server (NTRS)
Gera, Joseph; Bosworth, John T.
1987-01-01
Novel flight test and analysis techniques in the flight dynamics and handling qualities area are described. These techniques were utilized at NASA Ames-Dryden during the initial flight envelope clearance of the X-29A aircraft. It is shown that the open-loop frequency response of an aircraft with highly relaxed static stability can be successfully computed on the ground from telemetry data. Postflight closed-loop frequency response data were obtained from pilot-generated frequency sweeps and it is found that the current handling quality requirements for high-maneuverability aircraft are generally applicable to the X-29A.
Enteral Feeding Set Handling Techniques.
Lyman, Beth; Williams, Maria; Sollazzo, Janet; Hayden, Ashley; Hensley, Pam; Dai, Hongying; Roberts, Cristine
2017-04-01
Enteral nutrition therapy is common practice in pediatric clinical settings. Often patients will receive a pump-assisted bolus feeding over 30 minutes several times per day using the same enteral feeding set (EFS). This study aims to determine the safest and most efficacious way to handle the EFS between feedings. Three EFS handling techniques were compared through simulation for bacterial growth, nursing time, and supply costs: (1) rinsing the EFS with sterile water after each feeding, (2) refrigerating the EFS between feedings, and (3) using a ready-to-hang (RTH) product maintained at room temperature. Cultures were obtained at baseline, hour 12, and hour 21 of the 24-hour cycle. A time-in-motion analysis was conducted and reported in average number of seconds to complete each procedure. Supply costs were inventoried for 1 month comparing the actual usage to our estimated usage. Of 1080 cultures obtained, the overall bacterial growth rate was 8.7%. The rinse and refrigeration techniques displayed similar bacterial growth (11.4% vs 10.3%, P = .63). The RTH technique displayed the least bacterial growth of any method (4.4%, P = .002). The time analysis in minutes showed the rinse method was the most time-consuming (44.8 ± 2.7) vs refrigeration (35.8 ± 2.6) and RTH (31.08 ± 0.6) ( P < .0001). All 3 EFS handling techniques displayed low bacterial growth. RTH was superior in bacterial growth, nursing time, and supply costs. Since not all pediatric formulas are available in RTH, we conclude that refrigerating the EFS between uses is the next most efficacious method for handling the EFS between bolus feeds.
Basic technique for solid lesions: Cytology, core, or both?
Hébert-Magee, Shantel
2014-01-01
This chapter highlights key fundamentals relevant to post-procurement tissue handling of materials obtains by aspiration and/or biopsy and details the subtle techniques that can significantly impact patient management and practice patterns. A basic knowledge of tissue handling and processing is imperative for endosonographers who attempt to achieve a greater than 95% diagnostic accuracy with their tissue-acquisition procedures. PMID:24949408
Hoffmayer, Eric R; Hendon, Jill M; Parsons, Glenn R; Driggers, William B; Campbell, Matthew D
2015-10-01
Elasmobranch stress responses are traditionally measured in the field by either singly or serially sampling an animal after a physiologically stressful event. Although capture and handling techniques are effective at inducing a stress response, differences in protocols could affect the degree of stress experienced by an individual, making meaningful comparisons between the protocols difficult, if not impossible. This study acutely stressed Atlantic sharpnose sharks, Rhizoprionodon terraenovae, by standardized capture (rod and reel) and handling methods and implemented either a single or serial blood sampling protocol to monitor four indicators of the secondary stress response. Single-sampled sharks were hooked and allowed to swim around the boat until retrieved for a blood sample at either 0, 15, 30, 45, or 60 min post-hooking. Serially sampled sharks were retrieved, phlebotomized, released while still hooked, and subsequently resampled at 15, 30, 45, and 60 min intervals post-hooking. Blood was analyzed for hematocrit, and plasma glucose, lactate, and osmolality levels. Although both single and serial sampling protocols resulted in an increase in glucose, no significant difference in glucose level was found between protocols. Serially sampled sharks exhibited cumulatively heightened levels for lactate and osmolality at all time intervals when compared to single-sampled animals at the same time. Maximal concentration differences of 217.5, 9.8, and 41.6 % were reported for lactate, osmolality, and glucose levels, respectively. Hematocrit increased significantly over time for the single sampling protocol but did not change significantly during the serial sampling protocol. The differences in resultant blood chemistry levels between implemented stress protocols and durations are significant and need to be considered when assessing stress in elasmobranchs.
Comparison of Two Educational Methods on Nurses' Adoption of Safe Patient Handling Techniques
ERIC Educational Resources Information Center
Folami, Florence
2010-01-01
Musculoskeletal injuries caused by patient lifting and transfers are a concern to health care workers. The Safe Patient Handling Act calls for all health care organizations to move to mechanical assistance from previous manual methods of transfers. This research analyzed two different educational programs that addressed safe patient handling for…
This protocol describes how quality control samples should be handled in the field, and was designed as a quick reference source for the field staff. The protocol describes quality control samples for air-VOCs, air-particles, water samples, house dust, soil, urine, blood, hair, a...
Alternatives to Retroorbital Blood Collection in Hispid Cotton Rats (Sigmodon hispidus)
Ayers, Jessica D; Rota, Paul A; Collins, Marcus L; Drew, Clifton P
2012-01-01
Cotton rats (Sigmodon hispidus) are a valuable animal model for many human viral diseases, including polio virus, measles virus, respiratory syncytial virus, and herpes simplex virus. Although cotton rats have been used in research since 1939, few publications address handling and sampling techniques for this species, and the retroorbital sinus remains the recommended blood sampling site. Here we assessed blood sampling methods that are currently used in other species and a novel subzygomatic sampling site for their use in S. hispidus. The subzygomatic approach accesses a venous sinus that possibly is unique to this species and that lies just below the zygomatic arch of the maxilla and deep to the masseter muscle. We report that both the novel subzygomatic approach and the sublingual vein method can be used effectively in cotton rats. PMID:22776125
Semi-automated 96-well liquid-liquid extraction for quantitation of drugs in biological fluids.
Zhang, N; Hoffman, K L; Li, W; Rossi, D T
2000-02-01
A semi-automated liquid-liquid extraction (LLE) technique for biological fluid sample preparation was introduced for the quantitation of four drugs in rat plasma. All liquid transferring during the sample preparation was automated using a Tomtec Quadra 96 Model 320 liquid handling robot, which processed up to 96 samples in parallel. The samples were either in 96-deep-well plate or tube-rack format. One plate of samples can be prepared in approximately 1.5 h, and the 96-well plate is directly compatible with the autosampler of an LC/MS system. Selection of organic solvents and recoveries are discussed. Also, precision, relative error, linearity and quantitation of the semi automated LLE method are estimated for four example drugs using LC/MS/MS with a multiple reaction monitoring (MRM) approach. The applicability of this method and future directions are evaluated.
A manipulator arm for zero-g simulations
NASA Technical Reports Server (NTRS)
Brodie, S. B.; Grant, C.; Lazar, J. J.
1975-01-01
A 12-ft counterbalanced Slave Manipulator Arm (SMA) was designed and fabricated to be used for resolving the questions of operational applications, capabilities, and limitations for such remote manned systems as the Payload Deployment and Retrieval Mechanism (PDRM) for the shuttle, the Free-Flying Teleoperator System, the Advanced Space Tug, and Planetary Rovers. As a developmental tool for the shuttle manipulator system (or PDRM), the SMA represents an approximate one-quarter scale working model for simulating and demonstrating payload handling, docking assistance, and satellite servicing. For the Free-Flying Teleoperator System and the Advanced Tug, the SMA provides a near full-scale developmental tool for satellite servicing, docking, and deployment/retrieval procedures, techniques, and support equipment requirements. For the Planetary Rovers, it provides an oversize developmental tool for sample handling and soil mechanics investigations. The design of the SMA was based on concepts developed for a 40-ft NASA technology arm to be used for zero-g shuttle manipulator simulations.
Milutinović, Dragana; Andrijević, Ilija; Ličina, Milijana; Andrijević, Ljiljana
2015-01-01
Introduction This study aimed to assess confidence level of healthcare professionals in venipuncture and their knowledge on the possible causes of in vitro hemolysis. Materials and methods A sample of 94 healthcare professionals (nurses and laboratory technicians) participated in this survey study. A four-section questionnaire was used as a research instrument comprising general information for research participants, knowledge on possible causes of in vitro hemolysis due to type of material used and venipuncture technique and specimen handling, as well as assessment of healthcare professionals’ confidence level in their own ability to perform first and last venipuncture. Results The average score on the knowledge test was higher in nurses’ than in laboratory technicians (8.11 ± 1.7, and 7.4 ± 1.5, respectively). The difference in average scores was statistically significant (P = 0.035) and Cohen’s d in the range of 0.4 indicates that there is a moderate difference on the knowledge test among the health care workers. Only 11/94 of healthcare professionals recognized that blood sample collection from cannula and evacuated tube is method which contributes most to the occurrence of in vitro hemolysis, whereas most risk factors affecting occurrence of in vitro hemolysis during venipuncture were recognized. There were no significant differences in mean score on the knowledge test in relation to the confidence level in venipuncture (P = 0.551). Conclusion Confidence level at last venipuncture among both profiles of healthcare staff was very high, but they showed insufficient knowledge about possible factors affecting hemolysis due to materials used in venipuncture compared with factors due to venipuncture technique and handling of blood sample. PMID:26527124
19 CFR 151.29 - Expense of unlading and handling.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Molasses § 151.29 Expense of unlading and handling. No expense incidental to the unlading, transporting, or handling of sugar, sirup, or molasses for convenient weighing, gaging, measuring, sampling, or marking...
19 CFR 151.29 - Expense of unlading and handling.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Molasses § 151.29 Expense of unlading and handling. No expense incidental to the unlading, transporting, or handling of sugar, sirup, or molasses for convenient weighing, gaging, measuring, sampling, or marking...
High-throughput microtitre plate-based assay for DNA topoisomerases.
Taylor, James A; Burton, Nicolas P; Maxwell, Anthony
2012-01-01
We have developed a rapid, high-throughput assay for measuring the catalytic activity (DNA supercoiling or relaxation) of DNA topoisomerases. The assay utilizes intermolecular triplex formation between an immobilized triplex-forming oligo (TFO) and a triplex-forming region inserted into the plasmid substrate (pNO1), and capitalizes on the observation that supercoiled DNA forms triplexes more readily than relaxed DNA. Thus, supercoiled DNA is preferentially retained by the TFO under triplex-forming conditions while relaxed DNA can be washed away. Due to its high speed of sample analysis and reduced sample handling over conventional gel-based techniques, this assay can be used to screen chemical libraries for novel inhibitors of topoisomerases.
Earth resources sensor data handling system: NASA JSC version
NASA Technical Reports Server (NTRS)
1974-01-01
The design of the NASA JSC data handling system is presented. Data acquisition parameters and computer display formats and the flow of image data through the system, with recommendations for improving system efficiency are discussed along with modifications to existing data handling procedures which will allow utilization of data duplication techniques and the accurate identification of imagery.
Ride quality sensitivity to SAS control law and to handling quality variations
NASA Technical Reports Server (NTRS)
Roberts, P. A.; Schmidt, D. K.; Swaim, R. L.
1976-01-01
The RQ trends which large flexible aircraft exhibit under various parameterizations of control laws and handling qualities are discussed. A summary of the assumptions and solution technique, a control law parameterization review, a discussion of ride sensitivity to handling qualities, and the RQ effects generated by implementing relaxed static stability configurations are included.
Thermal inactivation of enzymes and pathogens in biosamples for MS analysis.
Ahnoff, Martin; Cazares, Lisa H; Sköld, Karl
2015-01-01
Protein denaturation is the common basis for enzyme inactivation and inactivation of pathogens, necessary for preservation and safe handling of biosamples for downstream analysis. While heat-stabilization technology has been used in proteomic and peptidomic research since its introduction in 2009, the advantages of using the technique for simultaneous pathogen inactivation have only recently been addressed. The time required for enzyme inactivation by heat (≈1 min) is short compared with chemical treatments, and inactivation is irreversible in contrast to freezing. Heat stabilization thus facilitates mass spectrometric studies of biomolecules with a fast conversion rate, and expands the chemical space of potential biomarkers to include more short-lived entities, such as phosphorylated proteins, in tissue samples as well as whole-blood (dried blood sample) samples.
Rare cell isolation and analysis in microfluidics
Chen, Yuchao; Li, Peng; Huang, Po-Hsun; Xie, Yuliang; Mai, John D.; Wang, Lin; Nguyen, Nam-Trung; Huang, Tony Jun
2014-01-01
Rare cells are low-abundance cells in a much larger population of background cells. Conventional benchtop techniques have limited capabilities to isolate and analyze rare cells because of their generally low selectivity and significant sample loss. Recent rapid advances in microfluidics have been providing robust solutions to the challenges in the isolation and analysis of rare cells. In addition to the apparent performance enhancements resulting in higher efficiencies and sensitivity levels, microfluidics provides other advanced features such as simpler handling of small sample volumes and multiplexing capabilities for high-throughput processing. All of these advantages make microfluidics an excellent platform to deal with the transport, isolation, and analysis of rare cells. Various cellular biomarkers, including physical properties, dielectric properties, as well as immunoaffinities, have been explored for isolating rare cells. In this Focus article, we discuss the design considerations of representative microfluidic devices for rare cell isolation and analysis. Examples from recently published works are discussed to highlight the advantages and limitations of the different techniques. Various applications of these techniques are then introduced. Finally, a perspective on the development trends and promising research directions in this field are proposed. PMID:24406985
Elimination of ``memory`` from sample handling and inlet system of a mass spectrometer
Chastgner, P.
1991-05-08
This paper describes a method for preparing the sample handling and inlet system of a mass spectrometer for analysis of a subsequent sample following analysis of a previous sample comprising the flushing of the system interior with supercritical CO{sub 2} and venting the interior. The method eliminates the effect of system ``memory`` on the subsequent analysis, especially following persistent samples such as xenon and krypton.
Tail-Cuff Technique and Its Influence on Central Blood Pressure in the Mouse.
Wilde, Elena; Aubdool, Aisah A; Thakore, Pratish; Baldissera, Lineu; Alawi, Khadija M; Keeble, Julie; Nandi, Manasi; Brain, Susan D
2017-06-27
Reliable measurement of blood pressure in conscious mice is essential in cardiovascular research. Telemetry, the "gold-standard" technique, is invasive and expensive and therefore tail-cuff, a noninvasive alternative, is widely used. However, tail-cuff requires handling and restraint during measurement, which may cause stress affecting blood pressure and undermining reliability of the results. C57Bl/6J mice were implanted with radio-telemetry probes to investigate the effects of the steps of the tail-cuff technique on central blood pressure, heart rate, and temperature. This included comparison of handling techniques, operator's sex, habituation, and influence of hypertension induced by angiotensin II. Direct comparison of measurements obtained by telemetry and tail-cuff were made in the same mouse. The results revealed significant increases in central blood pressure, heart rate, and core body temperature from baseline following handling interventions without significant difference among the different handling technique, habituation, or sex of the investigator. Restraint induced the largest and sustained increase in cardiovascular parameters and temperature. The tail-cuff readings significantly underestimated those from simultaneous telemetry recordings; however, "nonsimultaneous" telemetry, obtained in undisturbed mice, were similar to tail-cuff readings obtained in undisturbed mice on the same day. This study reveals that the tail-cuff technique underestimates the core blood pressure changes that occur simultaneously during the restraint and measurement phases. However, the measurements between the 2 techniques are similar when tail-cuff readings are compared with telemetry readings in the nondisturbed mice. The differences between the simultaneous recordings by the 2 techniques should be recognized by researchers. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Highly oriented carbon fiber–polymer composites via additive manufacturing
Tekinalp, Halil L.; Kunc, Vlastimil; Velez-Garcia, Gregorio M.; ...
2014-10-16
Additive manufacturing, diverging from traditional manufacturing techniques, such as casting and machining materials, can handle complex shapes with great design flexibility without the typical waste. Although this technique has been mainly used for rapid prototyping, interest is growing in using this method to directly manufacture actual parts of complex shape. To use 3D-printing additive manufacturing in wide spread applications, the technique and the feedstock materials require improvements to meet the mechanical requirements of load-bearing components. Thus, we investigated the short fiber (0.2 mm to 0.4 mm) reinforced acrylonitrile-butadiene-styrene composites as a feedstock for 3D-printing in terms of their processibility, microstructuremore » and mechanical performance; and also provided comparison with traditional compression molded composites. The tensile strength and modulus of 3D-printed samples increased ~115% and ~700%, respectively. 3D-printer yielded samples with very high fiber orientation in printing direction (up to 91.5 %), whereas, compression molding process yielded samples with significantly less fiber orientation. Microstructure-mechanical property relationships revealed that although the relatively high porosity is observed in the 3D-printed composites as compared to those produced by the conventional compression molding technique, they both exhibited comparable tensile strength and modulus. Furthermore, this phenomena is explained based on the changes in fiber orientation, dispersion and void formation.« less
Airborne microorganisms associated with grain handling.
Swan, J R; Crook, B
1998-01-01
There is substantial evidence that workers handling grain develop allergic respiratory symptoms. Microbiological contaminants are likely to be a significant contributing factor. Worker's exposure to microorganisms contaminating grain dust in the UK was therefore examined. Aerobiological studies were made when grain was being handled on farms and also during bulk handling of grain in dockside terminals. A quantitative and qualitative microbiological examination of the airborne grain dust was carried out. Samples of airborne grain dust were collected and viable bacteria, fungi and actinomycetes were grown, isolated and identified. It was found that workers handling grain or working close to grain at farms and docks were frequently exposed to more than 1 million bacteria and fungi per m3 air, and that airborne bacteria and fungi exceeded 10(4) per m3 air in all areas sampled. The qualitative examination of the samples showed that the predominant microorganisms present differed between freshly harvested grain and stored grain, but not between different types of grain.
A Data-Centric Strategy for Modern Biobanking.
Quinlan, Philip R; Gardner, Stephen; Groves, Martin; Emes, Richard; Garibaldi, Jonathan
2015-01-01
Biobanking has been in existence for many decades and over that time has developed significantly. Biobanking originated from a need to collect, store and make available biological samples for a range of research purposes. It has changed as the understanding of biological processes has increased and new sample handling techniques have been developed to ensure samples were fit-for-purpose.As a result of these developments, modern biobanking is now facing two substantial new challenges. Firstly, new research methods such as next generation sequencing can generate datasets that are at an infinitely greater scale and resolution than previous methods. Secondly, as the understanding of diseases increases researchers require a far richer data set about the donors from which the sample originate.To retain a sample-centric strategy in a research environment that is increasingly dictated by data will place a biobank at a significant disadvantage and even result in the samples collected going unused. As a result biobanking is required to change strategic focus from a sample dominated perspective to a data-centric strategy.
SAMPLE COLLECTION AND HANDLING FOR MICROBIOLOGICAL EXAMINATION OF BIOSOLIDS
The objective of this presentation is to discuss sample collection and handling methods currently in use for detection and enumeration of microorganisms in biosolids and municipal wastewater sludges. Untreated sludges and biosolids are rarely homogeneous and present a challenge ...
Caring for Your Videodiscs, CD-ROM Discs, and Players.
ERIC Educational Resources Information Center
Ekhaml, Leticia; Saygan, Bobby
1993-01-01
Presents guidelines for the proper care and handling of videodisc and CD-ROM hardware and software. Topics discussed include handling the equipment, moving, cleaning techniques, storage considerations, ventilation requirements, and climate control. (LRW)
Rohman, A; Man, Yb Che; Sismindari
2009-10-01
Today, virgin coconut oil (VCO) is becoming valuable oil and is receiving an attractive topic for researchers because of its several biological activities. In cosmetics industry, VCO is excellent material which functions as a skin moisturizer and softener. Therefore, it is important to develop a quantitative analytical method offering a fast and reliable technique. Fourier transform infrared (FTIR) spectroscopy with sample handling technique of attenuated total reflectance (ATR) can be successfully used to analyze VCO quantitatively in cream cosmetic preparations. A multivariate analysis using calibration of partial least square (PLS) model revealed the good relationship between actual value and FTIR-predicted value of VCO with coefficient of determination (R2) of 0.998.
THE PASSAGE OF MARKED IONS INTO TISSUES AND FLUIDS OF THE REPRODUCTIVE TRACT OF PREGNANT RABBITS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bennett, J.P.; Boursnell, J.C.; Lutwak-Mann, C.
1959-10-31
Rapid changes were demonstrated in the uptake of labeled ions both in the developing embryo and in the endometrium, mesodermal placental folds, and other closely associated tissues and fluids following the intravenous injection of labeled ions in pregnant rabbits. Phosphorus-32, sulfur-85, sodium-24, iodine- 131, and potassium-42 were used as tracers. A number of new techniques were developed to obtain, weigh, and handle the extremely small samples. The influence of exogenous materials on the early development of fetuses is discussed briefly. (C.R.)
Ground data handling for Landsat-D. [for thematic mapper
NASA Technical Reports Server (NTRS)
Lynch, T. J.
1977-01-01
The present plans for the Landsat-D ground data handling are described in relationship to the mission objectives and the planned spacecraft system. The end-to-end data system is presented with particular emphasis on the data handling plans for the new instrument, the Thematic Mapper. This instrument generates ten times the amount of data per scene as the present Multispectral Scanner and this resulting data rate and volume are discussed as well as possible new data techniques to handle them - such as image compression.
Ground data handling for LANDSAT-D
NASA Technical Reports Server (NTRS)
Lynch, T. J.
1976-01-01
The present plans for the LANDSAT D ground data handling are described in relationship to the mission objectives and the planned spacecraft system. The end to end data system is presented with particular emphasis on the data handling plans for the new instrument, the Thematic Mapper. This instrument generates ten times the amount of data per scene as the present Multispectral Scanner, and this resulting data rate and volume are discussed as well as possible new data techniques to handle them such as image compression.
Mooring and ground handling rigid airships
NASA Technical Reports Server (NTRS)
Walker, H., Jr.
1975-01-01
The problems of mooring and ground handling rigid airships are discussed. A brief history of Mooring and Ground Handling Rigid Airships from July 2, 1900 through September 1, 1939 is included. Also a brief history of ground handling developments with large U. S. Navy nonrigid airships between September 1, 1939 and August 31, 1962 is included wherein developed equipment and techniques appear applicable to future large rigid airships. Finally recommendations are made pertaining to equipment and procedures which appear desirable and feasible for future rigid airship programs.
This protocol describes the procedures for weighing, handling, and archiving aerosol filters and for managing the associated analytical and quality assurance data. Filter samples were weighed for aerosol mass at RTI laboratory, with only the automated field sampling data transfer...
Serologic and hematologic values of wild coyotes in Wisconsin
Smith, G.J.; Rongstad, O.J.
1980-01-01
Blood samples were obtained from 30 coyotes (Canis latrans) captured in northern Wisconsin in conjunction with radio-telemetry studies. Samples were assayed for seven hematologic values, seven serum chemistries, serum albumin, globulin and total protein. Results are given with respect to sex and age and are compared with available data for captive wild and pen-raised coyotes. Leukocyte counts were greater for males than females and packed cell volumes were greater for adults than young, possibly due to differential response to capture and handling stress. Hemoglobin concentrations and calcium levels suggest differences in nutrition between pen-raised and wild coyotes. Sex and age differences in serum calcium for wild coyotes probably reflect nutritional differences between groups examined. Juvenile coyote serum alkaline phosphatase levels declined curvilinearly with age for coyotes less than one year old, suggesting a possible technique for separating juveniles and yearlings captured in autumn that are released for research purposes. Elevated glucose levels and leukocyte counts in wild coyotes may reflect greater handling stress than for pen-raised and captive coyotes. No significant sex or age effects were found for levels of serum urea nitrogen, total protein, cholesterol, and total bilirubin.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sexton, L.
2012-06-06
Environmental sampling has become a key component of International Atomic Energy Agency (IAEA) safeguards approaches since its approval for use in 1996. Environmental sampling supports the IAEA's mission of drawing conclusions concerning the absence of undeclared nuclear material or nuclear activities in a Nation State. Swipe sampling is the most commonly used method for the collection of environmental samples from bulk handling facilities. However, augmenting swipe samples with an air monitoring system, which could continuously draw samples from the environment of bulk handling facilities, could improve the possibility of the detection of undeclared activities. Continuous sampling offers the opportunity tomore » collect airborne materials before they settle onto surfaces which can be decontaminated, taken into existing duct work, filtered by plant ventilation, or escape via alternate pathways (i.e. drains, doors). Researchers at the Savannah River National Laboratory and Oak Ridge National Laboratory have been working to further develop an aerosol collection technology that could be installed at IAEA safeguarded bulk handling facilities. The addition of this technology may reduce the number of IAEA inspector visits required to effectively collect samples. The principal sample collection device is a patented Aerosol Contaminant Extractor (ACE) which utilizes electrostatic precipitation principles to deposit particulates onto selected substrates. Recent work has focused on comparing traditional swipe sampling to samples collected via an ACE system, and incorporating tamper resistant and tamper indicating (TRI) technologies into the ACE system. Development of a TRI-ACE system would allow collection of samples at uranium/plutonium bulk handling facilities in a manner that ensures sample integrity and could be an important addition to the international nuclear safeguards inspector's toolkit. This work was supported by the Next Generation Safeguards Initiative (NGSI), Office of Nonproliferation and International Security (NIS), National Nuclear Security Administration (NNSA).« less
Mrayyan, Majd T; Modallal, Rola; Awamreh, Khitam; Atoum, Maysoun; Abdullah, Muna; Suliman, Samah
2008-03-01
This study examined the perceptions of 62 senior nursing students of the readiness of Jordanian organizations for change, students' motivators and their conflict-handling intentions. Such concepts should be taught at Schools of Nursing in order to prepare the students as nurses in the near future. It is found that the course of "Nursing Leadership and Management" has positive influence on students' understanding of the studied concepts. This descriptive study was conducted in seven hospitals. Grossman and Valiga's (2000) [Grossman, S., Valiga, T.M., 2000. The New Leadership Challenge: Creating the Future of Nursing. F.A. Davis, Philadelphia, pp. 147-148.] instrument was used to measure the readiness of organizations for change. As they progress in the course, the students' perceptions about the organizational readiness to change increased; the students "somehow" perceived that the Jordanian organizations were ready to change. The students were asked what motivates and they were asked about their conflict-handling techniques. Senior nursing students reported that private hospitals were better than governmental hospitals in their readiness for change. In general, male students perceived the readiness of organizations for change more positively than female students. The students were mainly motivated by "achievement" and used "collaboration" as a primary conflict-handling technique. Further studies are needed to explore in-depth the concept of the readiness of organizations for change. Achievement is a strong motivator that should be encouraged among students. Conflict-handling techniques in general and collaboration in particular should be taught for nursing students as these techniques will influence their future professional lives.
Optimization of a Viability PCR Method for the Detection of Listeria monocytogenes in Food Samples.
Agustí, Gemma; Fittipaldi, Mariana; Codony, Francesc
2018-06-01
Rapid detection of Listeria and other microbial pathogens in food is an essential part of quality control and it is critical for ensuring the safety of consumers. Culture-based methods for detecting foodborne pathogens are time-consuming, laborious and cannot detect viable but non-culturable microorganism, whereas viability PCR methodology provides quick results; it is able to detect viable but non-culturable cells, and allows for easier handling of large amount of samples. Although the most critical point to use viability PCR technique is achieving the complete exclusion of dead cell amplification signals, many improvements are being introduced to overcome this. In the present work, the yield of dead cell DNA neutralization was enhanced by incorporating two new sample treatment strategies: tube change combined with a double light treatment. This procedure was successfully tested using artificially contaminated food samples, showing improved neutralization of dead cell DNA.
Optimizing Integrated Terminal Airspace Operations Under Uncertainty
NASA Technical Reports Server (NTRS)
Bosson, Christabelle; Xue, Min; Zelinski, Shannon
2014-01-01
In the terminal airspace, integrated departures and arrivals have the potential to increase operations efficiency. Recent research has developed geneticalgorithm- based schedulers for integrated arrival and departure operations under uncertainty. This paper presents an alternate method using a machine jobshop scheduling formulation to model the integrated airspace operations. A multistage stochastic programming approach is chosen to formulate the problem and candidate solutions are obtained by solving sample average approximation problems with finite sample size. Because approximate solutions are computed, the proposed algorithm incorporates the computation of statistical bounds to estimate the optimality of the candidate solutions. A proof-ofconcept study is conducted on a baseline implementation of a simple problem considering a fleet mix of 14 aircraft evolving in a model of the Los Angeles terminal airspace. A more thorough statistical analysis is also performed to evaluate the impact of the number of scenarios considered in the sampled problem. To handle extensive sampling computations, a multithreading technique is introduced.
Investigation of a high speed data handling system for use with multispectral aircraft scanners
NASA Technical Reports Server (NTRS)
Kelly, W. L.; Meredith, B. D.
1978-01-01
A buffer memory data handling technique for use with multispectral aircraft scanners is presented which allows digital data generated at high data rates to be recorded on magnetic tape. A digital memory is used to temporarily store the data for subsequent recording at slower rates during the passive time of the scan line, thereby increasing the maximum data rate recording capability over real-time recording. Three possible implementations are described and the maximum data rate capability is defined in terms of the speed capability of the key hardware components. The maximum data rates can be used to define the maximum ground resolution achievable by a multispectral aircraft scanner using conventional data handling techniques.
Analysis of aircraft longitudinal handling qualities
NASA Technical Reports Server (NTRS)
Hess, R. A.
1981-01-01
The optimal control model (OCM) of the human pilot is applied to the study of aircraft handling qualities. Attention is focused primarily on longitudinal tasks. The modeling technique differs from previous applications of the OCM in that considerable effort is expended in simplifying the pilot/vehicle analysis. After briefly reviewing the OCM, a technique for modeling the pilot controlling higher order systems is introduced. Following this, a simple criterion for determining the susceptibility of an aircraft to pilot induced oscillations (PIO) is formulated. Finally, a model-based metric for pilot rating prediction is discussed. The resulting modeling procedure provides a relatively simple, yet unified approach to the study of a variety of handling qualities problems.
Prediction of aircraft handling qualities using analytical models of the human pilot
NASA Technical Reports Server (NTRS)
Hess, R. A.
1982-01-01
The optimal control model (OCM) of the human pilot is applied to the study of aircraft handling qualities. Attention is focused primarily on longitudinal tasks. The modeling technique differs from previous applications of the OCM in that considerable effort is expended in simplifying the pilot/vehicle analysis. After briefly reviewing the OCM, a technique for modeling the pilot controlling higher order systems is introduced. Following this, a simple criterion for determining the susceptibility of an aircraft to pilot-induced oscillations (PIO) is formulated. Finally, a model-based metric for pilot rating prediction is discussed. The resulting modeling procedure provides a relatively simple, yet unified approach to the study of a variety of handling qualities problems.
Prediction of aircraft handling qualities using analytical models of the human pilot
NASA Technical Reports Server (NTRS)
Hess, R. A.
1982-01-01
The optimal control model (OCM) of the human pilot is applied to the study of aircraft handling qualities. Attention is focused primarily on longitudinal tasks. The modeling technique differs from previous applications of the OCM in that considerable effort is expended in simplifying the pilot/vehicle analysis. After briefly reviewing the OCM, a technique for modeling the pilot controlling higher order systems is introduced. Following this, a simple criterion for determining the susceptibility of an aircraft to pilot induced oscillations is formulated. Finally, a model based metric for pilot rating prediction is discussed. The resulting modeling procedure provides a relatively simple, yet unified approach to the study of a variety of handling qualities problems.
Constraint Embedding for Multibody System Dynamics
NASA Technical Reports Server (NTRS)
Jain, Abhinandan
2009-01-01
This paper describes a constraint embedding approach for the handling of local closure constraints in multibody system dynamics. The approach uses spatial operator techniques to eliminate local-loop constraints from the system and effectively convert the system into tree-topology systems. This approach allows the direct derivation of recursive O(N) techniques for solving the system dynamics and avoiding the expensive steps that would otherwise be required for handling the closedchain dynamics. The approach is very effective for systems where the constraints are confined to small-subgraphs within the system topology. The paper provides background on the spatial operator O(N) algorithms, the extensions for handling embedded constraints, and concludes with some examples of such constraints.
Salo, Hanna; Berisha, Anna-Kaisa; Mäkinen, Joni
2016-03-01
This is the first study seasonally applying Sphagnum papillosum moss bags and vertical snow samples for monitoring atmospheric pollution. Moss bags, exposed in January, were collected together with snow samples by early March 2012 near the Harjavalta Industrial Park in southwest Finland. Magnetic, chemical, scanning electron microscopy-energy dispersive X-ray spectroscopy (SEM-EDX), K-means clustering, and Tomlinson pollution load index (PLI) data showed parallel spatial trends of pollution dispersal for both materials. Results strengthen previous findings that concentrate and slag handling activities were important (dust) emission sources while the impact from Cu-Ni smelter's pipe remained secondary at closer distances. Statistically significant correlations existed between the variables of snow and moss bags. As a summary, both methods work well for sampling and are efficient pollutant accumulators. Moss bags can be used also in winter conditions and they provide more homogeneous and better controlled sampling method than snow samples. Copyright © 2015. Published by Elsevier B.V.
Astrobiology Objectives for Mars Sample Return
NASA Astrophysics Data System (ADS)
Meyer, M. A.
2002-05-01
Astrobiology is the study of life in the Universe, and a major objective is to understand the past, present, and future biologic potential of Mars. The current Mars Exploration Program encompasses a series of missions for reconnaissance and in-situ analyses to define in time and space the degree of habitability on Mars. Determining whether life ever existed on Mars is a more demanding question as evidenced by controversies concerning the biogenicity of features in the Mars meteorite ALH84001 and in the earliest rocks on Earth. In-situ studies may find samples of extreme interest but resolution of the life question most probably would require a sample returned to Earth. A selected sample from Mars has the many advantages: State-of-the-art instruments, precision sample handling and processing, scrutiny by different investigators employing different techniques, and adaptation of approach to any surprises It is with a returned sample from Mars that Astrobiology has the most to gain in determining whether life did, does, or could exist on Mars.
Struwe, Weston B; Agravat, Sanjay; Aoki-Kinoshita, Kiyoko F; Campbell, Matthew P; Costello, Catherine E; Dell, Anne; Ten Feizi; Haslam, Stuart M; Karlsson, Niclas G; Khoo, Kay-Hooi; Kolarich, Daniel; Liu, Yan; McBride, Ryan; Novotny, Milos V; Packer, Nicolle H; Paulson, James C; Rapp, Erdmann; Ranzinger, Rene; Rudd, Pauline M; Smith, David F; Tiemeyer, Michael; Wells, Lance; York, William S; Zaia, Joseph; Kettner, Carsten
2016-09-01
The minimum information required for a glycomics experiment (MIRAGE) project was established in 2011 to provide guidelines to aid in data reporting from all types of experiments in glycomics research including mass spectrometry (MS), liquid chromatography, glycan arrays, data handling and sample preparation. MIRAGE is a concerted effort of the wider glycomics community that considers the adaptation of reporting guidelines as an important step towards critical evaluation and dissemination of datasets as well as broadening of experimental techniques worldwide. The MIRAGE Commission published reporting guidelines for MS data and here we outline guidelines for sample preparation. The sample preparation guidelines include all aspects of sample generation, purification and modification from biological and/or synthetic carbohydrate material. The application of MIRAGE sample preparation guidelines will lead to improved recording of experimental protocols and reporting of understandable and reproducible glycomics datasets. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Assertion: A Technique for Handling Troublesome Library Patrons.
ERIC Educational Resources Information Center
Groark, James J.
1979-01-01
Encourages the use of assertion training for librarians to aid them in providing reference service, interviewing for employment, and handling difficult patrons. A list of references and a selection of readers' comments on the article is included. (FM)
NASA Astrophysics Data System (ADS)
Liu, Robin H.; Lodes, Mike; Fuji, H. Sho; Danley, David; McShea, Andrew
Microarray assays typically involve multistage sample processing and fluidic handling, which are generally labor-intensive and time-consuming. Automation of these processes would improve robustness, reduce run-to-run and operator-to-operator variation, and reduce costs. In this chapter, a fully integrated and self-contained microfluidic biochip device that has been developed to automate the fluidic handling steps for microarray-based gene expression or genotyping analysis is presented. The device consists of a semiconductor-based CustomArray® chip with 12,000 features and a microfluidic cartridge. The CustomArray was manufactured using a semiconductor-based in situ synthesis technology. The micro-fluidic cartridge consists of microfluidic pumps, mixers, valves, fluid channels, and reagent storage chambers. Microarray hybridization and subsequent fluidic handling and reactions (including a number of washing and labeling steps) were performed in this fully automated and miniature device before fluorescent image scanning of the microarray chip. Electrochemical micropumps were integrated in the cartridge to provide pumping of liquid solutions. A micromixing technique based on gas bubbling generated by electrochemical micropumps was developed. Low-cost check valves were implemented in the cartridge to prevent cross-talk of the stored reagents. Gene expression study of the human leukemia cell line (K562) and genotyping detection and sequencing of influenza A subtypes have been demonstrated using this integrated biochip platform. For gene expression assays, the microfluidic CustomArray device detected sample RNAs with a concentration as low as 0.375 pM. Detection was quantitative over more than three orders of magnitude. Experiment also showed that chip-to-chip variability was low indicating that the integrated microfluidic devices eliminate manual fluidic handling steps that can be a significant source of variability in genomic analysis. The genotyping results showed that the device identified influenza A hemagglutinin and neuraminidase subtypes and sequenced portions of both genes, demonstrating the potential of integrated microfluidic and microarray technology for multiple virus detection. The device provides a cost-effective solution to eliminate labor-intensive and time-consuming fluidic handling steps and allows microarray-based DNA analysis in a rapid and automated fashion.
Phase-locked-loop interferometry applied to aspheric testing with a computer-stored compensator.
Servin, M; Malacara, D; Rodriguez-Vera, R
1994-05-01
A recently developed technique for continuous-phase determination of interferograms with a digital phase-locked loop (PLL) is applied to the null testing of aspheres. Although this PLL demodulating scheme is also a synchronous or direct interferometric technique, the separate unwrapping process is not explicitly required. The unwrapping and the phase-detection processes are achieved simultaneously within the PLL. The proposed method uses a computer-generated holographic compensator. The holographic compensator does not need to be printed out by any means; it is calculated and used from the computer. This computer-stored compensator is used as the reference signal to phase demodulate a sample interferogram obtained from the asphere being tested. Consequently the demodulated phase contains information about the wave-front departures from the ideal computer-stored aspheric interferogram. Wave-front differences of ~ 1 λ are handled easily by the proposed PLL scheme. The maximum recorded frequency in the template's interferogram as well as in the sampled interferogram are assumed to be below the Nyquist frequency.
Apparatus to collect, classify, concentrate, and characterize gas-borne particles
Rader, Daniel J.; Torczynski, John R.; Wally, Karl; Brockmann, John E.
2002-01-01
An aerosol lab-on-a-chip (ALOC) integrates one or more of a variety of aerosol collection, classification, concentration (enrichment), and characterization processes onto a single substrate or layered stack of such substrates. By taking advantage of modern micro-machining capabilities, an entire suite of discrete laboratory aerosol handling and characterization techniques can be combined in a single portable device that can provide a wealth of data on the aerosol being sampled. The ALOC offers parallel characterization techniques and close proximity of the various characterization modules helps ensure that the same aerosol is available to all devices (dramatically reducing sampling and transport errors). Micro-machine fabrication of the ALOC significantly reduces unit costs relative to existing technology, and enables the fabrication of small, portable ALOC devices, as well as the potential for rugged design to allow operation in harsh environments. Miniaturization also offers the potential of working with smaller particle sizes and lower pressure drops (leading to reduction of power consumption).
A sampling device with a capped body and detachable handle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jezek, Gerd-Rainer
1997-12-01
The present invention relates to a device for sampling radioactive waste and more particularly to a device for sampling radioactive waste which prevents contamination of a sampled material and the environment surrounding the sampled material. During vitrification of nuclear wastes, it is necessary to remove contamination from the surfaces of canisters filled with radioactive glass. After removal of contamination, a sampling device is used to test the surface of the canister. The one piece sampling device currently in use creates a potential for spreading contamination during vitrification operations. During operations, the one piece sampling device is transferred into and outmore » of the vitrification cell through a transfer drawer. Inside the cell, a remote control device handles the sampling device to wipe the surface of the canister. A one piece sampling device can be contaminated by the remote control device prior to use. Further, the sample device can also contaminate the transfer drawer producing false readings for radioactive material. The present invention overcomes this problem by enclosing the sampling pad in a cap. The removable handle is reused which reduces the amount of waste material.« less
Self-digitization microfluidic chip for absolute quantification of mRNA in single cells.
Thompson, Alison M; Gansen, Alexander; Paguirigan, Amy L; Kreutz, Jason E; Radich, Jerald P; Chiu, Daniel T
2014-12-16
Quantification of mRNA in single cells provides direct insight into how intercellular heterogeneity plays a role in disease progression and outcomes. Quantitative polymerase chain reaction (qPCR), the current gold standard for evaluating gene expression, is insufficient for providing absolute measurement of single-cell mRNA transcript abundance. Challenges include difficulties in handling small sample volumes and the high variability in measurements. Microfluidic digital PCR provides far better sensitivity for minute quantities of genetic material, but the typical format of this assay does not allow for counting of the absolute number of mRNA transcripts samples taken from single cells. Furthermore, a large fraction of the sample is often lost during sample handling in microfluidic digital PCR. Here, we report the absolute quantification of single-cell mRNA transcripts by digital, one-step reverse transcription PCR in a simple microfluidic array device called the self-digitization (SD) chip. By performing the reverse transcription step in digitized volumes, we find that the assay exhibits a linear signal across a wide range of total RNA concentrations and agrees well with standard curve qPCR. The SD chip is found to digitize a high percentage (86.7%) of the sample for single-cell experiments. Moreover, quantification of transferrin receptor mRNA in single cells agrees well with single-molecule fluorescence in situ hybridization experiments. The SD platform for absolute quantification of single-cell mRNA can be optimized for other genes and may be useful as an independent control method for the validation of mRNA quantification techniques.
NASA Space Program experience in hydrogen transportation and handling
NASA Technical Reports Server (NTRS)
Bain, A. L.
1976-01-01
This paper portrays the experience gained in the transportation and handling of hydrogen in support of the Apollo launch site at Kennedy Space Center (KSC), Fla., one of NASA's prime hydrogen users in the Space Program. The objective of the paper is basically to reveal the types of systems involved in handling hydrogen, safety practices, operational techniques, other general experience information, and primarily to convey the routinism by which this potential fuel of the future has already been handled in significant quantities for a number of years.
Snyman, Celia; Elliott, Edith
2011-12-15
The hanging drop three-dimensional culture technique allows cultivation of functional three-dimensional mammary constructs without exogenous extracellular matrix. The fragile acini are, however, difficult to preserve during processing steps for advanced microscopic investigation. We describe adaptations to the protocol for handling of hanging drop cultures to include investigation using confocal, scanning, and electron microscopy, with minimal loss of cell culture components. Copyright © 2011 Elsevier Inc. All rights reserved.
21 CFR 203.32 - Drug sample storage and handling requirements.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Drug sample storage and handling requirements. 203.32 Section 203.32 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... contamination, deterioration, and adulteration. (b) Compliance with compendial and labeling requirements...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Srivastava, Nimisha; Singh, Anup K
Microfluidic devices and methods for flow cytometry are described. In described examples, various sample handling and preparation steps may be carried out within a same microfluidic device as flow cytometry steps. A combination of imaging and flow cytometry is described. In some examples, spiral microchannels serve as incubation chambers. Examples of automated sample handling and flow cytometry are described.
40 CFR 86.317-79 - Hydrocarbon analyzer specifications.
Code of Federal Regulations, 2012 CFR
2012-07-01
... flame ionization detector (HFID) analyzer. (b) Option. A non-heated flame ionization detector (FID) that... temperature oven housing the detector and sample-handling components. It shall maintain temperature with 2 °C of the set point. The detector, oven, and sample-handling components within the oven shall be...
40 CFR 86.317-79 - Hydrocarbon analyzer specifications.
Code of Federal Regulations, 2010 CFR
2010-07-01
... flame ionization detector (HFID) analyzer. (b) Option. A non-heated flame ionization detector (FID) that... temperature oven housing the detector and sample-handling components. It shall maintain temperature with 2 °C of the set point. The detector, oven, and sample-handling components within the oven shall be...
40 CFR 86.317-79 - Hydrocarbon analyzer specifications.
Code of Federal Regulations, 2011 CFR
2011-07-01
... flame ionization detector (HFID) analyzer. (b) Option. A non-heated flame ionization detector (FID) that... temperature oven housing the detector and sample-handling components. It shall maintain temperature with 2 °C of the set point. The detector, oven, and sample-handling components within the oven shall be...
40 CFR 86.317-79 - Hydrocarbon analyzer specifications.
Code of Federal Regulations, 2013 CFR
2013-07-01
... flame ionization detector (HFID) analyzer. (b) Option. A non-heated flame ionization detector (FID) that... temperature oven housing the detector and sample-handling components. It shall maintain temperature with 2 °C of the set point. The detector, oven, and sample-handling components within the oven shall be...
Bonde, Robert K.; Garrett, Andrew; Belanger, Michael; Askin, Nesime; Tan, Luke; Wittnich, Carin
2012-01-01
Federal and state researchers have been involved in manatee (Trichechus manatus) biomedical health assessment programs for a couple of decades. These benchmark studies have provided a foundation for the development of consistent capture, handling, and processing techniques and protocols. Biologists have implemented training and encouraged multi-agency participation whenever possible to ensure reliable data acquisition, recording, sample collection, publication integrity, and meeting rigorous archival standards. Under a U.S. Fish and Wildlife Service wildlife research permit granted to the U.S. Geological Survey (USGS) Sirenia Project, federal biologists and collaborators are allowed to conduct research studies on wild and captive manatees detailing various aspects of their biology. Therefore, researchers with the project have been collaborating on numerous studies over the last several years. One extensive study, initiated in 2006 has focused on health and fitness of the winter manatee population located in Crystal River, Florida. During those health assessments, capture, handling, and work-up training has been afforded to many of the participants. That study has successfully captured and handled 123 manatees. The data gathered have provided baseline information on manatee health, reproductive status, and nutritional condition. This research initiative addresses concerns and priorities outlined in the Florida Manatee Recovery Plan. The assessment teams strive to continue this collaborative effort to help advance our understanding of health-related issues confronting manatees throughout their range and interlacing these findings with surrogate species concepts.
Rapid identification of bacteria with miniaturized pyrolysis/GC analysis
NASA Astrophysics Data System (ADS)
Morgan, Catherine H.; Mowry, Curtis; Manginell, Ronald P.; Frye-Mason, Gregory C.; Kottenstette, Richard J.; Lewis, Patrick
2001-02-01
Identification of bacteria and other biological moieties finds a broad range of applications in the environmental, biomedical, agricultural, industrial, and military arenas. Linking these applications are biological markers such as fatty acids, whose mass spectral profiles can be used to characterize biological samples and to distinguish bacteria at the gram-type, genera, and even species level. Common methods of sample analysis require sample preparation that is both lengthy and labor intensive, especially for whole cell bacteria. The background technique relied on here utilizes chemical derivatization of fatty acids to the more volatile fatty acid methyl esters (FAMEs), which can be separated on a gas chromatograph column or input directly into a mass spectrometer. More recent publications demonstrate improved sample preparation time with in situ derivatization of whole bacterial samples using pyrolysis at the inlet; although much faster than traditional techniques, these systems still rely on bench-top analytical equipment and individual sample preparation. Development of a miniaturized pyrolysis/GC instrument by this group is intended to realize the benefits of FAME identification of bacteria and other biological samples while further facilitating sample handling and instrument portability. The technologies being fabricated and tested have the potential of achieving pyrolysis and FAME separation on a very small scale, with rapid detection time (1-10 min from introduction to result), and with a modular sample inlet. Performance results and sensor characterization will be presented for the first phase of instrument development, encompassing the microfabricated pyrolysis and gas chromatograph elements.
Bonta, Maximilian; Frank, Johannes; Taibl, Stefanie; Fleig, Jürgen; Limbeck, Andreas
2018-02-13
Advanced materials such as complex metal oxides are used in a wide range of applications and have further promising perspectives in the form of thin films. The exact chemical composition essentially influences the electronic properties of these materials which makes correct assessment of their composition necessary. However, due to high chemical resistance and in the case of thin films low absolute analyte amounts, this procedure is in most cases not straightforward and extremely time-demanding. Commonly applied techniques either lack in ease of use (i.e., solution-based analysis with preceding sample dissolution), or adequately accurate quantification (i.e., solid sampling techniques). An analysis approach which combines the beneficial aspects of solution-based analysis as well as direct solid sampling is Laser Ablation of a Sample in Liquid (LASIL). In this work, it is shown that the analysis of major as well as minor sample constituents is possible using a novel online-LASIL setup, allowing sample analysis without manual sample handling after placing it in an ablation chamber. Strontium titanate (STO) thin layers with different compositions were analyzed in the course of this study. Precision of the newly developed online-LASIL method is comparable to conventional wet chemical approaches. With only about 15-20 min required for the analysis per sample, time demand is significantly reduced compared to often necessary fusion procedures lasting multiple hours. Copyright © 2017 Elsevier B.V. All rights reserved.
Airborne bacteria and fungi associated with waste-handling work.
Park, Donguk; Ryu, Seunghun; Kim, Shinbum; Byun, Hyaejeong; Yoon, Chungsik; Lee, Kyeongmin
2013-01-01
Municipal workers handling household waste are potentially exposed to a variety of toxic and pathogenic substances, in particular airborne bacteria, gram-negative bacteria (GNB), and fungi. However, relatively little is known about the conditions under which exposure is facilitated. This study assessed levels of airborne bacteria, GNB, and fungi, and examined these in relation to the type of waste-handling activity (collection, transfer, transport, and sorting at the waste preprocessing plant), as well as a variety of other environmental and occupational factors. Airborne microorganisms were sampled using an Andersen single-stage sampler equipped with agar plates containing the appropriate nutritional medium and then cultured to determine airborne levels. Samples were taken during collection, transfer, transport, and sorting of household waste. Multiple regression analysis was used to identify environmental and occupational factors that significantly affect airborne microorganism levels during waste-handling activities. The "type of waste-handling activity" was the only factor that significantly affected airborne levels of bacteria and GNB, accounting for 38% (P = 0.029) and 50% (P = 0.0002) of the variation observed in bacteria and GNB levels, respectively. In terms of fungi, the type of waste-handling activity (R2 = 0.76) and whether collection had also occurred on the day prior to sampling (P < 0.0001, R2 = 0.78) explained most of the observed variation. Given that the type of waste-handling activity was significantly correlated with levels of bacteria, GNB, and fungi, we suggest that various engineering, administrative, and regulatory measures should be considered to reduce the occupational exposure to airborne microorganisms in the waste-handling industry.
Nanomanipulation using near field photonics.
Erickson, David; Serey, Xavier; Chen, Yih-Fan; Mandal, Sudeep
2011-03-21
In this article we review the use of near-field photonics for trapping, transport and handling of nanomaterials. While the advantages of traditional optical tweezing are well known at the microscale, direct application of these techniques to the handling of nanoscale materials has proven difficult due to unfavourable scaling of the fundamental physics. Recently a number of research groups have demonstrated how the evanescent fields surrounding photonic structures like photonic waveguides, optical resonators, and plasmonic nanoparticles can be used to greatly enhance optical forces. Here, we introduce some of the most common implementations of these techniques, focusing on those which have relevance to microfluidic or optofluidic applications. Since the field is still relatively nascent, we spend much of the article laying out the fundamental and practical advantages that near field optical manipulation offers over both traditional optical tweezing and other particle handling techniques. In addition we highlight three application areas where these techniques namely could be of interest to the lab-on-a-chip community, namely: single molecule analysis, nanoassembly, and optical chromatography. This journal is © The Royal Society of Chemistry 2011
Effects of pretransport handling stress on physiological and behavioral response of ostriches.
Bejaei, M; Cheng, K M
2014-05-01
Ostrich (Struthio camelus) production is a relatively young industry and there has been little research on ostrich welfare during pretransport handling and the transportation process. A heavy body with a high center of gravity makes ostriches' handling and transportation problems different from other livestock. The main objective of this study was to investigate the effects of the pretransport holding time duration on ostrich behavior and physiological responses. A second objective was to identify and validate behavioral indicator(s) that could be used to identify stressed birds during pretransport handling. Prior to shipping, twenty-four 2.5-yr-old ostriches were moved into a holding pen. Birds were then individually restrained, hooded, and walked from the holding pen (approximately 12 min/bird) to a sampling pen (visually isolated from the holding pen) where they were weighed and a 10-mL blood sample obtained. A second blood sample was taken from each bird after a 1,100-km transportation. Blood samples were analyzed for concentrations of blood metabolites, enzymes, corticosterone, and white blood cell and differential counts. Behavioral responses and physical damages of ostriches were also recorded before and after transport. Results indicated that birds that spent longer time in the pretransport holding pen had higher pretransport plasma concentrations of aspartate aminotransferase, alanine aminotransferase, sodium, and packed cell volume. Immobile sitting behavior, observed in 5 out of the last 11 birds handled, was positively correlated with higher pretransport handling stress, higher posttransport aspartate aminotransferase, alanine aminotransferase, creatine phosphokinase, and glucose concentrations, and transport losses. Knowledge of pretransport handling impacts on ostrich stress and availability of behavioral indicators (e.g., immobile sitting response) could be used to improve handing processes, thereby decreasing potential weight loss, injury, and mortality.
Polur, Prasad D; Miller, Gerald E
2006-10-01
Computer speech recognition of individuals with dysarthria, such as cerebral palsy patients requires a robust technique that can handle conditions of very high variability and limited training data. In this study, application of a 10 state ergodic hidden Markov model (HMM)/artificial neural network (ANN) hybrid structure for a dysarthric speech (isolated word) recognition system, intended to act as an assistive tool, was investigated. A small size vocabulary spoken by three cerebral palsy subjects was chosen. The effect of such a structure on the recognition rate of the system was investigated by comparing it with an ergodic hidden Markov model as a control tool. This was done in order to determine if this modified technique contributed to enhanced recognition of dysarthric speech. The speech was sampled at 11 kHz. Mel frequency cepstral coefficients were extracted from them using 15 ms frames and served as training input to the hybrid model setup. The subsequent results demonstrated that the hybrid model structure was quite robust in its ability to handle the large variability and non-conformity of dysarthric speech. The level of variability in input dysarthric speech patterns sometimes limits the reliability of the system. However, its application as a rehabilitation/control tool to assist dysarthric motor impaired individuals holds sufficient promise.
Development and Applications of Portable Biosensors.
Srinivasan, Balaji; Tung, Steve
2015-08-01
The significance of microfluidics-based and microelectromechanical systems-based biosensors has been widely acknowledged, and many reviews have explored their potential applications in clinical diagnostics, personalized medicine, global health, drug discovery, food safety, and forensics. Because health care costs are increasing, there is an increasing need to remotely monitor the health condition of patients by point-of-care-testing. The demand for biosensors for detection of biological warfare agents has increased, and research is focused on ways of producing small portable devices that would allow fast, accurate, and on-site detection. In the past decade, the demand for rapid and accurate on-site detection of plant disease diagnosis has increased due to emerging pathogens with resistance to pesticides, increased human mobility, and regulations limiting the application of toxic chemicals to prevent spread of diseases. The portability of biosensors for on-site diagnosis is limited due to various issues, including sample preparation techniques, fluid-handling techniques, the limited lifetime of biological reagents, device packaging, integrating electronics for data collection/analysis, and the requirement of external accessories and power. Many microfluidic, electronic, and biological design strategies, such as handling liquids in biosensors without pumps/valves, the application of droplet-based microfluidics, paper-based microfluidic devices, and wireless networking capabilities for data transmission, are being explored. © 2015 Society for Laboratory Automation and Screening.
Szydzik, C; Gavela, A F; Herranz, S; Roccisano, J; Knoerzer, M; Thurgood, P; Khoshmanesh, K; Mitchell, A; Lechuga, L M
2017-08-08
A primary limitation preventing practical implementation of photonic biosensors within point-of-care platforms is their integration with fluidic automation subsystems. For most diagnostic applications, photonic biosensors require complex fluid handling protocols; this is especially prominent in the case of competitive immunoassays, commonly used for detection of low-concentration, low-molecular weight biomarkers. For this reason, complex automated microfluidic systems are needed to realise the full point-of-care potential of photonic biosensors. To fulfil this requirement, we propose an on-chip valve-based microfluidic automation module, capable of automating such complex fluid handling. This module is realised through application of a PDMS injection moulding fabrication technique, recently described in our previous work, which enables practical fabrication of normally closed pneumatically actuated elastomeric valves. In this work, these valves are configured to achieve multiplexed reagent addressing for an on-chip diaphragm pump, providing the sample and reagent processing capabilities required for automation of cyclic competitive immunoassays. Application of this technique simplifies fabrication and introduces the potential for mass production, bringing point-of-care integration of complex automated microfluidics into the realm of practicality. This module is integrated with a highly sensitive, label-free bimodal waveguide photonic biosensor, and is demonstrated in the context of a proof-of-concept biosensing assay, detecting the low-molecular weight antibiotic tetracycline.
Bedolla, Diana E; Mantuano, Andrea; Pickler, Arissa; Mota, Carla Lemos; Braz, Delson; Salata, Camila; Almeida, Carlos Eduardo; Birarda, Giovanni; Vaccari, Lisa; Barroso, Regina Cély; Gianoncelli, Alessandra
2018-05-01
Radiation damage is an important aspect to be considered when analysing biological samples with X-ray techniques as it can induce chemical and structural changes in the specimens. This work aims to provide new insights into the soft X-ray induced radiation damage of the complete sample, including not only the biological tissue itself but also the substrate and embedding medium, and the tissue fixation procedure. Sample preparation and handling involves an unavoidable interaction with the sample matrix and could play an important role in the radiation-damage mechanism. To understand the influence of sample preparation and handling on radiation damage, the effects of soft X-ray exposure at different doses on ultralene, paraffin and on paraffin-embedded rat tissues were studied using Fourier-transform infrared (FTIR) microspectroscopy and X-ray microscopy. Tissues were preserved with three different commonly used fixatives: formalin, glutaraldehyde and Karnovsky. FTIR results showed that ultralene and paraffin undergo a dose-dependent degradation of their vibrational profiles, consistent with radiation-induced oxidative damage. In addition, formalin fixative has been shown to improve the preservation of the secondary structure of proteins in tissues compared with both glutaraldehyde and Karnovsky fixation. However, conclusive considerations cannot be drawn on the optimal fixation protocol because of the interference introduced by both substrate and embedding medium in the spectral regions specific to tissue lipids, nucleic acids and carbohydrates. Notably, despite the detected alterations affecting the chemical architecture of the sample as a whole, composed of tissue, substrate and embedding medium, the structural morphology of the tissues at the micrometre scale is essentially preserved even at the highest exposure dose.
Hanson, Jennifer A; Hughes, Susan M; Liu, Pei
2015-12-01
Unsafe food handling behaviors are common among consumers, and, given the venue, individuals attending a tailgating event may be at risk for foodborne illness. The objective of this study was to measure the association between Health Belief Model variables and self-reported usual food handling behaviors in a convenience sample of men and women at a tailgate event. Participants (n = 128) completed validated subscales for self-reported food handling behaviors (i.e., cross-contamination, sanitation), perceived threat of foodborne illness (i.e., perceived severity, perceived susceptibility), and safe food handling cues to action (i.e., media cues, educational cues). Perceived severity of foodborne illness was associated with safer behaviors related to sanitation (r = 0.40; P < 0.001) and cross-contamination (r = 0.33; P = 0.001). Perceived severity of foodborne illness was also associated with exposure to safe food handling media cues (r = 0.20; P = 0.027) but not with safe food handling educational cues. A large proportion of participants reported that they never or seldom (i) read newspaper or magazine articles about foodborne illness (65.6%); (ii) read brochures about safe ways to handle food (61.7%); (iii) see store displays that explain ways to handle food (51.6%); or (iv) read the "safe handling instructions" on packages of raw meat and poultry (46.9%). Perceived severity of foodborne illness was positively related to both dimensions of safe food handling as well as with safe food handling media cues. Except for the weak correlation between media cues and perceived severity, the relationships between safe food handling cues and perceived threat, as well as between safe food handling cues and behaviors, were nonsignificant. This finding may be due, in part, to the participants' overall low exposure to safe food handling cues. The overall results of this study reinforce the postulate that perceived severity of foodborne illness may influence food handling behaviors.
Practical Tips for the Safe Handling of Micro-organisms in Schools
ERIC Educational Resources Information Center
Holt, G.
1974-01-01
Outlines safe laboratory procedures for the handling of micro-organisms including aseptic technique, manipulation of cultures, and treatment of contaminated equipment. Identifies the principal hazard as the microbial aerosol, explains its possible effects, and describes the appropriate precautions. (GS)
Lee, Sang Min; Chang, Yoon-Seok; Kim, Cheol-Woo; Kim, Tae-Bum; Kim, Sang-Heon; Kwon, Yong-Eun; Lee, Jong-Myung; Lee, Soo-Keol; Jeong, Jae-Won; Park, Jung-Won; Cho, Sang-Heon; Moon, Hee-Bom
2011-01-01
Purpose The objective of this study was to evaluate skills in handling inhalers and factors associated with these skills among patients with asthma who had undergone treatment at special asthma and allergy clinics in Korea. Methods We enrolled 78 subjects who used Turbuhaler and 145 who used Diskus for asthma control at special clinics in 10 university hospitals and visually assessed their skills in handling these inhalers. We also evaluated skills in 137 subjects who had used pressurized metered-dose inhalers (pMDIs) for symptom relief. Age, sex, duration of asthma and inhaler use, smoking status, monthly income, highest grade completed in school and previous instruction for handling inhalers were also measured to evaluate their association with overall inhaler skills. Results Performance grade was inadequate for 12.8% of participants using Turbuhaler, 6.2% for Diskus, and 23.4% for pMDIs. The success rates for each step in handling the inhalers were relatively high except for the "exhale slowly to residual volume" step, in which success rates ranged from 24.2% to 28.5%. Older age, male sex, lower educational grade, and absence of previous instruction for handling inhalers were associated with inadequate inhaler technique in univariate analysis; however, only older age and absence of previous instruction remained significant independent risk factors in multivariate analysis. Conclusions Among Korean asthmatic patients in special asthma and allergy clinics, skills in handling their inhalers were mostly excellent; meanwhile, older age and absence of previous instruction for handling inhalers were associated with inadequate techniques. PMID:21217925
Thin layer chromatography residue applicator sampler
Nunes, Peter J [Danville, CA; Kelly, Fredrick R [Modesto, CA; Haas, Jeffrey S [San Ramon, CA; Andresen, Brian D [Livermore, CA
2007-07-24
A thin layer chromatograph residue applicator sampler. The residue applicator sampler provides for rapid analysis of samples containing high explosives, chemical warfare, and other analyses of interest under field conditions. This satisfied the need for a field-deployable, small, hand-held, all-in-one device for efficient sampling, sample dissolution, and sample application to an analytical technique. The residue applicator sampler includes a sampling sponge that is resistant to most chemicals and is fastened via a plastic handle in a hermetically sealed tube containing a known amount of solvent. Upon use, the wetted sponge is removed from the sealed tube and used as a swiping device across an environmental sample. The sponge is then replaced in the hermetically sealed tube where the sample remains contained and dissolved in the solvent. A small pipette tip is removably contained in the hermetically sealed tube. The sponge is removed and placed into the pipette tip where a squeezing-out of the dissolved sample from the sponge into the pipette tip results in a droplet captured in a vial for later instrumental analysis, or applied directly to a thin layer chromatography plate for immediate analysis.
Szulc, P; Naylor, K; Hoyle, N R; Eastell, R; Leary, E T
2017-09-01
The National Bone Health Alliance (NBHA) recommends standardized sample handling and patient preparation for C-terminal telopeptide of type I collagen (CTX-I) and N-terminal propeptide of type I procollagen (PINP) measurements to reduce pre-analytical variability. Controllable and uncontrollable patient-related factors are reviewed to facilitate interpretation and minimize pre-analytical variability. The IOF and the International Federation of Clinical Chemistry (IFCC) Bone Marker Standards Working Group have identified PINP and CTX-I in blood to be the reference markers of bone turnover for the fracture risk prediction and monitoring of osteoporosis treatment. Although used in clinical research for many years, bone turnover markers (BTM) have not been widely adopted in clinical practice primarily due to their poor within-subject and between-lab reproducibility. The NBHA Bone Turnover Marker Project team aim to reduce pre-analytical variability of CTX-I and PINP measurements through standardized sample handling and patient preparation. Recommendations for sample handling and patient preparations were made based on review of available publications and pragmatic considerations to reduce pre-analytical variability. Controllable and un-controllable patient-related factors were reviewed to facilitate interpretation and sample collection. Samples for CTX-I must be collected consistently in the morning hours in the fasted state. EDTA plasma is preferred for CTX-I for its greater sample stability. Sample collection conditions for PINP are less critical as PINP has minimal circadian variability and is not affected by food intake. Sample stability limits should be observed. The uncontrollable aspects (age, sex, pregnancy, immobility, recent fracture, co-morbidities, anti-osteoporotic drugs, other medications) should be considered in BTM interpretation. Adopting standardized sample handling and patient preparation procedures will significantly reduce controllable pre-analytical variability. The successful adoption of such recommendations necessitates the close collaboration of various stakeholders at the global stage, including the laboratories, the medical community, the reagent manufacturers and the regulatory agencies.
Rao, Vatturi Venkata Satya Prabhakar; Manthri, Ranadheer; Hemalatha, Pottumuthu; Kumar, Vuyyuru Navin; Azhar, Mohammad
2016-01-01
Hot lab dispensing of large doses of 18 fluorine fluorodeoxyglucose in master vials supplied from the cyclotrons requires high degrees of skill to handle high doses. Presently practiced conventional method of fractionating from the inverted tiltable vial pig mounted on a metal frame has its own limitations such as increasing isotope handling times and exposure to the technologist. Innovative technique devised markedly improves the fractionating efficiency along with speed, precision, and reduced dose exposure. PMID:27095872
LACIE data-handling techniques
NASA Technical Reports Server (NTRS)
Waits, G. H. (Principal Investigator)
1979-01-01
Techniques implemented to facilitate processing of LANDSAT multispectral data between 1975 and 1978 are described. The data that were handled during the large area crop inventory experiment and the storage mechanisms used for the various types of data are defined. The overall data flow, from the placing of the LANDSAT orders through the actual analysis of the data set, is discussed. An overview is provided of the status and tracking system that was developed and of the data base maintenance and operational task. The archiving of the LACIE data is explained.
Dynamic stability and handling qualities tests on a highly augmented, statically unstable airplane
NASA Technical Reports Server (NTRS)
Gera, Joseph; Bosworth, John T.
1987-01-01
This paper describes some novel flight tests and analysis techniques in the flight dynamics and handling qualities area. These techniques were utilized during the initial flight envelope clearance of the X-29A aircraft and were largely responsible for the completion of the flight controls clearance program without any incidents or significant delays. The resulting open-loop and closed-loop frequency responses and the time history comparison using flight and linear simulation data are discussed.
Automatic liquid handling for life science: a critical review of the current state of the art.
Kong, Fanwei; Yuan, Liang; Zheng, Yuan F; Chen, Weidong
2012-06-01
Liquid handling plays a pivotal role in life science laboratories. In experiments such as gene sequencing, protein crystallization, antibody testing, and drug screening, liquid biosamples frequently must be transferred between containers of varying sizes and/or dispensed onto substrates of varying types. The sample volumes are usually small, at the micro- or nanoliter level, and the number of transferred samples can be huge when investigating large-scope combinatorial conditions. Under these conditions, liquid handling by hand is tedious, time-consuming, and impractical. Consequently, there is a strong demand for automated liquid-handling methods such as sensor-integrated robotic systems. In this article, we survey the current state of the art in automatic liquid handling, including technologies developed by both industry and research institutions. We focus on methods for dealing with small volumes at high throughput and point out challenges for future advancements.
Olamoyegun, M A; Oloyede, T; Adewoye, O G; Abdulkarim, S O; Adeleke, A A
2016-01-01
Self-monitoring of blood glucose (SMBG) is an important component of management for diabetes mellitus (DM), especially in T1DM and T2DM patients who are on insulin therapy. Adequate blood glucose monitoring and prompt intervention are necessary to prevent blood glucose (BG) fluctuation and delay long-term diabetes complications. People with DM are advised to clean their hands before SMBG to remove any dirt or food residue that might affect the reading. The study tested the hypothesis that falsely elevated BG levels from fingertip occur after peeling or handling fruits in an unwashed hand. Fifty apparently healthy nondiabetes volunteers were enrolled. Capillary BG samples were collected from the fingertips after peeling or handling apple, orange, banana, watermelon, and pawpaw, followed by no hand washing for 1 h, cleaning the fingertip with alcohol swab once, five times, and washing hand thoroughly with tap water and drying. These samples were then analyzed with two different glucose meters. The mean BG values, measured from fingertip blood samples after peeling, and handling any of the fruits followed by no hand washing were significantly high, even after cleaning fingertip with a swab of alcohol once. However, there were no significant difference in BG levels measured after peeling and handling fruits followed by hand washing and the level of BG before peeling and handling fruits. Handling of peeled fruits with no hand washing with tap water is associated with overestimation of capillary BG (Pseudohyperglycemia) monitored with glucose meters.
PVA with nopal dye as holographic recording material
NASA Astrophysics Data System (ADS)
Toxqui-López, S.; Olivares-Pérez, A.; Fuentes-Tapia, I.; Pinto-Iguanero, B.
2011-09-01
Cactus nopal dye is introduced into a polyvinyl alcohol matrix achieving a like brown appearance thick film, such that they can be used as a recording medium. This dye material provides excellent property as photosensitizer, i.e., easy handling, low cost and can be used in real time holographic recording applications. The experimental results show the diffraction efficiencies obtained by recording grating patterns induced by a He-Cd laser (442nm). For the samples, a thick film of polyvinyl alcohol and dye from cactus nopal was deposited by the gravity technique on a glass substrate. This mixture dries to form a photosensitive emulsion.
Two-way cable television project
NASA Astrophysics Data System (ADS)
Wilkens, H.; Guenther, P.; Kiel, F.; Kraus, F.; Mahnkopf, P.; Schnee, R.
1982-02-01
The market demand for a multiuser computer system with interactive services was studied. Mean system work load at peak use hours was estimated and the complexity of dialog with a central computer was determined. Man machine communication by broadband cable television transmission, using digital techniques, was assumed. The end to end system is described. It is user friendly, able to handle 10,000 subscribers, and provides color television display. The central computer system architecture with remote audiovisual terminals is depicted and software is explained. Signal transmission requirements are dealt with. International availability of the test system, including sample programs, is indicated.
Topography Modeling in Atmospheric Flows Using the Immersed Boundary Method
NASA Technical Reports Server (NTRS)
Ackerman, A. S.; Senocak, I.; Mansour, N. N.; Stevens, D. E.
2004-01-01
Numerical simulation of flow over complex geometry needs accurate and efficient computational methods. Different techniques are available to handle complex geometry. The unstructured grid and multi-block body-fitted grid techniques have been widely adopted for complex geometry in engineering applications. In atmospheric applications, terrain fitted single grid techniques have found common use. Although these are very effective techniques, their implementation, coupling with the flow algorithm, and efficient parallelization of the complete method are more involved than a Cartesian grid method. The grid generation can be tedious and one needs to pay special attention in numerics to handle skewed cells for conservation purposes. Researchers have long sought for alternative methods to ease the effort involved in simulating flow over complex geometry.
A technique for the assessment of fighter aircraft precision controllability
NASA Technical Reports Server (NTRS)
Sisk, T. R.
1978-01-01
Today's emerging fighter aircraft are maneuvering as well at normal accelerations of 7 to 8 g's as their predecessors did at 4 to 5 g's. This improved maneuvering capability has significantly expanded their operating envelope and made the task of evaluating handling qualities more difficult. This paper describes a technique for assessing the precision controllability of highly maneuverable aircraft, a technique that was developed to evaluate the effects of buffet intensity on gunsight tracking capability and found to be a useful tool for the general assessment of fighter aircraft handling qualities. It has also demonstrated its usefulness for evaluating configuration and advanced flight control system refinements. This technique is believed to have application to future aircraft dynamics and pilot-vehicle interface studies.
An Investigation of Large Aircraft Handling Qualities
NASA Astrophysics Data System (ADS)
Joyce, Richard D.
An analytical technique for investigating transport aircraft handling qualities is exercised in a study using models of two such vehicles, a Boeing 747 and Lockheed C-5A. Two flight conditions are employed for climb and directional tasks, and a third included for a flare task. The analysis technique is based upon a "structural model" of the human pilot developed by Hess. The associated analysis procedure has been discussed previously in the literature, but centered almost exclusively on the characteristics of high-performance fighter aircraft. The handling qualities rating level (HQRL) and pilot induced oscillation tendencies rating level (PIORL) are predicted for nominal configurations of the aircraft and for "damaged" configurations where actuator rate limits are introduced as nonlinearites. It is demonstrated that the analysis can accommodate nonlinear pilot/vehicle behavior and do so in the context of specific flight tasks, yielding estimates of handling qualities, pilot-induced oscillation tendencies and upper limits of task performance. A brief human-in-the-loop tracking study was performed to provide a limited validation of the pilot model employed.
Results Of Automating A Photolithography Cell In A Clean Tunnel
NASA Astrophysics Data System (ADS)
June, David H.
1987-01-01
A prototype automated photobay was installed in an existing fab area utilizing flexible material handling techniques within a clean tunnel. The project objective was to prove design concepts of automated cassette-to-cassette handling within a clean tunnel that isolated operators from the wafers being processed. Material handling was by monorail track transport system to feed cassettes to pick and place robots. The robots loaded and unloaded cassettes of wafers to each of the various pieces of process equipment. The material handling algorithms, recipe downloading and statistical process control functions were all performed by custom software on the photobay cell controller.
Exploring the Connection Between Sampling Problems in Bayesian Inference and Statistical Mechanics
NASA Technical Reports Server (NTRS)
Pohorille, Andrew
2006-01-01
The Bayesian and statistical mechanical communities often share the same objective in their work - estimating and integrating probability distribution functions (pdfs) describing stochastic systems, models or processes. Frequently, these pdfs are complex functions of random variables exhibiting multiple, well separated local minima. Conventional strategies for sampling such pdfs are inefficient, sometimes leading to an apparent non-ergodic behavior. Several recently developed techniques for handling this problem have been successfully applied in statistical mechanics. In the multicanonical and Wang-Landau Monte Carlo (MC) methods, the correct pdfs are recovered from uniform sampling of the parameter space by iteratively establishing proper weighting factors connecting these distributions. Trivial generalizations allow for sampling from any chosen pdf. The closely related transition matrix method relies on estimating transition probabilities between different states. All these methods proved to generate estimates of pdfs with high statistical accuracy. In another MC technique, parallel tempering, several random walks, each corresponding to a different value of a parameter (e.g. "temperature"), are generated and occasionally exchanged using the Metropolis criterion. This method can be considered as a statistically correct version of simulated annealing. An alternative approach is to represent the set of independent variables as a Hamiltonian system. Considerab!e progress has been made in understanding how to ensure that the system obeys the equipartition theorem or, equivalently, that coupling between the variables is correctly described. Then a host of techniques developed for dynamical systems can be used. Among them, probably the most powerful is the Adaptive Biasing Force method, in which thermodynamic integration and biased sampling are combined to yield very efficient estimates of pdfs. The third class of methods deals with transitions between states described by rate constants. These problems are isomorphic with chemical kinetics problems. Recently, several efficient techniques for this purpose have been developed based on the approach originally proposed by Gillespie. Although the utility of the techniques mentioned above for Bayesian problems has not been determined, further research along these lines is warranted
Detection of Papaverine for the Possible Identification of Illicit Opium Cultivation.
Mirsafavi, Rustin Y; Lai, Kristine; Kline, Neal D; Fountain, Augustus W; Meinhart, Carl D; Moskovits, Martin
2017-02-07
Papaverine is a non-narcotic alkaloid found endemically and uniquely in the latex of the opium poppy. It is normally refined out of the opioids that the latex is typically collected for, hence its presence in a sample is strong prima facie evidence that the carrier from whom the sample was collected is implicated in the mass cultivation of poppies or the collection and handling of their latex. We describe an analysis technique combining surface-enhanced Raman spectroscopy (SERS) with microfluidics for detecting papaverine at low concentrations and show that its SERS spectrum has unique spectroscopic features that allows its detection at low concentrations among typical opioids. The analysis requires approximately 2.5 min from sample loading to results, which is compatible with field use. The weak acid properties of papaverine hydrochloride were investigated, and Raman bands belonging to the protonated and unprotonated forms of the isoquinoline ring of papaverine were identified.
Robotic Sample Manipulator for Handling Astromaterials Inside the Geolab Microgravity Glovebox
NASA Technical Reports Server (NTRS)
Bell, Mary S.; Calaway, M. J.; Evans, C. A.; Li,Z.; Tong, S.; Zhong, Y.; Dahiwala, R.; Wang, L.; Porter, F.
2013-01-01
Future human and robotic sample return missions will require isolation containment systems with strict protocols and procedures for reducing inorganic and organic contamination. Robotic handling and manipulation of astromaterials may be required for preliminary examination inside such an isolation containment system. In addition, examination of astromaterials in microgravity will require constant contact to secure samples during manipulation. The National Space Grant Foundation exploration habitat (XHab) academic innovative challenge 2012 administered through the NASA advanced exploration systems (AES) deep space habitat (DSH) project awarded funding to the University of Bridgeport team to develop an engineering design for tools to facilitate holding and handling geological samples for analysis in a microgravity glovebox environment. The Bridgeport XHab team developed a robotic arm system with a three-finger gripper that could manipulate geologic samples within the existing GeoLab glovebox integrated into NASA's DSH called the GeoLab Robotic Sample Manipulator (see fig. 1 and 2). This hardware was deployed and tested during the 2012 DSH mission operations tests [1].
Flight test experience with high-alpha control system techniques on the F-14 airplane
NASA Technical Reports Server (NTRS)
Gera, J.; Wilson, R. J.; Enevoldson, E. K.; Nguyen, L. T.
1981-01-01
Improved handling qualities of fighter aircraft at high angles of attack can be provided by various stability and control augmentation techniques. NASA and the U.S. Navy are conducting a joint flight demonstration of these techniques on an F-14 airplane. This paper reports on the flight test experience with a newly designed lateral-directional control system which suppresses such high angle of attack handling qualities problems as roll reversal, wing rock, and directional divergence while simultaneously improving departure/spin resistance. The technique of integrating a piloted simulation into the flight program was used extensively in this program. This technique had not been applied previously to high angle of attack testing and required the development of a valid model to simulate the test airplane at extremely high angles of attack.
ENGINEERING BULLETIN: CONTROL OF AIR EMISSIONS FROM MATERIALS HANDLING DURING REMEDIATION
This bulletin presents an overview discussion on the importance of and methods for controlling emissions into the air from materials handling processes at Superfund or other hazardous waste sites. It also describes several techniques used for dust and vapor suppress ion that have...
Sorge, U S; Cherry, C; Bender, J B
2014-07-01
Proper cattle-handling techniques (stockmanship) are important to ensure calm animals and a safe work environment for dairy workers on farm. The objectives of this study were to (1) assess Minnesota dairy herd owners' attitudes toward stockmanship, its perceived importance for cow comfort and worker health, and the establishment of calm cattle movement; and (2) identify current resources and methods of stockmanship training on Minnesota dairy farms. A stratified-random sample of Minnesota dairy farmers were contacted via mail to participate in a 28-question survey. One hundred eight bovine dairy producers participated. Most commonly, respondents learned their cattle handling skills from family members (42.6%) and 29.9% of producers had participated in previous stockmanship training. Producers thought that the skill of the human handler was the most important factor in establishing good cattle flow. Cattle-handling techniques was the third most common topic for new-employee orientation after training in milking parlor protocols and milking parlor disinfection. Time limitations and language barrier were considered serious challenges for worker training. Work-related injuries were responsible for lost work days in the previous year in 13.3% of dairy herds and 73.3% of those injuries occurred while working with cattle. Producers perceived that cattle-related injuries were predominantly the handler's fault: either because of not paying enough attention to the animal or due to poor cattle handling skills. Facility design was considered the least important for the occurrence of worker injuries. Although no causal inference can be made, herds that had workers who had previously participated in stockmanship training had a 810 ± 378 kg (mean ± standard error of the mean) higher rolling herd average than those that did not, even after adjusting for herd size and bulk tank somatic cell count. However, 50% of respondents were not interested in attending future stockmanship training sessions. In conclusion, cattle handling skills are considered important by Minnesota dairy producers to ensure worker safety and cow flow. Limited availability of time, language barrier, and a perceived lack of training materials were considered challenges during the training of workers on farms. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
A powerful and flexible approach to the analysis of RNA sequence count data.
Zhou, Yi-Hui; Xia, Kai; Wright, Fred A
2011-10-01
A number of penalization and shrinkage approaches have been proposed for the analysis of microarray gene expression data. Similar techniques are now routinely applied to RNA sequence transcriptional count data, although the value of such shrinkage has not been conclusively established. If penalization is desired, the explicit modeling of mean-variance relationships provides a flexible testing regimen that 'borrows' information across genes, while easily incorporating design effects and additional covariates. We describe BBSeq, which incorporates two approaches: (i) a simple beta-binomial generalized linear model, which has not been extensively tested for RNA-Seq data and (ii) an extension of an expression mean-variance modeling approach to RNA-Seq data, involving modeling of the overdispersion as a function of the mean. Our approaches are flexible, allowing for general handling of discrete experimental factors and continuous covariates. We report comparisons with other alternate methods to handle RNA-Seq data. Although penalized methods have advantages for very small sample sizes, the beta-binomial generalized linear model, combined with simple outlier detection and testing approaches, appears to have favorable characteristics in power and flexibility. An R package containing examples and sample datasets is available at http://www.bios.unc.edu/research/genomic_software/BBSeq yzhou@bios.unc.edu; fwright@bios.unc.edu Supplementary data are available at Bioinformatics online.
Neutron/gamma pulse shape discrimination (PSD) in plastic scintillators with digital PSD electronics
NASA Astrophysics Data System (ADS)
Hutcheson, Anthony L.; Simonson, Duane L.; Christophersen, Marc; Phlips, Bernard F.; Charipar, Nicholas A.; Piqué, Alberto
2013-05-01
Pulse shape discrimination (PSD) is a common method to distinguish between pulses produced by gamma rays and neutrons in scintillator detectors. This technique takes advantage of the property of many scintillators that excitations by recoil protons and electrons produce pulses with different characteristic shapes. Unfortunately, many scintillating materials with good PSD properties have other, undesirable properties such as flammability, toxicity, low availability, high cost, and/or limited size. In contrast, plastic scintillator detectors are relatively low-cost, and easily handled and mass-produced. Recent studies have demonstrated efficient PSD in plastic scintillators using a high concentration of fluorescent dyes. To further investigate the PSD properties of such systems, mixed plastic scintillator samples were produced and tested. The addition of up to 30 wt. % diphenyloxazole (DPO) and other chromophores in polyvinyltoluene (PVT) results in efficient detection with commercial detectors. These plastic scintillators are produced in large diameters up to 4 inches by melt blending directly in a container suitable for in-line detector use. This allows recycling and reuse of materials while varying the compositions. This strategy also avoids additional sample handling and polishing steps required when using removable molds. In this presentation, results will be presented for different mixed-plastic compositions and compared with known scintillating materials
NASA Astrophysics Data System (ADS)
Kitsara, Maria; Cirera, Josep Maria; Aller-Pellitero, Miguel; Sabaté, Neus; Punter, Jaume; Colomer-Farrarons, Jordi; Miribel-Català, Pere; del Campo, F. Javier
2015-06-01
The development of a low-cost multiparametric platform for enzymatic electrochemical biosensing that can be integrated in a disposable, energy autonomous analytical device is the target of the current work. We propose a technology to fabricate nano-electrodes and ultimately biosensors on flexible polymeric-based substrates (cyclo olefin polymer, and polyimide) using standard microfabrication (step and repeat lithography and lift-off) and rapid prototyping techniques (blade cutting). Our target is towards the fabrication of a miniaturized prototype that can work with small sample volumes in the range of 5-10μL without the need for external pumps for sample loading and handling. This device can be used for the simultaneous detection of metabolites such as glucose, cholesterol and triglycerides for the early diagnosis of diabetes.
McGee, M
1994-07-01
This article offers insights into the relationship of llama owners to their animals and the role of veterinarians as part of the animal care team. The effect of human behavior and handling techniques on llama behavior and marketability are discussed. Progressive ideas for nonforceful llama handling equipment, procedures, and training ideas are outlined in detail. Included are specific training plans for routine herd management chores such as injections and toenail trimming. This article is useful for both veterinarians and llama owners.
Influence of Conflict Resolution Training on Conflict Handling Styles of College Students
ERIC Educational Resources Information Center
Waithaka, Abel Gitimu; Moore-Austin, Shante'; Gitimu, Priscilla N.
2015-01-01
The purpose of this study was to investigate the influence of conflict resolution skills training on conflict handling styles, and conflict orientation of college students. Conflict handling styles was measured by the Thomas-Kilmann MODE instrument, while Conflict orientation was measured by conflict orientation survey instrument. A sample of 135…
Refrigeration is not necessary for measurement of uric acid in patients treated with rasburicase.
Lindeman, Neal I; Melanson, Stacy E F; McDonnell, Anne; DeAngelo, Daniel J; Jarolim, Petr
2013-05-01
Rasburicase, used for hyperuricemia of tumor lysis syndrome, retains activity at room temperature (RT) in in vitro studies. Cold-temperature handling is recommended for uric acid measurements in patients receiving rasburicase: collection in prechilled tubes, transportation on ice, and 4°C centrifugation. We performed a prospective study of these requirements. A total of 65 pairs of blood samples were collected from 34 patients, 12-24 h after receiving rasburicase. The effect of temperature on uric acid concentration was tested on paired samples handled either at RT or when cold: centrifugation (18 sample pairs), collection tube (14 pairs), transportation (24 pairs), and nine pairs were retested after 1 h at RT. No significant temperature effect was seen on the uric acid measurements for any of the cold-handling steps: proportional, absolute biases were -1.4%, -0.06 mg/dL (centrifugation), -1.5%, +0.02 mg/dL (tube temperature), and -2.2%, -0.01 mg/dL (transportation). A 20% negative bias was seen in samples retested after 1 h at RT. Cold handling (prechilled tubes, iced transportation, 4°C centrifugation) was equivalent to RT for immediate measurement. An additional 1 h delay at RT led to a 20% decrease in uric acid. The cold handling measures required by the manufacturer are not necessary for uric acid testing of patients receiving rasburicase treatment, if testing is performed without delay.
New Measurements of the Particle Size Distribution of Apollo 11 Lunar Soil 10084
NASA Technical Reports Server (NTRS)
McKay, D.S.; Cooper, B.L.; Riofrio, L.M.
2009-01-01
We have initiated a major new program to determine the grain size distribution of nearly all lunar soils collected in the Apollo program. Following the return of Apollo soil and core samples, a number of investigators including our own group performed grain size distribution studies and published the results [1-11]. Nearly all of these studies were done by sieving the samples, usually with a working fluid such as Freon(TradeMark) or water. We have measured the particle size distribution of lunar soil 10084,2005 in water, using a Microtrac(TradeMark) laser diffraction instrument. Details of our own sieving technique and protocol (also used in [11]). are given in [4]. While sieving usually produces accurate and reproducible results, it has disadvantages. It is very labor intensive and requires hours to days to perform properly. Even using automated sieve shaking devices, four or five days may be needed to sieve each sample, although multiple sieve stacks increases productivity. Second, sieving is subject to loss of grains through handling and weighing operations, and these losses are concentrated in the finest grain sizes. Loss from handling becomes a more acute problem when smaller amounts of material are used. While we were able to quantitatively sieve into 6 or 8 size fractions using starting soil masses as low as 50mg, attrition and handling problems limit the practicality of sieving smaller amounts. Third, sieving below 10 or 20microns is not practical because of the problems of grain loss, and smaller grains sticking to coarser grains. Sieving is completely impractical below about 5- 10microns. Consequently, sieving gives no information on the size distribution below approx.10 microns which includes the important submicrometer and nanoparticle size ranges. Finally, sieving creates a limited number of size bins and may therefore miss fine structure of the distribution which would be revealed by other methods that produce many smaller size bins.
Facility Concepts for Mars Returned Sample Handling
NASA Technical Reports Server (NTRS)
Cohen, Marc M.; Briggs, Geoff (Technical Monitor)
2001-01-01
Samples returned from Mars must be held in quarantine until their biological safety has been determined. A significant challenge, unique to NASA's needs, is how to contain the samples (to protect the blaspheme) while simultaneously protecting their pristine nature. This paper presents a comparative analysis of several quarantine facility concepts for handling and analyzing these samples. The considerations in this design analysis include: modes of manipulation; capability for destructive as well as non-destructive testing; avoidance of cross-contamination; linear versus recursive processing; and sample storage and retrieval within a closed system. The ability to rigorously contain biologically hazardous materials has been amply demonstrated by facilities that meet the specifications of the Center for Disease Control Biosafety Level 4. The newly defined Planetary Protection Level Alpha must provide comparable containment while assuring that the samples remain pristine; the latter requirement is based on the need to avoid compromising science analyses by instrumentation of the highest possible sensitivity (among other things this will assure that there is no false positive detection of organisms or organic molecules - a situation that would delay or prevent the release of the samples from quarantine). Protection of the samples against contamination by terrestrial organisms and organic molecules makes a considerable impact upon the sample handling facility. The use of glove boxes appears to be impractical because of their tendency to leak and to surges. As a result, a returned sample quarantine facility must consider the use of automation and remote manipulation to carry out the various functions of sample handling and transfer within the system. The problem of maintaining sensitive and bulky instrumentation under the constraints of simultaneous sample containment and contamination protection also places demands on the architectural configuration of the facility that houses it.
Sample Acquisition and Handling System from a Remote Platform
NASA Technical Reports Server (NTRS)
Badescu, Mircea; Sherrit, Stewart; Jones, Jack A.
2011-01-01
A system has been developed to acquire and handle samples from a suspended remote platform. The system includes a penetrator, a penetrator deployment mechanism, and a sample handler. A gravity-driven harpoon sampler was used for the system, but other solutions can be used to supply the penetration energy, such as pyrotechnic, pressurized gas, or springs. The deployment mechanism includes a line that is attached to the penetrator, a spool for reeling in the line, and a line engagement control mechanism. The penetrator has removable tips that can collect liquid, ice, or solid samples. The handling mechanism consists of a carousel that can store a series of identical or different tips, assist in penetrator reconfiguration for multiple sample acquisition, and deliver the sample to a series of instruments for analysis. The carousel sample handling system was combined with a brassboard reeling mechanism and a penetrator with removable tips. It can attach the removable tip to the penetrator, release and retrieve the penetrator, remove the tip, and present it to multiple instrument stations. The penetrator can be remotely deployed from an aerobot, penetrate and collect the sample, and be retrieved with the sample to the aerobot. The penetrator with removable tips includes sample interrogation windows and a sample retainment spring for unconsolidated samples. The line engagement motor can be used to control the penetrator release and reeling engagement, and to evenly distribute the line on the spool by rocking between left and right ends of the spool. When the arm with the guiding ring is aligned with the spool axis, the line is free to unwind from the spool without rotating the spool. When the arm is perpendicular to the spool axis, the line can move only if the spool rotates.
Horká, Marie; Horký, Jaroslav; Kubesová, Anna; Zapletalová, Eva; Slais, Karel
2011-07-01
Trace analysis of microorganisms in real biological samples needs very sensitive methods for their detection. Most procedures for detecting and quantifying pathogens require a sample preparation step including concentrating microorganisms from large sample volumes with high and reproducible efficiency. Electromigration techniques have great potential to include the preconcentration, separation, and detection of whole cells and therefore they can rapidly indicate the presence of pathogens. The preconcentration and separation of microorganisms from real suspensions utilising a combination of filtration and capillary isoelectric focusing was developed and the possibility for its application to real samples was verified. For our experiments, spores of Monilinia species and of Penicillium expansum were selected as model bioparticles, as they cause major losses in agrosystems. The isoelectric points of the spores of M. laxa, M. fructigena, M. fruticola, and P. expansum were determined and the method was verified using real samples taken directly from infected apples. The coupling of a filtration cartridge with a separation capillary can improve the detection limit of isoelectric focusing with UV detection by at least 4 orders of magnitude. Spores of M. fructigena and of M. laxa in numbers of hundreds of particles per milliliter were detected on a visually noninfected apple surface which was cross-contaminated during handling and storage. The efficiency of preconcentration and a preliminary identification was verified by the phenotyping technique after cultivation of the spores sampled from the apple surface.
NASA Technical Reports Server (NTRS)
Feather, J. B.; Joshi, D. S.
1981-01-01
Handling qualities of the unaugmented advanced supersonic transport (AST) are deficient in the low-speed, landing approach regime. Consequently, improvement in handling with active control augmentation systems has been achieved using implicit model-following techniques. Extensive fixed-based simulator evaluations were used to validate these systems prior to tests with full motion and visual capabilities on a six-axis motion-base simulator (MBS). These tests compared the handling qualities of the unaugmented AST with several augmented configurations to ascertain the effectiveness of these systems. Cooper-Harper ratings, tracking errors, and control activity data from the MBS tests have been analyzed statistically. The results show the fully augmented AST handling qualities have been improved to an acceptable level.
The detection of blood on dental surgery surfaces and equipment following dental hygiene treatment.
McColl, E; Bagg, J; Winning, S
1994-01-22
The Kastle-Meyer technique, a forensic test for blood, has been employed to assess the frequency and potential routes of contamination by blood between patients, staff and equipment during routine dental hygiene treatment. Fifty treatment sessions were studied and units were cleaned between patients according to the current hospital protocol. The surfaces most frequently contaminated after treatment were the 3-in-1 syringe buttons (40%), protective bibs (22%), tap handles (20%), light handles (18%) and operating cart handles (16%). Following cleaning of the units, the surfaces remaining contaminated were the 3-in-1 syringes (10%), tap handles (4%) and cart handles (2%). Modifications to the cross-infection control protocol have been made to eliminate these sources of contamination.
Lane, Christina; Torres, Julio; Flinn, Jane
2018-01-01
Environmental factors play a significant role in well-being of laboratory animals. Regulations and guidelines recommend, if not require, that stressors such as bright lighting, smells, and noises are eliminated or reduced to maximize animal well-being. A factor that is often overlooked is handling and how researchers interact with their animals. Researchers, lab assistants, and husbandry staff in animal facilities may use inconsistent handling methods when interacting with rodents, but humans should be considered a part of the animal's social environment. This study examined the effects of different handling techniques on depressive-like behavior, measured by the Porsolt forced swim test, in adult C57BL/6J male mice. The same two researchers handled the mice in a gentle, aggressive, or minimal (control) fashion over approximately two weeks prior to testing. The results demonstrated a beneficial effect of gentle handling: gentle handling reduced swimming immobility in the forced swim test compared to mice that were aggressively or minimally handled. We argue that gentle handling, rather than methodical handling, can foster a better relationship between the handlers and rodents. Although handling is not standardized across labs, consistent gentle handling allows for less challenging behavioral testing, better data collection, and overall improved animal welfare. PMID:29692869
Neely, Caroline; Lane, Christina; Torres, Julio; Flinn, Jane
2018-01-01
Environmental factors play a significant role in well-being of laboratory animals. Regulations and guidelines recommend, if not require, that stressors such as bright lighting, smells, and noises are eliminated or reduced to maximize animal well-being. A factor that is often overlooked is handling and how researchers interact with their animals. Researchers, lab assistants, and husbandry staff in animal facilities may use inconsistent handling methods when interacting with rodents, but humans should be considered a part of the animal's social environment. This study examined the effects of different handling techniques on depressive-like behavior, measured by the Porsolt forced swim test, in adult C57BL/6J male mice. The same two researchers handled the mice in a gentle, aggressive, or minimal (control) fashion over approximately two weeks prior to testing. The results demonstrated a beneficial effect of gentle handling: gentle handling reduced swimming immobility in the forced swim test compared to mice that were aggressively or minimally handled. We argue that gentle handling, rather than methodical handling, can foster a better relationship between the handlers and rodents. Although handling is not standardized across labs, consistent gentle handling allows for less challenging behavioral testing, better data collection, and overall improved animal welfare.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-04
... information can significantly expedite the handling of requests for assistance, resulting in both improved service to customers and enhanced capacity to handle inquiry volume. This information includes the plan... technological collection techniques or other forms of information technology, e.g., permitting electronic...
ERIC Educational Resources Information Center
Rendleman, Matt; Legacy, James
This publication provides an introduction to grain grading and handling for adult students in vocational and technical education programs. Organized in five chapters, the booklet provides a brief overview of the jobs performed at a grain elevator and of the techniques used to grade grain. The first chapter introduces the grain industry and…
Sakr, Sherif; Elshawi, Radwa; Ahmed, Amjad M; Qureshi, Waqas T; Brawner, Clinton A; Keteyian, Steven J; Blaha, Michael J; Al-Mallah, Mouaz H
2017-12-19
Prior studies have demonstrated that cardiorespiratory fitness (CRF) is a strong marker of cardiovascular health. Machine learning (ML) can enhance the prediction of outcomes through classification techniques that classify the data into predetermined categories. The aim of this study is to present an evaluation and comparison of how machine learning techniques can be applied on medical records of cardiorespiratory fitness and how the various techniques differ in terms of capabilities of predicting medical outcomes (e.g. mortality). We use data of 34,212 patients free of known coronary artery disease or heart failure who underwent clinician-referred exercise treadmill stress testing at Henry Ford Health Systems Between 1991 and 2009 and had a complete 10-year follow-up. Seven machine learning classification techniques were evaluated: Decision Tree (DT), Support Vector Machine (SVM), Artificial Neural Networks (ANN), Naïve Bayesian Classifier (BC), Bayesian Network (BN), K-Nearest Neighbor (KNN) and Random Forest (RF). In order to handle the imbalanced dataset used, the Synthetic Minority Over-Sampling Technique (SMOTE) is used. Two set of experiments have been conducted with and without the SMOTE sampling technique. On average over different evaluation metrics, SVM Classifier has shown the lowest performance while other models like BN, BC and DT performed better. The RF classifier has shown the best performance (AUC = 0.97) among all models trained using the SMOTE sampling. The results show that various ML techniques can significantly vary in terms of its performance for the different evaluation metrics. It is also not necessarily that the more complex the ML model, the more prediction accuracy can be achieved. The prediction performance of all models trained with SMOTE is much better than the performance of models trained without SMOTE. The study shows the potential of machine learning methods for predicting all-cause mortality using cardiorespiratory fitness data.
Orgovan, Norbert; Patko, Daniel; Hos, Csaba; Kurunczi, Sándor; Szabó, Bálint; Ramsden, Jeremy J; Horvath, Robert
2014-09-01
This paper gives an overview of the advantages and associated caveats of the most common sample handling methods in surface-sensitive chemical and biological sensing. We summarize the basic theoretical and practical considerations one faces when designing and assembling the fluidic part of the sensor devices. The influence of analyte size, the use of closed and flow-through cuvettes, the importance of flow rate, tubing length and diameter, bubble traps, pressure-driven pumping, cuvette dead volumes, and sample injection systems are all discussed. Typical application areas of particular arrangements are also highlighted, such as the monitoring of cellular adhesion, biomolecule adsorption-desorption and ligand-receptor affinity binding. Our work is a practical review in the sense that for every sample handling arrangement considered we present our own experimental data and critically review our experience with the given arrangement. In the experimental part we focus on sample handling in optical waveguide lightmode spectroscopy (OWLS) measurements, but the present study is equally applicable for other biosensing technologies in which an analyte in solution is captured at a surface and its presence is monitored. Explicit attention is given to features that are expected to play an increasingly decisive role in determining the reliability of (bio)chemical sensing measurements, such as analyte transport to the sensor surface; the distorting influence of dead volumes in the fluidic system; and the appropriate sample handling of cell suspensions (e.g. their quasi-simultaneous deposition). At the appropriate places, biological aspects closely related to fluidics (e.g. cellular mechanotransduction, competitive adsorption, blood flow in veins) are also discussed, particularly with regard to their models used in biosensing. Copyright © 2014 Elsevier B.V. All rights reserved.
System health monitoring using multiple-model adaptive estimation techniques
NASA Astrophysics Data System (ADS)
Sifford, Stanley Ryan
Monitoring system health for fault detection and diagnosis by tracking system parameters concurrently with state estimates is approached using a new multiple-model adaptive estimation (MMAE) method. This novel method is called GRid-based Adaptive Parameter Estimation (GRAPE). GRAPE expands existing MMAE methods by using new techniques to sample the parameter space. GRAPE expands on MMAE with the hypothesis that sample models can be applied and resampled without relying on a predefined set of models. GRAPE is initially implemented in a linear framework using Kalman filter models. A more generalized GRAPE formulation is presented using extended Kalman filter (EKF) models to represent nonlinear systems. GRAPE can handle both time invariant and time varying systems as it is designed to track parameter changes. Two techniques are presented to generate parameter samples for the parallel filter models. The first approach is called selected grid-based stratification (SGBS). SGBS divides the parameter space into equally spaced strata. The second approach uses Latin Hypercube Sampling (LHS) to determine the parameter locations and minimize the total number of required models. LHS is particularly useful when the parameter dimensions grow. Adding more parameters does not require the model count to increase for LHS. Each resample is independent of the prior sample set other than the location of the parameter estimate. SGBS and LHS can be used for both the initial sample and subsequent resamples. Furthermore, resamples are not required to use the same technique. Both techniques are demonstrated for both linear and nonlinear frameworks. The GRAPE framework further formalizes the parameter tracking process through a general approach for nonlinear systems. These additional methods allow GRAPE to either narrow the focus to converged values within a parameter range or expand the range in the appropriate direction to track the parameters outside the current parameter range boundary. Customizable rules define the specific resample behavior when the GRAPE parameter estimates converge. Convergence itself is determined from the derivatives of the parameter estimates using a simple moving average window to filter out noise. The system can be tuned to match the desired performance goals by making adjustments to parameters such as the sample size, convergence criteria, resample criteria, initial sampling method, resampling method, confidence in prior sample covariances, sample delay, and others.
UIAGM Ropehandling Techniques.
ERIC Educational Resources Information Center
Cloutier, K. Ross
The Union Internationale des Associations des Guides de Montagne's (UIAGM) rope handling techniques are intended to form the standard for guiding ropework worldwide. These techniques have become the legal standard for instructional institutions and commercial guiding organizations in UIAGM member countries: Austria, Canada, France, Germany, Great…
On the design of decoupling controllers for advanced rotorcraft in the hover case
NASA Technical Reports Server (NTRS)
Fan, M. K. H.; Tits, A.; Barlow, J.; Tsing, N. K.; Tischler, M.; Takahashi, M.
1991-01-01
A methodology for design of helicopter control systems is proposed that can account for various types of concurrent specifications: stability, decoupling between longitudinal and lateral motions, handling qualities, and physical limitations of the swashplate motions. This is achieved by synergistic use of analytical techniques (Q-parameterization of all stabilizing controllers, transfer function interpolation) and advanced numerical optimization techniques. The methodology is used to design a controller for the UH-60 helicopter in hover. Good results are achieved for decoupling and handling quality specifications.
Bruns-Toepler, Markus; Hardt, Philip
2017-07-01
The aims of the present study were: (i) Evaluate specificity and sensitivity of Hb Smart enzyme-linked immunosorbent assay (ELISA) (ScheBo Biotech) compared to colonoscopy results and (ii) assess stability of a new sample collection device containing a newly formulated buffer to extract haemoglobin using buffer and stool samples spiked with defined concentrations of haemoglobin. Stool samples were quantified with the ELISA method. The stability of haemoglobin in the extraction buffer and in native stool samples, respectively, was determined daily by ELISA during storage for 5 days at 4°C and at room temperature after addition of haemoglobin. Haemoglobin ELISA had a sensitivity of 78.4% for detection of CRC with a specificity of 98%. Haemoglobin extracted in corresponding extraction buffer demonstrated stability throughout storage for 5 days at 4°C and at room temperature. Hb Smart represents a very promising tool for large-scale screening of CRC with regard to sample handling, stability and analysis of haemoglobin in faeces. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Digital TV tri-state delta modulation system for Space Shuttle ku-band downlink
NASA Technical Reports Server (NTRS)
Udalov, S.; Huth, G. K.; Roberts, D.; Batson, B. H.
1982-01-01
A tri-state delta modulation/demodulation (TSDM) technique which provides for efficient run-length coding of constant-intensity segments of a TV picture is described. Aspects of the hardware implementation of a high-speed TSDM transmitter and receiver for black-and-white TV or field-sequential color or NTSC format color are reviewed. Run-length encoding of the TSDM output can consistently reduce the required channel data rate well below one bit per sample. As compared with a bistate delta modulation system, the present technique eliminates granularity in the reconstructed video without degrading rise or fall times. About 40 chips are used by TSDM when used to handle the luminance information in a color link. A possible overall space and ground functional configuration to accommodate Shuttle digital TV with scrambling for privacy is presented.
Sample Preparation Techniques for Grain Boundary Characterization of Annealed TRISO-Coated Particles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dunzik-Gougar, M. L.; van Rooyen, I. J.; Hill, C. M.
Crystallographic information about chemical vapor deposition layers of silicon carbide (SiC) is essential to understanding layer performance, especially when the layers are in non planar geometries, such as spherical. We performed electron Back Scatter Diffraction (EBSD) analysis of spherical SiC layers using a different approach to sample focus ion beam milling technique to avoid the negative impacts of traditional sample polishing and to address the need of very small samples of irradiated materials for analysis. Mechanical and chemical grinding and polishing of sample surfaces can introduce lattice strains and result in unequal removal of SiC and surrounding layers of differentmore » material due to the hardness differences of these materials. The nature of layer interfaces is thought to play a key role in performance of the SiC; therefore, analysis of representative samples at these interfacial areas is crucial. In work reported here, a focused ion beam (FIB) was employed in a novel manner to prepare a more representative sample for EBSD analysis from TRISO layers free of effects introduced by mechanical and chemical preparation methods. In addition, the difficulty of handling neutron irradiated microscopic samples such as those analyzed in this work has been simplified with pre tilted mounting stages. Our study showed that although the average grain size of samples may be similar, the grain boundary characteristics may differ significantly. It was also found that low angle grain boundaries, comprises 25% in the FIB-prepared sample vs only 1-2% in the polished sample measured in the same particle. From this study it was determined that results of FIB prepared sample will provide more repeatable results, as the role of sample preparation is eliminated.« less
Sample Preparation Techniques for Grain Boundary Characterization of Annealed TRISO-Coated Particles
Dunzik-Gougar, M. L.; van Rooyen, I. J.; Hill, C. M.; ...
2016-08-25
Crystallographic information about chemical vapor deposition layers of silicon carbide (SiC) is essential to understanding layer performance, especially when the layers are in non planar geometries, such as spherical. We performed electron Back Scatter Diffraction (EBSD) analysis of spherical SiC layers using a different approach to sample focus ion beam milling technique to avoid the negative impacts of traditional sample polishing and to address the need of very small samples of irradiated materials for analysis. Mechanical and chemical grinding and polishing of sample surfaces can introduce lattice strains and result in unequal removal of SiC and surrounding layers of differentmore » material due to the hardness differences of these materials. The nature of layer interfaces is thought to play a key role in performance of the SiC; therefore, analysis of representative samples at these interfacial areas is crucial. In work reported here, a focused ion beam (FIB) was employed in a novel manner to prepare a more representative sample for EBSD analysis from TRISO layers free of effects introduced by mechanical and chemical preparation methods. In addition, the difficulty of handling neutron irradiated microscopic samples such as those analyzed in this work has been simplified with pre tilted mounting stages. Our study showed that although the average grain size of samples may be similar, the grain boundary characteristics may differ significantly. It was also found that low angle grain boundaries, comprises 25% in the FIB-prepared sample vs only 1-2% in the polished sample measured in the same particle. From this study it was determined that results of FIB prepared sample will provide more repeatable results, as the role of sample preparation is eliminated.« less
Fourth NASA Inter-Center Control Systems Conference
NASA Technical Reports Server (NTRS)
1978-01-01
Space vehicle control applications are discussed, along with aircraft guidance, control, and handling qualities. System simulation and identification, engine control, advanced propulsion techniques, and advanced control techniques are also included.
Microbiological quality and safe handling of enteral diets in a hospital in Minas Gerais, Brazil.
Pinto, Raquel Oliveira Medrado; Correia, Eliznara Fernades; Pereira, Keyla Carvalho; Costa Sobrinho, Paulo de Souza; da Silva, Daniele Ferreira
2015-06-01
Contamination of enteral diets represents a high risk of compromising the patient's medical condition. To assess the microbiological quality and aseptic conditions in the preparation and administration of handmade and industrialized enteral diets offered in a hospital in the Valley of Jequitinhonha, MG, Brazil, we performed a microbiological analysis of 50 samples of diets and 27 samples of surfaces, utensils, and water used in the preparation of the diets. In addition, we assessed the good handling practices of enteral diets according to the requirements specified by the Brazilian legislation. Both kinds of enteral diets showed contamination by coliforms and Pseudomonas spp. No sample was positive for Staphylococcus aureus and Salmonella spp. On the other hand, Listeria spp. was detected in only one sample of handmade diets. Contamination was significantly higher in the handmade preparations (p < 0.05). Nonconformities were detected with respect to good handling practices, which may compromise the diet safety. The results indicate that the sanitary quality of the enteral diets is unsatisfactory, especially handmade diets. Contamination by Pseudomonas spp. is significant because it is often involved in infection episodes. With regard to aseptic practices, it was observed the need of implementing new procedures for handling enteral diets.
Villanger, Gro Dehli; Learner, Emily; Longnecker, Matthew P; Ask, Helga; Aase, Heidi; Zoeller, R Thomas; Knudsen, Gun P; Reichborn-Kjennerud, Ted; Zeiner, Pål; Engel, Stephanie M
2017-05-01
Maternal thyroid function is a critical mediator of fetal brain development. Pregnancy-related physiologic changes and handling conditions of blood samples may influence thyroid hormone biomarkers. We investigated the reliability of thyroid hormone biomarkers in plasma of pregnant women under various handling conditions. We enrolled 17 pregnant women; collected serum and plasma were immediately frozen. Additional plasma aliquots were subjected to different handling conditions before the analysis of thyroid biomarkers: storage at room temperature for 24 or 48 hours before freezing and an extra freeze-thaw cycle. We estimated free thyroid hormone indices in plasma based on T3 uptake. High correlations between plasma and serum (>0.94) and intraclass correlation coefficients for plasma handling conditions (0.96 to 1.00) indicated excellent reliability for all thyroid hormone biomarkers. Delayed freezing and freeze-thaw cycles did not affect reliability of biomarkers of thyroid function in plasma during pregnancy. See video abstract at, http://links.lww.com/EDE/B180.
Sample Preparation for Electron Probe Microanalysis—Pushing the Limits
Geller, Joseph D.; Engle, Paul D.
2002-01-01
There are two fundamental considerations in preparing samples for electron probe microanalysis (EPMA). The first one may seem obvious, but we often find it is overlooked. That is, the sample analyzed should be representative of the population from which it comes. The second is a direct result of the assumptions in the calculations used to convert x-ray intensity ratios, between the sample and standard, to concentrations. Samples originate from a wide range of sources. During their journey to being excited under the electron beam for the production of x rays there are many possibilities for sample alteration. Handling can contaminate samples by adding extraneous matter. In preparation, the various abrasives used in sizing the sample by sawing, grinding and polishing can embed themselves. The most accurate composition of a contaminated sample is, at best, not representative of the original sample; it is misleading. Our laboratory performs EPMA analysis on customer submitted samples and prepares over 250 different calibration standards including pure elements, compounds, alloys, glasses and minerals. This large variety of samples does not lend itself to mass production techniques, including automatic polishing. Our manual preparation techniques are designed individually for each sample. The use of automated preparation equipment does not lend itself to this environment, and is not included in this manuscript. The final step in quantitative electron probe microanalysis is the conversion of x-ray intensities ratios, known as the “k-ratios,” to composition (in mass fraction or atomic percent) and/or film thickness. Of the many assumptions made in the ZAF (where these letters stand for atomic number, absorption and fluorescence) corrections the localized geometry between the sample and electron beam, or takeoff angle, must be accurately known. Small angular errors can lead to significant errors in the final results. The sample preparation technique then becomes very important, and, under certain conditions, may even be the limiting factor in the analytical uncertainty budget. This paper considers preparing samples to get known geometries. It will not address the analysis of samples with irregular, unprepared surfaces or unknown geometries. PMID:27446757
Extended Importance Sampling for Reliability Analysis under Evidence Theory
NASA Astrophysics Data System (ADS)
Yuan, X. K.; Chen, B.; Zhang, B. Q.
2018-05-01
In early engineering practice, the lack of data and information makes uncertainty difficult to deal with. However, evidence theory has been proposed to handle uncertainty with limited information as an alternative way to traditional probability theory. In this contribution, a simulation-based approach, called ‘Extended importance sampling’, is proposed based on evidence theory to handle problems with epistemic uncertainty. The proposed approach stems from the traditional importance sampling for reliability analysis under probability theory, and is developed to handle the problem with epistemic uncertainty. It first introduces a nominal instrumental probability density function (PDF) for every epistemic uncertainty variable, and thus an ‘equivalent’ reliability problem under probability theory is obtained. Then the samples of these variables are generated in a way of importance sampling. Based on these samples, the plausibility and belief (upper and lower bounds of probability) can be estimated. It is more efficient than direct Monte Carlo simulation. Numerical and engineering examples are given to illustrate the efficiency and feasible of the proposed approach.
IS GUTTACORE MORE EASILY REMOVED FROM THE ROOT CANAL THAN THERMAFIL? AN EX-VIVO STUDY.
Nevares, Giselle; de Albuquerque, Diana Santana; Bueno, Carlos Eduardo da Silveira; Cunha, Rodrigo Sanches
2015-01-01
GuttaCore is a new cross-linked gutta-percha carrier. Its handling time and ease of removal were compared with those of a plastic carrier (Thermafil) and the continuous wave of condensation technique (control). Forty-five maxillary central incisors were randomly divided 3 groups according to filling technique and retreatment was carried out in all samples with NiTi rotary files, hand files and ultrasonic inserts. Time required for filling removal was recorded. Roots were then split longitudinally and photographed under 5x magnification, and residual filling material was quantified. Removal time was significantly longer for Thermafil (7.10 minutes) than GuttaCore (2.91 minutes) and the control group (1.93 minutes) (p < 0.001). The amount of residual filling material did not differ among the groups: Thermafil 8.31%, GuttaCore 6.27 and control 8.68% (p > 0.05). In conclusion, replacing plastic core with cross-linked gutta-percha allows easier removal of carrier from the root canal. The remnants of filling material in all samples illustrate that retreatment remains a challenge in endodontics.
Sample Handling and Instruments for the In-Situ Exploration of Ice-Rich Planets. Chapter 9
NASA Technical Reports Server (NTRS)
Castillo, Julie C.; Bar-Cohen, Yoseph; Vance, Steve; Choukroun, Mathieu; Lee, Hyeong Jae; Bao, Xiaoqi; Badescu, Mircea; Sherrit, Stewart; Trainer, Melissa G.; Getty, Stephanie A.
2016-01-01
NASA's key science goals for the exploration of the solar system seek a better understanding of the formation and evolutionary processes that have shaped planetary bodies and emphasize the search for habitable environments. Efforts are also made to detect and quantify resources that could be used for the support of human exploration. These themes call for chemistry and physical property observations that may be best approached by in situ measurements. NASA's planetary missions have progressively evolved from remote reconnaissance to in situ exploration with the ultimate goal to return samples. This chapter focuses on the techniques, available or in development, for advanced geophysical and chemical characterization of icy bodies, especially Mars polar areas, Enceladus, Titan, Europa, and Ceres. These astrobiological targets are the objects of recent or ongoing exploration whose findings are driving the formulation of new missions that involve in situ exploration. After reviewing the overall objectives of icy body exploration (Section 9.1) we describe key techniques used for addressing these objectives from surface platforms via geophysical observations (Section 9.2) and chemical measurements (Section 9.3).
Status and path to a final EUVL reticle-handling solution
NASA Astrophysics Data System (ADS)
He, Long; Orvek, Kevin; Seidel, Phil; Wurm, Stefan; Underwood, Jon; Betancourt, Ernie
2007-03-01
In extreme ultraviolet lithography (EUVL), the lack of a suitable material to build conventional pellicles calls for industry standardization of new techniques for protection and handling throughout the reticle's lifetime. This includes reticle shipping, robotic handling, in-fab transport, storage, and uses in atmospheric environments for metrology and vacuum environments for EUV exposure. In this paper, we review the status of the industry-wide progress in developing EUVL reticle-handling solutions. We show the industry's leading reticle carrier approaches for particle-free protection, such as improvements in conventional single carrier designs and new EUVL-specific carrier concepts, including variations on a removable pellicle. Our test indicates dual pod approach of the removable pellicle led to nearly particle-free use during a simulated life cycle, at ~50nm inspection sensitivity. We will provide an assessment of the remaining technical challenges facing EUVL reticle-handling technology. Finally, we will review the progress of the SEMI EUVL Reticle-handling Task Force in its efforts to standardize a final EUV reticle protection and handling solution.
On the use of The Bio-Impedance technique for Body Composition Measurements
NASA Astrophysics Data System (ADS)
Huerta-Franco, R.; Vargas-Luna, M.; González-Solís, J. L.; Gutiérrez-Juárez, G.
2003-09-01
Reviewing the methods and physical principles used in body composition measurements (BCM), it is evident that more accurate, reliable, and easily handled methods are required. The use of bio-impedance analysis (BIA) has been very useful in BCM. This technique, in the single frequency mode, has some commercial versions to perform BCM. However these apparatus have significant variability in the BCM values. The multi-frequency option of the bio-impedance technique has still a lot of challenges to overcome. We studied the variability of the body impedance spectrum (from 1 Hz to 1 MHz) in a group of subjects compared to the values obtained from commercial apparatus. We compared different anatomical body regions, some of them with less subcutaneous body fat (frontal, anterior tibial, knee, and frontal regions); others with more subcutaneous body fat (pectoral, abdominal, and internal calf regions). In order to model the bio-impedance spectrum, we analyzed layered samples with different thickness and material composition.
Low-cost cryo-light microscopy stage fabrication for correlated light/electron microscopy.
Carlson, David B; Evans, James E
2011-06-05
The coupling of cryo-light microscopy (cryo-LM) and cryo-electron microscopy (cryo-EM) poses a number of advantages for understanding cellular dynamics and ultrastructure. First, cells can be imaged in a near native environment for both techniques. Second, due to the vitrification process, samples are preserved by rapid physical immobilization rather than slow chemical fixation. Third, imaging the same sample with both cryo-LM and cryo-EM provides correlation of data from a single cell, rather than a comparison of "representative samples". While these benefits are well known from prior studies, the widespread use of correlative cryo-LM and cryo-EM remains limited due to the expense and complexity of buying or building a suitable cryogenic light microscopy stage. Here we demonstrate the assembly, and use of an inexpensive cryogenic stage that can be fabricated in any lab for less than $40 with parts found at local hardware and grocery stores. This cryo-LM stage is designed for use with reflected light microscopes that are fitted with long working distance air objectives. For correlative cryo-LM and cryo-EM studies, we adapt the use of carbon coated standard 3-mm cryo-EM grids as specimen supports. After adsorbing the sample to the grid, previously established protocols for vitrifying the sample and transferring/handling the grid are followed to permit multi-technique imaging. As a result, this setup allows any laboratory with a reflected light microscope to have access to direct correlative imaging of frozen hydrated samples.
In Situ Solid Particle Generator
NASA Technical Reports Server (NTRS)
Agui, Juan H.; Vijayakumar, R.
2013-01-01
Particle seeding is a key diagnostic component of filter testing and flow imaging techniques. Typical particle generators rely on pressurized air or gas sources to propel the particles into the flow field. Other techniques involve liquid droplet atomizers. These conventional techniques have drawbacks that include challenging access to the flow field, flow and pressure disturbances to the investigated flow, and they are prohibitive in high-temperature, non-standard, extreme, and closed-system flow conditions and environments. In this concept, the particles are supplied directly within a flow environment. A particle sample cartridge containing the particles is positioned somewhere inside the flow field. The particles are ejected into the flow by mechanical brush/wiper feeding and sieving that takes place within the cartridge chamber. Some aspects of this concept are based on established material handling techniques, but they have not been used previously in the current configuration, in combination with flow seeding concepts, and in the current operational mode. Unlike other particle generation methods, this concept has control over the particle size range ejected, breaks up agglomerates, and is gravity-independent. This makes this device useful for testing in microgravity environments.
Goode, Natassia; Salmon, Paul M; Lenné, Michael G; Hillard, Peter
2014-07-01
Injuries resulting from manual handling tasks represent an on-going problem for the transport and storage industry. This article describes an application of a systems theory-based approach, Rasmussen's (1997. Safety Science 27, 183), risk management framework, to the analysis of the factors influencing safety during manual handling activities in a freight handling organisation. Observations of manual handling activities, cognitive decision method interviews with workers (n=27) and interviews with managers (n=35) were used to gather information about three manual handling activities. Hierarchical task analysis and thematic analysis were used to identify potential risk factors and performance shaping factors across the levels of Rasmussen's framework. These different data sources were then integrated using Rasmussen's Accimap technique to provide an overall analysis of the factors influencing safety during manual handling activities in this context. The findings demonstrate how a systems theory-based approach can be applied to this domain, and suggest that policy-orientated, rather than worker-orientated, changes are required to prevent future manual handling injuries. Copyright © 2013 Elsevier Ltd. All rights reserved.
Laboratory rearing and handling of cerambycids
Melody A. Keena
2017-01-01
Lack of suitable rearing and handling techniques has hampered research on the biology and control of many species of cerambycids that feed on host species of economic importance. Furthermore, because cerambycids spend most or all of their pre-adult life cycle inside the host plant, the biology of many is not well-known and would be dif
AUTOMATED LITERATURE PROCESSING HANDLING AND ANALYSIS SYSTEM--FIRST GENERATION.
ERIC Educational Resources Information Center
Redstone Scientific Information Center, Redstone Arsenal, AL.
THE REPORT PRESENTS A SUMMARY OF THE DEVELOPMENT AND THE CHARACTERISTICS OF THE FIRST GENERATION OF THE AUTOMATED LITERATURE PROCESSING, HANDLING AND ANALYSIS (ALPHA-1) SYSTEM. DESCRIPTIONS OF THE COMPUTER TECHNOLOGY OF ALPHA-1 AND THE USE OF THIS AUTOMATED LIBRARY TECHNIQUE ARE PRESENTED. EACH OF THE SUBSYSTEMS AND MODULES NOW IN OPERATION ARE…
Safety and maintenance engineering: A compilation
NASA Technical Reports Server (NTRS)
1974-01-01
A compilation is presented for the dissemination of information on technological developments which have potential utility outside the aerospace and nuclear communities. Safety of personnel engaged in the handling of hazardous materials and equipment, protection of equipment from fire, high wind, or careless handling by personnel, and techniques for the maintenance of operating equipment are reported.
Yurtkuran, Alkın; Emel, Erdal
2014-01-01
The traveling salesman problem with time windows (TSPTW) is a variant of the traveling salesman problem in which each customer should be visited within a given time window. In this paper, we propose an electromagnetism-like algorithm (EMA) that uses a new constraint handling technique to minimize the travel cost in TSPTW problems. The EMA utilizes the attraction-repulsion mechanism between charged particles in a multidimensional space for global optimization. This paper investigates the problem-specific constraint handling capability of the EMA framework using a new variable bounding strategy, in which real-coded particle's boundary constraints associated with the corresponding time windows of customers, is introduced and combined with the penalty approach to eliminate infeasibilities regarding time window violations. The performance of the proposed algorithm and the effectiveness of the constraint handling technique have been studied extensively, comparing it to that of state-of-the-art metaheuristics using several sets of benchmark problems reported in the literature. The results of the numerical experiments show that the EMA generates feasible and near-optimal results within shorter computational times compared to the test algorithms.
Yurtkuran, Alkın
2014-01-01
The traveling salesman problem with time windows (TSPTW) is a variant of the traveling salesman problem in which each customer should be visited within a given time window. In this paper, we propose an electromagnetism-like algorithm (EMA) that uses a new constraint handling technique to minimize the travel cost in TSPTW problems. The EMA utilizes the attraction-repulsion mechanism between charged particles in a multidimensional space for global optimization. This paper investigates the problem-specific constraint handling capability of the EMA framework using a new variable bounding strategy, in which real-coded particle's boundary constraints associated with the corresponding time windows of customers, is introduced and combined with the penalty approach to eliminate infeasibilities regarding time window violations. The performance of the proposed algorithm and the effectiveness of the constraint handling technique have been studied extensively, comparing it to that of state-of-the-art metaheuristics using several sets of benchmark problems reported in the literature. The results of the numerical experiments show that the EMA generates feasible and near-optimal results within shorter computational times compared to the test algorithms. PMID:24723834
An Injectable Glass Polyalkenoate Cement Engineered for Fracture Fixation and Stabilization
Peel, Sean A. F.; Towler, Mark R.
2017-01-01
Glass polyalkenoate cements (GPCs) have potential as bio-adhesives due to their ease of application, appropriate mechanical properties, radiopacity and chemical adhesion to bone. Aluminium (Al)-free GPCs have been discussed in the literature, but have proven difficult to balance injectability with mechanical integrity. For example, zinc-based, Al-free GPCs reported compressive strengths of 63 MPa, but set in under 2 min. Here, the authors design injectable GPCs (IGPCs) based on zinc-containing, Al-free silicate compositions containing GeO2, substituted for ZnO at 3% increments through the series. The setting reactions, injectability and mechanical properties of these GPCs were evaluated using both a hand-mix (h) technique, using a spatula for sample preparation and application and an injection (i) technique, using a 16-gauge needle, post mixing, for application. GPCs ability to act as a carrier for bovine serum albumin (BSA) was also evaluated. Germanium (Ge) and BSA containing IGPCs were produced and reported to have working times between 26 and 44 min and setting times between 37 and 55 min; the extended handling properties being as a result of less Ge. The incorporation of BSA into the cement had no effect on the handling and mechanical properties, but the latter were found to have increased compression strength with the addition of Ge from between 27 and 37 MPa after 30 days maturation. PMID:28678157
An Optimized Small Tissue Handling System for Immunohistochemistry and In Situ Hybridization
Anthony, Giovanni; Lee, Ju-Ahng
2016-01-01
Recent development in 3D printing technology has opened an exciting possibility for manufacturing 3D devices on one’s desktop. We used 3D modeling programs to design 3D models of a tissue-handling system and these models were “printed” in a stereolithography (SLA) 3D printer to create precision histology devices that are particularly useful to handle multiple samples with small dimensions in parallel. Our system has been successfully tested for in situ hybridization of zebrafish embryos. Some of the notable features include: (1) A conveniently transferrable chamber with 6 mesh-bottomed wells, each of which can hold dozens of zebrafish embryos. This design allows up to 6 different samples to be treated per chamber. (2) Each chamber sits in a well of a standard 6-well tissue culture plate. Thus, up to 36 different samples can be processed in tandem using a single 6 well plate. (3) Precisely fitting lids prevent solution evaporation and condensation, even at high temperatures for an extended period of time: i.e., overnight riboprobe hybridization. (4) Flat bottom mesh maximizes the consistent treatment of individual tissue samples. (5) A magnet-based lifter was created to handle up to 6 chambers (= 36 samples) in unison. (6) The largely transparent resin aids in convenient visual inspection both with eyes and using a stereomicroscope. (7) Surface engraved labeling enables an accurate tracking of different samples. (8) The dimension of wells and chambers minimizes the required amount of precious reagents. (9) Flexible parametric modeling enables an easy redesign of the 3D models to handle larger or more numerous samples. Precise dimensions of 3D models and demonstration of how we use our devices in whole mount in situ hybridization are presented. We also provide detailed information on the modeling software, 3D printing tips, as well as 3D files that can be used with any 3D printer. PMID:27489962
NASA Astrophysics Data System (ADS)
Ovaysi, S.; Piri, M.
2009-12-01
We present a three-dimensional fully dynamic parallel particle-based model for direct pore-level simulation of incompressible viscous fluid flow in disordered porous media. The model was developed from scratch and is capable of simulating flow directly in three-dimensional high-resolution microtomography images of naturally occurring or man-made porous systems. It reads the images as input where the position of the solid walls are given. The entire medium, i.e., solid and fluid, is then discretized using particles. The model is based on Moving Particle Semi-implicit (MPS) technique. We modify this technique in order to improve its stability. The model handles highly irregular fluid-solid boundaries effectively. It takes into account viscous pressure drop in addition to the gravity forces. It conserves mass and can automatically detect any false connectivity with fluid particles in the neighboring pores and throats. It includes a sophisticated algorithm to automatically split and merge particles to maintain hydraulic connectivity of extremely narrow conduits. Furthermore, it uses novel methods to handle particle inconsistencies and open boundaries. To handle the computational load, we present a fully parallel version of the model that runs on distributed memory computer clusters and exhibits excellent scalability. The model is used to simulate unsteady-state flow problems under different conditions starting from straight noncircular capillary tubes with different cross-sectional shapes, i.e., circular/elliptical, square/rectangular and triangular cross-sections. We compare the predicted dimensionless hydraulic conductances with the data available in the literature and observe an excellent agreement. We then test the scalability of our parallel model with two samples of an artificial sandstone, samples A and B, with different volumes and different distributions (non-uniform and uniform) of solid particles among the processors. An excellent linear scalability is obtained for sample B that has more uniform distribution of solid particles leading to a superior load balancing. The model is then used to simulate fluid flow directly in REV size three-dimensional x-ray images of a naturally occurring sandstone. We analyze the quality and consistency of the predicted flow behavior and calculate absolute permeability, which compares well with the available network modeling and Lattice-Boltzmann permeabilities available in the literature for the same sandstone. We show that the model conserves mass very well and is stable computationally even at very narrow fluid conduits. The transient- and the steady-state fluid flow patterns are presented as well as the steady-state flow rates to compute absolute permeability. Furthermore, we discuss the vital role of our adaptive particle resolution scheme in preserving the original pore connectivity of the samples and their narrow channels through splitting and merging of fluid particles.
Neonatal handling reduces renal function in adult rats.
Donadio, Márcio Vinícius Fagundes; Jacobs, Silvana; Corezola, Kizzy Ludnila; Melo, Denizar Alberto da Silva; Dias, Henrique Bregolin; Reichel, Carlos Luiz; Franci, Celso Rodrigues; Jeckel-Neto, Emilio Antonio; Lulhier, Francisco; Lucion, Aldo Bolten; de Oliveira, Jarbas Rodrigues; Sanvitto, Gilberto Luiz
2009-01-01
To evaluate the effects of neonatal handling on hydroelectrolytic balance in adult rats. The litters were divided into two groups: nonhandled and handled. The procedure consisted of handling the pups for 1 min/day in the first 10 days postnatally. When adults, animals had their body weight verified and were housed in individual metabolic cages. After a 24-hour period, urine samples were collected and the urinary and water intake volumes measured. Blood samples to determine osmolality, aldosterone, corticosterone, angiotensin II, creatinine, urea, sodium and potassium levels were collected. The kidneys were removed for histological assessment. Urinary osmolality, sodium, urea and creatinine were also measured and the creatinine clearance (CC) calculated. No difference between groups was found in the body weight. Handled animals showed a reduction in the total kidney wet weight, water intake, urinary volume, CC, plasma angiotensin II, corticosterone and aldosterone when compared to the nonhandled and an increase in the urinary osmolality and sodium excretion fraction. No differences in serum potassium and no evidence of structural changes were demonstrated by histological analysis. Neonatal handling induced long-lasting effects decreasing renal function without evidence of kidney structural changes. (c) 2009 S. Karger AG, Basel.
Supercritical fluids as alternative, safe, food-processing media: an overview.
Da Cruz Francisco, José; Szwajcer Dey, Estera
2003-01-01
The continuous growth of world population and its concentration in the urban areas require food supplies that are continuous, sufficient and of good quality. To resolve this problem techniques have been developed for increasing food quantity and quality. The techniques are applied throughout the food chain from production, conservation and during distribution to the consumers (from "the field to the fork"). During handling of food, chemicals are often deliberately added to achieve improved processing and better quality. This is one of the main reasons food undergoes different kinds of contamination. This overview focuses on the application of supercritical fluids as media for handling food materials during processing with the perspective of reducing chemical contamination of food. Examples of developmental applications of this technique and on research work in process are presented. Emphasis is given to extraction and biotransformation techniques.
Uncertainties in internal gas counting
NASA Astrophysics Data System (ADS)
Unterweger, M.; Johansson, L.; Karam, L.; Rodrigues, M.; Yunoki, A.
2015-06-01
The uncertainties in internal gas counting will be broken down into counting uncertainties and gas handling uncertainties. Counting statistics, spectrum analysis, and electronic uncertainties will be discussed with respect to the actual counting of the activity. The effects of the gas handling and quantities of counting and sample gases on the uncertainty in the determination of the activity will be included when describing the uncertainties arising in the sample preparation.
Raterink, Robert-Jan; Witkam, Yoeri; Vreeken, Rob J; Ramautar, Rawi; Hankemeier, Thomas
2014-10-21
In the field of bioanalysis, there is an increasing demand for miniaturized, automated, robust sample pretreatment procedures that can be easily connected to direct-infusion mass spectrometry (DI-MS) in order to allow the high-throughput screening of drugs and/or their metabolites in complex body fluids like plasma. Liquid-Liquid extraction (LLE) is a common sample pretreatment technique often used for complex aqueous samples in bioanalysis. Despite significant developments that have been made in automated and miniaturized LLE procedures, fully automated LLE techniques allowing high-throughput bioanalytical studies on small-volume samples using direct infusion mass spectrometry, have not been matured yet. Here, we introduce a new fully automated micro-LLE technique based on gas-pressure assisted mixing followed by passive phase separation, coupled online to nanoelectrospray-DI-MS. Our method was characterized by varying the gas flow and its duration through the solvent mixture. For evaluation of the analytical performance, four drugs were spiked to human plasma, resulting in highly acceptable precision (RSD down to 9%) and linearity (R(2) ranging from 0.990 to 0.998). We demonstrate that our new method does not only allow the reliable extraction of analytes from small sample volumes of a few microliters in an automated and high-throughput manner, but also performs comparable or better than conventional offline LLE, in which the handling of small volumes remains challenging. Finally, we demonstrate the applicability of our method for drug screening on dried blood spots showing excellent linearity (R(2) of 0.998) and precision (RSD of 9%). In conclusion, we present the proof of principe of a new high-throughput screening platform for bioanalysis based on a new automated microLLE method, coupled online to a commercially available nano-ESI-DI-MS.
NASA Technical Reports Server (NTRS)
Zolensky, M. E.; Lindstrom, David J.; Lindstrom, Richard M.; Lindstrom, M. M.
1989-01-01
Today the major elemental composition of interplanetary dust particles (IDPs) is routinely determined in many laboratories. These and mineralogical studies have revealed the presence of at least two major types of IDPs, chondritic and refractory. Preliminary results of a successful attempt to determine abundances of a large suite of trace elements from both chondritic and refractory IDPs are reported. The analytical procedure can be used in the grain-by-grain analysis of returned cometary samples. Chondritic and refractory IDPs are characterized by standard scanning electron microscopy and energy dispersive x ray spectroscopy (SEM-EDX) techniques. With this system, detection limits for many elements are well below picogram levels, and some approach femtogram levels. This technique is non-destructive, although some sample handling is required, so particles can be analyzed by other techniques after instrument neutron activation analysis (INAA) is completed. Data is presently being reduced from the analyses of 7 IDPs. These are U2015E10, U2015F1, W7029-A2, W7029-A3, W7013A8, LACl (all chondritic) and 705 (refractory). So far, 17 different major and trace elements were detected and measured in these particles, including rare earths and some very volatile elements (Br and Zn).
NASA Astrophysics Data System (ADS)
Tan, Shuai; Cheng, Yongqiang; Daemen, Luke L.; Lutterman, Daniel A.
2018-01-01
Catalysis is a critical enabling science for future energy needs. The next frontier of catalysis is to evolve from catalyst discovery to catalyst design, and for this next step to be realized, we must develop new techniques to better understand reaction mechanisms. To do this, we must connect catalytic reaction rates and selectivities to the kinetics, energetics, and dynamics of individual elementary steps and relate these to the structure and dynamics of the catalytic sites involved. Neutron scattering spectroscopies offer unique capabilities that are difficult or impossible to match by other techniques. The current study presents the development of a compact and portable instrumental design that enables the in situ investigation of catalytic samples by neutron scattering techniques. The developed apparatus was tested at the Spallation Neutron Source (SNS) in Oak Ridge National Laboratory and includes a gas handling panel that allows for computer hookups to control the panel externally and online measurement equipment such as coupled GC-FID/TCD (Gas Chromatography-Flame Ionization Detector/Thermal Conductivity Detector) and MS (Mass Spectrometry) to characterize offgassing while the sample is in the neutron scattering spectrometer. This system is flexible, modular, compact, and portable enabling its use for many types of gas-solid and liquid-solid reactions at the various beamlines housed at the SNS.
Braun, Elizabeth I; Huang, An; Tusa, Carolyn A; Yukica, Michael A; Pantano, Paul
2016-12-01
Carbon nanotubes (CNTs) are cylindrical molecules of carbon with diverse commercial applications. CNTs are also lightweight, easily airborne, and have been shown to be released during various phases of production and use. Therefore, as global CNT production increases, so do concerns that CNTs could pose a safety threat to those who are exposed to them. This makes it imperative to fully understand CNT release scenarios to make accurate risk assessments and to implement effective control measures. However, the current suite of direct-reading and off-line instrumentation used to monitor the release of CNTs in workplaces lack high chemical specificity, which complicates risk assessments when the sampling and/or measurements are performed at a single site where multiple CNT types are handled in the presence of naturally occurring background particles, or dust. Herein, we demonstrate the utility of Raman spectroscopy to unequivocally identify whether particulate matter collected from a multi-user analytical balance workstation comprised CNTs, as well as, whether the contamination included CNTs that were synthesized by a Ni/Y-catalyzed electric-arc method or a Co/Mo-catalyzed chemical vapor deposition method. Identifying the exact CNT type generated a more accurate risk assessment by knowing the metallic impurities involved, and it also led to the identification of the users who handled these CNTs, a review of their handling techniques, and an improved protocol for safely weighing CNTs.
Determination of 129I in environmental samples by AMS and NAA using an anion exchange resin disk
NASA Astrophysics Data System (ADS)
Suzuki, Takashi; Banba, Shigeru; Kitamura, Toshikatsu; Kabuto, Shoji; Isogai, Keisuke; Amano, Hikaru
2007-06-01
We have developed a new extraction method for the measurement of 129I by accelerator mass spectrometry (AMS) utilizing an anion exchange resin disk. In comparison to traditional methods such as solvent extraction and ion exchange, this method provides for simple and quick sample handling. This extraction method was tested on soil, seaweed and milk samples, but because of disk clogging, the milk samples and some of the seaweed could not be applied successfully. Using this new extraction method to prepare samples for AMS analysis produced isotope ratios of iodine in good agreement with neutron activation analysis (NAA). The disk extraction method which take half an hour is faster than previous techniques, such as solvent extraction or ion exchange which take a few hours. The combination of the disk method and the AMS measurement is a powerful tool for the determination of 129I. Furthermore, these data will be available for the environmental monitoring before and during the operation of a new nuclear fuel reprocessing plant in Japan.
Cleaning at the Edge of Science: NASA's Genesis Mission
NASA Technical Reports Server (NTRS)
Stansbery, Eileen K.; Biesinger, Paul H.
2000-01-01
As part of NASA's continuing exploration of the origins of our solar system, the California Institute of Technology, Jet Propulsion Laboratory, Lockheed Martin Astronautics, Los Alamos National Laboratory, and the Johnson Space Center are working together to develop the Genesis mission to return solar matter for analysis in terrestrial laboratories. These samples will be used to define a baseline for the chemical and isotopic composition of the solar nebula. Deviations from the baseline resulted as the solar system evolved; thus, providing a tracer for materials incorporated into meteorites, comets and planetary bodies. These differences represent "fossil residues" that provide invaluable insight into how the solar nebula evolved to form the planets. We cannot collect a sample of the Sun as we would for a planet; fortunately, solar material comes to us in the form of the solar wind. Ultrapure materials will be exposed at the Earth-Sun L1, outside the Earth's magnetic influence, where solar wind nuclei will be captured for 2 years before returning to Earth in January 2001. The key challenge to obtaining a good sample of solar wind, uncontaminated by terrestrial atoms, is a clean collection surface in a clean sample canister and clean facilities with which to handle the samples for allocation and future reference. The Johnson Space Center QSQ is responsible for contamination control for the mission, for ensuring the cleanliness of collection surfaces and providing a clean environment for their subsequent handling. The level of cleanliness required is high; at the time of analysis (after sample return), the surface contamination by C, N, O must each be less than 10(exp 15) atoms per centimeter squared and for elements other than C, N, O, the number of atoms per centimeter squared of each surface contaminant shall not exceed the estimated solar wind fluence of the species (varies by element between U at approx. 10 (exp 4) atoms per centimeter squared to Fe, Si, Mg, and Ne at approx. 10(exp 12), atoms per centimeter squared). Typical spacecraft assembly is done in class 10,000 cleanrooms. The final cleaning and reintegration of the Genesis payload canister as well as all sample material handling will be done within a class 10 cleanroom using Dryden suits to protect the collector materials from any human debris. Each component is unique, no standard size, shape, material, or precleaning history. We are developing new final cleaning techniques utilizing ultra-pure water to minimize molecular residues on the hardware components.
Hathaway, John C.
1971-01-01
The purpose of the data file presented below is twofold: the first purpose is to make available in printed form the basic data relating to the samples collected as part of the joint U.S. Geological Survey - Woods Hole Oceanographic Institution program of study of the Atlantic continental margin of the United States; the second purpose is to maintain these data in a form that is easily retrievable by modern computer methods. With the data in such form, repeate manual transcription for statistical or similar mathematical treatment becomes unnecessary. Manual plotting of information or derivatives from the information may also be eliminated. Not only is handling of data by the computer considerably faster than manual techniques, but a fruitful source of errors, transcription mistakes, is eliminated.
Missing Data in the Field of Otorhinolaryngology and Head & Neck Surgery: Need for Improvement.
Netten, Anouk P; Dekker, Friedo W; Rieffe, Carolien; Soede, Wim; Briaire, Jeroen J; Frijns, Johan H M
Clinical studies are often facing missing data. Data can be missing for various reasons, for example, patients moved, certain measurements are only administered in high-risk groups, and patients are unable to attend clinic because of their health status. There are various ways to handle these missing data (e.g., complete cases analyses, mean substitution). Each of these techniques potentially influences both the analyses and the results of a study. The first aim of this structured review was to analyze how often researchers in the field of otorhinolaryngology/head & neck surgery report missing data. The second aim was to systematically describe how researchers handle missing data in their analyses. The third aim was to provide a solution on how to deal with missing data by means of the multiple imputation technique. With this review, we aim to contribute to a higher quality of reporting in otorhinolaryngology research. Clinical studies among the 398 most recently published research articles in three major journals in the field of otorhinolaryngology/head & neck surgery were analyzed based on how researchers reported and handled missing data. Of the 316 clinical studies, 85 studies reported some form of missing data. Of those 85, only a small number (12 studies, 3.8%) actively handled the missingness in their data. The majority of researchers exclude incomplete cases, which results in biased outcomes and a drop in statistical power. Within otorhinolaryngology research, missing data are largely ignored and underreported, and consequently, handled inadequately. This has major impact on the results and conclusions drawn from this research. Based on the outcomes of this review, we provide solutions on how to deal with missing data. To illustrate, we clarify the use of multiple imputation techniques, which recently became widely available in standard statistical programs.
NASA Technical Reports Server (NTRS)
Hudson, Nicolas; Lin, Ying; Barengoltz, Jack
2010-01-01
A method for evaluating the probability of a Viable Earth Microorganism (VEM) contaminating a sample during the sample acquisition and handling (SAH) process of a potential future Mars Sample Return mission is developed. A scenario where multiple core samples would be acquired using a rotary percussive coring tool, deployed from an arm on a MER class rover is analyzed. The analysis is conducted in a structured way by decomposing sample acquisition and handling process into a series of discrete time steps, and breaking the physical system into a set of relevant components. At each discrete time step, two key functions are defined: The probability of a VEM being released from each component, and the transport matrix, which represents the probability of VEM transport from one component to another. By defining the expected the number of VEMs on each component at the start of the sampling process, these decompositions allow the expected number of VEMs on each component at each sampling step to be represented as a Markov chain. This formalism provides a rigorous mathematical framework in which to analyze the probability of a VEM entering the sample chain, as well as making the analysis tractable by breaking the process down into small analyzable steps.
Planning and supervision of reactor defueling using discrete event techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garcia, H.E.; Imel, G.R.; Houshyar, A.
1995-12-31
New fuel handling and conditioning activities for the defueling of the Experimental Breeder Reactor II are being performed at Argonne National Laboratory. Research is being conducted to investigate the use of discrete event simulation, analysis, and optimization techniques to plan, supervise, and perform these activities in such a way that productivity can be improved. The central idea is to characterize this defueling operation as a collection of interconnected serving cells, and then apply operational research techniques to identify appropriate planning schedules for given scenarios. In addition, a supervisory system is being developed to provide personnel with on-line information on themore » progress of fueling tasks and to suggest courses of action to accommodate changing operational conditions. This paper provides an introduction to the research in progress at ANL. In particular, it briefly describes the fuel handling configuration for reactor defueling at ANL, presenting the flow of material from the reactor grid to the interim storage location, and the expected contributions of this work. As an example of the studies being conducted for planning and supervision of fuel handling activities at ANL, an application of discrete event simulation techniques to evaluate different fuel cask transfer strategies is given at the end of the paper.« less
NASA Technical Reports Server (NTRS)
Hennrich, C. W.; Konrath, E. J., Jr.
1973-01-01
A basic automated substructure analysis capability for NASTRAN is presented which eliminates most of the logistical data handling and generation chores that are currently associated with the method. Rigid formats are proposed which will accomplish this using three new modules, all of which can be added to level 16 with a relatively small effort.
NASA Technical Reports Server (NTRS)
Billingsley, F.
1982-01-01
Concerns are expressed about the data handling aspects of system design and about enabling technology for data handling and data analysis. The status, contributing factors, critical issues, and recommendations for investigations are listed for data handling, rectification and registration, and information extraction. Potential supports to individual P.I., research tasks, systematic data system design, and to system operation. The need for an airborne spectrometer class instrument for fundamental research in high spectral and spatial resolution is indicated. Geographic information system formatting and labelling techniques, very large scale integration, and methods for providing multitype data sets must also be developed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhong, Lirong; Mitroshkov, Alexandre V.; Gilmore, Tyler J.
The Bioenergy Program at Pacific Northwest National Laboratory (PNNL) is evaluating the feasibility of converting wastewater sludge materials to fuels. Wastewater sludge from various municipalities will be used in the evaluation process and as with any municipal waste, there is the potential for residual contaminates to remain in the sludge following wastewater treatment. Many surveys and studies have confirmed the presence of pharmaceuticals in municipal wastewater and effluents (World Health Organization, 2011). Determination of the presence and concentrations of the contaminants is required to define the proper handling of this sludge. A list of targeted compounds was acquired from themore » literature and an analytical method was developed for the pharmaceutical and personal care compounds. The presence of organics complicated the analytical techniques and, in some cases, the precision of the results. However, residual concentrations of a range of compounds were detected in the wastewater sludge and the presence and concentrations of these compounds will be considered in identifying the appropriate handling of this material in conduct of research.« less
Laser etching of austenitic stainless steels for micro-structural evaluation
NASA Astrophysics Data System (ADS)
Baghra, Chetan; Kumar, Aniruddha; Sathe, D. B.; Bhatt, R. B.; Behere, P. G.; Afzal, Mohd
2015-06-01
Etching is a key step in metallography to reveal microstructure of polished specimen under an optical microscope. A conventional technique for producing micro-structural contrast is chemical etching. As an alternate, laser etching is investigated since it does not involve use of corrosive reagents and it can be carried out without any physical contact with sample. Laser induced etching technique will be beneficial especially in nuclear industry where materials, being radioactive in nature, are handled inside a glove box. In this paper, experimental results of pulsed Nd-YAG laser based etching of few austenitic stainless steels such as SS 304, SS 316 LN and SS alloy D9 which are chosen as structural material for fabrication of various components of upcoming Prototype Fast Breeder Reactor (PFBR) at Kalpakkam India were reported. Laser etching was done by irradiating samples using nanosecond pulsed Nd-YAG laser beam which was transported into glass paneled glove box using optics. Experiments were carried out to understand effect of laser beam parameters such as wavelength, fluence, pulse repetition rate and number of exposures required for etching of austenitic stainless steel samples. Laser etching of PFBR fuel tube and plug welded joint was also carried to evaluate base metal grain size, depth of fusion at welded joint and heat affected zone in the base metal. Experimental results demonstrated that pulsed Nd-YAG laser etching is a fast and effortless technique which can be effectively employed for non-contact remote etching of austenitic stainless steels for micro-structural evaluation.
Handling unfamiliar seeds or how not to destroy your seed sample
Kristina F. Connor; Nathan Schiff
2004-01-01
Beginning work on seeds of endangered and exotic species often means starting with little or no knowledge and working toward successful handling and storage. It is often found that, in the past, exotic or poisonous plants (such as poison ivy) have been regarded as high in nuisance value and low in usefulness. Thus little research has been done on the care and handling...
Long-term pavement performance project laboratory materials testing and handling guide
DOT National Transportation Integrated Search
2007-09-01
The Long Term Pavement Performance (LTPP) Laboratory Material Testing Guide was originally prepared for laboratory material handling and testing of material specimens and samples of asphalt materials, portland cement concrete, aggregates, and soils u...
The ExoMars Sample Preparation and Distribution System
NASA Astrophysics Data System (ADS)
Schulte, Wolfgang; Hofmann, Peter; Baglioni, Pietro; Richter, Lutz; Redlich, . Daniel; Notarnicola, Marco; Durrant, Stephen
2012-07-01
The Sample Preparation and Distribution System (SPDS) is a key element of the ESA ExoMars Rover. It is a set of complex mechanisms designed to receive Mars soil samples acquired from the subsurface with a drill, to crush them and to distribute the obtained soil powder to the scientific instruments of the `Pasteur Payload', in the Rover Analytical Laboratory (ALD). In particular, the SPDS consists of: (1) a Core Sample Handling System (CSHS), including a Core Sample Transportation Mechanism (CSTM) and a Blank Sample Dispenser; (2) a Crushing Station (CS); (3) a Powder Sample Dosing and Distribution System (PSDDS); and (4) a Powder Sample Handling System (PSHS) which is a carousel carrying pyrolysis ovens, a re-fillable sample container and a tool to flatten the powder sample surface. Kayser-Threde has developed, undercontract with the ExoMars prime contractor Thales Alenia Space Italy, breadboards and an engineering model of the SPDS mechanisms. Tests of individual mechanisms, namely the CSTM, CS and PSDDS were conducted both in laboratory ambient conditions and in a simulated Mars environment, using dedicated facilities. The SPDS functionalities and performances were measured and evaluated. In the course of 2011 the SPDS Dosing Station (part of the PSDDS) was also tested in simulated Mars gravity conditions during a parabolic flight campaign. By the time of the conference, an elegant breadboard of the Powder Sample Handling System will have been built and tested. The next step, planned by mid of 2012, will be a complete end-to-end test of the sample handling and processing chain, combining all four SPDS mechanisms. The possibility to verify interface and operational aspects between the SPDS and the ALD scientific instruments using the available instruments breadboards with the end-to-end set-up is currently being evaluated. This paper illustrates the most recent design status of the SPDS mechanisms, summarizes the test results and highlights future development activities, including potential involvement of the ExoMars science experiments.
Microbiological quality and safe handling of enteral diets in a hospital in Minas Gerais, Brazil
Pinto, Raquel Oliveira Medrado; Correia, Eliznara Fernades; Pereira, Keyla Carvalho; Costa, Paulo de Souza; da Silva, Daniele Ferreira
2015-01-01
Contamination of enteral diets represents a high risk of compromising the patient's medical condition. To assess the microbiological quality and aseptic conditions in the preparation and administration of handmade and industrialized enteral diets offered in a hospital in the Valley of Jequitinhonha, MG, Brazil, we performed a microbiological analysis of 50 samples of diets and 27 samples of surfaces, utensils, and water used in the preparation of the diets. In addition, we assessed the good handling practices of enteral diets according to the requirements specified by the Brazilian legislation. Both kinds of enteral diets showed contamination by coliforms and Pseudomonas spp. No sample was positive for Staphylococcus aureus and Salmonella spp. On the other hand, Listeria spp. was detected in only one sample of handmade diets. Contamination was significantly higher in the handmade preparations (p < 0.05). Nonconformities were detected with respect to good handling practices, which may compromise the diet safety. The results indicate that the sanitary quality of the enteral diets is unsatisfactory, especially handmade diets. Contamination by Pseudomonas spp. is significant because it is often involved in infection episodes. With regard to aseptic practices, it was observed the need of implementing new procedures for handling enteral diets. PMID:26273278
Aquino-Pérez, Dulce María; Peña-Cadena, Daniel; Trujillo-García, José Ubaldo; Jiménez-Sandoval, Jaime Omar; Machorro-Muñoz, Olga Stephanie
2013-01-01
The use of metered dose inhaler (MDI) is key in the treatment of asthma; its effectiveness is related to proper technique. The purpose of this study is to evaluate the use of the technique of metered dose inhalers for the parents or guardians of school children with asthma. In this cross-sectional study, we used a sample of 221 individual caregivers (parent or guardian) of asthmatic children from 5 to 12 years old, who use MDI. We designed a validated questionnaire consisting of 27 items which addressed the handling of inhaler technique. Descriptive statistics was used. Caregivers were rated as "good technique" in 41 fathers (18.6%), 77 mothers (34.8%) and 9 tutors (4.1%), and with a "regular technique" 32 fathers (14.5%), 48 mothers (21.2%) and 14 guardians (6.3%). Asthmatic children aged 9 were rated as with "good technique" in 24 (10.9%). According to gender, we found a "good technique" in 80 boys (36.2%) and 47 girls (21.3%) and with a "regular technique" in 59 boys (26.7%) and 35 girls (15.8%), P 0.0973, RP 0.9. We found with a "regular technique" mainly those asthmatic children diagnosed at ages between 1 to 3 years. Most of the participants had a good technical qualification; however major mistakes were made at key points in the performance of it.
Postdoctoral Fellow | Center for Cancer Research
The Neuro-Oncology Branch (NOB), Center for Cancer Research (CCR), National Cancer Institute (NCI) of the National Institutes of Health (NIH) is seeking outstanding postdoctoral candidates interested in studying the metabolic changes in brain tumors such as glioblastoma multiforme (GBMs). NOB’s Metabolomics program is interested in revealing the metabolic alterations of isocitrate dehydrogenase (IDH1)-mutated GBMs and in exploiting these deregulations for therapeutic applications. A combination of methods such as molecular biology, animal models, as well as in vitro and in vivo metabolomics using Raman Imaging Microscopy, Nuclear Magnetic Resonance spectroscopy (NMR), Mass Spectrometry (MS) and Magnetic Resonance Imaging (MRI) techniques are employed. The position will specifically focus on molecular biology and Raman Imaging Microscopy, which includes work in Western Blotting, mammalian cell culture and other common biomedical techniques used in cancer bio logy labs such as handling tissue samples, preparing tissue slides, staining, and extracting proteins from brain tissue.
Nanoliter-Scale Protein Crystallization and Screening with a Microfluidic Droplet Robot
Zhu, Ying; Zhu, Li-Na; Guo, Rui; Cui, Heng-Jun; Ye, Sheng; Fang, Qun
2014-01-01
Large-scale screening of hundreds or even thousands of crystallization conditions while with low sample consumption is in urgent need, in current structural biology research. Here we describe a fully-automated droplet robot for nanoliter-scale crystallization screening that combines the advantages of both automated robotics technique for protein crystallization screening and the droplet-based microfluidic technique. A semi-contact dispensing method was developed to achieve flexible, programmable and reliable liquid-handling operations for nanoliter-scale protein crystallization experiments. We applied the droplet robot in large-scale screening of crystallization conditions of five soluble proteins and one membrane protein with 35–96 different crystallization conditions, study of volume effects on protein crystallization, and determination of phase diagrams of two proteins. The volume for each droplet reactor is only ca. 4–8 nL. The protein consumption significantly reduces 50–500 fold compared with current crystallization stations. PMID:24854085
Nanoliter-scale protein crystallization and screening with a microfluidic droplet robot.
Zhu, Ying; Zhu, Li-Na; Guo, Rui; Cui, Heng-Jun; Ye, Sheng; Fang, Qun
2014-05-23
Large-scale screening of hundreds or even thousands of crystallization conditions while with low sample consumption is in urgent need, in current structural biology research. Here we describe a fully-automated droplet robot for nanoliter-scale crystallization screening that combines the advantages of both automated robotics technique for protein crystallization screening and the droplet-based microfluidic technique. A semi-contact dispensing method was developed to achieve flexible, programmable and reliable liquid-handling operations for nanoliter-scale protein crystallization experiments. We applied the droplet robot in large-scale screening of crystallization conditions of five soluble proteins and one membrane protein with 35-96 different crystallization conditions, study of volume effects on protein crystallization, and determination of phase diagrams of two proteins. The volume for each droplet reactor is only ca. 4-8 nL. The protein consumption significantly reduces 50-500 fold compared with current crystallization stations.
Optics-Integrated Microfluidic Platforms for Biomolecular Analyses
Bates, Kathleen E.; Lu, Hang
2016-01-01
Compared with conventional optical methods, optics implemented on microfluidic chips provide small, and often much cheaper ways to interrogate biological systems from the level of single molecules up to small model organisms. The optical probing of single molecules has been used to investigate the mechanical properties of individual biological molecules; however, multiplexing of these measurements through microfluidics and nanofluidics confers many analytical advantages. Optics-integrated microfluidic systems can significantly simplify sample processing and allow a more user-friendly experience; alignments of on-chip optical components are predetermined during fabrication and many purely optical techniques are passively controlled. Furthermore, sample loss from complicated preparation and fluid transfer steps can be virtually eliminated, a particularly important attribute for biological molecules at very low concentrations. Excellent fluid handling and high surface area/volume ratios also contribute to faster detection times for low abundance molecules in small sample volumes. Although integration of optical systems with classical microfluidic analysis techniques has been limited, microfluidics offers a ready platform for interrogation of biophysical properties. By exploiting the ease with which fluids and particles can be precisely and dynamically controlled in microfluidic devices, optical sensors capable of unique imaging modes, single molecule manipulation, and detection of minute changes in concentration of an analyte are possible. PMID:27119629
Elliott, D.G.; Barila, T.Y.
1987-01-01
We developed a rapid method for detecting and quantifying the pathogen Renibacterium salmoninarum in coelomic fluid of spring chinook salmon (Oncorhynchus tshawytscha) by concentrating the bacteria on 0.2-μm polycarbonate filters and staining them with specific fluorescein-labeled antibody. Centrifugation of samples and resuspension of the sedimented material in phosphate-buffered saline containing Triton X-100 increased the ease of filtration. Background fluorescence was reduced by counterstaining filters with Eriochrome black T. Postfiltration staining, rinsing, and counterstaining were done in the syringe-mounted filter holders, reducing handling of the filters and possible loss of bacteria. The number of bacteria detected by the filtration – fluorescent antibody technique in a broth culture of R. salmoninarum ranged from 6.7 × 107to7.6 × 107/mL and was slightly higher than that determined by plate count (9.6 × 106/mL). Increasing the sample dilution or decreasing the number of microscope fields examined generally increased the variability of filter counts of R. salmoninarum. Using the filtration – fluorescent antibody technique, we detected the bacterium in the coelomic fluid of 85% of spawning female spring chinook salmon sampled from a hatchery population.
Techniques for tritium recovery from carbon flakes and dust at the JET active gas handling system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gruenhagen, S.; Perevezentsev, A.; Brennan, P. D.
2008-07-15
Detritiation of highly tritium contaminated carbon and metal material used as first wall armour is a key issue for fusion machines like JET and ITER. Re-deposited carbon and hydrogen in the form of flakes and dust can lead to a build-up of the tritium inventory and therefore this material must be removed and processed. The high tritium concentration of the flake and dust material collected from the JET vacuum vessel makes it unsuitable for direct waste disposal without detritiation. A dedicated facility to process the tritiated carbon flake material and recover the tritium has been designed and built. In severalmore » test runs active material was successfully processed and de-tritiated in the new facility. Samples containing only carbon and hydrogen isotopes have been completely oxidized without any residue. Samples containing metallic impurities, e.g. beryllium, require longer processing times, adjusted processing parameters and yield an oxide residue. The detritiation factor was 2x10{sup 4}. In order to simulate in-vessel and ex-vessel detritiation techniques, the detritiation of a carbon flake sample by isotopic exchange in a hydrogen atmosphere was investigated. 2.8% of tritium was recovered by this means. (authors)« less
On the accuracy and reliability of predictions by control-system theory.
Bourbon, W T; Copeland, K E; Dyer, V R; Harman, W K; Mosley, B L
1990-12-01
In three experiments we used control-system theory (CST) to predict the results of tracking tasks on which people held a handle to keep a cursor even with a target on a computer screen. 10 people completed a total of 104 replications of the task. In each experiment, there were two conditions: in one, only the handle affected the position of the cursor; in the other, a random disturbance also affected the cursor. From a person's performance during Condition 1, we derived constants used in the CST model to predict the results of Condition 2. In two experiments, predictions occurred a few minutes before Condition 2; in one experiment, the delay was 1 yr. During a 1-min. experimental run, the positions of handle and cursor, produced by the person, were each sampled 1800 times, once every 1/30 sec. During a modeling run, the model predicted the positions of the handle and target for each of the 1800 intervals sampled in the experimental run. In 104 replications, the mean correlation between predicted and actual positions of the handle was .996; SD = .002.
Microfluidic viscometers for shear rheology of complex fluids and biofluids
Wang, William S.; Vanapalli, Siva A.
2016-01-01
The rich diversity of man-made complex fluids and naturally occurring biofluids is opening up new opportunities for investigating their flow behavior and characterizing their rheological properties. Steady shear viscosity is undoubtedly the most widely characterized material property of these fluids. Although widely adopted, macroscale rheometers are limited by sample volumes, access to high shear rates, hydrodynamic instabilities, and interfacial artifacts. Currently, microfluidic devices are capable of handling low sample volumes, providing precision control of flow and channel geometry, enabling a high degree of multiplexing and automation, and integrating flow visualization and optical techniques. These intrinsic advantages of microfluidics have made it especially suitable for the steady shear rheology of complex fluids. In this paper, we review the use of microfluidics for conducting shear viscometry of complex fluids and biofluids with a focus on viscosity curves as a function of shear rate. We discuss the physical principles underlying different microfluidic viscometers, their unique features and limits of operation. This compilation of technological options will potentially serve in promoting the benefits of microfluidic viscometry along with evincing further interest and research in this area. We intend that this review will aid researchers handling and studying complex fluids in selecting and adopting microfluidic viscometers based on their needs. We conclude with challenges and future directions in microfluidic rheometry of complex fluids and biofluids. PMID:27478521
A powerful and flexible approach to the analysis of RNA sequence count data
Zhou, Yi-Hui; Xia, Kai; Wright, Fred A.
2011-01-01
Motivation: A number of penalization and shrinkage approaches have been proposed for the analysis of microarray gene expression data. Similar techniques are now routinely applied to RNA sequence transcriptional count data, although the value of such shrinkage has not been conclusively established. If penalization is desired, the explicit modeling of mean–variance relationships provides a flexible testing regimen that ‘borrows’ information across genes, while easily incorporating design effects and additional covariates. Results: We describe BBSeq, which incorporates two approaches: (i) a simple beta-binomial generalized linear model, which has not been extensively tested for RNA-Seq data and (ii) an extension of an expression mean–variance modeling approach to RNA-Seq data, involving modeling of the overdispersion as a function of the mean. Our approaches are flexible, allowing for general handling of discrete experimental factors and continuous covariates. We report comparisons with other alternate methods to handle RNA-Seq data. Although penalized methods have advantages for very small sample sizes, the beta-binomial generalized linear model, combined with simple outlier detection and testing approaches, appears to have favorable characteristics in power and flexibility. Availability: An R package containing examples and sample datasets is available at http://www.bios.unc.edu/research/genomic_software/BBSeq Contact: yzhou@bios.unc.edu; fwright@bios.unc.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:21810900
NASA Astrophysics Data System (ADS)
Hou, Ligang; Luo, Rengui; Wu, Wuchen
2006-11-01
This paper forwards a low power grating detection chip (EYAS) on length and angle precision measurement. Traditional grating detection method, such as resister chain divide or phase locked divide circuit are difficult to design and tune. The need of an additional CPU for control and display makes these methods' implementation more complex and costly. Traditional methods also suffer low sampling speed for the complex divide circuit scheme and CPU software compensation. EYAS is an application specific integrated circuit (ASIC). It integrates micro controller unit (MCU), power management unit (PMU), LCD controller, Keyboard interface, grating detection unit and other peripherals. Working at 10MHz, EYAS can afford 5MHz internal sampling rate and can handle 1.25MHz orthogonal signal from grating sensor. With a simple control interface by keyboard, sensor parameter, data processing and system working mode can be configured. Two LCD controllers can adapt to dot array LCD or segment bit LCD, which comprised output interface. PMU alters system between working and standby mode by clock gating technique to save power. EYAS in test mode (system action are more frequently than real world use) consumes 0.9mw, while 0.2mw in real world use. EYAS achieved the whole grating detection system function, high-speed orthogonal signal handling in a single chip with very low power consumption.
Symes, Sally; Goldsmith, Paul; Haines, Heather
2015-07-01
Seed sprouts have been implicated as vehicles for numerous foodborne outbreaks worldwide. Seed sprouts pose a unique food safety concern because of the ease of microbiological seed contamination, the inherent ability of the sprouting process to support microbial growth, and their consumption either raw or lightly cooked. To examine seed sprout safety in the Australian state of Victoria, a survey was conducted to detect specific microbes in seed sprout samples and to investigate food handling practices relating to seed sprouts. A total of 298 seed sprout samples were collected from across 33 local council areas. Escherichia coli was detected in 14.8%, Listeria spp. in 12.3%, and Listeria monocytogenes in 1.3% of samples analyzed. Salmonella spp. were not detected in any of the samples. A range of seed sprout handling practices were identified as potential food safety issues in some food businesses, including temperature control, washing practices, length of storage, and storage in proximity to unpackaged ready-to-eat potentially hazardous foods.
Bruised Poultry Tissue as a Possible Source of Staphylococcal Infection
Roskey, C. T.; Hamdy, M. K.
1972-01-01
Bacteriological analyses were made on 45 swab samples secured from hands of poultry workers on processing line, on 31 bruised and 15 normal poultry tissue samples, and on 15 swabs obtained from infected lacerations and exudates of abcesses on hands, arms, chest, and abdomen of poultry workers. A total of 170 Staphylococcus cultures were isolated from samples examined. These cultures were characterized morphologically and biochemically and then grouped into six distinct patterns. S. aureus was found in 86.6% of swab samples obtained from infected workers, in 40% of swabs from hands of workers who handle bruised birds, and in 38.7% of bruised tissues, and was absent from all samples obtained from hands of workers who do not handle bruised birds. All the coagulase-positive staphylococcal isolates were bacteriophage-typed, and the results showed that the same phage-type S. aureus was found in many poultry bruises and in infected lesions of poultry workers as well as on hands of workers who handle bruised birds. These results indicate that poultry bruises are a source of staphylococcal infection encountered among poultry workers. PMID:4553136
Particle Manipulation Methods in Droplet Microfluidics.
Tenje, Maria; Fornell, Anna; Ohlin, Mathias; Nilsson, Johan
2018-02-06
This Feature describes the different particle manipulation techniques available in the droplet microfluidics toolbox to handle particles encapsulated inside droplets and to manipulate whole droplets. We address the advantages and disadvantages of the different techniques to guide new users.
Coherent communication link using diode-pumped lasers
NASA Technical Reports Server (NTRS)
Kane, Thomas J.; Wallace, Richard W.
1989-01-01
Work toward developing a diffraction limited, single frequency, modulated transmitter suitable for coherent optical communication or direct detection communication is discussed. Diode pumped, monolithic Nd:YAG nonplanar ring oscillators were used as the carrier beam. An external modulation technique which can handle high optical powers, has moderate modulation voltage, and which can reach modulation rates of 1 GHz was invented. Semiconductor laser pumped solid-state lasers which have high output power (0.5 Watt) and which oscillate at a single frequency, in a diffraction limited beam, at the wavelength of 1.06 microns were built. A technique for phase modulating the laser output by 180 degrees with a 40-volt peak to peak driving voltage is demonstrated. This technique can be adapted for amplitude modulation of 100 percent with the same voltage. This technique makes use of a resonant bulk modulator, so it does not have the power handling limitations of guided wave modulators.
Bertol, T M; Ellis, M; Ritter, M J; McKeith, F K
2005-07-01
This study was carried out to evaluate the effect of feed withdrawal and handling intensity on blood acid-base responses and muscle glycolytic potential in slaughter-weight pigs. Sixty crossbred pigs (BW = 107.7 +/- 0.56 kg; 44 barrows and 16 gilts) were used in a randomized complete block design with a 2 x 2 factorial arrangement of treatments: 1) feed withdrawal (0 vs. 24 h), and 2) handling intensity (low vs. high). The high-intensity handling treatment consisted of moving the pigs through a passage (12.2 m long x 0.91 m wide) for eight laps using an electric goad two times per lap. Pigs in the low-intensity handling treatment were moved at their own pace through the passage for eight laps using a livestock panel and paddle. Biopsy samples were collected from the LM at the beginning of feed withdrawal, at the end of the handling procedure, and 4 h after handling. Blood samples were collected 2 h before and immediately after the handling procedure. There were no interactions between feed withdrawal and handling intensity for any of the variables measured. Feed withdrawal decreased (P < 0.05) baseline and posthandling body temperature (38.85 vs. 38.65 degrees C; SEM = 0.060 and 39.70 vs. 39.37 degrees C; SEM = 0.04, respectively) and blood glucose, lowered (P < 0.05) baseline partial pressure of oxygen and partial pressure of carbon dioxide, and increased (P < 0.01) baseline and posthandling plasma free fatty acid concentrations. High-intensity handling produced higher (P < 0.01) posthandling lactate and glucose, and lower (P < 0.01) posthandling blood pH (7.33 vs. 7.18 +/- 0.02, respectively), bicarbonate, base excess, and total carbon dioxide than low-intensity handling. Longissimus muscle glycolytic potential of fasted pigs was lower (P < 0.01) than in fed pigs at the end of the handling procedure (177.2 vs. 137.0 micromol/g of wet tissue; SEM = 10.08, respectively). There was no effect of handling intensity on longissimus muscle glycolytic potential. Feed withdrawal did not attenuate the blood acid-base changes caused by handling; however, the combination of feed withdrawal and handling decreased muscle glycolytic potential.
2013-01-01
Background Capture, handling and chemical restraint are basic techniques often needed for research or management purposes. The aim of this study was testing a combination of tiletamine-zolazepam (TZ) (3 mg/kg) and medetomidine (M) (0.05 mg/kg) on Eurasian wild boar (Sus scrofa). A total of 77 free-ranging wild boar were captured by means of portable cages and corral traps and then anaesthetized with intramuscular darts using a blowpipe. The individual response to chemical immobilization was characterized using anaesthetic, clinical, and serum biochemical variables. After the procedure, 14 of these wild boar were monitored for 20 days using GPS-GSM collars. Results Pre-release mortality during capture and handling (6.5%) was associated with severe trauma in corral traps. Capture specificity for wild boar was 96.3% and trapping effort was 16.5 days per captured wild boar. Mean induction period was 4.5 ± 2.2 min, hypnosis period enabling effective handling was 61.6 ± 25.4 min, and recovery period was 12.8 ± 12.1 min. No heart or respiratory failure due to added stress occurred and post-release monitoring by GPS-devices revealed no mortality due to anaesthesia. According to the best statistical model obtained, the main factor driving anaesthetic efficacy and stress indicators is trap type. Conclusions Both cage and corral traps are efficient methods to capture wild boar. Cage traps are safer, as demonstrated by mortality rates as well as anaesthetic, physiological, and serum biochemical responses. This anaesthetic protocol is useful for prolonged handling of wild boar and allows sampling and collecting data for ecological and epidemiological studies. PMID:23702232
Flight-testing and frequency-domain analysis for rotorcraft handling qualities
NASA Technical Reports Server (NTRS)
Ham, Johnnie A.; Gardner, Charles K.; Tischler, Mark B.
1995-01-01
A demonstration of frequency-domain flight-testing techniques and analysis was performed on a U.S. Army OH-58D helicopter in support of the OH-58D Airworthiness and Flight Characteristics Evaluation and of the Army's development and ongoing review of Aeronautical Design Standard 33C, Handling Qualities Requirements for Military Rotorcraft. Hover and forward flight (60 kn) tests were conducted in 1 flight hour by Army experimental test pilots. Further processing of the hover data generated a complete database of velocity, angular-rate, and acceleration-frequency responses to control inputs. A joint effort was then undertaken by the Airworthiness Qualification Test Dirtectorate and the U.S. Army Aeroflightdynamics Directorate to derive handling-quality information from the frequency-domain database using a variety of approaches. This report documents numerous results that have been obtained from the simple frequency-domain tests; in many areas, these results provide more insight into the aircraft dynmamics that affect handling qualities than do traditional flight tests. The handling-quality results include ADS-33C bandwidth and phase-delay calculations, vibration spectral determinations, transfer-function models to examine single-axis results, and a six-degree-of-freedom fully coupled state-space model. The ability of this model to accurately predict responses was verified using data from pulse inputs. This report also documents the frequency-sweep flight-test technique and data analysis used to support the tests.
Mars Sample Handling Protocol Workshop Series: Workshop 4
NASA Technical Reports Server (NTRS)
Race Margaret S. (Editor); DeVincenzi, Donald L. (Editor); Rummel, John D. (Editor); Acevedo, Sara E. (Editor)
2001-01-01
In preparation for missions to Mars that will involve the return of samples to Earth, it will be necessary to prepare for the receiving, handling, testing, distributing, and archiving of martian materials here on Earth. Previous groups and committees have studied selected aspects of sample return activities, but specific detailed protocols for the handling and testing of returned samples must still be developed. To further refine the requirements for sample hazard testing and to develop the criteria for subsequent release of sample materials from quarantine, the NASA Planetary Protection Officer convened a series of workshops in 2000-2001. The overall objective of the Workshop Series was to produce a Draft Protocol by which returned martian sample materials can be assessed for biological hazards and examined for evidence of life (extant or extinct) while safeguarding the purity of the samples from possible terrestrial contamination. This report also provides a record of the proceedings of Workshop 4, the final Workshop of the Series, which was held in Arlington, Virginia, June 5-7, 2001. During Workshop 4, the sub-groups were provided with a draft of the protocol compiled in May 2001 from the work done at prior Workshops in the Series. Then eight sub-groups were formed to discuss the following assigned topics: Review and Assess the Draft Protocol for Physical/Chemical Testing Review and Assess the Draft Protocol for Life Detection Testing Review and Assess the Draft Protocol for Biohazard Testing Environmental and Health/Monitoring and Safety Issues Requirements of the Draft Protocol for Facilities and Equipment Contingency Planning for Different Outcomes of the Draft Protocol Personnel Management Considerations in Implementation of the Draft Protocol Draft Protocol Implementation Process and Update Concepts This report provides the first complete presentation of the Draft Protocol for Mars Sample Handling to meet planetary protection needs. This Draft Protocol, which was compiled from deliberations and recommendations from earlier Workshops in the Series, represents a consensus that emerged from the discussions of all the sub-groups assembled over the course of the five Workshops of the Series. These discussions converged on a conceptual approach to sample handling, as well as on specific analytical requirements. Discussions also identified important issues requiring attention, as well as research and development needed for protocol implementation.
7 CFR 800.60 - Deceptive actions and practices.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Agriculture Regulations of the Department of Agriculture (Continued) GRAIN INSPECTION, PACKERS AND STOCKYARD ADMINISTRATION (FEDERAL GRAIN INSPECTION SERVICE), DEPARTMENT OF AGRICULTURE GENERAL REGULATIONS Grain Handling... official personnel, any action or practice, including the loading, weighing, handling, or sampling of grain...
Shiratori, Fábio Kenji; Valle, Accácio Lins do; Pegoraro, Thiago Amadei; Carvalho, Ricardo Marins; Pereira, Jefferson Ricardo
2013-07-01
Resin cements are widely used to cement intraradicular posts, but bond strength is significantly influenced by the technique and material used for cementation. The purpose of this study was to evaluate the bond strength of 3 self-adhesive cements used to cement intraradicular glass fiber posts. The cements all required different application and handling techniques. Forty-five human maxillary canines were selected and randomly divided into 3 groups n= 15 by drawing lots: Group BIS - Biscem, Group BRE - Breeze, and Group MAX - Maxcem. Each group was divided into 3 subgroups according to application and handling techniques: Sub-group A - Automix/Point tip applicator, Sub-group L - Handmix/Lentulo, and Sub-group C - Handmix/Centrix. Cementation of the posts was performed according to the manufacturers' instructions. The push-out test was performed with a crosshead speed of 0.5 mm/min, and bond strength was expressed in megapascals. The results were evaluated by 2-way ANOVA and the all pairwise multiple comparison procedures (Tukey test) (α=.05). Breeze cement showed the highest average for the subgroups A, L, and C when compared to the Biscem cement and Maxcem Elite (P<.05). Statistically significant differences among the subgroups were only observed for Biscem. This study shows that application and handling techniques may influence the bond strength of different self-adhesive cements when used for intraradicular post cementation. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
A design procedure for the handling qualities optimization of the X-29A aircraft
NASA Technical Reports Server (NTRS)
Bosworth, John T.; Cox, Timothy H.
1989-01-01
A design technique for handling qualities improvement was developed for the X-29A aircraft. As with any new aircraft, the X-29A control law designers were presented with a relatively high degree of uncertainty in their mathematical models. The presence of uncertainties, and the high level of static instability of the X-29A caused the control law designers to stress stability and robustness over handling qualities. During flight test, the mathematical models of the vehicle were validated or corrected to match the vehicle dynamic behavior. The updated models were then used to fine tune the control system to provide fighter-like handling characteristics. A design methodology was developed which works within the existing control system architecture to provide improved handling qualities and acceptable stability with a minimum of cost in both implementation as well as software verification and validation.
Sampling and data handling methods for inhalable particulate sampling. Final report nov 78-dec 80
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, W.B.; Cushing, K.M.; Johnson, J.W.
1982-05-01
The report reviews the objectives of a research program on sampling and measuring particles in the inhalable particulate (IP) size range in emissions from stationary sources, and describes methods and equipment required. A computer technique was developed to analyze data on particle-size distributions of samples taken with cascade impactors from industrial process streams. Research in sampling systems for IP matter included concepts for maintaining isokinetic sampling conditions, necessary for representative sampling of the larger particles, while flowrates in the particle-sizing device were constant. Laboratory studies were conducted to develop suitable IP sampling systems with overall cut diameters of 15 micrometersmore » and conforming to a specified collection efficiency curve. Collection efficiencies were similarly measured for a horizontal elutriator. Design parameters were calculated for horizontal elutriators to be used with impactors, the EPA SASS train, and the EPA FAS train. Two cyclone systems were designed and evaluated. Tests on an Andersen Size Selective Inlet, a 15-micrometer precollector for high-volume samplers, showed its performance to be with the proposed limits for IP samplers. A stack sampling system was designed in which the aerosol is diluted in flow patterns and with mixing times simulating those in stack plumes.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilbert, Richard O.
The application of statistics to environmental pollution monitoring studies requires a knowledge of statistical analysis methods particularly well suited to pollution data. This book fills that need by providing sampling plans, statistical tests, parameter estimation procedure techniques, and references to pertinent publications. Most of the statistical techniques are relatively simple, and examples, exercises, and case studies are provided to illustrate procedures. The book is logically divided into three parts. Chapters 1, 2, and 3 are introductory chapters. Chapters 4 through 10 discuss field sampling designs and Chapters 11 through 18 deal with a broad range of statistical analysis procedures. Somemore » statistical techniques given here are not commonly seen in statistics book. For example, see methods for handling correlated data (Sections 4.5 and 11.12), for detecting hot spots (Chapter 10), and for estimating a confidence interval for the mean of a lognormal distribution (Section 13.2). Also, Appendix B lists a computer code that estimates and tests for trends over time at one or more monitoring stations using nonparametric methods (Chapters 16 and 17). Unfortunately, some important topics could not be included because of their complexity and the need to limit the length of the book. For example, only brief mention could be made of time series analysis using Box-Jenkins methods and of kriging techniques for estimating spatial and spatial-time patterns of pollution, although multiple references on these topics are provided. Also, no discussion of methods for assessing risks from environmental pollution could be included.« less
Handling and analysis of ices in cryostats and glove boxes in view of cometary samples
NASA Technical Reports Server (NTRS)
Roessler, K.; Eich, G.; Heyl, M.; Kochan, H.; Oehler, A.; Patnaik, A.; Schlosser, W.; Schulz, R.
1989-01-01
Comet nucleus sample return mission and other return missions from planets and satellites need equipment for handling and analysis of icy samples at low temperatures under vacuum or protective gas. Two methods are reported which were developed for analysis of small icy samples and which are modified for larger samples in cometary matter simulation experiments (KOSI). A conventional optical cryostat system was modified to allow for transport of samples at 5 K, ion beam irradiation, and measurement in an off-line optical spectrophotometer. The new system consists of a removable window plug containing nozzles for condensation of water and volatiles onto a cold finger. This plug can be removed in a vacuum system, changed against another plug (e.g., with other windows (IR, VIS, VUV) or other nozzles). While open, the samples can be treated under vacuum with cooling by manipulators (cut, removal, sample taking, irradiation with light, photons, or ions). After bringing the plug back, the samples can be moved to another site of analysis. For handling the 30 cm diameter mineral-ice samples from the KOSI experiments an 80x80x80 cm glove box made out of plexiglass was used. The samples were kept in a liquid nitrogen bath, which was filled from the outside. A stream a dry N2 and evaporating gas from the bath purified the glove box from impurity gases and, in particular, H2O, which otherwise would condense onto the samples.
Development of analysis techniques for remote sensing of vegetation resources
NASA Technical Reports Server (NTRS)
Draeger, W. C.
1972-01-01
Various data handling and analysis techniques are summarized for evaluation of ERTS-A and supporting high flight imagery. These evaluations are concerned with remote sensors applied to wildland and agricultural vegetation resource inventory problems. Monitoring California's annual grassland, automatic texture analysis, agricultural ground data collection techniques, and spectral measurements are included.
On the Relationship between Technique and Style: The Case of the Violin
ERIC Educational Resources Information Center
Johansson, Mats
2015-01-01
This article examines the formative interaction between instrumental technique and musical style by analysing different approaches to the violin/fiddle. It is argued that technique is constitutive of style and that musical concepts are intimately related to the accumulated experience of sensations associated with handling the instrument in a…
Abel inversion using fast Fourier transforms.
Kalal, M; Nugent, K A
1988-05-15
A fast Fourier transform based Abel inversion technique is proposed. The method is faster than previously used techniques, potentially very accurate (even for a relatively small number of points), and capable of handling large data sets. The technique is discussed in the context of its use with 2-D digital interferogram analysis algorithms. Several examples are given.
Communications techniques and equipment: A compilation
NASA Technical Reports Server (NTRS)
1975-01-01
This Compilation is devoted to equipment and techniques in the field of communications. It contains three sections. One section is on telemetry, including articles on radar and antennas. The second section describes techniques and equipment for coding and handling data. The third and final section includes descriptions of amplifiers, receivers, and other communications subsystems.
Flow-through Fourier transform infrared sensor for total hydrocarbons determination in water.
Pérez-Palacios, David; Armenta, Sergio; Lendl, Bernhard
2009-09-01
A new flow-through Fourier transform infrared (FT-IR) sensor for oil in water analysis based on solid-phase spectroscopy on octadecyl (C18) silica particles has been developed. The C18 non-polar sorbent is placed inside the sensor and is able to retain hydrocarbons from water samples. The system does not require the use of chlorinated solvents, reducing the environmental impact, and the minimal sample handling stages serve to ensure sample integrity whilst reducing exposure of the analyst to any toxic hydrocarbons present within the samples. Fourier transform infrared (FT-IR) spectra were recorded by co-adding 32 scans at a resolution of 4 cm(-1) and the band located at 1462 cm(-1) due to the CH(2) bending was integrated from 1475 to 1450 cm(-1) using a baseline correction established between 1485 and 1440 cm(-1) using the areas as analytical signal. The technique, which provides a limit of detection (LOD) of 22 mg L(-1) and a precision expressed as relative standard deviation (RSD) lower than 5%, is considerably rapid and allows for a high level of automation.
Aircraft model prototypes which have specified handling-quality time histories
NASA Technical Reports Server (NTRS)
Johnson, S. H.
1978-01-01
Several techniques for obtaining linear constant-coefficient airplane models from specified handling-quality time histories are discussed. The pseudodata method solves the basic problem, yields specified eigenvalues, and accommodates state-variable transfer-function zero suppression. The algebraic equations to be solved are bilinear, at worst. The disadvantages are reduced generality and no assurance that the resulting model will be airplane like in detail. The method is fully illustrated for a fourth-order stability-axis small motion model with three lateral handling quality time histories specified. The FORTRAN program which obtains and verifies the model is included and fully documented.
Hapfty, J.; Riley, L.B.
1968-01-01
A method is described for the determination of palladium down to 4ppb (parts per billion, 109), platinum down to 10 ppb and rhodium down to 5 ppb in 15 g of sample. Fire-assay techniques are used to preconcentrate the platinum metals into a gold bead, then the bead is dissolved in aqua regia and diluted to volume with 1M hydrochloric acid. The solution is analysed by optical emission spectrography of the residue from 200 ??l of it evaporated on a pair of flat-top graphite electrodes. This method requires much less sample handling than most published methods for these elements. Data are presented for G-1, W-1, and six new standard rocks of the U.S. Geological Survey. The values for palladium in W-1 are in reasonable agreement with previously published data. ?? 1968.
ADVANCING SITE CHARACTERIZATION AND MONITORING ...
There is no astract available for htis product. If further information is requested, please refer to the bibliogaphic citation and contact the person listed under Contract field. The overall objective of this task is to provide the Agency with improved state-of-the-science guidance, strategies, and techniques to more accurately and effectively collect environmental samples. Under this umbrella objective, research is being conducted to: (a) reduce/minimize the loss of VOCs during sample collection, handling, and preservation, (b) collect undisturbed surface sediments so that the effects of recent depositional events (e.g., flooding or dredging) can clearly be delineated as to their influence on the contamination concentrations present downstream (or where the sediments are deposited), and (c) to determine an effective method to effectively and efficiently separate asbestos in soils from the rest of the soil matrix while maintaining the integrity (i.e, no fiber size reduction) of the asbestos fibers.
Control technology for Richard Klinger, Inc. , Sidney, Ohio. Indepth survey report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heitbrink, W.A.
1984-06-25
Environmental and breathing zone samples were analyzed for asbestos (1332214) at Richard Klinger Incorporated (SIC-3069), Sidney, Ohio in August 1983 as part of an in depth study of dust control during bag opening, dumping, and disposal. Asbestos control technology was inspected. Control of asbestos at the facility was achieved by using an automatic cleaner to clean spills and routinely remove settled and spilled asbestos from the floor. During periods of peak exposure, workers wore NIOSH approved respirators and disposable coveralls. Air sampling was used to identify any asbestos control problems. Closed bales of asbestos were torn. The author concludes thatmore » operation of the bag slitter does not increase asbestos concentrations. Closed bales of asbestos may be an emission source. Improving the quality of the wrapping around the bales and handling techniques during shipment are recommended.« less
Characterization of desert sand as a sensible thermal energy storage medium
NASA Astrophysics Data System (ADS)
Diago, Miguel; Iniesta, Alberto Crespo; Delclos, Thomas; Soum-Glaude, Audrey; Shamim, Tariq; Calvet, Nicolas
2016-05-01
Desert sand from the United Arab Emirates (UAE) is considered as a possible sensible heat, thermal energy storage (TES) material. Its thermal stability, specific heat capacity and tendency to agglomerate are studied at high temperatures. The analyses show that it is possible to use desert sand as a TES material up to 800-1000 °C. Above 800 °C, weak agglomeration effects start to become significant. The samples become solid above 1000 °C. This may represent a major operating limit depending on the handling mechanism in place for the possible transport of the sand. The sand chemical composition is analyzed with the XRF and XRD techniques, which reveal the dominance of quartz and carbonates. Finally, the spectral absorptivity of the samples is measured before and after a thermal cycle, as it may be possible to use the desert sand not only as a TES material but also as a direct solar absorber.
Automation in high-content flow cytometry screening.
Naumann, U; Wand, M P
2009-09-01
High-content flow cytometric screening (FC-HCS) is a 21st Century technology that combines robotic fluid handling, flow cytometric instrumentation, and bioinformatics software, so that relatively large numbers of flow cytometric samples can be processed and analysed in a short period of time. We revisit a recent application of FC-HCS to the problem of cellular signature definition for acute graft-versus-host-disease. Our focus is on automation of the data processing steps using recent advances in statistical methodology. We demonstrate that effective results, on par with those obtained via manual processing, can be achieved using our automatic techniques. Such automation of FC-HCS has the potential to drastically improve diagnosis and biomarker identification.
APIC position paper: safe injection, infusion, and medication vial practices in health care.
Dolan, Susan A; Felizardo, Gwenda; Barnes, Sue; Cox, Tracy R; Patrick, Marcia; Ward, Katherine S; Arias, Kathleen Meehan
2010-04-01
Outbreaks involving the transmission of bloodborne pathogens or other microbial pathogens to patients in various types of health care settings due to unsafe injection, infusion, and medication vial practices are unacceptable. Each of the outbreaks could have been prevented by the use of proper aseptic technique in conjunction with basic infection prevention practices for handling parenteral medications, administration of injections, and procurement and sampling of blood. This document provides practice guidance for health care facilities on essential safe injection, infusion, and vial practices that should be consistently implemented in such settings. 2010 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Paradis, Paul-François; Ishikawa, Takehiko
2005-07-01
Electrostatic levitation and multi-beam radiative heating overcame contamination and sample position instability problems associated with handling of liquid alumina. This allowed the measurements of the surface tension and viscosity in the superheated and undercooled states using the oscillation drop method. Over the 2190-2500 K interval, the surface tension of alumina was measured as σ(T)=0.64--8.2× 10-5 (T-Tm) (N/m), where Tm, the melting temperature, is 2327 K. Similarly, on the same temperature range, the viscosity was determined as η(T)=3.2\\exp[43.2× 103/(RT)] (mPa\\cdots). Both sets of data agree well with the literature values.
Hedmer, Maria; Ludvigsson, Linus; Isaxon, Christina; Nilsson, Patrik T; Skaug, Vidar; Bohgard, Mats; Pagels, Joakim H; Messing, Maria E; Tinnerberg, Håkan
2015-08-01
The industrial use of novel-manufactured nanomaterials such as carbon nanotubes and carbon nanodiscs is increasing globally. Occupational exposure can occur during production, downstream use, and disposal. The health effects of many nanomaterials are not yet fully characterized and to handle nano-objects, their aggregates and agglomerates >100nm (NOAA), a high degree of control measures and personal protective equipment are required. The emission of airborne NOAA during production and handling can contaminate workplace surfaces with dust, which can be resuspended resulting in secondary inhalation exposures and dermal exposures. This study surveys the presence of carbon-based nanomaterials, such as multi-walled carbon nanotubes (MWCNTs) and carbon nanodiscs, as surface contamination at a small-scale producer using a novel tape sampling method. Eighteen different surfaces at a small-scale producer were sampled with an adhesive tape sampling method. The surfaces selected were associated with the production and handling of MWCNT powder in the near-field zone. Surfaces in the far-field zone were also sampled. In addition, tape stripping of the skin was performed on one worker. The tape samples were analysed with scanning electron microscopy to detect the carbon-based NOAA. Air sampling with a personal impactor was also performed on a worker who was producing MWCNTs the same day as the tape samples were collected. MWCNTs were detected in 50% of the collected tape samples and carbon nanodiscs in 17%. MWCNTs and carbon nanodiscs were identified in all parts of the workplace, thus, increasing the risk for secondary inhalation and dermal exposure of the workers. Both airborne MWCNTs and carbon nanodiscs were detected in the personal impactor samples. The tape-strip samples from the worker showed no presence of carbon-containing nanoparticles. Tape sampling is a functional method for detecting surface contamination of carbon-based NOAA and for exposure control during production at potentially any workplace that produces or handles such manufactured nanomaterials. With the tape method, it is possible to monitor if a potential for secondary inhalation exposure or dermal exposure exists through resuspension of dust deposited on workplace surfaces. By means of air sampling, we could confirm that carbon nanodiscs were resuspended into the air at the workplace even though they were not handled during that particular work shift. MWCNTs were detected in the air samples, but can have been derived from either resuspension or from the work tasks with MWCNTs that were performed during the air sampling. Tape sampling is a complementary method to air sampling and together these two methods provide a better view of the hygienic situation in workplaces where NOAA can be emitted into work environments. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Mars Sample Handling Protocol Workshop Series
NASA Technical Reports Server (NTRS)
Rummel, John D. (Editor); Race, Margaret S. (Editor); Acevedo, Sara (Technical Monitor)
2000-01-01
This document is the report resulting from the first workshop of the series on development of the criteria for a Mars sample handling protocol. Workshop 1 was held in Bethesda, Maryland on March 20-22, 2000. This report serves to document the proceedings of Workshop 1; it summarizes relevant background information, provides an overview of the deliberations to date, and helps frame issues that will need further attention or resolution in upcoming workshops. Specific recommendations are not part of this report.
NASA Technical Reports Server (NTRS)
1980-01-01
General Metal Works' Accu-Vol is a high-volume air sampling system used by many government agencies to monitor air quality for pollution control purposes. Procedure prevents possible test-invalidating contamination from materials other than particulate pollutants, caused by manual handling or penetration of windblown matter during transit, a cassette was developed in which the filter is sealed within a metal frame and protected in transit by a snap-on aluminum cover, thus handled only under clean conditions in the laboratory.
Lima, Maria Lúcia Pereira; Negrão, João Alberto; de Paz, Claudia Cristina Paro; Grandin, Temple
2018-03-01
Inadequate corral facilities and improper handling are major causes of stress in beef cattle. The purpose of this study was to evaluate the effects of minor changes in the corral and adoption of good handling practices on the behavior, cortisol release, and time spent taking blood samples in Nellore cows. Minor corral changes included obstructing the cow's vision when the handler walked deep into the animal's flight zone and the elimination of bright objects, color contrasts, puddles, shadows, and darkness in the corral. Handling was improved by eliminating dogs, electric goads (prods), and yelling, as well as adopting a calm behavior. A total of 141 Nellore cows from two typical extensive livestock farms were studied. The cows were evaluated individually before and after the corral changes. Blood samples were collected in the restraint device for cortisol measurement. The minor corral changes and the adoption of good handling practices result in better results for all variables studied. The results showed differences in the interactions between treatment and ranch for chute score (P = 0.0091) and exit score (P < 0.0001). The cortisol release was lower (P < 0.001) and better for the improved methods, resulting in calmer cows compared to cortisol released before the minor changes (41.03 ± 2.9 vs 60.40 ± 3.8 ng/mL). Minor changes made in the corrals and the adoption of good handling practices were effective in improving cow behavior in the chute and in reducing exit velocity, cortisol released, and the time spent taking blood samples.
Sample handling for mass spectrometric proteomic investigations of human sera.
West-Nielsen, Mikkel; Høgdall, Estrid V; Marchiori, Elena; Høgdall, Claus K; Schou, Christian; Heegaard, Niels H H
2005-08-15
Proteomic investigations of sera are potentially of value for diagnosis, prognosis, choice of therapy, and disease activity assessment by virtue of discovering new biomarkers and biomarker patterns. Much debate focuses on the biological relevance and the need for identification of such biomarkers while less effort has been invested in devising standard procedures for sample preparation and storage in relation to model building based on complex sets of mass spectrometric (MS) data. Thus, development of standardized methods for collection and storage of patient samples together with standards for transportation and handling of samples are needed. This requires knowledge about how sample processing affects MS-based proteome analyses and thereby how nonbiological biased classification errors are avoided. In this study, we characterize the effects of sample handling, including clotting conditions, storage temperature, storage time, and freeze/thaw cycles, on MS-based proteomics of human serum by using principal components analysis, support vector machine learning, and clustering methods based on genetic algorithms as class modeling and prediction methods. Using spiking to artificially create differentiable sample groups, this integrated approach yields data that--even when working with sample groups that differ more than may be expected in biological studies--clearly demonstrate the need for comparable sampling conditions for samples used for modeling and for the samples that are going into the test set group. Also, the study emphasizes the difference between class prediction and class comparison studies as well as the advantages and disadvantages of different modeling methods.
Brooks, M.H.; Schroder, L.J.; Willoughby, T.C.
1987-01-01
The U.S. Geological Survey operated a blind audit sample program during 1974 to test the effects of the sample handling and shipping procedures used by the National Atmospheric Deposition Program and National Trends Network on the quality of wet deposition data produced by the combined networks. Blind audit samples, which were dilutions of standard reference water samples, were submitted by network site operators to the central analytical laboratory disguised as actual wet deposition samples. Results from the analyses of blind audit samples were used to calculate estimates of analyte bias associated with all network wet deposition samples analyzed in 1984 and to estimate analyte precision. Concentration differences between double blind samples that were submitted to the central analytical laboratory and separate analyses of aliquots of those blind audit samples that had not undergone network sample handling and shipping were used to calculate analyte masses that apparently were added to each blind audit sample by routine network handling and shipping procedures. These calculated masses indicated statistically significant biases for magnesium, sodium , potassium, chloride, and sulfate. Median calculated masses were 41.4 micrograms (ug) for calcium, 14.9 ug for magnesium, 23.3 ug for sodium, 0.7 ug for potassium, 16.5 ug for chloride and 55.3 ug for sulfate. Analyte precision was estimated using two different sets of replicate measures performed by the central analytical laboratory. Estimated standard deviations were similar to those previously reported. (Author 's abstract)
NASA Astrophysics Data System (ADS)
Randau, C.; Brokmeier, H. G.; Gan, W. M.; Hofmann, M.; Voeller, M.; Tekouo, W.; Al-hamdany, N.; Seidl, G.; Schreyer, A.
2015-09-01
The materials science neutron diffractometer STRESS-SPEC located at FRM II is a dedicated instrument for strain and pole figure measurements. Both methods make complementary demands on sample handling. On one hand pole figure measurements need a high degree of freedom to orient small samples and on the other hand in strain investigations it is often necessary to handle large and heavy components. Therefore a robot based sample positioning system was developed, which has the capability to provide both possibilities. Based on this new robot system further developments like a full automated sample changer system for texture measurements were accomplished. Moreover this system opens the door for combined strain and texture analysis at STRESS-SPEC.
Translational research in pediatrics III: bronchoalveolar lavage.
Radhakrishnan, Dhenuka; Yamashita, Cory; Gillio-Meina, Carolina; Fraser, Douglas D
2014-07-01
The role of flexible bronchoscopy and bronchoalveolar lavage (BAL) for the care of children with airway and pulmonary diseases is well established, with collected BAL fluid most often used clinically for microbiologic pathogen identification and cellular analyses. More recently, powerful analytic research methods have been used to investigate BAL samples to better understand the pathophysiological basis of pediatric respiratory disease. Investigations have focused on the cellular components contained in BAL fluid, such as macrophages, lymphocytes, neutrophils, eosinophils, and mast cells, as well as the noncellular components such as serum molecules, inflammatory proteins, and surfactant. Molecular techniques are frequently used to investigate BAL fluid for the presence of infectious pathologies and for cellular gene expression. Recent advances in proteomics allow identification of multiple protein expression patterns linked to specific respiratory diseases, whereas newer analytic techniques allow for investigations on surfactant quantification and function. These translational research studies on BAL fluid have aided our understanding of pulmonary inflammation and the injury/repair responses in children. We review the ethics and practices for the execution of BAL in children for translational research purposes, with an emphasis on the optimal handling and processing of BAL samples. Copyright © 2014 by the American Academy of Pediatrics.
Aseptic Handling of the MOMA Mass Spectrometer After Dry Heat Microbial Reduction
NASA Technical Reports Server (NTRS)
Lalime, Erin
2017-01-01
Mars Organic Molecule Analyzer Mass Spectrometer (MOMA-MS) is an instrument in the larger MOMA instrument suite for the European Space Agency (ESA) ExoMars 2020 Rover. As a life-detection instrument on a Mars landing mission, MOMA-MS has very stringent Planetary Protection (PP) bioburden requirements. Within the MOMA instrument suite, the hardware surfaces of the sample path must be cleaned to a level of 0.03 spore/sq m. To meet this requirement, a process called Dry Heat Microbial Reduction (DHMR) is used to decrease the number of viable spores by 4 orders of magnitude. Before DHMR, the hardware is handled using standard cleanroom practices, while after DHMR, all sample path surfaces must be handled aseptically when exposed. Aseptic handling of the sample path involves a number of strategies and protocols including working only in an aseptic ISO class 5 work space, limiting the amount of time of exposure, using sterile garmenting with sterile gloves, and using sterile tools. Before work begins, the aseptic workspace will be tested for bioburden and particle fallout, and all tools that will contact sample path surfaces must be sterilized. During the exposure activity, sterile garments will be worn, sterile tools will be handled in a 2 person set up so that the operator touches only the sterile tool and not the exterior surfaces of the sterile pouch, and the environment will be monitored with active and passive fallout for bioburden and particle levels. Any breach in the planetary protection cleanliness can necessitate repeating DHMR, which not only has significant cost and schedule implications, it also become a risk to hardware that is not rated for repeated long exposures to high temperatures.
PIMS sequencing extension: a laboratory information management system for DNA sequencing facilities.
Troshin, Peter V; Postis, Vincent Lg; Ashworth, Denise; Baldwin, Stephen A; McPherson, Michael J; Barton, Geoffrey J
2011-03-07
Facilities that provide a service for DNA sequencing typically support large numbers of users and experiment types. The cost of services is often reduced by the use of liquid handling robots but the efficiency of such facilities is hampered because the software for such robots does not usually integrate well with the systems that run the sequencing machines. Accordingly, there is a need for software systems capable of integrating different robotic systems and managing sample information for DNA sequencing services. In this paper, we describe an extension to the Protein Information Management System (PIMS) that is designed for DNA sequencing facilities. The new version of PIMS has a user-friendly web interface and integrates all aspects of the sequencing process, including sample submission, handling and tracking, together with capture and management of the data. The PIMS sequencing extension has been in production since July 2009 at the University of Leeds DNA Sequencing Facility. It has completely replaced manual data handling and simplified the tasks of data management and user communication. Samples from 45 groups have been processed with an average throughput of 10000 samples per month. The current version of the PIMS sequencing extension works with Applied Biosystems 3130XL 96-well plate sequencer and MWG 4204 or Aviso Theonyx liquid handling robots, but is readily adaptable for use with other combinations of robots. PIMS has been extended to provide a user-friendly and integrated data management solution for DNA sequencing facilities that is accessed through a normal web browser and allows simultaneous access by multiple users as well as facility managers. The system integrates sequencing and liquid handling robots, manages the data flow, and provides remote access to the sequencing results. The software is freely available, for academic users, from http://www.pims-lims.org/.
Ergovaline Stability in Tall Fescue Based on Sample Handling and Storage Methods
NASA Astrophysics Data System (ADS)
Lea, Krista; Smith, Lori; Gaskill, Cynthia; Coleman, Robert; Smith, S.
2014-09-01
Ergovaline is an ergot alkaloid produced by the endophyte Neotyphodium coenophialum (Morgan-Jones and Gams) found in tall fescue (Schedonorus arundinacea (Schreb.) Dumort.) and blamed for a multitude of livestock disorders. Ergovaline is known to be unstable and affected by many variables. The objective of this study was to determine the effect of sample handling and storage on the stability of ergovaline in tall fescue samples. Fresh tall fescue was collected from a horse farm in central Kentucky at three harvest dates and transported on ice to the University of Kentucky Veterinary Diagnostic Laboratory. Plant material was frozen in liquid nitrogen, milled and mixed before being allocated into different sub-samples. Three sub-samples were assigned to each of 14 sample handling or storage treatments. Sample handling included increased heat and UV light to simulate transportation in a vehicle and on ice in a cooler per standard transportation recommendations. Storage conditions included storage at 22oC, 5oC and -20oC for up to 28 days. Each sub-sample was then analyzed for ergovaline concentration using HPLC with fluorescence detection and this experiment was repeated for each harvest date. Sub-samples exposed to UV light and heat lost a significant fraction of ergovaline in 2 hours, while sub-samples stored on ice in a cooler showed no change in ergovaline in 2 hours. All sub-samples stored at 22oC, 5oC and -20oC lost a significant fraction of ergovaline in the first 24 hours of storage. There was little change in ergovaline in the freezer (-20oC) after the first 24 hours up to 28 days of storage but intermittent losses were observed at 22oC and 5oC. To obtain results that most closely represent levels in the field, all samples should be transported on ice to the laboratory immediately after harvest for same day analysis. If immediate testing is not possible, samples should be stored at -20oC until analysis.
Wölfel, Roman; Pfeffer, Martin; Essbauer, Sandra; Nerkelun, Sylke; Dobler, Gerhard
2006-11-01
Human adenoviruses (HAdV) may cause pharyngoconjunctival fever, follicular conjunctivitis or epidemic keratoconjunctivitis (EKC). Especially, outbreaks of the latter may lead to severe economic losses when preventive measures are implemented too late. Thus, a safe sampling method, proper specimen transport conditions and a fast and sensitive diagnostic technique is mandatory. Two commercially available virus transport systems (VTS) were compared with two NaCl-moisturised sampling devices, one of which comprises Dacron-tipped plastic-shafted swabs and the other a cotton-tipped wood-shafted swab, available in most ophthalmologists' offices. Downstream methods for specific detection of HAdV included direct immunofluorescence assay (IFA) of conjunctival swabs, virus isolation by cell culture and quantitative real-time polymerase chain reaction (qPCR). Furthermore, the influence of application of local anaesthetics prior to swabbing on subsequent detection of HAdV was investigated. Application of local anaesthetics had a positive influence on the amount of swabbed cells, thus increasing the chance of obtaining positive results by IFA. Neither isolation of HAdV by cell culture nor by qPCR was negatively influenced by this pretreatment. Surprisingly, both commercially available VTS performed significantly worse than the NaCl-moisturised swabs. This was shown with regard to virus recovery rates in cell culture as well as viral genome copy numbers in the qPCR. Based on our results, the following recommendations are provided to improve sampling, transport and diagnostic techniques regarding conjunctival swabs for diagnosis of human adenovirus infection: (1) application of local anaesthetics, (2) NaCl-moisturised VTS for shipment of specimens, and (3) detection of HAdV by qPCR. The latter method proved to be superior to virus isolation by cell culture, including subsequent identification by IFA, because it is faster, more sensitive and allows simultaneous handling of a number of samples. Hence, countermeasures to prevent further virus spread in an outbreak situation can be implemented earlier, thus reducing the number of subsequent adenoviral infections.
Simulating Scenes In Outer Space
NASA Technical Reports Server (NTRS)
Callahan, John D.
1989-01-01
Multimission Interactive Picture Planner, MIP, computer program for scientifically accurate and fast, three-dimensional animation of scenes in deep space. Versatile, reasonably comprehensive, and portable, and runs on microcomputers. New techniques developed to perform rapidly calculations and transformations necessary to animate scenes in scientifically accurate three-dimensional space. Written in FORTRAN 77 code. Primarily designed to handle Voyager, Galileo, and Space Telescope. Adapted to handle other missions.
How to Handle a Satellite Change in an Operational TWSTFT Network?
2010-11-01
42 nd Annual Precise Time and Time Interval (PTTI) Meeting 285 HOW TO HANDLE A SATELLITE CHANGE IN AN OPERATIONAL TWSTFT NETWORK...way satellite time and frequency transfer ( TWSTFT ) is a powerful technique because of its real-time capabilities. In principle, the time difference...between remote clocks is almost instantaneously known after a measurement session. Long-term TWSTFT operations have required changes between
Development of a high efficiency thin silicon solar cell
NASA Technical Reports Server (NTRS)
Lindmayer, J.; Wrigley, C. Y.
1977-01-01
A key to the success of this program was the breakthrough development of a technology for producing ultra-thin silicon slices which are very flexible, resilient, and tolerant of moderate handling abuse. Experimental topics investigated were thinning technology, gaseous junction diffusion, aluminum back alloying, internal reflectance, tantalum oxide anti-reflective coating optimization, slice flexibility, handling techniques, production rate limiting steps, low temperature behavior, and radiation tolerance.
A procedure to achieve fine control in MW processing of foods
NASA Astrophysics Data System (ADS)
Cuccurullo, G.; Cinquanta, L.; Sorrentino, G.
2007-01-01
A two-dimensional analytical model for predicting the unsteady temperature field in a cylindrical shaped body affected by spatially varying heat generation is presented. The dimensionless problem is solved analytically by using both partial solutions and the variation of parameters techniques. Having in mind industrial microwave heating for food pasteurization, the easy-to-handle solution is used to confirm the intrinsic lack of spatial uniformity of such a treatment in comparison to the traditional one. From an experimental point of view, a batch pasteurization treatment was realized to compare the effect of two different control techniques both based on IR thermography readout: the former assured a classical PID control, while the latter was based on a "shadowing" technique, consisting in covering portions of the sample which are hot enough with a mobile metallic screen. A measure of the effectiveness of the two control techniques was obtained by evaluating the thermal death curves of a strain Lactobacillus plantarum submitted to pasteurization temperatures. Preliminary results showed meaningful increases in the microwave thermal inactivation of the L. plantarum and similar significant decreases in thermal inactivation time with respect to the traditional pasteurization thermal treatment.
NASA Astrophysics Data System (ADS)
Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.
2016-05-01
Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.
Final Report: Sampling-Based Algorithms for Estimating Structure in Big Data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matulef, Kevin Michael
The purpose of this project was to develop sampling-based algorithms to discover hidden struc- ture in massive data sets. Inferring structure in large data sets is an increasingly common task in many critical national security applications. These data sets come from myriad sources, such as network traffic, sensor data, and data generated by large-scale simulations. They are often so large that traditional data mining techniques are time consuming or even infeasible. To address this problem, we focus on a class of algorithms that do not compute an exact answer, but instead use sampling to compute an approximate answer using fewermore » resources. The particular class of algorithms that we focus on are streaming algorithms , so called because they are designed to handle high-throughput streams of data. Streaming algorithms have only a small amount of working storage - much less than the size of the full data stream - so they must necessarily use sampling to approximate the correct answer. We present two results: * A streaming algorithm called HyperHeadTail , that estimates the degree distribution of a graph (i.e., the distribution of the number of connections for each node in a network). The degree distribution is a fundamental graph property, but prior work on estimating the degree distribution in a streaming setting was impractical for many real-world application. We improve upon prior work by developing an algorithm that can handle streams with repeated edges, and graph structures that evolve over time. * An algorithm for the task of maintaining a weighted subsample of items in a stream, when the items must be sampled according to their weight, and the weights are dynamically changing. To our knowledge, this is the first such algorithm designed for dynamically evolving weights. We expect it may be useful as a building block for other streaming algorithms on dynamic data sets.« less
Tin, Mandy Man-Ying; Economo, Evan Philip; Mikheyev, Alexander Sergeyevich
2014-01-01
Ancient and archival DNA samples are valuable resources for the study of diverse historical processes. In particular, museum specimens provide access to biotas distant in time and space, and can provide insights into ecological and evolutionary changes over time. However, archival specimens are difficult to handle; they are often fragile and irreplaceable, and typically contain only short segments of denatured DNA. Here we present a set of tools for processing such samples for state-of-the-art genetic analysis. First, we report a protocol for minimally destructive DNA extraction of insect museum specimens, which produced sequenceable DNA from all of the samples assayed. The 11 specimens analyzed had fragmented DNA, rarely exceeding 100 bp in length, and could not be amplified by conventional PCR targeting the mitochondrial cytochrome oxidase I gene. Our approach made these samples amenable to analysis with commonly used next-generation sequencing-based molecular analytic tools, including RAD-tagging and shotgun genome re-sequencing. First, we used museum ant specimens from three species, each with its own reference genome, for RAD-tag mapping. Were able to use the degraded DNA sequences, which were sequenced in full, to identify duplicate reads and filter them prior to base calling. Second, we re-sequenced six Hawaiian Drosophila species, with millions of years of divergence, but with only a single available reference genome. Despite a shallow coverage of 0.37 ± 0.42 per base, we could recover a sufficient number of overlapping SNPs to fully resolve the species tree, which was consistent with earlier karyotypic studies, and previous molecular studies, at least in the regions of the tree that these studies could resolve. Although developed for use with degraded DNA, all of these techniques are readily applicable to more recent tissue, and are suitable for liquid handling automation.
Argubi-Wollesen, Andreas; Wollesen, Bettina; Leitner, Martin; Mattes, Klaus
2017-03-01
The purpose of this review is to name and describe the important factors of musculoskeletal strain originating from pushing and pulling tasks such as cart handling that are commonly found in industrial contexts. A literature database search was performed using the research platform Web of Science. For a study to be included in this review differences in measured or calculated strain had to be investigated with regard to: (1) cart weight/ load; (2) handle position and design; (3) exerted forces; (4) handling task (push and pull); or (5) task experience. Thirteen studies met the inclusion criteria and proved to be of adequate methodological quality by the standards of the Alberta Heritage Foundation for Medical Research. External load or cart weight proved to be the most influential factor of strain. The ideal handle positions ranged from hip to shoulder height and were dependent on the strain factor that was focused on as well as the handling task. Furthermore, task experience and subsequently handling technique were also key to reducing strain. Workplace settings that regularly involve pushing and pulling should be checked for potential improvements with regards to lower weight of the loaded handling device, handle design, and good practice guidelines to further reduce musculoskeletal disease prevalence.
Factors influencing moisture analysis in the 3013 destructive examination surveillance program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scogin, J. H.
Thermogravimetric analysis of a solid sample with mass spectrometry (TGA-MS) of the evolved gas is used in the destructive examination (DE) portion of the Integrated Surveillance Program to quantify the moisture content of the material stored in a 3013 container. As with any measurement determined from a small sample, the collection, storage, transportation, and handling of the sample can affect its ability to represent the properties of the bulk material. During the course of the DE program, questions have periodically arisen concerning the ability of the moisture sample to reflect reliably the actual moisture content of the entire material storedmore » in the 3013 container. Most concerns are related to the ability to collect a representative sample and to preserve the moisture content of the sample between collection and analysis. Recent delays in analysis caused by maintenance issues with the TGA-MS instrument presented a unique opportunity to document and quantify the effects various factors have on the TGA-MS moisture measurement. This report will use recent data to document the effects that current sample collection and handling practices have on the TGA-MS moisture measurement. Some suggestions will be made which could improve the current sample collection and handling practices for the TGA-MS moisture measurement so that the analytical results more accurately reflect the moisture content of the material stored in the 3013 container.« less
Easy and safe coated optical fiber direct connection without handling bare optical fiber
NASA Astrophysics Data System (ADS)
Saito, Kotaro; Kihara, Mitsuru; Shimizu, Tomoya; Kurashima, Toshio
2015-06-01
We propose a novel field installable splicing technique for the direct connection of 250 μm diameter coated optical fiber that does not require bare optical fiber to be handled. Our proposed technique can realize a low insertion loss over a wide field installation temperature range of -10-40 °C. The keys to coated optical fiber direct connection are a cleaving technique and a technique for removing coated optical fiber. As the cleaving technique, we employed a method where the fiber is stretched and then a blade is pushed perpendicularly against the stretched fiber. As a result we confirmed that fiber endfaces cleaved at -10-40 °C were all mirror endfaces. With the removal technique, the coating is removed inside the connecting component by incorporating a circular cone shaped coating removal part. A mechanical splice based on these techniques successfully achieved a low insertion loss of less than 0.11 dB and a return loss of more than 50 dB at -10, 20, and 40 °C. In addition, the temperature cycle characteristics were stable over a wide temperature range of -40-75 °C.
CANISTER TRANSFER SYSTEM DESCRIPTION DOCUMENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
B. Gorpani
2000-06-23
The Canister Transfer System receives transportation casks containing large and small disposable canisters, unloads the canisters from the casks, stores the canisters as required, loads them into disposal containers (DCs), and prepares the empty casks for re-shipment. Cask unloading begins with cask inspection, sampling, and lid bolt removal operations. The cask lids are removed and the canisters are unloaded. Small canisters are loaded directly into a DC, or are stored until enough canisters are available to fill a DC. Large canisters are loaded directly into a DC. Transportation casks and related components are decontaminated as required, and empty casks aremore » prepared for re-shipment. One independent, remotely operated canister transfer line is provided in the Waste Handling Building System. The canister transfer line consists of a Cask Transport System, Cask Preparation System, Canister Handling System, Disposal Container Transport System, an off-normal canister handling cell with a transfer tunnel connecting the two cells, and Control and Tracking System. The Canister Transfer System operating sequence begins with moving transportation casks to the cask preparation area with the Cask Transport System. The Cask Preparation System prepares the cask for unloading and consists of cask preparation manipulator, cask inspection and sampling equipment, and decontamination equipment. The Canister Handling System unloads the canister(s) and places them into a DC. Handling equipment consists of a bridge crane hoist, DC loading manipulator, lifting fixtures, and small canister staging racks. Once the cask has been unloaded, the Cask Preparation System decontaminates the cask exterior and returns it to the Carrier/Cask Handling System via the Cask Transport System. After the DC is fully loaded, the Disposal Container Transport System moves the DC to the Disposal Container Handling System for welding. To handle off-normal canisters, a separate off-normal canister handling cell is located adjacent to the canister transfer cell and is interconnected to the transfer cell by means of the off-normal canister transfer tunnel. All canister transfer operations are controlled by the Control and Tracking System. The system interfaces with the Carrier/Cask Handling System for incoming and outgoing transportation casks. The system also interfaces with the Disposal Container Handling System, which prepares the DC for loading and subsequently seals the loaded DC. The system support interfaces are the Waste Handling Building System and other internal Waste Handling Building (WHB) support systems.« less
Employee and customer handling of nicotine-containing e-liquids in vape shops.
Garcia, Robert; Allem, Jon Patrick; Baezconde-Garbanati, Lourdes; Unger, Jennifer Beth; Sussman, Steve
2016-01-01
Vape shops sell electronic cigarettes and related products such as e-liquids, which may contain nicotine. Direct contact with nicotine can lead to adverse health effects, and few regulations exist on how nicotine is handled in vape shops. This study examined how customers and employees come into contact with, and handle, nicotine-containing e-liquids in vape shops with the goal of informing potential future regulation of nicotine handling in vape shops. Data were collected from 77 vape shops in the Los Angeles basin. Characteristics of the shops were documented by employee interviews and in store observations. Data collection was focused on shops located in areas with high concentrations of communities of interest; 20 shops from African-American communities, 17 from Hispanic communities, 18 from Korean communities, and 22 from non-Hispanic White communities. Half of the vape shops allowed customers to sample e-liquids with nicotine. Most of the shops (83%) provided self-service sampling stations for customers. A majority of shop employees (72%) reported that spills of e-liquids containing nicotine had occurred in the past. While 64% of the shops provided safety equipment, only 34% provided equipment for proper nicotine handling. Furthermore, 62% of shop employees reported handling nicotine without gloves or other safety equipment. Regulation on the handling of nicotine by customers and vape shop employees is important to prevent unsafe practices and subsequent injury. The frequent occurrence of spills and limited availability of safety equipment in vape shops highlights the need for the creation and enforcement of regulations to protect employees and customers. Appropriate safety training and equipment should be provided to employees to prevent accidental exposure to nicotine. Information on ways to safely handle nicotine should be communicated to vape shop employees and customers.
Employee and customer handling of nicotine-containing e-liquids in vape shops
Garcia, Robert; Allem, Jon Patrick; Baezconde-Garbanati, Lourdes; Unger, Jennifer Beth; Sussman, Steve
2017-01-01
INTRODUCTION Vape shops sell electronic cigarettes and related products such as e-liquids, which may contain nicotine. Direct contact with nicotine can lead to adverse health effects, and few regulations exist on how nicotine is handled in vape shops. This study examined how customers and employees come into contact with, and handle, nicotine-containing e-liquids in vape shops with the goal of informing potential future regulation of nicotine handling in vape shops. METHODS Data were collected from 77 vape shops in the Los Angeles basin. Characteristics of the shops were documented by employee interviews and in store observations. Data collection was focused on shops located in areas with high concentrations of communities of interest; 20 shops from African-American communities, 17 from Hispanic communities, 18 from Korean communities, and 22 from non-Hispanic White communities. RESULTS Half of the vape shops allowed customers to sample e-liquids with nicotine. Most of the shops (83%) provided self-service sampling stations for customers. A majority of shop employees (72%) reported that spills of e-liquids containing nicotine had occurred in the past. While 64% of the shops provided safety equipment, only 34% provided equipment for proper nicotine handling. Furthermore, 62% of shop employees reported handling nicotine without gloves or other safety equipment. CONCLUSIONS Regulation on the handling of nicotine by customers and vape shop employees is important to prevent unsafe practices and subsequent injury. The frequent occurrence of spills and limited availability of safety equipment in vape shops highlights the need for the creation and enforcement of regulations to protect employees and customers. Appropriate safety training and equipment should be provided to employees to prevent accidental exposure to nicotine. Information on ways to safely handle nicotine should be communicated to vape shop employees and customers. PMID:28660255
Flexible Electrostatic Technologies for Capture and Handling, Phase 1
NASA Technical Reports Server (NTRS)
Bryan, Thomas
2015-01-01
Fundamental to many of NASA's in-space transportation missions is the capture and handling of various objects and vehicles in various orbits for servicing, debris disposal, sample retrieval, and assembly without the benefit of sufficient grapple fixtures and docking ports. To perform similar material handling tasks on Earth, pincher grippers, suction grippers, or magnetic chucks are used, but are unable to reliably grip aluminum and composite spacecraft, insulation, radiators, solar arrays, or extra-terrestrial objects in the vacuum of outer space without dedicated handles in the right places. The electronic Flexible Electrostatic Technologies for space Capture and Handling (FETCH) will enable reliable and compliant gripping (soft dock) of practically any object in various orbits or surfaces without dedicated mechanical features, very low impact capture, and built-in proximity sensing without any conventional actuators. Originally developed to handle semiconductor and glass wafers during vacuum chamber processing without contamination, the normal rigid wafer handling chucks are replaced with thin metal foil segments laminated in flexible insulation driven by commercial off-the-shelf solid state, high-voltage power supplies. Preliminary testing in NASA Marshall Space Flight Center's (MSFC's) Flat Floor Robotics Lab demonstrated compliant alignment and gripping with a full-sized, 150-lb microsat mockup and translation before a clean release with a flip of a switch. The flexible electrostatic gripper pads can be adapted to various space applications with different sizes, shapes, and foil electrode layouts even with openings through the gripper pads for addition of guidance sensors or injection of permanent adhesives. With gripping forces estimated between 0.5 and 2.5 lb/in2 or 70-300 lb/ft2 of surface contact, the FETCH can turn on and off rapidly and repeatedly to enable sample handling, soft docking, in-space assembly, precision relocation, and surface translation for accurate anchoring.
NASA Astrophysics Data System (ADS)
Momoh, James A.; Salkuti, Surender Reddy
2016-06-01
This paper proposes a stochastic optimization technique for solving the Voltage/VAr control problem including the load demand and Renewable Energy Resources (RERs) variation. The RERs often take along some inputs like stochastic behavior. One of the important challenges i. e., Voltage/VAr control is a prime source for handling power system complexity and reliability, hence it is the fundamental requirement for all the utility companies. There is a need for the robust and efficient Voltage/VAr optimization technique to meet the peak demand and reduction of system losses. The voltages beyond the limit may damage costly sub-station devices and equipments at consumer end as well. Especially, the RERs introduces more disturbances and some of the RERs are not even capable enough to meet the VAr demand. Therefore, there is a strong need for the Voltage/VAr control in RERs environment. This paper aims at the development of optimal scheme for Voltage/VAr control involving RERs. In this paper, Latin Hypercube Sampling (LHS) method is used to cover full range of variables by maximally satisfying the marginal distribution. Here, backward scenario reduction technique is used to reduce the number of scenarios effectively and maximally retain the fitting accuracy of samples. The developed optimization scheme is tested on IEEE 24 bus Reliability Test System (RTS) considering the load demand and RERs variation.
Nanoplatforms for Detection, Remediation and Protection Against Chem-Bio Warfare
NASA Astrophysics Data System (ADS)
Denkbaş, E. B.; Bayram, C.; Kavaz, D.; Çirak, T.; Demirbilek, M.
Chemical and biological substances have been used as warfare agents by terrorists by varying degree of sophistication. It is critical that these agents be detected in real-time with high level of sensitively, specificity, and accuracy. Many different types of techniques and systems have been developed to detect these agents. But there are some limitations in these conventional techniques and systems. Limitations include the collection, handling and sampling procedures, detection limits, sample transfer, expensive equipment, personnel training, and detection materials. Due to the unique properties such as quantum effect, very high surface/volume ratio, enhanced surface reactivity, conductivity, electrical and magnetic properties of the nanomaterials offer great opportunity to develop very fast, sensitive, accurate and cost effective detection techniques and systems to detect chemical and biological (chem.-bio) warfare agents. Furthermore, surface modification of the materials is very easy and effective way to get functional or smart surfaces to be used as nano-biosensor platform. In that respect many different types of nanomaterials have been developed and used for the detection, remediation and protection, such as gold and silver nanoparticles, quantum dots, Nano chips and arrays, fluorescent polymeric and magnetic nanoparticles, fiber optic and cantilever based nanobiosensors, nanofibrillar nanostructures etc. This study summarizes preparation and characterization of nanotechnology based approaches for the detection of and remediation and protection against chem.-bio warfare agents.
Law enforcement tools available at the Savannah River Site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hofstetter, K.J.
A number of nuclear technologies developed and applied at the Savannah River Site in support of nuclear weapons material production and environmental remediation can be applied to problems in law enforcement. Techniques and equipment for high-sensitivity analyses of samples are available to identify and quantify trace elements and establish origins and histories of forensic evidence removed from crime scenes. While some of theses capabilities are available at local crime laboratories, state-of-the-art equipment and breakthroughs in analytical techniques are continually being developed at DOE laboratories. Extensive experience with the handling of radioactive samples at the DOE labs minimizes the chances ofmore » cross-contamination of evidence received from law enforcement. In addition to high-sensitivity analyses, many of the field techniques developed for use in a nuclear facility can assist law enforcement personnel in detecting illicit materials and operations, in retrieving of pertinent evidence and in surveying crime scenes. Some of these tools include chemical sniffers, hand-held detectors, thermal imaging, etc. In addition, mobile laboratories can be deployed to a crime scene to provide field screening of potential evidence. A variety of portable sensors can be deployed on vehicle, aerial, surface or submersible platforms to assist in the location of pertinent evidence or illicit operations. Several specific nuclear technologies available to law enforcement and their potential uses are discussed.« less
Assessment of Sentinel Node Biopsies With Full-Field Optical Coherence Tomography.
Grieve, Kate; Mouslim, Karima; Assayag, Osnath; Dalimier, Eugénie; Harms, Fabrice; Bruhat, Alexis; Boccara, Claude; Antoine, Martine
2016-04-01
Current techniques for the intraoperative analysis of sentinel lymph nodes during breast cancer surgery present drawbacks such as time and tissue consumption. Full-field optical coherence tomography is a novel noninvasive, high-resolution, fast imaging technique. This study investigated the use of full-field optical coherence tomography as an alternative technique for the intraoperative analysis of sentinel lymph nodes. Seventy-one axillary lymph nodes from 38 patients at Tenon Hospital were imaged minutes after excision with full-field optical coherence tomography in the pathology laboratory, before being handled for histological analysis. A pathologist performed a blind diagnosis (benign/malignant), based on the full-field optical coherence tomography images alone, which resulted in a sensitivity of 92% and a specificity of 83% (n = 65 samples). Regular feedback was given during the blind diagnosis, with thorough analysis of the images, such that features of normal and suspect nodes were identified in the images and compared with histology. A nonmedically trained imaging expert also performed a blind diagnosis aided by the reading criteria defined by the pathologist, which resulted in 85% sensitivity and 90% specificity (n = 71 samples). The number of false positives of the pathologist was reduced by 3 in a second blind reading a few months later. These results indicate that following adequate training, full-field optical coherence tomography can be an effective noninvasive diagnostic tool for extemporaneous sentinel node biopsy qualification. © The Author(s) 2015.
45 CFR 74.91 - Alternative dispute resolution.
Code of Federal Regulations, 2010 CFR
2010-10-01
... resolution (ADR) techniques. ADR often is effective in reducing the cost, delay and contentiousness involved in appeals and other traditional ways of handling disputes. ADR techniques include mediation, neutral evaluation and other consensual methods. Information about ADR is available from the HHS Dispute Resolution...
45 CFR 74.91 - Alternative dispute resolution.
Code of Federal Regulations, 2011 CFR
2011-10-01
... resolution (ADR) techniques. ADR often is effective in reducing the cost, delay and contentiousness involved in appeals and other traditional ways of handling disputes. ADR techniques include mediation, neutral evaluation and other consensual methods. Information about ADR is available from the HHS Dispute Resolution...
Flight testing and frequency domain analysis for rotorcraft handling qualities characteristics
NASA Technical Reports Server (NTRS)
Ham, Johnnie A.; Gardner, Charles K.; Tischler, Mark B.
1993-01-01
A demonstration of frequency domain flight testing techniques and analyses was performed on a U.S. Army OH-58D helicopter in support of the OH-58D Airworthiness and Flight Characteristics Evaluation and the Army's development and ongoing review of Aeronautical Design Standard 33C, Handling Qualities Requirements for Military Rotorcraft. Hover and forward flight (60 knots) tests were conducted in 1 flight hour by Army experimental test pilots. Further processing of the hover data generated a complete database of velocity, angular rate, and acceleration frequency responses to control inputs. A joint effort was then undertaken by the Airworthiness Qualification Test Directorate (AQTD) and the U.S. Army Aeroflightdynamics Directorate (AFDD) to derive handling qualities information from the frequency response database. A significant amount of information could be extracted from the frequency domain database using a variety of approaches. This report documents numerous results that have been obtained from the simple frequency domain tests; in many areas, these results provide more insight into the aircraft dynamics that affect handling qualities than to traditional flight tests. The handling qualities results include ADS-33C bandwidth and phase delay calculations, vibration spectral determinations, transfer function models to examine single axis results, and a six degree of freedom fully coupled state space model. The ability of this model to accurately predict aircraft responses was verified using data from pulse inputs. This report also documents the frequency-sweep flight test technique and data analysis used to support the tests.
Correcting for Microbial Blooms in Fecal Samples during Room-Temperature Shipping.
Amir, Amnon; McDonald, Daniel; Navas-Molina, Jose A; Debelius, Justine; Morton, James T; Hyde, Embriette; Robbins-Pianka, Adam; Knight, Rob
2017-01-01
The use of sterile swabs is a convenient and common way to collect microbiome samples, and many studies have shown that the effects of room-temperature storage are smaller than physiologically relevant differences between subjects. However, several bacterial taxa, notably members of the class Gammaproteobacteria , grow at room temperature, sometimes confusing microbiome results, particularly when stability is assumed. Although comparative benchmarking has shown that several preservation methods, including the use of 95% ethanol, fecal occult blood test (FOBT) and FTA cards, and Omnigene-GUT kits, reduce changes in taxon abundance during room-temperature storage, these techniques all have drawbacks and cannot be applied retrospectively to samples that have already been collected. Here we performed a meta-analysis using several different microbiome sample storage condition studies, showing consistent trends in which specific bacteria grew (i.e., "bloomed") at room temperature, and introduce a procedure for removing the sequences that most distort analyses. In contrast to similarity-based clustering using operational taxonomic units (OTUs), we use a new technique called "Deblur" to identify the exact sequences corresponding to blooming taxa, greatly reducing false positives and also dramatically decreasing runtime. We show that applying this technique to samples collected for the American Gut Project (AGP), for which participants simply mail samples back without the use of ice packs or other preservatives, yields results consistent with published microbiome studies performed with frozen or otherwise preserved samples. IMPORTANCE In many microbiome studies, the necessity to store samples at room temperature (i.e., remote fieldwork) and the ability to ship samples without hazardous materials that require special handling training, such as ethanol (i.e., citizen science efforts), is paramount. However, although room-temperature storage for a few days has been shown not to obscure physiologically relevant microbiome differences between comparison groups, there are still changes in specific bacterial taxa, notably, in members of the class Gammaproteobacteria , that can make microbiome profiles difficult to interpret. Here we identify the most problematic taxa and show that removing sequences from just a few fast-growing taxa is sufficient to correct microbiome profiles.
Correcting for Microbial Blooms in Fecal Samples during Room-Temperature Shipping
Amir, Amnon; McDonald, Daniel; Navas-Molina, Jose A.; Debelius, Justine; Morton, James T.; Hyde, Embriette; Robbins-Pianka, Adam
2017-01-01
ABSTRACT The use of sterile swabs is a convenient and common way to collect microbiome samples, and many studies have shown that the effects of room-temperature storage are smaller than physiologically relevant differences between subjects. However, several bacterial taxa, notably members of the class Gammaproteobacteria, grow at room temperature, sometimes confusing microbiome results, particularly when stability is assumed. Although comparative benchmarking has shown that several preservation methods, including the use of 95% ethanol, fecal occult blood test (FOBT) and FTA cards, and Omnigene-GUT kits, reduce changes in taxon abundance during room-temperature storage, these techniques all have drawbacks and cannot be applied retrospectively to samples that have already been collected. Here we performed a meta-analysis using several different microbiome sample storage condition studies, showing consistent trends in which specific bacteria grew (i.e., “bloomed”) at room temperature, and introduce a procedure for removing the sequences that most distort analyses. In contrast to similarity-based clustering using operational taxonomic units (OTUs), we use a new technique called “Deblur” to identify the exact sequences corresponding to blooming taxa, greatly reducing false positives and also dramatically decreasing runtime. We show that applying this technique to samples collected for the American Gut Project (AGP), for which participants simply mail samples back without the use of ice packs or other preservatives, yields results consistent with published microbiome studies performed with frozen or otherwise preserved samples. IMPORTANCE In many microbiome studies, the necessity to store samples at room temperature (i.e., remote fieldwork) and the ability to ship samples without hazardous materials that require special handling training, such as ethanol (i.e., citizen science efforts), is paramount. However, although room-temperature storage for a few days has been shown not to obscure physiologically relevant microbiome differences between comparison groups, there are still changes in specific bacterial taxa, notably, in members of the class Gammaproteobacteria, that can make microbiome profiles difficult to interpret. Here we identify the most problematic taxa and show that removing sequences from just a few fast-growing taxa is sufficient to correct microbiome profiles. PMID:28289733
Xu, Yi-Hua; Manoharan, Herbert T; Pitot, Henry C
2007-09-01
The bisulfite genomic sequencing technique is one of the most widely used techniques to study sequence-specific DNA methylation because of its unambiguous ability to reveal DNA methylation status to the order of a single nucleotide. One characteristic feature of the bisulfite genomic sequencing technique is that a number of sample sequence files will be produced from a single DNA sample. The PCR products of bisulfite-treated DNA samples cannot be sequenced directly because they are heterogeneous in nature; therefore they should be cloned into suitable plasmids and then sequenced. This procedure generates an enormous number of sample DNA sequence files as well as adding extra bases belonging to the plasmids to the sequence, which will cause problems in the final sequence comparison. Finding the methylation status for each CpG in each sample sequence is not an easy job. As a result CpG PatternFinder was developed for this purpose. The main functions of the CpG PatternFinder are: (i) to analyze the reference sequence to obtain CpG and non-CpG-C residue position information. (ii) To tailor sample sequence files (delete insertions and mark deletions from the sample sequence files) based on a configuration of ClustalW multiple alignment. (iii) To align sample sequence files with a reference file to obtain bisulfite conversion efficiency and CpG methylation status. And, (iv) to produce graphics, highlighted aligned sequence text and a summary report which can be easily exported to Microsoft Office suite. CpG PatternFinder is designed to operate cooperatively with BioEdit, a freeware on the internet. It can handle up to 100 files of sample DNA sequences simultaneously, and the total CpG pattern analysis process can be finished in minutes. CpG PatternFinder is an ideal software tool for DNA methylation studies to determine the differential methylation pattern in a large number of individuals in a population. Previously we developed the CpG Analyzer program; CpG PatternFinder is our further effort to create software tools for DNA methylation studies.
Software techniques for a distributed real-time processing system. [for spacecraft
NASA Technical Reports Server (NTRS)
Lesh, F.; Lecoq, P.
1976-01-01
The paper describes software techniques developed for the Unified Data System (UDS), a distributed processor network for control and data handling onboard a planetary spacecraft. These techniques include a structured language for specifying the programs contained in each module, and a small executive program in each module which performs scheduling and implements the module task.
Advanced Curation: Solving Current and Future Sample Return Problems
NASA Technical Reports Server (NTRS)
Fries, M.; Calaway, M.; Evans, C.; McCubbin, F.
2015-01-01
Advanced Curation is a wide-ranging and comprehensive research and development effort at NASA Johnson Space Center that identifies and remediates sample related issues. For current collections, Advanced Curation investigates new cleaning, verification, and analytical techniques to assess their suitability for improving curation processes. Specific needs are also assessed for future sample return missions. For each need, a written plan is drawn up to achieve the requirement. The plan draws while upon current Curation practices, input from Curators, the analytical expertise of the Astromaterials Research and Exploration Science (ARES) team, and suitable standards maintained by ISO, IEST, NIST and other institutions. Additionally, new technologies are adopted on the bases of need and availability. Implementation plans are tested using customized trial programs with statistically robust courses of measurement, and are iterated if necessary until an implementable protocol is established. Upcoming and potential NASA missions such as OSIRIS-REx, the Asteroid Retrieval Mission (ARM), sample return missions in the New Frontiers program, and Mars sample return (MSR) all feature new difficulties and specialized sample handling requirements. The Mars 2020 mission in particular poses a suite of challenges since the mission will cache martian samples for possible return to Earth. In anticipation of future MSR, the following problems are among those under investigation: What is the most efficient means to achieve the less than 1.0 ng/sq cm total organic carbon (TOC) cleanliness required for all sample handling hardware? How do we maintain and verify cleanliness at this level? The Mars 2020 Organic Contamination Panel (OCP) predicts that organic carbon, if present, will be present at the "one to tens" of ppb level in martian near-surface samples. The same samples will likely contain wt% perchlorate salts, or approximately 1,000,000x as much perchlorate oxidizer as organic carbon. The chemical kinetics of this reaction are poorly understood at present under the conditions of cached or curated martian samples. Among other parameters, what is the maximum temperature allowed during storage in order to preserve native martian organic compounds for analysis? What is the best means to collect headspace gases from cached martian (and other) samples? This gas will contain not only martian atmosphere but also off-gassed volatiles from the cached solids.
Carr, R.S.; Chapman, D.C.
1995-01-01
A series of studies was conducted to compare different porewater extraction techniques and to evaluate the effects of sediment and porewater storage conditions on the toxicity of pore water, using assays with the sea urchin Arbacia punctulata. If care is taken in the selection of materials, several different porewater extraction techniques (pressurized squeezing, centrifugation, vacuum) yield samples with similar toxicity. Where the primary contaminants of concern are highly hydrophobic organic compounds, centrifugation is the method of choice for minimizing the loss of contaminants during the extraction procedure. No difference was found in the toxicity of pore water obtained with the Teflon® and polyvinyl chloride pressurized extraction devices. Different types of filters in the squeeze extraction devices apparently adsorbed soluble contaminants to varying degrees. The amount of fine suspended particulate material remaining in the pore water after the initial extraction varied among the methods. For most of the sediments tested, freezing and thawing did not affect the toxicity of porewater samples obtained by the pressurized squeeze extraction method. Pore water obtained by other methods (centrifugation, vacuum) and frozen without additional removal of suspended particulates by centrifugation may exhibit increased toxicity compared with the unfrozen sample.The toxicity of pore water extracted from refrigerated (4°C) sediments exhibited substantial short-term (days, weeks) changes. Similarly, sediment pore water extracted over time from a simulated amphipod solid-phase toxicity test changed substantially in toxicity. For the sediments tested, the direction and magnitude of change in toxicity of pore water extracted from both refrigerated and solid-phase test sediments was unpredictable.
An Optimal Strategy for Accurate Bulge-to-disk Decomposition of Disk Galaxies
NASA Astrophysics Data System (ADS)
Gao, Hua; Ho, Luis C.
2017-08-01
The development of two-dimensional (2D) bulge-to-disk decomposition techniques has shown their advantages over traditional one-dimensional (1D) techniques, especially for galaxies with non-axisymmetric features. However, the full potential of 2D techniques has yet to be fully exploited. Secondary morphological features in nearby disk galaxies, such as bars, lenses, rings, disk breaks, and spiral arms, are seldom accounted for in 2D image decompositions, even though some image-fitting codes, such as GALFIT, are capable of handling them. We present detailed, 2D multi-model and multi-component decomposition of high-quality R-band images of a representative sample of nearby disk galaxies selected from the Carnegie-Irvine Galaxy Survey, using the latest version of GALFIT. The sample consists of five barred and five unbarred galaxies, spanning Hubble types from S0 to Sc. Traditional 1D decomposition is also presented for comparison. In detailed case studies of the 10 galaxies, we successfully model the secondary morphological features. Through a comparison of best-fit parameters obtained from different input surface brightness models, we identify morphological features that significantly impact bulge measurements. We show that nuclear and inner lenses/rings and disk breaks must be properly taken into account to obtain accurate bulge parameters, whereas outer lenses/rings and spiral arms have a negligible effect. We provide an optimal strategy to measure bulge parameters of typical disk galaxies, as well as prescriptions to estimate realistic uncertainties of them, which will benefit subsequent decomposition of a larger galaxy sample.
An Optimal Strategy for Accurate Bulge-to-disk Decomposition of Disk Galaxies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao Hua; Ho, Luis C.
The development of two-dimensional (2D) bulge-to-disk decomposition techniques has shown their advantages over traditional one-dimensional (1D) techniques, especially for galaxies with non-axisymmetric features. However, the full potential of 2D techniques has yet to be fully exploited. Secondary morphological features in nearby disk galaxies, such as bars, lenses, rings, disk breaks, and spiral arms, are seldom accounted for in 2D image decompositions, even though some image-fitting codes, such as GALFIT, are capable of handling them. We present detailed, 2D multi-model and multi-component decomposition of high-quality R -band images of a representative sample of nearby disk galaxies selected from the Carnegie-Irvine Galaxymore » Survey, using the latest version of GALFIT. The sample consists of five barred and five unbarred galaxies, spanning Hubble types from S0 to Sc. Traditional 1D decomposition is also presented for comparison. In detailed case studies of the 10 galaxies, we successfully model the secondary morphological features. Through a comparison of best-fit parameters obtained from different input surface brightness models, we identify morphological features that significantly impact bulge measurements. We show that nuclear and inner lenses/rings and disk breaks must be properly taken into account to obtain accurate bulge parameters, whereas outer lenses/rings and spiral arms have a negligible effect. We provide an optimal strategy to measure bulge parameters of typical disk galaxies, as well as prescriptions to estimate realistic uncertainties of them, which will benefit subsequent decomposition of a larger galaxy sample.« less
A Sample Handling System for Mars Sample Return - Design and Status
NASA Astrophysics Data System (ADS)
Allouis, E.; Renouf, I.; Deridder, M.; Vrancken, D.; Gelmi, R.; Re, E.
2009-04-01
A mission to return atmosphere and soil samples form the Mars is highly desired by planetary scientists from around the world and space agencies are starting preparation for the launch of a sample return mission in the 2020 timeframe. Such a mission would return approximately 500 grams of atmosphere, rock and soil samples to Earth by 2025. Development of a wide range of new technology will be critical to the successful implementation of such a challenging mission. Technical developments required to realise the mission include guided atmospheric entry, soft landing, sample handling robotics, biological sealing, Mars atmospheric ascent sample rendezvous & capture and Earth return. The European Space Agency has been performing system definition studies along with numerous technology development studies under the framework of the Aurora programme. Within the scope of these activities Astrium has been responsible for defining an overall sample handling architecture in collaboration with European partners (sample acquisition and sample capture, Galileo Avionica; sample containment and automated bio-sealing, Verhaert). Our work has focused on the definition and development of the robotic systems required to move the sample through the transfer chain. This paper presents the Astrium team's high level design for the surface transfer system and the orbiter transfer system. The surface transfer system is envisaged to use two robotic arms of different sizes to allow flexible operations and to enable sample transfer over relatively large distances (~2 to 3 metres): The first to deploy/retract the Drill Assembly used for sample collection, the second for the transfer of the Sample Container (the vessel containing all the collected samples) from the Drill Assembly to the Mars Ascent Vehicle (MAV). The sample transfer actuator also features a complex end-effector for handling the Sample Container. The orbiter transfer system will transfer the Sample Container from the capture mechanism through a bio-sealing system to the Earth Return Capsule (ERC) and has distinctly different requirements from the surface transfer system. The operations required to transfer the samples to the ERC are clearly defined and make use of mechanisms specifically designed for the job rather than robotic arms. Though it is mechanical rather than robotic, the design of the orbiter transfer system is very complex in comparison to most previous missions to fulfil all the scientific and technological requirements. Further mechanisms will be required to lock the samples into the ERC and to close the door at the rear of the ERC through which the samples have been inserted. Having performed this overall definition study, Astrium is now leading the next step of the development of the MSR sample handling: the Mars Surface Sample Transfer and Manipulation project (MSSTM). Organised in two phases, the project will re-evaluate in phase 1 the output of the previous study in the light of new inputs (e.g. addition of a rover) and investigate further the architectures and systems involved in the sample transfer chain while identifying the critical technologies. The second phase of the project will concentrate on the prototyping of a number of these key technologies with the goal of providing an end-to end validation of the surface sample transfer concept.
Applications of flight control system methods to an advanced combat rotorcraft
NASA Technical Reports Server (NTRS)
Tischler, Mark B.; Fletcher, Jay W.; Morris, Patrick M.; Tucker, George T.
1989-01-01
Advanced flight control system design, analysis, and testing methodologies developed at the Ames Research Center are applied in an analytical and flight test evaluation of the Advanced Digital Optical Control System (ADOCS) demonstrator. The primary objectives are to describe the knowledge gained about the implications of digital flight control system design for rotorcraft, and to illustrate the analysis of the resulting handling-qualities in the context of the proposed new handling-qualities specification for rotorcraft. Topics covered in-depth are digital flight control design and analysis methods, flight testing techniques, ADOCS handling-qualities evaluation results, and correlation of flight test results with analytical models and the proposed handling-qualities specification. The evaluation of the ADOCS demonstrator indicates desirable response characteristics based on equivalent damping and frequency, but undersirably large effective time-delays (exceeding 240 m sec in all axes). Piloted handling-qualities are found to be desirable or adequate for all low, medium, and high pilot gain tasks; but handling-qualities are inadequate for ultra-high gain tasks such as slope and running landings.
In vivo crystallography at X-ray free-electron lasers: the next generation of structural biology?
Gallat, François-Xavier; Matsugaki, Naohiro; Coussens, Nathan P; Yagi, Koichiro J; Boudes, Marion; Higashi, Tetsuya; Tsuji, Daisuke; Tatano, Yutaka; Suzuki, Mamoru; Mizohata, Eiichi; Tono, Kensuke; Joti, Yasumasa; Kameshima, Takashi; Park, Jaehyun; Song, Changyong; Hatsui, Takaki; Yabashi, Makina; Nango, Eriko; Itoh, Kohji; Coulibaly, Fasséli; Tobe, Stephen; Ramaswamy, S; Stay, Barbara; Iwata, So; Chavas, Leonard M G
2014-07-17
The serendipitous discovery of the spontaneous growth of protein crystals inside cells has opened the field of crystallography to chemically unmodified samples directly available from their natural environment. On the one hand, through in vivo crystallography, protocols for protein crystal preparation can be highly simplified, although the technique suffers from difficulties in sampling, particularly in the extraction of the crystals from the cells partly due to their small sizes. On the other hand, the extremely intense X-ray pulses emerging from X-ray free-electron laser (XFEL) sources, along with the appearance of serial femtosecond crystallography (SFX) is a milestone for radiation damage-free protein structural studies but requires micrometre-size crystals. The combination of SFX with in vivo crystallography has the potential to boost the applicability of these techniques, eventually bringing the field to the point where in vitro sample manipulations will no longer be required, and direct imaging of the crystals from within the cells will be achievable. To fully appreciate the diverse aspects of sample characterization, handling and analysis, SFX experiments at the Japanese SPring-8 angstrom compact free-electron laser were scheduled on various types of in vivo grown crystals. The first experiments have demonstrated the feasibility of the approach and suggest that future in vivo crystallography applications at XFELs will be another alternative to nano-crystallography. © 2014 The Author(s) Published by the Royal Society. All rights reserved.
Creation of 0.10-cm-1 resolution quantitative infrared spectral libraries for gas samples
NASA Astrophysics Data System (ADS)
Sharpe, Steven W.; Sams, Robert L.; Johnson, Timothy J.; Chu, Pamela M.; Rhoderick, George C.; Guenther, Franklin R.
2002-02-01
The National Institute of Standards and Technology (NIST) and the Pacific Northwest National Laboratory (PNNL) are independently creating quantitative, approximately 0.10 cm-1 resolution, infrared spectral libraries of vapor phase compounds. The NIST library will consist of approximately 100 vapor phase spectra of volatile hazardous air pollutants (HAPs) and suspected greenhouse gases. The PNNL library will consist of approximately 400 vapor phase spectra associated with DOE's remediation mission. A critical part of creating and validating any quantitative work involves independent verification based on inter-laboratory comparisons. The two laboratories use significantly different sample preparation and handling techniques. NIST uses gravimetric dilution and a continuous flowing sample while PNNL uses partial pressure dilution and a static sample. Agreement is generally found to be within the statistical uncertainties of the Beer's law fit and less than 3 percent of the total integrated band areas for the 4 chemicals used in this comparison. There does appear to be a small systematic difference between the PNNL and NIST data, however. Possible sources of the systematic difference will be discussed as well as technical details concerning the sample preparation and the procedures for overcoming instrumental artifacts.
Barriada-Pereira, Mercedes; Iglesias-García, Iván; González-Castro, María J; Muniategui-Lorenzo, Soledad; López-Mahía, Purificación; Prada-Rodríguez, Darío
2008-01-01
This paper describes a comparative study of 2 extraction methods, pressurized liquid extraction (PLE) and microwave-assisted extraction (MAE), for the determination of organochlorine pesticides (OCPs) in fish muscle samples. In both cases, samples were extracted with hexane-acetone (50 + 50), and the extracts were purified by solid-phase extraction using a carbon cartridge as the adsorbent. Pesticides were eluted with hexane-ethyl acetate (80 + 20) and determined by gas chromatography with electron-capture detection. Both methods demonstrated good linearity over the range studied (0.005-0.100 microg/mL). Detection limits ranged from 0.029 to 0.295 mg/kg for PLE and from 0.003 to 0.054 mg/kg for MAE. For most of the pesticides, analytical recoveries with both methods were between 80 and 120%, and the relative standard deviations were < 10%. The proposed methods were shown to be powerful techniques for the extraction of OCPs from fish muscle samples. Although good recovery rates were obtained with both extraction methods, MAE provided advantages with regard to sample handling, cost, analysis time, and solvent consumption. Acceptable validation parameters were obtained although MAE was shown to be more sensitive than PLE.
Milne, A D; Brousseau, P A; Brousseau, C A
2014-12-01
A bench-top study was performed to assess the effects of different laryngoscope handles on the light intensity delivered from disposable metal or plastic laryngoscope blades. The light intensity from both the handle light sources themselves and the combined handle and laryngoscope blade sets was measured using a custom-designed testing system and light meter. Five samples of each disposable blade type were tested and compared with a standard re-usable stainless steel blade using three different handle/light sources (Vital Signs LED, Heine 2.5 V Xenon and 3.5 V Xenon). The light intensity delivered by the disposable blades ranged from 790 to 3846 lux for the different handle types. Overall, the 3.5 V Heine handle delivered the highest light output (p < 0.007) in comparison with the other handles. For the disposable blades, the overall light output was significantly higher from the plastic than the metal blades (p < 0.001). © 2014 The Association of Anaesthetists of Great Britain and Ireland.
Latysh, Natalie E.; Wetherbee, Gregory A.
2005-01-01
The U.S. Geological Survey, Branch of Quality Systems, operates the external quality-assurance programs for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN). Beginning in 1978, six different programs have been implemented?the intersite-comparison program, the blind-audit program, the sample-handling evaluation program, the field-audit program, the interlaboratory-comparison program, and the collocated-sampler program. Each program was designed to measure error contributed by specific components in the data-collection process. The intersite-comparison program, which was discontinued in 2004, was designed to assess the accuracy and reliability of field pH and specific-conductance measurements made by site operators. The blind-audit and sample-handling evaluation programs, which also were discontinued in 2002 and 2004, respectively, assessed contamination that may result from sampling equipment and routine handling and processing of the wet-deposition samples. The field-audit program assesses the effects of sample handling, processing, and field exposure. The interlaboratory-comparison program evaluates bias and precision of analytical results produced by the contract laboratory for NADP, the Illinois State Water Survey, Central Analytical Laboratory, and compares its performance with the performance of international laboratories. The collocated-sampler program assesses the overall precision of wet-deposition data collected by NADP/NTN. This report documents historical operations and the operating procedures for each of these external quality-assurance programs. USGS quality-assurance information allows NADP/NTN data users to discern between actual environmental trends and inherent measurement variability.
NASA Astrophysics Data System (ADS)
Sun, Chengjun; Jiang, Fenghua; Gao, Wei; Li, Xiaoyun; Yu, Yanzhen; Yin, Xiaofei; Wang, Yong; Ding, Haibing
2017-01-01
Detection of sulfur-oxidizing bacteria has largely been dependent on targeted gene sequencing technology or traditional cell cultivation, which usually takes from days to months to carry out. This clearly does not meet the requirements of analysis for time-sensitive samples and/or complicated environmental samples. Since energy-dispersive X-ray spectrometry (EDS) can be used to simultaneously detect multiple elements in a sample, including sulfur, with minimal sample treatment, this technology was applied to detect sulfur-oxidizing bacteria using their high sulfur content within the cell. This article describes the application of scanning electron microscopy imaging coupled with EDS mapping for quick detection of sulfur oxidizers in contaminated environmental water samples, with minimal sample handling. Scanning electron microscopy imaging revealed the existence of dense granules within the bacterial cells, while EDS identified large amounts of sulfur within them. EDS mapping localized the sulfur to these granules. Subsequent 16S rRNA gene sequencing showed that the bacteria detected in our samples belonged to the genus Chromatium, which are sulfur oxidizers. Thus, EDS mapping made it possible to identify sulfur oxidizers in environmental samples based on localized sulfur within their cells, within a short time (within 24 h of sampling). This technique has wide ranging applications for detection of sulfur bacteria in environmental water samples.
Study on Handing Process and Quality Degradation of Oil Palm Fresh Fruit Bunches (FFB)
NASA Astrophysics Data System (ADS)
Mat Sharif, Zainon Binti; Taib, Norhasnina Binti Mohd; Yusof, Mohd Sallehuddin Bin; Rahim, Mohammad Zulafif Bin; Tobi, Abdul Latif Bin Mohd; Othman, Mohd Syafiq Bin
2017-05-01
The main objective of this study is to determine the relationship between quality of oil palm fresh fruit bunches (FFB) and handling processes. The study employs exploratory and descriptive design, with quantitative approach and purposive sampling using self-administrated questionnaires, were obtained from 30 smallholder respondents from the Southern Region, Peninsular Malaysia. The study reveals that there was a convincing relationship between quality of oil palm fresh fruit bunches (FFB) and handling processes. The main handling process factors influencing quality of oil palm fresh fruit bunches (FFB) were harvesting activity and handling at the plantation area. As a result, it can be deduced that the handling process factors variable explains 82.80% of the variance that reflects the quality of oil palm fresh fruit bunches (FFB). The overall findings reveal that the handling process factors do play a significant role in the quality of oil palm fresh fruit bunches (FFB).
Pullar, Juliet M.; Carr, Anitra C.
2018-01-01
Vitamin C (ascorbate) is the major water-soluble antioxidant in plasma and its oxidation to dehydroascorbic acid (DHA) has been proposed as a marker of oxidative stress in vivo. However, controversy exists in the literature around the amount of DHA detected in blood samples collected from various patient cohorts. In this study, we report on DHA concentrations in a selection of different clinical cohorts (diabetes, pneumonia, cancer, and critically ill). All clinical samples were collected into EDTA anticoagulant tubes and processed at 4 °C prior to storage at −80 °C for subsequent analysis by HPLC with electrochemical detection. We also investigated the effects of different handling and processing conditions on short-term and long-term ascorbate and DHA stability in vitro and in whole blood and plasma samples. These conditions included metal chelation, anticoagulants (EDTA and heparin), and processing temperatures (ice, 4 °C and room temperature). Analysis of our clinical cohorts indicated very low to negligible DHA concentrations. Samples exhibiting haemolysis contained significantly higher concentrations of DHA. Metal chelation inhibited oxidation of vitamin C in vitro, confirming the involvement of contaminating metal ions. Although EDTA is an effective metal chelator, complexes with transition metal ions are still redox active, thus its use as an anticoagulant can facilitate metal ion-dependent oxidation of vitamin C in whole blood and plasma. Handling and processing blood samples on ice (or at 4 °C) delayed oxidation of vitamin C by a number of hours. A review of the literature regarding DHA concentrations in clinical cohorts highlighted the fact that studies using colourimetric or fluorometric assays reported significantly higher concentrations of DHA compared to those using HPLC with electrochemical detection. In conclusion, careful handling and processing of samples, combined with appropriate analysis, is crucial for accurate determination of ascorbate and DHA in clinical samples. PMID:29439480
The sample handling system for the Mars Icebreaker Life mission: from dirt to data.
Davé, Arwen; Thompson, Sarah J; McKay, Christopher P; Stoker, Carol R; Zacny, Kris; Paulsen, Gale; Mellerowicz, Bolek; Glass, Brian J; Willson, David; Bonaccorsi, Rosalba; Rask, Jon
2013-04-01
The Mars Icebreaker Life mission will search for subsurface life on Mars. It consists of three payload elements: a drill to retrieve soil samples from approximately 1 m below the surface, a robotic sample handling system to deliver the sample from the drill to the instruments, and the instruments themselves. This paper will discuss the robotic sample handling system. Collecting samples from ice-rich soils on Mars in search of life presents two challenges: protection of that icy soil--considered a "special region" with respect to planetary protection--from contamination from Earth, and delivery of the icy, sticky soil to spacecraft instruments. We present a sampling device that meets these challenges. We built a prototype system and tested it at martian pressure, drilling into ice-cemented soil, collecting cuttings, and transferring them to the inlet port of the SOLID2 life-detection instrument. The tests successfully demonstrated that the Icebreaker drill, sample handling system, and life-detection instrument can collectively operate in these conditions and produce science data that can be delivered via telemetry--from dirt to data. Our results also demonstrate the feasibility of using an air gap to prevent forward contamination. We define a set of six analog soils for testing over a range of soil cohesion, from loose sand to basalt soil, with angles of repose of 27° and 39°, respectively. Particle size is a key determinant of jamming of mechanical parts by soil particles. Jamming occurs when the clearance between moving parts is equal in size to the most common particle size or equal to three of these particles together. Three particles acting together tend to form bridges and lead to clogging. Our experiments show that rotary-hammer action of the Icebreaker drill influences the particle size, typically reducing particle size by ≈ 100 μm.
Risk analysis with a fuzzy-logic approach of a complex installation
NASA Astrophysics Data System (ADS)
Peikert, Tim; Garbe, Heyno; Potthast, Stefan
2016-09-01
This paper introduces a procedural method based on fuzzy logic to analyze systematic the risk of an electronic system in an intentional electromagnetic environment (IEME). The method analyzes the susceptibility of a complex electronic installation with respect to intentional electromagnetic interference (IEMI). It combines the advantages of well-known techniques as fault tree analysis (FTA), electromagnetic topology (EMT) and Bayesian networks (BN) and extends the techniques with an approach to handle uncertainty. This approach uses fuzzy sets, membership functions and fuzzy logic to handle the uncertainty with probability functions and linguistic terms. The linguistic terms add to the risk analysis the knowledge from experts of the investigated system or environment.
An analytical approach for predicting pilot induced oscillations
NASA Technical Reports Server (NTRS)
Hess, R. A.
1981-01-01
The optimal control model (OCM) of the human pilot is applied to the study of aircraft handling qualities. Attention is focused primarily on longitudinal tasks. The modeling technique differs from previous applications of the OCM in that considerable effort is expended in simplifying the pilot/vehicle analysis. After briefly reviewing the OCM, a technique for modeling the pilot controlling higher order systems is introduced. Following this, a simple criterion or determining the susceptability of an aircraft to pilot induced oscillations (PIO) is formulated. Finally, a model-based metric for pilot rating prediction is discussed. The resulting modeling procedure provides a relatively simple, yet unified approach to the study of a variety of handling qualities problems.
Electrostatic sampling of trace DNA from clothing.
Zieger, Martin; Defaux, Priscille Merciani; Utz, Silvia
2016-05-01
During acts of physical aggression, offenders frequently come into contact with clothes of the victim, thereby leaving traces of DNA-bearing biological material on the garments. Since tape-lifting and swabbing, the currently established methods for non-destructive trace DNA sampling from clothing, both have their shortcomings in collection efficiency and handling, we thought about a new collection method for these challenging samples. Testing two readily available electrostatic devices for their potential to sample biological material from garments made of different fabrics, we found one of them, the electrostatic dust print lifter (DPL), to perform comparable to well-established sampling with wet cotton swabs. In simulated aggression scenarios, we had the same success rate for the establishment of single aggressor profiles, suitable for database submission, with both the DPL and wet swabbing. However, we lost a substantial amount of information with electrostatic sampling, since almost no mixed aggressor-victim profiles suitable for database entry could be established, compared to conventional swabbing. This study serves as a proof of principle for electrostatic DNA sampling from items of clothing. The technique still requires optimization before it might be used in real casework. But we are confident that in the future it could be an efficient and convenient contribution to the toolbox of forensic practitioners.
NASA Astrophysics Data System (ADS)
Szydzik, C.; Gavela, A. F.; Roccisano, J.; Herranz de Andrés, S.; Mitchell, A.; Lechuga, L. M.
2016-12-01
We present recent results on the realisation and demonstration of an integrated optofluidic lab-on-a-chip measurement system. The system consists of an integrated on-chip automated microfluidic fluid handling subsystem, coupled with bimodal nano-interferometer waveguide technology, and is applied in the context of detection of antibiotics in seawater. The bimodal waveguide (BMWG) is a highly sensitive label-free biosensor. Integration of complex microfluidic systems with bimodal waveguide technology enables on-chip sample handling and fluid processing capabilities and allows for significant automation of experimental processes. The on-chip fluid-handling subsystem is realised through the integration of pneumatically actuated elastomer pumps and valves, enabling high temporal resolution sample and reagent delivery and facilitating multiplexed detection processes.
Zhang, Jie; Wei, Shimin; Ayres, David W; Smith, Harold T; Tse, Francis L S
2011-09-01
Although it is well known that automation can provide significant improvement in the efficiency of biological sample preparation in quantitative LC-MS/MS analysis, it has not been widely implemented in bioanalytical laboratories throughout the industry. This can be attributed to the lack of a sound strategy and practical procedures in working with robotic liquid-handling systems. Several comprehensive automation assisted procedures for biological sample preparation and method validation were developed and qualified using two types of Hamilton Microlab liquid-handling robots. The procedures developed were generic, user-friendly and covered the majority of steps involved in routine sample preparation and method validation. Generic automation procedures were established as a practical approach to widely implement automation into the routine bioanalysis of samples in support of drug-development programs.
An instrument to aid tubal sterilization by laparoscopy.
Siegler, A M
1972-05-01
A single-handled instrument, developed by Siegler for his two-incision technique, has broad biopsy capability. The shaft and handle are insulated to protect the operator from shock; the jaws rotate independently from the handle position; an O-ring seal in the cannula eliminates the need for external sealing devices for carbon dioxide maintenance; and either the cutting or coagulation power may be applied. The biopsy instrument can coagulate and biopsy both tubes without removing the forceps after treating one side since the jaws are large enough to accommodate both segments. The instrument is manufactured by the American Cystoscope Makers, Inc., Pelham Manor, New York.
Bonizzi, I; Buffoni, J N; Feligini, M; Enne, G
2009-10-01
To assess the bacterial biodiversity level in bovine raw milk used to produce Fontina, a Protected Designation of Origin cheese manufactured at high-altitude pastures and in valleys of Valle d'Aosta region (North-western Italian Alps) without any starters. To study the relation between microbial composition and pasture altitude, in order to distinguish high-altitude milk against valley and lowland milk. The microflora from milks sampled at different alpine pasture, valley and lowland farms were fingerprinted by PCR of the 16S-23S intergenic transcribed spacers (ITS-PCR). The resulting band patterns were analysed by generalized multivariate statistical techniques to handle discrete (band presence-absence) and continuous (altitude) information. The fingerprints featured numerous bands and marked variability indicating complex, differentiated bacterial communities. Alpine pasture milks were distinguished from lowland ones by cluster analysis, while this technique less clearly discriminated alpine pasture and valley samples. Generalized principal component analysis and clustering-after-ordination enabled a more effective distinction of alpine pasture, valley and lowland samples. Alpine raw milks for Fontina production contain highly diverse bacterial communities, the composition of which is related to the altitude of the pasture where milk was produced. This research may provide analytical support to the important issue represented by the authentication of the geographical origin of alpine milk productions.
Quality assurance in the pre-analytical phase of human urine samples by (1)H NMR spectroscopy.
Budde, Kathrin; Gök, Ömer-Necmi; Pietzner, Maik; Meisinger, Christine; Leitzmann, Michael; Nauck, Matthias; Köttgen, Anna; Friedrich, Nele
2016-01-01
Metabolomic approaches investigate changes in metabolite profiles, which may reflect changes in metabolic pathways and provide information correlated with a specific biological process or pathophysiology. High-resolution (1)H NMR spectroscopy is used to identify metabolites in biofluids and tissue samples qualitatively and quantitatively. This pre-analytical study evaluated the effects of storage time and temperature on (1)H NMR spectra from human urine in two settings. Firstly, to evaluate short time effects probably due to acute delay in sample handling and secondly, the effect of prolonged storage up to one month to find markers of sample miss-handling. A number of statistical procedures were used to assess the differences between samples stored under different conditions, including Projection to Latent Structure Discriminant Analysis (PLS-DA), non-parametric testing as well as mixed effect linear regression analysis. The results indicate that human urine samples can be stored at 10 °C for 24 h or at -80 °C for 1 month, as no relevant changes in (1)H NMR fingerprints were observed during these time periods and temperature conditions. However, some metabolites most likely of microbial origin showed alterations during prolonged storage but without facilitating classification. In conclusion, the presented protocol for urine sample handling and semi-automatic metabolite quantification is suitable for large-scale epidemiological studies. Copyright © 2015 Elsevier Inc. All rights reserved.
Environmental contamination with methotrexate in Canadian community pharmacies.
Merger, Delphine; Tanguay, Cynthia; Langlois, Éric; Lefebvre, Michel; Bussières, Jean-François
2013-01-01
To evaluate environmental contamination with methotrexate, cyclophosphamide, and ifosfamide in Quebec, Canada, community pharmacies and to describe hazardous drug handling practices in these pharmacies. Three standardized sites were sampled in each participating community pharmacy. Samples were analyzed for the presence of cyclophosphamide, ifosfamide, and methotrexate by high-performance liquid chromatography tandem mass spectrometry. The limits of detection were 0.10, 0.12, and 0.41 ng/mL for cyclophosphamide, ifosfamide, and methotrexate, respectively. Nine working practices were assessed. 20 community pharmacies participated in the study, and 60 samples were analyzed. No traces of cyclophosphamide or ifosfamide were detected. Traces of methotrexate were found in 12 of 20 pharmacies (60%). Of the 20 pharmacies, 8 (40%) had a storage space reserved for hazardous drugs and none had a preparation area reserved for handling methotrexate tablets. All of the participating community pharmacies had a tablet counter reserved for the handling of hazardous drugs, and all pharmacies cleaned their tablet counter reserved for handling hazardous drugs after use. None of the pharmacies cut or crushed methotrexate tablets. The growing number of hazardous drugs represents a challenge for community pharmacies. Community pharmacists must be made aware of their presence and the need to comply with personal protection measures to reduce staff occupational exposure to hazardous drugs.
77 FR 48130 - Marine Mammals; File No. 17152
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-13
... harbor seals are requested over the duration of the permit. Each year, up to 2,500 northern elephant seals (Mirounga angustirostris) will be handled for marking without capture; up to 100 elephant seals will be handled for swab sampling without capture; up to 150 elephant seals will be captured, marked...
Application research of 3D additive manufacturing technology in the nail shell
NASA Astrophysics Data System (ADS)
Xiao, Shanhua; Yan, Ruiqiang; Song, Ning
2018-04-01
Based on the analysis of hierarchical slicing algorithm, 3D scanning of enterprise product nailing handle case file is carried out, point cloud data processing is performed on the source file, and the surface modeling and innovative design of nail handling handle case are completed. Using MakerBot Replicator2X-based 3D printer for layered 3D print samples, for the new nail product development to provide reverse modeling and rapid prototyping technical support.
Multitarget-multisensor management for decentralized sensor networks
NASA Astrophysics Data System (ADS)
Tharmarasa, R.; Kirubarajan, T.; Sinha, A.; Hernandez, M. L.
2006-05-01
In this paper, we consider the problem of sensor resource management in decentralized tracking systems. Due to the availability of cheap sensors, it is possible to use a large number of sensors and a few fusion centers (FCs) to monitor a large surveillance region. Even though a large number of sensors are available, due to frequency, power and other physical limitations, only a few of them can be active at any one time. The problem is then to select sensor subsets that should be used by each FC at each sampling time in order to optimize the tracking performance subject to their operational constraints. In a recent paper, we proposed an algorithm to handle the above issues for joint detection and tracking, without using simplistic clustering techniques that are standard in the literature. However, in that paper, a hierarchical architecture with feedback at every sampling time was considered, and the sensor management was performed only at a central fusion center (CFC). However, in general, it is not possible to communicate with the CFC at every sampling time, and in many cases there may not even be a CFC. Sometimes, communication between CFC and local fusion centers might fail as well. Therefore performing sensor management only at the CFC is not viable in most networks. In this paper, we consider an architecture in which there is no CFC, each FC communicates only with the neighboring FCs, and communications are restricted. In this case, each FC has to decide which sensors are to be used by itself at each measurement time step. We propose an efficient algorithm to handle the above problem in real time. Simulation results illustrating the performance of the proposed algorithm are also presented.
Mars Sample Handling Protocol Workshop Series: Workshop 2a (Sterilization)
NASA Technical Reports Server (NTRS)
Rummel, John D. (Editor); Brunch, Carl W. (Editor); Setlow, Richard B. (Editor); DeVincenzi, Donald L. (Technical Monitor)
2001-01-01
The Space Studies Board of the National Research Council provided a series of recommendations to NASA on planetary protection requirements for future Mars sample return missions. One of the Board's key findings suggested, although current evidence of the martian surface suggests that life as we know it would not tolerate the planet's harsh environment, there remain 'plausible scenarios for extant microbial life on Mars.' Based on this conclusion, all samples returned from Mars should be considered potentially hazardous until it has been demonstrated that they are not. In response to the National Research Council's findings and recommendations, NASA has undertaken a series of workshops to address issues regarding NASA's proposed sample return missions. Work was previously undertaken at the Mars Sample Handling and Protocol Workshop 1 (March 2000) to formulate recommendations on effective methods for life detection and/or biohazard testing on returned samples. The NASA Planetary Protection Officer convened the Mars Sample Sterilization Workshop, the third in the Mars Sample Handling Protocol Workshop Series, on November 28-30, 2000 at the Holiday Inn Rosslyn Westpark, Arlington, Virginia. Because of the short timeframe between this Workshop and the second Workshop in the Series, which was convened in October 2000 in Bethesda, Maryland, they were developed in parallel, so the Sterilization Workshop and its report have therefore been designated as '2a'). The focus of Workshop 2a was to make recommendations for effective sterilization procedures for all phases of Mars sample return missions, and to answer the question of whether we can sterilize samples in such a way that the geological characteristics of the samples are not significantly altered.
A Draft Protocol for Detecting Possible Biohazards in Martian Samples Returned to Earth
NASA Technical Reports Server (NTRS)
Viso, M.; DeVincenzi, D. L.; Race, M. S.; Schad, P. J.; Stabekis, P. D.; Acevedo, S. E.; Rummel, J. D.
2002-01-01
In preparation for missions to Mars that will involve the return of samples, it is necessary to prepare for the safe receiving, handling, testing, distributing, and archiving of martian materials here on Earth. Previous groups and committees have studied selected aspects of sample return activities, but a specific protocol for handling and testing of returned -=1 samples from Mars remained to be developed. To refine the requirements for Mars sample hazard testing and to develop criteria for the subsequent release of sample materials from precautionary containment, NASA Planetary Protection Officer, working in collaboration with CNES, convened a series of workshops to produce a Protocol by which returned martian sample materials could be assessed for biological hazards and examined for evidence of life (extant or extinct), while safeguarding the samples from possible terrestrial contamination. The Draft Protocol was then reviewed by an Oversight and Review Committee formed specifically for that purpose and composed of senior scientists. In order to preserve the scientific value of returned martian samples under safe conditions, while avoiding false indications of life within the samples, the Sample Receiving Facility (SRF) is required to allow handling and processing of the Mars samples to prevent their terrestrial contamination while maintaining strict biological containment. It is anticipated that samples will be able to be shipped among appropriate containment facilities wherever necessary, under procedures developed in cooperation with international appropriate institutions. The SRF will need to provide different types of laboratory environments for carrying out, beyond sample description and curation, the various aspects of the protocol: Physical/Chemical analysis, Life Detection testing, and Biohazard testing. The main principle of these tests will be described and the criteria for release will be discussed, as well as the requirements for the SRF and its personnel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yinfa, Ma.
Thin-layer chromatography (TLC) is a broadly applicable separation technique. It offers many advantages over high performance liquid chromatography (HPLC), such as easily adapted for two-dimensional separation, for whole-column'' detection and for handling multiple samples, etc. However, due to its draggy development of detection techniques comparing with HPLC, TLC has not received the attention it deserves. Therefore, exploring new detection techniques is very important to the development of TLC. It is the principal of this dissertation to present a new detection method for TLC -- indirect fluorometric detection method. This detection technique is universal sensitive, nondestructive, and simple. This will bemore » described in detail from Sections 1 through Section 5. Section 1 and 3 describe the indirect fluorometric detection of anions and nonelectrolytes in TLC. In Section 2, a detection method for cations based on fluorescence quenching of ethidium bromide is presented. In Section 4, a simple and interesting TLC experiment is designed, three different fluorescence detection principles are used for the determination of caffeine, saccharin and sodium benzoate in beverages. A laser-based indirect fluorometric detection technique in TLC is developed in Section 5. Section 6 is totally different from Sections 1 through 5. An ultrasonic effect on the separation of DNA fragments in agarose gel electrophoresis is investigated. 262 refs.« less
Thiel, M; Bossart, W; Bernauer, W
1997-01-01
BACKGROUND—For epidemiological and therapeutic reasons early diagnosis of superficial viral infections is crucial. Conventional microbiological techniques are expensive, time consuming, and not sufficiently sensitive. In this study impression cytology techniques were evaluated to analyse their diagnostic potential in viral infections of the ocular surface. METHOD—A Biopore membrane device instead of the original impression cytology technique was used to allow better quality and handling of the specimens. The impressions were processed, using monoclonal antibodies and immunoperoxidase or immunofluorescence techniques to assess the presence of herpes simplex virus, varicella zoster virus, or adenovirus antigens. Ocular surface specimens from healthy individuals (n=10) and from patients with suspected viral surface disease (n=19) were studied. Infected and non-infected cell cultures served as controls. RESULTS—This modified technique of impression cytology allowed the collection of large conjunctival and corneal epithelial cell layers with excellent morphology. Immunocytological staining of these samples provided diagnostic results for all three viruses in patients with viral surface disease. CONCLUSIONS—The use of Biopore membrane devices for the collection of ocular surface epithelia offers new diagnostic possibilities for external eye diseases. Immunopathological methods that are applied directly on these membrane devices can provide virological results within 1-4 hours. This contributes considerably to the clinical management of patients with infectious diseases of the ocular surface. PMID:9505824
Advanced techniques and technology for efficient data storage, access, and transfer
NASA Technical Reports Server (NTRS)
Rice, Robert F.; Miller, Warner
1991-01-01
Advanced techniques for efficiently representing most forms of data are being implemented in practical hardware and software form through the joint efforts of three NASA centers. These techniques adapt to local statistical variations to continually provide near optimum code efficiency when representing data without error. Demonstrated in several earlier space applications, these techniques are the basis of initial NASA data compression standards specifications. Since the techniques clearly apply to most NASA science data, NASA invested in the development of both hardware and software implementations for general use. This investment includes high-speed single-chip very large scale integration (VLSI) coding and decoding modules as well as machine-transferrable software routines. The hardware chips were tested in the laboratory at data rates as high as 700 Mbits/s. A coding module's definition includes a predictive preprocessing stage and a powerful adaptive coding stage. The function of the preprocessor is to optimally process incoming data into a standard form data source that the second stage can handle.The built-in preprocessor of the VLSI coder chips is ideal for high-speed sampled data applications such as imaging and high-quality audio, but additionally, the second stage adaptive coder can be used separately with any source that can be externally preprocessed into the 'standard form'. This generic functionality assures that the applicability of these techniques and their recent high-speed implementations should be equally broad outside of NASA.
Positioning an Interactive Telecourse in Business.
ERIC Educational Resources Information Center
Garland, Barbara C.; Schwinghammer, JoAnn K. L.
1987-01-01
The authors describe pedagogical techniques based on one and a half years of planning and executing the introduction of a graduate marketing management telecourse. They focus on issues of positioning strategy that arose during the introduction and on the pedagogical techniques that were used to handle them. (CH)
ERIC Educational Resources Information Center
Ohio State Univ., Columbus. Instructional Materials Lab.
This learner manual for rescuers covers the current techniques or practices required in the rescue service. The second of 10 modules contains 5 chapters: (1) patient care and handling techniques; (2) rescue carries and drags; (3) emergency vehicle operations; (4) self-contained breathing apparatus; and (5) protective clothing. Key points, an…
Efficient Power Network Analysis with Modeling of Inductive Effects
NASA Astrophysics Data System (ADS)
Zeng, Shan; Yu, Wenjian; Hong, Xianlong; Cheng, Chung-Kuan
In this paper, an efficient method is proposed to accurately analyze large-scale power/ground (P/G) networks, where inductive parasitics are modeled with the partial reluctance. The method is based on frequency-domain circuit analysis and the technique of vector fitting [14], and obtains the time-domain voltage response at given P/G nodes. The frequency-domain circuit equation including partial reluctances is derived, and then solved with the GMRES algorithm with rescaling, preconditioning and recycling techniques. With the merit of sparsified reluctance matrix and iterative solving techniques for the frequency-domain circuit equations, the proposed method is able to handle large-scale P/G networks with complete inductive modeling. Numerical results show that the proposed method is orders of magnitude faster than HSPICE, several times faster than INDUCTWISE [4], and capable of handling the inductive P/G structures with more than 100, 000 wire segments.
Knowledge-based geographic information systems (KBGIS): New analytic and data management tools
Albert, T.M.
1988-01-01
In its simplest form, a geographic information system (GIS) may be viewed as a data base management system in which most of the data are spatially indexed, and upon which sets of procedures operate to answer queries about spatial entities represented in the data base. Utilization of artificial intelligence (AI) techniques can enhance greatly the capabilities of a GIS, particularly in handling very large, diverse data bases involved in the earth sciences. A KBGIS has been developed by the U.S. Geological Survey which incorporates AI techniques such as learning, expert systems, new data representation, and more. The system, which will be developed further and applied, is a prototype of the next generation of GIS's, an intelligent GIS, as well as an example of a general-purpose intelligent data handling system. The paper provides a description of KBGIS and its application, as well as the AI techniques involved. ?? 1988 International Association for Mathematical Geology.
Identification of geometric faces in hand-sketched 3D objects containing curved lines
NASA Astrophysics Data System (ADS)
El-Sayed, Ahmed M.; Wahdan, A. A.; Youssif, Aliaa A. A.
2017-07-01
The reconstruction of 3D objects from 2D line drawings is regarded as one of the key topics in the field of computer vision. The ongoing research is mainly focusing on the reconstruction of 3D objects that are mapped only from 2D straight lines, and that are symmetric in nature. Commonly, this approach only produces basic and simple shapes that are mostly flat or rather polygonized in nature, which is normally attributed to inability to handle curves. To overcome the above-mentioned limitations, a technique capable of handling non-symmetric drawings that encompass curves is considered. This paper discusses a novel technique that can be used to reconstruct 3D objects containing curved lines. In addition, it highlights an application that has been developed in accordance with the suggested technique that can convert a freehand sketch to a 3D shape using a mobile phone.
Microfluidic devices for sample preparation and rapid detection of foodborne pathogens.
Kant, Krishna; Shahbazi, Mohammad-Ali; Dave, Vivek Priy; Ngo, Tien Anh; Chidambara, Vinayaka Aaydha; Than, Linh Quyen; Bang, Dang Duong; Wolff, Anders
2018-03-10
Rapid detection of foodborne pathogens at an early stage is imperative for preventing the outbreak of foodborne diseases, known as serious threats to human health. Conventional bacterial culturing methods for foodborne pathogen detection are time consuming, laborious, and with poor pathogen diagnosis competences. This has prompted researchers to call the current status of detection approaches into question and leverage new technologies for superior pathogen sensing outcomes. Novel strategies mainly rely on incorporating all the steps from sample preparation to detection in miniaturized devices for online monitoring of pathogens with high accuracy and sensitivity in a time-saving and cost effective manner. Lab on chip is a blooming area in diagnosis, which exploits different mechanical and biological techniques to detect very low concentrations of pathogens in food samples. This is achieved through streamlining the sample handling and concentrating procedures, which will subsequently reduce human errors and enhance the accuracy of the sensing methods. Integration of sample preparation techniques into these devices can effectively minimize the impact of complex food matrix on pathogen diagnosis and improve the limit of detections. Integration of pathogen capturing bio-receptors on microfluidic devices is a crucial step, which can facilitate recognition abilities in harsh chemical and physical conditions, offering a great commercial benefit to the food-manufacturing sector. This article reviews recent advances in current state-of-the-art of sample preparation and concentration from food matrices with focus on bacterial capturing methods and sensing technologies, along with their advantages and limitations when integrated into microfluidic devices for online rapid detection of pathogens in foods and food production line. Copyright © 2018. Published by Elsevier Inc.
Do they practise what we teach? A survey of manual handling practice amongst student nurses.
Swain, Jane; Pufahl, Eric; R Williamson, Graham
2003-03-01
Experience of training students of nursing in manual handling suggested that they did not practise the techniques they had been taught. A search of the literature revealed that there was indeed a theory-practice gap. The aim of the project was to answer three questions: do students know what they should be doing, do they do what they should be doing, and if not, why not. A survey design was used, with questionnaires designed specifically for the study. Self report questionnaires were distributed to students of nursing (n = 148) on the adult branch in one higher education institution in England. One hundred and thirty-nine completed questionnaires were returned. Results showed that students' knowledge of whether particular techniques were 'recommended' was fair. They indicated however, that they were frequently unable to use recommended techniques in practice. The most frequent explanation given was the influence of other nurses. Results of this small study indicated that male students and younger students were more susceptible to socialization into poor ward practice than others. Other reasons for not using recommended techniques were unavailability of manual handling aids, lack of time and patient needs. The complexity of relationships within the nursing team emerged, with students ever aware of the impression they were making with regard to their assessment of practice, and their need to be accepted as a member of the team. Changes to training are suggested, to help reduce the theory-practice gap.
Mars Sample Handling Protocol Workshop Series: Workshop 2
NASA Technical Reports Server (NTRS)
Rummel, John D. (Editor); Acevedo, Sara E. (Editor); Kovacs, Gregory T. A. (Editor); Race, Margaret S. (Editor); DeVincenzi, Donald L. (Technical Monitor)
2001-01-01
Numerous NASA reports and studies have identified Planetary Protection (PP) as an important part of any Mars sample return mission. The mission architecture, hardware, on-board experiments, and related activities must be designed in ways that prevent both forward- and back-contamination and also ensure maximal return of scientific information. A key element of any PP effort for sample return missions is the development of guidelines for containment and analysis of returned sample(s). As part of that effort, NASA and the Space Studies Board (SSB) of the National Research Council (NRC) have each assembled experts from a wide range of scientific fields to identify and discuss issues pertinent to sample return. In 1997, the SSB released its report on recommendations for handling and testing of returned Mars samples. In particular, the NRC recommended that: a) samples returned from Mars by spacecraft should be contained and treated as potentially hazardous until proven otherwise, and b) rigorous physical, chemical, and biological analyses [should] confirm that there is no indication of the presence of any exogenous biological entity. Also in 1997, a Mars Sample Quarantine Protocol workshop was convened at NASA Ames Research Center to deal with three specific aspects of the initial handling of a returned Mars sample: 1) biocontainment, to prevent 'uncontrolled release' of sample material into the terrestrial environment; 2) life detection, to examine the sample for evidence of organisms; and 3) biohazard testing, to determine if the sample poses any threat to terrestrial life forms and the Earth's biosphere. In 1999, a study by NASA's Mars Sample Handling and Requirements Panel (MSHARP) addressed three other specific areas in anticipation of returning samples from Mars: 1) sample collection and transport back to Earth; 2) certification of the samples as non-hazardous; and 3) sample receiving, curation, and distribution. To further refine the requirements for sample hazard testing and the criteria for subsequent release of sample materials from quarantine, the NASA Planetary Protection Officer convened an additional series of workshops beginning in March 2000. The overall objective of these workshops was to develop comprehensive protocols to assess whether the returned materials contain any biological hazards, and to safeguard the purity of the samples from possible terrestrial contamination. This document is the report of the second Workshop in the Series. The information herein will ultimately be integrated into a final document reporting the proceedings of the entire Workshop Series along with additional information and recommendations.
Study of the formation of duricrusts on the martian surface and their effect on sampling equipment
NASA Astrophysics Data System (ADS)
Kömle, Norbert; Pitcher, Craig; Gao, Yang; Richter, Lutz
2017-01-01
The Powdered Sample Dosing and Distribution System (PSDDS) of the ExoMars rover will be required to handle and contain samples of Mars regolith for long periods of time. Cementation of the regolith, caused by water and salts in the soil, results in clumpy material and a duricrust layer forming on the surface. It is therefore possible that material residing in the sampling system may cement, and could potentially hinder its operation. There has yet to be an investigation into the formation of duricrusts under simulated Martian conditions, or how this may affect the performance of sample handling mechanisms. Therefore experiments have been performed to create a duricrust and to explore the cementation of Mars analogues, before performing a series of tests on a qualification model of the PSDDS under simulated Martian conditions. It was possible to create a consolidated crust of cemented material several millimetres deep, with the material below remaining powder-like. It was seen that due to the very low permeability of the Montmorillonite component material, diffusion of water through the material was quickly blocked, resulting in a sample with an inhomogeneous water content. Additionally, samples with a water mass content of 10% or higher would cement into a single solid piece. Finally, tests with the PSDDS revealed that samples with a water mass content of just 5% created small clumps with significant internal cohesion, blocking the sample funnels and preventing transportation of the material. These experiments have highlighted that the cementation of regolith in Martian conditions must be taken into consideration in the design of sample handling instruments.
NASA Astrophysics Data System (ADS)
Schrodt, Franziska; Shan, Hanhuai; Fazayeli, Farideh; Karpatne, Anuj; Kattge, Jens; Banerjee, Arindam; Reichstein, Markus; Reich, Peter
2013-04-01
With the advent of remotely sensed data and coordinated efforts to create global databases, the ecological community has progressively become more data-intensive. However, in contrast to other disciplines, statistical ways of handling these large data sets, especially the gaps which are inherent to them, are lacking. Widely used theoretical approaches, for example model averaging based on Akaike's information criterion (AIC), are sensitive to missing values. Yet, the most common way of handling sparse matrices - the deletion of cases with missing data (complete case analysis) - is known to severely reduce statistical power as well as inducing biased parameter estimates. In order to address these issues, we present novel approaches to gap filling in large ecological data sets using matrix factorization techniques. Factorization based matrix completion was developed in a recommender system context and has since been widely used to impute missing data in fields outside the ecological community. Here, we evaluate the effectiveness of probabilistic matrix factorization techniques for imputing missing data in ecological matrices using two imputation techniques. Hierarchical Probabilistic Matrix Factorization (HPMF) effectively incorporates hierarchical phylogenetic information (phylogenetic group, family, genus, species and individual plant) into the trait imputation. Advanced Hierarchical Probabilistic Matrix Factorization (aHPMF) on the other hand includes climate and soil information into the matrix factorization by regressing the environmental variables against residuals of the HPMF. One unique opportunity opened up by aHPMF is out-of-sample prediction, where traits can be predicted for specific species at locations different to those sampled in the past. This has potentially far-reaching consequences for the study of global-scale plant functional trait patterns. We test the accuracy and effectiveness of HPMF and aHPMF in filling sparse matrices, using the TRY database of plant functional traits (http://www.try-db.org). TRY is one of the largest global compilations of plant trait databases (750 traits of 1 million plants), encompassing data on morphological, anatomical, biochemical, phenological and physiological features of plants. However, despite of unprecedented coverage, the TRY database is still very sparse, severely limiting joint trait analyses. Plant traits are the key to understanding how plants as primary producers adjust to changes in environmental conditions and in turn influence them. Forming the basis for Dynamic Global Vegetation Models (DGVMs), plant traits are also fundamental in global change studies for predicting future ecosystem changes. It is thus imperative that missing data is imputed in as accurate and precise a way as possible. In this study, we show the advantages and disadvantages of applying probabilistic matrix factorization techniques in incorporating hierarchical and environmental information for the prediction of missing plant traits as compared to conventional imputation techniques such as the complete case and mean approaches. We will discuss the implications of using gap-filled data for global-scale studies of plant functional trait - environment relationship as opposed to the above-mentioned conventional techniques, using examples of out-of-sample predictions of foliar Nitrogen across several species' ranges and biomes.
Hoffer, Erica; Tabak, Arek; Shcherb, Inna; Wiener, Avi; Bentur, Yedidia
2005-01-01
A sampling protocol for biomonitoring of the volatile solvent methylene chloride (MeCl(2)) by analysis of urine from exposed workers was established. Storage temperature, sample volume in headspace vial (HSV), and time to sealing HSV on determination of MeCl(2) in urine were evaluated. MeCl(2) was analyzed by a solid-phase microextraction technique combined with gas chromatography. Volume of urine in HSV has no effect on MeCl(2) analysis. Delays of 30 and 60 min from collection of urine until sealing the HSV caused 14.47 +/- 6.98% and 26.17 +/- 9.57% decreases from baseline concentration, respectively. MeCl(2) concentration in spiked urine samples stored in sealed HSVs decreased on day 2 and then remained stable for 2 weeks. Refrigeration did not improve recovery although it seems to be associated with less variability. MeCl(2) in urine samples of seven exposed workers was in the range of 0.02-0.06 mg/L. Sampling of MeCl(2)-containing urine should include collection of urine in closed plastic bottles, transfer to HSV within 15 min, sealing and clamping of HSV within 15 s, and storage of HSV in refrigeration until analysis, but no longer than 2 weeks. Standard samples should be prepared on the day of test sample collection and handled under the same conditions.
NASA Technical Reports Server (NTRS)
Kearsley, A. T.; Westphal, A. J.; Stadermann, F. J.; Armes, S. P.; Ball, A. D.; Borg, J.; Bridges, J. C.; Brownlee, D. E.; Burchell, M. J.; Chater, R. J.;
2010-01-01
Impact ionisation detectors on a suite of spacecraft have shown the direction, velocity, flux and mass distribution of smaller ISP entering the Solar System. During the aphelion segments of the Stardust flight, a dedicated collector surface was oriented to intercept ISP of beta = 1, and returned to Earth in January 2006. In this paper we describe the probable appeareance and size of IS particle craters from initial results of experimental impacts and numerical simulation, explain how foils are being prepared and mounted for crater searching by automated acquisition of high magnification electron images (whilst avoiding contamination of the foils) and comment on appropriate analytical techniques for Preliminary Examination (PE).
NASA Technical Reports Server (NTRS)
1972-01-01
A terminal area simulation is described which permits analysis and synthesis of current and advanced air traffic management system configurations including ground and airborne instrumentation and new and modified aircraft characteristics. Ground elements in the simulation include navigation aids, surveillance radars, communication links, air-route structuring, ATC procedures, airport geometries and runway handling constraints. Airborne elements include traffic samples with individual aircraft performance and operating characteristics and aircraft navigation equipment. The simulation also contains algorithms for conflict detection, conflict resolution, sequencing and pilot-controller data links. The simulation model is used to determine the sensitivities of terminal area traffic flow, safety and congestion to aircraft performance characteristics, avionics systems, and other ATC elements.
Tavares, Anthony J; Noor, M Omair; Uddayasankar, Uvaraj; Krull, Ulrich J; Vannoy, Charles H
2014-01-01
Semiconductor quantum dots (QDs) have long served as integral components in signal transduction modalities such as Förster resonance energy transfer (FRET). The majority of bioanalytical methods using QDs for FRET-based techniques simply monitor binding-induced conformational changes. In more recent work, QDs have been incorporated into solid-phase support systems, such as microfluidic chips, to serve as physical platforms in the development of functional biosensors and bioprobes. Herein, we describe a simple strategy for the transduction of nucleic acid hybridization that combines a novel design method based on FRET with an electrokinetically controlled microfluidic technology, and that offers further potential for amelioration of sample-handling issues and for simplification of dynamic stringency control.
Perini, Matteo; Paolini, Mauro; Camin, Federica; Appendino, Giovanni; Vitulo, Francesca; De Combarieu, Eric; Sardone, Nicola; Martinelli, Ernesto Marco; Pace, Roberto
2018-04-22
Saw palmetto (Serenoa repens, SP) is the most expensive oil source of the pharmaceutical and healthfood market, and its high cost and recurrent shortages have spurred the development of designer blends of fatty acids to mimic its phytochemical profile and fraudulently comply with the current authentication assays. To detect this adulteration, the combined use of isotopic fingerprint and omic analysis has been investigated, using Principal Component Analysis (PCA) to handle the complex databases generated by these techniques and to identify the possible source of the adulterants. Surprisingly, the presence of fatty acids of animal origin turned out to be widespread in commercial samples of saw palmetto oil. Copyright © 2018 Elsevier B.V. All rights reserved.
Property measurements and solidification studies by electrostatic levitation.
Paradis, Paul-François; Yu, Jianding; Ishikawa, Takehiko; Yoda, Shinichi
2004-11-01
The National Space Development Agency of Japan has recently developed several electrostatic levitation furnaces and implemented new techniques and procedures for property measurement, solidification studies, and atomic structure research. In addition to the contamination-free environment for undercooled and liquid metals and semiconductors, the newly developed facilities possess the unique capabilities of handling ceramics and high vapor pressure materials, reducing processing time, and imaging high luminosity samples. These are exemplified in this paper with the successful processing of BaTiO(3). This allowed measurement of the density of high temperature solid, liquid, and undercooled phases. Furthermore, the material resulting from containerless solidification consisted of micrometer-size particles and a glass-like phase exhibiting a giant dielectric constant exceeding 100,000.
Bourne, L. B.; Milner, F. J. M.
1963-01-01
Polyester resins are being increasingly used in industry. These resins require the addition of catalysts and accelerators. The handling of polyester resin system materials may give rise to skin irritations, allergic reactions, and burns. The burns are probably due to styrene and organic peroxides. Atmospheric pollution from styrene and explosion and fire risks from organic peroxides must be prevented. Where dimethylaniline is used scrupulous cleanliness and no-touch technique must be enforced. Handling precautions are suggested. Images PMID:14014495
Analysis of CL-20 in environmental matrices: water and soil.
Larson, Steven L; Felt, Deborah R; Davis, Jeffrey L; Escalon, Lynn
2002-04-01
Analytical techniques for the detection of 2,4,6,8,10,12-hexanitro-2,4,6,8,10,12-hexaazatetracyclo(5.5.0.05,9.03,11)dodecane (CL-20) in water and soil are developed by adapting methods traditionally used for the analysis of nitroaromatics. CL-20 (a new explosives compound) is thermally labile, exhibits high polarity, and has low solubility in water. These constraints make the use of specialized sample handling, preparation, extraction, and analysis necessary. The ability to determine the concentrations of this new explosive compound in environmental matrices is helpful in understanding the environmental fate and effects of CL-20; understanding the physical, chemical, and biological fate of CL-20; and can be used in developing remediation technologies and determining their efficiency. The toxicity and mobility of new explosives in soil and groundwater are also of interest, and analytical techniques for quantitating CL-20 and its degradation products in soil and natural waters make these investigations possible.
Graphical Interface for the Study of Gas-Phase Reaction Kinetics: Cyclopentene Vapor Pyrolysis
NASA Astrophysics Data System (ADS)
Marcotte, Ronald E.; Wilson, Lenore D.
2001-06-01
The undergraduate laboratory experiment on the pyrolysis of gaseous cyclopentene has been modernized to improve safety, speed, and precision and to better reflect the current practice of physical chemistry. It now utilizes virtual instrument techniques to create a graphical computer interface for the collection and display of experimental data. An electronic pressure gauge has replaced the mercury manometer formerly needed in proximity to the 500 °C pyrolysis oven. Students have much better real-time information available to them and no longer require multiple lab periods to get rate constants and acceptable Arrhenius parameters. The time saved on manual data collection is used to give the students a tour of the computer interfacing hardware and software and a hands-on introduction to gas-phase reagent preparation using a research-grade high-vacuum system. This includes loading the sample, degassing it by the freeze-pump-thaw technique, handling liquid nitrogen and working through the logic necessary for each reconfiguration of the diffusion pump section and the submanifolds.
A statistical approach to combining multisource information in one-class classifiers
Simonson, Katherine M.; Derek West, R.; Hansen, Ross L.; ...
2017-06-08
A new method is introduced in this paper for combining information from multiple sources to support one-class classification. The contributing sources may represent measurements taken by different sensors of the same physical entity, repeated measurements by a single sensor, or numerous features computed from a single measured image or signal. The approach utilizes the theory of statistical hypothesis testing, and applies Fisher's technique for combining p-values, modified to handle nonindependent sources. Classifier outputs take the form of fused p-values, which may be used to gauge the consistency of unknown entities with one or more class hypotheses. The approach enables rigorousmore » assessment of classification uncertainties, and allows for traceability of classifier decisions back to the constituent sources, both of which are important for high-consequence decision support. Application of the technique is illustrated in two challenge problems, one for skin segmentation and the other for terrain labeling. Finally, the method is seen to be particularly effective for relatively small training samples.« less
A statistical approach to combining multisource information in one-class classifiers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simonson, Katherine M.; Derek West, R.; Hansen, Ross L.
A new method is introduced in this paper for combining information from multiple sources to support one-class classification. The contributing sources may represent measurements taken by different sensors of the same physical entity, repeated measurements by a single sensor, or numerous features computed from a single measured image or signal. The approach utilizes the theory of statistical hypothesis testing, and applies Fisher's technique for combining p-values, modified to handle nonindependent sources. Classifier outputs take the form of fused p-values, which may be used to gauge the consistency of unknown entities with one or more class hypotheses. The approach enables rigorousmore » assessment of classification uncertainties, and allows for traceability of classifier decisions back to the constituent sources, both of which are important for high-consequence decision support. Application of the technique is illustrated in two challenge problems, one for skin segmentation and the other for terrain labeling. Finally, the method is seen to be particularly effective for relatively small training samples.« less
Balanced mechanical resonator for powder handling device
NASA Technical Reports Server (NTRS)
Sarrazin, Philippe C. (Inventor); Brunner, Will M. (Inventor)
2012-01-01
A system incorporating a balanced mechanical resonator and a method for vibration of a sample composed of granular material to generate motion of a powder sample inside the sample holder for obtaining improved analysis statistics, without imparting vibration to the sample holder support.
7 CFR 800.99 - Checkweighing sacked grain.
Code of Federal Regulations, 2010 CFR
2010-01-01
... the instructions. (c) Protecting samples and data. Official personnel and other employees of an agency or the Service shall protect official weight samples and data from manipulation, substitution, and improper and careless handling which might deprive the samples and sample data of their representativeness...
7 CFR 800.99 - Checkweighing sacked grain.
Code of Federal Regulations, 2011 CFR
2011-01-01
... the instructions. (c) Protecting samples and data. Official personnel and other employees of an agency or the Service shall protect official weight samples and data from manipulation, substitution, and improper and careless handling which might deprive the samples and sample data of their representativeness...
Techniques for the analysis of data from coded-mask X-ray telescopes
NASA Technical Reports Server (NTRS)
Skinner, G. K.; Ponman, T. J.; Hammersley, A. P.; Eyles, C. J.
1987-01-01
Several techniques useful in the analysis of data from coded-mask telescopes are presented. Methods of handling changes in the instrument pointing direction are reviewed and ways of using FFT techniques to do the deconvolution considered. Emphasis is on techniques for optimally-coded systems, but it is shown that the range of systems included in this class can be extended through the new concept of 'partial cycle averaging'.
Automation of ⁹⁹Tc extraction by LOV prior ICP-MS detection: application to environmental samples.
Rodríguez, Rogelio; Leal, Luz; Miranda, Silvia; Ferrer, Laura; Avivar, Jessica; García, Ariel; Cerdà, Víctor
2015-02-01
A new, fast, automated and inexpensive sample pre-treatment method for (99)Tc determination by inductively coupled plasma-mass spectrometry (ICP-MS) detection is presented. The miniaturized approach is based on a lab-on-valve (LOV) system, allowing automatic separation and preconcentration of (99)Tc. Selectivity is provided by the solid phase extraction system used (TEVA resin) which retains selectively pertechnetate ion in diluted nitric acid solution. The proposed system has some advantages such as minimization of sample handling, reduction of reagents volume, improvement of intermediate precision and sample throughput, offering a significant decrease of both time and cost per analysis in comparison to other flow techniques and batch methods. The proposed LOV system has been successfully applied to different samples of environmental interest (water and soil) with satisfactory recoveries, between 94% and 98%. The detection limit (LOD) of the developed method is 0.005 ng. The high durability of the resin and its low amount (32 mg), its good intermediate precision (RSD 3.8%) and repeatability (RSD 2%) and its high extraction frequency (up to 5 h(-1)) makes this method an inexpensive, high precision and fast tool for monitoring (99)Tc in environmental samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Teachers' Questioning Techniques in Advanced Level Chemistry Lessons: A Tanzanian Perspective
ERIC Educational Resources Information Center
Kira, Ernest; Komba, Sotco; Kafanabo, Eugenia; Tilya, Frank
2013-01-01
This study investigated the extent to which teachers' questioning techniques and the way teachers handled students' responses facilitated students' learning and promoted their thinking skills. The study focused on three secondary schools in Dar es Salaam. The data collection process involved classroom observations during chemistry lessons and…
Collection & Processing of Vertebrate Specimens for Arbovirus Studies.
ERIC Educational Resources Information Center
Sudia, W. Daniel; And Others
Described are techniques used by the National Communicable Disease Center in obtaining blood and tissues from man and other vertebrates for arbovirus isolation and antibody studies. Also included are techniques for capturing and handling vertebrates; banding and marking; restraining and bleeding; storing of specimens to preserve antibody and…
ERIC Educational Resources Information Center
Stalans, Loretta J.; Finn, Mary A.
2006-01-01
The public's and police officers' interpretation and handling of realistic hypothetical domestic violence cases and their stereotypic views about domestic violence are discussed. A sample of 131 experienced officers, 127 novice officers, and 157 adult laypersons were randomly assigned to read a domestic violence case. Experienced officers were…
ERIC Educational Resources Information Center
Childress, Vincent W.
2007-01-01
The medical field has many uses for automated and remote-controlled technology. For example, if a tissue sample is only handled in the laboratory by a robotic handling system, then it will never come into contact with a human. Such a system not only helps to automate the medical testing process, but it also helps to reduce the chances of…
Psychosocial Determinants of Conflict-Handling Behaviour of Workers in Oil Sector in Nigeria
ERIC Educational Resources Information Center
Bankole, Akanji Rafiu
2011-01-01
The study examined the joint and relative influence of three psychosocial factors: Emotional intelligence, communication skill and interpersonal skill on conflict-handling behaviour of oil workers in Nigeria. Survey research design was adopted and a sample of 610 workers was randomly selected from oil companies across the country. Data were…
Hagenmaier, J A; Reinhardt, C D; Bartle, S J; Henningson, J N; Ritter, M J; Calvo-Lorenzo, M S; Vogel, G J; Guthrie, C A; Siemens, M G; Thomson, D U
2017-05-01
The effects of handling intensity on the physiological response and carcass characteristics of feedlot cattle fed ractopamine hydrochloride were evaluated at the time of transport to slaughter. Eighty steers (BW = 668 ± 36 kg) representing 10 lots of similar breed, frame size, and degree of finish were blocked by lot, stratified by weight, and randomly assigned to 1 of 2 handling intensities (HI) over a 1,600 m dirt alley course: 1) low-stress handling (LSH) or 2) high-stress handling (HSH). For the LSH treatment, 4 penmates were kept at a walk with the use of a lead rider. For the HSH treatment, 4 penmates were kept at a minimum of a trot and received 2 applications of an electric prod (approximately 1 s per impulse) at 2 separate instances: first in the alley before post-handling sampling, and again during loading for transportation to the abattoir. Behavioral observations and physical indicators of stress were recorded a minimum of 1 h before handling (baseline), immediately after handling (POSTHAND), and while in lairage after a 200 km transport to the abattoir. Vital parameters were recorded at baseline and POSTHAND. Venous blood samples were collected via jugular venipuncture at baseline and POSTHAND, and mixed arterial and venous blood samples were collected during exsanguination at slaughter. Muscle tremors tended to be more prevalent in HSH cattle at POSTHAND ( = 0.10). The HSH cattle tended to have greater POSTHAND heart rate ( = 0.08); however, there was no effect of HI on POSTHAND respiration rate or rectal temperature ( 0.34). The HSH cattle had greater lactate, epinephrine, norepinephrine, cortisol, and glucose concentrations at POSTHAND ( ≤ 0.02). Additionally, HSH cattle had lower POSTHAND blood pH, bicarbonate, base excess, and partial pressure carbon dioxide ( < 0.0001). Bicarbonate concentrations were greater in HSH cattle at slaughter ( = 0.05); however, there were no differences between HI treatments for the remaining blood variables ( 0.11). Concentrations of stress hormones and CK were significantly greater at slaughter relative to baseline and POSTHAND for both LSH and HSH cattle ( < 0.001). These findings suggest cattle trotted without a lead rider develop metabolic acidosis, and illustrate the importance of low-stress handling at the time of transport for slaughter. Further research is warranted to develop strategies to mitigate stress at the time of transport and ensure the welfare of beef cattle presented to abattoirs.
Small Particulate Contamination Survey Of Genesis Flight Sample 61423
NASA Technical Reports Server (NTRS)
Kuhlman, K. R.; Schmeling, M.; Gonzalez, C. P.; Allums, K. K.; Allton, J. H.; Burnett, D. S.
2016-01-01
The Genesis mission collected solar wind and brought it back to Earth in order to provide precise knowledge of solar isotopic and elemental compositions. The ions in the solar wind stop in the collectors at depths on the order of 10 to a few hundred nanometers. This shallow implantation layer is critical for scientific analysis of the composition of the solar wind and must be preserved throughout sample handling, cleaning, processing, distribution, preparation and analysis. We continue to work with the community of scientists analyzing Genesis samples using our unique laboratory facilities -- and, where needed, our unique cleaning techniques -- to significantly enhance the science return from the Genesis mission. This work is motivated by the need to understand the submicron contamination on the collectors in the Genesis payload as recovered from the crash site in the Utah desert, and -- perhaps more importantly -- how to remove it. We continue to evaluate the effectiveness of the wet-chemical "cleaning" steps used by various investigators, to enable them to design improved methods of stripping spacecraft and terrestrial contamination from surfaces while still leaving the solar-wind signal intact.
Treatment of kitchen wastewater using Eichhornia crassipes
NASA Astrophysics Data System (ADS)
Parwin, Rijwana; Karar Paul, Kakoli
2018-03-01
The efficiency of Eichhornia crassipes for treatment of raw kitchen wastewater was studied in the present research work. An artificial wetland of 30 liter capacity was created for phytoremediation of kitchen wastewater using Eichhornia crassipes. Kitchen wastewater samples were collected from hostel of an educational institute in India. Samples were characterized based on physical and chemical parameters such as pH, turbidity, total hardness, nitrate-nitrogen, ammonium-nitrogen, sulphate, dissolved oxygen, total organic carbon and total dissolved solid. The physico-chemical parameter of kitchen wastewater samples were analysed for durations of 0 (initial day), 4 and 8 days. After 8 days of retention period, it was observed that pH value increases from 6.25 to 6.63. However, percentage reduction for turbidity, total hardness, nitrate-nitrogen, ammonium-nitrogen, sulphate, dissolved oxygen, total organic carbon and total dissolved solid were found to be 74.71%, 50%, 78.75%, 60.28%, 25.31%, 33.33%, 15.38% and 69.97%, respectively. Hence water hyacinth (Eichhornia crassipes) is found efficient and easy to handle and it can be used for low cost phytoremediation technique.
Electronic nicotine delivery systems: regulatory and safety challenges: Singapore perspective.
Cheah, Nuan Ping; Chong, Norman Wee Lin; Tan, Jing; Morsed, Faridatul Akmam; Yee, Shen Kuan
2014-03-01
Many electronic nicotine delivery systems (ENDS) are marketed as safer tobacco alternative products or effective cessation therapies. ENDS samples were evaluated for design features, including nicotine and glycols content. This could be useful in developing a legal framework to handle ENDS. Identification of the nicotine, glycerol and propylene glycol (PPG) contents was conducted using gas chromatography mass spectrometry with quantification performed using flame ionisation techniques. Varying nicotine amounts were found in ENDS cartridges which were labelled with the same concentration. Chemicals such as PPG and glycerol were found to be present in the nicotine-containing liquid of the cartridges. ENDS varied in their contents and packaging information. Limited information was available on the contents of nicotine and other chemicals present in a variety of ENDS sampled. Based on samples tested in this study, many contain misleading information on product ingredients. The results show poor consistency between actual nicotine content analysed on ENDS cartridges and the amount labelled. These findings raise safety and efficacy concerns for current and would-be recreational users or those trying to quit smoking.
Rezk, Amgad R; Ramesan, Shwathy; Yeo, Leslie Y
2018-01-30
The microarray titre plate remains a fundamental workhorse in genomic, proteomic and cellomic analyses that underpin the drug discovery process. Nevertheless, liquid handling technologies for sample dispensing, processing and transfer have not progressed significantly beyond conventional robotic micropipetting techniques, which are not only at their fundamental sample size limit, but are also prone to mechanical failure and contamination. This is because alternative technologies to date suffer from a number of constraints, mainly their limitation to carry out only a single liquid operation such as dispensing or mixing at a given time, and their inability to address individual wells, particularly at high throughput. Here, we demonstrate the possibility for true sequential or simultaneous single- and multi-well addressability in a 96-well plate using a reconfigurable modular platform from which MHz-order hybrid surface and bulk acoustic waves can be coupled to drive a variety of microfluidic modes including mixing, sample preconcentration and droplet jetting/ejection in individual or multiple wells on demand, thus constituting a highly versatile yet simple setup capable of improving the functionality of existing laboratory protocols and processes.
The U.S. Geological Survey's TRIGA® reactor
DeBey, Timothy M.; Roy, Brycen R.; Brady, Sally R.
2012-01-01
The U.S. Geological Survey (USGS) operates a low-enriched uranium-fueled, pool-type reactor located at the Federal Center in Denver, Colorado. The mission of the Geological Survey TRIGA® Reactor (GSTR) is to support USGS science by providing information on geologic, plant, and animal specimens to advance methods and techniques unique to nuclear reactors. The reactor facility is supported by programs across the USGS and is organizationally under the Associate Director for Energy and Minerals, and Environmental Health. The GSTR is the only facility in the United States capable of performing automated delayed neutron analyses for detecting fissile and fissionable isotopes. Samples from around the world are submitted to the USGS for analysis using the reactor facility. Qualitative and quantitative elemental analyses, spatial elemental analyses, and geochronology are performed. Few research reactor facilities in the United States are equipped to handle the large number of samples processed at the GSTR. Historically, more than 450,000 sample irradiations have been performed at the USGS facility. Providing impartial scientific information to resource managers, planners, and other interested parties throughout the world is an integral part of the research effort of the USGS.
A core handling device for the Mars Sample Return Mission
NASA Technical Reports Server (NTRS)
Gwynne, Owen
1989-01-01
A core handling device for use on Mars is being designed. To provide a context for the design study, it was assumed that a Mars Rover/Sample Return (MRSR) Mission would have the following characteristics: a year or more in length; visits by the rover to 50 or more sites; 100 or more meter-long cores being drilled by the rover; and the capability of returning about 5 kg of Mars regolith to Earth. These characteristics lead to the belief that in order to bring back a variegated set of samples that can address the range of scientific objetives for a MRSR mission to Mars there needs to be considerable analysis done on board the rover. Furthermore, the discrepancy between the amount of sample gathered and the amount to be returned suggests that there needs to be some method of choosing the optimal set of samples. This type of analysis will require pristine material-unaltered by the drilling process. Since the core drill thermally and mechanically alters the outer diameter (about 10 pct) of the core sample, this outer area cannot be used. The primary function of the core handling device is to extract subsamples from the core and to position these subsamples, and the core itself if needed, with respect to the various analytical instruments that can be used to perform these analyses.
Dynamic stability and handling qualities tests on a highly augmented, statically unstable airplane
NASA Technical Reports Server (NTRS)
Gera, Joseph; Bosworth, John T.
1987-01-01
Initial envelope clearance and subsequent flight testing of a new, fully augmented airplane with an extremely high degree of static instability can place unusual demands on the flight test approach. Previous flight test experience with these kinds of airplanes is very limited or nonexistent. The safe and efficient flight testing may be further complicated by a multiplicity of control effectors that may be present on this class of airplanes. This paper describes some novel flight test and analysis techniques in the flight dynamics and handling qualities area. These techniques were utilized during the initial flight envelope clearance of the X-29A aircraft and were largely responsible for the completion of the flight controls clearance program without any incidents or significant delays.
Ferrari, M D; Neirotti, E; Albornoz, C
1998-01-01
Clean, dry and contaminant-free fuel is necessary for safe and economical aircraft operation. Microbial growth in aviation fuel handling systems can alter the quality of the product. This paper reports the occurrence of heterotrophic bacteria and fungi in a handling system of jet A-1 aviation turbine fuel. A total of 350 samples were collected during 1990-1996. The aerobic microorganisms in fuel samples were mainly fungi, 85% of samples containing < or = 100 cfu/l (range 0 (< 1 cfu/l) to 2000 cfu/l). The predominant fungi were Cladosporium and Aspergillus. Water was observed mainly in samples extracted from the drainage pipes of two tanks used frequently as intermediate storage tanks. The aerobic heterotrophic microorganisms found in water samples were mostly bacteria, counts varying from 100 to 8.8 x 10(7) cfu/ml, with 85% of samples containing 10(4)-10(7) cfu/ml. There was a preponderance of Pseudomonas spp. Bacterial contaminants belonging to the genus Flavobacterium and Aeromonas were also identified. Sulphate reducing bacteria were detected in 80% of water samples. It was not possible to assign a maximum microbial contamination level above which maintenance is required and it is suggested that analysis of successive samples from the same site are necessary for this purpose. Microbial sludges produced in the laboratory and collected from a contaminated tank bottom were analysed chemically. The data are presented and discussed. Samples collected from the supply pipes of tanks and refueller trucks during the period surveyed always met the standard specifications.
Space shuttle data handling and communications considerations.
NASA Technical Reports Server (NTRS)
Stoker, C. J.; Minor, R. G.
1971-01-01
Operational and development flight instrumentation, data handling subsystems and communication requirements of the space shuttle orbiter are discussed. Emphasis is made on data gathering methods, crew display data, computer processing, recording, and telemetry by means of a digital data bus. Also considered are overall communication conceptual system aspects and design features allowing a proper specification of telemetry encoders and instrumentation recorders. An adaptive bit rate concept is proposed to handle the telemetry bit rates which vary with the amount of operational and experimental data to be transmitted. A split-phase encoding technique is proposed for telemetry to cope with the excessive bit jitter and low bit transition density which may affect television performance.
NASA Astrophysics Data System (ADS)
Jandura, L.; Burke, K.; Kennedy, B.; Melko, J.; Okon, A.; Sunshine, D.
2009-12-01
The Sample Acquisition/Sample Processing and Handling (SA/SPaH) subsystem for the Mars Science Library (MSL) is a rover-based sampling system scheduled to launch in 2011. The SA/SPaH consists of a powdering drill and a scooping, sieving, and portioning device mounted on a turret at the end of a robotic arm. Also on the turret is a dust removal tool for clearing the surface of scientific targets, and two science instruments mounted on vibration isolators. The SA/SPaH can acquire powder from rocks at depths of 20 to 50 mm and can also pick up loose regolith with its scoop. The acquired sample is sieved and portioned and delivered to one of two instruments inside the rover for analysis. The functionality of the system will be described along with the targets the system can acquire and the sample that can be delivered. Top View of the SA/SPaH on the Rover
Adsorption losses from urine-based cannabinoid calibrators during routine use.
Blanc, J A; Manneh, V A; Ernst, R; Berger, D E; de Keczer, S A; Chase, C; Centofanti, J M; DeLizza, A J
1993-08-01
The major metabolite of cannabis found in urine, 11-nor-delta 9-tetrahydrocannabinol-9-carboxylic acid (delta 9-THC), is the compound most often used to calibrate cannabinoid immunoassays. The hydrophobic delta 9-THC molecule is known to adsorb to solid surfaces. This loss of analyte from calibrator solutions can lead to inaccuracy in the analytical system. Because the calibrators remain stable when not used, analyte loss is most probably caused by handling techniques. In an effort to develop an effective means of overcoming adsorption losses, we quantified cannabinoid loss from calibrators during the testing process. In studying handling of these solutions, we found noticeable, significant losses attributable to both the kind of pipette used for transfer and the contact surface-to-volume ratio of calibrator solution in the analyzer cup. Losses were quantified by immunoassay and by radioactive tracer. We suggest handling techniques that can minimize adsorption of delta 9-THC to surfaces. Using the appropriate pipette and maintaining a minimum surface-to-volume ratio in the analyzer cup effectively reduces analyte loss.
Welna, Maja; Szymczycha-Madeja, Anna
2014-04-01
Various sample preparation procedures, such as common wet digestions and alternatives based on solubilisation in aqua regia or tetramethyl ammonium hydroxide, were compared for the determination of the total Ba, Ca, Cr, Cd, Cu, Fe, Mg, Mn, Ni, P, Pb, Se, Sr and Zn contents in Brazil nuts using inductively coupled plasma optical emission spectrometry (ICP-OES). For measurement of Se, a hydride generation technique was used. The performance of these procedures was measured in terms of precision, accuracy and limits of detection of the elements. It was found that solubilisation in aqua regia gave the best results, i.e. limits of detection from 0.60 to 41.9 ng ml(-1), precision of 1.0-3.9% and accuracy better than 5%. External calibration with simple standard solutions could be applied for the analysis. The proposed procedure is simple, reduces sample handling, and minimises the time and reagent consumption. Thus, this can be a vital alternative to traditional sample treatment approaches based on the total digestion with concentrated reagents. A phenomenon resulting from levels of Ba, Se and Sr in Brazil nuts was also discussed.
NASA Astrophysics Data System (ADS)
Yamada, Yusuke; Hiraki, Masahiko; Sasajima, Kumiko; Matsugaki, Naohiro; Igarashi, Noriyuki; Amano, Yasushi; Warizaya, Masaichi; Sakashita, Hitoshi; Kikuchi, Takashi; Mori, Takeharu; Toyoshima, Akio; Kishimoto, Shunji; Wakatsuki, Soichi
2010-06-01
Recent advances in high-throughput techniques for macromolecular crystallography have highlighted the importance of structure-based drug design (SBDD), and the demand for synchrotron use by pharmaceutical researchers has increased. Thus, in collaboration with Astellas Pharma Inc., we have constructed a new high-throughput macromolecular crystallography beamline, AR-NE3A, which is dedicated to SBDD. At AR-NE3A, a photon flux up to three times higher than those at existing high-throughput beams at the Photon Factory, AR-NW12A and BL-5A, can be realized at the same sample positions. Installed in the experimental hutch are a high-precision diffractometer, fast-readout, high-gain CCD detector, and sample exchange robot capable of handling more than two hundred cryo-cooled samples stored in a Dewar. To facilitate high-throughput data collection required for pharmaceutical research, fully automated data collection and processing systems have been developed. Thus, sample exchange, centering, data collection, and data processing are automatically carried out based on the user's pre-defined schedule. Although Astellas Pharma Inc. has a priority access to AR-NE3A, the remaining beam time is allocated to general academic and other industrial users.
ISPyB: an information management system for synchrotron macromolecular crystallography.
Delagenière, Solange; Brenchereau, Patrice; Launer, Ludovic; Ashton, Alun W; Leal, Ricardo; Veyrier, Stéphanie; Gabadinho, José; Gordon, Elspeth J; Jones, Samuel D; Levik, Karl Erik; McSweeney, Seán M; Monaco, Stéphanie; Nanao, Max; Spruce, Darren; Svensson, Olof; Walsh, Martin A; Leonard, Gordon A
2011-11-15
Individual research groups now analyze thousands of samples per year at synchrotron macromolecular crystallography (MX) resources. The efficient management of experimental data is thus essential if the best possible experiments are to be performed and the best possible data used in downstream processes in structure determination pipelines. Information System for Protein crystallography Beamlines (ISPyB), a Laboratory Information Management System (LIMS) with an underlying data model allowing for the integration of analyses down-stream of the data collection experiment was developed to facilitate such data management. ISPyB is now a multisite, generic LIMS for synchrotron-based MX experiments. Its initial functionality has been enhanced to include improved sample tracking and reporting of experimental protocols, the direct ranking of the diffraction characteristics of individual samples and the archiving of raw data and results from ancillary experiments and post-experiment data processing protocols. This latter feature paves the way for ISPyB to play a central role in future macromolecular structure solution pipelines and validates the application of the approach used in ISPyB to other experimental techniques, such as biological solution Small Angle X-ray Scattering and spectroscopy, which have similar sample tracking and data handling requirements.
PIMS sequencing extension: a laboratory information management system for DNA sequencing facilities
2011-01-01
Background Facilities that provide a service for DNA sequencing typically support large numbers of users and experiment types. The cost of services is often reduced by the use of liquid handling robots but the efficiency of such facilities is hampered because the software for such robots does not usually integrate well with the systems that run the sequencing machines. Accordingly, there is a need for software systems capable of integrating different robotic systems and managing sample information for DNA sequencing services. In this paper, we describe an extension to the Protein Information Management System (PIMS) that is designed for DNA sequencing facilities. The new version of PIMS has a user-friendly web interface and integrates all aspects of the sequencing process, including sample submission, handling and tracking, together with capture and management of the data. Results The PIMS sequencing extension has been in production since July 2009 at the University of Leeds DNA Sequencing Facility. It has completely replaced manual data handling and simplified the tasks of data management and user communication. Samples from 45 groups have been processed with an average throughput of 10000 samples per month. The current version of the PIMS sequencing extension works with Applied Biosystems 3130XL 96-well plate sequencer and MWG 4204 or Aviso Theonyx liquid handling robots, but is readily adaptable for use with other combinations of robots. Conclusions PIMS has been extended to provide a user-friendly and integrated data management solution for DNA sequencing facilities that is accessed through a normal web browser and allows simultaneous access by multiple users as well as facility managers. The system integrates sequencing and liquid handling robots, manages the data flow, and provides remote access to the sequencing results. The software is freely available, for academic users, from http://www.pims-lims.org/. PMID:21385349
Stress-free automatic sleep deprivation using air puffs
Gross, Brooks A.; Vanderheyden, William M.; Urpa, Lea M.; Davis, Devon E.; Fitzpatrick, Christopher J.; Prabhu, Kaustubh; Poe, Gina R.
2015-01-01
Background Sleep deprivation via gentle handling is time-consuming and personnel-intensive. New Method We present here an automated sleep deprivation system via air puffs. Implanted EMG and EEG electrodes were used to assess sleep/waking states in six male Sprague-Dawley rats. Blood samples were collected from an implanted intravenous catheter every 4 hours during the 12-hour light cycle on baseline, 8 hours of sleep deprivation via air puffs, and 8 hours of sleep deprivation by gentle handling days. Results The automated system was capable of scoring sleep and waking states as accurately as our offline version (~90% for sleep) and with sufficient speed to trigger a feedback response within an acceptable amount of time (1.76 s). Manual state scoring confirmed normal sleep on the baseline day and sleep deprivation on the two manipulation days (68% decrease in non-REM, 63% decrease in REM, and 74% increase in waking). No significant differences in levels of ACTH and corticosterone (stress hormones indicative of HPA axis activity) were found at any time point between baseline sleep and sleep deprivation via air puffs. Comparison with Existing Method There were no significant differences in ACTH or corticosterone concentrations between sleep deprivation by air puffs and gentle handling over the 8-hour period. Conclusions Our system accurately detects sleep and delivers air puffs to acutely deprive rats of sleep with sufficient temporal resolution during the critical 4-5 h post learning sleep-dependent memory consolidation period. The system is stress-free and a viable alternative to existing sleep deprivation techniques. PMID:26014662
Stress-free automatic sleep deprivation using air puffs.
Gross, Brooks A; Vanderheyden, William M; Urpa, Lea M; Davis, Devon E; Fitzpatrick, Christopher J; Prabhu, Kaustubh; Poe, Gina R
2015-08-15
Sleep deprivation via gentle handling is time-consuming and personnel-intensive. We present here an automated sleep deprivation system via air puffs. Implanted EMG and EEG electrodes were used to assess sleep/waking states in six male Sprague-Dawley rats. Blood samples were collected from an implanted intravenous catheter every 4h during the 12-h light cycle on baseline, 8h of sleep deprivation via air puffs, and 8h of sleep deprivation by gentle handling days. The automated system was capable of scoring sleep and waking states as accurately as our offline version (∼90% for sleep) and with sufficient speed to trigger a feedback response within an acceptable amount of time (1.76s). Manual state scoring confirmed normal sleep on the baseline day and sleep deprivation on the two manipulation days (68% decrease in non-REM, 63% decrease in REM, and 74% increase in waking). No significant differences in levels of ACTH and corticosterone (stress hormones indicative of HPA axis activity) were found at any time point between baseline sleep and sleep deprivation via air puffs. There were no significant differences in ACTH or corticosterone concentrations between sleep deprivation by air puffs and gentle handling over the 8-h period. Our system accurately detects sleep and delivers air puffs to acutely deprive rats of sleep with sufficient temporal resolution during the critical 4-5h post learning sleep-dependent memory consolidation period. The system is stress-free and a viable alternative to existing sleep deprivation techniques. Copyright © 2015 Elsevier B.V. All rights reserved.
Kanai, Yae; Nishihara, Hiroshi; Miyagi, Yohei; Tsuruyama, Tatsuhiro; Taguchi, Kenichi; Katoh, Hiroto; Takeuchi, Tomoyo; Gotoh, Masahiro; Kuramoto, Junko; Arai, Eri; Ojima, Hidenori; Shibuya, Ayako; Yoshida, Teruhiko; Akahane, Toshiaki; Kasajima, Rika; Morita, Kei-Ichi; Inazawa, Johji; Sasaki, Takeshi; Fukayama, Masashi; Oda, Yoshinao
2018-02-01
Genome research using appropriately collected pathological tissue samples is expected to yield breakthroughs in the development of biomarkers and identification of therapeutic targets for diseases such as cancers. In this connection, the Japanese Society of Pathology (JSP) has developed "The JSP Guidelines on the Handling of Pathological Tissue Samples for Genomic Research" based on an abundance of data from empirical analyses of tissue samples collected and stored under various conditions. Tissue samples should be collected from appropriate sites within surgically resected specimens, without disturbing the features on which pathological diagnosis is based, while avoiding bleeding or necrotic foci. They should be collected as soon as possible after resection: at the latest within about 3 h of storage at 4°C. Preferably, snap-frozen samples should be stored in liquid nitrogen (about -180°C) until use. When intending to use genomic DNA extracted from formalin-fixed paraffin-embedded tissue, 10% neutral buffered formalin should be used. Insufficient fixation and overfixation must both be avoided. We hope that pathologists, clinicians, clinical laboratory technicians and biobank operators will come to master the handling of pathological tissue samples based on the standard operating procedures in these Guidelines to yield results that will assist in the realization of genomic medicine. © 2018 The Authors. Pathology International published by Japanese Society of Pathology and John Wiley & Sons Australia, Ltd.
Cohall, D H; Scantlebury-Manning, T; Rafie, C; James, S; Hall, K
2014-01-01
Recent nutritional profiles of dietary intake have indicated a shift from the ancient diet to the Western diet. The ancient diet provided a high potassium and low sodium intake, which in turn leads to sodium conservation and potassium excretion. This change in the dietary intake is expected to affect potassium and sodium handling in the kidneys. Numerous studies have been done to emphasize the importance of sodium handling by the kidneys and its impact on cardiovascular health. This study will investigate potassium intake and handling, and its impact on the cardiovascular health of a sample of normotensive Afro-Caribbeans by the possible modulation of the renin angiotensin aldosterone system (RAAS). A sample of 51 normotensive Afro-Caribbean participants was recruited for the study. Participants were observed over a two-day period in which they were given a 24-hour ambulatory blood pressure monitor and a container to collect blood pressure data and a 24-hour urine sample. Anthropometric measurements were noted. Urinary electrolytes and supine plasma renin activity (PRA) were determined from the 24-hour urine collection and a blood sample. Dietary potassium intake was estimated based on dietary intake observations and calculated based on the urinary potassium excretion. SPSS version 19 was used to analyse the data to make inferences. The daily potassium intake was observed to be 2.95 g/day and measured intake from the urinary potassium was between 4.95 and 7.32 g/day. Urinary potassium excretion was 3.66 (± 1.40) g/day. The urinary potassium excretion in the Afro-Caribbean sample in Barbados was higher than the other population samples. The averaged PRA of the participants (supine) was 0.778 (± 1.072) ng/mL/hour. The averaged nocturnal systolic blood pressure dip of the participants was 5.97 (± 4.324) %. There was no significant correlation between urinary potassium excretion, blood pressure, nocturnal systolic blood pressure dip and PRA. The Afro-Caribbean sample has an inadequate daily potassium intake based on the observed intake and recommended values, with a high urinary excretion of the electrolyte compared to other values in the literature. This high potassium excretion could have been partly due to low plasma renin activity levels in the study participants. As a possible consequence, an increase in the nocturnal peripheral resistance is a likely cause for the diminished systolic dip. The lack of correlations between dietary potassium excretion and the blood pressure parameters does not allow any firm inference of the electrolyte's handling and its impact on cardiovascular health in the normotensive Afro-Caribbean participants. However, further research is needed to get a more accurate daily potassium intake value, and a more statistically robust sample to assess whether potassium handling and blood pressure would be affected by a change in potassium intake.
Data handling and analysis for the 1971 corn blight watch experiment.
NASA Technical Reports Server (NTRS)
Anuta, P. E.; Phillips, T. L.; Landgrebe, D. A.
1972-01-01
Review of the data handling and analysis methods used in the near-operational test of remote sensing systems provided by the 1971 corn blight watch experiment. The general data analysis techniques and, particularly, the statistical multispectral pattern recognition methods for automatic computer analysis of aircraft scanner data are described. Some of the results obtained are examined, and the implications of the experiment for future data communication requirements of earth resource survey systems are discussed.
Cristiglio, Viviana; Grillo, Isabelle; Fomina, Margarita; Wien, Frank; Shalaev, Evgenyi; Novikov, Alexey; Brassamin, Séverine; Réfrégiers, Matthieu; Pérez, Javier; Hennet, Louis
2017-01-01
The acoustic levitation technique is a useful sample handling method for small solid and liquids samples, suspended in air by means of an ultrasonic field. This method was previously used at synchrotron sources for studying pharmaceutical liquids and protein solutions using x-ray diffraction and small angle x-ray scattering (SAXS). In this work we combined for the first time this containerless method with small angle neutron scattering (SANS) and synchrotron radiation circular dichroism (SRCD) to study the structural behavior of proteins in solutions during the water evaporation. SANS results are also compared with SAXS experiments. The aggregation behavior of 45μl droplets of lysozyme protein diluted in water was followed during the continuous increase of the sample concentration by evaporating the solvent. The evaporation kinetics was followed at different drying stage by SANS and SAXS with a good data quality. In a prospective work using SRCD, we also studied the evolution of the secondary structure of the myoglobin protein in water solution in the same evaporation conditions. Acoustic levitation was applied for the first time with SANS and the high performances of the used neutron instruments made it possible to monitor fast container-less reactions in situ. A preliminary work using SRCD shows the potentiality of its combination with acoustic levitation for studying the evolution of the protein structure with time. This multi-techniques approach could give novel insights into crystallization and self-assembly phenomena of biological compound with promising potential applications in pharmaceutical, food and cosmetics industry. This article is part of a Special Issue entitled "Science for Life" Guest Editor: Dr. Austen Angell, Dr. Salvatore Magazù and Dr. Federica Migliardo. Copyright © 2016 Elsevier B.V. All rights reserved.
Kennedy, Gordon J; Afeworki, Mobae; Calabro, David C; Chase, Clarence E; Smiley, Randolph J
2004-06-01
Distinct hydrogen species are present in important inorganic solids such as zeolites, silicoaluminophosphates (SAPOs), mesoporous materials, amorphous silicas, and aluminas. These H species include hydrogens associated with acidic sites such as Al(OH)Si, non-framework aluminum sites, silanols, and surface functionalities. Direct and quantitative methodology to identify, measure, and monitor these hydrogen species are key to monitoring catalyst activity, optimizing synthesis conditions, tracking post-synthesis structural modifications, and in the preparation of novel catalytic materials. Many workers have developed several techniques to address these issues, including 1H MAS NMR (magic-angle spinning nuclear magnetic resonance). 1H MAS NMR offers many potential advantages over other techniques, but care is needed in recognizing experimental limitations and developing sample handling and NMR methodology to obtain quantitatively reliable data. A simplified approach is described that permits vacuum dehydration of multiple samples simultaneously and directly in the MAS rotor without the need for epoxy, flame sealing, or extensive glovebox use. We have found that careful optimization of important NMR conditions, such as magnetic field homogeneity and magic angle setting are necessary to acquire quantitative, high-resolution spectra that accurately measure the concentrations of the different hydrogen species present. Details of this 1H MAS NMR methodology with representative applications to zeolites, SAPOs, M41S, and silicas as a function of synthesis conditions and post-synthesis treatments (i.e., steaming, thermal dehydroxylation, and functionalization) are presented.
NASA Technical Reports Server (NTRS)
Biezad, Daniel
1997-01-01
Handling qualities analysis and control law design would seem to be naturally complimenting components of aircraft flight control system design, however these two closely coupled disciplines are often not well integrated in practice. Handling qualities engineers and control system engineers may work in separate groups within an aircraft company. Flight control system engineers and handling quality specialists may come from different backgrounds and schooling and are often not aware of the other group's research. Thus while the handling qualities specifications represent desired aircraft response characteristics, these are rarely incorporated directly in the control system design process. Instead modem control system design techniques are based on servo-loop robustness specifications, and simple representations of the desired control response. Comprehensive handling qualities analysis is often left until the end of the design cycle and performed as a check of the completed design for satisfactory performance. This can lead to costly redesign or less than satisfactory aircraft handling qualities when the flight testing phase is reached. The desire to integrate the fields of handling qualities and flight,control systems led to the development of the CONDUIT system. This tool facilitates control system designs that achieve desired handling quality requirements and servo-loop specifications in a single design process. With CONDUIT, the control system engineer is now able to directly design and control systems to meet the complete handling specifications. CONDUIT allows the designer to retain a preferred control law structure, but then tunes the system parameters to meet the handling quality requirements.
Analytical study of comet nucleus samples
NASA Technical Reports Server (NTRS)
Albee, A. L.
1989-01-01
Analytical procedures for studying and handling frozen (130 K) core samples of comet nuclei are discussed. These methods include neutron activation analysis, x ray fluorescent analysis and high resolution mass spectroscopy.
Breath alcohol, multisensor arrays, and electronic noses
NASA Astrophysics Data System (ADS)
Paulsson, Nils; Winquist, Fredrik
1997-01-01
The concept behind a volatile compound mapper, or electronic nose, is to use the combination of multiple gas sensors and pattern recognition techniques to detect and quantify substances in gas mixtures. There are several different kinds of sensors which have been developed during recent years of which the base techniques are conducting polymers, piezo electrical crystals and solid state devices. In this work we have used a combination of gas sensitive field effect devices and semiconducting metal oxides. The most useful pattern recognition routine was found to be ANNs, which is a mathematical approximation of the human neural network. The aim of this work is to evaluate the possibility of using electronic noses in field instruments to detect drugs, arson residues, explosives etc. As a test application we have chosen breath alcohol measurements. There are several reasons for this. Breath samples are a quite complex mixture contains between 200 and 300 substances at trace levels. The alcohol level is low but still possible to handle. There are needs for replacing large and heavy mobile instruments with smaller devices. Current instrumentation is rather sensitive to interfering substances. The work so far has dealt with sampling, how to introduce ethanol and other substances in the breath, correlation measurements between the electronic nose and headspace GC, and how to evaluate the sensor signals.
Individual Information-Centered Approach for Handling Physical Activity Missing Data
ERIC Educational Resources Information Center
Kang, Minsoo; Rowe, David A.; Barreira, Tiago V.; Robinson, Terrance S.; Mahar, Matthew T.
2009-01-01
The purpose of this study was to validate individual information (II)-centered methods for handling missing data, using data samples of 118 middle-aged adults and 91 older adults equipped with Yamax SW-200 pedometers and Actigraph accelerometers for 7 days. We used a semisimulation approach to create six data sets: three physical activity outcome…
The Impact of Different Missing Data Handling Methods on DINA Model
ERIC Educational Resources Information Center
Sünbül, Seçil Ömür
2018-01-01
In this study, it was aimed to investigate the impact of different missing data handling methods on DINA model parameter estimation and classification accuracy. In the study, simulated data were used and the data were generated by manipulating the number of items and sample size. In the generated data, two different missing data mechanisms…
Handling Missing Data in Educational Research Using SPSS
ERIC Educational Resources Information Center
Cheema, Jehanzeb
2012-01-01
This study looked at the effect of a number of factors such as the choice of analytical method, the handling method for missing data, sample size, and proportion of missing data, in order to evaluate the effect of missing data treatment on accuracy of estimation. In order to accomplish this a methodological approach involving simulated data was…
40 CFR Appendix I to Part 264 - Recordkeeping Instructions
Code of Federal Regulations, 2010 CFR
2010-07-01
...., liquid, sludge, solid, or contained gas. If the waste is not listed in part 261, subpart D, of this... from production of ----, EPA Hazardous Waste Number W051). Each hazardous waste listed in part 261... Methods Enter the handling code(s) listed below that most closely represents the technique(s) used at the...
ERIC Educational Resources Information Center
Davis, Craig M.; Curran, Kelly A.
2007-01-01
Before taking an inorganic laboratory course few students have experience handling air-sensitive materials using Schlenk techniques. This exercise introduces them to techniques they will employ in later syntheses. The procedure involves the formation of anhydrous tetrahydrofuran complexes of transition-metal chlorides from metal-chloride hydrates;…
Pantomime Production by People with Aphasia: What Are Influencing Factors?
ERIC Educational Resources Information Center
van Nispen, Karin; van de Sandt-Koenderman, Mieke; Mol, Lisette; Krahmer, Emiel
2016-01-01
Purpose: The present article aimed to inform clinical practice on whether people with aphasia (PWA) deploy pantomime techniques similarly to participants without brain damage (PWBD) and if not, what factors influence these differences. Method: We compared 38 PWA to 20 PWBD in their use of 6 representation techniques ("handling,"…
Handling nonnormality and variance heterogeneity for quantitative sublethal toxicity tests.
Ritz, Christian; Van der Vliet, Leana
2009-09-01
The advantages of using regression-based techniques to derive endpoints from environmental toxicity data are clear, and slowly, this superior analytical technique is gaining acceptance. As use of regression-based analysis becomes more widespread, some of the associated nuances and potential problems come into sharper focus. Looking at data sets that cover a broad spectrum of standard test species, we noticed that some model fits to data failed to meet two key assumptions-variance homogeneity and normality-that are necessary for correct statistical analysis via regression-based techniques. Failure to meet these assumptions often is caused by reduced variance at the concentrations showing severe adverse effects. Although commonly used with linear regression analysis, transformation of the response variable only is not appropriate when fitting data using nonlinear regression techniques. Through analysis of sample data sets, including Lemna minor, Eisenia andrei (terrestrial earthworm), and algae, we show that both the so-called Box-Cox transformation and use of the Poisson distribution can help to correct variance heterogeneity and nonnormality and so allow nonlinear regression analysis to be implemented. Both the Box-Cox transformation and the Poisson distribution can be readily implemented into existing protocols for statistical analysis. By correcting for nonnormality and variance heterogeneity, these two statistical tools can be used to encourage the transition to regression-based analysis and the depreciation of less-desirable and less-flexible analytical techniques, such as linear interpolation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tuomas, V.; Jaakko, L.
This article discusses the optimization of the target motion sampling (TMS) temperature treatment method, previously implemented in the Monte Carlo reactor physics code Serpent 2. The TMS method was introduced in [1] and first practical results were presented at the PHYSOR 2012 conference [2]. The method is a stochastic method for taking the effect of thermal motion into account on-the-fly in a Monte Carlo neutron transport calculation. It is based on sampling the target velocities at collision sites and then utilizing the 0 K cross sections at target-at-rest frame for reaction sampling. The fact that the total cross section becomesmore » a distributed quantity is handled using rejection sampling techniques. The original implementation of the TMS requires 2.0 times more CPU time in a PWR pin-cell case than a conventional Monte Carlo calculation relying on pre-broadened effective cross sections. In a HTGR case examined in this paper the overhead factor is as high as 3.6. By first changing from a multi-group to a continuous-energy implementation and then fine-tuning a parameter affecting the conservativity of the majorant cross section, it is possible to decrease the overhead factors to 1.4 and 2.3, respectively. Preliminary calculations are also made using a new and yet incomplete optimization method in which the temperature of the basis cross section is increased above 0 K. It seems that with the new approach it may be possible to decrease the factors even as low as 1.06 and 1.33, respectively, but its functionality has not yet been proven. Therefore, these performance measures should be considered preliminary. (authors)« less
Evaluation in industry of a draft code of practice for manual handling.
Ashby, Liz; Tappin, David; Bentley, Tim
2004-05-01
This paper reports findings from a study which evaluated the draft New Zealand Code of Practice for Manual Handling. The evaluation assessed the ease of use, applicability and validity of the Code and in particular the associated manual handling hazard assessment tools, within New Zealand industry. The Code was studied in a sample of eight companies from four sectors of industry. Subjective feedback and objective findings indicated that the Code was useful, applicable and informative. The manual handling hazard assessment tools incorporated in the Code could be adequately applied by most users, with risk assessment outcomes largely consistent with the findings of researchers using more specific ergonomics methodologies. However, some changes were recommended to the risk assessment tools to improve usability and validity. The evaluation concluded that both the Code and the tools within it would benefit from simplification, improved typography and layout, and industry-specific information on manual handling hazards.
Raman spectroscopic studies on bacteria
NASA Astrophysics Data System (ADS)
Maquelin, Kees; Choo-Smith, Lin-P'ing; Endtz, Hubert P.; Bruining, Hajo A.; Puppels, Gerwin J.
2000-11-01
Routine clinical microbiological identification of pathogenic micro-organisms is largely based on nutritional and biochemical tests. Laboratory results can be presented to a clinician after 2 - 3 days for most clinically relevant micro- organisms. Most of this time is required to obtain pure cultures and enough biomass for the tests to be performed. In the case of severely ill patients, this unavoidable time delay associated with such identification procedures can be fatal. A novel identification method based on confocal Raman microspectroscopy will be presented. With this method it is possible to obtain Raman spectra directly from microbial microcolonies on the solid culture medium, which have developed after only 6 hours of culturing for most commonly encountered organisms. Not only does this technique enable rapid (same day) identifications, but also preserves the sample allowing it to be double-checked with traditional tests. This, combined with the speed and minimal sample handling indicate that confocal Raman microspectroscopy has much potential as a powerful new tool in clinical diagnostic microbiology.
Self-arraying of charged levitating droplets.
Kauffmann, Paul; Nussbaumer, Jérémie; Masse, Alain; Jeandey, Christian; Grateau, Henri; Pham, Pascale; Reyne, Gilbert; Haguet, Vincent
2011-06-01
Diamagnetic levitation of water droplets in air is a promising phenomenon to achieve contactless manipulation of chemical or biochemical samples. This noncontact handling technique prevents contaminations of samples as well as provides measurements of interaction forces between levitating reactors. Under a nonuniform magnetic field, diamagnetic bodies such as water droplets experience a repulsive force which may lead to diamagnetic levitation of a single or few micro-objects. The levitation of several repulsively charged picoliter droplets was successfully performed in a ~1 mm(2) adjustable flat magnetic well provided by a centimeter-sized cylindrical permanent magnet structure. Each droplet position results from the balance between the centripetal diamagnetic force and the repulsive Coulombian forces. Levitating water droplets self-organize into satellite patterns or thin clouds, according to their charge and size. Small triangular lattices of identical droplets reproduce magneto-Wigner crystals. Repulsive forces and inner charges can be measured in the piconewton and the femtocoulomb ranges, respectively. Evolution of interaction forces is accurately followed up over time during droplet evaporation.
Bergh, Daniel
2015-01-01
Chi-square statistics are commonly used for tests of fit of measurement models. Chi-square is also sensitive to sample size, which is why several approaches to handle large samples in test of fit analysis have been developed. One strategy to handle the sample size problem may be to adjust the sample size in the analysis of fit. An alternative is to adopt a random sample approach. The purpose of this study was to analyze and to compare these two strategies using simulated data. Given an original sample size of 21,000, for reductions of sample sizes down to the order of 5,000 the adjusted sample size function works as good as the random sample approach. In contrast, when applying adjustments to sample sizes of lower order the adjustment function is less effective at approximating the chi-square value for an actual random sample of the relevant size. Hence, the fit is exaggerated and misfit under-estimated using the adjusted sample size function. Although there are big differences in chi-square values between the two approaches at lower sample sizes, the inferences based on the p-values may be the same.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alnajjar, Mikhail S.; Quigley, David; Kuntamukkula, Murty
Due to the inherent nature of pyrophoric substances to ignite spontaneously upon exposure to air, special precautions must be taken to ensure their safe handling and use. Pyrophoric gases (such as diborane, dichloroborane, phosphine, etc.) are typically the easiest class of pyrophoric substances to handle since the gas can be plumbed directly to the application and used remotely. Pyrophoric solids and liquids, however, require the user to physically manipulate them when transferring them from one container to another. Failure to follow proper safety precautions could result in serious injury or unintended consequences to laboratory personnel.12 Because of this danger, pyrophoricsmore » should be handled only by experienced personnel. Users with limited experience must be trained on how to handle pyrophoric reagents and consult with a knowledgeable staff member prior to performing the experimental task. The purpose of this article is three fold: 1) to provide guidelines and general safety precautions to avoid accidents, 2) describe proper techniques on how to successfully handle, store, and dispose of pyrophoric liquids and solids, and 3) illustrate best practices for working with this class of reactants in a laboratory environment.« less
NASA Astrophysics Data System (ADS)
Miller, C. J.; Yoder, T. S.
2010-06-01
Explosive trace detection equipment has been deployed to airports for more than a decade. During this time, the need for standardized procedures and calibrated trace amounts for ensuring that the systems are operating properly and detecting the correct explosive has been apparent but a standard representative of a fingerprint has been elusive. Standards are also necessary to evaluate instrumentation in the laboratories during development and prior to deployment to determine sample throughput, probability of detection, false positive/negative rates, ease of use by operator, mechanical and/or software problems that may be encountered, and other pertinent parameters that would result in the equipment being unusable during field operations. Since many laboratories do not have access to nor are allowed to handle explosives, the equipment is tested using techniques aimed at simulating the actual explosives fingerprint. This laboratory study focused on examining the similarities and differences in three different surface contamination techniques that are used to performance test explosive trace detection equipment in an attempt to determine how effective the techniques are at replicating actual field samples and to offer scenarios where each contamination technique is applicable. The three techniques used were dry transfer deposition of standard solutions using the Transportation Security Laboratory’s (TSL) patented dry transfer techniques (US patent 6470730), direct deposition of explosive standards onto substrates, and fingerprinting of actual explosives onto substrates. RDX was deposited on the surface of one of five substrates using one of the three different deposition techniques. The process was repeated for each substrate type using each contamination technique. The substrate types used were: 50% cotton/50% polyester as found in T-shirts, 100% cotton with a smooth surface such as that found in a cotton dress shirt, 100% cotton on a rough surface such as that found on canvas or denim, suede leather such as might be found on jackets, purses, or shoes, and painted metal obtained from a car hood at a junk yard. The samples were not pre-cleaned prior to testing and contained sizing agents, and in the case of the metal, oil and dirt. The substrates were photographed using a Zeiss Discover V12 stereoscope with Axiocam ICc1 3 megapixel digital camera to determine the difference in the crystalline structure and surface contamination in an attempt to determine differences and similarities associated with current contamination deposition techniques. Some samples were analyzed using scanning electron microscopy (SEM) and some were extracted and analyzed with high performance liquid chromatography (HPLC) or gas chromatography with an electron capture detector (GC-ECD) to quantify the data.
Activity Detection and Retrieval for Image and Video Data with Limited Training
2015-06-10
applications. Here we propose two techniques for image segmentation. The first involves an automata based multiple threshold selection scheme, where a... automata . For our second approach to segmentation, we employ a region based segmentation technique that is capable of handling intensity inhomogeneity...techniques for image segmentation. The first involves an automata based multiple threshold selection scheme, where a mixture of Gaussian is fitted to the
Free Radical Polymerization of Styrene: A Radiotracer Experiment
ERIC Educational Resources Information Center
Mazza, R. J.
1975-01-01
Describes an experiment designed to acquaint the chemistry student with polymerization reactions, vacuum techniques, liquid scintillation counting, gas-liquid chromatography, and the handling of radioactive materials. (MLH)
A new tritium monitor design based on plasma source ion implantation technique
NASA Astrophysics Data System (ADS)
Nassar, Rafat Mohammad
Tritium is an important isotope of hydrogen. The availability of tritium in our environment is manifest through both natural and artificial sources. Consequently, the requirement for tritium handling and usage will continue to increase in the future. An important future contributor is nuclear fusion power plants and facilities. Essential safety regulations and procedures require effective monitoring and measurements of tritium concentrations in workplaces. The unique characteristics of tritium impose an important role on the criteria for its detection and measurement. As tritium decays by the emission of soft beta particles, maximum 18 keV, it cannot be readily detected by commonly used detectors. Specially built monitors are required. Additional complications occur due to the presence of other radioactive isotopes or ambient radiation fields and because of the high diffusivity of tritium. When it is in oxidized form it is 25000 times more hazardous biologically than when in elemental form. Therefore, contamination of the monitor is expected and compound specific monitors are important. A summary is given of the various well known methods of detecting tritium-in-air. This covers the direct as well as the indirect measuring techniques, although each has been continually improved and further developed, nevertheless, each has its own limitations. Ionization chambers cannot discriminate against airborne P emitters. Proportional counters have a narrow operating range, 3-4 decades, and have poor performance in relatively high humid environments and require a dry counting gas. Liquid scintillation counters are sensitive, but inspection of the sample is slow and they produce chemical liquid waste. A new way to improve the sensitivity of detecting tritium with plastic scintillators has been developed. The technique is based on a non-line-of-sight implantation of tritium ions into a 20 mum plastic scintillator using a plasma source ion implantation (PSII) technique, This type of source is different, superior to the line-of-sight implantation and requires no additional beam handling. It is capable of implanting ion species in a broad beam configuration into the entire surface of a target. The technique requires a special ion source with special characteristics of the type obtained from a surfatron plasma source. This ion source has a large high ion density plasma with minimum contamination and produces ions of low temperature. It was constructed to ionize the sampled air and to produce a plasma over a wide range of pressure, 4-0.1 mTorr. A plasma source ion implantation cell was designed and constructed using mathematical modeling with personal computer, to optimize the essential variables of the design and to estimate the implantation rate under different operation conditions. Also, a high voltage pulse modulator was designed and constructed to produce a series of 10 musec pulses (up to 2 MHz) with a maximum magnitude of -60 kV. The developed device was capable of ionizing air samples and implanting the resulting ions into a plastic scintillator. Two different methods to enhance the collection and deposition of the tritium ions, have been proposed and assessed. A movable prototype device for monitoring environmental tritium in air has been designed and constructed. Although this prototype was not fully tested, the primary calculations have shown that measurable concentrations of tritium ions can be collected from an air sample, with tritium activity ranging from 0.3 Bq/cm3 down to 0.03 mBq/cm3, in a short time, to the order of seconds, on-line. This sensitivity fulfills the requirement for environmental monitoring.
USDA-ARS?s Scientific Manuscript database
Statistically robust sampling strategies form an integral component of grain storage and handling activities throughout the world. Developing sampling strategies to target biological pests such as insects in stored grain is inherently difficult due to species biology and behavioral characteristics. ...
X-Ray Computed Tomography: The First Step in Mars Sample Return Processing
NASA Technical Reports Server (NTRS)
Welzenbach, L. C.; Fries, M. D.; Grady, M. M.; Greenwood, R. C.; McCubbin, F. M.; Zeigler, R. A.; Smith, C. L.; Steele, A.
2017-01-01
The Mars 2020 rover mission will collect and cache samples from the martian surface for possible retrieval and subsequent return to Earth. If the samples are returned, that mission would likely present an opportunity to analyze returned Mars samples within a geologic context on Mars. In addition, it may provide definitive information about the existence of past or present life on Mars. Mars sample return presents unique challenges for the collection, containment, transport, curation and processing of samples [1] Foremost in the processing of returned samples are the closely paired considerations of life detection and Planetary Protection. In order to achieve Mars Sample Return (MSR) science goals, reliable analyses will depend on overcoming some challenging signal/noise-related issues where sparse martian organic compounds must be reliably analyzed against the contamination background. While reliable analyses will depend on initial clean acquisition and robust documentation of all aspects of developing and managing the cache [2], there needs to be a reliable sample handling and analysis procedure that accounts for a variety of materials which may or may not contain evidence of past or present martian life. A recent report [3] suggests that a defined set of measurements should be made to effectively inform both science and Planetary Protection, when applied in the context of the two competing null hypotheses: 1) that there is no detectable life in the samples; or 2) that there is martian life in the samples. The defined measurements would include a phased approach that would be accepted by the community to preserve the bulk of the material, but provide unambiguous science data that can be used and interpreted by various disciplines. Fore-most is the concern that the initial steps would ensure the pristine nature of the samples. Preliminary, non-invasive techniques such as computed X-ray tomography (XCT) have been suggested as the first method to interrogate and characterize the cached samples without altering the materials [1,2]. A recent report [4] indicates that XCT may minimally alter samples for some techniques, and work is needed to quantify these effects, maximizing science return from XCT initial analysis while minimizing effects.
EVA Swab Tool to Support Planetary Protection and Astrobiology Evaluations
NASA Technical Reports Server (NTRS)
Rucker, Michelle A.; Hood, Drew; Walker, Mary; Venkateswaran, Kasthuri J.; Schuerger, Andrew C.
2018-01-01
When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed systems meet planetary protection requirements-and to protect our science from human contamination-we'll need to assess whether microorganisms may be leaking or venting from our spacecraft. Microbial sample collection outside of a pressurized spacecraft is complicated by temperature extremes, low pressures that preclude the use of laboratory standard (wetted) swabs, and operation either in bulky spacesuits or with robotic assistance. Engineers at the National Aeronautics and Space Administration (NASA) recently developed a swab kit for use in collecting microbial samples from the external surfaces of crewed spacecraft, including spacesuits. The Extravehicular Activity (EVA) Swab Kit consists of a single swab tool handle and an eight-canister sample caddy. The design team minimized development cost by re-purposing a heritage Space Shuttle tile repair handle that was designed to quickly snap into different tool attachments by engaging a mating device in each attachment. This allowed the tool handle to snap onto a fresh swab attachment much like popular shaving razor handles can snap onto a disposable blade cartridge. To disengage the handle from a swab, the user performs two independent functions, which can be done with a single hand. This dual operation mitigates the risk that a swab will be inadvertently released and lost in microgravity. Each swab attachment is fitted with commercially available foam swab tips, vendor-certified to be sterile for Deoxyribonucleic Acid (DNA). A microbial filter installed in the bottom of each sample container allows the container to outgas and repressurize without introducing microbial contaminants to internal void spaces. Extensive ground testing, post-test handling, and sample analysis confirmed the design is able to maintain sterile conditions as the canister moves between various pressure environments. To further minimize cost, the design team acquired extensive ground test experience in a relevant flight environment by piggy-backing onto suited crew training runs. These training runs allowed the project to validate tool interfaces with pressurized EVA gloves and collect user feedback on the tool design and function, as well as characterize baseline microbial data for different types of spacesuits. In general, test subjects found the EVA Swab Kit relatively straightforward to operate, but identified a number of design improvements that will be incorporated into the final design. Although originally intended to help characterize human forward contaminants, this tool has other potential applications, such as for collecting and preserving space-exposed materials to support astrobiology experiments.
Implications for patient safety in the use of safe patient handling equipment: a national survey.
Elnitsky, Christine A; Lind, Jason D; Rugs, Deborah; Powell-Cope, Gail
2014-12-01
The prevalence of musculoskeletal injuries among nursing staff has been high due to patient handling and movement. Internationally, healthcare organizations are integrating technological equipment into patient handling and movement to improve safety. Although evidence shows that safe patient handling programs reduce work-related musculoskeletal injuries in nursing staff, it is not clear how safe these new programs are for patients. The objective of this study was to explore adverse patient events associated with safe patient handling programs and preventive approaches in US Veterans Affairs medical centers. The study surveyed a convenience sample of safe patient handling program managers from 51 US Department of Veterans Affairs medical centers to collect data on skin-related and fall-related adverse patient events. Both skin- and fall-related adverse patient events associated with safe patient handling occurred at VA Medical centers. Skin-related events included abrasions, contusions, pressure ulcers and lacerations. Fall-related events included sprains and strains, fractures, concussions and bleeding. Program managers described contextual factors in these adverse events and ways of preventing the events. The use of safe patient handling equipment can pose risks for patients. This study found that organizational factors, human factors and technology factors were associated with patient adverse events. The findings have implications for how nursing professionals can implement safe patient handling programs in ways that are safe for both staff and patients. Published by Elsevier Ltd.
Weinand, Christian; Peretti, Giuseppe M; Adams, Samuel B; Randolph, Mark A; Savvidis, Estafios; Gill, Thomas J
2006-11-01
Successful treatment of tears to the avascular region of the meniscus remains a challenge. Current repair techniques, such as sutures and anchors, are effective in stabilizing the peripheral, vascularized regions of the meniscus, but are not adequate for promoting healing in the avascular region. The purpose of this study was to demonstrate the healing ability of a tissue-engineered repair technique using allogenic chondrocytes from three different sources for the avascular zone of the meniscus. Articular, auricular, and costal chondrocytes were harvested from 3-month-old Yorkshire swine. A 1-cm bucket-handle lesion was created in the avascular zone of each three swine. A cell-scaffold construct, composed of a single chondrocyte cell type and Vicryl mesh, was implanted into the lesion and secured with two vertical mattress sutures. Controls consisted of each three sutured unseeded mesh implants, suture only, and untreated lesions. The swine were allowed immediate post-operative full weight bearing. Menisci and controls were harvested after 12 weeks. In all experimental samples, lesion closure was observed. Gross mechanical testing with two Adson forceps demonstrated bonding of the lesion. Histological analysis showed formation of new tissue in all three experimental samples. None of the control samples demonstrated closure and formation of new matrix. We present preliminary data that demonstrates the potential of a tissue-engineered, allogenic cellular repair to provide successful healing of lesions in the avascular zone in a large animal model.
Effects of handling intensity and live weight on blood acid-base status in finishing pigs.
Hamilton, D N; Ellis, M; Bertol, T M; Miller, K D
2004-08-01
The objective of this study was to determine the effect of live weight on the plasma acid-base response of pigs subjected to various handling intensities. Eighty pigs (equal numbers of barrows and gilts) were used in a completely randomized block design with a 2 x 2 x 2 factorial arrangement of the following treatments: 1) live weight (light [104 kg] vs. heavy [128 kg]), 2) handling intensity (low vs. high), and 3) gender (barrows vs. gilts). Before the handling test, pigs were weighed, venous blood samples were taken to establish baseline levels, and rectal temperature was measured. Pigs were allowed to rest for 2 h before being subjected to the handling treatments, which consisted of moving the pigs through a course (12.2 m long x 0.91 m wide), for a total of eight laps. Animals on the high-intensity treatment were moved rapidly through the course and subjected to a total of 16 single shocks (two shocks per lap) with an electric livestock goad, whereas pigs on the low-intensity treatment were moved at their own pace using a moving panel and a paddle. Rectal temperature and a venous blood sample were taken immediately after handling and at 2 h after handling. Blood plasma was assayed for pH, partial pressure of carbon dioxide (PCO2), partial pressure of oxygen (PO2), saturated oxygen (SO2), total carbon dioxide (TCO2), bicarbonate (HCO3), base excess, and lactate. Live weight had no effect on the baseline measurements. After handling, light pigs had higher (P < 0.05) blood SO2 (65.6 vs. 57.2+/-2.80%) and showed a greater (P < 0.05) increase in PO2 from baseline to post-handling than heavy pigs (15.6 vs. 8.3+/-2.63 mmHg). Post-handling, pigs on the high- compared with the low-intensity handling treatment had greater (P < 0.001) lactate (19.1 vs. 4.9+/-0.56 mmol/L) and PO2 (51.6 vs. 36.5+/-2.44 mmHg) with lower (P < 0.001) TCO2 (18.6 vs. 34.7+/-0.64 mmol/L), pH (7.02 vs. 7.36+/-0.015), HCO3 (16.7 vs. 33.0+/-0.62 mmol/L), and base excess (-14.2 vs. 7.5+/-0.75) values. There were no effects of gender on blood measurements or rectal temperatures. Results from this study highlight a major effect of pig handling intensity, a limited effect of live weight, and no effect of gender on blood acid-base responses to handling.
Toxic-Waste Disposal by Combustion in Containers
NASA Technical Reports Server (NTRS)
Houseman, J.; Stephens, J. B.; Moynihan, P. I.; Compton, L. E.; Kalvinskas, J. J.
1986-01-01
Chemical wastes burned with minimal handling in storage containers. Technique for disposing of chemical munitions by burning them inside shells applies to disposal of toxic materials stored in drums. Fast, economical procedure overcomes heat-transfer limitations of conventional furnace designs by providing direct contact of oxygenrich combustion gases with toxic agent. No need to handle waste material, and container also decontaminated in process. Oxygen-rich torch flame cuts burster well and causes vaporization and combustion of toxic agent contained in shell.
Historical overview of V/STOL aircraft technology
NASA Technical Reports Server (NTRS)
Anderson, S. B.
1981-01-01
The requirements for satisfactory characteristics in several key technology areas are discussed and a review is made of various V/STOL aircraft for the purpose of assessing the success or failure of each design in meeting design requirements. Special operating techniques were developed to help circumvent deficiencies. For the most part performance and handling qualities limitations restricted operational evaluations. Flight operations emphasized the need for good STOL performance, good handling qualities, and stability and control augmentation. The majority of aircraft suffered adverse ground effects.
NASA Technical Reports Server (NTRS)
Platt, M. E.; Lewis, E. E.; Boehm, F.
1991-01-01
A Monte Carlo Fortran computer program was developed that uses two variance reduction techniques for computing system reliability applicable to solving very large highly reliable fault-tolerant systems. The program is consistent with the hybrid automated reliability predictor (HARP) code which employs behavioral decomposition and complex fault-error handling models. This new capability is called MC-HARP which efficiently solves reliability models with non-constant failures rates (Weibull). Common mode failure modeling is also a specialty.
Some queuing network models of computer systems
NASA Technical Reports Server (NTRS)
Herndon, E. S.
1980-01-01
Queuing network models of a computer system operating with a single workload type are presented. Program algorithms are adapted for use on the Texas Instruments SR-52 programmable calculator. By slightly altering the algorithm to process the G and H matrices row by row instead of column by column, six devices and an unlimited job/terminal population could be handled on the SR-52. Techniques are also introduced for handling a simple load dependent server and for studying interactive systems with fixed multiprogramming limits.
ERIC Educational Resources Information Center
Ellis, Tom
2000-01-01
Examines tested techniques that can keep a school's carpeting in good condition. Cleaning with hot water extraction, removing spills and spots, handling emergency cleanups, and cleaning soft surface flooring are addressed. (GR)
Processing techniques for software based SAR processors
NASA Technical Reports Server (NTRS)
Leung, K.; Wu, C.
1983-01-01
Software SAR processing techniques defined to treat Shuttle Imaging Radar-B (SIR-B) data are reviewed. The algorithms are devised for the data processing procedure selection, SAR correlation function implementation, multiple array processors utilization, cornerturning, variable reference length azimuth processing, and range migration handling. The Interim Digital Processor (IDP) originally implemented for handling Seasat SAR data has been adapted for the SIR-B, and offers a resolution of 100 km using a processing procedure based on the Fast Fourier Transformation fast correlation approach. Peculiarities of the Seasat SAR data processing requirements are reviewed, along with modifications introduced for the SIR-B. An Advanced Digital SAR Processor (ADSP) is under development for use with the SIR-B in the 1986 time frame as an upgrade for the IDP, which will be in service in 1984-5.
NASA Technical Reports Server (NTRS)
Shaffer, R. M.
1973-01-01
A detailed description is given of the methods of choose the duplication film and chemistry currently used in the NASA-ERTS Ground Data Handling System. The major ERTS photographic duplication goals are given as background information to justify the specifications for the desirable film/chemistry combination. Once these specifications were defined, a quantitative evaluation program was designed and implemented to determine if any recommended combinations could meet the ERTS laboratory specifications. The specifications include tone reproduction, granularity, MTF and cosmetic effects. A complete description of the techniques used to measure the test response variables is given. It is anticipated that similar quantitative techniques could be used on other programs to determine the optimum film/chemistry consistent with the engineering goals of the program.
NASA Astrophysics Data System (ADS)
Almirall, Jose R.; Trejos, Tatiana; Hobbs, Andria; Furton, Kenneth G.
2003-09-01
The importance of small amounts of glass and paint evidence as a means to associate a crime event to a suspect or a suspect to another individual has been demonstrated in many cases. Glass is a fragile material that is often found at the scenes of crimes such as burglaries, hit-and-run accidents and violent crime offenses. Previous work has demonstrated the utility of elemental analysis by solution ICP-MS of small amounts of glass for the comparison between a fragment found at a crime scene to a possible source of the glass. The multi-element capability and the sensitivity of ICP-MS combined with the simplified sample introduction of laser ablation prior to ion detection provides for an excellent and relatively non-destructive technique for elemental analysis of glass fragments. The direct solid sample introduction technique of laser ablation (LA) is reported as an alternative to the solution method. Direct solid sampling provides several advantages over solution methods and shows great potential for a number of solid sample analyses in forensic science. The advantages of laser ablation include the simplification of sample preparation, thereby reducing the time and complexity of the analysis, the elimination of handling acid dissolution reagents such as HF and the reduction of sources of interferences in the ionization plasma. Direct sampling also provides for essentially "non-destructive" sampling due to the removal of very small amounts of sample needed for analysis. The discrimination potential of LA-ICP-MS is compared with previously reported solution ICP-MS methods using external calibration with internal standardization and a newly reported solution isotope dilution (ID) method. A total of ninety-one different glass samples were used for the comparison study using the techniques mentioned. One set consisted of forty-five headlamps taken from a variety of automobiles representing a range of twenty years of manufacturing dates. A second set consisted of forty-six automotive glasses (side windows and windshields) representing casework glass from different vehicle manufacturers over several years was also characterized by RI and elemental composition analysis. The solution sample introduction techniques (external calibration and isotope dilution) provide for excellent sensitivity and precision but have the disadvantages of destroying the sample and also involve complex sample preparation. The laser ablation method was simpler, faster and produced comparable discrimination to the EC-ICP-MS and ID-ICP-MS. LA-ICP-MS can provide for an excellent alternative to solution analysis of glass in forensic casework samples. Paints and coatings are frequently encountered as trace evidence samples submitted to forensic science laboratories. A LA-ICP-MS method has been developed to complement the commonly used techniques in forensic laboratories in order to better characterize these samples for forensic purposes. Time-resolved plots of each sample can be compared to associate samples to each other or to discriminate between samples. Additionally, the concentration of lead and the ratios of other elements have been determined in various automotive paints by the reported method. A sample set of eighteen (18) survey automotive paint samples have been analyzed with the developed method in order to determine the utility of LA-ICP-MS and to compare the method to the more commonly used scanning electron microscopy (SEM) method for elemental characterization of paint layers in forensic casework.