Sakai, Miho; Hayakawa, Yoshihiro; Funada, Yasuhiro; Ando, Takashi; Fukusaki, Eiichiro; Bamba, Takeshi
2017-09-15
In this study, we propose a novel variable sample injection system based on full-loop injection, named the split-flow sample introduction system, for application in supercritical fluid chromatography (SFC). In this system, the mobile phase is split by the differential pressure between two back pressure regulators (BPRs) after full-loop injection suitable for SFC, and this differential pressure determines the introduction rate. Nine compounds with a wide range of characteristics were introduced with high reproducibility and universality, confirming that a robust variable sample injection system was achieved. We also investigated the control factors of our proposed system. Sample introduction was controlled by the ratio between the column-side pressure drops in splitless and split flow, ΔP columnsideinsplitless and ΔP columnsideinsplit , respectively, where ΔP columnsideinsplitless is related to the mobile phase flow rate and composition and the column resistance. When all other conditions are kept constant, increasing the make-up flow induces an additional pressure drop on the column side of the system, which leads to a reduced column-side flow rate, and hence decreased the amount of sample injected, even when the net pressure drop on the column side remains the same. Thus, sample introduction could be highly controlled at low sample introduction rate, regardless of the introduction conditions. This feature is advantageous because, as a control factor, the solvent in the make-up pump is independent of the column-side pressure drop. Copyright © 2017. Published by Elsevier B.V.
Elwaer, Nagmeddin; Hintelmann, Holger
2007-11-01
The analytical performance of five sample introduction systems, a cross flow nebulizer spray chamber, two different solvent desolvation systems, a multi-mode sample introduction system (MSIS), and a hydride generation (LI2) system were compared for the determination of Se isotope ratio measurements using multi-collector inductively coupled plasma mass spectrometry (MC-ICP/MS). The optimal operating parameters for obtaining the highest Se signal-to-noise (S/N) ratios and isotope ratio precision for each sample introduction were determined. The hydride generation (LI2) system was identified as the most suitable sample introduction method yielding maximum sensitivity and precision for Se isotope ratio measurement. It provided five times higher S/N ratios for all Se isotopes compared to the MSIS, 20 times the S/N ratios of both desolvation units, and 100 times the S/N ratios produced by the conventional spray chamber sample introduction method. The internal precision achieved for the (78)Se/(82)Se ratio at 100 ng mL(-1) Se with the spray chamber, two desolvation, MSIS, and the LI2 systems coupled to MC-ICP/MS was 150, 125, 114, 13, and 7 ppm, respectively. Instrument mass bias factors (K) were calculated using an exponential law correction function. Among the five studied sample introduction systems the LI2 showed the lowest mass bias of -0.0265 and the desolvation system showed the largest bias with -0.0321.
Cao, Yupin; Deng, Biyang; Yan, Lizhen; Huang, Hongli
2017-05-15
An environmentally friendly and highly efficient gas pressure-assisted sample introduction system (GPASIS) was developed for inductively-coupled plasma mass spectrometry. A GPASIS consisting of a gas-pressure control device, a customized nebulizer, and a custom-made spray chamber was fabricated. The advantages of this GPASIS derive from its high nebulization efficiencies, small sample volume requirements, low memory effects, good precision, and zero waste emission. A GPASIS can continuously, and stably, nebulize 10% NaCl solution for more than an hour without clogging. Sensitivity, detection limits, precision, long-term stability, double charge and oxide ion levels, nebulization efficiencies, and matrix effects of the sample introduction system were evaluated. Experimental results indicated that the performance of this GPASIS, was equivalent to, or better than, those obtained by conventional sample introduction systems. This GPASIS was successfully used to determine Cd and Pb by ICP-MS in human plasma. Copyright © 2017 Elsevier B.V. All rights reserved.
Eckels, David E.; Hass, William J.
1989-05-30
A sample transport, sample introduction, and flame excitation system for spectrometric analysis of high temperature gas streams which eliminates degradation of the sample stream by condensation losses.
Sample introduction system for a flow cytometer
Van den Engh, Ger
1997-01-01
A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning, HPLC tubing and fittings may be used in a manner which facilitates removing of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it.
Sample introduction system for a flow cytometer
Engh, G. van den
1997-02-11
A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning, HPLC tubing and fittings may be used in a manner which facilitates removing of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it. 3 figs.
Klencsár, Balázs; Sánchez, Carlos; Balcaen, Lieve; Todolí, José; Lynen, Frederic; Vanhaecke, Frank
2018-05-10
A systematic evaluation of four different ICP sample introduction systems to be used in the context of metabolite profiling of chlorine-containing pharmaceuticals via HPLC-ICP-MS was carried out using diclofenac and its major metabolite, 4'-hydroxy-diclofenac, as model compounds. The strict requirements for GMP validation of chromatographic methods in the pharmaceutical industry were adhered to in this context. The final aim of this investigation is an extension of the applicability and validatability of HPLC-ICP-MS in the field of pharmaceutical R&D. Five different gradient programmes were tested while the baseline peak width (w b ), peak capacity (P), USP tailing factor (A s ) and USP signal-to-noise ratio (USP S/N) were determined as major indicators of the chromatographic performance and the values obtained were compared to the corresponding FDA recommendations (if applicable). Four different ICP-MS sample introductions systems were investigated involving two units typically working at higher flow rates (∼1.0 mL min -1 ) and another two systems working at lower flow rates (∼0.1 mL min -1 ). Optimal conditions with potential for applicability under GMP conditions were found at a mobile phase flow rate of 1.0 mL min -1 by using a pneumatic micro-flow LC nebulizer mounted onto a Peltier-cooled cyclonic spray chamber cooled to -1 °C for sample introduction. Under these conditions, HPLC-ICP-MS provided a chromatographic performance similar to that of HPLC with UV detection. The peak shape (USP tailing factor = 1.1-1.4) was significantly improved compared to that obtained with the Peltier-cooled Scott-type spray chamber. Two alternative sample introduction systems - a POINT ® and a High-Temperature Torch-Integrated Sample Introduction System (hTISIS) - were also tested at a flow rate of 0.1 mL min -1 using a chromatographic column with 1.0 mm ID. Although these systems allowed the peak shape to be improved compared to that obtained with the traditional Scott-type spray chamber, the limits of detection and of quantification achievable were strongly compromised due to the significantly lower sensitivity observed for Cl. In addition to a comparison of the aforementioned sample introduction systems, also the effect of spray chamber temperature was evaluated and it was demonstrated that proper temperature control plays an essential role in the optimization of HPLC-ICP-MS methods. Copyright © 2018 Elsevier B.V. All rights reserved.
Sample introduction apparatus for a flow cytometer
Van den Engh, Ger
1998-01-01
A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning HPLC tubing and fittings may be used in a manner which facilitates removable of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it.
Sample introduction apparatus for a flow cytometer
Van den Engh, G.
1998-03-10
A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning HPLC tubing and fittings may be used in a manner which facilitates removable of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it. 3 figs.
Optimal sampling strategies for detecting zoonotic disease epidemics.
Ferguson, Jake M; Langebrake, Jessica B; Cannataro, Vincent L; Garcia, Andres J; Hamman, Elizabeth A; Martcheva, Maia; Osenberg, Craig W
2014-06-01
The early detection of disease epidemics reduces the chance of successful introductions into new locales, minimizes the number of infections, and reduces the financial impact. We develop a framework to determine the optimal sampling strategy for disease detection in zoonotic host-vector epidemiological systems when a disease goes from below detectable levels to an epidemic. We find that if the time of disease introduction is known then the optimal sampling strategy can switch abruptly between sampling only from the vector population to sampling only from the host population. We also construct time-independent optimal sampling strategies when conducting periodic sampling that can involve sampling both the host and the vector populations simultaneously. Both time-dependent and -independent solutions can be useful for sampling design, depending on whether the time of introduction of the disease is known or not. We illustrate the approach with West Nile virus, a globally-spreading zoonotic arbovirus. Though our analytical results are based on a linearization of the dynamical systems, the sampling rules appear robust over a wide range of parameter space when compared to nonlinear simulation models. Our results suggest some simple rules that can be used by practitioners when developing surveillance programs. These rules require knowledge of transition rates between epidemiological compartments, which population was initially infected, and of the cost per sample for serological tests.
Van Berkel, Gary J.; Kertesz, Vilmos
2015-08-25
RATIONALE: A simple method to introduce unprocessed samples into a solvent for rapid characterization by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The continuous flow, self-cleaning open port sampling interface introduced here fills this void. METHODS: The open port sampling interface used a vertically aligned, co-axial tube arrangement enabling solvent delivery to the sampling end of the device through the tubing annulus and solvent aspiration down the center tube and into the mass spectrometer ionization source via the commercial APCI emitter probe. The solvent delivery rate to the interface was set to exceed the aspiration rate creatingmore » a continuous sampling interface along with a constant, self-cleaning spillover of solvent from the top of the probe. RESULTS: Using the open port sampling interface with positive ion mode APCI and a hybrid quadrupole time of flight mass spectrometer, rapid, direct sampling and analysis possibilities are exemplified with plastics, ballpoint and felt tip ink pens, skin, and vegetable oils. These results demonstrated that the open port sampling interface could be used as a simple, versatile and self-cleaning system to rapidly introduce multiple types of unprocessed, sometimes highly concentrated and complex, samples into a solvent flow stream for subsequent ionization and analysis by mass spectrometry. The basic setup presented here could be incorporated with any self-aspirating liquid introduction ionization source (e.g., ESI, APCI, APPI, ICP, etc.) or any type of atmospheric pressure sampling ready mass spectrometer system. CONCLUSIONS: The open port sampling interface provides a means to introduce and quickly analyze unprocessed solid or liquid samples with liquid introduction atmospheric pressure ionization source without fear of sampling interface or ionization source contamination.« less
Lam, C K; Zhang, Y; Busch, M A; Busch, K W
1993-06-01
A new sample introduction system for the analysis of continuously flowing liquid streams by flame infrared-emission (FIRE) spectrometry has been developed. The system uses a specially designed purge cell to strip dissolved CO(2) from solution into a hydrogen gas stream that serves as the fuel for a hydrogen/air flame. Vibrationally excited CO(2) molecules present in the flame are monitored with a simple infrared filter (4.4 mum) photometer. The new system can be used to introduce analytes as a continuous liquid stream (process analysis mode) or on a discrete basis by sample injection (flow injection analysis mode). The key to the success of the method is the new purge-cell design. The small internal volume of the cell minimizes problems associated with purge-cell clean-out and produces sharp, reproducible signals. Spent analytical solution is continuously drained from the cell, making cell disconnection and cleaning between samples unnecessary. Under the conditions employed in this study, samples could be analyzed at a maximum rate of approximately 60/h. The new sample introduction system was successfully tested in both a process analysis- and a flow injection analysis mode for the determination of total inorganic carbon in Waco tap water. For the first time, flame infrared-emission spectrometry was successfully extended to non-volatile organic compounds by using chemical pretreatment with peroxydisulfate in the presence of silver ion to convert the analytes into dissolved carbon dioxide, prior to purging and detection by the FIRE radiometer. A test of the peroxydisulfate/Ag(+) reaction using six organic acids and five sugars indicated that all 11 compounds were oxidized to nearly the same extent. Finally, the new sample introduction system was used in conjunction with a simple filter FIRE radiometer as a detection system in ion-exchange high-performance liquid chromatography. Ion-exchange chromatograms are shown for two aqueous mixtures, one containing six organic acids and the second containing six mono-, di-, and trisaccharides.
NASA Astrophysics Data System (ADS)
Mora, Juan; Gras, Luis; van Veen, Eric H.; de Loos-Vollebregt, Margaretha T. C.
1999-06-01
The analytical behaviour of an electrothermal vaporization (ETV) device for the introduction of mineral acid solutions in inductively coupled plasma mass spectrometry (ICP-MS) was evaluated. Water, nitric acid, hydrochloric acid, perchloric acid and sulphuric acid in concentrations within the 0.05-1.0 mol l-1 range were studied. For all the acids tested, increasing the acid concentration increases the ion signal and deteriorates the precision. The magnitude of the signal enhancement depends on the analyte and on the acid considered. Acid solutions give rise to ion signals that are between 2 and 10 times higher than those with water. Among the acids tested, sulphuric acid provides the highest signals. The addition of palladium reduces matrix effects due to the acids and increases the signal in ETV ICP-MS. In comparison with conventional sample nebulization (CS), the ETV sample introduction system provides higher sensitivities (between 2 and 20 times higher) at the same acid concentration. The magnitude of this improvement is similar to that obtained with a microwave desolvation system (MWDS). The ETV sample introduction system gives rise to the lowest background signals from matrix-induced species. Due to this fact, the limits of detection (LODs) obtained for the isotopes affected by any interference are lower for ETV sample introduction than those obtained with the CS and the MWDS. For the isotopes that do not suffer from matrix-induced spectral interferences, the ETV gives rise to LODs higher than those obtained with the CS. For these isotopes the lowest LODs are obtained with MWDS.
Cacho, J I; Nicolás, J; Viñas, P; Campillo, N; Hernández-Córdoba, M
2016-12-02
A solventless analytical method is proposed for analyzing the compounds responsible for cork taint in cork stoppers. Direct sample introduction (DSI) is evaluated as a sample introduction system for the gas chromatography-mass spectrometry (GC-MS) determination of four haloanisoles (HAs) in cork samples. Several parameters affecting the DSI step, including desorption temperature and time, gas flow rate and other focusing parameters, were optimized using univariate and multivariate approaches. The proposed method shows high sensitivity and minimises sample handling, with detection limits of 1.6-2.6ngg -1 , depending on the compound. The suitability of the optimized procedure as a screening method was evaluated by obtaining decision limits (CCα) and detection capabilities (CCβ) for each analyte, which were found to be in 6.9-11.8 and 8.7-14.8ngg -1 , respectively, depending on the compound. Twenty-four cork samples were analysed, and 2,4,6-trichloroanisole was found in four of them at levels between 12.6 and 53ngg -1 . Copyright © 2016 Elsevier B.V. All rights reserved.
Pfeuffer, Kevin P.; Schaper, J. Niklas; Shelley, Jacob T.; Ray, Steven J.; Chan, George C.-Y.; Bings, Nicolas H.; Hieftje, Gary M.
2013-01-01
The flowing atmospheric pressure afterglow (FAPA) is a promising new source for atmospheric pressure, ambient desorption/ionization mass spectrometry. However, problems exist with reproducible sample introduction into the FAPA source. To overcome this limitation, a new FAPA geometry has been developed in which concentric tubular electrodes are utilized to form a halo-shaped discharge; this geometry has been termed the halo-FAPA or h-FAPA. With this new geometry, it is still possible to achieve direct desorption and ionization from a surface; however, sample introduction through the inner capillary is also possible and improves interaction between the sample material (solution, vapor, or aerosol) and the plasma to promote desorption and ionization. The h-FAPA operates with a helium gas flow of 0.60 L/min outer, 0.30 L/min inner, applied current of 30 mA at 200 V for 6 watts of power. In addition, separation of the discharge proper and sample material prevents perturbations to the plasma. Optical-emission characterization and gas rotational temperatures reveal that the temperature of the discharge is not significantly affected (< 3% change at 450K) by water vapor during solution-aerosol sample introduction. The primary mass-spectral background species are protonated water clusters, and the primary analyte ions are protonated molecular ions (M+H+). Flexibility of the new ambient sampling source is demonstrated by coupling it with a laser ablation unit, a concentric nebulizer and a droplet-on-demand system for sample introduction. A novel arrangement is also presented in which the central channel of the h-FAPA is used as the inlet to a mass spectrometer. PMID:23808829
Pfeuffer, Kevin P; Schaper, J Niklas; Shelley, Jacob T; Ray, Steven J; Chan, George C-Y; Bings, Nicolas H; Hieftje, Gary M
2013-08-06
The flowing atmospheric-pressure afterglow (FAPA) is a promising new source for atmospheric-pressure, ambient desorption/ionization mass spectrometry. However, problems exist with reproducible sample introduction into the FAPA source. To overcome this limitation, a new FAPA geometry has been developed in which concentric tubular electrodes are utilized to form a halo-shaped discharge; this geometry has been termed the halo-FAPA or h-FAPA. With this new geometry, it is still possible to achieve direct desorption and ionization from a surface; however, sample introduction through the inner capillary is also possible and improves interaction between the sample material (solution, vapor, or aerosol) and the plasma to promote desorption and ionization. The h-FAPA operates with a helium gas flow of 0.60 L/min outer, 0.30 L/min inner, and applied current of 30 mA at 200 V for 6 W of power. In addition, separation of the discharge proper and sample material prevents perturbations to the plasma. Optical-emission characterization and gas rotational temperatures reveal that the temperature of the discharge is not significantly affected (<3% change at 450 K) by water vapor during solution-aerosol sample introduction. The primary mass-spectral background species are protonated water clusters, and the primary analyte ions are protonated molecular ions (M + H(+)). Flexibility of the new ambient sampling source is demonstrated by coupling it with a laser ablation unit, a concentric nebulizer, and a droplet-on-demand system for sample introduction. A novel arrangement is also presented in which the central channel of the h-FAPA is used as the inlet to a mass spectrometer.
Fréchette-Viens, Laurie; Hadioui, Madjid; Wilkinson, Kevin J
2017-01-15
The applicability of single particle ICP-MS (SP-ICP-MS) for the analysis of nanoparticle size distributions and the determination of particle numbers was evaluated using the rare earth oxide, La 2 O 3 , as a model particle. The composition of the storage containers, as well as the ICP-MS sample introduction system were found to significantly impact SP-ICP-MS analysis. While La 2 O 3 nanoparticles (La 2 O 3 NP) did not appear to interact strongly with sample containers, adsorptive losses of La 3+ (over 24h) were substantial (>72%) for fluorinated ethylene propylene bottles as opposed to polypropylene (<10%). Furthermore, each part of the sample introduction system (nebulizers made of perfluoroalkoxy alkane (PFA) or glass, PFA capillary tubing, and polyvinyl chloride (PVC) peristaltic pump tubing) contributed to La 3+ adsorptive losses. On the other hand, the presence of natural organic matter in the nanoparticle suspensions led to a decreased adsorptive loss in both the sample containers and the introduction system, suggesting that SP-ICP-MS may nonetheless be appropriate for NP analysis in environmental matrices. Coupling of an ion-exchange resin to the SP-ICP-MS led to more accurate determinations of the La 2 O 3 NP size distributions. Copyright © 2016 Elsevier B.V. All rights reserved.
MX Resident Engineer Networking Guide.
1982-04-01
FIGURES 6 INTRODUCTION ............................................................ 11 Background Approach Purpose Scope 2 SYSTEM OVERVIEW...RESIDENT ENGINEER NETWORKING GUIDE 1 INTRODUCTION Background The Network Analysis System (NAS) is not a new planning method. It has been used for more than...DEVELOPMENT RUN DATE 19MAY7’ 2359MRS S U M M A R I P A Y N L N T S S T A I I M E N I PROJECT START jAUG ?? PROJECT EXR 4 L1 SAMPLE PNOPLEM *ACTIVITT-YN
Schaper, J. Niklas; Pfeuffer, Kevin P.; Shelley, Jacob T.; Bings, Nicolas H.
2012-01-01
One of the fastest developing fields in analytical spectrochemistry in recent years is ambient desorption/ionization mass spectrometry (ADI-MS). This burgeoning interest has been due to the demonstrated advantages of the method: simple mass spectra, little or no sample preparation, and applicability to samples in the solid, liquid, or gaseous state. One such ADI-MS source, the flowing atmospheric-pressure afterglow (FAPA), is capable of direct analysis of solids just by aiming the source at the solid surface and sampling the produced ions into a mass spectrometer. However, direct introduction of significant volumes of liquid samples into this source has not been possible, as solvent loads can quench the afterglow and, thus, the formation of reagent ions. As a result, the analysis of liquid samples is preferably carried out by analyzing dried residues or by desorbing small amounts of liquid samples directly from the liquid surface. In the former case, reproducibility of sample introduction is crucial if quantitative results are desired. In the present study, introduction of liquid samples as very small droplets helps overcome the issues of sample positioning and reduced levels of solvent intake. A recently developed “drop-on-demand” (DOD) aerosol generator is capable of reproducibly producing very small volumes of liquid (~17 pL). In this paper, the coupling of FAPA-MS and DOD is reported and applications are suggested. Analytes representing different classes of substances were tested and limits of detections were determined. Matrix tolerance was investigated for drugs of abuse and their metabolites by analyzing raw urine samples and quantification without the use of internal standards. Limits of detection below 2 µg/mL, without sample pretreatment, were obtained. PMID:23025277
Schaper, J Niklas; Pfeuffer, Kevin P; Shelley, Jacob T; Bings, Nicolas H; Hieftje, Gary M
2012-11-06
One of the fastest developing fields in analytical spectrochemistry in recent years is ambient desorption/ionization mass spectrometry (ADI-MS). This burgeoning interest has been due to the demonstrated advantages of the method: simple mass spectra, little or no sample preparation, and applicability to samples in the solid, liquid, or gaseous state. One such ADI-MS source, the flowing atmospheric-pressure afterglow (FAPA), is capable of direct analysis of solids just by aiming the source at the solid surface and sampling the produced ions into a mass spectrometer. However, direct introduction of significant volumes of liquid samples into this source has not been possible, as solvent loads can quench the afterglow and, thus, the formation of reagent ions. As a result, the analysis of liquid samples is preferably carried out by analyzing dried residues or by desorbing small amounts of liquid samples directly from the liquid surface. In the former case, reproducibility of sample introduction is crucial if quantitative results are desired. In the present study, introduction of liquid samples as very small droplets helps overcome the issues of sample positioning and reduced levels of solvent intake. A recently developed "drop-on-demand" (DOD) aerosol generator is capable of reproducibly producing very small volumes of liquid (∼17 pL). In this paper, the coupling of FAPA-MS and DOD is reported and applications are suggested. Analytes representing different classes of substances were tested and limits of detections were determined. Matrix tolerance was investigated for drugs of abuse and their metabolites by analyzing raw urine samples and quantification without the use of internal standards. Limits of detection below 2 μg/mL, without sample pretreatment, were obtained.
NASA Astrophysics Data System (ADS)
Kreisberg, N. M.; Worton, D. R.; Zhao, Y.; Isaacman, G.; Goldstein, A. H.; Hering, S. V.
2014-12-01
A reliable method of sample introduction is presented for online gas chromatography with a special application to in situ field portable atmospheric sampling instruments. A traditional multi-port valve is replaced with a valveless sample introduction interface that offers the advantage of long-term reliability and stable sample transfer efficiency. An engineering design model is presented and tested that allows customizing this pressure-switching-based device for other applications. Flow model accuracy is within measurement accuracy (1%) when parameters are tuned for an ambient-pressure detector and 15% accurate when applied to a vacuum-based detector. Laboratory comparisons made between the two methods of sample introduction using a thermal desorption aerosol gas chromatograph (TAG) show that the new interface has approximately 3 times greater reproducibility maintained over the equivalent of a week of continuous sampling. Field performance results for two versions of the valveless interface used in the in situ instrument demonstrate typically less than 2% week-1 response trending and a zero failure rate during field deployments ranging up to 4 weeks of continuous sampling. Extension of the valveless interface to dual collection cells is presented with less than 3% cell-to-cell carryover.
Get with the System: General Systems Theory for Business Officials.
ERIC Educational Resources Information Center
Graczyk, Sandra L.
1993-01-01
An introduction to general systems theory and an overview of vocabulary and concepts are presented to introduce school business officials to systems thinking and to foster its use as an analytical tool. The theory is then used to analyze a sample problem: planning changes to a district's administrative computer system. (eight references) (MLF)
Bullard, K M; Hietpas, P B; Ewing, A G
1998-01-01
Polymerase chain reaction (PCR) amplified short tandem repeat (STR) samples from the HUMVWF locus have been analyzed using a unique sample introduction and separation technique. A single capillary is used to transfer samples onto an ultrathin slab gel (57 microm thin). This ultrathin nondenaturing polyacrylamide gel is used to separate the amplified fragments, and laser-induced fluorescence with ethidium bromide is used for detection. The feasibility of performing STR analysis using this system has been investigated by examining the reproducibility for repeated samples. Reproducibility is examined by comparing the migration of the 14 and 17 HUMVWF alleles on three consecutive separations on the ultrathin slab gel. Using one locus, separations match in migration time with the two alleles 42 s apart for each of the three consecutive separations. This technique shows potential to increase sample throughput in STR analysis techniques although separation resolution still needs to be improved.
Estimating the rate of biological introductions: Lessepsian fishes in the Mediterranean.
Belmaker, Jonathan; Brokovich, Eran; China, Victor; Golani, Daniel; Kiflawi, Moshe
2009-04-01
Sampling issues preclude the direct use of the discovery rate of exotic species as a robust estimate of their rate of introduction. Recently, a method was advanced that allows maximum-likelihood estimation of both the observational probability and the introduction rate from the discovery record. Here, we propose an alternative approach that utilizes the discovery record of native species to control for sampling effort. Implemented in a Bayesian framework using Markov chain Monte Carlo simulations, the approach provides estimates of the rate of introduction of the exotic species, and of additional parameters such as the size of the species pool from which they are drawn. We illustrate the approach using Red Sea fishes recorded in the eastern Mediterranean, after crossing the Suez Canal, and show that the two approaches may lead to different conclusions. The analytical framework is highly flexible and could provide a basis for easy modification to other systems for which first-sighting data on native and introduced species are available.
Søndergaard, Jens; Asmund, Gert; Larsen, Martin M.
2015-01-01
Trace element determination in seawater is analytically challenging due to the typically very low concentrations of the trace elements and the potential interference of the salt matrix. A common way to address the challenge is to pre-concentrate the trace elements on a chelating resin, then rinse the matrix elements from the resin and subsequently elute and detect the trace elements using inductively coupled plasma mass spectrometry (ICP-MS). This technique typically involves time-consuming pre-treatment of the samples for ‘off-line’ analyses or complicated sample introduction systems involving several pumps and valves for ‘on-line’ analyses. As an alternative, the following method offers a simple method for ‘on-line’ analyses of seawater by ICP-MS. As opposed to previous methods, excess seawater was pumped through the nebulizer of the ICP-MS during the pre-concentration step but the gas flow was adjusted so that the seawater was pumped out as waste without being sprayed into the instrument. Advantages of the method include: • Simple and convenient analyses of seawater requiring no changes to the ‘standard’ sample introduction system except from a resin-filled micro-column connected to the sample tube. The ‘standard’ sample introduction system refers to that used for routine digest-solution analyses of biota and sediment by ICP-MS using only one peristaltic pump; and • Accurate determination of the elements V, Mn, Co, Ni, Cu, Zn, Cd and Pb in a range of different seawater matrices verified by participation in 6 successive rounds of the international laboratory intercalibration program QUASIMEME. PMID:26258050
NASA Astrophysics Data System (ADS)
Sánchez, Raquel; Cañabate, Águeda; Bresson, Carole; Chartier, Frédéric; Isnard, Hélène; Maestre, Salvador; Nonell, Anthony; Todolí, José-Luis
2017-03-01
This work describes for the first time the comparison of the analytical performances obtained with a high temperature torch integrated sample introduction system (hTISIS) against those found with a commercially available desolvation system (APEX) associated with inductively coupled plasma mass spectrometry (ICP-MS). A double pass spray chamber was taken as the reference system. Similar detection limits and sensitivities were obtained in continuous injection mode at low liquid flow rates for the APEX and hTISIS operating at high temperatures. In contrast, in the air-segmented injection mode, the detection limits obtained with hTISIS at high temperatures were up to 12 times lower than those found for the APEX. Regarding memory effects, wash out times were shorter in continuous mode and peaks were narrower in air segmented mode for the hTISIS as compared to the APEX. Non spectral interferences (matrix effects) were studied with 10% nitric acid, 2% methanol, for an ICP multielemental solution and a hydro-organic matrix containing 70% (v/v) acetonitrile in water, 15 mmol L- 1 ammonium acetate and 0.5% formic acid containing lanthanide complexes. In all the cases, matrix effects were less severe for the hTISIS operating at 200 °C and the APEX than for the double pass spray chamber. Finally, two spiked reference materials (sea water and Antartic krill) were analyzed. The hTISIS operating at 200 °C gave the best results compared to those obtained with the APEX and the double pass spray chamber. In conclusion, despite the simplicity of the hTISIS, it provided, at low liquid flow rates, results similar to or better than those obtained with the by other sample introduction systems.
Moore, Matthew R.; Pryor, Marsha; Fields, Barry; Lucas, Claressa; Phelan, Maureen; Besser, Richard E.
2006-01-01
Legionnaires' disease (LD) outbreaks are often traced to colonized potable water systems. We collected water samples from potable water systems of 96 buildings in Pinellas County, Florida, between January and April 2002, during a time when chlorine was the primary residual disinfectant, and from the same buildings between June and September 2002, immediately after monochloramine was introduced into the municipal water system. Samples were cultured for legionellae and amoebae using standard methods. We determined predictors of Legionella colonization of individual buildings and of individual sampling sites. During the chlorine phase, 19 (19.8%) buildings were colonized with legionellae in at least one sampling site. During the monochloramine phase, six (6.2%) buildings were colonized. In the chlorine phase, predictors of Legionella colonization included water source (source B compared to all others, adjusted odds ratio [aOR], 6.7; 95% confidence interval [CI], 2.0 to 23) and the presence of a system with continuously circulating hot water (aOR, 9.8; 95% CI, 1.9 to 51). In the monochloramine phase, there were no predictors of individual building colonization, although we observed a trend toward greater effectiveness of monochloramine in hotels and single-family homes than in county government buildings. The presence of amoebae predicted Legionella colonization at individual sampling sites in both phases (OR ranged from 15 to 46, depending on the phase and sampling site). The routine introduction of monochloramine into a municipal drinking water system appears to have reduced colonization by Legionella spp. in buildings served by the system. Monochloramine may hold promise as community-wide intervention for the prevention of LD. PMID:16391067
Vitellogenin (Vg) gene expression in adult male fathead minnows (FHM) has previously been used successfully to detect exposures to estrogenic compounds in aquatic systems; however, sample volume(s)required for >24h exposure durations and the logistics of sampling pose some limita...
Digital signal conditioning for flight test instrumentation
NASA Technical Reports Server (NTRS)
Bever, Glenn A.
1991-01-01
An introduction to digital measurement processes on aircraft is provided. Flight test instrumentation systems are rapidly evolving from analog-intensive to digital intensive systems, including the use of onboard digital computers. The topics include measurements that are digital in origin, as well as sampling, encoding, transmitting, and storing data. Particular emphasis is placed on modern avionic data bus architectures and what to be aware of when extracting data from them. Examples of data extraction techniques are given. Tradeoffs between digital logic families, trends in digital development, and design testing techniques are discussed. An introduction to digital filtering is also covered.
78 FR 20844 - Airworthiness Directives; Bombardier, Inc. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-08
... limitation tasks. We are proposing this AD to prevent flap system failure, and consequent reduced landing performance of the airplane. DATES: We must receive comments on this proposed AD by May 23, 2013. ADDRESSES..., through an actuator sampling program, the performance of the flap system since the introduction of...
NASA Technical Reports Server (NTRS)
1983-01-01
Reporting software programs provide formatted listings and summary reports of the Software Engineering Laboratory (SEL) data base contents. The operating procedures and system information for 18 different reporting software programs are described. Sample output reports from each program are provided.
An improved light hydrocarbon analysis system. Interim report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lamontagne, R.A.
1982-05-11
A system for extracting and measuring ambient levels of C1-C4 hydrocarbons and carbon monoxide (CO) in seawater is described. The analytical instrument is a gas chromatograph with flame ionization detectors that incorporates a catalytic conversion of CO to CH4 (methane). The samples are concentrated prior to introduction to the chromatographic system. The volatile hydrocarbons are extracted from the seawater by the use of a helium flow stream and concentrated on dry ice-acetone cold traps. Air samples can be processed in a similar way.
Multisystem altruistic metadynamics—Well-tempered variant
NASA Astrophysics Data System (ADS)
Hošek, Petr; Kříž, Pavel; Toulcová, Daniela; Spiwok, Vojtěch
2017-03-01
Metadynamics method has been widely used to enhance sampling in molecular simulations. Its original form suffers two major drawbacks, poor convergence in complex (especially biomolecular) systems and its serial nature. The first drawback has been addressed by introduction of a convergent variant known as well-tempered metadynamics. The second was addressed by introduction of a parallel multisystem metadynamics referred to as altruistic metadynamics. Here, we combine both approaches into well-tempered altruistic metadynamics. We provide mathematical arguments and trial simulations to show that it accurately predicts free energy surfaces.
Multisystem altruistic metadynamics-Well-tempered variant.
Hošek, Petr; Kříž, Pavel; Toulcová, Daniela; Spiwok, Vojtěch
2017-03-28
Metadynamics method has been widely used to enhance sampling in molecular simulations. Its original form suffers two major drawbacks, poor convergence in complex (especially biomolecular) systems and its serial nature. The first drawback has been addressed by introduction of a convergent variant known as well-tempered metadynamics. The second was addressed by introduction of a parallel multisystem metadynamics referred to as altruistic metadynamics. Here, we combine both approaches into well-tempered altruistic metadynamics. We provide mathematical arguments and trial simulations to show that it accurately predicts free energy surfaces.
2015-01-01
A hybrid microchip/capillary electrophoresis (CE) system was developed to allow unbiased and lossless sample loading and high-throughput repeated injections. This new hybrid CE system consists of a poly(dimethylsiloxane) (PDMS) microchip sample injector featuring a pneumatic microvalve that separates a sample introduction channel from a short sample loading channel, and a fused-silica capillary separation column that connects seamlessly to the sample loading channel. The sample introduction channel is pressurized such that when the pneumatic microvalve opens briefly, a variable-volume sample plug is introduced into the loading channel. A high voltage for CE separation is continuously applied across the loading channel and the fused-silica capillary separation column. Analytes are rapidly separated in the fused-silica capillary, and following separation, high-sensitivity MS detection is accomplished via a sheathless CE/ESI-MS interface. The performance evaluation of the complete CE/ESI-MS platform demonstrated that reproducible sample injection with well controlled sample plug volumes could be achieved by using the PDMS microchip injector. The absence of band broadening from microchip to capillary indicated a minimum dead volume at the junction. The capabilities of the new CE/ESI-MS platform in performing high-throughput and quantitative sample analyses were demonstrated by the repeated sample injection without interrupting an ongoing separation and a linear dependence of the total analyte ion abundance on the sample plug volume using a mixture of peptide standards. The separation efficiency of the new platform was also evaluated systematically at different sample injection times, flow rates, and CE separation voltages. PMID:24865952
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelly, Ryan T.; Wang, Chenchen; Rausch, Sarah J.
2014-07-01
A hybrid microchip/capillary CE system was developed to allow unbiased and lossless sample loading and high throughput repeated injections. This new hybrid CE system consists of a polydimethylsiloxane (PDMS) microchip sample injector featuring a pneumatic microvalve that separates a sample introduction channel from a short sample loading channel and a fused silica capillary separation column that connects seamlessly to the sample loading channel. The sample introduction channel is pressurized such that when the pneumatic microvalve opens briefly, a variable-volume sample plug is introduced into the loading channel. A high voltage for CE separation is continuously applied across the loading channelmore » and the fused silica capillary separation column. Analytes are rapidly separated in the fused silica capillary with high resolution. High sensitivity MS detection after CE separation is accomplished via a sheathless CE/ESI-MS interface. The performance evaluation of the complete CE/ESI-MS platform demonstrated that reproducible sample injection with well controlled sample plug volumes could be achieved by using the PDMS microchip injector. The absence of band broadening from microchip to capillary indicated a minimum dead volume at the junction. The capabilities of the new CE/ESI-MS platform in performing high throughput and quantitative sample analyses were demonstrated by the repeated sample injection without interrupting an ongoing separation and a good linear dependence of the total analyte ion abundance on the sample plug volume using a mixture of peptide standards. The separation efficiency of the new platform was also evaluated systematically at different sample injection times, flow rates and CE separation voltages.« less
Miyashita, Shin-Ichi; Mitsuhashi, Hiroaki; Fujii, Shin-Ichiro; Takatsu, Akiko; Inagaki, Kazumi; Fujimoto, Toshiyuki
2017-02-01
In order to facilitate reliable and efficient determination of both the particle number concentration (PNC) and the size of nanoparticles (NPs) by single-particle ICP-MS (spICP-MS) without the need to correct for the particle transport efficiency (TE, a possible source of bias in the results), a total-consumption sample introduction system consisting of a large-bore, high-performance concentric nebulizer and a small-volume on-axis cylinder chamber was utilized. Such a system potentially permits a particle TE of 100 %, meaning that there is no need to include a particle TE correction when calculating the PNC and the NP size. When the particle TE through the sample introduction system was evaluated by comparing the frequency of sharp transient signals from the NPs in a measured NP standard of precisely known PNC to the particle frequency for a measured NP suspension, the TE for platinum NPs with a nominal diameter of 70 nm was found to be very high (i.e., 93 %), and showed satisfactory repeatability (relative standard deviation of 1.0 % for four consecutive measurements). These results indicated that employing this total consumption system allows the particle TE correction to be ignored when calculating the PNC. When the particle size was determined using a solution-standard-based calibration approach without an NP standard, the particle diameters of platinum and silver NPs with nominal diameters of 30-100 nm were found to agree well with the particle diameters determined by transmission electron microscopy, regardless of whether a correction was performed for the particle TE. Thus, applying the proposed system enables NP size to be accurately evaluated using a solution-standard-based calibration approach without the need to correct for the particle TE.
NASA Astrophysics Data System (ADS)
Kreisberg, N. M.; Worton, D. R.; Zhao, Y.; Isaacman, G.; Goldstein, A. H.; Hering, S. V.
2014-07-01
A reliable method of sample introduction is presented for on-line gas chromatography with a special application to in-situ field portable atmospheric sampling instruments. A traditional multi-port valve is replaced with a controlled pressure switching device that offers the advantage of long term reliability and stable sample transfer efficiency. An engineering design model is presented and tested that allows customizing the interface for other applications. Flow model accuracy is within measurement accuracy (1%) when parameters are tuned for an ambient detector and 15% accurate when applied to a vacuum based detector. Laboratory comparisons made between the two methods of sample introduction using a thermal desorption aerosol gas chromatograph (TAG) show approximately three times greater reproducibility maintained over the equivalent of a week of continuous sampling. Field performance results for two versions of the valveless interface used in the in-situ instrument demonstrate minimal trending and a zero failure rate during field deployments ranging up to four weeks of continuous sampling. Extension of the VLI to dual collection cells is presented with less than 3% cell-to-cell carry-over.
Van Berkel, Gary J.; Kertesz, Vilmos
2016-11-15
An “Open Access”-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendorprovided software libraries. Sample classification based on spectral comparison utilized themore » spectral contrast angle method. As a result, using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. In conclusion, this work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Berkel, Gary J.; Kertesz, Vilmos
An “Open Access”-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendorprovided software libraries. Sample classification based on spectral comparison utilized themore » spectral contrast angle method. As a result, using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. In conclusion, this work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching.« less
Continuous Liquid-Sample Introduction for Bunsen Burner Atomic Emission Spectrometry.
ERIC Educational Resources Information Center
Smith, Gregory D.; And Others
1995-01-01
Describes a laboratory-constructed atomic emission spectrometer with modular instrumentation components and a simple Bunsen burner atomizer with continuous sample introduction. A schematic diagram and sample data are provided. (DDR)
Identifying Immune Drivers of Gulf War Illness Using a Novel Daily Sampling Approach
2017-10-01
AWARD NUMBER: W81XWH-12-1-0557 TITLE: Identifying Immune Drivers of Gulf War Illness Using a Novel Daily Sampling Approach PRINCIPAL...TITLE AND SUBTITLE Identifying Immune Drivers of Gulf War Illness Using A Novel 5a. CONTRACT NUMBER Daily Sampling Approach 5b. GRANT NUMBER...INTRODUCTION: The major aim of this research project is to identify aspects of the immune system that are dysregulated in veterans with Gulf War Illness
Networked event-triggered control: an introduction and research trends
NASA Astrophysics Data System (ADS)
Mahmoud, Magdi S.; Sabih, Muhammad
2014-11-01
A physical system can be studied as either continuous time or discrete-time system depending upon the control objectives. Discrete-time control systems can be further classified into two categories based on the sampling: (1) time-triggered control systems and (2) event-triggered control systems. Time-triggered systems sample states and calculate controls at every sampling instant in a periodic fashion, even in cases when states and calculated control do not change much. This indicates unnecessary and useless data transmission and computation efforts of a time-triggered system, thus inefficiency. For networked systems, the transmission of measurement and control signals, thus, cause unnecessary network traffic. Event-triggered systems, on the other hand, have potential to reduce the communication burden in addition to reducing the computation of control signals. This paper provides an up-to-date survey on the event-triggered methods for control systems and highlights the potential research directions.
Inductively Coupled Plasma Optical Emission Spectrometry for Rare Earth Elements Analysis
NASA Astrophysics Data System (ADS)
He, Man; Hu, Bin; Chen, Beibei; Jiang, Zucheng
2017-01-01
Inductively coupled plasma optical emission spectrometry (ICP-OES) merits multielements capability, high sensitivity, good reproducibility, low matrix effect and wide dynamic linear range for rare earth elements (REEs) analysis. But the spectral interference in trace REEs analysis by ICP-OES is a serious problem due to the complicated emission spectra of REEs, which demands some correction technology including interference factor method, derivative spectrum, Kalman filtering algorithm and partial least-squares (PLS) method. Matrix-matching calibration, internal standard, correction factor and sample dilution are usually employed to overcome or decrease the matrix effect. Coupled with various sample introduction techniques, the analytical performance of ICP-OES for REEs analysis would be improved. Compared with conventional pneumatic nebulization (PN), acid effect and matrix effect are decreased to some extent in flow injection ICP-OES, with higher tolerable matrix concentration and better reproducibility. By using electrothermal vaporization as sample introduction system, direct analysis of solid samples by ICP-OES is achieved and the vaporization behavior of refractory REEs with high boiling point, which can easily form involatile carbides in the graphite tube, could be improved by using chemical modifier, such as polytetrafluoroethylene and 1-phenyl-3-methyl-4-benzoyl-5-pyrazone. Laser ablation-ICP-OES is suitable for the analysis of both conductive and nonconductive solid samples, with the absolute detection limit of ng-pg level and extremely low sample consumption (0.2 % of that in conventional PN introduction). ICP-OES has been extensively employed for trace REEs analysis in high-purity materials, and environmental and biological samples.
Kreisberg, N. M.; Worton, D. R.; Zhao, Y.; ...
2014-12-12
A reliable method of sample introduction is presented for online gas chromatography with a special application to in situ field portable atmospheric sampling instruments. A traditional multi-port valve is replaced with a valveless sample introduction interface that offers the advantage of long-term reliability and stable sample transfer efficiency. An engineering design model is presented and tested that allows customizing this pressure-switching-based device for other applications. Flow model accuracy is within measurement accuracy (1%) when parameters are tuned for an ambient-pressure detector and 15% accurate when applied to a vacuum-based detector. Laboratory comparisons made between the two methods of sample introductionmore » using a thermal desorption aerosol gas chromatograph (TAG) show that the new interface has approximately 3 times greater reproducibility maintained over the equivalent of a week of continuous sampling. Field performance results for two versions of the valveless interface used in the in situ instrument demonstrate typically less than 2% week -1 response trending and a zero failure rate during field deployments ranging up to 4 weeks of continuous sampling. Extension of the valveless interface to dual collection cells is presented with less than 3% cell-to-cell carryover.« less
Application of automation and information systems to forensic genetic specimen processing.
Leclair, Benoît; Scholl, Tom
2005-03-01
During the last 10 years, the introduction of PCR-based DNA typing technologies in forensic applications has been highly successful. This technology has become pervasive throughout forensic laboratories and it continues to grow in prevalence. For many criminal cases, it provides the most probative evidence. Criminal genotype data banking and victim identification initiatives that follow mass-fatality incidents have benefited the most from the introduction of automation for sample processing and data analysis. Attributes of offender specimens including large numbers, high quality and identical collection and processing are ideal for the application of laboratory automation. The magnitude of kinship analysis required by mass-fatality incidents necessitates the application of computing solutions to automate the task. More recently, the development activities of many forensic laboratories are focused on leveraging experience from these two applications to casework sample processing. The trend toward increased prevalence of forensic genetic analysis will continue to drive additional innovations in high-throughput laboratory automation and information systems.
Van Berkel, Gary J; Kertesz, Vilmos
2017-02-15
An "Open Access"-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendor-provided software libraries. Sample classification based on spectral comparison utilized the spectral contrast angle method. Using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. This work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA.
García, Miriam; Aguirre, Miguel Ángel; Canals, Antonio
2017-09-01
In this work, a new and simple analytical methodology based on in-chamber chemical vapor generation has been developed for the spectrochemical analysis of commercial fuel samples. A multiple nebulizer with three nebulization units has been employed for this purpose: One unit was used for sample introduction, while the other two were used for the necessary reagent introduction. In this way, the aerosols were mixed inside the spray chamber. Through this method, analyte transport and, therefore, sensitivity are improved in inductively coupled plasma-optical emission spectrometry. The factors (i.e., variables), influencing chemical vapor generation, have been optimized using a multivariate approach. Under optimum chemical vapor generation conditions ([NaBH 4 ] = 1.39%, [HCl] = 2.97 M, total liquid flow = 936 μL min -1 ), the proposed sample introduction system allowed the determination of arsenic, selenium, and mercury up to 5 μg g -1 with a limit of detection of 25, 140, and 13 μg kg -1 , respectively. Analyzing spiked commercial fuel samples, recovery values obtained were between 96 and 113%, and expanded uncertainty values ranged from 4 to 16%. The most striking practical conclusion of this investigation is that no carbon deposit appears on the plasma torch after extended periods of working. Graphical abstract A new and simple analytical methodology based on in-chamber chemical vapor generation has been developed for the spectrochemical analysis of commercial fuel samples in ICP OES.
Pinsent, Amy; Blake, Isobel M; White, Michael T; Riley, Steven
2014-08-01
Both high and low pathogenic subtype A avian influenza remain ongoing threats to the commercial poultry industry globally. The emergence of a novel low pathogenic H7N9 lineage in China presents itself as a new concern to both human and animal health and may necessitate additional surveillance in commercial poultry operations in affected regions. Sampling data was simulated using a mechanistic model of H7N9 influenza transmission within commercial poultry barns together with a stochastic observation process. Parameters were estimated using maximum likelihood. We assessed the probability of detecting an outbreak at time of slaughter using both real-time polymerase chain reaction (rt-PCR) and a hemagglutinin inhibition assay (HI assay) before considering more intense sampling prior to slaughter. The day of virus introduction and R0 were estimated jointly from weekly flock sampling data. For scenarios where R0 was known, we estimated the day of virus introduction into a barn under different sampling frequencies. If birds were tested at time of slaughter, there was a higher probability of detecting evidence of an outbreak using an HI assay compared to rt-PCR, except when the virus was introduced <2 weeks before time of slaughter. Prior to the initial detection of infection N sample = 50 (1%) of birds were sampled on a weekly basis once, but after infection was detected, N sample = 2000 birds (40%) were sampled to estimate both parameters. We accurately estimated the day of virus introduction in isolation with weekly and 2-weekly sampling. A strong sampling effort would be required to infer both the day of virus introduction and R0. Such a sampling effort would not be required to estimate the day of virus introduction alone once R0 was known, and sampling N sample = 50 of birds in the flock on a weekly or 2 weekly basis would be sufficient.
Microplasmas for chemical analysis: analytical tools or research toys?
NASA Astrophysics Data System (ADS)
Karanassios, Vassili
2004-07-01
An overview of the activities of the research groups that have been involved in fabrication, development and characterization of microplasmas for chemical analysis over the last few years is presented. Microplasmas covered include: miniature inductively coupled plasmas (ICPs); capacitively coupled plasmas (CCPs); microwave-induced plasmas (MIPs); a dielectric barrier discharge (DBD); microhollow cathode discharge (MCHD) or microstructure electrode (MSE) discharges, other microglow discharges (such as those formed between "liquid" electrodes); microplasmas formed in micrometer-diameter capillary tubes for gas chromatography (GC) or high-performance liquid chromatography (HPLC) applications, and a stabilized capacitive plasma (SCP) for GC applications. Sample introduction into microplasmas, in particular, into a microplasma device (MPD), battery operation of a MPD and of a mini- in-torch vaporization (ITV) microsample introduction system for MPDs, and questions of microplasma portability for use on site (e.g., in the field) are also briefly addressed using examples of current research. To emphasize the significance of sample introduction into microplasmas, some previously unpublished results from the author's laboratory have also been included. And an overall assessment of the state-of-the-art of analytical microplasma research is provided.
Business Student Computer Self-Efficacy: Ten Years Later
ERIC Educational Resources Information Center
Karsten, Rex; Schmidt, Dennis
2008-01-01
This study analyzes computer self-efficacy for two independent samples of students enrolled in an introduction to information systems course in 1996 and 2006. We administered two validated and frequently employed measures of general computer self-efficacy to each group of students and collected demographic and computer-use data. Our findings…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanamura, S.; Smith, B.W.; Winefordner, J.D.
1983-11-01
By means of thermal vaporization, inorganic, organic, and metallorganic species are separated and elemental emission in a microwave plasma is detected as a function of vaporization temperature. Solid samples of 250 mg or more are used to avoid problems with sample heterogeneity. The precision of characteristic appearance temperatures is +/-2/sup 0/C. The single electrode atmosphere pressure microwave plasma system is extremely tolerant to the introduction of water, organic solvents, and air. The measurement system contained a repetition wavelength scan device to allow background correction. The plasma temperature was 5500 K. The system was used to measure C, H, N, O,more » and Hg in orchard leaves and in tuna fish. 9 figures, 5 tables.« less
Mvundura, Mercy; Kien, Vu Duy; Nga, Nguyen Tuyet; Robertson, Joanie; Cuong, Nguyen Van; Tung, Ho Thanh; Hong, Duong Thi; Levin, Carol
2014-02-07
Few studies document the costs of operating vaccine supply chains, but decision-makers need this information to inform cost projections for investments to accommodate new vaccine introduction. This paper presents empirical estimates of vaccine supply chain costs for Vietnam's Expanded Program on Immunization (EPI) for routine vaccines at each level of the supply chain, before and after the introduction of the pentavalent vaccine. We used micro-costing methods to collect resource-use data associated with storage and transportation of vaccines and immunization supplies at the national store, the four regional stores, and a sample of provinces, districts, and commune health centers. We collected stock ledger data on the total number of doses of vaccines handled by each facility during the assessment year. Total supply chain costs were estimated at approximately US$65,000 at the national store and an average of US$39,000 per region, US$5800 per province, US$2200 per district, and US$300 per commune health center. Across all levels, cold chain equipment capital costs and labor were the largest drivers of costs. The cost per dose delivered was estimated at US$0.19 before the introduction of pentavalent and US$0.24 cents after introduction. At commune health centers, supply chain costs were 104% of the value of vaccines before introduction of pentavalent vaccine and 24% after introduction, mainly due to the higher price per dose of the pentavalent vaccine. The aggregated costs at the last tier of the health system can be substantial because of the large number of facilities. Even in countries with high-functioning systems, empirical evidence on current costs from all levels of the system can help estimate resource requirements for expanding and strengthening resources to meet future immunization program needs. Other low- and middle-income countries can benefit from similar studies, in view of new vaccine introductions that will put strains on existing systems. Copyright © 2013 Elsevier Ltd. All rights reserved.
Zou, Nan; Chen, Ronghua; Qin, Yuhong; Song, Shuangyu; Tang, Xinglin; Pan, Canping
2016-09-01
Analytical methods based on multiplug filtration cleanup coupled with pulse glow discharge-ion mobility spectrometry and liquid chromatography tandem mass spectrometry were developed for the analysis of tricaine mesylate residue in fish and fish-raising water samples. A silica fiber holder and an appropriate new interface were designed to make the direct introduction of the fiber into the pulse glow discharge-ion mobility spectrometry introduction mechanism. The multiplug filtration cleanup method with adsorption mixtures was optimized for the determination of tricaine mesylate in fish samples. Good linear relationships were obtained by the two methods. For fish samples, limits of detection were 6 and 0.6 μg/kg by ion mobility spectrometry and liquid chromatography with tandem mass spectrometry, respectively. The matrix effect of the established liquid chromatography tandem mass spectrometry method was negligible for fish samples but that of the ion mobility spectrometry method was not. The two methods were compared. The ion mobility spectrometry system could be used a rapid screening tool on site with the advantage of rapidity, simplicity, and portability, and the liquid chromatography tandem mass spectrometry system could be used for validation in laboratory conditions with the advantage of lower limit of detection, stability, and precision. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Technical Reports Server (NTRS)
Heinemann, K.; Poppa, H.
1986-01-01
A commercial transmission electron microscope (TEM), with flat-plate upper pole piece configuration of the objective lens, and top-entry specimen introduction was modified by introducing an ultrahigh vacuum (UHV) specimen chamber for in situ TEM experimentation. The pumping and design principles and special features of this UHV chamber, which makes it possible to obtain 5 x 10 to the -10th mbar pressure at the site of the specimen, while maintaining the airlock system that allows operation in the 10 to the -10th mbar range within 15 min after specimen change, are described. Design operating pressures and image quality (resolution of metal particles smaller than 1 nm in size) were achieved. Schematic drawings and design dimensions are included.
How Does Early Feedback in an Online Programming Course Change Problem Solving?
ERIC Educational Resources Information Center
Ebrahimi, Alireza
2012-01-01
How does early feedback change the programming problem solving in an online environment and help students choose correct approaches? This study was conducted in a sample of students learning programming in an online course entitled Introduction to C++ and OOP (Object Oriented Programming) using the ANGEL learning management system platform. My…
Thermoelectric technique to precisely control hyperthermic exposures of human whole blood.
DuBose, D A; Langevin, R C; Morehouse, D H
1996-12-01
The need in military research to avoid exposing humans to harsh environments and reduce animal use requires the development of in vitro models for the study of hyperthermic injury. A thermoelectric module (TEM) system was employed to heat human whole blood (HWB) in a manner similar to that experienced by heat-stroked rats. This system precisely and accurately replicated mild, moderate, and extreme heat-stress exposures. Temperature changes could be monitored without the introduction of a test sample thermistor, which reduced contamination problems. HWB with hematocrits of 45 or 50% had similar heating curves, indicating that the system compensated for differences in sample character. The unit's size permitted its containment within a standard carbon dioxide incubator to further control sample environment. These results indicate that the TEM system can precisely control temperature change in this heat stress in vitro model employing HWB. Information obtained from such a model could contribute to military preparedness.
Organophosphate flame retardants in household dust before and after introduction of new furniture.
Keimowitz, A R; Strunsky, N; Wovkulich, K
2016-04-01
Flame retardant compounds originating from household items collect in household dust, a reasonable proxy for human exposure. Contributions of specific items or behaviors to dust are difficult to separate. This study examined standardized college housing before and after the introduction of new, flame retardant couches in order to explore any effect that changing upholstered furniture may have on flame retardant concentrations in dust. Two contradictory hypotheses were posited: (1) that new furniture might increase flame retardant releases immediately after introduction due to initial off-gassing of new materials or (2) that older furniture would release more flame retardants due to mechanical breakdown of polyurethane foam. This study was designed to determine which of these processes dominated. Prior to the introduction of new furniture, TDCIPP was detected in 12/20 samples at a median concentration of 22 μg/g and TCEP was detected in 1/20 samples at a concentration of 16 μg/g. TDCIPP and TCEP were not detected in any samples (N = 29) after the introduction of new couches. TPHP was detected both before (in 11/20 samples) and after (in 5/29 samples) introduction of new couches; the median concentrations before and after were 63 ± 49 and 16 ± 11 μg/g (standard deviation shown). Introduced couches contained TDCIPP (and not TPHP) at ∼1.25% (w/w). These data support the second hypothesis and indicate that removal of older furniture decreases TDCIPP and TCEP concentrations in dust and may potentially reduce total flame retardant concentrations in dust, at least immediately after introduction of the new furniture. Copyright © 2016 Elsevier Ltd. All rights reserved.
Electronic Tongue—A Tool for All Tastes?
Podrażka, Marta; Bączyńska, Ewa; Kundys, Magdalena; Jeleń, Paulina S.; Witkowska Nery, Emilia
2017-01-01
Electronic tongue systems are traditionally used to analyse: food products, water samples and taste masking technologies for pharmaceuticals. In principle, their applications are almost limitless, as they are able to almost completely reduce the impact of interferents and can be applied to distinguish samples of extreme complexity as for example broths from different stages of fermentation. Nevertheless, their applications outside the three principal sample types are, in comparison, rather scarce. In this review, we would like to take a closer look on what are real capabilities of electronic tongue systems, what can be achieved using mixed sensor arrays and by introduction of biosensors or molecularly imprinted polymers in the matrix. We will discuss future directions both in the sense of applications as well as system development in the ever-growing trend of low cost analysis. PMID:29301230
NASA Astrophysics Data System (ADS)
Suzuki, Yoshinari; Sato, Hikaru; Hiyoshi, Katsuhiro; Furuta, Naoki
2012-10-01
A new calibration system for real-time determination of trace elements in airborne particulates was developed. Airborne particulates were directly introduced into an inductively coupled plasma mass spectrometer, and the concentrations of 15 trace elements were determined by means of an external calibration method. External standard solutions were nebulized by an ultrasonic nebulizer (USN) coupled with a desolvation system, and the resulting aerosol was introduced into the plasma. The efficiency of sample introduction via the USN was calculated by two methods: (1) the introduction of a Cr standard solution via the USN was compared with introduction of a Cr(CO)6 standard gas via a standard gas generator and (2) the aerosol generated by the USN was trapped on filters and then analyzed. The Cr introduction efficiencies obtained by the two methods were the same, and the introduction efficiencies of the other elements were equal to the introduction efficiency of Cr. Our results indicated that our calibration method for introduction efficiency worked well for the 15 elements (Ti, V, Cr, Mn, Co, Ni, Cu, Zn, As, Mo, Sn, Sb, Ba, Tl and Pb). The real-time data and the filter-collection data agreed well for elements with low-melting oxides (V, Co, As, Mo, Sb, Tl, and Pb). In contrast, the real-time data were smaller than the filter-collection data for elements with high-melting oxides (Ti, Cr, Mn, Ni, Cu, Zn, Sn, and Ba). This result implies that the oxides of these 8 elements were not completely fused, vaporized, atomized, and ionized in the initial radiation zone of the inductively coupled plasma. However, quantitative real-time monitoring can be realized after correction for the element recoveries which can be calculated from the ratio of real-time data/filter-collection data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farmer, Orville T.; Olsen, Khris B.; Thomas, May-Lin P.
2008-05-01
A method for the separation and determination of total and isotopic uranium and plutonium by ICP-MS was developed for IAEA samples on cellulose-based media. Preparation of the IAEA samples involved a series of redox chemistries and separations using TRU® resin (Eichrom). The sample introduction system, an APEX nebulizer (Elemental Scientific, Inc), provided enhanced nebulization for a several-fold increase in sensitivity and reduction in background. Application of mass bias (ALPHA) correction factors greatly improved the precision of the data. By combining the enhancements of chemical separation, instrumentation and data processing, detection levels for uranium and plutonium approached high attogram levels.
Makrlíková, Anna; Opekar, František; Tůma, Petr
2015-08-01
A computer-controlled hydrodynamic sample introduction method has been proposed for short-capillary electrophoresis. In the method, the BGE flushes sample from the loop of a six-way sampling valve and is carried to the injection end of the capillary. A short pressure impulse is generated in the electrolyte stream at the time when the sample zone is at the capillary, leading to injection of the sample into the capillary. Then the electrolyte flow is stopped and the separation voltage is turned on. This way of sample introduction does not involve movement of the capillary and both of its ends remain constantly in the solution during both sample injection and separation. The amount of sample introduced to the capillary is controlled by the duration of the pressure pulse. The new sample introduction method was tested in the determination of ammonia, creatinine, uric acid, and hippuric acid in human urine. The determination was performed in a capillary with an overall length of 10.5 cm, in two BGEs with compositions 50 mM MES + 5 mM NaOH (pH 5.1) and 1 M acetic acid + 1.5 mM crown ether 18-crown-6 (pH 2.4). A dual contactless conductivity/UV spectrometric detector was used for the detection. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Larsen, Erik H.
1998-02-01
Achievement of optimum selectivity, sensitivity and robustness in speciation analysis using high performance liquid chromatography (HPLC) with inductively coupled mass spectrometry (ICP-MS) detection requires that each instrumental component is selected and optimized with a view to the ideal operating characteristics of the entire hyphenated system. An isocratic HPLC system, which employs an aqueous mobile phase with organic buffer constituents, is well suited for introduction into the ICP-MS because of the stability of the detector response and high degree of analyte sensitivity attained. Anion and cation exchange HPLC systems, which meet these requirements, were used for the seperation of selenium and arsenic species in crude extracts of biological samples. Furthermore, the signal-to-noise ratios obtained for these incompletely ionized elements in the argon ICP were further enhanced by a factor of four by continously introducing carbon as methanol via the mobile phase into the ICP. Sources of error in the HPLC system (column overload), in the sample introduction system (memory by organic solvents) and in the ICP-MS (spectroscopic interferences) and their prevention are also discussed. The optimized anion and cation exchange HPLC-ICP-MS systems were used for arsenic speciation in contaminated ground water and in an in-house shrimp reference sample. For the purpose of verification, HPLC coupled with tandem mass spectrometry with electrospray ionization was additionally used for arsenic speciation in the shrimp sample. With this analytical technique the HPLC retention time in combination with mass analysis of the molecular ions and their collision-induced fragments provide almost conclusive evidence of the identity of the analyte species. The speciation methods are validated by establishing a mass balance of the analytes in each fraction of the extraction procedure, by recovery of spikes and by employing and comparing independent techniques. The urgent need for reference materials certified for elemental species is stressed.
USDA-ARS?s Scientific Manuscript database
The USDA-ARS North Central Regional Plant Introduction Station in Ames, Iowa maintains an extensive working collection of Spinacia germplasm, both of cultivated and wild types, as part of the US National Plant Germplasm System. We seek to expand these collections by acquiring samples of allied gene...
Nathan, Lucas R; Jerde, Christopher L; Budny, Michelle L; Mahon, Andrew R
2015-04-01
Over 180 non-native species have been introduced in the Laurentian Great Lakes region, many posing threats to native species and ecosystem functioning. One potential pathway for introductions is the commercial bait trade; unknowing or unconcerned anglers commonly release unused bait into aquatic systems. Previous surveillance efforts of this pathway relied on visual inspection of bait stocks in retail shops, which can be time and cost prohibitive and requires a trained individual that can rapidly and accurately identify cryptic species. Environmental DNA (eDNA) surveillance, a molecular tool that has been used for surveillance in aquatic environments, can be used to efficiently detect species at low abundances. We collected and analyzed 576 eDNA samples from 525 retail bait shops throughout the Laurentian Great Lake states. We used eDNA techniques to screen samples for multiple aquatic invasive species (AIS) that could be transported in the bait trade, including bighead (Hypophthalmichthys nobilis) and silver carp (H. molitrix), round goby (Neogobius melanostomus), tubenose goby (Proterorhinus marmoratus), Eurasian rudd (Scardinius erythrophthalmus), and goldfish (Carassius auratus). Twenty-seven samples were positive for at least one target species (4.7% of samples), and all target species were found at least once, except bighead carp. Despite current regulations, the bait trade remains a potential pathway for invasive species introductions in the Great Lakes region. Alterations to existing management strategies regarding the collection, transportation, and use of live bait are warranted, including new and updated regulations, to prevent future introductions of invasive species in the Great Lakes via the bait trade. © 2014 Society for Conservation Biology.
[Design and evaluation of DAVIH VIH-2].
Martín Alfonso, Dayamí; Silva Cabrera, Eladio; Pérez Guevara, María T; Díaz Herrera, Dervel F; Romero Martínez, Kenia; Díaz Torres, Héctor M; Lubián Caballero, Ana L; Ruiz Gutiérrez, Nancy; Ortiz Losada, Eva
2007-01-01
The results of the design and evaluation of DAVIH VIH-2 diagnosing system, an indirect Elisa for screening of HIV-2 antibodies, which uses a HIV-2 glycoprotein gp36 synthetic peptide in its solid phase, were exposed. In the system evaluation using WHO reference panels, 100% sensitivity, 99,81% specificity, 99,81% efficacy and very good concordance level (kappa = 0.978) were attained. Serum samples of 959 individuals with undetermined or negative results to the HIV-1 antibodies confirmation (DAVIH blot) were evaluated by the DAVIH VIH-2 system. Twenty four samples were reactive, six of which had confirmed HIV-2 antibodies. These results allowed recommending the introduction of this diagnostic kit in the HIV infection diagnosing algorithm in Cuba.
Gregory, William D.; Capots, Larry H.; George, James P.; Janik, Richard
1981-01-01
The type of conductor, its property, and if a metal, its type and cross-sectional area can be obtained from measurements made at different frequencies for the amount of unbalance created in a previously balanced stable coil detection system. The true resistive component is accurately measured and thus reflects only the voltage loss attributable to eddy currents caused by introduction of the test sample to the coil system. This voltage divided by corresponding applied frequency gives a curve which peaks at a frequency dependent upon type of conductor. For a metal this peak frequency is proportional to the samples resistivity divided by its cross-sectional area.
Riessen, Reimer; Behmenburg, Melanie; Blumenstock, Gunnar; Guenon, Doris; Enkel, Sigrid; Schäfer, Richard; Haap, Michael
2015-01-01
Introduction Aim of this study was to reduce blood loss caused by diagnostic blood sampling and to minimize the development of anemia in a high-risk group of mechanically ventilated medical intensive care patients. We therefore implemented a “blood-saving bundle” (BSB) combining a closed-loop arterial blood sampling system, smaller sampling tubes, reduced frequency of blood drawings, and reduced sample numbers. Methods The study included all patients from our medical ICU who were ventilated for more than 72 hours. Exclusion criteria were: acute or chronic anemia on admission, bleeding episode(s) during the ICU stay, or end-of-life therapy. The BSB was introduced in 2009 with training and educational support. Patients treated in 2008, before the introduction of the BSB, served as a control group (n = 41, 617 observation days), and were compared with patients treated in 2010 after the introduction of the BSB (BSB group, n = 50, 559 observation days). Primary endpoints were blood loss per day, and development of anemia. Secondary endpoints were numbers of blood transfusions, number of days on mechanical ventilation, and length of the ICU stay. Results Mean blood loss per ICU day was decreased from 43.3 ml (95% CI: 41.2 to 45.3 ml) in the controls to 15.0 ml (14.3 to 15.7 ml) in the BSB group (P < 0.001). The introduction of a closed-loop arterial blood sampling system was the major contributor to this effect. Mean hemoglobin concentrations showed no significant differences in both groups during the ICU stay. Hemoglobin values <9 g/dl, however, were recorded in 21.2% of observation days in the controls versus 15.4% in the BSB group (P = 0.01). Units of transfused red blood cells per 100 observation days decreased from 7 to 2.3 (P < 0.001). The mean number of ventilation days was 7.1 days (6.1 to 8.3 days) in the controls and 7.5 days (6.6 to 8.5 days) in the BSB group (P = NS). In total, patients in the BSB group stayed in ICU for a mean of 9.9 days (8.6 to 11.3 days), compared to a mean ICU stay of 13.0 days (10.9 to 15.4 days) in the control group (P = 0.014). Due to the longitudinal study design, however, we cannot exclude uncontrolled confounders affecting the transfusion frequency and mean ICU stay. Conclusion Our BSB could be easily implemented and was able to reduce diagnostic blood loss. PMID:26421920
de Gois, Jefferson S; Vallelonga, Paul; Spolaor, Andrea; Devulder, Veerle; Borges, Daniel L G; Vanhaecke, Frank
2016-01-01
A simple and accurate methodology for Br isotope ratio measurements in seawater by multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) with pneumatic nebulization for sample introduction was developed. The Br(+) signals could be measured interference-free at high mass resolution. Memory effects for Br were counteracted using 5 mmol L(-1) of NH4OH in sample, standard, and wash solutions. The major cation load of seawater was removed via cation exchange chromatography using Dowex 50WX8 resin. Subsequent Br preconcentration was accomplished via evaporation of the sample solution at 90 °C, which did not induce Br losses or isotope fractionation. Mass discrimination was corrected for by external correction using a Cl-matched standard measured in a sample-standard bracketing approach, although Sr, Ge, and Se were also tested as potential internal standards for internal correction for mass discrimination. The δ(81)Br (versus standard mean ocean bromide (SMOB)) values thus obtained for the NaBr isotopic reference material NIST SRM 977 and for IRMM BCR-403 seawater certified reference material are in agreement with literature values. For NIST SRM 977, the (81)Br/(79)Br ratio (0.97291) was determined with a precision ≤0.08‰ relative standard deviation (RSD).
A Foundation for Systems Anthropometry.
1980-12-31
List of Tables Table Page 1 Screw Axis Analysis for Hip Motion 12 2 Screw Axis Analysis for Sacroiliac Motion 12 S, 1.0 Introduction The application...Following are two examples: 1) a sample of living subjects seated in a hard-seat and 2) the hip and sacroiliac kinematics of one unembalmed cadaver. In...axes for relative motion at the hip and sacroiliac joints. Each of the three bones was targeted with three pointmarks and an axis system calculated
The Effect of a Low Fluoride Delivery System on Bacterial Metabolism.
1981-08-25
of motile to non-motile bacteria in subgingival plaque samples is approximately 1:50; whereas in periodontally diseased sites, the ratio is approxi...parameters are indicated to assess the feasibility of this system as an adjunct in the control of caries and periodontal disease . 32 Antiplaque Determinants...of SnF2: pH and Ions INTRODUCTION The pathology of dental caries and periodontal disease is associated with the accumulation of bacterial plaque on
Sampling strategies exploiting multi-pumping flow systems.
Prior, João A V; Santos, João L M; Lima, José L F C
2003-04-01
In this work new strategies were exploited to implement multi-pumping flow systems relying on the utilisation of multiple devices that act simultaneously as sample-insertion, reagent-introduction, and solution-propelling units. The solenoid micro-pumps that were initially used as the only active elements of multi-pumping systems, and which were able to produce pulses of 3 to 25 microL, were replaced by syringe pumps with the aim of producing pulses between 1 and 4 microL. The performance of the developed flow system was assessed by using distinct sample-insertion strategies like single sample volume, merging zones, and binary sampling in the spectrophotometric determination of isoniazid in pharmaceutical formulations upon reaction with 1,2-naphthoquinone-4-sulfonate, in alkaline medium. The results obtained showed that enhanced sample/reagent mixing could be obtained with binary sampling and by using a 1 microL per step pump, even in limited dispersion conditions. Moreover, syringe pumps produce very reproducible flowing streams and are easily manipulated and controlled by a computer program, which is greatly simplified since they are the only active manifold component. Linear calibration plots up to 18.0 microg mL(-1), with a relative standard deviation of less than 1.48% (n=10) and a throughput of about 20 samples per hour, were obtained.
Identification and Quantitative Measurements of Chemical Species by Mass Spectrometry
NASA Technical Reports Server (NTRS)
Zondlo, Mark A.; Bomse, David S.
2005-01-01
The development of a miniature gas chromatograph/mass spectrometer system for the measurement of chemical species of interest to combustion is described. The completed system is a fully-contained, automated instrument consisting of a sampling inlet, a small-scale gas chromatograph, a miniature, quadrupole mass spectrometer, vacuum pumps, and software. A pair of computer-driven valves controls the gas sampling and introduction to the chromatographic column. The column has a stainless steel exterior and a silica interior, and contains an adsorbent of that is used to separate organic species. The detection system is based on a quadrupole mass spectrometer consisting of a micropole array, electrometer, and a computer interface. The vacuum system has two miniature pumps to maintain the low pressure needed for the mass spectrometer. A laptop computer uses custom software to control the entire system and collect the data. In a laboratory demonstration, the system separated calibration mixtures containing 1000 ppm of alkanes and alkenes.
Seltzer, Michael D
2003-09-01
Laser ablation of pressed soil pellets was examined as a means of direct sample introduction to enable inductively coupled plasma mass spectrometry (ICP-MS) screening of soils for residual depleted uranium (DU) contamination. Differentiation between depleted uranium, an anthropogenic contaminant, and naturally occurring uranium was accomplished on the basis of measured 235U/238U isotope ratios. The amount of sample preparation required for laser ablation is considerably less than that typically required for aqueous sample introduction. The amount of hazardous laboratory waste generated is diminished accordingly. During the present investigation, 235U/238U isotope ratios measured for field samples were in good agreement with those derived from gamma spectrometry measurements. However, substantial compensation was required to mitigate the effects of impaired pulse counting attributed to sample inhomogeneity and sporadic introduction of uranium analyte into the plasma.
Spatial and Temporal Analysis of Populations of the Sudden Oak Death Pathogen in Oregon Forests.
Kamvar, Z N; Larsen, M M; Kanaskie, A M; Hansen, E M; Grünwald, N J
2015-07-01
Sudden oak death caused by the oomycete Phytophthora ramorum was first discovered in California toward the end of the 20th century and subsequently emerged on tanoak forests in Oregon before its first detection in 2001 by aerial surveys. The Oregon Department of Forestry has since monitored the epidemic and sampled symptomatic tanoak trees from 2001 to the present. Populations sampled over this period were genotyped using microsatellites and studied to infer the population genetic history. To date, only the NA1 clonal lineage is established in this region, although three lineages exist on the North American west coast. The original introduction into the Joe Hall area eventually spread to several regions: mostly north but also east and southwest. A new introduction into Hunter Creek appears to correspond to a second introduction not clustering with the early introduction. Our data are best explained by both introductions originating from nursery populations in California or Oregon and resulting from two distinct introduction events. Continued vigilance and eradication of nursery populations of P. ramorum are important to avoid further emergence and potential introduction of other clonal lineages.
Integrated Reconfigurable Intelligent Systems (IRIS) for Complex Naval Systems
2011-02-23
INTRODUCTION 35 2.2 GENERAL MODEL SETUP 36 2.2.1 Co-Simulation Principles 36 2.2.2 Double pendulum : a simple example 38 2.2.3 Description of numerical... pendulum sample problem 45 2.3 DISCUSSION OF APPROACH WITH RESPECT TO PROPOSED SUBTASKS 49 2.4 RESULTS DISCUSSION AND FUTURE WORK 49 TASK 3...Kim and Praehofer 2000]. 2.2.2 Double pendulum : a simple example In order to be able to evaluate co-simulation principles, specifically an
From inverse problems to learning: a Statistical Mechanics approach
NASA Astrophysics Data System (ADS)
Baldassi, Carlo; Gerace, Federica; Saglietti, Luca; Zecchina, Riccardo
2018-01-01
We present a brief introduction to the statistical mechanics approaches for the study of inverse problems in data science. We then provide concrete new results on inferring couplings from sampled configurations in systems characterized by an extensive number of stable attractors in the low temperature regime. We also show how these result are connected to the problem of learning with realistic weak signals in computational neuroscience. Our techniques and algorithms rely on advanced mean-field methods developed in the context of disordered systems.
Sample Handling and Chemical Kinetics in an Acoustically Levitated Drop Microreactor
2009-01-01
Accurate measurement of enzyme kinetics is an essential part of understanding the mechanisms of biochemical reactions. The typical means of studying such systems use stirred cuvettes, stopped-flow apparatus, microfluidic systems, or other small sample containers. These methods may prove to be problematic if reactants or products adsorb to or react with the container’s surface. As an alternative approach, we have developed an acoustically-levitated drop reactor eventually intended to study enzyme-catalyzed reaction kinetics related to free radical and oxidative stress chemistry. Microliter-scale droplet generation, reactant introduction, maintenance, and fluid removal are all important aspects in conducting reactions in a levitated drop. A three capillary bundle system has been developed to address these needs. We report kinetic measurements for both luminol chemiluminescence and the reaction of pyruvate with nicotinamide adenine dinucleotide, catalyzed by lactate dehydrogenase, to demonstrate the feasibility of using a levitated drop in conjunction with the developed capillary sample handling system as a microreactor. PMID:19769373
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eiden, Gregory C.; Duffin, Andrew M.; Liezers, Martin
2014-11-14
Recently, a new class of multi-collector inductively coupled plasma mass spectrometers (MC-ICPMS) has been introduced commercially that includes detector arrays purpose built for actinide measurements. These detector arrays significantly enhance the data quality possible for applications encountered in nuclear forensics. Two such instruments are described in this paper, the NeptunePlusTM, developed by Thermo-Fisher (Bremen, Germany), and the NuPlasma2, developed by Nu Instruments (Wrexham, UK). Research results are presented that have been obtained by the authors using the first commercial NeptunePlusTM. This paper also presents performance characteristics and results for traditional liquid introduction, including a means for ultra-trace detection via electrochemicalmore » separation prior to solution nebulization, as well as solid sample introduction with femtosecond-laser ablation. We also discuss the advantages and limitations of the current systems for detection of the transient signals associated with these two methods for introducing sample into the plasma.« less
Murphy, Karen E; Vetter, Thomas W
2013-05-01
The potential effect of spectral interference on the accurate measurement of the cadmium (Cd) mass fraction in fortified breakfast cereal and a variety of dietary supplement materials using inductively coupled plasma quadrupole mass spectrometry was studied. The materials were two new standard reference materials (SRMs)--SRM 3233 Fortified Breakfast Cereal and SRM 3532 Calcium Dietary Supplement--as well as several existing materials--SRM 3258 Bitter Orange Fruit, SRM 3259 Bitter Orange Extract, SRM 3260 Bitter Orange-containing Solid Oral Dosage Form, and SRM 3280 Multivitamin/Multielement Tablets. Samples were prepared for analysis using the method of isotope dilution and measured using various operating and sample introduction configurations including standard mode, collision cell with kinetic energy discrimination mode, and standard mode with sample introduction via a desolvating nebulizer system. Three isotope pairs, (112)Cd/(111)Cd, (113)Cd/(111)Cd, and (114)Cd/(111)Cd, were measured. Cadmium mass fraction results for the unseparated samples of each material, measured using the three instrument configurations and isotope pairs, were compared to the results obtained after the matrix was removed via chemical separation using anion exchange chromatography. In four of the six materials studied, measurements using the standard mode with sample introduction via the desolvating nebulizer gave results for the unseparated samples quantified with the (112)Cd/(111)Cd isotope pair that showed a positive bias relative to the matrix-separated samples, which indicated a persistent inference at m/z112 with this configuration. Use of the standard mode, without the desolvating nebulizer, also gave results that showed a positive bias for the unseparated samples quantified with the (112)Cd/(111)Cd isotope pair in three of the materials studied. Collision cell/kinetic energy discrimination mode, however, was very effective for reducing spectral interference for Cd in all of the materials and isotope pairs studied, except in the multivitamin/multielement matrix (SRM 3280) where the large corrections for known isobaric interferences or unidentified interferences compromised the accuracy. For SRM 3280, matrix separation provided the best method to achieve accurate measurement of Cd.
Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?
Phelan, Michael P.; Reineks, Edmunds Z.; Hustey, Fredric M.; Berriochoa, Jacob P.; Podolsky, Seth R.; Meldon, Stephen; Schold, Jesse D.; Chamberlin, Janelle; Procop, Gary W.
2016-01-01
Introduction Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. Methods The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest®) for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. Results During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]). Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99]) or mild (10.3% vs 9.8% [p=0.88]) hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%–14.6%). Conclusion We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material). Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department. PMID:27625719
Evelyn S. Wenk; Mac A. Callaham; Joseph O' Brien; Paul J. Hanson
2016-01-01
Within the temperate, deciduous forests of the eastern US, diverse soil-fauna communities are structured by a combination of environmental gradients and interactions with other biota. The introduction of non-native soil taxa has altered communities and soil processes, and adds another degree of variability to these systems. We sampled soil macroinvertebrate abundance...
Rubidium distribution at atomic scale in high efficient Cu(In,Ga)Se2 thin-film solar cells
NASA Astrophysics Data System (ADS)
Vilalta-Clemente, Arantxa; Raghuwanshi, Mohit; Duguay, Sébastien; Castro, Celia; Cadel, Emmanuel; Pareige, Philippe; Jackson, Philip; Wuerz, Roland; Hariskos, Dimitrios; Witte, Wolfram
2018-03-01
The introduction of a rubidium fluoride post deposition treatment (RbF-PDT) for Cu(In,Ga)Se2 (CIGS) absorber layers has led to a record efficiency up to 22.6% for thin-film solar cell technology. In the present work, high efficiency CIGS samples with RbF-PDT have been investigated by atom probe tomography (APT) to reveal the atomic distribution of all alkali elements present in CIGS layers and compared with non-treated samples. A Scanning Electron Microscopy Dual beam station (Focused Ion Beam-Gas Injection System) as well as Transmission Kikuchi diffraction is used for atom probe sample preparation and localization of the grain boundaries (GBs) in the area of interest. The analysis of the 3D atomic scale APT reconstructions of CIGS samples with RbF-PDT shows that inside grains, Rb is under the detection limit, but the Na concentration is enhanced as compared to the reference sample without Rb. At the GBs, a high concentration of Rb reaching 1.5 at. % was found, and Na and K (diffusing from the glass substrate) are also segregated at GBs but at lower concentrations as compared to Rb. The intentional introduction of Rb leads to significant changes in the chemical composition of CIGS matrix and at GBs, which might contribute to improve device efficiency.
Planetary Protection Technologies: Technical Challenges for Mars Exploration
NASA Technical Reports Server (NTRS)
Buxbaum, Karen L.
2005-01-01
The search for life in the solar system, using either in situ analysis or sample return, brings with it special technical challenges in the area of planetary protection. Planetary protection (PP) requires planetary explorers to preserve biological and organic conditions for future exploration and to protect the Earth from potential extraterrestrial contamination that could occur as a result of sample return to the Earth-Moon system. In view of the exploration plans before us, the NASA Solar System Exploration Program Roadmap published in May 2003 identified planetary protection as one of 13 technologies for "high priority technology investments." Recent discoveries at Mars and Jupiter, coupled with new policies, have made this planning for planetary protection technology particularly challenging and relevant.New missions to Mars have been formulated, which present significantly greater forward contamination potential. New policies, including the introduction by COSPAR of a Category IVc for planetary protection, have been adopted by COSPAR in response. Some missions may not be feasible without the introduction of new planetary protection technologies. Other missions may be technically possible but planetary protection requirements may be so costly to implement with current technology that they are not affordable. A strategic investment strategy will be needed to focus on technology investments designed to enable future missions and reduce the costs of future missions. This presentation will describe some of the potential technological pathways that may be most protective.
Warrant Officer Orientation Course (WOOC) Evaluation
1981-10-01
Army Mainte- nance Management System, Security Awareness, Organizational Effectiveness, Introduction to Management , Enlisted Personnel Management...Orientation Introduction to Management Professional Ethics USA Officer Evaluation Reporting System (OES) Military Correspondence Military...Organizational Effectiveness, Introduction to Management , Enlisted Personnal Management System, and The Army Functional Files System and The Army
Flow-based analysis using microfluidics-chemiluminescence systems.
Al Lawati, Haider A J
2013-01-01
This review will discuss various approaches and techniques in which analysis using microfluidics-chemiluminescence systems (MF-CL) has been reported. A variety of applications is examined, including environmental, pharmaceutical, biological, food and herbal analysis. Reported uses of CL reagents, sample introduction techniques, sample pretreatment methods, CL signal enhancement and detection systems are discussed. A hydrodynamic pumping system is predominately used for these applications. However, several reports are available in which electro-osmotic (EO) pumping has been implemented. Various sample pretreatment methods have been used, including liquid-liquid extraction, solid-phase extraction and molecularly imprinted polymers. A wide range of innovative techniques has been reported for CL signal enhancement. Most of these techniques are based on enhancement of the mixing process in the microfluidics channels, which leads to enhancement of the CL signal. However, other techniques are also reported, such as mirror reaction, liquid core waveguide, on-line pre-derivatization and the use of an opaque white chip with a thin transparent seal. Photodetectors are the most commonly used detectors; however, other detection systems have also been used, including integrated electrochemiluminescence (ECL) and organic photodiodes (OPDs). Copyright © 2012 John Wiley & Sons, Ltd.
Laser ablation in analytical chemistry - A review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Russo, Richard E.; Mao, Xianglei; Liu, Haichen
Laser ablation is becoming a dominant technology for direct solid sampling in analytical chemistry. Laser ablation refers to the process in which an intense burst of energy delivered by a short laser pulse is used to sample (remove a portion of) a material. The advantages of laser ablation chemical analysis include direct characterization of solids, no chemical procedures for dissolution, reduced risk of contamination or sample loss, analysis of very small samples not separable for solution analysis, and determination of spatial distributions of elemental composition. This review describes recent research to understand and utilize laser ablation for direct solid sampling,more » with emphasis on sample introduction to an inductively coupled plasma (ICP). Current research related to contemporary experimental systems, calibration and optimization, and fractionation is discussed, with a summary of applications in several areas.« less
Development of a large color range for a paint company
NASA Astrophysics Data System (ADS)
McGinley, Peter
2002-06-01
Experience with the Master Palette system of 6000 colors lead to a specification for a new color range where the primary design feature is the control of the paint tint formula. This design approach met a market-derived requirement for sample pots and fractional-strength colors. The layout process employed was able to display the color capability of the paint system and generate an array of colors with controlled spacing similar to Master Palette. Updated pigment selections and the introduction of additional colored bases completed the system specification of improved opacity and every color being exterior durable.
Flux pinning by precipitates in the Bi-Sr-Ca-Cu-O system
Shi, Donglu
1992-01-01
A fundamental pinning mechanism has been identified in the Bi-Sr-Ca-Cu-O system. The pinning strength has been greatly increased by the introduction of calcium- and copper-rich precipitates into the sample matrix. The calcium and copper are supersaturated in the system by complete melting, and the fine calcium and copper particles precipitated during subsequent crystallization anneal to obtain the superconducting phases. The intragrain critical current density has been increased from the order of 10.sup.5 A/cm.sup.2 to 10.sup.7 A/cm.sup.2 at 5 T.
LaFleur, Alesha D; Schug, Kevin A
2011-06-24
Recent methods of separation and detection for the quantification of trace-level concentrations of selected endocrine disrupting compounds (EDCs) from aqueous systems are reviewed. A brief introduction of the selected EDCs (natural and synthetic estrogens and plastics-derived xenoestrogens), including their characteristics and importance, is presented. Sample preparation and extraction trends are discussed. Various types of separation techniques are presented, with the express goal of emphasizing time and cost-effective methods that isolate and quantify trace-levels of multiple endocrine disruptors from aqueous systems. Copyright © 2011 Elsevier B.V. All rights reserved.
Dupuis, S; Fecci, J-L; Noyer, P; Lecarpentier, E; Chollet-Xémard, C; Margenet, A; Marty, J; Combes, X
2009-01-01
To assess economical impact after introduction of a bar coding pharmacy stock replenishment system in a prehospital emergency medical unit. Observational before and after study. A computer system using specific software and bare-code technology was introduced in the pre hospital emergency medical unit (Smur). Overall activity and costs related to pharmacy were recorded annually during two periods: the first 2 years period before computer system introduction and the second one during the 4 years following this system installation. The overall clinical activity increased by 10% between the two periods whereas pharmacy related costs continuously decreased after the start of pharmacy management computer system use. Pharmacy stock management was easier after introduction of the new stock replenishment system. The mean pharmacy related cost of one patient management was 13 Euros before and 9 Euros after the introduction of the system. The overall cost savings during the studied period was calculated to reach 134,000 Euros. The introduction of a specific pharmacy management computer system allowed to do important costs savings in a prehospital emergency medical unit.
Synthesis of carbon nanofibers by catalytic CVD of chlorobenzene over bulk nickel alloy
NASA Astrophysics Data System (ADS)
Kenzhin, Roman M.; Bauman, Yuri I.; Volodin, Alexander M.; Mishakov, Ilya V.; Vedyagin, Aleksey A.
2018-01-01
Catalytic chemical vapor deposition (CCVD) of chlorobenzene over bulk nickel alloy (nichrome) was studied. The bulk Ni-containing samples being exposed to a contact with aggressive reaction medium undergo self-disintegration followed by growth of carbon nanofibers. This process, also known as a metal dusting, requires the simultaneous presence of chlorine and hydrogen sources in the reaction mixture. Molecule of chlorobenzene complies with these requirements. The experiments on CCVD were performed in a flow-through reactor system. The initial stages of nickel disintegration process were investigated in a closed system under Autogenic Pressure at Elevated Temperature (RAPET) conditions. Scanning and transmission electron microscopies and ferromagnetic resonance spectroscopy were applied to examine the samples after their interaction with chlorobenzene. Introduction of additional hydrogen into the flow-through system was shown to affect the morphology of grown carbon nanofibers.
Hammam, H M; Allam, F A; Hassanein, F; El-Garby, M T
1975-01-01
Four villages in Assiut Governorate were studied. They were matched for availability and time of introduction of medical services, the size of population and the socioeconomic status. One village had a basin system of irrigation. The other three villages had perennial irrigation introduced at different dates. A sketch map of each village was made showing the location of every house and the irrigation channels. Total coverage was intended in Gezirat El-Maabda (with basin irrigation) and Nazza Karar (with perennial irrigation-recently introduced). In El-Ghorayeb and Garf Sarhan (with older systems of perennial irrigation) systematic random samples were studied. The Study included a full, double check clinical examination of urine and stools samples and a social study. Data about educational level and activities that bring the individual in contact with canal water were recorded. Tables showing the age and sex distribution of the total population and the population studied in each village are presented and show validity of the samples taken from the population.
Modified electrokinetic sample injection method in chromatography and electrophoresis analysis
Davidson, J. Courtney; Balch, Joseph W.
2001-01-01
A sample injection method for horizontal configured multiple chromatography or electrophoresis units, each containing a number of separation/analysis channels, that enables efficient introduction of analyte samples. This method for loading when taken in conjunction with horizontal microchannels allows much reduced sample volumes and a means of sample stacking to greatly reduce the concentration of the sample. This reduction in the amount of sample can lead to great cost savings in sample preparation, particularly in massively parallel applications such as DNA sequencing. The essence of this method is in preparation of the input of the separation channel, the physical sample introduction, and subsequent removal of excess material. By this method, sample volumes of 100 nanoliter to 2 microliters have been used successfully, compared to the typical 5 microliters of sample required by the prior separation/analysis method.
1990-07-01
permeation chromatography (GPC) have been applied to lubricant type samples. 8 Most recently the newly introduced supercritical fluid chromatography (SFC... fluids , such as lubricants and hydraulic fluids can also be examined using various inverse chromatography procedures. Another mode, known as reaction...introduction of new gaseous extraction techniques, e.g., supercritical fluid extraction, procedures such as IGC will probably be developed for vastly
ERIC Educational Resources Information Center
Beaudin, Michel; Picard, Gilles
2010-01-01
Starting in September 1999, new students at ETS were required to own the TI-92 Plus or TI-89 symbolic calculator and since September 2002, the Voyage 200. Looking back at these ten years of working with a computer algebra system on every student's desk, one could ask whether the introduction of this hand-held technology has really forced teachers…
2007-11-15
Intelligence and Information Systems (IIS) Enterprise CMMI® ML3 SCAMPI(SM) SE/SW/IPPD/SS #5382 Raymond L. Kile , SEI Authorized Lead Appraiser Kathryn...Kirby, Raytheon IIS Process Assessments IPT Lead Picking a Representative Sample For CMMI® Enterprise Appraisals Page 2 Introductions Ray Kile has thirty...University of Missouri. Raymond L. Kile Chief Engineer Center for Systems Management 1951 Kidwell Drive, Suite 750 Vienna, VA 22182 303-601-8978 rkile@csm.com
Analytical aspects of plant metabolite profiling platforms: current standings and future aims.
Seger, Christoph; Sturm, Sonja
2007-02-01
Over the past years, metabolic profiling has been established as a comprehensive systems biology tool. Mass spectrometry or NMR spectroscopy-based technology platforms combined with unsupervised or supervised multivariate statistical methodologies allow a deep insight into the complex metabolite patterns of plant-derived samples. Within this review, we provide a thorough introduction to the analytical hard- and software requirements of metabolic profiling platforms. Methodological limitations are addressed, and the metabolic profiling workflow is exemplified by summarizing recent applications ranging from model systems to more applied topics.
NASA Technical Reports Server (NTRS)
Ashwal, Lewis D.; Wooden, Joseph L.
1989-01-01
This paper presents Nd, Sr, and Pb isotopic data indicating a late-Archean/early-Proterozoic age for the River Valley anorthositic pluton of the southwestern Grenville Province of Sudbury, Ontario. Pb-Pb isotopic data on 10 whole-rock samples ranging in composition from anorthosite to gabbro yield an age of 2560 + or - 155 Ma. The River Valley pluton is thus the oldest anorthositic intrusive yet recognized within the Grenville Province. The Sm-Nd isotopic system records an age of 2377 + or - 68 Ma. High Pb-208/Pb-204 of deformed samples relative to igneous-textured rocks implies Th introduction and/or U loss during metamorphism in the River Valley area. Rb-Sr data from igneous-textured and deformed samples and from mineral separates give an age of 2185 + or - 105 Ma, indicating substantial disturbance of the Rb-Sr isotopic system.
An introduction to the Marshall information retrieval and display system
NASA Technical Reports Server (NTRS)
1974-01-01
An on-line terminal oriented data storage and retrieval system is presented which allows a user to extract and process information from stored data bases. The use of on-line terminals for extracting and displaying data from the data bases provides a fast and responsive method for obtaining needed information. The system consists of general purpose computer programs that provide the overall capabilities of the total system. The system can process any number of data files via a Dictionary (one for each file) which describes the data format to the system. New files may be added to the system at any time, and reprogramming is not required. Illustrations of the system are shown, and sample inquiries and responses are given.
Ten years of preanalytical monitoring and control: Synthetic Balanced Score Card Indicator
López-Garrigós, Maite; Flores, Emilio; Santo-Quiles, Ana; Gutierrez, Mercedes; Lugo, Javier; Lillo, Rosa; Leiva-Salinas, Carlos
2015-01-01
Introduction Preanalytical control and monitoring continue to be an important issue for clinical laboratory professionals. The aim of the study was to evaluate a monitoring system of preanalytical errors regarding not suitable samples for analysis, based on different indicators; to compare such indicators in different phlebotomy centres; and finally to evaluate a single synthetic preanalytical indicator that may be included in the balanced scorecard management system (BSC). Materials and methods We collected individual and global preanalytical errors in haematology, coagulation, chemistry, and urine samples analysis. We also analyzed a synthetic indicator that represents the sum of all types of preanalytical errors, expressed in a sigma level. We studied the evolution of those indicators over time and compared indicator results by way of the comparison of proportions and Chi-square. Results There was a decrease in the number of errors along the years (P < 0.001). This pattern was confirmed in primary care patients, inpatients and outpatients. In blood samples, fewer errors occurred in outpatients, followed by inpatients. Conclusion We present a practical and effective methodology to monitor unsuitable sample preanalytical errors. The synthetic indicator results summarize overall preanalytical sample errors, and can be used as part of BSC management system. PMID:25672466
A method for introduction of Al2O3 nanofiber into aluminum alloy
NASA Astrophysics Data System (ADS)
Chen, Yijin; Qin, He; Kurganova, Y. A.; Gaaze, V. K.
2018-04-01
Experimental samples of aluminum matrix composites (AMCs) reinforced with Al2O3 nanofibers were obtained. In order to increase the wettability in liquid phase combination conditions, it is proposed to use copper powder as a carrier of nanofiber. When studying the structure of the samples, a modifying effect of the introduction of reinforcement, demonstrated by grinding the grain, was revealed.
NASA Technical Reports Server (NTRS)
Merritt, Dawn A.; Hayes, J. M.; Des Marais, David J.
1995-01-01
Less than 15 min are required for the determination of delta C(sub PDB)-13 with a precision of 0.2 ppt(1 sigma, single measurement) in 5-mL samples of air containing CH4 at natural levels (1.7 ppm). An analytical system including a sample-introduction unit incorporating a preparative gas chromatograph (GC) column for separation of CH4 from N2, O2, and Ar is described. The 15-min procedure includes time for operation of that system, high-resolution chromatographic separation of the CH4, on-line combustion and purification of the products, and isotopic calibration. Analyses of standards demonstrate that systematic errors are absent and that there is no dependence of observed values of delta on sample size. For samples containing 100 ppm or more CH4, preconcentration is not required and the analysis time is less than 5 min. The system utilizes a commercially available, high-sensitivity isotope-ratio mass spectrometer. For optimal conditions of smaple handling and combustion, performance of the system is within a factor of 2 of the shot-noise limit. The potential exists therefore for analysis of samples as small as 15 pmol CH4 with a standard deviation of less than 1 ppt.
Ranjbar, Mansour; Shoghli, Alireza; Kolifarhood, Goodarz; Tabatabaei, Seyed Mehdi; Amlashi, Morteza; Mohammadi, Mahdi
2016-03-02
Malaria re-introduction is a challenge in elimination settings. To prevent re-introduction, receptivity, vulnerability, and health system capacity of foci should be monitored using appropriate tools. This study aimed to design an applicable model to monitor predicting factors of re-introduction of malaria in highly prone areas. This exploratory, descriptive study was conducted in a pre-elimination setting with a high-risk of malaria transmission re-introduction. By using nominal group technique and literature review, a list of predicting indicators for malaria re-introduction and outbreak was defined. Accordingly, a checklist was developed and completed in the field for foci affected by re-introduction and for cleared-up foci as a control group, for a period of 12 weeks before re-introduction and for the same period in the previous year. Using field data and analytic hierarchical process (AHP), each variable and its sub-categories were weighted, and by calculating geometric means for each sub-category, score of corresponding cells of interaction matrices, lower and upper threshold of different risks strata, including low and mild risk of re-introduction and moderate and high risk of malaria outbreaks, were determined. The developed predictive model was calibrated through resampling with different sets of explanatory variables using R software. Sensitivity and specificity of the model were calculated based on new samples. Twenty explanatory predictive variables of malaria re-introduction were identified and a predictive model was developed. Unpermitted immigrants from endemic neighbouring countries were determined as a pivotal factor (AHP score: 0.181). Moreover, quality of population movement (0.114), following malaria transmission season (0.088), average daily minimum temperature in the previous 8 weeks (0.062), an outdoor resting shelter for vectors (0.045), and rainfall (0.042) were determined. Positive and negative predictive values of the model were 81.8 and 100 %, respectively. This study introduced a new, simple, yet reliable model to forecast malaria re-introduction and outbreaks eight weeks in advance in pre-elimination and elimination settings. The model incorporates comprehensive deterministic factors that can easily be measured in the field, thereby facilitating preventive measures.
14 CFR Section 1 - Introduction to System of Accounts and Reports
Code of Federal Regulations, 2010 CFR
2010-01-01
... AIR CARRIERS General Accounting Provisions Section 1 Introduction to System of Accounts and Reports ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Introduction to System of Accounts and Reports Section 1 Section 1 Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION...
NASA Astrophysics Data System (ADS)
Sibirmovsky, Y. D.; Vasil'evskii, I. S.; Vinichenko, A. N.; Zhigunov, D. M.; Eremin, I. S.; Kolentsova, O. S.; Safonov, D. A.; Kargin, N. I.
2017-11-01
Samples of δ-Si doped AlGaAs/GaAs/AlGaAs HEMT heterostructures with GaAs quantum rings (QRs) on top of the quantum well (QW) were grown by molecular beam epitaxy and their properties were compared to the reference samples without QRs. The thickness of the QW was 6 - 10 nm for the samples with QRs and 20 nm for the reference samples. Photoluminescence measurements at low temperatures for all samples show at least two distinct lines in addition to the bulk GaAs line. The Hall effect and low temperature magnetotransport measurements at 4 - 320 K show that conductivity with and without illumination decreases significantly with QRs introduction, however the relative photoconductivity increases. Samples with 6 nm QW are insulating, which could be caused by the strong localization of the charge carriers in the QRs.
Henttonen, H; Fuglei, E; Gower, C N; Haukisalmi, V; Ims, R A; Niemimaa, J; Yoccoz, N G
2001-12-01
The taeniid tapeworm Echinococcus multilocularis is here reported for the first time at the Svalbard Archipelago in the Norwegian Arctic. This new finding is interesting because the establishment of E. multilocularis is due to a recent anthropogenic introduction of its intermediate host--the sibling vole Microtus rossiaemeridionalis at Svalbard. The parasite itself has probably become naturally transferred to Svalbard due to migratory movements of its final host--the arctic fox Alopex lagopus between source areas for E. multilocularis in Siberia and Svalbard. We report macroscopically determined prevalence of E. multilocularis from a sample of 224 voles trapped in August in 1999 and 2000. The prevalence was among the highest ever recorded in intermediate hosts and was dependent on age and sex of the hosts approaching 100% in overwintered males. The high prevalence and the simplicity of the vole-arctic fox-E. multilocularis system at Svalbard makes it an eminent model system for further epidemiological studies.
Determinants of performance failure in the nursing home industry☆
Zinn, Jacqueline; Mor, Vincent; Feng, Zhanlian; Intrator, Orna
2013-01-01
This study investigates the determinants of performance failure in U.S. nursing homes. The sample consisted of 91,168 surveys from 10,901 facilities included in the Online Survey Certification and Reporting system from 1996 to 2005. Failed performance was defined as termination from the Medicare and Medicaid programs. Determinants of performance failure were identified as core structural change (ownership change), peripheral change (related diversification), prior financial and quality of care performance, size and environmental shock (Medicaid case mix reimbursement and prospective payment system introduction). Additional control variables that could contribute to the likelihood of performance failure were included in a cross-sectional time series generalized estimating equation logistic regression model. Our results support the contention, derived from structural inertia theory, that where in an organization’s structure change occurs determines whether it is adaptive or disruptive. In addition, while poor prior financial and quality performance and the introduction of case mix reimbursement increases the risk of failure, larger size is protective, decreasing the likelihood of performance failure. PMID:19128865
Determinants of performance failure in the nursing home industry.
Zinn, Jacqueline; Mor, Vincent; Feng, Zhanlian; Intrator, Orna
2009-03-01
This study investigates the determinants of performance failure in U.S. nursing homes. The sample consisted of 91,168 surveys from 10,901 facilities included in the Online Survey Certification and Reporting system from 1996 to 2005. Failed performance was defined as termination from the Medicare and Medicaid programs. Determinants of performance failure were identified as core structural change (ownership change), peripheral change (related diversification), prior financial and quality of care performance, size and environmental shock (Medicaid case mix reimbursement and prospective payment system introduction). Additional control variables that could contribute to the likelihood of performance failure were included in a cross-sectional time series generalized estimating equation logistic regression model. Our results support the contention, derived from structural inertia theory, that where in an organization's structure change occurs determines whether it is adaptive or disruptive. In addition, while poor prior financial and quality performance and the introduction of case mix reimbursement increases the risk of failure, larger size is protective, decreasing the likelihood of performance failure.
Shim, J H; Lee, Y S; Kim, M R; Lee, C J; Kim, I S
2003-10-10
We examined a Keele injector for sample introduction for gas chromatographic analysis of vinclozolin treated in lettuces. Samples in milligram quantity were introduced into a glass tube in a Keele injector at a gas chromatograph injection port. The glass tube was then crushed to allow the sample to carry onto a capillary column in a normal manner. The standard calibration curve for quantitative detection of vinclozolin was obtained by determining vinclozolin spiked in samples at variable concentrations. The calibration curve showed a linear response to vinclozolin ranging from 0.05 to 1.0 microg/g, giving a slope value of 174.8, the y-intercept value of -2.8146 and the mean r2-value of 0.9994. Limit of quantification for vinclozolin was 0.05 microg/g by this method, comparable to 0.01 microg/g by a normal injector. When samples treated previously with vinclozolin were determined by the Keele injector, vinclozolin was found to be about 30% lower as compared to a normal method, suggesting about 70% recovery of the spiked vinclozolin by the Keele injector. From these results, the Keele injector was suggested to be potential for sample introduction in gas chromatographic analysis of vinclozolin in lettuce samples.
1984-06-26
irred. 2’. 4’.. Nava Het esarch CenterU 0i P. 0. Bx 8512 San iego Caiforia 2138917 P. W. SUMMARY The Naval Occupational Health information Management System (WHIMS...Introduction and OHS Options I. INTRODUCTION TO THE NAVY OCCUPATIONAL HEALTH INFORMATION MANAGEMENT SYSTEM (NOHIMS) The objective of NOHIMS is to provide an
48 CFR 1846.670 - Introduction.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Introduction. 1846.670 Section 1846.670 Federal Acquisition Regulations System NATIONAL AERONAUTICS AND SPACE ADMINISTRATION CONTRACT MANAGEMENT QUALITY ASSURANCE Material Inspection and Receiving Reports 1846.670 Introduction. ...
Development of a High-Throughput Microwave Imaging System for Concealed Weapons Detection
2016-07-15
hardware. Index Terms—Microwave imaging, multistatic radar, Fast Fourier Transform (FFT). I. INTRODUCTION Near-field microwave imaging is a non-ionizing...configuration, but its computational demands are extreme. Fast Fourier Transform (FFT) imaging has long been used to efficiently construct images sampled with...Simulated image of 25 point scatterers imaged at range 1.5m, with array layout depicted in Fig. 3. Left: image formed with Equation (5) ( Fourier
Life-Cycle Cost Database. Volume II. Appendices E, F, and G. Sample Data Development.
1983-01-01
Bendix Field Engineering Corporation Columbia, Maryland 21045 5 CONTENTS Page GENERAL 8 Introduction Objective Engineering Survey SYSTEM DESCRIPTION...in a typical administrative type building over a 25-year period. 1.3 ENGINEERING SURVEY An on-site survey was conducted by Bendix Field Engineering...Damp Mop and Buff Buff Routine Vacuum Strip and Refinish Heavy Duty Vacuum Machine, Scrub and Surface Shampoo Pick Up Extraction Clean Repair Location
Model Checking the Remote Agent Planner
NASA Technical Reports Server (NTRS)
Khatib, Lina; Muscettola, Nicola; Havelund, Klaus; Norvig, Peter (Technical Monitor)
2001-01-01
This work tackles the problem of using Model Checking for the purpose of verifying the HSTS (Scheduling Testbed System) planning system. HSTS is the planner and scheduler of the remote agent autonomous control system deployed in Deep Space One (DS1). Model Checking allows for the verification of domain models as well as planning entries. We have chosen the real-time model checker UPPAAL for this work. We start by motivating our work in the introduction. Then we give a brief description of HSTS and UPPAAL. After that, we give a sketch for the mapping of HSTS models into UPPAAL and we present samples of plan model properties one may want to verify.
Lahariya, Chandrakant; Paruthi, Renu; Bhattacharya, Madhulekha
2016-04-01
To summarize the findings from a Post Introduction Evaluation (PIE) of pentavalent vaccine in Tamil Nadu and Kerala state of India and to understand how the health systems could be prepared for (prior to) introducing a new intervention and how such introduction could affect the health systems (afterwards). A post introduction evaluation (PIE) of Haemophilus influenzae type b (Hib) as pentavalent (DPT + HepB + Hib) vaccine was conducted in Tamil Nadu and Kerala states of India in July-Aug 2012. The PIE was conducted as per World Health Organization PIE methods and tools specifically adapted for India. This PIE adopted a 'mixed method approach' with qualitative data focus. The planning for the introduction of pentavalent vaccine provided opportunities to strengthen various functions of the health system i.e., piloting of Open Vial Policy, strengthening surveillance system, improving Adverse Events Following Immunization (AEFI) reporting system and formation of the technical expert groups. It provided opportunity for bringing attention on the immunization programme in general as well. After the vaccine introduction, the beneficial effects were noted on stewardship (increased oversight by top level policy makers and programme managers), creating resources (investment and trainings of staff in immunization), service delivery (increased coverage with the vaccines and improved quality of services) and financing (increased financial allocation and reduced out of pocket expenditures as more people started attending public health facilities). The vaccine introduction was found to be associated with improvement in the health equity, efficiency and service utilization (effective coverage). New vaccine introduction provides opportunities (both before and after) for strengthening the health systems in setting such as India. Preparing the health system for new challenges has potential to strengthen the health systems, if done in well-coordinated and planned manner. Considering that essential steps are largely similar, these lessons could be applicable for the introduction of other new health interventions in the similar settings.
Deuterium retention and surface modification of tungsten macrobrush samples exposed in FTU Tokamak
NASA Astrophysics Data System (ADS)
Maddaluno, G.; Giacomi, G.; Rufoloni, A.; Verdini, L.
2007-06-01
The effect of discrete structures such as macrobrush or castellated surfaces on power handling and deuterium retention of plasma facing components is to be assessed since such geometrical configurations are needed for increasing the lifetime of the armour to heat-sink joint. Four small macrobrush W and W + 1%La2O3 samples have been exposed in the Frascati Tokamak Upgrade (FTU) scrape-off layer up to the last closed flux surface by means of the Sample Introduction System. FTU is an all metal machine with no carbon source inside vacuum vessel; it exhibits ITER relevant energy and particle fluxes on the plasma facing components. Here, results on morphological surface changes (SEM), chemical composition (EDX) and deuterium retention (TDS) are reported.
Xu, Chun-Xiu; Yin, Xue-Feng
2011-02-04
A chip-based microfluidic system for high-throughput single-cell analysis is described. The system was integrated with continuous introduction of individual cells, rapid dynamic lysis, capillary electrophoretic (CE) separation and laser induced fluorescence (LIF) detection. A cross microfluidic chip with one sheath-flow channel located on each side of the sampling channel was designed. The labeled cells were hydrodynamically focused by sheath-flow streams and sequentially introduced into the cross section of the microchip under hydrostatic pressure generated by adjusting liquid levels in the reservoirs. Combined with the electric field applied on the separation channel, the aligned cells were driven into the separation channel and rapidly lysed within 33ms at the entry of the separation channel by Triton X-100 added in the sheath-flow solution. The maximum rate for introducing individual cells into the separation channel was about 150cells/min. The introduction of sheath-flow streams also significantly reduced the concentration of phosphate-buffered saline (PBS) injected into the separation channel along with single cells, thus reducing Joule heating during electrophoretic separation. The performance of this microfluidic system was evaluated by analysis of reduced glutathione (GSH) and reactive oxygen species (ROS) in single erythrocytes. A throughput of 38cells/min was obtained. The proposed method is simple and robust for high-throughput single-cell analysis, allowing for analysis of cell population with considerable size to generate results with statistical significance. Copyright © 2010 Elsevier B.V. All rights reserved.
Hénaux, Viviane; Calavas, Didier
2017-01-01
Surveillance systems of exotic infectious diseases aim to ensure transparency about the country-specific animal disease situation (i.e. demonstrate disease freedom) and to identify any introductions. In a context of decreasing resources, evaluation of surveillance efficiency is essential to help stakeholders make relevant decisions about prioritization of measures and funding allocation. This study evaluated the efficiency (sensitivity related to cost) of the French bovine brucellosis surveillance system using stochastic scenario tree models. Cattle herds were categorized into three risk groups based on the annual number of purchases, given that trading is considered as the main route of brucellosis introduction in cattle herds. The sensitivity in detecting the disease and the costs of the current surveillance system, which includes clinical (abortion) surveillance, programmed serological testing and introduction controls, were compared to those of 19 alternative surveillance scenarios. Surveillance costs included veterinary fees and laboratory analyses. The sensitivity over a year of the current surveillance system was predicted to be 91±7% at a design prevalence of 0.01% for a total cost of 14.9±1.8 million €. Several alternative surveillance scenarios, based on clinical surveillance and random or risk-based serological screening in a sample (20%) of the population, were predicted to be at least as sensitive but for a lower cost. Such changes would reduce whole surveillance costs by 20 to 61% annually, and the costs for farmers only would be decreased from about 12.0 million € presently to 5.3-9.0 million € (i.e. 25-56% decrease). Besides, fostering the evolution of the surveillance system in one of these directions would be in agreement with the European regulations and farmers perceptions on brucellosis risk and surveillance.
Calavas, Didier
2017-01-01
Surveillance systems of exotic infectious diseases aim to ensure transparency about the country-specific animal disease situation (i.e. demonstrate disease freedom) and to identify any introductions. In a context of decreasing resources, evaluation of surveillance efficiency is essential to help stakeholders make relevant decisions about prioritization of measures and funding allocation. This study evaluated the efficiency (sensitivity related to cost) of the French bovine brucellosis surveillance system using stochastic scenario tree models. Cattle herds were categorized into three risk groups based on the annual number of purchases, given that trading is considered as the main route of brucellosis introduction in cattle herds. The sensitivity in detecting the disease and the costs of the current surveillance system, which includes clinical (abortion) surveillance, programmed serological testing and introduction controls, were compared to those of 19 alternative surveillance scenarios. Surveillance costs included veterinary fees and laboratory analyses. The sensitivity over a year of the current surveillance system was predicted to be 91±7% at a design prevalence of 0.01% for a total cost of 14.9±1.8 million €. Several alternative surveillance scenarios, based on clinical surveillance and random or risk-based serological screening in a sample (20%) of the population, were predicted to be at least as sensitive but for a lower cost. Such changes would reduce whole surveillance costs by 20 to 61% annually, and the costs for farmers only would be decreased from about 12.0 million € presently to 5.3–9.0 million € (i.e. 25–56% decrease). Besides, fostering the evolution of the surveillance system in one of these directions would be in agreement with the European regulations and farmers perceptions on brucellosis risk and surveillance. PMID:28859107
Baron, Julianne L.; Vikram, Amit; Duda, Scott; Stout, Janet E.; Bibby, Kyle
2014-01-01
Drinking water distribution systems, including premise plumbing, contain a diverse microbiological community that may include opportunistic pathogens. On-site supplemental disinfection systems have been proposed as a control method for opportunistic pathogens in premise plumbing. The majority of on-site disinfection systems to date have been installed in hospitals due to the high concentration of opportunistic pathogen susceptible occupants. The installation of on-site supplemental disinfection systems in hospitals allows for evaluation of the impact of on-site disinfection systems on drinking water system microbial ecology prior to widespread application. This study evaluated the impact of supplemental monochloramine on the microbial ecology of a hospital’s hot water system. Samples were taken three months and immediately prior to monochloramine treatment and monthly for the first six months of treatment, and all samples were subjected to high throughput Illumina 16S rRNA region sequencing. The microbial community composition of monochloramine treated samples was dramatically different than the baseline months. There was an immediate shift towards decreased relative abundance of Betaproteobacteria, and increased relative abundance of Firmicutes, Alphaproteobacteria, Gammaproteobacteria, Cyanobacteria and Actinobacteria. Following treatment, microbial populations grouped by sampling location rather than sampling time. Over the course of treatment the relative abundance of certain genera containing opportunistic pathogens and genera containing denitrifying bacteria increased. The results demonstrate the driving influence of supplemental disinfection on premise plumbing microbial ecology and suggest the value of further investigation into the overall effects of premise plumbing disinfection strategies on microbial ecology and not solely specific target microorganisms. PMID:25033448
Baron, Julianne L; Vikram, Amit; Duda, Scott; Stout, Janet E; Bibby, Kyle
2014-01-01
Drinking water distribution systems, including premise plumbing, contain a diverse microbiological community that may include opportunistic pathogens. On-site supplemental disinfection systems have been proposed as a control method for opportunistic pathogens in premise plumbing. The majority of on-site disinfection systems to date have been installed in hospitals due to the high concentration of opportunistic pathogen susceptible occupants. The installation of on-site supplemental disinfection systems in hospitals allows for evaluation of the impact of on-site disinfection systems on drinking water system microbial ecology prior to widespread application. This study evaluated the impact of supplemental monochloramine on the microbial ecology of a hospital's hot water system. Samples were taken three months and immediately prior to monochloramine treatment and monthly for the first six months of treatment, and all samples were subjected to high throughput Illumina 16S rRNA region sequencing. The microbial community composition of monochloramine treated samples was dramatically different than the baseline months. There was an immediate shift towards decreased relative abundance of Betaproteobacteria, and increased relative abundance of Firmicutes, Alphaproteobacteria, Gammaproteobacteria, Cyanobacteria and Actinobacteria. Following treatment, microbial populations grouped by sampling location rather than sampling time. Over the course of treatment the relative abundance of certain genera containing opportunistic pathogens and genera containing denitrifying bacteria increased. The results demonstrate the driving influence of supplemental disinfection on premise plumbing microbial ecology and suggest the value of further investigation into the overall effects of premise plumbing disinfection strategies on microbial ecology and not solely specific target microorganisms.
Optimal Inspection of Imports to Prevent Invasive Pest Introduction.
Chen, Cuicui; Epanchin-Niell, Rebecca S; Haight, Robert G
2018-03-01
The United States imports more than 1 billion live plants annually-an important and growing pathway for introduction of damaging nonnative invertebrates and pathogens. Inspection of imports is one safeguard for reducing pest introductions, but capacity constraints limit inspection effort. We develop an optimal sampling strategy to minimize the costs of pest introductions from trade by posing inspection as an acceptance sampling problem that incorporates key features of the decision context, including (i) simultaneous inspection of many heterogeneous lots, (ii) a lot-specific sampling effort, (iii) a budget constraint that limits total inspection effort, (iv) inspection error, and (v) an objective of minimizing cost from accepted defective units. We derive a formula for expected number of accepted infested units (expected slippage) given lot size, sample size, infestation rate, and detection rate, and we formulate and analyze the inspector's optimization problem of allocating a sampling budget among incoming lots to minimize the cost of slippage. We conduct an empirical analysis of live plant inspection, including estimation of plant infestation rates from historical data, and find that inspections optimally target the largest lots with the highest plant infestation rates, leaving some lots unsampled. We also consider that USDA-APHIS, which administers inspections, may want to continue inspecting all lots at a baseline level; we find that allocating any additional capacity, beyond a comprehensive baseline inspection, to the largest lots with the highest infestation rates allows inspectors to meet the dual goals of minimizing the costs of slippage and maintaining baseline sampling without substantial compromise. © 2017 Society for Risk Analysis.
Application of an ETV-ICP system for the determination of elements in human hair*1
NASA Astrophysics Data System (ADS)
Plantikow-Voβgätter, F.; Denkhaus, E.
1996-01-01
When determining element contents in hair samples without sample digestion it is necessary to analyze large sample volumes in order to minimize problems of inhomogeneity of biological sample materials. Therefore an electrothermal vaporization system (ETV) is used for solid sample introduction into an inductively coupled plasma (ICP) for the determination of matrix and trace elements in hair. This paper concentrates on the instrumental aspects without time consuming sample preparation. The results obtained for optimization tests, ETV operating parameters and ICP operating parameters, are shown and discussed. Standard additions are used for calibration for the determination of Zn, Mg, and Mn in human hair. Studies including reproducibility and detection limits for chosen elements have been carried out on certified reference materials (CRMs). The determination of reproducibility (relative standard deviation (RSD) of n = 10) and detection limits (DLs) of Zn (RSD < 8.5%, DL < 0.8 μ g -1), Mn (RSD < 14.1%, DL < 0.3 μ g -1), and Mg (RSD < 7.4%, DL < 6.6 μ g -1) are satisfactory. The concentration values found show good agreement with the corresponding certified values. Further sample preparation steps, including hair sampling, washing procedure and homogenization for hair, relating to measurements of real hair samples are described.
Ultrasonically Assisted Cutting of Bio-tissues in Microtomy
NASA Astrophysics Data System (ADS)
Wang, Dong; Roy, Anish; Silberschmidt, Vadim V.
Modern-day histology of bio-tissues for supporting stratified medicine diagnoses requires high-precision cutting to ensure high quality extremely thin specimens used in analysis. Additionally, the cutting quality is significantly affected by a wide variety of soft and hard tissues in the samples. This paper deals with development of a next generation of microtome employing introduction of controlled ultrasonic vibration to realise a hybrid cutting process of bio-tissues. The study is based on a combination of advanced experimental and numerical (finite-element) studies of multi-body dynamics of a cutting system. The quality of cut samples produced with the prototype is compared with the state-of-the-art.
Wages, Jennifer A; Williams, Jennifer; Adams, Jacquelyn; George, Bruce; Oxford, Eric; Zelenka, Dan
2014-11-01
Inoculated beef trim containing a cocktail of green fluorescent protein-marked Escherichia coli biotype I cultures as surrogates for E. coli O157:H7 was introduced into two large, commercial grinding facilities capable of producing 180,000 kg of ground product in 1 day. Three repetitions were performed over 3 days. Sampling occurred at three different points within the process: postprimary grind, postsecondary grind-blender, and postpackaging. Resulting data show that, as the inoculated meat passes through the system, the presence of the marked surrogate quickly diminishes. The depletion rates are directly related to the amount of product in kilograms (represented by time) that has passed through the system, but these rates vary with each step of the process. The primary grinder appears to rid itself of the contaminant the most quickly; in all repetitions, the contaminant was not detected within 5 min of introduction of the contaminated combo bin into the system, which in all cases, was prior to the introduction of a second combo bin and within 1,800 kg of product. After the blending step and subsequent secondary grinding, the contaminant was detected in product produced from both the parent combo and the combo bin added directly after the parent combo bin; however, for those days on which three combo bins (approximately 2,700 kg) were available for sampling, the contaminant was not detected from product representing the third combo bin. Similarly, at the packaging step, the contaminant was detected in the product produced by both the parent and second combo bins; however, on those days when a third combo bin was available for sampling (repetitions 2 and 3), the contaminant was not detected from product produced from the third combo bin.
Garrido-Delgado, Rocío; Arce, Lourdes; Valcárcel, Miguel
2012-01-01
The potential of a headspace device coupled to multi-capillary column-ion mobility spectrometry has been studied as a screening system to differentiate virgin olive oils ("lampante," "virgin," and "extra virgin" olive oil). The last two types are virgin olive oil samples of very similar characteristics, which were very difficult to distinguish with the existing analytical method. The procedure involves the direct introduction of the virgin olive oil sample into a vial, headspace generation, and automatic injection of the volatiles into a gas chromatograph-ion mobility spectrometer. The data obtained after the analysis by duplicate of 98 samples of three different categories of virgin olive oils, were preprocessed and submitted to a detailed chemometric treatment to classify the virgin olive oil samples according to their sensory quality. The same virgin olive oil samples were also analyzed by an expert's panel to establish their category and use these data as reference values to check the potential of this new screening system. This comparison confirms the potential of the results presented here. The model was able to classify 97% of virgin olive oil samples in their corresponding group. Finally, the chemometric method was validated obtaining a percentage of prediction of 87%. These results provide promising perspectives for the use of ion mobility spectrometry to differentiate virgin olive oil samples according to their quality instead of using the classical analytical procedure.
James, Sindiwe; Miza, Thenjiwe M
2015-03-09
The South African health care delivery system has shifted focus to primary health care since 1994. For this purpose the Batho Pele principles were introduced. Nurses claim, however, that since the introduction of these principles patients and their families have been making unnecessary and sometimes impossible demands of nursing staff. This article presents the perceptions of the professional nurses regarding the introduction of the Batho Pele principles in their workplace. To describe the perceptions of professional nurses regarding introduction of the Batho Pele principles and to recommend guidelines to facilitate measures to realise the objects of these principles. A qualitative, exploratory, descriptive and contexual research design was used. Six audio-taped focus group discussions and field notes were used to collect data from purposively sampled participants who have worked in the outpatient departments of hospitals in the Port Elizabeth Hospital Complex. Guba's model of trustworthiness was used to confirm integrity of the study, whilst the participants were kept anonymous, protected from harm and participated voluntarily. Data analysis was done using Tesch's data analysis spiral and with the involvement of an independent-coder. Three themes emerged, revealing that the professional nurses perceived the objectives of the Batho Pele principles as difficult to uphold due to the inadequate planning prior to their implementation. Inadequacy of human and material resources aggravated this perception. Professional nurses are not happy with how things are in terms of introduction of the Batho Pele principles, but are optimistic of a positive change in the near future.
NASA Astrophysics Data System (ADS)
Duan, Yixiang; Su, Yongxuan; Jin, Zhe; Abeln, Stephen P.
2000-03-01
The development of a highly sensitive, field portable, low-powered instrument for on-site, real-time liquid waste stream monitoring is described in this article. A series of factors such as system sensitivity and portability, plasma source, sample introduction, desolvation system, power supply, and the instrument configuration, were carefully considered in the design of the portable instrument. A newly designed, miniature, modified microwave plasma source was selected as the emission source for spectroscopy measurement, and an integrated small spectrometer with a charge-coupled device detector was installed for signal processing and detection. An innovative beam collection system with optical fibers was designed and used for emission signal collection. Microwave plasma can be sustained with various gases at relatively low power, and it possesses high detection capabilities for both metal and nonmetal pollutants, making it desirable to use for on-site, real-time, liquid waste stream monitoring. An effective in situ sampling system was coupled with a high efficiency desolvation device for direct-sampling liquid samples into the plasma. A portable computer control system is used for data processing. The new, integrated instrument can be easily used for on-site, real-time monitoring in the field. The system possesses a series of advantages, including high sensitivity for metal and nonmetal elements; in situ sampling; compact structure; low cost; and ease of operation and handling. These advantages will significantly overcome the limitations of previous monitoring techniques and make great contributions to environmental restoration and monitoring.
NASA Astrophysics Data System (ADS)
Atkinson, D. B.
2001-12-01
Modulation of volatile hydrocarbons in two-component mixtures is demonstrated using an ozonolysis pretreatment with membrane introduction mass spectrometry (MIMS). The MIMS technique allows selective introduction of volatile and semivolatile analytes into a mass spectrometer via processes known collectively as pervaporation [Kotiaho and Cooks, 1992]. A semipermeable polymer membrane acts as an interface between the sample (vapor or solution) and the vacuum of the mass spectrometer. This technique has been demonstrated to allow for sensitive analysis of hydrocarbons and other non-polar volatile organic compounds (VOC`s) in air samples[Cisper et al., 1995] . The methodology has the advantages of no sample pretreatment and short analysis time, which are promising for online monitoring applications but the chief disadvantage of lack of a separation step for the different analytes in a mixture. Several approaches have been investigated to overcome this problem including use of selective chemical ionization [Bier and Cooks, 1987] and multivariate calibration techniques[Ketola et al., 1999] . A new approach is reported for the quantitative measurement of VOCs in complex matrices. The method seeks to reduce the complexity of mass spectra observed in hydrocarbon mixture analysis by selective pretreatment of the analyte mixture. In the current investigation, the rapid reaction of ozone with alkenes is used, producing oxygenated compounds which are suppressed by the MIMS system. This has the effect of removing signals due to unsaturated analytes from the compound mass spectra, and comparison of the spectra before and after the ozone treatment reveals the nature of the parent compounds. In preliminary investigations, ozone reacted completely with cyclohexene from a mixture of cylohexene and cyclohexane, and with β -pinene from a mixture of toluene and β -pinene, suppressing the ion signals from the olefins. A slight attenuation of the cyclohexane and toluene in those mixtures was also observed. Despite this problem, the hydrocarbon signal response can be calibrated and the method can be used for quantitative analysis of volatile hydrocarbon compounds in air samples. This methodology should augment the efficiency of the MIMS approach in online and onsite monitoring of VOC emissions. Bier, M.R., and R.G. Cooks, Membrane Interface for Selective Introduction of Volatile Compounds Directly into The Ionization Chamber of a Mass Spectrometer, Anal. Chem., 59 (4), 597, 1987. Cisper, M.E., C.G. Gill, L.E. Townsend, and P.H. Hemberger, On-Line Detection of Volatile Organic Compounds in Air at Parts-per-Trillion Levels by Membrane Introduction Mass Spectrometry, Anal. Chem., 67 (8), 1413-1417, 1995. Ketola, R.A., M. Ojala, and J. Heikkonen, A Non-linear Asymmetric Error Function-based Least Mean Square Approach for the Analysis of Multicomponent Mass Spectra Measured by Membrane Inlet Mass Spectrometry, Rapid Commun. Mass Spectrom., 13 (8), 654, 1999. Kotiaho, T., and R.G. Cooks, Membrane Introduction Mass Spectrometry in Environmental Analysis, in: J.J. Breen, M. J. Dellarco, (Eds), Pollution in Industrial processes, 126 pp., ACS Symp. Ser., Washington, D.C. 508, 1992.
Wozniak, Jeffrey R; Thies, Monte L; Bytheway, Joan A; Lutterschmidt, William I
2015-01-01
Forensic taphonomy is an essential research field; however, the decomposition of human cadavers at forensic science facilities may lead to nutrient loading and the introduction of unique biological compounds to adjacent areas. The infrastructure of a water retention system may provide a mechanism for the biogeochemical processing and retention of nutrients and compounds, ensuring the control of runoff from forensic facilities. This work provides a proof of concept for a hydrologic retention system and an autonomous water quality monitoring program designed to mitigate runoff from The Southeast Texas Applied Forensic Science (STAFS) Facility. Water samples collected along a sample transect were analyzed for total phosphorous, total nitrogen, NO3-, NO2-, NH4, F(-), and Cl(-). Preliminary water quality analyses confirm the overall effectiveness of the water retention system. These results are discussed with relation to how this infrastructure can be expanded upon to monitor additional, more novel, byproducts of forensic science research facilities. © 2014 American Academy of Forensic Sciences.
The Effect of Values on System Development Project Outcomes
2009-03-01
before me and upon whose broad shoulders I stand. Men like Col John Boyd (USAF, ret), Col Chet Richards (USAF, ret), Col James Burton (USAF, ret), Chuck...with new homes that could have housed more than 8,000 people. - President Dwight D. Eisenhower, April 19, 1953 I. Introduction This research...Boyne, 2007 RUBRIC SCORE: 30 F-Score:10 I-Score: 5 S-Score:10 T-Score:5 OUTCOME: A SAMPLE STATEMENTS: FAST “The Navy men liked everything
NOAA Homeland Security Program Office
Emergency Managment Institute IS 100.b - Introduction to Incident Command System IS 700.a - NIMS An Introduction IS 701.b - NIMS Multiagency Coordination System (MACS) Course IS 800.b - National Response Framework, An Introduction United States Coast Guard; Maritime Domain Awareness Privacy Act Statement
Cui, Wenbin; Zheng, Peiyong; Yang, Jiahong; Zhao, Rong; Gao, Jiechun; Yu, Guangjun
2015-02-01
Biobanks are important resources and central tools for translational medicine, which brings scientific research outcomes to clinical practice. The key purpose of biobanking in translational medicine and other medical research is to provide biological samples that are integrated with clinical information. In 2008, the Shanghai Municipal Government launched the "Shanghai Tissue Bank" in an effort to promote research in translational medicine. Now a sharing service platform has been constructed to integrate clinical practice and biological information that can be used in diverse medical and pharmaceutical research studies. The platform collects two kinds of data: sample data and clinical data. The sample data are obtained from the hospital biobank management system, and mainly include the donors' age, gender, marital status, sample source, sample type, collection time, deposit time, and storage method. The clinical data are collected from the "Hospital-Link" system (a medical information sharing system that connects 23 tertiary hospitals in Shanghai). The main contents include donors' corresponding medication information, test reports, inspection reports, and hospital information. As of the end of September 2014, the project has a collection of 16,020 donors and 148,282 samples, which were obtained from 12 medical institutions, and automatically acquired donors' corresponding clinical data from the "Hospital-Link" system for 6830 occurrences. This project will contribute to scientific research at medical institutions in Shanghai, and will also support the development of the biopharmaceutical industry. In this article, we will describe the significance, the construction phases, the application prospects, and benefits of the sample repository and information sharing service platform.
Fall Protection Introduction, #33462
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chochoms, Michael
The proper use of fall prevention and fall protection controls can reduce the risk of deaths and injuries caused by falls. This course, Fall Protection Introduction (#33462), is designed as an introduction to various types of recognized fall prevention and fall protection systems at Los Alamos National Laboratory (LANL), including guardrail systems, safety net systems, fall restraint systems, and fall arrest systems. Special emphasis is given to the components, inspection, care, and storage of personal fall arrest systems (PFASs). This course also presents controls for falling object hazards and emergency planning considerations for persons who have fallen.
JAMSTEC DARWIN Database Assimilates GANSEKI and COEDO
NASA Astrophysics Data System (ADS)
Tomiyama, T.; Toyoda, Y.; Horikawa, H.; Sasaki, T.; Fukuda, K.; Hase, H.; Saito, H.
2017-12-01
Introduction: Japan Agency for Marine-Earth Science and Technology (JAMSTEC) archives data and samples obtained by JAMSTEC research vessels and submersibles. As a common property of the human society, JAMSTEC archive is open for public users with scientific/educational purposes [1]. For publicizing its data and samples online, JAMSTEC is operating NUUNKUI data sites [2], a group of several databases for various data and sample types. For years, data and metadata of JAMSTEC rock samples, sediment core samples and cruise/dive observation were publicized through databases named GANSEKI, COEDO, and DARWIN, respectively. However, because they had different user interfaces and data structures, these services were somewhat confusing for unfamiliar users. Maintenance costs of multiple hardware and software were also problematic for performing sustainable services and continuous improvements. Database Integration: In 2017, GANSEKI, COEDO and DARWIN were integrated into DARWIN+ [3]. The update also included implementation of map-search function as a substitute of closed portal site. Major functions of previous systems were incorporated into the new system; users can perform the complex search, by thumbnail browsing, map area, keyword filtering, and metadata constraints. As for data handling, the new system is more flexible, allowing the entry of variety of additional data types. Data Management: After the DARWIN major update, JAMSTEC data & sample team has been dealing with minor issues of individual sample data/metadata which sometimes need manual modification to be transferred to the new system. Some new data sets, such as onboard sample photos and surface close-up photos of rock samples, are getting available online. Geochemical data of sediment core samples will supposedly be added in the near future. Reference: [1] http://www.jamstec.go.jp/e/database/data_policy.html [2] http://www.godac.jamstec.go.jp/jmedia/portal/e/ [3] http://www.godac.jamstec.go.jp/darwin/e/
An assessment of drinking-water quality post-Haiyan
Anarna, Maria Sonabel; Fernando, Arturo
2015-01-01
Introduction Access to safe drinking-water is one of the most important public health concerns in an emergency setting. This descriptive study reports on an assessment of water quality in drinking-water supply systems in areas affected by Typhoon Haiyan immediately following and 10 months after the typhoon. Methods Water quality testing and risk assessments of the drinking-water systems were conducted three weeks and 10 months post-Haiyan. Portable test kits were used to determine the presence of Escherichia coli and the level of residual chlorine in water samples. The level of risk was fed back to the water operators for their action. Results Of the 121 water samples collected three weeks post-Haiyan, 44% were contaminated, while 65% (244/373) of samples were found positive for E. coli 10 months post-Haiyan. For the three components of drinking-water systems – source, storage and distribution – the proportions of contaminated systems were 70%, 67% and 57%, respectively, 10 months after Haiyan. Discussion Vulnerability to faecal contamination was attributed to weak water safety programmes in the drinking-water supply systems. Poor water quality can be prevented or reduced by developing and implementing a water safety plan for the systems. This, in turn, will help prevent waterborne disease outbreaks caused by contaminated water post-disaster. PMID:26767136
NASA Astrophysics Data System (ADS)
Chiou, Chwei-Sheng; Jiang, Shiuh-Jen; Kumar Danadurai, K. Suresh
2001-07-01
A method employing a vapor generation system and LC combined with inductively coupled plasma mass spectrometry (LC-ICP-MS) is presented for the determination of mercury in biological tissues. An open vessel microwave digestion system was used to extract the mercury compounds from the sample matrix. The efficiency of the mobile phase, a mixture of L-cysteine and 2-mercaptoethanol, was evaluated for LC separation of inorganic mercury [Hg(II)], methylmercury (methyl-Hg) and ethylmercury (ethyl-Hg). The sensitivity, detection limits and repeatability of the liquid chromatography (LC) ICP-MS system with a vapor generator were comparable to, or better than, that of an LC-ICP-MS system with conventional pneumatic nebulization, or other sample introduction techniques. The experimental detection limits for various mercury species were in the range of 0.05-0.09 ng ml -1 Hg, based on peak height. The proposed method was successfully applied to the determination of mercury compounds in a swordfish sample purchased from the local market. The accuracy of the method was evaluated by analyzing a marine biological certified reference material (DORM-2, NRCC).
76 FR 13242 - Change in Postal Prices
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-10
[email protected] (electronic filing assistance). SUPPLEMENTARY INFORMATION: Table of Contents I. Introduction II. Notice of Filings III. Ordering Paragraphs I. Introduction On March 1, 2011, the Commission... Postal Service-branded parcel box designed to contain product samples and other advertising material from...
Criado-García, Laura; Garrido-Delgado, Rocío; Arce, Lourdes; Valcárcel, Miguel
2013-07-15
An UV-Ion Mobility Spectrometer is a simple, rapid, inexpensive instrument widely used in environmental analysis among other fields. The advantageous features of its underlying technology can be of great help towards developing reliable, economical methods for determining gaseous compounds from gaseous, liquid and solid samples. Developing an effective method using UV-Ion Mobility Spectrometry (UV-IMS) to determine volatile analytes entails using appropriate gaseous standards for calibrating the spectrometer. In this work, two home-made sample introduction systems (SISs) and a commercial gas generator were used to obtain such gaseous standards. The first home-made SIS used was a static head-space to measure compounds present in liquid samples and the other home-made system was an exponential dilution set-up to measure compounds present in gaseous samples. Gaseous compounds generated by each method were determined on-line by UV-IMS. Target analytes chosen for this comparative study were ethanol, acetone, benzene, toluene, ethylbenzene and xylene isomers. The different alternatives were acceptable in terms of sensitivity, precision and selectivity. Copyright © 2013 Elsevier B.V. All rights reserved.
Boulyga, Sergei F; Heumann, Klaus G
2006-01-01
A method by inductively coupled plasma mass spectrometry (ICP-MS) was developed which allows the measurement of (236)U at concentration ranges down to 3 x 10(-14)g g(-1) and extremely low (236)U/(238)U isotope ratios in soil samples of 10(-7). By using the high-efficiency solution introduction system APEX in connection with a sector-field ICP-MS a sensitivity of more than 5,000 counts fg(-1) uranium was achieved. The use of an aerosol desolvating unit reduced the formation rate of uranium hydride ions UH(+)/U(+) down to a level of 10(-6). An abundance sensitivity of 3 x 10(-7) was observed for (236)U/(238)U isotope ratio measurements at mass resolution 4000. The detection limit for (236)U and the lowest detectable (236)U/(238)U isotope ratio were improved by more than two orders of magnitude compared with corresponding values by alpha spectrometry. Determination of uranium in soil samples collected in the vicinity of Chernobyl nuclear power plant (NPP) resulted in that the (236)U/(238)U isotope ratio is a much more sensitive and accurate marker for environmental contamination by spent uranium in comparison to the (235)U/(238)U isotope ratio. The ICP-MS technique allowed for the first time detection of irradiated uranium in soil samples even at distances more than 200 km to the north of Chernobyl NPP (Mogilev region). The concentration of (236)U in the upper 0-10 cm soil layers varied from 2 x 10(-9)g g(-1) within radioactive spots close to the Chernobyl NPP to 3 x 10(-13)g g(-1) on a sampling site located by >200 km from Chernobyl.
Montaser, Akbar [Potomac, MD; Westphal, Craig S [Landenberg, PA; Kahen, Kaveh [Montgomery Village, MD; Rutkowski, William F [Arlington, VA
2008-01-08
An apparatus and method for providing direct liquid sample introduction using a nebulizer are provided. The apparatus and method include a short torch having an inner tube and an outer tube, and an elongated adapter having a cavity for receiving the nebulizer and positioning a nozzle tip of the nebulizer a predetermined distance from a tip of the outer tube of the short torch. The predetermined distance is preferably about 2-5 mm.
Computer Simulation of a Multiaxis Air-to-Air Tracking Task Using the Optimal Pilot Control Model.
1982-12-01
v ABSTRACT ........ ............................. .. vi CHAPTER 1 - INTRODUCTION ....... ..................... 1 1.1 Motivation... Introduction ......... . 4 2.2 Optimal Pilot Control Model and Control Synthesis 4 2.3 Pitch Tracking Task ...... ................... 6 2.4 Multiaxis...CHAPTER 3 - SIMULATION SYSTEM ...... .................. 33 3.1 Introduction ........ ....................... 33 3.2 System Hardware
NASA Astrophysics Data System (ADS)
Rossing, Thomas
This brief introduction may help to persuade the reader that acoustics covers a wide range of interesting topics. It is impossible to cover all these topics in a single handbook, but we have attempted to include a sampling of hot topics that represent current acoustical research, both fundamental and applied.
NASA Technical Reports Server (NTRS)
Eigenbrode, J. L.; Glavin, D.; Coll, P.; Summons, R. E.; Mahaffy, P.; Archer, D.; Brunner, A.; Conrad, P.; Freissinet, C.; Martin, M.;
2013-01-01
key challenge in assessing the habitability of martian environments is the detection of organic matter - a requirement of all life as we know it. The Curiosity rover, which landed on August 6, 2012 in Gale Crater of Mars, includes the Sample Analysis at Mars (SAM) instrument suite capable of in situ analysis of gaseous organic components thermally evolved from sediment samples collected, sieved, and delivered by the MSL rover. On Sol 94, SAM received its first solid sample: scooped sediment from Rocknest that was sieved to <150 m particle size. Multiple 10-40 mg portions of the scoop #5 sample were delivered to SAM for analyses. Prior to their introduction, a blank (empty cup) analysis was performed. This blank served 1) to clean the analytical instrument of SAMinternal materials that accumulated in the gas processing system since integration into the rover, and 2) to characterize the background signatures of SAM. Both the blank and the Rocknest samples showed the presence of hydrocarbon components.
1984-06-01
Aquatic Plant Management Program: Water Quality Monitoring, by John H. Rodgers, Jr., Kevin H. Reinert, and Mark L. Hinman...Rodgers, Jr.,* Kevin H. Reinert,* and Mark L. Hinman* Din INTRODUCTION 0 A water quality monitoring program was conducted on Pat Mayse Lake during...Mississippi. 117 Herbicide Sprayer Plant Bed Translucen- Rof -SupplementalLighting_ Waer Supply _ W i Sampling Stations Figure 1. Flume system set up to
Adaptive Control and Parameter Identification of a Doubly-Fed Induction Generator for Wind Power
2011-09-01
Computer Controlled Systems, Theory and Design, Third Edition, Prentice Hall, New Jersey, 1997. [27] R. G. Brown and P. Y.C. Hwang , Introduction to...V n y iT iT , (0.0) with Ts as the sampling interval. From [26], the recursive estimate can be interpreted as a Kalman Filter for the process...by substituting t with n. The recursive equations for the RLS can then be derived from the Kalman filter equations used in [27]: 29 $ $ $ 1 1
2012-09-01
basic form of phosphoric acid or sodium phosphate NO2- Nitrite OH- Hydroxide ion ERDC/EL TR-12-14 1 1 Introduction Alkaline hydrolysis has...into amber sample vials and refrigerated until analyzed. TNT analyses were conducted by high performance liquid chromatography (HPLC) with a C-18...The explosives concentrations of the different soils were quantified using a DIONEX HPLC system equipped with a C-18 reverse phase column and a
NASA Technical Reports Server (NTRS)
Anbar, A. D.; Zhang, C.; Barling, J.; Roe, J. E.; Nealson, K. H.
1999-01-01
The importance of Fe biogeochemistry has stimulated interest in Fe isotope fractionation. Recent studies using thermal ionization mass spectrometry (TIMS) and a "double spike" demonstrate the existence of biogenic Fe isotope effects. Here, we assess the utility of multiple-collector inductively-coupled plasma mass spectrometry(MC-ICP-MS) with a desolvating sample introduction system for Fe isotope studies, and present data on Fe biominerals produced by a thermophilic bacterium. Additional information is contained in the original extended abstract.
ONUMA, Manabu; KAKOGAWA, Masayoshi; YANAGISAWA, Masae; HAGA, Atsushi; OKANO, Tomomi; NEAGARI, Yasuko; OKANO, Tsukasa; GOKA, Koichi; ASAKAWA, Mitsuhiko
2017-01-01
The objectives of the present study were to observe the temporal pattern of avian influenza virus (AIV) introduction into Japan and to determine which migratory birds play an important role in introducing AIV. In total, 19,407 fecal samples from migratory birds were collected at 52 sites between October 2008 and May 2015. Total nucleic acids extracted from the fecal samples were subjected to reverse transcription loop–mediated isothermal amplification to detect viral RNA. Species identification of host migratory birds was conducted by DNA barcoding for positive fecal samples. The total number of positive samples was 352 (prevalence, 1.8%). The highest prevalence was observed in autumn migration, and a decrease in prevalence was observed. During autumn migration, central to southern Japan showed a prevalence higher than the overall prevalence. Thus, the main AIV entry routes may involve crossing the Sea of Japan and entry through the Korean Peninsula. Species identification was successful in 221 of the 352 positive samples. Two major species sequences were identified: the Mallard/Eastern Spot-billed duck group (115 samples; 52.0%) and the Northern pintail (61 samples; 27.6%). To gain a better understanding of the ecology of AIV in Japan and the introduction pattern of highly pathogenic avian influenza viruses, information regarding AIV prevalence by species, the prevalence of hatch-year migratory birds, migration patterns and viral subtypes in fecal samples using egg inoculation and molecular-based methods in combination is required. PMID:28484128
Human Immune Function and Microbial Pathogenesis in Human Spaceflight
NASA Technical Reports Server (NTRS)
Pierson, Duane J.; Ott, M.
2006-01-01
This oral presentation was requested by Conference conveners. The requested subject is microbial risk assessment considering changes in the human immune system during flight and microbial diversity of environmental samples aboard the International Space Station (ISS). The presentation will begin with an introduction discussing the goals and limitations of microbial risk assessment during flight. The main portion of the presentation will include changes in the immune system that have been published, historical data from microbial analyses, and initial modeling of the environmental flora aboard ISS. The presentation will conclude with future goals and techniques to enhance our ability to perform microbial risk assessment on long duration missions.
Management of healthcare waste: developments in Southeast Asia in the twenty-first century.
Kühling, Jan-Gerd; Pieper, Ute
2012-09-01
In many Southeast Asian countries, significant challenges persist with regard to the proper management and disposal of healthcare waste. The amount of healthcare waste in these countries is continuously increasing as a result of the expansion of healthcare systems and services. In the past, healthcare waste, if it was treated at all, was mainly incinerated. In the last decade more comprehensive waste management systems were developed for Southeast Asian countries and implementation started. This also included the establishment of alternative healthcare waste treatment systems. The developments in the lower-middle-income countries are of special interest, as major investments are planned. Based upon sample projects, a short overview of the current development trends in the healthcare waste sector in Laos, Indonesia and Vietnam is provided. The projects presented include: (i) Lao Peoples Democratic Republic (development of the national environmental health training system to support the introduction of environmental health standards and improvement of healthcare waste treatment in seven main hospitals by introducing steam-based treatment technologies); (ii) Indonesia (development of a provincial-level healthcare waste-management strategy for Province Nanggroe Aceh Darussalam (NAD) and introduction of an advanced waste treatment system in a tertiary level hospital in Makassar); and (iii) Vietnam (development of a healthcare waste strategy for five provinces in Vietnam and a World Bank-financed project on healthcare waste in Vietnam).
Jiang, Xiaogang; Feng, Shun; Tian, Ruijun; Han, Guanghui; Jiang, Xinning; Ye, Mingliang; Zou, Hanfa
2007-02-01
An approach was developed to automate sample introduction for nanoflow LC-MS/MS (microLC-MS/MS) analysis using a strong cation exchange (SCX) trap column. The system consisted of a 100 microm id x 2 cm SCX trap column and a 75 microm id x 12 cm C18 RP analytical column. During the sample loading step, the flow passing through the SCX trap column was directed to waste for loading a large volume of sample at high flow rate. Then the peptides bound on the SCX trap column were eluted onto the RP analytical column by a high salt buffer followed by RP chromatographic separation of the peptides at nanoliter flow rate. It was observed that higher performance of separation could be achieved with the system using SCX trap column than with the system using C18 trap column. The high proteomic coverage using this approach was demonstrated in the analysis of tryptic digest of BSA and yeast cell lysate. In addition, this system was also applied to two-dimensional separation of tryptic digest of human hepatocellular carcinoma cell line SMMC-7721 for large scale proteome analysis. This system was fully automated and required minimum changes on current microLC-MS/MS system. This system represented a promising platform for routine proteome analysis.
Lasić, Lejla; Lojo-Kadrić, Naida; Silajdžić, Elma; Pojskić, Lejla; Hadžiselimović, Rifat; Pojskić, Naris
2013-01-01
There are two major theories for inheritance of Rh blood group system: Fisher – Race theory and Wiener theory. Aim of this study was identifying frequency of RHDCE alleles in Bosnian – Herzegovinian population and introduction of this method in screening for Rh phenotype in B&H since this type of analysis was not used for blood typing in B&H before. Rh blood group was typed by Polymerase Chain Reaction, using the protocols and primers previously established by other authors, then carrying out electrophoresis in 2-3% agarose gel. Percentage of Rh positive individuals in our sample is 84.48%, while the percentage of Rh negative individuals is 15.52%. Inter-rater agreement statistic showed perfect agreement (K=1) between the results of Rh blood system detection based on serological and molecular-genetics methods. In conclusion, molecular – genetic methods are suitable for prenatal genotyping and specific cases while standard serological method is suitable for high-throughput of samples. PMID:23448604
Shearer, Jessica C; Walker, Damian G; Risko, Nicholas; Levine, Orin S
2012-12-14
A surge of new and underutilized vaccine introductions into national immunization programmes has called into question the effect of new vaccine introduction on immunization and health systems. In particular, countries deciding whether to introduce a new or underutilized vaccine into their routine immunization programme may query possible effects on the delivery and coverage of existing vaccines. Using coverage of diphtheria-tetanus-pertussis (DTP) vaccine as a proxy for immunization system performance, this study aims to test whether new vaccine introduction into national immunization programs was associated with changes in coverage of three doses of DTP vaccine among infants. DTP3 vaccine coverage was analyzed in 187 countries during 1999-2009 using multivariable cross-national mixed-effect longitudinal models. Controlling for other possible determinants of DTP3 coverage at the national level these models found minimal association between the introduction of Hepatitis-, Haemophilus influenzae type b-, and rotavirus-containing vaccines and DTP3 coverage. Instead, frequent and sometimes large fluctuations in coverage are associated with other development and health systems variables, including the presence of armed conflict, coverage of antenatal care services, infant mortality, the percent of health expenditures that are private and total health expenditures per capita. Introductions of new vaccines did not affect national coverage of DTP3 vaccine in the countries studied. Introductions of other new vaccines and multiple vaccine introductions should be monitored for immunization and health systems impacts. Copyright © 2012 Elsevier Ltd. All rights reserved.
Experiments on Socio-Technical Systems: The Problem of Control.
Kroes, Peter
2016-06-01
My aim is to question whether the introduction of new technologies in society may be considered to be genuine experiments. I will argue that they are not, at least not in the sense in which the notion of experiment is being used in the natural and social sciences. If the introduction of a new technology in society is interpreted as an experiment, then we are dealing with a notion of experiment that differs in an important respect from the notion of experiment as used in the natural and social sciences. This difference shows itself most prominently when the functioning of the new technological system is not only dependent on technological hardware but also on social 'software', that is, on social institutions such as appropriate laws, and actions of operators of the new technological system. In those cases we are not dealing with 'simply' the introduction of a new technology, but with the introduction of a new socio-technical system. I will argue that if the introduction of a new socio-technical system is considered to be an experiment, then the relation between the experimenter and the system on which the experiment is performed differs significantly from the relation in traditional experiments in the natural and social sciences. In the latter experiments it is assumed that the experimenter is not part of the experimental system and is able to intervene in and control the experimental system from the outside. With regard to the introduction of new socio-technical systems the idea that there is an experimenter outside the socio-technical system who intervenes in and controls that system becomes problematic. From that perspective we are dealing with a different kind of experiment.
DOT National Transportation Integrated Search
1991-01-01
This manual was undertaken to record for all persons wishing to do concrete petrography the petrographic procedures that have been found useful here at the Virginia Transportation Research Council. This interim report is made up of the introduction, ...
LACIE performance predictor FOC users manual
NASA Technical Reports Server (NTRS)
1976-01-01
The LACIE Performance Predictor (LPP) is a computer simulation of the LACIE process for predicting worldwide wheat production. The simulation provides for the introduction of various errors into the system and provides estimates based on these errors, thus allowing the user to determine the impact of selected error sources. The FOC LPP simulates the acquisition of the sample segment data by the LANDSAT Satellite (DAPTS), the classification of the agricultural area within the sample segment (CAMS), the estimation of the wheat yield (YES), and the production estimation and aggregation (CAS). These elements include data acquisition characteristics, environmental conditions, classification algorithms, the LACIE aggregation and data adjustment procedures. The operational structure for simulating these elements consists of the following key programs: (1) LACIE Utility Maintenance Process, (2) System Error Executive, (3) Ephemeris Generator, (4) Access Generator, (5) Acquisition Selector, (6) LACIE Error Model (LEM), and (7) Post Processor.
NASA Astrophysics Data System (ADS)
Huang, Shih-Chiang; Lee, Gwo-Bin; Chien, Fan-Ching; Chen, Shean-Jen; Chen, Wen-Janq; Yang, Ming-Chang
2006-07-01
This paper presents a novel microfluidic system with integrated molecular imprinting polymer (MIP) films designed for surface plasmon resonance (SPR) biosensing of multiple nanoscale biomolecules. The innovative microfluidic chip uses pneumatic microvalves and micropumps to transport a precise amount of the biosample through multiple microchannels to sensing regions containing the locally spin-coated MIP films. The signals of SPR biosensing are basically proportional to the number of molecules adsorbed on the MIP films. Hence, a precise control of flow rates inside microchannels is important to determine the adsorption amount of the molecules in the SPR/MIP chips. The integration of micropumps and microvalves can automate the sample introduction process and precisely control the amount of the sample injection to the microfluidic system. The proposed biochip enables the label-free biosensing of biomolecules in an automatic format, and provides a highly sensitive, highly specific and high-throughput detection performance. Three samples, i.e. progesterone, cholesterol and testosterone, are successfully detected using the developed system. The experimental results show that the proposed SPR/MIP microfluidic chip provides a comparable sensitivity to that of large-scale SPR techniques, but with reduced sample consumption and an automatic format. As such, the developed biochip has significant potential for a wide variety of nanoscale biosensing applications. The preliminary results of the current paper were presented at Transducers 2005, Seoul, Korea, 5-9 June 2005.
Institute for Genomics and Systems Biology
Institute for Genomics and Systems Biology Discover. Predict. Improve. Advancing Human and , 2015 See all Research Papers Featured Video Introduction to Systems Biology Video: Introduction to Systems Biology News Jack Gilbert Heading UChicago Startup that Aims to Predict Behavior of Trillions of
Hunter, Margaret E.; Nico, Leo G.
2015-01-01
Invasive Asian Black Carp (Mylopharyngodon piceus) have been present in USA aquaculture facilities since the 1980s and wild Black Carp have been found in the Mississippi River Basin since the early 1990s. This study characterizes the genetic diversity and relatedness of the Basin’s Black Carp and clarifies the introduction history. Analyses focused on three mitochondrial markers (control region, cytochrome-b, and 16S) and seven nuclear microsatellite markers (nDNA), using aquaculture and wild-caught samples collected in the upper and lower Mississippi Basin. Of the three mitochondrial haplotypes, two were shared between the aquaculture and wild populations, while a third was only present in upper Mississippi wild-caught specimens. Due to the presence of diploid and triploid fish, microsatellite markers were scored as pseudodominant and revealed low polymorphism (NA = 4.6, NA Ave = 1.5). Nuclear Bayesian clustering analyses identified two genetically distinct groups and four subclusters, each primarily composed of a unique haplotype. Samples from three aquaculture farms were assigned to group 1, while a fourth farm included samples from both groups 1 and 2. Wild-caught fish from the upper Basin were predominantly group 1, whereas wild samples from the lower Mississippi were assigned to both genetic groups. The presence of divergent haplotypes and distinct nDNA groups, along with geographic distribution patterns, indicate that wild populations in the basin likely resulted from multiple introductions. Genetic similarities between wild and captive populations support claims that aquaculture is the introduction source, but a shortage of samples and a history of repeated transfers among facilities obscure the precise pathway.
Mueller-Doblies, Doris; Carrique-Mas, Juan J; Davies, Robert H
2014-01-01
In this descriptive study, the dynamics of Salmonella infection of turkey flocks were investigated by repeated sampling of houses where Salmonella had been identified. The aim of the study was to identify the most common scenarios involved in elimination, persistence and introduction of Salmonella in the different branches of the turkey industry. Sixty-two houses on 34 turkey farms (comprising breeding, rearing and finishing farms) were sampled longitudinally, starting with the identification of a positive flock. A total of 117 follow-on flocks were tested and cleaning and disinfection (C&D) was assessed during 66 post-C&D visits. A total of 155 incidents (clearance, persistence or introduction of Salmonella) were recorded. Persistence was seen in 35.5% of incidents and was seen more frequently in breeding and rearing houses compared with finishing houses. Most persistence incidents were the result of insufficient C&D. Clearance was seen in 40% of incidents and was more often observed in finishing houses than in breeding or rearing houses. Introduction was seen in 24.5% of incidents and was more common in breeding and finishing flocks than in rearing flocks. Contamination of a house with Salmonella Typhimurium was more likely to be cleared compared with other serovars. The total number of positive samples found at a post-C&D visit was correlated with the probability of carry-over of infection, whereas the location of the positive samples seemed to be less important. Our highly sensitive post-C&D sampling method allowed us to predict a negative follow-on flock in most cases.
2010-09-01
OF CONTENTS I. INTRODUCTION ............................................................................................. 1 A. BACKGROUND...PROBLEM DEFINITION............................................................................... 11 A. INTRODUCTION ...27 III. REQUIREMENTS DEVELOPMENT ............................................................. 29 A. INTRODUCTION
1979-12-01
capabilities that are not essential to routine support of the majority of Air Force training. TABLE OF CONTENTS PAGE 1.0 INTRODUCTION ...66 APPEINDIX A Listing of All Survey Items ---------------------- 67 APPENDIX B Introduction to Survey Form and...5 6 1.0 INTRODUCTION Prototype computer-based individualized training systems have been developed and implemented at a number of
Reconstructed plutonium fallout in the GV7 firn core from Northern Victoria Land, East Antarctica
NASA Astrophysics Data System (ADS)
Hwang, H.; Han, Y.; Kang, J.; Lee, K.; Hong, S.; Hur, S. D.; Narcisi, B.; Frezzotti, M.
2017-12-01
Atmospheric nuclear explosions during the period from the 1940s to the 1980s are the major anthropogenic source of plutonium (Pu) in the environment. In this work, we analyzed fg g-1 levels of artificial Pu, released predominantly by atmospheric nuclear weapons tests. We measured 351 samples which collected a 78 m-depth fire core at the site of GV7 (S 70°41'17.1", E 158°51'48.9", 1950 m a.s.l.), Northern Victoria Land, East Antarctica. To determine the Pu concentration in the samples, we used an inductively coupled plasma sector field mass spectrometry coupled with an Apex high-efficiency sample introduction system, which has the advantages of small sample consumption and simple sample preparation. We reconstructed the firn core Pu fallout record for the period after 1954 CE shows a significant fluctuation in agreement with past atmospheric nuclear testing. These data will contribute to ice core research by providing depth-age information.
75 FR 14057 - Federal Acquisition Regulation; Federal Acquisition Circular 2005-40; Introduction
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-23
...: Introduction, Small Entity Compliance Guide, Federal Awardee Performance and Integrity, Information System...; Federal Acquisition Circular 2005-40; Introduction AGENCIES: Department of Defense (DoD), General Services...
Assessing an Introduction to Systems Thinking
ERIC Educational Resources Information Center
Monroe, Martha C.; Plate, Richard R.; Colley, Lara
2015-01-01
This research study investigated the learning outcomes of a brief systems thinking intervention at the undergraduate level. A pre/post experimental design (n = 50) was used to address two primary questions: (1) Can a brief introduction to systems thinking improve students' understanding of systems thinking? and (2) Which teaching method (of…
Boulyga, Sergei F; Heilmann, Jens; Heumann, Klaus G
2005-08-01
Inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with direct laser-assisted introduction of isotope-diluted samples into the plasma, using a laser ablation system with high ablation rates, was developed for accurate sulfur determinations in different petroleum products such as 'sulfur-free' premium gasoline, diesel fuel, and heating oil. Two certified gas oil reference materials were analyzed for method validation. Two different 34S-enriched spike compounds, namely, elementary sulfur dissolved in xylene and dibenzothiophene in hexane, were synthesized and tested for their usefulness in this isotope dilution technique. The isotope-diluted sample was adsorbed on a filter-paper-like material, which was fixed in a special holder for irradiation by the laser beam. Under these conditions no time-dependent spike/analyte fractionation was only observed for the dibenzothiophene spike during the laser ablation process, which means that the measured 34S/32S isotope ratio of the isotope-diluted sample remained constant-a necessary precondition for accurate results with the isotope dilution technique. A comparison of LA-ICP-IDMS results with the certified values of the gas oil reference materials and with results obtained from ICP-IDMS analyses with wet sample digestion demonstrated the accuracy of the new LA-ICP-IDMS method in the concentration range of 9.2 microg g(-1) ('sulfur-free' premium gasoline) to 10.4 mg g(-1) (gas oil reference material BCR 107). The detection limit for sulfur by LA-ICP-IDMS is 0.04 microg g(-1) and the analysis time is only about 10 min, which therefore also qualifies this method for accurate determinations of low sulfur contents in petroleum products on a routine level.
Technology Transfer Opportunities: Automated Ground-Water Monitoring, A Proven Technology
Smith, Kirk P.; Granato, Gregory E.
1998-01-01
Introduction The U.S. Geological Survey (USGS) has developed and tested an automated ground-water monitoring system that measures and records values of selected water-quality properties and constituents using protocols approved for manual sampling. Prototypes using the automated process have demonstrated the ability to increase the quantity and quality of data collected and have shown the potential for reducing labor and material costs for ground-water quality data collection. Automated ground-water monitoring systems can be used to monitor known or potential contaminant sites, such as near landfills, underground storage tanks, or other facilities where potential contaminants are stored, to serve as early warning systems monitoring ground-water quality near public water-supply wells, and for ground-water quality research.
Reference pricing system and competition: case study from Portugal.
Portela, Conceiçăo
2009-10-01
To characterize the patterns of competition for a sample of drugs in the Portuguese pharmaceutical market before (January 2002-March 2003) and after (April 2003-June 2003) the introduction of the reference pricing system (RPS). We performed a descriptive, retrospective, longitudinal analysis, with monthly observations from January 2002 until June 2003 of 15 homogeneous groups. The groups represented the upper limit of public pharmaceutical expenditure in the RPS segment in 2003 (n=270). Measures of competition were: 1) number of presentations; 2) prescriptions' concentration in the generic and originator (brand) segments, using Herfindahl-Hirschman Index (HHI); and 3) dominant positions of market leader in the homogeneous group. A correlation analysis between the number of presentations, the HHI, and the dominant position of the market leader was performed using Pearson coefficient of correlation. The structure of the market changed with the introduction of RPS. We found an increasing number of generic presentations (from 4+/-3 to 7+/-4; mean+/-standard deviation) and a decrease in the HHI for the generics market segment (from 0.7+/-0.2 to 0.6+/-0.3). There was a negative correlation between those variables that increased after the introduction of RPS (from -0.6 to -0.8). The HHI for brands and the dominant positions remained unchanged. After the implementation of RPS, the increased competition was mainly driven by economic and social agents in the generics market segment but not in the brands market segment.
Nuclear Enterprise Performance Measurement
2011-03-01
xi I. Introduction ...WSA: Weapons Storage Area 1 I. Introduction Overview This paper discusses United States Air Force nuclear enterprise...sustainment systems. Keywords Performance measurement, process measurement, strategy, multicriteria decision- making, aggregation 1. Introduction Nuclear
High-throughput diagnosis of potato cyst nematodes in soil samples.
Reid, Alex; Evans, Fiona; Mulholland, Vincent; Cole, Yvonne; Pickup, Jon
2015-01-01
Potato cyst nematode (PCN) is a damaging soilborne pest of potatoes which can cause major crop losses. In 2010, a new European Union directive (2007/33/EC) on the control of PCN came into force. Under the new directive, seed potatoes can only be planted on land which has been found to be free from PCN infestation following an official soil test. A major consequence of the new directive was the introduction of a new harmonized soil sampling rate resulting in a threefold increase in the number of samples requiring testing. To manage this increase with the same staffing resources, we have replaced the traditional diagnostic methods. A system has been developed for the processing of soil samples, extraction of DNA from float material, and detection of PCN by high-throughput real-time PCR. Approximately 17,000 samples are analyzed each year using this method. This chapter describes the high-throughput processes for the production of float material from soil samples, DNA extraction from the entire float, and subsequent detection and identification of PCN within these samples.
Outbreak of legionnaires' disease from a cooling water system in a power station.
Morton, S; Bartlett, C L; Bibby, L F; Hutchinson, D N; Dyer, J V; Dennis, P J
1986-09-01
In September and October 1981 six cases of pneumonia occurred among men working in a power station under construction. Three were identified as cases of legionella pneumonia and two others had serology suggestive of legionella infection. In a sample of 92 men from the site 10 had low levels of antibodies to legionella; a similar sample of men working on an adjacent site showed none with positive serology. In a case control study it was found that cases of pneumonia were more likely than controls to have worked on a part of the site where four small capacity cooling towers were located. Legionella pneumophila serogroup 1 was isolated from the water systems of these four towers but was not found in samples from any other cooling towers or hot or cold water outlets on the site. It would appear that there was airborne spread of the organism from these cooling water systems which had not received conventional treatment to inhibit corrosion and organic growth. This is the first outbreak of legionnaires' disease to be recorded in an industrial setting in the United Kingdom. No cases of legionella infection have occurred on the site since the introduction of control measures.
Advanced Control Systems for Aircraft Powerplants
1980-02-01
production of high- integrity software. 1.0 INTRODUCTION Work on full-authority digital control for gas turbines was started at Rolls- Royce Limited... INTRODUCTION In order to fully understand the operation of the Secondary Power System Control Unit - abbreviated SPSCU - we must first take a close look at...Only Memory EPROM -- Erasable Read Only Memory PLA -- Power Lever Angle LVDT -- Linear Variable Differential Transformer INTRODUCTION Preliminary design
Advanced electronics for the CTF MEG system.
McCubbin, J; Vrba, J; Spear, P; McKenzie, D; Willis, R; Loewen, R; Robinson, S E; Fife, A A
2004-11-30
Development of the CTF MEG system has been advanced with the introduction of a computer processing cluster between the data acquisition electronics and the host computer. The advent of fast processors, memory, and network interfaces has made this innovation feasible for large data streams at high sampling rates. We have implemented tasks including anti-alias filter, sample rate decimation, higher gradient balancing, crosstalk correction, and optional filters with a cluster consisting of 4 dual Intel Xeon processors operating on up to 275 channel MEG systems at 12 kHz sample rate. The architecture is expandable with additional processors to implement advanced processing tasks which may include e.g., continuous head localization/motion correction, optional display filters, coherence calculations, or real time synthetic channels (via beamformer). We also describe an electronics configuration upgrade to provide operator console access to the peripheral interface features such as analog signal and trigger I/O. This allows remote location of the acoustically noisy electronics cabinet and fitting of the cabinet with doors for improved EMI shielding. Finally, we present the latest performance results available for the CTF 275 channel MEG system including an unshielded SEF (median nerve electrical stimulation) measurement enhanced by application of an adaptive beamformer technique (SAM) which allows recognition of the nominal 20-ms response in the unaveraged signal.
Cacho, J I; Campillo, N; Viñas, P; Hernández-Córdoba, M
2018-07-20
Nine organophosphorus pesticides (OPPs) were determined in environmental waters from different origins using in situ ionic liquid dispersive liquid microextraction (IL-DLLME). This preconcentration technique was coupled to gas chromatography-mass spectrometry (GC-MS) using microvial insert thermal desorption, an approach that uses a thermal desorption injector as sample introduction system. The parameters affecting both the microextraction and sample injection steps were optimized. The proposed method showed good precision, with RSD values ranging from 4.1 to 9.7%, accuracy with recoveries in the 85-118% range, and sensitivity with DLs ranging from 5 to 16 ng L -1 . Copyright © 2017 Elsevier B.V. All rights reserved.
Novel Acoustic Loading of a Mass Spectrometer: Toward Next-Generation High-Throughput MS Screening.
Sinclair, Ian; Stearns, Rick; Pringle, Steven; Wingfield, Jonathan; Datwani, Sammy; Hall, Eric; Ghislain, Luke; Majlof, Lars; Bachman, Martin
2016-02-01
High-throughput, direct measurement of substrate-to-product conversion by label-free detection, without the need for engineered substrates or secondary assays, could be considered the "holy grail" of drug discovery screening. Mass spectrometry (MS) has the potential to be part of this ultimate screening solution, but is constrained by the limitations of existing MS sample introduction modes that cannot meet the throughput requirements of high-throughput screening (HTS). Here we report data from a prototype system (Echo-MS) that uses acoustic droplet ejection (ADE) to transfer femtoliter-scale droplets in a rapid, precise, and accurate fashion directly into the MS. The acoustic source can load samples into the MS from a microtiter plate at a rate of up to three samples per second. The resulting MS signal displays a very sharp attack profile and ions are detected within 50 ms of activation of the acoustic transducer. Additionally, we show that the system is capable of generating multiply charged ion species from simple peptides and large proteins. The combination of high speed and low sample volume has significant potential within not only drug discovery, but also other areas of the industry. © 2015 Society for Laboratory Automation and Screening.
[Quality Management System in Pathological Laboratory].
Koyatsu, Junichi; Ueda, Yoshihiko
2015-07-01
Even compared to other clinical laboratories, the pathological laboratory conducts troublesome work, and many of the work processes are also manual. Therefore, the introduction of the systematic management of administration is necessary. It will be a shortcut to use existing standards such as ISO 15189 for this purpose. There is no standard specialized for the pathological laboratory, but it is considered to be important to a pathological laboratory in particular. 1. Safety nianagement of the personnel and environmental conditions. Comply with laws and regulations concerning the handling of hazardous materials. 2. Pre-examination processes. The laboratory shall have documented procedures for the proper collection and handling of primary samples. Developed and documented criteria for acceptance or rejection of samples are applied. 3. Examination processes. Selection, verification, and validation of the examination procedures. Devise a system that can constantly monitor the traceability of the sample. 4. Post-examination processes. Storage, retention, and disposal of clinical samples. 5. Release of results. When examination results fall within established alert or critical intervals, immediately notify the physicians. The important point is to recognize the needs of the client and be aware that pathological diagnoses are always "the final diagnoses".
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, L.T.
Because it has been our goal to interface the supercritical fluid chromatograph with a Fourier transform infrared spectrometer we have initially chosen packed columns due to their increased sample capacities, and supercritical CO/sub 2/ because of its infrared transparency. This paper compares two sampling techniques that can be utilized in packed column supercritical fluid Chromatography (SFC). Traditional sample introduction is accomplished using an injector with a sample loop. The loop is filled with the appropriate amount of material, and subsequently inserted into the mobile phase path. In most cases the sample must be either dissolved or extracted into an appropriatemore » solvent for such sample introduction. Note that unlike HPLC, where the solvent can be the same as the mobile phase, traditional sampling with SFC must use a solvent that is very different from the mobile phase. As a result, solvent peaks are almost always present, especially with universal detectors like FTIR. An alternative method is described here whereby both extraction of the sample and introduction of the extract onto the column is accomplished on-line using only the supercritical fluid mobile phase. This sampling technique is made possible by a simple valving scheme which ties directly the extraction vessel, the injector, the packed column and the detector. This technique has several advantages over the traditional methods, not the least of which is the absence of a large amount of foreign solvent introduced on the column. 11 refs., 7 figs.« less
Han, Jung Mi; Boo, Eun Hee; Kim, Jung A; Yoon, Soo Jin; Kim, Seong Woo
2012-01-01
Objectives This study evaluated the qualitative and quantitative performances of the newly developed information system which was implemented on November 4, 2011 at the National Health Insurance Corporation Ilsan Hospital. Methods Registration waiting time and changes in the satisfaction scores for the key performance indicators (KPI) before and after the introduction of the system were compared; and the economic effects of the system were analyzed by using the information economics approach. Results After the introduction of the system, the waiting time for registration was reduced by 20%, and the waiting time at the internal medicine department was reduced by 15%. The benefit-to-cost ratio was increased to 1.34 when all intangible benefits were included in the economic analysis. Conclusions The economic impact and target satisfaction rates increased due to the introduction of the new system. The results were proven by the quantitative and qualitative analyses carried out in this study. This study was conducted only seven months after the introduction of the system. As such, a follow-up study should be carried out in the future when the system stabilizes. PMID:23115744
Barrera, Chloe M; Hamner, Heather C; Perrine, Cria G; Scanlon, Kelley S
2018-03-01
Although there has been inconsistency in recommendations regarding the optimal time for introducing complementary foods, most experts agree that introduction should not occur before 4 months. Despite recommendations, studies suggest that 20% to 40% of US infants are introduced to foods at younger than 4 months. Previous studies focused on the introduction of solid foods and are not nationally representative. Our aims were to provide a nationally representative estimate of the timing of introduction of complementary foods and to describe predictors of early (<4 months) introduction. We conducted a cross-sectional analysis of 2009-2014 National Health and Nutrition Examination Survey data. The study included 1,482 children aged 6 to 36 months. Timing of first introduction to complementary foods (anything other than breast milk or formula) was analyzed. Prevalence estimates of first introduction to complementary foods are presented by month. Logistic regression was used to assess characteristics associated with early (<4 months) introduction. In this sample, 16.3% of US infants were introduced to complementary foods at <4 months, 38.3% between 4 and <6 months, 32.5% between 6 and <7 months, and 12.9% at ≥7 months of age. In unadjusted analyses, early introduction varied by breastfeeding status; race/Hispanic origin; Special Supplemental Nutrition Program for Women, Infants, and Children participation; and maternal age. In adjusted analyses, only breastfeeding status remained significant; infants who never breastfed or stopped at <4 months were more likely (odds ratio 2.27; 95% CI 1.62 to 3.18) to be introduced to complementary foods early than infants who breastfed ≥4 months. Despite using a broader definition of complementary foods, this analysis found a lower prevalence of early introduction in this nationally representative sample than previous studies that included only solids. However, many young children were still introduced to complementary foods earlier than recommended. Strategies to support caregivers to adhere to infant feeding guidelines may be needed. Copyright © 2018 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.
Analysis system for characterisation of simple, low-cost microfluidic components
NASA Astrophysics Data System (ADS)
Smith, Suzanne; Naidoo, Thegaran; Nxumalo, Zandile; Land, Kevin; Davies, Emlyn; Fourie, Louis; Marais, Philip; Roux, Pieter
2014-06-01
There is an inherent trade-off between cost and operational integrity of microfluidic components, especially when intended for use in point-of-care devices. We present an analysis system developed to characterise microfluidic components for performing blood cell counting, enabling the balance between function and cost to be established quantitatively. Microfluidic components for sample and reagent introduction, mixing and dispensing of fluids were investigated. A simple inlet port plugging mechanism is used to introduce and dispense a sample of blood, while a reagent is released into the microfluidic system through compression and bursting of a blister pack. Mixing and dispensing of the sample and reagent are facilitated via air actuation. For these microfluidic components to be implemented successfully, a number of aspects need to be characterised for development of an integrated point-of-care device design. The functional components were measured using a microfluidic component analysis system established in-house. Experiments were carried out to determine: 1. the force and speed requirements for sample inlet port plugging and blister pack compression and release using two linear actuators and load cells for plugging the inlet port, compressing the blister pack, and subsequently measuring the resulting forces exerted, 2. the accuracy and repeatability of total volumes of sample and reagent dispensed, and 3. the degree of mixing and dispensing uniformity of the sample and reagent for cell counting analysis. A programmable syringe pump was used for air actuation to facilitate mixing and dispensing of the sample and reagent. Two high speed cameras formed part of the analysis system and allowed for visualisation of the fluidic operations within the microfluidic device. Additional quantitative measures such as microscopy were also used to assess mixing and dilution accuracy, as well as uniformity of fluid dispensing - all of which are important requirements towards the successful implementation of a blood cell counting system.
NASA Astrophysics Data System (ADS)
Huang, Fan-Feng; Jiang, Shiuh-Jen; Chen, Yen-Ling; Sahayam, A. C.
2018-02-01
This paper describes a flow injection vapor generation (VG) method using inductively coupled plasma mass spectrometry (ICP-MS) for determining As, Cd, Sb, Hg, and Pb in nail polish. The samples for VG were prepared as aqueous slurries of a nail polish (0.5% m/v), thiourea (1% m/v), Co(II) (0.75 μg mL- 1), and HCl (1.2% v/v). Chemical VG of As, Cd, Sb, Hg, and Pb ions, by reduction with tetrahydroborate (3% m/v in 0.2% m/v NaOH), enabled their separation from the slurry. With VG sample introduction, As, Cd, Sb and Hg signals were increased by 1-2 orders (except Pb) compared to solution nebulization due to better sample introduction. Quantifications were performed by VG ICP-MS using isotope dilution and standard addition methods as slopes of calibration plots of analytes in the slurries were higher. Using the reported procedure, samples of three nail polishes purchased locally were analyzed for their levels of As, Cd, Sb, Hg, and Pb. The results obtained were in good agreement with those measured using electrothermal vaporization ICP-MS. In the original nail polish sample, the detection limits, calculated as 3σ of blank measurements, for As, Cd, Sb, Hg, and Pb, estimated from standard addition curves, were 0.06, 0.12, 0.14, 0.2, and 12 ng g- 1, respectively.
Overview of chemical imaging methods to address biological questions.
da Cunha, Marcel Menezes Lyra; Trepout, Sylvain; Messaoudi, Cédric; Wu, Ting-Di; Ortega, Richard; Guerquin-Kern, Jean-Luc; Marco, Sergio
2016-05-01
Chemical imaging offers extensive possibilities for better understanding of biological systems by allowing the identification of chemical components at the tissue, cellular, and subcellular levels. In this review, we introduce modern methods for chemical imaging that can be applied to biological samples. This work is mainly addressed to the biological sciences community and includes the bases of different technologies, some examples of its application, as well as an introduction to approaches on combining multimodal data. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Callefi, Luciana Azevedo; Medeiros, Eduardo Alexandrino Servolo de; Furtado, Guilherme Henrique Campos
2013-01-01
Enterobacteriaceae strains are a leading cause of bloodstream infections (BSI). The aim of this study is to assess differences in clinical outcomes of patients with BSI caused by Enterobacteriaceae strains before and after introduction of an automated microbiologic system by the microbiology laboratory. We conducted a retrospective cohort study aimed to evaluate the impact of the introduction of an automated microbiologic system (Phoenix(tm) automated microbiology system, Becton, Dickinson and Company (BD) - Diagnostic Systems, Sparks, MD, USA) on the outcomes of BSIs caused by Enterobacteriaceae strains. The study was undertaken at Hospital São Paulo, a 750-bed teaching hospital in São Paulo, Brazil. Patients with BSI caused by Enterobacteriaceae strains before the introduction of the automated system were compared with patients with BSI caused by the same pathogens after the introduction of the automated system with regard to treatment adequacy, clinical cure/improvement and 14- and 28-day mortality rates. We evaluated 90 and 106 patients in the non-automated and automated testing periods, respectively. The most prevalent species in both periods were Klebsiella spp. and Proteus spp. Clinical cure/improvement occurred in 70% and 67.9% in non-automated and automated period, respectively (p = 0.75). 14-day mortality rates were 22.2% and 30% (p = 0.94) and 28-day mortality rates were 24.5% and 40.5% (p = 0.12). There were no significant differences between the two testing periods with regard to treatment adequacy, clinical cure/improvement and 14- and 28-day mortality rates. Introduction of the BD Phoenix(tm) automated microbiology system did not impact the clinical outcomes of BSIs caused by Enterobacteriaceae strains in our setting.
On estimation in k-tree sampling
Christoph Kleinn; Frantisek Vilcko
2007-01-01
The plot design known as k-tree sampling involves taking the k nearest trees from a selected sample point as sample trees. While this plot design is very practical and easily applied in the field for moderate values of k, unbiased estimation remains a problem. In this article, we give a brief introduction to the...
Age at Introduction to Solid Foods and Child Obesity at 6 Years.
Barrera, Chloe M; Perrine, Cria G; Li, Ruowei; Scanlon, Kelley S
2016-06-01
Epidemiological evidence suggests that timing of introduction of solid foods may be associated with subsequent obesity, and the association may vary by whether an infant is breastfed or formula-fed. We included 1181 infants who participated in the Infant Feeding Practices Study II (IFPS II) and the Year 6 Follow Up (Y6FU) study. Data from IFPS II were used to calculate the primary exposure and timing of solid food introduction (<4, 4-<6, and ≥6 months), and data from Y6FU were used to calculate the primary outcome and obesity at 6 years of age (BMI ≥95th percentile). We used multivariable logistic regression to assess the association between timing of the introduction of solids and obesity at 6 years and test whether this association was modified by breastfeeding duration (breastfed for 4 months vs. not). Prevalence of obesity in our sample was 12.0%. The odds of obesity was higher among infants introduced to solids <4 months compared to those introduced at 4-<6 months (odds ratio [OR] = 1.66; 95% CI, 1.15, 2.40) in unadjusted analysis; however, this relationship was no longer significant after adjustment for covariates (OR = 1.18; 95% CI, 0.79, 1.77). Introduction of solids ≥6 months was not associated with obesity. We found no interaction between breastfeeding duration and early solid food introduction and subsequent obesity. Timing of introduction of solid foods was not associated with child obesity at 6 years in this sample. Given the inconsistency in findings with other studies, further studies in larger populations may be needed.
The Greek Education System and Implications for the Turkish Education System
ERIC Educational Resources Information Center
Karabulut, Nuriye
2018-01-01
The purpose of the current study is to make a detailed introduction to the Greek education system and to compare it with the Turkish education system to come up with some implications for the latter. To this end, the literature was reviewed. A general introduction was made to Greece and its education system was examined considering its goals,…
Lee, Jinho; Park, Chibeom; Song, Intek; Koo, Jin Young; Yoon, Taekyung; Kim, Jun Sung; Choi, Hee Cheul
2018-05-16
In this paper, we report an efficient alkali metal doping system for organic single crystals. Our system employs an enhanced diffusion method for the introduction of alkali metal into organic single crystals by controlling the sample temperature to induce secondary thermal activation. Using this system, we achieved intercalation of potassium into picene single crystals with closed packed crystal structures. Using optical microscopy and Raman spectroscopy, we confirmed that the resulting samples were uniformly doped and became K 2 picene single crystal, while only parts of the crystal are doped and transformed into K 2 picene without secondary thermal activation. Moreover, using a customized electrical measurement system, the insulator-to-semiconductor transition of picene single crystals upon doping was confirmed by in situ electrical conductivity and ex situ temperature-dependent resistivity measurements. X-ray diffraction studies showed that potassium atoms were intercalated between molecular layers of picene, and doped samples did not show any KH- nor KOH-related peaks, indicating that picene molecules are retained without structural decomposition. During recent decades, tremendous efforts have been exerted to develop high-performance organic semiconductors and superconductors, whereas as little attention has been devoted to doped organic crystals. Our method will enable efficient alkali metal doping of organic crystals and will be a resource for future systematic studies on the electrical property changes of these organic crystals upon doping.
NASA Astrophysics Data System (ADS)
Mukhamatdinov, I.; Gafurov, M.; Kemalov, A.; Rodionov, A.; Mamin, G.; Fakhretdinov, P.
2018-05-01
Cationic surfactant (adhesion additive) «Adgezolin» has been developed. It is shown that introduction of «Adgezolin» into the oxidized bitumen increases the relative amount of asphaltenes and monocyclearomatic hydrocarbons. By means of electron paramagnetic resonance (EPR) it is demonstrated that the introduction of additive «Adgezolin» increases the number of paramagnetic «free» carbon radicals (FR) in the oxidized bitumen and decreases that in the unoxidized species. In both types of bitumen shift from the Lorentzian to Gaussian EPR lineshape of FR is obtained that could be connected with as an increase of the samples homogeneity. It is supposed that while in the oxygenated bitumens introduction of additives leads to the disaggregation of asphaltene-resins compounds, in the unoxidized samples the balance is shifted towards formation of di-radicals.
Financing a Career Information System.
ERIC Educational Resources Information Center
Franklin, Paul L.
This practical introduction and guide to the financing of a state-based system of career information is intended for policy makers and practitioners engaged in implementing career information services. Chapter 1 is an introduction to both career information systems and their financing with concentration on service fees as the base for attaining…
Friction coefficient of spruce pine on steel -- a note on lubricants
Charles W. McMillin; Truett J. Lemoine; Floyd G. Manwiller
1970-01-01
Generally, the introduction of water and ethanol increased the friction coefficient for ovendry samples but decreased the coeffecient when the samples were saturated. Octanoic acid decreased the coefficient when samples were wet. In the entire experiment, coefficients ranged from 0.14 to 0.78.
NASA Astrophysics Data System (ADS)
Chen, Chih-Shyue; Jiang, Shiuh-Jen
1996-12-01
A simple and very inexpensive in-situ nebulizer/hydride generator was used with inductively coupled plasma mass spectrometry (ICP-MS) for the determination of As, Sb, Bi and Hg in water samples. The application of hydride generation ICP-MS alleviated the sensitivity problem of As, Sb, Bi and Hg determinations encountered when the conventional pneumatic nebulizer was used for sample introduction. The sample was introduced by flow injection to minimize the deposition of solids on the sampling orifice. The elements in the sample were reduced to the lower oxidation states with L-cysteine before being injected into the hydride generation system. This method has a detection limit of 0.003, 0.003, 0.017 and 0.17 ng ml -1 for As, Bi, Sb and Hg, respectively. This method was applied to determine As, Sb, Bi and Hg in a CASS-3 nearshore seawater reference sample, a SLRS-2 riverine water reference sample and a tap water collected from National Sun Yat-Sen University. The concentrations of the elements were determined by standard addition method. The precision was better than 20% for most of the determinations.
Szymandera-Buszka, Krystyna; Hęś, Marzanna; Waszkowiak, Katarzyna; Jędrusek-Golińska, Anna
2014-01-01
The aim of the study was to determine the effect of pasteurisation and sterilization of model systems of minced chicken meat in the presence of low or high-oxidised pork lard, soy and sunflower oil, as well as casein hydrolysate and rosemary extract, on losses of thiamine in model systems. In the samples, the thiamine content was analysed periodically by thiochromium method, as well as rate of lipid oxidation based on measurement of peroxide value (PV) by iodometric method and p-anisidine value (AV) by spectrophotometric method. It was observed that the thiamine losses in model systems of minced chicken after pasteurisation (61-71%) were higher than after sterilization (57-67%). Introduction of high-oxidised fat increased the total thiamine losses both during thermal processing and storage of meat samples (to 23%). A strong relationship was established between thiamine losses and rate of fat oxidation. The lowest total thiamine losses were observed in the samples with low-oxidised pork lard. Antioxidant addition (rosemary extract or casein hydrolysate) into meat samples limited the thiamine losses. However, the effect depended on oxidation of fat that was mixed with meat. In the samples with low-oxidised fat, higher protective effect was found for rosemary extract (7-11%). In the samples with high-oxidised fat, casein hydrolysate was superior to rosemary extract (14%). In order to increase the stability of thiamine in pasteurized or sterilized meat products with fats, the influence of fat type and its oxidative stability should be taken under consideration. Moreover, the addition of rosemary extract or casein hydrolysate has impact on the thiamine losses since it slows down lipid oxidation to a significant extent.
42 CFR 493.1200 - Introduction.
Code of Federal Regulations, 2011 CFR
2011-10-01
... (that is, preanalytic, analytic, and postanalytic) as well as general laboratory systems. (b) The...) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Quality System for Nonwaived Testing § 493.1200 Introduction. (a) Each laboratory that performs nonwaived testing must establish and maintain written policies...
Beyond new vaccine introduction: the uptake of pneumococcal conjugate vaccine in the African Region.
Olayinka, Folake; Ewald, Leah; Steinglass, Robert
2017-01-01
The number of vaccines available to low-income countries has increased dramatically over the last decade. Overall infant immunization coverage in the WHO African region has stagnated in the past few years while countries' ability to maintain high immunization coverage rates following introduction of new vaccines has been uneven. This case study examines post-introduction coverage among African countries that introduced PCV between 2008 and 2013 and the factors affecting Pneumococcal Conjugate Vaccine (PCV) introduction. Nearly one-third of countries did not achieve 80% infant PCV3 coverage by two years post-introduction and 58% of countries experienced a decline in coverage between post introduction years two and four. Major factors affecting coverage rates included introduction without adequate preparation, insufficient supply chain capacity and management, poor communication between organizations and with the public, and data collection systems that were insufficient to meet information needs. Deliberately addressing these issues as well as longstanding weaknesses during new vaccine introduction can strengthen the immunization and broader health system. Further study is required to identify and address factors that affect maintenance of high coverage following introduction of new vaccines in the African region. Immunization with PCV is one of the most important interventions protecting against pneumonia, the second leading cause of death for children under five globally.
NASA Technical Reports Server (NTRS)
Seale, Michael D.; Madaras, Eric I.
2000-01-01
The introduction of new, advanced composite materials into aviation systems requires it thorough understanding of the long-term effects of combined thermal and mechanical loading. As part of a study to evaluate the effects of thermal-mechanical cycling, it guided acoustic (Lamb) wave measurement system was used to measure the bending and out-of-plane stiffness coefficients of composite laminates undergoing thermal-mechanical loading. The system uses a pulse/receive technique that excites an antisymmetric Lamb mode and measures the time-of-flight over a wide frequency range. Given the material density and plate thickness, the bending and out-of-plane shear stiffnesses are calculated from a reconstruction of the velocity dispersion curve. A series of 16 and 32-ply composite laminates were subjected to it thermal-mechanical loading profile in load frames equipped with special environmental chambers. The composite systems studied were it graphite fiber reinforced amorphous thermoplastic polyimide and it graphite fiber reinforced bismaleimide thermoset. The samples were exposed to both high and low temperature extremes its well as high and low strain profiles. The bending and out-of-plane stiffnesses for composite sample that have undergone over 6,000 cycles of thermal-mechanical loading are reported. The Lamb wave generated elastic stiffness results have shown decreases of up to 20% at 4,936 loading cycles for the graphite/thermoplastic samples and up to 64% at 4,706 loading cycles for the graphite/thermoset samples.
Analyses via automated mass spectrometry (MS/DS)
NASA Technical Reports Server (NTRS)
Koenig, T.
1985-01-01
New or improved uses of the Finnigan 4000 quadrupole mass spectrometer (MS) with its associated INCOS data system (DS) were investigated. The first phase involved an evaluative activity in which specific problems with miscalibration and gas chromatographic column conditioning were identified. This also revealed one solution to the problem of detection of substances not visible in the gas chromatography detection mode. A second phase was to seek useful applications of the direct inlet systems. This mode of sample introduction has not been previously utilized on the existing equipment and was successfully applied to the analysis of the components of TONOX 60/40 and in the thermal degradation products of some polymeric materials. Suggestions are made for improving and expanding the use of the MS/DS system in materials development and testing.
ERIC Educational Resources Information Center
Kogan, Steven M.; Wejnert, Cyprian; Chen, Yi-fu; Brody, Gene H.; Slater, LaTrina M.
2011-01-01
Obtaining representative samples from populations of emerging adults who do not attend college is challenging for researchers. This article introduces respondent-driven sampling (RDS), a method for obtaining representative samples of hard-to-reach but socially interconnected populations. RDS combines a prescribed method for chain referral with a…
In-situ chemical oxidation (ISCO) involves the introduction of a chemical oxidant into the subsurface for the purpose of transforming ground water contaminants into less toxic or harmless byproducts. Due to oxidant persistence, ground water samples collected at hazardous waste si...
USDA-ARS?s Scientific Manuscript database
Introduction: Salmonella and Campylobacter contamination of broiler carcass skin increases during feather removal. There are several methods for sampling carcasses including sponging or swabbing of skin surface and skin excision. It is unclear whether sponge sampling is adequate to remove bacteri...
USDA-ARS?s Scientific Manuscript database
Introduction: Salmonella and Campylobacter contamination of broiler carcass skin increases during feather removal. There are several methods for sampling carcasses including sponging or swabbing of skin surface and skin excision. It is unclear whether sponge sampling is adequate to remove bacteria f...
Microfluidic evaporator for on-chip sample concentration.
Casadevall i Solvas, Xavier; Turek, Vladimir; Prodromakis, Themistoklis; Edel, Joshua B
2012-10-21
We present a simple technique for the concentration of liquid samples in microfluidic devices applicable for single or multiple-phase configurations. The strategy consists of capturing the sample of interest within microfluidic traps and breaking its continuity by the introduction of a gas phase, which is also used to evaporate it.
A fractal approach to dynamic inference and distribution analysis
van Rooij, Marieke M. J. W.; Nash, Bertha A.; Rajaraman, Srinivasan; Holden, John G.
2013-01-01
Event-distributions inform scientists about the variability and dispersion of repeated measurements. This dispersion can be understood from a complex systems perspective, and quantified in terms of fractal geometry. The key premise is that a distribution's shape reveals information about the governing dynamics of the system that gave rise to the distribution. Two categories of characteristic dynamics are distinguished: additive systems governed by component-dominant dynamics and multiplicative or interdependent systems governed by interaction-dominant dynamics. A logic by which systems governed by interaction-dominant dynamics are expected to yield mixtures of lognormal and inverse power-law samples is discussed. These mixtures are described by a so-called cocktail model of response times derived from human cognitive performances. The overarching goals of this article are twofold: First, to offer readers an introduction to this theoretical perspective and second, to offer an overview of the related statistical methods. PMID:23372552
Research on self-propagating high temperature synthesis prepared ZrC-ZrB2 composite ceramic
NASA Astrophysics Data System (ADS)
Yong, Cheng; Xunjia, Su; Genliang, Hou; YaKun, Xing
2013-03-01
ZrC-ZrB2 composite ceramic material is prepared by self-propagating high temperature synthesis, using Zr powders, CrO2 powders and Al powders as raw materials. Samples are studied by XRD and SEM, the results show that: ZrC-ZrB2 composite ceramic is attained after self-propagating high-temperature reaction, with Zr+ B4C as the main reactive system, and which is added respectively different content (CrO3 + Al) system. The study finds that the ceramic composite products are mainly composed of ZrC and ZrB2 phase, and other subphase. Compared to the main reactive system composite ceramic, composite ceramic grains grow up obviously, after introduction of the highly exothermic system (CrO3 + Al) in the main reactive system, and with the gradual increase of the content (CrO3 + Al).
Introduction to Fuzzy Set Theory
NASA Technical Reports Server (NTRS)
Kosko, Bart
1990-01-01
An introduction to fuzzy set theory is described. Topics covered include: neural networks and fuzzy systems; the dynamical systems approach to machine intelligence; intelligent behavior as adaptive model-free estimation; fuzziness versus probability; fuzzy sets; the entropy-subsethood theorem; adaptive fuzzy systems for backing up a truck-and-trailer; product-space clustering with differential competitive learning; and adaptive fuzzy system for target tracking.
Computer-Based National Information Systems. Technology and Public Policy Issues.
ERIC Educational Resources Information Center
Congress of the U.S., Washington, DC. Office of Technology Assessment.
A general introduction to computer based national information systems, and the context and basis for future studies are provided in this report. Chapter One, the introduction, summarizes computers and information systems and their relation to society, the structure of information policy issues, and public policy issues. Chapter Two describes the…
Outline of the Solar System: Activities for elementary students
NASA Technical Reports Server (NTRS)
Hartsfield, J.; Sellers, M.
1990-01-01
An introduction to the solar system for the elementary school student is given. The introduction contains historical background, facts, and pertinent symbols concerning the sun, the nine major planets and their moons, and information about comets and asteroids. Aids to teaching are given, including a solar system crossword puzzle with answers.
An Introduction to Dynamic Systems and Feedback.
ERIC Educational Resources Information Center
Rabins, Michael J.
This introduction to dynamic systems is intended for freshman and sophomore students in engineering, physical science, or social science. Material has been class tested and has led to increased student interest in further work in systems analysis and operations research. Notes are written for the student and are self-contained. Material can be…
Blaser, Simon; Diem, Hanspeter; von Felten, Andreas; Gueuning, Morgan; Andreou, Michael; Boonham, Neil; Tomlinson, Jennifer; Müller, Pie; Utzinger, Jürg; Frey, Jürg E; Bühlmann, Andreas
2018-06-01
Rapid genetic on-site identification methods at points of entry, such as seaports and airports, have the potential to become important tools to prevent the introduction and spread of economically harmful pest species that are unintentionally transported by the global trade of plant commodities. This paper reports the development and evaluation of a loop-mediated isothermal amplification (LAMP)-based identification system to prevent introduction of the three most frequently encountered regulated quarantine insect species groups at Swiss borders, Bemisia tabaci, Thrips palmi and several regulated fruit flies of the genera Bactrocera and Zeugodacus. The LAMP primers were designed to target a fragment of the mitochondrial cytochrome c oxidase subunit I gene and were generated based on publicly available DNA sequences. Laboratory evaluations analysing 282 insect specimens suspected to be quarantine organisms revealed an overall test efficiency of 99%. Additional on-site evaluation at a point of entry using 37 specimens performed by plant health inspectors with minimal laboratory training resulted in an overall test efficiency of 95%. During both evaluation rounds, there were no false-positives and the observed false-negatives were attributable to human-induced manipulation errors. To overcome the possibility of accidental introduction of pests as a result of rare false-negative results, samples yielding negative results in the LAMP method were also subjected to DNA barcoding. Our LAMP assays reliably differentiated between the tested regulated and non-regulated insect species within <1 h. Hence, LAMP assays represent suitable tools for rapid on-site identification of harmful pests, which might facilitate an accelerated import control process for plant commodities. © 2018 The Authors. Pest Management Science published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry. © 2018 The Authors. Pest Management Science published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry.
DOT National Transportation Integrated Search
1993-04-01
Introduction of enhanced information systems into an operational environment requires reallocation of functions among those responsible for providing service. This study describes an effort to develop and apply a methodology to identify the types of ...
Comprehensive Digital Imaging Network Project At Georgetown University Hospital
NASA Astrophysics Data System (ADS)
Mun, Seong K.; Stauffer, Douglas; Zeman, Robert; Benson, Harold; Wang, Paul; Allman, Robert
1987-10-01
The radiology practice is going through rapid changes due to the introduction of state-of-the-art computed based technologies. For the last twenty years we have witnessed the introduction of many new medical diagnostic imaging systems such as x-ray computed tomo-graphy, digital subtraction angiography (DSA), computerized nuclear medicine, single pho-ton emission computed tomography (SPECT), positron emission tomography (PET) and more re-cently, computerized digital radiography and nuclear magnetic resonance imaging (MRI). Other than the imaging systems, there has been a steady introduction of computed based information systems for radiology departments and hospitals.
Sakurai, Hiroaki; Kanada, Yoshikiyo; Sugiura, Yoshito; Motoya, Ikuo; Yamada, Masayuki; Tomita, Masao; Naka, Toru; Teranishi, Toshio; Tanabe, Shigeo; Tsujimura, Toru; Okanishi, Tetsuo
2013-01-01
[Purpose] A major issue in physical/occupational therapist education is the improvement of students' clinical techniques. In this study, we introduced an education system using an Objective Structured Clinical Examination (OSCE), and made an attempt at standardization of its evaluation. [Subjects] The subjects were 227 students in the classes of 2008 to 2010 who enrolled at our university between 2004 and 2006, before the introduction of the education system using OSCE, and 221 students in the classes of 2011 to 2013 who enrolled between 2007 and 2009, after the introduction. [Methods] Performances in attitude and skills (performance in clinical training and OSCE) were compared between before and after the introduction of OSCE. OSCE results were compared between before and after clinical trainings at each OSCE Level; and the correlation of between performances in clinical training and OSCE was examined. [Results] Performances in OSCE and clinical training (attitude, skills) were improved by the introduction of the education system using OSCE, but no significant correlation was observed in the relationship between performances in OSCE and clinical training. [Conclusion] Further studies should be conducted aiming at the standardization of clinical skill evaluation in postgraduate education to establish an education system using OSCE. PMID:24259918
Evaluation of introduction scenarios for a broadband access network
NASA Astrophysics Data System (ADS)
Bocker, Geert-Jan; Cuthbert, Laurie; Gobbi, Roberta; Inch, Robert; Sara, Lini
1995-02-01
The provision of broadband services at a reasonable cost to residential and small business customers is one of the major challenges facing operators. The introduction of cost-effective systems considering the existing infrastructure is an important study. Within the RACE project 2024 Broadband Access Facilities, the economic and evolution aspects of different introduction scenarios of a broadband access system suitable for providing these services are investigated. This paper presents the final results of this study.
ERIC Educational Resources Information Center
Forbes, Norma; And Others
A 5-year study of the social and cognitive effects of the introduction of commercial and educational television on rural Alaskan children utilized a variety of social and cognitive measures given to both longitudinal and cross-sectional samples of grade-school children: in 1977, when no participating village received television; in 1979, when half…
Hyde, Terri B.; Dentz, Holly; Wang, Susan A.; Burchett, Helen E.; Mounier-Jack, Sandra; Mantel, Carsten F.
2015-01-01
We conducted a systematic review of the published literature to examine the impact of new vaccine introduction on countries’ immunization and broader health systems. Six publication databases were searched using 104 vaccine and health system-related search terms. The search yielded 15,795 unique articles dating from December 31, 1911 to September 29, 2010. Based on review of the title and abstract, 654 (4%) of these articles were found to be potentially relevant and were referred for full review. After full review, 130 articles were found to be relevant and included in the analysis. These articles represented vaccines introduced to protect against 10 different diseases (hepatitis A, hepatitis B, Haemophilus influenzae type b disease, human papilloma virus infection, influenza, Japanese encephalitis, meningococcal meningitis, Streptococcus pneumoniae disease, rotavirus diarrhea and typhoid), in various formulations and combinations. Most reviewed articles (97 [75%]) reported experiences in high-income countries. New vaccine introduction was most efficient when the vaccine was introduced into an existing delivery platform and when introduced in combination with a vaccine already in the routine childhood immunization schedule (i.e., as a combination vaccine). New vaccine introduction did not impact coverage of vaccines already included in the routine childhood immunization schedule. The need for increased cold chain capacity was frequently reported. New vaccines facilitated the introduction and widespread use of auto-disable syringes into the immunization and the broader health systems. The importance of training and education for health care workers and social mobilization was frequently noted. There was evidence in high-income countries that new vaccine introduction was associated with reduced health-care costs. Future evaluations of new vaccine introductions should include the systematic and objective assessment of the impacts on a country’s immunization system and broader health system, especially in lower-income countries. PMID:22940378
[Bologna process and higher health education in Europe].
Decsi, Tamás; Barakonyi, Károly
2006-08-27
Introduction of the two cycles (Bachelor/Master) system represents sensitive aspect of the implementation of the Bologna process into higher health education. The authors used the methods of evidence based medicine to analyse available documents on the implementation of the Bologna process into the education of health sciences. Electronic search in the closed MEDLINE and open Internet databases. Electronic data collection resulted in so-called country reports (n=47) and in professional statements (n=7) of health education bodies. Majority of the country reports (n=26) did not mention at all the peculiar position of health education within the Bologna process. Many country reports stated with (n=8) or without (n=9) explanation that health sciences should be excluded from the introduction of the two educational cycles system. Only 4 country reports discussed future conditions and possibilities of introducing the two cycles system into higher health education; the German country report definitely declared that the two cycles educational system may be introduced also into health education. The seven statements of professional health educational bodies (including an ad hoc committee of the Hungarian medical faculties) did not support the introduction of the two cycles system into health education. The low demand for health professionals with Bachelor (i.e. unfinished) degree was repeatedly mentioned as strong argument for not introducing the two cycles system into health education. It should be noted, however, that the process of introducing the two cycles system has began: recent survey of EUA (European University Association) indicates that in three countries (Denmark, Flanders and Switzerland) the introduction in under current discussion. Among the principles of the Bologna process, the introduction of the two cycles system has not gain acceptance in the higher health education in Europe. However, most documents firmly support the introduction of other elements of the Bologna process (comparable degrees, system of credits, promotion of mobility of students and tutors, quality control, life long learning).
Yu, Ping; Gandhidasan, Senthilkumar; Miller, Alexis A
2010-06-01
The experience of clinicians at two public hospitals in Sydney, Australia, with the introduction and use of an oncology information system (OIS) was examined to extract lessons to guide the introduction of clinical information systems in public hospitals. Semi-structured interviews were conducted with 12 of 15 radiation oncologists employed at the two hospitals. The personnel involved in the decision making process for the introduction of the system were contacted and their decision making process revisited. The transcribed data were analyzed using NVIVO software. Themes emerged included implementation strategies and practices, the radiation oncologists' current use and satisfaction with the OIS, project management and the impact of the OIS on clinical practice. The hospitals had contrasting experiences in their introduction and use of the OIS. Hospital A used the OIS in all aspects of clinical documentation. Its implementation was associated with strong advocacy by the Head of Department, input by a designated project manager, and use and development of the system by all staff, with timely training and support. With no vision of developing a paperless information system, Hospital B used the OIS only for booking and patient tracking. A departmental policy that data entry for the OIS was centrally undertaken by administrative staff distanced clinicians from the system. All the clinicians considered that the OIS should continuously evolve to meet changing clinical needs and departmental quality improvement initiatives. This case study indicates that critical factors for the successful introduction of clinical information systems into hospital environment were an initial clear vision to be paperless, strong clinical leadership and management at the departmental level, committed project management, and involvement of all staff, with appropriate training. Clinician engagement is essential for post-adoption evolution of clinical information systems. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.
Cost-Benefit Analysis of the Officer Career Information and Planning System
1980-08-01
information without the use of a computer. - vii COST-BENEFIT ANALYSIS OF THE OFFICER CAREER INFOýKATTON AND PLANNING SYSTEM CONTENTS Page INTRODUCTION ...OF THE OFFICER CAREER INFORMATION AND PLANNING SYSTEM INTRODUCTION The implementation of the Officer Personnel Management System (OPMS) has...Research Report 1256 I / COST-BENEFIT ANALYSIS OF THE OFFICER CAREER INFORMATION AND PLANNING SYSTEM Roger A. Myers, Peter C. Cairo, K - Jon A
Monitoring hydrilla using two RAPD procedures and the nonindigenous aquatic species database
Madeira, Paul T.; Jacono, C.C.; Van, Thai K.
2000-01-01
Hydrilla (Hydrilla verticillata (L.f.) Royle), an invasive aquatic weed, continues to spread to new regions in the United States. Two biotypes, one a female dioecious and the other monoecious have been identified. Management of the spread of hydrilla requires understanding the mechanisms of introduction and transport, an ability to map and make available information on distribution, and tools to distinguish the known U.S. biotypes as well as potential new introductions. Review of the literature and discussions with aquatic scientists and resource managers point to the aquarium and water garden plant trades as the primary past mechanism for the regional dispersal of hydrilla while local dispersal is primarily carried out by other mechanisms such as boat traffic, intentional introductions, and waterfowl. The Nonindigenous Aquatic Species (NAS) database is presented as a tool for assembling, geo-referencing, and making available information on the distribution of hydrilla. A map of the current range of dioecious and monoecious hydrilla by drainage is presented. Four hydrilla samples, taken from three discrete, non-contiguous regions (Pennsylvania, Connecticut, and Washington State) were examined using two RAPD assays. The first, generated using primer Operon G17, and capable of distinguishing the dioecious and monoecious U.S. biotypes, indicated all four samples were of the monoecious biotype. Results of the second assay using the Stoffel fragment and 5 primers, produced 111 markers, indicated that these samples do not represent new foreign introductions. The differences in the monoecious and dioecious growth habits and management are discussed.
Yanez, Laura A; Lucero, Noelia S; Barril, Patricia A; Díaz, María Del P; Tenaglia, María M; Spinsanti, Lorena I; Nates, Silvia V; Isa, María B; Ré, Viviana E
2014-01-01
Hepatitis A virus (HAV) has shown intermediate endemicity in Argentina, but notification of clinical cases has decreased since the introduction of the vaccine in 2005. In order to get insight into the local circulation of this virus after four years of the official introduction of the vaccine, the aims of this study were to provide information on HAV immune status of the adult population of Córdoba city and to conduct environmental surveillance of HAV in sewage and river samples in the same region. The prevalence of anti-HAV was determined by EIA in 416 samples of people (without prior vaccination) from Córdoba city (2009-2010). Spline regression models were estimated under generalized additive models. Environmental surveillance was conducted in river and sewage samples collected in the same period. Viral detection was performed by RT-Nested PCR of the 5'UTR. In Córdoba, the global prevalence of anti-HAV was 73.5%. It increased with age (p<0.0001) and it was associated with the low-income population (OR: 1.14; 95% CI 1.05-1.25). This prevalence decreased in younger age groups, especially in the high-income population. Environmental monitoring revealed the presence of HAV (IA) in 20.8% and 16.1% of wastewater and river samples, respectively. As a consequence of a decrease in HAV circulation due to improvements in immunization, socio-economic and hygienic conditions, young adults are becoming increasingly susceptible to HAV infections. Environmental monitoring demonstrated that HAV circulates in the local population; therefore, health care systems should consider the implementation of preventive measures for susceptible adults in order to reduce the risk of HAV infection. Copyright © 2013 Elsevier B.V. All rights reserved.
Tropical fish community does not recover 45 years after predator introduction.
Sharpe, D M T; De León, L F; González, R; Torchin, M E
2017-02-01
Predation is considered to be an important factor structuring natural communities. However, it is often difficult to determine how it may influence long-term, broad-scale, diversity patterns, particularly in diverse tropical systems. Biological introductions can provide powerful insight to test the sustained consequences of predation in natural communities, if pre-introduction data are available. Half a century ago, Zaret and Paine demonstrated strong and immediate community-level effects following the introduction of a novel apex predator (peacock bass, Cichla monoculus) into Lake Gatun, Panama. To test for long-term changes associated with this predator introduction, we followed up on their classic study by replicating historical sampling methods and examining changes in the littoral fish community at two sites in Lake Gatun 45 years post-introduction. To broaden our inference, we complemented this temporal comparison with a spatial analysis, wherein we compared the fish communities from two lakes with and one lake without peacock bass. Comparisons with historical data revealed that the peacock bass remains the most abundant predator in Lake Gatun. Furthermore, the collapse of the littoral prey community observed immediately following the invasion has been sustained over the past 45 years. The mean abundance of native littoral fish is now 96% lower than it was prior to the introduction. Diversity (rarefied species richness) declined by 64% post-introduction, and some native species appear to have been locally extirpated. We observed a similar pattern across invaded and uninvaded lakes: the mean abundance of native fishes was 5-40 times lower in lakes with (Gatun, Alajuela) relative to the lake without peacock bass (Bayano). In particular, small-bodied native fishes (Characidae, Peociliidae), which are common prey of the peacock bass, were more than two orders of magnitude (307 times) less abundant in Gatun and one order of magnitude (28 times) less abundant in Alajuela than in Bayano. However, total native fish diversity did not differ significantly across lakes, suggesting that while many native species have declined in abundance, few have been completely extirpated. Introduced predators can have strong effects on community structure and functional diversity, even in highly diverse tropical communities, and these effects can persist over multiple decades. © 2016 by the Ecological Society of America.
Elemental and isotopic imaging of biological samples using NanoSIMS.
Kilburn, Matt R; Clode, Peta L
2014-01-01
With its low detection limits and the ability to analyze most of the elements in the periodic table, secondary ion mass spectrometry (SIMS) represents one of the most versatile in situ analytical techniques available, and recent developments have resulted in significant advantages for the use of imaging mass spectrometry in biological and biomedical research. Increases in spatial resolution and sensitivity allow detailed interrogation of samples at relevant scales and chemical concentrations. Advances in dynamic SIMS, specifically with the advent of NanoSIMS, now allow the tracking of stable isotopes within biological systems at subcellular length scales, while static SIMS combines subcellular imaging with molecular identification. In this chapter, we present an introduction to the SIMS technique, with particular reference to NanoSIMS, and discuss its application in biological and biomedical research.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Introduction. 700.2 Section 700.2 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF... PRIORITIES AND ALLOCATIONS SYSTEM Overview § 700.2 Introduction. (a) Certain national defense and energy...
Cucurbit germplasm collections at the North Central Regional Plant Introduction Station
USDA-ARS?s Scientific Manuscript database
The North Central Regional Plant Introduction Station (NCRPIS) in Ames, Iowa, USA is one of four primary Plant Introduction Stations in the National Plant Germplasm System (NPGS), and has responsibility for maintenance, regeneration, characterization, and distribution of the NPGS Cucumis and Cucurbi...
Hartwell, H; Edwards, J S
2001-12-01
The goal of any hospital caterer should be to provide food that meets nutritional requirements, satisfies the patient, improves morale and is microbiologically safe. Food distribution to hospital wards plays a critical role. The aim of this study was to compare two hospital food service systems using parameters of food safety and consumer opinion. An NHS hospital was selected where food delivery was due to change from a plated system to a cafeteria trolley system. Samples (50 g) of dishes (n = 27) considered to be high-risk were collected for three consecutive days from breakfast, lunch and supper meals. The samples were taken from a pre-ordered tray (similar to that of a patient) in the plated system and from the trolley on the ward in the cafeteria system of meal delivery (approximately six months after its introduction). Consumer opinions cards (n = 180) were distributed and interviews also conducted. Microbiologically, the quality of food items delivered by both systems was satisfactory. However, concern was raised with the plated system, not for hot foods cooling down but for chilled foods warming up and being sustained in ambient conditions. Overall consumer satisfaction and experience was enhanced with the trolley system. Food was hotter and generally perceived to be of a better quality. Satisfaction with cold desserts was not dependent on the delivery system.
Machado, Raquel C; Amaral, Clarice D B; Nóbrega, Joaquim A; Araujo Nogueira, Ana Rita
2017-06-14
A microwave-induced plasma optical emission spectrometer with N 2 -based plasma was combined with a multimode sample introduction system (MSIS) for hydride generation (HG) and multielemental determination of As, Bi, Ge, Sb, and Sn in samples of forage, bovine liver, powdered milk, agricultural gypsum, rice, and mineral fertilizer, using a single condition of prereduction and reduction. The accuracy of the developed analytical method was evaluated using certified reference materials of water and mineral fertilizer, and recoveries ranged from 95 to 106%. Addition and recovery experiments were carried out, and the recoveries varied from 85 to 117% for all samples evaluated. The limits of detection for As, Bi, Ge, Sb, and Sn were 0.46, 0.09, 0.19, 0.46, and 5.2 μg/L, respectively, for liquid samples, and 0.18, 0.04, 0.08, 0.19, and 2.1 mg/kg, respectively, for solid samples. The method proposed offers a simple, fast, multielemental, and robust alternative for successful determination of all five analytes in agricultural samples with low operational cost without compromising analytical performance.
Spatially resolved δ13C analysis using laser ablation isotope ratio mass spectrometry
NASA Astrophysics Data System (ADS)
Moran, J.; Riha, K. M.; Nims, M. K.; Linley, T. J.; Hess, N. J.; Nico, P. S.
2014-12-01
Inherent geochemical, organic matter, and microbial heterogeneity over small spatial scales can complicate studies of carbon dynamics through soils. Stable isotope analysis has a strong history of helping track substrate turnover, delineate rhizosphere activity zones, and identifying transitions in vegetation cover, but most traditional isotope approaches are limited in spatial resolution by a combination of physical separation techniques (manual dissection) and IRMS instrument sensitivity. We coupled laser ablation sampling with isotope measurement via IRMS to enable spatially resolved analysis over solid surfaces. Once a targeted sample region is ablated the resulting particulates are entrained in a helium carrier gas and passed through a combustion reactor where carbon is converted to CO2. Cyrotrapping of the resulting CO2 enables a reduction in carrier gas flow which improves overall measurement sensitivity versus traditional, high flow sample introduction. Currently we are performing sample analysis at 50 μm resolution, require 65 ng C per analysis, and achieve measurement precision consistent with other continuous flow techniques. We will discuss applications of the laser ablation IRMS (LA-IRMS) system to microbial communities and fish ecology studies to demonstrate the merits of this technique and how similar analytical approaches can be transitioned to soil systems. Preliminary efforts at analyzing soil samples will be used to highlight strengths and limitations of the LA-IRMS approach, paying particular attention to sample preparation requirements, spatial resolution, sample analysis time, and the types of questions most conducive to analysis via LA-IRMS.
Method for detection of long-lived radioisotopes in small biochemical samples
Turteltaub, K.W.; Vogel, J.S.; Felton, J.S.; Gledhill, B.L.; Davis, J.C.
1994-11-22
Disclosed is a method for detection of long-lived radioisotopes in small biochemical samples, comprising: a. selecting a biological host in which radioisotopes are present in concentrations equal to or less than those in the ambient biosphere, b. preparing a long-lived radioisotope labeled reactive chemical specie, c. administering the chemical specie to the biologist host in doses sufficiently low to avoid significant overt damage to the biological system, d. allowing a period of time to elapse sufficient for dissemination and interaction of the chemical specie with the host throughout the biological system of the host, e. isolating a reacted fraction of the biological substance from the host in a manner sufficient to avoid contamination of the substance from extraneous sources, f. converting the fraction of biological substance by suitable means to a material which efficiently produces charged ions in at least one of several possible ion sources without introduction of significant isotopic fractionation, and, g. measuring the radioisotope concentration in the material by means of direct isotopic counting. 5 figs.
Thermally-actuated, phase change flow control for microfluidic systems.
Chen, Zongyuan; Wang, Jing; Qian, Shizhi; Bau, Haim H
2005-11-01
An easy to implement, thermally-actuated, noninvasive method for flow control in microfluidic devices is described. This technique takes advantage of the phase change of the working liquid itself-the freezing and melting of a portion of a liquid slug-to noninvasively close and open flow passages (referred to as a phase change valve). The valve was designed for use in a miniature diagnostic system for detecting pathogens in oral fluids at the point of care. The paper describes the modeling, construction, and characteristics of the valve. The experimental results favorably agree with theoretical predictions. In addition, the paper demonstrates the use of the phase change valves for flow control, sample metering and distribution into multiple analysis paths, sealing of a polymerase chain reaction (PCR) chamber, and sample introduction into and withdrawal from a closed loop. The phase change valve is electronically addressable, does not require any moving parts, introduces only minimal dead volume, is leakage and contamination free, and is biocompatible.
Method for detection of long-lived radioisotopes in small biochemical samples
Turteltaub, Kenneth W.; Vogel, John S.; Felton, James S.; Gledhill, Barton L.; Davis, Jay C.
1994-01-01
Disclosed is a method for detection of long-lived radioisotopes in small bio-chemical samples, comprising: a. selecting a biological host in which radioisotopes are present in concentrations equal to or less than those in the ambient biosphere, b. preparing a long-lived radioisotope labeled reactive chemical specie, c. administering said chemical specie to said biologist host in doses sufficiently low to avoid significant overt damage to the biological system thereof, d. allowing a period of time to elapse sufficient for dissemination and interaction of said chemical specie with said host throughout said biological system of said host, e. isolating a reacted fraction of the biological substance from said host in a manner sufficient to avoid contamination of said substance from extraneous sources, f. converting said fraction of biological substance by suitable means to a material which efficiently produces charged ions in at least one of several possible ion sources without introduction of significant isotopic fractionation, and, g. measuring the radioisotope concentration in said material by means of direct isotopic counting.
Towards an optimal flow: Density-of-states-informed replica-exchange simulations
Vogel, Thomas; Perez, Danny
2015-11-05
Here we learn that replica exchange (RE) is one of the most popular enhanced-sampling simulations technique in use today. Despite widespread successes, RE simulations can sometimes fail to converge in practical amounts of time, e.g., when sampling around phase transitions, or when a few hard-to-find configurations dominate the statistical averages. We introduce a generalized RE scheme, density-of-states-informed RE, that addresses some of these challenges. The key feature of our approach is to inform the simulation with readily available, but commonly unused, information on the density of states of the system as the RE simulation proceeds. This enables two improvements, namely,more » the introduction of resampling moves that actively move the system towards equilibrium and the continual adaptation of the optimal temperature set. As a consequence of these two innovations, we show that the configuration flow in temperature space is optimized and that the overall convergence of RE simulations can be dramatically accelerated.« less
Schneider, Florian R; Mann, Alexander B; Konorov, Igor; Delso, Gaspar; Paul, Stephan; Ziegler, Sibylle I
2012-06-01
A one-day laboratory course on positron emission tomography (PET) for the education of physics students and PhD students in medical physics has been set up. In the course, the physical background and the principles of a PET scanner are introduced. Course attendees set the system in operation, calibrate it using a (22)Na point source and reconstruct different source geometries filled with (18)F. The PET scanner features an individual channel read-out of 96 lutetium oxyorthosilicate (LSO) scintillator crystals coupled to avalanche photodiodes (APD). The analog data of each APD are digitized by fast sampling analog to digital converters (SADC) and processed within field programmable gate arrays (FPGA) to extract amplitudes and time stamps. All SADCs are continuously sampling with a precise rate of 80MHz, which is synchronous for the whole system. The data is transmitted via USB to a Linux PC, where further processing and the image reconstruction are performed. The course attendees get an insight into detector techniques, modern read-out electronics, data acquisition and PET image reconstruction. In addition, a short introduction to some common software applications used in particle and high energy physics is part of the course. Copyright © 2011. Published by Elsevier GmbH.
Recommendations for representative ballast water sampling
NASA Astrophysics Data System (ADS)
Gollasch, Stephan; David, Matej
2017-05-01
Until now, the purpose of ballast water sampling studies was predominantly limited to general scientific interest to determine the variety of species arriving in ballast water in a recipient port. Knowing the variety of species arriving in ballast water also contributes to the assessment of relative species introduction vector importance. Further, some sampling campaigns addressed awareness raising or the determination of organism numbers per water volume to evaluate the species introduction risk by analysing the propagule pressure of species. A new aspect of ballast water sampling, which this contribution addresses, is compliance monitoring and enforcement of ballast water management standards as set by, e.g., the IMO Ballast Water Management Convention. To achieve this, sampling methods which result in representative ballast water samples are essential. We recommend such methods based on practical tests conducted on two commercial vessels also considering results from our previous studies. The results show that different sampling approaches influence the results regarding viable organism concentrations in ballast water samples. It was observed that the sampling duration (i.e., length of the sampling process), timing (i.e., in which point in time of the discharge the sample is taken), the number of samples and the sampled water quantity are the main factors influencing the concentrations of viable organisms in a ballast water sample. Based on our findings we provide recommendations for representative ballast water sampling.
Specifications-Based Grading in an Introduction to Proofs Course
ERIC Educational Resources Information Center
Williams, Kristopher
2018-01-01
This article describes a system of specifications-based grading used in an introduction to proofs course. The system was introduced to address two issues that arose in the course: how to spend less time grading and how to encourage use of feedback. We describe the implementation of the system and the results on grading and on students.
1982-09-01
INTRODUCTION In the design of lightly armored vehicles it is of critical importance to be able to predict the vulnerability of these systems to...to similar geometry steel projectiles tested previously. INTRODUCTION The use of magnesium in proposed warhead designs has prompted renewed...to examine these excursions. INTRODUCTION The survival of a deeply buried missile capsule in a sand shaft was being evaluated during the
Erni, F; Frei, R W
1976-09-29
A device is described that makes use of an eight-port motor valve to generate step gradients on the low-pressure side of a piston pump with a low dead volume. Such a gradient device with an automatic control unit, which also permits repetition of previous steps, can be built for about half the cost of a gradient system with two pumps. Applications of this gradient unit to the separation of complex mixtures of glycosides and alkaloids are discussed and compared with separations systems using two high-pressure pumps. The gradients that are used on reversed-phase material with solvent mixtures of water and completely miscible organic solvents are suitable for quantitative routine control of pharmaceutical products. The reproducibility of retention data is excellent over several months and, with the use of loop injectors, major components can be determined quantitatively with a reproducibility of better than 2% (relative standard deviation). The step gradient selector valve can also be used as an introduction system for very large sample volumes. Up to 11 can be injected and samples with concentrations of less than 1 ppb can be determined with good reproducibilities.
NASA Astrophysics Data System (ADS)
Yasuhara, S.
2013-12-01
The ability to measure the isotopic composition of matrix-bound water is valuable to many facets of earth and environmental sciences. For example, ecohydrologists use stable isotopes of oxygen and hydrogen in plant and soil water, in combination with measurements of atmospheric water vapor, surface water and precipitation, to estimate budgets of evapotranspiration. Likewise, water isotopes of oceanic water, brines and other waters with high total dissolved solids (TDS, e.g., juices) are relevant to studying large-scale oceanic circulation, small-scale mixing, groundwater contamination, the balance of evaporation to precipitation, and the provenance of food. Conventionally matrix-bound water has been extracted using cryogenic distillation, whereby water is distilled from the material in question (e.g., a leaf sample) by heating under vacuum and collecting the resultant water vapor using liquid nitrogen. The water can then be analyzed for its stable isotopic composition by a variety of methods, including isotope ratio mass spectrometry and laser techniques, such as Cavity Ring-Down Spectroscopy (CRDS). Here we present recent improvements in an alternative, and stream-lined, solution for integrated sample extraction and isotopic measurement using a Picarro Induction Module (IM) coupled to commercially-available CRDS analyzer from Picarro. This technique is also valuable for waters with high TDS, which can have detrimental effects on flash vaporization process, typically used for the introduction of water to Picarro CRDS water isotope analyzers. The IM works by inductively heating a sample held within a metal sample holder in a glass vial flushed with dry air. Tested samples include leaves, stems, twigs, calibration water, juices, and salt water. The heating process evolves water vapor which is then swept through the system at approximately 150 standard cubic centimeters per minute. The evolved water vapor passes through an activated charcoal cartridge for removal of large organics, and then through Picarro's Micro-Combustion Cartridge that acts to oxidize interfering organics to CO2 and H2O. Using an open-split, the IM is interfaced directly with a CRDS system (in this case, an L2130-i) for the measurement of δ18O and δD. Based on replicate measurements of water introduced to the system using glass filter paper, the precision of the system is better than 0.35 and 1.5 ‰ for δ18O and δD, respectively. We will present improvements in system operation that have reduced systematic errors associated with (i) variable backgrounds, and (ii) exchange between the sample and the local atmosphere during sample introduction. In addition, we will present calibration data, and data demonstrating the effectiveness of the Micro-Combustion Cartridge at removing organics, which can result in spectroscopic interference. Finally, we will compare localized leaf water data against integrated whole leaf water data to demonstrate the added value of being able to sample small (approximately 5 mm diameter) areas of a leaf, and compare the results of measuring samples with high TDS on an IM and a Picarro High Precision Vaporizer.
Fujii, Yuji; Henares, Terence G; Kawamura, Kunio; Endo, Tatsuro; Hisamoto, Hideaki
2012-04-21
To enhance sensitivity and facilitate easy sample introduction into a combinable poly(dimethylsiloxane) (PDMS) capillary (CPC) sensor array, PDMS was modified in bulk and on its surface to prepare "black" PDMS coated with a silver layer and self-assembled monolayer (SAM). India ink, a traditional Japanese black ink, was added to the PDMS pre-polymer for bulk modification. The surface was modified by a silver mirror reaction followed by SAM formation using cysteine. These modifications enhanced the fluorescence signals by reflecting them from the surface and reducing background interference. A decrease in the water contact angle led to enhanced sensitivity and easy sample introduction. Furthermore, a CPC sensor array for multiplex detection of serum sample components was prepared that could quantify the analytes glucose, potassium, and alkaline phosphatase (ALP). When serum samples were introduced by capillary action, the CPC sensor array showed fluorescence responses for each analyte and successfully identified the components with elevated concentrations in the serum samples.
NASA Astrophysics Data System (ADS)
Syusina, O. M.; Chernitsov, A. M.; Tamarov, V. A.; Baturin, A. P.
2011-07-01
The analysis various systems of initial orbital elements of comet Herschel-Rigollet defined in bases on different sample of observations was given. In spite of slight quantity of first appearance observations the introduction of weighting coefficients and the new rejection algorithm is allowed to define the most precise system of orbital elements with the least value of volume confidence region.
Airport-Noise Levels and Annoyance Model (ALAMO) user's guide
NASA Technical Reports Server (NTRS)
Deloach, R.; Donaldson, J. L.; Johnson, M. J.
1986-01-01
A guide for the use of the Airport-Noise Level and Annoyance MOdel (ALAMO) at the Langley Research Center computer complex is provided. This document is divided into 5 primary sections, the introduction, the purpose of the model, and an in-depth description of the following subsystems: baseline, noise reduction simulation and track analysis. For each subsystem, the user is provided with a description of architecture, an explanation of subsystem use, sample results, and a case runner's check list. It is assumed that the user is familiar with the operations at the Langley Research Center (LaRC) computer complex, the Network Operating System (NOS 1.4) and CYBER Control Language. Incorporated within the ALAMO model is a census database system called SITE II.
Snidal, Sarah; Saidu, Yauba; Ojumu, Abiola; Ngatia, Antony; Bagana, Murtala; Mutuku, Faith; Sobngwi, Joelle; Efe-Aluta, Oniovo; Roper, Julia; LeTallec, Yann; Kang’ethe, Alice
2017-01-01
Abstract Introducing a new vaccine is a large-scale endeavor that can face many challenges, resulting in introduction delays and inefficiencies. The development of national task teams and tools, such as prelaunch trackers, for the introduction of new vaccines (hereafter, “new vaccine introductions” [NVIs]) can help countries implement robust project management systems, front-load critical preparatory activities, and ensure continuous communication around vaccine supply and financing. In addition, implementing postlaunch assessments to take rapid corrective action accelerates the uptake of the new vaccines. NVIs can provide an opportunity to strengthen routine immunization, through strengthening program management systems or by reinforcing local immunization managers’ abilities, among others. This article highlights key lessons learned during the introduction of inactivated poliovirus vaccine in 3 countries that would make future NVIs more successful. The article concludes by considering how the Immunization Systems Management Group of the Global Polio Eradication Initiative has been useful to the NVI process and how such global structures could be further enhanced. PMID:28838156
Fiuzy, Mohammad; Haddadnia, Javad; Mollania, Nasrin; Hashemian, Maryam; Hassanpour, Kazem
2012-01-01
Accurate Diagnosis of Breast Cancer is of prime importance. Fine Needle Aspiration test or "FNA", which has been used for several years in Europe, is a simple, inexpensive, noninvasive and accurate technique for detecting breast cancer. Expending the suitable features of the Fine Needle Aspiration results is the most important diagnostic problem in early stages of breast cancer. In this study, we introduced a new algorithm that can detect breast cancer based on combining artificial intelligent system and Fine Needle Aspiration (FNA). We studied the Features of Wisconsin Data Base Cancer which contained about 569 FNA test samples (212 patient samples (malignant) and 357 healthy samples (benign)). In this research, we combined Artificial Intelligence Approaches, such as Evolutionary Algorithm (EA) with Genetic Algorithm (GA), and also used Exact Classifier Systems (here by Fuzzy C-Means (FCM)) to separate malignant from benign samples. Furthermore, we examined artificial Neural Networks (NN) to identify the model and structure. This research proposed a new algorithm for an accurate diagnosis of breast cancer. According to Wisconsin Data Base Cancer (WDBC) data base, 62.75% of samples were benign, and 37.25% were malignant. After applying the proposed algorithm, we achieved high detection accuracy of about "96.579%" on 205 patients who were diagnosed as having breast cancer. It was found that the method had 93% sensitivity, 73% specialty, 65% positive predictive value, and 95% negative predictive value, respectively. If done by experts, Fine Needle Aspiration (FNA) can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples. FNA can be the first line of diagnosis in women with breast masses, at least in deprived regions, and may increase health standards and clinical supervision of patients. Such a smart, economical, non-invasive, rapid and accurate system can be introduced as a useful diagnostic system for comprehensive treatment of breast cancer. Another advantage of this method is the possibility of diagnosing breast abnormalities. If done by experts, FNA can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples.
Louvat, Pascale; Bonifacie, Magali; Giunta, Thomas; Michel, Agnès; Coleman, Max
2016-04-05
We describe a novel method for measuring stable bromine isotope compositions in saline solutions such as seawater, brines, and formation waters. Bromine is extracted from the samples by ion exchange chromatography on anion exchange resin AG 1-X4 with NH4NO3 and measured by MC-ICP-MS in wet plasma conditions. Sample introduction through a small spray chamber provided good sensitivity and stability of the Br signal compared to direct injection (d-DIHEN) and desolvation (APEX). NH4NO3 media allowed fast (<3 min) washing of the system. Despite Ar2H(+) spectral interference on (81)Br(+), for the first time low-resolution mode (with appropriate tuning of Ar2H(+)/(81)Br(+) sensitivity) gave higher precision (81)Br/(79)Br measurements than high-resolution (HR), due to the narrowness of the (81)Br(+) plateau in HR mode and to slight mass drifting with time. Additionally, 1 μg Br is the lower amount needed for a triplicate determination of δ(81)Br by MC-ICP-MS, with reproducibility often < ± 0.1‰ (2 SD). Four HBr solutions were prepared by evaporation/condensation in order to obtain in-house reference solutions with 3‰ variations in δ(81)Br and to assess the reproducibility and accuracy of the method. Long-term (>3 years) reproducibility between ± 0.11 and ± 0.27‰ (2 SD) was obtained for the four HBr solutions, the international standard reference material NIST SRM 977 (δ(81)BrSMOB = -0.65 ± 1.1‰, 1 SD), and seawaters (synthetic and natural). The accuracy of the MC-ICP-MS method was validated by comparing the δ(81)Br obtained for these solutions with dual-inlet IRMS measurements on CH3Br gas. Finally, the method was successfully applied to 22 natural samples.
Horodynski, Mildred A; Pierce, Steven J; Reyes-Gastelum, David; Olson, Beth; Shattuck, Mackenzie
2017-12-01
Infant feeding practices are a focus of early obesity prevention. We tested whether infant growth velocity increased after breastfeeding termination and complementary food introduction. Our secondary analysis included a sample of 547 mother-infant dyads from a longitudinal randomized controlled trial conducted in Michigan and Colorado. Infant anthropometrics at birth, baseline, and 6- and 12-month follow-up were standardized to BMI-for-age z-score (ZBMI) according to World Health Organization (WHO) growth charts. We used growth curve models with time-varying predictors to quantify effects of breastfeeding termination and timing of complementary food introduction on growth velocity. Median breastfeeding duration was 2.0 months [confidence interval (CI) = 2.0-2.5]; median introduction of complementary foods occurred at 3.0 months (CI = 2.8-3.2). Breastfed infants not yet introduced to complementary foods had an average ZBMI growth velocity of 0.050 (CI = -0.013 to 0.113) z-score units per month [zpm], not significantly faster than WHO growth trajectory (p = 0.118) defined as 0 zpm. Breastfeeding termination had negligible effect on ZBMI growth velocity (γ 11 = 0.001, CI = -0.027 to 0.030, p = 0.927). Introduction of complementary foods increased ZBMI growth velocity relative to an average child in the sample, but not significantly (γ 12 = 0.033, CI = -0.034 to 0.100, p = 0.334). Growth velocities for infants receiving complementary foods both before and after breastfeeding termination were significantly faster than the WHO growth trajectory (0.083 zpm, CI = 0.052-0.114, and 0.084 zpm, CI = 0.064-0.105, respectively, p's < 0.001). Average postcomplementary food introduction growth velocity was significantly higher than WHO growth trajectory, but did not differ from the sample's initial average trajectory. Growth curve models can accurately estimate effects of feeding practices on infant growth to direct obesity prevention efforts.
Pyen, Grace S.; Browner, Richard F.; Long, Stephen
1986-01-01
A fixed-size simplex has been used to determine the optimum conditions for the simultaneous determination of arsenic, selenium, and antimony by hydride generation and inductively coupled plasma emission spectrometry. The variables selected for the simplex were carrier gas flow rate, rf power, viewing height, and reagent conditions. The detection limit for selenium was comparable to the preoptimized case, but there were twofold and fourfold improvements in the detection limits for arsenic and antimony, respectively. Precision of the technique was assessed with the use of artificially prepared water samples.
Technology Transfer Opportunities: Automated Ground-Water Monitoring
Smith, Kirk P.; Granato, Gregory E.
1997-01-01
Introduction A new automated ground-water monitoring system developed by the U.S. Geological Survey (USGS) measures and records values of selected water-quality properties and constituents using protocols approved for manual sampling. Prototypes using the automated process have demonstrated the ability to increase the quantity and quality of data collected and have shown the potential for reducing labor and material costs for ground-water quality data collection. Automation of water-quality monitoring systems in the field, in laboratories, and in industry have increased data density and utility while reducing operating costs. Uses for an automated ground-water monitoring system include, (but are not limited to) monitoring ground-water quality for research, monitoring known or potential contaminant sites, such as near landfills, underground storage tanks, or other facilities where potential contaminants are stored, and as an early warning system monitoring groundwater quality near public water-supply wells.
Planning for the Introduction of the Metric System into Occupational Education Programs
ERIC Educational Resources Information Center
Low, A. W.
1974-01-01
A three-dimensional planning model for introducting the International System of Metric Units into Canadian occupational education curricula includes employment level, career area, and metric topics. A fourth dimension, time, is considered in four separate phases: familiarization, adoption, conversion, and compulsory usage.
A Technique for Thermal Desorption Analyses Suitable for Thermally-Labile, Volatile Compounds.
Alborn, Hans T
2018-02-01
Many plant and insect interactions are governed by odors released by the plants or insects and there exists a continual need for new or improved methods to collect and identify these odors. Our group has for some time studied below-ground, plant-produced volatile signals affecting nematode and insect behavior. The research requires repeated sampling of volatiles of intact plant/soil systems in the laboratory as well as the field with the help of probes to minimize unwanted effects on the systems we are studying. After evaluating solid adsorbent filters with solvent extraction or solid phase micro extraction fiber sample collection, we found dynamic sampling of small air volumes on Tenax TA filters followed by thermal desorption sample introduction to be the most suitable analytical technique for our applications. Here we present the development and evaluation of a low-cost and relatively simple thermal desorption technique where a cold trap cooled with liquid carbon dioxide is added as an integral part of a splitless injector. Temperature gradient-based focusing and low thermal mass minimizes aerosol formation and eliminates the need for flash heating, resulting in low sample degradation comparable to solvent-based on-column injections. Additionally, since the presence of the cold trap does not affect normal splitless injections, on-the-fly switching between splitless and thermal desorption modes can be used for external standard quantification.
NASA Astrophysics Data System (ADS)
Ardura, Alba; Planes, Serge
2017-03-01
With only a narrow opening through the Gibraltar and Suez Canals, the Mediterranean Sea is one of the largest semi-enclosed seas. The marine flora and fauna are some of the richest in the world, relative to its size, particularly in the coastal habitats, which are also characterized by numerous endemic species although the introduction of non-indigenous species threatens its rich and unique biodiversity. Following the opening of the Suez Canal, and in combination with shipping and aquaculture activities, non-indigenous species (NIS) introduction has had measurable impacts on the Mediterranean. Lagoon ecosystems along the French coastline, with approx. 100 NIS identified, are considered hot-spot areas for these species. Rapid assessment sampling for sessile benthic species together with DNA barcoding is a rapid, easy and cheap method to detect non-indigenous species. Two nearby and different ecosystems were sampled for invertebrate species: Saint-Nazaire lagoon, a Special Protection Area within the Natura 2000 Network and Canet port, a marina in a small village. The DNA barcoding tool for species identification was used for confirming the taxonomy. This showed that, despite the Saint-Nazaire Lagoon classification within the Natura 2000 network, it is already contaminated with a single NIS that was found in high densities and is clearly beginning to dominate the system. It is proposed that a rapid assessment of the sampled environment and the DNA barcode approach are efficient and can provide sufficient information on the new target species to be used in conservation planning and ongoing management efforts.
A new mask exposure and analysis facility
NASA Astrophysics Data System (ADS)
te Sligte, Edwin; Koster, Norbert; Deutz, Alex; Staring, Wilbert
2014-10-01
The introduction of ever higher source powers in EUV systems causes increased risks for contamination and degradation of EUV masks and pellicles. Appropriate testing can help to inventory and mitigate these risks. To this end, we propose EBL2: a laboratory EUV exposure system capable of operating at high EUV powers and intensities, and capable of exposing and analyzing EUV masks. The proposed system architecture is similar to the EBL system which has been operated jointly by TNO and Carl Zeiss SMT since 2005. EBL2 contains an EUV Beam Line, in which samples can be exposed to EUV irradiation in a controlled environment. Attached to this Beam Line is an XPS system, which can be reached from the Beam Line via an in-vacuum transfer system. This enables surface analysis of exposed masks without breaking vacuum. Automated handling with dual pods is foreseen so that exposed EUV masks will still be usable in EUV lithography tools to assess the imaging impact of the exposure. Compared to the existing system, large improvements in EUV power, intensity, reliability, and flexibility are proposed. Also, in-situ measurements by e.g. ellipsometry is foreseen for real time monitoring of the sample condition. The system shall be equipped with additional ports for EUVR or other analysis tools. This unique facility will be open for external customers and other research groups.
Optimal Budget Allocation for Sample Average Approximation
2011-06-01
an optimization algorithm applied to the sample average problem. We examine the convergence rate of the estimator as the computing budget tends to...regime for the optimization algorithm . 1 Introduction Sample average approximation (SAA) is a frequently used approach to solving stochastic programs...appealing due to its simplicity and the fact that a large number of standard optimization algorithms are often available to optimize the resulting sample
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kreisberg, N. M.; Worton, D. R.; Zhao, Y.
A reliable method of sample introduction is presented for online gas chromatography with a special application to in situ field portable atmospheric sampling instruments. A traditional multi-port valve is replaced with a valveless sample introduction interface that offers the advantage of long-term reliability and stable sample transfer efficiency. An engineering design model is presented and tested that allows customizing this pressure-switching-based device for other applications. Flow model accuracy is within measurement accuracy (1%) when parameters are tuned for an ambient-pressure detector and 15% accurate when applied to a vacuum-based detector. Laboratory comparisons made between the two methods of sample introductionmore » using a thermal desorption aerosol gas chromatograph (TAG) show that the new interface has approximately 3 times greater reproducibility maintained over the equivalent of a week of continuous sampling. Field performance results for two versions of the valveless interface used in the in situ instrument demonstrate typically less than 2% week -1 response trending and a zero failure rate during field deployments ranging up to 4 weeks of continuous sampling. Extension of the valveless interface to dual collection cells is presented with less than 3% cell-to-cell carryover.« less
Mississippi Magic: Summer Library Program, 1999.
ERIC Educational Resources Information Center
Hudspeth, Jean; Shurden, Lynn Fletcher
This manual for the 1999 Mississippi summer library program for preschool through elementary age children contains the following sections: (1) Introduction, including planning, promotional activities, sample radio spots and press releases, sample letters to parents, tips for including children with disabilities, a general bibliography, a…
Systems Management for Force Modernization Equipment.
1982-04-15
PERT (New York: John Wiley & Sons, Inc., 1963), p. ’. 8. Fred Luthans, Introduction to Management (New York: McGraw- Hill Book Company, 1976), p...34Fielding Army Systems: Experiences and Lessons Learned." C, Vol. 3, No. 4, Autumn, 1980. Luthans, Fred. Introduction to Management . New York: McGraw
An Introduction to the Federal Information Exchange System.
ERIC Educational Resources Information Center
De Santi, Vincent; Scheele, D. Sam
This publication offers a basic introduction to the Federal Information Exchange System (FIXS), a set of procedures for periodically collecting, processing, and publishing data on federal and state expenditures for each program listed in the "Catalog of Federal Assistance Programs." FIXS is designed for use in conjunction with the…
NASA Technical Reports Server (NTRS)
Regenie, Victoria
2005-01-01
Contents include the following: General Background and Introduction of Capability. Roadmaps for Systems Engineering Cost/Risk Analysis. Agency Objectives. Strategic Planning Transformation. Review Capability Roadmaps and Schedule. Review Purpose of NRC Review. Capability Roadmap Development (Progress to Date).
Naseri, Mohammad Taghi; Hemmatkhah, Payam; Hosseini, Mohammad Reza Milani; Assadi, Yaghoub
2008-03-03
The dispersive liquid-liquid microextraction (DLLME) was combined with the flame atomic absorption spectrometry (FAAS) for determination of lead in the water samples. Diethyldithiophosphoric acid (DDTP), carbon tetrachloride and methanol were used as chelating agent, extraction solvent and disperser solvent, respectively. A new FAAS sample introduction system was employed for the microvolume nebulization of the non-flammable chlorinated organic extracts. Injection of 20 microL volumes of the organic extract into an air-acetylene flame provided very sensitive spike-like and reproducible signals. Some effective parameters on the microextraction and the complex formation were selected and optimized. These parameters include extraction and disperser solvent type as well as their volume, extraction time, salt effect, pH and amount of the chelating agent. Under the optimized conditions, the enrichment factor of 450 was obtained from a sample volume of 25.0 mL. The enhancement factor, calculated as the ratio of the slopes of the calibration graphs with and without preconcentration, which was about 1000. The calibration graph was linear in the range of 1-70 microgL(-1) with a detection limit of 0.5 microgL(-1). The relative standard deviation (R.S.D.) for seven replicate measurements of 5.0 and 50 microgL(-1) of lead were 3.8 and 2.0%, respectively. The relative recoveries of lead in tap, well, river and seawater samples at the spiking level of 20 microgL(-1) ranged from 93.8 to 106.2%. The characteristics of the proposed method were compared with those of the liquid-liquid extraction (LLE), cloud point extraction (CPE), on-line and off-line solid-phase extraction (SPE) as well as co-precipitation, based on bibliographic data. Operation simplicity, rapidity, low cost, high enrichment factor, good repeatability, and low consumption of the extraction solvent at a microliter level are the main advantages of the proposed method.
78 FR 37837 - Agency Information Collection Activities: Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-24
... introduction of a new sample design is planned for the 2014 NSDUH. In addition to moving towards a proportional allocation by state, the 2014 sample design places more sample in the 26 or older age groups than in previous... National Drug Control Policy (ONDCP), Federal government agencies, and other organizations and researchers...
National Sample Survey of Registered Nurses II. Status of Nurses: November 1980.
ERIC Educational Resources Information Center
Bentley, Barbara S.; And Others
This report provides data describing the nursing population as determined by the second national sample survey of registered nurses. A brief introduction is followed by a chapter that presents an overview of the survey methodology, including details on the sampling design, the response rate, and the statistical reliability. Chapter 3 provides a…
Eksler, N D; Vishnevskaia, S S
1989-01-01
The country's socio-economic development necessitates further elaboration of new approaches to the introduction of hygienic research results into practice. The main criterion for choosing proper research techniques lies in their economy-type efficiency, both social, medical and economic. A new system of hygienic research introduction should be based on financial and economic stimuli, establishment of a network of inventive firms, as well as supported by an effective mechanisms of information feed-back with due account of health indices.
Molecular dynamics based enhanced sampling of collective variables with very large time steps.
Chen, Pei-Yang; Tuckerman, Mark E
2018-01-14
Enhanced sampling techniques that target a set of collective variables and that use molecular dynamics as the driving engine have seen widespread application in the computational molecular sciences as a means to explore the free-energy landscapes of complex systems. The use of molecular dynamics as the fundamental driver of the sampling requires the introduction of a time step whose magnitude is limited by the fastest motions in a system. While standard multiple time-stepping methods allow larger time steps to be employed for the slower and computationally more expensive forces, the maximum achievable increase in time step is limited by resonance phenomena, which inextricably couple fast and slow motions. Recently, we introduced deterministic and stochastic resonance-free multiple time step algorithms for molecular dynamics that solve this resonance problem and allow ten- to twenty-fold gains in the large time step compared to standard multiple time step algorithms [P. Minary et al., Phys. Rev. Lett. 93, 150201 (2004); B. Leimkuhler et al., Mol. Phys. 111, 3579-3594 (2013)]. These methods are based on the imposition of isokinetic constraints that couple the physical system to Nosé-Hoover chains or Nosé-Hoover Langevin schemes. In this paper, we show how to adapt these methods for collective variable-based enhanced sampling techniques, specifically adiabatic free-energy dynamics/temperature-accelerated molecular dynamics, unified free-energy dynamics, and by extension, metadynamics, thus allowing simulations employing these methods to employ similarly very large time steps. The combination of resonance-free multiple time step integrators with free-energy-based enhanced sampling significantly improves the efficiency of conformational exploration.
Molecular dynamics based enhanced sampling of collective variables with very large time steps
NASA Astrophysics Data System (ADS)
Chen, Pei-Yang; Tuckerman, Mark E.
2018-01-01
Enhanced sampling techniques that target a set of collective variables and that use molecular dynamics as the driving engine have seen widespread application in the computational molecular sciences as a means to explore the free-energy landscapes of complex systems. The use of molecular dynamics as the fundamental driver of the sampling requires the introduction of a time step whose magnitude is limited by the fastest motions in a system. While standard multiple time-stepping methods allow larger time steps to be employed for the slower and computationally more expensive forces, the maximum achievable increase in time step is limited by resonance phenomena, which inextricably couple fast and slow motions. Recently, we introduced deterministic and stochastic resonance-free multiple time step algorithms for molecular dynamics that solve this resonance problem and allow ten- to twenty-fold gains in the large time step compared to standard multiple time step algorithms [P. Minary et al., Phys. Rev. Lett. 93, 150201 (2004); B. Leimkuhler et al., Mol. Phys. 111, 3579-3594 (2013)]. These methods are based on the imposition of isokinetic constraints that couple the physical system to Nosé-Hoover chains or Nosé-Hoover Langevin schemes. In this paper, we show how to adapt these methods for collective variable-based enhanced sampling techniques, specifically adiabatic free-energy dynamics/temperature-accelerated molecular dynamics, unified free-energy dynamics, and by extension, metadynamics, thus allowing simulations employing these methods to employ similarly very large time steps. The combination of resonance-free multiple time step integrators with free-energy-based enhanced sampling significantly improves the efficiency of conformational exploration.
NASA Astrophysics Data System (ADS)
Miranda, Luis Diego
This dissertation presents the development of novel nano-composite membranes as introduction systems for mass spectrometers. These nano-composite membranes incorporate anodic aluminum oxide (AAO) membranes as templates that can be used by themselves or modified by a variety of chemical deposition processes. Two types of nano-composite membranes are presented. The first nano-composite membrane has carbon deposited within the pores of an AAO membrane. The second nano-composite membrane is made by coating an AAO membrane with a thin polymer film. The following chapters describe the transmission properties these nano-composite membranes and compare them to conventional mass spectrometry introduction systems. The nano- composite membranes were finally coupled to the inlet system of an underwater mass spectrometer revealing their utility in field deployments.
Introduction to Beef Production. Instructor Guide [and] Student Reference.
ERIC Educational Resources Information Center
Duncan, Kevin
This packet contains an instructor guide and student reference for a course in introduction to beef production. The curriculum contains the following seven lessons: (1) introduction to the beef industry; (2) breeds of beef cattle; (3) principles of beef cattle selection; (4) production systems; (5) herd health; (6) herd management; and (7)…
Introduction to Swine Production. Instructor Guide [and] Student Reference.
ERIC Educational Resources Information Center
Duncan, Kevin
This packet contains an instructor guide and student reference for a course in introduction to swine production. The curriculum contains the following seven lessons: (1) introduction to the swine industry; (2) breeds of swine; (3) principles of swine selection; (4) production systems; (5) herd health; (6) herd management; and (6) industry…
Infant rolling abilities--the same or different 20 years after the back to sleep campaign?
Darrah, Johanna; Bartlett, Doreen J
2013-05-01
To compare the order and age of emergence of rolling prone to supine and supine to prone before the introduction of back to sleep guidelines and 20 years after their introduction. The original normative data for the Alberta Infant Motor Scale (AIMS) were collected just prior to the introduction of back to sleep guidelines in 1992. Currently these norms are being re-evaluated. Data of rolling patterns of infants 36 weeks of age or younger from the original sample (n=1114) and the contemporary sample (n=351) were evaluated to compare the sequence of appearance of prone to supine and supine to prone rolls (proportion of infants passing each roll) and the ages of emergence (estimated age when 50% of infants passed each roll). The sequence of emergence and estimated age of appearance of both rolling directions were similar between the two time periods. The introduction of the supine sleep position to reduce the prevalence of Sudden Infant Death Syndrome (SIDS) has not altered the timing or sequence of infant rolling abilities. This information is valuable to health care providers involved in the surveillance of infants' development. Original normative age estimates for these two motor abilities are still appropriate. Copyright © 2012 Elsevier Ltd. All rights reserved.
Gaikowski, M.P.; Larson, W.J.; Steuer, J.J.; Gingerich, W.H.
2004-01-01
Accurate estimates of drug concentrations in hatchery effluent are critical to assess the environmental risk of hatchery drug discharge resulting from disease treatment. This study validated two dilution simple n models to estimate chloramine-T environmental introduction concentrations by comparing measured and predicted chloramine-T concentrations using the US Geological Survey's Upper Midwest Environmental Sciences Center aquaculture facility effluent as an example. The hydraulic characteristics of our treated raceway and effluent and the accuracy of our water flow rate measurements were confirmed with the marker dye rhodamine WT. We also used the rhodamine WT data to develop dilution models that would (1) estimate the chloramine-T concentration at a given time and location in the effluent system and (2) estimate the average chloramine-T concentration at a given location over the entire discharge period. To test our models, we predicted the chloramine-T concentration at two sample points based on effluent flow and the maintenance of chloramine-T at 20 mg/l for 60 min in the same raceway used with rhodamine WT. The effluent sample points selected (sample points A and B) represented 47 and 100% of the total effluent flow, respectively. Sample point B is-analogous to the discharge of a hatchery that does not have a detention lagoon, i.e. The sample site was downstream of the last dilution water addition following treatment. We then applied four chloramine-T flow-through treatments at 20mg/l for 60 min and measured the chloramine-T concentration in water samples collected every 15 min for about 180 min from the treated raceway and sample points A and B during and after application. The predicted chloramine-T concentration at each sampling interval was similar to the measured chloramine-T concentration at sample points A and B and was generally bounded by the measured 90% confidence intervals. The predicted aver,age chloramine-T concentrations at sample points A or B (2.8 and 1.3 mg/l, respectively) were not significantly different (P > 0.05) from the average measured chloramine-T concentrations (2.7 and 1.3 mg/l, respectively). The close agreement between our predicted and measured chloramine-T concentrations indicate either of the dilution models could be used to adequately predict the chloramine-T environmental introduction concentration in Upper Midwest Environmental Sciences Center effluent. (C) 2003 Elsevier B.V. All rights reserved.
20 CFR 416.925 - Listing of Impairments in appendix 1 of subpart P of part 404 of this chapter.
Code of Federal Regulations, 2013 CFR
2013-04-01
... the major body systems impairments that we consider to be severe enough to prevent an individual from... use the listings? (1) Most body system sections in parts A and B of appendix 1 are in two parts: an introduction, followed by the specific listings. (2) The introduction to each body system contains information...
20 CFR 416.925 - Listing of Impairments in appendix 1 of subpart P of part 404 of this chapter.
Code of Federal Regulations, 2014 CFR
2014-04-01
... the major body systems impairments that we consider to be severe enough to prevent an individual from... use the listings? (1) Most body system sections in parts A and B of appendix 1 are in two parts: an introduction, followed by the specific listings. (2) The introduction to each body system contains information...
Deploying Crowd-Sourced Formal Verification Systems in a DoD Network
2013-09-01
INTENTIONALLY LEFT BLANK 1 I. INTRODUCTION A. INTRODUCTION In 2014 cyber attacks on critical infrastructure are expected to increase...CSFV systems on the Internet‒‒possibly using cloud infrastructure (Dean, 2013). By using Amazon Compute Cloud (EC2) systems, DARPA will use ordinary...through standard access methods. Those clients could be mobile phones, laptops, netbooks, tablet computers or personal digital assistants (PDAs) (Smoot
Purchasing a Computer System for the Small Construction Company,
1983-06-08
October 1982. . . . . . . .. i. i...< ..- . ,. .-: i. i? ,. . .-- i * i . . . ., r77- 7 *,~ .- -- 36 IBM - International Business Machines...Corporation, "Small Systems Solutions: An Introduction to Business Computing," Pamphlet SC21-5205-0, Atlanta, Georgia, January 1979. International Business Machines...Corporation, "IBM System/34 Introduction," Pamphlet GC21-5153-5, File No. S34-00, Atlanta, Georgia, January 1979. International Business Machines
Structural controls on the emission of magmatic carbon dioxide gas, Long Valley Caldera, USA
NASA Astrophysics Data System (ADS)
Lucic, Gregor; Stix, John; Wing, Boswell
2015-04-01
We present a degassing study of Long Valley Caldera that explores the structural controls upon emissions of magmatic carbon dioxide gas. A total of 223 soil gas samples were collected and analyzed for stable carbon isotopes using a field-portable cavity ring-down spectrometer. This novel technique is flexible, accurate, and provides sampling feedback on a daily basis. Sampling sites included major and minor volcanic centers, regional throughgoing faults, caldera-related structures, zones of elevated seismicity, and zones of past and present hydrothermal activity. The classification of soil gases based on their δ13C and CO2 values reveals a mixing relationship among three end-members: atmospheric, biogenic, and magmatic. Signatures dominated by biogenic contributions (~4 vol %, -24‰) are found on the caldera floor, the interior of the resurgent dome, and areas associated with the Hilton Creek and Hartley Springs fault systems. With the introduction of the magmatic component (~100 vol %, -4.5‰), samples acquire mixing and hydrothermal signatures and are spatially associated with the central caldera and Mammoth Mountain. In particular, they are concentrated along the southern margin of the resurgent dome where the interplay between resurgence-related reverse faulting and a bend in the regional fault system has created a highly permeable fracture network, suitable for the formation of shallow hydrothermal systems. This contrasts with the south moat, where despite elevated seismicity, a thick sedimentary cover has formed an impermeable cap, inhibiting the ascent of fluids and gases to the surface.
A DUST-SETTLING CHAMBER FOR SAMPLING-INSTRUMENT COMPARISON STUDIES
Introduction: Few methods exist that can evenly and reproducibly deposit dusts onto surfaces for surface-sampling methodological studies. A dust-deposition chamber was designed for that purpose.
Methods: A 1-m3 Rochester-type chamber was modified to produce high airborne d...
47 CFR 1.363 - Introduction of statistical data.
Code of Federal Regulations, 2010 CFR
2010-10-01
... case of sample surveys, there shall be a clear description of the survey design, including the... evidence in common carrier hearing proceedings, including but not limited to sample surveys, econometric... description of the experimental design shall be set forth, including a specification of the controlled...
47 CFR 1.363 - Introduction of statistical data.
Code of Federal Regulations, 2013 CFR
2013-10-01
... case of sample surveys, there shall be a clear description of the survey design, including the... evidence in common carrier hearing proceedings, including but not limited to sample surveys, econometric... description of the experimental design shall be set forth, including a specification of the controlled...
47 CFR 1.363 - Introduction of statistical data.
Code of Federal Regulations, 2014 CFR
2014-10-01
... case of sample surveys, there shall be a clear description of the survey design, including the... evidence in common carrier hearing proceedings, including but not limited to sample surveys, econometric... description of the experimental design shall be set forth, including a specification of the controlled...
47 CFR 1.363 - Introduction of statistical data.
Code of Federal Regulations, 2012 CFR
2012-10-01
... case of sample surveys, there shall be a clear description of the survey design, including the... evidence in common carrier hearing proceedings, including but not limited to sample surveys, econometric... description of the experimental design shall be set forth, including a specification of the controlled...
47 CFR 1.363 - Introduction of statistical data.
Code of Federal Regulations, 2011 CFR
2011-10-01
... case of sample surveys, there shall be a clear description of the survey design, including the... evidence in common carrier hearing proceedings, including but not limited to sample surveys, econometric... description of the experimental design shall be set forth, including a specification of the controlled...
Magnetic Susceptibility: A Practical Introduction.
ERIC Educational Resources Information Center
Greenaway, A. M.; Trail, L. E.
1983-01-01
Describes an experiment in which students: (1) synthesize tris(acetylacetonato)iron(III), tris(diethyldithiocarbamato)iron(III), and chlorobis(diethyldithiocarbmamato)iron(III); (2) are given a sample of potassium hexocyanoferrate(III); and (3) are then asked to measure the room temperature of these samples using the Guoy technique. Background…
Improved format for radiocardiographic data
NASA Technical Reports Server (NTRS)
Dimeff, J.; Sevelius, G.
1973-01-01
Technique involves introduction of radioactive sample into antecubital vein. Scintillation crystal mounted in collimating housing views portion of right and left hearts. As radioactive sample passes through heart, counting rate is measured by crystal and recorded on strip chart. Data is insensitive to geometric effects and other parameters.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zielinska, B.; Harshfield, G.; Fujita, E.
1997-12-31
Volatile organic compounds (VOC) were measured in California`s South Coast Air Basin (SoCAB) during the summers of 1995 and 1996 in order to determine the air quality impacts of the introduction in 1996 of California`s Phase 2 reformulated gasoline (RFG). Over 250 canister and 2,4-dinitrophenylhydrazine (DNPH)-impregnated cartridge samples were collected during each sampling campaign at four sampling sites--two source-dominated sites, a downwind receptor site, and a background site. Canister samples were analyzed for methane, speciated volatile hydrocarbons (C{sub 2}-C{sub 12}), carbon monoxide (CO), carbon dioxide (CO{sub 2}), and methyl tert-butyl ether (MTBE). DNPH were analyzed for C{sub 1}-C{sub 7} carbonylmore » compounds. This paper examines the changes in concentrations of C{sub 2}-C{sub 12} hydrocarbons in the SoCAB resulting from the introduction of Phase 2 RFG with particular emphasis on hydrocarbon species that are most affected by the reformulation.« less
Phylogenetic analysis reveals multiple introductions of Cynodon species in Australia.
Jewell, M; Frère, C H; Harris-Shultz, K; Anderson, W F; Godwin, I D; Lambrides, C J
2012-11-01
The distinction between native and introduced flora within isolated land masses presents unique challenges. The geological and colonisation history of Australia, the world's largest island, makes it a valuable system for studying species endemism, introduction, and phylogeny. Using this strategy we investigated Australian cosmopolitan grasses belonging to the genus Cynodon. While it is believed that seven species of Cynodon are present in Australia, no genetic analyses have investigated the origin, diversity and phylogenetic history of Cynodon within Australia. To address this gap, 147 samples (92 from across Australia and 55 representing global distribution) were sequenced for a total of 3336bp of chloroplast DNA spanning six genes. Data showed the presence of at least six putatively introduced Cynodon species (C. transvaalensis, C. incompletus, C. hirsutus, C. radiatus, C. plectostachyus and C. dactylon) in Australia and suggested multiple recent introductions. C. plectostachyus, a species often confused with C. nlemfuensis, was not previously considered to be present in Australia. Most significantly, we identified two common haplotypes that formed a monophyletic clade diverging from previously identified Cynodon species. We hypothesise that these two haplotypes may represent a previously undescribed species of Cynodon. We provide further evidence that two Australian native species, Brachyachne tenella and B. convergens belong in the genus Cynodon and, therefore, argue for the taxonomic revision of the genus Cynodon. Copyright © 2012 Elsevier Inc. All rights reserved.
Storing and Predicting Dynamic Attributes in a World Model Knowledge Store
2009-05-01
14 CHAPTER 1 INTRODUCTION ... INTRODUCTION The world of mobile, intelligent robotics is expanding rapidly. As the shape, size, function and capabilities of these systems change, so...Ground Vehicles Working Group ( JAUGS WG). JAUGS has since transitioned to encompass the realm of all unmanned systems. It is the goal of the working group
Patterning of ultrathin polymethylmethacrylate films by in-situ photodirecting of the Marangoni flow
NASA Astrophysics Data System (ADS)
Elashnikov, Roman; Fitl, Premysl; Svorcik, Vaclav; Lyutakov, Oleksiy
2017-02-01
Laser heating and Marangoni flow result in the formation of surface structures with different geometries and shape on thin polymer films. By laser beam irradiation combined with a sample movement the solid polymethylmethacrylate (PMMA) films are heated and undergo phase transition which leads to a material flow. Since the laser beam has a non-linear distribution of energy, the PMMA film is heated inhomogeneously and a surface tension gradient in a lateral direction is introduced. During this procedure additional phenomena such as "reversible" or cyclic polymer flow also take place. The careful choice of experimental conditions enables the preparation of patterns with sophisticated geometries and with hierarchical pattern organization. Depending on initial PMMA film thickness and speed of the sample movement line arrays are created, which can subsequently be transformed into the crimped lines or system of circular holes. In addition, the introduction of a constant acceleration in the sample movement or a laser beam distortion enables the preparation of regularly crimped lines, ordered hexagonal holes or overlapped plates.
Lichte, F.E.; Meier, A.L.; Crock, J.G.
1987-01-01
A method of analysis of geological materials for the determination of the rare-earth elements using the Inductively coupled plasma mass spectrometric technique (ICP-MS) has been developed. Instrumental parameters and factors affecting analytical results have been first studied and then optimized. Samples are analyzed directly following an acid digestion, without the need for separation or preconcentration with limits of detection of 2-11 ng/g, precision of ?? 2.5% relative standard deviation, and accuracy comparable to inductively coupled plasma emission spectrometry and instrumental neutron activation analysis. A commercially available ICP-MS instrument is used with modifications to the sample introduction system, torch, and sampler orifice to reduce the effects of high salt content of sample solutions prepared from geologic materials. Corrections for isobaric interferences from oxide ions and other diatomic and triatomic ions are made mathematically. Special internal standard procedures are used to compensate for drift in metahmetal oxide ratios and sensitivity. Reference standard values are used to verify the accuracy and utility of the method.
Chandu, Dilip; Paul, Sudakshina; Parker, Mathew; Dudin, Yelena; King-Sitzes, Jennifer; Perez, Tim; Mittanck, Don W; Shah, Manali; Glenn, Kevin C; Piepenburg, Olaf
2016-01-01
Testing for the presence of genetically modified material in seed samples is of critical importance for all stakeholders in the agricultural industry, including growers, seed manufacturers, and regulatory bodies. While rapid antibody-based testing for the transgenic protein has fulfilled this need in the past, the introduction of new variants of a given transgene demands new diagnostic regimen that allows distinguishing different traits at the nucleic acid level. Although such molecular tests can be performed by PCR in the laboratory, their requirement for expensive equipment and sophisticated operation have prevented its uptake in point-of-use applications. A recently developed isothermal DNA amplification technique, recombinase polymerase amplification (RPA), combines simple sample preparation and amplification work-flow procedures with the use of minimal detection equipment in real time. Here, we report the development of a highly sensitive and specific RPA-based detection system for Genuity Roundup Ready 2 Yield (RR2Y) material in soybean (Glycine max) seed samples and present the results of studies applying the method in both laboratory and field-type settings.
NASA Astrophysics Data System (ADS)
Almirall, Jose R.; Trejos, Tatiana; Hobbs, Andria; Furton, Kenneth G.
2003-09-01
The importance of small amounts of glass and paint evidence as a means to associate a crime event to a suspect or a suspect to another individual has been demonstrated in many cases. Glass is a fragile material that is often found at the scenes of crimes such as burglaries, hit-and-run accidents and violent crime offenses. Previous work has demonstrated the utility of elemental analysis by solution ICP-MS of small amounts of glass for the comparison between a fragment found at a crime scene to a possible source of the glass. The multi-element capability and the sensitivity of ICP-MS combined with the simplified sample introduction of laser ablation prior to ion detection provides for an excellent and relatively non-destructive technique for elemental analysis of glass fragments. The direct solid sample introduction technique of laser ablation (LA) is reported as an alternative to the solution method. Direct solid sampling provides several advantages over solution methods and shows great potential for a number of solid sample analyses in forensic science. The advantages of laser ablation include the simplification of sample preparation, thereby reducing the time and complexity of the analysis, the elimination of handling acid dissolution reagents such as HF and the reduction of sources of interferences in the ionization plasma. Direct sampling also provides for essentially "non-destructive" sampling due to the removal of very small amounts of sample needed for analysis. The discrimination potential of LA-ICP-MS is compared with previously reported solution ICP-MS methods using external calibration with internal standardization and a newly reported solution isotope dilution (ID) method. A total of ninety-one different glass samples were used for the comparison study using the techniques mentioned. One set consisted of forty-five headlamps taken from a variety of automobiles representing a range of twenty years of manufacturing dates. A second set consisted of forty-six automotive glasses (side windows and windshields) representing casework glass from different vehicle manufacturers over several years was also characterized by RI and elemental composition analysis. The solution sample introduction techniques (external calibration and isotope dilution) provide for excellent sensitivity and precision but have the disadvantages of destroying the sample and also involve complex sample preparation. The laser ablation method was simpler, faster and produced comparable discrimination to the EC-ICP-MS and ID-ICP-MS. LA-ICP-MS can provide for an excellent alternative to solution analysis of glass in forensic casework samples. Paints and coatings are frequently encountered as trace evidence samples submitted to forensic science laboratories. A LA-ICP-MS method has been developed to complement the commonly used techniques in forensic laboratories in order to better characterize these samples for forensic purposes. Time-resolved plots of each sample can be compared to associate samples to each other or to discriminate between samples. Additionally, the concentration of lead and the ratios of other elements have been determined in various automotive paints by the reported method. A sample set of eighteen (18) survey automotive paint samples have been analyzed with the developed method in order to determine the utility of LA-ICP-MS and to compare the method to the more commonly used scanning electron microscopy (SEM) method for elemental characterization of paint layers in forensic casework.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-27
... Standard Review Plan, Section 1.0 on Introduction and Interfaces AGENCY: Nuclear Regulatory Commission (NRC... Revision 2 to Standard Review Plan (SRP), Section 1.0, ``Introduction and Interfaces'' (Agencywide Documents Access and Management System (ADAMS) Accession No. ML110110573). The Office of New Reactors (NRO...
Groundwater Sampling at ISCO Sites: Binary Mixtures of Volatile Organic Compounds and Persulfate
In-situ chemical oxidation involves the introduction of a chemical oxidant into the subsurface for the purpose of transforming ground-water contaminants into less harmful byproducts. Due to oxidant persistence, ground water samples collected at hazardous waste sites may contain o...
EPA GROUND WATER ISSUE: Ground Water Sample Preservation at ISCO Sites – Recommended Guidelines
In-situ chemical oxidation (ISCO) involves the introduction of a chemical oxidant into the subsurface for the purpose of transforming ground water contaminants into harmless byproducts. Due to oxidant persistence, ground water samples collected at hazardous waste sites may contai...
Introduction to the Apollo collections. Part 1: Lunar igneous rocks
NASA Technical Reports Server (NTRS)
Mcgee, P. E.; Warner, J. L.; Simonds, C. H.
1977-01-01
The basic petrographic, chemical, and age data is presented for a representative suite of igneous rocks gathered during the six Apollo missions. Tables are given for 69 samples: 32 igneous rocks and 37 impactites (breccias). A description is given of 26 basalts, four plutonic rocks, and two pyroclastic samples. The textural-mineralogic name assigned each sample is included.
Introduction to Field Water-Quality Methods for the Collection of Metals - 2007 Project Summary
Allen, Monica L.
2008-01-01
The U.S. Geological Survey (USGS), Region VI of the U.S. Environmental Protection Agency (USEPA), and the Osage Nation presented three 3-day workshops, in June-August 2007, entitled ?Introduction to Field Water-Quality Methods for the Collection of Metals.? The purpose of the workshops was to provide instruction to tribes within USEPA Region VI on various USGS surface-water measurement methods and water-quality sampling protocols for the collection of surface-water samples for metals analysis. Workshop attendees included members from over 22 tribes and pueblos. USGS instructors came from Oklahoma, New Mexico, and Georgia. Workshops were held in eastern and south-central Oklahoma and New Mexico and covered many topics including presampling preparation, water-quality monitors, and sampling for metals in surface water. Attendees spent one full classroom day learning the field methods used by the USGS Water Resources Discipline and learning about the complexity of obtaining valid water-quality and quality-assurance data. Lectures included (1) a description of metal contamination sources in surface water; (2) introduction on how to select field sites, equipment, and laboratories for sample analysis; (3) collection of sediment in surface water; and (4) utilization of proper protocol and methodology for sampling metals in surface water. Attendees also were provided USGS sampling equipment for use during the field portion of the class so they had actual ?hands-on? experience to take back to their own organizations. The final 2 days of the workshop consisted of field demonstrations of current USGS water-quality sample-collection methods. The hands-on training ensured that attendees were exposed to and experienced proper sampling procedures. Attendees learned integrated-flow techniques during sample collection, field-property documentation, and discharge measurements and calculations. They also used enclosed chambers for sample processing and collected quality-assurance samples to verify their techniques. Benefits of integrated water-quality sample-collection methods are varied. Tribal environmental programs now have the ability to collect data that are comparable across watersheds. The use of consistent sample collection, manipulation, and storage techniques will provide consistent quality data that will enhance the understanding of local water resources. The improved data quality also will help the USEPA better document the condition of the region?s water. Ultimately, these workshops equipped tribes to use uniform sampling methods and to provide consistent quality data that are comparable across the region.
ERIC Educational Resources Information Center
Lowney, Kathleen S.; Price, Anne M.; Gonzalez Guittar, Stephanie
2017-01-01
Given that so many college students take Introduction to Sociology or Social Problems or both, we wondered about the amount of content overlap in these courses. We designed a study that used content analysis of syllabi from these courses in order to measure the amount of convergence between the two classes. In our sample, nearly 70 percent of the…
Fiber-Optic Chemical Sensors and Fiber-Optic Bio-Sensors.
Pospíšilová, Marie; Kuncová, Gabriela; Trögl, Josef
2015-09-30
This review summarizes principles and current stage of development of fiber-optic chemical sensors (FOCS) and biosensors (FOBS). Fiber optic sensor (FOS) systems use the ability of optical fibers (OF) to guide the light in the spectral range from ultraviolet (UV) (180 nm) up to middle infrared (IR) (10 μm) and modulation of guided light by the parameters of the surrounding environment of the OF core. The introduction of OF in the sensor systems has brought advantages such as measurement in flammable and explosive environments, immunity to electrical noises, miniaturization, geometrical flexibility, measurement of small sample volumes, remote sensing in inaccessible sites or harsh environments and multi-sensing. The review comprises briefly the theory of OF elaborated for sensors, techniques of fabrications and analytical results reached with fiber-optic chemical and biological sensors.
Development and validation of an HPLC–MS/MS method to determine clopidogrel in human plasma
Liu, Gangyi; Dong, Chunxia; Shen, Weiwei; Lu, Xiaopei; Zhang, Mengqi; Gui, Yuzhou; Zhou, Qinyi; Yu, Chen
2015-01-01
A quantitative method for clopidogrel using online-SPE tandem LC–MS/MS was developed and fully validated according to the well-established FDA guidelines. The method achieves adequate sensitivity for pharmacokinetic studies, with lower limit of quantifications (LLOQs) as low as 10 pg/mL. Chromatographic separations were performed on reversed phase columns Kromasil Eternity-2.5-C18-UHPLC for both methods. Positive electrospray ionization in multiple reaction monitoring (MRM) mode was employed for signal detection and a deuterated analogue (clopidogrel-d4) was used as internal standard (IS). Adjustments in sample preparation, including introduction of an online-SPE system proved to be the most effective method to solve the analyte back-conversion in clinical samples. Pooled clinical samples (two levels) were prepared and successfully used as real-sample quality control (QC) in the validation of back-conversion testing under different conditions. The result showed that the real samples were stable in room temperature for 24 h. Linearity, precision, extraction recovery, matrix effect on spiked QC samples and stability tests on both spiked QCs and real sample QCs stored in different conditions met the acceptance criteria. This online-SPE method was successfully applied to a bioequivalence study of 75 mg single dose clopidogrel tablets in 48 healthy male subjects. PMID:26904399
Vichapong, Jitlada; Burakham, Rodjana; Srijaranai, Supalax; Grudpan, Kate
2011-07-01
A sequential injection-bead injection-lab-on-valve system was hyphenated to HPLC for online renewable micro-solid-phase extraction of carbamate insecticides. The carbamates studied were isoprocarb, methomyl, carbaryl, carbofuran, methiocarb, promecarb, and propoxur. LiChroprep(®) RP-18 beads (25-40 μm) were employed as renewable sorbent packing in a microcolumn situated inside the LOV platform mounted above the multiposition valve of the sequential injection system. The analytes sorbed by the microcolumn were eluted using 80% acetonitrile in 0.1% acetic acid before online introduction to the HPLC system. Separation was performed on an Atlantis C-18 column (4.6 × 150 mm, 5 μm) utilizing gradient elution with a flow rate of 1.0 mL/min and a detection wavelength at 270 nm. The sequential injection system offers the means of performing automated handling of sample preconcentration and matrix removal. The enrichment factors ranged between 20 and 125, leading to limits of detection (LODs) in the range of 1-20 μg/L. Good reproducibility was obtained with relative standard deviations of <0.7 and 5.4% for retention time and peak area, respectively. The developed method has been successfully applied to the determination of carbamate residues in fruit, vegetable, and water samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Tanaka, Kumiko; Nakada, Taka-Aki; Fukuma, Hiroshi; Nakao, Shota; Masunaga, Naohisa; Tomita, Keisuke; Matsumura, Yosuke; Mizushima, Yasuaki; Matsuoka, Tetsuya
2017-01-23
A sudden shortage of physician resources due to overwhelming patient needs can affect the quality of care in the emergency department (ED). Developing effective response strategies remains a challenging research area. We created a novel system using information and communication technology (ICT) to respond to a sudden shortage, and tested the system to determine whether it would compensate for a shortage. Patients (n = 4890) transferred to a level I trauma center in Japan during 2012-2015 were studied. We assessed whether the system secured the necessary physicians without using other means such as phone or pager, and calculated fulfillment rate by the system as a primary outcome variable. We tested for the difference in probability of multiple casualties among total casualties transferred to the ED as an indicator of ability to respond to excessive patient needs, in a secondary analysis before and after system introduction. The system was activated 24 times (stand-by request [n = 12], attendance request [n = 12]) in 24 months, and secured the necessary physicians without using other means; fulfillment rate was 100%. There was no significant difference in the probability of multiple casualties during daytime weekdays hours before and after system introduction, while the probability of multiple casualties during night or weekend hours after system introduction significantly increased compared to before system introduction (4.8% vs. 12.9%, P < 0.0001). On the whole, the probability of multiple casualties increased more than 2 times after system introduction 6.2% vs. 13.6%, P < 0.0001). After introducing the system, probability of multiple casualties increased. Thus the system may contribute to improvement in the ability to respond to sudden excessive patient needs in multiple causalities. A novel system using ICT successfully secured immediate responses from needed physicians outside the hospital without increasing user workload, and increased the ability to respond to excessive patient needs. The system appears to be able to compensate for a shortage of physician in the ED due to excessive patient transfers, particularly during off-hours.
An Introduction to Logic Control Systems for the Behavioral Scientist, Part I, Text.
ERIC Educational Resources Information Center
Larsen, Lawrence A.
This programed instruction course gives a basic introduction to solid state programing equipment. Course objectives include giving the student (1) a working knowledge of the various types of units used in building digital logic control systems and (2) an idea of how they interconnect to perform different functions. The course has no prerequisites…
ERIC Educational Resources Information Center
Kanda, Katsuya; Mezey, Mathy
1991-01-01
Examined changes in resident acuity and registered nurse staffing in all nursing homes in Pennsylvania before and after introduction of Medicare Prospective Payment System (PPS) in 1983. Found that acuity of nursing home residents increased significantly since introduction of PPS, full-time registered nurse staffing remained unchanged, and…
A Celebration of Neurons: An Educator's Guide to the Human Brain.
ERIC Educational Resources Information Center
Sylwester, Robert
This book provides an introduction to the current scientific understanding of the human brain and its processes. Chapter 1, "At the Edge of a Major Transformation," is an introduction to the field. Chapter 2, "How Our Brain Organizes Itself on the Cellular and Systems Levels," covers what body/brain cellular systems do, how…
Boerebach, Benjamin C M; Lombarts, Kiki M J M H; Arah, Onyebuchi A
2016-03-01
The System for Evaluation of Teaching Qualities (SETQ) was developed as a formative system for the continuous evaluation and development of physicians' teaching performance in graduate medical training. It has been seven years since the introduction and initial exploratory psychometric analysis of the SETQ questionnaires. This study investigates the validity and reliability of the SETQ questionnaires across hospitals and medical specialties using confirmatory factor analyses (CFAs), reliability analysis, and generalizability analysis. The SETQ questionnaires were tested in a sample of 3,025 physicians and 2,848 trainees in 46 hospitals. The CFA revealed acceptable fit of the data to the previously identified five-factor model. The high internal consistency estimates suggest satisfactory reliability of the subscales. These results provide robust evidence for the validity and reliability of the SETQ questionnaires for evaluating physicians' teaching performance. © The Author(s) 2014.
NASA Astrophysics Data System (ADS)
Meiyanti, R.; Subandi, A.; Fuqara, N.; Budiman, M. A.; Siahaan, A. P. U.
2018-03-01
A singer doesn’t just recite the lyrics of a song, but also with the use of particular sound techniques to make it more beautiful. In the singing technique, more female have a diverse sound registers than male. There are so many registers of the human voice, but the voice registers used while singing, among others, Chest Voice, Head Voice, Falsetto, and Vocal fry. Research of speech recognition based on the female’s voice registers in singing technique is built using Borland Delphi 7.0. Speech recognition process performed by the input recorded voice samples and also in real time. Voice input will result in weight energy values based on calculations using Hankel Transformation method and Macdonald Functions. The results showed that the accuracy of the system depends on the accuracy of sound engineering that trained and tested, and obtained an average percentage of the successful introduction of the voice registers record reached 48.75 percent, while the average percentage of the successful introduction of the voice registers in real time to reach 57 percent.
Robert, S; Ravigne, V; Zapater, M-F; Abadie, C; Carlier, J
2012-03-01
Reconstructing and characterizing introduction routes is a key step towards understanding the ecological and evolutionary factors underlying successful invasions and disease emergence. Here, we aimed to decipher scenarios of introduction and stochastic demographic events associated with the global spread of an emerging disease of bananas caused by the destructive fungal pathogen Mycosphaerella fijiensis. We analysed the worldwide population structure of this fungus using 21 microsatellites and 8 sequence-based markers on 735 individuals from 37 countries. Our analyses designated South-East Asia as the source of the global invasion and supported the location of the centre of origin of M. fijiensis within this area. We confirmed the occurrence of bottlenecks upon introduction into other continents followed by widespread founder events within continents. Furthermore, this study suggested contrasting introduction scenarios of the pathogen between the African and American continents. While potential signatures of admixture resulting from multiple introductions were detected in America, all the African samples examined seem to descend from a single successful founder event. In combination with historical information, our study reveals an original and unprecedented global scenario of invasion for this recently emerging disease caused by a wind-dispersed pathogen. © 2012 Blackwell Publishing Ltd.
THE NATIONAL CHILDREN'S STUDY: BEGINNING THE IMPLEMENTATION OF A NATIONAL-PROBABILITY SAMPLE
Introduction: The National Children's Study (NCS) is a longitudinal cohort study that will follow a sample of approximately 100,000 children born in the United States from before birth until 21 years of age. The NCS will investigate the separate and combined effects of environmen...
ERIC Educational Resources Information Center
Inglés, Cándido J.; Aparisi, D.; Delgado, B.; Granados, L.; García-Fernández, José M.
2017-01-01
Introduction: The aim of this study was to analyze the relationship between sociometric types, behavioral categories and self-attributions for academic failure ("Ability", "Effort" or "External Causes") in "Reading", "Mathematics" and "General". Method: The total sample was composed of…
Estimating Aquatic Insect Populations. Introduction to Sampling.
ERIC Educational Resources Information Center
Chihuahuan Desert Research Inst., Alpine, TX.
This booklet introduces high school and junior high school students to the major groups of aquatic insects and to population sampling techniques. Chapter 1 consists of a short field guide which can be used to identify five separate orders of aquatic insects: odonata (dragonflies and damselflies); ephemeroptera (mayflies); diptera (true flies);…
URV Flight Test of an ADA Implemented Self-Repairing Flight Control System
1992-08-01
USE ONLY(Leave blank) I2. REPORT DATE j3.REOTYPANDTSCVRD JAUG 1992 j FINAL 01/01/85--08/31/92 4. TITLE AND SUBTITLE URV FL GHT TEST OF AN ADA IMPLEMESNT...History of the XBQM-106 2 2.0 Self-Repairing Flight Control System 4 Introduction 2.1 Control System Reconfiguration 5 Strategy 2.2 Failure Detection...ji * Ill ’ha A GJ s.d I I I C S U L 3 2.0 Self-Repairing Flight Control System Introduction Self-Repairing Flight Control Systems (SRFCS) are an
NASA Technical Reports Server (NTRS)
Bernacca, P. L.
1971-01-01
The correlation between the equatorial velocities of the components of double stars is studied from a statistical standpoint. A theory of rotational correlation is developed and discussed with regard to its applicability to existing observations. The theory is then applied to a sample of visual binaries which are the least studied for rotational coupling. Consideration of eclipsing systems and spectroscopic binaries is limited to show how the degrees of freedom in the spin parallelism problem can be reduced. The analysis lends support to the existence of synchronism in closely spaced binaries.
Legal and Regulatory Barriers to Reverse Innovation.
Rowthorn, Virginia; Plum, Alexander J; Zervos, John
Reverse innovation, or the importation of new, affordable, and efficacious models to high-income countries from the developing world, has emerged as a way to improve the health care system in the United States. Reverse innovation has been identified as a key emerging trend in global health systems in part because low-resourced settings are particularly good laboratories for low-cost/high-impact innovations that are developed out of necessity. A difficult question receiving scant attention is that of legal and regulatory barriers. The objective of this paper is to understand and elucidate the legal barriers faced by innovators bringing health interventions to the United States. Semistructured qualitative interviews were conducted with 9 key informants who have directly participated in the introduction of global health care approaches to the United States health system. A purposive sampling scheme was employed to identify participants. Phone interviews were conducted over one week in July 2016 with each participant and lasted an average of 35 minutes each. Purely legal barriers included questions surrounding tort liability, standard of care, and concerns around patient-administered self-care. Regulatory burdens included issues of international medical licensure, reimbursement, and task shifting and scope of work challenges among nonprofessionals (e.g. community health workers). Finally, perceived (i.e. not realized or experienced) legal and regulatory barriers to innovative modalities served as disincentives to bringing products or services developed outside of the United States to the United States market. Conflicting interests within the health care system, safety concerns, and little value placed on low-cost interventions inhibit innovation. Legal and regulatory barriers rank among, and contribute to, an anti-innovation atmosphere in healthcare for domestic and reverse innovators alike. Reverse innovation should be fostered through the thoughtful development of legal and regulatory standards that encourage the introduction and scalable adoption of successful health care innovations developed outside of the US, particularly innovations that support public health goals and do not have the benefit of a large corporate sponsor to facilitate introduction to the market. Copyright © 2016 Icahn School of Medicine at Mount Sinai. Published by Elsevier Inc. All rights reserved.
Single-step CE for miniaturized and easy-to-use system.
Ono, Koichi; Kaneda, Shohei; Fujii, Teruo
2013-03-01
We developed a novel single-step capillary electrophoresis (SSCE) scheme for miniaturized and easy to use system by using a microchannel chip, which was made from the hydrophilic material polymethyl methacrylate (PMMA), equipped with a capillary stop valve. Taking the surface tension property of liquids into consideration, the capillary effect was used to introduce liquids and control capillary stop valves in a partial barrier structure in the wall of the microchannel. Through the combined action of stop valves and air vents, both sample plug formation for electrophoresis and sample injection into a separation channel were successfully performed in a single step. To optimize SSCE, different stop valve structures were evaluated using actual microchannel chips and the finite element method with the level set method. A partial barrier structure at the bottom of the channel functioned efficiently as a stop valve. The stability of stop valve was confirmed by a shock test, which was performed by dropping the microchannel chip to a floor. Sample plug deformation could be reduced by minimizing the size of the side partial barrier. By dissolving hydroxyl ethyl cellulose and using it as the sample solution, the EOF and adsorption of the sample into the PMMA microchannel were successfully reduced. Using this method, a 100-bp DNA ladder was concentrated; good separation was observed within 1 min. At a separation length of 5 mm, the signal was approximately 20-fold higher than a signal of original sample solution by field-amplified sample stacking effect. All operations, including liquid introduction and sample separation, can be completed within 2 min by using the SSCE scheme. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Conver, Timothy S.; Koropchak, John A.
1995-06-01
This paper describes detailed work done in our lab to compare analytical figures of merit for pneumatic, ultrasonic and thermospray sample introduction (SI) systems with three different inductively coupled plasma-atomic emission spectrometry (ICP-AES) instruments. One instrument from Leeman Labs, Inc. has an air path echelle spectrometer and a 27 MHz ICP. For low dissolved solid samples with this instrument, we observed that the ultrasonic nebulizer (USN) and fused silica aperture thermospray (FSApT) both offered similar LOD improvements as compared to pneumatic nebulization (PN), 14 and 16 times, respectively. Average sensitivities compared to PN were better for the USN, by 58 times, compared to 39 times for the FSApT. For solutions containing high dissolved solids we observed that FSApT optimized at the same conditions as for low dissolved solids, whereas USN required changes in power and gas flows to maintain a stable discharge. These changes degraded the LODs for USN substantially as compared to those utilized for low dissolved solid solutions, limiting improvement compared to PN to an average factor of 4. In general, sensitivities for USN were degraded at these new conditions. When solutions with 3000 μg/g Ca were analyzed, LOD improvements were smaller for FSApT and USN, but FSApT showed an improvement over USN of 6.5 times. Sensitivities compared to solutions without high dissolved solids were degraded by 19% on average for FSApT, while those for USN were degraded by 26%. The SI systems were also tested with a Varian Instruments Liberty 220 having a vacuum path Czerny-Turner monochromator and a 40 MHz generator. The sensitivities with low dissolved solids solutions compared to PN were 20 times better for the USN and 39 times better for FSApT, and LODs for every element were better for FSApT. Better correlation between relative sensitivities and anticipated relative analyte mass fluxes for FSApT and USN was observed with the Varian instrument. LOD improvements averaged 18 times lower than PN with FSApT while with USN values averaged 8 times lower. When solutions with high dissolved solids were studied it was found that FSApT still offered 5.5 times better LODs than PN and USN offered 4.6 times better LODs than PN. Sensitivities for FSApT averaged 20 times better, while those for USN were 13 times better compared to PN. Finally, background RSDs on the Varian system were generally higher for FSApT than for the USN for similar sample types. A third instrument used for a small set of elements was a Perkin-Elmer model 5500 ICP-AES. This system has a 27 MHz generator with a N 2 purged Czerny-Turner monochromator. LOD trends, background RSDs, and sensitivities were similar to those with the Leeman instrument. However, matrix effects more closely resembled those seen with the Varian instrument for both SI systems. To compare performance and recoveries on a real sample, a National Institute of Standards and Technology, Standard Reference Material 1643c trace elements in water, was analyzed using the Varian system and it was found that both SI systems offered similar recoveries.
Kitamura, Takayuki; Hoshimoto, Hiroyuki; Yamada, Yoshitsugu
2009-10-01
The computerized anesthesia-recording systems are expensive and the introduction of the systems takes time and requires huge effort. Generally speaking, the efficacy of the computerized anesthesia-recording systems on the anesthetic managements is focused on the ability to automatically input data from the monitors to the anesthetic records, and tends to be underestimated. However, once the computerized anesthesia-recording systems are integrated into the medical information network, several features, which definitely contribute to improve the quality of the anesthetic management, can be developed; for example, to prevent misidentification of patients, to prevent mistakes related to blood transfusion, and to protect patients' personal information. Here we describe our experiences of the introduction of the computerized anesthesia-recording systems and the construction of the comprehensive medical information network for patients undergoing surgery in The University of Tokyo Hospital. We also discuss possible efficacy of the comprehensive medical information network for patients during surgery under anesthetic managements.
Berkő, Péter
2016-05-01
It is a regrettable deficiency in the Hungarian healthcare that the culture and the system of quality control of cure have not been formed (except for a few subspecialties, units or wards). If hospital wards do not have a national, professionally unified and modern information system presenting the most important quantity and quality indicators of their medicinal activity annually, a stable basis for definition of future tasks is absent. The author puts forward a proposal for the establishment of the information systems for different professional fields. On the basis of experience of perinatological information system operating for over 3 decades in Borsod-Abaúj-Zemplén county, he also proposes introduction of a nationally unified, Europeristat-compatible information system following Tauffer-statistics which may serve as a uniform quality control of obstetrics and perinatological care, as well as introduction of its base, the dataform "TePERA" (Form of Obstetrics and Perinatological Care Risk).
NASA Astrophysics Data System (ADS)
Kántor, T.; Maestre, S.; de Loos-Vollebregt, M. T. C.
2005-10-01
In the present work electrothermal vaporization (ETV) was used in both inductively coupled plasma mass spectrometry (ICP-MS) and optical emission spectrometry (OES) for sample introduction of solution samples. The effect of (Pd + Mg)-nitrate modifier and CaCl 2 matrix/modifier of variable amounts were studied on ETV-ICP-MS signals of Cr, Cu, Fe, Mn and Pb and on ETV-ICP-OES signals of Ag, Cd, Co, Cu, Fe, Ga, Mn and Zn. With the use of matrix-free standard solutions the analytical curves were bent to the signal axes (as expected from earlier studies), which was observed in the 20-800 pg mass range by ICP-MS and in the 1-50 ng mass range by ICP-OES detection. The degree of curvature was, however, different with the use of single element and multi-element standards. When applying the noted chemical modifiers (aerosol carriers) in microgram amounts, linear analytical curves were found in the nearly two orders of magnitude mass ranges. Changes of the CaCl 2 matrix concentration (loaded amount of 2-10 μg Ca) resulted in less than 5% changes in MS signals of 5 elements (each below 1 ng) and OES signals of 22 analytes (each below 15 ng). Exceptions were Pb (ICP-MS) and Cd (ICP-OES), where the sensitivity increase by Pd + Mg modifier was much larger compared to other elements studied. The general conclusions suggest that quantitative analysis with the use of ETV sample introduction requires matrix matching or matrix replacement by appropriate chemical modifier to the specific concentration ranges of analytes. This is a similar requirement to that claimed also by the most commonly used pneumatic nebulization of solutions, if samples with high matrix concentration are concerned.
Feeding infants and toddlers study: Improvements needed in meeting infant feeding recommendations.
Briefel, Ronette R; Reidy, Kathleen; Karwe, Vatsala; Devaney, Barbara
2004-01-01
To assess adherence to infant feeding recommendations among a sample of infants and toddlers four to 24 months of age in the United States. Descriptive analysis of data collected in the 2002 Feeding Infants and Toddlers Study (FITS) based on telephone interviews and 24-hour dietary recalls collected with the Nutrition Data System for Research of the University of Minnesota. A national random sample of 3,022 infants and toddlers age four to 24 months, including 2,024 infants age four to 11 months. Breastfeeding, timing of introduction of complementary foods, and adherence to infant feeding recommendations. Means and standard errors, percentile distributions, and percentages by age group (four to six months, seven to eight months, and nine to 11 months). About 76% of infants and toddlers were fully or partly breastfed at birth. This percentage declined to 30% at six months and 16% at 12 months-short of Healthy People 2010 goals of 50% and 25%, respectively. The average duration of breastfeeding was 5.5 months for all who initiated breastfeeding. About two-thirds of infants had been introduced to complementary foods between four and six months-the period recommended by the American Academy of Pediatrics (AAP); 17% consumed juice before the AAP recommended age of six months or later. Twenty-two percent of infants nine to 11 months consumed cow's milk on a daily basis before the recommended age of 12 months or later, and one in 10 consumed french fries and/or sweetened beverages on any given day. More parents and caregivers can benefit from guidance about the introduction of developmentally appropriate, micronutrient-rich first solid foods such as iron-rich infant cereals, iron-fortified grain products, meats, soft fruits, and cooked vegetables and the importance of breastfeeding through the first year of life. A smaller proportion of parents and caregivers require guidance on delaying the introduction of juices until six months of age and cow's milk other than formula until one year of age.
Development of an active risk-based surveillance strategy for avian influenza in Cuba.
Ferrer, E; Alfonso, P; Ippoliti, C; Abeledo, M; Calistri, P; Blanco, P; Conte, A; Sánchez, B; Fonseca, O; Percedo, M; Pérez, A; Fernández, O; Giovannini, A
2014-09-01
The authors designed a risk-based approach to the selection of poultry flocks to be sampled in order to further improve the sensitivity of avian influenza (AI) active surveillance programme in Cuba. The study focused on the western region of Cuba, which harbours nearly 70% of national poultry holdings and comprise several wetlands where migratory waterfowl settle (migratory waterfowl settlements - MWS). The model took into account the potential risk of commercial poultry farms in western Cuba contracting from migratory waterfowl of the orders Anseriformes and Charadriiformes through dispersion for pasturing of migratory birds around the MWS. We computed spatial risk index by geographical analysis with Python scripts in ESRI(®) ArcGIS 10 on data projected in the reference system NAD 1927-UTM17. Farms located closer to MWS had the highest values for the risk indicator pj and in total 31 farms were chosen for targeted surveillance during the risk period. The authors proposed to start active surveillance in the study area 3 weeks after the onset of Anseriformes migration, with additional sampling repeated twice in the same selected poultry farms at 15 days interval (Comin et al., 2012; EFSA, 2008) to cover the whole migration season. In this way, the antibody detectability would be favoured in case of either a posterior AI introduction or enhancement of a previous seroprevalence under the sensitivity level. The model identified the areas with higher risk for AIV introduction from MW, aiming at selecting poultry premises for the application of risk-based surveillance. Given the infrequency of HPAI introduction into domestic poultry populations and the relative paucity of occurrences of LPAI epidemics, the evaluation of the effectiveness of this approach would require its application for several migration seasons to allow the collection of sufficient reliable data. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
Introduction | Center for Cancer Research
Introduction The Biophysics Resource (BR) was established in January 2001. Our mission is to provide CCR investigators with access to both the latest instrumentation and expertise in characterizing the biophysical aspects of systems under structural investigation.
Medeiros, Patrícia Muniz de; Ferreira Júnior, Washington Soares; Ramos, Marcelo Alves; Silva, Taline Cristina da; Ladio, Ana Haydée; Albuquerque, Ulysses Paulino
2017-01-01
Efforts have been made to understand the processes that lead to the introduction of exotic species into local pharmacopoeias. Among those efforts, the diversification hypothesis predicts that exotic plants are introduced in local medical systems to amplify the repertoire of knowledge related to the treatment of diseases, filling blanks that were not occupied by native species. Based on such hypothesis, this study aimed to contribute to this discussion using the context of local Brazilian populations. We performed a systematic review of Brazilian studies up to 2011 involving medicinal plants, excluding those studies that presented a high risk of bias (because of sampling or plant identification problems). An analysis of similarities (ANOSIM) was conducted in different scales to test for differences in the repertoire of therapeutic indications treated using native and exotic species. We have found that although there is some overlap between native and exotic plants regarding their therapeutic indications and the body systems (BSs) that they treat, there are clear gaps present, that is, there are therapeutic indications and BSs treated that are exclusive to exotic species. This scenario enables the postulation of two alternative unfoldings of the diversification hypothesis, namely, (1) exotic species are initially introduced to fill gaps and undergo subsequent expansion of their use for medical purposes already addressed using native species and (2) exotic species are initially introduced to address problems already addressed using native species to diversify the repertoire of medicinal plants and to increase the resilience of medical systems. The reasons why exotic species may have a competitive advantage over the native ones, the implications of the introduction of exotic species for the resilience of medical systems, and the contexts in which autochthonous plants can gain strength to remain in pharmacopoeias are also discussed.
Improving microstructural quantification in FIB/SEM nanotomography.
Taillon, Joshua A; Pellegrinelli, Christopher; Huang, Yi-Lin; Wachsman, Eric D; Salamanca-Riba, Lourdes G
2018-01-01
FIB/SEM nanotomography (FIB-nt) is a powerful technique for the determination and quantification of the three-dimensional microstructure in subsurface features. Often times, the microstructure of a sample is the ultimate determiner of the overall performance of a system, and a detailed understanding of its properties is crucial in advancing the materials engineering of a resulting device. While the FIB-nt technique has developed significantly in the 15 years since its introduction, advanced nanotomographic analysis is still far from routine, and a number of challenges remain in data acquisition and post-processing. In this work, we present a number of techniques to improve the quality of the acquired data, together with easy-to-implement methods to obtain "advanced" microstructural quantifications. The techniques are applied to a solid oxide fuel cell cathode of interest to the electrochemistry community, but the methodologies are easily adaptable to a wide range of material systems. Finally, results from an analyzed sample are presented as a practical example of how these techniques can be implemented. Copyright © 2017 Elsevier B.V. All rights reserved.
The introduction of space technology power systems into developing countries
NASA Technical Reports Server (NTRS)
Roberts, Allen F.; Ratajczak, Anthony F.
1989-01-01
Between 1978 and 1984, NASA-Lewis was responsible for the design, fabrication, installation and operational support of 57 photovoltaic power systems in 27 countries. These systems were installed in locations not served by a central power system and ranged in size from 40 W for powering street lights to 29 kW for providing power to a complete village. Several of the system projects had socio/economic studies components that provided for an assessment of how the introduction of both electricity and a novel high technology power system affected the users and their society.
Investigating the widespread introduction of a tropical marine fouling species.
Sheets, Elizabeth A; Cohen, C Sarah; Ruiz, Gregory M; da Rocha, Rosana M
2016-04-01
Little is known about the number and rate of introductions into terrestrial and marine tropical regions, and if introduction patterns and processes differ from temperate latitudes. Botryllid ascidians (marine invertebrate chordates) are an interesting group to study such introduction differences because several congeners have established populations across latitudes. While temperate botryllid invasions have been repeatedly highlighted, the global spread of tropical Botrylloides nigrum (Herdman, 1886) has been largely ignored. We sampled B. nigrum from 16 worldwide warm water locations, including around the Panama Canal, one of the largest shipping hubs in the world and a possible introduction corridor. Using mitochondrial (COI) and nuclear (ANT) markers, we discovered a single species with low genetic divergence and diversity that has established in the Atlantic, Pacific, Indo-Pacific, and Mediterranean Oceans. The Atlantic Ocean contained the highest diversity and multilocus theta estimates and may be a source for introductions to other regions. A high frequency of one mitochondrial haplotype was detected in Pacific populations that may represent a recent introduction in this region. In comparison to temperate relatives, B. nigrum displayed lower (but similar to temperate Botrylloides violaceus) genetic divergence and diversity at both loci that may represent a more recent global spread or differences in introduction pressures in tropical regions. Additionally, chimeras (genetically distinct individuals sharing a single body) were detected in three populations by the mitochondrial locus and validated using cloning, and these individuals contained new haplotype diversity not detected in any other colonies.
Schrempft, S; van Jaarsveld, C H M; Fisher, A; Wardle, J
2013-06-01
To identify family and infant characteristics associated with timing of introduction of two food types: core foods (nutrient-dense) and non-core foods (nutrient-poor) in a population-based sample of mothers and infants. Participants were 1861 mothers and infants from the Gemini twin birth cohort (one child per family). Family and infant characteristics were assessed when the infants were around 8 months old. Timing of introducing core and non-core foods was assessed at 8 and 15 months. As the distributions of timing were skewed, three similar-sized groups were created for each food type: earlier (core: 1-4 months; non-core: 3-8 months), average (core: 5 months; non-core: 9-10 months) and later introduction (core: 6-12 months; non-core: 11-18 months). Ordinal logistic regression was used to examine predictors of core and non-core food introduction, with bootstrapping to test for differences between the core and non-core models. Younger maternal age, lower education level and higher maternal body mass index were associated with earlier core and non-core food introduction. Not breastfeeding for at least 3 months and higher birth weight were specifically associated with earlier introduction of core foods. Having older children was specifically associated with earlier introduction of non-core foods. There are similarities and differences in the characteristics associated with earlier introduction of core and non-core foods. Successful interventions may require a combination of approaches to target both food types.
Earth System Monitoring, Introduction
NASA Astrophysics Data System (ADS)
Orcutt, John
This section provides sensing and data collection methodologies, as well as an understanding of Earth's climate parameters and natural and man-made phenomena, to support a scientific assessment of the Earth system as a whole, and its response to natural and human-induced changes. The coverage ranges from climate change factors and extreme weather and fires to oil spill tracking and volcanic eruptions. This serves as a basis to enable improved prediction and response to climate change, weather, and natural hazards as well as dissemination of the data and conclusions. The data collection systems include satellite remote sensing, aerial surveys, and land- and ocean-based monitoring stations. Our objective in this treatise is to provide a significant portion of the scientific and engineering basis of Earth system monitoring and to provide this in 17 detailed articles or chapters written at a level for use by university students through practicing professionals. The reader is also directed to the closely related sections on Ecological Systems, Introduction and also Climate Change Modeling Methodology, Introduction as well as Climate Change Remediation, Introduction to. For ease of use by students, each article begins with a glossary of terms, while at an average length of 25 print pages each, sufficient detail is presented for use by professionals in government, universities, and industries. The chapters are individually summarized below.
Automated CD-SEM recipe creation technology for mass production using CAD data
NASA Astrophysics Data System (ADS)
Kawahara, Toshikazu; Yoshida, Masamichi; Tanaka, Masashi; Ido, Sanyu; Nakano, Hiroyuki; Adachi, Naokaka; Abe, Yuichi; Nagatomo, Wataru
2011-03-01
Critical Dimension Scanning Electron Microscope (CD-SEM) recipe creation needs sample preparation necessary for matching pattern registration, and recipe creation on CD-SEM using the sample, which hinders the reduction in test production cost and time in semiconductor manufacturing factories. From the perspective of cost reduction and improvement of the test production efficiency, automated CD-SEM recipe creation without the sample preparation and the manual operation has been important in the production lines. For the automated CD-SEM recipe creation, we have introduced RecipeDirector (RD) that enables the recipe creation by using Computer-Aided Design (CAD) data and text data that includes measurement information. We have developed a system that automatically creates the CAD data and the text data necessary for the recipe creation on RD; and, for the elimination of the manual operation, we have enhanced RD so that all measurement information can be specified in the text data. As a result, we have established an automated CD-SEM recipe creation system without the sample preparation and the manual operation. For the introduction of the CD-SEM recipe creation system using RD to the production lines, the accuracy of the pattern matching was an issue. The shape of design templates for the matching created from the CAD data was different from that of SEM images in vision. Thus, a development of robust pattern matching algorithm that considers the shape difference was needed. The addition of image processing of the templates for the matching and shape processing of the CAD patterns in the lower layer has enabled the robust pattern matching. This paper describes the automated CD-SEM recipe creation technology for the production lines without the sample preparation and the manual operation using RD applied in Sony Semiconductor Kyusyu Corporation Kumamoto Technology Center (SCK Corporation Kumamoto TEC).
Fiuzy, Mohammad; Haddadnia, Javad; Mollania, Nasrin; Hashemian, Maryam; Hassanpour, Kazem
2012-01-01
Background Accurate Diagnosis of Breast Cancer is of prime importance. Fine Needle Aspiration test or "FNA”, which has been used for several years in Europe, is a simple, inexpensive, noninvasive and accurate technique for detecting breast cancer. Expending the suitable features of the Fine Needle Aspiration results is the most important diagnostic problem in early stages of breast cancer. In this study, we introduced a new algorithm that can detect breast cancer based on combining artificial intelligent system and Fine Needle Aspiration (FNA). Methods We studied the Features of Wisconsin Data Base Cancer which contained about 569 FNA test samples (212 patient samples (malignant) and 357 healthy samples (benign)). In this research, we combined Artificial Intelligence Approaches, such as Evolutionary Algorithm (EA) with Genetic Algorithm (GA), and also used Exact Classifier Systems (here by Fuzzy C-Means (FCM)) to separate malignant from benign samples. Furthermore, we examined artificial Neural Networks (NN) to identify the model and structure. This research proposed a new algorithm for an accurate diagnosis of breast cancer. Results According to Wisconsin Data Base Cancer (WDBC) data base, 62.75% of samples were benign, and 37.25% were malignant. After applying the proposed algorithm, we achieved high detection accuracy of about "96.579%” on 205 patients who were diagnosed as having breast cancer. It was found that the method had 93% sensitivity, 73% specialty, 65% positive predictive value, and 95% negative predictive value, respectively. If done by experts, Fine Needle Aspiration (FNA) can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples. FNA can be the first line of diagnosis in women with breast masses, at least in deprived regions, and may increase health standards and clinical supervision of patients. Conclusion Such a smart, economical, non-invasive, rapid and accurate system can be introduced as a useful diagnostic system for comprehensive treatment of breast cancer. Another advantage of this method is the possibility of diagnosing breast abnormalities. If done by experts, FNA can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples. PMID:25352966
Spatiotemporal polarization modulation microscopy with a microretarder array
NASA Astrophysics Data System (ADS)
Ding, Changqin; Ulcickas, James R. W.; Simpson, Garth J.
2018-02-01
A patterned microretarder array positioned in the rear conjugate plane of a microscope enables rapid polarizationdependent nonlinear optical microscopy. The pattern introduced to the array results in periodic modulation of the polarization-state of the incident light as a function of position within the field of view with no moving parts or active control. Introduction of a single stationary optical element and a fixed polarizer into the beam of a nonlinear optical microscope enabled nonlinear optical tensor recovery, which informs on local structure and orientation. Excellent agreement was observed between the measured and predicted second harmonic generation (SHG) of z-cut quartz, selected as a test system with well-established nonlinear optical properties. Subsequent studies of spatially varying samples further support the general applicability of this relatively simple strategy for detailed polarization analysis in both conventional and nonlinear optical imaging of structurally diverse samples.
NASA Technical Reports Server (NTRS)
Browning, R.
1986-01-01
A custom scanning Auger electron microscope (SAM) capable of introducing a 3-5 keV electron beam of several nA into a 30 nm diameter sample area was fitted with a sample introduction system and was fully computerized to be used for materials science research. The method of multispectral Auger imaging was devised and implemented. The instrument was applied to various problems in materials science, including the study of the fiber/matrix interface in a SiC reinforced titanium alloy, the study of SiC whiskers in Al alloy 2124 (in cooperation with NASA-Langley), the study of NiCrAl superalloys (in collaboration with NASA-Lewis), the study of zircalloy specimens (in collaboration with Stanford University), and the microstructure of sintered SiC specimens (in collaboration with NASA-Lewis). The report contains a number of manuscripts submitted for publication on these subjects.
PlantDB – a versatile database for managing plant research
Exner, Vivien; Hirsch-Hoffmann, Matthias; Gruissem, Wilhelm; Hennig, Lars
2008-01-01
Background Research in plant science laboratories often involves usage of many different species, cultivars, ecotypes, mutants, alleles or transgenic lines. This creates a great challenge to keep track of the identity of experimental plants and stored samples or seeds. Results Here, we describe PlantDB – a Microsoft® Office Access database – with a user-friendly front-end for managing information relevant for experimental plants. PlantDB can hold information about plants of different species, cultivars or genetic composition. Introduction of a concise identifier system allows easy generation of pedigree trees. In addition, all information about any experimental plant – from growth conditions and dates over extracted samples such as RNA to files containing images of the plants – can be linked unequivocally. Conclusion We have been using PlantDB for several years in our laboratory and found that it greatly facilitates access to relevant information. PMID:18182106
Ferrareze, M; Nogueira, M G
2015-11-01
This study aimed to understand how the introduction of Cichla kelberi in Rosana Reservoir (Paranapanema River) affected the native ichthyofauna. Data on the structure of the small fish fauna assemblage were obtained before and after the introduction of this carnivorous species. Samplings were carried out in February and September of 2004, previously to the register of Cichla kelberi in the reservoir, and after its introduction, November of 2004, January, March, May and August of 2005, February and June of 2006, February and July of 2007, February and October of 2008 and February of 2009. A total of 4,693 fish, belonging to 43 different species was sampled between 2004 and 2009. The order Characiformes was the most abundant, followed by Perciformes and Siluriformes. Comparative analyses, before and after the introduction, could not demonstrate significant changes in composition, richness, abundance, biomass, mean length and diversity of fish. Aquatic insects were the main feeding item of C. kelberi, followed by tetragonopterinae fish. Cannibalism was recorded during the whole study period. The results showed that Cichla cannot deeply affect the ichthyofauna assemblages of a large Neotropical reservoir, at least in a short or medium term period after its introduction. The results also allowed concluding that the introduction of C. kelberi in the reservoir is in the phase 3. In this phase, the specie can survive and reproduce in the new environment; however it is not totally established and disseminated. The reasons for the fact that Cichla is still not dominant in Rosana Reservoir could be related to feeding competition, high rate of cannibalism and the presence of large amount of aquatic macrophytes (refuge zones). In spite of the results, the continuous monitoring of the role of non-native species on the local fish fauna is absolutely necessary because the impacts caused by colonization of this undesirable species can be magnified by complex processes, usually correlated with other environmental disturb, especially the negative effects of damming.
1991-09-01
iv III. THE ANALYTIC HIERARCHY PROCESS ..... ........ 15 A. INTRODUCTION ...... ................. 15 B. THE AHP PROCESS ...... ................ 16 C...INTRODUCTION ...... ................. 26 B. IMPLEMENTATION OF CERTS USING AHP ........ .. 27 1. Consistency ...... ................ 29 2. User Interface...the proposed technique into a Decision Support System. Expert Choice implements the Analytic Hierarchy Process ( AHP ), an approach to multi- criteria
ERIC Educational Resources Information Center
Luckett, Kathy
2007-01-01
This paper analyses the take-up of proposals for a national quality assurance system in South Africa using different approaches to quality assurance to classify stakeholder responses to survey and interview questions. The context of the study was the introduction of an external quality assurance system for South African higher education by an…
ERIC Educational Resources Information Center
Schulz, Russel E.; Farrell, Jean R.
This resource guide for the use of job aids ("how-to-do-it" guidance) for activities identified in the second phase of the Instructional Systems Development Model (ISD) contains an introduction to the use of job aids, as well as descriptive authoring flowcharts for Blocks II.1 through II.4. The introduction includes definitions;…
ERIC Educational Resources Information Center
Schulz, Russel E.; Farrell, Jean R.
This resource guide for the use of job aids ("how-to-do-it" guidance) for activities identified in the first phase of the Instructional Systems Development Model (ISD) contains an introduction to the use of job aids, as well as descriptive authoring flowcharts for Blocks I.2 through I.5. The introduction includes definitions;…
Open Systems Architecture for Command, Control and Communications
1991-07-01
CONTENTS SECTION TITLE PAGE I. EXECUTIVE SUMMARY 5 II. TERMS OF REFERENCE 7 III. PANEL MEMBERSHIP 9 IV. INTRODUCTION 11 V. INDUSTRIAL REVOLUTION 19 VI...INTRODUCTION 18 19 V. INDUSTRIAL REVOLUTION 20 21 Initial manifestations of computer and communications standards emerged in the early seventies, largely...SYSTEMS INDUSTRIAL REVOLUTION Application Presentation Session Transport Internet Data Link Physical Application Presentation Session Transport
ERIC Educational Resources Information Center
Schulz, Russel E.; Farrell, Jean R.
This resource guide for the use of job aids ("how-to-do-it" guidance) for activities identified in the third phase of the Instructional Systems Development Model (ISD) contains an introduction to the use of job aids, as well as descriptive authoring flowcharts for Blocks III.1 through III.5. The introduction includes definitions;…
Measurement-Based Investigation of Inter- and Intra-Area Effects of Wind Power Plant Integration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allen, Alicia J.; Singh, Mohit; Muljadi, Eduard
This paper has a two pronged objective: the first objective is to analyze the general effects of wind power plant (WPP) integration and the resulting displacement of conventional power plant (CPP) inertia on power system stability and the second is to demonstrate the efficacy of PMU data in power system stability analyses, specifically when knowledge of the network is incomplete. Traditionally modal analysis applies small signal stability analysis based on Eigenvalues and the assumption of complete knowledge of the network and all of its components. The analysis presented here differs because it is a measurement-based investigation and employs simulated measurementmore » data. Even if knowledge of the network were incomplete, this methodology would allow for monitoring and analysis of modes. This allows non-utility entities and study of power system stability. To generate inter- and intra-area modes, Kundur's well-known two-area four-generator system is modeled in PSCAD/EMTDC. A doubly-fed induction generator based WPP model, based on the Western Electricity Coordination Council (WECC) standard model, is included to analyze the effects of wind power on system modes. The two-area system and WPP are connected in various configurations with respect to WPP placement, CPP inertia and WPP penetration level. Analysis is performed on the data generated by the simulations. For each simulation run, a different configuration is chosen and a large disturbance is applied. The sampling frequency is set to resemble the sampling frequency at which data is available from phasor measurement units (PMUs). The estimate of power spectral density of these signals is made using the Yule-Walker algorithm. The resulting analysis shows that the presence of a WPP does not, of itself, lead to the introduction of new modes. The analysis also shows however that displacement of inertia may lead to introduction of new modes. The effects of location of inertia displacement (i.e. the effects on modes if WPP integration leads to displacement of inertia in its own region or in another region) and of WPP controls such as droop control and synthetic inertia are also examined. In future work, the methods presented here will be applied to real-world phasor data to examine the effects of integration of variable generation and displacement of CPP inertia on inter- and intra-area modes.« less
Aerodynamic Characteristics of Controls.
1979-09-01
efforts. CONTENT 1. Introduction 2. Subsonic attached flow 3. Transonic attached flow 4. Supersonic attached flow 5. Leading edge vortex flow 6... introduction of these loading functions the integral-equation is reduced to a system of linear equations where the scale factors of the loading... introduction of different regions of influence for the subsonic and the supersonic case 1511. In the unsteady case this brings no difficulties since these
Microbiome in the Apical Root Canal System of Teeth with Post-Treatment Apical Periodontitis
Siqueira, José F.; Antunes, Henrique S.; Rôças, Isabela N.; Rachid, Caio T. C. C.
2016-01-01
Introduction Bacteria present in the apical root canal system are directly involved with the pathogenesis of post-treatment apical periodontitis. This study used a next-generation sequencing approach to identify the bacterial taxa occurring in cryopulverized apical root samples from root canal-treated teeth with post-treatment disease. Methods Apical root specimens obtained during periradicular surgery of ten adequately treated teeth with persistent apical periodontitis were cryogenically ground. DNA was extracted from the powder and the microbiome was characterized on the basis of the V4 hypervariable region of the 16S rRNA gene by using paired-end sequencing on Illumina MiSeq device. Results All samples were positive for the presence of bacterial DNA. Bacterial taxa were mapped to 11 phyla and 103 genera composed by 538 distinct operational taxonomic units (OTUs) at 3% of dissimilarity. Over 85% of the sequences belonged to 4 phyla: Proteobacteria, Firmicutes, Fusobacteria and Actinobacteria. In general, these 4 phyla accounted for approximately 80% of the distinct OTUs found in the apical root samples. Proteobacteria was the most abundant phylum in 6/10 samples. Fourteen genera had representatives identified in all cases. Overall, the genera Fusobacterium and Pseudomonas were the most dominant. Enterococcus was found in 4 cases, always in relatively low abundance. Conclusions This study showed a highly complex bacterial community in the apical root canal system of adequately treated teeth with persistent apical periodontitis. This suggests that this disease is characterized by multispecies bacterial communities and has a heterogeneous etiology, because the community composition largely varied from case to case. PMID:27689802
Woskov, Paul P.; Cohn, Daniel R.; Titus, Charles H.; Surma, Jeffrey E.
1997-01-01
Microwave-induced plasma for continuous, real time trace element monitoring under harsh and variable conditions. The sensor includes a source of high power microwave energy and a shorted waveguide made of a microwave conductive, high temperature capability refractory material communicating with the source of the microwave energy to generate a plasma. The high power waveguide is constructed to be robust in a hot, hostile environment. It includes an aperture for the passage of gases to be analyzed and a spectrometer is connected to receive light from the plasma. Provision is made for real time in situ calibration. The spectrometer disperses the light, which is then analyzed by a computer. The sensor is capable of making continuous, real time quantitative measurements of desired elements, such as the heavy metals lead and mercury. The invention may be incorporated into a high temperature process device and implemented in situ for example, such as with a DC graphite electrode plasma arc furnace. The invention further provides a system for the elemental analysis of process streams by removing particulate and/or droplet samples therefrom and entraining such samples in the gas flow which passes through the plasma flame. Introduction of and entraining samples in the gas flow may be facilitated by a suction pump, regulating gas flow, gravity or combinations thereof.
Enjeti, Anoop; Granter, Neil; Ashraf, Asma; Fletcher, Linda; Branford, Susan; Rowlings, Philip; Dooley, Susan
2015-10-01
An automated cartridge-based detection system (GeneXpert; Cepheid) is being widely adopted in low throughput laboratories for monitoring BCR-ABL1 transcript in chronic myelogenous leukaemia. This Australian study evaluated the longitudinal performance specific characteristics of the automated system.The automated cartridge-based system was compared prospectively with the manual qRT-PCR-based reference method at SA Pathology, Adelaide, over a period of 2.5 years. A conversion factor determination was followed by four re-validations. Peripheral blood samples (n = 129) with international scale (IS) values within detectable range were selected for assessment. The mean bias, proportion of results within specified fold difference (2-, 3- and 5-fold), the concordance rate of major molecular remission (MMR) and concordance across a range of IS values on paired samples were evaluated.The initial conversion factor for the automated system was determined as 0.43. Except for the second re-validation, where a negative bias of 1.9-fold was detected, all other biases fell within desirable limits. A cartridge-specific conversion factor and efficiency value was introduced and the conversion factor was confirmed to be stable in subsequent re-validation cycles. Concordance with the reference method/laboratory at >0.1-≤10 IS was 78.2% and at ≤0.001 was 80%, compared to 86.8% in the >0.01-≤0.1 IS range. The overall and MMR concordance were 85.7% and 94% respectively, for samples that fell within ± 5-fold of the reference laboratory value over the entire period of study.Conversion factor and performance specific characteristics for the automated system were longitudinally stable in the clinically relevant range, following introduction by the manufacturer of lot specific efficiency values.
NASA Technical Reports Server (NTRS)
Mercado, AL; Marsden, Paul
1995-01-01
Ion Mobility Spectrometry (IMS) is currently being successfully applied to the problem of on-line trace detection of plastic and other explosives in airports and other facilities. The methods of sample retrieval primarily consist of batch sampling for particulate residue on a filter card for introduction into the IMS. The sample is desorbed into the IMS using air as the carrier and negative ions of the explosives are detected, some as an adduct with a reagent ion such as Cl(-). Based on studies and tests conducted by different airport authorities, this method seems to work well for low vapor pressure explosives such as RDX and PETN, as well as TNT that are highly adsorptive and can be found in nanogram quantities on contaminated surfaces. Recently, the changing terrorist threat and the adoption of new marking agents for plastic explosives has meant that the sample introduction and analysis capabilities of the IMS must be enhanced in order to keep up with other detector developments. The IMS has sufficient analytical resolution for a few threat compounds but the IMS Plasmogram becomes increasingly more difficult to interpret when the sample mixture gets more complex.
Abdelnour, Arturo; Arguedas, Adriano; Dagan, Ron; Soley, Carolina; Porat, Nurith; Castrejon, Maria Mercedes; Ortega-Barria, Eduardo; Colindres, Romulo; Pirçon, Jean-Yves; DeAntonio, Rodrigo; Van Dyke, Melissa K
2015-01-01
Acute otitis media (AOM) microbiology was evaluated in children after 7-valent pneumococcal conjugate vaccine (PCV7) introduction in Costa Rica (private sector, 2004; National Immunization Program, 2009). This was a combined prospective and retrospective study conducted in a routine clinical setting in San José, Costa Rica. In the prospective part of the study, which was conducted post-PCV7 introduction (2010-2012), standard bacteriological procedures were used to evaluate the etiology and serotype distribution of middle ear fluid samples collected by tympanocentesis or otorrhea from children aged 3-59 months diagnosed with AOM. E-tests were used to evaluate antimicrobial susceptibility in culture-positive samples. Retrospective data recorded between 1999 and 2004 were used for comparison of bacterial etiology and serotype distribution before and after PCV7 introduction. Statistical significance was evaluated in bivariate analyses at the P-value < 0.05 level (without multiplicity correction). Post-PCV7 introduction, Haemophilus influenzae was detected in 118/456 and Streptococcus pneumoniae in 87/456 AOM episodes. Most H. influenzae isolates (113/118) were non-typeable. H. influenzae was more (27.4% vs 20.8%) and S. pneumoniae less (17.1% vs 25.5%) frequently observed in vaccinated (≥ 2 PCV7 doses or ≥ 1 PCV7 dose at >1 year of age) versus unvaccinated children. S. pneumoniae non-susceptibility rates were 1.1%, 34.5%, 31.7%, and 50.6% for penicillin, erythromycin, azithromycin, and trimethoprim/sulfamethoxazole (TMP-SMX), respectively. H. influenzae non-susceptibility rate was 66.9% for TMP-SMX. Between pre- and post-PCV7 introduction, H. influenzae became more (20.5% vs 25.9%; P-value < 0.001) and S. pneumoniae less (27.7% vs 19.1%; P-value = 0.002) prevalent, and PCV7 serotype proportions decreased among pneumococcal isolates (65.8% vs 43.7%; P-value = 0.0005). Frequently identified pneumococcal serotypes were 19F (34.2%), 3 (9.7%), 6B (9.7%), and 14 (9.7%) pre-PCV7 introduction, and 19F (27.6%), 14 (8.0%), and 35B (8.0%) post-PCV7 introduction. Following PCV7 introduction, a change in the distribution of AOM episodes caused by H. influenzae and pneumococcal serotypes included in PCV7 was observed in Costa Rican children. Pneumococcal vaccines impact should be further evaluated following broader vaccination coverage.
Effects of the Spock Videogame on Improving Emotional Intelligence in Adolescents
ERIC Educational Resources Information Center
Cejudo, Javier; Latorre, Sebastián
2015-01-01
Introduction: The aim of the present research is to experimentally assess the effects of a videogame program ("Spock") for improving emotional intelligence (EI) as an ability among a sample of adolescents. Method: The sample was made up of 92 adolescents, aged 17 to 19, who were currently studying the second year of…
Spectrometer Sensitivity Investigations on the Spectrometric Oil Analysis Program.
1983-04-22
31 H. ACID DISSOLUTION METHOD (ADM) ........... 90 31 I. ANALYSIS OF SAMPLES............................ 31 jJ. PARTICLE TRANSPORT EFFICIENCY OF...THE ROTATING *DISK.................................... 32 I .K. A/E35U-3 ACID DISSOLUTION METHOD.................. 32 L. BURN TIME... ACID DISSOLUTION METHOD ......... ,...,....... 95 3. EFFECT OF BURN TIME ............ 95 4. DIRECT SAMPLE INTRODUCTION .......................... 95
USDA-ARS?s Scientific Manuscript database
Most analytical methods for persistent organic pollutants (POPs) focus on targeted analytes. Therefore, analysis of multiple classes of POPs typically entails several sample preparations, fractionations, and injections, whereas other chemicals of possible interest are neglected. To analyze a wider...
Ashraf, Hengameh; Samiee, Mohammad; Eslami, Gita; Ghodse Hosseini, Mohammad Reza
2007-01-01
INTRODUCTION: An important consideration in endodontic treatment is the elimination of microorganisms, including fungi, from the complex three- dimensional root canal system. Candida Albicans (CA) has a major role in endodontic treatment failure as the most important fungus isolated from the root canal system. The present study was carried out to evaluate the presence of CA in the teeth requiring endodontic retreatment, with or without periapical lesions. MATERIALS AND METHODS: This study was carried out on 60 root canals from human molars requiring endodontic retreatment. The root canals were randomly divided into two equal groups of 30 canals with versus without periapical lesions. Samples were collected from the root canals and cultured on MacConkey and blood agar culture media. The samples suspected of having CA were streaked on Sabouraud’s Dextrose Agar (SDA) and evaluated under a light microscope. Data was analyzed and compared using Chi- square and Kappa tests. RESULTS: CA was found in 11 patients (36.7%) with periapical lesions. In the patients without periapical lesions only 4 samples demonstrated CA in the root canal systems (13.3%). The difference between the two groups as to the presence of CA was statistically significant (p<0.037). In addition, evaluation of salivary samples revealed 15 cases (50%) of CA presence in the patients with periapical lesions and 16 cases (53.3%) of CA in the patients without periapical lesions, demonstrating no statistically significant difference between the two groups. CONCLUSION: Considering the fact that the presence of CA in the root canal systems of teeth with periapical lesions was more noticeable and statistically significant compared to the teeth without periapical lesions, the elimination of this microorganism from the root canal system, using appropriate intracanal solutions and medications is of utmost importance. PMID:24348654
Thomas, Elaine
2005-01-01
This article is the second in a series of three that will give health care professionals (HCPs) a sound introduction to medical statistics (Thomas, 2004). The objective of research is to find out about the population at large. However, it is generally not possible to study the whole of the population and research questions are addressed in an appropriate study sample. The next crucial step is then to use the information from the sample of individuals to make statements about the wider population of like individuals. This procedure of drawing conclusions about the population, based on study data, is known as inferential statistics. The findings from the study give us the best estimate of what is true for the relevant population, given the sample is representative of the population. It is important to consider how accurate this best estimate is, based on a single sample, when compared to the unknown population figure. Any difference between the observed sample result and the population characteristic is termed the sampling error. This article will cover the two main forms of statistical inference (hypothesis tests and estimation) along with issues that need to be addressed when considering the implications of the study results. Copyright (c) 2005 Whurr Publishers Ltd.
Yang, Ju-Hyun; Kim, Mira; Park, Young-Taek; Lee, Eui-Kyung; Jung, Chai Young; Kim, Sukil
2015-11-01
Outpatient clinics in Korea usually have local DUR (drug utilisation review) systems, which are integrated with EMRs or health insurance claims submission systems. Whenever, the government announces a list of drug contraindications, each local DUR system loads the list and applies it in practice. In December 2010, a nationwide DUR system was introduced. This study is to investigate the impact of the nationwide DUR system on prescribing practices where local DUR systems are already operating. Between January 2009 and December 2012 the monthly number of drugs per prescription was retrieved from the health insurance claims data warehouse at the Health Insurance Review and Assessment (HIRA). The monthly proportions of 3 DDI (drug-drug interaction) pairs, 6 drug-age contraindications, and 3 drug-pregnancy contraindications from January 2007 to December 2012, at the outpatient clinic level, were also retrieved. An interrupted time series analysis was used for controlling government announcements of drug contraindications. There was no difference in the number of drugs per prescription before and after the introduction of the nationwide DUR system. Most proportions of the 3 DDI pairs, 6 drug-age contraindications, and 3 drug-pregnancy contraindications, were significantly reduced following the government announcement of drug contraindications in the short term and/or long term. The number of drugs per prescription was not related to the nationwide DUR introduction in places where local DUR systems are operating. The introduction of duplicate guidelines, in locations where the guidelines were already well followed, is considered to be the main reason for this. Furthermore, the Doctor's ignorance of alerts, and their continued substitution of regulated drugs, for non-regulated drugs, likely played a role in nullifying the effectiveness of the nationwide DUR system. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Fragoso-Moura, E N; Oporto, L T; Maia-Barbosa, P M; Barbosa, F A R
2016-02-01
The introduction of species has become an important problem for biodiversity and natural ecosystem conservation. The lake system of the middle Rio Doce (MG, Brazil) comprises c. 200 lakes at various conservation states, of which 50 are located within the Rio Doce State Park (PERD). Previous studies had verified several of these lakes suffered non-native fishes introductions and the presence of these species needs for the implementation of actions aiming at not only their control but also the preservation of the native species. This study discusses the effects of non-native fish species in the largest conservation unit of Atlantic Forest in Minas Gerais, southeast of Brazil, using data from 1983 to 2010 distributed as follow: data prior to 2006 were obtained from previous studies, and data from September 2006 to July 2010 were obtained in Lake Carioca at four sampling stations using gillnets, seine nets and sieve. A total of 17 fish species was collected (2006-2010) of which five were introduced species. Among the small to medium size native species (30 to 2000 mm standard length) seven had disappeared, two are new records and one was recaptured. The non-native species Cichla kelberi (peacock bass) and Pygocentrus nattereri (red piranha) are within the most abundant captured species. Integrated with other actions, such as those preventing new introductions, a selective fishing schedule is proposed as an alternative approach to improve the conservation management actions and the local and regional biodiversity maintenance.
1974-08-31
vision, guidance and outstanding direction of Ouida C. Upchurch, Capt., NC, USN, Project Manager. 1 TABLE OF CONTENTS Unit Page IA INTRODUCTION TO THE...DEPARTMENT .. ......... ... 19 ICI. Orientation to the Navy Medical Department ... ...... 21 ID INTRODUCTION TO OBSERVATION, COMMUNICATION, AND INSTRUCTIONAL...Surgical Wounds: Irrigations .... ............ ... 597 IR8. Surgical Wounds: Suture Removal .. .......... ... 601 vi AhI TRAINING UNIT IA INTRODUCTION TO
Andrade, Vera Lúcia Fonseca; Fernandes, Filipa Alexandra Veludo
2016-01-01
to describe strategies used by health professionals on the implementation of the Centers for Disease Control and Prevention guidelines for the prevention of urinary infection related to catheterism. systematic review on literature based on data from CINAHL(r), Nursing & Allied Health Collection, Cochrane Plus Collection, MedicLatina, MEDLINE(r), Academic Search Complete, ACS - American Chemical Society, Health Reference Center Academic, Nursing Reference Center, ScienceDirect Journals and Wiley Online Library. A sample of 13 articles was selected. studies have highlighted the decrease of urinary tract infection related to catheterism through reminder systems to decrease of people submitted to urinary catheterism, audits about nursing professionals practice and bundles expansion. the present review systemizes the knowledge of used strategies by health professionals on introduction to international recommendations, describing a rate decrease of such infection in clinical practice.
Fiber-Optic Chemical Sensors and Fiber-Optic Bio-Sensors
Pospíšilová, Marie; Kuncová, Gabriela; Trögl, Josef
2015-01-01
This review summarizes principles and current stage of development of fiber-optic chemical sensors (FOCS) and biosensors (FOBS). Fiber optic sensor (FOS) systems use the ability of optical fibers (OF) to guide the light in the spectral range from ultraviolet (UV) (180 nm) up to middle infrared (IR) (10 µm) and modulation of guided light by the parameters of the surrounding environment of the OF core. The introduction of OF in the sensor systems has brought advantages such as measurement in flammable and explosive environments, immunity to electrical noises, miniaturization, geometrical flexibility, measurement of small sample volumes, remote sensing in inaccessible sites or harsh environments and multi-sensing. The review comprises briefly the theory of OF elaborated for sensors, techniques of fabrications and analytical results reached with fiber-optic chemical and biological sensors. PMID:26437407
NASA Astrophysics Data System (ADS)
Kuba, Takahiro; Yasufuku, Noriyuki
A new evaluation system was introduced to the graduation research in the Civil Engineering Course, Department of Earth Resources, Marine and Civil Engineering, Kyushu University. The purpose of the graduation research was also specified, and it was shared by all the students and the educators in the course. Consequently, the introduction of the system apparently led to education improvement for the educators, as well as learning improvement for the students, e.g., their presentation ability and communications skills have improved.
[Incident reporting systems in anesthesiology--methods and benefits using the example of PaSOS].
Rall, Marcus; Reddersen, Silke; Zieger, Jörg; Schädle, Bertram; Hirsch, Patricia; Stricker, Eric; Martin, Jörg; Geldner, Götz; Schleppers, Alexander
2008-09-01
Preventing patient harm is one of the main tasks for the field of anesthesiology from early on. With the introduction of the national German incident reporting system PaSOS, which is hosted by the German anesthesia society, anesthesiology is again leading the field of patient safety. Important elements, success factors and background information for the introduction of successful incident reporting systems in an organization are given. Examples by and from PaSOS are given.
Introduction to Dynamic Bifurcation.
1983-05-01
D-Ai33 252 INTRODUCTION TO DYNAMIC BIFtJRCATION(U) BROWIN UNIV PROVIDENCE RI LEFSCHETZ CENTER FOR DYNAMICAL SYSTEMS J K HALE MAY 83 LCDS-83-16 AFOSR...AV 04 Lefschetz Center for Dynamical Systems 0@0 UNCLASSIFIED. %;". "" I " PO. T NUMUER i2 ACCLSSIONNO .l l’. " . 0’l . 11...A0., .,N ; Lefschet; Center for Dynamical Systems Div. of Applied Math., Prov., R.I. 02912 PE61102F; 2304/A4 "t. CONTrOLLING OFFICE NAME AND ADORESS
NASA Astrophysics Data System (ADS)
Place, P., Jr.; Petrenko, V. V.; Vimont, I.
2017-12-01
Carbon Monoxide (CO) is an important atmospheric trace gas that affects the oxidative capacity of the atmosphere and contributes indirectly to anthropogenic radiative forcing. Carbon monoxide stable isotopes can also serve as a tracer for variations in biomass burning, particularly in the preindustrial atmosphere. A good understanding of the past variations in CO mole fractions and isotopic composition can help improve the skill of chemical transport models and constrain biomass burning changes. Ice cores may preserve a record of past atmospheric CO for analysis and interpretation. To this end, a new extraction system has been developed for analysis of stable isotopes (δ13CO and δC18O) of atmospheric carbon monoxide from ice core and atmospheric air samples. This system has been designed to measure relatively small sample sizes (80 cc STP of air) to accommodate the limited availability of ice core samples. Trapped air is extracted from ice core samples via melting in a glass vacuum chamber. This air is expanded into a glass expansion loop and then compressed into the sample loop of a Reducing Gas Detector (Peak Laboratories, Peak Performer 1 RCP) for the CO mole fraction measurement. The remaining sample gas will be expelled from the melt vessel into a larger expansion loop via headspace compression for isotopic analysis. The headspace compression will be accomplished by introduction of clean degassed water into the bottom of the melt vessel. Isotopic analysis of the sample gas is done utilizing the Schütze Reagent to convert the carbon monoxide to carbon dioxide (CO2) which is then measured using continuous-flow isotope ratio mass spectrometry (Elementar Americas, IsoPrime 100). A series of cryogenic traps are used to purify the sample air, capture the converted sample CO2, and cryofocus the sample CO2 prior to injection.
Kralev, Stefan; Haag, Benjamin; Spannenberger, Jens; Lang, Siegfried; Brockmann, Marc A.; Bartling, Soenke; Marx, Alexander; Haase, Karl-Konstantin; Borggrefe, Martin; Süselbeck, Tim
2011-01-01
Background Treatment of coronary bifurcation lesions remains challenging, beyond the introduction of drug eluting stents. Dedicated stent systems are available to improve the technical approach to the treatment of these lesions. However dedicated stent systems have so far not reduced the incidence of stent restenosis. The aim of this study was to assess the expansion of the Multi-Link (ML) Frontier™ stent in human and porcine coronary arteries to provide the cardiologist with useful in-vitro information for stent implantation and selection. Methodology/Principal Findings Nine ML Frontier™ stents were implanted in seven human autopsy heart samples with known coronary artery disease and five ML Frontier™ stents were implanted in five porcine hearts. Proximal, distal and side branch diameters (PD, DD, SBD, respectively), corresponding opening areas (PA, DA, SBA) and the mean stent length (L) were assessed by micro-computed tomography (micro-CT). PD and PA were significantly smaller in human autopsy heart samples than in porcine heart samples (3.54±0.47 mm vs. 4.04±0.22 mm, p = 0.048; 10.00±2.42 mm2 vs. 12.84±1.38 mm2, p = 0.034, respectively) and than those given by the manufacturer (3.54±0.47 mm vs. 4.03 mm, p = 0.014). L was smaller in human autopsy heart samples than in porcine heart samples, although data did not reach significance (16.66±1.30 mm vs. 17.30±0.51 mm, p = 0.32), and significantly smaller than that given by the manufacturer (16.66±1.30 mm vs. 18 mm, p = 0.015). Conclusions/Significance Micro-CT is a feasible tool for exact surveying of dedicated stent systems and could make a contribution to the development of these devices. The proximal diameter and proximal area of the stent system were considerably smaller in human autopsy heart samples than in porcine heart samples and than those given by the manufacturer. Special consideration should be given to the stent deployment procedure (and to the follow-up) of dedicated stent systems, considering final intravascular ultrasound or optical coherence tomography to visualize (and if necessary optimize) stent expansion. PMID:21814552
Xylan - A potential contaminant for lunar samples and Antarctic meteorites
NASA Astrophysics Data System (ADS)
Wright, I. P.; Russell, S. S.; Boyd, S. R.; Meyer, C.; Pillinger, C. T.
The possibility that lunar samples have been contaminated by the proprietary lubricant paint known as Xylan, which has been applied to screw threads in dry-N sample processing cabinets at NASA JSC, is considered. From a sample analysis using sealed-tube and stepped combustion, it is argued that the unexpectedly high concentration of organic materials found in EET A79001 is not due to Xylan contamination. It is considered unlikely that previous C and N analyses of lunar samples have been affected by the introduction of Xylan.
Code of Federal Regulations, 2012 CFR
2012-01-01
... ELECTRIC SYSTEM CONSTRUCTION POLICIES AND PROCEDURES General § 1726.10 Introduction. The policies... of loan documents between the Rural Utilities Service (RUS) and its electric borrowers. Unless prior... construction and improvement of electric facilities. Requirements relating to RUS approval of plans and...
Code of Federal Regulations, 2011 CFR
2011-01-01
... ELECTRIC SYSTEM CONSTRUCTION POLICIES AND PROCEDURES General § 1726.10 Introduction. The policies... of loan documents between the Rural Utilities Service (RUS) and its electric borrowers. Unless prior... construction and improvement of electric facilities. Requirements relating to RUS approval of plans and...
Code of Federal Regulations, 2013 CFR
2013-01-01
... ELECTRIC SYSTEM CONSTRUCTION POLICIES AND PROCEDURES General § 1726.10 Introduction. The policies... of loan documents between the Rural Utilities Service (RUS) and its electric borrowers. Unless prior... construction and improvement of electric facilities. Requirements relating to RUS approval of plans and...
Code of Federal Regulations, 2014 CFR
2014-01-01
... ELECTRIC SYSTEM CONSTRUCTION POLICIES AND PROCEDURES General § 1726.10 Introduction. The policies... of loan documents between the Rural Utilities Service (RUS) and its electric borrowers. Unless prior... construction and improvement of electric facilities. Requirements relating to RUS approval of plans and...
Code of Federal Regulations, 2010 CFR
2010-01-01
... ELECTRIC SYSTEM CONSTRUCTION POLICIES AND PROCEDURES General § 1726.10 Introduction. The policies... of loan documents between the Rural Utilities Service (RUS) and its electric borrowers. Unless prior... construction and improvement of electric facilities. Requirements relating to RUS approval of plans and...
Iammarino, Marco; Di Taranto, Aurelia; Cristino, Marianna
2013-10-15
The massive introduction of nitrogen fertilisers, necessary to maximise the global food production, has brought about an increase of the residual amounts of nitrites and nitrates in the products. Notoriously, these compounds may exercise toxic effects. In this work the results obtained from 5years of official controls and monitoring focused on tracing quantifiable amounts of nitrites and nitrates in 1785 samples of meat, dairy, fish products and leafy vegetables are reported. A widespread presence of nitrates at low concentrations in foodstuffs was verified. High concentrations of nitrates were registered in some leafy vegetables and mussels samples, while high nitrites concentrations were registered in some spinach samples. The results confirmed the necessity to develop most controls and suggest the introduction of new legal limits related to some combinations contaminant/matrix. Such new limits may fill legislative gaps that may cause wrong interpretations of the results obtained during official controls. Copyright © 2012 Elsevier Ltd. All rights reserved.
River Chemistry and Solute Flux in Yellowstone National Park
Hurwitz, Shaul; Eagan, Sean; Heasler, Henry; Mahony, Dan; Huebner, Mark A.; Lowenstern, Jacob B.
2007-01-01
Introduction The Yellowstone Volcano Observatory (YVO) was established to 'To strengthen the long-term monitoring of volcanic and earthquake unrest in the Yellowstone National Park region'. Yellowstone National Park is underlain by a voluminous magmatic system overlain by the most active hydrothermal system on Earth. Tracking changes in water and gas chemistry is of great importance because anomalous fluxes might signal one of the earliest warnings of volcanic unrest. Because of the tremendous number, chemical diversity, and large aerial coverage of Yellowstone's thermal features, it remains daunting to monitor individual features that might serve as proxies for anomalous activity in the hydrothermal system. Sampling rivers provides some advantages, because they integrate chemical fluxes over a very large area and therefore, river fluxes may reveal large-scale spatial patterns (Hurwitz et al., 2007). In addition, based on the application of the chloride-enthalpy method (Fournier, 1979), quantifying chloride flux in rivers provides an estimate of the total heat discharge from the Yellowstone volcanic system (Norton and Friedman 1985; Fournier, 1989; Friedman and Norton, in press). Intermittent sampling of the large rivers draining Yellowstone National Park began in the 1960's (Fournier et al., 1976) and continuous sampling has been carried out since water year (1 October - 30 September) 1983 excluding water years 1995 and 1996 (Norton and Friedman, 1985, 1991; Friedman and Norton, 1990, 2000, 2007). Between 1983 and 2001 only Cl concentrations and fluxes were determined. Starting in water year 2002, the concentrations and fluxes of other anions of possible magmatic origin (F-, Br-, HCO3- , and SO42-) were also determined, and several new sampling sites were established (Hurwitz et al., 2007). The ongoing sampling and analysis of river solute flux is a key component in the current monitoring program of YVO, and it is a collaboration between the U.S. Geological Survey and Yellowstone National Park.
Li, Ming; Hu, Bin; Li, Jianqiang; Chen, Rong; Zhang, Xie; Chen, Huanwen
2009-09-15
A homemade novel nanoextractive electrospray ionization (nanoEESI) source has been characterized for in situ mass spectrometric analysis of ambient samples without sample pretreatment. The primary ions generated using a nanospray emitter interact with the neutral sample plume created by manually nebulizing liquid samples, allowing production of the analyte ions in the spatial cross section of the nanoEESI source. The performance of nanoEESI is experimentally investigated by coupling the nanoEESI source to a commercial LTQ mass spectrometer for rapid analysis of various ambient samples using positive/negative ion detection modes. Compounds of interest in actual samples such as aerosol drug preparations, beverages, milk suspensions, farmland water, and groundwater were unambiguously detected using tandem nanoEESI ion trap mass spectrometry. The limit of detection was low picogram per milliliter levels for the compounds tested. Acceptable relative standard deviation (RSD) values (5-10%) were obtained for direct measurement of analytes in complex matrixes, providing linear dynamic signal responses using manual sample introduction. A single sample analysis was completed within 1.2 s. Requiring no sheath gas for either primary ion production or neutral sample introduction, the nanoEESI has advantages including readiness for miniaturization and integration, simple maintenance, easy operation, and low cost. The experimental data demonstrate that the nanoEESI is a promising tool for high-throughput, sensitive, quantitative, in situ analysis of ambient complex samples, showing potential applications for in situ analysis in multiple disciplines including but not limited to pharmaceutical analysis, food quality control, pesticides residue detection, and homeland security.
Schrempft, Stephanie; van Jaarsveld, Cornelia H.M.; Fisher, Abigail; Wardle, Jane
2013-01-01
Objective To identify family and infant characteristics associated with timing of introduction of two food types: core foods (nutrient-dense) and non-core foods (nutrient-poor) in a population-based sample of mothers and infants. Method Participants were 1861 mothers and infants from the Gemini twin birth cohort (one child per family). Family and infant characteristics were assessed when the infants were around 8 months old. Timing of introducing core and non-core foods was assessed at 8 and 15 months. As the distributions of timing were skewed, three similar-sized groups were created for each food type: earlier (core: 1–4 months; non-core: 3–8 months), average (core: 5 months; non-core: 9–10 months), and later introduction (core: 6–12 months; non-core: 11–18 months). Ordinal logistic regression was used to examine predictors of core and non-core food introduction, with bootstrapping to test for differences between the core and non-core models. Results Younger maternal age, lower education level, and higher maternal BMI were associated with earlier core and non-core food introduction. Not breastfeeding for at least 3 months and higher birth weight were specifically associated with earlier introduction of core foods. Having older children was specifically associated with earlier introduction of non-core foods. Conclusion There are similarities and differences in the characteristics associated with earlier introduction of core and non-core foods. Successful interventions may require a combination of approaches to target both food types. PMID:23486509
Genovese, C.; Facciolà, A.; Palamara, M.A.R.; Squeri, R.
2017-01-01
Summary Introduction. Nosocomial infections are one of the greatest problems in public health. Several studies have highlighted the role played by the hospital environment as a possible source of transmission of nosocomial pathogens. Methods. A five-year monitoring of bacterial contamination on healthcare workers hands, surfaces most closely in contact with inpatient wards, operating theatres and "at rest" and "in use" operating theatre air samples. For the samples, we used sterile swabs, contact slides, manual API, and automated VITEK systems for identification. Results. In the five-year period, a total of 9396 samples were collected and analysed. In ward patients, 4398 samplings were carried out with 4.7%, 9.4%, 7%, 10.8% and 7.9% positive results respectively from 2010 to 2014. For hands, 648 samplings were carried out, with a positivity of 40.74%. In operating theatres, 4188 samples were taken, with a positivity of 11.9%. Regarding air in empty and full theatres, 1962 samplings were carried out with a positivity rate equal to 31.9%. The monitoring showed a low rate of contamination with a progressive decrease in the fiveyear period on operating theatres surfaces and hands, while there was an increase in the surgical site wards and in the air of operating rooms. Conclusions. Our investigation has revealed the presence of pathogens on the assessed surfaces and the need for environmental monitoring, which can be a valuable tool for reducing contamination. PMID:28900357
Spatial dynamics of invasion: the geometry of introduced species.
Korniss, Gyorgy; Caraco, Thomas
2005-03-07
Many exotic species combine low probability of establishment at each introduction with rapid population growth once introduction does succeed. To analyse this phenomenon, we note that invaders often cluster spatially when rare, and consequently an introduced exotic's population dynamics should depend on locally structured interactions. Ecological theory for spatially structured invasion relies on deterministic approximations, and determinism does not address the observed uncertainty of the exotic-introduction process. We take a new approach to the population dynamics of invasion and, by extension, to the general question of invasibility in any spatial ecology. We apply the physical theory for nucleation of spatial systems to a lattice-based model of competition between plant species, a resident and an invader, and the analysis reaches conclusions that differ qualitatively from the standard ecological theories. Nucleation theory distinguishes between dynamics of single- and multi-cluster invasion. Low introduction rates and small system size produce single-cluster dynamics, where success or failure of introduction is inherently stochastic. Single-cluster invasion occurs only if the cluster reaches a critical size, typically preceded by a number of failed attempts. For this case, we identify the functional form of the probability distribution of time elapsing until invasion succeeds. Although multi-cluster invasion for sufficiently large systems exhibits spatial averaging and almost-deterministic dynamics of the global densities, an analytical approximation from nucleation theory, known as Avrami's law, describes our simulation results far better than standard ecological approximations.
Chandu, Dilip; Paul, Sudakshina; Parker, Mathew; Dudin, Yelena; King-Sitzes, Jennifer; Perez, Tim; Mittanck, Don W.; Shah, Manali; Glenn, Kevin C.; Piepenburg, Olaf
2016-01-01
Testing for the presence of genetically modified material in seed samples is of critical importance for all stakeholders in the agricultural industry, including growers, seed manufacturers, and regulatory bodies. While rapid antibody-based testing for the transgenic protein has fulfilled this need in the past, the introduction of new variants of a given transgene demands new diagnostic regimen that allows distinguishing different traits at the nucleic acid level. Although such molecular tests can be performed by PCR in the laboratory, their requirement for expensive equipment and sophisticated operation have prevented its uptake in point-of-use applications. A recently developed isothermal DNA amplification technique, recombinase polymerase amplification (RPA), combines simple sample preparation and amplification work-flow procedures with the use of minimal detection equipment in real time. Here, we report the development of a highly sensitive and specific RPA-based detection system for Genuity Roundup Ready 2 Yield (RR2Y) material in soybean (Glycine max) seed samples and present the results of studies applying the method in both laboratory and field-type settings. PMID:27314015
Three countries' experience with Norplant introduction.
Hardee, K; Balogh, S; Villinski, M T
1997-09-01
Despite international efforts to plan for Norplant introduction, the method has drawn the attention of critics of family planning programmes, and has raised several issues for debate since it was introduced into family planning programmes. The experiences of three countries with the introduction of Norplant highlight some of the unique features of the method that have affected its introduction. Indonesia, Bangladesh and the United States represent diverse cultural settings and systems of family planning provision. Experience in each country has highlighted the need to focus on quality of care for clients, most notably the need for good counselling and attention to removal as well as insertion. The cost of Norplant also has influenced its introduction in each country. Another issue includes the need to work with women's health advocacy groups, which is illustrated particularly in Bangladesh. Finally, the role of litigation in the United States, and its potential role in influencing Norplant introduction in other countries, is discussed. These three countries' experience illustrate the importance of understanding the programmatic context of contraceptive introduction.
ERIC Educational Resources Information Center
Chow, Henry P. H.
2010-01-01
Introduction: University students need to cope with a complex new life role and to achieve academic success. This article explores the academic performance and psychological well-being among university students in a western Canadian city. Method: Using a convenience sample, a total of 501 undergraduate students in Regina, Saskatchewan took part in…
Cross-Cultural Comparison of Anxiety Symptoms in Colombian and Australian Children
ERIC Educational Resources Information Center
Amaya, Andrea Crane; Campbell, Marilyn
2010-01-01
Introduction: This cross-cultural study compared both the symptoms of anxiety and their severity in a community sample of children from Colombia and Australia. Method: The sample comprised 516 children (253 Australian children and 263 Colombian children), aged 8 to 12-years-old. The Spence Children's Anxiety Scale (SCAS) was used to measure both…
Introduction to Sample Size Choice for Confidence Intervals Based on "t" Statistics
ERIC Educational Resources Information Center
Liu, Xiaofeng Steven; Loudermilk, Brandon; Simpson, Thomas
2014-01-01
Sample size can be chosen to achieve a specified width in a confidence interval. The probability of obtaining a narrow width given that the confidence interval includes the population parameter is defined as the power of the confidence interval, a concept unfamiliar to many practitioners. This article shows how to utilize the Statistical Analysis…
ERIC Educational Resources Information Center
Consumer Dynamics Inc., Rockville, MD.
This module, one of 25 on vocational education training for careers in environmental health occupations, contains self-instructional materials on calibrating a respirable dust sampling device. Following guidelines for students and instructors and an introduction that explains what the student will learn, are three lessons: (1) naming each part of…
Mukhopadhya, Indrani; Murdoch, Heather; Berry, Susan; Hunt, Alison; Iturriza-Gomara, Miren; Smith-Palmer, Alison; Cameron, J Claire; Hold, Georgina L
2017-01-03
Rotaviruses (RV) are the leading cause of gastroenteritis in children less than five years of age worldwide. Rotarix®, a live attenuated monovalent vaccine containing a RV strain of G1P[8] specificity has been included in the childhood immunisation schedule from June 2013 in Scotland. This study aimed to characterise the prevalent RV strains in Scotland before and after the introduction of the RV vaccine. RV positive faecal samples from Scottish virology laboratories covering the years 2012-2015 were genotyped. Viral RNA was extracted from faecal suspensions. VP7 and VP4 gene specific primers were used for multiplex hemi-nested PCRs and sequencing. Mann-Whitney U test and Chi-square test were used for statistical comparison. There was a decrease in RV positive samples from the Scottish virology laboratories from 7409 samples in the pre-vaccination years (2009-2013) to 760 in 2014-2015, with an annual reduction of RV infections by 74.4% (RR-3.95; 95%-CI, 3.53-4.42, p<0.001). 362 samples from the pre-vaccination period and 278 samples from the post-vaccination were genotyped. There was a drop in prevalence of G1P[8] strains (72.1%, 95%-CI, 67.42-76.33 to 15%, 95%-CI, 11.38-19.79) after introduction of the vaccine. In the post-vaccination period G2P[4] was the dominant strain in Scotland (21.9%, 95%-CI, 17.48-27.17) with increase in G9P[8] (12.9%, 95%-CI, 9.50-7.41), G12P[8] (12.2%, 95%-CI, 8.89-16.60) and G3P[8] (11.9%, 95%-CI, 8.58-16.20) infections. Phylogenetic analysis of the VP7 and VP4 genes showed no major differences between the pre and post-vaccination G1P[8] strains. This laboratory based surveillance study shows significant reduction in reported RV cases and a shift in proportion from G1P[8] to G2P[4] strains after introduction of RV vaccination in Scotland. The genotyping data from a subset of the total reported RV cases will be used to ascertain cross protection against strains and identify vaccine induced RV strain shifts in the years to come. Copyright © 2016 Elsevier Ltd. All rights reserved.
Civil Engineering Work Information Management System (WIMS) Planning Guide,
1985-04-01
WORK INFORMATION MANAGEMENT SYSTEM PLANNING GUIDE l-!O L~ JAUG 0)12 13 "’ ’’’ " " 5 7 2 2 0 0 9 W WTVF--- DISCLAIMER The views and conclusions...y CHAPTER PAGE I INTRODUCTION What is WIMS? --------------------------------- 1I Why Do We Need A WIMS Planning Guide? ------------ I The Target...Administrator ------------------ 21 6 EQUIPMENT AND SUPPLIES Introduction ------------------------------- 22 Magnetic Media Supplies
1990-09-01
I. Introduction .......................................... 1 General Issue .................................. 1 Specific Research Problem...viii APPLICATION OF A MICRO COMPUTER-BASED MANAGEMENT INFORMATION SYSTEM TO IMPROVE THE USAF SERVICE REPORTING PROCESS I. Introduction General Issue...continued Transfer MIP Responsibility ,KNT WETSS0GEFORM UNCLASSIFIED 904 JAUG 19: iRR iRRl UUUUI HOWE271652_ D- FF:MCH INFO: NONE E. iUCH DATA DEF: NONE F
Introduction to the concepts of TELEDEMO and TELEDIMS
NASA Technical Reports Server (NTRS)
Rice, R. F.; Schlutsmeyer, A. P.
1982-01-01
An introduction to the system concepts: TELEDEMO and TELEDIMS is provided. TELEDEMO is derived primarily from computer graphics and, via incorporation of sophisticated image data compression, enables effective low cost teleconferencing at data rates as low as 1K bit/second using dial-up phone lines. Combining TELEDEMO's powerful capabilities for the development of presentation material with microprocessor-based Information Management Systems (IMS) yields a truly all electronic IMS called TELEDIMS.
Clinical efficacy of telemedicine in emergency radiotherapy for malignant spinal cord compression.
Hashimoto, S; Shirato, H; Kaneko, K; Ooshio, W; Nishioka, T; Miyasaka, K
2001-09-01
The authors developed a Telecommunication-HElped Radiotherapy Planning and Information SysTem (THERAPIST), then estimated its clinical benefit in radiotherapy in district hospitals where consultation with the university hospital was required. The system consists of a personal computer with an image scanner and a digital camera, set up in district hospitals and directly connected via ISDN to an image server, and a treatment planning device set up in a university hospital. Image data and consultative reports are sent to the server. Radiation oncologists at the university hospital determine a treatment schedule and verify actual treatment fields. From 1998 to 1999, 12 patients with malignant spinal cord compression (MSCC) were treated by emergency radiotherapy with the help of this system. Image quality, transmission time, and cost benefit also were satisfactory for clinical use. The mean time between the onset of symptoms and the start of radiotherapy was reduced significantly from 7.1 days to 0.8 days (P < .05) by the introduction of the system. Five of 6 nonambulant patients became ambulant after the introduction of THERAPIST compared with 2 of 8 before the introduction of THERAPIST. The treatment outcome was significantly better after the introduction of the system (P < .05), and suggested to be beyond the international standard. The telecommunication-helped radiotherapy and information system was useful in emergency radiotherapy in district hospitals for patients with MSCC for whom consultation with experienced radiation oncologists at a university hospital was required.
Hjerpe, Per; Boström, Kristina Bengtsson; Lindblad, Ulf; Merlo, Juan
2012-12-01
To investigate the impact on ICD coding behaviour of a new case-mix reimbursement system based on coded patient diagnoses. The main hypothesis was that after the introduction of the new system the coding of chronic diseases like hypertension and cancer would increase and the variance in propensity for coding would decrease on both physician and health care centre (HCC) levels. Cross-sectional multilevel logistic regression analyses were performed in periods covering the time before and after the introduction of the new reimbursement system. Skaraborg primary care, Sweden. All patients (n = 76 546 to 79 826) 50 years of age and older visiting 468 to 627 physicians at the 22 public HCCs in five consecutive time periods of one year each. Registered codes for hypertension and cancer diseases in Skaraborg primary care database (SPCD). After the introduction of the new reimbursement system the adjusted prevalence of hypertension and cancer in SPCD increased from 17.4% to 32.2% and from 0.79% to 2.32%, respectively, probably partly due to an increased diagnosis coding of indirect patient contacts. The total variance in the propensity for coding declined simultaneously at the physician level for both diagnosis groups. Changes in the healthcare reimbursement system may directly influence the contents of a research database that retrieves data from clinical practice. This should be taken into account when using such a database for research purposes, and the data should be validated for each diagnosis.
An Introduction to Electrical Breakdown in Dielectrics
1985-04-01
PROJECT TASK WORK UNIT ELEMENT NO. NO. NO. NO. 11TI TL E ’tniclude Security Classification) AN INTRODUCTION TO ELECTRICAL 1PERSONAL AUTHOR(S...find themselves working in the area without the benefit of formal coursework. inAlthough the title of the course was High Voltage Engineer- inI titled...this work , "An Introduction to Electrical Breakdown * Phenomena," because breakdown may occur at low voltages when spacecraft systems are considered
2012-08-08
Research, Fort Sam Houston, San Antonio, Texas, United States of America Abstract Introduction: The recent literature suggests that chronic wound...Introduction The management and treatment of chronic wounds continues to be a significant burden on the healthcare system [1–6]. The importance of bacterial...8, 2012 14. ABSTRACT Introduction: The recent literature suggests that chronic wound biofilms often consist of multiple bacterial species. However
1974-10-01
jet exhaust, m (ft) Ro radius of engine exhaust, m (ft) 1. INTRODUCTION free deg S wing area, m2 (ft2) t time, see T Thrust, N (lb) u...dimensional potential flow method to lift prediction for a wing with internally blown flaps is described. INTRODUCTION The objectives of this paper are...twofold. The first is to provide an introduction to this session on research into the aerodynamics of powered high lift systems. This will be
Geraghty, M; Glynn, F; Amin, M; Kinsella, J
2008-03-01
Non-attendance at out-patient clinics is a seemingly intractable problem, estimated to cost 65 pounds sterling (97 euros) per incident. This results in under-utilisation of resources and prolonged waiting lists. In an effort to reduce out-patient clinic non-attendance, our ENT department, in conjunction with the information and communication technology department, instigated the use of a mobile telephone short message service ('text') reminder, to be sent out to each patient three days prior to their out-patient clinic appointment. To audit non-attendance rates at ENT out-patient clinics following the introduction of a text reminder system. Retrospective review. Non-attendance at our institution's ENT out-patient clinics was audited, following introduction of a text message reminder system in August 2003. Rates of non-attendance were compared for the text message reminder group and a historical control group. Before the introduction of the text message reminder system, the mean rate of non-attendance was 33.6 per cent. Following the introduction of the system, the mean rate of non-attendance reduced to 22 per cent. Sending text message reminders is a simple and cost-effective way to improve non-attendance at ENT out-patient clinics.
Xu, Zhongqi; Doi, Takayuki; Timerbaev, Andrei R; Hirokawa, Takeshi
2008-10-19
A transient isotachophoresis-capillary electrophoresis (tITP-CE) system for the determination of minor inorganic anions in saliva is described. The complete separation and quantification of bromide, iodide, nitrate, nitrite, and thiocyanate has been achieved with only centrifugation and dilution of the saliva sample. In-line tITP preconcentration conditions, created by introduction of the plugs of 5 mM dithionic acid (leading electrolyte) and 10 mM formic acid (terminating electrolyte) before and after the sample zone, respectively, allowed the limits of direct UV absorption detection (at 200 nm) to be up to 50-fold improved as compared with CE without tITP. As a result, nitrate and thiocyanate were still detectable at 4.6 and 3.8 microgl(-1), respectively, in 1000 times diluted saliva. The daily variations of anionic concentrations in saliva samples taken from a smoking health volunteer were discussed based on the results of tITP-CE analysis. It was confirmed that the thiocyanate concentration in saliva noticeably increased after smoking. This is apparently the first report on simultaneous quantification of more than four anionic salivary constituents using CE.
Jakubec, Petr; Bancirova, Martina; Halouzka, Vladimir; Lojek, Antonin; Ciz, Milan; Denev, Petko; Cibicek, Norbert; Vacek, Jan; Vostalova, Jitka; Ulrichova, Jitka; Hrbac, Jan
2012-08-15
This work describes the method for total antioxidant capacity (TAC) and/or total content of phenolics (TCP) analysis in wines using microdialysis online-coupled with amperometric detection using a carbon microfiber working electrode. The system was tested on 10 selected wine samples, and the results were compared with total reactive antioxidant potential (TRAP), oxygen radical absorbance capacity (ORAC), and chemiluminescent determination of total antioxidant capacity (CL-TAC) methods using Trolox and catechin as standards. Microdialysis online-coupled with amperometric detection gives similar results to the widely used cyclic voltammetry methodology and closely correlates with ORAC and TRAP. The problem of electrode fouling is overcome by the introduction of an electrochemical cleaning step (1-2 min at the potential of 0 V vs Ag/AgCl). Such a procedure is sufficient to fully regenerate the electrode response for both red and white wine samples as well as catechin/Trolox standards. The appropriate size of microdialysis probes enables easy automation of the electrochemical TAC/TCP measurement using 96-well microtitration plates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burnett, M.L.W.; Neal, D.; Uchtman, R.
1997-12-31
Approximately 108 of the Hazardous Air Pollutants (HAPs) specified in the 1990 Clean Air Act Amendments are classified as volatile organic compounds (VOCs). Of the 108 VOCs, nearly 35% are oxygenated or polar compounds. While more than one sample introduction technique exists for the analysis of these air toxics, SUMMA{reg_sign} canister sampling is suitable for the most complete range of analytes. A broad concentration range of polar and non-polar species can be analyzed from canisters. A new canister autosampler, the Tekmar AUTOCan{trademark} Elite autosampler, has been developed which incorporates the autosampler and concentrator into a single unit. Analysis of polarmore » and non-polar VOCs has been performed. This paper demonstrates adherence to the technical acceptance objectives outlined in the TO-15 methodology including initial calibration, daily calibration, blank analysis, method detection limits and laboratory control samples. The analytical system consists of a Tekmar AUTOCan{trademark} Elite autosampler interfaced to a Hewlett Packard{reg_sign} 5890/5972 MSD.« less
Rapid identification of bacteria with miniaturized pyrolysis/GC analysis
NASA Astrophysics Data System (ADS)
Morgan, Catherine H.; Mowry, Curtis; Manginell, Ronald P.; Frye-Mason, Gregory C.; Kottenstette, Richard J.; Lewis, Patrick
2001-02-01
Identification of bacteria and other biological moieties finds a broad range of applications in the environmental, biomedical, agricultural, industrial, and military arenas. Linking these applications are biological markers such as fatty acids, whose mass spectral profiles can be used to characterize biological samples and to distinguish bacteria at the gram-type, genera, and even species level. Common methods of sample analysis require sample preparation that is both lengthy and labor intensive, especially for whole cell bacteria. The background technique relied on here utilizes chemical derivatization of fatty acids to the more volatile fatty acid methyl esters (FAMEs), which can be separated on a gas chromatograph column or input directly into a mass spectrometer. More recent publications demonstrate improved sample preparation time with in situ derivatization of whole bacterial samples using pyrolysis at the inlet; although much faster than traditional techniques, these systems still rely on bench-top analytical equipment and individual sample preparation. Development of a miniaturized pyrolysis/GC instrument by this group is intended to realize the benefits of FAME identification of bacteria and other biological samples while further facilitating sample handling and instrument portability. The technologies being fabricated and tested have the potential of achieving pyrolysis and FAME separation on a very small scale, with rapid detection time (1-10 min from introduction to result), and with a modular sample inlet. Performance results and sensor characterization will be presented for the first phase of instrument development, encompassing the microfabricated pyrolysis and gas chromatograph elements.
NASA Astrophysics Data System (ADS)
Omagari, Yuko; Sugihara, Hideharu; Tsuji, Kiichiro
This paper evaluates the economic impact of the introduction of customer-owned Thermal Storage Air-conditioning (TSA) systems, in an electricity market, from the viewpoint of the load service entity. We perform simulations on the condition that several thousand customers install TSA systems and shift peak demand in an electricity market by one percent. Our numerical results indicate that the purchase cost of the LSE was reduced through load management of customers with TSA systems. The introduction of TSA systems also reduced the volatility of market clearing price and reduced the whole-trade cost in an electricity market.
NASA Astrophysics Data System (ADS)
Osetkovsky, I. V.; Kozyrev, N. A.; Kryukov, R. E.; Usoltsev, A. A.; Gusev, A. I.
2017-09-01
The effect of introduction of cobalt in the charge of the flux cored wire of Fe-C-Si-Mn-Cr-Ni-Mo-V system operating under abrasive and abrasive-shock loads is studied. In the laboratory conditions samples of flux cored wires were made, deposition was performed, the effect of cobalt on the hardness and the degree of wear was evaluated, metallographic studies were carried out. The influence of cobalt introduced into the charge of the flux cored wire of Fe-C-Si-Mn-Cr-Ni-Mo-V system on the structure, nature of nonmetallic inclusions, hardness and wear resistance of the weld metal was studied. In the laboratory conditions samples flux cored wire were made using appropriate powdered materials. As a carbon-fluorine-containing material dust from gas cleaning units of aluminum production was used. In the course of the study the chemical composition of the weld metal was determined, metallographic analysis was performed, mechanical properties were determined. As a result of the metallographic analysis the size of the former austenite grain, martensite dispersion in the structure of the weld metal, the level of contamination with its nonmetallic inclusions were established.
Outbreak or illusion: consequences of 'improved' diagnostics for gonorrhoea.
Bennett, Amy; Jeffery, Katie; O'Neill, Eunan; Sherrard, Jackie
2017-06-01
The sexual health service in Oxford introduced gonorrhoea nucleic amplification acid testing using the BD Viper XTR™ System. For practical reasons, a confirmatory nucleic amplification acid testing using a different platform was not used initially. Following the introduction of nucleic amplification acid testing, the rates of gonorrhoea increased threefold. Concerns were raised that this increase represented an outbreak. A retrospective review of cases over six months suggested that there may have been a number of false-positive results. A prospective study was then undertaken over six months, where all gonorrhoea positive samples were sent for confirmatory testing. This evaluation of all gonorrhoea cases in an English county found that the overall presumptive false-positive rates for gonorrhoea nucleic amplification acid testing using BD Viper XTR™ in our population are significant at 27% of female samples, 13.2% of heterosexual male samples, 3.5% of anogenital multiple site men who have sex with men samples and 62.8% of pharyngeal only men who have sex with men samples. The data demonstrate the need for confirmatory testing using a second nucleic acid target, as per BASHH/Public Health England guidelines, especially in low-prevalence settings and extragenital sites, due to cross-reactivity with commensal Neisseria species and low positive predictive values.
Classification of ductal carcinoma in situ by gene expression profiling
Hannemann, Juliane; Velds, Arno; Halfwerk, Johannes BG; Kreike, Bas; Peterse, Johannes L; van de Vijver, Marc J
2006-01-01
Introduction Ductal carcinoma in situ (DCIS) is characterised by the intraductal proliferation of malignant epithelial cells. Several histological classification systems have been developed, but assessing the histological type/grade of DCIS lesions is still challenging, making treatment decisions based on these features difficult. To obtain insight in the molecular basis of the development of different types of DCIS and its progression to invasive breast cancer, we have studied differences in gene expression between different types of DCIS and between DCIS and invasive breast carcinomas. Methods Gene expression profiling using microarray analysis has been performed on 40 in situ and 40 invasive breast cancer cases. Results DCIS cases were classified as well- (n = 6), intermediately (n = 18), and poorly (n = 14) differentiated type. Of the 40 invasive breast cancer samples, five samples were grade I, 11 samples were grade II, and 24 samples were grade III. Using two-dimensional hierarchical clustering, the basal-like type, ERB-B2 type, and the luminal-type tumours originally described for invasive breast cancer could also be identified in DCIS. Conclusion Using supervised classification, we identified a gene expression classifier of 35 genes, which differed between DCIS and invasive breast cancer; a classifier of 43 genes could be identified separating between well- and poorly differentiated DCIS samples. PMID:17069663
Alexander, C L; Shankland, G S; Carman, W; Williams, C
2011-05-01
Dermatophytes are the major cause of superficial mycoses in samples submitted to Clinical Mycology, Glasgow. The most prevalent species is Trichophyton rubrum as identified classically by microscopy and culture. Recent advances in polymerase chain reaction (PCR) technology were examined for the feasibility of introducing a T. rubrum real-time PCR assay into a routine diagnostic service. To improve the diagnostic mycology service by the introduction of a real-time PCR test for T. rubrum. The DNA from 4972 nail and skin samples was obtained using the Qiagen QIAsymphony automated extractor. This DNA was subjected to real-time PCR using T. rubrum-specific primers and a probe. During phase 1 of the study, 862 samples were analysed; 446 of 470 specimens that grew T. rubrum were detected by PCR. Out of 4110 samples analysed during phase 2, 753 T. rubrum infections were diagnosed and reported within 72 h. A total of 3357 samples were negative for a fungal infection by PCR and microscopy; these were also reported within 72 h. A vast reduction in the turnaround times can be achieved using this technique as opposed to classical methods. Samples which are PCR negative but microscopy positive are still subjected to culture. Screening samples for their suitability for PCR prior to processing eliminates the application of PCR for T. rubrum on inappropriate samples such those from the scalp or pityriasis versicolor. © 2011 The Authors. BJD © 2011 British Association of Dermatologists.
NASA Astrophysics Data System (ADS)
Pravdivtseva, O.; Krot, A. N.; Hohenberg, C. M.
2018-04-01
The I-Xe system was studied in a ferromagnetic sample separated from the Orgueil CI carbonaceous chondrite with a hand-held magnet and in two magnetite samples, one chemically separated before and the other one after neutron irradiation. This work was done in order to investigate the effects of chemical separation by LiCl and NaOH on the I-Xe system in magnetite. Our test demonstrated that the chemical separation of magnetite before irradiation using either LiCl or NaOH, or both, does not contaminate the sample with iodine and thus cannot lead to erroneous I-Xe ages due to introduction of uncorrelated 128∗Xe. The I-Xe ages of two Orgueil magnetite samples are mutually consistent within experimental uncertainties and, when normalized to an absolute time scale with the reevaluated Shallowater aubrite standard, place the onset of aqueous alteration on the CI parent body at 4564.3 ± 0.3 Ma, 2.9 ± 0.3 Ma after formation of the CV Ca-AI-rich inclusions (CAIs). The I-Xe age of the ferromagnetic Orgueil separate is 3.4 Ma younger, corresponding to a closure of the I-Xe system at 4560.9 ± 0.2 Ma. These and previously published I-Xe data for Orgueil (Hohenberg et al., 2000) indicate that aqueous alteration on the CI parent body lasted for at least 5 Ma. Although the two magnetite samples gave indistinguishable I-Xe ages, their temperature release profiles differed. One of the two Orgueil magnetites released less radiogenic Xe than the other, 80% of it corresponding to the low-temperature peak of the release profile, compared to only 6% in case of the second Orgueil magnetite sample. This could be due to the difference in iodine trapping efficiencies for magnetite grains of different morphologies. Alternatively, the magnetite grains with the lower radiogenic Xe concentrations may have formed at a later stage of alteration when iodine in an aqueous solution was depleted.
NASA Technical Reports Server (NTRS)
Dean, Derrick; Haque, Anwar; Vaidya, Uday; Meador, Michael A. (Technical Monitor)
2003-01-01
PMR-type polyimides are regarded as state of the art high temperature polymers, due to their excellent thermo-mechanical properties and thermo-oxidative stability. One of their drawbacks, however is the inability to process them using cost-effective processing methods such as Resin Transfer Molding (RTM) and Resin Film Infusion (RFI). Development of low viscosity, high temperature polymers has been the subject of intense research. Recently, a new generation of low viscosity polyimides were synthesized by the introduction of twisted biphenyl or binapthyl groups into the backbone. This report details the progress for Year 1, which has involved acquiring samples and initiating Phases I and II of the proposed research. Specifically, studies of the process-property relationships of a series of polymers using oligomers based on 2,3,3' ,4'-biphenyltertracarboxylic dianhydride (PBDA) and a mixture of a diamine, BAX and a triamine, 1,3,5-Tris (4-aminophenoxybenzene), TAB, where the amount of TAB was varied have been initiated. The sample containing 10 percent TAB possesses a slightly higher degree of crystalline order versus that of the 20 percent TAB sample, based on x-ray diffraction studies of the b-staged oligomers. Both systems lose all of the crystalline order upon curing, however. The chemorheology has been studied as a function of the TAB content. While the magnitude of the viscosity is essentially the same for both systems, the cure kinetics of the 10 percent TAB system is faster than that for the 20 percent TAB system. The sample exhibits a melting-recrystallization-remelting behavior before the crosslinking commences. Correlation of other kinetic parameters, such as the activation energies for curing, the Tg and mechanical properties to the structure of these systems is underway. Future studies will involve characterization of mechanical and thermal properties of the pure resins and the fabrication of fiber reinforced composites using these materials.
Pseudolinear gradient ultrahigh-pressure liquid chromatography using an injection valve assembly.
Xiang, Yanqiao; Liu, Yansheng; Stearns, Stanley D; Plistil, Alex; Brisbin, Martin P; Lee, Milton L
2006-02-01
The use of ultrahigh pressures in liquid chromatography (UHPLC) imposes stringent requirements on hardware such as pumps, valves, injectors, connecting tubing, and columns. One of the most difficult components of the UHPLC system to develop has been the sample injector. Static-split injection, which can be performed at pressures up to 6900 bar (100,000 psi), consumes a large sample volume and is very irreproducible. A pressure-balanced injection valve provided better reproducibility, shorter injection time, reduced sample consumption, and greater ease of use; however, it could only withstand pressures up to approximately 1000 bar (15,000 psi). In this study, a new injection valve assembly that can operate at pressures as high as 2070 bar (30,000 psi) was evaluated for UHPLC. This assembly contains six miniature electronically controlled needle valves to provide accurate and precise volumes for introduction into the capillary LC column. It was found that sample volumes as small as several tenths of a nanoliter can be injected, which are comparable to the results obtained from the static-split injector. The reproducibilities of retention time, efficiency, and peak area were investigated, and the results showed that the relative standard deviations of these parameters were small enough for quantitative analyses. Separation experiments using the UHPLC system with this new injection valve assembly showed that this new injector is suitable for both isocratic and gradient operation modes. A newly designed capillary connector was used at a pressure as high as 2070 bar (30,000 psi).
Low gamma counting for measuring NORM/TENORM with a radon reducing system
NASA Astrophysics Data System (ADS)
Paschoa, Anselmo S.
2001-06-01
A detection system for counting low levels of gamma radiation was built by upgrading an existing rectangular chamber made of 18 metric tonne of steel fabricated before World War II. The internal walls, the ceiling, and the floor of the chamber are covered with copper sheets. The new detection system consists of a stainless steel hollow cylinder with variable circular apertures in the cylindrical wall and in the base, to allow introduction of a NaI (Tl) crystal, or alternatively, a HPGe detector in its interior. This counting system is mounted inside the larger chamber, which in turn is located in a subsurface air-conditioned room. The access to the subsurface room is made from a larger entrance room through a tunnel plus a glass anteroom to decrease the air-exchange rate. Both sample and detector are housed inside the stainless steel cylinder. This cylinder is filled with hyper pure nitrogen gas, before counting a sample, to prevent radon coming into contact with the detector surface. As a consequence, the contribution of the 214Bi photopeaks to the background gamma spectra is minimized. The reduction of the gamma radiation background near the detector facilitates measurement of naturally occurring radioactive materials (NORM), and/or technologically enhanced NORM (TENORM), which are usually at concentration levels only slightly higher than those typically found in the natural radioactive background.
Scott, David E.; Willis, Sean D.; Gabbert, Seth; Johnson, Dave A.; Naylor, Erik; Janle, Elsa M.; Krichevsky, Janice E.; Lunte, Craig E.; Lunte, Susan M.
2015-01-01
The development of an on-animal separation-based sensor that can be employed for monitoring drug metabolism in a freely roaming sheep is described. The system consists of microdialysis sampling coupled directly to microchip electrophoresis with electrochemical detection (MD-ME-EC). Separations were accomplished using an all-glass chip with integrated platinum working and reference electrodes. Discrete samples from the microdialysis flow were introduced into the electrophoresis chip using a flow-gated injection approach. Electrochemical detection was accomplished in-channel using a two-electrode isolated potentiostat. Nitrite was separated by microchip electrophoresis using reverse polarity and a run buffer consisting of 50 mM phosphate at pH 7.4. The entire system was under telemetry control. The system was first tested with rats to monitor the production of nitrite following introduction of nitroglycerin into the subdermal tissue using a linear probe. The data acquired using the on-line MD-ME-EC system was compared to that obtained off-line analysis by liquid chromatography with electrochemical detection (LC-EC), using a second microdialysis probe implanted parallel to the first probe in the same animal. The MD-ME-EC device was then used on-animal to monitor the subdermal metabolism of nitroglycerin in sheep. The ultimate goal is to use this device to simultaneously monitor drug metabolism and behavior in a freely roaming animal. PMID:25697221
Choe, Seung-Ah; Min, Hye Sook; Cho, Sung-Il
2017-01-01
Objectives A number of interventions to reduce disparities in maternal health have been introduced and implemented without concrete evidence to support them. In Korea, a universal voucher scheme for antenatal care and birth services was initiated in December 2008 to improve Korea's fertility rate. This study explores the risk of preeclampsia after the introduction of a universal voucher scheme. Methods Population-based cohort data from the National Health Insurance Service-National Sample Cohort (NHIS-NSC) covering 2002-2013 were analysed. A generalized linear mixed model (GLMM) was used to estimate the relationship between the risk of preeclampsia and voucher scheme introduction. Results The annual age-adjusted incidence of preeclampsia showed no significant unidirectional change during the study period. In the GLMM analysis, the introduction of a voucher scheme was associated with a reduced risk of preeclampsia, controlling for potential confounding factors. The interaction between household income level and voucher scheme was not significant. Conclusions for Practice This finding suggests that the introduction of a voucher scheme for mothers is related to a reduced risk of preeclampsia even under universal health coverage.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Introduction. 87.60 Section 87.60 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF AIR... power auxiliary gearbox-mounted components required to drive aircraft systems is not permitted. (e...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Introduction. 87.80 Section 87.80 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF AIR... various operating points representative of engine usage in aircraft. Other smoke measurement systems may...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Introduction. 87.60 Section 87.60 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF AIR... power auxiliary gearbox-mounted components required to drive aircraft systems is not permitted. (e...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Introduction. 87.80 Section 87.80 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF AIR... various operating points representative of engine usage in aircraft. Other smoke measurement systems may...
NASA Technical Reports Server (NTRS)
Mueller, Rob
2005-01-01
General Background and Introduction of Capability Roadmaps Agency Objective. Strategic Planning Transformation. Advanced Planning Organizational Roles. Public Involvement in Strategic Planning. Strategic Roadmaps and Schedule. Capability Roadmaps and Schedule. Purpose of NRC Review. Capability Roadmap Development (Progress to Date)
Ratnam, Kalai Anand; Dominic, P D D; Ramayah, T
2014-08-01
The investments and costs of infrastructure, communication, medical-related equipments, and software within the global healthcare ecosystem portray a rather significant increase. The emergence of this proliferation is then expected to grow. As a result, information and cross-system communication became challenging due to the detached independent systems and subsystems which are not connected. The overall model fit expending over a sample size of 320 were tested with structural equation modelling (SEM) using AMOS 20.0 as the modelling tool. SPSS 20.0 is used to analyse the descriptive statistics and dimension reliability. Results of the study show that system utilisation and system impact dimension influences the overall level of services of the healthcare providers. In addition to that, the findings also suggest that systems integration and security plays a pivotal role for IT resources in healthcare organisations. Through this study, a basis for investigation on the need to improvise the Malaysian healthcare ecosystem and the introduction of a cloud computing platform to host the national healthcare information exchange has been successfully established.
New approach of a transient ICP-MS measurement method for samples with high salinity.
Hein, Christina; Sander, Jonas Michael; Kautenburger, Ralf
2017-03-01
In the near future it is necessary to establish a disposal for high level nuclear waste (HLW) in deep and stable geological formations. In Germany typical host rocks are salt or claystone. Suitable clay formations exist in the south and in the north of Germany. The geochemical conditions of these clay formations show a strong difference. In the northern ionic strengths of the pore water up to 5M are observed. The determination of parameters like K d values during sorption experiments of metal ions like uranium or europium as homologues for trivalent actinides onto clay stones are very important for long term safety analysis. The measurement of the low concentrated, not sorbed analytes commonly takes place by inductively coupled plasma mass spectrometry (ICP-MS). A direct measurement of high saline samples like seawater with more than 1% total dissolved salt content is not possible. Alternatives like sample clean up, preconcentration or strong dilution have more disadvantages than advantages for example more preparation steps or additional and expensive components. With a small modification of the ICP-MS sample introduction system and a home-made reprogramming of the autosampler a transient analysing method was developed which is suitable for measuring metal ions like europium and uranium in high saline sample matrices up to 5M (NaCl). Comparisons at low ionic strength between the default and the transient measurement show the latter performs similarly well to the default measurement. Additionally no time consuming sample clean-up or expensive online dilution or matrix removal systems are necessary and the analysation shows a high sensitivity due to the data processing based on the peak area. Copyright © 2016 Elsevier B.V. All rights reserved.
Re-cycling mercury: the role of stocking non-native fish in high-altitude lakes
NASA Astrophysics Data System (ADS)
Hansson, S. V.; Le Roux, G.; Sonke, J.
2016-12-01
Mercury (Hg) is a globally distributed pollutant that can be carried long distances and be deposited remote from its original source. It is also one of the few natural abundant trace metals that serves no biological purpose, i.e. is highly toxic to humans and other biota. Studies have also shown that Hg-deposition increases with increasing altitude, leading to a higher load of contamination to these already sensitive environments. Any additional sources of Hg to high-altitude aquatic systems are therefore of high concern. Today introduced non-indigenous fish can be found in aquatic systems on all contents, with the exception of Antarctica. However, the social and economic benefits gained by these introductions often weighs against the ecological impacts. E.g. studies have shown that introduction of carnivore fish can lead to alternation of the aquatic food web and introduce pathogens causing population declines or even extinction. Few studies however have looked at the introduction of non-native fish to high altitude aquatic systems in the scope of heavy-metal contamination. By using a combined geochemical and isotopic approach, we therefore study the introduction of brown trout as a potential source of Hg-contamination in three high altitude lakes in the French Pyrenees. We combine analysis of δ13C and δ15N, with tot-Hg and Hg-isotopes in samples of biofilm, invertebrates, common minnow and brow trout and compare these with data from trout bred at a local fish farm, providing the fish used when stocking lakes in the nearby region. Our results show that levels of tot-Hg in trout from our sites surpasses literature values by 5 times or more and that MIF and MDF Hg-isotope signatures shows clear relationship with fish size and with δ15N. However, there is a clear difference in the Hg-isotopic signatures of the wild trout compared to the farmed. Whereas δ202Hg and Δ199Hg-signatures of the wild trout aligns with the onsite food chain (biofilm, plankton, common minnow), the farmed trout show isotopic signatures identical to marine biota, e.g. tuna and dolphin. This is also reflected in the δ15N-signatures where the farmed trout corresponds to trophic levels two steps above those of the wild trout. Drawing on these data we therefore ask; are we recycling mercury and shortcutting the natural Hg-cycle by stocking lakes with farmed fish?
Control of Suspect/Counterfeit and Defective Items
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheriff, Marnelle L.
2013-09-03
This procedure implements portions of the requirements of MSC-MP-599, Quality Assurance Program Description. It establishes the Mission Support Alliance (MSA) practices for minimizing the introduction of and identifying, documenting, dispositioning, reporting, controlling, and disposing of suspect/counterfeit and defective items (S/CIs). employees whose work scope relates to Safety Systems (i.e., Safety Class [SC] or Safety Significant [SS] items), non-safety systems and other applications (i.e., General Service [GS]) where engineering has determined that their use could result in a potential safety hazard. MSA implements an effective Quality Assurance (QA) Program providing a comprehensive network of controls and verification providing defense-in-depth by preventingmore » the introduction of S/CIs through the design, procurement, construction, operation, maintenance, and modification of processes. This procedure focuses on those safety systems, and other systems, including critical load paths of lifting equipment, where the introduction of S/CIs would have the greatest potential for creating unsafe conditions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barlow, P.M.
1996-12-31
In order to maximize the profitability of Longwall mining operations, outbye materials handling systems should be cost effectively engineered to both fully harmonize with cyclical surges in output and to maintain high levels of availability. With the introduction of new Longwall systems into existing mines, the upgrading of outbye haulage to handle peak production from the Longwall panel can prove to be extremely expensive and is often unnecessary. In addition, despite high levels of investment in new equipment, many mines are still failing to achieve planned gains in Longwall productivity due to persistent downtime on outbye haulage routes. This papermore » details the planning, production and engineering considerations necessary to maximize profitability by the introduction of moving car bunker systems to underground haulage layouts. It also examines case studies of recent installations within the North American coal mining industry and charts the significant success being achieved in improving profitability at these mines.« less
Vereecke, P J
1996-09-01
Computerization is no more improvised just like that and the management of computer plans is from now on a matter for methods and approaches which leave nothing to chance. The main purpose of the present work's empirical part is to a priori determine the attitude which will be the one of the nurses toward the implementation of computer aid in the care units that is expected on the short term. So we will have at our disposal pertinent information which will enable the concerned people to efficiently negotiate this change. For the realization of the present study, we built a LIKERT scale of attitude and integrated it within a question paper with nearly 40 questions. This later was submitted to a stratified random sample of 100 nurses in office at the Clinique St-Pierre in Ottignies (Belgium). After a presentation of that hospital's computer position and of observations made in other hospitals, a detailed study protocol specifies all the features of the research. The achieved results show us that the concerned nurses are highly favorable to the implementation of computer aid. The present work sets out and develops very numerous findings expressed in figures as well as relations and correlations between the attitude and certain features of the sample. The realization of the objectives of any care institution--i.e. a better nursing of the patients and a better managing of the care distribution--colldies with the abundance and the complexity of "Information" which is itself conveyed by numerous systems: nursing, medical, operational, managing information system,... Facing such a reality which is sometimes complex and relatively less analysed, this work is an outline reflection on a bibliographical basis, a conceptual approach that puts certain of the Nursing Information System's generalities in a prominent position--but also some of its specifies--themselves mainly brought to light by means of the introduction of computer aid. The reader will also find here a conceptual pattern integrating the various hospital information sub-systems in interaction, as well as a graphical representation of their information and overlap areas. As the reader will see, the information system--which has become an essential notion in today's data processing--is in the heart of the running of any hospital. Hardly unperceptible, the information system, as long as it is not materialized by the computerization project nonetheless represents a major stake which is covetted by the whole hospital contributors.
An introduction to microbiome analysis for human biology applications.
Amato, Katherine R
2017-01-01
Research examining the gut microbiota is currently exploding, and results are providing new perspectives on human biology. Factors such as host diet and physiology influence the composition and function of the gut microbiota, which in turn affects human nutrition, health, and behavior via interactions with metabolism, the immune system, and the brain. These findings represent an exciting new twist on familiar topics, and as a result, gut microbiome research is likely to provide insight into unresolved biological mechanisms driving human health. However, much remains to be learned about the broader ecological and evolutionary contexts within which gut microbes and humans are affecting each other. Here, I outline the procedures for generating data describing the gut microbiota with the goal of facilitating the wider integration of microbiome analyses into studies of human biology. I describe the steps involved in sample collection, DNA extraction, PCR amplification, high-throughput sequencing, and bioinformatics. While this review serves only as an introduction to these topics, it provides sufficient resources for researchers interested in launching new microbiome initiatives. As knowledge of these methods spreads, microbiome analysis should become a standard tool in the arsenal of human biology research. © 2016 Wiley Periodicals, Inc.
An introduction to the spectrum, symmetries, and dynamics of spin-1/2 Heisenberg chains
NASA Astrophysics Data System (ADS)
Joel, Kira; Kollmar, Davida; Santos, Lea F.
2013-06-01
Quantum spin chains are prototype quantum many-body systems that are employed in the description of various complex physical phenomena. We provide an introduction to this subject by focusing on the time evolution of a Heisenberg spin-1/2 chain and interpreting the results based on the analysis of the eigenvalues, eigenstates, and symmetries of the system. We make available online all computer codes used to obtain our data.
Ibañez-Justicia, A; Gloria-Soria, A; den Hartog, W; Dik, M; Jacobs, F; Stroo, A
2017-12-08
Air-borne introduction of exotic mosquitoes to Schiphol airport in the Netherlands has been considered plausible based upon findings of mosquitoes in aircraft cabins during 2008, 2010 and 2011. Beginning in 2013, surveillance efforts at Schiphol had focused on promptly detecting accidental introductions at the airport facilities in order to quickly react and avoid temporary proliferation or establishment of mosquito populations, identify the origin of the introductions, and avoid potential transmission of vector-borne diseases. BG-Mosquitaire mosquito traps were set at the most likely locations for arrival of the invasive Aedes mosquitoes as part of the mosquito monitoring program at Schiphol airport. Samples were collected bi-weekly. Upon detection of exotic specimens, information about the origin of the flights arriving to the particular location at the airport where specimens were captured was requested from airport authorities. The GIS tool Intersect was then used to identify airports of origin common to positive trapping locations during the specific trapping period. Captured Aedes aegypti mosquitoes were subsequently genotyped at 12 highly polymorphic microsatellite markers and compared to a reference database of 79 populations around the world to further narrow down their location of origin. In 2016, six adult yellow fever mosquitoes were captured indoors and outdoors at the airport of Schiphol in the Netherlands confirming, for the first time, air-borne transport of this mosquito vector species into Europe. Mosquitoes were captured during three time periods: June, September and October. Containers carried by aircrafts are considered the most likely pathway for this introduction. GIS analysis and genetic assignment tests on these mosquitoes point to North America or the Middle East as possible origins, but the small sample size prevents us from reliably identifying the geographic origin of this introduction. The arrival of Ae. aegypti mosquitoes to Schiphol airport from flights arriving from overseas, demonstrates the potential risk of international flights to public health as carriers of arthropod vectors of disease. The results strongly suggest that disinsection of containers and their storage compartments inside the aircrafts could contribute to preventing future introductions of mosquito vectors. Invasive mosquito species introduced by aircrafts from overseas could become seasonally established during the warmer months in Europe, or permanently in certain climatically suitable areas for the species, with major consequences for human health.
Direct Liquid Sampling for Corona Discharge Ion Mobility Spectrometry.
Sabo, Martin; Malásková, Michaela; Harmathová, Olga; Hradski, Jasna; Masár, Marián; Radjenovic, Branislav; Matejčík, Štefan
2015-07-21
We present a new technique suitable for direct liquid sampling and analysis by ion mobility spectrometry (IMS). The technique is based on introduction of a droplet stream to the IMS reaction region. The technique was successfully used to detect explosives dissolved in methanol and oil as well as to analyze amino acids and dipeptides. One of the main advantages of this technique is its ability to analyze liquid samples without the requirement of any special solution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wollaber, Allan Benton
This is a powerpoint presentation which serves as lecture material for the Parallel Computing summer school. It goes over the fundamentals of the Monte Carlo calculation method. The material is presented according to the following outline: Introduction (background, a simple example: estimating π), Why does this even work? (The Law of Large Numbers, The Central Limit Theorem), How to sample (inverse transform sampling, rejection), and An example from particle transport.
Martha J.M. Wells; Jerry L. Michael
1987-01-01
Extensive preparation of samples before chromatographic analysis is usually the most time-consuming process in the determination of many organic compounds in environmental matrices. In the past, removal of some organic from aqueous solution was commonly done by liquid/liquid extraction. However, the introduction of stable, covalently bonded reversed-phase sorbents now...
ERIC Educational Resources Information Center
Alberta Dept. of Education, Edmonton.
This document outlines the use of machine-scorable open-ended questions for the evaluation of Physics 30 in Alberta. Contents include: (1) an introduction to the questions; (2) sample instruction sheet; (3) fifteen sample items; (4) item information including the key, difficulty, and source of each item; (5) solutions to items having multiple…
A genetic survey of Salvinia minima in the southern United States
Madeira, Paul T.; Jacono, C.C.; Tipping, Phil; Van, Thai K.; Center, Ted D.
2003-01-01
The genetic relationships among 68 samples of Salvinia minima (Salviniaceae) were investigated using RAPD analysis. Neighbor joining, principle components, and AMOVA analyses were used to detect differences among geographically referenced samples within and outside of Florida. Genetic distances (Nei and Li) range up to 0.48, although most are under 0.30, still relatively high levels for an introduced, clonally reproducing plant. Despite the diversity AMOVA analysis yielded no indication that the Florida plants, as a group, were significantly different from the plants sampled elsewhere in its adventive, North American range. A single, genetically dissimilar population probably exists in the recent (1998) horticultural introduction to Mississippi. When the samples were grouped into 10 regional (but artificial) units and analyzed using AMOVA the between region variance was only 7.7%. Genetic similarity among these regions may indicate introduction and dispersal from common sources. The reduced aggressiveness of Florida populations (compared to other states) may be due to herbivory. The weevil Cyrtobagous salviniae, a selective feeder, is found in Florida but not other states. The genetic similarity also suggests that there are no obvious genetic obstacles to the establishment or efficacy of C. salviniae as a biological control agent on S. minima outside of Florida.
Enhancing faba bean (Vicia faba L.) germplasm for resilience to temperature extremes
USDA-ARS?s Scientific Manuscript database
The Western Regional Plant Introduction Station (WRPIS) is one of the four regional plant introduction stations in the US Department of Agriculture-ARS National Plant Germplasm System (NPGS) with the mission of acquiring, documenting, maintaining, characterizing, evaluating and distributing plant ge...
Mueller, David K.; Spahr, Norman E.
2005-01-01
Introduction: This report is the companion data report for: Nutrients in Streams and Rivers Across the Nation - 1992-2001 (D.K. Mueller and N.E. Spahr, U.S. Geological Survey written commun., 2005). The data contained in this report were collected as part of the National Water-Quality Assessment (NAWQA) Program. Investigations were conducted in 51 large river basins and aquifer systems, which are referred to as 'study units.' Implementation of study-unit investigations were phased so that high-intensity sampling occurred in about one-third of the study units at a time. Investigations in the first 20 study units began in 1991, and stream sampling began in 1992; however, most samples were collected during water years 1993-95. (Water year is defined as the period from October through September and is identified by the year in which it ends.) A second group of 16 study-unit investigations began in 1994, with most of the sampling completed during water years 1996-98. A third group, consisting of 15 study units, began in 1997 with most of the data collected during water years 1999-2001. At some sites, additional sampling continued after the high-intensity time period. Gilliom and others (1995) provide additional information about study-unit sampling design. Additional information about the NAWQA program is available at http://water.usgs.gov/nawqa/index.html.
Evaluation of introduction of the Haemophilus influenzae vaccine in Côte d’Ivoire
Yohou, Kévin Sylvestre; Aka, Nicaise Lepri; Noufe, Soualihou; Douba, Alfred; Assi Assi, Bernard; Dagnan, Simplice N Cho
2016-11-25
Introduction: Côte d’Ivoire introduced the Haemophilus influenzae type b vaccine into the EPI in March 2009. Following this introduction, an evaluation was conducted in 2012 in order to evaluate the vaccine introduction process. Methods: Data collection methods consisted of document review, structured interviews and direct observation. This study collected information from six health region officials, 12 health districts and 36 healthcare institutions. Seventy-two mothers or child carers were also interviewed. Collected data were processed and analysed by Excel, Epi Info and SPSS. Results: A vaccine introduction plan was developed, but was not communicated at the operational level. The planned training for district health care providers was conducted eighteen months after introduction of the vaccine. None of the vaccinating centres had communication support about the new vaccine. Temperature recording was regularly performed in 92% of district deposits and 68% of vaccinating centres. Deteriorated vaccines were observed in 6% of vaccinating centres. Only 3.5% of parents had been informed about introduction of the vaccine. Increased immunization coverage for the third dose of pentavalent vaccine was observed in one half of health districts. Conclusion: Evaluation of the introduction of Haemophilus influenzae type b vaccine highlightsthe strengths and weaknesses of the health system and provides lessons for the introduction of other vaccines into the expanded programme on immunization.
NASA Astrophysics Data System (ADS)
Hinsdale, Taylor; Malik, Bilal H.; Rico-Jimenez, Jose J.; Jo, Javier A.; Maitland, Kristen C.
2016-03-01
We present a wide-field fluorescence lifetime imaging (FLIM) system with optical sectioning by structured illumination microscopy (SIM). FLIM measurements were made using a time gated ICCD camera in conjunction with a pulsed nitrogen dye laser operating at 450 nm. Intensity images were acquired at multiple time delays from a trigger initiated by a laser pulse to create a wide-field FLIM image, which was then combined with three phase SIM to provide optical sectioning. Such a mechanism has the potential to increase the reliability and accuracy of the FLIM measurements by rejecting background intensity. SIM also provides the opportunity to create volumetric FLIM images with the incorporation of scanning mechanisms for the sample plane. We present multiple embodiments of such a system: one as a free space endoscope and the other as a fiber microendoscope enabled by the introduction of a fiber bundle. Finally, we demonstrate the efficacy of such an imaging system by imaging dyes embedded in a tissue phantom.
NASA Technical Reports Server (NTRS)
Rummel, John D.
2001-01-01
Before martian soil and rock samples can be distributed to the research community, the returned materials will initially be quarantined and examined in a proposed BSL-4 containment facility to assure that no putative martian microorganisms or attendant potential biohazards exist. During the initial quarantine, state-of-the-art life detection and biohazard testing of the returned martian samples will be conducted. Life detection, as defined here in regard to Mars sample return missions, is the detection of living organisms and/or materials that have been derived from living organisms that may be present in the sample.
Engineering Design Handbook: Development Guide for Reliability. Part Three. Reliability Prediction
1976-01-01
Populations 4-3 4-7 IFR and DFR Distributions 4-3 CHAPTER 5. SOME ADVANCED MATHEMATICAL TECHNIQUES 5-0 List of Symbols 5-1 5-1 Introduction...Aß,CJE= sets AFyAGSFJBc ~ events that units UA and -\\AAA E{] EB £H T $£ T UB are Failed or Good subsets "of A£,CJ),E s-expected value of...i.e., the sample space is all possible values that can arise. Each value is called a sample point. There are six sample points in the sample space
Barnadas, Céline; Midgley, Sofie E; Skov, Marianne N; Jensen, Lotte; Poulsen, Mille W; Fischer, Thea Kølsen
2017-08-01
The potential for outbreaks due to Enteroviruses (EV) with respiratory tropism, such as EV-D68, and the detection of new and rare EV species C is a concern. These EVs are typically not detected in stool specimens and may therefore be missed by standard EV surveillance systems. Following the North American outbreak of EV-D68 in 2014, Denmark piloted an enhanced EV surveillance system that included the screening of respiratory samples. We aim to report clinical manifestations and phylogenetic descriptions from the rare and emerging EVs identified thereby demonstrating the usefulness of this system. Positive EV samples received through the enhanced non-polio EV pilot surveillance system were characterized by sequencing fragments of VP1, VP2 and VP4 capsid proteins and clinical observations were compiled. Between January 2015 and October 2016, six cases of rare genotypes EV-C104, C105 and C109 and nine cases of EV-D68 were identified. Patients presented with mild to moderately severe respiratory illness; no paralysis occurred. Distinct EV-C104, EV-C109 and EV-D68 sequences argue against a common source of introduction of these genotypes in the Danish population. The enhanced EV surveillance system enabled detection and characterization of rare EVs in Denmark. In order to improve our knowledge of and our preparedness against emerging EVs, public health laboratories should consider expanding their EV surveillance system to include respiratory specimens. Copyright © 2017 Elsevier B.V. All rights reserved.
[A heart function measuring and analyzing instrument based on single-chip microcomputer].
Rong, Z; Liang, H; Wang, S
1999-05-01
An Introduction a measuring and analyzing instrument, based on the single-chip microcomputer, which provides sample gathering, processing, controlling, adjusting, keyboard and printing. All informations are provided and displayed in Chinese.
Hjerpe, Per; Boström, Kristina Bengtsson; Lindblad, Ulf; Merlo, Juan
2012-01-01
Objective To investigate the impact on ICD coding behaviour of a new case-mix reimbursement system based on coded patient diagnoses. The main hypothesis was that after the introduction of the new system the coding of chronic diseases like hypertension and cancer would increase and the variance in propensity for coding would decrease on both physician and health care centre (HCC) levels. Design Cross-sectional multilevel logistic regression analyses were performed in periods covering the time before and after the introduction of the new reimbursement system. Setting Skaraborg primary care, Sweden. Subjects All patients (n = 76 546 to 79 826) 50 years of age and older visiting 468 to 627 physicians at the 22 public HCCs in five consecutive time periods of one year each. Main outcome measures Registered codes for hypertension and cancer diseases in Skaraborg primary care database (SPCD). Results After the introduction of the new reimbursement system the adjusted prevalence of hypertension and cancer in SPCD increased from 17.4% to 32.2% and from 0.79% to 2.32%, respectively, probably partly due to an increased diagnosis coding of indirect patient contacts. The total variance in the propensity for coding declined simultaneously at the physician level for both diagnosis groups. Conclusions Changes in the healthcare reimbursement system may directly influence the contents of a research database that retrieves data from clinical practice. This should be taken into account when using such a database for research purposes, and the data should be validated for each diagnosis. PMID:23130878
Castellanos, Ixchel; Schüttler, Jürgen; Prokosch, Hans-Ulrich; Bürkle, Thomas
2013-09-16
Patient Data Management Systems (PDMS) support clinical documentation at the bedside and have demonstrated effects on completeness of patient charting and the time spent on documentation. These systems are costly and raise the question if such a major investment pays off. We tried to answer the following questions: How do costs and revenues of an intensive care unit develop before and after introduction of a PDMS? Can higher revenues be obtained with improved PDMS documentation? Can we present cost savings attributable to the PDMS? Retrospective analysis of cost and reimbursement data of a 25 bed Intensive Care Unit at a German University Hospital, three years before (2004-2006) and three years after (2007-2009) PDMS implementation. Costs and revenues increased continuously over the years. The profit of the investigated ICU was fluctuating over the years and seemingly depending on other factors as well. We found a small increase in profit in the year after the introduction of the PDMS, but not in the following years. Profit per case peaked at 1039 € in 2007, but dropped subsequently to 639 € per case. We found no clear evidence for cost savings after the PDMS introduction. Our cautious calculation did not consider additional labour costs for IT staff needed for system maintenance. The introduction of a PDMS has probably minimal or no effect on reimbursement. In our case the observed increase in profit was too small to amortize the total investment for PDMS implementation.This may add some counterweight to the literature, where expectations for tools such as the PDMS can be quite unreasonable.
Impact and Effectiveness of Monovalent Rotavirus Vaccine in Armenian Children.
Sahakyan, Gayane; Grigoryan, Svetlana; Wasley, Annemarie; Mosina, Liudmila; Sargsyan, Shushan; Asoyan, Ara; Gevorgyan, Zaruhi; Kocharyan, Karine; Avagyan, Tigran; Lopman, Benjamin; Vanyan, Artavazd; Khactatryan, Sergey; Parashar, Umesh D; Cortese, Margaret M
2016-05-01
The Republic of Armenia was 1 of the 2 earliest countries in the Newly Independent States to introduce rotavirus vaccine into its national immunization program to reduce the burden of rotavirus disease (documented to cause 38% of acute gastroenteritis hospitalizations [AGE] among children aged <5 years). In November 2012, RV1 (Rotarix) was introduced for Armenian infants at ages 6 and 12 weeks. The established active surveillance system at 2 hospitals in the capital, Yerevan, whereby children aged <5 years hospitalized for AGE have stool sample tested for rotavirus antigen, was used to assess trends in rotavirus hospitalizations. Immunization records on children enrolled after vaccine introduction were obtained from clinics, and vaccine effectiveness (VE) was estimated using children with AGE who test negative for rotavirus as controls for the rotavirus-positive cases. Among infants, rotavirus hospitalizations were reduced by 48% within the first year after introduction, and by ≥75% in years 2 and 3 following introduction. Reductions of ≥30% in other young children too old to have been vaccinated suggest additional benefit through indirect protection; overall in year 3, rotavirus hospitalizations were reduced by 69% among children aged <5 years. The overall VE of 2 RV1 doses in protecting against rotavirus hospitalization (any severity) was 62% (95% confidence interval [CI], 36%-77%) among children aged 6-23 months; 68% (95% CI, 24%-86%) among those aged 6-11 months, and 60% (95% CI, 20%-80%) in children aged 12-23 months. Against more severe rotavirus disease, VE was 79% (95% CI, 55%-90%) and similarly high in both age groups. RV1 is effective in young Armenian children and substantially reduced rotavirus hospitalizations shortly after introduction. Published by Oxford University Press for the Infectious Diseases Society of America 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Nelson, B
1994-09-05
The introduction of casemix payment systems into Australia's public hospitals is an inevitability which the Australian Medical Association has now begun to address. A greater involvement of clinicians in the design and implementation of casemix can add substantial quality to these systems. However, there is concern that a proliferation of separate casemix systems may be contrary to overall health policy developments and that governments will not understand the limits of casemix. Recent attempts to include medical payments within a casemix payment system in the private sector faced our united opposition. Finally, special care needs to be taken to ensure that the introduction of a casemix payment system does not further disadvantage access to high quality health care for Aborigines.
NASA Astrophysics Data System (ADS)
Termopoli, Veronica; Famiglini, Giorgio; Palma, Pierangela; Cappiello, Achille; Vandergrift, Gregory W.; Krogh, Erik T.; Gill, Chris G.
2016-02-01
Polycyclic aromatic hydrocarbons (PAHs) are USEPA regulated priority pollutants. Their low aqueous solubility requires very sensitive analytical methods for their detection, typically involving preconcentration steps. Presented is the first demonstrated `proof of concept' use of condensed phase membrane introduction mass spectrometry (CP-MIMS) coupled with direct liquid electron ionization (DEI) for the direct, on-line measurement of PAHs in aqueous samples. DEI is very well suited for the ionization of PAHs and other nonpolar compounds, and is not significantly influenced by the co-elution of matrix components. Linear calibration data for low ppb levels of aqueous naphthalene, anthracene, and pyrene is demonstrated, with measured detection limits of 4 ppb. Analytical response times (t10%-90% signal rise) ranged from 2.8 min for naphthalene to 4.7 min for pyrene. Both intra- and interday reproducibility has been assessed (<3% and 5% RSD, respectively). Direct measurements of ppb level PAHs spiked in a variety of real, complex environmental sample matrices is examined, including natural waters, sea waters, and a hydrocarbon extraction production waste water sample. For these spiked, complex samples, direct PAH measurement by CP-MIMS-DEI yielded minimal signal suppression from sample matrix effects (81%-104%). We demonstrate the use of this analytical approach to directly monitor real-time changes in aqueous PAH concentrations with potential applications for continuous on-line monitoring strategies and binding/adsorption studies in heterogeneous samples.
NASA Astrophysics Data System (ADS)
Roe, H. S. J.; Angel, M. V.; Badcock, J.; Domanski, P.; James, P. T.; Pugh, P. R.; Thurston, M. H.
(i) This paper is an introduction to a series of papers describing the diel migrations and interrelationships of a mesopelagic community in the northeast Atlantic. (ii) The biological and physical background to the sampling area is described. (iii) There was little physical structure in the water column to a depth of 1000 m. (iv) The influence of Mediterranean water was detectable at varying depths between 550 and 800 m during the sampling programme. The possibility of mesoscale activity at these depths is discussed. (v) The sampling programme is described. Using the I.O.S. rectangular midwater trawl, the RMT 1 + 8, one hour samples were taken at 4 depth horizons, 100, 250, 450 and 600 m. Each depth was fished continuously for 48 hr. (vi) Additional non-quantitative surface samples, and surface light measurements were made throughout the RMT 1 + 8 sampling period. (vii) 97 hauls were made and the data for fish, decapod Crustacea, mysids, euphausiids, amphipods, copepods, ostracods, siphonophores, medusae, cteniphores and chaetognaths analysed. (viii) General results in terms of total numbers and numbers of species taken by the RMT 1 and the RMT 8 are described. (ix) The populations at 100 and 250 m showed more diel variation than those at 450 and 600 m, but the proportions of individual species and groups changed continuously at all depths. (x) These changes are due to diel vertical migrations. The migrations of most species only involved a part of their populations.
Aerosol dilution as a simple strategy for analysis of complex samples by ICP-MS.
Barros, Ariane I; Pinheiro, Fernanda C; Amaral, Clarice D B; Lorençatto, Rodolfo; Nóbrega, Joaquim A
2018-02-01
This study investigated the capability of High Matrix Introduction (HMI) strategy for analysis of dialysis solution and urine samples using inductively coupled plasma mass spectrometry. The use of HMI enables the direct introduction of urine samples and dialysis solutions 2-fold diluted with 0.14molL -1 HNO 3 . Bismuth, Ge, Ir, Li, Pt, Rh, Sc and Tl were evaluated as internal standards for Al, Ag, As, Be, Cd, Cr, Pb, Sb, Se, Tl, and Hg determination in dialysis solution and As, Cd, Hg and Pb determination in urine samples. Helium collision cell mode (4.5mLmin -1 ) was efficient to overcome polyatomic interferences in As, Se and Cr determinations. Mercury memory effects were evaluated by washing with 0.12molL -1 HCl or an alkaline diluent solution prepared with n-butanol, NH 4 OH, EDTA, and Triton X-100. This later solution was efficient for avoiding Hg memory effects in 6h of analysis. Linear calibration curves were obtained for all analytes and detection limits were lower than maximum amounts allowed by Brazilian legislations. Recoveries for all analytes in dialysis solutions and urine samples ranged from 82% to 125% and relative standard deviations for all elements and samples were lower than 7%. Analysis of control internal urine samples was in agreement with certified values at 95% confidence level (t-test; p < 0.05). Copyright © 2017 Elsevier B.V. All rights reserved.
Networks - The Air Force’s Newest Weapon Systems
2006-02-17
Force networks. Marshall T. Rose, The Simple Book: An Introduction to Management of TCP/IP based internets, (Englewood Cliffs, New Jersey: Prentice...18 November 2005 19. Rose, Marshall T. The Simple Book: An Introduction to Management of TCP/IP based internets, (Englewood Cliffs, New Jersey
Artificial Intelligence Is for Real: Undergraduate Students Should Know about It.
ERIC Educational Resources Information Center
Liebowitz, Jay
1988-01-01
Discussion of the possibilities of introducing artificial intelligence (AI) into the undergraduate curriculum highlights the introduction of AI in an introduction to information processing course for business students at George Washington University. Topics discussed include robotics, expert systems prototyping in class, and the interdisciplinary…
Atchan, Marjorie; Davis, Deborah; Foureur, Maralyn
2017-02-01
Breastfeeding has many known benefits yet its support across Australian health systems was suboptimal throughout the 20th Century. The World Health Organization launched a global health promotion strategy to help create a 'breastfeeding culture'. Research on the programme has revealed multiple barriers since implementation. To analyse the sociopolitical challenges associated with implementing a global programme into a national setting via an examination of the influences on the early period of implementation of the Baby Friendly Hospital Initiative in Australia. A focused historical document analysis was attended as part of an instrumental case study. A purposeful sampling strategy obtained a comprehensive sample of public and private documents related to the introduction of the BFHI in Australia. Analysis was informed by a 'documents as commentary' approach to gain insight into individual and collective social practices not otherwise observable. Four major themes were identified: "a breastfeeding culture"; "resource implications"; "ambivalent support for breastfeeding and the BFHI" and "business versus advocacy". "A breastfeeding culture" included several subthemes. No tangible support for breastfeeding generally, or the Baby Friendly Hospital Initiative specifically, was identified. Australian policy did not follow international recommendations. There were no financial or policy incentives for BFHI implementation. Key stakeholders' decisions negatively impacted on the Baby Friendly Hospital Initiative at a crucial time in its implementation in Australia. The potential impact of the programme was not realised, representing a missed opportunity to establish and provide sustainable standardised breastfeeding support to Australian women and their families. Copyright © 2016 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.
Ito, Nobuko; Chinzei, Mieko; Fujiwara, Haruko; Usui, Hisako; Hanaoka, Kazuo; Saitoh, Eisho
2006-04-01
Supply, Processing and Distribution system had been introduced to surgical center (the University of Tokyo Hospital) since October of 2002. This system had reduced stock for medicine and materials and decreased medical cost dramatically. We designed some kits for therapeutic drugs related to anesthesia. They were prepared for general anesthesia, epidural and spinal anesthesia, and cardiovascular anesthesia, respectively. One kit had been used for one patient, and new kits were prepared in the anesthesia preparation room by pharmaceutical department staffs. Equipment, for general anesthesia as well as epidural and spinal anesthesia, and central catheter set were also designed and provided for each patient by SPD system. According to the questionnaire of anesthesia residents before and after introduction of SPD system, the time spent for anesthesia preparation had been reduced and 92.3% residents had answered that preparation for anesthesia on the previous day was getting easier. Most of the anesthesia residents had been less stressed after introduction of SPD system. Beside the dramatic economical effect, coordination with SPD system and pharmaceutical department reduced anesthesia preparation time and stress of the staff. Introduction of Support system of SPD to surgical center is important for safe and effective management of operating rooms.
NASA Astrophysics Data System (ADS)
Krogh, E.; Gill, C.; Bell, R.; Davey, N.; Martinsen, M.; Thompson, A.; Simpson, I. J.; Blake, D. R.
2012-12-01
The release of hydrocarbons into the environment can have significant environmental and economic consequences. The evolution of smaller, more portable mass spectrometers to the field can provide spatially and temporally resolved information for rapid detection, adaptive sampling and decision support. We have deployed a mobile platform membrane introduction mass spectrometer (MIMS) for the in-field simultaneous measurement of volatile and semi-volatile organic compounds. In this work, we report instrument and data handling advances that produce geographically referenced data in real-time and preliminary data where these improvements have been combined with high precision ultra-trace VOCs analysis to adaptively sample air plumes near oil and gas operations in Alberta, Canada. We have modified a commercially available ion-trap mass spectrometer (Griffin ICX 400) with an in-house temperature controlled capillary hollow fibre polydimethylsiloxane (PDMS) polymer membrane interface and in-line permeation tube flow cell for a continuously infused internal standard. The system is powered by 24 VDC for remote operations in a moving vehicle. Software modifications include the ability to run continuous, interlaced tandem mass spectrometry (MS/MS) experiments for multiple contaminants/internal standards. All data are time and location stamped with on-board GPS and meteorological data to facilitate spatial and temporal data mapping. Tandem MS/MS scans were employed to simultaneously monitor ten volatile and semi-volatile analytes, including benzene, toluene, ethylbenzene and xylene (BTEX), reduced sulfur compounds, halogenated organics and naphthalene. Quantification was achieved by calibrating against a continuously infused deuterated internal standard (toluene-d8). Time referenced MS/MS data were correlated with positional data and processed using Labview and Matlab to produce calibrated, geographical Google Earth data-visualizations that enable adaptive sampling protocols. This real-time approach has been employed in a moving vehicle to identify and track downwind plumes of fugitive VOC emissions near hydrocarbon upgrading and chemical processing facilities in Fort Saskatchewan, Alberta. This information was relayed to a trailing vehicle, which collected stationary grab samples in evacuated canisters for ultra trace analysis of over seventy VOC analytes. In addition, stationary time series data were collected and compared with grab samples co-located with our sampling line. Spatially and temporally resolved, time referenced MS/MS data for several air contaminants associated with oil and gas processing were processed in real time to produce geospatial data for visualization in Google Earth. This information was used to strategically locate grab samples for high precision, ultra trace analysis.
The costs and effectiveness of large Phase III pre-licensure vaccine clinical trials.
Black, Steven
2015-01-01
Prior to the 1980s, most vaccines were licensed based upon safety and effectiveness studies in several hundred individuals. Beginning with the evaluation of Haemophilus influenzae type b conjugate vaccines, much larger pre-licensure trials became common. The pre-licensure trial for Haemophilus influenzae oligosaccharide conjugate vaccine had more than 60,000 children and that of the seven-valent pneumococcal conjugate vaccine included almost 38,000 children. Although trial sizes for both of these studies were driven by the sample size required to demonstrate efficacy, the sample size requirements for safety evaluations of other vaccines have subsequently increased. With the demonstration of an increased risk of intussusception following the Rotashield brand rotavirus vaccine, this trend has continued. However, routinely requiring safety studies of 20,000-50,000 or more participants has two major downsides. First, the cost of performing large safety trials routinely prior to licensure of a vaccine is very large, with some estimates as high at US$200 million euros for one vaccine. This high financial cost engenders an opportunity cost whereby the number of vaccines that a company is willing or able to develop to meet public health needs becomes limited by this financial barrier. The second downside is that in the pre-licensure setting, such studies are very time consuming and delay the availability of a beneficial vaccine substantially. One might argue that in some situations, this financial commitment is warranted such as for evaluations of the risk of intussusception following newer rotavirus vaccines. However, it must be noted that while an increased risk of intussusception was not identified in large pre-licensure studies, in post marketing evaluations an increased risk of this outcome has been identified. Thus, even the extensive pre-licensure evaluations conducted did not identify an associated risk. The limitations of large Phase III trials have also been demonstrated in efficacy trials. Notably, pre-licensure trials of pneumococcal conjugate severely underestimated their true effect and cost-effectiveness. In fact, in discussions prior to vaccine introduction in the USA for PCV7, the vaccine was said to be not cost-effective and some counseled against its introduction. In reality, following introduction, PCV7 has been shown to be highly cost-effective. In the last decade, new methods have been identified using large linked databases such as the Vaccine Safety Datalink in the USA that allow identification of an increased risk of an event within a few months of vaccine introduction and that can screen for unanticipated very rare events as well. In addition, the availability of electronic medical records and hospital discharge data in many settings allows for accurate assessment of vaccine effectiveness. Given the high financial and opportunity cost of requiring large pre-licensure safety studies, consideration could be given to 'conditional licensure' of vaccines whose delivery system is well characterized in a setting where sophisticated pharmacovigilance systems exist on the condition that such licensure would incorporate a requirement for rapid cycle and other real-time evaluations of safety and effectiveness following introduction. This would actually allow for a more complete and timely evaluation of vaccines, lower the financial barrier to development of new vaccines and thus allow a broader portfolio of vaccines to be developed and successfully introduced.
Introduction of solid food to young infants.
Kuo, Alice A; Inkelas, Moira; Slusser, Wendelin M; Maidenberg, Molly; Halfon, Neal
2011-11-01
Timing of the first introduction of solid food during infancy may have potential effects on life-long health. To understand the characteristics that are associated with the timing of infants' initial exposure to solid foods. The 2000 National Survey of Early Childhood Health (NSECH) was a nationally representative telephone survey of 2,068 parents of children aged 4-35 months, which profiled content and quality of health care for young children. African-American and Latino families were over-sampled. Analyses in this report include bivariate tests and logistic regressions. 62% of parents reported introducing solids to their child between 4-6 months of age. African-American mothers (OR=0.5 [0.3, 0.9]), English-speaking Latino mothers (OR=0.4 [0.2, 0.7]), White mothers with more than high school education (OR=0.5 [0.2, 1.0]), and mothers who breastfed for 4 months or longer (OR=0.4 [0.3, 0.7]) were less likely to introduce solids early. Most parents (92%) of children 4-9 months of age reported that their pediatric provider had discussed introduction of solids with them since the child's birth, and provider discussion of feeding was not associated with the timing of introduction of solids. Although most parents recall discussing the introduction of solid foods with their child's physician, several subgroups of mothers introduce solid foods earlier than the AAP recommendation of 4-6 months. More effective discussion of solid food introduction linked to counseling and support of breastfeeding by the primary health care provider may reduce early introduction of solids.
Introduction of assistive devices: home nurses' practices and beliefs.
Roelands, Marc; Van Oost, Paulette; Depoorter, Anne Marie; Buysse, Ann; Stevens, Veerle
2006-04-01
This paper reports a study describing home nurses' intention and current practices regarding introducing assistive devices, and investigating whether their practice is related to social cognitive factors (attitudes, subjective norms and self-efficacy). Home nurses not only care for patients in particular medical domains, but also educate and guide them towards more independence. Patients with age-related disabilities in mobility and self-care might benefit from the use of assistive devices. A home nurse might be the first and only person to discuss the disability and use of an assistive device. Therefore, home nurses' beliefs about the introduction of assistive devices could affect their daily practices. A cross-sectional study was conducted with a convenience sample of 64 home nurses chosen from a random sample of home nursing departments. The home nurses completed a self-administered questionnaire. The Theory of Planned Behaviour framework was used to develop the social cognitive measures regarding each of the six steps distinguished in the introduction of assistive devices. Home nurses had positive attitudes and high levels of intention, subjective norm and self-efficacy towards most steps of the decision process to introduce assistive devices. In a multiple linear regression analysis, attitude and self-efficacy predicted intention to introduce assistive devices to older clients with disabilities. Intention was correlated to home nurses' current practices. The findings suggest that conditions are present to involve home nurses more explicitly in the introduction of assistive devices to their patients. Social cognitive factors should be taken into account when developing interventions that aim to support home nurses to do this.
Magnetic Resonance Imaging at Ultrahigh Fields
Uğurbil, Kamil
2014-01-01
Since the introduction of 4 T human systems in three academic laboratories circa 1990, rapid progress in imaging and spectroscopy studies in humans at 4 T and animal model systems at 9.4 T have led to the introduction of 7 T and higher magnetic fields for human investigation at about the turn of the century. Work conducted on these platforms has demonstrated the existence of significant advantages in SNR and biological information content at these ultrahigh fields, as well as the presence of numerous challenges. Primary difference from lower fields is the deviation from the near field regime; at the frequencies corresponding to hydrogen resonance conditions at ultrahigh fields, the RF is characterized by attenuated traveling waves in the human body, which leads to image nonuniformities for a given sample-coil configuration because of interferences. These nonuniformities were considered detrimental to the progress of imaging at high field strengths. However, they are advantageous for parallel imaging for signal reception and parallel transmission, two critical technologies that account, to a large extend, for the success of ultrahigh fields. With these technologies, and improvements in instrumentation and imaging methods, ultra-high fields have provided unprecedented gains in imaging of brain function and anatomy, and started to make inroads into investigation of the human torso and extremities. As extensive as they are, these gains still constitute a prelude to what is to come given the increasingly larger effort committed to ultrahigh field research and development of ever better instrumentation and techniques. PMID:24686229
[Introduction of rapid syphilis and HIV testing in prenatal care in Colombia: qualitative analysis].
Ochoa-Manjarrés, María Teresa; Gaitán-Duarte, Hernando Guillermo; Caicedo, Sidia; Gómez, Berta; Pérez, Freddy
2016-12-01
Interpret perceptions of Colombian health professionals concerning factors that obstruct and facilitate the introduction of rapid syphilis and HIV testing in prenatal care services. A qualitative study based on semi-structured interviews was carried out. A convenience sample was selected with 37 participants, who included health professionals involved in prenatal care services, programs for pregnant women, clinical laboratories, and directors of health care units or centers, as well as representatives from regional departments and the Ministry of Health. Colombia does not do widespread screening with rapid syphilis and HIV tests in prenatal care. The professionals interviewed stated they did not have prior experience in the use of rapid tests-except for laboratory staff-or in the course of action in response to a positive result. The insurance system hinders access to timely diagnosis and treatment. Health authorities perceive a need to review existing standards, strengthen the first level of care, and promote comprehensive prenatal care starting with contracts between insurers and health service institutional providers. Participants recommended staff training and integration between health-policymaking and academic entities for updating training programs. The market approach and the characteristics of the Colombian health system constitute the main barriers to implementation of rapid testing as a strategy for elimination of mother-to-child transmission of syphilis and HIV. Measures identified include making changes in contracts between insurers and health service institutional providers, adapting the timing and duration of prenatal care procedures, and training physicians and nurses involved in prenatal care.
Sadoh, Ayebo Evawere; Nwaneri, Damian Uchechukwu; Ogboghodo, Bamidele Charity; Sadoh, Wilson Ehidiamen
2016-05-23
The introduction of a new vaccine into an immunization programme may affect the immunization system negatively or positively. The aim of this study is to determine the effect of the introduction of the pentavalent vaccine as replacement for DTP and Hepatitis B vaccines on timeliness, completion of the schedule and dropout rates among children attending a health facility. This was a retrospective cohort study which involved extracting immunization records of children attending the Institute of Child Health Child Welfare Clinic between June 2011 and May 2013. Pentavalent vaccine was introduced as a replacement for DTP and Hepatitis B vaccines in June 2012. The uptake, timeliness and dropout rates of different vaccines in the immunization schedule were determined for children who commenced immunization in the pre, peri and post introduction phases. A total of 1110 children were studied - 190, 410 and 510 who commenced vaccination in the pre, peri and post introduction phases of the pentavalent vaccine respectively. Uptake was significantly higher for all vaccines in the post introduction phase compared to pre and peri introduction phases (p<0.001). Completion of the immunization schedule by 60.2% of the children who commenced vaccination in the post introduction phase was higher than the 31.6% and 41.7% for the pre and peri introduction phases respectively (p<0.001). Significantly more visits were required to complete the schedule in the peri introduction phase compared to the pre and post introduction phases p<0.001. Delay in receipt of the three doses of DTP/PENTA was significantly longer in the peri introduction phase compared to pre and post introduction phases. The introduction of pentavalent vaccine significantly improved uptake of vaccines and completion of the schedule but resulted in prolonged delay in receipt of vaccines during the introduction period. Copyright © 2016 Elsevier Ltd. All rights reserved.
How to write an introduction section of a scientific article?
Armağan, Abdullah
2013-09-01
An article primarily includes the following sections: introduction, materials and methods, results, discussion, and conclusion. Before writing the introduction, the main steps, the heading and the familiarity level of the readers should be considered. Writing should begin when the experimental system and the equipment are available. The introduction section comprises the first portion of the manuscript, and it should be written using the simple present tense. Additionally, abbreviations and explanations are included in this section. The main goal of the introduction is to convey basic information to the readers without obligating them to investigate previous publications and to provide clues as to the results of the present study. To do this, the subject of the article should be thoroughly reviewed, and the aim of the study should be clearly stated immediately after discussing the basic references. In this review, we aim to convey the principles of writing the introduction section of a manuscript to residents and young investigators who have just begun to write a manuscript.
Steinhaus’ Geometric Location Problem for Random Samples in the Plane.
1982-05-11
NAL 411R A1, ’I 7 - I STEINHAUS ’ GEOMETRIC LOCATION PROBLEM FOR RANDOM SAMPLES IN THE PLANE By Dorit Hochbaum and J. Michael Steele TECHNICAL REPORT...DEPARTMENT OF STATISTICS -Dltrib’ytion/ STANFORD UNIVERSITY A-I.abilty Codes STANFORD, CALIFORNIA Dist Spciat ecial Steinhaus ’ Geometric Location Problem for...Random Samples in the Plane By Dorit Hochbaum and J. Michael Steele I. Introduction. The work of H. Steinhaus U wf94 as apparently the first explicit
Apparatus and process for collection of gas and vapor samples
Jackson, Dennis G [Augusta, GA; Peterson, Kurt D [Aiken, SC; Riha, Brian D [Augusta, GA
2008-04-01
A gas sampling apparatus and process is provided in which a standard crimping tool is modified by an attached collar. The collar permits operation of the crimping tool while also facilitating the introduction of a supply of gas to be introduced into a storage vial. The introduced gas supply is used to purge ambient air from a collection chamber and an interior of the sample vial. Upon completion of the purging operation, the vial is sealed using the crimping tool.
A Brief Historical Introduction to Fractals and Fractal Geometry
ERIC Educational Resources Information Center
Debnath, Lokenath
2006-01-01
This paper deals with a brief historical introduction to fractals, fractal dimension and fractal geometry. Many fractals including the Cantor fractal, the Koch fractal, the Minkowski fractal, the Mandelbrot and Given fractal are described to illustrate self-similar geometrical figures. This is followed by the discovery of dynamical systems and…
1988-07-08
Marcus and C. Baczynski), Computer Science Press, Rockville, Maryland, 1986. 3. An Introduction to Pascal and Precalculus , Computer Science Press...Science Press, Rockville, Maryland, 1986. 35. An Introduction to Pascal and Precalculus , Computer Science Press, Rockville, Maryland, 1986. 36
An Introduction to Computational Physics
NASA Astrophysics Data System (ADS)
Pang, Tao
2010-07-01
Preface to first edition; Preface; Acknowledgements; 1. Introduction; 2. Approximation of a function; 3. Numerical calculus; 4. Ordinary differential equations; 5. Numerical methods for matrices; 6. Spectral analysis; 7. Partial differential equations; 8. Molecular dynamics simulations; 9. Modeling continuous systems; 10. Monte Carlo simulations; 11. Genetic algorithm and programming; 12. Numerical renormalization; References; Index.
The Australian Perspective: Access, Equity, Quality, and Accountability in Higher Education
ERIC Educational Resources Information Center
Sharma, Rajendra
2008-01-01
The Australian higher education system has experienced significant changes since the mid-1980s. Notable are introduction of an income-contingent loan (the Higher Education Contribution Scheme) for "government" funded places; changing from aid to trade with respect to international students, including introduction of full fees for such…
Opportunities and challenges for harvest weed seed control in global cropping systems
USDA-ARS?s Scientific Manuscript database
The introduction of mechanical harvesting and the retention of high proportions of weed seed at crop harvest created the opportunity to target weed seeds many decades ago; however, this approach to weed control has been largely neglected until more recently. The introduction and adoption of harvest ...
Capabilities Roadmap Briefings to the National Research Council
NASA Technical Reports Server (NTRS)
2005-01-01
High energy power and propulsion capability roadmap - general background and introduction. Advanced telescopes and observatories and scientific instruments and sensors capability roadmaps - general background and introduction. Space communications capability roadmap interim review. Robotic access to planetary surface capability roadmap. Human health and support systems capability roadmap progress review.
Tourism through Travel Club: A Database Project
ERIC Educational Resources Information Center
Pratt, Renée M. E.; Smatt, Cindi T.; Wynn, Donald E.
2017-01-01
This applied database exercise utilizes a scenario-based case study to teach the basics of Microsoft Access and database management in introduction to information systems and introduction to database course. The case includes background information on a start-up business (i.e., Carol's Travel Club), description of functional business requirements,…
Map for Decision Making in Operating Distance Learning System--Research Results.
ERIC Educational Resources Information Center
Offir, Baruch
2000-01-01
Examines decision-making aspects of the introduction of distance learning into university instruction and learning based on experiences in Israel. Discusses the introduction of information technology into the classroom; examines teacher/student interactions; and suggests a model for introducing distance learning that focuses on the role of the…
NASA Technical Reports Server (NTRS)
Jemian, Wartan A.
1986-01-01
Weld radiograph enigmas are features observed on X-ray radiographs of welds. Some of these features resemble indications of weld defects, although their origin is different. Since they are not understood, they are a source of concern. There is a need to identify their causes and especially to measure their effect on weld mechanical properties. A method is proposed whereby the enigmas can be evaluated and rated, in relation to the full spectrum of weld radiograph indications. Thie method involves a signature and a magnitude that can be used as a quantitive parameter. The signature is generated as the diference between the microdensitometer trace across the radiograph and the computed film intensity derived from a thickness scan along the corresponding region of the sample. The magnitude is the measured difference in intensity between the peak and base line values of the signature. The procedure is demonstated by comparing traces across radiographs of a weld sample before and after the introduction of a hole and by a system based on a MacIntosh mouse used for surface profiling.
Cerai Ferreira, Conny; Malta Costa, Letícia; Sanches Barbeira, Paulo Jorge
2015-06-01
A measurement procedure for direct and simultaneous quantification of Na, K and Ca in biodiesel by flame atomic emission spectroscopy (FAES) was developed. A lab-made device was constructed by coupling a nebulizer/combustion system from a commercial photometer to a continuous emission detector in a spectral range of 255 to 862 nm. Instrumental optimizations were carried out evaluating the most important variables, such as gas flow rates and sample introduction temperature, indicating that a temperature of 50°C enhances the analytical signals and assures good precision. The direct analysis method was properly validated and presented limits of quantification of 0.09, 0.07 and 0.43 μg kg(-1) for Na, K and Ca, respectively. Accuracy of the proposed procedure was checked by comparing the results with those obtained by the standard procedure described in ABNT NBR 15556 and the standard addition method. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Yurenya, Anton Y.; Polikarpov, Mikhail A.; Chukalova, Aynur A.; Moskaleva, Elizaveta Y.; Taldenkov, Alexander N.; Panchenko, Vladislav Y.
2017-04-01
Earlier we proposed a new radiotherapy enhancement method that entails the administration of 57Fe iron-oxide nanoparticles into the cells [5]. Within this work we were prompt to investigate the capability of iron oxide nanoparticles with monolayer coating to penetrate into live cells. Magnetite particle samples were synthesized and stabilized with HCl or citric acid. The cells were incubated in the presence of nanoparticles for 1 h, washed and dried. To distinguish inside-cell particles from outside ones a set of experiments with low temperature incubation was carried out. Several cell samples were prepared in the presence of an external magnetic field in order to study the possibility of the nanoparticle uptake enhancement. To evaluate the amount of particles in each cell sample we used a SQUID-magnetometer. The nanoparticle suspension with HCl stabilization turned to be inadequate for intracellular introduction. Approximately 2·105 particles with citric acid covering conjugated with each cell after incubation at normal conditions. An application of an external magnetic field increased this amount up to 107 particles/cell. Most probably much of these particles penetrated into cells.
Park, Chang-Gyu; Min, Sujeong; Lee, Gwan-Seok; Kim, Sora; Lee, Yerim; Lee, Seunghwan; Hong, Ki-Jeong; Wilson, Stephen W; Akimoto, Shin-Ichi; Lee, Wonhoon
2016-08-01
Metcalfa pruinosa (Say, 1830) (Hemiptera: Flatidae) has caused substantial agricultural damage since its recent introduction to the Republic of Korea; however, the source of this introduction is still unclear. To examine the genetic divergence and phylogenetic relationships among several populations of M. pruinosa from Korea and foreign countries, 251 COI sequences from 251 samples collected from Korea, France, Italy, Spain, Slovenia, and the United States were newly analyzed, together with seven published COI sequences from Canada. In total, 19 haplotypes were detected from the 258 COI sequences, and three haplotypes, H1, H3, and H9, were detected from samples in Korea. The MJ network and Bayesian inference revealed that the three haplotypes of Korea were closely connected with samples of Italy, Spain, Slovenia, France, and the United States. Our study revealed the possibility of multiple invasions of M. pruinosa from Europe and/or North America into Korea. © The Authors 2016. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Climate Literacy: STEM and Climate Change Education and Remote Sensing Applications
NASA Astrophysics Data System (ADS)
Reddy, S. R.
2015-12-01
NASA Innovations in Climate Education (NICE) is a competitive project to promote climate and Earth system science literacy and seeks to increase the access of underrepresented minority groups to science careers and educational opportunities. A three year funding was received from NASA to partnership with JSU and MSU under cooperative agreement "Strengthening Global Climate Change education through Remote Sensing Application in Coastal Environment using NASA Satellite Data and Models". The goal is to increase the number of highschool and undergraduate students at Jackson State University, a Historically Black University, who are prepared to pursue higher academic degrees and careers in STEM fields. A five Saturday course/workshop was held during March/April 2015 at JSU, focusing on historical and technical concepts of math, enginneering, technology and atmosphere and climate change and remote sensing technology and applications to weather and climate. Nine students from meteorology, biology, industrial technology and computer science/engineering of JSU and 19 high scool students from Jackson Public Schools participated in the course/workshop. The lecture topics include: introduction to remote sensing and GIS, introduction to atmospheric science, math and engineering, climate, introduction to NASA innovations in climate education, introduction to remote sensing technology for bio-geosphere, introduction to earth system science, principles of paleoclimatology and global change, daily weather briefing, satellite image interpretation and so on. In addition to lectures, lab sessions were held for hand-on experiences for remote sensing applications to atmosphere, biosphere, earth system science and climate change using ERDAS/ENVI GIS software and satellite tools. Field trip to Barnett reservoir and National weather Service (NWS) was part of the workshop. Basics of Earth System Science is a non-mathematical introductory course designed for high school seniors, high school teachers and undergraduate students who may or may not have adequate exposure to fundamental concepts of the key components of the modern earth system and their interactions. This is an online course that will be delivered using Blackboard platform available at Jackson State University.
Munyisia, Esther N; Yu, Ping; Hailey, David
2011-02-01
To date few studies have compared nursing home caregivers' perceptions about the quality of information and benefits of nursing documentation in paper and electronic formats. With the increased interest in the use of information technology in nursing homes, it is important to obtain information on the benefits of newer approaches to nursing documentation so as to inform investment, organisational and care service decisions in the aged care sector. This study aims to investigate caregivers' perceptions about the quality of information and benefits of nursing documentation before and after the introduction of an electronic documentation system in a nursing home. A self-administered questionnaire survey was conducted three months before, and then six, 18 and 31 months after the introduction of an electronic documentation system. Further evidence was obtained through informal discussions with caregivers. Scores for questionnaire responses showed that the benefits of the electronic documentation system were perceived by the caregivers as provision of more accurate, legible and complete information, and reduction of repetition in data entry, with consequential managerial benefits. However, caregivers' perceptions of relevance and reliability of information, and of their communication and decision-making abilities were perceived to be similar either using an electronic or a paper-based documentation system. Improvement in some perceptions about the quality of information and benefits of nursing documentation was evident in the measurement conducted six months after the introduction of the electronic system, but were not maintained 18 or 31 months later. The electronic documentation system was perceived to perform better than the paper-based system in some aspects, with subsequent benefits to management of aged care services. In other areas, perceptions of additional benefits from the electronic documentation system were not maintained. In a number of attributes, there were similar perceptions on the two types of systems. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Kristin Bunte; Steven R. Abt
2001-01-01
This document provides guidance for sampling surface and subsurface sediment from wadable gravel-and cobble-bed streams. After a short introduction to streams types and classifications in gravel-bed rivers, the document explains the field and laboratory measurement of particle sizes and the statistical analysis of particle-size distributions. Analysis of particle...
USDA-ARS?s Scientific Manuscript database
The QuEChERS (quick, easy, cheap, effective, rugged, and safe) sample preparation method was modified to accommodate various cereal grain matrices (corn, oat, rice and wheat) and provide good analytical results (recoveries in the range of 70-120% and RSDs <20%) for the majority of the target pestici...
CT-guided thermocouple placement for hyperthermia treatment.
Banerian, K G; Roberts, J L; Borrego, J C; Martinez, A
1990-05-01
There is a well-documented synergistic cytotoxic effect when heat is combined with ionizing radiation. An integral component of hyperthermia treatments is the placement of thermocouple probes used for thermal dosimetry. With the surge in interest in the clinical use of hyperthermia, our department is performing an increasing number of thermocouple placements under computed tomographic (CT) guidance. We describe our technique for CT-guided thermocouple placement with two different systems: a trocar introduction system and a peel-away needle introduction system. We discuss the rationale for thermocouple placement, our early experience with this technique, and some potential complications.
Utilization of sugarcane industrial residues as animal food and probiotic medium.
Apás, Ana Lidia; Arena, Mario Eduardo; Draksler, Diana; González, Silvia Nelina
2008-10-01
Sugar production from sugarcane generates residual products, currently, many of which are waste products. At the same time, introduction of probiotic bacteria to food animals needs an economical production medium. Fermentation of sugarcane blunting, an industrial residue, inoculated with ruminant probiotic bacteria was investigated. Fermentation was carried out using native flora (NF) alone, NF plus a goat probiotic lactic acid bacterium (LAB), and NF plus goat probiotic co-inoculated with two LAB isolated from sugarcane. Survival of microorganisms and metabolite produce were monitored. In the inoculated samples, pH was lower, dry matter was >30%, and Enterobacteriaceae and fungus decreased when compared to natural fermentation. The LAB inoculated grew and multiplied during fermentation. All beneficial changes were more quickly in the co-inoculated samples. The results presented indicate that sugarcane blunting can be used as a medium for introduction of ruminant probiotic bacteria. Fermentation of blunting can prolong shelf life and increase microbiological safety.
Velázquez-Velázquez, Ernesto; González-Solís, David; Salgado-Maldonado, Guillermo
2011-09-01
The Asian fish tapeworm, Bothriocephalus acheilognathi, has been considered one of the most dangerous parasites for cultured carp and a risk for native freshwater fish populations worldwide. This cestode is highly pathogenic for fishes especially fry. In this paper we record B. acheilognathi parasitizing the endangered and endemic freshwater fish Profundulus hildebrandi from the endorheic basin of San Crist6bal de las Casas, Chiapas, Mexico. B. acheilognathi was recorded from 10 of the 11 sampled localities, with high values of prevalence (> 60%) and mean abundance (> 4.50). The infection was persistent all through the year; gravid cestodes were recorded in all samples. It is assumed that B. acheilognathi entered to this area through the introduction of common carp Cyprinus carpio, for aquacultural purposes. The data presented in this paper document the successful introduction, colonization and establishment of this alien species into the endangered P. hildebrandi.
de Melo, P B; Nunes, A M; Omena, L; do Nascimento, S M S; da Silva, M G A; Meneghetti, M R; de Oliveira, I N
2015-10-01
The present work is devoted to the study of the thermo-optical and nonlinear optical properties of smectic samples containing gold nanoparticles with different shapes. By using the time-resolved Z-scan technique, we determine the effects of nanoparticle addition on the critical behavior of the thermal diffusivity and thermo-optical coefficient at the vicinity of the smectic-A-nematic phase transition. Our results reveal that introduction of gold nanoparticles affects the temperature dependence of thermo-optical parameters, due to the local distortions in the orientational order and heat generation provided by guest particles during the laser exposure. Further, we show that a nonlinear optical response may take place at temperatures where the smectic order is well established. We provide a detailed discussion of the effects associated with the introduction gold nanoparticles on the mechanisms behind the thermal transport and optical nonlinearity in liquid-crystal samples.
Free energy from molecular dynamics with multiple constraints
NASA Astrophysics Data System (ADS)
den Otter, W. K.; Briels, W. J.
In molecular dynamics simulations of reacting systems, the key step to determining the equilibrium constant and the reaction rate is the calculation of the free energy as a function of the reaction coordinate. Intuitively the derivative of the free energy is equal to the average force needed to constrain the reaction coordinate to a constant value, but the metric tensor effect of the constraint on the sampled phase space distribution complicates this relation. The appropriately corrected expression for the potential of mean constraint force method (PMCF) for systems in which only the reaction coordinate is constrained was published recently. Here we will consider the general case of a system with multiple constraints. This situation arises when both the reaction coordinate and the 'hard' coordinates are constrained, and also in systems with several reaction coordinates. The obvious advantage of this method over the established thermodynamic integration and free energy perturbation methods is that it avoids the cumbersome introduction of a full set of generalized coordinates complementing the constrained coordinates. Simulations of n -butane and n -pentane in vacuum illustrate the method.
NASA Astrophysics Data System (ADS)
Anzai, Mayuka; Kawakami, Hiroshi; Saito, Miwa; Yamamura, Hiroshi
2011-05-01
Thermoelectric properties of Sr-doped LaCoO3 system which includes both La1-xSrxCoO3 and La0.95-xSrxsquare0.05CoO3 containing the A-site vacancy were prepared by solid state reaction. The crystal phases of the samples were investigated by X-ray diffraction method. The electrical conductivity, Seebeck coefficient, and thermal conductivity were investigated, focusing the effect of A-site vacancy. Doping of Sr to LaCoO3 improved the electrical conductivity but decreased the seebeck coefficient and increased the thermal conductivity. A-site vacancy of La0.95-xSrxsquare0.05CoO3 system, in comparison with La1-xSrxCoO3 system, increased electrical conductivity, and decreased lattice thermal conductivity. As a result, it was found that the thermoelectric properties of La0.95-xSrxsquare0.05CoO3 containing the A-site vacancy showed the higher values than those of La1-xSrxCoO3. The introduction of A-site vacancy was effective on the improvement of thermoelectric property.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Majewski, P.; Aldinger, F.; Elschner, S.
1994-12-31
Considering the phase equilibrium diagram of the system Bi{sub 2}O{sub 3}-SrO-CaO-CuO, single phase {open_quotes}Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8}{close_quotes} ceramics have been transformed by a simple annealing procedure into multi phase samples. The transformation results in the formation of second phases and in an increase of the intra grain critical current density at 1 T of five times. This increase is believed to express improved pinning properties of the superconducting crystals. The prepared pinning centres are believed to be e.g. coherent precipitates (Guinier-Preston-zones) within the superconducting crystals.
Correction of elevation offsets in multiple co-located lidar datasets
Thompson, David M.; Dalyander, P. Soupy; Long, Joseph W.; Plant, Nathaniel G.
2017-04-07
IntroductionTopographic elevation data collected with airborne light detection and ranging (lidar) can be used to analyze short- and long-term changes to beach and dune systems. Analysis of multiple lidar datasets at Dauphin Island, Alabama, revealed systematic, island-wide elevation differences on the order of 10s of centimeters (cm) that were not attributable to real-world change and, therefore, were likely to represent systematic sampling offsets. These offsets vary between the datasets, but appear spatially consistent within a given survey. This report describes a method that was developed to identify and correct offsets between lidar datasets collected over the same site at different times so that true elevation changes over time, associated with sediment accumulation or erosion, can be analyzed.
AERODYNAMIC CHARACTERISTICS OF TWO ROTARY WING UAV DESIGNS
NASA Technical Reports Server (NTRS)
Jones, Henry E.; Wong, Oliver D.; Noonan, Kevin W.; Reis, Deane G.; Malovrh, Brendon D.
2006-01-01
This paper presents the results of an experimental investigation of two rotary-wing UAV designs. The primary goal of the investigation was to provide a set of interactional aerodynamic data for an emerging class of rotorcraft. The present paper provides an overview of the test and an introduction to the test articles, and instrumentation. Sample data in the form of a parametric study of fixed system lift and drag coefficient response to changes in configuration and flight condition for both rotor off and on conditions are presented. The presence of the rotor is seen to greatly affect both the character and magnitude of the response. The affect of scaled stores on body drag is observed to be dependent on body shape.
Aerodynamic Characteristics of Two Rotary Wing UAV Designs
NASA Technical Reports Server (NTRS)
Jones, Henry E.; Wong, Oliver D.; Noonan, Kevin W.; Reis, Deane G.; Malovrh, Brendon D.
2006-01-01
This paper presents the results of an experimental investigation of two rotary-wing UAV designs. The primary goal of the investigation was to provide a set of interactional aerodynamic data for an emerging class of rotorcraft. The present paper provides an overview of the test and an introduction to the test articles, and instrumentation. Sample data in the form of a parametric study of fixed system lift and drag coefficient response to changes in configuration and flight condition for both rotor off and on conditions are presented. The presence of the rotor is seen to greatly affect both the character and magnitude of the response. The affect of scaled stores on body drag is observed to be dependent on body shape.
NASA Astrophysics Data System (ADS)
Chorover, J.; Kong, S.; Root, R. A.; Thomas, A.
2015-12-01
Bioaccessibility of contaminant metals in geomedia is often measured on the basis of kinetic release to solution during in vitro reaction with biofluid simulants. We postulate that development of a predictive-mechanistic understanding of bioaccessibility requires knowledge of metal(loid) molecular speciation upon sample introduction, as well as its change over the course of the in vitro reaction. Our results - including data from batch, column, mesocosm and field studies pertaining to arsenic, lead, and zinc contaminated materials - indicate the strong influence of organic matter and associated biological activity on metal(loid) speciation in mine tailings and related model systems. Furthermore, presence/absence of organic matter during bioassays affects the kinetics of metal(loid) release into biofluid simulants through multiple mechanisms.
Juhnke, Christin; Mühlbacher, Axel C.
2013-01-01
Introduction Patient-centred healthcare is becoming a more significant success factor in the design of integrated healthcare systems. The objective of this study is to structure a patient-relevant hierarchy of needs and expectations for the design of organised healthcare delivery systems. Methods A questionnaire with 84 items was conducted with N = 254 healthcare experts and N = 670 patients. Factor analyses were performed using SPSS©18. The number of factors retained was controlled by Kaiser's criterion, validation of screeplots and interpretability of the items. Cronbach's α was used to assess the internal consistency of the subscales. Results Exploratory factor analysis led to 24 factors in the expert sample and 20 in the patient sample. After analysing the screeplots, confirmatory factor analyses were computed for 7-factor solutions accounting for 42.963% of the total variance and Kaiser–Meyer–Olkin of 0.914 for the patients (experts: 38.427%, Kaiser–Meyer–Olkin = 0.797). Cronbach's α ranged between 0.899 and 0.756. Based on the analysis, coordinated care could be differentiated into seven dimensions: access, data and information, service and infrastructure, professional care, interpersonal care, individualised care, continuity and coordination. Conclusion and Discussion The study provides insight into patient and experts expectations towards the organisation of integrated healthcare delivery systems. If providers and payers can take into account patient needs and expectations while implementing innovative healthcare delivery systems, greater acceptance and satisfaction will be achieved. In the best case, this will lead to better adherence resulting in better clinical outcomes. PMID:24363639
Method to make accurate concentration and isotopic measurements for small gas samples
NASA Astrophysics Data System (ADS)
Palmer, M. R.; Wahl, E.; Cunningham, K. L.
2013-12-01
Carbon isotopic ratio measurements of CO2 and CH4 provide valuable insight into carbon cycle processes. However, many of these studies, like soil gas, soil flux, and water head space experiments, provide very small gas sample volumes, too small for direct measurement by current constant-flow Cavity Ring-Down (CRDS) isotopic analyzers. Previously, we addressed this issue by developing a sample introduction module which enabled the isotopic ratio measurement of 40ml samples or smaller. However, the system, called the Small Sample Isotope Module (SSIM), does dilute the sample during the delivery with inert carrier gas which causes a ~5% reduction in concentration. The isotopic ratio measurements are not affected by this small dilution, but researchers are naturally interested accurate concentration measurements. We present the accuracy and precision of a new method of using this delivery module which we call 'double injection.' Two portions of the 40ml of the sample (20ml each) are introduced to the analyzer, the first injection of which flushes out the diluting gas and the second injection is measured. The accuracy of this new method is demonstrated by comparing the concentration and isotopic ratio measurements for a gas sampled directly and that same gas measured through the SSIM. The data show that the CO2 concentration measurements were the same within instrument precision. The isotopic ratio precision (1σ) of repeated measurements was 0.16 permil for CO2 and 1.15 permil for CH4 at ambient concentrations. This new method provides a significant enhancement in the information provided by small samples.
2012-07-01
SCI-228) Executive Summary This AGARDograph presents an introduction to fiber optic systems and is intended to provide a basic understanding of...22 / SCI-228) Synthèse Cette AGARDograph présente une introduction aux systèmes à fibres optiques et a pour objet d’expliquer l’utilisation de ces...l’instrumentation des essais en vol dans l’ensemble des pays membres de l’OTAN, entraînant la disparition progressive des jauges extensométriques et des
Caudron, Jean Michel; Schiavetti, Benedetta; Pouget, Corinne; Tsoumanis, Achilleas; Meessen, Bruno; Ravinetto, Raffaella
2018-01-01
Introduction The rapid globalisation of the pharmaceutical production and distribution has not been supported by harmonisation of regulatory systems worldwide. Thus, the supply systems in low-income and middle-income countries (LMICs) remain exposed to the risk of poor-quality medicines. To contribute to estimating this risk in the private sector in LMICs, we assessed the quality assurance system of a convenient sample of local private pharmaceutical distributors. Methods This descriptive study uses secondary data derived from the audits conducted by the QUAMED group at 60 local private pharmaceutical distributors in 13 LMICs. We assessed the distributors’ compliance with good distribution practices (GDP), general quality requirements (GQR) and cold chain management (CCM), based on an evaluation tool inspired by the WHO guidelines ’Model Quality Assurance System (MQAS) for procurement agencies'. Descriptive statistics describe the compliance for the whole sample, for distributors in sub-Saharan Africa (SSA) versus those in non-SSA, and for those in low-income countries (LICs) versus middle-income countries (MICs). Results Local private pharmaceutical distributors in our sample were non-compliant, very low-compliant or low-compliant for GQR (70%), GDP (60%) and CCM (41%). Only 7/60 showed good to full compliance for at least two criteria. Observed compliance varies by geographical region and by income group: maximum values are higher in non-SSA versus SSA and in MICs versus LICs, while minimum values are the same across different groups. Conclusion The poor compliance with WHO quality standards observed in our sample indicates a concrete risk that patients in LMICs are exposed to poor-quality or degraded medicines. Significant investments are needed to strengthen the regulatory supervision, including on private pharmaceutical distributors. An adapted standardised evaluation tool inspired by the WHO MQAS would be helpful for self-evaluation, audit and inspection purposes. PMID:29915671
Ferreira Júnior, Washington Soares; Ramos, Marcelo Alves; da Silva, Taline Cristina; Ladio, Ana Haydée; Albuquerque, Ulysses Paulino
2017-01-01
Efforts have been made to understand the processes that lead to the introduction of exotic species into local pharmacopoeias. Among those efforts, the diversification hypothesis predicts that exotic plants are introduced in local medical systems to amplify the repertoire of knowledge related to the treatment of diseases, filling blanks that were not occupied by native species. Based on such hypothesis, this study aimed to contribute to this discussion using the context of local Brazilian populations. We performed a systematic review of Brazilian studies up to 2011 involving medicinal plants, excluding those studies that presented a high risk of bias (because of sampling or plant identification problems). An analysis of similarities (ANOSIM) was conducted in different scales to test for differences in the repertoire of therapeutic indications treated using native and exotic species. We have found that although there is some overlap between native and exotic plants regarding their therapeutic indications and the body systems (BSs) that they treat, there are clear gaps present, that is, there are therapeutic indications and BSs treated that are exclusive to exotic species. This scenario enables the postulation of two alternative unfoldings of the diversification hypothesis, namely, (1) exotic species are initially introduced to fill gaps and undergo subsequent expansion of their use for medical purposes already addressed using native species and (2) exotic species are initially introduced to address problems already addressed using native species to diversify the repertoire of medicinal plants and to increase the resilience of medical systems. The reasons why exotic species may have a competitive advantage over the native ones, the implications of the introduction of exotic species for the resilience of medical systems, and the contexts in which autochthonous plants can gain strength to remain in pharmacopoeias are also discussed. PMID:28953960
Kim, Sang Hyun
2013-12-01
The purpose of this study was to examine the concordance between a checklist's categories of professor recommendation letters and characteristics of the self-introduction letter. Checklists of professor recommendation letters were analyzed and classified into cognitive, social, and affective domains. Simple correlation was performed to determine whether the characteristics of the checklists were concordant with those of the self-introduction letter. The difference in ratings of the checklists by pass or fail grades was analyzed by independent sample t-test. Logistic regression analysis was performed to determine whether a pass or fail grade was influenced by ratings on the checklists. The Cronbach alpha value of the checklists was 0.854. Initiative, as an affective domain, in the professor's recommendation letter was highly ranked among the six checklist categories. Self-directed learning in the self-introduction letter was influenced by a pass or fail grade by logistic regression analysis (p<0.05). Successful applicants received higher ratings than those who failed in every checklist category, particularly in problem-solving ability, communication skills, initiative, and morality (p<0.05). There was a strong correlation between cognitive and affective characteristics in the professor recommendation letters and the sum of all characteristics in the self-introduction letter.
Enko, Dietmar; Mangge, Harald; Münch, Andreas; Niedrist, Tobias; Mahla, Elisabeth; Metzler, Helfried; Prüller, Florian
2017-01-01
Introduction The aim of this study was to assess pneumatic tube system (PTS) alteration on platelet function by the light transmission aggregometry (LTA) and whole blood aggregometry (WBA) method, and on the results of platelet count, prothrombin time (PT), activated partial thromboplastin time (APTT), and fibrinogen. Materials and methods Venous blood was collected into six 4.5 mL VACUETTE® 9NC coagulation sodium citrate 3.8% tubes (Greiner Bio-One International GmbH, Kremsmünster, Austria) from 49 intensive care unit (ICU) patients on dual anti-platelet therapy and immediately hand carried to the central laboratory. Blood samples were divided into 2 Groups: Group 1 samples (N = 49) underwent PTS (4 m/s) transport from the central laboratory to the distant laboratory and back to the central laboratory, whereas Group 2 samples (N = 49) were excluded from PTS forces. In both groups, LTA and WBA stimulated with collagen, adenosine-5’-diphosphate (ADP), arachidonic acid (AA) and thrombin-receptor-activated-peptide 6 (TRAP-6) as well as platelet count, PT, APTT, and fibrinogen were performed. Results No statistically significant differences were observed between blood samples with (Group 1) and without (Group 2) PTS transport (P values from 0.064 – 0.968). The AA-induced LTA (bias: 68.57%) exceeded the bias acceptance limit of ≤ 25%. Conclusions Blood sample transportation with computer controlled PTS in our hospital had no statistically significant effects on platelet aggregation determined in patients with anti-platelet therapy. Although AA induced LTA showed a significant bias, the diagnostic accuracy was not influenced. PMID:28392742
Giardi, Fabio; Traversi, Rita; Becagli, Silvia; Severi, Mirko; Caiazzo, Laura; Ancillotti, Claudia; Udisti, Roberto
2018-02-01
An inductively coupled plasma sector field mass spectrometer (ICP-SFMS) was used to develop an analytical method for the fast determination of Na, Al, Sc, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Y, Mo, Cd, Ba, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, and Pb in Arctic size-segregated aerosol samples (PM 10 ), after microwave acidic digestion. The ICP-SFMS was coupled with a microflow nebulizer and a desolvation system for the sample introduction, which reduced the isobaric interferences due to oxides and the required volume of sample solutions, compared to the usual nebulization chamber methods. With its very low limit of detection, and taking into account the level of blanks, this method allowed the quantification of many metals in very low concentration. Particular attention was given to Rare Earth Elements (REEs - La to Lu). The efficiency in the extraction of REEs was proved to be acceptable, with recoveries over 83% obtained with a Certified Reference Material (AMiS 0356). The analytical method was then applied to particulate matter samples, collected at ground level in Ny Ålesund (Svalbard Islands, Norway), during spring and summer, from 2010 to 2015, with daily resolution and using a low-volume device. Thus, for the first time, a large atmospheric concentrations dataset of metals in Arctic particulate matter at high temporal resolution is presented. On the basis of differences in LREE/HREE ratio and Ce and Eu anomalies in spring and summer samples, basic information to distinguish local and long-range transported dust were achieved. Copyright © 2017 Elsevier B.V. All rights reserved.
Müller, Marco; Wasmer, Katharina; Vetter, Walter
2018-06-29
Countercurrent chromatography (CCC) is an all liquid based separation technique typically used for the isolation and purification of natural compounds. The simplicity of the method makes it easy to scale up CCC separations from analytical to preparative and even industrial scale. However, scale-up of CCC separations requires two different instruments with varying coil dimensions. Here we developed two variants of the CCC multiple injection mode as an alternative to increase the throughput and enhance productivity of a CCC separation when using only one instrument. The concept is based on the parallel injection of samples at different points in the CCC column system and the simultaneous separation using one pump only. The wiring of the CCC setup was modified by the insertion of a 6-port selection valve, multiple T-pieces and sample loops. Furthermore, the introduction of storage sample loops enabled the CCC system to be used with repeated injection cycles. Setup and advantages of both multiple injection modes were shown by the isolation of the furan fatty acid 11-(3,4-dimethyl-5-pentylfuran-2-yl)-undecanoic acid (11D5-EE) from an ethyl ester oil rich in 4,7,10,13,16,19-docosahexaenoic acid (DHA-EE). 11D5-EE was enriched in one step from 1.9% to 99% purity. The solvent consumption per isolated amount of analyte could be reduced by ∼40% compared to increased throughput CCC and by ∼5% in the repeated multiple injection mode which also facilitated the isolation of the major compound (DHA-EE) in the sample. Copyright © 2018 Elsevier B.V. All rights reserved.
A voyage to Terra Australis: human-mediated dispersal of cats.
Koch, K; Algar, D; Searle, J B; Pfenninger, M; Schwenk, K
2015-12-04
Cats have been transported as human commensals worldwide giving rise to many feral populations. In Australia, feral cats have caused decline and extinction of native mammals, but their time of introduction and origin is unclear. Here, we investigate hypotheses of cat arrival pre- or post-European settlement, and the potential for admixture between cats of different invasion events. We analyse the genetic structure and diversity of feral cats from six locations on mainland Australia, seven Australian islands and samples from Southeast Asia and Europe using microsatellite and mitochondrial DNA data. Our results based on phylogeographic model selection are consistent with a European origin of cats in Australia. We find genetic distinctiveness of Australian mainland samples compared with Dirk Hartog Island, Flinders Island, Tasman Island and Cocos (Keeling) Island samples, and genetic similarities between some of the island populations. Historical records suggest that introduction of cats to these islands occurred at the time of European exploration and/or in connection with the pearling, whaling and sealing trades early in the 19th century. On-going influx of domestic cats into the feral cat population is apparently causing the Australian mainland populations to be genetically differentiated from those island populations, which likely are remnants of the historically introduced cat genotypes. A mainly European origin of feral cats in Australia, with possible secondary introductions from Asia following the initial establishment of cats in Australia is reasonable. The islands surrounding Australia may represent founding populations and are of particular interest. The results of the study provide an important timeframe for the impact of feral cats on native species in Australia.
Multiple introductions of the dengue vector, Aedes aegypti, into California
Gloria-Soria, Andrea; Evans, Benjamin R.; Kramer, Vicki; Bolling, Bethany G.; Tabachnick, Walter J.; Powell, Jeffrey R.
2017-01-01
The yellow fever mosquito Aedes aegypti inhabits much of the tropical and subtropical world and is a primary vector of dengue, Zika, and chikungunya viruses. Breeding populations of A. aegypti were first reported in California (CA) in 2013. Initial genetic analyses using 12 microsatellites on collections from Northern CA in 2013 indicated the South Central US region as the likely source of the introduction. We expanded genetic analyses of CA A. aegypti by: (a) examining additional Northern CA samples and including samples from Southern CA, (b) including more southern US populations for comparison, and (c) genotyping a subset of samples at 15,698 SNPs. Major results are: (1) Northern and Southern CA populations are distinct. (2) Northern populations are more genetically diverse than Southern CA populations. (3) Northern and Southern CA groups were likely founded by two independent introductions which came from the South Central US and Southwest US/northern Mexico regions respectively. (4) Our genetic data suggest that the founding events giving rise to the Northern CA and Southern CA populations likely occurred before the populations were first recognized in 2013 and 2014, respectively. (5) A Northern CA population analyzed at multiple time-points (two years apart) is genetically stable, consistent with permanent in situ breeding. These results expand previous work on the origin of California A. aegypti with the novel finding that this species entered California on multiple occasions, likely some years before its initial detection. This work has implications for mosquito surveillance and vector control activities not only in California but also in other regions where the distribution of this invasive mosquito is expanding. PMID:28796789
Multiple introductions of the dengue vector, Aedes aegypti, into California.
Pless, Evlyn; Gloria-Soria, Andrea; Evans, Benjamin R; Kramer, Vicki; Bolling, Bethany G; Tabachnick, Walter J; Powell, Jeffrey R
2017-08-01
The yellow fever mosquito Aedes aegypti inhabits much of the tropical and subtropical world and is a primary vector of dengue, Zika, and chikungunya viruses. Breeding populations of A. aegypti were first reported in California (CA) in 2013. Initial genetic analyses using 12 microsatellites on collections from Northern CA in 2013 indicated the South Central US region as the likely source of the introduction. We expanded genetic analyses of CA A. aegypti by: (a) examining additional Northern CA samples and including samples from Southern CA, (b) including more southern US populations for comparison, and (c) genotyping a subset of samples at 15,698 SNPs. Major results are: (1) Northern and Southern CA populations are distinct. (2) Northern populations are more genetically diverse than Southern CA populations. (3) Northern and Southern CA groups were likely founded by two independent introductions which came from the South Central US and Southwest US/northern Mexico regions respectively. (4) Our genetic data suggest that the founding events giving rise to the Northern CA and Southern CA populations likely occurred before the populations were first recognized in 2013 and 2014, respectively. (5) A Northern CA population analyzed at multiple time-points (two years apart) is genetically stable, consistent with permanent in situ breeding. These results expand previous work on the origin of California A. aegypti with the novel finding that this species entered California on multiple occasions, likely some years before its initial detection. This work has implications for mosquito surveillance and vector control activities not only in California but also in other regions where the distribution of this invasive mosquito is expanding.
Study on the lifetime of Mo/Si multilayer optics with pulsed EUV-source at the ETS
NASA Astrophysics Data System (ADS)
Schürmann, Mark; Yulin, Sergiy; Nesterenko, Viatcheslav; Feigl, Torsten; Kaiser, Norbert; Tkachenko, Boris; Schürmann, Max C.
2011-06-01
As EUV lithography is on its way into production stage, studies of optics contamination and cleaning under realistic conditions become more and more important. Due to this fact an Exposure Test Stand (ETS) has been constructed at XTREME technologies GmbH in collaboration with Fraunhofer IOF and with financial support of Intel Corporation. This test stand is equipped with a pulsed DPP source and allows for the simultaneous exposure of several samples. In the standard set-up four samples with an exposed area larger than 35 mm2 per sample can be exposed at a homogeneous intensity of 0.25 mW/mm2. A recent update of the ETS allows for simultaneous exposures of two samples with intensities up to 1.0 mW/mm2. The first application of this alternative set-up was a comparative study of carbon contamination rates induced by EUV radiation from the pulsed source with contamination rates induced by quasicontinuous synchrotron radiation. A modified gas-inlet system allows for the introduction of a second gas to the exposure chamber. This possibility was applied to investigate the efficiency of EUV-induced cleaning with different gas mixtures. In particular the enhancement of EUV-induced cleaning by addition of a second gas to the cleaning gas was studied.
Moore, Diane E.; Lockner, David A.; Kilgore, Brian D.; Beeler, Nicholas M.
2016-09-23
IntroductionMelting occurred during stick-slip faulting of granite blocks sheared at room-dry, room-temperature conditions in a triaxial apparatus at 200–400 megapascals (MPa) confining pressure. Petrographic examinations of melt textures focused largely on the 400-MPa run products. This report presents an overview of the petrographic data collected on those samples, followed by brief descriptions of annotated versions of all the images.Scanning electron microscope (SEM) images of the starting materials and the three examined 400-MPa samples are presented in this report. Secondary-electron (SE) and backscattered-electron (BSE) imaging techniques were used on different samples. The SE images look down on the sawcut surfaces, yielding topographic and three-dimensional textural information. The BSE imaging was done on samples cut to provide cross-sectional views of the glass-filled shear band (or zone) that developed along the sawcut. Brightness in the BSE images increases with increasing mean atomic number of the material. Additional chemical information about the quenched melt and adjoining minerals was obtained using the energy dispersive system of the SEM during BSE examinations. However, the very narrow shear-band thicknesses and common occurrence of very fine lamellar compositional layering limited the usefulness of this technique for estimating melt chemistry.
Azcarate, Silvana M; Savio, Marianela; Smichowski, Patricia; Martinez, Luis D; Camiña, José M; Gil, Raúl A
2015-10-01
A single-step procedure for trace elements analysis of milk samples is presented. Solubilization with small amounts of dymethylformamide (DMF) was assayed prior to inductively coupled plasma mass spectrometry (ICPMS) detection with a high efficiency sample introduction system. All main instrumental conditions were optimized in order to readily introduce the samples without matrix elimination. In order to assess and mitigate matrix effects in the determination of As, Cd, Co, Cu, Eu, Ga, Gd, Ge, Mn, Mo, Nb, Nd, Ni, Pb, Pr, Rb, Sm, S, Sr, Ta, Tb, V, Zn, and Zr, matrix matching calibration with (103)Rh as internal standard (IS) was performed. The obtained limits of detection were between 0.68 (Tb) and 30 (Zn) μg L(-1). For accuracy verification, certified Skim milk powder reference material (BCR 063R) was employed. The developed method was applied to trace elements analysis of commercially available milks. Principal components analysis was used to correlate the content of trace metals with the kind of milk, obtaining a classification according to adults, baby or baby fortified milks. The outcomes highlight a simple and fast approach that could be trustworthy for routine analysis, quality control and traceability of milks. Copyright © 2015 Elsevier B.V. All rights reserved.
Ensemble-Biased Metadynamics: A Molecular Simulation Method to Sample Experimental Distributions
Marinelli, Fabrizio; Faraldo-Gómez, José D.
2015-01-01
We introduce an enhanced-sampling method for molecular dynamics (MD) simulations referred to as ensemble-biased metadynamics (EBMetaD). The method biases a conventional MD simulation to sample a molecular ensemble that is consistent with one or more probability distributions known a priori, e.g., experimental intramolecular distance distributions obtained by double electron-electron resonance or other spectroscopic techniques. To this end, EBMetaD adds an adaptive biasing potential throughout the simulation that discourages sampling of configurations inconsistent with the target probability distributions. The bias introduced is the minimum necessary to fulfill the target distributions, i.e., EBMetaD satisfies the maximum-entropy principle. Unlike other methods, EBMetaD does not require multiple simulation replicas or the introduction of Lagrange multipliers, and is therefore computationally efficient and straightforward in practice. We demonstrate the performance and accuracy of the method for a model system as well as for spin-labeled T4 lysozyme in explicit water, and show how EBMetaD reproduces three double electron-electron resonance distance distributions concurrently within a few tens of nanoseconds of simulation time. EBMetaD is integrated in the open-source PLUMED plug-in (www.plumed-code.org), and can be therefore readily used with multiple MD engines. PMID:26083917
The introduction of spurious models in a hole-coupled Fabry-Perot open resonator
NASA Technical Reports Server (NTRS)
Cook, Jerry D.; Long, Kenwyn J.; Heinen, Vernon O.; Stankiewicz, Norbert
1992-01-01
A hemispherical open resonator has previously been used to make relative comparisons of the surface resistivity of metallic thin-film samples in the submillimeter wavelength region. This resonator is fed from a far-infrared laser via a small coupling hole in the center of the concave spherical mirror. The experimental arrangement, while desirable as a coupling geometry for monitoring weak emissions from the cavity, can lead to the introduction of spurious modes into the cavity. Sources of these modes are identified, and a simple alteration of the experimental apparatus to eliminate such modes is suggested.
Molecular epidemiology of type 1 and 2 dengue viruses in Brazil from 1988 to 2001.
Pires Neto, R J; Lima, D M; de Paula, S O; Lima, C M; Rocco, I M; Fonseca, B A L
2005-06-01
Dengue is a mosquito-borne viral infection that in recent decades has become a major international public health concern. Epidemic dengue fever reemerged in Brazil in 1981. Since 1990 more than one dengue virus serotype has been circulating in this tropical country and increasing rates of dengue hemorrhagic fever and dengue shock syndrome have been detected every year. Some evidence supports the association between the introduction of a new serotype and/or genotype in a region and the appearance of dengue hemorrhagic fever. In order to study the evolutionary relationships and possible detection of the introduction of new dengue virus genotypes in Brazil in the last years, we analyzed partial nucleotide sequences of 52 Brazilian samples of both dengue type 1 and dengue type 2 isolated from 1988 to 2001 from highly endemic regions. A 240-nucleotide-long sequence from the envelope/nonstructural protein 1 gene junction was used for phylogenetic analysis. After comparing the nucleotide sequences originally obtained in this study to those previously studied by others, and analyzing the phylogenetic trees, we conclude that, after the initial introduction of the currently circulating dengue-1 and dengue-2 genotypes in Brazil, there has been no evidence of introduction of new genotypes since 1988. The increasing number of dengue hemorrhagic fever cases seen in Brazil in the last years is probably associated with secondary infections or with the introduction of new serotypes but not with the introduction of new genotypes.
Rejection of an innovation: health information management training materials in east Africa.
Gladwin, J; Dixon, R A; Wilson, T D
2002-12-01
A shift towards decentralization in many low-income countries has meant more skills are demanded of primary health care managers, including data and information handling at all levels of the health care system. Ministries of Health are changing their central reporting health information systems to health management information systems with emphasis on managers utilizing information at the point of collection. This paper reports on a research study to investigate the introduction of new information management strategies intended to promote an informational approach to management at the operational health service level in low-income countries. It aims to understand the process taking place when externally developed training materials (PHC MAP), which are intended to strengthen health management information systems, are introduced to potential users in an east African country. A case study has been undertaken and this research has demonstrated that the dynamic equilibrium approach to organizational change is applicable to the introduction of new information management strategies and management approaches in low-income countries. Although PHC MAP developers envisaged a technical innovation needing implementation, potential users saw the situation as one of organizational change. Contributions to theory have been made and many implications for introducing new information systems or the informational approach to management are identified. This theoretical framework could also facilitate the introduction of future information management innovations and would allow practitioners to perceive the introduction of information management innovations as one of organizational change that needs to be managed. Consequently, issues that may facilitate or inhibit adoption could be identified in advance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reynolds, K.M.; Holsten, E.H.; Werner, R.A.
1995-03-01
SBexpert version 1.0 is a knowledge-based decision-support system for management of spruce beetle developed for use in Microsoft Windows. The users guide provides detailed instructions on the use of all SBexpert features. SBexpert has four main subprograms; introduction, analysis, textbook, and literature. The introduction is the first of the five subtopics in the SBexpert help system. The analysis topic is an advisory system for spruce beetle management that provides recommendation for reducing spruce beetle hazard and risk to spruce stands and is the main analytical topic in SBexpert. The textbook and literature topics provide complementary decision support for analysis.
NASA Astrophysics Data System (ADS)
Menon, Sumithra Sivadas; Baskar, K.; Singh, Shubra
2017-06-01
Hydrogen evolution by overall water splitting has emerged as a potential method for green energy generation due to the introduction of highly efficient photocatalysts active under visible region of spectra. In the present work, we focus on a comparative study of the properties of Ga1-xZnxN1-yOy oxynitride samples synthesized by two techniques and their effect on the sample properties. The samples were prepared by both traditional nitridation technique and solution combustion method. Room temperature photoluminescence studies revealed the introduction of additional energy levels above the valence band which in turns broadens the valence band and subsequently reduces the band gap. The band gap narrowing was further confirmed using diffuse reflectance spectroscopy and Valence band X-ray photoelectron spectroscopy (VB-XPS). It was also realized from VB XPS that the reduction of band gap in both the samples was due to upshift of valence band without affecting the conduction band. The presence of disorder activated modes in the samples was examined using temperature dependent Raman spectroscopy. In this work we corroborate the theoretical prediction reported by Al-Jassim et. al that the bandgap narrowing mechanism in ZnO rich solid solution and GaN rich solid solution is asymmetric and a significant bandgap reduction could be observed for ZnO rich solid solution than GaN rich.
Hassett, Leanne; Simpson, Grahame; Cotter, Rachel; Whiting, Diane; Hodgkinson, Adeline; Martin, Diane
2015-04-01
To investigate whether the introduction of an electronic goals system followed by staff training improved the quality, rating, framing and structure of goals written by a community-based brain injury rehabilitation team. Interrupted time series design. Two interventions were introduced six months apart. The first intervention comprised the introduction of an electronic goals system. The second intervention comprised a staff goal training workshop. An audit protocol was devised to evaluate the goals. A random selection of goal statements from the 12 months prior to the interventions (Time 1 baseline) were compared with all goal statements written after the introduction of the electronic goals system (Time 2) and staff training (Time 3). All goals were de-identified for client and time-period, and randomly ordered. A total of 745 goals (Time 1 n = 242; Time 2 n = 283; Time 3 n = 220) were evaluated. Compared with baseline, the introduction of the electronic goals system alone significantly increased goal rating, framing and structure (χ(2) tests 144.7, 18.9, 48.1, respectively, p < 0.001). The addition of staff training meant that the improvement in goal quality, which was only a trend at Time 2, was statistically significant at Time 3 (χ(2) 15.0, p ≤ 001). The training also led to a further significant increase in the framing and structuring of goals over the electronic goals system (χ(2) 11.5, 12.5, respectively, p ≤ 0.001). An electronic goals system combined with staff training improved the quality, rating, framing and structure of goal statements. © The Author(s) 2014.
A Teacher's Introduction to Remote Sensing.
ERIC Educational Resources Information Center
Kirman, Joseph M.
1997-01-01
Defines remote sensing as the examination of something without touching it. Generally, this refers to satellite and aerial photographic images. Discusses how this technology and resulting knowledge can be integrated into geography classes. Includes a sample unit using images. (MJP)
NASA Astrophysics Data System (ADS)
Moran, J.; Wilcox Freeburg, E.; Kriesel, J.; Linley, T. J.; Kelly, J.; Coleman, M. L.; Christensen, L. E.; Vance, S.
2016-12-01
Spectroscopy-based platforms have recently risen to the forefront for making stable isotope measurements of methane, carbon dioxide, water, or other analytes. These spectroscopy systems can be relatively straightforward to operate (versus a mass spectrometry platform), largely relieve the analyst of mass interference artifacts, and many can be used in the field. Despite these significant advantages, however, existing spectroscopy techniques suffer from a lack of measurement sensitivity that can ultimately limit select applications including spatially resolved and compound-specific measurements. Here we present a capillary absorption spectroscopy (CAS) system that is designed to mitigate sensitivity issues in spectroscopy-based stable isotope evaluation. The system uses mid-wave infrared excitation generated from a continuous wave quantum cascade laser. Importantly, the sample `chamber' is a flexible capillary with a total volume of less than one cc. Proprietary coatings on the internal surface of the fiber improve optical performance, guiding the light to a detector and facilitating high levels of interaction between the laser beam and gaseous analytes. We present data demonstrating that a tapered hollow fiber cell, with an internal diameter that broadens toward the detector, reduces optical feedback to further improve measurement sensitivity. Sensitivity of current hollow fiber / CAS systems enable measurements of only 10's of picomoles CO2 while theoretical improvements should enable measurements of as little as 10's of femtomoles. Continued optimization of sample introduction and improvements to optical feedback are being explored. Software is being designed to provide rapid integration of data and generation of processed isotope measurements using a graphical user interface. Taken together, the sensitivity improvements of the CAS system under development could, when coupled to a laser ablation sampling device, enable up to 2 µm spatial resolution (roughly the size of a eukaryotic cell or multiple prokaryotic cells) or provide a basis for compounds specific stable isotope analysis of trace biomarkers. The small size and low weight of the system holds future potential for field and / or remote deployment.