Sample records for sample introduction technique

  1. Capillary sample introduction of polymerase chain reaction (PCR) products separated in ultrathin slab gels.

    PubMed

    Bullard, K M; Hietpas, P B; Ewing, A G

    1998-01-01

    Polymerase chain reaction (PCR) amplified short tandem repeat (STR) samples from the HUMVWF locus have been analyzed using a unique sample introduction and separation technique. A single capillary is used to transfer samples onto an ultrathin slab gel (57 microm thin). This ultrathin nondenaturing polyacrylamide gel is used to separate the amplified fragments, and laser-induced fluorescence with ethidium bromide is used for detection. The feasibility of performing STR analysis using this system has been investigated by examining the reproducibility for repeated samples. Reproducibility is examined by comparing the migration of the 14 and 17 HUMVWF alleles on three consecutive separations on the ultrathin slab gel. Using one locus, separations match in migration time with the two alleles 42 s apart for each of the three consecutive separations. This technique shows potential to increase sample throughput in STR analysis techniques although separation resolution still needs to be improved.

  2. Direct Liquid Sampling for Corona Discharge Ion Mobility Spectrometry.

    PubMed

    Sabo, Martin; Malásková, Michaela; Harmathová, Olga; Hradski, Jasna; Masár, Marián; Radjenovic, Branislav; Matejčík, Štefan

    2015-07-21

    We present a new technique suitable for direct liquid sampling and analysis by ion mobility spectrometry (IMS). The technique is based on introduction of a droplet stream to the IMS reaction region. The technique was successfully used to detect explosives dissolved in methanol and oil as well as to analyze amino acids and dipeptides. One of the main advantages of this technique is its ability to analyze liquid samples without the requirement of any special solution.

  3. Comparative performance study of different sample introduction techniques for rapid and precise selenium isotope ratio determination using multi-collector inductively coupled plasma mass spectrometry (MC-ICP/MS).

    PubMed

    Elwaer, Nagmeddin; Hintelmann, Holger

    2007-11-01

    The analytical performance of five sample introduction systems, a cross flow nebulizer spray chamber, two different solvent desolvation systems, a multi-mode sample introduction system (MSIS), and a hydride generation (LI2) system were compared for the determination of Se isotope ratio measurements using multi-collector inductively coupled plasma mass spectrometry (MC-ICP/MS). The optimal operating parameters for obtaining the highest Se signal-to-noise (S/N) ratios and isotope ratio precision for each sample introduction were determined. The hydride generation (LI2) system was identified as the most suitable sample introduction method yielding maximum sensitivity and precision for Se isotope ratio measurement. It provided five times higher S/N ratios for all Se isotopes compared to the MSIS, 20 times the S/N ratios of both desolvation units, and 100 times the S/N ratios produced by the conventional spray chamber sample introduction method. The internal precision achieved for the (78)Se/(82)Se ratio at 100 ng mL(-1) Se with the spray chamber, two desolvation, MSIS, and the LI2 systems coupled to MC-ICP/MS was 150, 125, 114, 13, and 7 ppm, respectively. Instrument mass bias factors (K) were calculated using an exponential law correction function. Among the five studied sample introduction systems the LI2 showed the lowest mass bias of -0.0265 and the desolvation system showed the largest bias with -0.0321.

  4. Identification of nonvolatile coal derived products via chromatography coupled with on-line FTIR detection. Quarterly progress report, March 1-May 31, 1985. [C/sub 2/H/sub 2/ extracts of ground coal, coffee and paprika

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, L.T.

    Because it has been our goal to interface the supercritical fluid chromatograph with a Fourier transform infrared spectrometer we have initially chosen packed columns due to their increased sample capacities, and supercritical CO/sub 2/ because of its infrared transparency. This paper compares two sampling techniques that can be utilized in packed column supercritical fluid Chromatography (SFC). Traditional sample introduction is accomplished using an injector with a sample loop. The loop is filled with the appropriate amount of material, and subsequently inserted into the mobile phase path. In most cases the sample must be either dissolved or extracted into an appropriatemore » solvent for such sample introduction. Note that unlike HPLC, where the solvent can be the same as the mobile phase, traditional sampling with SFC must use a solvent that is very different from the mobile phase. As a result, solvent peaks are almost always present, especially with universal detectors like FTIR. An alternative method is described here whereby both extraction of the sample and introduction of the extract onto the column is accomplished on-line using only the supercritical fluid mobile phase. This sampling technique is made possible by a simple valving scheme which ties directly the extraction vessel, the injector, the packed column and the detector. This technique has several advantages over the traditional methods, not the least of which is the absence of a large amount of foreign solvent introduced on the column. 11 refs., 7 figs.« less

  5. Microfluidic evaporator for on-chip sample concentration.

    PubMed

    Casadevall i Solvas, Xavier; Turek, Vladimir; Prodromakis, Themistoklis; Edel, Joshua B

    2012-10-21

    We present a simple technique for the concentration of liquid samples in microfluidic devices applicable for single or multiple-phase configurations. The strategy consists of capturing the sample of interest within microfluidic traps and breaking its continuity by the introduction of a gas phase, which is also used to evaporate it.

  6. Magnetic Susceptibility: A Practical Introduction.

    ERIC Educational Resources Information Center

    Greenaway, A. M.; Trail, L. E.

    1983-01-01

    Describes an experiment in which students: (1) synthesize tris(acetylacetonato)iron(III), tris(diethyldithiocarbamato)iron(III), and chlorobis(diethyldithiocarbmamato)iron(III); (2) are given a sample of potassium hexocyanoferrate(III); and (3) are then asked to measure the room temperature of these samples using the Guoy technique. Background…

  7. Improved format for radiocardiographic data

    NASA Technical Reports Server (NTRS)

    Dimeff, J.; Sevelius, G.

    1973-01-01

    Technique involves introduction of radioactive sample into antecubital vein. Scintillation crystal mounted in collimating housing views portion of right and left hearts. As radioactive sample passes through heart, counting rate is measured by crystal and recorded on strip chart. Data is insensitive to geometric effects and other parameters.

  8. Analytical techniques for identification and study of organic matter in returned lunar samples

    NASA Technical Reports Server (NTRS)

    Burlingame, A. L.

    1974-01-01

    The results of geochemical research are reviewed. Emphasis is placed on the contribution of mass spectrometric data to the solution of specific structural problems. Information on the mass spectrometric behavior of compounds of geochemical interest is reviewed and currently available techniques of particular importance to geochemistry, such as gas chromatograph-mass spectrometer coupling, modern sample introduction methods, and computer application in high resolution mass spectrometry, receive particular attention.

  9. Trace elemental analysis of glass and paint samples of forensic interest by ICP-MS using laser ablation solid sample introduction

    NASA Astrophysics Data System (ADS)

    Almirall, Jose R.; Trejos, Tatiana; Hobbs, Andria; Furton, Kenneth G.

    2003-09-01

    The importance of small amounts of glass and paint evidence as a means to associate a crime event to a suspect or a suspect to another individual has been demonstrated in many cases. Glass is a fragile material that is often found at the scenes of crimes such as burglaries, hit-and-run accidents and violent crime offenses. Previous work has demonstrated the utility of elemental analysis by solution ICP-MS of small amounts of glass for the comparison between a fragment found at a crime scene to a possible source of the glass. The multi-element capability and the sensitivity of ICP-MS combined with the simplified sample introduction of laser ablation prior to ion detection provides for an excellent and relatively non-destructive technique for elemental analysis of glass fragments. The direct solid sample introduction technique of laser ablation (LA) is reported as an alternative to the solution method. Direct solid sampling provides several advantages over solution methods and shows great potential for a number of solid sample analyses in forensic science. The advantages of laser ablation include the simplification of sample preparation, thereby reducing the time and complexity of the analysis, the elimination of handling acid dissolution reagents such as HF and the reduction of sources of interferences in the ionization plasma. Direct sampling also provides for essentially "non-destructive" sampling due to the removal of very small amounts of sample needed for analysis. The discrimination potential of LA-ICP-MS is compared with previously reported solution ICP-MS methods using external calibration with internal standardization and a newly reported solution isotope dilution (ID) method. A total of ninety-one different glass samples were used for the comparison study using the techniques mentioned. One set consisted of forty-five headlamps taken from a variety of automobiles representing a range of twenty years of manufacturing dates. A second set consisted of forty-six automotive glasses (side windows and windshields) representing casework glass from different vehicle manufacturers over several years was also characterized by RI and elemental composition analysis. The solution sample introduction techniques (external calibration and isotope dilution) provide for excellent sensitivity and precision but have the disadvantages of destroying the sample and also involve complex sample preparation. The laser ablation method was simpler, faster and produced comparable discrimination to the EC-ICP-MS and ID-ICP-MS. LA-ICP-MS can provide for an excellent alternative to solution analysis of glass in forensic casework samples. Paints and coatings are frequently encountered as trace evidence samples submitted to forensic science laboratories. A LA-ICP-MS method has been developed to complement the commonly used techniques in forensic laboratories in order to better characterize these samples for forensic purposes. Time-resolved plots of each sample can be compared to associate samples to each other or to discriminate between samples. Additionally, the concentration of lead and the ratios of other elements have been determined in various automotive paints by the reported method. A sample set of eighteen (18) survey automotive paint samples have been analyzed with the developed method in order to determine the utility of LA-ICP-MS and to compare the method to the more commonly used scanning electron microscopy (SEM) method for elemental characterization of paint layers in forensic casework.

  10. Digital signal conditioning for flight test instrumentation

    NASA Technical Reports Server (NTRS)

    Bever, Glenn A.

    1991-01-01

    An introduction to digital measurement processes on aircraft is provided. Flight test instrumentation systems are rapidly evolving from analog-intensive to digital intensive systems, including the use of onboard digital computers. The topics include measurements that are digital in origin, as well as sampling, encoding, transmitting, and storing data. Particular emphasis is placed on modern avionic data bus architectures and what to be aware of when extracting data from them. Examples of data extraction techniques are given. Tradeoffs between digital logic families, trends in digital development, and design testing techniques are discussed. An introduction to digital filtering is also covered.

  11. Estimating Aquatic Insect Populations. Introduction to Sampling.

    ERIC Educational Resources Information Center

    Chihuahuan Desert Research Inst., Alpine, TX.

    This booklet introduces high school and junior high school students to the major groups of aquatic insects and to population sampling techniques. Chapter 1 consists of a short field guide which can be used to identify five separate orders of aquatic insects: odonata (dragonflies and damselflies); ephemeroptera (mayflies); diptera (true flies);…

  12. An introduction to the processes, problems, and management of urban lakes

    USGS Publications Warehouse

    Britton, L.J.; Averett, R.C.; Ferreira, R.F.

    1975-01-01

    As lake studies become more common, sampling techniques for data collection need increased accuracy and consistency, in order to make meaningful comparisons between different lakes. Therefore, the report discusses the main factors involved in conducting lake studies. These factors include the types and frequency of measurements useful in lake reconnaissance studies and a review of literature on sampling equipment and techniques. A glossary of selected terms begins the report, which is intended for guideline use by urban planners and managers.

  13. Comparative study on Ga1-xZnxN1-yOy oxynitride synthesized by different techniques for application in photocatalytic hydrogen production

    NASA Astrophysics Data System (ADS)

    Menon, Sumithra Sivadas; Baskar, K.; Singh, Shubra

    2017-06-01

    Hydrogen evolution by overall water splitting has emerged as a potential method for green energy generation due to the introduction of highly efficient photocatalysts active under visible region of spectra. In the present work, we focus on a comparative study of the properties of Ga1-xZnxN1-yOy oxynitride samples synthesized by two techniques and their effect on the sample properties. The samples were prepared by both traditional nitridation technique and solution combustion method. Room temperature photoluminescence studies revealed the introduction of additional energy levels above the valence band which in turns broadens the valence band and subsequently reduces the band gap. The band gap narrowing was further confirmed using diffuse reflectance spectroscopy and Valence band X-ray photoelectron spectroscopy (VB-XPS). It was also realized from VB XPS that the reduction of band gap in both the samples was due to upshift of valence band without affecting the conduction band. The presence of disorder activated modes in the samples was examined using temperature dependent Raman spectroscopy. In this work we corroborate the theoretical prediction reported by Al-Jassim et. al that the bandgap narrowing mechanism in ZnO rich solid solution and GaN rich solid solution is asymmetric and a significant bandgap reduction could be observed for ZnO rich solid solution than GaN rich.

  14. Introduction to Field Water-Quality Methods for the Collection of Metals - 2007 Project Summary

    USGS Publications Warehouse

    Allen, Monica L.

    2008-01-01

    The U.S. Geological Survey (USGS), Region VI of the U.S. Environmental Protection Agency (USEPA), and the Osage Nation presented three 3-day workshops, in June-August 2007, entitled ?Introduction to Field Water-Quality Methods for the Collection of Metals.? The purpose of the workshops was to provide instruction to tribes within USEPA Region VI on various USGS surface-water measurement methods and water-quality sampling protocols for the collection of surface-water samples for metals analysis. Workshop attendees included members from over 22 tribes and pueblos. USGS instructors came from Oklahoma, New Mexico, and Georgia. Workshops were held in eastern and south-central Oklahoma and New Mexico and covered many topics including presampling preparation, water-quality monitors, and sampling for metals in surface water. Attendees spent one full classroom day learning the field methods used by the USGS Water Resources Discipline and learning about the complexity of obtaining valid water-quality and quality-assurance data. Lectures included (1) a description of metal contamination sources in surface water; (2) introduction on how to select field sites, equipment, and laboratories for sample analysis; (3) collection of sediment in surface water; and (4) utilization of proper protocol and methodology for sampling metals in surface water. Attendees also were provided USGS sampling equipment for use during the field portion of the class so they had actual ?hands-on? experience to take back to their own organizations. The final 2 days of the workshop consisted of field demonstrations of current USGS water-quality sample-collection methods. The hands-on training ensured that attendees were exposed to and experienced proper sampling procedures. Attendees learned integrated-flow techniques during sample collection, field-property documentation, and discharge measurements and calculations. They also used enclosed chambers for sample processing and collected quality-assurance samples to verify their techniques. Benefits of integrated water-quality sample-collection methods are varied. Tribal environmental programs now have the ability to collect data that are comparable across watersheds. The use of consistent sample collection, manipulation, and storage techniques will provide consistent quality data that will enhance the understanding of local water resources. The improved data quality also will help the USEPA better document the condition of the region?s water. Ultimately, these workshops equipped tribes to use uniform sampling methods and to provide consistent quality data that are comparable across the region.

  15. Towards high concentration enhancement of microfluidic temperature gradient focusing of sample solutes using combined AC and DC field induced Joule heating.

    PubMed

    Ge, Zhengwei; Wang, Wei; Yang, Chun

    2011-04-07

    It is challenging to continuously concentrate sample solutes in microfluidic channels. We present an improved electrokinetic technique for enhancing microfluidic temperature gradient focusing (TGF) of sample solutes using combined AC and DC field induced Joule heating effects. The introduction of an AC electric field component services dual functions: one is to produce Joule heat for generating temperature gradient; the other is to suppress electroosmotic flow. Consequently the required DC voltages for achieving sample concentration by Joule heating induced TGF are reduced, thereby leading to smaller electroosmotic flow (EOF) and thus backpressure effects. As a demonstration, the proposed technique can lead to concentration enhancement of sample solutes of more than 2500-fold, which is much higher than the existing literature reported microfluidic concentration enhancement by utilizing the Joule heating induced TGF technique.

  16. "Hitch-Hiking" on Creativity in Nature.

    ERIC Educational Resources Information Center

    Offner, David

    1990-01-01

    An "Introduction to Bionics" course is described, focusing on objectives, the case study method used in the course, a sample case involving the design of a self-locking spine positioner for a catfish, course coverage, idea-generating techniques, and course benefits. (JDD)

  17. Pesticide Multiresidue Analysis in Cereal Grains Using Modified QuEChERS Method Combined with Automated Direct Sample Introduction GC-TOFMS and UPLC-MS/MS Techniques

    USDA-ARS?s Scientific Manuscript database

    The QuEChERS (quick, easy, cheap, effective, rugged, and safe) sample preparation method was modified to accommodate various cereal grain matrices (corn, oat, rice and wheat) and provide good analytical results (recoveries in the range of 70-120% and RSDs <20%) for the majority of the target pestici...

  18. An introduction to metabolomics and its potential application in veterinary science.

    PubMed

    Jones, Oliver A H; Cheung, Victoria L

    2007-10-01

    Metabolomics has been found to be applicable to a wide range of fields, including the study of gene function, toxicology, plant sciences, environmental analysis, clinical diagnostics, nutrition, and the discrimination of organism genotypes. This approach combines high-throughput sample analysis with computer-assisted multivariate pattern-recognition techniques. It is increasingly being deployed in toxico- and pharmacokinetic studies in the pharmaceutical industry, especially during the safety assessment of candidate drugs in human medicine. However, despite the potential of this technique to reduce both costs and the numbers of animals used for research, examples of the application of metabolomics in veterinary research are, thus far, rare. Here we give an introduction to metabolomics and discuss its potential in the field of veterinary science.

  19. MASS MEASUREMENTS BY AN ACCURATE AND SENSITIVE SELECTED ION RECORDING TECHNIQUE

    EPA Science Inventory

    Trace-level components of mixtures were successfully identified or confirmed by mass spectrometric accurate mass measurements, made at high resolution with selected ion recording, using GC and LC sample introduction. Measurements were made at 20 000 or 10 000 resolution, respecti...

  20. Measurement of isotope ratios on transient signals by MC-ICP-MS.

    PubMed

    Günther-Leopold, Ines; Wernli, Beat; Kopajtic, Zlatko; Günther, Detlef

    2004-01-01

    Precise and accurate isotope ratio measurements are an important task in many applications such as isotope-dilution mass spectrometry, bioavailability studies, or the determination of isotope variations in geological or nuclear samples. The technique of MC-ICP-MS has attracted much attention because it permits the precise measurement of isotope compositions for a wide range of elements combined with excellent detection limits due to high ionisation efficiencies. However, the results are based mainly on measurements using continuous sample introduction. In the present study the determination of isotope ratios on various transient signals with a time duration of 30 to 60 s has been achieved by coupling high-performance liquid chromatography to a multicollector inductively coupled plasma mass spectrometer. In order to investigate the origin of ratio drifts across the transient signals for this hyphenated technique, measurements with the same standard solutions were also carried out using a flow-injection device for sample introduction. As a result of this application it could be concluded that the main source of the bias in the measured isotope ratios is within the ICP-MS instead of fractionation effects on the chromatographic column material. Preliminary studies on short transient signals of gaseous samples (dry plasma) showed a reverse fractionation effect compared with wet plasma conditions (flow injection and HPLC).

  1. Tackling sampling challenges in biomolecular simulations.

    PubMed

    Barducci, Alessandro; Pfaendtner, Jim; Bonomi, Massimiliano

    2015-01-01

    Molecular dynamics (MD) simulations are a powerful tool to give an atomistic insight into the structure and dynamics of proteins. However, the time scales accessible in standard simulations, which often do not match those in which interesting biological processes occur, limit their predictive capabilities. Many advanced sampling techniques have been proposed over the years to overcome this limitation. This chapter focuses on metadynamics, a method based on the introduction of a time-dependent bias potential to accelerate sampling and recover equilibrium properties of a few descriptors that are able to capture the complexity of a process at a coarse-grained level. The theory of metadynamics and its combination with other popular sampling techniques such as the replica exchange method is briefly presented. Practical applications of these techniques to the study of the Trp-Cage miniprotein folding are also illustrated. The examples contain a guide for performing these calculations with PLUMED, a plugin to perform enhanced sampling simulations in combination with many popular MD codes.

  2. Engineering Design Handbook: Development Guide for Reliability. Part Three. Reliability Prediction

    DTIC Science & Technology

    1976-01-01

    Populations 4-3 4-7 IFR and DFR Distributions 4-3 CHAPTER 5. SOME ADVANCED MATHEMATICAL TECHNIQUES 5-0 List of Symbols 5-1 5-1 Introduction...Aß,CJE= sets AFyAGSFJBc ~ events that units UA and -\\AAA E{] EB £H T $£ T UB are Failed or Good subsets "of A£,CJ),E s-expected value of...i.e., the sample space is all possible values that can arise. Each value is called a sample point. There are six sample points in the sample space

  3. Concentration and separation of biological organisms by ultrafiltration and dielectrophoresis

    DOEpatents

    Simmons, Blake A.; Hill, Vincent R.; Fintschenko, Yolanda; Cummings, Eric B.

    2010-10-12

    Disclosed is a method for monitoring sources of public water supply for a variety of pathogens by using a combination of ultrafiltration techniques together dielectrophoretic separation techniques. Because water-borne pathogens, whether present due to "natural" contamination or intentional introduction, would likely be present in drinking water at low concentrations when samples are collected for monitoring or outbreak investigations, an approach is needed to quickly and efficiently concentrate and separate particles such as viruses, bacteria, and parasites in large volumes of water (e.g., 100 L or more) while simultaneously reducing the sample volume to levels sufficient for detecting low concentrations of microbes (e.g., <10 mL). The technique is also designed to screen the separated microbes based on specific conductivity and size.

  4. Biotechnical use of polymerase chain reaction for microbiological analysis of biological samples.

    PubMed

    Lantz, P G; Abu al-Soud, W; Knutsson, R; Hahn-Hägerdal, B; Rådström, P

    2000-01-01

    Since its introduction in the mid-80s, polymerase chain reaction (PCR) technology has been recognised as a rapid, sensitive and specific molecular diagnostic tool for the analysis of micro-organisms in clinical, environmental and food samples. Although this technique can be extremely effective with pure solutions of nucleic acids, it's sensitivity may be reduced dramatically when applied directly to biological samples. This review describes PCR technology as a microbial detection method, PCR inhibitors in biological samples and various sample preparation techniques that can be used to facilitate PCR detection, by either separating the micro-organisms from PCR inhibitors and/or by concentrating the micro-organisms to detectable concentrations. Parts of this review are updated and based on a doctoral thesis by Lantz [1] and on a review discussing methods to overcome PCR inhibition in foods [2].

  5. Ozone Modulation/Membrane Introduction Mass Spectrometry for Analysis of Hydrocarbon Pollutants in Air

    NASA Astrophysics Data System (ADS)

    Atkinson, D. B.

    2001-12-01

    Modulation of volatile hydrocarbons in two-component mixtures is demonstrated using an ozonolysis pretreatment with membrane introduction mass spectrometry (MIMS). The MIMS technique allows selective introduction of volatile and semivolatile analytes into a mass spectrometer via processes known collectively as pervaporation [Kotiaho and Cooks, 1992]. A semipermeable polymer membrane acts as an interface between the sample (vapor or solution) and the vacuum of the mass spectrometer. This technique has been demonstrated to allow for sensitive analysis of hydrocarbons and other non-polar volatile organic compounds (VOC`s) in air samples[Cisper et al., 1995] . The methodology has the advantages of no sample pretreatment and short analysis time, which are promising for online monitoring applications but the chief disadvantage of lack of a separation step for the different analytes in a mixture. Several approaches have been investigated to overcome this problem including use of selective chemical ionization [Bier and Cooks, 1987] and multivariate calibration techniques[Ketola et al., 1999] . A new approach is reported for the quantitative measurement of VOCs in complex matrices. The method seeks to reduce the complexity of mass spectra observed in hydrocarbon mixture analysis by selective pretreatment of the analyte mixture. In the current investigation, the rapid reaction of ozone with alkenes is used, producing oxygenated compounds which are suppressed by the MIMS system. This has the effect of removing signals due to unsaturated analytes from the compound mass spectra, and comparison of the spectra before and after the ozone treatment reveals the nature of the parent compounds. In preliminary investigations, ozone reacted completely with cyclohexene from a mixture of cylohexene and cyclohexane, and with β -pinene from a mixture of toluene and β -pinene, suppressing the ion signals from the olefins. A slight attenuation of the cyclohexane and toluene in those mixtures was also observed. Despite this problem, the hydrocarbon signal response can be calibrated and the method can be used for quantitative analysis of volatile hydrocarbon compounds in air samples. This methodology should augment the efficiency of the MIMS approach in online and onsite monitoring of VOC emissions. Bier, M.R., and R.G. Cooks, Membrane Interface for Selective Introduction of Volatile Compounds Directly into The Ionization Chamber of a Mass Spectrometer, Anal. Chem., 59 (4), 597, 1987. Cisper, M.E., C.G. Gill, L.E. Townsend, and P.H. Hemberger, On-Line Detection of Volatile Organic Compounds in Air at Parts-per-Trillion Levels by Membrane Introduction Mass Spectrometry, Anal. Chem., 67 (8), 1413-1417, 1995. Ketola, R.A., M. Ojala, and J. Heikkonen, A Non-linear Asymmetric Error Function-based Least Mean Square Approach for the Analysis of Multicomponent Mass Spectra Measured by Membrane Inlet Mass Spectrometry, Rapid Commun. Mass Spectrom., 13 (8), 654, 1999. Kotiaho, T., and R.G. Cooks, Membrane Introduction Mass Spectrometry in Environmental Analysis, in: J.J. Breen, M. J. Dellarco, (Eds), Pollution in Industrial processes, 126 pp., ACS Symp. Ser., Washington, D.C. 508, 1992.

  6. The Hit and Away technique: optimal usage of the ultrasonic scalpel in laparoscopic gastrectomy.

    PubMed

    Irino, Tomoyuki; Hiki, Naoki; Ohashi, Manabu; Nunobe, Souya; Sano, Takeshi; Yamaguchi, Toshiharu

    2016-01-01

    Thermal injury and unexpected bleeding caused by ultrasonic scalpels can lead to fatal complications in laparoscopic gastrectomy (LG), such as postoperative pancreatic fistulas (POPF). In this study, we developed the "Hit and Away" protocol for optimal usage of the ultrasonic scalpel, which in essence involves dividing tissues and vessels in batches using the tip of the scalpel to control tissue temperature. To assess the effectiveness of the technique, the surface temperature of the mesocolon of female swine after ultrasonic scalpel activations was measured, and tissue samples were collected to evaluate microscopic thermal injury to the pancreas. In parallel, we retrospectively surveyed 216 patients who had undergone LG before or after the introduction of this technique and assessed the ability of this technique to reduce POPF. The tissue temperature of the swine mesocolon reached 43 °C, a temperature at which adipose tissue melted but fibrous tissue, including vessels, remained intact. The temperature returned to baseline within 3 s of turning off the ultrasonic scalpel, demonstrating the advantage of using ultrasonic scalpel in a pulsatile manner. Tissue samples from the pancreas demonstrated that the extent of thermal injury post-procedure was limited to the capsule of the pancreas. Moreover, with respect to the clinical outcomes before and after the introduction of this technique, POPF incidence decreased significantly from 7.8 to 1.0% (p = 0.021). The "Hit and Away" technique can reduce blood loss and thermal injury to the pancreas and help to ensure the safety of lymph node dissection in LG.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Korte, Andrew R

    This thesis presents efforts to improve the methodology of matrix-assisted laser desorption ionization-mass spectrometry imaging (MALDI-MSI) as a method for analysis of metabolites from plant tissue samples. The first chapter consists of a general introduction to the technique of MALDI-MSI, and the sixth and final chapter provides a brief summary and an outlook on future work.

  8. Microcomputer Processing and Analysis of Sample Survey in Education. A Methodological Case Study.

    ERIC Educational Resources Information Center

    Guo, Sheng

    This report discusses the methods, techniques, and software applications used in processing the data gathered in a survey of the physical condition and health of students in Guangdong Province, China. The introduction provides background on the survey. Survey grouping, data items, and survey procedures are then described. A discussion of…

  9. Flow-based analysis using microfluidics-chemiluminescence systems.

    PubMed

    Al Lawati, Haider A J

    2013-01-01

    This review will discuss various approaches and techniques in which analysis using microfluidics-chemiluminescence systems (MF-CL) has been reported. A variety of applications is examined, including environmental, pharmaceutical, biological, food and herbal analysis. Reported uses of CL reagents, sample introduction techniques, sample pretreatment methods, CL signal enhancement and detection systems are discussed. A hydrodynamic pumping system is predominately used for these applications. However, several reports are available in which electro-osmotic (EO) pumping has been implemented. Various sample pretreatment methods have been used, including liquid-liquid extraction, solid-phase extraction and molecularly imprinted polymers. A wide range of innovative techniques has been reported for CL signal enhancement. Most of these techniques are based on enhancement of the mixing process in the microfluidics channels, which leads to enhancement of the CL signal. However, other techniques are also reported, such as mirror reaction, liquid core waveguide, on-line pre-derivatization and the use of an opaque white chip with a thin transparent seal. Photodetectors are the most commonly used detectors; however, other detection systems have also been used, including integrated electrochemiluminescence (ECL) and organic photodiodes (OPDs). Copyright © 2012 John Wiley & Sons, Ltd.

  10. The recognition of female voice based on voice registers in singing techniques in real-time using hankel transform method and macdonald function

    NASA Astrophysics Data System (ADS)

    Meiyanti, R.; Subandi, A.; Fuqara, N.; Budiman, M. A.; Siahaan, A. P. U.

    2018-03-01

    A singer doesn’t just recite the lyrics of a song, but also with the use of particular sound techniques to make it more beautiful. In the singing technique, more female have a diverse sound registers than male. There are so many registers of the human voice, but the voice registers used while singing, among others, Chest Voice, Head Voice, Falsetto, and Vocal fry. Research of speech recognition based on the female’s voice registers in singing technique is built using Borland Delphi 7.0. Speech recognition process performed by the input recorded voice samples and also in real time. Voice input will result in weight energy values based on calculations using Hankel Transformation method and Macdonald Functions. The results showed that the accuracy of the system depends on the accuracy of sound engineering that trained and tested, and obtained an average percentage of the successful introduction of the voice registers record reached 48.75 percent, while the average percentage of the successful introduction of the voice registers in real time to reach 57 percent.

  11. Method for concentration and separation of biological organisms by ultrafiltration and dielectrophoresis

    DOEpatents

    Simmons, Blake A.; Hill, Vincent R.; Fintschenko, Yolanda; Cummings, Eric B.

    2012-09-04

    Disclosed is a method for monitoring sources of public water supply for a variety of pathogens by using a combination of ultrafiltration techniques together dielectrophoretic separation techniques. Because water-borne pathogens, whether present due to "natural" contamination or intentional introduction, would likely be present in drinking water at low concentrations when samples are collected for monitoring or outbreak investigations, an approach is needed to quickly and efficiently concentrate and separate particles such as viruses, bacteria, and parasites in large volumes of water (e.g., 100 L or more) while simultaneously reducing the sample volume to levels sufficient for detecting low concentrations of microbes (e.g., <10 mL). The technique is also designed to screen the separated microbes based on specific conductivity and size.

  12. An Undergraduate Experiment for the Measurement of Perfluorinated Surfactants in Fish Liver by Liquid Chromatography-Tandem Mass Spectrometry

    ERIC Educational Resources Information Center

    Stock, Naomi L.; Martin, Jonathan W.; Ye, Yun; Mabury, Scott A.

    2007-01-01

    A laboratory experiment that provides students a hands-on introduction to the specific techniques of liquid chromatography-tandem mass spectrometry (LC-MS/MS) and electrospray ionization is presented. The students can thus practice the analytical principles of sample extraction, detection, quantification, and quality control using a fresh fish…

  13. Selected Guidelines for the Management of Records and Archives: A RAMP Reader.

    ERIC Educational Resources Information Center

    Walne, Peter, Comp.

    The guidelines contained in this book are taken from studies published by UNESCO's Records and Archives Management Program (RAMP) between 1981 and 1987. Each set of guidelines is accompanied by an introduction to provide chronological or methodological context. The guidelines are titled as follows: (1) "The Use of Sampling Techniques in the…

  14. Inductively Coupled Plasma Optical Emission Spectrometry for Rare Earth Elements Analysis

    NASA Astrophysics Data System (ADS)

    He, Man; Hu, Bin; Chen, Beibei; Jiang, Zucheng

    2017-01-01

    Inductively coupled plasma optical emission spectrometry (ICP-OES) merits multielements capability, high sensitivity, good reproducibility, low matrix effect and wide dynamic linear range for rare earth elements (REEs) analysis. But the spectral interference in trace REEs analysis by ICP-OES is a serious problem due to the complicated emission spectra of REEs, which demands some correction technology including interference factor method, derivative spectrum, Kalman filtering algorithm and partial least-squares (PLS) method. Matrix-matching calibration, internal standard, correction factor and sample dilution are usually employed to overcome or decrease the matrix effect. Coupled with various sample introduction techniques, the analytical performance of ICP-OES for REEs analysis would be improved. Compared with conventional pneumatic nebulization (PN), acid effect and matrix effect are decreased to some extent in flow injection ICP-OES, with higher tolerable matrix concentration and better reproducibility. By using electrothermal vaporization as sample introduction system, direct analysis of solid samples by ICP-OES is achieved and the vaporization behavior of refractory REEs with high boiling point, which can easily form involatile carbides in the graphite tube, could be improved by using chemical modifier, such as polytetrafluoroethylene and 1-phenyl-3-methyl-4-benzoyl-5-pyrazone. Laser ablation-ICP-OES is suitable for the analysis of both conductive and nonconductive solid samples, with the absolute detection limit of ng-pg level and extremely low sample consumption (0.2 % of that in conventional PN introduction). ICP-OES has been extensively employed for trace REEs analysis in high-purity materials, and environmental and biological samples.

  15. Sampling Methods in Cardiovascular Nursing Research: An Overview.

    PubMed

    Kandola, Damanpreet; Banner, Davina; O'Keefe-McCarthy, Sheila; Jassal, Debbie

    2014-01-01

    Cardiovascular nursing research covers a wide array of topics from health services to psychosocial patient experiences. The selection of specific participant samples is an important part of the research design and process. The sampling strategy employed is of utmost importance to ensure that a representative sample of participants is chosen. There are two main categories of sampling methods: probability and non-probability. Probability sampling is the random selection of elements from the population, where each element of the population has an equal and independent chance of being included in the sample. There are five main types of probability sampling including simple random sampling, systematic sampling, stratified sampling, cluster sampling, and multi-stage sampling. Non-probability sampling methods are those in which elements are chosen through non-random methods for inclusion into the research study and include convenience sampling, purposive sampling, and snowball sampling. Each approach offers distinct advantages and disadvantages and must be considered critically. In this research column, we provide an introduction to these key sampling techniques and draw on examples from the cardiovascular research. Understanding the differences in sampling techniques may aid nurses in effective appraisal of research literature and provide a reference pointfor nurses who engage in cardiovascular research.

  16. Flow injection gas chromatography with sulfur chemiluminescence detection for the analysis of total sulfur in complex hydrocarbon matrixes.

    PubMed

    Hua, Yujuan; Hawryluk, Myron; Gras, Ronda; Shearer, Randall; Luong, Jim

    2018-01-01

    A fast and reliable analytical technique for the determination of total sulfur levels in complex hydrocarbon matrices is introduced. The method employed flow injection technique using a gas chromatograph as a sample introduction device and a gas phase dual-plasma sulfur chemiluminescence detector for sulfur quantification. Using the technique described, total sulfur measurement in challenging hydrocarbon matrices can be achieved in less than 10 s with sample-to-sample time <2 min. The high degree of selectivity and sensitivity toward sulfur compounds of the detector offers the ability to measure low sulfur levels with a detection limit in the range of 20 ppb w/w S. The equimolar response characteristic of the detector allows the quantitation of unknown sulfur compounds and simplifies the calibration process. Response is linear over a concentration range of five orders of magnitude, with a high degree of repeatability. The detector's lack of response to hydrocarbons enables direct analysis without the need for time-consuming sample preparation and chromatographic separation processes. This flow injection-based sulfur chemiluminescence detection technique is ideal for fast analysis or trace sulfur analysis. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Current Trends in Ubiquitous Biosensing

    DTIC Science & Technology

    2013-08-01

    fundamental advances have been made in the synergistic combination of research in the fields of microfluidics and optics, coined “optofluidics” [24-26...microfabrication and clean-room techniques for the development of microfluidic devices [27]. Advances in the rapid fabrication of nano- and microfluidic ...Transduction Microfluidic Processing Sample Introduction Optofluidics Enabled Bio-Sensing A B C Figure 4: (A) Schematic diagram of optofluidic tomography

  18. Self-Efficacy, Risk-Taking Behavior and Mental Health as Predictors of Personal Growth Initiative among University Undergraduates

    ERIC Educational Resources Information Center

    Ogunyemi, Ajibola O.; Mabekoje, Sesan Ola

    2007-01-01

    Introduction: This study sought to determine the combined and relative efficacy of self-efficacy, risk-taking behaviour and mental health on personal growth initiative of university undergraduates. Method: The expo-facto research design was used to conduct the study. Stratified random sampling technique was used to select 425 participants from 6…

  19. Effect of sputtering power on MgF2 thin films deposited by sputtering technique under fluorine trapping

    NASA Astrophysics Data System (ADS)

    De, Rajnarayan; Haque, S. Maidul; Tripathi, S.; Prathap, C.; Rao, K. Divakar; Sahoo, N. K.

    2016-05-01

    A non-conventional magnetron sputtering technique was explored to deposit magnesium fluoride thin films using the concept of fluorine gas trapping without the introduction of additional fluorine gas flow inside the chamber. The effect of magnetron power from 50 W to 250 W has been explored on structural, optical and physical properties of the samples. Polycrystalline nature with tetragonal crystallinity of the films has been confirmed by GIXRD measurements along with thickness dependency. Monotonic increase of attenuation coefficient (k) with RF power has been explained in terms of target compound dissociation probability. In conclusion, with fluorine trapping method, the samples deposited at lower RF powers (<100 W) are found to be more suitable for optical applications.

  20. Nanometer-sized ceria-coated silica-iron oxide for the reagentless microextraction/preconcentration of heavy metals in environmental and biological samples followed by slurry introduction to ICP-OES.

    PubMed

    Dados, A; Paparizou, E; Eleftheriou, P; Papastephanou, C; Stalikas, C D

    2014-04-01

    A slurry suspension sampling technique is developed and optimized for the rapid microextraction of heavy metals and analysis using nanometer-sized ceria-coated silica-iron oxide particles and inductively coupled plasma optical emission spectrometry (ICP-OES). Magnetic-silica material is synthesized by a co-precipitation and sol-gel method followed by ceria coating through a precipitation. The large particles are removed using a sedimentation-fractionation procedure and a magnetic homogeneous colloidal suspension of ceria-modified iron oxide-silica is produced for microextraction. The nanometer-sized particles are separated from the sample solution magnetically and analyzed with ICP-OES using a slurry suspension sampling approach. The ceria-modified iron oxide-silica does not contain any organic matter and this probably justifies the absence of matrix effect on plasma atomization capacity, when increased concentrations of slurries are aspirated. The As, Be, Mo, Cr, Cu, Pb, Hg, Sb, Se and V can be preconcentrated by the proposed method at pH 6.0 while Mn, Cd, Co and Ni require a pH ≥ 8.0. Satisfactory values are obtained for the relative standard deviations (2-6%), recoveries (88-102%), enrichment factors (14-19) and regression correlation coefficients as well as detectability, at sub-μg L(-1) levels. The applicability of magnetic ceria for the microextraction of metal ions in combination with the slurry introduction technique using ICP is substantiated by the analysis of environmental water and urine samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Thermo-optical properties and nonlinear optical response of smectic liquid crystals containing gold nanoparticles.

    PubMed

    de Melo, P B; Nunes, A M; Omena, L; do Nascimento, S M S; da Silva, M G A; Meneghetti, M R; de Oliveira, I N

    2015-10-01

    The present work is devoted to the study of the thermo-optical and nonlinear optical properties of smectic samples containing gold nanoparticles with different shapes. By using the time-resolved Z-scan technique, we determine the effects of nanoparticle addition on the critical behavior of the thermal diffusivity and thermo-optical coefficient at the vicinity of the smectic-A-nematic phase transition. Our results reveal that introduction of gold nanoparticles affects the temperature dependence of thermo-optical parameters, due to the local distortions in the orientational order and heat generation provided by guest particles during the laser exposure. Further, we show that a nonlinear optical response may take place at temperatures where the smectic order is well established. We provide a detailed discussion of the effects associated with the introduction gold nanoparticles on the mechanisms behind the thermal transport and optical nonlinearity in liquid-crystal samples.

  2. Gunshot residue (GSR) analysis by single particle inductively coupled plasma mass spectrometry (spICP-MS).

    PubMed

    Heringer, Rodrigo D; Ranville, James F

    2018-05-25

    Single particle inductively coupled plasma mass spectrometry (spICP-MS) was investigated as a screening-level technique for the analysis and characterization of inorganic gunshot residue (IGSR) nanoparticles. spICP-MS works with undigested samples whereby nanoparticles (NPs) in a suspension are individually atomized and ionized as they reach the plasma, each resulting in a pulse of analyte ions that can be quantified. The method is rapid, and signals from hundreds of NPs can be collected in 1-2min per sample. The technique is quantitative for NP mass and number concentration when only one element (single element mode) is measured using a quadrupole MS. Likewise, a qualitative elemental fingerprint can be obtained for individual NPs when peak-hopping between two elements (dual element mode). For this proof of concept study, each shooter's hand was sampled with ultrapure water or swab to obtain NPs suspensions. Measurements of antimony, barium, and lead were performed using both analysis modes. With no sample preparation and fully automated sample introduction, it is possible to analyze more than 100 samples in a day. Results show that this technique opens a new perspective for future research on GSR sample identification and characterization and can complement SEM/EDX analysis. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Gas chromatography/ion mobility spectrometry as a hyphenated technique for improved explosives detection and analysis

    NASA Technical Reports Server (NTRS)

    Mercado, AL; Marsden, Paul

    1995-01-01

    Ion Mobility Spectrometry (IMS) is currently being successfully applied to the problem of on-line trace detection of plastic and other explosives in airports and other facilities. The methods of sample retrieval primarily consist of batch sampling for particulate residue on a filter card for introduction into the IMS. The sample is desorbed into the IMS using air as the carrier and negative ions of the explosives are detected, some as an adduct with a reagent ion such as Cl(-). Based on studies and tests conducted by different airport authorities, this method seems to work well for low vapor pressure explosives such as RDX and PETN, as well as TNT that are highly adsorptive and can be found in nanogram quantities on contaminated surfaces. Recently, the changing terrorist threat and the adoption of new marking agents for plastic explosives has meant that the sample introduction and analysis capabilities of the IMS must be enhanced in order to keep up with other detector developments. The IMS has sufficient analytical resolution for a few threat compounds but the IMS Plasmogram becomes increasingly more difficult to interpret when the sample mixture gets more complex.

  4. [Recent Development of Atomic Spectrometry in China].

    PubMed

    Xiao, Yuan-fang; Wang, Xiao-hua; Hang, Wei

    2015-09-01

    As an important part of modern analytical techniques, atomic spectrometry occupies a decisive status in the whole analytical field. The development of atomic spectrometry also reflects the continuous reform and innovation of analytical techniques. In the past fifteen years, atomic spectrometry has experienced rapid development and been applied widely in many fields in China. This review has witnessed its development and remarkable achievements. It contains several directions of atomic spectrometry, including atomic emission spectrometry (AES), atomic absorption spectrometry (AAS), atomic fluorescence spectrometry (AFS), X-ray fluorescence spectrometry (XRF), and atomic mass spectrometry (AMS). Emphasis is put on the innovation of the detection methods and their applications in related fields, including environmental samples, biological samples, food and beverage, and geological materials, etc. There is also a brief introduction to the hyphenated techniques utilized in atomic spectrometry. Finally, the prospects of atomic spectrometry in China have been forecasted.

  5. Fluid control structures in microfluidic devices

    DOEpatents

    Mathies, Richard A.; Grover, William H.; Skelley, Alison; Lagally, Eric; Liu, Chung N.

    2008-11-04

    Methods and apparatus for implementing microfluidic analysis devices are provided. A monolithic elastomer membrane associated with an integrated pneumatic manifold allows the placement and actuation of a variety of fluid control structures, such as structures for pumping, isolating, mixing, routing, merging, splitting, preparing, and storing volumes of fluid. The fluid control structures can be used to implement a variety of sample introduction, preparation, processing, and storage techniques.

  6. Evaluation of a rapid diagnostic field test kit for identification of Phytophthora ramorum, P. kernoviae and other Phytophthora species at the point of inspection

    Treesearch

    C.R. Lane; E. Hobden; L. Laurenson; V.C. Barton; K.J.D. Hughes; H. Swan; N. Boonham; A.J. Inman

    2008-01-01

    Plant health regulations to prevent the introduction and spread of Phytophthora ramorum and P. kernoviae require rapid, cost effective diagnostic methods for screening large numbers of plant samples at the time of inspection. Current on-site techniques require expensive equipment, considerable expertise and are not suited for plant...

  7. Fluid control structures in microfluidic devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mathies, Richard A.; Grover, William H.; Skelley, Alison

    2017-05-09

    Methods and apparatus for implementing microfluidic analysis devices are provided. A monolithic elastomer membrane associated with an integrated pneumatic manifold allows the placement and actuation of a variety of fluid control structures, such as structures for pumping, isolating, mixing, routing, merging, splitting, preparing, and storing volumes of fluid. The fluid control structures can be used to implement a variety of sample introduction, preparation, processing, and storage techniques.

  8. Fluid control structures in microfluidic devices

    NASA Technical Reports Server (NTRS)

    Skelley, Alison (Inventor); Mathies, Richard A. (Inventor); Lagally, Eric (Inventor); Grover, William H. (Inventor); Liu, Chung N. (Inventor)

    2008-01-01

    Methods and apparatus for implementing microfluidic analysis devices are provided. A monolithic elastomer membrane associated with an integrated pneumatic manifold allows the placement and actuation of a variety of fluid control structures, such as structures for pumping, isolating, mixing, routing, merging, splitting, preparing, and storing volumes of fluid. The fluid control structures can be used to implement a variety of sample introduction, preparation, processing, and storage techniques.

  9. Hydrogen-related defects in Al2O3 layers grown on n-type Si by the atomic layer deposition technique

    NASA Astrophysics Data System (ADS)

    Kolkovsky, Vl.; Stübner, R.

    2018-04-01

    The electrical properties of alumina films with thicknesses varying from 15 nm to 150 nm, grown by the atomic layer deposition technique on n-type Si, were investigated. We demonstrated that the annealing of the alumina layers in argon (Ar) or hydrogen (H) atmosphere at about 700 K resulted in the introduction of negatively charged defects irrespective of the type of the substrate. These defects were also observed in samples subjected to a dc H plasma treatment at temperatures below 400 K, whereas they were not detected in as-grown samples and in samples annealed in Ar atmosphere at temperatures below 400 K. The concentration of these defects increased with a higher H content in the alumina films. In good agreement with theory we assigned these defects to interstitial H-related defects.

  10. Three Proposed Compendia for Genesis Solar Wind Samples: Science Results, Collector Materials Characterization and Cleaning Techniques

    NASA Technical Reports Server (NTRS)

    Allton, J. H.; Calaway, M. J.; Nyquist, L. E.; Jurewicz, A. J. G.; Burnett, D. S.

    2018-01-01

    Final Paper and not the abstract is attached. Introduction: Planetary material and cosmochemistry research using Genesis solar wind samples (including the development and implementation of cleaning and analytical techniques) has matured sufficiently that compilations on several topics, if made publically accessible, would be beneficial for researchers and reviewers. We propose here three compendia based on content, organization and source of documents (e.g. published peer-reviewed, published, internal memos, archives). For planning purposes, suggestions are solicited from potential users of Genesis solar wind samples for the type of science content and/or organizational style that would be most useful to them. These compendia are proposed as living documents, periodically updated. Similar to the existing compendia described below, the curation compendia are like library or archival finding aids, they are guides to published or archival documents and should not be cited as primary sources.

  11. Determination of Caffeine and Other Purine Compounds in Food and Pharmaceuitcals by Micellar Electrokinetic Chrmoatography

    NASA Astrophysics Data System (ADS)

    Vogt, Carla; Contradi, S.; Rohde, E.

    1997-09-01

    Capillary elctrophoresis is a modern separation technique, especially the extremely high efficiencies and minimal requirements with regard to buffers, samples and solvents lead to a dramatic increase of applications in the last few years. This paper offers an introduction to the technique of micellar elektrokinetic chromatography as a special kind of capillary electrophoresis. Caffeine and other purine compounds have been determined in foodstuff (tea, coffee, cocoa) as well as in pharmaceutical formulations. Different sample preparation procedures which have been developed with regard to the special properties of the sample matrices are discussed in the paper.This preparation facilitates the separation in many cases. So students have to solve a relatively simple separation problem by variation of buffer pH, buffer components and separation parameters. By doing a calibration for the analyzed purine compounds they will learn about reproducibility in capillary electrophoresis.

  12. Improving microstructural quantification in FIB/SEM nanotomography.

    PubMed

    Taillon, Joshua A; Pellegrinelli, Christopher; Huang, Yi-Lin; Wachsman, Eric D; Salamanca-Riba, Lourdes G

    2018-01-01

    FIB/SEM nanotomography (FIB-nt) is a powerful technique for the determination and quantification of the three-dimensional microstructure in subsurface features. Often times, the microstructure of a sample is the ultimate determiner of the overall performance of a system, and a detailed understanding of its properties is crucial in advancing the materials engineering of a resulting device. While the FIB-nt technique has developed significantly in the 15 years since its introduction, advanced nanotomographic analysis is still far from routine, and a number of challenges remain in data acquisition and post-processing. In this work, we present a number of techniques to improve the quality of the acquired data, together with easy-to-implement methods to obtain "advanced" microstructural quantifications. The techniques are applied to a solid oxide fuel cell cathode of interest to the electrochemistry community, but the methodologies are easily adaptable to a wide range of material systems. Finally, results from an analyzed sample are presented as a practical example of how these techniques can be implemented. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Elemental and isotopic imaging of biological samples using NanoSIMS.

    PubMed

    Kilburn, Matt R; Clode, Peta L

    2014-01-01

    With its low detection limits and the ability to analyze most of the elements in the periodic table, secondary ion mass spectrometry (SIMS) represents one of the most versatile in situ analytical techniques available, and recent developments have resulted in significant advantages for the use of imaging mass spectrometry in biological and biomedical research. Increases in spatial resolution and sensitivity allow detailed interrogation of samples at relevant scales and chemical concentrations. Advances in dynamic SIMS, specifically with the advent of NanoSIMS, now allow the tracking of stable isotopes within biological systems at subcellular length scales, while static SIMS combines subcellular imaging with molecular identification. In this chapter, we present an introduction to the SIMS technique, with particular reference to NanoSIMS, and discuss its application in biological and biomedical research.

  14. X-Ray photoelectron Spectroscopy Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engelhard, Mark H.; Droubay, Timothy C.; Du, Yingge

    2017-01-03

    With capability for obtaining quantitative elemental composition, chemical and electronic state, and overlayer thickness information from the top ~10 nm of a sample surface, X-ray Photoelectron Spectroscopy (XPS) or Electron Spectroscopy for Chemical Analysis (ESCA) is a versatile and widely used technique for analyzing surfaces. The technique is applied to a host of materials, from insulators to conductors in virtually every scientific field and sub-discipline. More recently, XPS has been extended under in-situ and operando conditions. Following a brief introduction to XPS principles and instrument components, this article exemplifies widely ranging XPS applications in material and life sciences.

  15. Isotope dilution ICP-MS with laser-assisted sample introduction for direct determination of sulfur in petroleum products.

    PubMed

    Boulyga, Sergei F; Heilmann, Jens; Heumann, Klaus G

    2005-08-01

    Inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with direct laser-assisted introduction of isotope-diluted samples into the plasma, using a laser ablation system with high ablation rates, was developed for accurate sulfur determinations in different petroleum products such as 'sulfur-free' premium gasoline, diesel fuel, and heating oil. Two certified gas oil reference materials were analyzed for method validation. Two different 34S-enriched spike compounds, namely, elementary sulfur dissolved in xylene and dibenzothiophene in hexane, were synthesized and tested for their usefulness in this isotope dilution technique. The isotope-diluted sample was adsorbed on a filter-paper-like material, which was fixed in a special holder for irradiation by the laser beam. Under these conditions no time-dependent spike/analyte fractionation was only observed for the dibenzothiophene spike during the laser ablation process, which means that the measured 34S/32S isotope ratio of the isotope-diluted sample remained constant-a necessary precondition for accurate results with the isotope dilution technique. A comparison of LA-ICP-IDMS results with the certified values of the gas oil reference materials and with results obtained from ICP-IDMS analyses with wet sample digestion demonstrated the accuracy of the new LA-ICP-IDMS method in the concentration range of 9.2 microg g(-1) ('sulfur-free' premium gasoline) to 10.4 mg g(-1) (gas oil reference material BCR 107). The detection limit for sulfur by LA-ICP-IDMS is 0.04 microg g(-1) and the analysis time is only about 10 min, which therefore also qualifies this method for accurate determinations of low sulfur contents in petroleum products on a routine level.

  16. High-Temperature Lubricant Analyses Using the System for Thermal Diagnostic Studies (STDS). A Feasibility Study

    DTIC Science & Technology

    1990-07-01

    permeation chromatography (GPC) have been applied to lubricant type samples. 8 Most recently the newly introduced supercritical fluid chromatography (SFC... fluids , such as lubricants and hydraulic fluids can also be examined using various inverse chromatography procedures. Another mode, known as reaction...introduction of new gaseous extraction techniques, e.g., supercritical fluid extraction, procedures such as IGC will probably be developed for vastly

  17. English-as-a-Second-Language Programs in Basic Skills Education Program 1

    DTIC Science & Technology

    1984-01-01

    languages and English as a second language . These theories and findings have led, in turn, to the development of new methods for teaching languages ...INTRODUCTION TO TEACHING TECHNIQUES FOR ENGLISH AS A SECOND LANGUAGE . . . . . . . . . . . . 9 Introduction ............................. 9 Traditional Methods ...instruments. q8 . _. ,’,..8 4% .’ II. A BRIEF INTRODUCTION TO TEACHING TECHNIQUES FOR ENGLISH

  18. Development of a rapid screening technique for organochlorine pesticides using solvent microextraction (SME) and fast gas chromatography (GC).

    PubMed

    de Jager, L S; Andrews, A R

    2000-11-01

    A novel, fast screening method for organochlorine pesticides (OCPs) in water samples has been developed. Total analysis time was less than 9 min, allowing 11 samples to be screened per hour. The relatively new technique of solvent microextraction (SME) was used to extract and preconcentrate the pesticides into a single drop of hexane. The use of a conventional carbon dioxide cryotrap was investigated for introduction of the extract onto a micro-bore (0.1 mm) capillary column for fast GC analysis. A pulsed-discharge electron capture detector was used which yielded selective and sensitive measurement of the pesticide peaks. Fast GC conditions were optimised and tested with the previously developed SME procedure. Calibration curves yielded good linearity and concentrations down to 0.25 ng mL-1 were detectable with RSD values ranging from 12.0 to 28% and LOD for most OCPs at 0.25 ng mL-1. Spiked river water samples were tested and using the developed screen we were able to differentiate between spiked samples and samples containing no OCPs.

  19. Applications of surface analytical techniques in Earth Sciences

    NASA Astrophysics Data System (ADS)

    Qian, Gujie; Li, Yubiao; Gerson, Andrea R.

    2015-03-01

    This review covers a wide range of surface analytical techniques: X-ray photoelectron spectroscopy (XPS), scanning photoelectron microscopy (SPEM), photoemission electron microscopy (PEEM), dynamic and static secondary ion mass spectroscopy (SIMS), electron backscatter diffraction (EBSD), atomic force microscopy (AFM). Others that are relatively less widely used but are also important to the Earth Sciences are also included: Auger electron spectroscopy (AES), low energy electron diffraction (LEED) and scanning tunnelling microscopy (STM). All these techniques probe only the very top sample surface layers (sub-nm to several tens of nm). In addition, we also present several other techniques i.e. Raman microspectroscopy, reflection infrared (IR) microspectroscopy and quantitative evaluation of minerals by scanning electron microscopy (QEMSCAN) that penetrate deeper into the sample, up to several μm, as all of them are fundamental analytical tools for the Earth Sciences. Grazing incidence synchrotron techniques, sensitive to surface measurements, are also briefly introduced at the end of this review. (Scanning) transmission electron microscopy (TEM/STEM) is a special case that can be applied to characterisation of mineralogical and geological sample surfaces. Since TEM/STEM is such an important technique for Earth Scientists, we have also included it to draw attention to the capability of TEM/STEM applied as a surface-equivalent tool. While this review presents most of the important techniques for the Earth Sciences, it is not an all-inclusive bibliography of those analytical techniques. Instead, for each technique that is discussed, we first give a very brief introduction about its principle and background, followed by a short section on approaches to sample preparation that are important for researchers to appreciate prior to the actual sample analysis. We then use examples from publications (and also some of our known unpublished results) within the Earth Sciences to show how each technique is applied and used to obtain specific information and to resolve real problems, which forms the central theme of this review. Although this review focuses on applications of these techniques to study mineralogical and geological samples, we also anticipate that researchers from other research areas such as Material and Environmental Sciences may benefit from this review.

  20. Trace elements determination in seawater by ICP-MS with on-line pre-concentration on a Chelex-100 column using a ‘standard’ instrument setup.

    PubMed Central

    Søndergaard, Jens; Asmund, Gert; Larsen, Martin M.

    2015-01-01

    Trace element determination in seawater is analytically challenging due to the typically very low concentrations of the trace elements and the potential interference of the salt matrix. A common way to address the challenge is to pre-concentrate the trace elements on a chelating resin, then rinse the matrix elements from the resin and subsequently elute and detect the trace elements using inductively coupled plasma mass spectrometry (ICP-MS). This technique typically involves time-consuming pre-treatment of the samples for ‘off-line’ analyses or complicated sample introduction systems involving several pumps and valves for ‘on-line’ analyses. As an alternative, the following method offers a simple method for ‘on-line’ analyses of seawater by ICP-MS. As opposed to previous methods, excess seawater was pumped through the nebulizer of the ICP-MS during the pre-concentration step but the gas flow was adjusted so that the seawater was pumped out as waste without being sprayed into the instrument. Advantages of the method include: • Simple and convenient analyses of seawater requiring no changes to the ‘standard’ sample introduction system except from a resin-filled micro-column connected to the sample tube. The ‘standard’ sample introduction system refers to that used for routine digest-solution analyses of biota and sediment by ICP-MS using only one peristaltic pump; and • Accurate determination of the elements V, Mn, Co, Ni, Cu, Zn, Cd and Pb in a range of different seawater matrices verified by participation in 6 successive rounds of the international laboratory intercalibration program QUASIMEME. PMID:26258050

  1. Analysis of high-purity germanium dioxide by ETV-ICP-AES with preliminary concentration of trace elements.

    PubMed

    Medvedev, Nickolay S; Shaverina, Anastasiya V; Tsygankova, Alphiya R; Saprykin, Anatoly I

    2016-08-01

    The paper presents a combined technique of germanium dioxide analysis by inductively coupled plasma atomic emission spectrometry (ICP-AES) with preconcentration of trace elements by distilling off matrix and electrothermal (ETV) introduction of the trace elements concentrate into the ICP. Evaluation of metrological characteristics of the developed technique of high-purity germanium dioxide analysis was performed. The limits of detection (LODs) for 25 trace elements ranged from 0.05 to 20ng/g. The accuracy of proposed technique is confirmed by "added-found" («or spiking») experiment and comparing the results of ETV-ICP-AES and ICP-AES analysis of high purity germanium dioxide samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. The use of environmental DNA in invasive species surveillance of the Great Lakes commercial bait trade.

    PubMed

    Nathan, Lucas R; Jerde, Christopher L; Budny, Michelle L; Mahon, Andrew R

    2015-04-01

    Over 180 non-native species have been introduced in the Laurentian Great Lakes region, many posing threats to native species and ecosystem functioning. One potential pathway for introductions is the commercial bait trade; unknowing or unconcerned anglers commonly release unused bait into aquatic systems. Previous surveillance efforts of this pathway relied on visual inspection of bait stocks in retail shops, which can be time and cost prohibitive and requires a trained individual that can rapidly and accurately identify cryptic species. Environmental DNA (eDNA) surveillance, a molecular tool that has been used for surveillance in aquatic environments, can be used to efficiently detect species at low abundances. We collected and analyzed 576 eDNA samples from 525 retail bait shops throughout the Laurentian Great Lake states. We used eDNA techniques to screen samples for multiple aquatic invasive species (AIS) that could be transported in the bait trade, including bighead (Hypophthalmichthys nobilis) and silver carp (H. molitrix), round goby (Neogobius melanostomus), tubenose goby (Proterorhinus marmoratus), Eurasian rudd (Scardinius erythrophthalmus), and goldfish (Carassius auratus). Twenty-seven samples were positive for at least one target species (4.7% of samples), and all target species were found at least once, except bighead carp. Despite current regulations, the bait trade remains a potential pathway for invasive species introductions in the Great Lakes region. Alterations to existing management strategies regarding the collection, transportation, and use of live bait are warranted, including new and updated regulations, to prevent future introductions of invasive species in the Great Lakes via the bait trade. © 2014 Society for Conservation Biology.

  3. Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples

    PubMed Central

    Chen, Ping-Hung; Chen, Shun-Niang; Tseng, Sheng-Hao; Deng, Ming-Jay; Lin, Yang-Wei; Sun, Yuh-Chang

    2016-01-01

    This paper describes a fabrication protocol for a dipole-assisted solid phase extraction (SPE) microchip available for trace metal analysis in water samples. A brief overview of the evolution of chip-based SPE techniques is provided. This is followed by an introduction to specific polymeric materials and their role in SPE. To develop an innovative dipole-assisted SPE technique, a chlorine (Cl)-containing SPE functionality was implanted into a poly(methyl methacrylate) (PMMA) microchip. Herein, diverse analytical techniques including contact angle analysis, Raman spectroscopic analysis, and laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) analysis were employed to validate the utility of the implantation protocol of the C-Cl moieties on the PMMA. The analytical results of the X-ray absorption near-edge structure (XANES) analysis also demonstrated the feasibility of the Cl-containing PMMA used as an extraction medium by virtue of the dipole-ion interactions between the highly electronegative C-Cl moieties and the positively charged metal ions. PMID:27584954

  4. Knudsen Cell Studies of Ti-Al Thermodynamics

    NASA Technical Reports Server (NTRS)

    Jacobson, Nathan S.; Copland, Evan H.; Mehrotra, Gopal M.; Auping, Judith; Gray, Hugh R. (Technical Monitor)

    2002-01-01

    In this paper we describe the Knudsen cell technique for measurement of thermodynamic activities in alloys. Numerous experimental details must be adhered to in order to obtain useful experimental data. These include introduction of an in-situ standard, precise temperature measurement, elimination of thermal gradients, and precise cell positioning. Our first design is discussed and some sample data on Ti-Al alloys is presented. The second modification and associated improvements are also discussed.

  5. Introduction of a dermatophyte polymerase chain reaction assay to the diagnostic mycology service in Scotland.

    PubMed

    Alexander, C L; Shankland, G S; Carman, W; Williams, C

    2011-05-01

    Dermatophytes are the major cause of superficial mycoses in samples submitted to Clinical Mycology, Glasgow. The most prevalent species is Trichophyton rubrum as identified classically by microscopy and culture. Recent advances in polymerase chain reaction (PCR) technology were examined for the feasibility of introducing a T. rubrum real-time PCR assay into a routine diagnostic service. To improve the diagnostic mycology service by the introduction of a real-time PCR test for T. rubrum. The DNA from 4972 nail and skin samples was obtained using the Qiagen QIAsymphony automated extractor. This DNA was subjected to real-time PCR using T. rubrum-specific primers and a probe. During phase 1 of the study, 862 samples were analysed; 446 of 470 specimens that grew T. rubrum were detected by PCR. Out of 4110 samples analysed during phase 2, 753 T. rubrum infections were diagnosed and reported within 72 h. A total of 3357 samples were negative for a fungal infection by PCR and microscopy; these were also reported within 72 h. A vast reduction in the turnaround times can be achieved using this technique as opposed to classical methods. Samples which are PCR negative but microscopy positive are still subjected to culture. Screening samples for their suitability for PCR prior to processing eliminates the application of PCR for T. rubrum on inappropriate samples such those from the scalp or pityriasis versicolor. © 2011 The Authors. BJD © 2011 British Association of Dermatologists.

  6. Comparison of laser and power bleaching techniques in tooth color change.

    PubMed

    Fekrazad, Reza; Alimazandarani, Shervin; Kalhori, Katayoun Am; Assadian, Hadi; Mirmohammadi, Seyed-Mahdi

    2017-04-01

    Laser-assisted bleaching uses laser beam to accelerate release of free radicals within the bleaching gel to decrease time of whitening procedure. The aim of this study was to compare the efficacy of power bleaching using Opalescence Xtra Boost® and laser bleaching technique using LaserSmile gel and diode laser as an activator in their tooth whitening capacity. Student t test showed that the laser bleaching group significantly outperformed the power bleaching group in changing ∆E ( p =0.977). Similarly, while comparing the groups in changing ∆L, the laser bleaching group indicated significantly superior results ( p =0.953). Statistical data from student t test while comparing the groups in changing the parameter of yellowness indicated that samples in laser bleaching group underwent a more significant reduction than power-bleached samples ( p =0.85). Correspondingly, changes in whiteness were statistically tested through student t test, showing that laser bleaching technique increased whiteness of the samples significantly more than those treated by power bleaching ( p =0.965). The digital color evaluation data was in accordance with spectrophotometry and showed that laser bleaching outperformed power bleaching technique. Both techniques were able to increase whiteness and decrease yellowness ratio of the samples. ΔE decrease for laser bleaching and power bleaching groups were 3.05 and 1.67, respectively. Tooth color change in laser bleaching group was 1.88 times more than that of power bleaching group ( p <0.001). It could be concluded that under the conditions of this study, both laser-assisted and power bleaching techniques were capable of altering tooth color change, but laser bleaching was deemed a more efficient technique in this regard. Key words: Laser, power bleaching, tooth color introduction.

  7. Spatially resolved δ13C analysis using laser ablation isotope ratio mass spectrometry

    NASA Astrophysics Data System (ADS)

    Moran, J.; Riha, K. M.; Nims, M. K.; Linley, T. J.; Hess, N. J.; Nico, P. S.

    2014-12-01

    Inherent geochemical, organic matter, and microbial heterogeneity over small spatial scales can complicate studies of carbon dynamics through soils. Stable isotope analysis has a strong history of helping track substrate turnover, delineate rhizosphere activity zones, and identifying transitions in vegetation cover, but most traditional isotope approaches are limited in spatial resolution by a combination of physical separation techniques (manual dissection) and IRMS instrument sensitivity. We coupled laser ablation sampling with isotope measurement via IRMS to enable spatially resolved analysis over solid surfaces. Once a targeted sample region is ablated the resulting particulates are entrained in a helium carrier gas and passed through a combustion reactor where carbon is converted to CO2. Cyrotrapping of the resulting CO2 enables a reduction in carrier gas flow which improves overall measurement sensitivity versus traditional, high flow sample introduction. Currently we are performing sample analysis at 50 μm resolution, require 65 ng C per analysis, and achieve measurement precision consistent with other continuous flow techniques. We will discuss applications of the laser ablation IRMS (LA-IRMS) system to microbial communities and fish ecology studies to demonstrate the merits of this technique and how similar analytical approaches can be transitioned to soil systems. Preliminary efforts at analyzing soil samples will be used to highlight strengths and limitations of the LA-IRMS approach, paying particular attention to sample preparation requirements, spatial resolution, sample analysis time, and the types of questions most conducive to analysis via LA-IRMS.

  8. Microfluidic-Based sample chips for radioactive solutions

    DOE PAGES

    Tripp, J. L.; Law, J. D.; Smith, T. E.; ...

    2015-01-01

    Historical nuclear fuel cycle process sampling techniques required sample volumes ranging in the tens of milliliters. The radiation levels experienced by analytical personnel and equipment, in addition to the waste volumes generated from analysis of these samples, have been significant. These sample volumes also impacted accountability inventories of required analytes during process operations. To mitigate radiation dose and other issues associated with the historically larger sample volumes, a microcapillary sample chip was chosen for further investigation. The ability to obtain microliter volume samples coupled with a remote automated means of sample loading, tracking, and transporting to the analytical instrument wouldmore » greatly improve analytical efficiency while reducing both personnel exposure and radioactive waste volumes. Sample chip testing was completed to determine the accuracy, repeatability, and issues associated with the use of microfluidic sample chips used to supply µL sample volumes of lanthanide analytes dissolved in nitric acid for introduction to an analytical instrument for elemental analysis.« less

  9. Ammonia modification of activated carbon to enhance carbon dioxide adsorption: Effect of pre-oxidation

    NASA Astrophysics Data System (ADS)

    Shafeeyan, Mohammad Saleh; Daud, Wan Mohd Ashri Wan; Houshmand, Amirhossein; Arami-Niya, Arash

    2011-02-01

    A commercial granular activated carbon (GAC) was subjected to thermal treatment with ammonia for obtaining an efficient carbon dioxide (CO2) adsorbent. In general, CO2 adsorption capacity of activated carbon can be increased by introduction of basic nitrogen functionalities onto the carbon surface. In this work, the effect of oxygen surface groups before introduction of basic nitrogen functionalities to the carbon surface on CO2 adsorption capacity was investigated. For this purpose two different approaches of ammonia treatment without preliminary oxidation and amination of oxidized samples were studied. Modified carbons were characterized by elemental analysis and Fourier Transform Infrared spectroscopy (FT-IR) to study the impact of changes in surface chemistry and formation of specific surface groups on adsorption properties. The texture of the samples was characterized by conducting N2 adsorption/desorption at -196 °C. CO2 capture performance of the samples was investigated using a thermogravimetric analysis (TGA). It was found that in both modification techniques, the presence of nitrogen functionalities on carbon surface generally increased the CO2 adsorption capacity. The results indicated that oxidation followed by high temperature ammonia treatment (800 °C) considerably enhanced the CO2 uptake at higher temperatures.

  10. Introduction

    NASA Astrophysics Data System (ADS)

    Kirby, Evan N.

    2018-06-01

    Dwarf galaxies are excellent laboratories of chemical evolution. Many dwarf galaxies have simple star formation histories with very low average star formation rates. These conditions simplify models of chemical evolution and facilitate the identification of sites of nucleosynthesis. Dwarf galaxies also host extremely metal-poor stars, which sample the ejecta of the first generations of supernovae in the universe. This meeting-in-a-meeting, "Stellar Abundances in Dwarf Galasxies," will recognize the importance of dwarf galaxies in learning about the creation and evolution of the elements. Topics include: * the most metal-poor stars * the connection between dwarf galaxies and the Milky Way halo * dwarf galaxies as the paragons of r-process nucleosynthesis * modern techniques in stellar abundance measurements * recent advances in chemical evolution modelingI will give a very brief introduction to set the stage for the meeting.

  11. A Technique for Thermal Desorption Analyses Suitable for Thermally-Labile, Volatile Compounds.

    PubMed

    Alborn, Hans T

    2018-02-01

    Many plant and insect interactions are governed by odors released by the plants or insects and there exists a continual need for new or improved methods to collect and identify these odors. Our group has for some time studied below-ground, plant-produced volatile signals affecting nematode and insect behavior. The research requires repeated sampling of volatiles of intact plant/soil systems in the laboratory as well as the field with the help of probes to minimize unwanted effects on the systems we are studying. After evaluating solid adsorbent filters with solvent extraction or solid phase micro extraction fiber sample collection, we found dynamic sampling of small air volumes on Tenax TA filters followed by thermal desorption sample introduction to be the most suitable analytical technique for our applications. Here we present the development and evaluation of a low-cost and relatively simple thermal desorption technique where a cold trap cooled with liquid carbon dioxide is added as an integral part of a splitless injector. Temperature gradient-based focusing and low thermal mass minimizes aerosol formation and eliminates the need for flash heating, resulting in low sample degradation comparable to solvent-based on-column injections. Additionally, since the presence of the cold trap does not affect normal splitless injections, on-the-fly switching between splitless and thermal desorption modes can be used for external standard quantification.

  12. Phase stability of zirconium oxide films during focused ion beam milling

    NASA Astrophysics Data System (ADS)

    Baxter, Felicity; Garner, Alistair; Topping, Matthew; Hulme, Helen; Preuss, Michael; Frankel, Philipp

    2018-06-01

    Focused ion beam (FIB) is a widely used technique for preparation of electron transparent samples and so it is vital to understand the potential for introduction of FIB-induced microstructural artefacts. The bombardment of both Xe+ and Ga+ ions is observed to cause extensive monoclinic to tetragonal phase transformation in ZrO2 corrosion films, however, this effect is diminished with reduced energy and is not observed below 5 KeV. This study emphasises the importance of careful FIB sample preparation with a low energy cleaning step, and also gives insight into the stabilisation mechanism of the tetragonal phase during oxidation.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Witte, Travis

    This dissertation provides a general introduction to Inductively coupled plasma-mass spectrometry (ICP-MS) and laser ablation (LA) sampling, with an examination of analytical challenges in the employment of this technique. It discusses the origin of metal oxide ions (MO+) in LA-ICP-MS, as well as the effect of introducing helium and nitrogen to the aerosol gas flow on the formation of these polyatomic interferences. It extends the study of polyatomic ions in LA-ICP-MS to metal argide (MAr+) species, an additional source of possible significant interferences in the spectrum. It describes the application of fs-LA-ICP-MS to the determination of uranium isotope ratios inmore » particulate samples.« less

  14. Development of a split-flow system for high precision variable sample introduction in supercritical fluid chromatography.

    PubMed

    Sakai, Miho; Hayakawa, Yoshihiro; Funada, Yasuhiro; Ando, Takashi; Fukusaki, Eiichiro; Bamba, Takeshi

    2017-09-15

    In this study, we propose a novel variable sample injection system based on full-loop injection, named the split-flow sample introduction system, for application in supercritical fluid chromatography (SFC). In this system, the mobile phase is split by the differential pressure between two back pressure regulators (BPRs) after full-loop injection suitable for SFC, and this differential pressure determines the introduction rate. Nine compounds with a wide range of characteristics were introduced with high reproducibility and universality, confirming that a robust variable sample injection system was achieved. We also investigated the control factors of our proposed system. Sample introduction was controlled by the ratio between the column-side pressure drops in splitless and split flow, ΔP columnsideinsplitless and ΔP columnsideinsplit , respectively, where ΔP columnsideinsplitless is related to the mobile phase flow rate and composition and the column resistance. When all other conditions are kept constant, increasing the make-up flow induces an additional pressure drop on the column side of the system, which leads to a reduced column-side flow rate, and hence decreased the amount of sample injected, even when the net pressure drop on the column side remains the same. Thus, sample introduction could be highly controlled at low sample introduction rate, regardless of the introduction conditions. This feature is advantageous because, as a control factor, the solvent in the make-up pump is independent of the column-side pressure drop. Copyright © 2017. Published by Elsevier B.V.

  15. X-ray elemental mapping techniques for elucidating the ecophysiology of hyperaccumulator plants.

    PubMed

    van der Ent, Antony; Przybyłowicz, Wojciech J; de Jonge, Martin D; Harris, Hugh H; Ryan, Chris G; Tylko, Grzegorz; Paterson, David J; Barnabas, Alban D; Kopittke, Peter M; Mesjasz-Przybyłowicz, Jolanta

    2018-04-01

    Contents Summary 432 I. Introduction 433 II. Preparation of plant samples for X-ray micro-analysis 433 III. X-ray elemental mapping techniques 438 IV. X-ray data analysis 442 V. Case studies 443 VI. Conclusions 446 Acknowledgements 449 Author contributions 449 References 449 SUMMARY: Hyperaccumulators are attractive models for studying metal(loid) homeostasis, and probing the spatial distribution and coordination chemistry of metal(loid)s in their tissues is important for advancing our understanding of their ecophysiology. X-ray elemental mapping techniques are unique in providing in situ information, and with appropriate sample preparation offer results true to biological conditions of the living plant. The common platform of these techniques is a reliance on characteristic X-rays of elements present in a sample, excited either by electrons (scanning/transmission electron microscopy), protons (proton-induced X-ray emission) or X-rays (X-ray fluorescence microscopy). Elucidating the cellular and tissue-level distribution of metal(loid)s is inherently challenging and accurate X-ray analysis places strict demands on sample collection, preparation and analytical conditions, to avoid elemental redistribution, chemical modification or ultrastructural alterations. We compare the merits and limitations of the individual techniques, and focus on the optimal field of applications for inferring ecophysiological processes in hyperaccumulator plants. X-ray elemental mapping techniques can play a key role in answering questions at every level of metal(loid) homeostasis in plants, from the rhizosphere interface, to uptake pathways in the roots and shoots. Further improvements in technological capabilities offer exciting perspectives for the study of hyperaccumulator plants into the future. © 2017 University of Queensland. New Phytologist © 2017 New Phytologist Trust.

  16. Advanced Curation Protocols for Mars Returned Sample Handling

    NASA Astrophysics Data System (ADS)

    Bell, M.; Mickelson, E.; Lindstrom, D.; Allton, J.

    Introduction: Johnson Space Center has over 30 years experience handling precious samples which include Lunar rocks and Antarctic meteorites. However, we recognize that future curation of samples from such missions as Genesis, Stardust, and Mars S mple Return, will require a high degree of biosafety combined witha extremely low levels of inorganic, organic, and biological contamination. To satisfy these requirements, research in the JSC Advanced Curation Lab is currently focused toward two major areas: preliminary examination techniques and cleaning and verification techniques . Preliminary Examination Techniques : In order to minimize the number of paths for contamination we are exploring the synergy between human &robotic sample handling in a controlled environment to help determine the limits of clean curation. Within the Advanced Curation Laboratory is a prototype, next-generation glovebox, which contains a robotic micromanipulator. The remotely operated manipulator has six degrees-of- freedom and can be programmed to perform repetitive sample handling tasks. Protocols are being tested and developed to perform curation tasks such as rock splitting, weighing, imaging, and storing. Techniques for sample transfer enabling more detailed remote examination without compromising the integrity of sample science are also being developed . The glovebox is equipped with a rapid transfer port through which samples can be passed without exposure. The transfer is accomplished by using a unique seal and engagement system which allows passage between containers while maintaining a first seal to the outside environment and a second seal to prevent the outside of the container cover and port door from becoming contaminated by the material being transferred. Cleaning and Verification Techniques: As part of the contamination control effort, innovative cleaning techniques are being identified and evaluated in conjunction with sensitive cleanliness verification methods. Towards this end, cleaning techniques such as ultrasonication in ultra -pure water (UPW), oxygen (O2) plasma, and carbon dioxide (CO2) "snow" are being used to clean a variety of different contaminants on a variety of different surfaces. Additionally, once cleaned, techniques to directly verify the s rface cleanliness are being developed. Theseu include X ray photoelectron spectroscopy (XPS) quantification, and screening with- contact angle measure ments , which can be correlated with XPS standards. Methods developed in the Advanced Curation Laboratory will determine the extent to which inorganic and biological contamination can be controlled and minimized.

  17. From inverse problems to learning: a Statistical Mechanics approach

    NASA Astrophysics Data System (ADS)

    Baldassi, Carlo; Gerace, Federica; Saglietti, Luca; Zecchina, Riccardo

    2018-01-01

    We present a brief introduction to the statistical mechanics approaches for the study of inverse problems in data science. We then provide concrete new results on inferring couplings from sampled configurations in systems characterized by an extensive number of stable attractors in the low temperature regime. We also show how these result are connected to the problem of learning with realistic weak signals in computational neuroscience. Our techniques and algorithms rely on advanced mean-field methods developed in the context of disordered systems.

  18. Positioning an Interactive Telecourse in Business.

    ERIC Educational Resources Information Center

    Garland, Barbara C.; Schwinghammer, JoAnn K. L.

    1987-01-01

    The authors describe pedagogical techniques based on one and a half years of planning and executing the introduction of a graduate marketing management telecourse. They focus on issues of positioning strategy that arose during the introduction and on the pedagogical techniques that were used to handle them. (CH)

  19. Laser-desorption tandem time-of-flight mass spectrometry with continuous liquid introduction

    NASA Astrophysics Data System (ADS)

    Williams, Evan R.; Jones, Glenn C., Jr.; Fang, LiLing; Nagata, Takeshi; Zare, Richard N.

    1992-05-01

    A new method to combine aqueous sample introduction with matrix assisted laser desorption mass spectrometry (MS) for interfacing liquid-chromatographic techniques, such as capillary electrophoresis, to MS is described. Aqueous sample solution is introduced directly into the ion source of a time-of-. flight (TOF) mass spectrometer through a fused silica capillary; evaporative cooling results in ice formation at the end of the capillary. The ice can be made to extrude continuously by using localized resistive heating. With direct laser desorption, molecular ions from proteins as large as bovine insulin (5734 Da) can be produced. Two-step desorption/photoionization with a variety of wavelengths is demonstrated, and has the advantages of improved resolution and shot-to-shot reproducibility. Ion structural information is obtained using surface-induced dissociation with an in-line collision device in the reflectron mirror of the TOF instrument. Product ion resolution of ~70 is obtained at m/z77. Extensive fragmentation can be produced with dissociation efficiencies between 7-15% obtained for molecular ions of small organic molecules. Efficiencies approaching 30% are obtained for larger peptide ions.

  20. Synthesis and characterization of structural and magnetic properties of polyaniline-cobalt ferrite (PA-CoFe) nanocomposites

    NASA Astrophysics Data System (ADS)

    Thakur, Sonika; Kaur, Parminder; Singh, Lakhwant

    2018-05-01

    The growing interest in the investigation of the properties of modified conducting polymers stems from their potential applications in various fields such as in sensing and catalytic devices. The present work reports the modification of conducting polymer polyaniline with cobalt ferrite (CoFe) nanoparticles, where CoFe nanoparticles are added in different successive weight percents. The composite samples were synthesized by in-situ chemical oxidative polymerization technique. The density of the samples has been found to increase with an increase in the CoFe content. Structural analysis of the synthesized sample has been done using X-ray diffraction studies. Perusal of the hysteresis curves of the prepared samples depicts that the introduction of CoFe into the polymer matrix leads to enhancement in the ferromagnetic behavior of the synthesized samples, suggesting that these nanocomposites have excellent microwave absorbing capacity.

  1. The Computer in Educational Decision Making. An Introduction and Guide for School Administrators.

    ERIC Educational Resources Information Center

    Sanders, Susan; And Others

    This text provides educational administrators with a working knowledge of the problem-solving techniques of PERT (planning, evaluation, and review technique), Linear Programming, Queueing Theory, and Simulation. The text includes an introduction to decision-making and operations research, four chapters consisting of indepth explanations of each…

  2. Continuous Liquid-Sample Introduction for Bunsen Burner Atomic Emission Spectrometry.

    ERIC Educational Resources Information Center

    Smith, Gregory D.; And Others

    1995-01-01

    Describes a laboratory-constructed atomic emission spectrometer with modular instrumentation components and a simple Bunsen burner atomizer with continuous sample introduction. A schematic diagram and sample data are provided. (DDR)

  3. Method and apparatus for transport, introduction, atomization and excitation of emission spectrum for quantitative analysis of high temperature gas sample streams containing vapor and particulates without degradation of sample stream temperature

    DOEpatents

    Eckels, David E.; Hass, William J.

    1989-05-30

    A sample transport, sample introduction, and flame excitation system for spectrometric analysis of high temperature gas streams which eliminates degradation of the sample stream by condensation losses.

  4. Nonuniform sampling and non-Fourier signal processing methods in multidimensional NMR

    PubMed Central

    Mobli, Mehdi; Hoch, Jeffrey C.

    2017-01-01

    Beginning with the introduction of Fourier Transform NMR by Ernst and Anderson in 1966, time domain measurement of the impulse response (the free induction decay, FID) consisted of sampling the signal at a series of discrete intervals. For compatibility with the discrete Fourier transform (DFT), the intervals are kept uniform, and the Nyquist theorem dictates the largest value of the interval sufficient to avoid aliasing. With the proposal by Jeener of parametric sampling along an indirect time dimension, extension to multidimensional experiments employed the same sampling techniques used in one dimension, similarly subject to the Nyquist condition and suitable for processing via the discrete Fourier transform. The challenges of obtaining high-resolution spectral estimates from short data records using the DFT were already well understood, however. Despite techniques such as linear prediction extrapolation, the achievable resolution in the indirect dimensions is limited by practical constraints on measuring time. The advent of non-Fourier methods of spectrum analysis capable of processing nonuniformly sampled data has led to an explosion in the development of novel sampling strategies that avoid the limits on resolution and measurement time imposed by uniform sampling. The first part of this review discusses the many approaches to data sampling in multidimensional NMR, the second part highlights commonly used methods for signal processing of such data, and the review concludes with a discussion of other approaches to speeding up data acquisition in NMR. PMID:25456315

  5. Thermal inactivation of enzymes and pathogens in biosamples for MS analysis.

    PubMed

    Ahnoff, Martin; Cazares, Lisa H; Sköld, Karl

    2015-01-01

    Protein denaturation is the common basis for enzyme inactivation and inactivation of pathogens, necessary for preservation and safe handling of biosamples for downstream analysis. While heat-stabilization technology has been used in proteomic and peptidomic research since its introduction in 2009, the advantages of using the technique for simultaneous pathogen inactivation have only recently been addressed. The time required for enzyme inactivation by heat (≈1 min) is short compared with chemical treatments, and inactivation is irreversible in contrast to freezing. Heat stabilization thus facilitates mass spectrometric studies of biomolecules with a fast conversion rate, and expands the chemical space of potential biomarkers to include more short-lived entities, such as phosphorylated proteins, in tissue samples as well as whole-blood (dried blood sample) samples.

  6. The Introduction of Crystallographic Concepts Using Lap-Dissolve Slide Techniques.

    ERIC Educational Resources Information Center

    Bodner, George M.; And Others

    1980-01-01

    Describes a method using lap-dissolve slide techniques with two or more slide projectors focused on a single screen for presenting visual effects that show structural features in extended arrays of atoms, or ions involving up to several hundred atoms. Presents an outline of an introduction to the structures of crystalline solids. (CS)

  7. An Enzymatic Clinical Chemistry Laboratory Experiment Incorporating an Introduction to Mathematical Method Comparison Techniques

    ERIC Educational Resources Information Center

    Duxbury, Mark

    2004-01-01

    An enzymatic laboratory experiment based on the analysis of serum is described that is suitable for students of clinical chemistry. The experiment incorporates an introduction to mathematical method-comparison techniques in which three different clinical glucose analysis methods are compared using linear regression and Bland-Altman difference…

  8. Measurement and Visualization of Mass Transport for the Flowing Atmospheric Pressure Afterglow (FAPA) Ambient Mass-Spectrometry Source

    PubMed Central

    Pfeuffer, Kevin P.; Ray, Steven J.; Hieftje, Gary M.

    2014-01-01

    Ambient desorption/ionization mass spectrometry (ADI-MS) has developed into an important analytical field over the last nine years. The ability to analyze samples under ambient conditions while retaining the sensitivity and specificity of mass spectrometry has led to numerous applications and a corresponding jump in the popularity of this field. Despite the great potential of ADI-MS, problems remain in the areas of ion identification and quantification. Difficulties with ion identification can be solved through modified instrumentation, including accurate-mass or MS/MS capabilities for analyte identification. More difficult problems include quantification due to the ambient nature of the sampling process. To characterize and improve sample volatilization, ionization, and introduction into the mass-spectrometer interface, a method of visualizing mass transport into the mass spectrometer is needed. Schlieren imaging is a well-established technique that renders small changes in refractive index visible. Here, schlieren imaging was used to visualize helium flow from a plasma-based ADI-MS source into a mass spectrometer while ion signals were recorded. Optimal sample positions for melting-point capillary and transmission-mode (stainless steel mesh) introduction were found to be near (within 1 mm of) the mass spectrometer inlet. Additionally, the orientation of the sampled surface plays a significant role. More efficient mass transport resulted for analyte deposits directly facing the MS inlet. Different surfaces (glass slide and rough surface) were also examined; for both it was found that the optimal position is immediately beneath the MS inlet. PMID:24658804

  9. Measurement and visualization of mass transport for the flowing atmospheric pressure afterglow (FAPA) ambient mass-spectrometry source.

    PubMed

    Pfeuffer, Kevin P; Ray, Steven J; Hieftje, Gary M

    2014-05-01

    Ambient desorption/ionization mass spectrometry (ADI-MS) has developed into an important analytical field over the last 9 years. The ability to analyze samples under ambient conditions while retaining the sensitivity and specificity of mass spectrometry has led to numerous applications and a corresponding jump in the popularity of this field. Despite the great potential of ADI-MS, problems remain in the areas of ion identification and quantification. Difficulties with ion identification can be solved through modified instrumentation, including accurate-mass or MS/MS capabilities for analyte identification. More difficult problems include quantification because of the ambient nature of the sampling process. To characterize and improve sample volatilization, ionization, and introduction into the mass spectrometer interface, a method of visualizing mass transport into the mass spectrometer is needed. Schlieren imaging is a well-established technique that renders small changes in refractive index visible. Here, schlieren imaging was used to visualize helium flow from a plasma-based ADI-MS source into a mass spectrometer while ion signals were recorded. Optimal sample positions for melting-point capillary and transmission-mode (stainless steel mesh) introduction were found to be near (within 1 mm of) the mass spectrometer inlet. Additionally, the orientation of the sampled surface plays a significant role. More efficient mass transport resulted for analyte deposits directly facing the MS inlet. Different surfaces (glass slide and rough surface) were also examined; for both it was found that the optimal position is immediately beneath the MS inlet.

  10. Measurement and Visualization of Mass Transport for the Flowing Atmospheric Pressure Afterglow (FAPA) Ambient Mass-Spectrometry Source

    NASA Astrophysics Data System (ADS)

    Pfeuffer, Kevin P.; Ray, Steven J.; Hieftje, Gary M.

    2014-05-01

    Ambient desorption/ionization mass spectrometry (ADI-MS) has developed into an important analytical field over the last 9 years. The ability to analyze samples under ambient conditions while retaining the sensitivity and specificity of mass spectrometry has led to numerous applications and a corresponding jump in the popularity of this field. Despite the great potential of ADI-MS, problems remain in the areas of ion identification and quantification. Difficulties with ion identification can be solved through modified instrumentation, including accurate-mass or MS/MS capabilities for analyte identification. More difficult problems include quantification because of the ambient nature of the sampling process. To characterize and improve sample volatilization, ionization, and introduction into the mass spectrometer interface, a method of visualizing mass transport into the mass spectrometer is needed. Schlieren imaging is a well-established technique that renders small changes in refractive index visible. Here, schlieren imaging was used to visualize helium flow from a plasma-based ADI-MS source into a mass spectrometer while ion signals were recorded. Optimal sample positions for melting-point capillary and transmission-mode (stainless steel mesh) introduction were found to be near (within 1 mm of) the mass spectrometer inlet. Additionally, the orientation of the sampled surface plays a significant role. More efficient mass transport resulted for analyte deposits directly facing the MS inlet. Different surfaces (glass slide and rough surface) were also examined; for both it was found that the optimal position is immediately beneath the MS inlet.

  11. Introducing a checking technician allows pharmacists to spend more time on patient-focused activities.

    PubMed

    Napier, Patti; Norris, Pauline; Braund, Rhiannon

    2018-04-01

    Internationally there is an increasing focus on the clinical and cognitive services that pharmacists can provide. Lack of time has been identified as a barrier to pharmacists increasing their clinical activities. Within the pharmacy workplace there are many tasks that can only be performed by a pharmacist. The final accuracy check of a dispensed prescription is currently the sole responsibility of pharmacists in New Zealand. This takes up a significant amount of time during a pharmacist's work day. The introduction of a checking technician role has been suggested to allow pharmacists more time to do more patient focused work. To investigate the amount of time pharmacy staff spend on specific activities and to establish whether the introduction of a checking technician into twelve pilot sites increased the amount of time that the pharmacists could spend on patient focused activities. This study utilised a self-reported work sampling technique in twelve pilot sites, selected from both the hospital and community settings. Work sampling using an electronic device was conducted at two time-points (before the implementation of a Pharmacy Accuracy Checking Technician (PACT) role and when the PACT was in place). Data was collected at 10 min intervals for the period of five days, a working week. Tasks were grouped into patient focused, dispensing and personal activities. The introduction of the PACT into the pilot sites saw a mean increase of 19% in pharmacists' patient focused activities and a mean 20% decrease in dispensing activities. The introduction of a checking technician role into New Zealand pharmacies demonstrated the potential to provide pharmacists with more time to spend on patient focused activities. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Hyphenated analytical techniques for materials characterisation

    NASA Astrophysics Data System (ADS)

    Armstrong, Gordon; Kailas, Lekshmi

    2017-09-01

    This topical review will provide a survey of the current state of the art in ‘hyphenated’ techniques for characterisation of bulk materials, surface, and interfaces, whereby two or more analytical methods investigating different properties are applied simultaneously to the same sample to better characterise the sample than can be achieved by conducting separate analyses in series using different instruments. It is intended for final year undergraduates and recent graduates, who may have some background knowledge of standard analytical techniques, but are not familiar with ‘hyphenated’ techniques or hybrid instrumentation. The review will begin by defining ‘complementary’, ‘hybrid’ and ‘hyphenated’ techniques, as there is not a broad consensus among analytical scientists as to what each term means. The motivating factors driving increased development of hyphenated analytical methods will also be discussed. This introduction will conclude with a brief discussion of gas chromatography-mass spectroscopy and energy dispersive x-ray analysis in electron microscopy as two examples, in the context that combining complementary techniques for chemical analysis were among the earliest examples of hyphenated characterisation methods. The emphasis of the main review will be on techniques which are sufficiently well-established that the instrumentation is commercially available, to examine physical properties including physical, mechanical, electrical and thermal, in addition to variations in composition, rather than methods solely to identify and quantify chemical species. Therefore, the proposed topical review will address three broad categories of techniques that the reader may expect to encounter in a well-equipped materials characterisation laboratory: microscopy based techniques, scanning probe-based techniques, and thermal analysis based techniques. Examples drawn from recent literature, and a concluding case study, will be used to explain the practical issues that arise in combining different techniques. We will consider how the complementary and varied information obtained by combining these techniques may be interpreted together to better understand the sample in greater detail than that was possible before, and also how combining different techniques can simplify sample preparation and ensure reliable comparisons are made between multiple analyses on the same samples—a topic of particular importance as nanoscale technologies become more prevalent in applied and industrial research and development (R&D). The review will conclude with a brief outline of the emerging state of the art in the research laboratory, and a suggested approach to using hyphenated techniques, whether in the teaching, quality control or R&D laboratory.

  13. Sample introduction apparatus for a flow cytometer

    DOEpatents

    Van den Engh, Ger

    1998-01-01

    A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning HPLC tubing and fittings may be used in a manner which facilitates removable of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it.

  14. Sample introduction system for a flow cytometer

    DOEpatents

    Van den Engh, Ger

    1997-01-01

    A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning, HPLC tubing and fittings may be used in a manner which facilitates removing of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it.

  15. Sample introduction apparatus for a flow cytometer

    DOEpatents

    Van den Engh, G.

    1998-03-10

    A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning HPLC tubing and fittings may be used in a manner which facilitates removable of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it. 3 figs.

  16. Sample introduction system for a flow cytometer

    DOEpatents

    Engh, G. van den

    1997-02-11

    A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning, HPLC tubing and fittings may be used in a manner which facilitates removing of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it. 3 figs.

  17. Hall effect analysis in irradiated silicon samples with different resistivities

    NASA Astrophysics Data System (ADS)

    Borchi, E.; Bruzzi, M.; Dezillie, B.; Lazanu, S.; Li, Z.; Pirollo, S.

    1999-08-01

    The changes induced by neutron irradiation in n- and p-type silicon samples with starting resistivities from 10 /spl Omega/-cm up to 30 k/spl Omega/-cm, grown using different techniques, as float-zone (FZ), Czochralski (CZ) and epitaxial, have been analyzed by Van der Pauw and Hall effect measurements. Increasing the fluence, each set of samples evolves toward a quasi-intrinsic p-type material. This behavior has been explained in the frame of a two-level model, that considers the introduction during irradiation of mainly two defects. A deep acceptor and a deep donor, probably related to the divacancy and to the C/sub i/O/sub i/ complex, are placed in the upper and lower half of the forbidden gap, respectively. This simple model explains quantitatively the data on resistivity and Hall coefficient of each set of samples up to the fluence of /spl ap/10/sup 14/ n/cm/sup 2/.

  18. Lowering detection limits for 1,2,3-trichloropropane in water using solid phase extraction coupled to purge and trap sample introduction in an isotope dilution GC-MS method.

    PubMed

    Liao, Wenta; Ghabour, Miriam; Draper, William M; Chandrasena, Esala

    2016-09-01

    Purge and trap sample introduction (PTI) has been the premier sampling and preconcentration technique for gas chromatographic determination of volatile organic compounds (VOCs) in drinking water for almost 50 years. PTI affords sub parts-per-billion (ppb) detection limits for purgeable VOCs including fixed gases and higher boiling hydrocarbons and halocarbons. In this study the coupling of solid phase extraction (SPE) to PTI was investigated as a means to substantially increase enrichment and lower detection limits for the emerging contaminant, 1,2,3-trichloropropane (TCP). Water samples (500 mL) were dechlorinated, preserved with a biocide, and spiked with the isotope labeled internal standard, d5-TCP. The entire 500 mL sample was extracted with activated carbon or carbon molecular sieve SPE cartridges, and then eluted with dichloromethane -- excess solvent was removed in a nitrogen evaporator and diethylene glycol "keeper" remaining was dispersed in 5 mL of water for PTI GC-MS analysis. The experimental Method Detection Limit (MDL) for TCP was 0.11 ng/L (ppt) and accuracy was 95-103% in sub-ppt determinations. Groundwater samples including impaired California sources and treated water (n = 21) were analyzed with results ranging from below the method reporting limit (0.30 ng/L) to > 250 ng/L. Coupling of SPE with PTI may provide similar reductions in detection limits for other VOCs with appropriate physical-chemical properties. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. The Three-Fingers Technique: Does It Reduce Test Anxiety?

    ERIC Educational Resources Information Center

    Maycock, George

    The utility of brief exposure to a mental focusing aid, the Three-Fingers Technique (TFT), in reducing test anxiety was studied for 15 college students. One week before their final examination, the students were given a 15-minute classroom introduction to the TFT, part of the Silva Mental Training Method (1983). After the introduction to this…

  20. Method optimization and quality assurance in speciation analysis using high performance liquid chromatography with detection by inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Larsen, Erik H.

    1998-02-01

    Achievement of optimum selectivity, sensitivity and robustness in speciation analysis using high performance liquid chromatography (HPLC) with inductively coupled mass spectrometry (ICP-MS) detection requires that each instrumental component is selected and optimized with a view to the ideal operating characteristics of the entire hyphenated system. An isocratic HPLC system, which employs an aqueous mobile phase with organic buffer constituents, is well suited for introduction into the ICP-MS because of the stability of the detector response and high degree of analyte sensitivity attained. Anion and cation exchange HPLC systems, which meet these requirements, were used for the seperation of selenium and arsenic species in crude extracts of biological samples. Furthermore, the signal-to-noise ratios obtained for these incompletely ionized elements in the argon ICP were further enhanced by a factor of four by continously introducing carbon as methanol via the mobile phase into the ICP. Sources of error in the HPLC system (column overload), in the sample introduction system (memory by organic solvents) and in the ICP-MS (spectroscopic interferences) and their prevention are also discussed. The optimized anion and cation exchange HPLC-ICP-MS systems were used for arsenic speciation in contaminated ground water and in an in-house shrimp reference sample. For the purpose of verification, HPLC coupled with tandem mass spectrometry with electrospray ionization was additionally used for arsenic speciation in the shrimp sample. With this analytical technique the HPLC retention time in combination with mass analysis of the molecular ions and their collision-induced fragments provide almost conclusive evidence of the identity of the analyte species. The speciation methods are validated by establishing a mass balance of the analytes in each fraction of the extraction procedure, by recovery of spikes and by employing and comparing independent techniques. The urgent need for reference materials certified for elemental species is stressed.

  1. Rapid identification of bacteria with miniaturized pyrolysis/GC analysis

    NASA Astrophysics Data System (ADS)

    Morgan, Catherine H.; Mowry, Curtis; Manginell, Ronald P.; Frye-Mason, Gregory C.; Kottenstette, Richard J.; Lewis, Patrick

    2001-02-01

    Identification of bacteria and other biological moieties finds a broad range of applications in the environmental, biomedical, agricultural, industrial, and military arenas. Linking these applications are biological markers such as fatty acids, whose mass spectral profiles can be used to characterize biological samples and to distinguish bacteria at the gram-type, genera, and even species level. Common methods of sample analysis require sample preparation that is both lengthy and labor intensive, especially for whole cell bacteria. The background technique relied on here utilizes chemical derivatization of fatty acids to the more volatile fatty acid methyl esters (FAMEs), which can be separated on a gas chromatograph column or input directly into a mass spectrometer. More recent publications demonstrate improved sample preparation time with in situ derivatization of whole bacterial samples using pyrolysis at the inlet; although much faster than traditional techniques, these systems still rely on bench-top analytical equipment and individual sample preparation. Development of a miniaturized pyrolysis/GC instrument by this group is intended to realize the benefits of FAME identification of bacteria and other biological samples while further facilitating sample handling and instrument portability. The technologies being fabricated and tested have the potential of achieving pyrolysis and FAME separation on a very small scale, with rapid detection time (1-10 min from introduction to result), and with a modular sample inlet. Performance results and sensor characterization will be presented for the first phase of instrument development, encompassing the microfabricated pyrolysis and gas chromatograph elements.

  2. Surveillance of low pathogenic novel H7N9 avian influenza in commercial poultry barns: detection of outbreaks and estimation of virus introduction time.

    PubMed

    Pinsent, Amy; Blake, Isobel M; White, Michael T; Riley, Steven

    2014-08-01

    Both high and low pathogenic subtype A avian influenza remain ongoing threats to the commercial poultry industry globally. The emergence of a novel low pathogenic H7N9 lineage in China presents itself as a new concern to both human and animal health and may necessitate additional surveillance in commercial poultry operations in affected regions. Sampling data was simulated using a mechanistic model of H7N9 influenza transmission within commercial poultry barns together with a stochastic observation process. Parameters were estimated using maximum likelihood. We assessed the probability of detecting an outbreak at time of slaughter using both real-time polymerase chain reaction (rt-PCR) and a hemagglutinin inhibition assay (HI assay) before considering more intense sampling prior to slaughter. The day of virus introduction and R0 were estimated jointly from weekly flock sampling data. For scenarios where R0 was known, we estimated the day of virus introduction into a barn under different sampling frequencies. If birds were tested at time of slaughter, there was a higher probability of detecting evidence of an outbreak using an HI assay compared to rt-PCR, except when the virus was introduced <2 weeks before time of slaughter. Prior to the initial detection of infection N sample = 50 (1%) of birds were sampled on a weekly basis once, but after infection was detected, N sample = 2000 birds (40%) were sampled to estimate both parameters. We accurately estimated the day of virus introduction in isolation with weekly and 2-weekly sampling. A strong sampling effort would be required to infer both the day of virus introduction and R0. Such a sampling effort would not be required to estimate the day of virus introduction alone once R0 was known, and sampling N sample = 50 of birds in the flock on a weekly or 2 weekly basis would be sufficient.

  3. Predicting factors for malaria re-introduction: an applied model in an elimination setting to prevent malaria outbreaks.

    PubMed

    Ranjbar, Mansour; Shoghli, Alireza; Kolifarhood, Goodarz; Tabatabaei, Seyed Mehdi; Amlashi, Morteza; Mohammadi, Mahdi

    2016-03-02

    Malaria re-introduction is a challenge in elimination settings. To prevent re-introduction, receptivity, vulnerability, and health system capacity of foci should be monitored using appropriate tools. This study aimed to design an applicable model to monitor predicting factors of re-introduction of malaria in highly prone areas. This exploratory, descriptive study was conducted in a pre-elimination setting with a high-risk of malaria transmission re-introduction. By using nominal group technique and literature review, a list of predicting indicators for malaria re-introduction and outbreak was defined. Accordingly, a checklist was developed and completed in the field for foci affected by re-introduction and for cleared-up foci as a control group, for a period of 12 weeks before re-introduction and for the same period in the previous year. Using field data and analytic hierarchical process (AHP), each variable and its sub-categories were weighted, and by calculating geometric means for each sub-category, score of corresponding cells of interaction matrices, lower and upper threshold of different risks strata, including low and mild risk of re-introduction and moderate and high risk of malaria outbreaks, were determined. The developed predictive model was calibrated through resampling with different sets of explanatory variables using R software. Sensitivity and specificity of the model were calculated based on new samples. Twenty explanatory predictive variables of malaria re-introduction were identified and a predictive model was developed. Unpermitted immigrants from endemic neighbouring countries were determined as a pivotal factor (AHP score: 0.181). Moreover, quality of population movement (0.114), following malaria transmission season (0.088), average daily minimum temperature in the previous 8 weeks (0.062), an outdoor resting shelter for vectors (0.045), and rainfall (0.042) were determined. Positive and negative predictive values of the model were 81.8 and 100 %, respectively. This study introduced a new, simple, yet reliable model to forecast malaria re-introduction and outbreaks eight weeks in advance in pre-elimination and elimination settings. The model incorporates comprehensive deterministic factors that can easily be measured in the field, thereby facilitating preventive measures.

  4. Glyphosate analysis using sensors and electromigration separation techniques as alternatives to gas or liquid chromatography.

    PubMed

    Gauglitz, Günter; Wimmer, Benedikt; Melzer, Tanja; Huhn, Carolin

    2018-01-01

    Since its introduction in 1974, the herbicide glyphosate has experienced a tremendous increase in use, with about one million tons used annually today. This review focuses on sensors and electromigration separation techniques as alternatives to chromatographic methods for the analysis of glyphosate and its metabolite aminomethyl phosphonic acid. Even with the large number of studies published, glyphosate analysis remains challenging. With its polar and depending on pH even ionic functional groups lacking a chromophore, it is difficult to analyze with chromatographic techniques. Its analysis is mostly achieved after derivatization. Its purification from food and environmental samples inevitably results incoextraction of ionic matrix components, with a further impact on analysis derivatization. Its purification from food and environmental samples inevitably results in coextraction of ionic matrix components, with a further impact on analysis and also derivatization reactions. Its ability to form chelates with metal cations is another obstacle for precise quantification. Lastly, the low limits of detection required by legislation have to be met. These challenges preclude glyphosate from being analyzed together with many other pesticides in common multiresidue (chromatographic) methods. For better monitoring of glyphosate in environmental and food samples, further fast and robust methods are required. In this review, analytical methods are summarized and discussed from the perspective of biosensors and various formats of electromigration separation techniques, including modes such as capillary electrophoresis and micellar electrokinetic chromatography, combined with various detection techniques. These methods are critically discussed with regard to matrix tolerance, limits of detection reached, and selectivity.

  5. Effect of copper on the recombination activity of extended defects in silicon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feklisova, O. V., E-mail: feklisov@iptm.ru; Yakimov, E. B.

    2015-06-15

    The effect of copper atoms introduced by high-temperature diffusion on the recombination properties of dislocations and dislocation trails in p-type single-crystal silicon is studied by the electron-beam-induced current technique. It is shown that, in contrast to dislocations, dislocation trails exhibit an increase in recombination activity after the introduction of copper. Bright contrast appearance in the vicinity of dislocation trails is detected after the diffusion of copper and quenching of the samples. The contrast depends on the defect density in these trails.

  6. Electron density of Rhizophora spp. wood using Compton scattering technique at 15.77, 17.48 and 22.16 keV XRF energies

    NASA Astrophysics Data System (ADS)

    Shakhreet, B. Z.; Bauk, S.; Shukri, A.

    2015-02-01

    Compton (incoherently) scattered photons which are directly proportional to the electron density of the scatterer, have been employed in characterizing Rhizophora spp. as breast tissue equivalent. X-ray fluorescent scattered incoherently from Rhizophora spp. sample was measured using Si-PIN detector and three XRF energy values 15.77, 17.48 and 22.16 keV. This study is aimed at providing electron density information in support of the introduction of new tissue substitute materials for mammography phantoms.

  7. Recent trends in atomic fluorescence spectrometry towards miniaturized instrumentation-A review.

    PubMed

    Zou, Zhirong; Deng, Yujia; Hu, Jing; Jiang, Xiaoming; Hou, Xiandeng

    2018-08-17

    Atomic fluorescence spectrometry (AFS), as one of the common atomic spectrometric techniques with high sensitivity, simple instrumentation, and low acquisition and running cost, has been widely used in various fields for trace elemental analysis, notably the determination of hydride-forming elements by hydride generation atomic fluorescence spectrometry (HG-AFS). In recent years, the soaring demand of field analysis has significantly promoted the miniaturization of analytical atomic spectrometers or at least instrumental components. Various techniques have also been developed to approach the goal of portable/miniaturized AFS instrumentation for field analysis. In this review, potentially portable/miniaturized AFS techniques, primarily involving advanced instrumental components and whole instrumentation with references since 2000, are summarized and discussed. The discussion mainly includes five aspects: radiation source, atomizer, detector, sample introduction, and miniaturized atomic fluorescence spectrometer/system. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Interfaces and thin films as seen by bound electromagnetic waves.

    PubMed

    Knoll, W

    1998-01-01

    This contribution summarizes the use of plasmon surface polaritons and guided optical waves for the characterization of interfaces and thin organic films. After a short introduction to the theoretical background of evanescent wave optics, examples are given that show how this interfacial "light" can be employed to monitor thin coatings at a solid/air or solid/liquid interface. Examples are given for a very sensitive thickness determination of samples ranging from self-assembled monolayers, to multilayer assemblies prepared by the Langmuir/Blodgett/Kuhn technique or by the alternate polyelectrolyte deposition. These are complemented by the demonstration of the potential of the technique to also monitor time-dependent processes in a kinetic mode. Here, we put an emphasis on the combination set-up of surface plasmon optics with electrochemical techniques, allowing for the on-line characterization of various surface functionalization strategies, e.g. for (bio-) sensor purposes.

  9. Accelerometer Data Analysis and Presentation Techniques

    NASA Technical Reports Server (NTRS)

    Rogers, Melissa J. B.; Hrovat, Kenneth; McPherson, Kevin; Moskowitz, Milton E.; Reckart, Timothy

    1997-01-01

    The NASA Lewis Research Center's Principal Investigator Microgravity Services project analyzes Orbital Acceleration Research Experiment and Space Acceleration Measurement System data for principal investigators of microgravity experiments. Principal investigators need a thorough understanding of data analysis techniques so that they can request appropriate analyses to best interpret accelerometer data. Accelerometer data sampling and filtering is introduced along with the related topics of resolution and aliasing. Specific information about the Orbital Acceleration Research Experiment and Space Acceleration Measurement System data sampling and filtering is given. Time domain data analysis techniques are discussed and example environment interpretations are made using plots of acceleration versus time, interval average acceleration versus time, interval root-mean-square acceleration versus time, trimmean acceleration versus time, quasi-steady three dimensional histograms, and prediction of quasi-steady levels at different locations. An introduction to Fourier transform theory and windowing is provided along with specific analysis techniques and data interpretations. The frequency domain analyses discussed are power spectral density versus frequency, cumulative root-mean-square acceleration versus frequency, root-mean-square acceleration versus frequency, one-third octave band root-mean-square acceleration versus frequency, and power spectral density versus frequency versus time (spectrogram). Instructions for accessing NASA Lewis Research Center accelerometer data and related information using the internet are provided.

  10. Development of a Cross-Disciplinary Investigative Model for the Introduction of Microarray Techniques at Non-R1 Undergraduate Institutions

    ERIC Educational Resources Information Center

    Walker, David E.; Lutz, Gary P.; Alvarez, Consuelo J.

    2008-01-01

    Integrating advanced biological techniques into instruction at non-R1 institutions can prove to be a challenge. Here, we report the creation of a model for the introduction of gene expression microarray technology into a research laboratory. A student assessment tool was used to evaluate: (1) technical skill development; (2) cross-disciplinary…

  11. Nonuniform sampling and non-Fourier signal processing methods in multidimensional NMR.

    PubMed

    Mobli, Mehdi; Hoch, Jeffrey C

    2014-11-01

    Beginning with the introduction of Fourier Transform NMR by Ernst and Anderson in 1966, time domain measurement of the impulse response (the free induction decay, FID) consisted of sampling the signal at a series of discrete intervals. For compatibility with the discrete Fourier transform (DFT), the intervals are kept uniform, and the Nyquist theorem dictates the largest value of the interval sufficient to avoid aliasing. With the proposal by Jeener of parametric sampling along an indirect time dimension, extension to multidimensional experiments employed the same sampling techniques used in one dimension, similarly subject to the Nyquist condition and suitable for processing via the discrete Fourier transform. The challenges of obtaining high-resolution spectral estimates from short data records using the DFT were already well understood, however. Despite techniques such as linear prediction extrapolation, the achievable resolution in the indirect dimensions is limited by practical constraints on measuring time. The advent of non-Fourier methods of spectrum analysis capable of processing nonuniformly sampled data has led to an explosion in the development of novel sampling strategies that avoid the limits on resolution and measurement time imposed by uniform sampling. The first part of this review discusses the many approaches to data sampling in multidimensional NMR, the second part highlights commonly used methods for signal processing of such data, and the review concludes with a discussion of other approaches to speeding up data acquisition in NMR. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. In situ ionic liquid dispersive liquid-liquid microextraction coupled to gas chromatography-mass spectrometry for the determination of organophosphorus pesticides.

    PubMed

    Cacho, J I; Campillo, N; Viñas, P; Hernández-Córdoba, M

    2018-07-20

    Nine organophosphorus pesticides (OPPs) were determined in environmental waters from different origins using in situ ionic liquid dispersive liquid microextraction (IL-DLLME). This preconcentration technique was coupled to gas chromatography-mass spectrometry (GC-MS) using microvial insert thermal desorption, an approach that uses a thermal desorption injector as sample introduction system. The parameters affecting both the microextraction and sample injection steps were optimized. The proposed method showed good precision, with RSD values ranging from 4.1 to 9.7%, accuracy with recoveries in the 85-118% range, and sensitivity with DLs ranging from 5 to 16 ng L -1 . Copyright © 2017 Elsevier B.V. All rights reserved.

  13. A Versatile Integrated Ambient Ionization Source Platform.

    PubMed

    Ai, Wanpeng; Nie, Honggang; Song, Shiyao; Liu, Xiaoyun; Bai, Yu; Liu, Huwei

    2018-04-30

    The pursuit of high-throughput sample analysis from complex matrix demands development of multiple ionization techniques with complementary specialties. A versatile integrated ambient ionization source (iAmIS) platform is proposed in this work, based on the idea of integrating multiple functions, enhancing the efficiency of current ionization techniques, extending the applications, and decreasing the cost of the instrument. The design of the iAmIS platform combines flowing atmospheric pressure afterglow (FAPA) source/direct analysis in real time (DART), dielectric barrier discharge ionization (DBDI)/low-temperature plasma (LTP), desorption electrospray ionization (DESI), and laser desorption (LD) technique. All individual and combined ionization modes can be easily attained by modulating parameters. In particular, the FAPA/DART&DESI mode can realize the detection of polar and nonpolar compounds at the same time with two different ionization mechanisms: proton transfer and charge transfer. The introduction of LD contributes to the mass spectrometry imaging and the surface-assisted laser desorption (SALDI) under ambient condition. Compared with other individual or multi-mode ion source, the iAmIS platform provides the flexibility of choosing different ionization modes, broadens the scope of the analyte detection, and facilitates the analysis of complex samples. Graphical abstract ᅟ.

  14. A Versatile Integrated Ambient Ionization Source Platform

    NASA Astrophysics Data System (ADS)

    Ai, Wanpeng; Nie, Honggang; Song, Shiyao; Liu, Xiaoyun; Bai, Yu; Liu, Huwei

    2018-04-01

    The pursuit of high-throughput sample analysis from complex matrix demands development of multiple ionization techniques with complementary specialties. A versatile integrated ambient ionization source (iAmIS) platform is proposed in this work, based on the idea of integrating multiple functions, enhancing the efficiency of current ionization techniques, extending the applications, and decreasing the cost of the instrument. The design of the iAmIS platform combines flowing atmospheric pressure afterglow (FAPA) source/direct analysis in real time (DART), dielectric barrier discharge ionization (DBDI)/low-temperature plasma (LTP), desorption electrospray ionization (DESI), and laser desorption (LD) technique. All individual and combined ionization modes can be easily attained by modulating parameters. In particular, the FAPA/DART&DESI mode can realize the detection of polar and nonpolar compounds at the same time with two different ionization mechanisms: proton transfer and charge transfer. The introduction of LD contributes to the mass spectrometry imaging and the surface-assisted laser desorption (SALDI) under ambient condition. Compared with other individual or multi-mode ion source, the iAmIS platform provides the flexibility of choosing different ionization modes, broadens the scope of the analyte detection, and facilitates the analysis of complex samples. [Figure not available: see fulltext.

  15. Western pond turtle: Biology, sampling techniques, inventory and monitoring, conservation, and management: Northwest Fauna No. 7

    USGS Publications Warehouse

    Bury, R.B.; Welsh, Hartwell H.; Germano, David J.; Ashton, Donald T.

    2012-01-01

    One of only two native, freshwater turtle species in the western United States, western pond turtles are declining in portions of their original range. Declines are mostly due to habitat loss, introduction of non-native species, pollution, and lack of connectivity among populations. USGS zoologist R. Bruce Bury and colleagues from the U.S. Forest Service, California State University, and other agencies compiled and edited a new review and field manual of this charismatic species. Objectives were to determine its current distribution and abundance, summarize and evaluate population features, review techniques to detect population and habitat changes, and improve monitoring for long-term trends. Methods described in the manual should improve consistency, efficiency, and accuracy of survey data, resulting in improved management and conservation efforts.

  16. Gallery of melt textures developed in Westerly Granite during high-pressure triaxial friction experiments

    USGS Publications Warehouse

    Moore, Diane E.; Lockner, David A.; Kilgore, Brian D.; Beeler, Nicholas M.

    2016-09-23

    IntroductionMelting occurred during stick-slip faulting of granite blocks sheared at room-dry, room-temperature conditions in a triaxial apparatus at 200–400 megapascals (MPa) confining pressure. Petrographic examinations of melt textures focused largely on the 400-MPa run products. This report presents an overview of the petrographic data collected on those samples, followed by brief descriptions of annotated versions of all the images.Scanning electron microscope (SEM) images of the starting materials and the three examined 400-MPa samples are presented in this report. Secondary-electron (SE) and backscattered-electron (BSE) imaging techniques were used on different samples. The SE images look down on the sawcut surfaces, yielding topographic and three-dimensional textural information. The BSE imaging was done on samples cut to provide cross-sectional views of the glass-filled shear band (or zone) that developed along the sawcut. Brightness in the BSE images increases with increasing mean atomic number of the material. Additional chemical information about the quenched melt and adjoining minerals was obtained using the energy dispersive system of the SEM during BSE examinations. However, the very narrow shear-band thicknesses and common occurrence of very fine lamellar compositional layering limited the usefulness of this technique for estimating melt chemistry.

  17. An environmentally-friendly, highly efficient, gas pressure-assisted sample introduction system for ICP-MS and its application to detection of cadmium and lead in human plasma.

    PubMed

    Cao, Yupin; Deng, Biyang; Yan, Lizhen; Huang, Hongli

    2017-05-15

    An environmentally friendly and highly efficient gas pressure-assisted sample introduction system (GPASIS) was developed for inductively-coupled plasma mass spectrometry. A GPASIS consisting of a gas-pressure control device, a customized nebulizer, and a custom-made spray chamber was fabricated. The advantages of this GPASIS derive from its high nebulization efficiencies, small sample volume requirements, low memory effects, good precision, and zero waste emission. A GPASIS can continuously, and stably, nebulize 10% NaCl solution for more than an hour without clogging. Sensitivity, detection limits, precision, long-term stability, double charge and oxide ion levels, nebulization efficiencies, and matrix effects of the sample introduction system were evaluated. Experimental results indicated that the performance of this GPASIS, was equivalent to, or better than, those obtained by conventional sample introduction systems. This GPASIS was successfully used to determine Cd and Pb by ICP-MS in human plasma. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Determination of extremely low (236)U/(238)U isotope ratios in environmental samples by sector-field inductively coupled plasma mass spectrometry using high-efficiency sample introduction.

    PubMed

    Boulyga, Sergei F; Heumann, Klaus G

    2006-01-01

    A method by inductively coupled plasma mass spectrometry (ICP-MS) was developed which allows the measurement of (236)U at concentration ranges down to 3 x 10(-14)g g(-1) and extremely low (236)U/(238)U isotope ratios in soil samples of 10(-7). By using the high-efficiency solution introduction system APEX in connection with a sector-field ICP-MS a sensitivity of more than 5,000 counts fg(-1) uranium was achieved. The use of an aerosol desolvating unit reduced the formation rate of uranium hydride ions UH(+)/U(+) down to a level of 10(-6). An abundance sensitivity of 3 x 10(-7) was observed for (236)U/(238)U isotope ratio measurements at mass resolution 4000. The detection limit for (236)U and the lowest detectable (236)U/(238)U isotope ratio were improved by more than two orders of magnitude compared with corresponding values by alpha spectrometry. Determination of uranium in soil samples collected in the vicinity of Chernobyl nuclear power plant (NPP) resulted in that the (236)U/(238)U isotope ratio is a much more sensitive and accurate marker for environmental contamination by spent uranium in comparison to the (235)U/(238)U isotope ratio. The ICP-MS technique allowed for the first time detection of irradiated uranium in soil samples even at distances more than 200 km to the north of Chernobyl NPP (Mogilev region). The concentration of (236)U in the upper 0-10 cm soil layers varied from 2 x 10(-9)g g(-1) within radioactive spots close to the Chernobyl NPP to 3 x 10(-13)g g(-1) on a sampling site located by >200 km from Chernobyl.

  19. Methods for determination of inorganic substances in water and fluvial sediments

    USGS Publications Warehouse

    Fishman, Marvin J.; Friedman, Linda C.

    1989-01-01

    Chapter Al of the laboratory manual contains methods used by the U.S. Geological Survey to analyze samples of water, suspended sediments, and bottom material for their content of inorganic constituents. Included are methods for determining the concentration of dissolved constituents in water, the total recoverable and total of constituents in water-suspended sediment samples, and the recoverable and total concentrations of constituents in samples of bottom material. The introduction to the manual includes essential definitions and a brief discussion of the use of significant figures in calculating and reporting analytical results. Quality control in the water-analysis laboratory is discussed, including the accuracy and precision of analyses, the use of standard-reference water samples, and the operation of an effective quality-assurance program. Methods for sample preparation and pretreatment are given also. A brief discussion of the principles of the analytical techniques involved and their particular application to water and sediment analysis is presented. The analytical methods of these techniques are arranged alphabetically by constituent. For each method, the general topics covered are the application, the principle of the method, the interferences, the apparatus and reagents required, a detailed description of the analytical procedure, reporting results, units and significant figures, and analytical precision data, when available. More than 126 methods are given for the determination of 70 inorganic constituents and physical properties of water, suspended sediment, and bottom material.

  20. Methods for determination of inorganic substances in water and fluvial sediments

    USGS Publications Warehouse

    Fishman, Marvin J.; Friedman, Linda C.

    1985-01-01

    Chapter Al of the laboratory manual contains methods used by the Geological Survey to analyze samples of water, suspended sediments, and bottom material for their content of inorganic constituents. Included are methods for determining the concentration of dissolved constituents in water, total recoverable and total of constituents in water-suspended sediment samples, and recoverable and total concentrations of constituents in samples of bottom material. Essential definitions are included in the introduction to the manual, along with a brief discussion of the use of significant figures in calculating and reporting analytical results. Quality control in the water-analysis laboratory is discussed, including accuracy and precision of analyses, the use of standard reference water samples, and the operation of an effective quality assurance program. Methods for sample preparation and pretreatment are given also.A brief discussion of the principles of the analytical techniques involved and their particular application to water and sediment analysis is presented. The analytical methods involving these techniques are arranged alphabetically according to constituent. For each method given, the general topics covered are application, principle of the method, interferences, apparatus and reagents required, a detailed description of the analytical procedure, reporting results, units and significant figures, and analytical precision data, when available. More than 125 methods are given for the determination of 70 different inorganic constituents and physical properties of water, suspended sediment, and bottom material.

  1. Atomic spectrometry update - atomic mass spectrometry.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bacon, J.; Crain, J. S.; McMahon, A. W.

    The MS and XRF updates have been published together since their introduction in 1988. In the last few years, however, the two sections have been prepared independently of each other and it therefore seemed appropriate to publish the two sections separately. With effect from this issue, the MS Update will appear in the October issue of JAAS and the XRF Update in the November issue. The format used for the MS section is broadly similar to that used last year, with some additional sub-headings. This Update is intended to cover all atomic and stable isotopic MS techniques, but not thosemore » used in studies of fundamental nuclear physics and exotic nuclei far from stability. Also excluded are those reports in which MS is used as a tool in the study of molecular processes and of gaseous components. the review is based on critical selection of developments in instrumentation and methodology, notable for their innovation, originality or achievement of significant advances, and is not intended to be comprehensive in its coverage. Conference papers are only included if they contain enough information to show they meet these criteria, and our policy in general remains one of waiting for a development to appear in a full paper before inclusion in the review. a similar policy applies to foreign language papers unlikely to reach a wide audience. Routine applications of atomic MS are not included in this Update and the reader is referred to the Updates on Industrial Analysis: Metals, Chemicals and Advanced Materials (96/416), Environmental Analysis (96/1444) and Clinical and Biological Materials, Food and Beverages (96/2479). Also excluded are those applications, even if not routine, which use atomic spectroscopy as a tool for the study of a non-atomic property, for example, the use of stable isotope labeling of carbon or nitrogen in biomolecules in metabolic studies. There have been few general reviews on atomic MS of note in the period covered by this update. That of Colodner et al.(95/3890) gave a general review of ion sources, in particular GDMS, ICP-MS, SIMS and TIMS, and that of Blades (95/2568 and 95/3077) was a very general overview of some of the techniques covered in this Update. The review of the literature in the period covered by this Update reveals strong advances in all areas, with a continuing push to achieve better analyses on smaller samples and in less time. Most advances generally require more sophisticated instrumentation, improved sample preparation methods or new methods of sample introduction. This is typified by advances in ICP-MS, which see considerable emphasis on sample introduction techniques and a move towards magnetic sector instruments. Most applications of ICP-MS are now highly routine. There is still, however, a desire to achieve affordable analysis with simplified and cost-effective instruments, as illustrated by the development of mobile, in-situ isotope MS for environmental studies.« less

  2. Functional Imaging and Related Techniques: An Introduction for Rehabilitation Researchers

    PubMed Central

    Crosson, Bruce; Ford, Anastasia; McGregor, Keith M.; Meinzer, Marcus; Cheshkov, Sergey; Li, Xiufeng; Walker-Batson, Delaina; Briggs, Richard W.

    2010-01-01

    Functional neuroimaging and related neuroimaging techniques are becoming important tools for rehabilitation research. Functional neuroimaging techniques can be used to determine the effects of brain injury or disease on brain systems related to cognition and behavior and to determine how rehabilitation changes brain systems. These techniques include: functional magnetic resonance imaging (fMRI), positron emission tomography (PET), electroencephalography (EEG), magnetoencephalography (MEG), near infrared spectroscopy (NIRS), and transcranial magnetic stimulation (TMS). Related diffusion weighted magnetic resonance imaging techniques (DWI), including diffusion tensor imaging (DTI) and high angular resolution diffusion imaging (HARDI), can quantify white matter integrity. With the proliferation of these imaging techniques in rehabilitation research, it is critical that rehabilitation researchers, as well as consumers of rehabilitation research, become familiar with neuroimaging techniques, what they can offer, and their strengths and weaknesses The purpose to this review is to provide such an introduction to these neuroimaging techniques. PMID:20593321

  3. Effects of Processing and Medical Sterilization Techniques on 3D-Printed and Molded Polylactic Acid

    NASA Astrophysics Data System (ADS)

    Geritano, Mariah Nicole

    Manufacturing industries have evolved tremendously in the past decade with the introduction of Additive Manufacturing (AM), also known as 3D Printing. The medical device industry has been a leader in adapting this new technology into research and development. 3D printing enables medical devices and implants to become more customizable, patient specific, and allows for low production numbers. This study compares the mechanical and thermal properties of traditionally manufactured parts versus parts manufactured through 3D printing before and after sterilization, and the ability of an FDM printer to produce reliable, identical samples. It was found that molded samples and 100% infill high-resolution samples have almost identical changes in properties when exposed to different sterilization methods, and similar cooling rates. The data shown throughout this investigation confirms that manipulation of printing parameters can result in an object with comparable material properties to that created through traditional manufacturing methods.

  4. Non-spectroscopic composition measurements of SrTiO 3-La 0.7Sr 0.3MnO 3 multilayers using scanning convergent beam electron diffraction

    DOE PAGES

    Ophus, Colin; Ercius, Peter; Huijben, Mark; ...

    2017-02-08

    The local atomic structure of a crystalline sample aligned along a zone axis can be probed with a focused electron probe, which produces a convergent beam electron diffraction pattern. The introduction of high speed direct electron detectors has allowed for experiments that can record a full diffraction pattern image at thousands of probe positions on a sample. By incoherently summing these patterns over crystalline unit cells, we demonstrate in this paper that in addition to crystal structure and thickness, we can also estimate the local composition of a perovskite superlattice sample. This is achieved by matching the summed patterns tomore » a library of simulated diffraction patterns. Finally, this technique allows for atomic-scale chemical measurements without requiring a spectrometer or hardware aberration correction.« less

  5. Thermoelectric technique to precisely control hyperthermic exposures of human whole blood.

    PubMed

    DuBose, D A; Langevin, R C; Morehouse, D H

    1996-12-01

    The need in military research to avoid exposing humans to harsh environments and reduce animal use requires the development of in vitro models for the study of hyperthermic injury. A thermoelectric module (TEM) system was employed to heat human whole blood (HWB) in a manner similar to that experienced by heat-stroked rats. This system precisely and accurately replicated mild, moderate, and extreme heat-stress exposures. Temperature changes could be monitored without the introduction of a test sample thermistor, which reduced contamination problems. HWB with hematocrits of 45 or 50% had similar heating curves, indicating that the system compensated for differences in sample character. The unit's size permitted its containment within a standard carbon dioxide incubator to further control sample environment. These results indicate that the TEM system can precisely control temperature change in this heat stress in vitro model employing HWB. Information obtained from such a model could contribute to military preparedness.

  6. Elemental analyses of goundwater: demonstrated advantage of low-flow sampling and trace-metal clean techniques over standard techniques

    NASA Astrophysics Data System (ADS)

    Creasey, C. L.; Flegal, A. R.

    The combined use of both (1) low-flow purging and sampling and (2) trace-metal clean techniques provides more representative measurements of trace-element concentrations in groundwater than results derived with standard techniques. The use of low-flow purging and sampling provides relatively undisturbed groundwater samples that are more representative of in situ conditions, and the use of trace-element clean techniques limits the inadvertent introduction of contaminants during sampling, storage, and analysis. When these techniques are applied, resultant trace-element concentrations are likely to be markedly lower than results based on standard sampling techniques. In a comparison of data derived from contaminated and control groundwater wells at a site in California, USA, trace-element concentrations from this study were 2-1000 times lower than those determined by the conventional techniques used in sampling of the same wells prior to (5months) and subsequent to (1month) the collections for this study. Specifically, the cadmium and chromium concentrations derived using standard sampling techniques exceed the California Maximum Contaminant Levels (MCL), whereas in this investigation concentrations of both of those elements are substantially below their MCLs. Consequently, the combined use of low-flow and trace-metal clean techniques may preclude erroneous reports of trace-element contamination in groundwater. Résumé L'utilisation simultanée de la purge et de l'échantillonnage à faible débit et des techniques sans traces de métaux permet d'obtenir des mesures de concentrations en éléments en traces dans les eaux souterraines plus représentatives que les résultats fournis par les techniques classiques. L'utilisation de la purge et de l'échantillonnage à faible débit donne des échantillons d'eau souterraine relativement peu perturbés qui sont plus représentatifs des conditions in situ, et le recours aux techniques sans éléments en traces limite l'introduction accidentelle de contaminants au cours de l'échantillonnage, du stockage et de l'analyse. Lorsque ces techniques sont appliquées, les concentrations résultantes en éléments en traces sont nettement plus faibles que les résultats obtenus par les techniques d'échantillonnage classique. Dans une comparaison de données concernant des puits contaminés et des puits de contrôle d'un site de Californie (États-Unis), les concentrations en éléments en traces de cette étude ont été de 2 à 1000 fois plus faibles que celles déterminées par les techniques conventionnelles utilisées pour l'échantillonnage des mêmes puits cinq mois auparavant et un mois après ces prélèvements. En particulier, les concentrations en cadmium et en chrome obtenues par les techniques classiques de prélèvements dépassent les teneurs maximales admises en Californie, alors que les concentrations obtenues pour ces deux éléments dans cette étude sont nettement au-dessous de ces teneurs maximales. Par conséquent, le recours à des techniques à faible débit et sans traces de métal peut faire apparaître que la publication de contamination d'eaux souterraines par des éléments en traces était erronée. Resumen El uso combinado del purgado y muestreo a bajo caudal con las técnicas limpias de metales traza proporcionan medidas de la concentración de elementos traza en las aguas subterráneas que son más representativas que las obtenidas con técnicas tradicionales. El purgado y muestreo a bajo caudal proporciona muestras de agua prácticamente inalteradas, representativas de las condiciones en el terreno. Las técnicas limpias de metales traza limitan la no deseada introducción de contaminantes durante el muestreo, almacenamiento y análisis. Las concentraciones de elementos traza resultantes suelen ser bastante menores que las obtenidas por técnicas tradicionales. En una comparación entre los datos procedentes de pozos en California, las concentraciones obtenidas con el nuevo método fueron entre 2-1000 menores que las obtenidas mediante técnicas tradicionales en campañas anteriores (5 meses) y posteriores (1 mes) llevadas a cabo en los mismos pozos. Específicamente, las concentraciones de cadmio y cromo obtenidas mediante técnicas tradicionales superaban los Límites Máximos de Concentración en California (LMC), mientras que los valores obtenidos en este estudio estaban claramente por debajo de estos límites para ambos elementos. Esto demuestra la utilidad del método combinado.

  7. A hydrophobic ionic liquid compartmentalized sampling/labeling and its separation techniques in polydimethylsiloxane microchip capillary electrophoresis.

    PubMed

    Quan, Hong Hua; Li, Ming; Huang, Yan; Hahn, Jong Hoon

    2017-01-01

    This paper demonstrates a novel compartmentalized sampling/labeling method and its separation techniques using a hydrophobic ionic liquid (IL)-1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)-imidate (BmimNTf 2 )-as the immiscible phase, which is capable of minimizing signal losses during microchip capillary electrophoresis (MCE). The MCE device consists of a silica tube connected to a straight polydimethylsiloxane (PDMS) separation channel. Poly(diallyldimethylammonium chloride) (PDDAC) was coated on the inner surface of channel to ease the introduction of IL plugs and enhance the IL wetting on the PDMS surface for sample releasing. Electroosmotic flow (EOF)-based sample compartmentalization was carried out through a sequenced injection into sampling tubes with the following order: leading IL plug/sample segment/terminal IL plug. The movement of the sample segment was easily controlled by applying an electrical voltage across both ends of the chip without a sample volume change. This approach effectively prevented analyte diffusion before injection into MCE channels. When the sample segment was manipulated to the PDDAC-modified PDMS channel, the sample plug then was released from isolation under EOF while IL plugs adsorbed onto channel surfaces owing to strong adhesion. A mixture of flavin adenine nucleotides (FAD) and flavin mononucleotides (FMN) was successfully separated on a 2.5 cm long separation channel, for which the theoretical numbers of plates were 15 000 and 17 000, respectively. The obtained peak intensity was increased 6.3-fold over the corresponding value from conventional electrokinetic injection with the same sampling time. Furthermore, based on the compartmented sample segment serving as an interim reactor, an on-chip fluorescence labeling is demonstrated. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Clinical application of high throughput molecular screening techniques for pharmacogenomics

    PubMed Central

    Wiita, Arun P; Schrijver, Iris

    2011-01-01

    Genetic analysis is one of the fastest-growing areas of clinical diagnostics. Fortunately, as our knowledge of clinically relevant genetic variants rapidly expands, so does our ability to detect these variants in patient samples. Increasing demand for genetic information may necessitate the use of high throughput diagnostic methods as part of clinically validated testing. Here we provide a general overview of our current and near-future abilities to perform large-scale genetic testing in the clinical laboratory. First we review in detail molecular methods used for high throughput mutation detection, including techniques able to monitor thousands of genetic variants for a single patient or to genotype a single genetic variant for thousands of patients simultaneously. These methods are analyzed in the context of pharmacogenomic testing in the clinical laboratories, with a focus on tests that are currently validated as well as those that hold strong promise for widespread clinical application in the near future. We further discuss the unique economic and clinical challenges posed by pharmacogenomic markers. Our ability to detect genetic variants frequently outstrips our ability to accurately interpret them in a clinical context, carrying implications both for test development and introduction into patient management algorithms. These complexities must be taken into account prior to the introduction of any pharmacogenomic biomarker into routine clinical testing. PMID:23226057

  9. Detection, Occurrence and Fate of Emerging Contaminants in Agricultural Environments

    PubMed Central

    Cassada, David A.; Bartelt–Hunt, Shannon L.; Li, Xu; D’Alessio, Matteo; Zhang, Yun; Zhang, Yuping; Sallach, J. Brett

    2018-01-01

    A total of 59 papers published in 2015 were reviewed ranging from detailed descriptions of analytical methods, to fate and occurrence studies, to ecological effects and sampling techniques for a wide variety of emerging contaminants likely to occur in agricultural environments. New methods and studies on veterinary pharmaceuticals, steroids, antibiotic resistance genes in agricultural environments continue to expand our knowledge base on the occurrence and potential impacts of these compounds. This review is divided into the following sections: Introduction, Analytical Methods, Steroid Hormones, Pharmaceutical Contaminants, Transformation Products, and “Antibiotic Resistance, Drugs, Bugs and Genes”. PMID:27620078

  10. SYSTEM OPTIMIZATION FOR THE AUTOMATIC SIMULTANEOUS DETERMINATION OF ARSENIC, SELENIUM, AND ANTIMONY, USING HYDRIDE GENERATION INTRODUCTION TO AN INDUCTIVELY COUPLED PLASMA.

    USGS Publications Warehouse

    Pyen, Grace S.; Browner, Richard F.; Long, Stephen

    1986-01-01

    A fixed-size simplex has been used to determine the optimum conditions for the simultaneous determination of arsenic, selenium, and antimony by hydride generation and inductively coupled plasma emission spectrometry. The variables selected for the simplex were carrier gas flow rate, rf power, viewing height, and reagent conditions. The detection limit for selenium was comparable to the preoptimized case, but there were twofold and fourfold improvements in the detection limits for arsenic and antimony, respectively. Precision of the technique was assessed with the use of artificially prepared water samples.

  11. High-resolution mass spectrometry in toxicology: current status and future perspectives.

    PubMed

    Maurer, H H; Meyer, Markus R

    2016-09-01

    This paper reviews high-resolution mass spectrometry (HRMS) approaches using time-of-flight or Orbitrap techniques for research and application in various toxicology fields, particularly in clinical toxicology and forensic toxicology published since 2013 and referenced in PubMed. In the introduction, an overview on applications of HRMS in various toxicology fields is given with reference to current review articles. Papers concerning HRMS in metabolism, screening, and quantification of pharmaceuticals, drugs of abuse, and toxins in human body samples are critically reviewed. Finally, a discussion on advantages as well as limitations and future perspectives of these methods is included.

  12. A review of separation methods for the determination of estrogens and plastics-derived estrogen mimics from aqueous systems.

    PubMed

    LaFleur, Alesha D; Schug, Kevin A

    2011-06-24

    Recent methods of separation and detection for the quantification of trace-level concentrations of selected endocrine disrupting compounds (EDCs) from aqueous systems are reviewed. A brief introduction of the selected EDCs (natural and synthetic estrogens and plastics-derived xenoestrogens), including their characteristics and importance, is presented. Sample preparation and extraction trends are discussed. Various types of separation techniques are presented, with the express goal of emphasizing time and cost-effective methods that isolate and quantify trace-levels of multiple endocrine disruptors from aqueous systems. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Microfabrication Techniques for Plastic Microelectromechanical Systems (MEMS)

    DTIC Science & Technology

    2003-07-01

    micromachining techniques were investigated. Surface micromachining techniques include deposition of thin and thick polymer films using vacuum and spin ...1 2.0 Introduction ...100 4.3.1 Nozzle-diffuser pumps theory

  14. Organophosphate flame retardants in household dust before and after introduction of new furniture.

    PubMed

    Keimowitz, A R; Strunsky, N; Wovkulich, K

    2016-04-01

    Flame retardant compounds originating from household items collect in household dust, a reasonable proxy for human exposure. Contributions of specific items or behaviors to dust are difficult to separate. This study examined standardized college housing before and after the introduction of new, flame retardant couches in order to explore any effect that changing upholstered furniture may have on flame retardant concentrations in dust. Two contradictory hypotheses were posited: (1) that new furniture might increase flame retardant releases immediately after introduction due to initial off-gassing of new materials or (2) that older furniture would release more flame retardants due to mechanical breakdown of polyurethane foam. This study was designed to determine which of these processes dominated. Prior to the introduction of new furniture, TDCIPP was detected in 12/20 samples at a median concentration of 22 μg/g and TCEP was detected in 1/20 samples at a concentration of 16 μg/g. TDCIPP and TCEP were not detected in any samples (N = 29) after the introduction of new couches. TPHP was detected both before (in 11/20 samples) and after (in 5/29 samples) introduction of new couches; the median concentrations before and after were 63 ± 49 and 16 ± 11 μg/g (standard deviation shown). Introduced couches contained TDCIPP (and not TPHP) at ∼1.25% (w/w). These data support the second hypothesis and indicate that removal of older furniture decreases TDCIPP and TCEP concentrations in dust and may potentially reduce total flame retardant concentrations in dust, at least immediately after introduction of the new furniture. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Applications of inductively coupled plasma-mass spectrometry in environmental radiochemistry

    USGS Publications Warehouse

    Grain, J.S.

    1996-01-01

    The state of the art in ICP-MS is now such that there are few discernible differences between radiochemical and mass spectrometric determinations of longlived radionuclides. Indeed, ICP-MS may provide better (more sensitive) data for many radionuclides, depending upon how one wishes to define "long-lived." In lowlevel determinations, sample preparation remains an important part of the analytical procedure, even with ICP-MS, but the speed and isotopic selectivity of the mass spectrometer appear to offer distinct procedural advantages over radiochemical techniques. Therefore, "radioanalytical" ICP-MS applications should continue to grow, especially in the area of radiation protection, but further research (on efficient sample introduction, for example) and method development may be required to get ICP-MS "off the ground" in the geochemical research areas that have traditionally been supported by radiochemistry.

  16. Pressure-assisted introduction of urine samples into a short capillary for electrophoretic separation with contactless conductivity and UV spectrometry detection.

    PubMed

    Makrlíková, Anna; Opekar, František; Tůma, Petr

    2015-08-01

    A computer-controlled hydrodynamic sample introduction method has been proposed for short-capillary electrophoresis. In the method, the BGE flushes sample from the loop of a six-way sampling valve and is carried to the injection end of the capillary. A short pressure impulse is generated in the electrolyte stream at the time when the sample zone is at the capillary, leading to injection of the sample into the capillary. Then the electrolyte flow is stopped and the separation voltage is turned on. This way of sample introduction does not involve movement of the capillary and both of its ends remain constantly in the solution during both sample injection and separation. The amount of sample introduced to the capillary is controlled by the duration of the pressure pulse. The new sample introduction method was tested in the determination of ammonia, creatinine, uric acid, and hippuric acid in human urine. The determination was performed in a capillary with an overall length of 10.5 cm, in two BGEs with compositions 50 mM MES + 5 mM NaOH (pH 5.1) and 1 M acetic acid + 1.5 mM crown ether 18-crown-6 (pH 2.4). A dual contactless conductivity/UV spectrometric detector was used for the detection. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. A Lagrangian Analysis of a Developing and Non-Developing Disturbance Observed During the PREDICT Experiment

    DTIC Science & Technology

    2012-12-03

    paper provides an introduction of Lagrangian techniques for locating flow boundaries that encompass regions of recirculation in time- dependent flows...the low- to mid- level embryonic vortex from adverse conditions, while the 1The glossary on NOAA’s Hurricane Research Division’s web - site uses...wave or disturbance. This paper provides an introduction of Lagrangian techniques for locating flow boundaries that encompass regions of recirculation

  18. Ionic liquids in solid-phase microextraction: a review.

    PubMed

    Ho, Tien D; Canestraro, Anthony J; Anderson, Jared L

    2011-06-10

    Solid-phase microextraction (SPME) has undergone a surge in popularity within the field of analytical chemistry in the past two decades since its introduction. Owing to its nature of extraction, SPME has become widely known as a quick and cost-effective sample preparation technique. Although SPME has demonstrated extraordinary versatility in sampling capabilities, the technique continues to experience a tremendous growth in innovation. Presently, increasing efforts have been directed towards the engineering of novel sorbent material in order to expand the applicability of SPME for a wider range of analytes and matrices. This review highlights the application of ionic liquids (ILs) and polymeric ionic liquids (PILs) as innovative sorbent materials for SPME. Characterized by their unique physico-chemical properties, these compounds can be structurally-designed to selectively extract target analytes based on unique molecular interactions. To examine the advantages of IL and PIL-based sorbent coatings in SPME, the field is reviewed by gathering available experimental data and exploring the sensitivity, linear calibration range, as well as detection limits for a variety of target analytes in the methods that have been developed. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Surface-enhanced Raman spectroscopy applied to food safety.

    PubMed

    Craig, Ana Paula; Franca, Adriana S; Irudayaraj, Joseph

    2013-01-01

    Surface-enhanced Raman spectroscopy (SERS) is an advanced Raman technique that enhances the vibrational spectrum of molecules adsorbed on or in the vicinity of metal particles and/or surfaces. Because of its readiness, sensitivity, and minimum sample preparation requirements, SERS is being considered as a powerful technique for food inspection. Key aspects of food-safety assurance, spectroscopy methods, and SERS are briefly discussed in an extended introduction of this review. The recent and potential advances in SERS are highlighted in sections that deal with the (a) detection of food-borne pathogenic microorganisms and (b) the detection of food contaminants and adulteration, concentrated specifically on antibiotics, drugs, hormones, melamine, and pesticides. This review provides an outlook of the work done and a perspective on the future directions of SERS as a reliable tool for food-safety assessment.

  20. An Introduction to Using Surface Geophysics to Characterize Sand and Gravel Deposits

    USGS Publications Warehouse

    Lucius, Jeffrey E.; Langer, William H.; Ellefsen, Karl J.

    2006-01-01

    This report is an introduction to surface geophysical techniques that aggregate producers can use to characterize known deposits of sand and gravel. Five well-established and well-tested geophysical methods are presented: seismic refraction and reflection, resistivity, ground penetrating radar, time-domain electromagnetism, and frequency-domain electromagnetism. Depending on site conditions and the selected method(s), geophysical surveys can provide information concerning aerial extent and thickness of the deposit, thickness of overburden, depth to the water table, critical geologic contacts, and location and correlation of geologic features. In addition, geophysical surveys can be conducted prior to intensive drilling to help locate auger or drill holes, reduce the number of drill holes required, calculate stripping ratios to help manage mining costs, and provide continuity between sampling sites to upgrade the confidence of reserve calculations from probable reserves to proved reserves. Perhaps the greatest value of geophysics to aggregate producers may be the speed of data acquisition, reduced overall costs, and improved subsurface characterization.

  1. An Introduction to Using Surface Geophysics to Characterize Sand and Gravel Deposits

    USGS Publications Warehouse

    Lucius, Jeffrey E.; Langer, William H.; Ellefsen, Karl J.

    2007-01-01

    This report is an introduction to surface geophysical techniques that aggregate producers can use to characterize known deposits of sand and gravel. Five well-established and well-tested geophysical methods are presented: seismic refraction and reflection, resistivity, ground penetrating radar, time-domain electromagnetism, and frequency-domain electromagnetism. Depending on site conditions and the selected method(s), geophysical surveys can provide information concerning areal extent and thickness of the deposit, thickness of overburden, depth to the water table, critical geologic contacts, and location and correlation of geologic features. In addition, geophysical surveys can be conducted prior to intensive drilling to help locate auger or drill holes, reduce the number of drill holes required, calculate stripping ratios to help manage mining costs, and provide continuity between sampling sites to upgrade the confidence of reserve calculations from probable reserves to proved reserves. Perhaps the greatest value of geophysics to aggregate producers may be the speed of data acquisition, reduced overall costs, and improved subsurface characterization.

  2. Assessing acceptability of parents/guardians of adolescents towards introduction of sex and reproductive health education in schools at Kinondoni Municipal in Dar es Salaam city.

    PubMed

    Mbonile, Lumuli; Kayombo, Edmund J

    2008-04-01

    To assess acceptability of parents/guardians of adolescents towards the introduction of sex and reproductive health education in the community and schools. A multi-stage random sampling technique was used to get 150 participants for this study. A structured questionnaire was used to interview the sampled participants and was supplemented with guided focus group discussion in Kinondoni Municipality of Dar es Salaam, Tanzania. The analysis of the findings shows that there is a mixed feeling on the introduction of sex and reproductive health education in schools. Participants strongly supported that they should talk with their adolescents about sexuality and reproductive health (88.6%) but their culture prohibits them from doing so (76.7%). Also supported that condoms could protect against HIV/AIDS and sexually transmitted infections (82%), but strongly opposed the use of condoms to their adolescents because it would encourage promiscuity (78%). When the data were analysed by faith of the religions of the participants, 64% were in favour of introducing sex education and reproductive health, but were opposed to use of condoms to their adolescents. All participants were against vijiweni, which were recreation centres for the youths because they taught bad manners to their adolescents. The preferred source of information about sex education and reproductive health should be from the parents/guardians (86%), religious leaders (70%), media (62%), health workers (61%) and school teachers (59%). All in all the will of introduction of sex education and reproductive health in the community is there but the approach need to be worked out carefully by taking into account of the cultural and religious factors. Parents/guardians, religious leaders and traditional charismatic leaders should take part in designing the programme and even being involved in teaching it. The other option is to lump together sex education and reproductive health education in science especially in biology which is already in place in Tanzania education programmes.

  3. An intelligent signal processing and pattern recognition technique for defect identification using an active sensor network

    NASA Astrophysics Data System (ADS)

    Su, Zhongqing; Ye, Lin

    2004-08-01

    The practical utilization of elastic waves, e.g. Rayleigh-Lamb waves, in high-performance structural health monitoring techniques is somewhat impeded due to the complicated wave dispersion phenomena, the existence of multiple wave modes, the high susceptibility to diverse interferences, the bulky sampled data and the difficulty in signal interpretation. An intelligent signal processing and pattern recognition (ISPPR) approach using the wavelet transform and artificial neural network algorithms was developed; this was actualized in a signal processing package (SPP). The ISPPR technique comprehensively functions as signal filtration, data compression, characteristic extraction, information mapping and pattern recognition, capable of extracting essential yet concise features from acquired raw wave signals and further assisting in structural health evaluation. For validation, the SPP was applied to the prediction of crack growth in an alloy structural beam and construction of a damage parameter database for defect identification in CF/EP composite structures. It was clearly apparent that the elastic wave propagation-based damage assessment could be dramatically streamlined by introduction of the ISPPR technique.

  4. A novel, two-step top seeded infiltration and growth process for the fabrication of single grain, bulk (RE)BCO superconductors

    NASA Astrophysics Data System (ADS)

    Namburi, Devendra K.; Shi, Yunhua; Palmer, Kysen G.; Dennis, Anthony R.; Durrell, John H.; Cardwell, David A.

    2016-09-01

    A fundamental requirement of the fabrication of high performing, (RE)-Ba-Cu-O bulk superconductors is achieving a single grain microstructure that exhibits good flux pinning properties. The top seeded melt growth (TSMG) process is a well-established technique for the fabrication of single grain (RE)BCO bulk samples and is now applied routinely by a number of research groups around the world. The introduction of a buffer layer to the TSMG process has been demonstrated recently to improve significantly the general reliability of the process. However, a number of growth-related defects, such as porosity and the formation of micro-cracks, remain inherent to the TSMG process, and are proving difficult to eliminate by varying the melt process parameters. The seeded infiltration and growth (SIG) process has been shown to yield single grain samples that exhibit significantly improved microstructures compared to the TSMG technique. Unfortunately, however, SIG leads to other processing challenges, such as the reliability of fabrication, optimisation of RE2BaCuO5 (RE-211) inclusions (size and content) in the sample microstructure, practical oxygenation of as processed samples and, hence, optimisation of the superconducting properties of the bulk single grain. In the present paper, we report the development of a near-net shaping technique based on a novel two-step, buffer-aided top seeded infiltration and growth (BA-TSIG) process, which has been demonstrated to improve greatly the reliability of the single grain growth process and has been used to fabricate successfully bulk, single grain (RE)BCO superconductors with improved microstructures and superconducting properties. A trapped field of ˜0.84 T and a zero field current density of 60 kA cm-2 have been measured at 77 K in a bulk, YBCO single grain sample of diameter 25 mm processed by this two-step BA-TSIG technique. To the best of our knowledge, this value of trapped field is the highest value ever reported for a sample fabricated by an infiltration and growth process. In this study we report the successful fabrication of 14 YBCO samples, with diameters of up to 32 mm, by this novel technique with a success rate of greater than 92%.

  5. Halo-shaped Flowing Atmospheric Pressure Afterglow – a Heavenly New Design for Simplified Sample Introduction and Improved Ionization in Ambient Mass Spectrometry

    PubMed Central

    Pfeuffer, Kevin P.; Schaper, J. Niklas; Shelley, Jacob T.; Ray, Steven J.; Chan, George C.-Y.; Bings, Nicolas H.; Hieftje, Gary M.

    2013-01-01

    The flowing atmospheric pressure afterglow (FAPA) is a promising new source for atmospheric pressure, ambient desorption/ionization mass spectrometry. However, problems exist with reproducible sample introduction into the FAPA source. To overcome this limitation, a new FAPA geometry has been developed in which concentric tubular electrodes are utilized to form a halo-shaped discharge; this geometry has been termed the halo-FAPA or h-FAPA. With this new geometry, it is still possible to achieve direct desorption and ionization from a surface; however, sample introduction through the inner capillary is also possible and improves interaction between the sample material (solution, vapor, or aerosol) and the plasma to promote desorption and ionization. The h-FAPA operates with a helium gas flow of 0.60 L/min outer, 0.30 L/min inner, applied current of 30 mA at 200 V for 6 watts of power. In addition, separation of the discharge proper and sample material prevents perturbations to the plasma. Optical-emission characterization and gas rotational temperatures reveal that the temperature of the discharge is not significantly affected (< 3% change at 450K) by water vapor during solution-aerosol sample introduction. The primary mass-spectral background species are protonated water clusters, and the primary analyte ions are protonated molecular ions (M+H+). Flexibility of the new ambient sampling source is demonstrated by coupling it with a laser ablation unit, a concentric nebulizer and a droplet-on-demand system for sample introduction. A novel arrangement is also presented in which the central channel of the h-FAPA is used as the inlet to a mass spectrometer. PMID:23808829

  6. Halo-shaped flowing atmospheric pressure afterglow: a heavenly design for simplified sample introduction and improved ionization in ambient mass spectrometry.

    PubMed

    Pfeuffer, Kevin P; Schaper, J Niklas; Shelley, Jacob T; Ray, Steven J; Chan, George C-Y; Bings, Nicolas H; Hieftje, Gary M

    2013-08-06

    The flowing atmospheric-pressure afterglow (FAPA) is a promising new source for atmospheric-pressure, ambient desorption/ionization mass spectrometry. However, problems exist with reproducible sample introduction into the FAPA source. To overcome this limitation, a new FAPA geometry has been developed in which concentric tubular electrodes are utilized to form a halo-shaped discharge; this geometry has been termed the halo-FAPA or h-FAPA. With this new geometry, it is still possible to achieve direct desorption and ionization from a surface; however, sample introduction through the inner capillary is also possible and improves interaction between the sample material (solution, vapor, or aerosol) and the plasma to promote desorption and ionization. The h-FAPA operates with a helium gas flow of 0.60 L/min outer, 0.30 L/min inner, and applied current of 30 mA at 200 V for 6 W of power. In addition, separation of the discharge proper and sample material prevents perturbations to the plasma. Optical-emission characterization and gas rotational temperatures reveal that the temperature of the discharge is not significantly affected (<3% change at 450 K) by water vapor during solution-aerosol sample introduction. The primary mass-spectral background species are protonated water clusters, and the primary analyte ions are protonated molecular ions (M + H(+)). Flexibility of the new ambient sampling source is demonstrated by coupling it with a laser ablation unit, a concentric nebulizer, and a droplet-on-demand system for sample introduction. A novel arrangement is also presented in which the central channel of the h-FAPA is used as the inlet to a mass spectrometer.

  7. Wispy Prosthesis: A Novel Method in Denture Weight Reduction

    PubMed Central

    Anne, Gopinadh; Budeti, Sreedevi; Anche, Sampath Kumar; Zakkula, Srujana; Atla, Jyothi; Jyothula, Ravi Rakesh Dev; Peddinti, Vijaya Kumar

    2016-01-01

    Introduction Stability and retention of the denture becomes at stake with the increase in weight of the denture prosthesis. As a consequence, different materials and methods have been introduced to overcome these issues but denture weight reduction still remains to be a cumbersome and strenuous procedure. Aim To introduce a novel technique for the fabrication of denture prosthesis where in the weight of the denture will not affect the retention and stability of the denture. Materials and Methods Four groups with a sample size of 10 each, were included where in one group was control and other three were study groups. The control group samples were made completely solid and the study group samples were packed with materials like bean balls, cellulose balls and polyacrylic fibers. The weight of all the samples of each study group was measured and compared with the control group. The observations were analyzed statistically by paired t-test. Results It was observed that the bean balls group produced a weight reduction of 31.3%, cellulose balls group 27.4% and polyacrylic fibers group 24.5% when compared to that of the control group. Conclusion This novel technique will eliminate the problems that were associated in creating hollowness and at the same time will reduce the weight of the prosthesis and among all the study groups, bean balls group were found to reduce maximum weight of the prosthesis. PMID:27190947

  8. Analysis of biofluids in aqueous environment based on mid-infrared spectroscopy.

    PubMed

    Fabian, Heinz; Lasch, Peter; Naumann, Dieter

    2005-01-01

    In this study we describe a semiautomatic Fourier transform infrared spectroscopic methodology for the analysis of liquid serum samples, which combines simple sample introduction with high sample throughput. The applicability of this new infrared technology to the analysis of liquid serum samples from a cohort of cattle naturally infected with bovine spongiform encephalopathy and from controls was explored in comparison to the conventional approach based on transmission infrared spectroscopy of dried serum films. Artifical neural network analysis of the infrared data was performed to differentiate between bovine spongiform encephalopathy-negative controls and animals in the late stage of the disease. After training of artifical neural network classifiers, infrared spectra of sera from an independent external validation data set were analyzed. In this way, sensitivities between 90 and 96% and specificities between 84 and 92% were achieved, respectively, depending upon the strategy of data collection and data analysis. Based on these results, the advantages and limitations of the liquid sample technique and the dried film approach for routine analysis of biofluids are discussed. 2005 Society of Photo-Optical Instrumentation Engineers.

  9. AGARD Flight Test Techniques Series. Volume 14. Introduction to Flight Test Engineering (Introduction a la Technique d’essais en vol)

    DTIC Science & Technology

    1995-09-01

    path and aircraft attitude and other flight or aircraft parameters • Calculations in the frequency domain ( Fast Fourier Transform) • Data analysis...Signal filtering Image processing of video and radar data Parameter identification Statistical analysis Power spectral density Fast Fourier Transform...airspeeds both fast and slow, altitude, load factor both above and below 1g, centers of gravity (fore and aft), and with system/subsystem failures. Whether

  10. Introduction to Computational Physics for Undergraduates

    NASA Astrophysics Data System (ADS)

    Zubairi, Omair; Weber, Fridolin

    2018-03-01

    This is an introductory textbook on computational methods and techniques intended for undergraduates at the sophomore or junior level in the fields of science, mathematics, and engineering. It provides an introduction to programming languages such as FORTRAN 90/95/2000 and covers numerical techniques such as differentiation, integration, root finding, and data fitting. The textbook also entails the use of the Linux/Unix operating system and other relevant software such as plotting programs, text editors, and mark up languages such as LaTeX. It includes multiple homework assignments.

  11. Innovative experimental particle physics through technological advances: Past, present and future

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheung, Harry W.K.; /Fermilab

    This mini-course gives an introduction to the techniques used in experimental particle physics with an emphasis on the impact of technological advances. The basic detector types and particle accelerator facilities will be briefly covered with examples of their use and with comparisons. The mini-course ends with what can be expected in the near future from current technology advances. The mini-course is intended for graduate students and post-docs and as an introduction to experimental techniques for theorists.

  12. An Open Port Sampling Interface for Liquid Introduction Atmospheric Pressure Ionization Mass Spectrometry

    DOE PAGES

    Van Berkel, Gary J.; Kertesz, Vilmos

    2015-08-25

    RATIONALE: A simple method to introduce unprocessed samples into a solvent for rapid characterization by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The continuous flow, self-cleaning open port sampling interface introduced here fills this void. METHODS: The open port sampling interface used a vertically aligned, co-axial tube arrangement enabling solvent delivery to the sampling end of the device through the tubing annulus and solvent aspiration down the center tube and into the mass spectrometer ionization source via the commercial APCI emitter probe. The solvent delivery rate to the interface was set to exceed the aspiration rate creatingmore » a continuous sampling interface along with a constant, self-cleaning spillover of solvent from the top of the probe. RESULTS: Using the open port sampling interface with positive ion mode APCI and a hybrid quadrupole time of flight mass spectrometer, rapid, direct sampling and analysis possibilities are exemplified with plastics, ballpoint and felt tip ink pens, skin, and vegetable oils. These results demonstrated that the open port sampling interface could be used as a simple, versatile and self-cleaning system to rapidly introduce multiple types of unprocessed, sometimes highly concentrated and complex, samples into a solvent flow stream for subsequent ionization and analysis by mass spectrometry. The basic setup presented here could be incorporated with any self-aspirating liquid introduction ionization source (e.g., ESI, APCI, APPI, ICP, etc.) or any type of atmospheric pressure sampling ready mass spectrometer system. CONCLUSIONS: The open port sampling interface provides a means to introduce and quickly analyze unprocessed solid or liquid samples with liquid introduction atmospheric pressure ionization source without fear of sampling interface or ionization source contamination.« less

  13. Bayesian Probability Theory

    NASA Astrophysics Data System (ADS)

    von der Linden, Wolfgang; Dose, Volker; von Toussaint, Udo

    2014-06-01

    Preface; Part I. Introduction: 1. The meaning of probability; 2. Basic definitions; 3. Bayesian inference; 4. Combinatrics; 5. Random walks; 6. Limit theorems; 7. Continuous distributions; 8. The central limit theorem; 9. Poisson processes and waiting times; Part II. Assigning Probabilities: 10. Transformation invariance; 11. Maximum entropy; 12. Qualified maximum entropy; 13. Global smoothness; Part III. Parameter Estimation: 14. Bayesian parameter estimation; 15. Frequentist parameter estimation; 16. The Cramer-Rao inequality; Part IV. Testing Hypotheses: 17. The Bayesian way; 18. The frequentist way; 19. Sampling distributions; 20. Bayesian vs frequentist hypothesis tests; Part V. Real World Applications: 21. Regression; 22. Inconsistent data; 23. Unrecognized signal contributions; 24. Change point problems; 25. Function estimation; 26. Integral equations; 27. Model selection; 28. Bayesian experimental design; Part VI. Probabilistic Numerical Techniques: 29. Numerical integration; 30. Monte Carlo methods; 31. Nested sampling; Appendixes; References; Index.

  14. Laser ablation inductively coupled plasma mass spectrometry measurement of isotope ratios in depleted uranium contaminated soils.

    PubMed

    Seltzer, Michael D

    2003-09-01

    Laser ablation of pressed soil pellets was examined as a means of direct sample introduction to enable inductively coupled plasma mass spectrometry (ICP-MS) screening of soils for residual depleted uranium (DU) contamination. Differentiation between depleted uranium, an anthropogenic contaminant, and naturally occurring uranium was accomplished on the basis of measured 235U/238U isotope ratios. The amount of sample preparation required for laser ablation is considerably less than that typically required for aqueous sample introduction. The amount of hazardous laboratory waste generated is diminished accordingly. During the present investigation, 235U/238U isotope ratios measured for field samples were in good agreement with those derived from gamma spectrometry measurements. However, substantial compensation was required to mitigate the effects of impaired pulse counting attributed to sample inhomogeneity and sporadic introduction of uranium analyte into the plasma.

  15. Human Immune Function and Microbial Pathogenesis in Human Spaceflight

    NASA Technical Reports Server (NTRS)

    Pierson, Duane J.; Ott, M.

    2006-01-01

    This oral presentation was requested by Conference conveners. The requested subject is microbial risk assessment considering changes in the human immune system during flight and microbial diversity of environmental samples aboard the International Space Station (ISS). The presentation will begin with an introduction discussing the goals and limitations of microbial risk assessment during flight. The main portion of the presentation will include changes in the immune system that have been published, historical data from microbial analyses, and initial modeling of the environmental flora aboard ISS. The presentation will conclude with future goals and techniques to enhance our ability to perform microbial risk assessment on long duration missions.

  16. Dual-opposite injection capillary electrophoresis: Principles and misconceptions.

    PubMed

    Blackney, Donna M; Foley, Joe P

    2017-03-01

    Dual-opposite injection capillary electrophoresis (DOI-CE) is a separation technique that utilizes both ends of the capillary for sample introduction. The electroosmotic flow (EOF) is suppressed to allow all ions to reach the detector quickly. Depending on the individual electrophoretic mobilities of the analytes of interest and the effective length that each analyte travels to the detection window, the elution order of analytes in a DOI-CE separation can vary widely. This review discusses the principles, applications, and limitations of dual-opposite injection capillary electrophoresis. Common misconceptions regarding DOI-CE are clarified. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Solid Lubrication Fundamentals and Applications: Introduction and Background. Revision 1

    NASA Technical Reports Server (NTRS)

    Miyoshi, Kazuhisa

    1998-01-01

    This chapter presents an introduction and historical background to the field of tribology, especially solid lubrication and lubricants and sets them in the perspective of techniques and materials in lubrication. Also, solid and liquid lubrication films are defined and described.

  18. Solid Lubrication Fundamentals and Applications. Chapter 1; Introduction and Background

    NASA Technical Reports Server (NTRS)

    Miyoshi, Kazuhisa

    1996-01-01

    This chapter presents an introduction and historical background to the field of tribology, especially solid lubrication and lubricants and sets them in the perspective of techniques and materials in lubrication. Also, solid and liquid lubrication films are defined and described.

  19. Introduction to Geostatistics

    NASA Astrophysics Data System (ADS)

    Kitanidis, P. K.

    1997-05-01

    Introduction to Geostatistics presents practical techniques for engineers and earth scientists who routinely encounter interpolation and estimation problems when analyzing data from field observations. Requiring no background in statistics, and with a unique approach that synthesizes classic and geostatistical methods, this book offers linear estimation methods for practitioners and advanced students. Well illustrated with exercises and worked examples, Introduction to Geostatistics is designed for graduate-level courses in earth sciences and environmental engineering.

  20. Drop-on-demand sample introduction system coupled with the flowing atmospheric-pressure afterglow for direct molecular analysis of complex liquid micro-volume samples

    PubMed Central

    Schaper, J. Niklas; Pfeuffer, Kevin P.; Shelley, Jacob T.; Bings, Nicolas H.

    2012-01-01

    One of the fastest developing fields in analytical spectrochemistry in recent years is ambient desorption/ionization mass spectrometry (ADI-MS). This burgeoning interest has been due to the demonstrated advantages of the method: simple mass spectra, little or no sample preparation, and applicability to samples in the solid, liquid, or gaseous state. One such ADI-MS source, the flowing atmospheric-pressure afterglow (FAPA), is capable of direct analysis of solids just by aiming the source at the solid surface and sampling the produced ions into a mass spectrometer. However, direct introduction of significant volumes of liquid samples into this source has not been possible, as solvent loads can quench the afterglow and, thus, the formation of reagent ions. As a result, the analysis of liquid samples is preferably carried out by analyzing dried residues or by desorbing small amounts of liquid samples directly from the liquid surface. In the former case, reproducibility of sample introduction is crucial if quantitative results are desired. In the present study, introduction of liquid samples as very small droplets helps overcome the issues of sample positioning and reduced levels of solvent intake. A recently developed “drop-on-demand” (DOD) aerosol generator is capable of reproducibly producing very small volumes of liquid (~17 pL). In this paper, the coupling of FAPA-MS and DOD is reported and applications are suggested. Analytes representing different classes of substances were tested and limits of detections were determined. Matrix tolerance was investigated for drugs of abuse and their metabolites by analyzing raw urine samples and quantification without the use of internal standards. Limits of detection below 2 µg/mL, without sample pretreatment, were obtained. PMID:23025277

  1. Drop-on-demand sample introduction system coupled with the flowing atmospheric-pressure afterglow for direct molecular analysis of complex liquid microvolume samples.

    PubMed

    Schaper, J Niklas; Pfeuffer, Kevin P; Shelley, Jacob T; Bings, Nicolas H; Hieftje, Gary M

    2012-11-06

    One of the fastest developing fields in analytical spectrochemistry in recent years is ambient desorption/ionization mass spectrometry (ADI-MS). This burgeoning interest has been due to the demonstrated advantages of the method: simple mass spectra, little or no sample preparation, and applicability to samples in the solid, liquid, or gaseous state. One such ADI-MS source, the flowing atmospheric-pressure afterglow (FAPA), is capable of direct analysis of solids just by aiming the source at the solid surface and sampling the produced ions into a mass spectrometer. However, direct introduction of significant volumes of liquid samples into this source has not been possible, as solvent loads can quench the afterglow and, thus, the formation of reagent ions. As a result, the analysis of liquid samples is preferably carried out by analyzing dried residues or by desorbing small amounts of liquid samples directly from the liquid surface. In the former case, reproducibility of sample introduction is crucial if quantitative results are desired. In the present study, introduction of liquid samples as very small droplets helps overcome the issues of sample positioning and reduced levels of solvent intake. A recently developed "drop-on-demand" (DOD) aerosol generator is capable of reproducibly producing very small volumes of liquid (∼17 pL). In this paper, the coupling of FAPA-MS and DOD is reported and applications are suggested. Analytes representing different classes of substances were tested and limits of detections were determined. Matrix tolerance was investigated for drugs of abuse and their metabolites by analyzing raw urine samples and quantification without the use of internal standards. Limits of detection below 2 μg/mL, without sample pretreatment, were obtained.

  2. Spatial and Temporal Analysis of Populations of the Sudden Oak Death Pathogen in Oregon Forests.

    PubMed

    Kamvar, Z N; Larsen, M M; Kanaskie, A M; Hansen, E M; Grünwald, N J

    2015-07-01

    Sudden oak death caused by the oomycete Phytophthora ramorum was first discovered in California toward the end of the 20th century and subsequently emerged on tanoak forests in Oregon before its first detection in 2001 by aerial surveys. The Oregon Department of Forestry has since monitored the epidemic and sampled symptomatic tanoak trees from 2001 to the present. Populations sampled over this period were genotyped using microsatellites and studied to infer the population genetic history. To date, only the NA1 clonal lineage is established in this region, although three lineages exist on the North American west coast. The original introduction into the Joe Hall area eventually spread to several regions: mostly north but also east and southwest. A new introduction into Hunter Creek appears to correspond to a second introduction not clustering with the early introduction. Our data are best explained by both introductions originating from nursery populations in California or Oregon and resulting from two distinct introduction events. Continued vigilance and eradication of nursery populations of P. ramorum are important to avoid further emergence and potential introduction of other clonal lineages.

  3. Extradural and subarachnoid catheterization using the Seldinger technique.

    PubMed

    Delhaas, E M

    1996-01-01

    The Seldinger technique was developed using a plastic introducer through which introduction and manipulations of a silicone spinal catheter, an extradural stimulation lead or a small diameter fibreoptic scope are possible without the risk of damage to the vulnerable devices. It is not intended as a replacement of the standard technique of introducing a spinal catheter through a Tuohy needle in general anaesthetic practice. Silicone spinal catheters and stimulation leads are used for long-term therapy in intractable chronic pain and spasticity. A fibreoptic scope is used for endoscopic examination of the subarachnoid or extradural space. Using a standard Tuohy needle the soft silicone extradural lead can be damaged easily by manipulations during insertion. For this reason the manufacturer modified the Tuohy needle for extradural silicone lead introduction. The disadvantages of this modified Tuohy needle are: first, difficulty in localization of the extradural space, second, the needle is unsuitable for a subarachnoid catheter or introduction of a fibreoptic scope. The Seldinger technique was performed 25 times in 18 patients, introducing a spinal silicone catheter (n = 14), an extradural silicone stimulation lead (n = 2) or a small diameter fibreoptic endoscope (n = 9). Paraesthesiae caused by neural irritation occurred in awake patients. This did not differ from the technique using a Tuohy needle only. Neural damage or trauma did not occur with the Seldinger technique. The incidence of post-spinal headache was the same for both techniques. No further complications were noted.

  4. Updates on Aspergillus, Pneumocystis and other opportunistic pulmonary mycoses.

    PubMed

    Curbelo, Jose; Galván, Jose María; Aspa, Javier

    2015-12-01

    Mycoses are serious diseases with potentially fatal outcome. The introduction of immunosuppressive treatments and life support techniques has led to a growing prevalence of different degrees of immunosuppression. Compromised immune response is the primary risk factor for the development of opportunistic mycoses. Early diagnosis and treatment are crucial for improving prognosis. However, isolation in cultures or identification using antigen detection techniques cannot distinguish between colonization and invasive infection, and the clinical status of the patient often prevents biopsy sampling. Clinicians thus find themselves in an uncertain position, requiring them to quickly recognize clinical and radiological signs and interpret microbiological results in context. The aim of this review is to provide a general overview of the profile of patients susceptible to these infections, the role of the immune system and, in more detail, the major diagnostic developments that have gained most acceptance and recognition among the scientific community. Copyright © 2014 SEPAR. Published by Elsevier Espana. All rights reserved.

  5. Dynamic P-Technique for Modeling Patterns of Data: Applications to Pediatric Psychology Research

    PubMed Central

    Aylward, Brandon S.; Rausch, Joseph R.

    2011-01-01

    Objective Dynamic p-technique (DPT) is a potentially useful statistical method for examining relationships among dynamic constructs in a single individual or small group of individuals over time. The purpose of this article is to offer a nontechnical introduction to DPT. Method An overview of DPT analysis, with an emphasis on potential applications to pediatric psychology research, is provided. To illustrate how DPT might be applied, an example using simulated data is presented for daily pain and negative mood ratings. Results The simulated example demonstrates the application of DPT to a relevant pediatric psychology research area. In addition, the potential application of DPT to the longitudinal study of adherence is presented. Conclusion Although it has not been utilized frequently within pediatric psychology, DPT could be particularly well-suited for research in this field because of its ability to powerfully model repeated observations from very small samples. PMID:21486938

  6. Dynamic p-technique for modeling patterns of data: applications to pediatric psychology research.

    PubMed

    Nelson, Timothy D; Aylward, Brandon S; Rausch, Joseph R

    2011-10-01

    Dynamic p-technique (DPT) is a potentially useful statistical method for examining relationships among dynamic constructs in a single individual or small group of individuals over time. The purpose of this article is to offer a nontechnical introduction to DPT. An overview of DPT analysis, with an emphasis on potential applications to pediatric psychology research, is provided. To illustrate how DPT might be applied, an example using simulated data is presented for daily pain and negative mood ratings. The simulated example demonstrates the application of DPT to a relevant pediatric psychology research area. In addition, the potential application of DPT to the longitudinal study of adherence is presented. Although it has not been utilized frequently within pediatric psychology, DPT could be particularly well-suited for research in this field because of its ability to powerfully model repeated observations from very small samples.

  7. Advanced Elemental and Isotopic Characterization of Atmospheric Aerosols

    NASA Astrophysics Data System (ADS)

    Shafer, M. M.; Schauer, J. J.; Park, J.

    2001-12-01

    Recent sampling and analytical developments advanced by the project team enable the detailed elemental and isotopic fingerprinting of extremely small masses of atmospheric aerosols. Historically, this type of characterization was rarely achieved due to limitations in analytical sensitivity and a lack of awareness concerning the potential for contamination. However, with the introduction of 3rd and 4th generation ICP-MS instrumentation and the application of state-of-the- art "clean-techniques", quantitative analysis of over 40 elements in sub-milligram samples can be realized. When coupled with an efficient and validated solubilization method, ICP-MS approaches provide distinct advantages in comparison with traditional methods; greatly enhanced detection limits, improved accuracy, and isotope resolution capability, to name a few. Importantly, the ICP-MS approach can readily be integrated with techniques which enable phase differentiation and chemical speciation information to be acquired. For example, selective chemical leaching can provide data on the association of metals with major phase-components, and oxidation state of certain metals. Critical information on metal-ligand stability can be obtained when electrochemical techniques, such as adsorptive cathodic stripping voltammetry (ACSV), are applied to these same extracts. Our research group is applying these techniques in a broad range of research projects to better understand the sources and distribution of trace metals in particulate matter in the atmosphere. Using examples from our research, including recent Pb and Sr isotope ratio work on Asian aerosols, we will illustrate the capabilities and applications of these new methods.

  8. Analysis of chlorophenoxy acid herbicides in water by large-volume on-line derivatization and gas chromatography-mass spectrometry.

    PubMed

    Ding, W H; Liu, C H; Yeh, S P

    2000-10-27

    This work presents a modified method to analyze chlorophenoxy acid herbicides in water samples. The herbicides 2,4-D (2,4-dichlorophenoxyacetic acid). Silvex (2,4,5-trichlorophenoxypropionic acid) and 2,4,5-T (2,4,5-trichlorophenoxyacetic acid) were used to evaluate the method. The method involves extraction of samples by a graphitized carbon black cartridge, and on-line derivatization in the GC injection port using a large-volume (10-20 microl) direct sample introduction (DSI) device with tetraalkylammonium salts. The analytes were then identified and quantitated by ion-trap gas chromatography-mass spectrometry. The large-volume DSI injection-port derivatization technique provides sensitivity, fast and reproducible results for chlorophenoxy acid herbicides residues, to quantitation at 0.1 to 0.2 microg/l in 500-ml water samples. An enhanced characteristic mass chromatogram of molecular ions of butylated chlorophenoxy acid herbicides with a significant chlorine isotope pattern by electron impact ionization MS allows us to determine herbicides residues at trace levels in aqueous samples. Recovery of the herbicide residues in spiked various water samples ranged from 70 to 99% while RSDs ranged from 1 to 13%.

  9. LC-MS/MS signal suppression effects in the analysis of pesticides in complex environmental matrices.

    PubMed

    Choi, B K; Hercules, D M; Gusev, A I

    2001-02-01

    The application of LC separation and mobile phase additives in addressing LC-MS/MS matrix signal suppression effects for the analysis of pesticides in a complex environmental matrix was investigated. It was shown that signal suppression is most significant for analytes eluting early in the LC-MS analysis. Introduction of different buffers (e.g. ammonium formate, ammonium hydroxide, formic acid) into the LC mobile phase was effective in improving signal correlation between the matrix and standard samples. The signal improvement is dependent on buffer concentration as well as LC separation of the matrix components. The application of LC separation alone was not effective in addressing suppression effects when characterizing complex matrix samples. Overloading of the LC column by matrix components was found to significantly contribute to analyte-matrix co-elution and suppression of signal. This signal suppression effect can be efficiently compensated by 2D LC (LC-LC) separation techniques. The effectiveness of buffers and LC separation in improving signal correlation between standard and matrix samples is discussed.

  10. Determination of the rare-earth elements in geological materials by inductively coupled plasma mass spectrometry

    USGS Publications Warehouse

    Lichte, F.E.; Meier, A.L.; Crock, J.G.

    1987-01-01

    A method of analysis of geological materials for the determination of the rare-earth elements using the Inductively coupled plasma mass spectrometric technique (ICP-MS) has been developed. Instrumental parameters and factors affecting analytical results have been first studied and then optimized. Samples are analyzed directly following an acid digestion, without the need for separation or preconcentration with limits of detection of 2-11 ng/g, precision of ?? 2.5% relative standard deviation, and accuracy comparable to inductively coupled plasma emission spectrometry and instrumental neutron activation analysis. A commercially available ICP-MS instrument is used with modifications to the sample introduction system, torch, and sampler orifice to reduce the effects of high salt content of sample solutions prepared from geologic materials. Corrections for isobaric interferences from oxide ions and other diatomic and triatomic ions are made mathematically. Special internal standard procedures are used to compensate for drift in metahmetal oxide ratios and sensitivity. Reference standard values are used to verify the accuracy and utility of the method.

  11. [Spiral CT angiography in practice].

    PubMed

    Pavcec, Zlatko; Zokalj, Ivan; Rumboldt, Zoran; Pal, Andrej; Saghir, Hussein; Ozretić, David; Latin, Branko; Perhoć, Zeljka; Marotti, Miljenko

    2005-01-01

    Incidence of vascular diseases and development of new radiologic techniques in the last three decades has given strong impuls for introduction of non-invasive vascular diagnostic methods. Thanks to the introduction of Doppler ultrasound, new types of computed tomography (CT) and magnetic resonance (MR) scanners, non-invasive vascular diagnostic methods are replacing conventional invasive (catheter) angiographic methods. Computed tomographic angiography (CTA) is a noninvasive vascular diagnostic method based on continuous scanning with CT scanner during intravenous application of contrast material. Performing of CTA is possible after introduction of spiral CT technique whose characteristics are short imaging time and volumetric data acquisition. The main goal of this article, based on our experiences, is to review the role of CTA, performed on single-slice CT scanner, in managment of patients with vascular pathology.

  12. Vector Pursuit Path Tracking for Autonomous Ground Vehicles

    DTIC Science & Technology

    2000-08-01

    vi INTRODUCTION ...........................................................................................................1...other geometric path-tracking techniques. 1 CHAPTER 1 INTRODUCTION An autonomous vehicle is one that is capable of automatic navigation. It is...Joint Architecture for Unmanned Ground Vehicles ( JAUGS ) working group meeting held at the University of Florida. 5 Figure 1.5: Autonomous

  13. Development of a Rapid Point-of-Use DNA Test for the Screening of Genuity® Roundup Ready 2 Yield® Soybean in Seed Samples.

    PubMed

    Chandu, Dilip; Paul, Sudakshina; Parker, Mathew; Dudin, Yelena; King-Sitzes, Jennifer; Perez, Tim; Mittanck, Don W; Shah, Manali; Glenn, Kevin C; Piepenburg, Olaf

    2016-01-01

    Testing for the presence of genetically modified material in seed samples is of critical importance for all stakeholders in the agricultural industry, including growers, seed manufacturers, and regulatory bodies. While rapid antibody-based testing for the transgenic protein has fulfilled this need in the past, the introduction of new variants of a given transgene demands new diagnostic regimen that allows distinguishing different traits at the nucleic acid level. Although such molecular tests can be performed by PCR in the laboratory, their requirement for expensive equipment and sophisticated operation have prevented its uptake in point-of-use applications. A recently developed isothermal DNA amplification technique, recombinase polymerase amplification (RPA), combines simple sample preparation and amplification work-flow procedures with the use of minimal detection equipment in real time. Here, we report the development of a highly sensitive and specific RPA-based detection system for Genuity Roundup Ready 2 Yield (RR2Y) material in soybean (Glycine max) seed samples and present the results of studies applying the method in both laboratory and field-type settings.

  14. Protaper--hybrid technique.

    PubMed

    Simon, Stephane; Lumley, Philip; Tomson, Phillip; Pertot, Wilhelm-Joseph; Machtou, Pierre

    2008-03-01

    Crown down preparation is the most known and described technique since the introduction of Nickel Titanium (NiTi) rotary instruments in endodontics. This technique gives good results but has limitations, such as not addressing the initial anatomy of oval or dumb-bell shaped canals. The specific design of the Protaper instruments allows use of them with a different technique and, specifically, with a brushing motion in the body of the canal. The recent introduction of hand Protaper files has expanded the range of application of this system, especially in curved canals. The 'hybrid technique', using rotary and hand files, and the advantages of the combination of both instruments, are clearly described in this article. Used with this technique, the Protaper is a very safe system to use, and more controllable, for both inexperienced and experienced practitioners alike, than other systems. To understand the precautions needed with rotary files, and how to use them to preserve the anatomy of the canal and get a tapered shaping, even in severely curved canals.

  15. Optimal sampling strategies for detecting zoonotic disease epidemics.

    PubMed

    Ferguson, Jake M; Langebrake, Jessica B; Cannataro, Vincent L; Garcia, Andres J; Hamman, Elizabeth A; Martcheva, Maia; Osenberg, Craig W

    2014-06-01

    The early detection of disease epidemics reduces the chance of successful introductions into new locales, minimizes the number of infections, and reduces the financial impact. We develop a framework to determine the optimal sampling strategy for disease detection in zoonotic host-vector epidemiological systems when a disease goes from below detectable levels to an epidemic. We find that if the time of disease introduction is known then the optimal sampling strategy can switch abruptly between sampling only from the vector population to sampling only from the host population. We also construct time-independent optimal sampling strategies when conducting periodic sampling that can involve sampling both the host and the vector populations simultaneously. Both time-dependent and -independent solutions can be useful for sampling design, depending on whether the time of introduction of the disease is known or not. We illustrate the approach with West Nile virus, a globally-spreading zoonotic arbovirus. Though our analytical results are based on a linearization of the dynamical systems, the sampling rules appear robust over a wide range of parameter space when compared to nonlinear simulation models. Our results suggest some simple rules that can be used by practitioners when developing surveillance programs. These rules require knowledge of transition rates between epidemiological compartments, which population was initially infected, and of the cost per sample for serological tests.

  16. Teacher's Guide to the Future.

    ERIC Educational Resources Information Center

    Murphy, Elaine M.; Cancellier, Patricia

    1982-01-01

    A brief introduction to futures education, an annotated listing of resources, and three ready-to-use student activities are provided. The introduction discusses the benefits of futures education; for example, it encourages students to make responsible decisions about the future. Next, it lists a variety of techniques developed by futurists to…

  17. Direct sample introduction gas chromatography and mass spectrometry for the determination of phthalate esters in cleaning products.

    PubMed

    Cacho, J I; Campillo, N; Viñas, P; Hernández-Córdoba, M

    2015-02-06

    A method using direct sample introduction (DSI) coupled to gas chromatography-mass spectrometry (GC-MS) is developed for the determination of six phthalate esters (dimethyl, diethyl, dibutyl, butylbenzyl, diethylhexyl and dioctyl phthalate) in cleaning products. The different variables involved in the DSI step, including venting time and temperature, vaporisation time and temperature, injector heating temperature and gas flow rate and pressure, were evaluated and optimised using Taguchi orthogonal arrays. The proposed method, using calibration against methanolic standards, showed good linearity in the 0.05-15 μg g(-1) range and good repeatability, with RSD values ranging from 3.5% to 5.7%. Quantification limits between 0.010 and 0.041 μg g(-1), depending on the compound, were attained, while recovery assays provided values from 83% to 115%. Twenty-seven cleaning products were analysed using the DSI-GC-MS method, being four phthalates (dimethyl, diethyl, dibutyl and diethylhexyl phthalate) found in fourteen of them at concentration levels in the 0.1-21 μg g(-1) range. Compared with the most common GC injection technique, which uses the split/splitless injector, the proposed DSI procedure provided larger peak areas and lower detection limits, as result of the greater injected volume and reduction in noise. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Endobronchial ultrasound-guided transbronchial needle aspiration of thyroid: Report of two cases and systematic review of literature

    PubMed Central

    Madan, Karan; Mittal, Saurabh; Hadda, Vijay; Jain, Deepali; Mohan, Anant; Guleria, Randeep

    2016-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive and safe technique for a sampling of mediastinal lesions. Indications for EBUS-TBNA have gradually expanded since its introduction. The usual approach to cytological sampling of the thyroid gland is percutaneous ultrasound-guided fine needle aspiration (US-FNA) performed under local anesthesia. US-FNA may be risky or not feasible in intrathoracic/substernal thyroid location. Feasibility of aspirating thyroid lesions with EBUS-TBNA has been occasionally reported. We report two patients wherein EBUS-TBNA was utilized for thyroid lesion aspiration and definitive diagnosis. We highlight the utility and safety of EBUS-TBNA in the evaluation of intrathoracic thyroid lesions wherein image-guided percutaneous aspiration may be risky/sometimes impossible to perform. A systematic review of literature has also been performed summarizing and discussing the issues pertaining to EBUS-TBNA of the thyroid gland. PMID:27891005

  19. Accelerator radiocarbon dating of evidence for prehistoric horticulture in Illinois

    USGS Publications Warehouse

    Conard, N.; Asch, D.L.; Asch, N.B.; Elmore, D.; Gove, H.; Rubin, M.; Brown, J.A.; Wiant, M.D.; Farnsworth, K.B.; Cook, T.G.

    1984-01-01

    With the development of direct detection radiocarbon dating, which uses an accelerator as part of a highly selective mass spectrometer, it is now possible to determine the age of milligram samples of organic materials1-5. One application of accelerator dating is in evaluating scanty, sometimes controversial evidence for early horticulture throughout the world. We have now used the technique to date small samples of carbonized, cultivated plant remains from archaeological sites in Illinois. The results, reported here, establish (1) that squash was introduced by 7,000 yr ago, 2,500 yr before eastern North American records previously reported; (2) that horticulture involving indigenous plants had begun by 4,000 BP in eastern North America with domestication of Iva annua, a small-seeded annual; (3) that anomalous discoveries of Archaic period maize represent contaminants; and (4) that introduction of maize by initial Middle Woodland times (~2,000 BP) is questionable.

  20. In-situ investigation of protein and DNA structure using UVRRS

    NASA Astrophysics Data System (ADS)

    Greek, L. Shane; Schulze, H. Georg; Blades, Michael W.; Haynes, Charles A.; Turner, Robin F. B.

    1997-05-01

    Ultraviolet resonance Raman spectroscopy (UVRRS) has the potential to become a sensitive, specific, versatile bioanalytical and biophysical technique for routine investigations of proteins, DNA, and their monomeric components, as well as a variety smaller, physiologically important aromatic molecules. The transition of UVRRS from a complex, specialized spectroscopic method to a common laboratory assay depends upon several developments, including a robust sample introduction method permitting routine, in situ analysis in standard laboratory environments. To this end, we recently reported the first fiber-optic probes suitable for deep-UV pulsed laser UVRRS. In this paper, we extend this work by demonstrating the applicability of such probes to studies of biochemical relevance, including investigations of the resonance enhancement of phosphotyrosine, thermal denaturation of RNase T1, and specific and non-specific protein binding. The advantages and disadvantages of the probes are discussed with reference to sample conditions and probe design considerations.

  1. Advances in Molecular Rotational Spectroscopy for Applied Science

    NASA Astrophysics Data System (ADS)

    Harris, Brent; Fields, Shelby S.; Pulliam, Robin; Muckle, Matt; Neill, Justin L.

    2017-06-01

    Advances in chemical sensitivity and robust, solid-state designs for microwave/millimeter-wave instrumentation compel the expansion of molecular rotational spectroscopy as research tool into applied science. It is familiar to consider molecular rotational spectroscopy for air analysis. Those techniques for molecular rotational spectroscopy are included in our presentation of a more broad application space for materials analysis using Fourier Transform Molecular Rotational Resonance (FT-MRR) spectrometers. There are potentially transformative advantages for direct gas analysis of complex mixtures, determination of unknown evolved gases with parts per trillion detection limits in solid materials, and unambiguous chiral determination. The introduction of FT-MRR as an alternative detection principle for analytical chemistry has created a ripe research space for the development of new analytical methods and sampling equipment to fully enable FT-MRR. We present the current state of purpose-built FT-MRR instrumentation and the latest application measurements that make use of new sampling methods.

  2. Molecular dynamics based enhanced sampling of collective variables with very large time steps.

    PubMed

    Chen, Pei-Yang; Tuckerman, Mark E

    2018-01-14

    Enhanced sampling techniques that target a set of collective variables and that use molecular dynamics as the driving engine have seen widespread application in the computational molecular sciences as a means to explore the free-energy landscapes of complex systems. The use of molecular dynamics as the fundamental driver of the sampling requires the introduction of a time step whose magnitude is limited by the fastest motions in a system. While standard multiple time-stepping methods allow larger time steps to be employed for the slower and computationally more expensive forces, the maximum achievable increase in time step is limited by resonance phenomena, which inextricably couple fast and slow motions. Recently, we introduced deterministic and stochastic resonance-free multiple time step algorithms for molecular dynamics that solve this resonance problem and allow ten- to twenty-fold gains in the large time step compared to standard multiple time step algorithms [P. Minary et al., Phys. Rev. Lett. 93, 150201 (2004); B. Leimkuhler et al., Mol. Phys. 111, 3579-3594 (2013)]. These methods are based on the imposition of isokinetic constraints that couple the physical system to Nosé-Hoover chains or Nosé-Hoover Langevin schemes. In this paper, we show how to adapt these methods for collective variable-based enhanced sampling techniques, specifically adiabatic free-energy dynamics/temperature-accelerated molecular dynamics, unified free-energy dynamics, and by extension, metadynamics, thus allowing simulations employing these methods to employ similarly very large time steps. The combination of resonance-free multiple time step integrators with free-energy-based enhanced sampling significantly improves the efficiency of conformational exploration.

  3. Molecular dynamics based enhanced sampling of collective variables with very large time steps

    NASA Astrophysics Data System (ADS)

    Chen, Pei-Yang; Tuckerman, Mark E.

    2018-01-01

    Enhanced sampling techniques that target a set of collective variables and that use molecular dynamics as the driving engine have seen widespread application in the computational molecular sciences as a means to explore the free-energy landscapes of complex systems. The use of molecular dynamics as the fundamental driver of the sampling requires the introduction of a time step whose magnitude is limited by the fastest motions in a system. While standard multiple time-stepping methods allow larger time steps to be employed for the slower and computationally more expensive forces, the maximum achievable increase in time step is limited by resonance phenomena, which inextricably couple fast and slow motions. Recently, we introduced deterministic and stochastic resonance-free multiple time step algorithms for molecular dynamics that solve this resonance problem and allow ten- to twenty-fold gains in the large time step compared to standard multiple time step algorithms [P. Minary et al., Phys. Rev. Lett. 93, 150201 (2004); B. Leimkuhler et al., Mol. Phys. 111, 3579-3594 (2013)]. These methods are based on the imposition of isokinetic constraints that couple the physical system to Nosé-Hoover chains or Nosé-Hoover Langevin schemes. In this paper, we show how to adapt these methods for collective variable-based enhanced sampling techniques, specifically adiabatic free-energy dynamics/temperature-accelerated molecular dynamics, unified free-energy dynamics, and by extension, metadynamics, thus allowing simulations employing these methods to employ similarly very large time steps. The combination of resonance-free multiple time step integrators with free-energy-based enhanced sampling significantly improves the efficiency of conformational exploration.

  4. [Use of MALDI-TOF in the rapid diagnosis of sepsis].

    PubMed

    Carlos Rodríguez, Juan; Ángel Bratos, Miguel; Merino, Esperanza; Ezpeleta, Carmen

    2016-06-01

    The introduction of mass spectrometry through MALDI-TOF (matrix-assisted laser desorption ionization time-of-flight) in the diagnosis of bacteraemia and fungaemia has represented a revolution due to the rapidity and reliability of the results that it can offer to microbiology services and laboratories through analysis of the mass spectrum of the bacterial protein directly from positive blood culture bottles. These data are more useful if they are used in conjunction with other techniques able to identify the antibiotic resistance pattern of the microorganism. There is a need for a process of standardising sample processing protocols and for perfecting the identification of the agents causing bacteraemia, especially in some species of Gram-positive cocci and in polymicrobial processes. The introduction of this methodology provides rapid information that is highly important for the clinical management of bacteraemia. The availability of a multidisciplinary working group that applies all this information quickly and correctly in hospitals will improve the quality of care, reduce antibiotic expenditure and hospital stay and help to control the serious problem of antibiotic resistance. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  5. Estuarial fingerprinting through multidimensional fluorescence and multivariate analysis.

    PubMed

    Hall, Gregory J; Clow, Kerin E; Kenny, Jonathan E

    2005-10-01

    As part of a strategy for preventing the introduction of aquatic nuisance species (ANS) to U.S. estuaries, ballast water exchange (BWE) regulations have been imposed. Enforcing these regulations requires a reliable method for determining the port of origin of water in the ballast tanks of ships entering U.S. waters. This study shows that a three-dimensional fluorescence fingerprinting technique, excitation emission matrix (EEM) spectroscopy, holds great promise as a ballast water analysis tool. In our technique, EEMs are analyzed by multivariate classification and curve resolution methods, such as N-way partial least squares Regression-discriminant analysis (NPLS-DA) and parallel factor analysis (PARAFAC). We demonstrate that classification techniques can be used to discriminate among sampling sites less than 10 miles apart, encompassing Boston Harbor and two tributaries in the Mystic River Watershed. To our knowledge, this work is the first to use multivariate analysis to classify water as to location of origin. Furthermore, it is shown that curve resolution can show seasonal features within the multidimensional fluorescence data sets, which correlate with difficulty in classification.

  6. Commodity-Free Calibration

    NASA Technical Reports Server (NTRS)

    2008-01-01

    Commodity-free calibration is a reaction rate calibration technique that does not require the addition of any commodities. This technique is a specific form of the reaction rate technique, where all of the necessary reactants, other than the sample being analyzed, are either inherent in the analyzing system or specifically added or provided to the system for a reason other than calibration. After introduction, the component of interest is exposed to other reactants or flow paths already present in the system. The instrument detector records one of the following to determine the rate of reaction: the increase in the response of the reaction product, a decrease in the signal of the analyte response, or a decrease in the signal from the inherent reactant. With this data, the initial concentration of the analyte is calculated. This type of system can analyze and calibrate simultaneously, reduce the risk of false positives and exposure to toxic vapors, and improve accuracy. Moreover, having an excess of the reactant already present in the system eliminates the need to add commodities, which further reduces cost, logistic problems, and potential contamination. Also, the calculations involved can be simplified by comparison to those of the reaction rate technique. We conducted tests with hypergols as an initial investigation into the feasiblility of the technique.

  7. Interferometric Dynamic Measurement: Techniques Based on High-Speed Imaging or a Single Photodetector

    PubMed Central

    Fu, Yu; Pedrini, Giancarlo

    2014-01-01

    In recent years, optical interferometry-based techniques have been widely used to perform noncontact measurement of dynamic deformation in different industrial areas. In these applications, various physical quantities need to be measured in any instant and the Nyquist sampling theorem has to be satisfied along the time axis on each measurement point. Two types of techniques were developed for such measurements: one is based on high-speed cameras and the other uses a single photodetector. The limitation of the measurement range along the time axis in camera-based technology is mainly due to the low capturing rate, while the photodetector-based technology can only do the measurement on a single point. In this paper, several aspects of these two technologies are discussed. For the camera-based interferometry, the discussion includes the introduction of the carrier, the processing of the recorded images, the phase extraction algorithms in various domains, and how to increase the temporal measurement range by using multiwavelength techniques. For the detector-based interferometry, the discussion mainly focuses on the single-point and multipoint laser Doppler vibrometers and their applications for measurement under extreme conditions. The results show the effort done by researchers for the improvement of the measurement capabilities using interferometry-based techniques to cover the requirements needed for the industrial applications. PMID:24963503

  8. Measurement of volume resistivity/conductivity of metallic alloy in inhibited seawater by optical interferometry techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Habib, K.

    2011-03-15

    Optical interferometry techniques were used for the first time to measure the volume resistivity/conductivity of carbon steel samples in seawater with different concentrations of a corrosion inhibitor. In this investigation, the real-time holographic interferometry was carried out to measure the thickness of anodic dissolved layer or the total thickness, U{sub total}, of formed oxide layer of carbon steel samples during the alternating current (ac) impedance of the samples in blank seawater and in 5-20 ppm TROS C-70 inhibited seawater, respectively. In addition, a mathematical model was derived in order to correlate between the ac impedance (resistance) and the surface (orthogonal)more » displacement of the surface of the samples in solutions. In other words, a proportionality constant [resistivity ({rho}) or conductivity ({sigma})= 1/{rho}] between the determined ac impedance [by electrochemical impedance spectroscopy (EIS) technique] and the orthogonal displacement (by the optical interferometry techniques) was obtained. The value of the resistivity of the carbon steel sample in the blank seawater was found similar to the value of the resistivity of the carbon steel sample air, around 1 x 10{sup -5}{Omega} cm. On the contrary, the measured values of the resistivity of the carbon steel samples were 1.85 x 10{sup 7}, 3.35 x 10{sup 7}, and 1.7 x 10{sup 7}{Omega} cm in 5, 10, and 20 ppm TROS C-70 inhibited seawater solutions, respectively. Furthermore, the determined value range of {rho} of the formed oxide layers, from 1.7 x 10{sup 7} to 3.35 x 10{sup 7}{Omega} cm, is found in a reasonable agreement with the one found in literature for the Fe oxide-hydroxides, i.e., goethite ({alpha}-FeOOH) and for the lepidocrocite ({gamma}-FeOOH), 1 x 10{sup 9}{Omega} cm. The {rho} value of the Fe oxide-hydroxides, 1 x 10{sup 9}{Omega} cm, was found slightly higher than the {rho} value range of the formed oxide layer of the present study. This is because the former value was determined by a dc method rather than by an electromagnetic method, i.e., holographic interferometry with applications of EIS, i.e., ac method. As a result, erroneous measurements were recorded due to the introduction of heat to Fe oxide-hydroxides.« less

  9. The Reliability and Validity of the Thin Slice Technique: Observational Research on Video Recorded Medical Interactions

    ERIC Educational Resources Information Center

    Foster, Tanina S.

    2014-01-01

    Introduction: Observational research using the thin slice technique has been routinely incorporated in observational research methods, however there is limited evidence supporting use of this technique compared to full interaction coding. The purpose of this study was to determine if this technique could be reliability coded, if ratings are…

  10. Direct sample introduction-gas chromatography-mass spectrometry for the determination of haloanisole compounds in cork stoppers.

    PubMed

    Cacho, J I; Nicolás, J; Viñas, P; Campillo, N; Hernández-Córdoba, M

    2016-12-02

    A solventless analytical method is proposed for analyzing the compounds responsible for cork taint in cork stoppers. Direct sample introduction (DSI) is evaluated as a sample introduction system for the gas chromatography-mass spectrometry (GC-MS) determination of four haloanisoles (HAs) in cork samples. Several parameters affecting the DSI step, including desorption temperature and time, gas flow rate and other focusing parameters, were optimized using univariate and multivariate approaches. The proposed method shows high sensitivity and minimises sample handling, with detection limits of 1.6-2.6ngg -1 , depending on the compound. The suitability of the optimized procedure as a screening method was evaluated by obtaining decision limits (CCα) and detection capabilities (CCβ) for each analyte, which were found to be in 6.9-11.8 and 8.7-14.8ngg -1 , respectively, depending on the compound. Twenty-four cork samples were analysed, and 2,4,6-trichloroanisole was found in four of them at levels between 12.6 and 53ngg -1 . Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Metrological approach to quantitative analysis of clinical samples by LA-ICP-MS: A critical review of recent studies.

    PubMed

    Sajnóg, Adam; Hanć, Anetta; Barałkiewicz, Danuta

    2018-05-15

    Analysis of clinical specimens by imaging techniques allows to determine the content and distribution of trace elements on the surface of the examined sample. In order to obtain reliable results, the developed procedure should be based not only on the properly prepared sample and performed calibration. It is also necessary to carry out all phases of the procedure in accordance with the principles of chemical metrology whose main pillars are the use of validated analytical methods, establishing the traceability of the measurement results and the estimation of the uncertainty. This review paper discusses aspects related to sampling, preparation and analysis of clinical samples by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) with emphasis on metrological aspects, i.e. selected validation parameters of the analytical method, the traceability of the measurement result and the uncertainty of the result. This work promotes the introduction of metrology principles for chemical measurement with emphasis to the LA-ICP-MS which is the comparative method that requires studious approach to the development of the analytical procedure in order to acquire reliable quantitative results. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Isotope ratio analysis by Orbitrap mass spectrometry

    NASA Astrophysics Data System (ADS)

    Eiler, J. M.; Chimiak, L. M.; Dallas, B.; Griep-Raming, J.; Juchelka, D.; Makarov, A.; Schwieters, J. B.

    2016-12-01

    Several technologies are being developed to examine the intramolecular isotopic structures of molecules (i.e., site-specific and multiple substitution), but various limitations in sample size and type or (for IRMS) resolution have so far prevented the creation of a truly general technique. We will discuss the initial findings of a technique based on Fourier transform mass spectrometry, using the Thermo Scientific Q Exactive GC — an instrument that contains an Orbitrap mass analyzer. Fourier transform mass spectrometry is marked by exceptionally high mass resolutions (the Orbitrap reaches M/ΔM in the range 250,000-1M in the mass range of greatest interest, 50-200 amu). This allows for resolution of a large range of nearly isobaric interferences for isotopologues of volatile and semi-volatile compounds (i.e., involving isotopes of H, C, N, O and S). It also provides potential to solve very challenging mass resolution problems for isotopic analysis of other, heavier elements. Both internal and external experimental reproducibilities of isotope ratio analyses using the Orbitrap typically conform to shot-noise limits down to levels of 0.2 ‰ (1SE), and routinely in the range 0.5-1.0 ‰, with similar accuracy when standardized to concurrently run reference materials. Such measurements can be made without modifications to the ion optics of the Q Exactive GC, but do require specially designed sample introduction devices to permit sample/standard comparison and long integration times. The sensitivity of the Q Exactive GC permits analysis of sub-nanomolar samples and quantification of multiply-substituted species. The site-specific capability of this instrument arises from the fact that mass spectra of molecular analytes commonly contain diverse fragment ion species, each of which samples a specific sub-set of molecular sites. We will present applications of this technique to the biological and abiological chemistry of amino acids, forensic identification of hydrocarbon environmental pollutants, and study of the origins of isotope anomalies in meteoritic organics.

  13. [The application of inductively coupled plasma atomic emission spectrometry/mass spectrometry to the analysis of advanced ceramic materials].

    PubMed

    Wang, Zheng; Wang, Shi-Wei; Qiu, De-Ren; Yang, Peng-Yuan

    2009-10-01

    Advanced ceramics have been applied to various important fields such as information science, aeronautics and astronautics, and life sciences. However, the optics and electric properties of ceramics are significantly affected by the micro and trace impurities existing in the material even at very low concentration level. Thus, the accurate determination of impurities is important for materials preparation and performance. Methodology of the analysis of advanced ceramic materials using ICP-AES/MS was reviewed in the present paper for the past decade. Various techniques of sample introduction, especially advances in the authors' recent work, are described in detail. The developing trend is also presented. Sixty references are cited.

  14. Modified electrokinetic sample injection method in chromatography and electrophoresis analysis

    DOEpatents

    Davidson, J. Courtney; Balch, Joseph W.

    2001-01-01

    A sample injection method for horizontal configured multiple chromatography or electrophoresis units, each containing a number of separation/analysis channels, that enables efficient introduction of analyte samples. This method for loading when taken in conjunction with horizontal microchannels allows much reduced sample volumes and a means of sample stacking to greatly reduce the concentration of the sample. This reduction in the amount of sample can lead to great cost savings in sample preparation, particularly in massively parallel applications such as DNA sequencing. The essence of this method is in preparation of the input of the separation channel, the physical sample introduction, and subsequent removal of excess material. By this method, sample volumes of 100 nanoliter to 2 microliters have been used successfully, compared to the typical 5 microliters of sample required by the prior separation/analysis method.

  15. Effective Techniques for the Promotion of Library Services and Resources

    ERIC Educational Resources Information Center

    Yi, Zhixian

    2016-01-01

    Introduction: This study examines how Australian academic librarians perceive techniques for promoting services and resources, and the factors affecting the perceptions regarding effectiveness of techniques used. Method: Data were collected from an online survey that was sent to 400 academic librarians in thirty-seven Australian universities. The…

  16. Automation of static and dynamic non-dispersive liquid phase microextraction. Part 1: Approaches based on extractant drop-, plug-, film- and microflow-formation.

    PubMed

    Alexovič, Michal; Horstkotte, Burkhard; Solich, Petr; Sabo, Ján

    2016-02-04

    Simplicity, effectiveness, swiftness, and environmental friendliness - these are the typical requirements for the state of the art development of green analytical techniques. Liquid phase microextraction (LPME) stands for a family of elegant sample pretreatment and analyte preconcentration techniques preserving these principles in numerous applications. By using only fractions of solvent and sample compared to classical liquid-liquid extraction, the extraction kinetics, the preconcentration factor, and the cost efficiency can be increased. Moreover, significant improvements can be made by automation, which is still a hot topic in analytical chemistry. This review surveys comprehensively and in two parts the developments of automation of non-dispersive LPME methodologies performed in static and dynamic modes. Their advantages and limitations and the reported analytical performances are discussed and put into perspective with the corresponding manual procedures. The automation strategies, techniques, and their operation advantages as well as their potentials are further described and discussed. In this first part, an introduction to LPME and their static and dynamic operation modes as well as their automation methodologies is given. The LPME techniques are classified according to the different approaches of protection of the extraction solvent using either a tip-like (needle/tube/rod) support (drop-based approaches), a wall support (film-based approaches), or microfluidic devices. In the second part, the LPME techniques based on porous supports for the extraction solvent such as membranes and porous media are overviewed. An outlook on future demands and perspectives in this promising area of analytical chemistry is finally given. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Correlating laser-induced breakdown spectroscopy with neutron activation analysis to determine the elemental concentration in the ionome of the Populus trichocarpa leaf

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, Madhavi Z.; Glasgow, David C.; Tschaplinski, Timothy J.

    The black cottonwood poplar (Populus trichocarpa) leaf ionome (inorganic trace elements and mineral nutrients) is an important aspect for determining the physiological and developmental processes contributing to biomass production. A number of techniques are used to measure the ionome, yet characterizing the leaf spatial heterogeneity remains a challenge, especially in solid samples. Laser-induced breakdown spectroscopy (LIBS) has been used to determine the elemental composition of leaves and is able to raster across solid matrixes at 10 μm resolution. Here, we evaluate the use of LIBS for solid sample leaf elemental characterization in relation to neutron activation. In fact, neutron activationmore » analysis is a laboratory-based technique which is used by the National Institute of Standards and Technology (NIST) to certify trace elements in candidate reference materials including plant leaf matrices. Introduction to the techniques used in this research has been presented in this manuscript. Neutron activation analysis (NAA) data has been correlated to the LIBS spectra to achieve quantification of the elements or ions present within poplar leaves. The regression coefficients of calibration and validation using multivariate analysis (MVA) methodology for six out of seven elements have been determined and vary between 0.810 and 0.998. LIBS and NAA data has been presented for the elements such as, calcium, magnesium, manganese, aluminum, copper, and potassium. Chlorine was also detected but it did not show good correlation between the LIBS and NAA techniques. This research shows that LIBS can be used as a fast, high-spatial resolution technique to quantify elements as part of large-scale field phenotyping projects.« less

  18. Correlating laser-induced breakdown spectroscopy with neutron activation analysis to determine the elemental concentration in the ionome of the Populus trichocarpa leaf

    NASA Astrophysics Data System (ADS)

    Martin, Madhavi Z.; Glasgow, David C.; Tschaplinski, Timothy J.; Tuskan, Gerald A.; Gunter, Lee E.; Engle, Nancy L.; Wymore, Ann M.; Weston, David J.

    2017-12-01

    The black cottonwood poplar (Populus trichocarpa) leaf ionome (inorganic trace elements and mineral nutrients) is an important aspect for determining the physiological and developmental processes contributing to biomass production. A number of techniques are used to measure the ionome, yet characterizing the leaf spatial heterogeneity remains a challenge, especially in solid samples. Laser-induced breakdown spectroscopy (LIBS) has been used to determine the elemental composition of leaves and is able to raster across solid matrixes at 10 μm resolution. Here, we evaluate the use of LIBS for solid sample leaf elemental characterization in relation to neutron activation. In fact, neutron activation analysis is a laboratory-based technique which is used by the National Institute of Standards and Technology (NIST) to certify trace elements in candidate reference materials including plant leaf matrices. Introduction to the techniques used in this research has been presented in this manuscript. Neutron activation analysis (NAA) data has been correlated to the LIBS spectra to achieve quantification of the elements or ions present within poplar leaves. The regression coefficients of calibration and validation using multivariate analysis (MVA) methodology for six out of seven elements have been determined and vary between 0.810 and 0.998. LIBS and NAA data has been presented for the elements such as, calcium, magnesium, manganese, aluminum, copper, and potassium. Chlorine was also detected but it did not show good correlation between the LIBS and NAA techniques. This research shows that LIBS can be used as a fast, high-spatial resolution technique to quantify elements as part of large-scale field phenotyping projects.

  19. Correlating laser-induced breakdown spectroscopy with neutron activation analysis to determine the elemental concentration in the ionome of the Populus trichocarpa leaf

    DOE PAGES

    Martin, Madhavi Z.; Glasgow, David C.; Tschaplinski, Timothy J.; ...

    2017-10-17

    The black cottonwood poplar (Populus trichocarpa) leaf ionome (inorganic trace elements and mineral nutrients) is an important aspect for determining the physiological and developmental processes contributing to biomass production. A number of techniques are used to measure the ionome, yet characterizing the leaf spatial heterogeneity remains a challenge, especially in solid samples. Laser-induced breakdown spectroscopy (LIBS) has been used to determine the elemental composition of leaves and is able to raster across solid matrixes at 10 μm resolution. Here, we evaluate the use of LIBS for solid sample leaf elemental characterization in relation to neutron activation. In fact, neutron activationmore » analysis is a laboratory-based technique which is used by the National Institute of Standards and Technology (NIST) to certify trace elements in candidate reference materials including plant leaf matrices. Introduction to the techniques used in this research has been presented in this manuscript. Neutron activation analysis (NAA) data has been correlated to the LIBS spectra to achieve quantification of the elements or ions present within poplar leaves. The regression coefficients of calibration and validation using multivariate analysis (MVA) methodology for six out of seven elements have been determined and vary between 0.810 and 0.998. LIBS and NAA data has been presented for the elements such as, calcium, magnesium, manganese, aluminum, copper, and potassium. Chlorine was also detected but it did not show good correlation between the LIBS and NAA techniques. This research shows that LIBS can be used as a fast, high-spatial resolution technique to quantify elements as part of large-scale field phenotyping projects.« less

  20. Salmon redd identification using environmental DNA (eDNA)

    USGS Publications Warehouse

    Pilliod, David S.; Laramie, Matthew B.

    2016-06-10

    IntroductionThe purpose of this project was to develop a technique to use environmental DNA (eDNA) to distinguish between redds made by Chinook salmon (Oncorhynchus tshawytscha) and redds made by Coho salmon (O. kisutch) and to distinguish utilized redds from test/abandoned redds or scours that have the appearance of redds. The project had two phases:Phase 1. Develop, test, and optimize a molecular assay for detecting and identifying Coho salmon DNA and differentiating it from Chinook salmon DNA.Phase 2. Demonstrate the efficacy of the technique.Collect and preserve water samples from the interstitial spaces of 10 known redds (as identified by expert observers) of each species and 10 gravel patches that do not include a redd of either species.Collect control samples from the water column adjacent to each redd to establish background eDNA levels.Analyze the samples using the developed molecular assays for Coho salmon (phase I) and Chinook salmon (Laramie and others, 2015).Evaluate whether samples collected from Chinook and Coho redds have significantly higher levels of eDNA of the respective species than background levels (that is, from gravel, water column).Evaluate whether samples collected from the interstitial spaces of gravel patches that are not redds are similar to background eDNA levels.The Sandy River is a large tributary of the Columbia River. The Sandy River meets the Columbia River approximately 23 km upstream of Portland, Oregon. The Sandy River Basin provides overlapping spawning habitat for both Chinook and Coho salmon.Samples provided by Portland Water Bureau for analysis were collected from the Bull Run River, Sixes Creek, Still Creek, Arrah Wanna Side Channel, and Side Channel 18.

  1. Advanced functional materials in solid phase extraction for ICP-MS determination of trace elements and their species - A review.

    PubMed

    He, Man; Huang, Lijin; Zhao, Bingshan; Chen, Beibei; Hu, Bin

    2017-06-22

    For the determination of trace elements and their species in various real samples by inductively coupled plasma mass spectrometry (ICP-MS), solid phase extraction (SPE) is a commonly used sample pretreatment technique to remove complex matrix, pre-concentrate target analytes and make the samples suitable for subsequent sample introduction and measurements. The sensitivity, selectivity/anti-interference ability, sample throughput and application potential of the methodology of SPE-ICP-MS are greatly dependent on SPE adsorbents. This article presents a general overview of the use of advanced functional materials (AFMs) in SPE for ICP-MS determination of trace elements and their species in the past decade. Herein the AFMs refer to the materials featuring with high adsorption capacity, good selectivity, fast adsorption/desorption dynamics and satisfying special requirements in real sample analysis, including nanometer-sized materials, porous materials, ion imprinting polymers, restricted access materials and magnetic materials. Carbon/silica/metal/metal oxide nanometer-sized adsorbents with high surface area and plenty of adsorption sites exhibit high adsorption capacity, and porous adsorbents would provide more adsorption sites and faster adsorption dynamics. The selectivity of the materials for target elements/species can be improved by using physical/chemical modification, ion imprinting and restricted accessed technique. Magnetic adsorbents in conventional batch operation offer unique magnetic response and high surface area-volume ratio which provide a very easy phase separation, greater extraction capacity and efficiency over conventional adsorbents, and chip-based magnetic SPE provides a versatile platform for special requirement (e.g. cell analysis). The performance of these adsorbents for the determination of trace elements and their species in different matrices by ICP-MS is discussed in detail, along with perspectives and possible challenges in the future development. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Proceedings of the International Symposium on Shock Tubes and Waves (12th) Held at Jerusalem on 16-19 July 1979.

    DTIC Science & Technology

    1980-02-01

    is also gratefully acknowledged. REFERENCES 1. P.H. Azoury, An Introduction to the Dna-iic Pressure S&c-h’c:4 . Proc. Inst. Mech. Eng. 180, (Pt. 1...crosscorrelation parameters. Practical examples of the ap- plicability to flow fields and combustion diagnostics are presented. INTRODUCTION The appearance of the...laser and its introduction into the field of spec- troscopy was a turning point in the development of light scattering diagnostic techniques. In a

  3. Comparative evaluation of ICP sample introduction systems to be used in the metabolite profiling of chlorine-containing pharmaceuticals via HPLC-ICP-MS.

    PubMed

    Klencsár, Balázs; Sánchez, Carlos; Balcaen, Lieve; Todolí, José; Lynen, Frederic; Vanhaecke, Frank

    2018-05-10

    A systematic evaluation of four different ICP sample introduction systems to be used in the context of metabolite profiling of chlorine-containing pharmaceuticals via HPLC-ICP-MS was carried out using diclofenac and its major metabolite, 4'-hydroxy-diclofenac, as model compounds. The strict requirements for GMP validation of chromatographic methods in the pharmaceutical industry were adhered to in this context. The final aim of this investigation is an extension of the applicability and validatability of HPLC-ICP-MS in the field of pharmaceutical R&D. Five different gradient programmes were tested while the baseline peak width (w b ), peak capacity (P), USP tailing factor (A s ) and USP signal-to-noise ratio (USP S/N) were determined as major indicators of the chromatographic performance and the values obtained were compared to the corresponding FDA recommendations (if applicable). Four different ICP-MS sample introductions systems were investigated involving two units typically working at higher flow rates (∼1.0 mL min -1 ) and another two systems working at lower flow rates (∼0.1 mL min -1 ). Optimal conditions with potential for applicability under GMP conditions were found at a mobile phase flow rate of 1.0 mL min -1 by using a pneumatic micro-flow LC nebulizer mounted onto a Peltier-cooled cyclonic spray chamber cooled to -1 °C for sample introduction. Under these conditions, HPLC-ICP-MS provided a chromatographic performance similar to that of HPLC with UV detection. The peak shape (USP tailing factor = 1.1-1.4) was significantly improved compared to that obtained with the Peltier-cooled Scott-type spray chamber. Two alternative sample introduction systems - a POINT ® and a High-Temperature Torch-Integrated Sample Introduction System (hTISIS) - were also tested at a flow rate of 0.1 mL min -1 using a chromatographic column with 1.0 mm ID. Although these systems allowed the peak shape to be improved compared to that obtained with the traditional Scott-type spray chamber, the limits of detection and of quantification achievable were strongly compromised due to the significantly lower sensitivity observed for Cl. In addition to a comparison of the aforementioned sample introduction systems, also the effect of spray chamber temperature was evaluated and it was demonstrated that proper temperature control plays an essential role in the optimization of HPLC-ICP-MS methods. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Bulgaria: Introduction of Informatics in Education of Children. Project Findings and Recommendations. Terminal Report.

    ERIC Educational Resources Information Center

    United Nations Development Programme, Geneva (Switzerland).

    In 1987, the Bulgarian government and cooperating international agencies launched the program, "Children in the Information Age," a project aimed at: conducting and promoting national research into, exchange of information about, development and application of, practical training in, and methods and techniques for the introduction of…

  5. Governmentality and "My School": School Principals in Societies of Control

    ERIC Educational Resources Information Center

    Niesche, Richard

    2015-01-01

    The introduction of new accountabilities and techniques of government for the purposes of educational reform have created new complexities and tensions for school leadership. Policies such as the publishing of league tables in the UK, high stakes testing in the US and the introduction of the "My School" website in Australia are…

  6. Spectroscopy 101: A Practical Introduction to Spectroscopy and Analysis for Undergraduate Organic Chemistry Laboratories

    ERIC Educational Resources Information Center

    Morrill, Lucas A.; Kammeyer, Jacquelin K.; Garg, Neil K.

    2017-01-01

    An undergraduate organic chemistry laboratory that provides an introduction to various spectroscopic techniques is reported. Whereas organic spectroscopy is most often learned and practiced in the context of reaction analyses, this laboratory experiment allows students to become comfortable with [superscript 1]H NMR, [superscript 13]C NMR, and IR…

  7. Development of an automated high-temperature valveless injection system for online gas chromatography

    NASA Astrophysics Data System (ADS)

    Kreisberg, N. M.; Worton, D. R.; Zhao, Y.; Isaacman, G.; Goldstein, A. H.; Hering, S. V.

    2014-12-01

    A reliable method of sample introduction is presented for online gas chromatography with a special application to in situ field portable atmospheric sampling instruments. A traditional multi-port valve is replaced with a valveless sample introduction interface that offers the advantage of long-term reliability and stable sample transfer efficiency. An engineering design model is presented and tested that allows customizing this pressure-switching-based device for other applications. Flow model accuracy is within measurement accuracy (1%) when parameters are tuned for an ambient-pressure detector and 15% accurate when applied to a vacuum-based detector. Laboratory comparisons made between the two methods of sample introduction using a thermal desorption aerosol gas chromatograph (TAG) show that the new interface has approximately 3 times greater reproducibility maintained over the equivalent of a week of continuous sampling. Field performance results for two versions of the valveless interface used in the in situ instrument demonstrate typically less than 2% week-1 response trending and a zero failure rate during field deployments ranging up to 4 weeks of continuous sampling. Extension of the valveless interface to dual collection cells is presented with less than 3% cell-to-cell carryover.

  8. A form of 'parental presence/absence' (PPA) technique for the child patient with dental behaviour management problems.

    PubMed

    Kotsanos, N; Coolidge, T; Velonis, D; Arapostathis, K N

    2009-06-01

    This paper reports on the use of early introduction of a specific parental presence/absence (PPA) behavioural technique to manage the initially uncooperative child. Using a prospective design, 440 healthy children aged 3 to 10 years visited a paediatric dental practice within 33 months. Children exhibiting initially Frankl 'negative' and 'definitely negative' behaviour were empathically offered parental presence only if they were cooperative. Otherwise, the parent stepped out until behaviour improvement. t-tests and Chi-square tests were used to compare characteristics of initially cooperative and uncooperative children, as well as proportions of parents who were asked to leave the surgery. The technique's success was assessed by a one sample binomial test. 75 of the children presented as Frankl either 'negative' (30) or 'definitely negative' (45) at their first visit; 70 (93.3%, p<0.001) responded to the PPA technique by displaying positive behaviour as their first visit progressed. 38 responded without the need to ask the parent to exit the practice room, while the other 32 responded only after their parent exited. 52 children had additional appointments, and 8 required an application of PPA at a second appointment; all children cooperated in all subsequent appointments. Early and empathic application of the PPA technique appears very successful in managing initially uncooperative child patients, suggesting that a randomised controlled trial of the technique is warranted.

  9. CT-guided thermocouple placement for hyperthermia treatment.

    PubMed

    Banerian, K G; Roberts, J L; Borrego, J C; Martinez, A

    1990-05-01

    There is a well-documented synergistic cytotoxic effect when heat is combined with ionizing radiation. An integral component of hyperthermia treatments is the placement of thermocouple probes used for thermal dosimetry. With the surge in interest in the clinical use of hyperthermia, our department is performing an increasing number of thermocouple placements under computed tomographic (CT) guidance. We describe our technique for CT-guided thermocouple placement with two different systems: a trocar introduction system and a peel-away needle introduction system. We discuss the rationale for thermocouple placement, our early experience with this technique, and some potential complications.

  10. A method for introduction of Al2O3 nanofiber into aluminum alloy

    NASA Astrophysics Data System (ADS)

    Chen, Yijin; Qin, He; Kurganova, Y. A.; Gaaze, V. K.

    2018-04-01

    Experimental samples of aluminum matrix composites (AMCs) reinforced with Al2O3 nanofibers were obtained. In order to increase the wettability in liquid phase combination conditions, it is proposed to use copper powder as a carrier of nanofiber. When studying the structure of the samples, a modifying effect of the introduction of reinforcement, demonstrated by grinding the grain, was revealed.

  11. In situ optical measurements for characterization of flame species and remote sensing

    NASA Astrophysics Data System (ADS)

    Cullum, Brian Michael

    1998-12-01

    The following dissertation describes the use of spectroscopic techniques for both characterization of combustion intermediates and remote chemical sensing. The primary techniques that have been used for these measurements include, laser-induced fluorescence (LIF), time resolved LIF, resonance enhanced multiphoton ionization (REMPI) and Raman spectroscopy. A simple and quantitative means of measuring the efficiency of halogenated flame retardants is described, using laser-induced fluorescence (LIF). Intensity based LIF measurements of OH radical have been used to quantitatively measure the efficacy of halogenated flame retardant/polymer plaques. Temporally resolved LIF has been used to determine the extent to which the chemical kinetic theory of flame retardation applies to the effect of these compounds on combustion. We have shown that LIF of OH radicals is a very sensitive means of measuring the efficiency of these flame retardants as well as the giving information about the nature of flame retardation. In addition, we have developed a technique for the introduction of insoluble polymer plaques into a flame for fluorescence analysis. A high power pulsed Nd:YAG laser is used to ablate the sample into the flame while a second pulse from a dye laser is used to measure the LIF of OH radicals. Spectroscopic techniques are also very useful for trace remote analysis of environmental pollutants via optical fibers. A simple fiber-optic probe suitable for remote analysis using resonance enhanced multiphoton ionization (REMPI) has been developed for this purpose and is used to determine the toluene/gasoline concentration in water samples via a headspace measurement. The limit of detection for toluene in water using this probe is 0.54 ppb (wt/wt) with a sample standard deviation of 0.02 ppb (wt/wt). Another technique that has great potential for optical sensing is fluorescence lifetime imaging. A new method for measuring fluorescence lifetime images of quickly decaying species has been developed. This method employs a high powered pulsed laser that excites the fluorescent species in a dual pulse manner, and a non-gated charge coupled device (CCD) for detection of the fluorescence. Unlike other fluorescence lifetime imaging methods, this technique has the potential of monitoring fluorescent species with picosecond lifetimes.

  12. Use of the Keele injector for sample introduction for gas chromatographic analysis of vinclozolin in lettuces.

    PubMed

    Shim, J H; Lee, Y S; Kim, M R; Lee, C J; Kim, I S

    2003-10-10

    We examined a Keele injector for sample introduction for gas chromatographic analysis of vinclozolin treated in lettuces. Samples in milligram quantity were introduced into a glass tube in a Keele injector at a gas chromatograph injection port. The glass tube was then crushed to allow the sample to carry onto a capillary column in a normal manner. The standard calibration curve for quantitative detection of vinclozolin was obtained by determining vinclozolin spiked in samples at variable concentrations. The calibration curve showed a linear response to vinclozolin ranging from 0.05 to 1.0 microg/g, giving a slope value of 174.8, the y-intercept value of -2.8146 and the mean r2-value of 0.9994. Limit of quantification for vinclozolin was 0.05 microg/g by this method, comparable to 0.01 microg/g by a normal injector. When samples treated previously with vinclozolin were determined by the Keele injector, vinclozolin was found to be about 30% lower as compared to a normal method, suggesting about 70% recovery of the spiked vinclozolin by the Keele injector. From these results, the Keele injector was suggested to be potential for sample introduction in gas chromatographic analysis of vinclozolin in lettuce samples.

  13. Incorporating Nonparametric Statistics into Delphi Studies in Library and Information Science

    ERIC Educational Resources Information Center

    Ju, Boryung; Jin, Tao

    2013-01-01

    Introduction: The Delphi technique is widely used in library and information science research. However, many researchers in the field fail to employ standard statistical tests when using this technique. This makes the technique vulnerable to criticisms of its reliability and validity. The general goal of this article is to explore how…

  14. Techniques for Improving Student Writing and Thinking Skills in Text-Heavy Courses.

    ERIC Educational Resources Information Center

    Marra, James L.; And Others

    After an introduction by James L. Marra explaining the Intellectual Heritage Program at the College of Art and Sciences at Temple University (Philadelphia, Pennsylvania), this paper presents four brief faculty essays describing various techniques that the writers use in their classes in the program. The techniques discussed in the paper are…

  15. Computer animation challenges for computational fluid dynamics

    NASA Astrophysics Data System (ADS)

    Vines, Mauricio; Lee, Won-Sook; Mavriplis, Catherine

    2012-07-01

    Computer animation requirements differ from those of traditional computational fluid dynamics (CFD) investigations in that visual plausibility and rapid frame update rates trump physical accuracy. We present an overview of the main techniques for fluid simulation in computer animation, starting with Eulerian grid approaches, the Lattice Boltzmann method, Fourier transform techniques and Lagrangian particle introduction. Adaptive grid methods, precomputation of results for model reduction, parallelisation and computation on graphical processing units (GPUs) are reviewed in the context of accelerating simulation computations for animation. A survey of current specific approaches for the application of these techniques to the simulation of smoke, fire, water, bubbles, mixing, phase change and solid-fluid coupling is also included. Adding plausibility to results through particle introduction, turbulence detail and concentration on regions of interest by level set techniques has elevated the degree of accuracy and realism of recent animations. Basic approaches are described here. Techniques to control the simulation to produce a desired visual effect are also discussed. Finally, some references to rendering techniques and haptic applications are mentioned to provide the reader with a complete picture of the challenges of simulating fluids in computer animation.

  16. Internet Power Searching: The Advanced Manual. 2nd Edition. Neal-Schuman NetGuide Series.

    ERIC Educational Resources Information Center

    Bradley, Phil

    This handbook provides information on how Internet search engines and related software and utilities work and how to use them in order to improve search techniques. The book begins with an introduction to the Internet. Part 1 contains the following chapters that cover mining the Internet for information: "An Introduction to Search…

  17. Physics and Analysis at a Hadron Collider - An Introduction (1/3)

    ScienceCinema

    None

    2018-05-11

    This is the first lecture of three which together discuss the physics of hadron colliders with an emphasis on experimental techniques used for data analysis. This first lecture provides a brief introduction to hadron collider physics and collider detector experiments as well as offers some analysis guidelines. The lectures are aimed at graduate students.

  18. [A system of introduction of the results of scientific research on hygiene into practical health care and national economics].

    PubMed

    Eksler, N D; Vishnevskaia, S S

    1989-01-01

    The country's socio-economic development necessitates further elaboration of new approaches to the introduction of hygienic research results into practice. The main criterion for choosing proper research techniques lies in their economy-type efficiency, both social, medical and economic. A new system of hygienic research introduction should be based on financial and economic stimuli, establishment of a network of inventive firms, as well as supported by an effective mechanisms of information feed-back with due account of health indices.

  19. Simulation of Spiral Slot Antennas on Composite Platforms

    NASA Technical Reports Server (NTRS)

    Volakis, John L.

    1996-01-01

    The project goals, plan and accomplishments up to this point are summarized in the viewgraphs. Among the various accomplishments, the most important have been: the development of the prismatic finite element code for doubly curved platforms and its validation with many different antenna configurations; the design and fabrication of a new slot spiral antennas suitable for automobile cellular, GPS and PCs communications; the investigation and development of various mesh truncation schemes, including the perfectly matched absorber and various fast integral equation methods; and the introduction of a frequency domain extrapolation technique (AWE) for predicting broadband responses using only a few samples of the response. This report contains several individual reports most of which have been submitted for publication to referred journals. For a report on the frequency extrapolation technique, the reader is referred to the UM Radiation Laboratory report A total of 14 papers have been published or accepted for publication with the full or partial support of this grant. Several more papers are in preparation.

  20. Graphical Interface for the Study of Gas-Phase Reaction Kinetics: Cyclopentene Vapor Pyrolysis

    NASA Astrophysics Data System (ADS)

    Marcotte, Ronald E.; Wilson, Lenore D.

    2001-06-01

    The undergraduate laboratory experiment on the pyrolysis of gaseous cyclopentene has been modernized to improve safety, speed, and precision and to better reflect the current practice of physical chemistry. It now utilizes virtual instrument techniques to create a graphical computer interface for the collection and display of experimental data. An electronic pressure gauge has replaced the mercury manometer formerly needed in proximity to the 500 °C pyrolysis oven. Students have much better real-time information available to them and no longer require multiple lab periods to get rate constants and acceptable Arrhenius parameters. The time saved on manual data collection is used to give the students a tour of the computer interfacing hardware and software and a hands-on introduction to gas-phase reagent preparation using a research-grade high-vacuum system. This includes loading the sample, degassing it by the freeze-pump-thaw technique, handling liquid nitrogen and working through the logic necessary for each reconfiguration of the diffusion pump section and the submanifolds.

  1. The diagnostic capability of laser induced fluorescence in the characterization of excised breast tissues

    NASA Astrophysics Data System (ADS)

    Galmed, A. H.; Elshemey, Wael M.

    2017-08-01

    Differentiating between normal, benign and malignant excised breast tissues is one of the major worldwide challenges that need a quantitative, fast and reliable technique in order to avoid personal errors in diagnosis. Laser induced fluorescence (LIF) is a promising technique that has been applied for the characterization of biological tissues including breast tissue. Unfortunately, only few studies have adopted a quantitative approach that can be directly applied for breast tissue characterization. This work provides a quantitative means for such characterization via introduction of several LIF characterization parameters and determining the diagnostic accuracy of each parameter in the differentiation between normal, benign and malignant excised breast tissues. Extensive analysis on 41 lyophilized breast samples using scatter diagrams, cut-off values, diagnostic indices and receiver operating characteristic (ROC) curves, shows that some spectral parameters (peak height and area under the peak) are superior for characterization of normal, benign and malignant breast tissues with high sensitivity (up to 0.91), specificity (up to 0.91) and accuracy ranking (highly accurate).

  2. Evaluation of the matrix effect on gas chromatography--mass spectrometry with carrier gas containing ethylene glycol as an analyte protectant.

    PubMed

    Fujiyoshi, Tomoharu; Ikami, Takahito; Sato, Takashi; Kikukawa, Koji; Kobayashi, Masato; Ito, Hiroshi; Yamamoto, Atsushi

    2016-02-19

    The consequences of matrix effects in GC are a major issue of concern in pesticide residue analysis. The aim of this study was to evaluate the applicability of an analyte protectant generator in pesticide residue analysis using a GC-MS system. The technique is based on continuous introduction of ethylene glycol into the carrier gas. Ethylene glycol as an analyte protectant effectively compensated the matrix effects in agricultural product extracts. All peak intensities were increased by this technique without affecting the GC-MS performance. Calibration curves for ethylene glycol in the GC-MS system with various degrees of pollution were compared and similar response enhancements were observed. This result suggests a convenient multi-residue GC-MS method using an analyte protectant generator instead of the conventional compensation method for matrix-induced response enhancement adding the mixture of analyte protectants into both neat and sample solutions. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. A flexible gas flow reaction cell for in situ x-ray absorption spectroscopy studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kroner, Anna B., E-mail: anna.kroner@diamond.ac.uk; Gilbert, Martin; Duller, Graham

    2016-07-27

    A capillary-based sample environment with hot air blower and integrated gas system was developed at Diamond to conduct X-ray absorption spectroscopy (XAS) studies of materials under time-resolved, in situ conditions. The use of a hot air blower, operating in the temperature range of 298-1173 K, allows introduction of other techniques e.g. X-ray diffraction (XRD), Raman spectroscopy for combined techniques studies. The flexibility to use either quartz or Kapton capillaries allows users to perform XAS measurement at energies as low as 5600 eV. To demonstrate performance, time-resolved, in situ XAS results of Rh catalysts during the process of activation (Rh K-edge,more » Ce L{sub 3}-edge and Cr K-edge) and the study of mixed oxide membrane (La{sub 0.6}Sr{sub 0.4}Co{sub 0.2}Fe{sub 0.8}O{sub 3−δ}) under various partial oxygen pressure conditions are described.« less

  4. User's manual for three dimensional FDTD version D code for scattering from frequency-dependent dielectric and magnetic materials

    NASA Technical Reports Server (NTRS)

    Beggs, John H.; Luebbers, Raymond J.; Kunz, Karl S.

    1992-01-01

    The Penn State Finite Difference Time Domain Electromagnetic Scattering Code version D is a 3-D numerical electromagnetic scattering code based upon the finite difference time domain technique (FDTD). The manual provides a description of the code and corresponding results for several scattering problems. The manual is organized into 14 sections: introduction; description of the FDTD method; operation; resource requirements; version D code capabilities; a brief description of the default scattering geometry; a brief description of each subroutine; a description of the include file; a section briefly discussing Radar Cross Section computations; a section discussing some scattering results; a sample problem setup section; a new problem checklist; references and figure titles. The FDTD technique models transient electromagnetic scattering and interactions with objects of arbitrary shape and/or material composition. In the FDTD method, Maxwell's curl equations are discretized in time-space and all derivatives (temporal and spatial) are approximated by central differences.

  5. Introducing a New Capability at SSRL: Resonant Soft X-ray Scattering

    NASA Astrophysics Data System (ADS)

    Lee, Jun-Sik; Jang, Hoyoung; Lu, Donghui; Kao, Chi-Chang

    Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC recently developed a setup for the resonant soft x-ray scattering (RSXS). In general, the RSXS technique uniquely probes not only structural information, but also chemical specific information. This is because this technique can explore the spatial periodicities of charge, orbital, spin, and lattice with spectroscopic aspect. Moreover, the soft x-ray range is particularly relevant for a study of soft materials as it covers the K-edge of C, N, F, and O, as well as the L-edges of transition metals and M-edges of rare-earth elements. Hence, the RSXS capability has been regarded as a very powerful technique for investigating the intrinsic properties of materials such as quantum- and energy-materials. The RSXS capability at the SSRL composes of in-vacuum 4-circle diffractometer. There are also the fully motorized sample-motion manipulations. Also, the sample can be cooled down to 25 K via the liquid helium. This capability has been installed at BL 13-3, where the photon source is from elliptically polarized undulator (EPU). Covering the photon energies is from 230 eV to 1400 eV. Furthermore, this EPU system offers more degree of freedoms for controlling x-ray polarizations (linear and circular). Using the advance of controlling x-ray polarization, we can also investigate a morphology effect of local domain/grain in materials. The detailed introduction of the RSXS end-station and several results will be touched in this poster presentation.

  6. Marginal accuracy of nickel chromium copings fabricated by conventional and accelerated casting procedures, produced with ringless and metal ring investment procedures: A comparative in vitro study.

    PubMed

    Alex, Deepa; Shetty, Y Bharath; Miranda, Glynis Anita; Prabhu, M Bharath; Karkera, Reshma

    2015-01-01

    Conventional investing and casting techniques are time-consuming and usually requires 2-4 h for completion. Accelerated nonstandard, casting techniques have been reported to achieve similar quality results in significantly less time, namely, in 30-40 min. During casting, it is essential to achieve compensation for the shrinkage of solidifying alloy by investment expansion. The metal casting ring restricts the thermal expansion of investment because the thermal expansion of the ring is lesser than that of the investment. The use of casting ring was challenged with the introduction of the ringless technique. A total of 40 test samples of nickel chromium (Ni-Cr) cast copings were obtained from the patterns fabricated using inlay casting wax. The 20 wax patterns were invested using metal ring and 20 wax patterns were invested using the ringless investment system. Of both the groups, 10 samples underwent conventional casting, and the other 10 underwent accelerated casting. The patterns were casted using the induction casting technique. All the test samples of cast copings were evaluated for vertical marginal gaps at four points on the die employing a stereo optical microscope. The vertical marginal discrepancy data obtained were tabulated. Mean and standard deviations were obtained. Vertical discrepancies were analyzed using analysis of variance and Tukey honestly significantly different. The data obtained were found to be very highly significant (P < 0.001). Mean vertical gap was the maximum for Group II (53.64 μm) followed by Group IV (47.62 μm), Group I (44.83 μm) and Group III (35.35 μm). The Ni-Cr cast copings fabricated with the conventional casting using ringless investment system showed significantly better marginal fit than that of cast copings fabricated from conventional and accelerated casting with metal ring investment and accelerated casting using ringless investment since those copings had shown the least vertical marginal discrepancies among the four methods evaluated in this study.

  7. Accurate and precise determination of isotopic ratios by MC-ICP-MS: a review.

    PubMed

    Yang, Lu

    2009-01-01

    For many decades the accurate and precise determination of isotope ratios has remained a very strong interest to many researchers due to its important applications in earth, environmental, biological, archeological, and medical sciences. Traditionally, thermal ionization mass spectrometry (TIMS) has been the technique of choice for achieving the highest accuracy and precision. However, recent developments in multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) have brought a new dimension to this field. In addition to its simple and robust sample introduction, high sample throughput, and high mass resolution, the flat-topped peaks generated by this technique provide for accurate and precise determination of isotope ratios with precision reaching 0.001%, comparable to that achieved with TIMS. These features, in combination with the ability of the ICP source to ionize nearly all elements in the periodic table, have resulted in an increased use of MC-ICP-MS for such measurements in various sample matrices. To determine accurate and precise isotope ratios with MC-ICP-MS, utmost care must be exercised during sample preparation, optimization of the instrument, and mass bias corrections. Unfortunately, there are inconsistencies and errors evident in many MC-ICP-MS publications, including errors in mass bias correction models. This review examines "state-of-the-art" methodologies presented in the literature for achievement of precise and accurate determinations of isotope ratios by MC-ICP-MS. Some general rules for such accurate and precise measurements are suggested, and calculations of combined uncertainty of the data using a few common mass bias correction models are outlined.

  8. Method and apparatus for pyrolysis--porous layer open tubular column--cryoadsorption headspace sampling and analysis.

    PubMed

    Bruno, Thomas J; Nichols, Jessica E

    2013-04-19

    In previous work, dynamic headspace vapor collection on short, porous layer open tubular (PLOT) capillary columns maintained at low temperature was introduced. In this paper, that metrology is extended with the introduction of a small in situ pyrolysis platform that provides for rapid heating and rapid vapor capture for a wide variety of samples. The new approach is referred to as pyro-PLOT-cryo. The pyrolysis platform is made from two small copper lead wires that hold a basket formed from small diameter, high resistance stainless steel or NiCr wire. The basket is formed to accept a small sample, the mass of which can typically range from 0.2 to 0.05 mg. The pyrolysis is performed by use of a resistor capacitor circuit of the type used in spot welders. We have provided examples of the application of this technique with the analysis of facial cosmetics, plastic explosives, organometallic gasoline additives, polymers, and in micro scale chemical reactions. Additional modifications and future work are also discussed. Published by Elsevier B.V.

  9. Analysis of polar and non-polar VOCs from ambient and source matrices: Development of a new canister autosampler which meets TO-15 QA/QC criteria

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burnett, M.L.W.; Neal, D.; Uchtman, R.

    1997-12-31

    Approximately 108 of the Hazardous Air Pollutants (HAPs) specified in the 1990 Clean Air Act Amendments are classified as volatile organic compounds (VOCs). Of the 108 VOCs, nearly 35% are oxygenated or polar compounds. While more than one sample introduction technique exists for the analysis of these air toxics, SUMMA{reg_sign} canister sampling is suitable for the most complete range of analytes. A broad concentration range of polar and non-polar species can be analyzed from canisters. A new canister autosampler, the Tekmar AUTOCan{trademark} Elite autosampler, has been developed which incorporates the autosampler and concentrator into a single unit. Analysis of polarmore » and non-polar VOCs has been performed. This paper demonstrates adherence to the technical acceptance objectives outlined in the TO-15 methodology including initial calibration, daily calibration, blank analysis, method detection limits and laboratory control samples. The analytical system consists of a Tekmar AUTOCan{trademark} Elite autosampler interfaced to a Hewlett Packard{reg_sign} 5890/5972 MSD.« less

  10. Optimal Inspection of Imports to Prevent Invasive Pest Introduction.

    PubMed

    Chen, Cuicui; Epanchin-Niell, Rebecca S; Haight, Robert G

    2018-03-01

    The United States imports more than 1 billion live plants annually-an important and growing pathway for introduction of damaging nonnative invertebrates and pathogens. Inspection of imports is one safeguard for reducing pest introductions, but capacity constraints limit inspection effort. We develop an optimal sampling strategy to minimize the costs of pest introductions from trade by posing inspection as an acceptance sampling problem that incorporates key features of the decision context, including (i) simultaneous inspection of many heterogeneous lots, (ii) a lot-specific sampling effort, (iii) a budget constraint that limits total inspection effort, (iv) inspection error, and (v) an objective of minimizing cost from accepted defective units. We derive a formula for expected number of accepted infested units (expected slippage) given lot size, sample size, infestation rate, and detection rate, and we formulate and analyze the inspector's optimization problem of allocating a sampling budget among incoming lots to minimize the cost of slippage. We conduct an empirical analysis of live plant inspection, including estimation of plant infestation rates from historical data, and find that inspections optimally target the largest lots with the highest plant infestation rates, leaving some lots unsampled. We also consider that USDA-APHIS, which administers inspections, may want to continue inspecting all lots at a baseline level; we find that allocating any additional capacity, beyond a comprehensive baseline inspection, to the largest lots with the highest infestation rates allows inspectors to meet the dual goals of minimizing the costs of slippage and maintaining baseline sampling without substantial compromise. © 2017 Society for Risk Analysis.

  11. Application of a simple column-switching ion chromatography technique for removal of matrix interferences and sensitive fluorescence determination of acidic compounds (pharmaceutical drugs) in complex samples.

    PubMed

    Muhammad, Nadeem; Subhani, Qamar; Wang, Fenglian; Guo, Dandan; Zhao, Qiming; Wu, Shuchao; Zhu, Yan

    2017-09-15

    This work illustrates the introduction of a simple, rugged and flexible column-switching ion chromatography (IC) technique for an automated on-line QuEChERS extracted samples extracts washing followed by sensitive fluorescence (FLD) determination of five acidic pharmaceutical drugs namely; clofibric acid (CLO), ibuprofen (IBU), aspirin (ASP), naproxen (NAP) and flurobrofen (FLU) in three complex samples (spinach, apple and hospital sewage sludge). An old anion exchange column IonPac ® AS11-HC was utilized as a pre-treatment column for on-line washing of inorganic and organic interferences followed by isocratic separation of five acidic drugs with another anion exchange IonPac ® AS12A analytical column by exploiting the column-switching technique. This novel method exhibited good linearity with correlation coefficients (r 2 ) for all drugs were in the range 0.976-0.996. The limit of detection and quantification of all five acidic drugs were in the range 0.024μg/kg to 8.70μg/kg and 0.082μg/kg to 0.029mg/kg, respectively, and better recoveries in the range 81.17-112.5% with percentage relative standard deviations (RSDs) less than 17.8% were obtained. This on-line sample pre-treatment method showed minimum matrix effect in the range of 0.87-1.25 except for aspirin. This simple rugged and flexible column-switching system required only 28min for maximum elimination of matrices and interferences in three complex samples extracts, isocratic separation of five acidic drugs and for the continuous regeneration of pre-treatment column prior to every subsequent analysis. Finally, this simple automated IC system was appeared so rugged and flexible, which can eliminate and wash out most of interference, impurities and matrices in complex samples, simply by adjusting the NaOH and acetonitrile concentration in washing mobile phase with maximum recoveries of acidic analytes of interest. Copyright © 2017. Published by Elsevier B.V.

  12. Serum and erythrocyte folate status of New Zealand women of childbearing age following a countrywide voluntary programme by the baking industry to fortify bread with folic acid.

    PubMed

    Bradbury, Kathryn E; Williams, Sheila M; Mann, Jim I; Oey, Indrawati; Aitchison, Cindy; Parnell, Winsome; Fleming, Liz; Brown, Rachel C; Skeaff, C Murray

    2016-11-01

    To estimate the folate status of New Zealand women of childbearing age following the introduction, in 2010, of a new voluntary folic acid fortification of bread programme. The 2011 Folate and Women's Health Survey was a cross-sectional survey of women aged 18-44 years carried out in 2011. The survey used a stratified random sampling technique with the Electoral Roll as the sampling frame. Women were asked about consumption of folic-acid-fortified breads and breakfast cereals in a telephone interview. During a clinic visit, blood was collected for serum and erythrocyte folate measurement by microbiological assay. A North Island (Wellington) and South Island (Dunedin) city centre in New Zealand. Two hundred and eighty-eight women, of whom 278 completed a clinic visit. Geometric mean serum and erythrocyte folate concentrations were 30 nmol/l and 996 nmol/l, respectively. Folate status was 30-40 % higher compared with women of childbearing age sampled as part of a national survey in 2008/09, prior to the introduction of the voluntary folic acid bread fortification programme. In the 2011 Folate and Women's Health Survey, reported consumption of fortified bread and fortified breakfast cereal in the past week was associated with 25 % (P=0·01) and 15 % (P=0·04) higher serum folate concentrations, respectively. Serum and erythrocyte folate concentrations have increased in New Zealand women of childbearing age since the number of folic-acid-fortified breads was increased voluntarily in 2010. Consumption of fortified breads and breakfast cereals was associated with a higher folate status.

  13. Development of a Rapid Point-of-Use DNA Test for the Screening of Genuity® Roundup Ready 2 Yield® Soybean in Seed Samples

    PubMed Central

    Chandu, Dilip; Paul, Sudakshina; Parker, Mathew; Dudin, Yelena; King-Sitzes, Jennifer; Perez, Tim; Mittanck, Don W.; Shah, Manali; Glenn, Kevin C.; Piepenburg, Olaf

    2016-01-01

    Testing for the presence of genetically modified material in seed samples is of critical importance for all stakeholders in the agricultural industry, including growers, seed manufacturers, and regulatory bodies. While rapid antibody-based testing for the transgenic protein has fulfilled this need in the past, the introduction of new variants of a given transgene demands new diagnostic regimen that allows distinguishing different traits at the nucleic acid level. Although such molecular tests can be performed by PCR in the laboratory, their requirement for expensive equipment and sophisticated operation have prevented its uptake in point-of-use applications. A recently developed isothermal DNA amplification technique, recombinase polymerase amplification (RPA), combines simple sample preparation and amplification work-flow procedures with the use of minimal detection equipment in real time. Here, we report the development of a highly sensitive and specific RPA-based detection system for Genuity Roundup Ready 2 Yield (RR2Y) material in soybean (Glycine max) seed samples and present the results of studies applying the method in both laboratory and field-type settings. PMID:27314015

  14. Advances in 6d diffraction contrast tomography

    NASA Astrophysics Data System (ADS)

    Viganò, N.; Ludwig, W.

    2018-04-01

    The ability to measure 3D orientation fields and to determine grain boundary character plays a key role in understanding many material science processes, including: crack formation and propagation, grain coarsening, and corrosion processes. X-ray diffraction imaging techniques offer the ability to retrieve such information in a non-destructive manner. Among them, Diffraction Contrast Tomography (DCT) is a monochromatic beam, near-field technique, that uses an extended beam and offers fast mapping of 3D sample volumes. It was previously shown that the six-dimensional extension of DCT can be applied to moderately deformed samples (<= 5% total strain), made from materials that exhibit low levels of elastic deformation of the unit cell (<= 1%). In this article, we improved over the previously proposed 6D-DCT reconstruction method, through the introduction of both a more advanced forward model and reconstruction algorithm. The results obtained with the proposed improvements are compared against the reconstructions previously published in [1], using Electron Backscatter Diffraction (EBSD) measurements as a reference. The result was a noticeably higher quality reconstruction of the grain boundary positions and local orientation fields. The achieved reconstruction quality, together with the low acquisition times, render DCT a valuable tool for the stop-motion study of polycrystalline microstructures, evolving as a function of applied strain or thermal annealing treatments, for selected materials.

  15. Compressed Sensing for Body MRI

    PubMed Central

    Feng, Li; Benkert, Thomas; Block, Kai Tobias; Sodickson, Daniel K; Otazo, Ricardo; Chandarana, Hersh

    2016-01-01

    The introduction of compressed sensing for increasing imaging speed in MRI has raised significant interest among researchers and clinicians, and has initiated a large body of research across multiple clinical applications over the last decade. Compressed sensing aims to reconstruct unaliased images from fewer measurements than that are traditionally required in MRI by exploiting image compressibility or sparsity. Moreover, appropriate combinations of compressed sensing with previously introduced fast imaging approaches, such as parallel imaging, have demonstrated further improved performance. The advent of compressed sensing marks the prelude to a new era of rapid MRI, where the focus of data acquisition has changed from sampling based on the nominal number of voxels and/or frames to sampling based on the desired information content. This paper presents a brief overview of the application of compressed sensing techniques in body MRI, where imaging speed is crucial due to the presence of respiratory motion along with stringent constraints on spatial and temporal resolution. The first section provides an overview of the basic compressed sensing methodology, including the notion of sparsity, incoherence, and non-linear reconstruction. The second section reviews state-of-the-art compressed sensing techniques that have been demonstrated for various clinical body MRI applications. In the final section, the paper discusses current challenges and future opportunities. PMID:27981664

  16. Introduction (PSW-GTR-246)

    Treesearch

    James Halperin; David Ganz

    2013-01-01

    Globally, approximately two-thirds of the world's forests are considered degraded, but practical, cost-effective tools for monitoring forest quality remain elusive. Techniques for monitoring deforestation and changes to forest carbon stocks are widespread and well published. However, techniques for monitoring forest degradation are relatively untested in...

  17. Management Techniques for Librarians.

    ERIC Educational Resources Information Center

    Evans, G. Edward

    This textbook on library management techniques is concerned with basic management problems. Examples of problems in planning, organization, and coordination are drawn from situations in libraries or information centers. After an introduction to library management, the history of management is covered. Several styles of management and organization…

  18. Ruby and sapphire from Jegdalek, Afghanistan

    USGS Publications Warehouse

    Bowersox, G.W.; Foord, E.E.; Laurs, B.M.; Shigley, J.E.; Smith, C.P.

    2000-01-01

    This study provides detailed mining and gemological information on the Jegdalek deposit, in east-central Afghanistan, which is hosted by elongate beds of corundum-bearing marble. Some facet-grade ruby has been recovered, but most of the material consists of semitransparent pink sapphire of cabochon or carving quality. The most common internal features are dense concentrations of healed and nonhealed fracture planes and lamellar twin planes. Color zoning is common, and calcite, apatite, zircon, mica, iron sulfide minerals, graphite, rutile, aluminum hydroxide, and other minerals are also present in some samples. Although the reserves appear to be large, future potential will depend on the establishment of a stable government and the introduction of modern mining and exploration techniques. ?? 2000 Gemological Institute of America.

  19. Introduction to Flight Test Engineering (Introduction aux techniques des essais en vol)

    DTIC Science & Technology

    2005-07-01

    or aircraft parameters • Calculations in the frequency domain ( Fast Fourier Transform) • Data analysis with dedicated software for: • Signal...density Fast Fourier Transform Transfer function analysis Frequency response analysis Etc. PRESENTATION Color/black & white Display screen...envelope by operating the airplane at increasing ranges - representing increasing risk - of engine operation, airspeeds both fast and slow, altitude

  20. DE-CERTS: A Decision Support System for a Comparative Evaluation Method for Risk Management Methodologies and Tools

    DTIC Science & Technology

    1991-09-01

    iv III. THE ANALYTIC HIERARCHY PROCESS ..... ........ 15 A. INTRODUCTION ...... ................. 15 B. THE AHP PROCESS ...... ................ 16 C...INTRODUCTION ...... ................. 26 B. IMPLEMENTATION OF CERTS USING AHP ........ .. 27 1. Consistency ...... ................ 29 2. User Interface...the proposed technique into a Decision Support System. Expert Choice implements the Analytic Hierarchy Process ( AHP ), an approach to multi- criteria

  1. An Introduction to Vortex Breakdown and Vortex Core Bursting (Introduction a la Rupture et a l’Eclatement du Noyau des Vortex).

    DTIC Science & Technology

    1985-03-01

    solved by the use of finite - .- core vortex filament models (Chorin and Bernard, 1973). A recent paper by Stremel (1984) briefly reviewed this...history of vortex sheet numerical modeling and presented a ’state of the art’ numerical technique. Stremel compared his numerical results with experimental

  2. A risk-based predictive tool to prevent accidental introductions of nonindigenous marine species.

    PubMed

    Floerl, Oliver; Inglis, Graeme J; Hayden, Barbara J

    2005-06-01

    Preventing the introduction of nonindigenous species (NIS) is the most efficient way to avoid the costs and impacts of biological invasions. The transport of fouling species on ship hulls is an important vector for the introduction of marine NIS. We use quantitative risk screening techniques to develop a predictive tool of the abundance and variety of organisms being transported by ocean-going yachts. We developed and calibrated an ordinal rank scale of the abundance of fouling assemblages on the hulls of international yacht hulls arriving in New Zealand. Fouling ranks were allocated to 783 international yachts that arrived in New Zealand between 2002 and 2004. Classification tree analysis was used to identify relationships between the fouling ranks and predictor variables that described the maintenance and travel history of the yachts. The fouling ranks provided reliable indications of the actual abundance and variety of fouling assemblages on the yachts and identified most (60%) yachts that had fouling on their hulls. However, classification tree models explained comparatively little of the variation in the distribution of fouling ranks (22.1%), had high misclassification rates (approximately 43%), and low predictive power. In agreement with other studies, the best model selected the age of the toxic antifouling paint on yacht hulls as the principal risk factor for hull fouling. Our study shows that the transport probability of fouling organisms is the result of a complex suite of interacting factors and that large sample sizes will be needed for calibration of robust risk models.

  3. Direct analysis of volatile organic compounds in foods by headspace extraction atmospheric pressure chemical ionisation mass spectrometry.

    PubMed

    Perez-Hurtado, P; Palmer, E; Owen, T; Aldcroft, C; Allen, M H; Jones, J; Creaser, C S; Lindley, M R; Turner, M A; Reynolds, J C

    2017-11-30

    The rapid screening of volatile organic compounds (VOCs) by direct analysis has potential applications in the areas of food and flavour science. Currently, the technique of choice for VOC analysis is gas chromatography/mass spectrometry (GC/MS). However, the long chromatographic run times and elaborate sample preparation associated with this technique have led a movement towards direct analysis techniques, such as selected ion flow tube mass spectrometry (SIFT-MS), proton transfer reaction mass spectrometry (PTR-MS) and electronic noses. The work presented here describes the design and construction of a Venturi jet-pump-based modification for a compact mass spectrometer which enables the direct introduction of volatiles for qualitative and quantitative analysis. Volatile organic compounds were extracted from the headspace of heated vials into the atmospheric pressure chemical ionization source of a quadrupole mass spectrometer using a Venturi pump. Samples were analysed directly with no prior sample preparation. Principal component analysis (PCA) was used to differentiate between different classes of samples. The interface is shown to be able to routinely detect problem analytes such as fatty acids and biogenic amines without the requirement of a derivatisation step, and is shown to be able to discriminate between four different varieties of cheese with good intra and inter-day reproducibility using an unsupervised PCA model. Quantitative analysis is demonstrated using indole standards with limits of detection and quantification of 0.395 μg/mL and 1.316 μg/mL, respectively. The described methodology can routinely detect highly reactive analytes such as volatile fatty acids and diamines without the need for a derivatisation step or lengthy chromatographic separations. The capability of the system was demonstrated by discriminating between different varieties of cheese and monitoring the spoilage of meats. © 2017 The Authors. Rapid Communications in Mass Spectrometry Published by John Wiley & Sons Ltd.

  4. Direct analysis of volatile organic compounds in foods by headspace extraction atmospheric pressure chemical ionisation mass spectrometry

    PubMed Central

    Perez‐Hurtado, P.; Palmer, E.; Owen, T.; Aldcroft, C.; Allen, M.H.; Jones, J.; Creaser, C.S.; Lindley, M.R.; Turner, M.A.

    2017-01-01

    Rationale The rapid screening of volatile organic compounds (VOCs) by direct analysis has potential applications in the areas of food and flavour science. Currently, the technique of choice for VOC analysis is gas chromatography/mass spectrometry (GC/MS). However, the long chromatographic run times and elaborate sample preparation associated with this technique have led a movement towards direct analysis techniques, such as selected ion flow tube mass spectrometry (SIFT‐MS), proton transfer reaction mass spectrometry (PTR‐MS) and electronic noses. The work presented here describes the design and construction of a Venturi jet‐pump‐based modification for a compact mass spectrometer which enables the direct introduction of volatiles for qualitative and quantitative analysis. Methods Volatile organic compounds were extracted from the headspace of heated vials into the atmospheric pressure chemical ionization source of a quadrupole mass spectrometer using a Venturi pump. Samples were analysed directly with no prior sample preparation. Principal component analysis (PCA) was used to differentiate between different classes of samples. Results The interface is shown to be able to routinely detect problem analytes such as fatty acids and biogenic amines without the requirement of a derivatisation step, and is shown to be able to discriminate between four different varieties of cheese with good intra and inter‐day reproducibility using an unsupervised PCA model. Quantitative analysis is demonstrated using indole standards with limits of detection and quantification of 0.395 μg/mL and 1.316 μg/mL, respectively. Conclusions The described methodology can routinely detect highly reactive analytes such as volatile fatty acids and diamines without the need for a derivatisation step or lengthy chromatographic separations. The capability of the system was demonstrated by discriminating between different varieties of cheese and monitoring the spoilage of meats. PMID:28857369

  5. Gas emission from the UO2 samples, containing fission products and burnable absorber

    NASA Astrophysics Data System (ADS)

    Kopytin, V. P.; Baranov, V. G.; Burlakova, M. A.; Tenishev, A. V.; Kuzmin, R. S.; Pokrovskiy, S. A.; Mikhalchik, V. V.

    2016-04-01

    The process gas released from the fuel pellets of uranium fuel during fuel burn-up reduces the thermal conductivity of the rod-shell gap, enhances hydrogen embrittlement of the cladding material, causes it's carbonization, as well as transport processes in the fuel. In this study a technique of investigating the thermal desorption of gases from the UO2 fuel material were perfected in the temperature range 300-2000 K for uniform sample heating rate of 15 K/min in vacuum. The characteristic kinetic dependences are acquired for the gas emission from UO2 samples, containing simulators of fission products (SFP) and the burnable neutron absorber (BNA). Depending on the amount of SFP and BNA contained in the sample thermal desorption gas spectra (TDGS) vary. The composition of emitted gas varies, as well as the number of peaks in the TDGS and the peaks shift to higher temperatures. This indicates that introduction of SFPs and BNA alters the sample material structure and cause the creation of so- called traps which have different bonding energies to the gases. The traps can be a grid of dislocations, voids, and contained in the UO2 matrix SFP and BNA. Similar processes will occur in the fuel pellets in the real conditions of the Nuclear Power Plant as well.

  6. Infrared micro-spectral imaging: distinction of tissue types in axillary lymph node histology

    PubMed Central

    Bird, Benjamin; Miljkovic, Milos; Romeo, Melissa J; Smith, Jennifer; Stone, Nicholas; George, Michael W; Diem, Max

    2008-01-01

    Background Histopathologic evaluation of surgical specimens is a well established technique for disease identification, and has remained relatively unchanged since its clinical introduction. Although it is essential for clinical investigation, histopathologic identification of tissues remains a time consuming and subjective technique, with unsatisfactory levels of inter- and intra-observer discrepancy. A novel approach for histological recognition is to use Fourier Transform Infrared (FT-IR) micro-spectroscopy. This non-destructive optical technique can provide a rapid measurement of sample biochemistry and identify variations that occur between healthy and diseased tissues. The advantage of this method is that it is objective and provides reproducible diagnosis, independent of fatigue, experience and inter-observer variability. Methods We report a method for analysing excised lymph nodes that is based on spectral pathology. In spectral pathology, an unstained (fixed or snap frozen) tissue section is interrogated by a beam of infrared light that samples pixels of 25 μm × 25 μm in size. This beam is rastered over the sample, and up to 100,000 complete infrared spectra are acquired for a given tissue sample. These spectra are subsequently analysed by a diagnostic computer algorithm that is trained by correlating spectral and histopathological features. Results We illustrate the ability of infrared micro-spectral imaging, coupled with completely unsupervised methods of multivariate statistical analysis, to accurately reproduce the histological architecture of axillary lymph nodes. By correlating spectral and histopathological features, a diagnostic algorithm was trained that allowed both accurate and rapid classification of benign and malignant tissues composed within different lymph nodes. This approach was successfully applied to both deparaffinised and frozen tissues and indicates that both intra-operative and more conventional surgical specimens can be diagnosed by this technique. Conclusion This paper provides strong evidence that automated diagnosis by means of infrared micro-spectral imaging is possible. Recent investigations within the author's laboratory upon lymph nodes have also revealed that cancers from different primary tumours provide distinctly different spectral signatures. Thus poorly differentiated and hard-to-determine cases of metastatic invasion, such as micrometastases, may additionally be identified by this technique. Finally, we differentiate benign and malignant tissues composed within axillary lymph nodes by completely automated methods of spectral analysis. PMID:18759967

  7. Membrane Introduction Mass Spectrometry Combined with an Orthogonal Partial-Least Squares Calibration Model for Mixture Analysis.

    PubMed

    Li, Min; Zhang, Lu; Yao, Xiaolong; Jiang, Xingyu

    2017-01-01

    The emerging membrane introduction mass spectrometry technique has been successfully used to detect benzene, toluene, ethyl benzene and xylene (BTEX), while overlapped spectra have unfortunately hindered its further application to the analysis of mixtures. Multivariate calibration, an efficient method to analyze mixtures, has been widely applied. In this paper, we compared univariate and multivariate analyses for quantification of the individual components of mixture samples. The results showed that the univariate analysis creates poor models with regression coefficients of 0.912, 0.867, 0.440 and 0.351 for BTEX, respectively. For multivariate analysis, a comparison to the partial-least squares (PLS) model shows that the orthogonal partial-least squares (OPLS) regression exhibits an optimal performance with regression coefficients of 0.995, 0.999, 0.980 and 0.976, favorable calibration parameters (RMSEC and RMSECV) and a favorable validation parameter (RMSEP). Furthermore, the OPLS exhibits a good recovery of 73.86 - 122.20% and relative standard deviation (RSD) of the repeatability of 1.14 - 4.87%. Thus, MIMS coupled with the OPLS regression provides an optimal approach for a quantitative BTEX mixture analysis in monitoring and predicting water pollution.

  8. Models of Purposive Human Organization: A Comparative Study

    DTIC Science & Technology

    1984-02-01

    develop techniques for organizational diagnosis with the D-M model, to be followed by intervention by S-T methodology. 2. Introduction 2.1. Background In...relational and object data for Dinnat-Murphree model construction. 2. Develop techniques for organizational diagnosis with the Dinnat-Murphree model

  9. Purification of pharmaceutical preparations using thin-layer chromatography to obtain mass spectra with Direct Analysis in Real Time and accurate mass spectrometry.

    PubMed

    Wood, Jessica L; Steiner, Robert R

    2011-06-01

    Forensic analysis of pharmaceutical preparations requires a comparative analysis with a standard of the suspected drug in order to identify the active ingredient. Purchasing analytical standards can be expensive or unattainable from the drug manufacturers. Direct Analysis in Real Time (DART™) is a novel, ambient ionization technique, typically coupled with a JEOL AccuTOF™ (accurate mass) mass spectrometer. While a fast and easy technique to perform, a drawback of using DART™ is the lack of component separation of mixtures prior to ionization. Various in-house pharmaceutical preparations were purified using thin-layer chromatography (TLC) and mass spectra were subsequently obtained using the AccuTOF™- DART™ technique. Utilizing TLC prior to sample introduction provides a simple, low-cost solution to acquiring mass spectra of the purified preparation. Each spectrum was compared against an in-house molecular formula list to confirm the accurate mass elemental compositions. Spectra of purified ingredients of known pharmaceuticals were added to an in-house library for use as comparators for casework samples. Resolving isomers from one another can be accomplished using collision-induced dissociation after ionization. Challenges arose when the pharmaceutical preparation required an optimized TLC solvent to achieve proper separation and purity of the standard. Purified spectra were obtained for 91 preparations and included in an in-house drug standard library. Primary standards would only need to be purchased when pharmaceutical preparations not previously encountered are submitted for comparative analysis. TLC prior to DART™ analysis demonstrates a time efficient and cost saving technique for the forensic drug analysis community. Copyright © 2011 John Wiley & Sons, Ltd. Copyright © 2011 John Wiley & Sons, Ltd.

  10. A novel process for introducing a new intraoperative program: a multidisciplinary paradigm for mitigating hazards and improving patient safety.

    PubMed

    Rodriguez-Paz, Jose M; Mark, Lynette J; Herzer, Kurt R; Michelson, James D; Grogan, Kelly L; Herman, Joseph; Hunt, David; Wardlow, Linda; Armour, Elwood P; Pronovost, Peter J

    2009-01-01

    Since the Institute of Medicine's report, To Err is Human, was published, numerous interventions have been designed and implemented to correct the defects that lead to medical errors and adverse events; however, most efforts were largely reactive. Safety, communication, team performance, and efficiency are areas of care that attract a great deal of attention, especially regarding the introduction of new technologies, techniques, and procedures. We describe a multidisciplinary process that was implemented at our hospital to identify and mitigate hazards before the introduction of a new technique: high-dose-rate intraoperative radiation therapy, (HDR-IORT). A multidisciplinary team of surgeons, anesthesiologists, radiation oncologists, physicists, nurses, hospital risk managers, and equipment specialists used a structured process that included in situ clinical simulation to uncover concerns among care providers and to prospectively identify and mitigate defects for patients who would undergo surgery using the HDR-IORT technique. We identified and corrected 20 defects in the simulated patient care process before application to actual patients. Subsequently, eight patients underwent surgery using the HDR-IORT technique with no recurrence of simulation-identified or unanticipated defects. Multiple benefits were derived from the use of this systematic process to introduce the HDR-IORT technique; namely, the safety and efficiency of care for this select patient population was optimized, and this process mitigated harmful or adverse events before the inclusion of actual patients. Further work is needed, but the process outlined in this paper can be universally applied to the introduction of any new technologies, treatments, or procedures.

  11. The use of mass spectrometry to analyze dried blood spots.

    PubMed

    Wagner, Michel; Tonoli, David; Varesio, Emmanuel; Hopfgartner, Gérard

    2016-01-01

    Dried blood spots (DBS) typically consist in the deposition of small volumes of capillary blood onto dedicated paper cards. Comparatively to whole blood or plasma samples, their benefits rely in the fact that sample collection is easier and that logistic aspects related to sample storage and shipment can be relatively limited, respectively, without the need of a refrigerator or dry ice. Originally, this approach has been developed in the sixties to support the analysis of phenylalanine for the detection of phenylketonuria in newborns using bacterial inhibition test. In the nineties tandem mass spectrometry was established as the detection technique for phenylalanine and tyrosine. DBS became rapidly recognized for their clinical value: they were widely implemented in pediatric settings with mass spectrometric detection, and were closely associated to the debut of newborn screening (NBS) programs, as a part of public health policies. Since then, sample collection on paper cards has been explored with various analytical techniques in other areas more or less successfully regarding large-scale applications. Moreover, in the last 5 years a regain of interest for DBS was observed and originated from the bioanalytical community to support drug development (e.g., PK studies) or therapeutic drug monitoring mainly. Those recent applications were essentially driven by improved sensitivity of triple quadrupole mass spectrometers. This review presents an overall view of all instrumental and methodological developments for DBS analysis with mass spectrometric detection, with and without separation techniques. A general introduction to DBS will describe their advantages and historical aspects of their emergence. A second section will focus on blood collection, with a strong emphasis on specific parameters that can impact quantitative analysis, including chromatographic effects, hematocrit effects, blood effects, and analyte stability. A third part of the review is dedicated to sample preparation and will consider off-line and on-line extractions; in particular, instrumental designs that have been developed so far for DBS extraction will be detailed. Flow injection analysis and applications will be discussed in section IV. The application of surface analysis mass spectrometry (DESI, paper spray, DART, APTDCI, MALDI, LDTD-APCI, and ICP) to DBS is described in section V, while applications based on separation techniques (e.g., liquid or gas chromatography) are presented in section VI. To conclude this review, the current status of DBS analysis is summarized, and future perspectives are provided. © 2014 Wiley Periodicals, Inc.

  12. Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications

    PubMed Central

    Lourenço, Célia; Turner, Claire

    2014-01-01

    Breath analysis is a promising field with great potential for non-invasive diagnosis of a number of disease states. Analysis of the concentrations of volatile organic compounds (VOCs) in breath with an acceptable accuracy are assessed by means of using analytical techniques with high sensitivity, accuracy, precision, low response time, and low detection limit, which are desirable characteristics for the detection of VOCs in human breath. “Breath fingerprinting”, indicative of a specific clinical status, relies on the use of multivariate statistics methods with powerful in-built algorithms. The need for standardisation of sample collection and analysis is the main issue concerning breath analysis, blocking the introduction of breath tests into clinical practice. This review describes recent scientific developments in basic research and clinical applications, namely issues concerning sampling and biochemistry, highlighting the diagnostic potential of breath analysis for disease diagnosis. Several considerations that need to be taken into account in breath analysis are documented here, including the growing need for metabolomics to deal with breath profiles. PMID:24957037

  13. Breath analysis in disease diagnosis: methodological considerations and applications.

    PubMed

    Lourenço, Célia; Turner, Claire

    2014-06-20

    Breath analysis is a promising field with great potential for non-invasive diagnosis of a number of disease states. Analysis of the concentrations of volatile organic compounds (VOCs) in breath with an acceptable accuracy are assessed by means of using analytical techniques with high sensitivity, accuracy, precision, low response time, and low detection limit, which are desirable characteristics for the detection of VOCs in human breath. "Breath fingerprinting", indicative of a specific clinical status, relies on the use of multivariate statistics methods with powerful in-built algorithms. The need for standardisation of sample collection and analysis is the main issue concerning breath analysis, blocking the introduction of breath tests into clinical practice. This review describes recent scientific developments in basic research and clinical applications, namely issues concerning sampling and biochemistry, highlighting the diagnostic potential of breath analysis for disease diagnosis. Several considerations that need to be taken into account in breath analysis are documented here, including the growing need for metabolomics to deal with breath profiles.

  14. Antibacterial performance of nano polypropylene filter media containing nano-TiO2 and clay particles

    NASA Astrophysics Data System (ADS)

    Shafiee, Sara; Zarrebini, Mohammad; Naghashzargar, Elham; Semnani, Dariush

    2015-10-01

    Disinfection and elimination of pathogenic microorganisms from liquid can be achieved by filtration process using antibacterial filter media. The advent of nanotechnology has facilitated the introduction of membranes consisting of nano-fiber in filtration operations. The melt electro-spun fibers due to their extremely small diameters are used in the production of this particular filtration medium. In this work, antibacterial polypropylene filter medium containing clay particles and nano-TiO2 were made using melt electro-spun technology. Antibacterial performance of polypropylene nano-filters was evaluated using E. coli bacteria. Additionally, filtration efficiency of the samples in terms fiber diameter, filter porosity, and fiber distribution using image processing technique was determined. Air permeability and dust aerosol tests were conducted to establish the suitability of the samples as a filter medium. It was concluded that as far as antibacterial property is concerned, nano-fibers filter media containing clay particles are preferential to similar media containing TiO2 nanoparticles.

  15. Towards real-time metabolic profiling of a biopsy specimen during a surgical operation by 1H high resolution magic angle spinning nuclear magnetic resonance: a case report

    PubMed Central

    2012-01-01

    Introduction Providing information on cancerous tissue samples during a surgical operation can help surgeons delineate the limits of a tumoral invasion more reliably. Here, we describe the use of metabolic profiling of a colon biopsy specimen by high resolution magic angle spinning nuclear magnetic resonance spectroscopy to evaluate tumoral invasion during a simulated surgical operation. Case presentation Biopsy specimens (n = 9) originating from the excised right colon of a 66-year-old Caucasian women with an adenocarcinoma were automatically analyzed using a previously built statistical model. Conclusions Metabolic profiling results were in full agreement with those of a histopathological analysis. The time-response of the technique is sufficiently fast for it to be used effectively during a real operation (17 min/sample). Metabolic profiling has the potential to become a method to rapidly characterize cancerous biopsies in the operation theater. PMID:22257563

  16. The effect of bismuth on the structure, magnetic and electric properties of Co2MnO4 spinel multiferroic

    NASA Astrophysics Data System (ADS)

    Chouaya, H.; Smari, M.; Walha, I.; Dhahri, E.; Graça, M. P. F.; Valente, M. A.

    2018-04-01

    Mixed Co2Mn1-xBixO4 (x = 0, x = 0.05 and x = 0.1) samples were prepared by the sol-gel method using the citric acid route and characterized by various techniques. The X-ray diffraction (XRD) and Raman spectroscopic analyses confirmed the formation of inverse spinel cubic structure with Fd 3 ‾ m space group. The introduction of Bismuth (Bi) into Co2MnO4 did not modify the ferrimagnetic character of the parent compound Co2MnO4, whereas the field-cooled magnetizations MFC and the Curie temperature Tc decreased when increasing the Bi content. The electrical properties showed an activation energy (Ea) increase caused by the decrease of the double-exchange interaction following the substitution of Mn3+ by Bi3+. Eventually, the temperature coefficient of resistance (TCR) shows significant values for all samples can be investigated also as good candidates for bolometer applications.

  17. Thermally-actuated, phase change flow control for microfluidic systems.

    PubMed

    Chen, Zongyuan; Wang, Jing; Qian, Shizhi; Bau, Haim H

    2005-11-01

    An easy to implement, thermally-actuated, noninvasive method for flow control in microfluidic devices is described. This technique takes advantage of the phase change of the working liquid itself-the freezing and melting of a portion of a liquid slug-to noninvasively close and open flow passages (referred to as a phase change valve). The valve was designed for use in a miniature diagnostic system for detecting pathogens in oral fluids at the point of care. The paper describes the modeling, construction, and characteristics of the valve. The experimental results favorably agree with theoretical predictions. In addition, the paper demonstrates the use of the phase change valves for flow control, sample metering and distribution into multiple analysis paths, sealing of a polymerase chain reaction (PCR) chamber, and sample introduction into and withdrawal from a closed loop. The phase change valve is electronically addressable, does not require any moving parts, introduces only minimal dead volume, is leakage and contamination free, and is biocompatible.

  18. Applications of Single-Cell Sequencing for Multiomics.

    PubMed

    Xu, Yungang; Zhou, Xiaobo

    2018-01-01

    Single-cell sequencing interrogates the sequence or chromatin information from individual cells with advanced next-generation sequencing technologies. It provides a higher resolution of cellular differences and a better understanding of the underlying genetic and epigenetic mechanisms of an individual cell in the context of its survival and adaptation to microenvironment. However, it is more challenging to perform single-cell sequencing and downstream data analysis, owing to the minimal amount of starting materials, sample loss, and contamination. In addition, due to the picogram level of the amount of nucleic acids used, heavy amplification is often needed during sample preparation of single-cell sequencing, resulting in the uneven coverage, noise, and inaccurate quantification of sequencing data. All these unique properties raise challenges in and thus high demands for computational methods that specifically fit single-cell sequencing data. We here comprehensively survey the current strategies and challenges for multiple single-cell sequencing, including single-cell transcriptome, genome, and epigenome, beginning with a brief introduction to multiple sequencing techniques for single cells.

  19. Towards an optimal flow: Density-of-states-informed replica-exchange simulations

    DOE PAGES

    Vogel, Thomas; Perez, Danny

    2015-11-05

    Here we learn that replica exchange (RE) is one of the most popular enhanced-sampling simulations technique in use today. Despite widespread successes, RE simulations can sometimes fail to converge in practical amounts of time, e.g., when sampling around phase transitions, or when a few hard-to-find configurations dominate the statistical averages. We introduce a generalized RE scheme, density-of-states-informed RE, that addresses some of these challenges. The key feature of our approach is to inform the simulation with readily available, but commonly unused, information on the density of states of the system as the RE simulation proceeds. This enables two improvements, namely,more » the introduction of resampling moves that actively move the system towards equilibrium and the continual adaptation of the optimal temperature set. As a consequence of these two innovations, we show that the configuration flow in temperature space is optimized and that the overall convergence of RE simulations can be dramatically accelerated.« less

  20. Hydrodynamic injection with pneumatic valving for microchip electrophoresis with total analyte utilization

    PubMed Central

    Sun, Xuefei; Kelly, Ryan T.; Danielson, William F.; Agrawal, Nitin; Tang, Keqi; Smith, Richard D.

    2011-01-01

    A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip capillary electrophoresis (CE) separations. The poly(dimethylsiloxane) (PDMS) devices used for evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersection geometry, the solution back pressure and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to >2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4 cm long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, little sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations, for multiplexing CE separations and for sample-limited bioanalyses are discussed. PMID:21520147

  1. Introduction to total- and partial-pressure measurements in vacuum systems

    NASA Technical Reports Server (NTRS)

    Outlaw, R. A.; Kern, F. A.

    1989-01-01

    An introduction to the fundamentals of total and partial pressure measurement in the vacuum regime (760 x 10 to the -16th power Torr) is presented. The instrument most often used in scientific fields requiring vacuum measurement are discussed with special emphasis on ionization type gauges and quadrupole mass spectrometers. Some attention is also given to potential errors in measurement as well as calibration techniques.

  2. An Introduction to Benefit-Cost Analysis for Evaluating Public Expenditure Alternatives. Learning Packages in the Policy Sciences, PS-22.

    ERIC Educational Resources Information Center

    LaPlante, Josephine M.; Durham, Taylor R.

    A revised edition of PS-14, "An Introduction to Benefit-Cost Analysis for Evaluating Public Programs," presents concepts and techniques of benefit-cost analysis as tools that can be used to assist in deciding between alternatives. The goals of the new edition include teaching students to think about the possible benefits and costs of each…

  3. 76 FR 13242 - Change in Postal Prices

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-10

    [email protected] (electronic filing assistance). SUPPLEMENTARY INFORMATION: Table of Contents I. Introduction II. Notice of Filings III. Ordering Paragraphs I. Introduction On March 1, 2011, the Commission... Postal Service-branded parcel box designed to contain product samples and other advertising material from...

  4. Greeks Assisting Greeks (G.A.G). Training Manual.

    ERIC Educational Resources Information Center

    Ensminger, David

    This training manual, intended for use by college students to learn peer counseling techniques, contains four sections. The first section provides an introduction to peer counseling. Effective therapeutic communication, solving a problem, basic counseling techniques, communicating styles, and the limitations of peer counseling are discussed. The…

  5. Active control of large space structures: An introduction and overview

    NASA Technical Reports Server (NTRS)

    Doane, G. B., III; Tollison, D. K.; Waites, H. B.

    1985-01-01

    An overview of the large space structure (LSS) control system design problem is presented. The LSS is defined as a class of system, and LSS modeling techniques are discussed. Model truncation, control system objectives, current control law design techniques, and particular problem areas are discussed.

  6. Music: Instrumental Techniques, Conducting.

    ERIC Educational Resources Information Center

    Grozan, Carl

    A course in introduction to the conducting of music groups of voices or instruments is presented. The approach used is a laboratory approach in which pupils will develop skills in score reading, physical gestures, rehearsal techniques, transpositions, voice and instrument ranges. Course objectives include: (1) The pupil will identify all…

  7. An Introduction to Modern Missing Data Analyses

    ERIC Educational Resources Information Center

    Baraldi, Amanda N.; Enders, Craig K.

    2010-01-01

    A great deal of recent methodological research has focused on two modern missing data analysis methods: maximum likelihood and multiple imputation. These approaches are advantageous to traditional techniques (e.g. deletion and mean imputation techniques) because they require less stringent assumptions and mitigate the pitfalls of traditional…

  8. Unlocking hidden genomic sequence

    PubMed Central

    Keith, Jonathan M.; Cochran, Duncan A. E.; Lala, Gita H.; Adams, Peter; Bryant, Darryn; Mitchelson, Keith R.

    2004-01-01

    Despite the success of conventional Sanger sequencing, significant regions of many genomes still present major obstacles to sequencing. Here we propose a novel approach with the potential to alleviate a wide range of sequencing difficulties. The technique involves extracting target DNA sequence from variants generated by introduction of random mutations. The introduction of mutations does not destroy original sequence information, but distributes it amongst multiple variants. Some of these variants lack problematic features of the target and are more amenable to conventional sequencing. The technique has been successfully demonstrated with mutation levels up to an average 18% base substitution and has been used to read previously intractable poly(A), AT-rich and GC-rich motifs. PMID:14973330

  9. Electrothermal vaporization of mineral acid solutions in inductively coupled plasma mass spectrometry: comparison with sample nebulization

    NASA Astrophysics Data System (ADS)

    Mora, Juan; Gras, Luis; van Veen, Eric H.; de Loos-Vollebregt, Margaretha T. C.

    1999-06-01

    The analytical behaviour of an electrothermal vaporization (ETV) device for the introduction of mineral acid solutions in inductively coupled plasma mass spectrometry (ICP-MS) was evaluated. Water, nitric acid, hydrochloric acid, perchloric acid and sulphuric acid in concentrations within the 0.05-1.0 mol l-1 range were studied. For all the acids tested, increasing the acid concentration increases the ion signal and deteriorates the precision. The magnitude of the signal enhancement depends on the analyte and on the acid considered. Acid solutions give rise to ion signals that are between 2 and 10 times higher than those with water. Among the acids tested, sulphuric acid provides the highest signals. The addition of palladium reduces matrix effects due to the acids and increases the signal in ETV ICP-MS. In comparison with conventional sample nebulization (CS), the ETV sample introduction system provides higher sensitivities (between 2 and 20 times higher) at the same acid concentration. The magnitude of this improvement is similar to that obtained with a microwave desolvation system (MWDS). The ETV sample introduction system gives rise to the lowest background signals from matrix-induced species. Due to this fact, the limits of detection (LODs) obtained for the isotopes affected by any interference are lower for ETV sample introduction than those obtained with the CS and the MWDS. For the isotopes that do not suffer from matrix-induced spectral interferences, the ETV gives rise to LODs higher than those obtained with the CS. For these isotopes the lowest LODs are obtained with MWDS.

  10. Short torch design for direct liquid sample introduction using conventional and micro-nebulizers for plasma spectrometry

    DOEpatents

    Montaser, Akbar [Potomac, MD; Westphal, Craig S [Landenberg, PA; Kahen, Kaveh [Montgomery Village, MD; Rutkowski, William F [Arlington, VA

    2008-01-08

    An apparatus and method for providing direct liquid sample introduction using a nebulizer are provided. The apparatus and method include a short torch having an inner tube and an outer tube, and an elongated adapter having a cavity for receiving the nebulizer and positioning a nozzle tip of the nebulizer a predetermined distance from a tip of the outer tube of the short torch. The predetermined distance is preferably about 2-5 mm.

  11. The Chemistry of Paper Preservation: Part 1. The Aging of Paper and Conservation Techniques

    NASA Astrophysics Data System (ADS)

    Carter, Henry A.

    1996-05-01

    This study provides an introduction to the problem of the aging of paper and the conservation techniques that are currently being employed in paper preservation. The chemical reactions that are responsible for the aging of paper are discussed with the conclusion that acid-catalyzed hydrolysis is the predominant mechanism for cellulose degradation and strength loss. A description and the chemistry of a number of mass deacidification methods are presented. The more viable deacidification methods include the DEZ, Wei T'o, FMC, Bookkeeper, Viennese, Book Preservation Associates, Sable and the Batelle processes. A summary of the literature on the evaluations of these processes is presented, and the benefits and limitations of the mass deacidification methods are discussed. Other conservation techniques such as paper strengthening, conservation bleaching, and pest control are briefly introduced, followed by an introduction to alkaline papermaking.

  12. Introduction to Acoustics

    NASA Astrophysics Data System (ADS)

    Rossing, Thomas

    This brief introduction may help to persuade the reader that acoustics covers a wide range of interesting topics. It is impossible to cover all these topics in a single handbook, but we have attempted to include a sampling of hot topics that represent current acoustical research, both fundamental and applied.

  13. Estimating the rate of biological introductions: Lessepsian fishes in the Mediterranean.

    PubMed

    Belmaker, Jonathan; Brokovich, Eran; China, Victor; Golani, Daniel; Kiflawi, Moshe

    2009-04-01

    Sampling issues preclude the direct use of the discovery rate of exotic species as a robust estimate of their rate of introduction. Recently, a method was advanced that allows maximum-likelihood estimation of both the observational probability and the introduction rate from the discovery record. Here, we propose an alternative approach that utilizes the discovery record of native species to control for sampling effort. Implemented in a Bayesian framework using Markov chain Monte Carlo simulations, the approach provides estimates of the rate of introduction of the exotic species, and of additional parameters such as the size of the species pool from which they are drawn. We illustrate the approach using Red Sea fishes recorded in the eastern Mediterranean, after crossing the Suez Canal, and show that the two approaches may lead to different conclusions. The analytical framework is highly flexible and could provide a basis for easy modification to other systems for which first-sighting data on native and introduced species are available.

  14. Stress Management for Children and Adolescents.

    ERIC Educational Resources Information Center

    Sensor, M. Carol

    This handbook was designed to provide a basic introduction to and understanding of stress and its impact upon children. Several coping techniques for children are presented along with the methods with which to teach them. These techniques are intended to provide a resource for school psychologists working with children and adolescents who are…

  15. Introduction to the JASIST Special Topic Issue on Web Retrieval and Mining: A Machine Learning Perspective.

    ERIC Educational Resources Information Center

    Chen, Hsinchun

    2003-01-01

    Discusses information retrieval techniques used on the World Wide Web. Topics include machine learning in information extraction; relevance feedback; information filtering and recommendation; text classification and text clustering; Web mining, based on data mining techniques; hyperlink structure; and Web size. (LRW)

  16. Asking the Right Questions: Techniques for Collaboration and School Change. 2nd Edition.

    ERIC Educational Resources Information Center

    Holcomb, Edie L.

    This work provides school change leaders with tools, techniques, tips, examples, illustrations, and stories about promoting school change. Tools provided include histograms, surveys, run charts, weighted voting, force-field analysis, decision matrices, and many others. Chapter 1, "Introduction," applies a matrix for asking questions…

  17. Assessment of Techniques for Evaluating Computer Systems for Federal Agency Procurements. Final Report.

    ERIC Educational Resources Information Center

    Letmanyi, Helen

    Developed to identify and qualitatively assess computer system evaluation techniques for use during acquisition of general purpose computer systems, this document presents several criteria for comparison and selection. An introduction discusses the automatic data processing (ADP) acquisition process and the need to plan for uncertainty through…

  18. A Simple Photochemical Experiment for the Advanced Laboratory.

    ERIC Educational Resources Information Center

    Rosenfeld, Stuart M.

    1986-01-01

    Describes an experiment to provide students with: (1) an introduction to photochemical techniques and theory; (2) an experience with semimicro techniques; (3) an application of carbon-14 nuclear magnetic resonance; and (4) a laboratory with some qualities of a genuine experiment. These criteria are met in the photooxidation of 9,…

  19. Dynamic Programming: An Introduction by Example

    ERIC Educational Resources Information Center

    Zietz, Joachim

    2007-01-01

    The author introduces some basic dynamic programming techniques, using examples, with the help of the computer algebra system "Maple". The emphasis is on building confidence and intuition for the solution of dynamic problems in economics. To integrate the material better, the same examples are used to introduce different techniques. One covers the…

  20. Michigan Physicians' Conference on Elder Abuse. Final Report.

    ERIC Educational Resources Information Center

    Sengstock, Mary C.; O'Brien, James G.

    The final report describes the Michigan Physicians' Conference on Elder Abuse project. The project conference had four major content areas, including: a general introduction to the problem of elder abuse; clinical symptoms of abuse; legal issues; and referral and case management techniques. Training techniques included lectures, group discussion,…

  1. Adaptive Educational Software by Applying Reinforcement Learning

    ERIC Educational Resources Information Center

    Bennane, Abdellah

    2013-01-01

    The introduction of the intelligence in teaching software is the object of this paper. In software elaboration process, one uses some learning techniques in order to adapt the teaching software to characteristics of student. Generally, one uses the artificial intelligence techniques like reinforcement learning, Bayesian network in order to adapt…

  2. A Practical Introduction to Separation and Purification Techniques for the Beginning Organic Chemistry Laboratory.

    ERIC Educational Resources Information Center

    Leonard, Jack E.

    1981-01-01

    Describes a sequence of experiments developed at Texas A&M University for use in one-semester and two-semester (nonmajors) organic chemistry courses to teach a maximum number of separation and purification techniques such as distillations, recrystallization, liquid-liquid extraction, and chromatography. (SK)

  3. Synchronous Stroboscopic Electronic Speckle Pattern Interferometry

    NASA Astrophysics Data System (ADS)

    Soares, Oliverio D. D.

    1986-10-01

    Electronic Speckle Pattern Interferometry (E.S.P.I) oftenly called Electronic Holography is a practical powerful technique in non-destructive testing. Practical capabilities of the technique have been improved by fringe betterment and the control of analysis in the time domain, in particular, the scanning of the vibration cycle, with introduction of: synchronized amplitude and phase modulated pulse illumination, microcomputer control, fibre optics design, and moire evaluation techniques.

  4. Characterizing the temporal patterns of avian influenza virus introduction into Japan by migratory birds

    PubMed Central

    ONUMA, Manabu; KAKOGAWA, Masayoshi; YANAGISAWA, Masae; HAGA, Atsushi; OKANO, Tomomi; NEAGARI, Yasuko; OKANO, Tsukasa; GOKA, Koichi; ASAKAWA, Mitsuhiko

    2017-01-01

    The objectives of the present study were to observe the temporal pattern of avian influenza virus (AIV) introduction into Japan and to determine which migratory birds play an important role in introducing AIV. In total, 19,407 fecal samples from migratory birds were collected at 52 sites between October 2008 and May 2015. Total nucleic acids extracted from the fecal samples were subjected to reverse transcription loop–mediated isothermal amplification to detect viral RNA. Species identification of host migratory birds was conducted by DNA barcoding for positive fecal samples. The total number of positive samples was 352 (prevalence, 1.8%). The highest prevalence was observed in autumn migration, and a decrease in prevalence was observed. During autumn migration, central to southern Japan showed a prevalence higher than the overall prevalence. Thus, the main AIV entry routes may involve crossing the Sea of Japan and entry through the Korean Peninsula. Species identification was successful in 221 of the 352 positive samples. Two major species sequences were identified: the Mallard/Eastern Spot-billed duck group (115 samples; 52.0%) and the Northern pintail (61 samples; 27.6%). To gain a better understanding of the ecology of AIV in Japan and the introduction pattern of highly pathogenic avian influenza viruses, information regarding AIV prevalence by species, the prevalence of hatch-year migratory birds, migration patterns and viral subtypes in fecal samples using egg inoculation and molecular-based methods in combination is required. PMID:28484128

  5. Effect of technique and impression material on the vertical misfit of a screw-retained, three-unit implant bridge: An in vitro study

    PubMed Central

    Haghi, Hamidreza Rajati; Shiehzadeh, Masoud; Nakhaei, Mohammadreza; Ahrary, Fatemeh; Sabzevari, Saeid

    2017-01-01

    Introduction: A dental impression is a negative imprint of an oral structure that can be used to produce a positive cast of a patient's teeth as a permanent record. The accuracy of the impression affects the accuracy of the cast, and a precise impression is needed in order to create prosthesis with optimal fitting. Minimization of misfit is an important aim in prosthesis science and dental implants. The aim of this study was to evaluate the effects of the materials and techniques used to take an impression on the vertical misfit of implant-supported, screw-retained, three-unit bridges. Materials and Methods: The principal model used was an acrylic block with two ITI implants. A 1.5-mm abutment was attached to fixtures with torque of 25 N.cm. A base-metal framework was built on the abutment in the acrylic block. The abutments of the acrylic model were unscrewed and fixture-level impressions were made. The impression techniques included open/closed-tray techniques and the impression materials were polyether and polyvinyl siloxane. Forty acrylic custom trays were built for each impression. The marginal gap in the framework at three points (buccal, lingual, and distal) was measured using an optical microscope with ×250. Results: It is demonstrated that in all 360 evaluated samples, the mean vertical misfit in polyether samples of molar and premolar teeth was significantly lower than in polyvinyl siloxane (P < 0.001 and P = 0.017, respectively) in all three locations of the molar and lingual premolar examined (buccal, lingual, and distal), the mean vertical misfit of the polyether samples was significantly lower than those of polyvinyl siloxane (P < 0.01). On the other hand, although the mean vertical misfit using the open-tray technique in the molar teeth was significantly lower than with the closed-tray method (P = 0.002), no statistical difference was seen between the open-tray and closed-tray technique in general (P = 0.87). Conclusion: Within the limitations of this study, the following conclusions can be drawn: The impression method had no effect on marginal discrepancy of 3-unit screw retained fixed partial dentures. A higher marginal accuracy was obtained using polyether impression material compared to polyvinyl siloxane. PMID:28216844

  6. The Impact of Teaching the Subjects under "Science in Time" Unit in the Social Studies Class in the 7th Grade Using Jigsaw Technique on the Academic Success of the Students

    ERIC Educational Resources Information Center

    Er, Harun

    2017-01-01

    The main point in today's educational approach is that it is based on a student-centered approach. One of the alternative instruction techniques having a convenient content for this system is the jigsaw technique. Since the introduction of this technique, it has been applied into many different fields of education, and determined that it…

  7. Bayesian Processor of Output for Probabilistic Quantitative Precipitation Forecasting

    NASA Astrophysics Data System (ADS)

    Krzysztofowicz, R.; Maranzano, C. J.

    2006-05-01

    The Bayesian Processor of Output (BPO) is a new, theoretically-based technique for probabilistic forecasting of weather variates. It processes output from a numerical weather prediction (NWP) model and optimally fuses it with climatic data in order to quantify uncertainty about a predictand. The BPO is being tested by producing Probabilistic Quantitative Precipitation Forecasts (PQPFs) for a set of climatically diverse stations in the contiguous U.S. For each station, the PQPFs are produced for the same 6-h, 12-h, and 24-h periods up to 84- h ahead for which operational forecasts are produced by the AVN-MOS (Model Output Statistics technique applied to output fields from the Global Spectral Model run under the code name AVN). The inputs into the BPO are estimated as follows. The prior distribution is estimated from a (relatively long) climatic sample of the predictand; this sample is retrieved from the archives of the National Climatic Data Center. The family of the likelihood functions is estimated from a (relatively short) joint sample of the predictor vector and the predictand; this sample is retrieved from the same archive that the Meteorological Development Laboratory of the National Weather Service utilized to develop the AVN-MOS system. This talk gives a tutorial introduction to the principles and procedures behind the BPO, and highlights some results from the testing: a numerical example of the estimation of the BPO, and a comparative verification of the BPO forecasts and the MOS forecasts. It concludes with a list of demonstrated attributes of the BPO (vis- à-vis the MOS): more parsimonious definitions of predictors, more efficient extraction of predictive information, better representation of the distribution function of predictand, and equal or better performance (in terms of calibration and informativeness).

  8. An Introduction to Atomic Layer Deposition with Thermal Applications

    NASA Technical Reports Server (NTRS)

    Dwivedi, Vivek H.

    2015-01-01

    Atomic Layer Deposition (ALD) is a cost effective nano-manufacturing technique that allows for the conformal coating of substrates with atomic control in a benign temperature and pressure environment. Through the introduction of paired precursor gases thin films can be deposited on a myriad of substrates ranging from glass, polymers, aerogels, and metals to high aspect ratio geometries. This talk will focus on the utilization of ALD for engineering applications.

  9. Exploring critical uncertainties in pathway assessments of human-assisted introductions of alien forest species in Canada

    Treesearch

    Denys Yemshanov; Frank H. Koch; Mark J. Ducey; Marty Siltanen; Kirsty Wilson; Klaus Koehler

    2013-01-01

    Long-distance introductions of alien species are often driven by socioeconomic factors, such that conventional “biological” invasion models may not be capable of estimating spread fully and reliably. In this study, we demonstrate a new technique for assessing and reconstructing human-mediated pathways of alien forest species entries to major settlements in Canada via...

  10. Event-Related Potentials (ERPs) in Second Language Research: A Brief Introduction to the Technique, a Selected Review, and an Invitation to Reconsider Critical Periods in L2

    ERIC Educational Resources Information Center

    Steinhauer, Karsten

    2014-01-01

    This article provides a selective overview of recent event-related brain potential (ERP) studies in L2 morpho-syntax, demonstrating that the ERP evidence supporting the critical period hypothesis (CPH) may be less compelling than previously thought. The article starts with a general introduction to ERP methodology and language-related ERP profiles…

  11. Introduction of External, Independent Testing in "New Countries": Successes and Defeats of the Introduction of Modern Educational Assessment Techniques in Former Soviet and Socialist Countries

    ERIC Educational Resources Information Center

    Bakker, Steven

    2012-01-01

    A particular trait of the educational system under socialist reign was accountability at the input side--appropriate facilities, centrally decided curriculum, approved text-books, and uniformly trained teachers--but no control on the output. It was simply assumed that it met the agreed standards, which was, in turn, proven by the statistics…

  12. Quantum well intermixing of indium gallium arsenide(phosphorus)/indium phosphorus heterostructures

    NASA Astrophysics Data System (ADS)

    Haysom, Joan E.

    This thesis studies several aspects of the interdiffusion of InGaAs(P)/InP quantum well (QW) heterostructures, from the fundamental defect mechanisms, through optimization of processing parameters, to novel device applications. Conclusions from each of these areas have been drawn which further the scientific understanding and the manufacturability of the technique. The thermal stability of a series of different wafers is studied to highlight how poor quality of growth can cause increased interdiffusion, and to review the requirements for achieving repeatable annealing. Purposeful and controlled interdiffusion is accomplished through the introduction of excess defects into layers above the QWs, which during a subsequent anneal, diffuse through the QWs and enhance interdiffusion of atoms of the QWs with atoms of the barriers. These excess defects are introduced using two different techniques, via growth at low temperatures (LT) using chemical beam epitaxy (CBE), and via implantation of phosphorus ions. The CBE LT growth technique is new, and reported for the first time in this thesis. Characterization of the as-grown layers leads us to believe that they have an excess of phosphorus. The diffusion rate of the mobile defects which cause the intermixing is also measured, and the interdiffusion is shown to occur predominantly on the group-V sublattice. Due to many similarities between this and the results of the implantation technique, it is proposed that these mobile defects are the same for both intermixing approaches, and that the behaviour can be explained by a phosphorus interstitial mechanism. Annealing recipes for the implantation-induced technique are optimized, and the sample-to-sample reproducibility of the blueshift for this method was found to be quite good (standard deviations of ˜6 meV on blueshifts of ˜70 meV). The lateral selectivity and refractive index changes are characterized, and used in combination to create novel buried waveguide devices.

  13. Measuring sperm backflow following female orgasm: a new method

    PubMed Central

    King, Robert; Dempsey, Maria; Valentine, Katherine A.

    2016-01-01

    Background Human female orgasm is a vexed question in the field while there is credible evidence of cryptic female choice that has many hallmarks of orgasm in other species. Our initial goal was to produce a proof of concept for allowing females to study an aspect of infertility in a home setting, specifically by aligning the study of human infertility and increased fertility with the study of other mammalian fertility. In the latter case - the realm of oxytocin-mediated sperm retention mechanisms seems to be at work in terms of ultimate function (differential sperm retention) while the proximate function (rapid transport or cervical tenting) remains unresolved. Method A repeated measures design using an easily taught technique in a natural setting was used. Participants were a small (n=6), non-representative sample of females. The introduction of a sperm-simulant combined with an orgasm-producing technique using a vibrator/home massager and other easily supplied materials. Results The sperm flowback (simulated) was measured using a technique that can be used in a home setting. There was a significant difference in simulant retention between the orgasm (M=4.08, SD=0.17) and non-orgasm (M=3.30, SD=0.22) conditions; t (5)=7.02, p=0.001. Cohen's d=3.97, effect size r=0.89. This indicates a medium to small effect size. Conclusions This method could allow females to test an aspect of sexual response that has been linked to lowered fertility in a home setting with minimal training. It needs to be replicated with a larger sample size. PMID:27799082

  14. Measuring sperm backflow following female orgasm: a new method.

    PubMed

    King, Robert; Dempsey, Maria; Valentine, Katherine A

    2016-01-01

    Human female orgasm is a vexed question in the field while there is credible evidence of cryptic female choice that has many hallmarks of orgasm in other species. Our initial goal was to produce a proof of concept for allowing females to study an aspect of infertility in a home setting, specifically by aligning the study of human infertility and increased fertility with the study of other mammalian fertility. In the latter case - the realm of oxytocin-mediated sperm retention mechanisms seems to be at work in terms of ultimate function (differential sperm retention) while the proximate function (rapid transport or cervical tenting) remains unresolved. A repeated measures design using an easily taught technique in a natural setting was used. Participants were a small (n=6), non-representative sample of females. The introduction of a sperm-simulant combined with an orgasm-producing technique using a vibrator/home massager and other easily supplied materials. The sperm flowback (simulated) was measured using a technique that can be used in a home setting. There was a significant difference in simulant retention between the orgasm (M=4.08, SD=0.17) and non-orgasm (M=3.30, SD=0.22) conditions; t (5)=7.02, p=0.001. Cohen's d=3.97, effect size r=0.89. This indicates a medium to small effect size. This method could allow females to test an aspect of sexual response that has been linked to lowered fertility in a home setting with minimal training. It needs to be replicated with a larger sample size.

  15. Fiber-Optic Chemical Sensors and Fiber-Optic Bio-Sensors.

    PubMed

    Pospíšilová, Marie; Kuncová, Gabriela; Trögl, Josef

    2015-09-30

    This review summarizes principles and current stage of development of fiber-optic chemical sensors (FOCS) and biosensors (FOBS). Fiber optic sensor (FOS) systems use the ability of optical fibers (OF) to guide the light in the spectral range from ultraviolet (UV) (180 nm) up to middle infrared (IR) (10 μm) and modulation of guided light by the parameters of the surrounding environment of the OF core. The introduction of OF in the sensor systems has brought advantages such as measurement in flammable and explosive environments, immunity to electrical noises, miniaturization, geometrical flexibility, measurement of small sample volumes, remote sensing in inaccessible sites or harsh environments and multi-sensing. The review comprises briefly the theory of OF elaborated for sensors, techniques of fabrications and analytical results reached with fiber-optic chemical and biological sensors.

  16. User's manual for three dimensional FDTD version B code for scattering from frequency-dependent dielectric materials

    NASA Technical Reports Server (NTRS)

    Beggs, John H.; Luebbers, Raymond J.; Kunz, Karl S.

    1992-01-01

    The Penn State Finite Difference Time Domain Electromagnetic Code Version B is a three dimensional numerical electromagnetic scattering code based upon the Finite Difference Time Domain Technique (FDTD). The supplied version of the code is one version of our current three dimensional FDTD code set. This manual provides a description of the code and corresponding results for several scattering problems. The manual is organized into 14 sections: introduction, description of the FDTD method, operation, resource requirements, Version B code capabilities, a brief description of the default scattering geometry, a brief description of each subroutine, a description of the include file, a discussion of radar cross section computations, a discussion of some scattering results, a sample problem setup section, a new problem checklist, references and figure titles.

  17. Nonperturbative light-front Hamiltonian methods

    NASA Astrophysics Data System (ADS)

    Hiller, J. R.

    2016-09-01

    We examine the current state-of-the-art in nonperturbative calculations done with Hamiltonians constructed in light-front quantization of various field theories. The language of light-front quantization is introduced, and important (numerical) techniques, such as Pauli-Villars regularization, discrete light-cone quantization, basis light-front quantization, the light-front coupled-cluster method, the renormalization group procedure for effective particles, sector-dependent renormalization, and the Lanczos diagonalization method, are surveyed. Specific applications are discussed for quenched scalar Yukawa theory, ϕ4 theory, ordinary Yukawa theory, supersymmetric Yang-Mills theory, quantum electrodynamics, and quantum chromodynamics. The content should serve as an introduction to these methods for anyone interested in doing such calculations and as a rallying point for those who wish to solve quantum chromodynamics in terms of wave functions rather than random samplings of Euclidean field configurations.

  18. In vivo brain microdialysis: advances in neuropsychopharmacology and drug discovery.

    PubMed

    Darvesh, Altaf S; Carroll, Richard T; Geldenhuys, Werner J; Gudelsky, Gary A; Klein, Jochen; Meshul, Charles K; Van der Schyf, Cornelis J

    2011-02-01

    INTRODUCTION: Microdialysis is an important in vivo sampling technique, useful in the assay of extracellular tissue fluid. The technique has both pre-clinical and clinical applications but is most widely used in neuroscience. The in vivo microdialysis technique allows measurement of neurotransmitters such as acetycholine (ACh), the biogenic amines including dopamine (DA), norepinephrine (NE) and serotonin (5-HT), amino acids such as glutamate (Glu) and gamma aminobutyric acid (GABA), as well as the metabolites of the aforementioned neurotransmitters, and neuropeptides in neuronal extracellular fluid in discrete brain regions of laboratory animals such as rodents and non-human primates. AREAS COVERED: In this review we present a brief overview of the principles and procedures related to in vivo microdialysis and detail the use of this technique in the pre-clinical measurement of drugs designed to be used in the treatment of chemical addiction, neurodegenerative diseases such as Alzheimer's disease (AD), Parkinson's disease (PD) and as well as psychiatric disorders such as attention-deficit/hyperactivity disorder (ADHD) and schizophrenia. This review offers insight into the tremendous utility and versatility of this technique in pursuing neuropharmacological investigations as well its significant potential in rational drug discovery. EXPERT OPINION: In vivo microdialysis is an extremely versatile technique, routinely used in the neuropharmacological investigation of drugs used for the treatment of neurological disorders. This technique has been a boon in the elucidation of the neurochemical profile and mechanism of action of several classes of drugs especially their effects on neurotransmitter systems. The exploitation and development of this technique for drug discovery in the near future will enable investigational new drug candidates to be rapidly moved into the clinical trial stages and to market thus providing new successful therapies for neurological diseases that are currently in demand.

  19. High resolution spectroscopy from ground and space: Introduction

    NASA Astrophysics Data System (ADS)

    Ward, William E.

    In contrast to the broad brush approach often used for the sounding of atmospheric constituents, high resolution spectroscopy is a refined, efficient and often elegant tool which uses small spectral regions to probe specific phenomena. Application areas range from wind and temperature measurements in terrestrial and planetary atmospheres, to magnetic field measurements on the sun. In most cases, subtle changes in line shape or line position are used with a priori information to generate the geophysical information of interest. Use of this technique for space applications started in the 1960's and was a natural extension of the spectroscopic heritage which was started by Fabry and Perot and Michelson over 100 year ago. This field has evolved over the past 50 years in response to refinements in detector technologies, manufacturing techniques and the development of active techniques using lasers. This session will trace the evolution of these techniques over the past half-century and showcase the state-of-the-art today. Within Canada, Gordon Shepherd has played a hand in many of the developments in this technique. This introduction will briefly summarize this field and provide a short historical sketch of Shepherd's contributions as a lead into his keynote review of this topic.

  20. Petrographic manual : petrographic methods of examining hardened concrete, including introduction, sample preparation, questions and suggestions, and reading list.

    DOT National Transportation Integrated Search

    1991-01-01

    This manual was undertaken to record for all persons wishing to do concrete petrography the petrographic procedures that have been found useful here at the Virginia Transportation Research Council. This interim report is made up of the introduction, ...

  1. Ensemble-Biased Metadynamics: A Molecular Simulation Method to Sample Experimental Distributions

    PubMed Central

    Marinelli, Fabrizio; Faraldo-Gómez, José D.

    2015-01-01

    We introduce an enhanced-sampling method for molecular dynamics (MD) simulations referred to as ensemble-biased metadynamics (EBMetaD). The method biases a conventional MD simulation to sample a molecular ensemble that is consistent with one or more probability distributions known a priori, e.g., experimental intramolecular distance distributions obtained by double electron-electron resonance or other spectroscopic techniques. To this end, EBMetaD adds an adaptive biasing potential throughout the simulation that discourages sampling of configurations inconsistent with the target probability distributions. The bias introduced is the minimum necessary to fulfill the target distributions, i.e., EBMetaD satisfies the maximum-entropy principle. Unlike other methods, EBMetaD does not require multiple simulation replicas or the introduction of Lagrange multipliers, and is therefore computationally efficient and straightforward in practice. We demonstrate the performance and accuracy of the method for a model system as well as for spin-labeled T4 lysozyme in explicit water, and show how EBMetaD reproduces three double electron-electron resonance distance distributions concurrently within a few tens of nanoseconds of simulation time. EBMetaD is integrated in the open-source PLUMED plug-in (www.plumed-code.org), and can be therefore readily used with multiple MD engines. PMID:26083917

  2. Novel Techniques for Quantification of Correlation Between Primary Liquid Jet Breakup and Downstream Spray Characteristics

    DTIC Science & Technology

    2016-05-08

    unlimited. 5 1. Introduction Several liquid -fuelled combustion systems, such as liquid propellant rocket engines and gas turbines...AFRL-AFOSR-JP-TR-2016-0084 Novel techniques for quantification of correlation between primary liquid jet breakup and downstream spray characteristics...to 17 Apr 2016 4.  TITLE AND SUBTITLE Novel techniques for quantification of correlation between primary liquid jet breakup and downstream spray

  3. Novel Techniques for Quantification of Correlation Between Primary Liquid Jet Breakup and Downstream Spray Characteristics

    DTIC Science & Technology

    2016-10-05

    unlimited. 5 1. Introduction Several liquid -fuelled combustion systems, such as liquid propellant rocket engines and gas turbines...AFRL-AFOSR-JP-TR-2016-0084 Novel techniques for quantification of correlation between primary liquid jet breakup and downstream spray characteristics...to 17 Apr 2016 4.  TITLE AND SUBTITLE Novel techniques for quantification of correlation between primary liquid jet breakup and downstream spray

  4. The phonetics of talk in interaction--introduction to the special issue.

    PubMed

    Ogden, Richard

    2012-03-01

    This overview paper provides an introduction to work on naturally-occurring speech data, combining techniques of conversation analysis with techniques and methods from phonetics. The paper describes the development of the field, highlighting current challenges and progress in interdisciplinary work. It considers the role of quantification and its relationship to a qualitative methodology. It presents the conversation analytic notion of sequence as a version of context, and argues that sequences of talk constrain relevant phonetic design, and so provide one account for variability in naturally occurring speech. The paper also describes the manipulation of speech and language on many levels simultaneously. All of these themes occur and are explored in more detail in the papers contained in this special issue.

  5. Genetic analysis of invasive Asian Black Carp (Mylopharyngodon piceus) in the Mississippi River Basin: evidence for multiple introductions

    USGS Publications Warehouse

    Hunter, Margaret E.; Nico, Leo G.

    2015-01-01

    Invasive Asian Black Carp (Mylopharyngodon piceus) have been present in USA aquaculture facilities since the 1980s and wild Black Carp have been found in the Mississippi River Basin since the early 1990s. This study characterizes the genetic diversity and relatedness of the Basin’s Black Carp and clarifies the introduction history. Analyses focused on three mitochondrial markers (control region, cytochrome-b, and 16S) and seven nuclear microsatellite markers (nDNA), using aquaculture and wild-caught samples collected in the upper and lower Mississippi Basin. Of the three mitochondrial haplotypes, two were shared between the aquaculture and wild populations, while a third was only present in upper Mississippi wild-caught specimens. Due to the presence of diploid and triploid fish, microsatellite markers were scored as pseudodominant and revealed low polymorphism (NA = 4.6, NA Ave = 1.5). Nuclear Bayesian clustering analyses identified two genetically distinct groups and four subclusters, each primarily composed of a unique haplotype. Samples from three aquaculture farms were assigned to group 1, while a fourth farm included samples from both groups 1 and 2. Wild-caught fish from the upper Basin were predominantly group 1, whereas wild samples from the lower Mississippi were assigned to both genetic groups. The presence of divergent haplotypes and distinct nDNA groups, along with geographic distribution patterns, indicate that wild populations in the basin likely resulted from multiple introductions. Genetic similarities between wild and captive populations support claims that aquaculture is the introduction source, but a shortage of samples and a history of repeated transfers among facilities obscure the precise pathway.

  6. A study of the dynamics of Salmonella infection in turkey breeding, rearing and finishing houses with special reference to elimination, persistence and introduction of Salmonella.

    PubMed

    Mueller-Doblies, Doris; Carrique-Mas, Juan J; Davies, Robert H

    2014-01-01

    In this descriptive study, the dynamics of Salmonella infection of turkey flocks were investigated by repeated sampling of houses where Salmonella had been identified. The aim of the study was to identify the most common scenarios involved in elimination, persistence and introduction of Salmonella in the different branches of the turkey industry. Sixty-two houses on 34 turkey farms (comprising breeding, rearing and finishing farms) were sampled longitudinally, starting with the identification of a positive flock. A total of 117 follow-on flocks were tested and cleaning and disinfection (C&D) was assessed during 66 post-C&D visits. A total of 155 incidents (clearance, persistence or introduction of Salmonella) were recorded. Persistence was seen in 35.5% of incidents and was seen more frequently in breeding and rearing houses compared with finishing houses. Most persistence incidents were the result of insufficient C&D. Clearance was seen in 40% of incidents and was more often observed in finishing houses than in breeding or rearing houses. Introduction was seen in 24.5% of incidents and was more common in breeding and finishing flocks than in rearing flocks. Contamination of a house with Salmonella Typhimurium was more likely to be cleared compared with other serovars. The total number of positive samples found at a post-C&D visit was correlated with the probability of carry-over of infection, whereas the location of the positive samples seemed to be less important. Our highly sensitive post-C&D sampling method allowed us to predict a negative follow-on flock in most cases.

  7. Inquiry-Based Experiments for Large-Scale Introduction to PCR and Restriction Enzyme Digests

    ERIC Educational Resources Information Center

    Johanson, Kelly E.; Watt, Terry J.

    2015-01-01

    Polymerase chain reaction and restriction endonuclease digest are important techniques that should be included in all Biochemistry and Molecular Biology laboratory curriculums. These techniques are frequently taught at an advanced level, requiring many hours of student and faculty time. Here we present two inquiry-based experiments that are…

  8. Methods of Selecting Industries for Depressed Areas--An Introduction to Feasibility Studies. Developing Job Opportunities 2.

    ERIC Educational Resources Information Center

    Klaassen, Leo H.

    This report presents severl alternative methods which may be employed by local authorities in identifying likely prospects for local industrialization, and describes a specialized input-output technique to define inter-industry relations and inter-regional relations of industries. This technique is applied, for illustrative purposes, to three…

  9. Integration of Video-Based Demonstrations to Prepare Students for the Organic Chemistry Laboratory

    ERIC Educational Resources Information Center

    Nadelson, Louis S.; Scaggs, Jonathan; Sheffield, Colin; McDougal, Owen M.

    2015-01-01

    Consistent, high-quality introductions to organic chemistry laboratory techniques effectively and efficiently support student learning in the organic chemistry laboratory. In this work, we developed and deployed a series of instructional videos to communicate core laboratory techniques and concepts. Using a quasi-experimental design, we tested the…

  10. Re-Operationalizing Established Groups in Brainstorming: Validating Osborn's Claims

    ERIC Educational Resources Information Center

    Levine, Kenneth J.; Heuett, Kyle B.; Reno, Katie M.

    2017-01-01

    Since the introduction of brainstorming as an idea-generation technique to address organizational problems, researchers have struggled to replicate some of the claims around the technique. One major concern has been the differences in the number of ideas generated between established groups as found in industry versus the non-established groups…

  11. Figure Analysis: An Implementation Dialogue

    ERIC Educational Resources Information Center

    Wiles, Amy M.

    2016-01-01

    Figure analysis is a novel active learning teaching technique that reinforces visual literacy. Small groups of students discuss diagrams in class in order to learn content. The instructor then gives a brief introduction and later summarizes the content of the figure. This teaching technique can be used in place of lecture as a mechanism to deliver…

  12. The Throws: Contemporary Theory, Technique and Training.

    ERIC Educational Resources Information Center

    Wilt, Fred, Ed.

    This compilation of articles covers the subject of four throwing events--shot put, discus throw, hammer throw, and javelin throw. The history of the art and science of throwing is traced from ancient to modern times in the introduction. Theories on training and techniques of throwing are presented in essays contributed by coaches from the United…

  13. Variables Associated with Environmental Scanning among Clinicians at Substance Abuse Treatment Clinics

    ERIC Educational Resources Information Center

    Koch, Alison L.; Arfken, Cynthia L.; Agius, Elizabeth; Dickson, Marcus W.; Mitchelson, Jacqueline K.

    2005-01-01

    Introduction: Environmental scanning, as a component of absorptive capacity, has been shown to be associated with increased use of innovative treatment techniques at substance abuse treatment programmes. As the transfer of innovative, evidence-based treatment techniques from research to practice is gaining attention, we aimed to identify variables…

  14. Basic River Canoeing: Complete Instructional Guide to Whitewater Canoeing. The New Edition.

    ERIC Educational Resources Information Center

    McNair, Robert E.; And Others

    From its beginnings, river canoeing in the United States has grown enormously. New equipment, materials, and techniques have advanced the capabilities of boaters. This handbook explains the techniques of whitewater canoeing, with concise instructions and clear illustrations, for a safe introduction to the sport. Oriented to the open two-person…

  15. Proceedings: Basic Assessment and Intervention Techniques for Deaf-Blind and Multihandicapped Children.

    ERIC Educational Resources Information Center

    Rouin, Carole

    Presented are proceedings of a conference which focused on basic assessment and intervention techniques for use in the education and habilitation of lower functioning deaf blind and multihandicapped children. Following an introduction by D. Overbeck are papers with the following titles and authors: "Considerations in the Psychological Assessment…

  16. Determination of mercury compounds in fish by microwave-assisted extraction and liquid chromatography-vapor generation-inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Chiou, Chwei-Sheng; Jiang, Shiuh-Jen; Kumar Danadurai, K. Suresh

    2001-07-01

    A method employing a vapor generation system and LC combined with inductively coupled plasma mass spectrometry (LC-ICP-MS) is presented for the determination of mercury in biological tissues. An open vessel microwave digestion system was used to extract the mercury compounds from the sample matrix. The efficiency of the mobile phase, a mixture of L-cysteine and 2-mercaptoethanol, was evaluated for LC separation of inorganic mercury [Hg(II)], methylmercury (methyl-Hg) and ethylmercury (ethyl-Hg). The sensitivity, detection limits and repeatability of the liquid chromatography (LC) ICP-MS system with a vapor generator were comparable to, or better than, that of an LC-ICP-MS system with conventional pneumatic nebulization, or other sample introduction techniques. The experimental detection limits for various mercury species were in the range of 0.05-0.09 ng ml -1 Hg, based on peak height. The proposed method was successfully applied to the determination of mercury compounds in a swordfish sample purchased from the local market. The accuracy of the method was evaluated by analyzing a marine biological certified reference material (DORM-2, NRCC).

  17. Production and Characterization of a Ag- and Zn-Doped Glass-Ceramic Material and In Vitro Evaluation of Its Biological Effects

    NASA Astrophysics Data System (ADS)

    Baghbani, Fatemeh; Moztarzadeh, Fathollah; Mozafari, Masoud; Raz, Majid; Rezvani, Hamideh

    2016-08-01

    Bioactive glasses in the system SiO2-CaO-Na2O-P2O5-MgO with different amounts of zinc (Zn) and silver (Ag) were synthesized by the sol-gel technique and characterized. The bioactivity was studied during in vitro assays: the ability of hydroxycarbonate apatite (HCA) layer to form on the glass surface was examined after contact with simulated body fluid (SBF). The x-ray diffraction, Fourier transform infrared spectroscopy, scanning electron microscopy, and inductively coupled plasma atomic emission spectrometry (ICP) studies were performed after immersion in vitro assays. Also, the antibacterial and antifungal activities of glass samples against Pseudomonas aeruginosa (ATCC 27853), E. coli (ATCC 25922), and Candida albicans were measured by the halo zone test. Introduction of zinc and silver as the trace elements induces several modifications on the observed phenomena at the glass surface and in SBF solution after immersion of the samples. The chemical durability of the glasses, the formation of the silica-rich layer, and the crystallization of the HCA layer were affected. Samples with the higher content of zinc and silver exhibited an excellent antibacterial/antifungal activity.

  18. Learning from the private sector: towards a keener understanding of the end-user for microbicide introduction planning

    PubMed Central

    Lin, Amy H; Breger, Tiffany L; Barnhart, Matthew; Kim, Ann; Vangsgaard, Charlotte; Harris, Emily

    2014-01-01

    Introduction In planning for the introduction of vaginal microbicides and other new antiretroviral (ARV)-based prevention products for women, an in-depth understanding of potential end-users will be critically important to inform strategies to optimize uptake and long-term adherence. User-centred private sector companies have contributed to the successful launch of many different types of products, employing methods drawn from behavioural and social sciences to shape product designs, marketing messages and communication channels. Examples of how the private sector has adapted and applied these techniques to make decisions around product messaging and targeting may be instructive for adaptation to microbicide introduction. Discussion In preparing to introduce a product, user-centred private sector companies employ diverse methods to understand the target population and their lifestyles, values and motivations. ReD Associates’ observational research on user behaviours in the packaged food and diabetes fields illustrates how ‘tag along’ or ‘shadowing’ techniques can identify sources of non-adherence. Another open-ended method is self-documentation, and IDEO's mammography research utilized this to uncover user motivations that extended beyond health. Mapping the user journey is a quantitative approach for outlining critical decision-making stages, and Monitor Inclusive Markets applied this framework to identify toilet design opportunities for the rural poor. Through an iterative process, these various techniques can generate hypotheses on user drop-off points, quantify where drop-off is highest and prioritize areas of further research to uncover usage barriers. Although research constraints exist, these types of user-centred techniques have helped create effective messaging, product positioning and packaging of health products as well as family planning information. These methods can be applied to microbicide acceptability testing outside of clinical trials to design microbicide marketing that enhances product usage. Conclusions The introduction of microbicide products presents an ideal opportunity to draw on the insights from user-centred private sector companies’ approaches, which can complement other methods that have been more commonly utilized in microbicide research to date. As microbicides move from clinical trials to real-world implementation, there will be more opportunities to combine a variety of approaches to understand end-users, which can lead to a more effective product launch and ultimately greater impact on preventing HIV infections. PMID:25224619

  19. Marine origin of pyritic sulfur in the Lower Bakerstown coal bed, Castleman coal field, Maryland (U.S.A.)

    USGS Publications Warehouse

    Lyons, P.C.; Whelan, J.F.; Dulong, F.T.

    1989-01-01

    The amount, kind, distribution, and genesis of pyrite in the Lower Bakerstown coal bed in a 150 ?? 15 m area of the Bettinger mine, Castleman coal field, Maryland, were studied by various analytical techniques. The mined coal, which had a nonmarine roof rock, contained 1.4-2.8 wt.% total sulfur, generally much lower than the high-sulfur coal (> 3.0 wt.% total S) to the north, which is associated with marine roof rocks. Small-scale systematic and nonsystematic variations in total sulfur and pyrite distribution were found in the mined area. In the column sample, most of the pyrite was found in the upper 9 cm of the 69-cm-thick mined coal and occurred mainly as a pyrite lens containing cell fillings in seed-fern tissue (coal ball). As-bearing pyrite was detected by laser microprobe techniques in the cell walls of this tissue but not elsewhere in the column sample. This may indicate that the As was derived from decomposition of organic matter in the cell walls. The sulfur isotopic composition and distribution of pyrite in the coal are consistent with introduction of marine sulfate shortly after peat deposition, followed by bacterial reduction and pyrite precipitation. Epigenetic cleat pyrite in the coal is isotopically heavy, implying that later aqueous sulfate was 34S-enriched. ?? 1989.

  20. Effect of varying Ga content in ZnO:GaN solid solution synthesized by solution combustion technique for photocatalytic applications

    NASA Astrophysics Data System (ADS)

    Menon, Sumithra Sivadas; Janani, R.; Baskar, K.; Gupta, Bhavana; Singh, Shubra

    2017-05-01

    ZnO:GaN (oxy)nitride solid solution has been established as the most efficient non-oxide photocatalyst for water splitting under visible irradiation with one step photoexcitation and also boasts a band gap tunability from 2.8 eV to 2.5 eV[1]. The solid solution of GaN in ZnO is formed by the intersubstitution of few of Zn/O ions by Ga/N ions, and this results in the introduction of new defect levels above the valence band which narrows the effective band gap enabling activity under visible region of spectra. In this work, we report the synthesis of ZnO:GaN solid solution by a solution combustion technique where metal nitrates and urea are used as precursors. The Zn/Ga ratio was varied from 16 to 1 in the precursors. The as synthesized samples were characterized as phase pure by X-ray diffraction, where the wurtzite structure was retained up to Zn/Ga ratio of 5. The Diffuse reflectance spectroscopy studies revealed that as the Ga content in the solid solution increases there is a reduction in band gap, from 2.9 eV to 2.4 eV. The reduced band gap of the samples facilitates its photocatalytic activity under visible region of the spectra as evaluated by photoelectrochemical measurements.

  1. Radio-frequency response of single pores and artificial ion channels

    NASA Astrophysics Data System (ADS)

    Kim, H. S.; Ramachandran, S.; Stava, E.; van der Weide, D. W.; Blick, R. H.

    2011-09-01

    Intercellular communication relies on ion channels and pores in cell membranes. These protein-formed channels enable the exchange of ions and small molecules to electrically and/or chemically interact with the cells. Traditionally, recordings on single-ion channels and pores are performed in the dc regime, due to the extremely high impedance of these molecular junctions. This paper is intended as an introduction to radio-frequency (RF) recordings of single-molecule junctions in bilipid membranes. First, we demonstrate how early approaches to using microwave circuitry as readout devices for ion channel formation were realized. The second step will then focus on how to engineer microwave coupling into the high-impedance channel by making use of bio-compatible micro-coaxial lines. We then demonstrate integration of an ultra-broadband microwave circuit for the direct sampling of single α-hemolysin pores in a suspended bilipid membrane. Simultaneous direct current recordings reveal that we can monitor and correlate the RF transmission signal. This enables us to relate the open-close states of the direct current to the RF signal. Altogether, our experiments lay the ground for an RF-readout technique to perform real-time in vitro recordings of pores. The technique thus holds great promise for research and drug screening applications. The possible enhancement of sampling rates of single channels and pores by the large recording bandwidth will allow us to track the passage of single ions.

  2. Procrastinating Behavior in Computer-Based Learning Environments to Predict Performance: A Case Study in Moodle

    PubMed Central

    Cerezo, Rebeca; Esteban, María; Sánchez-Santillán, Miguel; Núñez, José C.

    2017-01-01

    Introduction: Research about student performance has traditionally considered academic procrastination as a behavior that has negative effects on academic achievement. Although there is much evidence for this in class-based environments, there is a lack of research on Computer-Based Learning Environments (CBLEs). Therefore, the purpose of this study is to evaluate student behavior in a blended learning program and specifically procrastination behavior in relation to performance through Data Mining techniques. Materials and Methods: A sample of 140 undergraduate students participated in a blended learning experience implemented in a Moodle (Modular Object Oriented Developmental Learning Environment) Management System. Relevant interaction variables were selected for the study, taking into account student achievement and analyzing data by means of association rules, a mining technique. The association rules were arrived at and filtered through two selection criteria: 1, rules must have an accuracy over 0.8 and 2, they must be present in both sub-samples. Results: The findings of our study highlight the influence of time management in online learning environments, particularly on academic achievement, as there is an association between procrastination variables and student performance. Conclusion: Negative impact of procrastination in learning outcomes has been observed again but in virtual learning environments where practical implications, prevention of, and intervention in, are different from class-based learning. These aspects are discussed to help resolve student difficulties at various ages. PMID:28883801

  3. Procrastinating Behavior in Computer-Based Learning Environments to Predict Performance: A Case Study in Moodle.

    PubMed

    Cerezo, Rebeca; Esteban, María; Sánchez-Santillán, Miguel; Núñez, José C

    2017-01-01

    Introduction: Research about student performance has traditionally considered academic procrastination as a behavior that has negative effects on academic achievement. Although there is much evidence for this in class-based environments, there is a lack of research on Computer-Based Learning Environments (CBLEs) . Therefore, the purpose of this study is to evaluate student behavior in a blended learning program and specifically procrastination behavior in relation to performance through Data Mining techniques. Materials and Methods: A sample of 140 undergraduate students participated in a blended learning experience implemented in a Moodle (Modular Object Oriented Developmental Learning Environment) Management System. Relevant interaction variables were selected for the study, taking into account student achievement and analyzing data by means of association rules, a mining technique. The association rules were arrived at and filtered through two selection criteria: 1, rules must have an accuracy over 0.8 and 2, they must be present in both sub-samples. Results: The findings of our study highlight the influence of time management in online learning environments, particularly on academic achievement, as there is an association between procrastination variables and student performance. Conclusion: Negative impact of procrastination in learning outcomes has been observed again but in virtual learning environments where practical implications, prevention of, and intervention in, are different from class-based learning. These aspects are discussed to help resolve student difficulties at various ages.

  4. Development of molecular techniques for detection of lymphocystis disease virus in different marine fish species.

    PubMed

    Cano, I; Ferro, P; Alonso, M C; Bergmann, S M; Römer-Oberdörfer, A; Garcia-Rosado, E; Castro, D; Borrego, J J

    2007-01-01

    The development and evaluation of a protocol based on polymerase chain reaction (PCR) and nucleic acid hybridization techniques for the specific detection of lymphocystis disease virus (LCDV) in several marine fish species. The pair of primers for PCR, OBL3 and OBL4, was designed based on published nucleotide sequence (LCDV-1) and amplifies a fragment within the major capsid protein. The sensitivity was evaluated using DNA from purified viral particles, as well as from cells inoculated with several viral concentrations. The PCR combined with slot blot was the most sensitive methodology, detecting 2.5 ng of viral DNA. Using this methodology LCDV was detected at 5 days postinoculation from SAF-1 cells initially inoculated with 10(-5) TCID(50) ml(-1). The combination of PCR with membrane hybridization has also been proved to be adequate to detect LCDV from apparently healthy carriers by means of caudal fin sample analysis. This asymptomatic infection was also demonstrated by classical virological methods (cell culture and immunoblot). The protocol described in this study allows the specific detection of LCDV, both in cell cultures and in fin homogenates from asymptomatic fish. The detection of asymptomatic carriers by a rapid molecular method using caudal fin sampling, which does not imply animal killing, could be an important tool to control epizootics caused by LCDV, as fish could be analysed before their introduction and/or mobilization in farm facilities.

  5. Multiservice Procedures for the Tactical Employment of Nonlethal Weapons (NLW)

    DTIC Science & Technology

    1998-10-01

    capsicum (OC) spray, impact weapons, and internationally recognized open-hand control techniques. The US Army will award an additional skill identifier...dealing with people are truly the first line of nonlethal options. d. Oleoresin Capsicum Aerosol Train- ing. The subcourse is an introduction to the uses...Oleoresin Capsicum Aerosol Training 8.0 Open Hand Control 24.0 Impact Weapons 36.0 Introduction to Military Working Dogs 1.0 ROE/Law of War

  6. Identification of N-nitrosamines in treated drinking water using nanoelectrospray ionization high-field asymmetric waveform ion mobility spectrometry with quadrupole time-of-flight mass spectrometry.

    PubMed

    Zhao, Yuan Yuan; Liu, Xin; Boyd, Jessica M; Qin, Feng; Li, Jianjun; Li, Xing-Fang

    2009-01-01

    We report a nanoelectrospray ionization (nESI) with high-field asymmetric waveform ion mobility spectrometry (FAIMS) and tandem mass spectrometry (MS-MS) method for determination of small molecules of m/z 50 to 200 and its potential application in environmental analysis. Integration of nESI with FAIMS and MS-MS combines the advantages of these three techniques into one method. The nESI provides efficient sample introduction and ionization and allows for collection of multiple data from only microliters of samples. The FAIMS provides rapid separation, reduces or eliminates background interference, and improves the signal-to-noise ratio as much as 10-fold over nESI-MS-MS. The tandem quadrupole time-of-flight MS detection provides accurate mass and mass spectral measurements for structural identification. Characteristics of FAIMS compensation voltage (CV) spectra of seven nitrosamines, N-nitrosodimethylamine (NDMA), N-nitrosomethylethylamine (NMEA), N-nitrosodiethylamine (NDEA), N-nitrosodi-n-propylamine (NDPA), N-nitrosodi-n-butylamine (NDBA), N-nitrosopiperidine (NPip), and N-nitrosopyrrolidine (NPyr), were analyzed. The optimal CV of the nitrosamines (at DV -4000 V) were: -1.6 V, NDBA; 2.6 V, NDPA; 6.6 V, NPip; 8.8 V, NDEA; 13.2 V, NPyr; 14.4 V, NMEA; and 19.4 V, NDMA. Fragmentation patterns of the seven nitrosamines in the nESI-FAIMS-MS-MS were also obtained. The specific CV and MS-MS spectra resulted in positive identification of NPyr and NPip in a treated water sample, demonstrating the potential application of this technique in environmental analysis.

  7. A Study to Find Out the Full Immunization Coverage of 12 to 23-month old Children and Areas of Under-Performance using LQAS Technique in a Rural Area of Tripura

    PubMed Central

    Baidya, Subrata; Datta, Srabani; Mog, Chanda; Das, Shampa

    2017-01-01

    Introduction It is very important to analyze the factors which acts as obstacle in achieving 100% immunization among children. Lot Quality Assurance Sampling (LQAS) is one of the effective method to assess such barriers. Aim To assess the full immunization coverage among 12 to 23-month old children of rural field practice area under Department of Community Medicine, Agartala Government Medical College and identify the factors for failure of full immunization. Materials and Methods A community based cross-sectional study was conducted from November 2013 to October 2014 on children aged 12 to 23 months old of area under Mohanpur Community health centre. Using LQAS technique 330 samples were selected with multi-stage sampling, each sub-centre being one lot and two calculated to be the decision value. Data was collected using pre-designed pre-tested questionnaire during home visit and verifying immunization card and analysed by computer software SPSS version 21.0. Results The full immunization coverage among 12 to 23 months old children of Mohanpur area was found as 91.67%. Out of all the 22 sub-centres, 36.36% was found under performing as per pre-fixed criteria and the main reasons for failure of full immunization in those areas are unawareness of need of subsequent doses of vaccines and illness of the children. Conclusion LQAS is an effective method to identify areas of under-performance even though overall full immunization coverage is high. PMID:28384892

  8. MALDI-MS/MS with Traveling Wave Ion Mobility for the Structural Analysis of N-Linked Glycans

    NASA Astrophysics Data System (ADS)

    Harvey, David J.; Scarff, Charlotte A.; Crispin, Max; Scanlan, Christopher N.; Bonomelli, Camille; Scrivens, James H.

    2012-11-01

    The preference for singly charged ion formation by MALDI makes it a better choice than electrospray ionization for profiling mixtures of N-glycans. For structural analysis, fragmentation of negative ions often yields more informative spectra than fragmentation of positive ones but such ions are more difficult to produce from neutral glycans under MALDI conditions. This work investigates conditions for the formation of both positive and negative ions by MALDI from N-linked glycans released from glycoproteins and their subsequent MS/MS and ion mobility behaviour. 2,4,6-Trihydroxyacetophenone (THAP) doped with ammonium nitrate was found to give optimal ion yields in negative ion mode. Ammonium chloride or phosphate also yielded prominent adducts but anionic carbohydrates such as sulfated N-glycans tended to ionize preferentially. Carbohydrates adducted with all three adducts (phosphate, chloride, and nitrate) produced good negative ion CID spectra but those adducted with iodide and sulfate did not yield fragment ions although they gave stronger signals. Fragmentation paralleled that seen following electrospray ionization providing superior spectra than could be obtained by PSD on MALDI-TOF instruments or with ion traps. In addition, ion mobility drift times of the adducted glycans and the ability of this technique to separate isomers also mirrored those obtained following ESI sample introduction. Ion mobility also allowed profiles to be obtained from samples whose MALDI spectra showed no evidence of such ions allowing the technique to be used in conditions where sample amounts were limiting. The method was applied to N-glycans released from the recombinant human immunodeficiency virus glycoprotein, gp120.

  9. Comprehensive characterization of well-defined silk fibroin surfaces: Toward multitechnique studies of surface modification effects.

    PubMed

    Amornsudthiwat, Phakdee; Nitschke, Mirko; Zimmermann, Ralf; Friedrichs, Jens; Grundke, Karina; Pöschel, Kathrin; Damrongsakkul, Siriporn; Werner, Carsten

    2015-06-21

    The study aims at a comprehensive surface characterization of untreated and oxygen plasma-treated silk fibroin with a particular focus on phenomena relevant to biointeraction and cell adhesion. For that purpose, a range of advanced surface diagnostic techniques is employed to thoroughly investigate well-defined and especially clean silk fibroin samples in a comparable setting. This includes surface chemistry and surface charges as factors, which control protein adsorption, but also hydration and swelling of the material as important parameters, which govern the mechanical stiffness at the interface with aqueous media. Oxygen plasma exposure of silk fibroin surfaces reveals that material ablation strongly predominates over the introduction of functional groups even for mild plasma conditions. A substantial increase in mechanical stiffness is identified as the most prominent effect upon this kind of plasma treatment. Regarding the experimental approach and the choice of techniques, the work goes beyond previous studies in this field and paves the way for well-founded investigations of other surface-selective modification procedures that enhance the applicability of silk fibroin in biomedical applications.

  10. Fluorescence correlation spectroscopy: principles and applications.

    PubMed

    Bacia, Kirsten; Haustein, Elke; Schwille, Petra

    2014-07-01

    Fluorescence correlation spectroscopy (FCS) is used to study the movements and the interactions of biomolecules at extremely dilute concentrations, yielding results with good spatial and temporal resolutions. Using a number of technical developments, FCS has become a versatile technique that can be used to study a variety of sample types and can be advantageously combined with other methods. Unlike other fluorescence-based techniques, the analysis of FCS data is not based on the average intensity of the fluorescence emission but examines the minute intensity fluctuations caused by spontaneous deviations from the mean at thermal equilibrium. These fluctuations can result from variations in local concentrations owing to molecular mobility or from characteristic intermolecular or intramolecular reactions of fluorescently labeled biomolecules present at low concentrations. Here, we provide a basic introduction to FCS, including its technical development and theoretical basis, experimental setup of an FCS system, adjustment of a setup, data acquisition, and analysis of FCS measurements. Finally, the application of FCS to the study of lipid bilayer membranes and to living cells is discussed. © 2014 Cold Spring Harbor Laboratory Press.

  11. Mixed infections in tuberculosis: The missing part in a puzzle.

    PubMed

    Tarashi, Samira; Fateh, Abolfazl; Mirsaeidi, Mehdi; Siadat, Seyed Davar; Vaziri, Farzam

    2017-12-01

    The mixed strains infection phenomenon is a major problem posing serious challenges in control of tuberculosis (TB). In patients with mixed infection, several different strains of Mycobacterium tuberculosis can be isolated simultaneously. Although different genotyping methods and various molecular approaches can be employed for detection of mixed infection in clinical samples, the MIRU-VNTR technique is more sensitive with higher discriminative power than many widely used techniques. Furthermore, the recent introduction of whole genome sequencing (WGS) promises to reveal more details about mixed infection with high resolution. WGS has been used for detection of mixed infection with high sensitivity and discriminatory, but the technology is currently limited to developed countries. Mixed infection may involve strains with different susceptibility patterns, which may alter the treatment outcome. In this report, we review the current concepts of mixed strains infection and also infection involving strains with a different susceptibility pattern in TB. We evaluate the importance of identifying mixed infection for diagnosis as well as treatment and highlight the accuracy and clinical utility of direct genotyping of clinical specimens. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Attempt to form hydride and amorphous particles, and introduction of a new evaporation method

    NASA Astrophysics Data System (ADS)

    Yatsuya, S.; Yamauchi, K.; Kamakura, T.; Yanagida, A.; Wakayama, H.; Mihama, K.

    1985-06-01

    Al and TiH 2 particles of fcc structure can be produced in an atmosphere of gaseous H 2 at reduced pressure. Al particles with definite habit are obtained, which has been never observed in the ordinary gas evaporation technique using a HV system. The habit of TiH 2 particles grown in the intermediate zone of the smoke is determined to be a dodecahedron. The growth is considered as the result of the martensite transformation from the bcc structure initially formed to the fcc structure accompanying a slight modification of the characteristic habit as observed for Ti particles. For the preparation of amorphous particles, first, the quenching rate of a particle, {dT}/{dt} was estimated to be more than {10 4°C }/{s}. Ultrafine particles of Pd 80Si 20 chosen as a test sample did not show the amorphous structure, but the crystalline. Application of the sputtering method as a new evaporation source in the gas evaporation technique is attempted. With the sputtering method, W particles with definite habits are produced.

  13. The determination of trace elements in crude oil and its heavy fractions by atomic spectrometry

    NASA Astrophysics Data System (ADS)

    Duyck, Christiane; Miekeley, Norbert; Porto da Silveira, Carmem L.; Aucélio, Ricardo Q.; Campos, Reinaldo C.; Grinberg, Patrícia; Brandão, Geisamanda P.

    2007-09-01

    A literature review on the determination of trace elements in crude oil and heavy molecular mass fractions (saturates, aromatics, resins and asphaltenes) by ICP-MS, ICP OES and AAS is presented. Metal occurrences, forms and distributions are examined as well as their implications in terms of reservoir geochemistry, oil refining and environment. The particular analytical challenges for the determination of metals in these complex matrices by spectrochemical techniques are discussed. Sample preparation based on ashing, microwave-assisted digestion and combustion decomposition procedures is noted as robust and long used. However, the introduction of non-aqueous solvents and micro-emulsions into inductively coupled plasmas is cited as a new trend for achieving rapid and accurate analysis. Separation procedures for operationally defined fractions in crude oil are more systematically applied for the observation of metal distributions and their implications. Chemical speciation is of growing interest, achieved by the coupling of high efficiency separation techniques (e.g., HPLC and GC) to ICP-MS instrumentation, which allows the simultaneous determination of multiple organometallic species of geochemical and environmental importance.

  14. Isotope ratio analysis of individual sub-micrometer plutonium particles with inductively coupled plasma mass spectrometry.

    PubMed

    Esaka, Fumitaka; Magara, Masaaki; Suzuki, Daisuke; Miyamoto, Yutaka; Lee, Chi-Gyu; Kimura, Takaumi

    2010-12-15

    Information on plutonium isotope ratios in individual particles is of great importance for nuclear safeguards, nuclear forensics and so on. Although secondary ion mass spectrometry (SIMS) is successfully utilized for the analysis of individual uranium particles, the isobaric interference of americium-241 to plutonium-241 makes difficult to obtain accurate isotope ratios in individual plutonium particles. In the present work, an analytical technique by a combination of chemical separation and inductively coupled plasma mass spectrometry (ICP-MS) is developed and applied to isotope ratio analysis of individual sub-micrometer plutonium particles. The ICP-MS results for individual plutonium particles prepared from a standard reference material (NBL SRM-947) indicate that the use of a desolvation system for sample introduction improves the precision of isotope ratios. In addition, the accuracy of the (241)Pu/(239)Pu isotope ratio is much improved, owing to the chemical separation of plutonium and americium. In conclusion, the performance of the proposed ICP-MS technique is sufficient for the analysis of individual plutonium particles. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Evidence-Based Medicine: Liposuction.

    PubMed

    Chia, Christopher T; Neinstein, Ryan M; Theodorou, Spero J

    2017-01-01

    After studying this article, the participant should be able to: 1. Review the appropriate indications and techniques for suction-assisted lipectomy body contouring surgery. 2. Accurately calculate the patient limits of lidocaine for safe dosing during the tumescent infiltration phase of liposuction. 3. Determine preoperatively possible "red flags" or symptoms and signs in the patient history and physical examination that may indicate a heightened risk profile for a liposuction procedure. 4. Provide an introduction to adjunctive techniques to liposuction such as energy-assisted liposuction and to determine whether or not the reader may decide to add them to his or her practice. With increased focus on one's aesthetic appearance, liposuction has become the most popular cosmetic procedure in the world since its introduction in the 1980s. As it has become more refined with experience, safety, patient selection, preoperative assessment, fluid management, proper technique, and overall care of the patient have been emphasized and improved. For the present article, a systematic review of the relevant literature regarding patient workup, tumescent fluid techniques, medication overview, and operative technique was conducted with a practical approach that the reader will possibly find clinically applicable. Recent trends regarding energy-assisted liposuction and body contouring local anesthesia use are addressed. Deep venous thromboembolism prophylaxis is mentioned, as are other common and less common possible complications. The article provides a literature-supported overview on liposuction techniques with an emphasis on preoperative assessment, medicines used, operative technique, and outcomes.

  16. Evaluation of ammonia as diluent for serum sample preparation and determination of selenium by graphite furnace atomic absorption spectrometry*1

    NASA Astrophysics Data System (ADS)

    Hernández-Caraballo, Edwin A.; Burguera, Marcela; Burguera, José L.

    2002-12-01

    A method for the determination of total selenium in serum samples by graphite furnace atomic absorption spectrometry was evaluated. The method involved direct introduction of 1:5 diluted serum samples (1% v/v NH 4OH+0.05% w/v Triton X-100 ®) into transversely heated graphite tubes, and the use of 10 μg Pd+3 μg Mg(NO 3) 2 as chemical modifier. Optimization of the modifier mass and the atomization temperature was conducted by simultaneously varying such parameters and evaluating both the integrated absorbance and the peak height/peak area ratio. The latter allowed the selection of compromise conditions rendering good sensitivity and adequate analyte peak profiles. A characteristic mass of 49 pg and a detection limit (3s) of 6 μg 1 -1 Se, corresponding to 30 μg l -1 Se in the serum sample, were obtained. The analyte addition technique was used for calibration. The accuracy was assessed by the determination of total selenium in Seronorm™ Trace Elements Serum Batch 116 (Nycomed Pharma AS). The method was applied for the determination of total selenium in ten serum samples taken from individuals with no known physical affection. The selenium concentration ranged between 79 and 147 μg l -1, with a mean value of 114±22 μg l -1.

  17. First- and second-trimester WIC participation is associated with lower rates of breastfeeding and early introduction of cow's milk during infancy.

    PubMed

    Ziol-Guest, Kathleen M; Hernandez, Daphne C

    2010-05-01

    Existing literature suggests prenatal participation in the Special Supplemental Nutrition Program for Women, Infants, and Children (WIC) may reduce breastfeeding among low-income mothers. However, little is known about whether the timing of WIC entrance during pregnancy influences infant feeding decisions. This study assesses the association between the timing of prenatal participation in WIC and various infant feeding practices, including breastfeeding initiation, breastfeeding for at least 4 months, exclusive breastfeeding, formula feeding, and early introduction of cow's milk and solid food. Cross-sectional survey matching of birth certificate data to mothers' interviews 9 months after the child's birth. Mothers provided information on participation in the WIC program, infant feeding practices, and sociodemographic characteristics. A nationally representative sample of 4,450 births in 2001 from the Early Childhood Longitudinal Survey-Birth Cohort. Multivariate logistic regression techniques (using STATA 9.0 SE, Stata Company, College Station, TX) estimated the relationship between the timing of prenatal WIC participation and infant feeding practices. Entry into the WIC program during the first or second trimester of pregnancy is associated with reduced likelihood of initiation of breastfeeding and early cow's milk introduction; and entry during the first trimester is associated with reduced duration of breastfeeding. WIC participation at any trimester is positively related to formula feeding. Prenatal WIC participation is associated with a greater likelihood of providing babies infant formula rather than breastmilk after birth. Findings also indicate that there are critical prenatal periods for educating women about the health risks of early cow's milk introduction. Given the health implications of feeding infants cow's milk too early, WIC may be successful in educating women on the health risks of introducing complementary foods early, even if direct counseling on cow's milk is not provided. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  18. Hydrodynamic injection with pneumatic valving for microchip electrophoresis with total analyte utilization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Xuefei; Kelly, Ryan T.; Danielson, William F.

    2011-04-26

    A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip capillary electrophoresis (CE) separations. The poly(dimethylsiloxane) (PDMS) devices used for evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersectionmore » geometry, the solution back pressure and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to >2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4 cm long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, no sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations, for multiplexing CE separations and for sample-limited bioanalyses are discussed.« less

  19. What's the Matter with Waves?; An introduction to techniques and applications of quantum mechanics

    NASA Astrophysics Data System (ADS)

    Parkinson, William

    2017-12-01

    Like rocket science or brain surgery, quantum mechanics is pigeonholed as a daunting and inaccessible topic, which is best left to an elite or peculiar few. This classification was not earned without some degree of merit. Depending on perspective; quantum mechanics is a discipline or philosophy, a convention or conundrum, an answer or question. Authors have run the gamut from hand waving to heavy handed in the hope to dispel the common beliefs about quantum mechanics, but perhaps they continue to promulgate the stigma. The focus of this particular effort is to give the reader an introduction, if not at least an appreciation, of the role that linear algebra techniques play in the practical application of quantum mechanical methods. It interlaces aspects of the classical and quantum picture, including a number of both worked and parallel applications. Students with no prior experience in quantum mechanics, motivated graduate students, or researchers in other areas attempting to gain some introduction to quantum theory will find particular interest in this book. Part of Series on wave phenomena in the physical sciences

  20. Efficacy of Different Methods for Removing Root Canal Filling Material in Retreatment - An In-vitro Study

    PubMed Central

    Mariswamy, Annapoorna Ballagere

    2016-01-01

    Introduction Although success of endodontic therapy has significantly improved in the last few decades due to the introduction of novel materials and techniques, failures of endodontic therapy requiring re-treatment still comprise a significant percentage of patients requiring root canal treatment. Aim To evaluate and compare the effective removal of gutta percha and sealer, amount of apical debris extrusion and time required for gutta percha removal using various endodontic files. Materials and Methods Total 48 extracted mandibular premolars were mounted on acrylic blocks and endodontic procedure was carried out using size 40 K file and obturated using guttapercha and zinc oxide eugenol sealer. After one month storage, samples were decoronated, mounted on screw capped vials and subjected to removal of obturated material by four instruments: H files, safe sided H files, protaper universal retreatment rotary system and ultrasonic retreatment tip, grouped as 1, 2, 3, and 4 respectively. Only 2mm of obturated material from the coronal part was removed using no. 3 Gates Glidden drill, guttapercha was softened with a drop of xylene for 2 mins for each canal and retreatment was performed. The retreatment procedure was said to be complete when no visible debris were observed on the instrument flutes. The samples split into two halves and examined under stereomicroscope, photographed, assessed using AUTOCAD software and percentage of remaining filling material in coronal, middle, apical thirds of the canal was calculated in mm2. Retreatment time was recorded in seconds and apically extruded debris was assessed by microbalance in grams for each tooth. The data was analyzed by using descriptive statistics, ANOVA and Scheffe’s post hoc test through SPSS for windows (v 16.0). Results The ultrasonic retreatment tip had less percentage of residual guttapercha/sealer, shorter mean operating time and little apical extrusion with a significant difference (p<0.05) between the other groups. Conclusion All techniques retained guttapercha/sealer remnants within the root canal. The ultrasonic retreatment tip proved to be an efficient method of removing obturated material. It was fastest with least apical debris extrusion. PMID:27504397

  1. Elementary Introduction to the Green's Function

    ERIC Educational Resources Information Center

    Whitten, R. C.; McCormick, P. T.

    1975-01-01

    Presents a technique, using the method of variation of parameters for solving differential equations, for introducing Green's function early in an undergraduate curriculum. Presents various examples. (Author/MLH)

  2. A Decade of Change: An Institutional Experience with Breast Surgery in 1995 and 2005

    PubMed Central

    Guth, Amber A.; Shanker, Beth Ann; Roses, Daniel F.; Axelrod, Deborah; Singh, Baljit; Toth, Hildegard; Shapiro, Richard L.; Hiotis, Karen; Diflo, Thomas; Cangiarella, Joan F.

    2008-01-01

    Introduction: With the adoption of routine screening mammography, breast cancers are being diagnosed at earlier stages, with DCIS now accouting for 22.5% of all newly diagnosed breast cancers. This has been attributed to both increased breast cancer awareness and improvements in breast imaging techniques. How have these changes, including the increased use of image-guided sampling techniques, influenced the clinical practice of breast surgery? Methods: The institutional pathology database was queried for all breast surgeries, including breast reconstruction, performed in 1995 and 2005. Cosmetic procedures were excluded. The results were analysed utilizing the Chi-square test. Results: Surgical indications changed during 10-year study period, with an increase in preoperatively diagnosed cancers undergoing definitive surgical management. ADH, and to a lesser extent, ALH, became indications for surgical excision. Fewer surgical biopsies were performed for indeterminate abnormalities on breast imaging, due to the introduction of stereotactic large core biopsy. While the rate of benign breast biopsies remained constant, there was a higher percentage of precancerous and DCIS cases in 2005. The overall rate of mastectomy decreased from 36.8% in 1995 to 14.5% in 2005. With the increase in sentinel node procedures, the rate of ALND dropped from 18.3% to 13.7%. Accompanying the increased recognition of early-stage cancers, the rate of positive ALND also decreased, from 43.3% to 25.0%. Conclusions: While the rate of benign breast biopsies has remained constant over a recent 10-year period, fewer diagnostic surgical image-guided biopsies were performed in 2005. A greater percentage of patients with breast cancer or preinvasive disease have these diagnoses determined before surgery. More preinvasive and Stage 0 cancers are undergoing surgical management. Earlier stage invasive cancers are being detected, reflected by the lower incidence of axillary nodal metastases. PMID:21655372

  3. Introduction to digital PCR.

    PubMed

    Bizouarn, Francisco

    2014-01-01

    Digital PCR (dPCR) is a molecular biology technique going through a renaissance. With the arrival of new instrumentation dPCR can now be performed as a routine molecular biology assay. This exciting new technique provides quantitative and detection capabilities that by far surpass other methods currently used. This chapter is an overview of some of the applications currently being performed using dPCR as well as the fundamental concepts and techniques this technology is based on.

  4. Integrated Data and Control Level Fault Tolerance Techniques for Signal Processing Computer Design

    DTIC Science & Technology

    1990-09-01

    TOLERANCE TECHNIQUES FOR SIGNAL PROCESSING COMPUTER DESIGN G. Robert Redinbo I. INTRODUCTION High-speed signal processing is an important application of...techniques and mathematical approaches will be expanded later to the situation where hardware errors and roundoff and quantization noise affect all...detect errors equal in number to the degree of g(X), the maximum permitted by the Singleton bound [13]. Real cyclic codes, primarily applicable to

  5. acdc – Automated Contamination Detection and Confidence estimation for single-cell genome data

    DOE PAGES

    Lux, Markus; Kruger, Jan; Rinke, Christian; ...

    2016-12-20

    A major obstacle in single-cell sequencing is sample contamination with foreign DNA. To guarantee clean genome assemblies and to prevent the introduction of contamination into public databases, considerable quality control efforts are put into post-sequencing analysis. Contamination screening generally relies on reference-based methods such as database alignment or marker gene search, which limits the set of detectable contaminants to organisms with closely related reference species. As genomic coverage in the tree of life is highly fragmented, there is an urgent need for a reference-free methodology for contaminant identification in sequence data. We present acdc, a tool specifically developed to aidmore » the quality control process of genomic sequence data. By combining supervised and unsupervised methods, it reliably detects both known and de novo contaminants. First, 16S rRNA gene prediction and the inclusion of ultrafast exact alignment techniques allow sequence classification using existing knowledge from databases. Second, reference-free inspection is enabled by the use of state-of-the-art machine learning techniques that include fast, non-linear dimensionality reduction of oligonucleotide signatures and subsequent clustering algorithms that automatically estimate the number of clusters. The latter also enables the removal of any contaminant, yielding a clean sample. Furthermore, given the data complexity and the ill-posedness of clustering, acdc employs bootstrapping techniques to provide statistically profound confidence values. Tested on a large number of samples from diverse sequencing projects, our software is able to quickly and accurately identify contamination. Results are displayed in an interactive user interface. Acdc can be run from the web as well as a dedicated command line application, which allows easy integration into large sequencing project analysis workflows. Acdc can reliably detect contamination in single-cell genome data. In addition to database-driven detection, it complements existing tools by its unsupervised techniques, which allow for the detection of de novo contaminants. Our contribution has the potential to drastically reduce the amount of resources put into these processes, particularly in the context of limited availability of reference species. As single-cell genome data continues to grow rapidly, acdc adds to the toolkit of crucial quality assurance tools.« less

  6. Rapid and highly reproducible analysis of rare earth elements by multiple collector inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Baker, Joel; Waight, Tod; Ulfbeck, David

    2002-10-01

    A method has been developed for the rapid chemical separation and highly reproducible analysis of the rare earth elements (REE) by isotope dilution analysis by means of a multiple collector inductively coupled plasma mass spectrometer (MC-ICP-MS). This technique is superior in terms of the analytical reproducibility or rapidity of analysis compared with quadrupole ICP-MS or with thermal ionization mass spectrometric isotope dilution techniques. Samples are digested by standard hydrofluoric-nitric acid-based techniques and spiked with two mixed spikes. The bulk REE are separated from the sample on a cation exchange column, collecting the middle-heavy and light REE as two groups, which provides a middle-heavy REE cut with sufficient separation of the light from the heavier REE to render oxide interferences trivial, and a Ba-free light REE cut. The heavy (Er-Lu), middle (Eu-Gd), and light REE (La-Eu) concentrations are determined by three short (1 to 2 min) analyses with a CETAC Aridus desolvating nebulizer introduction system. Replicate digestions of international rock standards demonstrate that concentrations can be reproduced to <1%, which reflects weighing errors during digestion and aliquotting as inter-REE ratios reproduce to ≤0.2% (2 SD). Eu and Ce anomalies reproduce to <0.15%. In addition to determining the concentrations of polyisotopic REE by isotope dilution analysis, the concentration of monoisotopic Pr can be measured during the light REE isotope dilution run, by reference to Pr/Ce and Pr/Nd ratios measured in a REE standard solution. Pr concentrations determined in this way reproduce to <1%, and Pr/REE ratios reproduce to <0.4%. Ce anomalies calculated with La and Pr also reproduce to <0.15% (2 SD). The precise Ce (and Eu) anomaly measurements should allow greater use of these features in studying the recycling of materials with these anomalies into the mantle, or redox-induced effects on the REE during recycling and dehydration of oceanic lithosphere, partial melting, metamorphism, alteration, or sedimentation processes. Moreover, this technique consumes very small amounts (subnanograms) of the REE and will allow precise REE determinations to be made on much smaller samples than hitherto possible.

  7. acdc – Automated Contamination Detection and Confidence estimation for single-cell genome data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lux, Markus; Kruger, Jan; Rinke, Christian

    A major obstacle in single-cell sequencing is sample contamination with foreign DNA. To guarantee clean genome assemblies and to prevent the introduction of contamination into public databases, considerable quality control efforts are put into post-sequencing analysis. Contamination screening generally relies on reference-based methods such as database alignment or marker gene search, which limits the set of detectable contaminants to organisms with closely related reference species. As genomic coverage in the tree of life is highly fragmented, there is an urgent need for a reference-free methodology for contaminant identification in sequence data. We present acdc, a tool specifically developed to aidmore » the quality control process of genomic sequence data. By combining supervised and unsupervised methods, it reliably detects both known and de novo contaminants. First, 16S rRNA gene prediction and the inclusion of ultrafast exact alignment techniques allow sequence classification using existing knowledge from databases. Second, reference-free inspection is enabled by the use of state-of-the-art machine learning techniques that include fast, non-linear dimensionality reduction of oligonucleotide signatures and subsequent clustering algorithms that automatically estimate the number of clusters. The latter also enables the removal of any contaminant, yielding a clean sample. Furthermore, given the data complexity and the ill-posedness of clustering, acdc employs bootstrapping techniques to provide statistically profound confidence values. Tested on a large number of samples from diverse sequencing projects, our software is able to quickly and accurately identify contamination. Results are displayed in an interactive user interface. Acdc can be run from the web as well as a dedicated command line application, which allows easy integration into large sequencing project analysis workflows. Acdc can reliably detect contamination in single-cell genome data. In addition to database-driven detection, it complements existing tools by its unsupervised techniques, which allow for the detection of de novo contaminants. Our contribution has the potential to drastically reduce the amount of resources put into these processes, particularly in the context of limited availability of reference species. As single-cell genome data continues to grow rapidly, acdc adds to the toolkit of crucial quality assurance tools.« less

  8. Marginal accuracy of nickel chromium copings fabricated by conventional and accelerated casting procedures, produced with ringless and metal ring investment procedures: A comparative in vitro study

    PubMed Central

    Alex, Deepa; Shetty, Y. Bharath; Miranda, Glynis Anita; Prabhu, M. Bharath; Karkera, Reshma

    2015-01-01

    Background: Conventional investing and casting techniques are time-consuming and usually requires 2–4 h for completion. Accelerated nonstandard, casting techniques have been reported to achieve similar quality results in significantly less time, namely, in 30–40 min. During casting, it is essential to achieve compensation for the shrinkage of solidifying alloy by investment expansion. The metal casting ring restricts the thermal expansion of investment because the thermal expansion of the ring is lesser than that of the investment. The use of casting ring was challenged with the introduction of the ringless technique. Materials and Methods: A total of 40 test samples of nickel chromium (Ni-Cr) cast copings were obtained from the patterns fabricated using inlay casting wax. The 20 wax patterns were invested using metal ring and 20 wax patterns were invested using the ringless investment system. Of both the groups, 10 samples underwent conventional casting, and the other 10 underwent accelerated casting. The patterns were casted using the induction casting technique. All the test samples of cast copings were evaluated for vertical marginal gaps at four points on the die employing a stereo optical microscope. Results: The vertical marginal discrepancy data obtained were tabulated. Mean and standard deviations were obtained. Vertical discrepancies were analyzed using analysis of variance and Tukey honestly significantly different. The data obtained were found to be very highly significant (P < 0.001). Mean vertical gap was the maximum for Group II (53.64 μm) followed by Group IV (47.62 μm), Group I (44.83 μm) and Group III (35.35 μm). Conclusion: The Ni-Cr cast copings fabricated with the conventional casting using ringless investment system showed significantly better marginal fit than that of cast copings fabricated from conventional and accelerated casting with metal ring investment and accelerated casting using ringless investment since those copings had shown the least vertical marginal discrepancies among the four methods evaluated in this study. PMID:26929488

  9. Corrosion behavior of HPT-deformed TiNi alloys in cell culture medium

    NASA Astrophysics Data System (ADS)

    Shri, D. N. Awang; Tsuchiya, K.; Yamamoto, A.

    2017-09-01

    In recent years there are growing interest in fabrication of bulk nanostructured metals and alloys by using severe plastic deformation (SPD) techniques as new alternative in producing bulk nanocrystalline materials. These techniques allows for processing of bulk, fully dense workpiece with ultrafine grains. Metal undergoes SPD processing in certain techniques such as high pressure torsion (HPT), equal-channel angular pressing (ECAP) or multi-directional forging (MDF) are subjected to extensive hydrostatic pressure that may be used to impart a very high strain to the bulk solid without the introduction of any significant change in overall dimension of the sample. The change in the structure (small grain size and high-volume fraction of grain boundaries) of the material may result in the corrosion behavior different from that of the coarse-grained material. Electrochemical measurements were done to understand the corrosion behavior of TiNi alloys before and after HPT deformation. The experiment was carried out using standard three electrode setup (a sample as working electrode; a platinum wire as a counter electrode and a saturated calomel electrode in saturated KCl as a reference electrode) with the surface area of 26.42 mm2 exposed to the EMEM+10% FBS cell culture medium. The measurements were performed in an incubator with controlled environment at 37 °C and 5% CO2, simulating the cell culture condition. The potential of the specimen was monitored over 1 hour, and the stabilized potential was used as the open-circuit potential (EOCP). Potentiodynamic curves were scanned in the potential range from -0.5 V to 1.5 V relative to the EOCP, at a rate of 0.5 mV/s. The result of OCP-time measurement done in the cell culture medium shows that the OCP of HPT-deformed samples shifts towards to the more positive rather than that of BHPT samples. The OCP of deformed samples were ennobled to more than +70 mV for Ti-50mol%. The shift of OCP towards the nobler direction indicates the passive nature of native oxides formed on the surface of the samples. The polarization curve, on the other hand, indicates that the HPT deformation was found to shift the passive current to nobler region. The passive region current density is found to be lower than that of the BHPT, suggesting the passive film formed on the surface of HPT-deformed samples is more protective than that of the BHPT sample. This study has shown that nanocrystallization and amorphization induced by severe plastic deformation change the corrosion behavior of TiNi alloys.

  10. Effect of bisecting GlcNAc and core fucosylation on conformational properties of biantennary complex-type N-glycans in solution.

    PubMed

    Nishima, Wataru; Miyashita, Naoyuki; Yamaguchi, Yoshiki; Sugita, Yuji; Re, Suyong

    2012-07-26

    The introduction of bisecting GlcNAc and core fucosylation in N-glycans is essential for fine functional regulation of glycoproteins. In this paper, the effect of these modifications on the conformational properties of N-glycans is examined at the atomic level by performing replica-exchange molecular dynamics (REMD) simulations. We simulate four biantennary complex-type N-glycans, namely, unmodified, two single-substituted with either bisecting GlcNAc or core fucose, and disubstituted forms. By using REMD as an enhanced sampling technique, five distinct conformers in solution, each of which is characterized by its local orientation of the Manα1-6Man glycosidic linkage, are observed for all four N-glycans. The chemical modifications significantly change their conformational equilibria. The number of major conformers is reduced from five to two and from five to four upon the introduction of bisecting GlcNAc and core fucosylation, respectively. The population change is attributed to specific inter-residue hydrogen bonds, including water-mediated ones. The experimental NMR data, including nuclear Overhauser enhancement and scalar J-coupling constants, are well reproduced taking the multiple conformers into account. Our structural model supports the concept of "conformer selection", which emphasizes the conformational flexibility of N-glycans in protein-glycan interactions.

  11. Association of glass fragments by their trace elemental content using ICP-MS and LA-ICP-MS in the analysis scheme

    NASA Astrophysics Data System (ADS)

    Almirall, Jose R.; Montero, Shirly; Furton, Kenneth G.

    2002-08-01

    The importance of glass as evidence of association between a crime event and a suspect has been recognized for some time. Glass is a fragile material that is often found at the scenes of crimes such as burglaries, hit-and-run accidents and violent crime offenses. The physical and chemical properties of glass can be used to differentiate between possible sources and as evidence of association between two fragments of glass thought to originate from the same source. Refractive index (RI) comparisons have been used for this purpose but due to the improved control over glass manufacturing processes, RI values often cannot differentiate glasses, even if the glass originates from different sources. Elemental analysis methods such as NAA, XRF, ICP-AES, and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) have also been used for the comparison of trace elemental compositions and these techniques have been shown to provide an improvement in the discrimination of glass fragments over RI comparisons alone. The multi-element capability and the sensitivity of ICP-MS combined with the simplified sample introduction of laser ablation prior to ion detection provides for an excellent and relatively non-destructive technique for elemental analysis of glass fragments. The methodology for solution analysis (digestion procedure) and solid sample analysis (laser ablation) of glass is reported and the analytical results are compared. An isotope dilution method is also reported as a high precision technique for elemental analysis of glass fragments. The optimum sampling parameters for laser ablation, for semi-quantitative analysis and element ratio comparisons are also presented. Finally, the results of a case involving the breaking of 15 vehicle windows in an airport parking lot and the association of a suspect to the breakings by the glass fragments found on his person are also presented.

  12. MicroRNAs derived from circulating exosomes as non-invasive biomarkers for screening and diagnose lung cancer

    PubMed Central

    Cazzoli, Riccardo; Buttitta, Fiamma; Di Nicola, Marta; Malatesta, Sara; Marchetti, Antonio; Pass, Harvey I.

    2013-01-01

    Introduction Lung cancer is formerly the highest cause of mortality among tumor pathologies worldwide. There are no validated techniques for an early detection of pulmonary cancer lesions other than low-dose helical CT-scan. Unfortunately, this method have some downside effects. Recent studies have laid the basis for development of exosomes-based techniques to screen/diagnose lung cancers. As the isolation of circulating exosomes is a minimally invasive procedure, this technique opens new possibilities for diagnostic applications. Methods We used a first set of 30 plasma samples from as many patients, including 10 patients affected by Lung Adenocarcinomas, 10 with Lung Granulomas and 10 healthy smokers matched for age and sex as negative controls. Wide range microRNAs analysis (742 microRNAs) was performed by quantitative RT-PCR. Data were compared by lesion characteristics using WEKA software for statistics and modeling. Subsequently, selected microRNAs were evaluated on an independent larger group of samples (105 specimens: 50 Lung Adenocarcinomas, 30 Lung Granulomas and 25 healthy smokers). Results This analysis led to the selection of 4 microRNAs to perform a screening test (miR-378a, miR-379, miR-139-5p and miR-200b-5p), useful to divide population into 2 groups: nodule (lung adenocarcinomas+carcinomas) and non-nodule (healthy former smokers). Six microRNAs (miR-151a-5p, miR-30a-3p, miR-200b-5p, miR-629, miR-100 and miR-154-3p) were selected for a second test on the “nodule” population to discriminate between lung adenocarcinoma and granuloma. Conclusions “Screening test” has shown 97.5% sensitivity, 72.0% specificity, AUC ROC of 90.8%. “Diagnostic test” had 96.0% sensitivity, 60.0% specificity, AUC ROC of 76.0%. Further evaluation is needed to confirm the predictive power of those models on higher cohorts of samples. PMID:23945385

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, Audrey Noreen

    Homeland security relies heavily on analytical chemistry to identify suspicious materials and persons. Traditionally this role has focused on attribution, determining the type and origin of an explosive, for example. But as technology advances, analytical chemistry can and will play an important role in the prevention and preemption of terrorist attacks. More sensitive and selective detection techniques can allow suspicious materials and persons to be identified even before a final destructive product is made. The work presented herein focuses on the use of commercial and novel detection techniques for application to the prevention of terrorist activities. Although drugs are notmore » commonly thought of when discussing terrorism, narcoterrorism has become a significant threat in the 21st century. The role of the drug trade in the funding of terrorist groups is prevalent; thus, reducing the trafficking of illegal drugs can play a role in the prevention of terrorism by cutting off much needed funding. To do so, sensitive, specific, and robust analytical equipment is needed to quickly identify a suspected drug sample no matter what matrix it is in. Single Particle Aerosol Mass Spectrometry (SPAMS) is a novel technique that has previously been applied to biological and chemical detection. The current work applies SPAMS to drug analysis, identifying the active ingredients in single component, multi-component, and multi-tablet drug samples in a relatively non-destructive manner. In order to do so, a sampling apparatus was created to allow particle generation from drug tablets with on-line introduction to the SPAMS instrument. Rules trees were developed to automate the identification of drug samples on a single particle basis. A novel analytical scheme was also developed to identify suspect individuals based on chemical signatures in human breath. Human breath was sampled using an RTube{trademark} and the trace volatile organic compounds (VOCs) were preconcentrated using solid phase microextraction (SPME) and identified using gas chromatography - mass spectrometry (GC-MS). Modifications to the sampling apparatus allowed for increased VOC collection efficiency, and reduced the time of sampling and analysis by over 25%. The VOCs are present in breath due to either endogenous production, or exposure to an external source through absorption, inhalation, or ingestion. Detection of these exogenous chemicals can provide information on the prior location and activities of the subject. Breath samples collected before and after exposure in a hardware store and nail salon were analyzed to investigate the prior location of a subject; breath samples collected before and after oral exposure to terpenes and terpenoid compounds, pseudoephedrine, and inhalation exposure to hexamine and other explosive related compounds were analyzed to investigate the prior activity of a subject. The elimination of such compounds from the body was also monitored. In application, this technique may provide an early warning system to identify persons of interest in the prevention and preemption stages of homeland security.« less

  14. Illuminating the Past: The Neutron as a Tool in Archaeology

    ERIC Educational Resources Information Center

    Kockelmann, W.; Kirfel, A.; Siano, S.; Frost, C. D.

    2004-01-01

    Neutrons can be produced in nuclear reactions and used as very versatile probes for condensed matter research. Since their introduction in the 1950s neutron scattering techniques have evolved to be very powerful tools for investigating the properties of condensed matter. Here we present the concept of neutron diffraction and how this technique can…

  15. 4-H Alumni: Techniques and Strategies of Identifying and Involving 4-H Alumni.

    ERIC Educational Resources Information Center

    Reese, Cheryl C.

    Techniques and strategies of identifying and involving 4-H alumni are discussed and described via a model of the Tennessee 4-H Alumni, Inc., which began in 1975. Following an introduction, the guide begins with a section on finding and organizing alumni which encompasses alumni organizers (organizational decisions, model alumni association);…

  16. [3-dimensional models of actual or simulated cesarean sections].

    PubMed

    Patzak, B; Schaller, A

    2001-01-01

    Following upon an etymological and historical introduction, this report refers to two three-dimensional wax models of Caesarean sections, which have recently been acquired by the Pathological-anatomical Federal Museum in Vienna. Information is given on origin, dating and kind of production; questions of indication and operation technique, and--when in doubt--obduction technique, are being considered.

  17. "On the Hurricane Deck of a Mule": Teaching Adults To Read Using Language-Experience and Oral History Techniques.

    ERIC Educational Resources Information Center

    Bear, Donald R.

    Designed to instruct adult literacy teachers in using Language-Experience and Oral History techniques and distributed statewide to teachers in Nevada, this manual presents reading materials, diagnostic packages, and guidelines for adult literacy program organization. The first of three chapters begins with an introduction to the manual, and…

  18. Introduction to computer image processing

    NASA Technical Reports Server (NTRS)

    Moik, J. G.

    1973-01-01

    Theoretical backgrounds and digital techniques for a class of image processing problems are presented. Image formation in the context of linear system theory, image evaluation, noise characteristics, mathematical operations on image and their implementation are discussed. Various techniques for image restoration and image enhancement are presented. Methods for object extraction and the problem of pictorial pattern recognition and classification are discussed.

  19. Multiple Alternatives for Educational Evaluation and Decision-Making. Interim Draft. Paper and Report Series No. 72.

    ERIC Educational Resources Information Center

    Wholeben, Brent E.

    This volume is an exposition of a mathematical modeling technique for use in the evaluation and solution of complex educational problems at all levels. It explores in detail the application of simple algebraic techniques to such issues as program reduction, fiscal rollbacks, and computer curriculum planning. Part I ("Introduction to the…

  20. Nuclear Technology. Course 26: Nondestructive Examination (NDE) Techniques I. Module 26-3, Hydrostatic Tests.

    ERIC Educational Resources Information Center

    Pelton, Rick; Espy, John

    This third in a series of seven modules for a course titled Nondestructive Examination (NDE) Techniques I describes the principles and practices associated with hydrostatic testing. The module follows a typical format that includes the following sections: (1) introduction, (2) module prerequisites, (3) objectives, (4) notes to instructor/student,…

  1. Employ Simulation Techniques. Second Edition. Module C-5 of Category C--Instructional Execution. Professional Teacher Education Module Series.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. National Center for Research in Vocational Education.

    One of a series of performance-based teacher education learning packages focusing upon specific professional competencies of vocational teachers, this learning module deals with employing simulation techniques. It consists of an introduction and four learning experiences. Covered in the first learning experience are various types of simulation…

  2. Research Methods and Techniques in Spanish Library and Information Science Journals (2012-2014)

    ERIC Educational Resources Information Center

    Ferran-Ferrer, Núria; Guallar, Javier; Abadal, Ernest; Server, Adan

    2017-01-01

    Introduction. This study examines the research methods and techniques used in Spanish journals of library and information science, the topics addressed by papers in these journals and their authorship affiliation. Method. The researchers selected 580 papers published in the top seven Spanish LIS journals indexed in Web of Science and Scopus and…

  3. Nuclear Technology. Course 32: Nondestructive Examination (NDE) Techniques II. Module 32-5, Fundamentals of Eddy Current Testing.

    ERIC Educational Resources Information Center

    Espy, John

    This fifth in a series of six modules for a course titled Nondestructive Examination (NDE) Techniques II describes the fundamental concepts applicable to eddy current testing in general. The module follows a typical format that includes the following sections: (1) introduction, (2) module prerequisites, (3) objectives, (4) notes to…

  4. Timing of Introduction of Complementary Foods to US Infants, National Health and Nutrition Examination Survey 2009-2014.

    PubMed

    Barrera, Chloe M; Hamner, Heather C; Perrine, Cria G; Scanlon, Kelley S

    2018-03-01

    Although there has been inconsistency in recommendations regarding the optimal time for introducing complementary foods, most experts agree that introduction should not occur before 4 months. Despite recommendations, studies suggest that 20% to 40% of US infants are introduced to foods at younger than 4 months. Previous studies focused on the introduction of solid foods and are not nationally representative. Our aims were to provide a nationally representative estimate of the timing of introduction of complementary foods and to describe predictors of early (<4 months) introduction. We conducted a cross-sectional analysis of 2009-2014 National Health and Nutrition Examination Survey data. The study included 1,482 children aged 6 to 36 months. Timing of first introduction to complementary foods (anything other than breast milk or formula) was analyzed. Prevalence estimates of first introduction to complementary foods are presented by month. Logistic regression was used to assess characteristics associated with early (<4 months) introduction. In this sample, 16.3% of US infants were introduced to complementary foods at <4 months, 38.3% between 4 and <6 months, 32.5% between 6 and <7 months, and 12.9% at ≥7 months of age. In unadjusted analyses, early introduction varied by breastfeeding status; race/Hispanic origin; Special Supplemental Nutrition Program for Women, Infants, and Children participation; and maternal age. In adjusted analyses, only breastfeeding status remained significant; infants who never breastfed or stopped at <4 months were more likely (odds ratio 2.27; 95% CI 1.62 to 3.18) to be introduced to complementary foods early than infants who breastfed ≥4 months. Despite using a broader definition of complementary foods, this analysis found a lower prevalence of early introduction in this nationally representative sample than previous studies that included only solids. However, many young children were still introduced to complementary foods earlier than recommended. Strategies to support caregivers to adhere to infant feeding guidelines may be needed. Copyright © 2018 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  5. Existing and emerging technologies for measuring stable isotope labelled retinol in biological samples: isotope dilution analysis of body retinol stores.

    PubMed

    Preston, Tom

    2014-01-01

    This paper discusses some of the recent improvements in instrumentation used for stable isotope tracer measurements in the context of measuring retinol stores, in vivo. Tracer costs, together with concerns that larger tracer doses may perturb the parameter under study, demand that ever more sensitive mass spectrometric techniques are developed. GCMS is the most widely used technique. It has high sensitivity in terms of sample amount and uses high resolution GC, yet its ability to detect low isotope ratios is limited by background noise. LCMSMS may become more accessible for tracer studies. Its ability to measure low level stable isotope tracers may prove superior to GCMS, but it is isotope ratio MS (IRMS) that has been designed specifically for low level stable isotope analysis through accurate analysis of tracer:tracee ratios (the tracee being the unlabelled species). Compound-specific isotope analysis, where GC is interfaced to IRMS, is gaining popularity. Here, individual 13C-labelled compounds are separated by GC, combusted to CO2 and transferred on-line for ratiometric analysis by IRMS at the ppm level. However, commercially-available 13C-labelled retinol tracers are 2 - 4 times more expensive than deuterated tracers. For 2H-labelled compounds, GC-pyrolysis-IRMS has now become more generally available as an operating mode on the same IRMS instrument. Here, individual compounds are separated by GC and pyrolysed to H2 at high temperature for analysis by IRMS. It is predicted that GC-pyrolysis-IRMS will facilitate low level tracer procedures to measure body retinol stores, as has been accomplished in the case of fatty acids and amino acids. Sample size requirements for GC-P-IRMS may exceed those of GCMS, but this paper discusses sample preparation procedures and predicts improvements, particularly in the efficiency of sample introduction.

  6. Chemical vapor generation sample introduction for the determination of As, Cd, Sb, Hg, and Pb in nail polish by inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Huang, Fan-Feng; Jiang, Shiuh-Jen; Chen, Yen-Ling; Sahayam, A. C.

    2018-02-01

    This paper describes a flow injection vapor generation (VG) method using inductively coupled plasma mass spectrometry (ICP-MS) for determining As, Cd, Sb, Hg, and Pb in nail polish. The samples for VG were prepared as aqueous slurries of a nail polish (0.5% m/v), thiourea (1% m/v), Co(II) (0.75 μg mL- 1), and HCl (1.2% v/v). Chemical VG of As, Cd, Sb, Hg, and Pb ions, by reduction with tetrahydroborate (3% m/v in 0.2% m/v NaOH), enabled their separation from the slurry. With VG sample introduction, As, Cd, Sb and Hg signals were increased by 1-2 orders (except Pb) compared to solution nebulization due to better sample introduction. Quantifications were performed by VG ICP-MS using isotope dilution and standard addition methods as slopes of calibration plots of analytes in the slurries were higher. Using the reported procedure, samples of three nail polishes purchased locally were analyzed for their levels of As, Cd, Sb, Hg, and Pb. The results obtained were in good agreement with those measured using electrothermal vaporization ICP-MS. In the original nail polish sample, the detection limits, calculated as 3σ of blank measurements, for As, Cd, Sb, Hg, and Pb, estimated from standard addition curves, were 0.06, 0.12, 0.14, 0.2, and 12 ng g- 1, respectively.

  7. Space Shuttle Program: STS-1 Medical Report

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The necessity for developing medical standards addressing individual classes of Shuttle crew positions is discussed. For the U.S. manned program the conclusion of the Apollo era heralded the end of water recovery operations and the introduction of land-based medical operations. This procedural change marked a significant departure from the accepted postflight medical recovery and evaluation techniques. All phases of the missions required careful re-evaluation, identification of potential impact on preexisting medical operational techniques, and development of new methodologies which were carefully evaluated and tested under simulated conditions. Significant coordination was required between the different teams involved in medical operations. Additional dimensions were added to the concepts of medical operations, by the introduction of different toxic substances utilized by the Space Transportation Systems especially during ground operations.

  8. On estimation in k-tree sampling

    Treesearch

    Christoph Kleinn; Frantisek Vilcko

    2007-01-01

    The plot design known as k-tree sampling involves taking the k nearest trees from a selected sample point as sample trees. While this plot design is very practical and easily applied in the field for moderate values of k, unbiased estimation remains a problem. In this article, we give a brief introduction to the...

  9. Age at Introduction to Solid Foods and Child Obesity at 6 Years.

    PubMed

    Barrera, Chloe M; Perrine, Cria G; Li, Ruowei; Scanlon, Kelley S

    2016-06-01

    Epidemiological evidence suggests that timing of introduction of solid foods may be associated with subsequent obesity, and the association may vary by whether an infant is breastfed or formula-fed. We included 1181 infants who participated in the Infant Feeding Practices Study II (IFPS II) and the Year 6 Follow Up (Y6FU) study. Data from IFPS II were used to calculate the primary exposure and timing of solid food introduction (<4, 4-<6, and ≥6 months), and data from Y6FU were used to calculate the primary outcome and obesity at 6 years of age (BMI ≥95th percentile). We used multivariable logistic regression to assess the association between timing of the introduction of solids and obesity at 6 years and test whether this association was modified by breastfeeding duration (breastfed for 4 months vs. not). Prevalence of obesity in our sample was 12.0%. The odds of obesity was higher among infants introduced to solids <4 months compared to those introduced at 4-<6 months (odds ratio [OR] = 1.66; 95% CI, 1.15, 2.40) in unadjusted analysis; however, this relationship was no longer significant after adjustment for covariates (OR = 1.18; 95% CI, 0.79, 1.77). Introduction of solids ≥6 months was not associated with obesity. We found no interaction between breastfeeding duration and early solid food introduction and subsequent obesity. Timing of introduction of solid foods was not associated with child obesity at 6 years in this sample. Given the inconsistency in findings with other studies, further studies in larger populations may be needed.

  10. A Rapid, Low-Cost Method to Determine Travel Times at Managed Aquifer Recharge Operations Using Noble Gas Tracers

    NASA Astrophysics Data System (ADS)

    Moran, J. E.; Visser, A.; Singleton, M. J.; Esser, B. K.; Halliwell, M.; Hillegonds, D. J.

    2012-12-01

    Managed aquifer recharge is a key component for the sustainable use of surface water and groundwater in the arid western U.S. When recycled water is a recharge water source, subsurface residence time, required for bacteria and virus deactivation, is best verified by application of an extrinsic tracer. Desirable tracer properties include: no real or perceived health risk, inexpensive even for a large volume of tagged water, large dynamic range, efficient introduction, convenient sampling methods, and rapid, low-cost analysis. We have developed and tested a dissolved noble gas tracer technique ideally suited for tracing large water volumes at managed aquifer recharge facilities. In an application of the method at a water district's facilities in the San Francisco Bay area, Xenon was introduced into a 106 m3 pond over a period of 7 days using a 300 m length of gas-permeable silicone tubing. Samples from the pond, near-field shallow monitoring wells, and production wells about 400 m from the recharge pond were analyzed for dissolved Xe by noble gas membrane inlet mass spectrometry (NGMIMS). The NGMIMS uses a syringe pump, gas-permeable membrane inlet, and quadrupole residual gas analyzer for measurement of noble gas concentrations. Samples are collected in VOA vials, and analysis can be carried out in real-time, with a measurement uncertainty of about 5% for Xe. Tracer first appeared in a production well 136 days after starting the tracer introduction at 0.7% (C/C0) of the peak pond xenon concentration. The cost of the tracer is about US650/106 m3 water, and the NGMIMS was assembled with parts totaling approximately US50,000, making application of the tracer method feasible for most managed aquifer recharge projects. This project is part of the California State Water Resources Control Board Groundwater Ambient Monitoring and Assessment (GAMA) Program.

  11. INITIAL ASSESSMENT OF SURFACE PRESSURE CHARACTERISTICS OF TWO ROTARY WING UAV DESIGNS

    NASA Technical Reports Server (NTRS)

    Jones, Henry E.; Wong, Oliver D.; Watkins, A. Neal; Noonan, Kevin W.; Reis, Deane G.; Malovrh, Brendon D.; Ingram, Joanne L.

    2006-01-01

    This paper presents results of an experimental investigation of two rotary-wing UAV designs. The primary goal of the investigation was to provide a set of interactional aerodynamic data for an emerging class of rotorcraft. The present paper provides an overview of the test and an introduction to the test articles, and instrumentation. Sample data in the form of fixed system pressure coefficient response to changes in configuration attitude and flight condition for both rotor off and on conditions are presented. The presence of the rotor is seen to greatly affect the magnitude of the response. Pressure coefficients were measured using both conventional pressure taps and via pressure sensitive paint. Comparisons between the two methods are presented and demonstrate that the pressure sensitive paint is a promising method; however, further work on the technique is required.

  12. Iterative refinement of implicit boundary models for improved geological feature reproduction

    NASA Astrophysics Data System (ADS)

    Martin, Ryan; Boisvert, Jeff B.

    2017-12-01

    Geological domains contain non-stationary features that cannot be described by a single direction of continuity. Non-stationary estimation frameworks generate more realistic curvilinear interpretations of subsurface geometries. A radial basis function (RBF) based implicit modeling framework using domain decomposition is developed that permits introduction of locally varying orientations and magnitudes of anisotropy for boundary models to better account for the local variability of complex geological deposits. The interpolation framework is paired with a method to automatically infer the locally predominant orientations, which results in a rapid and robust iterative non-stationary boundary modeling technique that can refine locally anisotropic geological shapes automatically from the sample data. The method also permits quantification of the volumetric uncertainty associated with the boundary modeling. The methodology is demonstrated on a porphyry dataset and shows improved local geological features.

  13. THE PROCESS OF Leishmania INFECTION - DISEASE AND NEW PERSPECTIVES OF PALEOPARASITOLOGY

    PubMed Central

    NOVO, Shênia Patrícia Corrêa; LELES, Daniela; BIANUCCI, Raffaella; ARAUJO, Adauto

    2016-01-01

    Species of the genus Leishmania (Kinetoplastida, Trypanosomatidae) are causative agents of leishmaniasis, a complex disease with variable clinical spectrum and epidemiological diversity, constituting, in some countries, a serious public health problem. The origin and evolution of leishmaniasis has been under discussion regarding some clinical and parasitological aspects. After the introduction of paleoparasitology, molecular methods and immunodiagnostic techniques have been applied allowing the recovery of parasite remains, as well as the diagnosis of past infections in humans and other hosts. The dating of archaeological samples has allowed the parasitological analysis in time and space. This manuscript presents the state of the art of leishmaniasis and prospects related to paleoparasitology studies and their contribution to the evolutionary and phylogenetic clarification of parasites belonging to the genus Leishmania, and the leishmaniasis caused by them. PMID:27253747

  14. User's manual for two dimensional FDTD version TEA and TMA codes for scattering from frequency-independent dielectic materials

    NASA Technical Reports Server (NTRS)

    Beggs, John H.; Luebbers, Raymond J.; Kunz, Karl S.

    1991-01-01

    The Penn State Finite Difference Time Domain Electromagnetic Scattering Code Versions TEA and TMA are two dimensional numerical electromagnetic scattering codes based upon the Finite Difference Time Domain Technique (FDTD) first proposed by Yee in 1966. The supplied version of the codes are two versions of our current two dimensional FDTD code set. This manual provides a description of the codes and corresponding results for the default scattering problem. The manual is organized into eleven sections: introduction, Version TEA and TMA code capabilities, a brief description of the default scattering geometry, a brief description of each subroutine, a description of the include files (TEACOM.FOR TMACOM.FOR), a section briefly discussing scattering width computations, a section discussing the scattering results, a sample problem set section, a new problem checklist, references and figure titles.

  15. User's manual for two dimensional FDTD version TEA and TMA codes for scattering from frequency-independent dielectric materials

    NASA Technical Reports Server (NTRS)

    Beggs, John H.; Luebbers, Raymond J.; Kunz, Karl S.

    1991-01-01

    The Penn State Finite Difference Time Domain Electromagnetic Scattering Code Versions TEA and TMA are two dimensional electromagnetic scattering codes based on the Finite Difference Time Domain Technique (FDTD) first proposed by Yee in 1966. The supplied version of the codes are two versions of our current FDTD code set. This manual provides a description of the codes and corresponding results for the default scattering problem. The manual is organized into eleven sections: introduction, Version TEA and TMA code capabilities, a brief description of the default scattering geometry, a brief description of each subroutine, a description of the include files (TEACOM.FOR TMACOM.FOR), a section briefly discussing scattering width computations, a section discussing the scattering results, a sample problem setup section, a new problem checklist, references, and figure titles.

  16. Fiber-Optic Chemical Sensors and Fiber-Optic Bio-Sensors

    PubMed Central

    Pospíšilová, Marie; Kuncová, Gabriela; Trögl, Josef

    2015-01-01

    This review summarizes principles and current stage of development of fiber-optic chemical sensors (FOCS) and biosensors (FOBS). Fiber optic sensor (FOS) systems use the ability of optical fibers (OF) to guide the light in the spectral range from ultraviolet (UV) (180 nm) up to middle infrared (IR) (10 µm) and modulation of guided light by the parameters of the surrounding environment of the OF core. The introduction of OF in the sensor systems has brought advantages such as measurement in flammable and explosive environments, immunity to electrical noises, miniaturization, geometrical flexibility, measurement of small sample volumes, remote sensing in inaccessible sites or harsh environments and multi-sensing. The review comprises briefly the theory of OF elaborated for sensors, techniques of fabrications and analytical results reached with fiber-optic chemical and biological sensors. PMID:26437407

  17. User's manual for three dimensional FDTD version C code for scattering from frequency-independent dielectric and magnetic materials

    NASA Technical Reports Server (NTRS)

    Beggs, John H.; Luebbers, Raymond J.; Kunz, Karl S.

    1991-01-01

    The Penn State Finite Difference Time Domain Electromagnetic Scattering Code Version C is a three dimensional numerical electromagnetic scattering code based upon the Finite Difference Time Domain Technique (FDTD). The supplied version of the code is one version of our current three dimensional FDTD code set. This manual provides a description of the code and corresponding results for several scattering problems. The manual is organized into fourteen sections: introduction, description of the FDTD method, operation, resource requirements, Version C code capabilities, a brief description of the default scattering geometry, a brief description of each subroutine, a description of the include file (COMMONC.FOR), a section briefly discussing Radar Cross Section (RCS) computations, a section discussing some scattering results, a sample problem setup section, a new problem checklist, references and figure titles.

  18. User's manual for three dimensional FDTD version D code for scattering from frequency-dependent dielectric and magnetic materials

    NASA Technical Reports Server (NTRS)

    Beggs, John H.; Luebbers, Raymond J.; Kunz, Karl S.

    1991-01-01

    The Penn State Finite Difference Time Domain Electromagnetic Scattering Code Version D is a three dimensional numerical electromagnetic scattering code based upon the Finite Difference Time Domain Technique (FDTD). The supplied version of the code is one version of our current three dimensional FDTD code set. This manual provides a description of the code and corresponding results for several scattering problems. The manual is organized into fourteen sections: introduction, description of the FDTD method, operation, resource requirements, Version D code capabilities, a brief description of the default scattering geometry, a brief description of each subroutine, a description of the include file (COMMOND.FOR), a section briefly discussing Radar Cross Section (RCS) computations, a section discussing some scattering results, a sample problem setup section, a new problem checklist, references and figure titles.

  19. User's manual for three dimensional FDTD version A code for scattering from frequency-independent dielectric materials

    NASA Technical Reports Server (NTRS)

    Beggs, John H.; Luebbers, Raymond J.; Kunz, Karl S.

    1992-01-01

    The Penn State Finite Difference Time Domain (FDTD) Electromagnetic Scattering Code Version A is a three dimensional numerical electromagnetic scattering code based on the Finite Difference Time Domain technique. The supplied version of the code is one version of our current three dimensional FDTD code set. The manual provides a description of the code and the corresponding results for the default scattering problem. The manual is organized into 14 sections: introduction, description of the FDTD method, operation, resource requirements, Version A code capabilities, a brief description of the default scattering geometry, a brief description of each subroutine, a description of the include file (COMMONA.FOR), a section briefly discussing radar cross section (RCS) computations, a section discussing the scattering results, a sample problem setup section, a new problem checklist, references, and figure titles.

  20. User's manual for three dimensional FDTD version B code for scattering from frequency-dependent dielectric materials

    NASA Technical Reports Server (NTRS)

    Beggs, John H.; Luebbers, Raymond J.; Kunz, Karl S.

    1991-01-01

    The Penn State Finite Difference Time Domain Electromagnetic Scattering Code Version B is a three dimensional numerical electromagnetic scattering code based upon the Finite Difference Time Domain Technique (FDTD). The supplied version of the code is one version of our current three dimensional FDTD code set. This manual provides a description of the code and corresponding results for several scattering problems. The manual is organized into fourteen sections: introduction, description of the FDTD method, operation, resource requirements, Version B code capabilities, a brief description of the default scattering geometry, a brief description of each subroutine, a description of the include file (COMMONB.FOR), a section briefly discussing Radar Cross Section (RCS) computations, a section discussing some scattering results, a sample problem setup section, a new problem checklist, references and figure titles.

  1. Study of the oxidized and non- oxidized bitumen modified with additive «Adgezolin» by using electron paramagnetic resonance

    NASA Astrophysics Data System (ADS)

    Mukhamatdinov, I.; Gafurov, M.; Kemalov, A.; Rodionov, A.; Mamin, G.; Fakhretdinov, P.

    2018-05-01

    Cationic surfactant (adhesion additive) «Adgezolin» has been developed. It is shown that introduction of «Adgezolin» into the oxidized bitumen increases the relative amount of asphaltenes and monocyclearomatic hydrocarbons. By means of electron paramagnetic resonance (EPR) it is demonstrated that the introduction of additive «Adgezolin» increases the number of paramagnetic «free» carbon radicals (FR) in the oxidized bitumen and decreases that in the unoxidized species. In both types of bitumen shift from the Lorentzian to Gaussian EPR lineshape of FR is obtained that could be connected with as an increase of the samples homogeneity. It is supposed that while in the oxygenated bitumens introduction of additives leads to the disaggregation of asphaltene-resins compounds, in the unoxidized samples the balance is shifted towards formation of di-radicals.

  2. Using a Smartphone Camera for Nanosatellite Attitude Determination

    NASA Astrophysics Data System (ADS)

    Shimmin, R.

    2014-09-01

    The PhoneSat project at NASA Ames Research Center has repeatedly flown a commercial cellphone in space. As this project continues, additional utility is being extracted from the cell phone hardware to enable more complex missions. The camera in particular shows great potential as an instrument for position and attitude determination, but this requires complex image processing. This paper outlines progress towards that image processing capability. Initial tests on a small collection of sample images have demonstrated the determination of a Moon vector from an image by automatic thresholding and centroiding, allowing the calibration of existing attitude control systems. Work has been undertaken on a further set of sample images towards horizon detection using a variety of techniques including thresholding, edge detection, applying a Hough transform, and circle fitting. Ultimately it is hoped this will allow calculation of an Earth vector for attitude determination and an approximate altitude. A quick discussion of work towards using the camera as a star tracker is then presented, followed by an introduction to further applications of the camera on space missions.

  3. Analytic nuclear forces and molecular properties from full configuration interaction quantum Monte Carlo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, Robert E.; Overy, Catherine; Opalka, Daniel

    Unbiased stochastic sampling of the one- and two-body reduced density matrices is achieved in full configuration interaction quantum Monte Carlo with the introduction of a second, “replica” ensemble of walkers, whose population evolves in imaginary time independently from the first and which entails only modest additional computational overheads. The matrices obtained from this approach are shown to be representative of full configuration-interaction quality and hence provide a realistic opportunity to achieve high-quality results for a range of properties whose operators do not necessarily commute with the Hamiltonian. A density-matrix formulated quasi-variational energy estimator having been already proposed and investigated, themore » present work extends the scope of the theory to take in studies of analytic nuclear forces, molecular dipole moments, and polarisabilities, with extensive comparison to exact results where possible. These new results confirm the suitability of the sampling technique and, where sufficiently large basis sets are available, achieve close agreement with experimental values, expanding the scope of the method to new areas of investigation.« less

  4. Deep Keck u-Band Imaging of the Hubble Ultra Deep Field: A Catalog of z ~ 3 Lyman Break Galaxies

    NASA Astrophysics Data System (ADS)

    Rafelski, Marc; Wolfe, Arthur M.; Cooke, Jeff; Chen, Hsiao-Wen; Armandroff, Taft E.; Wirth, Gregory D.

    2009-10-01

    We present a sample of 407 z ~ 3 Lyman break galaxies (LBGs) to a limiting isophotal u-band magnitude of 27.6 mag in the Hubble Ultra Deep Field. The LBGs are selected using a combination of photometric redshifts and the u-band drop-out technique enabled by the introduction of an extremely deep u-band image obtained with the Keck I telescope and the blue channel of the Low Resolution Imaging Spectrometer. The Keck u-band image, totaling 9 hr of integration time, has a 1σ depth of 30.7 mag arcsec-2, making it one of the most sensitive u-band images ever obtained. The u-band image also substantially improves the accuracy of photometric redshift measurements of ~50% of the z ~ 3 LBGs, significantly reducing the traditional degeneracy of colors between z ~ 3 and z ~ 0.2 galaxies. This sample provides the most sensitive, high-resolution multi-filter imaging of reliably identified z ~ 3 LBGs for morphological studies of galaxy formation and evolution and the star formation efficiency of gas at high redshift.

  5. Visualizing 3D Food Microstructure Using Tomographic Methods: Advantages and Disadvantages.

    PubMed

    Wang, Zi; Herremans, Els; Janssen, Siem; Cantre, Dennis; Verboven, Pieter; Nicolaï, Bart

    2018-03-25

    X-ray micro-computed tomography (micro-CT) provides the unique ability to capture intact internal microstructure data without significant preparation of the sample. The fundamentals of micro-CT technology are briefly described along with a short introduction to basic image processing, quantitative analysis, and derivative computational modeling. The applications and limitations of micro-CT in industries such as meat, dairy, postharvest, and bread/confectionary are discussed to serve as a guideline to the plausibility of utilizing the technique for detecting features of interest. Component volume fractions, their respective size/shape distributions, and connectivity, for example, can be utilized for product development, manufacturing process tuning and/or troubleshooting. In addition to determining structure-function relations, micro-CT can be used for foreign material detection to further ensure product quality and safety. In most usage scenarios, micro-CT in its current form is perfectly adequate for determining microstructure in a wide variety of food products. However, in low-contrast and low-stability samples, emphasis is placed on the shortcomings of the current systems to set realistic expectations for the intended users.

  6. Hydration: certain basic aspects for developing technical and scientific parameters into the nutrition knowledge

    PubMed

    Perales-García, Aránzazu; Estévez-Martínez, Isabel; Urrialde, Rafael

    2016-07-12

    Introduction: Hydration is defined as the water intake coming from food and beverages. Its study has become an area by itself, within the nutrition field. Meaning that in 2010 the European Food Safety Authority (EFSA) approved the water intake recommendations, but the study of this topic implies a rigorous methodology, which represents several issues. Objective: Showing as a glance the main methodological issues in hydration studies. Material and methods: Bibliographic revision of scientific literature. Results: The main methodological issues presented are: sample selection (investigation field and sample design), selection of the method to evaluate hydration status (dilution techniques, bioelectrical impedance, plasmatic and urinary indicators, changes in body composition, water losses and clinic symptoms) selection of the method to evaluate water intake (biomarker, questionnaires, informatics programs, smartphone use, 24-h register, dietary history and food frequency questionnaire), and the main sources of hydration. Conclusions: Hydration status should be understood as a routine model, with daily frequency, according to gender, age, physical activity and environmental conditions. Furthermore, the correct design of the methodology has a special importance in order to take into account all the aspects

  7. Lakes and reservoirs—Guidelines for study design and sampling

    USGS Publications Warehouse

    ,

    2015-09-29

    The “National Field Manual for the Collection of Water-Quality Data” (NFM) is an online report with separately published chapters that provides the protocols and guidelines by which U.S. Geological Survey personnel obtain the data used to assess the quality of the Nation’s surface-water and groundwater resources. Chapter A10 reviews limnological principles, describes the characteristics that distinguish lakes from reservoirs, and provides guidance for developing temporal and spatial sampling strategies and data-collection approaches to be used in lake and reservoir environmental investigations.Within this chapter are references to other chapters of the NFM that provide more detailed guidelines related to specific topics and more detailed protocols for the quality assurance and assessment of the lake and reservoir data. Protocols and procedures to address and document the quality of lake and reservoir investigations are adapted from, or referenced to, the protocols and standard operating procedures contained in related chapters of this NFM.Before 2017, the U.S. Geological Survey (USGS) “National Field Manual for the Collection of Water-Quality Data” (NFM) chapters were released in the USGS Techniques of Water-Resources Investigations series. Effective in 2018, new and revised NFM chapters are being released in the USGS Techniques and Methods series; this series change does not affect the content and format of the NFM. More information is in the general introduction to the NFM (USGS Techniques and Methods, book 9, chapter A0, 2018) at https://doi.org/10.3133/tm9A0. The authoritative current versions of NFM chapters are available in the USGS Publications Warehouse at https://pubs.er.usgs.gov. Comments, questions, and suggestions related to the NFM can be addressed to nfm-owq@usgs.gov.

  8. Friction coefficient of spruce pine on steel -- a note on lubricants

    Treesearch

    Charles W. McMillin; Truett J. Lemoine; Floyd G. Manwiller

    1970-01-01

    Generally, the introduction of water and ethanol increased the friction coefficient for ovendry samples but decreased the coeffecient when the samples were saturated. Octanoic acid decreased the coefficient when samples were wet. In the entire experiment, coefficients ranged from 0.14 to 0.78.

  9. Design and performance of a new continuous-flow sample-introduction system for flame infrared-emission spectrometry: Applications in process analysis, flow injection analysis, and ion-exchange high-performance liquid chromatography.

    PubMed

    Lam, C K; Zhang, Y; Busch, M A; Busch, K W

    1993-06-01

    A new sample introduction system for the analysis of continuously flowing liquid streams by flame infrared-emission (FIRE) spectrometry has been developed. The system uses a specially designed purge cell to strip dissolved CO(2) from solution into a hydrogen gas stream that serves as the fuel for a hydrogen/air flame. Vibrationally excited CO(2) molecules present in the flame are monitored with a simple infrared filter (4.4 mum) photometer. The new system can be used to introduce analytes as a continuous liquid stream (process analysis mode) or on a discrete basis by sample injection (flow injection analysis mode). The key to the success of the method is the new purge-cell design. The small internal volume of the cell minimizes problems associated with purge-cell clean-out and produces sharp, reproducible signals. Spent analytical solution is continuously drained from the cell, making cell disconnection and cleaning between samples unnecessary. Under the conditions employed in this study, samples could be analyzed at a maximum rate of approximately 60/h. The new sample introduction system was successfully tested in both a process analysis- and a flow injection analysis mode for the determination of total inorganic carbon in Waco tap water. For the first time, flame infrared-emission spectrometry was successfully extended to non-volatile organic compounds by using chemical pretreatment with peroxydisulfate in the presence of silver ion to convert the analytes into dissolved carbon dioxide, prior to purging and detection by the FIRE radiometer. A test of the peroxydisulfate/Ag(+) reaction using six organic acids and five sugars indicated that all 11 compounds were oxidized to nearly the same extent. Finally, the new sample introduction system was used in conjunction with a simple filter FIRE radiometer as a detection system in ion-exchange high-performance liquid chromatography. Ion-exchange chromatograms are shown for two aqueous mixtures, one containing six organic acids and the second containing six mono-, di-, and trisaccharides.

  10. Introduction to Special Section on Results of the Lunar Reconnaissance Orbiter Mission

    NASA Technical Reports Server (NTRS)

    Vondrak, Richard R.

    2012-01-01

    Since 2009 the Lunar Reconnaissance Orbiter (LRO) has made comprehensive measurements of the Moon and its environment. The seven LRO instruments use a variety of primarily remote sensing techniques to obtain a unique set of observations. The analyses of the LRO data sets have overturned previous beliefs and deepened our appreciation of the complex nature of our nearest neighbor. This introduction to the special section describes the LRO mission and summarizes some of the science results in the papers that follow.

  11. ISST (Intercontinental Ballistic Missile Silo Superhardening Technology) Structure with SIFCON (Slurry-Infiltrated Fiber Concrete) - HFC-2 Test

    DTIC Science & Technology

    1988-04-01

    Government-related pro- curement, the United States Government incurs no responsibility or any obli -j gation whatsoever. The fact that the Government...Arizona. NIIERI then began a program to deveiop a slurry mix design for use in the structure, as well as construction techniques for placing the SIFCON in...OBJECTIVES 3 II CONSTRUCTION AND FIELDING OPERATIONS 4 INTRODUCTION 4 I DEMONSTRATION PROGRAM 4 Introduct ion 4 Procedure 4 Results 7 $ DESIGN 7 I ntrod uc

  12. IM-CRDS for the analysis of matrix-bound water isotopes: a streamlined (and updated) tool for ecohydrologists to probe small-scale variability in plants Yasuhara, S. (syasuhara@picarro.com)1,Carter, J.A. (jcarter@picarro.com)1, Dennis, K.J. (kdennis@picarro.com)1 1Picarro Inc., 3105 Patrick Henry Drive, Santa Clara, CA 95054

    NASA Astrophysics Data System (ADS)

    Yasuhara, S.

    2013-12-01

    The ability to measure the isotopic composition of matrix-bound water is valuable to many facets of earth and environmental sciences. For example, ecohydrologists use stable isotopes of oxygen and hydrogen in plant and soil water, in combination with measurements of atmospheric water vapor, surface water and precipitation, to estimate budgets of evapotranspiration. Likewise, water isotopes of oceanic water, brines and other waters with high total dissolved solids (TDS, e.g., juices) are relevant to studying large-scale oceanic circulation, small-scale mixing, groundwater contamination, the balance of evaporation to precipitation, and the provenance of food. Conventionally matrix-bound water has been extracted using cryogenic distillation, whereby water is distilled from the material in question (e.g., a leaf sample) by heating under vacuum and collecting the resultant water vapor using liquid nitrogen. The water can then be analyzed for its stable isotopic composition by a variety of methods, including isotope ratio mass spectrometry and laser techniques, such as Cavity Ring-Down Spectroscopy (CRDS). Here we present recent improvements in an alternative, and stream-lined, solution for integrated sample extraction and isotopic measurement using a Picarro Induction Module (IM) coupled to commercially-available CRDS analyzer from Picarro. This technique is also valuable for waters with high TDS, which can have detrimental effects on flash vaporization process, typically used for the introduction of water to Picarro CRDS water isotope analyzers. The IM works by inductively heating a sample held within a metal sample holder in a glass vial flushed with dry air. Tested samples include leaves, stems, twigs, calibration water, juices, and salt water. The heating process evolves water vapor which is then swept through the system at approximately 150 standard cubic centimeters per minute. The evolved water vapor passes through an activated charcoal cartridge for removal of large organics, and then through Picarro's Micro-Combustion Cartridge that acts to oxidize interfering organics to CO2 and H2O. Using an open-split, the IM is interfaced directly with a CRDS system (in this case, an L2130-i) for the measurement of δ18O and δD. Based on replicate measurements of water introduced to the system using glass filter paper, the precision of the system is better than 0.35 and 1.5 ‰ for δ18O and δD, respectively. We will present improvements in system operation that have reduced systematic errors associated with (i) variable backgrounds, and (ii) exchange between the sample and the local atmosphere during sample introduction. In addition, we will present calibration data, and data demonstrating the effectiveness of the Micro-Combustion Cartridge at removing organics, which can result in spectroscopic interference. Finally, we will compare localized leaf water data against integrated whole leaf water data to demonstrate the added value of being able to sample small (approximately 5 mm diameter) areas of a leaf, and compare the results of measuring samples with high TDS on an IM and a Picarro High Precision Vaporizer.

  13. Introduction: Particles and fields

    NASA Astrophysics Data System (ADS)

    Moore, Thomas; Spann, James

    2017-02-01

    A Conference on Measurement Techniques for Solar and Space Physics was held on 20-24 April 2015 in Boulder, Colorado, at the National Center for Atmospheric Research Center Green Campus. The present volume collects together the papers from this conference in the categories of particles and fields. This also includes neutral gas techniques as well as low-energy ionospheric plasmas and their interactions with spacecrafts.

  14. Introduction: Particles and Fields

    NASA Technical Reports Server (NTRS)

    Moore, Thomas E.; Spann, James F.

    2017-01-01

    A Conference on Measurement Techniques for Solar and Space Physics was held on 20-24 April 2015 in Boulder, Colorado, at the National Center for Atmospheric Research Center Green Campus. The present volume collects together the papers from this conference in the categories of particles and fields. This also includes neutral gas techniques as well as low-energy ionospheric plasmas and their interactions with spacecrafts.

  15. Nuclear Technology. Course 32: Nondestructive Examination (NDE) Techniques II. Module 32-6, Operation of Eddy Current Test Equipment.

    ERIC Educational Resources Information Center

    Espy, John; Selleck, Ben

    This sixth in a series of six modules for a course titled Nondestructive Examination (NDE) Techniques II details eddy current examination of steam generator tubing. The module follows a typical format that includes the following sections: (1) introduction, (2) module prerequisites, (3) objectives, (4) notes to instructor/student, (5) subject…

  16. Mapping ecological risks with a portfolio-based technique: incorporating uncertainty and decision-making preferences

    Treesearch

    Denys Yemshanov; Frank H. Koch; Mark Ducey; Klaus Koehler

    2013-01-01

    Geographic mapping of risks is a useful analytical step in ecological risk assessments and in particular, in analyses aimed to estimate risks associated with introductions of invasive organisms. In this paper, we approach invasive species risk mapping as a portfolio allocation problem and apply techniques from decision theory to build an invasion risk map that combines...

  17. Strains on the nano- and microscale in nickel-titanium: An advanced TEM study

    NASA Astrophysics Data System (ADS)

    Tirry, Wim

    2007-12-01

    A general introduction to shape memory behavior and the martensitic transformation is given in chapter 1, with speck information concerning the NiTi material. The technique used to study the material is transmission electron microscopy (TEM) of which the basics are explained in chapter 2 as well as information concerning the NiTi material. The main goal was to apply more advanced TEM techniques in order to measure some aspects in a quantitative way rather than qualitative, which is mostly the case in conventional TEM. (1) Quantitative electron diffraction was used to refine the structure of Ni4Ti3 precipitates, this was done by using the MSLS method in combination with density functional theory (DFT) calculations. (2) These Ni4Ti3 precipitates are (semi-)coherent which results in a strain field in the matrix close to the precipitate. High resolution TEM (HRTEM) in combination with image processing techniques was used to measure these strain fields. The obtained results are compared to the Eshelby model for elliptical inclusions, and major difference is an underestimation of the strain magnitude by the model. One of the algorithms used to extract strain information from HRTEM images is the geometric phase method. (3) The Ni4Ti3-Ni4Ti3 and Ni4Ti3-precipitate interface was investigated with HRTEM showing that the Ni4Ti3-precipitate interface might be diffuse over a range of 3nm. (4) In-situ straining experiments were performed on single crystalline and superelastic polycrystalline NiTi samples. It seems that the strain induced martensite planes in the polycrystalline sample show no sign of twinning. This is in contradiction to what is expected and is discussed in the view of the crystallographic theory of martensite, in addition a first model explaining this behavior is proposed. In this dissertation the main attention is divided over the material aspects of NiTi and on how to apply these more advanced TEM techniques.

  18. Reducing salt in bread: a quasi-experimental feasibility study in a bakery in Lima, Peru.

    PubMed

    Saavedra-Garcia, Lorena; Sosa-Zevallos, Vanessa; Diez-Canseco, Francisco; Miranda, J Jaime; Bernabe-Ortiz, Antonio

    2016-04-01

    To explore salt content in bread and to evaluate the feasibility of reducing salt contained in 'pan francés' bread. The study had two phases. Phase 1, an exploratory phase, involved the estimation of salt contained in bread as well as a triangle taste test to establish the amount of salt to be reduced in 'pan francés' bread without detection by consumers. In Phase 2, a quasi-experimental, pre-post intervention study assessed the effects of the introduction of low-salt bread on bakery sales. A municipal bakery in Miraflores, Lima, Peru. Sixty-five clients of the bakery in Phase 1 of the study; sales to usual costumers in Phase 2. On average, there was 1·25 g of salt per 100 g of bread. Sixty-five consumers were enrolled in the triangle taste test: fifty-four (83·1 %) females, mean age 58·9 (sd 13·7) years. Based on taste, bread samples prepared with salt reductions of 10 % (P=0·82) and 20 % (P=0·37) were not discernible from regular bread. The introduction of bread with 20 % of salt reduction, which contained 1 g of salt per 100 g of bread, did not change sales of 'pan francés' (P=0·70) or other types of bread (P=0·36). Results were consistent when using different statistical techniques. The introduction of bread with a 20 % reduction in salt is feasible without affecting taste or bakery sales. Results suggest that these interventions are easily implementable, with the potential to contribute to larger sodium reduction strategies impacting the population's cardiovascular health.

  19. The foot as a barrier in patients with early rheumatoid arthritis - an interview study among Swedish women and men.

    PubMed

    Björk, Mathilda; Thyberg, Ingrid; Valtersson, Eva; Östlund, Gunnel; Stenström, Birgitta; Sverker, Annette

    2017-12-01

    Foot impairments are related to reduced mobility and participation restrictions in daily activities in patients with established rheumatoid arthritis (RA). The new biological medications are effective and reduce disease activity, but not disability to the same extent. Foot impairments are assumed to be related to participation restrictions also in patients with early RA, diagnosed after the introduction of biological medications. The knowledge of foot impairments needs to be more explored after the introduction of biological disease-modifying drugs (bDMARDs). The aim of this study was to explore the patients' perspective of foot impairments related to early RA. The sample included 59 patients (20-63 years) who were interviewed about participation dilemmas in daily life using the Critical Incident Technique. The interviews were audio-recorded and transcribed. Data related to foot impairments were extracted and analyzed thematically. A research partner validated the analysis. The study was approved by the Regional Ethics Committee. Patients with early RA described a variety of participation restrictions related to foot impairments: 1) foot hindrances in domestic life, 2) foot impairments influencing work, 3) leisure activities restricted by one's feet 4) struggling to be mobile 5) foot impairments as an early sign of rheumatic disease. There is a need to focus on foot impairments related to early RA, and for health care professionals to understand these signs. A suggestion for future research is to conduct a longitudinal follow-up of foot impairment related to medication, disease activity and disability in patients diagnosed after the introduction of bDMARDs. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  20. Respondent-Driven Sampling with Hard-to-Reach Emerging Adults: An Introduction and Case Study with Rural African Americans

    ERIC Educational Resources Information Center

    Kogan, Steven M.; Wejnert, Cyprian; Chen, Yi-fu; Brody, Gene H.; Slater, LaTrina M.

    2011-01-01

    Obtaining representative samples from populations of emerging adults who do not attend college is challenging for researchers. This article introduces respondent-driven sampling (RDS), a method for obtaining representative samples of hard-to-reach but socially interconnected populations. RDS combines a prescribed method for chain referral with a…

  1. Impact of Oxidant Residuals on Ground Water Samples at ISCO Sites: Recommended Guidelines for Sample Preservation

    EPA Science Inventory

    In-situ chemical oxidation (ISCO) involves the introduction of a chemical oxidant into the subsurface for the purpose of transforming ground water contaminants into less toxic or harmless byproducts. Due to oxidant persistence, ground water samples collected at hazardous waste si...

  2. Sponge and skin excision sampling for recovery of Salmonella and Campylobacter from defeathered broiler carcasses

    USDA-ARS?s Scientific Manuscript database

    Introduction: Salmonella and Campylobacter contamination of broiler carcass skin increases during feather removal. There are several methods for sampling carcasses including sponging or swabbing of skin surface and skin excision. It is unclear whether sponge sampling is adequate to remove bacteri...

  3. Sponge and skin excision sampling for recovery of Salmonella and Campylobacter from defeathered broiler carcasses

    USDA-ARS?s Scientific Manuscript database

    Introduction: Salmonella and Campylobacter contamination of broiler carcass skin increases during feather removal. There are several methods for sampling carcasses including sponging or swabbing of skin surface and skin excision. It is unclear whether sponge sampling is adequate to remove bacteria f...

  4. Wildfire Prevention Strategies.

    ERIC Educational Resources Information Center

    National Wildlife Coordinating Group, Boise, ID.

    This document provides information and guidance on wildfire prevention strategies. Chapters include: (1) "Introduction"; (2) "How to Use this Guide"; (3) "Fire Cause Classification"; (4) "Relative Effectiveness"; (5) "Degree of Difficulty"; (6) "Intervention Techniques"; (7)…

  5. Analysis of trimethoprim, lincomycin, sulfadoxin and tylosin in swine manure using laser diode thermal desorption-atmospheric pressure chemical ionization-tandem mass spectrometry.

    PubMed

    Solliec, Morgan; Massé, Daniel; Sauvé, Sébastien

    2014-10-01

    A new extraction method coupled to a high throughput sample analysis technique was developed for the determination of four veterinary antibiotics. The analytes belong to different groups of antibiotics such as chemotherapeutics, sulfonamides, lincosamides and macrolides. Trimethoprim (TMP), sulfadoxin (SFX), lincomycin (LCM) and tylosin (TYL) were extracted from lyophilized manure using a sonication extraction. McIlvaine buffer and methanol (MeOH) were used as extraction buffers, followed by cation-exchange solid phase extraction (SPE) for clean-up. Analysis was performed by laser diode thermal desorption-atmospheric pressure chemical-ionization (LDTD-APCI) tandem mass spectrometry (MS/MS) with selected reaction monitoring (SRM) detection. The LDTD is a high throughput sample introduction method that reduces total analysis time to less than 15s per sample, compared to minutes when using traditional liquid chromatography (LC). Various SPE parameters were optimized after sample extraction: the stationary phase, the extraction solvent composition, the quantity of sample extracted and sample pH. LDTD parameters were also optimized: solvent deposition, carrier gas, laser power and corona discharge. The method limit of detection (MLD) ranged from 2.5 to 8.3 µg kg(-1) while the method limit of quantification (MLQ) ranged from 8.3 to 28µgkg(-1). Calibration curves in the manure matrix showed good linearity (R(2)≥ 0.996) for all analytes and the interday and intraday coefficients of variation were below 14%. Recoveries of analytes from manure ranged from 53% to 69%. The method was successfully applied to real manure samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. NEOCHIM: An electrochemical method for environmental application

    USGS Publications Warehouse

    Leinz, R.W.; Hoover, D.B.; Meier, A.L.

    1999-01-01

    Ion migration and electroosmosis are the principal processes underlying electrokinetic remediation of hazardous wastes from soils. These processes are a response of charged species to an applied electrical current and they are accompanied by electrolysis of water at the electrodes through which the current is applied. Electrolysis results in the formation of OH- at the cathode and H+ at the anode. The current drives the OH- and H+ thus formed from the electrodes, through the soil and to the electrode of opposite charge. Introduction of OH- and H+ into the soil being treated modifies soil chemistry and can interfere with either the collection or immobilization of hazardous waste ions. The introduction of either OH- or H+ to the soil can be problematic to electrokinetic remediation but the problem caused by OH- has been the focus of most researchers. The problem has been addressed by flushing the OH- from the soil near the cathode or treating the soil with buffers. These treatments would apply as well to soils affected by H+. With the NEOCHIM technology, developed by the U.S. Geological Survey (USGS) for use as a sampling technique in exploration for buried ore deposits, OH- and H+ are retained in the inner compartment of two-compartment electrodes and are thus prevented from reaching the soil. This enables the extraction of cations and anions, including anionic forms of toxic metals such as HAsO42-. One of the principal attributes of NEOCHIM is the large volume of soil from which ions can be extracted. It is mathematically demonstrable that NEOCHIM extraction volumes can be orders of magnitude greater than volumes typically sampled in more conventional geochemical exploration methods or for environmental sampling. The technology may also be used to introduce selected ions into the soil that affect the solubility of ceratin ions present in the soil. Although field tests for mineral exploration have shown NEOCHIM extraction efficiencies of about 25-35%, laboratory experiments suggest that significantly higher efficiencies are possible. The attributes of NEOCHIM combined with relatively low cost of electrical power, indicate that the technology may be useful for remediation and monitoring of hazardous waste sites. Of particular importance is that NEOCHIM extractions affect only dissolved and electrically charged species, hence those prone to move in groundwater.The U.S. Geological Survey (USGS) has developed a technology called NEOCHIM for use as a sampling technique in exploration for buried deposits. With this technology, OH- and H+ are retained in the inner compartment of two-compartment electrodes and are thus prevented from reaching the soil. This enables the extraction of cations and anions. Laboratory experiments suggest extraction efficiencies higher than 25-35%.

  7. Development of a Noninterference Technique for Measurement of Turbine Engine Compressor Blade Stress

    DTIC Science & Technology

    1980-06-01

    TECHNIQUE FOR MEASUREMENT OF TURBINE ENGINE COMPRESSOR BLADE STRESS 7 A U T H O R ( s ) P . E. M c C a r t y a n d J . W. Thompson , J r...e a e a ~ and tdentJ~ by b|ock numbe~ A noninterference technique for measuring stress in compressor blades of turbine engines is being developed...43 4 AEDC-TR-79-78 1.0 INTRODUCTION 1.1 BACKGROUND Compressor rotor blades in turbojet engines are subjected to

  8. Immunohistochemistry: forging the links between immunology and pathology.

    PubMed

    Haines, Deborah M; West, Keith H

    2005-10-18

    The technique of immunohistochemical staining allows the visualization of epitopes in situ in histological tissue sections. A series of innovations in the methods and reagents and the introduction of mechanization have enhanced the ease and technical reliability of this technique resulting in widespread application in veterinary diagnostics and research. This brief overview will highlight some of the applications for immunohistochemical staining with an emphasis on the use of the technique in diagnostic veterinary medicine, particularly for the detection of infectious disease agents.

  9. Laser Spinning: A New Technique for Nanofiber Production

    NASA Astrophysics Data System (ADS)

    Penide, J.; Quintero, F.; del Val, J.; Comesaña, R.; Lusquiños, F.; Riveiro, A.; Pou, J.

    Laser Spinning is a new technique to produce ultralongnanofibers with tailored chemical compositions. In this method, a high power laser is employed to melt a small volume of the precursor material at high temperatures. At the same time, a supersonic gas jet is injected on this molten volume producing its rapid cooling and elongation by viscous friction with the high speed gas flow, hence forming the amorphous nanofibers. This paper collects the main results obtained since the introduction of this technique in 2007.

  10. Confidence level in venipuncture and knowledge on causes of in vitro hemolysis among healthcare professionals

    PubMed Central

    Milutinović, Dragana; Andrijević, Ilija; Ličina, Milijana; Andrijević, Ljiljana

    2015-01-01

    Introduction This study aimed to assess confidence level of healthcare professionals in venipuncture and their knowledge on the possible causes of in vitro hemolysis. Materials and methods A sample of 94 healthcare professionals (nurses and laboratory technicians) participated in this survey study. A four-section questionnaire was used as a research instrument comprising general information for research participants, knowledge on possible causes of in vitro hemolysis due to type of material used and venipuncture technique and specimen handling, as well as assessment of healthcare professionals’ confidence level in their own ability to perform first and last venipuncture. Results The average score on the knowledge test was higher in nurses’ than in laboratory technicians (8.11 ± 1.7, and 7.4 ± 1.5, respectively). The difference in average scores was statistically significant (P = 0.035) and Cohen’s d in the range of 0.4 indicates that there is a moderate difference on the knowledge test among the health care workers. Only 11/94 of healthcare professionals recognized that blood sample collection from cannula and evacuated tube is method which contributes most to the occurrence of in vitro hemolysis, whereas most risk factors affecting occurrence of in vitro hemolysis during venipuncture were recognized. There were no significant differences in mean score on the knowledge test in relation to the confidence level in venipuncture (P = 0.551). Conclusion Confidence level at last venipuncture among both profiles of healthcare staff was very high, but they showed insufficient knowledge about possible factors affecting hemolysis due to materials used in venipuncture compared with factors due to venipuncture technique and handling of blood sample. PMID:26527124

  11. The analysis of ALK gene rearrangement by fluorescence in situ hybridization in non-small cell lung cancer patients

    PubMed Central

    Krawczyk, Paweł Adam; Ramlau, Rodryg Adam; Szumiło, Justyna; Kozielski, Jerzy; Kalinka-Warzocha, Ewa; Bryl, Maciej; Knopik-Dąbrowicz, Alina; Spychalski, Łukasz; Szczęsna, Aleksandra; Rydzik, Ewelina; Milanowski, Janusz

    2013-01-01

    Introduction ALK gene rearrangement is observed in a small subset (3–7%) of non-small cell lung cancer (NSCLC) patients. The efficacy of crizotinib was shown in lung cancer patients harbouring ALK rearrangement. Nowadays, the analysis of ALK gene rearrangement is added to molecular examination of predictive factors. Aim of the study The frequency of ALK gene rearrangement as well as the type of its irregularity was analysed by fluorescence in situ hybridisation (FISH) in tissue samples from NSCLC patients. Material and methods The ALK gene rearrangement was analysed in 71 samples including 53 histological and 18 cytological samples. The analysis could be performed in 56 cases (78.87%), significantly more frequently in histological than in cytological materials. The encountered problem with ALK rearrangement diagnosis resulted from the scarcity of tumour cells in cytological samples, high background fluorescence noises and fragmentation of cell nuclei. Results The normal ALK copy number without gene rearrangement was observed in 26 (36.62%) patients ALK gene polysomy without gene rearrangement was observed in 25 (35.21%) samples while in 3 (4.23%) samples ALK gene amplification was found. ALK gene rearrangement was observed in 2 (2.82%) samples from males, while in the first case the rearrangement coexisted with ALK amplification. In the second case, signet-ring tumour cells were found during histopathological examination and this patient was successfully treated with crizotinib with partial remission lasting 16 months. Conclusions FISH is a useful technique for ALK gene rearrangement analysis which allows us to specify the type of gene irregularities. ALK gene examination could be performed in histological as well as cytological (cellblocks) samples, but obtaining a reliable result in cytological samples depends on the cellularity of examined materials. PMID:24592134

  12. First Detection of Antibodies Against African Swine Fever Virus in Faeces Samples.

    PubMed

    Nieto-Pelegrín, E; Rivera-Arroyo, B; Sánchez-Vizcaíno, J M

    2015-12-01

    African swine fever (ASF) is a viral, highly lethal haemorrhagic disease of swine with no available vaccine or effective treatment. Introduction of ASF into a country triggers immediate restriction measures that cause significant economic losses and threatens spread to neighbouring countries. Wild boar populations have been recently assigned an essential role in the spread of African swine fever virus (ASFV) to European countries. Therefore, effective surveillance and monitoring of wild boar populations is required, but sampling wild boar is logistically challenging and expensive. This study assessed the feasibility of detecting antibodies against ASFV in faeces for later implementation in surveillance and control programmes. Two groups of pigs were experimentally infected with an attenuated ASFV isolate Ken05, and blood, oral fluid and faecal samples were tested for the presence of viral DNA using quantitative real-time polymerase chain reaction (qPCR) to monitor infection progress. Faecal samples were analysed using two indirect enzyme-linked immunosorbent assays (ELISAs) based on semipurified viral protein (vp) 72 or purified recombinant vp30 expressed in mammalian cells. Faecal samples from 9 of 10 pigs with non-haemorrhagic diarrhoea tested positive for antibodies against ASFV using the two ELISA tests that showed a positive correlation. The serum sample results from the two indirect ELISAs were compared against results from the reference ELISA technique and the immunoperoxidase test. Our findings indicate the feasibility of faecal sampling for detecting anti-ASFV antibodies, which may provide a practical non-invasive alternative for sampling wild boar populations. In conclusion, the application of these ELISA tests to faecal field samples could be particularly useful to screen for the presence of ASF in field conditions. © 2015 Blackwell Verlag GmbH.

  13. Social and Cognitive Effects of the Introduction of Television on Rural Alaskan Native Children. Final Report.

    ERIC Educational Resources Information Center

    Forbes, Norma; And Others

    A 5-year study of the social and cognitive effects of the introduction of commercial and educational television on rural Alaskan children utilized a variety of social and cognitive measures given to both longitudinal and cross-sectional samples of grade-school children: in 1977, when no participating village received television; in 1979, when half…

  14. A microfluidic system with integrated molecular imprinting polymer films for surface plasmon resonance detection

    NASA Astrophysics Data System (ADS)

    Huang, Shih-Chiang; Lee, Gwo-Bin; Chien, Fan-Ching; Chen, Shean-Jen; Chen, Wen-Janq; Yang, Ming-Chang

    2006-07-01

    This paper presents a novel microfluidic system with integrated molecular imprinting polymer (MIP) films designed for surface plasmon resonance (SPR) biosensing of multiple nanoscale biomolecules. The innovative microfluidic chip uses pneumatic microvalves and micropumps to transport a precise amount of the biosample through multiple microchannels to sensing regions containing the locally spin-coated MIP films. The signals of SPR biosensing are basically proportional to the number of molecules adsorbed on the MIP films. Hence, a precise control of flow rates inside microchannels is important to determine the adsorption amount of the molecules in the SPR/MIP chips. The integration of micropumps and microvalves can automate the sample introduction process and precisely control the amount of the sample injection to the microfluidic system. The proposed biochip enables the label-free biosensing of biomolecules in an automatic format, and provides a highly sensitive, highly specific and high-throughput detection performance. Three samples, i.e. progesterone, cholesterol and testosterone, are successfully detected using the developed system. The experimental results show that the proposed SPR/MIP microfluidic chip provides a comparable sensitivity to that of large-scale SPR techniques, but with reduced sample consumption and an automatic format. As such, the developed biochip has significant potential for a wide variety of nanoscale biosensing applications. The preliminary results of the current paper were presented at Transducers 2005, Seoul, Korea, 5-9 June 2005.

  15. Water: A Recycling Success Story.

    ERIC Educational Resources Information Center

    Swinehart, Rebecca, Ed.

    1995-01-01

    This activity involves elementary students in simulating water purification techniques by finding ways to clear up soapy water. An introduction discusses water use and conservation. Materials needed and step-by-step procedure are provided. (LZ)

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Diaz-Cruz, J. Lorenzo

    The goal of these lectures is to present a practical introduction to the subject of supersymmetry (SUSY). We shall focus on the basic techniques needed to write down supersymmetric Lagrangians in four and higher dimensions, namely superspace, superfields and their actions.

  17. Introduction to Information Visualization (InfoVis) Techniques for Model-Based Systems Engineering

    NASA Technical Reports Server (NTRS)

    Sindiy, Oleg; Litomisky, Krystof; Davidoff, Scott; Dekens, Frank

    2013-01-01

    This paper presents insights that conform to numerous system modeling languages/representation standards. The insights are drawn from best practices of Information Visualization as applied to aerospace-based applications.

  18. Monitoring hydrilla using two RAPD procedures and the nonindigenous aquatic species database

    USGS Publications Warehouse

    Madeira, Paul T.; Jacono, C.C.; Van, Thai K.

    2000-01-01

    Hydrilla (Hydrilla verticillata (L.f.) Royle), an invasive aquatic weed, continues to spread to new regions in the United States. Two biotypes, one a female dioecious and the other monoecious have been identified. Management of the spread of hydrilla requires understanding the mechanisms of introduction and transport, an ability to map and make available information on distribution, and tools to distinguish the known U.S. biotypes as well as potential new introductions. Review of the literature and discussions with aquatic scientists and resource managers point to the aquarium and water garden plant trades as the primary past mechanism for the regional dispersal of hydrilla while local dispersal is primarily carried out by other mechanisms such as boat traffic, intentional introductions, and waterfowl. The Nonindigenous Aquatic Species (NAS) database is presented as a tool for assembling, geo-referencing, and making available information on the distribution of hydrilla. A map of the current range of dioecious and monoecious hydrilla by drainage is presented. Four hydrilla samples, taken from three discrete, non-contiguous regions (Pennsylvania, Connecticut, and Washington State) were examined using two RAPD assays. The first, generated using primer Operon G17, and capable of distinguishing the dioecious and monoecious U.S. biotypes, indicated all four samples were of the monoecious biotype. Results of the second assay using the Stoffel fragment and 5 primers, produced 111 markers, indicated that these samples do not represent new foreign introductions. The differences in the monoecious and dioecious growth habits and management are discussed.

  19. Determination of As, Se, and Hg in fuel samples by in-chamber chemical vapor generation ICP OES using a Flow Blurring® multinebulizer.

    PubMed

    García, Miriam; Aguirre, Miguel Ángel; Canals, Antonio

    2017-09-01

    In this work, a new and simple analytical methodology based on in-chamber chemical vapor generation has been developed for the spectrochemical analysis of commercial fuel samples. A multiple nebulizer with three nebulization units has been employed for this purpose: One unit was used for sample introduction, while the other two were used for the necessary reagent introduction. In this way, the aerosols were mixed inside the spray chamber. Through this method, analyte transport and, therefore, sensitivity are improved in inductively coupled plasma-optical emission spectrometry. The factors (i.e., variables), influencing chemical vapor generation, have been optimized using a multivariate approach. Under optimum chemical vapor generation conditions ([NaBH 4 ] = 1.39%, [HCl] = 2.97 M, total liquid flow = 936 μL min -1 ), the proposed sample introduction system allowed the determination of arsenic, selenium, and mercury up to 5 μg g -1 with a limit of detection of 25, 140, and 13 μg kg -1 , respectively. Analyzing spiked commercial fuel samples, recovery values obtained were between 96 and 113%, and expanded uncertainty values ranged from 4 to 16%. The most striking practical conclusion of this investigation is that no carbon deposit appears on the plasma torch after extended periods of working. Graphical abstract A new and simple analytical methodology based on in-chamber chemical vapor generation has been developed for the spectrochemical analysis of commercial fuel samples in ICP OES.

  20. Using a business model approach and marketing techniques for recruitment to clinical trials

    PubMed Central

    2011-01-01

    Randomised controlled trials (RCTs) are generally regarded as the gold standard for evaluating health care interventions. The level of uncertainty around a trial's estimate of effect is, however, frequently linked to how successful the trial has been in recruiting and retaining participants. As recruitment is often slower or more difficult than expected, with many trials failing to reach their target sample size within the timescale and funding originally envisaged, the results are often less reliable than they could have been. The high number of trials that require an extension to the recruitment period in order to reach the required sample size potentially delays the introduction of more effective therapies into routine clinical practice. Moreover, it may result in less research being undertaken as resources are redirected to extending existing trials rather than funding additional studies. Poor recruitment to publicly-funded RCTs has been much debated but there remains remarkably little clear evidence as to why many trials fail to recruit well, which recruitment methods work, in which populations and settings and for what type of intervention. One proposed solution to improving recruitment and retention is to adopt methodology from the business world to inform and structure trial management techniques. We review what is known about interventions to improve recruitment to trials. We describe a proposed business approach to trials and discuss the implementation of using a business model, using insights gained from three case studies. PMID:21396088

  1. Development of novel separation techniques for biological samples in capillary electrophoresis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, Huan -Tsung

    1994-07-27

    This dissertation includes three different topics: general introduction of capillary electrophoresis (CE); gradient in CE and CE in biological separations; and capillary gel electrophoresis (CGE) for DNA separation. Factors such as temperature, viscosity, pH, and the surface of capillary walls affecting the separation performance are demonstrated. A pH gradient between 3.0 and 5.2 is useful to improve the resolution among eight different organic acids. A flow gradient due to the change in the concentration of surfactant, which is able to coat to the capillary wall to change the flow rate and its direction, is also shown as a good waymore » to improve the resolution for organic compounds. A temperature gradient caused by joule heat is shown by voltage programming to enhance the resolution and shorten the separation time for several phenolic compounds. The author also shows that self-regulating dynamic control of electroosmotic flow in CE by simply running separation in different concentrations of surfactant has less matrix effect on the separation performance. One of the most important demonstrations in this dissertation is that the author proposes on-column reaction which gives several advantages including the use of a small amount of sample, low risk of contamination, and time saving and kinetic features. The author uses this idea with laser induced fluorescence (LIF) as a detection mode to detect an on-column digestion of sub-ng of protein. This technique also is applied to single cell analysis in the group.« less

  2. Using a business model approach and marketing techniques for recruitment to clinical trials.

    PubMed

    McDonald, Alison M; Treweek, Shaun; Shakur, Haleema; Free, Caroline; Knight, Rosemary; Speed, Chris; Campbell, Marion K

    2011-03-11

    Randomised controlled trials (RCTs) are generally regarded as the gold standard for evaluating health care interventions. The level of uncertainty around a trial's estimate of effect is, however, frequently linked to how successful the trial has been in recruiting and retaining participants. As recruitment is often slower or more difficult than expected, with many trials failing to reach their target sample size within the timescale and funding originally envisaged, the results are often less reliable than they could have been. The high number of trials that require an extension to the recruitment period in order to reach the required sample size potentially delays the introduction of more effective therapies into routine clinical practice. Moreover, it may result in less research being undertaken as resources are redirected to extending existing trials rather than funding additional studies.Poor recruitment to publicly-funded RCTs has been much debated but there remains remarkably little clear evidence as to why many trials fail to recruit well, which recruitment methods work, in which populations and settings and for what type of intervention. One proposed solution to improving recruitment and retention is to adopt methodology from the business world to inform and structure trial management techniques.We review what is known about interventions to improve recruitment to trials. We describe a proposed business approach to trials and discuss the implementation of using a business model, using insights gained from three case studies.

  3. Role of veterinarians in modern food hygiene

    PubMed Central

    Matyáš, Z.

    1978-01-01

    Veterinary services and veterinary education and training must keep pace with the constantly changing patterns of agriculture and food processing. Changes in methods of animal production are associated with many problems of food processing and food quality. Veterinary supervision of the animal feed industry and of meat and distribution is essential. Quality testing of meat, milk, and eggs requires the introduction of suitable routine sampling systems, laboratory procedures, and complex evaluation procedures. Food hygiene problems have changed in recent years not only as a result of new methods of animal production, but also because of changes in food processing technology and in the presentation of food to the consumer, increased environmental pollution, increased international trade, and increased tourist travel. Food hygienists must adopt an active and progressive policy and change the scope of food control from a purely negative measure into a positive force working towards improved food quality and the avoidance of losses during production. A modern food hygiene programme should cover all stages of production, processing, and distribution of food and also other ingredients, additives and the water used for production and processing. Veterinarians should also be involved in the registration and licensing of enterprises and this should take into account the premises, the procedures to be used, new techniques in animal husbandry, machines and equipment, etc. In order to facilitate the microbiological analysis of foodstuffs, new mechanized or automated laboratory methods are required, and consideration must be given to adequate sampling techniques. PMID:310716

  4. Stability of polymorphic forms of ranitidine hydrochloride.

    PubMed

    Wu, V; Rades, T; Saville, D J

    2000-07-01

    Ranitidine-HCl can exist in two different polymorphic forms: form I (m.p. 134-140 degrees C) and form II (m.p. 140-144 degrees C). In the present study the stability of form I of ranitidine-HCl to a selection of powder pretreatments, to reflect conditions which might occur in manufacturing procedures, and also to a limited range of storage conditions was investigated. The original samples of form I and form II used were characterised by X-ray powder diffraction (XRPD), hot stage microscopy (HSM) and differential scanning calorimetry (DSC). A quantitative XRPD method for determining the fraction of form II in the presence of form I was used. XRPD data were analysed using regression techniques and artificial neural networks (ANN). The quantitative XRPD technique was then used to monitor the relative proportion of form II in each treated sample. Pretreatments of form I included (i) mixing with form II or with common excipients (ii) compression and grinding (iii) contact with solvents (followed by drying) before storage. Storage conditions involved three temperatures (20 degrees C, 30 degrees C, 42 degrees C) and three relative humidities (45% RH; 55% RH; 75% RH). Samples were stored for a period of 6 months. A limited factorial design was used. No increase in the form II:form I ratio was observed in the following pretreatment processes: introduction of form II nuclei into form I; introduction of excipients to form I; compression of form I powder at 5 and 15 tons; normal mixing and grinding processes; addition of isopropanol (IPA) or water/IPA mix followed by drying. In the pretreatment process where water was added to form I powder (with most or all of the powder dissolving), drying of the liquefied mass led to a mix of form I and form II. On storage at room temperature (20-30 degrees C), low relative humidity (45-55% RH), and in an air-tight container there was no increase in the form II:form I ratio. Storage of form I/form II mixes, particularly at high humidity, resulted in a preferential loss of form II (compared to form I). Loss was greater at 30 degrees C/75% RH than at 20 degrees C/75% RH. Form II was also preferentially lost under low humidity conditions created by a saturated solution of potassium carbonate (45% RH) at the elevated temperature of 42 degrees C. This environment was shown to be acidic.

  5. From fresh heterologous oocyte donation to autologous oocyte banking

    PubMed Central

    Stoop, D.

    2012-01-01

    Introduction: Today, oocyte donation has become well established, giving rise to thousands of children born worldwide annually. The introduction of oocyte cryopreservation through vitrification allows the introduction of egg banking, improving the efficiency and comfort of oocyte donation. Moreover, the vitrification technique can now enable autologous donation of oocytes to prevent future infertility. Methods: We evaluated fresh heterologous oocyte donation in terms of obstetrical and perinatal outcome as well as of the reproductive outcome of past donors. We then evaluated the efficiency of a closed vitrification device and its clinical applications within ART. Thirdly, we evaluated the opinion of women with regard to preventive egg freezing and the efficiency of a human oocyte in relation to age. Results: Oocyte donation is associated with an increased risk of first trimester bleeding and pregnancy induced hypertension. Donating oocytes does not seem to increase the likelihood for a later need of fertility treatment. The chance of an oocyte to result in live birth (utilization rate) in women <37 years old remains constant with a mean of 4.47%. A significant proportion of young women would consider safeguarding their reproductive potential through egg freezing or are at least open to the idea. Discussion and Conclusion: The introduction of efficient oocyte cryopreservation has revolutionized oocyte donation through the establishment of eggbank donation. The technique also enables women to perform autologous donation after preventive oocyte storage in order to circumvent their biological clock. PMID:24753920

  6. Efficient dynamic graph construction for inductive semi-supervised learning.

    PubMed

    Dornaika, F; Dahbi, R; Bosaghzadeh, A; Ruichek, Y

    2017-10-01

    Most of graph construction techniques assume a transductive setting in which the whole data collection is available at construction time. Addressing graph construction for inductive setting, in which data are coming sequentially, has received much less attention. For inductive settings, constructing the graph from scratch can be very time consuming. This paper introduces a generic framework that is able to make any graph construction method incremental. This framework yields an efficient and dynamic graph construction method that adds new samples (labeled or unlabeled) to a previously constructed graph. As a case study, we use the recently proposed Two Phase Weighted Regularized Least Square (TPWRLS) graph construction method. The paper has two main contributions. First, we use the TPWRLS coding scheme to represent new sample(s) with respect to an existing database. The representative coefficients are then used to update the graph affinity matrix. The proposed method not only appends the new samples to the graph but also updates the whole graph structure by discovering which nodes are affected by the introduction of new samples and by updating their edge weights. The second contribution of the article is the application of the proposed framework to the problem of graph-based label propagation using multiple observations for vision-based recognition tasks. Experiments on several image databases show that, without any significant loss in the accuracy of the final classification, the proposed dynamic graph construction is more efficient than the batch graph construction. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. A rapid and reliable method for Pb isotopic analysis of peat and lichens by laser ablation-quadrupole-inductively coupled plasma-mass spectrometry for biomonitoring and sample screening.

    PubMed

    Kylander, M E; Weiss, D J; Jeffries, T E; Kober, B; Dolgopolova, A; Garcia-Sanchez, R; Coles, B J

    2007-01-16

    An analytical protocol for rapid and reliable laser ablation-quadrupole (LA-Q)- and multi-collector (MC-) inductively coupled plasma-mass spectrometry (ICP-MS) analysis of Pb isotope ratios ((207)Pb/(206)Pb and (208)Pb/(206)Pb) in peats and lichens is developed. This technique is applicable to source tracing atmospheric Pb deposition in biomonitoring studies and sample screening. Reference materials and environmental samples were dry ashed and pressed into pellets for introduction by laser ablation. No binder was used to reduce contamination. LA-MC-ICP-MS internal and external precisions were <1.1% and <0.3%, respectively, on both (207)Pb/(206)Pb and (208)Pb/(206)Pb ratios. LA-Q-ICP-MS internal precisions on (207)Pb/(206)Pb and (208)Pb/(206)Pb ratios were lower with values for the different sample sets <14.3% while external precisions were <2.9%. The level of external precision acquired in this study is high enough to distinguish between most modern Pb sources. LA-MC-ICP-MS measurements differed from thermal ionisation mass spectrometry (TIMS) values by 1% or less while the accuracy obtained using LA-Q-ICP-MS compared to solution MC-ICP-MS was 3.1% or better using a run bracketing (RB) mass bias correction method. Sample heterogeneity and detector switching when measuring (208)Pb by Q-ICP-MS are identified as sources of reduced analytical performance.

  8. Inorganic trace analysis by mass spectrometry

    NASA Astrophysics Data System (ADS)

    Becker, Johanna Sabine; Dietze, Hans-Joachim

    1998-10-01

    Mass spectrometric methods for the trace analysis of inorganic materials with their ability to provide a very sensitive multielemental analysis have been established for the determination of trace and ultratrace elements in high-purity materials (metals, semiconductors and insulators), in different technical samples (e.g. alloys, pure chemicals, ceramics, thin films, ion-implanted semiconductors), in environmental samples (waters, soils, biological and medical materials) and geological samples. Whereas such techniques as spark source mass spectrometry (SSMS), laser ionization mass spectrometry (LIMS), laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), glow discharge mass spectrometry (GDMS), secondary ion mass spectrometry (SIMS) and inductively coupled plasma mass spectrometry (ICP-MS) have multielemental capability, other methods such as thermal ionization mass spectrometry (TIMS), accelerator mass spectrometry (AMS) and resonance ionization mass spectrometry (RIMS) have been used for sensitive mono- or oligoelemental ultratrace analysis (and precise determination of isotopic ratios) in solid samples. The limits of detection for chemical elements using these mass spectrometric techniques are in the low ng g -1 concentration range. The quantification of the analytical results of mass spectrometric methods is sometimes difficult due to a lack of matrix-fitted multielement standard reference materials (SRMs) for many solid samples. Therefore, owing to the simple quantification procedure of the aqueous solution, inductively coupled plasma mass spectrometry (ICP-MS) is being increasingly used for the characterization of solid samples after sample dissolution. ICP-MS is often combined with special sample introduction equipment (e.g. flow injection, hydride generation, high performance liquid chromatography (HPLC) or electrothermal vaporization) or an off-line matrix separation and enrichment of trace impurities (especially for characterization of high-purity materials and environmental samples) is used in order to improve the detection limits of trace elements. Furthermore, the determination of chemical elements in the trace and ultratrace concentration range is often difficult and can be disturbed through mass interferences of analyte ions by molecular ions at the same nominal mass. By applying double-focusing sector field mass spectrometry at the required mass resolution—by the mass spectrometric separation of molecular ions from the analyte ions—it is often possible to overcome these interference problems. Commercial instrumental equipment, the capability (detection limits, accuracy, precision) and the analytical application fields of mass spectrometric methods for the determination of trace and ultratrace elements and for surface analysis are discussed.

  9. Optimization of chemical and instrumental parameters in hydride generation laser-induced breakdown spectrometry for the determination of arsenic, antimony, lead and germanium in aqueous samples.

    PubMed

    Yeşiller, Semira Unal; Yalçın, Serife

    2013-04-03

    A laser induced breakdown spectrometry hyphenated with on-line continuous flow hydride generation sample introduction system, HG-LIBS, has been used for the determination of arsenic, antimony, lead and germanium in aqueous environments. Optimum chemical and instrumental parameters governing chemical hydride generation, laser plasma formation and detection were investigated for each element under argon and nitrogen atmosphere. Arsenic, antimony and germanium have presented strong enhancement in signal strength under argon atmosphere while lead has shown no sensitivity to ambient gas type. Detection limits of 1.1 mg L(-1), 1.0 mg L(-1), 1.3 mg L(-1) and 0.2 mg L(-1) were obtained for As, Sb, Pb and Ge, respectively. Up to 77 times enhancement in detection limit of Pb were obtained, compared to the result obtained from the direct analysis of liquids by LIBS. Applicability of the technique to real water samples was tested through spiking experiments and recoveries higher than 80% were obtained. Results demonstrate that, HG-LIBS approach is suitable for quantitative analysis of toxic elements and sufficiently fast for real time continuous monitoring in aqueous environments. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. A positron emission tomograph based on LSO-APD modules with a sampling ADC read-out system for a students' advanced laboratory course.

    PubMed

    Schneider, Florian R; Mann, Alexander B; Konorov, Igor; Delso, Gaspar; Paul, Stephan; Ziegler, Sibylle I

    2012-06-01

    A one-day laboratory course on positron emission tomography (PET) for the education of physics students and PhD students in medical physics has been set up. In the course, the physical background and the principles of a PET scanner are introduced. Course attendees set the system in operation, calibrate it using a (22)Na point source and reconstruct different source geometries filled with (18)F. The PET scanner features an individual channel read-out of 96 lutetium oxyorthosilicate (LSO) scintillator crystals coupled to avalanche photodiodes (APD). The analog data of each APD are digitized by fast sampling analog to digital converters (SADC) and processed within field programmable gate arrays (FPGA) to extract amplitudes and time stamps. All SADCs are continuously sampling with a precise rate of 80MHz, which is synchronous for the whole system. The data is transmitted via USB to a Linux PC, where further processing and the image reconstruction are performed. The course attendees get an insight into detector techniques, modern read-out electronics, data acquisition and PET image reconstruction. In addition, a short introduction to some common software applications used in particle and high energy physics is part of the course. Copyright © 2011. Published by Elsevier GmbH.

  11. Applied 3D printing for microscopy in health science research

    NASA Astrophysics Data System (ADS)

    Brideau, Craig; Zareinia, Kourosh; Stys, Peter

    2015-03-01

    The rapid prototyping capability offered by 3D printing is considered advantageous for commercial applications. However, the ability to quickly produce precision custom devices is highly beneficial in the research laboratory setting as well. Biological laboratories require the manipulation and analysis of delicate living samples, thus the ability to create custom holders, support equipment, and adapters allow the extension of existing laboratory machines. Applications include camera adapters and stage sample holders for microscopes, surgical guides for tissue preparation, and small precision tools customized to unique specifications. Where high precision is needed, especially the reproduction of fine features, a printer with a high resolution is needed. However, the introduction of cheaper, lower resolution commercial printers have been shown to be more than adequate for less demanding projects. For direct manipulation of delicate samples, biocompatible raw materials are often required, complicating the printing process. This paper will examine some examples of 3D-printed objects for laboratory use, and provide an overview of the requirements for 3D printing for this application. Materials, printing resolution, production, and ease of use will all be reviewed with an eye to producing better printers and techniques for laboratory applications. Specific case studies will highlight applications for 3D-printed devices in live animal imaging for both microscopy and Magnetic Resonance Imaging.

  12. Advanced electronics for the CTF MEG system.

    PubMed

    McCubbin, J; Vrba, J; Spear, P; McKenzie, D; Willis, R; Loewen, R; Robinson, S E; Fife, A A

    2004-11-30

    Development of the CTF MEG system has been advanced with the introduction of a computer processing cluster between the data acquisition electronics and the host computer. The advent of fast processors, memory, and network interfaces has made this innovation feasible for large data streams at high sampling rates. We have implemented tasks including anti-alias filter, sample rate decimation, higher gradient balancing, crosstalk correction, and optional filters with a cluster consisting of 4 dual Intel Xeon processors operating on up to 275 channel MEG systems at 12 kHz sample rate. The architecture is expandable with additional processors to implement advanced processing tasks which may include e.g., continuous head localization/motion correction, optional display filters, coherence calculations, or real time synthetic channels (via beamformer). We also describe an electronics configuration upgrade to provide operator console access to the peripheral interface features such as analog signal and trigger I/O. This allows remote location of the acoustically noisy electronics cabinet and fitting of the cabinet with doors for improved EMI shielding. Finally, we present the latest performance results available for the CTF 275 channel MEG system including an unshielded SEF (median nerve electrical stimulation) measurement enhanced by application of an adaptive beamformer technique (SAM) which allows recognition of the nominal 20-ms response in the unaveraged signal.

  13. Intestinal parasites of endangered orangutans (Pongo pygmaeus) in Central and East Kalimantan, Borneo, Indonesia.

    PubMed

    Labes, E M; Hegglin, D; Grimm, F; Nurcahyo, W; Harrison, M E; Bastian, M L; Deplazes, P

    2010-01-01

    Faecal samples from 163 captive and semi-captive individuals, 61 samples from wild individuals and 38 samples from captive groups of Bornean orangutans (Pongo pygmaeus) in Kalimantan, Indonesia, were collected during one rainy season (November 2005-May 2006) and screened for intestinal parasites using sodium acetate-acetic acid-formalin-concentration (SAFC), sedimentation, flotation, McMaster- and Baermann techniques. We aimed to identify factors influencing infection risk for specific intestinal parasites in wild orangutans and individuals living in captivity. Various genera of Protozoa (including Entamoeba, Endolimax, Iodamoeba, Balantidium, Giardia and Blastocystis), nematodes (such as Strongyloides, Trichuris, Ascaris, Enterobius, Trichostrongylus and hookworms) and one trematode (a dicrocoeliid) were identified. For the first time, the cestode Hymenolepis was detected in orangutans. Highest prevalences were found for Strongyloides (individuals 37%; groups 58%), hookworms (41%; 58%), Balantidium (40%; 61%), Entamoeba coli (29%; 53%) and a trichostrongylid (13%; 32%). In re-introduction centres, infants were at higher risk of infection with Strongyloides than adults. Infection risk for hookworms was significantly higher in wild males compared with females. In groups, the centres themselves had a significant influence on the infection risk for Balantidium. Ranging patterns of wild orangutans, overcrowding in captivity and a shift of age composition in favour of immatures seemed to be the most likely factors leading to these results.

  14. Recommendations for representative ballast water sampling

    NASA Astrophysics Data System (ADS)

    Gollasch, Stephan; David, Matej

    2017-05-01

    Until now, the purpose of ballast water sampling studies was predominantly limited to general scientific interest to determine the variety of species arriving in ballast water in a recipient port. Knowing the variety of species arriving in ballast water also contributes to the assessment of relative species introduction vector importance. Further, some sampling campaigns addressed awareness raising or the determination of organism numbers per water volume to evaluate the species introduction risk by analysing the propagule pressure of species. A new aspect of ballast water sampling, which this contribution addresses, is compliance monitoring and enforcement of ballast water management standards as set by, e.g., the IMO Ballast Water Management Convention. To achieve this, sampling methods which result in representative ballast water samples are essential. We recommend such methods based on practical tests conducted on two commercial vessels also considering results from our previous studies. The results show that different sampling approaches influence the results regarding viable organism concentrations in ballast water samples. It was observed that the sampling duration (i.e., length of the sampling process), timing (i.e., in which point in time of the discharge the sample is taken), the number of samples and the sampled water quantity are the main factors influencing the concentrations of viable organisms in a ballast water sample. Based on our findings we provide recommendations for representative ballast water sampling.

  15. Concepts and methods in neuromodulation and functional electrical stimulation: an introduction.

    PubMed

    Holsheimer, J

    1998-04-01

    This article introduces two clinical fields in which stimulation is applied to the nervous system: neuromodulation and functional electrical stimulation. The concepts underlying these fields and their main clinical applications, as well as the methods and techniques used in each field, are described. Concepts and techniques common in one field that might be beneficial to the other are discussed. 1998 Blackwell Science, Inc.

  16. Recording Fathometer Techniques for Hydrilla Distribution and Biomass Studies.

    DTIC Science & Technology

    1983-01-01

    DISTRIBUTION AND BIOMASS STUDIES PART I: FATHOMETER STUDIES Introduction . 1. Aquatic macrophytes are an integral component of freshwater ecosystems...larger bodies of water . Color and infrared photography have been employed successfully as remote sensing techniques to map the coverage of aquatic ...Fox, editors. Water quality manage- ment through biological control. Rep. No. ENV-07-75-1. Carlander, K. D. 1977. Handbook of freshwater fishery biology

  17. Search for dark matter with the bolometric technique

    NASA Astrophysics Data System (ADS)

    Giuliani, Andrea

    2014-07-01

    After a concise introduction about the dark matter issue and a discussion of the problematics related to its direct detection, the bolometric technique is presented in this context, with a special focus on double-readout devices. The bolometric experiments for the search for dark matter are then described and reviewed. Their present and future roles are discussed, arguing about pros and cons of this technology.

  18. The Use of Brain Electrophysiology Techniques To Study Language: A Basic Guide for the Beginning Consumer of Electrophysiology Information.

    ERIC Educational Resources Information Center

    Molfese, Dennis L.; Molfese, Victoria J.; Kelly, Spencer

    2001-01-01

    This article provides an introduction to the use of event-related potential (ERP) approaches to study language processes. First, a brief history of the emergence of this technology is presented, followed by definitions, a theoretical overview, and a practical guide to conducting ERP studies. Examples of language studies that use this technique are…

  19. Intracytoplasmic sperm injection: a state of the art technique.

    PubMed

    Mansour, R

    1998-01-01

    Of the micromanipulation techniques developed in the twentieth century, intracytoplasmic sperm injection (ICSI) has been the major breakthrough in the field of assisted fertilization. This article reviews the indications for the use of ICSI, its clinical application, the establishment of an ICSI programme including protocol and the results obtained since the introduction of ICSI and the potential risks. In addition, intracytoplasmic spermatid injection is briefly discussed.

  20. Thin Film Research. Volume 2

    DTIC Science & Technology

    1985-05-30

    consisting of quarterwave layers by detecting the -- extrema of transmission or reflectance at a particular wavelength. This method is extremely stable for the...technique, which is based on an envelope method , and gives some experimental *results. L"( iL -2- I. Introduction The refractive index and the...constants determination :ecnnique by computer simulation, we have applied the method to various layers of titanium dioxide. This technique can then

  1. Introduction to the physics and techniques of remote sensing

    NASA Technical Reports Server (NTRS)

    Elachi, Charles

    1987-01-01

    This book presents a comprehensive overview of the basics behind remote-sensing physics, techniques, and technology. The physics of wave/matter interactions, techniques of remote sensing across the electromagnetic spectrum, and the concepts behind remote sensing techniques now established and future ones under development are discussed. Applications of remote sensing are described for a wide variety of earth and planetary atmosphere and surface sciences. Solid surface sensing across the electromagnetic spectrum, ocean surface sensing, basic principles of atmospheric sensing and radiative transfer, and atmospheric remote sensing in the microwave, millimeter, submillimeter, and infrared regions are examined.

  2. Effect of geometrical parameters on pressure distributions of impulse manufacturing technologies

    NASA Astrophysics Data System (ADS)

    Brune, Ryan Carl

    Impulse manufacturing techniques constitute a growing field of methods that utilize high-intensity pressure events to conduct useful mechanical operations. As interest in applying this technology continues to grow, greater understanding must be achieved with respect to output pressure events in both magnitude and distribution. In order to address this need, a novel pressure measurement has been developed called the Profile Indentation Pressure Evaluation (PIPE) method that systematically analyzes indentation patterns created with impulse events. Correlation with quasi-static test data and use of software-assisted analysis techniques allows for colorized pressure maps to be generated for both electromagnetic and vaporizing foil actuator (VFA) impulse forming events. Development of this technique aided introduction of a design method for electromagnetic path actuator systems, where key geometrical variables are considered using a newly developed analysis method, which is called the Path Actuator Proximal Array (PAPA) pressure model. This model considers key current distribution and proximity effects and interprets generated pressure by considering the adjacent conductor surfaces as proximal arrays of individual conductors. According to PIPE output pressure analysis, the PAPA model provides a reliable prediction of generated pressure for path actuator systems as local geometry is changed. Associated mechanical calculations allow for pressure requirements to be calculated for shearing, flanging, and hemming operations, providing a design process for such cases. Additionally, geometry effect is investigated through a formability enhancement study using VFA metalworking techniques. A conical die assembly is utilized with both VFA high velocity and traditional quasi-static test methods on varied Hasek-type sample geometries to elicit strain states consistent with different locations on a forming limit diagram. Digital image correlation techniques are utilized to measure major and minor strains for each sample type to compare limit strain results. Overall testing indicated decreased formability at high velocity for 304 DDQ stainless steel and increased formability at high velocity for 3003-H14 aluminum. Microstructural and fractographic analysis helped dissect and analyze the observed differences in these cases. Overall, these studies comprehensively explore the effects of geometrical parameters on magnitude and distribution of impulse manufacturing generated pressure, establishing key guidelines and models for continued development and implementation in commercial applications.

  3. Bulk- and surface-modified combinable PDMS capillary sensor array as an easy-to-use sensing device with enhanced sensitivity to elevated concentrations of multiple serum sample components.

    PubMed

    Fujii, Yuji; Henares, Terence G; Kawamura, Kunio; Endo, Tatsuro; Hisamoto, Hideaki

    2012-04-21

    To enhance sensitivity and facilitate easy sample introduction into a combinable poly(dimethylsiloxane) (PDMS) capillary (CPC) sensor array, PDMS was modified in bulk and on its surface to prepare "black" PDMS coated with a silver layer and self-assembled monolayer (SAM). India ink, a traditional Japanese black ink, was added to the PDMS pre-polymer for bulk modification. The surface was modified by a silver mirror reaction followed by SAM formation using cysteine. These modifications enhanced the fluorescence signals by reflecting them from the surface and reducing background interference. A decrease in the water contact angle led to enhanced sensitivity and easy sample introduction. Furthermore, a CPC sensor array for multiplex detection of serum sample components was prepared that could quantify the analytes glucose, potassium, and alkaline phosphatase (ALP). When serum samples were introduced by capillary action, the CPC sensor array showed fluorescence responses for each analyte and successfully identified the components with elevated concentrations in the serum samples.

  4. Development of an automated high temperature valveless injection system for on-line gas chromatography

    NASA Astrophysics Data System (ADS)

    Kreisberg, N. M.; Worton, D. R.; Zhao, Y.; Isaacman, G.; Goldstein, A. H.; Hering, S. V.

    2014-07-01

    A reliable method of sample introduction is presented for on-line gas chromatography with a special application to in-situ field portable atmospheric sampling instruments. A traditional multi-port valve is replaced with a controlled pressure switching device that offers the advantage of long term reliability and stable sample transfer efficiency. An engineering design model is presented and tested that allows customizing the interface for other applications. Flow model accuracy is within measurement accuracy (1%) when parameters are tuned for an ambient detector and 15% accurate when applied to a vacuum based detector. Laboratory comparisons made between the two methods of sample introduction using a thermal desorption aerosol gas chromatograph (TAG) show approximately three times greater reproducibility maintained over the equivalent of a week of continuous sampling. Field performance results for two versions of the valveless interface used in the in-situ instrument demonstrate minimal trending and a zero failure rate during field deployments ranging up to four weeks of continuous sampling. Extension of the VLI to dual collection cells is presented with less than 3% cell-to-cell carry-over.

  5. A Guide to Making an Audio Tape.

    ERIC Educational Resources Information Center

    Jobe, Holly; Cannon, Glenn

    This brief introduction to the use of audiotape recorders in educational settings provides basic information on operational procedures and recording techniques for voice, music, dubbing, and pulsing. Audiotape editing and splicing are also explained. (RAO)

  6. The Gentle Art of Classroom Discipline.

    ERIC Educational Resources Information Center

    Jones, Frederic H.

    1979-01-01

    Gives a general introduction to the Classroom Management Training Program approach to maintaining discipline in the classroom and provides more extensive discussion of three aspects of the method--limit setting, the incentive system, and instructional techniques. (IRT)

  7. Fourier transform ion cyclotron resonance mass spectrometry

    NASA Astrophysics Data System (ADS)

    Marshall, Alan G.

    1998-06-01

    As for Fourier transform infrared (FT-IR) interferometry and nuclear magnetic resonance (NMR) spectroscopy, the introduction of pulsed Fourier transform techniques revolutionized ion cyclotron resonance mass spectrometry: increased speed (factor of 10,000), increased sensitivity (factor of 100), increased mass resolution (factor of 10,000-an improvement not shared by the introduction of FT techniques to IR or NMR spectroscopy), increased mass range (factor of 500), and automated operation. FT-ICR mass spectrometry is the most versatile technique for unscrambling and quantifying ion-molecule reaction kinetics and equilibria in the absence of solvent (i.e., the gas phase). In addition, FT-ICR MS has the following analytically important features: speed (~1 second per spectrum); ultrahigh mass resolution and ultrahigh mass accuracy for analysis of mixtures and polymers; attomole sensitivity; MSn with one spectrometer, including two-dimensional FT/FT-ICR/MS; positive and/or negative ions; multiple ion sources (especially MALDI and electrospray); biomolecular molecular weight and sequencing; LC/MS; and single-molecule detection up to 108 Dalton. Here, some basic features and recent developments of FT-ICR mass spectrometry are reviewed, with applications ranging from crude oil to molecular biology.

  8. Liposuction: 25 years of experience in 26,259 patients using different devices.

    PubMed

    Triana, Lina; Triana, Carlos; Barbato, Carlos; Zambrano, Marco

    2009-01-01

    The development of liposuction provided plastic surgeons with a safe and effective way to sculpt the human figure. The techniques and instrumentation used in the performance of liposuction have evolved significantly since its introduction. The authors review their experience with different liposuction techniques over the past 25 years. Data from patients who had undergone liposuction were collected from the personal databases of four different surgeons and from the database at the Corpus and Rostrum Plastic Surgery Clinic in Cali, Colombia. A retrospective review was conducted and the results from different liposuction techniques were compared. A total of 26,259 patient charts were reviewed. The results showed that 5% of patients experienced a postsurgical seroma. Postsurgical fibrosis developed to some degree in 2.3% of patients. Anemia was present in 18% of all patients and in 60% of those patients who underwent dry liposuction. Ninety percent of patients reported postoperative pain. The incidence of deep vein thrombosis was 0.03%, as was the incidence of pulmonary embolism. Mortality was 0.01% and was mainly caused by pulmonary embolism. Patient satisfaction was similar for all of the described techniques. The incidence of anemia was reduced significantly in patients undergoing tumescent liposuction versus dry liposuction. However, the occurrence of seroma increased with the introduction of tumescent liposuction. The incidence of postoperative pain and fibrosis was similar for all liposuction techniques reviewed. The aesthetic results obtained using ultrasound- or laser-assisted liposuction were similar to those obtaining using other techniques.

  9. Probabilistic Inference: Task Dependency and Individual Differences of Probability Weighting Revealed by Hierarchical Bayesian Modeling

    PubMed Central

    Boos, Moritz; Seer, Caroline; Lange, Florian; Kopp, Bruno

    2016-01-01

    Cognitive determinants of probabilistic inference were examined using hierarchical Bayesian modeling techniques. A classic urn-ball paradigm served as experimental strategy, involving a factorial two (prior probabilities) by two (likelihoods) design. Five computational models of cognitive processes were compared with the observed behavior. Parameter-free Bayesian posterior probabilities and parameter-free base rate neglect provided inadequate models of probabilistic inference. The introduction of distorted subjective probabilities yielded more robust and generalizable results. A general class of (inverted) S-shaped probability weighting functions had been proposed; however, the possibility of large differences in probability distortions not only across experimental conditions, but also across individuals, seems critical for the model's success. It also seems advantageous to consider individual differences in parameters of probability weighting as being sampled from weakly informative prior distributions of individual parameter values. Thus, the results from hierarchical Bayesian modeling converge with previous results in revealing that probability weighting parameters show considerable task dependency and individual differences. Methodologically, this work exemplifies the usefulness of hierarchical Bayesian modeling techniques for cognitive psychology. Theoretically, human probabilistic inference might be best described as the application of individualized strategic policies for Bayesian belief revision. PMID:27303323

  10. Temperature Increase during Different Post Space Preparation Systems: An In Vitro Study

    PubMed Central

    Nazari Moghadam, Kiumars; Shahab, Shahriar; Shirvani, Soghra; Kazemi, Ali

    2011-01-01

     INTRODUCTION: The purpose of this study was to evaluate external root surface temperature rise during post space preparation using LA Axxess bur, Beefill pack System, and Peeso Reamer drill. MATERIALS AND METHODS: The distal canals of forty-five extracted human permanent mandibular first molars were instrumented in crown-apical manner and obturated with lateral condensation technique. Teeth were then randomly divided into three groups according to post space preparation technique including: group 1. LA Axxess bur (Sybronendo Co., CA, USA), group 2 Beefill pack System (VD W Co., Munich, Germany) and group 3 Peeso Reamer drill (Mani Co., Tochigi-ken, Japan). Temperature was measured by means of digital thermometer MT-405 (Comercio Co., Sao Paulo, Brazil) which was installed on the root surfaces. Data was collected and submitted to one-way ANOVA and Post hoc analysis. RESULTS: Root surface temperatures were found to be significantly higher (7.3±2.7 vs. 4.3±2.1 and 4±2.4,) in samples of Beefill pack System compared with the two other groups (P<0.02). CONCLUSION: Using Beefill pack System during post space preparation may be potentially hazardous for periodontal tissues. PMID:24778690

  11. Nanomechanics of Cells and Biomaterials Studied by Atomic Force Microscopy.

    PubMed

    Kilpatrick, Jason I; Revenko, Irène; Rodriguez, Brian J

    2015-11-18

    The behavior and mechanical properties of cells are strongly dependent on the biochemical and biomechanical properties of their microenvironment. Thus, understanding the mechanical properties of cells, extracellular matrices, and biomaterials is key to understanding cell function and to develop new materials with tailored mechanical properties for tissue engineering and regenerative medicine applications. Atomic force microscopy (AFM) has emerged as an indispensable technique for measuring the mechanical properties of biomaterials and cells with high spatial resolution and force sensitivity within physiologically relevant environments and timescales in the kPa to GPa elastic modulus range. The growing interest in this field of bionanomechanics has been accompanied by an expanding array of models to describe the complexity of indentation of hierarchical biological samples. Furthermore, the integration of AFM with optical microscopy techniques has further opened the door to a wide range of mechanotransduction studies. In recent years, new multidimensional and multiharmonic AFM approaches for mapping mechanical properties have been developed, which allow the rapid determination of, for example, cell elasticity. This Progress Report provides an introduction and practical guide to making AFM-based nanomechanical measurements of cells and surfaces for tissue engineering applications. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Investigation of laser Doppler anemometry in developing a velocity-based measurement technique

    NASA Astrophysics Data System (ADS)

    Jung, Ki Won

    2009-12-01

    Acoustic properties, such as the characteristic impedance and the complex propagation constant, of porous materials have been traditionally characterized based on pressure-based measurement techniques using microphones. Although the microphone techniques have evolved since their introduction, the most general form of the microphone technique employs two microphones in characterizing the acoustic field for one continuous medium. The shortcomings of determining the acoustic field based on only two microphones can be overcome by using numerous microphones. However, the use of a number of microphones requires a careful and intricate calibration procedure. This dissertation uses laser Doppler anemometry (LDA) to establish a new measurement technique which can resolve issues that microphone techniques have: First, it is based on a single sensor, thus the calibration is unnecessary when only overall ratio of the acoustic field is required for the characterization of a system. This includes the measurements of the characteristic impedance and the complex propagation constant of a system. Second, it can handle multiple positional measurements without calibrating the signal at each position. Third, it can measure three dimensional components of velocity even in a system with a complex geometry. Fourth, it has a flexible adaptability which is not restricted to a certain type of apparatus only if the apparatus is transparent. LDA is known to possess several disadvantages, such as the requirement of a transparent apparatus, high cost, and necessity of seeding particles. The technique based on LDA combined with a curvefitting algorithm is validated through measurements on three systems. First, the complex propagation constant of the air is measured in a rigidly terminated cylindrical pipe which has very low dissipation. Second, the radiation impedance of an open-ended pipe is measured. These two parameters can be characterized by the ratio of acoustic field measured at multiple locations. Third, the power dissipated in a variable RLC load is measured. The three experiments validate the LDA technique proposed. The utility of the LDA method is then extended to the measurement of the complex propagation constant of the air inside a 100 ppi reticulated vitreous carbon (RVC) sample. Compared to measurements in the available studies, the measurement with the 100 ppi RVC sample supports the LDA technique in that it can achieve a low uncertainty in the determined quantity. This dissertation concludes with using the LDA technique for modal decomposition of the plane wave mode and the (1,1) mode that are driven simultaneously. This modal decomposition suggests that the LDA technique surpasses microphone-based techniques, because they are unable to determine the acoustic field based on an acoustic model with unconfined propagation constants for each modal component.

  13. Practical limitations of single particle ICP-MS in the determination of nanoparticle size distributions and dissolution: case of rare earth oxides.

    PubMed

    Fréchette-Viens, Laurie; Hadioui, Madjid; Wilkinson, Kevin J

    2017-01-15

    The applicability of single particle ICP-MS (SP-ICP-MS) for the analysis of nanoparticle size distributions and the determination of particle numbers was evaluated using the rare earth oxide, La 2 O 3 , as a model particle. The composition of the storage containers, as well as the ICP-MS sample introduction system were found to significantly impact SP-ICP-MS analysis. While La 2 O 3 nanoparticles (La 2 O 3 NP) did not appear to interact strongly with sample containers, adsorptive losses of La 3+ (over 24h) were substantial (>72%) for fluorinated ethylene propylene bottles as opposed to polypropylene (<10%). Furthermore, each part of the sample introduction system (nebulizers made of perfluoroalkoxy alkane (PFA) or glass, PFA capillary tubing, and polyvinyl chloride (PVC) peristaltic pump tubing) contributed to La 3+ adsorptive losses. On the other hand, the presence of natural organic matter in the nanoparticle suspensions led to a decreased adsorptive loss in both the sample containers and the introduction system, suggesting that SP-ICP-MS may nonetheless be appropriate for NP analysis in environmental matrices. Coupling of an ion-exchange resin to the SP-ICP-MS led to more accurate determinations of the La 2 O 3 NP size distributions. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Analytical toxicology.

    PubMed

    Flanagan, R J; Widdop, B; Ramsey, J D; Loveland, M

    1988-09-01

    1. Major advances in analytical toxicology followed the introduction of spectroscopic and chromatographic techniques in the 1940s and early 1950s and thin layer chromatography remains important together with some spectrophotometric and other tests. However, gas- and high performance-liquid chromatography together with a variety of immunoassay techniques are now widely used. 2. The scope and complexity of forensic and clinical toxicology continues to increase, although the compounds for which emergency analyses are needed to guide therapy are few. Exclusion of the presence of hypnotic drugs can be important in suspected 'brain death' cases. 3. Screening for drugs of abuse has assumed greater importance not only for the management of the habituated patient, but also in 'pre-employment' and 'employment' screening. The detection of illicit drug administration in sport is also an area of increasing importance. 4. In industrial toxicology, the range of compounds for which blood or urine measurements (so called 'biological monitoring') can indicate the degree of exposure is increasing. The monitoring of environmental contaminants (lead, chlorinated pesticides) in biological samples has also proved valuable. 5. In the near future a consensus as to the units of measurement to be used is urgently required and more emphasis will be placed on interpretation, especially as regards possible behavioural effects of drugs or other poisons. Despite many advances in analytical techniques there remains a need for reliable, simple tests to detect poisons for use in smaller hospital and other laboratories.

  15. Microwave Three-Wave Mixing Experiments for Chirality Determination: Current Status

    NASA Astrophysics Data System (ADS)

    Perez, Cristobal; Shubert, V. Alvin; Schmitz, David; Medcraft, Chris; Krin, Anna; Schnell, Melanie

    2015-06-01

    Microwave three-wave mixing experiments have been shown to provide a novel and sensitive way to generate and measure enantiomer-specific molecular signatures. The handedness of the sample can be obtained from the phase of the molecular free induction decay whereas the enantiomeric excess can be determined by the amplitude of the chiral signal. After the introduction of this technique by Patterson et al. remarkable improvements have been realized and experimental strategies for both absolute phase determination and enantiomeric excess have been presented. This technique has been also successfully implemented at higher microwave frequencies. Here we present the current status of this technique as well future directions and perspectives. This will be illustrated through our systematic study of chiral terpenes as well as preliminary results in molecular clusters. Patterson, D.; Schnell, M.; Doyle, J. M. Enantiomer-Specific Detection of Chiral Molecules via Microwave Spectroscopy. Nature 2013, 497, 475-477. Patterson, D.; Doyle, J. M. Sensitive Chiral Analysis via Microwave Three-Wave Mixing. Phys. Rev. Lett. 2013, 111, 023008. Shubert, V. A.; Schmitz, D.; Patterson, D.; Doyle, J. M.; Schnell, M. Identifying Enantiomers in Mixtures of Chiral Molecules with Broadband Microwave Spectroscopy. Angew. Chem. Int. Ed. 2014, 53, 1152-1155. Lobsiger, S.; Perez, C.; Evangelisti, L.; Lehmann, K. K.; Pate, B. H. Molecular Structure and Chirality Detection by Fourier Transform Microwave Spectroscopy. J. Phys. Chem. Lett. 2014, 6, 196-200.

  16. Feeding Practices and Infant Growth: Quantifying the Effects of Breastfeeding Termination and Complementary Food Introduction on BMI z-Score Growth Velocity through Growth Curve Models.

    PubMed

    Horodynski, Mildred A; Pierce, Steven J; Reyes-Gastelum, David; Olson, Beth; Shattuck, Mackenzie

    2017-12-01

    Infant feeding practices are a focus of early obesity prevention. We tested whether infant growth velocity increased after breastfeeding termination and complementary food introduction. Our secondary analysis included a sample of 547 mother-infant dyads from a longitudinal randomized controlled trial conducted in Michigan and Colorado. Infant anthropometrics at birth, baseline, and 6- and 12-month follow-up were standardized to BMI-for-age z-score (ZBMI) according to World Health Organization (WHO) growth charts. We used growth curve models with time-varying predictors to quantify effects of breastfeeding termination and timing of complementary food introduction on growth velocity. Median breastfeeding duration was 2.0 months [confidence interval (CI) = 2.0-2.5]; median introduction of complementary foods occurred at 3.0 months (CI = 2.8-3.2). Breastfed infants not yet introduced to complementary foods had an average ZBMI growth velocity of 0.050 (CI = -0.013 to 0.113) z-score units per month [zpm], not significantly faster than WHO growth trajectory (p = 0.118) defined as 0 zpm. Breastfeeding termination had negligible effect on ZBMI growth velocity (γ 11  = 0.001, CI = -0.027 to 0.030, p = 0.927). Introduction of complementary foods increased ZBMI growth velocity relative to an average child in the sample, but not significantly (γ 12  = 0.033, CI = -0.034 to 0.100, p = 0.334). Growth velocities for infants receiving complementary foods both before and after breastfeeding termination were significantly faster than the WHO growth trajectory (0.083 zpm, CI = 0.052-0.114, and 0.084 zpm, CI = 0.064-0.105, respectively, p's < 0.001). Average postcomplementary food introduction growth velocity was significantly higher than WHO growth trajectory, but did not differ from the sample's initial average trajectory. Growth curve models can accurately estimate effects of feeding practices on infant growth to direct obesity prevention efforts.

  17. Laser-based irradiation apparatus and methods for monitoring the dose-rate response of semiconductor devices

    DOEpatents

    Horn, Kevin M [Albuquerque, NM

    2006-03-28

    A scanned, pulsed, focused laser irradiation apparatus can measure and image the photocurrent collection resulting from a dose-rate equivalent exposure to infrared laser light across an entire silicon die. Comparisons of dose-rate response images or time-delay images from before, during, and after accelerated aging of a device, or from periodic sampling of devices from fielded operational systems allows precise identification of those specific age-affected circuit structures within a device that merit further quantitative analysis with targeted materials or electrical testing techniques. Another embodiment of the invention comprises a broad-beam, dose rate-equivalent exposure apparatus. The broad-beam laser irradiation apparatus can determine if aging has affected the device's overall functionality. This embodiment can be combined with the synchronized introduction of external electrical transients into a device under test to simulate the electrical effects of the surrounding circuitry's response to a radiation exposure.

  18. Conformational energy calculations on polypeptides and proteins: use of a statistical mechanical procedure for evaluating structure and properties.

    PubMed

    Scheraga, H A; Paine, G H

    1986-01-01

    We are using a variety of theoretical and computational techniques to study protein structure, protein folding, and higher-order structures. Our earlier work involved treatments of liquid water and aqueous solutions of nonpolar and polar solutes, computations of the stabilities of the fundamental structures of proteins and their packing arrangements, conformations of small cyclic and open-chain peptides, structures of fibrous proteins (collagen), structures of homologous globular proteins, introduction of special procedures as constraints during energy minimization of globular proteins, and structures of enzyme-substrate complexes. Recently, we presented a new methodology for predicting polypeptide structure (described here); the method is based on the calculation of the probable and average conformation of a polypeptide chain by the application of equilibrium statistical mechanics in conjunction with an adaptive, importance sampling Monte Carlo algorithm. As a test, it was applied to Met-enkephalin.

  19. An Introductory "How-to" Guide for Incorporating Microbiome Research into Integrative and Comparative Biology.

    PubMed

    Kohl, Kevin D

    2017-10-01

    Research on host-associated microbial communities has grown rapidly. Despite the great body of work, inclusion of microbiota-related questions into integrative and comparative biology is still lagging behind other disciplines. The purpose of this paper is to offer an introduction into the basic tools and techniques of host-microbe research. Specifically, what considerations should be made before embarking on such projects (types of samples, types of controls)? How is microbiome data analyzed and integrated with data measured from the hosts? How can researchers experimentally manipulate the microbiome? With this information, integrative and comparative biologists should be able to include host-microbe studies into their research and push the boundaries of both fields. © The Author 2017. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.

  20. Optical Spectra Tuning of All-Glass Photonic Bandgap Fiber Infiltrated with Silver Fast-Ion-Conducting Glasses.

    PubMed

    Konidakis, Ioannis; Pissadakis, Stavros

    2014-08-07

    Silver iodide metaphosphate glasses of the x AgI + (1- x )AgPO₃ family are embedded inside the air capillaries of a commercial silica photonic crystal fiber (PCF) by means of vacuum-assisted infiltration technique. In this paper, we report on tuning the photonic bandgap (PBG) guidance characteristics of the fabricated all-glass photonic bandgap fibers, by varying the composition of the fast-ion-conducting phosphate glass infiltration medium. Doping AgPO₃ metaphosphate glass with AgI significantly alters the PBG guidance patterns in the examined range between 350 and 1750 nm, as it leads to the introduction of numerous additional transmission stop-bands, while affecting scattering dependant losses. The effect of phosphate glass cooling method during sample fabrication on the transmission behavior of the x AgI + (1- x )AgPO₃/PCFs is also considered.

  1. Environmental applications of single collector high resolution ICP-MS.

    PubMed

    Krachler, Michael

    2007-08-01

    The number of environmental applications of single collector high resolution ICP-MS (HR-ICP-MS) has increased rapidly in recent years. There are many factors that contribute to make HR-ICP-MS a very powerful tool in environmental analysis. They include the extremely low detection limits achievable, tremendously high sensitivity, the ability to separate ICP-MS signals of the analyte from spectral interferences, enabling the reliable determination of many trace elements, and the reasonable precision of isotope ratio measurements. These assets are improved even further using high efficiency sample introduction systems. Therefore, external factors such as the stability of laboratory blanks are frequently the limiting factor in HR-ICP-MS analysis rather than the detection power. This review aims to highlight the most recent applications of HR-ICP-MS in this sector, focusing on matrices and applications where the superior capabilities of the instrumental technique are most useful and often ultimately required.

  2. Investigation on microfluidic particles manipulation by holographic 3D tracking strategies

    NASA Astrophysics Data System (ADS)

    Cacace, Teresa; Paturzo, Melania; Memmolo, Pasquale; Vassalli, Massimo; Fraldi, Massimiliano; Mensitieri, Giuseppe; Ferraro, Pietro

    2017-06-01

    We demonstrate a 3D holographic tracking method to investigate particles motion in a microfluidic channel while unperturbed while inducing their migration through microfluidic manipulation. Digital holography (DH) in microscopy is a full-field, label-free imaging technique able to provide quantitative phase-contrast. The employed 3D tracking method is articulated in steps. First, the displacements along the optical axis are assessed by numerical refocusing criteria. In particular, an automatic refocusing method to recover the particles axial position is implemented employing a contrast-based refocusing criterion. Then, the transverse position of the in-focus object is evaluated through quantitative phase map segmentation methods and centroid-based 2D tracking strategy. The introduction of DH is thus suggested as a powerful approach for control of particles and biological samples manipulation, as well as a possible aid to precise design and implementation of advanced lab-on-chip microfluidic devices.

  3. Immunoaffinity chromatography: an introduction to applications and recent developments

    PubMed Central

    Moser, Annette C

    2010-01-01

    Immunoaffinity chromatography (IAC) combines the use of LC with the specific binding of antibodies or related agents. The resulting method can be used in assays for a particular target or for purification and concentration of analytes prior to further examination by another technique. This review discusses the history and principles of IAC and the various formats that can be used with this method. An overview is given of the general properties of antibodies and of antibody-production methods. The supports and immobilization methods used with antibodies in IAC and the selection of application and elution conditions for IAC are also discussed. Several applications of IAC are considered, including its use in purification, immunodepletion, direct sample analysis, chromatographic immunoassays and combined analysis methods. Recent developments include the use of IAC with CE or MS, ultrafast immunoextraction methods and the use of immunoaffinity columns in microanalytical systems. PMID:20640220

  4. Platelet-Rich Fibrin: An Autologous Fibrin Matrix in Surgical Procedures: A Case Report and Review of Literature

    PubMed Central

    Eshghpour, Majid; Majidi, Mohamad Reza; Nejat, Amir Hossein

    2012-01-01

    Introduction: The healing process after surgery is a challenging issue for surgeons. Various materials and techniques have been developed to facilitate this process and reduce its period. Fibrin adhesives are often used in cardiothoracic and vascular surgery to seal diffuse microvascular bleeding and in general and plastic surgery to seal wound borders. This Case report and literature review will introduce the various usages of platelet-rich fibrin in different surgical procedures and the method of producing the matrix. Case Report: A 24-year old man with periorbital skin avulsion treated with PRF membrane has been reported and discussed in this paper. Conclusion: Platelet-rich fibrin is a natural autologous fibrin matrix, which can be produced with a simple blood sample and a table centrifuge. The material has been used in a wide range of surgical procedures to shorten the healing period and reduce post-surgical complications. PMID:24303410

  5. Channeling implantation of high energy carbon ions in a diamond crystal: Determination of the induced crystal amorphization

    NASA Astrophysics Data System (ADS)

    Erich, M.; Kokkoris, M.; Fazinić, S.; Petrović, S.

    2018-02-01

    This work reports on the induced diamond crystal amorphization by 4 MeV carbon ions implanted in the 〈1 0 0〉 oriented crystal and its determination by application of RBS/C and EBS/C techniques. The spectra from the implanted samples were recorded for 1.2, 1.5, 1.75 and 1.9 MeV protons. For the two latter ones the strong resonance of the nuclear elastic scattering 12C(p,p0)12C at 1.737 MeV was explored. The backscattering channeling spectra were successfully fitted and the ion beam induced crystal amorphization depth profile was determined using a phenomenological approach, which is based on the properly defined Gompertz type dechanneling functions for protons in the 〈1 0 0〉 diamond crystal channels and the introduction of the concept of ion beam amorphization, which is implemented through our newly developed computer code CSIM.

  6. So you want to do research? 3. An introduction to qualitative methods.

    PubMed

    Meadows, Keith A

    2003-10-01

    This article describes some of the key issues in the use of qualitative research methods. Starting with a description of what qualitative research is and outlining some of the distinguishing features between quantitative and qualitative research, examples of the type of setting where qualitative research can be applied are provided. Methods of collecting information through in-depth interviews and group discussions are discussed in some detail, including issues around sampling and recruitment, the use of topic guides and techniques to encourage participants to talk openly. An overview on the analysis of qualitative data discusses aspects on data reduction, display and drawing conclusions from the data. Approaches to ensuring rigour in the collection, analysis and reporting of qualitative research are discussed and the concepts of credibility, transferability, dependability and confirmability are described. Finally, guidelines for the reporting of qualitative research are outlined and the need to write for a particular audience is discussed.

  7. Catheter port cleansing techniques and the entry of povidone-iodine into the epidural space.

    PubMed

    Paice, J A; DuPen, A; Schwertz, D

    1999-04-01

    To determine whether three epidural catheter port cleansing techniques used to apply a povidone-iodine solution differed with respect to the introduction of this solution through the epidural catheter. Experimental. Laboratory. Five DuPen (Davol, Cranston, RI) epidural catheters. Five DuPen epidural catheters each were cleansed twice with (a) a commercially available 10% povidone-iodine swabstick, (b) a commercially available pledget impregnated with 10% povidone-iodine, and (c) a gauze pad saturated with 10% povidone-iodine. The order of cleansing was randomized. Each solution was used to clean the port for 30 seconds, and the port was allowed to dry for 30 seconds, similar to the technique used in the clinical setting. After cleaning the catheter port, water was injected through the catheter, and the solution from the tip of the catheter was analyzed using absorbance spectrophotometry. Cleansing techniques, presence of povidone-iodine in catheter. A statistically significant difference existed between the three cleansing techniques, with the pledget yielding the lowest values of povidone-iodine contamination of the epidural catheter (Freidman test, p = 0.02). Use of pledgets allowed the least amount of povidone-iodine to enter the epidural catheter as compared with the swabsticks or gauze pads. Commercially available pledgets used to cleanse catheter injection ports may limit the introduction of 10% povidone-iodine into the epidural or intrathecal space.

  8. [Determination of heavy metals for RoHS compliance by ICP-OES spectrometry coupled with microwave extraction system].

    PubMed

    Hua, Li; Wu, Yi-Ping; An, Bing; Lai, Xiao-Wei

    2008-11-01

    The harm of heavy metals contained in electronic and electrical equipment (EEE) on environment is of high concern by human. Aiming to handle the great challenge of RoHS compliance, the determinations of trace or ultratrace chromium (Cr), cadmium (Cd), mercury (Hg) and lead (Pb) by inductively coupled plasma optical emission spectrometry (ICP-OES) was performed in the present paper, wherein, microwave extraction technology was used to prepare the sample solutions. In addition, the precision, recovery, repeatability and interference issues of this method were also discussed. The results exhibited that using the microwave extraction system to prepare samples is more quick, lossless, contamination-free in comparison with the conventional extraction methods such as dry ashing, wet-oven extraction etc. By analyzing the recoveries of these four heavy metals over different working time and wavelengths, the good recovery range between 85% and 115% showed that there was only tiny loss or contamination during the process of microwave extraction, sample introduction and ICP detection. Repeatability experiments proved that ICP plasma had a good stability during the working time and the matrix effect was small. Interference was a problem troublesome for atomic absorption spectrometry (AAS), however, the techniques of standard additions or inter-element correction (IEC) method can effectively eliminated the interferences of Ni, As, Fe etc. with the Cd determination. By employing the multi-wavelengths and two correction point methods, the issues of background curve sloping shift and spectra overlap were successfully overcome. Besides, for the determinations of trace heavy metal elements, the relative standard deviation (RSD) was less than 3% and the detection limits were less than 1 microg x L(-10 (3sigma, n = 5) for samples, standard solutions, and standard additions, which proved that ICP-OES has a good precision and high reliability. This provided a reliable technique support for electronic and electrical (EE) industries to comply with RoHS directive.

  9. Slurry micro-sampling technique for use in argon-helium microwave induced plasma optical emission spectrometry.

    PubMed

    Ślachciński, Mariusz

    2016-12-01

    The Flow Focusing Pneumatic Nebulizer (FFPN) working at low liquid flow rates was evaluated for the elemental analysis in slurried samples by argon-helium microwave induced plasma optical emission spectrometry (MIP-OES). The obtained results achieved were compared with commercially available V-groove Babington type nebulizer (VBPN). A univariate approach and the simplex optimization procedure were used to achieve optimized conditions and derive analytical figures of merit. Analytical performance of the micro nebulization system was characterized by a determination of the limits of detection (LODs), the precision (RSDs) and the wash-out times for Ba, Ca, Cd, Cu, Fe, Mg, Mn, Pb and Sr. The experimental concentration detection limits for simultaneous determination, calculated as the concentration giving a signal equal to three times of the standard deviation of the blank (LOD, 3σ blank criterion, peak height) were 0.9, 0.2, 0.3, 0.2, 0.3, 0.1, 0.2, 0.4, 0.4 and 0.3ngmL -1 for Ba, Ca, Cd, Cu, Fe, Mg, Mn, Pb and Sr, respectively. The method offers relatively good precision (RSD ranged from 5% to 8%) for micro-slurry sampling analysis. Analyses of the certified reference materials (NRCC DOLT-2, GBW 07302 and SRM 2710) were performed in order to determine the accuracy available with the presented nebulization systems. The measured contents of elements in the reference materials were in satisfactory agreement with the certified values. In addition, these elements were determined in two real samples. Slurry concentration up to 3% m/v (particles <20μm), prepared in 10% m/v HCl through the application of ultrasonic agitation, was used with calibration by the standard addition technique. An ultrasonic probe was used to homogenize the slurry in the polypropylene bottle just before its introduction into the nebulizer. The nebulizers exhibited no clogging problems. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Maternal blood contamination of collected cord blood can be identified using DNA methylation at three CpGs.

    PubMed

    Morin, Alexander M; Gatev, Evan; McEwen, Lisa M; MacIsaac, Julia L; Lin, David T S; Koen, Nastassja; Czamara, Darina; Räikkönen, Katri; Zar, Heather J; Koenen, Karestan; Stein, Dan J; Kobor, Michael S; Jones, Meaghan J

    2017-01-01

    Cord blood is a commonly used tissue in environmental, genetic, and epigenetic population studies due to its ready availability and potential to inform on a sensitive period of human development. However, the introduction of maternal blood during labor or cross-contamination during sample collection may complicate downstream analyses. After discovering maternal contamination of cord blood in a cohort study of 150 neonates using Illumina 450K DNA methylation (DNAm) data, we used a combination of linear regression and random forest machine learning to create a DNAm-based screening method. We identified a panel of DNAm sites that could discriminate between contaminated and non-contaminated samples, then designed pyrosequencing assays to pre-screen DNA prior to being assayed on an array. Maternal contamination of cord blood was initially identified by unusual X chromosome DNA methylation patterns in 17 males. We utilized our DNAm panel to detect contaminated male samples and a proportional amount of female samples in the same cohort. We validated our DNAm screening method on an additional 189 sample cohort using both pyrosequencing and DNAm arrays, as well as 9 publically available cord blood 450K data sets. The rate of contamination varied from 0 to 10% within these studies, likely related to collection specific methods. Maternal blood can contaminate cord blood during sample collection at appreciable levels across multiple studies. We have identified a panel of markers that can be used to identify this contamination, either post hoc after DNAm arrays have been completed, or in advance using a targeted technique like pyrosequencing.

  11. Improvements in the processing of large grain, bulk Y-Ba-Cu-O superconductors via the use of additional liquid phase

    NASA Astrophysics Data System (ADS)

    Congreve, Jasmin V. J.; Shi, Yunhua; Dennis, Anthony R.; Durrell, John H.; Cardwell, David A.

    2017-01-01

    A major limitation to the widespread application of Y-Ba-Cu-O (YBCO) bulk superconductors is the relative complexity and low yield of the top seeded melt growth (TSMG) process, by which these materials are commonly fabricated. It has been demonstrated in previous work on the recycling of samples in which the primary growth had failed, that the provision of an additional liquid-rich phase to replenish liquid lost during the failed growth process leads to the reliable growth of relatively high quality recycled samples. In this paper we describe the adaptation of the liquid phase enrichment technique to the primary TSMG fabrication process. We further describe the observed differences between the microstructure and superconducting properties of samples grown with additional liquid-rich phase and control samples grown using a conventional TSMG process. We observe that the introduction of the additional liquid-rich phase leads to the formation of a higher concentration of Y species at the growth front, which leads, in turn, to a more uniform composition at the growth front. Importantly, the increased uniformity at the growth front leads directly to an increased homogeneity in the distribution of the Y-211 inclusions in the superconducting Y-123 phase matrix and to a more uniform Y-123 phase itself. Overall, the provision of an additional liquid-rich phase improves significantly both the reliability of grain growth through the sample thickness and the magnitude and homogeneity of the superconducting properties of these samples compared to those fabricated by a conventional TSMG process.

  12. Design and development of a highly sensitive, field portable plasma source instrument for on-line liquid stream monitoring and real-time sample analysis

    NASA Astrophysics Data System (ADS)

    Duan, Yixiang; Su, Yongxuan; Jin, Zhe; Abeln, Stephen P.

    2000-03-01

    The development of a highly sensitive, field portable, low-powered instrument for on-site, real-time liquid waste stream monitoring is described in this article. A series of factors such as system sensitivity and portability, plasma source, sample introduction, desolvation system, power supply, and the instrument configuration, were carefully considered in the design of the portable instrument. A newly designed, miniature, modified microwave plasma source was selected as the emission source for spectroscopy measurement, and an integrated small spectrometer with a charge-coupled device detector was installed for signal processing and detection. An innovative beam collection system with optical fibers was designed and used for emission signal collection. Microwave plasma can be sustained with various gases at relatively low power, and it possesses high detection capabilities for both metal and nonmetal pollutants, making it desirable to use for on-site, real-time, liquid waste stream monitoring. An effective in situ sampling system was coupled with a high efficiency desolvation device for direct-sampling liquid samples into the plasma. A portable computer control system is used for data processing. The new, integrated instrument can be easily used for on-site, real-time monitoring in the field. The system possesses a series of advantages, including high sensitivity for metal and nonmetal elements; in situ sampling; compact structure; low cost; and ease of operation and handling. These advantages will significantly overcome the limitations of previous monitoring techniques and make great contributions to environmental restoration and monitoring.

  13. AGARD Flight Test Techniques Series. Volume 16. Introduction to Airborne Early Warning Radar Flight Test. (Introduction aux essais en vol des Radars Aeroportes d’Alerte Lointaine)

    DTIC Science & Technology

    1999-11-01

    Acknowledgements The authors would like to acknowledge several people who contributed directly or indirectly to this book. First, to Bruce Hislop and Larry...McGraw Hill Publishing Company, 1980 . 27. Smith, L. J., and Matthews, N. 0., Aircraft Flight Test Data Processing-A Review of the State of the Art...AGARDograph 160, Volume 12, 1980 . 28. Smith, Sidney L. and Mosier, Jane N., Guidelines for Designing User Interfaces to Computer Based Systems, MITRE

  14. A single frame: imaging live cells twenty-five years ago.

    PubMed

    Fink, Rachel

    2011-07-01

    In the mid-1980s live-cell imaging was changed by the introduction of video techniques, allowing new ways to collect and store data. The increased resolution obtained by manipulating video signals, the ability to use time-lapse videocassette recorders to study events that happen over long time intervals, and the introduction of fluorescent probes and sensitive video cameras opened research avenues previously unavailable. The author gives a personal account of this evolution, focusing on cell migration studies at the Marine Biological Laboratory 25 years ago. Copyright © 2011 Wiley-Liss, Inc.

  15. An Experimental Study of the Driving Mechanism and Control of the Unsteady Shock Induced Turbulent Separation in a Mach 5 Compression Corner Flow.

    DTIC Science & Technology

    1992-01-01

    vili Table of Contents Section Page List of Tables xiii List of Figures xiv Nomenclature xxii 1 Introduction 1 1.1 Motivation 1 1.2 Objective of...Introduction 1.1 Motivation The mid-1980’s saw a renewed interest in hypersonic flight. Motivated by the achievements of the American Space Transportation... measuments made downstrem of the compreson corner. 4.2.2 VITA Technique Another approach to event detection was applied to the fluctuating pitot

  16. Probability of introducing foot and mouth disease into the United States via live animal importation.

    PubMed

    Miller, G Y; Ming, J; Williams, I; Gorvett, R

    2012-12-01

    Foot and mouth disease (FMD) continues to be a disease of major concern for the United States Department of Agriculture (USDA) and livestock industries. Foot and mouth disease virus is a high-consequence pathogen for the United States (USA). Live animal trade is a major risk factor for introduction of FMD into a country. This research estimates the probability of FMD being introduced into the USA via the legal importation of livestock. This probability is calculated by considering the potential introduction of FMD from each country from which the USA imports live animals. The total probability of introduction into the USA of FMD from imported livestock is estimated to be 0.415% per year, which is equivalent to one introduction every 241 years. In addition, to provide a basis for evaluating the significance of risk management techniques and expenditures, the sensitivity of the above result to changes in various risk parameter assumptions is determined.

  17. Gibbon Aggression During Introductions: An International Survey.

    PubMed

    Harl, Heather; Stevens, Lisa; Margulis, Susan W; Petersen, Jay

    2016-01-01

    Little is known regarding the prevalence of aggression seen during introductions of captive gibbons (Hylobatidae). In this study, an online survey was developed to quantify and collect contextual details regarding the frequency and types of aggression seen during introductions of captive gibbons (Hylobatidae). Nineteen percent of institutions (17 institutions) reported observing aggression, and 6 of these institutions recorded multiple instances of aggression, though a vast majority of these cases resulted in mild injuries or none at all. The female was the primary aggressor in 23% of cases, the male was the primary aggressor in 58% of cases, and both were the primary aggressor in 1 case. Although these aggressive interactions were often not associated with a known cause, 27% of cases were associated with food displacement. In most cases, management changes, including trying new pairings, greatly reduced situational aggression, suggesting that individual personalities may play a factor in aggression. These data begin to explain the extent of aggression observed in captive gibbons; future studies will address possible correlations with aggression and introduction techniques.

  18. Introduction to Pharmaceutical Biotechnology, Volume 1; Basic techniques and concepts

    NASA Astrophysics Data System (ADS)

    Bhatia, Saurabh; Goli, Divakar

    2018-05-01

    Animal biotechnology is a broad field including polarities of fundamental and applied research, as well as DNA science, covering key topics of DNA studies and its recent applications. In Introduction to Pharmaceutical Biotechnology, DNA isolation procedures followed by molecular markers and screening methods of the genomic library are explained. Interesting areas like isolation, sequencing and synthesis of genes, with the broader coverage on synthesis of genes, are also described. The book begins with an introduction to biotechnology and its main branches, explaining both the basic science and the applications of biotechnology-derived pharmaceuticals, with special emphasis on their clinical use. It then moves on to historical development and scope of biotechnology with an overall review of early applications that scientists employed long before the field was defined.

  19. The Study of Algae

    ERIC Educational Resources Information Center

    Rushforth, Samuel R.

    1977-01-01

    Included in this introduction to the study of algae are drawings of commonly encountered freshwater algae, a summary of the importance of algae, descriptions of the seven major groups of algae, and techniques for collection and study of algae. (CS)

  20. A survey of mixed finite element methods

    NASA Technical Reports Server (NTRS)

    Brezzi, F.

    1987-01-01

    This paper is an introduction to and an overview of mixed finite element methods. It discusses the mixed formulation of certain basic problems in elasticity and hydrodynamics. It also discusses special techniques for solving the discrete problem.

  1. Automotive Manufacturing Processes. volume I - Overview

    DOT National Transportation Integrated Search

    1981-02-01

    Extensive material substitution and re-sizing of the domestic automotive fleet, as well as the introduction of new technologies, will require major changes in the techniques and equipment used in the various manufacturing processes employed in the pr...

  2. Automotive Manufacturing Processes. Volume I - Overview

    DOT National Transportation Integrated Search

    1981-02-01

    Extensive material substitution and re-sizing of the domestic automotive fleet, as well as the introduction of new technologies, will require major changes in the techniques and equipment used in the various manufacturing processes employed in the pr...

  3. Automobile Marketing Strategies, Pricing, and Product Planning

    DOT National Transportation Integrated Search

    1978-04-01

    The objective of the study was to determine the decision-making processes concerning major model year product introductions and alterations in the automotive industry as well as to investigate techniques of price positioning, product and image positi...

  4. Automobile Marketing Strategies, Pricing, and Product Planning

    DOT National Transportation Integrated Search

    1978-01-01

    The objective of the study was to determine the decision-making processes concerning major model year product introductions and alterations in the automotive industry as well as to investigate techniques of price positioning, product and image positi...

  5. Optimal Budget Allocation for Sample Average Approximation

    DTIC Science & Technology

    2011-06-01

    an optimization algorithm applied to the sample average problem. We examine the convergence rate of the estimator as the computing budget tends to...regime for the optimization algorithm . 1 Introduction Sample average approximation (SAA) is a frequently used approach to solving stochastic programs...appealing due to its simplicity and the fact that a large number of standard optimization algorithms are often available to optimize the resulting sample

  6. Development of an automated high-temperature valveless injection system for online gas chromatography

    DOE PAGES

    Kreisberg, N. M.; Worton, D. R.; Zhao, Y.; ...

    2014-12-12

    A reliable method of sample introduction is presented for online gas chromatography with a special application to in situ field portable atmospheric sampling instruments. A traditional multi-port valve is replaced with a valveless sample introduction interface that offers the advantage of long-term reliability and stable sample transfer efficiency. An engineering design model is presented and tested that allows customizing this pressure-switching-based device for other applications. Flow model accuracy is within measurement accuracy (1%) when parameters are tuned for an ambient-pressure detector and 15% accurate when applied to a vacuum-based detector. Laboratory comparisons made between the two methods of sample introductionmore » using a thermal desorption aerosol gas chromatograph (TAG) show that the new interface has approximately 3 times greater reproducibility maintained over the equivalent of a week of continuous sampling. Field performance results for two versions of the valveless interface used in the in situ instrument demonstrate typically less than 2% week -1 response trending and a zero failure rate during field deployments ranging up to 4 weeks of continuous sampling. Extension of the valveless interface to dual collection cells is presented with less than 3% cell-to-cell carryover.« less

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kreisberg, N. M.; Worton, D. R.; Zhao, Y.

    A reliable method of sample introduction is presented for online gas chromatography with a special application to in situ field portable atmospheric sampling instruments. A traditional multi-port valve is replaced with a valveless sample introduction interface that offers the advantage of long-term reliability and stable sample transfer efficiency. An engineering design model is presented and tested that allows customizing this pressure-switching-based device for other applications. Flow model accuracy is within measurement accuracy (1%) when parameters are tuned for an ambient-pressure detector and 15% accurate when applied to a vacuum-based detector. Laboratory comparisons made between the two methods of sample introductionmore » using a thermal desorption aerosol gas chromatograph (TAG) show that the new interface has approximately 3 times greater reproducibility maintained over the equivalent of a week of continuous sampling. Field performance results for two versions of the valveless interface used in the in situ instrument demonstrate typically less than 2% week -1 response trending and a zero failure rate during field deployments ranging up to 4 weeks of continuous sampling. Extension of the valveless interface to dual collection cells is presented with less than 3% cell-to-cell carryover.« less

  8. Mississippi Magic: Summer Library Program, 1999.

    ERIC Educational Resources Information Center

    Hudspeth, Jean; Shurden, Lynn Fletcher

    This manual for the 1999 Mississippi summer library program for preschool through elementary age children contains the following sections: (1) Introduction, including planning, promotional activities, sample radio spots and press releases, sample letters to parents, tips for including children with disabilities, a general bibliography, a…

  9. Particle-mesh techniques

    NASA Technical Reports Server (NTRS)

    Macneice, Peter

    1995-01-01

    This is an introduction to numerical Particle-Mesh techniques, which are commonly used to model plasmas, gravitational N-body systems, and both compressible and incompressible fluids. The theory behind this approach is presented, and its practical implementation, both for serial and parallel machines, is discussed. This document is based on a four-hour lecture course presented by the author at the NASA Summer School for High Performance Computational Physics, held at Goddard Space Flight Center.

  10. Stochastic Game Analysis and Latency Awareness for Self-Adaptation

    DTIC Science & Technology

    2014-01-01

    this paper, we introduce a formal analysis technique based on model checking of stochastic multiplayer games (SMGs) that enables us to quantify the...Additional Key Words and Phrases: Proactive adaptation, Stochastic multiplayer games , Latency 1. INTRODUCTION When planning how to adapt, self-adaptive...contribution of this paper is twofold: (1) A novel analysis technique based on model checking of stochastic multiplayer games (SMGs) that enables us to

  11. Next-Generation Sequencing in the Mycology Lab.

    PubMed

    Zoll, Jan; Snelders, Eveline; Verweij, Paul E; Melchers, Willem J G

    New state-of-the-art techniques in sequencing offer valuable tools in both detection of mycobiota and in understanding of the molecular mechanisms of resistance against antifungal compounds and virulence. Introduction of new sequencing platform with enhanced capacity and a reduction in costs for sequence analysis provides a potential powerful tool in mycological diagnosis and research. In this review, we summarize the applications of next-generation sequencing techniques in mycology.

  12. 78 FR 37837 - Agency Information Collection Activities: Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-24

    ... introduction of a new sample design is planned for the 2014 NSDUH. In addition to moving towards a proportional allocation by state, the 2014 sample design places more sample in the 26 or older age groups than in previous... National Drug Control Policy (ONDCP), Federal government agencies, and other organizations and researchers...

  13. National Sample Survey of Registered Nurses II. Status of Nurses: November 1980.

    ERIC Educational Resources Information Center

    Bentley, Barbara S.; And Others

    This report provides data describing the nursing population as determined by the second national sample survey of registered nurses. A brief introduction is followed by a chapter that presents an overview of the survey methodology, including details on the sampling design, the response rate, and the statistical reliability. Chapter 3 provides a…

  14. Comparative evaluation of workload estimation techniques in piloting tasks

    NASA Technical Reports Server (NTRS)

    Wierwille, W. W.

    1983-01-01

    Techniques to measure operator workload in a wide range of situations and tasks were examined. The sensitivity and intrusion of a wide variety of workload assessment techniques in simulated piloting tasks were investigated. Four different piloting tasks, psychomotor, perceptual, mediational, and communication aspects of piloting behavior were selected. Techniques to determine relative sensitivity and intrusion were applied. Sensitivity is the relative ability of a workload estimation technique to discriminate statistically significant differences in operator loading. High sensitivity requires discriminable changes in score means as a function of load level and low variation of the scores about the means. Intrusion is an undesirable change in the task for which workload is measured, resulting from the introduction of the workload estimation technique or apparatus.

  15. Photogrammetric techniques for aerospace applications

    NASA Astrophysics Data System (ADS)

    Liu, Tianshu; Burner, Alpheus W.; Jones, Thomas W.; Barrows, Danny A.

    2012-10-01

    Photogrammetric techniques have been used for measuring the important physical quantities in both ground and flight testing including aeroelastic deformation, attitude, position, shape and dynamics of objects such as wind tunnel models, flight vehicles, rotating blades and large space structures. The distinct advantage of photogrammetric measurement is that it is a non-contact, global measurement technique. Although the general principles of photogrammetry are well known particularly in topographic and aerial survey, photogrammetric techniques require special adaptation for aerospace applications. This review provides a comprehensive and systematic summary of photogrammetric techniques for aerospace applications based on diverse sources. It is useful mainly for aerospace engineers who want to use photogrammetric techniques, but it also gives a general introduction for photogrammetrists and computer vision scientists to new applications.

  16. Many-body problem

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parry, W.E.

    1973-01-01

    An introduction is given to techniques used in the many-body problem, and a reference book is given for those techniques. Sevcral different formulations of the techniques, and their interrelations, are discussed, to prepare the reader for the published literature. Examples are taken mostly from the physics of solids, fluids and plasmas. Second quantization, perturbation theory, Green functions and correlation functions, examples in the use of diagrammatic perturbation theory, the equation of motion method, magnetism (the drone-fermion representation), linear response and transport processes, niany- body systems at zero temperature, the variational principle and pair-wave approximation. (UK)

  17. In Vivo Methods for the Assessment of Topical Drug Bioavailability

    PubMed Central

    Herkenne, Christophe; Alberti, Ingo; Naik, Aarti; Kalia, Yogeshvar N.; Mathy, François-Xavier; Préat, Véronique

    2007-01-01

    This paper reviews some current methods for the in vivo assessment of local cutaneous bioavailability in humans after topical drug application. After an introduction discussing the importance of local drug bioavailability assessment and the limitations of model-based predictions, the focus turns to the relevance of experimental studies. The available techniques are then reviewed in detail, with particular emphasis on the tape stripping and microdialysis methodologies. Other less developed techniques, including the skin biopsy, suction blister, follicle removal and confocal Raman spectroscopy techniques are also described. PMID:17985216

  18. Finite element modeling of truss structures with frequency-dependent material damping

    NASA Technical Reports Server (NTRS)

    Lesieutre, George A.

    1991-01-01

    A physically motivated modelling technique for structural dynamic analysis that accommodates frequency dependent material damping was developed. Key features of the technique are the introduction of augmenting thermodynamic fields (AFT) to interact with the usual mechanical displacement field, and the treatment of the resulting coupled governing equations using finite element analysis methods. The AFT method is fully compatible with current structural finite element analysis techniques. The method is demonstrated in the dynamic analysis of a 10-bay planar truss structure, a structure representative of those contemplated for use in future space systems.

  19. A New Technique for Preserving the Form of Artificially Inflated Endophalli of Bees.

    PubMed

    Dutra, A L; Oliveira, R

    2017-04-01

    We present a simple technique for keeping the form of artificially expanded endophalli in bees (Hymenoptera). Endophalli were inflated using the introduction of low melting-point agarose from a syringe inserted in the anterior opening of the metasoma. Under refrigeration, the endophalli kept their expanded shape for up to three days allowing the description of structure, morphometric analyses, and examination of the external sculpturing of the cuticle under scanning electron microscope. The technique provides new possibilities for the study of functional morphology, sexual selection, and reconstruction of bee phylogeny.

  20. Infant rolling abilities--the same or different 20 years after the back to sleep campaign?

    PubMed

    Darrah, Johanna; Bartlett, Doreen J

    2013-05-01

    To compare the order and age of emergence of rolling prone to supine and supine to prone before the introduction of back to sleep guidelines and 20 years after their introduction. The original normative data for the Alberta Infant Motor Scale (AIMS) were collected just prior to the introduction of back to sleep guidelines in 1992. Currently these norms are being re-evaluated. Data of rolling patterns of infants 36 weeks of age or younger from the original sample (n=1114) and the contemporary sample (n=351) were evaluated to compare the sequence of appearance of prone to supine and supine to prone rolls (proportion of infants passing each roll) and the ages of emergence (estimated age when 50% of infants passed each roll). The sequence of emergence and estimated age of appearance of both rolling directions were similar between the two time periods. The introduction of the supine sleep position to reduce the prevalence of Sudden Infant Death Syndrome (SIDS) has not altered the timing or sequence of infant rolling abilities. This information is valuable to health care providers involved in the surveillance of infants' development. Original normative age estimates for these two motor abilities are still appropriate. Copyright © 2012 Elsevier Ltd. All rights reserved.

Top