Sample records for sample positioning system

  1. Automated high-throughput flow-through real-time diagnostic system

    DOEpatents

    Regan, John Frederick

    2012-10-30

    An automated real-time flow-through system capable of processing multiple samples in an asynchronous, simultaneous, and parallel fashion for nucleic acid extraction and purification, followed by assay assembly, genetic amplification, multiplex detection, analysis, and decontamination. The system is able to hold and access an unlimited number of fluorescent reagents that may be used to screen samples for the presence of specific sequences. The apparatus works by associating extracted and purified sample with a series of reagent plugs that have been formed in a flow channel and delivered to a flow-through real-time amplification detector that has a multiplicity of optical windows, to which the sample-reagent plugs are placed in an operative position. The diagnostic apparatus includes sample multi-position valves, a master sample multi-position valve, a master reagent multi-position valve, reagent multi-position valves, and an optical amplification/detection system.

  2. [Analysis of false-positive reaction for bacterial detection of blood samples with the automated microbial detection system BacT/ALERT 3D].

    PubMed

    Zhu, Li-Wei; Yang, Xue-Mei; Xu, Xiao-Qin; Xu, Jian; Lu, Huang-Jun; Yan, Li-Xing

    2008-10-01

    This study was aimed to analyze the results of false positive reaction in bacterial detection of blood samples with BacT/ALERT 3D system, to evaluate the specificity of this system, and to decrease the false positive reaction. Each reaction flasks in past five years were processed for bacteria isolation and identification. When the initial cultures were positive, the remaining samples and the corresponding units were recultured if still available. 11395 blood samples were detected. It is worthy of note that the incubator temperature should be stabilized, avoiding fluctuation; when the cultures were alarmed, the reaction flasks showed be kept some hours for further incubation so as to trace a sharply increasing signal to support the judgement of true bacterial growth. The results indicated that 122 samples (1.07%) wee positive at initial culture, out of them 107 samples (88.7%) were found bacterial, and 15 samples (12.3%) were found nothing. The detection curves of positive samples resulted from bacterial growth showed ascent. In conclusion, maintenance of temperature stability and avoidance of temperature fluctuation in incubator could decrease the occurrence of false-positive reaction in detection process. The reaction flasks with positive results at initial culture should be recultured, and whether existence of a sharply ascending logarilhimic growth phase in bacterial growth curve should be further detected, which are helpful to distinguish false-positive reactions from true positive, and thus increase the specificity of the BacT/ALERT system.

  3. Application of the BAX for screening/genus Listeria polymerase chain reaction system for monitoring Listeria species in cold-smoked fish and in the smoked fish processing environment.

    PubMed

    Norton, D M; McCamey, M; Boor, K J; Wiedmann, M

    2000-03-01

    The cold-smoked fish industry was used as a model for the development of a system for monitoring Listeria spp. in foods and in the food processing environment. A total of 214 samples including raw fish, fish during the cold-smoking process, finished product, and environmental samples were collected from three processing facilities over two visits to each facility. Samples were screened for Listeria spp. using the BAX for Screening/genus Listeria polymerase chain reaction system (PCR) and by culture. Listeria spp., confirmed by the API Listeria test strip or by a PCR assay targeting the L. monocytogenes hlyA gene, were isolated from a total of 89 (41.6%) samples. Of these, 80 samples also tested positive for Listeria spp. using the BAX system. Specifically, 42 (55.3%) environmental samples (n = 76), 11 (25.6%) raw materials samples (n = 43), 20 (35.1%) samples from fish in various stages of processing (n = 57), and 7 (18.4%) finished product samples (n = 38) tested positive for Listeria spp. using the BAX system. Five (4.0%) of the 125 culture-negative samples yielded BAX system-positive results. Listeria isolates from each of nine culture-positive/BAX system-negative samples yielded a positive reaction when tested in pure culture by the BAX system, suggesting that our false-negative results were likely due to the presence of low Listeria numbers in the initial enrichment as opposed to nonreacting isolates. The employment of alternative enrichment protocols, such as the two-step enrichment recommended by the manufacturer, may increase the sensitivity of the assay.

  4. Using the global positioning system to map disturbance patterns of forest harvesting machinery

    Treesearch

    T.P. McDonald; E.A. Carter; S.E. Taylor

    2002-01-01

    Abstract: A method was presented to transform sampled machine positional data obtained from a global positioning system (GPS) receiver into a two-dimensional raster map of number of passes as a function of location. The effect of three sources of error in the transformation process were investigated: path sampling rate (receiver sampling frequency);...

  5. Versatile, low-cost, computer-controlled, sample positioning system for vacuum applications

    NASA Technical Reports Server (NTRS)

    Vargas-Aburto, Carlos; Liff, Dale R.

    1991-01-01

    A versatile, low-cost, easy to implement, microprocessor-based motorized positioning system (MPS) suitable for accurate sample manipulation in a Second Ion Mass Spectrometry (SIMS) system, and for other ultra-high vacuum (UHV) applications was designed and built at NASA LeRC. The system can be operated manually or under computer control. In the latter case, local, as well as remote operation is possible via the IEEE-488 bus. The position of the sample can be controlled in three linear orthogonal and one angular coordinates.

  6. 40 CFR 141.405 - Reporting and recordkeeping for ground water systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... to the State within 30 days of the total coliform positive sample that it met the State criteria. (b... system(s) of total-coliform positive samples that are not invalidated under § 141.21(c). Documentation...

  7. 40 CFR 141.405 - Reporting and recordkeeping for ground water systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... to the State within 30 days of the total coliform positive sample that it met the State criteria. (b... system(s) of total-coliform positive samples that are not invalidated under § 141.21(c). Documentation...

  8. 40 CFR 141.405 - Reporting and recordkeeping for ground water systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... to the State within 30 days of the total coliform positive sample that it met the State criteria. (b... system(s) of total-coliform positive samples that are not invalidated under § 141.21(c). Documentation...

  9. An Efficient Referencing And Sample Positioning System To Investigate Heterogeneous Substances With Combined Microfocused Synchrotron X-ray Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spangenberg, Thomas; Goettlicher, Joerg; Steininger, Ralph

    2009-01-29

    A referencing and sample positioning system has been developed to transfer object positions measured with an offline microscope to a synchrotron experimental station. The accuracy should be sufficient to deal with heterogeneous samples on micrometer scale. Together with an online fluorescence mapping visualisation the optical alignment helps to optimize measuring procedures for combined microfocused X-ray techniques.

  10. 40 CFR 141.405 - Reporting and recordkeeping for ground water systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... to the State within 30 days of the total coliform positive sample that it met the State criteria. (b... system(s) of total coliform-positive samples that are not invalidated under § 141.21(c) until March 31...

  11. Method and system having ultrasonic sensor movable by translation device for ultrasonic profiling of weld samples

    DOEpatents

    Panyard, James; Potter, Timothy; Charron, William; Hopkins, Deborah; Reverdy, Frederic

    2010-04-06

    A system for ultrasonic profiling of a weld sample includes a carriage movable in opposite first and second directions. An ultrasonic sensor is coupled to the carriage to move over the sample as the carriage moves. An encoder determines the position of the carriage to determine the position of the sensor. A spring is connected at one end of the carriage. Upon the carriage being moved in the first direction toward the spring such that the carriage and the sensor are at a beginning position and the spring is compressed the spring decompresses to push the carriage back along the second direction to move the carriage and the sensor from the beginning position to an ending position. The encoder triggers the sensor to take the ultrasonic measurements of the sample when the sensor is at predetermined positions while the sensor moves over the sample between the beginning and positions.

  12. Sample positioning in microgravity

    NASA Technical Reports Server (NTRS)

    Sridharan, Govind (Inventor)

    1991-01-01

    Repulsion forces arising from laser beams are provided to produce mild positioning forces on a sample in microgravity vacuum environments. The system of the preferred embodiment positions samples using a plurality of pulsed lasers providing opposing repulsion forces. The lasers are positioned around the periphery of a confinement area and expanded to create a confinement zone. The grouped laser configuration, in coordination with position sensing devices, creates a feedback servo whereby stable position control of a sample within microgravity environment can be achieved.

  13. Sample positioning in microgravity

    NASA Technical Reports Server (NTRS)

    Sridharan, Govind (Inventor)

    1993-01-01

    Repulsion forces arising from laser beams are provided to produce mild positioning forces on a sample in microgravity vacuum environments. The system of the preferred embodiment positions samples using a plurality of pulsed lasers providing opposing repulsion forces. The lasers are positioned around the periphery of a confinement area and expanded to create a confinement zone. The grouped laser configuration, in coordination with position sensing devices, creates a feedback servo whereby stable position control of a sample within microgravity environment can be achieved.

  14. Development of a reverse transcription-loop-mediated isothermal amplification (RT-LAMP) system for a highly sensitive detection of enterovirus in the stool samples of acute flaccid paralysis cases.

    PubMed

    Arita, Minetaro; Ling, Hua; Yan, Dongmei; Nishimura, Yorihiro; Yoshida, Hiromu; Wakita, Takaji; Shimizu, Hiroyuki

    2009-12-16

    In the global eradication program for poliomyelitis, the laboratory diagnosis plays a critical role by isolating poliovirus (PV) from the stool samples of acute flaccid paralysis (AFP) cases. In this study, we developed a reverse transcription-loop-mediated isothermal amplification (RT-LAMP) system for a rapid and highly sensitive detection of enterovirus including PV to identify stool samples positive for enterovirus including PV. A primer set was designed for RT-LAMP to detect enterovirus preferably those with PV-like 5'NTRs of the viral genome. The sensitivity of RT-LAMP system was evaluated with prototype strains of enterovirus. Detection of enterovirus from stool extracts was examined by using RT-LAMP system. We detected at least 400 copies of the viral genomes of PV(Sabin) strains within 90 min by RT-LAMP with the primer set. This RT-LAMP system showed a preference for Human enterovirus species C (HEV-C) strains including PV, but exhibited less sensitivity to the prototype strains of HEV-A and HEV-B (detection limits of 7,400 to 28,000 copies). Stool extracts, from which PV, HEV-C, or HEV-A was isolated in the cell culture system, were mostly positive by RT-LAMP method (positive rates of 15/16 (= 94%), 13/14 (= 93%), and 4/4 (= 100%), respectively). The positive rate of this RT-LAMP system for stool extracts from which HEV-B was isolated was lower than that of HEV-C (positive rate of 11/21 (= 52%)). In the stool samples, which were negative for enterovirus isolation by the cell culture system, we found that two samples were positive for RT-LAMP (positive rates of 2/38 (= 5.3%)). In these samples, enterovirus 96 was identified by sequence analysis utilizing a seminested PCR system. RT-LAMP system developed in this study showed a high sensitivity comparable to that of the cell culture system for the detection of PV, HEV-A, and HEV-C, but less sensitivity to HEV-B. This RT-LAMP system would be useful for the direct detection of enterovirus from the stool extracts.

  15. System for precise position registration

    DOEpatents

    Sundelin, Ronald M.; Wang, Tong

    2005-11-22

    An apparatus for enabling accurate retaining of a precise position, such as for reacquisition of a microscopic spot or feature having a size of 0.1 mm or less, on broad-area surfaces after non-in situ processing. The apparatus includes a sample and sample holder. The sample holder includes a base and three support posts. Two of the support posts interact with a cylindrical hole and a U-groove in the sample to establish location of one point on the sample and a line through the sample. Simultaneous contact of the third support post with the surface of the sample defines a plane through the sample. All points of the sample are therefore uniquely defined by the sample and sample holder. The position registration system of the current invention provides accuracy, as measured in x, y repeatability, of at least 140 .mu.m.

  16. Detection of Shiga toxin-producing Escherichia coli (STEC) O157:H7, O26, O45, O103, O111, O121, and O145, and Salmonella in retail raw ground beef using the DuPont™ BAX® system.

    PubMed

    Wasilenko, Jamie L; Fratamico, Pina M; Sommers, Christopher; DeMarco, Daniel R; Varkey, Stephen; Rhoden, Kyle; Tice, George

    2014-01-01

    Shiga toxin-producing Escherichia coli (STEC) and Salmonella are food-borne pathogens commonly associated with beef, and reliable methods are needed to determine their prevalence in beef and to ensure food safety. Retail ground beef was tested for the presence of E. coli O157:H7, STEC serogroups O26, O45, O103, O111, O121, and O145, and Salmonella using the DuPont™ BAX® system method. Ground beef (325 g) samples were enriched in 1.5 L of TSB with 2 mg/L novobiocin at 42°C for 18 h, and then evaluated using the BAX® System real-time PCR assays for E. coli O157:H7 and STEC suite, and the BAX® System standard PCR assays for E. coli O157:H7 MP and Salmonella. Samples positive for STEC target genes by the BAX® System assays were subjected to immunomagnetic separation (IMS) and plating onto modified Rainbow Agar O157. Enrichments that were PCR positive for Salmonella were inoculated into RV broth, incubated for 18 h at 42°C, and then plated onto XLT-4 agar. Presumptive positive STEC and Salmonella colonies were confirmed using the BAX® System assays. Results of the BAX® System STEC assays showed 20/308 (6.5%) of samples positive for both the Shiga toxin (stx) and intimin (eae) genes; 4 (1.3%) for stx, eae, and O26; 1 (0.3%) for stx, eae, and O45; 3 (1%) for stx, eae, and O103; and 1 (0.3%) for stx, eae, and O145. There were also 3 samples positive for stx, eae, and more than one STEC serogroup. Three (1.0%) of the samples were positive using the BAX® System real-time E. coli O157:H7 assay, and 28 (9.1%) were positive using the BAX® System Salmonella assay. STEC O103 and E. coli O157:H7 were isolated from 2/6 and 2/3 PCR positive samples, respectively. Salmonella isolates were recovered and confirmed from 27 of the 28 Salmonella PCR positive samples, and a portion of the isolates were serotyped and antibiotic resistance profiles determined. Results demonstrate that the BAX® System assays are effective for detecting STEC and Salmonella in beef.

  17. Consensus for second-order multi-agent systems with position sampled data

    NASA Astrophysics Data System (ADS)

    Wang, Rusheng; Gao, Lixin; Chen, Wenhai; Dai, Dameng

    2016-10-01

    In this paper, the consensus problem with position sampled data for second-order multi-agent systems is investigated. The interaction topology among the agents is depicted by a directed graph. The full-order and reduced-order observers with position sampled data are proposed, by which two kinds of sampled data-based consensus protocols are constructed. With the provided sampled protocols, the consensus convergence analysis of a continuous-time multi-agent system is equivalently transformed into that of a discrete-time system. Then, by using matrix theory and a sampled control analysis method, some sufficient and necessary consensus conditions based on the coupling parameters, spectrum of the Laplacian matrix and sampling period are obtained. While the sampling period tends to zero, our established necessary and sufficient conditions are degenerated to the continuous-time protocol case, which are consistent with the existing result for the continuous-time case. Finally, the effectiveness of our established results is illustrated by a simple simulation example. Project supported by the Natural Science Foundation of Zhejiang Province, China (Grant No. LY13F030005) and the National Natural Science Foundation of China (Grant No. 61501331).

  18. Comparison of fecal pooling strategies for detection of Mycobacterium avium ssp. paratuberculosis in cattle.

    PubMed

    McKenna, S L B; Ritter, C; Dohoo, I; Keefe, G P; Barkema, H W

    2018-05-23

    In herds with typical moderate to low within-herd prevalence, testing for Mycobacterium avium ssp. paratuberculosis (MAP), the infectious agent of Johne's disease, will be more cost-effective if individual fecal samples are cultured in composite pools. However, sensitivity to classify a pool containing 1 or more positive individual samples as positive may depend on pool size and number of individual positive samples within a pool. Fecal samples collected from 994 dairy cows sampled at slaughter were cultured to detect MAP. Culturing was done both individually and as composite pooled samples using the TREK ESP Culture System II broth medium (Thermo Fisher Scientific, Trek Diagnostic Systems Inc., Cleveland, OH). Composite samples consisted of pools containing feces from 3, 5, 8, 10, or 15 cows. The number of individual fecal culture-positive cows within each pool ranged from 0 to 4. Culture of individual fecal samples detected MAP in 36 (3.6%) of the 994 cows. Individual samples that were detected within the first 50 d by TREK ESP Culture System II were more likely to lead to a positive pool result. In total, 840 pooled fecal samples were examined for presence of MAP, and of those, 272 pools actually contained feces from fecal culture-positive cows. The crude sensitivity (proportion of pools that contained at least 1 fecal-positive cow that tested positive) for pools of 3, 5, 8, 10, and 15 was 47, 67, 44, 59, and 39%, respectively. Across pools, an increase of the number of fecal culture-positive samples from 1 to 2 enhanced overall crude sensitivity from 44 to 71%. However, sensitivity did not further increase for pools with 3 or 4 fecal culture-positive samples (63 and 60%, respectively). Additionally, a simulation analysis assessing probability of pooled fecal samples being positive in herds of 50 and 100 cows was conducted. The simulation assumed that 1, 2, or 5 cows per herd were MAP fecal culture-positive and that pools of 5 and 10 were used. This low-prevalence herd simulation indicated that weighted mean herd probabilities of detecting a positive herd ranged between 52 and 99.3%, with the lowest probability for pools of 10 with 1 positive cow in the herd and the highest probability for pools of 5 with 5 positive cows in the herd. However, overall, pools of 5 and 10 had similar diagnostic capabilities, enabling cost savings by utilizing pools of 10. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  19. [Characteristics of blood type irregular antibodies in Han population of Chinese Sichuan area].

    PubMed

    Li, Cui-Ying; Li, Yun-Ming; Huang, Fei; Xiao, Jie; Xu, Hong

    2015-04-01

    To analyze the distribution of irregular antibody of red blood cells in Han population of Chinese Sichuan area, so as to provide valuable information for the safety of transfusion and decrease of immune hemolytic transfusion reaction. Blood samples from June 2006 to May 2013 were tested for irregular antibody screening and identification, calculating the composition rate, group characteristics and the positive detection rate of irregular antibody. A total of 36287 blood samples were tested, out of them 571 samples were the irregular antibody positive, the positive rate was 1.574%(571/36 287), specific alloantibodies were found in 312 samples, the positive rate was 0.860%(312/36287). And autoantibody was found in 259 samples, the positive rate was 0.714%(259/36 287). The specific alloantibodies ratio in Rh system was the highest, reaching to 73.72%(230/312) with the positive rate of 0.634%;36 cases in Lewis system, account for 11.54%(36/312) with the positive rate of 0.099%; 34 cases in MNS system account for 10.89%(34/312) with the positive rate of 0.094%; direct coomb test showed positive result in 284 samples, the rate was 0.78%. The detected rate of positive irregular antibody in female is obviously higher than that in male patients (P<0.001), and it is also higher in people with pregnancy or transfusion than that in those without it (P<0.05). The irregular antibody screening and identification are very important in blood transfusion, especially for female and people with transfusion or pregnant history.

  20. Development of a reverse transcription-loop-mediated isothermal amplification (RT-LAMP) system for a highly sensitive detection of enterovirus in the stool samples of acute flaccid paralysis cases

    PubMed Central

    2009-01-01

    Background In the global eradication program for poliomyelitis, the laboratory diagnosis plays a critical role by isolating poliovirus (PV) from the stool samples of acute flaccid paralysis (AFP) cases. In this study, we developed a reverse transcription-loop-mediated isothermal amplification (RT-LAMP) system for a rapid and highly sensitive detection of enterovirus including PV to identify stool samples positive for enterovirus including PV. Methods A primer set was designed for RT-LAMP to detect enterovirus preferably those with PV-like 5'NTRs of the viral genome. The sensitivity of RT-LAMP system was evaluated with prototype strains of enterovirus. Detection of enterovirus from stool extracts was examined by using RT-LAMP system. Results We detected at least 400 copies of the viral genomes of PV(Sabin) strains within 90 min by RT-LAMP with the primer set. This RT-LAMP system showed a preference for Human enterovirus species C (HEV-C) strains including PV, but exhibited less sensitivity to the prototype strains of HEV-A and HEV-B (detection limits of 7,400 to 28,000 copies). Stool extracts, from which PV, HEV-C, or HEV-A was isolated in the cell culture system, were mostly positive by RT-LAMP method (positive rates of 15/16 (= 94%), 13/14 (= 93%), and 4/4 (= 100%), respectively). The positive rate of this RT-LAMP system for stool extracts from which HEV-B was isolated was lower than that of HEV-C (positive rate of 11/21 (= 52%)). In the stool samples, which were negative for enterovirus isolation by the cell culture system, we found that two samples were positive for RT-LAMP (positive rates of 2/38 (= 5.3%)). In these samples, enterovirus 96 was identified by sequence analysis utilizing a seminested PCR system. Conclusions RT-LAMP system developed in this study showed a high sensitivity comparable to that of the cell culture system for the detection of PV, HEV-A, and HEV-C, but less sensitivity to HEV-B. This RT-LAMP system would be useful for the direct detection of enterovirus from the stool extracts. PMID:20015403

  1. Contained radiological analytical chemistry module

    DOEpatents

    Barney, David M.

    1989-01-01

    A system which provides analytical determination of a plurality of water chemistry parameters with respect to water samples subject to radiological contamination. The system includes a water sample analyzer disposed within a containment and comprising a sampling section for providing predetermined volumes of samples for analysis; a flow control section for controlling the flow through the system; and a gas analysis section for analyzing samples provided by the sampling system. The sampling section includes a controllable multiple port valve for, in one position, metering out sample of a predetermined volume and for, in a second position, delivering the material sample for analysis. The flow control section includes a regulator valve for reducing the pressure in a portion of the system to provide a low pressure region, and measurement devices located in the low pressure region for measuring sample parameters such as pH and conductivity, at low pressure. The gas analysis section which is of independent utility provides for isolating a small water sample and extracting the dissolved gases therefrom into a small expansion volume wherein the gas pressure and thermoconductivity of the extracted gas are measured.

  2. Contained radiological analytical chemistry module

    DOEpatents

    Barney, David M.

    1990-01-01

    A system which provides analytical determination of a plurality of water chemistry parameters with respect to water samples subject to radiological contamination. The system includes a water sample analyzer disposed within a containment and comprising a sampling section for providing predetermined volumes of samples for analysis; a flow control section for controlling the flow through the system; and a gas analysis section for analyzing samples provided by the sampling system. The sampling section includes a controllable multiple port valve for, in one position, metering out sample of a predetermined volume and for, in a second position, delivering the material sample for analysis. The flow control section includes a regulator valve for reducing the pressure in a portion of the system to provide a low pressure region, and measurement devices located in the low pressure region for measuring sample parameters such as pH and conductivity, at low pressure. The gas analysis section which is of independent utility provides for isolating a small water sample and extracting the dissolved gases therefrom into a small expansion volume wherein the gas pressure and thermoconductivity of the extracted gas are measured.

  3. Improvement of the efficient referencing and sample positioning system for micro focused synchrotron X-ray techniques

    NASA Astrophysics Data System (ADS)

    Spangenberg, T.; Göttlicher, J.; Steininger, R.

    2016-05-01

    An efficient referencing and sample positioning system is a basic tool for a micro focus beamline at a synchrotron. The seven years ago introduced command line based system was upgraded at SUL-X beamline at ANKA [1]. A new combination of current server client techniques offers direct control and facilitates unexperienced users the handling of this frequently used tool.

  4. Validation of the 3M molecular detection system for the detection of listeria in meat, seafood, dairy, and retail environments.

    PubMed

    Fortes, Esther D; David, John; Koeritzer, Bob; Wiedmann, Martin

    2013-05-01

    There is a continued need to develop improved rapid methods for detection of foodborne pathogens. The aim of this project was to evaluate the 3M Molecular Detection System (3M MDS), which uses isothermal DNA amplification, and the 3M Molecular Detection Assay Listeria using environmental samples obtained from retail delicatessens and meat, seafood, and dairy processing plants. Environmental sponge samples were tested for Listeria with the 3M MDS after 22 and 48 h of enrichment in 3M Modified Listeria Recovery Broth (3M mLRB); enrichments were also used for cultural detection of Listeria spp. Among 391 samples tested for Listeria, 74 were positive by both the 3M MDS and the cultural method, 310 were negative by both methods, 2 were positive by the 3M MDS and negative by the cultural method, and one sample was negative by the 3M MDS and positive by the cultural method. Four samples were removed from the sample set, prior to statistical analyses, due to potential cross-contamination during testing. Listeria isolates from positive samples represented L. monocytogenes, L. innocua, L. welshimeri, and L. seeligeri. Overall, the 3M MDS and culture-based detection after enrichment in 3M mLRB did not differ significantly (P < 0.05) with regard to the number of positive samples, when chi-square analyses were performed for (i) number of positive samples after 22 h, (ii) number of positive samples after 48 h, and (iii) number of positive samples after 22 and/or 48 h of enrichment in 3M mLRB. Among 288 sampling sites that were tested with duplicate sponges, 67 each tested positive with the 3M MDS and the traditional U.S. Food and Drug Administration Bacteriological Analytical Manual method, further supporting that the 3M MDS performs equivalently to traditional methods when used with environmental sponge samples.

  5. An in-house assay for BK polyomavirus quantification using the Abbott m2000 RealTime system.

    PubMed

    Muldrew, Kenneth L; Lovett, Jennie L

    2013-11-01

    BK polyomavirus (BKPyV) quantification is useful for monitoring renal transplant patient response to therapy. The Abbott m2000 RealTime System employed by some clinical laboratories to perform US Food and Drug Administration-approved assays can also be used to develop in-house assays such as the one presented here. This study aimed to validate an in-house quantitative real-time PCR assay targeting the BKPyV major capsid VP1 gene for assessment of viral load using the Abbott m2000 RealTime System. BKPyV load was measured in 95 urine and plasma samples previously tested for BKPyV by one of three laboratories (46 BKPyV-positive samples consisting of 35 plasma and 11 urine samples; 49 samples negative for BKPyV consisting of 47 plasma and two urine samples). Two additional plasma specimens from the College of American Pathologists proficiency testing survey were also analysed. Precision studies were performed by diluting a high-viral-titre patient sample into BKPyV-negative pooled plasma to create high-positive (6.16 log10 copies ml(-1)) and low-positive (3.16 log10 copies ml(-1)) samples. For precision studies of inter-assay variability, a high-positive (7.0 log10 copies ml(-1)) and a low-positive (3.0 log10 copies ml(-1)) sample were measured in 20 separate runs. The assay's limit of quantification and limit of detection were 2.70 and 2.25 log10 copies ml(-1), respectively. The assay was linear from 2.70 to 9.26 log10 copies ml(-1). Of the 48 known positives, 43 were detected as positive, with three reported by the reference laboratory as values lower than the limit of detection. Two known positives at 3.27 and 3.80 log10 copies ml(-1) tested negative by the m2000 BKPyV assay. Of the 49 known negative samples, 48 were negative by the m2000 BKPyV load assay, with one sample confirmed positive by a reference laboratory. Qualitative analysis prior to discrepancy testing demonstrated a sensitivity of 89.58 % and a specificity of 97.96 %. Precision studies demonstrated inter-assay coefficients of variation of 0.63 % (high positive) and 4.38 % (low positive). Genotyping was performed on 22 patient samples, of which 21 (95.45 %) were type I and one (4.55 %) was type II. In conclusion, the m2000 BKPyV viral load assay sensitivity, specificity, linear range, precision and cost effectiveness make it an attractive methodology for clinical laboratories using the Abbott m2000 RealTime System.

  6. [Comparison of two different real-time PCR systems in postmortem diagnosis of tuberculosis in paraffin-embedded tissues].

    PubMed

    Yağmur, Gülhan; Albayrak, Nurhan; Daş, Taner; Yıldırım, Muzaffer; Ozgün, Ayşe; Büyük, Yalçın

    2014-10-01

    Tuberculosis (TB) is one of those infections with high morbidity and mortality in all around the world. Hundreds of people died from this disease without diagnosed or due to resistant strains in Turkey. Therefore, it is important to identify postmortem cases who have died from tuberculosis. Molecular methods have been widely used as well as conventional methods in the diagnosis of tuberculosis. The aim of this study was to compare the two different real-time polymerase chain reaction (Rt-PCR) system in the postmortem diagnosis of Mycobacterium tuberculosis infections in paraffin-embedded tissues. A total of 40 paraffin-embedded tissue samples [lung (n= 35), brain (n= 2), heart (n= 2), lymph node (n= 1)] in which histopathologic findings consistent with TB (necrotizing granulomatous inflammation, gelatinous caseous pneumonia, necrotic fibrous nodul) obtained from 37 autopsy cases (31 male, 6 female; age range: 25-85 yrs) were included in the study. Paraffin-embedded tissues were deparafinized with xylene and ethyl alcohol and then DNA isolation was done with QIAsymphony DSP Virus/Pathogen Midi kit in the QIAsymphony device. DNA amplification process was performed by Rt-PCR using the kit Artus® M. tuberculosis RG-PCR in the Rotor-Gene® Q device (Qiagen, Germany). Likewise, after deparafinization process, samples placed in the cartridge and isolation and Rt-PCR was performed by Xpert® MTB/RIF (Cepheid, USA) system, simultaneosly. Seventeen and 20 out of the 40 paraffin-embedded tissues yielded positive results with Qiagen and Xpert system, respectively. M.tuberculosis DNA was found positive in 13 (32.5%) and negative in 16 (40%) of the samples by both of the systems, exhibiting 72.5% (29/40) of concordance. On the other hand, seven (17.5%) samples that were positive with Xpert system yielded negative result with the Qiagen, while four (10%) samples that were positive with Qiagen yielded negative result with the Xpert system. Of the 20 positive cases detected with Xpert MTB/RIF system, 15 were found rifampicin-susceptible, and three were rifampicin-resistant. In two samples in which M. tuberculosis DNA was low positive, rifampicin resistance could not be detected. The identification of M.tuberculosis infections in postmortem cases will contribute epidemiological data in Turkey. In these cases, effective sampling and diagnosing of M.tuberculosis infections by acid-fast stain and culture methods are crucial. However, in cases without microbiological sampling the detection of M.tuberculosis DNA in paraffin-embedded tissues with PCR, although there are differences between PCR systems has diagnostic value. In conclusion, our data indicated that Xpert MTB/RIF system is more favourable to detect M.tuberculosis DNA in paraffin-embedded tissues, with the advantages of determination of rifampicin resistance, and detection of more positive results within a shorter time.

  7. Detection of Listeria monocytogenes in pork and beef using the VIDAS® LMO2 automated enzyme linked immunoassay method.

    PubMed

    Meyer, Cornelia; Fredriksson-Ahomaa, Maria; Sperner, Brigitte; Märtlbauer, Erwin

    2011-07-01

    Listeria (L.) monocytogenes, a foodborne pathogen, is known to be a possible contaminant of foods during production and processing. Samples (n=985) of raw meat and by-products obtained from beef and pork were first screened by the VIDAS system for the presence of Listeria spp., followed by testing for the presence of L. monocytogenes. Positive L. monocytogenes results were confirmed by plating on selective agars: 14% of the samples were positive for Listeria and 4% tested positive for L. monocytogenes, of which 3% were confirmed on selective agars. In by-products (17%) the contamination with listeriae was higher than in meat cuts (10%). Only samples strongly positive for Listeria spp. by VIDAS were positive for L. monocytogenes. Overall, the prevalence of L. monocytogenes in beef and pork samples was rather low in comparison to most previous studies. The VIDAS system was shown to be a suitable method for screening out Listeria-negative samples; the main advantage being a markedly reduced assay time. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. A THz Tomography System for Arbitrarily Shaped Samples

    NASA Astrophysics Data System (ADS)

    Stübling, E.; Bauckhage, Y.; Jelli, E.; Fischer, B.; Globisch, B.; Schell, M.; Heinrich, A.; Balzer, J. C.; Koch, M.

    2017-10-01

    We combine a THz time-domain spectroscopy system with a robotic arm. With this scheme, the THz emitter and receiver can be positioned perpendicular and at defined distance to the sample surface. Our system allows the acquisition of reflection THz tomographic images of samples with an arbitrarily shaped surface.

  9. A modular and compact portable mini-endstation for high-precision, high-speed fixed target serial crystallography at FEL and synchrotron sources

    DOE PAGES

    Sherrell, Darren A.; Foster, Andrew J.; Hudson, Lee; ...

    2015-01-01

    The design and implementation of a compact and portable sample alignment system suitable for use at both synchrotron and free-electron laser (FEL) sources and its performance are described. The system provides the ability to quickly and reliably deliver large numbers of samples using the minimum amount of sample possible, through positioning of fixed target arrays into the X-ray beam. The combination of high-precision stages, high-quality sample viewing, a fast controller and a software layer overcome many of the challenges associated with sample alignment. A straightforward interface that minimizes setup and sample changeover time as well as simplifying communication with themore » stages during the experiment is also described, together with an intuitive naming convention for defining, tracking and locating sample positions. Lastly, the setup allows the precise delivery of samples in predefined locations to a specific position in space and time, reliably and simply.« less

  10. Legionella species colonization of water distribution systems, pools and air conditioning systems in cruise ships and ferries

    PubMed Central

    Goutziana, Georgia; Mouchtouri, Varvara A; Karanika, Maria; Kavagias, Antonios; Stathakis, Nikolaos E; Gourgoulianis, Kostantinos; Kremastinou, Jenny; Hadjichristodoulou, Christos

    2008-01-01

    Background Legionnaires' disease continues to be a public health concern in passenger ships. This study was scheduled in order to investigate Legionella spp. colonization of water distribution systems (WDS), recreational pools, and air-conditioning systems on board ferries and cruise ships in an attempt to identify risk factors for Legionella spp. colonization associated with ship water systems and water characteristics. Methods Water systems of 21 ferries and 10 cruise ships including WDS, air conditioning systems and pools were investigated for the presence of Legionella spp. Results The 133 samples collected from the 10 cruise ships WDS, air conditioning systems and pools were negative for Legionella spp. Of the 21 ferries WDS examined, 14 (66.7%) were legionellae-positive. A total of 276 samples were collected from WDS and air conditioning systems. Legionella spp. was isolated from 37.8% of the hot water samples and 17.5% of the cold water samples. Of the total 96 positive isolates, 87 (90.6%) were L. pneumophila. Legionella spp. colonization was positively associated with ship age. The temperature of the hot water samples was negatively associated with colonization of L. pneumophila serogroup (sg) 1 and that of L. pneumophila sg 2 to 14. Increases in pH ≥7.8 and total plate count ≥400 CFU/L, correlated positively with the counts of L. pneumophila sg 2 to 14 and Legionella spp. respectively. Free chlorine of ≥0.2 mg/L inhibited colonization of Legionella spp. Conclusion WDS of ferries can be heavily colonized by Legionella spp. and may present a risk of Legionnaires' disease for passengers and crew members. Guidelines and advising of Legionnaires' disease prevention regarding ferries are needed, in particular for operators and crew members. PMID:19025638

  11. Legionella species colonization of water distribution systems, pools and air conditioning systems in cruise ships and ferries.

    PubMed

    Goutziana, Georgia; Mouchtouri, Varvara A; Karanika, Maria; Kavagias, Antonios; Stathakis, Nikolaos E; Gourgoulianis, Kostantinos; Kremastinou, Jenny; Hadjichristodoulou, Christos

    2008-11-24

    Legionnaires' disease continues to be a public health concern in passenger ships. This study was scheduled in order to investigate Legionella spp. colonization of water distribution systems (WDS), recreational pools, and air-conditioning systems on board ferries and cruise ships in an attempt to identify risk factors for Legionella spp. colonization associated with ship water systems and water characteristics. Water systems of 21 ferries and 10 cruise ships including WDS, air conditioning systems and pools were investigated for the presence of Legionella spp. The 133 samples collected from the 10 cruise ships WDS, air conditioning systems and pools were negative for Legionella spp. Of the 21 ferries WDS examined, 14 (66.7%) were legionellae-positive. A total of 276 samples were collected from WDS and air conditioning systems. Legionella spp. was isolated from 37.8% of the hot water samples and 17.5% of the cold water samples. Of the total 96 positive isolates, 87 (90.6%) were L. pneumophila. Legionella spp. colonization was positively associated with ship age. The temperature of the hot water samples was negatively associated with colonization of L. pneumophila serogroup (sg) 1 and that of L. pneumophila sg 2 to 14. Increases in pH >/=7.8 and total plate count > or =400 CFU/L, correlated positively with the counts of L. pneumophila sg 2 to 14 and Legionella spp. respectively. Free chlorine of > or =0.2 mg/L inhibited colonization of Legionella spp. WDS of ferries can be heavily colonized by Legionella spp. and may present a risk of Legionnaires' disease for passengers and crew members. Guidelines and advising of Legionnaires' disease prevention regarding ferries are needed, in particular for operators and crew members.

  12. Comparison of Clark's presence-absence test and the membrane filter method for coliform detection in potable water samples.

    PubMed Central

    Pipes, W O; Minnigh, H A; Moyer, B; Troy, M A

    1986-01-01

    A total of 2,601 water samples from six different water systems were tested for coliform bacteria by Clark's presence-absence (P-A) test and by the membrane filter (MF) method. There was no significant difference in the fraction of samples positive for coliform bacteria for any of the systems tested. It was concluded that the two tests are equivalent for monitoring purposes. However, 152 samples were positive for coliform bacteria by the MF method but negative by the P-A test, and 132 samples were positive by the P-A test but negative by the MF method. Many of these differences for individual samples can be explained by random dispersion of bacteria in subsamples when the coliform density is low. However, 15 samples had MF counts greater than 3 and gave negative P-A results. The only apparent explanation for most of these results is that coliform bacteria were present in the P-A test bottles but did not produce acid and gas. Two other studies have reported more samples positive by Clark's P-A test than by the MF method. PMID:3532953

  13. Sample introduction system for a flow cytometer

    DOEpatents

    Van den Engh, Ger

    1997-01-01

    A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning, HPLC tubing and fittings may be used in a manner which facilitates removing of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it.

  14. Sample introduction system for a flow cytometer

    DOEpatents

    Engh, G. van den

    1997-02-11

    A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning, HPLC tubing and fittings may be used in a manner which facilitates removing of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it. 3 figs.

  15. Evaluation of the HB&L System for the Microbiological Screening of Storage Medium for Organ-Cultured Corneas.

    PubMed

    Camposampiero, D; Grandesso, S; Zanetti, E; Mazzucato, S; Solinas, M; Parekh, M; Frigo, A C; Gion, M; Ponzin, D

    2013-01-01

    Aims. To compare HB&L and BACTEC systems for detecting the microorganisms contaminating the corneal storage liquid preserved at 31°C. Methods. Human donor corneas were stored at 4°C followed by preservation at 31°C. Samples of the storage medium were inoculated in BACTEC Peds Plus/F (aerobic microorganisms), BACTEC Plus Anaerobic/F (anaerobic microorganisms), and HB&L bottles. The tests were performed (a) after six days of storage, (b) end of storage, and (c) after 24 hours of preservation in deturgescent liquid sequentially. 10,655 storage and deturgescent media samples were subjected to microbiological control using BACTEC (6-day incubation) and HB&L (24-hour incubation) systems simultaneously. BACTEC positive/negative refers to both/either aerobic and anaerobic positives/negatives, whereas HB&L can only detect the aerobic microbes, and therefore the positives/negatives depend on the presence/absence of aerobic microorganisms. Results. 147 (1.38%) samples were identified positive with at least one of the two methods. 127 samples (134 identified microorganisms) were positive with both HB&L and BACTEC. 14 HB&L+/BACTEC- and 6 BACTEC+/HB&L- were identified. Sensitivity (95.5%), specificity (99.8%), and positive (90.1%) and negative predictive values (99.9%) were high with HB&L considering a 3.5% annual contamination rate. Conclusion. HB&L is a rapid system for detecting microorganisms in corneal storage medium in addition to the existing methods.

  16. Microbial ecology measurement system

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The sensitivity and potential rapidity of the PIA test that was demonstrated during the feasibility study warranted continuing the effort to examine the possibility of adapting this test to an automated procedure that could be used during manned missions. The effort during this program has optimized the test conditions for two important respiratory pathogens, influenza virus and Mycoplasma pneumoniae, developed a laboratory model automated detection system, and investigated a group antigen concept for virus detection. Preliminary tests on the handling of oropharygeal clinical samples for PIA testing were performed using the adenovirus system. The results obtained indicated that the PIA signal is reduced in positive samples and is increased in negative samples. Treatment with cysteine appeared to reduce nonspecific agglutination in negative samples but did not maintain the signal in positive samples.

  17. Geographical Information Systems (GIS) Mapping of Environmental Samples across College Campuses

    ERIC Educational Resources Information Center

    Purvis-Roberts, Kathleen L.; Moeur, Harriet P.; Zanella, Andrew

    2007-01-01

    In this laboratory experiment, students take environmental samples at various locations around the college campuses, take geospatial coordinates with a global position systems (GPS) unit, and map their results on a geo-referenced campus map with geographical information systems (GIS) software. Nitrogen dioxide air pollution sampling is used as an…

  18. Automation system for measurement of gamma-ray spectra of induced activity for multi-element high volume neutron activation analysis at the reactor IBR-2 of Frank Laboratory of Neutron Physics at the joint institute for nuclear research

    NASA Astrophysics Data System (ADS)

    Pavlov, S. S.; Dmitriev, A. Yu.; Chepurchenko, I. A.; Frontasyeva, M. V.

    2014-11-01

    The automation system for measurement of induced activity of gamma-ray spectra for multi-element high volume neutron activation analysis (NAA) was designed, developed and implemented at the reactor IBR-2 at the Frank Laboratory of Neutron Physics. The system consists of three devices of automatic sample changers for three Canberra HPGe detector-based gamma spectrometry systems. Each sample changer consists of two-axis of linear positioning module M202A by DriveSet company and disk with 45 slots for containers with samples. Control of automatic sample changer is performed by the Xemo S360U controller by Systec company. Positioning accuracy can reach 0.1 mm. Special software performs automatic changing of samples and measurement of gamma spectra at constant interaction with the NAA database.

  19. Bead-based microfluidic immunoassay for diagnosis of Johne's disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wadhwa, Ashutosh; Foote, Robert; Shaw, Robert W

    2012-01-01

    Microfluidics technology offers a platform for development of point-of-care diagnostic devices for various infectious diseases. In this study, we examined whether serodiagnosis of Johne s disease (JD) can be conducted in a bead-based microfluidic assay system. Magnetic micro-beads were coated with antigens of the causative agent of JD, Mycobacterium avium subsp. paratuberculosis. The antigen-coated beads were incubated with serum samples of JD-positive or negative serum samples and then with a fluorescently-labeled secondary antibody (SAB). To confirm binding of serum antibodies to the antigen, the beads were subjected to flow cytometric analysis. Different conditions (dilutions of serum and SAB, types ofmore » SAB, and types of magnetic beads) were optimized for a great degree of differentiation between the JD-negative and JD-positive samples. Using the optimized conditions, we tested a well-classified set of 155 serum samples from JD negative and JD-positive cattle by using the bead-based flow cytometric assay. Of 105 JD-positive samples, 63 samples (60%) showed higher antibody binding levels than a cut-off value determined by using antibody binding levels of JD-negative samples. In contrast, only 43-49 JD-positive samples showed higher antibody binding levels than the cut-off value when the samples were tested by commercially-available immunoassays. Microfluidic assays were performed by magnetically immobilizing a number of beads within a microchannel of a glass microchip and detecting antibody on the collected beads by laser-induced fluorescence. Antigen-coated magnetic beads treated with bovine serum sample and fluorescently-labeled SAB were loaded into a microchannel to measure the fluorescence (reflecting level of antibody binding) on the beads in the microfluidic system. When the results of five bovine serum samples obtained with the system were compared to those obtained with the flow cytometer, a high level of correlation (linear regression, r2 = 0.994) was observed. In a further experiment, we magnetically immobilized antigen-coated beads in a microchannel, reacted the beads with serum and SAB in the channel, and detected antibody binding to the beads in the microfluidic system. A strong antibody binding in JD-positive serum was detected, whereas there was only negligible binding in negative control experiments. Our data suggest that the bead-based microfluidic system may form a basis for development of an on-site serodiagnosis of JD. Key Words: Mycobacterium avium ssp. paratuberculosis, Johne s disease, microfluidics, lab-on-a-chip.« less

  20. Quality of different in-clinic test systems for feline immunodeficiency virus and feline leukaemia virus infection.

    PubMed

    Hartmann, Katrin; Griessmayr, Pascale; Schulz, Bianka; Greene, Craig E; Vidyashankar, Anand N; Jarrett, Os; Egberink, Herman F

    2007-12-01

    Many new diagnostic in-house tests for identification of feline immunodeficiency virus (FIV) and feline leukaemia virus (FeLV) infection have been licensed for use in veterinary practice, and the question of the relative merits of these kits has prompted comparative studies. This study was designed to define the strengths and weaknesses of seven FIV and eight FeLV tests that are commercially available. In this study, 536 serum samples from randomly selected cats were tested. Those samples reacting FIV-positive in at least one of the tests were confirmed by Western blot, and those reacting FeLV-positive were confirmed by virus isolation. In addition, a random selection of samples testing negative in all test systems was re-tested by Western blot (100 samples) and by virus isolation (81 samples). Specificity, sensitivity, positive and negative predictive values of each test and the quality of the results were compared.

  1. Floating Ultrasonic Transducer Inspection System and Method for Nondestructive Evaluation

    NASA Technical Reports Server (NTRS)

    Johnston, Patrick H. (Inventor); Zalameda, Joseph N. (Inventor)

    2016-01-01

    A method for inspecting a structural sample using ultrasonic energy includes positioning an ultrasonic transducer adjacent to a surface of the sample, and then transmitting ultrasonic energy into the sample. Force pulses are applied to the transducer concurrently with transmission of the ultrasonic energy. A host machine processes ultrasonic return pulses from an ultrasonic pulser/receiver to quantify attenuation of the ultrasonic energy within the sample. The host machine detects a defect in the sample using the quantified level of attenuation. The method may include positioning a dry couplant between an ultrasonic transducer and the surface. A system includes an actuator, an ultrasonic transducer, a dry couplant between the transducer the sample, a scanning device that moves the actuator and transducer, and a measurement system having a pulsed actuator power supply, an ultrasonic pulser/receiver, and a host machine that executes the above method.

  2. Spatially resolved imaging of opto-electrical property variations

    DOEpatents

    Nikiforov, Maxim; Darling, Seth B; Suzer, Ozgun; Guest, Jeffrey; Roelofs, Andreas

    2014-09-16

    Systems and methods for opto electric properties are provided. A light source illuminates a sample. A reference detector senses light from the light source. A sample detector receives light from the sample. A positioning fixture allows for relative positioning of the sample or the light source with respect to each other. An electrical signal device measures the electrical properties of the sample. The reference detector, sample detector and electrical signal device provide information that may be processed to determine opto-electric properties of the same.

  3. System and method for acquisition management of subject position information

    DOEpatents

    Carrender, Curt

    2005-12-13

    A system and method for acquisition management of subject position information that utilizes radio frequency identification (RF ID) to store position information in position tags. Tag programmers receive position information from external positioning systems, such as the Global Positioning System (GPS), from manual inputs, such as keypads, or other tag programmers. The tag programmers program each position tag with the received position information. Both the tag programmers and the position tags can be portable or fixed. Implementations include portable tag programmers and fixed position tags for subject position guidance, and portable tag programmers for collection sample labeling. Other implementations include fixed tag programmers and portable position tags for subject route recordation. Position tags can contain other associated information such as destination address of an affixed subject for subject routing.

  4. System and method for acquisition management of subject position information

    DOEpatents

    Carrender, Curt [Morgan Hill, CA

    2007-01-23

    A system and method for acquisition management of subject position information that utilizes radio frequency identification (RF ID) to store position information in position tags. Tag programmers receive position information from external positioning systems, such as the Global Positioning System (GPS), from manual inputs, such as keypads, or other tag programmers. The tag programmers program each position tag with the received position information. Both the tag programmers and the position tags can be portable or fixed. Implementations include portable tag programmers and fixed position tags for subject position guidance, and portable tag programmers for collection sample labeling. Other implementations include fixed tag programmers and portable position tags for subject route recordation. Position tags can contain other associated information such as destination address of an affixed subject for subject routing.

  5. Detection and identification of enteroviruses from various drinking water sources in Taiwan

    NASA Astrophysics Data System (ADS)

    Hsu, Bing-Mu; Chen, Chien-Hsien; Wan, Min-Tao; Chang, Po-Jen; Fan, Cheng-Wei

    2009-02-01

    SummaryTwenty-three water samples, including seventeen from surface water reservoirs, three from the raw water of groundwater treatment plants, and three from small water systems, were collected in Taiwan and investigated for the presence of, as well as the species of enteroviruses. RT-PCR was used for the detection of enteroviruses. Results revealed that 23.5% of raw water samples from reservoirs were positive for enteroviruses. In addition, one of the three groundwater samples and two of the three small system water samples were positive for enteroviruses. Water samples that were positive for enteroviruses subsequently were evaluated by real-time PCR. The results indicated that enterovirus concentration in groundwater was lower than that in samples obtained from surface water sources. Enteroviruses were identified by nucleic acid sequencing in the 5'-untranslated regions. Three clusters of enteroviruses were identified as coxsackievirus A2, coxsackievirus A6, and enterovirus 71. The presence of enteroviruses indicates the possibility of waterborne transmission of enteroviruses in Taiwan, if water is not adequately treated.

  6. The cobas p 630 instrument: a dedicated pre-analytic solution to optimize COBAS® AmpliPrep/COBAS® TaqMan® system workflow and turn-around-time.

    PubMed

    Vallefuoco, L; Sorrentino, R; Spalletti Cernia, D; Colucci, G; Portella, G

    2012-12-01

    The cobas p 630, a fully automated pre-analytical instrument for primary tube handling recently introduced to complete the Cobas(®) TaqMan systems portfolio, was evaluated in conjunction with: the COBAS(®) AmpliPrep/COBAS(®) TaqMan HBV Test, v2.0, COBAS(®) AmpliPrep/COBAS(®) TaqMan HCV Test, v1.0 and COBAS(®) AmpliPrep/COBAS(®) TaqMan HIV Test, v2.0. The instrument performance in transferring samples from primary to secondary tubes, its impact in improving COBAS(®) AmpliPrep/COBAS(®) TaqMan workflow and hands-on reduction and the risk of possible cross-contamination were assessed. Samples from 42 HBsAg positive, 42 HCV and 42 HIV antibody (Ab) positive patients as well as 21 healthy blood donors were processed with or without automated primary tubes. HIV, HCV and HBsAg positive samples showed a correlation index of 0.999, 0.987 and of 0.994, respectively. To assess for cross-contamination, high titer HBV DNA positive samples, HCV RNA and HIV RNA positive samples were distributed in the cobas p 630 in alternate tube positions, adjacent to negative control samples within the same rack. None of the healthy donor samples showed any reactivity. Based on these results, the cobas p 630 can improve workflow and sample tracing in laboratories performing molecular tests, and reduce turnaround time, errors, and risks. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Characterizing the rapid spread of porcine epidemic diarrhea virus (PEDV) through an animal food manufacturing facility.

    PubMed

    Schumacher, Loni L; Huss, Anne R; Cochrane, Roger A; Stark, Charles R; Woodworth, Jason C; Bai, Jianfa; Poulsen, Elizabeth G; Chen, Qi; Main, Rodger G; Zhang, Jianqiang; Gauger, Phillip C; Ramirez, Alejandro; Derscheid, Rachel J; Magstadt, Drew M; Dritz, Steve S; Jones, Cassandra K

    2017-01-01

    New regulatory and consumer demands highlight the importance of animal feed as a part of our national food safety system. Porcine epidemic diarrhea virus (PEDV) is the first viral pathogen confirmed to be widely transmissible in animal food. Because the potential for viral contamination in animal food is not well characterized, the objectives of this study were to 1) observe the magnitude of virus contamination in an animal food manufacturing facility, and 2) investigate a proposed method, feed sequencing, to decrease virus decontamination on animal food-contact surfaces. A U.S. virulent PEDV isolate was used to inoculate 50 kg swine feed, which was mixed, conveyed, and discharged into bags using pilot-scale feed manufacturing equipment. Surfaces were swabbed and analyzed for the presence of PEDV RNA by quantitative real-time polymerase chain reaction (qPCR). Environmental swabs indicated complete contamination of animal food-contact surfaces (0/40 vs. 48/48, positive baseline samples/total baseline samples, positive subsequent samples/total subsequent samples, respectively; P < 0.05) and near complete contamination of non-animal food-contact surfaces (0/24 vs. 16/18, positive baseline samples/total baseline samples, positive subsequent samples/total subsequent samples, respectively; P < 0.05). Flushing animal food-contact surfaces with low-risk feed is commonly used to reduce cross-contamination in animal feed manufacturing. Thus, four subsequent 50 kg batches of virus-free swine feed were manufactured using the same system to test its impact on decontaminating animal food-contact surfaces. Even after 4 subsequent sequences, animal food-contact surfaces retained viral RNA (28/33 positive samples/total samples), with conveying system being more contaminated than the mixer. A bioassay to test infectivity of dust from animal food-contact surfaces failed to produce infectivity. This study demonstrates the potential widespread viral contamination of surfaces in an animal food manufacturing facility and the difficulty of removing contamination using conventional feed sequencing, which underscores the importance for preventing viruses from entering and contaminating such facilities.

  8. Investigation of the prevalence of Legionella species in domestic hot water systems.

    PubMed

    Bates, M N; Maas, E; Martin, T; Harte, D; Grubner, M; Margolin, T

    2000-06-09

    To investigate the prevalence of Legionella spp. in the hot water systems of a representative sample of Wellington domestic residences with electrically heated hot water systems, and to investigate risk factors (eg water temperature, plumbing materials) for such contamination. 100 households with electrically heated hot water systems in the Wellington area were investigated. Samples of hot water from several hot water outlets were collected, and characteristics of the plumbing system were recorded. Water samples and swabs were cultured and further examined by polymerase chain reaction (PCR) and direct fluorescence antibody (DFA) testing to identify Legionella spp. and serogroups. No Legionella spp. were isolated by culture. PCR tested positive for Legionella in specimens from twelve residences. Six of these were also positive by DFA testing. The only environmental factor found to be associated with the presence of Legionella was recent plumbing work on the hot water system. Five of the twelve PCR-positive residences, and four of the six DFA-confirmed residences had hot water delivery temperatures in excess of 60 degrees C. The results suggest that either Legionellae colonise domestic hot water reticulation systems and/or that the organisms are killed during passage through the hot water tank. Both possibilities may be correct. Further work to characterise the microbial ecology of Legionella-positive hot water distribution systems would be useful, as would the development of improved methods for culturing the organisms from potable water.

  9. Adaptive Resampling Particle Filters for GPS Carrier-Phase Navigation and Collision Avoidance System

    NASA Astrophysics Data System (ADS)

    Hwang, Soon Sik

    This dissertation addresses three problems: 1) adaptive resampling technique (ART) for Particle Filters, 2) precise relative positioning using Global Positioning System (GPS) Carrier-Phase (CP) measurements applied to nonlinear integer resolution problem for GPS CP navigation using Particle Filters, and 3) collision detection system based on GPS CP broadcasts. First, Monte Carlo filters, called Particle Filters (PF), are widely used where the system is non-linear and non-Gaussian. In real-time applications, their estimation accuracies and efficiencies are significantly affected by the number of particles and the scheduling of relocating weights and samples, the so-called resampling step. In this dissertation, the appropriate number of particles is estimated adaptively such that the error of the sample mean and variance stay in bounds. These bounds are given by the confidence interval of a normal probability distribution for a multi-variate state. Two required number of samples maintaining the mean and variance error within the bounds are derived. The time of resampling is determined when the required sample number for the variance error crosses the required sample number for the mean error. Second, the PF using GPS CP measurements with adaptive resampling is applied to precise relative navigation between two GPS antennas. In order to make use of CP measurements for navigation, the unknown number of cycles between GPS antennas, the so called integer ambiguity, should be resolved. The PF is applied to this integer ambiguity resolution problem where the relative navigation states estimation involves nonlinear observations and nonlinear dynamics equation. Using the PF, the probability density function of the states is estimated by sampling from the position and velocity space and the integer ambiguities are resolved without using the usual hypothesis tests to search for the integer ambiguity. The ART manages the number of position samples and the frequency of the resampling step for real-time kinematics GPS navigation. The experimental results demonstrate the performance of the ART and the insensitivity of the proposed approach to GPS CP cycle-slips. Third, the GPS has great potential for the development of new collision avoidance systems and is being considered for the next generation Traffic alert and Collision Avoidance System (TCAS). The current TCAS equipment, is capable of broadcasting GPS code information to nearby airplanes, and also, the collision avoidance system using the navigation information based on GPS code has been studied by researchers. In this dissertation, the aircraft collision detection system using GPS CP information is addressed. The PF with position samples is employed for the CP based relative position estimation problem and the same algorithm can be used to determine the vehicle attitude if multiple GPS antennas are used. For a reliable and enhanced collision avoidance system, three dimensional trajectories are projected using the estimates of the relative position, velocity, and the attitude. It is shown that the performance of GPS CP based collision detecting algorithm meets the accuracy requirements for a precise approach of flight for auto landing with significantly less unnecessary collision false alarms and no miss alarms.

  10. Optical sample-position sensing for electrostatic levitation

    NASA Technical Reports Server (NTRS)

    Sridharan, G.; Chung, S.; Elleman, D.; Whim, W. K.

    1989-01-01

    A comparative study is conducted for optical position-sensing techniques applicable to micro-G conditions sample-levitation systems. CCD sensors are compared with one- and two-dimensional position detectors used in electrostatic particle levitation. In principle, the CCD camera method can be improved from current resolution levels of 200 microns through the incorporation of a higher-pixel device and more complex digital signal processor interface. Nevertheless, the one-dimensional position detectors exhibited superior, better-than-one-micron resolution.

  11. Comparison of GMT presto assay and Roche cobas® 4800 CT/NG assay for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in dry swabs.

    PubMed

    de Waaij, Dewi J; Dubbink, Jan Henk; Peters, Remco P H; Ouburg, Sander; Morré, Servaas A

    2015-11-01

    Urogenital Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) are the most prevalent bacterial STIs worldwide. Molecular tests are the standard for the detection of CT and NG, as these are difficult to culture. The recently introduced CE-IVD marked GMT Presto assay promises to be a valuable addition in CT and NG diagnostics. The advantage of the Presto assay is that it works on many PCR systems and the DNA can be isolated by any system.We compared the Presto assay to the widely used Roche cobas® 4800 CT/NG test for the detection of CT and NG in 612 vaginal and rectal dry collected swabs. Discrepant samples were tested by the TIB MOLBIOL Lightmix Kit 480 HT CT/NG assay. The alloyed gold standard was defined as two concurring Presto and cobas® 4800 results, or, with discrepant Presto and cobas® results, two concurring results of either test together with the Lightmix Kit 480 HT CT/NG assay. For the Presto assay,we observed 77 CT positive (13%) and 22 NG positive (3,6%) vaginal samples, and 41 CT positive (6,7%) and 11 NG positive (1,8%) rectal samples. For the cobas® 4800 assay,we observed 77 CT positive (13%) and 21NG positive (3,4%) vaginal samples, and 39 CT positive (6,4%) and 11 NG positive (1,8%) rectal samples. Ten CT samples were discrepant between Presto and cobas® 4800 CT/NG assays, while two NG samples were discrepant. CT sensitivity in both assays was 100% compared to the alloyed gold standard. The sensitivity was 100% for both vaginal and rectal dry swabs, underlining the suitability of these sample types for detection of CT and NG. The Presto assay is therefore valuable for molecular detection of CT and NG in dry vaginal and rectal swabs.

  12. Tube and column agglutination technology for autocontrol testing.

    PubMed

    Courtney, J E; Vincent, J L; Indrikovs, A J

    2001-01-01

    The incidence of positive autocontrol test results with column agglutination technology is a concern. This study investigates the incidence and significance of positive autocontrols in the ID Micro Typing System (gel) and the Gamma ReACT (ReACT). The study encompassed a total of 1021 randomly selected samples from patients and 95 samples from donors collected during 1 month. The autocontrol testing was carried out according to the manufacturer's instructions for the column agglutination tests. The tube method was carried out using low-ionic-strength solution (LISS). The direct antiglobulin test (DAT) was performed using the tube method, and further investigated with elution studies if warranted. Seventy-nine patient's samples (7.74%) had a positive autocontrol: the gel test, 72 (91.13%); ReACT, 21 (26.58%); and the tube method, 27 (34.18%). Of the 79 positive autocontrols, 44 samples had a negative DAT. Of the samples with positive DAT results, only one possessed a clinically significant antibody, anti-D. Moreover, the same sample also tested positive in all three methods. Column agglutination techniques have increased sensitivity for a positive autocontrol beyond the conventional tube method. However, ReACT and gel tests differ significantly in their frequency of positives. Investigation of the significance of a positive autocontrol in column agglutination technology when the conventional tube method is also positive is suggested.

  13. An Indoor Location-Based Control System Using Bluetooth Beacons for IoT Systems.

    PubMed

    Huh, Jun-Ho; Seo, Kyungryong

    2017-12-19

    The indoor location-based control system estimates the indoor position of a user to provide the service he/she requires. The major elements involved in the system are the localization server, service-provision client, user application positioning technology. The localization server controls access of terminal devices (e.g., Smart Phones and other wireless devices) to determine their locations within a specified space first and then the service-provision client initiates required services such as indoor navigation and monitoring/surveillance. The user application provides necessary data to let the server to localize the devices or allow the user to receive various services from the client. The major technological elements involved in this system are indoor space partition method, Bluetooth 4.0, RSSI (Received Signal Strength Indication) and trilateration. The system also employs the BLE communication technology when determining the position of the user in an indoor space. The position information obtained is then used to control a specific device(s). These technologies are fundamental in achieving a "Smart Living". An indoor location-based control system that provides services by estimating user's indoor locations has been implemented in this study (First scenario). The algorithm introduced in this study (Second scenario) is effective in extracting valid samples from the RSSI dataset but has it has some drawbacks as well. Although we used a range-average algorithm that measures the shortest distance, there are some limitations because the measurement results depend on the sample size and the sample efficiency depends on sampling speeds and environmental changes. However, the Bluetooth system can be implemented at a relatively low cost so that once the problem of precision is solved, it can be applied to various fields.

  14. An Indoor Location-Based Control System Using Bluetooth Beacons for IoT Systems

    PubMed Central

    Huh, Jun-Ho; Seo, Kyungryong

    2017-01-01

    The indoor location-based control system estimates the indoor position of a user to provide the service he/she requires. The major elements involved in the system are the localization server, service-provision client, user application positioning technology. The localization server controls access of terminal devices (e.g., Smart Phones and other wireless devices) to determine their locations within a specified space first and then the service-provision client initiates required services such as indoor navigation and monitoring/surveillance. The user application provides necessary data to let the server to localize the devices or allow the user to receive various services from the client. The major technological elements involved in this system are indoor space partition method, Bluetooth 4.0, RSSI (Received Signal Strength Indication) and trilateration. The system also employs the BLE communication technology when determining the position of the user in an indoor space. The position information obtained is then used to control a specific device(s). These technologies are fundamental in achieving a “Smart Living”. An indoor location-based control system that provides services by estimating user’s indoor locations has been implemented in this study (First scenario). The algorithm introduced in this study (Second scenario) is effective in extracting valid samples from the RSSI dataset but has it has some drawbacks as well. Although we used a range-average algorithm that measures the shortest distance, there are some limitations because the measurement results depend on the sample size and the sample efficiency depends on sampling speeds and environmental changes. However, the Bluetooth system can be implemented at a relatively low cost so that once the problem of precision is solved, it can be applied to various fields. PMID:29257044

  15. Occurrence of Cryptosporidium spp. and Giardia spp. in a public water-treatment system, Paraná, Southern Brazil.

    PubMed

    Almeida, Jonatas Campos; Martins, Felippe Danyel Cardoso; Ferreira Neto, José Maurício; Santos, Maíra Moreira Dos; Garcia, João Luis; Navarro, Italmar Teodorico; Kuroda, Emília Kiyomi; Freire, Roberta Lemos

    2015-01-01

    The purpose of this study was to investigate the occurrence of Cryptosporidium spp. and Giardia spp. in a public water-treatment system. Samples of raw and treated water were collected and concentrated using the membrane filtration technique. Direct Immunofluorescence Test was performed on the samples. DNA extraction using a commercial kit was performed and the DNA extracted was submitted to a nested-PCR reaction (n-PCR) and sequencing. In the immunofluorescence, 2/24 (8.33%) samples of raw water were positive for Giardia spp.. In n-PCR and sequencing, 2/24 (8.33%) samples of raw water were positive for Giardia spp., and 2/24 (8.33%) samples were positive for Cryptosporidium spp.. The sequencing showed Cryptosporidium parvum and Giardia duodenalis DNA. In raw water, there was moderate correlation among turbidity, color and Cryptosporidium spp. and between turbidity and Giardia spp.. The presence of these protozoans in the water indicates the need for monitoring for water-treatment companies.

  16. Implementation of Wi-Fi Signal Sampling on an Android Smartphone for Indoor Positioning Systems.

    PubMed

    Liu, Hung-Huan; Liu, Chun

    2017-12-21

    Collecting and maintaining radio fingerprint for wireless indoor positioning systems involves considerable time and labor. We have proposed the quick radio fingerprint collection (QRFC) algorithm which employed the built-in accelerometer of Android smartphones to implement step detection in order to assist in collecting radio fingerprints. In the present study, we divided the algorithm into moving sampling (MS) and stepped MS (SMS), and describe the implementation of both algorithms and their comparison. Technical details and common errors concerning the use of Android smartphones to collect Wi-Fi radio beacons were surveyed and discussed. The results of signal sampling experiments performed in a hallway measuring 54 m in length showed that in terms of the amount of time required to complete collection of access point (AP) signals, static sampling (SS; a traditional procedure for collecting Wi-Fi signals) took at least 2 h, whereas MS and SMS took approximately 150 and 300 s, respectively. Notably, AP signals obtained through MS and SMS were comparable to those obtained through SS in terms of the distribution of received signal strength indicator (RSSI) and positioning accuracy. Therefore, MS and SMS are recommended instead of SS as signal sampling procedures for indoor positioning algorithms.

  17. Implementation of Wi-Fi Signal Sampling on an Android Smartphone for Indoor Positioning Systems

    PubMed Central

    Liu, Chun

    2017-01-01

    Collecting and maintaining radio fingerprint for wireless indoor positioning systems involves considerable time and labor. We have proposed the quick radio fingerprint collection (QRFC) algorithm which employed the built-in accelerometer of Android smartphones to implement step detection in order to assist in collecting radio fingerprints. In the present study, we divided the algorithm into moving sampling (MS) and stepped MS (SMS), and describe the implementation of both algorithms and their comparison. Technical details and common errors concerning the use of Android smartphones to collect Wi-Fi radio beacons were surveyed and discussed. The results of signal sampling experiments performed in a hallway measuring 54 m in length showed that in terms of the amount of time required to complete collection of access point (AP) signals, static sampling (SS; a traditional procedure for collecting Wi-Fi signals) took at least 2 h, whereas MS and SMS took approximately 150 and 300 s, respectively. Notably, AP signals obtained through MS and SMS were comparable to those obtained through SS in terms of the distribution of received signal strength indicator (RSSI) and positioning accuracy. Therefore, MS and SMS are recommended instead of SS as signal sampling procedures for indoor positioning algorithms. PMID:29267234

  18. A Gas-Spring-Loaded X-Y-Z Stage System for X-ray Microdiffraction Sample Manipulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shu Deming; Cai Zhonghou; Lai, Barry

    2007-01-19

    We have designed and constructed a gas-spring-loaded x-y-z stage system for x-ray microdiffraction sample manipulation at the Advanced Photon Source XOR 2-ID-D station. The stage system includes three DC-motor-driven linear stages and a gas-spring-based heavy preloading structure, which provides antigravity forces to ensure that the stage system keeps high-positioning performance under variable goniometer orientation. Microdiffraction experiments with this new stage system showed significant sample manipulation performance improvement.

  19. A Gas-Spring-Loaded X-Y-Z Stage System for X-ray Microdiffraction Sample Manipulation

    NASA Astrophysics Data System (ADS)

    Shu, Deming; Cai, Zhonghou; Lai, Barry

    2007-01-01

    We have designed and constructed a gas-spring-loaded x-y-z stage system for x-ray microdiffraction sample manipulation at the Advanced Photon Source XOR 2-ID-D station. The stage system includes three DC-motor-driven linear stages and a gas-spring-based heavy preloading structure, which provides antigravity forces to ensure that the stage system keeps high-positioning performance under variable goniometer orientation. Microdiffraction experiments with this new stage system showed significant sample manipulation performance improvement.

  20. Sample Selection for Training Cascade Detectors.

    PubMed

    Vállez, Noelia; Deniz, Oscar; Bueno, Gloria

    2015-01-01

    Automatic detection systems usually require large and representative training datasets in order to obtain good detection and false positive rates. Training datasets are such that the positive set has few samples and/or the negative set should represent anything except the object of interest. In this respect, the negative set typically contains orders of magnitude more images than the positive set. However, imbalanced training databases lead to biased classifiers. In this paper, we focus our attention on a negative sample selection method to properly balance the training data for cascade detectors. The method is based on the selection of the most informative false positive samples generated in one stage to feed the next stage. The results show that the proposed cascade detector with sample selection obtains on average better partial AUC and smaller standard deviation than the other compared cascade detectors.

  1. Sensitivity of bhk-21 cells supplemented with diethylaminoethyl-dextran for detection of street rabies virus in saliva samples.

    PubMed Central

    Larghi, O P; Nebel, A E; Lazaro, L; Savy, V L

    1975-01-01

    A tissue culture system for detecting rabies virus from saliva samples of suspected animals was developed and compared to suckling mouse inoculation. Swab samples were obtained from the mouth of the animal heads received for rabies diagnosis; these swabs were submerged in maintenance medium. The maintenance medium was inoculated intracerebrally into suckling mice and onto BHK-21 cells with diethylaminoethyl (DEAE)-dextran (BHK/DEAE) and without (BHK). Rabies immunofluorescence was performed on the brain of the mice dying during the observation period and also on both tissue culture systems every day after infection. The BHK-DEAE system detected 28 positive samples obtained from 48 rabid animals and the BHK system detected 18. By suckling mouse inoculation only 11 of the same positive samples were detected. A total of 90 samples was studied by the three methods. Rabies virus was detected by the tissue culture methods earlier than by suckling mouse inoculation. The BHK-DEAE method was an economic and fast method for rabies virus detection in saliva samples, which could be used for ecological and pathogenesis studies, as well for rabies diagnosis before the death of the suspected animal. PMID:1100655

  2. A robust variable sampling time BLDC motor control design based upon μ-synthesis.

    PubMed

    Hung, Chung-Wen; Yen, Jia-Yush

    2013-01-01

    The variable sampling rate system is encountered in many applications. When the speed information is derived from the position marks along the trajectory, one would have a speed dependent sampling rate system. The conventional fixed or multisampling rate system theory may not work in these cases because the system dynamics include the uncertainties which resulted from the variable sampling rate. This paper derived a convenient expression for the speed dependent sampling rate system. The varying sampling rate effect is then translated into multiplicative uncertainties to the system. The design then uses the popular μ-synthesis process to achieve a robust performance controller design. The implementation on a BLDC motor demonstrates the effectiveness of the design approach.

  3. A Robust Variable Sampling Time BLDC Motor Control Design Based upon μ-Synthesis

    PubMed Central

    Yen, Jia-Yush

    2013-01-01

    The variable sampling rate system is encountered in many applications. When the speed information is derived from the position marks along the trajectory, one would have a speed dependent sampling rate system. The conventional fixed or multisampling rate system theory may not work in these cases because the system dynamics include the uncertainties which resulted from the variable sampling rate. This paper derived a convenient expression for the speed dependent sampling rate system. The varying sampling rate effect is then translated into multiplicative uncertainties to the system. The design then uses the popular μ-synthesis process to achieve a robust performance controller design. The implementation on a BLDC motor demonstrates the effectiveness of the design approach. PMID:24327804

  4. Growth of Legionella anisa in a model drinking water system to evaluate different shower outlets and the impact of cast iron rust.

    PubMed

    van der Lugt, Wilco; Euser, Sjoerd M; Bruin, Jacob P; Den Boer, Jeroen W; Walker, Jimmy T; Crespi, Sebastian

    2017-11-01

    Legionella continues to be a problem in water systems. This study investigated the influence of different shower mixer faucets, and the influence of the presence of cast iron rust from a drinking water system on the growth of Legionella. The research is conducted using a model of a household containing four drinking water systems. All four systems, which contained standard plumbing components including copper pipes and a water heater, were filled with unchlorinated drinking water. Furthermore, all systems had three different shower faucets: (A) a stainless-steel faucet, (B) a brass-ceramic faucet, and (C) a brass thermostatic faucet. System 1 was solely filled with drinking water. System 2 was filled with drinking water, and cast iron rust. System 3 was contaminated with Legionella, and system 4 was contaminated with a Legionella, and cast iron rust. During a period of 34 months, 450 cold water samples were taken from 15 sample points of the four drinking water systems, and tested for Legionella according to the Dutch Standard (NEN 6265). In system 4, with added cast iron rust, the stainless-steel mixer faucet (A) had the highest concentration of Legionella at >4.3log10CFU/l (>20,000CFU/l) and was positive in 46.4% of samples. In contrast, the stainless-steel mixer faucet (A) of system 3 without cast iron rust showed 14.3% positive samples with a maximum concentration of 3.9log10CFU/l (7600CFU/l) Legionella. Additionally, both contaminated systems (3 and 4), with the brass thermostatic faucet (C), tested positive for Legionella. System 3 in 85.7% of the samples, with a maximum concentration of 4.38log10CFU/l (24,200CFU/l), and system 4 in 64.3% of the samples with a maximum concentration of 4.13log10CFU/l (13.400CFU/l). These results suggest that both the type of faucet used in a drinking water system and the presence or absence of cast iron rust influence the growth of Legionella. Copyright © 2017 Elsevier GmbH. All rights reserved.

  5. Auditing smear microscopy results according to time to detection using the BACTEC™ MGIT™ TB system.

    PubMed

    Elsaghier, A A F

    2015-09-01

    Smear microscopy is a rapid method for the identification of the most infectious patients with mycobacterial infection. Suboptimal smear microscopy may significantly compromise or delay patient isolation and contact tracing. A stringent method for auditing mycobacterial smear results is thus needed. This article proposes an auditing tool based on time to detection (TTD) of culture-positive samples using the automated BACTEC™ MGIT™ 960 TB system. In our study, sputum samples subjected to liquefaction and concentration before staining with a TTD of ≤ 13 days using the BACTEC system should be positive on smear microscopy.

  6. False-positive alarms for bacterial screening of platelet concentrates with BacT/ALERT new-generation plastic bottles: a multicenter pilot study.

    PubMed

    Hundhausen, T; Müller, T H

    2005-08-01

    The microbial detection system BacT/ALERT (bioMérieux) is widely used to monitor bacterial contamination of platelet concentrates (PCs). Recently, the manufacturer introduced polycarbonate culture bottles and a modified pH-sensitive liquid emulsion sensor as microbial growth indicator. This reconfigured assay was investigated in a routine setting. In each of eight transfusion centers, samples from 500 consecutive PCs were monitored for 1 week. For all PCs with a positive BacT/ALERT signal, retained samples and, if available, original PC containers and concomitant red blood cell concentrates were analyzed independently. Initially BacT/ALERT-positive PCs without bacterial identification in any sample were defined as false-positive. BacT/ALERT-positive PCs with bacteria in the first sample only were called potentially positive. PCs with bacteria in the first sample and the same strain in at least one additional sample were accepted as positive. Five PCs (0.13%) were positive, 9 PCs (0.23%) were potentially positive, and 35 PCs (0.9%) were false-positive. The rate of false-positive BacT/ALERT results varied substantially between centers (<0.2%-3.2%). Tracings from false-positive cultures lacked an exponential increase of the signal during incubation. Most of these false-positives were due to malfunctioning cells in various BacT/ALERT incubation units. Careful assessment of individual tracings of samples with positive signals helps to identify malfunctioning incubation units. Their early shutdown or replacement minimizes the high rate of unrectifiable product rejects attributed to false-positive alarms and avoids unnecessary concern of doctors and patients after conversion to a reconfigured BacT/ALERT assay.

  7. STP Position Paper: Recommended Practices for Sampling and Processing the Nervous System (Brain, Spinal Cord, Nerve, and Eye) during Nonclinical General Toxicity Studies

    EPA Science Inventory

    The Society of Toxicologic Pathology charged a Nervous System Sampling Working Group with devising recommended practices to routinely screen the central and peripheral nervous systems in Good Laboratory Practice-type nonclinical general toxicity studies. Brains should be trimmed ...

  8. Characterizing the rapid spread of porcine epidemic diarrhea virus (PEDV) through an animal food manufacturing facility

    PubMed Central

    Schumacher, Loni L.; Huss, Anne R.; Cochrane, Roger A.; Stark, Charles R.; Woodworth, Jason C.; Bai, Jianfa; Poulsen, Elizabeth G.; Chen, Qi; Main, Rodger G.; Zhang, Jianqiang; Gauger, Phillip C.; Ramirez, Alejandro; Derscheid, Rachel J.; Magstadt, Drew M.; Dritz, Steve S.

    2017-01-01

    New regulatory and consumer demands highlight the importance of animal feed as a part of our national food safety system. Porcine epidemic diarrhea virus (PEDV) is the first viral pathogen confirmed to be widely transmissible in animal food. Because the potential for viral contamination in animal food is not well characterized, the objectives of this study were to 1) observe the magnitude of virus contamination in an animal food manufacturing facility, and 2) investigate a proposed method, feed sequencing, to decrease virus decontamination on animal food-contact surfaces. A U.S. virulent PEDV isolate was used to inoculate 50 kg swine feed, which was mixed, conveyed, and discharged into bags using pilot-scale feed manufacturing equipment. Surfaces were swabbed and analyzed for the presence of PEDV RNA by quantitative real-time polymerase chain reaction (qPCR). Environmental swabs indicated complete contamination of animal food-contact surfaces (0/40 vs. 48/48, positive baseline samples/total baseline samples, positive subsequent samples/total subsequent samples, respectively; P < 0.05) and near complete contamination of non-animal food-contact surfaces (0/24 vs. 16/18, positive baseline samples/total baseline samples, positive subsequent samples/total subsequent samples, respectively; P < 0.05). Flushing animal food-contact surfaces with low-risk feed is commonly used to reduce cross-contamination in animal feed manufacturing. Thus, four subsequent 50 kg batches of virus-free swine feed were manufactured using the same system to test its impact on decontaminating animal food-contact surfaces. Even after 4 subsequent sequences, animal food-contact surfaces retained viral RNA (28/33 positive samples/total samples), with conveying system being more contaminated than the mixer. A bioassay to test infectivity of dust from animal food-contact surfaces failed to produce infectivity. This study demonstrates the potential widespread viral contamination of surfaces in an animal food manufacturing facility and the difficulty of removing contamination using conventional feed sequencing, which underscores the importance for preventing viruses from entering and contaminating such facilities. PMID:29095859

  9. A simple dual online ultra-high pressure liquid chromatography system (sDO-UHPLC) for high throughput proteome analysis.

    PubMed

    Lee, Hangyeore; Mun, Dong-Gi; Bae, Jingi; Kim, Hokeun; Oh, Se Yeon; Park, Young Soo; Lee, Jae-Hyuk; Lee, Sang-Won

    2015-08-21

    We report a new and simple design of a fully automated dual-online ultra-high pressure liquid chromatography system. The system employs only two nano-volume switching valves (a two-position four port valve and a two-position ten port valve) that direct solvent flows from two binary nano-pumps for parallel operation of two analytical columns and two solid phase extraction (SPE) columns. Despite the simple design, the sDO-UHPLC offers many advantageous features that include high duty cycle, back flushing sample injection for fast and narrow zone sample injection, online desalting, high separation resolution and high intra/inter-column reproducibility. This system was applied to analyze proteome samples not only in high throughput deep proteome profiling experiments but also in high throughput MRM experiments.

  10. Comparison of the incidence of Listeria on equipment versus environmental sites within dairy processing plants.

    PubMed

    Pritchard, T J; Flanders, K J; Donnelly, C W

    1995-08-01

    This study was undertaken to compare the incidence of Listeria contamination of processing equipment with that of the general dairy processing environment. A total of 378 sponge samples obtained from 21 dairy plants were analyzed for Listeria using three different enrichment media. Use of extended microbiological analysis allowed us to identify 26 Listeria positive sites which would have not been identified had a single test format been employed. Eighty (80) of 378 sites (21.2%) were identified as Listeria positive. Listeria innocua was isolated from 59 of the 80 (73.8%) positive samples, L. monocytogenes was identified in 35 (43.8%) of the positive samples, and L. seeligeri was isolated from 5 (6.3%) of the Listeria positive samples. Positive equipment samples were obtained from 6 of the 21 (28.6%) plants and 19 of the 21 (90.5%) plants had positive environmental sites. Seventeen of the 215 (7.9%) samples from equipment were positive for Listeria species. Eleven of these sites, including 3 holding tanks, 2 table tops, 3 conveyor/chain systems, a pasta filata wheel, a pint milk filler and a brine pre-filter machine, were positive for L. monocytogenes. Nineteen of the 21 (90.5%) plants had positive environmental sites. Sixty-three of the 163 (41.1%) samples from environmental sites were Listeria positive and 24 were positive for L. monocytogenes. Two-tailed student t-test analysis of the mean frequencies indicated that the level of contamination was significantly higher (p < 0.001) in 'environmental' (49.7%) as opposed to 'equipment' samples (7.0%). Our study indicates that environmental contamination with Listeria does not necessarily translate into contamination of equipment within the same plant, and that greater emphasis needs to be placed on the cleaning and sanitizing of the plant environment.

  11. Clinical evaluation of a novel microfluidic device for epitope-independent enrichment of circulating tumour cells in patients with small cell lung cancer.

    PubMed

    Chudziak, Jakub; Burt, Deborah J; Mohan, Sumitra; Rothwell, Dominic G; Mesquita, Bárbara; Antonello, Jenny; Dalby, Suzanne; Ayub, Mahmood; Priest, Lynsey; Carter, Louise; Krebs, Matthew G; Blackhall, Fiona; Dive, Caroline; Brady, Ged

    2016-01-21

    Circulating tumour cells (CTCs) have potential utility as minimally-invasive biomarkers to aid cancer treatment decision making. However, many current CTC technologies enrich CTCs using specific surface epitopes that do not necessarily reflect CTC heterogeneity. Here we evaluated the epitope-independent Parsortix system which enriches CTCs based on size and rigidity using both healthy normal volunteer blood samples spiked with tumour cells and blood samples from patients with small cell lung cancer (SCLC). Blood samples were maintained unfractionated at room temperature for up to 4 days followed by plasma removal for circulating free DNA (cfDNA) isolation and direct application of the remaining cell component to the Parsortix system. For tumour cells expressing the EpCAM cell surface marker the numbers of spiked cells retained using the Parsortix system and by EpCAM-positive selection using CellSearch® were not significantly different, whereas only the Parsortix system showed strong enrichment of cells with undetectable EpCAM expression. In a pilot clinical study we banked both enriched CTCs as well as plasma from SCLC patient blood samples. Upon retrieval of the banked Parsortix cellular samples we could detect cytokeratin positive CTCs in all 12 SCLC patients tested. Interestingly, processing parallel samples from the same patients by EpCAM enrichment using CellSearch® revealed only 83% (10/12) with cytokeratin positive CTCs indicating the Parsortix system is enriching for EpCAM negative SCLC CTCs. Our combined results indicate the Parsortix system is a valuable tool for combined cfDNA isolation and CTC enrichment that enables CTC analysis to be extended beyond dependence on surface epitopes.

  12. Ion photon emission microscope

    DOEpatents

    Doyle, Barney L.

    2003-04-22

    An ion beam analysis system that creates microscopic multidimensional image maps of the effects of high energy ions from an unfocussed source upon a sample by correlating the exact entry point of an ion into a sample by projection imaging of the ion-induced photons emitted at that point with a signal from a detector that measures the interaction of that ion within the sample. The emitted photons are collected in the lens system of a conventional optical microscope, and projected on the image plane of a high resolution single photon position sensitive detector. Position signals from this photon detector are then correlated in time with electrical effects, including the malfunction of digital circuits, detected within the sample that were caused by the individual ion that created these photons initially.

  13. Evaluation of immunohematologic routine methods using the new erythrocyte-magnetized technology on the QWALYS 2 system.

    PubMed

    Schoenfeld, Helge; Bulling, Katia; von Heymann, Christian; Neuner, Bruno; Kalus, Ulrich; Kiesewetter, Holger; Pruss, Axel

    2009-07-01

    QWALYS 2 is a fully automated system for ABO/D grouping, Rh phenotyping, K typing, and antibody screening (ABS). Its new erythrocyte-magnetized technology (EMT) is based on the use of magnetic nanoparticles and avoids centrifugation and washing steps. Overall 499 blood samples were tested with our routine blood bank methods for ABO/D grouping, 313 samples for Rh phenotyping and K typing (microtiter plates; Olympus PK 7200), and 478 samples for ABS (gel centrifugation technique, DiaMed). All samples were tested in parallel with the EMT. In 496 of 499 samples (99.4%), a complete concordance between the observed (QWALYS 2) and the expected results for ABO/D grouping was found. One sample with a weak A in an AB blood group and 2 samples with a weak D were not detected by the QWALYS system. Rh phenotyping and K tests revealed a 100% concordance. In the two ABS techniques, 427 samples were negative in both and 15 samples showed the same antibody specificity in both. Three immunoglobulin M antibodies were as expected negative in EMT and positive by DiaMed. In 32 cases (6.7%), false-positive reactions were observed by EMT due to 22 unspecific reactions (4.6%) and 10 lipemic or fibrinic plasmas (2.1%). One autoantibody was found by EMT only. The EMT is reliably suited to ABO/D grouping, Rh phenotyping, and K testing and is suitable to detect immunoglobulin G red blood cell alloantibodies as well. The rate of false-positive reactions in ABS due to lipemic and fibrinic samples needs to be reduced.

  14. Development features in large-range nanoscale coordinate metrology

    NASA Astrophysics Data System (ADS)

    Gruhlke, Martin; Recknagel, Christian; Rothe, Hendrik

    2008-04-01

    The Nanometer-Coordinate-Measuring-Machine (NCMM) has the ability to scan large areas at nanometer resolution for the purpose of quality assurance of nanostructured products. The device combines a conventional atomic force microscope (AFM) with a precise positioning system. By locating the AFM at a fixed point and moving the sample with the positioning system a scan range of 2.5 x 2.5 x 0.5 cm 3 and a repeatability of 0.1 nm is achieved. Since all movements of the positioning system are measured via laser interferometers, the Abbe-principle is kept in every dimension, the use of materials with a low thermal expansion coefficient (like Zerodur and FeNi36) and an overall coordinate system the system provides unique measurement conditions (traceability to the meter definition; repeatable and fast scans of the region of interest). In the past the NCMM was used to make the first large area scan of a microelectronic sample. Our present work focuses on automating critical dimension measurement through the use of a-priori-knowledge of the sample and optical navigation. A-priori-knowledge can be generated by the use of CAD-Data of the sample or scans with white light interferometry. Another present objective is the optimization of the measurement parameters for specific sample topologies using simulation and also empirical methods like the Ziegler-Nichols method. The need of efficient data processing and handling is also part of our current research.

  15. Comparison of bacteriological culture and PCR for detection of bacteria in ovine milk--sheep are not small cows.

    PubMed

    Zadoks, Ruth N; Tassi, Riccardo; Martin, Elena; Holopainen, Jani; McCallum, Sarah; Gibbons, James; Ballingall, Keith T

    2014-10-01

    Mastitis, inflammation of the mammary gland, is an important cause of disease, mortality, and production losses in dairy and meat sheep. Mastitis is commonly caused by intramammary infection with bacteria, which can be detected by bacterial culture or PCR. PathoProof (Thermo Fisher Scientific Ltd., Vantaa, Finland) is a commercially available real-time PCR system for the detection of bovine mastitis pathogens. Sheep differ from cattle in the bacterial species or bacterial strains that cause mastitis, as well as in the composition of their milk. The aim of this study was to evaluate whether the PathoProof system was suitable for detection of mastitis pathogens in sheep milk. Milk samples were collected aseptically from 219 udder halves of 113 clinically healthy ewes in a single flock. Aliquots were used for bacteriological culture and real-time PCR-based detection of bacteria. For species identified by culture, the diagnosis was confirmed by species-specific conventional PCR or by sequencing of a housekeeping gene. The majority of samples were negative by culture (74.4% of 219 samples) and real-time PCR (82.3% of 192 samples). Agreement was observed for 138 of 192 samples. Thirty-four samples were positive by culture only, mostly due to presence of species that are not covered by primers in the PCR system (e.g., Mannheimia spp.). Two samples were positive for Streptococcus uberis by culture but not by PCR directly from the milk samples. This was not due to inability of the PCR primers to amplify ovine Streptococcus uberis, as diluted DNA extracts from the same samples and DNA extracts from the bacterial isolates were positive by real-time PCR. For samples containing Staphylococcus spp., 11 samples were positive by culture and PCR, 9 by culture only, and 20 by PCR only. Samples that were negative by either method had lower bacterial load than samples that were positive for both methods, whereas no clear relation with species identity was observed. This study provides proof of principle that real-time PCR can be used for detection of mastitis pathogens in ovine milk. Routine use in sheep may require inclusion of primer sets for sheep-specific mastitis pathogens. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  16. The microfluidic bioagent autonomous networked detector (M-BAND): an update. Fully integrated, automated, and networked field identification of airborne pathogens

    NASA Astrophysics Data System (ADS)

    Sanchez, M.; Probst, L.; Blazevic, E.; Nakao, B.; Northrup, M. A.

    2011-11-01

    We describe a fully automated and autonomous air-borne biothreat detection system for biosurveillance applications. The system, including the nucleic-acid-based detection assay, was designed, built and shipped by Microfluidic Systems Inc (MFSI), a new subsidiary of PositiveID Corporation (PSID). Our findings demonstrate that the system and assay unequivocally identify pathogenic strains of Bacillus anthracis, Yersinia pestis, Francisella tularensis, Burkholderia mallei, and Burkholderia pseudomallei. In order to assess the assay's ability to detect unknown samples, our team also challenged it against a series of blind samples provided by the Department of Homeland Security (DHS). These samples included natural occurring isolated strains, near-neighbor isolates, and environmental samples. Our results indicate that the multiplex assay was specific and produced no false positives when challenged with in house gDNA collections and DHS provided panels. Here we present another analytical tool for the rapid identification of nine Centers for Disease Control and Prevention category A and B biothreat organisms.

  17. Positive Wigner functions render classical simulation of quantum computation efficient.

    PubMed

    Mari, A; Eisert, J

    2012-12-07

    We show that quantum circuits where the initial state and all the following quantum operations can be represented by positive Wigner functions can be classically efficiently simulated. This is true both for continuous-variable as well as discrete variable systems in odd prime dimensions, two cases which will be treated on entirely the same footing. Noting the fact that Clifford and Gaussian operations preserve the positivity of the Wigner function, our result generalizes the Gottesman-Knill theorem. Our algorithm provides a way of sampling from the output distribution of a computation or a simulation, including the efficient sampling from an approximate output distribution in the case of sampling imperfections for initial states, gates, or measurements. In this sense, this work highlights the role of the positive Wigner function as separating classically efficiently simulable systems from those that are potentially universal for quantum computing and simulation, and it emphasizes the role of negativity of the Wigner function as a computational resource.

  18. Detection of Wuchereria bancrofti DNA in paired serum and urine samples using polymerase chain reaction-based systems.

    PubMed

    Ximenes, Camila; Brandão, Eduardo; Oliveira, Paula; Rocha, Abraham; Rego, Tamisa; Medeiros, Rafael; Aguiar-Santos, Ana; Ferraz, João; Reis, Christian; Araujo, Paulo; Carvalho, Luiz; Melo, Fabio L

    2014-12-01

    The Global Program for the Elimination of Lymphatic Filariasis (GPELF) aims to eliminate this disease by the year 2020. However, the development of more specific and sensitive tests is important for the success of the GPELF. The present study aimed to standardise polymerase chain reaction (PCR)-based systems for the diagnosis of filariasis in serum and urine. Twenty paired biological urine and serum samples from individuals already known to be positive for Wuchereria bancrofti were collected during the day. Conventional PCR and semi-nested PCR assays were optimised. The detection limit of the technique for purified W. bancrofti DNA extracted from adult worms was 10 fg for the internal systems (WbF/Wb2) and 0.1 fg by using semi-nested PCR. The specificity of the primers was confirmed experimentally by amplification of 1 ng of purified genomic DNA from other species of parasites. Evaluation of the paired urine and serum samples by the semi-nested PCR technique indicated only two of the 20 tested individuals were positive, whereas the simple internal PCR system (WbF/Wb2), which has highly promising performance, revealed that all the patients were positive using both samples. This study successfully demonstrated the possibility of using the PCR technique on urine for the diagnosis of W. bancrofti infection.

  19. Comparison of African swine fever virus prevalence and risk in two contrasting pig-farming systems in South-west and Central Kenya.

    PubMed

    Okoth, E; Gallardo, C; Macharia, J M; Omore, A; Pelayo, V; Bulimo, D W; Arias, M; Kitala, P; Baboon, K; Lekolol, I; Mijele, D; Bishop, R P

    2013-06-01

    We describe a horizontal survey of African swine fever virus (ASFV) prevalence and risk factors associated with virus infection in domestic pigs in two contrasting production systems in Kenya. A free range/tethering, low input production system in Ndhiwa District of South-western Kenya is compared with a medium input stall fed production system in Kiambu District of Central Kenya. Analysis of variance (ANOVA) of data derived from cluster analysis showed that number of animals, number of breeding sows and number of weaner pigs were a significant factor in classifying farms in Nhiwa and Kiambu. Analysis of blood and serum samples using a PCR assay demonstrated an average animal level positivity to ASFV of 28% in two independent samplings in South-western Kenya and 0% PCR positivity in Central Kenya. No animals were sero-positive in either study site using the OIE indirect-ELISA and none of the animals sampled exhibited clinical symptoms of ASF. The farms that contained ASFV positive pigs in Ndhiwa District were located in divisions bordering the Ruma National Park from which bushpig (Potamochoerus larvatus) incursions into farms had been reported. ASFV prevalence (P<0.05) was significantly higher at distances between 6 and 16km from the National Park than at distances closer or further away. One of the 8 bushpigs sampled from the park, from which tissues were obtained was PCR positive for ASFV. The data therefore indicated a potential role for the bushpig in virus transmission in South-western Kenya, but there was no evidence of a direct sylvatic virus transmission cycle in Central Kenya. ASF control strategies implemented in these areas will need to take these epidemiological findings into consideration. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Romer Labs RapidChek®Listeria monocytogenes Test System for the Detection of L. monocytogenes on Selected Foods and Environmental Surfaces.

    PubMed

    Juck, Gregory; Gonzalez, Verapaz; Allen, Ann-Christine Olsson; Sutzko, Meredith; Seward, Kody; Muldoon, Mark T

    2018-04-27

    The Romer Labs RapidChek ® Listeria monocytogenes test system (Performance Tested Method ℠ 011805) was validated against the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook (USDA-FSIS/MLG), U.S. Food and Drug Association Bacteriological Analytical Manual (FDA/BAM), and AOAC Official Methods of Analysis ℠ (AOAC/OMA) cultural reference methods for the detection of L. monocytogenes on selected foods including hot dogs, frozen cooked breaded chicken, frozen cooked shrimp, cured ham, and ice cream, and environmental surfaces including stainless steel and plastic in an unpaired study design. The RapidChek method uses a proprietary enrichment media system, a 44-48 h enrichment at 30 ± 1°C, and detects L. monocytogenes on an immunochromatographic lateral flow device within 10 min. Different L. monocytogenes strains were used to spike each of the matrixes. Samples were confirmed based on the reference method confirmations and an alternate confirmation method. A total of 140 low-level spiked samples were tested by the RapidChek method after enrichment for 44-48 h in parallel with the cultural reference method. There were 88 RapidChek presumptive positives. One of the presumptive positives was not confirmed culturally. Additionally, one of the culturally confirmed samples did not exhibit a presumptive positive. No difference between the alternate confirmation method and reference confirmation method was observed. The respective cultural reference methods (USDA-FSIS/MLG, FDA/BAM, and AOAC/OMA) produced a total of 63 confirmed positive results. Nonspiked samples from all foods were reported as negative for L. monocytogenes by all methods. Probability of detection analysis demonstrated no significant differences in the number of positive samples detected by the RapidChek method and the respective cultural reference method.

  1. Trend of Legionella colonization in hospital water supply.

    PubMed

    D'Alessandro, D; Fabiani, M; Cerquetani, F; Orsi, G B

    2015-01-01

    In many nosocomial Legionella outbreaks water distribution systems are the most frequent source of infection. Considering the hospital waterline old age, an investigation on colonization by Legionella spp was carried out in order to evaluate the pipeline system weaknesses and to implement environmental preventive measures. From 2004 to 2010, overall 97 samples from the water line were collected. The samples were analyzed according to the italian Legionella spp standard methods; water temperature, pH and residual free chlorine were determined at the time of collection. X2 test, exact-test and t-test were used to compare proportions and means. Overall 28 samples (23.7%) were positive for Legionella spp, and five of them (17.9%) exceeded the threshold level >104 cfu/L. The number of positive samples varied along the years, showing a significant increasing trend (X2 for trend = 11.5; p<0.01), but most occurred in 2008 (53,6%), when the hospital underwent major building reconstruction. Samples positive for Legionella spp by comparison to negative ones showed a lower free chlorine concentration (0.08 mg/L vs 0.15 mg/L) and a higher water temperature (46.1° vs 42.7°). Actually the percentage of positive samples decreased significantly with the increasing in free chlorine in the water (X2 for trend = 8.53; p<0.01). The samples collected at the connection between public water line with the hospital supply network were always free from Legionella. All hospital buildings were colonized by Legionella spp, although 80% of samples >104 cfu/L occurred in the C-building. No cases of nosocomial legionellosis were reported during the study period. Hospital water system showed a diffuse colonization by Legionella spp, although the degree of contamination reached the threshold level (>104 cfu/L) only in a small percentage of samples, showing a substantial effectiveness of the control measures applied.

  2. Combinatorial Study of the Li-Ni-Mn-Co Oxide Pseudoquaternary System for Use in Li-Ion Battery Materials Research.

    PubMed

    Brown, Colby R; McCalla, Eric; Watson, Cody; Dahn, J R

    2015-06-08

    Combinatorial synthesis has proven extremely effective in screening for new battery materials for Li-ion battery electrodes. Here, a study in the Li-Ni-Mn-Co-O system is presented, wherein samples with nearly 800 distinct compositions were prepared using a combinatorial and high-throughput method to screen for single-phase materials of high interest as next generation positive electrode materials. X-ray diffraction is used to determine the crystal structure of each sample. The Gibbs' pyramid representing the pseudoquaternary system was studied by making samples within three distinct pseudoternary planes defined at fractional cobalt metal contents of 10%, 20%, and 30% within the Li-Ni-Mn-Co-O system. Two large single-phase regions were observed in the system: the layered region (ordered rocksalt) and cubic spinel region; both of which are of interest for next-generation positive electrodes in lithium-ion batteries. These regions were each found to stretch over a wide range of compositions within the Li-Ni-Mn-Co-O pseudoquaternary system and had complex coexistence regions existing between them. The sample cooling rate was found to have a significant effect on the position of the phase boundaries of the single-phase regions. The results of this work are intended to guide further research by narrowing the composition ranges worthy of study and to illustrate the broad range of applications where solution-based combinatorial synthesis can have significant impact.

  3. A problem of hospital hygiene: the presence of aspergilli in hospital wards with different air-conditioning features.

    PubMed

    Perdelli, Fernanda; Sartini, Marina; Spagnolo, Anna Maria; Dallera, Maurizio; Lombardi, Roberto; Cristina, Maria Luisa

    2006-06-01

    A total of 1,030 microbiological samples were taken in 3 hospital wards with different air-conditioning features: no conditioning system (ward A), a conditioning system equipped with minimum efficiency reporting value (MERV) filters (ward B), and a conditioning system thoroughly maintained and equipped with high-efficiency particulate air (HEPA) filters (absolute) (ward C). The air in each ward was sampled, and the bacterial and fungal concentrations were determined by active and passive methods. The concentration of fungi on surfaces was also determined. Active sampling showed positive samples in wards A and B only, with average values of 0.50 colony-forming units (CFU)/m(3) (95% CI, 0.30 to 0.70) in A and 0.16 CFU/m(3) (95% CI, 0.13 to 0.20) in B. Passive sampling was positive only in ward A (mean, 0.14 CFU/cm(2)/h; 95% CI, 0.13 to 0.15). Aspergillus was found in 27% and 22% of sampled surfaces in wards A and B, respectively, but in no samples from ward C. The most commonly found species was A. fumigatus (76% of cases in A and 34% of cases in B). The results show that the use of air-conditioning systems markedly reduces the concentration of aspergilli in the environment. Proper maintenance of these systems is clearly fundamental if their efficacy is to be ensured.

  4. Automated position control of a surface array relative to a liquid microjunction surface sampler

    DOEpatents

    Van Berkel, Gary J.; Kertesz, Vilmos; Ford, Michael James

    2007-11-13

    A system and method utilizes an image analysis approach for controlling the probe-to-surface distance of a liquid junction-based surface sampling system for use with mass spectrometric detection. Such an approach enables a hands-free formation of the liquid microjunction used to sample solution composition from the surface and for re-optimization, as necessary, of the microjunction thickness during a surface scan to achieve a fully automated surface sampling system.

  5. Fast and robust control of nanopositioning systems: Performance limits enabled by field programmable analog arrays.

    PubMed

    Baranwal, Mayank; Gorugantu, Ram S; Salapaka, Srinivasa M

    2015-08-01

    This paper aims at control design and its implementation for robust high-bandwidth precision (nanoscale) positioning systems. Even though modern model-based control theoretic designs for robust broadband high-resolution positioning have enabled orders of magnitude improvement in performance over existing model independent designs, their scope is severely limited by the inefficacies of digital implementation of the control designs. High-order control laws that result from model-based designs typically have to be approximated with reduced-order systems to facilitate digital implementation. Digital systems, even those that have very high sampling frequencies, provide low effective control bandwidth when implementing high-order systems. In this context, field programmable analog arrays (FPAAs) provide a good alternative to the use of digital-logic based processors since they enable very high implementation speeds, moreover with cheaper resources. The superior flexibility of digital systems in terms of the implementable mathematical and logical functions does not give significant edge over FPAAs when implementing linear dynamic control laws. In this paper, we pose the control design objectives for positioning systems in different configurations as optimal control problems and demonstrate significant improvements in performance when the resulting control laws are applied using FPAAs as opposed to their digital counterparts. An improvement of over 200% in positioning bandwidth is achieved over an earlier digital signal processor (DSP) based implementation for the same system and same control design, even when for the DSP-based system, the sampling frequency is about 100 times the desired positioning bandwidth.

  6. Using Relational Developmental Systems Theory to Link Program Goals, Activities, and Outcomes: The Sample Case of the 4-H Study of Positive Youth Development

    ERIC Educational Resources Information Center

    Lerner, Richard M.; Wang, Jun; Chase, Paul A.; Gutierrez, Akira S.; Harris, Elise M.; Rubin, Rachel O.; Yalin, Ceren

    2014-01-01

    In contemporary developmental science, relational development systems models have been used to frame the positive youth development (PYD) perspective, which posits that youth will thrive when there is alignment between their strengths and ecological resources in their context. Evidence from the 4-H Study of PYD indicates that out-of-school-time…

  7. 40 CFR 141.859 - Coliform treatment technique triggers and assessment requirements for protection against...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... per month, the system has two or more total coliform-positive samples in the same month. (iii) The... second Level 1 trigger as defined in paragraph (a)(1) of this section, within a rolling 12-month period...) Level 1 treatment technique triggers. (i) For systems taking 40 or more samples per month, the system...

  8. 40 CFR 141.859 - Coliform treatment technique triggers and assessment requirements for protection against...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... per month, the system has two or more total coliform-positive samples in the same month. (iii) The... second Level 1 trigger as defined in paragraph (a)(1) of this section, within a rolling 12-month period...) Level 1 treatment technique triggers. (i) For systems taking 40 or more samples per month, the system...

  9. Controlling aliased dynamics in motion systems? An identification for sampled-data control approach

    NASA Astrophysics Data System (ADS)

    Oomen, Tom

    2014-07-01

    Sampled-data control systems occasionally exhibit aliased resonance phenomena within the control bandwidth. The aim of this paper is to investigate the aspect of these aliased dynamics with application to a high performance industrial nano-positioning machine. This necessitates a full sampled-data control design approach, since these aliased dynamics endanger both the at-sample performance and the intersample behaviour. The proposed framework comprises both system identification and sampled-data control. In particular, the sampled-data control objective necessitates models that encompass the intersample behaviour, i.e., ideally continuous time models. Application of the proposed approach on an industrial wafer stage system provides a thorough insight and new control design guidelines for controlling aliased dynamics.

  10. Prevalence of anti-DFS70 antibodies in patients with and without systemic autoimmune rheumatic diseases.

    PubMed

    Shovman, Ora; Gilburd, Boris; Chayat, Chen; Amital, Howard; Langevitz, Pnina; Watad, Abdulla; Guy, Adi; Perez, Dolores; Azoulay, Danielle; Blank, Miri; Segal, Yael; Bentow, Chelsea; Mahler, Michael; Shoenfeld, Yehuda

    2018-01-01

    Autoantibodies to the dense fine speckled 70 (DFS70) antigen are common among antinuclear antibodies (ANA) positive healthy individuals (HI). We assessed the prevalence of anti-DFS70 antibodies in patients with and without ANA-associated rheumatic diseases (AARDs) by two methods: chemiluminescent immunoassay (CIA) and an indirect immunofluorescence (IIF) assay based on immunoadsorption for DFS70. Fifty-one ANA-positive sera samples from patients with confirmed clinical diagnosis of AARD, 92 samples from HI and 85 samples submitted to a reference laboratory for routine ANA testing were evaluated for the presence of anti-DFS70 antibodies. The samples were evaluated by QUANTA Flash DFS70 CIA using BIO-FLASH instrument and by NOVA Lite selected HEp-2 kit on NOVA View - an automated IIF system. Sera with DFS positive pattern were pre-absorbed with highly purified human DFS70 antigen, and then tested again. Twenty-four samples (10.5%) tested by QUANTA Flash DFS70 CIA were positive for anti-DFS70 antibodies. The prevalence of monospecific anti-DFS70 antibodies was significantly higher in healthy subjects than in patients with AARDs (10.9% vs. 1.9%, p=0.02). The frequency of anti-DFS70 antibodies in samples submitted for routine ANA testing was 15.2%. A very good agreement was found between CIA and the DFS pattern identified by the automated HEp-2 IIF (kappa=0.97). In 80% of the samples obtained from patients without AARDs, immunoadsorption effectively inhibited the anti-DFS70 antibodies. The data confirm that mono-specific anti-DFS70 antibodies are a strong discriminator between ANA positive HI and AARD patients, and their evaluation should be included in ANA testing algorithms.

  11. Supporting Positive Behaviour in Alberta Schools: A School-Wide Approach

    ERIC Educational Resources Information Center

    Mackenzie, Nancy

    2008-01-01

    Drawing on current research and best practices, this three-part resource, "Supporting Positive Behaviour in Alberta Schools," provides information, strategies, stories from schools and sample tools for systematically teaching, supporting and reinforcing positive behaviour. This integrated system of school-wide, classroom management, and…

  12. Uniform Laser Excitation And Detection In Capillary Array Electrophoresis System And Method.

    DOEpatents

    Li, Qingbo; Zhou, Songsan; Liu, Changsheng

    2003-10-07

    A capillary electrophoresis system comprises capillaries positioned in parallel to each other forming a plane. The capillaries are configured to allow samples to migrate. A light source is configured to illuminate the capillaries and the samples therein. This causes the samples to emit light. A lens is configured to receive the light emitted by the samples and positioned directly over a first group of the capillaries and obliquely over a second group of the capillaries. The light source is further configured to illuminate the second group of capillaries more than the first group of the capillaries such that amount of light received by the lens from the first group of capillaries is substantially identical to amount of light received from the second group of capillaries when an identical amount of the samples is migrating through the first and second group capillaries.

  13. An indoor positioning technology in the BLE mobile payment system

    NASA Astrophysics Data System (ADS)

    Han, Tiantian; Ding, Lei

    2017-05-01

    Mobile payment system for large supermarkets, the core function is through the BLE low-power Bluetooth technology to achieve the amount of payment in the mobile payment system, can through an indoor positioning technology to achieve value-added services. The technology by collecting Bluetooth RSSI, the fingerprint database of sampling points corresponding is established. To get Bluetooth module RSSI by the AP. Then, to use k-Nearest Neighbor match the value of the fingerprint database. Thereby, to help businesses find customers through the mall location, combined settlement amount of the customer's purchase of goods, to analyze customer's behavior. When the system collect signal strength, the distribution of the sampling points of RSSI is analyzed and the value is filtered. The system, used in the laboratory is designed to demonstrate the feasibility.

  14. Occurrence and parameters of frequency of Legionella in warm water systems of hospitals and hotels in Lower Saxony.

    PubMed

    Habicht, W; Müller, H E

    1988-03-01

    A total of 1241 water samples was investigated from 103 hospitals and 62 hotels in Lower Saxony 1985-87. 331 of 949 samples from hospitals and 26 of 292 samples from hotels were Legionella positive. All together 70% of the hospitals and 18% of the hotels investigated were Legionella positive, and 836 strains of Legionella were isolated (Table 1). As they could be diagnosed they belong to L. pneumophila SG1 306 strains, SG2 36 strains, SG3 127 strains, SG4 45 strain, SG5 29 strain, SG6 106 strains, SG9 13 strains and SG10 13 strains. Further 134 strains belonging to L. pneumophila but not to SG1-SG12 show cross reactions with serogroups 5, 8, and 10. Finally, 16 strains belong to L. dumoffii and 1 strain to L. anisa (Table 2). The following parameters of water samples were studied, too: temperature, pH value, conductivity, concentration of iron, of organic matter, of other bacteria, occurrence of amoebas, and the materials of water plumbing systems. Most samples contained concentrations of Legionella in the range of 10(1)-10(3) CFU/ml, highest concentrations were 10(5) CFU/ml (Fig. 1). Most frequently, Legionella were isolated within the range of temperature of 35-45 degrees C. However, a few of the water samples were positive for Legionella even up to 66 degrees C (Fig. 3). The conductivity has no and the pH value (Fig. 2) has only little influence on the occurrence of Legionella. There is a positive correlation between concentration of iron and frequency of Legionella (Fig. 4). Also organic matter (Fig. 6) and amoebas (Table 3) seem to enhance the occurrence of Legionella. Plumbing systems consisting of copper showed an inhibitory effect on Legionella during the first five years, whereas no effect could be detected in older systems (Fig. 5).

  15. Method and system for laser-based formation of micro-shapes in surfaces of optical elements

    DOEpatents

    Bass, Isaac Louis; Guss, Gabriel Mark

    2013-03-05

    A method of forming a surface feature extending into a sample includes providing a laser operable to emit an output beam and modulating the output beam to form a pulse train having a plurality of pulses. The method also includes a) directing the pulse train along an optical path intersecting an exposed portion of the sample at a position i and b) focusing a first portion of the plurality of pulses to impinge on the sample at the position i. Each of the plurality of pulses is characterized by a spot size at the sample. The method further includes c) ablating at least a portion of the sample at the position i to form a portion of the surface feature and d) incrementing counter i. The method includes e) repeating steps a) through d) to form the surface feature. The sample is free of a rim surrounding the surface feature.

  16. Note: A wide temperature range MOKE system with annealing capability.

    PubMed

    Chahil, Narpinder Singh; Mankey, G J

    2017-07-01

    A novel sample stage integrated with a longitudinal MOKE system has been developed for wide temperature range measurements and annealing capabilities in the temperature range 65 K < T < 760 K. The sample stage incorporates a removable platen and copper block with inserted cartridge heater and two thermocouple sensors. It is supported and thermally coupled to a cold finger with two sapphire bars. The sapphire based thermal coupling enables the system to perform at higher temperatures without adversely affecting the cryostat and minimizes thermal drift in position. In this system the hysteresis loops of magnetic samples can be measured simultaneously while annealing the sample in a magnetic field.

  17. A new laboratory-based surveillance system (Respiratory DataMart System) for influenza and other respiratory viruses in England: results and experience from 2009 to 2012.

    PubMed

    Zhao, H; Green, H; Lackenby, A; Donati, M; Ellis, J; Thompson, C; Bermingham, A; Field, J; Sebastianpillai, P; Zambon, M; Watson, Jm; Pebody, R

    2014-01-23

    During the 2009 influenza A(H1N1) pandemic, a new laboratory-based virological sentinel surveillance system, the Respiratory DataMart System (RDMS), was established in a network of 14 Health Protection Agency (now Public Health England (PHE)) and National Health Service (NHS) laboratories in England. Laboratory results (both positive and negative) were systematically collected from all routinely tested clinical respiratory samples for a range of respiratory viruses including influenza, respiratory syncytial virus (RSV), rhinovirus, parainfluenza virus, adenovirus and human metapneumovirus (hMPV). The RDMS also monitored the occurrence of antiviral resistance of influenza viruses. Data from the RDMS for the 2009–2012 period showed that the 2009 pandemic influenza virus caused three waves of activity with different intensities during the pandemic and post pandemic periods. Peaks in influenza A(H1N1)pdm09 positivity (defined as number of positive samples per total number of samples tested) were seen in summer and autumn in 2009, with slightly higher peak positivity observed in the first post-pandemic season in 2010/2011. The influenza A(H1N1)pdm09 virus strain almost completely disappeared in the second postpandemic season in 2011/2012. The RDMS findings are consistent with other existing community-based virological and clinical surveillance systems. With a large sample size, this new system provides a robust supplementary mechanism, through the collection of routinely available laboratory data at minimum extra cost, to monitor influenza as well as other respiratory virus activity. A near real-time, daily reporting mechanism in the RDMS was established during the London 2012 Olympic and Paralympic Games. Furthermore, this system can be quickly adapted and used to monitor future influenza pandemics and other major outbreaks of respiratory infectious disease, including novel pathogens.

  18. Thermometry of the system “heat-resistant sample - incident plasma stream”

    NASA Astrophysics Data System (ADS)

    Sargsyan, M. A.; Chinnov, V. F.; Kavyrshin, D. I.; Gadzhiev, M. Kh; Khromov, M. A.; Chistolinov, A. V.; Senchenko, V. N.

    2017-11-01

    To study the interacting system “heat-resistant sample - an incident plasma stream” a setup of synchronized measurement equipment was developed and tested that recorded the main parameters of such interaction. Heat resistance tests were carried out on the samples of MPG-6 grade isotropic graphite, and samples of pyrolytic graphite that were subjected to a long (60 … 100 s) exposure to nitrogen, argon and air plasma streams at atmospheric pressure. As plasma generators a series of plasma torches with a vortex stabilization of the stream and an expanding anode channels was used. The temperature and composition of the plasma in the jet and near the sample were determined using two AvaSpec2048 and AvaSpec3648 scanning optical spectrometers and the MS5402i spectrograph with the Andor matrix at its outlet. The surface temperature of the sample was determined in real time using three independent ways: two pyrometric systems - a high-speed micro-pyrometer FMP1001 and a two-position visualization of the heated sample by high-speed Motion Pro X3 and VS-FAST cameras, and the spectral analysis of the wide-range thermal radiation of the samples. The main method for determining the rate of material loss during the action of a plasma jet on it was to analyze a two-position synchronous visualization of the “jet-sample” system. When a crater was formed on the surface of the sample under the “dagger” effect of a plasma jet, a video recording system of the crater zone was used, backlit using the “laser knife” method.

  19. STP Position Paper: Recommended Best Practices for Sampling, Processing and Analysis of the Peripheral Nervous System (Nerves and Somatic and Autonomic Ganglia) during Nonclinical Toxicity Studies

    EPA Science Inventory

    These Society of Toxicologic Pathology “best” practice recommendations should ensure consistent sampling, processing, and evaluation of the peripheral nervous system (PNS). For toxicity studies where neurotoxicity is not anticipated (Situation 1), PNS evaluation may be limited...

  20. NBS work on neutron resonance radiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schrack, R.A.

    1987-01-01

    NBS has been engaged in a wide-ranging program in Neutron Resonance Radiography utilizing both one- and two-dimensional position-sensitive neutron detectors. The ability to perform a position-sensitive assay of up to 16 isotopes in a complex matrix has been demonstrated for a wide variety of sample types, including those with high gamma activity. A major part of the program has been the development and application of the microchannel-plate-based position-sensitive neutron detector. This detector system has high resolution and sensitivity, together with adequate speed of response to be used with neutron time-of-flight techniques. This system has demonstrated the ability to simultaneously imagemore » three isotopes in a sample with no interference.« less

  1. Further support for association between GWAS variant for positive emotion and reward systems.

    PubMed

    Lancaster, T M; Ihssen, N; Brindley, L M; Linden, D E J

    2017-01-31

    A recent genome-wide association study (GWAS) identified a significant single-nucleotide polymorphism (SNP) for trait-positive emotion at rs322931 on chromosome 1, which was also associated with brain activation in the reward system of healthy individuals when observing positive stimuli in a functional magnetic resonance imaging (fMRI) study. In the current study, we aimed to further validate the role of variation at rs322931 in reward processing. Using a similar fMRI approach, we use two paradigms that elicit a strong ventral striatum (VS) blood oxygen-level dependency (BOLD) response in a sample of young, healthy individuals (N=82). In the first study we use a similar picture-viewing task to the discovery sample (positive>neutral stimuli) to replicate an effect of the variant on emotion processing. In the second study we use a probabilistic reversal learning procedure to identify reward processing during decision-making under uncertainly (reward>punishment). In a region of interest (ROI) analysis of the bilateral VS, we show that the rs322931 genotype was associated with BOLD in the left VS during the positive>neutral contrast (P ROI-CORRECTED =0.045) and during the reward>punishment contrast (P ROI-CORRECTED =0.018), although the effect of passive picture viewing was in the opposite direction from that reported in the discovery sample. These findings suggest that the recently identified GWAS hit may influence positive emotion via individual differences in activity in the key hubs of the brain's reward system. Furthermore, these effects may not be limited to the passive viewing of positive emotional scenes, but may also be observed during dynamic decision-making. This study suggests that future studies of this GWAS locus may yield further insight into the biological mechanisms of psychopathologies characterised by deficits in reward processing and positive emotion.

  2. Total coliform and E. coli in public water systems using undisinfected ground water in the United States.

    PubMed

    Messner, Michael J; Berger, Philip; Javier, Julie

    2017-06-01

    Public water systems (PWSs) in the United States generate total coliform (TC) and Escherichia coli (EC) monitoring data, as required by the Total Coliform Rule (TCR). We analyzed data generated in 2011 by approximately 38,000 small (serving fewer than 4101 individuals) undisinfected public water systems (PWSs). We used statistical modeling to characterize a distribution of TC detection probabilities for each of nine groupings of PWSs based on system type (community, non-transient non-community, and transient non-community) and population served (less than 101, 101-1000 and 1001-4100 people). We found that among PWS types sampled in 2011, on average, undisinfected transient PWSs test positive for TC 4.3% of the time as compared with 3% for undisinfected non-transient PWSs and 2.5% for undisinfected community PWSs. Within each type of PWS, the smaller systems have higher median TC detection than the larger systems. All TC-positive samples were assayed for EC. Among TC-positive samples from small undisinfected PWSs, EC is detected in about 5% of samples, regardless of PWS type or size. We evaluated the upper tail of the TC detection probability distributions and found that significant percentages of some system types have high TC detection probabilities. For example, assuming the systems providing data are nationally-representative, then 5.0% of the ∼50,000 small undisinfected transient PWSs in the U.S. have TC detection probabilities of 20% or more. Communities with such high TC detection probabilities may have elevated risk of acute gastrointestinal (AGI) illness - perhaps as great or greater than the attributable risk to drinking water (6-22%) calculated for 14 Wisconsin community PWSs with much lower TC detection probabilities (about 2.3%, Borchardt et al., 2012). Published by Elsevier GmbH.

  3. Bacteria-free water for automatic washer-disinfectors: an impossible dream?

    PubMed

    Cooke, R P; Whymant-Morris, A; Umasankar, R S; Goddard, S V

    1998-05-01

    The ability of a new automatic washer-disinfector system (AWDS), fitted with a water filtration system to provide bacteria-free water and so avoid the risk of mycobacterial contamination of fibreoptic bronchoscopes, was examined. Four new Astec 'MP' Safescope washer-disinfectors, with coarse and fine (0.2 micron) filters attached close to the outlet taps, were supplied with non-softened mains water. Water samples from the tank supply and outlet taps were regularly assessed for bacterial quality over a six-month period. Outlet samples were also analysed after fine filter change and purgation with peracetic acid. All bronchoalveolar lavage specimens (BALS) were stained and cultured for mycobacteria. Only 13 out of 53 outlet samples (24%) were culture-negative. There was no improvement after filter change. Residual anti-bacterial effect of peracetic acid lasted up to 48 h following AWDS purgation. No tank samples were bacteria-free. Sixty BALS were processed, two samples were culture-positive and grew M. tuberculosis and one was also smear-positive. Though mycobacterial contamination of bronchoscopes was not evident, the water filtration system was unable to reliably provide sterile rinse water.

  4. Salmonella detection in poultry samples. Comparison of two commercial real-time PCR systems with culture methods for the detection of Salmonella spp. in environmental and fecal samples of poultry.

    PubMed

    Sommer, D; Enderlein, D; Antakli, A; Schönenbrücher, H; Slaghuis, J; Redmann, T; Lierz, M

    2012-01-01

    The efficiency of two commercial PCR methods based on real-time technology, the foodproof® Salmonella detection system and the BAX® PCR Assay Salmonella system was compared to standardized culture methods (EN ISO 6579:2002 - Annex D) for the detection of Salmonella spp. in poultry samples. Four sample matrices (feed, dust, boot swabs, feces) obtained directly from poultry flocks, as well as artificially spiked samples of the same matrices, were used. All samples were tested for Salmonella spp. using culture methods first as the gold standard. In addition samples spiked with Salmonella Enteridis were tested to evaluate the sensitivity of both PCR methods. Furthermore all methods were evaluated in an annual ring-trial of the National Salmonella Reference Laboratory of Germany. Salmonella detection in the matrices feed, dust and boot swabs were comparable in both PCR systems whereas the results from feces differed markedly. The quality, especially the freshness, of the fecal samples had an influence on the sensitivity of the real-time PCR and the results of the culture methods. In fresh fecal samples an initial spiking level of 100cfu/25g Salmonella Enteritidis was detected. Two-days-dried fecal samples allowed the detection of 14cfu/25g. Both real- time PCR protocols appear to be suitable for the detection of Salmonella spp. in all four matrices. The foodproof® system detected eight samples more to be positive compared to the BAX® system, but had a potential false positive result in one case. In 7-days-dried samples none of the methods was able to detect Salmonella likely through letal cell damage. In general the advantage of PCR analyses over the culture method is the reduction of working time from 4-5 days to only 2 days. However, especially for the analysis of fecal samples official validation should be conducted according to the requirement of EN ISO6579:2002 - Annex D.

  5. Associations between fecal indicator bacteria prevalence and demographic data in private water supplies in Virginia.

    PubMed

    Smith, Tamara; Krometis, Leigh-Anne H; Hagedorn, Charles; Lawrence, Annie H; Benham, Brian; Ling, Erin; Ziegler, Peter; Marmagas, Susan West

    2014-12-01

    Over 1.7 million Virginians rely on private water sources to provide household water. The heaviest reliance on these systems occurs in rural areas, which are often underserved with respect to available financial resources and access to environmental health education. This study aimed to identify potential associations between concentrations of fecal indicator bacteria (FIB) (coliforms, Escherichia coli) in over 800 samples collected at the point-of-use from homes with private water supply systems and homeowner-provided demographic data (household income and education). Of the 828 samples tested, 349 (42%) of samples tested positive for total coliform and 55 (6.6%) tested positive for E. coli. Source tracking efforts targeting optical brightener concentrations via fluorometry and the presence of a human-specific Bacteroides marker via quantitative real-time polymerase chain reaction (qPCR) suggest possible contamination from human septage in over 20 samples. Statistical methods implied that household income has an association with the proportion of samples positive for total coliform, though the relationship between education level and FIB is less clear. Further exploration of links between demographic data and private water quality will be helpful in building effective strategies to improve rural drinking water quality.

  6. Sample introduction apparatus for a flow cytometer

    DOEpatents

    Van den Engh, Ger

    1998-01-01

    A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning HPLC tubing and fittings may be used in a manner which facilitates removable of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it.

  7. Sample introduction apparatus for a flow cytometer

    DOEpatents

    Van den Engh, G.

    1998-03-10

    A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning HPLC tubing and fittings may be used in a manner which facilitates removable of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it. 3 figs.

  8. Soft Real-Time PID Control on a VME Computer

    NASA Technical Reports Server (NTRS)

    Karayan, Vahag; Sander, Stanley; Cageao, Richard

    2007-01-01

    microPID (uPID) is a computer program for real-time proportional + integral + derivative (PID) control of a translation stage in a Fourier-transform ultraviolet spectrometer. microPID implements a PID control loop over a position profile at sampling rate of 8 kHz (sampling period 125microseconds). The software runs in a strippeddown Linux operating system on a VersaModule Eurocard (VME) computer operating in real-time priority queue using an embedded controller, a 16-bit digital-to-analog converter (D/A) board, and a laser-positioning board (LPB). microPID consists of three main parts: (1) VME device-driver routines, (2) software that administers a custom protocol for serial communication with a control computer, and (3) a loop section that obtains the current position from an LPB-driver routine, calculates the ideal position from the profile, and calculates a new voltage command by use of an embedded PID routine all within each sampling period. The voltage command is sent to the D/A board to control the stage. microPID uses special kernel headers to obtain microsecond timing resolution. Inasmuch as microPID implements a single-threaded process and all other processes are disabled, the Linux operating system acts as a soft real-time system.

  9. Impact of Implementation of an Automated Liquid Culture System on Diagnosis of Tuberculous Pleurisy.

    PubMed

    Lee, Byung Hee; Yoon, Seong Hoon; Yeo, Hye Ju; Kim, Dong Wan; Lee, Seung Eun; Cho, Woo Hyun; Lee, Su Jin; Kim, Yun Seong; Jeon, Doosoo

    2015-07-01

    This study was conducted to evaluate the impact of implementation of an automated liquid culture system on the diagnosis of tuberculous pleurisy in an HIV-uninfected patient population. We retrospectively compared the culture yield, time to positivity, and contamination rate of pleural effusion samples in the BACTEC Mycobacteria Growth Indicator Tube 960 (MGIT) and Ogawa media among patients with tuberculous pleurisy. Out of 104 effusion samples, 43 (41.3%) were culture positive on either the MGIT or the Ogawa media. The culture yield of MGIT was higher (40.4%, 42/104) than that of Ogawa media (18.3%, 19/104) (P<0.001). One of the samples was positive only on the Ogawa medium. The median time to positivity was faster in the MGIT (18 days, range 8-32 days) than in the Ogawa media (37 days, range 20-59 days) (P<0.001). No contamination or growth of nontuberculous mycobacterium was observed on either of the culture media. In conclusion, the automated liquid culture system could provide approximately twice as high yields and fast results in effusion culture, compared to solid media. Supplemental solid media may have a limited impact on maximizing sensitivity in effusion culture; however, further studies are required.

  10. In-house validation study of the DuPont Qualicon BAX system Q7 instrument with the BAX system PCR Assay for Salmonella (modification of AOAC Official Method 2003.09 and AOAC Research Institute Performance-Tested Method 100201).

    PubMed

    Tice, George; Andaloro, Bridget; White, H Kirk; Bolton, Lance; Wang, Siqun; Davis, Eugene; Wallace, Morgan

    2009-01-01

    In 2006, DuPont Qualicon introduced the BAX system Q7 instrument for use with its assays. To demonstrate the equivalence of the new and old instruments, a validation study was conducted using the BAX system PCR Assay for Salmonella, AOAC Official Method 2003.09, on three food types. The foods were simultaneously analyzed with the BAX system Q7 instrument and either the U.S. Food and Drug Administration Bacteriological Analytical Manual or the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook reference method for detecting Salmonella. Comparable performance between the BAX system and the reference methods was observed. Of the 75 paired samples analyzed, 39 samples were positive by both the BAX system and reference methods, and 36 samples were negative by both the BAX system and reference methods, demonstrating 100% correlation. Inclusivity and exclusivity for the BAX system Q7 instrument were also established by testing 50 Salmonella strains and 20 non-Salmonella isolates. All Salmonella strains returned positive results, and all non-Salmonella isolates returned a negative response.

  11. Successful Combination of Nucleic Acid Amplification Test Diagnostics and Targeted Deferred Neisseria gonorrhoeae Culture

    PubMed Central

    Wind, Carolien M.; de Vries, Henry J. C.; Schim van der Loeff, Maarten F.; Unemo, Magnus

    2015-01-01

    Nucleic acid amplification tests (NAATs) are recommended for the diagnosis of N. gonorrhoeae infections because of their superior sensitivity. Increasing NAAT use causes a decline in crucial antimicrobial resistance (AMR) surveillance data, which rely on culture. We analyzed the suitability of the ESwab system for NAAT diagnostics and deferred targeted N. gonorrhoeae culture to allow selective and efficient culture based on NAAT results. We included patients visiting the STI Clinic Amsterdam, The Netherlands, in 2013. Patient characteristics and urogenital and rectal samples for direct N. gonorrhoeae culture, standard NAAT, and ESwab were collected. Standard NAAT and NAAT on ESwab samples were performed using the Aptima Combo 2 assay for N. gonorrhoeae and C. trachomatis. Two deferred N. gonorrhoeae cultures were performed on NAAT-positive ESwab samples after storage at 4°C for 1 to 3 days. We included 2,452 samples from 1,893 patients. In the standard NAAT, 107 samples were N. gonorrhoeae positive and 284 were C. trachomatis positive. The sensitivities of NAAT on ESwab samples were 83% (95% confidence interval [CI], 75 to 90%) and 87% (95% CI, 82 to 90%), respectively. ESwab samples were available for 98 of the gonorrhea-positive samples. Of these, 82% were positive in direct culture and 69% and 56% were positive in the 1st and 2nd deferred cultures, respectively (median storage times, 27 and 48 h, respectively). Deferred culture was more often successful in urogenital samples or when the patient had symptoms at the sampling site. Deferred N. gonorrhoeae culture of stored ESwab samples is feasible and enables AMR surveillance. To limit the loss in NAAT sensitivity, we recommend obtaining separate samples for NAAT and deferred culture. PMID:25832300

  12. Status of microbial diversity in agroforestry systems in Tamil Nadu, India.

    PubMed

    Radhakrishnan, Srinivasan; Varadharajan, Mohan

    2016-06-01

    Soil is a complex and dynamic biological system. Agroforestry systems are considered to be an alternative land use option to help and prevent soil degradation, improve soil fertility, microbial diversity, and organic matter status. An increasing interest has emerged with respect to the importance of microbial diversity in soil habitats. The present study deals with the status of microbial diversity in agroforestry systems in Tamil Nadu. Eight soil samples were collected from different fields in agroforestry systems in Cuddalore, Villupuram, Tiruvanamalai, and Erode districts, Tamil Nadu. The number of microorganisms and physico-chemical parameters of soils were quantified. Among different microbial population, the bacterial population was recorded maximum (64%), followed by actinomycetes (23%) and fungi (13%) in different samples screened. It is interesting to note that the microbial population was positively correlated with the physico-chemical properties of different soil samples screened. Total bacterial count had positive correlation with soil organic carbon (C), moisture content, pH, nitrogen (N), and micronutrients such as Iron (Fe), copper (Cu), and zinc (Zn). Similarly, the total actinomycete count also showed positive correlations with bulk density, moisture content, pH, C, N, phosphorus (P), potassium (K), calcium (Ca), copper (Cu), magnesium (Mg), manganese (Mn), and zinc (Zn). It was also noticed that the soil organic matter, vegetation, and soil nutrients altered the microbial community under agroforestry systems. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Improved sample manipulation at the STRESS-SPEC neutron diffractometer using an industrial 6-axis robot for texture and strain analyses

    NASA Astrophysics Data System (ADS)

    Randau, C.; Brokmeier, H. G.; Gan, W. M.; Hofmann, M.; Voeller, M.; Tekouo, W.; Al-hamdany, N.; Seidl, G.; Schreyer, A.

    2015-09-01

    The materials science neutron diffractometer STRESS-SPEC located at FRM II is a dedicated instrument for strain and pole figure measurements. Both methods make complementary demands on sample handling. On one hand pole figure measurements need a high degree of freedom to orient small samples and on the other hand in strain investigations it is often necessary to handle large and heavy components. Therefore a robot based sample positioning system was developed, which has the capability to provide both possibilities. Based on this new robot system further developments like a full automated sample changer system for texture measurements were accomplished. Moreover this system opens the door for combined strain and texture analysis at STRESS-SPEC.

  14. Six degree of freedom fine motion positioning stage based on magnetic levitation

    NASA Technical Reports Server (NTRS)

    Arling, R. W.; Kohler, S. M.

    1994-01-01

    The design of a magnetically suspended six degree of freedom positioning system capable of nanometer positioning is presented. The sample holder is controlled in six degrees of freedom (DOF) over 300 micrometers of travel in the X, Y, and Z directions. A design and control summary and test results indicating stability and power dissipation are included in the paper. The system is vacuum compatible, uses commercially available materials, and requires minimal assembly and setup.

  15. Accuracy of BRT and Delvotest microbial inhibition tests as affected by composition of ewe's milk.

    PubMed

    Althaus, Rafael; Torres, Antonio; Peris, Cristofol; Beltran, M Carmen; Fernandez, Nemesio; Molina, M Pilar

    2003-03-01

    The presence of drug residues in ewe's milk samples can be determined by microbial assays. The main limitation of these tests is the large number of false-positive results associated with them. False-positive results can be explained by the interaction of certain substances naturally existing in ewe's milk with the growth of the microorganism used in the test. In this study, milk chemical composition (fat, protein, lactose, total solids), somatic cell counts (SCCs), free fatty acid concentrations, and lactoperoxidase system components were determined in order to investigate their influence on the rate of false-positive results for the BRT and Delvotest microbiological inhibitor tests. Milk samples were obtained after morning milking of Manchega ewes at 15, 30, 45, 60, 75, 90, 105, 120, and 135 days after parturition. The animals did not receive any kind of treatment or medicated feed throughout the experiment. The false-positive rates for BRT and Delvotest were 3.75 and 2.4%, respectively. When the logistic regression model was applied, the percentages of total solids for positive samples were significantly different from those for negative samples (16.90 versus 18.42% for BRT, 16.05 versus 18.45% for Delvotest), while the SCC logarithmic transformation was significantly higher for the positive samples than for the negative samples (5.38 versus 5.11 log units for BRT, 5.32 versus 5.11 log units for Delvotest). Moreover, Delvotest-positive samples exhibited thiocyanate concentrations higher than those of Delvotest-negative samples (8.18 mg/liter versus 6.85 mg/liter). Further analyses are needed to confirm the possible presence of antimicrobial residues in this particular type of milk sample.

  16. Real-time PCR assay for the detection and quantification of Legionella pneumophila in environmental water samples: utility for daily practice.

    PubMed

    Morio, Florent; Corvec, Stéphane; Caroff, Nathalie; Le Gallou, Florence; Drugeon, Henri; Reynaud, Alain

    2008-07-01

    We developed a quantitative real-time PCR assay targeting the mip gene of Legionella pneumophila for a prospective study from September 2004 to April 2005. It was compared with a standard culture method (French guideline AFNOR T90-431), analysing 120 water samples collected to monitor the risk related to Legionellae at Nantes hospital and to investigate a case of legionellosis acquired from hospital environment. Samples from six distinct water distribution systems were analysed by DNA extraction, amplification and detection with specific primers and FRET probes. The detection limit was 100 genomic units of L. pneumophila per liter (GU/l), the positivity threshold about 600 GU/l and the quantification limit 800 GU/l. PCR results were divided into three groups: negative (n=63), positive but non-quantifiable (n=22) or positive (n=35). PCR showed higher sensitivity than culture, whereas four culture-positive samples appeared negative by PCR (PCR inhibitor detected for two of them). Although no correlation was observed between both methods and real-time PCR cannot substitute for the reference method, it represents an interesting complement. Its sensitivity, reproducibility and rapidity appear particularly interesting in epidemic contexts in order to identify the source of contamination or to evaluate critical points of contamination in water distribution systems.

  17. Improvement of Gynecological Screening of Female Renal Transplant Recipients by Self-Sampling for Human Papillomavirus Detection.

    PubMed

    Hinten, Floor; Hilbrands, Luuk B; Meeuwis, Kim A; van Bergen-Verkuyten, Muriël C; Slangen, Brigitte F; van Rossum, Michelle M; Rahamat-Langendoen, Janette; Massuger, Leon F; de Hullu, Joanne A; Melchers, Willem J

    2017-01-01

    Female renal transplant recipients (RTRs) have increased risk for developing human papillomavirus (HPV)-related (pre)malignancies of the lower genital tract. Annual cervical screening is advised for RTRs, but the participation rate is low. The aim of this study is to investigate whether HPV self-sampling is suitable for gynecological screening of RTRs to increase participation rate. A large cohort of 253 RTRs was investigated for the prevalence of HPV. All participants received a device for a cervicovaginal self-sample. Questionnaires were sent to assess the experience with this device. High-risk (hrHPV) presence was determined with the SPF10-LiPA25 system and GP5+/6+ PCR. HrHPV-positive patients underwent gynecological examination. More than 90% of the patients rated their experience with the self-sample device as good to excellent, and 77% preferred self-sampling over a physician taken sample. Approximately thirty-five of 217 women tested hrHPV positive with SPF10- LiPA25, and 22 tested positive with the GP5+/6+ PCR. Eleven hrHPV-positive patients had clinically relevant gynecological abnormalities, and they all tested positive with GP5+/6+ PCR. Self-sampling is clinically applicable in a gynecological screening and is preferred by female RTRs. Therefore, self-sampling could be implemented with the aim to increase the participation rate of female RTRs in yearly gynecological screening.

  18. Development and testing of a portable wind sensitive directional air sampler

    NASA Technical Reports Server (NTRS)

    Deyo, J.; Toma, J.; King, R. B.

    1975-01-01

    A portable wind sensitive directional air sampler was developed as part of an air pollution source identification system. The system is designed to identify sources of air pollution based on the directional collection of field air samples and their analysis for TSP and trace element characteristics. Sources can be identified by analyzing the data on the basis of pattern recognition concepts. The unit, designated Air Scout, receives wind direction signals from an associated wind vane. Air samples are collected on filter slides using a standard high volume air sampler drawing air through a porting arrangement which tracks the wind direction and permits collection of discrete samples. A preset timer controls the length of time each filter is in the sampling position. At the conclusion of the sampling period a new filter is automatically moved into sampling position displacing the previous filter to a storage compartment. Thus the Air Scout may be set up at a field location, loaded with up to 12 filter slides, and left to acquire air samples automatically, according to the wind, at any timer interval desired from 1 to 30 hours.

  19. Ion-induced electron emission microscopy

    DOEpatents

    Doyle, Barney L.; Vizkelethy, Gyorgy; Weller, Robert A.

    2001-01-01

    An ion beam analysis system that creates multidimensional maps of the effects of high energy ions from an unfocussed source upon a sample by correlating the exact entry point of an ion into a sample by projection imaging of the secondary electrons emitted at that point with a signal from a detector that measures the interaction of that ion within the sample. The emitted secondary electrons are collected in a strong electric field perpendicular to the sample surface and (optionally) projected and refocused by the electron lenses found in a photon emission electron microscope, amplified by microchannel plates and then their exact position is sensed by a very sensitive X Y position detector. Position signals from this secondary electron detector are then correlated in time with nuclear, atomic or electrical effects, including the malfunction of digital circuits, detected within the sample that were caused by the individual ion that created these secondary electrons in the fit place.

  20. Positional calibration of an ultrasound image-guided robotic breast biopsy system.

    PubMed

    Nelson, Thomas R; Tran, Amy; Fakourfar, Hourieh; Nebeker, Jakob

    2012-03-01

    Precision biopsy of small lesions is essential in providing high-quality patient diagnosis and management. Localization depends on high-quality imaging. We have developed a dedicated, fully automatic volume breast ultrasound (US) imaging system for early breast cancer detection. This work focuses on development of an image-guided robotic biopsy system that is integrated with the volume breast US system for performing minimally invasive breast biopsies. The objective of this work was to assess the positional accuracy of the robotic system for breast biopsy. We have adapted a compact robotic arm for performing breast biopsy. The arm incorporates a force torque sensor and is modified to accommodate breast biopsy sampling needles mounted on the robot end effector. Volume breast US images are used as input to a targeting algorithm that provides the physician with control of biopsy device guidance and trajectory optimization. In this work, the positional accuracy was evaluated using (1) a light-emitting diode (LED) mounted on the end effector and (2) a LED mounted on the end of a biopsy needle, each of which was imaged for each robot controller position as part of mapping the positional accuracy throughout a volume that would contain the breast. We measured the error in each location and the cumulative error. Robotic device performance over the volume provided mean accuracy ± SD of 0.76 ± 0.13 mm (end effector) and 0.55 ± 0.13 mm (needle sample location), sufficient for a targeting accuracy within ±1 mm, which is suitable for clinical use. Depth positioning error also was small: 0.38 ± 0.03 mm. Reproducibility was excellent with less than 0.5% variation. Overall accuracy and reproducibility of the compact robotic device were excellent, well within clinical biopsy performance requirements. Volume breast US data provide high-quality input to a biopsy sampling algorithm under physician control. Robotic devices may provide more precise device placement, assisting physicians with biopsy procedures.

  1. Accuracy Analysis of a Wireless Indoor Positioning System Using Geodetic Methods

    NASA Astrophysics Data System (ADS)

    Wagner, Przemysław; Woźniak, Marek; Odziemczyk, Waldemar; Pakuła, Dariusz

    2017-12-01

    Ubisense RTLS is one of the Indoor positioning systems using an Ultra Wide Band. AOA and TDOA methods are used as a principle of positioning. The accuracy of positioning depends primarily on the accuracy of determined angles and distance differences. The paper presents the results of accuracy research which includes a theoretical accuracy prediction and a practical test. Theoretical accuracy was calculated for two variants of system components geometry, assuming the parameters declared by the system manufacturer. Total station measurements were taken as a reference during the practical test. The results of the analysis are presented in a graphical form. A sample implementation (MagMaster) developed by Globema is presented in the final part of the paper.

  2. Accurate mobile malware detection and classification in the cloud.

    PubMed

    Wang, Xiaolei; Yang, Yuexiang; Zeng, Yingzhi

    2015-01-01

    As the dominator of the Smartphone operating system market, consequently android has attracted the attention of s malware authors and researcher alike. The number of types of android malware is increasing rapidly regardless of the considerable number of proposed malware analysis systems. In this paper, by taking advantages of low false-positive rate of misuse detection and the ability of anomaly detection to detect zero-day malware, we propose a novel hybrid detection system based on a new open-source framework CuckooDroid, which enables the use of Cuckoo Sandbox's features to analyze Android malware through dynamic and static analysis. Our proposed system mainly consists of two parts: anomaly detection engine performing abnormal apps detection through dynamic analysis; signature detection engine performing known malware detection and classification with the combination of static and dynamic analysis. We evaluate our system using 5560 malware samples and 6000 benign samples. Experiments show that our anomaly detection engine with dynamic analysis is capable of detecting zero-day malware with a low false negative rate (1.16 %) and acceptable false positive rate (1.30 %); it is worth noting that our signature detection engine with hybrid analysis can accurately classify malware samples with an average positive rate 98.94 %. Considering the intensive computing resources required by the static and dynamic analysis, our proposed detection system should be deployed off-device, such as in the Cloud. The app store markets and the ordinary users can access our detection system for malware detection through cloud service.

  3. [Application of transcription mediated amplification and real-time reverse transcription polymerase chain reaction in detection of human immunodeficiency virus RNA].

    PubMed

    Wu, Daxian; Tao, Shuhui; Liu, Shuiping; Zhou, Jiebin; Tan, Deming; Hou, Zhouhua

    2017-07-28

    To observe the sensitivity of transcription mediated amplification (TMA), and to compare its performance with real-time reverse transcription polymerase chain reaction (real-time RT-PCR) in detecting human immunodeficiency virus RNA (HIV RNA).
 Methods: TMA system was established with TaqMan probes, specific primers, moloney murine leukemia virus (MMLV) reverse transcriptase, T7 RNA polymerase, and reaction substrates. The sensitivity of TMA was evaluated by amplifying a group of 10-fold diluted HIV RNA standards which were transcribed in vitro. A total of 60 plasma of HIV infected patients were measured by TMA and Cobas Amplicor HIV-1 Monitor test to observe the positive rate. The correlation and concordance of the above two technologies were investigated by linear regression and Bland-Altman analysis.
 Results: TMA system was established successfully and HIV RNA transcribed standards at concentration of equal or more than 10 copies/mL could be detected by TMA technology. Among 60 samples of plasma from HIV infected patients, 46 were positively detected and 12 were negatively amplified by both TMA and Cobas reagents; 2 samples were positively tested by Cobas reagent but negatively tested by TMA system. The concordance rate of the two methods was 97.1% and the difference of positive detection rate between the two methods was not statistically significant (P>0.05). Linear regression was used for 46 samples which were positively detected by both TMA and Cobas reagents and showed an excellent correlation between the two reagents (r=0.997, P<0.001). Bland-Altma analysis revealed that the mean different value of HIV RNA levels for denary logarithm was 0.02. Forty-four samples were included in 95% of credibility interval of concordance.
 Conclusion: TMA system has the potential of high sensitivity. TMA and real-time RT-PCR keep an excellent correlation and consistency in detecting HIV RNA.

  4. Antibody against infectious salmon anaemia virus among feral Atlantic salmon (Salmo salar)

    USGS Publications Warehouse

    Cipriano, R.C.

    2009-01-01

    Archived sera from Atlantic salmon (Salmo salar) that returned to the Penobscot River (Maine), Merrimack River (Massachusetts), and Connecticut River (in Massachusetts) from 1995 to 2002 were analysed for antibodies against infectious salmon anaemia virus (ISAV) using an enzyme-linked immunosorbent assay (ELISA). Up to 60 samples were archived per river system per year. In a given year, the number of fish sampled by ELISA for ISAV antibodies in the Penobscot River ranged from 2.9 to 11.2, and the range of salmon sampled in the Merrimack River and the Connecticut River was 31.3-100 and 20.0-67.5, respectively. Archived sera were not available for the 1995 and 2002 year classes from the Connecticut River. In all, 1141 samples were processed; 14 serum samples tested positive for antibodies to ISAV. In the Penobscot River, serum from one fish tested positive in each of the 1995 and 1999 year-class returns, and sera from two fish tested positive in the 1998 returns. In the Merrimack River, sera from four fish tested positive in each of the 1996 and 1997 returns, and sera from two fish were positive in the 2002 return. None of the archived sera from Atlantic salmon that returned to the Connecticut River tested positive. ?? 2009 United States Government, Department of the Interior.

  5. Reevaluation of confirmatory tests for human T-cell leukemia virus Type 1 using a luciferase immunoprecipitation system in blood donors.

    PubMed

    Furuta, Rika A; Ma, Guangyong; Matsuoka, Masao; Otani, Satoshi; Matsukura, Harumichi; Hirayama, Fumiya

    2015-04-01

    Recently, Japanese Red Cross blood centers have changed the confirmatory test method from an indirect immunofluorescence (IF) technique to Western blotting (WB) for antibodies against human T-cell leukemia virus Type 1 (HTLV-1). In this study, these HTLV-1 tests were assessed using another sensitive method, that is, a luciferase immunoprecipitation system (LIPS), to identify a better confirmatory test for HTLV-1 infection. Plasma samples from 54 qualified donors and 114 HTLV-1 screening-positive donors were tested by LIPS for antibodies against HTLV-1 Gag, Tax, Env, and HBZ recombinant proteins. The donors were categorized into six groups, namely, (Group I) qualified donors, screening positive; (Group II) IF positive; (Group III) IF negative; (Group IV) WB positive; (Group V) WB negative; and (Group VI) screening positive in the previous blood donation, but WB-indeterminate during this study period. In Groups II and IV, all plasma samples tested positive by LIPS for antibodies against Gag and Env proteins. In Group V, all samples tested negative by LIPS, whereas some Group III samples reacted with single or double antigens in LIPS. In Group VI, the LIPS test identified a donor with suspected HTLV-1 infection. The first case of a blood donor with plasma that reacted with HBZ was identified by LIPS. Reevaluation of the current HTLV-1 screening method using the LIPS test showed that both confirmatory tests had similar sensitivity and specificity only when WB indeterminate results were eliminated. LIPS is a promising method for detecting and characterizing HTLV-1 antibodies. © 2014 AABB.

  6. RaPToRS Sample Delivery System

    NASA Astrophysics Data System (ADS)

    Henchen, Robert; Shibata, Kye; Krieger, Michael; Pogozelski, Edward; Padalino, Stephen; Glebov, Vladimir; Sangster, Craig

    2010-11-01

    At various labs (NIF, LLE, NRL), activated material samples are used to measure reaction properties. The Rapid Pneumatic Transport of Radioactive Samples (RaPToRS) system quickly and safely moves these radioactive samples through a closed PVC tube via airflow. The carrier travels from the reaction chamber to the control and analysis station, pneumatically braking at the outlet. A reversible multiplexer routes samples from various locations near the shot chamber to the analysis station. Also, the multiplexer allows users to remotely load unactivated samples without manually approaching the reaction chamber. All elements of the system (pneumatic drivers, flow control valves, optical position sensors, multiplexers, Geiger counters, and release gates at the analysis station) can be controlled manually or automatically using a custom LabVIEW interface. A prototype is currently operating at NRL in Washington DC. Prospective facilities for Raptors systems include LLE and NIF.

  7. Contrastive Analysis and Research on Negative Pressure Beam Tube System and Positive Pressure Beam Tube System for Mine Use

    NASA Astrophysics Data System (ADS)

    Wang, Xinyi; Shen, Jialong; Liu, Xinbo

    2018-01-01

    Against the technical defects of universally applicable beam tube monitoring system at present, such as air suction in the beam tube, line clogging, long sampling time, etc., the paper analyzes the current situation of the spontaneous combustion fire disaster forecast of mine in our country and these defects one by one. On this basis, the paper proposes a research thought that improving the positive pressure beam tube so as to substitute the negative pressure beam tube. Then, the paper introduces the beam tube monitoring system based on positive pressure technology through theoretical analysis and experiment. In the comparison with negative pressure beam tube, the paper concludes the advantage of the new system and draws the conclusion that the positive pressure beam tube is superior to the negative pressure beam tube system both in test result and test time. At last, the paper proposes prospect of the beam tube monitoring system based on positive pressure technology.

  8. Association between weight and risk of crash-related injuries for children in child restraints.

    PubMed

    Zonfrillo, Mark R; Elliott, Michael R; Flannagan, Carol A; Durbin, Dennis R

    2011-12-01

    To determine the association between weight and the risk of injury in motor vehicle crashes (MVCs) for children 1 through 8 years of age who were using child restraints. This was a cross-sectional study of children 1 to 8 years of age in MVCs, in which cases from the National Automotive Sampling System Crashworthiness Data System were used. Abbreviated Injury Scale scores of ≥2 indicated clinically significant injuries. The National Automotive Sampling System Crashworthiness Data System study sample included 650 children 1 to 5 years of age in forward-facing child restraints who weighed 20 to 65 lb and 344 children 3 to 8 years of age in belt-positioning booster seats who weighed 30 to 100 lb. With adjustment for seating position, type of vehicle, direction of impact, crash severity, and vehicle model year, there was no association between absolute weight and clinically significant injuries in either age group (odds ratio: 1.17 [95% confidence interval: 0.96-1.42] for children 1-5 years of age in forward-facing child restraints and 1.22 [95% confidence interval: 0.96-1.55] for children 3-8 years of age in belt-positioning booster seats). The risk of clinically significant injuries was not associated with weight across a broad weight range in this sample of children in MVCs who were using child restraint systems. Parents should continue to restrain their children according to current recommendations from the American Academy of Pediatrics and the National Highway Traffic Safety Administration.

  9. Performance of a completely automated system for monitoring CMV DNA in plasma.

    PubMed

    Mengelle, C; Sandres-Sauné, K; Mansuy, J-M; Haslé, C; Boineau, J; Izopet, J

    2016-06-01

    Completely automated systems for monitoring CMV-DNA in plasma samples are now available. Evaluate analytical and clinical performances of the VERIS™/MDx System CMV Assay(®). Analytical performance was assessed using quantified quality controls. Clinical performance was assessed by comparison with the COBAS(®) Ampliprep™/COBAS(®) Taqman CMV test using 169 plasma samples that had tested positive with the in-house technique in whole blood. The specificity of the VERIS™/MDx System CMV Assay(®) was 99% [CI 95%: 97.7-100]. Intra-assay reproducibilities were 0.03, 0.04, 0.05 and 0.04 log10IU/ml (means 2.78, 3.70, 4.64 and 5.60 log10IU/ml) for expected values of 2.70, 3.70, 4.70 and 5.70 log10IU/ml. The inter-assay reproducibilities were 0.12 and 0.08 (means 6.30 and 2.85 log10IU/ml) for expected values of 6.28 and 2.80 log10IU/ml. The lower limit of detection was 14.6IU/ml, and the assay was linear from 2.34 to 5.58 log10IU/ml. The results for the positive samples were concordant (r=0.71, p<0.0001; slope of Deming regression 0.79 [CI 95%: 0.56-1.57] and y-intercept 0.79 [CI 95%: 0.63-0.95]). The VERIS™/MDx System CMV Assay(®) detected 18 more positive samples than did the COBAS(®) Ampliprep™/COBAS(®) Taqman CMV test and the mean virus load were higher (0.41 log10IU/ml). Patient monitoring on 68 samples collected from 17 immunosuppressed patients showed similar trends between the two assays. As secondary question, virus loads detected by the VERIS™/MDx System CMV Assay(®) were compared to those of the in-house procedure on whole blood. The results were similar between the two assays (-0.09 log10IU/ml) as were the patient monitoring trends. The performances of the VERIS™/MDx System CMV Assay(®) facilitated its routine use in monitoring CMV-DNA loads in plasma samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Evaluation of EMIT and RIA high volume test procedures for THC metabolites in urine utilizing GC/MS confirmation.

    PubMed

    Abercrombie, M L; Jewell, J S

    1986-01-01

    Results of EMIT, Abuscreen RIA, and GC/MS tests for THC metabolites in a high volume random urinalysis program are compared. Samples were field tested by non-laboratory personnel with an EMIT system using a 100 ng/mL cutoff. Samples were then sent to the Army Forensic Toxicology Drug Testing Laboratory (WRAMC) at Fort Meade, Maryland, where they were tested by RIA (Abuscreen) using a statistical 100 ng/mL cutoff. Confirmations of all RIA positives were accomplished using a GC/MS procedure. EMIT and RIA results agreed for 91% of samples. Data indicated a 4% false positive rate and a 10% false negative rate for EMIT field testing. In a related study, results for samples which tested positive by RIA for THC metabolites using a statistical 100 ng/mL cutoff were compared with results by GC/MS utilizing a 20 ng/mL cutoff for the THCA metabolite. Presence of THCA metabolite was detected in 99.7% of RIA positive samples. No relationship between quantitations determined by the two tests was found.

  11. Same-Day Identification and Antimicrobial Susceptibility Testing of Bacteria in Positive Blood Culture Broths Using Short-Term Incubation on Solid Medium with the MicroFlex LT, Vitek-MS, and Vitek2 Systems

    PubMed Central

    Ha, Jihye; Han, Geum Hee; Kim, Myungsook; Lee, Kyungwon

    2018-01-01

    Background Early and appropriate antibiotic treatment improves the clinical outcome of patients with septicemia; therefore, reducing the turn-around time for identification (ID) and antimicrobial susceptibility test (AST) results is essential. We established a method for rapid ID and AST using short-term incubation of positive blood culture broth samples on solid media, and evaluated its performance relative to that of the conventional method using two rapid ID systems and a rapid AST method. Methods A total of 254 mono-microbial samples were included. Positive blood culture samples were incubated on blood agar plates for six hours and identified by the MicroFlex LT (Bruker Daltonics) and Vitek-MS (bioMeriéux) systems, followed by AST using the Vitek2 System (bioMeriéux). Results The correct species-level ID rates were 82.3% (209/254) and 78.3% (199/254) for the MicroFlex LT and Vitek-MS platforms, respectively. For the 1,174 microorganism/antimicrobial agent combinations tested, the rapid AST method showed total concordance of 97.8% (1,148/1,174) with the conventional method, with a very major error rate of 0.5%, major error rate of 0.7%, and minor error rate of 1.0%. Conclusions Routine implementation of this short-term incubation method could provide ID results on the day of blood culture-positivity detection and one day earlier than the conventional AST method. This simple method will be very useful for rapid ID and AST of bacteria from positive blood culture bottles in routine clinical practice. PMID:29401558

  12. Same-Day Identification and Antimicrobial Susceptibility Testing of Bacteria in Positive Blood Culture Broths Using Short-Term Incubation on Solid Medium with the MicroFlex LT, Vitek-MS, and Vitek2 Systems.

    PubMed

    Ha, Jihye; Hong, Sung Kuk; Han, Geum Hee; Kim, Myungsook; Yong, Dongeun; Lee, Kyungwon

    2018-05-01

    Early and appropriate antibiotic treatment improves the clinical outcome of patients with septicemia; therefore, reducing the turn-around time for identification (ID) and antimicrobial susceptibility test (AST) results is essential. We established a method for rapid ID and AST using short-term incubation of positive blood culture broth samples on solid media, and evaluated its performance relative to that of the conventional method using two rapid ID systems and a rapid AST method. A total of 254 mono-microbial samples were included. Positive blood culture samples were incubated on blood agar plates for six hours and identified by the MicroFlex LT (Bruker Daltonics) and Vitek-MS (bioMeriéux) systems, followed by AST using the Vitek2 System (bioMeriéux). The correct species-level ID rates were 82.3% (209/254) and 78.3% (199/254) for the MicroFlex LT and Vitek-MS platforms, respectively. For the 1,174 microorganism/antimicrobial agent combinations tested, the rapid AST method showed total concordance of 97.8% (1,148/1,174) with the conventional method, with a very major error rate of 0.5%, major error rate of 0.7%, and minor error rate of 1.0%. Routine implementation of this short-term incubation method could provide ID results on the day of blood culture-positivity detection and one day earlier than the conventional AST method. This simple method will be very useful for rapid ID and AST of bacteria from positive blood culture bottles in routine clinical practice. © The Korean Society for Laboratory Medicine

  13. A DNA pooling based system to detect Escherichia coli virulence factors in fecal and wastewater samples

    PubMed Central

    Luz María Chacón, J; Lizeth Taylor, C; Carmen Valiente, A; Irene Alvarado, P; Ximena Cortés, B

    2012-01-01

    The availability of a useful tool for simple and timely detection of the most important virulent varieties of Escherichia coli is indispensable. To this end, bacterial DNA pools which had previously been categorized were obtained from isolated colonies as well as selected in terms of utilized phenotype; the pools were assessed by two PCR Multiplex for the detection of virulent E. coli eaeA, bfpA, stx1, stx2, ipaH, ST, LT, and aatA genes, with the 16S gene used as DNA control. The system was validated with 66 fecal samples and 44 wastewater samples. At least one positive isolate was detected by a virulent gene among the 20 that were screened. The analysis of fecal samples from children younger than 6 years of age detected frequencies of 25% LT positive strains, 8.3% eae, 8.3% bfpA, 16.7% ipaH, as well as 12.5 % aatA and ST. On the other hand, wastewater samples revealed frequencies of 25.7% eaeA positive, 30.3% stx1, 15.1% LT and 19.7% aatA. This study is an initial step toward carrying out epidemiological field research that will reveal the presence of these bacterial varieties. PMID:24031959

  14. Automated paleomagnetic and rock magnetic data acquisition with an in-line horizontal "2G" system

    NASA Astrophysics Data System (ADS)

    Mullender, Tom A. T.; Frederichs, Thomas; Hilgenfeldt, Christian; de Groot, Lennart V.; Fabian, Karl; Dekkers, Mark J.

    2016-09-01

    Today's paleomagnetic and magnetic proxy studies involve processing of large sample collections while simultaneously demanding high quality data and high reproducibility. Here we describe a fully automated interface based on a commercial horizontal pass-through "2G" DC-SQUID magnetometer. This system is operational at the universities of Bremen (Germany) and Utrecht (Netherlands) since 1998 and 2006, respectively, while a system is currently being built at NGU Trondheim (Norway). The magnetometers are equipped with "in-line" alternating field (AF) demagnetization, a direct-current bias field coil along the coaxial AF demagnetization coil for the acquisition of anhysteretic remanent magnetization (ARM) and a long pulse-field coil for the acquisition of isothermal remanent magnetization (IRM). Samples are contained in dedicated low magnetization perspex holders that are manipulated by a pneumatic pick-and-place-unit. Upon desire samples can be measured in several positions considerably enhancing data quality in particular for magnetically weak samples. In the Bremen system, the peak of the IRM pulse fields is actively measured which reduces the discrepancy between the set field and the field that is actually applied. Techniques for quantifying and removing gyroremanent overprints and for measuring the viscosity of IRM further extend the range of applications of the system. Typically c. 300 paleomagnetic samples can be AF demagnetized per week (15 levels) in the three-position protocol. The versatility of the system is illustrated by several examples of paleomagnetic and rock magnetic data processing.

  15. Cost assessment of the automated VERSANT 440 Molecular System versus the semi-automated System 340 bDNA Analyzer platforms.

    PubMed

    Elbeik, Tarek; Loftus, Richard A; Beringer, Scott

    2007-11-01

    Labor, supply and waste were evaluated for HIV-1 and HCV bDNA on the semi-automated System 340 bDNA Analyzer and the automated VERSANT 440 Molecular System (V440). HIV-1 sample processing was evaluated using a 24- and 48-position centrifuge rotor. Vigilance time (hands-on manipulations plus incubation time except initial target hybridization) and disposables were approximately 37 and 12% lower for HIV-1, and 64 and 31% lower for HCV bDNA, respectively, with V440. Biohazardous solid waste was approximately twofold lower for both assays and other waste types were the same for either assay on both platforms. HIV-1 sample processing vigilance time for the 48-position rotor was reduced by 2 h. V440 provides cost savings and improved workflow.

  16. Imaging, Sensing, And Communication Through Highly Scattering Complex Media

    DTIC Science & Technology

    2015-11-24

    lithography systems create the essential components of our computers and smartphones, which themselves contain ever more advanced optical systems that...the phase coherence of the light, scattered waves that arrive by ‘different paths’ through the sample show interference . Depending on the detailed...positions of the random scatterers, this interference is constructive at some positions and destructive at others. The result is a characteristic

  17. Infrared (IR) photon-sensitive spectromicroscopy in a cryogenic environment

    DOEpatents

    Pereverzev, Sergey

    2016-06-14

    A system designed to suppress thermal radiation background and to allow IR single-photon sensitive spectromicroscopy of small samples by using both absorption, reflection, and emission/luminescence measurements. The system in one embodiment includes: a light source; a plurality of cold mirrors configured to direct light along a beam path; a cold or warm sample holder in the beam path; windows of sample holder (or whole sample holder) are transparent in a spectral region of interest, so they do not emit thermal radiation in the same spectral region of interest; a cold monochromator or other cold spectral device configured to direct a selected fraction of light onto a cold detector; a system of cold apertures and shields positioned along the beam path to prevent unwanted thermal radiation from arriving at the cold monochromator and/or the detector; a plurality of optical, IR and microwave filters positioned along the beam path and configured to adjust a spectral composition of light incident upon the sample under investigation and/or on the detector; a refrigerator configured to maintain the detector at a temperature below 1.0K; and an enclosure configured to: thermally insulate the light source, the plurality of mirrors, the sample holder, the cold monochromator and the refrigerator.

  18. A passivity criterion for sampled-data bilateral teleoperation systems.

    PubMed

    Jazayeri, Ali; Tavakoli, Mahdi

    2013-01-01

    A teleoperation system consists of a teleoperator, a human operator, and a remote environment. Conditions involving system and controller parameters that ensure the teleoperator passivity can serve as control design guidelines to attain maximum teleoperation transparency while maintaining system stability. In this paper, sufficient conditions for teleoperator passivity are derived for when position error-based controllers are implemented in discrete-time. This new analysis is necessary because discretization causes energy leaks and does not necessarily preserve the passivity of the system. The proposed criterion for sampled-data teleoperator passivity imposes lower bounds on the teleoperator's robots dampings, an upper bound on the sampling time, and bounds on the control gains. The criterion is verified through simulations and experiments.

  19. Acoustic Translation of an Acoustically Levitated Sample

    NASA Technical Reports Server (NTRS)

    Barmatz, M. B.; Allen, J. L.

    1986-01-01

    Acoustic-levitation apparatus uses only one acoustic mode to move sample from one region of chamber to another. Sample heated and cooled quickly by translation between hot and cold regions of levitation chamber. Levitated sample is raised into furnace region by raising plunger. Frequency of sound produced by transducers adjusted by feedback system to maintain (102) resonant mode, which levitates sample midway between transducers and plunger regardless of plunger position.

  20. Evaluation of PMS-PCR technology for detection of Mycobacterium avium subsp. paratuberculosis directly from bovine fecal specimens.

    PubMed

    Salgado, M; Steuer, P; Troncoso, E; Collins, M T

    2013-12-27

    Mycobacterium avium subsp. paratuberculosis (MAP) causes paratuberculosis, or Johne's disease, in animals. Diagnosis of MAP infection is challenging because of the pathogen's fastidious in vitro growth requirements and low-level intermittent shedding in feces during the preclinical phase of the infection. Detection of these "low-shedders" is important for effective control of paratuberculosis as these animals serve as sources of infection for susceptible calves. Magnetic separation technology, used in combination with culture or molecular methods for the isolation and detection of pathogenic bacteria, enhances the analytical sensitivity and specificity of detection methods. The aim of the present study was to evaluate peptide-mediated magnetic separation (PMS) capture technology coupled with IS900 PCR using the Roche real-time PCR system (PMS-PCR), in comparison with fecal culture using BACTEC-MGIT 960 system, for detection of MAP in bovine fecal samples. Among the 351 fecal samples 74.9% (263/351) were PMS-PCR positive while only 12.3% (43/351) were MGIT culture-positive (p=0.0001). All 43 MGIT culture-positive samples were also positive by PMS-PCR. Mean PMS-PCR crossing-point (Cp) values for the 13 fecal samples with the highest number of MAP, based on time to detection, (26.3) were significantly lower than for the 17 fecal samples with <100 MAP per 2g feces (30.06) (p<0.05). PMS-PCR technology provided results in a shorter time and yielded a higher number of positive results than MGIT culture. Earlier and faster detection of animals shedding MAP by PMS-PCR should significantly strengthen control efforts for MAP-infected cattle herds by helping to limit infection transmission at earlier stages of the infection. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Optimal approaches for inline sampling of organisms in ballast water: L-shaped vs. Straight sample probes

    NASA Astrophysics Data System (ADS)

    Wier, Timothy P.; Moser, Cameron S.; Grant, Jonathan F.; Riley, Scott C.; Robbins-Wamsley, Stephanie H.; First, Matthew R.; Drake, Lisa A.

    2017-10-01

    Both L-shaped ("L") and straight ("Straight") sample probes have been used to collect water samples from a main ballast line in land-based or shipboard verification testing of ballast water management systems (BWMS). A series of experiments was conducted to quantify and compare the sampling efficiencies of L and Straight sample probes. The findings from this research-that both L and Straight probes sample organisms with similar efficiencies-permit increased flexibility for positioning sample probes aboard ships.

  2. Widespread Environmental Contamination with Mycobacterium tuberculosis Complex Revealed by a Molecular Detection Protocol

    PubMed Central

    Santos, Nuno; Santos, Catarina; Valente, Teresa; Gortázar, Christian; Almeida, Virgílio; Correia-Neves, Margarida

    2015-01-01

    Environmental contamination with Mycobacterium tuberculosis complex (MTC) has been considered crucial for bovine tuberculosis persistence in multi-host-pathogen systems. However, MTC contamination has been difficult to detect due to methodological issues. In an attempt to overcome this limitation we developed an improved protocol for the detection of MTC DNA. MTC DNA concentration was estimated by the Most Probable Number (MPN) method. Making use of this protocol we showed that MTC contamination is widespread in different types of environmental samples from the Iberian Peninsula, which supports indirect transmission as a contributing mechanism for the maintenance of bovine tuberculosis in this multi-host-pathogen system. The proportion of MTC DNA positive samples was higher in the bovine tuberculosis-infected than in presumed negative area (0.32 and 0.18, respectively). Detection varied with the type of environmental sample and was more frequent in sediment from dams and less frequent in water also from dams (0.22 and 0.05, respectively). The proportion of MTC-positive samples was significantly higher in spring (p<0.001), but MTC DNA concentration per sample was higher in autumn and lower in summer. The average MTC DNA concentration in positive samples was 0.82 MPN/g (CI95 0.70–0.98 MPN/g). We were further able to amplify a DNA sequence specific of Mycobacterium bovis/caprae in 4 environmental samples from the bTB-infected area. PMID:26561038

  3. Fuzzy logic control system to provide autonomous collision avoidance for Mars rover vehicle

    NASA Technical Reports Server (NTRS)

    Murphy, Michael G.

    1990-01-01

    NASA is currently involved with planning unmanned missions to Mars to investigate the terrain and process soil samples in advance of a manned mission. A key issue involved in unmanned surface exploration on Mars is that of supporting autonomous maneuvering since radio communication involves lengthy delays. It is anticipated that specific target locations will be designated for sample gathering. In maneuvering autonomously from a starting position to a target position, the rover will need to avoid a variety of obstacles such as boulders or troughs that may block the shortest path to the target. The physical integrity of the rover needs to be maintained while minimizing the time and distance required to attain the target position. Fuzzy logic lends itself well to building reliable control systems that function in the presence of uncertainty or ambiguity. The following major issues are discussed: (1) the nature of fuzzy logic control systems and software tools to implement them; (2) collision avoidance in the presence of fuzzy parameters; and (3) techniques for adaptation in fuzzy logic control systems.

  4. Acoustic Levitation System

    NASA Technical Reports Server (NTRS)

    Gammell, P. M.; Wang, T. G.; Croonquist, A.; Lee, M. C.

    1985-01-01

    Dense materials, such as steel balls, continuously levitated with energy provided by efficient high-powered siren in combination with shaped reflector. Reflector system, consisting of curved top reflector and flat lower reflector, eliminates instability in spatial positioning of sample.

  5. Coordinate interferometric system for measuring the position of a sample with infrared telecom laser diode

    NASA Astrophysics Data System (ADS)

    Holá, Miroslava; Lazar, Josef; Čížek, Martin; Hucl, Václav; Řeřucha, Šimon; Číp, Ondřej

    2016-11-01

    We report on a design of an interferometric position measuring system for control of a sample stage in an e-beam writer with reproducibility of the position on nanometer level and resolution below nanometer. We introduced differential configuration of the interferometer where the position is measured with respect to a central reference point to eliminate deformations caused by thermal and pressure effects on the vacuum chamber. The reference is here the electron gun of the writer. The interferometer is designed to operate at infrared, telecommunication wavelength due to the risk of interference of stray light with sensitive photodetectors in the chamber. The laser source is here a narrow-linewidth DFB laser diode with electronics of our own design offering precision and stability of temperature and current, low-noise, protection from rf interference, and high-frequency modulation. Detection of the interferometric signal relies on a novel derivative technique utilizing hf frequency modulation and phase-sensitive detection.

  6. Automatic position calculating imaging radar with low-cost synthetic aperture sensor for imaging layered media

    DOEpatents

    Mast, J.E.

    1998-08-18

    An imaging system for analyzing structures comprises a radar transmitter and receiver connected to a timing mechanism that allows a radar echo sample to be taken at a variety of delay times for each radar pulse transmission. The radar transmitter and receiver are coupled to a position determining system that provides the x,y position on a surface for each group of samples measured for a volume from the surface. The radar transmitter and receiver are moved about the surface to collect such groups of measurements from a variety of x,y positions. Return signal amplitudes represent the relative reflectivity of objects within the volume and the delay in receiving each signal echo represents the depth at which the object lays in the volume and the propagation speeds of the intervening material layers. Successively deeper z-planes are backward propagated from one layer to the next with an adjustment for variations in the expected propagation velocities of the material layers that lie between adjacent z-planes. 10 figs.

  7. Automatic position calculating imaging radar with low-cost synthetic aperture sensor for imaging layered media

    DOEpatents

    Mast, Jeffrey E.

    1998-01-01

    An imaging system for analyzing structures comprises a radar transmitter and receiver connected to a timing mechanism that allows a radar echo sample to be taken at a variety of delay times for each radar pulse transmission. The radar transmitter and receiver are coupled to a position determining system that provides the x,y position on a surface for each group of samples measured for a volume from the surface. The radar transmitter and receiver are moved about the surface to collect such groups of measurements from a variety of x,y positions. Return signal amplitudes represent the relative reflectivity of objects within the volume and the delay in receiving each signal echo represents the depth at which the object lays in the volume and the propagation speeds of the intervening material layers. Successively deeper z-planes are backward propagated from one layer to the next with an adjustment for variations in the expected propagation velocities of the material layers that lie between adjacent z-planes.

  8. Filtration of water-sediment samples for the determination of organic compounds

    USGS Publications Warehouse

    Sandstrom, Mark W.

    1995-01-01

    This report describes the equipment and procedures used for on-site filtration of surface-water and ground-water samples for determination of organic compounds. Glass-fiber filters and a positive displacement pumping system are suitable for processing most samples for organic analyses. An optional system that uses disposable in-line membrane filters is suitable for a specific gas chromatography/mass spectrometry, selected-ion monitoring analytical method for determination of organonitrogen herbicides. General procedures to minimize contamination of the samples include preparing a clean workspace at the site, selecting appropriate sample-collection materials, and cleaning of the equipment with detergent, tap water, and methanol.

  9. Usefulness of FTA® cards as a Pneumocystis-DNA extraction method in bronchoalveolar lavage samples.

    PubMed

    Rodiño, Jenniffer M; Aguilar, Yudy A; Rueda, Zulma Vanessa; Vélez, Lázaro A

    2016-01-01

    FTA® cards (Fast Technology for Analysis of Nucleic Acids) are an alternative DNA extraction method in bronchoalveolar lavage (BAL) samples for Pneumocystis jirovecii molecular analyses. The goal was to evaluate the usefulness of FTA® cards to detect P. jirovecii-DNA by PCR in BAL samples compared to silica adsorption chromatography (SAC). This study used 134 BAL samples from immunocompromised patients previously studied to establish microbiological aetiology of pneumonia, among them 15 cases of Pneumocystis pneumonia (PCP) documented by staining and 119 with other alternative diagnoses. The FTA® system and SAC were used for DNA extraction and then amplified by nested PCR to detect P. jirovecii. Performance and concordance of the two DNA extraction methods compared to P. jirovecii microscopy were calculated. The influence of the macroscopic characteristics, transportation of samples and the duration of the FTA® card storage (1, 7, 10 or 12 months) were also evaluated. Among 134 BAL samples, 56% were positive for P. jirovecii-DNA by SAC and 27% by FTA®. All 15 diagnosed by microscopy were detected by FTA® and SAC. Specificity of the FTA® system and SAC were 82.4% and 49.6%, respectively. Compared to SAC, positivity by FTA® decreased with the presence of blood in BAL (62% vs 13.5%). The agreement between samples at 7, 10 and 12 months was 92.5% for FTA®. Positive cases by FTA® remained the same after shipment by mail. Results suggest that FTA® is a practical, safe and economical method to preserve P. jirovecii-DNA in BAL samples for molecular studies.

  10. Tamper to delay motion and decrease ionization of a sample during short pulse x-ray imaging

    DOEpatents

    London, Richard A [Orinda, CA; Szoke,; Abraham, Hau-Riege [Fremont, CA; Stefan P. , Chapman; Henry, N [Livermore, CA

    2007-06-26

    A system for x-ray imaging of a small sample comprising positioning a tamper so that it is operatively connected to the sample, directing short intense x-ray pulses onto the tamper and the sample, and detecting an image from the sample. The tamper delays the explosive motion of the sample during irradiation by the short intense x-ray pulses, thereby extending the time to obtain an x-ray image of the original structure of the sample.

  11. Laser heating of aqueous samples on a micro-optical-electro-mechanical system

    DOEpatents

    Beer, Neil Reginald; Kennedy, Ian

    2013-12-17

    A system of heating a sample on a microchip includes the steps of providing a microchannel flow channel in the microchip; positioning the sample within the microchannel flow channel, providing a laser that directs a laser beam onto the sample for heating the sample; providing the microchannel flow channel with a wall section that receives the laser beam and enables the laser beam to pass through wall section of the microchannel flow channel without being appreciably heated by the laser beam; and providing a carrier fluid in the microchannel flow channel that moves the sample in the microchannel flow channel wherein the carrier fluid is not appreciably heated by the laser beam.

  12. Laser heating of aqueous samples on a micro-optical-electro-mechanical system

    DOEpatents

    Beer, Neil Reginald; Kennedy, Ian

    2013-02-05

    A system of heating a sample on a microchip includes the steps of providing a microchannel flow channel in the microchip; positioning the sample within the microchannel flow channel, providing a laser that directs a laser beam onto the sample for heating the sample; providing the microchannel flow channel with a wall section that receives the laser beam and enables the laser beam to pass through wall section of the microchannel flow channel without being appreciably heated by the laser beam; and providing a carrier fluid in the microchannel flow channel that moves the sample in the microchannel flow channel wherein the carrier fluid is not appreciably heated by the laser beam.

  13. Effect of density gradient centrifugation on reactive oxygen species in human semen.

    PubMed

    Takeshima, Teppei; Yumura, Yasushi; Kuroda, Shinnosuke; Kawahara, Takashi; Uemura, Hiroji; Iwasaki, Akira

    2017-06-01

    Density gradient centrifugation can separate motile sperm from immotile sperm and other cells for assisted reproduction, but may also remove antioxidants from seminal plasma, resulting in oxidative stress. Therefore, we investigated reactive oxygen species (ROS) concentrations and distribution in semen before and after density gradient centrifugation. We assessed semen volume, sperm concentration, sperm motility, and ROS levels before and after density gradient centrifugation (300 x g for 20 minutes) in 143 semen samples from 118 patients. The ROS removal rate was evaluated in ROS-positive samples and ROS formation rate in ROS-negative samples. Thirty-eight of 143 untreated samples (26.6%) were ROS-positive; sperm motility was significantly lower in these samples than in ROS-negative samples (p < 0.05). After density gradient centrifugation, only seven of the 38 ROS-positive samples (18.42%) exhibited a ROS-positive lower layer (containing motile sperm) with a ROS removal rate of 81.58%, whereas the upper layer was ROS-positive in 24 samples (63.16%). In the ROS-negative group (n = 105), ROS was detected in 19 samples after centrifugation (18.10%, ROS generation rate), of which 18 were ROS-positive only in the upper layer or interface and the other was ROS-positive in both layers. Density gradient centrifugation can separate motile sperm from immotile sperm as well as remove ROS (including newly generated ROS). This data supports the view that density gradient centrifugation can select motile spermatozoa without enhancing oxidative stress. ROS: reactive oxygen species; SOD: superoxide dismutase; GPx: glutathione peroxidase; DNA: deoxyribonucleic acid; DGC: density gradient centrifugation; IUI: intrauterine insemination; IVF: in vitro fertilization; HEPES: 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid; EDTA: ethylenediaminetetraacetic acid; HTF: HEPES-buffered human tubal fluid; IMSI: intracytoplasmic morphologically selected sperm injection; SMAS: sperm motility analyzing system; CASA: computer-assisted semen analyzer; WHO: World Health Organization.

  14. High-precision positioning system of four-quadrant detector based on the database query

    NASA Astrophysics Data System (ADS)

    Zhang, Xin; Deng, Xiao-guo; Su, Xiu-qin; Zheng, Xiao-qiang

    2015-02-01

    The fine pointing mechanism of the Acquisition, Pointing and Tracking (APT) system in free space laser communication usually use four-quadrant detector (QD) to point and track the laser beam accurately. The positioning precision of QD is one of the key factors of the pointing accuracy to APT system. A positioning system is designed based on FPGA and DSP in this paper, which can realize the sampling of AD, the positioning algorithm and the control of the fast swing mirror. We analyze the positioning error of facular center calculated by universal algorithm when the facular energy obeys Gauss distribution from the working principle of QD. A database is built by calculation and simulation with MatLab software, in which the facular center calculated by universal algorithm is corresponded with the facular center of Gaussian beam, and the database is stored in two pieces of E2PROM as the external memory of DSP. The facular center of Gaussian beam is inquiry in the database on the basis of the facular center calculated by universal algorithm in DSP. The experiment results show that the positioning accuracy of the high-precision positioning system is much better than the positioning accuracy calculated by universal algorithm.

  15. DuPont Qualicon BAX System polymerase chain reaction assay. Performance Tested Method 100201.

    PubMed

    Tice, George; Andaloro, Bridget; Fallon, Dawn; Wallace, F Morgan

    2009-01-01

    A recent outbreak of Salmonella in peanut butter has highlighted the need for validation of rapid detection methods. A multilaboratory study for detecting Salmonella in peanut butter was conducted as part of the AOAC Research Institute Emergency Response Validation program for methods that detect outbreak threats to food safety. Three sites tested spiked samples from the same master mix according to the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA-BAM) method and the BAX System method. Salmonella Typhimurium (ATCC 14028) was grown in brain heart infusion for 24 h at 37 degrees C, then diluted to appropriate levels for sample inoculation. Master samples of peanut butter were spiked at high and low target levels, mixed, and allowed to equilibrate at room temperature for 2 weeks. Spike levels were low [1.08 most probable number (MPN)/25 g]; high (11.5 MPN/25 g) and unspiked to serve as negative controls. Each master sample was divided into 25 g portions and coded to blind the samples. Twenty portions of each spiked master sample and five portions of the unspiked sample were tested at each site. At each testing site, samples were blended in 25 g portions with 225 mL prewarmed lactose broth until thoroughly homogenized, then allowed to remain at room temperature for 55-65 min. Samples were adjusted to a pH of 6.8 +/- 0.2, if necessary, and incubated for 22-26 h at 35 degrees C. Across the three reporting laboratories, the BAX System detected Salmonella in 10/60 low-spike samples and 58/60 high-spike samples. The reference FDA-BAM method yielded positive results for 11/60 low-spike and 58/60 high-spike samples. Neither method demonstrated positive results for any of the 15 unspiked samples.

  16. Performance of VITEK® MS V3.0 for the Identification of Mycobacterium species from Patient Samples using Automated Liquid Media Systems.

    PubMed

    Miller, Eric; Cantrell, Christopher; Beard, Melodie; Derylak, Andrew; Babady, N Esther; McMillen, Tracy; Miranda, Edwin; Body, Barbara; Tang, Yi-Wei; Vasireddy, Ravikiran; Vasireddy, Sruthi; Smith, Terry; Iakhiaeva, Elena; Wallace, Richard J; Brown-Elliott, Barbara A; Moreno, Erik; Totty, Heather; Deol, Parampal

    2018-06-06

    The accuracy and robustness of the VITEK® MS V3.0 matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) system was evaluated by identifying mycobacteria from automated liquid media systems using patient samples. This is the first report demonstrating that proteins within the liquid media, its supplements, and decontamination reagents for non-sterile patient samples do not generate misidentification or false positive results when using the VITEK MS V3.0 system. Prior to testing with patient samples, a seeded study was conducted to challenge the accuracy of the VITEK MS to identify mycobacteria from liquid media through mimicking a clinical workflow. A total of 77 Mycobacterium strains representing 21 species, seeded in simulated sputum, were decontaminated and inoculated into BACT/ALERT®MP liquid culture medium, incubated until positivity, and identified using VITEK MS. A total of 383 liquid cultures were tested of which 379 (99%) identified correctly to the species/complex/group; four (1%) obtained a No Identification, and no misidentifications were observed. Following the simulated sputum study, a total of 73 smear-positive liquid medium cultures detected using BD BBL™ MGIT™ and VersaTREK® MYCO liquid media were identified by VITEK MS. Sixty-four (87.7%) correctly identified to the species/complex/group level; seven (9.6%) resulted as No Identification, and two (2.7%) misidentified at the species level. These results indicate the VITEK MS V3.0 is an accurate tool for routine diagnostics of Mycobacterium species isolated from liquid cultures. Copyright © 2018 American Society for Microbiology.

  17. Multiscale spectral nanoscopy

    DOEpatents

    Yang, Haw; Welsher, Kevin

    2016-11-15

    A system and method for non-invasively tracking a particle in a sample is disclosed. The system includes a 2-photon or confocal laser scanning microscope (LSM) and a particle-holding device coupled to a stage with X-Y and Z position control. The system also includes a tracking module having a tracking excitation laser, X-Y and Z radiation-gathering components configured to detect deviations of the particle in an X-Y and Z directions. The system also includes a processor coupled to the X-Y and Z radiation gathering components, generate control signals configured to drive the stage X-Y and Z position controls to track the movement of the particle. The system may also include a synchronization module configured to generate LSM pixels stamped with stage position and a processing module configured to generate a 3D image showing the 3D trajectory of a particle using the LSM pixels stamped with stage position.

  18. A satellite digital controller or 'play that PID tune again, Sam'. [Position, Integral, Derivative feedback control algorithm for design strategy

    NASA Technical Reports Server (NTRS)

    Seltzer, S. M.

    1976-01-01

    The problem discussed is to design a digital controller for a typical satellite. The controlled plant is considered to be a rigid body acting in a plane. The controller is assumed to be a digital computer which, when combined with the proposed control algorithm, can be represented as a sampled-data system. The objective is to present a design strategy and technique for selecting numerical values for the control gains (assuming position, integral, and derivative feedback) and the sample rate. The technique is based on the parameter plane method and requires that the system be amenable to z-transform analysis.

  19. X-ray tomographic image magnification process, system and apparatus therefor

    DOEpatents

    Kinney, J.H.; Bonse, U.K.; Johnson, Q.C.; Nichols, M.C.; Saroyan, R.A.; Massey, W.N.; Nusshardt, R.

    1993-09-14

    A computerized three-dimensional x-ray tomographic microscopy system is disclosed, comprising: (a) source means for providing a source of parallel x-ray beams, (b) staging means for staging and sequentially rotating a sample to be positioned in the path of the (c) x-ray image magnifier means positioned in the path of the beams downstream from the sample, (d) detecting means for detecting the beams after being passed through and magnified by the image magnifier means, and (e) computing means for analyzing values received from the detecting means, and converting the values into three-dimensional representations. Also disclosed is a process for magnifying an x-ray image, and apparatus therefor. 25 figures.

  20. X-ray tomographic image magnification process, system and apparatus therefor

    DOEpatents

    Kinney, John H.; Bonse, Ulrich K.; Johnson, Quintin C.; Nichols, Monte C.; Saroyan, Ralph A.; Massey, Warren N.; Nusshardt, Rudolph

    1993-01-01

    A computerized three-dimensional x-ray tomographic microscopy system is disclosed, comprising: a) source means for providing a source of parallel x-ray beams, b) staging means for staging and sequentially rotating a sample to be positioned in the path of the c) x-ray image magnifier means positioned in the path of the beams downstream from the sample, d) detecting means for detecting the beams after being passed through and magnified by the image magnifier means, and e) computing means for analyzing values received from the detecting means, and converting the values into three-dimensional representations. Also disclosed is a process for magnifying an x-ray image, and apparatus therefor.

  1. High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas® CT/NG.

    PubMed

    Marlowe, Elizabeth M; Hardy, David; Krevolin, Mark; Gohl, Peter; Bertram, Alexander; Arcenas, Rodney; Seiverth, Britta; Schneider, Tanja; Liesenfeld, Oliver

    2017-09-01

    We compared the analytical and clinical performance of cobas ® CT/NG for use on the Cobas ® 6800/8800 Systems with the Cobas ® 4800 CT/NG Test from urogenital and extragenital specimens in over 12,000 specimens from both male and female subjects in Germany and the United States. The analytical sensitivity was ≤40 EB/ml for Chlamydia trachomatis (CT) and ≤1 CFU/ml for Neisseria gonorrhoeae (NG). Using clinical specimens, the overall percent agreement with the Cobas ® 4800 CT/NG Test was >98.5%. Across urogenital specimens, there were 93 discrepant specimens; 76 (93.8%) of 81 CT discrepant specimens were 6800+/4800- and 10 (83.3%) of 12 NG discrepant specimens were 6800+/4800-. Sequencing verified CT results for 45 (61.6%) of 73 samples positive by 6800 and 1 (20%) of 5 positive by 4800. Similarly, 7 (70.0%) of 10 NG samples positive by 6800 and 1 of 2 positive by 4800 were confirmed by sequencing. Among discrepant extragenital specimens (all 6800+/4800-), 7 (50%) of 14 oropharyngeal and 23 (76.7%) of 30 anorectal CT discordant samples were confirmed as CT positive by sequencing; all 8 anorectal and 20 (90.9%) of 22 oropharyngeal NG discordant results were also confirmed as NG positive. In conclusion, Cobas ® CT/NG for use on the Cobas ® 6800/8800 Systems provides high-throughput automated solutions for sexually transmitted infection (STI) screening programs.

  2. Rapid Multiplex PCR Assay To Identify Respiratory Viral Pathogens: Moving Forward Diagnosing The Common Cold

    PubMed Central

    Gordon, Sarah M; Elegino-Steffens, Diane U; Agee, Willie; Barnhill, Jason; Hsue, Gunther

    2013-01-01

    Upper respiratory tract infections (URIs) can be a serious burden to the healthcare system. The majority of URIs are viral in etiology, but definitive diagnosis can prove difficult due to frequently overlapping clinical presentations of viral and bacterial infections, and the variable sensitivity, and lengthy turn-around time of viral culture. We tested new automated nested multiplex PCR technology, the FilmArray® system, in the TAMC department of clinical investigations, to determine the feasibility of replacing the standard viral culture with a rapid turn-around system. We conducted a feasibility study using a single-blinded comparison study, comparing PCR results with archived viral culture results from a convenience sample of cryopreserved archived nasopharyngeal swabs from acutely ill ED patients who presented with complaints of URI symptoms. A total of 61 archived samples were processed. Viral culture had previously identified 31 positive specimens from these samples. The automated nested multiplex PCR detected 38 positive samples. In total, PCR was 94.5% concordant with the previously positive viral culture results. However, PCR was only 63.4% concordant with the negative viral culture results, owing to PCR detection of 11 additional viral pathogens not recovered on viral culture. The average time to process a sample was 75 minutes. We determined that an automated nested multiplex PCR is a feasible alternative to viral culture in an acute clinical setting. We were able to detect at least 94.5% as many viral pathogens as viral culture is able to identify, with a faster turn-around time. PMID:24052914

  3. Heavy Lift Helicopter - Cargo Handling ATC Program, Volume III. Results of Tests, Inspections, and Evaluations

    DTIC Science & Technology

    1976-10-01

    construc- tion should consider the losses incurred by the E samples and the 2.4% bending/wrap pressure los1 (TOD) incurred by the A-6 sample with respect...charging condi- tions. These elements should be deleted . 418j 2. Grounding Pole a) The contact hook did not ensure positive contact with the load or... deleted as a requirement for the HLH prototype during the ATC program. However, the system was included in the ITR and span position changes were

  4. Accurate Identification of ALK Positive Lung Carcinoma Patients: Novel FDA-Cleared Automated Fluorescence In Situ Hybridization Scanning System and Ultrasensitive Immunohistochemistry

    PubMed Central

    Conde, Esther; Suárez-Gauthier, Ana; Benito, Amparo; Garrido, Pilar; García-Campelo, Rosario; Biscuola, Michele; Paz-Ares, Luis; Hardisson, David; de Castro, Javier; Camacho, M. Carmen; Rodriguez-Abreu, Delvys; Abdulkader, Ihab; Ramirez, Josep; Reguart, Noemí; Salido, Marta; Pijuán, Lara; Arriola, Edurne; Sanz, Julián; Folgueras, Victoria; Villanueva, Noemí; Gómez-Román, Javier; Hidalgo, Manuel; López-Ríos, Fernando

    2014-01-01

    Background Based on the excellent results of the clinical trials with ALK-inhibitors, the importance of accurately identifying ALK positive lung cancer has never been greater. However, there are increasing number of recent publications addressing discordances between FISH and IHC. The controversy is further fuelled by the different regulatory approvals. This situation prompted us to investigate two ALK IHC antibodies (using a novel ultrasensitive detection-amplification kit) and an automated ALK FISH scanning system (FDA-cleared) in a series of non-small cell lung cancer tumor samples. Methods Forty-seven ALK FISH-positive and 56 ALK FISH-negative NSCLC samples were studied. All specimens were screened for ALK expression by two IHC antibodies (clone 5A4 from Novocastra and clone D5F3 from Ventana) and for ALK rearrangement by FISH (Vysis ALK FISH break-apart kit), which was automatically captured and scored by using Bioview's automated scanning system. Results All positive cases with the IHC antibodies were FISH-positive. There was only one IHC-negative case with both antibodies which showed a FISH-positive result. The overall sensitivity and specificity of the IHC in comparison with FISH were 98% and 100%, respectively. Conclusions The specificity of these ultrasensitive IHC assays may obviate the need for FISH confirmation in positive IHC cases. However, the likelihood of false negative IHC results strengthens the case for FISH testing, at least in some situations. PMID:25248157

  5. Cost Analysis of Various Low Pathogenic Avian Influenza Surveillance Systems in the Dutch Egg Layer Sector

    PubMed Central

    Rutten, Niels; Gonzales, José L.; Elbers, Armin R. W.; Velthuis, Annet G. J.

    2012-01-01

    Background As low pathogenic avian influenza viruses can mutate into high pathogenic viruses the Dutch poultry sector implemented a surveillance system for low pathogenic avian influenza (LPAI) based on blood samples. It has been suggested that egg yolk samples could be sampled instead of blood samples to survey egg layer farms. To support future decision making about AI surveillance economic criteria are important. Therefore a cost analysis is performed on systems that use either blood or eggs as sampled material. Methodology/Principal Findings The effectiveness of surveillance using egg or blood samples was evaluated using scenario tree models. Then an economic model was developed that calculates the total costs for eight surveillance systems that have equal effectiveness. The model considers costs for sampling, sample preparation, sample transport, testing, communication of test results and for the confirmation test on false positive results. The surveillance systems varied in sampled material (eggs or blood), sampling location (farm or packing station) and location of sample preparation (laboratory or packing station). It is shown that a hypothetical system in which eggs are sampled at the packing station and samples prepared in a laboratory had the lowest total costs (i.e. € 273,393) a year. Compared to this a hypothetical system in which eggs are sampled at the farm and samples prepared at a laboratory, and the currently implemented system in which blood is sampled at the farm and samples prepared at a laboratory have 6% and 39% higher costs respectively. Conclusions/Significance This study shows that surveillance for avian influenza on egg yolk samples can be done at lower costs than surveillance based on blood samples. The model can be used in future comparison of surveillance systems for different pathogens and hazards. PMID:22523543

  6. Salmonella Prevalence and Antimicrobial Susceptibility from the National Animal Health Monitoring System Sheep 2011 Study.

    PubMed

    Dargatz, David A; Marshall, Katherine L; Fedorka-Cray, Paula J; Erdman, Matthew M; Kopral, Christine A

    2015-12-01

    Salmonella is a major cause of foodborne illness and can cause clinical disease in animals. Understanding the on-farm ecology of Salmonella will be helpful in decreasing the risk of foodborne transmission. An objective of this study was to determine the prevalence of Salmonella among fecal samples collected on sheep operations in the United States. Another objective was to compare the use of composite fecal samples with fecal samples collected from individual sheep as a tool for screening sheep flocks for Salmonella. Sheep fecal samples (individual and composite) were collected on operations in 22 states. Salmonella isolates were characterized with regard to species, serotype, and antimicrobial susceptibility profile. Most operations (72.1%) had at least one positive sample and overall 26.9% of samples were positive. The percentage of positive samples varied by animal age class. Composite and individual samples gave similar results. The majority of the isolates (94%) were Salmonella enterica subspecies diarizonae serotype 61:-:1,5,7. Nearly all of the isolates (91.2%) tested for antimicrobial susceptibility were susceptible to all antimicrobials in the panel. The findings suggest that salmonellae typically associated with foodborne disease transmission are infrequently found on sheep operations in the United States.

  7. Diagnostic usefulness of Xpert MTB/RIF assay for detection of tuberculous meningitis using cerebrospinal fluid.

    PubMed

    Rufai, Syed Beenish; Singh, Amit; Singh, Jitendra; Kumar, Parveen; Sankar, Manimuthu Mani; Singh, Sarman

    2017-08-01

    Tuberculous meningitis (TBM) is the most severe form of extra-pulmonary tuberculosis (TB) due to association of diseases with high rates of mortality and morbidity. Diagnosis continues to be a clinical challenge as microbiological confirmation is rare and time consuming resulting in delayed treatment. Xpert MTB/RIF assay is a rapid and simple test, which has been endorsed by World Health Organization as an initial diagnostic test for the diagnosis of TBM. However, evidence still lacks for its performance on cerebrospinal fluid (CSF) for the diagnosis of TBM especially from India. A total of 267 CSF samples from patients with high clinico-radiological suspicion of TBM were included in this study. Ziehl-Neelsen (ZN) staining, BACTEC Mycobacterial Growth Indicator Tube (MGIT-960) culture system, and Xpert MTB/RIF assay (using cartridge version G4) were tested on all samples. Of total 267 samples, all were negative for smear AFB and 52 (19.5%) were culture positive by MGIT-960 culture system. However, out of 52 (19.5%) cultures detected positive by MGIT-960, 5 (9.6%) were detected as resistant to rifampicin. Xpert MTB/RIF assay was positive in 38 (14.2%) samples and negative in 223 (83.5%) samples. Cartridge error was detected in 6 (2.2%) samples, which could not be repeated due to insufficient sample volume. The sensitivity and specificity of Xpert MTB/RIF assay in comparison to MGIT-960 was 55.1% (95%, CI: 40.2-69.3) and 94.8% (95%, CI: 90.9-97.4) respectively. Overall, Xpert MTB/RIF assay detected 38 (14.2%) as positive for MTB of which 4 (10.5%), 31 (81.6%) and 3 (7.9%) were found to be rifampicin resistant, sensitive and indeterminate respectively. Xpert MTB/RIF assay showed lower sensitivity as compared to MGIT 960 culture for the diagnosis of TBM from CSF samples. Copyright © 2017 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  8. Incidence of Enteric Viruses in Groundwater from Household Wells in Wisconsin

    PubMed Central

    Borchardt, Mark A.; Bertz, Phil D.; Spencer, Susan K.; Battigelli, David A.

    2003-01-01

    Recent studies on the contamination of groundwater with human enteric viruses have focused on public water systems, whereas little is known about the occurrence of viruses in private household wells. The objective of the present study was to estimate the incidence of viruses in Wisconsin household wells located near septage land application sites or in rural subdivisions served by septic systems. Fifty wells in seven hydrogeologic districts were sampled four times over a year, once each season. Reverse transcriptase PCR (RT-PCR), followed by Southern hybridization, was used to detect enteroviruses, rotavirus, hepatitis A virus (HAV), and Norwalk-like viruses (NLVs). In addition, cell culture was used to detect culturable enteroviruses. Companion water samples were collected for total coliforms, Escherichia coli, fecal enterococci, F-specific RNA coliphages, nitrate, and chloride analyses. Among the 50 wells, four (8%) were positive for viruses by RT-PCR. Three wells were positive for HAV, and the fourth well was positive for both rotavirus and NLV in one sample and an enterovirus in another sample. Contamination was transient, since none of the wells was virus positive for two sequential samples. Culturable enteroviruses were not detected in any of the wells. Water quality indicators were not statistically associated with virus occurrence, although some concordance was noted for chloride. The present study is the first in the United States to systematically monitor private household wells for virus contamination and, combined with data for public wells, provides further insight on the extent of groundwater contamination with human enteric viruses. PMID:12571044

  9. Influence of Laser Radiation Power Density on the Intensity of Spectral Lines for Main Components in a Clay Laser-Induced Plasma

    NASA Astrophysics Data System (ADS)

    Anufrik, S. S.; Kurian, N. N.; Znosko, K. F.; Belkov, M. V.

    2018-05-01

    We have studied the intensity of the spectral lines for the main components in clay: Al I 309.4 nm, Al II 358.7 nm, Mg II 279.6 nm, Ti II 323.6 nm vs. the position of the object relative to the focus of the optical system when the samples are exposed to single laser pulses from a YAG:Nd3+ laser. We have determined the permissible ranges for positioning the object relative to the focus of the optical system (positive and negative defocusing) for which there is practically no change in the reproducibility of the intensity for the spectral lines for red and white clay samples. We show that the position of the object relative to the focus of the optical system should be within the range ΔZ ±1.5 mm for optimal laser pulse energies for the analyte spectral lines. We have calculated the radiation flux density for different laser pulse energies and different distances from the focus to the object. We have shown experimentally that reducing the radiation flux density leads to a decrease in the intensity of the analyte spectral lines.

  10. Determining Locations by Use of Networks of Passive Beacons

    NASA Technical Reports Server (NTRS)

    Okino, Clayton; Gray, Andrew; Jennings, Esther

    2009-01-01

    Networks of passive radio beacons spanning moderate-sized terrain areas have been proposed to aid navigation of small robotic aircraft that would be used to explore Saturn s moon Titan. Such networks could also be used on Earth to aid navigation of robotic aircraft, land vehicles, or vessels engaged in exploration or reconnaissance in situations or locations (e.g., underwater locations) in which Global Positioning System (GPS) signals are unreliable or unavailable. Prior to use, it would be necessary to pre-position the beacons at known locations that would be determined by use of one or more precise independent global navigation system(s). Thereafter, while navigating over the area spanned by a given network of passive beacons, an exploratory robot would use the beacons to determine its position precisely relative to the known beacon positions (see figure). If it were necessary for the robot to explore multiple, separated terrain areas spanned by different networks of beacons, the robot could use a long-haul, relatively coarse global navigation system for the lower-precision position determination needed during transit between such areas. The proposed method of precise determination of position of an exploratory robot relative to the positions of passive radio beacons is based partly on the principles of radar and partly on the principles of radio-frequency identification (RFID) tags. The robot would transmit radar-like signals that would be modified and reflected by the passive beacons. The distance to each beacon would be determined from the roundtrip propagation time and/or round-trip phase shift of the signal returning from that beacon. Signals returned from different beacons could be distinguished by means of their RFID characteristics. Alternatively or in addition, the antenna of each beacon could be designed to radiate in a unique pattern that could be identified by the navigation system. Also, alternatively or in addition, sets of identical beacons could be deployed in unique configurations such that the navigation system could identify their unique combinations of radio-frequency reflections as an alternative to leveraging the uniqueness of the RFID tags. The degree of dimensional accuracy would depend not only on the locations of the beacons but also on the number of beacon signals received, the number of samples of each signal, the motion of the robot, and the time intervals between samples. At one extreme, a single sample of the return signal from a single beacon could be used to determine the distance from that beacon and hence to determine that the robot is located somewhere on a sphere, the radius of which equals that distance and the center of which lies at the beacon. In a less extreme example, the three-dimensional position of the robot could be determined with fair precision from a single sample of the signal from each of three beacons. In intermediate cases, position estimates could be refined and/or position ambiguities could be resolved by use of supplementary readings of an altimeter and other instruments aboard the robot.

  11. A "live" biopsy in a small-cell lung cancer patient by detection of circulating tumor cells.

    PubMed

    Bevilacqua, Simona; Gallo, Marianna; Franco, Renato; Rossi, Antonio; De Luca, Antonella; Rocco, Gaetano; Botti, Gerardo; Gridelli, Cesare; Normanno, Nicola

    2009-07-01

    A 71-year-old patient with a pulmonary lesion was diagnosed with a low-grade neuroendocrine tumor following examination of a fine needle aspiration biopsy. Analysis of a peripheral blood sample with the CellSearch system revealed the presence of putative circulating tumor cells (CTC) that were positive for EpCAM and cytokeratin (CK) expression. Since EpCAM is not usually expressed in neuroendocrine tumors, we performed a biopsy of liver metastases. Morphological and immunophenotypical characterization revealed that the patient had an EpCAM and CK positive small-cell lung cancer (SCLC). By using the CellSearch apparatus, EpCAM/CK positive CTC were detected in peripheral blood samples from 3 out of 4 additional SCLC patients. This study is the first to demonstrate that CTC can be identified in SCLC patients by using the CellSearch system.

  12. Experimental technique for studying high-temperature phases in reactive molten metal based systems

    NASA Astrophysics Data System (ADS)

    Ermoline, A.; Schoenitz, M.; Hoffmann, V. K.; Dreizin, E. L.

    2004-12-01

    Containerless, microgravity experiments for studying equilibria in molten metal-gas systems have been designed and conducted onboard of a NASA KC-135 aircraft flying parabolic trajectories. An experimental apparatus enabling one to acoustically levitate, laser heat, and splat quench 1-3 mm metal and ceramic samples has been developed and equipped with computer-based controller and optical diagnostics. Normal-gravity testing determined the levitator operation parameters providing stable and adjustable sample positioning. A methodology for optimizing the levitator performance using direct observation of levitated samples was developed and found to be more useful than traditional pressure mapping of the acoustic field. In microgravity experiments, spherical specimens prepared of pressed, premixed powders of ZrO2, ZrN, and Zr, were acoustically levitated inside an argon-filled chamber at one atmosphere and heated by a CO2 laser up to 2800 K. Using a uniaxial acoustic levitator in microgravity, the location of the laser-heated samples could be maintained for about 1 s, so that local sample melting was achieved. Oscillations of the levitating samples in horizontal direction became pronounced in microgravity. These oscillations increased during the sample heating and eventually resulted in moving the sample out of the stable position and away from the laser beam.

  13. Detection of quinolones in commercial eggs obtained from farms in the Espaíllat Province in the Dominican Republic.

    PubMed

    Moscoso, S; de los Santos, F Solís; Andino, A G; Diaz-Sanchez, Sandra; Hanning, I

    2015-01-01

    Previously, we reported the use of quinolones in broiler chickens resulted in residues in retail poultry meat obtained from nine districts in the Santiago Province of the Dominican Republic. Residues in poultry products are a concern due to consumer allergies and the potential to develop antibiotic-resistant bacteria. Given the use of quinolones in poultry production and our previous findings in poultry meat, the objective of this study was to evaluate the presence of quinolone residues in eggs. Samples were collected from 48 different farms located in three of the four municipalities (Moca, Cayetano Germosén, and Jamao) of the Espaíllat Province. Each farm was sampled three times between July and September for a total of 144 samples. Samples were evaluated qualitatively and quantitatively for quinolone residues using the Equinox test. Operation systems (cage or floor), seasonality, and location were considered along with egg-producer sizes that were defined as small scale, <30,000 eggs per day; medium scale, 30,000 to 60,000 eggs per day; or large scale, >60,000 eggs per day. From small-, medium-, and large-scale producers, 69, 50, and 40% of samples were positive for quinolone residues, respectively. A greater number of samples were positive (61%) in floor-laying hen producers compared with those using cages (40%). In the Jamao municipality, 67% of the samples were positive compared with Moca and Cayetano Germosén, where 56 and 25% of samples were positive, respectively. Sampling time had an effect on percent positives: samples collected in July, August, and September were 71, 19, and 63% positive, respectively. Overall, 51% of the samples obtained from eggs produced in the province of Espaíllat were positive for quinolone residues at levels higher than the maximum limits for edible tissue established by the regulatory agencies, including the European Union and U.S. Department of Agriculture. The results obtained from this research confirmed the presence of quinolone residue in eggs, which may present a health risk to some consumers.

  14. 40 CFR 141.857 - Routine monitoring requirements for public water systems serving more than 1,000 people.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... REGULATIONS Revised Total Coliform Rule § 141.857 Routine monitoring requirements for public water systems... systems serving more than 1,000 persons. (2) Following any total coliform-positive sample taken under the... calendar month has been completed, systems must determine whether any coliform treatment technique triggers...

  15. Beam Position Monitoring in the CSU Accelerator Facility

    NASA Astrophysics Data System (ADS)

    Einstein, Joshua; Vankeuren, Max; Watras, Stephen

    2014-03-01

    A Beam Position Monitoring (BPM) system is an integral part of an accelerator beamline, and modern accelerators can take advantage of newer technologies and designs when creating a BPM system. The Colorado State University (CSU) Accelerator Facility will include four stripline detectors mounted around the beamline, a low-noise analog front-end, and digitization and interface circuitry. The design will support a sampling rate greater than 10 Hz and sub-100 μm accuracy.

  16. Evaluation of dried blood spot as an alternative sample collection method for hepatitis C virus RNA quantitation and genotyping using a commercial system.

    PubMed

    Mahajan, Supriya; Choudhary, Manish Chandra; Kumar, Guresh; Gupta, Ekta

    2018-06-01

    Dried blood spot (DBS) is a minimally invasive sampling method suitable for sample collection, storage and transportation in resource limited areas. Aim of this study was to compare the diagnostic utility of DBS with plasma sample for HCV RNA quantitation and genotyping using commercial systems. Plasma and DBS card spotted samples were collected from 95 HCV seropositive patients. Both types of samples were subjected to HCV RNA by real-time PCR (Abbott m2000rt, USA). Genotyping was performed using Abbott HCV genotype II kit (Abbott diagnostics, USA) in samples with viral load > 3 log 10  IU/ml. In both plasma and DBS, 14 (14.7%) samples were negative and 81 (85.3%) were positive for HCV RNA. Median viral load in plasma (3.78; range 0-7.43) log 10  IU/ml was comparable to DBS (3.93; range 0-7.24) log 10  IU/ml. DBS demonstrated sensitivity and specificity of 97.5 and 85.7% respectively, with positive predictive value (PPV) of 97.5% and negative predictive value (NPV) of 85.7%. DBS showed good correlation (r 2  = 0.866) and agreement (93.5%) with plasma. Genotyping in 20 patients showed 100% concordance between DBS and plasma samples. DBS showed good sensitivity and specificity as a sampling method for HCV RNA quantitation and genotyping.

  17. Biofilm monitoring coupon system and method of use

    NASA Technical Reports Server (NTRS)

    Sauer, Richard L. (Inventor); Flanagan, David T. (Inventor)

    1991-01-01

    An apparatus and method is disclosed for biofilm monitoring of a water distribution system which includes the mounting of at least one fitting in a wall port of a manifold in the water distribution system with a passage through the fitting in communication. The insertion of a biofilm sampling member is through the fitting with planar sampling surfaces of different surface treatment provided on linearly arrayed sample coupons of the sampling member disposed in the flow stream in edge-on parallel relation to the direction of the flow stream of the manifold under fluid-tight sealed conditions. The sampling member is adapted to be aseptically removed from or inserted in the fitting and manifold under a positive pressure condition and the fitting passage sealed immediately thereafter by appropriate closure means so as to preclude contamination of the water distribution system through the fitting. The apparatus includes means for clamping the sampling member and for establishing electrical continuity between the sampling surfaces and the system for minimizing electropotential effects. The apparatus may also include a plurality of fittings and sampling members mounted on the manifold to permit extraction of the sampling members in a timed sequence throughout the monitoring period.

  18. A new multiplex real-time polymerase chain reaction assay for the diagnosis of periprosthetic joint infection.

    PubMed

    Kawamura, Masaki; Kobayashi, Naomi; Inaba, Yutaka; Choe, Hyonmin; Tezuka, Taro; Kubota, So; Saito, Tomoyuki

    2017-11-01

    A new multiplex real-time polymerase chain reaction (PCR) assay was developed to detect methicillin-resistant Staphylococcus (MRS) and to distinguish between gram-positive and gram-negative bacteria. In this study, we validated the sensitivity and specificity of this assay with periprosthetic joint infections (PJIs) and evaluated the utility of PCR for culture-negative PJI. Forty-five samples from 23 infectious PJI cases and 106 samples from 64 non-infectious control cases were analyzed by real-time PCR using a LightCycler Nano ® system. Twenty-eight clinical samples, comprising bacteria of known species isolated consecutively in the microbiological laboratory of our hospital, were used to determine the spectrum of bacterial species that could be detected using the new multiplex primers and probes. The sensitivity and specificity of the MRS- and universal-PCR assays were 92% and 99%, and 91% and 88%, respectively. Twenty-eight species of clinically isolated bacteria were detected using this method and the concordance rate for the identification of gram-positive or gram-negative organisms was 96%. Eight samples were identified as PCR-positive despite a culture-negative result. This novel multiplex real-time PCR system has acceptable sensitivity and specificity and several advantages; therefore, it has potential use for the diagnosis of PJIs, particularly in culture-negative cases.

  19. [Implementation of vanA and vanB genes by PCR technique research interest in system (Xpert vanA/vanB CepheidR) closed in a laboratory of microbiology in managing an outbreak to Enterococcus faecium resistant glycopeptide (EfRG)].

    PubMed

    Dekeyser, S; Beclin, E; Descamps, D

    2011-04-01

    The closed system PCR for the rapid detection of vanA and vanB genes (Xpert vanA/vanB Cepheid(®)) was evaluated in our laboratory, to improve the rapidity of the response and thus the management of patients and isolation measures during two GRE outbreaks. From March to December2009, 565 samples were analysed by PCR associated to bacterial culture initially for all samples for 2months (n = 75), and thereafter for PCR-positive samples only. In this study, sensitivity and negative predictive values of the PCR were 100%. Specificity was evaluated in the presence and absence of outbreak: 69.3 and 76.8% respectively. The variability of false positive rates between units were lower in nonepidemic than during epidemic phase. The global false positive rate was 23.9%. This easy-to-use technology provides rapid results… four samples are tested in 1h versus 72h for culture. Despite its reagent cost, it represents an important hospital diagnostic tool: improvement of the management of cohorting areas and patient transfer between units, adaptation of isolation measures and treatments. However, culture remains necessary to confirm any positive result obtained by PCR and for epidemiological surveillance. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  20. Effectiveness of child safety seats vs seat belts in reducing risk for death in children in passenger vehicle crashes.

    PubMed

    Elliott, Michael R; Kallan, Michael J; Durbin, Dennis R; Winston, Flaura K

    2006-06-01

    To provide an estimate of benefit, if any, of child restraint systems over seat belts alone for children aged from 2 through 6 years. Cohort study. A sample of children in US passenger vehicle crashes was obtained from the National Highway Transportation Safety Administration by combining cases involving a fatality from the US Department of Transportation Fatality Analysis Reporting System with a probability sample of cases without a fatality from the National Automotive Sampling System. Children in tow-away [corrected] crashes occurring between 1998 and 2003. Use of child restraint systems (rear-facing and forward-facing car seats, and shield and belt-positioning booster seats) vs seat belts. Potentially confounding variables included seating position, vehicle type, model year, driver and passenger ages, and driver survival status. Death of child passengers from injuries incurred during the crash. Compared with seat belts, child restraints, when not seriously misused (eg, unattached restraint, child restraint system harness not used, 2 children restrained with 1 seat belt) were associated with a 28% reduction in risk for death (relative risk, 0.72; 95% confidence interval, 0.54-0.97) in children aged 2 through 6 years after adjusting for seating position, vehicle type, model year, driver and passenger ages, and driver survival status. When including cases of serious misuse, the effectiveness estimate was slightly lower (21%) (relative risk, 0.79; 95% confidence interval, 0.59-1.05). Based on these findings as well as previous epidemiological and biomechanical evidence for child restraint system effectiveness in reducing nonfatal injury risk, efforts should continue to promote use of child restraint systems through improved laws and with education and disbursement programs.

  1. Marine Bacteria Cause False-Positive Results in the Colilert-18 Rapid Identification Test for Escherichia coli in Florida Waters

    PubMed Central

    Pisciotta, John M.; Rath, Damon F.; Stanek, Paul A.; Flanery, D. Michael; Harwood, Valerie J.

    2002-01-01

    The Colilert-18 system for enumeration of total coliforms and Escherichia coli is approved by the U.S. Environmental Protection Agency for use in drinking water analysis and is also used by various agencies and research studies for enumeration of indicator organisms in fresh and saline waters. During monitoring of Pinellas County, Fla., marine waters, estimates of E. coli numbers (by Colilert-18) frequently exceeded fecal coliform counts (by membrane filtration) by 1 to 3 orders of magnitude. Samples from freshwater sites did not display similar discrepancies. Fecal coliforms, including E. coli, could be cultured from 100% of yellow fluorescent wells (denoting E. coli-positive results) inoculated with freshwater samples but could be cultured from only 17.1% of the “positive” wells inoculated with marine samples. Ortho-nitrophenyl-β-d-galactopyranoside (ONPG)-positive or 4-methylumbelliferyl-β-d-glucuronide (MUG)-positive noncoliform bacteria were readily cultured from Colilert-18 test wells inoculated with marine samples. Filtered cell-free seawater did not cause false positives. Coculture preparations of as few as 5 CFU of Vibrio cholerae (ONPG positive) and Providencia sp. (MUG positive) ml−1 inoculated into Colilert-18 caused false-positive E. coli results. Salinity conditions influenced coculture results, as the concentration of coculture inoculum required to cause false positives in most wells increased from about 5 CFU ml−1 in seawater diluted 1:10 with freshwater to ≈5,000 CFU ml−1 in seawater diluted 1:20 with freshwater. Estimated E. coli numbers in various marine water samples processed at the 1:10 dilution ranged from 10 to 7,270 CFU·100 ml−1, while E. coli numbers in the same samples processed at the 1:20 dilution did not exceed 40 CFU·100 ml−1. The lower estimates of E. coli numbers corresponded well with fecal coliform counts by membrane filtration. This study indicates that assessment of E. coli in subtropical marine waters by Colilert-18 is not accurate when the recommended 1:10 sample dilution is used. The results suggest that greater dilution may diminish the false-positive problem, but further study of this possibility is recommended. PMID:11823188

  2. Five-year microbiological monitoring of wards and operating theatres in southern Italy.

    PubMed

    La Fauci, V; Genovese, C; Facciolà, A; Palamara, M A R; Squeri, R

    2017-06-01

    Nosocomial infections are one of the greatest problems in public health. Several studies have highlighted the role played by the hospital environment as a possible source of transmission of nosocomial pathogens. A five-year monitoring of bacterial contamination on healthcare workers hands, surfaces most closely in contact with inpatient wards, operating theatres and "at rest" and "in use" operating theatre air samples. For the samples, we used sterile swabs, contact slides, manual API, and automated VITEK systems for identification. In the five-year period, a total of 9396 samples were collected and analysed. In ward patients, 4398 samplings were carried out with 4.7%, 9.4%, 7%, 10.8% and 7.9% positive results respectively from 2010 to 2014. For hands, 648 samplings were carried out, with a positivity of 40.74%. In operating theatres, 4188 samples were taken, with a positivity of 11.9%. Regarding air in empty and full theatres, 1962 samplings were carried out with a positivity rate equal to 31.9%. The monitoring showed a low rate of contamination with a progressive decrease in the fiveyear period on operating theatres surfaces and hands, while there was an increase in the surgical site wards and in the air of operating rooms. Our investigation has revealed the presence of pathogens on the assessed surfaces and the need for environmental monitoring, which can be a valuable tool for reducing contamination.

  3. PubMed Central

    Genovese, C.; Facciolà, A.; Palamara, M.A.R.; Squeri, R.

    2017-01-01

    Summary Introduction. Nosocomial infections are one of the greatest problems in public health. Several studies have highlighted the role played by the hospital environment as a possible source of transmission of nosocomial pathogens. Methods. A five-year monitoring of bacterial contamination on healthcare workers hands, surfaces most closely in contact with inpatient wards, operating theatres and "at rest" and "in use" operating theatre air samples. For the samples, we used sterile swabs, contact slides, manual API, and automated VITEK systems for identification. Results. In the five-year period, a total of 9396 samples were collected and analysed. In ward patients, 4398 samplings were carried out with 4.7%, 9.4%, 7%, 10.8% and 7.9% positive results respectively from 2010 to 2014. For hands, 648 samplings were carried out, with a positivity of 40.74%. In operating theatres, 4188 samples were taken, with a positivity of 11.9%. Regarding air in empty and full theatres, 1962 samplings were carried out with a positivity rate equal to 31.9%. The monitoring showed a low rate of contamination with a progressive decrease in the fiveyear period on operating theatres surfaces and hands, while there was an increase in the surgical site wards and in the air of operating rooms. Conclusions. Our investigation has revealed the presence of pathogens on the assessed surfaces and the need for environmental monitoring, which can be a valuable tool for reducing contamination. PMID:28900357

  4. System and method for assaying radiation

    DOEpatents

    DiPrete, David P; Whiteside, Tad; Pak, Donald J; DiPrete, Cecilia C

    2013-11-12

    A system for assaying radiation includes a sample holder configured to hold a liquid scintillation solution. A photomultiplier receives light from the liquid scintillation solution and generates a signal reflective of the light. A control circuit biases the photomultiplier and receives the signal from the photomultiplier reflective of the light. A light impermeable casing surrounds the sample holder, photomultiplier, and control circuit. A method for assaying radiation includes placing a sample in a liquid scintillation solution, placing the liquid scintillation solution in a sample holder, and placing the sample holder inside a light impermeable casing. The method further includes positioning a photomultiplier inside the light impermeable casing and supplying power to a control circuit inside the light impermeable casing.

  5. Hybrid position and orientation tracking for a passive rehabilitation table-top robot.

    PubMed

    Wojewoda, K K; Culmer, P R; Gallagher, J F; Jackson, A E; Levesley, M C

    2017-07-01

    This paper presents a real time hybrid 2D position and orientation tracking system developed for an upper limb rehabilitation robot. Designed to work on a table-top, the robot is to enable home-based upper-limb rehabilitative exercise for stroke patients. Estimates of the robot's position are computed by fusing data from two tracking systems, each utilizing a different sensor type: laser optical sensors and a webcam. Two laser optical sensors are mounted on the underside of the robot and track the relative motion of the robot with respect to the surface on which it is placed. The webcam is positioned directly above the workspace, mounted on a fixed stand, and tracks the robot's position with respect to a fixed coordinate system. The optical sensors sample the position data at a higher frequency than the webcam, and a position and orientation fusion scheme is proposed to fuse the data from the two tracking systems. The proposed fusion scheme is validated through an experimental set-up whereby the rehabilitation robot is moved by a humanoid robotic arm replicating previously recorded movements of a stroke patient. The results prove that the presented hybrid position tracking system can track the position and orientation with greater accuracy than the webcam or optical sensors alone. The results also confirm that the developed system is capable of tracking recovery trends during rehabilitation therapy.

  6. Laser heating of aqueous samples on a micro-optical-electro-mechanical system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beer, Neil Reginald; Kennedy, Ian

    2013-12-17

    A system of heating a sample on a microchip includes the steps of providing a microchannel flow channel in the microchip; positioning the sample within the microchannel flow channel, providing a laser that directs a laser beam onto the sample for heating the sample; providing the microchannel flow channel with a wall section that receives the laser beam and enables the laser beam to pass through wall section of the microchannel flow channel without being appreciably heated by the laser beam; and providing a carrier fluid in the microchannel flow channel that moves the sample in the microchannel flow channelmore » wherein the carrier fluid is not appreciably heated by the laser beam.« less

  7. Performance of a Novel Algorithm Using Automated Digital Microscopy for Diagnosing Tuberculosis.

    PubMed

    Ismail, Nazir A; Omar, Shaheed V; Lewis, James J; Dowdy, David W; Dreyer, Andries W; van der Meulen, Hermina; Nconjana, George; Clark, David A; Churchyard, Gavin J

    2015-06-15

    TBDx automated microscopy is a novel technology that processes digital microscopic images to identify acid-fast bacilli (AFB). Use of TBDx as part of a diagnostic algorithm could improve the diagnosis of tuberculosis (TB), but its performance characteristics have not yet been formally tested. To evaluate the performance of the TBDx automated microscopy system in algorithms for diagnosis of TB. Prospective samples from patients with presumed TB were processed in parallel with conventional smear microscopy, TBDx microscopy, and liquid culture. All TBDx-positive specimens were also tested with the Xpert MTB/RIF (GXP) assay. We evaluated the sensitivity and specificity of two algorithms-(1) TBDx-GXP (TBDx with positive specimens tested by Xpert MTB/RIF) and (2) TBDx alone-against the gold standard liquid media culture. Of 1,210 samples, 1,009 were eligible for evaluation, of which 109 were culture positive for Mycobacterium tuberculosis. The TBDx system identified 70 specimens (68 culture positive) as having 10 or more putative AFB (high positive) and 207 (19 culture positive) as having 1-9 putative AFB (low positive). An algorithm in which "low-positive" results on TBDx were confirmed by GXP had 78% sensitivity (85 of 109) and 99.8% specificity (889 of 900), requiring 21% (207 of 1,009) specimens to be processed by GXP. As a stand-alone test, a "high-positive" result on TBDx had 62% sensitivity and 99.7% specificity. TBDx used in diagnostic algorithms with GXP provided reasonable sensitivity and high specificity for active TB while dramatically reducing the number GXP tests performed. As a stand-alone microscopy system, its performance was equivalent to that of a highly experienced TB microscopist.

  8. Scanning mass spectrometry with integrated constant distance positioning

    NASA Astrophysics Data System (ADS)

    Li, Nan; Eckhard, Kathrin; Aßmann, Jens; Hagen, Volker; Otto, Horst; Chen, Xingxing; Schuhmann, Wolfgang; Muhler, Martin

    2006-08-01

    Scanning mass spectrometry is of growing importance for the characterization of catalytically active surfaces. The instrument presented here is capable of measuring catalytic activity spatially resolved by means of two concentric capillaries. The outer one is used for cofeeding reactants such as ethene and hydrogen to the sample surface, whereas the inner one is pumping off the product mixture as inlet to a quadrupole mass spectrometer. Three-dimensional measurements under stagnant-point flow conditions become possible based on a home-built capillary positioning unit. Step-motor driven positioning stages exhibiting a minimum step width of 2.5μm̸half step are used for the x, y positioning, and the step motor in z direction has a resolution of 1μm̸half step. The system is additionally equipped with a feedback loop for following the topography of the sample throughout scanning. Hence, the obtained catalytic data are unimpaired by signal changes caused by the morphology of the investigated structure. For distance control the argon ion current is used originating from externally fed argon diffusing into the confined space between the accurately positioned capillaries and the sample surface. A well-defined microchannel flow field with 400μm wide channels and 200μm wide mounds was chosen to evaluate the developed method. The catalytic activity of a Pt catalyst deposited on glassy carbon was successfully visualized in constant probe to sample distance. Simultaneously, the topography of the sample was recorded derived from the z positioning of the capillaries.

  9. Record of hospitalizations for ambulatory care sensitive conditions: validation of the hospital information system.

    PubMed

    Rehem, Tania Cristina Morais Santa Barbara; de Oliveira, Maria Regina Fernandes; Ciosak, Suely Itsuko; Egry, Emiko Yoshikawa

    2013-01-01

    To estimate the sensitivity, specificity and positive and negative predictive values of the Unified Health System's Hospital Information System for the appropriate recording of hospitalizations for ambulatory care-sensitive conditions. The hospital information system records for conditions which are sensitive to ambulatory care, and for those which are not, were considered for analysis, taking the medical records as the gold standard. Through simple random sampling, a sample of 816 medical records was defined and selected by means of a list of random numbers using the Statistical Package for Social Sciences. The sensitivity was 81.89%, specificity was 95.19%, the positive predictive value was 77.61% and the negative predictive value was 96.27%. In the study setting, the Hospital Information System (SIH) was more specific than sensitive, with nearly 20% of care sensitive conditions not detected. There are no validation studies in Brazil of the Hospital Information System records for the hospitalizations which are sensitive to primary health care. These results are relevant when one considers that this system is one of the bases for assessment of the effectiveness of primary health care.

  10. Full-scale studies of factors related to coliform regrowth in drinking water.

    PubMed

    LeChevallier, M W; Welch, N J; Smith, D B

    1996-07-01

    An 18-month survey of 31 water systems in North America was conducted to determine the factors that contribute to the occurrence of coliform bacteria in drinking water. The survey included analysis of assimilable organic carbon (AOC), coliforms, disinfectant residuals, and operational parameters. Coliform bacteria were detected in 27.8% of the 2-week sampling periods and were associated with the following factors: filtration, temperature, disinfectant type and disinfectant level, AOC level, corrosion control, and operational characteristics. Four systems in the study that used unfiltered surface water accounted for 26.6% of the total number of bacterial samples collected but 64.3% (1,013 of 1,576) of the positive coliform samples. The occurrence of coliform bacteria was significantly higher when water temperatures were > 15 degrees C. For filtered systems that used free chlorine, 0.97% of 33,196 samples contained coliform bacteria, while 0.51% of 35,159 samples from chloraminated systems contained coliform bacteria. The average density of coliform bacteria was 35 times higher in free-chlorinated systems than in chloraminated water (0.60 CFU/100 ml for free-chlorinated water compared with 0.017 CFU/100 ml for chloraminated water). Systems that maintained dead-end free chlorine levels of < 0.2 mg/liter or monochloramine levels of < 0.5 mg/liter had substantially more coliform occurrences than systems that maintained higher disinfectant residuals. Free-chlorinated systems with AOC levels greater than 100 micrograms/liter had 82% more coliform-positive samples and 19 times higher coliform levels than free-chlorinated systems with average AOC levels less than 99 micrograms/liter. Systems that maintained a phosphate-based corrosion inhibitor and limited the amount of unlined cast iron pipe had fewer coliform bacteria. Several operational characteristics of the treatment process or the distribution system were also associated with increased rates of coliform occurrence. The study concludes that the occurrence of coliform bacteria within a distribution system is dependent upon a complex interaction of chemical, physical, operational, and engineering parameters. No one factor could account for all of the coliform occurrences, and one must consider all of the parameters described above in devising a solution to the regrowth problem.

  11. Full-scale studies of factors related to coliform regrowth in drinking water.

    PubMed Central

    LeChevallier, M W; Welch, N J; Smith, D B

    1996-01-01

    An 18-month survey of 31 water systems in North America was conducted to determine the factors that contribute to the occurrence of coliform bacteria in drinking water. The survey included analysis of assimilable organic carbon (AOC), coliforms, disinfectant residuals, and operational parameters. Coliform bacteria were detected in 27.8% of the 2-week sampling periods and were associated with the following factors: filtration, temperature, disinfectant type and disinfectant level, AOC level, corrosion control, and operational characteristics. Four systems in the study that used unfiltered surface water accounted for 26.6% of the total number of bacterial samples collected but 64.3% (1,013 of 1,576) of the positive coliform samples. The occurrence of coliform bacteria was significantly higher when water temperatures were > 15 degrees C. For filtered systems that used free chlorine, 0.97% of 33,196 samples contained coliform bacteria, while 0.51% of 35,159 samples from chloraminated systems contained coliform bacteria. The average density of coliform bacteria was 35 times higher in free-chlorinated systems than in chloraminated water (0.60 CFU/100 ml for free-chlorinated water compared with 0.017 CFU/100 ml for chloraminated water). Systems that maintained dead-end free chlorine levels of < 0.2 mg/liter or monochloramine levels of < 0.5 mg/liter had substantially more coliform occurrences than systems that maintained higher disinfectant residuals. Free-chlorinated systems with AOC levels greater than 100 micrograms/liter had 82% more coliform-positive samples and 19 times higher coliform levels than free-chlorinated systems with average AOC levels less than 99 micrograms/liter. Systems that maintained a phosphate-based corrosion inhibitor and limited the amount of unlined cast iron pipe had fewer coliform bacteria. Several operational characteristics of the treatment process or the distribution system were also associated with increased rates of coliform occurrence. The study concludes that the occurrence of coliform bacteria within a distribution system is dependent upon a complex interaction of chemical, physical, operational, and engineering parameters. No one factor could account for all of the coliform occurrences, and one must consider all of the parameters described above in devising a solution to the regrowth problem. PMID:8779557

  12. Methods and compositions for rapid thermal cycling

    DOEpatents

    Beer, Neil Reginald; Benett, William J.; Frank, James M.; Deotte, Joshua R.; Spadaccini, Christopher

    2015-10-27

    The rapid thermal cycling of a material is targeted. A microfluidic heat exchanger with an internal porous medium is coupled to tanks containing cold fluid and hot fluid. Fluid flows alternately from the cold tank and the hot tank into the porous medium, cooling and heating samples contained in the microfluidic heat exchanger's sample wells. A valve may be coupled to the tanks and a pump, and switching the position of the valve may switch the source and direction of fluid flowing through the porous medium. A controller may control the switching of valve positions based on the temperature of the samples and determined temperature thresholds. A sample tray for containing samples to be thermally cycled may be used in conjunction with the thermal cycling system. A surface or internal electrical heater may aid in heating the samples, or may replace the necessity for the hot tank.

  13. Methods and compositions for rapid thermal cycling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beer, Neil Reginald; Benett, William J.; Frank, James M.

    The rapid thermal cycling of a material is targeted. A microfluidic heat exchanger with an internal porous medium is coupled to tanks containing cold fluid and hot fluid. Fluid flows alternately from the cold tank and the hot tank into the porous medium, cooling and heating samples contained in the microfluidic heat exchanger's sample wells. A valve may be coupled to the tanks and a pump, and switching the position of the valve may switch the source and direction of fluid flowing through the porous medium. A controller may control the switching of valve positions based on the temperature ofmore » the samples and determined temperature thresholds. A sample tray for containing samples to be thermally cycled may be used in conjunction with the thermal cycling system. A surface or internal electrical heater may aid in heating the samples, or may replace the necessity for the hot tank.« less

  14. Transition of carbon nanostructures in heptane diffusion flames

    NASA Astrophysics Data System (ADS)

    Hu, Wei-Chieh; Hou, Shuhn-Shyurng; Lin, Ta-Hui

    2017-02-01

    The flame synthesis has high potential in industrial production of carbon nanostructure (CNS). Unfortunately, the complexity of combustion chemistry leads to less controlling of synthesized products. In order to improve the understanding of the relation between flames and CNSs synthesized within, experiments were conducted through heptane flames in a stagnation-point liquid-pool system. The operating parameters for the synthesis include oxygen supply, sampling position, and sampling time. Two kinds of nanostructures were observed, carbon nanotube (CNT) and carbon nano-onion (CNO). CNTs were synthesized in a weaker flame near extinction. CNOs were synthesized in a more sooty flame. The average diameter of CNTs formed at oxygen concentration of 15% was in the range of 20-30 nm. For oxygen concentration of 17%, the average diameter of CNTs ranged from 24 to 27 nm, while that of CNOs was around 28 nm. For oxygen concentration of 19%, the average diameter of CNOs produced at the sampling position 0.5 mm below the flame front was about 57 nm, while the average diameters of CNOs formed at the sampling positions 1-2.5 mm below the flame front were in the range of 20-25 nm. A transition from CNT to CNO was observed by variation of sampling position in a flame. We found that the morphology of CNS is directly affected by the presence of soot layer due to the carbonaceous environment and the growth mechanisms of CNT and CNO. The sampling time can alter the yield of CNSs depending on the temperature of sampling position, but the morphology of products is not affected.

  15. Development and Validation of a Semiquantitative, Multitarget PCR Assay for Diagnosis of Bacterial Vaginosis

    PubMed Central

    Lembke, Bryndon D.; Ramachandran, Kalpana; Body, Barbara A.; Nye, Melinda B.; Rivers, Charles A.; Schwebke, Jane R.

    2012-01-01

    Quantitative PCR assays were developed for 4 organisms reported previously to be useful positive indicators for the diagnosis of bacterial vaginosis (BV)—Atopobium vaginae, Bacterial Vaginosis-Associated Bacterium 2 (BVAB-2), Gardnerella vaginalis, and Megasphaera-1—and a single organism (Lactobacillus crispatus) that has been implicated as a negative indicator for BV. Vaginal samples (n = 169), classified as positive (n = 108) or negative (n = 61) for BV based on a combination of the Nugent Gram stain score and Amsel clinical criteria, were analyzed for the presence and quantity of each of the marker organisms, and the results were used to construct a semiquantitative, multiplex PCR assay for BV based on detection of 3 positive indicator organisms (A. vaginae, BVAB-2, and Megasphaera-1) and classification of samples using a combinatorial scoring system. The prototype BV PCR assay was then used to analyze the 169-member developmental sample set and, in a prospective, blinded manner, an additional 227 BV-classified vaginal samples (110 BV-positive samples and 117 BV-negative samples). The BV PCR assay demonstrated a sensitivity of 96.7% (202/209), a specificity of 92.2% (153/166), a positive predictive value of 94.0%, and a negative predictive value of 95.6%, with 21 samples (5.3%) classified as indeterminate for BV. This assay provides a reproducible and objective means of evaluating critical components of the vaginal microflora in women with signs and symptoms of vaginitis and is comparable in diagnostic accuracy to the conventional gold standard for diagnosis of BV. PMID:22535982

  16. Autoclave sterilization of instruments used on women with cervical neoplasia is an effective method of eradicating residual human papillomavirus DNA: a polymerase chain reaction-based evaluation.

    PubMed

    Estes, Jacob M; Kirby, Tyler O; Huh, Warner K

    2007-01-01

    To determine whether autoclave sterilization eradicates human papillomavirus (HPV) DNA on specula and instruments used to treat women with cervical neoplasia. Specula and instruments used in two referral colposcopy clinics were evaluated to determine the PGMY9/11 primer system's ability to amplify residual HPV DNA. Each speculum and instrument was sampled with a Dacron swab and stored in PreservCyt solution (Cytyc Corporation, Marlborough, MA) at 4 degrees C. DNA amplification was performed under standard conditions with appropriate controls followed by HPV typing using the reverse line blot test (Roche Molecular Systems, Alameda, CA). Once validated, the same polymerase chain reaction method was used on autoclave-sterilized specula and biopsy instruments and heated glass bead- and Cidex bath (Johnson & Johnson, New Brunswick, NJ)-sterilized instruments. All results, with appropriate positive and negative controls, were confirmed in triplicate. A total of 140 instruments (70 used and 70 autoclaved) were sampled for residual HPV DNA. Five samples in the contaminated specula arm were excluded from analysis secondary to insufficient sampling. Of the remaining samples, 52.3% (34/65) of contaminated instruments-both specula and biopsy instruments-had detectable HPV DNA. Fifty-five percent of contaminated biopsy instruments (11/20) were positive and 51.1% of contaminated specula (23/45) were positive. All 70 autoclaved samples (50 specula and 20 biopsy instruments) were negative for residual HPV DNA or beta-globin. One instrument in the glass bead and Cidex group that was presumed sterile was positive for HPV 16 DNA. The PGMY9/11 primer system is an effective method to detect residual HPV DNA. Autoclave sterilization appears to eradicate HPV DNA to levels undetectable with this sensitive assay, whereas heated glass beads followed by Cidex bath appears to be inadequate methods. These results suggest that autoclave sterilization is effective when using nondisposable instruments and should be the method of choice in studies using polymerase chain reaction-based amplification of HPV DNA.

  17. 3M™ Molecular detection system versus MALDI-TOF mass spectrometry and molecular techniques for the identification of Escherichia coli 0157:H7, Salmonella spp. &Listeria spp.

    PubMed

    Loff, Marché; Mare, Louise; de Kwaadsteniet, Michele; Khan, Wesaal

    2014-06-01

    The aim of this study was to compare standard selective plating, conventional PCR (16S rRNA and species specific primers), MALDI-TOF MS and the 3M™ Molecular Detection System for the routine detection of the pathogens Listeria, Salmonella and Escherichia coli 0157:H7 in wastewater and river water samples. MALDI-TOF MS was able to positively identify 20/21 (95%) of the E. coli isolates obtained at genus and species level, while 16S rRNA sequencing only correctly identified 6/21 (28%) as E. coli strains. None of the presumptive positive Listeria spp. and Salmonella spp. isolates obtained by culturing on selective media were positively identified by MALDI-TOF and 16S rRNA analysis. The species-specific E. coli 0157:H7 PCR described in this present study, was not able to detect any E. coli 0157:H7 strains in the wastewater and river water samples analysed. However, E. coli strains, Listeria spp., L. monocytogenes and Salmonella spp. were detected using species specific PCR. Escherichia coli 0157:H7, Listeria spp. and Salmonella spp. were also sporadically detected throughout the sampling period in the wastewater and river water samples analysed by the 3M™ Molecular Detection System. MALDI-TOF MS, which is a simple, accurate and cost-effective detection method, efficiently identified the culturable organisms, while in the current study both species specific PCR (Listeria spp. and Salmonella spp.) and 3M™ Molecular Detection System could be utilised for the direct routine analysis of pathogens in water sources. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas® CT/NG

    PubMed Central

    Marlowe, Elizabeth M.; Hardy, David; Krevolin, Mark; Gohl, Peter; Bertram, Alexander; Arcenas, Rodney; Seiverth, Britta; Schneider, Tanja; Liesenfeld, Oliver

    2017-01-01

    We compared the analytical and clinical performance of cobas® CT/NG for use on the Cobas® 6800/8800 Systems with the Cobas® 4800 CT/NG Test from urogenital and extragenital specimens in over 12,000 specimens from both male and female subjects in Germany and the United States. The analytical sensitivity was ≤40 EB/ml for Chlamydia trachomatis (CT) and ≤1 CFU/ml for Neisseria gonorrhoeae (NG). Using clinical specimens, the overall percent agreement with the Cobas® 4800 CT/NG Test was >98.5%. Across urogenital specimens, there were 93 discrepant specimens; 76 (93.8%) of 81 CT discrepant specimens were 6800+/4800– and 10 (83.3%) of 12 NG discrepant specimens were 6800+/4800–. Sequencing verified CT results for 45 (61.6%) of 73 samples positive by 6800 and 1 (20%) of 5 positive by 4800. Similarly, 7 (70.0%) of 10 NG samples positive by 6800 and 1 of 2 positive by 4800 were confirmed by sequencing. Among discrepant extragenital specimens (all 6800+/4800–), 7 (50%) of 14 oropharyngeal and 23 (76.7%) of 30 anorectal CT discordant samples were confirmed as CT positive by sequencing; all 8 anorectal and 20 (90.9%) of 22 oropharyngeal NG discordant results were also confirmed as NG positive. In conclusion, Cobas® CT/NG for use on the Cobas® 6800/8800 Systems provides high-throughput automated solutions for sexually transmitted infection (STI) screening programs. PMID:29034107

  19. 40 CFR 141.861 - Reporting and recordkeeping.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... recordkeeping. (a) Reporting—(1) E. coli. (i) A system must notify the State by the end of the day when the system learns of an E. coli MCL violation, unless the system learns of the violation after the State... by the end of the day when the system is notified of an E. coli-positive routine sample, unless the...

  20. 40 CFR 141.861 - Reporting and recordkeeping.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... recordkeeping. (a) Reporting. (1) E. coli.—(i) A system must notify the State by the end of the day when the system learns of an E. coli MCL violation, unless the system learns of the violation after the State... by the end of the day when the system is notified of an E. coli-positive routine sample, unless the...

  1. Evaluation of negative results of BacT/Alert 3D automated blood culture system.

    PubMed

    Kocoglu, M Esra; Bayram, Aysen; Balci, Iclal

    2005-06-01

    Although automated continuous-monitoring blood culture systems are both rapid and sensitive, false-positive and false-negative results still occur. The objective of this study, then, was to evaluate negative results occurring with BacT/Alert 3D blood culture systems. A total of 1032 samples were cultured with the BacT/Alert 3D automated blood culture system, using both aerobic (FA) and anaerobic (FN) [corrected] media, and 128 of these samples yielded positive results. A total of 904 negative blood samples were then subcultured in 5% sheep blood agar, eosin methylene blue, chocolate agar, and sabouraud-dextrose agar. Organisms growing on these subcultures were subsequently identified using both Vitek32 (bioMerieux, Durham, NC) and conventional methods. Twenty four (2.6%) of the 904 subcultures grew on the subculture media. The majority (83.3%) of these were determined to be gram-positive microorganisms. Fourteen (58.3%) were coagulase-negative staphylococci, two (8.3%) were Bacillus spp., one (4.2%) was Staphylococcus aureus, and one (4.2%) was identified as Enterococcus faecium. Streptococcus pneumoniae and Neisseria spp. were isolated together in two (8.3%) vials. Gram-negative microorganisms comprised 12.5% of the subcultures, of which two (8.3%) were found to be Pseudomonas aeruginosa, and one (4.2%) was Pseudomonas fluorescens. The other isolate (4.2%) was identified as Candida albicans. We conclude that the subculture of negative results is valuable in the BacT/Alert 3D system, especially in situations in which only one set of blood cultures is taken.

  2. On the accuracy and reliability of predictions by control-system theory.

    PubMed

    Bourbon, W T; Copeland, K E; Dyer, V R; Harman, W K; Mosley, B L

    1990-12-01

    In three experiments we used control-system theory (CST) to predict the results of tracking tasks on which people held a handle to keep a cursor even with a target on a computer screen. 10 people completed a total of 104 replications of the task. In each experiment, there were two conditions: in one, only the handle affected the position of the cursor; in the other, a random disturbance also affected the cursor. From a person's performance during Condition 1, we derived constants used in the CST model to predict the results of Condition 2. In two experiments, predictions occurred a few minutes before Condition 2; in one experiment, the delay was 1 yr. During a 1-min. experimental run, the positions of handle and cursor, produced by the person, were each sampled 1800 times, once every 1/30 sec. During a modeling run, the model predicted the positions of the handle and target for each of the 1800 intervals sampled in the experimental run. In 104 replications, the mean correlation between predicted and actual positions of the handle was .996; SD = .002.

  3. Vibration Pattern Imager (VPI): A control and data acquisition system for scanning laser vibrometers

    NASA Technical Reports Server (NTRS)

    Rizzi, Stephen A.; Brown, Donald E.; Shaffer, Thomas A.

    1993-01-01

    The Vibration Pattern Imager (VPI) system was designed to control and acquire data from scanning laser vibrometer sensors. The PC computer based system uses a digital signal processing (DSP) board and an analog I/O board to control the sensor and to process the data. The VPI system was originally developed for use with the Ometron VPI Sensor, but can be readily adapted to any commercially available sensor which provides an analog output signal and requires analog inputs for control of mirror positioning. The sensor itself is not part of the VPI system. A graphical interface program, which runs on a PC under the MS-DOS operating system, functions in an interactive mode and communicates with the DSP and I/O boards in a user-friendly fashion through the aid of pop-up menus. Two types of data may be acquired with the VPI system: single point or 'full field.' In the single point mode, time series data is sampled by the A/D converter on the I/O board (at a user-defined sampling rate for a selectable number of samples) and is stored by the PC. The position of the measuring point (adjusted by mirrors in the sensor) is controlled via a mouse input. The mouse input is translated to output voltages by the D/A converter on the I/O board to control the mirror servos. In the 'full field' mode, the measurement point is moved over a user-selectable rectangular area. The time series data is sampled by the A/D converter on the I/O board (at a user-defined sampling rate for a selectable number of samples) and converted to a root-mean-square (rms) value by the DSP board. The rms 'full field' velocity distribution is then uploaded for display and storage on the PC.

  4. Rapid Determination of Salmonella in Samples of Egg Noodles, Cake Mixes, and Candies

    PubMed Central

    Banwart, George J.; Kreitzer, Madeleine J.

    1969-01-01

    A glass apparatus system was compared with a standard enrichment broth-selective agar method to test samples of egg noodles, cake mixes, and candy for the presence or absence of salmonellae. The glass apparatus system used fermentation of mannitol, production of H2S, or motility, in conjunction with a serological test of flagellar antigens, to detect salmonellae. No salmonellae were detected in 173 samples of food products. Of these samples, 171 were found to be Salmonella-negative after 48 hr with the glass apparatus system. After 72 hr, the standard Salmonella procedure yielded 38 samples which produced Salmonella false-positive results on selective agars. Inoculation of samples with cultures of Salmonella showed that approximately one inoculated cell could be detected after 48 hr of incubation with the glass apparatus. The standard Salmonella test requires a minimum of 72 hr for completion. Compared with the standard Salmonella test, the glass apparatus system is a more rapid and simple system that can be used to determine the presence or absence of Salmonella in these food products. Images PMID:5370460

  5. West Nile virus--neutralizing antibodies in humans in Greece.

    PubMed

    Papa, Anna; Perperidou, Parthena; Tzouli, Anisa; Castilletti, Concetta

    2010-10-01

    Serum samples collected during March-May 2007 from 392 residents of Imathia prefecture, Northern Greece, were tested by indirect immunofluorescence assay and enzyme-linked immunosorbent assay for IgG antibodies against West Nile virus (WNV). Microneutralization assay was applied in six positive samples. Four (4/392, 1.02%) were found positive for WNV-neutralizing antibodies. None of the positive individuals had a history of travel in endemic area or flavivirus vaccination, suggesting that WNV, or an antigenically related flavivirus, circulates in an endemic sylvatic cycle, at least locally, in rural areas in Greece. Human, animal, and vector surveillance systems have to be implemented to provide an early detection of WNV activity in Greece.

  6. A prototype sensor system for the early detection of microbially linked spoilage in stored wheat grain

    NASA Astrophysics Data System (ADS)

    de Lacy Costello, B. P. J.; Ewen, R. J.; Gunson, H.; Ratcliffe, N. M.; Sivanand, P. S.; Spencer-Phillips, P. T. N.

    2003-04-01

    Sensors based on composites of metal oxides were fabricated and tested extensively under high-humidity and high-flow conditions with exposure to vapours reported to increase in the headspace of wheat grain (Triticum aestivum cv Hereward) colonized by fungi. The sensors that exhibited high sensitivity to target vapours combined with high stability were selected for inclusion into a four-sensor array prototype system. A sampling protocol aligned to parallel gas chromatography-mass spectrometry and human olfactory assessment studies was established for use with the sensor system. The sensor system was utilized to assess irradiated wheat samples that had been conditioned to 25% moisture content and inoculated with pathogens known to cause spoilage of grain in storage. These included the fungi Penicillium aurantiogriseum, Penicillium vulpinum, Penicillium verrucosum, Fusarium culmorum, Aspergillus niger, and Aspergillus flavus and the actinomycete, Streptomyces griseus. The sensor system successfully tracked the progress of the infections from a very early stage and the results were compared with human olfactory assessment panels run concurrently. A series of dilution studies were undertaken using previously infected grain mixed with sound grain, to improve the sensitivity and maximize the differentiation of the sensor system. An optimum set of conditions including incubation temperature, incubation time, sampling time, and flow rate were ascertained utilizing this method. The sensor system differentiated samples of sound grain from samples of sound grain with 1% (w/w) fungus infected grain added. Following laboratory trials, the prototype sensor system was evaluated in a commercial wheat grain intake facility. Thresholds calculated from laboratory tests were used to differentiate between sound and infected samples (classified by intake laboratory technicians) collected routinely from trucks delivering grain for use in food manufacture. All samples identified as having an odour-related problem by the intake laboratory gave a total system output above the set threshold and were therefore rejected by the prototype system. A number of samples passed by the intake laboratory were rejected by the prototype system, resulting in what appeared to be false positive results. However, the thresholds were selected on the basis of a limited number of samples and may need to be adjusted to minimize false positives. The output from the sensor system was also compared with moisture content values for the wheat (where available) to demonstrate that the system was not simply measuring differences in moisture. A separate study (carried out at the intake facility) assessed 37 newly harvested wheat samples of different varieties and from different geographic locations within the UK. These samples were analysed by the sensor system, using the same thresholds as before. Six samples rejected by the system were then assessed by the wheat intake laboratory, where only one sample was rejected. This rejected sample had given the highest output when exposed to the sensor system. The commercial trial highlighted the promise of this prototype for the detection of spoilage in wheat grain and a larger trial should ascertain the reliability and long-term stability of the device and therefore confirm its usefulness to the industry.

  7. Object Locating System

    NASA Technical Reports Server (NTRS)

    Arndt, G. Dickey (Inventor); Carl, James R. (Inventor)

    2000-01-01

    A portable system is provided that is operational for determining, with three dimensional resolution, the position of a buried object or approximately positioned object that may move in space or air or gas. The system has a plurality of receivers for detecting the signal front a target antenna and measuring the phase thereof with respect to a reference signal. The relative permittivity and conductivity of the medium in which the object is located is used along with the measured phase signal to determine a distance between the object and each of the plurality of receivers. Knowing these distances. an iteration technique is provided for solving equations simultaneously to provide position coordinates. The system may also be used for tracking movement of an object within close range of the system by sampling and recording subsequent position of the object. A dipole target antenna. when positioned adjacent to a buried object, may be energized using a separate transmitter which couples energy to the target antenna through the medium. The target antenna then preferably resonates at a different frequency, such as a second harmonic of the transmitter frequency.

  8. The influence of electron discharge and magnetic field on calcium carbonate (CaCO{sub 3}) precipitation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Putro, Triswantoro, E-mail: tris@physics.its.ac.id; Endarko, E-mail: endarko@physics.its.ac.id

    The influences of electron discharge and magnetic field on calcium carbonate (CaCO{sub 3}) precipitation in water have been successfully investigated. The study used three pairs of magnetic field 0.1 T whilst the electron discharge was generated from television flyback transformer type BW00607 and stainless steel SUS 304 as an electrode. The water sample with an initial condition of 230 mg/L placed in the reactor with flow rate 375 mL/minutes, result showed that the electron discharge can be reduced contain of calcium carbonate the water sample around 17.39% within 2 hours. Meanwhile for the same long period of treatment and flow rate, aroundmore » 56.69% from initial condition of 520 mg/L of calcium carbonate in the water sample can be achieved by three pairs of magnetic field 0.1 T. When the combination of three pairs of magnetic field 0.1 T and the electron discharge used for treatment, the result showed that the combination of electron discharge and magnetic field methods can be used to precipitate calcium carbonate in the water sample 300 mg/L around 76.66% for 2 hours of treatment. The study then investigated the influence of the polar position of the magnetic field on calcium carbonate precipitation. Two positions of magnetic field were tested namely the system with alternated polar magnetics and the system without inversion of the polar magnetics. The influence of the polar position showed that the percentage reduction in levels of calcium carbonate in the water sample (360 mg/L) is significant different. Result showed that the system without inversion of the polar magnetics is generally lower than the system with alternated polar magnetics, with reduction level at 30.55 and 57.69%, respectively.« less

  9. Harmonic-phase path-integral approximation of thermal quantum correlation functions

    NASA Astrophysics Data System (ADS)

    Robertson, Christopher; Habershon, Scott

    2018-03-01

    We present an approximation to the thermal symmetric form of the quantum time-correlation function in the standard position path-integral representation. By transforming to a sum-and-difference position representation and then Taylor-expanding the potential energy surface of the system to second order, the resulting expression provides a harmonic weighting function that approximately recovers the contribution of the phase to the time-correlation function. This method is readily implemented in a Monte Carlo sampling scheme and provides exact results for harmonic potentials (for both linear and non-linear operators) and near-quantitative results for anharmonic systems for low temperatures and times that are likely to be relevant to condensed phase experiments. This article focuses on one-dimensional examples to provide insights into convergence and sampling properties, and we also discuss how this approximation method may be extended to many-dimensional systems.

  10. [Value of positive auto controls in the gel centrifugation method].

    PubMed

    Eichler, H; Kretschmer, V

    1994-01-01

    We studied 97 samples of patients being positive in the autocontrol of the indirect antiglobulin test (IAT) in the gel system (DiaMed). In 83.2%, retesting with monospecific anti-IgG serum gave also positive results, due to a specific phenomenon caused, for example, by drug-specific antibodies (AB), warm auto-AB or allo-AB. In contrast, only 52.9% of the samples retested by the standard tube technique with polyspecific antiglobulin serum reacted positive. Only in 6 patients slightly increased cold agglutinins could be detected. None of the investigated patients showed any clinical or laboratory signs of hemolysis except one with pernicious anemia. We conclude that positive results of the autocontrol in the gel IAT should be confirmed by an additional DAT in the tube technique. If this second test shows a negative result, transfusions can take place without any restrictions.

  11. Tracking the eye non-invasively: simultaneous comparison of the scleral search coil and optical tracking techniques in the macaque monkey

    PubMed Central

    Kimmel, Daniel L.; Mammo, Dagem; Newsome, William T.

    2012-01-01

    From human perception to primate neurophysiology, monitoring eye position is critical to the study of vision, attention, oculomotor control, and behavior. Two principal techniques for the precise measurement of eye position—the long-standing sclera-embedded search coil and more recent optical tracking techniques—are in use in various laboratories, but no published study compares the performance of the two methods simultaneously in the same primates. Here we compare two popular systems—a sclera-embedded search coil from C-N-C Engineering and the EyeLink 1000 optical system from SR Research—by recording simultaneously from the same eye in the macaque monkey while the animal performed a simple oculomotor task. We found broad agreement between the two systems, particularly in positional accuracy during fixation, measurement of saccade amplitude, detection of fixational saccades, and sensitivity to subtle changes in eye position from trial to trial. Nonetheless, certain discrepancies persist, particularly elevated saccade peak velocities, post-saccadic ringing, influence of luminance change on reported position, and greater sample-to-sample variation in the optical system. Our study shows that optical performance now rivals that of the search coil, rendering optical systems appropriate for many if not most applications. This finding is consequential, especially for animal subjects, because the optical systems do not require invasive surgery for implantation and repair of search coils around the eye. Our data also allow laboratories using the optical system in human subjects to assess the strengths and limitations of the technique for their own applications. PMID:22912608

  12. EGFR mutation status of paired cerebrospinal fluid and plasma samples in EGFR mutant non-small cell lung cancer with leptomeningeal metastases.

    PubMed

    Zhao, Jing; Ye, Xin; Xu, Yan; Chen, Minjiang; Zhong, Wei; Sun, Yun; Yang, Zhenfan; Zhu, Guanshan; Gu, Yi; Wang, Mengzhao

    2016-12-01

    Central nervous system (CNS) is the prevalent site for metastases in epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor (TKI)-relapsed NSCLC patients. To understand the EGFR mutation status in paired cerebrospinal fluid (CSF) and plasma samples after EGFR-TKI treatment failure might be useful to guide the treatment of intra- and extracranial tumors in those patients. Paired CSF and plasma samples were collected from seven NSCLC patients with CNS metastases after EGFR-TKI failure. EGFR mutations were tested by amplification refractory mutation system (ARMS) and droplet digital PCR (ddPCR) methods. Gefitinib concentrations were evaluated by high-performance liquid chromatography-mass spectrometry (HPLC-MS/MS). EGFR mutations were detected in all seven CSF samples, including three of E19-Del, three of L858R and one of E19-Del&T790M by both methods. On the other hand, majority of the matched plasma samples (5/7) were negative for EGFR mutations by both methods. The other two plasma samples were positive for E19-Del&T790M by ddPCR, and one of them had undetectable T790M by ARMS. Gefitinib concentration in CSF was much lower than that in plasma (mean CSF/plasma ratio: 1.8 %). After EGFR-TKI failure, majority of the NSCLC patients with CNS metastases remained positive detection of EGFR sensitive mutations in CSF, but much less detection in the matched plasma. Significantly low exposure of gefitinib in CSF might explain the intracranial protection of the EGFR sensitive mutation positive tumor cells.

  13. Outbreak or illusion: consequences of 'improved' diagnostics for gonorrhoea.

    PubMed

    Bennett, Amy; Jeffery, Katie; O'Neill, Eunan; Sherrard, Jackie

    2017-06-01

    The sexual health service in Oxford introduced gonorrhoea nucleic amplification acid testing using the BD Viper XTR™ System. For practical reasons, a confirmatory nucleic amplification acid testing using a different platform was not used initially. Following the introduction of nucleic amplification acid testing, the rates of gonorrhoea increased threefold. Concerns were raised that this increase represented an outbreak. A retrospective review of cases over six months suggested that there may have been a number of false-positive results. A prospective study was then undertaken over six months, where all gonorrhoea positive samples were sent for confirmatory testing. This evaluation of all gonorrhoea cases in an English county found that the overall presumptive false-positive rates for gonorrhoea nucleic amplification acid testing using BD Viper XTR™ in our population are significant at 27% of female samples, 13.2% of heterosexual male samples, 3.5% of anogenital multiple site men who have sex with men samples and 62.8% of pharyngeal only men who have sex with men samples. The data demonstrate the need for confirmatory testing using a second nucleic acid target, as per BASHH/Public Health England guidelines, especially in low-prevalence settings and extragenital sites, due to cross-reactivity with commensal Neisseria species and low positive predictive values.

  14. Enumeration of Somatic and F-RNA Phages as an Indicator of Fecal Contamination in Potable Water from Rural Areas of the North West Province.

    PubMed

    Nkwe, Keitumetse Idah; Ateba, Collins Njie; Sithebe, Nomathamsanqa Patricia; Bezuidenhout, Cornelius Carlos

    2015-07-01

    Bacteriophages are regarded as enteric viral indicators in faecally contaminated water systems and may indicate the presence of human viral pollution. They are relatively resistant to inactivation by natural and treatment processes. In this study, the presence of somatic coliphages and F-RNA coliphages was investigated in potable water from rural areas in the North West province. Water samples were aseptically collected from boreholes and tap water from some rural communities in the North West Province. Physical parameters of the water, such as the temperature, pH and turbidity, were measured before sample collection. Double-agar layer assay was performed using ISO, (1995, 2000) standard methods. Bottled water was used as a negative control and the strains фX174 and MS2 as positive controls. Of the 16 water samples collected, 15 were positive for somatic bacteriophages while F-RNA coliphages were detected in only two samples. Amongst the positive samples 189 and three plaque forming units were obtained for both somatic and F-RNA coliphages, respectively. No coliphage was detected in water from Masamane tap 1. The rest of the samples obtained from various rural areas were positive and did not comply with national and international standards for potable water. This was a cause for concern and should be further investigated.

  15. Enumeration of Somatic and F-RNA Phages as an Indicator of Fecal Contamination in Potable Water from Rural Areas of the North West Province

    PubMed Central

    Nkwe, Keitumetse Idah; Ateba, Collins Njie; Sithebe, Nomathamsanqa Patricia; Bezuidenhout, Cornelius Carlos

    2015-01-01

    Bacteriophages are regarded as enteric viral indicators in faecally contaminated water systems and may indicate the presence of human viral pollution. They are relatively resistant to inactivation by natural and treatment processes. In this study, the presence of somatic coliphages and F-RNA coliphages was investigated in potable water from rural areas in the North West province. Water samples were aseptically collected from boreholes and tap water from some rural communities in the North West Province. Physical parameters of the water, such as the temperature, pH and turbidity, were measured before sample collection. Double-agar layer assay was performed using ISO, (1995, 2000) standard methods. Bottled water was used as a negative control and the strains фX174 and MS2 as positive controls. Of the 16 water samples collected, 15 were positive for somatic bacteriophages while F-RNA coliphages were detected in only two samples. Amongst the positive samples 189 and three plaque forming units were obtained for both somatic and F-RNA coliphages, respectively. No coliphage was detected in water from Masamane tap 1. The rest of the samples obtained from various rural areas were positive and did not comply with national and international standards for potable water. This was a cause for concern and should be further investigated. PMID:26140675

  16. Large-Scale Evaluation of the Immuno-Mycologics Lateral Flow and Enzyme-Linked Immunoassays for Detection of Cryptococcal Antigen in Serum and Cerebrospinal Fluid

    PubMed Central

    Hansen, Jessica; Slechta, E. Susan; Gates-Hollingsworth, Marcellene A.; Neary, Brandon; Barker, Adam P.; Bauman, Sean; Kozel, Thomas R.

    2013-01-01

    Cryptococcosis is a systemic infection caused by the pathogenic yeasts Cryptococcus neoformans and C. gattii. Detection of cryptococcal capsular antigen (CrAg) in serum and cerebrospinal fluid (CSF) plays an important diagnostic role. We prospectively compared the new Immuno-Mycologics Inc. (IMMY) lateral flow assay (LFA) and enzyme immunoassay (EIA) to our current CrAg test (Premier EIA; Meridian Bioscience Inc.). Discordant samples were retested with the latex-Cryptococcus antigen test (IMMY) and using serotype-specific monoclonal antibodies (MAbs). A total of 589 serum and 411 CSF specimens were tested in parallel. Qualitative agreement across assays was 97.7%. In all, 56 (41 serum and 15 CSF) samples were positive and 921 (527 serum and 394 CSF) samples were negative by all three assays. The 23 discrepant specimens were all Meridian EIA negative. Of 23 discordant specimens, 20 (87.0%) were positive by both the IMMY LFA and EIA, 2 were LFA positive only, and 1 was EIA positive only. Eleven discrepant specimens had adequate volume for latex agglutination (LA) testing; 8 were LA positive, and 3 were LA negative. LA-negative samples (2 CSF samples and 1 serum) had low IMMY LFA/EIA titers (≤1:10). Serotype-specific MAb analysis of the LA-positive samples suggested that these specimens contained CrAg epitopes similar to those of serotype C strains. In conclusion, the IMMY assays showed excellent overall concordance with the Meridian EIA. Assay performance differences were related to issues of analytic sensitivity and possible serotype bias. Incomplete access to patient-level data combined with low specimen volumes limited our ability to fully resolve discrepant results. PMID:23114703

  17. Large-scale evaluation of the immuno-mycologics lateral flow and enzyme-linked immunoassays for detection of cryptococcal antigen in serum and cerebrospinal fluid.

    PubMed

    Hansen, Jessica; Slechta, E Susan; Gates-Hollingsworth, Marcellene A; Neary, Brandon; Barker, Adam P; Bauman, Sean; Kozel, Thomas R; Hanson, Kimberly E

    2013-01-01

    Cryptococcosis is a systemic infection caused by the pathogenic yeasts Cryptococcus neoformans and C. gattii. Detection of cryptococcal capsular antigen (CrAg) in serum and cerebrospinal fluid (CSF) plays an important diagnostic role. We prospectively compared the new Immuno-Mycologics Inc. (IMMY) lateral flow assay (LFA) and enzyme immunoassay (EIA) to our current CrAg test (Premier EIA; Meridian Bioscience Inc.). Discordant samples were retested with the latex-Cryptococcus antigen test (IMMY) and using serotype-specific monoclonal antibodies (MAbs). A total of 589 serum and 411 CSF specimens were tested in parallel. Qualitative agreement across assays was 97.7%. In all, 56 (41 serum and 15 CSF) samples were positive and 921 (527 serum and 394 CSF) samples were negative by all three assays. The 23 discrepant specimens were all Meridian EIA negative. Of 23 discordant specimens, 20 (87.0%) were positive by both the IMMY LFA and EIA, 2 were LFA positive only, and 1 was EIA positive only. Eleven discrepant specimens had adequate volume for latex agglutination (LA) testing; 8 were LA positive, and 3 were LA negative. LA-negative samples (2 CSF samples and 1 serum) had low IMMY LFA/EIA titers (≤1:10). Serotype-specific MAb analysis of the LA-positive samples suggested that these specimens contained CrAg epitopes similar to those of serotype C strains. In conclusion, the IMMY assays showed excellent overall concordance with the Meridian EIA. Assay performance differences were related to issues of analytic sensitivity and possible serotype bias. Incomplete access to patient-level data combined with low specimen volumes limited our ability to fully resolve discrepant results.

  18. Rainwater harvesting in American Samoa: current practices and indicative health risks.

    PubMed

    Kirs, Marek; Moravcik, Philip; Gyawali, Pradip; Hamilton, Kerry; Kisand, Veljo; Gurr, Ian; Shuler, Christopher; Ahmed, Warish

    2017-05-01

    Roof-harvested rainwater (RHRW) is an important alternative source of water that many island communities can use for drinking and other domestic purposes when groundwater and/or surface water sources are contaminated, limited, or simply not available. The aim of this pilot-scale study was to investigate current RHRW practices in American Samoa (AS) and to evaluate and compare the quality of water from common potable water sources including RHRW stored in tanks, untreated stream water, untreated municipal well water, and treated municipal tap water samples. Samples were analyzed using culture-based methods, quantitative polymerase chain reaction (qPCR), and 16S amplicon sequencing-based methods. Based on indicator bacteria (total coliform and Escherichia coli) concentrations, the quality of RHRW was slightly lower than well and chlorinated tap water but exceeded that of untreated stream water. Although no Giardia or Leptospira spp. were detected in any of the RHRW samples, 86% of the samples were positive for Cryptosporidium spp. All stream water samples tested positive for Cryptosporidium spp. Opportunistic pathogens (Pseudomonas aeruginosa and Mycobacterium intracellulare) were also detected in the RHRW samples (71 and 21% positive samples, respectively). Several potentially pathogenic genera of bacteria were also detected in RHRW by amplicon sequencing. Each RHRW system was characterized by distinct microbial communities, 77% of operational taxonomic units (OTUs) were detected only in a single tank, and no OTU was shared by all the tanks. Risk of water-borne illness increased in the following order: chlorinated tap water/well water < RHRW < stream water. Frequent detection of opportunistic pathogens indicates that RHRW should be treated before use. Stakeholder education on RHRW system design options as well as on importance of regular cleaning and proper management techniques could improve the quality of the RHRW in AS.

  19. Does neutralization of gastric aspirates from children with suspected intrathoracic tuberculosis affect mycobacterial yields on MGIT culture?

    PubMed

    Parashar, Deepak; Kabra, Sushil K; Lodha, Rakesh; Singh, Varinder; Mukherjee, Aparna; Arya, Tina; Grewal, Harleen M S; Singh, Sarman

    2013-06-01

    The microbiological confirmation of pulmonary tuberculosis in children relies on cultures of gastric aspirate (GA) specimens. Conventionally, GAs are neutralized to improve culture yields of mycobacteria. However, there are limited data to support this practice. To study the utility of neutralization of GAs with sodium bicarbonate in children with intrathoracic tuberculosis, a total of 116 children of either sex, aged 6 months to 14 years (median age, 120 months; interquartile range [IQR], 7 to 192 months), underwent gastric aspiration on 2 consecutive days. Gastric aspirates were divided into two aliquots, and only one aliquot was neutralized with 1% sodium bicarbonate. Both aliquots were processed for smear and culture examinations. Out of the 232 gastric aspirates, 12 (5.17%) were acid-fast bacilli (AFB) smear positive. There were no differences in smear positivity rates from samples with or without neutralization. The yield of Mycobacterium tuberculosis on a Bactec MGIT 960 culture system was significantly lower in the neutralized samples (16.3% [38/232]) than in the nonneutralized samples (21.5% [50/232]) (P = 0.023). There was no significant difference between the neutralized and the nonneutralized samples in time to detection using the MGIT 960 system (average, 24.6 days; IQR, 12 to 37 days) (P = 0.9). The contamination rates were significantly higher in the neutralized samples than in the nonneutralized samples (17.2% [40/232] versus 3.9% [9/232]) (P = 0.001). The agreement for positive mycobacterial culture between the two approaches was 66.5% (P = 0.001). Hence, we recommend that gastric aspirate samples not be neutralized with sodium bicarbonate prior to culture for M. tuberculosis.

  20. Improvement of immunoassay detection system by using alternating current magnetic susceptibility

    NASA Astrophysics Data System (ADS)

    Kawabata, R.; Mizoguchi, T.; Kandori, A.

    2016-03-01

    A major goal with this research was to develop a low-cost and highly sensitive immunoassay detection system by using alternating current (AC) magnetic susceptibility. We fabricated an improved prototype of our previously developed immunoassay detection system and evaluated its performance. The prototype continuously moved sample containers by using a magnetically shielded brushless motor, which passes between two anisotropic magneto resistance (AMR) sensors. These sensors detected the magnetic signal in the direction where each sample container passed them. We used the differential signal obtained from each AMR sensor's output to improve the signal-to-noise ratio (SNR) of the magnetic signal measurement. Biotin-conjugated polymer beads with avidin-coated magnetic particles were prepared to examine the calibration curve, which represents the relation between AC magnetic susceptibility change and polymer-bead concentration. For the calibration curve measurement, we, respectively, measured the magnetic signal caused by the magnetic particles by using each AMR sensor installed near the upper or lower part in the lateral position of the passing sample containers. As a result, the SNR of the prototype was 4.5 times better than that of our previous system. Moreover, the data obtained from each AMR sensor installed near the upper part in the lateral position of the passing sample containers exhibited an accurate calibration curve that represented good correlation between AC magnetic susceptibility change and polymer-bead concentration. The conclusion drawn from these findings is that our improved immunoassay detection system will enable a low-cost and highly sensitive immunoassay.

  1. Improvement of immunoassay detection system by using alternating current magnetic susceptibility.

    PubMed

    Kawabata, R; Mizoguchi, T; Kandori, A

    2016-03-01

    A major goal with this research was to develop a low-cost and highly sensitive immunoassay detection system by using alternating current (AC) magnetic susceptibility. We fabricated an improved prototype of our previously developed immunoassay detection system and evaluated its performance. The prototype continuously moved sample containers by using a magnetically shielded brushless motor, which passes between two anisotropic magneto resistance (AMR) sensors. These sensors detected the magnetic signal in the direction where each sample container passed them. We used the differential signal obtained from each AMR sensor's output to improve the signal-to-noise ratio (SNR) of the magnetic signal measurement. Biotin-conjugated polymer beads with avidin-coated magnetic particles were prepared to examine the calibration curve, which represents the relation between AC magnetic susceptibility change and polymer-bead concentration. For the calibration curve measurement, we, respectively, measured the magnetic signal caused by the magnetic particles by using each AMR sensor installed near the upper or lower part in the lateral position of the passing sample containers. As a result, the SNR of the prototype was 4.5 times better than that of our previous system. Moreover, the data obtained from each AMR sensor installed near the upper part in the lateral position of the passing sample containers exhibited an accurate calibration curve that represented good correlation between AC magnetic susceptibility change and polymer-bead concentration. The conclusion drawn from these findings is that our improved immunoassay detection system will enable a low-cost and highly sensitive immunoassay.

  2. Detection of Respiratory Viruses in Sputum from Adults by Use of Automated Multiplex PCR

    PubMed Central

    Walsh, Edward E.; Formica, Maria A.; Falsey, Ann R.

    2014-01-01

    Respiratory tract infections (RTI) frequently cause hospital admissions among adults. Diagnostic viral reverse transcriptase PCR (RT-PCR) of nose and throat swabs (NTS) is useful for patient care by informing antiviral use and appropriate isolation. However, automated RT-PCR systems are not amenable to utilizing sputum due to its viscosity. We evaluated a simple method of processing sputum samples in a fully automated respiratory viral panel RT-PCR assay (FilmArray). Archived sputum and NTS samples collected in 2008-2012 from hospitalized adults with RTI were evaluated. A subset of sputum samples positive for 10 common viruses by a uniplex RT-PCR was selected. A sterile cotton-tip swab was dunked in sputum, swirled in 700 μL of sterile water (dunk and swirl method) and tested by the FilmArray assay. Quantitative RT-PCR was performed on “dunked” sputum and NTS samples for influenza A (Flu A), respiratory syncytial virus (RSV), coronavirus OC43 (OC43), and human metapneumovirus (HMPV). Viruses were identified in 31% of 965 illnesses using a uniplex RT-PCR. The sputum sample was the only sample positive for 105 subjects, including 35% (22/64) of influenza cases and significantly increased the diagnostic yield of NTS alone (302/965 [31%] versus 197/965 [20%]; P = 0.0001). Of 108 sputum samples evaluated by the FilmArray assay using the dunk and swirl method, 99 (92%) were positive. Quantitative RT-PCR revealed higher mean viral loads in dunked sputum samples compared to NTS samples for Flu A, RSV, and HMPV (P = 0.0001, P = 0.006, and P = 0.011, respectively). The dunk and swirl method is a simple and practical method for reliably processing sputum samples in a fully automated PCR system. The higher viral loads in sputa may increase detection over NTS testing alone. PMID:25056335

  3. System and method for liquid extraction electrospray-assisted sample transfer to solution for chemical analysis

    DOEpatents

    Kertesz, Vilmos; Van Berkel, Gary J.

    2016-07-12

    A system for sampling a surface includes a surface sampling probe comprising a solvent liquid supply conduit and a distal end, and a sample collector for suspending a sample collection liquid adjacent to the distal end of the probe. A first electrode provides a first voltage to solvent liquid at the distal end of the probe. The first voltage produces a field sufficient to generate electrospray plume at the distal end of the probe. A second electrode provides a second voltage and is positioned to produce a plume-directing field sufficient to direct the electrospray droplets and ions to the suspended sample collection liquid. The second voltage is less than the first voltage in absolute value. A voltage supply system supplies the voltages to the first electrode and the second electrode. The first electrode can apply the first voltage directly to the solvent liquid. A method for sampling for a surface is also disclosed.

  4. Dengue Virus Serotype 2 Established in Northern Mozambique (2015-2016).

    PubMed

    Oludele, John; Lesko, Birgitta; Mahumane Gundane, Isabel; de Bruycker-Nogueira, Fernanda; Muianga, Argentina; Ali, Sadia; Mula, Flora; Chelene, Imelda; Falk, Kerstin I; Barreto Dos Santos, Flávia; Gudo, Eduardo Samo

    2017-11-01

    After the report of an outbreak of dengue virus serotype 2 in 2014 in Nampula and Pemba cities, northern Mozambique, a surveillance system was established by the National Institute of Health. A study was performed during 2015-2016 to monitor the trend of the outbreak and confirm the circulating serotype of dengue virus (DENV). After the inclusion of consenting patients who met the case definition, samples from 192 patients were tested for the presence of nonstructural protein 1 antigen, and 60/192 (31%) samples were positive. Further analysis included DENV IgM antibodies, with 39 (20%) IgM positive cases. Reverse transcriptase (RT) PCR was performed for identification of the prevailing DENV serotype; 21/23 tested samples were DENV-2 positive, with DENV-2 present in both affected cities. When sequencing DENV, phenotype Cosmopolitan was identified. The surveillance indicates ongoing spread of DENV-2 in northern Mozambique 2 years after the first report of the outbreak.

  5. Distributed Capacitive Sensor for Sample Mass Measurement

    NASA Technical Reports Server (NTRS)

    Toda, Risaku; McKinney, Colin; Jackson, Shannon P.; Mojarradi, Mohammad; Manohara, Harish; Trebi-Ollennu, Ashitey

    2011-01-01

    Previous robotic sample return missions lacked in situ sample verification/ quantity measurement instruments. Therefore, the outcome of the mission remained unclear until spacecraft return. In situ sample verification systems such as this Distributed Capacitive (DisC) sensor would enable an unmanned spacecraft system to re-attempt the sample acquisition procedures until the capture of desired sample quantity is positively confirmed, thereby maximizing the prospect for scientific reward. The DisC device contains a 10-cm-diameter pressure-sensitive elastic membrane placed at the bottom of a sample canister. The membrane deforms under the weight of accumulating planetary sample. The membrane is positioned in close proximity to an opposing rigid substrate with a narrow gap. The deformation of the membrane makes the gap narrower, resulting in increased capacitance between the two parallel plates (elastic membrane and rigid substrate). C-V conversion circuits on a nearby PCB (printed circuit board) provide capacitance readout via LVDS (low-voltage differential signaling) interface. The capacitance method was chosen over other potential approaches such as the piezoelectric method because of its inherent temperature stability advantage. A reference capacitor and temperature sensor are embedded in the system to compensate for temperature effects. The pressure-sensitive membranes are aluminum 6061, stainless steel (SUS) 403, and metal-coated polyimide plates. The thicknesses of these membranes range from 250 to 500 m. The rigid substrate is made with a 1- to 2-mm-thick wafer of one of the following materials depending on the application requirements glass, silicon, polyimide, PCB substrate. The glass substrate is fabricated by a microelectromechanical systems (MEMS) fabrication approach. Several concentric electrode patterns are printed on the substrate. The initial gap between the two plates, 100 m, is defined by a silicon spacer ring that is anodically bonded to the glass substrate. The fabricated proof-of-concept devices have successfully demonstrated tens to hundreds of picofarads of capacitance change when a simulated sample (100 g to 500 g) is placed on the membrane.

  6. Development of Sample Verification System for Sample Return Missions

    NASA Technical Reports Server (NTRS)

    Toda, Risaku; McKinney, Colin; Jackson, Shannon P.; Mojarradi, Mohammad; Trebi-Ollennu, Ashitey; Manohara, Harish

    2011-01-01

    This paper describes the development of a proof of-concept sample verification system (SVS) for in-situ mass measurement of planetary rock and soil sample in future robotic sample return missions. Our proof-of-concept SVS device contains a 10 cm diameter pressure sensitive elastic membrane placed at the bottom of a sample canister. The membrane deforms under the weight of accumulating planetary sample. The membrane is positioned in proximity to an opposing substrate with a narrow gap. The deformation of the membrane makes the gap to be narrower, resulting in increased capacitance between the two nearly parallel plates. Capacitance readout circuitry on a nearby printed circuit board (PCB) transmits data via a low-voltage differential signaling (LVDS) interface. The fabricated SVS proof-of-concept device has successfully demonstrated approximately 1pF/gram capacitance change

  7. Antibiotic resistance pattern and evaluation of metallo-beta lactamase genes (VIM and IMP) in Pseudomonas aeruginosa strains producing MBL enzyme, isolated from patients with secondary immunodeficiency

    PubMed Central

    Shirani, Kiana; Ataei, Behrouz; Roshandel, Fardad

    2016-01-01

    Background: One of the most common causes of hospital-acquired secondary infections in hospitalized patients is Pseudomonas aeruginosa. The aim of this study is to evaluate the expression of IMP and VIM in Pseudomonas aeruginosa strains (carbapenem resistant and producer MBL enzyme) in patients with secondary immunodeficiency. Materials and Methods: In a cross sectional study, 96 patients with secondary immunodeficiency hospitalized in the Al-Zahra hospital were selected. Carbapenem resistant strains isolated and modified Hodge test was performed in order to confirm the presence of the metallo carbapenemase enzyme. Under the standard conditions they were sent to the central laboratory for investigating nosocomial infection Multiplex PCR. Results: Of 96 samples 28.1% were IMP positive, 5.2% VIM positive and 3.1% both VIM and IMP positive. The prevalence of multidrug resistance in the IMP and/or VIM negative samples was 29%, while all 5 VIM positive samples have had multidrug resistance. Also the prevalence of multi-drug resistance in IMP positive samples were 96.3% and in IMP and VIM positive samples were 100%. According to Fisher’s test, the prevalence of multi-drug resistance based on gene expression has significant difference (P < 0.001). Conclusion: Based on the results of this study it can be concluded that, a significant percentage of patients with secondary immunodeficiency that suffer nosocomial infections with multidrug resistance, especially Pseudomonas aeruginosa, are probably MBL-producing gene positive. Therefore the cause of infection should be considered in the hospital care system to identify their features, the presence of genes involved in the development of multi-drug resistance and antibiotic therapy. PMID:27563634

  8. Antibiotic resistance pattern and evaluation of metallo-beta lactamase genes (VIM and IMP) in Pseudomonas aeruginosa strains producing MBL enzyme, isolated from patients with secondary immunodeficiency.

    PubMed

    Shirani, Kiana; Ataei, Behrouz; Roshandel, Fardad

    2016-01-01

    One of the most common causes of hospital-acquired secondary infections in hospitalized patients is Pseudomonas aeruginosa. The aim of this study is to evaluate the expression of IMP and VIM in Pseudomonas aeruginosa strains (carbapenem resistant and producer MBL enzyme) in patients with secondary immunodeficiency. In a cross sectional study, 96 patients with secondary immunodeficiency hospitalized in the Al-Zahra hospital were selected. Carbapenem resistant strains isolated and modified Hodge test was performed in order to confirm the presence of the metallo carbapenemase enzyme. Under the standard conditions they were sent to the central laboratory for investigating nosocomial infection Multiplex PCR. Of 96 samples 28.1% were IMP positive, 5.2% VIM positive and 3.1% both VIM and IMP positive. The prevalence of multidrug resistance in the IMP and/or VIM negative samples was 29%, while all 5 VIM positive samples have had multidrug resistance. Also the prevalence of multi-drug resistance in IMP positive samples were 96.3% and in IMP and VIM positive samples were 100%. According to Fisher's test, the prevalence of multi-drug resistance based on gene expression has significant difference (P < 0.001). Based on the results of this study it can be concluded that, a significant percentage of patients with secondary immunodeficiency that suffer nosocomial infections with multidrug resistance, especially Pseudomonas aeruginosa, are probably MBL-producing gene positive. Therefore the cause of infection should be considered in the hospital care system to identify their features, the presence of genes involved in the development of multi-drug resistance and antibiotic therapy.

  9. Microbiology of broiler carcasses and chemistry of chiller water as affected by water reuse.

    PubMed

    Northcutt, J K; Smith, D; Huezo, R I; Ingram, K D

    2008-07-01

    A study was conducted to determine the effects of treating and reusing poultry chiller water in a commercial poultry processing facility. Broiler carcasses and chiller water were obtained from a commercial processing facility which had recently installed a TOMCO Pathogen Management System to recycle water in sections 2 and 3 of two 3-compartment chillers. In this system, reused water is blended with fresh water to maintain the chiller volume. Carcasses were sampled prechill and postchill (final exit), and chiller water was sampled from the beginning and end of each of the 3 sections. Carcasses were subjected to a whole carcass rinse (WCR) in 0.1% peptone. Numbers of Escherichia coli (EC), coliforms (CF), and Campylobacter (CPY) were determined from the WCR and chiller water samples. Prevalence of Salmonella (SAL) was also determined on the WCR and chiller water samples. On average, prechill levels of bacteria recovered from rinses were 2.6, 2.9, and 2.6 log10 cfu/mL for EC, CF, and CPY, respectively. Ten out of 40 (25%) prechill carcasses were positive for SAL. After chilling, numbers of EC, CF, and CPY recovered from carcass rinses decreased by 1.5, 1.5, and 2.0 log10 cfu/mL, respectively. However, 9 out of 40 (22%) postchill carcasses were positive for SAL. When the chiller water samples were tested, counts of EC, CF, and CPY were found only in water collected from the first section of the chiller (inlet and outlet). Two of 4 water samples collected from the inlet of the first section tested positive for SAL. This study shows that fresh and reused water can be used to cool poultry in chiller systems to achieve a reduction in numbers of bacteria (EC, CF, and CPY) or equivalent prevalence (SAL) of bacteria recovered from broiler carcasses.

  10. Digital-computer normal shock position and restart control of a Mach 2.5 axisymmetric mixed-compression inlet

    NASA Technical Reports Server (NTRS)

    Neiner, G. H.; Cole, G. L.; Arpasi, D. J.

    1972-01-01

    Digital computer control of a mixed-compression inlet is discussed. The inlet was terminated with a choked orifice at the compressor face station to dynamically simulate a turbojet engine. Inlet diffuser exit airflow disturbances were used. A digital version of a previously tested analog control system was used for both normal shock and restart control. Digital computer algorithms were derived using z-transform and finite difference methods. Using a sample rate of 1000 samples per second, the digital normal shock and restart controls essentially duplicated the inlet analog computer control results. At a sample rate of 100 samples per second, the control system performed adequately but was less stable.

  11. Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure with image analysis

    DOEpatents

    Van Berkel, Gary J.; Kertesz, Vilmos

    2011-08-09

    A system and method utilizes an image analysis approach for controlling the collection instrument-to-surface distance in a sampling system for use, for example, with mass spectrometric detection. Such an approach involves the capturing of an image of the collection instrument or the shadow thereof cast across the surface and the utilization of line average brightness (LAB) techniques to determine the actual distance between the collection instrument and the surface. The actual distance is subsequently compared to a target distance for re-optimization, as necessary, of the collection instrument-to-surface during an automated surface sampling operation.

  12. Physical and chemical parameter correlations with technical and technological characteristics of heating systems and the presence of Legionella spp. in the hot water supply.

    PubMed

    Rakić, Anita; Štambuk-Giljanović, Nives

    2016-02-01

    The purpose of this study was to evaluate the prevalence of Legionella spp. and compare the quality of hot water between four facilities for accommodation located in Southern Croatia (the Split-Dalmatian County). The research included data collection on the technical and technological characteristics in the period from 2009 to 2012. The survey included a type of construction material for the distribution and internal networks, heating system water heater type, and water consumption. Changes in water quality were monitored by determination of the physical and chemical parameters (temperature, pH, free chlorine residual concentrations, iron, zinc, copper and manganese) in the samples, as well as the presence and concentration of bacteria Legionella spp. The temperature is an important factor for the development of biofilms, and it is in negative correlation with the appearance of Legionella spp. Positive correlations between the Fe and Zn concentrations and Legionella spp. were established, while the inhibitory effect of a higher Cu concentration on the Legionella spp. concentration was proven. Legionella spp. were identified in 38/126 (30.2%) of the water samples from the heating system with zinc-coated pipes, as well as in 78/299 (26.1%) of the samples from systems with plastic pipes. A similar number of Legionella spp. positive samples were established regardless of the type of the water heating system (central or independent). The study confirms the necessity of regular microbial contamination monitoring of the drinking water distribution systems (DWDSs).

  13. Method and system for determining depth distribution of radiation-emitting material located in a source medium and radiation detector system for use therein

    DOEpatents

    Benke, Roland R.; Kearfott, Kimberlee J.; McGregor, Douglas S.

    2003-03-04

    A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The collimator may be a hollow cylinder positioned so that its central axis is perpendicular to the upper surface of the large area source when positioned thereon. The collimator allows the detector to angularly sample the emitted radiation over many ranges of polar angles. This is done by forming the collimator as a single adjustable collimator or a set of collimator pieces having various possible configurations when connected together. In any one configuration, the collimator allows the detector to detect only the radiation emitted from a selected range of polar angles measured from the detector axis. Adjustment of the collimator or the detector therein enables the detector to detect radiation emitted from a different range of polar angles. The system further includes a signal processor for processing the signals from the detector wherein signals obtained from different ranges of polar angles are processed together to obtain a reconstruction of the radiation-emitting material as a function of depth, assuming, but not limited to, a spatially-uniform depth distribution of the material within each layer. The detector system includes detectors having different properties (sensitivity, energy resolution) which are combined so that excellent spectral information may be obtained along with good determinations of the radiation field as a function of position.

  14. KS-Detect – Validation of Solar Thermal PCR for the Diagnosis of Kaposi’s Sarcoma Using Pseudo-Biopsy Samples

    PubMed Central

    Snodgrass, Ryan; Gardner, Andrea; Jiang, Li; Fu, Cheng; Cesarman, Ethel; Erickson, David

    2016-01-01

    Resource-limited settings present unique engineering challenges for medical diagnostics. Diagnosis is often needed for those unable to reach central healthcare systems, making portability and independence from traditional energy infrastructure essential device parameters. In 2014, our group presented a microfluidic device that performed a solar-powered variant of the polymerase chain reaction, which we called solar thermal PCR. In this work, we expand on our previous effort by presenting an integrated, portable, solar thermal PCR system targeted towards the diagnosis of Kaposi’s sarcoma. We call this system KS-Detect, and we now report the system’s performance as a diagnostic tool using pseudo-biopsy samples made from varying concentrations of human lymphoma cell lines positive for the KS herpesvirus (KSHV). KS-Detect achieved 83% sensitivity and 70% specificity at high (≥10%) KSHV+ cell concentrations when diagnosing pseudo-biopsy samples by smartphone image. Using histology, we confirm that our prepared pseudo-biopsies contain similar KSHV+ cell concentrations as human biopsies positive for KS. Through our testing of samples derived from human cell lines, we validate KS-Detect as a viable, portable KS diagnostic tool, and we identify critical engineering considerations for future solar-thermal PCR devices. PMID:26799834

  15. Occurrence of Legionella in showers at recreational facilities.

    PubMed

    De Filippis, Patrizia; Mozzetti, Cinzia; Amicosante, Massimo; D'Alò, Gian Loreto; Messina, Alessandra; Varrenti, Donatella; Giammattei, Roberto; Di Giorgio, Floriana; Corradi, Stefania; D'Auria, Alberto; Fraietta, Roberta; Gabrieli, Rosanna

    2017-06-01

    Critical environments, including water systems in recreational settings, represent an important source of Legionella pneumophila infection in humans. In order to assess the potential risk for legionellosis, we analyzed Legionella contamination of water distribution systems in 36 recreational facilities equipped with swimming pools. One hundred and sixty water samples were analyzed from shower heads or taps located in locker rooms or in bathrooms. By culture method and polymerase chain reaction, 41/160 samples were positive for Legionella from 12/36 recreational centers. Hotels (57.1%) and sports centers (41.2%) were the most contaminated. L. pneumophila serotypes 2-14 (25/41) were more frequently found than serotype 1 (10/41). Samples at temperature ≥30 °C were more frequently positive than samples at temperature <30 °C (n = 39 vs n = 2, p < 0.00001). The presence of L. pneumophila was investigated by comparison with heterotrophic plate count (HPC), an indicator of water quality. The presence of L. pneumophila was associated more frequently with high and intermediate HPC load at 37 °C, therefore should be considered a potential source when HPC at 37 °C is >10 CFU/mL. Maintenance, good hygiene practices, interventions on the hydraulic system and regular controls must be implemented to minimize exposure to L. pneumophila infection risk.

  16. Numerical modelling of needle-grid electrodes for negative surface corona charging system

    NASA Astrophysics Data System (ADS)

    Zhuang, Y.; Chen, G.; Rotaru, M.

    2011-08-01

    Surface potential decay measurement is a simple and low cost tool to examine electrical properties of insulation materials. During the corona charging stage, a needle-grid electrodes system is often used to achieve uniform charge distribution on the surface of the sample. In this paper, a model using COMSOL Multiphysics has been developed to simulate the gas discharge. A well-known hydrodynamic drift-diffusion model was used. The model consists of a set of continuity equations accounting for the movement, generation and loss of charge carriers (electrons, positive and negative ions) coupled with Poisson's equation to take into account the effect of space and surface charges on the electric field. Four models with the grid electrode in different positions and several mesh sizes are compared with a model that only has the needle electrode. The results for impulse current and surface charge density on the sample clearly show the effect of the extra grid electrode with various positions.

  17. Polymerase chain reaction system using magnetic beads for analyzing a sample that includes nucleic acid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nasarabadi, Shanavaz

    2011-01-11

    A polymerase chain reaction system for analyzing a sample containing nucleic acid includes providing magnetic beads; providing a flow channel having a polymerase chain reaction chamber, a pre polymerase chain reaction magnet position adjacent the polymerase chain reaction chamber, and a post pre polymerase magnet position adjacent the polymerase chain reaction chamber. The nucleic acid is bound to the magnetic beads. The magnetic beads with the nucleic acid flow to the pre polymerase chain reaction magnet position in the flow channel. The magnetic beads and the nucleic acid are washed with ethanol. The nucleic acid in the polymerase chain reactionmore » chamber is amplified. The magnetic beads and the nucleic acid are separated into a waste stream containing the magnetic beads and a post polymerase chain reaction mix containing the nucleic acid. The reaction mix containing the nucleic acid flows to an analysis unit in the channel for analysis.« less

  18. Monitoring the Presence of 13 Active Compounds in Surface Water Collected from Rural Areas in Northwestern Spain

    PubMed Central

    Iglesias, Alejandra; Nebot, Carolina; Vázquez, Beatriz I.; Coronel-Olivares, Claudia; Franco Abuín, Carlos M.; Cepeda, Alberto

    2014-01-01

    Drug residues are considered environmental contaminants, and their occurrence has recently become a matter of concern. Analytical methods and monitoring systems are therefore required to control the continuous input of these drug residues into the environment. This article presents a suitable HPLC-ESI-MS/MS method for the simultaneous extraction, detection and quantification of residues of 13 drugs (antimicrobials, glucocorticosteroids, anti-inflammatories, anti-hypertensives, anti-cancer drugs and triphenylmethane dyes) in surface water. A monitoring study with 549 water samples was carried out in northwestern Spain to detect the presence of drug residues over two sampling periods during 2010, 2011 and 2012. Samples were collected from rural areas with and without farming activity and from urban areas. The 13 analytes were detected, and 18% of the samples collected showed positive results for the presence of at least one analyte. More collection sites were located in rural areas than in urban areas. However, more positive samples with higher concentrations and a larger number of analytes were detected in samples collected from sites located after the discharge of a WWTP. Results indicated that the WWTPs seems to act as a concentration point. Positive samples were also detected at a site located near a drinking water treatment plant. PMID:24837665

  19. Monitoring the presence of 13 active compounds in surface water collected from rural areas in northwestern Spain.

    PubMed

    Iglesias, Alejandra; Nebot, Carolina; Vázquez, Beatriz I; Coronel-Olivares, Claudia; Abuín, Carlos M Franco; Cepeda, Alberto

    2014-05-15

    Drug residues are considered environmental contaminants, and their occurrence has recently become a matter of concern. Analytical methods and monitoring systems are therefore required to control the continuous input of these drug residues into the environment. This article presents a suitable HPLC-ESI-MS/MS method for the simultaneous extraction, detection and quantification of residues of 13 drugs (antimicrobials, glucocorticosteroids, anti-inflammatories, anti-hypertensives, anti-cancer drugs and triphenylmethane dyes) in surface water. A monitoring study with 549 water samples was carried out in northwestern Spain to detect the presence of drug residues over two sampling periods during 2010, 2011 and 2012. Samples were collected from rural areas with and without farming activity and from urban areas. The 13 analytes were detected, and 18% of the samples collected showed positive results for the presence of at least one analyte. More collection sites were located in rural areas than in urban areas. However, more positive samples with higher concentrations and a larger number of analytes were detected in samples collected from sites located after the discharge of a WWTP. Results indicated that the WWTPs seems to act as a concentration point. Positive samples were also detected at a site located near a drinking water treatment plant.

  20. Lipolytic and proteolytic activity of Pseudomonas spp. isolated during milking and storage of refrigerated raw milk.

    PubMed

    Capodifoglio, Eduardo; Vidal, Ana Maria Centola; Lima, Joyce Aparecida Santos; Bortoletto, Fernanda; D'Abreu, Léa Furlan; Gonçalves, Ana Carolina Siqueira; Vaz, Andreia Cristina Nakashima; Balieiro, Julio Cesar de Carvalho; Netto, Arlindo Saran

    2016-07-01

    The aim of this study was to verify the presence of lipolytic and proteolytic Pseudomonas spp. during milking and storage of refrigerated raw milk. We also intended to compare samples collected during rainy and dry seasons, from farms with manual and mechanical milking systems. For this, samples of milkers' hands, cows' teats, water, expansion tanks, equipment, and utensils used during milking were analyzed regarding Pseudomonas spp. Positive samples were tested for the production of lipolytic and proteolytic enzymes. Microorganisms of the genus Pseudomonas were isolated from all sampling points. A higher isolation rate of the bacterium was found in the rainy season except for 6 sampling points, with all of these associated with mechanical milking systems. Pseudomonas spp. exhibiting lipolytic activity were found to be predominant during the dry season, since no activity was detected during the rainy season in 26 of the 29 sampling sites. The highest number of lipolytic Pseudomonas isolates was obtained from water. Presence of lipase-producing Pseudomonas spp. was verified in 7 and 36% of the samples collected from farms with manual and mechanical milking, respectively. When analyzing raw milk collected from expansion tanks immediately (0 h) and 24h after milking, we observed that for dairy properties with manual milking process, 10% of the Pseudomonas isolates were positive for lipolytic activity. The percentage increased to 12% 48h after milking. Mean averages were 32, 33, and 39% immediately after, 24 and 48h after milking, respectively, for farms with mechanical milking. All sampling points showed the presence of proteolytic strains of Pseudomonas. The highest proteolytic activity was found during the rainy season, except for the samples collected from milkers' hands before milking, buckets, and teat cup inner surfaces after milking and from the water in dairy farms with mechanical milking system. Of these samples, 72, 56, and 50%, respectively, were positive for proteolysis during the dry season. For the water samples, a statistical difference was observed between mechanical (50%) and manual (7%) milking systems in the percentage of proteolytic activity. No production of proteolytic enzyme was detected in the samples from milkers' hands taken after milking and no statistically significant difference was found among manual (19.91%) and mechanical (47.85%) milking. During the rainy months, no proteolysis was detected in the samples taken from cows' teats after the predipping. It is evident, therefore, that preventive measures capable of minimizing the contamination with Pseudomonas spp. during milking and storage of refrigerated raw milk are needed, regardless of season. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  1. An Optical Sensor for Measuring the Position and Slanting Direction of Flat Surfaces

    PubMed Central

    Chen, Yu-Ta; Huang, Yen-Sheng; Liu, Chien-Sheng

    2016-01-01

    Automated optical inspection is a very important technique. For this reason, this study proposes an optical non-contact slanting surface measuring system. The essential features of the measurement system are obtained through simulations using the optical design software Zemax. The actual propagation of laser beams within the measurement system is traced by using a homogeneous transformation matrix (HTM), the skew-ray tracing method, and a first-order Taylor series expansion. Additionally, a complete mathematical model that describes the variations in light spots on photoelectric sensors and the corresponding changes in the sample orientation and distance was established. Finally, a laboratory prototype system was constructed on an optical bench to verify experimentally the proposed system. This measurement system can simultaneously detect the slanting angles (x, z) in the x and z directions of the sample and the distance (y) between the biconvex lens and the flat sample surface. PMID:27409619

  2. An Optical Sensor for Measuring the Position and Slanting Direction of Flat Surfaces.

    PubMed

    Chen, Yu-Ta; Huang, Yen-Sheng; Liu, Chien-Sheng

    2016-07-09

    Automated optical inspection is a very important technique. For this reason, this study proposes an optical non-contact slanting surface measuring system. The essential features of the measurement system are obtained through simulations using the optical design software Zemax. The actual propagation of laser beams within the measurement system is traced by using a homogeneous transformation matrix (HTM), the skew-ray tracing method, and a first-order Taylor series expansion. Additionally, a complete mathematical model that describes the variations in light spots on photoelectric sensors and the corresponding changes in the sample orientation and distance was established. Finally, a laboratory prototype system was constructed on an optical bench to verify experimentally the proposed system. This measurement system can simultaneously detect the slanting angles (x, z) in the x and z directions of the sample and the distance (y) between the biconvex lens and the flat sample surface.

  3. Guidelines for the use and interpretation of nucleic acid detection tests for Neisseria gonorrhoeae in Australia: a position paper on behalf of the Public Health Laboratory Network.

    PubMed

    Smith, David W; Tapsall, John W; Lum, Gary

    2005-01-01

    The Public Health Laboratory Network (PHLN) convened a workshop of Australian experts in Melbourne on 23 March 2005 to identify laboratory issues of relevance and suggest guidelines for use of nucleic acid detection tests (NADT) for diagnosis of gonorrhoea in Australia. The proceedings of that meeting were endorsed by the members of the PHLN and the Communicable Diseases Network of Australia. Given the present state of knowledge and experience of conditions currently existing in Australia, the following recommendations were made: Recommendation 1: Assays using detection of the cppB gene should not be used for either screening or supplemental assays. Recommendation 2: All in-house screening assays that are positive should also be positive on a reliable supplemental assay before a positive result is reported. Recommendation 3: All commercial screening assays that are positive should also be positive on a reliable supplemental assay before a positive result is reported. Recommendation 4: If a sample is positive in a screening assay but a suitable supplemental assay is negative, then the result should be reported as negative. Recommendation 5: Laboratories should ensure that the test combination they use would yield a positive predictive value of at least 90 per cent in a population with a prevalence of 1 per cent. Recommendation 6: For the purposes of test evaluation, as distinct from diagnostic testing, true positives be defined by meeting one or more of the following criteria: 1) culture positive using contemporary isolation and identification techniques; 2) positive result on NADTs directed to targets on three separate genes that are known to have discriminatory capacity; 3) sequencing of a gene known to separate gonococcal from non-gonococcal species. Recommendation 7: Inhibitor controls should be routinely included in all NADT. Recommendation 8: Cultures are the preferred test for samples from non-genital sites. If however it is necessary to perform a NADT, then more stringent criteria should be applied, and positive samples should meet the 'test evaluation' criteria for a 'true positive'. Recommendation 9: In order to properly assess the routine diagnostic system in Australia, the following quality assurance samples should be distributed in addition to the routine samples currently used: 1. cppB negative N. gonorrhoeae; 2. Non-gonococcal species known to cause false positive reactions: these should be dispatched both as a single species, as well as mixture with N. gonorrhoeae. In the latter circumstance, the non-gonococcal species should be present in 10-fold excess; 3. Urine samples: preferably a single patient sample, otherwise a spiked sample. 4. Validation panels should be made that include samples that are culture positive but PCR negative. True positive samples should also be made available. In addition, a process should be established for full phenotypic and genotypic characterisation of unidentified species that yield false positive results in NADT for gonococci. Recommendation 10: Strategies should be put in place to ensure that sufficient numbers of gonococcal isolates are obtained to allow reliable monitoring of antimicrobial resistance. Recommendation 11: Public health practitioners need to define the relevant populations that need to be targeted and identify any that require enhanced surveillance.

  4. A vision-based end-point control for a two-link flexible manipulator. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Obergfell, Klaus

    1991-01-01

    The measurement and control of the end-effector position of a large two-link flexible manipulator are investigated. The system implementation is described and an initial algorithm for static end-point positioning is discussed. Most existing robots are controlled through independent joint controllers, while the end-effector position is estimated from the joint positions using a kinematic relation. End-point position feedback can be used to compensate for uncertainty and structural deflections. Such feedback is especially important for flexible robots. Computer vision is utilized to obtain end-point position measurements. A look-and-move control structure alleviates the disadvantages of the slow and variable computer vision sampling frequency. This control structure consists of an inner joint-based loop and an outer vision-based loop. A static positioning algorithm was implemented and experimentally verified. This algorithm utilizes the manipulator Jacobian to transform a tip position error to a joint error. The joint error is then used to give a new reference input to the joint controller. The convergence of the algorithm is demonstrated experimentally under payload variation. A Landmark Tracking System (Dickerson, et al 1990) is used for vision-based end-point measurements. This system was modified and tested. A real-time control system was implemented on a PC and interfaced with the vision system and the robot.

  5. Usefulness of real-time PCR as a complementary tool to the monitoring of Legionella spp. and Legionella pneumophila by culture in industrial cooling systems.

    PubMed

    Touron-Bodilis, A; Pougnard, C; Frenkiel-Lebossé, H; Hallier-Soulier, S

    2011-08-01

    This study was designed to evaluate the usefulness of quantification by real-time PCR as a management tool to monitor concentrations of Legionella spp. and Legionella pneumophila in industrial cooling systems and its ability to anticipate culture trends by the French standard method (AFNOR T90-431). Quantifications of Legionella bacteria were achieved by both methods on samples from nine cooling systems with different water qualities. Proportion of positive samples for L. pneumophila quantified by PCR was clearly lower in deionized or river waters submitted to a biocide treatment than in raw river waters, while positive samples for Legionella spp. were quantified for almost all the samples. For some samples containing PCR inhibitors, high quantification limits (up to 4·80 × 10(5) GU l(-1) ) did not allow us to quantify L. pneumophila, when they were quantified by culture. Finally, the monitoring of concentrations of L. pneumophila by both methods showed similar trends for 57-100% of the samples. These results suggest that, if some methodological steps designed to reduce inhibitory problems and thus decrease the quantification limits, could be developed to quantify Legionella in complex waters, the real-time PCR could be a valuable complementary tool to monitor the evolution of L. pneumophila concentrations. This study shows the possibility of using real-time PCR to monitor L. pneumophila proliferations in cooling systems and the importance to adapt nucleic acid extraction and purification protocols to raw waters. Journal of Applied Microbiology © 2011 The Society for Applied Microbiology. No claim to French Government works.

  6. Development and performance evaluation of a three-dimensional clinostat synchronized heavy-ion irradiation system.

    PubMed

    Ikeda, Hiroko; Souda, Hikaru; Puspitasari, Anggraeini; Held, Kathryn D; Hidema, Jun; Nikawa, Takeshi; Yoshida, Yukari; Kanai, Tatsuaki; Takahashi, Akihisa

    2017-02-01

    Outer space is an environment characterized by microgravity and space radiation, including high-energy charged particles. Astronauts are constantly exposed to both microgravity and radiation during long-term stays in space. However, many aspects of the biological effects of combined microgravity and space radiation remain unclear. We developed a new three-dimensional (3D) clinostat synchronized heavy-ion irradiation system for use in ground-based studies of the combined exposures. Our new system uses a particle accelerator and a respiratory gating system from heavy-ion radiotherapy to irradiate samples being rotated in the 3D clinostat with carbon-ion beams only when the samples are in the horizontal position. A Peltier module and special sample holder were loaded on a static stage (standing condition) and the 3D clinostat (rotation condition) to maintain a suitable temperature under atmospheric conditions. The performance of the new device was investigated with normal human fibroblasts 1BR-hTERT in a disposable closed cell culture chamber. Live imaging revealed that cellular adhesion and growth were almost the same for the standing control sample and rotation sample over 48h. Dose flatness and symmetry were judged according to the relative density of Gafchromic films along the X-axis and Y-axis of the positions of the irradiated sample to confirm irradiation accuracy. Doses calculated using the carbon-ion calibration curve were almost the same for standing and rotation conditions, with the difference being less than 5% at 1Gy carbon-ion irradiation. Our new device can accurately synchronize carbon-ion irradiation and simulated microgravity while maintaining the temperature under atmospheric conditions at ground level. Copyright © 2017 The Committee on Space Research (COSPAR). Published by Elsevier Ltd. All rights reserved.

  7. Tests of positive ion beams from a microwave ion source for AMS

    NASA Astrophysics Data System (ADS)

    Schneider, R. J.; von Reden, K. F.; Hayes, J. M.; Wills, J. S. C.; Kern, W. G. E.; Kim, S.-W.

    2000-10-01

    A test facility has been constructed to evaluate high-current positive ion beams from small gaseous samples for AMS applications. The major components include a compact permanent magnet microwave ion source built at the AECL Chalk River Laboratory and now on loan from the University of Toronto, and a double-focusing spectrometer magnet on loan from Argonne National Laboratory. Samples are introduced by means of a silica capillary injection system. Loop injection into a carrier gas provides a stable feed for the microwave driven plasma. The magnetic analysis system is utilized to isolate carbon ions derived from CO 2 samples from other products of the plasma discharge, including argon ions of the carrier gas. With a smaller discharge chamber, we hope to exceed a conversion efficiency of 14% for carbon ions produced per atom, which we reported at AMS-7. The next step will be to construct an efficient charge-exchange cell, to produce negative ions for injection into the WHOI recombinator injector.

  8. Activity and Phylogenetic Diversity of Bacterial Cells with High and Low Nucleic Acid Content and Electron Transport System Activity in an Upwelling Ecosystem

    PubMed Central

    Longnecker, K.; Sherr, B. F.; Sherr, E. B.

    2005-01-01

    We evaluated whether bacteria with higher cell-specific nucleic acid content (HNA) or an active electron transport system, i.e., positive for reduction of 5-cyano-2,3-ditolyl tetrazolium chloride (CTC), were responsible for the bulk of bacterioplankton metabolic activity. We also examined whether the phylogenetic diversity of HNA and CTC-positive cells differed from the diversity of Bacteria with low nucleic acid content (LNA). Bacterial assemblages were sampled both in eutrophic shelf waters and in mesotrophic offshore waters in the Oregon coastal upwelling region. Cytometrically sorted HNA, LNA, and CTC-positive cells were assayed for their cell-specific [3H]leucine incorporation rates. Phylogenetic diversity in sorted non-radioactively labeled samples was assayed using denaturing gradient gel electrophoresis (DGGE) of PCR-amplified 16S rRNA genes. Cell-specific rates of leucine incorporation of HNA and CTC-positive cells were on average only slightly greater than the cell-specific rates of LNA cells. HNA cells accounted for most bacterioplankton substrate incorporation due to high abundances, while the low abundances of CTC-positive cells resulted in only a small contribution by these cells to total bacterial activity. The proportion of the total bacterial leucine incorporation attributable to LNA cells was higher in offshore regions than in shelf waters. Sequence data obtained from DGGE bands showed broadly similar phylogenetic diversity across HNA, LNA, and CTC-positive cells, with between-sample and between-region variability in the distribution of phylotypes. Our results suggest that LNA bacteria are not substantially different from HNA bacteria in either cell-specific rates of substrate incorporation or phylogenetic composition and that they can be significant contributors to bacterial metabolism in the sea. PMID:16332746

  9. Activity and phylogenetic diversity of bacterial cells with high and low nucleic acid content and electron transport system activity in an upwelling ecosystem.

    PubMed

    Longnecker, K; Sherr, B F; Sherr, E B

    2005-12-01

    We evaluated whether bacteria with higher cell-specific nucleic acid content (HNA) or an active electron transport system, i.e., positive for reduction of 5-cyano-2,3-ditolyl tetrazolium chloride (CTC), were responsible for the bulk of bacterioplankton metabolic activity. We also examined whether the phylogenetic diversity of HNA and CTC-positive cells differed from the diversity of Bacteria with low nucleic acid content (LNA). Bacterial assemblages were sampled both in eutrophic shelf waters and in mesotrophic offshore waters in the Oregon coastal upwelling region. Cytometrically sorted HNA, LNA, and CTC-positive cells were assayed for their cell-specific [3H]leucine incorporation rates. Phylogenetic diversity in sorted non-radioactively labeled samples was assayed using denaturing gradient gel electrophoresis (DGGE) of PCR-amplified 16S rRNA genes. Cell-specific rates of leucine incorporation of HNA and CTC-positive cells were on average only slightly greater than the cell-specific rates of LNA cells. HNA cells accounted for most bacterioplankton substrate incorporation due to high abundances, while the low abundances of CTC-positive cells resulted in only a small contribution by these cells to total bacterial activity. The proportion of the total bacterial leucine incorporation attributable to LNA cells was higher in offshore regions than in shelf waters. Sequence data obtained from DGGE bands showed broadly similar phylogenetic diversity across HNA, LNA, and CTC-positive cells, with between-sample and between-region variability in the distribution of phylotypes. Our results suggest that LNA bacteria are not substantially different from HNA bacteria in either cell-specific rates of substrate incorporation or phylogenetic composition and that they can be significant contributors to bacterial metabolism in the sea.

  10. Restricted Boltzmann machines based oversampling and semi-supervised learning for false positive reduction in breast CAD.

    PubMed

    Cao, Peng; Liu, Xiaoli; Bao, Hang; Yang, Jinzhu; Zhao, Dazhe

    2015-01-01

    The false-positive reduction (FPR) is a crucial step in the computer aided detection system for the breast. The issues of imbalanced data distribution and the limitation of labeled samples complicate the classification procedure. To overcome these challenges, we propose oversampling and semi-supervised learning methods based on the restricted Boltzmann machines (RBMs) to solve the classification of imbalanced data with a few labeled samples. To evaluate the proposed method, we conducted a comprehensive performance study and compared its results with the commonly used techniques. Experiments on benchmark dataset of DDSM demonstrate the effectiveness of the RBMs based oversampling and semi-supervised learning method in terms of geometric mean (G-mean) for false positive reduction in Breast CAD.

  11. Microbial Load Monitor

    NASA Technical Reports Server (NTRS)

    Gibson, S. F.; Royer, E. R.

    1979-01-01

    The Microbial Load Monitor (MLM) is an automated and computerized system for detection and identification of microorganisms. Additionally, the system is designed to enumerate and provide antimicrobic susceptibility profiles for medically significant bacteria. The system is designed to accomplish these tasks in a time of 13 hours or less versus the traditional time of 24 hours for negatives and 72 hours or more for positives usually required for standard microbiological analysis. The MLM concept differs from other methods of microbial detection in that the system is designed to accept raw untreated clinical samples and to selectively identify each group or species that may be present in a polymicrobic sample.

  12. Effectiveness of computer-aided diagnosis (CADx) of breast pathology using immunohistochemistry results of core needle biopsy samples for synaptophysin, oestrogen receptor and CK14/p63 for classification of epithelial proliferative lesions of the breast.

    PubMed

    Maeda, Ichiro; Kubota, Manabu; Ohta, Jiro; Shinno, Kimika; Tajima, Shinya; Ariizumi, Yasushi; Doi, Masatomo; Oana, Yoshiyasu; Kanemaki, Yoshihide; Tsugawa, Koichiro; Ueno, Takahiko; Takagi, Masayuki

    2017-12-01

    The aim of this study was to develop a computer-aided diagnosis (CADx) system for identifying breast pathology. Two sets of 100 consecutive core needle biopsy (CNB) specimens were collected for test and validation studies. All 200 CNB specimens were stained with antibodies targeting oestrogen receptor (ER), synaptophysin and CK14/p63. All stained slides were scanned in a whole-slide imaging system and photographed. The photographs were analysed using software to identify the proportions of tumour cells that were positive and negative for each marker. In the test study, the cut-off values for synaptophysin (negative and positive) and CK14/p63 (negative and positive) were decided using receiver operating characteristic (ROC) analysis. For ER analysis, samples were divided into groups with <10% positive or >10% positive cells and decided using receiver operating characteristic (ROC) analysis. Finally, these two groups categorised as ER-low, ER-intermediate (non-low and non-high) and ER-high groups. In the validation study, the second set of immunohistochemical slides were analysed using these cut-off values. The cut-off values for synaptophysin, <10% ER positive, >10% ER positive and CK14/p63 were 0.14%, 2.17%, 77.93% and 18.66%, respectively. The positive predictive value for malignancy (PPV) was 100% for synaptophysin-positive/ER-high/(CK14/p63)-any or synaptophysin-positive/ER-low/(CK14/p63)-any. The PPV was 25% for synaptophysin-positive/ER-intermediate/(CK14/p63)-positive. For synaptophysin-negative/(CK14/p63)-negative, the PPVs for ER-low, ER-intermediate and ER-high were 100%, 80.0% and 95.8%, respectively. The PPV was 4.5% for synaptophysin-negative/ER-intermediate/(CK14/p63)-positive. The CADx system was able to analyse sufficient data for all types of epithelial proliferative lesions of the breast including invasive breast cancer. This system may be useful for pathological diagnosis of breast CNB in routine investigations. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. HPV detection rate in saliva may depend on the immune system efficiency.

    PubMed

    Adamopoulou, Maria; Vairaktaris, Eleftherios; Panis, Vassilis; Nkenke, Emeka; Neukam, Friedreich W; Yapijakis, Christos

    2008-01-01

    Human papilloma virus (HPV) has been established as a major etiological factor of anogenital cancer. In addition, HPV has also been implicated in oral carcinogenesis but its detection rates appear to be highly variable, depending on the patient population tested, the molecular methodology used, as well as the type of oral specimen investigated. For example, saliva is an oral fluid that may play a role in HPV transmission, although the detection rates of the virus are lower than tissue. Recent evidence has indicated that HPV-related pathology is increased in the oral cavity of human immunodeficiency virus (HIV)-positive individuals. In order to investigate whether the presence of different HPV types in saliva depends on immune system efficiency, oral fluid samples of patients with oral cancer and without any known immune deficiency were compared with those of HIV-positive individuals. Saliva samples were collected from 68 patients with oral squamous cell carcinoma and 34 HIV seropositive individuals. HPV DNA sequences were detected by L1 concensus polymerase chain reaction (PCR), followed by restriction fragment length polymorphism (RFLP) analysis and DNA sequencing for HPV typing. HPV DNA was detected in 7/68 (10.3%) of the oral cancer patients and in 12/34 (35.3%) of the HIV-positive individuals, a highly significant difference (p = 0.006; odds ratio 4.753; 95% confidence interval 1.698-13.271). Among HPV-positive samples, the prevalence of HPV types associated with high oncogenic risk was similar in oral cancer and HIV-positive cases (71.4% and 66.7%, respectively). In both groups, the most common HPV type was high-risk 16 (50% and 42.8%, respectively). Although a similar pattern of HPV high-risk types was detected in oral cancer and HIV-positive cases, the quantitative detection of HPV in saliva significantly depended on immune system efficiency. Furthermore, the significantly increased detection rates of HPV in saliva of HIV-positive individuals may be associated with high risk for development of HPV-related oral lesions, including malignancy.

  14. Feasibility study of contaminant detection for food with ULF-NMR/MRI system using HTS-SQUID

    NASA Astrophysics Data System (ADS)

    Hatsukade, Yoshimi; Tsunaki, Shingo; Yamamoto, Masaaki; Abe, Takayuki; Hatta, Junichi; Tanaka, Saburo

    2013-11-01

    We have developed an ultra-low frequency (ULF) nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) system utilizing an HTS-SQUID for an application of contaminant detection in food and drink. In the system, a permanent magnet of 1.1 T was used to pre-polarize protons in a water sample. We measured NMR signals from water samples with or without various contaminants, such as stainless steel (SUS304), aluminum, and glass balls using the system. In the case that the contaminant was the SUS304 ball, the NMR signal intensity was reduced compared to that from the sample without the contaminant due to the remnant field of the contaminant. One-dimensional (1D) MRIs of the samples were also acquired to detect non-magnetic contaminants. In the 1D MRIs, changes of the MRI spectra were detected, corresponding to positions of the contaminants. These results show that the feasibility of the system to detect various contaminants in foods.

  15. Rapid sample classification using an open port sampling interface coupled with liquid introduction atmospheric pressure ionization mass spectrometry

    DOE PAGES

    Van Berkel, Gary J.; Kertesz, Vilmos

    2016-11-15

    An “Open Access”-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendorprovided software libraries. Sample classification based on spectral comparison utilized themore » spectral contrast angle method. As a result, using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. In conclusion, this work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching.« less

  16. Rapid sample classification using an open port sampling interface coupled with liquid introduction atmospheric pressure ionization mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Berkel, Gary J.; Kertesz, Vilmos

    An “Open Access”-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendorprovided software libraries. Sample classification based on spectral comparison utilized themore » spectral contrast angle method. As a result, using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. In conclusion, this work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching.« less

  17. Sampling probe for microarray read out using electrospray mass spectrometry

    DOEpatents

    Van Berkel, Gary J.

    2004-10-12

    An automated electrospray based sampling system and method for analysis obtains samples from surface array spots having analytes. The system includes at least one probe, the probe including an inlet for flowing at least one eluting solvent to respective ones of a plurality of spots and an outlet for directing the analyte away from the spots. An automatic positioning system is provided for translating the probe relative to the spots to permit sampling of any spot. An electrospray ion source having an input fluidicly connected to the probe receives the analyte and generates ions from the analyte. The ion source provides the generated ions to a structure for analysis to identify the analyte, preferably being a mass spectrometer. The probe can be a surface contact probe, where the probe forms an enclosing seal along the periphery of the array spot surface.

  18. Environmental factors and chemical and microbiological water-quality constituents related to the presence of enteric viruses in ground water from small public water supplies in southeastern Michigan

    USGS Publications Warehouse

    Francy, Donna S.; Bushon, Rebecca N.; Stopar, Julie; Luzano, Emma J.; Fout, G. Shay

    2004-01-01

    A study of small public ground-water-supply wells that produce water from discontinuous sand and gravel aquifers was done from July 1999 through July 2001 in southeastern Michigan. Samples were collected to determine the occurrence of viral pathogens and microbiological indicators of fecal contamination (indicators), determine whether indicators are adequate predictors of the presence of enteric viruses, and determine the factors that affect the presence of enteric viruses. Small systems are those that serve less than 3,300 people. Samples were analyzed for specific enteric viruses by reverse transcriptase-polymerase chain reaction (RT-PCR), for culturable viruses by cell culture, and for the indicators total coliforms, Escherichia coli (E. coli), enterococci, and F-specific and somatic coliphage. Ancillary environmental and water-quality data were collected or compiled. A total of 169 regular samples and 32 replicate pairs were collected from 38 wells. Replicate pairs were samples collected at the same well on the same date. One well was sampled 6 times, 30 wells were sampled five times, 6 wells were sampled twice, and 1 well was sampled once. By use of RT-PCR, enterovirus was found in four wells (10.5 percent) and hepatitis A virus (HAV) in five wells (13.2 percent). In two of these wells, investigators found both enterovirus and HAV, but on different sampling dates. Culturable viruses were found one time in two wells (5.9 percent), and neither of these wells was positive for viruses by use of RT-PCR on any sampling date. If results for all viruses are combined, 9 of the 38 small public-supply wells were positive for enteric viruses (23.7 percent) by either cell culture or RT-PCR. One or more indicators were found in 18 of 38 wells. Total coliforms, E. coli, enterococci, and F-specific and somatic coliphage were found in 34.2, 10.5, 15.8, 5.9, and 5.9 percent, respectively, of the wells tested. In only 3 out of 18 wells were samples positive for an indicator on more than one date at the same well. The co-occurrence of enteric viruses and any indicator was 55.6 percent; five out of the nine virus-positive wells were also found to be positive for an indicator. Two wells with detections of viruses had a detection of total coliforms, one well had a detection of E. coli, one of enterococci, and one of F-specific coliphage. On a per sample basis, of 11 samples that were positive for enteric viruses, indicator bacteria co-occurred in only 2 samples, and coliphage were not present in any. More virus-positive samples were found at sites served by septic systems than those served by sewerlines. Sampling condition (ground water or a mixture of tank and ground water), distance to septic system, type of and distance to nearest surface-water body, well characteristics, or land use were not related to the presence of viruses or indicators. Among continuous water-quality variables, statistically significant relations were found between total coliforms and dissolved organic carbon and between total coliforms and iron. There was a statistically significant relation between chloride concentrations >20 mg/L and detections of total coliforms. Presence of nitrate and nitrite was related to the presence of other indicators (E. coli, enterococci, and F-specific and somatic coliphage) or enteric viruses, but not to total coliforms. The data indicated that chloride-to-bromide (C1:Br) ratios may be useful as a screening tool for total coliforms and enteric viruses but not for E. coli, enterococci, and F-specific and somatic coliphage. This study provides evidence for fecal contamination of ground water from small public-supply wells, at least on an intermittent basis. Collecting data on multiple lines of evidence would be needed to reliably predict the presence of enteric viruses and protect public health. Future data collection toward this end could include repeat sampling several times a year for different indicators, measuring dissolv

  19. Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure using a laser sensor

    DOEpatents

    Van Berkel, Gary J [Clinton, TN; Kertesz, Vilmos [Knoxville, TN

    2012-02-21

    A system and method utilizes distance-measuring equipment including a laser sensor for controlling the collection instrument-to-surface distance during a sample collection process for use, for example, with mass spectrometric detection. The laser sensor is arranged in a fixed positional relationship with the collection instrument, and a signal is generated by way of the laser sensor which corresponds to the actual distance between the laser sensor and the surface. The actual distance between the laser sensor and the surface is compared to a target distance between the laser sensor and the surface when the collection instrument is arranged at a desired distance from the surface for sample collecting purposes, and adjustments are made, if necessary, so that the actual distance approaches the target distance.

  20. Diurnal Coupling between Testosterone and Cortisol from Adolescence to Older Adulthood

    PubMed Central

    Harden, K. Paige; Wrzus, Cornelia; Luong, Gloria; Grotzinger, Andrew; Bajbouj, Malek; Rauers, Antje; Wagner, Gert G.; Riediger, Michaela

    2016-01-01

    The hypothalamic-pituitary-adrenal (HPA) and hypothalamic-pituitary-gonadal (HPG) axes are typically conceptualized as mutually inhibitory systems; however, previous studies have found evidence for positive within-person associations (i.e., coupling) between cortisol and testosterone. One developmental hypothesis is that positive testosterone-cortisol coupling is unique to the adolescent period and that coupling becomes attenuated, or even switches direction, in adulthood. This study used a lifespan sample (N = 292, ages 11 to 88) to test for age-related differences in coupling between cortisol and testosterone in daily life. Participants provided salivary hormone samples at waking, 30 minutes after waking, and during the evening for two days. Hierarchical linear modeling was used to test the within-person and between-person associations between testosterone and cortisol. Within-person associations were further decomposed into associations due to coupled diurnal change versus coupled variability around diurnal change. Results indicated positive associations between cortisol and testosterone at all levels of analysis. Additionally, positive coupling was evident across the lifespan, even in older adults who are no longer expected to reproduce, but further investigation of developmental differences with a larger sample is necessary. Potential mechanisms and functions for positive coupling are discussed. PMID:27474909

  1. Automated Liquid Microjunction Surface Sampling-HPLC-MS/MS Analysis of Drugs and Metabolites in Whole-Body Thin Tissue Sections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kertesz, Vilmos; Van Berkel, Gary J

    A fully automated liquid extraction-based surface sampling system utilizing a commercially available autosampler coupled to high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) detection is reported. Discrete spots selected for droplet-based sampling and automated sample queue generation for both the autosampler and MS were enabled by using in-house developed software. In addition, co-registration of spatially resolved sampling position and HPLC-MS information to generate heatmaps of compounds monitored for subsequent data analysis was also available in the software. The system was evaluated with whole-body thin tissue sections from propranolol dosed rat. The hands-free operation of the system was demonstrated by creating heatmapsmore » of the parent drug and its hydroxypropranolol glucuronide metabolites with 1 mm resolution in the areas of interest. The sample throughput was approximately 5 min/sample defined by the time needed for chromatographic separation. The spatial distributions of both the drug and its metabolites were consistent with previous studies employing other liquid extraction-based surface sampling methodologies.« less

  2. Evaluation of human papillomavirus detection by Abbott m2000 system on samples collected by FTA Elute™ Card in a Chinese HIV-1 positive population.

    PubMed

    Qin, Yu; Zhang, Hongyun; Marlowe, Natalia; Fei, Mandong; Yu, Judy; Lei, Xiaoqin; Yu, Lulu; Zhang, Jia; Cao, Di; Ma, Li; Chen, Wen

    2016-12-01

    HIV+/AIDS women have an increased risk of developing into CIN and cervical cancer compared to the general population. Limited medical resource and the lack of AIDS relevant knowledge impair the coverage and efficiency of cervical cancer screening. To compare the clinical performance of self-collected dry storage medium (FTA Elute card) and physician-collected PreservCyt medium in detection of high risk human papillomavirus (HR HPV) among HIV-1 positive population. Three hundred HIV-1 positive women (aged 25-65) were recruited from Yunnan infectious hospital. Two cervicovaginal samples were collected from each participant: one was collected by the women themselves and applied on a FTA Elute card; the other one was collected by a physician and stored in PreservCyt solution. All the samples were tested for 14 HR HPV using Abbott RealTime High Risk HPV assay. Biopsies were taken for histological diagnosis if any abnormal impression was noticed under colposcopy. 291 (97.0%) of participants were eligible for this study. 101 (34.70%) participants were found HR HPV positive in both FTA card and PreservCyt samples, and 19 (6.53%) women were diagnosed as CIN2+. The HR HPV positive rate on samples collected by FTA Elute card and PreservCyt solution was 42.61% and 39.86%, respectively. The overall agreement was 87% (kappa=0.731) between FTA card and PreservCyt. The clinical sensitivity and specificity of FTA card and PreservCyt were 100%, 61.39% and 100%, 64.33%, respectively. In this study, FTA Elute card demonstrated a good performance on self-collected sample for HR HPV detection in HIV-1 positive population. For the women from low-resource area with HIV-1 infection, FTA Elute card could be an attractive sample collection method for cervical cancer screening. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Characterization of C/Enhanced SiC Composite During Creep-Rupture Tests Using an Ultrasonic Guided Wave Scan System

    NASA Technical Reports Server (NTRS)

    Roth, Don J.; Verrilli, Michael J.; Martin, Richard E.; Cosgriff, Laura M.

    2004-01-01

    An ultrasonic guided wave scan system was used to nondestructively monitor damage over time and position in a C/enhanced SiC sample that was creep tested to failure at 1200 C in air at a stress of 69 MPa (10 ksi). The use of the guided wave scan system for mapping evolving oxidation profiles (via porosity gradients resulting from oxidation) along the sample length and predicting failure location was explored. The creep-rupture tests were interrupted for ultrasonic evaluation every two hours until failure at approx. 17.5 cumulative hours.

  4. Effect of Foot Hyperpronation on Lumbar Lordosis and Thoracic Kyphosis in Standing Position Using 3-Dimensional Ultrasound-Based Motion Analysis System

    PubMed Central

    Farokhmanesh, Khatere; Shirzadian, Toraj; Mahboubi, Mohammad; Shahri, Mina Neyakan

    2014-01-01

    Based on clinical observations, foot hyperpronation is very common. Excessive pronation (hyperpronation) can cause malalignment of the lower extremities. This most often leads to functional and structural deficits. The aim of this study was to assess the effect of foot hyperpronation on lumbar lordosis and thoracic kyphosis. Thirty five healthy subjects (age range, 18030 years) were asked to stand on 4 positions including a flat surface (normal position) and on wedges angled at 10, 15, and 20 degrees. Sampling was done using simple random sampling. Measurements were made by a motion analysis system. For data analysis, the SPSS software (ver. 18) using paired t-test and repeated measures analysis of variance (ANOVA) was applied. The eversion created by the wedges caused a significant increase in lumbar lordosis and thoracic kyphosis. The most significant change occurred between two consecutive positions of flat surface and the first wedge. The t-test for repeated measures showed a high correlation between each two consecutive positions. The results showed that with increased bilateral foot pronation, lumbar lordosis and thoracic kyphosis increased as well. In fact, each of these results is a compensation phenomenon. Further studies are required to determine long-term results of excessive foot pronation and its probable effect on damage progression. PMID:25169004

  5. Effect of foot hyperpronation on lumbar lordosis and thoracic kyphosis in standing position using 3-dimensional ultrasound-based motion analysis system.

    PubMed

    Farokhmanesh, Khatere; Shirzadian, Toraj; Mahboubi, Mohammad; Shahri, Mina Neyakan

    2014-06-17

    Based on clinical observations, foot hyperpronation is very common. Excessive pronation (hyperpronation) can cause malalignment of the lower extremities. This most often leads to functional and structural deficits. The aim of this study was to assess the effect of foot hyperpronation on lumbar lordosis and thoracic kyphosis. Thirty five healthy subjects (age range, 18030 years) were asked to stand on 4 positions including a flat surface (normal position) and on wedges angled at 10, 15, and 20 degrees. Sampling was done using simple random sampling. Measurements were made by a motion analysis system. For data analysis, the SPSS software (ver. 18) using paired t-test and repeated measures analysis of variance (ANOVA) was applied. The eversion created by the wedges caused a significant increase in lumbar lordosis and thoracic kyphosis. The most significant change occurred between two consecutive positions of flat surface and the first wedge. The t-test for repeated measures showed a high correlation between each two consecutive positions. The results showed that with increased bilateral foot pronation, lumbar lordosis and thoracic kyphosis increased as well. In fact, each of these results is a compensation phenomenon. Further studies are required to determine long-term results of excessive foot pronation and its probable effect on damage progression.

  6. [Evaluation of viral etiology in central nervous system infections from a university hospital point of view in Izmir based on seven years data].

    PubMed

    Zeytinoğlu, Ayşın; Erensoy, Selda; Sertöz, Rüçhan; Altuğlu, İmre; Çiçek, Candan; Kayın, Münevver; Şirin, Hadiye; Taner, Şafak

    2017-04-01

    The serious diseases of the central nervous system (CNS); encephalitis and meningitis, have high mortality and morbidity rate especially not diagnosed and treated in time. Nucleic acid testing (NAT) is the tool of choice for viral diagnosis in CNS infections. In this study, viral etiological agents found in cerebrospinal fluid (CSF) samples sent to our university hospital virology laboratory for laboratory diagnosis of CNS infections were retrospectively evaluated and results were compared with other reports from our country. Viral etiological agents found in cerebrospinal fluid (CSF) samples sent to Ege University Faculty of Medicine Department of Medical Microbiology Virology Laboratories for laboratory diagnosis of CNS infection between 01.01.2009-31.12.2015 were evaluated retrospectively. A total of 3778 CSF tests were performed for cell culture of enterovirus (EV) in 487 samples and 3291 tests for nucleic acid testing (NAT) by real time polymerase chain reaction (PCR) in herpes simplex virus 1 (HSV1), herpes simplex virus 2 (HSV2), varicella zoster virus (VZV), Epstein-Barr virus (EBV), cytomegalovirus (CMV), human herpes virus 6 (HHV6) and EV. VZV and EV NAT's were performed during the last one and five years period, respectively. NAT positive results for HSV1, HSV2, CMV, EBV, VZV, HHV6 and EV were 1.80% (24/1333), 0.08% (1/1333), 3.28% (19/580), 4.35% (22/506), 0.46% (1/216), 1.05% (5/478) and 3.37% (6/178), respectively. EV was isolated in 30 (6.20%) of 487 CSF samples by viral culture. Positive samples were mainly from pediatric, neurology and infectious diseases clinics as expected. The number of higher positive results were found in samples sentin december (35.3%), july (12.9%) and november (10.6%). Overall 80% of positive samples belonged to patients over 18 years old. When the results of other studies reported from Turkey are examined, although the positivity rates are generally similar, it is seen that the rates specific to certain factors are higher in selected smaller patient groups like HSV1 and EV. Rapid nucleic acid tests like multiplex PCR and microarray will provide more practical and effective laboratory diagnosis approach in CNS infections, since many more microorganisms may be causative agents.

  7. Rapid and Accurate Diagnosis Based on Real-Time PCR Cycle Threshold Value for the Identification of Campylobacter jejuni, astA Gene-Positive Escherichia coli, and eae Gene-Positive E. coli.

    PubMed

    Kawase, Jun; Asakura, Hiroshi; Kurosaki, Morito; Oshiro, Hitoshi; Etoh, Yoshiki; Ikeda, Tetsuya; Watahiki, Masanori; Kameyama, Mitsuhiro; Hayashi, Fumi; Kawakami, Yuta; Murakami, Yoshiko; Tsunomori, Yoshie

    2018-01-23

    We previously developed a multiplex real-time PCR assay (Rapid Foodborne Bacterial Screening 24 ver.5, [RFBS24 ver.5]) for simultaneous detection of 24 foodborne bacterial targets. Here, to overcome the discrepancy of the results from RFBS24 ver.5 and bacterial culture methods (BC), we analyzed 246 human clinical samples from 49 gastroenteritis outbreaks using RFBS24 ver.5 and evaluated the correlation between the cycle threshold (CT) value of RFBS24 ver.5 and the BC results. The results showed that the RFBS24 ver.5 was more sensitive than BC for Campylobacter jejuni and Escherichia coli harboring astA or eae, with positive predictive values (PPV) of 45.5-87.0% and a kappa coefficient (KC) of 0.60-0.92, respectively. The CTs were significantly different between BC-positive and -negative samples (p < 0.01). All RFBS24 ver.5-positive samples were BC-positive under the lower confidence interval (CI) limit of 95% or 99% for the CT of the BC-negative samples. We set the 95% or 99% CI lower limit to the determination CT (d-CT) to discriminate for assured BC-positive results (d-CTs: 27.42-30.86), and subsequently the PPVs (94.7%-100.0%) and KCs (0.89-0.95) of the 3 targets were increased. Together, we concluded that the implication of a d-CT-based approach would be a valuable tool for rapid and accurate diagnoses using the RFBS24 ver.5 system.

  8. Practical continuous-variable quantum key distribution without finite sampling bandwidth effects.

    PubMed

    Li, Huasheng; Wang, Chao; Huang, Peng; Huang, Duan; Wang, Tao; Zeng, Guihua

    2016-09-05

    In a practical continuous-variable quantum key distribution system, finite sampling bandwidth of the employed analog-to-digital converter at the receiver's side may lead to inaccurate results of pulse peak sampling. Then, errors in the parameters estimation resulted. Subsequently, the system performance decreases and security loopholes are exposed to eavesdroppers. In this paper, we propose a novel data acquisition scheme which consists of two parts, i.e., a dynamic delay adjusting module and a statistical power feedback-control algorithm. The proposed scheme may improve dramatically the data acquisition precision of pulse peak sampling and remove the finite sampling bandwidth effects. Moreover, the optimal peak sampling position of a pulse signal can be dynamically calibrated through monitoring the change of the statistical power of the sampled data in the proposed scheme. This helps to resist against some practical attacks, such as the well-known local oscillator calibration attack.

  9. The Prompt Gamma Neutron Activation Analysis Facility at ICN—Pitesti

    NASA Astrophysics Data System (ADS)

    Bǎrbos, D.; Pǎunoiu, C.; Mladin, M.; Cosma, C.

    2008-08-01

    PGNAA is a very widely applicable technique for determining the presence and amount of many elements simultaneously in samples ranging in size from micrograms to many grams. PGNAA is characterized by its capability for nondestructive multi-elemental analysis and its ability to analyse elements that cannot be determined by INAA. By means of this PGNAA method we are able to increase the performace of INAA method. A facility has been developed at Institute for Nuclear Research—Piteşti so that the unique features of prompt gamma-ray neutron activation analysis can be used to measure trace and major elements in samples. The facility is linked at the radial neutron beam tube at ACPR-TRIGA reactor. During the PGNAA—facility is in use the ACPR reactor will be operated in steady-state mode at 250 KW maximum power. The facility consists of a radial beam-port, external sample position with shielding, and induced prompt gamma-ray counting system. Thermal neutron flux with energy lower than cadmium cut-off at the sample position was measured using thin gold foil is: φscd = 1.106 n/cm2/s with a cadmium ratio of:80. The gamma-ray detection system consist of an HpGe detector of 16% efficiency (detector model GC1518) with 1.85 keV resolution capability. The HpGe is mounted with its axis at 90° with respect to the incident neutron beam at distance about 200mm from the sample position. To establish the performance capabilities of the facility, irradiation of pure element or sample compound standards were performed to identify the gama-ray energies from each element and their count rates.

  10. First detection and characterization of Salmonella spp. in poultry and swine raised in backyard production systems in central Chile.

    PubMed

    Alegria-Moran, R; Rivera, D; Toledo, V; Moreno-Switt, A I; Hamilton-West, C

    2017-11-01

    Little is known about Salmonella serovars circulating in backyard poultry and swine populations worldwide. Backyard production systems (BPS) that raise swine and/or poultry are distributed across Chile, but are more heavily concentrated in central Chile, where industrialized systems are in close contact with BPS. This study aims to detect and identify circulating Salmonella serovars in poultry and swine raised in BPS. Bacteriological Salmonella isolation was carried out for 1744 samples collected from 329 BPS in central Chile. Faecal samples were taken from swine, poultry, geese, ducks, turkeys and peacocks, as well as environmental faecal samples. Confirmation of Salmonella spp. was performed using invA-polymerase chain reaction (PCR). Identification of serovars was carried out using a molecular serotyping approach, where serogroups were confirmed by a multiplex PCR of Salmonella serogroup genes for five Salmonella O antigens (i.e., D, B, C1, C2-C3, and E1), along with two PCR amplifications, followed by sequencing of fliC and fljB genes. A total of 25 samples (1·4% of total samples) from 15 BPS (4·6 % of total sampled BPS) were found positive for Salmonella. Positive samples were found in poultry (chickens and ducks), swine and environmental sources. Molecular prediction of serovars on Salmonella isolated showed 52·0% of S. Typhimurium, 16·0% of S. Infantis, 16·0% S. Enteritidis, 8·0% S. Hadar, 4·0% S. Tennessee and 4·0% S. Kentucky. Poor biosecurity measures were found on sampled BPS, where a high percentage of mixed confinement systems (72·8%); and almost half of the sampled BPS with improper management of infected mortalities (e.g. selling the carcasses of infected animals for consumption). Number of birds other than chickens (P = 0·014; OR = 1·04; IC (95%) = 1·01-1·07), mixed productive objective (P = 0·030; OR = 5·35; IC (95%) = 1·24-27·59) and mixed animal replacement origin (P = 0017; OR = 5·19; IC (95%) = 1·35-20·47) were detected as risk factors for BPS positivity to Salmonella spp. This is the first evidence of serovars of Salmonella spp. circulating in BPS from central Chile. Detected serovars have been linked to human and animal clinical outbreaks worldwide and in Chile, highlighting the importance of BPS on the control and dissemination of Salmonella serovars potentially hazardous to public health.

  11. Towards a Decentralized Magnetic Indoor Positioning System

    PubMed Central

    Kasmi, Zakaria; Norrdine, Abdelmoumen; Blankenbach, Jörg

    2015-01-01

    Decentralized magnetic indoor localization is a sophisticated method for processing sampled magnetic data directly on a mobile station (MS), thereby decreasing or even avoiding the need for communication with the base station. In contrast to central-oriented positioning systems, which transmit raw data to a base station, decentralized indoor localization pushes application-level knowledge into the MS. A decentralized position solution has thus a strong feasibility to increase energy efficiency and to prolong the lifetime of the MS. In this article, we present a complete architecture and an implementation for a decentralized positioning system. Furthermore, we introduce a technique for the synchronization of the observed magnetic field on the MS with the artificially-generated magnetic field from the coils. Based on real-time clocks (RTCs) and a preemptive operating system, this method allows a stand-alone control of the coils and a proper assignment of the measured magnetic fields on the MS. A stand-alone control and synchronization of the coils and the MS have an exceptional potential to implement a positioning system without the need for wired or wireless communication and enable a deployment of applications for rescue scenarios, like localization of miners or firefighters. PMID:26690145

  12. Towards a Decentralized Magnetic Indoor Positioning System.

    PubMed

    Kasmi, Zakaria; Norrdine, Abdelmoumen; Blankenbach, Jörg

    2015-12-04

    Decentralized magnetic indoor localization is a sophisticated method for processing sampled magnetic data directly on a mobile station (MS), thereby decreasing or even avoiding the need for communication with the base station. In contrast to central-oriented positioning systems, which transmit raw data to a base station, decentralized indoor localization pushes application-level knowledge into the MS. A decentralized position solution has thus a strong feasibility to increase energy efficiency and to prolong the lifetime of the MS. In this article, we present a complete architecture and an implementation for a decentralized positioning system. Furthermore, we introduce a technique for the synchronization of the observed magnetic field on the MS with the artificially-generated magnetic field from the coils. Based on real-time clocks (RTCs) and a preemptive operating system, this method allows a stand-alone control of the coils and a proper assignment of the measured magnetic fields on the MS. A stand-alone control and synchronization of the coils and the MS have an exceptional potential to implement a positioning system without the need for wired or wireless communication and enable a deployment of applications for rescue scenarios, like localization of miners or firefighters.

  13. Similar chemokine receptor profiles in lymphomas with central nervous system involvement - possible biomarkers for patient selection for central nervous system prophylaxis, a retrospective study.

    PubMed

    Lemma, Siria A; Pasanen, Anna Kaisa; Haapasaari, Kirsi-Maria; Sippola, Antti; Sormunen, Raija; Soini, Ylermi; Jantunen, Esa; Koivunen, Petri; Salokorpi, Niina; Bloigu, Risto; Turpeenniemi-Hujanen, Taina; Kuittinen, Outi

    2016-05-01

    Central nervous system (CNS) relapse occurs in around 5% of diffuse large B-cell lymphoma (DLBCL) cases. No biomarkers to identify high-risk patients have been discovered. We evaluated the expression of lymphocyte-guiding chemokine receptors in systemic and CNS lymphomas. Immunohistochemical staining for CXCR4, CXCR5, CCR7, CXCL12, and CXCL13 was performed on 89 tissue samples, including cases of primary central nervous system lymphoma (PCNSL), secondary CNS lymphoma (sCNSL), and systemic DLBCL. Also, 10 reactive lymph node samples were included. Immunoelectron microscopy was performed on two PCNSLs, one sCNSL, one systemic DLBCL, and one reactive lymph node samples, and staining was performed for CXCR4, CXCR5, CXCL12, and CXCL13. Chi-square test was used to determine correlations between clinical parameters, diagnostic groups, and chemokine receptor expression. Strong nuclear CXCR4 positivity correlated with systemic DLBCL, whereas strong cytoplasmic CXCR5 positivity correlated with CNS involvement (P = 0.003 and P = 0.039). Immunoelectron microscopy revealed a nuclear CXCR4 staining in reactive lymph node, compared with cytoplasmic and membranous localization seen in CNS lymphomas. We found that CNS lymphoma presented a chemokine receptor profile different from systemic disease. Our findings give new information on the CNS tropism of DLBCL and, if confirmed, may contribute to more effective targeting of CNS prophylaxis among patients with DLBCL. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Family-of-Origin Factors and Partner Violence in the Intimate Relationships of Gay Men Who Are HIV Positive

    ERIC Educational Resources Information Center

    Craft, Shonda M.; Serovich, Julianne M.

    2005-01-01

    This exploratory study examined the prevalence of intimate partner violence in a sample of gay men who are HIV positive. The concept of intergenerational transmission of violence, from family systems theory, provided the basis of this examination. It was hypothesized that men who had witnessed or experienced violence in their families of origin…

  15. Specific detection of cultivable Helicobacter pylori cells from wastewater treatment plants.

    PubMed

    Moreno, Yolanda; Ferrús, M Antonía

    2012-10-01

    Helicobacter pylori is present in surface water and wastewater, and biofilms in drinking water systems have been reported as possible reservoirs of H. pylori. However, its ability to survive in an infectious state in the environment is hindered because it rapidly loses its cultivability. The aim of this study was to determine the presence of cultivable and therefore viable H. pylori in wastewater treatment plants to understand the role of wastewater in the pathogen's transmission. A modified filter technique was used to obtain a positive H. pylori culture, and specific detection of this pathogen was achieved with FISH and PCR techniques. A total of six positive H. pylori cultures were obtained from the water samples, and molecular techniques positively identified H. pylori in 21 culture-negative samples. The combination of a culturing procedure after sample filtration followed by the application of a molecular method, such as PCR or FISH, provides a specific tool for the detection, identification, and direct visualization of cultivable and therefore viable H. pylori cells from complex mixed communities such as water samples. © 2012 Blackwell Publishing Ltd.

  16. A tree-like Bayesian structure learning algorithm for small-sample datasets from complex biological model systems.

    PubMed

    Yin, Weiwei; Garimalla, Swetha; Moreno, Alberto; Galinski, Mary R; Styczynski, Mark P

    2015-08-28

    There are increasing efforts to bring high-throughput systems biology techniques to bear on complex animal model systems, often with a goal of learning about underlying regulatory network structures (e.g., gene regulatory networks). However, complex animal model systems typically have significant limitations on cohort sizes, number of samples, and the ability to perform follow-up and validation experiments. These constraints are particularly problematic for many current network learning approaches, which require large numbers of samples and may predict many more regulatory relationships than actually exist. Here, we test the idea that by leveraging the accuracy and efficiency of classifiers, we can construct high-quality networks that capture important interactions between variables in datasets with few samples. We start from a previously-developed tree-like Bayesian classifier and generalize its network learning approach to allow for arbitrary depth and complexity of tree-like networks. Using four diverse sample networks, we demonstrate that this approach performs consistently better at low sample sizes than the Sparse Candidate Algorithm, a representative approach for comparison because it is known to generate Bayesian networks with high positive predictive value. We develop and demonstrate a resampling-based approach to enable the identification of a viable root for the learned tree-like network, important for cases where the root of a network is not known a priori. We also develop and demonstrate an integrated resampling-based approach to the reduction of variable space for the learning of the network. Finally, we demonstrate the utility of this approach via the analysis of a transcriptional dataset of a malaria challenge in a non-human primate model system, Macaca mulatta, suggesting the potential to capture indicators of the earliest stages of cellular differentiation during leukopoiesis. We demonstrate that by starting from effective and efficient approaches for creating classifiers, we can identify interesting tree-like network structures with significant ability to capture the relationships in the training data. This approach represents a promising strategy for inferring networks with high positive predictive value under the constraint of small numbers of samples, meeting a need that will only continue to grow as more high-throughput studies are applied to complex model systems.

  17. Quantitative Real-Time Legionella PCR for Environmental Water Samples: Data Interpretation

    PubMed Central

    Joly, Philippe; Falconnet, Pierre-Alain; André, Janine; Weill, Nicole; Reyrolle, Monique; Vandenesch, François; Maurin, Max; Etienne, Jerome; Jarraud, Sophie

    2006-01-01

    Quantitative Legionella PCRs targeting the 16S rRNA gene (specific for the genus Legionella) and the mip gene (specific for the species Legionella pneumophila) were applied to a total of 223 hot water system samples (131 in one laboratory and 92 in another laboratory) and 37 cooling tower samples (all in the same laboratory). The PCR results were compared with those of conventional culture. 16S rRNA gene PCR results were nonquantifiable for 2.8% of cooling tower samples and up to 39.1% of hot water system samples, and this was highly predictive of Legionella CFU counts below 250/liter. PCR cutoff values for identifying hot water system samples containing >103 CFU/liter legionellae were determined separately in each laboratory. The cutoffs differed widely between the laboratories and had sensitivities from 87.7 to 92.9% and specificities from 77.3 to 96.5%. The best specificity was obtained with mip PCR. PCR cutoffs could not be determined for cooling tower samples, as the results were highly variable and often high for culture-negative samples. Thus, quantitative Legionella PCR appears to be applicable to samples from hot water systems, but the positivity cutoff has to be determined in each laboratory. PMID:16597985

  18. Detection of Candida species by nested PCR method in one-humped camels (Camelus dromedarius).

    PubMed

    Parin, Ugur; Erbas, Goksel; Kirkan, Sukru; Savasan, Serap; Tugba Yuksel, H; Balat, Gamze

    2018-02-01

    Systemic fungal diseases are the infections caused by false treatment protocols and generally are not taken into consideration especially in the veterinary field. One-humped camels are found in the western side of the Aegean region of our country and bred for wrestling. The aim of this study is the application of diagnosing systemic fungi infection from camel blood samples by the PCR method. In this study, specific primers for DNA topoisomerase II gene sequences were used. As a result, a systemic fungal infection was detected by the nested PCR method from 10 (20%) out of 50 DNA samples taken from camels located on the western side of the Aegean region. In this study, 3 (30%) samples were identified as Candida albicans, 3 (30%) samples were identified as C. glabrata, and 4 (40%) samples were identified as C. parapsilosis. In conclusion, the 20% positive systemic fungal infection rate in one-humped camels observed in the present study showed that the systemic fungal infections are not taken into considerations in veterinary medicine. Further studies are suggested in order to obtain and to maintain extensive data for systemic fungal diseases in our country for one-humped camels.

  19. Direct typing of Canine parvovirus (CPV) from infected dog faeces by rapid mini sequencing technique.

    PubMed

    V, Pavana Jyothi; S, Akila; Selvan, Malini K; Naidu, Hariprasad; Raghunathan, Shwethaa; Kota, Sathish; Sundaram, R C Raja; Rana, Samir Kumar; Raj, G Dhinakar; Srinivasan, V A; Mohana Subramanian, B

    2016-12-01

    Canine parvovirus (CPV) is a non-enveloped single stranded DNA virus with an icosahedral capsid. Mini-sequencing based CPV typing was developed earlier to detect and differentiate all the CPV types and FPV in a single reaction. This technique was further evaluated in the present study by performing the mini-sequencing directly from fecal samples which avoided tedious virus isolation steps by cell culture system. Fecal swab samples were collected from 84 dogs with enteritis symptoms, suggestive of parvoviral infection from different locations across India. Seventy six of these samples were positive by PCR; the subsequent mini-sequencing reaction typed 74 of them as type 2a virus, and 2 samples as type 2b. Additionally, 25 of the positive samples were typed by cycle sequencing of PCR products. Direct CPV typing from fecal samples using mini-sequencing showed 100% correlation with CPV typing by cycle sequencing. Moreover, CPV typing was achieved by mini-sequencing even with faintly positive PCR amplicons which was not possible by cycle sequencing. Therefore, the mini-sequencing technique is recommended for regular epidemiological follow up of CPV types, since the technique is rapid, highly sensitive and high capacity method for CPV typing. Copyright © 2016. Published by Elsevier B.V.

  20. [Helminth prevalence in a waste-water plant at El Rosal, Cundinamarca].

    PubMed

    Ortiz, Carolina; López, Myriam C; Rivas, Favio A

    2012-01-01

    Assessing helminth egg prevalence in sludge and raw and treated wastewater from a wastewater treatment system located in the village of El Rosal, Cundinamarca. 30 wastewater and 10 sludge samples from the El Rosal plant were taken during a 10-week period. The sludge and water samples were processed according to the Bailinger and the official Mexican standard methodology, respectively. Egg viability was determined by the method described by Victórica & Galván and the Mexican official standard. Descriptive statistics were used for analysing data. 100 % of the untreated wastewater samples showed the presence of eggs and at least one viable helminth egg/litre was found in 90 % of them. 90 % of the treated wastewater samples were positive for the presence of eggs, finding that 70 % had at least one viable egg. All raw wastewater samples being dumped directly into the stream were positive for helminths; the same situation was found at the time of the viability test. All sludge samples were positive for helminths, finding that 100 % of these had at least one viable egg. Using this water for crop irrigation and using the sludge as fertiliser is a potential risk for public health. The sludge can only be used in forestry activities, as long as it does not come into contact with humans.

  1. Evaluation of a microbiological indicator test for antibiotic detection in ewe and goat milk.

    PubMed

    Comunian, R; Paba, A; Dupré, I; Daga, E S; Scintu, M F

    2010-12-01

    Antibiotics are widely used for therapeutic and prophylactic purposes in dairy animals. The presence of residual antibiotics in milk could cause potentially serious problems in human health and have technological implication in the manufacturing of dairy products. The aim of this study was to evaluate Delvotest Accelerator (DSM Food Specialties, Delft, the Netherlands), a new system for a fully automated microbial test to detect antibiotic residues in ewe and goat milk. Forty-three samples of raw, whole, refrigerated bulk-tank milk samples (22 of ewe milk and 21 of goat milk) were analyzed during the whole lactation period. Four concentrations of 4 antibiotics were diluted in milk: penicillin G at 1, 2, 3, and 4 μg/L; sulfadiazine at 25, 50, 100, and 200 μg/L; tetracycline at 50, 100, 200, and 400 μg/L; and gentamicin at 25, 50, 100, and 200 μg/L. The detection limit of the Delvotest Accelerator was calculated as the range of antibiotic concentrations within which 95% of positive result lie. The range of detection limit of penicillin G and sulfadiazine was easily detected by Delvotest Accelerator at or below the European Union maximum residue limits, both for ewe and goat milk samples. In contrast, the system showed a lower ability to detect tetracycline and gentamicin both for ewe and goat milk samples. Very low percentages of false-positive outcomes were obtained. Lactation phase did not seem to be a crucial factor affecting the ability of the Delvotest Accelerator to detect spiked milk samples. A higher detection ability was observed for goat milk samples compared with ewe milk samples. A negative correlation between the percentage of positive milk samples detected and milk fat, protein, and lactose contents was observed for gentamicin only. Copyright © 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  2. Screening portal, system and method of using same

    DOEpatents

    Linker, Kevin L.; Hunter, John A.; Brusseau, Charles A.

    2013-04-30

    A portal, system and method for screening an object for a target substance is provided. The portal includes an inflatable bladder expandable to form a test space for receiving the object and a plurality of nozzles positioned about the inflatable bladder. The nozzles are in fluid communication with a fluid source for directing air over the object whereby samples are removed from the object for examination. A collector is operatively connected to the inflatable bladder for collecting the samples removed from the object. A detector is operatively connected to the collector for examining the removed samples for the presence of the target substance. At least one preconcentrator may be operatively connected to the collector for concentrating the samples collected thereby.

  3. Microfluidic on-chip fluorescence-activated interface control system

    PubMed Central

    Haiwang, Li; Nguyen, N. T.; Wong, T. N.; Ng, S. L.

    2010-01-01

    A microfluidic dynamic fluorescence-activated interface control system was developed for lab-on-a-chip applications. The system consists of a straight rectangular microchannel, a fluorescence excitation source, a detection sensor, a signal conversion circuit, and a high-voltage feedback system. Aqueous NaCl as conducting fluid and aqueous glycerol as nonconducting fluid were introduced to flow side by side into the straight rectangular microchannel. Fluorescent dye was added to the aqueous NaCl to work as a signal representing the interface position. Automatic control of the liquid interface was achieved by controlling the electroosmotic effect that exists only in the conducting fluid using a high-voltage feedback system. A LABVIEW program was developed to control the output of high-voltage power supply according the actual interface position, and then the interface position is modified as the output of high-voltage power supply. At last, the interface can be moved to the desired position automatically using this feedback system. The results show that the system presented in this paper can control an arbitrary interface location in real time. The effects of viscosity ratio, flow rates, and polarity of electric field were discussed. This technique can be extended to switch the sample flow and droplets automatically. PMID:21173886

  4. Purge water management system

    DOEpatents

    Cardoso-Neto, J.E.; Williams, D.W.

    1995-01-01

    A purge water management system is described for effectively eliminating the production of purge water when obtaining a groundwater sample from a monitoring well. In its preferred embodiment, the purge water management system comprises an expandable container, a transportation system, and a return system. The purge water management system is connected to a wellhead sampling configuration, typically permanently installed at the well site. A pump, positioned with the monitoring well, pumps groundwater through the transportation system into the expandable container, which expands in direct proportion with volume of groundwater introduced, usually three or four well volumes, yet prevents the groundwater from coming into contact with the oxygen in the air. After this quantity of groundwater has been removed from the well, a sample is taken from a sampling port, after which the groundwater in the expandable container can be returned to the monitoring well through the return system. The purge water management system prevents the purge water from coming in contact with the outside environment, especially oxygen, which might cause the constituents of the groundwater to oxidize. Therefore, by introducing the purge water back into the monitoring well, the necessity of dealing with the purge water as a hazardous waste under the Resource Conservation and Recovery Act is eliminated.

  5. Purge water management system

    DOEpatents

    Cardoso-Neto, Joao E.; Williams, Daniel W.

    1996-01-01

    A purge water management system for effectively eliminating the production of purge water when obtaining a groundwater sample from a monitoring well. In its preferred embodiment, the purge water management system comprises an expandable container, a transportation system, and a return system. The purge water management system is connected to a wellhead sampling configuration, typically permanently installed at the well site. A pump, positioned with the monitoring well, pumps groundwater through the transportation system into the expandable container, which expands in direct proportion with volume of groundwater introduced, usually three or four well volumes, yet prevents the groundwater from coming into contact with the oxygen in the air. After this quantity of groundwater has been removed from the well, a sample is taken from a sampling port, after which the groundwater in the expandable container can be returned to the monitoring well through the return system. The purge water management system prevents the purge water from coming in contact with the outside environment, especially oxygen, which might cause the constituents of the groundwater to oxidize. Therefore, by introducing the purge water back into the monitoring well, the necessity of dealing with the purge water as a hazardous waste under the Resource Conservation and Recovery Act is eliminated.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nozaki, T., E-mail: nozaki@ecei.tohoku.ac.jp; Oida, M.; Ashida, T.

    We investigated the effect of Pt insertion on a Cr{sub 2}O{sub 3}/Co exchange coupling system. The perpendicular exchange bias μ{sub 0}H{sub ex} decreased with increasing Pt insertion layer thickness, and we observed positive μ{sub 0}H{sub ex} for samples with relatively thick Pt insertion layers. We also examined the cooling field μ{sub 0}H{sub fc} dependence of μ{sub 0}H{sub ex} for the samples. At small μ{sub 0}H{sub fc}, all samples exhibited negative μ{sub 0}H{sub ex}. With increasing μ{sub 0}H{sub fc}, a shift of μ{sub 0}H{sub ex} from negative to positive was observed. In the past, similar behaviors were observed for FeF{sub 2}/Femore » systems exhibiting positive μ{sub 0}H{sub ex}. In addition, the μ{sub 0}H{sub fc} dependence of μ{sub 0}H{sub ex} was well fitted by an equation taking into account the Zeeman energy at the surface of an antiferromagnet as well as an antiferromagnetic exchange coupling. The results strongly suggest that (1) Cr{sub 2}O{sub 3} surface spin is affected by the external magnetic field and (2) the coupling at the Cr{sub 2}O{sub 3}/Pt/Co interface is antiferromagnetic.« less

  7. Free-living amoebae and their associated bacteria in Austrian cooling towers: a 1-year routine screening.

    PubMed

    Scheikl, Ute; Tsao, Han-Fei; Horn, Matthias; Indra, Alexander; Walochnik, Julia

    2016-09-01

    Free-living amoebae (FLA) are widely spread in the environment and known to cause rare but often serious infections. Besides this, FLA may serve as vehicles for bacterial pathogens. In particular, Legionella pneumophila is known to replicate within FLA thereby also gaining enhanced infectivity. Cooling towers have been the source of outbreaks of Legionnaires' disease in the past and are thus usually screened for legionellae on a routine basis, not considering, however, FLA and their vehicle function. The aim of this study was to incorporate a screening system for host amoebae into a Legionella routine screening. A new real-time PCR-based screening system for various groups of FLA was established. Three cooling towers were screened every 2 weeks over the period of 1 year for FLA and Legionella spp., by culture and molecular methods in parallel. Altogether, 83.3 % of the cooling tower samples were positive for FLA, Acanthamoeba being the dominating genus. Interestingly, 69.7 % of the cooling tower samples were not suitable for the standard Legionella screening due to their high organic burden. In the remaining samples, positivity for Legionella spp. was 25 % by culture, but overall positivity was 50 % by molecular methods. Several amoebal isolates revealed intracellular bacteria.

  8. Real-time polymerase chain reaction detection of cauliflower mosaic virus to complement the 35S screening assay for genetically modified organisms.

    PubMed

    Cankar, Katarina; Ravnikar, Maja; Zel, Jana; Gruden, Kristina; Toplak, Natasa

    2005-01-01

    Labeling of genetically modified organisms (GMOs) is now in place in many countries, including the European Union, in order to guarantee the consumer's choice between GM and non-GM products. Screening of samples is performed by polymerase chain reaction (PCR) amplification of regulatory sequences frequently introduced into genetically modified plants. Primers for the 35S promoter from Cauliflower mosaic virus (CaMV) are those most frequently used. In virus-infected plants or in samples contaminated with plant material carrying the virus, false-positive results can consequently occur. A system for real-time PCR using a TaqMan minor groove binder probe was designed that allows recognition of virus coat protein in the sample, thus allowing differentiation between transgenic and virus-infected samples. We measured the efficiency of PCR amplification, limits of detection and quantification, range of linearity, and repeatability of the assay in order to assess the applicability of the assay for routine analysis. The specificity of the detection system was tested on various virus isolates and plant species. All 8 CaMV isolates were successfully amplified using the designed system. No cross-reactivity was detected with DNA from 3 isolates of the closely related Carnation etched ring virus. Primers do not amplify plant DNA from available genetically modified maize and soybean lines or from different species of Brassicaceae or Solanaceae that are natural hosts for CaMV. We evaluated the assay for different food matrixes by spiking CaMV DNA into DNA from food samples and have successfully amplified CaMV from all samples. The assay was tested on rapeseed samples from routine GMO testing that were positive in the 35S screening assay, and the presence of the virus was confirmed.

  9. Longitudinal study of Escherichia coli O157 shedding and super shedding in dairy heifers.

    PubMed

    Williams, K J; Ward, M P; Dhungyel, O P

    2015-04-01

    A longitudinal study was conducted to assess the methods available for detection of Escherichia coli O157 and to investigate the prevalence and occurrence of long-term shedding and super shedding in a cohort of Australian dairy heifers. Samples were obtained at approximately weekly intervals from heifers at pasture under normal management systems. Selective sampling techniques were used with the aim of identifying heifers with a higher probability of shedding or super shedding. Rectoanal mucosal swabs (RAMS) and fecal samples were obtained from each heifer. Direct culture of feces was used for detection and enumeration. Feces and RAMS were tested by enrichment culture. Selected samples were further tested retrospectively by immunomagnetic separation of enriched samples. Of 784 samples obtained, 154 (19.6%) were detected as positive using culture methods. Adjusting for selective sampling, the prevalence was 71 (15.6%) of 454. In total, 66 samples were detected as positive at >10(2) CFU/g of which 8 were >10(4) CFU/g and classed as super shedding. A significant difference was observed in detection by enriched culture of RAMS and feces. Dairy heifers within this cohort exhibited variable E. coli O157 shedding, consistent with previous estimates of shedding. Super shedding was detected at a low frequency and inconsistently from individual heifers. All detection methods identified some samples as positive that were not detected by any other method, indicating that the testing methods used will influence survey results.

  10. Automated image processing method for the diagnosis and classification of malaria on thin blood smears.

    PubMed

    Ross, Nicholas E; Pritchard, Charles J; Rubin, David M; Dusé, Adriano G

    2006-05-01

    Malaria is a serious global health problem, and rapid, accurate diagnosis is required to control the disease. An image processing algorithm to automate the diagnosis of malaria on thin blood smears is developed. The image classification system is designed to positively identify malaria parasites present in thin blood smears, and differentiate the species of malaria. Images are acquired using a charge-coupled device camera connected to a light microscope. Morphological and novel threshold selection techniques are used to identify erythrocytes (red blood cells) and possible parasites present on microscopic slides. Image features based on colour, texture and the geometry of the cells and parasites are generated, as well as features that make use of a priori knowledge of the classification problem and mimic features used by human technicians. A two-stage tree classifier using backpropogation feedforward neural networks distinguishes between true and false positives, and then diagnoses the species (Plasmodium falciparum, P. vivax, P. ovale or P. malariae) of the infection. Malaria samples obtained from the Department of Clinical Microbiology and Infectious Diseases at the University of the Witwatersrand Medical School are used for training and testing of the system. Infected erythrocytes are positively identified with a sensitivity of 85% and a positive predictive value (PPV) of 81%, which makes the method highly sensitive at diagnosing a complete sample provided many views are analysed. Species were correctly determined for 11 out of 15 samples.

  11. Comparison of beam position calculation methods for application in digital acquisition systems

    NASA Astrophysics Data System (ADS)

    Reiter, A.; Singh, R.

    2018-05-01

    Different approaches to the data analysis of beam position monitors in hadron accelerators are compared adopting the perspective of an analog-to-digital converter in a sampling acquisition system. Special emphasis is given to position uncertainty and robustness against bias and interference that may be encountered in an accelerator environment. In a time-domain analysis of data in the presence of statistical noise, the position calculation based on the difference-over-sum method with algorithms like signal integral or power can be interpreted as a least-squares analysis of a corresponding fit function. This link to the least-squares method is exploited in the evaluation of analysis properties and in the calculation of position uncertainty. In an analytical model and experimental evaluations the positions derived from a straight line fit or equivalently the standard deviation are found to be the most robust and to offer the least variance. The measured position uncertainty is consistent with the model prediction in our experiment, and the results of tune measurements improve significantly.

  12. Positive Attitude Toward Math Supports Early Academic Success: Behavioral Evidence and Neurocognitive Mechanisms.

    PubMed

    Chen, Lang; Bae, Se Ri; Battista, Christian; Qin, Shaozheng; Chen, Tianwen; Evans, Tanya M; Menon, Vinod

    2018-03-01

    Positive attitude is thought to impact academic achievement and learning in children, but little is known about its underlying neurocognitive mechanisms. Using a large behavioral sample of 240 children, we found that positive attitude toward math uniquely predicted math achievement, even after we accounted for multiple other cognitive-affective factors. We then investigated the neural mechanisms underlying the link between positive attitude and academic achievement in two independent cohorts of children (discovery cohort: n = 47; replication cohort: n = 28) and tested competing hypotheses regarding the differential roles of affective-motivational and learning-memory systems. In both cohorts, we found that positive attitude was associated with increased engagement of the hippocampal learning-memory system. Structural equation modeling further revealed that, in both cohorts, increased hippocampal activity and more frequent use of efficient memory-based strategies mediated the relation between positive attitude and higher math achievement. Our study is the first to elucidate the neurocognitive mechanisms by which positive attitude influences learning and academic achievement.

  13. A large seroprevalence survey of brucellosis in cattle herds under diverse production systems in northern Nigeria

    PubMed Central

    2012-01-01

    Background This study was carried out to investigate the status of brucellosis in cattle under various management systems in Adamawa, Kaduna and Kano states, northern Nigeria. Using multi-stage sampling, serum samples of 4,745 cattle from 271 herds were tested using the Rose-Bengal plate-agglutination test (RBPT) and positives were confirmed using a competitive enzyme-linked immunosorbent assay (c-ELISA). Results Prevalence estimates were calculated by adjusting for sampling weights and where possible for test sensitivity and specificity. Thirty-seven percent of all animals were RBPT positive, and after confirmation with c-ELISA the overall animal-level prevalence, adjusted for sampling weights, was 26.3% (95% CI, 22.1%-31.0%). Of the herds sampled, 210 (77.5%; 95% CI, 68.6%-84.5%) had at least one animal positive to both tests; this did not differ significantly between states (P = 0.538). Mean within-herd seroprevalence in positive herds was 30.2% (95% CI, 25.3%-35.1%) and ranged from 3.1% to 85.7%. Overall animal-level seroprevalences of 29.2% (95% CI, 22.5%-36.9%) n = 1,827, 23.3% (95% CI, 18.9%-28.3%) n = 1,870 and 26.7% (95% CI, 18.8%-36.7%) n = 1,048 were observed in Adamawa, Kaduna and Kano states, respectively (P = 0.496). A significantly higher seroprevalence was found in males (38.2%; 95% CI, 31.7%-45.2%) than in females (24.7%; 95% CI, 20.4%-29.5%) (P < 0.001) and in non-pregnant females (27.8%; 95% CI, 22.9%-33.5%) than in pregnant females (17.2%; 95% CI, 13.6%-21.5%) (P < 0.001). Seroprevalence increased with increasing age (P < 0.001), from 13.5% (95% CI, 8.9%-19.9%) in cattle <4 years to 35.0% (95% CI, 28.5%-42.3%) in cattle >7 years. Seroprevalence also varied between management systems (P < 0.001): pastoral systems 45.1% (95% CI, 38.6%-51.9%), zero-grazing systems 23.8% (95% CI, 6.8%-59.2%), agro-pastoral systems 22.0% (95% CI, 17.3%-27.8%), and commercial farms 15.9% (95% CI, 9.5%-25.5%). Seroprevalence did not differ significantly between breeds or lactation status. Conclusion This is the first large study to assess the prevalence of bovine brucellosis over a wide geographic area of northern Nigeria, in a variety of management systems and using accurate tests. The seroprevalence of brucellosis was high, and higher than results of previous studies in northern Nigeria. The pastoral management systems of the traditional Fulanis may be encouraging the dissemination of the disease. Public enlightenment of the farmers about the disease, vaccination and appropriate national control measures are recommended. PMID:22920578

  14. Design and demonstration of an advanced data collection/position location system

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The final report on a breadboard evaluation and demonstration program is reported concerning the applicability of MSK modulation and chirp-z transformer technology in Advanced Data Collection/Position Location (ADC/PL) systems. The program effort consisted of three phases - design, testing, and evaluation. Section 2 describes the breadboard hardware built during the design phase of the program, Section 3 describes the tests conducted on the breadboard and the results of the tests, and Section 4 presents a brief analysis and summary of the findings of the breadboard tests and develops a sample ADC/PL system which incorporates both MSK modulation and a chirp-z transformer.

  15. Enteric protozoa of cats and their zoonotic potential-a field study from Austria.

    PubMed

    Hinney, Barbara; Ederer, Christina; Stengl, Carina; Wilding, Katrin; Štrkolcová, Gabriela; Harl, Josef; Flechl, Eva; Fuehrer, Hans-Peter; Joachim, Anja

    2015-05-01

    Domestic cats can be infected with a variety of enteric protozoa. Genotyping of protozoan species, especially Giardia as the most common, can improve assessment of their relevance as zoonotic agents. For an overview on the occurrence of feline enteric protozoa, 298 faecal samples of cats from private households, catteries and animal shelters in Austria were collected. All samples were examined by flotation and using a rapid test for Giardia (FASTest). For the detection of Tritrichomonas blagburni, freshly voided faeces (n = 40) were processed using a commercial culturing system (InPouch TF-Feline). Genotyping was done at the β-giardin gene loci (each sample) and triosephosphate isomerase gene loci (positive samples) for Giardia and at the 18S rRNA gene (positive samples) for Cryptosporidium. Thirty-seven samples (12.4%) were positive for Giardia by flotation and/or using a rapid test. Cryptosporidium was present in 1.7%, Cystoisospora in 4.0%, Sarcocystis in 0.3% and T. blagburni in 2.5% of the samples. Genotyping revealed Giardia cati, the potentially zoonotic Giardia duodenalis and Cryptosporidium felis. Most of the infected cats had no diarrhoea. Cats from shelters were significantly more often infected than owned cats (p = 0.01). When comparing Giardia detection methods, the rapid test had a higher sensitivity than flotation. Polymerase chain reaction (PCR) results were mostly independent from the other two tests.

  16. Cross-instrument Analysis Correlation Software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McJunkin, Timothy R.

    This program has been designed to assist with the tracking of a sample from one analytical instrument to another such as SEM, microscopes, micro x-ray diffraction and other instruments where particular positions/locations on the sample are examined, photographed, etc. The software is designed to easily enter the position of fiducials and locations of interest such that in a future session in the same of different instrument the positions of interest can be re-found through using the known location fiducials in the current and reference session to transform the point into the current sessions coordinate system. The software is dialog boxmore » driven guiding the user through the necessary data entry and program choices. Information is stored in a series of text based extensible markup language (XML) files.« less

  17. 40 CFR 141.860 - Violations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PRIMARY DRINKING WATER REGULATIONS Revised Total Coliform Rule § 141.860 Violations. (a) E. coli MCL Violation. A system is in violation of the MCL for E. coli when any of the conditions identified in paragraphs (a)(1) through (a)(4) of this section occur. (1) The system has an E. coli-positive repeat sample...

  18. 40 CFR 141.860 - Violations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PRIMARY DRINKING WATER REGULATIONS Revised Total Coliform Rule § 141.860 Violations. (a) E. coli MCL Violation. A system is in violation of the MCL for E. coli when any of the conditions identified in paragraphs (a)(1) through (a)(4) of this section occur. (1) The system has an E. coli-positive repeat sample...

  19. Transformation of Personal Computers and Mobile Phones into Genetic Diagnostic Systems

    DTIC Science & Technology

    2014-08-31

    a Gel Logic System using UV transillumination and a 535 nm optical filter ( Kodak ). The positive control PCR was performed by taking an aliquot of the...described in the section above. Samples were excited by a UV transilluminator ( Kodak ). For imaging, a 520 ± 10 nm bandpass filter (Edmund Optics) was

  20. Oxidized Mn:Ge magnetic semiconductor: Observation of anomalous Hall effect and large magnetoresistance

    NASA Astrophysics Data System (ADS)

    Duc Dung, Dang; Choi, Jiyoun; Feng, Wuwei; Cao Khang, Nguyen; Cho, Sunglae

    2018-03-01

    We report on the structural and magneto-transport properties of the as-grown and oxidized Mn:Ge magnetic semiconductors. Based on X-ray diffraction and X-ray photoelectron spectroscopy results, the samples annealed at 650 and 700 °C became fully oxidized and the chemical binding energies of Mn was found to be Mn3O4. Thus, the system became Mn3O4 clusters embedded in Ge1-yOy. The as-grown sample showed positive linear Hall effect and negligible negative magnetoresistance (MR), which trend remained for the sample annealed up to 550 °C. Interestingly, for the samples annealed at above 650 °C, we observed the anomalous Hall effect around 45 K and the giant positive MR, which are respectively 59.2% and 78.5% at 7 kOe annealed at 650 °C and 700 °C.

  1. A comparison of temporal and location-based sampling strategies for global positioning system-triggered electronic diaries.

    PubMed

    Törnros, Tobias; Dorn, Helen; Reichert, Markus; Ebner-Priemer, Ulrich; Salize, Hans-Joachim; Tost, Heike; Meyer-Lindenberg, Andreas; Zipf, Alexander

    2016-11-21

    Self-reporting is a well-established approach within the medical and psychological sciences. In order to avoid recall bias, i.e. past events being remembered inaccurately, the reports can be filled out on a smartphone in real-time and in the natural environment. This is often referred to as ambulatory assessment and the reports are usually triggered at regular time intervals. With this sampling scheme, however, rare events (e.g. a visit to a park or recreation area) are likely to be missed. When addressing the correlation between mood and the environment, it may therefore be beneficial to include participant locations within the ambulatory assessment sampling scheme. Based on the geographical coordinates, the database query system then decides if a self-report should be triggered or not. We simulated four different ambulatory assessment sampling schemes based on movement data (coordinates by minute) from 143 voluntary participants tracked for seven consecutive days. Two location-based sampling schemes incorporating the environmental characteristics (land use and population density) at each participant's location were introduced and compared to a time-based sampling scheme triggering a report on the hour as well as to a sampling scheme incorporating physical activity. We show that location-based sampling schemes trigger a report less often, but we obtain more unique trigger positions and a greater spatial spread in comparison to sampling strategies based on time and distance. Additionally, the location-based methods trigger significantly more often at rarely visited types of land use and less often outside the study region where no underlying environmental data are available.

  2. Six years' experience of using the BacT/ALERT system to screen all platelet concentrates, and additional testing of outdated platelet concentrates to estimate the frequency of false-negative results.

    PubMed

    Larsen, C P; Ezligini, F; Hermansen, N O; Kjeldsen-Kragh, J

    2005-02-01

    Approximately 1 in every 2000 units of platelets is contaminated with bacteria. The BacT/ALERT automated blood culture system can be used to screen platelet concentrates (PCs) for bacterial contamination. Data were collected from May 1998 until May 2004. The number of PCs tested during this period was 36 896, most of which were produced from pools of four buffy-coats. On the day following blood collection or platelet apheresis, a 5-10 ml sample of the PC was aseptically transferred to a BacT/ALERT culture bottle for detection of aerobic bacteria. The sample was monitored for bacterial growth during the entire storage period of the PC (6.5 days). When a positive signal was generated, the culture bottle, the PC and the erythrocyte concentrates were tested for bacterial growth. In order to determine the frequency of false-negative BacT/ALERT signals, 1061 outdated PCs were tested during the period from May 2002 to May 2004. Eighty-eight positive signals were detected by the BacT/ALERT system, of which 12 were interpreted as truly positive. Fourteen signals were interpreted as truly false positive. Thirty-three signals were interpreted to be probably false positive. Two of 1061 outdated units tested positive, and Bacillus spp. and Staphylococcus epidermidis, respectively, were isolated from these PCs. Between 0.03% and 0.12% of the PCs were contaminated with bacteria. BacT/ALERT is an efficient tool for monitoring PCs for bacterial contamination; however, it is important to realize that false-negative results may occur.

  3. Rapid Detection of Mycobacterium tuberculosis and Rifampin Resistance by Use of On-Demand, Near-Patient Technology▿ † ‡

    PubMed Central

    Helb, Danica; Jones, Martin; Story, Elizabeth; Boehme, Catharina; Wallace, Ellen; Ho, Ken; Kop, JoAnn; Owens, Michelle R.; Rodgers, Richard; Banada, Padmapriya; Safi, Hassan; Blakemore, Robert; Lan, N. T. Ngoc; Jones-López, Edward C.; Levi, Michael; Burday, Michele; Ayakaka, Irene; Mugerwa, Roy D.; McMillan, Bill; Winn-Deen, Emily; Christel, Lee; Dailey, Peter; Perkins, Mark D.; Persing, David H.; Alland, David

    2010-01-01

    Current nucleic acid amplification methods to detect Mycobacterium tuberculosis are complex, labor-intensive, and technically challenging. We developed and performed the first analysis of the Cepheid Gene Xpert System's MTB/RIF assay, an integrated hands-free sputum-processing and real-time PCR system with rapid on-demand, near-patient technology, to simultaneously detect M. tuberculosis and rifampin resistance. Analytic tests of M. tuberculosis DNA demonstrated a limit of detection (LOD) of 4.5 genomes per reaction. Studies using sputum spiked with known numbers of M. tuberculosis CFU predicted a clinical LOD of 131 CFU/ml. Killing studies showed that the assay's buffer decreased M. tuberculosis viability by at least 8 logs, substantially reducing biohazards. Tests of 23 different commonly occurring rifampin resistance mutations demonstrated that all 23 (100%) would be identified as rifampin resistant. An analysis of 20 nontuberculosis mycobacteria species confirmed high assay specificity. A small clinical validation study of 107 clinical sputum samples from suspected tuberculosis cases in Vietnam detected 29/29 (100%) smear-positive culture-positive cases and 33/39 (84.6%) or 38/53 (71.7%) smear-negative culture-positive cases, as determined by growth on solid medium or on both solid and liquid media, respectively. M. tuberculosis was not detected in 25/25 (100%) of the culture-negative samples. A study of 64 smear-positive culture-positive sputa from retreatment tuberculosis cases in Uganda detected 63/64 (98.4%) culture-positive cases and 9/9 (100%) cases of rifampin resistance. Rifampin resistance was excluded in 54/55 (98.2%) susceptible cases. Specificity rose to 100% after correcting for a conventional susceptibility test error. In conclusion, this highly sensitive and simple-to-use system can detect M. tuberculosis directly from sputum in less than 2 h. PMID:19864480

  4. Ostertagia ostertagi antibodies in milk samples: relationships with herd management and milk production parameters in two Mediterranean production systems of Spain.

    PubMed

    Almería, S; Adelantado, C; Charlier, J; Claerebout, E; Bach, A

    2009-12-01

    The present study analyzed Ostertagia ostertagi antibodies by indirect ELISA in milk samples in two cattle systems in Mediterranean Spain to indirectly monitor gastrointestinal nematode (GI) parasitism effects on production. Individual samples from 10 animals and the corresponding milk herd samples were collected from 133 herds in Girona (intensive management) and 123 herds in Minorca (extensive management). Both locations showed high and significant positive relationships between average optical density ratios (ODR) of individual animals and ODR in their milk tank. Although antibodies levels were low, there were significantly higher in Minorca. Negative correlations between ODR values and milk production were found in both systems. Importantly, in Minorca, average herd milk production was higher in the herds that treated their animals against GI nematodes compared to those that did not treat. The ELISA technique was valuable to indirectly assess differences in the level of GI nematode infection even in cattle production systems with low levels of infection.

  5. Multiple-scanning-probe tunneling microscope with nanoscale positional recognition function.

    PubMed

    Higuchi, Seiji; Kuramochi, Hiromi; Laurent, Olivier; Komatsubara, Takashi; Machida, Shinichi; Aono, Masakazu; Obori, Kenichi; Nakayama, Tomonobu

    2010-07-01

    Over the past decade, multiple-scanning-probe microscope systems with independently controlled probes have been developed for nanoscale electrical measurements. We developed a quadruple-scanning-probe tunneling microscope (QSPTM) that can determine and control the probe position through scanning-probe imaging. The difficulty of operating multiple probes with submicrometer precision drastically increases with the number of probes. To solve problems such as determining the relative positions of the probes and avoiding of contact between the probes, we adopted sample-scanning methods to obtain four images simultaneously and developed an original control system for QSPTM operation with a function of automatic positional recognition. These improvements make the QSPTM a more practical and useful instrument since four images can now be reliably produced, and consequently the positioning of the four probes becomes easier owing to the reduced chance of accidental contact between the probes.

  6. Epidemiology of influenza in West Africa after the 2009 influenza A(H1N1) pandemic, 2010-2012.

    PubMed

    Talla Nzussouo, Ndahwouh; Duque, Jazmin; Adedeji, Adebayo Abel; Coulibaly, Daouda; Sow, Samba; Tarnagda, Zekiba; Maman, Issaka; Lagare, Adamou; Makaya, Sonia; Elkory, Mohamed Brahim; Kadjo Adje, Herve; Shilo, Paul Alhassan; Tamboura, Boubou; Cisse, Assana; Badziklou, Kossi; Maïnassara, Halima Boubacar; Bara, Ahmed Ould; Keita, Adama Mamby; Williams, Thelma; Moen, Ann; Widdowson, Marc-Alain; McMorrow, Meredith

    2017-12-04

    Over the last decade, capacity for influenza surveillance and research in West Africa has strengthened. Data from these surveillance systems showed influenza A(H1N1)pdm09 circulated in West Africa later than in other regions of the continent. We contacted 11 West African countries to collect information about their influenza surveillance systems (number of sites, type of surveillance, sampling strategy, populations sampled, case definitions used, number of specimens collected and number of specimens positive for influenza viruses) for the time period January 2010 through December 2012. Of the 11 countries contacted, 8 responded: Burkina Faso, Cote d'Ivoire, Mali, Mauritania, Niger, Nigeria, Sierra Leone and Togo. Countries used standard World Health Organization (WHO) case definitions for influenza-like illness (ILI) and severe acute respiratory illness (SARI) or slight variations thereof. There were 70 surveillance sites: 26 SARI and 44 ILI. Seven countries conducted SARI surveillance and collected 3114 specimens of which 209 (7%) were positive for influenza viruses. Among influenza-positive SARI patients, 132 (63%) were influenza A [68 influenza A(H1N1)pdm09, 64 influenza A(H3N2)] and 77 (37%) were influenza B. All eight countries conducted ILI surveillance and collected 20,375 specimens, of which 2278 (11%) were positive for influenza viruses. Among influenza-positive ILI patients, 1431 (63%) were influenza A [820 influenza A(H1N1)pdm09, 611 influenza A(H3N2)] and 847 (37%) were influenza B. A majority of SARI and ILI case-patients who tested positive for influenza (72% SARI and 59% ILI) were children aged 0-4 years, as were a majority of those enrolled in surveillance. The seasonality of influenza and the predominant influenza type or subtype varied by country and year. Influenza A(H1N1)pdm09 continued to circulate in West Africa along with influenza A(H3N2) and influenza B during 2010-2012. Although ILI surveillance systems produced a robust number of samples during the study period, more could be done to strengthen surveillance among hospitalized SARI case-patients. Surveillance systems captured young children but lacked data on adults and the elderly. More data on risk groups for severe influenza in West Africa are needed to help shape influenza prevention and clinical management policies and guidelines.

  7. Rapid sample classification using an open port sampling interface coupled with liquid introduction atmospheric pressure ionization mass spectrometry.

    PubMed

    Van Berkel, Gary J; Kertesz, Vilmos

    2017-02-15

    An "Open Access"-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendor-provided software libraries. Sample classification based on spectral comparison utilized the spectral contrast angle method. Using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. This work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA.

  8. Isochromatic photoelasticity fringe patterns of PMMA in various shapes and stress applications

    NASA Astrophysics Data System (ADS)

    Manjit, Y.; Limpichaipanit, A.; Ngamjarurojana, A.

    2018-03-01

    The research focuses on isochromatic photoelastic fringe patterns in solid materials by using reflection mode in dark field polariscope. The optical setup consists of light source, polarizers, quarter wave plates, 577 nm optical pass filter, compensator and digital camera system. The fringe patterns were produced on the sample and fractional / integer number of fringe order was observed using Babinet compensator and digital camera system. The samples were circular and rectangular shape of PMMA coated with silver spray and compressed by hydraulic system at the top and the bottom. The results of the isochromatic fringe pattern were analyzed in horizontal and vertical positions. It was found that force and the number of isochromatic photoelastic fringe order depended on shape of sample, which reflects stress distribution behavior.

  9. System for determining position of normal shock in supersonic flow

    NASA Technical Reports Server (NTRS)

    Iverson, Jr., Donald G. (Inventor); Daiber, Troy D. (Inventor)

    1991-01-01

    Light from a plurality of light emitting diodes is transmitted through optical cables (12) to a lens system. The lenses (56, 58) expand and collimate the light and project it in a sheet (16) across the supersonic inlet of an aircraft power plant perpendicular to incoming airflow. A normal shock bends a portion of the sheet of light (16). A linear array of a multiplicity of optical fiber ends collects discrete samples of light. The samples are processed and compared to a predetermined profile to determine the shock location.

  10. Alignment and position visualization methods for the biomedical imaging and therapy (BMIT) MRT lift

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bree, Michael, E-mail: michael.bree@lightsource.ca; Miller, Denise; Kerr, Graham

    The Microbeam Radiation Therapy (MRT) Lift is an eight stage positioning and scanning system at the Canadian Light Source’s BMIT Facility. Alignment of the sample with the beam using the MRT Lift is a time consuming and challenging task. The BMIT Group has developed a Python-based MRT Lift positioning and control program that uses a combination of computational and iterative methods to independently adjust the sample’s X, Y, Z, pitch and roll positions. The program offers “1-Click” alignment of the sample to the beam. Use of a wireframe visualization technique enables even minute movements to be illustrated. Proposed movements andmore » the resulting MRT Lift position can be manually verified before being applied. Optional integration with the SolidWorks modelling platform allows high quality renderings of the MRT Lift in its current or proposed position to be displayed in real time. Human factors principles are incorporated into the program with the objective of delivering easy to use controls for this complex device.« less

  11. Use of one-ply composite tissues in an automated optical assay for recovery of Listeria from food contact surfaces and poultry-processing environments.

    PubMed

    Yan, Zhinong; Vorst, Keith L; Zhang, Lei; Ryser, Elliot T

    2007-05-01

    A novel one-ply composite tissue (CT) method using the Soleris (formerly BioSys) optical analysis system was compared with the conventional U.S. Department of Agriculture (USDA) environmental sponge enrichment method for recovery of Listeria from food contact surfaces and poultry-processing environments. Stainless steel and high-density polyethylene plates were inoculated to contain a six-strain L. monocytogenes cocktail at 10(4), 10(2), and 10 CFU per plate, whereas samples from naturally contaminated surfaces and floor drains from a poultry-processing facility were collected with CTs and environmental sponges. CT samples were transferred into Soleris system vials, and presumptive-positive samples were further confirmed. Sponge samples were processed for Listeria using the USDA culture method. L. monocytogenes recovery rates from inoculated stainless steel and polyethylene surfaces were then compared for the two methods in terms of sensitivity, specificity, and positive and negative predictive values. No significant differences (P > 0.05) were found between the two methods for recovery of L. monocytogenes from any of the inoculated stainless steel and polyethylene surfaces or environmental samples. Sensitivity, specificity, and overall accuracy of the CT-Soleris for recovery of Listeria from environmental samples were 83, 97, and 95%, respectively. Listeria was detected 2 to 3 days sooner with the CT-Soleris method than with the USDA culture method, thus supporting the increased efficacy of this new protocol for environmental sampling.

  12. Design and Elementary Evaluation of a Highly-Automated Fluorescence-Based Instrument System for On-Site Detection of Food-Borne Pathogens

    PubMed Central

    Lu, Zhan; Zhang, Jianyi; Xu, Lizhou; Li, Yanbin; Chen, Siyu; Ye, Zunzhong; Wang, Jianping

    2017-01-01

    A simple, highly-automated instrument system used for on-site detection of foodborne pathogens based on fluorescence was designed, fabricated, and preliminarily tested in this paper. A corresponding method has been proved effective in our previous studies. This system utilizes a light-emitting diode (LED) to excite fluorescent labels and a spectrometer to record the fluorescence signal from samples. A rotation stage for positioning and switching samples was innovatively designed for high-throughput detection, ten at most in one single run. We also developed software based on LabVIEW for data receiving, processing, and the control of the whole system. In the test of using a pure quantum dot (QD) solution as a standard sample, detection results from this home-made system were highly-relevant with that from a well-commercialized product and even slightly better reproducibility was found. And in the test of three typical kinds of food-borne pathogens, fluorescence signals recorded by this system are highly proportional to the variation of the sample concentration, with a satisfied limit of detection (LOD) (nearly 102–103 CFU·mL−1 in food samples). Additionally, this instrument system is low-cost and easy-to-use, showing a promising potential for on-site rapid detection of food-borne pathogens. PMID:28241478

  13. Design and Elementary Evaluation of a Highly-Automated Fluorescence-Based Instrument System for On-Site Detection of Food-Borne Pathogens.

    PubMed

    Lu, Zhan; Zhang, Jianyi; Xu, Lizhou; Li, Yanbin; Chen, Siyu; Ye, Zunzhong; Wang, Jianping

    2017-02-23

    A simple, highly-automated instrument system used for on-site detection of foodborne pathogens based on fluorescence was designed, fabricated, and preliminarily tested in this paper. A corresponding method has been proved effective in our previous studies. This system utilizes a light-emitting diode (LED) to excite fluorescent labels and a spectrometer to record the fluorescence signal from samples. A rotation stage for positioning and switching samples was innovatively designed for high-throughput detection, ten at most in one single run. We also developed software based on LabVIEW for data receiving, processing, and the control of the whole system. In the test of using a pure quantum dot (QD) solution as a standard sample, detection results from this home-made system were highly-relevant with that from a well-commercialized product and even slightly better reproducibility was found. And in the test of three typical kinds of food-borne pathogens, fluorescence signals recorded by this system are highly proportional to the variation of the sample concentration, with a satisfied limit of detection (LOD) (nearly 10²-10³ CFU·mL -1 in food samples). Additionally, this instrument system is low-cost and easy-to-use, showing a promising potential for on-site rapid detection of food-borne pathogens.

  14. [The comparative study of specificity of test-systems in diagnostic of HIV-infection on categories of samples of blood serum of pregnant women].

    PubMed

    Sharipova, I N; Khodak, N M; Puzirev, V F; Burkov, A N; Ulanova, T I

    2015-03-01

    The detection of false positive serological reactions (FPSR) on HIV-infection under screening examination of pregnant women is an actual problem of practical health care. The original observations testify that under analysis of the same samples of blood serum of pregnant women using screening immune enzyme test-systems of various manufacturers the unmatched data concerning FPSR can be obtained. The purpose of this study was to implement comparative evaluation of specificity of immune enzyme test-systems of three different manufacturers: "DS-IFA-HIV-AGAT-SCREEN" ("Diagnostic Systems"), "Genscreen Ultra HIV Ag-Ab" "Bio Rad" France) and "The CombiBest HIV-1,2 AG/AT" ("Vector-Best" Novosibirsk). The sampling of 440 samples of blood serums of pregnant women from various medical institutions of Nizhnii Novgorod was analyzed. The results of the study demonstrated that FPSR were detected in all test-systems and at that spectrum of samples differed. The identical specificity of compared test-systems amounted to 98.64%. The alternative approach to FPSR to HIV issue under screening examinations of pregnant women was proposed. The proposed mode consisted of consistent application of two test-systems of fourth generation with different format of setup of reaction.

  15. Analysis of rabies diagnosis in dogs and cats in the state of São Paulo, Brazil.

    PubMed

    Castilho, Juliana Galera; Achkar, Samira Maria; de Novaes Oliveira, Rafael; Mori, Enio; Carnieli, Pedro; Macedo, Carla Isabel

    2018-05-08

    The genetic lineage of rabies virus (RABV) associated with dogs has not been found in the state of São Paulo since 1998, and all cases of rabies in domestic animals reported since then have involved the RABV lineage that circulates in bats. As there has been a change in the rabies transmission cycle in cats and dogs, we decided to analyze the tests used to diagnose rabies in these animals in the 15-year period from 2002 to 2016 in the state of São Paulo. During this period, 85,508 central nervous system (CNS) samples from dogs and cats were submitted to the Rabies Diagnosis Section at the Pasteur Institute of São Paulo for testing. All of the samples were tested by the fluorescent antibody test (FAT) and at least one of the following three tests: mouse inoculation test (MIT), rabies tissue culture infection test (RTCIT) and reverse transcription polymerase chain reaction (RT-PCR). Of all the samples tested, twenty were positive in at least one of these assays. Four other positive samples were identified at other institutions in the state of São Paulo. Of the twenty samples that tested positive at the Pasteur Institute of São Paulo, nine were tested by FAT, and the results were subsequently confirmed by other techniques; five gave inconclusive results, and therefore, other techniques had to be used as soon as possible in case the samples were positive; and six were negative by FAT and positive by one or more of the following tests: RTCIT, MIT and RT-PCR. Genetic typing of isolates from eighteen samples identified them as the lineage circulating in bats. In light of this finding, which indicates that genetic lineages associated with bats are circulating in domestic animals in the state of São Paulo, when the results of FAT carried out with samples from aggressive cats and dogs are inconclusive, complementary tests should be used. Decomposing samples and samples for which FAT was inconclusive should be tested using molecular techniques so that a definitive result can be obtained quickly and timely post-exposure prophylaxis can be administered to exposed individuals.

  16. In-situ X-ray diffraction system using sources and detectors at fixed angular positions

    DOEpatents

    Gibson, David M [Voorheesville, NY; Gibson, Walter M [Voorheesville, NY; Huang, Huapeng [Latham, NY

    2007-06-26

    An x-ray diffraction technique for measuring a known characteristic of a sample of a material in an in-situ state. The technique includes using an x-ray source for emitting substantially divergent x-ray radiation--with a collimating optic disposed with respect to the fixed source for producing a substantially parallel beam of x-ray radiation by receiving and redirecting the divergent paths of the divergent x-ray radiation. A first x-ray detector collects radiation diffracted from the sample; wherein the source and detector are fixed, during operation thereof, in position relative to each other and in at least one dimension relative to the sample according to a-priori knowledge about the known characteristic of the sample. A second x-ray detector may be fixed relative to the first x-ray detector according to the a-priori knowledge about the known characteristic of the sample, especially in a phase monitoring embodiment of the present invention.

  17. Local synchronization of chaotic neural networks with sampled-data and saturating actuators.

    PubMed

    Wu, Zheng-Guang; Shi, Peng; Su, Hongye; Chu, Jian

    2014-12-01

    This paper investigates the problem of local synchronization of chaotic neural networks with sampled-data and actuator saturation. A new time-dependent Lyapunov functional is proposed for the synchronization error systems. The advantage of the constructed Lyapunov functional lies in the fact that it is positive definite at sampling times but not necessarily between sampling times, and makes full use of the available information about the actual sampling pattern. A local stability condition of the synchronization error systems is derived, based on which a sampled-data controller with respect to the actuator saturation is designed to ensure that the master neural networks and slave neural networks are locally asymptotically synchronous. Two optimization problems are provided to compute the desired sampled-data controller with the aim of enlarging the set of admissible initial conditions or the admissible sampling upper bound ensuring the local synchronization of the considered chaotic neural networks. A numerical example is used to demonstrate the effectiveness of the proposed design technique.

  18. Evaluation of culture- and PCR-based detection methods for Escherichia coli O157:H7 in inoculated ground beeft.

    PubMed

    Arthur, Terrance M; Bosilevac, Joseph M; Nou, Xiangwu; Koohmaraie, Mohammad

    2005-08-01

    Currently, several beef processors employ test-and-hold systems for increased quality control of ground beef. In such programs, each lot of product must be tested and found negative for Escherichia coli O157:H7 prior to release of the product into commerce. Optimization of three testing attributes (detection time, specificity, and sensitivity) is critical to the success of such strategies. Because ground beef is a highly perishable product, the testing methodology used must be as rapid as possible. The test also must have a low false-positive result rate so product is not needlessly discarded. False-negative results cannot be tolerated because they would allow contaminated product to be released and potentially cause disease. In this study, two culture-based and three PCR-based methods for detecting E. coli O157:H7 in ground beef were compared for their abilities to meet the above criteria. Ground beef samples were individually spiked with five genetically distinct strains of E. coli O157: H7 at concentrations of 17 and 1.7 CFU/65 g and then subjected to the various testing methodologies. There was no difference (P > 0.05) in the abilities of the PCR-based methods to detect E. coli O157:H7 inoculated in ground beef at 1.7 CFU/65 g. The culture-based systems detected more positive samples than did the PCR-based systems, but the detection times (21 to 48 h) were at least 9 h longer than those for the PCR-based methods (7.5 to 12 h). Ground beef samples were also spiked with potentially cross-reactive strains. The PCR-based systems that employed an immunomagnetic separation step prior to detection produced fewer false-positive results.

  19. Ultra wideband ground penetrating radar imaging of heterogeneous solids

    DOEpatents

    Warhus, J.P.; Mast, J.E.

    1998-11-10

    A non-invasive imaging system for analyzing engineered structures comprises pairs of ultra wideband radar transmitters and receivers in a linear array that are connected to a timing mechanism that allows a radar echo sample to be taken at a variety of delay times for each radar pulse transmission. The radar transmitters and receivers are coupled to a position determining system that provides the x,y position on a surface for each group of samples measured for a volume from the surface. The radar transmitter and receivers are moved about the surface, e.g., attached to the bumper of a truck, to collect such groups of measurements from a variety of x,y positions. Return signal amplitudes represent the relative reflectivity of objects within the volume and the delay in receiving each signal echo represents the depth at which the object lays in the volume and the propagation speeds of the intervening material layers. Successively deeper z-planes are backward propagated from one layer to the next with an adjustment for variations in the expected propagation velocities of the material layers that lie between adjacent z-planes. 11 figs.

  20. Ultra wideband ground penetrating radar imaging of heterogeneous solids

    DOEpatents

    Warhus, John P.; Mast, Jeffrey E.

    1998-01-01

    A non-invasive imaging system for analyzing engineered structures comprises pairs of ultra wideband radar transmitters and receivers in a linear array that are connected to a timing mechanism that allows a radar echo sample to be taken at a variety of delay times for each radar pulse transmission. The radar transmitters and receivers are coupled to a position determining system that provides the x,y position on a surface for each group of samples measured for a volume from the surface. The radar transmitter and receivers are moved about the surface, e.g., attached to the bumper of a truck, to collect such groups of measurements from a variety of x,y positions. Return signal amplitudes represent the relative reflectivity of objects within the volume and the delay in receiving each signal echo represents the depth at which the object lays in the volume and the propagation speeds of the intervening material layers. Successively deeper z-planes are backward propagated from one layer to the next with an adjustment for variations in the expected propagation velocities of the material layers that lie between adjacent z-planes.

  1. Combined Falling Drop/Open Port Sampling Interface System for Automated Flow Injection Mass Spectrometry

    DOE PAGES

    Van Berkel, Gary J.; Kertesz, Vilmos; Orcutt, Matt; ...

    2017-11-07

    The aim of this work was to demonstrate and to evaluate the analytical performance of a combined falling drop/open port sampling interface (OPSI) system as a simple noncontact, no-carryover, automated system for flow injection analysis with mass spectrometry. The falling sample drops were introduced into the OPSI using a widely available autosampler platform utilizing low cost disposable pipet tips and conventional disposable microtiter well plates. The volume of the drops that fell onto the OPSI was in the 7–15 μL range with an injected sample volume of several hundred nanoliters. Sample drop height, positioning of the internal capillary on themore » sampling end of the probe, and carrier solvent flow rate were optimized for maximum signal. Sample throughput, signal reproducibility, matrix effects, and quantitative analysis capability of the system were established using the drug molecule propranolol and its isotope labeled internal standard in water, unprocessed river water and two commercially available buffer matrices. A sample-to-sample throughput of ~45 s with a ~4.5 s base-to-base flow injection peak profile was obtained in these experiments. In addition, quantitation with minimally processed rat plasma samples was demonstrated with three different statin drugs (atorvastatin, rosuvastatin, and fluvastatin). Direct characterization capability of unprocessed samples was demonstrated by the analysis of neat vegetable oils. Employing the autosampler system for spatially resolved liquid extraction surface sampling exemplified by the analysis of propranolol and its hydroxypropranolol glucuronide phase II metabolites from a rat thin tissue section was also illustrated.« less

  2. Combined Falling Drop/Open Port Sampling Interface System for Automated Flow Injection Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Berkel, Gary J.; Kertesz, Vilmos; Orcutt, Matt

    The aim of this work was to demonstrate and to evaluate the analytical performance of a combined falling drop/open port sampling interface (OPSI) system as a simple noncontact, no-carryover, automated system for flow injection analysis with mass spectrometry. The falling sample drops were introduced into the OPSI using a widely available autosampler platform utilizing low cost disposable pipet tips and conventional disposable microtiter well plates. The volume of the drops that fell onto the OPSI was in the 7–15 μL range with an injected sample volume of several hundred nanoliters. Sample drop height, positioning of the internal capillary on themore » sampling end of the probe, and carrier solvent flow rate were optimized for maximum signal. Sample throughput, signal reproducibility, matrix effects, and quantitative analysis capability of the system were established using the drug molecule propranolol and its isotope labeled internal standard in water, unprocessed river water and two commercially available buffer matrices. A sample-to-sample throughput of ~45 s with a ~4.5 s base-to-base flow injection peak profile was obtained in these experiments. In addition, quantitation with minimally processed rat plasma samples was demonstrated with three different statin drugs (atorvastatin, rosuvastatin, and fluvastatin). Direct characterization capability of unprocessed samples was demonstrated by the analysis of neat vegetable oils. Employing the autosampler system for spatially resolved liquid extraction surface sampling exemplified by the analysis of propranolol and its hydroxypropranolol glucuronide phase II metabolites from a rat thin tissue section was also illustrated.« less

  3. High pressure system for 3-D study of elastic anisotropy

    NASA Astrophysics Data System (ADS)

    Lokajicek, T.; Pros, Z.; Klima, K.

    2003-04-01

    New high pressure system was designed for the study of elastic anisotropy of condensed matter under high confining pressure up to 700 MPa. Simultaneously could be measured dynamic and static parameters: a) dynamic parameters by ultrasonic sounding, b) static parameters by measuring of spherical sample deformation. The measurement is carried out on spherical samples diameter 50 +/- 0.01 mm. Higher value of confining pressure was reached due to the new construction of sample positioning unit. The positioning unit is equipped with two Portecap step motors, which are located inside the vessel and make possible to rotate with the sphere and couple of piezoceramic transducers. Sample deformation is measured in the same direction as ultrasonic signal travel time. Only electric leads connects inner part of high pressure vessel with surrounding environment. Experimental set up enables: - simultaneous P-wave ultrasonic sounding, - measurement of current sample deformation at sounding points, - measurement of current value of confining pressure and - measurement of current stress media temperature. Air driven high pressure pump Haskel is used to produce high value of confining pressure up to 700 MPa. Ultrasonic signals are recorded by digital scope Agilent 54562 with sampling frequency 100 MHz. Control and measuring software was developed under Agilent VEE software environment working under MS Win 2000 operating system. Measuring set up was tested by measurement of monomineral spherical samples of quartz and corundum. Both of them have trigonal symmetry. The measurement showed that the P-wave velocity range of quartz was between 5.7-7.0 km/sec. and velocity range of corundum was between 9.7-10.9 km/sec. High pressure resistant LVDT transducers Mesing together with Intronix electronic unit were used to monitor sample deformation. Sample deformation is monitored with the accuracy of 0.1 micron. All test measurements proved the good accuracy of the whole measuring set up. This project was supported by Grant Agency of the Czech Republic No.: 205/01/1430.

  4. [Anaerobic bacteria isolated from patients with suspected anaerobic infections].

    PubMed

    Ercis, Serpil; Tunçkanat, Ferda; Hasçelik, Gülşen

    2005-10-01

    The study involved 394 clinical samples sent to the Clinical Microbiology Laboratory of Hacettepe University Adult Hospital between January 1997 and May 2004 for anaerobic cultivation. Since multiple cultures from the same clinical samples of the same patient were excluded, the study was carried on 367 samples. The anaerobic cultures were performed in anaerobic jar using AnaeroGen kits (Oxoid, Basingstoke, U.K.) or GENbox (bioMérieux, Lyon, France). The isolates were identified by both classical methods and "BBL Crystal System" (Becton Dickinson, U.S.A.). While no growth was detected in 120 (32.7%) of the clinical samples studied, in 144 samples (39.2%) only aerobes, in 28 (7.6%) only anaerobes and in 75 (20.5%) of the samples both aerobes and anaerobes were isolated. The number of the anaerobic isolates was 217 from 103 samples with anaerobic growth. Of these 103 samples 15 showed single bacterial growth whereas in 88 samples multiple bacterial isolates were detected. Anaerobic isolates consisted of 92 Gram negative bacilli (Bacteroides spp. 50, Prevotella spp. 14, Porphyromonas spp. 10, Fusobacterium spp. 7, Tisierella spp. 2, unidentified 9), 57 Gram positive bacilli (Clostridium spp.17, Propionibacterium spp. 16, Lactobacillus spp. 8, Actinomyces spp. 5, Eubacterium spp. 2, Bifidobacterium adolescentis 1, Mobiluncus mulieris 1, unidentified nonspore forming rods 7), 61 Gram positive cocci (anaerobic cocci 44, microaerophilic cocci 17), and 7 Gram negative cocci (Veillonella spp.). In conclusion, in the samples studied with prediagnosis of anaerobic infection, Bacteroides spp. (23%) were the most common bacteria followed by anaerobic Gram positive cocci (20.3%) and Clostridium spp (7.8%).

  5. Face mask sampling for the detection of Mycobacterium tuberculosis in expelled aerosols.

    PubMed

    Williams, Caroline M L; Cheah, Eddy S G; Malkin, Joanne; Patel, Hemu; Otu, Jacob; Mlaga, Kodjovi; Sutherland, Jayne S; Antonio, Martin; Perera, Nelun; Woltmann, Gerrit; Haldar, Pranabashis; Garton, Natalie J; Barer, Michael R

    2014-01-01

    Although tuberculosis is transmitted by the airborne route, direct information on the natural output of bacilli into air by source cases is very limited. We sought to address this through sampling of expelled aerosols in face masks that were subsequently analyzed for mycobacterial contamination. In series 1, 17 smear microscopy positive patients wore standard surgical face masks once or twice for periods between 10 minutes and 5 hours; mycobacterial contamination was detected using a bacteriophage assay. In series 2, 19 patients with suspected tuberculosis were studied in Leicester UK and 10 patients with at least one positive smear were studied in The Gambia. These subjects wore one FFP30 mask modified to contain a gelatin filter for one hour; this was subsequently analyzed by the Xpert MTB/RIF system. In series 1, the bacteriophage assay detected live mycobacteria in 11/17 patients with wearing times between 10 and 120 minutes. Variation was seen in mask positivity and the level of contamination detected in multiple samples from the same patient. Two patients had non-tuberculous mycobacterial infections. In series 2, 13/20 patients with pulmonary tuberculosis produced positive masks and 0/9 patients with extrapulmonary or non-tuberculous diagnoses were mask positive. Overall, 65% of patients with confirmed pulmonary mycobacterial infection gave positive masks and this included 3/6 patients who received diagnostic bronchoalveolar lavages. Mask sampling provides a simple means of assessing mycobacterial output in non-sputum expectorant. The approach shows potential for application to the study of airborne transmission and to diagnosis.

  6. Face Mask Sampling for the Detection of Mycobacterium tuberculosis in Expelled Aerosols

    PubMed Central

    Malkin, Joanne; Patel, Hemu; Otu, Jacob; Mlaga, Kodjovi; Sutherland, Jayne S.; Antonio, Martin; Perera, Nelun; Woltmann, Gerrit; Haldar, Pranabashis; Garton, Natalie J.; Barer, Michael R.

    2014-01-01

    Background Although tuberculosis is transmitted by the airborne route, direct information on the natural output of bacilli into air by source cases is very limited. We sought to address this through sampling of expelled aerosols in face masks that were subsequently analyzed for mycobacterial contamination. Methods In series 1, 17 smear microscopy positive patients wore standard surgical face masks once or twice for periods between 10 minutes and 5 hours; mycobacterial contamination was detected using a bacteriophage assay. In series 2, 19 patients with suspected tuberculosis were studied in Leicester UK and 10 patients with at least one positive smear were studied in The Gambia. These subjects wore one FFP30 mask modified to contain a gelatin filter for one hour; this was subsequently analyzed by the Xpert MTB/RIF system. Results In series 1, the bacteriophage assay detected live mycobacteria in 11/17 patients with wearing times between 10 and 120 minutes. Variation was seen in mask positivity and the level of contamination detected in multiple samples from the same patient. Two patients had non-tuberculous mycobacterial infections. In series 2, 13/20 patients with pulmonary tuberculosis produced positive masks and 0/9 patients with extrapulmonary or non-tuberculous diagnoses were mask positive. Overall, 65% of patients with confirmed pulmonary mycobacterial infection gave positive masks and this included 3/6 patients who received diagnostic bronchoalveolar lavages. Conclusion Mask sampling provides a simple means of assessing mycobacterial output in non-sputum expectorant. The approach shows potential for application to the study of airborne transmission and to diagnosis. PMID:25122163

  7. ALK status testing in non-small cell lung carcinoma: correlation between ultrasensitive IHC and FISH.

    PubMed

    Minca, Eugen C; Portier, Bryce P; Wang, Zhen; Lanigan, Christopher; Farver, Carol F; Feng, Yan; Ma, Patrick C; Arrossi, Valeria A; Pennell, Nathan A; Tubbs, Raymond R

    2013-05-01

    ALK gene rearrangements in advanced non-small cell lung carcinomas (NSCLC) are an indication for targeted therapy with crizotinib. Fluorescence in situ hybridization (FISH) using a recently approved companion in vitro diagnostic class FISH system commonly assesses ALK status. More accessible IHC is challenged by low expression of ALK-fusion transcripts in NSCLC. We compared ultrasensitive automated IHC with FISH for detecting ALK status on 318 FFPE and 40 matched ThinPrep specimens from 296 patients with advanced NSCLC. IHC was concordant with FFPE-FISH on 229 of 231 dual-informative samples (31 positive and 198 negative) and with ThinPrep-FISH on 34 of 34 samples (5 positive and 29 negative). Two cases with negative IHC and borderline-positive FFPE-FISH (15% and 18%, respectively) were reclassified as concordant based on negative matched ThinPrep-FISH and clinical data consistent with ALK-negative status. Overall, after including ThinPrep-FISH and amending the false-positive FFPE-FISH results, IHC demonstrated 100% sensitivity and specificity (95% CI, 0.86 to 1.00 and 0.97 to 1.00, respectively) for ALK detection on 249 dual-informative NSCLC samples. IHC was informative on significantly more samples than FFPE-FISH, revealing additional ALK-positive cases. The high concordance with FISH warrants IHC's routine use as the initial component of an algorithmic approach to clinical ALK testing in NSCLC, followed by reflex FISH confirmation of IHC-positive cases. Copyright © 2013 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  8. Feasibility Study for an Autonomous UAV - Magnetometer System

    DTIC Science & Technology

    2007-11-01

    collect data from multiple magnetometers at high sampling rates (~100 Hz), and associated with these acquisition systems are highly accurate...component for an UAV helicopter- magnetometer system is the ability to have precise positioning (both for flightpath execution and for data acquisition...discussed under section 6.3. Figure 6.11 shows the fluxgate data used to compensate a total field magnetometer as previously described. The red

  9. Vimentin and Ki67 expression in circulating tumour cells derived from castrate-resistant prostate cancer.

    PubMed

    Lindsay, C R; Le Moulec, S; Billiot, F; Loriot, Y; Ngo-Camus, M; Vielh, P; Fizazi, K; Massard, C; Farace, F

    2016-02-29

    High circulating tumor cell (CTC) counts are associated with poor prognosis in advanced prostate cancer, and recently CTC number was suggested to be a surrogate for survival in metastatic castrate-resistant prostate cancer (mCRPC). Ki67 and vimentin are well-characterised markers of tumour cell proliferation and the epithelial-mesenchymal transition (EMT), respectively. Here we asked if the expression of vimentin and Ki67 in CTCs offered prognostic or predictive information in mCRPC. In two separate patient cohorts, anti-vimentin or anti-Ki67 antibodies were added to the free channel in the CellSearch® system for analysis of peripheral blood samples. For each cohort, association of CTC number with clinical characteristics were assessed using Fisher's exact, Mann-Whitney and chi-squared tests. Kaplan-Meier method and log-rank tests were used to analyse overall survival (OS) of vimentin-expressing and Ki67-expressing CTC patient cohorts. In this retrospective analysis, CTC vimentin expression was analysed in 142 blood samples from 93 patients, and CTC Ki67 expression was analysed in 90 blood samples from 51 patients. In the vimentin cohort, 80/93 (86 %) of baseline samples from patients were CTC-positive overall (≥1 total CTC per 7.5 mls blood), and 30/93 (32.3 %) vimentin CTC-positive (≥1 vimentin-positive CTC per 7.5 mls blood). 41/51 (80.4 %) of baseline samples from patients in the Ki67 cohort were CTC-positive overall, and 23/51 (45.1 %) Ki67 CTC-positive (≥1 Ki67-positive CTC per 7.5 mls blood). There was no significant difference in baseline PSA in patients with vimentin-positive CTC at baseline versus those with no vimentin-positive CTC at baseline (p = 0.33). A significant reduction in OS was shown in patients with vimentin-positive CTC compared to those without vimentin-positive CTC (median 305 days vs 453 days, p = 0.0293). There was no significant difference in baseline PSA in patients with Ki67-positive CTC at baseline versus those without Ki67-positive CTC (p = 0.228), but OS was significantly reduced in the Ki67-positive CTC group (median 512 days vs 751 days, p = 0.0091). No changes in relative proportion of vimentin- or Ki67-positive CTCs were observed in post-treatment samples compared to baseline. Analysis of vimentin and Ki67 expression can straightforwardly be assessed in CTCs from patients with mCRPC. Poorer survival outcomes were observed in vimentin- and Ki67-positive CTC patients. CEC-CTC (IDRCB2008-AOO585-50) and Petrus ( NCT01786031 ).

  10. Development of a hybrid atomic force microscopic measurement system combined with white light scanning interferometry.

    PubMed

    Guo, Tong; Wang, Siming; Dorantes-Gonzalez, Dante J; Chen, Jinping; Fu, Xing; Hu, Xiaotang

    2012-01-01

    A hybrid atomic force microscopic (AFM) measurement system combined with white light scanning interferometry for micro/nanometer dimensional measurement is developed. The system is based on a high precision large-range positioning platform with nanometer accuracy on which a white light scanning interferometric module and an AFM head are built. A compact AFM head is developed using a self-sensing tuning fork probe. The head need no external optical sensors to detect the deflection of the cantilever, which saves room on the head, and it can be directly fixed under an optical microscopic interferometric system. To enhance the system's dynamic response, the frequency modulation (FM) mode is adopted for the AFM head. The measuring data can be traceable through three laser interferometers in the system. The lateral scanning range can reach 25 mm × 25 mm by using a large-range positioning platform. A hybrid method combining AFM and white light scanning interferometry is proposed to improve the AFM measurement efficiency. In this method, the sample is measured firstly by white light scanning interferometry to get an overall coarse morphology, and then, further measured with higher resolution by AFM. Several measuring experiments on standard samples demonstrate the system's good measurement performance and feasibility of the hybrid measurement method.

  11. Diffraction patterns in Fresnel approximation of periodic objects for a colorimeter of two apertures

    NASA Astrophysics Data System (ADS)

    Cortes-Reynoso, Jose-German R.; Suarez-Romero, Jose G.; Hurtado-Ramos, Juan B.; Tepichin-Rodriguez, Eduardo; Solorio-Leyva, Juan Carlos

    2004-10-01

    In this work, we present a study of Fresnel diffraction of periodic structures in an optical system of two apertures. This system of two apertures was used successfully for measuring color in textile samples solving the problems of illumination and directionality that present current commercial equipments. However, the system is sensible to the spatial frequency of the periodic sample"s area enclosed in its optical field of view. The study of Fresnel diffraction allows us to establish criteria for geometrical parameters of measurements in order to assure invariance in angular rotations and spatial positions. In this work, we use the theory of partial coherence to calculate the diffraction through two continuous apertures. In the calculation process, we use the concept of point-spread function of the system for partial coherence, in this way we avoid complicated statistical processes commonly used in the partial coherence theory.

  12. Combined, solid-state molecular property and gamma spectrometers for CBRNE detection

    NASA Astrophysics Data System (ADS)

    Rogers, Ben; Grate, Jay; Pearson, Brett; Gallagher, Neal; Wise, Barry; Whitten, Ralph; Adams, Jesse

    2013-05-01

    Nevada Nanotech Systems, Inc. (Nevada Nano) has developed a multi-sensor solution to Chemical, Biological, Radiological, Nuclear and Explosives (CBRNE) detection that combines the Molecular Property Spectrometer™ (MPS™)—a micro-electro-mechanical chip-based technology capable of measuring a variety of thermodynamic and electrostatic molecular properties of sampled vapors and particles—and a compact, high-resolution, solid-state gamma spectrometer module for identifying radioactive materials, including isotopes used in dirty bombs and nuclear weapons. By conducting multiple measurements, the system can provide a more complete characterization of an unknown sample, leading to a more accurate identification. Positive identifications of threats are communicated using an integrated wireless module. Currently, system development is focused on detection of commercial, military and improvised explosives, radioactive materials, and chemical threats. The system can be configured for a variety of CBRNE applications, including handheld wands and swab-type threat detectors requiring short sample times, and ultra-high sensitivity detectors in which longer sampling times are used. Here we provide an overview of the system design and operation and present results from preliminary testing.

  13. Estimation in a discrete tail rate family of recapture sampling models

    NASA Technical Reports Server (NTRS)

    Gupta, Rajan; Lee, Larry D.

    1990-01-01

    In the context of recapture sampling design for debugging experiments the problem of estimating the error or hitting rate of the faults remaining in a system is considered. Moment estimators are derived for a family of models in which the rate parameters are assumed proportional to the tail probabilities of a discrete distribution on the positive integers. The estimators are shown to be asymptotically normal and fully efficient. Their fixed sample properties are compared, through simulation, with those of the conditional maximum likelihood estimators.

  14. (Not) talking about sex: a systematic comparison of sexual impairment in women with systemic sclerosis and other chronic disease samples.

    PubMed

    Knafo, Ruby; Thombs, Brett D; Jewett, Lisa; Hudson, Marie; Wigley, Fred; Haythornthwaite, Jennifer A

    2009-10-01

    Sexual impairment in women with SSc has received little attention. The objective of this study was to compare levels of sexual impairment in women with SSc with samples of women with medical illnesses for which sexual impairment has been researched more extensively. SSc patients completed the Sexual Relationships subscale of the Psychosocial Adjustment to Illness Scale-Self-Report (PAIS-SR). A systematic review was conducted to select comparison samples. Sexual Relationships subscale scores from SSc patients were compared with scores from comparison samples (breast or gynaecological cancer and HIV) using t-tests and Hedges's g to calculate effect sizes. Samples from 138 female SSc patients were analysed (28.3% diffuse; mean age 52.1 +/- 12.3 years; mean time since diagnosis 9.0 +/- 8.3 years). Women with dcSSc (6.1 +/- 4.2) reported significantly greater sexual impairment (P < 0.05) than those with lcSSc (4.4 +/- 4.2), three breast cancer samples (1.8 +/- 0.1, 3.4 +/- 3.9, 1.6 +/- 0.6) and two samples of HIV-positive female patients (4.4 +/- 3.8, 4.5 +/- 3.9). Scores in dcSSc were similar to one sample of HIV-positive women (5.8 +/- 4.1) and gynaecological cancer patients (7.3 +/- 4.3). Scores in lcSSc were significantly higher than two breast cancer samples, similar to one breast cancer sample and two HIV-positive samples, and significantly lower (P < 0.05) than in one HIV sample and gynaecological cancer. Women with SSc, particularly those with dcSSc, have high levels of sexual impairment compared with women with other chronic diseases, where sexual function has received greater attention. Further research is needed on sexual function among women with SSc.

  15. X-ray transport and radiation response assessment (XTRRA) experiments at the National Ignition Facility.

    PubMed

    Fournier, K B; Brown, C G; Yeoman, M F; Fisher, J H; Seiler, S W; Hinshelwood, D; Compton, S; Holdener, F R; Kemp, G E; Newlander, C D; Gilliam, R P; Froula, N; Lilly, M; Davis, J F; Lerch, Maj A; Blue, B E

    2016-11-01

    Our team has developed an experimental platform to evaluate the x-ray-generated stress and impulse in materials. Experimental activities include x-ray source development, design of the sample mounting hardware and sensors interfaced to the National Ignition Facility's diagnostics insertion system, and system integration into the facility. This paper focuses on the X-ray Transport and Radiation Response Assessment (XTRRA) test cassettes built for these experiments. The test cassette is designed to position six samples at three predetermined distances from the source, each known to within ±1% accuracy. Built-in calorimeters give in situ measurements of the x-ray environment along the sample lines of sight. The measured accuracy of sample responses as well as planned modifications to the XTRRA cassette is discussed.

  16. Search for Minimal and Semi-Minimal Rule Sets in Incremental Learning of Context-Free and Definite Clause Grammars

    NASA Astrophysics Data System (ADS)

    Imada, Keita; Nakamura, Katsuhiko

    This paper describes recent improvements to Synapse system for incremental learning of general context-free grammars (CFGs) and definite clause grammars (DCGs) from positive and negative sample strings. An important feature of our approach is incremental learning, which is realized by a rule generation mechanism called “bridging” based on bottom-up parsing for positive samples and the search for rule sets. The sizes of rule sets and the computation time depend on the search strategies. In addition to the global search for synthesizing minimal rule sets and serial search, another method for synthesizing semi-optimum rule sets, we incorporate beam search to the system for synthesizing semi-minimal rule sets. The paper shows several experimental results on learning CFGs and DCGs, and we analyze the sizes of rule sets and the computation time.

  17. Adaptive reference voltage generator for firing angle control of line-commutated inverters

    NASA Technical Reports Server (NTRS)

    Dolland, C. R. (Inventor)

    1983-01-01

    A control system for a permanent-magnet motor driven by a multiphase line-commulated inverter is described. It is provided with integrators for integrating the back EMF of each phase of the motor for use in generating system control signals for an inverter gate logic using a sync and firing angle control generator connected to the outputs of the integrators. The firing angle control signals are produced by the control generator by means for combining 120 deg segments of the integrated back EMF signals symmetrical about their maxima into composite positive and negative waveforms, and means for sampling the maxima of each waveform every 120 deg. These samples are then used as positive and negative firing angle control signals. Whereby any change in amplitude of the integrated back EMF signals will not affect a change in the operating power factor of the motor and inverter.

  18. Environmental charging of spacecraft-tests of thermal control materials for use on the global positioning system flight space vehicle. Part 2: Specimen 6 to 9

    NASA Technical Reports Server (NTRS)

    Stevens, N. J.; Berkopec, F. D.; Blech, R. A.

    1976-01-01

    The NASA/USAF program on the Environmental Charging of Spacecraft Surfaces consists, in part, of experimental efforts directed toward evaluating the response of materials to the environmental charged particle flux. Samples of thermal blankets of the type to be used on the Global Positioning System Flight Space Vehicles were tested to determine their response to electron flux. The primary result observed was that no discharges were obtained with the quartz-fiber-fabric-covered multilayer insulation specimen. The taped aluminized polyester grounding system used on all specimens did not appear to grossly deteriorate with time; however, the specimens require specific external pressure to maintain constant grounding system resistance.

  19. Current Status of the Beam Position Monitoring System at TLS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuo, C. H.; Hu, K. H.; Chen, Jenny

    2006-11-20

    The beam position monitoring system is an important part of a synchrotron light source that supports its routine operation and studies of beam physics. The Taiwan light source is equipped with 59 BPMs. Highly precise closed orbits are measured by multiplexing BPMs. Data are acquired using multi-channel 16-bit ADC modules. Orbit data are sampled every millisecond. Fast orbit data are shared in a reflective memory network to support fast orbit feedback. Averaged data were updated to control database at a rate of 10 Hz. A few new generation digital BPMs were tested to evaluate their performance and functionality. This reportmore » summarizes the system structure, the software environment and the preliminary beam test of the BPM system.« less

  20. Current Status of the Beam Position Monitoring System at TLS

    NASA Astrophysics Data System (ADS)

    Kuo, C. H.; Hu, K. H.; Chen, Jenny; Lee, Demi; Wang, C. J.; Hsu, S. Y.; Hsu, K. T.

    2006-11-01

    The beam position monitoring system is an important part of a synchrotron light source that supports its routine operation and studies of beam physics. The Taiwan light source is equipped with 59 BPMs. Highly precise closed orbits are measured by multiplexing BPMs. Data are acquired using multi-channel 16-bit ADC modules. Orbit data are sampled every millisecond. Fast orbit data are shared in a reflective memory network to support fast orbit feedback. Averaged data were updated to control database at a rate of 10 Hz. A few new generation digital BPMs were tested to evaluate their performance and functionality. This report summarizes the system structure, the software environment and the preliminary beam test of the BPM system.

  1. Development of a Highly Sensitive Nested-PCR Procedure Using a Single Closed Tube for Detection of Erwinia amylovora in Asymptomatic Plant Material

    PubMed Central

    Llop, Pablo; Bonaterra, Anna; Peñalver, Javier; López, María M.

    2000-01-01

    A novel method, which involves a nested PCR in a single closed tube, was developed for the sensitive detection of Erwinia amylovora in plant material. The external and internal primer pairs used had different annealing temperatures and directed the amplification of a specific DNA fragment from plasmid pEA29. The procedure involved two consecutive PCRs, the first of which was performed at a higher annealing temperature that allowed amplification only by the external primer pair. Using pure cultures of E. amylovora, the sensitivity of the nested PCR in one tube was similar to that of a standard nested PCR in two tubes. The specificity and sensitivity were greater than those of standard PCR procedures that used a single primer pair. The presence of inhibitors in plant material, very common in E. amylovora hosts, is overcome with this system in combination with a simple DNA extraction protocol because it eliminates many of the inhibitory compounds. In addition, it needs a very small sample volume (1 μl of DNA extracted). With 83 samples of naturally infected material, this method achieved better results than any other PCR technique: standard PCR detected 55% of positive samples, two-tube nested PCR detected 71% of positive samples, and nested PCR in a single closed tube detected 78% of positive samples. When analyzing asymptomatic plant material, the number of positive samples detected by the developed nested PCR was also the highest, compared with the PCR protocols indicated previously (17, 20, and 25% of 251 samples analyzed, respectively). This method is proposed for the detection of endophytic and epiphytic populations of E. amylovora in epidemiological studies and for routine use in quarantine surveys, due to its high sensitivity, specificity, speed, and simplicity. PMID:10788384

  2. [Do lactoferrin, lysozyme and the lactoperoxidase-thiocyanate-hydrogen peroxide-system cause negative microbiological results in mastitis secretions?].

    PubMed

    Schmedt Auf Der Günne, H; Tenhagen, B A; Kutzer, P; Forderung, D; Heuwieser, W

    2002-07-01

    Lactoferrin, lysozyme and the lactoperoxidase-thiocyanate-peroxide-system are naturally occurring antimicrobial components of milk. The objective of this study was to examine, whether these components were responsible for negative results, when mastitis milk is cultured microbiologically. Quarter milk samples from 75 cows with clinical mastitis on a dairy farm in Brandenburg were submitted for microbiological culture and analysed for the content and the activities of the three components. Animals from all stages of lactation with clinical mastitis were included in the study. Animals were examined clinically and milk samples were collected prior to first treatment. Secretions from quarters with clinical mastitis were compared to those of neighbouring quarters without clinical mastitis. Secretions with positive cultural results were compared to those with negative results. The concentrations or activities of the three factors were significantly higher in the diseased quarters than in the quarters without clinical signs of mastitis. The concentration of lysozyme increased with severity of the clinical signs (local swelling and changes in secretion). The concentration of lactoferrin was significantly higher in quarters with slight alterations of glandular tissue than in quarters with medium or severe alterations (P < 0.05). LPS-activities did not correlate with the severity of clinical signs. No differences in the concentration of lactoferrin or LPS-activities were seen between mastitis with positive and negative culture results. The concentration of lysozyme was even higher in culturally positive samples than in negative samples (P < 0.05). Results from this study indicate that the three factors examined did not impair the results of microbiological culture of milk samples from quarters with clinical mastitis.

  3. Influence of Heart Rate in Non-linear HRV Indices as a Sampling Rate Effect Evaluated on Supine and Standing.

    PubMed

    Bolea, Juan; Pueyo, Esther; Orini, Michele; Bailón, Raquel

    2016-01-01

    The purpose of this study is to characterize and attenuate the influence of mean heart rate (HR) on nonlinear heart rate variability (HRV) indices (correlation dimension, sample, and approximate entropy) as a consequence of being the HR the intrinsic sampling rate of HRV signal. This influence can notably alter nonlinear HRV indices and lead to biased information regarding autonomic nervous system (ANS) modulation. First, a simulation study was carried out to characterize the dependence of nonlinear HRV indices on HR assuming similar ANS modulation. Second, two HR-correction approaches were proposed: one based on regression formulas and another one based on interpolating RR time series. Finally, standard and HR-corrected HRV indices were studied in a body position change database. The simulation study showed the HR-dependence of non-linear indices as a sampling rate effect, as well as the ability of the proposed HR-corrections to attenuate mean HR influence. Analysis in a body position changes database shows that correlation dimension was reduced around 21% in median values in standing with respect to supine position ( p < 0.05), concomitant with a 28% increase in mean HR ( p < 0.05). After HR-correction, correlation dimension decreased around 18% in standing with respect to supine position, being the decrease still significant. Sample and approximate entropy showed similar trends. HR-corrected nonlinear HRV indices could represent an improvement in their applicability as markers of ANS modulation when mean HR changes.

  4. Novel, improved sample preparation for rapid, direct identification from positive blood cultures using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry.

    PubMed

    Schubert, Sören; Weinert, Kirsten; Wagner, Chris; Gunzl, Beatrix; Wieser, Andreas; Maier, Thomas; Kostrzewa, Markus

    2011-11-01

    Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is widely used for rapid and reliable identification of bacteria and yeast grown on agar plates. Moreover, MALDI-TOF MS also holds promise for bacterial identification from blood culture (BC) broths in hospital laboratories. The most important technical step for the identification of bacteria from positive BCs by MALDI-TOF MS is sample preparation to remove blood cells and host proteins. We present a method for novel, rapid sample preparation using differential lysis of blood cells. We demonstrate the efficacy and ease of use of this sample preparation and subsequent MALDI-TOF MS identification, applying it to a total of 500 aerobic and anaerobic BCs reported to be positive by a Bactec 9240 system. In 86.5% of all BCs, the microorganism species were correctly identified. Moreover, in 18/27 mixed cultures at least one isolate was correctly identified. A novel method that adjusts the score value for MALDI-TOF MS results is proposed, further improving the proportion of correctly identified samples. The results of the present study show that the MALDI-TOF MS-based method allows rapid (<20 minutes) bacterial identification directly from positive BCs and with high accuracy. Copyright © 2011 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  5. Machine-learning-based real-bogus system for the HSC-SSP moving object detection pipeline

    NASA Astrophysics Data System (ADS)

    Lin, Hsing-Wen; Chen, Ying-Tung; Wang, Jen-Hung; Wang, Shiang-Yu; Yoshida, Fumi; Ip, Wing-Huen; Miyazaki, Satoshi; Terai, Tsuyoshi

    2018-01-01

    Machine-learning techniques are widely applied in many modern optical sky surveys, e.g., Pan-STARRS1, PTF/iPTF, and the Subaru/Hyper Suprime-Cam survey, to reduce human intervention in data verification. In this study, we have established a machine-learning-based real-bogus system to reject false detections in the Subaru/Hyper-Suprime-Cam Strategic Survey Program (HSC-SSP) source catalog. Therefore, the HSC-SSP moving object detection pipeline can operate more effectively due to the reduction of false positives. To train the real-bogus system, we use stationary sources as the real training set and "flagged" data as the bogus set. The training set contains 47 features, most of which are photometric measurements and shape moments generated from the HSC image reduction pipeline (hscPipe). Our system can reach a true positive rate (tpr) ˜96% with a false positive rate (fpr) ˜1% or tpr ˜99% at fpr ˜5%. Therefore, we conclude that stationary sources are decent real training samples, and using photometry measurements and shape moments can reject false positives effectively.

  6. Activity of a dry mist hydrogen peroxide system against environmental Clostridium difficile contamination in elderly care wards.

    PubMed

    Shapey, S; Machin, K; Levi, K; Boswell, T C

    2008-10-01

    Clostridium difficile causes serious healthcare-associated infections. Infection control is difficult, due in part to environmental contamination with C. difficile spores. These spores are relatively resistant to cleaning and disinfection. The activity of a dry mist hydrogen peroxide decontamination system (Sterinis) against environmental C. difficile contamination was assessed in three elderly care wards. Initial sampling for C. difficile was performed in 16 rooms across a variety of wards and specialties, using Brazier's CCEY (cycloserine-cefoxitin-egg yolk) agar. Ten rooms for elderly patients (eight isolation and two sluice rooms) were then resampled following dry mist hydrogen peroxide decontamination. Representative isolates of C. difficile were typed by polymerase chain reaction ribotyping. C. difficile was recovered from 3%, 11% and 26% of samples from low, medium and high risk rooms, respectively. In 10 high risk elderly care rooms, 24% (48/203) of samples were positive for C. difficile, with a mean of 6.8 colony-forming units (cfu) per 10 samples prior to hydrogen peroxide decontamination. Ribotyping identified the presence of the three main UK epidemic strains (ribotypes 001, 027 and 106) and four rooms contained mixed strains. After a single cycle of hydrogen peroxide decontamination, only 3% (7/203) of samples were positive (P<0.001), with a mean of 0.4 cfu per 10 samples ( approximately 94% reduction). The Sterinis hydrogen peroxide system significantly reduced the extent of environmental contamination with C. difficile in these elderly care rooms. This relatively quick and user-friendly technology might be a more reliable method of terminally disinfecting isolation rooms, following detergent cleaning, compared to the manual application of other disinfectants.

  7. Prospective evaluation of SeptiFast Multiplex PCR in children with systemic inflammatory response syndrome under antibiotic treatment.

    PubMed

    Gies, Franziska; Tschiedel, Eva; Felderhoff-Müser, Ursula; Rath, Peter-Michael; Steinmann, Joerg; Dohna-Schwake, Christian

    2016-08-08

    Antimicrobially pre-treated children with systemic inflammation often pose a diagnostic challenge to the physician. We aimed to evaluate the additional use of SeptiFast multiplex polymerase chain reaction (PCR) to identify causative pathogens in children with suspected systemic bacterial or fungal infection. Prospective observational study in 39 children with systemic inflammatory response syndrome (SIRS) under empiric antibiotic treatment. Primary outcome was the rate of positive blood cultures (BC), compared to the rate of positive SeptiFast (SF) results. In total, 14 SF-samples yielded positive results, compared to 4 positive BC (p < 0.05). All blood cultures and 13 of 14 positive SF-tests were considered infection. Median time for positive BC was 2 days, and time to definite result was 6 days, compared to 12 h for SF. Antimicrobial therapy was adapted in 7 of the 14 patients with positive SeptiFast, and in 3 of the 4 patients with positive BC. Best predictive power for positive SF shown by receiver-operating characteristic was demonstrated for procalcitonin PCT (Area under the curve AUC: 0.79), compared to C-reactive protein CRP (AUC: 0.51) and leukocyte count (AUC: 0.46). A procalcitonin threshold of 0.89 ng/ml yielded a sensitivity of 0.82 and a specifity of 0.7. Children with a positive SeptiFast result on day 0 had a significantly higher risk to require treatment on the Pediatric Intensive Care Unit or to be deceased on day 30 (Odds-Ratio 8.62 (CI 1.44-51.72). The additional testing with SeptiFast in antimicrobially pre-treated children with systemic inflammation enhances the rate of pathogen detection. The influence of multiplex PCR on clinically relevant outcome parameters has to be further evaluated. ( DRKS00004694).

  8. 40 CFR 141.856 - Routine monitoring requirements for subpart H public water systems serving 1,000 or fewer people.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... WATER REGULATIONS Revised Total Coliform Rule § 141.856 Routine monitoring requirements for subpart H... coliform-positive sample taken under the provisions of this section, systems must comply with the repeat... coliform treatment technique triggers specified in § 141.859 have been exceeded. If any trigger has been...

  9. A remote acceptance probe and illumination configuration for spectral assessment of internal attributes of intact fruit

    NASA Astrophysics Data System (ADS)

    Greensill, Colin V.; Walsh, Kerry B.

    2000-12-01

    Near infrared spectroscopy can be employed in the non-invasive assessment of intact fruit for eating quality attributes such as soluble solid content (SSC). Rapid sorting is dependent on a suitable non-contact geometry of fruit, light source and detector assembly, optimized for a given fruit commodity. An optical system was designed with reference to distribution of SSC and light penetration into rockmelon fruit. SSC of mesocarp tissue was not significantly different over the greater part of the proximal-distal axis of the fruit, particularly in the vicinity of the fruit equator. There was also no consistent variation in SSC of mesocarp tissue with respect to radial position of sampling. Mesocarp SSC was higher (~3% w/v) closer to the seed cavity. The optical sampling system was therefore designed to assess an equatorial position on the fruit. Light penetrating a rockmelon fruit was empirically assessed to be diffuse at a depth of <15 mm from the fruit surface. Signal decreased in an exponential proportionality with depth into the fruit, but was still detectable at depths in excess of the seed cavity of rockmelons. A partial transmittance optical design was employed, with a collimated light source interrupted by a central light stop, and a detector viewing the shadowed region of the sample. This system did not physically contact the sample. It was compared to a system with a light excluding `contacting' shroud between the detector and the fruit surface. The performance of calibrations generated using the non-contact configuration was not significantly different than for the configuration requiring contact.

  10. Improved system for floor cleaning in health care facilities.

    PubMed Central

    Schmidt, E A; Coleman, D L; Mallison, G F

    1984-01-01

    A new system has been developed for sanitizing floors in hospitals; this system replaces the traditional procedure of daily dusting and wet mopping with a disinfectant-detergent solution and periodic buffing . This new system relies on a sequence of procedures consisting of dust mopping using a chemically treated dust mop, machine buffing of a sprayed-on polymer treatment, and a second dust mopping . The effectiveness of the procedures was evaluated by means of surface sampling for bacterial contamination and air sampling for airborne bacteria and dust. The level of bacterial contamination on the floors was reduced by 93.6% by using the new system, compared with 79.8% by using the conventional process of dust mopping and wet mopping with a disinfectant solution. The levels of airborne bacteria during and after the individual procedures did not vary significantly from the initial level (123.6 CFU/per m3 of air). A survey of representative colonies from air samples revealed staphylococci, gram-positive bacilli, gram-positive diplococci, yeast cells, and infrequent gram-negative rods. The distribution at the conclusion of the sanitizing process was similar to that at the outset. Similarly, the levels of airborne dust measured during and after the individual procedures did not vary significantly from the initial level. When compared with the traditional method of cleaning by wet mopping , the new method was significantly more effective in removal of microbial contamination and required less labor. PMID:6742835

  11. Development and evaluation of a recombinant-glycoprotein-based latex agglutination test for rabies virus antibody assessment.

    PubMed

    Jemima, Ebenezer Angel; Manoharan, Seeralan; Kumanan, Kathaperumal

    2014-08-01

    The measurement of neutralizing antibodies induced by the glycoprotein of rabies virus is indispensable for assessing the level of neutralizing antibodies in animals or humans. A rapid fluorescent focus inhibition test (RFFIT) has been approved by WHO and is the most widely used method to measure the virus-neutralizing antibody content in serum, but a rapid test system would be of great value to screen large numbers of serum samples. To develop and evaluate a latex agglutination test (LAT) for measuring rabies virus antibodies, a recombinant glycoprotein was expressed in an insect cell system and purified, and the protein was coated onto latex beads at concentrations of 0.1, 0.25, 0.5, 0.75, and 1 mg/ml to find out the optimal concentration for coating latex beads. It was found that 0.5 mg/ml of recombinant protein was optimal for coating latex beads, and this concentration was used to sensitize the latex beads for screening of dog serum samples. Grading of LAT results was done with standard reference serum with known antibody titers. A total of 228 serum samples were tested, out of which 145 samples were positive by both RFFIT and LAT, and the specificity was found to be 100 %. In RFFIT, 151 samples were positive, the sensitivity was found to be 96.03 %, and the accuracy/concordance was found to be 97.39 %. A rapid field test-a latex agglutination test (LAT)-was developed and evaluated for rabies virus antibody assessment using recombinant glycoprotein of rabies virus expressed in an insect cell system.

  12. Integrated ‘omics analysis for studying the microbial community response to a pH perturbation of a cellulose-degrading bioreactor culture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boaro, Amy A.; Kim, Young-Mo; Konopka, Allan E.

    2015-01-05

    Propionate accumulation is a common indicator of process imbalances in anaerobic bioreactor systems. The accumulation of propionate can occur due to low retention rates, hydrogen accumulation, or mechanical changes affecting the proximity between propionate oxidizers and partner species, thereby preventing necessary electron transfer. Few studies, however, have observed the changes in microbial community structure during propionate accumulation. We used 454 pyrosequencing of 16S rDNA to evaluate the community membership during propionate accumulations in replicate bioreactors with rumen based cultures. Half of the culture volume from a parent reactor was transferred to a sterile “daughter” reactor, and both systems were runmore » identically. Both reactors experienced a propionate accumulation after roughly 10 days, with the propionate accumulation being less pronounced in the parent reactor as compared to the daughter reactor. Non-metric multidimensional scaling (NMDS) was used to determine clustering patterns of the samples, and correlative methods were used to determine which OTUs were significantly associated with the movements of samples along the NMDS axes. The presence of Saccharofermentans characterized the position of early samples, whereas the presence of Ruminococcus and Succiniclasticum were more indicative of the positions of later samples. Hydrogen accumulation and low sequence counts indicated low methanogen activity. Although both reactor systems were closed to microbial inputs due to the sterilization of influent media, we recorded significant increases in reactor diversity over time. This suggests that changes in the abundances of dominant community members may affect the sequencing of rare taxa within samples.« less

  13. Survey for Listeria monocytogenes in and on Ready-to-Eat Foods from Retail Establishments in the United States (2010 through 2013): Assessing Potential Changes of Pathogen Prevalence and Levels in a Decade.

    PubMed

    Luchansky, John B; Chen, Yuhuan; Porto-Fett, Anna C S; Pouillot, Régis; Shoyer, Bradley A; Johnson-DeRycke, Rachel; Eblen, Denise R; Hoelzer, Karin; Shaw, William K; van Doren, Jane M; Catlin, Michelle; Lee, Jeehyun; Tikekar, Rohan; Gallagher, Daniel; Lindsay, James A; Dennis, Sherri

    2017-06-01

    A multiyear interagency Listeria monocytogenes Market Basket Survey was undertaken for selected refrigerated ready-to-eat foods purchased at retail in four FoodNet sites in the United States. Food samples from 16 food categories in six broad groups (seafood, produce, dairy, meat, eggs, and combination foods) were collected weekly at large national chain supermarkets and independent grocery stores in California, Maryland, Connecticut, and Georgia for 100 weeks between December 2010 and March 2013. Of the 27,389 total samples, 116 samples tested positive by the BAX PCR system for L. monocytogenes , and the pathogen was isolated and confirmed for 102 samples. Among the 16 food categories, the proportion of positive samples (i.e., without considering clustering effects) based on recovery of a viable isolate of L. monocytogenes ranged from 0.00% (95% confidence interval: 0.00, 0.18) for the category of soft-ripened and semisoft cheese to 1.07% (0.63, 1.68) for raw cut vegetables. Among the 571 samples that tested positive for Listeria-like organisms, the proportion of positive samples ranged from 0.79% (0.45, 1.28) for soft-ripened and semisoft cheese to 4.76% (2.80, 7.51) for fresh crab meat or sushi. Across all 16 categories, L. monocytogenes contamination was significantly associated with the four states (P < 0.05) but not with the packaging location (prepackaged by the manufacturer versus made and/or packaged in the store), the type of store (national chain versus independent), or the season. Among the 102 samples positive for L. monocytogenes , levels ranged from <0.036 most probable number per g to 6.1 log CFU/g. For delicatessen (deli) meats, smoked seafood, seafood salads, soft-ripened and semisoft cheeses, and deli-type salads without meat, the percentage of positive samples was significantly lower (P < 0.001) in this survey than that reported a decade ago based on comparable surveys in the United States. Use of mixed logistic regression models to address clustering effects with regard to the stores revealed that L. monocytogenes prevalence ranged from 0.11% (0.03, 0.34) for sprouts (prepackaged) to 1.01% (0.58, 1.74) for raw cut vegetables (prepackaged).

  14. Ambulatory position and orientation tracking fusing magnetic and inertial sensing.

    PubMed

    Roetenberg, Daniel; Slycke, Per J; Veltink, Peter H

    2007-05-01

    This paper presents the design and testing of a portable magnetic system combined with miniature inertial sensors for ambulatory 6 degrees of freedom (DOF) human motion tracking. The magnetic system consists of three orthogonal coils, the source, fixed to the body and 3-D magnetic sensors, fixed to remote body segments, which measure the fields generated by the source. Based on the measured signals, a processor calculates the relative positions and orientations between source and sensor. Magnetic actuation requires a substantial amount of energy which limits the update rate with a set of batteries. Moreover, the magnetic field can easily be disturbed by ferromagnetic materials or other sources. Inertial sensors can be sampled at high rates, require only little energy and do not suffer from magnetic interferences. However, accelerometers and gyroscopes can only measure changes in position and orientation and suffer from integration drift. By combing measurements from both systems in a complementary Kalman filter structure, an optimal solution for position and orientation estimates is obtained. The magnetic system provides 6 DOF measurements at a relatively low update rate while the inertial sensors track the changes position and orientation in between the magnetic updates. The implemented system is tested against a lab-bound camera tracking system for several functional body movements. The accuracy was about 5 mm for position and 3 degrees for orientation measurements. Errors were higher during movements with high velocities due to relative movement between source and sensor within one cycle of magnetic actuation.

  15. Implementation of a sentinel surveillance system for influenza-like illness (ILI) and severe acute respiratory infection (SARI) in the country of Georgia, 2015-2016.

    PubMed

    Chakhunashvili, Giorgi; Wagner, Abram L; Machablishvili, Ann; Karseladze, Irakli; Tarkhan-Mouravi, Olgha; Zakhashvili, Khatuna; Imnadze, Paata; Boulton, Matthew L

    2017-12-01

    Due to reports of substandard influenza preparedness, the country of Georgia developed two influenza surveillance systems. This paper describes these surveillance systems in their capacity to detect influenza. Two surveillance systems for influenza operate in Georgia: an influenza-like illness (ILI) sentinel surveillance system for out-patient cases, based in the capital, Tbilisi, and a severe acute respiratory infection (SARI) sentinel surveillance system for in-patient cases with five sentinel sites - one in Tbilisi, and four in Kutaisi. Patients in these surveillance systems provide samples for laboratory testing, including influenza confirmation. From 2015-2016, 825 cases were surveilled in the ILI surveillance system and 1367 cases were surveilled in the SARI surveillance system, with 222 (26.9%) and 451 (33.0%) positive for influenza, respectively. Influenza positivity varied by age with adults 30-64 years having highest proportion of influenza-positive cases at 42.2%. The sensitivity of the surveillance systems to influenza was relatively high compared to neighboring countries. These findings show the importance of influenza surveillance in the country of Georgia. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. Factors influencing polymerase chain reaction outcomes in patients with clinically suspected ocular tuberculosis.

    PubMed

    Balne, Praveen Kumar; Modi, Rohit Ramesh; Choudhury, Nuzhat; Mohan, Neha; Barik, Manas Ranjan; Padhi, Tapas Ranjan; Sharma, Savitri; Panigrahi, Satya Ranjan; Basu, Soumyava

    2014-03-25

    Polymerase chain reaction (PCR) assay can be a useful method for definitive diagnosis in paucibacillary infections such as ocular tuberculosis (TB). In this study, we have evaluated factors affecting PCR outcomes in patients with clinically suspected ocular TB. Patients with clinically suspected ocular TB were investigated by PCR of aqueous or vitreous samples. Three control groups were also tested: group 1 included culture-proven non-tuberculous endophthalmitis, group 2 culture-negative non-tuberculous endophthalmitis, and group 3 patients undergoing surgery for uncomplicated cataract. PCR targeted one or more of following targets: IS6110, MPB64, and protein b genes of Mycobacterium tuberculosis complex. Multiple regression analysis (5% level of significance) was done to evaluate the associations between positive PCR outcome and laterality of disease, tuberculin skin test (TST)/interferon-gamma release assay (IGRA), chest radiography, and type of sample (aqueous or vitreous). The main outcome measures were positive PCR by one or more gene targets, and factors influencing positive PCR outcomes. All 114 samples were tested for MPB64, 110 for protein b, and 88 for IS6110. MPB64 was positive in 70.2% (n = 80) of tested samples, protein b in 40.0% (n = 44), and IS6110 in only 9.1% (n = 8). DNA sequencing of amplicons from four randomly chosen PCR reactions showed homology for M. tuberculosis complex. Of the 80 PCR-positive patients, 71 completed a full course of antitubercular therapy, of which 65 patients (91.5%) had complete resolution of inflammation at final follow-up. Among controls, 12.5% (3 out of 24) in group 1 and 18.7% (6 out of 32) in group 2 also tested positive by PCR. No PCR-positive outcome was observed in control group 3 (n = 25). Multiple regression analysis revealed significant association of positive PCR outcome with bilateral presentation, but not with a positive TST/IGRA, chest radiography, or type of sample (aqueous/vitreous) used. Careful selection of gene targets can yield high PCR positivity in clinically suspected ocular TB. Bilateral disease presentation but not any evidence of latent systemic TB influences PCR outcomes. False-positive results may be seen in ocular inflammation unrelated to ocular TB.

  17. A configurable electronics system for the ESS-Bilbao beam position monitors

    NASA Astrophysics Data System (ADS)

    Muguira, L.; Belver, D.; Etxebarria, V.; Varnasseri, S.; Arredondo, I.; del Campo, M.; Echevarria, P.; Garmendia, N.; Feuchtwanger, J.; Jugo, J.; Portilla, J.

    2013-09-01

    A versatile and configurable system has been developed in order to monitorize the beam position and to meet all the requirements of the future ESS-Bilbao Linac. At the same time the design has been conceived to be open and configurable so that it could eventually be used in different kinds of accelerators, independent of the charged particle, with minimal change. The design of the Beam Position Monitors (BPMs) system includes a test bench both for button-type pick-ups (PU) and striplines (SL), the electronic units and the control system. The electronic units consist of two main parts. The first part is an Analog Front-End (AFE) unit where the RF signals are filtered, conditioned and converted to base-band. The second part is a Digital Front-End (DFE) unit which is based on an FPGA board where the base-band signals are sampled in order to calculate the beam position, the amplitude and the phase. To manage the system a Multipurpose Controller (MC) developed at ESSB has been used. It includes the FPGA management, the EPICS integration and Archiver Instances. A description of the system and a comparison between the performance of both PU and SL BPM designs measured with this electronics system are fully described and discussed.

  18. Using dynamic interferometric synthetic aperature radar (InSAR) to image fast-moving surface waves

    DOEpatents

    Vincent, Paul

    2005-06-28

    A new differential technique and system for imaging dynamic (fast moving) surface waves using Dynamic Interferometric Synthetic Aperture Radar (InSAR) is introduced. This differential technique and system can sample the fast-moving surface displacement waves from a plurality of moving platform positions in either a repeat-pass single-antenna or a single-pass mode having a single-antenna dual-phase receiver or having dual physically separate antennas, and reconstruct a plurality of phase differentials from a plurality of platform positions to produce a series of desired interferometric images of the fast moving waves.

  19. Open port sampling interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Berkel, Gary J

    A system for sampling a sample material includes a probe which can have an outer probe housing with an open end. A liquid supply conduit within the housing has an outlet positioned to deliver liquid to the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust conduit within the housing is provided for removing liquid from the open end of the housing. A liquid exhaust system can be provided for removing liquid from themore » liquid exhaust conduit at a second volumetric flow rate, the first volumetric flow rate exceeding the second volumetric flow rate, wherein liquid at the open end will receive sample, liquid containing sample material will be drawn into and through the liquid exhaust conduit, and liquid will overflow from the open end.« less

  20. Evaluation of Automatic Vehicle Location accuracy

    DOT National Transportation Integrated Search

    1999-01-01

    This study assesses the accuracy of the Automatic Vehicle Location (AVL) data provided for the buses of the Ann Arbor Transportation Authority with Global Positioning System (GPS) technology. In a sample of eighty-nine bus trips two kinds of accuracy...

  1. Using Mobile Device Samples to Estimate Traffic Volumes

    DOT National Transportation Integrated Search

    2017-12-01

    In this project, TTI worked with StreetLight Data to evaluate a beta version of its traffic volume estimates derived from global positioning system (GPS)-based mobile devices. TTI evaluated the accuracy of average annual daily traffic (AADT) volume :...

  2. Human virus and microbial indicator occurrence in public-supply groundwater systems: meta-analysis of 12 international studies

    NASA Astrophysics Data System (ADS)

    Fout, G. Shay; Borchardt, Mark A.; Kieke, Burney A.; Karim, Mohammad R.

    2017-06-01

    Groundwater quality is often evaluated using microbial indicators. This study examines data from 12 international groundwater studies (conducted 1992-2013) of 718 public drinking-water systems located in a range of hydrogeological settings. Focus was on testing the value of indicator organisms for identifying virus-contaminated wells. One or more indicators and viruses were present in 37 and 15% of 2,273 samples and 44 and 27% of 746 wells, respectively. Escherichia coli ( E. coli) and somatic coliphage are 7-9 times more likely to be associated with culturable virus-positive samples when the indicator is present versus when it is absent, while F-specific and somatic coliphages are 8-9 times more likely to be associated with culturable virus-positive wells. However, single indicators are only marginally associated with viruses detected by molecular methods, and all microbial indicators have low sensitivity and positive predictive values for virus occurrence, whether by culturable or molecular assays, i.e., indicators are often absent when viruses are present and the indicators have a high false-positive rate. Wells were divided into three susceptibility subsets based on presence of (1) total coliform bacteria or (2) multiple indicators, or (3) location of wells in karst, fractured bedrock, or gravel/cobble settings. Better associations of some indicators with viruses were observed for (1) and (3). Findings indicate the best indicators are E. coli or somatic coliphage, although both indicators may underestimate virus occurrence. Repeat sampling for indicators improves evaluation of the potential for viral contamination in a well.

  3. Production of Monoclonal Antibody Against Excretory-Secretory Antigen of Fasciola hepatica and Evaluation of Its Efficacy in the Diagnosis of Fascioliasis.

    PubMed

    Abdolahi Khabisi, Samaneh; Sarkari, Bahador; Moshfe, Abdolali; Jalali, Sedigheh

    2017-02-01

    Parasitological methods are not helpful for the diagnosis of fascioliasis in acute and invasive periods of the disease. Detection of coproantigens seems to be a suitable alternative approach in the diagnosis of fascioliasis. The present study aimed to develop a reliable antigen detection system, using monoclonal antibodies raised against excretory-secretory (ES) antigen of Fasciola hepatica, for the diagnosis of fascioliasis. Fasciola adult worms were collected from the bile ducts of infected animals. Species of the fluke was determined by polymerase chain reaction-restriction fragment length polymorphism (RFLP-PCR). ES antigen of F. hepatica was prepared. For production of monoclonal antibodies, mice were immunized with ES antigens of F. hepatica. Spleen cells from the immunized mice were fused with NS-1 myeloma cells, using polyethylene glycol. Hybridoma cells secreting specific antibody were expanded and cloned by limiting dilution. Moreover, polyclonal antibody was produced against F. hepatica ES antigen in rabbits. A capture enzyme-linked immunosorbent assay (ELISA) system, using produced monoclonal antibody, was designed and stool samples of infected animals along with control samples were tested by the system. The capture ELISA detected the coproantigen in 27 of 30 (90%) parasitologically confirmed fascioliasis cases, while 4 of 39 (10.25%) samples infected with other parasitic infections showed a positive reaction in this system. No positive reactivity was found with healthy control samples. Accordingly, sensitivity of 90% and specificity of 94.2% were obtained for the capture ELISA system. The results were compared with those obtained with commercial BIO-X ELISA, and a very good (kappa = 0.9) agreement was found between the commercial kit and the developed capture ELISA. Findings of this study showed that the produced monoclonal antibody has appropriate performance for the detection of Fasciola coproantigen in stool samples and can be appropriately used for the diagnosis of fascioliasis.

  4. Auto-calibrated scanning-angle prism-type total internal reflection microscopy for nanometer-precision axial position determination and optional variable-illumination-depth pseudo total internal reflection microscopy

    DOEpatents

    Fang, Ning; Sun, Wei

    2015-04-21

    A method, apparatus, and system for improved VA-TIRFM microscopy. The method comprises automatically controlled calibration of one or more laser sources by precise control of presentation of each laser relative a sample for small incremental changes of incident angle over a range of critical TIR angles. The calibration then allows precise scanning of the sample for any of those calibrated angles for higher and more accurate resolution, and better reconstruction of the scans for super resolution reconstruction of the sample. Optionally the system can be controlled for incident angles of the excitation laser at sub-critical angles for pseudo TIRFM. Optionally both above-critical angle and sub critical angle measurements can be accomplished with the same system.

  5. Microbial and Antibiotic Susceptibility Profile among Clinical Samples of Patients with Acute Leukemia.

    PubMed

    Abdollahi, Alireza; Hakimi, Faezeh; Doomanlou, Mahsa; Azadegan, Azadeh

    2016-04-01

    Preventing and starting early treatment of infections in patients whose immunity system is weak due to malignancies like leukemia can reduce mortality. This study aimed to determine microbial and antibiotic resistance patterns in clinical samples of patients with acute leukemia to start early treatment before the results of clinical tests are known. In this cross-sectional study, the clinical samples of all patients hospitalized with the diagnosis of acute leukemia were cultured and their antibiogram was evaluated. Then, the data were analyzed by SPSS 18 based on the objectives of the study. Of a total of 2,366 samples, 18.95% were reported to be positive blood samples, 22.96% were reported to be urine samples and 36% wound samples. E. coli was the most common bacteria isolated from the blood and urine cultures (34% in blood, 32% in urine culture) while Staphylococcus Aureus was the most common in the wound culture (35%). The highest level of sensitivity in the organisms with positive blood culture was to Ciprofloxacin, while in positive urine and wound culture was to Imipenem. The highest resistance in blood, urine and wound culture was to Cotrimoxazole. According to results obtained from this study, it is necessary to conduct appropriate studies on this issue in specific conditions in our country. The findings of this study can be used in clinics for more accurate diagnosis, more effective treatment before the results of clinical tests are known and also for prevention of infection in cancer patients.

  6. Potential risk of norovirus infection due to the consumption of "ready to eat" food.

    PubMed

    Serracca, Laura; Rossini, Irene; Battistini, Roberta; Goria, Maria; Sant, Serena; De Montis, Gabriella; Ercolini, Carlo

    2012-09-01

    In this study, we investigated the presence of enteric viruses such as norovirus (NoV), hepatitis A virus (HAV), hepatitis E virus (HEV), and adenovirus (HAdV), in vegetables available on the Italian markets. For this aim, 110 national and international "ready to eat" samples were collected and analyzed by biomolecular tests and positive samples were confirmed by sequencing. All samples (100 %) were negative for HAV, HEV, and HAdV, while 13.6 % (15/110) were positive for NoV. Actually there is not a formal surveillance system for NoV infections in Italy but we clearly demonstrated a potential risk associated with the consumption of "ready to eat" vegetables. This study confirmed for the first time in Italy the presence of norovirus in semi-dried tomatoes by PCR technique.

  7. High Resolution Continuous Flow Analysis System for Polar Ice Cores

    NASA Astrophysics Data System (ADS)

    Dallmayr, Remi; Azuma, Kumiko; Yamada, Hironobu; Kjær, Helle Astrid; Vallelonga, Paul; Azuma, Nobuhiko; Takata, Morimasa

    2014-05-01

    In the last decades, Continuous Flow Analysis (CFA) technology for ice core analyses has been developed to reconstruct the past changes of the climate system 1), 2). Compared with traditional analyses of discrete samples, a CFA system offers much faster and higher depth resolution analyses. It also generates a decontaminated sample stream without time-consuming sample processing procedure by using the inner area of an ice-core sample.. The CFA system that we have been developing is currently able to continuously measure stable water isotopes 3) and electrolytic conductivity, as well as to collect discrete samples for the both inner and outer areas with variable depth resolutions. Chemistry analyses4) and methane-gas analysis 5) are planned to be added using the continuous water stream system 5). In order to optimize the resolution of the current system with minimal sample volumes necessary for different analyses, our CFA system typically melts an ice core at 1.6 cm/min. Instead of using a wire position encoder with typical 1mm positioning resolution 6), we decided to use a high-accuracy CCD Laser displacement sensor (LKG-G505, Keyence). At the 1.6 cm/min melt rate, the positioning resolution was increased to 0.27mm. Also, the mixing volume that occurs in our open split debubbler is regulated using its weight. The overflow pumping rate is smoothly PID controlled to maintain the weight as low as possible, while keeping a safety buffer of water to avoid air bubbles downstream. To evaluate the system's depth-resolution, we will present the preliminary data of electrolytic conductivity obtained by melting 12 bags of the North Greenland Eemian Ice Drilling (NEEM) ice core. The samples correspond to different climate intervals (Greenland Stadial 21, 22, Greenland Stadial 5, Greenland Interstadial 5, Greenland Interstadial 7, Greenland Stadial 8). We will present results for the Greenland Stadial -8, whose depths and ages are between 1723.7 and 1724.8 meters, and 35.520 to 35.636 kyr b2k 7), respectively. The results show the conductivity measured upstream and downstream of the debubbler. We will calculate the depth resolution of our system and compare it with earlier studies. 1) Bigler at al, "Optimization of High-Resolution Continuous Flow Analysis For Transient Climate Signals in Ice Cores". Environ. Sci. Technol. 2011, 45, 4483-4489 2) Kaufmann et al, "An Improved Continuous Flow Analysis System for High Resolution Field Measurements on Ice Cores". Environmental Environ. Sci. Technol. 2008, 42, 8044-8050 3) Gkinis, V., T. J. Popp, S. J. Johnsen and T, Blunier, 2010: A continuous stream flash evaporator for the calibration of an IR cavity ring down spectrometer for the isotopic analysis of water. Isotopes in Environmental and Health Studies, 46(4), 463-475. 4) McConnell et al, "Continuous ice-core chemical analyses using inductively coupled plasma mass spectrometry. Environ. Sci. Technol. 2002, 36, 7-11 5) Rhodes et al, "Continuous methane measurements from a late Holocene Greenland ice core : Atmospheric and in-situ signals" Earth and Planetary Science Letters. 2013, 368, 9-19 6) Breton et al, "Quantifying Signal Dispersion in a Hybrid Ice Core Melting System". Environ. Sci. Technol. 2012, 46, 11922-11928 7) Rasmussen et al, " A first chronology for the NEEM ice core". Climate of the Past. 2013, 9, 2967--3013

  8. 40 CFR 141.63 - Maximum contaminant levels (MCLs) for microbiological contaminants.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... repeat sample or E. coli-positive repeat sample, or any total coliform-positive repeat sample following a fecal coliform-positive or E. coli-positive routine sample constitutes a violation of the MCL for total...

  9. 40 CFR 141.63 - Maximum contaminant levels (MCLs) for microbiological contaminants.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... repeat sample or E. coli-positive repeat sample, or any total coliform-positive repeat sample following a fecal coliform-positive or E. coli-positive routine sample constitutes a violation of the MCL for total...

  10. A strategical re-thinking on National Blood Donor Pool: Anti-HBc positivity related re-entry mechanisms.

    PubMed

    Yilmaz, Soner; Unlu, Aytekin; Cetinkaya, Riza Aytac; Yapar, Mehmet; Avci, Ismail Yasar; Yilmaz, Sebahattin; Eyigun, Can Polat

    2016-04-01

    Screening of blood donations for antibodies against hepatitis B core antigen (anti-HBc) is used to prevent transfusion transmitted hepatitis B virus (HBV) infection. In this study, we studied the magnitude of blood donor gain by using a re-entry mechanism in our Blood Bank of Gulhane Military Academy of Medicine. Between January and May 2013, 5148 voluntary blood donors were screened by ELISA method for HBsAg, anti-HBc total and other screening markers, prospectively. Samples with repeated reactivity for the presence of anti-HBc were further tested with four supplemental assays. We detected 515 (10%) anti-HBc positive and 4612 (90%) anti-HBc negative cases in 5127 HBsAg negative serum samples. A total of 461 (89.5%) blood units were reactive for at least one additional serologic parameter and 54 were (10.5%) negative. Isolated anti-HBc positivity rate was 1.3% (69/5127). In the isolated anti-HBc positive samples, 54 were also anti-HBe and HBeAg negative. HBV DNA was not detected in any of the samples. Applying the EDQM criteria would decrease our blood donor loss from 10% to 5.4%. As alternative re-entry mechanisms have already been presented in the literature, institution of a new policy is needed to enhance the limited blood donor pool in our system. Copyright © 2016. Published by Elsevier Ltd.

  11. Rapid identification of bacteria from positive blood culture bottles by use of matrix-assisted laser desorption-ionization time of flight mass spectrometry fingerprinting.

    PubMed

    Christner, Martin; Rohde, Holger; Wolters, Manuel; Sobottka, Ingo; Wegscheider, Karl; Aepfelbacher, Martin

    2010-05-01

    Early and adequate antimicrobial therapy has been shown to improve the clinical outcome in bloodstream infections (BSI). To provide rapid pathogen identification for targeted treatment, we applied matrix-assisted laser desorption-ionization time of flight (MALDI-TOF) mass spectrometry fingerprinting to bacteria directly recovered from blood culture bottles. A total of 304 aerobic and anaerobic blood cultures, reported positive by a Bactec 9240 system, were subjected in parallel to differential centrifugation with subsequent mass spectrometry fingerprinting and reference identification using established microbiological methods. A representative spectrum of bloodstream pathogens was recovered from 277 samples that grew a single bacterial isolate. Species identification by direct mass spectrometry fingerprinting matched reference identification in 95% of these samples and worked equally well for aerobic and anaerobic culture bottles. Application of commonly used score cutoffs to classify the fingerprinting results led to an identification rate of 87%. Mismatching mostly resulted from insufficient bacterial numbers and preferentially occurred with Gram-positive samples. The respective spectra showed low concordance to database references and were effectively rejected by score thresholds. Spiking experiments and examination of the respective study samples even suggested applicability of the method to mixed cultures. With turnaround times around 100 min, the approach allowed for reliable pathogen identification at the day of blood culture positivity, providing treatment-relevant information within the critical phase of septic illness.

  12. Research methods of plasma stream interaction with heat-resistant materials

    NASA Astrophysics Data System (ADS)

    Tyuftyaev, A. S.; Gadzhiev, M. Kh; Sargsyan, M. A.; Chinnov, V. F.; Demirov, N. A.; Kavyrshin, D. I.; Ageev, A. G.; Khromov, M. A.

    2016-11-01

    An experimental automated system was designed and constructed for studying the parameters and characteristics of non-stationary interacting system high-enthalpy-plasma stream-investigated sample: enthalpy of plasma in the incident stream; speed and temperature of plasma stream; temperature of electrons and heavy particles, ionic composition and their spatial distribution; heat flux incident on the sample (kW/cm2); surface temperature of the sample; ablation of the sample material, and others. Measurements of achievable plasma heat flux levels are carried out by calorimetry of plasma streams incident on the surface of multisection copper calorimeter. Determination of acceleration characteristics for profiled plasma torch nozzle, as well as the gas flow rate is produced by measuring the total pressure using the Pitot tube. Video visualization of interacting system is carried out using synchronized high-speed cameras. Micropyrometry of the selected zone on the sample surface is carried out by high-speed, three-wavelength pyrometer. To measure the rate of mass loss of the sample, in addition to the weighing method of evaluation the methods of laser knife and two-position stereoscopy are used. Plasma and sample emission characteristics are performed with two separate spectrometers.

  13. Digital redesign of the control system for the Robotics Research Corporation model K-1607 robot

    NASA Technical Reports Server (NTRS)

    Carroll, Robert L.

    1989-01-01

    The analog control system for positioning each link of the Robotics Research Corporation Model K-1607 robot manipulator was redesigned for computer control. In order to accomplish the redesign, a linearized model of the dynamic behavior of the robot was developed. The parameters of the model were determined by examination of the input-output data collected in closed-loop operation of the analog control system. The robot manipulator possesses seven degrees of freedom in its motion. The analog control system installed by the manufacturer of the robot attempts to control the positioning of each link without feedback from other links. Constraints on the design of a digital control system include: the robot cannot be disassembled for measurement of parameters; the digital control system must not include filtering operations if possible, because of lack of computer capability; and criteria of goodness of control system performing is lacking. The resulting design employs sampled-data position and velocity feedback. The criteria of the design permits the control system gain margin and phase margin, measured at the same frequencies, to be the same as that provided by the analog control system.

  14. Sputum induction is a safe procedure to use in prisoners and MGIT is the best culture method to diagnose tuberculosis in prisons: a cohort study.

    PubMed

    Rueda, Zulma Vanessa; López, Lucelly; Marín, Diana; Vélez, Lázaro A; Arbeláez, María Patricia

    2015-04-01

    To evaluate the concordance and safety of induced sputum (IS) and spontaneous sputum (SS), and estimate concordance and time to detection of M. tuberculosis between Lowenstein-Jensen (LJ), thin-layer agar (TLA), and the Mycobacteria Growth Indicator Tube system (MGIT). This was a cohort study. Prisoners with pulmonary tuberculosis (PTB) were followed for 2 years. At baseline and every follow-up visit, three sputum samples were taken on consecutive days (one IS and two SS) and adverse events occurring before, during, and 30 min after IS were registered. All sputum samples were stained with auramine and cultured in LJ, TLA (to test resistance), and MGIT. Five hundred eighty-six IS and 532 SS were performed on 64 PTB patients. Breathlessness (1.6%), cough (1.2%), hemoptysis (0.3%), and cyanosis (0.2%) were the only complications. Concordance between IS and SS was 0.78 (95% confidence interval 0.69-0.87); 11 positive cultures from IS samples were negative in SS, and 11 positive cultures from SS samples were negative in IS. One hundred seventy-eight cultures were positive by any technique: MGIT 95%, LJ 73%, and TLA 57%. Time to detection of M. tuberculosis in LJ, TLA, and MGIT was 31, 18, and 11 days, respectively. The IS procedure is safe in prisons. The MGIT system is better and faster than LJ and TLA in the diagnosis of M. tuberculosis. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Replicating the positivity effect in picture memory in Koreans: evidence for cross-cultural generalizability.

    PubMed

    Kwon, Yookyung; Scheibe, Susanne; Samanez-Larkin, Gregory R; Tsai, Jeanne L; Carstensen, Laura L

    2009-09-01

    Older adults' relatively better memory for positive over negative material (positivity effect) has been widely observed in Western samples. This study examined whether a relative preference for positive over negative material is also observed in older Koreans. Younger and older Korean participants viewed images from the International Affective Picture System (IAPS), were tested for recall and recognition of the images, and rated the images for valence. Cultural differences in the valence ratings of images emerged. Once considered, the relative preference for positive over negative material in memory observed in older Koreans was indistinguishable from that observed previously in older Americans. (c) 2009 APA, all rights reserved.

  16. Measuring the executive regulation of emotion with self-rating scales in a nonclinical population.

    PubMed

    Spinella, Marcello

    2007-01-01

    Prefrontal systems play an important role in the regulation of emotion as evidenced by clinical neuroimaging studies. Both subjective and objective neuropsychological tests provide functional evidence of executive dysfunction in emotional deregulation. The present authors evaluated these relationships here in a nonclinical community sample using the Frontal Systems Behavior Scale, Profile of Mood States (POMS), and Depression Anxiety Stress Scales (DASS). Positive correlations uniformly emerged between prefrontal system dysfunction and negative emotional states (anger, depression, anxiety, stress, confusion, and fatigue), whereas positive emotion (vigor) showed a modest inverse correlation with prefrontal system dysfunction, even after control for demographic influences. These relationships may result from cognitive strategies for managing emotion mediated by reciprocal connections between prefrontal systems and the limbic system. The findings corroborated those of other methodologies, supporting the Frontal Systems Behavior Scale (FrSBe) as a valid tool to measure prefrontal function in nonclinical populations.

  17. Autonomous GN and C for Spacecraft Exploration of Comets and Asteroids

    NASA Technical Reports Server (NTRS)

    Carson, John M.; Mastrodemos, Nickolaos; Myers, David M.; Acikmese, Behcet; Blackmore, James C.; Moussalis, Dhemetrio; Riedel, Joseph E.; Nolet, Simon; Chang, Johnny T.; Mandic, Milan; hide

    2010-01-01

    A spacecraft guidance, navigation, and control (GN&C) system is needed to enable a spacecraft to descend to a surface, take a sample using a touch-and-go (TAG) sampling approach, and then safely ascend. At the time of this reporting, a flyable GN&C system that can accomplish these goals is beyond state of the art. This article describes AutoGNC, which is a GN&C system capable of addressing these goals, which has recently been developed and demonstrated to a maturity TRL-5-plus. The AutoGNC solution matures and integrates two previously existing JPL capabilities into a single unified GN&C system. The two capabilities are AutoNAV and GREX. AutoNAV is JPL s current flight navigation system, and is fairly mature with respect to flybys and rendezvous with small bodies, but is lacking capability for close surface proximity operations, sampling, and contact. G-REX is a suite of low-TRL algorithms and capabilities that enables spacecraft operations in close surface proximity and for performing sampling/contact. The development and integration of AutoNAV and G-REX components into AutoGNC provides a single, unified GN&C capability for addressing the autonomy, close-proximity, and sampling/contact aspects of small-body sample return missions. AutoGNC is an integrated capability comprising elements that were developed separately. The main algorithms and component capabilities that have been matured and integrated are autonomy for near-surface operations, terrain-relative navigation (TRN), real-time image-based feedback guidance and control, and six degrees of freedom (6DOF) control of the TAG sampling event. Autonomy is achieved based on an AutoGNC Executive written in Virtual Machine Language (VML) incorporating high-level control, data management, and fault protection. In descending to the surface, the AutoGNC system uses camera images to determine its position and velocity relative to the terrain. This capability for TRN leverages native capabilities of the original AutoNAV system, but required advancements that integrate the separate capabilities for shape modeling, state estimation, image rendering, defining a database of onboard maps, and performing real-time landmark recognition against the stored maps. The ability to use images to guide the spacecraft requires the capability for image-based feedback control. In Auto- GNC, navigation estimates are fed into an onboard guidance and control system that keeps the spacecraft guided along a desired path, as it descends towards its targeted landing or sampling site. Once near the site, AutoGNC achieves a prescribed guidance condition for TAG sampling (position/orientation, velocity), and a prescribed force profile on the sampling end-effector. A dedicated 6DOF TAG control then implements the ascent burn while recovering from sampling disturbances and induced attitude rates. The control also minimizes structural interactions with flexible solar panels and disallows any part of the spacecraft from making contact with the ground (other than the intended end-effector).

  18. Daily social interactions, close relationships, and systemic inflammation in two samples: Healthy middle-aged and older adults.

    PubMed

    Bajaj, Amoha; John-Henderson, Neha A; Cundiff, Jenny M; Marsland, Anna L; Manuck, Stephen B; Kamarck, Thomas W

    2016-11-01

    Systemic inflammation is thought to be a biological mediator between social relationship quality and premature mortality. Empirical work has yielded mixed support for an association of social relationship variables with systemic inflammation, perhaps due to methodological limitations. To date, research in this literature has focused on global perceptions of social relationships, with limited attention to the covariance of characteristics of daily social interactions with inflammation. Here, we examine whether daily interactions, as assessed by ecological momentary assessment (EMA), associate with peripheral markers of inflammation among midlife and older adults. Global social support and integration were measured using the Interpersonal Support Evaluation List (ISEL) and the Social Network Index (SNI), respectively, in older adults from the Pittsburgh Healthy Heart Project (PHHP), and in middle-aged adults from the Adult Health and Behavior Project-II (AHAB-II). Using time-sampled EMA, we assessed the proportion of the day spent in positive and negative social interactions. Systemic markers of inflammation were interleukin (IL)-6 and C-reactive protein (CRP). Global measures of support and integration did not associate with inflammation in either sample. In older adults, relative frequency of total positive interactions, those with close others (i.e. spouse, friends, family), and those with coworkers predicted lower concentrations of IL-6 in fully adjusted models, accounting for age, sex, race, education, BMI, smoking and alcohol. In middle-aged adults, relative frequency of positive interactions with close others was also inversely associated with IL-6 level and relative frequency of negative marital interactions was unexpectedly inversely associated with CRP level. Characteristics of daily social interactions among midlife and older adults associate with markers of systemic inflammation that are known to predict risk for cardiovascular disease. Ambulatory measures may better capture health-relevant social processes in daily life than retrospective, global self-report measures. Published by Elsevier Inc.

  19. Extended Task Space Control for Robotic Manipulators

    NASA Technical Reports Server (NTRS)

    Backes, Paul G. (Inventor); Long, Mark K. (Inventor)

    1996-01-01

    The invention is a method of operating a robot in successive sampling intervals to perform a task, the robot having joints and joint actuators with actuator control loops, by decomposing the task into behavior forces, accelerations, velocities and positions of plural behaviors to be exhibited by the robot simultaneously, computing actuator accelerations of the joint actuators for the current sampling interval from both behavior forces, accelerations velocities and positions of the current sampling interval and actuator velocities and positions of the previous sampling interval, computing actuator velocities and positions of the joint actuators for the current sampling interval from the actuator velocities and positions of the previous sampling interval, and, finally, controlling the actuators in accordance with the actuator accelerations, velocities and positions of the current sampling interval. The actuator accelerations, velocities and positions of the current sampling interval are stored for use during the next sampling interval.

  20. Array-based photoacoustic spectroscopy

    DOEpatents

    Autrey, S. Thomas; Posakony, Gerald J.; Chen, Yu

    2005-03-22

    Methods and apparatus for simultaneous or sequential, rapid analysis of multiple samples by photoacoustic spectroscopy are disclosed. A photoacoustic spectroscopy sample array including a body having at least three recesses or affinity masses connected thereto is used in conjunction with a photoacoustic spectroscopy system. At least one acoustic detector is positioned near the recesses or affinity masses for detection of acoustic waves emitted from species of interest within the recesses or affinity masses.

  1. High density grids

    DOEpatents

    Cohen, Aina E.; Baxter, Elizabeth L.

    2018-01-16

    An X-ray data collection grid device is provided that includes a magnetic base that is compatible with robotic sample mounting systems used at synchrotron beamlines, a grid element fixedly attached to the magnetic base, where the grid element includes at least one sealable sample window disposed through a planar synchrotron-compatible material, where the planar synchrotron-compatible material includes at least one automated X-ray positioning and fluid handling robot fiducial mark.

  2. Frequency position modulation using multi-spectral projections

    NASA Astrophysics Data System (ADS)

    Goodman, Joel; Bertoncini, Crystal; Moore, Michael; Nousain, Bryan; Cowart, Gregory

    2012-10-01

    In this paper we present an approach to harness multi-spectral projections (MSPs) to carefully shape and locate tones in the spectrum, enabling a new and robust modulation in which a signal's discrete frequency support is used to represent symbols. This method, called Frequency Position Modulation (FPM), is an innovative extension to MT-FSK and OFDM and can be non-uniformly spread over many GHz of instantaneous bandwidth (IBW), resulting in a communications system that is difficult to intercept and jam. The FPM symbols are recovered using adaptive projections that in part employ an analog polynomial nonlinearity paired with an analog-to-digital converter (ADC) sampling at a rate at that is only a fraction of the IBW of the signal. MSPs also facilitate using commercial of-the-shelf (COTS) ADCs with uniform-sampling, standing in sharp contrast to random linear projections by random sampling, which requires a full Nyquist rate sample-and-hold. Our novel communication system concept provides an order of magnitude improvement in processing gain over conventional LPI/LPD communications (e.g., FH- or DS-CDMA) and facilitates the ability to operate in interference laden environments where conventional compressed sensing receivers would fail. We quantitatively analyze the bit error rate (BER) and processing gain (PG) for a maximum likelihood based FPM demodulator and demonstrate its performance in interference laden conditions.

  3. Study on the position accuracy of a mechanical alignment system

    NASA Astrophysics Data System (ADS)

    Cai, Yimin

    In this thesis, we investigated the precision level and established the baseline achieved by a mechanical alignment system using datums and reference surfaces. The factors which affect the accuracy of mechanical alignment system were studied and methodology was developed to suppress these factors so as to reach its full potential precision. In order to characterize the mechanical alignment system quantitatively, a new optical position monitoring system by using quadrant detectors has been developed in this thesis, it can monitor multi-dimensional degrees of mechanical workpieces in real time with high precision. We studied the noise factors inside the system and optimized the optical system. Based on the fact that one of the major limiting noise factors is the shifting of the laser beam, a noise cancellation technique has been developed successfully to suppress this noise, the feasibility of an ultra high resolution (<20 A) for displacement monitoring has been demonstrated. Using the optical position monitoring system, repeatability experiment of the mechanical alignment system has been conducted on different kinds of samples including steel, aluminum, glass and plastics with the same size 100mm x 130mm. The alignment accuracy was studied quantitatively rather than qualitatively before. In a controlled environment, the alignment precision can be improved 5 folds by securing the datum without other means of help. The alignment accuracy of an aluminum workpiece having reference surface by milling is about 3 times better than by shearing. Also we have found that sample material can have fairly significant effect on the alignment precision of the system. Contamination trapped between the datum and reference surfaces in mechanical alignment system can cause errors of registration or reduce the level of manufacturing precision. In the thesis, artificial and natural dust particles were used to simulate the real situations and their effects on system precision have been investigated. In this experiment, we discovered two effective cleaning processes.

  4. Salmonella in beef and produce from honduras.

    PubMed

    Maradiaga, Martha; Miller, Mark F; Thompson, Leslie; Pond, Ansen; Gragg, Sara E; Echeverry, Alejandro; Garcia, Lyda G; Loneragan, Guy H; Brashears, Mindy M

    2015-03-01

    Salmonella continues to cause a considerable number of foodborne illnesses worldwide. The sources of outbreaks include contaminated meat and produce. The purpose of this study was to establish an initial investigation of the burden of Salmonella in produce and beef from Honduras by sampling retail markets and abattoirs. Retail produce samples (cantaloupes, cilantro, cucumbers, leafy greens, peppers, and tomatoes; n = 573) were purchased in three major cities of Honduras, and retail whole-muscle beef (n = 555) samples were also purchased in four major cities. Additionally, both hide and beef carcass (n = 141) samples were collected from two Honduran abattoirs. Whole-muscle beef samples were obtained using a sponge hydrated with buffered peptone water, and 10 ml of the buffered peptone water rinsate of each produce sample was collected with a dry sponge and placed in a bag to be transported back to the United States. Salmonella was detected using a commercially available, closeplatform PCR system, and positive samples were subjected to culture on selective media to obtain isolates. Overall, the prevalence of Salmonella-positive samples, based on PCR detection in Honduras (n = 555) retail beef was 10.1% (95% confidence interval = 7.8, 12.9), whereas 7.8% (n = 141) of beef carcass and hides samples were positive in both beef plants. The overall Salmonella prevalence for all produce samples (n = 573) collected was 2.1% (95% confidence interval = 1.2, 3.6). The most common serotypes identified in Honduras were Salmonella Typhimurium followed by Derby. These results provide an indication of Salmonella contamination of beef and produce in Honduras. Developing a Salmonella baseline for Latin America through an initial investigation like the one presented here contributes to a broader global understanding of the potential exposure through food, thus providing insight into the needs for control strategies.

  5. What is Next? Linking all Samples of Planet Earth.

    NASA Astrophysics Data System (ADS)

    Wyborn, L. A.; Lehnert, K.; Klump, J. F.; Arko, R. A.; Cox, S. J. D.; Devaraju, A.; Elger, K.; Murphy, F.; Fleischer, D.

    2016-12-01

    The process of sampling, observing and analyzing physical samples is not unique to the geosciences. Physical sampling (taking specimens) is a fundamental strategy in many natural sciences, typically to support ex-situ observations in laboratories with the goal of characterizing real-world entities or populations. Observations and measurements are made on individual specimens and their derived samples in various ways, with results reported in research publications. Research on an individual sample is often published in numerous articles, based on multiple, potentially unrelated research programs conducted over many years. Even high-volume Earth observation datasets are proxies of real world phenomena and require calibration by measurements made on position located, well described physical samples. Unique, persistent web-compatible identifiers for physical objects and related sampling features are required to ensure their unambiguous citation and connection to related datasets through web identifiers. Identifier systems have been established within specific domains (e.g., bio, geo, hydro) or different sectors (e.g., museums, government agencies, universities), including the International Geo Sample Number (IGSN) in the geosciences, which has been used for rock, fossil, mineral, soil, regolith, fluid, plant and synthetic materials. IGSNs are issued through a governance system that ensures they are globally unique. Each IGSN directs to a digital representation of the physical object via the Handle.net global resolver system, the same system used for resolving DOI. To enable the unique identification of all samples on Planet Earth and of data derived from them, the next step is to ensure IGSNs can either be integrated with comparable identifier systems in other domains/sectors, or introduced into domains that do not have a viable system. A registry of persistent identifier systems for physical samples would allow users to choose which system best suits their needs. Such a registry may also facilitate unifying best practice in these multiple systems to enable consistent referencing of physical samples and of methods used to link digital data to its sources. IGSNs could be extended into other domains, but additional methodologies of sample collection, curation and processing may need to be considered.

  6. Isotachophoresis system having larger-diameter channels flowing into channels with reduced diameter and with selectable counter-flow

    DOEpatents

    Mariella, Jr., Raymond P.

    2018-03-06

    An isotachophoresis system for separating a sample containing particles into discrete packets including a flow channel, the flow channel having a large diameter section and a small diameter section; a negative electrode operably connected to the flow channel; a positive electrode operably connected to the flow channel; a leading carrier fluid in the flow channel; a trailing carrier fluid in the flow channel; and a control for separating the particles in the sample into discrete packets using the leading carrier fluid, the trailing carrier fluid, the large diameter section, and the small diameter section.

  7. Work Measurement as a Generalized Quantum Measurement

    NASA Astrophysics Data System (ADS)

    Roncaglia, Augusto J.; Cerisola, Federico; Paz, Juan Pablo

    2014-12-01

    We present a new method to measure the work w performed on a driven quantum system and to sample its probability distribution P (w ). The method is based on a simple fact that remained unnoticed until now: Work on a quantum system can be measured by performing a generalized quantum measurement at a single time. Such measurement, which technically speaking is denoted as a positive operator valued measure reduces to an ordinary projective measurement on an enlarged system. This observation not only demystifies work measurement but also suggests a new quantum algorithm to efficiently sample the distribution P (w ). This can be used, in combination with fluctuation theorems, to estimate free energies of quantum states on a quantum computer.

  8. Nontuberculous Mycobacteria, Fungi, and Opportunistic Pathogens in Unchlorinated Drinking Water in the Netherlands

    PubMed Central

    van der Kooij, Dick

    2013-01-01

    The multiplication of opportunistic pathogens in drinking water supplies might pose a threat to public health. In this study, distributed unchlorinated drinking water from eight treatment plants in the Netherlands was sampled and analyzed for fungi, nontuberculous mycobacteria (NTM), and several opportunistic pathogens by using selective quantitative PCR methods. Fungi and NTM were detected in all drinking water samples, whereas Legionella pneumophila, Pseudomonas aeruginosa, Stenotrophomonas maltophilia, and Aspergillus fumigatus were sporadically observed. Mycobacterium avium complex and Acanthamoeba spp. were not detected. Season had no influence on the occurrence of these organisms, except for NTM and S. maltophilia, which were present in higher numbers in the summer. Opportunistic pathogens were more often observed in premise plumbing water samples than in samples from the distribution system. The lowest number of these organisms was observed in the finished water at the plant. Thus, fungi, NTM, and some of the studied opportunistic pathogens can multiply in the distribution and premise plumbing systems. Assimilable organic carbon (AOC) and/or total organic carbon (TOC) had no clear effects on fungal and NTM numbers or on P. aeruginosa- and S. maltophilia-positive samples. However, L. pneumophila was detected more often in water with AOC concentrations above 10 μg C liter−1 than in water with AOC levels below 5 μg C liter−1. Finally, samples that contained L. pneumophila, P. aeruginosa, or S. maltophilia were more frequently positive for a second opportunistic pathogen, which shows that certain drinking water types and/or sampling locations promote the growth of multiple opportunistic pathogens. PMID:23160134

  9. Nontuberculous mycobacteria, fungi, and opportunistic pathogens in unchlorinated drinking water in The Netherlands.

    PubMed

    van der Wielen, Paul W J J; van der Kooij, Dick

    2013-02-01

    The multiplication of opportunistic pathogens in drinking water supplies might pose a threat to public health. In this study, distributed unchlorinated drinking water from eight treatment plants in the Netherlands was sampled and analyzed for fungi, nontuberculous mycobacteria (NTM), and several opportunistic pathogens by using selective quantitative PCR methods. Fungi and NTM were detected in all drinking water samples, whereas Legionella pneumophila, Pseudomonas aeruginosa, Stenotrophomonas maltophilia, and Aspergillus fumigatus were sporadically observed. Mycobacterium avium complex and Acanthamoeba spp. were not detected. Season had no influence on the occurrence of these organisms, except for NTM and S. maltophilia, which were present in higher numbers in the summer. Opportunistic pathogens were more often observed in premise plumbing water samples than in samples from the distribution system. The lowest number of these organisms was observed in the finished water at the plant. Thus, fungi, NTM, and some of the studied opportunistic pathogens can multiply in the distribution and premise plumbing systems. Assimilable organic carbon (AOC) and/or total organic carbon (TOC) had no clear effects on fungal and NTM numbers or on P. aeruginosa- and S. maltophilia-positive samples. However, L. pneumophila was detected more often in water with AOC concentrations above 10 μg C liter(-1) than in water with AOC levels below 5 μg C liter(-1). Finally, samples that contained L. pneumophila, P. aeruginosa, or S. maltophilia were more frequently positive for a second opportunistic pathogen, which shows that certain drinking water types and/or sampling locations promote the growth of multiple opportunistic pathogens.

  10. X-ray transport and radiation response assessment (XTRRA) experiments at the National Ignition Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fournier, K. B., E-mail: fournier2@llnl.gov; Brown, C. G.; Yeoman, M. F.

    2016-11-15

    Our team has developed an experimental platform to evaluate the x-ray-generated stress and impulse in materials. Experimental activities include x-ray source development, design of the sample mounting hardware and sensors interfaced to the National Ignition Facility’s diagnostics insertion system, and system integration into the facility. This paper focuses on the X-ray Transport and Radiation Response Assessment (XTRRA) test cassettes built for these experiments. The test cassette is designed to position six samples at three predetermined distances from the source, each known to within ±1% accuracy. Built-in calorimeters give in situ measurements of the x-ray environment along the sample lines ofmore » sight. The measured accuracy of sample responses as well as planned modifications to the XTRRA cassette is discussed.« less

  11. X-ray transport and radiation response assessment (XTRRA) experiments at the National Ignition Facility

    DOE PAGES

    Fournier, K. B.; Brown, Jr., C. G.; Yeoman, M. F.; ...

    2016-08-10

    Our team has developed an experimental platform to evaluate the x-ray-generated stress and impulse in materials. Experimental activities include x-ray source development, design of the sample mounting hardware and sensors interfaced to the NIF’s diagnostics insertion system, and system integration into the facility. This paper focuses on the X-ray Transport and Radiation Response Assessment (XTRRA) test cassettes built for these experiments. The test cassette is designed to position six samples at three predetermined distances from the source, each known to within ±1% accuracy. Built in calorimeters give in situ measurements of the x-ray environment along the sample lines of sight.more » We discuss the measured accuracy of sample responses, as well as planned modifications to the XTRRA cassette.« less

  12. Evaluation of the LIA-ANA-Profile-17S for the detection of autoantibodies to nuclear antigens.

    PubMed

    Yi, Ahram; Lee, Chang-Hoon; Moon, Hee-Won; Kim, Hanah; Hur, Mina; Yun, Yeo-Min

    2018-05-01

    The diagnostic tests for autoimmune disease include screening for autoantibodies for nuclear antigens (ANA) and antibodies against extractable nuclear antigens (ENA). Using the line immunoassay (LIA) method, various kinds of ENA antibodies can be detected simultaneously. We evaluated the performance of the newly launched LIA-ANA-Profile-17S (Shenzhen YHLO Biotech, Shenzhen, China) as compared to a conventional LIA kit. Residual samples were collected from 200 patients who had been tested for ANA using indirect immunofluorescence. The LIA-ANA-Profile-17S was compared to the EuroLine ANA (Euroimmun, Oberlausitz, Germany) for the analysis of 17 different autoantibodies. The concordance rate and agreement between assays were determined. Samples showing discrepancies between the LIA-ANA-Profile-17S and EuroLine tests were further examined through additional analysis. The overall agreement was moderate (kappa = 0.759, 95% CI = 0.712-0.805). Agreement between assays ranged from weak to almost perfect, except for those tests targeting nucleosomes, histones, and PM-Scl. Of the 57 disparate results between LIA-ANA-Profile-17S and EuroLine, 38 (66.7%) samples tested positive under an additional assay, showing variable patterns between types of autoantibodies. The positive rate of each autoantibody between LIA-ANA-Profile-17S and EuroLine did not differ significantly, except for anti-nucleosome and anti-histone assays in samples from patients diagnosed with systemic lupus erythematosus (P = 0.004 and 0.001, respectively). Compared to those from the conventional EuroLine assay, the LIA-ANA-Profile-17S results showed variable agreement in samples showing different prevalence of each autoantibody. The most frequently detected antibodies showed almost perfect agreement. The LIA-ANA-Profile-17S could play a role in the diagnosis of systemic autoimmune disease in ANA-positive samples. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Field Detection of Drugs of Abuse in Oral Fluid Using the Alere™ DDS®2 Mobile Test System with Confirmation by Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS).

    PubMed

    Krotulski, Alex J; Mohr, Amanda L A; Friscia, Melissa; Logan, Barry K

    2018-04-01

    The collection and analysis of drugs in oral fluid (OF) at the roadside has become more feasible with the introduction of portable testing devices such as the Alere™ DDS®2 Mobile Test System (DDS®2). The objective of this study was to compare the on-site results for the DDS®2 to laboratory-based confirmatory assays with respect to detection of drugs of abuse in human subjects. As part of a larger Institutional Review Board approved study, two OF samples were collected from each participant at a music festival in Miami, FL, USA. One OF sample was field screened using the DDS®2, and a confirmatory OF sample was collected using the Quantisal™ OF collection device and submitted to the laboratory for testing. In total, 124 subjects participated in this study providing two contemporaneous OF samples. DDS®2 field screening yielded positive results for delta-9-tetrahydrocannabinol (THC) (n = 27), cocaine (n = 12), amphetamine (n = 3), methamphetamine (n = 3) and benzodiazepine (n = 1). No opiate-positive OF samples were detected. For cocaine, amphetamine, methamphetamine and benzodiazepines, the DDS®2 displayed sensitivity, specificity and accuracy of 100%. For THC, the DDS®2 displayed sensitivity of 90%, specificity of 100% and accuracy of 97.5%, when the threshold for confirmation matched that of the manufacturers advertised cut-off. When this confirmatory threshold was lowered to the analytical limit of detection (i.e., 1 ng/mL), apparent device performance for THC was poorer due to additional samples testing positive by confirmatory assay that had tested negative on the DDS®2, demonstrating a need for correlation between manufacturer cut-off and analytical reporting limit. These results from drug-using subjects demonstrate the value of field-based OF testing, and illustrate the significance of selecting an appropriate confirmation cut-off concentration with respect to performance evaluation and detection of drug use.

  14. Automatic detection of lameness in gestating group-housed sows using positioning and acceleration measurements.

    PubMed

    Traulsen, I; Breitenberger, S; Auer, W; Stamer, E; Müller, K; Krieter, J

    2016-06-01

    Lameness is an important issue in group-housed sows. Automatic detection systems are a beneficial diagnostic tool to support management. The aim of the present study was to evaluate data of a positioning system including acceleration measurements to detect lameness in group-housed sows. Data were acquired at the Futterkamp research farm from May 2012 until April 2013. In the gestation unit, 212 group-housed sows were equipped with an ear sensor to sample position and acceleration per sow and second. Three activity indices were calculated per sow and day: path length walked by a sow during the day (Path), number of squares (25×25 cm) visited during the day (Square) and variance of the acceleration measurement during the day (Acc). In addition, data on lameness treatments of the sows and a weekly lameness score were used as reference systems. To determine the influence of a lameness event, all indices were analysed in a linear random regression model. Test day, parity class and day before treatment had a significant influence on all activity indices (P<0.05). In healthy sows, indices Path and Square increased with increasing parity, whereas variance slightly decreased. The indices Path and Square showed a decreasing trend in a 14-day period before a lameness treatment and to a smaller extent before a lameness score of 2 (severe lameness). For the index acceleration, there was no obvious difference between the lame and non-lame periods. In conclusion, positioning and acceleration measurements with ear sensors can be used to describe the activity pattern of sows. However, improvements in sampling rate and analysis techniques should be made for a practical application as an automatic lameness detection system.

  15. Real-time catheter tracking for high-dose-rate prostate brachytherapy using an electromagnetic 3D-guidance device: A preliminary performance study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou Jun; Sebastian, Evelyn; Mangona, Victor

    2013-02-15

    Purpose: In order to increase the accuracy and speed of catheter reconstruction in a high-dose-rate (HDR) prostate implant procedure, an automatic tracking system has been developed using an electromagnetic (EM) device (trakSTAR, Ascension Technology, VT). The performance of the system, including the accuracy and noise level with various tracking parameters and conditions, were investigated. Methods: A direct current (dc) EM transmitter (midrange model) and a sensor with diameter of 1.3 mm (Model 130) were used in the trakSTAR system for tracking catheter position during HDR prostate brachytherapy. Localization accuracy was assessed under both static and dynamic analyses conditions. For themore » static analysis, a calibration phantom was used to investigate error dependency on operating room (OR) table height (bottom vs midposition vs top), sensor position (distal tip of catheter vs connector end of catheter), direction [left-right (LR) vs anterior-posterior (AP) vs superior-inferior (SI)], sampling frequency (40 vs 80 vs 120 Hz), and interference from OR equipment (present vs absent). The mean and standard deviation of the localization offset in each direction and the corresponding error vectors were calculated. For dynamic analysis, the paths of five straight catheters were tracked to study the effects of directions, sampling frequency, and interference of EM field. Statistical analysis was conducted to compare the results in different configurations. Results: When interference was present in the static analysis, the error vectors were significantly higher at the top table position (3.3 {+-} 1.3 vs 1.8 {+-} 0.9 mm at bottom and 1.7 {+-} 1.0 mm at middle, p < 0.001), at catheter end position (3.1 {+-} 1.1 vs 1.4 {+-} 0.7 mm at the tip position, p < 0.001), and at 40 Hz sampling frequency (2.6 {+-} 1.1 vs 2.4 {+-} 1.5 mm at 80 Hz and 1.8 {+-} 1.1 at 160 Hz, p < 0.001). So did the mean offset errors in the LR direction (-1.7 {+-} 1.4 vs 0.4 {+-} 0.5 mm in AP and 0.8 {+-} 0.8 mm in SI directions, p < 0.001). The error vectors were significantly higher with surrounding interference (2.2 {+-} 1.3 mm) vs without interference (1.0 {+-} 0.7 mm, p < 0.001). An accuracy of 1.6 {+-} 0.2 mm can be reached when using optimum configuration (160 Hz at middle table position). When interference was present in the dynamic tracking, the mean tracking errors in LR direction (1.4 {+-} 0.5 mm) was significantly higher than that in AP direction (0.3 {+-} 0.2 mm, p < 0.001). So did the mean vector errors at 40 Hz (2.1 {+-} 0.2 mm vs 1.3 {+-} 0.2 mm at 80 Hz and 0.9 {+-} 0.2 mm at 160 Hz, p < 0.05). However, when interference was absent, they were comparable in the both directions and at all sampling frequencies. An accuracy of 0.9 {+-} 0.2 mm was obtained for the dynamic tracking when using optimum configuration. Conclusions: The performance of an EM tracking system depends highly on the system configuration and surrounding environment. The accuracy of EM tracking for catheter reconstruction in a prostate HDR brachytherapy procedure can be improved by reducing interference from surrounding equipment, decreasing distance from transmitter to tracking area, and choosing appropriated sampling frequency. A calibration scheme is needed to further reduce the tracking error when the interference is high.« less

  16. State-of-the-art technologies of forest inventory and monitoring in Taiwan

    Treesearch

    Fong-Long Feng

    2000-01-01

    Ground surveys, remote sensing (RS), global positioning systems (GPS), geographic information systems (GIS), and permanent sampling plots (PSP) were used to inventory and monitor forests in the development of an ecosystem management plan for the island of Taiwan. While the entire island has been surveyed, this study concentrates on the Hui-Sun and Hsin-Hua Experimental...

  17. A novel platform for electromagnetic navigated ultrasound bronchoscopy (EBUS).

    PubMed

    Sorger, Hanne; Hofstad, Erlend Fagertun; Amundsen, Tore; Langø, Thomas; Leira, Håkon Olav

    2016-08-01

    Endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) of mediastinal lymph nodes is essential for lung cancer staging and distinction between curative and palliative treatment. Precise sampling is crucial. Navigation and multimodal imaging may improve the efficiency of EBUS-TBNA. We demonstrate a novel EBUS-TBNA navigation system in a dedicated airway phantom. Using a convex probe EBUS bronchoscope (CP-EBUS) with an integrated sensor for electromagnetic (EM) position tracking, we performed navigated CP-EBUS in a phantom. Preoperative computed tomography (CT) and real-time ultrasound (US) images were integrated into a navigation platform for EM navigated bronchoscopy. The coordinates of targets in CT and US volumes were registered in the navigation system, and the position deviation was calculated. The system visualized all tumor models and displayed their fused CT and US images in correct positions in the navigation system. Navigating the EBUS bronchoscope was fast and easy. Mean error observed between US and CT positions for 11 target lesions (37 measurements) was [Formula: see text] mm, maximum error was 5.9 mm. The feasibility of our novel navigated CP-EBUS system was successfully demonstrated. An EBUS navigation system is needed to meet future requirements of precise mediastinal lymph node mapping, and provides new opportunities for procedure documentation in EBUS-TBNA.

  18. Metro system in Guangzhou as a hazardous reservoir of methicillin-resistant Staphylococci: findings from a point-prevalence molecular epidemiologic study.

    PubMed

    Peng, Yang; Ou, Qianting; Lin, Dongxin; Xu, Ping; Li, Ying; Ye, Xiaohua; Zhou, Junli; Yao, Zhenjiang

    2015-10-29

    Staphylococci are common causes of healthcare-associated and community-associated infections. However, limited data are available on the prevalence, phenotypes and molecular characteristics of Staphylococci in metro system around the world. 320 surface samples were collected from the Guangzhou metro system to isolate and characterize Staphylococci strains. Of the samples, 75.6% (242/320) were contaminated with Staphylococci. The Staphylococci isolates, especially the methicillin resistant isolates, were resistance to most of the antibiotics, with 79.8% (193/242) classified as multidrug resistant (MDR) strains. 8 strains of methicillin-resistant Staphylococcus aureus (MRSA) carried a range of staphylococcal cassette chromosome mec (SCCmec) types [I (1), II (3), III (2) and NT (2)]. Staphylococcus aureus isolates were classified into several ST types and showed possible cross transmissions of strains from various sources. All MRSA strains were positive for the qac gene, and only one methicillin-susceptible Staphylococci aureus (MSSA) strain was positive for the Panton-Valentine leukocidin (PVL) genes. This study demonstrated that environmental surfaces in the Guangzhou metro system may be a hazardous reservoir for transmission of Staphylococci to passengers. The resistance to antibiotics and disinfectants observed among isolates was also noteworthy.

  19. Elemental mapping in a contemporary miniature by full-field X-ray fluorescence imaging with gaseous detector vs. scanning X-ray fluorescence imaging with polycapillary optics

    NASA Astrophysics Data System (ADS)

    Silva, A. L. M.; Cirino, S.; Carvalho, M. L.; Manso, M.; Pessanha, S.; Azevedo, C. D. R.; Carramate, L. F. N. D.; Santos, J. P.; Guerra, M.; Veloso, J. F. C. A.

    2017-03-01

    Energy dispersive X-ray imaging can be used in several research fields and industrial applications. Elemental mapping through energy dispersive X-ray imaging technique has become a promising method to obtain positional distribution of specific elements in a non-destructive way. To obtain the elemental distribution of a sample it is necessary to use instruments capable of providing a precise positioning together with a good energy resolution. Polycapillary beams together with silicon drift chamber detectors are used in several commercial systems and are considered state-of-the-art spectrometers, however they are usually very costly. A new concept of large energy dispersive X-ray imaging systems based on gaseous radiation detectors emerged in the last years enabling a promising 2D elemental detection at a very reduced price. The main goal of this work is to analyze a contemporary Indian miniature with both X-ray fluorescence imaging systems, the one based on a gaseous detector 2D-THCOBRA and the state-of-the-art spectrometer M4 Tornado, from Bruker. The performance of both systems is compared and evaluated in the context of the sample's analysis.

  20. Short range radio locator system

    DOEpatents

    McEwan, Thomas E.

    1996-01-01

    A radio location system comprises a wireless transmitter that outputs two megahertz period bursts of two gigahertz radar carrier signals. A receiver system determines the position of the transmitter by the relative arrival of the radar bursts at several component receivers set up to have a favorable geometry and each one having a known location. One receiver provides a synchronizing gating pulse to itself and all the other receivers to sample the ether for the radar pulse. The rate of the synchronizing gating pulse is slightly offset from the rate of the radar bursts themselves, so that each sample collects one finely-detailed piece of information about the time-of-flight of the radar pulse to each receiver each pulse period. Thousands of sequential pulse periods provide corresponding thousand of pieces of information about the time-of-flight of the radar pulse to each receiver, in expanded, not real time. Therefore the signal processing can be done with relatively low-frequency, inexpensive components. A conventional microcomputer is then used to find the position of the transmitter by geometric triangulation based on the relative time-of-flight information.

  1. Development of an on-site screening system for amphetamine-type stimulant tablets with a portable attenuated total reflection Fourier transform infrared spectrometer.

    PubMed

    Tsujikawa, Kenji; Kuwayama, Kenji; Miyaguchi, Hajime; Kanamori, Tatsuyuki; Iwata, Yuko T; Yoshida, Takemi; Inoue, Hiroyuki

    2008-02-04

    We tried to develop a library search system using a portable, attenuated total reflection Fourier transform infrared (ATR-FT-IR) spectrometer for on-site identification of 3,4-methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyamphetamine (MDA) tablets. The library consisted of the spectra from mixtures of controlled drugs (e.g. MDMA and ketamine), adulterants (e.g. caffeine), and diluents (e.g. lactose). In the seven library search algorithms, the derivative correlation coefficient showed the best discriminant capability. This was enhanced by segmentation of the search area. The optimized search algorithm was validated by the positive (n=154, e.g. the standard mixtures containing the controlled drug, and the MDMA/MDA tablets confiscated) and negative samples (n=56, e.g. medicinal tablets). All validation samples except for four were judged truly. Final criteria for positive identification were decided on the basis of the results of the validation. In conclusion, a portable ATR-FT-IR spectrometer with our library search system would be a useful tool for on-site identification of amphetamine-type stimulant tablets.

  2. An electromagnetic/electrostatic dual cathode system for electron beam instruments

    NASA Technical Reports Server (NTRS)

    Bradley, J. G.; Conley, J. M.; Wittry, D. B.; Albee, A. L.

    1986-01-01

    A method of providing cathode redundancy which consists of two fixed cathodes and uses electromagnetic and/or electrostatic fields to direct the electron beam to the electron optical axis is presented, with application to the cathode system of the Scanning Electron Microscope and Particle Analyzer proposed for NASA's Mariner Mark II Comet Rendezvous/Asteroid Flyby projected for the 1990s. The symmetric double deflection system chosen has the optical property that the image of the effective electron source is formed above the magnet assembly near the apparent position of the effective source, and it makes the transverse positions of the electron sources independent of the electron beam energy. Good performance of the system is found, with the sample imaging resolution being the same as for the single-axis cathode.

  3. Development of an automated size-based filtration system for isolation of circulating tumor cells in lung cancer patients.

    PubMed

    Yagi, Satomi; Koh, Yasuhiro; Akamatsu, Hiroaki; Kanai, Kuninobu; Hayata, Atsushi; Tokudome, Nahomi; Akamatsu, Keiichiro; Endo, Katsuya; Nakamura, Seita; Higuchi, Masayuki; Kanbara, Hisashige; Nakanishi, Masanori; Ueda, Hiroki; Yamamoto, Nobuyuki

    2017-01-01

    Circulating tumor cells (CTCs), defined as tumor cells circulating in the peripheral blood of patients with solid tumors, are relatively rare. Diagnosis using CTCs is expected to help in the decision-making for precision cancer medicine. We have developed an automated microcavity array (MCA) system to detect CTCs based on the differences in size and deformability between tumor cells and normal blood cells. Herein, we evaluated the system using blood samples from non-small-cell lung cancer (NSCLC) and small-cell lung cancer (SCLC) patients. To evaluate the recovery of CTCs, preclinical experiments were performed by spiking NSCLC cell lines (NCI-H820, A549, NCI-H23 and NCI-H441) into peripheral whole blood samples from healthy volunteers. The recovery rates were 70% or more in all cell lines. For clinical evaluation, 6 mL of peripheral blood was collected from 50 patients with advanced lung cancer and from 10 healthy donors. Cells recovered on the filter were stained. We defined CTCs as DAPI-positive, cytokeratin-positive, and CD45-negative cells under the fluorescence microscope. The 50 lung cancer patients had a median age of 72 years (range, 48-85 years); 76% had NSCLC and 20% had SCLC, and 14% were at stage III disease whereas 86% were at stage IV. One or more CTCs were detected in 80% of the lung cancer patients (median 2.5). A comparison of the CellSearch system with our MCA system, using the samples from NSCLC patients, confirmed the superiority of our system (median CTC count, 0 versus 11 for CellSearch versus MCA; p = 0.0001, n = 17). The study results suggest that our MCA system has good clinical potential for diagnosing CTCs in lung cancer.

  4. Position-specific isotope analysis by on-line pyrolysis coupled to IRMS

    NASA Astrophysics Data System (ADS)

    Gilbert, A.; Suda, K.; Yamada, K.; Ueno, Y.; Yoshida, N.

    2016-12-01

    Position-specific isotopic analyses (PSIA) provide unique information regarding the sources, sinks and processes related to natural molecules. For instance, PSIA of short-chain hydrocarbons could lead to temperature of formation and maturity of natural gas reservoirs [1][2]. In the last decade, quantitative Nuclear Magnetic Resonance (NMR) specrometry has been used for PSIA of organic molecules such as glucose or n-alkanes [3][4]. However, due to its low sensitivity, application to low amount geochemical samples remains challenging. In 1997, Corso & Brenna proposed to adapt a pyrolysis furnace to an isotope ratio mass spectrometer, making it possible the thermal degradation of the target molecule and the subsequent analysis of the d13C values of the fragments formed [5]. Starting from fatty acid methyl esters they demonstrated the absence of rearrangement during pyrolytic degradation and could determine the d13C value of carboxyl C-atom position. We adapted the system for the full characterization of position-specific isotope composition of small molecules (ethanol, acetic acid, alanine, propane). Nanomole amount of sample can be analyzed with a precision on intramolecular d13C values of 1‰ or lower [2]. We recently analyzed abiotic and thermogenic propane samples both from the field and from lab simulations. PSIA of propane shows systematic differences of position-specific isotope composition between thermogenic and abiotic samples. While the former show 13C-depletion on the terminal C-atom position - consistent with thermal cracking kinetic models [6] - abiotic samples show little or no preference for terminal or central 13C-isotopomer. These results emphasize the potential of PSIA to trace the the processes associated with organic molecules production. [1] Piasecki et al. 2016 GCA 188, 58 [2] Gilbert et al. 2016 GCA 177, 205 [3] Gilbert et al. 2012 PNAS, 109, 18204 [4] Gilbert et al. 2013 Org. Geochem, 62, 56 [5] Corso & Brenna 1997 PNAS, 94, 1049 [6] Tang et al., 2000 GCA 64, 2673

  5. Multirate sampled-data yaw-damper and modal suppression system design

    NASA Technical Reports Server (NTRS)

    Berg, Martin C.; Mason, Gregory S.

    1990-01-01

    A multirate control law synthesized algorithm based on an infinite-time quadratic cost function, was developed along with a method for analyzing the robustness of multirate systems. A generalized multirate sampled-data control law structure (GMCLS) was introduced. A new infinite-time-based parameter optimization multirate sampled-data control law synthesis method and solution algorithm were developed. A singular-value-based method for determining gain and phase margins for multirate systems was also developed. The finite-time-based parameter optimization multirate sampled-data control law synthesis algorithm originally intended to be applied to the aircraft problem was instead demonstrated by application to a simpler problem involving the control of the tip position of a two-link robot arm. The GMCLS, the infinite-time-based parameter optimization multirate control law synthesis method and solution algorithm, and the singular-value based method for determining gain and phase margins were all demonstrated by application to the aircraft control problem originally proposed for this project.

  6. Constant pressure high throughput membrane permeation testing system

    DOEpatents

    Albenze, Erik J.; Hopkinson, David P.; Luebke, David R.

    2014-09-02

    The disclosure relates to a membrane testing system for individual evaluation of a plurality of planar membranes subjected to a feed gas on one side and a sweep gas on a second side. The membrane testing system provides a pressurized flow of a feed and sweep gas to each membrane testing cell in a plurality of membrane testing cells while a stream of retentate gas from each membrane testing cell is ported by a retentate multiport valve for sampling or venting, and a stream of permeate gas from each membrane testing cell is ported by a permeate multiport valve for sampling or venting. Back pressure regulators and mass flow controllers act to maintain substantially equivalent gas pressures and flow rates on each side of the planar membrane throughout a sampling cycle. A digital controller may be utilized to position the retentate and permeate multiport valves cyclically, allowing for gas sampling of different membrane cells over an extended period of time.

  7. Model-Based Adaptive Event-Triggered Control of Strict-Feedback Nonlinear Systems.

    PubMed

    Li, Yuan-Xin; Yang, Guang-Hong

    2018-04-01

    This paper is concerned with the adaptive event-triggered control problem of nonlinear continuous-time systems in strict-feedback form. By using the event-sampled neural network (NN) to approximate the unknown nonlinear function, an adaptive model and an associated event-triggered controller are designed by exploiting the backstepping method. In the proposed method, the feedback signals and the NN weights are aperiodically updated only when the event-triggered condition is violated. A positive lower bound on the minimum intersample time is guaranteed to avoid accumulation point. The closed-loop stability of the resulting nonlinear impulsive dynamical system is rigorously proved via Lyapunov analysis under an adaptive event sampling condition. In comparing with the traditional adaptive backstepping design with a fixed sample period, the event-triggered method samples the state and updates the NN weights only when it is necessary. Therefore, the number of transmissions can be significantly reduced. Finally, two simulation examples are presented to show the effectiveness of the proposed control method.

  8. Evaluation of an automated microplate technique in the Galileo system for ABO and Rh(D) blood grouping.

    PubMed

    Xu, Weiyi; Wan, Feng; Lou, Yufeng; Jin, Jiali; Mao, Weilin

    2014-01-01

    A number of automated devices for pretransfusion testing have recently become available. This study evaluated the Immucor Galileo System, a fully automated device based on the microplate hemagglutination technique for ABO/Rh (D) determinations. Routine ABO/Rh typing tests were performed on 13,045 samples using the Immucor automated instruments. Manual tube method was used to resolve ABO forward and reverse grouping discrepancies. D-negative test results were investigated and confirmed manually by the indirect antiglobulin test (IAT). The system rejected 70 tests for sample inadequacy. 87 samples were read as "No-type-determined" due to forward and reverse grouping discrepancies. 25 tests gave these results because of sample hemolysis. After further tests, we found 34 tests were caused by weakened RBC antibodies, 5 tests were attributable to weak A and/or B antigens, 4 tests were due to mixed-field reactions, and 8 tests had high titer cold agglutinin with blood qualifications which react only at temperatures below 34 degrees C. In the remaining 11 cases, irregular RBC antibodies were identified in 9 samples (seven anti-M and two anti-P) and two subgroups were identified in 2 samples (one A1 and one A2) by a reference laboratory. As for D typing, 2 weak D+ samples missed by automated systems gave negative results, but weak-positive reactions were observed in the IAT. The Immucor Galileo System is reliable and suited for ABO and D blood groups, some reasons may cause a discrepancy in ABO/D typing using a fully automated system. It is suggested that standardization of sample collection may improve the performance of the fully automated system.

  9. Development of a versatile user-friendly IBA experimental chamber

    NASA Astrophysics Data System (ADS)

    Kakuee, Omidreza; Fathollahi, Vahid; Lamehi-Rachti, Mohammad

    2016-03-01

    Reliable performance of the Ion Beam Analysis (IBA) techniques is based on the accurate geometry of the experimental setup, employment of the reliable nuclear data and implementation of dedicated analysis software for each of the IBA techniques. It has already been shown that geometrical imperfections lead to significant uncertainties in quantifications of IBA measurements. To minimize these uncertainties, a user-friendly experimental chamber with a heuristic sample positioning system for IBA analysis was recently developed in the Van de Graaff laboratory in Tehran. This system enhances IBA capabilities and in particular Nuclear Reaction Analysis (NRA) and Elastic Recoil Detection Analysis (ERDA) techniques. The newly developed sample manipulator provides the possibility of both controlling the tilt angle of the sample and analyzing samples with different thicknesses. Moreover, a reasonable number of samples can be loaded in the sample wheel. A comparison of the measured cross section data of the 16O(d,p1)17O reaction with the data reported in the literature confirms the performance and capability of the newly developed experimental chamber.

  10. A new technique based on current measurement for nanoscale ferroelectricity assessment: Nano-positive up negative down

    NASA Astrophysics Data System (ADS)

    Martin, Simon; Baboux, Nicolas; Albertini, David; Gautier, Brice

    2017-02-01

    In this paper, we propose a new procedure which aims at measuring the polarisation switching current at the nanoscale on ferroelectric thin films with the atomic force microscope tip used as a top electrode. Our technique is an adaptation of the so-called positive up negative down method commonly operated on large electrodes. The main obstacle that must be overcome to implement such measurement is the enhancement of the signal to noise ratio, in a context where the stray capacitance of the sample/tip/lever/lever holder system generates a dielectric displacement current several orders of magnitude higher than the current to be measured. This problem is solved by the subtraction of the displacement current through a reference capacitance. For the first time, we show an example of nanoscale positive up negative down measurement of the polarisation charge on a PbZrTiO3 thin film and compare the measured value with paraelectric samples. From the comparison with macroscopic measurement, we deduce the effective area of contact between the tip and the sample.

  11. Evaluation of a new monochloramine generation system for controlling Legionella in building hot water systems.

    PubMed

    Duda, Scott; Kandiah, Sheena; Stout, Janet E; Baron, Julianne L; Yassin, Mohamed; Fabrizio, Marie; Ferrelli, Juliet; Hariri, Rahman; Wagener, Marilyn M; Goepfert, John; Bond, James; Hannigan, Joseph; Rogers, Denzil

    2014-11-01

    To evaluate the efficacy of a new monochloramine generation system for control of Legionella in a hospital hot water distribution system. A 495-bed tertiary care hospital in Pittsburgh, Pennsylvania. The hospital has 12 floors covering approximately 78,000 m(2). The hospital hot water system was monitored for a total of 29 months, including a 5-month baseline sampling period prior to installation of the monochloramine system and 24 months of surveillance after system installation (postdisinfection period). Water samples were collected for microbiological analysis (Legionella species, Pseudomonas aeruginosa, Stenotrophomonas maltophilia, Acinetobacter species, nitrifying bacteria, heterotrophic plate count [HPC] bacteria, and nontuberculous mycobacteria). Chemical parameters monitored during the investigation included monochloramine, chlorine (free and total), nitrate, nitrite, total ammonia, copper, silver, lead, and pH. A significant reduction in Legionella distal site positivity was observed between the pre- and postdisinfection periods, with positivity decreasing from an average of 53% (baseline) to an average of 9% after monochloramine application (P<0.5]). Although geometric mean HPC concentrations decreased by approximately 2 log colony-forming units per milliliter during monochloramine treatment, we did not observe significant changes in other microbial populations. This is the first evaluation in the United States of a commercially available monochloramine system installed on a hospital hot water system for Legionella disinfection, and it demonstrated a significant reduction in Legionella colonization. Significant increases in microbial populations or other negative effects previously associated with monochloramine use in large municipal cold water systems were not observed.

  12. Genotyping of samples from German patients with ocular, cerebral and systemic toxoplasmosis reveals a predominance of Toxoplasma gondii type II.

    PubMed

    Herrmann, Daland C; Maksimov, Pavlo; Hotop, Andrea; Groß, Uwe; Däubener, Walter; Liesenfeld, Oliver; Pleyer, Uwe; Conraths, Franz J; Schares, Gereon

    2014-10-01

    Toxoplasmosis is an important zoonosis transmitted from animals to humans world-wide. In order to determine Toxoplasma gondii genotypes in individuals living in Germany and to compare findings with those in animals, we analysed nine independent and unlinked genetic markers (nSAG2, SAG3, BTUB, GRA6, c22-8, c29-2, L358, PK1 and Apico) by PCR-RFLP in 83 archived T. gondii-positive DNA samples from patients with ocular toxoplasmosis (n=35), toxoplasmic encephalitis (n=32), systemic toxoplasmosis after bone-marrow transplantation (n=15) and congenital toxoplasmosis (n=1). In 46 of these 83 samples the presence of T. gondii DNA was confirmed by conventional end-point PCR. Among these, 17 T. gondii-positive samples were typed at all nine loci. The majority (15/17, 88.2%) of these samples were of T. gondii type II (i.e., including both, the Apico type II and Apico type I variants). In addition, in one sample a T. gondii type II/type III allele combination and in another sample a T. gondii genotype displaying type III alleles at all markers was observed. In the remaining 11 samples, in which T. gondii could only be partially typed, exclusively type II (n=10) or type III (n=1) alleles were observed. Results of the present study suggest that the majority of patients in Germany are infected with type II T. gondii regardless of the clinical manifestation of toxoplasmosis. This finding is in accord with the predominance of type II T. gondii in oocysts isolated from cats and in tissues of other intermediate hosts in Germany. Copyright © 2014 Elsevier GmbH. All rights reserved.

  13. [A quickly methodology for drug intelligence using profiling of illicit heroin samples].

    PubMed

    Zhang, Jianxin; Chen, Cunyi

    2012-07-01

    The aim of the paper was to evaluate a link between two heroin seizures using a descriptive method. The system involved the derivation and gas chromatographic separation of samples followed by a fully automatic data analysis and transfer to a database. Comparisons used the square cosine function between two chromatograms assimilated to vectors. The method showed good discriminatory capabilities. The probability of false positives was extremely slight. In conclusion, this method proved to be efficient and reliable, which appeared suitable for estimating the links between illicit heroin samples.

  14. Assessment of the National Research Universal Reactor Proposed New Stack Sampling Probe Location for Compliance with ANSI/HPS N13.1-1999

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glissmeyer, John A.; Antonio, Ernest J.; Flaherty, Julia E.

    2016-02-29

    This document reports on a series of tests conducted to assess the proposed air sampling location for the National Research Universal reactor (NRU) complex exhaust stack, located in Chalk River, Ontario, Canada, with respect to the applicable criteria regarding the placement of an air sampling probe. Due to the age of the equipment in the existing monitoring system, and the increasing difficulty in acquiring replacement parts to maintain this equipment, a more up-to-date system is planned to replace the current effluent monitoring system, and a new monitoring location has been proposed. The new sampling probe should be located within themore » exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream. The internal Pacific Northwest National Laboratory (PNNL) project for this task was 65167, Atomic Energy Canada Ltd. Chalk River Effluent Duct Flow Qualification. The testing described in this document was guided by the Test Plan: Testing of the NRU Stack Air Sampling Position (TP-STMON-032).« less

  15. Position specific morphological characteristics of top-level male handball players.

    PubMed

    Srhoj, V; Marinović, M; Rogulj, N

    2002-06-01

    With the aim of determining the common morphological features of senior male handball players and of analyzing their specificities i.e. the probable variation between the four playing positions (back court players, wings, pivots, goalkeepers), 25 anthropometric measures were applied to the sample of 49 players, members of three top-quality handball teams. The basic descriptive parameters were calculated and then an analysis of variance and a cluster analysis were performed. A mesomorphic, athletic body- type was obtained with a marked longitudinal skeleton dimensionality, but also with a balanced ratio between the skeletal system and muscle mass and with low values of subcutaneous fat tissue. Back court players and goalkeepers are superior in terms of outstanding skeletal dimensions and circumferences. Line players, i.e. wings and pivots, have somewhat lower longitudinal measures, whereas pronounced voluminosity and a slightly higher fat tissue value differentiate pivots from players in other positions. Cluster analysis revealed a greater homogeneity in the morphological profiles of the samples of line players (wings and pivots) than in the profiles of backs or goalkeepers. The obtained position-related differences in morphological characteristics of players suggest that the experienced players from the sample were earlier successfully subjected to the selection process and oriented to a particular playing position because of the observed correspondence between their body-type and specific kinesiological demands of the position in question. Therefore, in top-quality team-handball it would be recommendable to select players whose morphological profiles are as compatible as possible with positional specificities in the demand for the game.

  16. A Study of Vicon System Positioning Performance.

    PubMed

    Merriaux, Pierre; Dupuis, Yohan; Boutteau, Rémi; Vasseur, Pascal; Savatier, Xavier

    2017-07-07

    Motion capture setups are used in numerous fields. Studies based on motion capture data can be found in biomechanical, sport or animal science. Clinical science studies include gait analysis as well as balance, posture and motor control. Robotic applications encompass object tracking. Today's life applications includes entertainment or augmented reality. Still, few studies investigate the positioning performance of motion capture setups. In this paper, we study the positioning performance of one player in the optoelectronic motion capture based on markers: Vicon system. Our protocol includes evaluations of static and dynamic performances. Mean error as well as positioning variabilities are studied with calibrated ground truth setups that are not based on other motion capture modalities. We introduce a new setup that enables directly estimating the absolute positioning accuracy for dynamic experiments contrary to state-of-the art works that rely on inter-marker distances. The system performs well on static experiments with a mean absolute error of 0.15 mm and a variability lower than 0.025 mm. Our dynamic experiments were carried out at speeds found in real applications. Our work suggests that the system error is less than 2 mm. We also found that marker size and Vicon sampling rate must be carefully chosen with respect to the speed encountered in the application in order to reach optimal positioning performance that can go to 0.3 mm for our dynamic study.

  17. Modification of the BAX Salmonella test kit to include a hot start functionality (modification of AOAC Official Method 2003.09).

    PubMed

    Wallace, F Morgan; DiCosimo, Deana; Farnum, Andrew; Tice, George; Andaloro, Bridget; Davis, Eugene; Burns, Frank R

    2011-01-01

    In 2010, the BAX System PCR assay for Salmonella was modified to include a hot start functionality designed to keep the reaction enzyme inactive until PCR begins. To validate the assay's Official Methods of Analysis status to include this procedure modification, an evaluation was conducted on four food types that were simultaneously analyzed with the BAX System and either the U.S. Food and Drug Administration's Bacteriological Analytical Manual or the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook reference method for detecting Salmonella. Identical performance between the BAX System method and the reference methods was observed. Additionally, lysates were analyzed using both the BAX System Classic and BAX System Q7 instruments with identical results using both platforms for all samples tested. Of the 100 samples analyzed, 34 samples were positive for both the BAX System and reference methods, and 66 samples were negative by both the BAX System and reference methods, demonstrating 100% correlation. No instrument platform variation was observed. Additional inclusivity and exclusivity testing using the modified test kit demonstrated the test kit to be 100% accurate in evaluation of test panels of 352 Salmonella strains and 46 non-Salmonella strains.

  18. Performance Evaluation and Analysis for Gravity Matching Aided Navigation.

    PubMed

    Wu, Lin; Wang, Hubiao; Chai, Hua; Zhang, Lu; Hsu, Houtse; Wang, Yong

    2017-04-05

    Simulation tests were accomplished in this paper to evaluate the performance of gravity matching aided navigation (GMAN). Four essential factors were focused in this study to quantitatively evaluate the performance: gravity database (DB) resolution, fitting degree of gravity measurements, number of samples in matching, and gravity changes in the matching area. Marine gravity anomaly DB derived from satellite altimetry was employed. Actual dynamic gravimetry accuracy and operating conditions were referenced to design the simulation parameters. The results verified that the improvement of DB resolution, gravimetry accuracy, number of measurement samples, or gravity changes in the matching area generally led to higher positioning accuracies, while the effects of them were different and interrelated. Moreover, three typical positioning accuracy targets of GMAN were proposed, and the conditions to achieve these targets were concluded based on the analysis of several different system requirements. Finally, various approaches were provided to improve the positioning accuracy of GMAN.

  19. Performance Evaluation and Analysis for Gravity Matching Aided Navigation

    PubMed Central

    Wu, Lin; Wang, Hubiao; Chai, Hua; Zhang, Lu; Hsu, Houtse; Wang, Yong

    2017-01-01

    Simulation tests were accomplished in this paper to evaluate the performance of gravity matching aided navigation (GMAN). Four essential factors were focused in this study to quantitatively evaluate the performance: gravity database (DB) resolution, fitting degree of gravity measurements, number of samples in matching, and gravity changes in the matching area. Marine gravity anomaly DB derived from satellite altimetry was employed. Actual dynamic gravimetry accuracy and operating conditions were referenced to design the simulation parameters. The results verified that the improvement of DB resolution, gravimetry accuracy, number of measurement samples, or gravity changes in the matching area generally led to higher positioning accuracies, while the effects of them were different and interrelated. Moreover, three typical positioning accuracy targets of GMAN were proposed, and the conditions to achieve these targets were concluded based on the analysis of several different system requirements. Finally, various approaches were provided to improve the positioning accuracy of GMAN. PMID:28379178

  20. Performing Isoelectric Focusing and Simultaneous Fractionation of Proteins on A Rotary Valve Followed by Sodium Dodecyl – Polyacrylamide Gel Electrophoresis

    PubMed Central

    Wang, Wei; Lu, Joann J.; Gu, Congying; Zhou, Lei; Liu, Shaorong

    2013-01-01

    In this technical note, we design and fabricate a novel rotary valve and demonstrate its feasibility for performing isoelectric focusing and simultaneous fractionation of proteins, followed by sodium dodecyl – polyacrylamide gel electrophoresis. The valve has two positions. In one position, the valve routes a series of capillary loops together into a single capillary tube where capillary isoelectric focusing (CIEF) is performed. By switching the valve to another position, the CIEF-resolved proteins in all capillary loops are isolated simultaneously, and samples in the loops are removed and collected in vials. After the collected samples are briefly processed, they are separated via sodium dodecyl – polyacrylamide gel electrophoresis (SDS-PAGE, the 2nd-D separation) on either a capillary gel electrophoresis instrument or a slab-gel system. The detailed valve configuration is illustrated, and the experimental conditions and operation protocols are discussed. PMID:23819755

  1. False positive acetaminophen concentrations in patients with liver injury.

    PubMed

    Polson, Julie; Wians, Frank H; Orsulak, Paul; Fuller, Dwain; Murray, Natalie G; Koff, Jonathan M; Khan, Adil I; Balko, Jody A; Hynan, Linda S; Lee, William M

    2008-05-01

    Acetaminophen toxicity is the most common form of acute liver failure in the U.S. After acetaminophen overdoses, quantitation of plasma acetaminophen can aid in predicting severity of injury. However, recent case reports have suggested that acetaminophen concentrations may be falsely increased in the presence of hyperbilirubinemia. We tested sera obtained from 43 patients with acute liver failure, mostly unrelated to acetaminophen, utilizing 6 different acetaminophen quantitation systems to determine the significance of this effect. In 36 of the 43 samples with bilirubin concentrations ranging from 1.0-61.5 mg/dl no acetaminophen was detectable by gas chromatography-mass spectroscopy. These 36 samples were then utilized to test the performance characteristics of 2 immunoassay and 4 enzymatic-colorimetric methods. Three of four colorimetric methods demonstrated 'detectable' values for acetaminophen in from 4 to 27 of the 36 negative samples, low concentration positive values being observed when serum bilirubin concentrations exceeded 10 mg/dl. By contrast, the 2 immunoassay methods (EMIT, FPIA) were virtually unaffected. The false positive values obtained were, in general, proportional to the quantity of bilirubin in the sample. However, prepared samples of normal human serum with added bilirubin showed a dose-response curve for only one of the 4 colorimetric assays. False positive acetaminophen tests may result when enzymatic-colorimetric assays are used, most commonly with bilirubin concentrations >10 mg/dl, leading to potential clinical errors in this setting. Bilirubin (or possibly other substances in acute liver failure sera) appears to affect the reliable measurement of acetaminophen, particularly with enzymatic-colorimetric assays.

  2. Real-Time Detection Method And System For Identifying Individual Aerosol Particles

    DOEpatents

    Gard, Eric Evan; Fergenson, David Philip

    2005-10-25

    A method and system of identifying individual aerosol particles in real time. Sample aerosol particles are compared against and identified with substantially matching known particle types by producing positive and negative test spectra of an individual aerosol particle using a bipolar single particle mass spectrometer. Each test spectrum is compared to spectra of the same respective polarity in a database of predetermined positive and negative spectra for known particle types and a set of substantially matching spectra is obtained. Finally the identity of the individual aerosol particle is determined from the set of substantially matching spectra by determining a best matching one of the known particle types having both a substantially matching positive spectrum and a substantially matching negative spectrum associated with the best matching known particle type.

  3. Laboratory evaluation of 3M Petrifilms and University of Minnesota Bi-plates as potential on-farm tests for clinical mastitis.

    PubMed

    McCarron, J L; Keefe, G P; McKenna, S L B; Dohoo, I R; Poole, D E

    2009-05-01

    The objective was to determine test characteristics and compare 2 potential on-farm culture systems for clinical mastitis, the Minnesota Easy Culture System II Bi-plate and Petrifilm. The tests were evaluated using clinically positive mastitic milk samples (n = 282) to determine their ability to differentiate appropriate treatment groups; all cases that had gram-positive growth were considered treatment candidates (n = 161), whereas cases that grew gram-negative organisms only or yielded no bacterial growth were classified as no treatment (n = 121). For Petrifilm, both undiluted and 1:10 diluted milk samples were used. To create treatment categories, 2 types of Petrifilms were used, Aerobic Count (AC) and Coliform Count (CC). Both Bi-plates and Petrifilms were read after 24 h of incubation. Analysis was conducted at various colony count thresholds for the Petrifilm test system. The combination of Petrifilms that had the highest sensitivity classified a case as gram-negative if there were > or =20 colonies present on the CC. If there were <20 colonies present on the CC and >5 colonies present on the AC, a case would be classified as gram-positive. The Bi-plate had a sensitivity of 97.9% and a specificity of 68.6%. The Petrifilm test system had a sensitivity of 93.8% and a specificity of 70.1%. There was no significant difference in the sensitivities between the tests. All Bi-plates and Petrifilms were read by a laboratory technician and a group of masked readers with limited microbiology training. Kappa values for the masked readers were 0.75 for Bi-plates and 0.84 and 0.86 for AC and CC Petrifilms, respectively. The Bi-plate and Petrifilm were able to successfully categorize clinical cases of mastitis into 2 treatments based on their ability to detect the presence of a gram-positive organism. Neither method had the ability to determine if a sample was contaminated. The results of this study indicate that both tests were able to appropriately categorize cases, which could potentially result in a reduction in the quantity of antibiotics used to treat clinical cases of mastitis.

  4. Performance comparison of two androgen receptor splice variant 7 (AR-V7) detection methods.

    PubMed

    Bernemann, Christof; Steinestel, Julie; Humberg, Verena; Bögemann, Martin; Schrader, Andres Jan; Lennerz, Jochen K

    2018-01-23

    To compare the performance of two established androgen receptor splice variant 7 (AR-V7) mRNA detection systems, as paradoxical responses to next-generation androgen-deprivation therapy in AR-V7 mRNA-positive circulating tumour cells (CTC) of patients with castration-resistant prostate cancer (CRPC) could be related to false-positive classification using detection systems with different sensitivities. We compared the performance of two established mRNA-based AR-V7 detection technologies using either SYBR Green or TaqMan chemistries. We assessed in vitro performance using eight genitourinary cancer cell lines and serial dilutions in three AR-V7-positive prostate cancer cell lines, as well as in 32 blood samples from patients with CRPC. Both assays performed identically in the cell lines and serial dilutions showed identical diagnostic thresholds. Performance comparison in 32 clinical patient samples showed perfect concordance between the assays. In particular, both assays determined AR-V7 mRNA-positive CTCs in three patients with unexpected responses to next-generation anti-androgen therapy. Thus, technical differences between the assays can be excluded as the underlying reason for the unexpected responses to next-generation anti-androgen therapy in a subset of AR-V7 patients. Irrespective of the method used, patients with AR-V7 mRNA-positive CRPC should not be systematically precluded from an otherwise safe treatment option. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  5. Development of a Hybrid Atomic Force Microscopic Measurement System Combined with White Light Scanning Interferometry

    PubMed Central

    Guo, Tong; Wang, Siming; Dorantes-Gonzalez, Dante J.; Chen, Jinping; Fu, Xing; Hu, Xiaotang

    2012-01-01

    A hybrid atomic force microscopic (AFM) measurement system combined with white light scanning interferometry for micro/nanometer dimensional measurement is developed. The system is based on a high precision large-range positioning platform with nanometer accuracy on which a white light scanning interferometric module and an AFM head are built. A compact AFM head is developed using a self-sensing tuning fork probe. The head need no external optical sensors to detect the deflection of the cantilever, which saves room on the head, and it can be directly fixed under an optical microscopic interferometric system. To enhance the system’s dynamic response, the frequency modulation (FM) mode is adopted for the AFM head. The measuring data can be traceable through three laser interferometers in the system. The lateral scanning range can reach 25 mm × 25 mm by using a large-range positioning platform. A hybrid method combining AFM and white light scanning interferometry is proposed to improve the AFM measurement efficiency. In this method, the sample is measured firstly by white light scanning interferometry to get an overall coarse morphology, and then, further measured with higher resolution by AFM. Several measuring experiments on standard samples demonstrate the system’s good measurement performance and feasibility of the hybrid measurement method. PMID:22368463

  6. Application of PCR to a clinical and environmental investigation of a case of equine botulism.

    PubMed

    Szabo, E A; Pemberton, J M; Gibson, A M; Thomas, R J; Pascoe, R R; Desmarchelier, P M

    1994-08-01

    PCR for the detection of botulinum neurotoxin gene types A to E was used in the investigation of a case of equine botulism. Samples from a foal diagnosed with toxicoinfectious botulism in 1985 were reanalyzed by PCR and the mouse bioassay in conjunction with an environmental survey. Neurotoxin B was detected by mouse bioassay in culture enrichments of serum, spleen, feces, and intestinal contents. PCR results compared well with mouse bioassay results, detecting type B neurotoxin genes in these samples and also in a liver sample. Other neurotoxin types were not detected by either test. Clostridium botulinum type B was shown to be prevalent in soils collected from the area in which the foal was raised. Four methods were used to test for the presence of botulinum neurotoxin-producing organisms in 66 soil samples taken within a 5-km radius: PCR and agarose gel electrophoresis (types A to E), PCR and an enzyme-linked assay (type B), hybridization of crude alkaline cell lysates with a type B-specific probe, and the mouse bioassay (all types). Fewer soil samples were positive for C. botulinum type B by the mouse bioassay (15%) than by any of the DNA-based detection systems. Hybridization of a type B-specific probe to DNA dot blots (26% of the samples were positive) and PCR-enzyme-linked assay (77% of the samples were positive) were used for the rapid analysis of large numbers of samples, with sensitivity limits of 3 x 10(6) and 3,000 cells, respectively. Conventional detection of PCR products by gel electrophoresis was the most sensitive method (300-cell limit), and in the present environmental survey, neurotoxin B genes only were detected in 94% of the samples.

  7. Application of PCR to a clinical and environmental investigation of a case of equine botulism.

    PubMed Central

    Szabo, E A; Pemberton, J M; Gibson, A M; Thomas, R J; Pascoe, R R; Desmarchelier, P M

    1994-01-01

    PCR for the detection of botulinum neurotoxin gene types A to E was used in the investigation of a case of equine botulism. Samples from a foal diagnosed with toxicoinfectious botulism in 1985 were reanalyzed by PCR and the mouse bioassay in conjunction with an environmental survey. Neurotoxin B was detected by mouse bioassay in culture enrichments of serum, spleen, feces, and intestinal contents. PCR results compared well with mouse bioassay results, detecting type B neurotoxin genes in these samples and also in a liver sample. Other neurotoxin types were not detected by either test. Clostridium botulinum type B was shown to be prevalent in soils collected from the area in which the foal was raised. Four methods were used to test for the presence of botulinum neurotoxin-producing organisms in 66 soil samples taken within a 5-km radius: PCR and agarose gel electrophoresis (types A to E), PCR and an enzyme-linked assay (type B), hybridization of crude alkaline cell lysates with a type B-specific probe, and the mouse bioassay (all types). Fewer soil samples were positive for C. botulinum type B by the mouse bioassay (15%) than by any of the DNA-based detection systems. Hybridization of a type B-specific probe to DNA dot blots (26% of the samples were positive) and PCR-enzyme-linked assay (77% of the samples were positive) were used for the rapid analysis of large numbers of samples, with sensitivity limits of 3 x 10(6) and 3,000 cells, respectively. Conventional detection of PCR products by gel electrophoresis was the most sensitive method (300-cell limit), and in the present environmental survey, neurotoxin B genes only were detected in 94% of the samples. Images PMID:7989554

  8. Accuracy and precision of Legionella isolation by US laboratories in the ELITE program pilot study.

    PubMed

    Lucas, Claressa E; Taylor, Thomas H; Fields, Barry S

    2011-10-01

    A pilot study for the Environmental Legionella Isolation Techniques Evaluation (ELITE) Program, a proficiency testing scheme for US laboratories that culture Legionella from environmental samples, was conducted September 1, 2008 through March 31, 2009. Participants (n=20) processed panels consisting of six sample types: pure and mixed positive, pure and mixed negative, pure and mixed variable. The majority (93%) of all samples (n=286) were correctly characterized, with 88.5% of samples positive for Legionella and 100% of negative samples identified correctly. Variable samples were incorrectly identified as negative in 36.9% of reports. For all samples reported positive (n=128), participants underestimated the cfu/ml by a mean of 1.25 logs with standard deviation of 0.78 logs, standard error of 0.07 logs, and a range of 3.57 logs compared to the CDC re-test value. Centering results around the interlaboratory mean yielded a standard deviation of 0.65 logs, standard error of 0.06 logs, and a range of 3.22 logs. Sampling protocol, treatment regimen, culture procedure, and laboratory experience did not significantly affect the accuracy or precision of reported concentrations. Qualitative and quantitative results from the ELITE pilot study were similar to reports from a corresponding proficiency testing scheme available in the European Union, indicating these results are probably valid for most environmental laboratories worldwide. The large enumeration error observed suggests that the need for remediation of a water system should not be determined solely by the concentration of Legionella observed in a sample since that value is likely to underestimate the true level of contamination. Published by Elsevier Ltd.

  9. Fiber laser-microscope system for femtosecond photodisruption of biological samples

    PubMed Central

    Yavaş, Seydi; Erdogan, Mutlu; Gürel, Kutan; Ilday, F. Ömer; Eldeniz, Y. Burak; Tazebay, Uygar H.

    2012-01-01

    We report on the development of a ultrafast fiber laser-microscope system for femtosecond photodisruption of biological targets. A mode-locked Yb-fiber laser oscillator generates few-nJ pulses at 32.7 MHz repetition rate, amplified up to ∼125 nJ at 1030 nm. Following dechirping in a grating compressor, ∼240 fs-long pulses are delivered to the sample through a diffraction-limited microscope, which allows real-time imaging and control. The laser can generate arbitrary pulse patterns, formed by two acousto-optic modulators (AOM) controlled by a custom-developed field-programmable gate array (FPGA) controller. This capability opens the route to fine optimization of the ablation processes and management of thermal effects. Sample position, exposure time and imaging are all computerized. The capability of the system to perform femtosecond photodisruption is demonstrated through experiments on tissue and individual cells. PMID:22435105

  10. MultiFocus Polarization Microscope (MF-PolScope) for 3D polarization imaging of up to 25 focal planes simultaneously

    PubMed Central

    Abrahamsson, Sara; McQuilken, Molly; Mehta, Shalin B.; Verma, Amitabh; Larsch, Johannes; Ilic, Rob; Heintzmann, Rainer; Bargmann, Cornelia I.; Gladfelter, Amy S.; Oldenbourg, Rudolf

    2015-01-01

    We have developed an imaging system for 3D time-lapse polarization microscopy of living biological samples. Polarization imaging reveals the position, alignment and orientation of submicroscopic features in label-free as well as fluorescently labeled specimens. Optical anisotropies are calculated from a series of images where the sample is illuminated by light of different polarization states. Due to the number of images necessary to collect both multiple polarization states and multiple focal planes, 3D polarization imaging is most often prohibitively slow. Our MF-PolScope system employs multifocus optics to form an instantaneous 3D image of up to 25 simultaneous focal-planes. We describe this optical system and show examples of 3D multi-focus polarization imaging of biological samples, including a protein assembly study in budding yeast cells. PMID:25837112

  11. Advances in structural monitoring with Global Positioning System technology: 1997-2006

    NASA Astrophysics Data System (ADS)

    Ogaja, Clement; Li, Xiaojing; Rizos, Chris

    2007-11-01

    Over the last decade, users of the Global Positioning System (GPS) have developed the technology capable of meeting stringent requirements to study the dynamics of tall buildings, towers, and bridges during earthquakes, wind-induced deformation and traffic loading. Dynamic measurements of relative displacements of structures is currently possible using real-time kinematic (RTK) positioning techniques, now advanced to record typically at 10-20 Hz (or higher - e.g., 100 Hz) with an accuracy of ±1 cm horizontally and ±2 cm vertically. With further advances in the technology and improvements in sampling capability, it is possible to meet the needs of real-time displacement information for the structural engineering community. After a decade of great strides in proving the feasibility of the technology, focus is moving to sensor integration and operational systems. Several investigators are now routinely researching the integration of GPS with other sensors (accelerometers, fibre optics, pseudolites, etc.) to utilise the complementary benefits and overcome limitations of the individual systems. Examples of real-time operational systems exist to demonstrate the significance of GPS technology in measuring the dynamic behaviour of large engineering structures.

  12. Depth-resolved measurement of ocular fundus pulsations by low-coherence tissue interferometry

    NASA Astrophysics Data System (ADS)

    Dragostinoff, Nikolaus; Werkmeister, René M.; Gröschl, Martin; Schmetterer, Leopold

    2009-09-01

    A device that allows for the measurement of ocular fundus pulsations at preselected axial positions of a subject's eye is presented. Unlike previously presented systems, which only allow for observation of the strongest reflecting retinal layer, our system enables the measurement of fundus pulsations at a preselected ocular layer. For this purpose the sample is illuminated by light of low temporal coherence. The layer is then selected by positioning one mirror of a Michelson interferometer according to the depth of the layer. The device contains a length measurement system based on partial coherence interferometry and a line scan charge-coupled device camera for recording and online inspection of the fringe system. In-vivo measurements in healthy humans are performed as proof of principle. The algorithms used for enhancing the recorded images are briefly introduced. The contrast of the observed interference pattern is evaluated for different positions of the measurement mirror and at various distances from the front surface of the cornea. The applications of such a system may be wide, including assessment of eye elongation during myopia development and blood-flow-related changes in intraocular volume.

  13. Upregulating the positive affect system in anxiety and depression: Outcomes of a positive activity intervention.

    PubMed

    Taylor, Charles T; Lyubomirsky, Sonja; Stein, Murray B

    2017-03-01

    Research suggests that the positive affect system may be an important yet underexplored treatment target in anxiety and depression. Existing interventions primarily target the negative affect system, yielding modest effects on measures of positive emotions and associated outcomes (e.g., psychological well-being). The objective of the present pilot study was to evaluate the efficacy of a new transdiagnostic positive activity intervention (PAI) for anxiety and depression. Twenty-nine treatment-seeking individuals presenting with clinically impairing symptoms of anxiety and/or depression were randomly allocated to a 10-session protocol comprised of PAIs previously shown in nonclinical samples to improve positive thinking, emotions, and behaviors (e.g., gratitude, acts of kindness, optimism; n = 16) or a waitlist (WL) condition (n = 13). Participants were assessed at pre- and posttreatment, as well as 3- and 6-month follow-up, on measures of positive and negative affect, symptoms, and psychological well-being. ClinicalTrials.gov Identifier: NCT02330627 RESULTS: The PAI group displayed significantly larger improvements in positive affect and psychological well-being from pre- to posttreatment compared to WL. Posttreatment and follow-up scores in the PAI group were comparable to general population norms. The PAI regimen also resulted in significantly larger reductions in negative affect, as well as anxiety and depression symptoms, compared to WL. Improvements across all outcomes were large in magnitude and maintained over a 6-month follow-up period. Targeting the positive affect system through a multicomponent PAI regimen may be beneficial for generating improvements in positive emotions and well-being, as well as reducing negative affect and symptoms, in individuals with clinically impairing anxiety or depression. © 2016 Wiley Periodicals, Inc.

  14. Performance of Mycobacterium Growth Indicator Tube BACTEC 960 with Lowenstein-Jensen method for diagnosis of Mycobacterium tuberculosis at Ethiopian National Tuberculosis Reference Laboratory, Addis Ababa, Ethiopia.

    PubMed

    Diriba, Getu; Kebede, Abebaw; Yaregal, Zelalem; Getahun, Muluwork; Tadesse, Mengistu; Meaza, Abyot; Dagne, Zekarias; Moga, Shewki; Dilebo, Jibril; Gudena, Kebebe; Hassen, Mulu; Desta, Kassu

    2017-05-10

    Bacteriological confirmed active case detection remains the corner stone for diagnosing tuberculosis. Non-radiometric liquid culture system Mycobacterium Growth Indicator Tube with automated interface had been recommended by expert groups in addition to conventional solid culture media such as Lowenstein-Jensen. However in high burden resource limited countries advanced non-radiometric based tuberculosis diagnostic methods such as MGIT 960 is limited. Therefore we have evaluated the performance of MGIT 960 system compared to LJ for recovery of Mycobacterium complex (MTBC) from clinical specimens. A cross sectional study was conducted from a total of 908 samples between January 1st, 2013 to December 31st, 2014. Clinical specimens were processed following standard procedures and the final suspension was inoculated to MGIT tubes and LJ slant. Identification and confirmation of MTBC was done by ZN staining and SD Bioline test. Data was analyzed by SPSS version 20. The sensitivity, specificity, recovery rate and the average turnaround time to recover the organism was computed. From a total of 908 clinical specimens processed using both LJ and BACTEC MGIT liquid culture methods the recovery rate for LJ and MGIT, for smear positive samples was 66.7% (74/111) and 87.4% (97/ 111) respectively while for smear negative samples was 13.4% (108/797) and 17.4% (139/797) for LJ and MGIT methods respectively. The overall recovery rate for MGIT is significantly higher than LJ methods [26% (236/908; vs. 20%, 182/908, P = 0.002)]. The average turnaround time for smear positive samples was 16 and 31 days for MGIT and LJ respectively. Turnaround time for smear negative samples was 20 and 36 days for MGIT and LJ respectively. The overall agreement between MGIT and LJ was fairly good with Kappa value of 0.59 (P < 0.001). In the present study the contamination rate for MGIT is higher than the LJ methods, 15 and 9.3% respectively. The BACTEC MGIT liquid culture system has better MTBC recovery rate with shorter turnaround time for both smear positive and negative clinical specimens compared to Conventional LJ method. However, efforts should be made in order to reduce the high contamination rate in BACTEC MGIT system and to lesser extent to LJ methods.

  15. [Evaluation of the diagnostic performance of Xpert MTB/RIF test for the detection of Mycobacterium tuberculosis and rifampin resistance in clinical samples].

    PubMed

    Gürsoy, Nafia Canan; Yakupoğulları, Yusuf; Tekerekoğlu, Mehmet Sait; Otlu, Barış

    2016-04-01

    Rapid and accurate detection of active tuberculosis (TB) cases is one of the most important goal of tuberculosis control programme. For this purpose, new methods are being developed to isolate, serotype and determine the drug resistance of the agent. Xpert MTB/RIF test (CepheidGeneXpert® System, USA) that has been recently developed, is a real-time polymerase chain reaction-based method which detects Mycobacterium tuberculosis complex and resistance of the strain to rifampicin (RIF) from the clinical sample directly within a couple of hours. However, there are not sufficient data about the performance of that test for extrapulmonary samples and pulmonary samples other than sputum. The aims of this study were to investigate the sensitivity, specificity, positive and negative predictive values of Xpert MTB/RIF test in detection of M. tuberculosis and the performance in the determination of rifampicin resistance of the isolates from pulmonary and extrapulmonary clinical samples. A total of 2160 clinical samples, in which 1141 (52.8%) were pulmonary and 1019 (47.2%) were extrapulmonary samples, sent to our laboratory between July 2013 to December 2014, were included in the study. Sixty seven of the evaluated samples (3.1%) were positive with microscopy (acid-fast stain; AFS), 116 samples (5.1%) were positive with culture and 98 samples (4.5%) were positive with Xpert MTB/RIF test. When the culture was considered as the reference method, the sensitivity and specificity of Xpert MTB/RIF test were determined as 73.3% and 99.3%, respectively for all samples; 77.5% and 99.5%, respectively for pulmonary samples and 63.9% and 99.2%, respectively for extrapulmonary samples. Among AFS positive samples, the sensitivity was 100% and specificity was 66.7%; whereas among AFS negative samples those values were 40.4% and 99.4%, respectively. Among all the samples involved in the study, RIF resistance was determined only in three samples with Xpert MTB/ RIF test and that was also proved phenotypically (100% concordance). According to mycobacterial culture results, positive and negative predictive values of Xpert MTB/RIF test were determined as 86.7% and 98.5%, respectively for all samples. Those were determined as 92.5% and 98.3%, respectively for extrapulmonary samples and were determined as 74.2 and 98.7%, respectively for pulmonary samples. According to the results obtained in our study, sensitivity of Xpert MTB/RIF test for extrapulmonary samples was found to be at moderate level; sensitivity of the test was found to be decreased especially in AFS negative samples with less bacilli load. Nonetheless, specificity of Xpert MTB/RIF test to the agent in all samples was found to be extremely high. In our study, although RIF-resistant strains were detected in few of the samples, Xpert MTB/ RIF test could differentiate all resistant and sensitive strains. Additionally, detection of M. tuberculosis and RIF resistance in our laboratory takes approximately 20.96 days with culture, this period decreases to a couple of hours with Xpert MTB/RIF test. Because of the advantages such as being practical, rapid and requiring minimal safety measures, it was concluded that Xpert MTB/RIF test may contribute to rapid diagnosis of TB also in extrapulmonary samples, with the confirmation of culture method.

  16. The two faces of enhancing utilization of health-care services: determinants of patient initiation and retention in rural Burkina Faso.

    PubMed Central

    Mugisha, Frederick; Bocar, Kouyate; Dong, Hengjin; Chepng'eno, Gloria; Sauerborn, Rainer

    2004-01-01

    OBJECTIVE: To explore the factors that determine whether a patient will initiate treatment within a system of health-care services, and the factors that determine whether the patient will be retained in the chosen system, in Nouna, rural Burkina Faso. METHODS: The data used were pooled from four rounds of a household survey conducted in Nouna, rural Burkina Faso. The ongoing demographic surveillance system provided a sampling framework for this survey in which 800 households were sampled using a two-stage cluster sampling procedure. More than one treatment episode was observed for a single episode of illness per patient. The multinomial logit model was used to explore the determinants of patient initiation to systems of modern, traditional and home treatment, and a binary logit model was used to explore the determinants of patient retention within the chosen health-care provider system. FINDINGS: The results suggest that the determinants of patient initiation and their subsequent retention are different. Household income, education, urban residence and expected competency of the provider are positive predictors of initiation, but not of retention, for modern health-care services. Only perceived quality of care positively predicted retention in modern health-care services. CONCLUSION: Interventions focusing on patient initiation and patient retention are likely to be different. Policies directed at enhancing initiation for modern health-care services would primarily focus on reducing financial barriers, while those directed at increasing retention would primarily focus on attributes that improve the perceived quality of care. PMID:15375446

  17. Roughness sensor based on a compact optoelectronic emitter-receiver modules

    NASA Astrophysics Data System (ADS)

    Will, Matthias; Brodersen, Olaf; Steinke, Arndt

    2012-04-01

    In construction and manufacturing the surface roughness and their control plays a major role. The mechanical test probes are used in many applications, because the advantage of the higher resolution of optical systems often plays no role. But in all cases the measurement systems were uses outside of fabrication processes due to the complex and expensive equipment. To overcome these we developed a roughness sensor suitable for an automated control of machined surfaces. The sensor is able to handle high throughput and parallel systems is due to the low cost available. Our solution is compact stand-alone sensors that can be simple integrated in existing systems like machine tools or transport systems. The sensor is based on a diode laser, focusing optics and a special silicon photo diode array in a stable housing. The single-mode VCSEL at 670 nm emission wavelength is focused on the surface of the sample at distance of 5mm. The light was reflected from the test surface and detected with an 8-channel photodiode array. The position of the main reflex allows an optimization of the sensor distance to the surface. During the movement of the sample with a known velocity roughness depended signals over time were recorded at 8 cannels. This allows a detection of the angular distribution of the scattered light in combination of position dependent refection. It was shown here that we be able to achieve resolution below the spot diameter (30μm FWHM). We verify the sensor capabilities for real world applications on drilled samples with typical roughness variations in micro meter range.

  18. Use of multiple picosecond high-mass molecular dynamics simulations to predict crystallographic B-factors of folded globular proteins.

    PubMed

    Pang, Yuan-Ping

    2016-09-01

    Predicting crystallographic B-factors of a protein from a conventional molecular dynamics simulation is challenging, in part because the B-factors calculated through sampling the atomic positional fluctuations in a picosecond molecular dynamics simulation are unreliable, and the sampling of a longer simulation yields overly large root mean square deviations between calculated and experimental B-factors. This article reports improved B-factor prediction achieved by sampling the atomic positional fluctuations in multiple picosecond molecular dynamics simulations that use uniformly increased atomic masses by 100-fold to increase time resolution. Using the third immunoglobulin-binding domain of protein G, bovine pancreatic trypsin inhibitor, ubiquitin, and lysozyme as model systems, the B-factor root mean square deviations (mean ± standard error) of these proteins were 3.1 ± 0.2-9 ± 1 Å 2 for Cα and 7.3 ± 0.9-9.6 ± 0.2 Å 2 for Cγ, when the sampling was done for each of these proteins over 20 distinct, independent, and 50-picosecond high-mass molecular dynamics simulations with AMBER forcefield FF12MC or FF14SB. These results suggest that sampling the atomic positional fluctuations in multiple picosecond high-mass molecular dynamics simulations may be conducive to a priori prediction of crystallographic B-factors of a folded globular protein.

  19. Process observation in fiber laser-based selective laser melting

    NASA Astrophysics Data System (ADS)

    Thombansen, Ulrich; Gatej, Alexander; Pereira, Milton

    2015-01-01

    The process observation in selective laser melting (SLM) focuses on observing the interaction point where the powder is processed. To provide process relevant information, signals have to be acquired that are resolved in both time and space. Especially in high-power SLM, where more than 1 kW of laser power is used, processing speeds of several meters per second are required for a high-quality processing results. Therefore, an implementation of a suitable process observation system has to acquire a large amount of spatially resolved data at low sampling speeds or it has to restrict the acquisition to a predefined area at a high sampling speed. In any case, it is vitally important to synchronously record the laser beam position and the acquired signal. This is a prerequisite that allows the recorded data become information. Today, most SLM systems employ f-theta lenses to focus the processing laser beam onto the powder bed. This report describes the drawbacks that result for process observation and suggests a variable retro-focus system which solves these issues. The beam quality of fiber lasers delivers the processing laser beam to the powder bed at relevant focus diameters, which is a key prerequisite for this solution to be viable. The optical train we present here couples the processing laser beam and the process observation coaxially, ensuring consistent alignment of interaction zone and observed area. With respect to signal processing, we have developed a solution that synchronously acquires signals from a pyrometer and the position of the laser beam by sampling the data with a field programmable gate array. The relevance of the acquired signals has been validated by the scanning of a sample filament. Experiments with grooved samples show a correlation between different powder thicknesses and the acquired signals at relevant processing parameters. This basic work takes a first step toward self-optimization of the manufacturing process in SLM. It enables the addition of cognitive functions to the manufacturing system to the extent that the system could track its own process. The results are based on analyzing and redesigning the optical train, in combination with a real-time signal acquisition system which provides a solution to certain technological barriers.

  20. [Water quality and microbiological status of the distribution system: traditional parameters and emerging parameters].

    PubMed

    Scoglio, M E; Grillo, O C; Munaò, F; Di Pietro, A; Squeri, L

    1989-01-01

    Most pollution of drinking water is caused by inadequacy of the uptake and distribution systems, by insufficient upkeep of the sewage system and by defects or breaks in the disinfection processes. This may be the cause of waterborne epidemic outbreaks and therefore it is necessary carry out routine controls by simple and rapid tests for the detection of intestinal organisms. In the light of minor hepatitis A epidemics occurred in the town of Messina, we have carried out a study to determine the drinking water quality. To this end, in addition to the traditional tests recommended by CEE and required by the 8/2/1985 DPCM (37 degrees C and 20 degrees C viable count, total and faecal coliforms and faecal streptococci), we have carried out P. aeruginosa, coliphages and gram-negative endotoxins tests, in 74 water samples drawn on way in and way out of the tanks and along the piping system. Only 12.5% of the sixteen water samples drawn on way in (before disinfection system) was in compliance with the law. 75% of these samples showed positivity for faecal streptococci. The water quality was lower in the fourteen water samples drawn on way out of the tanks (7.1% was in compliance with the law). The percent of positivity along the piping system for total and faecal coliforms and for faecal streptococci was 34.1, 15.9 and 59.1 respectively. Coliphages were always absent. P. aeruginosa was almost always present in way in water (93.7%). Moreover this microorganism was recovered in 85.7% of the samples drawn on the way out and in 77.3% along the piping system. In the same drawing places endotoxins were present at high percentage (100%, 85.7% and 90.9%). These values come from high test sensitivity and poor water quality. Finally we have pointed out the importance of all the parameters examined. The significance of coliform bacteria is known, but we consider very important, as organisms indicative of pollution, the enterococci, since they P. aeruginosa may survive long time in fresh water though it is not autoctone, but, in general, of faecal origin. Several soluble antigens of this microorganism as well as enterococci show positive LAL tests (1-5-6). The endotoxin content in fresh water reflects the degree of bacterial contamination. We believe, therefore, it is needed to fix an upper limit to endotoxins in drinking water. Coliphages concentrations could be correlated with enteric virus concentrations but the ratio of coliforms to coliphages is about 100:1. Therefore this indicator of viral pollution is helpful only for highly polluted surface waters.

  1. Vibrational Properties of High- Superconductors Levitated Above a Bipolar Permanent Magnetic Guideway

    NASA Astrophysics Data System (ADS)

    Liu, Lu; Wang, Jiasu

    2014-05-01

    A bipolar permanent magnetic guideway (PMG) has a unique magnetic field distribution profile which may introduce a better levitation performance and stability to the high- superconducting (HTS) maglev system. The dynamic vibration properties of multiple YBCO bulks arranged into different arrays positioned above a bipolar PMG and free to levitate were investigated. The acceleration and resonance frequencies were experimentally measured, and the stiffness and damping coefficients were evaluated for dynamic stability. Results indicate that the levitation stiffness is closely related to the field-cooling-height and sample positioning. The damping ratio was found to be low and nonlinear for the Halbach bipolar HTS-PMG system.

  2. Human herpesvirus infections of the central nervous system: laboratory diagnosis based on DNA detection by nested PCR in plasma and cerebrospinal fluid samples.

    PubMed

    Rimério, Carla Aparecida Tavares; De Oliveira, Renato Souza; de Almeida Bonatelli, Murilo Queiroz; Nucci, Anamarli; Costa, Sandra Cecília Botelho; Bonon, Sandra Helena Alves

    2015-04-01

    Infections of the central nervous systems (CNS) present a diagnostic problem for which an accurate laboratory diagnosis is essential. Invasive practices, such as cerebral biopsy, have been replaced by obtaining a polymerase chain reaction (PCR) diagnosis using cerebral spinal fluid (CSF) as a reference method. Tests on DNA extracted from plasma are noninvasive, thus avoiding all of the collateral effects and patient risks associated with CSF collection. This study aimed to determine whether plasma can replace CSF in nested PCR analysis for the detection of CNS human herpesvirus (HHV) diseases by analysing the proportion of patients whose CSF nested PCR results were positive for CNS HHV who also had the same organism identified by plasma nested PCR. In this study, CSF DNA was used as the "gold standard," and nested PCR was performed on both types of samples. Fifty-two patients with symptoms of nervous system infection were submitted to CSF and blood collection. For the eight HHV, one positive DNA result-in plasma and/or CSF nested PCR-was considered an active HHV infection, whereas the occurrence of two or more HHVs in the same sample was considered a coinfection. HHV infections were positively detected in 27/52 (51.9%) of the CSF and in 32/52 (61.5%) of the plasma, difference not significant, thus nested PCR can be performed on plasma instead of CSF. In conclusion, this findings suggest that plasma as a useful material for the diagnosis of cases where there is any difficulty to perform a CSF puncture. © 2015 Wiley Periodicals, Inc.

  3. Evaluation of the Hologic gen-probe PANTHER, APTIMA Combo 2 assay in a tertiary care teaching hospital.

    PubMed

    Cheng, Annie; Kirby, James E

    2014-03-01

    To evaluate the performance of the Hologic Gen-Probe (San Diego, CA) PANTHER system. The performance of PANTHER was compared with the Hologic Gen-Probe TIGRIS and/or Roche (Indianapolis, IN) COBAS AMPLICOR systems through testing of patient specimens and the spiked-urine matrix. After discrepant resolution, PANTHER demonstrated a 99.3% (95% confidence interval [CI], 96.0%-99.9%) positive and 100% (98.5%-100.0%) negative agreement for Chlamydia trachomatis (CT) and 100% (96.6%-100.0%) positive and 100% (98.6%-100.0%) negative agreement for Neisseria gonorrhoeae (NG) for all male, female, unsexed, and NG-spiked female urine specimens combined. For other specimen types collectively, the PANTHER demonstrated 100% (95% CI, 90.6%-100.0%) positive and 100% (88.3%-100.0%) negative agreement for CT and 90.9% (62.8%-98.4%) positive and 100% (93.5%-100.0%) negative agreement for NG. Analytical sensitivity of the PANTHER in urine matrix was similar to the TIGRIS system. The PANTHER system provides an excellent new addition to options for detecting CT and NG, is appropriate for testing urine samples, and will facilitate high-throughput testing in the clinical laboratory.

  4. Plant Rhizosphere Selection of Plasmodiophorid Lineages from Bulk Soil: The Importance of “Hidden” Diversity

    PubMed Central

    Bass, David; van der Gast, Christopher; Thomson, Serena; Neuhauser, Sigrid; Hilton, Sally; Bending, Gary D.

    2018-01-01

    Microbial communities closely associated with the rhizosphere can have strong positive and negative impacts on plant health and growth. We used a group-specific amplicon approach to investigate local scale drivers in the diversity and distribution of plasmodiophorids in rhizosphere/root and bulk soil samples from oilseed rape (OSR) and wheat agri-systems. Plasmodiophorids are plant- and stramenopile-associated protists including well known plant pathogens as well as symptomless endobiotic species. We detected 28 plasmodiophorid lineages (OTUs), many of them novel, and showed that plasmodiophorid communities were highly dissimilar and significantly divergent between wheat and OSR rhizospheres and between rhizosphere and bulk soil samples. Bulk soil communities were not significantly different between OSR and wheat systems. Wheat and OSR rhizospheres selected for different plasmodiophorid lineages. An OTU corresponding to Spongospora nasturtii was positively selected in the OSR rhizosphere, as were two genetically distinct OTUs. Two novel lineages related to Sorosphaerula veronicae were significantly associated with wheat rhizosphere samples, indicating unknown plant-protist relationships. We show that group-targeted eDNA approaches to microbial symbiont-host ecology reveal significant novel diversity and enable inference of differential activity and potential interactions between sequence types, as well as their presence. PMID:29503632

  5. Occurrence and characterization of Campylobacter in the Brazilian production and processing of broilers.

    PubMed

    Kuana, S L; Santos, L R; Rodrigues, L B; Borsoi, A; Moraes, H L S; Salle, C T P; Nascimento, V P

    2008-12-01

    Twenty-two commercial broiler flocks and their carcasses, totaling 546 samples (450 collected from a poultry farm and 96 from a slaughterhouse), were surveyed for the presence of Campylobacter. The positive results for Campylobacter among the analyzed samples were homogeneous, yielding 81.8% for cecal droppings, 80.9% for feces, and 80.4% for cloacal swabs. Pre-enrichment and direct plating showed that 77.85% and 81.8% of cloacal swabs, respectively, were positive for Campylobacter compared to 99.0% and 97.9% of carcasses testing positive with the pre-enrichment and direct plating methods. The Campylobacter count averaged 7.0 log10 colony-forming units (CFU)/g in cecal droppings, 5.15 log10 CFU/carcass after defeathering, and 4.24 log10 CFU/carcass after chilling. The samples were identified by the API Campy system as Campylobacter jejuni subsp. jejuni (68.8%), Campylobacter coli (8.3%), Campylobacter jejuni subsp. doylei (6.3%), Campylobacter upsaliensis (4.2%), and Campylobacter fetus subsp. fetus (2.1%). The analyzed broiler flocks were positive for Campylobacter in 81.8% of the cases, thus characterizing the occurrence of this pathogen in a broiler-producing region in southern Brazil. These results highlight the importance of programs targeted at the reduction of Campylobacter in poultry products, in order to minimize the risks for consumers.

  6. Natural stable isotopic compositions of mercury in aerosols and wet precipitations around a coal-fired power plant in Xiamen, southeast China

    NASA Astrophysics Data System (ADS)

    Huang, Shuyuan; Sun, Lumin; Zhou, Tingjin; Yuan, Dongxing; Du, Bing; Sun, Xiuwu

    2018-01-01

    In this study, samples of 18 wet precipitations (WPs) and 38 aerosols were collected around a coal-fired power plant (CFPP) located in Xiamen, southeast China, which was equipped with a seawater flue gas desulfurization system. Total particulate mercury (TPM) in aerosol samples, and total mercury (WP-TM), dissolved mercury (WP-DM) and particulate mercury (WP-PM) in WP samples were analyzed for the natural isotopic compositions of mercury. For the first time, both mass dependent fractionation (MDF) and mass independent fractionation of odd (odd-MIF) and even (even-MIF) isotopes of WP-DM and WP-PM were reported and discussed. Both WP-TM and TPM displayed negative MDF and slightly positive even-MIF. Negative odd-MIF was observed in TPM and WP-PM, whereas positive odd-MIF was observed in WP-TM and WP-DM. It was found that the mercury budget in WP-PM samples was mainly controlled by atmospheric particles. Potential sources of mercury in samples were identified via analysis of mercury isotopic signatures and meteorological data with the NOAA HYSPLIT model. The results showed that TPM and WP-PM in solid samples were homologous and the isotopic compositions of WP-TM depended on those of WP-DM. The ratios of Δ199Hg/Δ201Hg resulting from photochemical reactions and positive Δ200Hg values (from -0.06‰ to 0.27‰) in all samples indicated that the mercury coming from local emission of the CFPP together with long-distance transportation were the two main contributing sources.

  7. Immunoglobulin G4-positive lymphoplasmacytic infiltration in a sarcoidal eyelid mass.

    PubMed

    Kang, Hyera; Takahashi, Yasuhiro; Takahashi, Emiko; Kakizaki, Hirohiko

    2018-05-01

    A 62-year-old woman presented with a one month history of a hard, nonmobile subcutaneous mass along the right nasojugal fold. Hematological studies showed elevated serum immunoglobulin G4 levels. Histopathological examination of the biopsy sample disclosed immunoglobulin G4-positive lymphoplasmacytic infiltration with a storiform fibrosis, vein occlusion, and epithelioid granulomas with necrosis. Systemic review corresponded to a sarcoidosis. Without treatment, the eyelid mass did not recur six months after the excisional biopsy.

  8. Deterministic control of the emission from light sources in 1D nanoporous photonic crystals (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Galisteo-López, Juan F.

    2017-02-01

    Controlling the emission of a light source demands acting on its local photonic environment via the local density of states (LDOS). Approaches to exert such control on large scale samples, commonly relying on self-assembly methods, usually lack from a precise positioning of the emitter within the material. Alternatively expensive and time consuming techniques can be used to produce samples of small dimensions where a deterministic control on emitter position can be achieved. In this work we present a full solution process approach to fabricate photonic architectures containing nano-emitters which position can be controlled with nanometer precision over squared milimiter regions. By a combination of spin and dip coating we fabricate one-dimensional (1D) nanoporous photonic crystals, which potential in different fields such as photovoltaics or sensing has been previously reported, containing monolayers of luminescent polymeric nanospheres. We demonstrate how, by modifying the position of the emitters within the photonic crystal, their emission properties (photoluminescence intensity and angular distribution) can be deterministically modified. Further, the nano-emitters can be used as a probe to study the LDOS distribution within these systems with a spatial resolution of 25 nm (provided by the probe size) carrying out macroscopic measurements over squared milimiter regions. Routes to enhance light-matter interaction in this kind of systems by combining them with metallic surfaces are finally discussed.

  9. Evaluation of commercially prepared transport systems for nonlethal detection of Aeromonas salmonicida in salmonid fish

    USGS Publications Warehouse

    Cipriano, R.C.; Bullock, G.L.

    2001-01-01

    In vitro studies indicated that commercially prepared transport systems containing Amies, Stuart's, and Cary-Blair media worked equally well in sustaining the viability of the fish pathogen Aeromonas salmonicida, which causes furunculosis. The bacterium remained viable without significant increase or decrease in cell numbers for as long as 48 h of incubation at 18-20??C in Stuart's transport medium; consequently, obtaining mucus samples in such tubes were comparable to on-site detection of A. salmonicida by dilution plate counts on Coomassie Brilliant Blue agar. In three different assays of 100 samples of mucus from Atlantic salmon Salmo salar infected subclinically with A. salmonicida, dilution counts conducted on-site proved more reliable for detecting the pathogen than obtaining the samples in the transport system. In the on-site assays, dilution counts detected the pathogen in 34, 41, and 22 samples, whereas this was accomplished in only 15, 15, and 3 of the respective samples when the transport system was used. In an additional experiment, Arctic char Salvelinus alpinus sustaining a frank epizootic of furunculosis were sampled similarly. Here, too, dilution counts were more predictive of the prevalence of A. salmonicida and detected the pathogen in 46 mucus samples; in comparison, only 6 samples collected by using the transport system were positive. We also observed that the transport system supported the growth of the normal mucus bacterial flora. Particularly predominant among these were motile aeromonads and Pseudomonas fluorescens. In studies of mixed culture growth, two representatives of both of the latter genera of bacteria outgrew A. salmonicida - in some cases, to the total exclusion of the pathogen itself.

  10. Arrayed Micro-Ring Spectrometer System and Method of Use

    NASA Technical Reports Server (NTRS)

    Choi, Sang H. (Inventor); Park, Yeonjoon (Inventor); King, Glen C. (Inventor); Elliott, James R. (Inventor)

    2012-01-01

    A spectrometer system includes an array of micro-zone plates (MZP) each having coaxially-aligned ring gratings, a sample plate for supporting and illuminating a sample, and an array of photon detectors for measuring a spectral characteristic of the predetermined wavelength. The sample plate emits an evanescent wave in response to incident light, which excites molecules of the sample to thereby cause an emission of secondary photons. A method of detecting the intensity of a selected wavelength of incident light includes directing the incident light onto an array of MZP, diffracting a selected wavelength of the incident light onto a target focal point using the array of MZP, and detecting the intensity of the selected portion using an array of photon detectors. An electro-optic layer positioned adjacent to the array of MZP may be excited via an applied voltage to select the wavelength of the incident light.

  11. Application of an ultrasonic focusing radiator for acoustic levitation of submillimeter samples

    NASA Technical Reports Server (NTRS)

    Lee, M. C.

    1981-01-01

    An acoustic apparatus has been specifically developed to handle samples of submillimeter size in a gaseous medium. This apparatus consists of an acoustic levitation device, deployment devices for small liquid and solid samples, heat sources for sample heat treatment, acoustic alignment devices, a cooling system and data-acquisition instrumentation. The levitation device includes a spherical aluminum dish of 12 in. diameter and 0.6 in. thickness, 130 pieces of PZT transducers attached to the back side of the dish and a spherical concave reflector situated in the vicinity of the center of curvature of the dish. The three lowest operating frequencies for the focusing-radiator levitation device are 75, 105 and 163 kHz, respectively. In comparison with other levitation apparatus, it possesses a large radiation pressure and a high lateral positional stability. This apparatus can be used most advantageously in the study of droplets and spherical shell systems, for instance, for fusion target applications.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Berkel, Gary J.

    A system for sampling a sample material includes a probe which can have an outer probe housing with an open end. A liquid supply conduit within the housing has an outlet positioned to deliver liquid to the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust conduit within the housing is provided for removing liquid from the open end of the housing. A liquid exhaust system can be provided for removing liquid from themore » liquid exhaust conduit at a second volumetric flow rate, the first volumetric flow rate exceeding the second volumetric flow rate, wherein liquid at the open end will receive sample, liquid containing sample material will be drawn into and through the liquid exhaust conduit, and liquid will overflow from the open end.« less

  13. Machine Learning Toolkit for Extreme Scale

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2014-03-31

    Support Vector Machines (SVM) is a popular machine learning technique, which has been applied to a wide range of domains such as science, finance, and social networks for supervised learning. MaTEx undertakes the challenge of designing a scalable parallel SVM training algorithm for large scale systems, which includes commodity multi-core machines, tightly connected supercomputers and cloud computing systems. Several techniques are proposed for improved speed and memory space usage including adaptive and aggressive elimination of samples for faster convergence , and sparse format representation of data samples. Several heuristics for earliest possible to lazy elimination of non-contributing samples are consideredmore » in MaTEx. In many cases, where an early sample elimination might result in a false positive, low overhead mechanisms for reconstruction of key data structures are proposed. The proposed algorithm and heuristics are implemented and evaluated on various publicly available datasets« less

  14. Comparison of culture and biochemical tests with PCR for detection of Brachyspira hyodysenteriae and Brachyspira pilosicoli.

    PubMed

    Råsbäck, T; Fellström, C; Gunnarsson, A; Aspán, A

    2006-08-01

    Traditional culture and biochemical tests (CBT) were compared with PCR for sensitivity and detection of Brachyspira hyodysenteriae and Brachyspira pilosicoli in seeded faeces and clinical samples from diarrhoeic pigs. A duplex PCR system was developed based on primers detecting the tlyA-gene of B. hyodysenteriae and the 16S rRNA-gene of B. pilosicoli. Sensitivities for the PCR system were determined on seeded faeces, using DNA that had been recovered from primary cultures or extracted directly from faeces. Compared to CBT, PCR applied to DNA extracted directly from faeces lowered the sensitivity by a factor of 1000 to 10,000. B. hyodysenteriae and B. pilosicoli detection was compared for CBT and PCR using 200 clinical samples. CBT detected more B. hyodysenteriae isolates in the clinical samples than PCR, but fewer B. pilosicoli positive samples. An atypical strongly haemolytic isolate was detected only by CBT.

  15. One-step cross-genogroup multiplex RT-qPCR with an internal control system for the detection of infectious pancreatic necrosis virus (IPNV).

    PubMed

    Hoferer, Marc; Braun, Anne; Skrypski, Julia; Bock, Sabine; Thalheim, Sabine; Sting, Reinhard

    2017-09-01

    Infectious pancreatic necrosis virus (IPNV) causes great losses in fish hatcheries world-wide. The detection of IPNV can be challenging in certain circumstances, particularly due to low viral load and the genetic variability of this RNA virus. For the first time, this project created a quantitative triplex real-time reverse transcription PCR (RT-qPCR), including an endogenous control system, for specific, sensitive and rapid detection of IPNV in routine diagnostics. Multiple sequence alignment of 46 nucleotide sequences of the segment A genome obtained from the NCBI database allowed the design of two RT-qPCR systems covering the IPNV genogroup 1 and genogroups 2-5, respectively. The completed triplex RT-qPCR including a salmonid-specific endogenous control showed high specificity and an analytical sensitivity of 20-40 oligonucleotide copies. Testing of dilution series of virus-loaded cell culture suspensions proved equality of the triplex RT-qPCR with virus detection in cell culture and a higher sensitivity than conventional RT-PCR in field samples. In comparative studies of a total of 77 field samples tested, 51 showed identical positive and 19 identical negative results in cell culture and the triplex RT-qPCR. However, seven other samples yielded positive results in the triplex RT-qPCR, but negative results in cell culture. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Hepatitis C Testing

    PubMed Central

    Rochlani, Maya; Lewis, Jessica H.; Ramsey, Glenn E.; Bontempo, Franklin A.; Shah, Gunjan; Bowman, Rebecca A.; van Thiel, David H.; Starzl, Thomas E.

    2010-01-01

    Plasma samples from 1,182 patients undergoing primary liver transplantation were tested for anti-hepatitis C (HCV) virus by two methods: Ortho HCV ELISA Test System (EIA) and Chiron RIBA HCV Test System (RIBA II). The EIA results, 0 or +, were recorded first, followed by RIBA results, N = negative, P = positive, or I = indeterminate. Concordant results—0N, + P, + I—were found in 1,076 (91%), and discordant results were found in 106 (9%). The EIA optical density did not relate to concordant or discordant results. Band patterns were described by stating the band position (1, 2, 3, or 4) and insetting a dash (−) if no band was visualized. Most + P samples fell into two patterns: 47% showed all four bands, pattern 1234, and 15% showed the two-band pattern, 34. When the EIA was negative, 0P, the opposite was seen: 8% showed the 1234 pattern and 81% showed the 34 pattern. There were 226 samples that formed bands (+ P, 149; 0P, 31; + I, 15; 0I, 31). The frequency of bands was as follows: 4, 32%; 3, 31%; 2, 19%; and 1, 18%. Band 2 and the EIA test detected antibodies to the same c100-3 fragment and showed 74% concordance. No explanation is apparent for the lower concordance rate here than that between the EIA test and bands 3 = 96% or 4 = 88%. The EIA and RIBA II tests, together with positive liver function tests and abnormal tissue pathologic findings, provide a basis for the diagnosis of HCV. PMID:1377442

  17. Acoustic forcing of a liquid drop

    NASA Technical Reports Server (NTRS)

    Lyell, M. J.

    1992-01-01

    The development of systems such as acoustic levitation chambers will allow for the positioning and manipulation of material samples (drops) in a microgravity environment. This provides the capability for fundamental studies in droplet dynamics as well as containerless processing work. Such systems use acoustic radiation pressure forces to position or to further manipulate (e.g., oscillate) the sample. The primary objective was to determine the effect of a viscous acoustic field/tangential radiation pressure forcing on drop oscillations. To this end, the viscous acoustic field is determined. Modified (forced) hydrodynamic field equations which result from a consistent perturbation expansion scheme are solved. This is done in the separate cases of an unmodulated and a modulated acoustic field. The effect of the tangential radiation stress on the hydrodynamic field (drop oscillations) is found to manifest as a correction to the velocity field in a sublayer region near the drop/host interface. Moreover, the forcing due to the radiation pressure vector at the interface is modified by inclusion of tangential stresses.

  18. Directional emittance surface measurement system and process

    NASA Technical Reports Server (NTRS)

    Puram, Chith K. (Inventor); Daryabeigi, Kamran (Inventor); Wright, Robert (Inventor); Alderfer, David W. (Inventor)

    1994-01-01

    Apparatus and process for measuring the variation of directional emittance of surfaces at various temperatures using a radiometric infrared imaging system. A surface test sample is coated onto a copper target plate provided with selective heating within the desired incremental temperature range to be tested and positioned onto a precision rotator to present selected inclination angles of the sample relative to the fixed positioned and optically aligned infrared imager. A thermal insulator holder maintains the target plate on the precision rotator. A screen display of the temperature obtained by the infrared imager, and inclination readings are provided with computer calculations of directional emittance being performed automatically according to equations provided to convert selected incremental target temperatures and inclination angles to relative target directional emittance values. The directional emittance of flat black lacquer and an epoxy resin measurements obtained are in agreement with the predictions of the electromagnetic theory and with directional emittance data inferred from directional reflectance measurements made on a spectrophotometer.

  19. SELDI-TOF-MS proteomic profiling of serum, urine, and amniotic fluid in neural tube defects.

    PubMed

    Liu, Zhenjiang; Yuan, Zhengwei; Zhao, Qun

    2014-01-01

    Neural tube defects (NTDs) are common birth defects, whose specific biomarkers are needed. The purpose of this pilot study is to determine whether protein profiling in NTD-mothers differ from normal controls using SELDI-TOF-MS. ProteinChip Biomarker System was used to evaluate 82 maternal serum samples, 78 urine samples and 76 amniotic fluid samples. The validity of classification tree was then challenged with a blind test set including another 20 NTD-mothers and 18 controls in serum samples, and another 19 NTD-mothers and 17 controls in urine samples, and another 20 NTD-mothers and 17 controls in amniotic fluid samples. Eight proteins detected in serum samples were up-regulated and four proteins were down-regulated in the NTD group. Four proteins detected in urine samples were up-regulated and one protein was down-regulated in the NTD group. Six proteins detected in amniotic fluid samples were up-regulated and one protein was down-regulated in the NTD group. The classification tree for serum samples separated NTDs from healthy individuals, achieving a sensitivity of 91% and a specificity of 97% in the training set, and achieving a sensitivity of 90% and a specificity of 97% and a positive predictive value of 95% in the test set. The classification tree for urine samples separated NTDs from controls, achieving a sensitivity of 95% and a specificity of 94% in the training set, and achieving a sensitivity of 89% and a specificity of 82% and a positive predictive value of 85% in the test set. The classification tree for amniotic fluid samples separated NTDs from controls, achieving a sensitivity of 93% and a specificity of 89% in the training set, and achieving a sensitivity of 90% and a specificity of 88% and a positive predictive value of 90% in the test set. These suggest that SELDI-TOF-MS is an additional method for NTDs pregnancies detection.

  20. Efficacy of the detection of Legionella in hot and cold water samples by culture and PCR. II. Examination of native samples from various sources.

    PubMed

    Stojek, Nimfa Maria; Wójcik-Fatla, Angelina; Dutkiewicz, Jacek

    2012-01-01

    A total of 123 water samples were examined in parallel by culture and semi-nested PCR for the presence of Legionella. They comprised: 35 samples of hot water distributed by the urban municipal water supply system (MWSS) taken in institutions, 45 samples of hot water distributed by urban MWSS taken in dwellings, 27 samples of cold water distributed by rural MWSS taken in dwellings, and 16 samples of cold well water taken in rural areas. The greatest frequency of the isolation of Legionella by culture (88.6%) was recorded in the samples of hot water from the urban institutions, having been greater compared to all other sources (p<0.001). The frequency of Legionella isolation from hot water in urban dwellings (28.9%) was significantly greater compared to the combined value (2.3%) for cold water from rural MWSS and wells (p<0.001). Strains belonging to Legionella pneumophila serogroups 2-14 predominated in the examined samples, while strains of L. pneumophila serogroup 1 and strains of Legionella spp. (other than L. pneumophila) were 3-fold less numerous. The rates of positive findings in the semi-nested PCR (stage 2) were greater than culture isolations in all kinds of samples, except for urban institutions. The correlation between the culture and PCR results was positive for samples of hot water from urban MWSS (p<0.01), but not for samples of cold water from rural MWSS and wells (p>0.5). A significant correlation was found between rates of PCR-positive results and numbers of Legionella pneumophila serogroups 2-14 strains, but not for other Legionella serogroups or species. In conclusion, our results support the opinion that though PCR cannot be a substitute for the isolation of Legionella by culture, it could be regarded as an useful complementary method.

  1. Evaluation of the hyplex® TBC PCR test for detection of Mycobacterium tuberculosis complex in clinical samples

    PubMed Central

    2010-01-01

    Background Tuberculosis (TB) is one of the major public health concerns worldwide. The detection of the pathogen Mycobacterium tuberculosis complex (MTBC) as early as possible has a great impact on the effective control of the spread of the disease. In our study, we evaluated the hyplex® TBC PCR test (BAG Health Care GmbH), a novel assay using a nucleic acid amplification technique (NAAT) with reverse hybridisation and ELISA read out for the rapid detection of M. tuberculosis directly in clinical samples. Results A total of 581 respiratory and non-respiratory specimens from our pneumological hospital and the National TB Institute of Uzbekistan were used for the evaluation of the PCR assay. Of these, 292 were classified as TB samples and 289 as non-TB samples based on the results of the TB cultures as reference method. The PCR results were initially used to optimise the cut-off value of the hyplex® TBC test system by means of a ROC analysis. The overall sensitivity of the assay was determined to be 83.1%. In smear-positive TB samples, the sensitivity of the hyplex® TBC PCR test was estimated to 93.4% versus 45.1% in smear-negative samples. The specificity of the test was 99.25%. Of the two specimens (0.75%) with false-positive PCR results, one yielded a culture positive for non-tuberculous mycobacteria. Based on the assumption of a prevalence of 8% TB positives among the samples in our diagnostic TB laboratory, the positive and negative predictive values were estimated to 90.4% and 98.5%, respectively. Conclusions The hyplex® TBC PCR test is an accurate NAAT assay for a rapid and reliable detection of M. tuberculosis in various respiratory and non-respiratory specimens. Compared to many other conventional NAAT assays, the hyplex® TBC PCR test is in a low price segment which makes it an attractive option for developing and emerging countries with high TB burdens. PMID:20356361

  2. Comparison between Indirect Immunofluorescence Assay and Shell Vial Culture for Detection of Mumps Virus from Clinical Samples

    PubMed Central

    Reina, Jordi; Ballesteros, Francisca; Ruiz de Gopegui, Enrique; Munar, Maria; Mari, Margarita

    2003-01-01

    We report a prospective comparison of the efficacies of an indirect immunofluorescence assay (IFA) and shell vial culture (SVC) of throat swab and urine samples from patients with mumps. Throat swab samples were used for the IFA; the urine samples and throat swabs were inoculated into vials of Vero cells. We studied 62 patients by using 62 throat swabs and 50 urine samples (50 patients with both samples). Sixty (96.7%) throat samples were positive in the SVC, and 61 (98.3%) were positive in the IFA. For the 50 patients from whom both samples were available, the IFA was positive in 50 (100%) cases, the urine sample was positive in 49 (98%) cases, and the throat swab was positive in 48 (96%) cases (P > 0.05). This comparison of throat swabs and urine samples has shown that the two clinical samples are similar in efficacy. PMID:14605158

  3. Raman technology for future planetary missions

    NASA Astrophysics Data System (ADS)

    Thiele, Hans; Hofer, Stefan; Stuffler, Timo; Glier, Markus; Popp, Jürgen; Sqalli, Omar; Wuttig, Andreas; Riesenberg, Rainer

    2017-11-01

    Scientific experiments on mineral and biological samples with Raman excitation below 300nm show a wealth of scientific information. The fluorescence, which typically decreases signal quality in the visual or near infrared wavelength regime can be avoided with deep ultraviolet excitation. This wavelength regime is therefore regarded as highly attractive for a compact high performance Raman spectrometer for in-situ planetary research. Main objective of the MIRAS II breadboard activity presented here (MIRAS: Mineral Investigation with Raman Spectroscopy) is to evaluate, design and build a compact fiber coupled deep-UV Raman system breadboard. Additionally, the Raman system is combined with an innovative scanning microscope system to allow effective auto-focusing and autonomous orientation on the sample surface for high precise positioning or high resolution Raman mapping.

  4. Anti-nuclear autoantibodies in the general German population: prevalence and lack of association with selected cardiovascular and metabolic disorders-findings of a multicenter population-based study.

    PubMed

    Akmatov, Manas K; Röber, Nadja; Ahrens, Wolfgang; Flesch-Janys, Dieter; Fricke, Julia; Greiser, Halina; Günther, Kathrin; Kaaks, Rudolf; Kemmling, Yvonne; Krone, Bastian; Linseisen, Jakob; Meisinger, Christa; Moebus, Susanne; Obi, Nadia; Guzman, Carlos A; Conrad, Karsten; Pessler, Frank

    2017-06-06

    We determined the prevalence of anti-nuclear autoantibodies (ANAs) in the German adult population and examined the association between ANAs and cardiovascular and metabolic disorders. We used data and blood samples from the pretest phases of the German National Cohort, obtained from six of the 18 study centers (n = 1199). All centers applied standardized instruments including face-to-face interviews, anthropometric measurements and collection of blood samples. Self-reported histories of diabetes mellitus, heart attack and elevated blood cholesterol and/or lipids were recorded. Height, weight and blood pressure were measured. ANAs were detected using a semi-automated system (AKLIDES®; Medipan GmbH, Dahlewitz, Germany). A positive ANA was defined as a titer ≥ 1:80. ANA were classified as weakly (1:80 or 1:160), moderately (1:320 or 1:640) or strongly (≥1:1280) positive. Specific autoantibodies against nuclear antigens were detected with second-step assays according to the ANA staining pattern. Associations between the assessed disorders and ANA positivity and pattern were examined using sex and age-adjusted mixed-effects logistic regression models. Thirty-three percent (95% confidence interval; 31-36%) of the 1196 participants (measurements could not be obtained from three samples) were ANA positive (titer ≥ 1:80). The proportions of weakly, moderately and strongly positive ANA were 29%, 3.3% and 1.3%, respectively. ANA positivity was more common among women than men across all titers (χ 2 , p = 0.03). ANA positivity, even when stratified according to height of titer or immunofluorescent pattern, was not associated with diabetes, elevated blood cholesterol and/or lipids, obesity or hypertension. Second-step autoantibody assays were positive in 41 of the 83 samples (49%) tested, with anti-DFS70 (n = 13) and anti-dsDNA (n = 7) being most frequent. These subgroups were too small to test for associations with the disorders assessed. The prevalence of ANA positivity in the German general population was similar to values reported from other countries. Contrary to other studies, there was no association with selected self-reported and objectively measured cardiovascular and metabolic variables.

  5. An automated single ion hit at JAERI heavy ion microbeam to observe individual radiation damage

    NASA Astrophysics Data System (ADS)

    Kamiya, Tomihiro; Sakai, Takuro; Naitoh, Yutaka; Hamano, Tsuyoshi; Hirao, Toshio

    1999-10-01

    Microbeam scanning and a single ion hit technique have been combined to establish an automated beam positioning and single ion hit system at the JAERI Takasaki heavy ion microbeam system. Single ion irradiation on preset points of a sample in various patterns can be performed automatically in a short period. The reliability of the system was demonstrated using CR-39 nuclear track detectors. Single ion hit patterns were achieved with a positioning accuracy of 2 μm or less. In measurement of single event transient current using this system, the reduction of the pulse height by accumulation of radiation damages was observed by single ion injection to the same local areas. This technique showed a possibility to get some quantitative information about the lateral displacement of an individual radiation effect in silicon PIN photodiodes. This paper will give details of the irradiation system and present results from several experiments.

  6. Reduction in specimen labeling errors after implementation of a positive patient identification system in phlebotomy.

    PubMed

    Morrison, Aileen P; Tanasijevic, Milenko J; Goonan, Ellen M; Lobo, Margaret M; Bates, Michael M; Lipsitz, Stuart R; Bates, David W; Melanson, Stacy E F

    2010-06-01

    Ensuring accurate patient identification is central to preventing medical errors, but it can be challenging. We implemented a bar code-based positive patient identification system for use in inpatient phlebotomy. A before-after design was used to evaluate the impact of the identification system on the frequency of mislabeled and unlabeled samples reported in our laboratory. Labeling errors fell from 5.45 in 10,000 before implementation to 3.2 in 10,000 afterward (P = .0013). An estimated 108 mislabeling events were prevented by the identification system in 1 year. Furthermore, a workflow step requiring manual preprinting of labels, which was accompanied by potential labeling errors in about one quarter of blood "draws," was removed as a result of the new system. After implementation, a higher percentage of patients reported having their wristband checked before phlebotomy. Bar code technology significantly reduced the rate of specimen identification errors.

  7. Prevalence and Characterization of Shiga Toxin-Producing Escherichia coli in Swine Feces Recovered in the National Animal Health Monitoring System's Swine 2000 Study

    PubMed Central

    Fratamico, Pina M.; Bagi, Lori K.; Bush, Eric J.; Solow, Barbara T.

    2004-01-01

    A study was conducted to determine the prevalence of Shiga toxin-producing Escherichia coli (STEC) in swine feces in the United States as part of the National Animal Health Monitoring System's Swine 2000 study. Fecal samples collected from swine operations from 13 of the top 17 swine-producing states were tested for the presence of STEC. After enrichment of swine fecal samples in tryptic soy broth, the samples were tested for the presence of stx1 and stx2 by use of the TaqMan E. coli STX1 and STX2 PCR assays. Enrichments of samples positive for stx1 and/or stx2 were plated, and colony hybridization was performed using digoxigenin-labeled probes complementary to the stx1 and stx2 genes. Positive colonies were picked and confirmed by PCR for the presence of the stx1, stx2, or stx2e genes, and the isolates were serotyped. Out of 687 fecal samples tested using the TaqMan assays, 70% (484 of 687) were positive for Shiga toxin genes, and 54% (370 of 687), 64% (436 of 687), and 38% (261 of 687) were positive for stx1, stx2, and both toxin genes, respectively. Out of 219 isolates that were characterized, 29 (13%) produced stx1, 14 (6%) produced stx2, and 176 (80%) produced stx2e. Twenty-three fecal samples contained at least two STEC strains that had different serotypes but that had the same toxin genes or included a strain that possessed stx1 in addition to a strain that possessed stx2 or stx2e. The STEC isolates belonged to various serogroups, including O2, O5, O7, O8, O9, OX10, O11, O15, OX18, O20, O57, O65, O68, O69, O78, O91, O96, O100, O101, O120, O121, O152, O159, O160, O163, and O untypeable. It is noteworthy that no isolates of serogroup O157 were recovered. Results of this study indicate that swine in the United States harbor STEC that can potentially cause human illness. PMID:15574914

  8. Further evidence for cosmological evolution of the fine structure constant.

    PubMed

    Webb, J K; Murphy, M T; Flambaum, V V; Dzuba, V A; Barrow, J D; Churchill, C W; Prochaska, J X; Wolfe, A M

    2001-08-27

    We describe the results of a search for time variability of the fine structure constant alpha using absorption systems in the spectra of distant quasars. Three large optical data sets and two 21 cm and mm absorption systems provide four independent samples, spanning approximately 23% to 87% of the age of the universe. Each sample yields a smaller alpha in the past and the optical sample shows a 4 sigma deviation: Delta alpha/alpha = -0.72+/-0.18 x 10(-5) over the redshift range 0.5

  9. Orbital Motion of Young Binaries in Ophiuchus and Upper Centaurus–Lupus

    NASA Astrophysics Data System (ADS)

    Schaefer, G. H.; Prato, L.; Simon, M.

    2018-03-01

    We present measurements of the orbital positions and flux ratios of 17 binary and triple systems in the Ophiuchus star-forming region and the Upper Centaurus–Lupus cluster based on adaptive optics imaging at the Keck Observatory. We report the detection of visual companions in MML 50 and MML 53 for the first time, as well as the possible detection of a third component in WSB 21. For six systems in our sample, our measurements provide a second orbital position following their initial discoveries over a decade ago. For eight systems with sufficient orbital coverage, we analyze the range of orbital solutions that fit the data. Ultimately, these observations will help provide the groundwork toward measuring precise masses for these pre-main-sequence stars and understanding the distribution of orbital parameters in young multiple systems.

  10. FaSTR DNA: a new expert system for forensic DNA analysis.

    PubMed

    Power, Timothy; McCabe, Brendan; Harbison, Sally Ann

    2008-06-01

    The automation of DNA profile analysis of reference and crime samples continues to gain pace driven in part by a realisation by the criminal justice system of the positive impact DNA technology can have in aiding in the solution of crime and the apprehension of suspects. Expert systems to automate the profile analysis component of the process are beginning to be developed. In this paper, we report the validation of a new expert system FaSTR DNA, an expert system suitable for the analysis of DNA profiles from single source reference samples and from crime samples. We compare the performance of FaSTR DNA with that of other equivalent systems, GeneMapper ID v3.2 (Applied Biosystems, Foster City, CA) and FSS-i(3) v4 (The Forensic Science Service((R)) DNA expert System Suite FSS-i(3), Forensic Science Service, Birmingham, UK) with GeneScan Analysis v3.7/Genotyper v3.7 software (Applied Biosystems, Foster City, CA, USA) with manual review. We have shown that FaSTR DNA provides an alternative solution to automating DNA profile analysis and is appropriate for implementation into forensic laboratories. The FaSTR DNA system was demonstrated to be comparable in performance to that of GeneMapper ID v3.2 and superior to that of FSS-i(3) v4 for the analysis of DNA profiles from crime samples.

  11. Development of a translation stage for in situ noninvasive analysis and high-resolution imaging

    NASA Astrophysics Data System (ADS)

    Strivay, David; Clar, Mathieu; Rakkaa, Said; Hocquet, Francois-Philippe; Defeyt, Catherine

    2016-11-01

    Noninvasive imaging techniques and analytical instrumentation for cultural heritage object studies have undergone a tremendous development over the last years. Many new miniature and/or handheld systems have been developed and optimized. Nonetheless, these instruments are usually used with a tripod or a manual position system. This is very time consuming when performing point analysis or 2D scanning of a surface. The Centre Européen d'Archéométrie has built a translation system made of pluggable rails of 1 m long with a maximum length and height of 3 m. Three motors embedded in the system allow the platform to be moved along these axis, toward and backward from the sample. The rails hold a displacement system, providing a continuous movement. Any position can be reached with a reproducibility of 0.1 mm. The displacements are controlled by an Ethernet connection through a laptop computer running a multiplatform custom-made software written in JAVA. This software allows a complete control over the positioning using a simple, unique, and concise interface. Automatic scanning can be performed over a large surface of 3 m on 3 m. The Ethernet wires provide also the power for the different motors and, if necessary, the detection head. The platform has been originally designed for a XRF detection head (with its full power alimentation) but now can accommodate many different systems like IR reflectography, digital camera, hyperspectral camera, and Raman probes. The positioning system can be modified to combine the acquisition software of the imaging or analytical techniques and the positioning software.

  12. Evaluation of timing of re-appearance of VBNC Legionella for risk assessment in hospital water distribution systems.

    PubMed

    Marinelli, L; Cottarelli, A; Solimini, A G; Del Cimmuto, A; De Giusti, M

    2017-01-01

    In this study we estimated the presence of Legionella species, viable but non-culturable (VBNC), in hospital water networks. We also evaluated the time and load of Legionella appearance in samples found negative using the standard culture method. A total of 42 samples was obtained from the tap water of five hospital buildings. The samples were tested for Legionella by the standard culture method and were monitored for up to 12 months for the appearance of VBNC Legionella. All the 42 samples were negative at the time of collection. Seven of the 42 samples (17.0%) became positive for Legionella at different times of monitoring. The time to the appearance of VBNC Legionella was extremely variable, from 15 days to 9 months from sampling. The most frequent Legionella species observed were Legionella spp and L. anisa and only in one sample L. pneumophila srg.1. Our study confirms the presence of VBNC Legionella in samples resulting negative using the standard culture method and highlights the different time to its appearance that can occur several months after sampling. The results are important for risk assessment and risk management of engineered water systems.

  13. Legionnaires' disease bacteria in power plant cooling systems: downtime report. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyndall, R.L.; Solomon, J.A.; Christensen, S.W.

    1985-11-01

    Legionnaires' disease bacteria (Legionella) are a normal part of the aquatic community that, when aerosolized, can be pathogenic to man. The downtime study was designed to determine the degree to which Legionella populations are aerosolized during cleaning and maintenance operations in a closed-cycle steam-electric power plant. Both high-volume and impinger air samples were collected prior to and during downtime operations. Emphasis was placed on sampling inside or adjacent to water boxes, condensers, and cooling towers. Control air samples were taken upwind from the plant site. Water and sludge samples were also collected at various locations. In the laboratory, the concentrationsmore » of Legionella were determined using the direct fluorescent antibody method. All positive air samples, and other selected air samples, were injected into guinea pigs to detect infectious Legionella. Legionella could be detected in only 12 of the 127 air samples collected. These were predominantly L. pneumophila, serogroups 1-6. In contrast to the air samples, most of the water and sludge samples were positive for Legionella, again predominantly L. pneumophila, serogroups 1-6. The highest Legionella concentrations were found in sludge samples associated with condenser tube cleaning. Among the water samples, the highest Legionella concentrations were found in cooling towers, immediately after the tower basins were cleaned and refilled, and in condenser tubes. Two of the three cooling tower water samples collected prior to downtime operations were infectious for guinea pigs. 16 refs., 4 figs., 11 tabs.« less

  14. 40 CFR 141.805 - Notification to passengers and crew.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., repeat or follow-up total coliform-positive or E. coli-positive sample result in accordance with § 141... samples in response to a sample result that is E. coli-positive in accordance with § 141.803(g); (4... response to a sample result that is total coliform-positive and E. coli-negative in accordance with § 141...

  15. 40 CFR 141.805 - Notification to passengers and crew.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., repeat or follow-up total coliform-positive or E. coli-positive sample result in accordance with § 141... samples in response to a sample result that is E. coli-positive in accordance with § 141.803(g); (4... response to a sample result that is total coliform-positive and E. coli-negative in accordance with § 141...

  16. Epidemiological evidence of lesser role of thermostable direct hemolysin (TDH)-related hemolysin (TRH) than TDH on Vibrio parahaemolyticus pathogenicity.

    PubMed

    Saito, Shioko; Iwade, Yoshito; Tokuoka, Eisuke; Nishio, Tomohiro; Otomo, Yoshimitsu; Araki, Emiko; Konuma, Hirotaka; Nakagawa, Hiroshi; Tanaka, Hiroyuki; Sugiyama, Kanji; Hasegawa, Akio; Sugita-Konishi, Yoshiko; Hara-Kudo, Yukiko

    2015-02-01

    Vibrio parahaemolyticus carrying the tdh gene, encoding the thermostable direct hemolysin (TDH), or the trh gene, encoding the TDH-related hemolysin (TRH), are both considered virulent strains. There are, however, disproportionally fewer reports of infections caused by seafood contaminated with trh-positive strains than by seafood contaminated with tdh-positive strains. Bivalves such as clams and oysters are the major seafood varieties associated with the infections. In this study, the prevalence of strains possessing the tdh and trh genes was investigated in Japan in 74 samples collected in 2007-2008 and in 177 samples collected in 2010 of domestic bivalves, bloody clams, hen clams, short-neck clams, and rock oysters. The tdh-positive and trh-negative, tdh-negative and trh-positive, and tdh-positive and trh-positive samples represented 5.4%, 12.2%, and 4.1% of all samples collected in 2007-2008, and 5.1%, 18.6%, and 5.6% of all samples collected in 2010, respectively. As determined by polymerase chain reaction, the prevalence of tdh negative and trh positive in all samples was two to four times higher than that of tdh positive and trh negative. In the samples collected in 2010, the tdh-negative and trh-positive V. parahaemolyticus (20 samples) was more often isolated than tdh-positive and trh-negative V. parahaemolyticus (7 samples). The most common serotype of tdh-positive isolates (22 of 24 strains) was pandemic O3:K6. The trh-positive isolates (61 strains) were various serotypes including OUT:KUT. In 330 V. parahaemolyticus outbreaks and sporadic infections in Japan, most outbreaks and sporadic infections were caused by tdh-positive and trh-negative strains (89.4%). The frequencies of infections caused by tdh-negative and trh-positive, and both tdh- and trh-positive strains were 1.2% and 3.0%, respectively. This finding suggests that the virulence of trh might be less than that of tdh, although trh-positive V. parahaemolyticus frequently contaminated bivalves.

  17. [Confirmation of West Nile virus seroreactivity in central nervous system infections of unknown etiology from Ankara Province, Central Anatolia, Turkey].

    PubMed

    Ergünay, Koray; Özkul, Aykut

    2011-04-01

    West Nile virus (WNV) infections may trigger febrile conditions and/or neuroinvasive disease in a portion of the exposed individuals. Serosurveillance data from various regions of Turkey indicate WNV activity. The aim of this study was to confirm the antibody specificity of the serum samples via virus neutralization assay, previously reported to be reactive for WNV IgM. The samples originated from two individuals with the preliminary diagnosis of aseptic meningitis/encephalitis of unknown etiology in 2009 and had been classified as probable WNV infections. Cerebrospinal fluid and sera samples of these patients had been evaluated as negative for WNV RNA and IgG antibodies. Only one serum sample could be included in the neutralization assay due to the limited amounts in the current investigation. The sample was observed as positive in dilutions of 1/20 and 1/40, thus confirming the diagnosis of WNV-related central nervous system infection in a 62 year-old female patient from Ankara, Central Anatolia, Turkey.

  18. Comparison of the recovery of Mycobacterium bovis isolates using the BACTEC MGIT 960 system, BACTEC 460 system, and Middlebrook 7H10 and 7H11 solid media.

    PubMed

    Hines, Nichole; Payeur, Janet B; Hoffman, Lorraine J

    2006-05-01

    The BACTEC Microbacteria Growth Indicator Tube (MGIT) 960 system was evaluated to determine how it compares with the BACTEC 460 radiometric system and solid media for recovery of Mycobacterium bovis from tissue samples. A total of 506 bovine lymph node samples were collected from abattoirs in the United States and Mexico between November 2003 and September 2004. Processed samples were inoculated into an MGIT 960 tube, BACTEC 460 vial, and Middlebrook 7H10 and Middlebrook 7H11 solid media. Ziehl-Neelsen slides were prepared to check for contaminants and confirm the presence of acid-fast positive bacilli. Samples containing acid-fast bacilli were confirmed as members of the Mycobacterium tuberculosis complex by a nucleic acid assay. Niacin and nitrate biochemical tests were used to distinguish M. bovis from M. tuberculosis isolates. Statistical analyses were performed to compare recovery rate, mean time to detection, contamination rates, as well as pair-wise comparisons in each category. The results showed that the MGIT 960 system had a higher recovery rate of M. bovis (122/129) than did the BACTEC 460 (102/129) and solid media system (96/129). The average time to detection was 15.8 days for the MGIT 960 system, 28.2 days for the BACTEC 460 system, and 43.4 days for solid media. Contamination rates were 6.9% for the MGIT 960 system, 3.4% for the BACTEC 460 system, and 21.7% for solid media. These results indicate the MGIT 960 system can be used as an alternative to the BACTEC 460 system for recovering M. bovis from tissue samples.

  19. The Serological and Virological Investigation of Canine Adenovirus Infection on the Dogs

    PubMed Central

    Bulut, Oya; Yapici, Orhan; Avci, Oguzhan; Simsek, Atilla; Atli, Kamil; Dik, Irmak; Yavru, Sibel; Hasircioglu, Sibel; Kale, Mehmet; Mamak, Nuri

    2013-01-01

    Two types of Canine Adenovirus (CAVs), Canine Adenovirus type 1 (CAV-1), the virus which causes infectious canine hepatitis, and Canine Adenovirus type 2 (CAV-2), which causes canine infectious laryngotracheitis, have been found in dogs. In this study, blood samples taken from 111 dogs, which were admitted to the Internal Medicine Clinic of Selcuk University, Faculty of Veterinary Medicine, with clinical symptoms. Seventy-seven dogs were sampled from Isparta and Burdur dog shelters by random sampling, regardless of the clinical findings. Dogs showed a systemic disease, characterized by fever, diarrhea, vomiting, oculonasal discharge, conjunctivitis, severe moist cough, signs of pulmonary disease and dehydration. Two dogs had corneal opacity and photophobia. In serological studies, 188 serum samples were investigated on the presence of CAV antibodies by ELISA. Total 103 (103/188–54.7%) blood samples were detected to be positive for CAV antibodies by ELISA. However, 85 (85/188–45.2%) blood samples were negative. Blood leukocyte samples from dogs were processed and inoculated onto confluent monolayers of MDCK cells using standard virological techniques. After third passage, cells were examined by direct immunoflourescence test for virus isolation. But positive result was not detected. In conclusion, this study clearly demonstrates the high prevalence of CAV infection in dogs. PMID:24223508

  20. Usability of Immunohistochemistry in Forensic Samples With Varying Decomposition.

    PubMed

    Lesnikova, Iana; Schreckenbach, Marc Niclas; Kristensen, Maria Pihlmann; Papanikolaou, Liv Lindegaard; Hamilton-Dutoit, Stephen

    2018-05-24

    Immunohistochemistry (IHC) is an important diagnostic tool in anatomic and surgical pathology but is used less frequently in forensic pathology. Degradation of tissue because of postmortem decomposition is believed to be a major limiting factor, although it is unclear what impact such degradation actually has on IHC staining validity. This study included 120 forensic autopsy samples of liver, lung, and brain tissues obtained for diagnostic purposes. The time from death to autopsy ranged between 1 and more than 14 days. Samples were prepared using the tissue microarray technique. The antibodies chosen for the study included KL1 (for staining bile duct epithelium), S100 (for staining glial cells and myelin), vimentin (for endothelial cells in cerebral blood vessels), and CD45 (for pulmonary lymphocytes). Slides were evaluated by light microscopy. Immunohistochemistry reactions were scored according to a system based on the extent and intensity of the positive stain. An overall correlation between the postmortem interval and the IHC score for all tissue samples was found. Samples from decedents with a postmortem interval of 1 to 3 days showed positive staining with all antibodies, whereas samples from decedents with a longer postmortem interval showed decreased staining rates. Our results suggest that IHC analysis can be successfully used for postmortem diagnosis in a range of autopsy samples showing lesser degrees of decomposition.

  1. Physical properties of star clusters in the outer LMC as observed by the DES

    DOE PAGES

    Pieres, A.; Santiago, B.; Balbinot, E.; ...

    2016-05-26

    The Large Magellanic Cloud (LMC) harbors a rich and diverse system of star clusters, whose ages, chemical abundances, and positions provide information about the LMC history of star formation. We use Science Verification imaging data from the Dark Energy Survey to increase the census of known star clusters in the outer LMC and to derive physical parameters for a large sample of such objects using a spatially and photometrically homogeneous data set. Our sample contains 255 visually identified cluster candidates, of which 109 were not listed in any previous catalog. We quantify the crowding effect for the stellar sample producedmore » by the DES Data Management pipeline and conclude that the stellar completeness is < 10% inside typical LMC cluster cores. We therefore develop a pipeline to sample and measure stellar magnitudes and positions around the cluster candidates using DAOPHOT. We also implement a maximum-likelihood method to fit individual density profiles and colour-magnitude diagrams. For 117 (from a total of 255) of the cluster candidates (28 uncatalogued clusters), we obtain reliable ages, metallicities, distance moduli and structural parameters, confirming their nature as physical systems. The distribution of cluster metallicities shows a radial dependence, with no clusters more metal-rich than [Fe/H] ~ -0.7 beyond 8 kpc from the LMC center. Furthermore, the age distribution has two peaks at ≃ 1.2 Gyr and ≃ 2.7 Gyr.« less

  2. Physical properties of star clusters in the outer LMC as observed by the DES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pieres, A.; Santiago, B.; Balbinot, E.

    The Large Magellanic Cloud (LMC) harbors a rich and diverse system of star clusters, whose ages, chemical abundances, and positions provide information about the LMC history of star formation. We use Science Verification imaging data from the Dark Energy Survey to increase the census of known star clusters in the outer LMC and to derive physical parameters for a large sample of such objects using a spatially and photometrically homogeneous data set. Our sample contains 255 visually identified cluster candidates, of which 109 were not listed in any previous catalog. We quantify the crowding effect for the stellar sample producedmore » by the DES Data Management pipeline and conclude that the stellar completeness is < 10% inside typical LMC cluster cores. We therefore develop a pipeline to sample and measure stellar magnitudes and positions around the cluster candidates using DAOPHOT. We also implement a maximum-likelihood method to fit individual density profiles and colour-magnitude diagrams. For 117 (from a total of 255) of the cluster candidates (28 uncatalogued clusters), we obtain reliable ages, metallicities, distance moduli and structural parameters, confirming their nature as physical systems. The distribution of cluster metallicities shows a radial dependence, with no clusters more metal-rich than [Fe/H] ~ -0.7 beyond 8 kpc from the LMC center. Furthermore, the age distribution has two peaks at ≃ 1.2 Gyr and ≃ 2.7 Gyr.« less

  3. Development of an Efficient Entire-Capsid-Coding-Region Amplification Method for Direct Detection of Poliovirus from Stool Extracts

    PubMed Central

    Kilpatrick, David R.; Nakamura, Tomofumi; Burns, Cara C.; Bukbuk, David; Oderinde, Soji B.; Oberste, M. Steven; Kew, Olen M.; Pallansch, Mark A.; Shimizu, Hiroyuki

    2014-01-01

    Laboratory diagnosis has played a critical role in the Global Polio Eradication Initiative since 1988, by isolating and identifying poliovirus (PV) from stool specimens by using cell culture as a highly sensitive system to detect PV. In the present study, we aimed to develop a molecular method to detect PV directly from stool extracts, with a high efficiency comparable to that of cell culture. We developed a method to efficiently amplify the entire capsid coding region of human enteroviruses (EVs) including PV. cDNAs of the entire capsid coding region (3.9 kb) were obtained from as few as 50 copies of PV genomes. PV was detected from the cDNAs with an improved PV-specific real-time reverse transcription-PCR system and nucleotide sequence analysis of the VP1 coding region. For assay validation, we analyzed 84 stool extracts that were positive for PV in cell culture and detected PV genomes from 100% of the extracts (84/84 samples) with this method in combination with a PV-specific extraction method. PV could be detected in 2/4 stool extract samples that were negative for PV in cell culture. In PV-positive samples, EV species C viruses were also detected with high frequency (27% [23/86 samples]). This method would be useful for direct detection of PV from stool extracts without using cell culture. PMID:25339406

  4. Survey of fungal counts and natural occurrence of aflatoxins in Malaysian starch-based foods.

    PubMed

    Abdullah, N; Nawawi, A; Othman, I

    1998-01-01

    In a survey of starch-based foods sampled from retail outlets in Malaysia, fungal colonies were mostly detected in wheat flour (100%), followed by rice flour (74%), glutinous rice grains (72%), ordinary rice grains (60%), glutinous rice flour (48%) and corn flour (26%). All positive samples of ordinary rice and glutinous rice grains had total fungal counts below 10(3) cfu/g sample, while among the positive rice flour, glutinous rice flour and corn flour samples, the highest total fungal count was more than 10(3) but less than 10(4) cfu/g sample respectively. However, in wheat flour samples total fungal count ranged from 10(2) cfu/g sample to slightly more than 10(4) cfu/g sample. Aflatoxigenic colonies were mostly detected in wheat flour (20%), followed by ordinary rice grains (4%), glutinous rice grains (4%) and glutinous rice flour (2%). No aflatoxigenic colonies were isolated from rice flour and corn flour samples. Screening of aflatoxin B1, aflatoxin B2, aflatoxin G1 and aflatoxin G2 using reversed-phase HPLC were carried out on 84 samples of ordinary rice grains and 83 samples of wheat flour. Two point four percent (2.4%) of ordinary rice grains were positive for aflatoxin G1 and 3.6% were positive for aflatoxin G2. All the positive samples were collected from private homes at concentrations ranging from 3.69-77.50 micrograms/kg. One point two percent (1.2%) of wheat flour samples were positive for aflatoxin B1 at a concentration of 25.62 micrograms/kg, 4.8% were positive for aflatoxin B2 at concentrations ranging from 11.25-252.50 micrograms/kg, 3.6% were positive for aflatoxin G1 at concentrations ranging from 25.00-289.38 micrograms/kg and 13.25% were positive for aflatoxin G2 at concentrations ranging from 16.25-436.25 micrograms/kg. Similarly, positive wheat flour samples were mostly collected from private homes.

  5. Anthropogenic rare earth elements and their spatial distributions in the Han River, South Korea.

    PubMed

    Song, Hyeongseok; Shin, Woo-Jin; Ryu, Jong-Sik; Shin, Hyung Seon; Chung, Heesun; Lee, Kwang-Sik

    2017-04-01

    Rare earth elements (REE) consist of lanthanides (from La to Lu), together with yttrium and scandium, in which anthropogenic REE, such as gadolinium (Gd), lanthanum (La), and samarium (Sm), has emerged as micro-contaminants in natural waters in highly developed countries. Here, we collected water samples in the Han River (HR) and its tributaries flowing through Seoul Capital Area, the world's second largest metropolitan area in order to examine how and to what extent anthropogenic REE anomalies may occur. Water samples show higher light REE concentrations than heavy REE concentrations, while wastewater treatment plant (WWTP) samples display much higher heavy REE concentrations due to high Gd concentration. The PAAS-normalized REE patterns indicate that WWTP samples display the pronounced positive Gd anomalies, in which anthropogenic Gd from magnetic resonance imaging (MRI) diagnostic system occurs as a form of Gd complexation with either Cl - or SO 4 2- . Due to the WWTP, both the HR and tributaries show also positive Gd anomalies and the anthropogenic Gd concentrations increase as a function of the distance from the Paldang dam. This result indicates a positive correlation between populaton, number of MRI instruments, and positive Gd anomaly. Similarly, positive La and Sm anomalies exist in the HR, indicating that the HR is also affected by their point sources. Based on the discharge rate and anthropogenic REE concentrations, their fluxes are estimated to be 952 ± 319 kg/yr, suggesting that this amount of fluxes could disturb REE distribution in the Yellow Sea, and pose harmful effects on aquatic ecosystems. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. USE OF GLOBAL POSITIONING SYSTEM TECHNOLOGY TO TRACK SUBJECTS' LOCATION DURING ENVIRONMENTAL EXPOSURE SAMPLING. (R826786)

    EPA Science Inventory

    The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...

  7. STABLE NITROGEN ISOTOPES AS INDICATORS OF ANTHOPOGENIC ACTIVITIES IN SMALL FRESHWATER SYSTEMS

    EPA Science Inventory

    Stable nitrogen isotope ratios ( 15N) were measured in fish, mussel, and sediment samples taken from 17 small freshwater sites to examine food chain length and trophic position across sites affected by differing levels of anthropogenic activity. Both shoreline development and fis...

  8. Design and first tests of an acoustic positioning and detection system for KM3NeT

    NASA Astrophysics Data System (ADS)

    Simeone, F.; Ameli, F.; Ardid, M.; Bertin, V.; Bonori, M.; Bou-Cabo, M.; Calì, C.; D'Amico, A.; Giovanetti, G.; Imbesi, M.; Keller, P.; Larosa, G.; Llorens, C. D.; Masullo, R.; Randazzo, N.; Riccobene, G.; Speziale, F.; Viola, S.; KM3NeT Consortium

    2012-01-01

    In a deep-sea neutrino telescope it is mandatory to locate the position of the optical sensors with a precision of about 10 cm. To achieve this requirement, an innovative Acoustic Positioning System (APS) has been designed in the frame work of the KM3NeT neutrino telescope. The system will also be able to provide an acoustic guide during the deployment of the telescope’s components and seafloor infrastructures (junction boxes, cables, etc.). A prototype of the system based on the successful acoustic systems of ANTARES and NEMO is being developed. It will consist of an array of hydrophones and a network of acoustic transceivers forming the Long Baseline. All sensors are connected to the telescope data acquisition system and are in phase and synchronised with the telescope master clock. Data from the acoustic sensors, continuously sampled at 192 kHz, will be sent to shore where signal recognition and analysis will be carried out. The design and first tests of the system elements will be presented. This new APS is expected to have better precision compared to the systems used in ANTARES and NEMO, and can also be used as a real-time monitor of acoustic sources and environmental noise in deep sea.

  9. Fully automatic characterization and data collection from crystals of biological macromolecules.

    PubMed

    Svensson, Olof; Malbet-Monaco, Stéphanie; Popov, Alexander; Nurizzo, Didier; Bowler, Matthew W

    2015-08-01

    Considerable effort is dedicated to evaluating macromolecular crystals at synchrotron sources, even for well established and robust systems. Much of this work is repetitive, and the time spent could be better invested in the interpretation of the results. In order to decrease the need for manual intervention in the most repetitive steps of structural biology projects, initial screening and data collection, a fully automatic system has been developed to mount, locate, centre to the optimal diffraction volume, characterize and, if possible, collect data from multiple cryocooled crystals. Using the capabilities of pixel-array detectors, the system is as fast as a human operator, taking an average of 6 min per sample depending on the sample size and the level of characterization required. Using a fast X-ray-based routine, samples are located and centred systematically at the position of highest diffraction signal and important parameters for sample characterization, such as flux, beam size and crystal volume, are automatically taken into account, ensuring the calculation of optimal data-collection strategies. The system is now in operation at the new ESRF beamline MASSIF-1 and has been used by both industrial and academic users for many different sample types, including crystals of less than 20 µm in the smallest dimension. To date, over 8000 samples have been evaluated on MASSIF-1 without any human intervention.

  10. A fully redundant double difference algorithm for obtaining minimum variance estimates from GPS observations

    NASA Technical Reports Server (NTRS)

    Melbourne, William G.

    1986-01-01

    In double differencing a regression system obtained from concurrent Global Positioning System (GPS) observation sequences, one either undersamples the system to avoid introducing colored measurement statistics, or one fully samples the system incurring the resulting non-diagonal covariance matrix for the differenced measurement errors. A suboptimal estimation result will be obtained in the undersampling case and will also be obtained in the fully sampled case unless the color noise statistics are taken into account. The latter approach requires a least squares weighting matrix derived from inversion of a non-diagonal covariance matrix for the differenced measurement errors instead of inversion of the customary diagonal one associated with white noise processes. Presented is the so-called fully redundant double differencing algorithm for generating a weighted double differenced regression system that yields equivalent estimation results, but features for certain cases a diagonal weighting matrix even though the differenced measurement error statistics are highly colored.

  11. Dual-stage trapped-flux magnet cryostat for measurements at high magnetic fields

    DOEpatents

    Islam, Zahirul; Das, Ritesh K.; Weinstein, Roy

    2015-04-14

    A method and a dual-stage trapped-flux magnet cryostat apparatus are provided for implementing enhanced measurements at high magnetic fields. The dual-stage trapped-flux magnet cryostat system includes a trapped-flux magnet (TFM). A sample, for example, a single crystal, is adjustably positioned proximate to the surface of the TFM, using a translation stage such that the distance between the sample and the surface is selectively adjusted. A cryostat is provided with a first separate thermal stage provided for cooling the TFM and with a second separate thermal stage provided for cooling sample.

  12. Improvement in the detection rate of diarrhoeagenic bacteria in human stool specimens by a rapid real-time PCR assay.

    PubMed

    Iijima, Yoshio; Asako, Nahoko T; Aihara, Masanori; Hayashi, Kozaburo

    2004-07-01

    A rapid laboratory system has been developed and evaluated that can simultaneously identify major diarrhoeagenic bacteria, including Salmonella enterica, Vibrio parahaemolyticus, Campylobacter jejuni and Shiga toxin-producing Escherichia coli, in stool specimens by real-time PCR. Specific identification was achieved by using selective TaqMan probes, detecting two targets in each pathogen. A positive result was scored only when both targets of a pathogen were amplified and the difference between threshold cycles for detection was less than five. Diagnosis of enteric bacterial infections using this highly sensitive method, including DNA extraction and real-time PCR, requires only 3 h. Forty stool specimens related to suspected food poisoning outbreaks were analysed: 16 (40%) of these samples were found to be positive for diarrhoeagenic bacteria using a conventional culture method; 28 (70%) were positive using the real-time PCR assay. Of the 12 PCR-positive but culture-negative cases, 11 patients had consumed pathogen-contaminated or high-risk food. Analysis of faecal samples from 105 outpatients who complained of diarrhoea and/or abdominal pain identified 19 (18%) patients as being positive for diarrhoeagenic bacteria using the culture method. An additional six (6%) patients were found to be positive by PCR analysis.

  13. Simplified Pan-species Real-time PCR-based Detection of Plasmodium Spp. in Blood Smear.

    PubMed

    Hassanpour, Gholamreza; Mirhendi, Hossein; Mohebali, Mehdi; Raeisi, Ahmad; Zeraati, Hojjat; Keshavarz, Hossein

    2016-01-01

    We aimed to quicken and simplify the detection of Plasmodium in blood samples by developing and testing a pan- Plasmodium real-time PCR for accurate screening of individuals suspected of malaria. A single primer/probe set for pan-species Plasmodium -specific real time PCR targeting a conserved region of the small subunit 18S ribosomal DNA was designed and evaluated for rapid diagnosis and screening of malaria infections using dried blood smears. FTA cards were used for rapid and simple DNA extraction. The primers and probes showed a positive response with the DNA extracted from bloods infected with P. falciparum and P. vivax but not with DNA extracted from various smears from uninfected blood samples. Seven positive cases positive by both microscopy and nested PCR were found among 280 blood samples taken from in South and Southeast Iran. Five samples were identified as positive for P. vivax and two as positive for P. falciparum . All positive samples were positive by real-time PCR. Furthermore, all 38-blood samples positive by microscopy were positive by real-time PCR. No microscopy-negative samples were positive by real-time PCR. By using a simple FTA card for DNA extraction and by application of the real-time PCR developed in this study, sensitivity similar to nested-PCR and microscopy was achieved. This format simplifies the detection of Plasmodium in large numbers of samples.

  14. Risk factors for avian influenza virus in backyard poultry flocks and environments in Zhejiang Province, China: a cross-sectional study.

    PubMed

    Wang, Xiao-Xiao; Cheng, Wei; Yu, Zhao; Liu, She-Lan; Mao, Hai-Yan; Chen, En-Fu

    2018-06-19

    Human infection of avian influenza virus (AIV) remains a great concern. Although live poultry markets are believed to be associated with human infections, ever more infections have been reported in rural areas with backyard poultry, especially in the fifth epidemic of H7N9. However, limited information is available on backyard poultry infection and surrounding environmental contamination. Two surveillance systems and a field survey were used to collect data and samples in Zhejiang Province. In total, 4538 samples were collected by surveillance systems and 3171 from the field survey between May 2015 and May 2017, while 352 backyard poultry owners were interviewed in May 2017 by questionnaire to investigate factors influencing the prevalence of avian influenza A virus and other AIV subtypes. RT-PCR was used to test the nucleic acids of viruses. ArcGIS 10.1 software was used to generate maps. Univariate and logistic regression analyses were conducted to identify risk factors for AIV infection. Of the 428 poultry premises observed by the surveillance system, 53 (12.38%) were positive for influenza A virus. Of the 352 samples from poultry premises observed by field survey, 13 (3.39%) were positive for influenza A virus. The prevalence of AIV was unevenly distributed and the dominant subtype differed among cities. Eastern (Shaoxing and Ningbo) and southern (Wenzhou) cities exhibited a higher prevalence of AIV (16.33, 8.94, and 7.30% respectively). Contamination of AIV subtypes was most severe in January, especially in 2016 (23.26%, 70/301). The positive rate of subtype H5/H7/H9 was 2.53% (115/4538). Subtype H5 was the least prevalent, while subtypes H7 and H9 had similar positivity rates (1.50 and 1.32% respectively). Poultry flocks and environmental samples had a similar prevalence of AIV (4.46% vs 5.06%). The type of live birds was a risk factor and the sanitary condition of the setting was a protective factor against influenza A contamination. AIV subtypes were prevalent in backyard poultry flocks and surrounding environments in Zhejiang Province. The types of live birds and sanitary conditions of the environment were associated with influenza A contamination. These findings shine a light on the characteristics of contamination of AIV subtypes and emphasize the importance of reducing AIV circulation in backyard poultry settings.

  15. Assessment of beryllium and molybdenum nuclear data files with the RPI neutron scattering system in the energy region from 0.5 to 20 MeV

    NASA Astrophysics Data System (ADS)

    Daskalakis, Adam; Blain, Ezekiel; Leinweber, Gregory; Rapp, Michael; Barry, Devin; Block, Robert; Danon, Yaron

    2017-09-01

    A series of neutron scattering benchmark measurements were performed on beryllium and molybdenum with the Rensselaer Polytechnic Institute's Neutron Scattering System. The pulsed neutron source was produced by the Rensselaer Polytechnic Institute's Linear Accelerator and a well collimated neutron beam was incident onto the samples located at a distance of 30.07 m. Neutrons that scattered from the sample were measured using the time-of-flight by eight EJ-301 liquid scintillator detectors positioned 0.5 m from the sample of interest. A total of eight experiments were performed with two sample thicknesses each, measured by detectors placed at two sets of angles. All data were processed using pulse shape analysis that separated the neutron and gamma ray events and included a gamma misclassification correction to account for erroneously identified gamma rays. A detailed model of the neutron scattering system simulated each experiment with several current evaluated nuclear data libraries and their predecessors. Results for each evaluation were compared to the experimental data using a figure-of-merit. The neutron scattering system has been used as a means to quantify a library's performance.

  16. EnEx-RANGE - Robust autonomous Acoustic Navigation in Glacial icE

    NASA Astrophysics Data System (ADS)

    Heinen, Dirk; Eliseev, Dmitry; Henke, Christoph; Jeschke, Sabina; Linder, Peter; Reuter, Sebastian; Schönitz, Sebastian; Scholz, Franziska; Weinstock, Lars Steffen; Wickmann, Stefan; Wiebusch, Christopher; Zierke, Simon

    2017-03-01

    Within the Enceladus Explorer Initiative of the DLR Space Administration navigation technologies for a future space mission are in development. Those technologies are the basis for the search for extraterrestrial life on the Saturn moon Enceladus. An autonomous melting probe, the EnEx probe, aims to extract a liquid sample from a water reservoir below the icy crust. A first EnEx probe was developed and demonstrated in a terrestrial scenario at the Bloodfalls, Taylor Glacier, Antarctica in November 2014. To enable navigation in glacier ice two acoustic systems were integrated into the probe in addition to conventional navigation technologies. The first acoustic system determines the position of the probe during the run based on propagation times of acoustic signals from emitters at reference positions at the glacier surface to receivers in the probe. The second system provides information about the forefield of the probe. It is based on sonographic principles with phased array technology integrated in the probe's melting head. Information about obstacles or sampling regions in the probe's forefield can be acquired. The development of both systems is now continued in the project EnEx-RANGE. The emitters of the localization system are replaced by a network of intelligent acoustic enabled melting probes. These localize each other by means of acoustic signals and create the reference system for the EnEx probe. This presentation includes the discussion of the intelligent acoustic network, the acoustic navigation systems of the EnEx probe and results of terrestrial tests.

  17. Observational study of differences in head position for high notes in famous classical and non-classical male singers.

    PubMed

    Amarante Andrade, Pedro; Švec, Jan G

    2016-07-01

    Differences in classical and non-classical singing are due primarily to aesthetic style requirements. The head position can affect the sound quality. This study aimed at comparing the head position for famous classical and non-classical male singers performing high notes. Images of 39 Western classical and 34 non-classical male singers during live performances were obtained from YouTube. Ten raters evaluated the frontal rotational head position (depression versus elevation) and transverse head position (retraction versus protraction) visually using a visual analogue scale. The results showed a significant difference for frontal rotational head position. Most non-classical singers in the sample elevated their heads for high notes while the classical singers were observed to keep it around the neutral position. This difference may be attributed to different singing techniques and phonatory system adjustments utilized by each group.

  18. MarsVac: Pneumatic Sampling System for Planetary Exploration

    NASA Astrophysics Data System (ADS)

    Zacny, K.; Mungas, G.; Chu, P.; Craft, J.; Davis, K.

    2008-12-01

    We are proposing a Mars Sample Return scheme whereby a sample of regolith is acquired directly into a Mars Ascent Vehicle using a pneumatic system. Unlike prior developments that used suction to collect fines, the proposed system uses positive pressure to move the regolith. We envisage 3 pneumatic tubes to be embedded inside the 3 legs of the lander. Upon landing, the legs will burry themselves into the regolith and the tubes will fill up with regolith. With one puff of gas, the regolith can be lifted into a sampling chamber onboard of the Mars Ascent Vehicle. An additional chamber can be opened to acquire atmospheric gas and dust. The entire MSR will require 1) an actuator to open/close sampling chamber and 2) a valve to open gas cylinder. In the most recent study related to lunar excavation and funded under the NASA SBIR program we have shown that it is possible lift over 3000 grams of soil with only 1 gram of gas at 1atm. Tests conducted under Mars atmospheric pressure conditions (5 torr). In September of 2008, we will be performing tests at 1/6thg (Moon) and 1/3g (Mars) to determine mass lifting efficiencies in reduced gravities.

  19. The NOSAMS sample preparation laboratory in the next millenium: Progress after the WOCE program

    NASA Astrophysics Data System (ADS)

    Gagnon, Alan R.; McNichol, Ann P.; Donoghue, Joanne C.; Stuart, Dana R.; von Reden, Karl; Nosams

    2000-10-01

    Since 1991, the primary charge of the National Ocean Sciences AMS (NOSAMS) facility at the Woods Hole Oceanographic Institution has been to supply high throughput, high precision AMS 14C analyses for seawater samples collected as part of the World Ocean Circulation Experiment (WOCE). Approximately 13,000 samples taken as part of WOCE should be fully analyzed by the end of Y2K. Additional sample sources and techniques must be identified and incorporated if NOSAMS is to continue in its present operation mode. A trend in AMS today is the ability to routinely process and analyze radiocarbon samples that contain tiny amounts (<100 μg) of carbon. The capability to mass-produce small samples for 14C analysis has been recognized as a major facility goal. The installation of a new 134-position MC-SNICS ion source, which utilizes a smaller graphite target cartridge than presently used, is one step towards realizing this goal. New preparation systems constructed in the sample preparation laboratory (SPL) include an automated bank of 10 small-volume graphite reactors, an automated system to process organic carbon samples, and a multi-dimensional preparative capillary gas chromatograph (PCGC).

  20. Grid systems for Earth radiation budget experiment applications

    NASA Technical Reports Server (NTRS)

    Brooks, D. R.

    1981-01-01

    Spatial coordinate transformations are developed for several global grid systems of interest to the Earth Radiation Budget Experiment. The grid boxes are defined in terms of a regional identifier and longitude-latitude indexes. The transformations associate longitude with a particular grid box. The reverse transformations identify the center location of a given grid box. Transformations are given to relate the rotating (Earth-based) grid systems to solar position expressed in an inertial (nonrotating) coordinate system. The FORTRAN implementations of the transformations are given, along with sample input and output.

Top