Public Opinion Polls, Chicken Soup and Sample Size
ERIC Educational Resources Information Center
Nguyen, Phung
2005-01-01
Cooking and tasting chicken soup in three different pots of very different size serves to demonstrate that it is the absolute sample size that matters the most in determining the accuracy of the findings of the poll, not the relative sample size, i.e. the size of the sample in relation to its population.
Biostatistics Series Module 5: Determining Sample Size
Hazra, Avijit; Gogtay, Nithya
2016-01-01
Determining the appropriate sample size for a study, whatever be its type, is a fundamental aspect of biomedical research. An adequate sample ensures that the study will yield reliable information, regardless of whether the data ultimately suggests a clinically important difference between the interventions or elements being studied. The probability of Type 1 and Type 2 errors, the expected variance in the sample and the effect size are the essential determinants of sample size in interventional studies. Any method for deriving a conclusion from experimental data carries with it some risk of drawing a false conclusion. Two types of false conclusion may occur, called Type 1 and Type 2 errors, whose probabilities are denoted by the symbols σ and β. A Type 1 error occurs when one concludes that a difference exists between the groups being compared when, in reality, it does not. This is akin to a false positive result. A Type 2 error occurs when one concludes that difference does not exist when, in reality, a difference does exist, and it is equal to or larger than the effect size defined by the alternative to the null hypothesis. This may be viewed as a false negative result. When considering the risk of Type 2 error, it is more intuitive to think in terms of power of the study or (1 − β). Power denotes the probability of detecting a difference when a difference does exist between the groups being compared. Smaller α or larger power will increase sample size. Conventional acceptable values for power and α are 80% or above and 5% or below, respectively, when calculating sample size. Increasing variance in the sample tends to increase the sample size required to achieve a given power level. The effect size is the smallest clinically important difference that is sought to be detected and, rather than statistical convention, is a matter of past experience and clinical judgment. Larger samples are required if smaller differences are to be detected. Although the principles are long known, historically, sample size determination has been difficult, because of relatively complex mathematical considerations and numerous different formulas. However, of late, there has been remarkable improvement in the availability, capability, and user-friendliness of power and sample size determination software. Many can execute routines for determination of sample size and power for a wide variety of research designs and statistical tests. With the drudgery of mathematical calculation gone, researchers must now concentrate on determining appropriate sample size and achieving these targets, so that study conclusions can be accepted as meaningful. PMID:27688437
Froud, Robert; Rajendran, Dévan; Patel, Shilpa; Bright, Philip; Bjørkli, Tom; Eldridge, Sandra; Buchbinder, Rachelle; Underwood, Martin
2017-06-01
A systematic review of nonspecific low back pain trials published between 1980 and 2012. To explore what proportion of trials have been powered to detect different bands of effect size; whether there is evidence that sample size in low back pain trials has been increasing; what proportion of trial reports include a sample size calculation; and whether likelihood of reporting sample size calculations has increased. Clinical trials should have a sample size sufficient to detect a minimally important difference for a given power and type I error rate. An underpowered trial is one within which probability of type II error is too high. Meta-analyses do not mitigate underpowered trials. Reviewers independently abstracted data on sample size at point of analysis, whether a sample size calculation was reported, and year of publication. Descriptive analyses were used to explore ability to detect effect sizes, and regression analyses to explore the relationship between sample size, or reporting sample size calculations, and time. We included 383 trials. One-third were powered to detect a standardized mean difference of less than 0.5, and 5% were powered to detect less than 0.3. The average sample size was 153 people, which increased only slightly (∼4 people/yr) from 1980 to 2000, and declined slightly (∼4.5 people/yr) from 2005 to 2011 (P < 0.00005). Sample size calculations were reported in 41% of trials. The odds of reporting a sample size calculation (compared to not reporting one) increased until 2005 and then declined (Equation is included in full-text article.). Sample sizes in back pain trials and the reporting of sample size calculations may need to be increased. It may be justifiable to power a trial to detect only large effects in the case of novel interventions. 3.
Sampling for area estimation: A comparison of full-frame sampling with the sample segment approach
NASA Technical Reports Server (NTRS)
Hixson, M.; Bauer, M. E.; Davis, B. J. (Principal Investigator)
1979-01-01
The author has identified the following significant results. Full-frame classifications of wheat and non-wheat for eighty counties in Kansas were repetitively sampled to simulate alternative sampling plans. Evaluation of four sampling schemes involving different numbers of samples and different size sampling units shows that the precision of the wheat estimates increased as the segment size decreased and the number of segments was increased. Although the average bias associated with the various sampling schemes was not significantly different, the maximum absolute bias was directly related to sampling size unit.
NASA Astrophysics Data System (ADS)
Jalava, P. I.; Wang, Q.; Kuuspalo, K.; Ruusunen, J.; Hao, L.; Fang, D.; Väisänen, O.; Ruuskanen, A.; Sippula, O.; Happo, M. S.; Uski, O.; Kasurinen, S.; Torvela, T.; Koponen, H.; Lehtinen, K. E. J.; Komppula, M.; Gu, C.; Jokiniemi, J.; Hirvonen, M.-R.
2015-11-01
Urban air particulate pollution is a known cause for adverse human health effects worldwide. China has encountered air quality problems in recent years due to rapid industrialization. Toxicological effects induced by particulate air pollution vary with particle sizes and season. However, it is not known how distinctively different photochemical activity and different emission sources during the day and the night affect the chemical composition of the PM size ranges and subsequently how it is reflected to the toxicological properties of the PM exposures. The particulate matter (PM) samples were collected in four different size ranges (PM10-2.5; PM2.5-1; PM1-0.2 and PM0.2) with a high volume cascade impactor. The PM samples were extracted with methanol, dried and thereafter used in the chemical and toxicological analyses. RAW264.7 macrophages were exposed to the particulate samples in four different doses for 24 h. Cytotoxicity, inflammatory parameters, cell cycle and genotoxicity were measured after exposure of the cells to particulate samples. Particles were characterized for their chemical composition, including ions, element and PAH compounds, and transmission electron microscopy (TEM) was used to take images of the PM samples. Chemical composition and the induced toxicological responses of the size segregated PM samples showed considerable size dependent differences as well as day to night variation. The PM10-2.5 and the PM0.2 samples had the highest inflammatory potency among the size ranges. Instead, almost all the PM samples were equally cytotoxic and only minor differences were seen in genotoxicity and cell cycle effects. Overall, the PM0.2 samples had the highest toxic potential among the different size ranges in many parameters. PAH compounds in the samples and were generally more abundant during the night than the day, indicating possible photo-oxidation of the PAH compounds due to solar radiation. This was reflected to different toxicity in the PM samples. Some of the day to night difference may have been caused also by differing wind directions transporting air masses from different emission sources during the day and the night. The present findings indicate the important role of the local particle sources and atmospheric processes on the health related toxicological properties of the PM. The varying toxicological responses evoked by the PM samples showed the importance of examining various particle sizes. Especially the detected considerable toxicological activity by PM0.2 size range suggests they're attributable to combustion sources, new particle formation and atmospheric processes.
Probability of coincidental similarity among the orbits of small bodies - I. Pairing
NASA Astrophysics Data System (ADS)
Jopek, Tadeusz Jan; Bronikowska, Małgorzata
2017-09-01
Probability of coincidental clustering among orbits of comets, asteroids and meteoroids depends on many factors like: the size of the orbital sample searched for clusters or the size of the identified group, it is different for groups of 2,3,4,… members. Probability of coincidental clustering is assessed by the numerical simulation, therefore, it depends also on the method used for the synthetic orbits generation. We have tested the impact of some of these factors. For a given size of the orbital sample we have assessed probability of random pairing among several orbital populations of different sizes. We have found how these probabilities vary with the size of the orbital samples. Finally, keeping fixed size of the orbital sample we have shown that the probability of random pairing can be significantly different for the orbital samples obtained by different observation techniques. Also for the user convenience we have obtained several formulae which, for given size of the orbital sample can be used to calculate the similarity threshold corresponding to the small value of the probability of coincidental similarity among two orbits.
NASA Astrophysics Data System (ADS)
Grulke, Eric A.; Wu, Xiaochun; Ji, Yinglu; Buhr, Egbert; Yamamoto, Kazuhiro; Song, Nam Woong; Stefaniak, Aleksandr B.; Schwegler-Berry, Diane; Burchett, Woodrow W.; Lambert, Joshua; Stromberg, Arnold J.
2018-04-01
Size and shape distributions of gold nanorod samples are critical to their physico-chemical properties, especially their longitudinal surface plasmon resonance. This interlaboratory comparison study developed methods for measuring and evaluating size and shape distributions for gold nanorod samples using transmission electron microscopy (TEM) images. The objective was to determine whether two different samples, which had different performance attributes in their application, were different with respect to their size and/or shape descriptor distributions. Touching particles in the captured images were identified using a ruggedness shape descriptor. Nanorods could be distinguished from nanocubes using an elongational shape descriptor. A non-parametric statistical test showed that cumulative distributions of an elongational shape descriptor, that is, the aspect ratio, were statistically different between the two samples for all laboratories. While the scale parameters of size and shape distributions were similar for both samples, the width parameters of size and shape distributions were statistically different. This protocol fulfills an important need for a standardized approach to measure gold nanorod size and shape distributions for applications in which quantitative measurements and comparisons are important. Furthermore, the validated protocol workflow can be automated, thus providing consistent and rapid measurements of nanorod size and shape distributions for researchers, regulatory agencies, and industry.
Influence of sampling window size and orientation on parafoveal cone packing density
Lombardo, Marco; Serrao, Sebastiano; Ducoli, Pietro; Lombardo, Giuseppe
2013-01-01
We assessed the agreement between sampling windows of different size and orientation on packing density estimates in images of the parafoveal cone mosaic acquired using a flood-illumination adaptive optics retinal camera. Horizontal and vertical oriented sampling windows of different size (320x160 µm, 160x80 µm and 80x40 µm) were selected in two retinal locations along the horizontal meridian in one eye of ten subjects. At each location, cone density tended to decline with decreasing sampling area. Although the differences in cone density estimates were not statistically significant, Bland-Altman plots showed that the agreement between cone density estimated within the different sampling window conditions was moderate. The percentage of the preferred packing arrangements of cones by Voronoi tiles was slightly affected by window size and orientation. The results illustrated the high importance of specifying the size and orientation of the sampling window used to derive cone metric estimates to facilitate comparison of different studies. PMID:24009995
Koltun, G.F.; Helsel, Dennis R.
1986-01-01
Identical stream-bottom material samples, when fractioned to the same size by different techniques, may contain significantly different trace-metal concentrations. Precision of techniques also may differ, which could affect the ability to discriminate between size-fractioned bottom-material samples having different metal concentrations. Bottom-material samples fractioned to less than 0.020 millimeters by means of three common techniques (air elutriation, sieving, and settling) were analyzed for six trace metals to determine whether the technique used to obtain the desired particle-size fraction affects the ability to discriminate between bottom materials having different trace-metal concentrations. In addition, this study attempts to assess whether median trace-metal concentrations in size-fractioned bottom materials of identical origin differ depending on the size-fractioning technique used. Finally, this study evaluates the efficiency of the three size-fractioning techniques in terms of time, expense, and effort involved. Bottom-material samples were collected at two sites in northeastern Ohio: One is located in an undeveloped forested basin, and the other is located in a basin having a mixture of industrial and surface-mining land uses. The sites were selected for their close physical proximity, similar contributing drainage areas, and the likelihood that trace-metal concentrations in the bottom materials would be significantly different. Statistically significant differences in the concentrations of trace metals were detected between bottom-material samples collected at the two sites when the samples had been size-fractioned by means of air elutriation or sieving. Statistical analyses of samples that had been size fractioned by settling in native water were not measurably different in any of the six trace metals analyzed. Results of multiple comparison tests suggest that differences related to size-fractioning technique were evident in median copper, lead, and iron concentrations. Technique-related differences in copper concentrations most likely resulted from contamination of air-elutriated samples by a feed tip on the elutriator apparatus. No technique-related differences were observed in chromium, manganese, or zinc concentrations. Although air elutriation was the most expensive sizefractioning technique investigated, samples fractioned by this technique appeared to provide a superior level of discrimination between metal concentrations present in the bottom materials of the two sites. Sieving was an adequate lower-cost but more laborintensive alternative.
NASA Technical Reports Server (NTRS)
Hixson, M. M.; Bauer, M. E.; Davis, B. J.
1979-01-01
The effect of sampling on the accuracy (precision and bias) of crop area estimates made from classifications of LANDSAT MSS data was investigated. Full-frame classifications of wheat and non-wheat for eighty counties in Kansas were repetitively sampled to simulate alternative sampling plants. Four sampling schemes involving different numbers of samples and different size sampling units were evaluated. The precision of the wheat area estimates increased as the segment size decreased and the number of segments was increased. Although the average bias associated with the various sampling schemes was not significantly different, the maximum absolute bias was directly related to sampling unit size.
Novikov, I; Fund, N; Freedman, L S
2010-01-15
Different methods for the calculation of sample size for simple logistic regression (LR) with one normally distributed continuous covariate give different results. Sometimes the difference can be large. Furthermore, some methods require the user to specify the prevalence of cases when the covariate equals its population mean, rather than the more natural population prevalence. We focus on two commonly used methods and show through simulations that the power for a given sample size may differ substantially from the nominal value for one method, especially when the covariate effect is large, while the other method performs poorly if the user provides the population prevalence instead of the required parameter. We propose a modification of the method of Hsieh et al. that requires specification of the population prevalence and that employs Schouten's sample size formula for a t-test with unequal variances and group sizes. This approach appears to increase the accuracy of the sample size estimates for LR with one continuous covariate.
Estimation of sample size and testing power (part 5).
Hu, Liang-ping; Bao, Xiao-lei; Guan, Xue; Zhou, Shi-guo
2012-02-01
Estimation of sample size and testing power is an important component of research design. This article introduced methods for sample size and testing power estimation of difference test for quantitative and qualitative data with the single-group design, the paired design or the crossover design. To be specific, this article introduced formulas for sample size and testing power estimation of difference test for quantitative and qualitative data with the above three designs, the realization based on the formulas and the POWER procedure of SAS software and elaborated it with examples, which will benefit researchers for implementing the repetition principle.
Frank R. Thompson; Monica J. Schwalbach
1995-01-01
We report results of a point count survey of breeding birds on Hoosier National Forest in Indiana. We determined sample size requirements to detect differences in means and the effects of count duration and plot size on individual detection rates. Sample size requirements ranged from 100 to >1000 points with Type I and II error rates of <0.1 and 0.2. Sample...
Mevik, Kjersti; Griffin, Frances A; Hansen, Tonje E; Deilkås, Ellen T; Vonen, Barthold
2016-04-25
To investigate the impact of increasing sample of records reviewed bi-weekly with the Global Trigger Tool method to identify adverse events in hospitalised patients. Retrospective observational study. A Norwegian 524-bed general hospital trust. 1920 medical records selected from 1 January to 31 December 2010. Rate, type and severity of adverse events identified in two different samples sizes of records selected as 10 and 70 records, bi-weekly. In the large sample, 1.45 (95% CI 1.07 to 1.97) times more adverse events per 1000 patient days (39.3 adverse events/1000 patient days) were identified than in the small sample (27.2 adverse events/1000 patient days). Hospital-acquired infections were the most common category of adverse events in both the samples, and the distributions of the other categories of adverse events did not differ significantly between the samples. The distribution of severity level of adverse events did not differ between the samples. The findings suggest that while the distribution of categories and severity are not dependent on the sample size, the rate of adverse events is. Further studies are needed to conclude if the optimal sample size may need to be adjusted based on the hospital size in order to detect a more accurate rate of adverse events. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Reporting of sample size calculations in analgesic clinical trials: ACTTION systematic review.
McKeown, Andrew; Gewandter, Jennifer S; McDermott, Michael P; Pawlowski, Joseph R; Poli, Joseph J; Rothstein, Daniel; Farrar, John T; Gilron, Ian; Katz, Nathaniel P; Lin, Allison H; Rappaport, Bob A; Rowbotham, Michael C; Turk, Dennis C; Dworkin, Robert H; Smith, Shannon M
2015-03-01
Sample size calculations determine the number of participants required to have sufficiently high power to detect a given treatment effect. In this review, we examined the reporting quality of sample size calculations in 172 publications of double-blind randomized controlled trials of noninvasive pharmacologic or interventional (ie, invasive) pain treatments published in European Journal of Pain, Journal of Pain, and Pain from January 2006 through June 2013. Sixty-five percent of publications reported a sample size calculation but only 38% provided all elements required to replicate the calculated sample size. In publications reporting at least 1 element, 54% provided a justification for the treatment effect used to calculate sample size, and 24% of studies with continuous outcome variables justified the variability estimate. Publications of clinical pain condition trials reported a sample size calculation more frequently than experimental pain model trials (77% vs 33%, P < .001) but did not differ in the frequency of reporting all required elements. No significant differences in reporting of any or all elements were detected between publications of trials with industry and nonindustry sponsorship. Twenty-eight percent included a discrepancy between the reported number of planned and randomized participants. This study suggests that sample size calculation reporting in analgesic trial publications is usually incomplete. Investigators should provide detailed accounts of sample size calculations in publications of clinical trials of pain treatments, which is necessary for reporting transparency and communication of pre-trial design decisions. In this systematic review of analgesic clinical trials, sample size calculations and the required elements (eg, treatment effect to be detected; power level) were incompletely reported. A lack of transparency regarding sample size calculations may raise questions about the appropriateness of the calculated sample size. Copyright © 2015 American Pain Society. All rights reserved.
Petruzzellis, Francesco; Palandrani, Chiara; Savi, Tadeja; Alberti, Roberto; Nardini, Andrea; Bacaro, Giovanni
2017-12-01
The choice of the best sampling strategy to capture mean values of functional traits for a species/population, while maintaining information about traits' variability and minimizing the sampling size and effort, is an open issue in functional trait ecology. Intraspecific variability (ITV) of functional traits strongly influences sampling size and effort. However, while adequate information is available about intraspecific variability between individuals (ITV BI ) and among populations (ITV POP ), relatively few studies have analyzed intraspecific variability within individuals (ITV WI ). Here, we provide an analysis of ITV WI of two foliar traits, namely specific leaf area (SLA) and osmotic potential (π), in a population of Quercus ilex L. We assessed the baseline ITV WI level of variation between the two traits and provided the minimum and optimal sampling size in order to take into account ITV WI , comparing sampling optimization outputs with those previously proposed in the literature. Different factors accounted for different amount of variance of the two traits. SLA variance was mostly spread within individuals (43.4% of the total variance), while π variance was mainly spread between individuals (43.2%). Strategies that did not account for all the canopy strata produced mean values not representative of the sampled population. The minimum size to adequately capture the studied functional traits corresponded to 5 leaves taken randomly from 5 individuals, while the most accurate and feasible sampling size was 4 leaves taken randomly from 10 individuals. We demonstrate that the spatial structure of the canopy could significantly affect traits variability. Moreover, different strategies for different traits could be implemented during sampling surveys. We partially confirm sampling sizes previously proposed in the recent literature and encourage future analysis involving different traits.
Bergh, Daniel
2015-01-01
Chi-square statistics are commonly used for tests of fit of measurement models. Chi-square is also sensitive to sample size, which is why several approaches to handle large samples in test of fit analysis have been developed. One strategy to handle the sample size problem may be to adjust the sample size in the analysis of fit. An alternative is to adopt a random sample approach. The purpose of this study was to analyze and to compare these two strategies using simulated data. Given an original sample size of 21,000, for reductions of sample sizes down to the order of 5,000 the adjusted sample size function works as good as the random sample approach. In contrast, when applying adjustments to sample sizes of lower order the adjustment function is less effective at approximating the chi-square value for an actual random sample of the relevant size. Hence, the fit is exaggerated and misfit under-estimated using the adjusted sample size function. Although there are big differences in chi-square values between the two approaches at lower sample sizes, the inferences based on the p-values may be the same.
Jorgenson, Andrew K; Clark, Brett
2013-01-01
This study examines the regional and temporal differences in the statistical relationship between national-level carbon dioxide emissions and national-level population size. The authors analyze panel data from 1960 to 2005 for a diverse sample of nations, and employ descriptive statistics and rigorous panel regression modeling techniques. Initial descriptive analyses indicate that all regions experienced overall increases in carbon emissions and population size during the 45-year period of investigation, but with notable differences. For carbon emissions, the sample of countries in Asia experienced the largest percent increase, followed by countries in Latin America, Africa, and lastly the sample of relatively affluent countries in Europe, North America, and Oceania combined. For population size, the sample of countries in Africa experienced the largest percent increase, followed countries in Latin America, Asia, and the combined sample of countries in Europe, North America, and Oceania. Findings for two-way fixed effects panel regression elasticity models of national-level carbon emissions indicate that the estimated elasticity coefficient for population size is much smaller for nations in Africa than for nations in other regions of the world. Regarding potential temporal changes, from 1960 to 2005 the estimated elasticity coefficient for population size decreased by 25% for the sample of Africa countries, 14% for the sample of Asia countries, 6.5% for the sample of Latin America countries, but remained the same in size for the sample of countries in Europe, North America, and Oceania. Overall, while population size continues to be the primary driver of total national-level anthropogenic carbon dioxide emissions, the findings for this study highlight the need for future research and policies to recognize that the actual impacts of population size on national-level carbon emissions differ across both time and region.
Bony pelvic canal size and shape in relation to body proportionality in humans.
Kurki, Helen K
2013-05-01
Obstetric selection acts on the female pelvic canal to accommodate the human neonate and contributes to pelvic sexual dimorphism. There is a complex relationship between selection for obstetric sufficiency and for overall body size in humans. The relationship between selective pressures may differ among populations of different body sizes and proportions, as pelvic canal dimensions vary among populations. Size and shape of the pelvic canal in relation to body size and shape were examined using nine skeletal samples (total female n = 57; male n = 84) from diverse geographical regions. Pelvic, vertebral, and lower limb bone measurements were collected. Principal component analyses demonstrate pelvic canal size and shape differences among the samples. Male multivariate variance in pelvic shape is greater than female variance for North and South Africans. High-latitude samples have larger and broader bodies, and pelvic canals of larger size and, among females, relatively broader medio-lateral dimensions relative to low-latitude samples, which tend to display relatively expanded inlet antero-posterior (A-P) and posterior canal dimensions. Differences in canal shape exist among samples that are not associated with latitude or body size, suggesting independence of some canal shape characteristics from body size and shape. The South Africans are distinctive with very narrow bodies and small pelvic inlets relative to an elongated lower canal in A-P and posterior lengths. Variation in pelvic canal geometry among populations is consistent with a high degree of evolvability in the human pelvis. Copyright © 2013 Wiley Periodicals, Inc.
Chen, Xiao; Lu, Bin; Yan, Chao-Gan
2018-01-01
Concerns regarding reproducibility of resting-state functional magnetic resonance imaging (R-fMRI) findings have been raised. Little is known about how to operationally define R-fMRI reproducibility and to what extent it is affected by multiple comparison correction strategies and sample size. We comprehensively assessed two aspects of reproducibility, test-retest reliability and replicability, on widely used R-fMRI metrics in both between-subject contrasts of sex differences and within-subject comparisons of eyes-open and eyes-closed (EOEC) conditions. We noted permutation test with Threshold-Free Cluster Enhancement (TFCE), a strict multiple comparison correction strategy, reached the best balance between family-wise error rate (under 5%) and test-retest reliability/replicability (e.g., 0.68 for test-retest reliability and 0.25 for replicability of amplitude of low-frequency fluctuations (ALFF) for between-subject sex differences, 0.49 for replicability of ALFF for within-subject EOEC differences). Although R-fMRI indices attained moderate reliabilities, they replicated poorly in distinct datasets (replicability < 0.3 for between-subject sex differences, < 0.5 for within-subject EOEC differences). By randomly drawing different sample sizes from a single site, we found reliability, sensitivity and positive predictive value (PPV) rose as sample size increased. Small sample sizes (e.g., < 80 [40 per group]) not only minimized power (sensitivity < 2%), but also decreased the likelihood that significant results reflect "true" effects (PPV < 0.26) in sex differences. Our findings have implications for how to select multiple comparison correction strategies and highlight the importance of sufficiently large sample sizes in R-fMRI studies to enhance reproducibility. Hum Brain Mapp 39:300-318, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Shieh, Gwowen
2013-01-01
The a priori determination of a proper sample size necessary to achieve some specified power is an important problem encountered frequently in practical studies. To establish the needed sample size for a two-sample "t" test, researchers may conduct the power analysis by specifying scientifically important values as the underlying population means…
What is the optimum sample size for the study of peatland testate amoeba assemblages?
Mazei, Yuri A; Tsyganov, Andrey N; Esaulov, Anton S; Tychkov, Alexander Yu; Payne, Richard J
2017-10-01
Testate amoebae are widely used in ecological and palaeoecological studies of peatlands, particularly as indicators of surface wetness. To ensure data are robust and comparable it is important to consider methodological factors which may affect results. One significant question which has not been directly addressed in previous studies is how sample size (expressed here as number of Sphagnum stems) affects data quality. In three contrasting locations in a Russian peatland we extracted samples of differing size, analysed testate amoebae and calculated a number of widely-used indices: species richness, Simpson diversity, compositional dissimilarity from the largest sample and transfer function predictions of water table depth. We found that there was a trend for larger samples to contain more species across the range of commonly-used sample sizes in ecological studies. Smaller samples sometimes failed to produce counts of testate amoebae often considered minimally adequate. It seems likely that analyses based on samples of different sizes may not produce consistent data. Decisions about sample size need to reflect trade-offs between logistics, data quality, spatial resolution and the disturbance involved in sample extraction. For most common ecological applications we suggest that samples of more than eight Sphagnum stems are likely to be desirable. Copyright © 2017 Elsevier GmbH. All rights reserved.
Cui, Zaixu; Gong, Gaolang
2018-06-02
Individualized behavioral/cognitive prediction using machine learning (ML) regression approaches is becoming increasingly applied. The specific ML regression algorithm and sample size are two key factors that non-trivially influence prediction accuracies. However, the effects of the ML regression algorithm and sample size on individualized behavioral/cognitive prediction performance have not been comprehensively assessed. To address this issue, the present study included six commonly used ML regression algorithms: ordinary least squares (OLS) regression, least absolute shrinkage and selection operator (LASSO) regression, ridge regression, elastic-net regression, linear support vector regression (LSVR), and relevance vector regression (RVR), to perform specific behavioral/cognitive predictions based on different sample sizes. Specifically, the publicly available resting-state functional MRI (rs-fMRI) dataset from the Human Connectome Project (HCP) was used, and whole-brain resting-state functional connectivity (rsFC) or rsFC strength (rsFCS) were extracted as prediction features. Twenty-five sample sizes (ranged from 20 to 700) were studied by sub-sampling from the entire HCP cohort. The analyses showed that rsFC-based LASSO regression performed remarkably worse than the other algorithms, and rsFCS-based OLS regression performed markedly worse than the other algorithms. Regardless of the algorithm and feature type, both the prediction accuracy and its stability exponentially increased with increasing sample size. The specific patterns of the observed algorithm and sample size effects were well replicated in the prediction using re-testing fMRI data, data processed by different imaging preprocessing schemes, and different behavioral/cognitive scores, thus indicating excellent robustness/generalization of the effects. The current findings provide critical insight into how the selected ML regression algorithm and sample size influence individualized predictions of behavior/cognition and offer important guidance for choosing the ML regression algorithm or sample size in relevant investigations. Copyright © 2018 Elsevier Inc. All rights reserved.
Effects of tree-to-tree variations on sap flux-based transpiration estimates in a forested watershed
NASA Astrophysics Data System (ADS)
Kume, Tomonori; Tsuruta, Kenji; Komatsu, Hikaru; Kumagai, Tomo'omi; Higashi, Naoko; Shinohara, Yoshinori; Otsuki, Kyoichi
2010-05-01
To estimate forest stand-scale water use, we assessed how sample sizes affect confidence of stand-scale transpiration (E) estimates calculated from sap flux (Fd) and sapwood area (AS_tree) measurements of individual trees. In a Japanese cypress plantation, we measured Fd and AS_tree in all trees (n = 58) within a 20 × 20 m study plot, which was divided into four 10 × 10 subplots. We calculated E from stand AS_tree (AS_stand) and mean stand Fd (JS) values. Using Monte Carlo analyses, we examined potential errors associated with sample sizes in E, AS_stand, and JS by using the original AS_tree and Fd data sets. Consequently, we defined optimal sample sizes of 10 and 15 for AS_stand and JS estimates, respectively, in the 20 × 20 m plot. Sample sizes greater than the optimal sample sizes did not decrease potential errors. The optimal sample sizes for JS changed according to plot size (e.g., 10 × 10 m and 10 × 20 m), while the optimal sample sizes for AS_stand did not. As well, the optimal sample sizes for JS did not change in different vapor pressure deficit conditions. In terms of E estimates, these results suggest that the tree-to-tree variations in Fd vary among different plots, and that plot size to capture tree-to-tree variations in Fd is an important factor. This study also discusses planning balanced sampling designs to extrapolate stand-scale estimates to catchment-scale estimates.
Duy, Pham K; Chun, Seulah; Chung, Hoeil
2017-11-21
We have systematically characterized Raman scatterings in solid samples with different particle sizes and investigated subsequent trends of particle size-induced intensity variations. For this purpose, both lactose powders and pellets composed of five different particle sizes were prepared. Uniquely in this study, three spectral acquisition schemes with different sizes of laser illuminations and detection windows were employed for the evaluation, since it was expected that the experimental configuration would be another factor potentially influencing the intensity of the lactose peak, along with the particle size itself. In both samples, the distribution of Raman photons became broader with the increase in particle size, as the mean free path of laser photons, the average photon travel distance between consecutive scattering locations, became longer under this situation. When the particle size was the same, the Raman photon distribution was narrower in the pellets since the individual particles were more densely packed in a given volume (the shorter mean free path). When the size of the detection window was small, the number of photons reaching the detector decreased as the photon distribution was larger. Meanwhile, a large-window detector was able to collect the widely distributed Raman photons more effectively; therefore, the trends of intensity change with the variation in particle size were dissimilar depending on the employed spectral acquisition schemes. Overall, the Monte Carlo simulation was effective at probing the photon distribution inside the samples and helped to support the experimental observations.
Small sample sizes in the study of ontogenetic allometry; implications for palaeobiology
Vavrek, Matthew J.
2015-01-01
Quantitative morphometric analyses, particularly ontogenetic allometry, are common methods used in quantifying shape, and changes therein, in both extinct and extant organisms. Due to incompleteness and the potential for restricted sample sizes in the fossil record, palaeobiological analyses of allometry may encounter higher rates of error. Differences in sample size between fossil and extant studies and any resulting effects on allometric analyses have not been thoroughly investigated, and a logical lower threshold to sample size is not clear. Here we show that studies based on fossil datasets have smaller sample sizes than those based on extant taxa. A similar pattern between vertebrates and invertebrates indicates this is not a problem unique to either group, but common to both. We investigate the relationship between sample size, ontogenetic allometric relationship and statistical power using an empirical dataset of skull measurements of modern Alligator mississippiensis. Across a variety of subsampling techniques, used to simulate different taphonomic and/or sampling effects, smaller sample sizes gave less reliable and more variable results, often with the result that allometric relationships will go undetected due to Type II error (failure to reject the null hypothesis). This may result in a false impression of fewer instances of positive/negative allometric growth in fossils compared to living organisms. These limitations are not restricted to fossil data and are equally applicable to allometric analyses of rare extant taxa. No mathematically derived minimum sample size for ontogenetic allometric studies is found; rather results of isometry (but not necessarily allometry) should not be viewed with confidence at small sample sizes. PMID:25780770
NASA Astrophysics Data System (ADS)
Lusiana, Evellin Dewi
2017-12-01
The parameters of binary probit regression model are commonly estimated by using Maximum Likelihood Estimation (MLE) method. However, MLE method has limitation if the binary data contains separation. Separation is the condition where there are one or several independent variables that exactly grouped the categories in binary response. It will result the estimators of MLE method become non-convergent, so that they cannot be used in modeling. One of the effort to resolve the separation is using Firths approach instead. This research has two aims. First, to identify the chance of separation occurrence in binary probit regression model between MLE method and Firths approach. Second, to compare the performance of binary probit regression model estimator that obtained by MLE method and Firths approach using RMSE criteria. Those are performed using simulation method and under different sample size. The results showed that the chance of separation occurrence in MLE method for small sample size is higher than Firths approach. On the other hand, for larger sample size, the probability decreased and relatively identic between MLE method and Firths approach. Meanwhile, Firths estimators have smaller RMSE than MLEs especially for smaller sample sizes. But for larger sample sizes, the RMSEs are not much different. It means that Firths estimators outperformed MLE estimator.
Sampling stratospheric aerosols with impactors
NASA Technical Reports Server (NTRS)
Oberbeck, Verne R.
1989-01-01
Derivation of statistically significant size distributions from impactor samples of rarefield stratospheric aerosols imposes difficult sampling constraints on collector design. It is shown that it is necessary to design impactors of different size for each range of aerosol size collected so as to obtain acceptable levels of uncertainty with a reasonable amount of data reduction.
[Sample size calculation in clinical post-marketing evaluation of traditional Chinese medicine].
Fu, Yingkun; Xie, Yanming
2011-10-01
In recent years, as the Chinese government and people pay more attention on the post-marketing research of Chinese Medicine, part of traditional Chinese medicine breed has or is about to begin after the listing of post-marketing evaluation study. In the post-marketing evaluation design, sample size calculation plays a decisive role. It not only ensures the accuracy and reliability of post-marketing evaluation. but also assures that the intended trials will have a desired power for correctly detecting a clinically meaningful difference of different medicine under study if such a difference truly exists. Up to now, there is no systemic method of sample size calculation in view of the traditional Chinese medicine. In this paper, according to the basic method of sample size calculation and the characteristic of the traditional Chinese medicine clinical evaluation, the sample size calculation methods of the Chinese medicine efficacy and safety are discussed respectively. We hope the paper would be beneficial to medical researchers, and pharmaceutical scientists who are engaged in the areas of Chinese medicine research.
Simulation analyses of space use: Home range estimates, variability, and sample size
Bekoff, Marc; Mech, L. David
1984-01-01
Simulations of space use by animals were run to determine the relationship among home range area estimates, variability, and sample size (number of locations). As sample size increased, home range size increased asymptotically, whereas variability decreased among mean home range area estimates generated by multiple simulations for the same sample size. Our results suggest that field workers should ascertain between 100 and 200 locations in order to estimate reliably home range area. In some cases, this suggested guideline is higher than values found in the few published studies in which the relationship between home range area and number of locations is addressed. Sampling differences for small species occupying relatively small home ranges indicate that fewer locations may be sufficient to allow for a reliable estimate of home range. Intraspecific variability in social status (group member, loner, resident, transient), age, sex, reproductive condition, and food resources also have to be considered, as do season, habitat, and differences in sampling and analytical methods. Comparative data still are needed.
Observational studies of patients in the emergency department: a comparison of 4 sampling methods.
Valley, Morgan A; Heard, Kennon J; Ginde, Adit A; Lezotte, Dennis C; Lowenstein, Steven R
2012-08-01
We evaluate the ability of 4 sampling methods to generate representative samples of the emergency department (ED) population. We analyzed the electronic records of 21,662 consecutive patient visits at an urban, academic ED. From this population, we simulated different models of study recruitment in the ED by using 2 sample sizes (n=200 and n=400) and 4 sampling methods: true random, random 4-hour time blocks by exact sample size, random 4-hour time blocks by a predetermined number of blocks, and convenience or "business hours." For each method and sample size, we obtained 1,000 samples from the population. Using χ(2) tests, we measured the number of statistically significant differences between the sample and the population for 8 variables (age, sex, race/ethnicity, language, triage acuity, arrival mode, disposition, and payer source). Then, for each variable, method, and sample size, we compared the proportion of the 1,000 samples that differed from the overall ED population to the expected proportion (5%). Only the true random samples represented the population with respect to sex, race/ethnicity, triage acuity, mode of arrival, language, and payer source in at least 95% of the samples. Patient samples obtained using random 4-hour time blocks and business hours sampling systematically differed from the overall ED patient population for several important demographic and clinical variables. However, the magnitude of these differences was not large. Common sampling strategies selected for ED-based studies may affect parameter estimates for several representative population variables. However, the potential for bias for these variables appears small. Copyright © 2012. Published by Mosby, Inc.
NASA Astrophysics Data System (ADS)
Negassa, Wakene; Guber, Andrey; Kravchenko, Alexandra; Rivers, Mark
2014-05-01
Soil's potential to sequester carbon (C) depends not only on quality and quantity of organic inputs to soil but also on the residence time of the applied organic inputs within the soil. Soil pore structure is one of the main factors that influence residence time of soil organic matter by controlling gas exchange, soil moisture and microbial activities, thereby soil C sequestration capacity. Previous attempts to investigate the fate of organic inputs added to soil did not allow examining their decomposition in situ; the drawback that can now be remediated by application of X-ray computed micro-tomography (µ-CT). The non-destructive and non-invasive nature of µ-CT gives an opportunity to investigate the effect of soil pore size distributions on decomposition of plant residues at a new quantitative level. The objective of this study is to examine the influence of pore size distributions on the decomposition of plant residue added to soil. Samples with contrasting pore size distributions were created using aggregate fractions of five different sizes (<0.05, 0.05-0.1, 0.10-05, 0.5-1.0 and 1.0-2.0 mm). Weighted average pore diameters ranged from 10 µm (<0.05 mm fraction) to 104 µm (1-2 mm fraction), while maximum pore diameter were in a range from 29 µm (<0.05 mm fraction) to 568 µm (1-2 mm fraction) in the created soil samples. Dried pieces of maize leaves 2.5 mg in size (equivalent to 1.71 mg C g-1 soil) were added to half of the studied samples. Samples with and without maize leaves were incubated for 120 days. CO2 emission from the samples was measured at regular time intervals. In order to ensure that the observed differences are due to differences in pore structure and not due to differences in inherent properties of the studied aggregate fractions, we repeated the whole experiment using soil from the same aggregate size fractions but ground to <0.05 mm size. Five to six replicated samples were used for intact and ground samples of all sizes with and without leaves. Two replications of the intact aggregate fractions of all sizes with leaves were subjected to µ-CT scanning before and after incubation, whereas all the remaining replications of both intact and ground aggregate fractions of <0.05, 0.05-0.1, and 1.0-2.0 mm sizes with leaves were scanned with µ-CT after the incubation. The µ-CT image showed that approximately 80% of the leaves in the intact samples of large aggregate fractions (0.5-1.0 and 1.0-2.0 mm) was decomposed during the incubation, while only 50-60% of the leaves were decomposed in the intact samples of smaller sized fractions. Even lower percent of leaves (40-50%) was decomposed in the ground samples, with very similar leaf decomposition observed in all ground samples regardless of the aggregate fraction size. Consistent with µ-CT results, the proportion of decomposed leaf estimated with the conventional mass loss method was 48% and 60% for the <0.05 mm and 1.0-2.0 mm soil size fractions of intact aggregates, and 40-50% in ground samples, respectively. The results of the incubation experiment demonstrated that, while greater C mineralization was observed in samples of all size fractions amended with leaf, the effect of leaf presence was most pronounced in the smaller aggregate fractions (0.05-0.1 mm and 0.05 mm) of intact aggregates. The results of the present study unequivocally demonstrate that differences in pore size distributions have a major effect on the decomposition of plant residues added to soil. Moreover, in presence of plant residues, differences in pore size distributions appear to also influence the rates of decomposition of the intrinsic soil organic material.
Treatment Trials for Neonatal Seizures: The Effect of Design on Sample Size
Stevenson, Nathan J.; Boylan, Geraldine B.; Hellström-Westas, Lena; Vanhatalo, Sampsa
2016-01-01
Neonatal seizures are common in the neonatal intensive care unit. Clinicians treat these seizures with several anti-epileptic drugs (AEDs) to reduce seizures in a neonate. Current AEDs exhibit sub-optimal efficacy and several randomized control trials (RCT) of novel AEDs are planned. The aim of this study was to measure the influence of trial design on the required sample size of a RCT. We used seizure time courses from 41 term neonates with hypoxic ischaemic encephalopathy to build seizure treatment trial simulations. We used five outcome measures, three AED protocols, eight treatment delays from seizure onset (Td) and four levels of trial AED efficacy to simulate different RCTs. We performed power calculations for each RCT design and analysed the resultant sample size. We also assessed the rate of false positives, or placebo effect, in typical uncontrolled studies. We found that the false positive rate ranged from 5 to 85% of patients depending on RCT design. For controlled trials, the choice of outcome measure had the largest effect on sample size with median differences of 30.7 fold (IQR: 13.7–40.0) across a range of AED protocols, Td and trial AED efficacy (p<0.001). RCTs that compared the trial AED with positive controls required sample sizes with a median fold increase of 3.2 (IQR: 1.9–11.9; p<0.001). Delays in AED administration from seizure onset also increased the required sample size 2.1 fold (IQR: 1.7–2.9; p<0.001). Subgroup analysis showed that RCTs in neonates treated with hypothermia required a median fold increase in sample size of 2.6 (IQR: 2.4–3.0) compared to trials in normothermic neonates (p<0.001). These results show that RCT design has a profound influence on the required sample size. Trials that use a control group, appropriate outcome measure, and control for differences in Td between groups in analysis will be valid and minimise sample size. PMID:27824913
Jorgenson, Andrew K.; Clark, Brett
2013-01-01
This study examines the regional and temporal differences in the statistical relationship between national-level carbon dioxide emissions and national-level population size. The authors analyze panel data from 1960 to 2005 for a diverse sample of nations, and employ descriptive statistics and rigorous panel regression modeling techniques. Initial descriptive analyses indicate that all regions experienced overall increases in carbon emissions and population size during the 45-year period of investigation, but with notable differences. For carbon emissions, the sample of countries in Asia experienced the largest percent increase, followed by countries in Latin America, Africa, and lastly the sample of relatively affluent countries in Europe, North America, and Oceania combined. For population size, the sample of countries in Africa experienced the largest percent increase, followed countries in Latin America, Asia, and the combined sample of countries in Europe, North America, and Oceania. Findings for two-way fixed effects panel regression elasticity models of national-level carbon emissions indicate that the estimated elasticity coefficient for population size is much smaller for nations in Africa than for nations in other regions of the world. Regarding potential temporal changes, from 1960 to 2005 the estimated elasticity coefficient for population size decreased by 25% for the sample of Africa countries, 14% for the sample of Asia countries, 6.5% for the sample of Latin America countries, but remained the same in size for the sample of countries in Europe, North America, and Oceania. Overall, while population size continues to be the primary driver of total national-level anthropogenic carbon dioxide emissions, the findings for this study highlight the need for future research and policies to recognize that the actual impacts of population size on national-level carbon emissions differ across both time and region. PMID:23437323
Revisiting sample size: are big trials the answer?
Lurati Buse, Giovanna A L; Botto, Fernando; Devereaux, P J
2012-07-18
The superiority of the evidence generated in randomized controlled trials over observational data is not only conditional to randomization. Randomized controlled trials require proper design and implementation to provide a reliable effect estimate. Adequate random sequence generation, allocation implementation, analyses based on the intention-to-treat principle, and sufficient power are crucial to the quality of a randomized controlled trial. Power, or the probability of the trial to detect a difference when a real difference between treatments exists, strongly depends on sample size. The quality of orthopaedic randomized controlled trials is frequently threatened by a limited sample size. This paper reviews basic concepts and pitfalls in sample-size estimation and focuses on the importance of large trials in the generation of valid evidence.
Sample size and power for cost-effectiveness analysis (part 1).
Glick, Henry A
2011-03-01
Basic sample size and power formulae for cost-effectiveness analysis have been established in the literature. These formulae are reviewed and the similarities and differences between sample size and power for cost-effectiveness analysis and for the analysis of other continuous variables such as changes in blood pressure or weight are described. The types of sample size and power tables that are commonly calculated for cost-effectiveness analysis are also described and the impact of varying the assumed parameter values on the resulting sample size and power estimates is discussed. Finally, the way in which the data for these calculations may be derived are discussed.
Estimation of sample size and testing power (Part 4).
Hu, Liang-ping; Bao, Xiao-lei; Guan, Xue; Zhou, Shi-guo
2012-01-01
Sample size estimation is necessary for any experimental or survey research. An appropriate estimation of sample size based on known information and statistical knowledge is of great significance. This article introduces methods of sample size estimation of difference test for data with the design of one factor with two levels, including sample size estimation formulas and realization based on the formulas and the POWER procedure of SAS software for quantitative data and qualitative data with the design of one factor with two levels. In addition, this article presents examples for analysis, which will play a leading role for researchers to implement the repetition principle during the research design phase.
Xu, Huacheng; Guo, Laodong
2017-06-15
Dissolved organic matter (DOM) is ubiquitous in natural waters. The ecological role and environmental fate of DOM are highly related to the chemical composition and size distribution. To evaluate size-dependent DOM quantity and quality, water samples were collected from river, lake, and coastal marine environments and size fractionated through a series of micro- and ultra-filtrations with different membranes having different pore-sizes/cutoffs, including 0.7, 0.4, and 0.2 μm and 100, 10, 3, and 1 kDa. Abundance of dissolved organic carbon, total carbohydrates, chromophoric and fluorescent components in the filtrates decreased consistently with decreasing filter/membrane cutoffs, but with a rapid decline when the filter cutoff reached 3 kDa, showing an evident size-dependent DOM abundance and composition. About 70% of carbohydrates and 90% of humic- and protein-like components were measured in the <3 kDa fraction in freshwater samples, but these percentages were higher in the seawater sample. Spectroscopic properties of DOM, such as specific ultraviolet absorbance, spectral slope, and biological and humification indices also varied significantly with membrane cutoffs. In addition, different ultrafiltration membranes with the same manufacture-rated cutoff also gave rise to different DOM retention efficiencies and thus different colloidal abundances and size spectra. Thus, the size-dependent DOM properties were related to both sample types and membranes used. Our results here provide not only baseline data for filter pore-size selection when exploring DOM ecological and environmental roles, but also new insights into better understanding the physical definition of DOM and its size continuum in quantity and quality in aquatic environments. Copyright © 2017 Elsevier Ltd. All rights reserved.
Optimal flexible sample size design with robust power.
Zhang, Lanju; Cui, Lu; Yang, Bo
2016-08-30
It is well recognized that sample size determination is challenging because of the uncertainty on the treatment effect size. Several remedies are available in the literature. Group sequential designs start with a sample size based on a conservative (smaller) effect size and allow early stop at interim looks. Sample size re-estimation designs start with a sample size based on an optimistic (larger) effect size and allow sample size increase if the observed effect size is smaller than planned. Different opinions favoring one type over the other exist. We propose an optimal approach using an appropriate optimality criterion to select the best design among all the candidate designs. Our results show that (1) for the same type of designs, for example, group sequential designs, there is room for significant improvement through our optimization approach; (2) optimal promising zone designs appear to have no advantages over optimal group sequential designs; and (3) optimal designs with sample size re-estimation deliver the best adaptive performance. We conclude that to deal with the challenge of sample size determination due to effect size uncertainty, an optimal approach can help to select the best design that provides most robust power across the effect size range of interest. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Kunz, Cornelia U; Stallard, Nigel; Parsons, Nicholas; Todd, Susan; Friede, Tim
2017-03-01
Regulatory authorities require that the sample size of a confirmatory trial is calculated prior to the start of the trial. However, the sample size quite often depends on parameters that might not be known in advance of the study. Misspecification of these parameters can lead to under- or overestimation of the sample size. Both situations are unfavourable as the first one decreases the power and the latter one leads to a waste of resources. Hence, designs have been suggested that allow a re-assessment of the sample size in an ongoing trial. These methods usually focus on estimating the variance. However, for some methods the performance depends not only on the variance but also on the correlation between measurements. We develop and compare different methods for blinded estimation of the correlation coefficient that are less likely to introduce operational bias when the blinding is maintained. Their performance with respect to bias and standard error is compared to the unblinded estimator. We simulated two different settings: one assuming that all group means are the same and one assuming that different groups have different means. Simulation results show that the naïve (one-sample) estimator is only slightly biased and has a standard error comparable to that of the unblinded estimator. However, if the group means differ, other estimators have better performance depending on the sample size per group and the number of groups. © 2016 The Authors. Biometrical Journal Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Stallard, Nigel; Parsons, Nicholas; Todd, Susan; Friede, Tim
2016-01-01
Regulatory authorities require that the sample size of a confirmatory trial is calculated prior to the start of the trial. However, the sample size quite often depends on parameters that might not be known in advance of the study. Misspecification of these parameters can lead to under‐ or overestimation of the sample size. Both situations are unfavourable as the first one decreases the power and the latter one leads to a waste of resources. Hence, designs have been suggested that allow a re‐assessment of the sample size in an ongoing trial. These methods usually focus on estimating the variance. However, for some methods the performance depends not only on the variance but also on the correlation between measurements. We develop and compare different methods for blinded estimation of the correlation coefficient that are less likely to introduce operational bias when the blinding is maintained. Their performance with respect to bias and standard error is compared to the unblinded estimator. We simulated two different settings: one assuming that all group means are the same and one assuming that different groups have different means. Simulation results show that the naïve (one‐sample) estimator is only slightly biased and has a standard error comparable to that of the unblinded estimator. However, if the group means differ, other estimators have better performance depending on the sample size per group and the number of groups. PMID:27886393
Estimating population size with correlated sampling unit estimates
David C. Bowden; Gary C. White; Alan B. Franklin; Joseph L. Ganey
2003-01-01
Finite population sampling theory is useful in estimating total population size (abundance) from abundance estimates of each sampled unit (quadrat). We develop estimators that allow correlated quadrat abundance estimates, even for quadrats in different sampling strata. Correlated quadrat abundance estimates based on markârecapture or distance sampling methods occur...
Luminescence isochron dating: a new approach using different grain sizes.
Zhao, H; Li, S H
2002-01-01
A new approach to isochron dating is described using different sizes of quartz and K-feldspar grains. The technique can be applied to sites with time-dependent external dose rates. It is assumed that any underestimation of the equivalent dose (De) using K-feldspar is by a factor F, which is independent of grain size (90-350 microm) for a given sample. Calibration of the beta source for different grain sizes is discussed, and then the sample ages are calculated using the differences between quartz and K-feldspar De from grains of similar size. Two aeolian sediment samples from north-eastern China are used to illustrate the application of the new method. It is confirmed that the observed values of De derived using K-feldspar underestimate the expected doses (based on the quartz De) but, nevertheless, these K-feldspar De values correlate linearly with the calculated internal dose rate contribution, supporting the assumption that the underestimation factor F is independent of grain size. The isochron ages are also compared with the results obtained using quartz De and the measured external dose rates.
Some physical properties of Apollo 12 lunar samples
NASA Technical Reports Server (NTRS)
Gold, T.; Oleary, B. T.; Campbell, M.
1971-01-01
The size distribution of the lunar fines is measured, and small but significant differences are found between the Apollo 11 and 12 samples as well as among the Apollo 12 core samples. The observed differences in grain size distribtuion in the core samples are related to surface transportation processes, and the importance of a sedimentation process versus meteoritic impact gardening of the mare grounds is discussed. The optical and the radio frequency electrical properties are measured and are also found to differ only slightly from Apollo 11 results.
Design of Phase II Non-inferiority Trials.
Jung, Sin-Ho
2017-09-01
With the development of inexpensive treatment regimens and less invasive surgical procedures, we are confronted with non-inferiority study objectives. A non-inferiority phase III trial requires a roughly four times larger sample size than that of a similar standard superiority trial. Because of the large required sample size, we often face feasibility issues to open a non-inferiority trial. Furthermore, due to lack of phase II non-inferiority trial design methods, we do not have an opportunity to investigate the efficacy of the experimental therapy through a phase II trial. As a result, we often fail to open a non-inferiority phase III trial and a large number of non-inferiority clinical questions still remain unanswered. In this paper, we want to develop some designs for non-inferiority randomized phase II trials with feasible sample sizes. At first, we review a design method for non-inferiority phase III trials. Subsequently, we propose three different designs for non-inferiority phase II trials that can be used under different settings. Each method is demonstrated with examples. Each of the proposed design methods is shown to require a reasonable sample size for non-inferiority phase II trials. The three different non-inferiority phase II trial designs are used under different settings, but require similar sample sizes that are typical for phase II trials.
Hammerstrom, Kamille K; Ranasinghe, J Ananda; Weisberg, Stephen B; Oliver, John S; Fairey, W Russell; Slattery, Peter N; Oakden, James M
2012-10-01
Benthic macrofauna are used extensively for environmental assessment, but the area sampled and sieve sizes used to capture animals often differ among studies. Here, we sampled 80 sites using 3 different sized sampling areas (0.1, 0.05, 0.0071 m(2)) and sieved those sediments through each of 2 screen sizes (0.5, 1 mm) to evaluate their effect on number of individuals, number of species, dominance, nonmetric multidimensional scaling (MDS) ordination, and benthic community condition indices that are used to assess sediment quality in California. Sample area had little effect on abundance but substantially affected numbers of species, which are not easily scaled to a standard area. Sieve size had a substantial effect on both measures, with the 1-mm screen capturing only 74% of the species and 68% of the individuals collected in the 0.5-mm screen. These differences, though, had little effect on the ability to differentiate samples along gradients in ordination space. Benthic indices generally ranked sample condition in the same order regardless of gear, although the absolute scoring of condition was affected by gear type. The largest differences in condition assessment were observed for the 0.0071-m(2) gear. Benthic indices based on numbers of species were more affected than those based on relative abundance, primarily because we were unable to scale species number to a common area as we did for abundance. Copyright © 2010 SETAC.
Qualitative Meta-Analysis on the Hospital Task: Implications for Research
ERIC Educational Resources Information Center
Noll, Jennifer; Sharma, Sashi
2014-01-01
The "law of large numbers" indicates that as sample size increases, sample statistics become less variable and more closely estimate their corresponding population parameters. Different research studies investigating how people consider sample size when evaluating the reliability of a sample statistic have found a wide range of…
Herzog, Sereina A; Low, Nicola; Berghold, Andrea
2015-06-19
The success of an intervention to prevent the complications of an infection is influenced by the natural history of the infection. Assumptions about the temporal relationship between infection and the development of sequelae can affect the predicted effect size of an intervention and the sample size calculation. This study investigates how a mathematical model can be used to inform sample size calculations for a randomised controlled trial (RCT) using the example of Chlamydia trachomatis infection and pelvic inflammatory disease (PID). We used a compartmental model to imitate the structure of a published RCT. We considered three different processes for the timing of PID development, in relation to the initial C. trachomatis infection: immediate, constant throughout, or at the end of the infectious period. For each process we assumed that, of all women infected, the same fraction would develop PID in the absence of an intervention. We examined two sets of assumptions used to calculate the sample size in a published RCT that investigated the effect of chlamydia screening on PID incidence. We also investigated the influence of the natural history parameters of chlamydia on the required sample size. The assumed event rates and effect sizes used for the sample size calculation implicitly determined the temporal relationship between chlamydia infection and PID in the model. Even small changes in the assumed PID incidence and relative risk (RR) led to considerable differences in the hypothesised mechanism of PID development. The RR and the sample size needed per group also depend on the natural history parameters of chlamydia. Mathematical modelling helps to understand the temporal relationship between an infection and its sequelae and can show how uncertainties about natural history parameters affect sample size calculations when planning a RCT.
Sample-size needs for forestry herbicide trials
S.M. Zedaker; T.G. Gregoire; James H. Miller
1994-01-01
Forest herbicide experiments are increasingly being designed to evaluate smaller treatment differences when comparing existing effective treatments, tank mix ratios, surfactants, and new low-rate products. The ability to detect small differences in efficacy is dependent upon the relationship among sample size. type I and II error probabilities, and the coefficients of...
Estimating numbers of females with cubs-of-the-year in the Yellowstone grizzly bear population
Keating, K.A.; Schwartz, C.C.; Haroldson, M.A.; Moody, D.
2001-01-01
For grizzly bears (Ursus arctos horribilis) in the Greater Yellowstone Ecosystem (GYE), minimum population size and allowable numbers of human-caused mortalities have been calculated as a function of the number of unique females with cubs-of-the-year (FCUB) seen during a 3- year period. This approach underestimates the total number of FCUB, thereby biasing estimates of population size and sustainable mortality. Also, it does not permit calculation of valid confidence bounds. Many statistical methods can resolve or mitigate these problems, but there is no universal best method. Instead, relative performances of different methods can vary with population size, sample size, and degree of heterogeneity among sighting probabilities for individual animals. We compared 7 nonparametric estimators, using Monte Carlo techniques to assess performances over the range of sampling conditions deemed plausible for the Yellowstone population. Our goal was to estimate the number of FCUB present in the population each year. Our evaluation differed from previous comparisons of such estimators by including sample coverage methods and by treating individual sightings, rather than sample periods, as the sample unit. Consequently, our conclusions also differ from earlier studies. Recommendations regarding estimators and necessary sample sizes are presented, together with estimates of annual numbers of FCUB in the Yellowstone population with bootstrap confidence bounds.
C. Kerry Overton; Michael A. Radko; Rodger L. Nelson
1993-01-01
Differences in fish habitat variables between two studied watersheds may be related to differences in land management. In using the R1/R4 Watershed-Scale Fish Habitat Inventory Process, for most habitat variables, evaluations of sample sizes of at least 30 habitat units were adequate. Guidelines will help land managers in determining sample sizes required to detect...
Myatt, Julia P; Crompton, Robin H; Thorpe, Susannah K S
2011-01-01
By relating an animal's morphology to its functional role and the behaviours performed, we can further develop our understanding of the selective factors and constraints acting on the adaptations of great apes. Comparison of muscle architecture between different ape species, however, is difficult because only small sample sizes are ever available. Further, such samples are often comprised of different age–sex classes, so studies have to rely on scaling techniques to remove body mass differences. However, the reliability of such scaling techniques has been questioned. As datasets increase in size, more reliable statistical analysis may eventually become possible. Here we employ geometric and allometric scaling techniques, and ancovas (a form of general linear model, GLM) to highlight and explore the different methods available for comparing functional morphology in the non-human great apes. Our results underline the importance of regressing data against a suitable body size variable to ascertain the relationship (geometric or allometric) and of choosing appropriate exponents by which to scale data. ancova models, while likely to be more robust than scaling for species comparisons when sample sizes are high, suffer from reduced power when sample sizes are low. Therefore, until sample sizes are radically increased it is preferable to include scaling analyses along with ancovas in data exploration. Overall, the results obtained from the different methods show little significant variation, whether in muscle belly mass, fascicle length or physiological cross-sectional area between the different species. This may reflect relatively close evolutionary relationships of the non-human great apes; a universal influence on morphology of generalised orthograde locomotor behaviours or, quite likely, both. PMID:21507000
ERIC Educational Resources Information Center
Guo, Jiin-Huarng; Luh, Wei-Ming
2008-01-01
This study proposes an approach for determining appropriate sample size for Welch's F test when unequal variances are expected. Given a certain maximum deviation in population means and using the quantile of F and t distributions, there is no need to specify a noncentrality parameter and it is easy to estimate the approximate sample size needed…
ERIC Educational Resources Information Center
Shieh, Gwowen; Jan, Show-Li
2013-01-01
The authors examined 2 approaches for determining the required sample size of Welch's test for detecting equality of means when the greatest difference between any 2 group means is given. It is shown that the actual power obtained with the sample size of the suggested approach is consistently at least as great as the nominal power. However, the…
NASA Astrophysics Data System (ADS)
Atapour, Hadi; Mortazavi, Ali
2018-04-01
The effects of textural characteristics, especially grain size, on index properties of weakly solidified artificial sandstones are studied. For this purpose, a relatively large number of laboratory tests were carried out on artificial sandstones that were produced in the laboratory. The prepared samples represent fifteen sandstone types consisting of five different median grain sizes and three different cement contents. Indices rock properties including effective porosity, bulk density, point load strength index, and Schmidt hammer values (SHVs) were determined. Experimental results showed that the grain size has significant effects on index properties of weakly solidified sandstones. The porosity of samples is inversely related to the grain size and decreases linearly as grain size increases. While a direct relationship was observed between grain size and dry bulk density, as bulk density increased with increasing median grain size. Furthermore, it was observed that the point load strength index and SHV of samples increased as a result of grain size increase. These observations are indirectly related to the porosity decrease as a function of median grain size.
Hajeb, Parvaneh; Herrmann, Susan S; Poulsen, Mette E
2017-07-19
The guidance document SANTE 11945/2015 recommends that cereal samples be milled to a particle size preferably smaller than 1.0 mm and that extensive heating of the samples should be avoided. The aim of the present study was therefore to investigate the differences in milling procedures, obtained particle size distributions, and the resulting pesticide residue recovery when cereal samples were milled at the European Union National Reference Laboratories (NRLs) with their routine milling procedures. A total of 23 NRLs participated in the study. The oat and rye samples milled by each NRL were sent to the European Union Reference Laboratory on Cereals and Feedingstuff (EURL) for the determination of the particle size distribution and pesticide residue recovery. The results showed that the NRLs used several different brands and types of mills. Large variations in the particle size distributions and pesticide extraction efficiencies were observed even between samples milled by the same type of mill.
Simulation on Poisson and negative binomial models of count road accident modeling
NASA Astrophysics Data System (ADS)
Sapuan, M. S.; Razali, A. M.; Zamzuri, Z. H.; Ibrahim, K.
2016-11-01
Accident count data have often been shown to have overdispersion. On the other hand, the data might contain zero count (excess zeros). The simulation study was conducted to create a scenarios which an accident happen in T-junction with the assumption the dependent variables of generated data follows certain distribution namely Poisson and negative binomial distribution with different sample size of n=30 to n=500. The study objective was accomplished by fitting Poisson regression, negative binomial regression and Hurdle negative binomial model to the simulated data. The model validation was compared and the simulation result shows for each different sample size, not all model fit the data nicely even though the data generated from its own distribution especially when the sample size is larger. Furthermore, the larger sample size indicates that more zeros accident count in the dataset.
Peel, D; Waples, R S; Macbeth, G M; Do, C; Ovenden, J R
2013-03-01
Theoretical models are often applied to population genetic data sets without fully considering the effect of missing data. Researchers can deal with missing data by removing individuals that have failed to yield genotypes and/or by removing loci that have failed to yield allelic determinations, but despite their best efforts, most data sets still contain some missing data. As a consequence, realized sample size differs among loci, and this poses a problem for unbiased methods that must explicitly account for random sampling error. One commonly used solution for the calculation of contemporary effective population size (N(e) ) is to calculate the effective sample size as an unweighted mean or harmonic mean across loci. This is not ideal because it fails to account for the fact that loci with different numbers of alleles have different information content. Here we consider this problem for genetic estimators of contemporary effective population size (N(e) ). To evaluate bias and precision of several statistical approaches for dealing with missing data, we simulated populations with known N(e) and various degrees of missing data. Across all scenarios, one method of correcting for missing data (fixed-inverse variance-weighted harmonic mean) consistently performed the best for both single-sample and two-sample (temporal) methods of estimating N(e) and outperformed some methods currently in widespread use. The approach adopted here may be a starting point to adjust other population genetics methods that include per-locus sample size components. © 2012 Blackwell Publishing Ltd.
Simple, Defensible Sample Sizes Based on Cost Efficiency
Bacchetti, Peter; McCulloch, Charles E.; Segal, Mark R.
2009-01-01
Summary The conventional approach of choosing sample size to provide 80% or greater power ignores the cost implications of different sample size choices. Costs, however, are often impossible for investigators and funders to ignore in actual practice. Here, we propose and justify a new approach for choosing sample size based on cost efficiency, the ratio of a study’s projected scientific and/or practical value to its total cost. By showing that a study’s projected value exhibits diminishing marginal returns as a function of increasing sample size for a wide variety of definitions of study value, we are able to develop two simple choices that can be defended as more cost efficient than any larger sample size. The first is to choose the sample size that minimizes the average cost per subject. The second is to choose sample size to minimize total cost divided by the square root of sample size. This latter method is theoretically more justifiable for innovative studies, but also performs reasonably well and has some justification in other cases. For example, if projected study value is assumed to be proportional to power at a specific alternative and total cost is a linear function of sample size, then this approach is guaranteed either to produce more than 90% power or to be more cost efficient than any sample size that does. These methods are easy to implement, based on reliable inputs, and well justified, so they should be regarded as acceptable alternatives to current conventional approaches. PMID:18482055
RnaSeqSampleSize: real data based sample size estimation for RNA sequencing.
Zhao, Shilin; Li, Chung-I; Guo, Yan; Sheng, Quanhu; Shyr, Yu
2018-05-30
One of the most important and often neglected components of a successful RNA sequencing (RNA-Seq) experiment is sample size estimation. A few negative binomial model-based methods have been developed to estimate sample size based on the parameters of a single gene. However, thousands of genes are quantified and tested for differential expression simultaneously in RNA-Seq experiments. Thus, additional issues should be carefully addressed, including the false discovery rate for multiple statistic tests, widely distributed read counts and dispersions for different genes. To solve these issues, we developed a sample size and power estimation method named RnaSeqSampleSize, based on the distributions of gene average read counts and dispersions estimated from real RNA-seq data. Datasets from previous, similar experiments such as the Cancer Genome Atlas (TCGA) can be used as a point of reference. Read counts and their dispersions were estimated from the reference's distribution; using that information, we estimated and summarized the power and sample size. RnaSeqSampleSize is implemented in R language and can be installed from Bioconductor website. A user friendly web graphic interface is provided at http://cqs.mc.vanderbilt.edu/shiny/RnaSeqSampleSize/ . RnaSeqSampleSize provides a convenient and powerful way for power and sample size estimation for an RNAseq experiment. It is also equipped with several unique features, including estimation for interested genes or pathway, power curve visualization, and parameter optimization.
Potential Reporting Bias in Neuroimaging Studies of Sex Differences.
David, Sean P; Naudet, Florian; Laude, Jennifer; Radua, Joaquim; Fusar-Poli, Paolo; Chu, Isabella; Stefanick, Marcia L; Ioannidis, John P A
2018-04-17
Numerous functional magnetic resonance imaging (fMRI) studies have reported sex differences. To empirically evaluate for evidence of excessive significance bias in this literature, we searched for published fMRI studies of human brain to evaluate sex differences, regardless of the topic investigated, in Medline and Scopus over 10 years. We analyzed the prevalence of conclusions in favor of sex differences and the correlation between study sample sizes and number of significant foci identified. In the absence of bias, larger studies (better powered) should identify a larger number of significant foci. Across 179 papers, median sample size was n = 32 (interquartile range 23-47.5). A median of 5 foci related to sex differences were reported (interquartile range, 2-9.5). Few articles (n = 2) had titles focused on no differences or on similarities (n = 3) between sexes. Overall, 158 papers (88%) reached "positive" conclusions in their abstract and presented some foci related to sex differences. There was no statistically significant relationship between sample size and the number of foci (-0.048% increase for every 10 participants, p = 0.63). The extremely high prevalence of "positive" results and the lack of the expected relationship between sample size and the number of discovered foci reflect probable reporting bias and excess significance bias in this literature.
Xu, Jiao; Li, Mei; Shi, Guoliang; Wang, Haiting; Ma, Xian; Wu, Jianhui; Shi, Xurong; Feng, Yinchang
2017-11-15
In this study, single particle mass spectra signatures of both coal burning boiler and biomass burning boiler emitted particles were studied. Particle samples were suspended in clean Resuspension Chamber, and analyzed by ELPI and SPAMS simultaneously. The size distribution of BBB (biomass burning boiler sample) and CBB (coal burning boiler sample) are different, as BBB peaks at smaller size, and CBB peaks at larger size. Mass spectra signatures of two samples were studied by analyzing the average mass spectrum of each particle cluster extracted by ART-2a in different size ranges. In conclusion, BBB sample mostly consists of OC and EC containing particles, and a small fraction of K-rich particles in the size range of 0.2-0.5μm. In 0.5-1.0μm, BBB sample consists of EC, OC, K-rich and Al_Silicate containing particles; CBB sample consists of EC, ECOC containing particles, while Al_Silicate (including Al_Ca_Ti_Silicate, Al_Ti_Silicate, Al_Silicate) containing particles got higher fractions as size increase. The similarity of single particle mass spectrum signatures between two samples were studied by analyzing the dot product, results indicated that part of the single particle mass spectra of two samples in the same size range are similar, which bring challenge to the future source apportionment activity by using single particle aerosol mass spectrometer. Results of this study will provide physicochemical information of important sources which contribute to particle pollution, and will support source apportionment activities. Copyright © 2017. Published by Elsevier B.V.
Hamilton, A J; Waters, E K; Kim, H J; Pak, W S; Furlong, M J
2009-06-01
The combined action of two lepidoteran pests, Plutella xylostella L. (Plutellidae) and Pieris rapae L. (Pieridae),causes significant yield losses in cabbage (Brassica oleracea variety capitata) crops in the Democratic People's Republic of Korea. Integrated pest management (IPM) strategies for these cropping systems are in their infancy, and sampling plans have not yet been developed. We used statistical resampling to assess the performance of fixed sample size plans (ranging from 10 to 50 plants). First, the precision (D = SE/mean) of the plans in estimating the population mean was assessed. There was substantial variation in achieved D for all sample sizes, and sample sizes of at least 20 and 45 plants were required to achieve the acceptable precision level of D < or = 0.3 at least 50 and 75% of the time, respectively. Second, the performance of the plans in classifying the population density relative to an economic threshold (ET) was assessed. To account for the different damage potentials of the two species the ETs were defined in terms of standard insects (SIs), where 1 SI = 1 P. rapae = 5 P. xylostella larvae. The plans were implemented using different economic thresholds (ETs) for the three growth stages of the crop: precupping (1 SI/plant), cupping (0.5 SI/plant), and heading (4 SI/plant). Improvement in the classification certainty with increasing sample sizes could be seen through the increasing steepness of operating characteristic curves. Rather than prescribe a particular plan, we suggest that the results of these analyses be used to inform practitioners of the relative merits of the different sample sizes.
NASA Astrophysics Data System (ADS)
Tian, Shili; Pan, Yuepeng; Wang, Jian; Wang, Yuesi
2016-11-01
Current science and policy requirements have focused attention on the need to expand and improve particulate matter (PM) sampling methods. To explore how sampling filter type affects artifacts in PM composition measurements, size-resolved particulate SO42-, NO3- and NH4+ (SNA) were measured on quartz fiber filters (QFF), glass fiber filters (GFF) and cellulose membranes (CM) concurrently in an urban area of Beijing on both clean and hazy days. The results showed that SNA concentrations in most of the size fractions exhibited the following patterns on different filters: CM > QFF > GFF for NH4+; GFF > QFF > CM for SO42-; and GFF > CM > QFF for NO3-. The different patterns in coarse particles were mainly affected by filter acidity, and that in fine particles were mainly affected by hygroscopicity of the filters (especially in size fraction of 0.65-2.1 μm). Filter acidity and hygroscopicity also shifted the peaks of the annual mean size distributions of SNA on QFF from 0.43-0.65 μm on clean days to 0.65-1.1 μm on hazy days. However, this size shift was not as distinct for samples measured with CM and GFF. In addition, relative humidity (RH) and pollution levels are important factors that can enhance particulate size mode shifts of SNA on clean and hazy days. Consequently, the annual mean size distributions of SNA had maxima at 0.65-1.1 μm for QFF samples and 0.43-0.65 μm for GFF and CM samples. Compared with NH4+ and SO42-, NO3- is more sensitive to RH and pollution levels, accordingly, the annual mean size distribution of NO3- exhibited peak at 0.65-1.1 μm for CM samples instead of 0.43-0.65 μm. These methodological uncertainties should be considered when quantifying the concentrations and size distributions of SNA under different RH and haze conditions.
Dempah, Kassibla Elodie; Lubach, Joseph W; Munson, Eric J
2017-03-06
A variety of particle sizes of a model compound, dicumarol, were prepared and characterized in order to investigate the correlation between particle size and solid-state NMR (SSNMR) proton spin-lattice relaxation ( 1 H T 1 ) times. Conventional laser diffraction and scanning electron microscopy were used as particle size measurement techniques and showed crystalline dicumarol samples with sizes ranging from tens of micrometers to a few micrometers. Dicumarol samples were prepared using both bottom-up and top-down particle size control approaches, via antisolvent microprecipitation and cryogrinding. It was observed that smaller particles of dicumarol generally had shorter 1 H T 1 times than larger ones. Additionally, cryomilled particles had the shortest 1 H T 1 times encountered (8 s). SSNMR 1 H T 1 times of all the samples were measured and showed as-received dicumarol to have a T 1 of 1500 s, whereas the 1 H T 1 times of the precipitated samples ranged from 20 to 80 s, with no apparent change in the physical form of dicumarol. Physical mixtures of different sized particles were also analyzed to determine the effect of sample inhomogeneity on 1 H T 1 values. Mixtures of cryoground and as-received dicumarol were clearly inhomogeneous as they did not fit well to a one-component relaxation model, but could be fit much better to a two-component model with both fast-and slow-relaxing regimes. Results indicate that samples of crystalline dicumarol containing two significantly different particle size populations could be deconvoluted solely based on their differences in 1 H T 1 times. Relative populations of each particle size regime could also be approximated using two-component fitting models. Using NMR theory on spin diffusion as a reference, and taking into account the presence of crystal defects, a model for the correlation between the particle size of dicumarol and its 1 H T 1 time was proposed.
NASA Astrophysics Data System (ADS)
Jamil, Farinaa Md; Sulaiman, Mohd Ali; Ibrahim, Suhaina Mohd; Masrom, Abdul Kadir; Yahya, Muhd Zu Azhan
2017-12-01
A series of mesoporous carbon sample was synthesized using silica template, SBA-15 with two different pore sizes. Impregnation method was applied using glucose as a precursor for converting it into carbon. An appropriate carbonization and silica removal process were carried out to produce a series of mesoporous carbon with different pore sizes and surface areas. Mesoporous carbon sample was then assembled as electrode and its performance was tested using cyclic voltammetry and impedance spectroscopy to study the effect of ion transportation into several pore sizes on electric double layer capacitor (EDLC) system. 6M KOH was used as electrolyte at various scan rates of 10, 20, 30 and 50 mVs-1. The results showed that the pore size of carbon increased as the pore size of template increased and the specific capacitance improved as the increasing of the pore size of carbon.
Trap configuration and spacing influences parameter estimates in spatial capture-recapture models
Sun, Catherine C.; Fuller, Angela K.; Royle, J. Andrew
2014-01-01
An increasing number of studies employ spatial capture-recapture models to estimate population size, but there has been limited research on how different spatial sampling designs and trap configurations influence parameter estimators. Spatial capture-recapture models provide an advantage over non-spatial models by explicitly accounting for heterogeneous detection probabilities among individuals that arise due to the spatial organization of individuals relative to sampling devices. We simulated black bear (Ursus americanus) populations and spatial capture-recapture data to evaluate the influence of trap configuration and trap spacing on estimates of population size and a spatial scale parameter, sigma, that relates to home range size. We varied detection probability and home range size, and considered three trap configurations common to large-mammal mark-recapture studies: regular spacing, clustered, and a temporal sequence of different cluster configurations (i.e., trap relocation). We explored trap spacing and number of traps per cluster by varying the number of traps. The clustered arrangement performed well when detection rates were low, and provides for easier field implementation than the sequential trap arrangement. However, performance differences between trap configurations diminished as home range size increased. Our simulations suggest it is important to consider trap spacing relative to home range sizes, with traps ideally spaced no more than twice the spatial scale parameter. While spatial capture-recapture models can accommodate different sampling designs and still estimate parameters with accuracy and precision, our simulations demonstrate that aspects of sampling design, namely trap configuration and spacing, must consider study area size, ranges of individual movement, and home range sizes in the study population.
NASA Astrophysics Data System (ADS)
Yulia, M.; Suhandy, D.
2018-03-01
NIR spectra obtained from spectral data acquisition system contains both chemical information of samples as well as physical information of the samples, such as particle size and bulk density. Several methods have been established for developing calibration models that can compensate for sample physical information variations. One common approach is to include physical information variation in the calibration model both explicitly and implicitly. The objective of this study was to evaluate the feasibility of using explicit method to compensate the influence of different particle size of coffee powder in NIR calibration model performance. A number of 220 coffee powder samples with two different types of coffee (civet and non-civet) and two different particle sizes (212 and 500 µm) were prepared. Spectral data was acquired using NIR spectrometer equipped with an integrating sphere for diffuse reflectance measurement. A discrimination method based on PLS-DA was conducted and the influence of different particle size on the performance of PLS-DA was investigated. In explicit method, we add directly the particle size as predicted variable results in an X block containing only the NIR spectra and a Y block containing the particle size and type of coffee. The explicit inclusion of the particle size into the calibration model is expected to improve the accuracy of type of coffee determination. The result shows that using explicit method the quality of the developed calibration model for type of coffee determination is a little bit superior with coefficient of determination (R2) = 0.99 and root mean square error of cross-validation (RMSECV) = 0.041. The performance of the PLS2 calibration model for type of coffee determination with particle size compensation was quite good and able to predict the type of coffee in two different particle sizes with relatively high R2 pred values. The prediction also resulted in low bias and RMSEP values.
NASA Astrophysics Data System (ADS)
Singleton, Adrian A.; Schmidt, Amanda H.; Bierman, Paul R.; Rood, Dylan H.; Neilson, Thomas B.; Greene, Emily Sophie; Bower, Jennifer A.; Perdrial, Nicolas
2017-01-01
Grain-size dependencies in fallout radionuclide activity have been attributed to either increase in specific surface area in finer grain sizes or differing mineralogical abundances in different grain sizes. Here, we consider a third possibility, that the concentration and composition of grain coatings, where fallout radionuclides reside, controls their activity in fluvial sediment. We evaluated these three possible explanations in two experiments: (1) we examined the effect of sediment grain size, mineralogy, and composition of the acid-extractable materials on the distribution of 7Be, 10Be, 137Cs, and unsupported 210Pb in detrital sediment samples collected from rivers in China and the United States, and (2) we periodically monitored 7Be, 137Cs, and 210Pb retention in samples of known composition exposed to natural fallout in Ohio, USA for 294 days. Acid-extractable materials (made up predominately of Fe, Mn, Al, and Ca from secondary minerals and grain coatings produced during pedogenesis) are positively related to the abundance of fallout radionuclides in our sediment samples. Grain-size dependency of fallout radionuclide concentrations was significant in detrital sediment samples, but not in samples exposed to fallout under controlled conditions. Mineralogy had a large effect on 7Be and 210Pb retention in samples exposed to fallout, suggesting that sieving sediments to a single grain size or using specific surface area-based correction terms may not completely control for preferential distribution of these nuclides. We conclude that time-dependent geochemical, pedogenic, and sedimentary processes together result in the observed differences in nuclide distribution between different grain sizes and substrate compositions. These findings likely explain variability of measured nuclide activities in river networks that exceeds the variability introduced by analytical techniques as well as spatial and temporal differences in erosion rates and processes. In short, we suggest that presence and amount of pedogenic grain coatings is more important than either specific surface area or surface charge in setting the distribution of fallout radionuclides.
Li, Huili; Ostermann, Anne; Karunarathna, Samantha C; Xu, Jianchu; Hyde, Kevin D; Mortimer, Peter E
2018-07-01
The species-area relationship is an important factor in the study of species diversity, conservation biology, and landscape ecology. A deeper understanding of this relationship is necessary, in order to provide recommendations on how to improve the quality of data collection on macrofungal diversity in different land use systems in future studies, a systematic assessment of methodological parameters, in particular optimal plot sizes. The species-area relationship of macrofungi in tropical and temperate climatic zones and four different land use systems were investigated by determining the macrofungal species richness in plot sizes ranging from 100 m 2 to 10 000 m 2 over two sampling seasons. We found that the effect of plot size on recorded species richness significantly differed between land use systems with the exception of monoculture systems. For both climate zones, land use system needs to be considered when determining optimal plot size. Using an optimal plot size was more important than temporal replication (over two sampling seasons) in accurately recording species richness. Copyright © 2018 British Mycological Society. Published by Elsevier Ltd. All rights reserved.
Image analysis of representative food structures: application of the bootstrap method.
Ramírez, Cristian; Germain, Juan C; Aguilera, José M
2009-08-01
Images (for example, photomicrographs) are routinely used as qualitative evidence of the microstructure of foods. In quantitative image analysis it is important to estimate the area (or volume) to be sampled, the field of view, and the resolution. The bootstrap method is proposed to estimate the size of the sampling area as a function of the coefficient of variation (CV(Bn)) and standard error (SE(Bn)) of the bootstrap taking sub-areas of different sizes. The bootstrap method was applied to simulated and real structures (apple tissue). For simulated structures, 10 computer-generated images were constructed containing 225 black circles (elements) and different coefficient of variation (CV(image)). For apple tissue, 8 images of apple tissue containing cellular cavities with different CV(image) were analyzed. Results confirmed that for simulated and real structures, increasing the size of the sampling area decreased the CV(Bn) and SE(Bn). Furthermore, there was a linear relationship between the CV(image) and CV(Bn) (.) For example, to obtain a CV(Bn) = 0.10 in an image with CV(image) = 0.60, a sampling area of 400 x 400 pixels (11% of whole image) was required, whereas if CV(image) = 1.46, a sampling area of 1000 x 100 pixels (69% of whole image) became necessary. This suggests that a large-size dispersion of element sizes in an image requires increasingly larger sampling areas or a larger number of images.
Chow, Jeffrey T Y; Turkstra, Timothy P; Yim, Edmund; Jones, Philip M
2018-06-01
Although every randomized clinical trial (RCT) needs participants, determining the ideal number of participants that balances limited resources and the ability to detect a real effect is difficult. Focussing on two-arm, parallel group, superiority RCTs published in six general anesthesiology journals, the objective of this study was to compare the quality of sample size calculations for RCTs published in 2010 vs 2016. Each RCT's full text was searched for the presence of a sample size calculation, and the assumptions made by the investigators were compared with the actual values observed in the results. Analyses were only performed for sample size calculations that were amenable to replication, defined as using a clearly identified outcome that was continuous or binary in a standard sample size calculation procedure. The percentage of RCTs reporting all sample size calculation assumptions increased from 51% in 2010 to 84% in 2016. The difference between the values observed in the study and the expected values used for the sample size calculation for most RCTs was usually > 10% of the expected value, with negligible improvement from 2010 to 2016. While the reporting of sample size calculations improved from 2010 to 2016, the expected values in these sample size calculations often assumed effect sizes larger than those actually observed in the study. Since overly optimistic assumptions may systematically lead to underpowered RCTs, improvements in how to calculate and report sample sizes in anesthesiology research are needed.
NASA Astrophysics Data System (ADS)
Weinkauf, Manuel F. G.; Milker, Yvonne
2018-05-01
Benthic Foraminifera assemblages are employed for past environmental reconstructions, as well as for biomonitoring studies in recent environments. Despite their established status for such applications, and existing protocols for sample treatment, not all studies using benthic Foraminifera employ the same methodology. For instance, there is no broad practical consensus whether to use the >125 µm or >150 µm size fraction for benthic foraminiferal assemblage analyses. Here, we use early Pleistocene material from the Pefka E section on the Island of Rhodes (Greece), which has been counted in both size fractions, to investigate whether a 25 µm difference in the counted fraction is already sufficient to have an impact on ecological studies. We analysed the influence of the difference in size fraction on studies of biodiversity as well as multivariate assemblage analyses of the sample material. We found that for both types of studies, the general trends remain the same regardless of the chosen size fraction, but in detail significant differences emerge which are not consistently distributed between samples. Studies which require a high degree of precision can thus not compare results from analyses that used different size fractions, and the inconsistent distribution of differences makes it impossible to develop corrections for this issue. We therefore advocate the consistent use of the >125 µm size fraction for benthic foraminiferal studies in the future.
Meta-analysis of genome-wide association from genomic prediction models
USDA-ARS?s Scientific Manuscript database
A limitation of many genome-wide association studies (GWA) in animal breeding is that there are many loci with small effect sizes; thus, larger sample sizes (N) are required to guarantee suitable power of detection. To increase sample size, results from different GWA can be combined in a meta-analys...
How large a training set is needed to develop a classifier for microarray data?
Dobbin, Kevin K; Zhao, Yingdong; Simon, Richard M
2008-01-01
A common goal of gene expression microarray studies is the development of a classifier that can be used to divide patients into groups with different prognoses, or with different expected responses to a therapy. These types of classifiers are developed on a training set, which is the set of samples used to train a classifier. The question of how many samples are needed in the training set to produce a good classifier from high-dimensional microarray data is challenging. We present a model-based approach to determining the sample size required to adequately train a classifier. It is shown that sample size can be determined from three quantities: standardized fold change, class prevalence, and number of genes or features on the arrays. Numerous examples and important experimental design issues are discussed. The method is adapted to address ex post facto determination of whether the size of a training set used to develop a classifier was adequate. An interactive web site for performing the sample size calculations is provided. We showed that sample size calculations for classifier development from high-dimensional microarray data are feasible, discussed numerous important considerations, and presented examples.
Hattori, Shohei; Savarino, Joel; Kamezaki, Kazuki; Ishino, Sakiko; Dyckmans, Jens; Fujinawa, Tamaki; Caillon, Nicolas; Barbero, Albane; Mukotaka, Arata; Toyoda, Sakae; Well, Reinhard; Yoshida, Naohiro
2016-12-30
Triple oxygen and nitrogen isotope ratios in nitrate are powerful tools for assessing atmospheric nitrate formation pathways and their contribution to ecosystems. N 2 O decomposition using microwave-induced plasma (MIP) has been used only for measurements of oxygen isotopes to date, but it is also possible to measure nitrogen isotopes during the same analytical run. The main improvements to a previous system are (i) an automated distribution system of nitrate to the bacterial medium, (ii) N 2 O separation by gas chromatography before N 2 O decomposition using the MIP, (iii) use of a corundum tube for microwave discharge, and (iv) development of an automated system for isotopic measurements. Three nitrate standards with sample sizes of 60, 80, 100, and 120 nmol were measured to investigate the sample size dependence of the isotope measurements. The δ 17 O, δ 18 O, and Δ 17 O values increased with increasing sample size, although the δ 15 N value showed no significant size dependency. Different calibration slopes and intercepts were obtained with different sample amounts. The slopes and intercepts for the regression lines in different sample amounts were dependent on sample size, indicating that the extent of oxygen exchange is also dependent on sample size. The sample-size-dependent slopes and intercepts were fitted using natural log (ln) regression curves, and the slopes and intercepts can be estimated to apply to any sample size corrections. When using 100 nmol samples, the standard deviations of residuals from the regression lines for this system were 0.5‰, 0.3‰, and 0.1‰, respectively, for the δ 18 O, Δ 17 O, and δ 15 N values, results that are not inferior to those from other systems using gold tube or gold wire. An automated system was developed to measure triple oxygen and nitrogen isotopes in nitrate using N 2 O decomposition by MIP. This system enables us to measure both triple oxygen and nitrogen isotopes in nitrate with comparable precision and sample throughput (23 min per sample on average), and minimal manual treatment. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Heo, Moonseong; Litwin, Alain H; Blackstock, Oni; Kim, Namhee; Arnsten, Julia H
2017-02-01
We derived sample size formulae for detecting main effects in group-based randomized clinical trials with different levels of data hierarchy between experimental and control arms. Such designs are necessary when experimental interventions need to be administered to groups of subjects whereas control conditions need to be administered to individual subjects. This type of trial, often referred to as a partially nested or partially clustered design, has been implemented for management of chronic diseases such as diabetes and is beginning to emerge more commonly in wider clinical settings. Depending on the research setting, the level of hierarchy of data structure for the experimental arm can be three or two, whereas that for the control arm is two or one. Such different levels of data hierarchy assume correlation structures of outcomes that are different between arms, regardless of whether research settings require two or three level data structure for the experimental arm. Therefore, the different correlations should be taken into account for statistical modeling and for sample size determinations. To this end, we considered mixed-effects linear models with different correlation structures between experimental and control arms to theoretically derive and empirically validate the sample size formulae with simulation studies.
Standardized mean differences cause funnel plot distortion in publication bias assessments.
Zwetsloot, Peter-Paul; Van Der Naald, Mira; Sena, Emily S; Howells, David W; IntHout, Joanna; De Groot, Joris Ah; Chamuleau, Steven Aj; MacLeod, Malcolm R; Wever, Kimberley E
2017-09-08
Meta-analyses are increasingly used for synthesis of evidence from biomedical research, and often include an assessment of publication bias based on visual or analytical detection of asymmetry in funnel plots. We studied the influence of different normalisation approaches, sample size and intervention effects on funnel plot asymmetry, using empirical datasets and illustrative simulations. We found that funnel plots of the Standardized Mean Difference (SMD) plotted against the standard error (SE) are susceptible to distortion, leading to overestimation of the existence and extent of publication bias. Distortion was more severe when the primary studies had a small sample size and when an intervention effect was present. We show that using the Normalised Mean Difference measure as effect size (when possible), or plotting the SMD against a sample size-based precision estimate, are more reliable alternatives. We conclude that funnel plots using the SMD in combination with the SE are unsuitable for publication bias assessments and can lead to false-positive results.
Standardized mean differences cause funnel plot distortion in publication bias assessments
Van Der Naald, Mira; Sena, Emily S; Howells, David W; IntHout, Joanna; De Groot, Joris AH; Chamuleau, Steven AJ; MacLeod, Malcolm R
2017-01-01
Meta-analyses are increasingly used for synthesis of evidence from biomedical research, and often include an assessment of publication bias based on visual or analytical detection of asymmetry in funnel plots. We studied the influence of different normalisation approaches, sample size and intervention effects on funnel plot asymmetry, using empirical datasets and illustrative simulations. We found that funnel plots of the Standardized Mean Difference (SMD) plotted against the standard error (SE) are susceptible to distortion, leading to overestimation of the existence and extent of publication bias. Distortion was more severe when the primary studies had a small sample size and when an intervention effect was present. We show that using the Normalised Mean Difference measure as effect size (when possible), or plotting the SMD against a sample size-based precision estimate, are more reliable alternatives. We conclude that funnel plots using the SMD in combination with the SE are unsuitable for publication bias assessments and can lead to false-positive results. PMID:28884685
NASA Astrophysics Data System (ADS)
Willie, Jacob; Petre, Charles-Albert; Tagg, Nikki; Lens, Luc
2012-11-01
Data from forest herbaceous plants in a site of known species richness in Cameroon were used to test the performance of rarefaction and eight species richness estimators (ACE, ICE, Chao1, Chao2, Jack1, Jack2, Bootstrap and MM). Bias, accuracy, precision and sensitivity to patchiness and sample grain size were the evaluation criteria. An evaluation of the effects of sampling effort and patchiness on diversity estimation is also provided. Stems were identified and counted in linear series of 1-m2 contiguous square plots distributed in six habitat types. Initially, 500 plots were sampled in each habitat type. The sampling process was monitored using rarefaction and a set of richness estimator curves. Curves from the first dataset suggested adequate sampling in riparian forest only. Additional plots ranging from 523 to 2143 were subsequently added in the undersampled habitats until most of the curves stabilized. Jack1 and ICE, the non-parametric richness estimators, performed better, being more accurate and less sensitive to patchiness and sample grain size, and significantly reducing biases that could not be detected by rarefaction and other estimators. This study confirms the usefulness of non-parametric incidence-based estimators, and recommends Jack1 or ICE alongside rarefaction while describing taxon richness and comparing results across areas sampled using similar or different grain sizes. As patchiness varied across habitat types, accurate estimations of diversity did not require the same number of plots. The number of samples needed to fully capture diversity is not necessarily the same across habitats, and can only be known when taxon sampling curves have indicated adequate sampling. Differences in observed species richness between habitats were generally due to differences in patchiness, except between two habitats where they resulted from differences in abundance. We suggest that communities should first be sampled thoroughly using appropriate taxon sampling curves before explaining differences in diversity.
Heidel, R Eric
2016-01-01
Statistical power is the ability to detect a significant effect, given that the effect actually exists in a population. Like most statistical concepts, statistical power tends to induce cognitive dissonance in hepatology researchers. However, planning for statistical power by an a priori sample size calculation is of paramount importance when designing a research study. There are five specific empirical components that make up an a priori sample size calculation: the scale of measurement of the outcome, the research design, the magnitude of the effect size, the variance of the effect size, and the sample size. A framework grounded in the phenomenon of isomorphism, or interdependencies amongst different constructs with similar forms, will be presented to understand the isomorphic effects of decisions made on each of the five aforementioned components of statistical power.
Xu, Zhenqiang; Yao, Maosheng
2013-05-01
Increasing evidences show that inhalation of indoor bioaerosols has caused numerous adverse health effects and diseases. However, the bioaerosol size distribution, composition, and concentration level, representing different inhalation risks, could vary with different living environments. The six-stage Andersen sampler is designed to simulate the sampling of different human lung regions. Here, the sampler was used in investigating the bioaerosol exposure in six different environments (student dorm, hospital, laboratory, hotel room, dining hall, and outdoor environment) in Beijing. During the sampling, the Andersen sampler was operated for 30 min for each sample, and three independent experiments were performed for each of the environments. The air samples collected onto each of the six stages of the sampler were incubated on agar plates directly at 26 °C, and the colony forming units (CFU) were manually counted and statistically corrected. In addition, the developed CFUs were washed off the agar plates and subjected to polymerase chain reaction (PCR)-denaturing gradient gel electrophoresis (DGGE) for diversity analysis. Results revealed that for most environments investigated, the culturable bacterial aerosol concentrations were higher than those of culturable fungal aerosols. The culturable bacterial and fungal aerosol fractions, concentration, size distribution, and diversity were shown to vary significantly with the sampling environments. PCR-DGGE analysis indicated that different environments had different culturable bacterial aerosol compositions as revealed by distinct gel band patterns. For most environments tested, larger (>3 μm) culturable bacterial aerosols with a skewed size distribution were shown to prevail, accounting for more than 60 %, while for culturable fungal aerosols with a normal size distribution, those 2.1-4.7 μm dominated, accounting for 20-40 %. Alternaria, Cladosporium, Chaetomium, and Aspergillus were found abundant in most environments studied here. Viable microbial load per unit of particulate matter was also shown to vary significantly with the sampling environments. The results from this study suggested that different environments even with similar levels of total microbial culturable aerosol concentrations could present different inhalation risks due to different bioaerosol particle size distribution and composition. This work fills literature gaps regarding bioaerosol size and composition-based exposure risks in different human dwellings in contrast to a vast body of total bioaerosol levels.
NASA Astrophysics Data System (ADS)
Gholizadeh, Ahmad
2018-04-01
In the present work, the influence of different sintering atmospheres and temperatures on physical properties of the Cu0.5Zn0.5Fe2O4 nanoparticles including the redistribution of Zn2+ and Fe3+ ions, the oxidation of Fe atoms in the lattice, crystallite sizes, IR bands, saturation magnetization and magnetic core sizes have been investigated. The fitting of XRD patterns by using Fullprof program and also FT-IR measurement show the formation of a cubic structure with no presence of impurity phase for all the samples. The unit cell parameter of the samples sintered at the air- and inert-ambient atmospheres trend to decrease with sintering temperature, but for the samples sintered under carbon monoxide-ambient atmosphere increase. The magnetization curves versus the applied magnetic field, indicate different behaviour for the samples sintered at 700 °C with the respect to the samples sintered at 300 °C. Also, the saturation magnetization increases with the sintering temperature and reach a maximum 61.68 emu/g in the sample sintered under reducing atmosphere at 600 °C. The magnetic particle size distributions of samples have been calculated by fitting the M-H curves with the size distributed Langevin function. The results obtained from the XRD and FTIR measurements suggest that the magnetic core size has the dominant effect in variation of the saturation magnetization of the samples.
NASA Astrophysics Data System (ADS)
Flipon, B.; de la Cruz, L. Garcia; Hug, E.; Keller, C.; Barbe, F.
2017-10-01
Samples of 316L austenitic stainless steel with bimodal grain size distributions are elaborated using two distinct routes. The first one is based on powder metallurgy using spark plasma sintering of two powders with different particle sizes. The second route applies the reverse-annealing method: it consists in inducing martensitic phase transformation by plastic strain and further annealing in order to obtain two austenitic grain populations with different sizes. Microstructural analy ses reveal that both methods are suitable to generate significative grain size contrast and to control this contrast according to the elaboration conditions. Mechanical properties under tension are then characterized for different grain size distributions. Crystal plasticity finite element modelling is further applied in a configuration of bimodal distribution to analyse the role played by coarse grains within a matrix of fine grains, considering not only their volume fraction but also their spatial arrangement.
NASA Astrophysics Data System (ADS)
Wilbourn, E.; Thornton, D.; Brooks, S. D.; Graff, J.
2016-12-01
The role of marine aerosols as ice nucleating particles is currently poorly understood. Despite growing interest, there are remarkably few ice nucleation measurements on representative marine samples. Here we present results of heterogeneous ice nucleation from laboratory studies and in-situ air and sea water samples collected during NAAMES (North Atlantic Aerosol and Marine Ecosystems Study). Thalassiosira weissflogii (CCMP 1051) was grown under controlled conditions in batch cultures and the ice nucleating activity depended on the growth phase of the cultures. Immersion freezing temperatures of the lab-grown diatoms were determined daily using a custom ice nucleation apparatus cooled at a set rate. Our results show that the age of the culture had a significant impact on ice nucleation temperature, with samples in stationary phase causing nucleation at -19.9 °C, approximately nine degrees warmer than the freezing temperature during exponential growth phase. Field samples gathered during the NAAMES II cruise in May 2016 were also tested for ice nucleating ability. Two types of samples were gathered. Firstly, whole cells were fractionated by size from surface seawater using a BD Biosciences Influx Cell Sorter (BD BS ISD). Secondly, aerosols were generated using the SeaSweep and subsequently size-selected using a PIXE Cascade Impactor. Samples were tested for the presence of ice nucleating particles (INP) using the technique described above. There were significant differences in the freezing temperature of the different samples; of the three sample types the lab-grown cultures tested during stationary phase froze at the warmest temperatures, followed by the SeaSweep samples (-25.6 °C) and the size-fractionated cell samples (-31.3 °C). Differences in ice nucleation ability may be due to size differences between the INP, differences in chemical composition of the sample, or some combination of these two factors. Results will be presented and atmospheric implications discussed.
Steigen, Terje K; Claudio, Cheryl; Abbott, David; Schulzer, Michael; Burton, Jeff; Tymchak, Wayne; Buller, Christopher E; John Mancini, G B
2008-06-01
To assess reproducibility of core laboratory performance and impact on sample size calculations. Little information exists about overall reproducibility of core laboratories in contradistinction to performance of individual technicians. Also, qualitative parameters are being adjudicated increasingly as either primary or secondary end-points. The comparative impact of using diverse indexes on sample sizes has not been previously reported. We compared initial and repeat assessments of five quantitative parameters [e.g., minimum lumen diameter (MLD), ejection fraction (EF), etc.] and six qualitative parameters [e.g., TIMI myocardial perfusion grade (TMPG) or thrombus grade (TTG), etc.], as performed by differing technicians and separated by a year or more. Sample sizes were calculated from these results. TMPG and TTG were also adjudicated by a second core laboratory. MLD and EF were the most reproducible, yielding the smallest sample size calculations, whereas percent diameter stenosis and centerline wall motion require substantially larger trials. Of the qualitative parameters, all except TIMI flow grade gave reproducibility characteristics yielding sample sizes of many 100's of patients. Reproducibility of TMPG and TTG was only moderately good both within and between core laboratories, underscoring an intrinsic difficulty in assessing these. Core laboratories can be shown to provide reproducibility performance that is comparable to performance commonly ascribed to individual technicians. The differences in reproducibility yield huge differences in sample size when comparing quantitative and qualitative parameters. TMPG and TTG are intrinsically difficult to assess and conclusions based on these parameters should arise only from very large trials.
Sample size of the reference sample in a case-augmented study.
Ghosh, Palash; Dewanji, Anup
2017-05-01
The case-augmented study, in which a case sample is augmented with a reference (random) sample from the source population with only covariates information known, is becoming popular in different areas of applied science such as pharmacovigilance, ecology, and econometrics. In general, the case sample is available from some source (for example, hospital database, case registry, etc.); however, the reference sample is required to be drawn from the corresponding source population. The required minimum size of the reference sample is an important issue in this regard. In this work, we address the minimum sample size calculation and discuss related issues. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Sample size considerations when groups are the appropriate unit of analyses
Sadler, Georgia Robins; Ko, Celine Marie; Alisangco, Jennifer; Rosbrook, Bradley P.; Miller, Eric; Fullerton, Judith
2007-01-01
This paper discusses issues to be considered by nurse researchers when groups should be used as a unit of randomization. Advantages and disadvantages are presented, with statistical calculations needed to determine effective sample size. Examples of these concepts are presented using data from the Black Cosmetologists Promoting Health Program. Different hypothetical scenarios and their impact on sample size are presented. Given the complexity of calculating sample size when using groups as a unit of randomization, it’s advantageous for researchers to work closely with statisticians when designing and implementing studies that anticipate the use of groups as the unit of randomization. PMID:17693219
Wason, James M. S.; Mander, Adrian P.
2012-01-01
Two-stage designs are commonly used for Phase II trials. Optimal two-stage designs have the lowest expected sample size for a specific treatment effect, for example, the null value, but can perform poorly if the true treatment effect differs. Here we introduce a design for continuous treatment responses that minimizes the maximum expected sample size across all possible treatment effects. The proposed design performs well for a wider range of treatment effects and so is useful for Phase II trials. We compare the design to a previously used optimal design and show it has superior expected sample size properties. PMID:22651118
A USANS/SANS study of the accessibility of pores in the Barnett Shale to methane and water
Ruppert, Leslie F.; Sakurovs, Richard; Blach, Tomasz P.; He, Lilin; Melnichenko, Yuri B.; Mildner, David F.; Alcantar-Lopez, Leo
2013-01-01
Shale is an increasingly important source of natural gas in the United States. The gas is held in fine pores that need to be accessed by horizontal drilling and hydrofracturing techniques. Understanding the nature of the pores may provide clues to making gas extraction more efficient. We have investigated two Mississippian Barnett Shale samples, combining small-angle neutron scattering (SANS) and ultrasmall-angle neutron scattering (USANS) to determine the pore size distribution of the shale over the size range 10 nm to 10 μm. By adding deuterated methane (CD4) and, separately, deuterated water (D2O) to the shale, we have identified the fraction of pores that are accessible to these compounds over this size range. The total pore size distribution is essentially identical for the two samples. At pore sizes >250 nm, >85% of the pores in both samples are accessible to both CD4 and D2O. However, differences in accessibility to CD4 are observed in the smaller pore sizes (~25 nm). In one sample, CD4 penetrated the smallest pores as effectively as it did the larger ones. In the other sample, less than 70% of the smallest pores (4, but they were still largely penetrable by water, suggesting that small-scale heterogeneities in methane accessibility occur in the shale samples even though the total porosity does not differ. An additional study investigating the dependence of scattered intensity with pressure of CD4 allows for an accurate estimation of the pressure at which the scattered intensity is at a minimum. This study provides information about the composition of the material immediately surrounding the pores. Most of the accessible (open) pores in the 25 nm size range can be associated with either mineral matter or high reflectance organic material. However, a complementary scanning electron microscopy investigation shows that most of the pores in these shale samples are contained in the organic components. The neutron scattering results indicate that the pores are not equally proportioned in the different constituents within the shale. There is some indication from the SANS results that the composition of the pore-containing material varies with pore size; the pore size distribution associated with mineral matter is different from that associated with organic phases.
Opsahl, Stephen P.; Crow, Cassi L.
2014-01-01
During collection of streambed-sediment samples, additional samples from a subset of three sites (the SAR Elmendorf, SAR 72, and SAR McFaddin sites) were processed by using a 63-µm sieve on one aliquot and a 2-mm sieve on a second aliquot for PAH and n-alkane analyses. The purpose of analyzing PAHs and n-alkanes on a sample containing sand, silt, and clay versus a sample containing only silt and clay was to provide data that could be used to determine if these organic constituents had a greater affinity for silt- and clay-sized particles relative to sand-sized particles. The greater concentrations of PAHs in the <63-μm size-fraction samples at all three of these sites are consistent with a greater percentage of binding sites associated with fine-grained (<63 μm) sediment versus coarse-grained (<2 mm) sediment. The larger difference in total PAHs between the <2-mm and <63-μm size-fraction samples at the SAR Elmendorf site might be related to the large percentage of sand in the <2-mm size-fraction sample which was absent in the <63-μm size-fraction sample. In contrast, the <2-mm size-fraction sample collected from the SAR McFaddin site contained very little sand and was similar in particle-size composition to the <63-μm size-fraction sample.
Considerations in Forest Growth Estimation Between Two Measurements of Mapped Forest Inventory Plots
Michael T. Thompson
2006-01-01
Several aspects of the enhanced Forest Inventory and Analysis (FIA) program?s national plot design complicate change estimation. The design incorporates up to three separate plot sizes (microplot, subplot, and macroplot) to sample trees of different sizes. Because multiple plot sizes are involved, change estimators designed for polyareal plot sampling, such as those...
NASA Astrophysics Data System (ADS)
Roslindar Yaziz, Siti; Zakaria, Roslinazairimah; Hura Ahmad, Maizah
2017-09-01
The model of Box-Jenkins - GARCH has been shown to be a promising tool for forecasting higher volatile time series. In this study, the framework of determining the optimal sample size using Box-Jenkins model with GARCH is proposed for practical application in analysing and forecasting higher volatile data. The proposed framework is employed to daily world gold price series from year 1971 to 2013. The data is divided into 12 different sample sizes (from 30 to 10200). Each sample is tested using different combination of the hybrid Box-Jenkins - GARCH model. Our study shows that the optimal sample size to forecast gold price using the framework of the hybrid model is 1250 data of 5-year sample. Hence, the empirical results of model selection criteria and 1-step-ahead forecasting evaluations suggest that the latest 12.25% (5-year data) of 10200 data is sufficient enough to be employed in the model of Box-Jenkins - GARCH with similar forecasting performance as by using 41-year data.
Olivares, M; Larrañaga, A; Irazola, M; Sarmiento, A; Murelaga, X; Etxebarria, N
2012-08-30
The determination of crystal size of chert samples can provide suitable information about the raw material used for the manufacture of archeological items. X-ray diffraction (XRD) has been widely used for this purpose in several scientific areas. However, the historical value of archeological pieces makes this procedure sometimes unfeasible and thus, non-invasive new analytical approaches are required. In this sense, a new method was developed relating the crystal size obtained by means of XRD and infrared spectroscopy (IR) using partial least squares regression. The IR spectra collected from a large amount of different geological chert samples of archeological use were pre-processed following different treatments (i.e., derivatization or sample-wise normalization) to obtain the best regression model. The full cross-validation was satisfactorily validated using real samples and the experimental root mean standard error of precision value was 165 Å whereas the average precision of the estimated size value was 3%. The features of infrared bands were also evaluated in order to know the background of the prediction ability. In the studied case, the variance in the model was associated to the differences in the characteristic stretching and bending infrared bands of SiO(2). Based on this fact, it would be feasible to estimate the crystal size if it is built beforehand a chemometric model relating the size measured by standard methods and the IR spectra. Copyright © 2012 Elsevier B.V. All rights reserved.
Simple and multiple linear regression: sample size considerations.
Hanley, James A
2016-11-01
The suggested "two subjects per variable" (2SPV) rule of thumb in the Austin and Steyerberg article is a chance to bring out some long-established and quite intuitive sample size considerations for both simple and multiple linear regression. This article distinguishes two of the major uses of regression models that imply very different sample size considerations, neither served well by the 2SPV rule. The first is etiological research, which contrasts mean Y levels at differing "exposure" (X) values and thus tends to focus on a single regression coefficient, possibly adjusted for confounders. The second research genre guides clinical practice. It addresses Y levels for individuals with different covariate patterns or "profiles." It focuses on the profile-specific (mean) Y levels themselves, estimating them via linear compounds of regression coefficients and covariates. By drawing on long-established closed-form variance formulae that lie beneath the standard errors in multiple regression, and by rearranging them for heuristic purposes, one arrives at quite intuitive sample size considerations for both research genres. Copyright © 2016 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Matsumoto, David; Grissom, Robert J.; Dinnel, Dale L.
2001-01-01
Recommends four measures of cultural effect size appropriate for cross-cultural research (standardized difference between two sample means, probabilistic superiority effect size measure, Cohen's U1, and point biserial correlation), demonstrating their efficacy on two data sets from previously published studies and arguing for their use in future…
Mächtle, W
1999-01-01
Sedimentation velocity is a powerful tool for the analysis of complex solutions of macromolecules. However, sample turbidity imposes an upper limit to the size of molecular complexes currently amenable to such analysis. Furthermore, the breadth of the particle size distribution, combined with possible variations in the density of different particles, makes it difficult to analyze extremely complex mixtures. These same problems are faced in the polymer industry, where dispersions of latices, pigments, lacquers, and emulsions must be characterized. There is a rich history of methods developed for the polymer industry finding use in the biochemical sciences. Two such methods are presented. These use analytical ultracentrifugation to determine the density and size distributions for submicron-sized particles. Both methods rely on Stokes' equations to estimate particle size and density, whereas turbidity, corrected using Mie's theory, provides the concentration measurement. The first method uses the sedimentation time in dispersion media of different densities to evaluate the particle density and size distribution. This method works provided the sample is chemically homogeneous. The second method splices together data gathered at different sample concentrations, thus permitting the high-resolution determination of the size distribution of particle diameters ranging from 10 to 3000 nm. By increasing the rotor speed exponentially from 0 to 40,000 rpm over a 1-h period, size distributions may be measured for extremely broadly distributed dispersions. Presented here is a short history of particle size distribution analysis using the ultracentrifuge, along with a description of the newest experimental methods. Several applications of the methods are provided that demonstrate the breadth of its utility, including extensions to samples containing nonspherical and chromophoric particles. PMID:9916040
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jomekian, A.; Faculty of Chemical Engineering, Iran University of Science and Technology; Behbahani, R.M., E-mail: behbahani@put.ac.ir
Ultra porous ZIF-8 particles synthesized using PEO/PA6 based poly(ether-block-amide) (Pebax 1657) as structure directing agent. Structural properties of ZIF-8 samples prepared under different synthesis parameters were investigated by laser particle size analysis, XRD, N{sub 2} adsorption analysis, BJH and BET tests. The overall results showed that: (1) The mean pore size of all ZIF-8 samples increased remarkably (from 0.34 nm to 1.1–2.5 nm) compared to conventionally synthesized ZIF-8 samples. (2) Exceptional BET surface area of 1869 m{sup 2}/g was obtained for a ZIF-8 sample with mean pore size of 2.5 nm. (3) Applying high concentrations of Pebax 1657 to themore » synthesis solution lead to higher surface area, larger pore size and smaller particle size for ZIF-8 samples. (4) Both, Increase in temperature and decrease in molar ratio of MeIM/Zn{sup 2+} had increasing effect on ZIF-8 particle size, pore size, pore volume, crystallinity and BET surface area of all investigated samples. - Highlights: • The pore size of ZIF-8 samples synthesized with Pebax 1657 increased remarkably. • The BET surface area of 1869 m{sup 2}/gr obtained for a ZIF-8 synthesized sample with Pebax. • Increase in temperature had increasing effect on textural properties of ZIF-8 samples. • Decrease in MeIM/Zn{sup 2+} had increasing effect on textural properties of ZIF-8 samples.« less
Blinded and unblinded internal pilot study designs for clinical trials with count data.
Schneider, Simon; Schmidli, Heinz; Friede, Tim
2013-07-01
Internal pilot studies are a popular design feature to address uncertainties in the sample size calculations caused by vague information on nuisance parameters. Despite their popularity, only very recently blinded sample size reestimation procedures for trials with count data were proposed and their properties systematically investigated. Although blinded procedures are favored by regulatory authorities, practical application is somewhat limited by fears that blinded procedures are prone to bias if the treatment effect was misspecified in the planning. Here, we compare unblinded and blinded procedures with respect to bias, error rates, and sample size distribution. We find that both procedures maintain the desired power and that the unblinded procedure is slightly liberal whereas the actual significance level of the blinded procedure is close to the nominal level. Furthermore, we show that in situations where uncertainty about the assumed treatment effect exists, the blinded estimator of the control event rate is biased in contrast to the unblinded estimator, which results in differences in mean sample sizes in favor of the unblinded procedure. However, these differences are rather small compared to the deviations of the mean sample sizes from the sample size required to detect the true, but unknown effect. We demonstrate that the variation of the sample size resulting from the blinded procedure is in many practically relevant situations considerably smaller than the one of the unblinded procedures. The methods are extended to overdispersed counts using a quasi-likelihood approach and are illustrated by trials in relapsing multiple sclerosis. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Overall, John E; Tonidandel, Scott; Starbuck, Robert R
2006-01-01
Recent contributions to the statistical literature have provided elegant model-based solutions to the problem of estimating sample sizes for testing the significance of differences in mean rates of change across repeated measures in controlled longitudinal studies with differentially correlated error and missing data due to dropouts. However, the mathematical complexity and model specificity of these solutions make them generally inaccessible to most applied researchers who actually design and undertake treatment evaluation research in psychiatry. In contrast, this article relies on a simple two-stage analysis in which dropout-weighted slope coefficients fitted to the available repeated measurements for each subject separately serve as the dependent variable for a familiar ANCOVA test of significance for differences in mean rates of change. This article is about how a sample of size that is estimated or calculated to provide desired power for testing that hypothesis without considering dropouts can be adjusted appropriately to take dropouts into account. Empirical results support the conclusion that, whatever reasonable level of power would be provided by a given sample size in the absence of dropouts, essentially the same power can be realized in the presence of dropouts simply by adding to the original dropout-free sample size the number of subjects who would be expected to drop from a sample of that original size under conditions of the proposed study.
Using sieving and pretreatment to separate plastics during end-of-life vehicle recycling.
Stagner, Jacqueline A; Sagan, Barsha; Tam, Edwin Kl
2013-09-01
Plastics continue to be a challenge for recovering materials at the end-of-life for vehicles. However, it may be possible to improve the recovery of plastics by exploiting material characteristics, such as shape, or by altering their behavior, such as through temperature changes, in relation to recovery processes and handling. Samples of a 2009 Dodge Challenger front fascia were shredded in a laboratory-scale hammer mill shredder. A 2 × 2 factorial design study was performed to determine the effect of sample shape (flat versus curved) and sample temperature (room temperature versus cryogenic temperature) on the size of the particles exiting from the shredder. It was determined that sample shape does not affect the particle size; however, sample temperature does affect the particle size. At cryogenic temperatures, the distribution of particle sizes is much narrower than at room temperature. Having a more uniform particle size could make recovery of plastic particles, such as these more efficient during the recycling of end-of-life vehicles. Samples of Chrysler minivan headlights were also shredded at room temperature and at cryogenic temperatures. The size of the particles of the two different plastics in the headlights is statistically different both at room temperature and at cryogenic temperature, and the particles are distributed narrowly. The research suggests that incremental changes in end-of-life vehicle processing could be effective in aiding materials recovery.
NASA Astrophysics Data System (ADS)
Startsev, V. O.; Il'ichev, A. V.
2018-05-01
The effect of mechanical impact energy on the sorption and diffusion of moisture in polymer composite samples on variation of their sizes was investigated. Square samples, with sides of 40, 60, 80, and 100 mm, made of a KMKU-2m-120.E0,1 carbon-fiber and KMKS-2m.120.T10 glass-fiber plastics with different resistances to calibrated impacts, were compared. Impact loading diagrams of the samples in relation to their sizes and impact energy were analyzed. It is shown that the moisture saturation and moisture diffusion coefficient of the impact-damaged materials can be modeled by Fick's second law with account of impact energy and sample sizes.
Analysis of $sup 239$Pu and $sup 241$Am in NAEG large-sized bovine samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Major, W.J.; Lee, K.D.; Wessman, R.A.
Methods are described for the analysis of environmental levels of $sup 239$Pu and $sup 241$Am in large-sized bovine samples. Special procedure modifications to overcome the complexities of sample preparation and analyses and special techniques employed to prepare and analyze different types of bovine samples, such as muscle, blood, liver, and bone are discussed. (CH)
Diao, Junshu; Chen, Zhao; Gong, Chao; Jiang, Xiuping
2015-09-01
This study investigated the survival of Escherichia coli O157:H7 and Salmonella Typhimurium in finished dairy compost with different particle sizes during storage as affected by moisture content and temperature under greenhouse conditions. The mixture of E. coli O157:H7 and S. Typhimurium strains was inoculated into the finished composts with moisture contents of 20, 30, and 40%, separately. The finished compost samples were then sieved into 3 different particle sizes (>1000, 500-1000, and <500 μm) and stored under greenhouse conditions. For compost samples with moisture contents of 20 and 30%, the average Salmonella reductions in compost samples with particle sizes of >1000, 500-1000, and <500 μm were 2.15, 2.27, and 2.47 log colony-forming units (CFU) g(-1) within 5 days of storage in summer, respectively, as compared with 1.60, 2.03, and 2.26 log CFU g(-1) in late fall, respectively, and 2.61, 3.33, and 3.67 log CFU g(-1) in winter, respectively. The average E. coli O157:H7 reductions in compost samples with particle sizes of >1000, 500-1000, and <500 μm were 1.98, 2.30, and 2.54 log CFU g(-1) within 5 days of storage in summer, respectively, as compared with 1.70, 2.56, and 2.90 log CFU g(-1) in winter, respectively. Our results revealed that both Salmonella and E. coli O157:H7 in compost samples with larger particle size survived better than those with smaller particle sizes, and the initial rapid moisture loss in compost may contribute to the fast inactivation of pathogens in the finished compost. For the same season, the pathogens in the compost samples with the same particle size survived much better at the initial moisture content of 20% compared to 40%.
NASA Astrophysics Data System (ADS)
Liu, Yichi; Liu, Debao; You, Chen; Chen, Minfang
2015-09-01
The aim of this study was to investigate the effect of grain size on the corrosion resistance of pure magnesium developed for biomedical applications. High-purity magnesium samples with different grain size were prepared by the cooling rate-controlled solidification. Electrochemical and immersion tests were employed to measure the corrosion resistance of pure magnesium with different grain size. The electrochemical polarization curves indicated that the corrosion susceptibility increased as the grain size decrease. However, the electrochemical impedance spectroscopy (EIS) and immersion tests indicated that the corrosion resistance of pure magnesium is improved as the grain size decreases. The improvement in the corrosion resistance is attributed to refine grain can produce more uniform and density film on the surface of sample.
Yang, Songshan; Cranford, James A; Jester, Jennifer M; Li, Runze; Zucker, Robert A; Buu, Anne
2017-02-28
This study proposes a time-varying effect model for examining group differences in trajectories of zero-inflated count outcomes. The motivating example demonstrates that this zero-inflated Poisson model allows investigators to study group differences in different aspects of substance use (e.g., the probability of abstinence and the quantity of alcohol use) simultaneously. The simulation study shows that the accuracy of estimation of trajectory functions improves as the sample size increases; the accuracy under equal group sizes is only higher when the sample size is small (100). In terms of the performance of the hypothesis testing, the type I error rates are close to their corresponding significance levels under all settings. Furthermore, the power increases as the alternative hypothesis deviates more from the null hypothesis, and the rate of this increasing trend is higher when the sample size is larger. Moreover, the hypothesis test for the group difference in the zero component tends to be less powerful than the test for the group difference in the Poisson component. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Harrell-Williams, Leigh; Wolfe, Edward W
2014-01-01
Previous research has investigated the influence of sample size, model misspecification, test length, ability distribution offset, and generating model on the likelihood ratio difference test in applications of item response models. This study extended that research to the evaluation of dimensionality using the multidimensional random coefficients multinomial logit model (MRCMLM). Logistic regression analysis of simulated data reveal that sample size and test length have a large effect on the capacity of the LR difference test to correctly identify unidimensionality, with shorter tests and smaller sample sizes leading to smaller Type I error rates. Higher levels of simulated misfit resulted in fewer incorrect decisions than data with no or little misfit. However, Type I error rates indicate that the likelihood ratio difference test is not suitable under any of the simulated conditions for evaluating dimensionality in applications of the MRCMLM.
NASA Astrophysics Data System (ADS)
Palihawadana Arachchige, Maheshika; Nemala, Humeshkar; Naik, Vaman; Naik, Ratna
Magnetic hyperthermia (MHT) has a great potential as a non-invasive cancer therapy technique. Specific absorption rate (SAR) which measures the efficiency of heat generation, mainly depends on magnetic properties of nanoparticles such as saturation magnetization (Ms) and magnetic anisotropy (K) which depend on the size and shape. Therefore, MHT applications of magnetic nanoparticles often require a controllable synthesis to achieve desirable magnetic properties. We have synthesized Fe3O4 nanoparticles using two different methods, co-precipitation (CP) and hydrothermal (HT) techniques to produce similar XRD crystallite size of 12 nm, and subsequently coated with dextran to prepare ferrofluids for MHT. However, TEM measurements show average particle sizes of 13.8 +/-3.6 nm and 14.6 +/-3.6 nm for HT and CP samples, implying the existence of an amorphous surface layer for both. The MHT data show the two samples have very different SAR values of 110 W/g (CP) and 40W/g (HT) at room temperature, although they have similar Ms of 70 +/-4 emu/g regardless of their different TEM sizes. We fitted the temperature dependent SAR using linear response theory to explain the observed results. CP sample shows a larger magnetic core with a narrow size distribution and a higher K value compared to that of HT sample.
NASA Astrophysics Data System (ADS)
Venero, I. M.; Mayol-Bracero, O. L.; Anderson, J. R.
2012-12-01
As part of the Puerto Rican African Dust and Cloud Study (PRADACS) and the Ice in Clouds Experiment - Tropical (ICE-T), we sampled giant airborne particles to study their elemental composition, morphology, and size distributions. Samples were collected in July 2011 during field measurements performed by NCAR's C-130 aircraft based on St Croix, U.S Virgin Island. The results presented here correspond to the measurements done during research flight #8 (RF8). Aerosol particles with Dp > 1 um were sampled with the Giant Nuclei Impactor and particles with Dp < 1 um were collected with the Wyoming Inlet. Collected particles were later analyzed using an automated scanning electron microscope (SEM) and manual observation by field emission SEM. We identified the chemical composition and morphology of major particle types in filter samples collected at different altitudes (e.g., 300 ft, 1000 ft, and 4500ft). Results from the flight upwind of Puerto Rico show that particles in the giant nuclei size range are dominated by sea salt. Samples collected at altitudes 300 ft and 1000 ft showed the highest number of sea salt particles and the samples collected at higher altitudes (> 4000 ft) showed the highest concentrations of clay material. HYSPLIT back trajectories for all samples showed that the low altitude samples initiated in the free troposphere in the Atlantic Ocean, which may account for the high sea salt content and that the source of the high altitude samples was closer to the Saharan - Sahel desert region and, therefore, these samples possibly had the influence of African dust. Size distribution results for quartz and unreacted sea-salt aerosols collected on the Giant Nuclei Impactor showed that sample RF08 - 12:05 UTM (300 ft) had the largest size value (mean = 2.936 μm) than all the other samples. Additional information was also obtained from the Wyoming Inlet present at the C - 130 aircraft which showed that size distribution results for all particles were smaller in size. The different mineral components of the dust have different size distributions so that a fractionation process could occur during transport. Also, the presence of supermicron sea salt at altitude is important for cloud processes.
A note on sample size calculation for mean comparisons based on noncentral t-statistics.
Chow, Shein-Chung; Shao, Jun; Wang, Hansheng
2002-11-01
One-sample and two-sample t-tests are commonly used in analyzing data from clinical trials in comparing mean responses from two drug products. During the planning stage of a clinical study, a crucial step is the sample size calculation, i.e., the determination of the number of subjects (patients) needed to achieve a desired power (e.g., 80%) for detecting a clinically meaningful difference in the mean drug responses. Based on noncentral t-distributions, we derive some sample size calculation formulas for testing equality, testing therapeutic noninferiority/superiority, and testing therapeutic equivalence, under the popular one-sample design, two-sample parallel design, and two-sample crossover design. Useful tables are constructed and some examples are given for illustration.
Got power? A systematic review of sample size adequacy in health professions education research.
Cook, David A; Hatala, Rose
2015-03-01
Many education research studies employ small samples, which in turn lowers statistical power. We re-analyzed the results of a meta-analysis of simulation-based education to determine study power across a range of effect sizes, and the smallest effect that could be plausibly excluded. We systematically searched multiple databases through May 2011, and included all studies evaluating simulation-based education for health professionals in comparison with no intervention or another simulation intervention. Reviewers working in duplicate abstracted information to calculate standardized mean differences (SMD's). We included 897 original research studies. Among the 627 no-intervention-comparison studies the median sample size was 25. Only two studies (0.3%) had ≥80% power to detect a small difference (SMD > 0.2 standard deviations) and 136 (22%) had power to detect a large difference (SMD > 0.8). 110 no-intervention-comparison studies failed to find a statistically significant difference, but none excluded a small difference and only 47 (43%) excluded a large difference. Among 297 studies comparing alternate simulation approaches the median sample size was 30. Only one study (0.3%) had ≥80% power to detect a small difference and 79 (27%) had power to detect a large difference. Of the 128 studies that did not detect a statistically significant effect, 4 (3%) excluded a small difference and 91 (71%) excluded a large difference. In conclusion, most education research studies are powered only to detect effects of large magnitude. For most studies that do not reach statistical significance, the possibility of large and important differences still exists.
Suspended sediments from upstream tributaries as the source of downstream river sites
NASA Astrophysics Data System (ADS)
Haddadchi, Arman; Olley, Jon
2014-05-01
Understanding the efficiency with which sediment eroded from different sources is transported to the catchment outlet is a key knowledge gap that is critical to our ability to accurately target and prioritise management actions to reduce sediment delivery. Sediment fingerprinting has proven to be an efficient approach to determine the sources of sediment. This study examines the suspended sediment sources from Emu Creek catchment, south eastern Queensland, Australia. In addition to collect suspended sediments from different sites of the streams after the confluence of tributaries and outlet of the catchment, time integrated suspended samples from upper tributaries were used as the source of sediment, instead of using hillslope and channel bank samples. Totally, 35 time-integrated samplers were used to compute the contribution of suspended sediments from different upstream waterways to the downstream sediment sites. Three size fractions of materials including fine sand (63-210 μm), silt (10-63 μm) and fine silt and clay (<10 μm) were used to find the effect of particle size on the contribution of upper sediments as the sources of sediment after river confluences. And then samples were analysed by ICP-MS and -OES to find 41 sediment fingerprints. According to the results of Student's T-distribution mixing model, small creeks in the middle and lower part of the catchment were major source in different size fractions, especially in silt (10-63 μm) samples. Gowrie Creek as covers southern-upstream part of the catchment was a major contributor at the outlet of the catchment in finest size fraction (<10 μm) Large differences between the contributions of suspended sediments from upper tributaries in different size fractions necessitate the selection of appropriate size fraction on sediment tracing in the catchment and also major effect of particle size on the movement and deposition of sediments.
(I Can't Get No) Saturation: A simulation and guidelines for sample sizes in qualitative research.
van Rijnsoever, Frank J
2017-01-01
I explore the sample size in qualitative research that is required to reach theoretical saturation. I conceptualize a population as consisting of sub-populations that contain different types of information sources that hold a number of codes. Theoretical saturation is reached after all the codes in the population have been observed once in the sample. I delineate three different scenarios to sample information sources: "random chance," which is based on probability sampling, "minimal information," which yields at least one new code per sampling step, and "maximum information," which yields the largest number of new codes per sampling step. Next, I use simulations to assess the minimum sample size for each scenario for systematically varying hypothetical populations. I show that theoretical saturation is more dependent on the mean probability of observing codes than on the number of codes in a population. Moreover, the minimal and maximal information scenarios are significantly more efficient than random chance, but yield fewer repetitions per code to validate the findings. I formulate guidelines for purposive sampling and recommend that researchers follow a minimum information scenario.
Feng, Dai; Cortese, Giuliana; Baumgartner, Richard
2017-12-01
The receiver operating characteristic (ROC) curve is frequently used as a measure of accuracy of continuous markers in diagnostic tests. The area under the ROC curve (AUC) is arguably the most widely used summary index for the ROC curve. Although the small sample size scenario is common in medical tests, a comprehensive study of small sample size properties of various methods for the construction of the confidence/credible interval (CI) for the AUC has been by and large missing in the literature. In this paper, we describe and compare 29 non-parametric and parametric methods for the construction of the CI for the AUC when the number of available observations is small. The methods considered include not only those that have been widely adopted, but also those that have been less frequently mentioned or, to our knowledge, never applied to the AUC context. To compare different methods, we carried out a simulation study with data generated from binormal models with equal and unequal variances and from exponential models with various parameters and with equal and unequal small sample sizes. We found that the larger the true AUC value and the smaller the sample size, the larger the discrepancy among the results of different approaches. When the model is correctly specified, the parametric approaches tend to outperform the non-parametric ones. Moreover, in the non-parametric domain, we found that a method based on the Mann-Whitney statistic is in general superior to the others. We further elucidate potential issues and provide possible solutions to along with general guidance on the CI construction for the AUC when the sample size is small. Finally, we illustrate the utility of different methods through real life examples.
Lee, Paul H; Tse, Andy C Y
2017-05-01
There are limited data on the quality of reporting of information essential for replication of the calculation as well as the accuracy of the sample size calculation. We examine the current quality of reporting of the sample size calculation in randomized controlled trials (RCTs) published in PubMed and to examine the variation in reporting across study design, study characteristics, and journal impact factor. We also reviewed the targeted sample size reported in trial registries. We reviewed and analyzed all RCTs published in December 2014 with journals indexed in PubMed. The 2014 Impact Factors for the journals were used as proxies for their quality. Of the 451 analyzed papers, 58.1% reported an a priori sample size calculation. Nearly all papers provided the level of significance (97.7%) and desired power (96.6%), and most of the papers reported the minimum clinically important effect size (73.3%). The median (inter-quartile range) of the percentage difference of the reported and calculated sample size calculation was 0.0% (IQR -4.6%;3.0%). The accuracy of the reported sample size was better for studies published in journals that endorsed the CONSORT statement and journals with an impact factor. A total of 98 papers had provided targeted sample size on trial registries and about two-third of these papers (n=62) reported sample size calculation, but only 25 (40.3%) had no discrepancy with the reported number in the trial registries. The reporting of the sample size calculation in RCTs published in PubMed-indexed journals and trial registries were poor. The CONSORT statement should be more widely endorsed. Copyright © 2016 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.
Analysis of Duplicated Multiple-Samples Rank Data Using the Mack-Skillings Test.
Carabante, Kennet Mariano; Alonso-Marenco, Jose Ramon; Chokumnoyporn, Napapan; Sriwattana, Sujinda; Prinyawiwatkul, Witoon
2016-07-01
Appropriate analysis for duplicated multiple-samples rank data is needed. This study compared analysis of duplicated rank preference data using the Friedman versus Mack-Skillings tests. Panelists (n = 125) ranked twice 2 orange juice sets: different-samples set (100%, 70%, vs. 40% juice) and similar-samples set (100%, 95%, vs. 90%). These 2 sample sets were designed to get contrasting differences in preference. For each sample set, rank sum data were obtained from (1) averaged rank data of each panelist from the 2 replications (n = 125), (2) rank data of all panelists from each of the 2 separate replications (n = 125 each), (3) jointed rank data of all panelists from the 2 replications (n = 125), and (4) rank data of all panelists pooled from the 2 replications (n = 250); rank data (1), (2), and (4) were separately analyzed by the Friedman test, although those from (3) by the Mack-Skillings test. The effect of sample sizes (n = 10 to 125) was evaluated. For the similar-samples set, higher variations in rank data from the 2 replications were observed; therefore, results of the main effects were more inconsistent among methods and sample sizes. Regardless of analysis methods, the larger the sample size, the higher the χ(2) value, the lower the P-value (testing H0 : all samples are not different). Analyzing rank data (2) separately by replication yielded inconsistent conclusions across sample sizes, hence this method is not recommended. The Mack-Skillings test was more sensitive than the Friedman test. Furthermore, it takes into account within-panelist variations and is more appropriate for analyzing duplicated rank data. © 2016 Institute of Food Technologists®
Mass size distribution of particle-bound water
NASA Astrophysics Data System (ADS)
Canepari, S.; Simonetti, G.; Perrino, C.
2017-09-01
The thermal-ramp Karl-Fisher method (tr-KF) for the determination of PM-bound water has been applied to size-segregated PM samples collected in areas subjected to different environmental conditions (protracted atmospheric stability, desert dust intrusion, urban atmosphere). This method, based on the use of a thermal ramp for the desorption of water from PM samples and the subsequent analysis by the coulometric KF technique, had been previously shown to differentiate water contributes retained with different strength and associated to different chemical components in the atmospheric aerosol. The application of the method to size-segregated samples has revealed that water showed a typical mass size distribution in each one of the three environmental situations that were taken into consideration. A very similar size distribution was shown by the chemical PM components that prevailed during each event: ammonium nitrate in the case of atmospheric stability, crustal species in the case of desert dust, road-dust components in the case of urban sites. The shape of the tr-KF curve varied according to the size of the collected particles. Considering the size ranges that better characterize the event (fine fraction for atmospheric stability, coarse fraction for dust intrusion, bi-modal distribution for urban dust), this shape is coherent with the typical tr-KF shape shown by water bound to the chemical species that predominate in the same PM size range (ammonium nitrate, crustal species, secondary/combustion species - road dust components).
Fazey, Francesca M C; Ryan, Peter G
2016-03-01
Recent estimates suggest that roughly 100 times more plastic litter enters the sea than is found floating at the sea surface, despite the buoyancy and durability of many plastic polymers. Biofouling by marine biota is one possible mechanism responsible for this discrepancy. Microplastics (<5 mm in diameter) are more scarce than larger size classes, which makes sense because fouling is a function of surface area whereas buoyancy is a function of volume; the smaller an object, the greater its relative surface area. We tested whether plastic items with high surface area to volume ratios sank more rapidly by submerging 15 different sizes of polyethylene samples in False Bay, South Africa, for 12 weeks to determine the time required for samples to sink. All samples became sufficiently fouled to sink within the study period, but small samples lost buoyancy much faster than larger ones. There was a direct relationship between sample volume (buoyancy) and the time to attain a 50% probability of sinking, which ranged from 17 to 66 days of exposure. Our results provide the first estimates of the longevity of different sizes of plastic debris at the ocean surface. Further research is required to determine how fouling rates differ on free floating debris in different regions and in different types of marine environments. Such estimates could be used to improve model predictions of the distribution and abundance of floating plastic debris globally. Copyright © 2016 Elsevier Ltd. All rights reserved.
Metallographic Characterization of Wrought Depleted Uranium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Forsyth, Robert Thomas; Hill, Mary Ann
Metallographic characterization was performed on wrought depleted uranium (DU) samples taken from the longitudinal and transverse orientations from specific locations on two specimens. Characterization of the samples included general microstructure, inclusion analysis, grain size analysis, and microhardness testing. Comparisons of the characterization results were made to determine any differences based on specimen, sample orientation, or sample location. In addition, the characterization results for the wrought DU samples were also compared with data obtained from the metallographic characterization of cast DU samples previously characterized. No differences were observed in microstructure, inclusion size, morphology, and distribution, or grain size in regard tomore » specimen, location, or orientation for the wrought depleted uranium samples. However, a small difference was observed in average hardness with regard to orientation at the same locations within the same specimen. The longitudinal samples were slightly harder than the transverse samples from the same location of the same specimen. This was true for both wrought DU specimens. Comparing the wrought DU sample data with the previously characterized cast DU sample data, distinct differences in microstructure, inclusion size, morphology and distribution, grain size, and microhardness were observed. As expected, the microstructure of the wrought DU samples consisted of small recrystallized grains which were uniform, randomly oriented, and equiaxed with minimal twinning observed in only a few grains. In contrast, the cast DU microstructure consisted of large irregularly shaped grains with extensive twinning observed in most grains. Inclusions in the wrought DU samples were elongated, broken and cracked and light and dark phases were observed in some inclusions. The mean inclusion area percentage for the wrought DU samples ranged from 0.08% to 0.34% and the average density from all wrought DU samples was 1.62E+04/cm 2. Inclusions in the cast DU samples were equiaxed and intact with light and dark phases observed in some inclusions. The mean inclusion area percentage for the cast DU samples ranged from 0.93% to 1.00% and the average density from all wrought DU samples was 2.83E+04/cm 2. The average mean grain area from all wrought DU samples was 141 μm 2 while the average mean grain area from all cast DU samples was 1.7 mm2. The average Knoop microhardness from all wrought DU samples was 215 HK and the average Knoop microhardness from all cast DU samples was 264 HK.« less
Size and modal analyses of fines and ultrafines from some Apollo 17 samples
NASA Technical Reports Server (NTRS)
Greene, G. M.; King, D. T., Jr.; Banholzer, G. S., Jr.; King, E. A.
1975-01-01
Scanning electron and optical microscopy techniques have been used to determine the grain-size frequency distributions and morphology-based modal analyses of fine and ultrafine fractions of some Apollo 17 regolith samples. There are significant and large differences between the grain-size frequency distributions of the less than 10-micron size fraction of Apollo 17 samples, but there are no clear relations to the local geologic setting from which individual samples have been collected. This may be due to effective lateral mixing of regolith particles in this size range by micrometeoroid impacts. None of the properties of the frequency distributions support the idea of selective transport of any fine grain-size fraction, as has been proposed by other workers. All of the particle types found in the coarser size fractions also occur in the less than 10-micron particles. In the size range from 105 to 10 microns there is a strong tendency for the percentage of regularly shaped glass to increase as the graphic mean grain size of the less than 1-mm size fraction decreases, both probably being controlled by exposure age.
Sample size determination for equivalence assessment with multiple endpoints.
Sun, Anna; Dong, Xiaoyu; Tsong, Yi
2014-01-01
Equivalence assessment between a reference and test treatment is often conducted by two one-sided tests (TOST). The corresponding power function and sample size determination can be derived from a joint distribution of the sample mean and sample variance. When an equivalence trial is designed with multiple endpoints, it often involves several sets of two one-sided tests. A naive approach for sample size determination in this case would select the largest sample size required for each endpoint. However, such a method ignores the correlation among endpoints. With the objective to reject all endpoints and when the endpoints are uncorrelated, the power function is the production of all power functions for individual endpoints. With correlated endpoints, the sample size and power should be adjusted for such a correlation. In this article, we propose the exact power function for the equivalence test with multiple endpoints adjusted for correlation under both crossover and parallel designs. We further discuss the differences in sample size for the naive method without and with correlation adjusted methods and illustrate with an in vivo bioequivalence crossover study with area under the curve (AUC) and maximum concentration (Cmax) as the two endpoints.
Chen, Henian; Zhang, Nanhua; Lu, Xiaosun; Chen, Sophie
2013-08-01
The method used to determine choice of standard deviation (SD) is inadequately reported in clinical trials. Underestimations of the population SD may result in underpowered clinical trials. This study demonstrates how using the wrong method to determine population SD can lead to inaccurate sample sizes and underpowered studies, and offers recommendations to maximize the likelihood of achieving adequate statistical power. We review the practice of reporting sample size and its effect on the power of trials published in major journals. Simulated clinical trials were used to compare the effects of different methods of determining SD on power and sample size calculations. Prior to 1996, sample size calculations were reported in just 1%-42% of clinical trials. This proportion increased from 38% to 54% after the initial Consolidated Standards of Reporting Trials (CONSORT) was published in 1996, and from 64% to 95% after the revised CONSORT was published in 2001. Nevertheless, underpowered clinical trials are still common. Our simulated data showed that all minimal and 25th-percentile SDs fell below 44 (the population SD), regardless of sample size (from 5 to 50). For sample sizes 5 and 50, the minimum sample SDs underestimated the population SD by 90.7% and 29.3%, respectively. If only one sample was available, there was less than 50% chance that the actual power equaled or exceeded the planned power of 80% for detecting a median effect size (Cohen's d = 0.5) when using the sample SD to calculate the sample size. The proportions of studies with actual power of at least 80% were about 95%, 90%, 85%, and 80% when we used the larger SD, 80% upper confidence limit (UCL) of SD, 70% UCL of SD, and 60% UCL of SD to calculate the sample size, respectively. When more than one sample was available, the weighted average SD resulted in about 50% of trials being underpowered; the proportion of trials with power of 80% increased from 90% to 100% when the 75th percentile and the maximum SD from 10 samples were used. Greater sample size is needed to achieve a higher proportion of studies having actual power of 80%. This study only addressed sample size calculation for continuous outcome variables. We recommend using the 60% UCL of SD, maximum SD, 80th-percentile SD, and 75th-percentile SD to calculate sample size when 1 or 2 samples, 3 samples, 4-5 samples, and more than 5 samples of data are available, respectively. Using the sample SD or average SD to calculate sample size should be avoided.
Phase II Trials for Heterogeneous Patient Populations with a Time-to-Event Endpoint.
Jung, Sin-Ho
2017-07-01
In this paper, we consider a single-arm phase II trial with a time-to-event end-point. We assume that the study population has multiple subpopulations with different prognosis, but the study treatment is expected to be similarly efficacious across the subpopulations. We review a stratified one-sample log-rank test and present its sample size calculation method under some practical design settings. Our sample size method requires specification of the prevalence of subpopulations. We observe that the power of the resulting sample size is not very sensitive to misspecification of the prevalence.
Dimensions of design space: a decision-theoretic approach to optimal research design.
Conti, Stefano; Claxton, Karl
2009-01-01
Bayesian decision theory can be used not only to establish the optimal sample size and its allocation in a single clinical study but also to identify an optimal portfolio of research combining different types of study design. Within a single study, the highest societal payoff to proposed research is achieved when its sample sizes and allocation between available treatment options are chosen to maximize the expected net benefit of sampling (ENBS). Where a number of different types of study informing different parameters in the decision problem could be conducted, the simultaneous estimation of ENBS across all dimensions of the design space is required to identify the optimal sample sizes and allocations within such a research portfolio. This is illustrated through a simple example of a decision model of zanamivir for the treatment of influenza. The possible study designs include: 1) a single trial of all the parameters, 2) a clinical trial providing evidence only on clinical endpoints, 3) an epidemiological study of natural history of disease, and 4) a survey of quality of life. The possible combinations, samples sizes, and allocation between trial arms are evaluated over a range of cost-effectiveness thresholds. The computational challenges are addressed by implementing optimization algorithms to search the ENBS surface more efficiently over such large dimensions.
Size effect on atomic structure in low-dimensional Cu-Zr amorphous systems.
Zhang, W B; Liu, J; Lu, S H; Zhang, H; Wang, H; Wang, X D; Cao, Q P; Zhang, D X; Jiang, J Z
2017-08-04
The size effect on atomic structure of a Cu 64 Zr 36 amorphous system, including zero-dimensional small-size amorphous particles (SSAPs) and two-dimensional small-size amorphous films (SSAFs) together with bulk sample was investigated by molecular dynamics simulations. We revealed that sample size strongly affects local atomic structure in both Cu 64 Zr 36 SSAPs and SSAFs, which are composed of core and shell (surface) components. Compared with core component, the shell component of SSAPs has lower average coordination number and average bond length, higher degree of ordering, and lower packing density due to the segregation of Cu atoms on the shell of Cu 64 Zr 36 SSAPs. These atomic structure differences in SSAPs with various sizes result in different glass transition temperatures, in which the glass transition temperature for the shell component is found to be 577 K, which is much lower than 910 K for the core component. We further extended the size effect on the structure and glasses transition temperature to Cu 64 Zr 36 SSAFs, and revealed that the T g decreases when SSAFs becomes thinner due to the following factors: different dynamic motion (mean square displacement), different density of core and surface and Cu segregation on the surface of SSAFs. The obtained results here are different from the results for the size effect on atomic structure of nanometer-sized crystalline metallic alloys.
Liu, Huan; Zhang, Xu; Zhang, Hao; Yao, Xiangwu; Zhou, Meng; Wang, Jiaqi; He, Zhanfei; Zhang, Huihui; Lou, Liping; Mao, Weihua; Zheng, Ping; Hu, Baolan
2018-02-01
In recent years, air pollution events have occurred frequently in China during the winter. Most studies have focused on the physical and chemical composition of polluted air. Some studies have examined the bacterial bioaerosols both indoors and outdoors. But few studies have focused on the relationship between air pollution and bacteria, especially pathogenic bacteria. Airborne PM samples with different diameters and different air quality index values were collected in Hangzhou, China from December 2014 to January 2015. High-throughput sequencing of 16S rRNA was used to categorize the airborne bacteria. Based on the NCBI database, the "Human Pathogen Database" was established, which is related to human health. Among all the PM samples, the diversity and concentration of total bacteria were lowest in the moderately or heavily polluted air. However, in the PM2.5 and PM10 samples, the relative abundances of pathogenic bacteria were highest in the heavily and moderately polluted air respectively. Considering the PM samples with different particle sizes, the diversities of total bacteria and the proportion of pathogenic bacteria in the PM10 samples were different from those in the PM2.5 and TSP samples. The composition of PM samples with different sizes range may be responsible for the variances. The relative humidity, carbon monoxide and ozone concentrations were the main factors, which affected the diversity of total bacteria and the proportion of pathogenic bacteria. Among the different environmental samples, the compositions of the total bacteria were very similar in all the airborne PM samples, but different from those in the water, surface soil, and ground dust samples. Which may be attributed to that the long-distance transport of the airflow may influence the composition of the airborne bacteria. This study of the pathogenic bacteria in airborne PM samples can provide a reference for environmental and public health researchers. Copyright © 2017 Elsevier Ltd. All rights reserved.
Masson, M; Angot, H; Le Bescond, C; Launay, M; Dabrin, A; Miège, C; Le Coz, J; Coquery, M
2018-05-10
Monitoring hydrophobic contaminants in surface freshwaters requires measuring contaminant concentrations in the particulate fraction (sediment or suspended particulate matter, SPM) of the water column. Particle traps (PTs) have been recently developed to sample SPM as cost-efficient, easy to operate and time-integrative tools. But the representativeness of SPM collected with PTs is not fully understood, notably in terms of grain size distribution and particulate organic carbon (POC) content, which could both skew particulate contaminant concentrations. The aim of this study was to evaluate the representativeness of SPM characteristics (i.e. grain size distribution and POC content) and associated contaminants (i.e. polychlorinated biphenyls, PCBs; mercury, Hg) in samples collected in a large river using PTs for differing hydrological conditions. Samples collected using PTs (n = 74) were compared with samples collected during the same time period by continuous flow centrifugation (CFC). The grain size distribution of PT samples shifted with increasing water discharge: the proportion of very fine silts (2-6 μm) decreased while that of coarse silts (27-74 μm) increased. Regardless of water discharge, POC contents were different likely due to integration by PT of high POC-content phytoplankton blooms or low POC-content flood events. Differences in PCBs and Hg concentrations were usually within the range of analytical uncertainties and could not be related to grain size or POC content shifts. Occasional Hg-enriched inputs may have led to higher Hg concentrations in a few PT samples (n = 4) which highlights the time-integrative capacity of the PTs. The differences of annual Hg and PCB fluxes calculated either from PT samples or CFC samples were generally below 20%. Despite some inherent limitations (e.g. grain size distribution bias), our findings suggest that PT sampling is a valuable technique to assess reliable spatial and temporal trends of particulate contaminants such as PCBs and Hg within a river monitoring network. Copyright © 2018 Elsevier B.V. All rights reserved.
Demenais, F; Lathrop, G M; Lalouel, J M
1988-07-01
A simulation study is here conducted to measure the power of the lod score method to detect linkage between a quantitative trait and a marker locus in various situations. The number of families necessary to detect such linkage with 80% power is assessed for different sets of parameters at the trait locus and different values of the recombination fraction. The effects of varying the mode of sampling families and the sibship size are also evaluated.
Demonstration of Multi- and Single-Reader Sample Size Program for Diagnostic Studies software.
Hillis, Stephen L; Schartz, Kevin M
2015-02-01
The recently released software Multi- and Single-Reader Sample Size Sample Size Program for Diagnostic Studies , written by Kevin Schartz and Stephen Hillis, performs sample size computations for diagnostic reader-performance studies. The program computes the sample size needed to detect a specified difference in a reader performance measure between two modalities, when using the analysis methods initially proposed by Dorfman, Berbaum, and Metz (DBM) and Obuchowski and Rockette (OR), and later unified and improved by Hillis and colleagues. A commonly used reader performance measure is the area under the receiver-operating-characteristic curve. The program can be used with typical common reader-performance measures which can be estimated parametrically or nonparametrically. The program has an easy-to-use step-by-step intuitive interface that walks the user through the entry of the needed information. Features of the software include the following: (1) choice of several study designs; (2) choice of inputs obtained from either OR or DBM analyses; (3) choice of three different inference situations: both readers and cases random, readers fixed and cases random, and readers random and cases fixed; (4) choice of two types of hypotheses: equivalence or noninferiority; (6) choice of two output formats: power for specified case and reader sample sizes, or a listing of case-reader combinations that provide a specified power; (7) choice of single or multi-reader analyses; and (8) functionality in Windows, Mac OS, and Linux.
NASA Astrophysics Data System (ADS)
Gnanasaravanan, S.; Rajkumar, P.
2013-05-01
The present study investigates the characterization of minerals in the River Sand (R - Sand) and the Manufactured sand (M-Sand) through FTIR spectroscopic studies. The R - Sand is collected from seven different locations in Cauvery River and M - Sand is collected from eight different manufactures around the Cauvery River belt in Salem, Erode, Tirupur and Namakkal districts of Tamilnadu, India. To extend the effectiveness of the analysis, the samples were subjected to grain size separation to classify the bulk samples into different grain sizes. All the samples were analyzed using FTIR spectrometer. The number of minerals identified with the help of FTIR spectra in overall (bulk) samples of R - Sand is 14 and of M - Sand is 13. The number has been increased while going for grain size separation, i.e., from 14 to 31 for R - Sand and from 13 to 20 for M - Sand. Among all minerals, quartz plays a major role. The relative distribution and the crystallinity nature of quartz have been discussed based on the extinction co-efficient and the crystallinity index values computed. There is no major variation found in M - Sand while going for grain size separation.
The cost of large numbers of hypothesis tests on power, effect size and sample size.
Lazzeroni, L C; Ray, A
2012-01-01
Advances in high-throughput biology and computer science are driving an exponential increase in the number of hypothesis tests in genomics and other scientific disciplines. Studies using current genotyping platforms frequently include a million or more tests. In addition to the monetary cost, this increase imposes a statistical cost owing to the multiple testing corrections needed to avoid large numbers of false-positive results. To safeguard against the resulting loss of power, some have suggested sample sizes on the order of tens of thousands that can be impractical for many diseases or may lower the quality of phenotypic measurements. This study examines the relationship between the number of tests on the one hand and power, detectable effect size or required sample size on the other. We show that once the number of tests is large, power can be maintained at a constant level, with comparatively small increases in the effect size or sample size. For example at the 0.05 significance level, a 13% increase in sample size is needed to maintain 80% power for ten million tests compared with one million tests, whereas a 70% increase in sample size is needed for 10 tests compared with a single test. Relative costs are less when measured by increases in the detectable effect size. We provide an interactive Excel calculator to compute power, effect size or sample size when comparing study designs or genome platforms involving different numbers of hypothesis tests. The results are reassuring in an era of extreme multiple testing.
NASA Astrophysics Data System (ADS)
Dietze, Michael; Fuchs, Margret; Kreutzer, Sebastian
2016-04-01
Many modern approaches of radiometric dating or geochemical fingerprinting rely on sampling sedimentary deposits. A key assumption of most concepts is that the extracted grain-size fraction of the sampled sediment adequately represents the actual process to be dated or the source area to be fingerprinted. However, these assumptions are not always well constrained. Rather, they have to align with arbitrary, method-determined size intervals, such as "coarse grain" or "fine grain" with partly even different definitions. Such arbitrary intervals violate principal process-based concepts of sediment transport and can thus introduce significant bias to the analysis outcome (i.e., a deviation of the measured from the true value). We present a flexible numerical framework (numOlum) for the statistical programming language R that allows quantifying the bias due to any given analysis size interval for different types of sediment deposits. This framework is applied to synthetic samples from the realms of luminescence dating and geochemical fingerprinting, i.e. a virtual reworked loess section. We show independent validation data from artificially dosed and subsequently mixed grain-size proportions and we present a statistical approach (end-member modelling analysis, EMMA) that allows accounting for the effect of measuring the compound dosimetric history or geochemical composition of a sample. EMMA separates polymodal grain-size distributions into the underlying transport process-related distributions and their contribution to each sample. These underlying distributions can then be used to adjust grain-size preparation intervals to minimise the incorporation of "undesired" grain-size fractions.
Perez, Aurora; Hernández, Rebeca; Velasco, Diego; Voicu, Dan; Mijangos, Carmen
2015-03-01
Microfluidic techniques are expected to provide narrower particle size distribution than conventional methods for the preparation of poly (lactic-co-glycolic acid) (PLGA) microparticles. Besides, it is hypothesized that the particle size distribution of poly (lactic-co-glycolic acid) microparticles influences the settling behavior and rheological properties of its aqueous dispersions. For the preparation of PLGA particles, two different methods, microfluidic and conventional oil-in-water emulsification methods were employed. The particle size and particle size distribution of PLGA particles prepared by microfluidics were studied as a function of the flow rate of the organic phase while particles prepared by conventional methods were studied as a function of stirring rate. In order to study the stability and structural organization of colloidal dispersions, settling experiments and oscillatory rheological measurements were carried out on aqueous dispersions of PLGA particles with different particle size distributions. Microfluidics technique allowed the control of size and size distribution of the droplets formed in the process of emulsification. This resulted in a narrower particle size distribution for samples prepared by MF with respect to samples prepared by conventional methods. Polydisperse samples showed a larger tendency to aggregate, thus confirming the advantages of microfluidics over conventional methods, especially if biomedical applications are envisaged. Copyright © 2014 Elsevier Inc. All rights reserved.
Effect of roll hot press temperature on crystallite size of PVDF film
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hartono, Ambran, E-mail: ambranhartono@yahoo.com; Sanjaya, Edi; Djamal, Mitra
2014-03-24
Fabrication PVDF films have been made using Hot Roll Press. Preparation of samples carried out for nine different temperatures. This condition is carried out to see the effect of Roll Hot Press temperature on the size of the crystallite of PVDF films. To obtain the diffraction pattern of sample characterization is performed using X-Ray Diffraction. Furthermore, from the diffraction pattern is obtained, the calculation to determine the crystallite size of the sample by using the Scherrer equation. From the experimental results and the calculation of crystallite sizes obtained for the samples with temperature 130 °C up to 170 °C respectivelymore » increased from 7.2 nm up to 20.54 nm. These results show that increasing temperatures will also increase the size of the crystallite of the sample. This happens because with the increasing temperature causes the higher the degree of crystallization of PVDF film sample is formed, so that the crystallite size also increases. This condition indicates that the specific volume or size of the crystals depends on the magnitude of the temperature as it has been studied by Nakagawa.« less
Designing a two-rank acceptance sampling plan for quality inspection of geospatial data products
NASA Astrophysics Data System (ADS)
Tong, Xiaohua; Wang, Zhenhua; Xie, Huan; Liang, Dan; Jiang, Zuoqin; Li, Jinchao; Li, Jun
2011-10-01
To address the disadvantages of classical sampling plans designed for traditional industrial products, we originally propose a two-rank acceptance sampling plan (TRASP) for the inspection of geospatial data outputs based on the acceptance quality level (AQL). The first rank sampling plan is to inspect the lot consisting of map sheets, and the second is to inspect the lot consisting of features in an individual map sheet. The TRASP design is formulated as an optimization problem with respect to sample size and acceptance number, which covers two lot size cases. The first case is for a small lot size with nonconformities being modeled by a hypergeometric distribution function, and the second is for a larger lot size with nonconformities being modeled by a Poisson distribution function. The proposed TRASP is illustrated through two empirical case studies. Our analysis demonstrates that: (1) the proposed TRASP provides a general approach for quality inspection of geospatial data outputs consisting of non-uniform items and (2) the proposed acceptance sampling plan based on TRASP performs better than other classical sampling plans. It overcomes the drawbacks of percent sampling, i.e., "strictness for large lot size, toleration for small lot size," and those of a national standard used specifically for industrial outputs, i.e., "lots with different sizes corresponding to the same sampling plan."
HYPERSAMP - HYPERGEOMETRIC ATTRIBUTE SAMPLING SYSTEM BASED ON RISK AND FRACTION DEFECTIVE
NASA Technical Reports Server (NTRS)
De, Salvo L. J.
1994-01-01
HYPERSAMP is a demonstration of an attribute sampling system developed to determine the minimum sample size required for any preselected value for consumer's risk and fraction of nonconforming. This statistical method can be used in place of MIL-STD-105E sampling plans when a minimum sample size is desirable, such as when tests are destructive or expensive. HYPERSAMP utilizes the Hypergeometric Distribution and can be used for any fraction nonconforming. The program employs an iterative technique that circumvents the obstacle presented by the factorial of a non-whole number. HYPERSAMP provides the required Hypergeometric sample size for any equivalent real number of nonconformances in the lot or batch under evaluation. Many currently used sampling systems, such as the MIL-STD-105E, utilize the Binomial or the Poisson equations as an estimate of the Hypergeometric when performing inspection by attributes. However, this is primarily because of the difficulty in calculation of the factorials required by the Hypergeometric. Sampling plans based on the Binomial or Poisson equations will result in the maximum sample size possible with the Hypergeometric. The difference in the sample sizes between the Poisson or Binomial and the Hypergeometric can be significant. For example, a lot size of 400 devices with an error rate of 1.0% and a confidence of 99% would require a sample size of 400 (all units would need to be inspected) for the Binomial sampling plan and only 273 for a Hypergeometric sampling plan. The Hypergeometric results in a savings of 127 units, a significant reduction in the required sample size. HYPERSAMP is a demonstration program and is limited to sampling plans with zero defectives in the sample (acceptance number of zero). Since it is only a demonstration program, the sample size determination is limited to sample sizes of 1500 or less. The Hypergeometric Attribute Sampling System demonstration code is a spreadsheet program written for IBM PC compatible computers running DOS and Lotus 1-2-3 or Quattro Pro. This program is distributed on a 5.25 inch 360K MS-DOS format diskette, and the program price includes documentation. This statistical method was developed in 1992.
Development of a Multiple-Stage Differential Mobility Analyzer (MDMA)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Da-Ren; Cheng, Mengdawn
2007-01-01
A new DMA column has been designed with the capability of simultaneously extracting monodisperse particles of different sizes in multiple stages. We call this design a multistage DMA, or MDMA. A prototype MDMA has been constructed and experimentally evaluated in this study. The new column enables the fast measurement of particles in a wide size range, while preserving the powerful particle classification function of a DMA. The prototype MDMA has three sampling stages, capable of classifying monodisperse particles of three different sizes simultaneously. The scanning voltage operation of a DMA can be applied to this new column. Each stage ofmore » MDMA column covers a fraction of the entire particle size range to be measured. The covered size fractions of two adjacent stages of the MDMA are designed somewhat overlapped. The arrangement leads to the reduction of scanning voltage range and thus the cycling time of the measurement. The modular sampling stage design of the MDMA allows the flexible configuration of desired particle classification lengths and variable number of stages in the MDMA. The design of our MDMA also permits operation at high sheath flow, enabling high-resolution particle size measurement and/or reduction of the lower sizing limit. Using the tandem DMA technique, the performance of the MDMA, i.e., sizing accuracy, resolution, and transmission efficiency, was evaluated at different ratios of aerosol and sheath flowrates. Two aerosol sampling schemes were investigated. One was to extract aerosol flows at an evenly partitioned flowrate at each stage, and the other was to extract aerosol at a rate the same as the polydisperse aerosol flowrate at each stage. We detail the prototype design of the MDMA and the evaluation result on the transfer functions of the MDMA at different particle sizes and operational conditions.« less
A Bayesian sequential design using alpha spending function to control type I error.
Zhu, Han; Yu, Qingzhao
2017-10-01
We propose in this article a Bayesian sequential design using alpha spending functions to control the overall type I error in phase III clinical trials. We provide algorithms to calculate critical values, power, and sample sizes for the proposed design. Sensitivity analysis is implemented to check the effects from different prior distributions, and conservative priors are recommended. We compare the power and actual sample sizes of the proposed Bayesian sequential design with different alpha spending functions through simulations. We also compare the power of the proposed method with frequentist sequential design using the same alpha spending function. Simulations show that, at the same sample size, the proposed method provides larger power than the corresponding frequentist sequential design. It also has larger power than traditional Bayesian sequential design which sets equal critical values for all interim analyses. When compared with other alpha spending functions, O'Brien-Fleming alpha spending function has the largest power and is the most conservative in terms that at the same sample size, the null hypothesis is the least likely to be rejected at early stage of clinical trials. And finally, we show that adding a step of stop for futility in the Bayesian sequential design can reduce the overall type I error and reduce the actual sample sizes.
Wu, Zhichao; Medeiros, Felipe A
2018-03-20
Visual field testing is an important endpoint in glaucoma clinical trials, and the testing paradigm used can have a significant impact on the sample size requirements. To investigate this, this study included 353 eyes of 247 glaucoma patients seen over a 3-year period to extract real-world visual field rates of change and variability estimates to provide sample size estimates from computer simulations. The clinical trial scenario assumed that a new treatment was added to one of two groups that were both under routine clinical care, with various treatment effects examined. Three different visual field testing paradigms were evaluated: a) evenly spaced testing, b) United Kingdom Glaucoma Treatment Study (UKGTS) follow-up scheme, which adds clustered tests at the beginning and end of follow-up in addition to evenly spaced testing, and c) clustered testing paradigm, with clusters of tests at the beginning and end of the trial period and two intermediary visits. The sample size requirements were reduced by 17-19% and 39-40% using the UKGTS and clustered testing paradigms, respectively, when compared to the evenly spaced approach. These findings highlight how the clustered testing paradigm can substantially reduce sample size requirements and improve the feasibility of future glaucoma clinical trials.
Pohlert, Thorsten; Hillebrand, Gudrun; Breitung, Vera
2011-06-01
This study focusses on the effect of sampling techniques for suspended matter in stream water on subsequent particle-size distribution and concentrations of total organic carbon and selected persistent organic pollutants. The key questions are whether differences between the sampling techniques are due to the separation principle of the devices or due to the difference between time-proportional versus integral sampling. Several multivariate homogeneity tests were conducted on an extensive set of field-data that covers the period from 2002 to 2007, when up to three different sampling techniques were deployed in parallel at four monitoring stations of the River Rhine. The results indicate homogeneity for polychlorinated biphenyls, but significant effects due to the sampling techniques on particle-size, organic carbon and hexachlorobenzene. The effects can be amplified depending on the site characteristics of the monitoring stations.
Smith, Philip L; Lilburn, Simon D; Corbett, Elaine A; Sewell, David K; Kyllingsbæk, Søren
2016-09-01
We investigated the capacity of visual short-term memory (VSTM) in a phase discrimination task that required judgments about the configural relations between pairs of black and white features. Sewell et al. (2014) previously showed that VSTM capacity in an orientation discrimination task was well described by a sample-size model, which views VSTM as a resource comprised of a finite number of noisy stimulus samples. The model predicts the invariance of [Formula: see text] , the sum of squared sensitivities across items, for displays of different sizes. For phase discrimination, the set-size effect significantly exceeded that predicted by the sample-size model for both simultaneously and sequentially presented stimuli. Instead, the set-size effect and the serial position curves with sequential presentation were predicted by an attention-weighted version of the sample-size model, which assumes that one of the items in the display captures attention and receives a disproportionate share of resources. The choice probabilities and response time distributions from the task were well described by a diffusion decision model in which the drift rates embodied the assumptions of the attention-weighted sample-size model. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Geometrical characteristics of sandstone with different sample sizes
NASA Astrophysics Data System (ADS)
Cheon, D. S.; Takahashi, M., , Dr
2017-12-01
In many rock engineering projects such as CO2 underground storage, engineering geothermal system, it is important things to understand the fluid flow behavior in the deep geological conditions. This fluid flow is generally affected by the geometrical characteristics of rock, especially porous media. Furthermore, physical properties in rock may depend on the existence of voids space in rock. Total porosity and pore size distribution can be measured by Mercury Intrusion Porosimetry and the other geometrical and spatial information of pores can be obtained through micro-focus X-ray CT. Using the micro-focus X-ray CT, we obtained the extracted void space and transparent image from the original CT voxel images of with different sample sizes like 1 mm, 2 mm, 3 mm cubes. The test samples are Berea sandstone and Otway sandstone. The former is well-known sandstone and it is used for the standard sample to compared to the result from the Otway sandstone. Otway sandstone was obtained from the CO2CRC Otway pilot site for the CO2 geosequestraion project. From the X-ray scan and ExFACT software, we get the informations including effective pore radii, coordination number, tortuosity and effective throat/pore radius ratio etc. The geometrical information analysis showed that for Berea sandstone and Otway sandstone, there is rarely differences with different sample sizes and total value of coordination number show high porosity, the tortuosity of Berea sandstone is higher than the Otway sandstone. In the future, these information will be used for the permeability of the samples.
An audit of the statistics and the comparison with the parameter in the population
NASA Astrophysics Data System (ADS)
Bujang, Mohamad Adam; Sa'at, Nadiah; Joys, A. Reena; Ali, Mariana Mohamad
2015-10-01
The sufficient sample size that is needed to closely estimate the statistics for particular parameters are use to be an issue. Although sample size might had been calculated referring to objective of the study, however, it is difficult to confirm whether the statistics are closed with the parameter for a particular population. All these while, guideline that uses a p-value less than 0.05 is widely used as inferential evidence. Therefore, this study had audited results that were analyzed from various sub sample and statistical analyses and had compared the results with the parameters in three different populations. Eight types of statistical analysis and eight sub samples for each statistical analysis were analyzed. Results found that the statistics were consistent and were closed to the parameters when the sample study covered at least 15% to 35% of population. Larger sample size is needed to estimate parameter that involve with categorical variables compared with numerical variables. Sample sizes with 300 to 500 are sufficient to estimate the parameters for medium size of population.
Sample allocation balancing overall representativeness and stratum precision.
Diaz-Quijano, Fredi Alexander
2018-05-07
In large-scale surveys, it is often necessary to distribute a preset sample size among a number of strata. Researchers must make a decision between prioritizing overall representativeness or precision of stratum estimates. Hence, I evaluated different sample allocation strategies based on stratum size. The strategies evaluated herein included allocation proportional to stratum population; equal sample for all strata; and proportional to the natural logarithm, cubic root, and square root of the stratum population. This study considered the fact that, from a preset sample size, the dispersion index of stratum sampling fractions is correlated with the population estimator error and the dispersion index of stratum-specific sampling errors would measure the inequality in precision distribution. Identification of a balanced and efficient strategy was based on comparing those both dispersion indices. Balance and efficiency of the strategies changed depending on overall sample size. As the sample to be distributed increased, the most efficient allocation strategies were equal sample for each stratum; proportional to the logarithm, to the cubic root, to square root; and that proportional to the stratum population, respectively. Depending on sample size, each of the strategies evaluated could be considered in optimizing the sample to keep both overall representativeness and stratum-specific precision. Copyright © 2018 Elsevier Inc. All rights reserved.
Comparison of Sample Size by Bootstrap and by Formulas Based on Normal Distribution Assumption.
Wang, Zuozhen
2018-01-01
Bootstrapping technique is distribution-independent, which provides an indirect way to estimate the sample size for a clinical trial based on a relatively smaller sample. In this paper, sample size estimation to compare two parallel-design arms for continuous data by bootstrap procedure are presented for various test types (inequality, non-inferiority, superiority, and equivalence), respectively. Meanwhile, sample size calculation by mathematical formulas (normal distribution assumption) for the identical data are also carried out. Consequently, power difference between the two calculation methods is acceptably small for all the test types. It shows that the bootstrap procedure is a credible technique for sample size estimation. After that, we compared the powers determined using the two methods based on data that violate the normal distribution assumption. To accommodate the feature of the data, the nonparametric statistical method of Wilcoxon test was applied to compare the two groups in the data during the process of bootstrap power estimation. As a result, the power estimated by normal distribution-based formula is far larger than that by bootstrap for each specific sample size per group. Hence, for this type of data, it is preferable that the bootstrap method be applied for sample size calculation at the beginning, and that the same statistical method as used in the subsequent statistical analysis is employed for each bootstrap sample during the course of bootstrap sample size estimation, provided there is historical true data available that can be well representative of the population to which the proposed trial is planning to extrapolate.
(I Can’t Get No) Saturation: A simulation and guidelines for sample sizes in qualitative research
2017-01-01
I explore the sample size in qualitative research that is required to reach theoretical saturation. I conceptualize a population as consisting of sub-populations that contain different types of information sources that hold a number of codes. Theoretical saturation is reached after all the codes in the population have been observed once in the sample. I delineate three different scenarios to sample information sources: “random chance,” which is based on probability sampling, “minimal information,” which yields at least one new code per sampling step, and “maximum information,” which yields the largest number of new codes per sampling step. Next, I use simulations to assess the minimum sample size for each scenario for systematically varying hypothetical populations. I show that theoretical saturation is more dependent on the mean probability of observing codes than on the number of codes in a population. Moreover, the minimal and maximal information scenarios are significantly more efficient than random chance, but yield fewer repetitions per code to validate the findings. I formulate guidelines for purposive sampling and recommend that researchers follow a minimum information scenario. PMID:28746358
NASA Astrophysics Data System (ADS)
Alexander, Louise; Snape, Joshua F.; Joy, Katherine H.; Downes, Hilary; Crawford, Ian A.
2016-09-01
Lunar mare basalts provide insights into the compositional diversity of the Moon's interior. Basalt fragments from the lunar regolith can potentially sample lava flows from regions of the Moon not previously visited, thus, increasing our understanding of lunar geological evolution. As part of a study of basaltic diversity at the Apollo 12 landing site, detailed petrological and geochemical data are provided here for 13 basaltic chips. In addition to bulk chemistry, we have analyzed the major, minor, and trace element chemistry of mineral phases which highlight differences between basalt groups. Where samples contain olivine, the equilibrium parent melt magnesium number (Mg#; atomic Mg/[Mg + Fe]) can be calculated to estimate parent melt composition. Ilmenite and plagioclase chemistry can also determine differences between basalt groups. We conclude that samples of approximately 1-2 mm in size can be categorized provided that appropriate mineral phases (olivine, plagioclase, and ilmenite) are present. Where samples are fine-grained (grain size <0.3 mm), a "paired samples t-test" can provide a statistical comparison between a particular sample and known lunar basalts. Of the fragments analyzed here, three are found to belong to each of the previously identified olivine and ilmenite basalt suites, four to the pigeonite basalt suite, one is an olivine cumulate, and two could not be categorized because of their coarse grain sizes and lack of appropriate mineral phases. Our approach introduces methods that can be used to investigate small sample sizes (i.e., fines) from future sample return missions to investigate lava flow diversity and petrological significance.
Designing image segmentation studies: Statistical power, sample size and reference standard quality.
Gibson, Eli; Hu, Yipeng; Huisman, Henkjan J; Barratt, Dean C
2017-12-01
Segmentation algorithms are typically evaluated by comparison to an accepted reference standard. The cost of generating accurate reference standards for medical image segmentation can be substantial. Since the study cost and the likelihood of detecting a clinically meaningful difference in accuracy both depend on the size and on the quality of the study reference standard, balancing these trade-offs supports the efficient use of research resources. In this work, we derive a statistical power calculation that enables researchers to estimate the appropriate sample size to detect clinically meaningful differences in segmentation accuracy (i.e. the proportion of voxels matching the reference standard) between two algorithms. Furthermore, we derive a formula to relate reference standard errors to their effect on the sample sizes of studies using lower-quality (but potentially more affordable and practically available) reference standards. The accuracy of the derived sample size formula was estimated through Monte Carlo simulation, demonstrating, with 95% confidence, a predicted statistical power within 4% of simulated values across a range of model parameters. This corresponds to sample size errors of less than 4 subjects and errors in the detectable accuracy difference less than 0.6%. The applicability of the formula to real-world data was assessed using bootstrap resampling simulations for pairs of algorithms from the PROMISE12 prostate MR segmentation challenge data set. The model predicted the simulated power for the majority of algorithm pairs within 4% for simulated experiments using a high-quality reference standard and within 6% for simulated experiments using a low-quality reference standard. A case study, also based on the PROMISE12 data, illustrates using the formulae to evaluate whether to use a lower-quality reference standard in a prostate segmentation study. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Zhu, Hong; Xu, Xiaohan; Ahn, Chul
2017-01-01
Paired experimental design is widely used in clinical and health behavioral studies, where each study unit contributes a pair of observations. Investigators often encounter incomplete observations of paired outcomes in the data collected. Some study units contribute complete pairs of observations, while the others contribute either pre- or post-intervention observations. Statistical inference for paired experimental design with incomplete observations of continuous outcomes has been extensively studied in literature. However, sample size method for such study design is sparsely available. We derive a closed-form sample size formula based on the generalized estimating equation approach by treating the incomplete observations as missing data in a linear model. The proposed method properly accounts for the impact of mixed structure of observed data: a combination of paired and unpaired outcomes. The sample size formula is flexible to accommodate different missing patterns, magnitude of missingness, and correlation parameter values. We demonstrate that under complete observations, the proposed generalized estimating equation sample size estimate is the same as that based on the paired t-test. In the presence of missing data, the proposed method would lead to a more accurate sample size estimate comparing with the crude adjustment. Simulation studies are conducted to evaluate the finite-sample performance of the generalized estimating equation sample size formula. A real application example is presented for illustration.
Lachin, John M.; McGee, Paula L.; Greenbaum, Carla J.; Palmer, Jerry; Gottlieb, Peter; Skyler, Jay
2011-01-01
Preservation of -cell function as measured by stimulated C-peptide has recently been accepted as a therapeutic target for subjects with newly diagnosed type 1 diabetes. In recently completed studies conducted by the Type 1 Diabetes Trial Network (TrialNet), repeated 2-hour Mixed Meal Tolerance Tests (MMTT) were obtained for up to 24 months from 156 subjects with up to 3 months duration of type 1 diabetes at the time of study enrollment. These data provide the information needed to more accurately determine the sample size needed for future studies of the effects of new agents on the 2-hour area under the curve (AUC) of the C-peptide values. The natural log(), log(+1) and square-root transformations of the AUC were assessed. In general, a transformation of the data is needed to better satisfy the normality assumptions for commonly used statistical tests. Statistical analysis of the raw and transformed data are provided to estimate the mean levels over time and the residual variation in untreated subjects that allow sample size calculations for future studies at either 12 or 24 months of follow-up and among children 8–12 years of age, adolescents (13–17 years) and adults (18+ years). The sample size needed to detect a given relative (percentage) difference with treatment versus control is greater at 24 months than at 12 months of follow-up, and differs among age categories. Owing to greater residual variation among those 13–17 years of age, a larger sample size is required for this age group. Methods are also described for assessment of sample size for mixtures of subjects among the age categories. Statistical expressions are presented for the presentation of analyses of log(+1) and transformed values in terms of the original units of measurement (pmol/ml). Analyses using different transformations are described for the TrialNet study of masked anti-CD20 (rituximab) versus masked placebo. These results provide the information needed to accurately evaluate the sample size for studies of new agents to preserve C-peptide levels in newly diagnosed type 1 diabetes. PMID:22102862
Lachin, John M; McGee, Paula L; Greenbaum, Carla J; Palmer, Jerry; Pescovitz, Mark D; Gottlieb, Peter; Skyler, Jay
2011-01-01
Preservation of β-cell function as measured by stimulated C-peptide has recently been accepted as a therapeutic target for subjects with newly diagnosed type 1 diabetes. In recently completed studies conducted by the Type 1 Diabetes Trial Network (TrialNet), repeated 2-hour Mixed Meal Tolerance Tests (MMTT) were obtained for up to 24 months from 156 subjects with up to 3 months duration of type 1 diabetes at the time of study enrollment. These data provide the information needed to more accurately determine the sample size needed for future studies of the effects of new agents on the 2-hour area under the curve (AUC) of the C-peptide values. The natural log(x), log(x+1) and square-root (√x) transformations of the AUC were assessed. In general, a transformation of the data is needed to better satisfy the normality assumptions for commonly used statistical tests. Statistical analysis of the raw and transformed data are provided to estimate the mean levels over time and the residual variation in untreated subjects that allow sample size calculations for future studies at either 12 or 24 months of follow-up and among children 8-12 years of age, adolescents (13-17 years) and adults (18+ years). The sample size needed to detect a given relative (percentage) difference with treatment versus control is greater at 24 months than at 12 months of follow-up, and differs among age categories. Owing to greater residual variation among those 13-17 years of age, a larger sample size is required for this age group. Methods are also described for assessment of sample size for mixtures of subjects among the age categories. Statistical expressions are presented for the presentation of analyses of log(x+1) and √x transformed values in terms of the original units of measurement (pmol/ml). Analyses using different transformations are described for the TrialNet study of masked anti-CD20 (rituximab) versus masked placebo. These results provide the information needed to accurately evaluate the sample size for studies of new agents to preserve C-peptide levels in newly diagnosed type 1 diabetes.
Stable water isotopologue ratios in fog and cloud droplets of liquid clouds are not size-dependent
Spiegel, J.K.; Aemisegger, F.; Scholl, M.; Wienhold, F.G.; Collett, J.L.; Lee, T.; van Pinxteren, D.; Mertes, S.; Tilgner, A.; Herrmann, H.; Werner, Roland A.; Buchmann, N.; Eugster, W.
2012-01-01
In this work, we present the first observations of stable water isotopologue ratios in cloud droplets of different sizes collected simultaneously. We address the question whether the isotope ratio of droplets in a liquid cloud varies as a function of droplet size. Samples were collected from a ground intercepted cloud (= fog) during the Hill Cap Cloud Thuringia 2010 campaign (HCCT-2010) using a three-stage Caltech Active Strand Cloud water Collector (CASCC). An instrument test revealed that no artificial isotopic fractionation occurs during sample collection with the CASCC. Furthermore, we could experimentally confirm the hypothesis that the δ values of cloud droplets of the relevant droplet sizes (μm-range) were not significantly different and thus can be assumed to be in isotopic equilibrium immediately with the surrounding water vapor. However, during the dissolution period of the cloud, when the supersaturation inside the cloud decreased and the cloud began to clear, differences in isotope ratios of the different droplet sizes tended to be larger. This is likely to result from the cloud's heterogeneity, implying that larger and smaller cloud droplets have been collected at different moments in time, delivering isotope ratios from different collection times.
Arnup, Sarah J; McKenzie, Joanne E; Pilcher, David; Bellomo, Rinaldo; Forbes, Andrew B
2018-06-01
The cluster randomised crossover (CRXO) design provides an opportunity to conduct randomised controlled trials to evaluate low risk interventions in the intensive care setting. Our aim is to provide a tutorial on how to perform a sample size calculation for a CRXO trial, focusing on the meaning of the elements required for the calculations, with application to intensive care trials. We use all-cause in-hospital mortality from the Australian and New Zealand Intensive Care Society Adult Patient Database clinical registry to illustrate the sample size calculations. We show sample size calculations for a two-intervention, two 12-month period, cross-sectional CRXO trial. We provide the formulae, and examples of their use, to determine the number of intensive care units required to detect a risk ratio (RR) with a designated level of power between two interventions for trials in which the elements required for sample size calculations remain constant across all ICUs (unstratified design); and in which there are distinct groups (strata) of ICUs that differ importantly in the elements required for sample size calculations (stratified design). The CRXO design markedly reduces the sample size requirement compared with the parallel-group, cluster randomised design for the example cases. The stratified design further reduces the sample size requirement compared with the unstratified design. The CRXO design enables the evaluation of routinely used interventions that can bring about small, but important, improvements in patient care in the intensive care setting.
Rosenberger, Amanda E.; Dunham, Jason B.
2005-01-01
Estimation of fish abundance in streams using the removal model or the Lincoln - Peterson mark - recapture model is a common practice in fisheries. These models produce misleading results if their assumptions are violated. We evaluated the assumptions of these two models via electrofishing of rainbow trout Oncorhynchus mykiss in central Idaho streams. For one-, two-, three-, and four-pass sampling effort in closed sites, we evaluated the influences of fish size and habitat characteristics on sampling efficiency and the accuracy of removal abundance estimates. We also examined the use of models to generate unbiased estimates of fish abundance through adjustment of total catch or biased removal estimates. Our results suggested that the assumptions of the mark - recapture model were satisfied and that abundance estimates based on this approach were unbiased. In contrast, the removal model assumptions were not met. Decreasing sampling efficiencies over removal passes resulted in underestimated population sizes and overestimates of sampling efficiency. This bias decreased, but was not eliminated, with increased sampling effort. Biased removal estimates based on different levels of effort were highly correlated with each other but were less correlated with unbiased mark - recapture estimates. Stream size decreased sampling efficiency, and stream size and instream wood increased the negative bias of removal estimates. We found that reliable estimates of population abundance could be obtained from models of sampling efficiency for different levels of effort. Validation of abundance estimates requires extra attention to routine sampling considerations but can help fisheries biologists avoid pitfalls associated with biased data and facilitate standardized comparisons among studies that employ different sampling methods.
EPR investigation of UV light effect on calcium carbonate powders with different grain sizes.
Kabacińska, Zuzanna; Krzyminiewski, Ryszard; Dobosz, Bernadeta
2014-06-01
This study is based on investigation of calcium carbonate powders with different grain sizes exposed to UV light. Calcium carbonate is widely used in many branches of industry, e.g. as a filler for polymer materials; therefore, knowing its properties, among them also its reaction to UV light, is essential. Samples of powdered calcium carbonate with average grain sizes of 69 and 300 nm and 2.1, 6, 16, 25 µm were used in this investigation. Measurements were performed at room temperature using EPR X-band spectrometer, and they have shown the additional signals induced by the light from Hg lamp. The effect of annealing of the micro-grain samples was also studied. The spectra of four micro-grain samples after irradiation are similar, but there are differences between them and the other two powders, which could be related to the different sizes of their grains. Further studies based on these preliminary results may prove useful in research of photodegradation of CaCO3-filled materials, as well as helpful in increasing the accuracy of dating of archaeological and geological objects. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Johnston, Lisa G; McLaughlin, Katherine R; Rhilani, Houssine El; Latifi, Amina; Toufik, Abdalla; Bennani, Aziza; Alami, Kamal; Elomari, Boutaina; Handcock, Mark S
2015-01-01
Background Respondent-driven sampling is used worldwide to estimate the population prevalence of characteristics such as HIV/AIDS and associated risk factors in hard-to-reach populations. Estimating the total size of these populations is of great interest to national and international organizations, however reliable measures of population size often do not exist. Methods Successive Sampling-Population Size Estimation (SS-PSE) along with network size imputation allows population size estimates to be made without relying on separate studies or additional data (as in network scale-up, multiplier and capture-recapture methods), which may be biased. Results Ten population size estimates were calculated for people who inject drugs, female sex workers, men who have sex with other men, and migrants from sub-Sahara Africa in six different cities in Morocco. SS-PSE estimates fell within or very close to the likely values provided by experts and the estimates from previous studies using other methods. Conclusions SS-PSE is an effective method for estimating the size of hard-to-reach populations that leverages important information within respondent-driven sampling studies. The addition of a network size imputation method helps to smooth network sizes allowing for more accurate results. However, caution should be used particularly when there is reason to believe that clustered subgroups may exist within the population of interest or when the sample size is small in relation to the population. PMID:26258908
Consideration of Kaolinite Interference Correction for Quartz Measurements in Coal Mine Dust
Lee, Taekhee; Chisholm, William P.; Kashon, Michael; Key-Schwartz, Rosa J.; Harper, Martin
2015-01-01
Kaolinite interferes with the infrared analysis of quartz. Improper correction can cause over- or underestimation of silica concentration. The standard sampling method for quartz in coal mine dust is size selective, and, since infrared spectrometry is sensitive to particle size, it is intuitively better to use the same size fractions for quantification of quartz and kaolinite. Standard infrared spectrometric methods for quartz measurement in coal mine dust correct interference from the kaolinite, but they do not specify a particle size for the material used for correction. This study compares calibration curves using as-received and respirable size fractions of nine different examples of kaolinite in the different correction methods from the National Institute for Occupational Safety and Health Manual of Analytical Methods (NMAM) 7603 and the Mine Safety and Health Administration (MSHA) P-7. Four kaolinites showed significant differences between calibration curves with as-received and respirable size fractions for NMAM 7603 and seven for MSHA P-7. The quartz mass measured in 48 samples spiked with respirable fraction silica and kaolinite ranged between 0.28 and 23% (NMAM 7603) and 0.18 and 26% (MSHA P-7) of the expected applied mass when the kaolinite interference was corrected with respirable size fraction kaolinite. This is termed “deviation,” not bias, because the applied mass is also subject to unknown variance. Generally, the deviations in the spiked samples are larger when corrected with the as-received size fraction of kaolinite than with the respirable size fraction. Results indicate that if a kaolinite correction with reference material of respirable size fraction is applied in current standard methods for quartz measurement in coal mine dust, the quartz result would be somewhat closer to the true exposure, although the actual mass difference would be small. Most kinds of kaolinite can be used for laboratory calibration, but preferably, the size fraction should be the same as the coal dust being collected. PMID:23767881
Consideration of kaolinite interference correction for quartz measurements in coal mine dust.
Lee, Taekhee; Chisholm, William P; Kashon, Michael; Key-Schwartz, Rosa J; Harper, Martin
2013-01-01
Kaolinite interferes with the infrared analysis of quartz. Improper correction can cause over- or underestimation of silica concentration. The standard sampling method for quartz in coal mine dust is size selective, and, since infrared spectrometry is sensitive to particle size, it is intuitively better to use the same size fractions for quantification of quartz and kaolinite. Standard infrared spectrometric methods for quartz measurement in coal mine dust correct interference from the kaolinite, but they do not specify a particle size for the material used for correction. This study compares calibration curves using as-received and respirable size fractions of nine different examples of kaolinite in the different correction methods from the National Institute for Occupational Safety and Health Manual of Analytical Methods (NMAM) 7603 and the Mine Safety and Health Administration (MSHA) P-7. Four kaolinites showed significant differences between calibration curves with as-received and respirable size fractions for NMAM 7603 and seven for MSHA P-7. The quartz mass measured in 48 samples spiked with respirable fraction silica and kaolinite ranged between 0.28 and 23% (NMAM 7603) and 0.18 and 26% (MSHA P-7) of the expected applied mass when the kaolinite interference was corrected with respirable size fraction kaolinite. This is termed "deviation," not bias, because the applied mass is also subject to unknown variance. Generally, the deviations in the spiked samples are larger when corrected with the as-received size fraction of kaolinite than with the respirable size fraction. Results indicate that if a kaolinite correction with reference material of respirable size fraction is applied in current standard methods for quartz measurement in coal mine dust, the quartz result would be somewhat closer to the true exposure, although the actual mass difference would be small. Most kinds of kaolinite can be used for laboratory calibration, but preferably, the size fraction should be the same as the coal dust being collected.
Reproducibility of preclinical animal research improves with heterogeneity of study samples
Vogt, Lucile; Sena, Emily S.; Würbel, Hanno
2018-01-01
Single-laboratory studies conducted under highly standardized conditions are the gold standard in preclinical animal research. Using simulations based on 440 preclinical studies across 13 different interventions in animal models of stroke, myocardial infarction, and breast cancer, we compared the accuracy of effect size estimates between single-laboratory and multi-laboratory study designs. Single-laboratory studies generally failed to predict effect size accurately, and larger sample sizes rendered effect size estimates even less accurate. By contrast, multi-laboratory designs including as few as 2 to 4 laboratories increased coverage probability by up to 42 percentage points without a need for larger sample sizes. These findings demonstrate that within-study standardization is a major cause of poor reproducibility. More representative study samples are required to improve the external validity and reproducibility of preclinical animal research and to prevent wasting animals and resources for inconclusive research. PMID:29470495
Simulation of Particle Size Effect on Dynamic Properties and Fracture of PTFE-W-Al Composites
NASA Astrophysics Data System (ADS)
Herbold, Eric; Cai, Jing; Benson, David; Nesterenko, Vitali
2007-06-01
Recent investigations of the dynamic compressive strength of cold isostatically pressed (CIP) composites of polytetrafluoroethylene (PTFE), tungsten and aluminum powders show significant differences depending on the size of metallic particles. PTFE and aluminum mixtures are known to be energetic under dynamic and thermal loading. The addition of tungsten increases density and overall strength of the sample. Multi-material Eulerian and arbitrary Lagrangian-Eulerian methods were used for the investigation due to the complexity of the microstructure, relatively large deformations and the ability to handle the formation of free surfaces in a natural manner. The calculations indicate that the observed dependence of sample strength on particle size is due to the formation of force chains under dynamic loading in samples with small particle sizes even at larger porosity in comparison with samples with large grain size and larger density.
Schilirò, T; Alessandria, L; Bonetta, S; Carraro, E; Gilli, G
2016-02-01
To contribute to a greater characterization of the airborne particulate matter's toxicity, size-fractionated PM10 was sampled during different seasons in a polluted urban site in Torino, a northern Italian city. Three main size fractions (PM10 - 3 μm; PM3 - 0.95 μm; PM < 0.95 μm) extracts (organic and aqueous) were assayed with THP-1 cells to evaluate their effects on cell proliferation, LDH activity, TNFα, IL-8 and CYP1A1 expression. The mean PM10 concentrations were statistically different in summer and in winter and the finest fraction PM<0.95 was always higher than the others. Size-fractionated PM10 extracts, sampled in an urban traffic meteorological-chemical station produced size-related toxicological effects in relation to season and particles extraction. The PM summer extracts induced a significant release of LDH compared to winter and produced a size-related effect, with higher values measured with PM10-3. Exposure to size-fractionated PM10 extracts did not induce significant expression of TNFα. IL-8 expression was influenced by exposure to size-fractionated PM10 extracts and statistically significant differences were found between kind of extracts for both seasons. The mean fold increases in CYP1A1 expression were statistically different in summer and in winter; winter fraction extracts produced a size-related effect, in particular for organic samples with higher values measured with PM<0.95 extracts. Our results confirm that the only measure of PM can be misleading for the assessment of air quality moreover we support efforts toward identifying potential effect-based tools (e.g. in vitro test) that could be used in the context of the different monitoring programs. Copyright © 2015 Elsevier Ltd. All rights reserved.
Ranked set sampling: cost and optimal set size.
Nahhas, Ramzi W; Wolfe, Douglas A; Chen, Haiying
2002-12-01
McIntyre (1952, Australian Journal of Agricultural Research 3, 385-390) introduced ranked set sampling (RSS) as a method for improving estimation of a population mean in settings where sampling and ranking of units from the population are inexpensive when compared with actual measurement of the units. Two of the major factors in the usefulness of RSS are the set size and the relative costs of the various operations of sampling, ranking, and measurement. In this article, we consider ranking error models and cost models that enable us to assess the effect of different cost structures on the optimal set size for RSS. For reasonable cost structures, we find that the optimal RSS set sizes are generally larger than had been anticipated previously. These results will provide a useful tool for determining whether RSS is likely to lead to an improvement over simple random sampling in a given setting and, if so, what RSS set size is best to use in this case.
Frictional behaviour of sandstone: A sample-size dependent triaxial investigation
NASA Astrophysics Data System (ADS)
Roshan, Hamid; Masoumi, Hossein; Regenauer-Lieb, Klaus
2017-01-01
Frictional behaviour of rocks from the initial stage of loading to final shear displacement along the formed shear plane has been widely investigated in the past. However the effect of sample size on such frictional behaviour has not attracted much attention. This is mainly related to the limitations in rock testing facilities as well as the complex mechanisms involved in sample-size dependent frictional behaviour of rocks. In this study, a suite of advanced triaxial experiments was performed on Gosford sandstone samples at different sizes and confining pressures. The post-peak response of the rock along the formed shear plane has been captured for the analysis with particular interest in sample-size dependency. Several important phenomena have been observed from the results of this study: a) the rate of transition from brittleness to ductility in rock is sample-size dependent where the relatively smaller samples showed faster transition toward ductility at any confining pressure; b) the sample size influences the angle of formed shear band and c) the friction coefficient of the formed shear plane is sample-size dependent where the relatively smaller sample exhibits lower friction coefficient compared to larger samples. We interpret our results in terms of a thermodynamics approach in which the frictional properties for finite deformation are viewed as encompassing a multitude of ephemeral slipping surfaces prior to the formation of the through going fracture. The final fracture itself is seen as a result of the self-organisation of a sufficiently large ensemble of micro-slip surfaces and therefore consistent in terms of the theory of thermodynamics. This assumption vindicates the use of classical rock mechanics experiments to constrain failure of pressure sensitive rocks and the future imaging of these micro-slips opens an exciting path for research in rock failure mechanisms.
Influence of tree spatial pattern and sample plot type and size on inventory
John-Pascall Berrill; Kevin L. O' Hara
2012-01-01
Sampling with different plot types and sizes was simulated using tree location maps and data collected in three even-aged coast redwood (Sequoia sempervirens) stands selected to represent uniform, random, and clumped spatial patterns of tree locations. Fixed-radius circular plots, belt transects, and variable-radius plots were installed by...
Grain size effect on the permittivity of La1.5Sr0.5NiO4 nanoparticles
NASA Astrophysics Data System (ADS)
Dang Thanh, Tran; Van Hong, Le
2009-09-01
Using the annealing at different temperatures the La1.5Sr0.5NiO4 ceramic samples with different mean grain size were manufactured. Mean grain size (
Phase transformations in a Cu−Cr alloy induced by high pressure torsion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Korneva, Anna, E-mail: a.korniewa@imim.pl; Straumal, Boris; Institut für Nanotechnologie, Karlsruher Institut für Technologie, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen
2016-04-15
Phase transformations induced by high pressure torsion (HPT) at room temperature in two samples of the Cu-0.86 at.% Cr alloy, pre-annealed at 550 °C and 1000 °C, were studied in order to obtain two different initial states for the HPT procedure. Observation of microstructure of the samples before HPT revealed that the sample annealed at 550 °C contained two types of Cr precipitates in the Cu matrix: large particles (size about 500 nm) and small ones (size about 70 nm). The sample annealed at 1000 °C showed only a little fraction of Cr precipitates (size about 2 μm). The subsequentmore » HPT process resulted in the partial dissolution of Cr precipitates in the first sample and dissolution of Cr precipitates with simultaneous decomposition of the supersaturated solid solution in another. However, the resulting microstructure of the samples after HPT was very similar from the standpoint of grain size, phase composition, texture analysis and hardness measurements. - Highlights: • Cu−Cr alloy with two different initial states was deformed by HPT. • Phase transformations in the deformed materials were studied. • SEM, TEM and X-ray diffraction techniques were used for microstructure analysis. • HPT leads to formation the same microstructure independent of the initial state.« less
Atomistic origin of size effects in fatigue behavior of metallic glasses
NASA Astrophysics Data System (ADS)
Sha, Zhendong; Wong, Wei Hin; Pei, Qingxiang; Branicio, Paulo Sergio; Liu, Zishun; Wang, Tiejun; Guo, Tianfu; Gao, Huajian
2017-07-01
While many experiments and simulations on metallic glasses (MGs) have focused on their tensile ductility under monotonic loading, the fatigue mechanisms of MGs under cyclic loading still remain largely elusive. Here we perform molecular dynamics (MD) and finite element simulations of tension-compression fatigue tests in MGs to elucidate their fatigue mechanisms with focus on the sample size effect. Shear band (SB) thickening is found to be the inherent fatigue mechanism for nanoscale MGs. The difference in fatigue mechanisms between macroscopic and nanoscale MGs originates from whether the SB forms partially or fully through the cross-section of the specimen. Furthermore, a qualitative investigation of the sample size effect suggests that small sample size increases the fatigue life while large sample size promotes cyclic softening and necking. Our observations on the size-dependent fatigue behavior can be rationalized by the Gurson model and the concept of surface tension of the nanovoids. The present study sheds light on the fatigue mechanisms of MGs and can be useful in interpreting previous experimental results.
Kidney function endpoints in kidney transplant trials: a struggle for power.
Ibrahim, A; Garg, A X; Knoll, G A; Akbari, A; White, C A
2013-03-01
Kidney function endpoints are commonly used in randomized controlled trials (RCTs) in kidney transplantation (KTx). We conducted this study to estimate the proportion of ongoing RCTs with kidney function endpoints in KTx where the proposed sample size is large enough to detect meaningful differences in glomerular filtration rate (GFR) with adequate statistical power. RCTs were retrieved using the key word "kidney transplantation" from the National Institute of Health online clinical trial registry. Included trials had at least one measure of kidney function tracked for at least 1 month after transplant. We determined the proportion of two-arm parallel trials that had sufficient sample sizes to detect a minimum 5, 7.5 and 10 mL/min difference in GFR between arms. Fifty RCTs met inclusion criteria. Only 7% of the trials were above a sample size of 562, the number needed to detect a minimum 5 mL/min difference between the groups should one exist (assumptions: α = 0.05; power = 80%, 10% loss to follow-up, common standard deviation of 20 mL/min). The result increased modestly to 36% of trials when a minimum 10 mL/min difference was considered. Only a minority of ongoing trials have adequate statistical power to detect between-group differences in kidney function using conventional sample size estimating parameters. For this reason, some potentially effective interventions which ultimately could benefit patients may be abandoned from future assessment. © Copyright 2013 The American Society of Transplantation and the American Society of Transplant Surgeons.
Unequal cluster sizes in stepped-wedge cluster randomised trials: a systematic review
Morris, Tom; Gray, Laura
2017-01-01
Objectives To investigate the extent to which cluster sizes vary in stepped-wedge cluster randomised trials (SW-CRT) and whether any variability is accounted for during the sample size calculation and analysis of these trials. Setting Any, not limited to healthcare settings. Participants Any taking part in an SW-CRT published up to March 2016. Primary and secondary outcome measures The primary outcome is the variability in cluster sizes, measured by the coefficient of variation (CV) in cluster size. Secondary outcomes include the difference between the cluster sizes assumed during the sample size calculation and those observed during the trial, any reported variability in cluster sizes and whether the methods of sample size calculation and methods of analysis accounted for any variability in cluster sizes. Results Of the 101 included SW-CRTs, 48% mentioned that the included clusters were known to vary in size, yet only 13% of these accounted for this during the calculation of the sample size. However, 69% of the trials did use a method of analysis appropriate for when clusters vary in size. Full trial reports were available for 53 trials. The CV was calculated for 23 of these: the median CV was 0.41 (IQR: 0.22–0.52). Actual cluster sizes could be compared with those assumed during the sample size calculation for 14 (26%) of the trial reports; the cluster sizes were between 29% and 480% of that which had been assumed. Conclusions Cluster sizes often vary in SW-CRTs. Reporting of SW-CRTs also remains suboptimal. The effect of unequal cluster sizes on the statistical power of SW-CRTs needs further exploration and methods appropriate to studies with unequal cluster sizes need to be employed. PMID:29146637
On sample size and different interpretations of snow stability datasets
NASA Astrophysics Data System (ADS)
Schirmer, M.; Mitterer, C.; Schweizer, J.
2009-04-01
Interpretations of snow stability variations need an assessment of the stability itself, independent of the scale investigated in the study. Studies on stability variations at a regional scale have often chosen stability tests such as the Rutschblock test or combinations of various tests in order to detect differences in aspect and elevation. The question arose: ‘how capable are such stability interpretations in drawing conclusions'. There are at least three possible errors sources: (i) the variance of the stability test itself; (ii) the stability variance at an underlying slope scale, and (iii) that the stability interpretation might not be directly related to the probability of skier triggering. Various stability interpretations have been proposed in the past that provide partly different results. We compared a subjective one based on expert knowledge with a more objective one based on a measure derived from comparing skier-triggered slopes vs. slopes that have been skied but not triggered. In this study, the uncertainties are discussed and their effects on regional scale stability variations will be quantified in a pragmatic way. An existing dataset with very large sample sizes was revisited. This dataset contained the variance of stability at a regional scale for several situations. The stability in this dataset was determined using the subjective interpretation scheme based on expert knowledge. The question to be answered was how many measurements were needed to obtain similar results (mainly stability differences in aspect or elevation) as with the complete dataset. The optimal sample size was obtained in several ways: (i) assuming a nominal data scale the sample size was determined with a given test, significance level and power, and by calculating the mean and standard deviation of the complete dataset. With this method it can also be determined if the complete dataset consists of an appropriate sample size. (ii) Smaller subsets were created with similar aspect distributions to the large dataset. We used 100 different subsets for each sample size. Statistical variations obtained in the complete dataset were also tested on the smaller subsets using the Mann-Whitney or the Kruskal-Wallis test. For each subset size, the number of subsets were counted in which the significance level was reached. For these tests no nominal data scale was assumed. (iii) For the same subsets described above, the distribution of the aspect median was determined. A count of how often this distribution was substantially different from the distribution obtained with the complete dataset was made. Since two valid stability interpretations were available (an objective and a subjective interpretation as described above), the effect of the arbitrary choice of the interpretation on spatial variability results was tested. In over one third of the cases the two interpretations came to different results. The effect of these differences were studied in a similar method as described in (iii): the distribution of the aspect median was determined for subsets of the complete dataset using both interpretations, compared against each other as well as to the results of the complete dataset. For the complete dataset the two interpretations showed mainly identical results. Therefore the subset size was determined from the point at which the results of the two interpretations converged. A universal result for the optimal subset size cannot be presented since results differed between different situations contained in the dataset. The optimal subset size is thus dependent on stability variation in a given situation, which is unknown initially. There are indications that for some situations even the complete dataset might be not large enough. At a subset size of approximately 25, the significant differences between aspect groups (as determined using the whole dataset) were only obtained in one out of five situations. In some situations, up to 20% of the subsets showed a substantially different distribution of the aspect median. Thus, in most cases, 25 measurements (which can be achieved by six two-person teams in one day) did not allow to draw reliable conclusions.
Pinto-Leite, C M; Rocha, P L B
2012-12-01
Empirical studies using visual search methods to investigate spider communities were conducted with different sampling protocols, including a variety of plot sizes, sampling efforts, and diurnal periods for sampling. We sampled 11 plots ranging in size from 5 by 10 m to 5 by 60 m. In each plot, we computed the total number of species detected every 10 min during 1 hr during the daytime and during the nighttime (0630 hours to 1100 hours, both a.m. and p.m.). We measured the influence of time effort on the measurement of species richness by comparing the curves produced by sample-based rarefaction and species richness estimation (first-order jackknife). We used a general linear model with repeated measures to assess whether the phase of the day during which sampling occurred and the differences in the plot lengths influenced the number of species observed and the number of species estimated. To measure the differences in species composition between the phases of the day, we used a multiresponse permutation procedure and a graphical representation based on nonmetric multidimensional scaling. After 50 min of sampling, we noted a decreased rate of species accumulation and a tendency of the estimated richness curves to reach an asymptote. We did not detect an effect of plot size on the number of species sampled. However, differences in observed species richness and species composition were found between phases of the day. Based on these results, we propose guidelines for visual search for tropical web spiders.
Comparative analyses of basal rate of metabolism in mammals: data selection does matter.
Genoud, Michel; Isler, Karin; Martin, Robert D
2018-02-01
Basal rate of metabolism (BMR) is a physiological parameter that should be measured under strictly defined experimental conditions. In comparative analyses among mammals BMR is widely used as an index of the intensity of the metabolic machinery or as a proxy for energy expenditure. Many databases with BMR values for mammals are available, but the criteria used to select metabolic data as BMR estimates have often varied and the potential effect of this variability has rarely been questioned. We provide a new, expanded BMR database reflecting compliance with standard criteria (resting, postabsorptive state; thermal neutrality; adult, non-reproductive status for females) and examine potential effects of differential selectivity on the results of comparative analyses. The database includes 1739 different entries for 817 species of mammals, compiled from the original sources. It provides information permitting assessment of the validity of each estimate and presents the value closest to a proper BMR for each entry. Using different selection criteria, several alternative data sets were extracted and used in comparative analyses of (i) the scaling of BMR to body mass and (ii) the relationship between brain mass and BMR. It was expected that results would be especially dependent on selection criteria with small sample sizes and with relatively weak relationships. Phylogenetically informed regression (phylogenetic generalized least squares, PGLS) was applied to the alternative data sets for several different clades (Mammalia, Eutheria, Metatheria, or individual orders). For Mammalia, a 'subsampling procedure' was also applied, in which random subsamples of different sample sizes were taken from each original data set and successively analysed. In each case, two data sets with identical sample size and species, but comprising BMR data with different degrees of reliability, were compared. Selection criteria had minor effects on scaling equations computed for large clades (Mammalia, Eutheria, Metatheria), although less-reliable estimates of BMR were generally about 12-20% larger than more-reliable ones. Larger effects were found with more-limited clades, such as sciuromorph rodents. For the relationship between BMR and brain mass the results of comparative analyses were found to depend strongly on the data set used, especially with more-limited, order-level clades. In fact, with small sample sizes (e.g. <100) results often appeared erratic. Subsampling revealed that sample size has a non-linear effect on the probability of a zero slope for a given relationship. Depending on the species included, results could differ dramatically, especially with small sample sizes. Overall, our findings indicate a need for due diligence when selecting BMR estimates and caution regarding results (even if seemingly significant) with small sample sizes. © 2017 Cambridge Philosophical Society.
Improving the accuracy of livestock distribution estimates through spatial interpolation.
Bryssinckx, Ward; Ducheyne, Els; Muhwezi, Bernard; Godfrey, Sunday; Mintiens, Koen; Leirs, Herwig; Hendrickx, Guy
2012-11-01
Animal distribution maps serve many purposes such as estimating transmission risk of zoonotic pathogens to both animals and humans. The reliability and usability of such maps is highly dependent on the quality of the input data. However, decisions on how to perform livestock surveys are often based on previous work without considering possible consequences. A better understanding of the impact of using different sample designs and processing steps on the accuracy of livestock distribution estimates was acquired through iterative experiments using detailed survey. The importance of sample size, sample design and aggregation is demonstrated and spatial interpolation is presented as a potential way to improve cattle number estimates. As expected, results show that an increasing sample size increased the precision of cattle number estimates but these improvements were mainly seen when the initial sample size was relatively low (e.g. a median relative error decrease of 0.04% per sampled parish for sample sizes below 500 parishes). For higher sample sizes, the added value of further increasing the number of samples declined rapidly (e.g. a median relative error decrease of 0.01% per sampled parish for sample sizes above 500 parishes. When a two-stage stratified sample design was applied to yield more evenly distributed samples, accuracy levels were higher for low sample densities and stabilised at lower sample sizes compared to one-stage stratified sampling. Aggregating the resulting cattle number estimates yielded significantly more accurate results because of averaging under- and over-estimates (e.g. when aggregating cattle number estimates from subcounty to district level, P <0.009 based on a sample of 2,077 parishes using one-stage stratified samples). During aggregation, area-weighted mean values were assigned to higher administrative unit levels. However, when this step is preceded by a spatial interpolation to fill in missing values in non-sampled areas, accuracy is improved remarkably. This counts especially for low sample sizes and spatially even distributed samples (e.g. P <0.001 for a sample of 170 parishes using one-stage stratified sampling and aggregation on district level). Whether the same observations apply on a lower spatial scale should be further investigated.
Puls, Robert W.; Eychaner, James H.; Powell, Robert M.
1996-01-01
Investigations at Pinal Creek, Arizona, evaluated routine sampling procedures for determination of aqueous inorganic geochemistry and assessment of contaminant transport by colloidal mobility. Sampling variables included pump type and flow rate, collection under air or nitrogen, and filter pore diameter. During well purging and sample collection, suspended particle size and number as well as dissolved oxygen, temperature, specific conductance, pH, and redox potential were monitored. Laboratory analyses of both unfiltered samples and the filtrates were performed by inductively coupled argon plasma, atomic absorption with graphite furnace, and ion chromatography. Scanning electron microscopy with Energy Dispersive X-ray was also used for analysis of filter particulates. Suspended particle counts consistently required approximately twice as long as the other field-monitored indicators to stabilize. High-flow-rate pumps entrained normally nonmobile particles. Difference in elemental concentrations using different filter-pore sizes were generally not large with only two wells having differences greater than 10 percent in most wells. Similar differences (>10%) were observed for some wells when samples were collected under nitrogen rather than in air. Fe2+/Fe3+ ratios for air-collected samples were smaller than for samples collected under a nitrogen atmosphere, reflecting sampling-induced oxidation.
Le Boedec, Kevin
2016-12-01
According to international guidelines, parametric methods must be chosen for RI construction when the sample size is small and the distribution is Gaussian. However, normality tests may not be accurate at small sample size. The purpose of the study was to evaluate normality test performance to properly identify samples extracted from a Gaussian population at small sample sizes, and assess the consequences on RI accuracy of applying parametric methods to samples that falsely identified the parent population as Gaussian. Samples of n = 60 and n = 30 values were randomly selected 100 times from simulated Gaussian, lognormal, and asymmetric populations of 10,000 values. The sensitivity and specificity of 4 normality tests were compared. Reference intervals were calculated using 6 different statistical methods from samples that falsely identified the parent population as Gaussian, and their accuracy was compared. Shapiro-Wilk and D'Agostino-Pearson tests were the best performing normality tests. However, their specificity was poor at sample size n = 30 (specificity for P < .05: .51 and .50, respectively). The best significance levels identified when n = 30 were 0.19 for Shapiro-Wilk test and 0.18 for D'Agostino-Pearson test. Using parametric methods on samples extracted from a lognormal population but falsely identified as Gaussian led to clinically relevant inaccuracies. At small sample size, normality tests may lead to erroneous use of parametric methods to build RI. Using nonparametric methods (or alternatively Box-Cox transformation) on all samples regardless of their distribution or adjusting, the significance level of normality tests depending on sample size would limit the risk of constructing inaccurate RI. © 2016 American Society for Veterinary Clinical Pathology.
In Situ Sampling of Terrestrial Dust Devils and Implications for Mars
NASA Astrophysics Data System (ADS)
Raack, J.; Reiss, D.; Balme, M. R.; Taj-Eddine, K.; Ori, G. G.
2017-09-01
We report on first very detailed in situ samples of the relative dust load and the vertical grain size distribution of terrestrial dust devils sampled during two field campaigns in Morocco and their implications for Mars. Our measurements imply, i.e., a similar internal structure for sampled dust devils, despite their different strenghts and dimensions; an exponential decreasing of particle size with height; and that between 60 and 70% of all lifted particles can go into atmospheric suspension.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muhammed Shafi, P.; Chandra Bose, A., E-mail: acbose@nitt.edu
2015-05-15
Nanocrystalline tin oxide (SnO{sub 2}) powders with different grain size were prepared by chemical precipitation method. The reaction was carried out by varying the period of hydrolysis and the as-prepared samples were annealed at different temperatures. The samples were characterized using X-ray powder diffractometer and transmission electron microscopy. The microstrain and crystallite size were calculated for all the samples by using Williamson-Hall (W-H) models namely, isotropic strain model (ISM), anisotropic strain model (ASM) and uniform deformation energy density model (UDEDM). The morphology and particle size were determined using TEM micrographs. The directional dependant young’s modulus was modified as an equationmore » relating elastic compliances (s{sub ij}) and Miller indices of the lattice plane (hkl) for tetragonal crystal system and also the equation for elastic compliance in terms of stiffness constants was derived. The changes in crystallite size and microstrain due to lattice defects were observed while varying the hydrolysis time and the annealing temperature. The dependence of crystallite size on lattice strain was studied. The results were correlated with the available studies on electrical properties using impedance spectroscopy.« less
NASA Astrophysics Data System (ADS)
Li, Xiaodan; Ni, Jiaqiang; Zhu, Qingfeng; Su, Hang; Cui, Jianzhong; Zhang, Yifei; Li, Jianzhong
2017-11-01
The AlSi10Mg alloy samples with the size of 14×14×91mm were produced by the selective laser melting (SLM) method in different building direction. The structures and the properties at -70°C of the sample in different direction were investigated. The results show that the structure in different building direction shows different morphology. The fish scale structures distribute on the side along the building direction, and the oval structures distribute on the side vertical to the building direction. Some pores in with the maximum size of 100 μm exist of the structure. And there is no major influence for the build orientation on the tensile properties. The tensile strength and the elongation of the sample in the building direction are 340 Mpa and 11.2 % respectively. And the tensile strength and the elongation of the sample vertical to building direction are 350 Mpa and 13.4 % respectively
Page, G P; Amos, C I; Boerwinkle, E
1998-04-01
We present a test statistic, the quantitative LOD (QLOD) score, for the testing of both linkage and exclusion of quantitative-trait loci in randomly selected human sibships. As with the traditional LOD score, the boundary values of 3, for linkage, and -2, for exclusion, can be used for the QLOD score. We investigated the sample sizes required for inferring exclusion and linkage, for various combinations of linked genetic variance, total heritability, recombination distance, and sibship size, using fixed-size sampling. The sample sizes required for both linkage and exclusion were not qualitatively different and depended on the percentage of variance being linked or excluded and on the total genetic variance. Information regarding linkage and exclusion in sibships larger than size 2 increased as approximately all possible pairs n(n-1)/2 up to sibships of size 6. Increasing the recombination (theta) distance between the marker and the trait loci reduced empirically the power for both linkage and exclusion, as a function of approximately (1-2theta)4.
Random vs. systematic sampling from administrative databases involving human subjects.
Hagino, C; Lo, R J
1998-09-01
Two sampling techniques, simple random sampling (SRS) and systematic sampling (SS), were compared to determine whether they yield similar and accurate distributions for the following four factors: age, gender, geographic location and years in practice. Any point estimate within 7 yr or 7 percentage points of its reference standard (SRS or the entire data set, i.e., the target population) was considered "acceptably similar" to the reference standard. The sampling frame was from the entire membership database of the Canadian Chiropractic Association. The two sampling methods were tested using eight different sample sizes of n (50, 100, 150, 200, 250, 300, 500, 800). From the profile/characteristics, summaries of four known factors [gender, average age, number (%) of chiropractors in each province and years in practice], between- and within-methods chi 2 tests and unpaired t tests were performed to determine whether any of the differences [descriptively greater than 7% or 7 yr] were also statistically significant. The strengths of the agreements between the provincial distributions were quantified by calculating the percent agreements for each (provincial pairwise-comparison methods). Any percent agreement less than 70% was judged to be unacceptable. Our assessments of the two sampling methods (SRS and SS) for the different sample sizes tested suggest that SRS and SS yielded acceptably similar results. Both methods started to yield "correct" sample profiles at approximately the same sample size (n > 200). SS is not only convenient, it can be recommended for sampling from large databases in which the data are listed without any inherent order biases other than alphabetical listing by surname.
Liu, Keshun
2008-11-01
Eleven distillers dried grains with solubles (DDGS), processed from yellow corn, were collected from different ethanol processing plants in the US Midwest area. Particle size distribution (PSD) by mass of each sample was determined using a series of six selected US standard sieves: Nos. 8, 12, 18, 35, 60, and 100, and a pan. The original sample and sieve sized fractions were measured for surface color and contents of moisture, protein, oil, ash, and starch. Total carbohydrate (CHO) and total non-starch CHO were also calculated. Results show that there was a great variation in composition and color among DDGS from different plants. Surprisingly, a few DDGS samples contained unusually high amounts of residual starch (11.1-17.6%, dry matter basis, vs. about 5% of the rest), presumably resulting from modified processing methods. Particle size of DDGS varied greatly within a sample and PSD varied greatly among samples. The 11 samples had a mean value of 0.660mm for the geometric mean diameter (dgw) of particles and a mean value of 0.440mm for the geometric standard deviation (Sgw) of particle diameters by mass. The majority had a unimodal PSD, with a mode in the size class between 0.5 and 1.0mm. Although PSD and color parameters had little correlation with composition of whole DDGS samples, distribution of nutrients as well as color attributes correlated well with PSD. In sieved fractions, protein content, L and a color values negatively while contents of oil and total CHO positively correlated with particle size. It is highly feasible to fractionate DDGS for compositional enrichment based on particle size, while the extent of PSD can serve as an index for potential of DDGS fractionation. The above information should be a vital addition to quality and baseline data of DDGS.
Kent, Peter; Boyle, Eleanor; Keating, Jennifer L; Albert, Hanne B; Hartvigsen, Jan
2017-02-01
To quantify variability in the results of statistical analyses based on contingency tables and discuss the implications for the choice of sample size for studies that derive clinical prediction rules. An analysis of three pre-existing sets of large cohort data (n = 4,062-8,674) was performed. In each data set, repeated random sampling of various sample sizes, from n = 100 up to n = 2,000, was performed 100 times at each sample size and the variability in estimates of sensitivity, specificity, positive and negative likelihood ratios, posttest probabilities, odds ratios, and risk/prevalence ratios for each sample size was calculated. There were very wide, and statistically significant, differences in estimates derived from contingency tables from the same data set when calculated in sample sizes below 400 people, and typically, this variability stabilized in samples of 400-600 people. Although estimates of prevalence also varied significantly in samples below 600 people, that relationship only explains a small component of the variability in these statistical parameters. To reduce sample-specific variability, contingency tables should consist of 400 participants or more when used to derive clinical prediction rules or test their performance. Copyright © 2016 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Videtich, Patricia E.; Neal, William J.
2012-01-01
Using sieving and sample "unknowns" for instructional grain-size analysis and interpretation of sands in undergraduate sedimentology courses has advantages over other techniques. Students (1) learn to calculate and use statistics; (2) visually observe differences in the grain-size fractions, thereby developing a sense of specific size…
J. L. Willers; J. M. McKinion; J. N. Jenkins
2006-01-01
Simulation was employed to create stratified simple random samples of different sample unit sizes to represent tarnished plant bug abundance at different densities within various habitats of simulated cotton fields. These samples were used to investigate dispersion patterns of this cotton insect. It was found that the assessment of spatial pattern varied as a function...
ERIC Educational Resources Information Center
Dykiert, Dominika; Gale, Catharine R.; Deary, Ian J.
2009-01-01
This study investigated the possibility that apparent sex differences in IQ are at least partly created by the degree of sample restriction from the baseline population. We used a nationally representative sample, the 1970 British Cohort Study. Sample sizes varied from 6518 to 11,389 between data-collection sweeps. Principal components analysis of…
Simulation of Particle Size Effect on Dynamic Properties and Fracture of PTFE-W-Al Composites
NASA Astrophysics Data System (ADS)
Herbold, E. B.; Cai, J.; Benson, D. J.; Nesterenko, V. F.
2007-12-01
Recent investigations of the dynamic compressive strength of cold isostatically pressed composites of polytetrafluoroethylene (PTFE), tungsten (W) and aluminum (Al) powders show significant differences depending on the size of metallic particles. The addition of W increases the density and changes the overall strength of the sample depending on the size of W particles. To investigate relatively large deformations, multi-material Eulerian and arbitrary Lagrangian-Eulerian methods, which have the ability to efficiently handle the formation of free surfaces, were used. The calculations indicate that the increased sample strength with fine metallic particles is due to the dynamic formation of force chains. This phenomenon occurs for samples with a higher porosity of the PTFE matrix compared to samples with larger particle size of W and a higher density PTFE matrix.
NASA Astrophysics Data System (ADS)
Jux, Maximilian; Finke, Benedikt; Mahrholz, Thorsten; Sinapius, Michael; Kwade, Arno; Schilde, Carsten
2017-04-01
Several epoxy Al(OH)O (boehmite) dispersions in an epoxy resin are produced in a kneader to study the mechanistic correlation between the nanoparticle size and mechanical properties of the prepared nanocomposites. The agglomerate size is set by a targeted variation in solid content and temperature during dispersion, resulting in a different level of stress intensity and thus a different final agglomerate size during the process. The suspension viscosity was used for the estimation of stress energy in laminar shear flow. Agglomerate size measurements are executed via dynamic light scattering to ensure the quality of the produced dispersions. Furthermore, various nanocomposite samples are prepared for three-point bending, tension, and fracture toughness tests. The screening of the size effect is executed with at least seven samples per agglomerate size and test method. The variation of solid content is found to be a reliable method to adjust the agglomerate size between 138-354 nm during dispersion. The size effect on the Young's modulus and the critical stress intensity is only marginal. Nevertheless, there is a statistically relevant trend showing a linear increase with a decrease in agglomerate size. In contrast, the size effect is more dominant to the sample's strain and stress at failure. Unlike microscaled agglomerates or particles, which lead to embrittlement of the composite material, nanoscaled agglomerates or particles cause the composite elongation to be nearly of the same level as the base material. The observed effect is valid for agglomerate sizes between 138-354 nm and a particle mass fraction of 10 wt%.
Sample size calculation for stepped wedge and other longitudinal cluster randomised trials.
Hooper, Richard; Teerenstra, Steven; de Hoop, Esther; Eldridge, Sandra
2016-11-20
The sample size required for a cluster randomised trial is inflated compared with an individually randomised trial because outcomes of participants from the same cluster are correlated. Sample size calculations for longitudinal cluster randomised trials (including stepped wedge trials) need to take account of at least two levels of clustering: the clusters themselves and times within clusters. We derive formulae for sample size for repeated cross-section and closed cohort cluster randomised trials with normally distributed outcome measures, under a multilevel model allowing for variation between clusters and between times within clusters. Our formulae agree with those previously described for special cases such as crossover and analysis of covariance designs, although simulation suggests that the formulae could underestimate required sample size when the number of clusters is small. Whether using a formula or simulation, a sample size calculation requires estimates of nuisance parameters, which in our model include the intracluster correlation, cluster autocorrelation, and individual autocorrelation. A cluster autocorrelation less than 1 reflects a situation where individuals sampled from the same cluster at different times have less correlated outcomes than individuals sampled from the same cluster at the same time. Nuisance parameters could be estimated from time series obtained in similarly clustered settings with the same outcome measure, using analysis of variance to estimate variance components. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
This paper is the result of a collaboration to assess effects of size fractionated PM from different locations on murine pulmonary inflammatory responses. In the course of this, they also determined the chemical makeup of each of the samples.
A Naturalistic Study of Driving Behavior in Older Adults and Preclinical Alzheimer Disease.
Babulal, Ganesh M; Stout, Sarah H; Benzinger, Tammie L S; Ott, Brian R; Carr, David B; Webb, Mollie; Traub, Cindy M; Addison, Aaron; Morris, John C; Warren, David K; Roe, Catherine M
2017-01-01
A clinical consequence of symptomatic Alzheimer's disease (AD) is impaired driving performance. However, decline in driving performance may begin in the preclinical stage of AD. We used a naturalistic driving methodology to examine differences in driving behavior over one year in a small sample of cognitively normal older adults with ( n = 10) and without ( n = 10) preclinical AD. As expected with a small sample size, there were no statistically significant differences between the two groups, but older adults with preclinical AD drove less often, were less likely to drive at night, and had fewer aggressive behaviors such as hard braking, speeding, and sudden acceleration. The sample size required to power a larger study to determine differences was calculated.
Study of Cost of Distance Education Institutes with Different Size Classes in India.
ERIC Educational Resources Information Center
Datt, Ruddar
A study of the cost of distance education institutes in India with different size classes involved nine institutions. The sample included 47 percent of total enrollment in distance education institutions in India. The study was restricted to recurring costs and examined the shares of different components of costs and the sources of funding. It…
Rajasekaran, S; Kanna, Rishi Mugesh; Reddy, Ranjani Raja; Natesan, Senthil; Raveendran, Muthuraja; Cheung, Kenneth M C; Chan, Danny; Kao, Patrick Y P; Yee, Anita; Shetty, Ajoy Prasad
2016-11-01
Prospective genetic association study. The aim of this study was to document the variations in the genetic associations, when different magnetic resonance imaging (MRI) phenotypes, age stratification, cohort size, and sequence of cohort inclusion are varied in the same study population. Genetic associations with disc degeneration have shown high inconsistency, generally attributed to hereditary factors and ethnic variations. However, the effect of different phenotypes, size of the study population, age of the cohort, etc have not been documented clearly. Seventy-one single-nucleotide polymorphisms (SNPs) of 41 candidate genes were correlated to six MRI markers of disc degeneration (annular tears, Pfirmann grading, Schmorl nodes, Modic changes, Total Endplate Damage score, and disc bulge) in 809 patients with back pain and/or sciatica. In the same study group, the correlations were then retested for different age groups, different sample, size and sequence of subject inclusion (first 404 and the second 405) and the differences documented. The mean age of population (M: 455, F: 354) was 36.7 ± 10.8 years. Different genetic associations were found with different phenotypes: disc bulge with three SNPs of CILP; annular tears with rs2249350 of ADAMTS5 and rs11247361 IGF1R; modic changes with VDR and MMP20; Pfirmann grading with three SNPs of MMP20 and Schmorl node with SNPs of CALM1 and FN1 and none with Total End Plate Score.Subgroup analysis based on three age groups and dividing the total population into two groups also completely changed the associations for all the six radiographic parameters. In the same study population, SNP associations completely change with different phenotypes. Variations in age, inclusion sequence, and sample size resulted in change of genetic associations. Our study questions the validity of previous studies and necessitates the need for standardizing the description of disc degeneration, phenotype selection, study sample size, age, and other variables in future studies. 4.
Lombardo, Marco; Serrao, Sebastiano; Lombardo, Giuseppe
2014-01-01
Purpose To investigate the influence of various technical factors on the variation of cone packing density estimates in adaptive optics flood illuminated retinal images. Methods Adaptive optics images of the photoreceptor mosaic were obtained in fifteen healthy subjects. The cone density and Voronoi diagrams were assessed in sampling windows of 320×320 µm, 160×160 µm and 64×64 µm at 1.5 degree temporal and superior eccentricity from the preferred locus of fixation (PRL). The technical factors that have been analyzed included the sampling window size, the corrected retinal magnification factor (RMFcorr), the conversion from radial to linear distance from the PRL, the displacement between the PRL and foveal center and the manual checking of cone identification algorithm. Bland-Altman analysis was used to assess the agreement between cone density estimated within the different sampling window conditions. Results The cone density declined with decreasing sampling area and data between areas of different size showed low agreement. A high agreement was found between sampling areas of the same size when comparing density calculated with or without using individual RMFcorr. The agreement between cone density measured at radial and linear distances from the PRL and between data referred to the PRL or the foveal center was moderate. The percentage of Voronoi tiles with hexagonal packing arrangement was comparable between sampling areas of different size. The boundary effect, presence of any retinal vessels, and the manual selection of cones missed by the automated identification algorithm were identified as the factors influencing variation of cone packing arrangements in Voronoi diagrams. Conclusions The sampling window size is the main technical factor that influences variation of cone density. Clear identification of each cone in the image and the use of a large buffer zone are necessary to minimize factors influencing variation of Voronoi diagrams of the cone mosaic. PMID:25203681
Lombardo, Marco; Serrao, Sebastiano; Lombardo, Giuseppe
2014-01-01
To investigate the influence of various technical factors on the variation of cone packing density estimates in adaptive optics flood illuminated retinal images. Adaptive optics images of the photoreceptor mosaic were obtained in fifteen healthy subjects. The cone density and Voronoi diagrams were assessed in sampling windows of 320×320 µm, 160×160 µm and 64×64 µm at 1.5 degree temporal and superior eccentricity from the preferred locus of fixation (PRL). The technical factors that have been analyzed included the sampling window size, the corrected retinal magnification factor (RMFcorr), the conversion from radial to linear distance from the PRL, the displacement between the PRL and foveal center and the manual checking of cone identification algorithm. Bland-Altman analysis was used to assess the agreement between cone density estimated within the different sampling window conditions. The cone density declined with decreasing sampling area and data between areas of different size showed low agreement. A high agreement was found between sampling areas of the same size when comparing density calculated with or without using individual RMFcorr. The agreement between cone density measured at radial and linear distances from the PRL and between data referred to the PRL or the foveal center was moderate. The percentage of Voronoi tiles with hexagonal packing arrangement was comparable between sampling areas of different size. The boundary effect, presence of any retinal vessels, and the manual selection of cones missed by the automated identification algorithm were identified as the factors influencing variation of cone packing arrangements in Voronoi diagrams. The sampling window size is the main technical factor that influences variation of cone density. Clear identification of each cone in the image and the use of a large buffer zone are necessary to minimize factors influencing variation of Voronoi diagrams of the cone mosaic.
Performance of a Line Loss Correction Method for Gas Turbine Emission Measurements
NASA Astrophysics Data System (ADS)
Hagen, D. E.; Whitefield, P. D.; Lobo, P.
2015-12-01
International concern for the environmental impact of jet engine exhaust emissions in the atmosphere has led to increased attention on gas turbine engine emission testing. The Society of Automotive Engineers Aircraft Exhaust Emissions Measurement Committee (E-31) has published an Aerospace Information Report (AIR) 6241 detailing the sampling system for the measurement of non-volatile particulate matter from aircraft engines, and is developing an Aerospace Recommended Practice (ARP) for methodology and system specification. The Missouri University of Science and Technology (MST) Center for Excellence for Aerospace Particulate Emissions Reduction Research has led numerous jet engine exhaust sampling campaigns to characterize emissions at different locations in the expanding exhaust plume. Particle loss, due to various mechanisms, occurs in the sampling train that transports the exhaust sample from the engine exit plane to the measurement instruments. To account for the losses, both the size dependent penetration functions and the size distribution of the emitted particles need to be known. However in the proposed ARP, particle number and mass are measured, but size is not. Here we present a methodology to generate number and mass correction factors for line loss, without using direct size measurement. A lognormal size distribution is used to represent the exhaust aerosol at the engine exit plane and is defined by the measured number and mass at the downstream end of the sample train. The performance of this line loss correction is compared to corrections based on direct size measurements using data taken by MST during numerous engine test campaigns. The experimental uncertainty in these correction factors is estimated. Average differences between the line loss correction method and size based corrections are found to be on the order of 10% for number and 2.5% for mass.
Mili, Sami; Ennouri, Rym; Dhib, Amel; Laouar, Houcine; Missaoui, Hechmi; Aleya, Lotfi
2016-06-01
To monitor and assess the state of Tunisian freshwater fisheries, two surveys were undertaken at Ghezala and Lahjar reservoirs. Samples were taken in April and May 2013, a period when the fish catchability is high. The selected reservoirs have different surface areas and bathymetries. Using multi-mesh gill nets (EN 14575 amended) designed for sampling fish in lakes, standard fishing methods were applied to estimate species composition, abundance, biomass, and size distribution. Four species were caught in the two reservoirs: barbel, mullet, pike-perch, and roach. Fish abundance showed significant change according to sampling sites, depth strata, and the different mesh sizes used. From the reservoir to the tributary, it was concluded that fish biomass distribution was governed by depth and was most abundant in the upper water layers. Species size distribution differed significantly between the two reservoirs, exceeding the length at first maturity. Species composition and abundance were greater in Lahjar reservoir than in Ghezala. Both reservoirs require support actions to improve fish productivity.
Sepúlveda, Nuno; Drakeley, Chris
2015-04-03
In the last decade, several epidemiological studies have demonstrated the potential of using seroprevalence (SP) and seroconversion rate (SCR) as informative indicators of malaria burden in low transmission settings or in populations on the cusp of elimination. However, most of studies are designed to control ensuing statistical inference over parasite rates and not on these alternative malaria burden measures. SP is in essence a proportion and, thus, many methods exist for the respective sample size determination. In contrast, designing a study where SCR is the primary endpoint, is not an easy task because precision and statistical power are affected by the age distribution of a given population. Two sample size calculators for SCR estimation are proposed. The first one consists of transforming the confidence interval for SP into the corresponding one for SCR given a known seroreversion rate (SRR). The second calculator extends the previous one to the most common situation where SRR is unknown. In this situation, data simulation was used together with linear regression in order to study the expected relationship between sample size and precision. The performance of the first sample size calculator was studied in terms of the coverage of the confidence intervals for SCR. The results pointed out to eventual problems of under or over coverage for sample sizes ≤250 in very low and high malaria transmission settings (SCR ≤ 0.0036 and SCR ≥ 0.29, respectively). The correct coverage was obtained for the remaining transmission intensities with sample sizes ≥ 50. Sample size determination was then carried out for cross-sectional surveys using realistic SCRs from past sero-epidemiological studies and typical age distributions from African and non-African populations. For SCR < 0.058, African studies require a larger sample size than their non-African counterparts in order to obtain the same precision. The opposite happens for the remaining transmission intensities. With respect to the second sample size calculator, simulation unravelled the likelihood of not having enough information to estimate SRR in low transmission settings (SCR ≤ 0.0108). In that case, the respective estimates tend to underestimate the true SCR. This problem is minimized by sample sizes of no less than 500 individuals. The sample sizes determined by this second method highlighted the prior expectation that, when SRR is not known, sample sizes are increased in relation to the situation of a known SRR. In contrast to the first sample size calculation, African studies would now require lesser individuals than their counterparts conducted elsewhere, irrespective of the transmission intensity. Although the proposed sample size calculators can be instrumental to design future cross-sectional surveys, the choice of a particular sample size must be seen as a much broader exercise that involves weighting statistical precision with ethical issues, available human and economic resources, and possible time constraints. Moreover, if the sample size determination is carried out on varying transmission intensities, as done here, the respective sample sizes can also be used in studies comparing sites with different malaria transmission intensities. In conclusion, the proposed sample size calculators are a step towards the design of better sero-epidemiological studies. Their basic ideas show promise to be applied to the planning of alternative sampling schemes that may target or oversample specific age groups.
Laser Diffraction Techniques Replace Sieving for Lunar Soil Particle Size Distribution Data
NASA Technical Reports Server (NTRS)
Cooper, Bonnie L.; Gonzalez, C. P.; McKay, D. S.; Fruland, R. L.
2012-01-01
Sieving was used extensively until 1999 to determine the particle size distribution of lunar samples. This method is time-consuming, and requires more than a gram of material in order to obtain a result in which one may have confidence. This is demonstrated by the difference in geometric mean and median for samples measured by [1], in which a 14-gram sample produced a geometric mean of approx.52 micrometers, whereas two other samples of 1.5 grams resulted in gave means of approx.63 and approx.69 micrometers. Sample allocations for sieving are typically much smaller than a gram, and many of the sample allocations received by our lab are 0.5 to 0.25 grams in mass. Basu [2] has described how the finest fraction of the soil is easily lost in the sieving process, and this effect is compounded when sample sizes are small.
Investigation of element distributions in Luna-16 regolith
NASA Astrophysics Data System (ADS)
Kuznetsov, R. A.; Lure, B. G.; Minevich, V. Ia.; Stiuf, V. I.; Pankratov, V. B.
1981-03-01
The concentrations of 32 elements in fractions of different grain sizes in the samples of the lunar regolith brought back by Luna-16 are determined by means of neutron activation analysis. Four groups of elements are distinguished on the basis of the variations of their concentration with grain size, and concentration variations of the various elements with sample depth are also noted. Chemical leaching of the samples combined with neutron activation also reveals differences in element concentrations in the water soluble, metallic, sulphide, phosphate, rare mineral and rock phases of the samples. In particular, the rare earth elements are observed to be depleted in the regolith with respect to chondritic values, and to be concentrated in the phase extracted with 14 M HNO3.
Norris, Darren; Fortin, Marie-Josée; Magnusson, William E.
2014-01-01
Background Ecological monitoring and sampling optima are context and location specific. Novel applications (e.g. biodiversity monitoring for environmental service payments) call for renewed efforts to establish reliable and robust monitoring in biodiversity rich areas. As there is little information on the distribution of biodiversity across the Amazon basin, we used altitude as a proxy for biological variables to test whether meso-scale variation can be adequately represented by different sample sizes in a standardized, regular-coverage sampling arrangement. Methodology/Principal Findings We used Shuttle-Radar-Topography-Mission digital elevation values to evaluate if the regular sampling arrangement in standard RAPELD (rapid assessments (“RAP”) over the long-term (LTER [“PELD” in Portuguese])) grids captured patters in meso-scale spatial variation. The adequacy of different sample sizes (n = 4 to 120) were examined within 32,325 km2/3,232,500 ha (1293×25 km2 sample areas) distributed across the legal Brazilian Amazon. Kolmogorov-Smirnov-tests, correlation and root-mean-square-error were used to measure sample representativeness, similarity and accuracy respectively. Trends and thresholds of these responses in relation to sample size and standard-deviation were modeled using Generalized-Additive-Models and conditional-inference-trees respectively. We found that a regular arrangement of 30 samples captured the distribution of altitude values within these areas. Sample size was more important than sample standard deviation for representativeness and similarity. In contrast, accuracy was more strongly influenced by sample standard deviation. Additionally, analysis of spatially interpolated data showed that spatial patterns in altitude were also recovered within areas using a regular arrangement of 30 samples. Conclusions/Significance Our findings show that the logistically feasible sample used in the RAPELD system successfully recovers meso-scale altitudinal patterns. This suggests that the sample size and regular arrangement may also be generally appropriate for quantifying spatial patterns in biodiversity at similar scales across at least 90% (≈5 million km2) of the Brazilian Amazon. PMID:25170894
Influence of multidroplet size distribution on icing collection efficiency
NASA Technical Reports Server (NTRS)
Chang, H.-P.; Kimble, K. R.; Frost, W.; Shaw, R. J.
1983-01-01
Calculation of collection efficiencies of two-dimensional airfoils for a monodispersed droplet icing cloud and a multidispersed droplet is carried out. Comparison is made with the experimental results reported in the NACA Technical Note series. The results of the study show considerably improved agreement with experiment when multidroplet size distributions are employed. The study then investigates the effect of collection efficiency on airborne particle droplet size sampling instruments. The biased effect introduced due to sampling from different collection volumes is predicted.
Azizi, Susan; Mohamad, Rosfarizan; Mahdavi Shahri, Mahnaz
2017-02-16
In this paper, a green microwave-assisted combustion approach to synthesize ZnO-NPs using zinc nitrate and Citrullus colocynthis (L.) Schrad (fruit, seed and pulp) extracts as bio-fuels is reported. The structure, optical, and colloidal properties of the synthesized ZnO-NP samples were studied. Results illustrate that the morphology and particle size of the ZnO samples are different and depend on the bio-fuel. The XRD results revealed that hexagonal wurtzite ZnO-NPs with mean particle size of 27-85 nm were produced by different bio-fuels. The optical band gap was increased from 3.25 to 3.40 eV with the decreasing of particle size. FTIR results showed some differences in the surface structures of the as-synthesized ZnO-NP samples. This led to differences in the zeta potential, hydrodynamic size, and more significantly, antioxidant activity through scavenging of 1, 1-Diphenyl-2-picrylhydrazyl (DPPH) free radicals. In in vitro cytotoxicity studies on 3T3 cells, a dose dependent toxicity with non-toxic effect of concentration below 0.26 mg/mL was shown for ZnO-NP samples. Furthermore, the as-synthesized ZnO-NPs inhibited the growth of medically significant pathogenic gram-positive ( Bacillus subtilis and Methicillin-resistant Staphylococcus aurous ) and gram-negative ( Peseudomonas aeruginosa and Escherichia coli ) bacteria. This study provides a simple, green and efficient approach to produce ZnO nanoparticles for various applications.
Heating efficiency dependency on size and morphology of magnetite nanoparticles
NASA Astrophysics Data System (ADS)
Parekh, Kinnari; Parmar, Harshida; Sharma, Vinay; Ramanujan, R. V.
2018-04-01
Different size magnetite nanoparticles ranging from superparamagnetic (9 nm) to single domain (27 nm) and multi domain (53 nm) were synthesized using chemical route. Morphology of these particles as seen from TEM images indicates shape change from spherical to cubic with the growth of particles. The saturation magnetization (σs) and Specific Loss Power (SLP) showed maximum for single domain size, 72 emu/g and 102 W/g, respectively then those of multi domain size particles. These samples show higher SLP at relatively low concentration, low frequency and low amplitude compared to samples prepared by other routes.
The late Neandertal supraorbital fossils from Vindija Cave, Croatia: a biased sample?
Ahern, James C M; Lee, Sang-Hee; Hawks, John D
2002-09-01
The late Neandertal sample from Vindija (Croatia) has been described as transitional between the earlier Central European Neandertals from Krapina (Croatia) and modern humans. However, the morphological differences indicating this transition may rather be the result of different sex and/or age compositions between the samples. This study tests the hypothesis that the metric differences between the Krapina and Vindija supraorbital samples are due to sampling bias. We focus upon the supraorbital region because past studies have posited this region as particularly indicative of the Vindija sample's transitional nature. Furthermore, the supraorbital region varies significantly with both age and sex. We analyzed four chords and two derived indices of supraorbital torus form as defined by Smith & Ranyard (1980, Am. J. phys. Anthrop.93, pp. 589-610). For each variable, we analyzed relative sample bias of the Krapina and Vindija samples using three sampling methods. In order to test the hypothesis that the Vindija sample contains an over-representation of females and/or young while the Krapina sample is normal or also female/young biased, we determined the probability of drawing a sample of the same size as and with a mean equal to or less than Vindija's from a Krapina-based population. In order to test the hypothesis that the Vindija sample is female/young biased while the Krapina sample is male/old biased, we determined the probability of drawing a sample of the same size as and with a mean equal or less than Vindija's from a generated population whose mean is halfway between Krapina's and Vindija's. Finally, in order to test the hypothesis that the Vindija sample is normal while the Krapina sample contains an over-representation of males and/or old, we determined the probability of drawing a sample of the same size as and with a mean equal to or greater than Krapina's from a Vindija-based population. Unless we assume that the Vindija sample is female/young and the Krapina sample is male/old biased, our results falsify the hypothesis that the metric differences between the Krapina and Vindija samples are due to sample bias.
Vaeth, Michael; Skovlund, Eva
2004-06-15
For a given regression problem it is possible to identify a suitably defined equivalent two-sample problem such that the power or sample size obtained for the two-sample problem also applies to the regression problem. For a standard linear regression model the equivalent two-sample problem is easily identified, but for generalized linear models and for Cox regression models the situation is more complicated. An approximately equivalent two-sample problem may, however, also be identified here. In particular, we show that for logistic regression and Cox regression models the equivalent two-sample problem is obtained by selecting two equally sized samples for which the parameters differ by a value equal to the slope times twice the standard deviation of the independent variable and further requiring that the overall expected number of events is unchanged. In a simulation study we examine the validity of this approach to power calculations in logistic regression and Cox regression models. Several different covariate distributions are considered for selected values of the overall response probability and a range of alternatives. For the Cox regression model we consider both constant and non-constant hazard rates. The results show that in general the approach is remarkably accurate even in relatively small samples. Some discrepancies are, however, found in small samples with few events and a highly skewed covariate distribution. Comparison with results based on alternative methods for logistic regression models with a single continuous covariate indicates that the proposed method is at least as good as its competitors. The method is easy to implement and therefore provides a simple way to extend the range of problems that can be covered by the usual formulas for power and sample size determination. Copyright 2004 John Wiley & Sons, Ltd.
Wildt, Signe; Krag, Aleksander; Gluud, Liselotte
2011-01-01
Objectives To evaluate the adequacy of reporting of protocols for randomised trials on diseases of the digestive system registered in http://ClinicalTrials.gov and the consistency between primary outcomes, secondary outcomes and sample size specified in http://ClinicalTrials.gov and published trials. Methods Randomised phase III trials on adult patients with gastrointestinal diseases registered before January 2009 in http://ClinicalTrials.gov were eligible for inclusion. From http://ClinicalTrials.gov all data elements in the database required by the International Committee of Medical Journal Editors (ICMJE) member journals were extracted. The subsequent publications for registered trials were identified. For published trials, data concerning publication date, primary and secondary endpoint, sample size, and whether the journal adhered to ICMJE principles were extracted. Differences between primary and secondary outcomes, sample size and sample size calculations data in http://ClinicalTrials.gov and in the published paper were registered. Results 105 trials were evaluated. 66 trials (63%) were published. 30% of trials were registered incorrectly after their completion date. Several data elements of the required ICMJE data list were not filled in, with missing data in 22% and 11%, respectively, of cases concerning the primary outcome measure and sample size. In 26% of the published papers, data on sample size calculations were missing and discrepancies between sample size reporting in http://ClinicalTrials.gov and published trials existed. Conclusion The quality of registration of randomised controlled trials still needs improvement.
Required sample size for monitoring stand dynamics in strict forest reserves: a case study
Diego Van Den Meersschaut; Bart De Cuyper; Kris Vandekerkhove; Noel Lust
2000-01-01
Stand dynamics in European strict forest reserves are commonly monitored using inventory densities of 5 to 15 percent of the total surface. The assumption that these densities guarantee a representative image of certain parameters is critically analyzed in a case study for the parameters basal area and stem number. The required sample sizes for different accuracy and...
"Magnitude-based inference": a statistical review.
Welsh, Alan H; Knight, Emma J
2015-04-01
We consider "magnitude-based inference" and its interpretation by examining in detail its use in the problem of comparing two means. We extract from the spreadsheets, which are provided to users of the analysis (http://www.sportsci.org/), a precise description of how "magnitude-based inference" is implemented. We compare the implemented version of the method with general descriptions of it and interpret the method in familiar statistical terms. We show that "magnitude-based inference" is not a progressive improvement on modern statistics. The additional probabilities introduced are not directly related to the confidence interval but, rather, are interpretable either as P values for two different nonstandard tests (for different null hypotheses) or as approximate Bayesian calculations, which also lead to a type of test. We also discuss sample size calculations associated with "magnitude-based inference" and show that the substantial reduction in sample sizes claimed for the method (30% of the sample size obtained from standard frequentist calculations) is not justifiable so the sample size calculations should not be used. Rather than using "magnitude-based inference," a better solution is to be realistic about the limitations of the data and use either confidence intervals or a fully Bayesian analysis.
Photographic techniques for characterizing streambed particle sizes
Whitman, Matthew S.; Moran, Edward H.; Ourso, Robert T.
2003-01-01
We developed photographic techniques to characterize coarse (>2-mm) and fine (≤2-mm) streambed particle sizes in 12 streams in Anchorage, Alaska. Results were compared with current sampling techniques to assess which provided greater sampling efficiency and accuracy. The streams sampled were wadeable and contained gravel—cobble streambeds. Gradients ranged from about 5% at the upstream sites to about 0.25% at the downstream sites. Mean particle sizes and size-frequency distributions resulting from digitized photographs differed significantly from those resulting from Wolman pebble counts for five sites in the analysis. Wolman counts were biased toward selecting larger particles. Photographic analysis also yielded a greater number of measured particles (mean = 989) than did the Wolman counts (mean = 328). Stream embeddedness ratings assigned from field and photographic observations were significantly different at 5 of the 12 sites, although both types of ratings showed a positive relationship with digitized surface fines. Visual estimates of embeddedness and digitized surface fines may both be useful indicators of benthic conditions, but digitizing surface fines produces quantitative rather than qualitative data. Benefits of the photographic techniques include reduced field time, minimal streambed disturbance, convenience of postfield processing, easy sample archiving, and improved accuracy and replication potential.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Correa, E. L., E-mail: eduardo.correa@usp.br; Bosch-Santos, B.; Cavalcante, F. H. M.
2016-05-15
The magnetic behavior of Gd{sub 2}O{sub 3} nanoparticles, produced by thermal decomposition method and subsequently annealed at different temperatures, was investigated by magnetization measurements and, at an atomic level, by perturbed γ − γ angular correlation (PAC) spectroscopy measuring hyperfine interactions at {sup 111}In({sup 111}Cd) probe nuclei. Nanoparticle structure, size and shape were characterized by X-ray diffraction (XRD) and Transmission Electron Microscopy (TEM). Magnetization measurements were carried out to characterize the paramagnetic behavior of the samples. XRD results show that all samples crystallize in the cubic-C form of the bixbyite structure with space group Ia3. TEM images showed that particlesmore » annealed at 873 K present particles with highly homogeneous sizes in the range from 5 nm to 10 nm and those annealed at 1273 K show particles with quite different sizes from 5 nm to 100 nm, with a wide size distribution. PAC and magnetization results show that samples annealed at 873 and 1273 K are paramagnetic. Magnetization measurements show no indication of blocking temperatures for all samples down to 2 K and the presence of antiferromagnetic correlations.« less
Annual cycle of size-resolved organic aerosol characterization in an urbanized desert environment
NASA Astrophysics Data System (ADS)
Cahill, Thomas M.
2013-06-01
Studies of size-resolved organic speciation of aerosols are still relatively rare and are generally only conducted over short durations. However, size-resolved organic data can both suggest possible sources of the aerosols and identify the human exposure to the chemicals since different aerosol sizes have different lung capture efficiencies. The objective of this study was to conduct size-resolved organic aerosol speciation for a calendar year in Phoenix, Arizona to determine the seasonal variations in both chemical concentrations and size profiles. The results showed large seasonal differences in combustion pollutants where the highest concentrations were observed in winter. Summertime aerosols have a greater proportion of biological compounds (e.g. sugars and fatty acids) and the biological compounds represent the largest fraction of the organic compounds detected. These results suggest that standard organic carbon (OC) measurements might be heavily influenced by primary biological compounds particularly if the samples are PM10 and TSP samples. Several large dust storms did not significantly alter the organic aerosol profile since Phoenix resides in a dusty desert environment, so the soil and plant tracer of trehalose was almost always present. The aerosol size profiles showed that PAHs were generally most abundant in the smallest aerosol size fractions, which are most likely to be captured by the lung, while the biological compounds were almost exclusively found in the coarse size fraction.
ERIC Educational Resources Information Center
Olneck, Michael R.; Bills, David B.
1979-01-01
Birth order effects in brothers were found to derive from difference in family size. Effects for family size were found even with socioeconomic background controlled. Nor were family size effects explained by parental ability. The importance of unmeasured preferences or economic resources that vary across families was suggested. (Author/RD)
Solid-state characterization of nevirapine.
Sarkar, Mahua; Perumal, O P; Panchagnula, R
2008-09-01
The purpose of this investigation is to characterize nevirapine from commercial samples and samples crystallized from different solvents under various conditions. The solid-state behavior of nevirapine samples was investigated using a variety of complementary techniques such as microscopy (optical, polarized, hot stage microscopy), differential scanning calorimeter, thermogravimetric analysis, Fourier transform infrared spectroscopy and powder X-ray diffractometry. The commercial samples of nevirapine had the same polymorphic crystalline form with an anhedral crystal habit. Intrinsic dissolution of nevirapine was similar for both the commercial batches. Powder dissolution showed pH dependency, with maximum dissolution in acidic pH and there was no significant effect of particle size. The samples recrystallized from different solvent systems with varying polarity yielded different crystal habits. Stirring and degrees of supersaturation influenced the size and shape of the crystals. The recrystallized samples did not produce any new polymorphic form, but weak solvates with varying crystal habit were produced. Recrystallized samples showed differences in the x-ray diffractograms. However, all the samples had the same internal crystal lattice as revealed from their similar melting points and heat of fusion. The intrinsic dissolution rate of recrystallized samples was lower than the commercial sample. It was found that the compression pressure resulted in desolvation and partial conversion of the crystal form. After compression, the recrystallized samples showed similar x-ray diffractograms to the commercial sample. Amorphous form showed slightly higher aqueous solubility than the commercial crystalline form.
Tay, Benjamin Chia-Meng; Chow, Tzu-Hao; Ng, Beng-Koon; Loh, Thomas Kwok-Seng
2012-09-01
This study investigates the autocorrelation bandwidths of dual-window (DW) optical coherence tomography (OCT) k-space scattering profile of different-sized microspheres and their correlation to scatterer size. A dual-bandwidth spectroscopic metric defined as the ratio of the 10% to 90% autocorrelation bandwidths is found to change monotonically with microsphere size and gives the best contrast enhancement for scatterer size differentiation in the resulting spectroscopic image. A simulation model supports the experimental results and revealed a tradeoff between the smallest detectable scatterer size and the maximum scatterer size in the linear range of the dual-window dual-bandwidth (DWDB) metric, which depends on the choice of the light source optical bandwidth. Spectroscopic OCT (SOCT) images of microspheres and tonsil tissue samples based on the proposed DWDB metric showed clear differentiation between different-sized scatterers as compared to those derived from conventional short-time Fourier transform metrics. The DWDB metric significantly improves the contrast in SOCT imaging and can aid the visualization and identification of dissimilar scatterer size in a sample. Potential applications include the early detection of cell nuclear changes in tissue carcinogenesis, the monitoring of healing tendons, and cell proliferation in tissue scaffolds.
Sediment laboratory quality-assurance project: studies of methods and materials
Gordon, J.D.; Newland, C.A.; Gray, J.R.
2001-01-01
In August 1996 the U.S. Geological Survey initiated the Sediment Laboratory Quality-Assurance project. The Sediment Laboratory Quality Assurance project is part of the National Sediment Laboratory Quality-Assurance program. This paper addresses the fmdings of the sand/fme separation analysis completed for the single-blind reference sediment-sample project and differences in reported results between two different analytical procedures. From the results it is evident that an incomplete separation of fme- and sand-size material commonly occurs resulting in the classification of some of the fme-size material as sand-size material. Electron microscopy analysis supported the hypothesis that the negative bias for fme-size material and the positive bias for sand-size material is largely due to aggregation of some of the fine-size material into sand-size particles and adherence of fine-size material to the sand-size grains. Electron microscopy analysis showed that preserved river water, which was low in dissolved solids, specific conductance, and neutral pH, showed less aggregation and adhesion than preserved river water that was higher in dissolved solids and specific conductance with a basic pH. Bacteria were also found growing in the matrix, which may enhance fme-size material aggregation through their adhesive properties. Differences between sediment-analysis methods were also investigated as pan of this study. Suspended-sediment concentration results obtained from one participating laboratory that used a total-suspended solids (TSS) method had greater variability and larger negative biases than results obtained when this laboratory used a suspended-sediment concentration method. When TSS methods were used to analyze the reference samples, the median suspended sediment concentration percent difference was -18.04 percent. When the laboratory used a suspended-sediment concentration method, the median suspended-sediment concentration percent difference was -2.74 percent. The percent difference was calculated as follows: Percent difference = (( reported mass - known mass)/known mass ) X 100.
Willan, Andrew R; Eckermann, Simon
2012-10-01
Previous applications of value of information methods for determining optimal sample size in randomized clinical trials have assumed no between-study variation in mean incremental net benefit. By adopting a hierarchical model, we provide a solution for determining optimal sample size with this assumption relaxed. The solution is illustrated with two examples from the literature. Expected net gain increases with increasing between-study variation, reflecting the increased uncertainty in incremental net benefit and reduced extent to which data are borrowed from previous evidence. Hence, a trial can become optimal where current evidence is sufficient assuming no between-study variation. However, despite the expected net gain increasing, the optimal sample size in the illustrated examples is relatively insensitive to the amount of between-study variation. Further percentage losses in expected net gain were small even when choosing sample sizes that reflected widely different between-study variation. Copyright © 2011 John Wiley & Sons, Ltd.
Thanh Noi, Phan; Kappas, Martin
2017-01-01
In previous classification studies, three non-parametric classifiers, Random Forest (RF), k-Nearest Neighbor (kNN), and Support Vector Machine (SVM), were reported as the foremost classifiers at producing high accuracies. However, only a few studies have compared the performances of these classifiers with different training sample sizes for the same remote sensing images, particularly the Sentinel-2 Multispectral Imager (MSI). In this study, we examined and compared the performances of the RF, kNN, and SVM classifiers for land use/cover classification using Sentinel-2 image data. An area of 30 × 30 km2 within the Red River Delta of Vietnam with six land use/cover types was classified using 14 different training sample sizes, including balanced and imbalanced, from 50 to over 1250 pixels/class. All classification results showed a high overall accuracy (OA) ranging from 90% to 95%. Among the three classifiers and 14 sub-datasets, SVM produced the highest OA with the least sensitivity to the training sample sizes, followed consecutively by RF and kNN. In relation to the sample size, all three classifiers showed a similar and high OA (over 93.85%) when the training sample size was large enough, i.e., greater than 750 pixels/class or representing an area of approximately 0.25% of the total study area. The high accuracy was achieved with both imbalanced and balanced datasets. PMID:29271909
Thanh Noi, Phan; Kappas, Martin
2017-12-22
In previous classification studies, three non-parametric classifiers, Random Forest (RF), k-Nearest Neighbor (kNN), and Support Vector Machine (SVM), were reported as the foremost classifiers at producing high accuracies. However, only a few studies have compared the performances of these classifiers with different training sample sizes for the same remote sensing images, particularly the Sentinel-2 Multispectral Imager (MSI). In this study, we examined and compared the performances of the RF, kNN, and SVM classifiers for land use/cover classification using Sentinel-2 image data. An area of 30 × 30 km² within the Red River Delta of Vietnam with six land use/cover types was classified using 14 different training sample sizes, including balanced and imbalanced, from 50 to over 1250 pixels/class. All classification results showed a high overall accuracy (OA) ranging from 90% to 95%. Among the three classifiers and 14 sub-datasets, SVM produced the highest OA with the least sensitivity to the training sample sizes, followed consecutively by RF and kNN. In relation to the sample size, all three classifiers showed a similar and high OA (over 93.85%) when the training sample size was large enough, i.e., greater than 750 pixels/class or representing an area of approximately 0.25% of the total study area. The high accuracy was achieved with both imbalanced and balanced datasets.
Temporal dynamics of linkage disequilibrium in two populations of bighorn sheep
Miller, Joshua M; Poissant, Jocelyn; Malenfant, René M; Hogg, John T; Coltman, David W
2015-01-01
Linkage disequilibrium (LD) is the nonrandom association of alleles at two markers. Patterns of LD have biological implications as well as practical ones when designing association studies or conservation programs aimed at identifying the genetic basis of fitness differences within and among populations. However, the temporal dynamics of LD in wild populations has received little empirical attention. In this study, we examined the overall extent of LD, the effect of sample size on the accuracy and precision of LD estimates, and the temporal dynamics of LD in two populations of bighorn sheep (Ovis canadensis) with different demographic histories. Using over 200 microsatellite loci, we assessed two metrics of multi-allelic LD, D′, and χ′2. We found that both populations exhibited high levels of LD, although the extent was much shorter in a native population than one that was founded via translocation, experienced a prolonged bottleneck post founding, followed by recent admixture. In addition, we observed significant variation in LD in relation to the sample size used, with small sample sizes leading to depressed estimates of the extent of LD but inflated estimates of background levels of LD. In contrast, there was not much variation in LD among yearly cross-sections within either population once sample size was accounted for. Lack of pronounced interannual variability suggests that researchers may not have to worry about interannual variation when estimating LD in a population and can instead focus on obtaining the largest sample size possible. PMID:26380673
Shiau, Yo-Jin; Chen, Jenn-Shing; Chung, Tay-Lung; Tian, Guanglong; Chiu, Chih-Yu
2017-12-01
Soil organic carbon (SOC) and carbon (C) functional groups in different particle-size fractions are important indicators of microbial activity and soil decomposition stages under wildfire disturbances. This research investigated a natural Tsuga forest and a nearby fire-induced grassland along a sampling transect in Central Taiwan with the aim to better understand the effect of forest wildfires on the change of SOC in different soil particle scales. Soil samples were separated into six particle sizes and SOC was characterized by solid-state 13 C nuclear magnetic resonance spectroscopy in each fraction. The SOC content was higher in forest than grassland soil in the particle-size fraction samples. The O-alkyl-C content (carbohydrate-derived structures) was higher in the grassland than the forest soils, but the alkyl-C content (recalcitrant substances) was higher in forest than grassland soils, for a higher humification degree (alkyl-C/O-alkyl-C ratio) in forest soils for all the soil particle-size fractions. High humification degree was found in forest soils. The similar aromaticity between forest and grassland soils might be attributed to the fire-induced aromatic-C content in the grassland that offsets the original difference between the forest and grassland. High alkyl-C content and humification degree and low C/N ratios in the fine particle-size fractions implied that undecomposed recalcitrant substances tended to accumulate in the fine fractions of soils.
Unequal cluster sizes in stepped-wedge cluster randomised trials: a systematic review.
Kristunas, Caroline; Morris, Tom; Gray, Laura
2017-11-15
To investigate the extent to which cluster sizes vary in stepped-wedge cluster randomised trials (SW-CRT) and whether any variability is accounted for during the sample size calculation and analysis of these trials. Any, not limited to healthcare settings. Any taking part in an SW-CRT published up to March 2016. The primary outcome is the variability in cluster sizes, measured by the coefficient of variation (CV) in cluster size. Secondary outcomes include the difference between the cluster sizes assumed during the sample size calculation and those observed during the trial, any reported variability in cluster sizes and whether the methods of sample size calculation and methods of analysis accounted for any variability in cluster sizes. Of the 101 included SW-CRTs, 48% mentioned that the included clusters were known to vary in size, yet only 13% of these accounted for this during the calculation of the sample size. However, 69% of the trials did use a method of analysis appropriate for when clusters vary in size. Full trial reports were available for 53 trials. The CV was calculated for 23 of these: the median CV was 0.41 (IQR: 0.22-0.52). Actual cluster sizes could be compared with those assumed during the sample size calculation for 14 (26%) of the trial reports; the cluster sizes were between 29% and 480% of that which had been assumed. Cluster sizes often vary in SW-CRTs. Reporting of SW-CRTs also remains suboptimal. The effect of unequal cluster sizes on the statistical power of SW-CRTs needs further exploration and methods appropriate to studies with unequal cluster sizes need to be employed. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
On sample size of the kruskal-wallis test with application to a mouse peritoneal cavity study.
Fan, Chunpeng; Zhang, Donghui; Zhang, Cun-Hui
2011-03-01
As the nonparametric generalization of the one-way analysis of variance model, the Kruskal-Wallis test applies when the goal is to test the difference between multiple samples and the underlying population distributions are nonnormal or unknown. Although the Kruskal-Wallis test has been widely used for data analysis, power and sample size methods for this test have been investigated to a much lesser extent. This article proposes new power and sample size calculation methods for the Kruskal-Wallis test based on the pilot study in either a completely nonparametric model or a semiparametric location model. No assumption is made on the shape of the underlying population distributions. Simulation results show that, in terms of sample size calculation for the Kruskal-Wallis test, the proposed methods are more reliable and preferable to some more traditional methods. A mouse peritoneal cavity study is used to demonstrate the application of the methods. © 2010, The International Biometric Society.
Measuring larval nematode contamination on cattle pastures: Comparing two herbage sampling methods.
Verschave, S H; Levecke, B; Duchateau, L; Vercruysse, J; Charlier, J
2015-06-15
Assessing levels of pasture larval contamination is frequently used to study the population dynamics of the free-living stages of parasitic nematodes of livestock. Direct quantification of infective larvae (L3) on herbage is the most applied method to measure pasture larval contamination. However, herbage collection remains labour intensive and there is a lack of studies addressing the variation induced by the sampling method and the required sample size. The aim of this study was (1) to compare two different sampling methods in terms of pasture larval count results and time required to sample, (2) to assess the amount of variation in larval counts at the level of sample plot, pasture and season, respectively and (3) to calculate the required sample size to assess pasture larval contamination with a predefined precision using random plots across pasture. Eight young stock pastures of different commercial dairy herds were sampled in three consecutive seasons during the grazing season (spring, summer and autumn). On each pasture, herbage samples were collected through both a double-crossed W-transect with samples taken every 10 steps (method 1) and four random located plots of 0.16 m(2) with collection of all herbage within the plot (method 2). The average (± standard deviation (SD)) pasture larval contamination using sampling methods 1 and 2 was 325 (± 479) and 305 (± 444)L3/kg dry herbage (DH), respectively. Large discrepancies in pasture larval counts of the same pasture and season were often seen between methods, but no significant difference (P = 0.38) in larval counts between methods was found. Less time was required to collect samples with method 2. This difference in collection time between methods was most pronounced for pastures with a surface area larger than 1 ha. The variation in pasture larval counts from samples generated by random plot sampling was mainly due to the repeated measurements on the same pasture in the same season (residual variance component = 6.2), rather than due to pasture (variance component = 0.55) or season (variance component = 0.15). Using the observed distribution of L3, the required sample size (i.e. number of plots per pasture) for sampling a pasture through random plots with a particular precision was simulated. A higher relative precision was acquired when estimating PLC on pastures with a high larval contamination and a low level of aggregation compared to pastures with a low larval contamination when the same sample size was applied. In the future, herbage sampling through random plots across pasture (method 2) seems a promising method to develop further as no significant difference in counts between the methods was found and this method was less time consuming. Copyright © 2015 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cappellari, Michele
2013-11-20
The distribution of galaxies on the mass-size plane as a function of redshift or environment is a powerful test for galaxy formation models. Here we use integral-field stellar kinematics to interpret the variation of the mass-size distribution in two galaxy samples spanning extreme environmental densities. The samples are both identically and nearly mass-selected (stellar mass M {sub *} ≳ 6 × 10{sup 9} M {sub ☉}) and volume-limited. The first consists of nearby field galaxies from the ATLAS{sup 3D} parent sample. The second consists of galaxies in the Coma Cluster (Abell 1656), one of the densest environments for which good, resolvedmore » spectroscopy can be obtained. The mass-size distribution in the dense environment differs from the field one in two ways: (1) spiral galaxies are replaced by bulge-dominated disk-like fast-rotator early-type galaxies (ETGs), which follow the same mass-size relation and have the same mass distribution as in the field sample; (2) the slow-rotator ETGs are segregated in mass from the fast rotators, with their size increasing proportionally to their mass. A transition between the two processes appears around the stellar mass M {sub crit} ≈ 2 × 10{sup 11} M {sub ☉}. We interpret this as evidence for bulge growth (outside-in evolution) and bulge-related environmental quenching dominating at low masses, with little influence from merging. In contrast, significant dry mergers (inside-out evolution) and halo-related quenching drives the mass and size growth at the high-mass end. The existence of these two processes naturally explains the diverse size evolution of galaxies of different masses and the separability of mass and environmental quenching.« less
Liu, Shuxin; Wang, Haibin; Yin, Hengbo; Wang, Hong; He, Jichuan
2014-03-01
The carbon coated LiFePO4 (LiFePO4/C) nanocomposites materials were successfully synthesized by sol-gel method. The microstructure and morphology of LiFePO4/C nanocomposites were characterized by X-ray diffraction, Raman spectroscopy and scanning electron microscopy. The results showed that the carbon layers decomposed by different dispersant and carbon source had different graphitization degree, and the sugar could decompose to form more graphite-like structure carbon. The carbon source and heat-treatment temperature had some effect on the particle size and morphology, the sample LFP-S700 synthesized by adding sugar as carbon source at 700 degrees C had smaller particle size, uniform size distribution and spherical shape. The electrochemical behavior of LiFePO4/C nanocomposites was analyzed using galvanostatic measurements and cyclic voltammetry (CV). The results showed that the sample LFP-S700 had higher discharge specific capacities, higher apparent lithium ion diffusion coefficient and lower charge transfer resistance. The excellent electrochemical performance of sample LFP-S700 could be attributed to its high graphitization degree of carbon, smaller particle size and uniform size distribution.
Vercellotti, Giuseppe; Stout, Sam D; Boano, Rosa; Sciulli, Paul W
2011-06-01
The phenotypic expression of adult body size and shape results from synergistic interactions between hereditary factors and environmental conditions experienced during growth. Variation in body size and shape occurs even in genetically relatively homogeneous groups, due to different occurrence, duration, and timing of growth insults. Understanding the causes and patterns of intrapopulation variation can foster meaningful information on early life conditions in living and past populations. This study assesses the pattern of biological variation in body size and shape attributable to sex and social status in a medieval Italian population. The sample includes 52 (20 female, 32 male) adult individuals from the medieval population of Trino Vercellese, Italy. Differences in element size and overall body size (skeletal height and body mass) were assessed through Monte Carlo methods, while univariate non-parametric tests and Principal Component Analysis (PCA) were employed to examine segmental and overall body proportions. Discriminant Analysis was employed to determine the predictive value of individual skeletal elements for social status in the population. Our results highlight a distinct pattern in body size and shape variation in relation to status and sex. Male subsamples exhibit significant postcranial variation in body size, while female subsamples express smaller, nonsignificant differences. The analysis of segmental proportions highlighted differences in trunk/lower limb proportions between different status samples, and PCA indicated that in terms of purely morphological variation high status males were distinct from all other groups. The pattern observed likely resulted from a combination of biological factors and cultural practices. Copyright © 2011 Wiley-Liss, Inc.
Cho, Seung-Hyun; Tong, Haiyan; McGee, John K.; Baldauf, Richard W.; Krantz, Q. Todd; Gilmour, M. Ian
2009-01-01
Background Epidemiologic studies have reported an association between proximity to highway traffic and increased cardiopulmonary illnesses. Objectives We investigated the effect of size-fractionated particulate matter (PM), obtained at different distances from a highway, on acute cardiopulmonary toxicity in mice. Methods We collected PM for 2 weeks in July–August 2006 using a three-stage (ultrafine, < 0.1 μm; fine, 0.1–2.5 μm; coarse, 2.5–10 μm) high-volume impactor at distances of 20 m [near road (NR)] and 275 m [far road (FR)] from an interstate highway in Raleigh, North Carolina. Samples were extracted in methanol, dried, diluted in saline, and then analyzed for chemical constituents. Female CD-1 mice received either 25 or 100 μg of each size fraction via oropharyngeal aspiration. At 4 and 18 hr postexposure, mice were assessed for pulmonary responsiveness to inhaled methacholine, biomarkers of lung injury and inflammation; ex vivo cardiac pathophysiology was assessed at 18 hr only. Results Overall chemical composition between NR and FR PM was similar, although NR samples comprised larger amounts of PM, endotoxin, and certain metals than did the FR samples. Each PM size fraction showed differences in ratios of major chemical classes. Both NR and FR coarse PM produced significant pulmonary inflammation irrespective of distance, whereas both NR and FR ultrafine PM induced cardiac ischemia–reperfusion injury. Conclusions On a comparative mass basis, the coarse and ultrafine PM affected the lung and heart, respectively. We observed no significant differences in the overall toxicity end points and chemical makeup between the NR and FR PM. The results suggest that PM of different size-specific chemistry might be associated with different toxicologic mechanisms in cardiac and pulmonary tissues. PMID:20049117
Li, Yiwen; Shen, Yang; Pi, Lu; Hu, Wenli; Chen, Mengqin; Luo, Yan; Li, Zhi; Su, Shijun; Ding, Sanglan; Gan, Zhiwei
2016-01-01
A total of 27 settled dust samples were collected from urban roads, parks, and roofs in Chengdu, China to investigate particle size distribution and perchlorate levels in different size fractions. Briefly, fine particle size fractions (<250 μm) were the dominant composition in the settled dust samples, with mean percentages of 80.2%, 69.5%, and 77.2% for the urban roads, roofs, and the parks, respectively. Perchlorate was detected in all of the size-fractionated dust samples, with concentrations ranging from 73.0 to 6160 ng g(-1), and the median perchlorate levels increased with decreasing particle size. The perchlorate level in the finest fraction (<63 μm) was significantly higher than those in the coarser fractions. To our knowledge, this is the first report on perchlorate concentrations in different particle size fractions. The calculated perchlorate loadings revealed that perchlorate was mainly associated with finer particles (<125 μm). An exposure assessment indicated that exposure to perchlorate via settled road dust intake is safe to both children and adults in Chengdu, China. However, due to perchlorate mainly existing in fine particles, there is a potential for perchlorate to transfer into surface water and the atmosphere by runoff and wind erosion or traffic emission, and this could act as an important perchlorate pollution source for the indoor environment, and merits further study.
The impact of multiple endpoint dependency on Q and I(2) in meta-analysis.
Thompson, Christopher Glen; Becker, Betsy Jane
2014-09-01
A common assumption in meta-analysis is that effect sizes are independent. When correlated effect sizes are analyzed using traditional univariate techniques, this assumption is violated. This research assesses the impact of dependence arising from treatment-control studies with multiple endpoints on homogeneity measures Q and I(2) in scenarios using the unbiased standardized-mean-difference effect size. Univariate and multivariate meta-analysis methods are examined. Conditions included different overall outcome effects, study sample sizes, numbers of studies, between-outcomes correlations, dependency structures, and ways of computing the correlation. The univariate approach used typical fixed-effects analyses whereas the multivariate approach used generalized least-squares (GLS) estimates of a fixed-effects model, weighted by the inverse variance-covariance matrix. Increased dependence among effect sizes led to increased Type I error rates from univariate models. When effect sizes were strongly dependent, error rates were drastically higher than nominal levels regardless of study sample size and number of studies. In contrast, using GLS estimation to account for multiple-endpoint dependency maintained error rates within nominal levels. Conversely, mean I(2) values were not greatly affected by increased amounts of dependency. Last, we point out that the between-outcomes correlation should be estimated as a pooled within-groups correlation rather than using a full-sample estimator that does not consider treatment/control group membership. Copyright © 2014 John Wiley & Sons, Ltd.
Foundational Principles for Large-Scale Inference: Illustrations Through Correlation Mining.
Hero, Alfred O; Rajaratnam, Bala
2016-01-01
When can reliable inference be drawn in fue "Big Data" context? This paper presents a framework for answering this fundamental question in the context of correlation mining, wifu implications for general large scale inference. In large scale data applications like genomics, connectomics, and eco-informatics fue dataset is often variable-rich but sample-starved: a regime where the number n of acquired samples (statistical replicates) is far fewer than fue number p of observed variables (genes, neurons, voxels, or chemical constituents). Much of recent work has focused on understanding the computational complexity of proposed methods for "Big Data". Sample complexity however has received relatively less attention, especially in the setting when the sample size n is fixed, and the dimension p grows without bound. To address fuis gap, we develop a unified statistical framework that explicitly quantifies the sample complexity of various inferential tasks. Sampling regimes can be divided into several categories: 1) the classical asymptotic regime where fue variable dimension is fixed and fue sample size goes to infinity; 2) the mixed asymptotic regime where both variable dimension and sample size go to infinity at comparable rates; 3) the purely high dimensional asymptotic regime where the variable dimension goes to infinity and the sample size is fixed. Each regime has its niche but only the latter regime applies to exa cale data dimension. We illustrate this high dimensional framework for the problem of correlation mining, where it is the matrix of pairwise and partial correlations among the variables fua t are of interest. Correlation mining arises in numerous applications and subsumes the regression context as a special case. we demonstrate various regimes of correlation mining based on the unifying perspective of high dimensional learning rates and sample complexity for different structured covariance models and different inference tasks.
Overlap between treatment and control distributions as an effect size measure in experiments.
Hedges, Larry V; Olkin, Ingram
2016-03-01
The proportion π of treatment group observations that exceed the control group mean has been proposed as an effect size measure for experiments that randomly assign independent units into 2 groups. We give the exact distribution of a simple estimator of π based on the standardized mean difference and use it to study the small sample bias of this estimator. We also give the minimum variance unbiased estimator of π under 2 models, one in which the variance of the mean difference is known and one in which the variance is unknown. We show how to use the relation between the standardized mean difference and the overlap measure to compute confidence intervals for π and show that these results can be used to obtain unbiased estimators, large sample variances, and confidence intervals for 3 related effect size measures based on the overlap. Finally, we show how the effect size π can be used in a meta-analysis. (c) 2016 APA, all rights reserved).
[A comparison of convenience sampling and purposive sampling].
Suen, Lee-Jen Wu; Huang, Hui-Man; Lee, Hao-Hsien
2014-06-01
Convenience sampling and purposive sampling are two different sampling methods. This article first explains sampling terms such as target population, accessible population, simple random sampling, intended sample, actual sample, and statistical power analysis. These terms are then used to explain the difference between "convenience sampling" and purposive sampling." Convenience sampling is a non-probabilistic sampling technique applicable to qualitative or quantitative studies, although it is most frequently used in quantitative studies. In convenience samples, subjects more readily accessible to the researcher are more likely to be included. Thus, in quantitative studies, opportunity to participate is not equal for all qualified individuals in the target population and study results are not necessarily generalizable to this population. As in all quantitative studies, increasing the sample size increases the statistical power of the convenience sample. In contrast, purposive sampling is typically used in qualitative studies. Researchers who use this technique carefully select subjects based on study purpose with the expectation that each participant will provide unique and rich information of value to the study. As a result, members of the accessible population are not interchangeable and sample size is determined by data saturation not by statistical power analysis.
Shah, R; Worner, S P; Chapman, R B
2012-10-01
Pesticide resistance monitoring includes resistance detection and subsequent documentation/ measurement. Resistance detection would require at least one (≥1) resistant individual(s) to be present in a sample to initiate management strategies. Resistance documentation, on the other hand, would attempt to get an estimate of the entire population (≥90%) of the resistant individuals. A computer simulation model was used to compare the efficiency of simple random and systematic sampling plans to detect resistant individuals and to document their frequencies when the resistant individuals were randomly or patchily distributed. A patchy dispersion pattern of resistant individuals influenced the sampling efficiency of systematic sampling plans while the efficiency of random sampling was independent of such patchiness. When resistant individuals were randomly distributed, sample sizes required to detect at least one resistant individual (resistance detection) with a probability of 0.95 were 300 (1%) and 50 (10% and 20%); whereas, when resistant individuals were patchily distributed, using systematic sampling, sample sizes required for such detection were 6000 (1%), 600 (10%) and 300 (20%). Sample sizes of 900 and 400 would be required to detect ≥90% of resistant individuals (resistance documentation) with a probability of 0.95 when resistant individuals were randomly dispersed and present at a frequency of 10% and 20%, respectively; whereas, when resistant individuals were patchily distributed, using systematic sampling, a sample size of 3000 and 1500, respectively, was necessary. Small sample sizes either underestimated or overestimated the resistance frequency. A simple random sampling plan is, therefore, recommended for insecticide resistance detection and subsequent documentation.
The distance between Mars and Venus: measuring global sex differences in personality.
Del Giudice, Marco; Booth, Tom; Irwing, Paul
2012-01-01
Sex differences in personality are believed to be comparatively small. However, research in this area has suffered from significant methodological limitations. We advance a set of guidelines for overcoming those limitations: (a) measure personality with a higher resolution than that afforded by the Big Five; (b) estimate sex differences on latent factors; and (c) assess global sex differences with multivariate effect sizes. We then apply these guidelines to a large, representative adult sample, and obtain what is presently the best estimate of global sex differences in personality. Personality measures were obtained from a large US sample (N = 10,261) with the 16PF Questionnaire. Multigroup latent variable modeling was used to estimate sex differences on individual personality dimensions, which were then aggregated to yield a multivariate effect size (Mahalanobis D). We found a global effect size D = 2.71, corresponding to an overlap of only 10% between the male and female distributions. Even excluding the factor showing the largest univariate ES, the global effect size was D = 1.71 (24% overlap). These are extremely large differences by psychological standards. The idea that there are only minor differences between the personality profiles of males and females should be rejected as based on inadequate methodology.
The Distance Between Mars and Venus: Measuring Global Sex Differences in Personality
Del Giudice, Marco; Booth, Tom; Irwing, Paul
2012-01-01
Background Sex differences in personality are believed to be comparatively small. However, research in this area has suffered from significant methodological limitations. We advance a set of guidelines for overcoming those limitations: (a) measure personality with a higher resolution than that afforded by the Big Five; (b) estimate sex differences on latent factors; and (c) assess global sex differences with multivariate effect sizes. We then apply these guidelines to a large, representative adult sample, and obtain what is presently the best estimate of global sex differences in personality. Methodology/Principal Findings Personality measures were obtained from a large US sample (N = 10,261) with the 16PF Questionnaire. Multigroup latent variable modeling was used to estimate sex differences on individual personality dimensions, which were then aggregated to yield a multivariate effect size (Mahalanobis D). We found a global effect size D = 2.71, corresponding to an overlap of only 10% between the male and female distributions. Even excluding the factor showing the largest univariate ES, the global effect size was D = 1.71 (24% overlap). These are extremely large differences by psychological standards. Significance The idea that there are only minor differences between the personality profiles of males and females should be rejected as based on inadequate methodology. PMID:22238596
A Comparison of Learning Cultures in Different Sizes and Types
ERIC Educational Resources Information Center
Brown, Paula D.; Finch, Kim S.; MacGregor, Cynthia
2012-01-01
This study compared relevant data and information about leadership and learning cultures in different sizes and types of high schools. Research was conducted using a quantitative design with a qualitative element. Quantitative data were gathered using a researcher-created survey. Independent sample t-tests were conducted to analyze the means of…
Jannink, I; Bennen, J N; Blaauw, J; van Diest, P J; Baak, J P
1995-01-01
This study compares the influence of two different nuclear sampling methods on the prognostic value of assessments of mean and standard deviation of nuclear area (MNA, SDNA) in 191 consecutive invasive breast cancer patients with long term follow up. The first sampling method used was 'at convenience' sampling (ACS); the second, systematic random sampling (SRS). Both sampling methods were tested with a sample size of 50 nuclei (ACS-50 and SRS-50). To determine whether, besides the sampling methods, sample size had impact on prognostic value as well, the SRS method was also tested using a sample size of 100 nuclei (SRS-100). SDNA values were systematically lower for ACS, obviously due to (unconsciously) not including small and large nuclei. Testing prognostic value of a series of cut off points, MNA and SDNA values assessed by the SRS method were prognostically significantly stronger than the values obtained by the ACS method. This was confirmed in Cox regression analysis. For the MNA, the Mantel-Cox p-values from SRS-50 and SRS-100 measurements were not significantly different. However, for the SDNA, SRS-100 yielded significantly lower p-values than SRS-50. In conclusion, compared with the 'at convenience' nuclear sampling method, systematic random sampling of nuclei is not only superior with respect to reproducibility of results, but also provides a better prognostic value in patients with invasive breast cancer.
Baldissera, Sandro; Ferrante, Gianluigi; Quarchioni, Elisa; Minardi, Valentina; Possenti, Valentina; Carrozzi, Giuliano; Masocco, Maria; Salmaso, Stefania
2014-04-01
Field substitution of nonrespondents can be used to maintain the planned sample size and structure in surveys but may introduce additional bias. Sample weighting is suggested as the preferable alternative; however, limited empirical evidence exists comparing the two methods. We wanted to assess the impact of substitution on surveillance results using data from Progressi delle Aziende Sanitarie per la Salute in Italia-Progress by Local Health Units towards a Healthier Italy (PASSI). PASSI is conducted by Local Health Units (LHUs) through telephone interviews of stratified random samples of residents. Nonrespondents are replaced with substitutes randomly preselected in the same LHU stratum. We compared the weighted estimates obtained in the original PASSI sample (used as a reference) and in the substitutes' sample. The differences were evaluated using a Wald test. In 2011, 50,697 units were selected: 37,252 were from the original sample and 13,445 were substitutes; 37,162 persons were interviewed. The initially planned size and demographic composition were restored. No significant differences in the estimates between the original and the substitutes' sample were found. In our experience, field substitution is an acceptable method for dealing with nonresponse, maintaining the characteristics of the original sample without affecting the results. This evidence can support appropriate decisions about planning and implementing a surveillance system. Copyright © 2014 Elsevier Inc. All rights reserved.
Yoshida, Sachiyo; Rudan, Igor; Cousens, Simon
2016-01-01
Introduction Crowdsourcing has become an increasingly important tool to address many problems – from government elections in democracies, stock market prices, to modern online tools such as TripAdvisor or Internet Movie Database (IMDB). The CHNRI method (the acronym for the Child Health and Nutrition Research Initiative) for setting health research priorities has crowdsourcing as the major component, which it uses to generate, assess and prioritize between many competing health research ideas. Methods We conducted a series of analyses using data from a group of 91 scorers to explore the quantitative properties of their collective opinion. We were interested in the stability of their collective opinion as the sample size increases from 15 to 90. From a pool of 91 scorers who took part in a previous CHNRI exercise, we used sampling with replacement to generate multiple random samples of different size. First, for each sample generated, we identified the top 20 ranked research ideas, among 205 that were proposed and scored, and calculated the concordance with the ranking generated by the 91 original scorers. Second, we used rank correlation coefficients to compare the ranks assigned to all 205 proposed research ideas when samples of different size are used. We also analysed the original pool of 91 scorers to to look for evidence of scoring variations based on scorers' characteristics. Results The sample sizes investigated ranged from 15 to 90. The concordance for the top 20 scored research ideas increased with sample sizes up to about 55 experts. At this point, the median level of concordance stabilized at 15/20 top ranked questions (75%), with the interquartile range also generally stable (14–16). There was little further increase in overlap when the sample size increased from 55 to 90. When analysing the ranking of all 205 ideas, the rank correlation coefficient increased as the sample size increased, with a median correlation of 0.95 reached at the sample size of 45 experts (median of the rank correlation coefficient = 0.95; IQR 0.94–0.96). Conclusions Our analyses suggest that the collective opinion of an expert group on a large number of research ideas, expressed through categorical variables (Yes/No/Not Sure/Don't know), stabilises relatively quickly in terms of identifying the ideas that have most support. In the exercise we found a high degree of reproducibility of the identified research priorities was achieved with as few as 45–55 experts. PMID:27350874
Yoshida, Sachiyo; Rudan, Igor; Cousens, Simon
2016-06-01
Crowdsourcing has become an increasingly important tool to address many problems - from government elections in democracies, stock market prices, to modern online tools such as TripAdvisor or Internet Movie Database (IMDB). The CHNRI method (the acronym for the Child Health and Nutrition Research Initiative) for setting health research priorities has crowdsourcing as the major component, which it uses to generate, assess and prioritize between many competing health research ideas. We conducted a series of analyses using data from a group of 91 scorers to explore the quantitative properties of their collective opinion. We were interested in the stability of their collective opinion as the sample size increases from 15 to 90. From a pool of 91 scorers who took part in a previous CHNRI exercise, we used sampling with replacement to generate multiple random samples of different size. First, for each sample generated, we identified the top 20 ranked research ideas, among 205 that were proposed and scored, and calculated the concordance with the ranking generated by the 91 original scorers. Second, we used rank correlation coefficients to compare the ranks assigned to all 205 proposed research ideas when samples of different size are used. We also analysed the original pool of 91 scorers to to look for evidence of scoring variations based on scorers' characteristics. The sample sizes investigated ranged from 15 to 90. The concordance for the top 20 scored research ideas increased with sample sizes up to about 55 experts. At this point, the median level of concordance stabilized at 15/20 top ranked questions (75%), with the interquartile range also generally stable (14-16). There was little further increase in overlap when the sample size increased from 55 to 90. When analysing the ranking of all 205 ideas, the rank correlation coefficient increased as the sample size increased, with a median correlation of 0.95 reached at the sample size of 45 experts (median of the rank correlation coefficient = 0.95; IQR 0.94-0.96). Our analyses suggest that the collective opinion of an expert group on a large number of research ideas, expressed through categorical variables (Yes/No/Not Sure/Don't know), stabilises relatively quickly in terms of identifying the ideas that have most support. In the exercise we found a high degree of reproducibility of the identified research priorities was achieved with as few as 45-55 experts.
Variations in the moisture content of several fuel size components of live and dead chamise
John D. Dell; Charles W. Philpot
1965-01-01
Samples taken May 25, Sept. 2, and Dec. 8, 1964, indicated that leaves were the only fuel components of live chamise with appreciable seasonal moisture fluctuation. A close relationship in fuel moistures existed between like components from the different shrubs sampled. Dead chamise showed little or no variation due to fuel size or season of the year.
ERIC Educational Resources Information Center
Seo, Dong Gi; Hao, Shiqi
2016-01-01
Differential item/test functioning (DIF/DTF) are routine procedures to detect item/test unfairness as an explanation for group performance difference. However, unequal sample sizes and small sample sizes have an impact on the statistical power of the DIF/DTF detection procedures. Furthermore, DIF/DTF cannot be used for two test forms without…
NASA Astrophysics Data System (ADS)
Guerrero, C.; Zornoza, R.; Gómez, I.; Mataix-Solera, J.; Navarro-Pedreño, J.; Mataix-Beneyto, J.; García-Orenes, F.
2009-04-01
Near infrared (NIR) reflectance spectroscopy offers important advantages because is a non-destructive technique, the pre-treatments needed in samples are minimal, and the spectrum of the sample is obtained in less than 1 minute without the needs of chemical reagents. For these reasons, NIR is a fast and cost-effective method. Moreover, NIR allows the analysis of several constituents or parameters simultaneously from the same spectrum once it is obtained. For this, a needed steep is the development of soil spectral libraries (set of samples analysed and scanned) and calibrations (using multivariate techniques). The calibrations should contain the variability of the target site soils in which the calibration is to be used. Many times this premise is not easy to fulfil, especially in libraries recently developed. A classical way to solve this problem is through the repopulation of libraries and the subsequent recalibration of the models. In this work we studied the changes in the accuracy of the predictions as a consequence of the successive addition of samples to repopulation. In general, calibrations with high number of samples and high diversity are desired. But we hypothesized that calibrations with lower quantities of samples (lower size) will absorb more easily the spectral characteristics of the target site. Thus, we suspect that the size of the calibration (model) that will be repopulated could be important. For this reason we also studied this effect in the accuracy of predictions of the repopulated models. In this study we used those spectra of our library which contained data of soil Kjeldahl Nitrogen (NKj) content (near to 1500 samples). First, those spectra from the target site were removed from the spectral library. Then, different quantities of samples of the library were selected (representing the 5, 10, 25, 50, 75 and 100% of the total library). These samples were used to develop calibrations with different sizes (%) of samples. We used partial least squares regression, and leave-one-out cross validation as methods of calibration. Two methods were used to select the different quantities (size of models) of samples: (1) Based on Characteristics of Spectra (BCS), and (2) Based on NKj Values of Samples (BVS). Both methods tried to select representative samples. Each of the calibrations (containing the 5, 10, 25, 50, 75 or 100% of the total samples of the library) was repopulated with samples from the target site and then recalibrated (by leave-one-out cross validation). This procedure was sequential. In each step, 2 samples from the target site were added to the models, and then recalibrated. This process was repeated successively 10 times, being 20 the total number of samples added. A local model was also created with the 20 samples used for repopulation. The repopulated, non-repopulated and local calibrations were used to predict the NKj content in those samples from the target site not included in repopulations. For the measurement of the accuracy of the predictions, the r2, RMSEP and slopes were calculated comparing predicted with analysed NKj values. This scheme was repeated for each of the four target sites studied. In general, scarce differences can be found between results obtained with BCS and BVS models. We observed that the repopulation of models increased the r2 of the predictions in sites 1 and 3. The repopulation caused scarce changes of the r2 of the predictions in sites 2 and 4, maybe due to the high initial values (using non-repopulated models r2 >0.90). As consequence of repopulation, the RMSEP decreased in all the sites except in site 2, where a very low RMESP was obtained before the repopulation (0.4 g×kg-1). The slopes trended to approximate to 1, but this value was reached only in site 4 and after the repopulation with 20 samples. In sites 3 and 4, accurate predictions were obtained using the local models. Predictions obtained with models using similar size of samples (similar %) were averaged with the aim to describe the main patterns. The r2 of predictions obtained with models of higher size were not more accurate than those obtained with models of lower size. After repopulation, the RMSEP of predictions using models with lower sizes (5, 10 and 25% of samples of the library) were lower than RMSEP obtained with higher sizes (75 and 100%), indicating that small models can easily integrate the variability of the soils from the target site. The results suggest that calibrations of small size could be repopulated and "converted" in local calibrations. According to this, we can focus most of the efforts in the obtainment of highly accurate analytical values in a reduced set of samples (including some samples from the target sites). The patterns observed here are in opposition with the idea of global models. These results could encourage the expansion of this technique, because very large data based seems not to be needed. Future studies with very different samples will help to confirm the robustness of the patterns observed. Authors acknowledge to "Bancaja-UMH" for the financial support of the project "NIRPROS".
Johnson, K E; McMorris, B J; Raynor, L A; Monsen, K A
2013-01-01
The Omaha System is a standardized interface terminology that is used extensively by public health nurses in community settings to document interventions and client outcomes. Researchers using Omaha System data to analyze the effectiveness of interventions have typically calculated p-values to determine whether significant client changes occurred between admission and discharge. However, p-values are highly dependent on sample size, making it difficult to distinguish statistically significant changes from clinically meaningful changes. Effect sizes can help identify practical differences but have not yet been applied to Omaha System data. We compared p-values and effect sizes (Cohen's d) for mean differences between admission and discharge for 13 client problems documented in the electronic health records of 1,016 young low-income parents. Client problems were documented anywhere from 6 (Health Care Supervision) to 906 (Caretaking/parenting) times. On a scale from 1 to 5, the mean change needed to yield a large effect size (Cohen's d ≥ 0.80) was approximately 0.60 (range = 0.50 - 1.03) regardless of p-value or sample size (i.e., the number of times a client problem was documented in the electronic health record). Researchers using the Omaha System should report effect sizes to help readers determine which differences are practical and meaningful. Such disclosures will allow for increased recognition of effective interventions.
NASA Technical Reports Server (NTRS)
Parada, N. D. J. (Principal Investigator); Moreira, M. A.; Chen, S. C.; Batista, G. T.
1984-01-01
A procedure to estimate wheat (Triticum aestivum L) area using sampling technique based on aerial photographs and digital LANDSAT MSS data is developed. Aerial photographs covering 720 square km are visually analyzed. To estimate wheat area, a regression approach is applied using different sample sizes and various sampling units. As the size of sampling unit decreased, the percentage of sampled area required to obtain similar estimation performance also decreased. The lowest percentage of the area sampled for wheat estimation with relatively high precision and accuracy through regression estimation is 13.90% using 10 square km as the sampling unit. Wheat area estimation using only aerial photographs is less precise and accurate than those obtained by regression estimation.
An Analysis of Methods Used to Examine Gender Differences in Computer-Related Behavior.
ERIC Educational Resources Information Center
Kay, Robin
1992-01-01
Review of research investigating gender differences in computer-related behavior examines statistical and methodological flaws. Issues addressed include sample selection, sample size, scale development, scale quality, the use of univariate and multivariate analyses, regressional analysis, construct definition, construct testing, and the…
Woodman, N.; Croft, D.A.
2005-01-01
Our study of mammalian remains excavated in the 1940s from McGrew Cave, north of Copan, Honduras, yielded an assemblage of 29 taxa that probably accumulated predominantly as the result of predation by owls. Among the taxa present are three species of small-eared shrews, genus Cryptotis. One species, Cryptotis merriami, is relatively rare among the fossil remains. The other two shrews, Cryptotis goodwini and Cryptotis orophila, are abundant and exhibit morpho metrical variation distinguishing them from modern populations. Fossils of C. goodwini are distinctly and consistently smaller than modern members of the species. To quantify the size differences, we derived common measures of body size for fossil C. goodwini using regression models based on modern samples of shrews in the Cryptotis mexicana-group. Estimated mean length of head and body for the fossil sample is 72-79 mm, and estimated mean mass is 7.6-9.6 g. These numbers indicate that the fossil sample averaged 6-14% smaller in head and body length and 39-52% less in mass than the modern sample and that increases of 6-17% in head and body length and 65-108% in mass occurred to achieve the mean body size of the modern sample. Conservative estimates of fresh (wet) food intake based on mass indicate that such a size increase would require a 37-58% increase in daily food consumption. In contrast to C. goodwini, fossil C. orophila from the cave is not different in mean body size from modern samples. The fossil sample does, however, show slightly greater variation in size than is currently present throughout the modern geographical distribution of the taxon. Moreover, variation in some other dental and mandibular characters is more constrained, exhibiting a more direct relationship to overall size. Our study of these species indicates that North American shrews have not all been static in size through time, as suggested by some previous work with fossil soricids. Lack of stratigraphic control within the site and our failure to obtain reliable radiometric dates on remains restrict our opportunities to place the site in a firm temporal context. However, the morphometrical differences we document for fossil C. orophila and C. goodwini show them to be distinct from modern populations of these shrews. Some other species of fossil mammals from McGrew Cave exhibit distinct size changes of the magnitudes experienced by many northern North American and some Mexican mammals during the transition from late glacial to Holocene environmental conditions, and it is likely that at least some of the remains from the cave are late Pleistocene in age. One curious factor is that, whereas most mainland mammals that exhibit large-scale size shifts during the late glacial/postglacial transition experienced dwarfing, C. goodwini increased in size. The lack of clinal variation in modern C. goodwini supports the hypothesis that size evolution can result from local selection rather than from cline translocation. Models of size change in mammals indicate that increased size, such as that observed for C. goodwini, are a likely consequence of increased availability of resources and, thereby, a relaxation of selection during critical times of the year.
Catch me if you can: Comparing ballast water sampling skids to traditional net sampling
NASA Astrophysics Data System (ADS)
Bradie, Johanna; Gianoli, Claudio; Linley, Robert Dallas; Schillak, Lothar; Schneider, Gerd; Stehouwer, Peter; Bailey, Sarah
2018-03-01
With the recent ratification of the International Convention for the Control and Management of Ships' Ballast Water and Sediments, 2004, it will soon be necessary to assess ships for compliance with ballast water discharge standards. Sampling skids that allow the efficient collection of ballast water samples in a compact space have been developed for this purpose. We ran 22 trials on board the RV Meteor from June 4-15, 2015 to evaluate the performance of three ballast water sampling devices (traditional plankton net, Triton sampling skid, SGS sampling skid) for three organism size classes: ≥ 50 μm, ≥ 10 μm to < 50 μm, and < 10 μm. Natural sea water was run through the ballast water system and untreated samples were collected using paired sampling devices. Collected samples were analyzed in parallel by multiple analysts using several different analytic methods to quantify organism concentrations. To determine whether there were differences in the number of viable organisms collected across sampling devices, results were standardized and statistically treated to filter out other sources of variability, resulting in an outcome variable representing the mean difference in measurements that can be attributed to sampling devices. These results were tested for significance using pairwise Tukey contrasts. Differences in organism concentrations were found in 50% of comparisons between sampling skids and the plankton net for ≥ 50 μm, and ≥ 10 μm to < 50 μm size classes, with net samples containing either higher or lower densities. There were no differences for < 10 μm organisms. Future work will be required to explicitly examine the potential effects of flow velocity, sampling duration, sampled volume, and organism concentrations on sampling device performance.
Considerations for throughfall chemistry sample-size determination
Pamela J. Edwards; Paul Mohai; Howard G. Halverson; David R. DeWalle
1989-01-01
Both the number of trees sampled per species and the number of sampling points under each tree are important throughfall sampling considerations. Chemical loadings obtained from an urban throughfall study were used to evaluate the relative importance of both of these sampling factors in tests for determining species' differences. Power curves for detecting...
Evaluation of residual uranium contamination in the dirt floor of an abandoned metal rolling mill.
Glassford, Eric; Spitz, Henry; Lobaugh, Megan; Spitler, Grant; Succop, Paul; Rice, Carol
2013-02-01
A single, large, bulk sample of uranium-contaminated material from the dirt floor of an abandoned metal rolling mill was separated into different types and sizes of aliquots to simulate samples that would be collected during site remediation. The facility rolled approximately 11,000 tons of hot-forged ingots of uranium metal approximately 60 y ago, and it has not been used since that time. Thirty small mass (≈ 0.7 g) and 15 large mass (≈ 70 g) samples were prepared from the heterogeneously contaminated bulk material to determine how measurements of the uranium contamination vary with sample size. Aliquots of bulk material were also resuspended in an exposure chamber to produce six samples of respirable particles that were obtained using a cascade impactor. Samples of removable surface contamination were collected by wiping 100 cm of the interior surfaces of the exposure chamber with 47-mm-diameter fiber filters. Uranium contamination in each of the samples was measured directly using high-resolution gamma ray spectrometry. As expected, results for isotopic uranium (i.e., U and U) measured with the large-mass and small-mass samples are significantly different (p < 0.001), and the coefficient of variation (COV) for the small-mass samples was greater than for the large-mass samples. The uranium isotopic concentrations measured in the air and on the wipe samples were not significantly different and were also not significantly different (p > 0.05) from results for the large- or small-mass samples. Large-mass samples are more reliable for characterizing heterogeneously distributed radiological contamination than small-mass samples since they exhibit the least variation compared to the mean. Thus, samples should be sufficiently large in mass to insure that the results are truly representative of the heterogeneously distributed uranium contamination present at the facility. Monitoring exposure of workers and the public as a result of uranium contamination resuspended during site remediation should be evaluated using samples of sufficient size and type to accommodate the heterogeneous distribution of uranium in the bulk material.
Hydrochemical responses among nested catchments of the Sleepers River Research Watershed.
NASA Astrophysics Data System (ADS)
Sebestyen, S. D.; Boyer, E. W.; Shanley, J. B.; Kendall, C.
2005-12-01
We are probing chemical and isotopic tracers of dissolved organic carbon (DOC) and nitrate over both space and time to determine how stream nutrient dynamics change with increasing basin size and differ with flow conditions. At the Sleepers River Research Watershed in northeastern Vermont, USA, 20 to 30 nested sub-basins that ranged in size from 3 to 11,000 ha were sampled repeatedly under baseflow conditions. These synoptic surveys showed a pattern of heterogeneity in headwaters that converged to a consistent response at larger basin sizes and is consistent with findings of other studies. In addition to characterizing spatial patterns under baseflow, we sampled rainfall and snowmelt events over a gradient of basin sizes to investigate scaling responses under different flow conditions. During high flow events, DOC and nitrate flushing responses varied among different basins where high-frequency event samples were collected. While the DOC and nitrate concentration patterns were similar at four headwater basins, the concentration responses of larger basins were markedly different in that the concentration patterns, flushing duration, and maximum concentrations were attenuated from headwaters to the largest basin. We are using these data to explore how flow paths and solute mixing aggregate. Overall, these results highlight the complexities of understanding spatial scaling issues in catchments and underscore the need to consider event responses of hydrology and chemistry among catchments.
Livi, Kenneth J T; Villalobos, Mario; Leary, Rowan; Varela, Maria; Barnard, Jon; Villacís-García, Milton; Zanella, Rodolfo; Goodridge, Anna; Midgley, Paul
2017-09-12
Two synthetic goethites of varying crystal size distributions were analyzed by BET, conventional TEM, cryo-TEM, atomic resolution STEM and HRTEM, and electron tomography in order to determine the effects of crystal size, shape, and atomic scale surface roughness on their adsorption capacities. The two samples were determined by BET to have very different site densities based on Cr VI adsorption experiments. Model specific surface areas generated from TEM observations showed that, based on size and shape, there should be little difference in their adsorption capacities. Electron tomography revealed that both samples crystallized with an asymmetric {101} tablet habit. STEM and HRTEM images showed a significant increase in atomic-scale surface roughness of the larger goethite. This difference in roughness was quantified based on measurements of relative abundances of crystal faces {101} and {201} for the two goethites, and a reactive surface site density was calculated for each goethite. Singly coordinated sites on face {210} are 2.5 more dense than on face {101}, and the larger goethite showed an average total of 36% {210} as compared to 14% for the smaller goethite. This difference explains the considerably larger adsorption capacitiy of the larger goethite vs the smaller sample and points toward the necessity of knowing the atomic scale surface structure in predicting mineral adsorption processes.
Structure of Nano-sized CeO 2 Materials: Combined Scattering and Spectroscopic Investigations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marchbank, Huw R.; Clark, Adam H.; Hyde, Timothy I.
Here, the nature of nano-sized ceria, CeO 2, systems were investigated using neutron and X-ray diffraction and X-ray absorption spectroscopy. Whilst both diffraction andtotal pair distribution functions (PDFs) revealed that in all the samples the occupancy of both Ce 4+ and O 2- are very close to the ideal stoichiometry, the analysis using reverse Monte Carlo technique revealedsignificant disorder around oxygen atoms in the nano sized ceria samples in comparison to the highly crystalline NIST standard.In addition, the analysis reveal that the main differences observed in the pair correlations from various X-ray and neutron diffraction techniques were attributed to themore » particle size of the CeO 2 prepared by the reported three methods. Furthermore, detailed analysis of the Ce L 3– and K-edge EXAFS data support this finding; in particular the decrease in higher shell coordination numbers with respect to the NIST standard, are attributed to differences in particle size.« less
Structure of Nano-sized CeO 2 Materials: Combined Scattering and Spectroscopic Investigations
Marchbank, Huw R.; Clark, Adam H.; Hyde, Timothy I.; ...
2016-08-29
Here, the nature of nano-sized ceria, CeO 2, systems were investigated using neutron and X-ray diffraction and X-ray absorption spectroscopy. Whilst both diffraction andtotal pair distribution functions (PDFs) revealed that in all the samples the occupancy of both Ce 4+ and O 2- are very close to the ideal stoichiometry, the analysis using reverse Monte Carlo technique revealedsignificant disorder around oxygen atoms in the nano sized ceria samples in comparison to the highly crystalline NIST standard.In addition, the analysis reveal that the main differences observed in the pair correlations from various X-ray and neutron diffraction techniques were attributed to themore » particle size of the CeO 2 prepared by the reported three methods. Furthermore, detailed analysis of the Ce L 3– and K-edge EXAFS data support this finding; in particular the decrease in higher shell coordination numbers with respect to the NIST standard, are attributed to differences in particle size.« less
Karumendu, L U; Ven, R van de; Kerr, M J; Lanza, M; Hopkins, D L
2009-08-01
The impact of homogenization speed on Particle Size (PS) results was examined using samples from the M.longissimus thoracis et lumborum (LL) of 40 lambs. One gram duplicate samples from meat aged for 1 and 5days were homogenized at five different speeds; 11,000, 13,000, 16,000, 19,000 and 22,000rpm. In addition to this LL samples from 30 different lamb carcases also aged for 1 and 5days were used to study the comparison between PS and myofibrillar fragmentation index (MFI) values. In this case, 1g duplicate samples (n=30) were homogenized at 16,000rpm and the other half (0.5g samples) at 11,000rpm (n=30). The homogenates were then subjected to respective combinations of treatments which included either PS analysis or the determination of MFI, both with or without three cycles of centrifugation. All 140 samples of LL included 65g blocks for subsequent shear force (SF) testing. Homogenization at 16,000rpm provided the greatest ability to detect ageing differences for particle size between samples aged for 1 and 5days. Particle size at the 25% quantile provided the best result for detecting differences due to ageing. It was observed that as ageing increased the mean PS decreased and was significantly (P<0.001) less for 5days aged samples compared to 1day aged samples, while MFI values significantly increased (P<0.001) as ageing period increased. When comparing the PS and MFI methods it became apparent that, as opposed to the MFI method, there was a greater coefficient of variation for the PS method which warranted a quality assurance system. Given this requirement and examination of the mean, standard deviation and the 25% quantile for PS data it was concluded that three cycles of centrifugation were not necessary and this also applied to the MFI method. There were significant correlations (P<0.001) within the same lamb loin sample aged for a given period between mean MFI and mean PS (-0.53), mean MFI and mean SF (-0.38) and mean PS and mean SF (0.23). It was concluded that PS analysis offers significant potential for streamlining determination of myofibrillar degradation when samples are measured after homogenization at 16,000rpm with no centrifugation.
Martínez, Kenia; Janssen, Joost; Pineda-Pardo, José Ángel; Carmona, Susanna; Román, Francisco Javier; Alemán-Gómez, Yasser; Garcia-Garcia, David; Escorial, Sergio; Quiroga, María Ángeles; Santarnecchi, Emiliano; Navas-Sánchez, Francisco Javier; Desco, Manuel; Arango, Celso; Colom, Roberto
2017-07-15
Global structural brain connectivity has been reported to be sex-dependent with women having increased interhemispheric connectivity (InterHc) and men having greater intrahemispheric connectivity (IntraHc). However, (a) smaller brains show greater InterHc, (b) larger brains show greater IntraHc, and (c) women have, on average, smaller brains than men. Therefore, sex differences in brain size may modulate sex differences in global brain connectivity. At the behavioural level, sex-dependent differences in connectivity are thought to contribute to men-women differences in spatial and verbal abilities. But this has never been tested at the individual level. The current study assessed whether individual differences in global structural connectome measures (InterHc, IntraHc and the ratio of InterHc relative to IntraHc) predict spatial and verbal ability while accounting for the effect of sex and brain size. The sample included forty men and forty women, who did neither differ in age nor in verbal and spatial latent components defined by a broad battery of tests and tasks. High-resolution T 1 -weighted and diffusion-weighted images were obtained for computing brain size and reconstructing the structural connectome. Results showed that men had higher IntraHc than women, while women had an increased ratio InterHc/IntraHc. However, these sex differences were modulated by brain size. Increased InterHc relative to IntraHc predicted higher spatial and verbal ability irrespective of sex and brain size. The positive correlations between the ratio InterHc/IntraHc and the spatial and verbal abilities were confirmed in 1000 random samples generated by bootstrapping. Therefore, sex differences in global structural connectome connectivity were modulated by brain size and did not underlie sex differences in verbal and spatial abilities. Rather, the level of dominance of InterHc over IntraHc may be associated with individual differences in verbal and spatial abilities in both men and women. Copyright © 2017 Elsevier Inc. All rights reserved.
Study on extrusion process of SiC ceramic matrix
NASA Astrophysics Data System (ADS)
Dai, Xiao-Yuan; Shen, Fan; Ji, Jia-You; Wang, Shu-Ling; Xu, Man
2017-11-01
In this thesis, the extrusion process of SiC ceramic matrix has been systematically studied.The effect of different cellulose content on the flexural strength and pore size distribution of SiC matrix was discussed.Reselts show that with the increase of cellulose content, the flexural strength decreased.The pore size distribution in the sample was 1um-4um, and the 1um-2um concentration was more concentrated. It is found that the cellulose content has little effect on the pore size distribution.When the cellulose content is 7%, the flexural strength of the sample is 40.9Mpa. At this time, the mechanical properties of the sample are the strongest.
Walker, Sue; Oosterhuis, Derrick M.; Wiebe, Herman H.
1984-01-01
Evaporative losses from the cut edge of leaf samples are of considerable importance in measurements of leaf water potential using thermocouple psychrometers. The ratio of cut surface area to leaf sample volume (area to volume ratio) has been used to give an estimate of possible effects of evaporative loss in relation to sample size. A wide range of sample sizes with different area to volume ratios has been used. Our results using Glycine max L. Merr. cv Bragg indicate that leaf samples with area to volume values less than 0.2 square millimeter per cubic millimeter give psychrometric leaf water potential measurements that compare favorably with pressure chamber measurements. PMID:16663578
Power of tests of normality for detecting contaminated normal samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thode, H.C. Jr.; Smith, L.A.; Finch, S.J.
1981-01-01
Seventeen tests of normality or goodness of fit were evaluated for power at detecting a contaminated normal sample. This study used 1000 replications each of samples of size 12, 17, 25, 33, 50, and 100 from six different contaminated normal distributions. The kurtosis test was the most powerful over all sample sizes and contaminations. The Hogg and weighted Kolmogorov-Smirnov tests were second. The Kolmogorov-Smirnov, chi-squared, Anderson-Darling, and Cramer-von-Mises tests had very low power at detecting contaminated normal random variables. Tables of the power of the tests and the power curves of certain tests are given.
Porosity of the Marcellus Shale: A contrast matching small-angle neutron scattering study
Bahadur, Jitendra; Ruppert, Leslie F.; Pipich, Vitaliy; Sakurovs, Richard; Melnichenko, Yuri B.
2018-01-01
Neutron scattering techniques were used to determine the effect of mineral matter on the accessibility of water and toluene to pores in the Devonian Marcellus Shale. Three Marcellus Shale samples, representing quartz-rich, clay-rich, and carbonate-rich facies, were examined using contrast matching small-angle neutron scattering (CM-SANS) at ambient pressure and temperature. Contrast matching compositions of H2O, D2O and toluene, deuterated toluene were used to probe open and closed pores of these three shale samples. Results show that although the mean pore radius was approximately the same for all three samples, the fractal dimension of the quartz-rich sample was higher than for the clay-rich and carbonate-rich samples, indicating different pore size distributions among the samples. The number density of pores was highest in the clay-rich sample and lowest in the quartz-rich sample. Contrast matching with water and toluene mixtures shows that the accessibility of pores to water and toluene also varied among the samples. In general, water accessed approximately 70–80% of the larger pores (>80 nm radius) in all three samples. At smaller pore sizes (~5–80 nm radius), the fraction of accessible pores decreases. The lowest accessibility to both fluids is at pore throat size of ~25 nm radii with the quartz-rich sample exhibiting lower accessibility than the clay- and carbonate-rich samples. The mechanism for this behaviour is unclear, but because the mineralogy of the three samples varies, it is likely that the inaccessible pores in this size range are associated with organics and not a specific mineral within the samples. At even smaller pore sizes (~<2.5 nm radius), in all samples, the fraction of accessible pores to water increases again to approximately 70–80%. Accessibility to toluene generally follows that of water; however, in the smallest pores (~<2.5 nm radius), accessibility to toluene decreases, especially in the clay-rich sample which contains about 30% more closed pores than the quartz- and carbonate-rich samples. Results from this study show that mineralogy of producing intervals within a shale reservoir can affect accessibility of pores to water and toluene and these mineralogic differences may affect hydrocarbon storage and production and hydraulic fracturing characteristics
Estuarine sediment toxicity tests on diatoms: Sensitivity comparison for three species
NASA Astrophysics Data System (ADS)
Moreno-Garrido, Ignacio; Lubián, Luis M.; Jiménez, Begoña; Soares, Amadeu M. V. M.; Blasco, Julián
2007-01-01
Experimental populations of three marine and estuarine diatoms were exposed to sediments with different levels of pollutants, collected from the Aveiro Lagoon (NW of Portugal). The species selected were Cylindrotheca closterium, Phaeodactylum tricornutum and Navicula sp. Previous experiments were designed to determine the influence of the sediment particle size distribution on growth of the species assayed. Percentage of silt-sized sediment affect to growth of the selected species in the experimental conditions: the higher percentage of silt-sized sediment, the lower growth. In any case, percentages of silt-sized sediment less than 10% did not affect growth. In general, C. closterium seems to be slightly more sensitive to the selected sediments than the other two species. Two groups of sediment samples were determined as a function of the general response of the exposed microalgal populations: three of the six samples used were more toxic than the other three. Chemical analysis of the samples was carried out in order to determine the specific cause of differences in toxicity. After a statistical analysis, concentrations of Sn, Zn, Hg, Cu and Cr (among all physico-chemical analyzed parameters), in order of importance, were the most important factors that divided the two groups of samples (more and less toxic samples). Benthic diatoms seem to be sensitive organisms in sediment toxicity tests. Toxicity data from bioassays involving microphytobentos should be taken into account when environmental risks are calculated.
Crack identification and evolution law in the vibration failure process of loaded coal
NASA Astrophysics Data System (ADS)
Li, Chengwu; Ai, Dihao; Sun, Xiaoyuan; Xie, Beijing
2017-08-01
To study the characteristics of coal cracks produced in the vibration failure process, we set up a static load and static and dynamic combination load failure test simulation system, prepared with different particle size, formation pressure, and firmness coefficient coal samples. Through static load damage testing of coal samples and then dynamic load (vibration exciter) and static (jack) combination destructive testing, the crack images of coal samples under the load condition were obtained. Combined with digital image processing technology, an algorithm of crack identification with high precision and in real-time is proposed. With the crack features of the coal samples under different load conditions as the research object, we analyzed the distribution of cracks on the surface of the coal samples and the factors influencing crack evolution using the proposed algorithm and a high-resolution industrial camera. Experimental results showed that the major portion of the crack after excitation is located in the rear of the coal sample where the vibration exciter cannot act. Under the same disturbance conditions, crack size and particle size exhibit a positive correlation, while crack size and formation pressure exhibit a negative correlation. Soft coal is more likely to lead to crack evolution than hard coal, and more easily causes instability failure. The experimental results and crack identification algorithm provide a solid basis for the prevention and control of instability and failure of coal and rock mass, and they are helpful in improving the monitoring method of coal and rock dynamic disasters.
Šmarda, Petr; Bureš, Petr; Horová, Lucie
2007-01-01
Background and Aims The spatial and statistical distribution of genome sizes and the adaptivity of genome size to some types of habitat, vegetation or microclimatic conditions were investigated in a tetraploid population of Festuca pallens. The population was previously documented to vary highly in genome size and is assumed as a model for the study of the initial stages of genome size differentiation. Methods Using DAPI flow cytometry, samples were measured repeatedly with diploid Festuca pallens as the internal standard. Altogether 172 plants from 57 plots (2·25 m2), distributed in contrasting habitats over the whole locality in South Moravia, Czech Republic, were sampled. The differences in DNA content were confirmed by the double peaks of simultaneously measured samples. Key Results At maximum, a 1·115-fold difference in genome size was observed. The statistical distribution of genome sizes was found to be continuous and best fits the extreme (Gumbel) distribution with rare occurrences of extremely large genomes (positive-skewed), as it is similar for the log-normal distribution of the whole Angiosperms. Even plants from the same plot frequently varied considerably in genome size and the spatial distribution of genome sizes was generally random and unautocorrelated (P > 0·05). The observed spatial pattern and the overall lack of correlations of genome size with recognized vegetation types or microclimatic conditions indicate the absence of ecological adaptivity of genome size in the studied population. Conclusions These experimental data on intraspecific genome size variability in Festuca pallens argue for the absence of natural selection and the selective non-significance of genome size in the initial stages of genome size differentiation, and corroborate the current hypothetical model of genome size evolution in Angiosperms (Bennetzen et al., 2005, Annals of Botany 95: 127–132). PMID:17565968
Donegan, Thomas M.
2018-01-01
Abstract Existing models for assigning species, subspecies, or no taxonomic rank to populations which are geographically separated from one another were analyzed. This was done by subjecting over 3,000 pairwise comparisons of vocal or biometric data based on birds to a variety of statistical tests that have been proposed as measures of differentiation. One current model which aims to test diagnosability (Isler et al. 1998) is highly conservative, applying a hard cut-off, which excludes from consideration differentiation below diagnosis. It also includes non-overlap as a requirement, a measure which penalizes increases to sample size. The “species scoring” model of Tobias et al. (2010) involves less drastic cut-offs, but unlike Isler et al. (1998), does not control adequately for sample size and attributes scores in many cases to differentiation which is not statistically significant. Four different models of assessing effect sizes were analyzed: using both pooled and unpooled standard deviations and controlling for sample size using t-distributions or omitting to do so. Pooled standard deviations produced more conservative effect sizes when uncontrolled for sample size but less conservative effect sizes when so controlled. Pooled models require assumptions to be made that are typically elusive or unsupported for taxonomic studies. Modifications to improving these frameworks are proposed, including: (i) introducing statistical significance as a gateway to attributing any weighting to findings of differentiation; (ii) abandoning non-overlap as a test; (iii) recalibrating Tobias et al. (2010) scores based on effect sizes controlled for sample size using t-distributions. A new universal method is proposed for measuring differentiation in taxonomy using continuous variables and a formula is proposed for ranking allopatric populations. This is based first on calculating effect sizes using unpooled standard deviations, controlled for sample size using t-distributions, for a series of different variables. All non-significant results are excluded by scoring them as zero. Distance between any two populations is calculated using Euclidian summation of non-zeroed effect size scores. If the score of an allopatric pair exceeds that of a related sympatric pair, then the allopatric population can be ranked as species and, if not, then at most subspecies rank should be assigned. A spreadsheet has been programmed and is being made available which allows this and other tests of differentiation and rank studied in this paper to be rapidly analyzed. PMID:29780266
Fitts, Douglas A
2017-09-21
The variable criteria sequential stopping rule (vcSSR) is an efficient way to add sample size to planned ANOVA tests while holding the observed rate of Type I errors, α o , constant. The only difference from regular null hypothesis testing is that criteria for stopping the experiment are obtained from a table based on the desired power, rate of Type I errors, and beginning sample size. The vcSSR was developed using between-subjects ANOVAs, but it should work with p values from any type of F test. In the present study, the α o remained constant at the nominal level when using the previously published table of criteria with repeated measures designs with various numbers of treatments per subject, Type I error rates, values of ρ, and four different sample size models. New power curves allow researchers to select the optimal sample size model for a repeated measures experiment. The criteria held α o constant either when used with a multiple correlation that varied the sample size model and the number of predictor variables, or when used with MANOVA with multiple groups and two levels of a within-subject variable at various levels of ρ. Although not recommended for use with χ 2 tests such as the Friedman rank ANOVA test, the vcSSR produces predictable results based on the relation between F and χ 2 . Together, the data confirm the view that the vcSSR can be used to control Type I errors during sequential sampling with any t- or F-statistic rather than being restricted to certain ANOVA designs.
40 CFR 796.2750 - Sediment and soil adsorption isotherm.
Code of Federal Regulations, 2011 CFR
2011-07-01
... size analysis” is the determination of the various amounts of the different particle sizes in a sample... °C. (iii) Replications. Three replications of the experimental treatments shall be used. (iv) Soil...) Decrease the water content, air or oven-dry soils at or below 50 °C. (B) Reduce aggregate size before and...
40 CFR 796.2750 - Sediment and soil adsorption isotherm.
Code of Federal Regulations, 2010 CFR
2010-07-01
... size analysis” is the determination of the various amounts of the different particle sizes in a sample... °C. (iii) Replications. Three replications of the experimental treatments shall be used. (iv) Soil...) Decrease the water content, air or oven-dry soils at or below 50 °C. (B) Reduce aggregate size before and...
Engblom, Henrik; Heiberg, Einar; Erlinge, David; Jensen, Svend Eggert; Nordrehaug, Jan Erik; Dubois-Randé, Jean-Luc; Halvorsen, Sigrun; Hoffmann, Pavel; Koul, Sasha; Carlsson, Marcus; Atar, Dan; Arheden, Håkan
2016-03-09
Cardiac magnetic resonance (CMR) can quantify myocardial infarct (MI) size and myocardium at risk (MaR), enabling assessment of myocardial salvage index (MSI). We assessed how MSI impacts the number of patients needed to reach statistical power in relation to MI size alone and levels of biochemical markers in clinical cardioprotection trials and how scan day affect sample size. Controls (n=90) from the recent CHILL-MI and MITOCARE trials were included. MI size, MaR, and MSI were assessed from CMR. High-sensitivity troponin T (hsTnT) and creatine kinase isoenzyme MB (CKMB) levels were assessed in CHILL-MI patients (n=50). Utilizing distribution of these variables, 100 000 clinical trials were simulated for calculation of sample size required to reach sufficient power. For a treatment effect of 25% decrease in outcome variables, 50 patients were required in each arm using MSI compared to 93, 98, 120, 141, and 143 for MI size alone, hsTnT (area under the curve [AUC] and peak), and CKMB (AUC and peak) in order to reach a power of 90%. If average CMR scan day between treatment and control arms differed by 1 day, sample size needs to be increased by 54% (77 vs 50) to avoid scan day bias masking a treatment effect of 25%. Sample size in cardioprotection trials can be reduced 46% to 65% without compromising statistical power when using MSI by CMR as an outcome variable instead of MI size alone or biochemical markers. It is essential to ensure lack of bias in scan day between treatment and control arms to avoid compromising statistical power. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Song, Rui; Kosorok, Michael R.; Cai, Jianwen
2009-01-01
Summary Recurrent events data are frequently encountered in clinical trials. This article develops robust covariate-adjusted log-rank statistics applied to recurrent events data with arbitrary numbers of events under independent censoring and the corresponding sample size formula. The proposed log-rank tests are robust with respect to different data-generating processes and are adjusted for predictive covariates. It reduces to the Kong and Slud (1997, Biometrika 84, 847–862) setting in the case of a single event. The sample size formula is derived based on the asymptotic normality of the covariate-adjusted log-rank statistics under certain local alternatives and a working model for baseline covariates in the recurrent event data context. When the effect size is small and the baseline covariates do not contain significant information about event times, it reduces to the same form as that of Schoenfeld (1983, Biometrics 39, 499–503) for cases of a single event or independent event times within a subject. We carry out simulations to study the control of type I error and the comparison of powers between several methods in finite samples. The proposed sample size formula is illustrated using data from an rhDNase study. PMID:18162107
A Bayesian sequential design with adaptive randomization for 2-sided hypothesis test.
Yu, Qingzhao; Zhu, Lin; Zhu, Han
2017-11-01
Bayesian sequential and adaptive randomization designs are gaining popularity in clinical trials thanks to their potentials to reduce the number of required participants and save resources. We propose a Bayesian sequential design with adaptive randomization rates so as to more efficiently attribute newly recruited patients to different treatment arms. In this paper, we consider 2-arm clinical trials. Patients are allocated to the 2 arms with a randomization rate to achieve minimum variance for the test statistic. Algorithms are presented to calculate the optimal randomization rate, critical values, and power for the proposed design. Sensitivity analysis is implemented to check the influence on design by changing the prior distributions. Simulation studies are applied to compare the proposed method and traditional methods in terms of power and actual sample sizes. Simulations show that, when total sample size is fixed, the proposed design can obtain greater power and/or cost smaller actual sample size than the traditional Bayesian sequential design. Finally, we apply the proposed method to a real data set and compare the results with the Bayesian sequential design without adaptive randomization in terms of sample sizes. The proposed method can further reduce required sample size. Copyright © 2017 John Wiley & Sons, Ltd.
Age Differences in Personality: Evidence from a Nationally Representative Australian Sample
ERIC Educational Resources Information Center
Lucas, Richard E.; Donnellan, M. Brent
2009-01-01
Cross-sectional age differences in the Big Five personality traits were examined in a nationally representative sample of Australians (N = 12,618; age range = 15-84). Extraversion, Neuroticism, and Openness were negatively associated with age, whereas Agreeableness and Conscientiousness were positively associated with age. Effect sizes comparing…
Pupil size in Jewish theological seminary students.
Shemesh, G; Kesler, A; Lazar, M; Rothkoff, L
2004-01-01
To investigate the authors' clinical impression that pupil size among myopic Jewish theological seminary students is different from pupil size of similar secular subjects. This cross-sectional study was conducted on 28 male Jewish theological seminary students and 28 secular students or workers who were matched for age and refraction. All participants were consecutively enrolled. Scotopic and photopic pupil size was measured by means of a Colvard pupillometer. Comparisons of various parameters between the groups were performed using the two-sample t-test, Fisher exact test, a paired-sample t-test, a two-way analysis of variance, and Pearson correlation coefficients as appropriate. The two groups were statistically matched for age, refraction, and visual acuity. The seminary students were undercorrected by an average of 2.35 diopters (D), while the secular subjects were undercorrected by only 0.65 D (p<0.01). The average pupil size was larger in the religious group under both scotopic and photopic luminance. This difference was maintained when the two groups were compared according to iris color under both conditions, reaching a level of statistical significance (p<0.0001). There was a significant difference in photopic pupil size between dark and light irises (p=0.049), but this difference was not maintained under scotopic conditions. The average pupil size of young ultraorthodox seminary students was significantly larger than that of matched secular subjects. Whether this is the result of intensive close-up work or of apparently characteristic undercorrection of the myopia is undetermined.
On the role of the grain size in the magnetic behavior of sintered permanent magnets
NASA Astrophysics Data System (ADS)
Efthimiadis, K. G.; Ntallis, N.
2018-02-01
In this work the finite elements method is used to simulate, by micromagnetic modeling, the magnetic behavior of sintered anisotropic magnets. Hysteresis loops were simulated for different grain sizes in an oriented multigrain sample. By keeping out other parameters that contribute to the magnetic microstructure, such as the sample size, the grain morphology and the grain boundaries mismatch, it has been found that the grain size affects the magnetic properties only if the grains are exchange-decoupled. In this case, as the grain size decreases, a decrease in the nucleation field of a reverse magnetic domain is observed and an increase in the coercive field due to the pinning of the magnetic domain walls at the grain boundaries.
Robust gene selection methods using weighting schemes for microarray data analysis.
Kang, Suyeon; Song, Jongwoo
2017-09-02
A common task in microarray data analysis is to identify informative genes that are differentially expressed between two different states. Owing to the high-dimensional nature of microarray data, identification of significant genes has been essential in analyzing the data. However, the performances of many gene selection techniques are highly dependent on the experimental conditions, such as the presence of measurement error or a limited number of sample replicates. We have proposed new filter-based gene selection techniques, by applying a simple modification to significance analysis of microarrays (SAM). To prove the effectiveness of the proposed method, we considered a series of synthetic datasets with different noise levels and sample sizes along with two real datasets. The following findings were made. First, our proposed methods outperform conventional methods for all simulation set-ups. In particular, our methods are much better when the given data are noisy and sample size is small. They showed relatively robust performance regardless of noise level and sample size, whereas the performance of SAM became significantly worse as the noise level became high or sample size decreased. When sufficient sample replicates were available, SAM and our methods showed similar performance. Finally, our proposed methods are competitive with traditional methods in classification tasks for microarrays. The results of simulation study and real data analysis have demonstrated that our proposed methods are effective for detecting significant genes and classification tasks, especially when the given data are noisy or have few sample replicates. By employing weighting schemes, we can obtain robust and reliable results for microarray data analysis.
Hislop, Jenni; Adewuyi, Temitope E; Vale, Luke D; Harrild, Kirsten; Fraser, Cynthia; Gurung, Tara; Altman, Douglas G; Briggs, Andrew H; Fayers, Peter; Ramsay, Craig R; Norrie, John D; Harvey, Ian M; Buckley, Brian; Cook, Jonathan A
2014-05-01
Randomised controlled trials (RCTs) are widely accepted as the preferred study design for evaluating healthcare interventions. When the sample size is determined, a (target) difference is typically specified that the RCT is designed to detect. This provides reassurance that the study will be informative, i.e., should such a difference exist, it is likely to be detected with the required statistical precision. The aim of this review was to identify potential methods for specifying the target difference in an RCT sample size calculation. A comprehensive systematic review of medical and non-medical literature was carried out for methods that could be used to specify the target difference for an RCT sample size calculation. The databases searched were MEDLINE, MEDLINE In-Process, EMBASE, the Cochrane Central Register of Controlled Trials, the Cochrane Methodology Register, PsycINFO, Science Citation Index, EconLit, the Education Resources Information Center (ERIC), and Scopus (for in-press publications); the search period was from 1966 or the earliest date covered, to between November 2010 and January 2011. Additionally, textbooks addressing the methodology of clinical trials and International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) tripartite guidelines for clinical trials were also consulted. A narrative synthesis of methods was produced. Studies that described a method that could be used for specifying an important and/or realistic difference were included. The search identified 11,485 potentially relevant articles from the databases searched. Of these, 1,434 were selected for full-text assessment, and a further nine were identified from other sources. Fifteen clinical trial textbooks and the ICH tripartite guidelines were also reviewed. In total, 777 studies were included, and within them, seven methods were identified-anchor, distribution, health economic, opinion-seeking, pilot study, review of the evidence base, and standardised effect size. A variety of methods are available that researchers can use for specifying the target difference in an RCT sample size calculation. Appropriate methods may vary depending on the aim (e.g., specifying an important difference versus a realistic difference), context (e.g., research question and availability of data), and underlying framework adopted (e.g., Bayesian versus conventional statistical approach). Guidance on the use of each method is given. No single method provides a perfect solution for all contexts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rather, Sami ullah, E-mail: rathersami@gmail.com
2014-12-15
Graphical abstract: X-ray diffraction (XRD) pattern of magnesium nanoparticles synthesized by solution reduction method with and without TOPO. - Highlights: • Simple and convenient method of preparing Mg nanoparticles. • Characterized by XRD, SEM, FESEM and TEM. • Trioctylphosphine oxide offers a greater control over the size of the particles. • Hydrogen uptake of samples at different temperatures and pressure of 4.5 MPa. - Abstract: Facile and simple, surfactant-mediated solution reduction method was used to synthesize monodisperse magnesium nanoparticles. Little amount of magnesium oxide nanoparticles were also formed due to the presence of TOPO and easy oxidation of magnesium, eventhough,more » all precautions were taken to avoid oxidation of the sample. Precise size control of particles was achieved by carefully varying the concentration ratio of two different types of surfactants, – trioctylphosphine oxide and hexadecylamine. Recrystallized magnesium nanoparticle samples with and without TOPO were analyzed by X-ray diffraction, scanning electron microscope, field emission scanning electron microscope, and transmission electron microscope. The peak diameters of particles were estimated from size distribution analysis of the morphological data. The particles synthesized in the presence and absence of TOPO found to have diameters 46.5 and 34.8 nm, respectively. This observed dependence of particle size on the presence of TOPO offers a convenient method to control the particle size by simply using appropriate surfactant concentrations. Exceptional enhancement in hydrogen uptake and kinetics in synthesized magnesium nanoparticles as compared to commercial magnesium sample was due to the smaller particle size and improved morphology. Overall hydrogen uptake not affected by the little variation in particle size with and without TOPO.« less
Soultan, Alaaeldin; Safi, Kamran
2017-01-01
Digitized species occurrence data provide an unprecedented source of information for ecologists and conservationists. Species distribution model (SDM) has become a popular method to utilise these data for understanding the spatial and temporal distribution of species, and for modelling biodiversity patterns. Our objective is to study the impact of noise in species occurrence data (namely sample size and positional accuracy) on the performance and reliability of SDM, considering the multiplicative impact of SDM algorithms, species specialisation, and grid resolution. We created a set of four 'virtual' species characterized by different specialisation levels. For each of these species, we built the suitable habitat models using five algorithms at two grid resolutions, with varying sample sizes and different levels of positional accuracy. We assessed the performance and reliability of the SDM according to classic model evaluation metrics (Area Under the Curve and True Skill Statistic) and model agreement metrics (Overall Concordance Correlation Coefficient and geographic niche overlap) respectively. Our study revealed that species specialisation had by far the most dominant impact on the SDM. In contrast to previous studies, we found that for widespread species, low sample size and low positional accuracy were acceptable, and useful distribution ranges could be predicted with as few as 10 species occurrences. Range predictions for narrow-ranged species, however, were sensitive to sample size and positional accuracy, such that useful distribution ranges required at least 20 species occurrences. Against expectations, the MAXENT algorithm poorly predicted the distribution of specialist species at low sample size.
NASA Astrophysics Data System (ADS)
El-Sayed, Karimat; Mohamed, Mohamed Bakr; Hamdy, Sh.; Ata-Allah, S. S.
2017-02-01
Nano-crystalline NiFe2O4 was synthesized by citrate and sol-gel methods at different annealing temperatures and the results were compared with a bulk sample prepared by ceramic method. The effect of methods of preparation and different annealing temperatures on the crystallize size, strain, bond lengths, bond angles, cations distribution and degree of inversions were investigated by X-ray powder diffraction, high resolution transmission electron microscope, Mössbauer effect spectrometer and vibrating sample magnetometer. The cations distributions were determined at both octahedral and tetrahedral sites using both Mössbauer effect spectroscopy and a modified Bertaut method using Rietveld method. The Mössbauer effect spectra showed a regular decrease in the hyperfine field with decreasing particle size. Saturation magnetization and coercivity are found to be affected by the particle size and the cations distribution.
Szyda, Joanna; Liu, Zengting; Zatoń-Dobrowolska, Magdalena; Wierzbicki, Heliodor; Rzasa, Anna
2008-01-01
We analysed data from a selective DNA pooling experiment with 130 individuals of the arctic fox (Alopex lagopus), which originated from 2 different types regarding body size. The association between alleles of 6 selected unlinked molecular markers and body size was tested by using univariate and multinomial logistic regression models, applying odds ratio and test statistics from the power divergence family. Due to the small sample size and the resulting sparseness of the data table, in hypothesis testing we could not rely on the asymptotic distributions of the tests. Instead, we tried to account for data sparseness by (i) modifying confidence intervals of odds ratio; (ii) using a normal approximation of the asymptotic distribution of the power divergence tests with different approaches for calculating moments of the statistics; and (iii) assessing P values empirically, based on bootstrap samples. As a result, a significant association was observed for 3 markers. Furthermore, we used simulations to assess the validity of the normal approximation of the asymptotic distribution of the test statistics under the conditions of small and sparse samples.
Big Data and Large Sample Size: A Cautionary Note on the Potential for Bias
Chambers, David A.; Glasgow, Russell E.
2014-01-01
Abstract A number of commentaries have suggested that large studies are more reliable than smaller studies and there is a growing interest in the analysis of “big data” that integrates information from many thousands of persons and/or different data sources. We consider a variety of biases that are likely in the era of big data, including sampling error, measurement error, multiple comparisons errors, aggregation error, and errors associated with the systematic exclusion of information. Using examples from epidemiology, health services research, studies on determinants of health, and clinical trials, we conclude that it is necessary to exercise greater caution to be sure that big sample size does not lead to big inferential errors. Despite the advantages of big studies, large sample size can magnify the bias associated with error resulting from sampling or study design. Clin Trans Sci 2014; Volume #: 1–5 PMID:25043853
“Magnitude-based Inference”: A Statistical Review
Welsh, Alan H.; Knight, Emma J.
2015-01-01
ABSTRACT Purpose We consider “magnitude-based inference” and its interpretation by examining in detail its use in the problem of comparing two means. Methods We extract from the spreadsheets, which are provided to users of the analysis (http://www.sportsci.org/), a precise description of how “magnitude-based inference” is implemented. We compare the implemented version of the method with general descriptions of it and interpret the method in familiar statistical terms. Results and Conclusions We show that “magnitude-based inference” is not a progressive improvement on modern statistics. The additional probabilities introduced are not directly related to the confidence interval but, rather, are interpretable either as P values for two different nonstandard tests (for different null hypotheses) or as approximate Bayesian calculations, which also lead to a type of test. We also discuss sample size calculations associated with “magnitude-based inference” and show that the substantial reduction in sample sizes claimed for the method (30% of the sample size obtained from standard frequentist calculations) is not justifiable so the sample size calculations should not be used. Rather than using “magnitude-based inference,” a better solution is to be realistic about the limitations of the data and use either confidence intervals or a fully Bayesian analysis. PMID:25051387
Formation of metallic clusters in oxide insulators by means of ion beam mixing
NASA Astrophysics Data System (ADS)
Talut, G.; Potzger, K.; Mücklich, A.; Zhou, Shengqiang
2008-04-01
The intermixing and near-interface cluster formation of Pt and FePt thin films deposited on different oxide surfaces by means of Pt+ ion irradiation and subsequent annealing was investigated. Irradiated as well as postannealed samples were investigated using high resolution transmission electron microscopy. In MgO and Y :ZrO2 covered with Pt, crystalline clusters with mean sizes of 2 and 3.5nm were found after the Pt+ irradiations with 8×1015 and 2×1016cm-2 and subsequent annealing, respectively. In MgO samples covered with FePt, clusters with mean sizes of 1 and 2nm were found after the Pt+ irradiations with 8×1015 and 2×1016cm-2 and subsequent annealing, respectively. In Y :ZrO2 samples covered with FePt, clusters up to 5nm in size were found after the Pt+ irradiation with 2×1016cm-2 and subsequent annealing. In LaAlO3 the irradiation was accompanied by a full amorphization of the host matrix and appearance of embedded clusters of different sizes. The determination of the lattice constant and thus the kind of the clusters in samples covered by FePt was hindered due to strong deviation of the electron beam by the ferromagnetic FePt.
Evolution of deep-bed filtration of engine exhaust particulates with trapped mass
DOE Office of Scientific and Technical Information (OSTI.GOV)
Viswanathan, Sandeep; Rothamer, David A.; Foster, David E.
Micro-scale filtration experiments were performed on cordierite filter samples using particulate matter (PM) generated by a spark-ignition direct-injection (SIDI) engine fueled with tier II EEE certification gasoline. Size-resolved mass and number concentrations were obtained from several engine operating conditions. The resultant mass-mobility relationships showed weak dependence on the operating condition. An integrated particle size distribution (IPSD) method was used estimate the PM mass concentration in the exhaust stream from the SIDI engine and a heavy duty diesel (HDD) engine. The average estimated mass concentration between all conditions was ~77****** % of the gravimetric measurements performed on Teflon filters. Despite themore » relatively low elemental carbon fraction (~0.4 to 0.7), the IPSD mass for stoichiometric SIDI exhaust was ~83±38 % of the gravimetric measurement. Identical cordierite filter samples with properties representative of diesel particulate filters were sequentially loaded with PM from the different SIDI engine operating conditions, in order of increasing PM mass concentration. Simultaneous particle size distribution measurements upstream and downstream of the filter sample were used to evaluate filter performance evolution and the instantaneous trapped mass within the filter for two different filter face velocities. The evolution of filtration performance for the different samples was sensitive only to trapped mass, despite using PM from a wide range of operating conditions. Higher filtration velocity resulted in a more rapid shift in the most penetrating particle size towards smaller mobility diameters.« less
Tomyn, Ronald L; Sleeth, Darrah K; Thiese, Matthew S; Larson, Rodney R
2016-01-01
In addition to chemical composition, the site of deposition of inhaled particles is important for determining the potential health effects from an exposure. As a result, the International Organization for Standardization adopted a particle deposition sampling convention. This includes extrathoracic particle deposition sampling conventions for the anterior nasal passages (ET1) and the posterior nasal and oral passages (ET2). This study assessed how well a polyurethane foam insert placed in an Institute of Occupational Medicine (IOM) sampler can match an extrathoracic deposition sampling convention, while accounting for possible static buildup in the test particles. In this way, the study aimed to assess whether neutralized particles affected the performance of this sampler for estimating extrathoracic particle deposition. A total of three different particle sizes (4.9, 9.5, and 12.8 µm) were used. For each trial, one particle size was introduced into a low-speed wind tunnel with a wind speed set a 0.2 m/s (∼40 ft/min). This wind speed was chosen to closely match the conditions of most indoor working environments. Each particle size was tested twice either neutralized, using a high voltage neutralizer, or left in its normal (non neutralized) state as standard particles. IOM samplers were fitted with a polyurethane foam insert and placed on a rotating mannequin inside the wind tunnel. Foam sampling efficiencies were calculated for all trials to compare against the normalized ET1 sampling deposition convention. The foam sampling efficiencies matched well to the ET1 deposition convention for the larger particle sizes, but had a general trend of underestimating for all three particle sizes. The results of a Wilcoxon Rank Sum Test also showed that only at 4.9 µm was there a statistically significant difference (p-value = 0.03) between the foam sampling efficiency using the standard particles and the neutralized particles. This is interpreted to mean that static buildup may be occurring and neutralizing the particles that are 4.9 µm diameter in size did affect the performance of the foam sampler when estimating extrathoracic particle deposition.
Richman, Julie D.; Livi, Kenneth J.T.; Geyh, Alison S.
2011-01-01
Increasing evidence suggests that the physicochemical properties of inhaled nanoparticles influence the resulting toxicokinetics and toxicodynamics. This report presents a method using scanning transmission electron microscopy (STEM) to measure the Mn content throughout the primary particle size distribution of welding fume particle samples collected on filters for application in exposure and health research. Dark field images were collected to assess the primary particle size distribution and energy-dispersive X-ray and electron energy loss spectroscopy were performed for measurement of Mn composition as a function of primary particle size. A manual method incorporating imaging software was used to measure the primary particle diameter and to select an integration region for compositional analysis within primary particles throughout the size range. To explore the variation in the developed metric, the method was applied to 10 gas metal arc welding (GMAW) fume particle samples of mild steel that were collected under a variety of conditions. The range of Mn composition by particle size was −0.10 to 0.19 %/nm, where a positive estimate indicates greater relative abundance of Mn increasing with primary particle size and a negative estimate conversely indicates decreasing Mn content with size. However, the estimate was only statistically significant (p<0.05) in half of the samples (n=5), which all had a positive estimate. In the remaining samples, no significant trend was measured. Our findings indicate that the method is reproducible and that differences in the abundance of Mn by primary particle size among welding fume samples can be detected. PMID:21625364
Richman, Julie D; Livi, Kenneth J T; Geyh, Alison S
2011-06-01
Increasing evidence suggests that the physicochemical properties of inhaled nanoparticles influence the resulting toxicokinetics and toxicodynamics. This report presents a method using scanning transmission electron microscopy (STEM) to measure the Mn content throughout the primary particle size distribution of welding fume particle samples collected on filters for application in exposure and health research. Dark field images were collected to assess the primary particle size distribution and energy-dispersive X-ray and electron energy loss spectroscopy were performed for measurement of Mn composition as a function of primary particle size. A manual method incorporating imaging software was used to measure the primary particle diameter and to select an integration region for compositional analysis within primary particles throughout the size range. To explore the variation in the developed metric, the method was applied to 10 gas metal arc welding (GMAW) fume particle samples of mild steel that were collected under a variety of conditions. The range of Mn composition by particle size was -0.10 to 0.19 %/nm, where a positive estimate indicates greater relative abundance of Mn increasing with primary particle size and a negative estimate conversely indicates decreasing Mn content with size. However, the estimate was only statistically significant (p<0.05) in half of the samples (n=5), which all had a positive estimate. In the remaining samples, no significant trend was measured. Our findings indicate that the method is reproducible and that differences in the abundance of Mn by primary particle size among welding fume samples can be detected.
Wang, Sue-Jane; O'Neill, Robert T; Hung, Hm James
2010-10-01
The current practice for seeking genomically favorable patients in randomized controlled clinical trials using genomic convenience samples. To discuss the extent of imbalance, confounding, bias, design efficiency loss, type I error, and type II error that can occur in the evaluation of the convenience samples, particularly when they are small samples. To articulate statistical considerations for a reasonable sample size to minimize the chance of imbalance, and, to highlight the importance of replicating the subgroup finding in independent studies. Four case examples reflecting recent regulatory experiences are used to underscore the problems with convenience samples. Probability of imbalance for a pre-specified subgroup is provided to elucidate sample size needed to minimize the chance of imbalance. We use an example drug development to highlight the level of scientific rigor needed, with evidence replicated for a pre-specified subgroup claim. The convenience samples evaluated ranged from 18% to 38% of the intent-to-treat samples with sample size ranging from 100 to 5000 patients per arm. The baseline imbalance can occur with probability higher than 25%. Mild to moderate multiple confounders yielding the same directional bias in favor of the treated group can make treatment group incomparable at baseline and result in a false positive conclusion that there is a treatment difference. Conversely, if the same directional bias favors the placebo group or there is loss in design efficiency, the type II error can increase substantially. Pre-specification of a genomic subgroup hypothesis is useful only for some degree of type I error control. Complete ascertainment of genomic samples in a randomized controlled trial should be the first step to explore if a favorable genomic patient subgroup suggests a treatment effect when there is no clear prior knowledge and understanding about how the mechanism of a drug target affects the clinical outcome of interest. When stratified randomization based on genomic biomarker status cannot be implemented in designing a pharmacogenomics confirmatory clinical trial, if there is one genomic biomarker prognostic for clinical response, as a general rule of thumb, a sample size of at least 100 patients may be needed to be considered for the lower prevalence genomic subgroup to minimize the chance of an imbalance of 20% or more difference in the prevalence of the genomic marker. The sample size may need to be at least 150, 350, and 1350, respectively, if an imbalance of 15%, 10% and 5% difference is of concern.
Interlinking backscatter, grain size and benthic community structure
NASA Astrophysics Data System (ADS)
McGonigle, Chris; Collier, Jenny S.
2014-06-01
The relationship between acoustic backscatter, sediment grain size and benthic community structure is examined using three different quantitative methods, covering image- and angular response-based approaches. Multibeam time-series backscatter (300 kHz) data acquired in 2008 off the coast of East Anglia (UK) are compared with grain size properties, macrofaunal abundance and biomass from 130 Hamon and 16 Clamshell grab samples. Three predictive methods are used: 1) image-based (mean backscatter intensity); 2) angular response-based (predicted mean grain size), and 3) image-based (1st principal component and classification) from Quester Tangent Corporation Multiview software. Relationships between grain size and backscatter are explored using linear regression. Differences in grain size and benthic community structure between acoustically defined groups are examined using ANOVA and PERMANOVA+. Results for the Hamon grab stations indicate significant correlations between measured mean grain size and mean backscatter intensity, angular response predicted mean grain size, and 1st principal component of QTC analysis (all p < 0.001). Results for the Clamshell grab for two of the methods have stronger positive correlations; mean backscatter intensity (r2 = 0.619; p < 0.001) and angular response predicted mean grain size (r2 = 0.692; p < 0.001). ANOVA reveals significant differences in mean grain size (Hamon) within acoustic groups for all methods: mean backscatter (p < 0.001), angular response predicted grain size (p < 0.001), and QTC class (p = 0.009). Mean grain size (Clamshell) shows a significant difference between groups for mean backscatter (p = 0.001); other methods were not significant. PERMANOVA for the Hamon abundance shows benthic community structure was significantly different between acoustic groups for all methods (p ≤ 0.001). Overall these results show considerable promise in that more than 60% of the variance in the mean grain size of the Clamshell grab samples can be explained by mean backscatter or acoustically-predicted grain size. These results show that there is significant predictive capacity for sediment characteristics from multibeam backscatter and that these acoustic classifications can have ecological validity.
NASA Astrophysics Data System (ADS)
Taheriniya, Shabnam; Parhizgar, Sara Sadat; Sari, Amir Hossein
2018-06-01
To study the alumina template pore size distribution as a function of Al thin film grain size distribution, porous alumina templates were prepared by anodizing sputtered aluminum thin films. To control the grain size the aluminum samples were sputtered with the rate of 0.5, 1 and 2 Å/s and the substrate temperature was either 25, 75 or 125 °C. All samples were anodized for 120 s in 1 M sulfuric acid solution kept at 1 °C while a 15 V potential was being applied. The standard deviation value for samples deposited at room temperature but with different rates is roughly 2 nm in both thin film and porous template form but it rises to approximately 4 nm with substrate temperature. Samples with the average grain size of 13, 14, 18.5 and 21 nm respectively produce alumina templates with an average pore size of 8.5, 10, 15 and 16 nm in that order which shows the average grain size limits the average pore diameter in the resulting template. Lateral correlation length and grain boundary effect are other factors that affect the pore formation process and pore size distribution by limiting the initial current density.
The effects of sample size on population genomic analyses--implications for the tests of neutrality.
Subramanian, Sankar
2016-02-20
One of the fundamental measures of molecular genetic variation is the Watterson's estimator (θ), which is based on the number of segregating sites. The estimation of θ is unbiased only under neutrality and constant population growth. It is well known that the estimation of θ is biased when these assumptions are violated. However, the effects of sample size in modulating the bias was not well appreciated. We examined this issue in detail based on large-scale exome data and robust simulations. Our investigation revealed that sample size appreciably influences θ estimation and this effect was much higher for constrained genomic regions than that of neutral regions. For instance, θ estimated for synonymous sites using 512 human exomes was 1.9 times higher than that obtained using 16 exomes. However, this difference was 2.5 times for the nonsynonymous sites of the same data. We observed a positive correlation between the rate of increase in θ estimates (with respect to the sample size) and the magnitude of selection pressure. For example, θ estimated for the nonsynonymous sites of highly constrained genes (dN/dS < 0.1) using 512 exomes was 3.6 times higher than that estimated using 16 exomes. In contrast this difference was only 2 times for the less constrained genes (dN/dS > 0.9). The results of this study reveal the extent of underestimation owing to small sample sizes and thus emphasize the importance of sample size in estimating a number of population genomic parameters. Our results have serious implications for neutrality tests such as Tajima D, Fu-Li D and those based on the McDonald and Kreitman test: Neutrality Index and the fraction of adaptive substitutions. For instance, use of 16 exomes produced 2.4 times higher proportion of adaptive substitutions compared to that obtained using 512 exomes (24% vs 10 %).
Wareham, K J; Hyde, R M; Grindlay, D; Brennan, M L; Dean, R S
2017-10-04
Randomised controlled trials (RCTs) are a key component of the veterinary evidence base. Sample sizes and defined outcome measures are crucial components of RCTs. To describe the sample size and number of outcome measures of veterinary RCTs either funded by the pharmaceutical industry or not, published in 2011. A structured search of PubMed identified RCTs examining the efficacy of pharmaceutical interventions. Number of outcome measures, number of animals enrolled per trial, whether a primary outcome was identified, and the presence of a sample size calculation were extracted from the RCTs. The source of funding was identified for each trial and groups compared on the above parameters. Literature searches returned 972 papers; 86 papers comprising 126 individual trials were analysed. The median number of outcomes per trial was 5.0; there were no significant differences across funding groups (p = 0.133). The median number of animals enrolled per trial was 30.0; this was similar across funding groups (p = 0.302). A primary outcome was identified in 40.5% of trials and was significantly more likely to be stated in trials funded by a pharmaceutical company. A very low percentage of trials reported a sample size calculation (14.3%). Failure to report primary outcomes, justify sample sizes and the reporting of multiple outcome measures was a common feature in all of the clinical trials examined in this study. It is possible some of these factors may be affected by the source of funding of the studies, but the influence of funding needs to be explored with a larger number of trials. Some veterinary RCTs provide a weak evidence base and targeted strategies are required to improve the quality of veterinary RCTs to ensure there is reliable evidence on which to base clinical decisions.
2017-01-01
Synchronization of population dynamics in different habitats is a frequently observed phenomenon. A common mathematical tool to reveal synchronization is the (cross)correlation coefficient between time courses of values of the population size of a given species where the population size is evaluated from spatial sampling data. The corresponding sampling net or grid is often coarse, i.e. it does not resolve all details of the spatial configuration, and the evaluation error—i.e. the difference between the true value of the population size and its estimated value—can be considerable. We show that this estimation error can make the value of the correlation coefficient very inaccurate or even irrelevant. We consider several population models to show that the value of the correlation coefficient calculated on a coarse sampling grid rarely exceeds 0.5, even if the true value is close to 1, so that the synchronization is effectively lost. We also observe ‘ghost synchronization’ when the correlation coefficient calculated on a coarse sampling grid is close to 1 but in reality the dynamics are not correlated. Finally, we suggest a simple test to check the sampling grid coarseness and hence to distinguish between the true and artifactual values of the correlation coefficient. PMID:28202589
Freitag, Angelika J; Shomali, Maliheh; Michalakis, Stylianos; Biel, Martin; Siedler, Michael; Kaymakcalan, Zehra; Carpenter, John F; Randolph, Theodore W; Winter, Gerhard; Engert, Julia
2015-02-01
The potential contribution of protein aggregates to the unwanted immunogenicity of protein pharmaceuticals is a major concern. In the present study a murine monoclonal antibody was utilized to study the immunogenicity of different types of aggregates in mice. Samples containing defined types of aggregates were prepared by processes such as stirring, agitation, exposure to ultraviolet (UV) light and exposure to elevated temperatures. Aggregates were analyzed by size-exclusion chromatography, light obscuration, turbidimetry, infrared (IR) spectroscopy and UV spectroscopy. Samples were separated into fractions based on aggregate size by asymmetrical flow field-flow fractionation or by centrifugation. Samples containing different types and sizes of aggregates were subsequently administered to C57BL/6 J and BALB/c mice, and serum was analyzed for the presence of anti-IgG1, anti-IgG2a, anti-IgG2b and anti-IgG3 antibodies. In addition, the pharmacokinetic profile of the murine antibody was investigated. In this study, samples containing high numbers of different types of aggregates were administered in order to challenge the in vivo system. The magnitude of immune response depends on the nature of the aggregates. The most immunogenic aggregates were of relatively large and insoluble nature, with perturbed, non-native structures. This study shows that not all protein drug aggregates are equally immunogenic.
In Situ Sampling of Relative Dust Devil Particle Loads and Their Vertical Grain Size Distributions.
Raack, Jan; Reiss, Dennis; Balme, Matthew R; Taj-Eddine, Kamal; Ori, Gian Gabriele
2017-04-19
During a field campaign in the Sahara Desert in southern Morocco, spring 2012, we sampled the vertical grain size distribution of two active dust devils that exhibited different dimensions and intensities. With these in situ samples of grains in the vortices, it was possible to derive detailed vertical grain size distributions and measurements of the lifted relative particle load. Measurements of the two dust devils show that the majority of all lifted particles were only lifted within the first meter (∼46.5% and ∼61% of all particles; ∼76.5 wt % and ∼89 wt % of the relative particle load). Furthermore, ∼69% and ∼82% of all lifted sand grains occurred in the first meter of the dust devils, indicating the occurrence of "sand skirts." Both sampled dust devils were relatively small (∼15 m and ∼4-5 m in diameter) compared to dust devils in surrounding regions; nevertheless, measurements show that ∼58.5% to 73.5% of all lifted particles were small enough to go into suspension (<31 μm, depending on the used grain size classification). This relatively high amount represents only ∼0.05 to 0.15 wt % of the lifted particle load. Larger dust devils probably entrain larger amounts of fine-grained material into the atmosphere, which can have an influence on the climate. Furthermore, our results indicate that the composition of the surface, on which the dust devils evolved, also had an influence on the particle load composition of the dust devil vortices. The internal particle load structure of both sampled dust devils was comparable related to their vertical grain size distribution and relative particle load, although both dust devils differed in their dimensions and intensities. A general trend of decreasing grain sizes with height was also detected. Key Words: Mars-Dust devils-Planetary science-Desert soils-Atmosphere-Grain sizes. Astrobiology 17, xxx-xxx.
Carter, James L.; Resh, Vincent H.
2001-01-01
A survey of methods used by US state agencies for collecting and processing benthic macroinvertebrate samples from streams was conducted by questionnaire; 90 responses were received and used to describe trends in methods. The responses represented an estimated 13,000-15,000 samples collected and processed per year. Kicknet devices were used in 64.5% of the methods; other sampling devices included fixed-area samplers (Surber and Hess), artificial substrates (Hester-Dendy and rock baskets), grabs, and dipnets. Regional differences existed, e.g., the 1-m kicknet was used more often in the eastern US than in the western US. Mesh sizes varied among programs but 80.2% of the methods used a mesh size between 500 and 600 (mu or u)m. Mesh size variations within US Environmental Protection Agency regions were large, with size differences ranging from 100 to 700 (mu or u)m. Most samples collected were composites; the mean area sampled was 1.7 m2. Samples rarely were collected using a random method (4.7%); most samples (70.6%) were collected using "expert opinion", which may make data obtained operator-specific. Only 26.3% of the methods sorted all the organisms from a sample; the remainder subsampled in the laboratory. The most common method of subsampling was to remove 100 organisms (range = 100-550). The magnification used for sorting ranged from 1 (sorting by eye) to 30x, which results in inconsistent separation of macroinvertebrates from detritus. In addition to subsampling, 53% of the methods sorted large/rare organisms from a sample. The taxonomic level used for identifying organisms varied among taxa; Ephemeroptera, Plecoptera, and Trichoptera were generally identified to a finer taxonomic resolution (genus and species) than other taxa. Because there currently exists a large range of field and laboratory methods used by state programs, calibration among all programs to increase data comparability would be exceptionally challenging. However, because many techniques are shared among methods, limited testing could be designed to evaluate whether procedural differences affect the ability to determine levels of environmental impairment using benthic macroinvertebrate communities.
Ucar Zennure; Pete Bettinger; Krista Merry; Jacek Siry; J.M. Bowker
2016-01-01
Two different sampling approaches for estimating urban tree canopy cover were applied to two medium-sized cities in the United States, in conjunction with two freely available remotely sensed imagery products. A random point-based sampling approach, which involved 1000 sample points, was compared against a plot/grid sampling (cluster sampling) approach that involved a...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakamura, Toshihiro, E-mail: nakamura@el.gunma-u.ac.jp; Watanabe, Kanta; Adachi, Sadao
2016-01-11
We reported the preparation of bright and multicolor luminescent colloidal Si nanocrystal (Si-nc) by pulsed UV laser irradiation to porous Si (PSi) in an organic solvent. The different-luminescence-color (different-sized) colloidal Si-nc was produced by the pulsed laser-induced fragmentation of different-sized porous nanostructures. The colloidal Si-nc samples were found to have higher photoluminescence quantum efficiencies (20%–23%) than the PSi samples (1%–3%). The brighter emission of the colloidal Si-nc was attributed to an enhanced radiative band-to-band transition rate due to the presence of a surface organic layer formed by UV laser-induced hydrosilylation.
Size Matters: Cerebral Volume Influences Sex Differences in Neuroanatomy
Towler, Stephen; Welcome, Suzanne; Halderman, Laura K.; Otto, Ron; Eckert, Mark A.; Chiarello, Christine
2008-01-01
Biological and behavioral differences between the sexes range from obvious to subtle or nonexistent. Neuroanatomical differences are particularly controversial, perhaps due to the implication that they might account for behavioral differences. In this sample of 200 men and women, large effect sizes (Cohen's d > 0.8) were found for sex differences in total cerebral gray and white matter, cerebellum, and gray matter proportion (women had a higher proportion of gray matter). The only one of these sex differences that survived adjustment for the effect of cerebral volume was gray matter proportion. Individual differences in cerebral volume accounted for 21% of the difference in gray matter proportion, while sex accounted for an additional 4%. The relative size of the corpus callosum was 5% larger in women, but this difference was completely explained by a negative relationship between relative callosal size and cerebral volume. In agreement with Jancke et al., individuals with higher cerebral volume tended to have smaller corpora callosa. There were few sex differences in the size of structures in Broca's and Wernicke's area. We conclude that individual differences in brain volume, in both men and women, account for apparent sex differences in relative size. PMID:18440950
NASA Astrophysics Data System (ADS)
Burritt, Rosemary; Francois, Elizabeth; Windler, Gary; Chavez, David
2017-06-01
Diaminoazoxyfurazan (DAAF) has many of the safety characteristics of an insensitive high explosive (IHE): it is extremely insensitive to impact and friction and is comparable to triaminotrinitrobezene (TATB) in this way. Conversely, it demonstrates many performance characteristics of a Conventional High Explosive (CHE). DAAF has a small failure diameter of about 1.25 mm and can be sensitive to shock under the right conditions. Large particle sized DAAF will not initiate in a typical exploding foil initiator (EFI) configuration but smaller particle sizes will. Large particle sized DAAF, of 40 μm, was crash precipitated and ball milled into six distinct samples and pressed into pellets with a density of 1.60 g/cc (91% TMD). To investigate the effect of particle size and surface area on the direct initiation on DAAF multiple threshold tests were preformed on each sample of DAAF in different EFI configurations, which varied in flyer thickness and/or bridge size. Comparative tests were performed examining threshold voltage and correlated to Photon Doppler Velocimetry (PDV) results. The samples with larger particle sizes and surface area required more energy to initiate while the smaller particle sizes required less energy and could be initiated with smaller diameter flyers.
Hromadnikova, I; Zejskova, L; Doucha, J; Codl, D
2006-11-01
Fetal extracellular DNA is mainly derived from apoptotic bodies of trophoblast. Recent studies have shown size differences between fetal and maternal extracellular DNA. We have examined the quantification of fetal (SRY gene) and total (GLO gene) extracellular DNA in maternal plasma in different fractions (100-300, 300-500, 500-700, 700-900, and >900 bp) after size fractionation by agarose gel electrophoresis. DNA was extracted from maternal plasma samples from 11 pregnant women carrying male foetuses at the 16th week of gestation. Fetal circulatory DNA was mainly detected in the 100-300 bp fraction with the median concentration being 14.4 GE/ml. A lower median amount of 4.9 GE/ml was also found in the 300-500 bp fraction. Circulatory DNA extracted from the 100-300 bp fraction contained 4.2 times enriched fetal DNA when compared with unseparated DNA sample. Fetal DNA within the 300-500 bp fraction was 2.5 times enriched. Circulatory fetal DNA is predominantly present in a fraction with molecular size <500 bp, which can be used for the detection of paternally inherited alleles. However, the usage of size-separated DNA is not suitable for routine clinical applications because of risk of contamination.
Sample size calculation in economic evaluations.
Al, M J; van Hout, B A; Michel, B C; Rutten, F F
1998-06-01
A simulation method is presented for sample size calculation in economic evaluations. As input the method requires: the expected difference and variance of costs and effects, their correlation, the significance level (alpha) and the power of the testing method and the maximum acceptable ratio of incremental effectiveness to incremental costs. The method is illustrated with data from two trials. The first compares primary coronary angioplasty with streptokinase in the treatment of acute myocardial infarction, in the second trial, lansoprazole is compared with omeprazole in the treatment of reflux oesophagitis. These case studies show how the various parameters influence the sample size. Given the large number of parameters that have to be specified in advance, the lack of knowledge about costs and their standard deviation, and the difficulty of specifying the maximum acceptable ratio of incremental effectiveness to incremental costs, the conclusion of the study is that from a technical point of view it is possible to perform a sample size calculation for an economic evaluation, but one should wonder how useful it is.
A Demonstration of Sample Segregation
ERIC Educational Resources Information Center
Fritz, Mark D.; Brumbach, Stephen B.; Hartman, JudithAnn R.
2005-01-01
The demonstration of sample segregation, which is simple, and visually compelling illustrates the importance of sample handling for students studying analytical chemistry and environmental chemistry. The mixture used in this demonstration has two components, which have big particle size, and different colors, which makes the segregation graphic.
Sample size allocation for food item radiation monitoring and safety inspection.
Seto, Mayumi; Uriu, Koichiro
2015-03-01
The objective of this study is to identify a procedure for determining sample size allocation for food radiation inspections of more than one food item to minimize the potential risk to consumers of internal radiation exposure. We consider a simplified case of food radiation monitoring and safety inspection in which a risk manager is required to monitor two food items, milk and spinach, in a contaminated area. Three protocols for food radiation monitoring with different sample size allocations were assessed by simulating random sampling and inspections of milk and spinach in a conceptual monitoring site. Distributions of (131)I and radiocesium concentrations were determined in reference to (131)I and radiocesium concentrations detected in Fukushima prefecture, Japan, for March and April 2011. The results of the simulations suggested that a protocol that allocates sample size to milk and spinach based on the estimation of (131)I and radiocesium concentrations using the apparent decay rate constants sequentially calculated from past monitoring data can most effectively minimize the potential risks of internal radiation exposure. © 2014 Society for Risk Analysis.
Liu, Xiaofeng Steven
2011-05-01
The use of covariates is commonly believed to reduce the unexplained error variance and the standard error for the comparison of treatment means, but the reduction in the standard error is neither guaranteed nor uniform over different sample sizes. The covariate mean differences between the treatment conditions can inflate the standard error of the covariate-adjusted mean difference and can actually produce a larger standard error for the adjusted mean difference than that for the unadjusted mean difference. When the covariate observations are conceived of as randomly varying from one study to another, the covariate mean differences can be related to a Hotelling's T(2) . Using this Hotelling's T(2) statistic, one can always find a minimum sample size to achieve a high probability of reducing the standard error and confidence interval width for the adjusted mean difference. ©2010 The British Psychological Society.
Effect of finite sample size on feature selection and classification: a simulation study.
Way, Ted W; Sahiner, Berkman; Hadjiiski, Lubomir M; Chan, Heang-Ping
2010-02-01
The small number of samples available for training and testing is often the limiting factor in finding the most effective features and designing an optimal computer-aided diagnosis (CAD) system. Training on a limited set of samples introduces bias and variance in the performance of a CAD system relative to that trained with an infinite sample size. In this work, the authors conducted a simulation study to evaluate the performances of various combinations of classifiers and feature selection techniques and their dependence on the class distribution, dimensionality, and the training sample size. The understanding of these relationships will facilitate development of effective CAD systems under the constraint of limited available samples. Three feature selection techniques, the stepwise feature selection (SFS), sequential floating forward search (SFFS), and principal component analysis (PCA), and two commonly used classifiers, Fisher's linear discriminant analysis (LDA) and support vector machine (SVM), were investigated. Samples were drawn from multidimensional feature spaces of multivariate Gaussian distributions with equal or unequal covariance matrices and unequal means, and with equal covariance matrices and unequal means estimated from a clinical data set. Classifier performance was quantified by the area under the receiver operating characteristic curve Az. The mean Az values obtained by resubstitution and hold-out methods were evaluated for training sample sizes ranging from 15 to 100 per class. The number of simulated features available for selection was chosen to be 50, 100, and 200. It was found that the relative performance of the different combinations of classifier and feature selection method depends on the feature space distributions, the dimensionality, and the available training sample sizes. The LDA and SVM with radial kernel performed similarly for most of the conditions evaluated in this study, although the SVM classifier showed a slightly higher hold-out performance than LDA for some conditions and vice versa for other conditions. PCA was comparable to or better than SFS and SFFS for LDA at small samples sizes, but inferior for SVM with polynomial kernel. For the class distributions simulated from clinical data, PCA did not show advantages over the other two feature selection methods. Under this condition, the SVM with radial kernel performed better than the LDA when few training samples were available, while LDA performed better when a large number of training samples were available. None of the investigated feature selection-classifier combinations provided consistently superior performance under the studied conditions for different sample sizes and feature space distributions. In general, the SFFS method was comparable to the SFS method while PCA may have an advantage for Gaussian feature spaces with unequal covariance matrices. The performance of the SVM with radial kernel was better than, or comparable to, that of the SVM with polynomial kernel under most conditions studied.
The Influence of Mark-Recapture Sampling Effort on Estimates of Rock Lobster Survival
Kordjazi, Ziya; Frusher, Stewart; Buxton, Colin; Gardner, Caleb; Bird, Tomas
2016-01-01
Five annual capture-mark-recapture surveys on Jasus edwardsii were used to evaluate the effect of sample size and fishing effort on the precision of estimated survival probability. Datasets of different numbers of individual lobsters (ranging from 200 to 1,000 lobsters) were created by random subsampling from each annual survey. This process of random subsampling was also used to create 12 datasets of different levels of effort based on three levels of the number of traps (15, 30 and 50 traps per day) and four levels of the number of sampling-days (2, 4, 6 and 7 days). The most parsimonious Cormack-Jolly-Seber (CJS) model for estimating survival probability shifted from a constant model towards sex-dependent models with increasing sample size and effort. A sample of 500 lobsters or 50 traps used on four consecutive sampling-days was required for obtaining precise survival estimations for males and females, separately. Reduced sampling effort of 30 traps over four sampling days was sufficient if a survival estimate for both sexes combined was sufficient for management of the fishery. PMID:26990561
Trattner, Sigal; Cheng, Bin; Pieniazek, Radoslaw L.; Hoffmann, Udo; Douglas, Pamela S.; Einstein, Andrew J.
2014-01-01
Purpose: Effective dose (ED) is a widely used metric for comparing ionizing radiation burden between different imaging modalities, scanners, and scan protocols. In computed tomography (CT), ED can be estimated by performing scans on an anthropomorphic phantom in which metal-oxide-semiconductor field-effect transistor (MOSFET) solid-state dosimeters have been placed to enable organ dose measurements. Here a statistical framework is established to determine the sample size (number of scans) needed for estimating ED to a desired precision and confidence, for a particular scanner and scan protocol, subject to practical limitations. Methods: The statistical scheme involves solving equations which minimize the sample size required for estimating ED to desired precision and confidence. It is subject to a constrained variation of the estimated ED and solved using the Lagrange multiplier method. The scheme incorporates measurement variation introduced both by MOSFET calibration, and by variation in MOSFET readings between repeated CT scans. Sample size requirements are illustrated on cardiac, chest, and abdomen–pelvis CT scans performed on a 320-row scanner and chest CT performed on a 16-row scanner. Results: Sample sizes for estimating ED vary considerably between scanners and protocols. Sample size increases as the required precision or confidence is higher and also as the anticipated ED is lower. For example, for a helical chest protocol, for 95% confidence and 5% precision for the ED, 30 measurements are required on the 320-row scanner and 11 on the 16-row scanner when the anticipated ED is 4 mSv; these sample sizes are 5 and 2, respectively, when the anticipated ED is 10 mSv. Conclusions: Applying the suggested scheme, it was found that even at modest sample sizes, it is feasible to estimate ED with high precision and a high degree of confidence. As CT technology develops enabling ED to be lowered, more MOSFET measurements are needed to estimate ED with the same precision and confidence. PMID:24694150
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reiser, I; Lu, Z
2014-06-01
Purpose: Recently, task-based assessment of diagnostic CT systems has attracted much attention. Detection task performance can be estimated using human observers, or mathematical observer models. While most models are well established, considerable bias can be introduced when performance is estimated from a limited number of image samples. Thus, the purpose of this work was to assess the effect of sample size on bias and uncertainty of two channelized Hotelling observers and a template-matching observer. Methods: The image data used for this study consisted of 100 signal-present and 100 signal-absent regions-of-interest, which were extracted from CT slices. The experimental conditions includedmore » two signal sizes and five different x-ray beam current settings (mAs). Human observer performance for these images was determined in 2-alternative forced choice experiments. These data were provided by the Mayo clinic in Rochester, MN. Detection performance was estimated from three observer models, including channelized Hotelling observers (CHO) with Gabor or Laguerre-Gauss (LG) channels, and a template-matching observer (TM). Different sample sizes were generated by randomly selecting a subset of image pairs, (N=20,40,60,80). Observer performance was quantified as proportion of correct responses (PC). Bias was quantified as the relative difference of PC for 20 and 80 image pairs. Results: For n=100, all observer models predicted human performance across mAs and signal sizes. Bias was 23% for CHO (Gabor), 7% for CHO (LG), and 3% for TM. The relative standard deviation, σ(PC)/PC at N=20 was highest for the TM observer (11%) and lowest for the CHO (Gabor) observer (5%). Conclusion: In order to make image quality assessment feasible in the clinical practice, a statistically efficient observer model, that can predict performance from few samples, is needed. Our results identified two observer models that may be suited for this task.« less
Computed Tomography to Estimate the Representative Elementary Area for Soil Porosity Measurements
Borges, Jaqueline Aparecida Ribaski; Pires, Luiz Fernando; Belmont Pereira, André
2012-01-01
Computed tomography (CT) is a technique that provides images of different solid and porous materials. CT could be an ideal tool to study representative sizes of soil samples because of the noninvasive characteristic of this technique. The scrutiny of such representative elementary sizes (RESs) has been the target of attention of many researchers related to soil physics field owing to the strong relationship between physical properties and size of the soil sample. In the current work, data from gamma-ray CT were used to assess RES in measurements of soil porosity (ϕ). For statistical analysis, a study on the full width at a half maximum (FWHM) of the adjustment of distribution of ϕ at different areas (1.2 to 1162.8 mm2) selected inside of tomographic images was proposed herein. The results obtained point out that samples with a section area corresponding to at least 882.1 mm2 were the ones that provided representative values of ϕ for the studied Brazilian tropical soil. PMID:22666133
NASA Astrophysics Data System (ADS)
Lahiri, B. B.; Ranoo, Surojit; Muthukumaran, T.; Philip, John
2018-04-01
The effects of initial susceptibility and size polydispersity on magnetic hyperthermia efficiency in two water based ferrofluids containing phosphate and TMAOH coated superparamagnetic Fe3O4 nanoparticles were studied. Experiments were performed at a fixed frequency of 126 kHz on four different concentrations of both samples and under different external field amplitudes. It was observed that for field amplitudes beyond 45.0 kAm-1, the maximum temperature rise was in the vicinity of 42°C (hyperthermia limit) which indicated the suitability of the water based ferrofluids for hyperthermia applications. The maximum temperature rise and specific absorption rate were found to vary linearly with square of the applied field amplitudes, in accordance with theoretical predictions. It was further observed that for a fixed sample concentration, specific absorption rate was higher for the phosphate coated samples which was attributed to the higher initial static susceptibility and lower size polydispersity of phosphate coated Fe3O4.
Boitard, Simon; Rodríguez, Willy; Jay, Flora; Mona, Stefano; Austerlitz, Frédéric
2016-01-01
Inferring the ancestral dynamics of effective population size is a long-standing question in population genetics, which can now be tackled much more accurately thanks to the massive genomic data available in many species. Several promising methods that take advantage of whole-genome sequences have been recently developed in this context. However, they can only be applied to rather small samples, which limits their ability to estimate recent population size history. Besides, they can be very sensitive to sequencing or phasing errors. Here we introduce a new approximate Bayesian computation approach named PopSizeABC that allows estimating the evolution of the effective population size through time, using a large sample of complete genomes. This sample is summarized using the folded allele frequency spectrum and the average zygotic linkage disequilibrium at different bins of physical distance, two classes of statistics that are widely used in population genetics and can be easily computed from unphased and unpolarized SNP data. Our approach provides accurate estimations of past population sizes, from the very first generations before present back to the expected time to the most recent common ancestor of the sample, as shown by simulations under a wide range of demographic scenarios. When applied to samples of 15 or 25 complete genomes in four cattle breeds (Angus, Fleckvieh, Holstein and Jersey), PopSizeABC revealed a series of population declines, related to historical events such as domestication or modern breed creation. We further highlight that our approach is robust to sequencing errors, provided summary statistics are computed from SNPs with common alleles. PMID:26943927
Size-selective separation of polydisperse gold nanoparticles in supercritical ethane.
Williams, Dylan P; Satherley, John
2009-04-09
The aim of this study was to use supercritical ethane to selectively disperse alkanethiol-stabilized gold nanoparticles of one size from a polydisperse sample in order to recover a monodisperse fraction of the nanoparticles. A disperse sample of metal nanoparticles with diameters in the range of 1-5 nm was prepared using established techniques then further purified by Soxhlet extraction. The purified sample was subjected to supercritical ethane at a temperature of 318 K in the pressure range 50-276 bar. Particles were characterized by UV-vis absorption spectroscopy, TEM, and MALDI-TOF mass spectroscopy. The results show that with increasing pressure the dispersibility of the nanoparticles increases, this effect is most pronounced for smaller nanoparticles. At the highest pressure investigated a sample of the particles was effectively stripped of all the smaller particles leaving a monodisperse sample. The relationship between dispersibility and supercritical fluid density for two different size samples of alkanethiol-stabilized gold nanoparticles was considered using the Chrastil chemical equilibrium model.
[A Review on the Use of Effect Size in Nursing Research].
Kang, Hyuncheol; Yeon, Kyupil; Han, Sang Tae
2015-10-01
The purpose of this study was to introduce the main concepts of statistical testing and effect size and to provide researchers in nursing science with guidance on how to calculate the effect size for the statistical analysis methods mainly used in nursing. For t-test, analysis of variance, correlation analysis, regression analysis which are used frequently in nursing research, the generally accepted definitions of the effect size were explained. Some formulae for calculating the effect size are described with several examples in nursing research. Furthermore, the authors present the required minimum sample size for each example utilizing G*Power 3 software that is the most widely used program for calculating sample size. It is noted that statistical significance testing and effect size measurement serve different purposes, and the reliance on only one side may be misleading. Some practical guidelines are recommended for combining statistical significance testing and effect size measure in order to make more balanced decisions in quantitative analyses.
Oillic, Samuel; Lemoine, Eric; Gros, Jean-Bernard; Kondjoyan, Alain
2011-07-01
Cooking loss kinetics were measured on cubes and parallelepipeds of beef Semimembranosus muscle ranging from 1 cm × 1 cm × 1 cm to 7 cm × 7 cm × 28 cm in size. The samples were water bath-heated at three different temperatures, i.e. 50°C, 70°C and 90°C, and for five different times. Temperatures were simulated to help interpret the results. Pre-freezing the sample, difference in ageing time, and in muscle fiber orientation had little influence on cooking losses. At longer treatment times, the effects of sample size disappeared and cooking losses depended only on the temperature. A selection of the tests was repeated on four other beef muscles and on veal, horse and lamb Semimembranosus muscle. Kinetics followed similar curves in all cases but resulted in different final water contents. The shape of the kinetics curves suggests first-order kinetics. Copyright © 2011 The American Meat Science Association. Published by Elsevier Ltd. All rights reserved.
Jian, Yu-Tao; Yang, Yue; Tian, Tian; Stanford, Clark; Zhang, Xin-Ping; Zhao, Ke
2015-01-01
Five types of porous Nickel-Titanium (NiTi) alloy samples of different porosities and pore sizes were fabricated. According to compressive and fracture strengths, three groups of porous NiTi alloy samples underwent further cytocompatibility experiments. Porous NiTi alloys exhibited a lower Young’s modulus (2.0 GPa ~ 0.8 GPa). Both compressive strength (108.8 MPa ~ 56.2 MPa) and fracture strength (64.6 MPa ~ 41.6 MPa) decreased gradually with increasing mean pore size (MPS). Cells grew and spread well on all porous NiTi alloy samples. Cells attached more strongly on control group and blank group than on all porous NiTi alloy samples (p < 0.05). Cell adhesion on porous NiTi alloys was correlated negatively to MPS (277.2 μm ~ 566.5 μm; p < 0.05). More cells proliferated on control group and blank group than on all porous NiTi alloy samples (p < 0.05). Cellular ALP activity on all porous NiTi alloy samples was higher than on control group and blank group (p < 0.05). The porous NiTi alloys with optimized pore size could be a potential orthopedic material. PMID:26047515
Soil carbon inventories under a bioenergy crop (switchgrass): Measurement limitations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garten, C.T. Jr.; Wullschleger, S.D.
Approximately 5 yr after planting, coarse root carbon (C) and soil organic C (SOC) inventories were compared under different types of plant cover at four switchgrass (Panicum virgatum L.) production field trials in the southeastern USA. There was significantly more coarse root C under switchgrass (Alamo variety) and forest cover than tall fescue (Festuca arundinacea Schreb.), corn (Zea mays L.), or native pastures of mixed grasses. Inventories of SOC under switchgrass were not significantly greater than SOC inventories under other plant covers. At some locations the statistical power associated with ANOVA of SOC inventories was low, which raised questions aboutmore » whether differences in SOC could be detected statistically. A minimum detectable difference (MDD) for SOC inventories was calculated. The MDD is the smallest detectable difference between treatment means once the variation, significance level, statistical power, and sample size are specified. The analysis indicated that a difference of {approx}50 mg SOC/cm{sup 2} or 5 Mg SOC/ha, which is {approx}10 to 15% of existing SOC, could be detected with reasonable sample sizes and good statistical power. The smallest difference in SOC inventories that can be detected, and only with exceedingly large sample sizes, is {approx}2 to 3%. These measurement limitations have implications for monitoring and verification of proposals to ameliorate increasing global atmospheric CO{sub 2} concentrations by sequestering C in soils.« less
A single test for rejecting the null hypothesis in subgroups and in the overall sample.
Lin, Yunzhi; Zhou, Kefei; Ganju, Jitendra
2017-01-01
In clinical trials, some patient subgroups are likely to demonstrate larger effect sizes than other subgroups. For example, the effect size, or informally the benefit with treatment, is often greater in patients with a moderate condition of a disease than in those with a mild condition. A limitation of the usual method of analysis is that it does not incorporate this ordering of effect size by patient subgroup. We propose a test statistic which supplements the conventional test by including this information and simultaneously tests the null hypothesis in pre-specified subgroups and in the overall sample. It results in more power than the conventional test when the differences in effect sizes across subgroups are at least moderately large; otherwise it loses power. The method involves combining p-values from models fit to pre-specified subgroups and the overall sample in a manner that assigns greater weight to subgroups in which a larger effect size is expected. Results are presented for randomized trials with two and three subgroups.
Influences of Co doping on the structural and optical properties of ZnO nanostructured
NASA Astrophysics Data System (ADS)
Majeed Khan, M. A.; Wasi Khan, M.; Alhoshan, Mansour; Alsalhi, M. S.; Aldwayyan, A. S.
2010-07-01
Pure and Co-doped ZnO nanostructured samples have been synthesized by a chemical route. We have studied the structural and optical properties of the samples by using X-ray diffraction (XRD), field-emission scanning electron microscopy (FESEM), field-emission transmission electron microscope (FETEM), energy-dispersive X-ray (EDX) analysis and UV-VIS spectroscopy. The XRD patterns show that all the samples are hexagonal wurtzite structures. Changes in crystallite size due to mechanical activation were also determined from X-ray measurements. These results were correlated with changes in particle size followed by SEM and TEM. The average crystallite sizes obtained from XRD were between 20 to 25 nm. The TEM images showed the average particle size of undoped ZnO nanostructure was about 20 nm whereas the smallest average grain size at 3% Co was about 15 nm. Optical parameters such as absorption coefficient ( α), energy band gap ( E g ), the refractive index ( n), and dielectric constants ( σ) have been determined using different methods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilmour, M.I.; McGee, J.; Duvall, R.M.
2007-07-01
Hundreds of epidemiological studies have shown that exposure to ambient particulate matter (PM) is associated with dose-dependent increases in morbidity and mortality. While early reports focused on PM less than 10 {mu}m (PM10), numerous studies have since shown that the effects can occur with PM stratified into ultrafine (UF), fine (FI), and coarse (CO) size modes despite the fact that these materials differ significantly in both evolution and chemistry. Furthermore the chemical makeup of these different size fractions can vary tremendously depending on location, meteorology, and source profile. For this reason, high-volume three-stage particle impactors with the capacity to collectmore » UF, FI, and CO particles were deployed to four different locations in the United States (Seattle, WA; Salt Lake City, UT; Sterling Forest and South Bronx, NY), and weekly samples were collected for 1 mo in each place. The particles were extracted, assayed for a standardized battery of chemical components, and instilled into mouse lungs (female BALB/c) at doses of 25 and 100 {mu}g. Eighteen hours later animals were euthanized and parameters of injury and inflammation were monitored in the bronchoalveolar lavage fluid and plasma. Of the four locations, the South Bronx coarse fraction was the most potent sample in both pulmonary and systemic biomarkers. Receptor source modeling on the PM2.5 samples showed that the South Bronx sample was heavily influenced by emissions from coal fired power plants (31%) and mobile sources (22%). Further studies will assess how source profiles correlate with the observed effects for all locations and size fractions.« less
Jalava, Pasi I; Salonen, Raimo O; Hälinen, Arja I; Penttinen, Piia; Pennanen, Arto S; Sillanpää, Markus; Sandell, Erik; Hillamo, Risto; Hirvonen, Maija-Riitta
2006-09-15
The impact of long-range transport (LRT) episodes of wildfire smoke on the inflammogenic and cytotoxic activity of urban air particles was investigated in the mouse RAW 264.7 macrophages. The particles were sampled in four size ranges using a modified Harvard high-volume cascade impactor, and the samples were chemically characterized for identification of different emission sources. The particulate mass concentration in the accumulation size range (PM(1-0.2)) was highly increased during two LRT episodes, but the contents of total and genotoxic polycyclic aromatic hydrocarbons (PAH) in collected particulate samples were only 10-25% of those in the seasonal average sample. The ability of coarse (PM(10-2.5)), intermodal size range (PM(2.5-1)), PM(1-0.2) and ultrafine (PM(0.2)) particles to cause cytokine production (TNFalpha, IL-6, MIP-2) reduced along with smaller particle size, but the size range had a much smaller impact on induced nitric oxide (NO) production and cytotoxicity or apoptosis. The aerosol particles collected during LRT episodes had a substantially lower activity in cytokine production than the corresponding particles of the seasonal average period, which is suggested to be due to chemical transformation of the organic fraction during aging. However, the episode events were associated with enhanced inflammogenic and cytotoxic activities per inhaled cubic meter of air due to the greatly increased particulate mass concentration in the accumulation size range, which may have public health implications.
Tan, Lingzhao; Fan, Chunyu; Zhang, Chunyu; von Gadow, Klaus; Fan, Xiuhua
2017-12-01
This study aims to establish a relationship between the sampling scale and tree species beta diversity temperate forests and to identify the underlying causes of beta diversity at different sampling scales. The data were obtained from three large observational study areas in the Changbai mountain region in northeastern China. All trees with a dbh ≥1 cm were stem-mapped and measured. The beta diversity was calculated for four different grain sizes, and the associated variances were partitioned into components explained by environmental and spatial variables to determine the contributions of environmental filtering and dispersal limitation to beta diversity. The results showed that both beta diversity and the causes of beta diversity were dependent on the sampling scale. Beta diversity decreased with increasing scales. The best-explained beta diversity variation was up to about 60% which was discovered in the secondary conifer and broad-leaved mixed forest (CBF) study area at the 40 × 40 m scale. The variation partitioning result indicated that environmental filtering showed greater effects at bigger grain sizes, while dispersal limitation was found to be more important at smaller grain sizes. What is more, the result showed an increasing explanatory ability of environmental effects with increasing sampling grains but no clearly trend of spatial effects. The study emphasized that the underlying causes of beta diversity variation may be quite different within the same region depending on varying sampling scales. Therefore, scale effects should be taken into account in future studies on beta diversity, which is critical in identifying different relative importance of spatial and environmental drivers on species composition variation.
Naltrexone and Cognitive Behavioral Therapy for the Treatment of Alcohol Dependence
Baros, AM; Latham, PK; Anton, RF
2008-01-01
Background Sex differences in regards to pharmacotherapy for alcoholism is a topic of concern following publications suggesting naltrexone, one of the longest approved treatments of alcoholism, is not as effective in women as in men. This study was conducted by combining two randomized placebo controlled clinical trials utilizing similar methodologies and personnel in which the data was amalgamated to evaluate sex effects in a reasonable sized sample. Methods 211 alcoholics (57 female; 154 male) were randomized to the naltrexone/CBT or placebo/CBT arm of the two clinical trials analyzed. Baseline variables were examined for differences between sex and treatment groups via analysis of variance (ANOVA) for continuous variable or chi-square test for categorical variables. All initial outcome analysis was conducted under an intent-to-treat analysis plan. Effect sizes for naltrexone over placebo were determined by Cohen’s D (d). Results The effect size of naltrexone over placebo for the following outcome variables was similar in men and women (%days abstinent (PDA) d=0.36, %heavy drinking days (PHDD) d=0.36 and total standard drinks (TSD) d=0.36). Only for men were the differences significant secondary to the larger sample size (PDA p=0.03; PHDD p=0.03; TSD p=0.04). There were a few variables (GGT at wk-12 change from baseline to week-12: men d=0.36, p=0.05; women d=0.20, p=0.45 and drinks per drinking day: men d=0.36, p=0.05; women d=0.28, p=0.34) where the naltrexone effect size for men was greater than women. In women, naltrexone tended to increase continuous abstinent days before a first drink (women d-0.46, p=0.09; men d=0.00, p=0.44). Conclusions The effect size of naltrexone over placebo appeared similar in women and men in our hands suggesting the findings of sex differences in naltrexone response might have to do with sample size and/or endpoint drinking variables rather than any inherent pharmacological or biological differences in response. PMID:18336635
Creep of quartz by dislocation and grain boundary processes
NASA Astrophysics Data System (ADS)
Fukuda, J. I.; Holyoke, C. W., III; Kronenberg, A. K.
2015-12-01
Wet polycrystalline quartz aggregates deformed at temperatures T of 600°-900°C and strain rates of 10-4-10-6 s-1 at a confining pressure Pc of 1.5 GPa exhibit plasticity at low T, governed by dislocation glide and limited recovery, and grain size-sensitive creep at high T, governed by diffusion and sliding at grain boundaries. Quartz aggregates were HIP-synthesized, subjecting natural milky quartz powder to T=900°C and Pc=1.5 GPa, and grain sizes (2 to 25 mm) were varied by annealing at these conditions for up to 10 days. Infrared absorption spectra exhibit a broad OH band at 3400 cm-1 due to molecular water inclusions with a calculated OH content (~4000 ppm, H/106Si) that is unchanged by deformation. Rate-stepping experiments reveal different stress-strain rate functions at different temperatures and grain sizes, which correspond to differing stress-temperature sensitivities. At 600-700°C and grain sizes of 5-10 mm, flow law parameters compare favorably with those for basal plasticity and dislocation creep of wet quartzites (effective stress exponents n of 3 to 6 and activation enthalpy H* ~150 kJ/mol). Deformed samples show undulatory extinction, limited recrystallization, and c-axis maxima parallel to the shortening direction. Similarly fine-grained samples deformed at 800°-900°C exhibit flow parameters n=1.3-2.0 and H*=135-200 kJ/mol corresponding to grain size-sensitive Newtonian creep. Deformed samples show some undulatory extinction and grain sizes change by recrystallization; however, grain boundary deformation processes are indicated by the low value of n. Our experimental results for grain size-sensitive creep can be compared with models of grain boundary diffusion and grain boundary sliding using measured rates of silicon grain boundary diffusion. While many quartz mylonites show microstructural and textural evidence for dislocation creep, results for grain size-sensitive creep may apply to very fine-grained (<10 mm) quartz mylonites.
Gebler, J.B.
2004-01-01
The related topics of spatial variability of aquatic invertebrate community metrics, implications of spatial patterns of metric values to distributions of aquatic invertebrate communities, and ramifications of natural variability to the detection of human perturbations were investigated. Four metrics commonly used for stream assessment were computed for 9 stream reaches within a fairly homogeneous, minimally impaired stream segment of the San Pedro River, Arizona. Metric variability was assessed for differing sampling scenarios using simple permutation procedures. Spatial patterns of metric values suggest that aquatic invertebrate communities are patchily distributed on subsegment and segment scales, which causes metric variability. Wide ranges of metric values resulted in wide ranges of metric coefficients of variation (CVs) and minimum detectable differences (MDDs), and both CVs and MDDs often increased as sample size (number of reaches) increased, suggesting that any particular set of sampling reaches could yield misleading estimates of population parameters and effects that can be detected. Mean metric variabilities were substantial, with the result that only fairly large differences in metrics would be declared significant at ?? = 0.05 and ?? = 0.20. The number of reaches required to obtain MDDs of 10% and 20% varied with significance level and power, and differed for different metrics, but were generally large, ranging into tens and hundreds of reaches. Study results suggest that metric values from one or a small number of stream reach(es) may not be adequate to represent a stream segment, depending on effect sizes of interest, and that larger sample sizes are necessary to obtain reasonable estimates of metrics and sample statistics. For bioassessment to progress, spatial variability may need to be investigated in many systems and should be considered when designing studies and interpreting data.
Vogel, J.R.; Brown, G.O.
2003-01-01
Semivariograms of samples of Culebra Dolomite have been determined at two different resolutions for gamma ray computed tomography images. By fitting models to semivariograms, small-scale and large-scale correlation lengths are determined for four samples. Different semivariogram parameters were found for adjacent cores at both resolutions. Relative elementary volume (REV) concepts are related to the stationarity of the sample. A scale disparity factor is defined and is used to determine sample size required for ergodic stationarity with a specified correlation length. This allows for comparison of geostatistical measures and representative elementary volumes. The modifiable areal unit problem is also addressed and used to determine resolution effects on correlation lengths. By changing resolution, a range of correlation lengths can be determined for the same sample. Comparison of voxel volume to the best-fit model correlation length of a single sample at different resolutions reveals a linear scaling effect. Using this relationship, the range of the point value semivariogram is determined. This is the range approached as the voxel size goes to zero. Finally, these results are compared to the regularization theory of point variables for borehole cores and are found to be a better fit for predicting the volume-averaged range.
Adequacy of laser diffraction for soil particle size analysis
Fisher, Peter; Aumann, Colin; Chia, Kohleth; O'Halloran, Nick; Chandra, Subhash
2017-01-01
Sedimentation has been a standard methodology for particle size analysis since the early 1900s. In recent years laser diffraction is beginning to replace sedimentation as the prefered technique in some industries, such as marine sediment analysis. However, for the particle size analysis of soils, which have a diverse range of both particle size and shape, laser diffraction still requires evaluation of its reliability. In this study, the sedimentation based sieve plummet balance method and the laser diffraction method were used to measure the particle size distribution of 22 soil samples representing four contrasting Australian Soil Orders. Initially, a precise wet riffling methodology was developed capable of obtaining representative samples within the recommended obscuration range for laser diffraction. It was found that repeatable results were obtained even if measurements were made at the extreme ends of the manufacturer’s recommended obscuration range. Results from statistical analysis suggested that the use of sample pretreatment to remove soil organic carbon (and possible traces of calcium-carbonate content) made minor differences to the laser diffraction particle size distributions compared to no pretreatment. These differences were found to be marginally statistically significant in the Podosol topsoil and Vertosol subsoil. There are well known reasons why sedimentation methods may be considered to ‘overestimate’ plate-like clay particles, while laser diffraction will ‘underestimate’ the proportion of clay particles. In this study we used Lin’s concordance correlation coefficient to determine the equivalence of laser diffraction and sieve plummet balance results. The results suggested that the laser diffraction equivalent thresholds corresponding to the sieve plummet balance cumulative particle sizes of < 2 μm, < 20 μm, and < 200 μm, were < 9 μm, < 26 μm, < 275 μm respectively. The many advantages of laser diffraction for soil particle size analysis, and the empirical results of this study, suggest that deployment of laser diffraction as a standard test procedure can provide reliable results, provided consistent sample preparation is used. PMID:28472043
Human body mass estimation: a comparison of "morphometric" and "mechanical" methods.
Auerbach, Benjamin M; Ruff, Christopher B
2004-12-01
In the past, body mass was reconstructed from hominin skeletal remains using both "mechanical" methods which rely on the support of body mass by weight-bearing skeletal elements, and "morphometric" methods which reconstruct body mass through direct assessment of body size and shape. A previous comparison of two such techniques, using femoral head breadth (mechanical) and stature and bi-iliac breadth (morphometric), indicated a good general correspondence between them (Ruff et al. [1997] Nature 387:173-176). However, the two techniques were never systematically compared across a large group of modern humans of diverse body form. This study incorporates skeletal measures taken from 1,173 Holocene adult individuals, representing diverse geographic origins, body sizes, and body shapes. Femoral head breadth, bi-iliac breadth (after pelvic rearticulation), and long bone lengths were measured on each individual. Statures were estimated from long bone lengths using appropriate reference samples. Body masses were calculated using three available femoral head breadth (FH) formulae and the stature/bi-iliac breadth (STBIB) formula, and compared. All methods yielded similar results. Correlations between FH estimates and STBIB estimates are 0.74-0.81. Slight differences in results between the three FH estimates can be attributed to sampling differences in the original reference samples, and in particular, the body-size ranges included in those samples. There is no evidence for systematic differences in results due to differences in body proportions. Since the STBIB method was validated on other samples, and the FH methods produced similar estimates, this argues that either may be applied to skeletal remains with some confidence. 2004 Wiley-Liss, Inc.
Ramezani, Habib; Holm, Sören; Allard, Anna; Ståhl, Göran
2010-05-01
Environmental monitoring of landscapes is of increasing interest. To quantify landscape patterns, a number of metrics are used, of which Shannon's diversity, edge length, and density are studied here. As an alternative to complete mapping, point sampling was applied to estimate the metrics for already mapped landscapes selected from the National Inventory of Landscapes in Sweden (NILS). Monte-Carlo simulation was applied to study the performance of different designs. Random and systematic samplings were applied for four sample sizes and five buffer widths. The latter feature was relevant for edge length, since length was estimated through the number of points falling in buffer areas around edges. In addition, two landscape complexities were tested by applying two classification schemes with seven or 20 land cover classes to the NILS data. As expected, the root mean square error (RMSE) of the estimators decreased with increasing sample size. The estimators of both metrics were slightly biased, but the bias of Shannon's diversity estimator was shown to decrease when sample size increased. In the edge length case, an increasing buffer width resulted in larger bias due to the increased impact of boundary conditions; this effect was shown to be independent of sample size. However, we also developed adjusted estimators that eliminate the bias of the edge length estimator. The rates of decrease of RMSE with increasing sample size and buffer width were quantified by a regression model. Finally, indicative cost-accuracy relationships were derived showing that point sampling could be a competitive alternative to complete wall-to-wall mapping.
Foundational Principles for Large-Scale Inference: Illustrations Through Correlation Mining
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hero, Alfred O.; Rajaratnam, Bala
When can reliable inference be drawn in the ‘‘Big Data’’ context? This article presents a framework for answering this fundamental question in the context of correlation mining, with implications for general large-scale inference. In large-scale data applications like genomics, connectomics, and eco-informatics, the data set is often variable rich but sample starved: a regime where the number n of acquired samples (statistical replicates) is far fewer than the number p of observed variables (genes, neurons, voxels, or chemical constituents). Much of recent work has focused on understanding the computational complexity of proposed methods for ‘‘Big Data.’’ Sample complexity, however, hasmore » received relatively less attention, especially in the setting when the sample size n is fixed, and the dimension p grows without bound. To address this gap, we develop a unified statistical framework that explicitly quantifies the sample complexity of various inferential tasks. Sampling regimes can be divided into several categories: 1) the classical asymptotic regime where the variable dimension is fixed and the sample size goes to infinity; 2) the mixed asymptotic regime where both variable dimension and sample size go to infinity at comparable rates; and 3) the purely high-dimensional asymptotic regime where the variable dimension goes to infinity and the sample size is fixed. Each regime has its niche but only the latter regime applies to exa-scale data dimension. We illustrate this high-dimensional framework for the problem of correlation mining, where it is the matrix of pairwise and partial correlations among the variables that are of interest. Correlation mining arises in numerous applications and subsumes the regression context as a special case. We demonstrate various regimes of correlation mining based on the unifying perspective of high-dimensional learning rates and sample complexity for different structured covariance models and different inference tasks.« less
Foundational Principles for Large-Scale Inference: Illustrations Through Correlation Mining
Hero, Alfred O.; Rajaratnam, Bala
2015-01-01
When can reliable inference be drawn in fue “Big Data” context? This paper presents a framework for answering this fundamental question in the context of correlation mining, wifu implications for general large scale inference. In large scale data applications like genomics, connectomics, and eco-informatics fue dataset is often variable-rich but sample-starved: a regime where the number n of acquired samples (statistical replicates) is far fewer than fue number p of observed variables (genes, neurons, voxels, or chemical constituents). Much of recent work has focused on understanding the computational complexity of proposed methods for “Big Data”. Sample complexity however has received relatively less attention, especially in the setting when the sample size n is fixed, and the dimension p grows without bound. To address fuis gap, we develop a unified statistical framework that explicitly quantifies the sample complexity of various inferential tasks. Sampling regimes can be divided into several categories: 1) the classical asymptotic regime where fue variable dimension is fixed and fue sample size goes to infinity; 2) the mixed asymptotic regime where both variable dimension and sample size go to infinity at comparable rates; 3) the purely high dimensional asymptotic regime where the variable dimension goes to infinity and the sample size is fixed. Each regime has its niche but only the latter regime applies to exa cale data dimension. We illustrate this high dimensional framework for the problem of correlation mining, where it is the matrix of pairwise and partial correlations among the variables fua t are of interest. Correlation mining arises in numerous applications and subsumes the regression context as a special case. we demonstrate various regimes of correlation mining based on the unifying perspective of high dimensional learning rates and sample complexity for different structured covariance models and different inference tasks. PMID:27087700
Foundational Principles for Large-Scale Inference: Illustrations Through Correlation Mining
Hero, Alfred O.; Rajaratnam, Bala
2015-12-09
When can reliable inference be drawn in the ‘‘Big Data’’ context? This article presents a framework for answering this fundamental question in the context of correlation mining, with implications for general large-scale inference. In large-scale data applications like genomics, connectomics, and eco-informatics, the data set is often variable rich but sample starved: a regime where the number n of acquired samples (statistical replicates) is far fewer than the number p of observed variables (genes, neurons, voxels, or chemical constituents). Much of recent work has focused on understanding the computational complexity of proposed methods for ‘‘Big Data.’’ Sample complexity, however, hasmore » received relatively less attention, especially in the setting when the sample size n is fixed, and the dimension p grows without bound. To address this gap, we develop a unified statistical framework that explicitly quantifies the sample complexity of various inferential tasks. Sampling regimes can be divided into several categories: 1) the classical asymptotic regime where the variable dimension is fixed and the sample size goes to infinity; 2) the mixed asymptotic regime where both variable dimension and sample size go to infinity at comparable rates; and 3) the purely high-dimensional asymptotic regime where the variable dimension goes to infinity and the sample size is fixed. Each regime has its niche but only the latter regime applies to exa-scale data dimension. We illustrate this high-dimensional framework for the problem of correlation mining, where it is the matrix of pairwise and partial correlations among the variables that are of interest. Correlation mining arises in numerous applications and subsumes the regression context as a special case. We demonstrate various regimes of correlation mining based on the unifying perspective of high-dimensional learning rates and sample complexity for different structured covariance models and different inference tasks.« less
Melby-Lervåg, Monica; Lervåg, Arne
2014-03-01
We report a systematic meta-analytic review of studies comparing reading comprehension and its underlying components (language comprehension, decoding, and phonological awareness) in first- and second-language learners. The review included 82 studies, and 576 effect sizes were calculated for reading comprehension and underlying components. Key findings were that, compared to first-language learners, second-language learners display a medium-sized deficit in reading comprehension (pooled effect size d = -0.62), a large deficit in language comprehension (pooled effect size d = -1.12), but only small differences in phonological awareness (pooled effect size d = -0.08) and decoding (pooled effect size d = -0.12). A moderator analysis showed that characteristics related to the type of reading comprehension test reliably explained the variation in the differences in reading comprehension between first- and second-language learners. For language comprehension, studies of samples from low socioeconomic backgrounds and samples where only the first language was used at home generated the largest group differences in favor of first-language learners. Test characteristics and study origin reliably contributed to the variations between the studies of language comprehension. For decoding, Canadian studies showed group differences in favor of second-language learners, whereas the opposite was the case for U.S. studies. Regarding implications, unless specific decoding problems are detected, interventions that aim to ameliorate reading comprehension problems among second-language learners should focus on language comprehension skills.
Spatial Distribution of Elemental Concentrations in Street Dust of Hanoi, Vietnam.
Phi, Thai Ha; Chinh, Pham Minh; Hung, Nguyen The; Ly, Luong Thi Mai; Thai, Phong K
2017-02-01
Street dust samples were collected at 163 locations across four different zones of Hanoi, Vietnam, covering different traffic and population densities. Samples were sieved into three fractions of different particle sizes and analyzed for elemental concentrations (K, Ca, Mn, Fe, Zn, Pb) using an X-ray fluorescence (XRF) instrument. The metal concentrations in street dust were compared among different sampling zones and with samples from background to evaluate the degree of pollution. The smallest size particle fraction (diameter <75 μm) contained higher concentrations of metals than the coarser ones (diameters = 75-180 and >180 μm). While concentrations of metals like Ca and Fe are spatially similar, concentrations of Pb and Zn in street dust varied between different zones, with the highest concentrations observed in dust from the downtown area, and lowest levels in the new suburb areas. Overall, compared to studies from cities in other countries, the mean concentration of Pb in street dust in Hanoi was relatively low, suggesting a lower risk to human health due to inhalation or ingestion of Pb-containing dust particles than in cities where Pb concentrations were several times higher.
Portillo, M C; Gonzalez, J M
2008-08-01
Molecular fingerprints of microbial communities are a common method for the analysis and comparison of environmental samples. The significance of differences between microbial community fingerprints was analyzed considering the presence of different phylotypes and their relative abundance. A method is proposed by simulating coverage of the analyzed communities as a function of sampling size applying a Cramér-von Mises statistic. Comparisons were performed by a Monte Carlo testing procedure. As an example, this procedure was used to compare several sediment samples from freshwater ponds using a relative quantitative PCR-DGGE profiling technique. The method was able to discriminate among different samples based on their molecular fingerprints, and confirmed the lack of differences between aliquots from a single sample.
Shirazi, Mohammadali; Reddy Geedipally, Srinivas; Lord, Dominique
2017-01-01
Severity distribution functions (SDFs) are used in highway safety to estimate the severity of crashes and conduct different types of safety evaluations and analyses. Developing a new SDF is a difficult task and demands significant time and resources. To simplify the process, the Highway Safety Manual (HSM) has started to document SDF models for different types of facilities. As such, SDF models have recently been introduced for freeway and ramps in HSM addendum. However, since these functions or models are fitted and validated using data from a few selected number of states, they are required to be calibrated to the local conditions when applied to a new jurisdiction. The HSM provides a methodology to calibrate the models through a scalar calibration factor. However, the proposed methodology to calibrate SDFs was never validated through research. Furthermore, there are no concrete guidelines to select a reliable sample size. Using extensive simulation, this paper documents an analysis that examined the bias between the 'true' and 'estimated' calibration factors. It was indicated that as the value of the true calibration factor deviates further away from '1', more bias is observed between the 'true' and 'estimated' calibration factors. In addition, simulation studies were performed to determine the calibration sample size for various conditions. It was found that, as the average of the coefficient of variation (CV) of the 'KAB' and 'C' crashes increases, the analyst needs to collect a larger sample size to calibrate SDF models. Taking this observation into account, sample-size guidelines are proposed based on the average CV of crash severities that are used for the calibration process. Copyright © 2016 Elsevier Ltd. All rights reserved.
Heinicke, Grant; Matthews, Frank; Schwartz, Joseph B
2005-01-01
Drugs layering experiments were performed in a fluid bed fitted with a rotor granulator insert using diltiazem as a model drug. The drug was applied in various quantities to sugar spheres of different mesh sizes to give a series of drug-layered sugar spheres (cores) of different potency, size, and weight per particle. The drug presence lowered the bulk density of the cores in proportion to the quantity of added drug. Polymer coating of each core lot was performed in a fluid bed fitted with a Wurster insert. A series of polymer-coated cores (pellets) was removed from each coating experiment. The mean diameter of each core and each pellet sample was determined by image analysis. The rate of change of diameter on polymer addition was determined for each starting size of core and compared to calculated values. The core diameter was displaced from the line of best fit through the pellet diameter data. Cores of different potency with the same size distribution were made by layering increasing quantities of drug onto sugar spheres of decreasing mesh size. Equal quantities of polymer were applied to the same-sized core lots and coat thickness was measured. Weight/weight calculations predict equal coat thickness under these conditions, but measurable differences were found. Simple corrections to core charge weight in the Wurster insert were successfully used to manufacture pellets having the same coat thickness. The sensitivity of the image analysis technique in measuring particle size distributions (PSDs) was demonstrated by measuring a displacement in PSD after addition of 0.5% w/w talc to a pellet sample.
Shahbi, M; Rajabpour, A
2017-08-01
Phthorimaea operculella Zeller is an important pest of potato in Iran. Spatial distribution and fixed-precision sequential sampling for population estimation of the pest on two potato cultivars, Arinda ® and Sante ® , were studied in two separate potato fields during two growing seasons (2013-2014 and 2014-2015). Spatial distribution was investigated by Taylor's power law and Iwao's patchiness. Results showed that the spatial distribution of eggs and larvae was random. In contrast to Iwao's patchiness, Taylor's power law provided a highly significant relationship between variance and mean density. Therefore, fixed-precision sequential sampling plan was developed by Green's model at two precision levels of 0.25 and 0.1. The optimum sample size on Arinda ® and Sante ® cultivars at precision level of 0.25 ranged from 151 to 813 and 149 to 802 leaves, respectively. At 0.1 precision level, the sample sizes varied from 5083 to 1054 and 5100 to 1050 leaves for Arinda ® and Sante ® cultivars, respectively. Therefore, the optimum sample sizes for the cultivars, with different resistance levels, were not significantly different. According to the calculated stop lines, the sampling must be continued until cumulative number of eggs + larvae reached to 15-16 or 96-101 individuals at precision levels of 0.25 or 0.1, respectively. The performance of the sampling plan was validated by resampling analysis using resampling for validation of sampling plans software. The sampling plant provided in this study can be used to obtain a rapid estimate of the pest density with minimal effort.
Industrial Application of Valuable Materials Generated from PLK Rock-A Bauxite Mining Waste
NASA Astrophysics Data System (ADS)
Swain, Ranjita; Routray, Sunita; Mohapatra, Abhisek; Ranjan Patra, Biswa
2018-03-01
PLK rock classified in to two products after a selective grinding to a particular size fraction. PLK rocks ground to below 45-micron size which is followed by a classifier i.e. hydrocyclone. The ground product classified in to different sizes of apex and vortex finder. The pressure gauge was attached for the measurement of the pressure. The production of fines is also increasing with increase in the vortex finder diameter. In order to increase in the feed capacity of the hydrocyclone, the vortex finder 11.1 mm diameter and the spigot diameter 8.0 mm has been considered as the best optimum condition for recovery of fines from PLK rock sample. The overflow sample contains 5.39% iron oxide (Fe2O3) with 0.97% of TiO2 and underflow sample contains 1.87% Fe2O3 with 2.39% of TiO2. The cut point or separation size of overflow sample is 25 μm. The efficiency of separation, or the so-called imperfection I, is at 6 μm size. In this study, the iron oxide content in underflow sample is less than 2% which is suitable for making of refractory application. The overflow sample is very fine which can also be a raw material for ceramic industry as well as a cosmetic product.
Catch of channel catfish with tandem-set hoop nets and gill nets in lentic systems of Nebraska
Richters, Lindsey K.; Pope, Kevin L.
2011-01-01
Twenty-six Nebraska water bodies representing two ecosystem types (small standing waters and large standing waters) were surveyed during 2008 and 2009 with tandem-set hoop nets and experimental gill nets to determine if similar trends existed in catch rates and size structures of channel catfish Ictalurus punctatus captured with these gears. Gear efficiency was assessed as the number of sets (nets) that would be required to capture 100 channel catfish given observed catch per unit effort (CPUE). Efficiency of gill nets was not correlated with efficiency of hoop nets for capturing channel catfish. Small sample sizes prohibited estimation of proportional size distributions in most surveys; in the four surveys for which sample size was sufficient to quantify length-frequency distributions of captured channel catfish, distributions differed between gears. The CPUE of channel catfish did not differ between small and large water bodies for either gear. While catch rates of hoop nets were lower than rates recorded in previous studies, this gear was more efficient than gill nets at capturing channel catfish. However, comparisons of size structure between gears may be problematic.
Zhang, Ming; Wang, Ai-Juan; Li, Jun-Ming; Song, Na
2017-10-01
Stearic acid (Sa) was used to modify the surface properties of hydroxyapatite (HAp) in different solvents (water, ethanol or dichloromethane(CH 2 Cl 2 )). Effect of different solvents on the properties of HAp particles (activation ratio, grafting ratio, chemical properties), emulsion properties (emulsion stability, emulsion type, droplet morphology) as well as the cured materials (morphology, average pore size) were studied. FT-IR and XPS results confirmed the interaction occurred between stearic acid and HAp particles. Stable O/W and W/O type Pickering emulsions were prepared using unmodified and Sa modified HAp nanoparticles respectively, which indicated a catastrophic inversion of the Pickering emulsion happened possibly because of the enhanced hydrophobicity of HAp particles after surface modification. Porous materials with different structures and pore sizes were obtained using Pickering emulsion as the template via in situ evaporation solvent method. The results indicated the microstructures of cured samples are different form each other when HAp was surface modified in different solvents. HAp particles fabricated using ethanol as solvent has higher activation ratio and grafting ratio. Pickering emulsion with higher stability and cured porous materials with uniform morphology were obtained compared with samples prepared using water and CH 2 Cl 2 as solvents. In conclusion, surface modification of HAp in different solvents played a very important role for its stabilized Pickering emulsion as well as the microstructure of cured samples. It is better to use ethanol as the solvent for Sa modified HAp particles, which could increase the stability of Pickering emulsion and obtain cured samples with uniform pore size. Copyright © 2017 Elsevier B.V. All rights reserved.
Optimizing Sampling Efficiency for Biomass Estimation Across NEON Domains
NASA Astrophysics Data System (ADS)
Abercrombie, H. H.; Meier, C. L.; Spencer, J. J.
2013-12-01
Over the course of 30 years, the National Ecological Observatory Network (NEON) will measure plant biomass and productivity across the U.S. to enable an understanding of terrestrial carbon cycle responses to ecosystem change drivers. Over the next several years, prior to operational sampling at a site, NEON will complete construction and characterization phases during which a limited amount of sampling will be done at each site to inform sampling designs, and guide standardization of data collection across all sites. Sampling biomass in 60+ sites distributed among 20 different eco-climatic domains poses major logistical and budgetary challenges. Traditional biomass sampling methods such as clip harvesting and direct measurements of Leaf Area Index (LAI) involve collecting and processing plant samples, and are time and labor intensive. Possible alternatives include using indirect sampling methods for estimating LAI such as digital hemispherical photography (DHP) or using a LI-COR 2200 Plant Canopy Analyzer. These LAI estimations can then be used as a proxy for biomass. The biomass estimates calculated can then inform the clip harvest sampling design during NEON operations, optimizing both sample size and number so that standardized uncertainty limits can be achieved with a minimum amount of sampling effort. In 2011, LAI and clip harvest data were collected from co-located sampling points at the Central Plains Experimental Range located in northern Colorado, a short grass steppe ecosystem that is the NEON Domain 10 core site. LAI was measured with a LI-COR 2200 Plant Canopy Analyzer. The layout of the sampling design included four, 300 meter transects, with clip harvests plots spaced every 50m, and LAI sub-transects spaced every 10m. LAI was measured at four points along 6m sub-transects running perpendicular to the 300m transect. Clip harvest plots were co-located 4m from corresponding LAI transects, and had dimensions of 0.1m by 2m. We conducted regression analyses with LAI and clip harvest data to determine whether LAI can be used as a suitable proxy for aboveground standing biomass. We also compared optimal sample sizes derived from LAI data, and clip-harvest data from two different size clip harvest areas (0.1m by 1m vs. 0.1m by 2m). Sample sizes were calculated in order to estimate the mean to within a standardized level of uncertainty that will be used to guide sampling effort across all vegetation types (i.e. estimated within × 10% with 95% confidence). Finally, we employed a Semivariogram approach to determine optimal sample size and spacing.
The effectiveness of increased apical enlargement in reducing intracanal bacteria.
Card, Steven J; Sigurdsson, Asgeir; Orstavik, Dag; Trope, Martin
2002-11-01
It has been suggested that the apical portion of a root canal is not adequately disinfected by typical instrumentation regimens. The purpose of this study was to determine whether instrumentation to sizes larger than typically used would more effectively remove culturable bacteria from the canal. Forty patients with clinical and radiographic evidence of apical periodontitis were recruited from the endodontic clinic. Mandibular cuspids (n = 2), bicuspids (n = 11), and molars (mesial roots) (n = 27) were selected for the study. Bacterial sampling was performed upon access and after each of two consecutive instrumentations. The first instrumentation utilized 1% NaOCI and 0.04 taper ProFile rotary files. The cuspid and bicuspid canals were instrumented to a #8 size and the molar canals to a #7 size. The second instrumentation utilized LightSpeed files and 1% NaOCl irrigation for further enlargement of the apical third. Typically, molars were instrumented to size 60 and cuspid/bicuspid canals to size 80. Our findings show that 100% of the cuspid/bicuspid canals and 81.5% of the molar canals were rendered bacteria-free after the first instrumentation sizes. The molar results improved to 89% after the second instrumentation. Of the (59.3%) molar mesial canals without a clinically detectable communication, 93% were rendered bacteria-free with the first instrumentation. Using a Wilcoxon rank sum test, statistically significant differences (p < 0.0001) were found between the initial sample and the samples after the first and second instrumentations. The differences between the samples that followed the two instrumentation regimens were not significant (p = 0.0617). It is concluded that simple root canal systems (without multiple canal communications) may be rendered bacteria-free when preparation of this type is utilized.
Ghrefat, H.A.; Goodell, P.C.; Hubbard, B.E.; Langford, R.P.; Aldouri, R.E.
2007-01-01
Visible and Near-Infrared (VNIR) through Short Wavelength Infrared (SWIR) (0.4-2.5????m) AVIRIS data, along with laboratory spectral measurements and analyses of field samples, were used to characterize grain size variations in aeolian gypsum deposits across barchan-transverse, parabolic, and barchan dunes at White Sands, New Mexico, USA. All field samples contained a mineralogy of ?????100% gypsum. In order to document grain size variations at White Sands, surficial gypsum samples were collected along three Transects parallel to the prevailing downwind direction. Grain size analyses were carried out on the samples by sieving them into seven size fractions ranging from 45 to 621????m, which were subjected to spectral measurements. Absorption band depths of the size fractions were determined after applying an automated continuum-removal procedure to each spectrum. Then, the relationship between absorption band depth and gypsum size fraction was established using a linear regression. Three software processing steps were carried out to measure the grain size variations of gypsum in the Dune Area using AVIRIS data. AVIRIS mapping results, field work and laboratory analysis all show that the interdune areas have lower absorption band depth values and consist of finer grained gypsum deposits. In contrast, the dune crest areas have higher absorption band depth values and consist of coarser grained gypsum deposits. Based on laboratory estimates, a representative barchan-transverse dune (Transect 1) has a mean grain size of 1.16 ??{symbol} (449????m). The error bar results show that the error ranges from - 50 to + 50????m. Mean grain size for a representative parabolic dune (Transect 2) is 1.51 ??{symbol} (352????m), and 1.52 ??{symbol} (347????m) for a representative barchan dune (Transect 3). T-test results confirm that there are differences in the grain size distributions between barchan and parabolic dunes and between interdune and dune crest areas. The t-test results also show that there are no significant differences between modeled and laboratory-measured grain size values. Hyperspectral grain size modeling can help to determine dynamic processes shaping the formation of the dunes such as wind directions, and the relative strengths of winds through time. This has implications for studying such processes on other planetary landforms that have mineralogy with unique absorption bands in VNIR-SWIR hyperspectral data. ?? 2006 Elsevier B.V. All rights reserved.
Photo series for quantifying natural forest residues: southern Cascades, northern Sierra Nevada
Kenneth S. Blonski; John L. Schramel
1981-01-01
A total of 56 photographs shows different levels of natural fuel loadings for selected size classes in seven forest types of the southern Cascade and northern Sierra-Nevada ranges. Data provided with each photo include size, weight, volumes, residue depths, and percent of ground coverage. Stand information includes sizes, weights, and volumes of the trees sampled for...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frølich, S.; Leemreize, H.; Jakus, A.
A model sample consisting of two different hydroxyapatite (hAp) powders was used as a bone phantom to investigate the extent to which X-ray diffraction tomography could map differences in hAp lattice constants and crystallite size. The diffraction data were collected at beamline 1-ID, the Advanced Photon Source, using monochromatic 65 keV X-radiation, a 25 × 25 µm pinhole beam and translation/rotation data collection. The diffraction pattern was reconstructed for each volume element (voxel) in the sample, and Rietveld refinement was used to determine the hAp lattice constants. The crystallite size for each voxel was also determined from the 00.2 hApmore » diffraction peak width. The results clearly show that differences between hAp powders could be measured with diffraction tomography.« less
Haynes, R J; Belyaeva, O N; Zhou, Y-F
2015-01-01
In order to better characterize mechanically shredded municipal green waste used for composting, five samples from different origins were separated into seven particle size fractions (>20mm, 10-20mm, 5-10mm, 2-5mm, 1-2mm, 0.5-1.0mm and <0.5mm diameter) and analyzed for organic C and nutrient content. With decreasing particle size there was a decrease in organic C content and an increase in macronutrient, micronutrient and ash content. This reflected a concentration of lignified woody material in the larger particle fractions and of green stems and leaves and soil in the smaller particle sizes. The accumulation of nutrients in the smaller sized fractions means the practice of using large particle sizes for green fuel and/or mulch does not greatly affect nutrient cycling via green waste composting. During a 100-day incubation experiment, using different particle size fractions of green waste, there was a marked increase in both cumulative CO2 evolution and mineral N accumulation with decreasing particle size. Results suggested that during composting of bulk green waste (with a high initial C/N ratio such as 50:1), mineral N accumulates because decomposition and net N immobilization in larger particles is slow while net N mineralization proceeds rapidly in the smaller (<1mm dia.) fractions. Initially, mineral N accumulated in green waste as NH4(+)-N, but over time, nitrification proceeded resulting in accumulation of NO3(-)-N. It was concluded that the nutrient content, N mineralization potential and decomposition rate of green waste differs greatly among particle size fractions and that chemical analysis of particle size fractions provides important additional information over that of a bulk sample. Copyright © 2014 Elsevier Ltd. All rights reserved.
Spiegelhalter, D J; Freedman, L S
1986-01-01
The 'textbook' approach to determining sample size in a clinical trial has some fundamental weaknesses which we discuss. We describe a new predictive method which takes account of prior clinical opinion about the treatment difference. The method adopts the point of clinical equivalence (determined by interviewing the clinical participants) as the null hypothesis. Decision rules at the end of the study are based on whether the interval estimate of the treatment difference (classical or Bayesian) includes the null hypothesis. The prior distribution is used to predict the probabilities of making the decisions to use one or other treatment or to reserve final judgement. It is recommended that sample size be chosen to control the predicted probability of the last of these decisions. An example is given from a multi-centre trial of superficial bladder cancer.
Waliszewski, Matthias W; Redlich, Ulf; Breul, Victor; Tautenhahn, Jörg
2017-04-30
The aim of this review is to present the available clinical and surrogate endpoints that may be used in future studies performed in patients with peripheral artery occlusive disease (PAOD). Importantly, we describe statistical limitations of the most commonly used endpoints and offer some guidance with respect to study design for a given sample size. The proposed endpoints may be used in studies using surgical or interventional revascularization and/or drug treatments. Considering recently published study endpoints and designs, the usefulness of these endpoints for reimbursement is evaluated. Based on these potential study endpoints and patient sample size estimates with different non-inferiority or tests for difference hypotheses, a rating relative to their corresponding reimbursement values is attempted. As regards the benefit for the patients and for the payers, walking distance and the ankle brachial index (ABI) are the most feasible endpoints in a relatively small study samples given that other non-vascular impact factors can be controlled. Angiographic endpoints such as minimal lumen diameter (MLD) do not seem useful from a reimbursement standpoint despite their intuitiveness. Other surrogate endpoints, such as transcutaneous oxygen tension measurements, have yet to be established as useful endpoints in reasonably sized studies with patients with critical limb ischemia (CLI). From a reimbursement standpoint, WD and ABI are effective endpoints for a moderate study sample size given that non-vascular confounding factors can be controlled.
Zou, Yang; Dong, Shuangzhao; Du, Yun; Li, Shengli; Wang, Yajing; Cao, Zhijun
2016-09-01
A study using four Holstein cows with ruminal cannulas was conducted to evaluate the degradability of different moisture content or particle size of maize silage and alfalfa haylage. The maize silage (MS; 20-mm length) and alfalfa haylage (AH; 40-mm length) samples were wet (wet maize silage, MSW; wet alfalfa haylage, AHW), dried (dried maize silage, MSD; dried alfalfa haylage, AHD), or ground to pass through a 2.5-mm screen (dried ground maize silage, MSG; dried ground alfalfa haylage, AHG). Samples were incubated in the rumen for 2, 6, 12, 24, 36, 48, and 72 h. Cows were fed ad libitum and allowed free access to water. High moisture content treatment of MSW expressed a lower rinsing NDF and ADF degradability at 2 h ( P < 0.05) compared with dried samples (MSD and MSG). Different moisture content and particle size had a significant impact ( P < 0.05) on the NDF degradability at 72 h, ADF degradability at 36, 48, and 72 h, and ruminally degradable ADF. All of the highest values were observed in small particle size and low moisture content AHG treatment. Based on this study, sample processing, such as drying and grinding, should be considered when evaluating nutritive values of forages.
Bacterial contamination of boar semen affects the litter size.
Maroto Martín, Luis O; Muñoz, Eduardo Cruz; De Cupere, Françoise; Van Driessche, Edilbert; Echemendia-Blanco, Dannele; Rodríguez, José M Machado; Beeckmans, Sonia
2010-07-01
One hundred and fifteen semen samples were collected from 115 different boars from two farms in Cuba. The boars belonged to five different breeds. Evaluation of the semen sample characteristics (volume, pH, colour, smell, motility of sperm cells) revealed that they meet international standards. The samples were also tested for the presence of agglutinated sperm cells and for bacterial contamination. Seventy five percent of the ejaculates were contaminated with at least one type of bacteria and E. coli was by far the major contaminant, being present in 79% of the contaminated semen samples (n=68). Other contaminating bacteria belonged to the genera Proteus (n=31), Serratia (n=31), Enterobacter (n=24), Klebsiella (n=12), Staphylococcus (n=10), Streptococcus (n=8) and Pseudomonas (n=7). Only in one sample anaerobic bacteria were detected. Pearson's analysis of the data revealed that there is a positive correlation between the presence of E. coli and sperm agglutination, and a negative correlation between sperm agglutination and litter size. One-way ANOVA and post hoc Tukey analysis of 378 litters showed that the litter size is significantly reduced when semen is used that is contaminated with spermagglutinating E. coli above a threshold value of 3.5x10(3)CFU/ml. Copyright 2010 Elsevier B.V. All rights reserved.
Vinson, M.R.; Budy, P.
2011-01-01
We compared sources of variability and cost in paired stomach content and stable isotope samples from three salmonid species collected in September 2001–2005 and describe the relative information provided by each method in terms of measuring diet overlap and food web study design. Based on diet analyses, diet overlap among brown trout, rainbow trout, and mountain whitefish was high, and we observed little variation in diets among years. In contrast, for sample sizes n ≥ 25, 95% confidence interval (CI) around mean δ15Ν and δ13C for the three target species did not overlap, and species, year, and fish size effects were significantly different, implying that these species likely consumed similar prey but in different proportions. Stable isotope processing costs were US$12 per sample, while stomach content analysis costs averaged US$25.49 ± $2.91 (95% CI) and ranged from US$1.50 for an empty stomach to US$291.50 for a sample with 2330 items. Precision in both δ15Ν and δ13C and mean diet overlap values based on stomach contents increased considerably up to a sample size of n = 10 and plateaued around n = 25, with little further increase in precision.
ERIC Educational Resources Information Center
Sengul Avsar, Asiye; Tavsancil, Ezel
2017-01-01
This study analysed polytomous items' psychometric properties according to nonparametric item response theory (NIRT) models. Thus, simulated datasets--three different test lengths (10, 20 and 30 items), three sample distributions (normal, right and left skewed) and three samples sizes (100, 250 and 500)--were generated by conducting 20…
Winter feeding success of stream trout under different streamflow and turbidity conditions
Jason L. White; Bret C. Harvey
2007-01-01
To investigate the relationship between turbidity and trout feeding success in natural systems, we sampled the stomach contents of resident rainbow trout Oncorhynchus mykiss and coastal cutthroat trout O. clarkii clarkii under different streamflow and turbidity conditions during winter in two northwestern California streams (total sample size¼161). Feeding success...
A gold nanoparticle-based immunochromatographic assay: the influence of nanoparticulate size.
Lou, Sha; Ye, Jia-ying; Li, Ke-qiang; Wu, Aiguo
2012-03-07
Four different sized gold nanoparticles (14 nm, 16 nm, 35 nm and 38 nm) were prepared to conjugate an antibody for a gold nanoparticle-based immunochromatographic assay which has many applications in both basic research and clinical diagnosis. This study focuses on the conjugation efficiency of the antibody with different sized gold nanoparticles. The effect of factors such as pH value and concentration of antibody has been quantificationally discussed using spectra methods after adding 1 wt% NaCl which induced gold nanoparticle aggregation. It was found that different sized gold nanoparticles had different conjugation efficiencies under different pH values and concentrations of antibody. Among the four sized gold nanoparticles, the 16 nm gold nanoparticles have the minimum requirement for antibody concentrations to avoid aggregation comparing to other sized gold nanoparticles but are less sensitive for detecting the real sample compared to the 38 nm gold nanoparticles. Consequently, different sized gold nanoparticles should be labeled with antibody under optimal pH value and optimal concentrations of antibody. It will be helpful for the application of antibody-labeled gold nanoparticles in the fields of clinic diagnosis, environmental analysis and so on in future.
Modeling the transport of engineered nanoparticles in saturated porous media - an experimental setup
NASA Astrophysics Data System (ADS)
Braun, A.; Neukum, C.; Azzam, R.
2011-12-01
The accelerating production and application of engineered nanoparticles is causing concerns regarding their release and fate in the environment. For assessing the risk that is posed to drinking water resources it is important to understand the transport and retention mechanisms of engineered nanoparticles in soil and groundwater. In this study an experimental setup for analyzing the mobility of silver and titanium dioxide nanoparticles in saturated porous media is presented. Batch and column experiments with glass beads and two different soils as matrices are carried out under varied conditions to study the impact of electrolyte concentration and pore water velocities. The analysis of nanoparticles implies several challenges, such as the detection and characterization and the preparation of a well dispersed sample with defined properties, as nanoparticles tend to form agglomerates when suspended in an aqueous medium. The analytical part of the experiments is mainly undertaken with Flow Field-Flow Fractionation (FlFFF). This chromatography like technique separates a particulate sample according to size. It is coupled to a UV/Vis and a light scattering detector for analyzing concentration and size distribution of the sample. The advantage of this technique is the ability to analyze also complex environmental samples, such as the effluent of column experiments including soil components, and the gentle sample treatment. For optimization of the sample preparation and for getting a first idea of the aggregation behavior in soil solutions, in sedimentation experiments the effect of ionic strength, sample concentration and addition of a surfactant on particle or aggregate size and temporal dispersion stability was investigated. In general the samples are more stable the lower the concentration of particles is. For TiO2 nanoparticles, the addition of a surfactant yielded the most stable samples with smallest aggregate sizes. Furthermore the suspension stability is increasing with electrolyte concentration. Depending on the dispersing medium the results show that TiO2 nanoparticles tend to form aggregates between 100-200 nm in diameter while the primary particle size is given as 21 nm by the manufacturer. Aggregate sizes are increasing with time. The particle size distribution of the silver nanoparticle samples is quite uniform in each medium. The fresh samples show aggregate sizes between 40 and 45 nm while the primary particle size is 15 nm according to the manufacturer. Aggregate size is only slightly increasing with time during the sedimentation experiments. These results are used as a reference when analyzing the effluent of column experiments.
Elemental Analysis of Beryllium Samples Using a Microzond-EGP-10 Unit
NASA Astrophysics Data System (ADS)
Buzoverya, M. E.; Karpov, I. A.; Gorodnov, A. A.; Shishpor, I. V.; Kireycheva, V. I.
2017-12-01
Results concerning the structural and elemental analysis of beryllium samples obtained via different technologies using a Microzond-EGP-10 unit with the help of the PIXE and RBS methods are presented. As a result, the overall chemical composition and the nature of inclusions were determined. The mapping method made it possible to reveal the structural features of beryllium samples: to select the grains of the main substance having different size and chemical composition, to visualize the interfaces between the regions of different composition, and to describe the features of the distribution of impurities in the samples.
Using lod scores to detect sex differences in male-female recombination fractions.
Feenstra, B; Greenberg, D A; Hodge, S E
2004-01-01
Human recombination fraction (RF) can differ between males and females, but investigators do not always know which disease genes are located in genomic areas of large RF sex differences. Knowledge of RF sex differences contributes to our understanding of basic biology and can increase the power of a linkage study, improve gene localization, and provide clues to possible imprinting. One way to detect these differences is to use lod scores. In this study we focused on detecting RF sex differences and answered the following questions, in both phase-known and phase-unknown matings: (1) How large a sample size is needed to detect a RF sex difference? (2) What are "optimal" proportions of paternally vs. maternally informative matings? (3) Does ascertaining nonoptimal proportions of paternally or maternally informative matings lead to ascertainment bias? Our results were as follows: (1) We calculated expected lod scores (ELODs) under two different conditions: "unconstrained," allowing sex-specific RF parameters (theta(female), theta(male)); and "constrained," requiring theta(female) = theta(male). We then examined the DeltaELOD (identical with difference between maximized constrained and unconstrained ELODs) and calculated minimum sample sizes required to achieve statistically significant DeltaELODs. For large RF sex differences, samples as small as 10 to 20 fully informative matings can achieve statistical significance. We give general sample size guidelines for detecting RF differences in informative phase-known and phase-unknown matings. (2) We defined p as the proportion of paternally informative matings in the dataset; and the optimal proportion p(circ) as that value of p that maximizes DeltaELOD. We determined that, surprisingly, p(circ) does not necessarily equal (1/2), although it does fall between approximately 0.4 and 0.6 in most situations. (3) We showed that if p in a sample deviates from its optimal value, no bias is introduced (asymptotically) to the maximum likelihood estimates of theta(female) and theta(male), even though ELOD is reduced (see point 2). This fact is important because often investigators cannot control the proportions of paternally and maternally informative families. In conclusion, it is possible to reliably detect sex differences in recombination fraction. Copyright 2004 S. Karger AG, Basel
Eberl, D.D.; Drits, V.A.; Środoń, Jan; Nüesch, R.
1996-01-01
Particle size may strongly influence the physical and chemical properties of a substance (e.g. its rheology, surface area, cation exchange capacity, solubility, etc.), and its measurement in rocks may yield geological information about ancient environments (sediment provenance, degree of metamorphism, degree of weathering, current directions, distance to shore, etc.). Therefore mineralogists, geologists, chemists, soil scientists, and others who deal with clay-size material would like to have a convenient method for measuring particle size distributions. Nano-size crystals generally are too fine to be measured by light microscopy. Laser scattering methods give only average particle sizes; therefore particle size can not be measured in a particular crystallographic direction. Also, the particles measured by laser techniques may be composed of several different minerals, and may be agglomerations of individual crystals. Measurement by electron and atomic force microscopy is tedious, expensive, and time consuming. It is difficult to measure more than a few hundred particles per sample by these methods. This many measurements, often taking several days of intensive effort, may yield an accurate mean size for a sample, but may be too few to determine an accurate distribution of sizes. Measurement of size distributions by X-ray diffraction (XRD) solves these shortcomings. An X-ray scan of a sample occurs automatically, taking a few minutes to a few hours. The resulting XRD peaks average diffraction effects from billions of individual nano-size crystals. The size that is measured by XRD may be related to the size of the individual crystals of the mineral in the sample, rather than to the size of particles formed from the agglomeration of these crystals. Therefore one can determine the size of a particular mineral in a mixture of minerals, and the sizes in a particular crystallographic direction of that mineral.
Accounting for randomness in measurement and sampling in studying cancer cell population dynamics.
Ghavami, Siavash; Wolkenhauer, Olaf; Lahouti, Farshad; Ullah, Mukhtar; Linnebacher, Michael
2014-10-01
Knowing the expected temporal evolution of the proportion of different cell types in sample tissues gives an indication about the progression of the disease and its possible response to drugs. Such systems have been modelled using Markov processes. We here consider an experimentally realistic scenario in which transition probabilities are estimated from noisy cell population size measurements. Using aggregated data of FACS measurements, we develop MMSE and ML estimators and formulate two problems to find the minimum number of required samples and measurements to guarantee the accuracy of predicted population sizes. Our numerical results show that the convergence mechanism of transition probabilities and steady states differ widely from the real values if one uses the standard deterministic approach for noisy measurements. This provides support for our argument that for the analysis of FACS data one should consider the observed state as a random variable. The second problem we address is about the consequences of estimating the probability of a cell being in a particular state from measurements of small population of cells. We show how the uncertainty arising from small sample sizes can be captured by a distribution for the state probability.
[Airborne Fungal Aerosol Concentration and Distribution Characteristics in Air- Conditioned Wards].
Zhang, Hua-ling; Feng, He-hua; Fang, Zi-liang; Wang, Ben-dong; Li, Dan
2015-04-01
The effects of airborne fungus on human health in the hospital environment are related to not only their genera and concentrations, but also their particle sizes and distribution characteristics. Moreover, the mechanisms of aerosols with different particle sizes on human health are different. Fungal samples were obtained in medicine wards of Chongqing using a six-stage sampler. The airborne fungal concentrations, genera and size distributions of all the sampling wards were investigated and identified in detail. Results showed that airborne fungal concentrations were not correlated to the diseases or personnel density, but were related to seasons, temperature, and relative humidity. The size distribution rule had roughly the same for testing wards in winter and summer. The size distributions were not related with diseases and seasons, the percentage of airborne fungal concentrations increased gradually from stage I to stage III, and then decreased dramatically from stage V to stage VI, in general, the size of airborne fungi was a normal distribution. There was no markedly difference for median diameter of airborne fungi which was less 3.19 μm in these wards. There were similar dominant genera in all wards. They were Aspergillus spp, Penicillium spp and Alternaria spp. Therefore, attention should be paid to improve the filtration efficiency of particle size of 1.1-4.7 μm for air conditioning system of wards. It also should be targeted to choose appropriate antibacterial methods and equipment for daily hygiene and air conditioning system operation management.
NASA Technical Reports Server (NTRS)
Allton, J. H.; Bevill, T. J.
2003-01-01
The strategy of raking rock fragments from the lunar regolith as a means of acquiring representative samples has wide support due to science return, spacecraft simplicity (reliability) and economy [3, 4, 5]. While there exists widespread agreement that raking or sieving the bulk regolith is good strategy, there is lively discussion about the minimum sample size. Advocates of consor-tium studies desire fragments large enough to support petrologic and isotopic studies. Fragments from 5 to 10 mm are thought adequate [4, 5]. Yet, Jolliff et al. [6] demonstrated use of 2-4 mm fragments as repre-sentative of larger rocks. Here we make use of cura-torial records and sample catalogs to give a different perspective on minimum sample size for a robotic sample collector.
Metric variation and sexual dimorphism in the dentition of Ouranopithecus macedoniensis.
Schrein, Caitlin M
2006-04-01
The fossil sample attributed to the late Miocene hominoid taxon Ouranopithecus macedoniensis is characterized by a high degree of dental metric variation. As a result, some researchers support a multiple-species taxonomy for this sample. Other researchers do not think that the sample variation is too great to be accommodated within one species. This study examines variation and sexual dimorphism in mandibular canine and postcanine dental metrics of an Ouranopithecus sample. Bootstrapping (resampling with replacement) of extant hominoid dental metric data is performed to test the hypothesis that the coefficients of variation (CV) and the indices of sexual dimorphism (ISD) of the fossil sample are not significantly different from those of modern great apes. Variation and sexual dimorphism in Ouranopithecus M(1) dimensions were statistically different from those of all extant ape samples; however, most of the dental metrics of Ouranopithecus were neither more variable nor more sexually dimorphic than those of Gorilla and Pongo. Similarly high levels of mandibular molar variation are known to characterize other fossil hominoid species. The Ouranopithecus specimens are morphologically homogeneous and it is probable that all but one specimen included in this study are from a single population. It is unlikely that the sample includes specimens of two sympatric large-bodied hominoid species. For these reasons, a single-species hypothesis is not rejected for the Ouranopithecus macedoniensis material. Correlations between mandibular first molar tooth size dimorphism and body size dimorphism indicate that O. macedoniensis and other extinct hominoids were more sexually size dimorphic than any living great apes, which suggests that social behaviors and life history profiles of these species may have been different from those of living species.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Trattner, Sigal; Cheng, Bin; Pieniazek, Radoslaw L.
2014-04-15
Purpose: Effective dose (ED) is a widely used metric for comparing ionizing radiation burden between different imaging modalities, scanners, and scan protocols. In computed tomography (CT), ED can be estimated by performing scans on an anthropomorphic phantom in which metal-oxide-semiconductor field-effect transistor (MOSFET) solid-state dosimeters have been placed to enable organ dose measurements. Here a statistical framework is established to determine the sample size (number of scans) needed for estimating ED to a desired precision and confidence, for a particular scanner and scan protocol, subject to practical limitations. Methods: The statistical scheme involves solving equations which minimize the sample sizemore » required for estimating ED to desired precision and confidence. It is subject to a constrained variation of the estimated ED and solved using the Lagrange multiplier method. The scheme incorporates measurement variation introduced both by MOSFET calibration, and by variation in MOSFET readings between repeated CT scans. Sample size requirements are illustrated on cardiac, chest, and abdomen–pelvis CT scans performed on a 320-row scanner and chest CT performed on a 16-row scanner. Results: Sample sizes for estimating ED vary considerably between scanners and protocols. Sample size increases as the required precision or confidence is higher and also as the anticipated ED is lower. For example, for a helical chest protocol, for 95% confidence and 5% precision for the ED, 30 measurements are required on the 320-row scanner and 11 on the 16-row scanner when the anticipated ED is 4 mSv; these sample sizes are 5 and 2, respectively, when the anticipated ED is 10 mSv. Conclusions: Applying the suggested scheme, it was found that even at modest sample sizes, it is feasible to estimate ED with high precision and a high degree of confidence. As CT technology develops enabling ED to be lowered, more MOSFET measurements are needed to estimate ED with the same precision and confidence.« less
Parajulee, M N; Shrestha, R B; Leser, J F
2006-04-01
A 2-yr field study was conducted to examine the effectiveness of two sampling methods (visual and plant washing techniques) for western flower thrips, Frankliniella occidentalis (Pergande), and five sampling methods (visual, beat bucket, drop cloth, sweep net, and vacuum) for cotton fleahopper, Pseudatomoscelis seriatus (Reuter), in Texas cotton, Gossypium hirsutum (L.), and to develop sequential sampling plans for each pest. The plant washing technique gave similar results to the visual method in detecting adult thrips, but the washing technique detected significantly higher number of thrips larvae compared with the visual sampling. Visual sampling detected the highest number of fleahoppers followed by beat bucket, drop cloth, vacuum, and sweep net sampling, with no significant difference in catch efficiency between vacuum and sweep net methods. However, based on fixed precision cost reliability, the sweep net sampling was the most cost-effective method followed by vacuum, beat bucket, drop cloth, and visual sampling. Taylor's Power Law analysis revealed that the field dispersion patterns of both thrips and fleahoppers were aggregated throughout the crop growing season. For thrips management decision based on visual sampling (0.25 precision), 15 plants were estimated to be the minimum sample size when the estimated population density was one thrips per plant, whereas the minimum sample size was nine plants when thrips density approached 10 thrips per plant. The minimum visual sample size for cotton fleahoppers was 16 plants when the density was one fleahopper per plant, but the sample size decreased rapidly with an increase in fleahopper density, requiring only four plants to be sampled when the density was 10 fleahoppers per plant. Sequential sampling plans were developed and validated with independent data for both thrips and cotton fleahoppers.
Shieh, G
2013-12-01
The use of effect sizes and associated confidence intervals in all empirical research has been strongly emphasized by journal publication guidelines. To help advance theory and practice in the social sciences, this article describes an improved procedure for constructing confidence intervals of the standardized mean difference effect size between two independent normal populations with unknown and possibly unequal variances. The presented approach has advantages over the existing formula in both theoretical justification and computational simplicity. In addition, simulation results show that the suggested one- and two-sided confidence intervals are more accurate in achieving the nominal coverage probability. The proposed estimation method provides a feasible alternative to the most commonly used measure of Cohen's d and the corresponding interval procedure when the assumption of homogeneous variances is not tenable. To further improve the potential applicability of the suggested methodology, the sample size procedures for precise interval estimation of the standardized mean difference are also delineated. The desired precision of a confidence interval is assessed with respect to the control of expected width and to the assurance probability of interval width within a designated value. Supplementary computer programs are developed to aid in the usefulness and implementation of the introduced techniques.
Oba, Yurika; Yamada, Toshihiro
2017-05-01
We estimated the sample size (the number of samples) required to evaluate the concentration of radiocesium ( 137 Cs) in Japanese fir (Abies firma Sieb. & Zucc.), 5 years after the outbreak of the Fukushima Daiichi Nuclear Power Plant accident. We investigated the spatial structure of the contamination levels in this species growing in a mixed deciduous broadleaf and evergreen coniferous forest stand. We sampled 40 saplings with a tree height of 150 cm-250 cm in a Fukushima forest community. The results showed that: (1) there was no correlation between the 137 Cs concentration in needles and soil, and (2) the difference in the spatial distribution pattern of 137 Cs concentration between needles and soil suggest that the contribution of root uptake to 137 Cs in new needles of this species may be minor in the 5 years after the radionuclides were released into the atmosphere. The concentration of 137 Cs in needles showed a strong positive spatial autocorrelation in the distance class from 0 to 2.5 m, suggesting that the statistical analysis of data should consider spatial autocorrelation in the case of an assessment of the radioactive contamination of forest trees. According to our sample size analysis, a sample size of seven trees was required to determine the mean contamination level within an error in the means of no more than 10%. This required sample size may be feasible for most sites. Copyright © 2017 Elsevier Ltd. All rights reserved.
Hislop, Jenni; Adewuyi, Temitope E.; Vale, Luke D.; Harrild, Kirsten; Fraser, Cynthia; Gurung, Tara; Altman, Douglas G.; Briggs, Andrew H.; Fayers, Peter; Ramsay, Craig R.; Norrie, John D.; Harvey, Ian M.; Buckley, Brian; Cook, Jonathan A.
2014-01-01
Background Randomised controlled trials (RCTs) are widely accepted as the preferred study design for evaluating healthcare interventions. When the sample size is determined, a (target) difference is typically specified that the RCT is designed to detect. This provides reassurance that the study will be informative, i.e., should such a difference exist, it is likely to be detected with the required statistical precision. The aim of this review was to identify potential methods for specifying the target difference in an RCT sample size calculation. Methods and Findings A comprehensive systematic review of medical and non-medical literature was carried out for methods that could be used to specify the target difference for an RCT sample size calculation. The databases searched were MEDLINE, MEDLINE In-Process, EMBASE, the Cochrane Central Register of Controlled Trials, the Cochrane Methodology Register, PsycINFO, Science Citation Index, EconLit, the Education Resources Information Center (ERIC), and Scopus (for in-press publications); the search period was from 1966 or the earliest date covered, to between November 2010 and January 2011. Additionally, textbooks addressing the methodology of clinical trials and International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) tripartite guidelines for clinical trials were also consulted. A narrative synthesis of methods was produced. Studies that described a method that could be used for specifying an important and/or realistic difference were included. The search identified 11,485 potentially relevant articles from the databases searched. Of these, 1,434 were selected for full-text assessment, and a further nine were identified from other sources. Fifteen clinical trial textbooks and the ICH tripartite guidelines were also reviewed. In total, 777 studies were included, and within them, seven methods were identified—anchor, distribution, health economic, opinion-seeking, pilot study, review of the evidence base, and standardised effect size. Conclusions A variety of methods are available that researchers can use for specifying the target difference in an RCT sample size calculation. Appropriate methods may vary depending on the aim (e.g., specifying an important difference versus a realistic difference), context (e.g., research question and availability of data), and underlying framework adopted (e.g., Bayesian versus conventional statistical approach). Guidance on the use of each method is given. No single method provides a perfect solution for all contexts. Please see later in the article for the Editors' Summary PMID:24824338
Digital image processing of nanometer-size metal particles on amorphous substrates
NASA Technical Reports Server (NTRS)
Soria, F.; Artal, P.; Bescos, J.; Heinemann, K.
1989-01-01
The task of differentiating very small metal aggregates supported on amorphous films from the phase contrast image features inherently stemming from the support is extremely difficult in the nanometer particle size range. Digital image processing was employed to overcome some of the ambiguities in evaluating such micrographs. It was demonstrated that such processing allowed positive particle detection and a limited degree of statistical size analysis even for micrographs where by bare eye examination the distribution between particles and erroneous substrate features would seem highly ambiguous. The smallest size class detected for Pd/C samples peaks at 0.8 nm. This size class was found in various samples prepared under different evaporation conditions and it is concluded that these particles consist of 'a magic number' of 13 atoms and have cubooctahedral or icosahedral crystal structure.
Qiu, Xing; Hu, Rui; Wu, Zhixin
2014-01-01
Normalization procedures are widely used in high-throughput genomic data analyses to remove various technological noise and variations. They are known to have profound impact to the subsequent gene differential expression analysis. Although there has been some research in evaluating different normalization procedures, few attempts have been made to systematically evaluate the gene detection performances of normalization procedures from the bias-variance trade-off point of view, especially with strong gene differentiation effects and large sample size. In this paper, we conduct a thorough study to evaluate the effects of normalization procedures combined with several commonly used statistical tests and MTPs under different configurations of effect size and sample size. We conduct theoretical evaluation based on a random effect model, as well as simulation and biological data analyses to verify the results. Based on our findings, we provide some practical guidance for selecting a suitable normalization procedure under different scenarios. PMID:24941114
Hennig, Cheryl; Cooper, David
2011-08-01
Histomorphometric aging methods report varying degrees of precision, measured through Standard Error of the Estimate (SEE). These techniques have been developed from variable samples sizes (n) and the impact of n on reported aging precision has not been rigorously examined in the anthropological literature. This brief communication explores the relation between n and SEE through a review of the literature (abstracts, articles, book chapters, theses, and dissertations), predictions based upon sampling theory and a simulation. Published SEE values for age prediction, derived from 40 studies, range from 1.51 to 16.48 years (mean 8.63; sd: 3.81 years). In general, these values are widely distributed for smaller samples and the distribution narrows as n increases--a pattern expected from sampling theory. For the two studies that have samples in excess of 200 individuals, the SEE values are very similar (10.08 and 11.10 years) with a mean of 10.59 years. Assuming this mean value is a 'true' characterization of the error at the population level, the 95% confidence intervals for SEE values from samples of 10, 50, and 150 individuals are on the order of ± 4.2, 1.7, and 1.0 years, respectively. While numerous sources of variation potentially affect the precision of different methods, the impact of sample size cannot be overlooked. The uncertainty associated with SEE values derived from smaller samples complicates the comparison of approaches based upon different methodology and/or skeletal elements. Meaningful comparisons require larger samples than have frequently been used and should ideally be based upon standardized samples. Copyright © 2011 Wiley-Liss, Inc.
Sources of variability in collection and preparation of paint and lead-coating samples.
Harper, S L; Gutknecht, W F
2001-06-01
Chronic exposure of children to lead (Pb) can result in permanent physiological impairment. Since surfaces coated with lead-containing paints and varnishes are potential sources of exposure, it is extremely important that reliable methods for sampling and analysis be available. The sources of variability in the collection and preparation of samples were investigated to improve the performance and comparability of methods and to ensure that data generated will be adequate for its intended use. Paint samples of varying sizes (areas and masses) were collected at different locations across a variety of surfaces including metal, plaster, concrete, and wood. A variety of grinding techniques were compared. Manual mortar and pestle grinding for at least 1.5 min and mechanized grinding techniques were found to generate similar homogenous particle size distributions required for aliquots as small as 0.10 g. When 342 samples were evaluated for sample weight loss during mortar and pestle grinding, 4% had 20% or greater loss with a high of 41%. Homogenization and sub-sampling steps were found to be the principal sources of variability related to the size of the sample collected. Analysis of samples from different locations on apparently identical surfaces were found to vary by more than a factor of two both in Pb concentration (mg cm-2 or %) and areal coating density (g cm-2). Analyses of substrates were performed to determine the Pb remaining after coating removal. Levels as high as 1% Pb were found in some substrate samples, corresponding to more than 35 mg cm-2 Pb. In conclusion, these sources of variability must be considered in development and/or application of any sampling and analysis methodologies.
Very sensitive α-Al2O3:C polycrystals for thermoluminescent dosimetry.
Fontainha, Críssia Carem Paiva; Alves, Neriene; Ferraz, Wilmar Barbosa; de Faria, Luiz Oliveira
2018-05-07
New materials have been widely investigated for ionizing radiation dosimetry for medical procedures. Carbon-doped alumina (α-Al 2 O 3 :C) have been reported to be excellent thermoluminescent (TL) and optically stimulated luminescence (OSL) radiation dosimeters. In the present study, we have synthetized nano and micro-sized α-Al 2 O 3 :C polycrystals, doped with different percentages of carbon atoms aiming to compare their efficiency as TL dosimeters. The dosimetric characteristics for X ray and gamma fields were investigated. Samples doped with different amounts of carbon atoms were sintered under different atmosphere conditions, at temperatures ranging from 1300 °C to 1750 °C. Among the investigated samples, the micro-sized alumina doped with 0.01% of carbon and sintered at 1700 °C under reducing atmosphere, has presented a very high TL output. The main TL peak is centered at 250 °C and has a linear behavior with photon dose in the dose range of 0.02-to-5000 mGy, with correlation coefficient very close to one (0.99991). Samples produced by using nanosized alumina have shown much lower TL output when compared to the samples with microsized alumina. The micro-sized alumina obtained by the methodology used in this work is a suitable candidate to be explored for application in X and Gamma radiation dosimetry. Copyright © 2018. Published by Elsevier Ltd.
No rationale for 1 variable per 10 events criterion for binary logistic regression analysis.
van Smeden, Maarten; de Groot, Joris A H; Moons, Karel G M; Collins, Gary S; Altman, Douglas G; Eijkemans, Marinus J C; Reitsma, Johannes B
2016-11-24
Ten events per variable (EPV) is a widely advocated minimal criterion for sample size considerations in logistic regression analysis. Of three previous simulation studies that examined this minimal EPV criterion only one supports the use of a minimum of 10 EPV. In this paper, we examine the reasons for substantial differences between these extensive simulation studies. The current study uses Monte Carlo simulations to evaluate small sample bias, coverage of confidence intervals and mean square error of logit coefficients. Logistic regression models fitted by maximum likelihood and a modified estimation procedure, known as Firth's correction, are compared. The results show that besides EPV, the problems associated with low EPV depend on other factors such as the total sample size. It is also demonstrated that simulation results can be dominated by even a few simulated data sets for which the prediction of the outcome by the covariates is perfect ('separation'). We reveal that different approaches for identifying and handling separation leads to substantially different simulation results. We further show that Firth's correction can be used to improve the accuracy of regression coefficients and alleviate the problems associated with separation. The current evidence supporting EPV rules for binary logistic regression is weak. Given our findings, there is an urgent need for new research to provide guidance for supporting sample size considerations for binary logistic regression analysis.
Confidence Interval Coverage for Cohen's Effect Size Statistic
ERIC Educational Resources Information Center
Algina, James; Keselman, H. J.; Penfield, Randall D.
2006-01-01
Kelley compared three methods for setting a confidence interval (CI) around Cohen's standardized mean difference statistic: the noncentral-"t"-based, percentile (PERC) bootstrap, and biased-corrected and accelerated (BCA) bootstrap methods under three conditions of nonnormality, eight cases of sample size, and six cases of population…
Organizational Correlates of Management Training Interests.
ERIC Educational Resources Information Center
Tills, Marvin
A study was made of a sample of Wisconsin manufacturing firms and a subsample of firms in different size categories to determine organizational correlates of management training interests. Correlations were sought between characteristics of firms (ownership, relationship to parent company, size of employment, market orientation, growth trends,…
Vosoogh, Ali; Saeedi, Mohsen; Lak, Raziyeh
2016-11-01
Some pollutants can qualitatively affect aquatic freshwater such as rivers, and heavy metals are one of the most important pollutants in aquatic fresh waters. Heavy metals can be found in the form of components dissolved in these waters or in compounds with suspended particles and surface sediments. It can be said that heavy metals are in equilibrium between water and sediment. In this study, the amount of heavy metals is determined in water and different sizes of sediment. To obtain the relationship between heavy metals in water and size-fractionated sediments, a canonical correlation analysis (CCA) was utilized in rivers of the southwestern Caspian Sea. In this research, a case study was carried out on 18 sampling stations in nine rivers. In the first step, the concentrations of heavy metals (Cu, Zn, Cr, Fe, Mn, Pb, Ni, and Cd) were determined in water and size-fractionated sediment samples. Water sampling sites were classified by hierarchical cluster analysis (HCA) utilizing squared Euclidean distance with Ward's method. In addition, for interpreting the obtained results and the relationships between the concentration of heavy metals in the tested river water and sample sediments, canonical correlation analysis (CCA) was utilized. The rivers were grouped into two classes (those having no pollution and those having low pollution) based on the HCA results obtained for river water samples. CCA results found numerous relationships between rivers in Iran's Guilan province and their size-fractionated sediments samples. The heavy metals of sediments with 0.038 to 0.125 mm size in diameter are slightly correlated with those of water samples.
Habermehl, Christina; Benner, Axel; Kopp-Schneider, Annette
2018-03-01
In recent years, numerous approaches for biomarker-based clinical trials have been developed. One of these developments are multiple-biomarker trials, which aim to investigate multiple biomarkers simultaneously in independent subtrials. For low-prevalence biomarkers, small sample sizes within the subtrials have to be expected, as well as many biomarker-negative patients at the screening stage. The small sample sizes may make it unfeasible to analyze the subtrials individually. This imposes the need to develop new approaches for the analysis of such trials. With an expected large group of biomarker-negative patients, it seems reasonable to explore options to benefit from including them in such trials. We consider advantages and disadvantages of the inclusion of biomarker-negative patients in a multiple-biomarker trial with a survival endpoint. We discuss design options that include biomarker-negative patients in the study and address the issue of small sample size bias in such trials. We carry out a simulation study for a design where biomarker-negative patients are kept in the study and are treated with standard of care. We compare three different analysis approaches based on the Cox model to examine if the inclusion of biomarker-negative patients can provide a benefit with respect to bias and variance of the treatment effect estimates. We apply the Firth correction to reduce the small sample size bias. The results of the simulation study suggest that for small sample situations, the Firth correction should be applied to adjust for the small sample size bias. Additional to the Firth penalty, the inclusion of biomarker-negative patients in the analysis can lead to further but small improvements in bias and standard deviation of the estimates. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Sample size and allocation of effort in point count sampling of birds in bottomland hardwood forests
Smith, W.P.; Twedt, D.J.; Cooper, R.J.; Wiedenfeld, D.A.; Hamel, P.B.; Ford, R.P.; Ralph, C. John; Sauer, John R.; Droege, Sam
1995-01-01
To examine sample size requirements and optimum allocation of effort in point count sampling of bottomland hardwood forests, we computed minimum sample sizes from variation recorded during 82 point counts (May 7-May 16, 1992) from three localities containing three habitat types across three regions of the Mississippi Alluvial Valley (MAV). Also, we estimated the effect of increasing the number of points or visits by comparing results of 150 four-minute point counts obtained from each of four stands on Delta Experimental Forest (DEF) during May 8-May 21, 1991 and May 30-June 12, 1992. For each stand, we obtained bootstrap estimates of mean cumulative number of species each year from all possible combinations of six points and six visits. ANOVA was used to model cumulative species as a function of number of points visited, number of visits to each point, and interaction of points and visits. There was significant variation in numbers of birds and species between regions and localities (nested within region); neither habitat, nor the interaction between region and habitat, was significant. For a = 0.05 and a = 0.10, minimum sample size estimates (per factor level) varied by orders of magnitude depending upon the observed or specified range of desired detectable difference. For observed regional variation, 20 and 40 point counts were required to accommodate variability in total individuals (MSE = 9.28) and species (MSE = 3.79), respectively, whereas ? 25 percent of the mean could be achieved with five counts per factor level. Sample size sufficient to detect actual differences of Wood Thrush (Hylocichla mustelina) was >200, whereas the Prothonotary Warbler (Protonotaria citrea) required <10 counts. Differences in mean cumulative species were detected among number of points visited and among number of visits to a point. In the lower MAV, mean cumulative species increased with each added point through five points and with each additional visit through four visits. Although no interaction was detected between number of points and number of visits, when paired reciprocals were compared, more points invariably yielded a significantly greater cumulative number of species than more visits to a point. Still, 36 point counts per stand during each of two breeding seasons detected only 52 percent of the known available species pool in DEF.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jalava, Pasi I.; Salonen, Raimo O.; Haelinen, Arja I.
2006-09-15
The impact of long-range transport (LRT) episodes of wildfire smoke on the inflammogenic and cytotoxic activity of urban air particles was investigated in the mouse RAW 264.7 macrophages. The particles were sampled in four size ranges using a modified Harvard high-volume cascade impactor, and the samples were chemically characterized for identification of different emission sources. The particulate mass concentration in the accumulation size range (PM{sub 1-0.2}) was highly increased during two LRT episodes, but the contents of total and genotoxic polycyclic aromatic hydrocarbons (PAH) in collected particulate samples were only 10-25% of those in the seasonal average sample. The abilitymore » of coarse (PM{sub 10-2.5}), intermodal size range (PM{sub 2.5-1}), PM{sub 1-0.2} and ultrafine (PM{sub 0.2}) particles to cause cytokine production (TNF{alpha}, IL-6, MIP-2) reduced along with smaller particle size, but the size range had a much smaller impact on induced nitric oxide (NO) production and cytotoxicity or apoptosis. The aerosol particles collected during LRT episodes had a substantially lower activity in cytokine production than the corresponding particles of the seasonal average period, which is suggested to be due to chemical transformation of the organic fraction during aging. However, the episode events were associated with enhanced inflammogenic and cytotoxic activities per inhaled cubic meter of air due to the greatly increased particulate mass concentration in the accumulation size range, which may have public health implications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Papelis, Charalambos; Um, Wooyong; Russel, Charles E.
2003-03-28
The specific surface area of natural and manmade solid materials is a key parameter controlling important interfacial processes in natural environments and engineered systems, including dissolution reactions and sorption processes at solid-fluid interfaces. To improve our ability to quantify the release of trace elements trapped in natural glasses, the release of hazardous compounds trapped in manmade glasses, or the release of radionuclides from nuclear melt glass, we measured the specific surface area of natural and manmade glasses as a function of particle size, morphology, and composition. Volcanic ash, volcanic tuff, tektites, obsidian glass, and in situ vitrified rock were analyzed.more » Specific surface area estimates were obtained using krypton as gas adsorbent and the BET model. The range of surface areas measured exceeded three orders of magnitude. A tektite sample had the highest surface area (1.65 m2/g), while one of the samples of in situ vitrified rock had the lowest surf ace area (0.0016 m2/g). The specific surface area of the samples was a function of particle size, decreasing with increasing particle size. Different types of materials, however, showed variable dependence on particle size, and could be assigned to one of three distinct groups: (1) samples with low surface area dependence on particle size and surface areas approximately two orders of magnitude higher than the surface area of smooth spheres of equivalent size. The specific surface area of these materials was attributed mostly to internal porosity and surface roughness. (2) samples that showed a trend of decreasing surface area dependence on particle size as the particle size increased. The minimum specific surface area of these materials was between 0.1 and 0.01 m2/g and was also attributed to internal porosity and surface roughness. (3) samples whose surface area showed a monotonic decrease with increasing particle size, never reaching an ultimate surface area limit within the particle size range examined. The surface area results were consistent with particle morphology, examined by scanning electron microscopy, and have significant implications for the release of radionuclides and toxic metals in the environment.« less
Classifier performance prediction for computer-aided diagnosis using a limited dataset.
Sahiner, Berkman; Chan, Heang-Ping; Hadjiiski, Lubomir
2008-04-01
In a practical classifier design problem, the true population is generally unknown and the available sample is finite-sized. A common approach is to use a resampling technique to estimate the performance of the classifier that will be trained with the available sample. We conducted a Monte Carlo simulation study to compare the ability of the different resampling techniques in training the classifier and predicting its performance under the constraint of a finite-sized sample. The true population for the two classes was assumed to be multivariate normal distributions with known covariance matrices. Finite sets of sample vectors were drawn from the population. The true performance of the classifier is defined as the area under the receiver operating characteristic curve (AUC) when the classifier designed with the specific sample is applied to the true population. We investigated methods based on the Fukunaga-Hayes and the leave-one-out techniques, as well as three different types of bootstrap methods, namely, the ordinary, 0.632, and 0.632+ bootstrap. The Fisher's linear discriminant analysis was used as the classifier. The dimensionality of the feature space was varied from 3 to 15. The sample size n2 from the positive class was varied between 25 and 60, while the number of cases from the negative class was either equal to n2 or 3n2. Each experiment was performed with an independent dataset randomly drawn from the true population. Using a total of 1000 experiments for each simulation condition, we compared the bias, the variance, and the root-mean-squared error (RMSE) of the AUC estimated using the different resampling techniques relative to the true AUC (obtained from training on a finite dataset and testing on the population). Our results indicated that, under the study conditions, there can be a large difference in the RMSE obtained using different resampling methods, especially when the feature space dimensionality is relatively large and the sample size is small. Under this type of conditions, the 0.632 and 0.632+ bootstrap methods have the lowest RMSE, indicating that the difference between the estimated and the true performances obtained using the 0.632 and 0.632+ bootstrap will be statistically smaller than those obtained using the other three resampling methods. Of the three bootstrap methods, the 0.632+ bootstrap provides the lowest bias. Although this investigation is performed under some specific conditions, it reveals important trends for the problem of classifier performance prediction under the constraint of a limited dataset.
Effects of sample size and sampling frequency on studies of brown bear home ranges and habitat use
Arthur, Steve M.; Schwartz, Charles C.
1999-01-01
We equipped 9 brown bears (Ursus arctos) on the Kenai Peninsula, Alaska, with collars containing both conventional very-high-frequency (VHF) transmitters and global positioning system (GPS) receivers programmed to determine an animal's position at 5.75-hr intervals. We calculated minimum convex polygon (MCP) and fixed and adaptive kernel home ranges for randomly-selected subsets of the GPS data to examine the effects of sample size on accuracy and precision of home range estimates. We also compared results obtained by weekly aerial radiotracking versus more frequent GPS locations to test for biases in conventional radiotracking data. Home ranges based on the MCP were 20-606 km2 (x = 201) for aerial radiotracking data (n = 12-16 locations/bear) and 116-1,505 km2 (x = 522) for the complete GPS data sets (n = 245-466 locations/bear). Fixed kernel home ranges were 34-955 km2 (x = 224) for radiotracking data and 16-130 km2 (x = 60) for the GPS data. Differences between means for radiotracking and GPS data were due primarily to the larger samples provided by the GPS data. Means did not differ between radiotracking data and equivalent-sized subsets of GPS data (P > 0.10). For the MCP, home range area increased and variability decreased asymptotically with number of locations. For the kernel models, both area and variability decreased with increasing sample size. Simulations suggested that the MCP and kernel models required >60 and >80 locations, respectively, for estimates to be both accurate (change in area <1%/additional location) and precise (CV < 50%). Although the radiotracking data appeared unbiased, except for the relationship between area and sample size, these data failed to indicate some areas that likely were important to bears. Our results suggest that the usefulness of conventional radiotracking data may be limited by potential biases and variability due to small samples. Investigators that use home range estimates in statistical tests should consider the effects of variability of those estimates. Use of GPS-equipped collars can facilitate obtaining larger samples of unbiased data and improve accuracy and precision of home range estimates.
Large exchange bias effect in NiFe2O4/CoO nanocomposites
NASA Astrophysics Data System (ADS)
Mohan, Rajendra; Prasad Ghosh, Mritunjoy; Mukherjee, Samrat
2018-03-01
In this work, we report the exchange bias effect of NiFe2O4/CoO nanocomposites, synthesized via chemical co-precipitation method. Four samples of different particle size ranging from 4 nm to 31 nm were prepared with the annealing temperature varying from 200 °C to 800 °C. X-ray diffraction analysis of all the samples confirmed the presence of cubic spinel phase of Nickel ferrite along with CoO phase without trace of any impurity. Sizes of the particles were studied from transmission electron micrographs and were found to be in agreement with those estimated from x-ray diffraction. Field cooled (FC) hysteresis loops at 5 K revealed an exchange bias (HE) of 2.2 kOe for the sample heated at 200 °C which decreased with the increase of particle size. Exchange bias expectedly vanished at 300 K due to high thermal energy (kBT) and low effective surface anisotropy. M-T curves revealed a blocking temperature of 135 K for the sample with smaller particle size.
Detection of internal structure by scattered light intensity: Application to kidney cell sorting
NASA Technical Reports Server (NTRS)
Goolsby, C. L.; Kunze, M. E.
1985-01-01
Scattered light measurements in flow cytometry were sucessfully used to distinguish cells on the basis of differing morphology and internal structure. Differences in scattered light patterns due to changes in internal structure would be expected to occur at large scattering angles. Practically, the results of these calculations suggest that in experimental situations an array of detectors would be useful. Although in general the detection of the scattered light intensity at several intervals within the 10 to 60 region would be sufficient, there are many examples where increased sensitivity could be acheived at other angles. The ability to measure at many different angular intervals would allow the experimenter to empirically select the optimum intervals for the varying conditions of cell size, N/C ratio, granule size and internal structure from sample to sample. The feasibility of making scattered light measurements at many different intervals in flow cytometry was demonstrated. The implementation of simplified versions of these techniques in conjunction with independant measurements of cell size could potentially improve the usefulness of flow cytometry in the study of the internal structure of cells.
Investigating Test Equating Methods in Small Samples through Various Factors
ERIC Educational Resources Information Center
Asiret, Semih; Sünbül, Seçil Ömür
2016-01-01
In this study, equating methods for random group design using small samples through factors such as sample size, difference in difficulty between forms, and guessing parameter was aimed for comparison. Moreover, which method gives better results under which conditions was also investigated. In this study, 5,000 dichotomous simulated data…
Influence of androgen receptor repeat polymorphisms on personality traits in men
Westberg, Lars; Henningsson, Susanne; Landén, Mikael; Annerbrink, Kristina; Melke, Jonas; Nilsson, Staffan; Rosmond, Roland; Holm, Göran; Anckarsäter, Henrik; Eriksson, Elias
2009-01-01
Background Testosterone has been attributed importance for various aspects of behaviour. The aim of our study was to investigate the potential influence of 2 functional polymorphisms in the amino terminal of the androgen receptor on personality traits in men. Methods We assessed and genotyped 141 men born in 1944 recruited from the general population. We used 2 different instruments: the Karolinska Scales of Personality and the Temperament and Character Inventory. For replication, we similarly assessed 63 men recruited from a forensic psychiatry study group. Results In the population-recruited sample, the lengths of the androgen receptor repeats were associated with neuroticism, extraversion and self-transcendence. The association with extraversion was replicated in the independent sample. Limitations Our 2 samples differed in size; sample 1 was of moderate size and sample 2 was small. In addition, the homogeneity of sample 1 probably enhanced our ability to detect significant associations between genotype and phenotype. Conclusion Our results suggest that the repeat polymorphisms in the androgen receptor gene may influence personality traits in men. PMID:19448851
Stormer, Ame; Tun, Waimar; Guli, Lisa; Harxhi, Arjan; Bodanovskaia, Zinaida; Yakovleva, Anna; Rusakova, Maia; Levina, Olga; Bani, Roland; Rjepaj, Klodian; Bino, Silva
2006-11-01
Injection drug users in Tirana, Albania and St. Petersburg, Russia were recruited into a study assessing HIV-related behaviors and HIV serostatus using Respondent Driven Sampling (RDS), a peer-driven recruitment sampling strategy that results in a probability sample. (Salganik M, Heckathorn DD. Sampling and estimation in hidden populations using respondent-driven sampling. Sociol Method. 2004;34:193-239). This paper presents a comparison of RDS implementation, findings on network and recruitment characteristics, and lessons learned. Initiated with 13 to 15 seeds, approximately 200 IDUs were recruited within 8 weeks. Information resulting from RDS indicates that social network patterns from the two studies differ greatly. Female IDUs in Tirana had smaller network sizes than male IDUs, unlike in St. Petersburg where female IDUs had larger network sizes than male IDUs. Recruitment patterns in each country also differed by demographic categories. Recruitment analyses indicate that IDUs form socially distinct groups by sex in Tirana, whereas there was a greater degree of gender mixing patterns in St. Petersburg. RDS proved to be an effective means of surveying these hard-to-reach populations.
... Some labs use different measurements or test different samples. Talk to your provider about the meaning of your ... saliva test. BLOOD TEST Veins and arteries vary in size from one person to another and from one side of ...
... Some labs use different measurements or test different samples. Talk to your health care provider about the meaning of your ... Veins and arteries vary in size from one person to another and from one side of ...
Impact of asymmetrical flow field-flow fractionation on protein aggregates stability.
Bria, Carmen R M; Williams, S Kim Ratanathanawongs
2016-09-23
The impact of asymmetrical flow field-flow fractionation (AF4) on protein aggregate species is investigated with the aid of multiangle light scattering (MALS) and dynamic light scattering (DLS). The experimental parameters probed in this study include aggregate stability in different carrier liquids, shear stress (related to sample injection), sample concentration (during AF4 focusing), and sample dilution (during separation). Two anti-streptavidin (anti-SA) IgG1 samples composed of low and high molar mass (M) aggregates are subjected to different AF4 conditions. Aggregates suspended and separated in phosphate buffer are observed to dissociate almost entirely to monomer. However, aggregates in citric acid buffer are partially stable with dissociation to 25% and 5% monomer for the low and high M samples, respectively. These results demonstrate that different carrier liquids change the aggregate stability and low M aggregates can behave differently than their larger counterparts. Increasing the duration of the AF4 focusing step showed no significant changes in the percent monomer, percent aggregates, or the average Ms in either sample. Syringe-induced shear related to sample injection resulted in an increase in hydrodynamic diameter (dh) as measured by batch mode DLS. Finally, calculations showed that dilution during AF4 separation is significantly lower than in size exclusion chromatography with dilution occurring mainly at the AF4 channel outlet and not during the separation. This has important ramifications when analyzing aggregates that rapidly dissociate (<∼2s) upon dilution as the size calculated by AF4 theory may be more accurate than that measured by online DLS. Experimentally, the dhs determined by online DLS generally agreed with AF4 theory except for the more well retained larger aggregates for which DLS showed smaller sizes. These results highlight the importance of using AF4 retention theory to understand the impacts of dilution on analytes. Copyright © 2016 Elsevier B.V. All rights reserved.
Porosity characterization for heterogeneous shales using integrated multiscale microscopy
NASA Astrophysics Data System (ADS)
Rassouli, F.; Andrew, M.; Zoback, M. D.
2016-12-01
Pore size distribution analysis plays a critical role in gas storage capacity and fluid transport characterization of shales. Study of the diverse distribution of pore size and structure in such low permeably rocks is withheld by the lack of tools to visualize the microstructural properties of shale rocks. In this paper we try to use multiple techniques to investigate the full pore size range in different sample scales. Modern imaging techniques are combined with routine analytical investigations (x-ray diffraction, thin section analysis and mercury porosimetry) to describe pore size distribution of shale samples from Haynesville formation in East Texas to generate a more holistic understanding of the porosity structure in shales, ranging from standard core plug down to nm scales. Standard 1" diameter core plug samples were first imaged using a Versa 3D x-ray microscope at lower resolutions. Then we pick several regions of interest (ROIs) with various micro-features (such as micro-cracks and high organic matters) in the rock samples to run higher resolution CT scans using a non-destructive interior tomography scans. After this step, we cut the samples and drill 5 mm diameter cores out of the selected ROIs. Then we rescan the samples to measure porosity distribution of the 5 mm cores. We repeat this step for samples with diameter of 1 mm being cut out of the 5 mm cores using a laser cutting machine. After comparing the pore structure and distribution of the samples measured form micro-CT analysis, we move to nano-scale imaging to capture the ultra-fine pores within the shale samples. At this stage, the diameter of the 1 mm samples will be milled down to 70 microns using the laser beam. We scan these samples in a nano-CT Ultra x-ray microscope and calculate the porosity of the samples by image segmentation methods. Finally, we use images collected from focused ion beam scanning electron microscopy (FIB-SEM) to be able to compare the results of porosity measurements from all different imaging techniques. These multi-scale characterization techniques are then compared with traditional analytical techniques such as Mercury Porosimetry.
Gondikas, Andreas; von der Kammer, Frank; Hofmann, Thilo; Marchetti-Deschmann, Martina; Allmaier, Günter; Marko-Varga, György; Andersson, Roland
2017-01-01
For drug delivery, characterization of liposomes regarding size, particle number concentrations, occurrence of low-sized liposome artefacts and drug encapsulation are of importance to understand their pharmacodynamic properties. In our study, we aimed to demonstrate the applicability of nano Electrospray Gas-Phase Electrophoretic Mobility Molecular Analyser (nES GEMMA) as a suitable technique for analyzing these parameters. We measured number-based particle concentrations, identified differences in size between nominally identical liposomal samples, and detected the presence of low-diameter material which yielded bimodal particle size distributions. Subsequently, we compared these findings to dynamic light scattering (DLS) data and results from light scattering experiments coupled to Asymmetric Flow-Field Flow Fractionation (AF4), the latter improving the detectability of smaller particles in polydisperse samples due to a size separation step prior detection. However, the bimodal size distribution could not be detected due to method inherent limitations. In contrast, cryo transmission electron microscopy corroborated nES GEMMA results. Hence, gas-phase electrophoresis proved to be a versatile tool for liposome characterization as it could analyze both vesicle size and size distribution. Finally, a correlation of nES GEMMA results with cell viability experiments was carried out to demonstrate the importance of liposome batch-to-batch control as low-sized sample components possibly impact cell viability. PMID:27639623
Variable-Size Bead Layer as Standard Reference for Endothelial Microscopes.
Tufo, Simona; Prazzoli, Erica; Ferraro, Lorenzo; Cozza, Federica; Borghesi, Alessandro; Tavazzi, Silvia
2017-02-01
For morphometric analysis of the cell mosaic of corneal endothelium, checking accuracy and precision of instrumentation is a key step. In this study, a standard reference sample is proposed, developed to reproduce the cornea with its shape and the endothelium with its intrinsic variability in the cell size. A polystyrene bead layer (representing the endothelium) was deposited on a lens (representing the cornea). Bead diameters were 20, 25, and 30 μm (fractions in number 55%, 30%, and 15%, respectively). Bead density and hexagonality were simulated to obtain the expected true values and measured using a slit-lamp endothelial microscope applied to 1) a Takagi 700GL slit lamp at 40× magnification (recommended standard setup) and 2) a Takagi 2ZL slit lamp at 25× magnification. The simulation provided the expected bead density 2001 mm and hexagonality 47%. At 40×, density and hexagonality were measured to be 2009 mm (SD 93 mm) and 45% (SD 3%). At 25× on a different slit lamp, the comparison between measured and expected densities provided the factor 1.526 to resize the image and to use the current algorithms of the slit-lamp endothelial microscope for cell recognition. A variable-size polystyrene bead layer on a lens is proposed as a standard sample mimicking the real shape of the cornea and the variability of cell size and cell arrangement of corneal endothelium. The sample is suggested to evaluate accuracy and precision of cell density and hexagonality obtained by different endothelial microscopes, including a slit-lamp endothelial microscope applied to different slit lamps, also at different magnifications.
Densmore, Brenda K.; Rus, David L.; Moser, Matthew T.; Hall, Brent M.; Andersen, Michael J.
2016-02-04
Comparisons of concentrations and loads from EWI samples collected from different transects within a study site resulted in few significant differences, but comparisons are limited by small sample sizes and large within-transect variability. When comparing the Missouri River upstream transect to the chute inlet transect, similar results were determined in 2012 as were determined in 2008—the chute inlet affected the amount of sediment entering the chute from the main channel. In addition, the Kansas chute is potentially affecting the sediment concentration within the Missouri River main channel, but small sample size and construction activities within the chute limit the ability to fully understand either the effect of the chute in 2012 or the effect of the chute on the main channel during a year without construction. Finally, some differences in SSC were detected between the Missouri River upstream transects and the chute downstream transects; however, the effect of the chutes on the Missouri River main-channel sediment transport was difficult to isolate because of construction activities and sampling variability.
Evaluation of Low-Gravity Smoke Particulate for Spacecraft Fire Detection
NASA Technical Reports Server (NTRS)
Urban, David; Ruff, Gary A.; Mulholland George; Meyer, Marit; Yuan, Zeng guang; Cleary, Thomas; Yang, Jiann; Greenberg, Paul; Bryg, Victoria
2013-01-01
Tests were conducted on the International Space Station to evaluate the smoke particulate size from materials and conditions that are typical of those expected in spacecraft fires. Five different materials representative of those found in spacecraft (Teflon, Kapton, cotton, silicone rubber and Pyrell) were heated to temperatures below the ignition point with conditions controlled to provide repeatable sample surface temperatures and air flow. The air flow past the sample during the heating period ranged from quiescent to 8 cm/s. The effective transport time to the measurement instruments was varied from 11 to 800 seconds to simulate different smoke transport conditions in spacecraft. The resultant aerosol was evaluated by three instruments which measured different moments of the particle size distribution. These moment diagnostics were used to determine the particle number concentration (zeroth moment), the diameter concentration (first moment), and the mass concentration (third moment). These statistics were combined to determine the diameter of average mass and the count mean diameter and by assuming a log-normal distribution, the geometric mean diameter and the geometric standard deviations were also calculated. Smoke particle samples were collected on TEM grids using a thermal precipitator for post flight analysis. The TEM grids were analyzed to determine the particle morphology and shape parameters. The different materials produced particles with significantly different morphologies. Overall the majority of the average smoke particle sizes were found to be in the 200 to 400 nanometer range with the quiescent cases and the cases with increased transport time typically producing with substantially larger particles. The results varied between materials but the smoke particles produced in low gravity were typically twice the size of particles produced in normal gravity. These results can be used to establish design requirements for future spacecraft smoke detectors.
Reducing Individual Variation for fMRI Studies in Children by Minimizing Template Related Errors
Weng, Jian; Dong, Shanshan; He, Hongjian; Chen, Feiyan; Peng, Xiaogang
2015-01-01
Spatial normalization is an essential process for group comparisons in functional MRI studies. In practice, there is a risk of normalization errors particularly in studies involving children, seniors or diseased populations and in regions with high individual variation. One way to minimize normalization errors is to create a study-specific template based on a large sample size. However, studies with a large sample size are not always feasible, particularly for children studies. The performance of templates with a small sample size has not been evaluated in fMRI studies in children. In the current study, this issue was encountered in a working memory task with 29 children in two groups. We compared the performance of different templates: a study-specific template created by the experimental population, a Chinese children template and the widely used adult MNI template. We observed distinct differences in the right orbitofrontal region among the three templates in between-group comparisons. The study-specific template and the Chinese children template were more sensitive for the detection of between-group differences in the orbitofrontal cortex than the MNI template. Proper templates could effectively reduce individual variation. Further analysis revealed a correlation between the BOLD contrast size and the norm index of the affine transformation matrix, i.e., the SFN, which characterizes the difference between a template and a native image and differs significantly across subjects. Thereby, we proposed and tested another method to reduce individual variation that included the SFN as a covariate in group-wise statistics. This correction exhibits outstanding performance in enhancing detection power in group-level tests. A training effect of abacus-based mental calculation was also demonstrated, with significantly elevated activation in the right orbitofrontal region that correlated with behavioral response time across subjects in the trained group. PMID:26207985
The Army Communications Objectives Measurement System (ACOMS): Survey Design
1988-04-01
monthly basis so that the annual sample includes sufficient Hispanics to detect at the .80 power level: (1) Year-to-year changes of 3% in item...Hispanics. The requirements are listed in terms of power level and must be translated into requisite sample sizes. The requirements are expressed as the...annual samples needed to detect certain differences at the 80% power level. Differences in both directions are to be examined, so that a two-tailed
NASA Astrophysics Data System (ADS)
D'Addabbo, M.; Sulpizio, R.; Guidi, M.; Capitani, G.; Mantecca, P.; Zanchetta, G.
2015-12-01
Leaching experiments were carried out on fresh ash samples from Popocatépetl 2012, Etna 2011, and Etna 2012 eruptions, in order to investigate the release of compounds in both double-deionized and lake (Lake Ohrid, FYR of Macedonia) waters. The experiments were carried out using different grain sizes and variable stirring times (from 30 min to 7 days). Results were discussed in the light of changing pH and release of compounds for the different leachates. In particular, Etna samples induced alkalinization, and Popocatépetl samples induced acidification of the corresponding leachates. The release of different elements does not show correlation with the stirring time, with the measured maximum concentrations reached in the first hours of washing. General inverse correlation with grain size was observed only for Na+, K+, Cl-, Ca2+, Mg2+, SO42-, and Mn2+, while the other analysed elements show a complex, scattering relationship with grain size. Geochemical modelling highlights leachates' saturation only for F and Si, with Popocatépetl samples sometimes showing saturation in Fe. The analysed leachates are classified as undrinkable for humans on the basis of European laws, due to excess in F-, Mn2+, Fe, and SO42- (the latter only for Popocatépetl samples). Finally, the Etna 2012 and Popocatépetl leachates were used for toxicity experiments on living biota (Xenopus laevis). They are mildly toxic, and no significant differences exist between the toxic profiles of the two leachates. In particular, no significant embryo mortality was observed; while even at high dilutions, the leachates produced more than 20 % of malformed larvae.
Chase, Jonathan M; Knight, Tiffany M
2013-05-01
There is little consensus about how natural (e.g. productivity, disturbance) and anthropogenic (e.g. invasive species, habitat destruction) ecological drivers influence biodiversity. Here, we show that when sampling is standardised by area (species density) or individuals (rarefied species richness), the measured effect sizes depend critically on the spatial grain and extent of sampling, as well as the size of the species pool. This compromises comparisons of effects sizes within studies using standard statistics, as well as among studies using meta-analysis. To derive an unambiguous effect size, we advocate that comparisons need to be made on a scale-independent metric, such as Hurlbert's Probability of Interspecific Encounter. Analyses of this metric can be used to disentangle the relative influence of changes in the absolute and relative abundances of individuals, as well as their intraspecific aggregations, in driving differences in biodiversity among communities. This and related approaches are necessary to achieve generality in understanding how biodiversity responds to ecological drivers and will necessitate a change in the way many ecologists collect and analyse their data. © 2013 John Wiley & Sons Ltd/CNRS.
Is body size important? Seasonal changes in morphology in two grass-feeding Abacarus mites
USDA-ARS?s Scientific Manuscript database
Overwintering strategies in herbivorous mites (Acari: Eriophyoidea) are poorly understood. A study of two Abacarus spp., was conducted to compare body size parameters of adult females in different seasons. Mites of Abacarus n. sp. (under description) and A. lolli were sampled from Bromopsis inermis ...
Bed-sediment grain-size and morphologic data from Suisun, Grizzly, and Honker Bays, CA, 1998-2002
Hampton, Margaret A.; Snyder, Noah P.; Chin, John L.; Allison, Dan W.; Rubin, David M.
2003-01-01
The USGS Place Based Studies Program for San Francisco Bay investigates this sensitive estuarine system to aid in resource management. As part of the inter-disciplinary research program, the USGS collected side-scan sonar data and bed-sediment samples from north San Francisco Bay to characterize bed-sediment texture and investigate temporal trends in sedimentation. The study area is located in central California and consists of Suisun Bay, and Grizzly and Honker Bays, sub-embayments of Suisun Bay. During the study (1998-2002), the USGS collected three side-scan sonar data sets and approximately 300 sediment samples. The side-scan data revealed predominantly fine-grained material on the bayfloor. We also mapped five different bottom types from the data set, categorized as featureless, furrows, sand waves, machine-made, and miscellaneous. We performed detailed grain-size and statistical analyses on the sediment samples. Overall, we found that grain size ranged from clay to fine sand, with the coarsest material in the channels and finer material located in the shallow bays. Grain-size analyses revealed high spatial variability in size distributions in the channel areas. In contrast, the shallow regions exhibited low spatial variability and consistent sediment size over time.
Measurement of Vibrated Bulk Density of Coke Particle Blends Using Image Texture Analysis
NASA Astrophysics Data System (ADS)
Azari, Kamran; Bogoya-Forero, Wilinthon; Duchesne, Carl; Tessier, Jayson
2017-09-01
A rapid and nondestructive machine vision sensor was developed for predicting the vibrated bulk density (VBD) of petroleum coke particles based on image texture analysis. It could be used for making corrective adjustments to a paste plant operation to reduce green anode variability (e.g., changes in binder demand). Wavelet texture analysis (WTA) and gray level co-occurrence matrix (GLCM) algorithms were used jointly for extracting the surface textural features of coke aggregates from images. These were correlated with the VBD using partial least-squares (PLS) regression. Coke samples of several sizes and from different sources were used to test the sensor. Variations in the coke surface texture introduced by coke size and source allowed for making good predictions of the VBD of individual coke samples and mixtures of them (blends involving two sources and different sizes). Promising results were also obtained for coke blends collected from an industrial-baked carbon anode manufacturer.
Characterisation of Fine Ash Fractions from the AD 1314 Kaharoa Eruption
NASA Astrophysics Data System (ADS)
Weaver, S. J.; Rust, A.; Carey, R. J.; Houghton, B. F.
2012-12-01
The AD 1314±12 yr Kaharoa eruption of Tarawera volcano, New Zealand, produced deposits exhibiting both plinian and subplinian characteristics (Nairn et al., 2001; 2004, Leonard et al., 2002, Hogg et al., 2003). Their widespread dispersal yielded volumes, column heights, and mass discharge rates of plinian magnitude and intensity (Sahetapy-Engel, 2002); however, vertical shifts in grain size suggest waxing and waning within single phases and time-breaks on the order of hours between phases. These grain size shifts were quantified using sieve, laser diffraction, and image analysis of the fine ash fractions (<1 mm in diameter) of some of the most explosive phases of the eruption. These analyses served two purposes: 1) to characterise the change in eruption intensity over time, and 2) to compare the three methods of grain size analysis. Additional analyses of the proportions of components and particle shape were also conducted to aid in the interpretation of the eruption and transport dynamics. 110 samples from a single location about 6 km from source were sieved at half phi intervals between -4φ to 4φ (16 mm - 63 μm). A single sample was then chosen to test the range of grain sizes to run through the Mastersizer 2000. Three aliquots were tested; the first consisted of each sieve size fraction ranging between 0φ (1000 μm) and <4φ (<63 μm, i.e. the pan). For example, 0, 0.5, 1, …, 4φ, and the pan were ran through the Mastersizer and then their results, weighted according to their sieve weight percents, were summed together to produce a total distribution. The second aliquot included 3 samples ranging between 0-2φ (1000-250 μm), 2.5-4φ (249-63 μm), and the pan. A single sample consisting of the total range of grain sizes between 0φ and the pan was used for the final aliquot. Their results were compared and it was determined that the single sample consisting of the broadest range of grain sizes yielded an accurate grain size distribution. This data was then compared with the sieve weight percent data, and revealed that there is a significant difference in size characterisation between sieving and the Mastersizer for size fractions between 0-3φ (1000-125 μm). This is due predominantly to the differing methods that sieving and the Mastersizer use to characterise a single particle, to inhomogeneity in grain density in each grain-size fraction, and to grain-shape irregularities. This led the Mastersizer to allocate grains from a certain sieve size fraction into coarser size fractions. Therefore, only the Mastersizer data from 3.5φ and below were combined with the coarser sieve data to yield total grain size distributions. This high-resolution analysis of the grain size data enabled subtle trends in grain size to be identified and related to short timescale eruptive processes.
Electrofishing effort requirements for estimating species richness in the Kootenai River, Idaho
Watkins, Carson J.; Quist, Michael C.; Shepard, Bradley B.; Ireland, Susan C.
2016-01-01
This study was conducted on the Kootenai River, Idaho to provide insight on sampling requirements to optimize future monitoring effort associated with the response of fish assemblages to habitat rehabilitation. Our objective was to define the electrofishing effort (m) needed to have a 95% probability of sampling 50, 75, and 100% of the observed species richness and to evaluate the relative influence of depth, velocity, and instream woody cover on sample size requirements. Sidechannel habitats required more sampling effort to achieve 75 and 100% of the total species richness than main-channel habitats. The sampling effort required to have a 95% probability of sampling 100% of the species richness was 1100 m for main-channel sites and 1400 m for side-channel sites. We hypothesized that the difference in sampling requirements between main- and side-channel habitats was largely due to differences in habitat characteristics and species richness between main- and side-channel habitats. In general, main-channel habitats had lower species richness than side-channel habitats. Habitat characteristics (i.e., depth, current velocity, and woody instream cover) were not related to sample size requirements. Our guidelines will improve sampling efficiency during monitoring effort in the Kootenai River and provide insight on sampling designs for other large western river systems where electrofishing is used to assess fish assemblages.
Heinz, Marlen; Zak, Dominik
2018-03-01
This study aimed to evaluate the effects of freezing and cold storage at 4 °C on bulk dissolved organic carbon (DOC) and nitrogen (DON) concentration and SEC fractions determined with size exclusion chromatography (SEC), as well as on spectral properties of dissolved organic matter (DOM) analyzed with fluorescence spectroscopy. In order to account for differences in DOM composition and source we analyzed storage effects for three different sample types, including a lake water sample representing freshwater DOM, a leaf litter leachate of Phragmites australis representing a terrestrial, 'fresh' DOM source and peatland porewater samples. According to our findings one week of cold storage can bias DOC and DON determination. Overall, the determination of DOC and DON concentration with SEC analysis for all three sample types were little susceptible to alterations due to freezing. The findings derived for the sampling locations investigated here may not apply for other sampling locations and/or sample types. However, DOC size fractions and DON concentration of formerly frozen samples should be interpreted with caution when sample concentrations are high. Alteration of some optical properties (HIX and SUVA 254 ) due to freezing were evident, and therefore we recommend immediate analysis of samples for spectral analysis. Copyright © 2017 Elsevier Ltd. All rights reserved.
Gomez Baquero, David; Koppel, Kadri; Chambers, Delores; Hołda, Karolina; Głogowski, Robert; Chambers, Edgar
2018-05-23
Sensory analysis of pet foods has been emerging as an important field of study for the pet food industry over the last few decades. Few studies have been conducted on understanding the pet owners’ perception of pet foods. The objective of this study is to gain a deeper understanding on the perception of the visual characteristics of dry dog foods by dog owners in different consumer segments. A total of 120 consumers evaluated the appearance of 30 dry dog food samples with varying visual characteristics. The consumers rated the acceptance of the samples and associated each one with a list of positive and negative beliefs. Cluster Analysis, ANOVA and Correspondence Analysis were used to analyze the consumer responses. The acceptability of the appearance of dry dog foods was affected by the number of different kibbles present, color(s), shape(s), and size(s) of the kibbles in the product. Three consumer clusters were identified. Consumers rated highest single-kibble samples of medium sizes, traditional shapes, and brown colors. Participants disliked extra-small or extra-large kibble sizes, shapes with high-dimensional contrast, and kibbles of light brown color. These findings can help dry dog food manufacturers to meet consumers’ needs with increasing benefits to the pet food and commodity industries.
Life history dependent morphometric variation in stream-dwelling Atlantic salmon
Letcher, B.H.
2003-01-01
The time course of morphometric variation among life histories for stream-dwelling Atlantic salmon (Salmo salar L.) parr (age-0+ to age-2+) was analyzed. Possible life histories were combinations of parr maturity status in the autumn (mature or immature) and age at outmigration (smolt at age-2+ or later age). Actual life histories expressed with enough fish for analysis in the 1997 cohort were immature/age-2+ smolt, mature/age-2 +smolt, and mature/age-2+ non-smolt. Tagged fish were assigned to one of the three life histories and digital pictures from the field were analyzed using landmark-based geometric morphometrics. Results indicated that successful grouping of fish according to life history varied with fish age, but that fish could be grouped before the actual expression of the life histories. By March (age-1+), fish were successfully grouped using a descriptive discriminant function and successful assignment ranged from 84 to 97% for the remainder of stream residence. A jackknife of the discriminant function revealed an average life history prediction success of 67% from age-1+ summer to smolting. Low sample numbers for one of the life histories may have limited prediction success. A MANOVA on the shape descriptors (relative warps) also indicated significant differences in shape among life histories from age-1+ summer through to smolting. Across all samples, shape varied significantly with size. Within samples, shape did not vary significantly with size for samples from December (age-0+) to May (age-1+). During the age-1+ summer however, shape varied significantly with size, but the relationship between shape and size was not different among life histories. In the autumn (age-1+) and winter (age-2+), life history differences explained a significant portion of the change in shape with size. Life history dependent morphometric variation may be useful to indicate the timing of early expressions of life history variation and as a tool to explore temporal and spatial variation in life history expression.
Mesh-size effects on drift sample composition as determined with a triple net sampler
Slack, K.V.; Tilley, L.J.; Kennelly, S.S.
1991-01-01
Nested nets of three different mesh apertures were used to study mesh-size effects on drift collected in a small mountain stream. The innermost, middle, and outermost nets had, respectively, 425 ??m, 209 ??m and 106 ??m openings, a design that reduced clogging while partitioning collections into three size groups. The open area of mesh in each net, from largest to smallest mesh opening, was 3.7, 5.7 and 8.0 times the area of the net mouth. Volumes of filtered water were determined with a flowmeter. The results are expressed as (1) drift retained by each net, (2) drift that would have been collected by a single net of given mesh size, and (3) the percentage of total drift (the sum of the catches from all three nets) that passed through the 425 ??m and 209 ??m nets. During a two day period in August 1986, Chironomidae larvae were dominant numerically in all 209 ??m and 106 ??m samples and midday 425 ??m samples. Large drifters (Ephemerellidae) occurred only in 425 ??m or 209 ??m nets, but the general pattern was an increase in abundance and number of taxa with decreasing mesh size. Relatively more individuals occurred in the larger mesh nets at night than during the day. The two larger mesh sizes retained 70% of the total sediment/detritus in the drift collections, and this decreased the rate of clogging of the 106 ??m net. If an objective of a sampling program is to compare drift density or drift rate between areas or sampling dates, the same mesh size should be used for all sample collection and processing. The mesh aperture used for drift collection should retain all species and life stages of significance in a study. The nested net design enables an investigator to test the adequacy of drift samples. ?? 1991 Kluwer Academic Publishers.
Micro Electron MicroProbe and Sample Analyzer
NASA Technical Reports Server (NTRS)
Manohara, Harish; Bearman, Gregory; Douglas, Susanne; Bronikowski, Michael; Urgiles, Eduardo; Kowalczyk, Robert; Bryson, Charles
2009-01-01
A proposed, low-power, backpack-sized instrument, denoted the micro electron microprobe and sample analyzer (MEMSA), would serve as a means of rapidly performing high-resolution microscopy and energy-dispersive x-ray spectroscopy (EDX) of soil, dust, and rock particles in the field. The MEMSA would be similar to an environmental scanning electron microscope (ESEM) but would be much smaller and designed specifically for field use in studying effects of geological alteration at the micrometer scale. Like an ESEM, the MEMSA could be used to examine uncoated, electrically nonconductive specimens. In addition to the difference in size, other significant differences between the MEMSA and an ESEM lie in the mode of scanning and the nature of the electron source.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anandakumar, U.; Webb, J.E.; Singh, R.N.
The matrix cracking behavior of a zircon matrix - uniaxial SCS 6 fiber composite was studied as a function of initial flaw size and temperature. The composites were fabricated by a tape casting and hot pressing technique. Surface flaws of controlled size were introduced using a vicker`s indenter. The composite samples were tested in three point flexure at three different temperatures to study the non steady state and steady state matrix cracking behavior. The composite samples exhibited steady state and non steady matrix cracking behavior at all temperatures. The steady state matrix cracking stress and steady state crack size increasedmore » with increasing temperature. The results of the study correlated well with the results predicted by the matrix cracking models.« less
Spatial Sampling of Weather Data for Regional Crop Yield Simulations
NASA Technical Reports Server (NTRS)
Van Bussel, Lenny G. J.; Ewert, Frank; Zhao, Gang; Hoffmann, Holger; Enders, Andreas; Wallach, Daniel; Asseng, Senthold; Baigorria, Guillermo A.; Basso, Bruno; Biernath, Christian;
2016-01-01
Field-scale crop models are increasingly applied at spatio-temporal scales that range from regions to the globe and from decades up to 100 years. Sufficiently detailed data to capture the prevailing spatio-temporal heterogeneity in weather, soil, and management conditions as needed by crop models are rarely available. Effective sampling may overcome the problem of missing data but has rarely been investigated. In this study the effect of sampling weather data has been evaluated for simulating yields of winter wheat in a region in Germany over a 30-year period (1982-2011) using 12 process-based crop models. A stratified sampling was applied to compare the effect of different sizes of spatially sampled weather data (10, 30, 50, 100, 500, 1000 and full coverage of 34,078 sampling points) on simulated wheat yields. Stratified sampling was further compared with random sampling. Possible interactions between sample size and crop model were evaluated. The results showed differences in simulated yields among crop models but all models reproduced well the pattern of the stratification. Importantly, the regional mean of simulated yields based on full coverage could already be reproduced by a small sample of 10 points. This was also true for reproducing the temporal variability in simulated yields but more sampling points (about 100) were required to accurately reproduce spatial yield variability. The number of sampling points can be smaller when a stratified sampling is applied as compared to a random sampling. However, differences between crop models were observed including some interaction between the effect of sampling on simulated yields and the model used. We concluded that stratified sampling can considerably reduce the number of required simulations. But, differences between crop models must be considered as the choice for a specific model can have larger effects on simulated yields than the sampling strategy. Assessing the impact of sampling soil and crop management data for regional simulations of crop yields is still needed.
Penton, C. Ryan; Gupta, Vadakattu V. S. R.; Yu, Julian; Tiedje, James M.
2016-01-01
We examined the effect of different soil sample sizes obtained from an agricultural field, under a single cropping system uniform in soil properties and aboveground crop responses, on bacterial and fungal community structure and microbial diversity indices. DNA extracted from soil sample sizes of 0.25, 1, 5, and 10 g using MoBIO kits and from 10 and 100 g sizes using a bead-beating method (SARDI) were used as templates for high-throughput sequencing of 16S and 28S rRNA gene amplicons for bacteria and fungi, respectively, on the Illumina MiSeq and Roche 454 platforms. Sample size significantly affected overall bacterial and fungal community structure, replicate dispersion and the number of operational taxonomic units (OTUs) retrieved. Richness, evenness and diversity were also significantly affected. The largest diversity estimates were always associated with the 10 g MoBIO extractions with a corresponding reduction in replicate dispersion. For the fungal data, smaller MoBIO extractions identified more unclassified Eukaryota incertae sedis and unclassified glomeromycota while the SARDI method retrieved more abundant OTUs containing unclassified Pleosporales and the fungal genera Alternaria and Cercophora. Overall, these findings indicate that a 10 g soil DNA extraction is most suitable for both soil bacterial and fungal communities for retrieving optimal diversity while still capturing rarer taxa in concert with decreasing replicate variation. PMID:27313569
Online versus offline: The Web as a medium for response time data collection.
Chetverikov, Andrey; Upravitelev, Philipp
2016-09-01
The Internet provides a convenient environment for data collection in psychology. Modern Web programming languages, such as JavaScript or Flash (ActionScript), facilitate complex experiments without the necessity of experimenter presence. Yet there is always a question of how much noise is added due to the differences between the setups used by participants and whether it is compensated for by increased ecological validity and larger sample sizes. This is especially a problem for experiments that measure response times (RTs), because they are more sensitive (and hence more susceptible to noise) than, for example, choices per se. We used a simple visual search task with different set sizes to compare laboratory performance with Web performance. The results suggest that although the locations (means) of RT distributions are different, other distribution parameters are not. Furthermore, the effect of experiment setting does not depend on set size, suggesting that task difficulty is not important in the choice of a data collection method. We also collected an additional online sample to investigate the effects of hardware and software diversity on the accuracy of RT data. We found that the high diversity of browsers, operating systems, and CPU performance may have a detrimental effect, though it can partly be compensated for by increased sample sizes and trial numbers. In sum, the findings show that Web-based experiments are an acceptable source of RT data, comparable to a common keyboard-based setup in the laboratory.
Synthesis and characterization of silicon nanorod on n-type porous silicon.
Behzad, Kasra; Mat Yunus, Wan Mahmood; Bahrami, Afarin; Kharazmi, Alireza; Soltani, Nayereh
2016-03-20
This work reports a new method for growing semiconductor nanorods on a porous silicon substrate. After preparation of n-type porous silicon samples, a thin layer of gold was deposited on them. Gold deposited samples were annealed at different temperatures. The structural, thermal, and optical properties of the samples were studied using a field emission scanning electron microscope (FESEM), photoacoustic spectroscopy, and photoluminescence spectroscopy, respectively. FESEM analysis revealed that silicon nanorods of different sizes grew on the annealed samples. Thermal behavior of the samples was studied using photoacoustic spectroscopy. Photoluminescence spectroscopy showed that the emission peaks were degraded by gold deposition and attenuated for all samples by annealing.
Baez, Sandra; Flichtentrei, Daniel; Prats, María; Mastandueno, Ricardo; García, Adolfo M; Cetkovich, Marcelo; Ibáñez, Agustín
2017-01-01
Research on sex differences in empathy has revealed mixed findings. Whereas experimental and neuropsychological measures show no consistent sex effect, self-report data consistently indicates greater empathy in women. However, available results mainly come from separate populations with relatively small samples, which may inflate effect sizes and hinder comparability between both empirical corpora. To elucidate the issue, we conducted two large-scale studies. First, we examined whether sex differences emerge in a large population-based sample (n = 10,802) when empathy is measured with an experimental empathy-for-pain paradigm. Moreover, we investigated the relationship between empathy and moral judgment. In the second study, a subsample (n = 334) completed a self-report empathy questionnaire. Results showed some sex differences in the experimental paradigm, but with minuscule effect sizes. Conversely, women did portray themselves as more empathic through self-reports. In addition, utilitarian responses to moral dilemmas were less frequent in women, although these differences also had small effect sizes. These findings suggest that sex differences in empathy are highly driven by the assessment measure. In particular, self-reports may induce biases leading individuals to assume gender-role stereotypes. Awareness of the role of measurement instruments in this field may hone our understanding of the links between empathy, sex differences, and gender roles.
Mixing problems in using indicators for measuring regional blood flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ushioda, E.; Nuwayhid, B.; Tabsh, K.
A basic requirement for using indicators for measuring blood flow is adequate mixing of the indicator with blood prior to sampling the site. This requirement has been met by depositing the indicator in the heart and sampling from an artery. Recently, authors have injected microspheres into veins and sampled from venous sites. The present studies were designed to investigate the mixing problems in sheep and rabbits by means of Cardio-Green and labeled microspheres. The indicators were injected at different points in the circulatory system, and blood was sampled at different levels of the venous and arterial systems. Results show themore » following: (a) When an indicator of small molecular size (Cardio-Green) is allowed to pass through the heart chambers, adequate mixing is achieved, yielding accurate and reproducible results. (b) When any indicator (Cardio-Green or microspheres) is injected into veins, and sampling is done at any point in the venous system, mixing is inadequate, yielding flow results which are inconsistent and erratic. (c) For an indicator or large molecular size (microspheres), injecting into the left side of the heart and sampling from arterial sites yield accurate and reproducible results regardless of whether blood is sampled continuously or intermittently.« less
Boessen, Ruud; van der Baan, Frederieke; Groenwold, Rolf; Egberts, Antoine; Klungel, Olaf; Grobbee, Diederick; Knol, Mirjam; Roes, Kit
2013-01-01
Two-stage clinical trial designs may be efficient in pharmacogenetics research when there is some but inconclusive evidence of effect modification by a genomic marker. Two-stage designs allow to stop early for efficacy or futility and can offer the additional opportunity to enrich the study population to a specific patient subgroup after an interim analysis. This study compared sample size requirements for fixed parallel group, group sequential, and adaptive selection designs with equal overall power and control of the family-wise type I error rate. The designs were evaluated across scenarios that defined the effect sizes in the marker positive and marker negative subgroups and the prevalence of marker positive patients in the overall study population. Effect sizes were chosen to reflect realistic planning scenarios, where at least some effect is present in the marker negative subgroup. In addition, scenarios were considered in which the assumed 'true' subgroup effects (i.e., the postulated effects) differed from those hypothesized at the planning stage. As expected, both two-stage designs generally required fewer patients than a fixed parallel group design, and the advantage increased as the difference between subgroups increased. The adaptive selection design added little further reduction in sample size, as compared with the group sequential design, when the postulated effect sizes were equal to those hypothesized at the planning stage. However, when the postulated effects deviated strongly in favor of enrichment, the comparative advantage of the adaptive selection design increased, which precisely reflects the adaptive nature of the design. Copyright © 2013 John Wiley & Sons, Ltd.
Simulation of parametric model towards the fixed covariate of right censored lung cancer data
NASA Astrophysics Data System (ADS)
Afiqah Muhamad Jamil, Siti; Asrul Affendi Abdullah, M.; Kek, Sie Long; Ridwan Olaniran, Oyebayo; Enera Amran, Syahila
2017-09-01
In this study, simulation procedure was applied to measure the fixed covariate of right censored data by using parametric survival model. The scale and shape parameter were modified to differentiate the analysis of parametric regression survival model. Statistically, the biases, mean biases and the coverage probability were used in this analysis. Consequently, different sample sizes were employed to distinguish the impact of parametric regression model towards right censored data with 50, 100, 150 and 200 number of sample. R-statistical software was utilised to develop the coding simulation with right censored data. Besides, the final model of right censored simulation was compared with the right censored lung cancer data in Malaysia. It was found that different values of shape and scale parameter with different sample size, help to improve the simulation strategy for right censored data and Weibull regression survival model is suitable fit towards the simulation of survival of lung cancer patients data in Malaysia.
Early-type galaxies: mass-size relation at z ˜ 1.3 for different environments
NASA Astrophysics Data System (ADS)
Raichoor, A.; Mei, S.; Stanford, S. A.; Holden, B. P.; Nakata, F.; Rosati, P.; Shankar, F.; Tanaka, M.; Ford, H.; Huertas-Company, M.; Illingworth, G.; Kodama, T.; Postman, M.; Rettura, A.; Blakeslee, J. P.; Demarco, R.; Jee, M. J.; White, R. L.
2011-12-01
We combine multi-wavelength data of the Lynx superstructure and GOODS/CDF-S to build a sample of 75 visually selected early-type galaxies (ETGs), spanning different environments (cluster/group/field) at z ˜ 1.3. By estimating their mass, age (SED fitting, with a careful attention to the stellar population model used) and size, we are able to probe the dependence on the environment of the mass-size relation. We find that, for ETGs with 10^{10} < M / M_⊙ < 10^{11.5}, (1) the mass-size relation in the field did not evolve overall from z ˜ 1.3 to present; (2) the mass-size relation in cluster/group environments at z ˜ 1.3 lies at smaller sizes than the local mass-size relation (R_{e,z ˜ 1.3}/R_{e,z = 0} ˜ 0.6-0.8).
A size-dependent constitutive model of bulk metallic glasses in the supercooled liquid region
Yao, Di; Deng, Lei; Zhang, Mao; Wang, Xinyun; Tang, Na; Li, Jianjun
2015-01-01
Size effect is of great importance in micro forming processes. In this paper, micro cylinder compression was conducted to investigate the deformation behavior of bulk metallic glasses (BMGs) in supercooled liquid region with different deformation variables including sample size, temperature and strain rate. It was found that the elastic and plastic behaviors of BMGs have a strong dependence on the sample size. The free volume and defect concentration were introduced to explain the size effect. In order to demonstrate the influence of deformation variables on steady stress, elastic modulus and overshoot phenomenon, four size-dependent factors were proposed to construct a size-dependent constitutive model based on the Maxwell-pulse type model previously presented by the authors according to viscosity theory and free volume model. The proposed constitutive model was then adopted in finite element method simulations, and validated by comparing the micro cylinder compression and micro double cup extrusion experimental data with the numerical results. Furthermore, the model provides a new approach to understanding the size-dependent plastic deformation behavior of BMGs. PMID:25626690
Lexical development in Korean: vocabulary size, lexical composition, and late talking.
Rescorla, Leslie; Lee, Youn Mi Cathy; Lee, Youn Min Cathy; Oh, Kyung Ja; Kim, Young Ah
2013-04-01
In this study, the authors aimed to compare vocabulary size, lexical composition, and late talking in large samples of Korean and U.S. children ages 18-35 months. Data for 2,191 Korean children (211 children recruited "offline" through preschools, and 1,980 recruited "online" via the Internet) and 274 U.S. children were obtained using the Language Development Survey (LDS). Mean vocabulary size was slightly larger in the offline than the online group, but the groups were acquiring almost identical words. Mean vocabulary size did not differ by country; girls and older children had larger vocabularies in both countries. The Korean-U.S. Q correlations for percentage use of LDS words (.53 and .56) indicated considerable concordance across countries in lexical composition. Noun dominance was as large in Korean lexicons as in U.S. lexicons. About half of the most commonly reported words for the Korean and U.S. children were identical. Lexicons of late talkers resembled those of typically developing younger children in the same sample. Despite linguistic and discourse differences between Korean and English, LDS findings indicated considerable cross-linguistic similarity with respect to vocabulary size, lexical composition, and late talking.
Relation Between Pore Size and the Compressibility of a Confined Fluid
Gor, Gennady Y.; Siderius, Daniel W.; Rasmussen, Christopher J.; Krekelberg, William P.; Shen, Vincent K.; Bernstein, Noam
2015-01-01
When a fluid is confined to a nanopore, its thermodynamic properties differ from the properties of a bulk fluid, so measuring such properties of the confined fluid can provide information about the pore sizes. Here we report a simple relation between the pore size and isothermal compressibility of argon confined in these pores. Compressibility is calculated from the fluctuations of the number of particles in the grand canonical ensemble using two different simulation techniques: conventional grand-canonical Monte Carlo and grand-canonical ensemble transition-matrix Monte Carlo. Our results provide a theoretical framework for extracting the information on the pore sizes of fluid-saturated samples by measuring the compressibility from ultrasonic experiments. PMID:26590541
NASA Astrophysics Data System (ADS)
Yu, M.; Eglinton, T. I.; Haghipour, N.; Montluçon, D. B.; Wacker, L.; Hou, P.; Zhao, M.
2016-12-01
The transport of organic carbon (OC) by rivers to coastal oceans is an important component of the global carbon cycle. The Yellow River (YR), the second largest river in China, transports large amounts of particulate organic carbon (POC) to the Chinese marginal seas, with fossil and pre-aged (ca, 1600 yr) OC comprising the dominant components. However, the influence of hydrodynamic processes on the origin, composition and age of POC exported by the YR remains poorly understood, yet these processes likely ultimately play an important role in determining OC fate in the Chinese marginal seas. We address this question through bulk, biomarker and carbon isotopic (δ13C and Δ14C) characterization of organic matter associated with different grain size fractions of total suspended particles (TSP) in the YR. Surface TSP samples were collected in the spring, summer, fall and during the Water-Sediment Regulation period (WSR, July) of 2015. TSP samples were separated into five grain-size fractions (<8μm, 8-16μm, 16-32μm, 32-63μm and >63μm) for organic geochemical and isotope analysis. Generally, the 16-32 and 32-63μm fractions contributed most of the TSP mass and the majority of OC resided in 16-32μm fraction. TOC% decreased with increasing grain size and 14C ages exhibited significant variability, ranging from 3,335 yr (<8μm fraction in summer) to 11,120 yr (>63μm fraction in autumn), but did not show any systematic trend among grain size fractions or across sampling times. In contrast, compound-specific 14C analysis of long-chain n-fatty acids (C26-30 FAs) revealed two clear patterns: first, C26-30 FAs age decreased with increasing grain size for all sampling times; second, the C26-30 FAs age difference was the largest among the different size fractions during the WSR period, and smallest after the WSR. These findings have important implications for our understanding of riverine POC transport mechanisms and their influence on the dispersal and burial efficiency of terrestrial OC in coastal oceans.
NASA Astrophysics Data System (ADS)
Beck, Melanie; Scarlata, Claudia; Fortson, Lucy; Willett, Kyle; Galloway, Melanie
2016-01-01
It is well known that the mass-size distribution evolves as a function of cosmic time and that this evolution is different between passive and star-forming galaxy populations. However, the devil is in the details and the precise evolution is still a matter of debate since this requires careful comparison between similar galaxy populations over cosmic time while simultaneously taking into account changes in image resolution, rest-frame wavelength, and surface brightness dimming in addition to properly selecting representative morphological samples.Here we present the first step in an ambitious undertaking to calculate the bivariate mass-size distribution as a function of time and morphology. We begin with a large sample (~3 x 105) of SDSS galaxies at z ~ 0.1. Morphologies for this sample have been determined by Galaxy Zoo crowdsourced visual classifications and we split the sample not only by disk- and bulge-dominated galaxies but also in finer morphology bins such as bulge strength. Bivariate distribution functions are the only way to properly account for biases and selection effects. In particular, we quantify the mass-size distribution with a version of the parametric Maximum Likelihood estimator which has been modified to account for measurement errors as well as upper limits on galaxy sizes.
Hewett, P
1995-02-01
Particle size distributions were measured for fumes from mild steel (MS) and stainless steel (SS); shielded metal arc welding (SMAW) and gas metal arc welding (GMAW) consumables. Up to six samples of each type of fume were collected in a test chamber using a micro-orifice uniform deposit (cascade) impactor. Bulk samples were collected for bulk fume density and specific surface area analysis. Additional impactor samples were collected using polycarbonate substrates and analyzed for elemental content. The parameters of the underlying mass distributions were estimated using a nonlinear least squares analysis method that fits a smooth curve to the mass fraction distribution histograms of all samples for each type of fume. The mass distributions for all four consumables were unimodal and well described by a lognormal distribution; with the exception of the GMAW-MS and GMAW-SS comparison, they were statistically different. The estimated mass distribution geometric means for the SMAW-MS and SMAW-SS consumables were 0.59 and 0.46 micron aerodynamic equivalent diameter (AED), respectively, and 0.25 micron AED for both the GMAW-MS and GMAW-SS consumables. The bulk fume densities and specific surface areas were similar for the SMAW-MS and SMAW-SS consumables and for the GMAW-MS and GMAW-SS consumables, but differed between SMAW and GMAW. The distribution of metals was similar to the mass distributions. Particle size distributions and physical properties of the fumes were considerably different when categorized by welding method. Within each welding method there was little difference between MS and SS fumes.
Application-Specific Graph Sampling for Frequent Subgraph Mining and Community Detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Purohit, Sumit; Choudhury, Sutanay; Holder, Lawrence B.
Graph mining is an important data analysis methodology, but struggles as the input graph size increases. The scalability and usability challenges posed by such large graphs make it imperative to sample the input graph and reduce its size. The critical challenge in sampling is to identify the appropriate algorithm to insure the resulting analysis does not suffer heavily from the data reduction. Predicting the expected performance degradation for a given graph and sampling algorithm is also useful. In this paper, we present different sampling approaches for graph mining applications such as Frequent Subgrpah Mining (FSM), and Community Detection (CD). Wemore » explore graph metrics such as PageRank, Triangles, and Diversity to sample a graph and conclude that for heterogeneous graphs Triangles and Diversity perform better than degree based metrics. We also present two new sampling variations for targeted graph mining applications. We present empirical results to show that knowledge of the target application, along with input graph properties can be used to select the best sampling algorithm. We also conclude that performance degradation is an abrupt, rather than gradual phenomena, as the sample size decreases. We present the empirical results to show that the performance degradation follows a logistic function.« less
Moroz, Veronica; Wilson, Jayne S; Kearns, Pamela; Wheatley, Keith
2014-12-10
Historically controlled studies are commonly undertaken in paediatric oncology, despite their potential biases. Our aim was to compare the outcome of the control group in randomised controlled trials (RCTs) in paediatric oncology with those anticipated in the sample size calculations in the protocols. Our rationale was that, had these RCTs been performed as historical control studies instead, the available outcome data used to calculate the sample size in the RCT would have been used as the historical control outcome data. A systematic search was undertaken for published paediatric oncology RCTs using the Cochrane Central Register of Controlled Trials (CENTRAL) database from its inception up to July 2013. Data on sample size assumptions and observed outcomes (timetoevent and proportions) were extracted to calculate differences between randomised and historical control outcomes, and a one-sample t-test was employed to assess whether the difference between anticipated and observed control groups differed from zero. Forty-eight randomised questions were included. The median year of publication was 2005, and the range was from 1976 to 2010. There were 31 superiority and 11 equivalence/noninferiority randomised questions with time-to-event outcomes. The median absolute difference between observed and anticipated control outcomes was 5.0% (range: -23 to +34), and the mean difference was 3.8% (95% CI: +0.57 to +7.0; P = 0.022). Because the observed control group (that is, standard treatment arm) in RCTs performed better than anticipated, we found that historically controlled studies that used similar assumptions for the standard treatment were likely to overestimate the benefit of new treatments, potentially leading to children with cancer being given ineffective therapy that may have additional toxicity.
A comparison of solids collected in sediment traps and automated water samplers
Bartsch, L.A.; Rada, R.G.; Sullivan, J.F.
1996-01-01
Sediment traps are being used in some pollution monitoring programs in the USA to sample suspended solids for contaminant analyses. This monitoring approach assumes that the characteristics of solids obtained in sediment traps are the same as those collected in whole-water sampling devices. We tested this assumption in the upper Mississippi River, based on the inorganic particle-size distribution (determined with a laser particle- analyzer) and volatile matter content of solids (a surrogate for organic matter). Cylindrical sediment traps (aspect ratio 3) were attached to a rigid mooring device and deployed in a flowing side channel in Navigation Pool 7 of the upper Mississippi River. On each side of the mooring device, a trap was situated adjacent to a port of an autosampler that collected raw water samples hourly to form 2-d composite samples. Paired samples (one trap and one raw water, composite sample) were removed from each end of the mooring device at 2-d intervals during the 30-d study period and compared. The relative particle collection efficiency of paired samplers did not vary temporally. Particle-size distributions of inorganic solids from sediment traps and water samples were not significantly different. The volatile matter content of solids was lesser in sediment traps (mean, 9.5%) than in corresponding water samples (mean, 22.7%). This bias may have been partly due to under-collection of phytoplankton (mainly cyanobacteria), which were abundant in the water column during the study. The positioning of water samplers and sediment traps in the mooring device did not influence the particle-size distribution or total solids of samples. We observed a small difference in the amount of organic matter collected by water samplers situated at opposite ends of the mooring device.
Fong, Erika J.; Huang, Chao; Hamilton, Julie; ...
2015-11-23
Here, a major advantage of microfluidic devices is the ability to manipulate small sample volumes, thus reducing reagent waste and preserving precious sample. However, to achieve robust sample manipulation it is necessary to address device integration with the macroscale environment. To realize repeatable, sensitive particle separation with microfluidic devices, this protocol presents a complete automated and integrated microfluidic platform that enables precise processing of 0.15–1.5 ml samples using microfluidic devices. Important aspects of this system include modular device layout and robust fixtures resulting in reliable and flexible world to chip connections, and fully-automated fluid handling which accomplishes closed-loop sample collection,more » system cleaning and priming steps to ensure repeatable operation. Different microfluidic devices can be used interchangeably with this architecture. Here we incorporate an acoustofluidic device, detail its characterization, performance optimization, and demonstrate its use for size-separation of biological samples. By using real-time feedback during separation experiments, sample collection is optimized to conserve and concentrate sample. Although requiring the integration of multiple pieces of equipment, advantages of this architecture include the ability to process unknown samples with no additional system optimization, ease of device replacement, and precise, robust sample processing.« less
Partitioning of habitable pore space in earthworm burrows.
Gorres, Josef H; Amador, Jose A
2010-03-01
Earthworms affect macro-pore structure of soils. However, some studies suggest that earthworm burrow walls and casts themselves differ greatly in structure from surrounding soils, potentially creating habitat for microbivorours nematodes which accelerate the decomposition and C and N mineralization. In this study aggregates were sampled from the burrow walls of the anecic earthworm Lumbricus terrestris and bulk soil (not altered by earthworms) from mesocosm incubated in the lab for 0, 1, 3, 5 and 16 weeks. Pore volumes and pore sizes were measured in triplicate with Mercury Intrusion Porosimetry (MIP). This method is well suited to establish pore size structure in the context of habitat, because it measures the stepwise intrusion of mercury from the outside of the aggregate into ever smaller pores. The progress of mercury into the aggregate interior thus resembles potential paths of a nematode into accessible habitable pore spaces residing in an aggregate. Total specific pore volume, V(s), varied between 0.13 and 0.18 mL/g and increased from 3 to 16 weeks in both burrow and bulk soil. Differences between total V(s) of bulk and burrow samples were not significant on any sampling date. However, differences were significant for pore size fractions at the scale of nematode body diameter.
Partitioning of habitable pore space in earthworm burrows
Amador, Jose A.
2010-01-01
Earthworms affect macro-pore structure of soils. However, some studies suggest that earthworm burrow walls and casts themselves differ greatly in structure from surrounding soils, potentially creating habitat for microbivorours nematodes which accelerate the decomposition and C and N mineralization. In this study aggregates were sampled from the burrow walls of the anecic earthworm Lumbricus terrestris and bulk soil (not altered by earthworms) from mesocosm incubated in the lab for 0, 1, 3, 5 and 16 weeks. Pore volumes and pore sizes were measured in triplicate with Mercury Intrusion Porosimetry (MIP). This method is well suited to establish pore size structure in the context of habitat, because it measures the stepwise intrusion of mercury from the outside of the aggregate into ever smaller pores. The progress of mercury into the aggregate interior thus resembles potential paths of a nematode into accessible habitable pore spaces residing in an aggregate. Total specific pore volume, Vs, varied between 0.13 and 0.18 mL/g and increased from 3 to 16 weeks in both burrow and bulk soil. Differences between total Vs of bulk and burrow samples were not significant on any sampling date. However, differences were significant for pore size fractions at the scale of nematode body diameter. PMID:22736839
Pinto, Colin A; Saripella, Kalyan K; Loka, Nikhil C; Neau, Steven H
2018-04-01
Certain issues with the use of particles of chitosan (Ch) cross-linked with tripolyphosphate (TPP) in sustained release formulations include inefficient drug loading, burst drug release, and incomplete drug release. Acetaminophen was added to Ch:TPP particles to test for advantages of drug addition extragranularly over drug addition made during cross-linking. The influences of Ch concentration, Ch:TPP ratio, temperature, ionic strength, and pH were assessed. Design of experiments allowed identification of factors and 2-factor interactions that have significant effects on average particle size and size distribution, yield, zeta potential, and true density of the particles, as well as drug release from the directly compressed tablets. Statistical model equations directed production of a control batch that minimized span, maximized yield, and targeted a t 50 of 90 min (sample A); sample B that differed by targeting a t 50 of 240-300 min to provide sustained release; and sample C that differed from sample B by maximizing span. Sample B maximized yield and provided its targeted t 50 and the smallest average particle size, with the higher zeta potential and the lower span of samples B and C. Extragranular addition of a drug to Ch:TPP particles achieved 100% drug loading, eliminated a burst drug release, and can accomplish complete drug release. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Equivalent statistics and data interpretation.
Francis, Gregory
2017-08-01
Recent reform efforts in psychological science have led to a plethora of choices for scientists to analyze their data. A scientist making an inference about their data must now decide whether to report a p value, summarize the data with a standardized effect size and its confidence interval, report a Bayes Factor, or use other model comparison methods. To make good choices among these options, it is necessary for researchers to understand the characteristics of the various statistics used by the different analysis frameworks. Toward that end, this paper makes two contributions. First, it shows that for the case of a two-sample t test with known sample sizes, many different summary statistics are mathematically equivalent in the sense that they are based on the very same information in the data set. When the sample sizes are known, the p value provides as much information about a data set as the confidence interval of Cohen's d or a JZS Bayes factor. Second, this equivalence means that different analysis methods differ only in their interpretation of the empirical data. At first glance, it might seem that mathematical equivalence of the statistics suggests that it does not matter much which statistic is reported, but the opposite is true because the appropriateness of a reported statistic is relative to the inference it promotes. Accordingly, scientists should choose an analysis method appropriate for their scientific investigation. A direct comparison of the different inferential frameworks provides some guidance for scientists to make good choices and improve scientific practice.
Size-dependent effects in supported highly dispersed Fe2O3 catalysts, doped with Pt and Pd
NASA Astrophysics Data System (ADS)
Cherkezova-Zheleva, Zara; Shopska, Maya; Mitov, Ivan; Kadinov, Georgi
2010-06-01
Series of Fe and Fe-Me (Me = Pt or Pd) catalyst supported on γ-Al2O3, TiO2 (anatase) or diatomite were prepared by the incipient wetness impregnation method. The metal loading was 8 wt.% Fe and 0.7 wt.% noble metal. The preparation and pretreatment conditions of all studied samples were kept to be the same. X-ray diffraction, Moessbauer spectroscopy, X-ray photoelectron spectroscopy and temperature-programmed reduction are used for characterization of the supports and the samples at different steps during their treatment and catalytic tests. The catalytic activity of the samples was tested in the reaction of total benzene oxidation. The physicochemical and catalytic properties of the obtained materials are compared with respect of the different chemical composition, dispersion of used carriers and of the supported phases. Samples with the same composition prepared by mechanical mixing are studied as catalysts for comparison and for clearing up the presence of size-dependent effect, also.
Lozano-Cortés, Diego F; Berumen, Michael L
2016-04-30
Coral colony size-frequency distributions can be used to assess population responses to local environmental conditions and disturbances. In this study, we surveyed juvenile pocilloporids, herbivorous fish densities, and algal cover in the central and southern Saudi Arabian Red Sea. We sampled nine reefs with different disturbance histories along a north-south natural gradient of physicochemical conditions (higher salinity and wider temperature fluctuations in the north, and higher turbidity and productivity in the south). Since coral populations with negatively skewed size-frequency distributions have been associated with unfavorable environmental conditions, we expected to find more negative distributions in the southern Red Sea, where corals are potentially experiencing suboptimal conditions. Although juvenile coral and parrotfish densities differed significantly between the two regions, mean colony size and size-frequency distributions did not. Results suggest that pocilloporid colony size-frequency distribution may not be an accurate indicator of differences in biological or oceanographic conditions in the Red Sea. Copyright © 2015 Elsevier Ltd. All rights reserved.
Walker, Christopher S; Yapuncich, Gabriel S; Sridhar, Shilpa; Cameron, Noël; Churchill, Steven E
2018-02-01
Body mass is an ecologically and biomechanically important variable in the study of hominin biology. Regression equations derived from recent human samples allow for the reasonable prediction of body mass of later, more human-like, and generally larger hominins from hip joint dimensions, but potential differences in hip biomechanics across hominin taxa render their use questionable with some earlier taxa (i.e., Australopithecus spp.). Morphometric prediction equations using stature and bi-iliac breadth avoid this problem, but their applicability to early hominins, some of which differ in both size and proportions from modern adult humans, has not been demonstrated. Here we use mean stature, bi-iliac breadth, and body mass from a global sample of human juveniles ranging in age from 6 to 12 years (n = 530 age- and sex-specific group annual means from 33 countries/regions) to evaluate the accuracy of several published morphometric prediction equations when applied to small humans. Though the body proportions of modern human juveniles likely differ from those of small-bodied early hominins, human juveniles (like fossil hominins) often differ in size and proportions from adult human reference samples and, accordingly, serve as a useful model for assessing the robustness of morphometric prediction equations. Morphometric equations based on adults systematically underpredict body mass in the youngest age groups and moderately overpredict body mass in the older groups, which fall in the body size range of adult Australopithecus (∼26-46 kg). Differences in body proportions, notably the ratio of lower limb length to stature, influence predictive accuracy. Ontogenetic changes in these body proportions likely influence the shift in prediction error (from under- to overprediction). However, because morphometric equations are reasonably accurate when applied to this juvenile test sample, we argue these equations may be used to predict body mass in small-bodied hominins, despite the potential for some error induced by differing body proportions and/or extrapolation beyond the original reference sample range. Copyright © 2017 Elsevier Ltd. All rights reserved.
Phase Composition, Crystallite Size and Physical Properties of B2O3-added Forsterite Nano-ceramics
NASA Astrophysics Data System (ADS)
Pratapa, S.; Chairunnisa, A.; Nurbaiti, U.; Handoko, W. D.
2018-05-01
This study was aimed to know the effect of B2O3 addition on the phase composition, crystallite size and dielectric properties of forsterite (Mg2SiO4) nano-ceramics. It utilized a purified silica sand from Tanah Laut, South Kalimantan as the source of (amorphous) silica and a magnesium oxide (MgO) powder. They were thoroughly mixed and milled prior to calcination. The addition of 1, 2, 3, and 4 wt% B2O3 to the calcined powder was done before uniaxial pressing and then sintering at 950 °C for 4 h. The phase composition and forsterite crystallite size, the microstructure and the dielectric constant of the sintered samples were characterized using X-ray diffractometer (XRD), Scanning Electron Microscope (SEM) and Vector Network Analyzer (VNA), respectively. Results showed that all samples contained forsterite, periclase (MgO) and proto enstatite (MgSiO3) with different weight fractions and forsterite crystallite size. In general, the weight fraction and crystallite size of forsterite increased with increasing B2O3 addition. The weight fraction and crystallite size of forsterite in the 4%-added sample reached 99% wt and 164 nm. Furthermore, the SEM images showed that the average grain size became slightly larger and the ceramics also became slightly denser as more B2O3 was added. The results are in accordance with density measurements using the Archimedes method which showed that the 4% ceramic exhibited 1.845 g/cm3 apparent density, while the 1% ceramic 1.681 g/cm3. We also found that the higher the density, the higher the average dielectric constant, i.e. it was 4.6 for the 1%-added sample and 6.4 for the 4%-added sample.
Synthesis, characterization and electrocatalytic properties of delafossite CuGaO{sub 2}
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahmed, Jahangeer; Department of Chemistry, College of Science, King Saud University, Riyadh 11451; Mao, Yuanbing, E-mail: yuanbing.mao@utrgv.edu
2016-10-15
Delafossite CuGaO{sub 2} has been employed as photocatalysts for solar cells, but their electrocatalytic properties have not been extensively studied, especially no comparison among samples made by different synthesis routes. Herein, we first reported the successful synthesis of delafossite CuGaO{sub 2} particles with three different morphologies, i.e. nanocrystalline hexagons, sub-micron sized plates and micron–sized particles by a modified hydrothermal method at 190 °C for 60 h [1–3], a sono-chemical method followed by firing at 850 °C for 48 h, and a solid state route at 1150 °C, respectively. Morphology, composition and phase purity of the synthesized samples was confirmed bymore » powder X-ray diffraction and Raman spectroscopic studies, and then their electrocatalytic performance as active and cost effective electrode materials to the oxygen and hydrogen evolution reactions in 0.5 M KOH electrolyte versus Ag/AgCl was investigated and compared under the same conditions for the first time. The nanocrystalline CuGaO{sub 2} hexagons show enhanced electrocatalytic activity than the counterpart sub-micron sized plates and micron-sized particles. - Graphical abstract: Representative delafossite CuGaO2 samples with sub-micron sized plate and nanocrystalline hexagon morphologies accompanying with chronoamperometric voltammograms for oxygen evolution reaction and hydrogen evolution reaction in 0.5 M KOH electrolyte after purged with N{sub 2} gas. - Highlights: • Delafossite CuGaO{sub 2} with three morphologies has been synthesized. • Phase purity of the synthesized samples was confirmed. • Comparison on their electrocatalytic properties was made for the first time. • Their use as electrodes for oxygen and hydrogen evolution reactions was evaluated. • Nanocrystalline CuGaO{sub 2} hexagons show highest electrocatalytic activity.« less
Effect of microstructure on the thermoelectric performance of La{sub 1−x}Sr{sub x}CoO{sub 3}
DOE Office of Scientific and Technical Information (OSTI.GOV)
Viskadourakis, Z.; Department of Mechanical and Manufacturing Engineering, University of Cypruss, 75 Kallipoleos Avenue, P.O. Box 20537, 1678 Nicosia; Athanasopoulos, G.I.
We present a case where the microstructure has a profound effect on the thermoelectric properties of oxide compounds. Specifically, we have investigated the effect of different sintering treatments on La{sub 1−x}Sr{sub x}CoO{sub 3} samples synthesized using the Pechini method. We found that the samples, which are dense and consist of inhomogeneously-mixed grains of different size, exhibit both higher Seebeck coefficient and thermoelectric figure of merit than the samples, which are porous and consist of grains with almost identical size. The enhancement of Seebeck coefficient in the dense samples is attributed to the so-called “energy-filtering” mechanism that is related to themore » energy barrier of the grain boundary. On the other hand, the thermal conductivity for the porous compounds is significantly reduced in comparison to the dense compounds. It is suggested that a fine-manipulation of grain size ratio combined with a fine-tuning of porosity could considerably enhance the thermoelectric performance of oxides. - Graphical abstract: The enhancement of the dimensionless thermoelectric figure ZT of merit is presented for two equally Sr-doped LaCoO3 compounds, possessing different microstructure, indicating the effect of the latter to the thermoelectric performance of the La{sub 1−x}Sr{sub x}CoO{sub 3} solid solution. - Highlights: • Electrical and thermal transport properties are affected by the microstructure in La{sub 1−x}Sr{sub x}CoO{sub 3} polycrystalline materials. • Coarse/fine grain size distribution enhances the Seebeck coefficient. • Porosity reduces the thermal conductivity in La{sub 1−x}Sr{sub x}CoO{sub 3} polycrystalline samples. • The combination of large/small grain ratio distribution with the high porosity may result to the enhancement of the thermoelectric performance of the material.« less
Reduction Behavior of Assmang and Comilog ore in the SiMn Process
NASA Astrophysics Data System (ADS)
Kim, Pyunghwa Peace; Holtan, Joakim; Tangstad, Merete
The reduction behavior of raw materials from Assmang and Comilog based charges were experimentally investigated with CO gas up to 1600 °C. Quartz, HC FeMn slag or limestone were added to Assmang or Comilog according to the SiMn production charge, and mass loss results were obtained by using a TGA furnace. The results showed that particle size, type of manganese ore and mixture have close relationship to the reduction behavior of raw materials during MnO and SiO2 reduction. The influence of particle size to mass loss was apparent when Assmang or Comilog was mixed with only coke (FeMn) while it became insignificant when quartz and HC FeMn slag (SiMn) were added. This implied that quartz and HC FeMn slag had favored the incipient slag formation regardless of particle size. This explained the similar mass loss tendencies of SiMn charge samples between 1200-1500 °C, contrary to FeMn charge samples where different particle sizes showed significant difference in mass loss. Also, while FeMn charge samples showed progressive mass loss, SiMn charge samples showed diminutive mass loss until 1500 °C. However, rapid mass losses were observed with SiMn charge samples in this study above 1500 °C, and they have occurred at different temperatures. This implied rapid reduction of MnO and SiO2 and the type of ore and addition of HC FeMn slag have significant influence determining these temperatures. The temperatures observed for the rapid mass loss were approximately 1503 °C (Quartz and HC FeMn slag addition in Assmang), 1543 °C (Quartz addition in Assmang) and 1580-1587 °C (Quartz and limestone addition in Comilog), respectively. These temperatures also showed indications of possible SiMn production at process temperatures lower than 1550 °C.
Karyological features of wild and cultivated forms of myrtle (Myrtus communis, Myrtaceae).
Serçe, S; Ekbiç, E; Suda, J; Gündüz, K; Kiyga, Y
2010-03-09
Myrtle is an evergreen shrub or small tree widespread throughout the Mediterranean region. In Turkey, both cultivated and wild forms, differing in plant and fruit size and fruit composition, can be found. These differences may have resulted from the domestication of the cultivated form over a long period of time. We investigated whether wild and cultivated forms of myrtle differ in karyological features (i.e., number of somatic chromosomes and relative genome size). We sampled two wild forms and six cultivated types of myrtle. All the samples had the same chromosome number (2n = 2x = 22). The results were confirmed by 4',6-diamidino-2-phenylindole (DAPI) flow cytometry. Only negligible variation (approximately 3%) in relative fluorescence intensity was observed among the different myrtle accessions, with wild genotypes having the smallest values. We concluded that despite considerable morphological differentiation, cultivated and wild myrtle genotypes in Turkey have similar karyological features.
Magnetic fingerprint of the sediment load in a meander bend section of the Seine River (France)
NASA Astrophysics Data System (ADS)
Kayvantash, D.; Cojan, I.; Kissel, C.; Franke, C.
2017-06-01
This study aims to evaluate the potential of magnetic methods to determine the composition of the sediment load in a cross section of an unmanaged meander in the upstream stretch of the Seine River (Marnay-sur-Seine). Suspended particulate matter (SPM) was collected based on a regular sampling scheme along a cross section of the river, at two different depth levels: during a low-water stage (May 2014) and a high-water stage (February 2015). Riverbed sediments (RBS) were collected during the low-water stage and supplementary samples were taken from the outer and inner banks. Magnetic properties of the dry bulk SPM and sieved RBS and bank sediments were analysed. After characterizing the main magnetic carrier as magnetite, hysteresis parameters were measured, giving access to the grain size and the concentration of these magnetite particles. The results combined with sedimentary grain size data were compared to the three-dimensional velocity profile of the river flow. In the RBS where the magnetic grain size is rather uniform, the concentration of magnetite is inversely proportional to the mean grain size of the total sediment indicating that magnetite is strongly associated with the fine sedimentary fraction. The same pattern is observed in the samples from the outer and inner banks. During the low-water stage, the uniformly fine SPM grain size distribution characterizes the wash load. The magnetic fraction is also relatively fine (within the pseudo single domain range) with concentration similar to that of the fine RBS fraction. During the high-water stage, SPM samples correspond to mixtures of wash load and resuspended sediment from the bedload and riverbanks. Here, the grain size distribution is heterogeneous across the section showing coarser particles compared to those in the low-water stage and more varying magnetite concentrations while the magnetic grain size is like that of the low-water stage. The magnetite concentration in the high-water SPM can be modelled based on a mixing of the magnetite concentrations of the different grain size fractions, thus quantifying the impact of resuspension in the cross section.
Contado, Catia; Dalpiaz, Alessandro; Leo, Eliana; Zborowski, Maciej; Williams, P. Stephen
2009-01-01
Poly(lactic acid) nanoparticles were synthesized using a modified evaporation method, testing two different surfactants (sodium cholate and Pluronic F68) for the process. During their formulation the prodrug 5′-octanoyl-CPA (Oct-CPA) of the antiischemic N6-cyclopentyladenosine (CPA) was encapsulated. Three different purification methods were compared with respect to the influence of surfactant on the size characteristics of the final nanoparticle product. Flow and sedimentation field-flow fractionation techniques (FlFFF and SdFFF, respectively) were used to size characterize the five poly(lactic acid) particle samples. Two different combinations of carrier solution (mobile phase) were employed in the FlFFF analyses, while a solution of poly(vinyl alcohol) was used as mobile phase for the SdFFF runs. The separation performances of the two techniques were compared and the particle size distributions, derived from the fractograms, were interpreted with the support of observations by scanning electron microscopy. Some critical aspects, such as the carrier choice and the channel thickness determination for the FlFFF, have been investigated. This is the first comprehensive comparison of the two FFF techniques for characterizing non standard particulate materials. The two FFF techniques proved to be complementary and gave good, congruent and very useful information on the size distributions of the five poly(lactic acid) particle samples. PMID:17482199
Personal Exposure to Particulate Matter and Endotoxin in California Dairy Workers
NASA Astrophysics Data System (ADS)
Garcia, Johnny
The average number of cows per dairy has increased over the last thirty years, with little known about how this increase may impact occupational exposure. Thirteen California dairies and 226 workers participated in this study throughout the 2008 summer months. Particulate Matter (PM) and endotoxin concentrations were quantified using ambient area based and personal air samplers. Two size fractions were collected, Total Suspended Particulate matter (TSP) and PM 2.5. Differences across dairies were evaluated by placing area based integrated air samplers in established locations on the dairies, e.g. milking parlor, drylot corral, and freestall barns. The workers occupational exposure was quantified using personal air samplers. We analyzed concentrations along with the time workers spent conducting specific job tasks during their shift to identify high exposure job tasks. Biological and chemical analytical methods were employed to ascertain endotoxin concentrations in personal and area based air samples. Recombinant factor C assays (rFC) were used to analyze biologically active endotoxin and gas chromatography coupled with mass spectrometry in tandem (GC-MS/MS) was used to quantify total endotoxin. The PM2.5 concentrations ranged from 2-116 mug/m3 for ambient area concentration and 7-495 mug/m3 for personal concentrations while TSP concentrations ranged from 74-1690 mug/m3 for area ambient concentrations and 191-4950 mug/m3 for personal concentrations. Biologically active endotoxin concentrations in the TSP size fraction from ambient area based samples ranged from 11-2095 EU/m3 and 45-2061 EU/m3 for personal samples. Total endotoxin in the TSP size fraction ranged from 75-10,166 pmol/m3 for area based samples and 34-11,689 pmol/m3 for personal samples. Drylot corrals were found to have higher sample mean concentrations when compared to other locations on the dairies for PM and endotoxin. Re-bedding, of the freestalls, was found to consistently lead to higher personal sample mean concentrations when compared to other tasks performed on dairies for both endotoxin and PM. In mixed effect regression models, regional ambient concentrations of PM 2.5 helped account for variation in PM2.5 concentration outcomes. We found that while upwind and downwind mean concentrations were not significantly different, central mean concentrations were higher than upwind concentration. Variation in TSP levels was largely explained by dairy-level characteristics such as the age of the dairy and number of animals in the drylot corrals and freestall barns. The different locations within the dairy were found to differ in mean concentrations for TSP. Biologically active and total endotoxin concentration variation was explained by meteorological data, wind speed, relative humidity, and dairy waste management practices. Personal exposure levels where found to be higher than area based concentrations for PM and endotoxin. Endotoxin characteristics differed by particle size and location within the dairy. The chain length proportion for endotoxin in the PM 2.5 size fraction was dominated by C12 and C16 in the TSP size fraction.
Makan, Ashwell C; Spallek, Markus J; du Toit, Madeleine; Klein, Thorsten; Pasch, Harald
2016-04-15
Field flow fractionation (FFF) is an advanced fractionation technique for the analyses of very sensitive particles. In this study, different FFF techniques were used for the fractionation and analysis of polymer emulsions/latexes. As model systems, a pure acrylic emulsion and emulsions containing titanium dioxide were prepared and analyzed. An acrylic emulsion polymerization was conducted, continuously sampled from the reactor and subsequently analyzed to determine the particle size, radius of gyration in specific, of the latex particles throughout the polymerization reaction. Asymmetrical flow field-flow fractionation (AF4) and sedimentation field-flow fractionation (SdFFF), coupled to a multidetector system, multi-angle laser light scattering (MALLS), ultraviolet (UV) and refractive index (RI), respectively, were used to investigate the evolution of particle sizes and particle size distributions (PSDs) as the polymerization progressed. The obtained particle sizes were compared against batch-mode dynamic light scattering (DLS). Results indicated differences between AF4 and DLS results due to DLS taking hydration layers into account, whereas both AF4 and SdFFF were coupled to MALLS detection, hence not taking the hydration layer into account for size determination. SdFFF has additional separation capabilities with a much higher resolution compared to AF4. The calculated radii values were 5 nm larger for SdFFF measurements for each analyzed sample against the corresponding AF4 values. Additionally a low particle size shoulder was observed for SdFFF indicating bimodality in the reactor very early during the polymerization reaction. Furthermore, different emulsions were mixed with inorganic species used as additives in cosmetics and coatings such as TiO2. These complex mixtures of species were analyzed to investigate the retention and particle interaction behavior under different AF4 experimental conditions, such as the mobile phase. The AF4 system was coupled online to inductively coupled plasma mass spectrometry (ICP-MS) for elemental speciation and identification of the inorganic additive. SdFFF had a larger separation power to distinguish different particle size populations whereas AF4 had the capability of separating the organic particles and inorganic TiO2 particles, with high resolution. Copyright © 2016 Elsevier B.V. All rights reserved.
Pudda, Catherine; Boizot, François; Verplanck, Nicolas; Revol-Cavalier, Frédéric; Berthier, Jean; Thuaire, Aurélie
2018-01-01
Particle separation in microfluidic devices is a common problematic for sample preparation in biology. Deterministic lateral displacement (DLD) is efficiently implemented as a size-based fractionation technique to separate two populations of particles around a specific size. However, real biological samples contain components of many different sizes and a single DLD separation step is not sufficient to purify these complex samples. When connecting several DLD modules in series, pressure balancing at the DLD outlets of each step becomes critical to ensure an optimal separation efficiency. A generic microfluidic platform is presented in this paper to optimize pressure balancing, when DLD separation is connected either to another DLD module or to a different microfluidic function. This is made possible by generating droplets at T-junctions connected to the DLD outlets. Droplets act as pressure controllers, which perform at the same time the encapsulation of DLD sorted particles and the balance of output pressures. The optimized pressures to apply on DLD modules and on T-junctions are determined by a general model that ensures the equilibrium of the entire platform. The proposed separation platform is completely modular and reconfigurable since the same predictive model applies to any cascaded DLD modules of the droplet-based cartridge. PMID:29768490
NASA Astrophysics Data System (ADS)
Sk, Md. Basiruddin; Ghosh, A.; Rarhi, N.; Balamuralikrishnan, R.; Chakrabarti, D.
2017-07-01
In order to achieve the desired mechanical properties [YS > 390 MPa, total elongation >16 pct and Charpy impact toughness of 78 J at 213 K (-60 °C)] for naval application, samples from a low-carbon microalloyed steel have been subjected to different austenitization (1223 K to 1523 K) (950 °C to 1250 °C) and cooling treatments (furnace, air, or water cooling). The as-rolled steel and the sample air cooled from 1223 K (950 °C) could only achieve the required tensile properties, while the sample furnace cooled from 1223 K (950 °C) showed the best Charpy impact properties. Water quenching from 1223 K (950 °C) certainly contributed to the strength but affected the impact toughness. Overall, predominantly ferrite matrix with fine effective grain size and intense gamma-fiber texture was found to be beneficial for impact toughness as well as impact transition behavior. Small size and fraction of precipitates (like TiN, Nb, and V carbonitrides) eliminated the possibility of particle-controlled crack propagation and grain size-controlled crack propagation led to cleavage fracture. A simplified analytical approach has been used to explain the difference in impact transition behavior of the investigated samples.
Effect of high pressure processing on dispersive and aggregative properties of almond milk.
Dhakal, Santosh; Giusti, M Monica; Balasubramaniam, V M
2016-08-01
A study was conducted to investigate the impact of high pressure (450 and 600 MPa at 30 °C) and thermal (72, 85 and 99 °C at 0.1 MPa) treatments on dispersive and aggregative characteristics of almond milk. Experiments were conducted using a kinetic pressure testing unit and water bath. Particle size distribution, microstructure, UV absorption spectra, pH and color changes of processed and unprocessed samples were analyzed. Raw almond milk represented the mono model particle size distribution with average particle diameters of 2 to 3 µm. Thermal or pressure treatment of almond milk shifted the particle size distribution towards right and increased particle size by five- to six-fold. Micrographs confirmed that both the treatments increased particle size due to aggregation of macromolecules. Pressure treatment produced relatively more and larger aggregates than those produced by heat treated samples. The apparent aggregation rate constant for 450 MPa and 600 MPa processed samples were k450MPa,30°C = 0.0058 s(-1) and k600MPa,30°C = 0.0095 s(-1) respectively. This study showed that dispersive and aggregative properties of high pressure and heat-treated almond milk were different due to differences in protein denaturation, particles coagulation and aggregates morphological characteristics. Knowledge gained from the study will help food processors to formulate novel plant-based beverages treated with high pressure. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.
NASA Astrophysics Data System (ADS)
Reitz, M. A.; Seeber, L.; Schaefer, J. M.; Ferguson, E. K.
2012-12-01
Early studies pioneering the method for catchment wide erosion rates by measuring 10Be in alluvial sediment were taken at river mouths and used the sand size grain fraction from the riverbeds in order to average upstream erosion rates and measure erosion patterns. Finer particles (<0.0625 mm) were excluded to reduce the possibility of a wind-blown component of sediment and coarser particles (>2 mm) were excluded to better approximate erosion from the entire upstream catchment area (coarse grains are generally found near the source). Now that the sensitivity of 10Be measurements is rapidly increasing, we can precisely measure erosion rates from rivers eroding active tectonic regions. These active regions create higher energy drainage systems that erode faster and carry coarser sediment. In these settings, does the sand-sized fraction fully capture the average erosion of the upstream drainage area? Or does a different grain size fraction provide a more accurate measure of upstream erosion? During a study of the Neto River in Calabria, southern Italy, we took 8 samples along the length of the river, focusing on collecting samples just below confluences with major tributaries, in order to use the high-resolution erosion rate data to constrain tectonic motion. The samples we measured were sieved to either a 0.125 mm - 0.710 mm fraction or the 0.125 mm - 4 mm fraction (depending on how much of the former was available). After measuring these 8 samples for 10Be and determining erosion rates, we used the approach by Granger et al. [1996] to calculate the subcatchment erosion rates between each sample point. In the subcatchments of the river where we used grain sizes up to 4 mm, we measured very low 10Be concentrations (corresponding to high erosion rates) and calculated nonsensical subcatchment erosion rates (i.e. negative rates). We, therefore, hypothesize that the coarser grain sizes we included are preferentially sampling a smaller upstream area, and not the entire upstream catchment, which is assumed when measurements are based solely on the sand sized fraction. To test this hypothesis, we used samples with a variety of grain sizes from the Shillong Plateau. We sieved 5 samples into three grain size fractions: 0.125 mm - 710 mm, 710 mm - 4 mm, and >4 mm and measured 10Be concentrations in each fraction. Although there is some variation in the grain size fraction that yields the highest erosion rate, generally, the coarser grain size fractions have higher erosion rates. More significant are the results when calculating the subcatchment erosion rates, which suggest that even medium sized grains (710 mm - 4 mm) are sampling an area smaller than the entire upstream area; this finding is consistent with the nonsensical results from the Neto River study. This result has numerous implications for the interpretations of 10Be erosion rates: most importantly, an alluvial sample may not be averaging the entire upstream area, even when using the sand size fraction - resulting erosion rates more pertinent for that sample point rather than the entire catchment.
NASA Astrophysics Data System (ADS)
Liu, Cenwei; Lobb, David; Li, Sheng; Owens, Philip; Kuzyk, ZouZou
2014-05-01
Lake Winnipeg has recently brought attention to the deteriorated water quality due to in part to nutrient and sediment input from agricultural land. Improving water quality in Lake Winnipeg requires the knowledge of the sediment sources within this ecosystem. There are a variety of environmental fingerprinting techniques have been successfully used in the assessment of sediment sources. In this study, we used particle size distribution to evaluate spatial and temporal variations of suspended sediment and potential sediment sources collected in the Tobacco Creek Watershed in Manitoba, Canada. The particle size distribution of suspended sediment can reflect the origin of sediment and processes during sediment transport, deposition and remobilization within the watershed. The objectives of this study were to quantify visually observed spatial and temporal changes in sediment particles, and to assess the sediment source using a rapid and cost-effective fingerprinting technique based on particle size distribution. The suspended sediment was collected by sediment traps twice a year during rainfall and snowmelt periods from 2009 to 2012. The potential sediment sources included the top soil of cultivated field, riparian area and entire profile from stream banks. Suspended sediment and soil samples were pre-wet with RO water and sieved through 600 μm sieve before analyzing. Particle size distribution of all samples was determined using a Malvern Mastersizer 2000S laser diffraction with the measurement range up to 600μm. Comparison of the results for different fractions of sediment showed significant difference in particle size distribution of suspended sediment between snowmelt and rainfall events. An important difference of particle size distribution also found between the cultivated soil and forest soil. This difference can be explained by different land uses which provided a distinct fingerprint of sediment. An overall improvement in water quality can be achieved by managing sediment according to the identified sediment sources in the watershed.
Synthesis, characterization and electrocatalytic properties of delafossite CuGaO2
NASA Astrophysics Data System (ADS)
Ahmed, Jahangeer; Mao, Yuanbing
2016-10-01
Delafossite CuGaO2 has been employed as photocatalysts for solar cells, but their electrocatalytic properties have not been extensively studied, especially no comparison among samples made by different synthesis routes. Herein, we first reported the successful synthesis of delafossite CuGaO2 particles with three different morphologies, i.e. nanocrystalline hexagons, sub-micron sized plates and micron-sized particles by a modified hydrothermal method at 190 °C for 60 h [1-3], a sono-chemical method followed by firing at 850 °C for 48 h, and a solid state route at 1150 °C, respectively. Morphology, composition and phase purity of the synthesized samples was confirmed by powder X-ray diffraction and Raman spectroscopic studies, and then their electrocatalytic performance as active and cost effective electrode materials to the oxygen and hydrogen evolution reactions in 0.5 M KOH electrolyte versus Ag/AgCl was investigated and compared under the same conditions for the first time. The nanocrystalline CuGaO2 hexagons show enhanced electrocatalytic activity than the counterpart sub-micron sized plates and micron-sized particles.
Automatic classification techniques for type of sediment map from multibeam sonar data
NASA Astrophysics Data System (ADS)
Zakariya, R.; Abdullah, M. A.; Che Hasan, R.; Khalil, I.
2018-02-01
Sediment map can be important information for various applications such as oil drilling, environmental and pollution study. A study on sediment mapping was conducted at a natural reef (rock) in Pulau Payar using Sound Navigation and Ranging (SONAR) technology which is Multibeam Echosounder R2-Sonic. This study aims to determine sediment type by obtaining backscatter and bathymetry data from multibeam echosounder. Ground truth data were used to verify the classification produced. The method used to analyze ground truth samples consists of particle size analysis (PSA) and dry sieving methods. Different analysis being carried out due to different sizes of sediment sample obtained. The smaller size was analyzed using PSA with the brand CILAS while bigger size sediment was analyzed using sieve. For multibeam, data acquisition includes backscatter strength and bathymetry data were processed using QINSy, Qimera, and ArcGIS. This study shows the capability of multibeam data to differentiate the four types of sediments which are i) very coarse sand, ii) coarse sand, iii) very coarse silt and coarse silt. The accuracy was reported as 92.31% overall accuracy and 0.88 kappa coefficient.
Conn, Vicki S; Ruppar, Todd M; Chase, Jo-Ana D; Enriquez, Maithe; Cooper, Pamela S
2015-12-01
This systematic review applied meta-analytic procedures to synthesize medication adherence interventions that focus on adults with hypertension. Comprehensive searching located trials with medication adherence behavior outcomes. Study sample, design, intervention characteristics, and outcomes were coded. Random-effects models were used in calculating standardized mean difference effect sizes. Moderator analyses were conducted using meta-analytic analogues of ANOVA and regression to explore associations between effect sizes and sample, design, and intervention characteristics. Effect sizes were calculated for 112 eligible treatment-vs.-control group outcome comparisons of 34,272 subjects. The overall standardized mean difference effect size between treatment and control subjects was 0.300. Exploratory moderator analyses revealed interventions were most effective among female, older, and moderate- or high-income participants. The most promising intervention components were those linking adherence behavior with habits, giving adherence feedback to patients, self-monitoring of blood pressure, using pill boxes and other special packaging, and motivational interviewing. The most effective interventions employed multiple components and were delivered over many days. Future research should strive for minimizing risks of bias common in this literature, especially avoiding self-report adherence measures.
NASA Astrophysics Data System (ADS)
Traforti, Anna; Mari, Giovanna; Carli, Cristian; Demurtas, Matteo; Massironi, Matteo; Di Toro, Giulio
2017-04-01
Reflectance spectroscopy in the visible and near-infrared (VNIR) is a common technique used to study the mineral composition of Solar System bodies from remote sensed and in-situ robotic exploration. In the VNIR spectral range, both crystal field and vibrational overtone absorptions can be present with spectral characteristics (i.e. albedo, slopes, absorption band with different positions and depths) that vary depending on composition and texture (e.g. grain size, roughness) of the sensed materials. The characterization of the spectral variability related to the rock texture, especially in terms of grain size (i.e., both the size of rock components and the size of particulates), commonly allows to obtain a wide range of information about the different geological processes modifying the planetary surfaces. This work is aimed at characterizing how the grain size reduction associated to fault zone development produces reflectance variations in rock and mineral spectral signatures. To achieve this goal we present VNIR reflectance analysis of a set of fifteen rock samples collected at increasing distances from the fault core of the Vado di Corno fault zone (Campo Imperatore Fault System - Italian Central Apennines). The selected samples had similar content of calcite and dolomite but different grain size (X-Ray Powder Diffraction, optical and scanning electron microscopes analysis). Consequently, differences in the spectral signature of the fault rocks should not be ascribed to mineralogical composition. For each sample, bidirectional reflectance spectra were acquired with a Field-Pro Spectrometer mounted on a goniometer, on crushed rock slabs reduced to grain size <800, <200, <63, <10 μm and on intact fault zone rock slabs. The spectra were acquired on dry samples, at room temperature and normal atmospheric pressure. The source used was a Tungsten Halogen lamp with an illuminated spot area of ca. 0.5 cm2and incidence and emission angles of 30˚ and 0˚ respectively. The spectral analysis of the crushed and intact rock slabs in the VNIR spectral range revealed that in both cases, with increasing grain size: (i) the reflectance decreases (ii) VNIR spectrum slopes (i.e. calculated between wavelengths of 0.425 - 0.605 μm and 2.205 - 2.33 μm, respectively) and (iii) carbonate main absorption band depth (i.e. vibrational absorption band at wavelength of ˜2.3 μm) increase. In conclusion, grain size variations resulting from the fault zone evolution (e.g., cumulated slip or development of thick damage zones) produce reflectance variations in rocks and mineral spectral signatures. The remote sensing analysis in the VNIR spectral range can be applied to identify the spatial distribution and extent of fault core and damage zone domains for industrial and seismic hazard applications. Moreover, the spectral characterization of carbonate-built rocks can be of great interest for the surface investigation of inner planets (e.g. Earth and Mars) and outer bodies (e.g. Galilean icy satellites). On these surfaces, carbonate minerals at different grain sizes are common and usually related to water and carbon distribution, with direct implications for potential life outside Earth (e.g. Mars).
Landsat image and sample design for water reservoirs (Rapel dam Central Chile).
Lavanderos, L; Pozo, M E; Pattillo, C; Miranda, H
1990-01-01
Spatial heterogeneity of the Rapel reservoir surface waters is analyzed through Landsat images. The image digital counts are used with the aim or developing an aprioristic quantitative sample design.Natural horizontal stratification of the Rapel Reservoir (Central Chile) is produced mainly by suspended solids. The spatial heterogeneity conditions of the reservoir for the Spring 86-Summer 87 period were determined by qualitative analysis and image processing of the MSS Landsat, bands 1 and 3. The space-time variations of the different observed strata obtained with multitemporal image analysis.A random stratified sample design (r.s.s.d) was developed, based on the digital counts statistical analysis. Strata population size as well as the average, variance and sampling size of the digital counts were obtained by the r.s.s.d method.Stratification determined by analysis of satellite images were later correlated with ground data. Though the stratification of the reservoir is constant over time, the shape and size of the strata varys.
ZnFe2O4 nanoparticles dispersed in a highly porous silica aerogel matrix: a magnetic study.
Bullita, S; Casu, A; Casula, M F; Concas, G; Congiu, F; Corrias, A; Falqui, A; Loche, D; Marras, C
2014-03-14
We report the detailed structural characterization and magnetic investigation of nanocrystalline zinc ferrite nanoparticles supported on a silica aerogel porous matrix which differ in size (in the range 4-11 nm) and the inversion degree (from 0.4 to 0.2) as compared to bulk zinc ferrite which has a normal spinel structure. The samples were investigated by zero-field-cooling-field-cooling, thermo-remnant DC magnetization measurements, AC magnetization investigation and Mössbauer spectroscopy. The nanocomposites are superparamagnetic at room temperature; the temperature of the superparamagnetic transition in the samples decreases with the particle size and therefore it is mainly determined by the inversion degree rather than by the particle size, which would give an opposite effect on the blocking temperature. The contribution of particle interaction to the magnetic behavior of the nanocomposites decreases significantly in the sample with the largest particle size. The values of the anisotropy constant give evidence that the anisotropy constant decreases upon increasing the particle size of the samples. All these results clearly indicate that, even when dispersed with low concentration in a non-magnetic and highly porous and insulating matrix, the zinc ferrite nanoparticles show a magnetic behavior similar to that displayed when they are unsupported or dispersed in a similar but denser matrix, and with higher loading. The effective anisotropy measured for our samples appears to be systematically higher than that measured for supported zinc ferrite nanoparticles of similar size, indicating that this effect probably occurs as a consequence of the high inversion degree.
Quantifying the size-resolved dynamics of indoor bioaerosol transport and control.
Kunkel, S A; Azimi, P; Zhao, H; Stark, B C; Stephens, B
2017-09-01
Understanding the bioaerosol dynamics of droplets and droplet nuclei emitted during respiratory activities is important for understanding how infectious diseases are transmitted and potentially controlled. To this end, we conducted experiments to quantify the size-resolved dynamics of indoor bioaerosol transport and control in an unoccupied apartment unit operating under four different HVAC particle filtration conditions. Two model organisms (Escherichia coli K12 and bacteriophage T4) were aerosolized under alternating low and high flow rates to roughly represent constant breathing and periodic coughing. Size-resolved aerosol sampling and settle plate swabbing were conducted in multiple locations. Samples were analyzed by DNA extraction and quantitative polymerase chain reaction (qPCR). DNA from both organisms was detected during all test conditions in all air samples up to 7 m away from the source, but decreased in magnitude with the distance from the source. A greater fraction of T4 DNA was recovered from the aerosol size fractions smaller than 1 μm than E. coli K12 at all air sampling locations. Higher efficiency HVAC filtration also reduced the amount of DNA recovered in air samples and on settle plates located 3-7 m from the source. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Dawson, Ree; Lavori, Philip W
2012-01-01
Clinical demand for individualized "adaptive" treatment policies in diverse fields has spawned development of clinical trial methodology for their experimental evaluation via multistage designs, building upon methods intended for the analysis of naturalistically observed strategies. Because often there is no need to parametrically smooth multistage trial data (in contrast to observational data for adaptive strategies), it is possible to establish direct connections among different methodological approaches. We show by algebraic proof that the maximum likelihood (ML) and optimal semiparametric (SP) estimators of the population mean of the outcome of a treatment policy and its standard error are equal under certain experimental conditions. This result is used to develop a unified and efficient approach to design and inference for multistage trials of policies that adapt treatment according to discrete responses. We derive a sample size formula expressed in terms of a parametric version of the optimal SP population variance. Nonparametric (sample-based) ML estimation performed well in simulation studies, in terms of achieved power, for scenarios most likely to occur in real studies, even though sample sizes were based on the parametric formula. ML outperformed the SP estimator; differences in achieved power predominately reflected differences in their estimates of the population mean (rather than estimated standard errors). Neither methodology could mitigate the potential for overestimated sample sizes when strong nonlinearity was purposely simulated for certain discrete outcomes; however, such departures from linearity may not be an issue for many clinical contexts that make evaluation of competitive treatment policies meaningful.
Development of a multichannel hyperspectral imaging probe for food property and quality assessment
NASA Astrophysics Data System (ADS)
Huang, Yuping; Lu, Renfu; Chen, Kunjie
2017-05-01
This paper reports on the development, calibration and evaluation of a new multipurpose, multichannel hyperspectral imaging probe for property and quality assessment of food products. The new multichannel probe consists of a 910 μm fiber as a point light source and 30 light receiving fibers of three sizes (i.e., 50 μm, 105 μm and 200 μm) arranged in a special pattern to enhance signal acquisitions over the spatial distances of up to 36 mm. The multichannel probe allows simultaneous acquisition of 30 spatially-resolved reflectance spectra of food samples with either flat or curved surface over the spectral region of 550-1,650 nm. The measured reflectance spectra can be used for estimating the optical scattering and absorption properties of food samples, as well as for assessing the tissues of the samples at different depths. Several calibration procedures that are unique to this probe were carried out; they included linearity calibrations for each channel of the hyperspectral imaging system to ensure consistent linear responses of individual channels, and spectral response calibrations of individual channels for each fiber size group and between the three groups of different size fibers. Finally, applications of this new multichannel probe were demonstrated through the optical property measurement of liquid model samples and tomatoes of different maturity levels. The multichannel probe offers new capabilities for optical property measurement and quality detection of food and agricultural products.
Kühberger, Anton; Fritz, Astrid; Scherndl, Thomas
2014-01-01
Background The p value obtained from a significance test provides no information about the magnitude or importance of the underlying phenomenon. Therefore, additional reporting of effect size is often recommended. Effect sizes are theoretically independent from sample size. Yet this may not hold true empirically: non-independence could indicate publication bias. Methods We investigate whether effect size is independent from sample size in psychological research. We randomly sampled 1,000 psychological articles from all areas of psychological research. We extracted p values, effect sizes, and sample sizes of all empirical papers, and calculated the correlation between effect size and sample size, and investigated the distribution of p values. Results We found a negative correlation of r = −.45 [95% CI: −.53; −.35] between effect size and sample size. In addition, we found an inordinately high number of p values just passing the boundary of significance. Additional data showed that neither implicit nor explicit power analysis could account for this pattern of findings. Conclusion The negative correlation between effect size and samples size, and the biased distribution of p values indicate pervasive publication bias in the entire field of psychology. PMID:25192357
Kühberger, Anton; Fritz, Astrid; Scherndl, Thomas
2014-01-01
The p value obtained from a significance test provides no information about the magnitude or importance of the underlying phenomenon. Therefore, additional reporting of effect size is often recommended. Effect sizes are theoretically independent from sample size. Yet this may not hold true empirically: non-independence could indicate publication bias. We investigate whether effect size is independent from sample size in psychological research. We randomly sampled 1,000 psychological articles from all areas of psychological research. We extracted p values, effect sizes, and sample sizes of all empirical papers, and calculated the correlation between effect size and sample size, and investigated the distribution of p values. We found a negative correlation of r = -.45 [95% CI: -.53; -.35] between effect size and sample size. In addition, we found an inordinately high number of p values just passing the boundary of significance. Additional data showed that neither implicit nor explicit power analysis could account for this pattern of findings. The negative correlation between effect size and samples size, and the biased distribution of p values indicate pervasive publication bias in the entire field of psychology.
Sehmel, George A.
1979-01-01
An isokinetic air sampler includes a filter, a holder for the filter, an air pump for drawing air through the filter at a fixed, predetermined rate, an inlet assembly for the sampler having an inlet opening therein of a size such that isokinetic air sampling is obtained at a particular wind speed, a closure for the inlet opening and means for simultaneously opening the closure and turning on the air pump when the wind speed is such that isokinetic air sampling is obtained. A system incorporating a plurality of such samplers provided with air pumps set to draw air through the filter at the same fixed, predetermined rate and having different inlet opening sizes for use at different wind speeds is included within the ambit of the present invention as is a method of sampling air to measure airborne concentrations of particulate pollutants as a function of wind speed.
Log-Normal Distribution of Cosmic Voids in Simulations and Mocks
NASA Astrophysics Data System (ADS)
Russell, E.; Pycke, J.-R.
2017-01-01
Following up on previous studies, we complete here a full analysis of the void size distributions of the Cosmic Void Catalog based on three different simulation and mock catalogs: dark matter (DM), haloes, and galaxies. Based on this analysis, we attempt to answer two questions: Is a three-parameter log-normal distribution a good candidate to satisfy the void size distributions obtained from different types of environments? Is there a direct relation between the shape parameters of the void size distribution and the environmental effects? In an attempt to answer these questions, we find here that all void size distributions of these data samples satisfy the three-parameter log-normal distribution whether the environment is dominated by DM, haloes, or galaxies. In addition, the shape parameters of the three-parameter log-normal void size distribution seem highly affected by environment, particularly existing substructures. Therefore, we show two quantitative relations given by linear equations between the skewness and the maximum tree depth, and between the variance of the void size distribution and the maximum tree depth, directly from the simulated data. In addition to this, we find that the percentage of voids with nonzero central density in the data sets has a critical importance. If the number of voids with nonzero central density reaches ≥3.84% in a simulation/mock sample, then a second population is observed in the void size distributions. This second population emerges as a second peak in the log-normal void size distribution at larger radius.
Urey, Carlos; Weiss, Victor U; Gondikas, Andreas; von der Kammer, Frank; Hofmann, Thilo; Marchetti-Deschmann, Martina; Allmaier, Günter; Marko-Varga, György; Andersson, Roland
2016-11-20
For drug delivery, characterization of liposomes regarding size, particle number concentrations, occurrence of low-sized liposome artefacts and drug encapsulation are of importance to understand their pharmacodynamic properties. In our study, we aimed to demonstrate the applicability of nano Electrospray Gas-Phase Electrophoretic Mobility Molecular Analyser (nES GEMMA) as a suitable technique for analyzing these parameters. We measured number-based particle concentrations, identified differences in size between nominally identical liposomal samples, and detected the presence of low-diameter material which yielded bimodal particle size distributions. Subsequently, we compared these findings to dynamic light scattering (DLS) data and results from light scattering experiments coupled to Asymmetric Flow-Field Flow Fractionation (AF4), the latter improving the detectability of smaller particles in polydisperse samples due to a size separation step prior detection. However, the bimodal size distribution could not be detected due to method inherent limitations. In contrast, cryo transmission electron microscopy corroborated nES GEMMA results. Hence, gas-phase electrophoresis proved to be a versatile tool for liposome characterization as it could analyze both vesicle size and size distribution. Finally, a correlation of nES GEMMA results with cell viability experiments was carried out to demonstrate the importance of liposome batch-to-batch control as low-sized sample components possibly impact cell viability. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Szabo, Z.; Oden, J.H.; Gibs, J.; Rice, D.E.; Ding, Y.; ,
2001-01-01
Particulates that move with ground water and those that are artificially mobilized during well purging could be incorporated into water samples during collection and could cause trace-element concentrations to vary in unfiltered samples, and possibly in filtered samples (typically 0.45-um (micron) pore size) as well, depending on the particle-size fractions present. Therefore, measured concentrations may not be representative of those in the aquifer. Ground water may contain particles of various sizes and shapes that are broadly classified as colloids, which do not settle from water, and particulates, which do. In order to investigate variations in trace-element concentrations in ground-water samples as a function of particle concentrations and particle-size fractions, the U.S. Geological Survey, in cooperation with the U.S. Air Force, collected samples from five wells completed in the unconfined, oxic Kirkwood-Cohansey aquifer system of the New Jersey Coastal Plain. Samples were collected by purging with a portable pump at low flow (0.2-0.5 liters per minute and minimal drawdown, ideally less than 0.5 foot). Unfiltered samples were collected in the following sequence: (1) within the first few minutes of pumping, (2) after initial turbidity declined and about one to two casing volumes of water had been purged, and (3) after turbidity values had stabilized at less than 1 to 5 Nephelometric Turbidity Units. Filtered samples were split concurrently through (1) a 0.45-um pore size capsule filter, (2) a 0.45-um pore size capsule filter and a 0.0029-um pore size tangential-flow filter in sequence, and (3), in selected cases, a 0.45-um and a 0.05-um pore size capsule filter in sequence. Filtered samples were collected concurrently with the unfiltered sample that was collected when turbidity values stabilized. Quality-assurance samples consisted of sequential duplicates (about 25 percent) and equipment blanks. Concentrations of particles were determined by light scattering. Variations in concentrations aluminum and iron (1 -74 and 1-199 ug/L (micrograms per liter), respectively), common indicators of the presence of particulate-borne trace elements, were greatest in sample sets from individual wells with the greatest variations in turbidity and particle concentration. Differences in trace-element concentrations in sequentially collected unfiltered samples with variable turbidity were 5 to 10 times as great as those in concurrently collected samples that were passed through various filters. These results indicate that turbidity must be both reduced and stabilized even when low-flow sample-collection techniques are used in order to obtain water samples that do not contain considerable particulate artifacts. Currently (2001) available techniques need to be refined to ensure that the measured trace-element concentrations are representative of those that are mobile in the aquifer water.
Willan, Andrew R
2016-07-05
The Pessary for the Prevention of Preterm Birth Study (PS3) is an international, multicenter, randomized clinical trial designed to examine the effectiveness of the Arabin pessary in preventing preterm birth in pregnant women with a short cervix. During the design of the study two methodological issues regarding power and sample size were raised. Since treatment in the Standard Arm will vary between centers, it is anticipated that so too will the probability of preterm birth in that arm. This will likely result in a treatment by center interaction, and the issue of how this will affect the sample size requirements was raised. The sample size requirements to examine the effect of the pessary on the baby's clinical outcome was prohibitively high, so the second issue is how best to examine the effect on clinical outcome. The approaches taken to address these issues are presented. Simulation and sensitivity analysis were used to address the sample size issue. The probability of preterm birth in the Standard Arm was assumed to vary between centers following a Beta distribution with a mean of 0.3 and a coefficient of variation of 0.3. To address the second issue a Bayesian decision model is proposed that combines the information regarding the between-treatment difference in the probability of preterm birth from PS3 with the data from the Multiple Courses of Antenatal Corticosteroids for Preterm Birth Study that relate preterm birth and perinatal mortality/morbidity. The approach provides a between-treatment comparison with respect to the probability of a bad clinical outcome. The performance of the approach was assessed using simulation and sensitivity analysis. Accounting for a possible treatment by center interaction increased the sample size from 540 to 700 patients per arm for the base case. The sample size requirements increase with the coefficient of variation and decrease with the number of centers. Under the same assumptions used for determining the sample size requirements, the simulated mean probability that pessary reduces the risk of perinatal mortality/morbidity is 0.98. The simulated mean decreased with coefficient of variation and increased with the number of clinical sites. Employing simulation and sensitivity analysis is a useful approach for determining sample size requirements while accounting for the additional uncertainty due to a treatment by center interaction. Using a surrogate outcome in conjunction with a Bayesian decision model is an efficient way to compare important clinical outcomes in a randomized clinical trial in situations where the direct approach requires a prohibitively high sample size.
DOT National Transportation Integrated Search
1976-09-01
Standardized injury rates and seat belt effectiveness measures are derived from a probability sample of towaway accidents involving 1973-1975 model cars. The data were collected in five different geographic regions. Weighted sample size available for...
Guo, Jiin-Huarng; Luh, Wei-Ming
2009-05-01
When planning a study, sample size determination is one of the most important tasks facing the researcher. The size will depend on the purpose of the study, the cost limitations, and the nature of the data. By specifying the standard deviation ratio and/or the sample size ratio, the present study considers the problem of heterogeneous variances and non-normality for Yuen's two-group test and develops sample size formulas to minimize the total cost or maximize the power of the test. For a given power, the sample size allocation ratio can be manipulated so that the proposed formulas can minimize the total cost, the total sample size, or the sum of total sample size and total cost. On the other hand, for a given total cost, the optimum sample size allocation ratio can maximize the statistical power of the test. After the sample size is determined, the present simulation applies Yuen's test to the sample generated, and then the procedure is validated in terms of Type I errors and power. Simulation results show that the proposed formulas can control Type I errors and achieve the desired power under the various conditions specified. Finally, the implications for determining sample sizes in experimental studies and future research are discussed.
Particulate sizing and emission indices for a jet engine exhaust sampled at cruise
NASA Astrophysics Data System (ADS)
Hagen, D.; Whitefield, P.; Paladino, J.; Trueblood, M.; Lilenfeld, H.
Particle size and emission indices measurements for jet engines, primarily the Rolls Royce RB211 engines on a NASA 757 aircraft are reported. These data were used to estimate the fraction of fuel sulfur that was converted to particulates. These measurements were made in-situ with the sampling aircraft several kilometers behind the source. Some complimentary ground measurements on the same source aircraft and engines are also reported. Significant differences are seen between the ground observations and the in-situ observations, indicating that plume processes are changing the aerosol's characteristics.
NASA Astrophysics Data System (ADS)
Marty, Adam J.
The purpose of this research is to demonstrate the ability to generate and characterize a nanometer sized aerosol using solutions, suspensions, and a bulk nanopowder, and to research the viability of using an acoustic dry aerosol generator/elutriator (ADAGE) to aerosolize a bulk nanopowder into a nanometer sized aerosol. The research compares the results from a portable scanning mobility particle sizer (SMPS) to the more traditional method of counting and sizing particles on a filter sample using scanning electron microscopy (SEM). Sodium chloride aerosol was used for the comparisons. The sputter coating thickness, a conductive coating necessary for SEM, was measured on different sizes of polystyrene latex spheres (PSLS). Aluminum oxide powder was aerosolized using an ADAGE and several different support membranes and sound frequency combinations were explored. A portable SMPS was used to determine the size distributions of the generated aerosols. Polycarbonate membrane (PCM) filter samples were collected for subsequent SEM analysis. The particle size distributions were determined from photographs of the membrane filters. SMPS data and membrane samples were collected simultaneously. The sputter coating thicknesses on four different sizes of PSLS, range 57 nanometers (nm) to 220 nm, were measured using transmission electron microscopy and the results from the SEM and SMPS were compared after accounting for the sputter coating thickness. Aluminum oxide nanopowder (20 nm) was aerosolized using a modified ADAGE technique. Four different support membranes and four different sound frequencies were tested with the ADAGE. The aerosol was collected onto PCM filters and the samples were examined using SEM. The results indicate that the SMPS and SEM distributions were log-normally distributed with a median diameter of approximately 42 nm and 55 nm, respectively, and geometric standard deviations (GSD) of approximately 1.6 and 1.7, respectively. The two methods yielded similar distributional trends with a difference in median diameters of approximately 11 -- 15 nm. The sputter coating thickness on the different sizes of PSLSs ranged from 15.4 -- 17.4 nm. The aerosols generated, using the modified ADAGE, were low in concentration. The particles remained as agglomerates and varied widely in size. An aluminum foil support membrane coupled with a high sound frequency generated the smallest agglomerates. A well characterized sodium chloride aerosol was generated and was reproducible. The distributions determined using SEM were slightly larger than those obtained from SMPS, however, the distributions had relatively the same shape as reflected in their GSDs. This suggests that a portable SMPS is a suitable method for characterizing a nanoaerosol. The sizing techniques could be compared after correcting for the effects of the sputter coating necessary for SEM examination. It was determined that the sputter coating thickness on nano-sized particles and particles up to approximately 220 nm can be expected to be the same and that the sputter coating can add considerably to the size of a nanoparticle. This has important implications for worker health where nanoaerosol exposure is a concern. The sputter coating must be considered when SEM is used to describe a nanoaerosol exposure. The performance of the modified ADAGE was less than expected. The low aerosol output from the ADAGE prevented a more detailed analysis and was limited to only a qualitative comparison. Some combinations of support membranes and sound frequencies performed better than others, particularly conductive support membranes and high sound frequencies. In conclusion, a portable SMPS yielded results similar to those obtained by SEM. The sputter coating was the same thickness on the PSLSs studied. The sputter coating thickness must be considered when characterizing nanoparticles using SEM. Finally, a conductive support membrane and higher frequencies appeared to generate the smallest agglomerates using the ADAGE technique.
Cetinić, Ivona; Poulton, Nicole; Slade, Wayne H
2016-09-05
Many optical and biogeochemical data sets, crucial for algorithm development and satellite data validation, are collected using underway seawater systems over the course of research cruises. Phytoplankton and particle size distribution (PSD) in the ocean is a key measurement, required in oceanographic research and ocean optics. Using a data set collected in the North Atlantic, spanning different oceanic water types, we outline the differences observed in concurrent samples collected from two different flow-through systems: a permanently plumbed science seawater supply with an impeller pump, and an independent system with shorter, clean tubing runs and a diaphragm pump. We observed an average of 40% decrease in phytoplankton counts, and significant changes to the PSD in 10-45 µm range, when comparing impeller and diaphragm pump systems. Change in PSD seems to be more dependent on the type of the phytoplankton, than the size, with photosynthetic ciliates displaying the largest decreases in cell counts (78%). Comparison of chlorophyll concentrations across the two systems demonstrated lower sensitivity to sampling system type. Observed changes in several measured biogeochemical parameters (associated with phytoplankton size distribution) using the two sampling systems, should be used as a guide towards building best practices when it comes to the deployment of flow-through systems in the field for examining optics and biogeochemistry. Using optical models, we evaluated potential impact of the observed change in measured phytoplankton size spectra onto scattering measurements, resulting in significant differences between modeled optical properties across systems (~40%). Researchers should be aware of the methods used with previously collected data sets, and take into consideration the potentially significant and highly variable ecosystem-dependent biases in designing field studies in the future.
Peterson, David A.; Zumberge, Jeremy R.
2006-01-01
Samples of benthic macroinvertebrates were collected side-by-side from riffles at 12 stream sites in Wyoming, Colorado, and Montana during 2000-2001, following protocols established by the U.S. Geological Survey National Water-Quality Assessment (NAWQA) Program and the U.S. Environmental Protection Agency Environmental Monitoring and Assessment Program (EMAP). Samples from riffles were collected following NAWQA protocols, using a sampler with 425-micron net mesh-opening size from a total area of 1.25 m2 per sample in multiple riffles. Samples also were collected following EMAP protocols, using a sampler with 500-micron net mesh-opening size from a total area of 0.72 m2 per sample in multiple riffles. The taxonomic identification and enumeration of the samples followed procedures established for each program. Benthic macroinvertebrate community structure was compared between the data sets using individual metrics, a multimetric index, and multivariate analysis. Comparisons between the macroinvertebrate community structures were made after sequentially adjusting both data sets for: (1) ambiguous taxa, (2) taxonomic inconsistencies, and (3) differences in laboratory subsampling. After removal of ambiguous taxa, pair-wise differences in total taxa richness and Ephemeroptera taxa richness were statistically significant (p < 0.05). Differences between the data sets generally were not significant for richness of other taxa, tolerant taxa, semi-voltine taxa, functional feeding groups, diversity, and dominance. Sample scores calculated using the Wyoming Stream Integrity Index were not significantly different between the two data sets. After reconciling both data sets for taxonomic inconsistencies, total taxa richness and Ephemeroptera taxa richness remained significantly different between the data sets. After adjusting the data for differences in laboratory subsampling, the differences in taxa richness were no longer significant. Bray-Curtis similarity coefficients and non-metric multi-dimensional scaling were used to examine macroinvertebrate community structure. Similarity in community structure between sites was affected to a greater extent by taxa reconciliation than by adjustment for subsampling.
Impact of particle size on distribution and human exposure of flame retardants in indoor dust.
He, Rui-Wen; Li, Yun-Zi; Xiang, Ping; Li, Chao; Cui, Xin-Yi; Ma, Lena Q
2018-04-01
The effect of dust particle size on the distribution and bioaccessibility of flame retardants (FRs) in indoor dust remains unclear. In this study, we analyzed 20 FRs (including 6 organophosphate flame retardants (OPFRs), 8 polybrominated diphenyl ethers (PBDEs), 4 novel brominated flame retardants (NBFRs), and 2 dechlorane plus (DPs)) in composite dust samples from offices, public microenvironments (PME), and cars in Nanjing, China. Each composite sample (one per microenvironment) was separated into 6 size fractions (F1-F6: 200-2000µm, 150-200µm, 100-150µm, 63-100µm, 43-63µm, and <43µm). FRs concentrations were the highest in car dust, being 16 and 6 times higher than those in offices and PME. The distribution of FRs in different size fractions was Kow-dependent and affected by surface area (Log Kow=1-4), total organic carbon (Log Kow=4-9), and FR migration pathways into dust (Log Kow>9). Bioaccessibility of FRs was measured by the physiologically-based extraction test, with OPFR bioaccessibility being 1.8-82% while bioaccessible PBDEs, NBFRs, and DPs were under detection limits due to their high hydrophobicity. The OPFR bioaccessibility in 200-2000µm fraction was significantly higher than that of <43µm fraction, but with no difference among the other four fractions. Risk assessment was performed for the most abundant OPFR-tris(2-chloroethyl) phosphate. The average daily dose (ADD) values were the highest for the <43µm fraction for all three types of dust using total concentrations, but no consistent trend was found among the three types of dust if based on bioaccessible concentrations. Our results indicated that dust size impacted human exposure estimation of FRs due to their variability in distribution and bioaccessibility among different fractions. For future risk assessment, size selection for dust sampling should be standardized and bioaccessibility of FRs should not be overlooked. Copyright © 2018 Elsevier Inc. All rights reserved.
Aaron Weiskittel; Jereme Frank; James Westfall; David Walker; Phil Radtke; David Affleck; David Macfarlane
2015-01-01
Tree biomass models are widely used but differ due to variation in the quality and quantity of data used in their development. We reviewed over 250 biomass studies and categorized them by species, location, sampled diameter distribution, and sample size. Overall, less than half of the tree species in Forest Inventory and Analysis database (FIADB) are without a...
Ait Kaci Azzou, Sadoune; Larribe, Fabrice; Froda, Sorana
2015-01-01
The effective population size over time (demographic history) can be retraced from a sample of contemporary DNA sequences. In this paper, we propose a novel methodology based on importance sampling (IS) for exploring such demographic histories. Our starting point is the generalized skyline plot with the main difference being that our procedure, skywis plot, uses a large number of genealogies. The information provided by these genealogies is combined according to the IS weights. Thus, we compute a weighted average of the effective population sizes on specific time intervals (epochs), where the genealogies that agree more with the data are given more weight. We illustrate by a simulation study that the skywis plot correctly reconstructs the recent demographic history under the scenarios most commonly considered in the literature. In particular, our method can capture a change point in the effective population size, and its overall performance is comparable with the one of the bayesian skyline plot. We also introduce the case of serially sampled sequences and illustrate that it is possible to improve the performance of the skywis plot in the case of an exponential expansion of the effective population size. PMID:26300910
ERIC Educational Resources Information Center
Galton, Maurice; Pell, Tony
2012-01-01
In a four-year study of the effect of class size on pupil outcomes in a sample of 36 primary schools in Hong Kong, it has been found that there are few positive differences in attainment between classes set at less than 25 pupils and those of normal size averaging 38. Three cohorts of pupils were studied. In Cohort 1 pupils spent 3 years in small…
On the influence of crystal size and wavelength on native SAD phasing.
Liebschner, Dorothee; Yamada, Yusuke; Matsugaki, Naohiro; Senda, Miki; Senda, Toshiya
2016-06-01
Native SAD is an emerging phasing technique that uses the anomalous signal of native heavy atoms to obtain crystallographic phases. The method does not require specific sample preparation to add anomalous scatterers, as the light atoms contained in the native sample are used as marker atoms. The most abundant anomalous scatterer used for native SAD, which is present in almost all proteins, is sulfur. However, the absorption edge of sulfur is at low energy (2.472 keV = 5.016 Å), which makes it challenging to carry out native SAD phasing experiments as most synchrotron beamlines are optimized for shorter wavelength ranges where the anomalous signal of sulfur is weak; for longer wavelengths, which produce larger anomalous differences, the absorption of X-rays by the sample, solvent, loop and surrounding medium (e.g. air) increases tremendously. Therefore, a compromise has to be found between measuring strong anomalous signal and minimizing absorption. It was thus hypothesized that shorter wavelengths should be used for large crystals and longer wavelengths for small crystals, but no thorough experimental analyses have been reported to date. To study the influence of crystal size and wavelength, native SAD experiments were carried out at different wavelengths (1.9 and 2.7 Å with a helium cone; 3.0 and 3.3 Å with a helium chamber) using lysozyme and ferredoxin reductase crystals of various sizes. For the tested crystals, the results suggest that larger sample sizes do not have a detrimental effect on native SAD data and that long wavelengths give a clear advantage with small samples compared with short wavelengths. The resolution dependency of substructure determination was analyzed and showed that high-symmetry crystals with small unit cells require higher resolution for the successful placement of heavy atoms.
NASA Technical Reports Server (NTRS)
Woods, D.
1980-01-01
The size distributions of particles in the exhaust plumes from the Titan rockets launched in August and September 1977 were determined from in situ measurements made from a small sampling aircraft that flew through the plumes. Two different sampling instruments were employed, a quartz crystal microbalance (QCM) cascade impactor and a forward scattering spectrometer probe (FSSP). The QCM measured the nonvolatile component of the aerosols in the plume covering an aerodynamic size ranging from 0.05 to 25 micrometers diameter. The FSSP, flown outside the aircraft under the nose section, measured both the liquid droplets and the solid particles over a size range from 0.5 to 7.5 micrometers in diameter. The particles were counted and classified into 15 size intervals. The presence of a large number of liquid droplets in the exhaust clouds is discussed and data are plotted for each launch and compared.
Anomalous small-angle scattering as a way to solve the Babinet principle problem
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boiko, M. E., E-mail: m.e.boiko@mail.ioffe.ru; Sharkov, M. D.; Boiko, A. M.
2013-12-15
X-ray absorption spectra (XAS) have been used to determine the absorption edges of atoms present in a sample under study. A series of small-angle X-ray scattering (SAXS) measurements using different monochromatic X-ray beams at different wavelengths near the absorption edges is performed to solve the Babinet principle problem. The sizes of clusters containing atoms determined by the method of XAS were defined in SAXS experiments. In contrast to differential X-ray porosimetry, anomalous SAXS makes it possible to determine sizes of clusters of different atomic compositions.
Anomalous small-angle scattering as a way to solve the Babinet principle problem
NASA Astrophysics Data System (ADS)
Boiko, M. E.; Sharkov, M. D.; Boiko, A. M.; Bobyl, A. V.
2013-12-01
X-ray absorption spectra (XAS) have been used to determine the absorption edges of atoms present in a sample under study. A series of small-angle X-ray scattering (SAXS) measurements using different monochromatic X-ray beams at different wavelengths near the absorption edges is performed to solve the Babinet principle problem. The sizes of clusters containing atoms determined by the method of XAS were defined in SAXS experiments. In contrast to differential X-ray porosimetry, anomalous SAXS makes it possible to determine sizes of clusters of different atomic compositions.
Soglia, Francesca; Gao, Jingxian; Mazzoni, Maurizio; Puolanne, Eero; Cavani, Claudio; Petracci, Massimiliano; Ertbjerg, Per
2017-09-01
Recently the poultry industry faced an emerging muscle abnormality termed wooden breast (WB), the prevalence of which has dramatically increased in the past few years. Considering the incomplete knowledge concerning this condition and the lack of information on possible variations due to the intra-fillet sampling locations (superficial vs. deep position) and aging of the samples, this study aimed at investigating the effect of 7-d storage of broiler breast muscles on histology, texture, and particle size distribution, evaluating whether the sampling position exerts a relevant role in determining the main features of WB. With regard to the histological observations, severe myodegeneration accompanied by accumulation of connective tissue was observed within the WB cases, irrespective of the intra-fillet sampling position. No changes in the histological traits took place during the aging in either the normal or the WB samples. As to textural traits, although a progressive tenderization process took place during storage (P ≤ 0.001), the differences among the groups were mainly detected when raw meat rather than cooked was analyzed, with the WB samples exhibiting the highest (P ≤ 0.001) 80% compression values. In spite of the increased amount of connective tissue components in the WB cases, their thermally labile cross-links will account for the similar compression and shear-force values as normal breast cases when measured on cooked samples. Similarly, the enlargement of extracellular matrix and fibrosis might contribute in explaining the different fragmentation patterns observed between the superficial and the deep layer in the WB samples, with the superficial part exhibiting a higher amount of larger particles and an increase in particles with larger size during storage, compared to normal breasts. © 2017 Poultry Science Association Inc.
Dos Santos, Fernanda Karina; Nevill, Allan; Gomes, Thayse Natacha Q F; Chaves, Raquel; Daca, Timóteo; Madeira, Aspacia; Katzmarzyk, Peter T; Prista, António; Maia, José A R
2016-05-01
Children from developed and developing countries have different anthropometric characteristics which may affect their motor performance (MP). To use the allometric approach to model the relationship between body size and MP in youth from two countries differing in socio-economic status-Portugal and Mozambique. A total of 2946 subjects, 1280 Mozambicans (688 girls) and 1666 Portuguese (826 girls), aged 10-15 years were sampled. Height and weight were measured and the reciprocal ponderal index (RPI) was computed. MP included handgrip strength, 1-mile run/walk, curl-ups and standing long jump tests. A multiplicative allometric model was adopted to adjust for body size differences across countries. Differences in MP between Mozambican and Portuguese children exist, invariably favouring the latter. The allometric models used to adjust MP for differences in body size identified the optimal body shape to be either the RPI or even more linear, i.e. approximately (height/mass(0.25)). Having adjusted the MP variables for differences in body size, the differences between Mozambican and Portuguese children were invariably reduced and, in the case of grip strength, reversed. These results reinforce the notion that significant differences exist in MP across countries, even after adjusting for differences in body size.
Altitudinal variation in age and body size in Yunnan pond frog (Pelophylax pleuraden).
Lou, Shang Ling; Jin, Long; Liu, Yan Hong; Mi, Zhi Ping; Tao, Gang; Tang, Yu Mei; Liao, Wen Bo
2012-08-01
Large-scale systematic patterns of body size are a basic concern of evolutionary biology. Identifying body size variation along altitudinal gradients may help us to understand the evolution of life history of animals. In this study, we investigated altitudinal variation in body size, age and growth rate in Chinese endemic frog, Pelophylax pleuraden. Data sampled from five populations covering an altitudinal span of 1413 to 1935 m in Sichuan province revealed that body size from five populations did not co-vary with altitudes, not following Bergmann's rule. Average adult SVL differed significantly among populations in males, but not in females. For both sexes, average adult age differed significantly among populations. Post-metamorphic growth rate did not co-vary with altitude, and females grew faster than males in all populations. When controlling the effect of age, body size did not differ among populations in both sexes, suggesting that age did not affect variation in body size among populations. For females, there may be other factors, such as the allocation of energy between growth and reproduction, that eliminated the effect of age on body size. To our minds, the major reason of body size variation among populations in male frogs may be related to individual longevity. Our findings also suggest that factors other than age and growth rate may contribute to size differences among populations.
NASA Astrophysics Data System (ADS)
Lari, L.; Wright, I.; Boyes, E. D.
2015-10-01
A very simple tomography sample holder at minimal cost was developed in-house. The holder is based on a JEOL single tilt fast exchange sample holder where its exchangeable tip was modified to allow high angle degree tilt. The shape of the tip was designed to retain mechanical stability while minimising the lateral size of the tip. The sample can be mounted on as for a standard 3mm Cu grids as well as semi-circular grids from FIB sample preparation. Applications of the holder on different sample systems are shown.
Stormer, Ame; Tun, Waimar; Harxhi, Arjan; Bodanovskaia, Zinaida; Yakovleva, Anna; Rusakova, Maia; Levina, Olga; Bani, Roland; Rjepaj, Klodian; Bino, Silva
2006-01-01
Injection drug users in Tirana, Albania and St. Petersburg, Russia were recruited into a study assessing HIV-related behaviors and HIV serostatus using Respondent Driven Sampling (RDS), a peer-driven recruitment sampling strategy that results in a probability sample. (Salganik M, Heckathorn DD. Sampling and estimation in hidden populations using respondent-driven sampling. Sociol Method. 2004;34:193–239). This paper presents a comparison of RDS implementation, findings on network and recruitment characteristics, and lessons learned. Initiated with 13 to 15 seeds, approximately 200 IDUs were recruited within 8 weeks. Information resulting from RDS indicates that social network patterns from the two studies differ greatly. Female IDUs in Tirana had smaller network sizes than male IDUs, unlike in St. Petersburg where female IDUs had larger network sizes than male IDUs. Recruitment patterns in each country also differed by demographic categories. Recruitment analyses indicate that IDUs form socially distinct groups by sex in Tirana, whereas there was a greater degree of gender mixing patterns in St. Petersburg. RDS proved to be an effective means of surveying these hard-to-reach populations. PMID:17075727
NASA Astrophysics Data System (ADS)
Raack, J.; Dennis, R.; Balme, M. R.; Taj-Eddine, K.; Ori, G. G.
2017-12-01
Dust devils are small vertical convective vortices which occur on Earth and Mars [1] but their internal structure is almost unknown. Here we report on in situ samples of two active dust devils in the Sahara Desert in southern Morocco [2]. For the sampling we used a 4 m high aluminium pipe with sampling areas made of removable adhesive tape. We took samples between 0.1-4 m with a sampling interval of 0.5 m and between 0.5-2 m with an interval of 0.25 m, respectively. The maximum diameter of all particles of the different sampling heights were then measured using an optical microscope to gain vertical grain size distributions and relative particle loads. Our measurements imply that both dust devils have a general comparable internal structure despite their different strengths and dimensions which indicates that the dust devils probably represents the surficial grain size distribution they move over. The particle sizes within the dust devils decrease nearly exponential with height which is comparable to results by [3]. Furthermore, our results show that about 80-90 % of the total particle load were lifted only within the first meter, which is a direct evidence for the existence of a sand skirt. If we assume that grains with a diameter <31 μm can go into suspension [4], our results show that only less than 0.1 wt% can be entrained into the atmosphere. Although this amount seems very low, these values represent between 60 and 70 % of all lifted particles due to the small grain sizes and their low weight. On Mars, the amount of lifted particles will be general higher as the dust coverage is larger [5], although the atmosphere can only suspend smaller grain sizes ( <20 μm) [6] compared to Earth. During our field campaign we observed numerous larger dust devils each day which were up to several hundred meters tall and had diameters of several tens of meters. This implies a much higher input of fine grained material into the atmosphere (which will have an influence on the climate, weather, and human health [7]) compared to the relative small dust devils sampled during our field campaign. [1] Thomas and Gierasch (1985) Science 230 [2] Raack et al. (2017) Astrobiology [3] Oke et al. (2007) J. Arid Environ. 71 [4] Balme and Greeley (2006) Rev. Geophys. 44 [5] Christensen (1986) JGR 91 [6] Newman et al. (2002) JGR 107 [7] Gillette and Sinclair (1990) Atmos. Environ. 24
Bøcher, Peder Klith; McCloy, Keith R
2006-02-01
In this investigation, the characteristics of the average local variance (ALV) function is investigated through the acquisition of images at different spatial resolutions of constructed scenes of regular patterns of black and white squares. It is shown that the ALV plot consistently peaks at a spatial resolution in which the pixels has a size corresponding to half the distance between scene objects, and that, under very specific conditions, it also peaks at a spatial resolution in which the pixel size corresponds to the whole distance between scene objects. It is argued that the peak at object distance when present is an expression of the Nyquist sample rate. The presence of this peak is, hence, shown to be a function of the matching between the phase of the scene pattern and the phase of the sample grid, i.e., the image. When these phases match, a clear and distinct peak is produced on the ALV plot. The fact that the peak at half the distance consistently occurs in the ALV plot is linked to the circumstance that the sampling interval (distance between pixels) and the extent of the sampling unit (size of pixels) are equal. Hence, at twice the Nyquist sampling rate, each fundamental period of the pattern is covered by four pixels; therefore, at least one pixel is always completely embedded within one pattern element, regardless of sample scene phase. If the objects in the scene are scattered with a distance larger than their extent, the peak will be related to the size by a factor larger than 1/2. This is suggested to be the explanation to the results presented by others that the ALV plot is related to scene-object size by a factor of 1/2-3/4.
Spatial and temporal variation of body size among early Homo.
Will, Manuel; Stock, Jay T
2015-05-01
The estimation of body size among the earliest members of the genus Homo (2.4-1.5Myr [millions of years ago]) is central to interpretations of their biology. It is widely accepted that Homo ergaster possessed increased body size compared with Homo habilis and Homo rudolfensis, and that this may have been a factor involved with the dispersal of Homo out of Africa. The study of taxonomic differences in body size, however, is problematic. Postcranial remains are rarely associated with craniodental fossils, and taxonomic attributions frequently rest upon the size of skeletal elements. Previous body size estimates have been based upon well-preserved specimens with a more reliable species assessment. Since these samples are small (n < 5) and disparate in space and time, little is known about geographical and chronological variation in body size within early Homo. We investigate temporal and spatial variation in body size among fossils of early Homo using a 'taxon-free' approach, considering evidence for size variation from isolated and fragmentary postcranial remains (n = 39). To render the size of disparate fossil elements comparable, we derived new regression equations for common parameters of body size from a globally representative sample of hunter-gatherers and applied them to available postcranial measurements from the fossils. The results demonstrate chronological and spatial variation but no simple temporal or geographical trends for the evolution of body size among early Homo. Pronounced body size increases within Africa take place only after hominin populations were established at Dmanisi, suggesting that migrations into Eurasia were not contingent on larger body sizes. The primary evidence for these marked changes among early Homo is based upon material from Koobi Fora after 1.7Myr, indicating regional size variation. The significant body size differences between specimens from Koobi Fora and Olduvai support the cranial evidence for at least two co-existing morphotypes in the Early Pleistocene of eastern Africa. Copyright © 2015 Elsevier Ltd. All rights reserved.
Yuchang, Jin; Junyi, Li; Junxiu, An; Jing, Wu; Mingcheng, He
2017-01-01
Traditional bullying and cyberbullying have become serious worldwide issues. The meta-analysis in this article took a cross-cultural perspective to explore whether there were any differences between the effects of cyber victimization and traditional victimization on the presence of depression and anxiety in children and adolescents and to examine the effects of moderators in explaining these differences/similarities. Fifty-six empirical studies (generating 148 independent samples) were included with a total sample size of 214,819 participants. The results indicated that the effects of cyber victimization and the subtypes of traditional victimization on anxiety were significantly different, and there was a marginally significant difference for depression. The moderating effects of country of origin were found to be significant for depression, with the mean effect size in North America being significantly higher than in China and Europe, which suggested that culture was an important factor. The moderating effects of age were also found to be significant for the relationships between traditional victimization and depression, traditional victimization and anxiety, cyber victimization and depression, and cyber victimization and anxiety. In addition, the effect size for cyber victimization and depression has increased in more recent publication years.
NASA Astrophysics Data System (ADS)
Guerit, L.; Barrier, L.; Narteau, C.; Métivier, F.; Liu, Y.; Lajeunesse, E.; Gayer, E.; Malverti, L.; Meunier, P.; Ye, B.
2012-04-01
In gravel-beds rivers, sediments are sorted into patches of different grain-sizes. For single-thread streams, it has long been shown that this local granulometric sorting is closely linked to the channel morpho-sedimentary elements. For braided streams, this relation is still unclear. In such rivers, many observations of vertical sediment sorting has led to the definition of a surface and a subsurface layers. Because of this common stratification, methods for sampling gravel-bed rivers have been divided in two families. The surface layer is generally sampled by surface methods and the subsurface layer by volumetric methods. Yet, the equivalency between the two kind of techniques is still a key question. In this study, we characterized the grain-size distribution of the surface layer of the Urumqi River, a shallow braided gravel-bed river in China, by surface-count (Wolman grid-by-number) and volumetric (sieve-by-weight) sampling methods. An analysis of two large samples (212 grains and 3226 kg) show that these two methods are equivalent to characterize the river-bed surface layer. Then, we looked at the grain-size distributions of the river-bed morpho-sedimentary elements: (1) chutes at flow constrictions, which pass downstream to (2) anabranches and (3) bars at flow expansions. Using both sampling methods, we measured the diameter of more than 2300 grains and weight more than 6000 kg of grains larger than 4 mm. Our results show that the three morpho-sedimentary elements correspond only to two kinds of grain-size patches: (1) chutes composed of one coarse-grained top layer lying on finer deposits, and (2) anabranches and bars made up of finer-grained deposits more homogeneous in depth. On the basis of these quantitative observations, together with the concave or convex morphology of the different elements, we propose that chute patches form by erosion and transit with size-selective entrainment, whereas anabranch and bar patches rather develop and migrate by transit and deposition. These patch features may be typical of shallow braided gravel-bed rivers and should be considered in future works about on bedload transport processes and their geomorphologic and stratigraphic results.
Stoichiometry of Cd(S,Se) nanocrystals by anomalous small-angle x-ray scattering
NASA Astrophysics Data System (ADS)
Ramos, Aline; Lyon, Olivier; Levelut, Claire
1995-12-01
In Cd(S,Se)-doped glasses the optical properties are strongly dependent on the size of the nanocrystals, but can be also largely modified by changes in the crystal stoichiometry; however, the information on both stoichiometry and size is difficult to obtain in crystals smaller than 10 nm. The intensity scattered at small angles is classically used to get information about nanoparticles sizes. Moreover the variation of amplitude of this intensity with the energy of the x ray—``the anomalous effect''—near the selenium edge is related to stoichiometry. Anomalous small-angle x-ray scattering has been used as a tentative method to get information about stoichiometry in nanocrystals with size lower than 10 nm. Experiments have been performed on samples treated for 2 days at temperatures in the range 540-650 °C. The samples treated at temperatures above 580 °C contain crystals with size larger than 4 nm. For all these samples the anomalous effect has nearly the same amplitude, and we found the stoichiometry x=0.4 for the CdSxSe1-x nanocrystals. This agrees with the previous results obtained by scanning electron microscopy and Raman spectroscopy. The results are also confirmed by measurements of the position of the optical absorption edge and by wide-angle x-ray scattering experiments. For the sample treated at 560 °C, the nanocrystal size is 3 nm and the stoichiometry x=0.6 is deduced from the anomalous effect. For samples treated at lower temperatures the anomalous effect is not observable, indicating an even lower selenium content in the nanocrystals (x≳0.7). We observed differences in the Se content of nanocrystals for different heat treatments of the same initial glass. These results may be very helpful to interpret the change in the optical properties when the temperature of the treatments decreases in the range 560-590 °C. In this temperature range, compositional effects seem to be of the same order of magnitude as the effects of the quantum confinement.
NASA Astrophysics Data System (ADS)
Bolling, Denzell Tamarcus
A significant amount of research has been devoted to the characterization of new engineering materials. Searching for new alloys which may improve weight, ultimate strength, or fatigue life are just a few of the reasons why researchers study different materials. In support of that mission this study focuses on the effects of specimen geometry and size on the dynamic failure of AA2219 aluminum alloy subjected to impact loading. Using the Split Hopkinson Pressure Bar (SHPB) system different geometric samples including cubic, rectangular, cylindrical, and frustum samples are loaded at different strain rates ranging from 1000s-1 to 6000s-1. The deformation properties, including the potential for the formation of adiabatic shear bands, of the different geometries are compared. Overall the cubic geometry achieves the highest critical strain and the maximum stress values at low strain rates and the rectangular geometry has the highest critical strain and the maximum stress at high strain rates. The frustum geometry type consistently achieves the lowest the maximum stress value compared to the other geometries under equal strain rates. All sample types clearly indicated susceptibility to strain localization at different locations within the sample geometry. Micrograph analysis indicated that adiabatic shear band geometry was influenced by sample geometry, and that specimens with a circular cross section are more susceptible to shear band formation than specimens with a rectangular cross section.
Study of structural and magnetic properties of melt spun Nd2Fe13.6Zr0.4B ingot and ribbon
NASA Astrophysics Data System (ADS)
Amin, Muhammad; Siddiqi, Saadat A.; Ashfaq, Ahmad; Saleem, Murtaza; Ramay, Shahid M.; Mahmood, Asif; Al-Zaghayer, Yousef S.
2015-12-01
Nd2Fe13.6Zr0.4B hard magnetic material were prepared using arc-melting technique on a water-cooled copper hearth kept under argon gas atmosphere. The prepared samples, Nd2Fe13.6Zr0.4B ingot and ribbon are characterized using X-ray diffraction (XRD), scanning electron microscopy (SEM) for crystal structure determination and morphological studies, respectively. The magnetic properties of the samples have been explored using vibrating sample magnetometer (VSM). The lattice constants slightly increased due to the difference in the ionic radii of Fe and that of Zr. The bulk density decreased due to smaller molar weight and low density of Zr as compared to that of Fe. Ingot sample shows almost single crystalline phase with larger crystallite sizes whereas ribbon sample shows a mixture of amorphous and crystalline phases with smaller crystallite sizes. The crystallinity of the material was highly affected with high thermal treatments. Magnetic measurements show noticeable variation in magnetic behavior with the change in crystallite size. The sample prepared in ingot type shows soft while ribbon shows hard magnetic behavior.
Herrera, C; Morikawa, M I; Bello, M B; von Meyeren, M; Centeno, J Eusebio; Dufourq, P; Martinez, M M; Llorente, J
2014-03-15
Preimplantation genetic diagnosis (PGD) allows identifying genetic traits in early embryos. Because in some equine breeds, like Polo Argentino, females are preferred to males for competition, PGD can be used to determine the gender of the embryo before transfer and thus allow the production of only female pregnancies. This procedure could have a great impact on commercial embryo production programs. The present study was conducted to adapt gender selection by PGD to a large-scale equine embryo transfer program. To achieve this, we studied (i) the effect on pregnancy rates of holding biopsied embryos for 7 to 10 hours in holding medium at 32 °C before transfer, (ii) the effect on pregnancy rates of using embryos of different sizes for biopsy, and (iii) the efficiency of amplification by heating biopsies before polymerase chain reaction. Equine embryos were classified by size (≤300, 300-1000, and >1000 μm), biopsied, and transferred 1 to 2 or 7 to 10 hours after flushing. Some of the biopsy samples obtained were incubated for 10 minutes at 95 °C and the rest remained untreated. Pregnancy rates were recorded at 25 days of gestation; fetal gender was determined using ultrasonography and compared with PGD results. Holding biopsied embryos for 7 to 10 hours before transfer produced pregnancy rates similar to those for biopsied embryos transferred within 2 hours (63% and 57%, respectively). These results did not differ from pregnancy rates of nonbiopsied embryos undergoing the same holding times (50% for 7-10 hours and 63% for 1-2 hours). Pregnancy rates for biopsied and nonbiopsied embryos did not differ between size groups or between biopsied and nonbiopsied embryos within the same size group (P > 0.05). Incubating biopsy samples for 10 minutes at 95 °C before polymerase chain reaction significantly increased the diagnosis rate (78.5% vs. 45.5% for treated and nontreated biopsy samples respectively). Gender determination using incubated biopsy samples matched the results obtained using ultrasonography in all pregnancies assessed (11/11, 100%); untreated biopsy samples were correctly diagnosed in 36 of 41 assessed pregnancies (87.8%), although the difference between treated and untreated biopsy samples was not significant. Our results demonstrated that biopsied embryos can remain in holding medium before being transferred, until gender diagnosis by PGD is complete (7-10 hours), without affecting pregnancy rates. This simplifies the management of an embryo transfer program willing to incorporate PGD for gender selection, by transferring only embryos of the desired sex. Embryo biopsy can be performed in a clinical setting on embryos of different sizes, without affecting their viability. Additionally, we showed that pretreating biopsy samples with a short incubation at 95 °C improved the overall efficiency of embryo sex determination. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Baiyegunhi, Christopher; Liu, Kuiwu; Gwavava, Oswald
2017-11-01
Grain size analysis is a vital sedimentological tool used to unravel the hydrodynamic conditions, mode of transportation and deposition of detrital sediments. In this study, detailed grain-size analysis was carried out on thirty-five sandstone samples from the Ecca Group in the Eastern Cape Province of South Africa. Grain-size statistical parameters, bivariate analysis, linear discriminate functions, Passega diagrams and log-probability curves were used to reveal the depositional processes, sedimentation mechanisms, hydrodynamic energy conditions and to discriminate different depositional environments. The grain-size parameters show that most of the sandstones are very fine to fine grained, moderately well sorted, mostly near-symmetrical and mesokurtic in nature. The abundance of very fine to fine grained sandstones indicate the dominance of low energy environment. The bivariate plots show that the samples are mostly grouped, except for the Prince Albert samples that show scattered trend, which is due to the either mixture of two modes in equal proportion in bimodal sediments or good sorting in unimodal sediments. The linear discriminant function analysis is dominantly indicative of turbidity current deposits under shallow marine environments for samples from the Prince Albert, Collingham and Ripon Formations, while those samples from the Fort Brown Formation are lacustrine or deltaic deposits. The C-M plots indicated that the sediments were deposited mainly by suspension and saltation, and graded suspension. Visher diagrams show that saltation is the major process of transportation, followed by suspension.
Analysis of spatial distribution of land cover maps accuracy
NASA Astrophysics Data System (ADS)
Khatami, R.; Mountrakis, G.; Stehman, S. V.
2017-12-01
Land cover maps have become one of the most important products of remote sensing science. However, classification errors will exist in any classified map and affect the reliability of subsequent map usage. Moreover, classification accuracy often varies over different regions of a classified map. These variations of accuracy will affect the reliability of subsequent analyses of different regions based on the classified maps. The traditional approach of map accuracy assessment based on an error matrix does not capture the spatial variation in classification accuracy. Here, per-pixel accuracy prediction methods are proposed based on interpolating accuracy values from a test sample to produce wall-to-wall accuracy maps. Different accuracy prediction methods were developed based on four factors: predictive domain (spatial versus spectral), interpolation function (constant, linear, Gaussian, and logistic), incorporation of class information (interpolating each class separately versus grouping them together), and sample size. Incorporation of spectral domain as explanatory feature spaces of classification accuracy interpolation was done for the first time in this research. Performance of the prediction methods was evaluated using 26 test blocks, with 10 km × 10 km dimensions, dispersed throughout the United States. The performance of the predictions was evaluated using the area under the curve (AUC) of the receiver operating characteristic. Relative to existing accuracy prediction methods, our proposed methods resulted in improvements of AUC of 0.15 or greater. Evaluation of the four factors comprising the accuracy prediction methods demonstrated that: i) interpolations should be done separately for each class instead of grouping all classes together; ii) if an all-classes approach is used, the spectral domain will result in substantially greater AUC than the spatial domain; iii) for the smaller sample size and per-class predictions, the spectral and spatial domain yielded similar AUC; iv) for the larger sample size (i.e., very dense spatial sample) and per-class predictions, the spatial domain yielded larger AUC; v) increasing the sample size improved accuracy predictions with a greater benefit accruing to the spatial domain; and vi) the function used for interpolation had the smallest effect on AUC.
Identification of missing variants by combining multiple analytic pipelines.
Ren, Yingxue; Reddy, Joseph S; Pottier, Cyril; Sarangi, Vivekananda; Tian, Shulan; Sinnwell, Jason P; McDonnell, Shannon K; Biernacka, Joanna M; Carrasquillo, Minerva M; Ross, Owen A; Ertekin-Taner, Nilüfer; Rademakers, Rosa; Hudson, Matthew; Mainzer, Liudmila Sergeevna; Asmann, Yan W
2018-04-16
After decades of identifying risk factors using array-based genome-wide association studies (GWAS), genetic research of complex diseases has shifted to sequencing-based rare variants discovery. This requires large sample sizes for statistical power and has brought up questions about whether the current variant calling practices are adequate for large cohorts. It is well-known that there are discrepancies between variants called by different pipelines, and that using a single pipeline always misses true variants exclusively identifiable by other pipelines. Nonetheless, it is common practice today to call variants by one pipeline due to computational cost and assume that false negative calls are a small percent of total. We analyzed 10,000 exomes from the Alzheimer's Disease Sequencing Project (ADSP) using multiple analytic pipelines consisting of different read aligners and variant calling strategies. We compared variants identified by using two aligners in 50,100, 200, 500, 1000, and 1952 samples; and compared variants identified by adding single-sample genotyping to the default multi-sample joint genotyping in 50,100, 500, 2000, 5000 and 10,000 samples. We found that using a single pipeline missed increasing numbers of high-quality variants correlated with sample sizes. By combining two read aligners and two variant calling strategies, we rescued 30% of pass-QC variants at sample size of 2000, and 56% at 10,000 samples. The rescued variants had higher proportions of low frequency (minor allele frequency [MAF] 1-5%) and rare (MAF < 1%) variants, which are the very type of variants of interest. In 660 Alzheimer's disease cases with earlier onset ages of ≤65, 4 out of 13 (31%) previously-published rare pathogenic and protective mutations in APP, PSEN1, and PSEN2 genes were undetected by the default one-pipeline approach but recovered by the multi-pipeline approach. Identification of the complete variant set from sequencing data is the prerequisite of genetic association analyses. The current analytic practice of calling genetic variants from sequencing data using a single bioinformatics pipeline is no longer adequate with the increasingly large projects. The number and percentage of quality variants that passed quality filters but are missed by the one-pipeline approach rapidly increased with sample size.
A Comparison Study of Normal-Incidence Acoustic Impedance Measurements of a Perforate Liner
NASA Technical Reports Server (NTRS)
Schultz, Todd; Liu, Fei; Cattafesta, Louis; Sheplak, Mark; Jones, Michael
2009-01-01
The eduction of the acoustic impedance for liner configurations is fundamental to the reduction of noise from modern jet engines. Ultimately, this property must be measured accurately for use in analytical and numerical propagation models of aircraft engine noise. Thus any standardized measurement techniques must be validated by providing reliable and consistent results for different facilities and sample sizes. This paper compares normal-incidence acoustic impedance measurements using the two-microphone method of ten nominally identical individual liner samples from two facilities, namely 50.8 mm and 25.4 mm square waveguides at NASA Langley Research Center and the University of Florida, respectively. The liner chosen for this investigation is a simple single-degree-of-freedom perforate liner with resonance and anti-resonance frequencies near 1.1 kHz and 2.2 kHz, respectively. The results show that the ten measurements have the most variation around the anti-resonance frequency, where statistically significant differences exist between the averaged results from the two facilities. However, the sample-to-sample variation is comparable in magnitude to the predicted cross-sectional area-dependent cavity dissipation differences between facilities, providing evidence that the size of the present samples does not significantly influence the results away from anti-resonance.
Size effects on the magnetic properties of LaCoO3 nanoparticles
NASA Astrophysics Data System (ADS)
Wei, Q.; Zhang, T.; Wang, X. P.; Fang, Q. F.
2012-02-01
Magnetic properties of LaCoO3 nanoparticles prepared by a sol-gel method with average particle size (D) ranging from 20 to 500 nm are investigated. All samples exhibit obvious ferromagnetic transition. With decreasing particle size from 500 to 120 nm, the transition temperature Tc decreases slightly from 85 K, however Tc decreases dramatically when D ≤ 85 nm. Low-field magnetic moment at 10 K decreases with reduction of particle size, while the high-field magnetization exhibits a converse behavior, which is different with previous reports. The coercivity Hc decreases as the particle size is reduced. It is different with other nanosystems that no exchange bias effect is observed in nanosized LaCoO3 particles. These interesting results arise from the surface effect induced by sized effect and the structure change in LaCoO3 nanoparticles.
Constitutive Parameter Measurement Using Double Ridge Waveguide
2013-03-01
different microwave absorbers. The sample constructed by AFRL is a polymer known commercially as VeroP and was fabricated in a Polyjet 3D printer . The...local 3D printer resources. The acrylic was able to fit similarly to the AFRL sample. The absorber material was formed using laser cut plastic as a...samples. During the sample fabrication process, the 3D printer from Air Force Institute of Technology (AFIT) was used to verify the sample size. The