Macromolecular crystal growing system
NASA Technical Reports Server (NTRS)
Snyder, Robert S. (Inventor); Herren, Blair J. (Inventor); Carter, Daniel C. (Inventor); Yost, Vaughn H. (Inventor); Bugg, Charles E. (Inventor); Delucas, Lawrence J. (Inventor); Suddath, Fred L. (Inventor)
1991-01-01
A macromolecular crystal growing system especially designed for growing crystals in the low gravity of space as well as the gravity of earth includes at least one tray assembly, a carrier assembly which receives the tray, and a refrigeration-incubation module in which the carrier assembly is received. The tray assembly includes a plurality of sealed chambers with a plastic syringe and a plug means for the double tip of the syringe provided therein. Ganging mechanisms operate the syringes and plugs simultaneously in a precise and smooth operation. Preferably, the tray assemblies are mounted on ball bearing slides for smooth operation in inserting and removing the tray assemblies into the carrier assembly. The plugging mechanism also includes a loading control mechanism. A mechanism for leaving a syringe unplugged is also provided.
Protein crystal growth tray assembly
NASA Technical Reports Server (NTRS)
Carter, Daniel C. (Inventor); Miller, Teresa Y. (Inventor)
1992-01-01
A protein crystal growth tray assembly includes a tray that has a plurality of individual crystal growth chambers. Each chamber has a movable pedestal which carries a protein crystal growth compartment at an upper end. The several pedestals for each tray assembly are ganged together for concurrent movement so that the solutions in the various pedestal growth compartments can be separated from the solutions in the tray's growth chambers until the experiment is to be activated.
Columbia, OV-102, forward middeck locker experiments and meal tray assemblies
NASA Technical Reports Server (NTRS)
1982-01-01
Overall view of forward middeck locker shows Continuous Flow Electrophoresis System (CFES) experiment control and monitoring module and sample storage module (on port side) and Monodisperse Latex Reactor (MLR) (on starboard side). Water Dispenser Kit water gun (above CFES module) and meal tray assemblies covered with snack food packages and beverage containers appear around the two experiments. Thanks to a variety of juices and other food items, this array in the middeck probably represents the most colorful area onboard the Earth-orbiting Columbia, Orbiter Vehicle (OV) 102. Most of the meal items have been carefully fastened to meal tray assemblies (foodtrays) and locker doors (or both). What has not been attached by conventional methods has been safely 'tucked' under something heavy (note jacket shoved into space occupied MLR). MLR is making its second flight and is designed to test the flexibility of making large-size, monodisperse (same size), polystyrene latex micro-spheres using
STS-5 crewmembers with meal tray assembly on middeck
NASA Technical Reports Server (NTRS)
1982-01-01
Commander Brand (in dark blue shirt), Pilot Overmyer (left), and Mission Specialist (MS) Lenoir (right) conduct microgravity experiments with food containers and meal tray assemblies in front of middeck port side wall and side hatch. Brand prepares to eat as meal tray assembly floats above his chest and Overmeyer and Lenoir look on. Sign on port side wall is labeled STS-5 Message Board.
Ballasted photovoltaic module and module arrays
Botkin, Jonathan [El Cerrito, CA; Graves, Simon [Berkeley, CA; Danning, Matt [Oakland, CA
2011-11-29
A photovoltaic (PV) module assembly including a PV module and a ballast tray. The PV module includes a PV device and a frame. A PV laminate is assembled to the frame, and the frame includes an arm. The ballast tray is adapted for containing ballast and is removably associated with the PV module in a ballasting state where the tray is vertically under the PV laminate and vertically over the arm to impede overt displacement of the PV module. The PV module assembly can be installed to a flat commercial rooftop, with the PV module and the ballast tray both resting upon the rooftop. In some embodiments, the ballasting state includes corresponding surfaces of the arm and the tray being spaced from one another under normal (low or no wind) conditions, such that the frame is not continuously subjected to a weight of the tray.
Pilot Overmyer looks over food selections and experiments with beverage
1982-11-16
STS005-07-255 (19 Nov. 1982) --- Astronaut Robert F. Overmyer, STS-5 pilot, using beverage container and drinking straw secured in meal tray assembly (ASSY), experiments with microgravity characteristics of liquid on middeck in front of forward lockers. Overmyer also looks over packages of food attached to middeck lockers in meal tray assemblies. Carry-on food warmer appears overhead and other meal tray assemblies, personal hygiene mirror assembly, personal hygiene kit, and portrait of G.W.S. Abbey, Johnson Space Center's (JSC) Director of Flight Operations, appear on lockers. Photo credit: NASA
Pilot Overmyer looks over food selections and experiments with beverage
NASA Technical Reports Server (NTRS)
1982-01-01
Pilot Overmyer, using beverage container and drinking straw secured in meal tray assembly (ASSY), experiments with microgravity chararcteristics of liquid on middeck in front of forward lockers. Overmyer also looks over packages of food attached to middeck lockers in meal tray assemblies. Carry-on food warmer appears overhead and other meal tray assemblies, personal hygiene mirror assy, personal hygiene kit, and portrait of G.W.S. Abbey, JSC's Director of Flight Operations, appear on lockers.
Microelectrophoretic apparatus and process
NASA Technical Reports Server (NTRS)
Grunbaum, B. W. (Inventor)
1978-01-01
New gel tray and lid assemblies designed for use in conjunction with slotted electrophoretic membranes were developed to take advantage of recently improved microelectrophoretic accessories which include a multisample applicator capable of applying up to 10 samples consecutively or simultaneously, and a temperature control plate for dissipating the heat produced by electrophoresis in a gel. The trays and membranes can be marketed ready for use as electrophoretic media or impregnated with various specific substrates and dyes
NASA Technical Reports Server (NTRS)
Pippin, Gary
1997-01-01
This pictorial presentation reviews the post-flight analysis results from two type of hardware (tray clamp bolt heads and uhcre flight experiment tray walls) from the Long Duration Exposure Facility (LDEF). It will also discuss flight hardware for one upcoming (Effects of the Space Environment on Materials (ESEM) flight experiment), and two current flight experiments evaluating the performance of materials in space (Passive Optical Sample Assembly (POSA) 1&2 flight experiments. These flight experiments also are concerned with contamination effects which will also be discussed.
Commander Brand shaves in front of forward middeck lockers
NASA Technical Reports Server (NTRS)
1982-01-01
Commander Brand, wearing shorts, shaves in front of forward middeck lockers using personal hygiene mirror assembly (assy). Open modular locker single tray assy, Field Sequential (FS) crew cabin camera, communications kit assy mini headset (HDST) and HDST interface unit (HIU), personal hygiene kit, and meal tray assemblies appear in view.
Management of surgical instruments with radio frequency identification tags.
Kusuda, Kaori; Yamashita, Kazuhiko; Ohnishi, Akiko; Tanaka, Kiyohito; Komino, Masaru; Honda, Hiroshi; Tanaka, Shinichi; Okubo, Takashi; Tripette, Julien; Ohta, Yuji
2016-01-01
To prevent malpractices, medical staff has adopted inventory time-outs and/or checklists. Accurate inventory and maintenance of surgical instruments decreases the risk of operating room miscounting and malfunction. In our previous study, an individual management of surgical instruments was accomplished using Radio Frequency Identification (RFID) tags. The purpose of this paper is to evaluate a new management method of RFID-tagged instruments. The management system of RFID-tagged surgical instruments was used for 27 months in clinical areas. In total, 13 study participants assembled surgical trays in the central sterile supply department. While using the management system, trays were assembled 94 times. During this period, no assembly errors occurred. An instrument malfunction had occurred after the 19th, 56th, and 73 th uses, no malfunction caused by the RFID tags, and usage history had been recorded. Additionally, the time it took to assemble surgical trays was recorded, and the long-term usability of the management system was evaluated. The system could record the number of uses and the defective history of each surgical instrument. In addition, the history of the frequency of instruments being transferred from one tray to another was recorded. The results suggest that our system can be used to manage instruments safely. Additionally, the management system was acquired of the learning effect and the usability on daily maintenance. This finding suggests that the management system examined here ensures surgical instrument and tray assembly quality.
Electrphoretic Sample Excitation Light Assembly.
Li, Qingbo; Liu, Changsheng
2002-04-02
An automated electrophoretic system is disclosed. The system employs a capillary cartridge having a plurality of capillary tubes. The cartridge has a first array of capillary ends projecting from one side of a plate. The first array of capillary ends are spaced apart in substantially the same manner as the wells of a microtitre tray of standard size. This allows one to simultaneously perform capillary electrophoresis on samples present in each of the wells of the tray. The system includes a stacked, dual carrousel arrangement to eliminate cross-contamination resulting from reuse of the same buffer tray on consecutive executions from electrophoresis. The system also has a gel delivery module containing a gel syringe/a stepper motor or a high pressure chamber with a pump to quickly and uniformly deliver gel through the capillary tubes. The system further includes a multi-wavelength beam generator to generate a laser beam which produces a beam with a wide range of wavelengths. An off-line capillary reconditioner thoroughly cleans a capillary cartridge to enable simultaneous execution of electrophoresis with another capillary cartridge. The streamlined nature of the off-line capillary reconditioner offers the advantage of increased system throughput with a minimal increase in system cost.
STS-28 Columbia, OV-102, Mission Specialist Adamson eating on middeck
NASA Technical Reports Server (NTRS)
1989-01-01
On middeck, Mission Specialist (MS) James C. Adamson enjoys the rare opportunity of eating in a weightless environment as he flips a shrimp with a spoon. In the background is a second crewmember holding a meal tray assembly (food tray) and sleep restraints fastened to starboard wall.
Development of Sample Handling and Analytical Expertise For the Stardust Comet Sample Return
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bradley, J; Bajt, S; Brennan, S
NASA's Stardust mission returned to Earth in January 2006 with ''fresh'' cometary particles from a young Jupiter family comet. The cometary particles were sampled during the spacecraft flyby of comet 81P/Wild-2 in January 2004, when they impacted low-density silica aerogel tiles and aluminum foils on the sample tray assembly at approximately 6.1 km/s. This LDRD project has developed extraction and sample recovery methodologies to maximize the scientific information that can be obtained from the analysis of natural and man-made nano-materials of relevance to the LLNL programs.
STS-57 inflight maintenance (IFM) tool tray at Boeing FEPF bench review
NASA Technical Reports Server (NTRS)
1993-01-01
STS-57 inflight maintenance (IFM) tool tray is displayed on a table top during the bench review at Boeing's Flight Equipment Processing Facility (FEPF) located near JSC. The tool tray will be located on Endeavour's, Orbiter Vehicle (OV) 105's, middeck in forward locker MF57K and includes pinch bar, deadblow hammer, punch, inspection mirror, speed handle assembly, robbins wrench, adjustable wrench, vise grips, connector pliers, ACCU bypass connector, connector strap wrench, locker tool, and mechanical fingers. Photo taken by NASA JSC contract photographer Benny Benavides.
Integral Fast Reactor fuel pin processor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levinskas, D.
1993-01-01
This report discusses the pin processor which receives metal alloy pins cast from recycled Integral Fast Reactor (IFR) fuel and prepares them for assembly into new IFR fuel elements. Either full length as-cast or precut pins are fed to the machine from a magazine, cut if necessary, and measured for length, weight, diameter and deviation from straightness. Accepted pins are loaded into cladding jackets located in a magazine, while rejects and cutting scraps are separated into trays. The magazines, trays, and the individual modules that perform the different machine functions are assembled and removed using remote manipulators and master-slaves.
Integral Fast Reactor fuel pin processor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levinskas, D.
1993-03-01
This report discusses the pin processor which receives metal alloy pins cast from recycled Integral Fast Reactor (IFR) fuel and prepares them for assembly into new IFR fuel elements. Either full length as-cast or precut pins are fed to the machine from a magazine, cut if necessary, and measured for length, weight, diameter and deviation from straightness. Accepted pins are loaded into cladding jackets located in a magazine, while rejects and cutting scraps are separated into trays. The magazines, trays, and the individual modules that perform the different machine functions are assembled and removed using remote manipulators and master-slaves.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sikka, V.K.; Santella, M.L.; Viswanathan, S.
1998-08-01
This Cooperative Research and Development Agreement (CRADA) report deals with the development of nickel aluminide alloy for improved longer life heat-resistant fixture assemblies for batch and continuous pusher carburizing furnaces. The nickel aluminide development was compared in both coupon and component testing with the currently used Fe-Ni-Cr heat-resisting alloy known as HU. The specific goals of the CRADA were: (1) casting process development, (2) characterization and possible modification of the alloy composition to optimize its manufacturing ability and performance under typical furnace operating conditions, and (3) testing and evaluation of specimens and prototype fixtures. In support of the CRADA objectives,more » coupons of nickel aluminide and the HU alloy were installed in both batch and pusher furnaces. The coupons were taken from two silicon levels and contained welds made with two different filler compositions (IC-221LA and IC-221W). Both nickel-aluminide and HU coupons were removed from the batch and pusher carburizing furnace at time intervals ranging from one month to one year. The exposed coupons were cut and mounted for metallographic, hardness, and microprobe analysis. The results of the microstructural analysis have been transmitted to General Motors Corporation, Saginaw Division (Delphi Saginaw) through reports that were presented at periodic CRADA review meetings. Based on coupon testing and verification of the coupon results with the testing of trays, Delphi Saginaw moved forward with the use of six additional trays in a batch furnace and two assemblies in a pusher furnace. Fifty percent of the trays and fixtures are in the as-cast condition and the remaining trays and fixtures are in the preoxidized condition. The successful operating experience of two assemblies in the pusher furnace for nearly a year formed the basis for a production run of 63 more assemblies. The production run required melting of 94 heats weighing 500 lb. each. Twenty-six of the 94 heats were from virgin stock, and 68 were from the revert that used 50% virgin and 50% revert. Detailed chemical analysis of the 94 heats reflected that the nickel aluminide can be cast into heat-treat fixtures under production conditions. In addition to the chemical analysis, the castings showed excellent dimensional reproducibility. A total of six batch furnace trays and 65 pusher furnace assemblies of nickel aluminide alloy IC-221M are currently operating in production furnaces at Delphi Saginaw. Two of the pusher furnace assemblies have completed two years of service without any failure. The CRADA has accomplished the goal of demonstrating that the nickel aluminide can be produced under commercial production conditions and it has superior performance over the currently used HU alloy in both batch and pusher furnaces.« less
Results of EVA/mobile transporter space station truss assembly tests
NASA Technical Reports Server (NTRS)
Watson, Judith J.; Heard, Walter L., Jr.; Bush, Harold G.; Lake, M. S.; Jensen, J. K.; Wallsom, R. E.; Phelps, J. E.
1988-01-01
Underwater neutral buoyance tests were conducted to evaluate the use of a Mobile Transporter concept in conjunction with EVA astronauts to construct the Space Station Freedom truss structure. A three-bay orthogonal tetrahedral truss configuration with a 15 foot square cross section was repeatedly assembled by a single pair of pressure suited test subjects working from the Mobile Transporter astronaut positioning devices (mobile foot restraints). The average unit assembly time (which included integrated installation of utility trays) was 27.6 s/strut, or 6 min/bay. The results of these tests indicate that EVA assembly of space station size structures can be significantly enhanced when using a Mobile Transporter equipped with astronaut positioning devices. Rapid assembly time can be expected and are dependent primarily on the rate of translation permissible for on-orbit operations. The concept used to demonstate integrated installation of utility trays requires minimal EVA handling and consequentially, as the results show, has little impact on overall assembly time.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-07
... steel, fire and water resistant storage chests, gun safes, security safes, portable security safes, cash..., touchpads, plastic gun racks, keypad assemblies, panel lock assemblies, door backs, plastic trays, drawers..., wood gun shelf racks, cable assemblies, communication cables, gasket kits, door springs, metal handles...
NASA Technical Reports Server (NTRS)
Heard, Walter L., Jr.; Watson, Judith J.; Lake, Mark S.; Bush, Harold G.; Jensen, J. Kermit; Wallsom, Richard E.; Phelps, James E.
1992-01-01
Results are presented from a ground test program of an alternate mobile transporter (MT) concept and extravehicular activity (EVA) assembly procedure for the Space Station Freedom (SSF) truss keel. A three-bay orthogonal tetrahedral truss beam consisting of 44 2-in-diameter struts and 16 nodes was assembled repeatedly in neutral buoyancy by pairs of pressure-suited test subjects working from astronaut positioning devices (APD's) on the MT. The truss bays were cubic with edges 15 ft long. All the truss joint hardware was found to be EVA compatible. The average unit assembly time for a single pair of experienced test subjects was 27.6 sec/strut, which is about half the time derived from other SSF truss assembly tests. A concept for integration of utility trays during truss assembly is introduced and demonstrated in the assembly tests. The concept, which requires minimal EVA handling of the trays, is shown to have little impact on overall assembly time. The results of these tests indicate that by using an MT equipped with APD's, rapid EVA assembly of a space station-size truss structure can be expected.
STS-45 blue shift crewmembers enjoy eating a meal on OV-104's middeck
NASA Technical Reports Server (NTRS)
1992-01-01
STS-45 Commander Charles F. Bolden retrieves a straw from his meal tray assembly secured on the middeck ceiling as other blue shift crewmembers around him enjoy eating their meals. Below Bolden, Pilot Brian Duffy balances a meal tray assembly on his lap as a food package and spoon freefloat between his hands. Payload Specialist Dirk D. Frimout, holding a food package and a spoon, steadies himself while eating by positioning his feet under a forward locker handhold strap. In the background, Mission Specialist (MS) and Payload Commander (PLC) Kathryn D. Sullivan prepares to take a bite of food.
FUEL SUBASSEMBLY CONSTRUCTION FOR RADIAL FLOW IN A NUCLEAR REACTOR
Treshow, M.
1962-12-25
An assembly of fuel elements for a boiling water reactor arranged for radial flow of the coolant is described. The ingress for the coolant is through a central header tube, perforated with parallel circumferertial rows of openings each having a lip to direct the coolant flow downward. Around the central tube there are a number of equally spaced concentric trays, closely fitiing the central header tube. Cylindrical fuel elements are placed in a regular pattern around the central tube, piercing the trays. A larger tube encloses the arrangement, with space provided for upward flow of coolart beyond the edge of the trays. (AEC)
Rapid Assembly Module for Traypacks
2006-01-01
napkins , trays, utensils, garbage bags, etc. Food items will be dry, canned, or other retorted goods that are shelf-stable and require no...marked on the floor of the container with ink . When an alternative configuration is selected, a new manual will be issued by the PI. The revised manual...50 solders one meal. Accessories will include such items as cups, napkins , trays, utensils, garbage bags, etc. Food items will be dry, canned, or
STS-5 Columbia, OV-102, middeck documentation
NASA Technical Reports Server (NTRS)
1982-01-01
Items stowed temporarily on forward middeck lockers include (left to right) field sequential (FS) crew cabin camera, procedural notebook, communications kit assembly (assy) headset (HDST) interface unit (HIU), personal hygiene kit, personal hygiene mirror assy, meal tray assemblies, towels, and Vestibular Study Experiment headset and antenna.
Installation and Assembly, Electrical Ground Support Equipment (GSE), Specification for
NASA Technical Reports Server (NTRS)
Denson, Erik C.
2014-01-01
This specification covers the general workmanship requirements and procedures for the complete installation and assembly of electrical ground support equipment (EGSE) such as terminal distributors, junction boxes, conduit and fittings, cable trays and accessories, interconnecting cables (including routing requirements), motor-control equipment, and necessary hardware as specified by the applicable contract and drawings.
Kulkarni, Rahul S.; Shah, Rupal J.; Chhajlani, Rahul; Saklecha, Bhuwan; Maru, Kavita
2017-01-01
Introduction The clinician’s skill, impression techniques, and materials play a very important role in recording fine details in an impression for accuracy of fixed partial denture prosthesis. Impression of prepared teeth and of the opposing arch can be recorded simultaneously by dual-arch trays, while the full arch metal trays are used for impressions of prepared teeth in one arch. Aim To measure and compare the accuracy of working dies made from impressions with metal and plastic dual arch trays and metal full arch trays, for two viscosities of impression material and by changing the sequence of pour of working and non-working sides. Materials and Methods A balanced design with independent samples was used to study the three variables (tray type, impression material viscosity, and pouring sequence). An impression made by dual arch trays and single arch trays were divided in to three groups (Group A-plastic dual arch tray, Group B-metal dual arch tray, Group C-full arch metal stock tray). Out of these three groups, two groups (Group A and B) were subdivided in to four subgroups each and one group (Group C) was subdivided in to two subgroups. A sample size of 30 was used in each subgroup yielding a total 300 impressions in three groups or ten subgroups. Impressions were made of a machined circular stainless steel die. All three dimensions (Occlusogingival, Mesiodistal, and Buccolingual) of the working dies as well as stainless steel standard die were measured three times, and the mean was used for the three standard sample values to which all working dies means were compared. Statistical analysis used for this study was a 3-factor analysis of variance with hypothesis testing at α =0.05. Results With respect to the selection of impression material viscosity statistically significant differences were found in the dies for the buccolingual and mesiodistal dimensions. Metal dual arch trays were slightly more accurate in the mesiodistal dimension in comparison to the plastic trays in reference of tray selection and in view of pouring sequence no differences were observed in occlusogingival dimension but in buccolingual and mesiodistal dimensions nonworking side was more accurate. Conclusion The gypsum dies produced from the dual arch impressions were generally smaller in all three dimensions than the stainless steel standard die. Plastic dual-arch trays were more accurate with rigid impression material and there was not statistically significant difference for sequence of pouring. Metal dual-arch trays were more accurate with monophase impression material and working side was more accurate. Stock metal full arch trays were more accurate for monophase impression material. PMID:28571280
Surface characterization of selected LDEF tray clamps
NASA Technical Reports Server (NTRS)
Cromer, T. F.; Grammer, H. L.; Wightman, J. P.; Young, Philip R.; Slemp, Wayne S.
1993-01-01
The surface characterization of chromic acid anodized 6061-T6 aluminum alloy tray clamps has shown differences in surface chemistry depending upon the position on the Long Duration Exposure Facility (LDEF). Water contact angle results showed no changes in wettability of the tray clamps. The overall surface topography of the control, trailing edge(E3) and leading edge(D9) samples was similar. The thickness of the aluminum oxide layer for all samples determined by Auger depth profiling was less than one micron. X-ray photoelectron spectroscopy (XPS) analysis of the tray clamps showed significant differences in the surface composition. Carbon and silicon containing compounds were the primary contaminants detected.
1977-01-01
trays are placed on a cart (206-pound net explosive). These carts are moved by driverless tractor to an 8-hour hold in a nearby building while quality...by driverless tractor to a 40-hour hold for quality assurance inspection. After inspection, the grenades are returned to the loading, assembling, and
Optimization test of the 2BSL-320 vegetable seeders with air-suction drum type
NASA Astrophysics Data System (ADS)
Tang, B.; Wang, Y. S.; Ji, S. Z.
2017-07-01
The seeding raising technology of the hole tray assembly line is an important part of modern agriculture. The 2BSL-320 vegetable seeders with air-suction drum type are implements that are used to fill nutritional soil and press a hole in a float tray to sow seeds precisely. It can complete the whole process of putting down the tray, bedding the soil, scraping the soil, pressing a hole, sowing the seeds, compacting the soil, watering and putting away the tray by one time. Based on the introduction of the structure and working principle of the implement’s critical components, in order to improve the seeding efficiency and the seeding accuracy of the seeders, the response surface tests and the group experiments were carried out in this paper. And the MATLAB tool box was used to conduct fitting and optimization analysis of the test results, also the rationality of the optimization results was validated by experiments, which had provided a theoretical basis for the design of operation parameters in the vegetable seeders and had improved the seeding efficiency and quality.
Protein Crystal Growth Apparatus for Microgravity
NASA Technical Reports Server (NTRS)
Carter, Daniel C. (Inventor); Dowling, Timothy E. (Inventor)
1997-01-01
Apparatus for growing protein crystals under microgravity environment includes a plurality of protein growth assemblies stacked one above the other within a canister. Each of the protein growth assemblies includes a tray having a number of spaced apart growth chambers recessed below an upper surface. the growth chambers each having an upstanding pedestal and an annular reservoir about the pedestal for receiving a wick and precipitating agents. A well is recessed below the top of each pedestal to define a protein crystal growth receptacle. A flexible membrane is positioned on the upper surface of each tray and a sealing plate is positioned above each membrane, each sealing plate having a number of bumpers corresponding in number and alignment to the pedestals for forcing the membrane selectively against the upper end of the respective pedestal to seal the reservoir and the receptacle when the sealing plate is forced down.
Spectral infrared hemispherical reflectance measurements for LDEF tray clamps
NASA Technical Reports Server (NTRS)
Wood, Bobby E.; Cromwell, Brian K.; Pender, Charles W.; Shepherd, Seth D.
1992-01-01
This paper describes infrared hemispherical reflectance measurements (2-15 microns) that were made on 58 chromic acid anodized tray clamps retrieved from the LDEF spacecraft. These clamps were used for maintaining the experiments in place and were located at various locations about the spacecraft. Changes in reflectance of the tray clamps at these locations were compared with atomic oxygen fluxes at the same locations. A decrease in absorption band depth was seen for the surfaces exposed to space indicating that there was some surface layer erosion. In all of the surfaces measured, little evidence of contamination was observed and none of the samples showed evidence of the brown nicotine stain that was so prominent in other experiments. Total emissivity values were calculated for both exposed and unexposed tray clamp surfaces. Only small differences, usually less than 1 percent, were observed. The spectral reflectances were measured using a hemi-ellipsoidal mirror reflectometer matched with an interferometer spectrometer. The rapid scanning capability of the interferometer allowed the reflectance measurements to be made in a timely fashion. The ellipsoidal mirror has its two foci separated by 2 inches and located on the major axis. A blackbody source was located at one focus while the tray clamp samples were located at the conjugate focus. The blackbody radiation was modulated and then focused by the ellipsoid onto the tray clamps. Radiation reflected from the tray clamp was sampled by the interferometer by viewing through a hole in the ellipsoid. A gold mirror (reflectance approximately 98 percent) was used as the reference surface.
Herbal dryer: drying of ginger (zingiber officinale) using tray dryer
NASA Astrophysics Data System (ADS)
Haryanto, B.; Hasibuan, R.; Alexander; Ashari, M.; Ridha, M.
2018-02-01
Drying is widely used as a method to preserve food because of its convenience and affordability. Drying of ginger using tray dryer were carried out at various drying conditions, such as air-drying flow, air-drying temperature, and sample dimensions, to achieve the highest drying rate. Samples with various dimensions were placed in the tray dryer and dried using various air-drying flow and temperatures. The weights of samples were observed every 3 minutes interval. Drying was stopped after three times of constant weighing. Data of drying was collected to make the drying curves. Drying curves show that the highest drying rate is achieved using highest air flow and temperature.
Recolonization of gravel habitats on Georges Bank (northwest Atlantic)
Collie, Jeremy S.; Hermsen, Jerome M.; Valentine, Page C.
2009-01-01
Gravel habitats on continental shelves around the world support productive fisheries but are also vulnerable to disturbance from bottom fishing. We conducted a 2-year in situ experiment to measure the rate of colonization of a gravel habitat on northern Georges Bank in an area closed to fishing (Closed Area II) since December 1994. Three large (0.25 m2) sediment trays containing defaunated pebble gravel were deployed at a study site (47 m water depth) in July 1997 and recovered in June 1999. The undersides of the tray lids positioned 56 cm above the trays served as settlement panels over the same time period. We observed rapid colonization of the gravel substrate (56 species) and the settlement panels (35 species), indicating that colonization of gravel in this region is not limited by the supply of colonists. The species composition of the taxa found in the trays was broadly similar to that we collected over a 10-year period (1994-2004) in dredge samples from gravel sediments at the same site. The increase in abundance of animals in the gravel colonization trays was rapid and reached a level in 2 years that took 4.5 years to achieve in the surrounding gravel sediments once fishing had stopped, based on data from dredge sampling at this site. The increase in biomass of animals found in the sediment trays paralleled the trend of biomass increase observed in dredge samples over the same period (1997-1999) but was lower in value. These data suggest that after rapid initial increase in abundance of organisms, succession proceeded by increasing individual body size. A comparison of settlement panel and tray faunas revealed that the mean biomass of structure-forming epifauna (sponges, bryozoans, anemones, hydroids, colonial tube worms) on the panels was 8 times that found on the trays. Structure-forming taxa constituted 29% of the mean biomass of the panel fauna but only 5.5% of the tray fauna. By contrast, the mean biomass of scavengers (crabs, echinoderms, nudibranchs, gastropods) in the trays was 32 times that on the panels. Colonization of the tray gravel was more rapid for free-living species (many of which are prey for fish) than for structure-forming epifauna, though colonists of the latter species were present. The reduced success of structure-forming species in colonizing the tray gravel possibly is related to factors such as intermittent burial of the gravel by migrating sand and low survival of new recruits due to the presence of high numbers of scavengers on the gravel. These two factors might explain, to varying degree, the slow recolonization of gravel habitats by structure-forming species in Closed Area II of the northern part of Georges Bank. ?? 2009 Elsevier Ltd.
Recolonization of gravel habitats on Georges Bank (northwest Atlantic)
NASA Astrophysics Data System (ADS)
Collie, Jeremy S.; Hermsen, Jerome M.; Valentine, Page C.
2009-09-01
Gravel habitats on continental shelves around the world support productive fisheries but are also vulnerable to disturbance from bottom fishing. We conducted a 2-year in situ experiment to measure the rate of colonization of a gravel habitat on northern Georges Bank in an area closed to fishing (Closed Area II) since December 1994. Three large (0.25 m 2) sediment trays containing defaunated pebble gravel were deployed at a study site (47 m water depth) in July 1997 and recovered in June 1999. The undersides of the tray lids positioned 56 cm above the trays served as settlement panels over the same time period. We observed rapid colonization of the gravel substrate (56 species) and the settlement panels (35 species), indicating that colonization of gravel in this region is not limited by the supply of colonists. The species composition of the taxa found in the trays was broadly similar to that we collected over a 10-year period (1994-2004) in dredge samples from gravel sediments at the same site. The increase in abundance of animals in the gravel colonization trays was rapid and reached a level in 2 years that took 4.5 years to achieve in the surrounding gravel sediments once fishing had stopped, based on data from dredge sampling at this site. The increase in biomass of animals found in the sediment trays paralleled the trend of biomass increase observed in dredge samples over the same period (1997-1999) but was lower in value. These data suggest that after rapid initial increase in abundance of organisms, succession proceeded by increasing individual body size. A comparison of settlement panel and tray faunas revealed that the mean biomass of structure-forming epifauna (sponges, bryozoans, anemones, hydroids, colonial tube worms) on the panels was 8 times that found on the trays. Structure-forming taxa constituted 29% of the mean biomass of the panel fauna but only 5.5% of the tray fauna. By contrast, the mean biomass of scavengers (crabs, echinoderms, nudibranchs, gastropods) in the trays was 32 times that on the panels. Colonization of the tray gravel was more rapid for free-living species (many of which are prey for fish) than for structure-forming epifauna, though colonists of the latter species were present. The reduced success of structure-forming species in colonizing the tray gravel possibly is related to factors such as intermittent burial of the gravel by migrating sand and low survival of new recruits due to the presence of high numbers of scavengers on the gravel. These two factors might explain, to varying degree, the slow recolonization of gravel habitats by structure-forming species in Closed Area II of the northern part of Georges Bank.
Electrode for electrochemical cell
Kaun, T.D.; Nelson, P.A.; Miller, W.E.
1980-05-09
An electrode structure for a secondary electrochemical cell includes an outer enclosure defining a compartment containing electrochemical active material. The enclosure includes a rigid electrically conductive metal sheet with perforated openings over major side surfaces. The enclosure can be assembled as first and second trays each with a rigid sheet of perforated electrically conductive metal at major side surfaces and normally extending flanges at parametric margins. The trays can be pressed together with moldable active material between the two to form an expandable electrode. A plurality of positive and negative electrodes thus formed are arranged in an alternating array with porous frangible interelectrode separators within the housing of the secondary electrochemical cell.
Electrode for electrochemical cell
Kaun, Thomas D.; Nelson, Paul A.; Miller, William E.
1981-01-01
An electrode structure for a secondary electrochemical cell includes an outer enclosure defining a compartment containing electrochemical active material. The enclosure includes a rigid electrically conductive metal sheet with perforated openings over major side surfaces. The enclosure can be assembled as first and second trays each with a rigid sheet of perforated electrically conductive metal at major side surfaces and normally extending flanges at parametric margins. The trays can be pressed together with moldable active material between the two to form an expandable electrode. A plurality of positive and negative electrodes thus formed are arranged in an alternating array with porous frangible interelectrode separators within the housing of the secondary electrochemical cell.
Mission Specialist (MS) Lenoir cuts Pilot Overmyer's hair on middeck
NASA Technical Reports Server (NTRS)
1982-01-01
Mission Specialist (MS) Lenoir, using hairbrush and scissors, cuts Pilot Overmyer's hair and trims his sideburns in front of forward middeck lockers. Personal hygiene kit (open), towels, meal tray assemblies, and field sequential (FS) crew cabincamera are attached to lockers.
Viscous-pendulum damper suppresses structural vibrations
NASA Technical Reports Server (NTRS)
Reed, W. H., III
1964-01-01
The viscous pendulum damper consists of a cylinder containing round trays on which round lead slugs rest. When assembled, the container is filled with a viscous liquid and attached, with axis vertical, to the structure. The device permits varying the damping of structural vibrations.
Stability of headspace volatiles in a ‘Fallglo’ tangerine juice matrix system at room temperature
USDA-ARS?s Scientific Manuscript database
Gas chromatography systems are usually equipped with autosamplers. Samples held in the autosampler tray can stay up to one day or longer at room temperature, if the tray is not equipped with a cooling mechanism. The objective of this research was to determine if holding samples at room temperature i...
Long Duration Exposure Facility experiment M0003 deintegration observation data base
NASA Technical Reports Server (NTRS)
Gyetvay, S. R.; Coggi, J. M.; Meshishnek, M. J.
1993-01-01
The four trays (2 leading edge and 2 trailing edge) of the M0003 materials experiment on the Long Duration Exposure Facility (LDEF) contained 1274 samples from 20 subexperiments. The complete sample complement represented a broad range of materials, including thin film optical coatings, paints, polymer sheets and tapes, adhesives, and composites, for use in various spacecraft applications, including thermal control, structures, optics, and solar power. Most subexperiments contained sets of samples exposed on both the leading and trailing edge trays of LDEF. Each individual sample was examined by high resolution optical microscope during the deintegration of the subexperiments from the M0003 trays. Observations of the post-flight condition of the samples made during this examination were recorded in a computer data base. The deintegration observation data base is available to requesters on floppy disk in 4th Dimension for the Macintosh format. Over 3,000 color macrographs and photomicrographs were shot to complement the observation records and to document the condition of the individual samples and of the M0003 trays. The photographs provide a visual comparison of the response of materials in leading and trailing edge LDEF environments. The Aerospace Corporate Archives is distributing photographs of the samples and hard copies of the database records to the general public upon request. Information on obtaining copies of the data base disks and for ordering photographs and records of specific samples or materials are given.
Pilot Fullerton prepares meal on middeck
1982-03-30
STS003-26-253 (30 March 1982) --- Astronaut Gordon Fullerton, STS-3 pilot, wearing communications kit assembly (assy) mini-headset (HDST), prepares meal on middeck. Fullerton clips corner of rehydratable food (cereal) package with scissors. The opening will allow Fullerton to insert JSC water dispenser kit water gun in order to heat contents with hot water. Meal tray assembly is secured to forward middeck locker and holds additional food packages and beverage containers. Photo credit: NASA
Pilot Fullerton plans menu as packaged food and beverages float around him
NASA Technical Reports Server (NTRS)
1982-01-01
Pilot C. Gordon Fullerton, wearing the communications carrier assembly (ASSY) mini headset (HDST), beings food preparation on the middeck. Canned goods, sealed packages, beverage containers, etc are attached with velcro to meal tray assemblies (secured on middeck forward lockers) and freefloat around Fullerton. JSC water dispenser kit and portrait of G.W.S. Abbey appears behind Fullerton on port side bulkhead and potable water tank appears below him.
Scooped Material on Rover Observation Tray
2012-10-25
Sample material from the fourth scoop of Martian soil collected by NASA Mars rover Curiosity is on the rover observation tray in this image taken during the mission 78th Martian sol, Oct. 24, 2012 by Curiosity left Navigation Camera.
Passive fit and accuracy of three dental implant impression techniques.
Al Quran, Firas A; Rashdan, Bashar A; Zomar, AbdelRahman A Abu; Weiner, Saul
2012-02-01
To reassess the accuracy of three impression techniques relative to the passive fit of the prosthesis. An edentulous maxillary cast was fabricated in epoxy resin with four dental implants embedded and secured with heat-cured acrylic resin. Three techniques were tested: closed tray, open tray nonsplinted, and open tray splinted. One light-cured custom acrylic tray was fabricated for each impression technique, and transfer copings were attached to the implants. Fifteen impressions for each technique were prepared with medium-bodied consistency polyether. Subsequently, the impressions were poured in type IV die stone. The distances between the implants were measured using a digital micrometer. The statistical analysis of the data was performed with ANOVA and a one-sample t test at a 95% confidence interval. The lowest mean difference in dimensional accuracy was found within the direct (open tray) splinted technique. Also, the one-sample t test showed that the direct splinted technique has the least statistical significant difference from direct nonsplinted and indirect (closed tray) techniques. All discrepancies were less than 100 Μm. Within the limitations of this study, the best accuracy of the definitive prosthesis was achieved when the impression copings were splinted with autopolymerized acrylic resin, sectioned, and rejoined. However, the errors associated with all of these techniques were less than 100 Μm, and based on the current definitions of passive fit, they all would be clinically acceptable.
2007-09-13
The instruments that make up the Ames Autonomous Module Scanner (AMS) that provided precise thermal-infrared imaging during the Western States Fire Mission in 2007 are detailed in this photo of the AMS as mounted on Ikhana's pod tray. The large foil-covered foam-insulated box at left covers the pressure vessel containing the data system computers and other electronics. The round white-topped assembly is the scan head, including the scan mirror, folded telescope, blackbody references, spectrometer and detectors. Two pressure boxes visible at the forward end of the tray contain the Applanix POS/AV precision navigation subsystem (black) and the power distributor including circuit breakers and ancillary wiring, scan motor controller and the blackbody reference temperature controller (blue).
Arora, Mansi; Kohli, Shivani; Kalsi, Rupali
2016-05-01
Dual arch impression technique signifies an essential improvement in fixed prosthodontics and has numerous benefits over conventional impression techniques. The accuracy of working dies fabricated from dual arch impression technique remains in question because there is little information available in the literature. This study was conducted to compare the accuracy of working dies fabricated from impressions made from two different viscosities of impression materials using metal, plastic dual arch trays and custom made acrylic trays. The study samples were grouped into two groups based on the viscosity of impression material used i.e. Group I (monophase), whereas Group II consisted of Dual Mix technique using a combination of light and heavy body material. These were further divided into three subgroups A, B and C depending on the type of impression tray used (metal dual arch tray, plastic dual arch tray and custom made tray). Measurements of the master cast were made using profile projector. Descriptive statistics like mean, Standard Deviation (SD) were calculated for all the groups. One way analysis of variance (ANOVA) was used for multiple group comparisons. A p-value of 0.05 or less was considered statistically significant. The gypsum dies obtained with the three types of impression trays using two groups of impression materials were smaller than the master models in dimensions. The plastic dual arch trays produced dies which were the least accurate of the three groups. There was no significant difference in the die dimensions obtained using the two viscosities of impression materials.
Kohli, Shivani; Kalsi, Rupali
2016-01-01
Introduction Dual arch impression technique signifies an essential improvement in fixed prosthodontics and has numerous benefits over conventional impression techniques. The accuracy of working dies fabricated from dual arch impression technique remains in question because there is little information available in the literature. Aim This study was conducted to compare the accuracy of working dies fabricated from impressions made from two different viscosities of impression materials using metal, plastic dual arch trays and custom made acrylic trays. Materials and Methods The study samples were grouped into two groups based on the viscosity of impression material used i.e. Group I (monophase), whereas Group II consisted of Dual Mix technique using a combination of light and heavy body material. These were further divided into three subgroups A, B and C depending on the type of impression tray used (metal dual arch tray, plastic dual arch tray and custom made tray). Measurements of the master cast were made using profile projector. Descriptive statistics like mean, Standard Deviation (SD) were calculated for all the groups. One way analysis of variance (ANOVA) was used for multiple group comparisons. A p-value of 0.05 or less was considered statistically significant. Results The gypsum dies obtained with the three types of impression trays using two groups of impression materials were smaller than the master models in dimensions. Conclusion The plastic dual arch trays produced dies which were the least accurate of the three groups. There was no significant difference in the die dimensions obtained using the two viscosities of impression materials. PMID:27437342
NASA Astrophysics Data System (ADS)
Zimmermann, M. W.; Gartenbach, K. E.; Kranz, A. R.
1994-10-01
This article highlights the first results of investigations on the general vitality and damage endpoints caused by cosmic ionizing radiation in dry, dormant plant seeds of the crucifer plant Arabidopsis thaliana (L.) Hennh. and the ascomycete Sordaria fimicola after 69 month stay in space. Wild-type and mutant gene marker lines were included in Free Flyer Biostack containers and exposed on earth and side tray of the LDEF-1 satellite. The damage in biological endpoints observed in the seeds increased in the side tray sample compared to the earth tray sample. For the ascospores we found different effects depending on the biological endpoints investigated for both expositions.
Zimmermann, M W; Gartenbach, K E; Kranz, A R
1994-10-01
This article highlights the first results of investigations on the general vitality and damage endpoints caused by cosmic ionizing radiation in dry, dormant plant seeds of the crucifer plant Arabidopsis thaliana (L.) Heynh. and the ascomycete Sordaria fimicola after 69 month stay in space. Wild-type and mutant gene marker lines were included in Free Flyer Biostack containers and exposed on earth and side tray of the LDEF-1 satellite. The damage in biological endpoints observed in the seeds increased in the side tray sample compared to the earth tray sample. For the ascospores we found different effects depending on the biological endpoints investigated for both expositions.
2007-02-20
ellipsome- try and reflectometry were employed to show that the silicon wafers gained about a 420-A-thick layer of a silica-like con- taminant with BRDF...under Contract No. FA8802-04-C-0001. 111°. Contents I. Introduction .1 2. Ellipsometry and Reflectometry ... NASA ) I ;d~ ~ ---- ! Y Figure 2. MISSE I PECI Tray 2 facing away from Soyuz. (Courtesy NASA ) Among the samples mounted in PEC I Tray 2 were several
2009-06-06
ISS020-E-007577 (6 June 2009) --- European Space Agency astronaut Frank De Winne, Expedition 20 flight engineer, returns a dewar tray to the Minus Eighty Laboratory Freezer for ISS (MELFI) after inserting biological samples into the trays in the Kibo laboratory of the International Space Station. Samples were taken as part of the Nutritional Status Assessment (Nutrition) with Repository experiment, a study done by NASA to date of human physiologic changes during long-duration spaceflight.
In vivo Study of the Accuracy of Dual-arch Impressions.
de Lima, Luciana Martinelli Santayana; Borges, Gilberto Antonio; Junior, Luiz Henrique Burnett; Spohr, Ana Maria
2014-06-01
This study evaluated in vivo the accuracy of metal (Smart®) and plastic (Triple Tray®) dual-arch trays used with vinyl polysiloxane (Flexitime®), in the putty/wash viscosity, as well as polyether (Impregum Soft®) in the regular viscosity. In one patient, an implant-level transfer was screwed on an implant in the mandibular right first molar, serving as a pattern. Ten impressions were made with each tray and impression material. The impressions were poured with Type IV gypsum. The width and height of the pattern and casts were measured in a profile projector (Nikon). The results were submitted to Student's t-test for one sample (α = 0.05). For the width distance, the plastic dual-arch trays with vinyl polysiloxane (4.513 mm) and with polyether (4.531 mm) were statistically wider than the pattern (4.489 mm). The metal dual-arch tray with vinyl polysiloxane (4.504 mm) and with polyether (4.500 mm) did not differ statistically from the pattern. For the height distance, only the metal dual-arch tray with polyether (2.253 mm) differed statistically from the pattern (2.310 mm). The metal dual-arch tray with vinyl polysiloxane, in the putty/wash viscosities, reproduced casts with less distortion in comparison with the same technique with the plastic dual-arch tray. The plastic or metal dual-arch trays with polyether reproduced cast with greater distortion. How to cite the article: Santayana de Lima LM, Borges GA, Burnett LH Jr, Spohr AM. In vivo study of the accuracy of dual-arch impressions. J Int Oral Health 2014;6(3):50-5.
2009-06-06
ISS020-E-007603 (7 June 2009) --- European Space Agency astronaut Frank De Winne, Expedition 20 flight engineer, removes a dewar tray from the Minus Eighty Laboratory Freezer for ISS (MELFI) in order to insert biological samples into the trays in the Kibo laboratory of the International Space Station. Samples were taken as part of the Nutritional Status Assessment (Nutrition) with Repository experiment, a study done by NASA to date of human physiologic changes during long-duration spaceflight.
Support for solar energy collectors
Cole, Corey; Ardell-Smith, Zachary; Ciasulli, John; Jensen, Soren
2016-11-01
A solar energy collection system can include support devices configured to accommodate misalignment of components during assembly. For example, the system can include piles fixed to the earth and an adjustable bearing assembly at the upper end of the pile. The adjustable bearing assembly can include at least one of a vertical adjustment device, a lateral adjustment device and an angular adjustment device. The solar energy collection system can also include a plurality of solar energy collection device pre-wired together and mounted to a support member so as to form modular units. The system can also include enhanced supports for wire trays extending between rows of solar energy collection devices.
Commander Young removes CAP from FDF stowage locker on middeck
NASA Technical Reports Server (NTRS)
1981-01-01
Commander Young removes Crew Activity Plans (CAP) from Flight Data File (FD/FDF) modular stowage locker single tray assembly located in forward middeck locker MF28E. Window shade and filter kit on port side bulkhead and potable water tank on middeck floor appear in view. Photo was taken by Pilot Crippen with a 35mm camera.
Spacecraft materials studies on the Aerospace Corporation tray on EOIM-3
NASA Technical Reports Server (NTRS)
Stuckey, Wayne K.; Hemminger, Carol S.; Steckel, Gary L.; Hills, Malina M.; Hilton, Michael R.
1995-01-01
A passive tray was flown on the Effects of Oxygen Interaction with Materials experiment on STS-46 (EOIM-3) with 82 samples from The Aerospace Corporation. A variety of advanced materials related to potential uses on future spacecraft were included for evaluation representing optical coatings, lubricants, polymers, composites, carbon-carbon composite protective coatings, graphite protective coatings, thermal-control materials, and some samples of current materials. An overview of the available results from the investigations of these materials is presented.
Wakata and Thirsk with MELFI in KIBO
2009-06-15
ISS020-E-010028 (15 June 2009) --- Japan Aerospace Exploration Agency (JAXA) astronaut Koichi Wakata, Expedition 20 flight engineer, returns a dewar tray to the Minus Eighty Laboratory Freezer for ISS (MELFI) after inserting biological samples into the trays in the Kibo laboratory of the International Space Station. Samples were taken as part of the Nutritional Status Assessment (Nutrition) with Repository experiment, a study done by NASA to date of human physiologic changes during long-duration spaceflight. Canadian Space Agency astronaut Robert Thirsk, flight engineer, assisted Wakata.
Definition study for an advanced cosmic ray experiment utilizing the long duration exposure facility
NASA Astrophysics Data System (ADS)
Price, P. B.
1982-06-01
To achieve the goals of cosmic ray astrophysics, an ultraheavy cosmic ray experiment on an LDEF reflight should be in an orbit with high inclination (approximately 57 deg) at approximately 230 nm for approximately 2 years near solar minimum (approximately 1986). It should fill 61 trays. Each tray should contain 4 modules of total active area 0.7 sq m, with a thermal blanket, thermal labyrinth mounts, aluminum honeycomb mechanical support, and total weight approximately 100 kg. Each module should contain interleaved CR39, Lexan, and thin copper sheets plus one event-thermometer canned in a thin metal cannister sealed with approximately 0.2 atm dry O2. The CR39 and Lexan should be manufactured to specifications and the sheet copper rolled to specifications. The event-thermometer should be a stiffened CR39 sheet that slides via bimetal strips relative to fixed CR39 sheet so that stack temperature can be read out for each event. The metal cannister can be collapsed at launch and landing, capturing the sliding assembly to prevent damage. An engineering study should be made of a prototype LDEF tray; this will include thermal and mechanical tests of detectors and the event thermometer.
Definition study for an advanced cosmic ray experiment utilizing the long duration exposure facility
NASA Technical Reports Server (NTRS)
Price, P. B.
1982-01-01
To achieve the goals of cosmic ray astrophysics, an ultraheavy cosmic ray experiment on an LDEF reflight should be in an orbit with high inclination (approximately 57 deg) at approximately 230 nm for approximately 2 years near solar minimum (approximately 1986). It should fill 61 trays. Each tray should contain 4 modules of total active area 0.7 sq m, with a thermal blanket, thermal labyrinth mounts, aluminum honeycomb mechanical support, and total weight approximately 100 kg. Each module should contain interleaved CR39, Lexan, and thin copper sheets plus one event-thermometer canned in a thin metal cannister sealed with approximately 0.2 atm dry O2. The CR39 and Lexan should be manufactured to specifications and the sheet copper rolled to specifications. The event-thermometer should be a stiffened CR39 sheet that slides via bimetal strips relative to fixed CR39 sheet so that stack temperature can be read out for each event. The metal cannister can be collapsed at launch and landing, capturing the sliding assembly to prevent damage. An engineering study should be made of a prototype LDEF tray; this will include thermal and mechanical tests of detectors and the event thermometer.
Wakata and Thirsk with MELFI in KIBO
2009-06-15
ISS020-E-010025 (15 June 2009) --- Japan Aerospace Exploration Agency (JAXA) astronaut Koichi Wakata, Expedition 20 flight engineer, removes a dewar tray from the Minus Eighty Laboratory Freezer for ISS (MELFI) in order to insert biological samples into the trays in the Kibo laboratory of the International Space Station. Samples were taken as part of the Nutritional Status Assessment (Nutrition) with Repository experiment, a study done by NASA to date of human physiologic changes during long-duration spaceflight. Canadian Space Agency astronaut Robert Thirsk, flight engineer, assisted Wakata.
Klebanoff, Leonard E.
2001-01-01
A seal assembly that provides a means for establishing multiple pressure zones within a system. The seal assembly combines a plate extending from the inner wall of a housing or inner enclosure that intersects with and is immersed in the fluid contained in a well formed in a tray contained within the enclosure. The fluid is a low vapor pressure oil, chemically inert and oxidation resistant. The use of a fluid as the sealing component provides a seal that is self-healing and mechanically robust not subject to normal mechanical wear, breakage, and formation of cracks or pinholes and decouples external mechanical vibrations from internal structural members.
Subgingival delivery of oral debriding agents: a proof of concept.
Dunlap, Tanya; Keller, Duane C; Marshall, Milton V; Costerton, J William; Schaudinn, Christoph; Sindelar, Betty; Cotton, John R
2011-01-01
This study is a proof of concept to determine the efficacy of a custom-fabricated tray in placing antimicrobial and debriding agents in the periodontal pockets of persons with active gingival infections. Localized subgingival delivery of antimicrobial and antibiotic agents is routinely employed as adjunctive therapy for the treatment and management ofperiopathogens associated with periodontal disease. Because these delivery techniques often face time constraints and impose temporary restrictions on patient brushing and flossing, a custom-formed prescription dental tray can be used to deliver and maintain medications in periodontal pockets between office visits and without brushing or flossing restrictions. The ability of this tray to maintain sufficient concentrations of medication in the periodontal pockets to have a therapeutic effect is evaluated here with theoretical modeling and practical application. Hydrogen peroxide is an oral debriding agent and oral wound cleanser with antimicrobial properties. The debriding effect of 1.7% hydrogen peroxide gel was tested in vitro on Streptococcus mutans biofilm using glass carriers for collection. Diffusion modeling tested the potential of the customized tray to place hydrogen peroxide gel into the sulcus in the presence of crevicular fluid flow. Changes in periodontal microflora with scanning electron microscopy analysis of in vivo paper point site sampling were analyzed before and after a thin ribbon of 1.7% hydrogen peroxide gel (approximately 0.7 gm) and a subtherapeutic dose (three drops) of Vibramycin (50 mg/5 ml) were placed via Perio Trays into periodontal pockets, ranging from 4-8 mm at daily prescribed intervals for two to five weeks. In vitro results indicate that 1.7% hydrogen peroxide gel breaks down the exopolysaccharide slime and cell walls ofS. mutans, and begins to debride the cells from glass carriers within 10 minutes. Diffusion modeling indicates that hydrogen peroxide can penetrate into the deeper pockets (9 mm), but also its concentration in these deep pockets will increase over wearing time in the absence of degradation by peroxidases and catalase. Site sampling data confirm diffusion modeling results, with evidence that medication delivered with the prescription tray reduced subgingival bacterial loads and enhanced healing of corresponding oral tissues. The prescription Perio Tray effectively placed medication in the gingival sulcus. Mathematical modeling indicated Perio Tray placement of hydrogen peroxide gel in periodontal pockets with depths up to 9 mm over 15 minutes treatment time was theoretically possible. Pathology reports reveal reductions in subgingival bacterial loads and improvements in pretreatment pocket depths of up to 8 mm after 1.7% hydrogen peroxide and Vibramycin Syrup were prescribed for use with the Perio Tray. The in vitro analysis indicating that hydrogen peroxide is the active and effective oral debriding agent needs to be confirmed with additional studies.
Ebadian, Behnaz; Rismanchian, Mansor; Dastgheib, Badrosadat; Bajoghli, Farshad
2015-01-01
Different factors such as impression techniques and materials can affect the passive fit between the superstructure and implant. The aim of this study was to determine the effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts. Four internal hex implants (Biohorizons Ø4 mm) were placed on a metal maxillary model perpendicular to the horizontal plane in maxillary lateral incisors, right canine and left first premolar areas. Three impression techniques including open tray, closed tray using ball top screw abutments and closed tray using short impression copings and two impression materials (polyether and polyvinyl siloxane) were evaluated (n = 60). The changes in distances between implant analogues in mediolateral (x) and anteroposterior (y) directions and analogue angles in x/z and y/z directions in the horizontal plane on the definitive casts were measured by coordinate measuring machine. The data were analyzed by multivariate two-way analysis of variance and one sample t-test (α = 0.05). No statistical significant differences were observed between different impression techniques and materials. However, deviation and distortion of definitive casts had a significant difference with the master model when short impression copings and polyvinyl siloxane impression material were used (P < 0.05). In open tray technique, there was a significant difference in the rotation of analogs compared with the master model with both impression materials (P < 0.05). There was no difference between open and closed tray impression techniques; however, less distortion and deviation were observed in the open tray technique. In the closed tray impression technique, ball top screw was more accurate than short impression copings.
Ebadian, Behnaz; Rismanchian, Mansor; Dastgheib, Badrosadat; Bajoghli, Farshad
2015-01-01
Background: Different factors such as impression techniques and materials can affect the passive fit between the superstructure and implant. The aim of this study was to determine the effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts. Materials and Methods: Four internal hex implants (Biohorizons Ø4 mm) were placed on a metal maxillary model perpendicular to the horizontal plane in maxillary lateral incisors, right canine and left first premolar areas. Three impression techniques including open tray, closed tray using ball top screw abutments and closed tray using short impression copings and two impression materials (polyether and polyvinyl siloxane) were evaluated (n = 60). The changes in distances between implant analogues in mediolateral (x) and anteroposterior (y) directions and analogue angles in x/z and y/z directions in the horizontal plane on the definitive casts were measured by coordinate measuring machine. The data were analyzed by multivariate two-way analysis of variance and one sample t-test (α = 0.05). Results: No statistical significant differences were observed between different impression techniques and materials. However, deviation and distortion of definitive casts had a significant difference with the master model when short impression copings and polyvinyl siloxane impression material were used (P < 0.05). In open tray technique, there was a significant difference in the rotation of analogs compared with the master model with both impression materials (P < 0.05). Conclusion: There was no difference between open and closed tray impression techniques; however, less distortion and deviation were observed in the open tray technique. In the closed tray impression technique, ball top screw was more accurate than short impression copings. PMID:25878678
Surgical instrument similarity metrics and tray analysis for multi-sensor instrument identification
NASA Astrophysics Data System (ADS)
Glaser, Bernhard; Schellenberg, Tobias; Franke, Stefan; Dänzer, Stefan; Neumuth, Thomas
2015-03-01
A robust identification of the instrument currently used by the surgeon is crucial for the automatic modeling and analysis of surgical procedures. Various approaches for intra-operative surgical instrument identification have been presented, mostly based on radio-frequency identification (RFID) or endoscopic video analysis. A novel approach is to identify the instruments on the instrument table of the scrub nurse with a combination of video and weight information. In a previous article, we successfully followed this approach and applied it to multiple instances of an ear, nose and throat (ENT) procedure and the surgical tray used therein. In this article, we present a metric for the suitability of the instruments of a surgical tray for identification by video and weight analysis and apply it to twelve trays of four different surgical domains (abdominal surgery, neurosurgery, orthopedics and urology). The used trays were digitized at the central sterile services department of the hospital. The results illustrate that surgical trays differ in their suitability for the approach. In general, additional weight information can significantly contribute to the successful identification of surgical instruments. Additionally, for ten different surgical instruments, ten exemplars of each instrument were tested for their weight differences. The samples indicate high weight variability in instruments with identical brand and model number. The results present a new metric for approaches aiming towards intra-operative surgical instrument detection and imply consequences for algorithms exploiting video and weight information for identification purposes.
NASA Technical Reports Server (NTRS)
Elberg, R.
1984-01-01
This experiment has three objectives. The first and main objective is to detect a possible variation in the coefficient of thermal expansion of composite samples during a 1-year exposure to the near-Earth orbital environment. A second objective is to detect a possible change in the mechanical integrity of composite products, both simple elements and honeycomb sandwich assemblies. A third objective is to compare the behavior of two epoxy resins commonly used in space structural production. The experimental approach is to passively expose samples of epoxy matrix composite materials to the space environment and to compare preflight and postflight measurements of mechanical properties. The experiment will be located in one of the three FRECOPA (French cooperative payload) boxes in a 12-in.-deep peripheral tray that contains nine other experiments from France. The FRECOPA box will protect the samples from contamination during the launch and reentry phases of the mission. The coefficients of thermal expansion are measured on Earth before and after space exposure.
Haghi, Hamidreza Rajati; Shiehzadeh, Masoud; Nakhaei, Mohammadreza; Ahrary, Fatemeh; Sabzevari, Saeid
2017-01-01
Introduction: A dental impression is a negative imprint of an oral structure that can be used to produce a positive cast of a patient's teeth as a permanent record. The accuracy of the impression affects the accuracy of the cast, and a precise impression is needed in order to create prosthesis with optimal fitting. Minimization of misfit is an important aim in prosthesis science and dental implants. The aim of this study was to evaluate the effects of the materials and techniques used to take an impression on the vertical misfit of implant-supported, screw-retained, three-unit bridges. Materials and Methods: The principal model used was an acrylic block with two ITI implants. A 1.5-mm abutment was attached to fixtures with torque of 25 N.cm. A base-metal framework was built on the abutment in the acrylic block. The abutments of the acrylic model were unscrewed and fixture-level impressions were made. The impression techniques included open/closed-tray techniques and the impression materials were polyether and polyvinyl siloxane. Forty acrylic custom trays were built for each impression. The marginal gap in the framework at three points (buccal, lingual, and distal) was measured using an optical microscope with ×250. Results: It is demonstrated that in all 360 evaluated samples, the mean vertical misfit in polyether samples of molar and premolar teeth was significantly lower than in polyvinyl siloxane (P < 0.001 and P = 0.017, respectively) in all three locations of the molar and lingual premolar examined (buccal, lingual, and distal), the mean vertical misfit of the polyether samples was significantly lower than those of polyvinyl siloxane (P < 0.01). On the other hand, although the mean vertical misfit using the open-tray technique in the molar teeth was significantly lower than with the closed-tray method (P = 0.002), no statistical difference was seen between the open-tray and closed-tray technique in general (P = 0.87). Conclusion: Within the limitations of this study, the following conclusions can be drawn: The impression method had no effect on marginal discrepancy of 3-unit screw retained fixed partial dentures. A higher marginal accuracy was obtained using polyether impression material compared to polyvinyl siloxane. PMID:28216844
EXPOSE-E: an ESA astrobiology mission 1.5 years in space.
Rabbow, Elke; Rettberg, Petra; Barczyk, Simon; Bohmeier, Maria; Parpart, André; Panitz, Corinna; Horneck, Gerda; von Heise-Rotenburg, Ralf; Hoppenbrouwers, Tom; Willnecker, Rainer; Baglioni, Pietro; Demets, René; Dettmann, Jan; Reitz, Guenther
2012-05-01
The multi-user facility EXPOSE-E was designed by the European Space Agency to enable astrobiology research in space (low-Earth orbit). On 7 February 2008, EXPOSE-E was carried to the International Space Station (ISS) on the European Technology Exposure Facility (EuTEF) platform in the cargo bay of Space Shuttle STS-122 Atlantis. The facility was installed at the starboard cone of the Columbus module by extravehicular activity, where it remained in space for 1.5 years. EXPOSE-E was returned to Earth with STS-128 Discovery on 12 September 2009 for subsequent sample analysis. EXPOSE-E provided accommodation in three exposure trays for a variety of astrobiological test samples that were exposed to selected space conditions: either to space vacuum, solar electromagnetic radiation at >110 nm and cosmic radiation (trays 1 and 3) or to simulated martian surface conditions (tray 2). Data on UV radiation, cosmic radiation, and temperature were measured every 10 s and downlinked by telemetry. A parallel mission ground reference (MGR) experiment was performed on ground with a parallel set of hardware and samples under simulated space conditions. EXPOSE-E performed a successful 1.5-year mission in space.
Comparison of Spacecraft Contamination Models with Well-Defined Flight Experiment
NASA Technical Reports Server (NTRS)
Pippin, G. H.
1998-01-01
The report presents analyzed surface areas on particular experiment trays from the Long Duration Exposure Facility (LDEF) for silicone-based molecular contamination. The trays for examination were part of the Ultra-Heavy Cosmic Ray Experiment (UHCRE). These particular trays were chosen because each tray was identical to the others in construction, and the materials on each tray were well known, documented, and characterized. In particular, a known specific source of silicone contamination was present on each tray. Only the exposure conditions varied from tray to tray. The results of post-flight analyses of surfaces of three trays were compared with the predictions of the three different spacecraft molecular contamination models. Phase one tasks included: 1) documenting the detailed geometry of the hardware; 2) determining essential properties of the anodized aluminum, Velcro(Tm), silverized Teflon(Tm), silicone gaskets, and DC6-1104(Tm) silicone adhesive materials used to make the trays, tray covers, and thermal control blankets; 3) selecting and removing areas from each tray; and 4) beginning surface analysis of the selected tray walls. Phase two tasks included: 1) completion of surface analysis measurements of the selected tray surface, 2) obtaining auger depth profiles at selected locations, and 3) running versions of the ISEM, MOFLUX, and PLIMP (Plume Impingement) contamination prediction models and making comparisons with experimental results.
Wei, L; Chen, H; Zhou, Y S; Sun, Y C; Pan, S X
2017-02-18
To compare the technician fabrication time and clinical working time of custom trays fabricated using two different methods, the three-dimensional printing custom trays and the conventional custom trays, and to prove the feasibility of the computer-aided design/computer-aided manufacturing (CAD/CAM) custom trays in clinical use from the perspective of clinical time cost. Twenty edentulous patients were recruited into this study, which was prospective, single blind, randomized self-control clinical trials. Two custom trays were fabricated for each participant. One of the custom trays was fabricated using functional suitable denture (FSD) system through CAD/CAM process, and the other was manually fabricated using conventional methods. Then the final impressions were taken using both the custom trays, followed by utilizing the final impression to fabricate complete dentures respectively. The technician production time of the custom trays and the clinical working time of taking the final impression was recorded. The average time spent on fabricating the three-dimensional printing custom trays using FSD system and fabricating the conventional custom trays manually were (28.6±2.9) min and (31.1±5.7) min, respectively. The average time spent on making the final impression with the three-dimensional printing custom trays using FSD system and the conventional custom trays fabricated manually were (23.4±11.5) min and (25.4±13.0) min, respectively. There was significant difference in the technician fabrication time and the clinical working time between the three-dimensional printing custom trays using FSD system and the conventional custom trays fabricated manually (P<0.05). The average time spent on fabricating three-dimensional printing custom trays using FSD system and making the final impression with the trays are less than those of the conventional custom trays fabricated manually, which reveals that the FSD three-dimensional printing custom trays is less time-consuming both in the clinical and laboratory process than the conventional custom trays. In addition, when we manufacture custom trays by three-dimensional printing method, there is no need to pour preliminary cast after taking the primary impression, therefore, it can save the impression material and model material. As to completing denture restoration, manufacturing custom trays using FSD system is worth being popularized.
TRAY MOUNTAIN ROADLESS AREA, GEORGIA.
Nelson, Arthur E.; Chatman, Mark L.
1984-01-01
A mineral survey indicates that the Tray Mountain Roadless Area, Georgia has little promise for the occurrence of metallic mineral resources. Rocks underlying the Tray Mountain Roadless Area are suitable for crushed rock or aggregate; however, other sources for these materials are available closer to present markets. There is a possibility for the occurrence of hydrocarbon resources underlying the area at great depth, but no hydrocarbon potential was identified. Detailed studies are needed to establish the presence or absence and mineral-resource potential of olivine, nickel, cobalt, and chrome in the two mafic-ultramafic bodies in the Hayesville thrust sheet. The cause of the lead anomaly in pan concentrate samples taken from the southwest part of the roadless area has not been established; the mineral residence and source of the anomaly remain to be determined.
STS-38 Pilot Culbertson removes film from an OV-104 middeck stowage locker
NASA Technical Reports Server (NTRS)
1990-01-01
STS-38 Pilot Frank L. Culbertson removes photographic film from stowage locker MF43E located on the middeck of Atlantis, Orbiter Vehicle (OV) 104. Additional items fastened to the forward lockers include a doll, meal tray assemblies, a SONY Walkman, a camera lens, and a Department of Air Force insignia (decal). The crew escape pole (CEP) extends over Culbertson's head and the open airlock hatch appears behind him.
STS-26 crew stowage review in Bldg 9A crew compartment trainer (CCT)
NASA Technical Reports Server (NTRS)
1988-01-01
STS-26 Discovery, Orbiter Vehicle (OV) 103, crewmembers rehearse for their upcoming mission in the crew compartment trainer (CCT) located in the JSC Mockup and Integration Laboratory Bldg 9A. Standing on the CCT middeck, Pilot Richard O. Covey hands a snack package to Mission Specialist (MS) John M. Lounge (back to the camera). Covey selected the snack from the meal tray assemblies (foodtrays) mounted on the forward middeck lockers.
Clinical evaluation of final impressions from three-dimensional printed custom trays.
Sun, Yuchun; Chen, Hu; Li, Hong; Deng, Kehui; Zhao, Tian; Wang, Yong; Zhou, Yongsheng
2017-11-02
This study aimed to evaluate the quality of the final impressions taken by three-dimensional printed custom trays for edentulous patients. Custom trays were designed with or without saddle-shaped tissue stops and fabricated by three-dimensional printing techniques. Manually made trays with photocurable materials were produced as controls. Both 3D printed custom trays and manually made ones were used to take impressions from edentulous patients. After 3D scanning of the final impression, the impression materials were removed, thus the underneath tray surfaces were able to be scanned, allowing the thickness of the impression materials to be measured. Final impressions obtained by pre-border-molded 3D printed trays were scanned as references, to which the flange extension deviations and morphology deviations of the impressions taken by both 3D printed trays and manually made ones were calculated. The results showed that (1) impressions from 3D printed custom trays had better thickness distribution than that of manually made ones; (2) impression morphology deviations in non-marginal area were neither statistic different between 3D printed trays and manually made trays, nor between trays with and without tissue stops; and (3) final impressions taken by custom trays without pre-border-molding were tended to have insufficient flange extensions.
Thermal control materials on EOIM-3
NASA Technical Reports Server (NTRS)
Finckenor, Miria M.; Linton, Roger C.; Kamenetzky, Rachel R.; Vaughn, Jason A.
1995-01-01
Thermal control paints, anodized aluminum, and beta cloth samples were flown on STS-46 as part of the Evaluation of Oxygen Interaction with Materials Experiment (EOIM-3). The thermal control paints flown on EOIM-3 include ceramic and polyurethane-based paints. Passively exposed samples are compared to actively heated samples and controlled exposure samples. Optical property measurements of absorptivity, emissivity, and spectrofluorescence are presented for each paint. Several variations of anodized aluminum, including chromic acid anodize, sulfuric acid anodize, and boric/sulfuric acid anodize were flown on the actively heated trays and the passive exposure trays. The post-flight optical properties are within tolerances for these materials. Also flown were two samples of yellow anodized aluminum. The yellow anodized aluminum samples darkened noticeably. Samples of aluminized and unaluminized beta cloth, a fiberglass woven mat impregnated with TFE Teflon, were flown with passive exposure to the space environment. Data from this part of the experiment is correlated to observations from LDEF and erosion of the Teflon thin film samples also flown on EOIM-3 and LDEF.
Effects of long-term exposure on LDEF fastener assemblies
NASA Astrophysics Data System (ADS)
Spear, Steve; Dursch, Harry
1992-09-01
This presentation summarizes the Systems Special Investigations Group (SIG) findings from testing and analysis of fastener assemblies used on the Long Duration Exposure Facility (LDEF) structure, the tray mounting clamps, and by the various experimenters. The LDEF deintegration team and several experimenters noted severe fastener damage and hardware removal difficulties during post-flight activities. The System SIG has investigated all reported instances, and in all cases examined to date, the difficulties were attributed to galling during installation or post-flight removal. To date, no evidence of coldwelding was found. Correct selection of materials and lubricants as well as proper mechanical procedures is essential to ensure successful on-orbit or post-flight installation and removal of hardware.
Effects of long-term exposure on LDEF fastener assemblies
NASA Technical Reports Server (NTRS)
Spear, Steve; Dursch, Harry
1992-01-01
This presentation summarizes the Systems Special Investigations Group (SIG) findings from testing and analysis of fastener assemblies used on the Long Duration Exposure Facility (LDEF) structure, the tray mounting clamps, and by the various experimenters. The LDEF deintegration team and several experimenters noted severe fastener damage and hardware removal difficulties during post-flight activities. The System SIG has investigated all reported instances, and in all cases examined to date, the difficulties were attributed to galling during installation or post-flight removal. To date, no evidence of coldwelding was found. Correct selection of materials and lubricants as well as proper mechanical procedures is essential to ensure successful on-orbit or post-flight installation and removal of hardware.
Chen, Hu; Yang, Xu; Chen, Litong; Wang, Yong; Sun, Yuchun
2016-01-01
The objective was to establish and evaluate a method for manufacture of custom trays for edentulous jaws using computer aided design and fused deposition modeling (FDM) technologies. A digital method for design the custom trays for edentulous jaws was established. The tissue surface data of ten standard mandibular edentulous plaster models, which was used to design the digital custom tray in a reverse engineering software, were obtained using a 3D scanner. The designed tray was printed by a 3D FDM printing device. Another ten hand-made custom trays were produced as control. The 3-dimentional surface data of models and custom trays was scanned to evaluate the accuracy of reserved impression space, while the difference between digitally made trays and hand-made trays were analyzed. The digitally made custom trays achieved a good matching with the mandibular model, showing higher accuracy than the hand-made ones. There was no significant difference of the reserved space between different models and its matched digitally made trays. With 3D scanning, CAD and FDM technology, an efficient method of custom tray production was established, which achieved a high reproducibility and accuracy. PMID:26763620
Yi, Myong-Hee; Shim, Joon-Sung; Lee, Keun-Woo; Chung, Moon-Kyu
2009-07-01
Use of custom tray and tray adhesive is clinically recommended for elastomeric impression material. However there is not clear mention of drying time of tray adhesive in achieving appropriate bonding strength of tray material and impression material. This study is to investigate an appropriate drying time of tray adhesives by evaluating tensile bonding strength between two types of polyvinylsiloxane impression materials and resin tray, according to various drying time intervals of tray adhesives, and with different manufacturing company combination of impression material and tray adhesive. Adhesives used in this study were Silfix (Dentsply Caulk, Milford, Del, USA) and VPS Tray Adhesive (3M ESPE, Seefeld, Germany) and impression materials were Aquasil Ultra (monophase regular set, Dentsply Caulk, Milford, Del, USA) and Imprint II Garant (regular body, 3M ESPE, Seefeld, Germany). They were used combinations from the same manufacture and exchanged combinations of the two. The drying time was designed to air dry, 5 minutes, 10 minutes, 15 minutes, 20 minutes, and 25 minutes. Total 240 of test specimens were prepared by auto-polymerizing tray material (Instant Tray Mix, Lang, Wheeling, Il, USA) with 10 specimens in each group. The specimens were placed in the Universal Testing machine (Instron, model 3366, Instron Corp, University avenue, Nowood, MA, USA) to perform the tensile test (cross head speed 5 mm/min). The statistically efficient drying time was evaluated through ANOVA and Scheffe test. All the tests were performed at 95% confidence level. The results revealed that at least 10 minutes is needed for Silfix-Aquasil, and 15 minutes for VPS Tray Adhesive-Imprint II, to attain an appropriate tensile bonding strength. VPS Tray Adhesive-Imprint II had a superior tensile bonding strength when compared to Silfix-Aquasil over 15 minutes. Silfix-Aquasil had a superior bonding strength to VPS Tray Adhesive-Aquasil, and VPS Tray Adhesive-Imprint II had a superior tensile bonding strength to Silfix-Imprint II at all drying periods. Significant increase in tensile bonding strength with Silfix-Aquasil and VPS Tray adhesive-Imprint II combination until 10 and 15 minutes respectively. Tray adhesive-impression material combination from the same company presented higher tensile bonding strength at all drying time intervals than when using tray adhesive-impression material of different manufactures.
NASA Technical Reports Server (NTRS)
Golden, Johnny L.; Bourassa, Roger J.; Dursch, Harry W.; Pippin, H. Gary
1995-01-01
The Energetic Oxygen Interaction with Materials 3 (EOIM-3) experiment was flown on the STS-46 mission, which was launched on 31 Jul. 1992 and returned 8 Aug. 1992. Boeing specimens were located on both the NASA Marshall Space Flight Center (MSFC) tray and the Ballistic Missile Defense Organization (BMDO) tray integrated by the Jet Propulsion Laboratory (JPL). The EOIM-3 pallet was mounted in the Space Shuttle payload bay near the aft bulkhead. During the mission, the atomic oxygen (AO) exposure levels of specimens in these passive sample trays was about 2.3 x 10(exp 20) atoms/sq cm. The specimens also received an estimated 22 equivalent sun hours of solar exposure. In addition, it appears that the EOIM-3 pallet was exposed to a silicone contamination source and many specimens had a thin layer of silicon based deposit on their surfaces after the flight. The specimens on the MSFC tray included seven solid film lubricants, a selection of butyl rubber (B612) and silicone (S383) o-rings, three indirect scatter surfaces, and Silver/Fluorinated Ethylene Propylene (Ag/FEP) and Chemglaze A276 specimens which had previously flown on trailing edge locations of the Long Duration Exposure Facility (LDEF). The specimens on the JPL tray included composites previously flown on LDEF and two indirect scattering surfaces.
An Automated, High-Throughput System for GISAXS and GIWAXS Measurements of Thin Films
NASA Astrophysics Data System (ADS)
Schaible, Eric; Jimenez, Jessica; Church, Matthew; Lim, Eunhee; Stewart, Polite; Hexemer, Alexander
Grazing incidence small-angle X-ray scattering (GISAXS) and grazing incidence wide-angle X-ray scattering (GIWAXS) are important techniques for characterizing thin films. In order to meet rapidly increasing demand, the SAXSWAXS beamline at the Advanced Light Source (beamline 7.3.3) has implemented a fully automated, high-throughput system to conduct SAXS, GISAXS and GIWAXS measurements. An automated robot arm transfers samples from a holding tray to a measurement stage. Intelligent software aligns each sample in turn, and measures each according to user-defined specifications. Users mail in trays of samples on individually barcoded pucks, and can download and view their data remotely. Data will be pipelined to the NERSC supercomputing facility, and will be available to users via a web portal that facilitates highly parallelized analysis.
Liu, Bin; Schaffner, Donald W
2007-11-01
Raw seed sprouts have been implicated in several food poisoning outbreaks in the past 10 years. The U.S. Food and Drug Administration recommends that sprout growers use interventions (such as testing of spent irrigation water) to control the presence of pathogens in the finished product. During the sprouting process, initially low concentrations of pathogen may increase, and contamination may spread within a batch of sprouting seeds. A model of pathogen growth as a function of time and distance from the contamination spot during the sprouting of alfalfa in trays has been developed with Enterobacter aerogenes. The probability of detecting contamination was assessed by logistic regression at various time points and distances by sampling from sprouts or irrigation water. Our results demonstrate that microbial populations and possibility of detection were greatly reduced at distances of > or = 20 cm from the point of contamination in a seed batch during tray sprouting; however, the probability of detecting microbial contamination at distances less than 10 cm from the point of inoculation was almost 100% at the end of the sprouting process. Our results also show that sampling irrigation water, especially large volumes of water, is highly effective at detecting contamination: by collecting 100 ml of irrigation water for membrane filtration, the probability of detection was increased by three to four times during the first 6 h of seed germination. Our findings have quantified the degree to which a small level of contamination will spread throughout a tray of sprouting alfalfa seeds and subsequently be detected by either sprout or irrigation water sampling.
STS-26 crew stowage review in Bldg 9A crew compartment trainer (CCT)
NASA Technical Reports Server (NTRS)
1988-01-01
STS-26 Discovery, Orbiter Vehicle (OV) 103, crewmembers rehearse for their upcoming mission in the crew compartment trainer (CCT) located in the JSC Mockup and Integration Laboratory Bldg 9A. Standing on the CCT middeck, the crewmembers have just selected a snack from the meal tray assembly (foodtray) mounted on the forward middeck lockers. Left to right are Mission Specialist (MS) John M. Lounge, Commander Frederick H. Hauck, and MS George D. Nelson.
Experimental study of cassava sun drying
DOE Office of Scientific and Technical Information (OSTI.GOV)
Njie, D.N.; Rumsey, T.R.
1997-03-01
Sun drying experiments were performed to compare drying of cassava chips in sheet-metal trays with drying on mesh wire trays. In the sheet-metal trays, there was air flow across the top of the bed chips, while the mesh wire trays permitted air to flow through the bed. Drying rate was faster and more uniform in the trays with through-flow air circulation. Higher temperatures were reached by chips in the sheet-metal trays than those in the mesh trays because of contact heating, but the drying rate was lower because of the reduced air flow.
Balouch, F; Jalalian, E; Nikkheslat, M; Ghavamian, R; Toopchi, Sh; Jallalian, F; Jalalian, S
2013-01-01
Statement of Problem: Various impression techniques have different effects on the accuracy of final cast dimensions. Meanwhile; there are some controversies about the best technique. Purpose: This study was performed to compare two kinds of implant impression methods (open tray and closed tray) on 15 degree angled implants. Materials and Method: In this experimental study, a steel model with 8 cm in diameter and 3 cm in height were produced with 3 holes devised inside to stabilize 3 implants. The central implant was straight and the other two implants were 15° angled. The two angled implants had 5 cm distance from each other and 3.5 cm from the central implant. Dental stone, high strength (type IV) was used for the main casts. Impression trays were filled with poly ether, and then the two impression techniques (open tray and closed tray) were compared. To evaluate positions of the implants, each cast was analyzed by CMM device in 3 dimensions (x,y,z). Differences in the measurements obtained from final casts and laboratory model were analyzed using t-Test. Results: The obtained results indicated that closed tray impression technique was significantly different in dimensional accuracy when compared with open tray method. Dimensional changes were 129 ± 37μ and 143.5 ± 43.67μ in closed tray and open tray, while coefficient of variation in closed- tray and open tray were reported to be 27.2% and 30.4%, respectively. Conclusion: Closed impression technique had less dimensional changes in comparison with open tray method, so this study suggests that closed tray impression technique is more accurate. PMID:24724130
Columbia, OV-102, forward middeck locker experiments and meal tray assemblies
1982-07-04
STS004-28-330 (27 June-4 July 1982) --- Thanks to a variety of juices and other food items, this array in the middeck area probably represents the most colorful area onboard the Earth-orbiting space shuttle Columbia. Most of the meal items have been carefully fastened to food trays and locker doors (or both). What has not been attached by conventional methods has been safely ?tucked? under something heavy (note jacket shoved into space occupied by one of Columbia?s experiments). The Monodisperse Latex Reflector (MLR), making its second flight on Columbia, is designed to test the feasibility of making large-size, monodisperse (same size), and polystyrene latex micro-spheres using the products of the STS-3 mission as seed particles. The latex spheres are used in calibration of scientific and industrial equipment and have potential medical and research applications. This frame was exposed with a 35mm camera. Onboard the space vehicle for seven days were astronauts Thomas K. Mattingly II and Henry W. Hartsfield Jr. Photo credit: NASA
Tracer Transport Along a Vertical Fault Located in Welded Tuffs
NASA Astrophysics Data System (ADS)
Salve, R.; Liu, H.; Hu, Q.
2002-12-01
A near-vertical fault that intercepts the fractured welled tuff formation in the underground Exploratory Studies Facility (ESF) at Yucca Mountain, Nevada, has provided a unique opportunity to evaluate important hydrological parameters associated with faults (e.g., flow velocity, matrix diffusion, fault-fracture-matrix interactions). Alcove 8, which intersects the fault is located in the cross drift of the ESF, has been excavated for liquid releases through this fault and a network of fractures. Located 25 m below Alcove 8 in the main drift of the ESF, Niche 3 which also intercepts the fault, serves as the site for monitoring the wetting front and for collecting seepage following liquid releases in Alcove 8. To investigate the importance of matrix diffusion and the extent of area subject to fracture-matrix interactions, we released a mix of conservative tracers (pentafluorobenzoic acid [PFBA] and lithium bromide [LiBr]) along the fault. The ceiling of Niche 3 was blanketed with an array of trays to capture seepage, and seepage rates were continuously monitored by a water collection system connected to the trays. Additionally, a water sampling device, the passive-discreet water sampler (PDWS), was connected to three of the collections trays in Niche 3 into which water was seeping. The PDWS, designed to isolate continuous seepage from each tray into discreet samples for chemical analysis, remained connected to the trays over a period of three months. During this time, all water that seeped into the three trays was captured sequentially into sampling bottles and analyzed for concentrations of PFBA and LiBr. Water released along the fault initially traveled the 25 m vertical distance over a period of 36 days (at a velocity ~0.7 m/day). The seepage recovered in Niche 3 was less than 10% of the injected water with significant spatial and temporal fluctuations in seepage rates. Along a fast flow path, the benzoic tracer (PFBA) and LiBr were first detected ~12 days after they were released into the fault. Along slower flow paths the tracers appeared ~ two weeks later, with PFBA preceding the LiB. The differing travel times of the two conservative tracers suggests the impact of matrix diffusion in the transport process. This work was supported by the Director, Office of Civilian Radioactive Waste Management, U.S. Department of Energy, through Memorandum Purchase Order EA9013MC5X between Bechtel SAIC Company, LLC, and the Ernest Orlando Lawrence Berkeley National Laboratory (Berkeley Lab). The support is provided to Berkeley Lab through the U.S. Department of Energy Contract No. DE-AC03-76SF00098.
Effects of long term space environment exposure on optical substrates and coatings (S0050-2)
NASA Technical Reports Server (NTRS)
Harvey, Keith; Mustico, Arthur; Vallimont, John
1993-01-01
Eastman Kodak Company included twelve substrate and coating samples on the Long Duration Exposure Facility (LDEF) structure. There were three Fused Silica and three Ultra Low Expansion (ULE) uncoated glass samples, two ULE samples with a high reflectance silver coating, two Fused Silica samples with an antireflectance coating, and two Fused silica samples with a solar rejection coating. A set of duplicate control samples was also manufactured and stored in a controlled environment for comparison purposes. Kodak's samples were included as a subset of the Georgia Institute of Technology tray, which was located on row 5-E, tray S0050-2. This placed the samples on the trailing edge of the structure, which protected them from the effects of atomic oxygen bombardment. An evaluation of the flight samples for effects from the 5 year mission showed that a contaminant was deposited on the samples, a micrometeoroid impact occurred on one of the samples, and the radiation darkening which was expected for the glass did not occur. The results are listed in more detail.
Chaffee, Bruce W; Lander, Michael J; Christen, Catherine; Redic, Kimberly A
2018-01-01
Purpose The primary aim was to determine if dispensing of cyclophosphamide tablets resulted in accumulated residue on pharmacy counting tools during a simulated outpatient dispensing process. Secondary objectives included determining if cyclophosphamide contamination exceeded a defined threshold level of 1 ng/cm 2 and if a larger number of prescriptions dispensed resulted in increased contamination. Methods Mock prescriptions of 40 cyclophosphamide 50 mg tablets were counted on clean trays in three scenarios using a simulated outpatient pharmacy after assaying five cleaned trays as controls. The three scenarios consisted of five simulated dispensings of one, three, or six prescriptions dispensed per scenario. Wipe samples of trays and spatulas were collected and assayed for all trays, including the five clean trays used as controls. Contamination was defined as an assayed cyclophosphamide level at or above 0.001 ng/cm 2 and levels above 1 ng/cm 2 were considered sufficient to cause risk of human uptake. Mean contamination for each scenario was calculated and compared using one-way analysis of variance. P-values of < 0.05 implied significance. Results Mean cyclophosphamide contamination on trays used to count one, three, and six cyclophosphamide prescriptions was 0.51 ± 0.10 (p=0.0003), 1.02 ± 0.10 (p < 0.0001), and 1.82 ± 0.10 ng/cm 2 (p < 0.0001), respectively. Control trays did not show detectable cyclophosphamide contamination. Increasing the number of prescriptions dispensed from 1 to 3, 1 to 6, and 3 to 6 counts increased contamination by 0.51 ± 0.15 (p = 0.0140), 1.31 + 0.15 (p < 0.0001), and 0.80 ± 0.15 ng/cm 2 (p = 0.0004), respectively. Conclusion Dispensing one or more prescriptions of 40 cyclophosphamide 50 mg tablets contaminates pharmacy counting tools, and an increased number of prescriptions dispensed correlates with increased level of contamination. Counting out three or more prescriptions leads to trays having contamination that surpasses the threshold at which worker exposure may be increased. Pharmacies should consider devoting a separate tray to cyclophosphamide tablets, as cross-contamination could occur with other drugs and the efficacy of decontamination methods is unclear. Employee exposure could be minimized with the use of personal protective equipment, environmental controls, and cleaning trays between uses. Future investigation should assess the extent of drug powder dispersion, the effects of various cleaning methods, and the potential extent of contamination with different oral cytotoxic drugs.
View of food tray to be used in Skylab program
NASA Technical Reports Server (NTRS)
1972-01-01
A close-up view of a food tray which is scheduled to be used in the Skylab program. Several packages of space food lie beside the tray. The food in the tray is ready to eat. Out of tray, starting from bottom left: grape drink, beef pot roast, chicken and rice, beef sandwiches and sugar cookie cubes, In tray, from back left: orange drink, strawberries, asparagus, prime rib, dinner roll and butterscotch pudding in the center.
Distillation tray structural parameter study: Phase 1
NASA Technical Reports Server (NTRS)
Winter, J. Ronald
1991-01-01
The purpose here is to identify the structural parameters (plate thickness, liquid level, beam size, number of beams, tray diameter, etc.) that affect the structural integrity of distillation trays in distillation columns. Once the sensitivity of the trays' dynamic response to these parameters has been established, the designer will be able to use this information to prepare more accurate specifications for the construction of new trays. Information is given on both static and dynamic analysis, modal response, and tray failure details.
STS-35 crewmembers eat meal on the middeck of Columbia, OV-102
NASA Technical Reports Server (NTRS)
1990-01-01
Enjoying a meal on the middeck of Columbia, Orbiter Vehicle (OV) 102, are STS-35 Mission Specialist (MS) Robert A.R. Parker (foreground), Payload Specialist Ronald A. Parise (center), and Commander Vance D. Brand. Parker spoons up bite from his food container as Parise lets a spoonful freefloat into his open mouth and Brand balances his meal tray assembly. The forward lockers, the shuttle treadmill, and the starboard side sleep station are seen in the view.
STS-7 crewmembers during meal preparation on middeck
NASA Technical Reports Server (NTRS)
1983-01-01
On middeck, Mission Specialist (MS) Thagard and MS Ride select food containers from forward modular locker single tray assembly (ASSY) and prepare containers for heating while Pilot Hauck (with mustache) adjusts SONY Walkman and MS Fabian opens containers. Carry-on food warmer appears overhead and control panel ML86B and Continuous Flow Electrophoresis System (CFES) fluid systems module appear on port side wall. Hauck wears a TFNG t-shirt as a tribute to the 1978 class of NASA astronauts.
Reddy, Nagam Raja; Reddy, Jakranpally Sathya; Padmaja, Bramha Josyula Indira; Reddy, Budigi Madan Mohan; Sunil, Motupalli; Reddy, Bommireddy Tejeswar
2016-01-01
To evaluate the accuracy of dies made from dual arch impressions using different sectional dual arch trays, combinations of elastomeric impression materials, and the sequence of pour of dies. The dual arch impression materials were grouped into three groups depending on the combination of impression materials used and each group is subdivided into four subgroups. A sample size of 8 in each subgroup yielding a total 96 impressions will be made into three groups of 32 each (Group I, II, and III). Group I constitute impressions made using monophase (M) impression material, Group II constitute impressions made using combination of heavy body and light body (HL), and Group III constitute impressions made using combination of putty and light body (PL). Dies obtained were evaluated with a travelling microscope to measure the buccolingual width of the tooth at the margin by using the sharp corners of the notches as reference points. Descriptive analysis namely mean and standard deviation, one-way analysis of variance test. The results obtained in this study indicate that though not statistically significant, the metal dual arch trays performed better when compared to the plastic trays in reproducing die dimensions. From the results obtained, dies poured from combination of heavy body and light body impressions using plastic or metal dual arch trays showed least variation in bucco-lingual dimension from master model.
Reddy, Nagam Raja; Reddy, Jakranpally Sathya; Padmaja, Bramha Josyula Indira; Reddy, Budigi Madan Mohan; Sunil, Motupalli; Reddy, Bommireddy Tejeswar
2016-01-01
Aims: To evaluate the accuracy of dies made from dual arch impressions using different sectional dual arch trays, combinations of elastomeric impression materials, and the sequence of pour of dies. Subjects and Methods: The dual arch impression materials were grouped into three groups depending on the combination of impression materials used and each group is subdivided into four subgroups. A sample size of 8 in each subgroup yielding a total 96 impressions will be made into three groups of 32 each (Group I, II, and III). Group I constitute impressions made using monophase (M) impression material, Group II constitute impressions made using combination of heavy body and light body (HL), and Group III constitute impressions made using combination of putty and light body (PL). Dies obtained were evaluated with a travelling microscope to measure the buccolingual width of the tooth at the margin by using the sharp corners of the notches as reference points. Statistical Analysis Used: Descriptive analysis namely mean and standard deviation, one-way analysis of variance test. Results: The results obtained in this study indicate that though not statistically significant, the metal dual arch trays performed better when compared to the plastic trays in reproducing die dimensions. Conclusions: From the results obtained, dies poured from combination of heavy body and light body impressions using plastic or metal dual arch trays showed least variation in bucco-lingual dimension from master model. PMID:27141172
Implementation of a robotic flexible assembly system
NASA Technical Reports Server (NTRS)
Benton, Ronald C.
1987-01-01
As part of the Intelligent Task Automation program, a team developed enabling technologies for programmable, sensory controlled manipulation in unstructured environments. These technologies include 2-D/3-D vision sensing and understanding, force sensing and high speed force control, 2.5-D vision alignment and control, and multiple processor architectures. The subsequent design of a flexible, programmable, sensor controlled robotic assembly system for small electromechanical devices is described using these technologies and ongoing implementation and integration efforts. Using vision, the system picks parts dumped randomly in a tray. Using vision and force control, it performs high speed part mating, in-process monitoring/verification of expected results and autonomous recovery from some errors. It is programmed off line with semiautomatic action planning.
Nishigawa, G; Sato, T; Suenaga, K; Minagi, S
1998-02-01
Tray adhesive, which is used for the adhesion of elastomer rubber impression materials to a custom resin tray, lowers the retention of the impression materials to the impression modeling plastics, as some ingredients of tray adhesive make the impression modeling plastic soft and tacky. The efficacy of tray adhesive, which is used for the adhesion of elastomer rubber impression materials to a custom resin tray, on the adhesion between elastomer rubber impression material and impression modeling plastic was investigated. Four silicone rubber impression materials (two addition reaction types and two condensation reaction types), two polysulfide rubber impression materials, and one impression modeling plastic were used in this study. Tensile strength between elastomer rubber impression material and impression modeling plastic with or without the application of tray adhesive was evaluated. Although tray adhesives for both addition reaction type and both condensation reaction type of silicone impression materials and one tray adhesive for polysulfide rubber impression material increased the tensile strength between the impression material and impression modeling plastic, one tray adhesive for polysulfide rubber impression material decreased the tensile strength when sufficient drying time was not applied.
A Proposed Combat Food Service System Concept for the Army in 1990
1980-01-01
Tray (T) 1 Froz (F) Swedish Meatballs 1 Tray (T) - 1 Froz (F) Ham - 3 Canned (B) 1 Froz (F) Roast Pork/Gravy 1 Tray (T) - - Stuffed Pork Slices...Froz (F) Beef Stew 2 Tray (T) 2 Dehy (D) 2 Froz (F) Lasagna 1 Tray (T) 2 Dry/Dehy (D) 2 Dry/Froz (F) Spaghetti/ Meatballs 1 Tray (T) 2 Dry/Dehy (D) 1...Breakfast Maat Entrae — B Canadian Bacon Bacon Ham Slices Sausage Mon Meat Entree — B Eggs Cheese Omelet French Toast Pancakes Starch - B
John-Baptiste, A.; Sowerby, L.J.; Chin, C.J.; Martin, J.; Rotenberg, B.W.
2016-01-01
Background: When prearranged standard surgical trays contain instruments that are repeatedly unused, the redundancy can result in unnecessary health care costs. Our objective was to estimate potential savings by performing an economic evaluation comparing the cost of surgical trays with redundant instruments with surgical trays with reduced instruments ("reduced trays"). Methods: We performed a cost-analysis from the hospital perspective over a 1-year period. Using a mathematical model, we compared the direct costs of trays containing redundant instruments to reduced trays for 5 otolaryngology procedures. We incorporated data from several sources including local hospital data on surgical volume, the number of instruments on redundant and reduced trays, wages of personnel and time required to pack instruments. From the literature, we incorporated instrument depreciation costs and the time required to decontaminate an instrument. We performed 1-way sensitivity analyses on all variables, including surgical volume. Costs were estimated in 2013 Canadian dollars. Results: The cost of redundant trays was $21 806 and the cost of reduced trays was $8803, for a 1-year cost saving of $13 003. In sensitivity analyses, cost savings ranged from $3262 to $21 395, based on the surgical volume at the institution. Variation in surgical volume resulted in a wider range of estimates, with a minimum of $3253 for low-volume to a maximum of $52 012 for high-volume institutions. Interpretation: Our study suggests moderate savings may be achieved by reducing surgical tray redundancy and, if applied to other surgical specialties, may result in savings to Canadian health care systems. PMID:27975045
John-Baptiste, A; Sowerby, L J; Chin, C J; Martin, J; Rotenberg, B W
2016-01-01
When prearranged standard surgical trays contain instruments that are repeatedly unused, the redundancy can result in unnecessary health care costs. Our objective was to estimate potential savings by performing an economic evaluation comparing the cost of surgical trays with redundant instruments with surgical trays with reduced instruments ("reduced trays"). We performed a cost-analysis from the hospital perspective over a 1-year period. Using a mathematical model, we compared the direct costs of trays containing redundant instruments to reduced trays for 5 otolaryngology procedures. We incorporated data from several sources including local hospital data on surgical volume, the number of instruments on redundant and reduced trays, wages of personnel and time required to pack instruments. From the literature, we incorporated instrument depreciation costs and the time required to decontaminate an instrument. We performed 1-way sensitivity analyses on all variables, including surgical volume. Costs were estimated in 2013 Canadian dollars. The cost of redundant trays was $21 806 and the cost of reduced trays was $8803, for a 1-year cost saving of $13 003. In sensitivity analyses, cost savings ranged from $3262 to $21 395, based on the surgical volume at the institution. Variation in surgical volume resulted in a wider range of estimates, with a minimum of $3253 for low-volume to a maximum of $52 012 for high-volume institutions. Our study suggests moderate savings may be achieved by reducing surgical tray redundancy and, if applied to other surgical specialties, may result in savings to Canadian health care systems.
Atmospheric Delta14C Record from Wellington (1954-1993)
Manning, M R. [National Institute of Water and Atmospheric Research, Ltd., Lower Hutt, New Zealand; Melhuish, W. H. [National Institute of Water and Atmospheric Research, Ltd., Lower Hutt, New Zealand
1994-09-01
Trays containing ~2 L of 5 normal NaOH carbonate-free solution are typically exposed for intervals of 1-2 weeks, and the atmospheric CO2 absorbed during that time is recovered by acid evolution. Considerable fractionation occurs during absorption into the NaOH solution, and the standard fractionation correction (Stuiver and Polach 1977) is used to determine a δ 14C value corrected to δ 13C = -25 per mil. Some samples reported here were taken using BaOH solution or with extended tray exposure times. These variations in procedure do not appear to affect the results (Manning et al. 1990). A few early measurements were made by bubbling air through columns of NaOH for several hours. These samples have higher δ 13C values. Greater details on the sampling methods are provided in Manning et al. (1990) and Rafter and Fergusson (1959).
LDEF active optical system components experiment
NASA Technical Reports Server (NTRS)
Blue, M. D.
1992-01-01
A preliminary report on the Active Optical System Components Experiment is presented. This experiment contained 136 components in a six inch deep tray including lasers, infrared detectors and arrays, ultraviolet light detectors, light-emitting diodes, a light modulator, flash lamps, optical filters, glasses, and samples of surface finishes. Thermal, mechanical, and structural considerations leading to the design of the tray hardware are discussed. In general, changes in the retested component characteristics appear as much related to the passage of time as to the effects of the space environment, but organic materials, multilayer optical interference filters, and extreme-infrared reflectivity of black paints show unexpected changes.
Aeroelastic Response and Protection of Space Shuttle External Tank Cable Trays
NASA Technical Reports Server (NTRS)
Edwards, John W.; Keller, Donald F.; Schuster, David M.; Piatak, David J.; Rausch, Russ D.; Bartels, Robert E.; Ivanco, Thomas G.; Cole, Stanley R.; Spain, Charles V.
2005-01-01
Sections of the Space Shuttle External Tank Liquid Oxygen (LO2) and Liquid Hydrogen (LH2) cable trays are shielded from potentially damaging airloads with foam Protuberance Aerodynamic Load (PAL) Ramps. Flight standard design LO2 and LH2 cable tray sections were tested with and without PAL Ramp models in the United States Air Force Arnold Engineering Development Center s (AEDC) 16T transonic wind tunnel to obtain experimental data on the aeroelastic stability and response characteristics of the trays and as part of the larger effort to determine whether the PAL ramps can be safely modified or removed. Computational Fluid Dynamic simulations of the full-stack shuttle launch configuration were used to investigate the flow characeristics around and under the cable trays without the protective PAL ramps and to define maximum crossflow Mach numbers and dynamic pressures experienced during launch. These crossflow conditions were used to establish wind tunnel test conditions which also included conservative margins. For all of the conditions and configurations tested, no aeroelastic instabilities or unacceptable dynamic response levels were encountered and no visible structural damage was experienced by any of the tested cable tray sections. Based upon this aeroelastic characterization test, three potentially acceptable alternatives are available for the LO2 cable tray PAL Ramps: Mini-Ramps, Tray Fences, or No Ramps. All configurations were tested to maximum conditions, except the LH2 trays at -15 deg. crossflow angle. This exception is the only caveat preventing the proposal of acceptable alternative configurations for the LH2 trays as well. Structural assessment of all tray loads and tray response measurements from launches following the Shuttle Return To Flight with the existing PAL Ramps will determine the acceptability of these PAL Ramp alternatives.
Humphries, Laura S; Shenaq, Deana S; Teven, Chad M; Park, Julie E; Song, David H
2018-01-01
We hypothesize that reusable, on-site specialty instrument trays available to plastic surgery residents in the emergency department (ED) for bedside procedures are more cost-effective than disposable on-site and remote re-usable operating room (OR) instruments at our institution. We completed a cost-effectiveness analysis comparing the use of disposable on-site kits and remote OR trays to a hypothetical, custom, reusable tray for ED procedures completed by PRS residents. Material costs of existing OR trays were used to estimate the purchasing and use-cost of a custom on-site tray for the same procedures. Cost of per procedure 'consult time' was estimated using procedure and resident salary. Sixteen bedside procedures were completed over a 4.5 month period. A mean of 2.14 disposable kits were used per-procedure. Mean consultation time was 1.66 hours. Procedures that used OR trays took 3 times as long as procedures that used on-site kits (4 vs. 1.1 hours). Necessary, additional instruments were unavailable for 75% of procedures. Mean cost of using disposable kits and OR trays was $115.03/procedure versus an estimated $26.67/procedure cost of using a custom tray, yielding $88.36/procedure cost-savings. Purchase of a single custom tray ($1,421.55) would be redeemed after 2.3 weeks at 1 procedure/day. Purchasing 4 trays has projected annual cost-savings of $26,565.20. The purchase of specialized procedure trays will yield valuable time and cost-savings while providing quality patient care. Improving time efficiency will help achieve the Accreditation Council of Graduate Medical Education (ACGME) goals of maintaining resident well-being and developing quality improvement competency.
Haldimann, M.; Alt, A.; Blanc, A.; Brunner, K.; Sager, F.; Dudler, V.
2013-01-01
Migration experiments with small sheets cut out from ovenable PET trays were performed in two-sided contact with 3% acetic acid as food simulant at various temperatures. The fraction of diffusible antimony (Sb) was estimated to be 62% in the PET sample under study. Apparent diffusion coefficients of Sb in PET trays were determined experimentally. Measurement of migration between 20 and 150°C yielded a linear Arrhenius plot over a wide temperature range from which the activation energy (Ea) of 188 ± 36 kJ mol−1 and the pre-exponential factor (D0) of 3.6 × 1014 cm2s−1 were determined for diffusing Sb species. Ea was similar to previously reported values for PET bottles obtained with a different experimental approach. Ea and D0 were applied as model parameters in migration modelling software for predicting the Sb transfer in real food. Ready meals intended for preparation in a baking oven were heated in the PET trays under study and the actual Sb migration into the food phase was measured by isotope dilution ICP-MS. It was shown that the predictive modelling reproduces correctly experimental data. PMID:23286325
Haldimann, M; Alt, A; Blanc, A; Brunner, K; Sager, F; Dudler, V
2013-01-01
Migration experiments with small sheets cut out from ovenable PET trays were performed in two-sided contact with 3% acetic acid as food simulant at various temperatures. The fraction of diffusible antimony (Sb) was estimated to be 62% in the PET sample under study. Apparent diffusion coefficients of Sb in PET trays were determined experimentally. Measurement of migration between 20 and 150°C yielded a linear Arrhenius plot over a wide temperature range from which the activation energy (E(a)) of 188 ± 36 kJ mol(-1) and the pre-exponential factor (D(0)) of 3.6 × 10(14) cm(2) s(-1) were determined for diffusing Sb species. E (a) was similar to previously reported values for PET bottles obtained with a different experimental approach. E (a) and D (0) were applied as model parameters in migration modelling software for predicting the Sb transfer in real food. Ready meals intended for preparation in a baking oven were heated in the PET trays under study and the actual Sb migration into the food phase was measured by isotope dilution ICP-MS. It was shown that the predictive modelling reproduces correctly experimental data.
Dissipation of fragrance materials in sludge-amended soils.
DiFrancesco, Angela M; Chiu, Pei C; Standley, Laurel J; Allen, Herbert E; Salvito, Daniel T
2004-01-01
A possible removal mechanism for fragrance materials (FMs) in wastewater is adsorption to sludge, and sludge application to land may be a route through which FMs are released to the soil environment. However, little is known about the concentrations and fate of FMs in soil receiving sludge application. This study was conducted to better understand the dissipation of FMs in sludge-amended soils. We first determined the spiking and extraction efficiencies for 22 FMs in soil and leachate samples. Nine FMs were detected in digested sludges from two wastewater treatment plants in Delaware using these methods. We conducted a 1-year die-away experiment which involved four different soils amended with sludge, with and without spiking of the 22 FMs. The initial dissipation of FMs in all spiked trays was rapid, and only seven FMs remained at concentrations above the quantification limits after 3 months: AHTN, HHCB, musk ketone, musk xylene, acetyl cedrene, OTNE, and DPMI. After 1 year, the only FMs remaining in all spiked trays were musk ketone and AHTN. DPMI was the only FM that leached significantly from the spiked trays, and no FMs were detected in leachate from any unspiked tray. While soil organic matter content affected the dissipation rate in general, different mechanisms (volatilization, transformation, leaching) appeared to be important for different FMs.
SKYLAB (SL) - MANUFACTURING (FOOD)
1971-12-30
S72-15409 (1972) --- A close-up view of a food tray which is scheduled to be used in the Skylab program. Several packages of space food lie beside the tray. The food in the tray is ready to eat. Out of tray, starting from bottom left: grape drink, beef pot roast, chicken and rice, beef sandwiches and sugar cookie cubes. In tray, from back left: orange drink, strawberries, asparagus, prime rib, dinner roll and butterscotch pudding in the center. Photo credit: NASA
Influence of tray rigidity and impression technique on accuracy of polyvinyl siloxane impressions.
Hoyos, Alex; Soderholm, Karl-Johan
2011-01-01
The aim of this study was to determine how tray rigidity and impression technique affect the accuracy of polyvinyl siloxane impressions. Disposable plastic trays and metallic Rim-Lock trays were used in combination with a heavy/light body technique or with two different putty-wash techniques. For each technique-tray combination, 10 impressions were made of a master cast with two steel abutments representing the mandibular right first premolar and second molar, between which a steel rod was placed at the ridge level. Each steel abutment had five marks, while the steel rod in between the two abutments had only one mark, which served as a reference point. With a universal measuring microscope, the x-, y-, and z-coordinates were recorded for each mark on the master cast and impressions. The distances between the different marks and the reference point on the impressions were calculated and compared with those of the master cast. All techniques used with the plastic trays had distances that were significantly different from the master cast (P < .05), while for the metal trays, it was only the heavy/light body technique that resulted in distances that were significantly different from the master cast (P < .05). Plastic trays produced less accurate impressions than metal trays. When metal trays were used, putty-based impressions were dimensionally better than heavy/light body impressions.
21 CFR 868.6100 - Anesthetic cabinet, table, or tray.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthetic cabinet, table, or tray. 868.6100... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6100 Anesthetic cabinet, table, or tray. (a) Identification. An anesthetic cabinet, table, or tray is a device intended to store...
21 CFR 868.6100 - Anesthetic cabinet, table, or tray.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Anesthetic cabinet, table, or tray. 868.6100... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6100 Anesthetic cabinet, table, or tray. (a) Identification. An anesthetic cabinet, table, or tray is a device intended to store...
21 CFR 868.6100 - Anesthetic cabinet, table, or tray.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Anesthetic cabinet, table, or tray. 868.6100... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6100 Anesthetic cabinet, table, or tray. (a) Identification. An anesthetic cabinet, table, or tray is a device intended to store...
21 CFR 868.6100 - Anesthetic cabinet, table, or tray.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Anesthetic cabinet, table, or tray. 868.6100... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6100 Anesthetic cabinet, table, or tray. (a) Identification. An anesthetic cabinet, table, or tray is a device intended to store...
21 CFR 868.6100 - Anesthetic cabinet, table, or tray.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Anesthetic cabinet, table, or tray. 868.6100... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6100 Anesthetic cabinet, table, or tray. (a) Identification. An anesthetic cabinet, table, or tray is a device intended to store...
The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap
Saboury, Abolfazl; Neshandar Asli, Hamid; Dalili Kajan, Zahra
2017-01-01
Statement of the Problem: Precision of the impression taken from implant positions significantly determines accurate fit of implant-supported prostheses. An imprecise impression may produce prosthesis misfit. Purpose: This study aimed to evaluate the accuracy of four impression-making techniques for angulated implants by stereomicroscope through measuring the vertical marginal gaps between the cemented metal framework and the implant analog. Materials and Method: A definitive cast with two 15° mesially angulated implants served as the standard reference for making all the impressions and later for accuracy evaluation. Four groups of five samples were evaluated: (1) closed-tray snap-fit transfer, (2) open-tray nonsplinted impression coping, (3) metal splinted impression coping, and (4) fabricated acrylic resin transfer cap. A gold-palladium framework was fabricated over the angulated implant abutments, the fit of which was used as reference. The gaps between the metal framework and the implant analogs were measured in sample groups. Corresponding means for each technique and the definitive cast were compared by using ANOVA and post hoc tests. Results: The mean marginal gap was 38.16±0µm in definitive cast, 89±19.74µm in group 1, 78.66±20.63µm in group 2, 54.16±24.29µm in group 3, and 55.83±18.30µm in group 4. ANOVA revealed significant differences between the definitive cast and groups 1 and 2, but not with groups 3 and 4 (p< 0.05). Conclusion: Vertical gap measurements showed that metal splinted impression coping and fabricated acrylic resin transfer cap techniques produced quite more accurate impressions than closed-tray snap-fit transfer and open-tray nonsplinted impression coping techniques do. The fabricated acrylic resin transfer cap technique seems to be a reliable impression-making method. PMID:29201973
1994-07-31
everything that is received in ESD protective packaging materials treated as ESDS? YES/NO 40.1.13 Is the use of personal hygiene products , food, drinks...Does the training explain why food, drinks, smoking, personal hygiene products or common plastics are not to be used in ESD protective work areas? YES...trays? YES/NO 40.5.13 Are drinking, eating, smoking, the use of personal hygiene products and common plastics prohibited in the ESD protected work area
STS-28 Columbia, OV-102, MS Brown juggles food containers on middeck
NASA Technical Reports Server (NTRS)
1989-01-01
At open middeck stowage locker MF14G single tray assembly, Mission Specialist (MS) Mark N. Brown removes food containers during meal preparation activities. Fellow crewmember MS James C. Adamson looks on as food and beverage containers, cans, and bags freefloat in front of Brown and above the open locker. At Brown's left along the port side wall are the side hatch, galley, and control panel ML86B. Brown is wearing a t-shirt and light blue constant wear garment with notepad strapped above his knee.
Abbott prism: a multichannel heterogeneous chemiluminescence immunoassay analyzer.
Khalil, O S; Zurek, T F; Tryba, J; Hanna, C F; Hollar, R; Pepe, C; Genger, K; Brentz, C; Murphy, B; Abunimeh, N
1991-09-01
We describe a multichannel heterogeneous immunoassay analyzer in which a sample is split between disposable reaction trays in a group of linear tracks. The system's pipettor uses noninvasive sensing of the sample volume and disposable pipet tips. Each assay track has (a) a conveyor belt for moving reaction trays to predetermined functional stations, (b) temperature-controlled tunnels, (c) noncontact transfer of the reaction mixture between incubation and detection wells, and (d) single-photon counting to detect a chemiluminescence (CL) signal from the captured immunochemical product. A novel disposable reaction tray, with separate reaction and detection wells and self-contained fluid removal, is used in conjunction with the transfer device on the track to produce a carryover-free system. The linear immunoassay track has nine predetermined positions for performing individual assay steps. Assay step sequence and timing is selected by changing the location of the assay modules between these predetermined positions. The assay methodology, a combination of microparticle capture and direct detection of a CL signal on a porous matrix, offers excellent sensitivity, specificity, and ease of automation. Immunoassay configurations have been tested for hepatitis B surface antigen and for antibodies to hepatitis B core antigen, hepatitis C virus, human immunodeficiency virus I and II, and human T-cell leukemia virus I and II.
Food Recognition: A New Dataset, Experiments, and Results.
Ciocca, Gianluigi; Napoletano, Paolo; Schettini, Raimondo
2017-05-01
We propose a new dataset for the evaluation of food recognition algorithms that can be used in dietary monitoring applications. Each image depicts a real canteen tray with dishes and foods arranged in different ways. Each tray contains multiple instances of food classes. The dataset contains 1027 canteen trays for a total of 3616 food instances belonging to 73 food classes. The food on the tray images has been manually segmented using carefully drawn polygonal boundaries. We have benchmarked the dataset by designing an automatic tray analysis pipeline that takes a tray image as input, finds the regions of interest, and predicts for each region the corresponding food class. We have experimented with three different classification strategies using also several visual descriptors. We achieve about 79% of food and tray recognition accuracy using convolutional-neural-networks-based features. The dataset, as well as the benchmark framework, are available to the research community.
Martin, J Ryan; Watts, Chad D; Levy, Daniel L; Miner, Todd M; Springer, Bryan D; Kim, Raymond H
2017-01-01
Stress shielding is an uncommon complication associated with primary total knee arthroplasty. Patients are frequently identified radiographically with minimal clinical symptoms. Very few studies have evaluated risk factors for postoperative medial tibial bone loss. We hypothesized that thicker cobalt-chromium tibial trays are associated with increased bone loss. We performed a retrospective review of 100 posterior stabilized, fixed-bearing total knee arthroplasty where 50 patients had a 4-mm-thick tibial tray (thick tray cohort) and 50 patients had a 2.7-mm-thick tibial tray (thin tray cohort). A clinical evaluation and a radiographic assessment of medial tibial bone loss were performed on both cohorts at a minimum of 2 years postoperatively. Mean medial tibial bone loss was significantly higher in the thick tray cohort (1.07 vs 0.16 mm; P = .0001). In addition, there were significantly more patients with medial tibial bone loss in the thick tray group compared with the thin tray group (44% vs 10%, P = .0002). Despite these differences, there were no statistically significant differences in range of motion, knee society score, complications, or revision surgeries performed. A thicker cobalt-chromium tray was associated with significantly more medial tibial bone loss. Despite these radiographic findings, we found no discernable differences in clinical outcomes in our patient cohort. Further study and longer follow-up are needed to understand the effects and clinical significance of medial tibial bone loss. Copyright © 2016 Elsevier Inc. All rights reserved.
Cost Savings of Standardization of Thoracic Surgical Instruments: The Process of Lean.
Cichos, Kyle H; Linsky, Paul L; Wei, Benjamin; Minnich, Douglas J; Cerfolio, Robert J
2017-12-01
Our objective is to show the effect that standardization of surgical trays has on the number of instruments sterilized and on cost. We reviewed our most commonly used surgical trays with the 3 general thoracic surgeons in our division and agreed upon the least number of surgical instruments needed for mediastinoscopy, video-assisted thoracoscopic surgery, robotic thoracic surgery, and thoracotomy. We removed 59 of 79 instruments (75%) from the mediastinoscopy tray, 45 of 73 (62%) from the video-assisted thoracoscopic surgery tray, 51 of 84 (61%) from the robotic tray, and 50 of 113 (44%) from the thoracotomy tray. From January 2016 to December 2016, the estimated savings by procedure were video-assisted thoracoscopic surgery (n = 398) $21,890, robotic tray (n = 231) $19,400, thoracotomy (n = 163) $15,648, and mediastinoscopy (n = 162) $12,474. Estimated total savings were $69,412. The weight of the trays was reduced 70%, and the nonsteamed sterilization rate (opened trays that needed to be reprocessed) decreased from 2% to 0%. None of the surgeons requested any of the removed instruments. Standardization of thoracic surgical trays is possible despite having multiple thoracic surgeons. This process of lean (the removal of nonvalue steps or equipment) reduces the number of instruments cleaned and carried and reduces cost. It may also reduce the incidence of "wet loads" that require the resterilization of instruments. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Winters, Gregory S.; Retherford, Kurt D.; Davis, Michael W.; Escobedo, Stephen M.; Bassett, Eric C.; Patrick, Edward L.; Nagengast, Maggie E.; Fairbanks, Matthew H.; Miles, Paul F.; Parker, Joel W.; Gladstone, G. Randall; Slater, David C.; Stern, S. Alan
2012-10-01
We designed and assembled a highly capable UV reflectometer chamber and data acquisition system to provide bidirectional scattering data of various surfaces and materials. This chamber was initially conceived to create laboratory-based UV reflectance measurements of water frost on lunar soil/regolith simulants, to support interpretation of UV reflectance data from the Lyman Alpha Mapping Project ("LAMP") instrument on-board the NASA Lunar Reconnaissance Orbiter spacecraft. A deuterium lamp illuminates surfaces and materials at a fixed 45° incident beam angle over the 115 to 200 nm range via a monochromator, while a photomultiplier tube detector is scanned to cover emission angles -85° to +85° (with a gap from -60° to -30°, due to the detector blocking the incident beam). Liquid nitrogen cools the material/sample mount when desired. The chamber can be configured to test a wide range of samples and materials using sample trays and holders. Test surfaces to date include aluminum mirrors, water ice, reflectance standards, and frozen mixtures of water and lunar soil/regolith stimulant. Future UV measurements planned include Apollo lunar samples, meteorite samples, other ices, minerals, and optical surfaces. Since this chamber may well be able to provide useful research data for groups outside Southwest Research Institute, we plan to take requests from and collaborate with others in the UV and surface reflection research community.
Kawasaki, Yui; Sakai, Masashi; Nishimura, Kazuhiro; Fujiwara, Keiko; Fujisaki, Kahori; Shimpo, Misa; Akamatsu, Rie
2016-12-01
The accuracy of the visual estimation method is unknown, even though it is commonly used in hospitals to measure the dietary intake of patients. We aimed to compare the difference in the validity of visual estimation according to the raters' job categories and tray divisions, and to demonstrate associations between meal characteristics and validity of visual estimation in a usual clinical setting in a community hospital. We collected patients' dietary intake data in usual clinical settings for each tray in 3 ways: visual estimation by nursing assistants, visual estimation by dietitians, and weighing by researchers (reference method). Dietitians estimated the dietary intake using 2 divisions, namely, whole tray and food items. Then we compared the weights and visual estimation data to evaluate the validity of the visual estimation method. Mean nutrient consumption of target trays was significantly different when using the visual estimation of target trays than when using the weighed method (visual estimation by nursing assistants [589 ± 168 kcal, 24.3 ± 7.0 g/tray, p < 0.01], dietitians' whole trays [561 ± 171 kcal, 23.0 ± 6.9 g/tray, p < 0.05], food items [562 ± 171 kcal/tray, p < 0.05], and dietitians' food items [23.4 ± 7.3 g/tray, p = 0.63]). Spearman's correlations for both methods were very high for energy (ρ = 0.91-0.98, p < 0.01) and protein intakes (ρ = 0.88-0.96, p < 0.01), respectively. The limits of agreement in the Bland-Altman plot for both dietary intake categories were -121 kcal to 147 kcal/tray and -6.4 g to 7.0 g/tray (nursing assistants, whole division), -122 kcal-106 kcal/tray and -6.7 g to 5.5 g/tray (dietitians, whole divisions), and -82 kcal to 66 kcal/tray and -4.3 g to 3.9 g/tray (dietitians, food items divisions). High intake rate of grains was significantly associated with decreased odds of a difference between two methods based on the nursing assistant's whole tray evaluation (odds ratio [OR]: 0.85; 95% confidence interval [CI]: 0.76-0.94) and the dietitians' whole tray (OR: 0.80; 95% CI: 0.72-0.89) and food items evaluations (OR: 0.64; 95% CI: 0.56-0.73), respectively. In addition, minced meals were also associated with a difference between two methods, for the nursing assistants' whole tray (OR: 3.53; 95% CI: 1.66-7.51) and dietitians' food items (OR: 2.92; 95% CI: 1.37-6.22). Visual estimation by nursing assistants and dietitians correlated highly with the weighing method although the limits of agreement were wide. Nursing assistants and dietitians should pay attention to low consumption and modified texture meals when evaluating dietary intake using the visual estimation method. Copyright © 2016. Published by Elsevier Ltd.
Flexible Interior-Impression-Molding Tray
NASA Technical Reports Server (NTRS)
Anders, Jeffrey E.
1991-01-01
Device used inside combustion chamber of complicated shape for nondestructive evaluation of qualities of welds, including such features as offset, warping, misalignment of parts, and dropthrough. Includes flexible polypropylene tray trimmed to fit desired interior surface contour. Two neodymium boron magnets and inflatable bladder attached to tray. Tray and putty inserted in cavity to make mold of interior surface.
Develop and Manufacture an airlock sliding tray
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lawton, Cindy M.
2014-02-26
The goal of this project is to continue to develop an airlock sliding tray and then partner with an industrial manufacturing company for production. The sliding tray will be easily installed into and removed from most glovebox airlocks in a few minutes. Technical Approach: A prototype of a sliding tray has been developed and tested in the LANL cold lab and 35 trays are presently being built for the plutonium facility (PF-4). The current, recently approved design works for a 14-inch diameter round airlock and has a tray length of approximately 20 inches. The grant will take the already testedmore » and approved round technology and design for the square airlock. These two designs will be suitable for the majority of the existing airlocks in the multitude of DOE facilities. Partnering with an external manufacturer will allow for production of the airlock trays at a much lower cost and increase the availability of the product for all DOE sites. Project duration is estimated to be 12-13 months. Benefits: The purpose of the airlock sliding trays is fourfold: 1) Mitigate risk of rotator cuff injuries, 2) Improve ALARA, 3) Reduce risk of glovebox glove breaches and glove punctures, and 4) Improve worker comfort. I have had the opportunity to visit many other DOE facilities including Savannah, Y-12, ORNL, Sandia, and Livermore for assistance with ergonomic problems and/or injuries. All of these sites would benefit from the airlock sliding tray and I can assume all other DOE facilities with gloveboxes built prior to 1985 could also use the sliding trays.« less
Cochrane, R Bruce; Sindelar, Betty
2015-01-01
To evaluate the clinical effects of a prescription tray application of hydrogen peroxide gel as an adjunct to frequent maintenance appointments for refractory periodontal patients. Case series data were analyzed from 66 failing periodontal maintenance patients who had exhausted treatment options before using prescription trays with a 1.7% hydrogen peroxide gel once or twice daily for two-and-a-half to five years. Data included pocket probing depths (PPD), bleeding on probing (BOP), smoking status, and compliance with tray usage. Data were collected prior to tray usage and after tray delivery at six months, one year, and annual intervals. A clinical and statistical reduction in BOP was maintained over the length of the study (p ≤ 0.01). No differences were seen in patients who used trays two times or one time a day or in patients who smoked or did not smoke. The 1.7% peroxide delivered via a prescription tray was most effective in shallow pockets. Aggregate PPD distribution did not change significantly. Of clinical relevance, only one tooth out of 1,745 teeth studied was lost due to periodontal disease during the study period. Prescription tray application of peroxide gel, as an adjunct to frequent periodontal maintenance appointments for refractory patients, demonstrated significant reductions in BOP'for smokers and non-smokers who used tray delivery once or twice a day.
Gupta, Sonam; Balakrishnan, Dhanasekar
2017-01-01
Purpose. For a precise fit of multiple implant framework, having an accurate definitive cast is imperative. The present study evaluated dimensional accuracy of master casts obtained using different impression trays and materials with open tray impression technique. Materials and Methods. A machined aluminum reference model with four parallel implant analogues was fabricated. Forty implant level impressions were made. Eight groups (n = 5) were tested using impression materials (polyether and vinylsiloxanether) and four types of impression trays, two being custom (self-cure acrylic and light cure acrylic) and two being stock (plastic and metal). The interimplant distances were measured on master casts using a coordinate measuring machine. The collected data was compared with a standard reference model and was statistically analyzed using two-way ANOVA. Results. Statistically significant difference (p < 0.05) was found between the two impression materials. However, the difference seen was small (36 μm) irrespective of the tray type used. No significant difference (p > 0.05) was observed between varied stock and custom trays. Conclusions. The polyether impression material proved to be more accurate than vinylsiloxanether impression material. The rigid nonperforated stock trays, both plastic and metal, could be an alternative for custom trays for multi-implant impressions when used with medium viscosity impression materials. PMID:28348595
Wang, H Y; Lu, Y C; Shiau, Y Y; Tsou, D
1996-03-01
A coordinate measurement machine with laser probe was used to measure the vertical distortion of the casts produced by use of three types of impression materials (irreversible hydrocolloid, condensation silicone, and addition silicone) and two types of trays (stock and custom trays). Results indicated that all impression groups showed positive vertical distortion (ranging from 0.00566 to 0.30299 mm) at the edentulous ridges and palatal area. The amount of the vertical distortion was greatest at the palatal area and was followed by the high edentulous ridge and the low edentulous ridge. Addition silicone, with either custom tray or stock tray, was the most accurate impression material. Condensation silicone was more accurate than irreversible hydrocolloid in custom tray impression. However, in stock tray impression the irreversible hydrocolloid was more accurate than the condensation silicone. The results suggest that, with careful manipulation, irreversible hydrocolloid with stock tray impression may provide a satisfactory cast for fabricating the framework of a distal extension removable partial denture.
The effect of impression volume and double-arch trays on the registration of maximum intercuspation.
Hahn, Sara M; Millstein, Philip L; Kinnunen, Taru H; Wright, Robert F
2009-12-01
The type of double-arch trays used may affect occlusion. The purpose of this study was to determine what effect, if any, double-arch tray design and impression material volume had on the registration of maximum intercuspation (MI). Quadrant impressions were made on articulated fracture-resistant dental casts mounted in maximum intercuspation occlusion. Three types of sideless double-arch impression trays were used: First Bite with nylon webbing, Sultan's 3-Way with double crosshatch webbing, and Premium's 3-in-1 Tray with single crosshatch webbing. Vinyl polysiloxane impression material (Aquasil Ultra Rigid Fast Set) was distributed at 2 different volumes (5.4 ml and 8.3 ml), and 60 impressions were made (n=10). A weight of 1.2 kg was placed on the upper arm of an Artex articulator, ensuring complete closure. The impressions were allowed to polymerize for 5 minutes. After polymerization, specimens were placed on a light box, and a camera set at a fixed distance was used to capture the light transmission that was projected through the impression material. The camera transferred the information to an image analysis program (ImageJ). This system allowed the different amounts of light projected through the impression to be translated into a gray scale value (GSV), which was assigned a thickness value, in millimeters, of a specified occlusal contact area. To assess reliability of the experimental design, 10 control impressions were made by directly applying impression material onto the typodont. These were analyzed in the same manner as the impressions made with trays. A 2-way ANOVA comparing volume by tray type was used (alpha=.05). This was followed by a Tukey HSD test. There was no main effect for volume of impression material (P=.71). Tray type was significantly different (P<.001). Impressions made with Sultan trays were significantly less accurate than impressions made with First Bite or Premium impression trays. The Premium tray type had the highest mean (SD) GSV, 179.8 (8.1), significantly higher than First Bite (164.7 (19.8); P<.001) or Sultan (82.8 (7.4); P<.001) trays. This in vitro study demonstrated that certain trays hinder closure into MI, which may negatively affect the accuracy of record making.
Huang, Zhi; Wang, Xin-zhi; Hou, Yue-Zhong
2015-02-01
Making impressions for maxillectomy patients is an essential but difficult task. This study developed a novel method to fabricate individual trays by computer-aided design (CAD) and rapid prototyping (RP) to simplify the process and enhance patient safety. Five unilateral maxillectomy patients were recruited for this study. For each patient, a computed tomography (CT) scan was taken. Based on the 3D surface reconstruction of the target area, an individual tray was manufactured by CAD/RP. With a conventional custom tray as control, two final impressions were made using the different types of tray for each patient. The trays were sectioned, and in each section the thickness of the material was measured at six evenly distributed points. Descriptive statistics and paired t-test were used to examine the difference of the impression thickness. SAS 9.3 was applied in the statistical analysis. Afterwards, all casts were then optically 3D scanned and compared digitally to evaluate the feasibility of this method. Impressions of all five maxillectomy patients were successfully made with individual trays fabricated by CAD/RP and traditional trays. The descriptive statistics of impression thickness measurement showed slightly more uneven results in the traditional trays, but no statistical significance was shown. A 3D digital comparison showed acceptable discrepancies within 1 mm in the majority of cast areas. The largest difference of 3 mm was observed in the buccal wall of the defective areas. Moderate deviations of 1 to 2 mm were detected in the buccal and labial vestibular groove areas. This study confirmed the feasibility of a novel method of fabricating individual trays by CAD/RP. Impressions made by individual trays manufactured using CAD/RP had a uniform thickness, with an acceptable level of accuracy compared to those made through conventional processes. © 2014 by the American College of Prosthodontists.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anand, G.; Erickson, D.C.
1999-07-01
The distillation column is a key component of ammonia-water absorption units including advanced generator-absorber heat exchange (GAX) cycle heat pumps. The design of the distillation column is critical to unit performance, size, and cost. The distillation column can be designed with random packing, structured packing, or various tray configurations. A sieve-tray distillation column is the least complicated tray design and is less costly than high-efficiency packing. Substantial literature is available on sieve tray design and performance. However, most of the correlations and design recommendations were developed for large industrial hydrocarbon systems and are generally not directly applicable to the compactmore » ammonia-water column discussed here. The correlations were reviewed and modified as appropriate for this application, and a sieve-tray design model was developed. This paper presents the sieve-tray design methodology for highly compact ammonia-water columns. A conceptual design of the distillation column for an 8 ton vapor exchange (VX) GAX heat pump is presented, illustrating relevant design parameters and trends. The design process revealed several issues that have to be investigated experimentally to design the final optimized rectifier. Validation of flooding and weeping limits and tray/point efficiencies are of primary importance.« less
Chai, Mei; Tang, Xuyan; Liang, Guangku
2015-12-01
To investigate clinical effect of individual light-curing resin tray as edge plastic material in complete denture modulo. A total of 30 patients with poor condition for alveolar ridge of mandible were chosen individual tray with individual light-curing resin tray for material edge shaping or traditional individual impression tray for edge shaping cream to produce complete denture. The operability, questionnaire about denture retention, comfort, mucosal cases and chewing function in the process of shaping the edge were investigated three months later after wearing dentures. There was no significant difference in retention, comfort, mucosa and the chewing function between the two mandibular denture impression methods. However, the patients with individual light-curing resin tray as edge shaping material felt better in the process than that in the patients with die-cream as the edge shaping material (P<0.05). Furthermore, the manipulation with individual light-curing resin tray as edge shaping material is easy for doctor. Although the clinical effect of Individual light-curing resin tray material as the edge shaping material is equal to that of impression cream, it saves time and human resource. Moreover, it is more acceptable for the patients and thus it can be spread in clinics.
NASA Astrophysics Data System (ADS)
Guerra-García, J. M.; García-Gómez, J. C.
2009-01-01
A field experiment using trays was conducted at Ceuta's yachting harbour, North Africa, to study the effect in recolonization of placing trays with unpolluted defaunate sediments (fine and gross sands with low contents of organic matter) inside an enclosed yachting harbour characterized by high percentages of silt and clay and high concentrations of organic matter. Sediment recolonization in the trays was mainly undertaken by the species living naturally at the yachting harbour, which recolonized both uncontaminated gross and fine sand trays (such as the crustaceans Corophium runcicorne, Corophium sextonae and Nebalia bipes, the mollusc Parvicardium exiguum and the polychaete Pseudomalacoceros tridentata). However, other species like the polychaetes Cirriformia tentaculata and Platynereis dumerilii, although also abundant in the yachting harbour, were unable to colonize the trays through transport of larvae and/or adults in the water column. The recolonization was very quick, and after the first month, the values of abundance, species richness, diversity and evenness were similar in the experimental trays and in the reference area (yachting harbour). Although the multivariate analysis showed that the species composition differed between the trays and the reference area, there were no significant differences in recolonization of gross and fine sands, indicating that other factors different from the granulometry are modulating the recolonization patterns.
Automatic inoculating apparatus. [includes movable carraige, drive motor, and swabbing motor
NASA Technical Reports Server (NTRS)
Wilkins, J. R.; Mills, S. M. (Inventor)
1974-01-01
An automatic inoculating apparatus for agar trays is described and using a simple inoculating element, such as a cotton swab or inoculating loop. The apparatus includes a movable carriage for supporting the tray to be inoculated, a drive motor for moving the tray along a trackway, and a swabbing motor for automatically swabbing the tray during the movement. An actuator motor controls lowering of the inoculating element onto the tray and lifting of the inoculating element. An electrical control system, including limit microswitches, enables automatic control of the actuator motor and return of the carriage to the initial position after inoculating is completed.
Spectral infrared hemispherical reflectance measurements for LDEF tray clamps
NASA Technical Reports Server (NTRS)
Cromwell, B. K.; Shepherd, S. D.; Pender, C. W.; Wood, B. E.
1993-01-01
Infrared hemispherical reflectance measurements that were made on 58 chromic acid anodized tray clamps from LDEF are described. The measurements were made using a hemiellipsoidal mirror reflectometer with interferometer for wavelengths between 2-15 microns. The tray clamps investigated were from locations about the entire spacecraft and provided the opportunity for comparing the effects of atomic oxygen at each location. Results indicate there was essentially no dependence on atomic oxygen fluence for the surfaces studied, but there did appear to be a slight dependence on solar radiation exposure. The reflectances of the front sides of the tray clamps consistently were slightly higher than for the protected rear tray clamp surfaces.
Dustbathing in food particles does not remove feather lipids.
Scholz, B; Kjaer, J B; Petow, S; Schrader, L
2014-08-01
Within the European Union, dustbathing material in cage-housing systems for laying hens became compulsory in 2012. In practice, most producers use food particles as litter substrate. The feed is dropped in small amounts on scratching mats by an automatic transporting system. However, because dustbathing behavior is meant to remove stale lipids from hens' plumage, food particles may not be a suitable substrate due to their fat content. This study analyzes feather lipid concentration (FLC) of laying hens with access to food particles (F) or lignocellulose (L) as litter substrates. In each of 2 identical trials, 84 laying hens of 2 genotypes (Lohmann Selected Leghorn, Lohmann Brown) were kept in 12 compartments (7 hens each). Compartments were equipped with a grid floor and additionally contained a closed dustbathing tray holding F or L. Feather samples (150 feathers) were taken 2 times throughout the experiment. At 23 wk of age, 4 hens per compartment were sampled after they were allowed pair-wise access to a dustbath for 2.5 h and 3 hens were sampled without access to a dustbathing tray (control). After 10 wk of free access to the dustbathing trays, all hens were sampled again. In trial 2, an additional third sampling was made after dustbaths had been closed again for 6 wk. Here, 6 hens per compartment were sampled immediately before and after a dustbath. Dustbathing in F resulted in higher FLC compared with L and control (P < 0.001), whereas no significant difference was found between L and control (P = 0.103). When open access to litter was provided, hens had higher FLC in F compared with L (P < 0.001). The FLC immediately after dustbathing in F was higher compared with the level before dustbathing (P < 0.001), whereas it was lower after dustbathing in L (P = 0.006). These results show that F are not suitable litter material for laying hens because they lead to lipid accumulation on the plumage. © Poultry Science Association Inc.
Heat and Mass Transfer Measurements for Tray-Fermented Fungal Products
NASA Astrophysics Data System (ADS)
Jou, R.-Y.; Lo, C.-T.
2011-01-01
In this study, heat and mass transfer in static tray fermentation, which is widely used in solid-state fermentation (SSF) to produce fungal products, such as enzymes or koji, is investigated. Specifically, kinetic models of transport phenomena in the whole-tray chamber are emphasized. The effects of temperature, moisture, and humidity on microbial growth in large-scale static tray fermentation are essential to scale-up SSF and achieve uniform fermentation. In addition, heat and mass transfer of static tray fermentation of Trichoderma fungi with two tray setups—traditional linen coverings and stacks in a temperature-humidity chamber is examined. In both these setups, the following factors of fermentation were measured: air velocity, air temperature, illumination, pH, carbon dioxide (CO2) concentration, and substrate temperature, and the effects of bed height, moisture of substrate, and relative humidity of air are studied. A thin (1 cm) bed at 28 °C and 95 % relative humidity is found to be optimum. Furthermore, mixing was essential for achieving uniform fermentation of Trichoderma fungi. This study has important applications in large-scale static tray fermentation of fungi.
NASA Astrophysics Data System (ADS)
Cruz-Tirado, J. P.; Tapia-Blácido, Delia R.; Siche, Raúl
2017-08-01
The objective of this work was the proportion and size of cane bagasse fiber in the physical (density and thickness), mechanical (flexural strength and tensile at break) and thermal (TG and DTG) properties of trays made from sweet potato starch. A fiber size of 75-45 µm and a 2.5% ratio allowed to obtain trays with low thicknesses and densities, but with more compact structures that improved the mechanical properties of trays made from sweet potato starch alone. In addition, higher thermal stability and lower decomposition rate are shown for trays with fiber size 75-45 µm and ratios of 2.5% and 5%. These results show that the smaller fiber size improves the properties of the sweet potato starch trays and that these trays can be used to replace the expanded polymer (EPS) for use in dry foods.
Stulberg, S David; Goyal, Nitin
2015-10-01
Two goals of tibial tray placement in TKA are to maximize coverage and establish proper rotation. Our purpose was to utilize MRI information obtained as part of PSI planning to determine the impact of tibial tray design on the relationship between coverage and rotation. MR images for 100 consecutive knees were uploaded into PSI software. Preoperative planning software was used to evaluate 3 different tray designs: anatomic, symmetric, and asymmetric. Approximately equally good coverage was achieved with all three trays. However, the anatomic compared to symmetric/asymmetric trays required less malrotation (0.3° vs 3.0/2.4°; P < 0.001), with a higher proportion of cases within 5° of neutral (97% vs 73/77%; P < 0.001). In this study, the anatomic tibia optimized the relationship between coverage and rotation. Copyright © 2015 Elsevier Inc. All rights reserved.
Reddy, Jagan Mohan; Prashanti, E; Kumar, G Vinay; Suresh Sajjan, M C; Mathew, Xavier
2009-01-01
The dual-arch impression technique is convenient in that it makes the required maxillary and mandibular impressions, as well as the inter-occlusal record in one procedure. The accuracy of inter-abutment distance in dies fabricated from dual-arch impression technique remains in question because there is little information available in the literature. This study was conducted to evaluate the accuracy of inter-abutment distance in dies obtained from full arch dual-arch trays with those obtained from full arch stock metal trays. The metal dual-arch trays showed better accuracy followed by the plastic dual-arch and stock dentulous trays, respectively, though statistically insignificant. The pouring sequence did not have any effect on the inter-abutment distance statistically, though pouring the non-working side of the dual-arch impression first showed better accuracy.
Chen, H; Zhao, T; Wang, Y; Sun, Y C
2016-10-18
To establish a digital method for production of custom trays for edentulous jaws using fused deposition modeling (FDM) based on three-dimensional (3D) scans of primary jaw impressions, and to quantitatively evaluate the accuracy. A red modeling compound was used to make a primary impression of a standard maxillary edentulous plaster model. The plaster model data and the primary impression tissue surface data were obtained using a 3D scanner. In the Gemomagic 2012 software, several commands were used, such as interactive drawing curves, partial filling holes, local offset, bodily offset, bodily shell, to imitate clinical procedures of drawing tray boundary, filling undercut, buffer, and generating the tray body. A standard shape of tray handle was designed and attached to the tray body and the data saved as stereolithography (STL) format. The data were imported into a computer system connected to a 3D FDM printing device, and the custom tray for the edentulous jaw model was printed layer upon layer at 0.2 mm/layer, using polylactic acid (PLA) filament, the tissue surface of the tray was then scanned with a 3D scanner. The registration functions of Geomagic 2012 was used to register the 3-dimentional surface data, and the point-cloud deviation analysis function of the Imageware 13.0 system was used to analyze the error. The CAD data of the custom tray was registered to the scan data, and the error between them was analyzed. The scanned plaster model surface was registered to the scanned impression surface and the scanned tray data to the CAD data, then the distance between the surface of plaster model and the scanned tissue surface of the custom tray was measured in Imageware 13.0. The deviation between the computer aided design data and the scanned data of the custom tray was (0.17±0.20) mm, with (0.19±0.18) mm in the primary stress-bearing area, (0.17±0.22) mm in the secondary stress-bearing area, (0.30±0.29) mm in the border seal area, (0.08±0.06) mm in the buffer area; the space between the tissue faces of the plaster model and the scanned tissue surface of custom tray was (1.98±0.40) mm, with (1.85±0.24) mm in the primary stress-bearing area, (1.86±0.26) mm in the secondary stress-bearing area, (1.77±0.36) mm in the border seal area, (2.90±0.26) mm in the buffer area. With 3D scanning, computer aided design and FDM technology, an efficient means of custom tray production was established.
Heavy Nucleus Collector (HNC) project for the NASA Long Duration Exposure Facility (LDEF)
NASA Technical Reports Server (NTRS)
Tarle, Gregory
1990-01-01
The primary goal of the heavy nucleus collector (HNC) experiment was to obtain high resolution composition measurements for cosmic ray nuclei in the platinum-lead and actinide region of the periodic table. Secondary objectives include studies of selected groups of elements of lower charge. These goals were to be realized by orbiting a large area array of dielectric nuclear track detectors in space for several years. In this time sufficient actinide nuclei would be collected to determine the nucleosynthetic age of the cosmic radiation and the relative mix of r- and s-process elements in the cosmic ray source. The detector consists of approximately 50 trays assembled in pressurized canisters. Each tray would contain 8 half-stacks (4 stacks total) and an event thermometer which would record the temperature of each event at the time of exposure. Each stack would contain 7 layers of Rodyne-P, CR-39 and Cronar plastic track detectors interleaved with copper stripping foils. Upon return to Earth, detectors would be removed for analysis. Ultraheavy nuclei would have left tracks through the detector sheets that would be made visible after etching in a hot sodium hydroxide solution.
Evolution of the mandibular mesh implant.
Salyer, K E; Johns, D F; Holmes, R E; Layton, J G
1977-07-01
Between 1960 and 1972, the Dallas Veterans Administration Hospital Maxillofacial Research Laboratory developed and made over 150 cast-mesh implants. Successive designs were ovoid, circular, and double-lumened in cross section to improve implant strength, surface area for bioattachment, and adjustability. Sleeves, collars, and bows were employed in the assembly of these implants, with an acrylic condylar head attached when indicated. In 1972, our laboratory developed a mandibular mesh tray, cast in one piece on a single sprue, with preservation of the vertically adjustable ramus. Stainless steel replaced Vitallium because of its greater malleability. Essentially, a lost-wax technique is used to cast the mesh tray. The model of a mandibular segment is duplicated as a refractory model. Mesh wax, made in our own custom-made die, is adapted to the refractory model. The unit is then sprued and invested. The wax is fired our of the mold in a gas furnace. Casting is done by the transferral of molten stainless steel from the crucible to the mold by centrifugal force in an electro-induction casting machine. Other mesh implants that have been developed are made from wire mesh, Dacron mesh, cast Ticonium, and hydroformed titanium.
Unilateral neglect: further validation of the baking tray task.
Appelros, Peter; Karlsson, Gunnel M; Thorwalls, Annika; Tham, Kerstin; Nydevik, Ingegerd
2004-11-01
The Baking Tray Task is a comprehensible, simple-to-perform test for use in assessing unilateral neglect. The aim of this study was to validate further its use with stroke patients. The Baking Tray Task was compared with 2 versions of the Behaviour Inattention Test and a test for personal neglect. A total of 270 patients were subjected to a 3-item version of the Behaviour Inattention Test and 40 patients were subjected to an 8-item version of the Behaviour Inattention Test, besides the Baking Tray Task and the personal neglect test. The Baking Tray Task was more sensitive than the 3-item Behaviour Inattention Test, but the 8-item Behaviour Inattention Test was more sensitive than the Baking Tray Task. The best combination of any 3 tests was Baking Tray Task, Reading an article, and Figure copying; the 2 last-mentioned being a part of the 8-item Behaviour Inattention Test. Multi-item tests detect more cases of neglect than do single tests. However, it is tiresome for the patient to undergo a larger test battery than necessary. It is also time-consuming for the staff. Behavioural tests seem more appropriate when assessing neglect. The Baking Tray Task seems to be one of the most sensitive single tests, but its sensitivity can be further enhanced when it is used in combination with other tests.
106. INTERIOR OF CABLE TRAY TUNNEL, FROM LANDLINE INSTRUMENTATION ROOM ...
106. INTERIOR OF CABLE TRAY TUNNEL, FROM LANDLINE INSTRUMENTATION ROOM (106), LSB (BLDG. 770), TOWARDS CABLE TRAY SHED - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Preliminary impression techniques for microstomia patients
Kumar, K. Aswini; Bhat, Vinaya; Nair, K. Chandrasekheran; Suresh, Reshma
2016-01-01
The Prosthetic rehabilitation of microstomia patients presents difficulties at all the stages. The difficulty starts with the preliminary impression making. This is due to the tongue rigidity and the decreased oral opening. A maximum oral opening which is smaller than the size of the tray can make prosthetic treatment challenging. Due to the restricted mouth opening, insertion and removal of the impression trays is extremely cumbersome and various modifications of the trays have been used in the past. Among these are the flexible trays and the sectional trays used with different modes of reassembling the segments extra orally after the impression is made. This article reviews the literature published from 1971 to 2015 concerning preliminary impression techniques used in making impressions for patients with microstomia based on various tray designs. An electronic search was performed across three databases (PubMed, Science Direct and Google Scolar) for relevant citations. The keywords/combinations used for the search were microstomia, limited/constricted/restricted mouth opening/oral access, trismus, sectional trays, impressions and prosthetic/prosthodontic rehabilitation. The search was limited to papers written in English which resulted in a total of 45 related articles of which 17 articles were included for discussion of this review. PMID:27621540
1984-09-01
and these accompanied the sample residue through sieving to avoid sample mix- up . B. Field data sheets required logger’s initials on each page to A...ensure data completeness. C. Metal trays were placed to catch residue spillage during residue transfer from sieves to sample bottles. D. Sample bottles...methodologies were comparable for all sample e types and consisted of four sequential components: extraction, clean- up , gas chromatographic (GC) analysis, and
Vascular Blood Collection stowage in MELFI
2010-08-26
ISS024-E-012555 (26 Aug. 2010) --- NASA astronaut Tracy Caldwell Dyson, Expedition 24 flight engineer, replaces a dewar tray containing biological samples in the Minus Eighty Laboratory Freezer for ISS (MELFI-1) in the Kibo laboratory of the International Space Station.
Vascular Blood Collection stowage in MELFI
2010-08-26
ISS024-E-012553 (26 Aug. 2010) --- NASA astronaut Tracy Caldwell Dyson, Expedition 24 flight engineer, replaces a dewar tray containing biological samples in the Minus Eighty Laboratory Freezer for ISS (MELFI-1) in the Kibo laboratory of the International Space Station.
Automation of assembly of electrical products
NASA Astrophysics Data System (ADS)
Lebedenko, V. A.
1984-10-01
Approaches to the operation of a production line with a free rather than rigid tempo and cycles are discussed, along with the installation of a interoperational transport with trays rather than a continuously moving convey belt and the use of standard technological equipment in lieu of small scale mechanization. The design of a production line which follow these principles is examined. The advantages as well as the disadvantages of such a system are considered in the development of an automated flexible production line with robotized technological complex. A single flexible assembly line for the hookup operations with the most important link, the automatic manipulator for joining the product components together, consists of modules classifiable into six groups: (1) movers of the base parts; (2) feeders and orientators of parts; (3) joiners of parts; (4) carriers and holders of parts; (5) inspection and control systems; and (6) fasteners of parts.
Product management of making large pieces through Rapid Prototyping PolyJet® technology
NASA Astrophysics Data System (ADS)
Belgiu, G.; Cărăuşu, C.; Şerban, D.; Turc, C. G.
2017-08-01
The rapid prototyping process has already become a classic manufacturing process for parts and assemblies, either polymeric or metal parts. Besides the well-known advantages and disadvantages of the process, the use of 3D printers has a great inconvenience: the overall dimensions of the parts are limited. Obviously, there is a possibility to purchase a larger (and more expensive) 3D printer, but there are always larger pieces to be manufactured. One solution to this problem is the splitting of parts into several components that can be manufactured. The component parts can then be assembled in a single piece by known methods such as welding, gluing, screwing, etc. This paper shows our experience in making large pieces on the Strarasys® Objet24 printer, pieces larger than the tray sizes. The results obtained are valid for any 3D printer using the PolyJet® process.
A recirculating hydroponic system for studying peanut (Arachis hypogaea L.)
NASA Technical Reports Server (NTRS)
Mackowiak, C. L.; Wheeler, R. M.; Stutte, G. W.; Yorio, N. C.; Ruffe, L. M.; Sager, J. C. (Principal Investigator)
1998-01-01
Peanut (Arachis hypogaea L.) plants were grown hydroponically, using continuously recirculating nutrient solution. Two culture tray designs were tested; one tray design used only nutrient solution, while the other used a sphagnum-filled pod development compartment just beneath the cover and above the nutrient solution. Both trays were fitted with slotted covers to allow developing gynophores to reach the root zone. Peanut seed yields averaged 350 gm-2 dry mass, regardless of tray design, suggesting that substrate is not required for hydroponic peanut production.
Bleaching and temporomandibular disorder using a half tray design: a clinical report.
Robinson, F G; Haywood, V B
2000-05-01
A maxillary soft, custom-fitted tray was fabricated for a patient to perform nightguard vital bleaching. Treatment was interrupted after the patient experienced pain in the temporomandibular joint area shortly after wearing the bleaching prosthesis. The tray was trimmed so the labial, incisal and buccal cusps were covered and Sc) the patient had complete tooth-to-tooth contact in the maximum intercuspal position. The prosthesis proved to be retentive even without the presence of the bleaching material. The thick, sticky bleaching material was contained in the half tray design and the tray was held in place. The patient was able to continue the bleaching process for the 2-week duration necessary to achieve successful lightening of the teeth without further TMD symptoms.
García David, S; Cortijo Martínez, J A; Navarro Bermúdez, I; Maculé, F; Hinarejos, P; Puig-Verdié, L; Monllau, J C; Hernández Hermoso, J A
2014-01-01
The keel design of the tibial tray is essential for the transmission of the majority of the forces to the peripheral bone structures, which have better mechanical proprieties, thus reducing the risk of loosening. The aim of the present study was to compare the behaviour of different tibial tray designs submitted to torsional forces. Four different tibial components were modelled. The 3-D reconstruction was made using the Mimics software. The solid elements were generated by SolidWorks. The finite elements study was done by Unigraphics. A torsional force of 6 Nm. applied to the lateral aspects of each tibial tray was simulated. The GENUTECH® tibial tray, with peripheral trabecular bone support, showed a lower displacement and less transmitted tensions under torsional forces. The results suggest that a tibial tray with more peripheral support behaves mechanically better than the other studied designs. Copyright © 2013 SECOT. Published by Elsevier Espana. All rights reserved.
Silver Teflon blanket: LDEF tray C-08
NASA Technical Reports Server (NTRS)
Crutcher, E. Russ; Nishimura, L. S.; Warner, K. J.; Wascher, W. W.
1992-01-01
A study of the Teflon blanket surface at the edge of tray C-08 illustrates the complexity of the microenvironments on the Long Duration Exposure Facility (LDEF). The distribution of particulate contaminants varied dramatically over a distance of half a centimeter (quarter of an inch) near the edge of the blanket. The geometry and optical effects of the atomic oxygen erosion varied significantly over the few centimeters where the blanket folded over the edge of the tray resulting in a variety of orientations to the atomic oxygen flux. A very complex region of combined mechanical and atomic oxygen damage occurred where the blanket contacted the edge of the tray. A brown film deposit apparently fixed by ultraviolet light traveling by reflection through the Teflon film was conspicuous beyond the tray contract zone. Chemical and structural analysis of the surface of the brown film and beyond toward the protected edge of the blanket indicated some penetration of energetic atomic oxygen at least five millimeters past the blanket-tray contact interface.
Integrated Seawater Sampler and Data Acquisition System Prototype
1993-04-01
circuitry. The sample bags, initially sealed in a chemically clean environment , were opened by pumping the water out of the tray, thus forcing water into...the water sample containers from materials having low metals content. Control of the sample transfer environment through the use of Class-100 clean... environment . CTD designers also intended their underwater units and deck terminals to be connected directly together providing AC grounding appropriate to
Vascular Blood Collection stowage in MELFI
2010-08-26
ISS024-E-012546 (26 Aug. 2010) --- NASA astronaut Tracy Caldwell Dyson, Expedition 24 flight engineer, prepares to insert biological samples in a dewar tray in the Minus Eighty Laboratory Freezer for ISS (MELFI-1) in the Kibo laboratory of the International Space Station.
Vascular Blood Collection stowage in MELFI
2010-08-26
ISS024-E-012548 (26 Aug. 2010) --- NASA astronaut Tracy Caldwell Dyson, Expedition 24 flight engineer, prepares to insert biological samples in a dewar tray in the Minus Eighty Laboratory Freezer for ISS (MELFI-1) in the Kibo laboratory of the International Space Station.
Sorption of Organophosphorus Flame-Retardants on Settled ...
Dust is an important sink for indoor air pollutants, such as organophosphorus flame-retardants (OPFRs) that are used as additives in industrial and consumer products including electrical and electronic products, furniture, plastics, textile, and building/construction materials. This research investigated the sorption of OPFRs, tris(2-chloroethyl) phosphate (TCEP), tris(1-chlor-2-propyl) phosphate (TCPP), and tris(1,3-dichloro-2-propyl) phosphate (TDCPP) on settled Arizona Test Dust (ATD) using a dual small chamber system. During the test, seven free film release paper dust trays covered with ATD were placed in the sink test chamber. Constant gas phase OPFRs from the source chamber were dosed into the test chamber. The dust evenly spread on each dust tray was removed from the test chamber at different exposure times to determine the amount of OPFRs absorbed by the dust. The ATD has been characterized for a nominal particle size and surface area. The mass of dust on each of seven dust trays was weighed before the dust was placed inside the sink chamber. OPFRs concentrations at the inlet and faceplate of the test chamber were monitored by collecting polyurethane foam (PUF) samples. The OPFR exposed dust and PUF samples were extracted by 1:1 ethyl acetate/methylene chloride and analyzed on GC/MS. The data were used to calculate the OPFR sorption concentration on the dust through dust/air partition. Settled dust can adsorb OPFR from air. The sorption concentration wa
NASA Astrophysics Data System (ADS)
Brisset, Julie; Colwell, Joshua; Dove, Adrienne; Maukonen, Doug
2017-07-01
In an effort to better understand the early stages of planet formation, we have developed a 1.5U payload that flew on the International Space Station (ISS) in the NanoRacks NanoLab facility between September 2014 and March 2016. This payload, named NanoRocks, ran a particle collision experiment under long-term microgravity conditions. The objectives of the experiment were (a) to observe collisions between mm-sized particles at relative velocities of < 1 cm/s and (b) to study the formation and disruption of particle clusters for different particle types and collision velocities. Four types of particles were used: mm-sized acrylic, glass, and copper beads and 0.75 mm-sized JSC-1 lunar regolith simulant grains. The particles were placed in sample cells carved out of an aluminum tray. This tray was attached to one side of the payload casing with three springs. Every 60 s, the tray was agitated, and the resulting collisions between the particles in the sample cells were recorded by the experiment camera. During the 18 months the payload stayed on ISS, we obtained 158 videos, thus recording a great number of collisions. The average particle velocities in the sample cells after each shaking event were around 1 cm/s. After shaking stopped, the inter-particle collisions damped the particle kinetic energy in less than 20 s, reducing the average particle velocity to below 1 mm/s, and eventually slowing them to below our detection threshold. As the particle velocity decreased, we observed the transition from bouncing to sticking collisions. We recorded the formation of particle clusters at the end of each experiment run. This paper describes the design and performance of the NanoRocks ISS payload.
Brisset, Julie; Colwell, Joshua; Dove, Adrienne; Maukonen, Doug
2017-07-01
In an effort to better understand the early stages of planet formation, we have developed a 1.5U payload that flew on the International Space Station (ISS) in the NanoRacks NanoLab facility between September 2014 and March 2016. This payload, named NanoRocks, ran a particle collision experiment under long-term microgravity conditions. The objectives of the experiment were (a) to observe collisions between mm-sized particles at relative velocities of < 1 cm/s and (b) to study the formation and disruption of particle clusters for different particle types and collision velocities. Four types of particles were used: mm-sized acrylic, glass, and copper beads and 0.75 mm-sized JSC-1 lunar regolith simulant grains. The particles were placed in sample cells carved out of an aluminum tray. This tray was attached to one side of the payload casing with three springs. Every 60 s, the tray was agitated, and the resulting collisions between the particles in the sample cells were recorded by the experiment camera. During the 18 months the payload stayed on ISS, we obtained 158 videos, thus recording a great number of collisions. The average particle velocities in the sample cells after each shaking event were around 1 cm/s. After shaking stopped, the inter-particle collisions damped the particle kinetic energy in less than 20 s, reducing the average particle velocity to below 1 mm/s, and eventually slowing them to below our detection threshold. As the particle velocity decreased, we observed the transition from bouncing to sticking collisions. We recorded the formation of particle clusters at the end of each experiment run. This paper describes the design and performance of the NanoRocks ISS payload.
21 CFR 872.3670 - Resin impression tray material.
Code of Federal Regulations, 2010 CFR
2010-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3670 Resin impression tray material. (a) Identification. Resin impression tray material is a device intended for use in a two-step dental mold fabricating process. The device consists of a resin material, such as methyl methacrylate, and is used to form a...
21 CFR 872.3670 - Resin impression tray material.
Code of Federal Regulations, 2011 CFR
2011-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3670 Resin impression tray material. (a) Identification. Resin impression tray material is a device intended for use in a two-step dental mold fabricating process. The device consists of a resin material, such as methyl methacrylate, and is used to form a...
78 FR 23137 - Implementation of Full-Service Intelligent Mail Requirements for Automation Prices
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-18
..., which provides high-value services and enables efficient mail processing. Mailings must bear Intelligent Mail barcodes on mailpieces, trays, and containers, where applicable. Also, mailers must submit mailing... Intelligent Mail tray barcodes (IMtb) on trays, tubs, and sacks. Apply unique Intelligent Mail container...
Creation of fluorocarbon barriers on surfaces of starch-based products through cold plasma treatment
NASA Astrophysics Data System (ADS)
Han, Yousoo
Two kinds of starch foam trays (starch and aspen-starch foam trays) were produced using a lab model baking machine. Surfaces of the trays were treated with CF4 and SF6 plasma to create fluorine-rich layers on the surfaces, which might show strong water resistance. The plasma parameters, such like RF power, gas pressure and reaction time, were varied to evaluate the effects of each parameter on fluorination of surfaces. The atomic concentrations of fluorine, oxygen and carbon on samples' surfaces were earned from ESCA (electron spectroscopy for chemical analysis) and contact angles of sample surfaces were measured for hydrophobicity. For water resistance of plasma treated surfaces, liquid water uptake and water vapor uptake test were performed. Also, equilibrium moisture contents of unmodified and plasma treated samples were measured to evaluate biodegradability of plasma treated samples. Fluorine-rich barriers were created on sample surfaces treated with CF 4 and SF6 plasma. The fluorine atomic concentrations of treated sample surfaces were ranged from 34.4% to 64.4% (CF4 treatment) and 43.6% to 57.9% (SF6 treatment). It was found at both plasma gases that plasma parameters affected total fluorine concentration and carbon-peak shapes in ESCA surveys, which imply different distributions of mono- or multi-fluoro carbon's contents. In various reaction times, it was found that total fluorine contents were decreased after a critical point as the reaction time was prolonged, which may imply that a dominant mechanism has been changed from deposition or functionalization to etching. Oxygen atomic concentration was decreased at sample surfaces treated by both plasmas. In the case of SF6 plasma, it was proved that the removal of oxygen surely occurred because there was no addition of sulfur species. Plasma treated sample surfaces had high contact angles with distilled water up to 150° and the high values of angles have been kept constant up to for 15 minutes. Fluorine-rich barriers created by plasma showed lower water liquid and vapor permeability than untreated surfaces did. Plasma treated samples had similar moisture contents with untreated samples at all relative humidity tested. AFM and SEM images were taken for sample surfaces' morphology and topography.
Automated Parallel Capillary Electrophoretic System
Li, Qingbo; Kane, Thomas E.; Liu, Changsheng; Sonnenschein, Bernard; Sharer, Michael V.; Kernan, John R.
2000-02-22
An automated electrophoretic system is disclosed. The system employs a capillary cartridge having a plurality of capillary tubes. The cartridge has a first array of capillary ends projecting from one side of a plate. The first array of capillary ends are spaced apart in substantially the same manner as the wells of a microtitre tray of standard size. This allows one to simultaneously perform capillary electrophoresis on samples present in each of the wells of the tray. The system includes a stacked, dual carousel arrangement to eliminate cross-contamination resulting from reuse of the same buffer tray on consecutive executions from electrophoresis. The system also has a gel delivery module containing a gel syringe/a stepper motor or a high pressure chamber with a pump to quickly and uniformly deliver gel through the capillary tubes. The system further includes a multi-wavelength beam generator to generate a laser beam which produces a beam with a wide range of wavelengths. An off-line capillary reconditioner thoroughly cleans a capillary cartridge to enable simultaneous execution of electrophoresis with another capillary cartridge. The streamlined nature of the off-line capillary reconditioner offers the advantage of increased system throughput with a minimal increase in system cost.
Normative data for distal line bisection and baking tray task.
Facchin, Alessio; Beschin, Nicoletta; Pisano, Alessia; Reverberi, Cristina
2016-09-01
Line bisection is one of the tests used to diagnose unilateral spatial neglect (USN). Despite its wide application, no procedure or norms were available for the distal variant when the task was performed at distance with a laser pointer. Furthermore, the baking tray task was an ecological test aimed at diagnosing USN in a more natural context. The aim of this study was to collect normative values for these two tests in an Italian population. We recruited a sample of 191 healthy subjects with ages ranging from 20 to 89 years. They performed line bisection with a laser pointer on three different line lengths (1, 1.5, and 2 m) at a distance of 3 m. After this task, the subjects performed the baking tray task and a second repetition of line bisection to test the reliability of measurement. Multiple regression analysis revealed no significant effects of demographic variables on the performance of both tests. Normative cut-off values for the two tests were developed using non-parametric tolerance intervals. The results formed the basis for clinical use of these two tools for assessing lateralized performance of patients with brain injury and for diagnosing USN.
Motorized Positioning Apparatus Having Coaxial Carrousels.
Li, Qingbo; Kane, Thomas E.; Liu, Changsheng; Sonnenschein, Bernard; Sharer, Michael V.; Kernan, John R.
2002-04-02
An automated electrophoretic system is disclosed. The system employs a capillary cartridge having a plurality of capillary tubes. The cartridge has a first array of capillary ends projecting from one side of a plate. The first array of capillary ends are spaced apart in substantially the same manner as the wells of a microtitre tray of standard size. This allows one to simultaneously perform capillary electrophoresis on samples present in each of the wells of the tray. The system includes a stacked, dual carrousel arrangement to eliminate cross-contamination resulting from reuse of the same buffer tray on consecutive executions from electrophoresis. The system also has a gel delivery module containing a gel syringe/a stepper motor or a high pressure chamber with a pump to quickly and uniformly deliver gel through the capillary tubes. The system further includes a multi-wavelength beam generator to generate a laser beam which produces a beam with a wide range of wavelengths. An off-line capillary reconditioner thoroughly cleans a capillary cartridge to enable simultaneous execution of electrophoresis with another capillary cartridge. The streamlined nature of the off-line capillary reconditioner offers the advantage of increased system throughput with a minimal increase in system cost.
Fluid Delivery System For Capillary Electrophoretic Applications.
Li, Qingbo; Liu, Changsheng; Kane, Thomas E.; Kernan, John R.; Sonnenschein, Bernard; Sharer, Michael V.
2002-04-23
An automated electrophoretic system is disclosed. The system employs a capillary cartridge having a plurality of capillary tubes. The cartridge has a first array of capillary ends projecting from one side of a plate. The first array of capillary ends are spaced apart in substantially the same manner as the wells of a microtitre tray of standard size. This allows one to simultaneously perform capillary electrophoresis on samples present in each of the wells of the tray. The system includes a stacked, dual carrousel arrangement to eliminate cross-contamination resulting from reuse of the same buffer tray on consecutive executions from electrophoresis. The system also has a gel delivery module containing a gel syringe/a stepper motor or a high pressure chamber with a pump to quickly and uniformly deliver gel through the capillary tubes. The system further includes a multi-wavelength beam generator to generate a laser beam which produces a beam with a wide range of wavelengths. An off-line capillary reconditioner thoroughly cleans a capillary cartridge to enable simultaneous execution of electrophoresis with another capillary cartridge. The streamlined nature of the off-line capillary reconditioner offers the advantage of increased system throughput with a minimal increase in system cost.
2nd NUTRITION w/Repository collection period
2011-10-04
ISS029-E-015096 (4 Oct. 2011) --- In the International Space Station?s Kibo laboratory, NASA astronaut Mike Fossum, Expedition 29 commander, prepares to insert samples into a Minus Eighty Laboratory Freezer for ISS (MELFI-1) dewar tray for the second NUTRITION w/Repository collection period.
2nd NUTRITION w/Repository collection period
2011-10-04
ISS029-E-015110 (4 Oct. 2011) --- In the International Space Station?s Kibo laboratory, NASA astronaut Mike Fossum, Expedition 29 commander, inserts a dewar tray of samples into the Minus Eighty Laboratory Freezer for ISS (MELFI-1) for the second NUTRITION w/Repository collection period.
Alikhasi, Marzieh; Siadat, Hakimeh; Kharazifard, Mohammad Javad
2015-01-01
Objectives: The purpose of this study was to compare the accuracy of implant position transfer and surface detail reproduction using two impression techniques and materials. Materials and Methods: A metal model with two implants and three grooves of 0.25, 0.50 and 0.75 mm in depth on the flat superior surface of a die was fabricated. Ten regular-body polyether (PE) and 10 regular-body polyvinyl siloxane (PVS) impressions with square and conical transfer copings using open tray and closed tray techniques were made for each group. Impressions were poured with type IV stone, and linear and angular displacements of the replica heads were evaluated using a coordinate measuring machine (CMM). Also, accurate reproduction of the grooves was evaluated by a video measuring machine (VMM). These measurements were compared with the measurements calculated on the reference model that served as control, and the data were analyzed with two-way ANOVA and t-test at P= 0.05. Results: There was less linear displacement for PVS and less angular displacement for PE in closed-tray technique, and less linear displacement for PE in open tray technique (P<0.001). Also, the open tray technique showed less angular displacement with the use of PVS impression material. Detail reproduction accuracy was the same in all the groups (P>0.05). Conclusion: The open tray technique was more accurate using PE, and also both closed tray and open tray techniques had acceptable results with the use of PVS. The choice of impression material and technique made no significant difference in surface detail reproduction. PMID:27252761
STS-26 crewmembers experiment with microgravity and eat on middeck
NASA Technical Reports Server (NTRS)
1988-01-01
STS-26 Mission Specialist John M. Lounge, using a beverage container, experiments with microgravity as Commander Frederick H. Hauck (left) and MS David C. Hilmers (right) look on. Lounge freefloats as he closes in on a sphere of the red liquid drifting in front of his mouth. Hauck holds a spoon while sipping from a beverage container as he balances a meal tray assembly on his thighs. Hilmers, partially blocked by the open airlock hatch and holding a spoon and a can of food, pauses to watch the experiment. Automated Directional Solidification Furnace (ADSF) and forward middeck lockers appear on Lounge's right.
Silva, Alisson R; Rodrigues-Silva, Nilson; Pereira, Poliana S; Sarmento, Renato A; Costa, Thiago L; Galdino, Tarcísio V S; Picanço, Marcelo C
2017-12-05
The common blossom thrips, Frankliniella schultzei Trybom (Thysanoptera: Thripidae), is an important lettuce pest worldwide. Conventional sampling plans are the first step in implementing decision-making systems into integrated pest management programs. However, this tool is not available for F. schultzei infesting lettuce crops. Thus, the objective of this work was to develop a conventional sampling plan for F. schultzei in lettuce crops. Two sampling techniques (direct counting and leaf beating on a white plastic tray) were compared in crisphead, looseleaf, and Boston lettuce varieties before and during head formation. The frequency distributions of F. schultzei densities in lettuce crops were assessed, and the number of samples required to compose the sampling plan was determined. Leaf beating on a white plastic tray was the best sampling technique. F. schultzei densities obtained with this technique were fitted to the negative binomial distribution with a common aggregation parameter (common K = 0.3143). The developed sampling plan is composed of 91 samples per field and presents low errors in its estimates (up to 20%), fast execution time (up to 47 min), and low cost (up to US $1.67 per sampling area). This sampling plan can be used as a tool for integrated pest management in lettuce crops, assisting with reliable decision making in different lettuce varieties before and during head formation. © The Author(s) 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Kawasaki, Yui; Akamatsu, Rie; Tamaura, Yuki; Sakai, Masashi; Fujiwara, Keiko; Tsutsuura, Satomi
2018-02-12
The aim of this study was to examine differences in the validity of a visual estimation method for determining patients' meal intake between various meal types and supplied food items in hospitals and to find factors influencing the validity of a visual estimation method. There are two procedures by which we obtained the information on dietary intake of the patients in these hospitals. These are both by visual assessment from the meal trays at the time of their clearing, by the attending nursing staff and by weighing conducted by researchers. The following criteria are set for the target trays: A) standard or therapeutic meals, which are monitored by a doctor, for energy and/or protein and/or sodium; B) regular, bite-sized, minced and pureed meal texture, and C) half-portion meals. Visual assessment results were tested for their validity by comparing with the corresponding results of weighing. Differences between these two methods indicated the estimated and absolute values of nutrient intake. A total of 255 (76.1%) trays were included in the analysis out of the 335 possible trays and the results indicated that the energy consumption estimates by visual or weighing procedures are not significantly different (412 ± 173 kcal, p = 0.15). However, the mean protein consumption was significantly different (16.3 ± 6.7 g/tray, p < 0.01) between the two procedures. Compared with standard meals (38 ± 45 kcal, 1.9 ± 2.5 g/tray), raters significantly misestimated the energy and protein intake of half-portion meals (78 ± 65 kcal, 2.8 ± 2.2 g/tray, p = 0.01) but accurately estimated the protein intake of protein controlled meals (0.5 ± 0.6 g/tray, p = 0.03). Trays adding supplied food items were significantly misestimated for energy intake (66 ± 58 kcal/tray) compared to trays with no additions (32 ± 39 kcal/tray, p < 0.01). Moreover, the results of multivariable analysis demonstrated that supplied food items were significantly associated with increased odds of a difference between the two methods (OR: 3.84; 95% confidence interval [CI]: 1.07-13.85). There were high correlations between the visual estimation method and the weighing method measuring patients' dietary intake for various meal types and textures, except for meals with added supplied food items. Nursing staff need to be attentive to supplied food items. Copyright © 2018 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Shaffer, Harry L; Harnish, Delbert A; McDonald, Michael; Vernon, Reid A; Heimbuch, Brian K
2015-12-01
Sterilized packaging systems are designed to maintain the sterility of surgical instruments and devices from the time of sterilization until use. This study evaluated the effectiveness of rigid containers versus wrapped instrument trays, sterilized using North American sterilization protocols, to maintain a sterile internal environment poststerilization when challenged with aerosolized bacteria under dynamic environmental conditions. Using a custom aerosol chamber, 111 rigid containers of various durations of use (unused, used <5 years, used 5-9 years) and 161 wrapped trays using 3 grades of sterilization wrap were challenged with ~10(2) colony-forming units per liter of air containing aerosolized Micrococcus luteus with a count median particle size of 1 μm, while simultaneously experiencing air volume exchanges due to vacuum cycles-two 1-psi cycles, three 0.7-psi cycles, and three 0.4-psi cycles-to simulate air exchange events occurring during the sterilization, transportation, and storage of sterilized instrument trays in health care facilities. Of 111 rigid containers tested, 97 (87%) demonstrated bacterial ingress into the container. Of 161 wrapped trays, 0 (0%) demonstrated bacterial ingress into the tray. Contamination rates of rigid containers increased significantly with increasing duration of use. In this study using a dynamic bacterial aerosol challenge, sterilized wrapped trays demonstrated significantly greater protection than sterilized rigid containers against the ingress of airborne bacteria. Copyright © 2015. Published by Elsevier Inc.
Accuracy of a self-perforating impression tray for dental implants.
Marotti, Juliana; Tortamano, Pedro; Castilho, Tatiana R R N; Steagall, Washington; Wolfart, Stefan; Haselhuhn, Klaus
2014-10-01
Difficulties are involved in impression making with conventional open impression trays. The purpose of this study was to evaluate the accuracy of transferring implant impressions with a self-perforating impression tray. A reference model of a mandible was fabricated, and 4 implants were placed in the regions of the first premolars and lateral incisors (implants 1, 2, 3, 4). Ten impressions of the reference model with polyvinyl siloxane were made for each group; control (conventional open impression tray) and test (self-perforating impression tray; Miratray Implant). A metal bar was screw-retained on implant 1, and the gaps generated at the vestibular face of implants 3 and 4 were measured by optical microcopy. The 2-way ANOVA and least square difference post hoc test were used (α=.05). Higher mean (±SD) values were obtained for the test group than for the control group for both implants: implant 3: 150 ±84 μm for the test group, 73 ±63 μm for the control group (P=.019); implant 4: 129 ±65 μm for the test group, 62 ±61 μm for the control group (P=.04). The self-perforating impression tray provided less accuracy than the conventional open tray. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
2008-07-01
volume of the system is 64 L. The propeller pump is 2.6 m upstream from the bed sediment sample tray . Flows in the VOST are up to 1.54 m/s, generating...159 High Flow Water Year...160 Low Flow Water Year
Microwave Heating of TV-Dinner Type Products
USDA-ARS?s Scientific Manuscript database
Modified from an inverter-based microwave oven, a new microwave system was developed to pasteurize mechanically tenderized beef, inoculated with Escherichia coli O157:H7 and placed into a 12 oz CPET tray containing de-ionized water. The system allowed the sample surface temperature to first increas...
Growing Large Quantities of Containerized Seedlings
Tim Pittman
2002-01-01
The sowing of large quantities of longleaf pine (Pinus palustris Mill.) seed into trays depends on the quality of the seed and the timing of seed sowing. This can be accomplished with mechanization. Seed quality is accomplished by using a gravity table. Tray filling can be accomplished by using a ribbon-type soil mixer and an automated tray-filling...
ERIC Educational Resources Information Center
Zaferos, Melanie
2016-01-01
This investigation presents students with the challenge of determining the total number of eggs in a photograph of a stack of egg trays. The perspective of the photograph does not allow students to count all the individual eggs in the top tray but does allow them to see the number of eggs in one row and one column of the top tray. During this…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-05
... tray configurations. The experiments conducted range from micro-scale, in which very small (5 mg... burned under a large oxygen- depletion calorimeter. Other experiments include cone calorimetry, smoke and... tray of cables underneath a bank of radiant panels. The results of the small-scale experiments are to...
Stockert, Emily Walker; Langerman, Alexander
2014-10-01
Efficiency in the operating room has become a topic of great interest. This study aimed to quantify the percent use of instruments among common instrument trays across 4 busy surgical services: Otolaryngology, Plastic Surgery, Bariatric Surgery, and Neurosurgery. We further aimed to calculate the costs associated with tray and instrument sterilization, as well as the implications of missing or damaged instruments. This was a single-site, observational study conducted on the surgical instrumentation at a large academic medical center in Chicago. Data were collected through direct observation by a trained investigator. Operating room instrument use and labor time required for cleaning and repacking instrument trays in central sterile processing (CSP) were analyzed using descriptive statistics and linear regression. Institutional data on volume and expenses were gathered from hospital leadership. Forty-nine procedures and 237 individual trays were observed. Average instrument (±SD)use rates were 13.0% for Otolaryngology (±4.2%), 15.5% for Plastic Surgery (±2.9%), 18.2% for Bariatric Surgery (±5.0%), and 21.9% for Neurosurgery (±1.7%). An increasing number of instruments per tray was associated with decreased use and increased instrument error rate. Using recorded labor time, the cost of cleaning and repackaging an individual instrument was calculated to be $0.10. Adding in CSP operating expenses and instrument depreciation per use, total processing cost per instrument increases to $0.51 or more. Our study demonstrates that the percent use of instruments across surgical specialties and multiple tray types is low. Attention to tray composition may result in immediate and significant cost savings. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Berhouet, Julien; Kontaxis, Andreas; Gulotta, Lawrence V; Craig, Edward; Warren, Russel; Dines, Joshua; Dines, David
2015-04-01
Recent shoulder prostheses have introduced a concept of a universal humeral stem component platform that has an onlay humeral tray for the reverse total shoulder arthroplasty (RTSA). No studies have reported how humeral tray positioning can affect the biomechanics of RTSA. The Newcastle Shoulder Model was used to investigate the biomechanical effect of humeral tray positioning in the Biomet Comprehensive Total Shoulder System (Biomet, Warsaw, IN, USA) RTSA. Five humeral tray configuration positions were tested: no offset, and 5 mm offset in the anterior, posterior, medial, and lateral positions. Superior and inferior impingement were evaluated for abduction, scapular plane elevation, forward flexion, and external/internal rotation with the elbow at the side (adduction) and at 90° of shoulder abduction. Muscle lengths and moment arms (elevating and rotational) were calculated for the deltoid, the infraspinatus, the teres minor, and the subscapularis. Inferior impingement was not affected by the humeral tray position. There was less superior impingement during abduction, scapular plane elevation, and rotation with the shoulder when the tray was placed laterally or posteriorly. The subscapularis rotational moment arm was increased with a posterior offset, whereas infraspinatus and teres minor rotational moment arms were increased with an anterior offset. Very little change was observed for the deltoid elevating moment arm or for its muscle length. Positioning the humeral tray with posterior offset offers a biomechanical advantage for patients needing RTSA by decreasing superior impingement and increasing the internal rotational moment arm of the subscapularis, without creating inferior impingement. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Pastoret, Marie-Hélène; Bühler, Julia; Weiger, Roland
2017-01-01
PURPOSE To compare the dimensional accuracy of three impression techniques- a separating foil impression, a custom tray impression, and a stock tray impression. MATERIALS AND METHODS A machined mandibular complete-arch metal model with special modifications served as a master cast. Three different impression techniques (n = 6 in each group) were performed with addition-cured silicon materials: i) putty-wash technique with a prefabricated metal tray (MET) using putty and regular body, ii) single-phase impression with custom tray (CUS) using regular body material, and iii) two-stage technique with stock metal tray (SEP) using putty with a separating foil and regular body material. All impressions were poured with epoxy resin. Six different distances (four intra-abutment and two inter-abutment distances) were gauged on the metal master model and on the casts with a microscope in combination with calibrated measuring software. The differences of the evaluated distances between the reference and the three test groups were calculated and expressed as mean (± SD). Additionally, the 95% confidence intervals were calculated and significant differences between the experimental groups were assumed when confidence intervals did not overlap. RESULTS Dimensional changes compared to reference values varied between -74.01 and 32.57 µm (MET), -78.86 and 30.84 (CUS), and between -92.20 and 30.98 (SEP). For the intra-abutment distances, no significant differences among the experimental groups were detected. CUS showed a significantly higher dimensional accuracy for the inter-abutment distances with -0.02 and -0.08 percentage deviation compared to MET and SEP. CONCLUSION The separation foil technique is a simple alternative to the custom tray technique for single tooth restorations, while limitations may exist for extended restorations with multiple abutment teeth. PMID:28874996
Krishna Ch, Vamsi; Mahendranadh Reddy, K; Gupta, Nidhi; Mahadev Shastry, Y; Chandra Sekhar, N; Aditya, Venkat; Reddy, G V K Mohan
2013-01-01
Impression making is not only important but is also the most significant step in the fabrication of any fixed or removable prosthesis. Proper impression making may be hindered by certain pathologic conditions. Reduced mouth opening is one of the common mechanical obstructions for proper orientation of the impression tray in the patient's mouth. In patients with trismus induced by submucous fibrosis, the procedure may be even more difficult to carry out because of reduced tissue resiliency and obliteration of vestibular spaces. Use of sectional trays offers one of the alternatives to overcome the problem of restricted mouth opening. Fabrication of customized impression trays according to the patient dentition improves the accuracy of impression making. The present case reports describe the fabrication of sectional custom trays designed for dentulous patients with chronic tobacco-induced submucous fibrosis.
Variation in gypsy moth, with comparisons to other Lymantria spp.
Paul W. Schaefer
1991-01-01
Specimens of gypsy moth, Lymantria dispar (L.) sensu lato were displayed in museum trays. Many specimens were quarantine laboratory reared during the 1989 season to provide samples (wing venation, frozen adults, prepupal haemolymph, larval feeding behavior, egg mass hair color, head capsule coloration and larval development) for...
Shamey, Renzo; Zubair, Muhammad; Cheema, Hammad
2015-08-01
The aim of this study was twofold, first to determine the effect of field view size and second of illumination conditions on the selection of unique hue samples (UHs: R, Y, G and B) from two rotatable trays, each containing forty highly chromatic Natural Color System (NCS) samples, on one tray corresponding to 1.4° and on the other to 5.7° field of view size. UH selections were made by 25 color-normal observers who repeated assessments three times with a gap of at least 24h between trials. Observers separately assessed UHs under four illumination conditions simulating illuminants D65, A, F2 and F11. An apparent hue shift (statistically significant for UR) was noted for UH selections at 5.7° field of view compared to those at 1.4°. Observers' overall variability was found to be higher for UH stimuli selections at the larger field of view. Intra-observer variability was found to be approximately 18.7% of inter-observer variability in selection of samples for both sample sizes. The highest intra-observer variability was under simulated illuminant D65, followed by A, F11, and F2. Copyright © 2015 Elsevier Ltd. All rights reserved.
Carlos, N R; Bridi, E C; Amaral, Flb; França, Fmg; Turssi, C P; Basting, R T
The purpose of this study was to evaluate bleaching methods containing hydrogen peroxide (HP) or carbamide peroxide (CP), dispensed in customized or prefilled trays, in terms of color change, tooth sensitivity, gingival irritation, acceptance, and comfort. Seventy-five volunteers were randomly selected and distributed according to the whitening agent (n=25): 10% HP dispensed in prefilled trays (Opalescence Go 10%) and 9.5% HP (Pola Day) and 10% CP both delivered in customized trays (Opalescence PF 10%). HP was applied for 30 min/d for 14 days (d), and CP for 8 h/d for 14 days. Evaluations were performed at baseline and at 7 days and 14 days of treatment. Color change was measured with Commission internationale de l'éclairage color coordinates (L*, a*, b*), Vita Classical, and 3D Master scales. A visual analog scale was used to assess tooth sensitivity, acceptance of the method and degree of comfort of the tray. Gingival irritation was evaluated as present or absent and localized or generalized. Regarding gingival irritation, tray acceptance, and tooth sensitivity, no differences were observed among the groups at any time (p>0.05). As for degree of comfort, 10% HP showed lower scores (comfortable) than 10% CP, with significant differences (p<0.05) from the other groups (comfortable to very comfortable). In terms of ΔL, Δa, and ΔE, no difference was observed among the groups or between the time periods (p>0.05). The Δb average was higher at 14 days (p<0.05), and there was no difference among the groups (p>0.05). Localized gingival irritation was observed in both tray methods. Mild tooth sensitivity was observed with time, regardless of the bleaching agent concentration or the application time. Color change was similar for all the groups at 7 days and 14 days, but there was a greater reduction in the yellow hue at 14 days. All the bleaching methods were highly accepted and effective in promoting whitening. Although prefilled trays are generally comfortable, they proved less comfortable than customized trays.
Water reactive hydrogen fuel cell power system
Wallace, Andrew P; Melack, John M; Lefenfeld, Michael
2014-01-21
A water reactive hydrogen fueled power system includes devices and methods to combine reactant fuel materials and aqueous solutions to generate hydrogen. The generated hydrogen is converted in a fuel cell to provide electricity. The water reactive hydrogen fueled power system includes a fuel cell, a water feed tray, and a fuel cartridge to generate power for portable power electronics. The removable fuel cartridge is encompassed by the water feed tray and fuel cell. The water feed tray is refillable with water by a user. The water is then transferred from the water feed tray into a fuel cartridge to generate hydrogen for the fuel cell which then produces power for the user.
Water reactive hydrogen fuel cell power system
Wallace, Andrew P; Melack, John M; Lefenfeld, Michael
2014-11-25
A water reactive hydrogen fueled power system includes devices and methods to combine reactant fuel materials and aqueous solutions to generate hydrogen. The generated hydrogen is converted in a fuel cell to provide electricity. The water reactive hydrogen fueled power system includes a fuel cell, a water feed tray, and a fuel cartridge to generate power for portable power electronics. The removable fuel cartridge is encompassed by the water feed tray and fuel cell. The water feed tray is refillable with water by a user. The water is then transferred from the water feed tray into the fuel cartridge to generate hydrogen for the fuel cell which then produces power for the user.
Contact structure for use in catalytic distillation
Jones, Jr., Edward M.
1984-01-01
A method for conducting catalytic chemical reactions and fractionation of the reaction mixture comprising feeding reactants into a distillation column reactor contracting said reactant in liquid phase with a fixed bed catalyst in the form of a contact catalyst structure consisting of closed porous containers containing the catatlyst for the reaction and a clip means to hold and support said containers, which are disposed above, i.e., on the distillation trays in the tower. The trays have weir means to provide a liquid level on the trays to substantially cover the containers. In other words, the trays function in their ordinary manner with the addition thereto of the catalyst. The reaction mixture is concurrently fractionated in the column.
NASA Technical Reports Server (NTRS)
1974-01-01
The capabilities for preflight feeding of flight personnel and the supply and control of the space shuttle flight food system were investigated to determine ground support requirements; and the functional details of an onboard food system galley are shown in photographic mockups. The elements which were identified as necessary to the efficient accomplishment of ground support functions include the following: (1) administration; (2) dietetics; (3) analytical laboratories; (4) flight food warehouse; (5) stowage module assembly area; (6) launch site module storage area; (7) alert crew restaurant and disperse crew galleys; (8) ground food warehouse; (9) manufacturing facilities; (10) transport; and (11) computer support. Each element is discussed according to the design criteria of minimum cost, maximum flexibility, reliability, and efficiency consistent with space shuttle requirements. The galley mockup overview illustrates the initial operation configuration, food stowage locations, meal assembly and serving trays, meal preparation configuration, serving, trash management, and the logistics of handling and cleanup equipment.
Production of Dioxins and Furans from the Burning of Excess Gun Propellant
2011-01-01
This is done by positioning the charges on the surface of the ground, in a shallow trench, on a concrete slab or in metal trays and igniting them from...environment are not fully understood. Burning, whether on snow cover, the ground or a combustion plate ( concrete or steel), does not lead to complete...the values for the background samples. The results for the samples taken from under the burnt pads (at a soil depth of 0 to 1 cm, samples BOP-12
The LDEF ultra heavy cosmic ray experiment
NASA Technical Reports Server (NTRS)
Osullivan, D.; Thompson, A.; Bosch, J.; Keegan, R.; Wenzel, K.-P.; Smit, A.; Domingo, C.
1991-01-01
The Long Duration Exposure Facility (LDEF) Ultra Heavy Cosmic Ray Experiment (UHCRE) used 16 side viewing LDEF trays giving a total geometry factor for high energy cosmic rays of 30 sq m sr. The total exposure factor was 170 sq m sr y. The experiment is based on a modular array of 192 solid state nuclear track detector stacks, mounted in sets of 4 pressure vessels (3 experiment tray). The extended duration of the LDEF mission has resulted in a greatly enhanced potential scientific yield from the UHCRE. Initial scanning results indicate that at least 2000 cosmic ray nuclei with Z greater than 65 were collected, including the world's first statistically significant sample of actinides. Postflight work to date and the current status of the experiment are reviewed. Provisional results from analysis of preflight and postflight calibrations are presented.
Digital impression and jaw relation record for the fabrication of CAD/CAM custom tray.
Kanazawa, Manabu; Iwaki, Maiko; Arakida, Toshio; Minakuchi, Shunsuke
2018-03-16
This article describes the protocol of a digital impression technique to make an impression and recording of the jaw relationship of edentulous patients for the fabrication of CAD/CAM custom tray using computer-aided design and manufacturing (CAD/CAM) technology. Scan the maxillary and mandibular edentulous jaws using an intraoral scanner. Scan the silicone jig with the maxillary and mandibular jaws while keeping the jig between the jaws. Import the standard tessellation language data of the maxillary and mandibular jaws and jig to make a jaw relation record and fabricate custom trays (CAD/CAM trays) using a rapid prototyping system. Make a definitive impression of the maxillary and mandibular jaws using the CAD/CAM trays. Digitalization of the complete denture fabrication process can simplify the complicated treatment and laboratory process of conventional methods In addition, the proposed method enables quality control regardless of the operator's experience and technique. Copyright © 2018. Published by Elsevier Ltd.
Image Processing Techniques for Assessment of Dental Trays
2001-10-25
170 patients having Angle Class I molar relationships with minor malocclusions and teeth including second molars fully erupted without loss of tooth...Abstract-A tray selected for the dental patient must adapt to the curvature of the teeth and allow the impression material to be in appropriate...brands of perforated metal trays with 170 lower arch cast models collected from patients having Angle Class 1 type occlusion with minor malocclusions
Non Destructive Seal Testing Polymeric Tray
2006-10-01
School of Enviromental and Biological Science Rutgers, The State University of New Jersey New Brunswick, New Jersey 08903 Principal Investigator...plate to accept new tray • Insert tray • Push “Continue” button • Lower upper compression plate and hold in position (80 psig) • Raise bottom...John J. Kingman Rd. Fort Belvoir, VA 22060-6221 Contractor: Rutgers, The State University of New Jersey THE CENTER FOR ADVANCED FOOD TECHNOLOGY
Lu, L; Wu, R S S
2007-02-01
A field experiment was carried out in Hong Kong to study the patterns of recolonization and succession of subtidal macrobenthos in defaunated sediment contaminated with industrial wastes and to determine the time required for benthic recovery in the industrial-contaminated sediment. A total of 50 species was found with an average of 172 animals/tray and 24 species/tray recorded one month after deployment. Initial colonizers were predominantly polychaetes (96 animals/tray, accounting for 55.7%) and gastropods (47 animals/tray, accounting for 27.2%). Abundance of macrobenthos increased quickly to a peak (505 animals/tray) after four months, declined afterwards, and increased again till the end of the experiment. Species number peaked (57 species/tray) in the same month as abundance did, and gradually declined thereafter. Abundance, species number and diversity were significantly lower in the industrial-contaminated sediment as compared to the controls during the early successional stages, indicating the harmful effects of industrial wastes on recolonization and succession of macrobenthos. Although no significant differences in community parameters between the industrial-contaminated and the control sediments were found after eleven months, significant difference in species composition still existed after fourteen months, showing a relatively long-term impact of industrial wastes on macrobenthic community structure.
Sundfeld, Daniel; Pavani, Caio Cesar; Schott, Timm Cornelius; Machado, Lucas Silveira; Pini, Núbia Inocêncya Pavesi; Bertoz, André Pinheiro de Magalhães; Sundfeld, Renato Herman
2018-04-20
The present dental bleaching case report describes a new method that precisely quantifies the daily wearing-times of the bleaching product by inserting a microsensor in the acetate custom tray. The bleaching efficacy was also discussed since the patient was previously submitted to enamel microabrasion. The patient was submitted to enamel microabrasion in 1987, and bleaching treatment was performed in 2005. In 2017, re-bleaching was executed using 10% peroxide carbamide. The electronic microsensor, TheraMon (TheraMon® microelectronic system; Sales Agency Gschladt, Hargelsberg, Austria), was embedded in the labial region of the upper and lower acetate trays to evaluate the wearing-times of the acetate trays/bleaching product. The patient was instructed to wear the tray for 6 to 8 h/day while sleeping. After 24 days of bleaching treatment, the data obtained from the TheraMon electronic devices was collected and interpreted. The patient did not entirely follow the bleaching treatment as recommended, as there was no evidence of use of the upper and lower trays for some days; additionally, the bleaching product was used for shorter and longer periods than was instructed. The TheraMon microeletronic device precisely measured the wearing-times of the acetate tray/bleaching product during the bleaching treatment. Teeth submitted to enamel microabrasion presented with a healthy clinical appearance after 30 years. Measuring the length and frequency of use of an acetate tray/bleaching product can be important to clinicians and patients for obtaining a controlled and adequate bleaching treatment.
Applications of T-ray spectroscopy in the petroleum field
NASA Astrophysics Data System (ADS)
Al-Douseri, Fatemah M.
2005-11-01
Because of heavy usage of petroleum products, which are the main source of energy in daily life and industry, a fast, reliable, and portable analysis system is needed to complement traditional techniques. Terahertz (THz) radiation, or T-rays, is electromagnetic radiation in the 0.1 to 10 THz frequency range. One unique attribute of T-rays is their ability to sensitively measure the induced molecular dipole moments in non-polar liquids such as aromatics, which make up the majority of the contents of many petroleum products. This information can lead to several applications in petroleum analysis. The application of T-rays to petroleum product analysis has the potential to make a significant impact in the petroleum field. In this dissertation, I show the first use of T-ray time-domain spectroscopy and Fourier transform infrared (FTIR) spectroscopy techniques for petroleum product analysis. I report on the feasibility of analyzing selected petroleum products, including gasoline, diesel, lubricating oil, and selected compounds of toluene, ethylbenzene, and xylene (BTEX). With the use of a T-ray time-domain spectrometer. I demonstrate that gasolines with different octane numbers and diesel all show specific absorption coefficients and refractive indexes in the spectral range from 0.5 to 2.0 THz. Furthermore, I report the qualitative and quantitative analysis of selected BTEX components in gasoline and diesel using FTIR spectroscopy in the 50 to 650 cm-1 region. I distinguish gasolines with different octane numbers from diesel and lubricating oil according to their different spectral features. I also determine the concentration of (o, m, p) xylene isomers in gasoline according to their specific absorption bands. The experimental results in this thesis, imply that linking between the knowledge of petroleum products and the development of T-ray spectrometer with the cooperation of industry might translate the T-ray spectroscopic system into a real world application in refineries, gas stations, and automobiles.
Effects of the LDEF orbital environment on the reflectance of optical mirror materials
NASA Technical Reports Server (NTRS)
Herzig, Howard; Fleetwood, Charles, Jr.
1995-01-01
Specimens of eight different optical mirror materials were flown in low earth orbit as part of the Long Duration Exposure Facility (LDEF) manifest to determine their ability to withstand exposure to the residual atomic oxygen and other environmental effects at those altitudes. Optical thin films of aluminum, gold, iridium, osmium, platinum, magnesium fluoride-overcoated aluminum and reactively deposited, silicon monoxide-protected aluminum, all of which were vacuum deposited on polished fused silica substrates, were included as part of Experiment S0010, Exposure of Spacecraft Coatings. Two specimens of polished, chemical vapor deposited (CVD) silicon carbide were installed in sites available in Experiment A0114, Interaction of Atomic Oxygen with Solid Surfaces at Orbital Altitudes, which included trays in two of the spacecraft bays, one on the leading edge and the other on the trailing edge. One of the silicon carbide samples was located in each of these trays. This paper will compare specular reflectance data from the preflight and postflight measurements made on each of these samples and attempt to explain the changes in light of the specific environments to which the experiments were exposed.
Micrometeoroids and debris on LDEF
NASA Technical Reports Server (NTRS)
Mandeville, Jean-Claude
1992-01-01
Part of the LDEF tray allocated to French Experiments (FRECOPA) was devoted to the study of dust particles. The tray was located on the face of LDEF directly opposed to the velocity vector. Two passive experiments were flown: a set of glass and metallic samples; and multilayer thin foil detectors. Crater size distribution made possible the evaluation of the incident microparticle flux in the near environment. Comparisons are made with measurements obtained on the other faces of LDEF and with results from similar experiments on the MIR. Of interest was the study of impact features on stacked thin foil detectors. The top foil acted as a shield, fragmenting the projectiles and spreading the fragments over the surface of the thick plate located underneath. EDS analysis has provided evidence of impactor fragments. Detectors consisting of a thin shield and thick bottom plate appear to offer a significantly higher return of data concerning chemical analysis of impactor residues than single plate detectors. The samples of various materials offer a unique opportunity for the study of the many processes involved upon hypervelocity impact phenomena.
Will Tray Rations be Available for the Next War?
1990-03-18
industry giants into the competition. Companies like Pillsbury and Green Giant competed for the opportunity to enter the T- Ration market.5 However...document may not be released for open pubicatio and it hu been cleaed by dw appmpriat militay ase or Ipoemment alency. WILL TRAY RATIONS BE AVAILABLE...TITLE (and Subtitle) -- T yPE OF REPORT & PERIOD COVERED Will Tray Rations Be Available For the Next War? Study Project 6. PERFORMING ORG. REPORT
Contact structure for use in catalytic distillation
Jones, E.M. Jr.
1984-03-27
A method is described for conducting catalytic chemical reactions and fractionation of the reaction mixture comprising feeding reactants into a distillation column reactor, contracting said reactant in liquid phase with a fixed bed catalyst in the form of a contact catalyst structure consisting of closed porous containers containing the catalyst for the reaction and a clip means to hold and support said containers, which are disposed above, i.e., on the distillation trays in the tower. The trays have weir means to provide a liquid level on the trays to substantially cover the containers. In other words, the trays function in their ordinary manner with the addition thereto of the catalyst. The reaction mixture is concurrently fractionated in the column. 7 figs.
Contact structure for use in catalytic distillation
Jones, Jr., Edward M.
1985-01-01
A method and apparatus for conducting catalytic chemical reactions and fractionation of the reaction mixture, comprising and feeding reactants into a distillation column reactor contracting said reactant in a liquid phase with a fixed bed catalyst in the form of a contact catalyst structure, consisting of closed porous containers containing the catalyst for the reaction and a clip means to hold and support said containers, which are disposed above, i.e., on the distillation trays in the tower. The trays have weir means to provide a liquid level on the trays to substantially cover the containers. In other words, the trays function in their ordinary manner with the addition thereto of the catalyst. The reaction mixture is concurrently fractionated in the column.
Contact structure for use in catalytic distillation
Jones, E.M. Jr.
1985-08-20
A method and apparatus are disclosed for conducting catalytic chemical reactions and fractionation of the reaction mixture, comprising and feeding reactants into a distillation column reactor contracting said reactant in a liquid phase with a fixed bed catalyst in the form of a contact catalyst structure, consisting of closed porous containers containing the catalyst for the reaction and a clip means to hold and support said containers, which are disposed above, i.e., on the distillation trays in the tower. The trays have weir means to provide a liquid level on the trays to substantially cover the containers. In other words, the trays function in their ordinary manner with the addition thereto of the catalyst. The reaction mixture is concurrently fractionated in the column. 7 figs.
Focused Ion Beam Recovery of Hypervelocity Impact Residue in Experimental Craters on Metallic Foils
NASA Technical Reports Server (NTRS)
Graham, G. A.; Teslich, N.; Dai, Z. R.; Bradley, J. P.; Kearsley, A. T.; Horz, F.
2006-01-01
The Stardust sample return capsule will return to Earth in January 2006 with primitive debris collected from Comet 81P/Wild-2 during the fly-by encounter in 2004. In addition to the cometary particles embedded in low-density silica aerogel, there will be microcraters preserved in the Al foils (1100 series; 100 micrometers thick) that are wrapped around the sample tray assembly. Soda lime spheres (approximately 49 m in diameter) have been accelerated with a light-gas-gun into flight-grade Al foils at 6.35 km s(sup -1) to simulate the potential capture of cometary debris. The preserved crater penetrations have been analyzed using scanning electron microscopy (SEM) and x-ray energy dispersive spectroscopy (EDX) to locate and characterize remnants of the projectile material remaining within the craters. In addition, ion beam induced secondary electron imaging has proven particularly useful in identifying areas within the craters that contain residue material. Finally, high-precision focused ion beam (FIB) milling has been used to isolate and then extract an individual melt residue droplet from the interior wall of an impact penetration. This enabled further detailed elemental characterization, free from the background contamination of the Al foil substrate. The ability to recover pure melt residues using FIB will significantly extend the interpretations of the residue chemistry preserved in the Al foils returned by Stardust.
Polylactic acid trays for fresh-food packaging: A Carbon Footprint assessment.
Ingrao, Carlo; Tricase, Caterina; Cholewa-Wójcik, Agnieszka; Kawecka, Agnieszka; Rana, Roberto; Siracusa, Valentina
2015-12-15
This paper discusses application of Carbon Footprint (CF) for quantification of the 100-year Global Warming Potential (GWP100) associated with the life cycle of polylactic acid (PLA) trays for packaging of fresh foods. A comparison with polystyrene (PS)-based trays was done considering two different transport system scenarios for PLA-granule supply to the tray production firm: a transoceanic freight vessel and an intercontinental freight aircraft. Doing so enabled estimation of the influence of the transportation phase on the GHG-emission rate associated with the PLA-trays' life cycle. From the assessment, the GWP100 resulted to be mainly due to PLA-granulate production and to its transportation to the tray manufacturing facility. Also, the study documented that, depending upon the transport system considered, the CF associated with the life cycle of the PLA trays can worsen so much that the latter are no longer GHG-emission saving as they are expected to be compared to the PS ones. Therefore, based upon the findings of the study, it was possible for the authors to understand the importance and the need of accounting for the transport-related issues in the design of PLA-based products, thus preserving their environmental soundness compared to traditional petroleum-based products. In this context, the study could be used as the base to reconsider the merits of PLA usage for product manufacturing, especially when high distances are implied, as in this analysed case. So, the authors believe that new research and policy frameworks should be designed and implemented for both development and promotion of more globally sustainable options. Copyright © 2015 Elsevier B.V. All rights reserved.
Zhou, Li-bin; Shang, Hong-tao; He, Li-sheng; Bo, Bin; Liu, Gui-cai; Liu, Yan-pu; Zhao, Jin-long
2010-09-01
To improve the reconstructive surgical outcome of a discontinuous mandibular defect, we used reverse engineering (RE), computer-aided design (CAD), and rapid prototyping (RP) technique to fabricate customized mandibular trays to precisely restore the mandibular defects. Autogenous bone grafting was also used to restore the bony continuity for occlusion rehabilitation. Six patients who had undergone block resection of the mandible underwent reconstruction using a custom titanium tray combining autogenous iliac grafts. The custom titanium tray was made using a RE/CAD/RP technique. A virtual 3-dimensional model was obtained by spiral computed tomography scanning. The opposite side of the mandible was mirrored to cover the defect area to restore excellent facial symmetry. A bone grafting tray was designed from the mirrored image and manufactured using RP processing and casting. The mandibular defects were restored using the trays in combination of autologous iliac grafting. An implant denture was made for 1 of the 6 patients at 24 weeks postoperatively for occlusion rehabilitation. The trays fabricated using this technique fit well in all 6 patients. The reconstructive procedures were easy and time saving. Satisfactory facial symmetry was restored. No severe complications occurred in the 5 patients without occlusion rehabilitation during a mean 50-month follow-up period. The reconstruction in the patient with occlusion lasted for only 1 year and failed eventually because of bone resorption and infection. Mandibular reconstruction was facilitated using the RE/CAD/RP technique. Satisfactory esthetic results were achieved. However, the rigidity of the cast tray could cause severe stress shielding to the grafts, which could lead to disuse atrophy. Therefore, some modification is needed for functional reconstruction. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Template-directed instrumentation in total knee arthroplasty: cost savings analysis.
Hsu, Andrew R; Gross, Christopher E; Bhatia, Sanjeev; Levine, Brett R
2012-11-01
The use of digital radiography and templating software in total knee arthroplasty (TKA) continues to become more prevalent as the number of procedures performed increases every year. Template-directed instrumentation (TDI) is a novel approach to surgical planning that combines digital templating with limited intraoperative instruments. The purpose of this study was to evaluate the financial implications and radiographic outcomes of using TDI to direct instrumentation during primary TKA. Over a 1-year period, 82 consecutive TKAs using TDI were retrospectively reviewed. Patient demographics and preoperative templated sizes of predicted components were recorded, and OrthoView digital planning software (OrthoView LLC, Jacksonville, Florida was used to determine the 2 most likely tibial and femoral component sizes for each case. This sizing information was used to direct component vendors to prepare 3 lightweight instrument trays based on these sizes. The sizes of implanted components and the number of total trays required were documented. A cost savings analysis was performed to compare TDI and non-TDI surgical expenses for TKA. In 80 (97%) of 82 cases, the prepared sizes determined by TDI using 3 instrument trays were sufficient. Preoperative templating correctly predicted the size of the tibial and femoral component sizes in 90% and 83% of cases, respectively. The average number of trays used with TDI was 3.0 (range, 3-5 trays) compared with 7.5 (range, 6-9 trays) used in 82 preceding non-TDI TKAs. Based on standard fees to sterilize and package implant trays (approximately $26 based on a survey of 10 orthopedic hospitals performing TKA), approximately $9612 was saved by using TDI over the 1-year study period. Overall, digital templating and TDI were a simple and cost-effective approach when performing primary TKA. Copyright 2012, SLACK Incorporated.
Civeira, G; Lavado, R S
2008-09-01
Urban soils may suffer mild to severe degradation as a result of physical and chemical alterations. To reconstruct these soils, a new upper horizon must be created, usually through the application of organic matter, one source of which is biosolids. Different soil mixtures were evaluated with regard to loss of nitrates in percolates and the uptake and incorporation of nutrients and heavy metals into plant tissues. The experiment was conducted in trays; treatments were mixtures of biosolids and a coarse material (e.g., sand or pine wood sawdust), combined in different proportions. Randomized trays were seeded with a mix of tall fescue (Festuca arundinacea L.) and perennial ryegrass (Lolium perenne L.). Plant biomass was quantified. Nitrates in percolates were measured, as were nutrients and heavy metals in mixtures and plant tissues. Plants accumulated substantially more N, and biomass was 40% higher, in the treatments with higher levels of biosolids. The same treatments released more nitrogen and resulted in higher percolate nitrate levels. Plants had normal concentrations of all nutrients, except nitrogen, which was low. Heavy metal concentrations were not significantly different among treatments. Based on the analysis of these data, the proportion of biosolids appears to be the most important factor affecting the quality of reconstructed soil and the rate of improvement. The type of coarse material used did not significantly affect the outcome.
Mechanical impedance of soil crusts and water content in loamy soils
NASA Astrophysics Data System (ADS)
Josa March, Ramon; Verdú, Antoni M. C.; Mas, Maria Teresa
2013-04-01
Soil crust development affects soil water dynamics and soil aeration. Soil crusts act as mechanical barriers to fluid flow and, as their mechanical impedance increases with drying, they also become obstacles to seedling emergence. As a consequence, the emergence of seedling cohorts (sensitive seeds) might be reduced. However, this may be of interest to be used as an effective system of weed control. Soil crusting is determined by several factors: soil texture, rain intensity, sedimentation processes, etc. There are different ways to characterize the crusts. One of them is to measure their mechanical impedance (MI), which is linked to their moisture level. In this study, we measured the evolution of the mechanical impedance of crusts formed by three loamy soil types (clay loam, loam and sandy clay loam, USDA) with different soil water contents. The aim of this communication was to establish a mathematical relationship between the crust water content and its MI. A saturated soil paste was prepared and placed in PVC cylinders (50 mm diameter and 10 mm height) arranged on a plastic tray. Previously the plastic tray was sprayed with a hydrophobic liquid to prevent the adherence of samples. The samples on the plastic tray were left to air-dry under laboratory conditions until their IM was measured. To measure IM, a food texture analyzer was used. The equipment incorporates a mobile arm, a load cell to apply force and a probe. The arm moves down vertically at a constant rate and the cylindrical steel probe (4 mm diameter) penetrates the soil sample vertically at a constant rate. The equipment is provided with software to store data (time, vertical distance and force values) at a rate of up to 500 points per second. Water content in crust soil samples was determined as the loss of weight after oven-drying (105°C). From the results, an exponential regression between MI and the water content was obtained (determination coefficient very close to 1). This methodology allows the prediction of the potential mechanical behaviour of soil crusts generated during soil drying, from initial saturated soil conditions (e.g. waterlogging conditions).
Extreme-UV lithography vacuum chamber zone seal
Haney, Steven J.; Herron, Donald Joe; Klebanoff, Leonard E.; Replogle, William C.
2001-01-01
Control of particle contamination on the reticle and carbon contamination of optical surfaces in photolithography systems can be achieved by the establishment of multiple pressure zones in the photolithography systems. The different zones will enclose the reticle, projection optics, wafer, and other components of system. The system includes a vacuum apparatus that includes: a housing defining a vacuum chamber; one or more metrology trays situated within the vacuum chamber each of which is supported by at least one support member, wherein the tray separates the vacuum chamber into a various compartments that are maintained at different pressures; and conductance seal devices for adjoining the perimeter of each tray to an inner surface of the housing wherein the tray is decoupled from vibrations emanating from the inner surface of the housing.
Extreme-UV lithography vacuum chamber zone seal
Haney, Steven J.; Herron, Donald Joe; Klebanoff, Leonard E.; Replogle, William C.
2003-04-08
Control of particle contamination on the reticle and carbon contamination of optical surfaces in photolithography systems can be achieved by the establishment of multiple pressure zones in the photolithography systems. The different zones will enclose the reticle, projection optics, wafer, and other components of system. The system includes a vacuum apparatus that includes: a housing defining a vacuum chamber; one or more metrology trays situated within the vacuum chamber each of which is supported by at least one support member, wherein the tray separates the vacuum chamber into a various compartments that are maintained at different pressures; and conductance seal devices for adjoining the perimeter of each tray to an inner surface of the housing wherein the tray is decoupled from vibrations emanating from the inner surface of the housing.
Extreme-UV lithography vacuum chamber zone seal
Haney, Steven J.; Herron, Donald Joe; Klebanoff, Leonard E.; Replogle, William C.
2003-04-15
Control of particle contamination on the reticle and carbon contamination of optical surfaces in photolithography systems can be achieved by the establishment of multiple pressure zones in the photolithography systems. The different zones will enclose the reticle, projection optics, wafer, and other components of system. The system includes a vacuum apparatus that includes: a housing defining a vacuum chamber; one or more metrology trays situated within the vacuum chamber each of which is supported by at least one support member, wherein the tray separates the vacuum chamber into a various compartments that are maintained at different pressures; and conductance seal devices for adjoining the perimeter of each tray to an inner surface of the housing wherein the tray is decoupled from vibrations emanating from the inner surface of the housing.
USDA-ARS?s Scientific Manuscript database
Effects of treatment voltage and time of in-package atmospheric cold plasma (ACP) were studied on ozone formation, microbiological quality, surface color, and pH of fresh chicken fillets. Samples were sealed in food trays in air, treated with a dielectric-barrier-discharge (DBD) ACP system, and stor...
Helicopter Propwash Dislodges Few Spruce Budworms
Daniel T. Jennings; Mark W. Houseweart; Mark W. Houseweart
1986-01-01
Propwash treatments from a low-flying Bell 47-G2 helicopter dislodged few spruce budworm larvae and pupae from host balsam-fir trees. After propwash treatments, both larval-pupal densities on branch samples and in drop-tray collections near the ground were not significantly different between treated and control plots. Significantly more larvae were found in the lower...
Russian Extravehicular Activity (EVA) 21A EXPOSE-R
2009-03-10
ISS018-E-039227 (10 March 2009) --- One of two Expedition 18 spacewalkers on March 10 provided this close-up image of the Expose-R experiment, reinstalled a short while earlier on the outside of the Russian segment of the International Space Station. The European experiment is equipped with three trays which contain a variety of biological samples.
Russian Extravehicular Activity (EVA) 21A EXPOSE-R
2009-03-10
ISS018-E-039228 (10 March 2009) --- One of two Expedition 18 spacewalkers on March 10 provided this close-up image of the Expose-R experiment, reinstalled a short while earlier on the outside of the Russian segment of the International Space Station. The European experiment is equipped with three trays which contain a variety of biological samples.
Russian Extravehicular Activity (EVA) 21A EXPOSE-R
2009-03-10
ISS018-E-039226 (10 March 2009) --- One of two Expedition 18 spacewalkers on March 10 provided this close-up image of the Expose-R experiment, reinstalled a short while earlier on the outside of the Russian segment of the International Space Station. The European experiment is equipped with three trays which contain a variety of biological samples.
Characterization of the Protein Crystal Growth Apparatus for Microgravity Aboard the Space Station
NASA Technical Reports Server (NTRS)
Kundrot, Craig E.; Roeber, D.; Achari, A.; Stinson, Thomas N. (Technical Monitor)
2002-01-01
We have conducted experiments to determine the equilibration rates of some major precipitants used in protein crystallography aboard the International Space Station (ISS). The solutions were placed in the Protein Crystallization Apparatus for Microgravity (PCAM) which mimic Cryschem sitting drop trays. The trays were placed in cylinders. These cylinders were placed inside a Single locker Thermal Enclosure System (STES), and were activated for different durations during the flight. Bumpers pressed against elastomers seal drops in a deactivated state during pre-flight and prior to transfer to the ISS. Activation occurs while in flight on the ISS by releasing the bumpers allowing the drops to be exposed to the reservoir. PCAM was flown to the ISS on STS 100, Flight 6A, on April 19, 2001. Six series of equilibration experiments were tested for each precipitant with a small amount of Green Fluorescent Protein (GFP). Cylinder 10 was never activated, 7 was activated for 40 days, 8 was activated for 20 days, 9 was activated for 10 days, 11 was activated for 4 days and 12 was activated for 2 days. Upon the return to Earth by STS 104 on July 24,2001 the samples were transferred to Marshall Space Flight Center. The samples were then brought to the lab and the volumes of each sample were measured.
Skylab Food Heating and Serving Tray
NASA Technical Reports Server (NTRS)
1970-01-01
Shown here is the Skylab food heating and serving tray in its stowed position. The Marshall Space Flight Center had program management responsibility for the development of Skylab hardware and experiments.
A Practical Recycling Project . . .
ERIC Educational Resources Information Center
Durant, Raymond H.; Mikuska, James M.
1973-01-01
Descirbes a school district's recycling program of aluminum lunch trays that are collected after their use. The trays are used as scrap metal in industrial education workshop and used for sand castings. (PS)
Exposure to antimony from polyethylene terephthalate (PET) trays used in ready-to-eat meals.
Haldimann, M; Blanc, A; Dudler, V
2007-08-01
Antimony residues, a result of the use of a polycondensation catalyst in the production of polyethylene terephthalate (PET) oven-proof trays, were analysed in ready-to-eat meals. The toxicity of antimony has raised concerns about consumer safety; therefore, the migration of small fractions of these residues into ready meals and foods as a result of cooking directly in the PET trays was studied. A straightforward approach of measuring real samples was selected to obtain accurate exposure data. Background antimony concentration was determined separately from a series of lunch meals, which ranged from not detectable to 3.4 microg kg(-1). Microwave and conventional oven-cooking caused a distinct increase in the concentration of antimony in food and ready meals of 0-17 and 8-38 microg kg(-1), respectively, depending, to a certain extent, on the industrial preparations. The migrated quantities of antimony corresponded to 3-13 microg. For comparison, PET roasting bags and ready-made dough products in PET baking dishes were also evaluated. About half of the products prepared at a temperature of 180 degrees C exceeded the specific migration limit set for food contact material by the European Commission. However, the migrated amounts of antimony relative to the accepted tolerable daily intake (TDI) show that exposure from this type of food is currently not of toxicological concern.
Ellipsometric Analysis of Contaminant Layer on Optical Witness Samples from MISSE
NASA Technical Reports Server (NTRS)
Norwood, Joseph K.
2007-01-01
Several optical witness samples included in the Materials for International Space Station Experiment (MISSE) trays have been analyzed with a variable angle spectroscopic ellipsometer or VASE. Witness samples of gold or platinum mirrors are extremely useful as collectors of space-borne contamination, due to the relative inertness of these noble metals in the atomic oxygen-rich environment of LEO. Highly accurate thickness measurements, typically at the sub-nanometer scale, may be achieved with this method, which uses polarized light in a spectral range of 300 to 1300 nanometers at several angles of incidence to the sample surface.
1999-08-01
KENNEDY SPACE CENTER, FLA. -- An orbiter has more than 300 miles of wires such as these shown here in the cable tray inside Columbia's payload bay. During launch of Columbia on mission STS-93, a damaged wire caused a short circuit in two separate main engine controllers. As a result of the findings, Shuttle program managers have decided to conduct inspections of the wiring in Endeavour's payload bay before its next mission, STS-99. The inspection and possible repair work will lead to a delayed launch date no earlier than Oct.7. The primary payload of the mission is the Shuttle Radar Topography Mission, a specially modified radar system that will gather data for the most accurate and complete topographic map of the Earth's surface that has ever been assembled
Effect of comfort pads and incubator design on neonatal radiography.
Jiang, Xia; Baad, Michael; Reiser, Ingrid; Feinstein, Kate A; Lu, Zhengfeng
2016-01-01
There has been increasing interest in patient dose reduction in neonatal intensive care units. Removing comfort pads for radiography has been identified as a potential means to decrease patient dose. To assess the effect of comfort pads and support trays on detector entrance exposure (DEE) and image quality for neonatal radiography, and its implication for patient dose. Comfort pads and support trays from three incubator and warmer systems were examined. The attenuation of the primary beam by these structures was measured using a narrow beam geometry. Their effect on DEE and image quality was then assessed using typical neonatal chest radiography techniques with three configurations: 1) both the comfort pad and support included in the beam, 2) only the support tray included and 3) both the comfort pad and support tray removed. Comfort pads and support trays were found to attenuate the primary beam by 6-15%. Eliminating these structures from the X-ray beam's path was found to increase the detector entrance exposure by 28-36% and increase contrast-to-noise ratio by more than 21%, suggesting room for patient dose reduction when the same image quality is maintained. Comfort pads and tray support devices can have a considerable effect on DEE and image quality, with large variations among different incubator designs. Positioning the image detector directly underneath neonatal patients for radiography is a potential means for patient dose reduction. However, such benefit should be weighed against the risks of moving the patient.
MISSE 1 and 2 Tray Temperature Measurements
NASA Technical Reports Server (NTRS)
Harvey, Gale A.; Kinard, William H.
2006-01-01
The Materials International Space Station Experiment (MISSE 1 & 2) was deployed August 10,2001 and retrieved July 30,2005. This experiment is a co-operative endeavor by NASA-LaRC. NASA-GRC, NASA-MSFC, NASA-JSC, the Materials Laboratory at the Air Force Research Laboratory, and the Boeing Phantom Works. The objective of the experiment is to evaluate performance, stability, and long term survivability of materials and components planned for use by NASA and DOD on future LEO, synchronous orbit, and interplanetary space missions. Temperature is an important parameter in the evaluation of space environmental effects on materials. The MISSE 1 & 2 had autonomous temperature data loggers to measure the temperature of each of the four experiment trays. The MISSE tray-temperature data loggers have one external thermistor data channel, and a 12 bit digital converter. The MISSE experiment trays were exposed to the ISS space environment for nearly four times the nominal design lifetime for this experiment. Nevertheless, all of the data loggers provided useful temperature measurements of MISSE. The temperature measurement system has been discussed in a previous paper. This paper presents temperature measurements of MISSE payload experiment carriers (PECs) 1 and 2 experiment trays.
ERIC Educational Resources Information Center
Boss, Susan
2009-01-01
Beverage take-out trays are funky in their form and function. In this article, the author describes how to make googly eye masks out of discarded take-out trays and other common recycled or discarded materials. (Contains 1 online resource.)
77 FR 64834 - Exelon Generation Company, LLC; Oyster Creek Nuclear Generating Station; Exemption
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-23
... automatic fixed deluge water spray system installed over cable trays and open hatches. The deluge... installed over cable trays and open hatches. The deluge suppression system protecting safety- related cable...
29. VIEW OF 4TH FLOOR'S TELEPHONE RACKS WITH CABLE TRAYS ...
29. VIEW OF 4TH FLOOR'S TELEPHONE RACKS WITH CABLE TRAYS ABOVE. THESE ARE NEWER APPARATUS AND NOT ORIGINAL. - Pacific Telephone & Telegraph Company Building, 1519 Franklin Street, Oakland, Alameda County, CA
Skylab Food Heating and Serving Tray
NASA Technical Reports Server (NTRS)
1970-01-01
Shown here is the Skylab food heating and serving tray with food, drink, and utensils. The tray contained heating elements for preparing the individual food packets. The food on Skylab was a great improvement over that on earlier spaceflights. It was no longer necessary to squeeze liquified food from plastic tubes. Skylab's kitchen in the Orbital Workshop wardroom was so equipped that each crewman could select his own menu and prepare it to his own taste. The Marshall Space Flight Center had program management responsibility for the development of Skylab hardware and experiments.
Two hundred passage three-way valve: Fraction collector
NASA Technical Reports Server (NTRS)
Keffer, J. L.
1983-01-01
This paper describes the design and operation of a fraction collector used to direct flow of separated biological materials from 197 capillary tubes to either a collection tray or to a waste tank. This mechanism uses a 28-volt dc gear motor driving twin cams to force 197 needles through a self-sealing silicone rubber septum, where they inject the material in 197 separate pockets in a collection tray. The position of the collector tray is sensed by two optical limit switches. The time sequences are controlled automatically by an electronics control monitoring module.
Comparing the NIOSH Method 5040 to a Diesel Particulate Matter Meter for Elemental Carbon
NASA Astrophysics Data System (ADS)
Ayers, David Matthew
Introduction: The sampling of elemental carbon has been associated with monitoring exposures in the trucking and mining industries. Recently, in the field of engineered nanomaterials, single wall and muti-wall carbon nanotubes (MWCNTs) are being produced in ever increasing quantities. The only approved atmospheric sampling for multi-wall carbon nanotubes in NIOSH Method 5040. These results are accurate but can take up to 30 days for sample results to be received. Objectives: Compare the results of elemental carbon sampling from the NIOSH Method 5040 to a Diesel Particulate Matter (DPM) Meter. Methods: MWCNTs were transferred and weighed between several trays placed on a scale. The NIOSH Method 5040 and DPM sampling train was hung 6 inches above the receiving tray. The transferring and weighing of the MWCNTs created an aerosol containing elemental carbon. Twenty-one total samples using both meters type were collected. Results: The assumptions for a Two-Way ANOVA were violated therefore, Mann-Whitney U Tests and a Kruskal-Wallis Test were performed. The hypotheses for both research questions were rejected. There was a significant difference in the EC concentrations obtained by the NIOSH Method 5040 and the DPM meter. There were also significant differences in elemental carbon level concentrations when sampled using a DPM meter versus a sampling pump based upon the three concentration levels (low, medium and high). Conclusions: The differences in the EC concentrations were statistically significant therefore, the two methods (NIOSH Method 5040 and DPM) are not the same. The NIOSH Method 5040 should continue to be the only authorized method of establishing an EC concentration for MWCNTs until a MWCNT specific method or an instantaneous meter is invented.
Microbial composition affects the performance of an artificial Tephritid larval diet.
Rempoulakis, P; Sela Saldinger, S; Nemny-Lavy, E; Pinto, R; Birke, A; Nestel, D
2017-09-20
The present study investigated the patterns of microorganisms in an artificial larval diet during Dacus ciliatus (Diptera; Tephritidae) larval development. Microbial population contents in the diet of total heterotrophic bacteria, yeast and molds, coliform and lactobacilli, and their dynamics during development, were monitored. Initially, the microbial composition in diet trays failing to produce viable pupae and in trays successfully producing pupae and adult flies was characterized. The failing diet trays contained large populations of lactobacilli that increased during larval development, and low populations of coliforms. In contrast, the successful diet showed an increasing population of coliforms and a low, or undetected, population of lactobacilli. To study the hypothesis that lactobacilli affect D. ciliatus larval development, we conducted controlled inoculation experiments in which Lactobacillus plantarum was added into fresh diet at the time of egg seeding. L. plantarum inoculated trays showed no production of D. ciliatus. Control trays without lactobacilli inoculation showed variable results. One tray successfully produced viable pupae and adults, and showed a slight and slow increase in the indigenous populations of lactobacilli. The second tray, however, failed to produce pupae and showed a fast increase of the indigenous lactobacilli to very high levels. Monitored pH trends in L. plantarum-inoculated diet showed a sharp pH decrease during the first 4 days of larval development from 5 to less than 4 units, while successful diet, producing viable D. ciliatus pupae and adults, showed a moderate pH drop during most of the larval development period. The paper discusses the possible ecological interactions between D. ciliatus larvae, the microbial content of the diet and the physical properties of the diet. The discussion also points out at the usefulness of this approach in understanding and managing mass production parameters of tephritid fruit flies industrial diets used for Sterile Insect Technique.
2006-06-05
Space shuttle STS-121 FIT (Fly Immunity and Tumors) payload. Using Drosophila (fruit fly) to complete the experiments. Platform used by astronauts to change out old food trays with new food trays in space to facilitate culturing new flies.
Overhead tray for cable test system
NASA Technical Reports Server (NTRS)
Saltz, K. T.
1976-01-01
System consists of overhead slotted tray, series of compatible adapter cables, and automatic test set which consists of control console and cable-switching console. System reduces hookup time and also reduces cost of fabricating and storing test cables.
Corrosion inhibition for distillation apparatus
Baumert, Kenneth L.; Sagues, Alberto A.; Davis, Burtron H.; Schweighardt, Frank K.
1985-01-01
Tower material corrosion in an atmospheric or sub-atmospheric distillation tower in a coal liquefaction process is reduced or eliminated by subjecting chloride-containing tray contents to an appropriate ion-exchange resin to remove chloride from such tray contents materials.
A New Idea for Dissecting Tray
ERIC Educational Resources Information Center
Branham, Arthur
1976-01-01
A method of preparing a special dissecting tray to be used with transmitted light as well as reflected light is presented. It may also be used with an overhead projector to illustrate some skeletal structures in vertebrates. (Author/EB)
Impact of mounting methods in computerized axiography on assessment of condylar inclination.
Schierz, Oliver; Wagner, Philipp; Rauch, Angelika; Reissmann, Daniel R
2017-08-30
Valid and reliable recording is a key requirement for accurately simulating individual jaw movements. Horizontal condylar inclination (HCI) and Bennett's angle were measured using a digital jaw tracker (Cadiax® Compact 2) in 27 young adults. Three mounting methods (paraocclusal tray adapter, periocclusal tray adapter, and tray adapter with mandibular clamp) were tested. The mean values of the HCI differed by up to 10° between the mounting methods; however, the values for Bennett's angle did not differ substantially. While the intersession reliability of the Bennett's angle assessment did not depend on the mounting method, the reliability of the HCI assessment was only fair to good for the paraocclusal mounting method but poor for both periocclusal mounting methods. For attaching the tracing bow of jaw trackers to the mandible, a paraocclusal tray adapter should be applied, to achieve the most reliable results.
Amending greenroof soil with biochar to affect runoff water quantity and quality.
Beck, Deborah A; Johnson, Gwynn R; Spolek, Graig A
2011-01-01
Numbers of greenroofs in urban areas continue to grow internationally; so designing greenroof soil to reduce the amount of nutrients in the stormwater runoff from these roofs is becoming essential. This study evaluated changes in extensive greenroof water discharge quality and quantity after adding biochar, a soil amendment promoted for its ability to retain nutrients in soils and increase soil fertility. Prototype greenroof trays with and without biochar were planted with sedum or ryegrass, with barren soil trays used as controls. The greenroof trays were subjected to two sequential 7.4cm/h rainfall events using a rain simulator. Runoff from the rain events was collected and evaluated. Trays containing 7% biochar showed increased water retention and significant decreases in discharge of total nitrogen, total phosphorus, nitrate, phosphate, and organic carbon. The addition of biochar to greenroof soil improves both runoff water quality and retention. Copyright © 2011 Elsevier Ltd. All rights reserved.
A Unique Bonding Technique for Immediate Orthognathic Surgery
Ayinipully, Hariprasad; Paul, Rosaline Tina; Ponnambathayil, Shaji Aboobacker; Rasheed, Althaf Thanimoottil
2015-01-01
Introduction A challenge in orthodontics is achieving ideal bracket position which determines treatment results and finishing. A new bonding method is done indirectly on the cast and bonded directly on the teeth, but it does not require conventional trays to carry the brackets to the teeth. Materials and Methods Heavy sized archwires like 0.019″x0.025″ or 0.018″ SS are bent to the malocclusion to generate a template which comprises of an Bracket -Archwire Assembly (BAA). This assembly is transferred onto the teeth using the molar bands with tubes which serves as a jig for proper orientation of the BAA, then the adhesive is cured at one shot to complete the bonding procedure. Results Two surgical cases successfully bonded with this technique is presented in this article. Conclusion This bonding method finds specific advantages in surgical orthodontics – when the surgeon decides on a surgery-first treatment objective, management of single or a couple of periodontally extruded teeth, management of impacted teeth and in patients needing fixed functional appliance immediately before the completion of growth spurt. PMID:26266212
Accuracy of Different Implant Impression Techniques: Evaluation of New Tray Design Concept.
Liu, David Yu; Cader, Fathima Nashmie; Abduo, Jaafar; Palamara, Joseph
2017-12-29
To evaluate implant impression accuracy with a new tray design concept in comparison to nonsplinted and splinted impression techniques for a 2-implant situation. A reference bar titanium framework was fabricated to fit on 2 parallel implants. The framework was used to generate a resin master model with 2 implants that fit precisely against the framework. Three impression techniques were evaluated: (1) nonsplinted, (2) splinted, and (3) nonsplinted with modified tray impressions. All the trays were fabricated from light-cured acrylic resin material with openings that corresponded to the implant impression copings. Ten impressions were taken for each technique using poly(vinyl siloxane) impression material. The impressions were poured with type IV dental stone to generate the test casts. A rosette strain gauge was bonded to the middle of the framework. As the framework retaining screws were tightened on each test cast, the developed strains were recorded until the completion of the tightening to 35 Ncm. The generated strains of the rosette strain gauge were used to calculate the maximum principal strain. A statistically significant difference was observed among the different impression techniques. The modified tray design impression technique was associated with the least framework strains, which indicates greater accuracy compared with the other techniques. There was no significant difference between the splinted and the nonsplinted impression techniques. The new tray design concept appeared to produce more accurate implant impressions than the other techniques. Despite the statistical difference among the impression techniques, the clinical significance of this difference is yet to be determined. © 2017 by the American College of Prosthodontists.
Mutch, S J; Wentworth, S D P
2007-11-01
Modern neonatal incubators incorporate an X-ray tray device into the mattress support structure to facilitate patient examination with minimal disturbance and distress. However, the usual method of examination is to place the image plate directly underneath the baby. Users often cite radiological reasons for not using X-ray trays but modern quantitative evidence is lacking. This work looks at the technical and clinical aspects of imaging neonates in incubators and the impact that these may have in determining the imaging protocol. A number of hospitals were surveyed to determine their current method of examination and the reasons for their preference. Experimental measurements of the radiological impact of using (or not using) the X-ray tray were performed for a range of neonatal incubators. The average dose to the image plate was 5.9 microGy (range 5.4-6.4 microGy) for the "plate on mattress" method and 3.0 microGy (2.0-3.8 microGy) when using the tray--a 49% reduction owing to the mattress support materials. However, when using a computed radiography (CR) imaging system, the image quality differences were marginal. Survey results indicated that nurses preferred to use the tray but that radiographers were reluctant. We conclude that incubator manufacturers could do much to improve the radiological performance of their equipment and we offer recommendations. We also conclude that, with appropriate nurse and radiographer training and the advent of CR imaging systems, use of X-ray tray facilities may optimize imaging of the neonate in the incubator.
Three-dimensional accuracy of different impression techniques for dental implants
Nakhaei, Mohammadreza; Madani, Azam S; Moraditalab, Azizollah; Haghi, Hamidreza Rajati
2015-01-01
Background: Accurate impression making is an essential prerequisite for achieving a passive fit between the implant and the superstructure. The aim of this in vitro study was to compare the three-dimensional accuracy of open-tray and three closed-tray impression techniques. Materials and Methods: Three acrylic resin mandibular master models with four parallel implants were used: Biohorizons (BIO), Straumann tissue-level (STL), and Straumann bone-level (SBL). Forty-two putty/wash polyvinyl siloxane impressions of the models were made using open-tray and closed-tray techniques. Closed-tray impressions were made using snap-on (STL model), transfer coping (TC) (BIO model) and TC plus plastic cap (TC-Cap) (SBL model). The impressions were poured with type IV stone, and the positional accuracy of the implant analog heads in each dimension (x, y and z axes), and the linear displacement (ΔR) were evaluated using a coordinate measuring machine. Data were analyzed using ANOVA and post-hoc Tukey tests (α = 0.05). Results: The ΔR values of the snap-on technique were significantly lower than those of TC and TC-Cap techniques (P < 0.001). No significant differences were found between closed and open impression techniques for STL in Δx, Δy, Δz and ΔR values (P = 0.444, P = 0.181, P = 0.835 and P = 0.911, respectively). Conclusion: Considering the limitations of this study, the snap-on implant-level impression technique resulted in more three-dimensional accuracy than TC and TC-Cap, but it was similar to the open-tray technique. PMID:26604956
Selvaraj, Sunantha; Dorairaj, Jayachandran; Mohan, Jayashree; Simon, Paul
2016-01-01
Introduction: An accurate and passive fit of implant framework prosthesis, as well as the successful surgical operation is suggested as one of the critical requirements for long-term implant success. Objective: The purpose of this in vitro study was to evaluate the accuracy of the master cast using open tray impression technique with conventional and novel splinting materials. Methodology: A mandibular reference model with four ADIN implants was done. Ten custom trays were fabricated using the light curable resin sheets. Medium body polyether impression material was used. These trays were randomly divided between the two groups, with five trays in each group. Impression techniques were divided into two groups namely: Group A: Direct impression technique with open tray impression copings splinted with autopolymerizing acrylic resin (GC pattern resin). Group B: Direct impression technique with open tray impression copings splinted with Pro-temp TM 4 (bis-GMA) syringable temporization material. Thus, final impressions were made. Total of 10 master casts were fabricated. Evaluation of casts using Dynascope-Vision Engineering, TESA microhite two- dimension and coordinate measuring machine were used. Results: Statistical comparisons were made using ANOVA test and post-hoc test. Same amount of deviation values obtained with resin splinted and bis-GMA splinted impression copings. Conclusion: The master cast obtained by both the splinting material exhibits no difference from the reference model. So bis-GMA can be used, which is easy to handle, less time consuming, less technique sensitive, rigid, and readily available material in clinics. PMID:27141167
105. CABLE TRAY TUNNEL ENTRANCE TO LSB (BLDG. 770) AT ...
105. CABLE TRAY TUNNEL ENTRANCE TO LSB (BLDG. 770) AT SOUTH END OF LANDLINE INSTRUMENTATION ROOM - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Zhang, Dongjing; Zhang, Meichun; Wu, Yu; Gilles, Jeremie R L; Yamada, Hanano; Wu, Zhongdao; Xi, Zhiyong; Zheng, Xiaoying
2017-11-13
Standardized larval rearing units for mosquito production are essential for the establishment of a mass-rearing facility. Two larval rearing units, developed respectively by the Guangzhou Wolbaki Biotech Co. Ltd. (Wolbaki) and Insect Pest Control Laboratory, Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture (FAO/IAEA-IPCL), are tested to assess their potential uses to mass-rear the larval stages of Aedes albopictus in support of the establishment of a medium-scale mosquito facility for the application of mosquito genetic control strategies. The triple Wolbachia-infected Ae. albopictus strain (HC strain) was used in this study. The effects of larval densities of two larval rearing trays (corresponding to 2.4, 3.0 and 3.6 larvae/cm 2 ) and tray size/position (top, middle and bottom layers) on the pupae production and larval survival were assessed when trays were stacked within the larval rearing units. The male pupae production, female pupae contamination after sex separation, and male mating competitiveness were also studied by using both larval rearing units in their entirety. The optimal larval rearing density for Wolbaki-tray (Wol-tray) was 6,600 larvae (equal to 3.0 larvae/cm 2 ) and 18,000 larvae (3.6 larvae/cm 2 ) for the FAO/IAEA-IPCL tray (IAEA-tray). No significant difference in pupae production was observed when trays were stacked within top, middle or bottom layers for both units. At thirty-four hours after the first pupation, the average male pupae production was (0.89 × 10 5 ) for the Wol-unit and (3.16 × 10 5 ) for the IAEA-unit. No significant difference was observed in female pupae contamination between these two units. The HC males showed equal male mating competitiveness to wild type males for mating with wild type females in large cages, regardless of whether they were reared in the Wol-unit or IAEA-unit. The current study has indicated that both the Wol-unit and IAEA-unit are suitable for larvae mass-rearing for Ae. albopictus. However, the IAEA-unit, with higher male production and less space required compared to the Wol-unit, is recommended to be used in support of the establishment of a medium-sized mosquito facility.
Corn forage biological pretreatment by Trametes versicolor in a tray bioreactor.
Planinić, Mirela; Zelić, Bruno; Čubel, Ivan; Bucić-Kojić, Ana; Tišma, Marina
2016-08-01
Trametes versicolor is a white-rot fungus known to be efficient in lignin removal due to its complex extracellular lignocellulolytic enzymatic system. Therefore, it can be used in the treatment of lignocellulose waste from agro, food, and wood industries. In a first experiment, corn forage treatment with T. versicolor was investigated in laboratory jars. In a second experiment, the process was scaled up to a tray bioreactor. In the tray bioreactor, the process of lignin degradation was improved, resulting in an increase in lignin conversion of up to 71% during seven days' treatment. © The Author(s) 2016.
Comparative rice seed toxicity tests using filter paper, growth pouch-tm, and seed tray methods
Wang, W.
1993-01-01
Paper substrate, especially circular filter paper placed inside a Petri dish, has long been used for the plant seed toxicity test (PSTT). Although this method is simple and inexpensive, recent evidence indicates that it gives results that are significantly different from those obtained using a method that does not involve paper, especially when testing metal cations. The study compared PSTT using three methods: filter paper, Growth Pouch-TM, and seed tray. The Growth Pouch-TM is a commercially available device. The seed tray is a newly designed plastic receptacle placed inside a Petri dish. The results of the Growth Pouch-TM method showed no toxic effects on rice for Ag up to 40 mg L-1 and Cd up to 20 mg L-1. Using the seed tray method, IC50 (50% inhibitory effect concentration) values were 0.55 and 1.4 mg L-1 for Ag and Cd, respectively. Although results of filter paper and seed tray methods were nearly identical for NaF, Cr(VI), and phenol, the toxicities of cations Ag and Cd were reduced by using the filter paper method; IC50 values were 22 and 18 mg L-1, respectively. The results clearly indicate that paper substrate is not advisable for PSTT.
Continuous hydroponic wheat production using a recirculating system
NASA Technical Reports Server (NTRS)
Mackowiak, C. L.; Owens, L. P.; Hinkle, C. R.; Prince, R. P.
1989-01-01
Continuous crop production, where plants of various ages are growing simultaneously in a single recirculating nutrient solution, is a possible alternative to batch production in a Controlled Ecological Life Support System. A study was conducted at John F. Kennedy Space Center where 8 trays (0.24 sq m per tray) of Triticum aestivum L. Yecora Rojo were grown simultaneously in a growth chamber at 23 C, 65 percent relative humidity, 1000 ppm CO2, continuous light, with a continuous flow, thin film nutrient delivery system. The same modified Hoagland nutrient solution was recirculated through the plant trays from an 80 L reservoir throughout the study. It was maintained by periodic addition of water and nutrients based on chemical analyses of the solution. The study was conducted for 216 days, during which 24 trays of wheat were consecutively planted (one every 9 days), 16 of which were grown to maturity and harvested. The remaining 8 trays were harvested on day 216. Grain yields averaged 520 g m(exp -2), and had an average edible biomass of 32 percent. Consecutive yields were unaffected by nutrient solution age. It was concluded that continual wheat production will work in this system over an extended period of time. Certain micronutrient deficiencies and toxicities posed problems and must be addressed in future continuous production systems.
STS-40 Exp. No. 192 urine monitoring system (UMS) on OV-102's middeck
NASA Technical Reports Server (NTRS)
1991-01-01
STS-40 Experiment No. 192, Fluid-Electrolyte Regulation During Space Flight, urine monitoring system (UMS) is set up on the middeck of Columbia, Orbiter Vehicle (OV) 102, at the side hatch. The UMS is attached to OV-102's waste collection system (WCS). The urine specimen tray with sample tubes appears to the right of the UMS equipment.
1999-08-01
KENNEDY SPACE CENTER, FLA. -- KSC workers stand inside the payload bay of the orbiter Columbia following completion of electrical wiring inspections. In the background is the open cable tray with the wiring. During launch of Columbia on mission STS-93, a damaged wire caused a short circuit in two separate main engine controllers. As a result of the findings, Shuttle program managers decided to conduct inspections of the wiring in Endeavour's payload bay before its next mission, STS-99. The inspection and possible repair work will lead to a delayed launch date no earlier than Oct.7. The primary payload of the mission is the Shuttle Radar Topography Mission, a specially modified radar system that will gather data for the most accurate and complete topographic map of the Earth's surface that has ever been assembled
2012-04-27
CAPE CANAVERAL, Fla. – At NASA’s Kennedy Space Center in Florida, cable trays wind their way along the grating in high bay 3 in the Vehicle Assembly Building, or VAB, during part of a centerwide refurbishment initiative under the Ground Systems Development and Operations GSDO Program. The cable replacement project is under way in high bays 1 and 3 on the east side of the building, facing Launch Complex 39’s pads A and B. Approximately 150 miles of existing Apollo/shuttle era cabling is being removed to make room for installation of state-of-the-art command, communication and control systems that will be needed by future users to perform vehicle testing and verification prior to rollout to the launch pad. For more information, visit http://go.nasa.gov/groundsystems. Photo credit: NASA/Jim Grossmann
1999-08-01
KENNEDY SPACE CENTER, FLA. -- KSC workers stand inside the payload bay of the orbiter Columbia following completion of electrical wiring inspections. At right, behind and below them is the cable tray with the wiring. During launch of Columbia on mission STS-93, a damaged wire caused a short circuit in two separate main engine controllers. As a result of the findings, Shuttle program managers decided to conduct inspections of the wiring in Endeavour's payload bay before its next mission, STS-99. The inspection and possible repair work will lead to a delayed launch date no earlier than Oct.7. The primary payload of the mission is the Shuttle Radar Topography Mission, a specially modified radar system that will gather data for the most accurate and complete topographic map of the Earth's surface that has ever been assembled
2012-04-27
CAPE CANAVERAL, Fla. – At NASA’s Kennedy Space Center in Florida, cable trays run along the walls in high bay 3 in the Vehicle Assembly Building, or VAB, as part of a centerwide refurbishment initiative under the Ground Systems Development and Operations GSDO Program. The cable replacement project is under way in high bays 1 and 3 on the east side of the building, facing Launch Complex 39’s pads A and B. Approximately 150 miles of existing Apollo/shuttle era cabling is being removed to make room for installation of state-of-the-art command, communication and control systems that will be needed by future users to perform vehicle testing and verification prior to rollout to the launch pad. For more information, visit http://go.nasa.gov/groundsystems. Photo credit: NASA/Jim Grossmann
7 CFR 457.162 - Nursery crop insurance provisions.
Code of Federal Regulations, 2011 CFR
2011-01-01
... inch in diameter (including trays containing 200 or fewer individual cells, unless specifically... or cell interior, have an established root system, and meet all other conditions specified in the... container interior (including trays that contain 200 or fewer individual cells, unless specifically provided...
7 CFR 457.162 - Nursery crop insurance provisions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... inch in diameter (including trays containing 200 or fewer individual cells, unless specifically... or cell interior, have an established root system, and meet all other conditions specified in the... container interior (including trays that contain 200 or fewer individual cells, unless specifically provided...
7 CFR 457.162 - Nursery crop insurance provisions.
Code of Federal Regulations, 2013 CFR
2013-01-01
... inch in diameter (including trays containing 200 or fewer individual cells, unless specifically... or cell interior, have an established root system, and meet all other conditions specified in the... container interior (including trays that contain 200 or fewer individual cells, unless specifically provided...
7 CFR 457.162 - Nursery crop insurance provisions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... inch in diameter (including trays containing 200 or fewer individual cells, unless specifically... or cell interior, have an established root system, and meet all other conditions specified in the... container interior (including trays that contain 200 or fewer individual cells, unless specifically provided...
Rios, M P; Morgano, S M; Stein, R S; Rose, L
1996-10-01
Currently available impression materials were not designed for disinfection or sterilization, and it is conceivable that disinfectants may adversely affect impressions. This study evaluated the accuracy and dimensional stability of polyether (Permadyne/Impregum) and polyvinyl siloxane (Express) impression materials retained by their adhesives in two different acrylic resin tray designs (perforated and nonperforated) when the materials were immersed for either 30 or 60 minutes in three high-level disinfectants. Distilled water and no solution served as controls. A stainless steel test analog similar to ADA specification No. 19 was used. A total of 400 impressions were made with all combinations of impression materials, tray designs, disinfectant, and soaking times. Samples were evaluated microscopically before and after immersion and 48 hours after soaking. Results indicated that these two impression materials were dimensionally stable. Because the results emphasized the stability and accuracy of the impression complex under various conditions, dentists can perform disinfection procedures similar to the protocol of this study without concern for clinically significant distortion of the impression.
Stark, Jonathan S; Johnstone, Glenn J; Riddle, Martin J
2014-12-15
A shoreline waste disposal site at Casey Station, Antarctica was removed because it was causing impacts in the adjacent marine environment (Brown Bay). We conducted a field experiment to determine whether the excavation created further impacts. Trays of clean, defaunated sediment were deployed at two locations within Brown Bay and two control locations, two years prior to remediation. Trays were sampled one year before, 1month before, 1month after and two years after the excavation. An increase in metals was found at Brown Bay two years after the remediation. However there was little evidence of impacts on sediment assemblages. Communities at each location were different, but differences from before to after the remediation were comparable, indicating there were unlikely to have been further impacts. We demonstrate that abandoned waste disposal sites in hydrologically active places in Antarctica can be removed without creating greater adverse impacts to ecosystems downstream. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.
Panseri, S; Martino, P A; Cagnardi, P; Celano, G; Tedesco, D; Castrica, M; Balzaretti, C; Chiesa, L M
2018-05-30
This study was designated to ascertain the effectiveness of polylactic acid (PLA) based packaging solution to store red fresh meat during its refrigerated shelf-life. Recently the attention in the packaging industry regarding the use of bioplastics has been shifting from compostable/biodegradable materials toward biobased materials. Steaks obtained from semimembranous muscle of Piemontese beef were packaged in PLA trays closed with a lid made of PLA film and for comparison purposed in a conventional reference package consisting of a amorphous polyethylene terephthalate/polyethylene (APET/PET) trays and wrapped in plastic film of polyvinyl chloride (PVC). The packaging under modified atmosphere MAP was carried out by using a gas mixture of 66% O 2 , 25% CO 2 and 9%N 2 . By using PLA packaging combination it was possible to maintain an optimum red colour together with a reduced content of volatile compounds associated to off-flavours of meat samples particularly related to the oxidation phenomena. Copyright © 2017 Elsevier Ltd. All rights reserved.
Reduction and standardization of surgical instruments in pediatric inguinal hernia repair.
Koyle, Martin A; AlQarni, Naif; Odeh, Rakan; Butt, Hissan; Alkahtani, Mohammed M; Konstant, Louis; Pendergast, Lisa; Koyle, Leah C C; Baker, G Ross
2018-02-01
To standardize and reduce surgical instrumentation by >25% within a 9-month period for pediatric inguinal hernia repair (PIHR), using "improvement science" methodology. We prospectively evaluated instruments used for PIHR in 56 consecutive cases by individual surgeons across two separate subspecialties, pediatric surgery (S) and pediatric urology (U), to measure actual number of instruments used compared with existing practice based on preference cards. Based on this evaluation, a single preference card was developed using only instruments that had been used in >50% of all cases. A subsequent series of 52 cases was analyzed to assess whether the new tray contained the ideal instrumentation. Cycle time (CT), to sterilize and package the instruments, and weights of the trays were measured before and after the intervention. A survey of operating room (OR) nurses and U and S surgeons was conducted before and after the introduction of the standardized tray to assess the impact and perception of standardization. Prior to creating the standardized tray, a U PIHR tray contained 96 instruments with a weight of 13.5 lbs, while the S set contained 51, weighing 11.2 lbs. The final standardized set comprised 28 instruments and weighed 7.8 lbs. Of 52 PIHRs performed after standardization, in three (6%) instances additional instruments were requested. CT was reduced from 11 to 8 min (U and S respectively) to <5 min for the single tray. Nurses and surgeons reported that quality, safety, and efficiency were improved, and that efforts should continue to standardize instrumentation for other common surgeries. Standardization of surgical equipment can be employed across disciplines with the potential to reduce costs and positively impact quality, safety, and efficiencies. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Gaillard, Romain; Cerciello, Simone; Lustig, Sebastien; Servien, Elvire; Neyret, Philippe
2017-04-01
Total knee arthroplasty (TKA) malalignment may result in pain and limited range of motion. The present study assessed the influence of different surgeon's and patient's related factors on the post-operative tibial tray coronal alignment. The charts and the x-rays of a continuous prospective series of 1417 TKAs operated upon between 1987 and 2015 were retrospectively reviewed. The long-leg AP views were performed at two months post-op and the tibial mechanical angle of the tibial tray was measured. Three groups were defined: varus (≤87° n = 167), valgus (≥93° n = 55) and well alignment (88° to 92° n = 1195). The influence of several pre-operative and peri-operative factors was investigated: surgeon handedness and experience (junior or senior), previous tibial osteotomies, Ahlbäck stage of osteoarthritits, pre-operative alignment, height and weight, age at surgery, approach (medial, lateral or tibial tubercle osteotomy), generation of implants, tray fixation, size of the tray and stem lenght. Univariate then multivariate analysis were performed to find out any correlation. Multivariate analysis showed a strong correlation between varus alignment of the tibial tray and pre-operative varus of the lower limb (p = 0.037), increased BMI (p = 0.016) and operated side opposite to the dominant surgeon's arm (p = 0.006). In a similar way a strong correlation was found between valgus alignment and pre-operative valgus of the limb (p = 0.026). Poor alignment of the tibial tray after TKA was associated with pre-operative malalignment of the lower limb, increased BMI and an index knee which was opposite to surgeon's dominant arm.
Validation of a New Larval Rearing Unit for Aedes albopictus (Diptera: Culicidae) Mass Rearing
Gilles, Jérémie R. L.; Bellini, Romeo
2014-01-01
The mosquito larval rearing unit developed at the Insect Pest Control Laboratory (IPCL) of the FAO/IAEA Joint Division was evaluated for its potential use for Aedes albopictus (Skuse, 1895) mass rearing in support of the development of a sterile insect technique (SIT) package for this species. The use of the mass rearing trays and rack did not adversely affect larval development, pupation and survival rates and allowed the management of large larval rearing colonies with reduced space requirements in comparison with classical individual trays. The effects of larval density, water temperature and diet composition on pupal production and size differentiation for sex separation efficacy were analyzed for individual mass rearing trays as well as multiple trays stacked within the dedicated rack unit. Best results were obtained using eighteen thousand larvae per tray at a density of 3 larvae per ml of deionized water at a temperature of 28°C on a diet consisting of 50% tuna meal, 36% bovine liver powder, 14% brewer's yeast and, as an additive, 0.2 gr of Vitamin Mix per 100 ml of diet solution. Pupae were harvested on the sixth day from larval introduction at L1 stage and males were separated out by the use of a 1400 µm sieve with 99.0% accuracy with a recovery rate of ca. 25% of the total available males. With the use of this larval rearing unit, an average production of 100,000 male pupae per week can be achieved in just 2 square meter of laboratory space. Compared to previous laboratory rearing method, the same pupal production and sex separation efficacy could only be achieved by use of ca. 200 plastic trays which required the space of two 5 square meter climatic-controlled rooms. PMID:24647347
5. VIEW OF CABLE SHED AND CABLE TRAY EMANATING FROM ...
5. VIEW OF CABLE SHED AND CABLE TRAY EMANATING FROM SOUTH FACE OF LAUNCH OPERATIONS BUILDING. MICROWAVE DISH IN FOREGROUND. METEOROLOGICAL TOWER IN BACKGROUND. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Sumita, Yuka I; Hattori, Mariko; Elbashti, Mahmoud E; Taniguchi, Hisashi
2017-05-01
This clinical technique provides a key procedure for successful prosthetic treatment in patients with an anatomical compromise after a maxillectomy. When making a preliminary impression, the clinician must keep the handle of the stock tray parallel to the patient's interpupillary line extraorally to maintain the correct position of the tray and to make a record of the inclination of the occlusal plane. This simple consideration during this first step of making a preliminary impression can be an important guide for both dentists and dental technicians. Information about the correct positioning of the tray and the inclination of the occlusal plane obtained by using a stock tray handle will greatly reduce the stress experienced by dentists, dental technicians, and patients during the fabrication of the prosthesis and will ultimately lead to successful prosthetic treatment in patients with anatomic compromise resulting from a maxillectomy. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Observation of Gigawatt-Class THz Pulses from a Compact Laser-Driven Particle Accelerator
NASA Astrophysics Data System (ADS)
Gopal, A.; Herzer, S.; Schmidt, A.; Singh, P.; Reinhard, A.; Ziegler, W.; Brömmel, D.; Karmakar, A.; Gibbon, P.; Dillner, U.; May, T.; Meyer, H.-G.; Paulus, G. G.
2013-08-01
We report the observation of subpicosecond terahertz (T-ray) pulses with energies ≥460μJ from a laser-driven ion accelerator, thus rendering the peak power of the source higher even than that of state-of-the-art synchrotrons. Experiments were performed with intense laser pulses (up to 5×1019W/cm2) to irradiate thin metal foil targets. Ion spectra measured simultaneously showed a square law dependence of the T-ray yield on particle number. Two-dimensional particle-in-cell simulations show the presence of transient currents at the target rear surface which could be responsible for the strong T-ray emission.
Challenges to validation of a complex nonsterile medical device tray.
Prince, Daniel; Mastej, Jozef; Hoverman, Isabel; Chatterjee, Raja; Easton, Diana; Behzad, Daniela
2014-01-01
Validation by steam sterilization of reusable medical devices requires careful attention to many parameters that directly influence whether or not complete sterilization occurs. Complex implant/instrument tray systems have a variety of configurations and components. Geobacillus stearothermophilus biological indicators (BIs) are used in overkill cycles to to simulate worst case conditions and are intended to provide substantial sterilization assurance. Survival of G. stearothermophilus spores was linked to steam access and size of load in the chamber. By a small and reproducible margin, it was determined that placement of the trays in a rigid container into minimally loaded chambers were more difficult to completely sterilize than maximally loaded chambers.
ERIC Educational Resources Information Center
Mitchell, Annette W.
2005-01-01
Foam printing offers all ages and abilities a way to explore textures in the classroom and to develop personal creativity and imagination. Polystyrene foam trays (commonly known as "meat trays") are readily available, inexpensive, lightweight, portable, and receptive to a wide variety of surface treatments. The printmaking process requires only a…
Hanks, Andrew S; Wansink, Brian; Just, David R
2014-03-01
Measuring food waste is essential to determine the impact of school interventions on what children eat. There are multiple methods used for measuring food waste, yet it is unclear which method is most appropriate in large-scale interventions with restricted resources. This study examines which of three visual tray waste measurement methods is most reliable, accurate, and cost-effective compared with the gold standard of individually weighing leftovers. School cafeteria researchers used the following three visual methods to capture tray waste in addition to actual food waste weights for 197 lunch trays: the quarter-waste method, the half-waste method, and the photograph method. Inter-rater and inter-method reliability were highest for on-site visual methods (0.90 for the quarter-waste method and 0.83 for the half-waste method) and lowest for the photograph method (0.48). This low reliability is partially due to the inability of photographs to determine whether packaged items (such as milk or yogurt) are empty or full. In sum, the quarter-waste method was the most appropriate for calculating accurate amounts of tray waste, and the photograph method might be appropriate if researchers only wish to detect significant differences in waste or consumption of selected, unpackaged food. Copyright © 2014 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.
4. VIEW OF CABLE SHED AND CABLE TRAY EMANATING FROM ...
4. VIEW OF CABLE SHED AND CABLE TRAY EMANATING FROM NORTH FACE OF LAUNCH OPERATIONS BUILDING. TOPS OF BUNKER PERISCOPE AND FLAGPOLE ON ROOF OF LAUNCH OPERATIONS BUILDING IN BACKGROUND - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
ERIC Educational Resources Information Center
Monakes, Sarah; Garza, Yvonne; Wiesner, Van, III; Watts, Richard E.
2011-01-01
The purpose of this phenomenological study was to understand the perceptions of adult male substance offenders who experienced sand tray therapy as an adjunct to their cognitive behavioral rehabilitative treatment. Results indicate a positive experience for participants. Implications for counselors are discussed. (Contains 1 table.)
40. Coffee bean drying trays that are stored in racks ...
40. Coffee bean drying trays that are stored in racks under building and pulled out to sun dry beans on terraces to the north and south of building. HAER PR, 6-MAGU, 1C-3 - Hacienda Buena Vista, PR Route 10 (Ponce to Arecibo), Magueyes, Ponce Municipio, PR
77 FR 63771 - Implementation of Full-Service Intelligent Mail Requirements for Automation Prices
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-17
... tray barcodes (IMtb) on trays, tubs, and sacks; apply unique Intelligent Mail container barcodes (IMcb) on placards for containers, such as pallets; schedule appointments through Facility Access and... preparation of mail, which provides high-value services and enables efficient mail processing. The strategic...
Training to Increase Safe Tray Carrying among Cocktail Servers
ERIC Educational Resources Information Center
Scherrer, Megan D.; Wilder, David A.
2008-01-01
We evaluated the effects of training on proper carrying techniques among 3 cocktail servers to increase safe tray carrying on the job and reduce participants' risk of developing musculoskeletal disorders. As participants delivered drinks to their tables, their finger, arm, and neck positions were observed and recorded. Each participant received…
Closeup of LDEF experiment trays documented during STS-32 photo survey
1990-01-20
Closeup of Long Duration Exposure Facility (LDEF) experiment trays is documented during STS-32 retrieval activity and photo survey conducted by crewmembers onboard Columbia, Orbiter Vehicle (OV) 102. Partially visible is the Polymer Matrix Composite Materials Experiment. In the background is the surface of the Earth.
Planetary Protection Plan for an Antibody based instrument proposed for Mars2020
NASA Astrophysics Data System (ADS)
Smith, Heather; Parro, Víctor
The Signs Of Life Detector (SOLID) instrument is a high TRL level instrument proposed for the Mars 2020 instrument suite. In this presentation we describe the planetary protection instrument plan as if the instrument is classified as a life detection instrument compliant with Category IV(b) planetary protection mission requirements, NASA, ESA, and COSPAR policy. SOLID uses antibodies as a method for detecting organic and biomolecular components in soils. Due to the sensitive detection method, the scientific integrity of the instrument exceeds the planetary protection requirements. The instrument will be assembled and integrated in an ISO level 8 cleanroom or better (ISO 4 for the sample read out and fluidics components). Microbial reduction methods and assays employed are as follows: Wipe the outside and inside of the instrument with a mixture of isopropyl alcohol (70%) and water. Cell cultures will be the standard assay to determine enumeration of “viable” spores and other rapid assays such as LAL and ATP bioluminescence as secondary assays to verify the interior of the instrument is microbe free. SOLID’s design factors for contamination control include the following features: SOLID has the capability to heat the catchment tray to pyrolyze any Earth hitchhikers. There will also be an “air gap” of cm maintained between the sample acquisition device and the funnel inlet. This will prevent forward contamination of the sample collection device and reverse contamination of the detection unit. To mitigate false positives, SOLID will include anti-bodies for potential contaminants from organisms most commonly found in clean rooms. If selected for the Mars 2020 Rover, SOLID would be the first life detection instrument based on biomolecules sent by NASA, as such the planetary protection plan will set a precedence for future life detection instruments carrying biomolecules to other planetary bodies.
NASA Technical Reports Server (NTRS)
Walker, Bruce E.; Panda, Jayanta; Sutliff, Daniel L.
2008-01-01
External Tank Cable Tray vibration data for three successive Space Shuttle flights were analyzed to assess response to buffet and the effect of removal of the Protuberance Air Loads (PAL) ramp. Waveform integration, spectral analysis, cross-correlation analysis and wavelet analysis were employed to estimate vibration modes and temporal development of vibration motion from a sparse array of accelerometers and an on-board system that acquired 16 channels of data for approximately the first 2 min of each flight. The flight data indicated that PAL ramp removal had minimal effect on the fluctuating loads on the cable tray. The measured vibration frequencies and modes agreed well with predicted structural response.
NASA Technical Reports Server (NTRS)
Walker, B. E.; Panda, B. E.; Sutliff, D. L.
2008-01-01
External Tank Cable Tray vibration data for three successive Space Shuttle flights were analyzed to assess response to buffet and the effect of removal of the Protuberance Air Loads (PAL) ramp. Waveform integration, spectral analysis, cross-correlation analysis and wavelet analysis were employed to estimate vibration modes and temporal development of vibration motion from a sparse array of accelerometers and an on-board system that acquired 16 channels of data for approximately the first two minutes of each flight. The flight data indicated that PAL ramp removal had minimal effect on the fluctuating loads on the cable tray. The measured vibration frequencies and modes agreed well with predicted structural response.
STS-57 inflight maintenance (IFM) tool tray at Boeing FEPF bench review
NASA Technical Reports Server (NTRS)
1993-01-01
STS-57 inflight maintenance (IFM) tool tray is displayed on a table top during the bench review at Boeing's Flight Equipment Processing Facility (FEPF) located near JSC. The tool tray will be located on Endeavour's, Orbiter Vehicle (OV) 105's, middeck in forward locker MF57K and includes modified forceps, L-shaped hex wrenches, jeweler screwdrivers, adjustable wrench, bone saw, combination wrenches, override devices, switch guards, tape measure, torque driver, short screwdriver, long screwdriver, phillips screwdrivers, ratchet wrench, needlenose pliers, torque tips, adapter, universal joint, deepwell sockets, sockets, driver handle, seat adjustment tool, extensions, torque wrench, allen head drivers, hacksaw, and blades. Photo taken by NASA JSC contract photographer Benny Benavides.
Exposure of LDEF materials to atomic oxygen: Results of EOIM 3
NASA Technical Reports Server (NTRS)
Jaggers, C. H.; Meshishnek, M. J.
1995-01-01
The third Effects of Oxygen Atom Interaction with Materials (EOIM 3) experiment flew on STS-46 from July 31 to August 8, 1992. The EOIM-3 sample tray was exposed to the low-earth orbit space environment for 58.55 hours at an altitude of 124 nautical miles resulting in a calculated total atomic oxygen (AO) fluence of 1.99 x 10(exp 20) atoms/sq cm. Five samples previously flown on the Long Duration Exposure Facility (LDEF) Experiment M0003 were included on the Aerospace EOIM 3 experimental tray: (1) Chemglaze A276 white thermal control paint from the LDEF trailing edge (TE); (2) S13GLO white thermal control paint from the LDEF TE; (3) S13GLO from the LDEF leading edge (LE) with a visible contamination layer from the LDEF mission; (4) Z306 black thermal control paint from the LDEF TE with a contamination layer from the LDEF mission; and (5) anodized aluminum from the LDEF TE with a contamination layer from the LDEF mission. The purpose of this experiment was twofold: (l) investigate the response of trailing edge LDEF materials to atomic oxygen exposure, thereby simulating LDEF leading edge phenomena; (2) investigate the response of contaminated LDEF samples to atomic oxygen in attempts to understand LDEF contamination-atomic oxygen interactions. This paper describes the response of these materials to atomic oxygen exposure, and compares the results of the EOIM 3 experiment to the LDEF mission and to ground-based atomic oxygen exposure studies.
Mittleman, D M; Hunsche, S; Boivin, L; Nuss, M C
1997-06-15
We demonstrate tomographic T-ray imaging, using the timing information present in terahertz (THz) pulses in a reflection geometry. THz pulses are reflected from refractive-index discontinuities inside an object, and the time delays of these pulses are used to determine the positions of the discontinuities along the propagation direction. In this fashion a tomographic image can be constructed.
USDA-ARS?s Scientific Manuscript database
Binucleate Rhizoctonia fungi cause web blight on azaleas and other woody ornamental plants. This research focused on one aspect of how the pathogen may spread from contaminated floors of propagation houses into trays containing clean azalea stem cuttings that generate new root systems. Rhizoctonia w...
75 FR 32143 - Submission of Electronic Documentation With Comailed and Copalletized Mailings
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-07
... efficiency in the processing of copalletized mailings. The Postal Service can accept piece-level electronic...-size pieces in trays, which include pieces to be incorporated within a copalletized mailing, to prepare... statements for payment at the consolidator site. Consolidators of letter-size pieces in trays will also be...
Machine Cleans And Degreases Without Toxic Solvents
NASA Technical Reports Server (NTRS)
Gurguis, Kamal S.; Higginson, Gregory A.
1993-01-01
Appliance uses hot water and biodegradable chemicals to degrease and clean hardware. Spray chamber essentially industrial-scale dishwasher. Front door tilts open, and hardware to be cleaned placed on basket-like tray. During cleaning process, basket-like tray rotates as high-pressure "V" jets deliver steam, hot water, detergent solution, and rust inhibitor as required.
NASA Technical Reports Server (NTRS)
Colborn, B. L.; Armstrong, T. W.
1992-01-01
A computer model of the three dimensional geometry and material distributions for the LDEF spacecraft, experiment trays, and, for selected trays, the components of experiments within a tray was developed for use in ionizing radiation assessments. The model is being applied to provide 3-D shielding distributions around radiation dosimeters to aid in data interpretation, particularly in assessing the directional properties of the radiation exposure. Also, the model has been interfaced with radiation transport codes for 3-D dosimetry response predictions and for calculations related to determining the accuracy of trapped proton and cosmic ray environment models. The methodology is described used in developing the 3-D LDEF model and the level of detail incorporated. Currently, the trays modeled in detail are F2, F8, and H12 and H3. Applications of the model which are discussed include the 3-D shielding distributions around various dosimeters, the influence of shielding on dosimetry responses, and comparisons of dose predictions based on the present 3-D model vs those from 1-D geometry model approximations used in initial estimates.
Patch testing custom isocyanate materials from the workplace.
Burrows, Dianne; Houle, Marie-Claude; Holness, D Linn; DeKoven, Joel; Skotnicki, Sandy
2015-01-01
Patch testing with standard trays of commercially available allergens is the current practice for investigating suspected cases of isocyanate-induced allergic contact dermatitis (ACD). In some facilities, these standard trays are further supplemented with custom preparations of isocyanate-containing materials. The aim was to determine whether added value exists in patch testing patients to custom isocyanate preparations in suspected cases of ACD. We performed a retrospective analysis of 11 patients referred to our specialty clinic between January 2003 and March 2011 for suspected patients of ACD who had custom testing with isocyanate materials from their workplace. In addition to standard trays of allergens, all patients were patch tested with custom isocyanate materials from their workplaces. Three (27%) of 11 patients showed an added value in testing to custom isocyanate allergens. Of these 3 patients, one had a reaction that reinforced positive reactions to the standard isocyanate tray, but the other 2 (18%) had no reactions to any of the commercially available allergens. Because of the high proportion of reactions (27%), we recommend the use of custom testing to workplace isocyanate products as a supplement to current standard patch testing procedures.
2012-04-27
CAPE CANAVERAL, Fla. – At NASA’s Kennedy Space Center in Florida, cable is being pulled from the cable trays lining the walls of high bay 3 in the Vehicle Assembly Building, or VAB, as part of a centerwide refurbishment initiative under the Ground Systems Development and Operations GSDO Program. The cable replacement project is under way in high bays 1 and 3 on the east side of the building, facing Launch Complex 39’s pads A and B. Approximately 150 miles of existing Apollo/shuttle era cabling is being removed to make room for installation of state-of-the-art command, communication and control systems that will be needed by future users to perform vehicle testing and verification prior to rollout to the launch pad. For more information, visit http://go.nasa.gov/groundsystems. Photo credit: NASA/Jim Grossmann
Kaneko, Takahiro; Yamagishi, Kiyoshi; Horie, Norio; Shimoyama, Tetsuo
2013-01-01
To evaluate the clinical outcome of a novel open-tray impression technique for fabrication of a provisional prosthesis supported by immediately loaded implants in a completely edentulous arch. An open-tray impression technique was evaluated in this retrospective study that included patients treated between March 2006 and October 2009. Preoperatively, a diagnostic prosthesis was delivered, and a novel open tray was fabricated based on this prosthesis. After implant placement, the impression and interocclusal record were taken simultaneously using the novel open tray. Laboratory-fabricated, screw-retained, all-acrylic resin provisional restorations were delivered on the same day of surgery. The prosthesis was assessed from the day of surgery until replacement with a definitive prosthesis. The study included 21 patients (mean age, 64.5 years) and a total of 125 implants. Of these, 104 implants were immediately loaded. In all patients, well-fitting provisional restorations supported by a minimum of four implants were delivered. Fracture of the first molar cusp was observed in one case after 30 days. However, there was no extensive fracture in the framework or functional disorder of the prosthesis. No implant failed during the follow-up after implant surgery. This protocol enabled fabrication of a well-fitting acrylic resin provisional prosthesis supported by immediately loaded implants because the impression was taken while in centric occlusion and an occlusion identical to the diagnostic prosthesis could be reconstructed.
ERIC Educational Resources Information Center
Connors, Priscilla; Bednar, Carolyn
2015-01-01
Purpose/Objectives: The study objective was to document choices of entrées, vegetables, fruits, grains/breads, and beverages on lunch trays and to determine the amount of each that was discarded after mealtime. Methods: A convenience sample of two urban middle school cafeterias in Texas participated in the study which took place in the 2010-2011…
1988-10-24
Mission Specialist George (Pinky) D. Nelson uses a 35 mm camera to photograph a protein crystal grown during the STS-26 Protein Crystal Growth (PCG-II-01) experiment. The protein crystal growth (PCG) carrier is shown deployed from the PCG Refrigerator/Incubator Mocule (R/IM) located in the middeck forward locker. The R/IM contained three Vapor Diffusion Apparatus (VDS) trays (one of which is shown). A total of sixty protein crystal samples were processed during the STS-26 mission.
Beta Vulgaris and Easter Egg Radish Growth in Varying Mediums and Locations
NASA Astrophysics Data System (ADS)
Brittingham, P.; Figueroa, A.
2016-12-01
The purpose of this experiment is to study the harvest yield and taste of Beta Vulgaris and Easter Egg Radish microgreens in different growing mediums and locations at the Stanford Farm. They are grown in three different mediums: compost, potting mix, and a 50/50 mix of both. We hypothesized that the even mixture of compost and potting mix would have a larger harvest yield and greater nutrient content while being grown in the lath house. The experiment begins with two sets of three planting trays, one in the greenhouse and one in the lath house, filled with the former growing mediums. Next, the seeds of the microgreens are sprinkled evenly in their designated halves of the tray, then covered with a thin layer of their growing medium to allow for germination. The trays in the lath house are watered 1-2 times a day while the greenhouse trays must be watered thrice. The progress of the microgreens are observed everyday and the weight, height, root length and width of the plant is measured. Once harvested, 9-11 days after planting, the microgreens are weighed and tested for taste and consistency. Because each microgreen variety is planted in only half of a tray, the weight of the full tray is calculated to estimate the value and yield of a single species on a larger scale. Upon collecting data from both the lath house and greenhouse, we found that the plants perform better in the 50/50 mixture and potting mix, but grow very poorly in the compost because it requires a lot of water and does not hold the moisture it receives. We also had a higher yield of Easter Egg Radish due to its height and water content. In the greenhouse, both species had a richer flavor. The farm plans to start a microgreen business to provide an added source of income and utilize the results of this experiment in an applied business model focused on efficiency and profit.
Spread potential of binucleate Rhizoctonia from propagation floors to trays containing stem cuttings
USDA-ARS?s Scientific Manuscript database
Binucelate Rhizoctonia spp. (BNR), the cause of web blight, are present all year on container-grown azaleas in the southern U.S. BNR can be eliminated during vegetative propagation by submerging stem cuttings in 50°C water for 21 minutes. The objective was to evaluate risk of rooting trays bein...
ERIC Educational Resources Information Center
Hancock's, Matthew
2012-01-01
In the "Adults Learning" autumn issue, the journal staff asked key players in the learning and skills sector what they thought should be at the top of new skills minister Matthew Hancock's in-tray. The new minister shares that his job in the further education and skills sector is to rise to the challenge and play his full part in giving…
Robotic Vision, Tray-Picking System Design Using Multiple, Optical Matched Filters
NASA Astrophysics Data System (ADS)
Leib, Kenneth G.; Mendelsohn, Jay C.; Grieve, Philip G.
1986-10-01
The optical correlator is applied to a robotic vision, tray-picking problem. Complex matched filters (MFs) are designed to provide sufficient optical memory for accepting any orientation of the desired part, and a multiple holographic lens (MHL) is used to increase the memory for continuous coverage. It is shown that with appropriate thresholding a small part can be selected using optical matched filters. A number of criteria are presented for optimizing the vision system. Two of the part-filled trays that Mendelsohn used are considered in this paper which is the analog (optical) expansion of his paper. Our view in this paper is that of the optical correlator as a cueing device for subsequent, finer vision techniques.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barna, B.A.; Ginn, R.F.
1985-05-01
In computer programs which perform shortcut calculations for multicomponent distillation, the Gilliland correlation continues to be used even though errors of up to 60% (compared with rigorous plate-to-plate calculations) were shown by Erbar and Maddox. Average absolute differences were approximately 30% for Gilliland's correlation versus 4% for the Erbar-Maddox method. The reason the Gilliland correlation continues to be used appears to be due to the availability of an equation by Eduljee which facilitates the correlation's use in computer program. A new equation is presented in this paper that represents the Erbar-Maddox correlation of trays with reflux for multicomponent distillation. Atmore » low reflux ratios, results show more trays are needed than would be estimated by Gilliland's method.« less
Garcia-Fernandez, Juan; Garcia-Molina, Alberto; Aparicio-Lopez, Celeste; Sanchez-Carrion, Rocío; Ensenat, Antònia; Pena-Casanova, Jordi; Roig-Rovira, Teresa
2015-12-16
Tham and Tegner proposed the Baking Tray Task (BTT) as a fast simple assessment test for detecting spatial negligence. However, very few studies have examined its validity as a diagnostic test. To analyse the diagnostic validity of the BTT by measuring its specificity and sensitivity in a sample of subjects with right hemisphere strokes. Forty-eight patients with right hemisphere vascular lesions were distributed in two groups (negligence group, n = 35; non-negligence group, n = 13) according to the scores obtained in a battery of visuospatial examination tests. The participants' performance on the BTT was compared with that of a healthy control group (n = 12). The results showed a high level of sensitivity of the BTT, but low specificity. The performance on the BTT of eight of the 13 members of the non-negligence group was suggestive of negligence. The BTT has proved to be a sensitive test for the detection of spatial negligence. Yet, based on its low specificity, its use alone as a single diagnostic test is not recommended.
Abrol, Surbhi; Nagpal, Archana; Kaur, Rupandeep; Verma, Ramit; Katna, Vishal; Gupt, Parikshit
2017-08-01
Minor rotation of impression coping secured in the impression is an avoidable error that needs to be minimized to ensure precise positioning of implant analog in master cast. The aim of the study was to compare the precision in obtaining master casts by improving the stability of impression copings in the impression with the use of tray adhesive along various surface treatments to increase surface area and by mechanical locking. A total of 60 samples were made (15 samples for each group). A total of 15 samples for Group I were prepared with untreated impression copings, 15 samples for Group II with impression copings treated and modified by application of tray adhesive only. Group III includes 15 samples which were fabricated with impression copings modified by making four vertical grooves on surface of impression coping and coated with adhesive. Group IV had 15 samples which were fabricated with impression copings sandblasted with 50 μm aluminum oxide powder and coated with adhesive. Profile projector was used to evaluate the rotational accuracy of the implant analogs by comparing Molar Implant Angle (MIA) and Premolar Implant Angle (PIA) of test samples with reference model. One-way ANOVA and Student t-test were used to analyze the data. One-way ANOVA didn't show any significant differences for both MIA and PIA between the Groups I, II, III and IV. Student's unpaired t-test revealed no significant difference in the mean MIA and mean PIA. Conclusion: Though results were statistically non-significant, all types of surface treatments of the impression copings showed more accurate transfer than those with no treatment. Sandblasted and adhesive coated impression copings showed minimum amount of rotation followed by those with vertical slots and adhesive coated impression copings.
Melli, Virginia; Juszczyk, Mateusz; Sandrini, Enrico; Bolelli, Giovanni; Bonferroni, Benedetta; Lusvarghi, Luca; Cigada, Alberto; Manfredini, Tiziano; De Nardo, Luigi
2015-01-01
The increasing number of total joint replacements, in particular for the knee joint, has a growing impact on the healthcare system costs. New cost-saving manufacturing technologies are being explored nowadays. Metal injection molding (MIM) has already demonstrated its suitability for the production of CoCrMo alloy tibial trays, with a significant reduction in production costs, by holding both corrosion resistance and biocompatibility. In this work, mechanical and tribological properties were evaluated on tibial trays obtained via MIM and conventional investment casting. Surface hardness and wear properties were evaluated through Vickers hardness, scratch and pin on disk tests. The MIM and cast finished tibial trays were then subjected to a fatigue test campaign in order to obtain their fatigue load limit at 5 millions cycles following ISO 14879-1 directions. CoCrMo cast alloy exhibited 514 HV hardness compared to 335 HV of MIM alloy, furthermore it developed narrower scratches with a higher tendency towards microploughing than microcutting, in comparison to MIM CoCrMo. The observed fatigue limits were (1,766 ± 52) N for cast tibial trays and (1,625 ± 44) N for MIM ones. Fracture morphologies pointed out to a more brittle behavior of MIM microstructure. These aspects were attributed to the absence of a fine toughening and surface hardening carbide dispersion in MIM grains. Nevertheless, MIM tibial trays exhibited a fatigue limit far beyond the 900 N of maximum load prescribed by ISO and ASTM standards for the clinical application of these devices.
Fruits and vegetables displace, but do not decrease, total energy in school lunches.
Bontrager Yoder, Andrea B; Schoeller, Dale A
2014-08-01
The high overweight and obesity prevalence among US children is a well-established public health concern. Diet is known to play a causal role in obesity. Increasing fruit and vegetable (FV) consumption to recommended levels is proposed to help reduce obesity, because their bulk and low energy density are believed to reduce energy-dense food consumption (volume displacement hypothesis). This study tests this hypothesis at the lunch meal among upper-elementary students participating in a Farm to School (F2S) program. Digital photographs of students' school lunch trays were visually analyzed to identify the food items and amounts that were present and consumed before and after the meal. Using the USDA Nutrient Database, total and FV-only energy were calculated for each tray. Analysis of total- and non-FV energy intake was performed according to (1) levels of FV energy intake, (2) FV energy density, and (3) previous years of Farm to School programming. Higher intake of FV energy displaced non-FV energy, but total energy did not decrease across FV energy intake groups. High-FV-energy-density trays showed lower non-FV energy intake than low-FV-energy-density trays (470±179 vs. 534±219 kcal; p<0.0001). Trays from schools with more previous years of F2S programming decreased total and non-FV energy intake from school lunches (p for trend<0.0001, both). Increased FV consumption reduces non-FV energy intake, but does not reduce total energy intake. Therefore, this study does not support the volume displacement hypothesis and suggests calorie displacement instead.
2014-03-01
originates at a large levee, which was built to create a water retention (to control excess water) and water bird management area. The levee and canal...each sample was dried in stainless steel trays in a 60 °C convection oven . Two methods of quantitative analysis were performed to determine the...ERDC/TN ANSRP-14-1 March 2014 Approved for public release; distribution is unlimited. Burrowing by Sailfin Catfish (Pterygoplichthys sp.): A
USDA-ARS?s Scientific Manuscript database
Binucelate Rhizoctonia sp. (BNR), the cause of web blight, can be spread on azalea stem cuttings into propagation houses, but can be eliminated from stems by submerging cuttings in 50°C water for 21 minutes. The overall objective was to evaluate risk of rooting cuttings in trays becoming contaminate...
ERIC Educational Resources Information Center
Etheredge, Lloyd S.
This student manual is intended to help undergraduate political science students analyze human behavior. The manual poses the problem of why a group of high school students failed to take their cafeteria trays to the dirty dish room. It presents alternative solutions which students discuss as they explore various interpretations of human…
Hand dermatitis in auto mechanics and machinists.
Donovan, Jeffrey C H; Kudla, Irena; Holness, D Linn
2007-09-01
Auto mechanics and machinists presenting with suspected allergic contact dermatitis (ACD) have traditionally been patch-tested with a standard screening tray and a specialty tray such as the Oil and Cooling Fluid Series. While this has proven useful for patch-testing the machinist, there is a need for the development of a more specific allergen testing tray for the auto mechanic. The objective of the study was to compare clinical features and patch-test results of auto mechanics and machinists with hand dermatitis to evaluate differences in allergen profiles. We performed a chart review of 33 auto mechanics and 24 machinists referred to our Occupational Contact Dermatitis Clinic from 2002 to 2005 for evaluation of hand dermatitis. With a panel of 84 allergens, 52 positive reactions were detected in 17 cases of ACD in mechanics. The profiles were different from the cases of ACD diagnosed in 10 of 24 machinists. Mechanics and machinists differ in the spectrum of occupational exposures. Patch testing with greater numbers of allergens likely identifies a larger proportion of mechanics with occupationally relevant ACD. Further study is needed to determine the most appropriate allergens to include in a clinically useful "mechanic's tray."
Tropical field performance of dual-pass PV tray dryer
NASA Astrophysics Data System (ADS)
Iskandar, A. Noor; Ya'acob, M. E.; Anuar, M. S.
2017-09-01
Solar Photovoltaic technology has become the preferable solution in many countries around the globe to solve the ever increasing energy demand of the consumers. In line with the consumer need, food processing technology has huge potentials of integration with the renewable energy resources especially in drying process which consumes the highest electricity loads. Traditionally, the solar dryer technology was applied in agriculture and food industries utilizing the sun's energy for drying process, but this is highly dependable on the weather condition and surrounding factors. This work shares some field performance of the new design of portable dual-pass PV tray dryer for drying crops in an enclosed system. The dual-pass PV tray dryer encompass a lightweight aluminium box structure with dimensions of 1.1m (L) x 0.6m (W) x 0.2m (H) and can hold a load capacity of 300g - 3kg of crop depending on the types of the crops. Experiments of field performance monitoring were conducted in October -November 2016 which justifies a considerable reduction in time and crops quality improvement when using the dual-pass PV tray dryer as compared to direct-sun drying.
Baig, Mirza Rustum; Akbar, Jaber Hussain; Qudeimat, Muawia; Omar, Ridwaan
2018-02-15
To evaluate the effects of impression material, impression tray type, and type of partial edentulism (ie, Kennedy class) on the accuracy of fit of cobalt-chromium (Co-Cr) partial removable dental prostheses (PRDP) in terms of the number of fabricated frameworks required until the attainment of adequate fit. Electronic case documentations of 120 partially edentulous patients provided with Co-Cr PRDP treatment for one or both arches were examined. Statistical analyses of data were performed using analysis of variance and Tukey honest significant difference test to compare the relationships between the different factors and the number of frameworks that needed to be fabricated for each patient (α = .05). Statistical analysis of data derived from 143 records (69 maxillary and 74 mandibular) revealed no significant correlation between impression material, tray type, or Kennedy class and the number of construction attempts for the pooled or individual arch data (P ≥ .05). In PRDP treatment, alginate can be chosen as a first-choice material, and metal stock trays can be a preferred option for making final impressions to fabricate Co-Cr frameworks.
Aulenbach, Brent T.
2010-01-01
Bacteria holding-time experiments of up to 62 h were performed on five surface-water samples from four urban stream sites in the vicinity of Atlanta, GA, USA that had relatively high densities of coliform bacteria (Escherichia coli densities were all well above the US Environmental Protection Agency criterion of 126 colonies (100 ml) − 1 for recreational waters). Holding-time experiments were done for fecal coliform using the membrane filtration modified fecal coliform (mFC) agar method and for total coliform and E. coli using the Colilert®-18 Quanti-Tray® method. The precisions of these analytical methods were quantified. Precisions determined for fecal coliform indicated that the upper bound of the ideal range of counts could reasonably be extended upward and would improve precision. For the Colilert®-18 method, analytical precisions were similar to the theoretical precisions for this method. Fecal and total coliform densities did not change significantly with holding times up to about 27 h. Limited information indicated that fecal coliform densities might be stable for holding times of up to 62 h, whereas total coliform densities might not be stable for holding times greater than about 27 h. E. coli densities were stable for holding times of up to 18 h—a shorter period than indicated from a previous studies. These results should be applicable to non-regulatory monitoring sampling designs for similar urban surface-water sample types.
USDA-ARS?s Scientific Manuscript database
Binucelate Rhizoctonia spp. (BNR), the cause of web blight, are present all year on container-grown azaleas in the southern U.S. BNR can be eliminated during vegetative propagation by submerging stem cuttings in 50°C water for 21 minutes. The objective was to evaluate risk of rooting trays being con...
Fluid Management of and Flame Spread Across Liquid Pools
NASA Technical Reports Server (NTRS)
Ross, H. D.; Miller, F. J.
2001-01-01
The goal of our research on flame spread across pools of liquid fuel remains the quantitative identification of the mechanisms that control the rate and nature of flame spread when the initial temperature of the liquid pool is below the fuel's flash point temperature. As described in, four microgravity (mu-g) sounding rocket flights examined the effect of forced opposed airflow over a 2.5 cm deep x 2 cm wide x 30 cm long pool of 1-butanol. Among many unexpected findings, it was observed that the flame spread is much slower and steadier than in 1g where flame spread has a pulsating character. Our numerical model, restricted to two dimensions, had predicted faster, pulsating flame spread in mu-g. In a test designed to achieve a more 2-D experiment, our investigation of a shallow, wide pool (2 mm deep x 78 mm wide x 30 cm long) was unsuccessful in mu-g, due to an unexpectedly long time required to fill the tray. As such, the most recent Spread Across Liquids (SAL) sounding rocket experiment had two principal objectives: 1) determine if pulsating flame spread in deep fuel trays would occur under the conditions that a state-of-the-art computational combustion code and short-duration drop tower tests predict; and 2) determine if a long, rectangular, shallow fuel tray could achieve a visibly flat liquid surface across the whole tray without spillage in the mu-g time allotted. If the second objective was met, the shallow tray was to be ignited to determine the nature of flame spread in mu-g for this geometry. For the first time in the experiment series, two fuel trays - one deep (30 cm long x 2 cm wide x 25 mm deep) and one shallow (same length and width, but 2 mm deep)-- were flown. By doing two independent experiments in a single flight, a significant cost savings was realized. In parallel, the computational objective was to modify the code to improve agreement with earlier results. This last objective was achieved by modifying the fuel mass diffusivity and adding a parameter to correct for radiative and lateral heat loss.
Study on The Effectiveness of Egg Tray and Coir Fibre as A Sound Absorber
NASA Astrophysics Data System (ADS)
Kaamin, Masiri; Farah Atiqah Ahmad, Nor; Ngadiman, Norhayati; Kadir, Aslila Abdul; Razali, Siti Nooraiin Mohd; Mokhtar, Mardiha; Sahat, Suhaila
2018-03-01
Sound or noise pollution has become one major issues to the community especially those who lived in the urban areas. It does affect the activity of human life. This excessive noise is mainly caused by machines, traffic, motor vehicles and also any unwanted sounds that coming from outside and even from the inside of the building. Such as a loud music. Therefore, the installation of sound absorption panel is one way to reduce the noise pollution inside a building. The selected material must be a porous and hollow in order to absorb high frequency sound. This study was conducted to evaluate the potential of egg tray and coir fibre as a sound absorption panel. The coir fibre has a good coefficient value which make it suitable as a sound absorption material and can replace the traditional material; syntactic and wooden material. The combination of pyramid shape of egg tray can provide a large surface for uniform sound reflection. This study was conducted by using a panel with size 1 m x 1 m with a thickness of 6 mm. This panel consist of egg tray layer, coir fibre layer and a fabric as a wrapping for the aesthetic value. Room reverberation test has been carried to find the loss of reverberation time (RT). Result shows that, a reverberation time reading is on low frequency, which is 125 Hz to 1600 Hz. Within these frequencies, this panel can shorten the reverberation time of 5.63s to 3.60s. Hence, from this study, it can be concluded that the selected materials have the potential as a good sound absorption panel. The comparison is made with the previous research that used egg tray and kapok as a sound absorption panel.
Fruits and Vegetables Displace, But Do Not Decrease, Total Energy in School Lunches
Schoeller, Dale A.
2014-01-01
Abstract Background: The high overweight and obesity prevalence among US children is a well-established public health concern. Diet is known to play a causal role in obesity. Increasing fruit and vegetable (FV) consumption to recommended levels is proposed to help reduce obesity, because their bulk and low energy density are believed to reduce energy-dense food consumption (volume displacement hypothesis). This study tests this hypothesis at the lunch meal among upper-elementary students participating in a Farm to School (F2S) program. Methods: Digital photographs of students' school lunch trays were visually analyzed to identify the food items and amounts that were present and consumed before and after the meal. Using the USDA Nutrient Database, total and FV-only energy were calculated for each tray. Analysis of total- and non-FV energy intake was performed according to (1) levels of FV energy intake, (2) FV energy density, and (3) previous years of Farm to School programming. Results: Higher intake of FV energy displaced non-FV energy, but total energy did not decrease across FV energy intake groups. High-FV-energy-density trays showed lower non-FV energy intake than low-FV-energy-density trays (470±179 vs. 534±219 kcal; p<0.0001). Trays from schools with more previous years of F2S programming decreased total and non-FV energy intake from school lunches (p for trend<0.0001, both). Conclusions: Increased FV consumption reduces non-FV energy intake, but does not reduce total energy intake. Therefore, this study does not support the volume displacement hypothesis and suggests calorie displacement instead. PMID:24988122
Iwasaki, Masatoshi; Kawara, Misao; Inoue, Sayumi; Komiyama, Osamu; Iida, Takashi; Asano, Takashi
2016-04-01
The purpose of this study is to compare the pressure dynamics in the trays caused by differences in the various impression materials and in the thickness of the relief provided for the trays. In this study, two types of polyvinylsiloxane elastomers, one type of polyether elastomer and one type of alginate impression material were used. Pressure sensors were embedded at eight locations in a model of an edentulous maxilla, and used a simulation model covered with a pseudomucosa. For each impression material, the measurement was performed five times for each of the three types of trays, and the mean values were determined. Statistical analysis was carried out using one-way analysis of variance and the Tukey's HDS method, and the various pressure sensor values for each of the impression materials were compared 10s and 20s after the start of the measurement. Additionally, we compared differences among the three types of trays after 20s. The pressure values for sensors placed in the relief region tended to become uniform. Furthermore, we saw a tendency for the pressure to increase at the alveolar crests of the first molars on the left and right and at the posterior border of the palate, all of which support the denture, when relief was provided. The above results suggest that making the final impression for the denture using the selective pressure technique, with consideration given to the pressure dynamic, may lead to a good outcome in terms of preservation of the alveolar ridge. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Numerical simulations of regolith sampling processes
NASA Astrophysics Data System (ADS)
Schäfer, Christoph M.; Scherrer, Samuel; Buchwald, Robert; Maindl, Thomas I.; Speith, Roland; Kley, Wilhelm
2017-07-01
We present recent improvements in the simulation of regolith sampling processes in microgravity using the numerical particle method smooth particle hydrodynamics (SPH). We use an elastic-plastic soil constitutive model for large deformation and failure flows for dynamical behaviour of regolith. In the context of projected small body (asteroid or small moons) sample return missions, we investigate the efficiency and feasibility of a particular material sampling method: Brushes sweep material from the asteroid's surface into a collecting tray. We analyze the influence of different material parameters of regolith such as cohesion and angle of internal friction on the sampling rate. Furthermore, we study the sampling process in two environments by varying the surface gravity (Earth's and Phobos') and we apply different rotation rates for the brushes. We find good agreement of our sampling simulations on Earth with experiments and provide estimations for the influence of the material properties on the collecting rate.
ERIC Educational Resources Information Center
Qu, Li
2011-01-01
The current study investigated how playing with another individual may influence 3- and 4-year-olds' executive function in the Less-Is-More (LIM) task, where children point to the tray with the smaller amount of treats so as to obtain the larger amount of treats in the other tray. In Experiment 1, 35 Singaporean children were tested with a self…
Improved alignment and operating room efficiency with patient-specific instrumentation for TKA.
Renson, Luc; Poilvache, Pascal; Van den Wyngaert, Hans
2014-12-01
Achieving accurate alignment in total knee arthroplasty (TKA) remains a concern. Patient-specific instrumentation (PSI) produced using preoperative 3D models was developed to offer surgeons a simplified, reliable, efficient and customised TKA procedure. In this prospective study, 60 patients underwent TKA with conventional instrumentation and 71 patients were operated on using PSI. The primary endpoint was surgical time. Secondary endpoints included operating room (OR) time, the number of instrument trays used and postoperative radiographic limb alignment. Compared to conventional instrumentation, PSI significantly reduced total surgical time by 8.9 ± 3.3 min (p=0.038), OR time by 8.6 ± 4.2 min (p=0.043), and the number of instrument trays by six trays (p<0.001). Mechanical axis malalignment of the lower limb of >3° was observed in 13% of PSI patients versus 29% with conventional instrumentation (p=0.043). PSI predicted the size of the femoral and tibial components actually used in 85.9% and 78.9% of cases, respectively. PSI improves alignment, surgical and OR time, reduces the number of instruments trays used compared to conventional instrumentation in patients undergoing TKA and results in fewer outliers in overall mechanical alignment in the coronal plane. Prospective comparative therapeutic study. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Sadeghifar, Hamidreza
2015-10-01
Developing general methods that rely on column data for the efficiency estimation of operating (existing) distillation columns has been overlooked in the literature. Most of the available methods are based on empirical mass transfer and hydraulic relations correlated to laboratory data. Therefore, these methods may not be sufficiently accurate when applied to industrial columns. In this paper, an applicable and accurate method was developed for the efficiency estimation of distillation columns filled with trays. This method can calculate efficiency as well as mass and heat transfer coefficients without using any empirical mass transfer or hydraulic correlations and without the need to estimate operational or hydraulic parameters of the column. E.g., the method does not need to estimate tray interfacial area, which can be its most important advantage over all the available methods. The method can be used for the efficiency prediction of any trays in distillation columns. For the efficiency calculation, the method employs the column data and uses the true rates of the mass and heat transfers occurring inside the operating column. It is highly emphasized that estimating efficiency of an operating column has to be distinguished from that of a column being designed.
Standardizing the Delivery of 20 μL of Hapten During Patch Testing.
Selvick, Annika; Stauss, Kari; Strobush, Katrina; Taylor, Lauren; Picard, Alexandra; Doll, Andrea; Reeder, Margo
2016-01-01
The current method for patch test tray assembly requires hand dispensing a small volume of hapten onto chambers. Because of human error, this technique produces inaccurate and inconsistent results. The recommended volume of hapten for patch testing using Finn Chambers is 20 μL. The aims of this study were to create a device that standardizes the delivery of 20 μL and to compare it with the current hand dispensing technique. A device, named the Revolution, was created using the SolidWorks program. Five nurses in our Contact Dermatitis Clinic were asked to load 10 Finn Chambers using the current technique and also using the Revolution. Assembly time, volume of petrolatum, and accuracy of placement were measured. After the 3 trials, the nurses completed a survey on the 2 methods. The amount of petrolatum dispensed using the current technique ranged from 16 to 85 μL, with an average amount of 41.39 μL. The Revolution design dispensed an average of 19.78 μL. The current hand dispensing technique does not allow for accurate and consistent dispensing of 20 μL for patch testing. In contrast, the Revolution is an accurate and consistent device that can help standardize the patch testing method.
The validation of procedures to assess prevocational task preferences in retarded adults.
Mithaug, D E; Hanawalt, D A
1978-01-01
Three severely retarded young adults between the ages of 19 and 21 years participated in a prevocational training program, and worked regularly on six different tasks during the scheduled six-hour day. The study attempted to assess each subject's preferences for the six tasks: collating, stuffing, sorting, pulley assembly, flour-sifter assembly, and circuit-board stuffing. In Phase I, the procedure consisted of randomly pairing each task with all other tasks in a two-choice situation that required the subjects to select one task from each pair combination to work for a seven-minute period. The selection procedure consisted of presenting two representative task objects on a tray and requesting the subject to pick up one object and place it on the work table. The object selected represented the task worked for that period. The 15 possible pair combinations were presented randomly every two days for a period of 34 days to determine the preferences. During the validation phase (Phase II), each subject's least- and most-preferred tasks were paired separately with moderately-preferred tasks. As expected, these manipulations confirmed the baseline data, as choices for the moderately-preferred tasks decreased when consistently paired with the preferred tasks and increased when consistently paired with the least-preferred tasks.
Methods and compositions for rapid thermal cycling
Beer, Neil Reginald; Benett, William J.; Frank, James M.; Deotte, Joshua R.; Spadaccini, Christopher
2015-10-27
The rapid thermal cycling of a material is targeted. A microfluidic heat exchanger with an internal porous medium is coupled to tanks containing cold fluid and hot fluid. Fluid flows alternately from the cold tank and the hot tank into the porous medium, cooling and heating samples contained in the microfluidic heat exchanger's sample wells. A valve may be coupled to the tanks and a pump, and switching the position of the valve may switch the source and direction of fluid flowing through the porous medium. A controller may control the switching of valve positions based on the temperature of the samples and determined temperature thresholds. A sample tray for containing samples to be thermally cycled may be used in conjunction with the thermal cycling system. A surface or internal electrical heater may aid in heating the samples, or may replace the necessity for the hot tank.
Methods and compositions for rapid thermal cycling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beer, Neil Reginald; Benett, William J.; Frank, James M.
The rapid thermal cycling of a material is targeted. A microfluidic heat exchanger with an internal porous medium is coupled to tanks containing cold fluid and hot fluid. Fluid flows alternately from the cold tank and the hot tank into the porous medium, cooling and heating samples contained in the microfluidic heat exchanger's sample wells. A valve may be coupled to the tanks and a pump, and switching the position of the valve may switch the source and direction of fluid flowing through the porous medium. A controller may control the switching of valve positions based on the temperature ofmore » the samples and determined temperature thresholds. A sample tray for containing samples to be thermally cycled may be used in conjunction with the thermal cycling system. A surface or internal electrical heater may aid in heating the samples, or may replace the necessity for the hot tank.« less
Analysis of Cometary Dust Impact Residues in the Aluminum Foil Craters of Stardust
NASA Technical Reports Server (NTRS)
Graham, G. A.; Kearsley, A. T.; Vicenzi, E. P.; Teslich, N.; Dai, Z. R.; Rost, D.; Horz, F.; Bradley, J. P.
2007-01-01
In January 2006, the sample return capsule from NASA s Stardust spacecraft successfully returned to Earth after its seven year mission to comet Wild-2. While the principal capture medium for comet dust was low-density graded silica aerogel, the 1100 series aluminum foil (approximately 100 m thick) which wrapped around the T6064 aluminum frame of the sample tray assembly (STA) contains micro-craters that constitute an additional repository for Wild-2 dust. Previous studies of similar craters on spacecraft surfaces, e.g. the Long Duration Exposure Facility (LDEF), have shown that impactor material can be preserved for elemental and mineralogical characterization, although the quantity of impact residue in Stardust craters far exceeds previous missions. The degree of shock-induced alteration experienced by the Wild-2 particles impacting on foil will generally be greater than for those captured in the low-density aerogel. However, even some of the residues found in LDEF craters showed not only survival of crystalline silicates but even their solar flare tracks, which are extremely fragile structures and anneal at around 600 C. Laboratory hypervelocity experiments, using analogues of Wild-2 particles accelerated into flight-grade foils under conditions close to those of the actual encounter, showed retention of abundant projectile residues at the Stardust encounter velocity of 6.1 km/s. During the preliminary examination (PE) of the returned foils, using optical and electron microscopy studies, a diverse range in size and morphologies of micro-craters was identified. In this abstract we consider the state of residue preservation in a diverse range of craters with respect to their elemental composition and inferred mineralogy of the original projectiles.
Scanning electron microscope/energy dispersive x ray analysis of impact residues in LDEF tray clamps
NASA Technical Reports Server (NTRS)
Bernhard, Ronald P.; Durin, Christian; Zolensky, Michael E.
1993-01-01
Detailed optical scanning of tray clamps is being conducted in the Facility for the Optical Inspection of Large Surfaces at JSC to locate and document impacts as small as 40 microns in diameter. Residues from selected impacts are then being characterized by Scanning Electron Microscopy/Energy Dispersive X-ray Analysis at CNES. Results from this analysis will be the initial step to classifying projectile residues into specific sources.
French payload specialist Patrick Baudry prepares a meal
NASA Technical Reports Server (NTRS)
1985-01-01
Payload specialist Patrick Baudry, representing the Centre National d'Etudes Spatiales of France, prepares to open a can of lobster. The bag attached to the nearby middeck locker door appears to contain several other French snacks. His food tray is also attached to the middeck lockers. Behind his head are other food trays attached to the shuttle rehydration unit. A roll of duct tape floats in space to one side of Baudry.
Design of Control System for Flexible Packaging Bags Palletizing Production Line Based on PLC
NASA Astrophysics Data System (ADS)
Zheng, Huiping; Chen, Lin; Zhao, Xiaoming; Liu, Zhanyang
Flexible packaging bags palletizing production line is to put the bags in the required area according to particular order and size, in order to finish handling, storage, loading and unloading, transportation and other logistics work of goods. Flexible packaging bags palletizing line is composed of turning bags mechanism, shaping mechanism, indexing mechanism, marshalling mechanism, pushing bags mechanism, pressing bags mechanism, laminating mechanism, elevator, tray warehouse, tray conveyor and loaded tray conveyor. Whether the whole production line can smoothly run depends on each of the above equipment and precision control among them. In this paper the technological process and the control logic of flexible packaging bags palletizing production line is introduced. Palletizing process of the production line realized automation by means of a control system based on programmable logic controller (PLC). It has the advantages of simple structure, reliable and easy maintenance etc.
T-ray relevant frequencies for osteosarcoma classification
NASA Astrophysics Data System (ADS)
Withayachumnankul, W.; Ferguson, B.; Rainsford, T.; Findlay, D.; Mickan, S. P.; Abbott, D.
2006-01-01
We investigate the classification of the T-ray response of normal human bone cells and human osteosarcoma cells, grown in culture. Given the magnitude and phase responses within a reliable spectral range as features for input vectors, a trained support vector machine can correctly classify the two cell types to some extent. Performance of the support vector machine is deteriorated by the curse of dimensionality, resulting from the comparatively large number of features in the input vectors. Feature subset selection methods are used to select only an optimal number of relevant features for inputs. As a result, an improvement in generalization performance is attainable, and the selected frequencies can be used for further describing different mechanisms of the cells, responding to T-rays. We demonstrate a consistent classification accuracy of 89.6%, while the only one fifth of the original features are retained in the data set.
Pay attention to reflux/feed entry design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fleming, B.; Martin, G.R.; Hartman, E.L.
1996-01-01
Trays generally are forgiving pieces of equipment and can conceal the effects of poorly designed feed and reflux entries. When one tries to push a tower to its hydraulic limit, however, poor entry design can penalize the performance of the trays and result in a lower final capacity. Normally, new towers are not as susceptible to entry design problems as ones being revamped. This is because new towers usually have some degree of capacity oversizing.Standard design practices used for new columns having spare capacity, though, may not be suitable for revamped towers. In this article, the authors detail the basicmore » principles of reflux and feed entry design, good practices to follow, and poor practices to avoid. They also include a case study of a large-diameter light hydrocarbon splitter revamped with high capacity trays to illustrate the potential pitfalls associated with incorrectly designed reflux and feed entry arrangements.« less
NASA Technical Reports Server (NTRS)
Simon, Charles G.; Hunter, J. L.; Griffis, D. P.; Misra, V.; Ricks, D. A.; Wortman, Jim J.; Brownlee, D. E.
1993-01-01
The Interplanetary Dust Experiment (IDE) had over 450 electrically active ultra-high purity metal-oxide-silicon impact detectors located on the six primary sides of the Long Duration Exposure Facility (LDEF). Hypervelocity microparticles (approximately 0.2 to approximately 100 micron diameter) that struck the active sensors with enough energy to break down the 0.4 or 1.0 micron thick SIO2 insulator layer separating the silicon base (the negative electrode), and the 1000 A thick surface layer of aluminum (the positive electrode) caused electrical discharges that were recorded for the first year of orbit. The high purity Al-SiO2-Si substrates allowed detection of trace (ppm) amounts of hypervelocity impactor residues. After sputtering through a layer of surface contamination, secondary ion mass spectrometry (SIMS) was used to create two-dimensional elemental ion intensity maps of microparticle impact sites on the IDE sensors. The element intensities in the central craters of the impacts were corrected for relative ion yields and instrumental conditions and then normalized to silicon. The results were used to classify the particles' origins as 'manmade,' 'natural,' or 'indeterminate.' The last classification resulted from the presence of too little impactor residue, analytical interference from high background contamination, the lack of information on silicon and aluminum residues, or a combination of these circumstances. Several analytical 'blank' discharges were induced on flight sensors by pressing down on the sensor surface with a pure silicon shard. Analyses of these blank discharges showed that the discharge energy blasts away the layer of surface contamination. Only Si and Al were detected inside the discharge zones, including the central craters of these features. Thus far a total of 79 randomly selected microparticle impact sites from the six primary sides of the LDEF have been analyzed: 36 from tray C-9 (Leading (ram), or East, side), 18 from tray C-3 (Trailing (wake), or West, side), 12 from tray B-12 (North side), 4 from tray D-6 (South side), 3 from tray H-11 (Space end), and 6 from tray G-10 (Earth end). Residue from manmade debris was identified in craters on all trays. (Aluminum oxide particle residues were not detectable on the Al/Si substrates.) These results were consistent with the IDE impact record which showed highly variable long term microparticle impact flux rates on the West, Space and Earth sides of the LDEF which could not be ascribed to astronomical variability of micrometeorite density. The IDE record also showed episodic bursts of microparticle impacts on the East, North, and South sides of the satellite, denoting passage through orbital debris clouds or rings.
NASA Technical Reports Server (NTRS)
Simon, C. G.; Hunter, J. L.; Griffis, D. P.; Misra, V.; Ricks, D. A.; Wortman, J. J.; Brownlee, D. E.
1992-01-01
The Interplanetary Dust Experiment (IDE) had over 450 electrically active ultra-high purity metal-oxide-silicon impact detectors located on the six primary sides of the Long Duration Exposure Facility (LDEF). Hypervelocity microparticles (approximately 0.2 to approximately 100 micron diameter) that struck the active sensors with enough energy to breakdown the 0.4 or 1.0 micron thick SiO2 insulator layer separating the silicon base (the negative electrode), and the 1000 A thick surface layer of aluminum (the positive electrode) caused electrical discharges that were recorded for the first year of orbit. The high purity Al-SiO2-Si substrates allowed detection of trace (ppm) amounts of hypervelocity impactor residues. After sputtering through a layer of surface contamination, secondary ion mass spectrometry (SIMS) was used to create two-dimensional elemental ion intensity maps of microparticle sites on the IDE sensors. The element intensities in the central craters of the impacts were corrected for relative ion yields and instrumental conditions and then normalized to silicon. The results classification resulted from the particles' origins as 'manmade', 'natural', or 'indeterminate'. The last classification resulted from the presence of too little impactor residue, analytical interference from high background contamination, the lack of information on silicon and aluminum residues, or a combination of these circumstances. Several analytical 'blank' discharges were induced on flight sensors by pressing down on the sensor surface with a pure silicon shard. Analyses of these blank discharges showed that the discharge energy blasts away the layer of surface contamination. Only Si and Al were detected inside the discharge zones, including the central craters, of these features. Thus far, a total of 79 randomly selected microparticle impact sites from the six primary sides of the LDEF were analyzed: 36 from tray C-9 (Leading (ram), or east, side), 18 from tray C-3 (Trailing (wake), or west, side), 12 from tray B-12 (north side), 4 from tray D-6 (south side), 3 from tray H-11 (space end), and 6 from tray G-10 (earth end). Residue from manmade debris was identified in craters on all trays (aluminum oxide particle residues were not detectable on the Al/Si substrates). These results were consistent with the IDE impact record which showed highly variable long term microparticle impact flux rates on the west, space, and Earth sides of the LDEF which could not be ascribed to astronomical variability of micrometeorite density. The IDE record also showed episodic bursts of microparticle impacts on the east, north, and south sides of the satellite, denoting passage through orbital debris clouds or rings.
Donahue, W; Bongiorni, P; Hearn, R; Rodgers, J; Nath, R; Chen, Z
2012-06-01
To develop and characterize a novel thermal reservoir for consistent and accurate annealing of high-sensitivity thermoluminescence dosimeters (TLD-100H) for dosimetry of brachytherapy sources. The sensitivity of TLD-100H is about 18 times that of TLD-100 which has clear advantages in for interstitial brachytherapy sources. However, the TLD-100H requires a short high temperature annealing cycle (15 min.) and opening and closing the oven door causes significant temperature fluctuations leading to unreliable measurements. A new thermal reservoir made of aluminum alloy was developed to provide stable temperature environment in a standard hot air oven. The thermal reservoir consisted of a 20 cm × 20 cm × 8 cm Al block with a machine-milled chamber in the middle to house the aluminum TLD holding tray. The thermal reservoir was placed inside the oven until it reaches thermal equilibrium with oven chamber. The temperatures of the oven chamber, heat reservoir, and TLD holding tray were monitored by two independent thermo-couples which interfaced digitally to a control computer. A LabView interface was written for monitoring and recording the temperatures in TLD holding tray, the thermal reservoir, and oven chamber. The temperature profiles were measured as a function of oven-door open duration. The settings for oven chamber temperature and oven door open-close duration were optimized to achieve a stable temperature of 240 0C in the TLD holding tray. Complete temperature profiles of the TLD annealing tray over the entire annealing process were obtained. A LabView interface was written for monitoring and recording the temperatures in TLD holding The use of the thermal reservoir has significantly reduced the temperature fluctuations caused by the opening of oven door when inserting the TLD holding tray into the oven chamber. It has enabled consistent annealing of high-sensitivity TLDs. A comprehensive characterization of a custom-built novel thermal reservoir for annealing high-sensitivity TLD has been carried out. It enabled consistent and accurate annealing of high- sensitivity TLDs which could significantly improve the efficiency of brachytherapy source characterizations. Supported in part by NIH grant R01-CA134627. © 2012 American Association of Physicists in Medicine.
NASA Technical Reports Server (NTRS)
Wirick, S.; Flynn, G. J.; Frank, D.; Sandford, S. A.; Zolensky, M. E.; Tsou, P.; Peltzer, C.; Jacobsen, C.
2009-01-01
Great care and a large effort was made to minimize the amount of organic matter contained within the flight aerogel used to collect Comet 81P/Wild 2 samples. Even so, by the very nature of the production process and silica aerogel s affinity for volatile organics keeping silica aerogel free from organics is a monumental task. Silica aerogel from three production batches was flown on the Stardust sample return mission. All 3 types had layered densities varying from 5mg/ml to 50 mg/ml where the densest aerogel was farthest away from the collection area. A 2 step gelation process was used to make the flight aerogel and organics used in this process were tetraethylorthosilicate, ethanol and acetonitrile. Both ammonium hydroxide and nitric acid were also used in the aerogel production process. The flight aerogel was baked at JPL at 300 C for 72 hours, most of the baking was done at atmosphere but twice a day the oven was pumped to 10 torr for hour [1]. After the aerogel was baked it was stored in a nitrogen purged cabinet until flight time. One aerogel cell was located in the SRC away from any sample collection area as a witness to possible contamination from out gassing of the space craft, re-entry gases and any other organic encounter. This aerogel was aerogel used in the interstellar collection sample tray and is the least dense of the 3 batches of aerogel flown. Organics found in the witness tile include organics containing Si-CH3 bonds, amines and PAHS. Besides organic contamination, hot spots of calcium were reported in the flight aerogel. Carbonates have been detected in comet 81P/Wild2 samples . During preflight analyses, no technique was used to analyze for carbonates in aerogel. To determine if the carbonates found in 81P/Wild2 samples were from the comet, it is necessary to analyze the flight aerogel for carbonate as well as for organics.
Motion Law Analysis and Structural Optimization of the Ejection Device of Tray Seeder
NASA Astrophysics Data System (ADS)
Luo, Xin; Hu, Bin; Dong, Chunwang; Huang, Lili
An ejection mechanism consisting four reset springs, an electromagnet and a seed disk was designed for tray seeder. The motion conditions of seeds in the seed disk were theoretical analyzed and intensity and height of seed ejection were calculated. The motions of the seeds and seed disk were multi-body dynamic simulated using Cosmos modules plug-in SolidWorks software package. The simulation results showed the consistence with the theoretical analysis.
Potato growth and yield using nutrient film technique (NFT)
NASA Technical Reports Server (NTRS)
Wheeler, R. M.; Mackowiak, C. L.; Sager, J. C.; Knott, W. M.; Hinkle, C. R.
1990-01-01
Potato plants, cvs Denali and Norland, were grown in polyvinyl chloride (PVC) trays using a continuous flowing nutrient film technique (NFT) to study tuber yield for NASA's Controlled Ecological Life Support Systems (CELSS) program. Nutrient solution pH was controlled automatically using 0.39M (2.5% (v/v) nitric acid (HNO3), while water and nutrients were replenished manually each day and twice each week, respectively. Plants were spaced either one or two per tray, allotting 0.2 or 0.4 m2 per plant. All plants were harvested after 112 days. Denali plants yielded 2850 and 2800 g tuber fresh weight from the one- and two-plant trays, respectively, while Norland plants yielded 1800 and 2400 g tuber fresh weight from the one- and two-plant trays. Many tubers of both cultivars showed injury to the periderm tissue, possibly caused by salt accumulation from the nutrient solution on the surface. Total system water usage throughout the study for all the plants equaled 709 liters (L), or approximately 2 L m-2 d-1. Total system acid usage throughout the study (for nutrient solution pH control) equaled 6.60 L, or 18.4 ml m-2 d-1 (7.2 mmol m-2 d-1). The results demonstrate that continuous flowing nutrient film technique can be used for tuber production with acceptable yields for the CELSS program.
Materials for interocclusal records and their ability to reproduce a 3-dimensional jaw relationship.
Ockert-Eriksson, G; Eriksson, A; Lockowandt, P; Eriksson, O
2000-01-01
The purpose of this study was to determine if accuracy and dimensional stability of vinyl polysiloxanes and irreversible hydrocolloids stabilized by a tray used for fixed prosthodontics, removable partial, and complete denture cases are comparable to those of waxes and record rims and if storage time (24 hours or 6 days) affects dimensional stability of the tested materials. Two waxes, two record rims, three vinyl polysiloxanes, and one irreversible hydrocolloid (alginate) were examined. Three pairs of master casts with measuring steel rods were mounted on an articulator (initial position). Five records were made of each material, and the upper cast was remounted after 24 hours or 6 days so that deviations from the initial position could be measured. Vinyl polysiloxanes reinforced by a stabilization tray were the most accurate materials able to reproduce a settled interocclusal position. Mounting casts (fixed prosthodontics cases) without records gave accuracy similar to wax records. Record rims used for removable partial and complete denture cases produced lesser accuracy than vinyl polysiloxanes and irreversible hydrocolloid stabilized by a tray. Accuracy was not significantly affected by storage time. The results show that accuracy of vinyl polysiloxanes and irreversible hydrocolloids reinforced by a tray is superior to that of record rims with regard to the complete denture case and is among the most accurate with regard to the removable partial denture case. For fixed prosthodontics, however, reinforcement is unnecessary.
Utto, Weerawate; Preutikul, Rittirong; Malila, Patcharee; Noomhorm, Athapol; Bronlund, John E
2018-03-01
This research was conducted to investigate effects of ethanol vapour released in active packaging and storage temperatures on the quality of freshly peeled shallots. The package tested was a solid polypropylene tray incorporating an ethanol vapour-controlled release sachet. The sachet was made of an aluminium foil film on one side and either low-density polyethylene or nylon/polyethylene on the other. Individual sachets contained silica gel adsorbent as the carrier pre-loaded with ethanol. One sachet was placed in each tray containing the peeled shallots and the tray was heat sealed with the low-density polyethylene film lid. Packages were stored at either 10 or 25 ℃ for 10 d. Trays containing only peeled shallots were designated as controls. High storage temperature stimulated quality changes in the shallots. Although ethanol vapour accumulated in the active package headspace, the extent to which ethanol concentrations increased within the shallots was not significantly different from that in the control packages. Microbial proliferation in terms of yeast and mould counts could be delayed through a combination of 10 ℃ and ethanol vapour released from the low-density polyethylene sachet. The ethanol vapour accumulated in the packages did not have a significant effect on mass loss, firmness, and colour changes in the peeled shallots, or on the concentrations of oxygen and carbon dioxide in the packages.
Test and Validation of the Mars Science Laboratory Robotic Arm
NASA Technical Reports Server (NTRS)
Robinson, M.; Collins, C.; Leger, P.; Kim, W.; Carsten, J.; Tompkins, V.; Trebi-Ollennu, A.; Florow, B.
2013-01-01
The Mars Science Laboratory Robotic Arm (RA) is a key component for achieving the primary scientific goals of the mission. The RA supports sample acquisition by precisely positioning a scoop above loose regolith or accurately preloading a percussive drill on Martian rocks or rover-mounted organic check materials. It assists sample processing by orienting a sample processing unit called CHIMRA through a series of gravity-relative orientations and sample delivery by positioning the sample portion door above an instrument inlet or the observation tray. In addition the RA facilitates contact science by accurately positioning the dust removal tool, Alpha Particle X-Ray Spectrometer (APXS) and the Mars Hand Lens Imager (MAHLI) relative to surface targets. In order to fulfill these seemingly disparate science objectives the RA must satisfy a variety of accuracy and performance requirements. This paper describes the necessary arm requirement specification and the test campaign to demonstrate these requirements were satisfied.
Serologic test systems development. Progress report, July 1, 1976--September 30, 1977
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saunders, G.C.; Clinard, E.H.; Bartlett, M.L.
1978-01-01
Work has continued on the development and application of the Enzyme-Labeled Antibody (ELA) test to the USDA needs. Results on trichinosis, brucellosis, and staphylococcal enterotoxin A detection are very encouraging. A field test for trichinosis detection is being worked out in cooperation with Food Safety and Quality Service personnel. Work is in progress with the Technicon Instrument Corporation to develop a modification of their equipment to automatically process samples by the ELA procedure. An automated ELA readout instrument for 96-well trays has been completed and is being checked out.
NASA Technical Reports Server (NTRS)
Lorenz, R. D.; Kraal, E. R.; Eddlemon, E. E.; Cheney, J.; Greeley, R.
2004-01-01
The generation of waves by winds across Earth's water oceans is a topic of enduring fascination. However, the physics of the problem are rather forbidding and thus the relationships between real-world windspeed and sea state tend to be empirical. Such empirical relations are of limited utility in environments where the physical parameters are different, such as the surfaces of other planets. These environments have only recently come to oceanographers attention, with the discovery of ancient shorelines and lakes on Mars, and the prospects for and recent evidence of lakes and seas of liquid hydrocarbons on Saturn's moon Titan. We are aware of only one other published experimental wind-water tunnel study where the fluid parameters have been varied. This used artificially-generated mm-scale waves at 3.8-7.6 Hz in water, glycerol solutions (higher viscosity) and surfactant solutions (lower surface tension). Lower viscosity solutions had higher wave growth rates: surprisingly, higher surface tension led to more rapid wave growth. The liquid density was not appreciably varied, and 1 bar air was used throughout.We used the MARSWIT (Mars Wind Tunnel) operated by ASU at NASA Ames. A fiberglass tray (5 cm x 120 cm x 75 cm) was installed in the tunnel, with an approx. 1:5 ramp to prevent strong flow separation. The tray was filled to a depth of about 4 cm. Sensors were clamped to the tray itself or held by a steel and aluminium frame just above the water level. A towel was draped on the water surface at the downwind end of the tray to act as a damper to suppress wave reflection. Position-sensitive infrared (IR) reflection sensors (Sharp GP12D02) and ultrasonic rangers (Devantech DF-04) used in mobile robotics were used as water level sensors. The tray was observed with a video camera, whose output could be viewed on a monitor and recorded on VHS tape.
In vivo precision of conventional and digital methods for obtaining quadrant dental impressions.
Ender, Andreas; Zimmermann, Moritz; Attin, Thomas; Mehl, Albert
2016-09-01
Quadrant impressions are commonly used as alternative to full-arch impressions. Digital impression systems provide the ability to take these impressions very quickly; however, few studies have investigated the accuracy of the technique in vivo. The aim of this study is to assess the precision of digital quadrant impressions in vivo in comparison to conventional impression techniques. Impressions were obtained via two conventional (metal full-arch tray, CI, and triple tray, T-Tray) and seven digital impression systems (Lava True Definition Scanner, T-Def; Lava Chairside Oral Scanner, COS; Cadent iTero, ITE; 3Shape Trios, TRI; 3Shape Trios Color, TRC; CEREC Bluecam, Software 4.0, BC4.0; CEREC Bluecam, Software 4.2, BC4.2; and CEREC Omnicam, OC). Impressions were taken three times for each of five subjects (n = 15). The impressions were then superimposed within the test groups. Differences from model surfaces were measured using a normal surface distance method. Precision was calculated using the Perc90_10 value. The values for all test groups were statistically compared. The precision ranged from 18.8 (CI) to 58.5 μm (T-Tray), with the highest precision in the CI, T-Def, BC4.0, TRC, and TRI groups. The deviation pattern varied distinctly depending on the impression method. Impression systems with single-shot capture exhibited greater deviations at the tooth surface whereas high-frame rate impression systems differed more in gingival areas. Triple tray impressions displayed higher local deviation at the occlusal contact areas of upper and lower jaw. Digital quadrant impression methods achieve a level of precision, comparable to conventional impression techniques. However, there are significant differences in terms of absolute values and deviation pattern. With all tested digital impression systems, time efficient capturing of quadrant impressions is possible. The clinical precision of digital quadrant impression models is sufficient to cover a broad variety of restorative indications. Yet the precision differs significantly between the digital impression systems.
NASA Technical Reports Server (NTRS)
Vyhnal, Richard F.
1993-01-01
Long Duration Exposure Facility (LDEF) Experiment A0175 involved the non-instrumented exposure of seven carbon-fiber reinforced resin-matrix advanced composite panels contained in two trays - A7 and A1. These two trays were located, respectively, on the leading and trailing faces of LDEF, obliquely oriented to the RAM (Row 9) and WAKE (Row 3) directions. The identity and location of the seven panels, which consisted of six flat laminates of the following material systems are shown: carbon/epoxy (T300/934), carbon/bismaleimide (T300/F178), and carbon/polyimide (C6000/LARC-160 and C6000/PMR-15), plus one bonded honeycomb sandwich panel (T300/934 face sheets and Nomex core) patterned after the Space Shuttle payload bay door construction. These material systems were selected to represent a range of then-available matrix resins which, by virtue of their differing polymer chemistry, could conceivably exhibit differing susceptibility to the low-earth orbit (LEO) environment. The principal exposure conditions of the LDEF environment at these tray locations are shown. Noteworthy to some of the observations discussed is the four-orders-of magnitude difference in the atomic oxygen (AO) fluence, which made a shallow incidence angle (approximately 22 deg) to Tray A7, while Tray A1 on the trailing face was essentially shielded from AO exposure. This evaluation focused on determining the individual and relative suitability of a variety of resin-matrix composite systems for long-term space structural applications. This was accomplished primarily by measuring and comparing a range of engineering mechanical properties on over 300 test coupons sectioned from the flight panels and from identical control panels, and tested at ambient and elevated temperatures. This testing was supported by limited physical characterization, involving visual examination of flight panel surface features, measurements of weight loss and warpage, and examination for changes in internal integrity (micro cracking, delamination) by ultrasonic c-scan and polished cross-sections.
Effect of implant angulation and impression technique on impressions of NobelActive implants.
Alexander Hazboun, Gillian Brewer; Masri, Radi; Romberg, Elaine; Kempler, Joanna; Driscoll, Carl F
2015-05-01
How the configuration of the NobelActive internal conical connection affects implant impressions is uncertain. The purpose of this study was to measure the effect in vitro of closed and open tray impression techniques for NobelActive implants placed at various angulations. Six NobelActive implants were placed in a master maxillary cast as follows: 0 degrees of angulation to a line drawn perpendicular to the occlusal plane in the first molar area, 15 degrees of angulation to a line drawn perpendicular to the occlusal plane in the first premolar area, and 30 degrees of angulation to a line drawn perpendicular to the occlusal plane in the lateral incisor area. Twelve open tray and 12 closed tray impressions were made. Occlusal, lateral, and frontal view photographs of the resulting casts were used to measure the linear and angular displacement of implant analogs. Statistical analysis was performed with a factorial analysis of variance (ANOVA), followed by the Tukey HSD test (α=.05). No significant difference was found in the impressions made of NobelActive implants with the open or closed tray technique (linear displacement: F=0.93, P=.34; angular displacement: F=2.09, P=.15). In addition, implant angulation (0, 15, or 30 degrees) had no effect on the linear or angular displacement of impressions (linear displacement: F=2.72, P=.07; angular displacement: F=0.86, P=.43). Finally, no significant interaction was found between impression technique and implant angulation on NobelActive implants (F=0.25, P=.77; F=1.60, P=.20). Within the limitations of this study, impression technique (open vs closed tray) and implant angulation (0, 15, and 30 degrees) had no significant effect on in vitro impressions of NobelActive implants. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
The Aerogel Cerenkov detector for the SHMS magnetic spectrometer in Hall C at Jefferson Lab
Horn, T.; Mkrtchyan, H.; Ali, S.; ...
2016-10-28
Hadronic reactions producing strange quarks such as exclusive or semi-inclusive kaon production, play an important role in studies of hadron structure and the dynamics that bind the most basic elements of nuclear physics. The small-angle capability of the new Super High Momentum Spectrometer (SHMS) in Hall C, coupled with its high momentum reach - up to the anticipated 11-GeV beam energy in Hall C - and coincidence capability with the well-understood High Momentum Spectrometer, will allow for probes of such hadron structure involving strangeness down to the smallest distance scales to date. To cleanly select the kaons, a threshold aerogelmore » Cerenkov detector has been constructed for the SHMS. The detector consists of an aerogel tray followed by a diffusion box. Four trays for aerogel of nominal refractive indices of n=1.030, 1.020, 1.015 and 1.011 were constructed. The tray combination will allow for identification of kaons from 1 GeV/c up to 7.2 GeV/c, reaching 10 -2 proton and 10 -3 pion rejection, with kaon detection efficiency better than 95%. The diffusion box of the detector is equipped with 14 five-inch diameter photomultiplier tubes. Its interior walls are covered with Gore diffusive reflector, which is superior to the commonly used Millipore paper and improved the detector performance by 35%. The inner surface of the two aerogel trays with higher refractive index is covered with Millipore paper, however, those two trays with lower aerogel refractive index are again covered with Gore diffusive reflector for higher performance. The measured mean number of photoelectrons in saturation is ~12 for n=1.030, ~8 for n=1.020, ~10 for n=1.015, and ~5.5 for n=1.011. Here the design details, the results of component characterization, and initial performance tests and optimization of the detector are presented.« less
Peter Koch
1983-01-01
Freshly cut whole-tree hickory chips had lower moisture content (MC) initially and dried more rapidly than those of southern red oak. Such chips spread during April 1981 in roofed trays did not dry to 20 percent MC, ovendry-weight basis, faster than those spread in October 1980. In roofed trays, unturned chips spread 4 inches deep generally dried more rapidly than if...
Testing of Compounds for Efficacy against Schistosomiasis.
1987-08-25
Nostoc muscorU) has been grown (Liang, 1974) is placed in all glass aquaria, and plastic trays to serve as an additional food source. Snails in petri...supplemented with blue-green algae ( Nostoc muscoru) and mud forms the diet of stock snails in glass aquaria as well as those kept in plastic trays. The agar...green algae ( Nostoc muscorum) and water is used for rearing young * snails and maintaining both pre-patent and patent snails V (Liang, 1974); 3) a petri
1983-11-28
STS009-05-0153 (28 Nov. - 8 Dec. 1983) --- Though STS-9 was the space shuttle Columbia's sixth spaceflight, it was the first opportunity for an onboard galley, some of the results of which are shown in this 35mm scene on the flight deck. The metal tray makes for easy preparation and serving of in-space meals for crew members. This crewman is seated at the pilot's station on the flight deck. The actual galley is located in the middeck. Photo credit: NASA
1970-01-01
Shown here is the Skylab food heating and serving tray with food, drink, and utensils. The tray contained heating elements for preparing the individual food packets. The food on Skylab was a great improvement over that on earlier spaceflights. It was no longer necessary to squeeze liquified food from plastic tubes. Skylab's kitchen in the Orbital Workshop wardroom was so equipped that each crewman could select his own menu and prepare it to his own taste. The Marshall Space Flight Center had program management responsibility for the development of Skylab hardware and experiments.
A case of gamasoidosis associated with exposure to a wild lorikeet feeding tray.
Warren, Matthew; Tritton, Sara; Abbott, Nicola Cd; Sim, Sarah; Strutton, Geoffrey M; Soyer, H Peter
2016-05-01
Gamasoidosis (acariasis, avian-mite dermatitis or bird-mite dermatitis) is caused by members of the mite superfamily Dermanyssoidea. The mites lay their eggs on the nest of the birds they feed on. The also leave the nest and feed on humans if there is no bird host available. The bites result in urticated plaques and papules. Here we present a case of gamasoidosis from exposure to a wild lorikeet feeding tray. © 2015 The Australasian College of Dermatologists.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., titrate the solution back to the original exact pH using 0.100 N HCl. Record the milliliters of HCl used... trays (small cubes). 2.2Materials Required. 2.2.1Ice cubes (made with distilled water). 2.2.2A solution... (two trays of cubes). 2.3.2Put 70 cubic centimeters (cc) of 1 M Na2SO3 solution into a 400-mL beaker...
Code of Federal Regulations, 2013 CFR
2013-07-01
..., titrate the solution back to the original exact pH using 0.100 N HCl. Record the milliliters of HCl used... trays (small cubes). 2.2Materials Required. 2.2.1Ice cubes (made with distilled water). 2.2.2A solution... (two trays of cubes). 2.3.2Put 70 cubic centimeters (cc) of 1 M Na2SO3 solution into a 400-mL beaker...
Code of Federal Regulations, 2012 CFR
2012-07-01
..., titrate the solution back to the original exact pH using 0.100 N HCl. Record the milliliters of HCl used... trays (small cubes). 2.2Materials Required. 2.2.1Ice cubes (made with distilled water). 2.2.2A solution... (two trays of cubes). 2.3.2Put 70 cubic centimeters (cc) of 1 M Na2SO3 solution into a 400-mL beaker...
1986-02-01
precooked frozen packed foods; (2) shelf life of Tray Pack vs. the no. 10 can at ambient and stressful storage temperatures; (3) changes in nutrient...bacteriological tests to certify safety for human consumption. Both Natick RD&E Center and Kraft products were subjected to 9 I...heat processed products that were storage temperature stressed at 380 C, QS data indicated that expected storage life of seven of the CC products was
Dorsey, John H; Carmona-Galindo, Víctor D; Leary, Christopher; Huh, Julie; Valdez, Jennifer
2013-03-01
A study was performed in Del Rey Lagoon, City of Los Angeles, to determine if the lagoon was as a source or sink for fecal indicator bacteria (FIB: total coliforms, Escherichia coli, enterococci) and to screen for the presence of other potentially pathogenic bacteria. The lagoon receives tidal flows from the adjacent Ballona Estuary whose water usually is contaminated with FIB originating from the highly urbanized Ballona Creek Watershed. During 16 sampling events from February 2008 through March 2009, replicate water samples (n = 3) were collected 1 h prior to the high tide and 1 h prior to the following low tide. FIB concentrations were measured by the defined substrate method (IDEXX, Westbrook, Me) followed by culturing of bacterial isolates sampled from positive IDEXX Quanti-Tray wells and were identified using the Vitek 2 Compact (bioMérieux, Durham, NC). Mean concentrations of FIB often differed by an order of magnitude from flood to ebb flow conditions. The lagoon tended to act as a sink for total coliforms based on the ratio of mean flood to ebb densities (R (F/E)) >1.0 during 56 % of the sampling events and during ebb flows, as a source for E. coli and enterococci (R (F/E) <1.69 % of events). Approximately 54 species were identified from 277 isolates cultured from the IDEXX Quanti-Trays. Of these, 54 % were species known to include pathogenic strains that can be naturally occurring, introduced in runoff, or originated from other sources. Diversity and cluster analyses indicated a dynamic assemblage that changes in species composition with day-to-day fluctuations as well as tidal action. The concept of monitoring the lagoon and estuary as a sentinel habitat for pathogenic assemblages is discussed.
EXPOSE-R on Mission on the ISS
NASA Astrophysics Data System (ADS)
Panitz, Corinna; Rabbow, Elke; Rettberg, Petra; Barczyk, Simon; Kloss, Maria; Reitz, Guenther
Currently EXPOSE-R is on mission! This astrobiological exposure facility was accommodated at the universal workplace URM-D Zenith payload site, located outside the Russian Svezda Module of the International Space Station (ISS) by extravehicular activity (EVA) on March 10th 2009. It contains 3 trays accommodating 12 sample compartments with sample carriers in three levels either open to space vacuum or kept in a defined gas environment. In its 8 experiments of biological and chemical content, more than 1200 individual samples are exposed to solar ultraviolet (UV) radiations, vacuum, cosmic rays or extreme temperature variations. In their different experiments the involved scientists are studying the question of life's origin on Earth and the results of their experiments are contributing to different aspects of the evolution and distribution of life in the Universe. Additionally integrated into the EXPOSE-R facility are several dosimeters monitoring the ionising and the solar UV-radiation during the mission to deliver useful information to complement the sample analysis. In close cooperation with the DLR and the Technical University Munich (TUM), the Rheinisch -Westfülische Technischen Hochschule Aachen (RWTH Aachen) operates the experiment "Spores". a This is one of the 6 astrobiological experiments of the ROSE-Consortium" (Response of Or-ganisms to Space Environment) of the EXPOSE-R mission. In these experiments spores of bacteria, fungi and ferns are being over layered or mixed with meteorite material. The analysis of the effect of the space parameters on different biological endpoints of the spores of the mi-croorganism Bacillus subtilis will be performed after the retrieval of the experiment scheduled for the end of 2010. Parallel to the space mission an identical set of samples was accommodated into EXPOSE-R trays identical in construction to perform the Mission Ground Reference (MGR) Test. Currently this MGR Test is carried out in the Planetary and Space Simulation Facilities (PSI) of DLR, Cologne: the space parameters (vacuum, temperature and extra-terrestrial UV-radiation) as delivered from the ISS are simulated. An overview over the EXPOSE mission from the EXPOSE-R Experiment Verification Test (EVT) Program to the flight sample preparation is presented.
Reusable, tamper-indicating seal
Ryan, Michael J.
1978-01-01
A reusable, tamper-indicating seal comprises a drum confined within a fixed body and rotatable in one direction therewithin, the top of the drum constituting a tray carrying a large number of small balls of several different colors. The fixed body contains parallel holes for looping a seal wire therethrough. The base of the drums carries cams adapted to coact with cam followers to lock the wire within the seal at one angular position of the drum. A channel in the fixed body -- visible from outside the seal -- adjacent the tray constitutes a segregated location for a small plurality of the colored balls. A spring in the tray forces colored balls into the segregated location at one angular position of the drum, further rotation securing the balls in position and the wires in the seal. A wedge-shaped plough removes the balls from the segregated location, at a different angular position of the drum, the wire being unlocked at the same position. A new pattern of colored balls will appear in the segregated location when the seal is relocked.
NASA Astrophysics Data System (ADS)
Mohan, S. Mariraj
2017-12-01
In this study, it was aimed for effective utilization of paper mill sludge through vermicomposting by varying seed proportion with sp. Eisenia fetida. Nine plastic trays were used for the experimental work including control. Different seed proportions of cow dung and cattle dung were tested. The multiplication of earthworms in terms of number was counted at the end of vermicomposting. The N, K, Ca, Na values of the manure in each vermibin were estimated before and after vermicomposting. In this study, it was concluded that tray A2 which has combination of 75% Cow dung (CD) and 25% Paper Mill Sludge (PMS) provided better nitrogen synthesis and lowering C/N ratio, whereas tray A4 (25%CD + 75% PMS) yielded better Calcium recovery. Both the seed materials were found to be suitable for Potassium recovery. From this study, it was inferred that vermicomposting of paper mill sludge with sp. Eisenia fetida along with seed materials can also solve the problem of disposal of this sludge.
In-Situ Operations and Planning for the Mars Science Laboratory Robotic Arm: The First 200 Sols
NASA Technical Reports Server (NTRS)
Robinson, M.; Collins, C.; Leger, P.; Carsten, J.; Tompkins, V.; Hartman, F.; Yen, J.
2013-01-01
The Robotic Arm (RA) has operated for more than 200 Martian solar days (or sols) since the Mars Science Laboratory rover touched down in Gale Crater on August 5, 2012. During the first seven months on Mars the robotic arm has performed multiple contact science sols including the positioning of the Alpha Particle X-Ray Spectrometer (APXS) and/or Mars Hand Lens Imager (MAHLI) with respect to rocks or loose regolith targets. The RA has supported sample acquisition using both the scoop and drill, sample processing with CHIMRA (Collection and Handling for In- Situ Martian Rock Analysis), and delivery of sample portions to the observation tray, and the SAM (Sample Analysis at Mars) and CHEMIN (Chemistry and Mineralogy) science instruments. This paper describes the planning and execution of robotic arm activities during surface operations, and reviews robotic arm performance results from Mars to date.
The use of 3D-printed titanium mesh tray in treating complex comminuted mandibular fractures
Ma, Junli; Ma, Limin; Wang, Zhifa; Zhu, Xiongjie; Wang, Weijian
2017-01-01
Abstract Rationale: Precise bony reduction and reconstruction of optimal contour in treating comminuted mandibular fractures is very difficult using traditional techniques and devices. The aim of this report is to introduce our experiences in using virtual surgery and three-dimensional (3D) printing technique in treating this clinical challenge. Patient concerns: A 26-year-old man presented with severe trauma in the maxillofacial area due to fall from height. Diagnosis: Computed tomography images revealed middle face fractures and comminuted mandibular fracture including bilateral condyles. Interventions and outcomes: The computed tomography data was used to construct the 3D cranio-maxillofacial models; then the displaced bone fragments were virtually reduced. On the basis of the finalized model, a customized titanium mesh tray was designed and fabricated using selective laser melting technology. During the surgery, a submandibular approach was adopted to repair the mandibular fracture. The reduction and fixation were performed according to preoperative plan, the bone defects in the mental area were reconstructed with iliac bone graft. The 3D-printed mesh tray served as an intraoperative template and carrier of bone graft. The healing process was uneventful, and the patient was satisfied with the mandible contour. Lessons: Virtual surgical planning combined with 3D printing technology enables surgeon to visualize the reduction process preoperatively and guide intraoperative reduction, making the reduction less time consuming and more precise. 3D-printed titanium mesh tray can provide more satisfactory esthetic outcomes in treating complex comminuted mandibular fractures. PMID:28682875
Cassegrain Solar Concentrator System for ISRU Material Processing
NASA Technical Reports Server (NTRS)
Colozza, Anthony J.; Macosko, Robert; Castle, Charles; Sacksteder, Kurt; Suzuki, Nantel H.; Mulherin, James
2012-01-01
A 0.5 m diameter Cassegrain concentrator was constructed as a means of providing highly concentrated sunlight for the demonstration processing of lunar simulated regolith and other NASA In-Situ Resource Utilization Project (ISRU) reaction processes. The concentrator is constructed of aluminum with a concentration ratio of approximately 3000 to 1. The concentrator focuses solar energy into a movable tray located behind the concentrator. This tray can hold simulated regolith or any other material and or device to be tested with concentrated solar energy. The tray is movable in one axis. A 2-axis extended optical system was also designed and fabricated. The extended optical system is added to the back of the primary concentrator in place of the moveable test tray and associated apparatus. With this optical system the focused sunlight can be extended from the back of the primary concentrator toward the ground with the added advantage of moving the focal point axially and laterally relative to the ground. This allows holding the focal point at a fixed position on the ground as the primary concentrator tracks the sun. Also, by design, the focal point size was reduced via the extended optics by a factor of 2 and results in a concentration ratio for the system of approximately 6,000 to 1.The designs of both optical systems are discussed. The results from simulated regolith melting tests are presented as well as the operational experience of utilizing the Cassegrain concentrator system.
Gutierrez, Michele Mario; Meleddu, Marta; Piga, Antonio
2017-01-01
Packaging is associated with a high environmental impact. This is also the case in the food industry despite packaging being necessary for maintaining food quality, safety assurance and preventing food waste. The aim of the present study was to identify improvements in food packaging solutions able to minimize environmental externalities while maximizing the economic sustainability. To this end, the life cycle assessment (LCA) methodology was applied to evaluate the environmental performance of new packaging solutions. The environmental impact of packaging and food losses and the balance between the two were examined in relation to a cheesecake that is normally packaged in low density polyethylene film and has a limited shelf life due to microbial growth. A shelf life extension was sought via application of the well-established modified atmosphere packaging (MAP) technique. Samples for MAP (N 2 /CO 2 : 70/30) were placed inside multilayer gas barrier trays, which were then wrapped with a multilayer gas and water barrier film (i.e. AerPack packaging); control batches were packaged in gas barrier recycled polyethylene terephthalate (XrPet) trays and wrapped with a XrPet film. Samples were then stored at 20°C and inspected at regular intervals for chemical-physical, microbiological and sensory parameters. Results show that the new packaging solution could considerably extend the shelf life of cheesecakes, thereby reducing food waste and decreasing the overall environmental impact. Moreover, the new packaging allows one to minimize transport costs and to generate economies of scale in manufacturing. Copyright © 2016 Elsevier Ltd. All rights reserved.
THz - ToF Optical Layer Analysis (OLA) to determine optical properties of dielectric materials
NASA Astrophysics Data System (ADS)
Spranger, Holger; Beckmann, Jörg
2017-02-01
Electromagnetic waves with frequencies between 0.1 and 10 THz are described as THz-radiation (T-ray). The ability to penetrate dielectric materials makes T-rays attractive to reveal discontinuities in polymer and ceramic materials. THz-Time Domain Spectroscopy Systems (THz-TDS) are available on the market today which operates with THz-pulses transmitted and received by optically pumped semiconductor antennas. In THz-TDS the travelling time (ToF) and shape of the pulse is changed if it interacts with the dielectric material and its inherent discontinuities. A tomogram of the object under the test can be reconstructed from time of flight diffraction (ToFD) scans if a synthetic focusing aperture (SAFT) algorithm is applied. The knowledge of the base materials shape and optical properties is essential for a proper reconstruction result. To obtain these properties a model is assumed which describes the device under the test as multilayer structure composed of thin layers with different dielectric characteristics. The Optical Layer Analysis (OLA) is able to fulfill these requirements. A short description why the optical properties are crucial for meaningful SAFT reconstruction results will be given first. Afterwards the OLA will be derived and applied on representative samples to discuss and evaluate its benefits and limits.
Yilmaz, I; Demirci, M
2010-06-01
The objective of this research was to determine physicochemical changes and microbiological quality of the different packaged meatball samples. Meatball samples in polystyrene tray were closed with polyethylene film (PS packs), vacuumed and modified atmosphere packaged, (MAP) (65% N(2), 35% CO(2)), and held under refrigerated display (4 °C) for 8, 16 and 16 days for PS packs, vacuum and MAP, respectively. Microbial load, free fatty acids and thiobarbituric acid values of the samples tended to increase with storage time. Bacteria counts of the raw meatball samples increased 2 log cycles at the end of storage compared with initial values. Meatball samples can be stored without any microbiological problem for 7 days at 4 °C. Results from this study suggested that shelf-life assigned to modified-MAP and vacuum-packed meatballs may be appropriate. Meatball samples underwent physical deformation when they were packed before vacuum process. With these negative factors considered, MAP is superior to other two packs methods.
Selecman, Audrey M; Wicks, Russell A
2009-03-01
An implant-level impression is often desired for designing and fabricating an implant-supported fixed restoration, especially when 2 or more implants have been placed. However, convergent implants placed too close in proximity pose several problems, starting with the impression. In situations of extreme convergence or close proximity, modification of conventional metal copings may be impossible. This clinical report describes the use and associated advantages and disadvantages of solid plastic, press-fit, closed-tray impression copings as a mechanism suitable to create an implant-level cast.
Combat Ration Network for Technology Implementation. Universal Benchtop Package Tester
2006-10-01
of three years of shelf life, but this packaging is susceptible to tears and holes during the manufacturing process. To avoid package integrity...characteristics, cannot provide a measurement of container contents. April 2003 - Precision Automation and PTI-USA expressed interest in manufacturing systems to... Noodles (185cc) • 212cc(+14.6%) • 209cc(+13.0%) – Chicken Brst. (150cc) • 160cc(+6.3%) • 154cc(+2.6%) • Water Trays – Tray A4 (185cc) • 200cc(+8.1
2010-01-01
were then hatched in aluminum trays Þlled with deionized water. The larvae were provided a diet of VitaPro Plus Þsh food and brewerÕs yeast at a 2:1...deionized water, left overnight, and transferred to a plastic tray containing distilled water. A powdered diet (2:1 pot belly pig chow:brewerÕs yeast... powdered diet every other day. DMSO equivalents were used as the con- trol. The number of living and dead larvae was counted 72 h after the start of
To develop a flying fish egg inspection system by a digital imaging base system
NASA Astrophysics Data System (ADS)
Chen, Chun-Jen; Jywe, Wenyuh; Hsieh, Tung-Hsien; Chen, Chien Hung
2015-07-01
This paper develops an automatic optical inspection system for flying fish egg quality inspection. The automatic optical inspection system consists of a 2-axes stage, a digital camera, a lens, a LED light source, a vacuum generator, a tube and a tray. This system can automatically find the particle on the flying egg tray and used stage to driver the tube onto the particle. Then use straw and vacuum generator to pick up the particle. The system pick rate is about 30 particles per minute.
Profiles in garbage: Polyethylene terephthalate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, C.
1997-11-01
Polyethylene terephthalate (PET) is a plastic resin used primarily to make bottles. Soft drinks -- along with salad dressing, fruit juices, peanut butter, and other household and consumer products -- use PET bottles. PET also is used for film, sheeting for cups and food trays, oven-safe trays, and other uses. PET is a relatively new packaging resin, first commercialized in the early 1970s. Because it is an ``engineered`` resin, PET is more expensive than commodity resins such as high-density polyethylene (HDPE) and, for the same reason, it is usually the highest valued plastic recyclable.
The Aerogel Čerenkov detector for the SHMS magnetic spectrometer in Hall C at Jefferson Lab
NASA Astrophysics Data System (ADS)
Horn, T.; Mkrtchyan, H.; Ali, S.; Asaturyan, A.; Carmignotto, M.; Dittmann, A.; Dutta, D.; Ent, R.; Hlavin, N.; Illieva, Y.; Mkrtchyan, A.; Nadel-Turonski, P.; Pegg, I.; Ramos, A.; Reinhold, J.; Sapkota, I.; Tadevosyan, V.; Zhamkochyan, S.; Wood, S. A.
2017-01-01
Hadronic reactions producing strange quarks such as the exclusive p (e , e ‧K+) Λ and p (e , e ‧K+)Σ0 reactions, or the semi-inclusive p (e , e ‧K+) X reaction, play an important role in studies of hadron structure and the dynamics that bind the most basic elements of nuclear physics. The small-angle capability of the new Super High Momentum Spectrometer (SHMS) in Hall C, coupled with its high momentum reach - up to the anticipated 11-GeV beam energy in Hall C - and coincidence capability with the well-understood High Momentum Spectrometer (HMS), will allow for probes of such hadron structure involving strangeness down to the smallest distance scales to date. To cleanly select the kaons, a threshold aerogel Cerenkov detector has been constructed for the SHMS. The detector consists of an aerogel tray followed by a diffusion box. Four trays for aerogel of nominal refractive indices of n=1.030, 1.020, 1.015 and 1.011 were constructed. The tray combination will allow for identification of kaons from 1 GeV/c up to 7.2 GeV/c, reaching ∼10-2 proton and 10-3 pion rejection, with kaon detection efficiency better than 95%. The diffusion box of the detector is equipped with 14 five-inch diameter photomultiplier tubes. Its interior walls are covered with Gore diffusive reflector, which is superior to the commonly used Millipore paper and improved the detector performance by 35%. The inner surface of the two aerogel trays with higher refractive index is covered with Millipore paper, however, those two trays with lower aerogel refractive index are again covered with Gore diffusive reflector for higher performance. The measured mean number of photoelectrons in saturation is ∼12 for n=1.030, ∼8 for n=1.020, ∼10 for n=1.015, and ∼5.5 for n=1.011. The design details, the results of component characterization, and initial performance tests and optimization of the detector are presented.
Development of an integrated, unattended assay system for LWR-MOX fuel pellet trays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stewart, J.E.; Hatcher, C.R.; Pollat, L.L.
1994-08-01
Four identical unattended plutonium assay systems have been developed for use at the new light-water-reactor mixed oxide (LWR-MOX) fuel fabrication facility at Hanau, Germany. The systems provide quantitative plutonium verification for all MOX pellet trays entering or leaving a large, intermediate store. Pellet-tray transport and storage systems are highly automated. Data from the ``I-Point`` (information point) assay systems will be shared by the Euratom and International Atomic Energy Agency (IAEA) Inspectorates. The I-Point system integrates, for the first time, passive neutron coincidence counting (NCC) with electro-mechanical sensing (EMS) in unattended mode. Also, provisions have been made for adding high-resolution gammamore » spectroscopy. The system accumulates data for every tray entering or leaving the store between inspector visits. During an inspection, data are analyzed and compared with operator declarations for the previous inspection period, nominally one month. Specification of the I-point system resulted from a collaboration between the IAEA, Euratom, Siemens, and Los Alamos. Hardware was developed by Siemens and Los Alamos through a bilateral agreement between the German Federal Ministry of Research and Technology (BMFT) and the US DOE. Siemens also provided the EMS subsystem, including software. Through the USSupport Program to the IAEA, Los Alamos developed the NCC software (NCC COLLECT) and also the software for merging and reviewing the EMS and NCC data (MERGE/REVIEW). This paper describes the overall I-Point system, but emphasizes the NCC subsystem, along with the NCC COLLECT and MERGE/REVIEW codes. We also summarize comprehensive testing results that define the quality of assay performance.« less
Jo, Ayami; Kanazawa, Manabu; Sato, Yusuke; Iwaki, Maiko; Akiba, Norihisa; Minakuchi, Shunsuke
2015-08-01
To compare the effect of conventional complete dentures (CD) fabricated using two different impression methods on patient-reported outcomes in a randomized controlled trial (RCT). A cross-over RCT was performed with edentulous patients, required maxillomandibular CDs. Mandibular CDs were fabricated using two different methods. The conventional method used a custom tray border moulded with impression compound and a silicone. The simplified used a stock tray and an alginate. Participants were randomly divided into two groups. The C-S group had the conventional method used first, followed by the simplified. The S-C group was in the reverse order. Adjustment was performed four times. A wash out period was set for 1 month. The primary outcome was general patient satisfaction, measured using visual analogue scales, and the secondary outcome was oral health-related quality of life, measured using the Japanese version of the Oral Health Impact Profile for edentulous (OHIP-EDENT-J) questionnaire scores. Twenty-four participants completed the trial. With regard to general patient satisfaction, the conventional method was significantly more acceptable than the simplified. No significant differences were observed between the two methods in the OHIP-EDENT-J scores. This study showed CDs fabricated with a conventional method were significantly more highly rated for general patient satisfaction than a simplified. CDs, fabricated with the conventional method that included a preliminary impression made using alginate in a stock tray and subsequently a final impression made using silicone in a border moulded custom tray resulted in higher general patient satisfaction. UMIN000009875. Copyright © 2015 Elsevier Ltd. All rights reserved.
Beck, Bert; Spanoghe, Pieter; Moens, Maurice; Brusselman, Eva; Temmerman, Femke; Pollet, Sabien; Nuyttens, David
2014-05-01
The potential of the entomopathogenic nematode (EPN) Steinernema feltiae Filipjev as a biocontrol agent against the cabbage maggot Delia radicum (L.), was assessed in three field tests, focusing on EPN dosage, application technique and timing. Spraying cabbage plant trays with different doses of infective juveniles (IJs) (50,000, 100,000 and 200,000 per plant) generated a similar reduction of plant mortality. Spraying plant trays with 200,000 IJs of Steinernema feltiae per plant temporarily reduced the number of maggots around the plants' roots, while neither spraying a lower dose (50,000 IJs/plant) nor soil drenching with 200,000 or 50,000 IJs/plant) reduced maggot numbers. When applied as a plant tray spray, IJs of S. feltiae took 1-2 weeks to spread through the soil surrounding the roots. The pathogenicity of the EPNs, as evaluated by a Galleria mellonella bait test, was highest (up to 100% mortality) until up to five weeks after application, and declined to control levels after 4-7 weeks. Follow-up drench applications with EPNs, applied one and/or two weeks after the first EPN application, did not influence control of Delia radicum. Plant tray spraying provides better placement of Steinernema feltiae than soil drench treatments for control of Delia radicum. Plant mortality was not dose-dependent in the presented trials, unlike the reduction of maggot numbers. Further research into timing and application technique of follow-up treatments with S. feltiae is required to increase efficacy to commercial standards. © 2013 Society of Chemical Industry.
Bernhardt, Kathie A; Beck, Lisa A; Lamb, Jeffry L; Kaufman, Kenton R; Amin, Shreyasee; Wuermser, Lisa-Ann
2012-04-01
The aim of the study was to determine the proportion of body weight borne through the lower limbs in persons with complete motor paraplegia using a standing frame, with and without the support of their arms. We also examined the effect of low-magnitude whole-body vibration on loads borne by the lower limbs. Vertical ground reaction forces (GRFs) were measured in 11 participants (six men and five women) with paraplegia of traumatic origin (injury level T3-T12) standing on a low-magnitude vibrating plate using a standing frame. GRFs were measured in four conditions: (1) no vibration with arms on standing frame tray, (2) no vibration with arms at side, (3) vibration with arms on tray, and (4) vibration with arms at side. GRF with arms on tray, without vibration, was 0.76 ± 0.07 body weight. With arms at the side, GRF increased to 0.85 ± 0.12 body weight. With vibration, mean GRF did not significantly differ from no-vibration conditions for either arm positions. Oscillation of GRF with vibration was significantly different from no-vibration conditions (P < 0.001) but similar in both arm positions. Men and women with paraplegia using a standing frame bear most of their weight through their lower limbs. Supporting their arms on the tray reduces the GRF by approximately 10% body weight. Low-magnitude vibration provided additional oscillation of the load-bearing forces and was proportionally similar regardless of arm position.
Bernhardt, Kathie A.; Beck, Lisa A.; Lamb, Jeffry L.; Kaufman, Kenton R.; Amin, Shreyasee; Wuermser, Lisa-Ann
2014-01-01
Objective To determine the proportion of body weight (BW) borne through the lower limbs in persons with complete, motor paraplegia using a standing frame, with and without support of their arms. We also examined the effect of low-magnitude whole body vibration on loads borne by the lower extremities. Design Vertical ground reaction forces (GRF) were measured in 11 participants (6 men and 5 women) with paraplegia of traumatic origin (injury level T3 to T12) standing on a low-magnitude vibrating plate using a standing frame. GRF were measured in four conditions: 1) no vibration with arms on standing frame tray; 2) no vibration with arms at side; 3) vibration with arms on tray; 4) vibration with arms at side. Results GRF with arms on tray, without vibration, was 0.76 ± 0.07 BW. With arms at the side, GRF increased to 0.85 ± 0.12 BW. With vibration, mean GRF did not significantly differ from no-vibration conditions for either arm positions. Oscillation of GRF with vibration was significantly different from no-vibration conditions (p<0.001) but similar in both arm positions. Conclusion Men and women with paraplegia using a standing frame bear the majority of their weight through their lower limbs. Supporting their arms on the tray reduces the GRF by ~10% BW. Low-magnitude vibration provided additional oscillation of the load-bearing forces and was proportionally similar regardless of arm position. PMID:22407161
Environmental cell assembly for use in for use in spectroscopy and microscopy applications
Stowe, Ashley Clinton; Smyrl, Norman; Hallman, Jr., Russell L.
2014-09-02
An environmental cell assembly for use in microscopy and spectroscopy applications, including: an environmentally sealed body assembly configured to selectively hold and contain a sample; a plurality of ports manufactured into one or more surfaces of the body assembly for one or more of evacuating the body assembly and injecting a gas into or removing a gas from the body assembly; a port manufactured into a surface of the body assembly for receiving a translating stage configured to move the sample within the body assembly; and a port manufactured into a surface of the body assembly for receiving one or more lenses utilized in a microscopy or spectroscopy application; wherein the one or more lenses are disposed adjacent the sample without intervening structures disposed there between. The cell assembly also includes a port manufactured into a surface of the body assembly for retaining a window and providing visualization of the sample.
Characterization of terahertz waves on foreign materials of composite materials
NASA Astrophysics Data System (ADS)
Im, Kwang-Hee; Kim, Sun-Kyu; Chiou, Chien-Ping; Jung, Jong-An
2018-04-01
Carbon-fiber reinforced plastics (CFRP) are widely utilized due to their comparatively high performance in engineering structures. It is well understood that a nondestructive technique would be very beneficial. A new terahertz radiation has been recognized for its importance in technological applications. Recently, T-ray (terahertz ray) advances in technology and instrumentation have provided a probing field on the electromagnetic spectrum. In carbon composites, the penetration characterization of T-ray waves was fundamentally investigated in order to measure the painting thickness. Also, another study dealt with THz scan images of honeycomb sandwich composite panels using a refractive index (n), an absorption coefficient (α), the electrical conductivity of glass fiber embedded epoxy matrix composites, and carbon fiber reinforced plastics (CFRP) skin. For experiments, a method of detecting FRP composites with impact damage is presented, which utilizes aluminum wires intertwined with woven carbon fibers as they are inserted into the surface of the CFRP honeycomb sandwich panels. Intensive characterization of T-ray for the nondestructive evaluation (NDE) of carbon composite reinforced plastics (CFRP) composites is discussed in relation to the E-field influence with CFRP composite laminates.
NASA Technical Reports Server (NTRS)
Bernhard, Ronald P.; Zolensky, Michael E.
1994-01-01
The Long Duration Exposure Facility (LDEF) was placed in low-Earth orbit (LEO) in 1984 and recovered 5.7 years later. The LDEF was host to several individual experiments specifically designed to characterize critical aspects of meteoroid and debris environment in LEO. However, it was realized from the beginning that the most efficient use of the satellite would be to examine the entire surface for impact features. In this regard, particular interest centered on common exposed materials that faced in all LDEF pointing directions. Among the most important of these materials was the tray clamps. Therefore, in an effort to better understand the nature of particulates in LEO and their effects on spacecraft hardware, residues found in impact features on LDEF tray clamp surfaces are being analyzed. This catalog presents all data from clamps from Bay B of the LDEF. NASA Technical Memorandum 104759 has cataloged impacts that occurred on Bay B (published March 1993). Subsequent catalogs will include clamps from succeeding bays of the satellite.
Anishaparvin, A; Chhanwal, N; Indrani, D; Raghavarao, K S M S; Anandharamakrishnan, C
2010-01-01
A computational fluid dynamics (CFD) model was developed for bread-baking process in a pilot-scale baking oven to find out the effect of hot air distribution and placement of bread on temperature and starch gelatinization index of bread. In this study, product (bread) simulation was carried out with different placements of bread. Simulation results were validated with experimental measurements of bread temperature. This study showed that nonuniform air flow pattern inside the oven cavity leads to uneven temperature distribution. The study with respect to placement of bread showed that baking of bread in upper trays required shorter baking time and gelatinization index compared to those in the bottom tray. The upper tray bread center reached 100 °C at 1200 s, whereas starch gelatinization completed within 900 s, which was the minimum baking index. Moreover, the heat penetration and starch gelatinization were higher along the sides of the bread as compared to the top and bottom portions of the bread. © 2010 Institute of Food Technologists®
Industrial production of 131I by neutron irradiation and melting of sintered TeO2
NASA Astrophysics Data System (ADS)
Alanis, Jose; Navarrete, Manuel
2001-07-01
Optimal conditions of temperature and reaction rate have been settled to produce high purity TeO2 by the chemical reaction between Te and HNO3. Also, heating and time conditions for sintering this product have been found, in order to create cavities in the crystal inside, where a gaseous element such as iodine can be adsorbed with minimal leaking. In this way it is fabricated a suitable target to be irradiated with thermal neutrons for obtaining 131Te(t1/2=24.8 m) and 131mTe(t1/2=30 h) by (n, γ) nuclear reactions. Irradiation time has been chosen to get 131Te saturation activity (ti=150 m) because much longer irradiation times do not increase significantly total activity. Since parents 131Te and 131mTe have shorter half life than daughter 131I(t1/2=8.05 d) optimal cooling time must permit daughter activity to grow up till a maximum (tc=4d). Then, sintered cylinder shaped radioactive sample is manipulated in a hot cell, transported and put on a quartz tray, keeping Health Physics regulations. The quartz tray is inside a small electric oven enclosed in an airtight box with negative pressure (water 0.5 cm). There, it is gradually heated till melting point (733 °C). From 400 °C on, vapors are pumped out and bubbled in two solutions: one is 0.1 M NaOH, which retains nearly 99.9% of pumped 131I. Other is 0.02 M Na2CO3 (60%) plus 0.0025 M NaHCO3 (40%), which retains the remaining sample residue. Air filtering is accomplished by activated carbon and alumina filters in the inflow, glass wool fiber before bubbling, and activated carbon again in the outflow.
Surface characterization of LDEF materials
NASA Astrophysics Data System (ADS)
Wightman, J. P.; Grammer, Holly Little
1993-10-01
The NASA Long Duration Exposure Facility (LDEF), a passive experimental satellite, was placed into low-Earth orbit by the Shuttle Challenger in Apr. 1984. The LDEF spent an unprecedented 69 months in space. The flight and recovery of the LDEF provided a wealth of information on the longterm space environmental effects of a variety of materials exposed to the low-Earth orbit environment. Surface characterization of LDEF materials included polymers, composites, thermal control paints, and aluminum. X-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy (AES), scanning electron microscopy (SEM), and contact angle analysis were used to document changes in both the surface composition and surface chemistry of these materials. Detailed XPS analysis of the polymer systems, such as Kapton, polyimide polysiloxane copolymers, and fluorinated ethylene propylene thermal blankets on the backside of the LDEF revealed significant changes in both the surface composition and surface chemistry as a result of exposure to the low-Earth orbit environment. Polymer systems such as Kapton, polyimide polysiloxane copolymers, and polysulfone showed a common trend of decreasing carbon content and increasing oxygen content with respect to the control sample. Carbon 1s curve fit XPS analysis of the composite samples, in conjunction with SEM photomicrographs, revealed significant ablation of the polymer matrix resin to expose the carbon fibers of the composite during exposure to the space environment. Surface characterization of anodized aluminum tray clamps, which were located at regular intervals over the entire LDEF frame, provided the first results to evaluate the extent of contamination with respect to position on the LDEF. The XPS results clearly showed that the amount and state of both silicon and fluorine contamination were directly dependent upon the position of the tray clamp on the LDEF.
Surface characterization of LDEF materials
NASA Technical Reports Server (NTRS)
Wightman, J. P.; Grammer, Holly Little
1993-01-01
The NASA Long Duration Exposure Facility (LDEF), a passive experimental satellite, was placed into low-Earth orbit by the Shuttle Challenger in Apr. 1984. The LDEF spent an unprecedented 69 months in space. The flight and recovery of the LDEF provided a wealth of information on the longterm space environmental effects of a variety of materials exposed to the low-Earth orbit environment. Surface characterization of LDEF materials included polymers, composites, thermal control paints, and aluminum. X-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy (AES), scanning electron microscopy (SEM), and contact angle analysis were used to document changes in both the surface composition and surface chemistry of these materials. Detailed XPS analysis of the polymer systems, such as Kapton, polyimide polysiloxane copolymers, and fluorinated ethylene propylene thermal blankets on the backside of the LDEF revealed significant changes in both the surface composition and surface chemistry as a result of exposure to the low-Earth orbit environment. Polymer systems such as Kapton, polyimide polysiloxane copolymers, and polysulfone showed a common trend of decreasing carbon content and increasing oxygen content with respect to the control sample. Carbon 1s curve fit XPS analysis of the composite samples, in conjunction with SEM photomicrographs, revealed significant ablation of the polymer matrix resin to expose the carbon fibers of the composite during exposure to the space environment. Surface characterization of anodized aluminum tray clamps, which were located at regular intervals over the entire LDEF frame, provided the first results to evaluate the extent of contamination with respect to position on the LDEF. The XPS results clearly showed that the amount and state of both silicon and fluorine contamination were directly dependent upon the position of the tray clamp on the LDEF.
A Mars Sample Return Sample Handling System
NASA Technical Reports Server (NTRS)
Wilson, David; Stroker, Carol
2013-01-01
We present a sample handling system, a subsystem of the proposed Dragon landed Mars Sample Return (MSR) mission [1], that can return to Earth orbit a significant mass of frozen Mars samples potentially consisting of: rock cores, subsurface drilled rock and ice cuttings, pebble sized rocks, and soil scoops. The sample collection, storage, retrieval and packaging assumptions and concepts in this study are applicable for the NASA's MPPG MSR mission architecture options [2]. Our study assumes a predecessor rover mission collects samples for return to Earth to address questions on: past life, climate change, water history, age dating, understanding Mars interior evolution [3], and, human safety and in-situ resource utilization. Hence the rover will have "integrated priorities for rock sampling" [3] that cover collection of subaqueous or hydrothermal sediments, low-temperature fluidaltered rocks, unaltered igneous rocks, regolith and atmosphere samples. Samples could include: drilled rock cores, alluvial and fluvial deposits, subsurface ice and soils, clays, sulfates, salts including perchlorates, aeolian deposits, and concretions. Thus samples will have a broad range of bulk densities, and require for Earth based analysis where practical: in-situ characterization, management of degradation such as perchlorate deliquescence and volatile release, and contamination management. We propose to adopt a sample container with a set of cups each with a sample from a specific location. We considered two sample cups sizes: (1) a small cup sized for samples matching those submitted to in-situ characterization instruments, and, (2) a larger cup for 100 mm rock cores [4] and pebble sized rocks, thus providing diverse samples and optimizing the MSR sample mass payload fraction for a given payload volume. We minimize sample degradation by keeping them frozen in the MSR payload sample canister using Peltier chip cooling. The cups are sealed by interference fitted heat activated memory alloy caps [5] if the heating does not affect the sample, or by crimping caps similar to bottle capping. We prefer cap sealing surfaces be external to the cup rim to prevent sample dust inside the cups interfering with sealing, or, contamination of the sample by Teflon seal elements (if adopted). Finally the sample collection rover, or a Fetch rover, selects cups with best choice samples and loads them into a sample tray, before delivering it to the Earth Return Vehicle (ERV) in the MSR Dragon capsule as described in [1] (Fig 1). This ensures best use of the MSR payload mass allowance. A 3 meter long jointed robot arm is extended from the Dragon capsule's crew hatch, retrieves the sample tray and inserts it into the sample canister payload located on the ERV stage. The robot arm has capacity to obtain grab samples in the event of a rover failure. The sample canister has a robot arm capture casting to enable capture by crewed or robot spacecraft when it returns to Earth orbit
NASA Astrophysics Data System (ADS)
Hoskin, HLD; Furie, E.; Collins, W.; Ganey, TM; Schlatterer, DR
2017-05-01
Since Sir John Charnley began his monumental hip arthroplasty work in 1958, clinical researchers have been incrementally improving longevity and functionality of total joint systems, although implant failure occurs on occasion. The purpose of this study is to report the fracture of the humeral tray Morse taper of a reverse total shoulder system (RTSS), which to date has not been reported with metallurgic analysis for any RTSS. There was no reported antecedent fall, motor vehicle collision, or other traumatic event prior to implant fracture in this case. Analysis was performed on the retrieved failed implant by Scanning Electron Microscopy (SEM) and Electron Dispersion Spectroscopy (EDS) in an attempt to determine the failure method, as well as to offer improvements for future implants. At the time of revision surgery all explants were retained from the left shoulder of a 61-year old male who underwent a non-complicated RTSS 4 years prior. The explants, particularly the cracked humeral tray, were processed as required for SEM and EDS. Analysis was performed on the failure sites in order to determine the chemical composition of the different parts of the implant, discover the chemical composition of the filler metal used during the electron beam welding process, and to detect any foreign elements that could suggest corrosion or other evidence of failure etiology. Gross visual inspection of all explants revealed that implant failure was a result of dissociation of the taper from the humeral tray at the weld, leaving the Morse taper embedded in the humeral stem while the tray floated freely in the patient’s shoulder. SEM further confirmed the jagged edges noted grossly at the weld fracture site, both suggesting failure due to torsional forces. EDS detected elevated levels of carbon and oxygen at the fracture site on the taper only and not on the humeral tray. In order to determine the origin of the high levels of C and O, it was considered that in titanium alloys, C and O are used as stabilizers that help raise the temperature at which titanium can be cast. Since the presence of stabilizers reduces ductility and fatigue strength, all interstitial elements are removed after casting. Considering this, the presence of C and O suggests that not all of the interstitials were removed during the manufacturing process, resulting in decreased fatigue strength. Further destructive analytical testing would verify weld quality and failure mode. RTSSs are quite successful in select patients not amenable to traditional shoulder arthroplasty options. This case report highlights how an implant may function well for several years and then suddenly fail without warning. SEM and EDS analysis suggest that residual C and O in the taper lowered the metal implant’s integrity, leading to torsional cracking at the weld junction of the humeral tray and the taper. The elevated levels of C and O measured at fracture sites on both the tray and the taper suggest poor quality filler metal or failure to remove all interstitial elements after casting. In both cases, the results would be decreased fatigue strength and overall toughness, leading to mechanical failure. A manufacturer’s recall of all implants soon followed the reporting of this implant failure; subsequently, the metal materials were changed from Ti6Al4V to both titanium alloy and cobalt-chrome alloy (Co-Cr-Mo). Time will tell if the alterations were sufficient.
Moura, Renata Vasconcellos; Kojima, Alberto Noriyuki; Saraceni, Cintia Helena Coury; Bassolli, Lucas; Balducci, Ivan; Özcan, Mutlu; Mesquita, Alfredo Mikail Melo
2018-05-01
The increased use of CAD systems can generate doubt about the accuracy of digital impressions for angulated implants. The aim of this study was to evaluate the accuracy of different impression techniques, two conventional and one digital, for implants with and without angulation. We used a polyurethane cast that simulates the human maxilla according to ASTM F1839, and 6 tapered implants were installed with external hexagonal connections to simulate tooth positions 17, 15, 12, 23, 25, and 27. Implants 17 and 23 were placed with 15° of mesial angulation and distal angulation, respectively. Mini cone abutments were installed on these implants with a metal strap 1 mm in height. Conventional and digital impression procedures were performed on the maxillary master cast, and the implants were separated into 6 groups based on the technique used and measurement type: G1 - control, G2 - digital impression, G3 - conventional impression with an open tray, G4 - conventional impression with a closed tray, G5 - conventional impression with an open tray and a digital impression, and G6 - conventional impression with a closed tray and a digital impression. A statistical analysis was performed using two-way repeated measures ANOVA to compare the groups, and a Kruskal-Wallis test was conducted to analyze the accuracy of the techniques. No significant difference in the accuracy of the techniques was observed between the groups. Therefore, no differences were found among the conventional impression and the combination of conventional and digital impressions, and the angulation of the implants did not affect the accuracy of the techniques. All of the techniques exhibited trueness and had acceptable precision. The variation of the angle of the implants did not affect the accuracy of the techniques. © 2018 by the American College of Prosthodontists.
Computational study of the heat transfer of an avian egg in a tray.
Eren Ozcan, S; Andriessens, S; Berckmans, D
2010-04-01
The development of an embryo in an avian egg depends largely on its temperature. The embryo temperature is affected by its environment and the heat produced by the egg. In this paper, eggshell temperature and the heat transfer characteristics from one egg in a tray toward its environment are studied by means of computational fluid dynamics (CFD). Computational fluid dynamics simulations have the advantage of providing extensive 3-dimensional information on velocity and eggshell temperature distribution around an egg that otherwise is not possible to obtain by experiments. However, CFD results need to be validated against experimental data. The objectives were (1) to find out whether CFD can successfully simulate eggshell temperature from one egg in a tray by comparing to previously conducted experiments, (2) to visualize air flow and air temperature distribution around the egg in a detailed way, and (3) to perform sensitivity analysis on several variables affecting heat transfer. To this end, a CFD model was validated using 2 sets of temperature measurements yielding an effective model. From these simulations, it can be concluded that CFD can effectively be used to analyze heat transfer characteristics and eggshell temperature distribution around an egg. In addition, air flow and temperature distribution around the egg are visualized. It has been observed that temperature differences up to 2.6 degrees C are possible at high heat production (285 mW) and horizontal low flow rates (0.5 m/s). Sensitivity analysis indicates that average eggshell temperature is mainly affected by the inlet air velocity and temperature, flow direction, and the metabolic heat of the embryo and less by the thermal conductivity and emissivity of the egg and thermal emissivity of the tray.
Scanning electron microscope/energy dispersive x ray analysis of impact residues on LDEF tray clamps
NASA Technical Reports Server (NTRS)
Bernhard, Ronald P.; Durin, Christian; Zolensky, Michael E.
1992-01-01
To better understand the nature of particulates in low-Earth orbit (LEO), and their effects on spacecraft hardware, we are analyzing residues found in impacts on the Long Duration Exposure Facility (LDEF) tray clamps. LDEF experiment trays were held in place by 6 to 8 chromic-anodized aluminum (6061-T6) clamps that were fastened to the spacecraft frame using three stainless steel hex bolts. Each clamp exposed an area of approximately 58 sq cm (4.8 cm x 12.7 cm x .45 cm, minus the bolt coverage). Some 337 out of 774 LDEF tray clamps were archived at JSC and are available through the Meteoroid & Debris Special Investigation Group (M&D SIG). Optical scanning of clamps, starting with Bay/Row A01 and working toward H25, is being conducted at JSC to locate and document impacts as small as 40 microns. These impacts are then inspected by Scanning Electron Microscopy/Energy Dispersive X-ray Analysis (SEM/EDXA) to select those features which contain appreciable impact residue material. Based upon the composition of projectile remnants, and using criteria developed at JSC, we have made a preliminary discrimination between micrometeoroid and space debris residue-containing impact features. Presently, 13 impacts containing significant amounts of unmelted and semi-melted micrometeoritic residues were forwarded to Centre National d'Etudes Spatiales (CNES) in France. At the CNES facilities, the upgraded impacts were analyzed using a JEOL T330A SEM equipped with a NORAN Instruments, Voyager X-ray Analyzer. All residues were quantitatively characterized by composition (including oxygen and carbon) to help understand interplanetary dust as possibly being derived from comets and asteroids.
Nagel, Katrin; Bishop, Nicholas E; Schlegel, Ulf J; Püschel, Klaus; Morlock, Michael M
2017-02-01
The strength of the cement-bone interface in tibial component fixation depends on the morphology of the cement mantle. The purpose of this study was to identify thresholds of cement morphology parameters to maximize fixation strength using a minimum amount of cement. Twenty-three cadaveric tibiae were analyzed that had been implanted with tibial trays in previous studies and for which the pull-out strength of the tray had been measured. Specimens were separated into a group failing at the cement-bone interface (INTERFACE) and one failing in the bulk bone (BULK). Maximum pull-out strength corresponds to the ultimate strength of the bulk bone if the cement-bone interface is sufficiently strong. 3D models of the cement mantle in situ were reconstructed from computed tomography scans. The influences of bone mineral density and 6 cement morphology parameters (reflecting cement penetration, bone-cement interface, cement volume) on pull-out strength of the BULK group were determined using multiple regression analysis. The threshold of each parameter for classification of the specimens into either group was determined using receiver operating characteristic analysis. Cement penetration exceeding a mean of 1.1 mm or with a maximum of 5.6 mm exclusively categorized all BULK bone failure specimens. Failure strength of BULK failure specimens increased with bone mineral density (R 2 = 0.67, P < .001) but was independent of the cement morphology parameters. To maximize fixation strength, a mean cement penetration depth of at least 1.1 mm should be achieved during tibial tray cementing. Copyright © 2016 Elsevier Inc. All rights reserved.
Tray service generates more food waste in dining areas of a continuing-care retirement community.
Hackes, B L; Shanklin, C W; Kim, T; Su, A Y
1997-08-01
To determine if the type of service system affects the amount of service food waste (SFW) generated in dining areas of a continuing-care retirement community. A waste stream analysis was conducted for 7 days to determine quantity of SFW generated in three service systems: health care tray service, health care dining room with wait-staff service, and ambulatory dining room with family-style service. Weight and volume were determined. Health care tray service and wait-staff service were provided to 70 residents in a health care unit. Family-style service was provided as an optional service for 130 residents in independent-living units. An average of 229 meals were served per day. Analysis of variance and a multiple comparison method were used to compare mean weight and volume of SFW on a per meal, per day, and per week basis. During the 7-day period, 482.8 lb, or 83 gal, of SFW was disposed of Health care tray service generated more SFW by weight for all three meals than either family-style service or wait-staff service, and it generated the greatest total volume of service waste. Residents eating in the dining room with family-style service disposed of significantly less SFW by weight at lunch and dinner than those receiving the other two service styles. Changing the style of service can affect not only quantity of solid waste generated and associated disposal costs but also food and supply costs, meal acceptability, and quantity of natural resources required. The systems approach should be used to assess the feasibility of changing service system so that all costs are considered.
NASA Technical Reports Server (NTRS)
Houlihan, S. R.
1992-01-01
Data were obtained on a 3-percent model of the Space Shuttle launch vehicle in the NASA/Ames Research Center 11x11-foot and 9x7-foot Unitary Plan Wind Tunnels. This test series has been identified as IA19OA/B and was conducted from 7 Feb. 1980 to 19 Feb. 1980 (IA19OA) and from 17 March 1980 to 19 March 1980 and from 8 May 1980 to 30 May 1980 (IA19OB). The primary test objective was to obtain structural loads on the following external tank protuberances: (1) LO2 feedline; (2) GO2 pressure line; (3) LO2 antigeyser line; (4) GH2 pressure line; (5) LH2 tank cable tray; (6) LO2 tank cable tray; (7) Bipod; (8) ET/SRB cable tray; and (9) Crossbeam/Orbiter cable tray. To fulfill these objectives the following steps were taken: Eight 3-component balances were used to measure forces on various sections of 1 thru 6 above; 315 pressure orifices were distributed over all 9 above items. The LO2 feedline was instrumented with 96 pressure taps and was rotated to four positions to yield 384 pressure measurements. The LO2 antigeyser line was instrumented with 64 pressure taps and was rotated to two positions to yield 128 pressure measurements; Three Chrysler miniature flow direction probes were mounted on a traversing mechanism on the tank upper surface centerline to obtain flow field data between the forward and aft attach structures; and Schlieren photographs and ultraviolet flow photographs were taken at all test conditions. Data from each of the four test phases are presented.
NASA Technical Reports Server (NTRS)
Houlihan, S. R.
1992-01-01
Data were obtained on a 3-percent model of the Space Shuttle launch vehicle in the NASA/Ames Research Center 11x11-foot and 9x7-foot Unitary Plan Wind Tunnels. This test series has been identified as IA190A/B and was conducted from 7 Feb. 1980 to 19 Feb. 1980 (IA190A) and from 17 March 1980 to 19 March 1980 and from 8 May 1980 to 30 May 1980 (IA190B). The primary test objective was to obtain structural loads on the following external tank protuberances: (1) LO2 feedline, (2) GO2 pressure line, (3) LO2 antigeyser line, (4) GH2 pressure line, (5) LH2 tank cable tray, (6) LO2 tank cable tray, (7) Bipod, (8) ET/SRB cable tray, and (9) Crossbeam/Orbiter cable tray. To fulfill these objectives the following steps were taken: (1) Eight 3-component balances were used to measure forces on various sections of 1 thru 6 above. (2) 315 pressure orifices were distributed over all 9 above items. The LO2 feedline was instrumented with 96 pressure taps and was rotated to four positions to yield 384 pressure measurements. The LO2 antigeyser line was instrumented with 64 pressure taps and was rotated to two positions to yield 128 pressure measurements. (3) Three Chrysler miniature flow direction probes were mounted on a traversing mechanism on the tank upper surface centerline to obtain flow field data between the forward and aft attach structures. (4) Schlieren photographs and ultraviolet flow photographs were taken at all test conditions. Data from each of the four test phases are presented.
Linking Foraging Decisions to Residential Yard Bird Composition
Lerman, Susannah B.; Warren, Paige S.; Gan, Hilary; Shochat, Eyal
2012-01-01
Urban bird communities have higher densities but lower diversity compared with wildlands. However, recent studies show that residential urban yards with native plantings have higher native bird diversity compared with yards with exotic vegetation. Here we tested whether landscape designs also affect bird foraging behavior. We estimated foraging decisions by measuring the giving-up densities (GUD; amount of food resources remaining when the final forager quits foraging on an artificial food patch, i.e seed trays) in residential yards in Phoenix, AZ, USA. We assessed how two yard designs (mesic: lush, exotic vegetation; xeric: drought-tolerant and native vegetation) differed in foraging costs. Further, we developed a statistical model to calculate GUDs for every species visiting the seed tray. Birds foraging in mesic yards depleted seed trays to a lower level (i.e. had lower GUDs) compared to birds foraging in xeric yards. After accounting for bird densities, the lower GUDs in mesic yards appeared largely driven by invasive and synanthropic species. Furthermore, behavioral responses of individual species were affected by yard design. Species visiting trays in both yard designs had lower GUDs in mesic yards. Differences in resource abundance (i.e., alternative resources more abundant and of higher quality in xeric yards) contributed to our results, while predation costs associated with foraging did not. By enhancing the GUD, a common method for assessing the costs associated with foraging, our statistical model provided insights into how individual species and bird densities influenced the GUD. These differences we found in foraging behavior were indicative of differences in habitat quality, and thus our study lends additional support for native landscapes to help reverse the loss of urban bird diversity. PMID:22927974
NASA Astrophysics Data System (ADS)
Graham, G. A.; Kearsley, A. T.; Dai, Z.; Leroux, H.; Teslich, N. E.; Stroud, R.; Borg, J.; Bradley, J. P.; Horz, F. P.; Zolensky, M.
2006-12-01
The study of comets is fundamental to the understanding of early solar system processes. Much of the current knowledge of cometary compositions comes from `fly-by' missions or remote sensing studies but not, until now, from the laboratory analyses of samples. The Stardust spacecraft (NASA's 4th Discovery mission) was launched in 1999 and in January 2004 had a successful fly-by close to the nucleus of comet Wild 2. During the encounter, the collector tray assembly containing the principle particle capture technology of low- density silica aerogel was deployed. In addition, the metallic foils (1100 series Aluminum) wrapped around the collector frame also picked up material from the 6.1 km/s cometary particle collisions. Since the retrieval of the sample return capsule in January 2006, and as part of the preliminary examination, a selected number of foils have been scanned using SEM-EDX to locate cometary dust derived impact craters. Craters ranging from 100 nanometers to several hundreds of micrometers in diameter, containing both monomineralic and polymineralic projectile melts, have been identified, measured and analyzed. Focused ion beam microscopy techniques have been used to take cross-section slices of either individual craters or specific residue fragments, and thin them to electron transparency. TEM-EDX analysis of these slices shows that crystalline grains are occasionally preserved, despite the high shock pressures and temperatures that caused most of the particle to melt. Observations from the crater residues make a useful addition to studies of the composition and mineralogy of the cometary particulates preserved within the impact tracks in the silica aerogel. This work was in part performed under the auspices of the U.S. Department of Energy, National Nuclear Security Administration by the University of California, Lawrence Livermore National Laboratory under contract No. W-7405-Eng-48.
An update on Lab Rover: A hospital material transporter
NASA Technical Reports Server (NTRS)
Mattaboni, Paul
1994-01-01
The development of a hospital material transporter, 'Lab Rover', is described. Conventional material transport now utilizes people power, push carts, pneumatic tubes and tracked vehicles. Hospitals are faced with enormous pressure to reduce operating costs. Cyberotics, Inc. developed an Autonomous Intelligent Vehicle (AIV). This battery operated service robot was designed specifically for health care institutions. Applications for the AIV include distribution of clinical lab samples, pharmacy drugs, administrative records, x-ray distribution, meal tray delivery, and certain emergency room applications. The first AIV was installed at Lahey Clinic in Burlington, Mass. Lab Rover was beta tested for one year and has been 'on line' for an additional 2 years.
Real-time, T-ray imaging using a sub-terahertz gyrotron
NASA Astrophysics Data System (ADS)
Han, Seong-Tae; Torrezan, Antonio C.; Sirigiri, Jagadishwar R.; Shapiro, Michael A.; Temkin, Richard J.
2012-06-01
We demonstrated real-time, active, T-ray imaging using a 0.46 THz gyrotron capable of producing 16 W in continuous wave operation and a pyroelectric array camera with 124-by-124 pixels. An expanded Gaussian beam from the gyrotron was used to maintain the power density above the detection level of the pyroelectric array over the area of the irradiated object. Real-time imaging at a video rate of 48 Hz was achieved through the use of the built-in chopper of the camera. Potential applications include fast scanning for security purposes and for quality control of dry or frozen foods.
Autoshaping a leverpress in rats with lateral, medial, or complete septal lesions.
Poplawsky, A; Phillips, C L
1986-05-01
Rats with either control operations or lateral, medial, or complete septal lesions received 600 trials of leverpress training using an autoshaping procedure, i.e., food delivery followed a 10 s illuminated lever presentation, or occurred immediately after a leverpress. Rats with complete septal lesions acquired the leverpress faster than controls and had more food-tray entries per minute during the first 100 trials than the other groups. Rats with lateral or medial septal lesions had leverpress and food-tray entries equivalent to controls. The facilitation of autoshaping a leverpress may partially be explained by the general increase in motor reactivity to stimuli found following septal lesions.
Clinical study of the safety and effectiveness of a novel over-the-counter bleaching tray system
Ghalili, K Michael; Khawaled, Kamal; Rozen, Doran; Afsahi, Veda
2014-01-01
We investigated color change, gingival irritation, and tooth sensitivity in patients undergoing at-home vital tooth bleaching with a novel over-the-counter bleaching tray system. Tooth color shade in anterior teeth, supragingival plaque and gingivitis in Ramfjord teeth, as well as visual assessment of teeth gingival tissues and mucosa were evaluated in-office prior to treatment, after two consecutive applications of the 9% hydrogen peroxide bleaching product, after eight applications (10 minutes/day for 3 days at home), and after ten applications (50 minutes exposure over 5 days). Color stability was evaluated at 3 months after completing the treatment regimen. Over-the-counter bleaching products can be used by the patient at home without dentist supervision, but are frequently associated with gingival irritation and tooth sensitivity despite low concentrations of peroxide agents. Our investigations showed that the treatment is tolerable and safe with a low incidence of adverse effects. Any adverse effects associated with use of the whitening gel and tray are temporary, easily controlled, and often disappear within minutes of treatment. Statistical analysis revealed significant improvement in teeth whitening following treatment (mean color change of seven shades) and at three months after treatment. PMID:24591847
Simpson, D J; Kendrick, B J L; Dodd, C A F; Price, A J; Gill, H S; Murray, D W
2011-05-01
Unicompartmental knee replacement (UKR) is an appealing alternative to total knee replacement when the patient has isolated medial compartment osteoarthritis. A common observation post-operatively is radiolucency between the tibial tray wall and the bone. In addition, some patients complain of persistent pain over the proximal tibia antero-medially; this may be related to elevated bone strains in the tibia. Currently, there is no intentionally made mechanical bond between the vertical wall of an Oxford UKR and the adjacent bone; whether one exists or not will influence the load transmission in the proximal tibia and may affect the elevated tibia strain. The aim of this study was to investigate how introducing a mechanical tie between the tibial tray wall and the adjacent bone might alter the load carried into the tibia for both cemented and cementless UKRs. Strain energy density in the region of bone adjacent to the tray wall was considerably increased when a mechanical tie was introduced; this has the potential of reducing the likelihood of a radiolucency occurring in that region. Moreover, a mechanical tie had the effect of reducing proximal tibia strain, which may decrease the incidence of pain following implantation with a UKR.
Ada, Louise; Foongchomcheay, Anchalee; Langhammer, Birgitta; Preston, Elisabeth; Stanton, Rosalyn; Robinson, John; Paul, Serene; Canning, Colleen
2017-02-01
Shoulder subluxation is a common secondary impairment of the upper limb following stroke. A range of supportive devices are used in rehabilitation to prevent shoulder subluxation, including hemi-slings and firm supports, such as arm troughs, however, there is little evidence regarding their efficacy. To determine whether a modified lap-tray during sitting and a triangular sling during standing is more effective than a hemi-sling in preventing shoulder subluxation, pain, contracture and upper limb activity limitation after stroke. A prospective, randomized trial with concealed allocation, assessor blinding and intention-to-treat analysis. Three inpatient rehabilitation units in Australia and Norway. Forty-six acute stroke survivors within 3 weeks of stroke who were at risk of subluxation. The experimental group used a modified lap-tray while sitting and a triangular sling while standing to support the affected arm for four weeks. The control group used a hemi-sling while sitting and standing. The primary outcome was amount of shoulder subluxation on X-ray. Secondary outcomes were upper limb activity, pain and contracture. There was no significant difference between groups in terms of shoulder subluxation (MD -3 mm, 95% CI -8 to 3). There was a trend for the experimental group to develop less pain at rest (MD -0.7 out of 10, 95% CI -2.2 to 0.8) and during shoulder external rotation (MD -1.7 out of 10, 95% CI -3.7 to 0.3) and a trend towards having less contracture of shoulder external rotation (MD -10 deg, 95% CI -22 to 2). There was no significant difference between groups in terms of other contractures and activity of the upper limb. A lap-tray during sitting combined with a triangular sling during standing is no more effective than a hemi-sling in preventing subluxation, pain, contracture and activity limitation in acute stroke survivors at risk of shoulder subluxation. The use of a lap-tray during sitting and triangular sling during standing is not indicated as an alternative to the hemi-sling to prevent shoulder subluxation in patients after stroke, so alternative strategies with proven efficacy, such as electrical stimulation, should be considered.
Deployable video conference table
NASA Technical Reports Server (NTRS)
Cohen, Marc M. (Inventor); Lissol, Peter (Inventor)
1993-01-01
A deployable table is presented. The table is stowed in and deployed from a storage compartment based upon a non-self rigidizing, 4-hinge, arch support structure that folds upon itself to stow and that expands to deploy. The work surfaces bypass each other above and below to allow the deployment mechanism to operate. This assembly includes the following: first and second primary pivot hinges placed at the opposite ends of the storage compartment; first and second lateral frame members with proximal ends connected to the first and second pivot hinges; a medial frame member offset from and pivotally connected to distal ends of the first and second members through third and fourth medial pivot hinges; and left-side, right-side, and middle trays connected respectively to the first, second, and third frame members and being foldable into and out of the storage compartment by articulation of the first, second, third, and fourth joints. At least one of the third and fourth joints are locked to set the first, second, and third frame members in a desired angular orientation with respect to each other.
Seed-to-seed growth of Arabidopsis thaliana on the International Space Station
NASA Technical Reports Server (NTRS)
Link, B. M.; Durst, S. J.; Zhou, W.; Stankovic, B.
2003-01-01
The assembly of the International Space Station (ISS) as a permanent experimental outpost has provided the opportunity for quality plant research in space. To take advantage of this orbital laboratory, engineers and scientists at the Wisconsin Center for Space Automation and Robotics (WCSAR), University of Wisconsin-Madison, developed a plant growth facility capable of supporting plant growth in the microgravity environment. Utilizing this Advanced Astroculture (ADVASC) plant growth facility, an experiment was conducted with the objective to grow Arabidopsis thaliana plants from seed-to-seed on the ISS. Dry Arabidopsis seeds were anchored in the root tray of the ADVASC growth chamber. These seeds were successfully germinated from May 10 until the end of June 2001. Arabidopsis plants grew and completed a full life cycle in microgravity. This experiment demonstrated that ADVASC is capable of providing environment conditions suitable for plant growth and development in microgravity. The normal progression through the life cycle, as well as the postflight morphometric analyses, demonstrate that Arabidopsis thaliana does not require the presence of gravity for growth and development. c2003 COSPAR. Published by Elsevier Ltd. All rights reserved.
Space Transportation System (STS)-117 External Tank (ET)-124 Hail Damage Repair Assessment
NASA Technical Reports Server (NTRS)
Wilson, Timmy R.; Gentz, Steven J.; Barth, Timothy S.; Minute, Stephen A.; Flowers, Cody P.; Hamilton, David A.; Null, Cynthia H.; Schafer, Charles F.
2009-01-01
Severe thunderstorms with associated hail and high winds struck the STS-117 stack on February 26, 2007. Peak winds were recorded at 62 knots with hail sizes ranging from 0.3 inch to 0.8 inch in diameter. As a result of the storm, the North Carolina Foam Institute (NCFI) type 24-124 Thermal Protection System (TPS) foam on the liquid oxygen (LO2) ogive acreage incurred significant impact damage. The NCFI on the ET intertank and the liquid hydrogen (LH2) acreage sustained hail damage. The Polymer Development Laboratory (PDL)-1034 foam of the LO2 ice frost ramps (IFRs) and the Super-Lightweight Ablator (SLA) of the LO2 cable tray also suffered minor damage. NASA Engineering and Safety Center (NESC) was asked to assess the technical feasibility of repairing the ET TPS, the reasonableness of conducting those repairs with the vehicle in a vertical, integrated configuration at the Kennedy Space Center (KSC) Vehicle Assemble Building (VAB), and to address attendant human factors considerations including worker fatigue and the potential for error. The outcome of the assessment is recorded in this document.
Rotor for processing liquids using movable capillary tubes
Johnson, Wayne F.; Burtis, Carl A.; Walker, William A.
1989-01-01
A rotor assembly for processing liquids, especially whole blood samples, is disclosed. The assembly includes apparatus for separating non-liquid components of whole blood samples from liquid components, apparatus for diluting the separated liquid component with a diluent and apparatus for transferring the diluted sample to an external apparatus for analysis. The rotor assembly employs several movable capillary tubes to handle the sample and diluents. A method for using the rotor assembly to process liquids is also described.
Rotor for processing liquids using movable capillary tubes
Johnson, Wayne F [Loudon, TN; Burtis, Carl A [Oak Ridge, TN; Walker, William A [Knoxville, TN
1989-05-30
A rotor assembly for processing liquids, especially whole blood samples, is disclosed. The assembly includes apparatus for separating non-liquid components of whole blood samples from liquid components, apparatus for diluting the separated liquid component with a diluent and apparatus for transferring the diluted sample to an external apparatus for analysis. The rotor assembly employs several movable capillary tubes to handle the sample and diluents. A method for using the rotor assembly to process liquids is also described.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Tianfu; Wang, Zhen; Li, Guoping
2015-10-15
A bottom-up approach combining soft template self-assembly with sol–gel process, was adopted to prepare the assembled Al/Fe{sub 2}O{sub 3} nanoenergetic materials, assembly-Al/Fe{sub 2}O{sub 3} sample. The other two unassembled Al/Fe{sub 2}O{sub 3}a nanoenergetic materials, sol–gel–Al/Fe{sub 2}O{sub 3} sample and mixing-Al/Fe{sub 2}O{sub 3} sample, were prepared by sol–gel method and physical mixing method respectively. The assembly process within the preparation of the assembly-Al/Fe{sub 2}O{sub 3} sample was analyzed through the changes in the average hydrodynamic diameters of the particles and the micelles in solution. SEM, EDS and TEM tests were performed to demonstrate a significant improvement regarding to dispersity and arrangementsmore » of the Al and Fe{sub 2}O{sub 3} particles in the assembled samples, compared to that of the unassembled Al/Fe{sub 2}O{sub 3} samples. DSC test was employed to characterize the reactivity of the samples. The heat release of the assembled Al/Fe{sub 2}O{sub 3} sample was 2088 J/g, about 400 and 990 J/g more than that of the sol–gel–Al/Fe{sub 2}O{sub 3} sample and mixing-Al/Fe{sub 2}O{sub 3} sample, respectively. - Graphical abstract: Modified aluminum (Al) nanoparticles with hydrophobic surface assembled into the Brij S10 micelle in Fe(III) sol, then the well dispersed system was transformed into Al/Fe{sub 2}O{sub 3} nanoenergetic materials with high reactivity. - Highlights: • An approach combining soft template self-assembly with sol–gel process was adopted. • The aggregation of Al nanoparticles in the final product was reduced significantly. • The reactivity of Al/Fe{sub 2}O{sub 3} nanoenergetic materials was improved to a large extent.« less
Rotor for processing liquids using movable capillary tubes
Johnson, W.F.; Burtis, C.A.; Walker, W.A.
1987-07-17
A rotor assembly for processing liquids, especially whole blood samples, is disclosed. The assembly includes apparatus for separating non-liquid components of whole blood samples from liquid components, apparatus for diluting the separated liquid component with a diluent and apparatus for transferring the diluted sample to an external apparatus for analysis. The rotor assembly employs several movable capillary tubes to handle the sample and diluents. A method for using the rotor assembly to process liquids is also described. 5 figs.
NASA Astrophysics Data System (ADS)
Pries, V. V.; Proskuriakov, N. E.
2018-04-01
To control the assembly quality of multi-element mass-produced products on automatic rotor lines, control methods with operational feedback are required. However, due to possible failures in the operation of the devices and systems of automatic rotor line, there is always a real probability of getting defective (incomplete) products into the output process stream. Therefore, a continuous sampling control of the products completeness, based on the use of statistical methods, remains an important element in managing the quality of assembly of multi-element mass products on automatic rotor lines. The feature of continuous sampling control of the multi-element products completeness in the assembly process is its breaking sort, which excludes the possibility of returning component parts after sampling control to the process stream and leads to a decrease in the actual productivity of the assembly equipment. Therefore, the use of statistical procedures for continuous sampling control of the multi-element products completeness when assembled on automatic rotor lines requires the use of such sampling plans that ensure a minimum size of control samples. Comparison of the values of the limit of the average output defect level for the continuous sampling plan (CSP) and for the automated continuous sampling plan (ACSP) shows the possibility of providing lower limit values for the average output defects level using the ACSP-1. Also, the average sample size when using the ACSP-1 plan is less than when using the CSP-1 plan. Thus, the application of statistical methods in the assembly quality management of multi-element products on automatic rotor lines, involving the use of proposed plans and methods for continuous selective control, will allow to automating sampling control procedures and the required level of quality of assembled products while minimizing sample size.
Force Limited Vibration Test of HESSI Imager
NASA Technical Reports Server (NTRS)
Amato, Deborah; Pankow, David; Thomsen, Knud
2000-01-01
The High Energy Solar Spectroscopic Imager (HESSI) is a solar x-ray and gamma-ray observatory scheduled for launch in November 2000. Vibration testing of the HESSI imager flight unit was performed in August 1999. The HESSI imager consists of a composite metering tube, two aluminum trays mounted to the tube on titanium flexure mounts, and nine modulation grids mounted on each tray. The vibration tests were acceleration controlled and force limited, in order to prevent overtesting. The force limited strategy reduced the shaker force and notched the acceleration at resonances. The test set-up, test levels, and results are presented. The development of the force limits is also discussed. The imager successfully survived the vibration testing.
1. GENERAL VIEW OF SLC3W SHOWING SOUTH FACE AND EAST ...
1. GENERAL VIEW OF SLC-3W SHOWING SOUTH FACE AND EAST SIDE OF A-FRAME MOBILE SERVICE TOWER (MST). MST IN SERVICE POSITION OVER LAUNCHER AND FLAME BUCKET. CABLE TRAYS BETWEEN LAUNCH OPERATIONS BUILDING (BLDG. 763) AND SLC-3W IN FOREGROUND. LIQUID OXYGEN APRON VISIBLE IMMEDIATELY EAST (RIGHT) OF MST; FUEL APRON VISIBLE IMMEDIATELY WEST (LEFT) OF MST. A PORTION OF THE FLAME BUCKET VISIBLE BELOW THE SOUTH FACE OF THE MST. CAMERA TOWERS VISIBLE EAST OF MST BETWEEN ROAD AND CABLE TRAY, AND SOUTH OF MST NEAR LEFT MARGIN OF PHOTOGRAPH. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
NASA Technical Reports Server (NTRS)
Sandford, S. A.; Aleon, J.; Alexander, C. M. O'D.; Araki, T.; Bajt, S.; Baratta, G. A.; Borg, J.; Bradley J. P.; Brownlee, D. E.; Brucato, J. R.;
2007-01-01
STARDUST is the first mission designed to bring samples back to Earth from a known comet. The captured samples were successfully returned to Earth on 15 Jan 2006, after which they were subjected to a preliminary examination by a number of teams of scientists from around the world. This abstract describes the efforts of the Organics Preliminary Examination Team (PET). More detailed discussions of specific analyses of the samples can be found in other papers presented at this meeting by individual members of the Organics PET (see the author list above for team members). The studied Wild 2 gas and dust samples were collected by impact onto aerogel tiles and Al foils when the spacecraft flew through the coma of 81P/Wild 2 on 2 Jan 2004 at a relative velocity of approx.6.1 kilometers per second. After recovery of the Sample Return Capsule (SRC) on 15 Jan 2006, the aerogel collector trays were removed in a clean room at JSC. After documentation of the collection, selected aerogel tiles and aluminum foils were removed and aerogel and cometary samples extracted for study.
Rodriguez Tadeo, Alejandra; Patiño Villena, Begoña; Periago Castón, María Jesús; Ros Berruezo, Gaspar; González Martínez-Lacuesta, Eduardo
2014-05-01
School canteens have rules of management and supervision of menus, however has not been assessed if they are totally consumed. To assess the acceptance of food by weigh food leftovers and validation of a methodology for visual estimation in school canteens of Murcia. Participated pupils in the second and third cycle of primary education, between 8 and 12 years. The estimate of leftovers was performed by 765 food trays. Visual estimation of 300 trays was based on a categorical scale as follow: 1 (0-25%), 2 (26-50%), 3 (51- 75%), 4 (76-100%) by two dietitians and reliability was assessed with respect to the weighed food. The reliability between both methods was assessed in two samples stratified by presence or absence of school kitchen. The first dishes with leftovers were pasta, rice and vegetable purees and was higher in those schools without kitchen (p < 0.05). Also, the second dishes poultry and fish salads and vegetables garnish. Fruit and the total sum of leftovers was higher in schools without dining menus (p < 0.05). The agreement between evaluators was high in meat dishes and salads, and substantial in vegetables, pre-cooked, omelet, pasta, fish and rice. The leftlovers are high and there are differences in the acceptance of certain foods according to the type of menu offered. The visual scale is a reliable to measure acceptance indirectly, but training to catering staff is needed. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Space environment durability of beta cloth in LDEF thermal blankets
NASA Technical Reports Server (NTRS)
Linton, Roger C.; Whitaker, Ann F.; Finckenor, Miria M.
1993-01-01
Beta cloth performance for use on long-term space vehicles such as Space Station Freedom (S.S. Freedom) requires resistance to the degrading effects of the space environment. The major issues are retention of thermal insulating properties through maintaining optical properties, preserving mechanical integrity, and generating minimal particulates for contamination-sensitive spacecraft surfaces and payloads. The longest in-flight test of beta cloth's durability was on the Long Duration Exposure Facility (LDEF), where it was exposed to the space environment for 68 months. The LDEF contained 57 experiments which further defined the space environment and its effects on spacecraft materials. It was deployed into low-Earth orbit (LEO) in Apr. 1984 and retrieved Jan. 1990 by the space shuttle. Among the 10,000 plus material constituents and samples onboard were thermal control blankets of multilayer insulation with a beta cloth outer cover and Velcro attachments. These blankets were exposed to hard vacuum, thermal cycling, charged particles, meteoroid/debris impacts, ultraviolet (UV) radiation, and atomic oxygen (AO). Of these space environmental exposure elements, AO appears to have had the greatest effect on the beta cloth. The beta cloth analyzed in this report came from the MSFC Experiment S1005 (Transverse Flat-Plate Heat Pipe) tray oriented approximately 22 deg from the leading edge vector of the LDEF satellite. The location of the tray on LDEF and the placement of the beta cloth thermal blankets are shown. The specific space environment exposure conditions for this material are listed.
A Combined Fabrication and Instrumentation Platform for Sample Preparation.
Guckenberger, David J; Thomas, Peter C; Rothbauer, Jacob; LaVanway, Alex J; Anderson, Meghan; Gilson, Dan; Fawcett, Kevin; Berto, Tristan; Barrett, Kevin; Beebe, David J; Berry, Scott M
2014-06-01
While potentially powerful, access to molecular diagnostics is substantially limited in the developing world. Here we present an approach to reduced cost molecular diagnostic instrumentation that has the potential to empower developing world communities by reducing costs through streamlining the sample preparation process. In addition, this instrument is capable of producing its own consumable devices on demand, reducing reliance on assay suppliers. Furthermore, this instrument is designed with an "open" architecture, allowing users to visually observe the assay process and make modifications as necessary (as opposed to traditional "black box" systems). This open environment enables integration of microfluidic fabrication and viral RNA purification onto an easy-to-use modular system via the use of interchangeable trays. Here we employ this system to develop a protocol to fabricate microfluidic devices and then use these devices to isolate viral RNA from serum for the measurement of human immunodeficiency virus (HIV) viral load. Results obtained from this method show significantly reduced error compared with similar nonautomated sample preparation processes. © 2014 Society for Laboratory Automation and Screening.
Widman, Travis J; Oostman, Holly; Storrs, Frances J
2008-01-01
Medical adhesive bandages are extensively used in both inpatient and outpatient medicine. However, few reports describing proven allergic contact dermatitis (ACD) from medical adhesive bandages exist in the literature. These reports do not adequately correspond to the frequency that patients report having an "allergy" to medical adhesive bandages. To determine if there is a chemical present in medical adhesive bandages that causes ACD in people who identify themselves as having an "allergy" to medical adhesive bandages. Twenty-six patients were enrolled and underwent patch testing with our standard trays (104 chemicals) and a customized adhesive tray (54 chemicals and 10 tapes and bandages in their whole form). We were able to identify an allergen in four patients that was related to their presumed adhesive allergy (Mastisol, neomycin/bacitracin [two different patients], and cortisone-10 cream, respectively). However, there were no positive allergic reactions to the tapes or bandages or any relevant allergic reactions to our customized adhesive tray. Eight (73%) of the 11 patients who had the bandage or tape left on for 7 days had an irritant reaction. We feel that the perceived reactions are not secondary to ACD but instead are due to an irritant contact dermatitis.
NASA Technical Reports Server (NTRS)
Witte, W. G., Jr.
1985-01-01
One of the experiments aboard the NASA Long Duration Exposure Facility (LDEF) consists of a tray of approximately one hundred tensile specimens of several candidate space structure composite materials. During the LDEF flight the materials will be subjected to the space environment and to possible contamination during launch and recovery. Tensile tests of representative samples were made before the LDEF flight to obtain baseline data. Similar tests will be made on control specimens stored on earth for the length of the LDEF flight and on recovered flight specimens. This manual codifies the details of testing, data acquisition, and handling used in obtaining the baseline data so that the same procedures and equipment will be used on the subsequent tests.
NASA Astrophysics Data System (ADS)
Stark, N.; Hay, A. E.; Cheel, R.; Lake, C. B.
2013-12-01
The impact of particle shape on the friction angle, and the resulting critical shear stress on sediment dynamics, is still poorly understood. In areas characterized by sediments of specific shape, particularly non-rounded particles, this can lead to large departures from the expected sediment dynamics. The steep slope (1:10) of the mixed sand-gravel beach at Advocate Harbour was found stable in large-scale morphology over decades, despite a high tidal range of ten meters or more, and strong shorebreak action during storms. The Advocate sand (d < 2 mm) was found to have an elliptic, plate-like shape. Exceptionally high friction angles of the material were determined using direct shear, ranging from φ ≈ 41-46°, while the round to angular gravel was characterized by φ = 33°. The addition of 25% of the elliptic sand to the gravel led to an immediate increase of the friction angle to φ = 38°. Furthermore, re-organization of the particles occurred during shearing, being characterized by a short phase of settling and compaction, followed by a pronounced strong dilatory behavior and an accompanying strong increase of shear stress. Long-term shearing (24 h) using a ring shear apparatus led to destruction of the particles without re-compaction. Finally, submerged particle mobilization was simulated using a tilted tray in a tank. Despite a smooth tray surface, particle motion was not initiated until reaching tray tilt angles of 31° and more, being 7° steeper than the latest gravel motion initiation. In conclusion, geotechnical laboratory experiments quantified the important impact of the elliptic, plate-like shape of Advocate Beach sand on the friction angles of both pure sand and sand-gravel mixtures. The resulting effect on initiation of particle motion was confirmed in tilting tray experiments. This makes it a vivid example of how particle shape can contribute to the stabilization of the beachface.
Research on Spent Fuel Storage and Transportation in CRIEPI (Part 2 Concrete Cask Storage)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koji Shirai; Jyunichi Tani; Taku Arai
2008-10-01
Concrete cask storage has been implemented in the world. At a later stage of storage period, the containment of the canister may deteriorate due to stress corrosion cracking phenomena in a salty air environment. High resistant stainless steels against SCC have been tested as compared with normal stainless steel. Taking account of the limited time-length of environment with certain level of humidity and temperature range, the high resistant stainless steels will survive from SCC damage. In addition, the adhesion of salt from salty environment on the canister surface will be further limited with respect to the canister temperature and anglemore » of the canister surface against the salty air flow in the concrete cask. Optional countermeasure against SCC with respect to salty air environment has been studied. Devices consisting of various water trays to trap salty particles from the salty air were designed to be attached at the air inlet for natural cooling of the cask storage building. Efficiency for trapping salty particles was evaluated. Inspection of canister surface was carried out using an optical camera inserted from the air outlet through the annulus of a concrete cask that has stored real spent fuel for more than 15 years. The camera image revealed no gross degradation on the surface of the canister. Seismic response of a full-scale concrete cask with simulated spent fuel assemblies has been demonstrated. The cask did not tip over, but laterally moved by the earthquake motion. Stress generated on the surface of the spent fuel assemblies during the earthquake motion were within the elastic region.« less
Sampling scheme for pyrethroids on multiple surfaces on commercial aircrafts.
Mohan, Krishnan R; Weisel, Clifford P
2010-06-01
A wipe sampler for the collection of permethrin from soft and hard surfaces has been developed for use in aircraft. "Disinsection" or application of pesticides, predominantly pyrethrods, inside commercial aircraft is routinely required by some countries and is done on an as-needed basis by airlines resulting in potential pesticide dermal and inhalation exposures to the crew and passengers. A wipe method using filter paper and water was evaluated for both soft and hard aircraft surfaces. Permethrin was analyzed by GC/MS after its ultrasonication extraction from the sampling medium into hexane and volume reduction. Recoveries, based on spraying known levels of permethrin, were 80-100% from table trays, seat handles and rugs; and 40-50% from seat cushions. The wipe sampler is easy to use, requires minimum training, is compatible with the regulations on what can be brought through security for use on commercial aircraft, and readily adaptable for use in residential and other settings.
NASA Technical Reports Server (NTRS)
Borg, J.; Horz, F.; Bridges, J. C.; Burchell, M. J.; Djouadi, Z.; Floss, C.; Graham, G. A.; Green, S. F.; Heck, P. R.; Hoppe, P.;
2007-01-01
Aluminium foils were used on Stardust to stabilize the aerogel specimens in the modular collector tray. Part of these foils were fully exposed to the flux of cometary grains emanating from Wild 2. Because the exposed part of these foils had to be harvested before extraction of the aerogel, numerous foil strips some 1.7 mm wide and 13 or 33 mm long were generated during Stardusts's Preliminary Examination (PE). These strips are readily accommodated in their entirety in the sample chambers of modern SEMs, thus providing the opportunity to characterize in situ the size distribution and residue composition - employing EDS methods - of statistically more significant numbers of cometary dust particles compared to aerogel, the latter mandating extensive sample preparation. We describe here the analysis of nearly 300 impact craters and their implications for Wild 2 dust.
Somatic Coliphage Profiles of Produce and Environmental Samples from Farms in Northern México.
Bartz, Faith E; Hodge, Domonique Watson; Heredia, Norma; de Aceituno, Anna Fabiszewski; Solís, Luisa; Jaykus, Lee-Ann; Garcia, Santos; Leon, Juan S
2016-09-01
Somatic coliphages were quantified in 459 produce and environmental samples from 11 farms in Northern Mexico to compare amounts of somatic coliphages among different types of fresh produce and environmental samples across the production steps on farms. Rinsates from cantaloupe melons, jalapeño peppers, tomatoes, and the hands of workers, soil, and water were collected during 2011-2012 at four successive steps on each farm, from the field before harvest through the packing facility, and assayed by FastPhage MPN Quanti-tray method. Cantaloupe farm samples contained more coliphages than jalapeño or tomato (p range <0.01-0.03). Across production steps, jalapeños had higher coliphage percentages before harvest than during packing (p = 0.03), while tomatoes had higher coliphage concentrations at packing than all preceding production steps (p range <0.01-0.02). These findings support the use of targeted produce-specific interventions at multiple points in the process of growing and packing produce to reduce the risk of enteric virus contamination and improve food safety during fruit and vegetable production.
Looking for Microbes in a Spacecraft Assembly Clean Room
2013-11-06
A microbiologist collects a swab sample from the floor of a spacecraft assembly clean room at NASA Jet Propulsion Laboratory where samples such as this are taken frequently during the assembly of a spacecraft and analyzed.
1970-01-01
Shown here is the Skylab food heating and serving tray in its stowed position. The Marshall Space Flight Center had program management responsibility for the development of Skylab hardware and experiments.
Modification of Fixture Mount to be Used as an Impression Coping in Closely Placed Implants
Jain, Anoop; K, Cauvery; Kumar, Pawan; Havale, Raghavendra
2014-01-01
An implant-level impression is often desired for designing and fabricating an implant-supported fixed restoration. This clinical report describes the use of modified press-fit metal implant fixture mount as an impression coping for making an impression of closely placed implants. The fixture mount is easier to manipulate, time saving and more comfortable for both the clinician and patient because the implant fixture mount is connected to the implant by pressing on instead of screwing. As compared to plastic press fit impression coping, metal fixture mount will not distort when modification of fixture mount are required in convergently or closely placed implants. It has the advantage of both the open-tray and closed-tray implant impression techniques. PMID:24959520
Metcalf, H.E.
1957-10-01
A reactor of the type which preferably uses plutonium as the fuel and a liquid moderator, preferably ordinary water, and which produces steam within the reactor core due to the heat of the chain reaction is described. In the reactor shown the fuel elements are essentially in the form of trays and are ventically stacked in spaced relationship. The water moderator is continuously supplied to the trays to maintain a constant level on the upper surfaces of the fuel element as it is continually evaporated by the heat. The steam passes out through the spaces between the fuel elements and is drawn off at the top of the core. The fuel elements are clad in aluminum to prevent deterioration thereof with consequent contamimation of the water.
1994-02-16
These Vapor Diffusion Apparatus (VDA) trays were first flown in the Thermal Enclosure System (TES) during the USMP-2 (STS-62) mission. Each tray can hold 20 protein crystal growth chambers. Each chamber contains a double-barrel syringe; one barrel holds protein crystal solution and the other holds precipitant agent solution. During the microgravity mission, a torque device is used to simultaneously retract the plugs in all 20 syringes. The two solutions in each chamber are then mixed. After mixing, droplets of the combined solutions are moved onto the syringe tips so vapor diffusion can begin. During the length of the mission, protein crystals are grown in the droplets. Shortly before the Shuttle's return to Earth, the experiment is deactivated by retracting the droplets containing protein crystals, back into the syringes.
Meyerowitz, C; Watson, G E
1998-09-01
This study compared the anticaries effectiveness of an intraoral fluoride-releasing system, or IFRS, with a standard regimen of daily application of a 1.1 percent neutral sodium fluoride gel in custom trays. Caries protection in subjects in the IFRS group was comparable to that in subjects in the 1.1 percent neutral sodium fluoride group. The subjects all had head or neck cancer and had received radiation therapy, but no more recently than three months before taking part in the study. Overall, IFRS devices were well-tolerated and patient satisfaction was high. The IFRS appears to offer several advantages over the daily application of fluoride gels in custom trays.
Modification of Fixture Mount to be Used as an Impression Coping in Closely Placed Implants.
Mahoorkar, Sudhindra; Jain, Anoop; K, Cauvery; Kumar, Pawan; Havale, Raghavendra
2014-04-01
An implant-level impression is often desired for designing and fabricating an implant-supported fixed restoration. This clinical report describes the use of modified press-fit metal implant fixture mount as an impression coping for making an impression of closely placed implants. The fixture mount is easier to manipulate, time saving and more comfortable for both the clinician and patient because the implant fixture mount is connected to the implant by pressing on instead of screwing. As compared to plastic press fit impression coping, metal fixture mount will not distort when modification of fixture mount are required in convergently or closely placed implants. It has the advantage of both the open-tray and closed-tray implant impression techniques.
Key facilitators and best practices of hotel-style room service in hospitals.
Sheehan-Smith, Lisa
2006-04-01
This qualitative study sought to identify the features, advantages, and disadvantages of hotel-style room service; the barriers to, and facilitators for, implementing the process; and "best practices." The study took place in four heterogeneous hospitals. Participants included hospital administrators, managers, and room-service employees. Data-collection methods included semi-structured interviews, observations, and document analysis. Common features of hotel-style room service were meal delivery within 30 to 45 minutes, a restaurant-style menu, procedures to feed ineligible patients, tray assembly on demand, scripting, and waitstaff uniforms for room-service employees. The major barrier to implementing room service was obtaining nursing support. The key facilitators were the hospital's service-oriented culture, using a multidisciplinary planning team, engaging nursing departments early in the planning stages, and intense customer-service training of room-service employees. The overwhelming advantage was patients' control over their food choices. The main disadvantage was cost. Initial best practices in hotel-style room service include: (a) taking a multidisciplinary team approach for developing and implementing the process, (b) customer-service training, (c) using a customer-driven menu, (d) wearing waitstaff uniforms, and (e) using carts with airpots for dispensing hot beverages.
Airborne rotary air separator study
NASA Technical Reports Server (NTRS)
Acharya, A.; Gottzmann, C. F.; Nowobilski, J. J.
1990-01-01
Several air breathing propulsion concepts for future earth-to-orbit transport vehicles utilize air collection and enrichment, and subsequent storage of liquid oxygen for later use in the vehicle emission. Work performed during the 1960's established the feasibility of substantially reducing weight and volume of a distillation type air separator system by operating the distillation elements in high 'g' fields obtained by rotating the separator assembly. This contract studied the capability test and hydraulic behavior of a novel structured or ordered distillation packing in a rotating device using air and water. Pressure drop and flood points were measured for different air and water flow rates in gravitational fields of up to 700 g. Behavior of the packing follows the correlations previously derived from tests at normal gravity. The novel ordered packing can take the place of trays in a rotating air separation column with the promise of substantial reduction in pressure drop, volume, and system weight. The results obtained in the program are used to predict design and performance of rotary separators for air collection and enrichment systems of interest for past and present concepts of air breathing propulsion (single or two-stage to orbit) systems.
Orbital atomic oxygen effects on materials: An overview of MSFC experiments on the STS-46 EOIM-3
NASA Astrophysics Data System (ADS)
Linton, Roger C.; Vaughn, Jason A.; Finckenor, Miria M.; Kamenetzky, Rachel R.; Dehaye, Robert F.; Whitaker, Ann F.
1995-02-01
The third Evaluation of Oxygen Interaction with Materials experiment was flown on Space Shuttle Mission STS-46 (July 31 - August 8, 1992), representing a joint effort of several NASA centers, universities, and contractors. This array of active instrumentation and material exposure sub-assemblies was integrated as a Shuttle cargo bay pallet experiment for investigating the effects of orbital atomic oxygen on candidate space materials. Marshall Space Flight Center contributed several passive exposure trays of material specimens, uniform stress and static stress material exposure fixtures, the Atomic Oxygen Resistance Monitor (AORM), and specimens of thermal coatings for the EOIM-3 variable exposure mechanisms. As a result of 42 hours of spacecraft velocity vector-oriented exposure during the later phases of the STS-46 mission in LEO, EOIM-3 materials were exposed to an atomic oxygen fluence of 2.2 x 10(exp 20) atoms/sq cm. In this paper, an overview is presented of the technical approaches and results from analyses of the MSFC flight specimens, fixtures, and the AORM. More detailed results from earlier EOIM missions, the LDEF, and from laboratory testing are included in associated papers of this conference session.
Orbital atomic oxygen effects on materials: An overview of MSFC experiments on the STS-46 EOIM-3
NASA Technical Reports Server (NTRS)
Linton, Roger C.; Vaughn, Jason A.; Finckenor, Miria M.; Kamenetzky, Rachel R.; Dehaye, Robert F.; Whitaker, Ann F.
1995-01-01
The third Evaluation of Oxygen Interaction with Materials experiment was flown on Space Shuttle Mission STS-46 (July 31 - August 8, 1992), representing a joint effort of several NASA centers, universities, and contractors. This array of active instrumentation and material exposure sub-assemblies was integrated as a Shuttle cargo bay pallet experiment for investigating the effects of orbital atomic oxygen on candidate space materials. Marshall Space Flight Center contributed several passive exposure trays of material specimens, uniform stress and static stress material exposure fixtures, the Atomic Oxygen Resistance Monitor (AORM), and specimens of thermal coatings for the EOIM-3 variable exposure mechanisms. As a result of 42 hours of spacecraft velocity vector-oriented exposure during the later phases of the STS-46 mission in LEO, EOIM-3 materials were exposed to an atomic oxygen fluence of 2.2 x 10(exp 20) atoms/sq cm. In this paper, an overview is presented of the technical approaches and results from analyses of the MSFC flight specimens, fixtures, and the AORM. More detailed results from earlier EOIM missions, the LDEF, and from laboratory testing are included in associated papers of this conference session.
Kang, S-H; Lee, J-W; Lim, S-H; Kim, Y-H; Kim, M-K
2014-10-01
The goal of the present study was to compare the accuracy of dental image replacement on a cone beam computed tomography (CBCT) image using digital image data from three-dimensional (3D) optical scanning of a dental cast, occlusal bite, and bite tray impression. A Bracket Typodont dental model was used. CBCT of the dental model was performed and the data were converted to stereolithography (STL) format. Three experimental materials, a dental cast, occlusal bite, and bite tray impression, were optically scanned in 3D. STL files converted from the CBCT of the Typodont model and the 3D optical-scanned STL files of the study materials were image-registered. The error range of each methodology was measured and compared with a 3D optical scan of the Typodont. For the three materials, the smallest error observed was 0.099±0.114mm (mean error±standard deviation) for registering the 3D optical scan image of the dental cast onto the CBCT dental image. Although producing a dental cast can be laborious, the study results indicate that it is the preferred method. In addition, an occlusal bite is recommended when bite impression materials are used. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Zhao, Xinshan; Huang, Xianjun; Yao, Juntao; Zhou, Yue; Jia, Rong
2015-06-01
The growth of Irpex lacteus F17 and manganese peroxidase (MnP) production in a selfdesigned tray bioreactor, operating in solid-state conditions at a laboratory scale, were studied. The bioreactor was divided into three layers by three perforated trays. Agroindustrial residues were used both as the carrier of bound mycelia and as a nutrient medium for the growth of I. lacteus F17. The maximum biomass production in the bioreactor was detected at 60 h of fermentation, which was consistent with the CO2 releasing rate by the fungus. During the stationary phase of fungal growth, the maximum MnP activity was observed, reaching 950 U/l at 84 h. Scanning electron microscopy images clearly showed the growth situation of mycelia on the support matrix. Furthermore, the MnP produced by I. lacteus F17 in the bioreactor was isolated and purified, and the internal peptide sequences were also identified with mass spectrometry. The optimal activity of the enzyme was detected at pH 7 and 25 °C, with a long half-life time of 9 days. In addition, the MnP exhibited significant stability within a broad pH range of 4-7 and at temperature up to 55 °C. Besides this, the MnP showed the ability to decolorize the polymeric model dye Poly R-478 in vitro.
Teixeira, Erica C N; Ritter, André V; Thompson, Jeffrey Y; Leonard, Ralph H; Swift, Edward J
2004-12-01
To evaluate the effect of tray-based and trayless tooth whitening systems on surface and subsurface microhardness of human enamel. Enamel slabs were obtained from recently extracted human third molars. Specimens were randomly assigned to six groups according to tooth whitening treatment (n = 10): 6.0% hydrogen peroxide (HP) (Crest Whitestrips), 6.5% HP (Crest Professional Whitestrips), 7.5% HP (Day White Excel 3), 9.5% HP (Day White Excel 3), 10% carbamide peroxide (Opalescence), and a control group (untreated). Specimens were treated for 14 days following manufacturers' recommended protocols, and were immersed in artificial saliva between treatments. Enamel surface Knoop microhardness (KHN) was measured immediately before treatment, and at days 1, 7, and 14 of treatment. After treatment, subsurface microhardness was measured at depths of 50-500 microm. Data were analyzed for statistical significance using analysis of variance. Differences in microhardness for treated vs. untreated enamel surface were not statistically significant at any time interval. For 6.5% and 9.5% HP, there was a decrease in surface microhardness values during treatment, but at the end of treatment the microhardness values were not statistically different from the baseline values. For the enamel subsurface values, no differences were observed between treated vs. untreated specimens at each depth. Trayless and tray-based tooth whitening treatments do not significantly affect surface or subsurface enamel microhardness.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cleaver, J.E.; Thomas, G.H.
1988-04-01
A rapid and simple method for determining the sensitivity of human fibroblasts to ultraviolet light is described. As an alternative to the colony formation assay, this method can be used for the rapid diagnosis of ultraviolet light sensitivity in fibroblasts from photosensitive disorders. The method is based on growth of small numbers of cells in 1-cm wells of culture trays for 4 or more days after irradiation and determination of cell survival by the incorporation of (/sup 3/H)hypoxanthine. D37 values (the dose at which 37% of the control level of incorporation remains) obtained from this procedure showed the same relativemore » sensitivity of normal and xeroderma pigmentosum fibroblasts as was obtained by colony formation. Untransformed and SV40-transformed fibroblasts, which have different growth rates and different responses to high cell densities, gave different D37 values by this assay in culture trays as compared with colony formation. Comparison of relative sensitivities to irradiation should therefore be made only between cell types with similar growth characteristics. The similar sensitivity of normal and xeroderma pigmentosum cells to mitomycin C was also determined by this culture tray method. By increasing cell density at the beginning of the experiments, a greater capacity of group C compared with group D fibroblasts for recovery from potentially lethal damage was also detected.« less
Micrometeoroids and debris on LDEF comparison with MIR data
NASA Technical Reports Server (NTRS)
Mandeville, Jean-Claude; Berthoud, Lucinda
1995-01-01
Part of the LDEF tray allocated to French experiments (FRECOPA) has been devoted to the study of dust particles. The tray was located on the face of LDEF directly opposed to the velocity vector. Crater size distributions have made possible the evaluation of the incident microparticle flux in the near-Earth environment. Comparisons are made with measurements obtained on the other faces of LDEF (tray clamps), on the leading edge (MAP) and with results of a similar experiment flown on the MIR space station. The geometry of impact craters, depth in particular, provides useful information on the nature of impacting particles and the correlation of geometry with the chemical analysis of projectile remnants inside craters make possible a discrimination between meteoroids and orbital debris. Emphasis has been laid on the size distribution of small craters in order to assess a cut-off in the distribution of particles in LEO. Special attention has been paid to the phenomenon of secondary impacts. A comparison of flight data with current models of meteoroids and space debris shows a fair agreement for LDEF, except for the smaller particles: the possible contribution of orbital debris in GTO orbits to the LDEF trailing edge flux is discussed. For MIR, flight results show differences with current modeling: the possible enhancement of orbital debris could be due to the contaminating presence of a permanently manned space station.
Accuracy of impressions with different impression materials in angulated implants.
Reddy, S; Prasad, K; Vakil, H; Jain, A; Chowdhary, R
2013-01-01
To evaluate the dimensional accuracy of the resultant (duplicative) casts made from two different impression materials (polyvinyl siloxane and polyether) in parallel and angulated implants. Three definitive master casts (control groups) were fabricated in dental stone with three implants, placed at equi-distance. In first group (control), all three implants were placed parallel to each other and perpendicular to the plane of the cast. In the second and third group (control), all three implants were placed at 10° and 15 o angulation respectively to the long axis of the cast, tilting towards the centre. Impressions were made with polyvinyl siloxane and polyether impression materials in a special tray, using a open tray impression technique from the master casts. These impressions were poured to obtain test casts. Three reference distances were evaluated on each test cast by using a profile projector and compared with control groups to determine the effect of combined interaction of implant angulation and impression materials on the accuracy of implant resultant cast. Statistical analysis revealed no significant difference in dimensional accuracy of the resultant casts made from two different impression materials (polyvinyl siloxane and polyether) by closed tray impression technique in parallel and angulated implants. On the basis of the results of this study, the use of both the impression materials i.e., polyether and polyvinyl siloxane impression is recommended for impression making in parallel as well as angulated implants.
... feet - legs; Ankle swelling; Foot swelling; Leg swelling; Edema - peripheral; Peripheral edema ... 31. Trayes KP, Studdiford JS, Pickle S, Tully AS. Edema: diagnosis and management. Am Fam Physician . 2013;88( ...
The LDEF ultra heavy cosmic ray experiment
NASA Technical Reports Server (NTRS)
Osullivan, D.; Thompson, A.; Bosch, J.; Keegan, R.; Wenzel, K.-P.; Smit, A.; Domingo, C.
1992-01-01
The LDEF Ultra Heavy Cosmic Ray Experiment (UHCRE) used 16 side viewing LDEF trays giving a total geometry factor for high energy cosmic rays of 30 sq m sr. The total exposure factor was 170 sq m sr y. The experiment is based on a modular array of 192 solid state nuclear track detector stacks, mounted in sets of four in 48 pressure vessels. The extended duration of the LDEF mission has resulted in a greatly enhanced potential scientific yield from the UHCRE. Initial scanning results indicate that at least 1800 cosmic ray nuclei with Z greater than 65 were collected, including the world's first statistically significant sample of actinides. Post flight work to date and the current status of the experiment are reviewed.
Space environmental effects on silvered Teflon thermal control surfaces
NASA Technical Reports Server (NTRS)
Hemminger, C. S.; Stuckey, W. K.; Uht, J. C.
1991-01-01
Cumulative space environment effects on Ag/fluorinated ethylene propylene (FEP) were a function of exposure orientation. Samples from nineteen silvered Teflon (Ag/FEP) thermal control surfaces recovered from the Long Duration Exposure Facility (LDEF) were analyzed to determine changes in this material as a function of position on the spacecraft. Although solar absorptance and infrared emittance of measured thermal blanket specimens are relatively unchanged from control specimen values, significant changes in surface morphology, composition and chemistry were observed. Researchers hypothesize that the FEP surfaces on LDEF were degraded by ultraviolet radiation exposure at all orientations, but that the damaged material had been removed by erosion from the blankets exposed to atomic oxygen flux and that contamination is masking the damage on trays flanking the trailing edge.
Rodríguez-Hidalgo, Stephanie; Artés-Hernández, Francisco; Gómez, Perla A; Fernández, Juan Antonio; Artés, Francisco
2010-04-30
Alternative techniques for cultivation of leafy vegetables such as a floating tray system and unconventional gas mixtures for post-harvest active modified atmosphere packaging (MAP) could be of interest in the minimally processed vegetable industry. The combined effect of three pre-harvest fertilisation doses (8, 12 or 16 mmol N L(-1)) and three post-harvest MAP conditions (passive, super-atmospheric or N2O-enriched) on the main quality attributes of fresh-cut baby spinach leaves throughout 10 days at 5 degrees C was studied. After 8 days of shelf life, spinach leaves fertilised with 8 and 16 mmol N L(-1) and stored under N2O-enriched MAP showed the lowest microbial growth, with good sensory quality. Such combined treatments also preserved the total antioxidant capacity sampled at harvest (8 g ascorbic acid equivalent antioxidant capacity kg(-1) f.w.). A decrease of 10-20% in total vitamin C content regardless of N fertilisation and packaging treatment was found during shelf life. Total phenolics content at harvest was 2 g gallic acid equivalents kg(-1) f.w., which was slightly decreased or preserved during shelf life while total chlorophylls were preserved for all treatments assayed around 550 mg kg(-1) f.w. No clear effect of fertilisation doses was observed during post-harvest storage on overall quality of fresh-cut baby spinach leaves, while N2O-enriched atmospheres seems to be a promising alternative to passive MAP for extending shelf life.
21 CFR 876.4730 - Manual gastroenterology-urology surgical instrument and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... forceps cover, biopsy tray without biopsy instruments, line clamp, nonpowered rectal probe, nonelectrical..., gastro-urology probe and director, nonself-retaining retractor, laparotomy rings, nonelectrical snare...
21 CFR 876.4730 - Manual gastroenterology-urology surgical instrument and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... forceps cover, biopsy tray without biopsy instruments, line clamp, nonpowered rectal probe, nonelectrical..., gastro-urology probe and director, nonself-retaining retractor, laparotomy rings, nonelectrical snare...
21 CFR 876.4730 - Manual gastroenterology-urology surgical instrument and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... forceps cover, biopsy tray without biopsy instruments, line clamp, nonpowered rectal probe, nonelectrical..., gastro-urology probe and director, nonself-retaining retractor, laparotomy rings, nonelectrical snare...
21 CFR 876.4730 - Manual gastroenterology-urology surgical instrument and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... forceps cover, biopsy tray without biopsy instruments, line clamp, nonpowered rectal probe, nonelectrical..., gastro-urology probe and director, nonself-retaining retractor, laparotomy rings, nonelectrical snare...
21 CFR 876.4730 - Manual gastroenterology-urology surgical instrument and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... forceps cover, biopsy tray without biopsy instruments, line clamp, nonpowered rectal probe, nonelectrical..., gastro-urology probe and director, nonself-retaining retractor, laparotomy rings, nonelectrical snare...
NASA Technical Reports Server (NTRS)
Lai, Chun-Liang; Greenberg, Paul S.; Chai, An-Ti
1988-01-01
To study thermocapillary flows in a two-dimensional thin liquid layer with heat fluxes imposed on the free surface experimentally, a long tray configuration was employed to simulate the infinite layer. The surface temperature distribution due to thermocapillary convective for different flow regimes was measured and compared with theoretical predictions. A short tray configuration was also employed to study the end wall effects (insulating or conducting). The results show that for a strong convection flow with an insulating wall as the boundary the surface temperature distribution became quite uniform. Consequently, the thermocapillary driving force was greatly reduced. On the other hand, a strong fluid motion always existed adjacent to the conducting wall because of the large surface temperature gradient near the wall.
Interim Status Closure Plan Open Burning Treatment Unit Technical Area 16-399 Burn Tray
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vigil-Holterman, Luciana R.
2012-05-07
This closure plan describes the activities necessary to close one of the interim status hazardous waste open burning treatment units at Technical Area (TA) 16 at the Los Alamos National Laboratory (LANL or the Facility), hereinafter referred to as the 'TA-16-399 Burn Tray' or 'the unit'. The information provided in this closure plan addresses the closure requirements specified in the Code of Federal Regulations (CFR), Title 40, Part 265, Subparts G and P for the thermal treatment units operated at the Facility under the Resource Conservation and Recovery Act (RCRA) and the New Mexico Hazardous Waste Act. Closure of themore » open burning treatment unit will be completed in accordance with Section 4.1 of this closure plan.« less
Waste product profile: Polyethylene terephthalate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, C.
1996-02-01
Polyethylene terephthalate (PET) is a plastic resin used primarily to make bottles. Soft drinks are the primary product packaged in PET. Salad dressing, peanut butter, and other household and consumer products also use PET bottles. PET is also used for film, sheeting for cups and food trays, ovenable trays, and other uses. PET is a relatively new packaging resin, first commercialized in the early `70s. Because it is an ``engineered`` resin, it is more expensive than commodity resins such as high-density polyethylene (HDPE). The primary market for recycled PET is the fiber industry, which uses PET for carpet fiber, sweatersmore » and other clothing, and for other uses. Recycled PET can also be used for food and beverage containers. Export markets, particularly Asian countries, are becoming increasingly important.« less
Apparatus and method for measuring the Seebeck coefficient and resistivity of materials
NASA Technical Reports Server (NTRS)
Hadek, V. (Inventor)
1973-01-01
An apparatus for measuring the thermoelectric properties of materials under high pressure is described that includes a pair of force transmitting assemblies constructed of thermally and electrically conductive material positioned between the ram and anvil of a press. Each force transmitting assembly has a small diameter pressing portion for contacting a face of the sample so that the sample can be squeezed between them. Each assembly also includes a heat exchanger to maintain the sample face at a controlled temperature, and an electrical conductor to carry current generated by the sample. A sleeve of thermally and electrically insulative material closely surrounds the pressing portions of the two assemblies.
Zweigenbaum, J; Henion, J
2000-06-01
The high-throughput determination of small molecules in biological matrixes has become an important part of drug discovery. This work shows that increased throughput LC/MS/MS techniques can be used for the analysis of selected estrogen receptor modulators in human plasma where more than 2000 samples may be analyzed in a 24-h period. The compounds used to demonstrate the high-throughput methodology include tamoxifen, raloxifene, 4-hydroxytamoxifen, nafoxidine, and idoxifene. Tamoxifen and raloxifene are used in both breast cancer therapy and osteoporosis and have shown prophylactic potential for the reduction of the risk of breast cancer. The described strategy provides LC/MS/MS separation and quantitation for each of the five test articles in control human plasma. The method includes sample preparation employing liquid-liquid extraction in the 96-well format, an LC separation of the five compounds in less than 30 s, and selected reaction monitoring detection from low nano- to microgram per milliter levels. Precision and accuracy are determined where each 96-well plate is considered a typical "tray" having calibration standards and quality control (QC) samples dispersed through each plate. A concept is introduced where 24 96-well plates analyzed in 1 day is considered a "grand tray", and the method is cross-validated with standards placed only at the beginning of the first plate and the end of the last plate. Using idoxifene-d5 as an internal standard, the results obtained for idoxifene and tamoxifen satisfy current bioanalytical method validation criteria on two separate days where 2112 and 2304 samples were run, respectively. Method validation included 24-h autosampler stability and one freeze-thaw cycle stability for the extracts. Idoxifene showed acceptable results with accuracy ranging from 0.3% for the high quality control (QC) to 15.4% for the low QC and precision of 3.6%-13.9% relative standard deviation. Tamoxifen showed accuracy ranging from 1.6% to 13.8% and precision from 7.8% to 15.2%. The linear dynamic range for these compounds was 3 orders of magnitude. The limit of quantification was 5 and 50 ng/ mL for tamoxifen and idoxifene, respectively. The other compounds in this study in general satisfy the more relaxed bioanalytical acceptance criteria for modern drug discovery. It is suggested that the quantification levels reported in this high-throughput analysis example are adequate for many drug discovery and related early pharmaceutical studies.
Evaluation of the impact of RNA preservation methods of spiders for de novo transcriptome assembly.
Kono, Nobuaki; Nakamura, Hiroyuki; Ito, Yusuke; Tomita, Masaru; Arakawa, Kazuharu
2016-05-01
With advances in high-throughput sequencing technologies, de novo transcriptome sequencing and assembly has become a cost-effective method to obtain comprehensive genetic information of a species of interest, especially in nonmodel species with large genomes such as spiders. However, high-quality RNA is essential for successful sequencing, and sample preservation conditions require careful consideration for the effective storage of field-collected samples. To this end, we report a streamlined feasibility study of various storage conditions and their effects on de novo transcriptome assembly results. The storage parameters considered include temperatures ranging from room temperature to -80°C; preservatives, including ethanol, RNAlater, TRIzol and RNAlater-ICE; and sample submersion states. As a result, intact RNA was extracted and assembly was successful when samples were preserved at low temperatures regardless of the type of preservative used. The assemblies as well as the gene expression profiles were shown to be robust to RNA degradation, when 30 million 150-bp paired-end reads are obtained. The parameters for sample storage, RNA extraction, library preparation, sequencing and in silico assembly considered in this work provide a guideline for the study of field-collected samples of spiders. © 2015 John Wiley & Sons Ltd.
Bashir, Mina; Ahmed, Mahjabeen; Weinmaier, Thomas; Ciobanu, Doina; Ivanova, Natalia; Pieber, Thomas R.; Vaishampayan, Parag A.
2016-01-01
Strict planetary protection practices are implemented during spacecraft assembly to prevent inadvertent transfer of earth microorganisms to other planetary bodies. Therefore, spacecraft are assembled in cleanrooms, which undergo strict cleaning and decontamination procedures to reduce total microbial bioburden. We wanted to evaluate if these practices selectively favor survival and growth of hardy microorganisms, such as pathogens. Three geographically distinct cleanrooms were sampled during the assembly of three NASA spacecraft: The Lockheed Martin Aeronautics' Multiple Testing Facility during DAWN, the Kennedy Space Center's Payload Hazardous Servicing Facility (KSC-PHSF) during Phoenix, and the Jet Propulsion Laboratory's Spacecraft Assembly Facility during Mars Science Laboratory. Sample sets were collected from the KSC-PHSF cleanroom at three time points: before arrival of the Phoenix spacecraft, during the assembly and testing of the Phoenix spacecraft, and after removal of the spacecraft from the KSC-PHSF facility. All samples were subjected to metagenomic shotgun sequencing on an Illumina HiSeq 2500 platform. Strict decontamination procedures had a greater impact on microbial communities than sampling location Samples collected during spacecraft assembly were dominated by Acinetobacter spp. We found pathogens and potential virulence factors, which determine pathogenicity in all the samples tested during this study. Though the relative abundance of pathogens was lowest during the Phoenix assembly, potential virulence factors were higher during assembly compared to before and after assembly, indicating a survival advantage. Decreased phylogenetic and pathogenic diversity indicates that decontamination and preventative measures were effective against the majority of microorganisms and well implemented, however, pathogen abundance still increased over time. Four potential pathogens, Acinetobacter baumannii, Acinetobacter lwoffii, Escherichia coli and Legionella pneumophila, and their corresponding virulence factors were present in all cleanroom samples. This is the first functional metagenomics study describing presence of pathogens and their corresponding virulence factors in cleanroom environments. The results of this study should be considered for microbial monitoring of enclosed environments such as schools, homes, hospitals and more isolated habitation such the International Space Station and future manned missions to Mars. PMID:27667984
ERIC Educational Resources Information Center
Kimbrough, T. Daniel; Llewellyn, Gerald C.
1973-01-01
Describes a surgical technique for performing pinealectomics, applicable to classroom and laboratory studies, by using a head-holding device for small animals and a flat dissecting tray outfitted with holding straps for larger animals. (CC)
Code of Federal Regulations, 2013 CFR
2013-10-01
..., must be capable of withstanding, without leakage or rupture, an internal pressure of at least two times... plastic tray, a plastic, fiberboard or paperboard partition must be used to prevent friction between the...
Code of Federal Regulations, 2012 CFR
2012-10-01
..., must be capable of withstanding, without leakage or rupture, an internal pressure of at least two times... plastic tray, a plastic, fiberboard or paperboard partition must be used to prevent friction between the...
Mehra, Mamta; Vahidi, Farhad; Berg, Robert W
2014-06-01
The purpose of the study was to survey program directors of postdoctoral prosthodontic programs in the United States regarding their programs' complete denture impression techniques. The key objectives of the survey were to identify the current trends in complete denture impression making and to determine which techniques and materials are taught in US postdoctoral prosthodontic programs. An online survey was sent to all program directors of US postdoctoral prosthodontic programs. The survey comprised two sections: preliminary impressions and final impressions. The survey contained 22 questions that would take approximately 5 minutes to complete. All responses remained anonymous throughout the survey. The response rate for the survey was 87%. A majority of the programs did not separately border mold the tray prior to making the preliminary impressions (82%). The impression material of choice for the preliminary impression was irreversible hydrocolloid (88%). Selective pressure was the predominantly used impression philosophy (80%). All programs border molded the custom tray, and 95% recorded the borders in sections. The material of choice for border molding the custom tray was modeling plastic impression compound (71%). The most commonly used impression material for the final impressions was polyvinylsiloxane (PVS) (42%), and the second most commonly used impression material was polysulphide (32%). The most common technique for locating the posterior palatal seal was marking intraorally and transferring onto the final impression (65%). Most programs routinely advised their patients not to wear their existing dentures for at least 24 hours before the final impressions were made (83%). Based on the results of this study, the following conclusions can be drawn: (1) The most commonly used material for the preliminary impression was irreversible hydrocolloid and for the final impression was PVS. (2) Modeling plastic impression compound was used by most programs to border mold the custom trays. (3) Selective pressure was the predominantly used impression philosophy. (4) A majority of the programs made a special consideration for excessive movable (flabby) tissue. (5) Most programs routinely advised their patients to not wear their existing dentures for at least 24 hours before the final impressions were made. © 2013 by the American College of Prosthodontists.
NASA Astrophysics Data System (ADS)
Stark, N.; Hay, A. E.; Cheel, R.; Lake, C. B.
2014-08-01
The impact of particle shape on the angle of internal friction, and the resulting impact on beach sediment dynamics, is still poorly understood. In areas characterized by sediments of specific shape, particularly non-rounded particles, this can lead to large departures from the expected sediment dynamics. The steep slope (1 : 10) of the mixed sand-gravel beach at Advocate Harbour is stable in large-scale morphology over decades, despite a high tidal range of 10 m or more, and intense shore-break action during storms. The Advocate sand (d < 2 mm) was found to have an elliptic, plate-like shape (Corey Shape Index, CSI ≈ 0.2-0.6). High angles of internal friction of this material were determined using direct shear, ranging from φ ≈ 41 to 49°, while the round to angular gravel was characterized as φ = 33°. The addition of 25% of the elliptic plate-like sand-sized material to the gravel led to an immediate increase in friction angle to φ = 38°. Furthermore, re-organization of the particles occurred during shearing, characterized by a short phase of settling and compaction, followed by a pronounced strong dilatory behavior and an accompanying strong increase of resistance to shear and, thus, shear stress. Long-term shearing (24 h) using a ring shear apparatus led to destruction of the particles without re-compaction. Finally, submerged particle mobilization was simulated using a tilted tray submerged in a water-filled tank. Despite a smooth tray surface, particle motion was not initiated until reaching tray tilt angles of 31° and more, being ≥7° steeper than for motion initiation of the gravel mixtures. In conclusion, geotechnical laboratory experiments quantified the important impact of the elliptic, plate-like shape of Advocate Beach sand on the angles of internal friction of both pure sand and sand-gravel mixtures. The resulting effect on initiation of particle motion was confirmed in tilting tray experiments. This makes it a vivid example of how particle shape can contribute to the stabilization of the beach face.
Yonkman, Janell; O'Neil, Joseph; Talty, Judith; Bull, Marilyn J
2010-01-01
We compared observed and reported practice among children with special health care needs transported in wheelchairs with the recommendations from the American National Standards Institute/Rehabilitation Engineering and Assistive Technology Society of North America Committee on Wheelchairs and Transportation voluntary standards for best practice for using wheelchairs in vehicles. A convenience sample of vehicles exiting the garage of a children's hospital was observed. Certified child passenger safety technicians gathered driver demographics and the child's reported medical condition, weight, age, clinic visited, and relation to the driver. Technicians observed how the wheelchair and occupant were secured. A sample of 20 vehicles showed that 90% used four-point tie-down systems to secure the wheelchairs. A total of 88% of drivers tied the wheelchairs down correctly; only 20% used a separate lap-shoulder belts to secure the occupants. Twenty-five percent used lap trays, which are not recommended. Fifteen participants traveled with medical equipment secured inappropriately. Many deviations from best practice were observed and highlight areas for increased awareness, education, and resources for caregivers.
The Preliminary Examination of Organics in the Returned Stardust Samples from Comet Wild 2
NASA Technical Reports Server (NTRS)
Sandford, S. A.; Aleon, J.; Alexander, C.; Butterworth, A.; Clemett, S. J.; Cody, G.; Cooper, G.; Dworkin, J. P.; Flynn, G. J.; Gilles, M. K.
2006-01-01
The primary objective of STARDUST is to collect coma samples from comet 8lP/Wild 2. These samples were collected by impact onto aerogel tiles on Jan 2, 2004 when the spacecraft flew through the comet's coma at a relative velocity of about 6.1 km/sec. Measurements of dust impacts on the front of the spacecraft suggest that the aerogel particle collector was impacted by 2800 +/- 500 particles larger than 15 micron in diameter. Following recovery of the Sample Return Capsule (SRC) on Jan 15, 2006, the aerogel collector trays will be removed in a clean room at JSC. After documentation of the collection, selected aerogel tiles will be removed and aerogel and cometary samples will be extracted for study. A number of different extraction techniques will be used, each optimized for the analytical technique that is to be used. The STARDUST Mission will carry out a 6 month preliminary examination (PE) of a small portion of the returned samples. The examination of the samples will be made by a number of subteams that will concentrate on specific aspects of the samples. One of these is the Organics PE Team (see the author list above for team members). These team members will use a number of analytical techniques to produce a preliminary characterization of the abundance and nature of the organics (if any) in the returned samples.
... highest possible level. • Prevent Accidents and Injury: Recommending lighting that will be most effective for a particular ... other equipment contrasts with the wall. Maintain good lighting in walkways, hallways, stairwells, etc. Use labeled tray ...
7 CFR 51.1216 - Size requirements.
Code of Federal Regulations, 2013 CFR
2013-01-01
...) The numerical count or a count-size based on equivalent tray pack size designations or the minimum... numerical count is not shown the minimum diameter shall be plainly stamped, stenciled, or otherwise marked...
7 CFR 51.1216 - Size requirements.
Code of Federal Regulations, 2014 CFR
2014-01-01
...) The numerical count or a count-size based on equivalent tray pack size designations or the minimum... numerical count is not shown the minimum diameter shall be plainly stamped, stenciled, or otherwise marked...
14 CFR 121.215 - Cabin interiors.
Code of Federal Regulations, 2013 CFR
2013-01-01
... compartment where smoking is to be allowed must be equipped with self-contained ash trays that are completely removable and other compartments must be placarded against smoking. (e) Each receptacle for used towels...
14 CFR 121.215 - Cabin interiors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... compartment where smoking is to be allowed must be equipped with self-contained ash trays that are completely removable and other compartments must be placarded against smoking. (e) Each receptacle for used towels...
14 CFR 121.215 - Cabin interiors.
Code of Federal Regulations, 2012 CFR
2012-01-01
... compartment where smoking is to be allowed must be equipped with self-contained ash trays that are completely removable and other compartments must be placarded against smoking. (e) Each receptacle for used towels...
14 CFR 121.215 - Cabin interiors.
Code of Federal Regulations, 2011 CFR
2011-01-01
... compartment where smoking is to be allowed must be equipped with self-contained ash trays that are completely removable and other compartments must be placarded against smoking. (e) Each receptacle for used towels...
Microtrap assembly for greenhouse gas and air pollution monitoring
Mitra, Somenath; Saridara, Chutarat
2015-08-25
A microtrap assembly includes a carbon nanotube sorbent. The microtrap assembly may be employed as a preconcentrator operable to deliver a sample to an analytical device to measure the concentrations of greenhouse gases. A system includes a microtrap having a carbon nanotube sorbent for measuring the concentrations of greenhouse gases in a sample.
12. COLD CALIBRATION BLOCKHOUSE BASEMENT VIEW FROM LEFT TO RIGHT, ...
12. COLD CALIBRATION BLOCKHOUSE BASEMENT VIEW FROM LEFT TO RIGHT, CABLE TRAYS, RACKS, CABLE CONNECTION TERMINALS. - Marshall Space Flight Center, East Test Area, Cold Calibration Test Stand, Huntsville, Madison County, AL
7 CFR 51.3152 - Standard pack.
Code of Federal Regulations, 2010 CFR
2010-01-01
... with cell compartments, cardboard fillers or molded trays shall be of the proper size for the cells.... (g) “Diameter” means the greatest dimension measured at right angles to a line from stem to blossom...
7 CFR 989.110 - Varietal types.
Code of Federal Regulations, 2011 CFR
2011-01-01
... trays or on the vine, with or without the application of a drying agent that is a food-grade additive...) Dipped Seedless includes all raisins produced by artificial dehydration of seedless grapes that possess...
7 CFR 989.110 - Varietal types.
Code of Federal Regulations, 2010 CFR
2010-01-01
... trays or on the vine, with or without the application of a drying agent that is a food-grade additive...) Dipped Seedless includes all raisins produced by artificial dehydration of seedless grapes that possess...
ERIC Educational Resources Information Center
Hammond, Edward; Hall, John
1998-01-01
Examines the need for power reliability when educational facilities incorporate communications infrastructures. Telecommunications equipment placement and environmental conditions are addressed, as are the integrating of cable trays and conduit systems, developing surge-suppression, and building grounding systems. (GR)
21 CFR 884.1550 - Amniotic fluid sampler (amniocentesis tray).
Code of Federal Regulations, 2011 CFR
2011-04-01
... accessories, such as vials, specimen containers, medium, drapes, etc. The device is used at 16-18 weeks... when used to assess fetal maturity. (b) Classification. Class I (general controls). The device is...
21 CFR 884.1550 - Amniotic fluid sampler (amniocentesis tray).
Code of Federal Regulations, 2010 CFR
2010-04-01
... accessories, such as vials, specimen containers, medium, drapes, etc. The device is used at 16-18 weeks... when used to assess fetal maturity. (b) Classification. Class I (general controls). The device is...
Accommodation and Compliance Series: Employees with Arthritis
... handed keyboard, an articulating keyboard tray, speech recognition software, a trackball, and office equipment for a workstation ... space heater, additional window insulation, and speech recognition software. An insurance clerk with arthritis from systemic lupus ...
7 CFR 51.3152 - Standard pack.
Code of Federal Regulations, 2012 CFR
2012-01-01
... with cell compartments, cardboard fillers or molded trays shall be of the proper size for the cells.... (g) “Diameter” means the greatest dimension measured at right angles to a line from stem to blossom...
7 CFR 51.3152 - Standard pack.
Code of Federal Regulations, 2011 CFR
2011-01-01
... with cell compartments, cardboard fillers or molded trays shall be of the proper size for the cells.... (g) “Diameter” means the greatest dimension measured at right angles to a line from stem to blossom...
On the analysis of activation energy of PS 35000 in various solvents
NASA Astrophysics Data System (ADS)
Padmanaban, R.; Venkatramanan, K.
2015-08-01
Polymer is a macromolecule, composed of many repeated subunits. Polystyrene is a polymer of styrene. Polystyrene has very low impact strength. Polystyrene generally leads to lower tensile strength, crystal grades being stiff and brittle. It is used to construct clamshell packs, cookie trays, cups, forks, spoons, cushioning materials for packaging, disposable medical devices, egg cartons, fast food containers, lids, lunch boxes, meat trays and also used in civil construction (concrete form-work or weight reduction on foundations). In the present study an attempt has been made to compute the viscosity of Polystyrene (PS 35000) in toluene and benzene in different concentrations (0.5%, 1.0%, 1.5%, 2.0% & 2.5%) at different temperatures (303 K, 308 K, 313 K & 318 K). From these experimental data the activation energy is calculated and the effect of solvent is analysed.
2. RW Meyer Sugar Mill: 18761899. Threeroll sugar mill, oneton ...
2. RW Meyer Sugar Mill: 1876-1899. Three-roll sugar mill, one-ton daily processing capacity. Manufactured by Edwin Maw, Liverpool, England, ca. 1855-1870. View: Top roll and one bottom roll, mill housing or cheeks, and spur pinion gears. The broken projection on the mill beside the bottom roll indicates the location of the cane tray. The cane juice crushed from the cane flowed into the juice tray below the bottom rolls. It then flowed into a wooden gutter and through a short tunnel in the mill's masonry enclosure and on to the boiling house for further processing. The opening at the base of the masency wall (In the photograph) is where the gutter ran from the mill to the boiling house. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI
Seeds in space experiment results
NASA Technical Reports Server (NTRS)
Alston, Jim A.
1991-01-01
Two million seeds of 120 different varieties representing 106 species, 97 genera, and 55 plant families were flown aboard the Long Duration Exposure Facility (LDEF). The seeds were housed on the space exposed experiment developed for students (SEEDS) tray in sealed canister number six and in two small vented canisters. The tray was in the F-2 position. The seeds were germinated and the germination rates and development of the resulting plants compared to the control seed that stayed in Park Seed's seed storage facility. The initial results are presented. There was a better survival rate in the sealed canister in space than in the storage facility at Park Seed. At least some of the seeds in each of the vented canisters survived the exposure to vacuum for almost six years. The number of observed apparent mutations was very low.
Idris, Ayman Salih Omer; Pandey, Ashok; Rao, S S; Sukumaran, Rajeev K
2017-10-01
The production of cellulase by Trichoderma reesei RUT C-30 under solid-state fermentation (SSF) on wheat bran and cellulose was optimized employing a two stage statistical design of experiments. Optimization of process parameters resulted in a 3.2-fold increase in CMCase production to 959.53IU/gDS. The process was evaluated at pilot scale in tray fermenters and yielded 457IU/gDS using the lab conditions and indicating possibility for further improvement. The cellulase could effectively hydrolyze alkali pretreated sorghum stover and addition of Aspergillus niger β-glucosidase improved the hydrolytic efficiency 174%, indicating the potential to use this blend for effective saccharification of sorghum stover biomass. The enzymatic hydrolysate of sorghum stover was fermented to ethanol with ∼80% efficiency. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Blakkolb, Brian K.; Yaung, James Y.; Henderson, Kelly A.; Taylor, William W.; Ryan, Lorraine E.
1992-01-01
The Space Plasma-High Voltage Drainage Experiment (SP-HVDE) provided a unique opportunity to study long term space environmental effects on materials because it was comprised of two identical experimental trays; one tray located on the ram facing side (D-10), and the other on the wake facing side (B-4) of the LDEF. This configuration allows for the comparison of identical materials exposed to two distinctly different environments. The purpose of this work is to document an assessment of the effects of five and three quarters years of low Earth orbital space exposure on materials comprising the SP-HVDE (experiment no. A0054). The findings of the materials investigation reported focus on atomic oxygen effects, micrometeor and debris impact site documentation, thermal property measurements, and environmentally induced contamination.
NASA Technical Reports Server (NTRS)
Lheureux, J.; Fan, C. Y.; Mainardi, R.; Gloeckler, G.
1974-01-01
A 6500 sq cm-ster cosmic-ray detector consisting of 12 gas counter trays sandwiched between two large-area circular scintillation counters was flown from Palestine, Texas in November 1972 to study the composition of primary particles greater than 1.5 GeV/nucleon in the charge range from 3 to 30. For each analyzed event, the particle trajectory was recorded, using four 20-wire proportional counter trays. Also recorded were the energy loss in each of the solid counters and the dE/dx losses in each of the 12 gas counters. The large dynamic range of the detector is established by operating six of the gas counters in the ionization mode. A description of the instrument and some preliminary results are given.
NASA Technical Reports Server (NTRS)
Lheureux, J.; Fan, C. Y.; Gloeckler, G.; Mainardi, R.
1973-01-01
A 6500 sq cm-ster cosmic ray detector consisting of twelve gas counter trays sandwiched between two large area circular scintillation counters was flown from Palestine, Texas in November of 1972 to study the composition of primary particles 1.5 GeV/nucleon in the charge range 3 to 30. For each analyzed event, a recording was made of (1) the particle trajectory using four 20 wire proportional counter trays, (2) the energy loss in each of the solid counters, and (3) the dE/dx losses in each of the twelve gas counters. The large dynamic range of the detector is established by operating six of the gas counters in the ionization mode. A description of the instrument and some preliminary results are given.
Inui, Hiroshi; Taketomi, Shuji; Yamagami, Ryota; Sanada, Takaki; Shirakawa, Nobuyuki; Tanaka, Sakae
2016-07-01
Tilting of the mobile bearing relative to the tibial tray in the flexion position may result from the implantation of femoral components more laterally relative to tibial components during unicompartmental knee arthroplasty (UKA) using the Oxford Knee. The purpose of the present study was to compare femoral component positions after UKA using the phase 3 device and a novel device. We further evaluated the placement of the femoral components with the new device in the flexion position to determine the association with short-term prognosis. The location of femoral and tibial components in the flexion position of 38 knees implanted using the phase 3 device and 49 knees using a novel device was assessed at 1 year postoperatively using radiography of the proximal tibia and distal femur in the flexion position. The femoral component was implanted more laterally using the new device than using the phase 3 device in the flexion position (P = .012), which caused the impingement of the mobile bearing against the lateral wall of the tibial tray. After UKA using the new device, 10% of patients exhibited the tilting phenomenon of the mobile bearing because of the lateral implantation of the femoral implant. To prevent implantation of the femoral component too laterally using the new device during UKA, knee surgeons should set the drill guide more medially such that the center of the drill is aligned with the middle of the medial femoral condyle. Copyright © 2016 Elsevier Inc. All rights reserved.
Importance of analytically verifying chemical treatments
Rach, J.J.; Gaikowski, M.P.; Olson, J.J.
1997-01-01
Hydrogen peroxide is considered a low regulatory priority compound by the U.S. Food and Drug Administration. It is used to control fungal infections on fish eggs. We studied the treatment profiles of hydrogen peroxide in Heath, McDonald egg jar, and Clark-Williamson incubators during treatments intended to deliver an effective regimen of at least 500 ??L hydrogen peroxide/L (i.e., treatments of 500 and 1,000 ??L/L) for 15 min. Hydrogen peroxide concentrations decreased with increasing distance from the influent water in both Heath and Clark-Williamson incubators. The top treatment tray (tray 2) of the Heath incubator received more than 90% of the intended regimen during the 500 ??L/L treatment, whereas at 1,000 ??L/L, all trays had hydrogen peroxide concentrations at or above 500 ??L/L for 15 min. None of the compartments in the Clark-Williamson incubator received the intended therapeutic regimen when treated at 500 ??L/L. The McDonald egg jar system distributed the intended concentration for the designated treatment period in all jars, except those located directly below the influent water. Our results indicate that dilution of therapeutants applied through certain egg incubation systems significantly decreases the efficacy of treatments and may render them ineffective. The dilution characteristics of egg incubation systems should be assessed in order to ensure proper delivery of all intended chemical concentrations and exposure regimens. Suggestions for maintaining the minimum effective concentrations in evaluated incubators are included.
Applying Henry`s Law to groundwater treatment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chidgopkar, V.R.
Air strippers are very popular equipment for mass transfer where air and water are contacted and the contaminants are transferred from water into the air phase. In a typical air-stripper arrangement, water flows from the top and air is blown from the bottom. The increase in surface area between the air and the water phases increases the removal efficiency. In packed towers, high-surface-area packing materials are used to that end. In a sieve tray tower, water flows across the tray through channels separated by baffles and air flows from the bottom, up through holes in the tray. In diffused aerators,more » air is introduced through a bubbler or a nozzle into the water stream. All these units are commercially available. Several environmental consulting and remediation engineering firms use Henry`s Law to predict the stripping performance of volatile and semi-volatile contaminants present using the above equipment. Extensive work has been done during the past few decades to determine Henry`s Law constant, H. Different procedures are reported in the literature to determine henry`s Law constant for various chemicals from the experimental data and from empirical correlations. This article discusses the reasons why so much error is observed in reported values of henry`s Law constants in the literature--the effect of various parameters such as temperature, co-solubility, etc., on H value. A modified experimental procedure to measure Henry`s Law constant is presented, then the law is applied in predicting stripping performance of various chemicals.« less
Staneck, J L; Allen, S D; Harris, E E; Tilton, R C
1985-01-01
The Sensititre Autoreader is a microcomputer-driven instrument capable of automatically reading antimicrobial susceptibility microdilution trays. The instrument measures the fluorescence liberated by bacterial enzymatic activity on fluorogenic substrates as an indicator of growth in each well. A mathematical algorithm converts the fluorescent signals from an antimicrobial dilution series to an MIC endpoint. A three-center study evaluated the performance of the Autoreader in comparison with MIC determined visually in a duplicate set of control plates lacking fluorogenic substrate. Among 828 isolates of gram-negative bacilli tested against 17 antimicrobial agents, Autoreader 18-h MIC were within +/- 1 twofold dilution of control MIC values (agreement) in 95.3% of instances. In 3.5% of the instances, Autoreader values occurred +/- 2 half-step dilutions from control values (minor discrepancy), and in only 1.2% of instances did Autoreader values deviate from control values by greater than +/- 2 dilution steps (major discrepancy). Agreement, minor discrepancies, and major discrepancies were noted among 148 gram-positive cocci tested against 11 antimicrobial agents in 93.5, 4.8, and 1.7% of the instances, respectively. Over half of the major discrepancies noted with gram-negative bacilli occurred with Proteus mirabilis-beta-lactam combinations, a problem that was resolved when a lower initial inoculum was used. Inter-and intralaboratory reproducibility was excellent. Standard Sensititre susceptibility trays may be instrument read at 18 h reproducibly and accurately with only slight modification of conventional procedures to include fluorogenic enzyme substrates in the incubation broth. PMID:4031033
Second LDEF Post-Retrieval Symposium interim results of experiment A0034
NASA Technical Reports Server (NTRS)
Linton, Roger C.; Kamenetzky, Rachel R.
1993-01-01
Thermal control coatings and contaminant collector mirrors were exposed on the leading and trailing edge modules of Long Duration Exposure Facility (LDEF) experiment A0034 to provide a basis of comparison for investigating the role of atomic oxygen in the stimulation of volatile outgassing products. The exposure of identical thermal coatings on both the leading and trailing edges of the LDEF and the additional modified exposure of identical coatings under glass windows and metallic covers in each of the flight modules provided multiple combinations of space environmental exposure to the coatings and the contaminant collector mirrors. Investigations were made to evaluate the effects of the natural space and the induced environments on the thermal coatings and the collector mirrors to differentiate the sources of observed material degradation. Two identical flight units were fabricated for the LDEF mission, each of which included twenty-five thermal control coatings mounted in isolated compartments, each with an adjacent contaminant collector mirror mounted on the wall. The covers of the flight units included apertures for each compartment, exposing the thermal coatings directly to the space environment. Six of these compartments were sealed with ultraviolet-grade transmitting quartz windows and four other compartments were sealed with aluminum covers. One module of this passive LDEF experiment, occupying one-sixth of a full tray, was mounted in Tray C9 (leading edge), while the other identical module was mounted in Tray C3 (trailing edge).
Van Berkel, Gary J.; Weiskittel, Taylor M.; Kertesz, Vilmos
2014-11-07
Droplet-based liquid microjunction surface sampling coupled with high-performance liquid chromatography (HPLC)-electrospray ionization (ESI)-tandem mass spectrometry (MS/MS) for spatially resolved analysis provides the possibility of effective analysis of complex matrix samples and can provide a greater degree of chemical information from a single spot sample than is typically possible with a direct analysis of an extract. Described here is the setup and enhanced capabilities of a discrete droplet liquid microjunction surface sampling system employing a commercially available CTC PAL autosampler. The system enhancements include incorporation of a laser distance sensor enabling unattended analysis of samples and sample locations of dramatically disparatemore » height as well as reliably dispensing just 0.5 μL of extraction solvent to make the liquid junction to the surface, wherein the extraction spot size was confined to an area about 0.7 mm in diameter; software modifications improving the spatial resolution of sampling spot selection from 1.0 to 0.1 mm; use of an open bed tray system to accommodate samples as large as whole-body rat thin tissue sections; and custom sample/solvent holders that shorten sampling time to approximately 1 min per sample. Lastly, the merit of these new features was demonstrated by spatially resolved sampling, HPLC separation, and mass spectral detection of pharmaceuticals and metabolites from whole-body rat thin tissue sections and razor blade (“crude”) cut mouse tissue.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Berkel, Gary J.; Weiskittel, Taylor M.; Kertesz, Vilmos
Droplet-based liquid microjunction surface sampling coupled with high-performance liquid chromatography (HPLC)-electrospray ionization (ESI)-tandem mass spectrometry (MS/MS) for spatially resolved analysis provides the possibility of effective analysis of complex matrix samples and can provide a greater degree of chemical information from a single spot sample than is typically possible with a direct analysis of an extract. Described here is the setup and enhanced capabilities of a discrete droplet liquid microjunction surface sampling system employing a commercially available CTC PAL autosampler. The system enhancements include incorporation of a laser distance sensor enabling unattended analysis of samples and sample locations of dramatically disparatemore » height as well as reliably dispensing just 0.5 μL of extraction solvent to make the liquid junction to the surface, wherein the extraction spot size was confined to an area about 0.7 mm in diameter; software modifications improving the spatial resolution of sampling spot selection from 1.0 to 0.1 mm; use of an open bed tray system to accommodate samples as large as whole-body rat thin tissue sections; and custom sample/solvent holders that shorten sampling time to approximately 1 min per sample. Lastly, the merit of these new features was demonstrated by spatially resolved sampling, HPLC separation, and mass spectral detection of pharmaceuticals and metabolites from whole-body rat thin tissue sections and razor blade (“crude”) cut mouse tissue.« less
Contamination of optical surfaces in Earth orbit
NASA Technical Reports Server (NTRS)
Kinser, Donald L.; Weller, Robert A.; Mendenhall, M. H.; Wiedlocher, D. E.; Nichols, R.; Tucker, D.; Whitaker, A.
1992-01-01
Glass and glass ceramic samples exposed to the low earth orbit environment for approximately 5.5 years on the Long Duration Exposure Facility (LDEF) were found to display limited degradation in optical transmission. Commercial optical quality fused silica samples display decreases in transmission in the 200 to 400 nm wavelength region, and this degradation appears to be a consequence of surface contamination. The contamination, found only on internal surfaces of samples, was measured by medium energy backscattering spectrometry and found to be primarily carbon. Additional thin film contamination by a species with atomic mass near 64, which was present at the level of about 8 x 10 exp 14/sq. cm has not been identified. These observations are consistent with the interpretation that organic binders used in the black absorbing paint (Chem Glaze Z-306) inside the sample holding tray were concentrated in the vicinity of the samples and photolytically cracked by solar UV radiation. The resulting decomposition products were deposited on the interior sample surface and gave rise to the optical transmission loss. No detectable contamination was observed on the external or space exposed surface of the samples. No measurable damage was detected which could be attributed to the direct action of gamma or UV radiation on the glass samples. These results emphasize the need for special precautions in the preparation of spacecraft carrying precision optical components on long duration missions.
The Properties of the Massive Star-forming Galaxies with an Outside-in Assembly Mode
NASA Astrophysics Data System (ADS)
Wang, Enci; Kong, Xu; Wang, Huiyuan; Wang, Lixin; Lin, Lin; Gao, Yulong; Liu, Qing
2017-08-01
Previous findings show that massive ({M}* > {10}10 {M}⊙ ) star-forming (SF) galaxies usually have an “inside-out” stellar mass assembly mode. In this paper, we have for the first time selected a sample of 77 massive SF galaxies with an “outside-in” assembly mode (called the “targeted sample”) from the Mapping Nearby Galaxies at the Apache Point Observatory (MaNGA) survey. For comparison, two control samples are constructed from the MaNGA sample matched in stellar mass: a sample of 154 normal SF galaxies and a sample of 62 quiescent galaxies. In contrast to normal SF galaxies, the targeted galaxies appear to be smoother and more bulge-dominated and have a smaller size and higher concentration, star formation rate, and gas-phase metallicity as a whole. However, they have a larger size and lower concentration than quiescent galaxies. Unlike the normal SF sample, the targeted sample exhibits a slightly positive gradient of the 4000 Å break and a pronounced negative gradient of Hα equivalent width. Furthermore, the median surface mass density profile is between those of the normal SF and quiescent samples, indicating that the gas accretion of quiescent galaxies is not likely to be the main approach for the outside-in assembly mode. Our results suggest that the targeted galaxies are likely in the transitional phase from normal SF galaxies to quiescent galaxies, with rapid ongoing central stellar mass assembly (or bulge growth). We discuss several possible formation mechanisms for the outside-in mass assembly mode.
Sampling scheme for pyrethroids on multiple surfaces on commercial aircrafts
MOHAN, KRISHNAN R.; WEISEL, CLIFFORD P.
2015-01-01
A wipe sampler for the collection of permethrin from soft and hard surfaces has been developed for use in aircraft. “Disinsection” or application of pesticides, predominantly pyrethrods, inside commercial aircraft is routinely required by some countries and is done on an as-needed basis by airlines resulting in potential pesticide dermal and inhalation exposures to the crew and passengers. A wipe method using filter paper and water was evaluated for both soft and hard aircraft surfaces. Permethrin was analyzed by GC/MS after its ultrasonication extraction from the sampling medium into hexane and volume reduction. Recoveries, based on spraying known levels of permethrin, were 80–100% from table trays, seat handles and rugs; and 40–50% from seat cushions. The wipe sampler is easy to use, requires minimum training, is compatible with the regulations on what can be brought through security for use on commercial aircraft, and readily adaptable for use in residential and other settings. PMID:19756041
The coffee-machine bacteriome: biodiversity and colonisation of the wasted coffee tray leach
Vilanova, Cristina; Iglesias, Alba; Porcar, Manuel
2015-01-01
Microbial communities are ubiquitous in both natural and artificial environments. However, microbial diversity is usually reduced under strong selection pressures, such as those present in habitats rich in recalcitrant or toxic compounds displaying antimicrobial properties. Caffeine is a natural alkaloid present in coffee, tea and soft drinks with well-known antibacterial properties. Here we present the first systematic analysis of coffee machine-associated bacteria. We sampled the coffee waste reservoir of ten different Nespresso machines and conducted a dynamic monitoring of the colonization process in a new machine. Our results reveal the existence of a varied bacterial community in all the machines sampled, and a rapid colonisation process of the coffee leach. The community developed from a pioneering pool of enterobacteria and other opportunistic taxa to a mature but still highly variable microbiome rich in coffee-adapted bacteria. The bacterial communities described here, for the first time, are potential drivers of biotechnologically relevant processes including decaffeination and bioremediation. PMID:26592442
The coffee-machine bacteriome: biodiversity and colonisation of the wasted coffee tray leach.
Vilanova, Cristina; Iglesias, Alba; Porcar, Manuel
2015-11-23
Microbial communities are ubiquitous in both natural and artificial environments. However, microbial diversity is usually reduced under strong selection pressures, such as those present in habitats rich in recalcitrant or toxic compounds displaying antimicrobial properties. Caffeine is a natural alkaloid present in coffee, tea and soft drinks with well-known antibacterial properties. Here we present the first systematic analysis of coffee machine-associated bacteria. We sampled the coffee waste reservoir of ten different Nespresso machines and conducted a dynamic monitoring of the colonization process in a new machine. Our results reveal the existence of a varied bacterial community in all the machines sampled, and a rapid colonisation process of the coffee leach. The community developed from a pioneering pool of enterobacteria and other opportunistic taxa to a mature but still highly variable microbiome rich in coffee-adapted bacteria. The bacterial communities described here, for the first time, are potential drivers of biotechnologically relevant processes including decaffeination and bioremediation.
Infrared Spectroscopy for Rapid Characterization of Drill Core and Cutting Mineralogy
NASA Astrophysics Data System (ADS)
Calvin, W. M.; Kratt, C.; Kruse, F. A.
2009-12-01
Water geochemistry can vary with depth and location within a geothermal reservoir, owing to natural factors such as changing rock type, gas content, fluid source and temperature. The interaction of these variable fluids with the host rock will cause well known changes in alteration mineral assemblages that are commonly factored into the exploration of hydrothermal systems for economic metals, but are less utilized with regard to mapping borehole geology for geothermal energy production. Chemistry of geothermal fluids and rock alteration products can impact production factors such as pipeline corrosion and scaling and early studies explored the use of both silica and chlorites as geothermometers. Infrared spectroscopy is particularly good at identifying a wide variety of alteration minerals, especially in discrimination among clay minerals, with no sample preparation. The technique has been extensively used in the remote identification of materials, but is not commonly used on drill core or chips. We have performed several promising pilot studies that suggest the power of the technique to sample continuously and provide mineral logs akin to geophysical ones. We have surveyed a variety of samples, including drill chip boards, boxed core, and drill cuttings from envelopes, sample bottles and chip trays. This work has demonstrated that core and drill chips can be rapidly surveyed, acquiring spectra every few to tens of cm of section, or the vertical resolution of the chip tray (typically 10 feet). Depending on the sample type we can acquire spectral data over thousands of feet depth at high vertical resolution in a fraction of the time that is needed for traditional analytical methods such as XRD or TEM with better accuracy than traditional geologic drill or chip logging that uses visual inspection alone. We have successfully identified layered silicates such as illite, kaolinite, montmorillonite chlorite and prehnite, zeolites, opal, calcite, jarosite and iron oxides and hydroxides in geothermal drill samples. We are currently developing automated analysis techniques to convert this detailed spectral logging data into high-vertical-resolution mineral depth profiles that can be linked to lithology, stratigraphy, fracture zones and potential for geothermal production. Also in development are metrics that would link mapped mineralogy to known geothermometers such as Na-K, Mg depletion, discrimination among illite, montmorillonite, and beidellite, and kaolinite crystallinity. Identification of amorphous and crystalline silica components (chalcedony, crystobalite and quartz) can also constrain silica geothermometry. The degree of alteration and some mineral types have been shown to be a proxy for host rock permeability, natural circulation, and the potential for reservoir sealing. Analysis of alteration intensity is also under way. We will present a synthesis of results to date.
Space environmental effects on silvered Teflon thermal control surfaces
NASA Technical Reports Server (NTRS)
Hemminger, C. S.; Stuckey, W. K.; Uht, J. C.
1992-01-01
Cumulative space environmental effects on silver/fluorinated ethylene propylene (Ag/FEP) were a function of exposure orientation. Samples from nineteen silvered Teflon (Ag/FEP) thermal control surfaces recovered from the Long Duration Exposure Facility (LDEF) were analyzed to determine changes in this material as a function of position on the spacecraft. Although solar absorptance and infrared emittance of measured thermal blanket specimens are relatively unchanged from control specimen values, significant changes in surface morphology, composition, and chemistry were observed. We hypothesize that the FEP surfaces on the LDEF are degraded by UV radiation at all orientations, but that the damaged material has been removed by erosion from the blankets exposed to atomic oxygen flux and that contamination is masking the damage in some areas on the trays flanking the trailing edge.
ERIC Educational Resources Information Center
O'Malley, William
1969-01-01
Discussed are the exciting advantages and possibilities of using polystyrene trays found in meat packaging for printmaking. Among them are ease of use, low cost and quick availability of materials, beautiful textural effects. Procedures are explained for various age levels. (BF)