Sample records for samples blanks replicates

  1. Evaluation of Quality-Assurance/Quality-Control Data Collected by the U.S. Geological Survey from Wells and Springs between the Southern Boundary of the Idaho National Engineering and Environmental Laboratory and the Hagerman Area, Idaho, 1989 through 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, L.M.; Bartholomay, R.C.; Campbell, L.J.

    1998-10-01

    The U.S. Geological (USGS) and the Idaho Department of Water Resources, in cooperation with the U.S. Department of Energy, collected and analyzed water samples to monitor the water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering and Environmental Laboratory to the Hagerman area, Idaho. Concurrently, replicate samples and blank samples were collected and analyzed as part of the quality-assurance/quality-control program. Samples were analyzed from inorganic constituents, gross radioactivity and radionuclides, organic constituents, and stable isotopes. To evaluate the precision of field and laboratory methods, analytical results of the water-quality and replicate samplesmore » were compared statistically for equivalence on the basis of the precision associated with each result. Statistical comparisons of the data indicated that 95 percent of the results of the replicate pairs were equivalent. Blank-sample analytical results indicated th at the inorganic blank water and volatile organic compound blank water from the USGS National Water Quality Laboratory and the distilled water from the Idaho Department of Water Resources were suitable for blanks; blank water from other sources was not. Equipment-blank analytical results were evaluated to determine if a bias had been introduced and possible sources of bias. Most equipment blanks were analyzed for trace elements and volatile organic compounds; chloroform was found in one equipment blank. Two of the equipment blanks were prepared after collection and analyses of the water-quality samples to determine whether contamination had been introduced during the sampling process. Results of one blank indicated that a hose used to divert water away from pumps and electrical equipment had contaminated the samples with some volatile organic compounds. Results of the other equipment blank, from the apparatus used to filter dissolved organic carbon samples, indicated that the filtering apparatus did not affect water-quality samples.« less

  2. Interim results of quality-control sampling of surface water for the Upper Colorado River National Water-Quality Assessment Study Unit, water years 1995-96

    USGS Publications Warehouse

    Spahr, N.E.; Boulger, R.W.

    1997-01-01

    Quality-control samples provide part of the information needed to estimate the bias and variability that result from sample collection, processing, and analysis. Quality-control samples of surface water collected for the Upper Colorado River National Water-Quality Assessment study unit for water years 1995?96 are presented and analyzed in this report. The types of quality-control samples collected include pre-processing split replicates, concurrent replicates, sequential replicates, post-processing split replicates, and field blanks. Analysis of the pre-processing split replicates, concurrent replicates, sequential replicates, and post-processing split replicates is based on differences between analytical results of the environmental samples and analytical results of the quality-control samples. Results of these comparisons indicate that variability introduced by sample collection, processing, and handling is low and will not affect interpretation of the environmental data. The differences for most water-quality constituents is on the order of plus or minus 1 or 2 lowest rounding units. A lowest rounding unit is equivalent to the magnitude of the least significant figure reported for analytical results. The use of lowest rounding units avoids some of the difficulty in comparing differences between pairs of samples when concentrations span orders of magnitude and provides a measure of the practical significance of the effect of variability. Analysis of field-blank quality-control samples indicates that with the exception of chloride and silica, no systematic contamination of samples is apparent. Chloride contamination probably was the result of incomplete rinsing of the dilute cleaning solution from the outlet ports of the decaport sample splitter. Silica contamination seems to have been introduced by the blank water. Sampling and processing procedures for water year 1997 have been modified as a result of these analyses.

  3. Collection methods and quality assessment for Esche-richia coli, water quality, and microbial source tracking data within Tumacácori National Historical Park and the upper Santa Cruz River, Arizona, 2015-16

    USGS Publications Warehouse

    Paretti, Nicholas; Coes, Alissa L.; Kephart, Christopher M.; Mayo, Justine

    2018-03-05

    Tumacácori National Historical Park protects the culturally important Mission, San José de Tumacácori, while also managing a portion of the ecologically diverse riparian corridor of the Santa Cruz River. This report describes the methods and quality assurance procedures used in the collection of water samples for the analysis of Escherichia coli (E. coli), microbial source tracking markers, suspended sediment, water-quality parameters, turbidity, and the data collection for discharge and stage; the process for data review and approval is also described. Finally, this report provides a quantitative assessment of the quality of the E. coli, microbial source tracking, and suspended sediment data.The data-quality assessment revealed that bias attributed to field and laboratory contamination was minimal, with E. coli detections in only 3 out of 33 field blank samples analyzed. Concentrations in the field blanks were several orders of magnitude lower than environmental concentrations. The microbial source tracking (MST) field blank was below the detection limit for all MST markers analyzed. Laboratory blanks for E. coli at the USGS Arizona Water Science Center and laboratory blanks for MST markers at the USGS Ohio Water Microbiology Laboratory were all below the detection limit. Irreplicate data for E. coli and suspended sediment indicated that bias was not introduced to the data by combining samples collected using discrete sampling methods with samples collected using automatic sampling methods.The split and sequential E. coli replicate data showed consistent analytical variability and a single equation was developed to explain the variability of E. coli concentrations. An additional analysis of analytical variability for E. coli indicated analytical variability around 18 percent relative standard deviation and no trend was observed in the concentration during the processing and analysis of multiple split-replicates. Two replicate samples were collected for MST and individual markers were compared for a base flow and flood sample. For the markers found in common between the two types of samples, the relative standard deviation for the base flow sample was more than 3 times greater than the markers in the flood sample. Sequential suspended sediment replicates had a relative standard deviation of about 1.3 percent, indicating that environmental and analytical variability was minimal.A holding time review and laboratory study analysis supported the extended holding times required for this investigation. Most concentrations for flood and base-flow samples were within the theoretical variability specified in the most probable number approach suggesting that extended hold times did not overly influence the final concentrations reported.

  4. Quality-control results for ground-water and surface-water data, Sacramento River Basin, California, National Water-Quality Assessment, 1996-1998

    USGS Publications Warehouse

    Munday, Cathy; Domagalski, Joseph L.

    2003-01-01

    Evaluating the extent that bias and variability affect the interpretation of ground- and surface-water data is necessary to meet the objectives of the National Water-Quality Assessment (NAWQA) Program. Quality-control samples used to evaluate the bias and variability include annual equipment blanks, field blanks, field matrix spikes, surrogates, and replicates. This report contains quality-control results for the constituents critical to the ground- and surface-water components of the Sacramento River Basin study unit of the NAWQA Program. A critical constituent is one that was detected frequently (more than 50 percent of the time in blank samples), was detected at amounts exceeding water-quality standards or goals, or was important for the interpretation of water-quality data. Quality-control samples were collected along with ground- and surface-water samples during the high intensity phase (cycle 1) of the Sacramento River Basin NAWQA beginning early in 1996 and ending in 1998. Ground-water field blanks indicated contamination of varying levels of significance when compared with concentrations detected in environmental ground-water samples for ammonia, dissolved organic carbon, aluminum, and copper. Concentrations of aluminum in surface-water field blanks were significant when compared with environmental samples. Field blank samples collected for pesticide and volatile organic compound analyses revealed no contamination in either ground- or surface-water samples that would effect the interpretation of environmental data, with the possible exception of the volatile organic compound trichloromethane (chloroform) in ground water. Replicate samples for ground water and surface water indicate that variability resulting from sample collection, processing, and analysis was generally low. Some of the larger maximum relative percentage differences calculated for replicate samples occurred between samples having lowest absolute concentration differences and(or) values near the reporting limit. Surrogate recoveries for pesticides analyzed by gas chromatography/mass spectrometry (GC/MS), pesticides analyzed by high performance liquid chromatography (HPLC), and volatile organic compounds in ground- and surface-water samples were within the acceptable limits of 70 to 130 percent and median recovery values between 82 and 113 percent. The recovery percentages for surrogate compounds analyzed by HPLC had the highest standard deviation, 20 percent for ground-water samples and 16 percent for surface-water samples, and the lowest median values, 82 percent for ground-water samples and 91 percent for surface-water samples. Results were consistent with the recovery results described for the analytical methods. Field matrix spike recoveries for pesticide compounds analyzed using GC/MS in ground- and surface-water samples were comparable with published recovery data. Recoveries of carbofuran, a critical constituent in ground- and surface-water studies, and desethyl atrazine, a critical constituent in the ground-water study, could not be calculated because of problems with the analytical method. Recoveries of pesticides analyzed using HPLC in ground- and surface-water samples were generally low and comparable with published recovery data. Other methodological problems for HPLC analytes included nondetection of the spike compounds and estimated values of spike concentrations. Recovery of field matrix spikes for volatile organic compounds generally were within the acceptable range, 70 and 130 percent for both ground- and surface-water samples, and median recoveries from 62 to 127 percent. High or low recoveries could be related to errors in the field, such as double spiking or using spike solution past its expiration date, rather than problems during analysis. The methodological changes in the field spike protocol during the course of the Sacramento River Basin study, which included decreasing the amount of spike solu

  5. Evaluation of quality-control data collected by the U.S. Geological Survey for routine water-quality activities at the Idaho National Laboratory, Idaho, 1996–2001

    USGS Publications Warehouse

    Rattray, Gordon W.

    2012-01-01

    The U.S. Geological Survey, in cooperation with the U.S. Department of Energy, collects surface water and groundwater samples at and near the Idaho National Laboratory as part of a routine, site-wide, water-quality monitoring program. Quality-control samples are collected as part of the program to ensure and document the quality of environmental data. From 1996 to 2001, quality-control samples consisting of 204 replicates and 27 blanks were collected at sampling sites. Paired measurements from replicates were used to calculate variability (as reproducibility and reliability) from sample collection and analysis of radiochemical, chemical, and organic constituents. Measurements from field and equipment blanks were used to estimate the potential contamination bias of constituents. The reproducibility of measurements of constituents was calculated from paired measurements as the normalized absolute difference (NAD) or the relative standard deviation (RSD). The NADs and RSDs, as well as paired measurements with censored or estimated concentrations for which NADs and RSDs were not calculated, were compared to specified criteria to determine if the paired measurements had acceptable reproducibility. If the percentage of paired measurements with acceptable reproducibility for a constituent was greater than or equal to 90 percent, then the reproducibility for that constituent was considered acceptable. The percentage of paired measurements with acceptable reproducibility was greater than or equal to 90 percent for all constituents except orthophosphate (89 percent), zinc (80 percent), hexavalent chromium (53 percent), and total organic carbon (TOC; 38 percent). The low reproducibility for orthophosphate and zinc was attributed to calculation of RSDs for replicates with low concentrations of these constituents. The low reproducibility for hexavalent chromium and TOC was attributed to the inability to preserve hexavalent chromium in water samples and high variability with the analytical method for TOC. The reliability of measurements of constituents was estimated from pooled RSDs that were calculated for discrete concentration ranges for each constituent. Pooled RSDs of 15 to 33 percent were calculated for low concentrations of gross-beta radioactivity, strontium-90, ammonia, nitrite, orthophosphate, nickel, selenium, zinc, tetrachloroethene, and toluene. Lower pooled RSDs of 0 to 12 percent were calculated for all other concentration ranges of these constituents, and for all other constituents, except for one concentration range for gross-beta radioactivity, chloride, and nitrate + nitrite; two concentration ranges for hexavalent chromium; and TOC. Pooled RSDs for the 50 to 60 picocuries per liter concentration range of gross-beta radioactivity (reported as cesium-137) and the 10 to 60 milligrams per liter (mg/L) concentration range of nitrate + nitrite (reported as nitrogen [N]) were 17 percent. Chloride had a pooled RSD of 14 percent for the 20 to less than 60 mg/L concentration range. High pooled RSDs of 40 and 51 percent were calculated for two concentration ranges for hexavalent chromium and of 60 percent for TOC. Measurements from (1) field blanks were used to estimate the potential bias associated with environmental samples from sample collection and analysis, (2) equipment blanks were used to estimate the potential bias from cross contamination of samples collected from wells where portable sampling equipment was used, and (3) a source-solution blank was used to verify that the deionized water source-solution was free of the constituents of interest. If more than one measurement was available, the bias was estimated using order statistics and the binomial probability distribution. The source-solution blank had a detectable concentration of hexavalent chromium of 2 micrograms per liter. If this bias was from a source other than the source solution, then about 84 percent of the 117 hexavalent chromium measurements from environmental samples could have a bias of 10 percent or more. Of the 14 field blanks that were collected, only chloride (0.2 milligrams per liter) and ammonia (0.03 milligrams per liter as nitrogen), in one blank each, had detectable concentrations. With an estimated confidencelevel of 95 percent, at least 80 percent of the 1,987 chloride concentrations measured from all environmental samples had a potential bias of less than 8 percent. The ammonia bias, which may have occurred at the analytical laboratory, could produce a potential bias of 5-100 percent in eight potentially affected ammonia measurements. Of the 11 equipment blanks that were collected, chloride was detected in 4 of these blanks, sodium in 3 blanks, and sulfate and hexavalent chromium were each detected in 1 blank. The concentration of hexavalent chromium in the equipment blank was the same concentration as in the source-solution blank collected on the same day, which indicates that the hexavalent chromium in the equipment blank is probably from a source other than the portable sampling equipment, such as the sample bottles or the source-solution water itself. The potential bias for chloride, sodium, and sulfate measurements was estimated for environmental samples that were collected using portable sampling equipment. For chloride, it was estimated with 93 percent confidence that at least 80 percent of the measurements had a bias of less than 18 percent. For sodium and sulfate, it was estimated with 91 percent confidence that at least 70 percent of the measurements had a bias of less than 12 and 5 percent, respectively.

  6. Results of quality-control sampling of water, bed sediment, and tissue in the Western Lake Michigan Drainages study unit of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Fitzgerald, S.A.

    1997-01-01

    This report contains the quality control results of the Western Lake Michigan Drainages study unit of the National Water Quality Assessment Program. Quality control samples were collected in the same manner and contemporaneously with environmental samples during the first highintensity study phase in the unit (1992 through 1995) and amounted to approximately 15 percent of all samples collected. The accuracy and precision of hundreds of chemical analyses of surface and ground-water, bed sediment, and tissue was determined through the collection and analysis of field blanks, field replicates and splits, matrix spikes, and surrogates. Despite the several detections of analytes in the field blanks, the concentrations of most constituents in the environmental samples will likely be an order of magnitude or higher than those in the blanks. However, frequent detections, and high concentrations, of dissolved organic carbon (DOC) in several surface and ground-water blanks are probably significant with respect to commonly measured environmental concentrations, and the environmental data will have to be qualified accordingly. The precision of sampling of water on a percent basis, as determined from replicates and splits, was generally proportional to the concentration of the constituents, with constituents present in relatively high concentrations generally having less sampling variability than those with relatively low concentrations. In general, analytes with relatively high variability between replicates were present at concentrations near the reporting limit or were associated with relatively small absolute concentration differences, or both. Precision of replicates compared to that for splits in bed sediment samples was similar, thus eliminating sampling as a major source of variability in analyte concentrations. In the case the phthalates in bed sediment, contamination in either the field or laboratory could have caused the relatively large variability between replicate samples and between split samples.Variability of analyte concentrations in tissue samples was relatively low, being 29 percent or less for all constituents. Recoveries of most laboratory schedule 2001/2010 pesticide spike compounds in surfacewater samples were reasonably good. Low intrinsic method recovery resulted in relatively low recovery forp,p'-DDE, metribuzin, and propargite. In the case of propargite, decomposition with the environmental sample matrices was also indicated. Recoveries of two compounds, cyanazine and thiobencarb, might have been biased high due to interferences. The one laboratory schedule 2050/2051 field matrix pesticide spike indicated numerous operational problems with this method that biased recoveries either low or high. Recoveries of pesticides from both pesticide schedules in field spikes of ground-water samples generally were similar to those of field matrix spikes of surface- water samples. High maximum recoveries were noted for tebuthiuron, disulfoton, DCPA, and permethrin, which indicates the possible presence of interferents in the matrices for these compounds. Problems in the recoveries of pesticides on schedule 2050/2051 from ground-water samples generally were the same as those for surfacewater samples. Recoveries of VOCs in field matrix spikes were reasonable when consideration was given for the use of the micropipettor that delivered only about 80 percent on average of the nominal mass of spiked analytes. Finally, the recoveries of most surrogate compounds in surface and ground-water samples were reasonable. Problems in sample handling (for example, spillage) were likely not the cause of any of the low recoveries of spiked compounds.

  7. Chemical and radiochemical constituents in water from wells in the vicinity of the naval reactors facility, Idaho National Engineering and Environmental Laboratory, Idaho, 1997-98

    USGS Publications Warehouse

    Bartholomay, Roy C.; Knobel, LeRoy L.; Tucker, Betty J.; Twining, Brian V.

    2000-01-01

    The U.S. Geological Survey, in response to a request from the U.S. Department of Energy?s Phtsburgh Naval Reactors Ofilce, Idaho Branch Office, sampled water from 13 wells during 1997?98 as part of a long-term project to monitor water quality of the Snake River Plain aquifer in the vicinity of the Naval Reactors Facility, Idaho National Engineering and Environmental Laboratory, Idaho. Water samples were analyzed for naturally occurring constituents and man-made contaminants. A totalof91 samples were collected from the 13 monitoring wells. The routine samples contained detectable concentrations of total cations and dissolved anions, and nitrite plus nitrate as nitrogen. Most of the samples also had detectable concentrations of gross alpha- and gross beta-particle radioactivity and tritium. Fourteen qualityassurance samples also were collected and analyze~ seven were field-blank samples, and seven were replicate samples. Most of the field blank samples contained less than detectable concentrations of target constituents; however, some blank samples did contain detectable concentrations of calcium, magnesium, barium, copper, manganese, nickel, zinc, nitrite plus nitrate, total organic halogens, tritium, and selected volatile organic compounds.

  8. Evaluation of quality-control data collected by the U.S. Geological Survey for routine water-quality activities at the Idaho National Laboratory and vicinity, southeastern Idaho, 2002-08

    USGS Publications Warehouse

    Rattray, Gordon W.

    2014-01-01

    Quality-control (QC) samples were collected from 2002 through 2008 by the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, to ensure data robustness by documenting the variability and bias of water-quality data collected at surface-water and groundwater sites at and near the Idaho National Laboratory. QC samples consisted of 139 replicates and 22 blanks (approximately 11 percent of the number of environmental samples collected). Measurements from replicates were used to estimate variability (from field and laboratory procedures and sample heterogeneity), as reproducibility and reliability, of water-quality measurements of radiochemical, inorganic, and organic constituents. Measurements from blanks were used to estimate the potential contamination bias of selected radiochemical and inorganic constituents in water-quality samples, with an emphasis on identifying any cross contamination of samples collected with portable sampling equipment. The reproducibility of water-quality measurements was estimated with calculations of normalized absolute difference for radiochemical constituents and relative standard deviation (RSD) for inorganic and organic constituents. The reliability of water-quality measurements was estimated with pooled RSDs for all constituents. Reproducibility was acceptable for all constituents except dissolved aluminum and total organic carbon. Pooled RSDs were equal to or less than 14 percent for all constituents except for total organic carbon, which had pooled RSDs of 70 percent for the low concentration range and 4.4 percent for the high concentration range. Source-solution and equipment blanks were measured for concentrations of tritium, strontium-90, cesium-137, sodium, chloride, sulfate, and dissolved chromium. Field blanks were measured for the concentration of iodide. No detectable concentrations were measured from the blanks except for strontium-90 in one source solution and one equipment blank collected in September and October 2004, respectively. The detectable concentrations of strontium-90 in the blanks probably were from a small source of strontium-90 contamination or large measurement variability, or both. Order statistics and the binomial probability distribution were used to estimate the magnitude and extent of any potential contamination bias of tritium, strontium-90, cesium-137, sodium, chloride, sulfate, dissolved chromium, and iodide in water-quality samples. These statistical methods indicated that, with (1) 87 percent confidence, contamination bias of cesium-137 and sodium in 60 percent of water-quality samples was less than the minimum detectable concentration or reporting level; (2) 92‒94 percent confidence, contamination bias of tritium, strontium-90, chloride, sulfate, and dissolved chromium in 70 percent of water-quality samples was less than the minimum detectable concentration or reporting level; and (3) 75 percent confidence, contamination bias of iodide in 50 percent of water-quality samples was less than the reporting level for iodide. These results support the conclusion that contamination bias of water-quality samples from sample processing, storage, shipping, and analysis was insignificant and that cross-contamination of perched groundwater samples collected with bailers during 2002–08 was insignificant.

  9. 40 CFR Appendix B to Part 136 - Definition and Procedure for the Determination of the Method Detection Limit-Revision 1.11

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) GUIDELINES ESTABLISHING TEST PROCEDURES... to a wide variety of sample types ranging from reagent (blank) water containing analyte to wastewater... times the standard deviation of replicate instrumental measurements of the analyte in reagent water. (c...

  10. Review of Trace-Element Field-Blank Data Collected for the California Groundwater Ambient Monitoring and Assessment (GAMA) Program, May 2004-January 2008

    USGS Publications Warehouse

    Olsen, Lisa D.; Fram, Miranda S.; Belitz, Kenneth

    2010-01-01

    Trace-element quality-control samples (for example, source-solution blanks, field blanks, and field replicates) were collected as part of a statewide investigation of groundwater quality in California, known as the Priority Basins Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basins Project is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB) to assess and monitor the quality of groundwater resources used for drinking-water supply and to improve public knowledge of groundwater quality in California. Trace-element field blanks were collected to evaluate potential bias in the corresponding environmental data. Bias in the environmental data could result from contamination in the field during sample collection, from the groundwater coming into contact with contaminants on equipment surfaces or from other sources, or from processing, shipping, or analyzing the samples. Bias affects the interpretation of environmental data, particularly if any constituents are present solely as a result of extrinsic contamination that would have otherwise been absent from the groundwater that was sampled. Field blanks were collected, analyzed, and reviewed to identify and quantify extrinsic contamination bias. Data derived from source-solution blanks and laboratory quality-control samples also were considered in evaluating potential contamination bias. Eighty-six field-blank samples collected from May 2004 to January 2008 were analyzed for the concentrations of 25 trace elements. Results from these field blanks were used to interpret the data for the 816 samples of untreated groundwater collected over the same period. Constituents analyzed were aluminum (Al), antimony (Sb), arsenic (As), barium (Ba), beryllium (Be), boron (B), cadmium (Cd), chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), lead (Pb), lithium (Li), manganese (Mn), mercury (Hg), molybdenum (Mo), nickel (Ni), selenium (Se), silver (Ag), strontium (Sr), thallium (Tl), tungsten (W), uranium (U), vanadium (V), and zinc (Zn). The detection frequency and the 90th percentile concentration at greater than 90 percent confidence were determined from the field-blank data for each trace element, and these results were compared to each constituent's long-term method detection level (LT-MDL) to determine whether a study reporting level (SRL) was necessary to ensure that no more than 10 percent of the detections in groundwater samples could be attributed solely to contamination bias. Only two of the trace elements analyzed, Li and Se, had zero detections in the 86 field blanks. Ten other trace elements (Sb, As, Be, B, Cd, Co, Mo, Ag, Tl, and U) were detected in fewer than 5 percent of the field blanks. The field-blank results for these constituents did not necessitate establishing SRLs. Of the 13 constituents that were detected in more than 5 percent of the field blanks, six (Al, Ba, Cr, Mn, Hg, and V) had field-blank results that indicated a need for SRLs that were at or below the highest laboratory reporting levels (LRL) used during the sampling period; these SRLs were needed for concentrations between the LT-MDLs and LRLs. The other seven constituents with detection frequencies above 5 percent (Cu, Fe, Pb, Ni, Sr, W, and Zn) had field-blank results that necessitated SRLs greater than the highest LRLs used during the study period. SRLs for these seven constituents, each set at the 90th percentile of their concentrations in the field blanks, were at least an order of magnitude below the regulatory thresholds established for drinking water for health or aesthetic purposes; therefore, reporting values below the SRLs as less than or equal to (=) the measured value would not prevent the identification of values greater than the drinking-water thresholds. The SRLs and drinking-water thresholds, respectively, for these 7 trace elements are Cu (1.7 ?g/L and 1,300

  11. Quality of major ion and total dissolved solids data from groundwater sampled by the National Water-Quality Assessment Program, 1992–2010

    USGS Publications Warehouse

    Gross, Eliza L.; Lindsey, Bruce D.; Rupert, Michael G.

    2012-01-01

    Field blank samples help determine the frequency and magnitude of contamination bias, and replicate samples help determine the sampling variability (error) of measured analyte concentrations. Quality control data were evaluated for calcium, magnesium, sodium, potassium, chloride, sulfate, fluoride, silica, and total dissolved solids. A 99-percent upper confidence limit is calculated from field blanks to assess the potential for contamination bias. For magnesium, potassium, chloride, sulfate, and fluoride, potential contamination in more than 95 percent of environmental samples is less than or equal to the common maximum reporting level. Contamination bias has little effect on measured concentrations greater than 4.74 mg/L (milligrams per liter) for calcium, 14.98 mg/L for silica, 4.9 mg/L for sodium, and 120 mg/L for total dissolved solids. Estimates of sampling variability are calculated for high and low ranges of concentration for major ions and total dissolved solids. Examples showing the calculation of confidence intervals and how to determine whether measured differences between two water samples are significant are presented.

  12. Sampling for mercury at subnanogram per litre concentrations for load estimation in rivers

    USGS Publications Warehouse

    Colman, J.A.; Breault, R.F.

    2000-01-01

    Estimation of constituent loads in streams requires collection of stream samples that are representative of constituent concentrations, that is, composites of isokinetic multiple verticals collected along a stream transect. An all-Teflon isokinetic sampler (DH-81) cleaned in 75??C, 4 N HCl was tested using blank, split, and replicate samples to assess systematic and random sample contamination by mercury species. Mean mercury concentrations in field-equipment blanks were low: 0.135 ng??L-1 for total mercury (??Hg) and 0.0086 ng??L-1 for monomethyl mercury (MeHg). Mean square errors (MSE) for ??Hg and MeHg duplicate samples collected at eight sampling stations were not statistically different from MSE of samples split in the laboratory, which represent the analytical and splitting error. Low fieldblank concentrations and statistically equal duplicate- and split-sample MSE values indicate that no measurable contamination was occurring during sampling. Standard deviations associated with example mercury load estimations were four to five times larger, on a relative basis, than standard deviations calculated from duplicate samples, indicating that error of the load determination was primarily a function of the loading model used, not of sampling or analytical methods.

  13. Quality-control design for surface-water sampling in the National Water-Quality Network

    USGS Publications Warehouse

    Riskin, Melissa L.; Reutter, David C.; Martin, Jeffrey D.; Mueller, David K.

    2018-04-10

    The data-quality objectives for samples collected at surface-water sites in the National Water-Quality Network include estimating the extent to which contamination, matrix effects, and measurement variability affect interpretation of environmental conditions. Quality-control samples provide insight into how well the samples collected at surface-water sites represent the true environmental conditions. Quality-control samples used in this program include field blanks, replicates, and field matrix spikes. This report describes the design for collection of these quality-control samples and the data management needed to properly identify these samples in the U.S. Geological Survey’s national database.

  14. NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR PESTICIDE METABOLITES IN BLANK SAMPLES

    EPA Science Inventory

    The Pesticide Metabolites in Blank Samples data set contains the analytical results of measurements of up to 4 pesticide metabolites in 3 blank samples from 3 households. Measurements were made in blank samples of urine. Blank samples were used to assess the potential for sampl...

  15. NHEXAS PHASE I MARYLAND STUDY--QA ANALYTICAL RESULTS FOR PESTICIDE METABOLITES IN BLANKS

    EPA Science Inventory

    The Pesticide Metabolites in Blanks data set contains the analytical results of measurements of up to 4 pesticide metabolites in 14 blank samples from 13 households. Measurements were made in blank samples of urine. Blank samples were used to assess the potential for sample con...

  16. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--QA ANALYTICAL RESULTS FOR METALS IN BLANK SAMPLES

    EPA Science Inventory

    The Metals in Blank Samples data set contains the analytical results of measurements of up to 27 metals in 52 blank samples. Measurements were made in blank samples of dust, indoor air, food, water, and dermal wipe residue. Blank samples were used to assess the potential for sa...

  17. NHEXAS PHASE I REGION 5 STUDY--QA ANALYTICAL RESULTS FOR METALS IN BLANKS

    EPA Science Inventory

    This data set includes analytical results for measurements of metals in 205 blank samples and for particles in 64 blank samples. Measurements were made for up to 12 metals in blank samples of air, dust, soil, water, food and beverages, blood, hair, and urine. Blank samples were u...

  18. NHEXAS PHASE I MARYLAND STUDY--QA ANALYTICAL RESULTS FOR METALS IN BLANKS

    EPA Science Inventory

    The Metals in Blanks data set contains the analytical results of measurements of up to 11 metals in 115 blank samples from 58 households. Measurements were made in blank samples of indoor and outdoor air, drinking water, beverages, urine, and blood. Blank samples were used to a...

  19. NHEXAS PHASE I MARYLAND STUDY--QA ANALYTICAL RESULTS FOR PESTICIDES IN BLANKS

    EPA Science Inventory

    The Pesticides in Blanks data set contains the analytical results of measurements of up to 20 pesticides in 70 blank samples from 46 households. Measurements were made in blank samples of indoor air, dust, soil, drinking water, food, beverages, and blood serum. Blank samples we...

  20. Assessment of volatile organic compounds in surface water at West Branch Canal Creek, Aberdeen Proving Ground, Maryland, 1999

    USGS Publications Warehouse

    Olsen, Lisa D.; Spencer, Tracey A.

    2000-01-01

    The U.S. Geological Survey (USGS) collected 13 surface-water samples and 3 replicates from 5 sites in the West Branch Canal Creek area at Aberdeen Proving Ground from February through August 1999, as a part of an investigation of ground-water contamination and natural attenuation processes. The samples were analyzed for volatile organic compounds, including trichloroethylene, 1,1,2,2-tetrachloroethane, carbon tetrachloride, and chloroform, which are the four major contaminants that were detected in ground water in the Canal Creek area in earlier USGS studies. Field blanks were collected during the sampling period to assess sample bias. Field replicates were used to assess sample variability, which was expressed as relative percent difference. The mean variability of the surface-water replicate analyses was larger (35.4 percent) than the mean variability of ground-water replicate analyses (14.6 percent) determined for West Branch Canal Creek from 1995 through 1996. The higher variability in surface-water analyses is probably due to heterogeneities in the composition of the surface water rather than differences in sampling or analytical procedures. The most frequently detected volatile organic compound was 1,1,2,2- tetrachloroethane, which was detected in every sample and in two of the replicates. The surface-water contamination is likely the result of cross-media transfer of contaminants from the ground water and sediments along the West Branch Canal Creek. The full extent of surface-water contamination in West Branch Canal Creek and the locations of probable contaminant sources cannot be determined from this limited set of data. Tidal mixing, creek flow patterns, and potential effects of a drought that occurred during the sampling period also complicate the evaluation of surface-water contamination.

  1. NHEXAS PHASE I REGION 5 STUDY--QA ANALYTICAL RESULTS FOR VOCS IN BLANKS

    EPA Science Inventory

    This data set includes analytical results for measurements of VOCs in 88 blank samples. Measurements were made for up to 23 VOCs in blank samples of air, water, and blood. Blank samples were used to assess the potential for sample contamination during collection, storage, shipmen...

  2. NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR PESTICIDES IN BLANK SAMPLES

    EPA Science Inventory

    The Pesticides in Blank Samples data set contains the analytical results of measurements of up to 4 pesticides in 43 blank samples from 29 households. Measurements were made in blank samples of dust, indoor and outdoor air, food and beverages, blood, urine, and dermal wipe resid...

  3. NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR METALS IN BLANK SAMPLES

    EPA Science Inventory

    The Metals in Blank Samples data set contains the analytical results of measurements of up to 27 metals in 82 blank samples from 26 households. Measurements were made in blank samples of dust, indoor and outdoor air, personal air, food, beverages, blood, urine, and dermal wipe r...

  4. Quality of volatile organic compound data from groundwater and surface water for the National Water-Quality Assessment Program, October 1996–December 2008

    USGS Publications Warehouse

    Bender, David A.; Zogorski, John S.; Mueller, David K.; Rose, Donna L.; Martin, Jeffrey D.; Brenner, Cassandra K.

    2011-01-01

    This report describes the quality of volatile organic compound (VOC) data collected from October 1996 to December 2008 from groundwater and surface-water sites for the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) Program. The VOC data described were collected for three NAWQA site types: (1) domestic and public-supply wells, (2) monitoring wells, and (3) surface-water sites. Contamination bias, based on the 90-percent upper confidence limit (UCL) for the 90th percentile of concentrations in field blanks, was determined for VOC samples from the three site types. A way to express this bias is that there is 90-percent confidence that this amount of contamination would be exceeded in no more than 10 percent of all samples (including environmental samples) that were collected, processed, shipped, and analyzed in the same manner as the blank samples. This report also describes how important native water rinsing may be in decreasing carryover contamination, which could be affecting field blanks. The VOCs can be classified into four contamination categories on the basis of the 90-percent upper confidence limit (90-percent UCL) concentration distribution in field blanks. Contamination category 1 includes compounds that were not detected in any field blanks. Contamination category 2 includes VOCs that have a 90-percent UCL concentration distribution in field blanks that is about an order of magnitude lower than the concentration distribution of the environmental samples. Contamination category 3 includes VOCs that have a 90-percent UCL concentration distribution in field blanks that is within an order of magnitude of the distribution in environmental samples. Contamination category 4 includes VOCs that have a 90-percent UCL concentration distribution in field blanks that is at least an order of magnitude larger than the concentration distribution of the environmental samples. Fifty-four of the 87 VOCs analyzed in samples from domestic and public-supply wells were not detected in field blanks (contamination category 1), and 33 VOC were detected in field blanks. Ten of the 33 VOCs had a 90-percent UCL concentration distribution in field blanks that was at least an order of magnitude lower than the concentration distribution in environmental samples (contamination category 2). These 10 VOCs may have had some contamination bias associated with the environmental samples, but the potential contamination bias was negligible in comparison to the environmental data; therefore, the field blanks were assumed to be representative of the sources of contamination bias affecting the environmental samples for these 10 VOCs. Seven VOCs had a 90-percent UCL concentration distribution of the field blanks that was within an order of magnitude of the concentration distribution of the environmental samples (contamination category 3). Sixteen VOCs had a 90-percent UCL concentration distribution in the field blanks that was at least an order of magnitude greater than the concentration distribution of the environmental samples (contamination category 4). Field blanks for these 16 VOCs appear to be nonrepresentative of the sources of contamination bias affecting the environmental samples because of the larger concentration distributions (and sometimes higher frequency of detection) in field blanks than in environmental samples. Forty-three of the 87 VOCs analyzed in samples from monitoring wells were not detected in field blanks (contamination category 1), and 44 VOCs were detected in field blanks. Eight of the 44 VOCs had a 90-percent UCL concentration distribution in field blanks that was at least an order of magnitude lower than concentrations in environmental samples (contamination category 2). These eight VOCs may have had some contamination bias associated with the environmental samples, but the potential contamination bias was negligible in comparison to the environmental data; therefore, the field blanks were assumed to be representative. Seven VOCs had a 90-percent UCL concentration distribution in field blanks that was of the same order of magnitude as the concentration distribution of the environmental samples (contamination category 3). Twenty-nine VOCs had a 90-percent UCL concentration distribution in the field blanks that was an order of magnitude greater than the distribution of the environmental samples (contamination category 4). Field blanks for these 29 VOCs appear to be nonrepresentative of the sources of contamination bias to the environmental samples. Fifty-four of the 87 VOCs analyzed in surface-water samples were not detected in field blanks (category 1), and 33 VOC were detected in field blanks. Sixteen of the 33 VOCs had a 90-percent UCL concentration distribution in field blanks that was at least an order of magnitude lower than the concentration distribution in environmental samples (contamination category 2). These 16 VOCs may have had some contamination bias associated with the environmental samples, but the potential contamination bias was negligible in comparison to the environmental data; therefore, the field blanks were assumed to be representative. Ten VOCs had a 90-percent UCL concentration distribution in field blanks that was similar to the concentration distribution of environmental samples (contamination category 3). Seven VOCs had a 90-percent UCL concentration distribution in the field blanks that was greater than the concentration distribution in environmental samples (contamination category 4). Field-blank samples for these seven VOCs appear to be nonrepresentative of the sources of contamination bias to the environmental samples. The relation between the detection of a compound in field blanks and the detection in subsequent environmental samples appears to be minimal. The median minimum percent effectiveness of native water rinsing is about 79 percent for the 19 VOCs detected in more than 5 percent of field blanks from all three site types. The minimum percent effectiveness of native water rinsing (10 percent) was for toluene in surface-water samples, likely because of the large detection frequency of toluene in surface-water samples (about 79 percent) and in the associated field-blank samples (46.5 percent). The VOCs that were not detected in field blanks (contamination category 1) from the three site types can be considered free of contamination bias, and various interpretations for environmental samples, such as VOC detection frequency at multiple assessment levels and comparisons of concentrations to benchmarks, are not limited for these VOCs. A censoring level for making comparisons at different assessment levels among environmental samples could be applied to concentrations of 9 VOCs in samples from domestic and public-supply wells, 16 VOCs in samples from monitoring wells, and 9 VOCs in surface-water samples to account for potential low-level contamination bias associated with these selected VOCs. Bracketing the potential contamination by comparing the detection and concentration statistics with no censoring applied to the potential for contamination bias on the basis of the 90-percent UCL for the 90th-percentile concentrations in field blanks may be useful when comparisons to benchmarks are done in a study. The VOCs that were not detected in field blanks (contamination category 1) from the three site types can be considered free of contamination bias, and various interpretations for environmental samples, such as VOC detection frequency at multiple assessment levels and comparisons of concentrations to benchmarks, are not limited for these VOCs. A censoring level for making comparisons at different assessment levels among environmental samples could be applied to concentrations of 9 VOCs in samples from domestic and public-supply wells, 16 VOCs in samples from monitoring wells, and 9 VOCs in surface-water samples to account for potential low-level contamination bias associated with these selected VOCs. Bracketing the potential contamination by comparing the detection and concentration statistics with no censoring applied to the potential for contamination bias on the basis of the 90-percent UCL for the 90th-percentile concentrations in field blanks may be useful when comparisons to benchmarks are done in a study.

  5. Evaluation of volatile organic compound (VOC) blank data and application of study reporting levels to groundwater data collected for the California GAMA Priority Basin Project, May 2004 through September 2010

    USGS Publications Warehouse

    Fram, Miranda S.; Olsen, Lisa D.; Belitz, Kenneth

    2012-01-01

    Volatile organic compounds (VOCs) were analyzed in quality-control samples collected for the California Groundwater Ambient Monitoring and Assessment (GAMA) Program Priority Basin Project. From May 2004 through September 2010, a total of 2,026 groundwater samples, 211 field blanks, and 109 source-solution blanks were collected and analyzed for concentrations of 85 VOCs. Results from analyses of these field and source-solution blanks and of 2,411 laboratory instrument blanks during the same time period were used to assess the quality of data for the 2,026 groundwater samples. Eighteen VOCs were detected in field blanks or source-solution blanks: acetone, benzene, bromodichloromethane, 2-butanone, carbon disulfide, chloroform, 1,1-dichloroethene, dichloromethane, ethylbenzene, tetrachloroethene, styrene, tetrahydrofuran, toluene, trichloroethene, trichlorofluoromethane, 1,2,4-trimethylbenzene, m- and p-xylenes, and o-xylene. The objective of the evaluation of the VOC-blank data was to determine if study reporting levels (SRLs) were needed for any of the VOCs detected in blanks to ensure the quality of the data from groundwater samples. An SRL is equivalent to a raised reporting level that is used in place of the reporting level used by the analyzing laboratory [long‑term method detection level (LT-MDL) or laboratory reporting level (LRL)] to reduce the probability of reporting false-positive detections. Evaluation of VOC-blank data was done in three stages: (1) identification of a set of representative quality‑control field blanks (QCFBs) to be used for calculation of SRLs and identification of VOCs amenable to the SRL approach, (2) evaluation of potential sources of contamination to blanks and groundwater samples by VOCs detected in field blanks, and (3) selection of appropriate SRLs from among four potential SRLs for VOCs detected in field blanks and application of those SRLs to the groundwater data. An important conclusion from this study is that to ensure the quality of the data from groundwater samples, it was necessary to apply different methods of determining SRLs from field blank data to different VOCs, rather than use the same method for all VOCs. Four potential SRL values were defined by using three approaches: two values were defined by using a binomial probability method based on one-sided, nonparametric upper confidence limits, one was defined as equal to the maximum concentration detected in the field blanks, and one was defined as equal to the maximum laboratory method detection level used during the period when samples were collected for the project. The differences in detection frequencies and concentrations among different types of blanks (laboratory instrument blanks, source-solution blanks, and field blanks collected with three different sampling equipment configurations) and groundwater samples were used to infer the sources and mechanisms of contamination for each VOC detection in field blanks. Other chemical data for the groundwater samples (oxidation-reduction state, co-occurrence of VOCs, groundwater age) and ancillary information about the well sites (land use, presence of known sources of contamination) were used to evaluate whether the patterns of detections of VOCs in groundwater samples before and after application of potential SRLs were plausible. On this basis, the appropriate SRL was selected for each VOC that was determined to require an SRL. The SRLs for ethylbenzene [0.06 microgram per liter (μg/L)], m- and p-xylenes (0.33 μg/L), o-xylene (0.12 μg/L), toluene (0.69 μg/L), and 1,2,4-trimethylbenzene (0.56 μg/L) corresponded to the highest concentrations detected in the QCFBs and were selected because they resulted in the most censoring of groundwater data. Comparisons of hydrocarbon ratios in groundwater samples and blanks and comparisons between detection frequencies of the five hydrocarbons in groundwater samples and different types of blanks suggested three dominant sources of contamination that affected groundwater samples and blanks: (1) ethylbenzene, m- and p-xylenes, o-xylene, and toluene from fuel or exhaust components sorbed onto sampling lines, (2) toluene from vials and the source blank water, and (3) 1,2,4-trimethylbenzene from materials used for collection of samples for radon-222 analysis.

  6. Can Coloring Mandalas Reduce Anxiety? A Replication Study

    ERIC Educational Resources Information Center

    van der Vennet, Renee; Serice, Susan

    2012-01-01

    This experimental study replicated Curry and Kasser's (2005) research that tested whether coloring a mandala would reduce anxiety. After inducing an anxious mood via a writing activity, participants were randomly assigned to three groups that colored either on a mandala design, on a plaid design, or on a blank paper. Anxiety level was measured…

  7. Groundwater-quality data from the eastern Snake River Plain Aquifer, Jerome and Gooding Counties, south-central Idaho, 2017

    USGS Publications Warehouse

    Skinner, Kenneth D.

    2018-05-11

    Groundwater-quality samples and water-level data were collected from 36 wells in the Jerome/Gooding County area of the eastern Snake River Plain aquifer during June 2017. The wells included 30 wells sampled for the U.S. Geological Survey’s National Water-Quality Assessment project, plus an additional 6 wells were selected to increase spatial distribution. The data provide water managers with the ability for an improved understanding of groundwater quality and flow directions in the area. Groundwater-quality samples were analyzed for nutrients, major ions, trace elements, and stable isotopes of water. Quality-assurance and quality-control measures consisted of multiple blank samples and a sequential replicate sample. All data are available online at the USGS National Water Information System.

  8. A graphical method for determining the dry-depositional component of aerosol samples and their field blanks

    NASA Astrophysics Data System (ADS)

    Huang, Suilou; Rahn, Kenneth A.; Arimoto, Richard

    During the Atmosphere/Ocean Chemistry Experiment (AEROCE), field blanks of certain elements in aerosol samples occasionally increased abruptly, always during periods of unusually high atmospheric concentrations. We hypothesized that the anomalous blanks were created by coarse aerosol entering the sampling shelters and depositing onto the blank filters. If so, samples taken nearby should have been similarly affected. To test this hypothesis, we developed a simple graphical method in which elemental masses in field blanks are plotted against elemental masses in pumped samples, and zones of proportionality between the two are sought. Data from Bermuda and Mace Head (coastal western Ireland) confirmed that depositional zones did indeed appear, but only for coarse-particle elements and only under certain conditions. Actual increases of crustal and pollution-derived elements agreed well with values predicted from settling velocities and sampling rates: blanks increased up to an order of magnitude or more but samples by less than 1%. Marine elements behaved like crustal elements in most samples but occasionally were much more enriched: blanks increased up to 30-fold and samples up to about 3%. It thus appears that when coarse-particle elements are present in high concentrations, their field blanks and samples may be measurably affected by dry deposition. Depending on the elements of interest, this dry deposition may have to be measured and the concentrations corrected.

  9. Microbial source tracking markers at three inland recreational lakes in Ohio, 2011

    USGS Publications Warehouse

    Francy, Donna S.; Stelzer, Erin A.

    2012-01-01

    During the 2011 recreational season, samples were collected for E. coli and microbial source tracking (MST) marker concentrations to begin to understand potential sources of fecal contamination at three inland recreational lakes in Ohio - Buckeye, Atwood, and Tappan Lakes. The results from 32 regular samples, 4 field blanks, and 7 field replicates collected at 5 sites are presented in this report. At the three lakes, the ruminant-associated marker was found most often (57-73 percent of samples) but at estimated quantities, followed by the dog-associated marker (30-43 percent of samples). The human-associated marker was found in 14 and 50 percent of samples from Atwood and Tappan Lakes, respectively, but was not found in any samples from the two Buckeye Lake sites. The gull-associated marker was detected in only two samples, both from Tappan Lake.

  10. Determination of the anionic surfactant di(ethylhexyl) sodium sulfosuccinate in water samples collected from Gulf of Mexico coastal waters before and after landfall of oil from the Deepwater Horizon oil spill, May to October, 2010

    USGS Publications Warehouse

    Gray, James L.; Kanagy, Leslie K.; Furlong, Edward T.; McCoy, Jeff W.; Kanagy, Chris J.

    2011-01-01

    On April 22, 2010, the explosion on and subsequent sinking of the Deepwater Horizon oil drilling platform resulted in the release of crude oil into the Gulf of Mexico. At least 4.4 million barrels had been released into the Gulf of Mexico through July 15, 2010, 10 to 29 percent of which was chemically dispersed, primarily using two dispersant formulations. Initially, the dispersant Corexit 9527 was used, and when existing stocks of that formulation were exhausted, Corexit 9500 was used. Over 1.8 million gallons of the two dispersants were applied in the first 3 months after the spill. This report presents the development of an analytical method to analyze one of the primary surfactant components of both Corexit formulations, di(ethylhexyl) sodium sulfosuccinate (DOSS), the preliminary results, and the associated quality assurance/quality control (QA/QC) from samples collected from various points on the Gulf Coast between Texas and Florida. Seventy water samples and 8 field QC samples were collected before the predicted landfall of oil (pre-landfall) on the Gulf Coast, and 51 water samples and 10 field QC samples after the oil made landfall (post-landfall). Samples were collected in Teflon(Registered) bottles and stored at -20(degrees)C until analysis. Extraction of whole-water samples used sorption onto a polytetrafluoroethylene (PTFE) filter to isolate DOSS, with subsequent 50 percent methanol/water elution of the combined dissolved and particulate DOSS fractions. High-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) was used to identify and quantify DOSS by the isotope dilution method, using a custom-synthesized 13C4-DOSS labeled standard. Because of the ubiquitous presence of DOSS in laboratory reagent water, a chromatographic column was installed in the LC/MS/MS between the system pumps and the sample injector that separated this ambient background DOSS contamination from the sample DOSS, minimizing one source of blank contamination. Laboratory and field QA/QC for pre-landfall samples included laboratory reagent spike and blank samples, a total of 34 replicate analyses for the 78 environmental and field blank samples, and 11 randomly chosen laboratory matrix spike samples. Laboratory and field QA/QC for post-landfall samples included laboratory reagent spike and blank samples, a laboratory 'in-bottle' duplicate for each sample, and analysis of 24 randomly chosen laboratory matrix spike samples. Average DOSS recovery of 89(+/-)9.5 percent in all native (non-13C4-DOSS ) spikes was observed, with a mean relative percent difference between sample duplicates of 36 percent. The reporting limit for this analysis was 0.25 micrograms per liter due to blank limitations; DOSS was not detected in any samples collected in October (after oil landfall at certain study sites) above that concentration. It was detected prior to oil landfall above 0.25 micrograms per liter in 3 samples, but none exceeded the Environmental Protection Agency aquatic life criteria of 40 micrograms per liter.

  11. Hierarchical cluster analysis of technical replicates to identify interferents in untargeted mass spectrometry metabolomics.

    PubMed

    Caesar, Lindsay K; Kvalheim, Olav M; Cech, Nadja B

    2018-08-27

    Mass spectral data sets often contain experimental artefacts, and data filtering prior to statistical analysis is crucial to extract reliable information. This is particularly true in untargeted metabolomics analyses, where the analyte(s) of interest are not known a priori. It is often assumed that chemical interferents (i.e. solvent contaminants such as plasticizers) are consistent across samples, and can be removed by background subtraction from blank injections. On the contrary, it is shown here that chemical contaminants may vary in abundance across each injection, potentially leading to their misidentification as relevant sample components. With this metabolomics study, we demonstrate the effectiveness of hierarchical cluster analysis (HCA) of replicate injections (technical replicates) as a methodology to identify chemical interferents and reduce their contaminating contribution to metabolomics models. Pools of metabolites with varying complexity were prepared from the botanical Angelica keiskei Koidzumi and spiked with known metabolites. Each set of pools was analyzed in triplicate and at multiple concentrations using ultraperformance liquid chromatography coupled to mass spectrometry (UPLC-MS). Before filtering, HCA failed to cluster replicates in the data sets. To identify contaminant peaks, we developed a filtering process that evaluated the relative peak area variance of each variable within triplicate injections. These interferent peaks were found across all samples, but did not show consistent peak area from injection to injection, even when evaluating the same chemical sample. This filtering process identified 128 ions that appear to originate from the UPLC-MS system. Data sets collected for a high number of pools with comparatively simple chemical composition were highly influenced by these chemical interferents, as were samples that were analyzed at a low concentration. When chemical interferent masses were removed, technical replicates clustered in all data sets. This work highlights the importance of technical replication in mass spectrometry-based studies, and presents a new application of HCA as a tool for evaluating the effectiveness of data filtering prior to statistical analysis. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Design and evaluation of a field study on the contamination of selected volatile organic compounds and wastewater-indicator compounds in blanks and groundwater samples

    USGS Publications Warehouse

    Thiros, Susan A.; Bender, David A.; Mueller, David K.; Rose, Donna L.; Olsen, Lisa D.; Martin, Jeffrey D.; Bernard, Bruce; Zogorski, John S.

    2011-01-01

    The Field Contamination Study (FCS) was designed to determine the field processes that tend to result in clean field blanks and to identify potential sources of contamination to blanks collected in the field from selected volatile organic compounds (VOCs) and wastewater-indicator compounds (WICs). The VOCs and WICs analyzed in the FCS were detected in blanks collected by the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) Program during 1996–2008 and 2002–08, respectively. To minimize the number of variables, the study required ordering of supplies just before sampling, storage of supplies and equipment in clean areas, and use of adequate amounts of purge-and-trap volatile-grade methanol and volatile pesticide-grade blank water (VPBW) to clean sampling equipment and to collect field blanks.Blanks and groundwater samples were collected during 2008–09 at 16 sites, which were a mix of water-supply and monitoring wells, located in 9 States. Five different sample types were collected for the FCS at each site: (1) a source-solution blank collected at the USGS National Water Quality Laboratory (NWQL) using laboratory-purged VPBW, (2) source-solution blanks collected in the field using laboratory-purged VPBW, (3) source-solution blanks collected in the field using field-purged VPBW, (4) a field blank collected using field-purged VPBW, and (5) a groundwater sample collected from a well. The source-solution blank and field-blank analyses were used to identify, quantify, and document extrinsic contamination and to help determine the sources and causes of data-quality problems that can affect groundwater samples.Concentrations of compounds detected in FCS analyses were quantified and results were stored in the USGS National Water Information System database after meeting rigorous identification and quantification criteria. The study also utilized information provided by laboratory analysts about evidence indicating the presence of selected compounds, using less rigorous identification criteria than is required for reporting data to the National Water Information System database. For the FCS, these data are considered adequate to indicate "evidence of presence," and were used only for diagnostic purposes. Evidence of VOCs and WICs at low concentrations near or less than the long-term method detection level can indicate a contamination problem that could affect future datasets if method detection levels were ever to be lowered.

  13. Water- and air-quality monitoring of the Sweetwater Reservoir Watershed, San Diego County, California - Phase One results, continued, 2001-2003

    USGS Publications Warehouse

    Mendez, Gregory O.; Foreman, William T.; Morita, Andrew; Majewski, Michael S.

    2008-01-01

    In 1998, the U.S. Geological Survey, in cooperation with the Sweetwater Authority, began a study to monitor water, air, and sediment at the Sweetwater and Loveland Reservoirs in San Diego County, California. The study includes regular sampling of water and air at Sweetwater Reservoir for chemical constituents, including volatile organic compounds (VOC), polynuclear aromatic hydrocarbons (PAH), pesticides, and major and trace elements. The purpose of this study is to monitor changes in contaminant composition and concentration during the construction and operation of State Route 125. To accomplish this, the study was divided into two phases. Phase One sampling (water years 1998–2004) determined baseline conditions for the detection frequency and the concentrations of target compounds in air and water. Phase Two sampling (starting water year 2005) continues at selected monitoring sites during and after construction of State Route 125 to assess the chemical impact this roadway alignment may have on water quality in the reservoir. Water samples were collected for VOCs and pesticides at Loveland Reservoir during Phase One and will be collected during Phase Two for comparison purposes. Air samples collected to monitor changes in VOCs, PAHs, and pesticides were analyzed by adapting methods used to analyze water samples. Bed-sediment samples have been and will be collected three times during the study; at the beginning of Phase One, at the start of Phase Two, and near the end of the study. In addition to the ongoing data collection, several special studies were initiated to assess the occurrence of specific chemicals of concern, such as trace metals, anthropogenic indicator compounds, and pharmaceuticals. This report describes the study design, and the sampling and analytical methods, and presents data from water and air samples collected during the fourth and fifth years of Phase One of the study (October 2001 to September 2003). Data collected during the first three years has been previously published. Three types of quality-control samples were used in this study: blanks, spikes, and replicates. Blanks and spikes are used to estimate result bias, and replicates are used to estimate result variability. Additionally, surrogate compounds were added at the laboratory to samples of VOCs, PAHs, pesticides, anthropogenic indicator compounds, and pharmaceuticals to monitor sample-specific performance of the analytical method.

  14. Blank and sample handling troubleshooting in ultratrace analysis of alkylphenols and bisphenol A by liquid chromatography tandem mass spectrometry.

    PubMed

    Salgueiro-González, N; Concha-Graña, E; Turnes-Carou, I; Muniategui-Lorenzo, S; López-Mahía, P; Prada-Rodríguez, D

    2012-11-15

    Blank contamination is a notorious problem in the ultratrace analysis of alkylphenols and bisphenol A. The achievement of low detection limits is complicated due to the high background signals. Furthermore, overestimations and underestimations in the analytical results can occur when blank levels are not stable. Thus, a review of sources of blank contamination in this type of analysis was carried out. Several sources of contamination were identified and useful guidelines are proposed for the determination of these compounds in water samples by liquid chromatography coupled with mass spectrometry. The system contamination was maintained below 0.09 ng (reagent blank) for all compounds and below 0.003 μg L(-1) (procedure blank). The main improvement was obtained by using LC-MS grade solvent in the mobile phase and PTFE syringe filters for the filtration of the sample extracts. Sample handling aspects such as filtration and storage of the water samples were also considered. The filtration of the samples should be avoided because both contamination and adsorption problems were observed when different kinds of filters were assayed. The refrigerated storage of water samples should be limited to 5 days (without addition of methanol) or 8 days (with 5% methanol). Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Measurement uncertainty of ester number, acid number and patchouli alcohol of patchouli oil produced in Yogyakarta

    NASA Astrophysics Data System (ADS)

    Istiningrum, Reni Banowati; Saepuloh, Azis; Jannah, Wirdatul; Aji, Didit Waskito

    2017-03-01

    Yogyakarta is one of patchouli oil distillation center in Indonesia. The quality of patchouli oil greatly affect its market price. Therefore, testing quality of patchouli oil parameters is an important concern, one through determination of the measurement uncertainty. This study will determine the measurement uncertainty of ester number, acid number and content of patchouli alcohol through a bottom up approach. Source contributor to measurement uncertainty of ester number is a mass of the sample, a blank and sample titration volume, the molar mass of KOH, HCl normality, and replication. While the source contributor of the measurement uncertainty of acid number is the mass of the sample, the sample titration volume, the relative mass and normality of KOH, and repetition. Determination of patchouli alcohol by Gas Chromatography considers the sources of measurement uncertainty only from repeatability because reference materials are not available.

  16. Development of a Dispersive Liquid-Liquid Microextraction Method Combined with UV-Visible Spectrophotometry for Determination of Trace Aluminum(III) in Water, Wastewater, Food, Biological, and Pharmaceutical Samples.

    PubMed

    Birgani, Nasrin Taghipour; Elhami, Shahla

    2017-01-01

    A simple and sensitive method was proposed for the preconcentration of trace levels of Al(III) prior to its determination by spectrophotometry, based on dispersive liquid-liquid microextraction. The complexation of the Al(III) was performed by chelation with Eriochrome Cyanine R (ECR). In this method, cetyltrimethyl ammonium bromide (CTAB) as a dispersant was dissolved in chloroform as an extractant solvent, and then the solution was rapidly injected by a syringe into the samples containing Al(III), which had already been complexed by ECR at optimized pH. Various parameters were studied and optimized for a 10 mL sample volume. Under the optimum conditions, the LOD (3 times the SD of 10 replicate readings of the reagent blank) and the dynamic range of the calibration obtained were 0.2 ng mL-1 (7 nM) and 1.0-80.0 ng mL-1, respectively. The RSDs for eight replicate determinations of 10 and 60 ng mL-1 of Al(III) were 3.3 and 1.8%, respectively. This strategy was successfully applied to determine the Al concentration in water, wastewater, yogurt, apple, carrot, celery, bread, potato, urine, and Al-Mg syrup samples.

  17. Evaluation of nutrient quality-assurance data for Alexanders and Mount Rock Spring basins, Cumberland County, Pennsylvania

    USGS Publications Warehouse

    Witt, E. C.; Hippe, D.J.; Giovannitti, R.M.

    1992-01-01

    A total of 304 nutrient samples were collected from May 1990 through September 1991 to determine concentrations and loads of nutrients in water discharged from two spring basins in Cumberland County, Pa. Fifty-four percent of these nutrient samples were for the evaluation of (1) laboratory consistency, (2) container and preservative cleanliness, (3) maintenance of analyte representativeness as affected by three different preservation methods, and (4) comparison of analyte results with the "Most Probable Value" for Standard Reference Water Samples. Results of 37 duplicate analyses indicate that the Pennsylvania Department of Environmental Resources, Bureau of Laboratories (principal laboratory) remained within its ±10 percent goal for all but one analyte. Results of the blank analysis show that the sampling containers did not compromise the water quality. However, mercuric-chloride-preservation blanks apparently contained measurable ammonium in four of five samples and ammonium plus organic nitrogen in two of five samples. Interlaboratory results indicate substantial differences in the determination of nitrate and ammonium plus organic nitrogen between the principal laboratory and the U.S. Geological Survey National Water-Quality Laboratory. In comparison with the U.S. Environmental Protection Agency Quality-Control Samples, the principal laboratory was sufficiently accurate in its determination of nutrient anafytes. Analysis of replicate samples indicated that sulfuric-acid preservative best maintained the representativeness of the anafytes nitrate and ammonium plus organic nitrogen, whereas, mercuric chloride best maintained the representativeness of orthophosphate. Comparison of nutrient analyte determinations with the Most Probable Value for each preservation method shows that two of five analytes with no chemical preservative compare well, three of five with mercuric-chloride preservative compare well, and three of five with sulfuricacid preservative compare well.

  18. Improved confidence intervals when the sample is counted an integer times longer than the blank.

    PubMed

    Potter, William Edward; Strzelczyk, Jadwiga Jodi

    2011-05-01

    Past computer solutions for confidence intervals in paired counting are extended to the case where the ratio of the sample count time to the blank count time is taken to be an integer, IRR. Previously, confidence intervals have been named Neyman-Pearson confidence intervals; more correctly they should have been named Neyman confidence intervals or simply confidence intervals. The technique utilized mimics a technique used by Pearson and Hartley to tabulate confidence intervals for the expected value of the discrete Poisson and Binomial distributions. The blank count and the contribution of the sample to the gross count are assumed to be Poisson distributed. The expected value of the blank count, in the sample count time, is assumed known. The net count, OC, is taken to be the gross count minus the product of IRR with the blank count. The probability density function (PDF) for the net count can be determined in a straightforward manner.

  19. Volatile organic compound data from three karst springs in middle Tennessee, February 2000 to May 2001

    USGS Publications Warehouse

    Williams, Shannon D.; Farmer, James

    2003-01-01

    The U.S. Geological Survey (USGS), in cooperation with the Tennessee Department of Environment and Conservation, Division of Superfund, collected discharge, rainfall, continuous water-quality (temperature, dissolved oxygen, specific conductance, and pH), and volatile organic compound (VOC) data from three karst springs in Middle Tennessee from February 2000 to May 2001. Continuous monitoring data indicated that each spring responds differently to storms. Water quality and discharge at Wilson Spring, which is located in the Central Basin karst region of Tennessee, changed rapidly after rainfall. Water quality and discharge also varied at Cascade Spring; however, changes did not occur as frequently or as quickly as changes at Wilson Spring. Water quality and discharge at Big Spring at Rutledge Falls changed little in response to storms. Cascade Spring and Big Spring at Rutledge Falls are located in similar hydrogeologic settings on the escarpment of the Highland Rim. Nonisokinetic dip-sampling methods were used to collect VOC samples from the springs during base-flow conditions. During selected storms, automatic samplers were used to collect water samples at Cascade Spring and Wilson Spring. Water samples were collected as frequently as every 15 minutes at the beginning of a storm, and sampling intervals were gradually increased following a storm. VOC samples were analyzed using a portable gas chromatograph (GC). VOC samples were collected from Wilson, Cascade, and Big Springs during 600, 199, and 55 sampling times, respectively, from February 2000 to May 2001. Chloroform concentrations detected at Wilson Spring ranged from 0.073 to 34 mg/L (milligrams per liter). Chloroform concentrations changed during most storms; the greatest change detected was during the first storm in fall 2000, when chloroform concentrations increased from about 0.5 to about 34 mg/L. Concentrations of cis-1,2-dichloroethylene (cis-1,2-DCE) detected at Cascade Spring ranged from 0.30 to 1.8 ?g/L (micrograms per liter) and gradually decreased between November 2000 and May 2001. In addition to the gradual decrease in cis-1,2-DCE concentrations, some additional decreases were detected during storms. VOC samples collected at weekly intervals from Big Spring indicated a gradual decrease in trichloroethylene (TCE) concentrations from approximately 9 to 6 ?g/L between November 2000 and May 2001. Significant changes in TCE concentrations were not detected during individual storms at Big Spring. Quality-control samples included trip blanks, equipment blanks, replicates, and field-matrix spike samples. VOC concentrations measured using the portable GC were similar to concentrations in replicate samples analyzed by the USGS National Water Quality Laboratory (NWQL) with the exception of chloroform and TCE concentrations. Chloroform and TCE concentrations detected by the portable GC were consistently lower (median percent differences of ?19.2 and ?17.4, respectively) than NWQL results. High correlations, however, were observed between concentrations detected by the portable GC and concentrations detected by the NWQL (Pearson?s r > 0.96). VOC concentrations in automatically collected samples were similar to concentrations in replicates collected using dip-sampling methods. More than 80 percent of the VOC concentrations measured in automatically collected samples were within 12 percent of concentrations in dip samples.

  20. Rocky Mountain snowpack physical and chemical data for selected sites, 2009

    USGS Publications Warehouse

    Ingersoll, George P.; Mast, M. Alisa; Swank, James M.; Campbell, Chelsea D.

    2010-01-01

    The Rocky Mountain Snowpack program established a network of snowpack-sampling sites in the Rocky Mountain region from New Mexico to Montana to monitor the chemical content of snow and to understand the effects of regional atmospheric deposition. The U.S. Geological Survey, in cooperation with the National Park Service; the U.S. Department of Agriculture Forest Service; the Colorado Department of Public Health and Environment; Teton County, Wyoming; and others, collected and analyzed snowpack samples annually for 48 or more sites in the Rocky Mountain region during 1993-2009. Sixty-three snowpack-sampling sites were sampled once each in 2009 and data are presented in this report. Data include acid-neutralization capacity, specific conductance, pH, hydrogen ion concentrations, dissolved concentrations of major constituents (calcium, magnesium, sodium, potassium, ammonium, chloride, sulfate, and nitrate), dissolved organic carbon concentrations, snow-water equivalent, snow depth, total mercury concentrations, and ionic charge balance. Quality-assurance data for field and laboratory blanks and field replicates for 2009 also are included.

  1. Radiocarbon Analysis of Individual Amino Acids: Carbon Blank Quantification for a Small-Sample High-Pressure Liquid Chromatography Purification Method.

    PubMed

    Bour, Amy L; Walker, Brett D; Broek, Taylor A B; McCarthy, Matthew D

    2016-04-05

    Compound-specific radiocarbon analysis (CSRA) of amino acids (AAs) is of great interest as a proxy for organic nitrogen (N) cycling rates, dating archeological bone collagen, and investigating processes shaping the biogeochemistry of global N reservoirs. However, recoverable quantities of individual compounds from natural samples are often insufficient for radiocarbon ((14)C) analyses (<50 μg C). Constraining procedural carbon (C) blanks and their isotopic contributions is critical for reporting of accurate CSRA measurements. Here, we report the first detailed quantification of C blanks (including sources, magnitudes, and variability) for a high-pressure liquid chromatography (HPLC) method designed to purify individual AAs from natural samples. We used pairs of AA standards with either modern (M) or dead (D) fraction modern (Fm) values to quantify MC and DC blanks within several chromatographic regions. Blanks were determined for both individual and mixed AA standard injections with peak loadings ranging from 10 to 85 μg C. We found 0.8 ± 0.4 μg of MC and 1.0 ± 0.5 μg of DC were introduced by downstream sample preparation (drying, combustion, and graphitization), which accounted for essentially the entire procedural blank for early eluting AAs. For late-eluting AAs, higher eluent organic content and fraction collected volumes contributed to total blanks of 1.5 ± 0.75 μg of MC and 3.0 ± 1.5 μg of DC. Our final measurement uncertainty for 20 μg of C of most AAs was ±0.02 Fm, although sample size requirements are larger for similar uncertainty in late-eluting AAs. These results demonstrate the first CSRA protocol for many protein AAs with uncertainties comparable to the lowest achieved in prior studies.

  2. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--QA ANALYTICAL RESULTS FOR PARTICULATE MATTER IN BLANK SAMPLES

    EPA Science Inventory

    The Particulate Matter in Blank Samples data set contains the analytical results for measurements of two particle sizes in 12 samples. Filters were pre-weighed, loaded into impactors, kept unexposed in the laboratory, unloaded and post-weighed. Positive weight gains for laborat...

  3. Water-quality data for water- and wastewater-treatment plants along the Red River of the North, North Dakota and Minnesota, January through October 2006

    USGS Publications Warehouse

    Damschen, William C.; Hansel, John A.; Nustad, Rochelle A.

    2008-01-01

    From January through October 2006, six sets of water-quality samples were collected at 28 sites, which included inflow and outflow from seven major municipal water-treatment plants (14 sites) and influent and effluent samples from seven major municipal wastewater treatment plants (14 sites) along the Red River of the North in North Dakota and Minnesota. Samples were collected in cooperation with the Bureau of Reclamation for use in the development of return-flow boundary conditions in a 2006 water-quality model for the Red River of the North. All samples were analyzed for nutrients and major ions. For one set of effluent samples from each of the wastewater-treatment plants, water was analyzed for Eschirichia coli, fecal coliform, 20-day biochemical oxygen demand, 20-day nitrogenous biochemical oxygen demand, total organic carbon, and dissolved organic carbon. In general, results from the field equipment blank and replicate samples indicate that the overall process of sample collection, processing, and analysis did not introduce substantial contamination and that consistent results were obtained.

  4. Concentration data for anthropogenic organic compounds in groundwater, surface water, and finished water of selected community water systems in the United States, 2002-10

    USGS Publications Warehouse

    Carter, Janet M.; Kingsbury, James A.; Hopple, Jessica A.; Delzer, Gregory C.

    2010-01-01

    The National Water-Quality Assessment Program of the U.S. Geological Survey began implementing Source Water-Quality Assessments (SWQAs) in 2001 that focus on characterizing the quality of source water and finished water of aquifers and major rivers used by some of the larger community water systems in the United States. As used in SWQA studies, source water is the raw (ambient) water collected at the supply well before water treatment (for groundwater) or the raw (ambient) water collected from the river near the intake (for surface water), and finished water is the water that has been treated and is ready to be delivered to consumers. Finished-water samples are collected before the water enters the distribution system. The primary objective of SWQAs is to determine the occurrence of more than 250 anthropogenic organic compounds in source water used by community water systems, many of which currently are unregulated in drinking water by the U.S. Environmental Protection Agency. A secondary objective is to understand recurrence patterns in source water and determine if these patterns also occur in finished water before distribution. SWQA studies were conducted in two phases for most studies completed by 2005, and in one phase for most studies completed since 2005. Analytical results are reported for a total of 295 different anthropogenic organic compounds monitored in source-water and finished-water samples collected during 2002-10. The 295 compounds were classified according to the following 13 primary use or source groups: (1) disinfection by-products; (2) fumigant-related compounds; (3) fungicides; (4) gasoline hydrocarbons, oxygenates, and oxygenate degradates; (5) herbicides and herbicide degradates; (6) insecticides and insecticide degradates; (7) manufacturing additives; (8) organic synthesis compounds; (9) pavement- and combustion-derived compounds; (10) personal-care and domestic-use products; (11) plant- or animal-derived biochemicals; (12) refrigerants and propellants; and (13) solvents. This report presents the analytical results of source- water samples from 448 community water system wells and 21 surface-water sites. This report also presents the analytical results of finished-water samples from 285 wells and 20 surface-water sites from community water systems. Results of quality-assurance/quality-control samples also are presented including data for equipment blanks, field blanks, source solution blanks, and replicate samples.

  5. Preliminary evaluation of new polymer matrix for solid-phase extraction of nonylphenol from water samples.

    PubMed

    Guerreiro, António; Soares, Ana; Piletska, Elena; Mattiasson, Bo; Piletsky, Sergey

    2008-03-31

    Molecularly imprinted (MIP) and blank polymers with affinity for nonylphenol were designed using computational modelling. Chromatographic tests demonstrated higher affinity of imprinted polymers towards the template nonylphenol as compared with blank polymers. The performance of both polymers in solid-phase extraction was however very similar. Both blank and imprinted polymers appeared to be suitable for the removal and pre-concentration of nonylphenol from contaminated water samples with 99% efficiency of the recovery. The commercial resins PH(EC) (Biotage) and C18 (Varian) tested in the same conditions used for comparative purposes had recovery rate <84%. The polymer capacity for nonylphenol was 231 mg g(-1) for blank and 228 mg g(-1) for MIP. The synthesised materials can have significance for sample pre-concentration and environmental analysis of this class of compounds.

  6. Blank corrections for ramped pyrolysis radiocarbon dating of sedimentary and soil organic carbon.

    PubMed

    Fernandez, Alvaro; Santos, Guaciara M; Williams, Elizabeth K; Pendergraft, Matthew A; Vetter, Lael; Rosenheim, Brad E

    2014-12-16

    Ramped pyrolysis (RP) targets distinct components of soil and sedimentary organic carbon based on their thermochemical stabilities and allows the determination of the full spectrum of radiocarbon ((14)C) ages present in a soil or sediment sample. Extending the method into realms where more precise ages are needed or where smaller samples need to be measured involves better understanding of the blank contamination associated with the method. Here, we use a compiled data set of RP measurements of samples of known age to evaluate the mass of the carbon blank and its associated (14)C signature, and to assess the performance of the RP system. We estimate blank contamination during RP using two methods, the modern-dead and the isotope dilution method. Our results indicate that during one complete RP run samples are contaminated by 8.8 ± 4.4 μg (time-dependent) of modern carbon (MC, fM ∼ 1) and 4.1 ± 5.5 μg (time-independent) of dead carbon (DC, fM ∼ 0). We find that the modern-dead method provides more accurate estimates of uncertainties in blank contamination; therefore, the isotope dilution method should be used with caution when the variability of the blank is high. Additionally, we show that RP can routinely produce accurate (14)C dates with precisions ∼100 (14)C years for materials deposited in the last 10,000 years and ∼300 (14)C years for carbon with (14)C ages of up to 20,000 years.

  7. Groundwater quality data from the National Water-Quality Assessment Project, May 2012 through December 2013

    USGS Publications Warehouse

    Arnold, Terri L.; Desimone, Leslie A.; Bexfield, Laura M.; Lindsey, Bruce D.; Barlow, Jeannie R.; Kulongoski, Justin T.; Musgrove, MaryLynn; Kingsbury, James A.; Belitz, Kenneth

    2016-06-20

    Groundwater-quality data were collected from 748 wells as part of the National Water-Quality Assessment Project of the U.S. Geological Survey National Water-Quality Program from May 2012 through December 2013. The data were collected from four types of well networks: principal aquifer study networks, which assess the quality of groundwater used for public water supply; land-use study networks, which assess land-use effects on shallow groundwater quality; major aquifer study networks, which assess the quality of groundwater used for domestic supply; and enhanced trends networks, which evaluate the time scales during which groundwater quality changes. Groundwater samples were analyzed for a large number of water-quality indicators and constituents, including major ions, nutrients, trace elements, volatile organic compounds, pesticides, and radionuclides. These groundwater quality data are tabulated in this report. Quality-control samples also were collected; data from blank and replicate quality-control samples are included in this report.

  8. A new processing scheme for ultra-high resolution direct infusion mass spectrometry data

    NASA Astrophysics Data System (ADS)

    Zielinski, Arthur T.; Kourtchev, Ivan; Bortolini, Claudio; Fuller, Stephen J.; Giorio, Chiara; Popoola, Olalekan A. M.; Bogialli, Sara; Tapparo, Andrea; Jones, Roderic L.; Kalberer, Markus

    2018-04-01

    High resolution, high accuracy mass spectrometry is widely used to characterise environmental or biological samples with highly complex composition enabling the identification of chemical composition of often unknown compounds. Despite instrumental advancements, the accurate molecular assignment of compounds acquired in high resolution mass spectra remains time consuming and requires automated algorithms, especially for samples covering a wide mass range and large numbers of compounds. A new processing scheme is introduced implementing filtering methods based on element assignment, instrumental error, and blank subtraction. Optional post-processing incorporates common ion selection across replicate measurements and shoulder ion removal. The scheme allows both positive and negative direct infusion electrospray ionisation (ESI) and atmospheric pressure photoionisation (APPI) acquisition with the same programs. An example application to atmospheric organic aerosol samples using an Orbitrap mass spectrometer is reported for both ionisation techniques resulting in final spectra with 0.8% and 8.4% of the peaks retained from the raw spectra for APPI positive and ESI negative acquisition, respectively.

  9. Mercury Deposition Network Site Operator Training for the System Blank and Blind Audit Programs

    USGS Publications Warehouse

    Wetherbee, Gregory A.; Lehmann, Christopher M.B.

    2008-01-01

    The U.S. Geological Survey operates the external quality assurance project for the National Atmospheric Deposition Program/Mercury Deposition Network. The project includes the system blank and blind audit programs for assessment of total mercury concentration data quality for wet-deposition samples. This presentation was prepared to train new site operators and to refresh experienced site operators to successfully process and submit system blank and blind audit samples for chemical analysis. Analytical results are used to estimate chemical stability and contamination levels of National Atmospheric Deposition Program/Mercury Deposition Network samples and to evaluate laboratory variability and bias.

  10. preparation of microgram samples on iron wool for radiocarbon analysis via accelerator mass spectrometry: A closed-system approach

    NASA Astrophysics Data System (ADS)

    Verkouteren, R. Michael; Klouda, George A.; Currie, Lloyd A.; Donahue, Douglas J.; Jull, A. J. Timothy; Linick, T. W.

    1987-11-01

    A technique has been developed at NBS for the production of high quality targets for radiocarbon analysis by accelerator mass spectrometry (AMS). Our process optimizes chemical yields, ion currents and characterizes the chemical blank. The approach encompasses sample combustion to CO 2, catalytic reduction of CO 2 by Zn to CO, reduction to graphitic carbon on high-purity iron wool and in situ formation of a homogeneous iron-carbon bead; all steps are performed in a closed system. The total measurement system blank and variability are considered in the light of contributions from combustion, iron wool, reduction, bead formation and instrument blank. Additionally, use of this approach provides an increase in throughput, i.e. the effective management of large numbers of samples. Chemical yields for 50-800 μg C samples deposited on 15 mg iron wool were greater than 90%. Integrated 12C - ion currents observed were significant, being 4-64% of those observed in pure graphite. These currents are about an order of magnitude greater than those expected from dilution of graphite with an inert substrate. Isotopic accuracy, precision and blank were assessed by measuring the {14C }/{13C } ratios of a series of targets prepared from dead carbon and oxalic acid (SRM 4990C). Each target was typically measured for one hour; bead consumption was estimated at 5% to 10%. System blank subsequent to combustion was equivalent to (2.2 ± 0.5) μg modern carbon (chemistry + instrument); combustion blank currently stands at (0.4 ± 0.1) (SE, n = 6) μg C.

  11. Rocky Mountain snowpack physical and chemical data for selected sites, 2010

    USGS Publications Warehouse

    Ingersoll, George P.; Mast, M. Alisa; Swank, James M.; Campbell, Chelsea D.

    2010-01-01

    The Rocky Mountain Snowpack program established a network of snowpack-sampling sites in the Rocky Mountain region, from New Mexico to Montana, to monitor the chemical content of snow and to understand the effects of regional atmospheric deposition on freshwater systems. Scientists with the U.S. Geological Survey, in cooperation with the National Park Service; the U.S. Department of Agriculture Forest Service; the Colorado Department of Public Health and Environment; Teton County, Wyoming; and others, annually collected and analyzed snow-pack samples at 48 or more sites in the Rocky Mountain region during 1993-2010. Sixty-three snowpack-sampling sites were each sampled once in 2010, and those data are presented in this report. Data include acid-neutralization capacity, specific conductance, pH, hydrogen ion concentrations, dissolved concentrations of major constituents (calcium, magnesium, sodium, potassium, ammonium, chloride, sulfate, and nitrate), dissolved organic carbon concentrations, snow-water equivalent, snow depth, total mercury concentrations, and ionic charge balance. Quality-assurance data for field and laboratory blanks and field replicates for 2010 also are included.

  12. Rocky Mountain Snowpack Physical and Chemical Data for Selected Sites, 1993-2008

    USGS Publications Warehouse

    Ingersoll, George P.; Mast, M. Alisa; Campbell, Donald H.; Clow, David W.; Nanus, Leora; Turk, John T.

    2009-01-01

    The Rocky Mountain Snowpack program established a network of snowpack-sampling sites in the Rocky Mountain region from New Mexico to Montana to monitor the chemical content of snow to help in the understanding of the effects of atmospheric deposition to this region. The U.S. Geological Survey, in cooperation with the National Park Service, the USDA Forest Service, Teton County in Wyoming, Rio Blanco County in Colorado, Pitkin County in Colorado, and others, collected and analyzed snowpack samples annually for 48 or more sites in the Rocky Mountain region during 1993-2008. Forty-eight of the 162 snow-sampling sites have been sampled annually since 1993. Data include acid-neutralization capacity, specific conductance, pH, hydrogen ion concentrations, dissolved concentrations of major constituents (calcium, magnesium, sodium, potassium, ammonium, chloride, sulfate, and nitrate), dissolved organic carbon concentrations, snow/ water equivalent, snow depth, stable sulfur isotope ratios, total mercury concentrations (beginning in 2001), and ionic charge balance. Quality-assurance data for field and laboratory blanks and field replicates for individual years (1993-2008) also are included.

  13. CTEPP NC DATA QA/QC RESULTS

    EPA Science Inventory

    This data set contains the method performance results. This includes field blanks, method blanks, duplicate samples, analytical duplicates, matrix spikes, and surrogate recovery standards.

    The Children’s Total Exposure to Persistent Pesticides and Other Persistent Pollutant (...

  14. Ground-water sampling methods and quality-control data for the Red River of the North basin, Minnesota, North Dakota, and South Dakota, 1993-95

    USGS Publications Warehouse

    Menheer, M.A.; Brigham, M.E.

    1997-01-01

    Quality-control data demonstrated that most constituents measured for this study yielded reproducible data, with low to undetectable contamination from the sampling and analytical procedures. Several constituents were occasionally or frequently detected in blank samples at levels similar to low-concentration ground-water-quality samples. For example, iron was detected in 75 percent of the blank samples, with a maximum concentration of 27 [ig/L, indicating that iron contamination may interfere with its determination at low levels in ground waters. Copper, aluminum, and dissolved organic carbon concentrations in blank samples overlap those determined in ground-waterquality samples, thereby precluding quantitative reporting of those constituents. Most pesticide data are reproducible, with minimal bias. Some pesticides had low but consistent recoveries; these data may be useful if spike and surrogate data are carefully considered. Data for some pesticides measured in this study should not be quantitatively reported or used, because they may underestimate the concentrations of those pesticides in ground waters.

  15. Investigation of 2,4-dinitrophenylhydrazine impregnated adsorbent tubes for the collection of airborne aldehydes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holdren, M.W.; Smith, D.L.; Russell, N.K.

    1988-06-01

    The objective of the study was to investigate the use of 2,4-dinitrophenylhydrazine (DNPH) impregnated adsorbents for sampling airborne aldehydes. Experimental results using a 17 cu m environmental chamber and various spiked amounts of aldehyde material (low ppb levels) showed that the DNPH coated cartridge and the DNPH/acetonitrile impinger methods gave equivalent results. Blank levels of the DNPH-coated cartridges were studied as a function of storage time using various containers and temperature conditions. Canisters pressurized with zero-grade nitrogen provided the best storage device. Lower blank levels were also obtained when the cartridges were stored at lower temperatures. Blank levels appear tomore » equilibrate after six days of storage. To assure that quality data will be obtained, cartridges should be grouped according to batch number and blank levels should be determined prior to any field monitoring effort. Blank cartridge levels should be an order of magnitude lower than sample cartridge level. High performance liquid chromatography with UV detection proved to be a sensitive and stable analytical method for the DNPH derivatives.« less

  16. GC-MS and LC-MS analysis of nerve agents in body fluids: intra-laboratory verification test using spiked plasma and urine samples.

    PubMed

    Koller, Marianne; Becker, Christian; Thiermann, Horst; Worek, Franz

    2010-05-15

    The purpose of this study was to check the applicability of different analytical methods for the identification of unknown nerve agents in human body fluids. Plasma and urine samples were spiked with nerve agents (plasma) or with their metabolites (urine) or were left blank. Seven random samples (35% of all samples) were selected for the verification test. Plasma was worked up for unchanged nerve agents and for regenerated nerve agents after fluoride-induced reactivation of nerve agent-inhibited butyrylcholinesterase. Both extracts were analysed by GC-MS. Metabolites were extracted from plasma and urine, respectively, and were analysed by LC-MS. The urinary metabolites and two blank samples could be identified without further measurements, plasma metabolites and blanks were identified in six of seven samples. The analysis of unchanged nerve agent provided five agents/blanks and the sixth agent after further investigation. The determination of the regenerated agents also provided only five clear findings during the first screening because of a rather noisy baseline. Therefore, the sample preparation was extended by a size exclusion step performed before addition of fluoride which visibly reduced baseline noise and thus improved identification of the two missing agents. The test clearly showed that verification should be performed by analysing more than one biomarker to ensure identification of the agent(s). Copyright (c) 2010 Elsevier B.V. All rights reserved.

  17. 12 CFR Appendix A to Part 1024 - Instructions for Completing HUD-1 and HUD-1a Settlement Statements; Sample HUD-1 and HUD-1a...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... lines are provided in section L for any additional settlement charges. Blank lines are also provided for additional insertions in sections J and K. The names of the recipients of the settlement charges in section L... blank lines. Lines and columns in section J which relate to the Borrower's transaction may be left blank...

  18. 12 CFR Appendix A to Part 1024 - Instructions for Completing HUD-1 and HUD-1A Settlement Statements; Sample HUD-1 and HUD-1A...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... lines are provided in section L for any additional settlement charges. Blank lines are also provided for additional insertions in sections J and K. The names of the recipients of the settlement charges in section L... blank lines. Lines and columns in section J which relate to the Borrower's transaction may be left blank...

  19. Blanks: a computer program for analyzing furniture rough-part needs in standard-size blanks

    Treesearch

    Philip A. Araman

    1983-01-01

    A computer program is described that allows a company to determine the number of edge-glued, standard-size blanks required to satisfy its rough-part needs for a given production period. Yield and cost information also is determined by the program. A list of the program inputs, outputs, and uses of outputs is described, and an example analysis with sample output is...

  20. Field guide for collecting and processing stream-water samples for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.

    1994-01-01

    The U.S. Geological Survey's National Water-Quality Assessment program includes extensive data- collection efforts to assess the quality of the Nations's streams. These studies require analyses of stream samples for major ions, nutrients, sediments, and organic contaminants. For the information to be comparable among studies in different parts of the Nation, consistent procedures specifically designed to produce uncontaminated samples for trace analysis in the laboratory are critical. This field guide describes the standard procedures for collecting and processing samples for major ions, nutrients, organic contaminants, sediment, and field analyses of conductivity, pH, alkalinity, and dissolved oxygen. Samples are collected and processed using modified and newly designed equipment made of Teflon to avoid contamination, including nonmetallic samplers (D-77 and DH-81) and a Teflon sample splitter. Field solid-phase extraction procedures developed to process samples for organic constituent analyses produce an extracted sample with stabilized compounds for more accurate results. Improvements to standard operational procedures include the use of processing chambers and capsule filtering systems. A modified collecting and processing procedure for organic carbon is designed to avoid contamination from equipment cleaned with methanol. Quality assurance is maintained by strict collecting and processing procedures, replicate sampling, equipment blank samples, and a rigid cleaning procedure using detergent, hydrochloric acid, and methanol.

  1. CTEPP-OH DATA QA/QC RESULTS

    EPA Science Inventory

    This data set contains the method performance results for CTEPP-OH. This includes field blanks, method blanks, duplicate samples, analytical duplicates, matrix spikes, and surrogate recovery standards.

    The Children’s Total Exposure to Persistent Pesticides and Other Persisten...

  2. Detection of Organic Constituents Including Chloromethylpropene in the Analyses of the ROCKNEST Drift by Sample Analysis at Mars (SAM)

    NASA Technical Reports Server (NTRS)

    Eigenbrode, J. L.; Glavin, D.; Coll, P.; Summons, R. E.; Mahaffy, P.; Archer, D.; Brunner, A.; Conrad, P.; Freissinet, C.; Martin, M.; hide

    2013-01-01

    key challenge in assessing the habitability of martian environments is the detection of organic matter - a requirement of all life as we know it. The Curiosity rover, which landed on August 6, 2012 in Gale Crater of Mars, includes the Sample Analysis at Mars (SAM) instrument suite capable of in situ analysis of gaseous organic components thermally evolved from sediment samples collected, sieved, and delivered by the MSL rover. On Sol 94, SAM received its first solid sample: scooped sediment from Rocknest that was sieved to <150 m particle size. Multiple 10-40 mg portions of the scoop #5 sample were delivered to SAM for analyses. Prior to their introduction, a blank (empty cup) analysis was performed. This blank served 1) to clean the analytical instrument of SAMinternal materials that accumulated in the gas processing system since integration into the rover, and 2) to characterize the background signatures of SAM. Both the blank and the Rocknest samples showed the presence of hydrocarbon components.

  3. Updated study reporting levels (SRLs) for trace-element data collected for the California Groundwater Ambient Monitoring and Assessment (GAMA) Priority Basin Project, October 2009-March 2013

    USGS Publications Warehouse

    Davis, Tracy A.; Olsen, Lisa D.; Fram, Miranda S.; Belitz, Kenneth

    2014-01-01

    Groundwater samples have been collected in California as part of statewide investigations of groundwater quality conducted by the U.S. Geological Survey for the Groundwater Ambient Monitoring and Assessment (GAMA) Priority Basin Project (PBP). The GAMA-PBP is being conducted in cooperation with the California State Water Resources Control Board to assess and monitor the quality of groundwater resources used for drinking-water supply and to improve public knowledge of groundwater quality in California. Quality-control samples (source-solution blanks, equipment blanks, and field blanks) were collected in order to ensure the quality of the groundwater sample results. Olsen and others (2010) previously determined study reporting levels (SRLs) for trace-element results based primarily on field blanks collected in California from May 2004 through January 2008. SRLs are raised reporting levels used to reduce the likelihood of reporting false detections attributable to contamination bias. The purpose of this report is to identify any changes in the frequency and concentrations of detections in field blanks since the last evaluation and update the SRLs for more recent data accordingly. Constituents analyzed were aluminum (Al), antimony (Sb), arsenic (As), barium (Ba), beryllium (Be), boron (B), cadmium (Cd), chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), lead (Pb), lithium (Li), manganese (Mn), molybdenum (Mo), nickel (Ni), selenium (Se), silver (Ag), strontium (Sr), thallium (Tl), tungsten (W), uranium (U), vanadium (V), and zinc (Zn). Data from 179 field blanks and equipment blanks collected from March 2006 through March 2013 by the GAMA-PBP indicated that for trace elements that had a change in detection frequency and concentration since the previous review, the shift occurred near October 2009, in conjunction with a change in the capsule filters used by the study. Results for 89 field blanks and equipment blanks collected from October 2009 through March 2013 were evaluated for potential contamination bias by using the same approach developed by Olsen and others (2010). Some data collected by the National Water-Quality Assessment (NAWQA) Program for the Southern California Coastal Drainages study unit were included to supplement the GAMA-PBP data. The detection frequency and upper threshold of potential contamination bias (BD-90/90) were determined from field-blank and equipment-blank data for each trace element. The BD-90/90 is the 90th percentile concentration of potential extrinsic contamination calculated by using the binomial probability distribution for greater than 90 percent confidence. Additionally, data from laboratory blanks and blind blanks analyzed by the National Water Quality Laboratory (NWQL) during water years 2010 through 2013, and compiled by the USGS Branch of Quality Systems (BQS), were considered for each trace element. These results were compared to each constituent’s reporting level to determine whether an SRL was necessary to minimize the potential for detections in the groundwater samples, attributed principally to contamination bias. Results of the evaluation were used to set SRLs for trace-element data for about 1,135 samples of groundwater collected by the GAMA-PBP between October 2009 and March 2013. Ten trace elements analyzed (Sb, As, Be, B, Cd, Li, Se, Ag, Tl, and U) had blank results that did not necessitate establishing SRLs during this review or the review by Olsen and others (2010). Five trace elements analyzed (Al, Ba, Cr, Sr, and V) had blank results that necessitated establishing an SRL during the previous review but did not need an SRL starting October 2009. One trace element (Fe) had field and laboratory-blank results that necessitated keeping the previous SRL (6 micrograms per liter [μg/L]). Two trace elements (Ni and W) had quality-control results that warranted decreasing the previous SRL, and five trace elements (Cu, Pb, Mn, Mo, and Zn) had field, laboratory, or blind blank results that warranted establishing an SRL for the first time or increasing the previous SRL. SRLs for Cu (2.1 μg/L), Pb (0.82 μg/L), Mn (0.66 μg/L), Mo (0.023 μg/L), Ni (0.21 μg/L), W (0.023 μg/L), and Zn (6.2 μg/L) were changed to these levels starting October 2009, based on the BD-90/90 concentration for field blanks or the 99th percentile concentration for laboratory or blind blanks. The SRL for Fe was maintained at 6 μg/L, based on the minimum laboratory reporting level for iron. SRLs for these eight constituents were at least an order of magnitude below the regulatory benchmarks established for drinking water for health and aesthetic purposes; therefore, the practice of reporting concentrations below the SRLs as less than or equal to (≤) the measured value would not prevent the identification of values greater than the drinking-water benchmarks. Co was detected in 99 percent of field blanks, and with a BD-90/90 concentration of 0.38 μg/L, all groundwater results starting October 2009 were coded as “reviewed and rejected.” Co does not currently have a regulatory benchmark for drinking water. The primary sources of contamination for trace elements inferred from this review are the equipment or processes used in the field to collect the samples or in the laboratory. In particular, contamination in field blanks of Co and Mn was attributed to the high-capacity 0.45-micrometer pore-size capsule filters that were in regular use beginning in October 2009 by several USGS programs, including the GAMA-PBP and NAWQA Program, for filtering samples for analysis of trace elements. The SRLs determined in this report are intended to be used for GAMA groundwater-quality data for samples collected October 2009 through March 2013, or for as long as quality-control data indicate contamination similar to what was observed in this report; quality-control data should be continuously reviewed and SRLs re-assessed on at least a study-unit basis.

  4. Secure Base Priming Diminishes Conflict-Based Anger and Anxiety

    PubMed Central

    Koren, Tamara; Bartholomew, Kim

    2016-01-01

    This study examines the impact of a visual representation of a secure base (i.e. a secure base prime) on attenuating experimentally produced anger and anxiety. Specifically, we examined the assuaging of negative emotions through exposure to an image of a mother-infant embrace or a heterosexual couple embracing. Subjects seated at a computer terminal rated their affect (Pre Affect) using the Affect Adjective Checklist (AAC) then listened to two sets of intense two person conflicts. After the first conflict exposure they rated affect again (Post 1 AAC). Following the second exposure they saw a blank screen (control condition), pictures of everyday objects (distraction condition) or a photo of two people embracing (Secure Base Prime condition). They then reported emotions using the Post 2 AAC. Compared to either control or distraction subjects, Secure Base Prime (SBP) subjects reported significantly less anger and anxiety. These results were then replicated using an internet sample with control, SBP and two new controls: Smiling Man (to control for expression of positive affect) and Cold Mother (an unsmiling mother with infant). The SBP amelioration of anger and anxiety was replicated with the internet sample. No control groups produced this effect, which was generated only by a combination of positive affect in a physically embracing dyad. The results are discussed in terms of attachment theory and research on spreading activation. PMID:27606897

  5. Summary and evaluation of pesticides in field blanks collected for the National Water-Quality Assessment Program, 1992-95

    USGS Publications Warehouse

    Martin, Jeffrey D.; Gilliom, Robert J.; Schertz, Terry L.

    1999-01-01

    Field blanks did show evidence of contamination by some pesticides. Most of the pesticides detected in field blanks, however, were detected more frequently and at higher concentrations in environmental water samples. Two criteria were used to evaluate the need to consider contamination in water-quality assessments: (1) a ratio of the frequency of pesticide detection in environmental water samples to the frequency of detection in field blanks of 5.0 or less and (2) a ratio of the median concentration detected in environmental water samples to the maximum concentration detected in field blanks of 2.0 or less. These criteria indicate that contamination, for the majority of the pesticide data collected for the NAWQA Program, probably does not need to be considered in the analysis and interpretation of (1) the frequency of pesticide detection or (2) the median concentration of pesticides detected. Contamination must be considered, however, in detection frequency for cispermethrin, pronamide, p,p' -DDE, pebulate, propargite, ethalfluralin, and triallate in surface water and fenuron, benfluralin, pronamide, cis-permethrin, triallate, chlorpyrifos, trifluralin, propanil, p,p' -DDE, bromacil, dacthal, diazinon, and diuron in ground water. Contamination also must be considered in median concentrations detected for pronamide, p,p' -DDE, propargite, napropamide, and triallate in surface water and benfluralin, cis-permethrin, triallate, chlorpyrifos, trifluralin, p,p' -DDE, dacthal, and diazinon in ground water.

  6. Spatial and temporal genetic structure of a river-resident Atlantic salmon (Salmo salar) after millennia of isolation

    PubMed Central

    Sandlund, Odd Terje; Karlsson, Sten; Thorstad, Eva B; Berg, Ole Kristian; Kent, Matthew P; Norum, Ine C J; Hindar, Kjetil

    2014-01-01

    The river-resident Salmo salar (“småblank”) has been isolated from other Atlantic salmon populations for 9,500 years in upper River Namsen, Norway. This is the only European Atlantic salmon population accomplishing its entire life cycle in a river. Hydropower development during the last six decades has introduced movement barriers and changed more than 50% of the river habitat to lentic conditions. Based on microsatellites and SNPs, genetic variation within småblank was only about 50% of that in the anadromous Atlantic salmon within the same river. The genetic differentiation (FST) between småblank and the anadromous population was 0.24. This is similar to the differentiation between anadromous Atlantic salmon in Europe and North America. Microsatellite analyses identified three genetic subpopulations within småblank, each with an effective population size Ne of a few hundred individuals. There was no evidence of reduced heterozygosity and allelic richness in contemporary samples (2005–2008) compared with historical samples (1955–56 and 1978–79). However, there was a reduction in genetic differentiation between sampling localities over time. SNP data supported the differentiation of småblank into subpopulations and revealed downstream asymmetric gene flow between subpopulations. In spite of this, genetic variation was not higher in the lower than in the upper areas. The meta-population structure of småblank probably maintains genetic variation better than one panmictic population would do, as long as gene flow among subpopulations is maintained. Småblank is a unique endemic island population of Atlantic salmon. It is in a precarious situation due to a variety of anthropogenic impacts on its restricted habitat area. Thus, maintaining population size and avoiding further habitat fragmentation are important. PMID:24967074

  7. Ground-Water Quality Data in the Coastal Los Angeles Basin Study Unit, 2006: Results from the California GAMA Program

    USGS Publications Warehouse

    Mathany, Timothy M.; Land, Michael; Belitz, Kenneth

    2008-01-01

    Ground-water quality in the approximately 860 square-mile Coastal Los Angeles Basin study unit (CLAB) was investigated from June to November of 2006 as part of the Statewide Basin Assessment Project of the Ground-Water Ambient Monitoring and Assessment (GAMA) Program. The GAMA Statewide Basin Assessment was developed in response to the Ground-Water Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The Coastal Los Angeles Basin study was designed to provide a spatially unbiased assessment of raw ground-water quality within CLAB, as well as a statistically consistent basis for comparing water quality throughout California. Samples were collected from 69 wells in Los Angeles and Orange Counties. Fifty-five of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (?grid wells?). Fourteen additional wells were selected to evaluate changes in ground-water chemistry or to gain a greater understanding of the ground-water quality within a specific portion of the Coastal Los Angeles Basin study unit ('understanding wells'). Ground-water samples were analyzed for: a large number of synthetic organic constituents [volatile organic compounds (VOCs), gasoline oxygenates and their degradates, pesticides, polar pesticides, and pesticide degradates, pharmaceutical compounds, and potential wastewater-indicators]; constituents of special interest [perchlorate, N-nitrosodimethylamine (NDMA), 1,4-dioxane, and 1,2,3-trichloropropane (1,2,3-TCP)]; inorganic constituents that can occur naturally [nutrients, major and minor ions, and trace elements]; radioactive constituents [gross-alpha and gross-beta radiation, radium isotopes, and radon-222]; and microbial indicators. Naturally occurring isotopes [stable isotopic ratios of hydrogen and oxygen, and activities of tritium and carbon-14] and dissolved noble gases also were measured to help identify the sources and ages of the sampled ground water. Quality-control samples (blanks, replicates, and samples for matrix spikes) were collected at approximately one-fourth of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a significant source of bias. Differences between replicate samples were within acceptable ranges, indicating acceptably low variability. Matrix spike recoveries were within acceptable ranges for most compounds. Assessment of the quality-control information resulted in applying ?V? codes to approximately 0.1 percent of the data collected for ground-water samples (meaning a constituent was detected in blanks as well as the corresponding environmental data). This study did not attempt to evaluate the quality of drinking water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, and (or) blended with other waters to maintain acceptable drinking-water quality. Regulatory thresholds are applied to the treated drinking water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA), California Department of Public Health (CDPH, formerly California Department of Health Services [CADHS]) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only, and are not indicative of compliance or non-compliance with those thresholds. VOCs were detected in alm

  8. Seeing Red and Shooting Blanks: A Study of Red Quasars and Blank Field X-Ray Sources

    NASA Technical Reports Server (NTRS)

    Oliversen, Ronald J. (Technical Monitor); Elvis, Martin

    2004-01-01

    One type of "Blank Field X-ray Source" is now being seen in deep Chandra and XMM-Newton surveys. These are the newly dubbed "XBONGs" (X-ray Bright, Optically Normal Galaxies). The study of the brighter counterparts from ROSAT and XMM- Newton serendipitous surveys is therefore of renewed interest and topicality. We continue to define the properties of the ROSAT sample which is the basis of this grant. We expect to publish the SEDs of these sources soon.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ikonomou, M.G.; Crewe, N.F.; Fischer, M.

    It has been demonstrated that marine mammals accumulate high concentrations of lipophilic organochlorine contaminants in blubber. As predators of the high trophic level they have also been used to evaluate contamination in the marine environment. Sampling of living marine mammals using a microsample (100 to 200 mg) biopsy dart technique offers a potentially invaluable chronicle in assessing levels and types of persistent environmental pollutants from a sample in which age, sex and other genetic information can additionally be ascertained. The authors have explored analytical methodology based on a high sensitivity detection system (HRGC/HRMS) which provides multi-residue determinations from biopsy dartmore » microsamples. Lipid content and the concentrations of PCDDs, PCDFs and non-ortho and mono-ortho substituted PCBs were measured in 100 mg biopsy dart replicates taken from a killer whale carcass and in three strata of the blubber of that carcass. Statistically acceptable results were obtained from the dart replicates which compared very well with those of the blubber strata. Analytical data from 100 mg extractions from an established in house blubber CRM also compared well against a series of 2.5 g extractions of that CRM. The extraction and cleanup procedures used also allow for the determination of other organohalogen contaminants such as DDT and other pesticides, all the remaining PCBs, polychlorinated diphenylethers and brominated residues. The strengths and limitations of the analytical methodology and the biopsy dart as a sampling tool and pollution predicator will be illustrated in terms of method accuracy and precision, glassware and procedural blanks associated with each extraction batch, and the incorporation of an in house micro reference standard.« less

  10. Gravimetric Analysis of Particulate Matter using Air Samplers Housing Internal Filtration Capsules.

    PubMed

    O'Connor, Sean; O'Connor, Paula Fey; Feng, H Amy; Ashley, Kevin

    2014-10-01

    An evaluation was carried out to investigate the suitability of polyvinyl chloride (PVC) internal capsules, housed within air sampling devices, for gravimetric analysis of airborne particles collected in workplaces. Experiments were carried out using blank PVC capsules and PVC capsules spiked with 0,1 - 4 mg of National Institute of Standards and Technology Standard Reference Material ® (NIST SRM) 1648 (Urban Particulate Matter) and Arizona Road Dust (Air Cleaner Test Dust). The capsules were housed within plastic closed-face cassette samplers (CFCs). A method detection limit (MDL) of 0,075 mg per sample was estimated. Precision S r at 0,5 - 4 mg per sample was 0,031 and the estimated bias was 0,058. Weight stability over 28 days was verified for both blanks and spiked capsules. Independent laboratory testing on blanks and field samples verified long-term weight stability as well as sampling and analysis precision and bias estimates. An overall precision estimate Ŝ rt of 0,059 was obtained. An accuracy measure of ±15,5% was found for the gravimetric method using PVC internal capsules.

  11. Gravimetric Analysis of Particulate Matter using Air Samplers Housing Internal Filtration Capsules

    PubMed Central

    O'Connor, Sean; O'Connor, Paula Fey; Feng, H. Amy

    2015-01-01

    Summary An evaluation was carried out to investigate the suitability of polyvinyl chloride (PVC) internal capsules, housed within air sampling devices, for gravimetric analysis of airborne particles collected in workplaces. Experiments were carried out using blank PVC capsules and PVC capsules spiked with 0,1 – 4 mg of National Institute of Standards and Technology Standard Reference Material® (NIST SRM) 1648 (Urban Particulate Matter) and Arizona Road Dust (Air Cleaner Test Dust). The capsules were housed within plastic closed-face cassette samplers (CFCs). A method detection limit (MDL) of 0,075 mg per sample was estimated. Precision Sr at 0,5 - 4 mg per sample was 0,031 and the estimated bias was 0,058. Weight stability over 28 days was verified for both blanks and spiked capsules. Independent laboratory testing on blanks and field samples verified long-term weight stability as well as sampling and analysis precision and bias estimates. An overall precision estimate Ŝrt of 0,059 was obtained. An accuracy measure of ±15,5% was found for the gravimetric method using PVC internal capsules. PMID:26435581

  12. External quality assurance project report for the National Atmospheric Deposition Program’s National Trends Network and Mercury Deposition Network, 2013–14

    USGS Publications Warehouse

    Wetherbee, Gregory A.; Martin, RoseAnn

    2016-07-05

    The Mercury Deposition Network programs include the system blank program and an interlaboratory comparison program. System blank results indicated that maximum total mercury contamination concentrations in samples were less than the third percentile of all Mercury Deposition Network sample concentrations. The Mercury Analytical Laboratory produced chemical concentration results with low bias and variability compared with other domestic and international laboratories that support atmospheric-deposition monitoring.

  13. Basin F Overburden and Soil Sampling and Analysis Study, Rocky Mountain Arsenal

    DTIC Science & Technology

    1982-05-01

    boring sites will be es:ablished via standard :and surveyinS procedures. 3.3 Bor-ng/ Samaling Procidures Upon staking/marking of the bore holes, the folloi...procedure until the interferences have been eliminated. 3.2.2 Samale Testing Step OC (6) (Procedure Blank) The procedure blank consists of the

  14. A simplified approach to the determination of N-nitroso glyphosate in technical glyphosate using HPLC with post-derivatization and colorimetric detection.

    PubMed

    Kim, Manuela; Stripeikis, Jorge; Iñón, Fernando; Tudino, Mabel

    2007-05-15

    A simple and sensitive HPLC post-derivatization method with colorimetric detection has been developed for the determination of N-nitroso glyphosate in samples of technical glyphosate. Separation of the analyte was accomplished using an anionic exchange resin (2.50mmx4.00mm i.d., 15mum particle size, functional group: quaternary ammonium salt) with Na(2)SO(4) 0.0075M (pH 11.5) (flow rate: 1.0mLmin(-1)) as mobile phase. After separation, the eluate was derivatized with a colorimetric reagent containing sulfanilamide 0.3% (w/v), [N-(1-naphtil)ethilendiamine] 0.03% (w/v) and HCl 4.5M in a thermostatized bath at 95 degrees C. Detection was performed at 546nm. All stages of the analytical procedure were optimized taking into account the concept of analytical minimalism: less operation times and costs; lower sample, reagents and energy consumption and minimal waste. The limit of detection (k=3) calculated for 10 blank replicates was 0.04mgL(-1) (0.8mgkg(-1)) in the solid sample which is lower than the maximum tolerable accepted by the Food and Agriculture Organization of the United Nations.

  15. Effect of Pore Size and Porosity on the Biomechanical Properties and Cytocompatibility of Porous NiTi Alloys

    PubMed Central

    Jian, Yu-Tao; Yang, Yue; Tian, Tian; Stanford, Clark; Zhang, Xin-Ping; Zhao, Ke

    2015-01-01

    Five types of porous Nickel-Titanium (NiTi) alloy samples of different porosities and pore sizes were fabricated. According to compressive and fracture strengths, three groups of porous NiTi alloy samples underwent further cytocompatibility experiments. Porous NiTi alloys exhibited a lower Young’s modulus (2.0 GPa ~ 0.8 GPa). Both compressive strength (108.8 MPa ~ 56.2 MPa) and fracture strength (64.6 MPa ~ 41.6 MPa) decreased gradually with increasing mean pore size (MPS). Cells grew and spread well on all porous NiTi alloy samples. Cells attached more strongly on control group and blank group than on all porous NiTi alloy samples (p < 0.05). Cell adhesion on porous NiTi alloys was correlated negatively to MPS (277.2 μm ~ 566.5 μm; p < 0.05). More cells proliferated on control group and blank group than on all porous NiTi alloy samples (p < 0.05). Cellular ALP activity on all porous NiTi alloy samples was higher than on control group and blank group (p < 0.05). The porous NiTi alloys with optimized pore size could be a potential orthopedic material. PMID:26047515

  16. A new set-up for simultaneous high-precision measurements of CO2, δ13C-CO2 and δ18O-CO2 on small ice core samples

    NASA Astrophysics Data System (ADS)

    Jenk, Theo Manuel; Rubino, Mauro; Etheridge, David; Ciobanu, Viorela Gabriela; Blunier, Thomas

    2016-08-01

    Palaeoatmospheric records of carbon dioxide and its stable carbon isotope composition (δ13C) obtained from polar ice cores provide important constraints on the natural variability of the carbon cycle. However, the measurements are both analytically challenging and time-consuming; thus only data exist from a limited number of sampling sites and time periods. Additional analytical resources with high analytical precision and throughput are thus desirable to extend the existing datasets. Moreover, consistent measurements derived by independent laboratories and a variety of analytical systems help to further increase confidence in the global CO2 palaeo-reconstructions. Here, we describe our new set-up for simultaneous measurements of atmospheric CO2 mixing ratios and atmospheric δ13C and δ18O-CO2 in air extracted from ice core samples. The centrepiece of the system is a newly designed needle cracker for the mechanical release of air entrapped in ice core samples of 8-13 g operated at -45 °C. The small sample size allows for high resolution and replicate sampling schemes. In our method, CO2 is cryogenically and chromatographically separated from the bulk air and its isotopic composition subsequently determined by continuous flow isotope ratio mass spectrometry (IRMS). In combination with thermal conductivity measurement of the bulk air, the CO2 mixing ratio is calculated. The analytical precision determined from standard air sample measurements over ice is ±1.9 ppm for CO2 and ±0.09 ‰ for δ13C. In a laboratory intercomparison study with CSIRO (Aspendale, Australia), good agreement between CO2 and δ13C results is found for Law Dome ice core samples. Replicate analysis of these samples resulted in a pooled standard deviation of 2.0 ppm for CO2 and 0.11 ‰ for δ13C. These numbers are good, though they are rather conservative estimates of the overall analytical precision achieved for single ice sample measurements. Facilitated by the small sample requirement, replicate measurements are feasible, allowing the method precision to be improved potentially. Further, new analytical approaches are introduced for the accurate correction of the procedural blank and for a consistent detection of measurement outliers, which is based on δ18O-CO2 and the exchange of oxygen between CO2 and the surrounding ice (H2O).

  17. Quality-Assurance Data for Routine Water Analyses by the U.S. Geological Survey Laboratory in Troy, New York-July 1997 through June 1999

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2006-01-01

    The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance/quality-control data for the time period addressed in this report were stored in the laboratory's SAS data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality- control samples analyzed from July 1997 through June 1999. Results for the quality-control samples for 18 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration and (or) low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, total aluminum, ammonium, calcium, chloride, specific conductance, and sulfate. The data from the potassium and sodium analytical procedures are insufficient for evaluation. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 11 of 13 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. Blank analysis results for chloride showed that 22 percent of blanks did not meet data-quality objectives and results for dissolved organic carbon showed that 31 percent of the blanks did not meet data-quality objectives. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 14 of the 18 analytes. At least 90 percent of the samples met data-quality objectives for all analytes except total aluminum (70 percent of samples met objectives) and potassium (83 percent of samples met objectives). Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality for most constituents over the time period. The P-sample (low-ionic-strength constituents) analysis had good ratings in two of these studies and a satisfactory rating in the third. The results of the T-sample (trace constituents) analysis indicated high data quality with good ratings in all three studies. The N-sample (nutrient constituents) studies had one each of excellent, good, and satisfactory ratings. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 80 percent of the samples met data-quality objectives for 9 of the 13 analytes; the exceptions were dissolved organic carbon, ammonium, chloride, and specific conductance. Data-quality objectives were not met for dissolved organic carbon in two NWRI studies, but all of the samples were within control limits for the last study. Data-quality objectives were not met in 41 percent of samples analyzed for ammonium, 25 percent of samples analyzed for chloride, and 30 percent of samples analyzed for specific conductance. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 84 percent of the samples analyzed for calcium, chloride, magnesium, pH, and potassium. Data-quality objectives were met by 73 percent of those analyzed for sulfate. The data-quality objective was not met for sodium. The data are insufficient for evaluation of the specific conductance results.

  18. Groundwater Quality Data for the Tahoe-Martis Study Unit, 2007: Results from the California GAMA Program

    USGS Publications Warehouse

    Fram, Miranda S.; Munday, Cathy; Belitz, Kenneth

    2009-01-01

    Groundwater quality in the approximately 460-square-mile Tahoe-Martis study unit was investigated in June through September 2007 as part of the Priority Basin Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of the quality of raw groundwater used for public water supplies within the Tahoe-Martis study unit (Tahoe-Martis) and to facilitate statistically consistent comparisons of groundwater quality throughout California. Samples were collected from 52 wells in El Dorado, Placer, and Nevada Counties. Forty-one of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (grid wells), and 11 were selected to aid in evaluation of specific water-quality issues (understanding wells). The groundwater samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOC], pesticides and pesticide degradates, and pharmaceutical compounds), constituents of special interest (perchlorate and N-nitrosodimethylamine [NDMA]), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), radioactive constituents, and microbial indicators. Naturally occurring isotopes (tritium, carbon-14, strontium isotope ratio, and stable isotopes of hydrogen and oxygen of water), and dissolved noble gases also were measured to help identify the sources and ages of the sampled groundwater. In total, 240 constituents and water-quality indicators were investigated. Three types of quality-control samples (blanks, replicates, and samples for matrix spikes) each were collected at 12 percent of the wells, and the results obtained from these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that data for the groundwater samples were not compromised by possible contamination during sample collection, handling or analysis. Differences between replicate samples were within acceptable ranges. Matrix spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, raw water typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw groundwater. However, to provide some context for the results, concentrations of constituents measured in the raw groundwater were compared with regulatory and nonregulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and the California Department of Public Health (CDPH), and with aesthetic and technical thresholds established by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only and do not indicate of compliance or noncompliance with regulatory thresholds. The concentrations of most constituents detected in groundwater samples from the Tahoe-Martis wells were below drinking-water thresholds. Organic compounds (VOCs and pesticides) were detected in about 40 percent of the samples from grid wells, and most concentrations were less than 1/100th of regulatory and nonregulatory health-based thresholds, although the conentration of perchloroethene in one sample was above the USEPA maximum contaminant level (MCL-US). Concentrations of all trace elements and nutrients in samples from grid wells were below regulatory and nonregulatory health-based thresholds, with five exceptions. Concentra

  19. Groundwater-Quality Data in the Madera-Chowchilla Study Unit, 2008: Results from the California GAMA Program

    USGS Publications Warehouse

    Shelton, Jennifer L.; Fram, Miranda S.; Belitz, Kenneth

    2009-01-01

    Groundwater quality in the approximately 860-square-mile Madera-Chowchilla study unit (MADCHOW) was investigated in April and May 2008 as part of the Priority Basin Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of the quality of raw groundwater used for public water supplies within MADCHOW, and to facilitate statistically consistent comparisons of groundwater quality throughout California. Samples were collected from 35 wells in Madera, Merced, and Fresno Counties. Thirty of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (grid wells), and five more were selected to provide additional sampling density to aid in understanding processes affecting groundwater quality (flow-path wells). Detection summaries in the text and tables are given for grid wells only, to avoid over-representation of the water quality in areas adjacent to flow-path wells. Groundwater samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOCs], low-level 1,2-dibromo-3-chloropropane [DBCP] and 1,2-dibromoethane [EDB], pesticides and pesticide degradates, polar pesticides and metabolites, and pharmaceutical compounds), constituents of special interest (N-nitrosodimethylamine [NDMA], perchlorate, and low-level 1,2,3-trichloropropane [1,2,3-TCP]), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), and radioactive constituents (uranium isotopes, and gross alpha and gross beta particle activities). Naturally occurring isotopes and geochemical tracers (stable isotopes of hydrogen, oxygen, and carbon, and activities of tritium and carbon-14), and dissolved noble gases also were measured to help identify the sources and ages of the sampled groundwater. In total, approximately 300 constituents and field water-quality indicators were investigated. Three types of quality-control samples (blanks, replicates, and samples for matrix spikes) each were collected at approximately 11 percent of the wells sampled for each analysis, and the results obtained from these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that data for the groundwater samples were not compromised by possible contamination during sample collection, handling or analysis. Differences between replicate samples were within acceptable ranges. Matrix spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, raw groundwater typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw groundwater. However, to provide some context for the results, concentrations of constituents measured in the raw groundwater were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and the California Department of Public Health (CDPH), and with aesthetic and technical thresholds established by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only, and are not indicative of compliance or non-compliance with regulatory thresholds. The concentrations of most constituents detected in groundwater samples from MADCHOW wells were below drinking-water thresholds. Organic compounds (VOCs and pesticides

  20. Groundwater-Quality Data in the Antelope Valley Study Unit, 2008: Results from the California GAMA Program

    USGS Publications Warehouse

    Schmitt, Stephen J.; Milby Dawson, Barbara J.; Belitz, Kenneth

    2009-01-01

    Groundwater quality in the approximately 1,600 square-mile Antelope Valley study unit (ANT) was investigated from January to April 2008 as part of the Priority Basin Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project was developed in response to the Groundwater Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of the quality of raw groundwater used for public water supplies within ANT, and to facilitate statistically consistent comparisons of groundwater quality throughout California. Samples were collected from 57 wells in Kern, Los Angeles, and San Bernardino Counties. Fifty-six of the wells were selected using a spatially distributed, randomized, grid-based method to provide statistical representation of the study area (grid wells), and one additional well was selected to aid in evaluation of specific water-quality issues (understanding well). The groundwater samples were analyzed for a large number of organic constituents (volatile organic compounds [VOCs], gasoline additives and degradates, pesticides and pesticide degradates, fumigants, and pharmaceutical compounds), constituents of special interest (perchlorate, N-nitrosodimethylamine [NDMA], and 1,2,3-trichloropropane [1,2,3-TCP]), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), and radioactive constituents (gross alpha and gross beta radioactivity, radium isotopes, and radon-222). Naturally occurring isotopes (strontium, tritium, and carbon-14, and stable isotopes of hydrogen and oxygen in water), and dissolved noble gases also were measured to help identify the sources and ages of the sampled groundwater. In total, 239 constituents and water-quality indicators (field parameters) were investigated. Quality-control samples (blanks, replicates, and samples for matrix spikes) were collected at 12 percent of the wells, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a noticeable source of bias in the data for the groundwater samples. Differences between replicate samples generally were within acceptable ranges, indicating acceptably low variability. Matrix spike recoveries were within acceptable ranges for most compoundsThis study did not evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw groundwater. However, to provide some context for the results, concentrations of constituents measured in the raw groundwater were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only, and are not indicative of compliance or non-compliance with drinking water standards. Most constituents that were detected in groundwater samples were found at concentrations below drinking-water thresholds. Volatile organic compounds (VOCs) were detected in about one-half of the samples and pesticides detected in about one-third of the samples; all detections of these constituents were below health-based thresholds. Most detections of trace elements and nutrients in samples from ANT wells were below health-based thresholds. Exceptions include: one detection of nitrite plus nitr

  1. Groundwater Quality Data for the Northern Sacramento Valley, 2007: Results from the California GAMA Program

    USGS Publications Warehouse

    Bennett, Peter A.; Bennett, George L.; Belitz, Kenneth

    2009-01-01

    Groundwater quality in the approximately 1,180-square-mile Northern Sacramento Valley study unit (REDSAC) was investigated in October 2007 through January 2008 as part of the Priority Basin Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project was developed in response to the Groundwater Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of the quality of raw groundwater used for public water supplies within REDSAC and to facilitate statistically consistent comparisons of groundwater quality throughout California. Samples were collected from 66 wells in Shasta and Tehama Counties. Forty-three of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (grid wells), and 23 were selected to aid in evaluation of specific water-quality issues (understanding wells). The groundwater samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOC], pesticides and pesticide degradates, and pharmaceutical compounds), constituents of special interest (perchlorate and N-nitrosodimethylamine [NDMA]), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), radioactive constituents, and microbial constituents. Naturally occurring isotopes (tritium, and carbon-14, and stable isotopes of nitrogen and oxygen in nitrate, stable isotopes of hydrogen and oxygen of water), and dissolved noble gases also were measured to help identify the sources and ages of the sampled ground water. In total, over 275 constituents and field water-quality indicators were investigated. Three types of quality-control samples (blanks, replicates, and sampmatrix spikes) were collected at approximately 8 to 11 percent of the wells, and the results for these samples were used to evaluate the quality of the data obtained from the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a noticeable source of bias in the data for the groundwater samples. Differences between replicate samples were within acceptable ranges for nearly all compounds, indicating acceptably low variability. Matrix-spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, raw groundwater typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw groundwater were compared with regulatory and nonregulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and with aesthetic and technical thresholds established by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only and do not indicate compliance or noncompliance with those thresholds. The concentrations of most constituents detected in groundwater samples from REDSAC were below drinking-water thresholds. Volatile organic compounds (VOC) and pesticides were detected in less than one-quarter of the samples and were generally less than a hundredth of any health-based thresholds. NDMA was detected in one grid well above the NL-CA. Concentrations of all nutrients and trace elements in samples from REDSAC wells were below the health-based thresholds except those of arsenic in three samples, which were above the USEPA maximum contaminant level (MCL-US). However

  2. Groundwater-quality data for the Sierra Nevada study unit, 2008: Results from the California GAMA program

    USGS Publications Warehouse

    Shelton, Jennifer L.; Fram, Miranda S.; Munday, Cathy M.; Belitz, Kenneth

    2010-01-01

    Groundwater quality in the approximately 25,500-square-mile Sierra Nevada study unit was investigated in June through October 2008, as part of the Priority Basin Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The Sierra Nevada study was designed to provide statistically robust assessments of untreated groundwater quality within the primary aquifer systems in the study unit, and to facilitate statistically consistent comparisons of groundwater quality throughout California. The primary aquifer systems (hereinafter, primary aquifers) are defined by the depth of the screened or open intervals of the wells listed in the California Department of Public Health (CDPH) database of wells used for public and community drinking-water supplies. The quality of groundwater in shallower or deeper water-bearing zones may differ from that in the primary aquifers; shallow groundwater may be more vulnerable to contamination from the surface. In the Sierra Nevada study unit, groundwater samples were collected from 84 wells (and springs) in Lassen, Plumas, Butte, Sierra, Yuba, Nevada, Placer, El Dorado, Amador, Alpine, Calaveras, Tuolumne, Madera, Mariposa, Fresno, Inyo, Tulare, and Kern Counties. The wells were selected on two overlapping networks by using a spatially-distributed, randomized, grid-based approach. The primary grid-well network consisted of 30 wells, one well per grid cell in the study unit, and was designed to provide statistical representation of groundwater quality throughout the entire study unit. The lithologic grid-well network is a secondary grid that consisted of the wells in the primary grid-well network plus 53 additional wells and was designed to provide statistical representation of groundwater quality in each of the four major lithologic units in the Sierra Nevada study unit: granitic, metamorphic, sedimentary, and volcanic rocks. One natural spring that is not used for drinking water was sampled for comparison with a nearby primary grid well in the same cell. Groundwater samples were analyzed for organic constituents (volatile organic compounds [VOC], pesticides and pesticide degradates, and pharmaceutical compounds), constituents of special interest (N-nitrosodimethylamine [NDMA] and perchlorate), naturally occurring inorganic constituents (nutrients, major ions, total dissolved solids, and trace elements), and radioactive constituents (radium isotopes, radon-222, gross alpha and gross beta particle activities, and uranium isotopes). Naturally occurring isotopes and geochemical tracers (stable isotopes of hydrogen and oxygen in water, stable isotopes of carbon, carbon-14, strontium isotopes, and tritium), and dissolved noble gases also were measured to help identify the sources and ages of the sampled groundwater. Three types of quality-control samples (blanks, replicates, and samples for matrix spikes) each were collected at approximately 10 percent of the wells sampled for each analysis, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination from sample collection, handling, and analytical procedures was not a significant source of bias in the data for the groundwater samples. Differences between replicate samples were within acceptable ranges, with few exceptions. Matrix-spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, groundwater typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory benchmarks apply to finished drinking water that is served to the consumer, not to untre

  3. Aqueous geochemical data from the analysis of stream water samples collected in August 2004--Taylor Mountains 1:250,000 scale Quadrangle, Alaska

    USGS Publications Warehouse

    Wang, Bronwen; Mueller, Seth; Bailey, Elizabeth; Lee, Greg

    2006-01-01

    We report on the chemical analysis of water samples collected from the Taylor Mountains 1:250,000 quadrangle. Samples were collected as part of the multi-year U.S. Geological Survey's project -- Geologic and Mineral Deposit Data for Alaskan Economic Development. Data presented here are from water samples collected primarily in the northeastern part of the Taylor Mountains quadrangle. The data include samples taken from the Taylor Mountains C1, C2, D1, D2, and D4 1:63,360 scale quadrangles. The data are being released at this time with minimal interpretation. Site selection was based on a regional sampling strategy that focused on first and second order drainages. Water sampling site selection was based on landscape parameters that included physiography, wetland extent, lithological changes, and the cursory field review of the mineralogy from the pan concentrates. Stream water in the Taylor Mountians quadrangle is dominated by bicarbonate (HCO3-), though in a few samples more than 50% of the anionic charge can be attibuted to sulfate ( SO42-). The major-cation chemistry range from Ca/Mg dominated to a mix of Ca/Mg/Na+K. Good agreement was found between the major cation and anions in the duplicate samples. Many trace elements were at or near the method detection limit in these samples but good agreement was found between duplicate samples for elements with detectable concentrations. Major ion concentrations were below detection in all field blanks and the trace elements concentrations generally were below detection. However, Ta (range 0.9 -.1 ug/L) and Zn (1 to 3.5 ug/L) were detected in all blanks and Ba ( 0.24 ug/L) and Th (0.2 ug/L) were detected in one blank. There was good agreement between dupilicate total- and methyl- mercury and DOC samples; however, total mercury, methyl-mercury and dissolve organic carbon (DOC) were detected in the blank at 2.35 ng/L, 0.07 ng/L and 0.57 mg/L, respectively.

  4. Ground-Water Quality Data in the Central Sierra Study Unit, 2006 - Results from the California GAMA Program

    USGS Publications Warehouse

    Ferrari, Matthew J.; Fram, Miranda S.; Belitz, Kenneth

    2008-01-01

    Ground-water quality in the approximately 950 square kilometer (370 square mile) Central Sierra study unit (CENSIE) was investigated in May 2006 as part of the Priority Basin Assessment project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Assessment project was developed in response to the Ground-Water Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). This study was designed to provide a spatially unbiased assessment of the quality of raw ground water used for drinking-water supplies within CENSIE, and to facilitate statistically consistent comparisons of ground-water quality throughout California. Samples were collected from thirty wells in Madera County. Twenty-seven of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (grid wells), and three were selected to aid in evaluation of specific water-quality issues (understanding wells). Ground-water samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOCs], gasoline oxygenates and degradates, pesticides and pesticide degradates), constituents of special interest (N-nitrosodimethylamine, perchlorate, and 1,2,3-trichloropropane), naturally occurring inorganic constituents [nutrients, major and minor ions, and trace elements], radioactive constituents, and microbial indicators. Naturally occurring isotopes [tritium, and carbon-14, and stable isotopes of hydrogen, oxygen, nitrogen, and carbon], and dissolved noble gases also were measured to help identify the sources and ages of the sampled ground water. In total, over 250 constituents and water-quality indicators were investigated. Quality-control samples (blanks, replicates, and samples for matrix spikes) were collected at approximately one-sixth of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Results from field blanks indicated contamination was not a noticeable source of bias in the data for ground-water samples. Differences between replicate samples were within acceptable ranges, indicating acceptably low variability. Matrix spike recoveries were within acceptable ranges for most constituents. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH), and thresholds established for aesthetic concerns (Secondary Maximum Contaminant Levels, SMCL-CA) by CDPH. Therefore, any comparisons of the results of this study to drinking-water standards only is for illustrative purposes and is not indicative of compliance or non-compliance to those standards. Most constituents that were detected in ground-water samples were found at concentrations below drinking-water standards or thresholds. Six constituents? fluoride, arsenic, molybdenum, uranium, gross-alpha radioactivity, and radon-222?were detected at concentrations higher than thresholds set for health-based regulatory purposes. Three additional constituents?pH, iron and manganese?were detected at concentrations above thresholds set for aesthetic concerns. Volatile organic compounds (VOCs) and pesticides, were detected in less than one-third of the samples and generally at less than one one-hundredth of a health-based threshold.

  5. Groundwater Quality Data in the Mojave Study Unit, 2008: Results from the California GAMA Program

    USGS Publications Warehouse

    Mathany, Timothy M.; Belitz, Kenneth

    2009-01-01

    Groundwater quality in the approximately 1,500 square-mile Mojave (MOJO) study unit was investigated from February to April 2008, as part of the Priority Basin Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). MOJO was the 23rd of 37 study units to be sampled as part of the GAMA Priority Basin Project. The MOJO study was designed to provide a spatially unbiased assessment of the quality of untreated ground water used for public water supplies within MOJO, and to facilitate statistically consistent comparisons of groundwater quality throughout California. Samples were collected from 59 wells in San Bernardino and Los Angeles Counties. Fifty-two of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (grid wells), and seven were selected to aid in evaluation of specific water-quality issues (understanding wells). The groundwater samples were analyzed for a large number of organic constituents [volatile organic compounds (VOCs), pesticides and pesticide degradates, and pharmaceutical compounds], constituents of special interest (perchlorate and N-nitrosodimethylamine [NDMA]) naturally occurring inorganic constituents (nutrients, dissolved organic carbon [DOC], major and minor ions, silica, total dissolved solids [TDS], and trace elements), and radioactive constituents (gross alpha and gross beta radioactivity, radium isotopes, and radon-222). Naturally occurring isotopes (stable isotopes of hydrogen, oxygen, and carbon, stable isotopes of nitrogen and oxygen in nitrate, and activities of tritium and carbon-14), and dissolved noble gases also were measured to help identify the sources and ages of the sampled ground water. In total, over 230 constituents and water-quality indicators (field parameters) were investigated. Three types of quality-control samples (blanks, replicates, and matrix spikes) each were collected at approximately 5-8 percent of the wells, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a significant source of bias in the data for the groundwater samples. Differences between replicate samples generally were within acceptable ranges, indicating acceptable analytical reproducibility. Matrix spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, untreated groundwater typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to untreated ground water. However, to provide some context for the results, concentrations of constituents measured in the untreated ground water were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and thresholds established for aesthetic and technical concerns by CDPH. Comparisons between data collected for this study and thresholds for drinking-water are for illustrative purposes only, and are not indicative of compliance or non-compliance with those thresholds. Most constituents that were detected in groundwater samples in the 59 wells in MOJO were found at concentrations below drinking-water thresholds. In MOJO's 52 grid wells, volatile organic compounds (VOCs) were detected in 40 percent of the wells, and pesticides and pesticide degradates were detected in 23 percent of the grid wel

  6. Groundwater-Quality Data in the Colorado River Study Unit, 2007: Results from the California GAMA Program

    USGS Publications Warehouse

    Goldrath, Dara A.; Wright, Michael T.; Belitz, Kenneth

    2010-01-01

    Groundwater quality in the 188-square-mile Colorado River Study unit (COLOR) was investigated October through December 2007 as part of the Priority Basin Project of the California State Water Resources Control Board (SWRCB) Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project was developed in response to the Groundwater Quality Monitoring Act of 2001, and the U.S. Geological Survey (USGS) is the technical project lead. The Colorado River study was designed to provide a spatially unbiased assessment of the quality of raw groundwater used for public water supplies within COLOR, and to facilitate statistically consistent comparisons of groundwater quality throughout California. Samples were collected from 28 wells in three study areas in San Bernardino, Riverside, and Imperial Counties. Twenty wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the Study unit; these wells are termed 'grid wells'. Eight additional wells were selected to evaluate specific water-quality issues in the study area; these wells are termed `understanding wells.' The groundwater samples were analyzed for organic constituents (volatile organic compounds [VOC], gasoline oxygenates and degradates, pesticides and pesticide degradates, pharmaceutical compounds), constituents of special interest (perchlorate, 1,4-dioxane, and 1,2,3-trichlorpropane [1,2,3-TCP]), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), and radioactive constituents. Concentrations of naturally occurring isotopes (tritium, carbon-14, and stable isotopes of hydrogen and oxygen in water), and dissolved noble gases also were measured to help identify the sources and ages of the sampled groundwater. In total, approximately 220 constituents and water-quality indicators were investigated. Quality-control samples (blanks, replicates, and matrix spikes) were collected at approximately 30 percent of the wells, and the results were used to evaluate the quality of the data obtained from the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a significant source of bias in the data. Differences between replicate samples were within acceptable ranges and matrix-spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, raw groundwater typically is treated, disinfected, or blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw groundwater. However, to provide some context for the results, concentrations of constituents measured in the raw groundwater were compared to regulatory and nonregulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and the California Department of Public Health (CDPH) and to thresholds established for aesthetic concerns by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only and do not indicate compliance or noncompliance with those thresholds. The concentrations of most constituents detected in groundwater samples were below drinking-water thresholds. Volatile organic compounds (VOC) were detected in approximately 35 percent of grid well samples; all concentrations were below health-based thresholds. Pesticides and pesticide degradates were detected in about 20 percent of all samples; detections were below health-based thresholds. No concentrations of constituents of special interest or nutrients were detected above health-based thresholds. Most of the major and minor ion constituents sampled do not have health-based thresholds; the exception is chloride. Concentrations of chloride, sulfate, and total dis

  7. Whole air canister sampling coupled with preconcentration GC/MS analysis of part-per-trillion levels of trimethylsilanol in semiconductor cleanroom air.

    PubMed

    Herrington, Jason S

    2013-08-20

    The costly damage airborne trimethylsilanol (TMS) exacts on optics in the semiconductor industry has resulted in the demand for accurate and reliable methods for measuring TMS at trace levels (i.e., parts per trillion, volume per volume of air [ppt(v)] [~ng/m(3)]). In this study I developed a whole air canister-based approach for field sampling trimethylsilanol in air, as well as a preconcentration gas chromatography/mass spectrometry laboratory method for analysis. The results demonstrate clean canister blanks (0.06 ppt(v) [0.24 ng/m(3)], which is below the detection limit), excellent linearity (a calibration relative response factor relative standard deviation [RSD] of 9.8%) over a wide dynamic mass range (1-100 ppt(v)), recovery/accuracy of 93%, a low selected ion monitoring method detection limit of 0.12 ppt(v) (0.48 ng/m(3)), replicate precision of 6.8% RSD, and stability (84% recovery) out to four days of storage at room temperature. Samples collected at two silicon wafer fabrication facilities ranged from 10.0 to 9120 ppt(v) TMS and appear to be associated with the use of hexamethyldisilazane priming agent. This method will enable semiconductor cleanroom managers to monitor and control for trace levels of trimethylsilanol.

  8. Nutritional characterisation of Pleurotus ostreatus (Jacq. ex Fr.) P. Kumm. produced using paper scraps as substrate.

    PubMed

    Fernandes, Ângela; Barros, Lillian; Martins, Anabela; Herbert, Paulo; Ferreira, Isabel C F R

    2015-02-15

    Pleurotus ostreatus (Jacq. ex Fr.) P. Kumm. is the third most produced edible mushroom worldwide, due to its ability to colonise and degrade a large variety of lignocellulosic substrates. Therefore, the objective of this work was to evaluate the chemical composition of fruiting bodies of P. ostreatus grown on blank and printed paper substrates, in comparison with samples grown on oat straw (control). The nutritional properties of the control sample were similar to values reported in the literature, while the chemical composition of the samples obtained using paper scraps, either blank or printed, was highly satisfactory. The results obtained validated the nutritional characteristics of the samples, highlighting a profitable means to recycle paper. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Groundwater-Quality Data in the South Coast Interior Basins Study Unit, 2008: Results from the California GAMA Program

    USGS Publications Warehouse

    Mathany, Timothy M.; Kulongoski, Justin T.; Ray, Mary C.; Belitz, Kenneth

    2009-01-01

    Groundwater quality in the approximately 653-square-mile South Coast Interior Basins (SCI) study unit was investigated from August to December 2008, as part of the Priority Basins Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basins Project was developed in response to Legislative mandates (Supplemental Report of the 1999 Budget Act 1999-00 Fiscal Year; and, the Groundwater-Quality Monitoring Act of 2001 [Sections 10780-10782.3 of the California Water Code, Assembly Bill 599]) to assess and monitor the quality of groundwater used as public supply for municipalities in California, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). SCI was the 27th study unit to be sampled as part of the GAMA Priority Basins Project. This study was designed to provide a spatially unbiased assessment of the quality of untreated groundwater used for public water supplies within SCI, and to facilitate statistically consistent comparisons of groundwater quality throughout California. Samples were collected from 54 wells within the three study areas [Livermore, Gilroy, and Cuyama] of SCI in Alameda, Santa Clara, San Benito, Santa Barbara, Ventura, and Kern Counties. Thirty-five of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study unit (grid wells), and 19 were selected to aid in evaluation of specific water-quality issues (understanding wells). The groundwater samples were analyzed for organic constituents [volatile organic compounds (VOCs), pesticides and pesticide degradates, polar pesticides and metabolites, and pharmaceutical compounds], constituents of special interest [perchlorate and N-nitrosodimethylamine (NDMA)], naturally occurring inorganic constituents [trace elements, nutrients, major and minor ions, silica, total dissolved solids (TDS), and alkalinity], and radioactive constituents [gross alpha and gross beta radioactivity and radon-222]. Naturally occurring isotopes [stable isotopes of hydrogen, oxygen, and carbon, and activities of tritium and carbon-14] and dissolved noble gases also were measured to help identify the sources and ages of the sampled groundwater. In total, 288 constituents and water-quality indicators (field parameters) were investigated. Three types of quality-control samples (blanks, replicates, and matrix spikes) each were collected at approximately 4-11 percent of the wells, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a significant source of bias in the data obtained from the groundwater samples. Differences between replicate samples generally were less than 10 percent relative standard deviation, indicating acceptable analytical reproducibility. Matrix spike recoveries were within the acceptable range (70 to 130 percent) for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, untreated groundwater typically is treated, disinfected, and/or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to untreated groundwater. However, to provide some context for the results, concentrations of constituents measured in the untreated groundwater were compared with regulatory and nonregulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH), and to nonregulatory thresholds established for aesthetic and technical concerns by CDPH. Comparisons between data collected for this study and thresholds for drinking water are for illustrative purposes only, and are not indicative of complia

  10. ZERODUR thermo-mechanical modelling and advanced dilatometry for the ELT generation

    NASA Astrophysics Data System (ADS)

    Jedamzik, Ralf; Kunisch, Clemens; Westerhoff, Thomas

    2016-07-01

    Large amounts of low thermal expansion material are required for the upcoming ELT projects. The main mirror is designed using several hundreds of hexagonal 1.4 m sized mirror blanks. The M2 and M3 are monolithic 4 m class mirror blanks. The mirror blank material needs to fulfill tight requirements regarding CTE specification and homogeneity. Additionally the mirror blanks need to be dimensionally stable for more than 30 years. In particular, stress effects due to the changes in the environment shall not entail shape variation of more than 0.5 μm PV within 30 years. In 2010 SCHOTT developed a physically based model to describe the thermal and mechanical long time behavior of ZERODUR. The model enables simulation of the long time behavior of ZERODUR mirror blanks under realistic mechanical and thermal constraints. This presentation shows FEM simulation results on the long time behavior of the ELT M1, M2 and M3 mirror blanks under different loading conditions. Additionally the model results will be compared to an already 15 years lasting long time measurement of a ZERODUR sample at the German federal physical standardization institute (PTB). In recent years SCHOTT pushed the push rod dilatometer measurement technology to its limit. With the new Advanced Dilatometer CTE measurement accuracies of +- 3 ppb/K and reproducibilities of better 1 ppb/K have been achieved. The new Advanced Dilatometer exhibits excellent long time stability.

  11. Investigation of the effects of process sequence on the contact resistance characteristics of coated metallic bipolar plates for polymer electrolyte membrane fuel cells

    NASA Astrophysics Data System (ADS)

    Turan, Cabir; Cora, Ömer Necati; Koç, Muammer

    2013-12-01

    In this study, results of an investigation on the effects of manufacturing and coating process sequence on the contact resistance (ICR) of metallic bipolar plates (BPP) for polymer electrolyte membrane fuel cells (PEMFCs) are presented. Firstly, uncoated stainless steel 316L blanks were formed into BPP through hydroforming and stamping processes. Then, these formed BPP samples were coated with three different PVD coatings (CrN, TiN and ZrN) at three different thicknesses (0.1, 0.5 and 1 μm). Secondly, blanks of the same alloy were coated first with the same coatings, thickness and technique; then, they were formed into BPPs of the same shape and dimensions using the manufacturing methods as in the first group. Finally, these two groups of BPP samples were tested for their ICR to reveal the effect of process sequence. ICR tests were also conducted on the BPP plates both before and after exposure to corrosion to disclose the effect of corrosion on ICR. Coated-then-formed BPP samples exhibited similar or even better ICR performance than formed-then-coated BPP samples. Thus, manufacturing of coated blanks can be concluded to be more favorable and worth further investigation in quest of making cost effective BPPs for mass production of PEMFC.

  12. 24 CFR Appendix A to Part 3500 - Instructions for Completing HUD-1 and HUD-1a Settlement Statements; Sample HUD-1 and HUD-1a...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 803 and recorded in the columns. Blank lines are provided in section L for any additional settlement... recipients of the settlement charges in section L and the names of the recipients of adjustments described in... Borrower's transaction may be left blank on the copy of the HUD-1 which will be furnished to the Seller...

  13. Water-quality effects and characterization of indicators of onsite wastewater disposal systems in the east-central Black Hills area, South Dakota, 2006-08

    USGS Publications Warehouse

    Putnam, Larry D.; Hoogestraat, Galen K.; Sawyer, J. Foster

    2008-01-01

    Onsite wastewater disposal systems (OWDS) are used extensively in the Black Hills of South Dakota where many of the watersheds and aquifers are characterized by fractured or solution-enhanced bedrock with thin soil cover. A study was conducted during 2006-08 to characterize water-quality effects and indicators of OWDS. Water samples were collected and analyzed for potential indicators of OWDS, including chloride, bromide, boron, nitrite plus nitrate (NO2+NO3), ammonia, major ions, nutrients, selected trace elements, isotopes of nitrate, microbiological indicators, and organic wastewater compounds (OWCs). The microbiological indicators were fecal coliforms, Escherichia coli (E. coli), enterococci, Clostridium perfringens (C. perfringens), and coliphages. Sixty ground-water sampling sites were located either downgradient from areas of dense OWDS or in background areas and included 25 monitoring wells, 34 private wells, and 1 spring. Nine surface-water sampling sites were located on selected streams and tributaries either downstream or upstream from residential development within the Precambrian setting. Sampling results were grouped by their hydrogeologic setting: alluvial, Spearfish, Minnekahta, and Precambrian. Mean downgradient dissolved NO2+NO3 concentrations in ground water for the alluvial, Spearfish, Minnekahta, and Precambrian settings were 0.734, 7.90, 8.62, and 2.25 milligrams per liter (mg/L), respectively. Mean downgradient dissolved chloride concentrations in ground water for these settings were 324, 89.6, 498, and 33.2 mg/L, respectively. Mean downgradient dissolved boron concentrations in ground water for these settings were 736, 53, 64, and 43 micrograms per liter (ug/L), respectively. Mean dissolved surface-water concentrations for NO2+NO3, chloride, and boron for downstream sites were 0.222 mg/L, 32.1 mg/L, and 28 ug/L, respectively. Mean values of delta-15N and delta-18O (isotope ratios of 14N to 15N and 18O to 16O relative to standard ratios) for nitrate in ground-water samples were 10.4 and -2.0 per mil (0/100), respectively, indicating a relatively small contribution from synthetic fertilizer and probably a substantial contribution from OWDS. The surface-water sample with the highest dissolved NO2+NO3 concentration of 1.6 mg/L had a delta-15N value of 12.36 0/100, which indicates warm-blooded animals (including humans) as the nitrate source. Fecal coliforms were detected in downgradient ground water most frequently in the Spearfish (19 percent) and Minnekahta (9.7 percent) settings. E. coli was detected most frequently in the Minnekahta (29 percent) and Spearfish (13 percent) settings. Enterococci were detected more frequently than other microbiological indicators in all four settings. Fecal coliforms and E. coli were detected in 73 percent and 95 percent of all surface-water samples, respectively. Enterococci, coliphages (somatic), and C. perfringens were detected in 50, 70, and 50 percent of surface-water samples, respectively. Of the 62 OWC analytes, 12 were detected only in environmental samples, 10 were detected in at least one environmental and one blank sample (not necessarily companion pairs), 2 were detected only in blank samples, and 38 were not detected in any blank, environmental, or replicate sample from either ground or surface water. Eleven different organic compounds were detected in ground-water samples at eight different sites. The most frequently occurring compound was DEET, which was found in 32 percent of the environmental samples, followed by tetrachloroethene, which was detected in 20 percent of the samples. For surface-water samples, 16 organic compounds were detected in 9 of the 10 total samples. The compound with the highest occurrence in surface-water samples was camphor, which was detected in 50 percent of samples. The alluvial setting was characterized by relatively low dissolved NO2+NO3 concentrations, detection of ammonia nitrogen, and relatively high concentr

  14. Collagen proteins exchange O with demineralisation and gelatinisation reagents and also with atmospheric moisture.

    PubMed

    von Holstein, Isabella; von Tersch, Matthew; Coutu, Ashley N; Penkman, Kirsty E H; Makarewicz, Cheryl A; Collins, Matthew J

    2018-01-23

    The oxygen isotope composition of collagen proteins is a potential indicator of adult residential location, useful for provenancing in ecology, archaeology and forensics. In acidic solution, proteins can exchange O from carboxylic acid moieties with reagent O. This study investigated whether this exchange occurs during demineralisation and gelatinisation preparation of bone/ivory collagen. EDTA and HCl demineralisation or gelatinisation reagents were made up in waters with different δ 18 O values, and were used to extract collagen from four skeletal tissue samples. Aliquots of extracted collagen were exposed to two different atmospheric waters, at 120°C and ambient temperature, and subsequently dried in a vacuum oven at 40°C or by freeze drying. Sample δ 18 O values were measured by HT/EA pyrolysis-IRMS using a zero-blank autosampler. Collagen samples exchanged O with both reagent waters and atmospheric water, which altered sample δ 18 O values. Exchange with reagent waters occurred in all extraction methods, but was greater at lower pH. Damage to the collagen samples during extraction increased O exchange. The nature of exchange of O with atmospheric water depended on the temperature of exposure: kinetic fractionation of O was identified at 120°C but not at ambient temperature. Exchange was difficult to quantify due to high variability of δ 18 O value between experimental replicates. Studies of δ 18 O values in collagen proteins should avoid extraction methods using acid solutions. This article is protected by copyright. All rights reserved.

  15. Data from exploratory sampling of groundwater in selected oil and gas areas of coastal Los Angeles County and Kern and Kings Counties in southern San Joaquin Valley, 2014–15: California oil, gas, and groundwater project

    USGS Publications Warehouse

    Dillon, David B.; Davis, Tracy A.; Landon, Matthew K.; Land, Michael T.; Wright, Michael T.; Kulongoski, Justin T.

    2016-12-09

    Exploratory sampling of groundwater in coastal Los Angeles County and Kern and Kings Counties of the southern San Joaquin Valley was done by the U.S. Geological Survey from September 2014 through January 2015 as part of the California State Water Resources Control Board’s Water Quality in Areas of Oil and Gas Production Regional Groundwater Monitoring Program. The Regional Groundwater Monitoring Program was established in response to the California Senate Bill 4 of 2013 mandating that the California State Water Resources Control Board design and implement a groundwater-monitoring program to assess potential effects of well-stimulation treatments on groundwater resources in California. The U.S. Geological Survey is in cooperation with the California State Water Resources Control Board to collaboratively implement the Regional Groundwater Monitoring Program through the California Oil, Gas, and Groundwater Project. Many researchers have documented the utility of different suites of chemical tracers for evaluating the effects of oil and gas development on groundwater quality. The purpose of this exploratory sampling effort was to determine whether tracers reported in the literature could be used effectively in California. This reconnaissance effort was not designed to assess the effects of oil and gas on groundwater quality in the sampled areas. A suite of water-quality indicators and geochemical tracers were sampled at groundwater sites in selected areas that have extensive oil and gas development. Groundwater samples were collected from a total of 51 wells, including 37 monitoring wells at 17 multiple-well monitoring sites in coastal Los Angeles County and 5 monitoring wells and 9 water-production wells in southern San Joaquin Valley, primarily in Kern and Kings Counties. Groundwater samples were analyzed for field waterquality indicators; organic constituents, including volatile and semi-volatile organic compounds and dissolved organic carbon indicators; naturally present inorganic constituents, including trace elements, nutrients, major and minor ions, and iron species; naturally present stable and radioactive isotopes; dissolved noble gases; dissolved standard and hydrocarbon gases, δ13C of methane, ethane, and δ2 H of methane. In total, 249 constituents and water-quality indicators were measured. Four types of quality-control samples (blanks, replicates, matrix spikes, and surrogates spiked in environmental and blank samples) were collected at approximately 10 percent of the wells. The quality-control data were used to determine whether the groundwater-sample data were of sufficient quality for the measured analytes to be used as potential indicators of oil and gas effects. The data from the 51 groundwater samples and from the quality-control samples are presented in this report.

  16. Ground-Water Quality Data in the San Francisco Bay Study Unit, 2007: Results from the California GAMA Program

    USGS Publications Warehouse

    Ray, Mary C.; Kulongoski, Justin T.; Belitz, Kenneth

    2009-01-01

    Ground-water quality in the approximately 620-square-mile San Francisco Bay study unit (SFBAY) was investigated from April through June 2007 as part of the Priority Basin project of the Ground-Water Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin project was developed in response to the Groundwater Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of raw ground-water quality, as well as a statistically consistent basis for comparing water quality throughout California. Samples in SFBAY were collected from 79 wells in San Francisco, San Mateo, Santa Clara, Alameda, and Contra Costa Counties. Forty-three of the wells sampled were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study unit (grid wells). Thirty-six wells were sampled to aid in evaluation of specific water-quality issues (understanding wells). The ground-water samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOC], pesticides and pesticide degradates, pharmaceutical compounds, and potential wastewater-indicator compounds), constituents of special interest (perchlorate and N-nitrosodimethylamine [NDMA]), naturally occurring inorganic constituents (nutrients, major and minor ions, trace elements, chloride and bromide isotopes, and uranium and strontium isotopes), radioactive constituents, and microbial indicators. Naturally occurring isotopes (tritium, carbon-14 isotopes, and stable isotopes of hydrogen, oxygen, nitrogen, boron, and carbon), and dissolved noble gases (noble gases were analyzed in collaboration with Lawrence Livermore National Laboratory) also were measured to help identify the source and age of the sampled ground water. Quality-control samples (blank samples, replicate samples, matrix spike samples) were collected for approximately one-third of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Assessment of the quality-control information from the field blanks resulted in applying 'V' codes to approximately 0.1 percent of the data collected for ground-water samples (meaning a constituent was detected in blanks as well as the corresponding environmental data). See the Appendix section 'Quality-Control-Sample Results'. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, and (or) blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to treated water that is delivered to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. VOCs were detected in about one-half of the grid wells, while pesticides were detected in about one-fifth of the grid wells. Concentrations of all VOCs and pesticides detected in samples from all SFBAY wells were below health-based thresholds. No pharmaceutical compounds were detected in any SFBAY well. One potential wastewater-indicator compound, caffeine, was detected in one grid well in SFBAY. Concentrations of most trace elements and nutrients detected in samples from all SFBAY wells were below health-based thresholds. Exceptions include nitrate, detected above the USEPA maximum contaminant level (MCL-US) in 3samples; arsenic, above the USEPA maximum contaminant level (MCL-US) in 3 samples; c

  17. Performance evaluation of a mitogenome capture and Illumina sequencing protocol using non-probative, case-type skeletal samples: Implications for the use of a positive control in a next-generation sequencing procedure.

    PubMed

    Marshall, Charla; Sturk-Andreaggi, Kimberly; Daniels-Higginbotham, Jennifer; Oliver, Robert Sean; Barritt-Ross, Suzanne; McMahon, Timothy P

    2017-11-01

    Next-generation ancient DNA technologies have the potential to assist in the analysis of degraded DNA extracted from forensic specimens. Mitochondrial genome (mitogenome) sequencing, specifically, may be of benefit to samples that fail to yield forensically relevant genetic information using conventional PCR-based techniques. This report summarizes the Armed Forces Medical Examiner System's Armed Forces DNA Identification Laboratory's (AFMES-AFDIL) performance evaluation of a Next-Generation Sequencing protocol for degraded and chemically treated past accounting samples. The procedure involves hybridization capture for targeted enrichment of mitochondrial DNA, massively parallel sequencing using Illumina chemistry, and an automated bioinformatic pipeline for forensic mtDNA profile generation. A total of 22 non-probative samples and associated controls were processed in the present study, spanning a range of DNA quantity and quality. Data were generated from over 100 DNA libraries by ten DNA analysts over the course of five months. The results show that the mitogenome sequencing procedure is reliable and robust, sensitive to low template (one ng control DNA) as well as degraded DNA, and specific to the analysis of the human mitogenome. Haplotypes were overall concordant between NGS replicates and with previously generated Sanger control region data. Due to the inherent risk for contamination when working with low-template, degraded DNA, a contamination assessment was performed. The consumables were shown to be void of human DNA contaminants and suitable for forensic use. Reagent blanks and negative controls were analyzed to determine the background signal of the procedure. This background signal was then used to set analytical and reporting thresholds, which were designated at 4.0X (limit of detection) and 10.0X (limit of quantiation) average coverage across the mitogenome, respectively. Nearly all human samples exceeded the reporting threshold, although coverage was reduced in chemically treated samples resulting in a ∼58% passing rate for these poor-quality samples. A concordance assessment demonstrated the reliability of the NGS data when compared to known Sanger profiles. One case sample was shown to be mixed with a co-processed sample and two reagent blanks indicated the presence of DNA above the analytical threshold. This contamination was attributed to sequencing crosstalk from simultaneously sequenced high-quality samples to include the positive control. Overall this study demonstrated that hybridization capture and Illumina sequencing provide a viable method for mitogenome sequencing of degraded and chemically treated skeletal DNA samples, yet may require alternative measures of quality control. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  18. Selected quality assurance data for water samples collected by the US Geological Survey, Idaho National Engineering Laboratory, Idaho, 1980 to 1988

    USGS Publications Warehouse

    Wegner, S.J.

    1989-01-01

    Multiple water samples from 115 wells and 3 surface water sites were collected between 1980 and 1988 for the ongoing quality assurance program at the Idaho National Engineering Laboratory. The reported results from the six laboratories involved were analyzed for agreement using descriptive statistics. The constituents and properties included: tritium, plutonium-238, plutonium-239, -240 (undivided), strontium-90, americium-241, cesium-137, total dissolved chromium, selected dissolved trace metals, sodium, chloride, nitrate, selected purgeable organic compounds, and specific conductance. Agreement could not be calculated for purgeable organic compounds, trace metals, some nitrates and blank sample analyses because analytical uncertainties were not consistently reported. However, differences between results for most of these data were calculated. The blank samples were not analyzed for differences. The laboratory results analyzed using descriptive statistics showed a median agreement between all useable data pairs of 95%. (USGS)

  19. Perchlorate and Volatiles in the Brine of Lake Vida (antarctica): Implication for the Analysis of Mars Sediments

    NASA Astrophysics Data System (ADS)

    Kenig, F. P. H.; Chou, L.; McKay, C.; Jackson, W. A.; Doran, P. T.; Murray, A. E.; Fritsen, C. H.

    2015-12-01

    A cold (-13.4 °C), saline (188 psu) evaporative brine is encapsulated in the thick (> 27 m) ice of Lake Vida (McMurdo Dry Valleys, Antarctica). The Lake Vida brine (LVBr), which contains abundant dissolved organic carbon (48.2 mmol/L), support an active but slow microbial community. LVBr contains oxychlorines with 50 μg/L of perchlorate and 11 μg/L of chlorate. The McMurdo Dry Valleys have often been considered as a good Mars analog. The oxychlorine-rich brine of Lake Vida constitutes a potential equivalent to perchlorate-rich preserved saline liquid water on Mars. We report here on the artifacts created by oxychlorines upon analysis of volatiles and volatile organic compounds (VOCs) of LVBr by direct immersion (DI) and head space (HS) solid phase micro extraction (SPME) gas chromatography-mass spectrometry (GCMS). We compare analytical blanks to a standard containing 40 μg/L of perchlorate and to actual LVBr sample runs. All blanks, perchlorate blanks and samples were analyzed using two types of SPME fibers, CarboxenTM/polydimethylsiloxane (PDMS) and divinylbenzene (DVB)/ PDMS. The similarities and differences between our results and those obtained by the Sample Analysis at Mars instruments of the rover Curiosity are discussed. The volatiles evolved from LVBr upon analysis with DI- and HS-SPME GCMS are dominated by CO2, dichloromethane, HCl, and volatile organic sulfur compounds (VOSCs, such as DMS, DMDS). The volatiles also include oxygenated compounds such as acids and ketones, aromatic compounds, hydrocarbons, chlorinated compounds (dominated by dichloromethane). Apart from the VOSCs, short chain hydrocarbons and some functionalized compounds derived from the brine itself, all compounds observed are artifacts formed upon oxychlorine breakdown in the injector of the GCMS. The distribution of aromatic compounds seems to be directly dependant on the type of SPME fiber used. The perchlorate blanks show a clear pattern of carbon limitation, likely affecting the type and abundance of compounds produced. This suggests that carbon limited perchlorates blanks are not satisfactory for comparison to the analysis of oxychlorine containing samples. Acknowledgment: NASA ASTEP NAG5-12889 (PTD), NSF awards ANT-0739681 (AEM, CHF) and ANT-0739698 (PTD, FK) supported this work.

  20. A comparative study of mid-infrared diffuse reflection (DR) and attenuated total reflection (ATR) spectroscopy for the detection of fungal infection on RWA2-corn.

    PubMed

    Kos, Gregor; Krska, Rudolf; Lohninger, Hans; Griffiths, Peter R

    2004-01-01

    An investigation into the rapid detection of mycotoxin-producing fungi on corn by two mid-infrared spectroscopic techniques was undertaken. Corn samples from a single genotype (RWA2, blanks, and contaminated with Fusarium graminearum) were ground, sieved and, after appropriate sample preparation, subjected to mid-infrared spectroscopy using two different accessories (diffuse reflection and attenuated total reflection). The measured spectra were evaluated with principal component analysis (PCA) and the blank and contaminated samples were classified by cluster analysis. Reference data for fungal metabolites were obtained with conventional methods. After extraction and clean-up, each sample was analyzed for the toxin deoxynivalenol (DON) by gas chromatography with electron capture detection (GC-ECD) and ergosterol (a parameter for the total fungal biomass) by high-performance liquid chromatography with diode array detection (HPLC-DAD). The concentration ranges for contaminated samples were 880-3600 microg/kg for ergosterol and 300-2600 microg/kg for DON. Classification efficiency was 100% for ATR spectra. DR spectra did not show as obvious a clustering of contaminated and blank samples. Results and trends were also observed in single spectra plots. Quantification using a PLS1 regression algorithm showed good correlation with DON reference data, but a rather high standard error of prediction (SEP) with 600 microg/kg (DR) and 490 microg/kg (ATR), respectively, for ergosterol. Comparing measurement procedures and results showed advantages for the ATR technique, mainly owing to its ease of use and the easier interpretation of results that were better with respect to classification and quantification.

  1. The Effects of Exercising in Different Natural Environments on Psycho-Physiological Outcomes in Post-Menopausal Women: A Simulation Study.

    PubMed

    White, Mathew P; Pahl, Sabine; Ashbullby, Katherine J; Burton, Francesca; Depledge, Michael H

    2015-09-23

    The current study examined potential psycho-physiological benefits from exercising in simulated natural environments among a sample of post-menopausal women using a laboratory based protocol. Participants cycled on a stationary exercise bike for 15 min while facing either a blank wall (Control) or while watching one of three videos: Urban (Grey), Countryside (Green), Coast (Blue). Blood pressure, heart rate and affective responses were measured pre-post. Heart rate, affect, perceived exertion and time perception were also measured at 5, 10 and 15 min during exercise. Experience evaluation was measured at the end. Replicating most earlier findings, affective, but not physiological, outcomes were more positive for exercise in the simulated Green and, for the first time, Blue environment, compared to Control. Moreover, only the simulated Blue environment was associated with shorter perceived exercise duration than Control and participants were most willing to repeat exercise in the Blue setting. The current research extended earlier work by exploring the effects of "blue exercise" and by using a demographic with relatively low average levels of physical activity. That this sample of postmenopausal women were most willing to repeat a bout of exercise in a simulated Blue environment may be important for physical activity promotion in this cohort.

  2. The Effects of Exercising in Different Natural Environments on Psycho-Physiological Outcomes in Post-Menopausal Women: A Simulation Study

    PubMed Central

    White, Mathew P.; Pahl, Sabine; Ashbullby, Katherine J.; Burton, Francesca; Depledge, Michael H.

    2015-01-01

    The current study examined potential psycho-physiological benefits from exercising in simulated natural environments among a sample of post-menopausal women using a laboratory based protocol. Participants cycled on a stationary exercise bike for 15 min while facing either a blank wall (Control) or while watching one of three videos: Urban (Grey), Countryside (Green), Coast (Blue). Blood pressure, heart rate and affective responses were measured pre-post. Heart rate, affect, perceived exertion and time perception were also measured at 5, 10 and 15 min during exercise. Experience evaluation was measured at the end. Replicating most earlier findings, affective, but not physiological, outcomes were more positive for exercise in the simulated Green and, for the first time, Blue environment, compared to Control. Moreover, only the simulated Blue environment was associated with shorter perceived exercise duration than Control and participants were most willing to repeat exercise in the Blue setting. The current research extended earlier work by exploring the effects of “blue exercise” and by using a demographic with relatively low average levels of physical activity. That this sample of postmenopausal women were most willing to repeat a bout of exercise in a simulated Blue environment may be important for physical activity promotion in this cohort. PMID:26404351

  3. Stacking and determination of phenazine-1-carboxylic acid with low pKa in soil via moving reaction boundary formed by alkaline and double acidic buffers in capillary electrophoresis.

    PubMed

    Sun, Chong; Yang, Xiao-Di; Fan, Liu-Yin; Zhang, Wei; Xu, Yu-Quan; Cao, Cheng-Xi

    2011-04-01

    As shown herein, a normal moving reaction boundary (MRB) formed by an alkaline buffer and a single acidic buffer had poor stacking to the new important plant growth promoter of phenazine-1-carboxylic acid (PCA) in soil due to the leak induced by its low pK(a). To stack the PCA with low pK(a) efficiently, a novel stacking system of MRB was developed, which was formed by an alkaline buffer and double acidic buffers (viz., acidic sample and blank buffers). With the novel system, the PCA leaking into the blank buffer from the sample buffer could be well stacked by the prolonged MRB formed between the alkaline buffer and blank buffer. The relevant mechanism of stacking was discussed briefly. The stacking system, coupled with sample pretreatment, could achieve a 214-fold increase of PCA sensitivity under the optimal conditions (15 mM (pH 11.5) Gly-NaOH as the alkaline buffer, 15 mM (pH 3.0) Gly-HCl-acetonitrile (20%, v/v) as the acidic sample buffer, 15 mM (pH 3.0) Gly-HCl as the blank buffer, 3 min 13 mbar injection of double acidic buffers, benzoic acid as the internal standard, 75 μm i.d. × 53 cm (44 cm effective length) capillary, 25 kV and 248 nm). The limit of detection of PCA in soil was decreased to 17 ng/g, the intra-day and inter-day precision values (expressed as relative standard deviations) were 3.17-4.24% and 4.17-4.87%, respectively, and the recoveries of PCA at three concentration levels changed from 52.20% to 102.61%. The developed method could be used for the detection of PCA in soil at trace level.

  4. [Effect of humidity and temperature on filter and gravimetric measurement of ambient particulate matter in a balance room].

    PubMed

    Su, Wen-jin; Wang, Li-min; Weng, Shao-fan; Wang, Hai-jiao; Du, Li-li; Liu, Yue-wei; Yang, Lei; Chen, Wei-hong

    2008-04-01

    To assess the effects of the alteration of humidity and (or) temperature on weight of filters without and with ambient particulate matter in a balance room. The mass of blank dust sampling filters were weighed under (18 +/- 1) degrees C and (28 +/- 1) degrees C respectively, with the humidity varying from 35% relative humidity (RH) to 100% RH in a balance room. Then the blank filters were divided into two groups and were used to sample total dust and respirable dust. After sampling, the loaded filters were re-weighed under above conditions and the mass difference before and after the sampling were compared and analyzed. The vibration of the average mass of filters varied from 0.10 to 0.13 mg and from 0.06 to 0.09 mg under the temperatures of (18 +/- 1) degrees C and (28 +/- 1) degrees C respectively; When both the temperature and humidity changed, it varied from 0.12 to 0.16 mg. The deviation of average mass difference ranged from 0.07 to 0.10 mg and from 0.04 to 0.08 mg under the two temperatures mentioned above; When both the temperature and humidity changed, it varied from 0.09 to 0.14 mg. The average mass of blank filters and loaded filters were all positively correlated with the change of humidity (P < 0.01). No effects of humidity on the average mass difference of the loaded filters were observed. The average mass differences of loaded filters and blank filters under (18 +/- 1) degrees C were significantly higher than that under (28 +/- 1) degrees C (P < 0.01) when humidity was not changed. The alteration of humidity and (or) temperature in a balance room attributes to the deviation of the measurement of the mass of filters and thus affects the gravimetric measurements of ambient particulate matter.

  5. Groundwater-Quality Data in the South Coast Range-Coastal Study Unit, 2008: Results from the California GAMA Program

    USGS Publications Warehouse

    Mathany, Timothy M.; Burton, Carmen A.; Land, Michael; Belitz, Kenneth

    2010-01-01

    Groundwater quality in the approximately 766-square-mile South Coast Range-Coastal (SCRC) study unit was investigated from May to December 2008, as part of the Priority Basins Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basins Project was developed in response to legislative mandates (Supplemental Report of the 1999 Budget Act 1999-00 Fiscal Year; and, the Groundwater Quality Monitoring Act of 2001 [Sections 10780-10782.3 of the California Water Code, Assembly Bill 599]) to assess and monitor the quality of groundwater in California, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The SCRC study unit was the 25th study unit to be sampled as part of the GAMA Priority Basins Project. The SCRC study unit was designed to provide a spatially unbiased assessment of untreated groundwater quality in the primary aquifer systems and to facilitate statistically consistent comparisons of untreated groundwater quality throughout California. The primary aquifer systems (hereinafter referred to as primary aquifers) were defined as that part of the aquifer corresponding to the perforation interval of wells listed in the California Department of Public Health (CDPH) database for the SCRC study unit. The quality of groundwater in shallow or deep water-bearing zones may differ from the quality of groundwater in the primary aquifers; shallow groundwater may be more vulnerable to surficial contamination. In the SCRC study unit, groundwater samples were collected from 70 wells in two study areas (Basins and Uplands) in Santa Barbara and San Luis Obispo Counties. Fifty-five of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study unit (grid wells), and 15 wells were selected to aid in evaluation of specific water-quality issues (understanding wells). In addition to the 70 wells sampled, 3 surface-water samples were collected in streams near 2 of the sampled wells in order to better comprehend the interaction between groundwater and surface water in the area. The groundwater samples were analyzed for organic constituents (volatile organic compounds [VOC], pesticides and pesticide degradates, polar pesticides and metabolites, and pharmaceutical compounds), constituents of special interest (perchlorate, N-nitrosodimethylamine [NDMA], and 1,2,3-TCP), naturally occurring inorganic constituents (trace elements, nutrients, dissolved organic carbon [DOC], major and minor ions, silica, total dissolved solids [TDS], and alkalinity), and radioactive constituents (gross alpha and gross beta radioactivity). Naturally occurring isotopes (stable isotopes of hydrogen and oxygen in water, stable isotopes of nitrogen and oxygen in dissolved nitrate, stable isotopes of sulfur in dissolved sulfate, stable isotopes of carbon in dissolved inorganic carbon, activities of tritium, and carbon-14 abundance), and dissolved gases (including noble gases) also were measured to help identify the sources and ages of the sampled groundwater. In total, 298 constituents and field water-quality indicators were investigated. Three types of quality-control samples (blanks, replicates, and matrix-spikes) were collected at approximately 3 to 12 percent of the wells in the SCRC study unit, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination from sample collection procedures was not a significant source of bias in the data for the groundwater samples. Differences between replicate samples generally were less than 10 percent relative and/or standard deviation, indicating acceptable analytical reproducibility. Matrix-spike recoveries were within the acceptable range (70 to 130 percent) for approximately 84

  6. Triangle area water supply monitoring project, October 1988 through September 2001, North Carolina -- description of the water-quality network, sampling and analysis methods, and quality-assurance practices

    USGS Publications Warehouse

    Oblinger, Carolyn J.

    2004-01-01

    The Triangle Area Water Supply Monitoring Project was initiated in October 1988 to provide long-term water-quality data for six area water-supply reservoirs and their tributaries. In addition, the project provides data that can be used to determine the effectiveness of large-scale changes in water-resource management practices, document differences in water quality among water-supply types (large multiuse reservoir, small reservoir, run-of-river), and tributary-loading and in-lake data for water-quality modeling of Falls and Jordan Lakes. By September 2001, the project had progressed in four phases and included as many as 34 sites (in 1991). Most sites were sampled and analyzed by the U.S. Geological Survey. Some sites were already a part of the North Carolina Division of Water Quality statewide ambient water-quality monitoring network and were sampled by the Division of Water Quality. The network has provided data on streamflow, physical properties, and concentrations of nutrients, major ions, metals, trace elements, chlorophyll, total organic carbon, suspended sediment, and selected synthetic organic compounds. Project quality-assurance activities include written procedures for sample collection, record management and archive, collection of field quality-control samples (blank samples and replicate samples), and monitoring the quality of field supplies. In addition to project quality-assurance activities, the quality of laboratory analyses was assessed through laboratory quality-assurance practices and an independent laboratory quality-control assessment provided by the U.S. Geological Survey Branch of Quality Systems through the Blind Inorganic Sample Project and the Organic Blind Sample Project.

  7. The 1 MV multi-element AMS system for biomedical applications at the Netherlands Organization for Applied Scientific Research (TNO)

    NASA Astrophysics Data System (ADS)

    Klein, Matthias; Vaes, W. H. J.; Fabriek, B.; Sandman, H.; Mous, D. J. W.; Gottdang, A.

    2013-01-01

    The Netherlands Organization for Applied Scientific Research (TNO) has installed a compact 1 MV multi-element AMS system manufactured by High Voltage Engineering Europa B.V., The Netherlands. TNO performs clinical research programs for pharmaceutical and innovative foods industry to obtain early pharmacokinetic data and to provide anti-osteoporotic efficacy data of new treatments. The AMS system will analyze carbon, iodine and calcium samples for this purpose. The first measurements on blank samples indicate background levels in the low 10-12 for calcium and iodine, making the system well suited for these biomedical applications. Carbon blanks have been measured at low 10-16. For unattended, around-the-clock analysis, the system features the 200 sample version of the SO110 hybrid ion source and user friendly control software.

  8. Procedures for determination of detection limits: application to high-performance liquid chromatography analysis of fat-soluble vitamins in human serum.

    PubMed

    Browne, Richard W; Whitcomb, Brian W

    2010-07-01

    Problems in the analysis of laboratory data commonly arise in epidemiologic studies in which biomarkers subject to lower detection thresholds are used. Various thresholds exist including limit of detection (LOD), limit of quantification (LOQ), and limit of blank (LOB). Choosing appropriate strategies for dealing with data affected by such limits relies on proper understanding of the nature of the detection limit and its determination. In this paper, we demonstrate experimental and statistical procedures generally used for estimating different detection limits according to standard procedures in the context of analysis of fat-soluble vitamins and micronutrients in human serum. Fat-soluble vitamins and micronutrients were analyzed by high-performance liquid chromatography with diode array detection. A simulated serum matrix blank was repeatedly analyzed for determination of LOB parametrically by using the observed blank distribution as well as nonparametrically by using ranks. The LOD was determined by combining information regarding the LOB with data from repeated analysis of standard reference materials (SRMs), diluted to low levels; from LOB to 2-3 times LOB. The LOQ was determined experimentally by plotting the observed relative standard deviation (RSD) of SRM replicates compared with the concentration, where the LOQ is the concentration at an RSD of 20%. Experimental approaches and example statistical procedures are given for determination of LOB, LOD, and LOQ. These quantities are reported for each measured analyte. For many analyses, there is considerable information available below the LOQ. Epidemiologic studies must understand the nature of these detection limits and how they have been estimated for appropriate treatment of affected data.

  9. Quality-assurance data for routine water quality analyses by the U. S. Geological Survey laboratory in Troy, New York; July 1993 through June 1995

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2001-01-01

    A laboratory for analysis of low-ionic strength water has been developed at the U.S. Geological Survey (USGS) office in Troy, N.Y., to analyze samples collected by USGS projects in the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures developed to ensure proper sample collection, processing, and analysis. The quality-assurance/quality-control data are stored in the laboratory's SAS data-management system, which provides efficient review, compilation, and plotting of quality-assurance/quality-control data. This report presents and discusses samples analyzed from July 1993 through June 1995. Quality-control results for 18 analytical procedures were evaluated for bias and precision. Control charts show that data from seven of the analytical procedures were biased throughout the analysis period for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, dissolved inorganic carbon, dissolved organic carbon (soil expulsions), chloride, magnesium, nitrate (colorimetric method), and pH. Three of the analytical procedures were occasionally biased but were within control limits; they were: calcium (high for high-concentration samples for May 1995), dissolved organic carbon (high for highconcentration samples from January through September 1994), and fluoride (high in samples for April and June 1994). No quality-control sample has been developed for the organic monomeric aluminum procedure. Results from the filter-blank and analytical-blank analyses indicate that all analytical procedures in which blanks were run were within control limits, although values for a few blanks were outside the control limits. Blanks were not analyzed for acid-neutralizing capacity, dissolved inorganic carbon, fluoride, nitrate (colorimetric method), or pH. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in 14 of the 18 procedures. Data-quality objectives were met by more than 90 percent of the samples analyzed in all procedures except total monomeric aluminum (85 percent of samples met objectives), total aluminum (70 percent of samples met objectives), and dissolved organic carbon (85 percent of samples met objectives). Triplicate samples were not analyzed for ammonium, fluoride, dissolved inorganic carbon, or nitrate (colorimetric method). Results of the USGS interlaboratory Standard Reference Sample Program indicated high data quality with a median result of 3.6 of a possible 4.0. Environment Canada's LRTAP interlaboratory study results indicated that more than 85 percent of the samples met data-quality objectives in 6 of the 12 analyses; exceptions were calcium, dissolved organic carbon, chloride, pH, potassium, and sodium. Data-quality objectives were not met for calcium samples in one LRTAP study, but 94 percent of samples analyzed were within control limits for the remaining studies. Data-quality objectives were not met by 35 percent of samples analyzed for dissolved organic carbon, but 94 percent of sample values were within 20 percent of the most probable value. Data-quality objectives were not met for 30 percent of samples analyzed for chloride, but 90 percent of sample values were within 20 percent of the most probable value. Measurements of samples with a pH above 6.0 were biased high in 54 percent of the samples, although 85 percent of the samples met data-quality objectives for pH measurements below 6.0. Data-quality objectives for potassium and sodium were not met in one study (only 33 percent of the samples analyzed met the objectives), although 85 percent of the sample values were within control limits for the other studies. Measured sodium values were above the upper control limit in all studies. Results from blind reference-sample analyses indicated that data

  10. Oak ridge national laboratory automated clean chemistry for bulk analysis of environmental swipe samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bostick, Debra A.; Hexel, Cole R.; Ticknor, Brian W.

    2016-11-01

    To shorten the lengthy and costly manual chemical purification procedures, sample preparation methods for mass spectrometry are being automated using commercial-off-the-shelf (COTS) equipment. This addresses a serious need in the nuclear safeguards community to debottleneck the separation of U and Pu in environmental samples—currently performed by overburdened chemists—with a method that allows unattended, overnight operation. In collaboration with Elemental Scientific Inc., the prepFAST-MC2 was designed based on current COTS equipment that was modified for U/Pu separations utilizing Eichrom™ TEVA and UTEVA resins. Initial verification of individual columns yielded small elution volumes with consistent elution profiles and good recovery. Combined columnmore » calibration demonstrated ample separation without crosscontamination of the eluent. Automated packing and unpacking of the built-in columns initially showed >15% deviation in resin loading by weight, which can lead to inconsistent separations. Optimization of the packing and unpacking methods led to a reduction in the variability of the packed resin to less than 5% daily. The reproducibility of the automated system was tested with samples containing 30 ng U and 15 pg Pu, which were separated in a series with alternating reagent blanks. These experiments showed very good washout of both the resin and the sample from the columns as evidenced by low blank values. Analysis of the major and minor isotope ratios for U and Pu provided values well within data quality limits for the International Atomic Energy Agency. Additionally, system process blanks spiked with 233U and 244Pu tracers were separated using the automated system after it was moved outside of a clean room and yielded levels equivalent to clean room blanks, confirming that the system can produce high quality results without the need for expensive clean room infrastructure. Comparison of the amount of personnel time necessary for successful manual vs. automated chemical separations showed a significant decrease in hands-on time from 9.8 hours to 35 minutes for seven samples, respectively. This documented time savings and reduced labor translates to a significant cost savings per sample. Overall, the system will enable faster sample reporting times at reduced costs by limiting personnel hours dedicated to the chemical separation.« less

  11. Ground-Water Quality Data in the Middle Sacramento Valley Study Unit, 2006 - Results from the California GAMA Program

    USGS Publications Warehouse

    Schmitt, Stephen J.; Fram, Miranda S.; Milby Dawson, Barbara J.; Belitz, Kenneth

    2008-01-01

    Ground-water quality in the approximately 3,340 square mile Middle Sacramento Valley study unit (MSACV) was investigated from June through September, 2006, as part of the California Groundwater Ambient Monitoring and Assessment (GAMA) program. The GAMA Priority Basin Assessment project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The Middle Sacramento Valley study was designed to provide a spatially unbiased assessment of raw ground-water quality within MSACV, as well as a statistically consistent basis for comparing water quality throughout California. Samples were collected from 108 wells in Butte, Colusa, Glenn, Sutter, Tehama, Yolo, and Yuba Counties. Seventy-one wells were selected using a randomized grid-based method to provide statistical representation of the study unit (grid wells), 15 wells were selected to evaluate changes in water chemistry along ground-water flow paths (flow-path wells), and 22 were shallow monitoring wells selected to assess the effects of rice agriculture, a major land use in the study unit, on ground-water chemistry (RICE wells). The ground-water samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOCs], gasoline oxygenates and degradates, pesticides and pesticide degradates, and pharmaceutical compounds), constituents of special interest (perchlorate, N-nitrosodimethylamine [NDMA], and 1,2,3-trichloropropane [1,2,3-TCP]), inorganic constituents (nutrients, major and minor ions, and trace elements), radioactive constituents, and microbial indicators. Naturally occurring isotopes (tritium, and carbon-14, and stable isotopes of hydrogen, oxygen, nitrogen, and carbon), and dissolved noble gases also were measured to help identify the sources and ages of the sampled ground water. Quality-control samples (blanks, replicates, laboratory matrix spikes) were collected at approximately 10 percent of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a noticeable source of bias in the data for the ground-water samples. Differences between replicate samples were within acceptable ranges, indicating acceptably low variability. Matrix spike recoveries were within acceptable ranges for most constituents. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, or blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to treated water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only and are not indicative of compliance or noncompliance with regulatory thresholds. Most constituents that were detected in ground-water samples were found at concentrations below drinking-water thresholds. VOCs were detected in less than one-third and pesticides and pesticide degradates in just over one-half of the grid wells, and all detections of these constituents in samples from all wells of the MSACV study unit were below health-based thresholds. All detections of trace elements in samples from MSACV grid wells were below health-based thresholds, with the exceptions of arsenic and boro

  12. Assessment of Hyporheic Zone, Flood-Plain, Soil-Gas, Soil, and Surface-Water Contamination at the McCoys Creek Chemical Training Area, Fort Gordon, Georgia, 2009-2010

    USGS Publications Warehouse

    Guimaraes, Wladmir B.; Falls, W. Fred; Caldwell, Andral W.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.

    2011-01-01

    The U.S. Geological Survey, in cooperation with the U.S. Department of the Army Environmental and Natural Resources Management Office of the U.S. Army Signal Center and Fort Gordon, Georgia, assessed the hyporheic zone, flood plain, soil gas, soil, and surface water for contaminants at the McCoys Creek Chemical Training Area (MCTA) at Fort Gordon, from October 2009 to September 2010. The assessment included the detection of organic contaminants in the hyporheic zone, flood plain, soil gas, and surface water. In addition, the organic contaminant assessment included the analysis of organic compounds classified as explosives and chemical agents in selected areas. Inorganic contaminants were assessed in soil and surface-water samples. The assessment was conducted to provide environmental contamination data to the U.S. Army at Fort Gordon pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. Ten passive samplers were deployed in the hyporheic zone and flood plain, and total petroleum hydrocarbons (TPH) and octane were detected above the method detection level in every sampler. Other organic compounds detected above the method detection level in the hyporheic zone and flood-plain samplers were trichloroethylene, and cis- and trans- 1, 2-dichloroethylene. One trip blank detected TPH below the method detection level but above the nondetection level. The concentrations of TPH in the samplers were many times greater than the concentrations detected in the blank; therefore, all other TPH concentrations detected are considered to represent environmental conditions. Seventy-one soil-gas samplers were deployed in a grid pattern across the MCTA. Three trip blanks and three method blanks were used and not deployed, and TPH was detected above the method detection level in two trip blanks and one method blank. Detection of TPH was observed at all 71 samplers, but because TPH was detected in the trip and method blanks, TPH was censored and, therefore, only 7 of the 71 samplers were reported as detecting TPH. In addition, benzene, toluene, ethylbenzene, and total xylene were detected above the method detection level in 22 samplers. Other compounds detected above the method detection level included naphthalene, octane, undecane, tridecane, 1,2,4-trimethylbenzene, trichloroethylene, perchloroethylene, chloroform, and 1,4-dichlorobenzene. Subsequent to the soil-gas survey, five locations with elevated contaminant mass were selected and a passive sampler was deployed at those locations to detect the presence of organic compounds classified as explosives or chemical agents. No explosives or chemical agents were detected above the method detection level, but some compounds were detected below the method detection level but above the nondetection level. Dimethyl disulfide, benzothiazole, chloroacetophenones, and para-chlorophenyl methyl sulfide were all detected below the method detection level but above the nondetection level. The compounds 2,4-dinitrotoluene, and para-chlorophenyl methyl sulfone were detected in samplers but also were detected in trip blanks and are not considered as present in the MCTA. The same five locations that were selected for sampling of explosives and chemical agents were selected for soil sampling. Metal concentrations in composite soil samples collected at five locations from land surface to a depth of 6 inches did not exceed the U.S. Environmental Protection Agency Regional Screening Levels for Industrial Soil. Concentrations in some compounds were higher than the South Carolina Department of Health and Environmental Control background levels for nearby South Carolina, including aluminum, arsenic, barium, beryllium, chromium, copper, iron, lead, manganese, nickel, and potassium. A surface-water sample was collected from McCoys Creek and analyzed for volatile organic compounds, semivolatile organic compounds, and inorganic compounds (metals). No volatile organic compounds and (or) semivolatile organic compounds were detected at levels above the maximum contaminant level of the U.S. Environmental Protection Agency (USEPA) National Primary Drinking Water Standard, and no inorganic compounds exceeded the maximum contaminant level of the USEPA National Primary Drinking Water Standard or the Georgia In-Stream Water-Quality Standard. Iron was the only inorganic compound detected in the surface-water sample (578 micrograms per liter) that exceeded the USEPA National Secondary Drinking Water Standard of 300 micrograms per liter.

  13. White HDPE bottles as source of serious contamination of water samples with Ba and Zn.

    PubMed

    Reimann, Clemens; Grimstvedt, Andreas; Frengstad, Bjørn; Finne, Tor Erik

    2007-03-15

    During a recent study of surface water quality factory new white high-density polyethylene (HDPE) bottles were used for collecting the water samples. According to the established field protocol of the Geological Survey of Norway the bottles were twice carefully rinsed with water in the field prior to sampling. Several blank samples using milli-Q (ELGA) water (>18.2 MOmega) were also prepared. On checking the analytical results the blanks returned values of Ag, Ba, Sr, V, Zn and Zr. For Ba and Zn the values (c. 300 microg/l and 95 microg/l) were about 10 times above the concentrations that can be expected in natural waters. A laboratory test of the bottles demonstrated that the bottles contaminate the samples with significant amounts of Ba and Zn and some Sr. Simple acid washing of the bottles prior to use did not solve the contamination problem for Ba and Zn. The results suggest that there may exist "clean" and "dirty" HDPE bottles depending on manufacturer/production process. When collecting water samples it is mandatory to check bottles regularly as a possible source of contamination.

  14. [Effect of Radix euphorbiae pekinensis extract on bioavailability of paclitaxel after their oral co-administration].

    PubMed

    Li, Minghua; Peng, Li; Yang, Fuheng; Liu, Sijia; Wang, Shengqi

    2015-06-01

    To evaluate the effect of Radix euphorbiae pekinensis extract on the permeability and bioavailability of paclitaxel co-administered orally. Based on Ussing Chamber and in vivo experiment, the permeability and bioavailability of paclitaxel were evaluated after oral co-administration with radix euphorbiae pekinensis in rats. The contents of paclitaxel in the permeates and the blood samples were determined using HPLC and LC-MS/MS method, respectively. In Radix euphorbiae pekinensis co-administration group, the Papp of the mucosal-to-serosal (M-S) transport or serosal-to-mucosal transport (S-M) of paclitaxel in the jejunum or ileum segment differed significantly from those in verapamil co-administration group and blank control group (P<0.05), but the Papp of S-M transport in the colon showed no significant difference from that in the blank control group. In the blank group, the average absolute bioavailability (AB%) of orally administered paclitaxel was only 2.81%, compared to that of 7.63% in radix euphorbiae pekinensis group. The average AB% in verapamil group was about 1.5 times that of the blank group. Co-administration of Radix euphorbiae pekinensis extract can increase the bioavailability of orally administered paclitaxel.

  15. Determination of Natural 14C Abundances in Dissolved Organic Carbon in Organic-Rich Marine Sediment Porewaters by Thermal Sulfate Reduction

    NASA Astrophysics Data System (ADS)

    Johnson, L.; Komada, T.

    2010-12-01

    The abundances of natural 14C in dissolved organic carbon (DOC) in the marine environment hold clues regarding the processes that influence the biogeochemical cycling of this large carbon reservoir. At present, UV irradiation is the widely accepted method for oxidizing seawater DOC for determination of their 14C abundances. This technique yields precise and accurate values with low blanks, but it requires a dedicated vacuum line, and hence can be difficult to implement. As an alternative technique that can be conducted on a standard preparatory vacuum line, we modified and tested a thermal sulfate reduction method that was previously developed to determine δ13C values of marine DOC (Fry B. et al., 1996. Analysis of marine DOC using a dry combustion method. Mar. Chem., 54: 191-201.) to determine the 14C abundances of DOC in marine sediment porewaters. In this method, the sample is dried in a 100 ml round-bottom Pyrex flask in the presence of excess oxidant (K2SO4) and acid (H3PO4), and combusted at 550 deg.C. The combustion products are cryogenically processed to collect and quantify CO2 using standard procedures. Materials we have oxidized to date range from 6-24 ml in volume, and 95-1500 μgC in size. The oxidation efficiency of this method was tested by processing known amounts of reagent-grade dextrose and sucrose (as examples of labile organic matter), tannic acid and humic acid (as examples of complex natural organic matter), and porewater DOC extracted from organic-rich nearshore sediments. The carbon yields for all of these materials averaged 99±4% (n=18). The 14C abundances of standard materials IAEA C-6 and IAEA C-5 processed by this method using >1mgC aliquots were within error of certified values. The size and the isotopic value of the blank were determined by a standard dilution technique using IAEA C-6 and IAEA C-5 that ranged in size from 150 to 1500 μgC (n=4 and 2, respectively). This yielded a blank size of 6.7±0.7 μgC, and a blank isotopic value of 0.54±0.05 fMC. The size of the blank agreed well with that determined directly by processing variable volumes of UV-irradiated deionized water (5.6±0.7 μgC, n=9). The size of the blank amounts to <~5% of the size of porewater DOC samples that are typically recovered from organic-rich sediment cores (~100-500 μgC). The fMC value of the blank suggests that there may be multiple sources of extraneous carbon that range in 14C abundance. In order to assess the fidelity of 14C abundances in natural porewater DOC oxidized by thermal sulfate reduction, we oxidized porewater DOC samples collected from the central floor of the Santa Monica Basin, California Borderland, using both this method and UV irradiation (the latter carried out at the Druffel laboratory, University of California Irvine). The fMC values obtained by the two methods agreed within error. Carbon yields from the two methods also agreed closely. These findings show that thermal sulfate reduction may be a promising method to oxidize small, concentrated marine DOC samples for 14C analysis.

  16. Status report: Implementation of gas measurements at the MAMS 14C AMS facility in Mannheim, Germany

    NASA Astrophysics Data System (ADS)

    Hoffmann, Helene; Friedrich, Ronny; Kromer, Bernd; Fahrni, Simon

    2017-11-01

    By implementing a Gas Interface System (GIS), CO2 gas measurements for radiocarbon dating of small environmental samples (<100 μgC) have been established at the MICADAS (Mini Carbon Dating System) AMS instrument in Mannheim, Germany. The system performance has been optimized and tested with respect to stability and ion yield by repeated blank and standard measurements for sample sizes down to 3 μgC. The highest 12C- low-energy (LE) ion currents, typically reaching 8-15 μA, could be achieved for a mixing ratio of 4% CO2 in Helium, resulting in relative counting errors of 1-2% for samples larger than 10 μgC and 3-7% for sample sizes below 10 μgC. The average count rate was ca. 500 counts per microgram C for OxII standard material. The blank is on the order of 35,000-40,000 radiocarbon years, which is comparable to similar systems. The complete setup thus enables reliable dating for most environmental samples (>3 μgC).

  17. Method and apparatus for inspecting an EUV mask blank

    DOEpatents

    Goldberg, Kenneth A.

    2005-11-08

    An apparatus and method for at-wavelength EUV mask-blank characterization for inspection of moderate and low spatial frequency coating uniformity using a synchrotron or other source of EUV light. The apparatus provides for rapid, non-destruction, non-contact, at-wavelength qualification of large mask areas, and can be self-calibrating or be calibrated to well-characterized reference samples. It can further check for spatial variation of mask reflectivity or for global differences among masks. The apparatus and method is particularly suited for inspection of coating uniformity and quality and can detect defects in the order of 50 .mu.m and above.

  18. Methods to assess carbonaceous aerosol sampling artifacts for IMPROVE and other long-term networks.

    PubMed

    Watson, John G; Chow, Judith C; Chen, L W Antony; Frank, Neil H

    2009-08-01

    Volatile organic compounds (VOCs) and semi-volatile organic compounds (SVOCs) adsorb to quartz fiber filters during fine and coarse particulate matter (PM2.5 and PM10, respectively) sampling for thermal/optical carbon analysis that measures organic carbon (OC) and elemental carbon (EC). Particulate SVOCs can evaporate after collection, with a small portion adsorbed within the filter. Adsorbed organic gases are measured as particulate OC, so passive field blanks, backup filters, prefilter organic denuders, and regression methods have been applied to compensate for positive OC artifacts in several long-term chemical speciation networks. Average backup filter OC levels from the Interagency Monitoring of Protected Visual Environments (IMPROVE) network were approximately 19% higher than field blank values. This difference is within the standard deviation of the average and likely results from low SVOC concentrations in the rural to remote environments of most IMPROVE sites. Backup filters from an urban (Fort Meade, MD) site showed twice the OC levels of field blanks. Sectioning backup filters from top to bottom showed nonuniform OC densities within the filter, contrary to the assumption that VOCs and SVOCs on a backup filter equal those on the front filter. This nonuniformity may be partially explained by evaporation and readsorption of vapors in different parts of the front and backup quartz fiber filter owing to temperature, relative humidity, and ambient concentration changes throughout a 24-hr sample duration. OC-PM2.5 regression analysis and organic denuder approaches demonstrate negative sampling artifact from both Teflon membrane and quartz fiber filters.

  19. Tailor-welded blanks and their production

    NASA Astrophysics Data System (ADS)

    Yan, Qi

    2005-01-01

    Tailor welded blanks had been widely used in the automobile industry. A tailor welded blank consists of several flat sheets that were laser welded together before stamping. A combination of different materials, thickness, and coatings could be welded together to form a blank for stamping car body panels. As for the material for automobile industry, this technology was one of the development trend for automobile industry because of its weight reduction, safety improvement and economical use of materials. In this paper, the characters and production of tailor welded blanks in the market were discussed in detail. There had two major methods to produce tailor welded blanks. Laser welding would replace mesh seam welding for the production of tailor welded blanks in the future. The requirements on the edge preparation of unwelded blanks for tailor welded blanks were higher than the other steel processing technology. In order to produce the laser welded blank, there had the other process before the laser welding in the factory. In the world, there had three kinds of patterns for the large volume production of tailor welded blanks. In China, steel factory played the important role in the promotion of the application of tailor welded blanks. The competition for the supply of tailor welded blanks to the automobile industry would become fierce in the near future. As a result, the demand for the quality control on the production of tailor welded blanks would be the first priority concern for the factory.

  20. 21 CFR 177.1950 - Vinyl chloride-ethylene copolymers.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... deciliter per gram as determined by ASTM method D1243-79, “Standard Test Method for Dilute Solution... vinyl chloride-ethylene copol-ymer per 100 grams of sample tested as determined from the organic... using duplicate blanks. Approximately 400 grams of sample (accurately weighed) shall be placed in a 2...

  1. 21 CFR 177.1950 - Vinyl chloride-ethylene copolymers.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... deciliter per gram as determined by ASTM method D1243-79, “Standard Test Method for Dilute Solution... vinyl chloride-ethylene copol-ymer per 100 grams of sample tested as determined from the organic... using duplicate blanks. Approximately 400 grams of sample (accurately weighed) shall be placed in a 2...

  2. Imaging Gallium Nitride High Electron Mobility Transistors to Identify Point Defects

    DTIC Science & Technology

    2014-03-01

    streamline the sample preparation procedure to maximize the yield of successful samples to be analyzed chemically in an energy dispersive spectrometry...transmission electron microscope (STEM), sample preparation 15. NUMBER OF PAGES 103 16. PRICE CODE 17. SECURITY CLASSIFICATION OF REPORT...Computer Engineering iii THIS PAGE INTENTIONALLY LEFT BLANK iv ABSTRACT The purpose of this thesis is to streamline the sample preparation

  3. Characterizing the Constitutive Properties of AA7075 for Hot Forming

    NASA Astrophysics Data System (ADS)

    Omer, K.; Kim, S.; Butcher, C.; Worswick, M.

    2017-09-01

    The work presented herein investigates the constitutive properties of AA7075 as it undergoes a hot stamping/die quenching process. Tensile specimens were solutionized inside a heated furnace set to 470°C. Once solutionized, the samples were quenched to an intermediate temperature using a vortex air chiller at a minimum rate of 52°C/s. Tensile tests were conducted at steady state temperatures of 470, 400, 300, 200, 115 and 25°C. This solutionizing and subsequent quenching process replicated the temperature cycle and quench rates representative of a die quenching operation. The results of the tensile test were analyzed with digital imaging correlation using an area reduction approach. The area reduction approach approximated the cross-sectional area of the tensile specimen as it necked. The approach allowed for the true stress-strain response to be calculated well past the initial necking point. The resulting true stress-strain curves showed that the AA7075 samples experienced almost no hardening at 470°C. As steady state temperature decreased, the rate of hardening as well as overall material strength increased. The true stress strain curves were fit to a modified version of the extended Voce constitutive model. The resulting fits can be used in a finite element model to predict the behaviour of an AA7075 blank during a die quenching operation.

  4. Summary of chemical data from onsite and laboratory analyses of groundwater samples from the surficial aquifer, Las Vegas, Nevada, April and August 1993 and September 1994

    USGS Publications Warehouse

    Reddy, Michael M.; Gunther, Charmaine D.

    2012-01-01

    Samples were collected from groundwater wells in and about the city of Las Vegas, Nevada, and were analyzed for selected major, minor and trace constituents. Analyses of blank and reference samples are summarized as mean and standard deviation values for all positive results.

  5. Hydrologic and water-quality data related to the occurrence of arsenic for areas along the Madison and Upper Missouri Rivers, southwestern and west-central Montana

    USGS Publications Warehouse

    Tuck, L.K.; Dutton, D.M.; Nimick, D.A.

    1997-01-01

    Geothermal waters in Yellowstone National Park contribute large quantities of arsenic to the headwaters of the Madison River. Water in some Quaternary and Tertiary valley-fill deposits along the Madison and upper Missouri Rivers also is locally enriched in arsenic. Arsenic in surface and ground water in these valleys is an important public- health concern because arsenic concentrations frequently exceed the State of Montana water- quality human health standard of 18 micrograms per liter as well as the U.S. Environmental Protection Agency Maximum Contaminant Level of 50 micrograms per liter. This report presents hydrologic and water-quality data for the Madison and upper Missouri Rivers and selected tributaries, irrigation supply canals or ditches, drains, springs and seeps, for Lake Helena, and for ground water in adjacent areas. Hydrologic and water-quality data were collected and compiled to provide information to more fully understand the extent, magnitude, and source of arsenic in surface and ground water along the Madison and upper Missouri Rivers; to assess, to the extent possible, the mechanisms that control arsenic concentrations; and to assess the effect of irrigation on arsenic concentrations. Hydrologic and arsenic- concentration data were collected by the U.S. Geological Survey and other agencies for 104 surface-water sites and 273 ground-water sites during this and previous studies. The quality of analytical results for arsenic concentrations was evaluated by quality-control samples that were submitted from the field and analyzed in the laboratory with routing samples. Quality-control samples consisted of replicates, standard reference samples, interlaboratory comparison samples, and field blanks.

  6. Investigation of a systematic offset in the measurement of organic carbon with a semicontinuous analyzer.

    PubMed

    Offenberg, John H; Lewandowski, Michael; Edney, Edward O; Kleindienst, Tadeusz E; Jaoui, Mohammed

    2007-05-01

    Organic carbon (OC) was measured semicontinuously in laboratory experiments of steady-state secondary organic aerosol formed by hydrocarbon + nitrogen oxide irradiations. Examination of the mass of carbon measured on the filter for various sample volumes reveals a systematic offset that is not observed when performing an instrumental blank. These findings suggest that simple subtraction of instrumental blanks determined as the standard analysis without sample collection (i.e., by cycling the pump and valves yet filtering zero liters of air followed by routine chemical analysis) from measured concentrations may be inadequate. This may be especially true for samples collected through the filtration of small air volumes wherein the influence of the systematic offset is greatest. All of the experiments show that filtering a larger volume of air minimizes the influence of contributions from the systematic offset. Application of these results to measurements of ambient concentrations of carbonaceous aerosol suggests a need for collection of sufficient carbon mass to minimize the relative influence of the offset signal.

  7. 40 CFR 53.58 - Operational field precision and blank test.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... samplers are also subject to a test for possible deposition of particulate matter on inactive filters... deposition is defined as the mass of material inadvertently deposited on a sample filter that is stored in a... electrical power to accommodate three test samplers are required. (2) Teflon sample filters, as specified in...

  8. Design and Optimization of the SPOT Primary Mirror Segment

    NASA Technical Reports Server (NTRS)

    Budinoff, Jason G.; Michaels, Gregory J.

    2005-01-01

    The 3m Spherical Primary Optical Telescope (SPOT) will utilize a single ring of 0.86111 point-to-point hexagonal mirror segments. The f2.85 spherical mirror blanks will be fabricated by the same replication process used for mass-produced commercial telescope mirrors. Diffraction-limited phasing will require segment-to-segment radius of curvature (ROC) variation of approx.1 micron. Low-cost, replicated segment ROC variations are estimated to be almost 1 mm, necessitating a method for segment ROC adjustment & matching. A mechanical architecture has been designed that allows segment ROC to be adjusted up to 400 microns while introducing a minimum figure error, allowing segment-to-segment ROC matching. A key feature of the architecture is the unique back profile of the mirror segments. The back profile of the mirror was developed with shape optimization in MSC.Nastran(TradeMark) using optical performance response equations written with SigFit. A candidate back profile was generated which minimized ROC-adjustment-induced surface error while meeting the constraints imposed by the fabrication method. Keywords: optimization, radius of curvature, Pyrex spherical mirror, Sigfit

  9. Retro-dimension-cue benefit in visual working memory.

    PubMed

    Ye, Chaoxiong; Hu, Zhonghua; Ristaniemi, Tapani; Gendron, Maria; Liu, Qiang

    2016-10-24

    In visual working memory (VWM) tasks, participants' performance can be improved by a retro-object-cue. However, previous studies have not investigated whether participants' performance can also be improved by a retro-dimension-cue. Three experiments investigated this issue. We used a recall task with a retro-dimension-cue in all experiments. In Experiment 1, we found benefits from retro-dimension-cues compared to neutral cues. This retro-dimension-cue benefit is reflected in an increased probability of reporting the target, but not in the probability of reporting the non-target, as well as increased precision with which this item is remembered. Experiment 2 replicated the retro-dimension-cue benefit and showed that the length of the blank interval after the cue disappeared did not influence recall performance. Experiment 3 replicated the results of Experiment 2 with a lower memory load. Our studies provide evidence that there is a robust retro-dimension-cue benefit in VWM. Participants can use internal attention to flexibly allocate cognitive resources to a particular dimension of memory representations. The results also support the feature-based storing hypothesis.

  10. Retro-dimension-cue benefit in visual working memory

    PubMed Central

    Ye, Chaoxiong; Hu, Zhonghua; Ristaniemi, Tapani; Gendron, Maria; Liu, Qiang

    2016-01-01

    In visual working memory (VWM) tasks, participants’ performance can be improved by a retro-object-cue. However, previous studies have not investigated whether participants’ performance can also be improved by a retro-dimension-cue. Three experiments investigated this issue. We used a recall task with a retro-dimension-cue in all experiments. In Experiment 1, we found benefits from retro-dimension-cues compared to neutral cues. This retro-dimension-cue benefit is reflected in an increased probability of reporting the target, but not in the probability of reporting the non-target, as well as increased precision with which this item is remembered. Experiment 2 replicated the retro-dimension-cue benefit and showed that the length of the blank interval after the cue disappeared did not influence recall performance. Experiment 3 replicated the results of Experiment 2 with a lower memory load. Our studies provide evidence that there is a robust retro-dimension-cue benefit in VWM. Participants can use internal attention to flexibly allocate cognitive resources to a particular dimension of memory representations. The results also support the feature-based storing hypothesis. PMID:27774983

  11. Quality-assurance design applied to an assessment of agricultural pesticides in ground water from carbonate bedrock aquifers in the Great Valley of eastern Pennsylvania

    USGS Publications Warehouse

    Breen, Kevin J.

    2000-01-01

    Assessments to determine whether agricultural pesticides are present in ground water are performed by the Commonwealth of Pennsylvania under the aquifer monitoring provisions of the State Pesticides and Ground Water Strategy. Pennsylvania's Department of Agriculture conducts the monitoring and collects samples; the Department of Environmental Protection (PaDEP) Laboratory analyzes the samples to measure pesticide concentration. To evaluate the quality of the measurements of pesticide concentration for a groundwater assessment, a quality-assurance design was developed and applied to a selected assessment area in Pennsylvania. This report describes the quality-assurance design, describes how and where the design was applied, describes procedures used to collect and analyze samples and to evaluate the results, and summarizes the quality assurance results along with the assessment results.The design was applied in an agricultural area of the Delaware River Basin in Berks, Lebanon, Lehigh, and Northampton Counties to evaluate the bias and variability in laboratory results for pesticides. The design—with random spatial and temporal components—included four data-quality objectives for bias and variability. The spatial design was primary and represented an area comprising 30 sampling cells. A quality-assurance sampling frequency of 20 percent of cells was selected to ensure a sample number of five or more for analysis. Quality-control samples included blanks, spikes, and replicates of laboratory water and spikes, replicates, and 2-lab splits of groundwater. Two analytical laboratories, the PaDEP Laboratory and a U.S. Geological Survey Laboratory, were part of the design. Bias and variability were evaluated by use of data collected from October 1997 through January 1998 for alachlor, atrazine, cyanazine, metolachlor, simazine, pendimethalin, metribuzin, and chlorpyrifos.Results of analyses of field blanks indicate that collection, processing, transport, and laboratory analysis procedures did not contaminate the samples; there were no false-positive results. Pesticides were detected in water when pesticides were spiked into (added to) samples. There were no false negatives for the eight pesticides in all spiked samples. Negative bias was characteristic of analytical results for the eight pesticides, and bias was generally in excess of 10 percent from the ‘true’ or expected concentration (34 of 39 analyses, or 87 percent of the ground-water results) for pesticide concentrations ranging from 0.31 to 0.51 mg/L (micrograms per liter). The magnitude of the negative bias for the eight pesticides, with the exception of cyanazine, would result in reported concentrations commonly 75-80 percent of the expected concentration in the water sample. The bias for cyanazine was negative and within 10 percent of the expected concentration. A comparison of spiked pesticide-concentration recoveries in laboratory water and ground water indicated no effect of the ground-water matrix, and matrix interference was not a source of the negative bias. Results for the laboratory-water spikes submitted in triplicate showed large variability for recoveries of atrazine, cyanazine, and pendimethalin. The relative standard deviation (RSD) was used as a measure of method variability over the course of the study for laboratory waters at a concentration of 0.4 mg/L. An RSD of about 11 percent (or about ?0.05 mg/L)characterizes the method results for alachlor, chlorpyrifos, metolachlor, metribuzin, and simazine. Atrazine and pendimethalin have RSD values of about 17 and 23 percent, respectively. Cyanazine showed the largest RSD at nearly 51 percent. The pesticides with low variability in laboratory-water spikes also had low variability in ground water.The assessment results showed that atrazinewas the most commonly detected pesticide in ground water in the assessment area. Atrazine was detected in water from 22 of the 28 wells sampled, and recovery results for atrazine were some of the worst (largest negative bias). Concentrations of the eight pesticides in ground water from wells were generally less than 0.3 µg/L. Only six individual measurements of the concentrations in water from six of the wells were at or above 0.3 µg/L, five for atrazine and one for metolachlor. There were eight additional detections of metolachlor and simazine at concentrations less than 0.1 µg/L. No well water contained more than one pesticide at concentra-tions at or above 0.3 µg/L. Evidence exists, how-ever, for a pattern of co-occurrence of metolachlor and simazine at low concentrations with higher concentrations of atrazine.Large variability in replicate samples and negative bias for pesticide recovery from spiked samples indicate the need to use data for pesticide recovery in the interpretation of measured pesti-cide concentrations in ground water. Data from samples spiked with known amounts of pesticides were a critical component of a quality-assurance design for the monitoring component of the Pesti-cides and Ground Water Strategy.Trigger concentrations, the concentrations that require action under the Pesticides and Ground Water Strategy, should be considered maximums for action. This consideration is needed because of the magnitude of negative bias.

  12. Development of a method for the determination of Fusarium fungi on corn using mid-infrared spectroscopy with attenuated total reflection and chemometrics.

    PubMed

    Kos, Gregor; Lohninger, Hans; Krska, Rudolf

    2003-03-01

    A novel method, which enables the determination of fungal infection with Fusarium graminearum on corn within minutes, is presented. The ground sample was sieved and the particle size fraction between >250 and 100 microm was used for mid-infrared/attenuated total reflection (ATR) measurements. The sample was pressed onto the ATR crystal, and reproducible pressure was applied. After the spectra were recorded, they were subjected to principle component analysis (PCA) and classified using cluster analysis. Observed changes in the spectra reflected changes in protein, carbohydrate, and lipid contents. Ergosterol (for the total fungal biomass) and the toxin deoxynivalenol (DON; a secondary metabolite) of Fusarium fungi served as reference parameters, because of their relevance for the examination of corn based food and feed. The repeatability was highly improved by sieving prior to recording the spectra, resulting in a better clustering in PCA score/score plots. The developed method enabled the separation of samples with a toxin content of as low as 310 microg/kg from noncontaminated (blank) samples. Investigated concentration ranges were 880-3600 microg/kg for ergosterol and 310-2596 microg/kg for DON. The percentage of correctly classified samples was up to 100% for individual samples compared with a number of blank samples.

  13. Standard-Size Blanks for Furniture and Cabinets

    Treesearch

    Philip A. Araman

    1983-01-01

    Blanks are rough-dimension parts of a specific size which may be solid or glued up; quality depends on the final use of the material. Standard-size blanks are blanks made to standard thicknesses, lengths, and widths for each desired quality. Blanks in a few standard sizes can be used to make the thousands of different size rough-dimension parts needed by a furniture or...

  14. Development of an enzymatic assay to measure lactate in perchloric acid-precipitated cerebrospinal fluid.

    PubMed

    Lu, Jun; Genzen, Jonathan R; Grenache, David G

    2018-04-27

    Individuals with inherited deficiencies of the pyruvate dehydrogenase complex or the respiratory chain complex can have increased concentrations of cerebrospinal fluid (CSF) lactate. Such measurements are clinical useful when measured in conjunction with pyruvate in order to calculate the lactate:pyruvate (L:P) ratio, a useful surrogate of cytosolic redox status. CSF pyruvate is measured in a protein-free supernatant prepared by the addition of CSF to perchloric acid while lactate is measured in untreated CSF. Utilizing the same sample for both lactate and pyruvate measurements is desirable. To develop a method to measure lactate in perchloric-acid precipitated CSF and validate the L:P ratio as calculated from the analysis of both analytes in the same sample. Samples were prepared by the addition of 1 mL CSF to 2 mL 8% (w/v) cold perchloric acid, incubated on ice for 10 min, then centrifuged to obtain a protein-free supernatant. Lactate was measured by its oxidation to pyruvate and hydrogen peroxide using lactate oxidase and the absorbance of the resulting chromogen determined at 540 nm on a Roche cobas c501 chemistry analyzer. Method accuracy, linearity, imprecision and sensitivity were determined and a reference interval was verified. To assess accuracy, this method was compared to lactate determined in unaltered CSF at another laboratory using 41 specimens with lactate concentrations from 0.6-11.9 mmol/L. Linear regression produced a slope of 1.09 and y-intercept of 0.26 (R 2  = 1.00). Recovery was performed by ad-mixes of a high lactate standard and a CSF pool in different ratios to create a set of 19 samples prior to preparing protein-free supernatants. Recovery was 94.6-100% (mean ± SD was 97.4 ± 1.4%) at lactate concentrations of 2.68 to 12.63 mmol/L. Linearity was determined by combining two supernatants with low and high lactate concentrations in different ratios to create a set of six samples (0.15-12.70 mmol/L) that were tested in duplicate. Linear regression generated a slope of 1.01, y-intercept of -0.04 (R 2  = 1.00). Precision was verified by analyzing quality control materials (acid-treated lactate standard) in 3 replicates each day for 5 days. Within-laboratory imprecision was 2.3% at 1.5 mmol/L and 1.5% at 10.5 mmol/L. The limit of blank was 0.05 mmol/L as determined by the mean added to three standard deviations determined from 10 replicates of perchloric-acid treated saline pool. The limit of detection was determined to be 0.12 mmol/L calculated from 10 replicates of a patient sample treated with perchloric-acid. The manufacturer's reference interval of 1.1-2.4 mmol/L was verified using 20 residual patient CSF samples. CSF lactate can be measured with accuracy and precision using the same perchloric-acid treated sample that is used for pyruvate. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Simultaneous determination of 117 pesticides and 30 mycotoxins in raw coffee, without clean-up, by LC-ESI-MS/MS analysis.

    PubMed

    Reichert, Bárbara; de Kok, André; Pizzutti, Ionara Regina; Scholten, Jos; Cardoso, Carmem Dickow; Spanjer, Martien

    2018-04-03

    This paper describes the optimization and validation of an acetonitrile based method for simultaneous extraction of multiple pesticides and mycotoxins from raw coffee beans followed by LC-ESI-MS/MS determination. Before extraction, the raw coffee samples were milled and then slurried with water. The slurried samples were spiked with two separate standard solutions, one containing 131 pesticides and a second with 35 mycotoxins, which were divided into 3 groups of different relative concentration levels. Optimization of the QuEChERS approach included performance tests with acetonitrile acidified with acetic acid or formic acid, with or without buffer and with or without clean-up of the extracts before LC-ESI-MS/MS analysis. For the clean-up step, seven d-SPE sorbents and their various mixtures were evaluated. After method optimization a complete validation study was carried out to ensure adequate performance of the extraction and chromatographic methods. The samples were spiked at 3 concentrations levels with both mycotoxins and pesticides (with 6 replicates at each level, n = 6) and then submitted to the extraction procedure. Before LC-ESI-MS/MS analysis, the acetonitrile extracts were diluted 2-fold with methanol, in order to improve the chromatographic performance of the early-eluting polar analytes. Calibration standard solutions were prepared in organic solvent and in blank coffee extract at 7 concentration levels and analyzed 6 times each. The method was assessed for accuracy (recovery %), precision (RSD%), selectivity, linearity (r 2 ), limit of quantification (LOQ) and matrix effects (%). Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Methylmercury and other chemical constituents in Pacific coastal fog water from seven sites in Central/Northern California (FogNet) during the summer of 2014

    NASA Astrophysics Data System (ADS)

    Weiss-Penzias, P. S.; Heim, W. A.; Fernandez, D.; Coale, K. H.; Oliphant, A. J.; Dann, D.; Porter, M.; Hoskins, D.; Dodge, C.

    2014-12-01

    This project investigates the mercury content in summertime Pacific coastal fog in California and whether fog could be an important vector for ocean emissions of mercury to be deposited via fog drip to upland coastal ecosystems. Efforts began in early 2014 with the building of 7 active-strand fog collectors based on the Colorado State University Caltech CASCC design. The new UCSC CASCC includes doors sealing the collector which open under microcomputer control based on environmental sensing (relative humidity). Seven sites spanning from Trinidad in the north to Marina in the south have collected samples June-August 2014 under a project called FogNet. Fog conditions were favorable for collecting large water volumes (> 250 mL) at many sites. Fog samplers were cleaned with soap and deionized water daily and field blanks taken immediately following cleaning. Fog water samples were collected overnight, split into an aliquot for anion and DOC/DIC analysis and the remaining sample was acidified. Monomethyl mercury (MMHg) concentrations in samples and field blanks for 3 sites in FogNet are shown in the accompanying figure. The range of MMHg concentrations from 10 fog water samples > 100 mL in volume was 0.9-9.3 ng/L (4.5-46.4 pM). Elevated MMHg concentrations (> 5 ng/L, 25 pM) were observed at 2 sites: UC Santa Cruz and Bodega Bay. The field blanks produced MMHg concentrations of 0.08-0.4 ng/L (0.4-2.0 pM), which was on average < 10% of the sample concentration and suggests the artifact due to sampling was small. The observed MMHg concentrations in fog water observed is this study are 1-2 orders of magnitude greater than MMHg concentrations seen previously in rain water samples from the California coast suggesting an additional source of MMHg to fog. Shipboard measurements of dimethyl mercury (DMHg) in coastal California seawater during the time period of FogNet operations (summer 2014) reveal surface waters that were supersaturated in DMHg which represents a potential source of organic mercury to the overlying fog bank.

  17. Hydrogeologic and chemical data for the O-Field area, Aberdeen Proving Ground, Maryland

    USGS Publications Warehouse

    Nemoff, P.R.; Vroblesky, D.A.

    1989-01-01

    O-Field, located at the Edgewood area of Aberdeen Proving Ground , Maryland, was periodically used for disposal of munitions, waste chemicals, and chemical-warfare agents from World War II through the 1950' s. This report includes various physical, geologic, chemical, and hydrologic data obtained from well-core, groundwater, surface water, and bottom-sediment sampling sites at and near the O-Field disposal area. The data are presented in tables and hydrographs. Three site-location maps are also included. Well-core data include lithologic logs for 11 well- cluster sites, grain-size distributions, various chemical characteristics, and confining unit characteristics. Groundwater data include groundwater chemistry, method blanks for volatile organic carbon, available data on volatile and base/neutral organics, and compilation of corresponding method blanks, chemical-warfare agents, explosive-related products, radionuclides, herbicides, and groundwater levels. Surface-water data include field-measured characteristics; concentrations of various inorganic constituents including arsenic; selected organic constituents with method blanks; detection limits of organics; and a compilation of information on corresponding acids, volatiles, and semivolatiles. Bottom- sediment data include inorganic properties and constituents; organic chemistry; detection limits for organic chemicals; a compilation of information on acids, volatiles, and semivolatiles; and method blanks corresponding to acids, volatiles, and semivolatiles. A set of 15 water- level hydrographs for the period March 1986 through September 1987 also is included in the report. (USGS)

  18. Detection of diethylene glycol adulteration in propylene glycol--method validation through a multi-instrument collaborative study.

    PubMed

    Li, Xiang; Arzhantsev, Sergey; Kauffman, John F; Spencer, John A

    2011-04-05

    Four portable NIR instruments from the same manufacturer that were nominally identical were programmed with a PLS model for the detection of diethylene glycol (DEG) contamination in propylene glycol (PG)-water mixtures. The model was developed on one spectrometer and used on other units after a calibration transfer procedure that used piecewise direct standardization. Although quantitative results were produced, in practice the instrument interface was programmed to report in Pass/Fail mode. The Pass/Fail determinations were made within 10s and were based on a threshold that passed a blank sample with 95% confidence. The detection limit was then established as the concentration at which a sample would fail with 95% confidence. For a 1% DEG threshold one false negative (Type II) and eight false positive (Type I) errors were found in over 500 samples measured. A representative test set produced standard errors of less than 2%. Since the range of diethylene glycol for economically motivated adulteration (EMA) is expected to be above 1%, the sensitivity of field calibrated portable NIR instruments is sufficient to rapidly screen out potentially problematic materials. Following method development, the instruments were shipped to different sites around the country for a collaborative study with a fixed protocol to be carried out by different analysts. NIR spectra of replicate sets of calibration transfer, system suitability and test samples were all processed with the same chemometric model on multiple instruments to determine the overall analytical precision of the method. The combined results collected for all participants were statistically analyzed to determine a limit of detection (2.0% DEG) and limit of quantitation (6.5%) that can be expected for a method distributed to multiple field laboratories. Published by Elsevier B.V.

  19. Optimization and evaluation of multi-bed adsorbent tube method in collection of volatile organic compounds

    NASA Astrophysics Data System (ADS)

    Ho, Steven Sai Hang; Wang, Liqin; Chow, Judith C.; Watson, John G.; Xue, Yonggang; Huang, Yu; Qu, Linli; Li, Bowei; Dai, Wenting; Li, Lijuan; Cao, Junji

    2018-04-01

    The feasibility of using adsorbent tubes to collect volatile organic compounds (VOCs) has been demonstrated since the 1990's and standardized as Compendium Method TO-17 by the U.S. Environmental Protection Agency (U.S EPA). This paper investigates sampling and analytical variables on concentrations of 57 ozone (O3) precursors (C2-C12 aliphatic and aromatic VOCs) specified for the Photochemical Assessment Monitoring Station (PAMS). Laboratory and field tests examined multi-bed adsorbent tubes containing a sorbate combination of Tenax TA, Carbograph 1 TD, and Carboxen 1003. Analyte stabilities were influenced by both collection tube temperature and ambient O3 concentrations. Analytes degraded during storage, while blank levels were elevated by passive adsorption. Adsorbent tube storage under cold temperatures (- 10 °C) in a preservation container filled with solid silica gel and anhydrous calcium sulfate (CaSO4) ensured sample integrity. A high efficiency (> 99%) O3 scrubber (i.e., copper coil tube filled with saturated potassium iodide [KI]) removed O3 (i.e., < 200 ppbv) from the air stream with a sampling capacity of 30 h. Water vapor scrubbers interfered with VOC measurements. The optimal thermal desorption-gas chromatography/mass spectrometry (TD-GC/MS) desorption time of 8 min was found at 330 °C. Good linearity (R2 > 0.995) was achieved for individual analyte calibrations (with the exception of acetylene) for mixing ratios of 0.08-1.96 ppbv. The method detection limits (MDLs) were below 0.055 ppbv for a 3 L sample volume. Replicate analyses showed relative standard deviations (RSDs) of < 10%, with the majority of the analytes within < 5%.

  20. Analysis of Marine Biota for Chemical Warfare Materials by Means of a Gas Chromatography/Mass Spectrometer System

    DTIC Science & Technology

    2011-01-01

    All of the samples were analyzed in SIM. By comparing the EIC’s (See Appendix) of the MS (for sample EML 091524) and Sample EML091524 it can be...of detection. 25 Blank 26 ACRONYMS amu BFB BME CCV CTC CTF CVAA CVAO CWM DoD ECBC EIC EICP EML EPA GC HD HUMMA IB ICV IOP L

  1. Use of an ultra-clean sampling technique with inductively coupled plasma-mass spectrometry to determine trace-element concentrations in water from the Kirkwood-Cohansey Aquifer system, coastal plain, New Jersey

    USGS Publications Warehouse

    Ivahnenko, Tamara; Szabo, Zoltan; Hall, G.S.

    1996-01-01

    Water samples were collected during 1993 from 22 public supply wells screened in the Kirkwood-Cohansey aquifer system; concentrations of 18 trace elements were determined primarily by using inductively coupled plasma-mass spectrometry (ICP-MS) techniques, though graphite furnace atomic adsorption, hydride generation, and cold- vapor flameless atomic adsorption techniques were used for thallium, arsenic, and mercury, respectively, at the U.S. Geological Survey (USGS) National Water Quality Laboratory (NWQL). In addition, laboratory measurements of alkalinity and turbidity were made. The ground-water samples were collected by using ultra-clean sampling protocols developed by the USGS for collecting ground-water samples in areas with water containing low concentrations of trace elements. This technique is based on recently gained experience in sampling surface water for these elements. Field parameters (water temperature, specific conductance, pH, and dissolved-oxygen concentration) were monitored prior to sample collection. Three equipment blanks were collected to ensure that low-level trace-element contamination did not occur during sample collection. One split sample and a commercially- prepared reference standard were submitted to the NWQL o evaluate laboratory precision and accuracy, respectively. Trace-element concentrations in 10 sample splits and one equipment blank were also determined at the Rutgers University Chemistry Department laboratory. Results of the ICP-MS analyses and cold vapor flameless atomic absorption indicated that five trace elements-- cobalt, copper, lead, mercury, and nickel--were detectable in low concentrations (<0.1-29 mg/L) in most of the samples from the 22 wells, and four elements--aluminum, barium, manganese and zinc--were detected in higher concentrations than the other elements (30-710 mg/L for aluminum; 4-180 mg/L for barium, manganese, and zinc). The remaining nine trace elements were present in concentrations consistently lower than the minimum reporting limit. Turbidity was low (less than 1 nephelometric turbidity unit (NTU)), indicating that the trace-element concentrations were present in the dissolved phase and ideally would be reproducible in the absence of highly variable concentrations of particulates. The concentration of lead in one sample exceeded the U.S. Environmental Protection Agency (USEPA) action level of 15 mg/L; concentrations ranged from <1 to 16 mg/L. Mercury was frequently detected; concentrations ranged from <0.1 to 1.1 mg/L but did not exceed the USEPA maximum contaminant level. Results of analyses of the equipment blanks indicated that samples collected by using the new ultra-clean sampling protocols were free of low-level (< 1mg/L) trace-element contamination. The analysis of the split sample sent to the NWQL had a difference of 5 percent or less for all constituents except aluminum, for which the analysis had a difference of 10 percent. Results of ICP-MS analyses of split water samples sent to the Rutgers University Chemistry Department laboratory were, in general, in good agreement (within 10 percent) with those of the NWQL. Results of the analysis of the commercial standard agreed (within 5 percent) with the known concentrations of the trace elements. The quality-assurance data (three blanks, one split sample, and one standard), although not statistically evaluated because of the small data set, indicate that the measured trace-element concentrations are precise and accurate and that the samples were free of contamination at the microgram-per-liter level of contamination.

  2. Variance Estimation Using Replication Methods in Structural Equation Modeling with Complex Sample Data

    ERIC Educational Resources Information Center

    Stapleton, Laura M.

    2008-01-01

    This article discusses replication sampling variance estimation techniques that are often applied in analyses using data from complex sampling designs: jackknife repeated replication, balanced repeated replication, and bootstrapping. These techniques are used with traditional analyses such as regression, but are currently not used with structural…

  3. 7 CFR 201.35 - Blank spaces.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Blank spaces. 201.35 Section 201.35 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... REGULATIONS Labeling in General § 201.35 Blank spaces. Blank spaces on the label shall be deemed to imply the...

  4. 7 CFR 201.35 - Blank spaces.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Blank spaces. 201.35 Section 201.35 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... REGULATIONS Labeling in General § 201.35 Blank spaces. Blank spaces on the label shall be deemed to imply the...

  5. 7 CFR 201.35 - Blank spaces.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Blank spaces. 201.35 Section 201.35 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... REGULATIONS Labeling in General § 201.35 Blank spaces. Blank spaces on the label shall be deemed to imply the...

  6. 7 CFR 201.35 - Blank spaces.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Blank spaces. 201.35 Section 201.35 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... REGULATIONS Labeling in General § 201.35 Blank spaces. Blank spaces on the label shall be deemed to imply the...

  7. 7 CFR 201.35 - Blank spaces.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Blank spaces. 201.35 Section 201.35 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... REGULATIONS Labeling in General § 201.35 Blank spaces. Blank spaces on the label shall be deemed to imply the...

  8. 40 CFR Appendix B to Part 136 - Definition and Procedure for the Determination of the Method Detection Limit-Revision 1.11

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... that the analyte concentration is greater than zero and is determined from analysis of a sample in a given matrix containing the analyte. Scope and Application This procedure is designed for applicability to a wide variety of sample types ranging from reagent (blank) water containing analyte to wastewater...

  9. 40 CFR Appendix B to Part 136 - Definition and Procedure for the Determination of the Method Detection Limit-Revision 1.11

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... that the analyte concentration is greater than zero and is determined from analysis of a sample in a given matrix containing the analyte. Scope and Application This procedure is designed for applicability to a wide variety of sample types ranging from reagent (blank) water containing analyte to wastewater...

  10. 40 CFR Appendix B to Part 136 - Definition and Procedure for the Determination of the Method Detection Limit-Revision 1.11

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... that the analyte concentration is greater than zero and is determined from analysis of a sample in a given matrix containing the analyte. Scope and Application This procedure is designed for applicability to a wide variety of sample types ranging from reagent (blank) water containing analyte to wastewater...

  11. [Evaluation of the AOAC 985.29 enzimic gravimetric method for determination of dietary fiber in oat and corn grains].

    PubMed

    da Silva, Leila Picolli; Ciocca, Maria de Lourdes Santorio; Furlong, Eliana Badiale

    2003-12-01

    The precision attributes and use of the enzymatic-gravimetric method of Prosky et al. (1992) (AOAC 985.29) were evaluated using corn (BR 5202 Pampa) and oat (UFRGS 15) samples. The effect of laboratory batches carried out in different days were evaluated in six laboratory batches, using for each material one duplicate for total fiber (FT) determination, one duplicate for insoluble fiber (FI) determination and blank ones for FT and for FI (both in duplicate). In order to characterize repetitive aspects, five other FT and FI determinations added to each sample were evaluated, summing up 11 data. The low coefficients of variation in the first six batches were considered acceptable as an expression of expected total intralaboratory variation. The repetitive of the method was considered good for FT determinations (CVs < 10%). However, in the FI determination a high frequency of negative values of ash and blanks was found, impairing the repetitive aspects evaluation. The magnitude of the total gravimetric corrections varies with the kind of the sample and is especially influenced by the protein content.

  12. [Prospects of the integration of dry blood spot technology with human health and environmental population studies].

    PubMed

    Pomelova, V G; Osin, N S

    2007-01-01

    This literature review is dedicated to prospects of the use of whole blood dried on special filter paper as a source of biological material for human health and environmental population studies. Evident advantages of this low-invasive approach include the following: it is easy to take a blood sample from a patient's finger ofa neonate's heel; the cost of sampling as well as transportation and storage of samples is low; paper blanks are safe to manipulate with and convenient to mail in sealed plastic packages. Many analytes, such as DNA, become more stable after drying, which allows for the detection of phenotypic and genotypic markers, as well as multiple gene mutations by multiplex DNA amplification. Modern diagnostic techniques make it possible to detect a wide spectrum of biomarkers characterizing the condition of the endocrine, cardiovascular, reproductive, and immune systems of the organism in a single drop of blood. This allows considering paper blanks with dry blood the key component of multilevel interdisciplinary population studies on neonatal screening, disease spread surveillance, seroepidemiological monitoring, and ecological and genetic research.

  13. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--QA ANALYTICAL RESULTS FOR METALS IN REPLICATE SAMPLES

    EPA Science Inventory

    The Metals in Replicate Samples data set contains the analytical results of measurements of up to 2 metals in 172 replicate (duplicate) samples from 86 households. Measurements were made in samples of blood. Duplicate samples for a small percentage of the total number of sample...

  14. Optimization and validation of liquid chromatography and headspace-gas chromatography based methods for the quantitative determination of capsaicinoids, salicylic acid, glycol monosalicylate, methyl salicylate, ethyl salicylate, camphor and l-menthol in a topical formulation.

    PubMed

    Pauwels, Jochen; D'Autry, Ward; Van den Bossche, Larissa; Dewever, Cédric; Forier, Michel; Vandenwaeyenberg, Stephanie; Wolfs, Kris; Hoogmartens, Jos; Van Schepdael, Ann; Adams, Erwin

    2012-02-23

    Capsaicinoids, salicylic acid, methyl and ethyl salicylate, glycol monosalicylate, camphor and l-menthol are widely used in topical formulations to relieve local pain. For each separate compound or simple mixtures, quantitative analysis methods are reported. However, for a mixture containing all above mentioned active compounds, no assay methods were found. Due to the differing physicochemical characteristics, two methods were developed and optimized simultaneously. The non-volatile capsaicinoids, salicylic acid and glycol monosalicylate were analyzed with liquid chromatography following liquid-liquid extraction, whereas the volatile compounds were analyzed with static headspace-gas chromatography. For the latter method, liquid paraffin was selected as compatible dilution solvent. The optimized methods were validated in terms of specificity, linearity, accuracy and precision in a range of 80% to 120% of the expected concentrations. For both methods, peaks were well separated without interference of other compounds. Linear relationships were demonstrated with R² values higher than 0.996 for all compounds. Accuracy was assessed by performing replicate recovery experiments with spiked blank samples. Mean recovery values were all between 98% and 102%. Precision was checked at three levels: system repeatability, method precision and intermediate precision. Both methods were found to be acceptably precise at all three levels. Finally, the method was successfully applied to the analysis of some real samples (cutaneous sticks). Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Quality of nutrient data from streams and ground water sampled during water years 1992-2001

    USGS Publications Warehouse

    Mueller, David K.; Titus, Cindy J.

    2005-01-01

    Proper interpretation of water-quality data requires consideration of the effects that bias and variability might have on measured constituent concentrations. In this report, methods are described to estimate the bias due to contamination of samples in the field or laboratory and the variability due to sample collection, processing, shipment, and analysis. Contamination can adversely affect interpretation of measured concentrations in comparison to standards or criteria. Variability can affect interpretation of small differences between individual measurements or mean concentrations. Contamination and variability are determined for nutrient data from quality-control samples (field blanks and replicates) collected as part of the National Water-Quality Assessment (NAWQA) Program during water years 1992-2001. Statistical methods are used to estimate the likelihood of contamination and variability in all samples. Results are presented for five nutrient analytes from stream samples and four nutrient analytes from ground-water samples. Ammonia contamination can add at least 0.04 milligram per liter in up to 5 percent of all samples. This could account for more than 22 percent of measured concentrations at the low range of aquatic-life criteria (0.18 milligram per liter). Orthophosphate contamination, at least 0.019 milligram per liter in up to 5 percent of all samples, could account for more than 38 percent of measured concentrations at the limit to avoid eutrophication (0.05 milligram per liter). Nitrite-plus-nitrate and Kjeldahl nitrogen contamination is less than 0.4 milligram per liter in 99 percent of all samples; thus there is no significant effect on measured concentrations of environmental significance. Sampling variability has little or no effect on reported concentrations of ammonia, nitrite-plus-nitrate, orthophosphate, or total phosphorus sampled after 1998. The potential errors due to sampling variability are greater for the Kjeldahl nitrogen analytes and for total phosphorus sampled before 1999. The uncertainty in a mean of 10 concentrations caused by sampling variability is within a small range (1 to 7 percent) for all nutrients. These results can be applied to interpretation of environmental data collected during water years 1992-2001 in 52 NAWQA study units.

  16. NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR METALS IN REPLICATE SAMPLES

    EPA Science Inventory

    The Metals in Replicate Samples data set contains the analytical results of measurements of up to 27 metals in 133 replicate (duplicate) samples from 62 households. Measurements were made in samples of soil, blood, tap water, and drinking water. Duplicate samples for a small pe...

  17. Benthic Flux Sampling Device. Operations, Methods, and Procedures

    DTIC Science & Technology

    1993-02-01

    nitric acid (HNO3) overnight, then rinse with D.I. water. When in doubt, consult with the chemist for proper cleaning protocols. CHARGE BATTERIES...sis being performed. The system will be flushed with methanol to remove organic com- pounds and with nitric acid to remove metals. The nitric acid ... acid -washed, 500-me Teflon (TFE) sampling bottles aboard the BFSD. After each deployment, blank ferrules are fitted in place of the sampling lines and

  18. Method of Making Lightweight, Single Crystal Mirror

    NASA Technical Reports Server (NTRS)

    Bly, Vincent T. (Inventor)

    2015-01-01

    A method of making a mirror from a single crystal blank may include fine grinding top and bottom surfaces of the blank to be parallel. The blank may then be heat treated to near its melting temperature. An optical surface may be created on an optical side of the blank. A protector may be bonded to the optical surface. With the protector in place, the blank may be light weighted by grinding a non-optical surface of the blank using computer controlled grinding. The light weighting may include creating a structure having a substantially minimum mass necessary to maintain distortion of the mirror within a preset limit. A damaged layer of the non-optical surface caused by light weighting may be removed with an isotropic etch and/or repaired by heat treatment. If an oxide layer is present, the entire blank may then be etched using, for example, hydrofluoric acid. A reflecting coating may be deposited on the optical surface.

  19. Understanding EUV mask blank surface roughness induced LWR and associated roughness requirement

    NASA Astrophysics Data System (ADS)

    Yan, Pei-Yang; Zhang, Guojing; Gullikson, Eric M.; Goldberg, Ken A.; Benk, Markus P.

    2015-03-01

    Extreme ultraviolet lithography (EUVL) mask multi-layer (ML) blank surface roughness specification historically comes from blank defect inspection tool requirement. Later, new concerns on ML surface roughness induced wafer pattern line width roughness (LWR) arise. In this paper, we have studied wafer level pattern LWR as a function of EUVL mask surface roughness via High-NA Actinic Reticle Review Tool. We found that the blank surface roughness induced LWR at current blank roughness level is in the order of 0.5nm 3σ for NA=0.42 at the best focus. At defocus of ±40nm, the corresponding LWR will be 0.2nm higher. Further reducing EUVL mask blank surface roughness will increase the blank cost with limited benefit in improving the pattern LWR, provided that the intrinsic resist LWR is in the order of 1nm and above.

  20. EUVL mask patterning with blanks from commercial suppliers

    NASA Astrophysics Data System (ADS)

    Yan, Pei-Yang; Zhang, Guojing; Nagpal, Rajesh; Shu, Emily Y.; Li, Chaoyang; Qu, Ping; Chen, Frederick T.

    2004-12-01

    Extreme Ultraviolet Lithography (EUVL) reflective mask blank development includes low thermal expansion material fabrication, mask substrate finishing, reflective multi-layer (ML) and capping layer deposition, buffer (optional)/absorber stack deposition, EUV specific metrology, and ML defect inspection. In the past, we have obtained blanks deposited with various layer stacks from several vendors. Some of them are not commercial suppliers. As a result, the blank and patterned mask qualities are difficult to maintain and improve. In this paper we will present the evaluation results of the EUVL mask pattering processes with the complete EUVL mask blanks supplied by the commercial blank supplier. The EUVL mask blanks used in this study consist of either quartz or ULE substrates which is a type of low thermal expansion material (LTEM), 40 pairs of molybdenum/silicon (Mo/Si) ML layer, thin ruthenium (Ru) capping layer, tantalum boron nitride (TaBN) absorber, and chrome (Cr) backside coating. No buffer layer is used. Our study includes the EUVL mask blank characterization, patterned EUVL mask characterization, and the final patterned EUVL mask flatness evaluation.

  1. MUTAGENICITY OF TEFLON-COATED GLASS FIBER FILTERS: A POTENTIAL PROBLEM AND SOLUTIONS

    EPA Science Inventory

    Teflon-coated glass fiber filters, used in studies of airborne particulate matter, were tested for mutagenic activity using the Salmonella/mammalian-microsome (Ames) assay. For each sample, eight blank filters were simultaneously extracted with dichloromethane (DCM), and the extr...

  2. Trueness, Precision, and Detectability for Sampling and Analysis of Organic Species in Airborne Particulate Matter

    EPA Science Inventory

    Recovery. precision, limits of detection and quantitation, blank levels, calibration linearity, and agreement with certified reference materials were determined for two classes of organic components of airborne particulate matter, polycyclic aromatic hydrocarbons and hopanes usin...

  3. Hydroforming Of Patchwork Blanks — Numerical Modeling And Experimental Validation

    NASA Astrophysics Data System (ADS)

    Lamprecht, Klaus; Merklein, Marion; Geiger, Manfred

    2005-08-01

    In comparison to the commonly applied technology of tailored blanks the concept of patchwork blanks offers a number of additional advantages. Potential application areas for patchwork blanks in automotive industry are e.g. local reinforcements of automotive closures, structural reinforcements of rails and pillars as well as shock towers. But even if there is a significant application potential for patchwork blanks in automobile production, industrial realization of this innovative technique is decelerated due to a lack of knowledge regarding the forming behavior and the numerical modeling of patchwork blanks. Especially for the numerical simulation of hydroforming processes, where one part of the forming tool is replaced by a fluid under pressure, advanced modeling techniques are required to ensure an accurate prediction of the blanks' forming behavior. The objective of this contribution is to provide an appropriate model for the numerical simulation of patchwork blanks' forming processes. Therefore, different finite element modeling techniques for patchwork blanks are presented. In addition to basic shell element models a combined finite element model consisting of shell and solid elements is defined. Special emphasis is placed on the modeling of the weld seam. For this purpose the local mechanical properties of the weld metal, which have been determined by means of Martens-hardness measurements and uniaxial tensile tests, are integrated in the finite element models. The results obtained from the numerical simulations are compared to experimental data from a hydraulic bulge test. In this context the focus is laid on laser- and spot-welded patchwork blanks.

  4. Ecological landscape elements: long-term monitoring in Great Britain, the Countryside Survey 1978-2007 and beyond

    NASA Astrophysics Data System (ADS)

    Wood, Claire M.; Bunce, Robert G. H.; Norton, Lisa R.; Maskell, Lindsay C.; Smart, Simon M.; Scott, W. Andrew; Henrys, Peter A.; Howard, David C.; Wright, Simon M.; Brown, Michael J.; Scott, Rod J.; Stuart, Rick C.; Watkins, John W.

    2018-04-01

    The Countryside Survey (CS) of Great Britain (GB) provides a unique and statistically robust series of datasets, consisting of an extensive set of repeated ecological measurements at a national scale, covering a time span of 29 years. CS was first undertaken in 1978 to provide a baseline for ecological and land use change monitoring in the rural environment of GB, following a stratified random design, based on 1 km squares. Originally, eight random 1 km squares were drawn from each of 32 environmental classes, thus comprising 256 sample squares in the 1978 survey. The number of these sites increased to 382 in 1984, 506 in 1990, 569 in 1998 and 591 in 2007. Detailed information regarding vegetation types and land use was mapped in all five surveys, allowing reporting by defined standard habitat classifications. Additionally, point and linear landscape features (such as trees and hedgerows) are available from all surveys after 1978. From these stratified, randomly located sample squares, information can be converted into national estimates, with associated error terms. Other data, relating to soils, freshwater and vegetation, were also sampled on analogous dates. However, the present paper describes only the surveys of landscape features and habitats. The resulting datasets provide a unique, comprehensive, quantitative ecological coverage of extent and change in these features in GB. Basic results are presented and their implications discussed. However, much opportunity for further analyses remains. Data from each of the survey years are available via the following DOIs: Landscape area data 1978: https://doi.org/10.5285/86c017ba-dc62-46f0-ad13-c862bf31740e, 1984: https://doi.org/10.5285/b656bb43-448d-4b2c-aade-7993aa243ea3, 1990: https://doi.org/10.5285/94f664e5-10f2-4655-bfe6-44d745f5dca7, 1998: https://doi.org/10.5285/1e050028-5c55-42f4-a0ea-c895d827b824, and 2007: https://doi.org/10.5285/bf189c57-61eb-4339-a7b3-d2e81fdde28d; Landscape linear feature data 1984: https://doi.org/10.5285/a3f5665c-94b2-4c46-909e-a98be97857e5, 1990: https://doi.org/10.5285/311daad4-bc8c-485a-bc8a-e0d054889219, 1998: https://doi.org/10.5285/8aaf6f8c-c245-46bb-8a2a-f0db012b2643 and 2007: https://doi.org/10.5285/e1d31245-4c0a-4dee-b36c-b23f1a697f88, Landscape point feature data 1984: https://doi.org/10.5285/124b872e-036e-4dd3-8316-476b5f42c16e, 1990: https://doi.org/10.5285/1481bc63-80d7-4d18-bcba-8804aa0a9e1b, 1998: https://doi.org/10.5285/ed10944f-40c8-4913-b3f5-13c8e844e153 and 2007: https://doi.org/10.5285/55dc5fd7-d3f7-4440-b8a7-7187f8b0550b.

  5. Simultaneous detection of residues of 25 β₂-agonists and 23 β-blockers in animal foods by high-performance liquid chromatography coupled with linear ion trap mass spectrometry.

    PubMed

    Sai, Fan; Hong, Miao; Yunfeng, Zhao; Huijing, Chen; Yongning, Wu

    2012-02-29

    A sensitive method has been developed for the simultaneous determination of residues of 25 β₂-agonists and 23 β-blockers in animal foods by high-performance liquid chromatography coupled with linear ion trap mass spectrometry (HPLC-LIT-MS). This method is based on a new procedure of hydrolysis and extraction by 5% trichloracetic acid, and then cleaned up by mixed strong cation exchange (MCX) cartridges coupled with a novelty cleanup step by methanol. Methanol and 0.1% formic acid were used as mobile phases for gradient elution, while a Supelco Ascentis Express Rp-Amide column was used for LC separation. ESI positive ion scan mode was used with consecutive reaction monitoring (CRM, MS³). Nine β₂-agonists labeled by the deuterium isotope were used as internal standards for quantification. The linear ranges of 48 analytes were from 5 to 200 μg/L; the coefficient of correlation was not less than 0.995. Blank pork muscle, blank liver, and blank kidney were selected as representative matrix for spiked standard recovery test. The recoveries of each compound were in the range of 46.6-118.9%, and the relative standard deviations were in the range of 1.9-28.2%. Decision limits (CCα, α = 0.01) of 48 analytes in muscles, liver, and kidney samples ranged from 0.05 to 0.49 μg/kg, and the detection capability (CCβ, β = 0.05) ranged from 0.13 to 1.64 μg/kg. This method was successfully applied to 110 real animal origin food samples including meat, liver, and kidney of pig and chicken samples.

  6. NHEXAS PHASE I MARYLAND STUDY--QA ANALYTICAL RESULTS FOR PESTICIDES IN REPLICATE SAMPLES

    EPA Science Inventory

    The Pesticides in Replicates data set contains the analytical results of measurements of up to 10 pesticides in 68 replicate (duplicate) samples from 41 households. Measurements were made in samples of indoor air, dust, soil, drinking water, food, and beverages. Duplicate sampl...

  7. High speed reflectometer for EUV mask-blanks

    NASA Astrophysics Data System (ADS)

    Wies, Christian; Lebert, Rainer; Jagle, Bernhard; Juschkin, L.; Sobel, F.; Seitz, H.; Walter, Ronny; Laubis, C.; Scholze, F.; Biel, W.; Steffens, O.

    2005-06-01

    AIXUV GmbH and partners have developed a high speed Reflectometer for EUV mask-blanks which is fully compliant with the SEMI-standard P38 for EUV-mask-blank metrology. The system has been installed in June 2004 at SCHOTT Lithotec AG. It features high throughput, high lateral and spectral resolution, high reproducibility and low absolute uncertainty. Using AIXUV's EUV-LAMP and debris mitigation, low cost-of-ownership and high availability is expected. The spectral reflectance of up to 3 mask-blanks per hour can be measured with at least 20 spots each. The system is push button-controlled. Results are stored in CSV file format. For a spot size of 0.1x1 mm2, 2000 spectral channels of 1.6 pm bandwidth are recorded from 11.6 nm to 14.8 nm. The reflectance measurement is based on the comparison of the sample under test to two reference mirrors calibrated at the PTB radiometry laboratory at BESSY II. The three reflection spectra are recorded simultaneously. For each spot more than 107 photons are accumulated in about 20 s, providing statistical reproducibility below 0.2% RMS. The total uncertainty is below 0.5% absolute. Wavelength calibration better than 1 pm RMS over the whole spectral range is achieved by reference to NIST published wavelengths of about 100 xenon emission lines. It is consistent with the wavelength of the krypton 3d-5p absorption resonance at 13.5947 nm to better than 2 pm.

  8. High speed reflectometer for EUV mask-blanks

    NASA Astrophysics Data System (ADS)

    Wies, C.; Lebert, R.; Jaegle, B.; Juschkin, L.; Sobel, F.; Seitz, H.; Walter, R.; Laubis, C.; Scholze, F.; Biel, W.; Steffens, O.

    2005-05-01

    AIXUV GmbH and partners have developed a high speed Reflectometer for EUV mask-blanks which is fully compliant with the SEMI-standard P38 for EUV-mask-blank metrology. The system has been installed in June 2004 at SCHOTT Lithotec AG. It features high throughput, high lateral and spectral resolution, high reproduci-bility and low absolute uncertainty. Using AIXUV's EUV-LAMP and debris mitigation, low cost-of-ownership and high availability is expected. The spectral reflectance of up to 3 mask-blanks per hour can be measured with at least 20 spots each. The system is push button-controlled. Results are stored in CSV file format. For a spot size of 0.1×1 mm2, 2000 spectral chan-nels of 1.6 pm bandwidth are recorded from 11.6 nm to 14.8 nm. The reflectance measurement is based on the comparison of the sample under test to two reference mirrors calibrated at the PTB radiometry laboratory at BESSY II. The three reflection spectra are recorded simultaneously. For each spot more than 107 photons are ac-cumulated in about 20 s, providing statistical reproducibility below 0.2 % RMS. The total uncertainty is below 0.5 % absolute. Wavelength calibration better than 1 pm RMS over the whole spectral range is achieved by refe-rence to NIST published wavelengths of about 100 xenon emission lines. It is consistent with the wavelength of the krypton 3d-5p absorption resonance at 13.5947 nm to better than 2 pm.

  9. Tank 40 Final SB7b Chemical Characterization Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bannochie, C. J.

    2012-11-06

    A sample of Sludge Batch 7b (SB7b) was taken from Tank 40 in order to obtain radionuclide inventory analyses necessary for compliance with the Waste Acceptance Product Specifications (WAPS). The SB7b WAPS sample was also analyzed for chemical composition including noble metals and fissile constituents. At the Savannah River National Laboratory (SRNL) the 3-L Tank 40 SB7b sample was transferred from the shipping container into a 4-L high density polyethylene bottle and solids were allowed to settle over the weekend. Supernate was then siphoned off and circulated through the shipping container to complete the transfer of the sample. Following thoroughmore » mixing of the 3-L sample, a 558 g sub-sample was removed. This sub-sample was then utilized for all subsequent analytical samples. Eight separate aliquots of the slurry were digested, four with HNO{sub 3}/HCl (aqua regia) in sealed Teflon vessels and four with NaOH/Na{sub 2}O{sub 2} (alkali or peroxide fusion) using Zr crucibles. Two Analytical Reference Glass ? 1 (ARG-1) standards were digested along with a blank for each preparation. Each aqua regia digestion and blank was diluted to 1:100 mL with deionized water and submitted to Analytical Development (AD) for inductively coupled plasma ? atomic emission spectroscopy (ICP-AES) analysis, inductively coupled plasma ? mass spectrometry (ICP-MS) analysis, atomic absorption spectroscopy (AA) for As and Se, and cold vapor atomic absorption spectroscopy (CV-AA) for Hg. Equivalent dilutions of the alkali fusion digestions and blank were submitted to AD for ICP-AES analysis. Tank 40 SB7b supernate was collected from a mixed slurry sample in the SRNL Shielded Cells and submitted to AD for ICP-AES, ion chromatography (IC), total base/free OH{sup -}/other base, total inorganic carbon/total organic carbon (TIC/TOC) analyses, and Cs-137 gamma scan. Weighted dilutions of slurry were submitted for IC, TIC/TOC, and total base/free OH-/other base analyses. Activities for U-233, U-235, and Pu-239 were determined from the ICP-MS data for the aqua regia digestions of the Tank 40 WAPS slurry using the specific activity of each isotope. The Pu-241 value was determined from a Pu-238/-241 method.« less

  10. Extracting metalworking fluid aerosol samples in cassettes by provisional ASTM and NIOSH methods.

    PubMed

    Harper, Martin

    2002-01-01

    Recent provisional methods for the determination of metalworking fluid aerosol in workplace air involve a solvent extraction procedure to separate the nonvolatile fraction of the fluid from insoluble material such as metal turnings and dirt. The procedure calls for preweighing a filter (W1) and assembling it into a cassette and taking a sample. In the laboratory the filter is removed from the cassette, desiccated to remove any collected water or other volatile substances, and weighed again (W2). The filter is then extracted in an organic solvent blend, allowed to dry, and weighed a final time (W3). The total weight collected by the filter is given by (W2-W1), and the weight of (nonvolatile) metalworking fluid collected is given by (W2-W3). The extraction step can take place within a cassette housing if it is relatively inert to the solvent blend used. The extraction of four metalworking fluids (straight oil, soluble oil, synthetic and semisynthetic) within disposable polypropylene cassettes was investigated using the same protocol used to evaluate the original method. For all fluids the extraction efficiency was greater than 95% with a precision better than 5%. The mean blank contribution to the extraction step was 16 micrograms. Blanks were also evaluated after storage, and after transport and storage. A small additional blank contribution could be removed by desiccation. The limits of detection and quantitation of the extraction step were calculated to be 28 and 94 micrograms, respectively.

  11. NHEXAS PHASE I MARYLAND STUDY--QA ANALYTICAL RESULTS FOR METALS IN REPLICATE SAMPLES

    EPA Science Inventory

    The Metals in Replicates data set contains the analytical results of measurements of up to 11 metals in 88 replicate (duplicate) samples from 52 households. Measurements were made in samples of indoor and outdoor air, drinking water, food, and beverages. Duplicate samples for a...

  12. Metal flow of a tailor-welded blank in deep drawing process

    NASA Astrophysics Data System (ADS)

    Yan, Qi; Guo, Ruiquan

    2005-01-01

    Tailor welded blanks were used in the automotive industry to consolidate parts, reduce weight, and increase safety. In recent years, this technology was developing rapidly in China. In Chinese car models, tailor welded blanks had been applied in a lot of automobile parts such as rail, door inner, bumper, floor panel, etc. Concerns on the properties of tailor welded blanks had become more and more important for automobile industry. A lot of research had shown that the strength of the welded seam was higher than that of the base metal, such that the weld failure in the aspect of strength was not a critical issue. However, formability of tailor welded blanks in the stamping process was complex. Among them, the metal flow of tailor welded blanks in the stamping process must be investigated thoroughly in order to reduce the scrap rate during the stamping process in automobile factories. In this paper, the behavior of metal flow for tailor welded blanks made by the laser welding process with two types of different thickness combinations were studied in the deep drawing process. Simulations and experiment verification of the movement of weld line for tailor welded blanks were discussed in detail. Results showed that the control on the movement of welded seam during stamping process by taking some measures in the aspect of blank holder was effective.

  13. System 6: A pricing strategy for long blanks

    Treesearch

    Hugh W. Reynolds; Bruce G. Hansen; Bruce G. Hansen

    1986-01-01

    In System 6, small-diameter, low-grade hardwood timber is used to make blanks in standard sizes. Blanks are made in one thickness and one quality class but in all the standard lengths during each production run. The quantity of blanks per length can be varied, while keeping total yield high, by using proper production control techniques. However, when the percentage of...

  14. Surface modifications of AISI 420 stainless steel by low energy Yttrium ions

    NASA Astrophysics Data System (ADS)

    Nassisi, Vincenzo; Delle Side, Domenico; Turco, Vito; Martina, Luigi

    2018-01-01

    In this work, we study surface modifications of AISI 420 stainless steel specimens in order to improve their surface properties. Oxidation resistance and surface micro-hardness were analyzed. Using an ion beam delivered by a Laser Ion Source (LIS) coupled to an electrostatic accelerator, we performed implantation of low energy yttrium ions on the samples. The ions experienced an acceleration passing through a gap whose ends had a potential difference of 60 kV. The gap was placed immediately before the samples surface. The LIS produced high ions fluxes per laser pulse, up to 3x1011 ions/cm2, resulting in a total implanted flux of 7x1015 ions/cm2. The samples were characterized before and after ion implantation using two analytical techniques. They were also thermally treated to investigate the oxide scale. The crystal phases were identified by an X-ray diffractometer, while the micro-hardness was assayed using the scratch test and a profilometer. The first analysis was applied to blank, implanted and thermally treated sample surface, while the latter was applied only to blank and implanted sample surfaces. We found a slight increase in the hardness values and an increase to oxygen resistance. The implantation technique we used has the advantages, with respect to conventional methods, to modify the samples at low temperature avoiding stray diffusion of ions inside the substrate bulk.

  15. 10 CFR 74.45 - Measurements and measurement control.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... measurements, obtaining samples, and performing laboratory analyses for element concentration and isotope... of random error behavior. On a predetermined schedule, the program shall include, as appropriate: (i) Replicate analyses of individual samples; (ii) Analysis of replicate process samples; (iii) Replicate volume...

  16. 10 CFR 74.45 - Measurements and measurement control.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... measurements, obtaining samples, and performing laboratory analyses for element concentration and isotope... of random error behavior. On a predetermined schedule, the program shall include, as appropriate: (i) Replicate analyses of individual samples; (ii) Analysis of replicate process samples; (iii) Replicate volume...

  17. 10 CFR 74.45 - Measurements and measurement control.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... measurements, obtaining samples, and performing laboratory analyses for element concentration and isotope... of random error behavior. On a predetermined schedule, the program shall include, as appropriate: (i) Replicate analyses of individual samples; (ii) Analysis of replicate process samples; (iii) Replicate volume...

  18. A new compilation of stomach content data for commercially-important pelagic fish species in the Northeast Atlantic

    NASA Astrophysics Data System (ADS)

    Pinnegar, J. K.; Goñi, N.; Trenkel, V. M.; Arrizabalaga, H.; Melle, W.; Keating, J.; Óskarsson, G.

    2014-04-01

    There is increasing demand for information on predator-prey interactions in the ocean as a result of legislative commitments aimed at achieving sustainable exploitation. However, comprehensive datasets are lacking for many fish species and this has hampered development of multispecies fisheries models and the formulation of effective food-web indicators. This work describes a new compilation of stomach content data for five pelagic fish species (herring, blue whiting, mackerel, albacore and bluefin tuna) sampled across the northeast Atlantic and submitted to the PANGAEA open-access data portal (www.pangaea.de). We provide detailed descriptions of sample origin and of the corresponding database structures. We describe the main results in terms of diet composition and predator-prey relationships. The feeding preferences of small pelagic fish (herring, blue whiting, mackerel) were sampled over a very broad geographic area within the North Atlantic basin, from Greenland in the west, to the Lofoten Islands in the east and from the Bay of Biscay northwards to the Arctic. This analysis revealed significant differences in the prey items selected in different parts of the region at different times of year. Tunas (albacore and bluefin) were sampled in the Bay of Biscay and Celtic Sea. Dominant prey items for these species varied by location, year and season. This data compilation exercise represents one of the largest and most wide-ranging ever attempted for pelagic fish in the north Atlantic. The earliest data included in the database were collected in 1864, whereas the most recent were collected in 2012.Datasets are available at doi:10.1594/PANGAEA.820041 and doi:10.1594/PANGAEA.826992.

  19. Modified blank ammunition injuries.

    PubMed

    Ogunc, Gokhan I; Ozer, M Tahir; Coskun, Kagan; Uzar, Ali Ihsan

    2009-12-15

    Blank firing weapons are designed only for discharging blank ammunition cartridges. Because they are cost-effective, are easily accessible and can be modified to live firearms plus their unclear legal situation in Turkish Law makes them very popular in Turkey. 2004 through 2008, a total of 1115 modified blank weapons were seized in Turkey. Blank firing weapons are easily modified by owners, making them suitable for discharging live firearm ammunition or modified blank ammunitions. Two common methods are used for modification of blank weapons. After the modification, these weapons can discharge the live ammunition. However, due to compositional durability problems with these types of weapons; the main trend is to use the modified blank ammunitions rather than live firearm ammunition fired from modified blank firing weapons. In this study, two types of modified blank weapons and two types of modified blank cartridges were tested on three different target models. Each of the models' shooting side was coated with 1.3+/-2 mm thickness chrome tanned cowhide as a skin simulant. The first model was only coated with skin simulant. The second model was coated with skin simulant and 100% cotton police shirt. The third model was coated with skin simulant and jean denim. After the literature evaluation four high risky anatomic locations (the neck area; the eyes; the thorax area and inguinal area) were pointed out for the steel and lead projectiles are discharged from the modified blank weapons especially in close range (0-50 cm). The target models were designed for these anatomic locations. For the target models six Transparent Ballistic Candle blocks (TCB) were prepared and divided into two test groups. The first group tests were performed with lead projectiles and second group with steel projectile. The shortest penetration depth (lead projectile: 4.358 cm; steel projectile 8.032 cm) was recorded in the skin simulant and jean denim coated block for both groups. In both groups, the longest penetration depth (lead projectile: 6.434 cm; steel projectile 8.608 cm) was recorded in the only skin simulant coated block. And the penetration depth of skin simulant and 100% cotton police shirt coated model was 5.870 cm for lead projectile; 8.440 cm for steel projectile. According to penetration results, national and international legislations and production standards should be re-evaluated in order to prevent the modification of blank weapons and ammunitions. There are three methods for preventing modification of blank weapons: completely closed barrel structure; intersected restrain pieces application; eccentric barrel structure.

  20. Determination of Aflatoxins and Ochratoxin A in Traditional Turkish Concentrated Fruit Juice Products by Multi-Immunoaffinity Column Cleanup and LC Fluorescence Detection: Single-Laboratory Validation.

    PubMed

    Kaymak, Tugrul; Türker, Levent; Tulay, Hüseyin; Stroka, Joerg

    2018-04-27

    Background : Pekmez and pestil are traditional Turkish foods made from concentrated grapejuice, which can be contaminated with mycotoxins such as aflatoxins and ochratoxin A (OTA). Objective : To carry out a single-laboratory validation of a method to simultaneously determine aflatoxins B 1 , B₂, G 1 , and G₂ and ochratoxin A in pekmez and pestil. Methods : The homogenized sample is extracted with methanol-water (80 + 20) using a high-speed blender. The (sample) extract is filtered, diluted with phosphate-buffered saline solution, and applied to a multi-immunoaffinity column (AFLAOCHRA PREP®). Aflatoxins and ochratoxin A are removed with (neat) methanol and then directly analyzed by reversed-phase LC with fluorescence detection using post-column bromination (Kobra cell®). Results : Test portions of blank pekmez and pestil were spiked with a mixture of aflatoxins and ochratoxin A to give levels ranging from 2.6 to 10.4 μg/kg and 1.0-4.0 μg/kg, respectively. Recoveries for total aflatoxins and ochratoxin A ranged from 84 to 106% and 80-97%, respectively, for spiked samples. Based on results for spiked pekmez and pestil (30 replicates each at three levels), the repeatability RSD ranged from 1.6 to 12% and 2.7-11% for total aflatoxins and ochratoxin A, respectively. Conclusions : The method performance in terms of recovery, repeatability, and detection limits has been demonstrated to be suitable for use as an Official Method. Highlights : First immunoaffinity column method validated for simultaneous analysis of aflatoxins and ochratoxin A in pekmez and pestil. Suitability for use for official purposes in Turkey, demonstrated by single-laboratory validation. Co-occurrence of aflatoxins and OTA in mulberry and carob pekmez reported for the first time.

  1. Alternating phase-shift mask and binary mask for 45-nm node and beyond: the impact on the mask error control

    NASA Astrophysics Data System (ADS)

    Kojima, Yosuke; Shirasaki, Masanori; Chiba, Kazuaki; Tanaka, Tsuyoshi; Inazuki, Yukio; Yoshikawa, Hiroki; Okazaki, Satoshi; Iwase, Kazuya; Ishikawa, Kiichi; Ozawa, Ken

    2007-05-01

    For 45 nm node and beyond, the alternating phase-shift mask (alt. PSM), one of the most expected resolution enhancement technologies (RET) because of its high image contrast and small mask error enhancement factor (MEEF), and the binary mask (BIM) attract attention. Reducing CD and registration errors and defect are their critical issues. As the solution, the new blank for alt. PSM and BIM is developed. The top film of new blank is thin Cr, and the antireflection film and shielding film composed of MoSi are deposited under the Cr film. The mask CD performance is evaluated for through pitch, CD linearity, CD uniformity, global loading, resolution and pattern fidelity, and the blank performance is evaluated for optical density, reflectivity, sheet resistance, flatness and defect level. It is found that the performance of new blank is equal to or better than that of conventional blank in all items. The mask CD performance shows significant improvement. The lithography performance of new blank is confirmed by wafer printing and AIMS measurement. The full dry type alt. PSM has been used as test plate, and the test results show that new blank can almost meet the specifications of pi-0 CD difference, CD uniformity and process margin for 45 nm node. Additionally, the new blank shows the better pattern fidelity than that of conventional blank on wafer. AIMS results are almost same as wafer results except for the narrowest pattern. Considering the result above, this new blank can reduce the mask error factors of alt. PSM and BIM for 45 nm node and beyond.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yan, Pei-Yang; Zhang, Guojing; Gullickson, Eric M.

    Extreme ultraviolet lithography (EUVL) mask multi-layer (ML) blank surface roughness specification historically comes from blank defect inspection tool requirement. Later, new concerns on ML surface roughness induced wafer pattern line width roughness (LWR) arise. In this paper, we have studied wafer level pattern LWR as a function of EUVL mask surface roughness via High-NA Actinic Reticle Review Tool. We found that the blank surface roughness induced LWR at current blank roughness level is in the order of 0.5nm 3σ for NA=0.42 at the best focus. At defocus of ±40nm, the corresponding LWR will be 0.2nm higher. Further reducing EUVL maskmore » blank surface roughness will increase the blank cost with limited benefit in improving the pattern LWR, provided that the intrinsic resist LWR is in the order of 1nm and above.« less

  3. Ion beam deposition system for depositing low defect density extreme ultraviolet mask blanks

    NASA Astrophysics Data System (ADS)

    Jindal, V.; Kearney, P.; Sohn, J.; Harris-Jones, J.; John, A.; Godwin, M.; Antohe, A.; Teki, R.; Ma, A.; Goodwin, F.; Weaver, A.; Teora, P.

    2012-03-01

    Extreme ultraviolet lithography (EUVL) is the leading next-generation lithography (NGL) technology to succeed optical lithography at the 22 nm node and beyond. EUVL requires a low defect density reflective mask blank, which is considered to be one of the top two critical technology gaps for commercialization of the technology. At the SEMATECH Mask Blank Development Center (MBDC), research on defect reduction in EUV mask blanks is being pursued using the Veeco Nexus deposition tool. The defect performance of this tool is one of the factors limiting the availability of defect-free EUVL mask blanks. SEMATECH identified the key components in the ion beam deposition system that is currently impeding the reduction of defect density and the yield of EUV mask blanks. SEMATECH's current research is focused on in-house tool components to reduce their contributions to mask blank defects. SEMATECH is also working closely with the supplier to incorporate this learning into a next-generation deposition tool. This paper will describe requirements for the next-generation tool that are essential to realize low defect density EUV mask blanks. The goal of our work is to enable model-based predictions of defect performance and defect improvement for targeted process improvement and component learning to feed into the new deposition tool design. This paper will also highlight the defect reduction resulting from process improvements and the restrictions inherent in the current tool geometry and components that are an impediment to meeting HVM quality EUV mask blanks will be outlined.

  4. Differential release of cell-signaling metabolites by male and female bovine embryos cultured in vitro.

    PubMed

    Gómez, E; Carrocera, S; Martin, D; Herrero, P; Canela, N; Muñoz, M

    2018-07-01

    Male and female early bovine embryos show dimorphic transcription that impacts metabolism. Individual release of metabolites was examined in a 24h single culture medium from Day-6 male and female morulae that developed to Day-7 expanded blastocysts. Embryos were produced in vitro, fertilized with a single bull and cultured in SOFaaci+6  g/L BSA. The embryonic sex was identified (amelogenin gene amplification). Embryos (N = 10 males and N = 10 females) and N = 6 blank samples (i.e. SOFaaci+6  g/L BSA incubated with no embryos) were collected from 3 replicates. Metabolome was analyzed by UHPLC-TOF-MS in spent culture medium. After tentative identification, N = 13 metabolites significantly (P < 0.05; ANOVA) differed in their concentrations between male and female embryos, although N = 10 of these metabolites showed heterogeneity (Levene's test; P > 0.05). LysoPC(15:0) was the only metabolite found at higher concentration in females (fold change [FC] male to female = 0.766). FC of metabolites more abundant in male culture medium (N = 12) varied from 1.069 to 1.604. Chemical taxonomy grouped metabolites as amino-acids and related compounds (DL-2 aminooctanoic acid, arginine, 5-hydroxy-l-tryptophan, and palmitoylglycine); lipids (2-hexenoylcarnitine; Lauroyl diethanolamide; 5,6 dihydroxyprostaglandin F1a; LysoPC(15:0); DG(14:0/14:1(9Z)/0:0) and triterpenoid); endogenous amine ((S)-N-Methylsalsolinol/(R)-N-Methylsalsolinol); n-acyl-alpha-hexosamine (N-acetyl-alpha-d-galactosamine 1-phosphate); and dUMP, a product of pyrimidine metabolism. Among the compounds originally contained in CM, female embryos significantly depleted more arginine than males and blank controls (P < 0.001). Male and female embryos induce different concentrations of metabolites with potential signaling effects. The increased abundance of metabolites released from males is consistent with the higher metabolic activity attributed to such blastocysts. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. 40 CFR Appendix A to Subpart E of... - Interim Transmission Electron Microscopy Analytical Methods-Mandatory and Nonmandatory-and...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... representative of the air entering the abatement site. c. Two field blanks are to be taken by removing the cap... of Sample Data Quality Objectives is shown in the following Table II: EC01AP92.003 C. Sample Shipment... or the Burdette procedure (Ref. 7 of Unit II.J.) ii. Plasma etching of the collapsed filter is...

  6. 40 CFR Appendix A to Subpart E of... - Interim Transmission Electron Microscopy Analytical Methods-Mandatory and Nonmandatory-and...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... representative of the air entering the abatement site. c. Two field blanks are to be taken by removing the cap... of Sample Data Quality Objectives is shown in the following Table II: EC01AP92.003 C. Sample Shipment... or the Burdette procedure (Ref. 7 of Unit II.J.) ii. Plasma etching of the collapsed filter is...

  7. Method of making dished ion thruster grids

    NASA Technical Reports Server (NTRS)

    Banks, B. A. (Inventor)

    1975-01-01

    A pair of flat grid blanks are clamped together at their edges with an impervious metal sheet on top. All of the blanks and sheets are dished simultaneously by forcing fluid to inflate an elastic sheet which contacts the bottom grid blank. A second impervious metal sheet is inserted between the two grid blanks if the grids have high percentage open areas. The dished grids are stress relieved simultaneously.

  8. Effects of Blank Curvature and Tool Conditions on the Spring Back of Thin Sheet Panel Formed through Local Embossing and Edge L-Bending

    NASA Astrophysics Data System (ADS)

    Park, Keecheol; Park, Jongyoun; Nam, Jaebok

    2011-08-01

    Due to the application of thinner sheet steels, the stamped panels in the forming process, generally, are severely distorted. The wavy shape of embossed panel finally converted to residual stress embedded in the panel at final forming (edge L-bending) and it is known as the cause of twisting and oil canning of spring backed panel. Another important source of stamped shape deviation is the curvature of blank. The effects of blank curvature on the shape defects (panel curvature and twisting) after stamping were investigated from defective panel analysis, model experiment and stamping simulation. And the effect of tool conditions (BHF and bead height change) on spring backed shape of real TV bottom chassis were studied. The initial curvature of blank was remained in the flat area of stamped panels as width directional curvature. It converted from length direction curvature of blank. The curvature of initial blank reduced the wavy shape after local emboss forming, but twisting after edge L-bending was increased at large blank curvature cases. The effects of emboss forming conditions, the forming heights and blank holding force were studied and it was found that the wavy shape of stamped sheet was rapidly changed although the forming conditions altered very small amount.

  9. An update of hydrologic conditions and distribution of selected constituents in water, eastern Snake River Plain aquifer and perched groundwater zones, Idaho National Laboratory, Idaho, emphasis 2009–11

    USGS Publications Warehouse

    Davis, Linda C.; Bartholomay, Roy C.; Rattray, Gordon W.

    2013-01-01

    Since 1952, wastewater discharged to infiltration ponds (also called percolation ponds) and disposal wells at the Idaho National Laboratory (INL) has affected water quality in the eastern Snake River Plain (ESRP) aquifer and perched groundwater zones underlying the INL. The U.S. Geological Survey (USGS), in cooperation with the U.S. Department of Energy, maintains groundwater monitoring networks at the INL to determine hydrologic trends, and to delineate the movement of radiochemical and chemical wastes in the aquifer and in perched groundwater zones. This report presents an analysis of water-level and water-quality data collected from aquifer, multilevel monitoring system (MLMS), and perched groundwater wells in the USGS groundwater monitoring networks during 2009–11. Water in the ESRP aquifer primarily moves through fractures and interflow zones in basalt, generally flows southwestward, and eventually discharges at springs along the Snake River. The aquifer primarily is recharged from infiltration of irrigation water, infiltration of streamflow, groundwater inflow from adjoining mountain drainage basins, and infiltration of precipitation. From March–May 2009 to March–May 2011, water levels in wells generally declined in the northern part of the INL. Water levels generally rose in the central and eastern parts of the INL. Detectable concentrations of radiochemical constituents in water samples from aquifer wells or MLMS equipped wells in the ESRP aquifer at the INL generally decreased or remained constant during 2009–11. Decreases in concentrations were attributed to radioactive decay, changes in waste-disposal methods, and dilution from recharge and underflow. In 2011, concentrations of tritium in groundwater from 50 of 127 aquifer wells were greater than or equal to the reporting level and ranged from 200±60 to 7,000±260 picocuries per liter. Tritium concentrations from one or more discrete zones from four wells equipped with MLMS were greater than or equal to reporting levels in water samples collected at various depths. Tritium concentrations in water from wells completed in shallow perched groundwater at the Advanced Test Reactor Complex (ATR Complex) were less than the reporting levels. Tritium concentrations in deep perched groundwater at the ATR Complex equaled or exceeded the reporting level in 12 wells during at least one sampling event during 2009–11 at the ATR Complex. Concentrations of strontium-90 in water from 20 of 76 aquifer wells sampled during April or October 2011 exceeded the reporting level. Strontium-90 was not detected within the ESRP aquifer beneath the ATR Complex. During at least one sampling event during 2009–11, concentrations of strontium-90 in water from 10 wells completed in deep perched groundwater at the ATR Complex equaled or exceeded the reporting levels. During 2009–11, concentrations of plutonium-238, and plutonium-239, -240 (undivided), and americium-241 were less than the reporting level in water samples from all aquifer wells and in all wells equipped with MLMS. Concentrations of cesium-137 were equal to or slightly above the reporting level in 8 aquifer wells and from 2 wells equipped with MLMS. The concentration of chromium in water from one well south of the ATR Complex was 97 micrograms per liter (μg/L) in April 2011, just less than the maximum contaminant level (MCL) of 100 μg/L. Concentrations of chromium in water samples from 69 other wells sampled ranged from 0.8 μg/L to 25 μg/L. During 2009–11, dissolved chromium was detected in water from 15 wells completed in perched groundwater at the ATR Complex. In 2011, concentrations of sodium in water from most wells in the southern part of the INL were greater than the background concentration of 10 milligrams per liter (mg/L); the highest concentrations were at or near the Idaho Nuclear Engineering and Technology Center (INTEC). After the newpercolation ponds were put into service in 2002 southwest of the INTEC, concentrations of sodium in water samples from the Rifle Range well rose steadily until 2008, when the concentrations generally began decreasing. The increases and decreases were attributed to disposal variability in the new percolation ponds. Concentrations of sodium in most wells equipped with MLMS generally were consistent with depth. During 2011, dissolved sodium concentrations in water from 17 wells completed in deep perched groundwater at the ATR Complex ranged from 6 to 146 mg/L. In 2011, concentrations of chloride in most water samples from aquifer wells south of the INTEC and at the Central Facilities Area exceeded the background concentrations of 15 mg/L, but were less than the secondary MCL of 250 mg/L. Chloride concentrations in water from wells south of the INTEC have generally increased because of increased chloride disposal to the old percolation ponds since 1984 when discharge of wastewater to the INTEC disposal well was discontinued. After the new percolation ponds were put into service in 2002 southwest of the INTEC, concentrations of chloride in water samples from one well rose steadily until 2008 then began decreasing. Chloride concentrations in water from all but one well completed in the ESRP aquifer at or near the ATR Complex were less than background and ranged between 10 and 14 mg/L during 2011, similar to concentrations detected during the 2006–08 reporting period. During 2011, chloride concentrations in water from two aquifer wells at the Radioactive Waste Management Complex (RWMC) were slightly greater than concentrations detected during the 2006–08 reporting period. The vertical distribution of chloride concentrations in wells equipped with MLMS were generally consistent within zones during 2009–11 and ranged from about 8 to 20 mg/L. During April 2011, dissolved chloride concentrations in shallow perched groundwater at the ATR Complex ranged from 7 to 13 mg/L in water from three wells. Dissolved chloride concentrations in deep perched groundwater at the ATR Complex during 2011 ranged from 4 to 54 mg/L. In 2011, sulfate concentrations in water samples from 11 aquifer wells in the south-central part of the INL equaled or exceeded the background concentration of sulfate and ranged from 40 to 167 mg/L. The greater-than-background concentrations in water from these wells probably resulted from sulfate disposal at the ATR Complex infiltration ponds or the old INTEC percolation ponds. In 2011, sulfate concentrations in water samples from two wells near the RWMC were greater than background levels and could have resulted from well construction techniques and (or) waste disposal at the RWMC. The vertical distribution of sulfate concentrations in three wells near the southern boundary of the INL was generally consistent with depth, and ranged between 19 and 25 mg/L. The maximum dissolved sulfate concentration in shallow perched groundwater near the ATR Complex was 400 mg/L in well CWP 1 in April 2011. During 2009–11, the maximum concentration of dissolved sulfate in deep perched groundwater at the ATR Complex was 1,550 mg/L in a well located west of the chemical-waste pond. In 2011, concentrations of nitrate in water from most wells at and near the INTEC exceeded the regional background concentrations of 1 mg/L and ranged from 1.6 to 5.95 mg/L. Concentrations of nitrate in wells south of INTEC and farther away from the influence of disposal areas and the Big Lost River show a general decrease in nitrate concentrations through time. During 2009–11, water samples from 30 wells were collected and analyzed for volatile organic compounds (VOCs). Six VOCs were detected. At least one and up to five VOCs were detected in water samples from 10 wells. The primary VOCs detected include carbon tetrachloride, chloroform, tetrachloroethylene, 1,1,1-trichloroethane, and trichloroethylene. In 2011, concentrations for all VOCs were less than their respective MCL for drinking water, except carbon tetrachloride in water from two wells. During 2009–11, variability and bias were evaluated from 56 replicate and 16 blank quality-assurance samples. Results from replicate analyses were investigated to evaluate sample variability. Constituents with acceptable reproducibility were stable isotope ratios, major ions, nutrients, and VOCs. All radiochemical constituents and trace metals had acceptable reproducibility except for gross beta-particle radioactivity, aluminum, antimony, and cobalt. Bias from sample contamination was evaluated from equipment, field, container, and source-solution blanks. No detectable constituent concentrations were reported for equipment blanks of the thief samplers and sampling pipes or for the source-solution and field blanks. Equipment blanks of bailers had detectable concentrations of strontium-90, sodium, chloride, and sulfate, and the container blank had a detectable concentration of dichloromethane.

  10. Consolidation quality and mechanical performance of stamp formed tailored blanks produced by rapid AFP

    NASA Astrophysics Data System (ADS)

    Slange, T. K.; Warnet, L. L.; Grouve, W. J. B.; Akkerman, R.

    2018-05-01

    Stamp forming is a rapid manufacturing technology used to shape flat blanks of thermoplastic composite material into three-dimensional components. The combination with rapid AFP as blank manufacturing technology can further extend the applicability of stamp forming by allowing rapid lay-up of tailored blanks and offering partial preconsolidation. In an experimental study it is demonstrated that high quality laminates with good flexural strength can be obtained by following this process route. The consolidation of ply-drop regions is demonstrated by flat laminates with a thickness step. The influence of fiber orientations, blank-tooling misalignments and AFP tolerances is investigated.

  11. DAMe: a toolkit for the initial processing of datasets with PCR replicates of double-tagged amplicons for DNA metabarcoding analyses.

    PubMed

    Zepeda-Mendoza, Marie Lisandra; Bohmann, Kristine; Carmona Baez, Aldo; Gilbert, M Thomas P

    2016-05-03

    DNA metabarcoding is an approach for identifying multiple taxa in an environmental sample using specific genetic loci and taxa-specific primers. When combined with high-throughput sequencing it enables the taxonomic characterization of large numbers of samples in a relatively time- and cost-efficient manner. One recent laboratory development is the addition of 5'-nucleotide tags to both primers producing double-tagged amplicons and the use of multiple PCR replicates to filter erroneous sequences. However, there is currently no available toolkit for the straightforward analysis of datasets produced in this way. We present DAMe, a toolkit for the processing of datasets generated by double-tagged amplicons from multiple PCR replicates derived from an unlimited number of samples. Specifically, DAMe can be used to (i) sort amplicons by tag combination, (ii) evaluate PCR replicates dissimilarity, and (iii) filter sequences derived from sequencing/PCR errors, chimeras, and contamination. This is attained by calculating the following parameters: (i) sequence content similarity between the PCR replicates from each sample, (ii) reproducibility of each unique sequence across the PCR replicates, and (iii) copy number of the unique sequences in each PCR replicate. We showcase the insights that can be obtained using DAMe prior to taxonomic assignment, by applying it to two real datasets that vary in their complexity regarding number of samples, sequencing libraries, PCR replicates, and used tag combinations. Finally, we use a third mock dataset to demonstrate the impact and importance of filtering the sequences with DAMe. DAMe allows the user-friendly manipulation of amplicons derived from multiple samples with PCR replicates built in a single or multiple sequencing libraries. It allows the user to: (i) collapse amplicons into unique sequences and sort them by tag combination while retaining the sample identifier and copy number information, (ii) identify sequences carrying unused tag combinations, (iii) evaluate the comparability of PCR replicates of the same sample, and (iv) filter tagged amplicons from a number of PCR replicates using parameters of minimum length, copy number, and reproducibility across the PCR replicates. This enables an efficient analysis of complex datasets, and ultimately increases the ease of handling datasets from large-scale studies.

  12. Effect of slurry ice on the functional properties of proteins related to quality loss during skipjack tuna (Katsuwonus pelamis) chilled storage.

    PubMed

    Zhang, Bin; Deng, Shang-gui; Gao, Meng; Chen, Jing

    2015-04-01

    The effect of slurry ice on the quality of Skipjack tuna (Katsuwonus pelamis) during chilling storage was investigated and compared to flake ice. Slurry ice-treated samples showed significantly higher springiness and chewiness variables than the blank and flake ice-treated samples (P < 0.05). The growth of microorganisms in tuna muscle treated with slurry ice was also down significantly (P < 0.05), and the total aerobic counts didn't reach higher scores than 5.0 log CFU/g during the whole chilling storage. Additionally, the myofibrillar protein, Ca(2+)-ATPase activity, and total sulfydryl (SH) content in muscle treated with slurry ice were all significantly higher than the blank and flake-iced samples (P < 0.05). This was probably due to the faster cooling, subzero final-temperature, and larger heat exchange derived from slurry ice. Standard error of mean and sodium dodecyl sulfate-polyacrylamide gel electrophoresis results also confirmed that slurry ice treatment could effectively retard the degradation of myofibrillar proteins and showed a positive effect on the stability of tissue structures. © 2015 Institute of Food Technologists®

  13. An effective method of UV-oxidation of dissolved organic carbon in natural waters for radiocarbon analysis by accelerator mass spectrometry

    NASA Astrophysics Data System (ADS)

    Xue, Yuejun; Ge, Tiantian; Wang, Xuchen

    2015-12-01

    Radiocarbon (14C) measurement of dissolved organic carbon (DOC) is a very powerful tool to study the sources, transformation and cycling of carbon in the ocean. The technique, however, remains great challenges for complete and successful oxidation of sufficient DOC with low blanks for high precision carbon isotopic ratio analysis, largely due to the overwhelming proportion of salts and low DOC concentrations in the ocean. In this paper, we report an effective UV-Oxidation method for oxidizing DOC in natural waters for radiocarbon analysis by accelerator mass spectrometry (AMS). The UV-oxidation system and method show 95%±4% oxidation efficiency and high reproducibility for DOC in both river and seawater samples. The blanks associated with the method was also low (about 3 µg C) that is critical for 14C analysis. As a great advantage of the method, multiple water samples can be oxidized at the same time so it reduces the sample processing time substantially compared with other UV-oxidation method currently being used in other laboratories. We have used the system and method for 14C studies of DOC in rivers, estuaries, and oceanic environments and have received promise results.

  14. Cheating the Business Template: Filling in the Blanks

    ERIC Educational Resources Information Center

    Mechenbier, Mahli Xuan

    2011-01-01

    Business professionals often use standard templates when composing documents, and teachers of business writing direct students to textbook examples to use as sample formats. Good instructors do want to provide their students with informative examples of what is expected, especially in an online course environment where students cannot raise their…

  15. 21 CFR 177.1010 - Acrylic and modified acrylic plastics, semirigid and rigid.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 0.3 milligram per square inch of surface tested. (2) Potassium permanganate oxidizable distilled... permanganate test shall be determined by preparing duplicate permanganate test blanks according to paragraph (c... permanganate test determinations shall be run on samples of distilled water and 8 and 50 percent alcohol...

  16. Flight dynamics system software development environment (FDS/SDE) tutorial

    NASA Technical Reports Server (NTRS)

    Buell, John; Myers, Philip

    1986-01-01

    A sample development scenario using the Flight Dynamics System Software Development Environment (FDS/SDE) is presented. The SDE uses a menu-driven, fill-in-the-blanks format that provides online help at all steps, thus eliminating lengthy training and allowing immediate use of this new software development tool.

  17. Hypothesis Sampling Systems among Preoperational and Concrete Operational Kindergarten Children

    ERIC Educational Resources Information Center

    Gholson, Barry; And Others

    1976-01-01

    Preoperational and concrete operational kindergarten children received stimulus differentiation training, either with or without feedback, and then a series of discrimination learning problems in which a blank trial probe was used to detect a child's hypothesis after each feedback trial. Piagetian stage theory requires elaboration to account…

  18. Avoidance of Cigarette Pack Health Warnings among Regular Cigarette Smokers

    PubMed Central

    Maynard, Olivia M.; Attwood, Angela; O’Brien, Laura; Brooks, Sabrina; Hedge, Craig; Leonards, Ute; Munafò, Marcus R.

    2016-01-01

    Background Previous research with adults and adolescents indicates that plain cigarette packs increase visual attention to health warnings among non-smokers and non-regular smokers, but not among regular smokers. This may be because regular smokers: 1) are familiar with the health warnings, 2) preferentially attend to branding, or 3) actively avoid health warnings. We sought to distinguish between these explanations using eye-tracking technology. Method A convenience sample of 30 adult dependant smokers were recruited to participate in an eye-tracking study. Participants viewed branded, plain and blank packs of cigarettes with familiar and unfamiliar health warnings. The number of fixations to health warnings and branding on the different pack types were recorded. Results Analysis of variance indicated that regular smokers were biased towards fixating the branding location rather than the health warning location on all three pack types (p < 0.002). This bias was smaller, but still evident, for blank packs, where smokers preferentially attended the blank region over the health warnings. Time-course analysis showed that for branded and plain packs, attention was preferentially directed to the branding location for the entire 10 seconds of the stimulus presentation, while for blank packs this occurred for the last 8 seconds of the stimulus presentation. Familiarity with health warnings had no effect on eye gaze location. Conclusion Smokers actively avoid cigarette pack health warnings, and this remains the case even in the absence of salient branding information. Smokers may have learned to divert their attention away from cigarette pack health warnings. These findings have policy implications for the design of health warning on cigarette packs. PMID:24485554

  19. Nutrient and pesticide contamination bias estimated from field blanks collected at surface-water sites in U.S. Geological Survey Water-Quality Networks, 2002–12

    USGS Publications Warehouse

    Medalie, Laura; Martin, Jeffrey D.

    2017-08-14

    Potential contamination bias was estimated for 8 nutrient analytes and 40 pesticides in stream water collected by the U.S. Geological Survey at 147 stream sites from across the United States, and representing a variety of hydrologic conditions and site types, for water years 2002–12. This study updates previous U.S. Geological Survey evaluations of potential contamination bias for nutrients and pesticides. Contamination is potentially introduced to water samples by exposure to airborne gases and particulates, from inadequate cleaning of sampling or analytic equipment, and from inadvertent sources during sample collection, field processing, shipment, and laboratory analysis. Potential contamination bias, based on frequency and magnitude of detections in field blanks, is used to determine whether or under what conditions environmental data might need to be qualified for the interpretation of results in the context of comparisons with background levels, drinking-water standards, aquatic-life criteria or benchmarks, or human-health benchmarks. Environmental samples for which contamination bias as determined in this report applies are those from historical U.S. Geological Survey water-quality networks or programs that were collected during the same time frame and according to the same protocols and that were analyzed in the same laboratory as field blanks described in this report.Results from field blanks for ammonia, nitrite, nitrite plus nitrate, orthophosphate, and total phosphorus were partitioned by analytical method; results from the most commonly used analytical method for total phosphorus were further partitioned by date. Depending on the analytical method, 3.8, 9.2, or 26.9 percent of environmental samples, the last of these percentages pertaining to all results from 2007 through 2012, were potentially affected by ammonia contamination. Nitrite contamination potentially affected up to 2.6 percent of environmental samples collected between 2002 and 2006 and affected about 3.3 percent of samples collected between 2007 and 2012. The percentages of environmental samples collected between 2002 and 2011 that were potentially affected by nitrite plus nitrate contamination were 7.3 for samples analyzed with the low-level method and 0.4 for samples analyzed with the standard-level method. These percentages increased to 14.8 and 2.2 for samples collected in 2012 and analyzed using replacement low- and standard-level methods, respectively. The maximum potentially affected concentrations for nitrite and for nitrite plus nitrate were much less than their respective maximum contamination levels for drinking-water standards. Although contamination from particulate nitrogen can potentially affect up to 21.2 percent and that from total Kjeldahl nitrogen can affect up to 16.5 percent of environmental samples, there are no critical or background levels for these substances.For total nitrogen, orthophosphate, and total phosphorus, contamination in a small percentage of environmental samples might be consequential for comparisons relative to impairment risks or background levels. At the low ends of the respective ranges of impairment risk for these nutrients, contamination in up to 5 percent of stream samples could account for at least 23 percent of measured concentrations of total nitrogen, for at least 40 or 90 percent of concentrations of orthophosphate, depending on the analytical method, and for 31 to 76 percent of concentrations of total phosphorus, depending on the time period.Twenty-six pesticides had no detections in field blanks. Atrazine with 12 and metolachlor with 11 had the highest number of detections, mostly occurring in spring or early summer. At a 99-percent level of confidence, contamination was estimated to be no greater than the detection limit in at least 98 percent of all samples for 38 of 40 pesticides. For metolachlor and atrazine, potential contamination was no greater than 0.0053 and 0.0093 micrograms per liter in 98 percent of samples. For 11 of 14 pesticides with at least one detection, the maximum potentially affected concentration of the environmental sample was less than their respective human-health or aquatic-life benchmarks. Small percentages of environmental samples had concentrations high enough that atrazine contamination potentially could account for the entire aquatic-life benchmark for acute effects on nonvascular plants, that dieldrin contamination could account for up to 100 percent of the cancer health-based screening level, or that chlorpyrifos contamination could account for 13 or 12 percent of the concentrations in the aquatic-life benchmarks for chronic effects on invertebrates or the criterion continuous concentration for chronic effects on aquatic life.

  20. MULTIELEMENT SOLID PHASE PRECONCENTRATION USING A CHELATING RESIN OF STYRENE DIVINYLBENZENE COPOLYMER AND APPLICATION TO ANALYSIS OF SEAWATER AND FISH OTOLITHS BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY (ICP�MS)

    PubMed Central

    Zereen, Fahmida; Yilmaz, Vedat; Arslan, Zikri

    2013-01-01

    A new chelating resin has been synthesized by immobilizing 4–(2–thiazolylazo) resorcinol (TAR) onto styrene divinlybenzene copolymer and examined for on-line solid phase extraction/preconcentration of Cd, Co, Cu, Ni, Pb and Zn in seawater and fish otoliths for determination by inductively plasma mass spectrometry (ICP-MS). A volume of 5.0 mL sample solution was loaded onto the mini column of TAR immobilized resin at 2.0 mL min−1 via a sequential injection system. The optimum pH for multielement preconcentration was around pH 5.5. Recoveries were better than 96% in artificial seawater. Elution was achieved with 1.0 mL of 0.75 mol L−1 HNO3. The resin possesses large sorption capacity ranging from 82.0 µmol g−1 for Pb to 319 µmol g−1 for Cu. The detection limits (3s) varied between 0.0016 µg L−1 (Cd) and to 0.015 µg L−1 (Zn) for preconcentration of 5.0 mL blank solutions (pH 5.5). Relative standard deviation (RSD)for three replicate runs was between 0.3% (Cd) and 6% (Zn) at 1.0 µg L−1 level. The procedure was validated by analysis of Nearshore Seawater certified reference material (CASS–4), and then successfully applied to the determination of the trace elements in fish otoliths (CRM 22) and in coastal seawater and estuarine water samples. PMID:24976635

  1. Testing glueline continuity in standard-size hardwood blanks by mechanical methods

    Treesearch

    David W. Patterson; Nathan D. Hesterman; Charles Gatchell

    1991-01-01

    Glueline continuity is very critical in standard-size hardwood blanks because the blanks are cut up into small furniture parts, and a small gap in the glueline of a blank may extend across the whole part—or a gap may appear as a crack in the final product. Strength is not a critical factor. The objective of this study was to determine if a gap in a glueline can be...

  2. Toward Radiocarbon Measurement of Individual Amino Acids in Marine Dissolved Organic Matter (DOM): Δ14C Blank Quantification for an HPLC Purification Method.

    NASA Astrophysics Data System (ADS)

    Bour, A. L.; Broek, T.; Walker, B. D.; Mccarthy, M. D.

    2014-12-01

    The presence of much of the marine dissolved organic nitrogen (DON) pool as uncharacterized, biologically recalcitrant molecules is a central mystery in the marine nitrogen cycle. Radiocarbon (Δ14C) isotopic measurements have been perhaps the most important data constraining the cycling of dissolved organic matter (DOM), but little Δ14C data specific to DON is available. Amino acids (AAs) are the major component of DON that can be isolated on a molecular level. Δ14C measurements for the operational "protein-like" fraction of DOM in the deep ocean indicate that this compound class has radiocarbon ages greater than several ocean mixing cycles, suggesting remarkable preservation of labile AAs exported from the surface. However, it is possible that the previously defined operational "protein-like" fraction may also contain non-AA material. Radiocarbon measurement of purified individual AAs would provide a more direct and reliable proxy for DON Δ14C age and cycling rate. We present here Δ14C blank characterization of an AA purification method based on HPLC, with on-line fraction collection. This method allows the recovery of unmodified AAs, but accurate measurement of small AA samples that can be extracted from DOM requires a system with extremely low Δ 14C blanks. Here we assess the impact of HPLC purification on the Δ14C age of known amino acids standards. Individual AA standards with contrasting (modern vs. dead) and well- characterized Δ14C ages were processed in a range of sample sizes. The eluted peaks were collected and dried, and measurement of their post-chromatography Δ14C content allowed for determination of the Δ14C blank by method of additions. The same protocol was applied to a mixture of six AA standards, to evaluate tailing effects in consecutive AA peaks of contrasting Δ14C age. AA standards were selected to include both Δ14C modern and dead AAs that elute both early and late in the chromatographic solvent program. We discuss implications for future Δ14C analysis of AAs purified from DOM by this method.

  3. Seeing Red and Shooting Blanks: A Study of Red Quasars And Blank Field X-Ray Sources

    NASA Technical Reports Server (NTRS)

    Oliversen, Ronald J. (Technical Monitor); Elvis, Martin

    2003-01-01

    The primary source catalog of 'blanks' (bright ROSAT sources with no optical counterparts) has been published in the Astrophysical Journal. The first follow-up paper has also been published. This paper used a combination of ROSAT, Chandra and ground based data to convincingly identify one of the blanks as a Ultra-luminous X-ray source (ULX) in a spiral galaxy. A paper detailing optical and near-IR imaging observations of the remaining sources is underway.

  4. Experimental Research on the Elastic Deformation Mode of S235JR Rolled Steel Fastened between the Centers of a Universal Lathe

    NASA Astrophysics Data System (ADS)

    Tabacaru, LL; Axinte, E.; Musca, G.

    2016-11-01

    Elastic deformations of the technological system occur during the mechanical treatment of a blank, regardless of the manner in which it is fastened. The elastic deformation of the blank is significant especially when machining shaft-like parts. The purpose of our research is to compare the mathematical model of blank deformation to the experimental model when the blank, which is a part belonging to the shaft class, is fastened between centers.

  5. The information gained from witnesses' responses to an initial "blank" lineup.

    PubMed

    Palmer, Matthew A; Brewer, Neil; Weber, Nathan

    2012-10-01

    Wells ("The psychology of lineup identifications," Journal of Applied Social Psychology, 1984, 14, 89-103) proposed that a blank lineup (an initial lineup of known-to-be-innocent foils) can be used to screen eyewitnesses; witnesses who chose from a blank lineup (initial choosers) were more likely to make an error on a second lineup that contained a suspect than were witnesses who rejected a blank lineup (initial nonchoosers). Recent technological advances (e.g., computer-administered lineups) may overcome many of the practical difficulties cited as a barrier to the use of blank lineups. Our research extended knowledge about the blank lineup procedure by investigating the underlying causes of the difference in identification performance between initial choosers and initial nonchoosers. Studies 1a and 1b (total, N = 303) demonstrated that initial choosers were more likely to reject a second lineup than initial nonchoosers and witnesses who did not view a blank lineup, implying that cognitive biases (e.g., confirmation bias and commitment effects) influenced initial choosers' identification decisions. In Study 2 (N = 200), responses on a forced-choice identification test provided evidence that initial choosers have, on average, poorer memories for the culprit than do initial nonchoosers. We also investigated the usefulness of blank lineups for interpreting identification evidence. Diagnosticity ratios suggested that suspect identifications made by initial nonchoosers (cf. initial choosers) should have a greater impact on estimates of the likely guilt of the suspect. Furthermore, for initial nonchoosers, higher confidence in blank lineup rejections was associated with higher diagnosticity for subsequent suspect identifications. These results have implications for policy to guide the collection and interpretation of identification evidence. PsycINFO Database Record (c) 2012 APA, all rights reserved.

  6. Tank 40 Final Sludge Batch 8 Chemical Characterization Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bannochie, Christopher J.

    2013-09-19

    A sample of Sludge Batch 8 (SB8) was pulled from Tank 40 in order to obtain radionuclide inventory analyses necessary for compliance with the Waste Acceptance Product Specifications (WAPS). The SB8 WAPS sample was also analyzed for chemical composition, including noble metals, and fissile constituents, and these results are reported here. These analyses along with the WAPS radionuclide analyses will help define the composition of the sludge in Tank 40 that is currently being fed to the Defense Waste Processing Facility (DWPF) as SB8. At SRNL, the 3-L Tank 40 SB8 sample was transferred from the shipping container into amore » 4-L high density polyethylene bottle and solids were allowed to settle. Supernate was then siphoned off and circulated through the shipping container to complete the transfer of the sample. Following thorough mixing of the 3-L sample, a 553 g sub-sample was removed. This sub-sample was then utilized for all subsequent slurry sample preparations. Eight separate aliquots of the slurry were digested, four with HNO{sub 3}/HCl (aqua regia) in sealed Teflon(r) vessels and four with NaOH/Na{sub 2}O{sub 2} (alkali or peroxide fusion) using Zr crucibles. Two Analytical Reference Glass - 1 (ARG-1) standards were digested along with a blank for each preparation. Each aqua regia digestion and blank was diluted to 1:100 mL with deionized water and submitted to Analytical Development (AD) for inductively coupled plasma - atomic emission spectroscopy (ICP-AES) analysis, inductively coupled plasma - mass spectrometry (ICP-MS) analysis, atomic absorption spectroscopy (AA) for As and Se, and cold vapor atomic absorption spectroscopy (CV-AA) for Hg. Equivalent dilutions of the alkali fusion digestions and blank were submitted to AD for ICP-AES analysis. Tank 40 SB8 supernate was collected from a mixed slurry sample in the SRNL Shielded Cells and submitted to AD for ICP-AES, ion chromatography (IC), total base/free OH-/other base, total inorganic carbon/total organic carbon (TIC/TOC) analyses. Weighted dilutions of slurry were submitted for IC, TIC/TOC, and total base/free OH-/other base analyses. Activities for U-233, U-235, and Pu-239 were determined from the ICP-MS data for the aqua regia digestions of the Tank 40 WAPS slurry using the specific activity of each isotope. The Pu-241 value was determined from a Pu-238/-241 method developed by SRNL AD and previously described.« less

  7. Tank 40 final sludge batch 9 chemical and fissile radionuclide characterization results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bannochie, C. J.; Kubilius, W. P.; Pareizs, J. M.

    A sample of Sludge Batch (SB) 9 was pulled from Tank 40 in order to obtain radionuclide inventory analyses necessary for compliance with the Waste Acceptance Product Specifications (WAPS)i. The SB9 WAPS sample was also analyzed for chemical composition, including noble metals, and fissile constituents, and these results are reported here. These analyses along with the WAPS radionuclide analyses will help define the composition of the sludge in Tank 40 that is fed to the Defense Waste Processing Facility (DWPF) as SB9. At the Savannah River National Laboratory (SRNL), the 3-L Tank 40 SB9 sample was transferred from the shippingmore » container into a 4-L high density polyethylene bottle and solids were allowed to settle. Supernate was then siphoned off and circulated through the shipping container to complete the transfer of the sample. Following thorough mixing of the 3-L sample, a 547 g sub-sample was removed. This sub-sample was then utilized for all subsequent slurry sample preparations. Eight separate aliquots of the slurry were digested, four with HNO3/HCl (aqua regiaii) in sealed Teflon® vessels and four with NaOH/Na2O2 (alkali or peroxide fusioniii) using Zr crucibles. Three Analytical Reference Glass – 1iv (ARG-1) standards were digested along with a blank for each preparation. Each aqua regia digestion and blank was diluted to 1:100 with deionized water and submitted to Analytical Development (AD) for inductively coupled plasma – atomic emission spectroscopy (ICP-AES) analysis, inductively coupled plasma – mass spectrometry (ICP-MS) analysis, atomic absorption spectroscopy (AA) for As and Se, and cold vapor atomic absorption spectroscopy (CV-AA) for Hg. Equivalent dilutions of the alkali fusion digestions and blank were submitted to AD for ICP-AES analysis. Tank 40 SB9 supernate was collected from a mixed slurry sample in the SRNL Shielded Cells and submitted to AD for ICP-AES, ion chromatography (IC), total base/free OH-/other base, total inorganic carbon/total organic carbon (TIC/TOC) analyses. Weighted dilutions of slurry were submitted for IC, TIC/TOC, and total base/free OH-/other base analyses. Activities for U-233, U-235, and Pu-239 were determined from the ICP-MS data for the aqua regia digestions of the SB9 WAPS slurry using the specific activity of each isotope. The Pu-241 value was determined from a Pu-238/-241 method developed by SRNL AD and previously described.v« less

  8. Piezoelectric resonator assembly with thin molybdenum mounting clips

    DOEpatents

    Peters, R. Donald

    1981-01-01

    A resonator mounting assembly wherein the resonator blank is mounted agai an essentially planar surface presented by a plurality of peripherally disposed mounting clips and bonded to this surface to provide substantially all the mechanical support for the blank in a direction normal to the major faces of the resonator blank, while being flexible in the directions parallel to said major faces so as to minimize radial stresses on the resonator blank, particularly during thermal cycling of the resonator assembly. The clips are fabricated of a low thermal expansion material, such as molybdenum, which also has considerable yield strength after exposure to processing temperatures; the bonding of the clips to the edges of the resonator blank can be achieved by a polyimide containing electrically conductive particles.

  9. Delineating the Construct Network of the Personnel Reaction Blank: Associations with Externalizing Tendencies and Normal Personality

    ERIC Educational Resources Information Center

    Blonigen, Daniel M.; Patrick, Christopher J.; Gasperi, Marianna; Steffen, Benjamin; Ones, Deniz S.; Arvey, Richard D.; de Oliveira Baumgartl, Viviane; do Nascimento, Elizabeth

    2011-01-01

    Integrity testing has long been utilized in personnel selection to screen for tendencies toward counterproductive workplace behaviors. The construct of externalizing from the psychopathology literature represents a coherent spectrum marked by disinhibitory traits and behaviors. The present study drew on a sample of male and female undergraduates…

  10. 21 CFR 177.1950 - Vinyl chloride-ethylene copolymers.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... in cyclohexanone at 30 °C is not less than 0.50 deciliter per gram as determined by ASTM method D1243... copol-ymer per 100 grams of sample tested as determined from the organic chlorine content. The organic... extractives. All determinations shall be done in duplicate using duplicate blanks. Approximately 400 grams of...

  11. Replicating studies in which samples of participants respond to samples of stimuli.

    PubMed

    Westfall, Jacob; Judd, Charles M; Kenny, David A

    2015-05-01

    In a direct replication, the typical goal is to reproduce a prior experimental result with a new but comparable sample of participants in a high-powered replication study. Often in psychology, the research to be replicated involves a sample of participants responding to a sample of stimuli. In replicating such studies, we argue that the same criteria should be used in sampling stimuli as are used in sampling participants. Namely, a new but comparable sample of stimuli should be used to ensure that the original results are not due to idiosyncrasies of the original stimulus sample, and the stimulus sample must often be enlarged to ensure high statistical power. In support of the latter point, we discuss the fact that in experiments involving samples of stimuli, statistical power typically does not approach 1 as the number of participants goes to infinity. As an example of the importance of sampling new stimuli, we discuss the bygone literature on the risky shift phenomenon, which was almost entirely based on a single stimulus sample that was later discovered to be highly unrepresentative. We discuss the use of both resampled and expanded stimulus sets, that is, stimulus samples that include the original stimuli plus new stimuli. © The Author(s) 2015.

  12. Failure to Replicate a Genetic Association May Provide Important Clues About Genetic Architecture

    PubMed Central

    Greene, Casey S.; Penrod, Nadia M.; Williams, Scott M.; Moore, Jason H.

    2009-01-01

    Replication has become the gold standard for assessing statistical results from genome-wide association studies. Unfortunately this replication requirement may cause real genetic effects to be missed. A real result can fail to replicate for numerous reasons including inadequate sample size or variability in phenotype definitions across independent samples. In genome-wide association studies the allele frequencies of polymorphisms may differ due to sampling error or population differences. We hypothesize that some statistically significant independent genetic effects may fail to replicate in an independent dataset when allele frequencies differ and the functional polymorphism interacts with one or more other functional polymorphisms. To test this hypothesis, we designed a simulation study in which case-control status was determined by two interacting polymorphisms with heritabilities ranging from 0.025 to 0.4 with replication sample sizes ranging from 400 to 1600 individuals. We show that the power to replicate the statistically significant independent main effect of one polymorphism can drop dramatically with a change of allele frequency of less than 0.1 at a second interacting polymorphism. We also show that differences in allele frequency can result in a reversal of allelic effects where a protective allele becomes a risk factor in replication studies. These results suggest that failure to replicate an independent genetic effect may provide important clues about the complexity of the underlying genetic architecture. We recommend that polymorphisms that fail to replicate be checked for interactions with other polymorphisms, particularly when samples are collected from groups with distinct ethnic backgrounds or different geographic regions. PMID:19503614

  13. Influence of preconsolidation on consolidation quality after stamp forming of C/PEEK composites

    NASA Astrophysics Data System (ADS)

    Slange, T. K.; Warnet, L.; Grouve, W. J. B.; Akkerman, R.

    2016-10-01

    Stamp forming is a rapid manufacturing technology used to shape flat blanks of thermoplastic composite material into three-dimensional components. Currently, expensive autoclave and press consolidation are used to preconsolidate blanks. This study investigates the influence of preconsolidation on final consolidation quality after stamp forming and explores the potential of alternative blank manufacturing methods that could reduce part costs. Blanks were manufactured using various blank manufacturing methods and subsequently were stamp formed. The consolidation quality both before and after stamp forming was compared, where the focus was on void content as the main measure for consolidation quality. The void content was characterized through thickness and density measurements, as well as by microscopy analysis. Results indicate that preconsolidation quality does have an influence on the final consolidation quality. This is due to the severe deconsolidation and limited reconsolidation during stamp forming. Nevertheless, the potential of automated fiber placement and ultrasonic spot welding as alternative blank manufacturing methods was demonstrated.

  14. Guided episodic sampling for capturing and characterizing industrial plumes

    NASA Astrophysics Data System (ADS)

    Ou-Yang, Chang-Feng; Liao, Wei-Cheng; Chang, Chih-Chung; Hsieh, Hsin-Cheng; Wang, Jia-Lin

    2018-02-01

    An integrated sampling technique, dubbed trigger sampling, was developed to capture characteristic industrial emissions or plumes. In the field experiment, a hydrogen sulfide (H2S) analyzer was used as the triggering instrument at the boundary of a refinery plant due to frequent complaints of foul smell from local residents. Ten episodic samples were captured when the H2S level surpassed the prescribed trigger level of 8.5 ppbv over a three-day period. Three non-episodic (blank) samples and 23 road-side samples were also collected for comparison. All the 36 flask samples were analyzed by gas chromatography-mass spectrometry/flame ionization detection (GC-MS/FID) for 108 volatile organic compounds (VOCs). The total VOC abundance of the event samples was exceedingly higher than the non-episodic samples by over 80 times in the extreme case. Alkanes were found to be the dominant constituents in the event samples, amounting to over 90% of the total VOC concentrations vs. only 30-40% for the blank and metropolitan samples. In addition, light alkanes in the event samples were highly correlated with the trigger species H2S (R2 = 0.82), implying their common origin. The matrix of chemical composition vs. sample types permitted easy visualization of the dominance of light alkanes for the event samples compared to other types of samples. Principle component analysis (PCA) identified two major contributors to cover 93% of the total variance arising from the 36 samples, further quantifying the distinction of the triggered episodic samples from the contrast samples. The proposed trigger sampling is a coupling of fast-and-slow measurement techniques. In this example, the fast-response H2S analyzer served to "guide" sampling to capture industrial plumes which were then characterized by a relatively slow method of GC-MS/FID for detailed chemical composition representative of the prominent sources.

  15. Contamination analyses of technology mirror assembly optical surfaces

    NASA Technical Reports Server (NTRS)

    Germani, Mark S.

    1991-01-01

    Automated electron microprobe analyses were performed on tape lift samples from the Technology Mirror Assembly (TMA) optical surfaces. Details of the analyses are given, and the contamination of the mirror surfaces is discussed. Based on the automated analyses of the tape lifts from the TMA surfaces and the control blank, we can conclude that the particles identified on the actual samples were not a result of contamination due to the handling or sampling process itself and that the particles reflect the actual contamination on the surface of the mirror.

  16. Ultra-Low Level Plutonium Isotopes in the NIST SRM 4355A (Peruvian Soil-1)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Inn, Kenneth G.; LaRosa, Jerome; Nour, Svetlana

    2009-05-31

    For more than 20 years, countries and their agencies which monitor discharge sites and storage facilities have relied on the National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 4355 Peruvian Soil reference material. Its low fallout contamination makes it an ideal soil blank for measurements associated with terrestrial pathway to man studies. Presently, SRM 4355 is out of stock, and a new batch of the Peruvian soil is currently under development as future NIST SRM 4355A. Both environmental radioanalytical laboratories and mass spectrometry communities will benefit from this SRM. The former must assess their laboratory contamination andmore » measurement detection limits by measurement of blank sample material. The Peruvian Soil is so low in anthropogenic radionuclides that it is a suitable virtual blank. On the other hand, mass spectrometric laboratories have high sensitivity instruments that are capable of quantitative isotopic measurements at low plutonium levels of the SRM 4355 (first Peruvian Soil SRM) that provided the mass spectrometric community with the calibration, quality control, and testing material needed for methods development, and legal defensibility. The quantification of the ultra-low plutonium content in the SRM 4355A was a considerable challenge for the mass spectrometric laboratories. Careful blank control and correction, isobaric interferences, instrument stability, peak assessment, and detection assessment were necessary. Furthermore, a systematic statistical evaluation of the measurement results and considerable discussions with the mass spectroscopy metrologists were needed to derive the certified values and uncertainties. SRM 4355A will provide the mass spectrometric community with the quality control and testing material needed for higher sensitivity methods development, and legal defensibility.« less

  17. A Preliminary Evaluation of Near-Transducer Velocities Collected with Low-Blank Acoustic Doppler Current Profiler

    USGS Publications Warehouse

    Gartner, J.W.; Ganju, N.K.; ,

    2002-01-01

    Many streams and rivers for which the US Geological Survey must provide discharge measurements are too shallow to apply existing acoustic Doppler current profiler techniques for flow measurements of satisfactory quality. Because the same transducer is used for both transmitting and receiving acoustic signals in most Doppler current profilers, some small time delay is required for acoustic "ringing" to be damped out of transducers before meaningful measurements can be made. The result of that time delay is that velocity measurements cannot be made close to the transducer thus limiting the usefulness of these instruments in shallow regions. Manufacturers and users are constantly striving for improvements to acoustic instruments which would permit useful discharge measurements in shallow rivers and streams that are still often measured with techniques and instruments more than a century old. One promising area of advance appeared to be reduction of time delay (blank) required between transmitting and receiving signals during acoustic velocity measurements. Development of a low- or zero-blank transducer by RD Instruments3 held promise that velocity measurements could be made much closer to the transducer and thus in much shallower water. Initial experience indicates that this is not the case; limitation of measurement quality appears to be related to the physical presence of the transducer itself within the flow field. The limitation may be the result of changes to water flow pattern close to the transducer rather than transducer ringing characteristics as a function of blanking distance. Results of field experiments are discussed that support this conclusion and some minimum measurement distances from transducer are suggested based on water current speed and ADCP sample modes.

  18. The integrated water balance and soil data set of the Rollesbroich hydrological observatory

    NASA Astrophysics Data System (ADS)

    Qu, Wei; Bogena, Heye R.; Huisman, Johan A.; Schmidt, Marius; Kunkel, Ralf; Weuthen, Ansgar; Schiedung, Henning; Schilling, Bernd; Sorg, Jürgen; Vereecken, Harry

    2016-10-01

    The Rollesbroich headwater catchment located in western Germany is a densely instrumented hydrological observatory and part of the TERENO (Terrestrial Environmental Observatories) initiative. The measurements acquired in this observatory present a comprehensive data set that contains key hydrological fluxes in addition to important hydrological states and properties. Meteorological data (i.e., precipitation, air temperature, air humidity, radiation components, and wind speed) are continuously recorded and actual evapotranspiration is measured using the eddy covariance technique. Runoff is measured at the catchment outlet with a gauging station. In addition, spatiotemporal variations in soil water content and temperature are measured at high resolution with a wireless sensor network (SoilNet). Soil physical properties were determined using standard laboratory procedures from samples taken at a large number of locations in the catchment. This comprehensive data set can be used to validate remote sensing retrievals and hydrological models, to improve the understanding of spatial temporal dynamics of soil water content, to optimize data assimilation and inverse techniques for hydrological models, and to develop upscaling and downscaling procedures of soil water content information. The complete data set is freely available online (http://www.tereno.net, doi:10.5880/TERENO.2016.001, doi:10.5880/TERENO.2016.004, doi:10.5880/TERENO.2016.003) and additionally referenced by three persistent identifiers securing the long-term data and metadata availability.

  19. Ultra-low level plutonium isotopes in the NIST SRM 4355A (Peruvian Soil-1).

    PubMed

    Inn, Kenneth G W; LaRosa, Jerome; Nour, Svetlana; Brooks, George; LaMont, Steve; Steiner, Rob; Williams, Ross; Patton, Brad; Bostick, Debbie; Eiden, Gregory; Petersen, Steve; Douglas, Matthew; Beals, Donna; Cadieux, James; Hall, Greg; Goldberg, Steve; Vogt, Stephan

    2009-05-01

    For more than 20 years, countries and their agencies which monitor radionuclide discharge sites and storage facilities have relied on the National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 4355 Peruvian Soil. Its low fallout contamination makes it an ideal soil blank for measurements associated with terrestrial-pathway-to-man studies. Presently, SRM 4355 is out of stock, and a new batch of the Peruvian soil is currently under development as future NIST SRM 4355A. Both environmental radioanalytical laboratories and mass spectrometry communities will benefit from the use of this SRM. The former must assess their laboratory procedural contamination and measurement detection limits by measurement of blank sample material. The Peruvian Soil is so low in anthropogenic radionuclide content that it is a suitable virtual blank. On the other hand, mass spectrometric laboratories have high sensitivity instruments that are capable of quantitative isotopic measurements at low plutonium levels in the SRM 4355 (first Peruvian Soil SRM) that provided the mass spectrometric community with the calibration, quality control, and testing material needed for methods development and legal defensibility. The quantification of the ultra-low plutonium content in the SRM 4355A was a considerable challenge for the mass spectrometric laboratories. Careful blank control and correction, isobaric interferences, instrument stability, peak assessment, and detection assessment were necessary. Furthermore, a systematic statistical evaluation of the measurement results and considerable discussions with the mass spectroscopy metrologists were needed to derive the certified values and uncertainties. The one sided upper limit of the 95% tolerance with 95% confidence for the massic (239)Pu content in SRM 4355A is estimated to be 54,000 atoms/g.

  20. Tissue floaters and contaminants in the histology laboratory.

    PubMed

    Platt, Eric; Sommer, Paul; McDonald, Linda; Bennett, Ana; Hunt, Jennifer

    2009-06-01

    Anatomic pathology diagnosis is often based on morphologic features. In recent years, an appropriate increased attention to patient safety has led to an emphasis on improving maintenance of patient identity. Decreasing or eliminating cross-contamination from one specimen to another is an example of a patient identity issue for which process improvement can be initiated. To quantify the presence of cross-contamination from histology water baths and the slide stainers. We assessed for the presence of contaminants in water baths at cutting stations and in linear stainer stain baths. We assessed the potential for tissue discohesion and carryover in tissue samples and we assessed the potential for carryover onto blank slides sent through the stainer. In the 13 water baths examined (totalling 195 L of water), only one fragment of tissue was identified. The stain baths, however, contained abundant tissue contaminants, ranging in size from 2 to 3 cells to hundreds of cells. The first sets of xylenes and alcohols were the most heavily contaminated. Cross-contamination to blank slides occurred at a rate of 8%, with the highest frequency in the late afternoon. Cross-contamination can present a significant challenge in the histology laboratory. Although the histotechnologists' water baths are not heavily contaminated, the stainer baths do contain contaminating tissue fragments. Cross-contamination does occur onto blank slides in the experimental setting.

  1. 3D finite element modelling of sheet metal blanking process

    NASA Astrophysics Data System (ADS)

    Bohdal, Lukasz; Kukielka, Leon; Chodor, Jaroslaw; Kulakowska, Agnieszka; Patyk, Radoslaw; Kaldunski, Pawel

    2018-05-01

    The shearing process such as the blanking of sheet metals has been used often to prepare workpieces for subsequent forming operations. The use of FEM simulation is increasing for investigation and optimizing the blanking process. In the current literature a blanking FEM simulations for the limited capability and large computational cost of the three dimensional (3D) analysis has been largely limited to two dimensional (2D) plane axis-symmetry problems. However, a significant progress in modelling which takes into account the influence of real material (e.g. microstructure of the material), physical and technological conditions can be obtained by using 3D numerical analysis methods in this area. The objective of this paper is to present 3D finite element analysis of the ductile fracture, strain distribution and stress in blanking process with the assumption geometrical and physical nonlinearities. The physical, mathematical and computer model of the process are elaborated. Dynamic effects, mechanical coupling, constitutive damage law and contact friction are taken into account. The application in ANSYS/LS-DYNA program is elaborated. The effect of the main process parameter a blanking clearance on the deformation of 1018 steel and quality of the blank's sheared edge is analyzed. The results of computer simulations can be used to forecasting quality of the final parts optimization.

  2. Groundwater-quality data in 12 GAMA study units: Results from the 2006–10 initial sampling period and the 2008–13 trend sampling period, California GAMA Priority Basin Project

    USGS Publications Warehouse

    Mathany, Timothy M.

    2017-03-09

    The Priority Basin Project (PBP) of the Groundwater Ambient Monitoring and Assessment (GAMA) program was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey in cooperation with the California State Water Resources Control Board. From 2004 through 2012, the GAMA-PBP collected samples and assessed the quality of groundwater resources that supply public drinking water in 35 study units across the State. Selected sites in each study unit were sampled again approximately 3 years after initial sampling as part of an assessment of temporal trends in water quality by the GAMA-PBP. Twelve of the study units, initially sampled during 2006–11 (initial sampling period) and sampled a second time during 2008–13 (trend sampling period) to assess temporal trends, are the subject of this report.The initial sampling was designed to provide a spatially unbiased assessment of the quality of untreated groundwater used for public water supplies in the 12 study units. In these study units, 550 sampling sites were selected by using a spatially distributed, randomized, grid-based method to provide spatially unbiased representation of the areas assessed (grid sites, also called “status sites”). After the initial sampling period, 76 of the previously sampled status sites (approximately 10 percent in each study unit) were randomly selected for trend sampling (“trend sites”). The 12 study units sampled both during the initial sampling and during the trend sampling period were distributed among 6 hydrogeologic provinces: Coastal (Northern and Southern), Transverse Ranges and Selected Peninsular Ranges, Klamath, Modoc Plateau and Cascades, and Sierra Nevada Hydrogeologic Provinces. For the purposes of this trend report, the six hydrogeologic provinces were grouped into two hydrogeologic regions based on location: Coastal and Mountain.The groundwater samples were analyzed for a number of synthetic organic constituents (volatile organic compounds, pesticides, and pesticide degradates), constituents of special interest (perchlorate and 1,2,3-trichloropropane), and natural inorganic constituents (nutrients, major and minor ions, and trace elements). Isotopic tracers (tritium, carbon-14, and stable isotopes of hydrogen and oxygen in water) also were measured to help identify processes affecting groundwater quality and the sources and ages of the sampled groundwater. More than 200 constituents and water-quality indicators were measured during the trend sampling period.Quality-control samples (blanks, replicates, matrix-spikes, and surrogate compounds) were collected at about one-third of the trend sites, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. On the basis of detections in laboratory and field blank samples collected by GAMA-PBP study units, including the 12 study units presented here, reporting levels for some groundwater results were adjusted in this report. Differences between replicate samples were mostly within acceptable ranges, indicating low variability in analytical results. Matrix-spike recoveries were largely within the acceptable range (70 to 130 percent).This study did not attempt to evaluate the quality of water delivered to consumers. After withdrawal, groundwater used for drinking water typically is treated, disinfected, and blended with other waters to achieve acceptable water quality. The comparison benchmarks used in this report apply to treated water that is served to the consumer, not to untreated groundwater. To provide some context for the results, however, concentrations of constituents measured in these groundwater samples were compared with benchmarks established by the U.S. Environmental Protection Agency and the State of California. Comparisons between data collected for this study and benchmarks for drinking water are for illustrative purposes only and are not indicative of compliance or non-compliance with those benchmarks.Most organic constituents that were detected in groundwater samples from the trend sites were found at concentrations less than health-based benchmarks. One volatile organic compound—perchloroethene—was detected at a concentration greater than the health-based benchmark in samples from one trend site during the initial and trend sampling periods. Chloroform was detected in at least 10 percent of the samples at trend sites in both sampling periods. Methyl tert-butyl ether was detected in samples from more than 10 percent of the trend sites during the initial sampling period. No pesticide or pesticide degradate was detected in greater than 10 percent of the samples from trend sites or at concentrations greater than their health-based benchmarks during either sampling period. Nutrients were not detected at concentrations greater than their health-based benchmarks during either sampling period.Most detections of major ions and trace elements in samples from trend sites were less than health-based benchmarks during both sampling periods. Arsenic and boron each were detected at concentrations greater than the health-based benchmark in samples from four trend sites during the initial and trend sampling periods. Molybdenum was detected in samples from four trend sites at concentrations greater than the health-based benchmark during both sampling periods. Samples from two of these trend sites had similar molybdenum concentrations, and two had substantially different concentrations during the initial and trend sampling periods. Uranium was detected at a concentration greater than the health-based benchmark only at two trend sites.

  3. Characterization and application of a diamine oxidase from Lathyrus sativus as component of an electrochemical biosensor for the determination of biogenic amines in wine and beer.

    PubMed

    Di Fusco, Massimo; Federico, Rodolfo; Boffi, Alberto; Macone, Alberto; Favero, Gabriele; Mazzei, Franco

    2011-08-01

    In this work, we have characterized a diamine oxidase (DAO) from Lathyrus sativus and evaluated its use, for the first time, as biocatalytic component of an electrochemical biosensor for the determination of biogenic amines index in wine and beer samples. Firstly, DAO was electrokinetically characterized free in solution by means of a platinum electrode and then immobilized by using polyazetidine prepolimer on the surface of screen-printed electrodes constituted of two gold working electrodes. The amperometric measurements were carried out by using a flow system at a fixed potential of +600 mV vs the internal silver pseudo reference in phosphate buffer solution (0.1 mol l(-1), pH = 7.4). The analysis of wine and beer samples were performed in flow injection system using the dual channel transducer providing simultaneous detection of sample and blank signal, and the resulting signal (after subtraction of the blank signal) was referred to that of putrescine. The results were compared with those obtained using a modified reference method based on gas chromatography-mass spectrometry analysis on the same samples. The results obtained in the analysis of Italian wines shows the better suitability of DAO-based biosensor in the determination of the biogenic amines (BAs) index expressed as putrescine equivalent in both red and white wines, being less efficient in beer samples where it underestimates by about 50% the BAs content.

  4. External Quality Assurance Programs Managed by the U.S. Geological Survey in Support of the National Atmospheric Deposition Program/Mercury Deposition Network

    USGS Publications Warehouse

    Latysh, Natalie E.; Wetherbee, Gregory A.

    2007-01-01

    The U.S. Geological Survey (USGS) Branch of Quality Systems operates external quality assurance programs for the National Atmospheric Deposition Program/Mercury Deposition Network (NADP/MDN). Beginning in 2004, three programs have been implemented: the system blank program, the interlaboratory comparison program, and the blind audit program. Each program was designed to measure error contributed by specific components in the data-collection process. The system blank program assesses contamination that may result from sampling equipment, field exposure, and routine handling and processing of the wet-deposition samples. The interlaboratory comparison program evaluates bias and precision of analytical results produced by the Mercury Analytical Laboratory (HAL) for the NADP/MDN, operated by Frontier GeoSciences, Inc. The HAL's performance is compared with the performance of five other laboratories. The blind audit program assesses bias and variability of MDN data produced by the HAL using solutions disguised as environmental samples to ascertain true laboratory performance. This report documents the implementation of quality assurance procedures for the NADP/MDN and the operating procedures for each of the external quality assurance programs conducted by the USGS. The USGS quality assurance information provides a measure of confidence to NADP/MDN data users that measurement variability is distinguished from environmental signals.

  5. 47 CFR 73.646 - Telecommunications Service on the Vertical Blanking Interval and in the Visual Signal.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 4 2013-10-01 2013-10-01 false Telecommunications Service on the Vertical Blanking Interval and in the Visual Signal. 73.646 Section 73.646 Telecommunication FEDERAL COMMUNICATIONS....646 Telecommunications Service on the Vertical Blanking Interval and in the Visual Signal. (a...

  6. Three-dimensional characterization of extreme ultraviolet mask blank defects by interference contrast photoemission electron microscopy.

    PubMed

    Lin, Jingquan; Weber, Nils; Escher, Matthias; Maul, Jochen; Han, Hak-Seung; Merkel, Michael; Wurm, Stefan; Schönhense, Gerd; Kleineberg, Ulf

    2008-09-29

    A photoemission electron microscope based on a new contrast mechanism "interference contrast" is applied to characterize extreme ultraviolet lithography mask blank defects. Inspection results show that positioning of interference destructive condition (node of standing wave field) on surface of multilayer in the local region of a phase defect is necessary to obtain best visibility of the defect on mask blank. A comparative experiment reveals superiority of the interference contrast photoemission electron microscope (Extreme UV illumination) over a topographic contrast one (UV illumination with Hg discharge lamp) in detecting extreme ultraviolet mask blank phase defects. A depth-resolved detection of a mask blank defect, either by measuring anti-node peak shift in the EUV-PEEM image under varying inspection wavelength condition or by counting interference fringes with a fixed illumination wavelength, is discussed.

  7. Method for forming a liquid cooled airfoil for a gas turbine

    DOEpatents

    Grondahl, Clayton M.; Willmott, Leo C.; Muth, Myron C.

    1981-01-01

    A method for forming a liquid cooled airfoil for a gas turbine is disclosed. A plurality of holes are formed at spaced locations in an oversized airfoil blank. A pre-formed composite liquid coolant tube is bonded into each of the holes. The composite tube includes an inner member formed of an anti-corrosive material and an outer member formed of a material exhibiting a high degree of thermal conductivity. After the coolant tubes have been bonded to the airfoil blank, the airfoil blank is machined to a desired shape, such that a portion of the outer member of each of the composite tubes is contiguous with the outer surface of the machined airfoil blank. Finally, an external skin is bonded to the exposed outer surface of both the machined airfoil blank and the composite tubes.

  8. Seeing Red and Shooting Blanks: Study of Red Quasars and Blank X-Ray Sources

    NASA Technical Reports Server (NTRS)

    Oliversen, Ronald (Technical Monitor); Elvis, Martin

    2005-01-01

    A major paper describing the technique and providing a list of 'blanks' was published in the Astrophysical Journal (abstract below). The results revealed a fascinating trove of novel X-ray sources: high redshift clusters of galaxies found efficiently; X-ray absorbed, optically clean AGN, which may be the bright prototypes of Chandra Deep Survey sources; and several with a still unknown nature. Recent XMM-Newton results confirm the existence of this class of X-ray source with much refined positions. During the first year of this project we have made a major discovery. The second 'blanks' X-ray source observed with Chandra was found to be extended. Using Chandra data and ground-based R and K band imaging we estimated this to be a high redshift cluster of galaxies with z approx. 0.85. Spectroscopy agrees with this estimate (z=0.89). This success shows that our method of hunting down 'blank' field X-ray sources is a highly efficient method of finding the otherwise elusive high redshift clusters. With extensive follow-up we should be able to use 'blanks' to make cosmological tests. The paper is now in press in the Astrophysical Journal (abstract below.) The other Chandra source is point-like, showing that there are a variety of 'blank' source types. Other follow-up observations with XMM-Newton, and (newly approved in cycle 2) with Chandra are eagerly awaited. A follow-up paper uses a large amount of supporting data for the remaining blanks. A combination of ROSAT, Chandra and ground based data convincingly identified one of the blanks as a Ultra-luminous X-ray source (ULX) in a spiral galaxy (abstract below). This program resulted in 3 refereed papers in major journals, 4 conference proceedings and a significant fraction of the PhD thesis of Dr. Ilaria Cagnoni. Details of the publications are given.

  9. Seeing Red and Shooting Blanks: A Study of Red Quasars and Blank Field X-Ray Sources

    NASA Technical Reports Server (NTRS)

    Elvis, Martin; Oliversen, Ronald J. (Technical Monitor)

    2002-01-01

    We have identified a population of 'blank field sources' (or 'blanks') among the ROSAT (Roentgen Satellite) bright unidentified X-ray sources with faint optical counterparts. The extreme X-ray over optical flux ratio of blank field sources is not compatible with the main classes of X-ray emitters except for extreme BL Lacertae objects at fx/fv is equal to or less than 35. From the analysis of ROSAT archival data we found evidence for only three sources, out of 16, needing absorption in excess of the Galactic value and no indication of variability. We also found evidence for an extended nature for only one of the five blanks with a serendipitous HRI (High Resolution Imager) detection; this source (1WGA J1226.9+3332) was confirmed as a z=0.89 cluster of galaxies. Palomar images reveal the presence of a red (O - E is equal to or greater than 2) counterpart in the X-ray error circle for six blanks. The identification process brought to the discovery of another high z cluster of galaxies, one (possibly extreme) BL Lac and two apparently normal type 1 AGNs (Active Galactic Nuclei). These AGNs, together with four more AGN-like objects seem to form a well defined group: they present type 1 X-ray spectra but red Palomar counterparts. We discuss the possible explanations for the discrepancy between the X-ray and optical data, among which: a suppressed big blue bump emission, an extreme dust to gas (approximately 40 - 60 the Galactic ratio) ratio value and a high redshift (z is greater than or equal to 3.5) QSO (Quasi-Stellar Object) nature. These AGN-like blanks seem to be the bright (and easier to study) analogs of the sources which are being found in deep Chandra observations. Five more blanks have a still an unknown nature.

  10. Purgeable organic compounds in ground water at the Idaho National Engineering Laboratory, Idaho; 1988 and 1989

    USGS Publications Warehouse

    Mann, L.J.

    1990-01-01

    Groundwater samples from 38 wells at the Idaho National Engineering Laboratory were analyzed for 36 purgeable organic compounds in 1988-89. Thirty-six of the wells obtain water from the Snake River Plain aquifer and were equipped with dedicated or portable pumps. Water samples from one well that obtains water from the aquifer and one that obtains water from a perched groundwater zone were collected using a thief sampler. Analyses of water from 22 wells indicated the aquifer locally contained detectable concentrations of at least 1 of 19 purgeable organic compounds, mainly carbon tetrachloride, 1,1,1-trichloroethane, and trichloroethylene. Except for five wells, the maximum concentration of a specific compound in groundwater was 6.4 microgram/L or less; concentrations of most compounds were less than 0.2 microgram/L. Water from four wells at and near the Test Area North contained from 44 to 29, 000 micrograms/L of trichloroethylene. Water from a well that obtains water from a discontinuous perched groundwater zone at the Radioactive Waste Management Complex contained 1,400 micrograms/L of carbon tetrachloride, 940 micrograms/L of chloroform, 250 micrograms/L of 1,1,1- trichloroethane, and 1,100 micrograms/L trichloroethylene. Selected purgeable organic compounds, such as total xylene and methylene chloride, were detected in some groundwater samples and some blank samples consisting of boiled deionized water. Their presence in the blank samples suggest the compounds could have been inadvertently introduced into the groundwater sampled during or subsequent to collection. (USGS)

  11. Three Conceptual Replication Studies in Group Theory

    ERIC Educational Resources Information Center

    Melhuish, Kathleen

    2018-01-01

    Many studies in mathematics education research occur with a nonrepresentative sample and are never replicated. To challenge this paradigm, I designed a large-scale study evaluating student conceptions in group theory that surveyed a national, representative sample of students. By replicating questions previously used to build theory around student…

  12. SEMATECH produces defect-free EUV mask blanks: defect yield and immediate challenges

    NASA Astrophysics Data System (ADS)

    Antohe, Alin O.; Balachandran, Dave; He, Long; Kearney, Patrick; Karumuri, Anil; Goodwin, Frank; Cummings, Kevin

    2015-03-01

    Availability of defect-free reflective mask has been one of the most critical challenges to extreme ultraviolet lithography (EUVL). To mitigate the risk, significant progress has been made on defect detection, pattern shifting, and defect repair. Clearly such mitigation strategies are based on the assumption that defect counts and sizes from incoming mask blanks must be below practical levels depending on mask specifics. The leading industry consensus for early mask product development is that there should be no defects greater than 80 nm in the quality area, 132 mm x 132 mm. In addition less than 10 defects smaller than 80 nm may be mitigable. SEMATECH has been focused on EUV mask blank defect reduction using Veeco Nexus TM IBD platform, the industry standard for mask blank production, and assessing if IBD technology can be evolved to a manufacturing solution. SEMATECH has recently announced a breakthrough reduction of defects in the mask blank deposition process resulting in the production of two defect-free EUV mask blanks at 54 nm inspection sensitivity (SiO2 equivalent). This paper will discuss the dramatic reduction of baseline EUV mask blank defects, review the current deposition process run and compare results with previous process runs. Likely causes of remaining defects will be discussed based on analyses as characterized by their compositions and whether defects are embedded in the multilayer stack or non-embedded.

  13. When the Ostrich-Algorithm Fails: Blanking Method Affects Spike Train Statistics.

    PubMed

    Joseph, Kevin; Mottaghi, Soheil; Christ, Olaf; Feuerstein, Thomas J; Hofmann, Ulrich G

    2018-01-01

    Modern electroceuticals are bound to employ the usage of electrical high frequency (130-180 Hz) stimulation carried out under closed loop control, most prominent in the case of movement disorders. However, particular challenges are faced when electrical recordings of neuronal tissue are carried out during high frequency electrical stimulation, both in-vivo and in-vitro . This stimulation produces undesired artifacts and can render the recorded signal only partially useful. The extent of these artifacts is often reduced by temporarily grounding the recording input during stimulation pulses. In the following study, we quantify the effects of this method, "blanking," on the spike count and spike train statistics. Starting from a theoretical standpoint, we calculate a loss in the absolute number of action potentials, depending on: width of the blanking window, frequency of stimulation, and intrinsic neuronal activity. These calculations were then corroborated by actual high signal to noise ratio (SNR) single cell recordings. We state that, for clinically relevant frequencies of 130 Hz (used for movement disorders) and realistic blanking windows of 2 ms, up to 27% of actual existing spikes are lost. We strongly advice cautioned use of the blanking method when spike rate quantification is attempted. Blanking (artifact removal by temporarily grounding input), depending on recording parameters, can lead to significant spike loss. Very careful use of blanking circuits is advised.

  14. When the Ostrich-Algorithm Fails: Blanking Method Affects Spike Train Statistics

    PubMed Central

    Joseph, Kevin; Mottaghi, Soheil; Christ, Olaf; Feuerstein, Thomas J.; Hofmann, Ulrich G.

    2018-01-01

    Modern electroceuticals are bound to employ the usage of electrical high frequency (130–180 Hz) stimulation carried out under closed loop control, most prominent in the case of movement disorders. However, particular challenges are faced when electrical recordings of neuronal tissue are carried out during high frequency electrical stimulation, both in-vivo and in-vitro. This stimulation produces undesired artifacts and can render the recorded signal only partially useful. The extent of these artifacts is often reduced by temporarily grounding the recording input during stimulation pulses. In the following study, we quantify the effects of this method, “blanking,” on the spike count and spike train statistics. Starting from a theoretical standpoint, we calculate a loss in the absolute number of action potentials, depending on: width of the blanking window, frequency of stimulation, and intrinsic neuronal activity. These calculations were then corroborated by actual high signal to noise ratio (SNR) single cell recordings. We state that, for clinically relevant frequencies of 130 Hz (used for movement disorders) and realistic blanking windows of 2 ms, up to 27% of actual existing spikes are lost. We strongly advice cautioned use of the blanking method when spike rate quantification is attempted. Impact statement Blanking (artifact removal by temporarily grounding input), depending on recording parameters, can lead to significant spike loss. Very careful use of blanking circuits is advised. PMID:29780301

  15. Laser: a tool for light weight steel solutions for the automotive industry

    NASA Astrophysics Data System (ADS)

    Prange, Wilfried; Wonneberger, Ingo

    2003-03-01

    Mid 80th the steel industry discovered the laser as a tool to develop new products made from steel -- the tailored blanks. That means welding single blanks together, which are of different gauge or grades and coating. In the meantime this product is one of the key solutions for light weight vehicles with increasing performances. The market development world wide confirms this statement. But the development of this product is still going on. New high power lasers and new laser generations as Nd:YAG lasers are the basis. Today welded blanks with almost any seam/blank configuration are in high volume production. These blanks offer an additional potential for the optimization of the final product. To produce flat blank is only one possibility. New developments are the tailored tubes as a prematerial for the hydroforming process. This product becomes more and more important for optimized body in white solutions. But this design elements need new solutions in the assembly shops. So the laser is going to get more importance in the 3D welding process as well. This was shown for example in the ULSAB(-AVC)-project. Future vehicles more and more contain different materials. For example the joining of steel and aluminum to Hybrid Blanks can be done successfully by the use of laser. So the laser is one of the most important tools in the future.

  16. NHEXAS PHASE I REGION 5 STUDY--QA ANALYTICAL RESULTS FOR VOCS IN REPLICATES

    EPA Science Inventory

    This data set includes analytical results for measurements of VOCs in 204 duplicate (replicate) samples. Measurements were made for up to 23 VOCs in samples of air, water, and blood. Duplicate samples (samples collected along with or next to the original samples) were collected t...

  17. NHEXAS PHASE I REGION 5 STUDY--QA ANALYTICAL RESULTS FOR METALS IN REPLICATES

    EPA Science Inventory

    This data set includes analytical results for measurements of metals in 490 duplicate (replicate) samples and for particles in 130 duplicate samples. Measurements were made for up to 11 metals in samples of air, dust, water, blood, and urine. Duplicate samples (samples collected ...

  18. Low-Cost Opportunity for Small-Scale Manufacture of Hardwood Blanks

    Treesearch

    Bruce G. Hansen; Philip A. Araman

    1985-01-01

    We analyzed the manufacture of standard-size hardwood blanks from lumber on a relatively small scale by conventional processing. Requiring an investment of just over $200,000, the conventional mill can process 500 M bf (thousand board feet) of kiln-dried lumber annually. The study focused on the economics associated with manufacture of blanks from four species -...

  19. 76 FR 14697 - Aleris Blanking and Rim Products, Inc., a Division of Aleris International, Inc., Terre Haute, IN...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-17

    ... Products, Inc., a Division of Aleris International, Inc., Terre Haute, IN; Notice of Revised Determination... workers of Aleris Blanking and Rim Products, Inc., a division of Aleris International, Inc., Terre Haute... Blanking and Rim Products, Inc., a division of Aleris International, Inc., Terre Haute, Indiana, who became...

  20. Analysis of Duplicated Multiple-Samples Rank Data Using the Mack-Skillings Test.

    PubMed

    Carabante, Kennet Mariano; Alonso-Marenco, Jose Ramon; Chokumnoyporn, Napapan; Sriwattana, Sujinda; Prinyawiwatkul, Witoon

    2016-07-01

    Appropriate analysis for duplicated multiple-samples rank data is needed. This study compared analysis of duplicated rank preference data using the Friedman versus Mack-Skillings tests. Panelists (n = 125) ranked twice 2 orange juice sets: different-samples set (100%, 70%, vs. 40% juice) and similar-samples set (100%, 95%, vs. 90%). These 2 sample sets were designed to get contrasting differences in preference. For each sample set, rank sum data were obtained from (1) averaged rank data of each panelist from the 2 replications (n = 125), (2) rank data of all panelists from each of the 2 separate replications (n = 125 each), (3) jointed rank data of all panelists from the 2 replications (n = 125), and (4) rank data of all panelists pooled from the 2 replications (n = 250); rank data (1), (2), and (4) were separately analyzed by the Friedman test, although those from (3) by the Mack-Skillings test. The effect of sample sizes (n = 10 to 125) was evaluated. For the similar-samples set, higher variations in rank data from the 2 replications were observed; therefore, results of the main effects were more inconsistent among methods and sample sizes. Regardless of analysis methods, the larger the sample size, the higher the χ(2) value, the lower the P-value (testing H0 : all samples are not different). Analyzing rank data (2) separately by replication yielded inconsistent conclusions across sample sizes, hence this method is not recommended. The Mack-Skillings test was more sensitive than the Friedman test. Furthermore, it takes into account within-panelist variations and is more appropriate for analyzing duplicated rank data. © 2016 Institute of Food Technologists®

  1. [Protection and bidirectional effect of rhubarb anthraquinone and tannins for rats' liver].

    PubMed

    Qin, Lu-shan; Zhao, Hai-ping; Zhao, Yan-ling; Ma, Zhi-jiel; Zeng, Ling-na; Zhang, Ya-ming; Zhang, Ping; Yan, Dan; Bai, Zhao-fang; Li, Yue; Hao, Qing-xiu; Zhao, Kui-jun; Wang, Jia-bo; Xiao, Xiao-he

    2014-06-01

    To compare the bidirectional effect of rhubarb total anthraquinone (TA) and total tannins (TT) on rats' liver. One hundred rats were randomly divided into 10 groups, i.e., the blank group, the model group, the blank + high dose TA group, the blank +low dose TA group, the blank + high dose TT group, the blank + low dose TT group, the model + high dose TA group, the model + low dose TA group, the model +high dose TT group, and the model + low dose TT group, 10 in each group. The carbon tetrachloride (CCI4) was used to prepare the acute liver injury rat model. TA and TT of rhubarb (at 5.40 g crude drugs/kg and 14.69 g crude drugs/kg) were intragastrically administrated to rats in all groups except the blank group and the model group, once daily for 6 successive days.The general state of rats, biochemical indices such as alanine aminotransferase (ALT), aspartate aminotransferase (AST), alkaline phosphatase (ALP), laminin (LN), hyaluronic acid (HA), transforming growth factor beta1 (TGF-beta1), as well pathological results of rat liver tissues. Finally the protection laws of TA and TT for rats' liver were analyzed using factor analysis. Compared with the blank control group, all biochemical indices increased in the blank group (P < 0.05, P < 0.01). HA also increased in the blank + high dose TA group; AST, ALT, and HA also increased in the blank +high dose TT group (P < 0.05). Compared with the model group, AST, ALT, ALP, HA, and TGF-beta1 significantly decreased in the model + low dose TA group, the model + high dose TA group, the model + low dose TT group (P < 0.05, P < 0.01). Serum AST, ALT, and ALP also decreased in the model + high dose TT group (P < 0.05, P < 0.01). Pathological results showed that mild swollen liver cells in the model + high dose TA group. Fatty degeneration and fragmental necrosis around the central veins occurred in the blank + high dose TA group. The pathological injury was inproved in the model +low dose TA group. Two common factors, liver fibrosis and liver cell injury, were extracted by using factor analysis. TA showed stronger improvement of the two common factors than TT. Rhubarb TA and TT showed protective and harmful effects on rats' liver. At an equivalent dosage, TA had better liver protection than TT. High dose TT played a role in liver injury to some extent.

  2. The standard calibration instrument automation system for the atomic absorption spectrophotometer. Part 3: Program documentation

    NASA Astrophysics Data System (ADS)

    Ryan, D. P.; Roth, G. S.

    1982-04-01

    Complete documentation of the 15 programs and 11 data files of the EPA Atomic Absorption Instrument Automation System is presented. The system incorporates the following major features: (1) multipoint calibration using first, second, or third degree regression or linear interpolation, (2) timely quality control assessments for spiked samples, duplicates, laboratory control standards, reagent blanks, and instrument check standards, (3) reagent blank subtraction, and (4) plotting of calibration curves and raw data peaks. The programs of this system are written in Data General Extended BASIC, Revision 4.3, as enhanced for multi-user, real-time data acquisition. They run in a Data General Nova 840 minicomputer under the operating system RDOS, Revision 6.2. There is a functional description, a symbol definitions table, a functional flowchart, a program listing, and a symbol cross reference table for each program. The structure of every data file is also detailed.

  3. Stiffness management of sheet metal parts using laser metal deposition

    NASA Astrophysics Data System (ADS)

    Bambach, Markus; Sviridov, Alexander; Weisheit, Andreas

    2017-10-01

    Tailored blanks are established solutions for the production of load-adapted sheet metal components. In the course of the individualization of production, such semi-finished products are gaining importance. In addition to tailored welded blanks and tailored rolled blanks, patchwork blanks have been developed which allow a local increase in sheet thickness by welding, gluing or soldering patches onto sheet metal blanks. Patchwork blanks, however, have several limitations, on the one hand, the limited freedom of design in the production of patchwork blanks and, on the other hand, the fact that there is no optimum material bonding with the substrate. The increasing production of derivative and special vehicles on the basis of standard vehicles, prototype production and the functionalization of components require solutions with which semi-finished products and sheet metal components can be provided flexibly with local thickenings or functional elements with a firm metallurgical bond to the substrate. An alternative to tailored and patchwork blanks is, therefore, a free-form reinforcement applied by additive manufacturing via laser metal deposition (LMD). By combining metal forming and additive manufacturing, stiffness can be adapted to the loads based on standard components in a material-efficient manner and without the need to redesign the forming tools. This paper details a study of the potential of stiffness management by LMD using a demonstrator part. Sizing optimization is performed and part distortion is taken into account to find an optimal design for the cladding. A maximum stiffness increase of 167% is feasible with only 4.7% additional mass. Avoiding part distortion leads to a pareto-optimal design which achieves 95% more stiffness with 6% added mass.

  4. [Susceptibility of Trichogramma pretiosum Riley (Hymenoptera: Trichogrammatidae) adults to fungicides used to control apple diseases].

    PubMed

    Manzon, Cristiane G; Grützmacher, Anderson D; Giolo, Fabrizio P; de Lima, Crislaine A B Lima; Nörnberg, Sandro D; Müller, Cristiane; da R Härter, Wagner

    2006-01-01

    This study evaluated the susceptibility under laboratory conditions of Trichogrammapretiosum Riley adults to fungicides recommended by the Integrated Production of Apple (IPA). The bioassays were carried out using the International Organization for Biological Control (IOBC), West Palearctic Regional Section (WPRS) standard protocols. Twelve selected fungicides were studied in the doses (g or ml active ingredient/100 L) captan 1 (0.115), captan 2 (0.120), kresoxim-methyl (0.010), sulphur 1 (AG) (0.480), sulphur 2 (0.480), folpet (0.105), mancozeb (0.160), pyraclostrobin (0.010), tebuconazole (0.010), tetraconazole (0.005), thiophanate-methyl (0.050) and triforine (0.024). Distilled water was used as the blank treatment and the insecticide triclorfon (0.150) as a positive control. The parasitoids were exposed to dry residues applied on glass plates. The reduction in the capacity of parasitism was used to measure the effect of the chemical in comparison to the blank treatment. Each treatment was replicated four times. The results allowed us to classify the fungicides tested in four categories: 1, harmless (< 30%); 2, slightly harmful (30-79%); 3, moderately harmful (80-99%); and 4, harmful (> 99%). 75% of the tested substances were classified as selective (classes 1 and 2) to the parasitoid. The fungicides captan 1, captan 2, kresoxim-methyl, folpet, pyraclostrobin, tebuconazole, thiophanate-methyl and triforine were harmless; mancozeb was slightly harmful; sulphur 1 (AG) and tetraconazole were moderately harmful and sulphur 2 was harmful. These findings should be taken into account when selecting fungicides to spray apple orchards against fungi diseases to preserve the egg parasitoid T. pretiosum.

  5. Blanking and piercing theory, applications and recent experimental results

    NASA Astrophysics Data System (ADS)

    Zaid, Adnan l. O.

    2014-06-01

    Blanking and piercing are manufacturing processes by which certain geometrical shapes are sheared off a sheet metal. If the sheared off part is the one required, the processes referred to as blanking and if the remaining part in the sheet is the one required, the process is referred to as piercing. In this paper, the theory and practice of these processes are reviewed and discussed The main parameters affecting these processes are presented and discussed. These include: the radial clearance percentage, punch and die geometrical parameters, for example punch and die profile radii. The abovementioned parameters on the force and energy required to effect blanking together with their effect on the quality of the products are also presented and discussed. Recent experimental results together with photomacrographs and photomicrographs are also included and discussed. Finally, the effect of punch and die wear on the quality of the blanks is alsogiven and discussed.

  6. Performance characteristics of an automated gas chromatograph-ion trap mass spectrometer system used for the 1995 Southern Oxidants Study field investigation in Nashville, Tennessee

    NASA Astrophysics Data System (ADS)

    Daughtrey, E. Hunter; Adams, Jeffrey R.; Oliver, Karen D.; Kronmiller, Keith G.; McClenny, William A.

    1998-09-01

    A trailer-deployed automated gas chromatograph-mass spectrometer (autoGC-MS) system capable of making continuous hourly measurements was used to determine volatile organic compounds (VOCs) in ambient air at New Hendersonville, Tennessee, and Research Triangle Park, North Carolina, in 1995. The system configuration, including the autoGC-MS, trailer and transfer line, siting, and sampling plan and schedule, is described. The autoGC-MS system employs a pair of matched sorbent traps to allow simultaneous sampling and desorption. Desorption is followed by Stirling engine cryofocusing and subsequent GC separation and mass spectral identification and quantification. Quality control measurements described include evaluating precision and accuracy of replicate analyses of independently supplied audit and round-robin canisters and determining the completeness of the data sets taken in Tennessee. Data quality objectives for precision (±10%) and accuracy (±20%) of 10- to 20-ppbv audit canisters and a completeness of >75% data capture were met. Quality assurance measures used in reviewing the data set include retention time stability, calibration checks, frequency distribution checks, and checks of the mass spectra. Special procedures and tests were used to minimize sorbent trap artifacts, to verify the quality of a standard prepared in our laboratory, and to prove the integrity of the insulated, heated transfer line. A rigorous determination of total system blank concentration levels using humidified scientific air spiked with ozone allowed estimation of method detection limits, ranging from 0.01 to 1.0 ppb C, for most of the 100 target compounds, which were a composite list of the target compounds for the Photochemical Assessment Monitoring Station network, those for Environmental Protection Agency method TO-14, and selected oxygenated VOCs.

  7. Solid Phase Extraction of Trace Elements in Waterand Tissue Samples on a Mini Column with Diphenylcarbazone Impregnated Nano-TiO2 and Their Determination by Inductively Coupled Plasma Optical Emission Spectrometry

    PubMed Central

    Baytak, Sıtkı; Arslan, Zikri

    2015-01-01

    This study presents a simple, robust and environmentally friendly solid phase preconcentration procedure for multielement determination by inductively coupled plasma optical emission spectrometry (ICP-OES) using diphenylcarbazone (DPC) impregnated TiO2 nanopowder (n-TiO2). DPC was successfully impregnated onto n-TiO2 in colloidal solution. A number of elements, including Co(II), Cr(III), Cu(II), Fe(III), Mn(II) and Zn(II) were quantitatively preconcentrated from aqueous solutions between pH 8 and 8.5 at a flow rate of 2 mL min−1, and then eluted with 2 mL of 5% (v/v) HNO3. A mini-column packed with 0.12 g DPC impregnated n-TiO2 retained all elements quantitatively from up to 250 mL multielement solution (2.5 μg per analyte) affording an enrichment factor of 125. The limits of detection (LOD) for preconcentration of 50 mL blank solutions (n = 12) were 0.28, 0.15, 0.25, 0.22, 0.12, and 0.10 μg L−1 for Co, Cr, Cu, Fe, Mn, and Zn, respectively. The relative standard deviation (RSD) for five replicate determinations was 0.8, 3.4, 2.6, 2.2, 1.2 and 3.3% for Co, Cr, Cu, Fe, Mn and Zn, respectively, at 5 μg L−1 level. The method was validated with analysis of Freshwater (SRM 1643e) and Lobster hepatopancreas (TORT-2) certified reference materials, and then applied to the determination of the elements from tap water and lake water samples by ICP-OES. PMID:26236403

  8. Validation of a standardized extraction method for formalin-fixed paraffin-embedded tissue samples.

    PubMed

    Lagheden, Camilla; Eklund, Carina; Kleppe, Sara Nordqvist; Unger, Elizabeth R; Dillner, Joakim; Sundström, Karin

    2016-07-01

    Formalin-fixed paraffin-embedded (FFPE) samples can be DNA-extracted and used for human papillomavirus (HPV) genotyping. The xylene-based gold standard for extracting FFPE samples is laborious, suboptimal and involves health hazards for the personnel involved. To compare extraction with the standard xylene method to a xylene-free method used in an HPV LabNet Global Reference Laboratory at the Centers for Disease Control (CDC); based on a commercial method with an extra heating step. Fifty FFPE samples were randomly selected from a national audit of all cervical cancer cases diagnosed in Sweden during 10 years. For each case-block, a blank-block was sectioned, as a control for contamination. For xylene extraction, the standard WHO Laboratory Manual protocol was used. For the CDC method, the manufacturers' protocol was followed except for an extra heating step, 120°C for 20min. Samples were extracted and tested in parallel with β-globin real-time PCR, HPV16 real-time PCR and HPV typing using modified general primers (MGP)-PCR and Luminex assays. For a valid result the blank-block had to be betaglobin-negative in all tests and the case-block positive for beta-globin. Overall, detection was improved with the heating method and the amount of HPV-positive samples increased from 70% to 86% (p=0.039). For all samples where HPV type concordance could be evaluated, there was 100% type concordance. A xylene-free and robust extraction method for HPV-DNA typing in FFPE material is currently in great demand. Our proposed standardized protocol appears to be generally useful. Copyright © 2016. Published by Elsevier B.V.

  9. Automatic classification of blank substrate defects

    NASA Astrophysics Data System (ADS)

    Boettiger, Tom; Buck, Peter; Paninjath, Sankaranarayanan; Pereira, Mark; Ronald, Rob; Rost, Dan; Samir, Bhamidipati

    2014-10-01

    Mask preparation stages are crucial in mask manufacturing, since this mask is to later act as a template for considerable number of dies on wafer. Defects on the initial blank substrate, and subsequent cleaned and coated substrates, can have a profound impact on the usability of the finished mask. This emphasizes the need for early and accurate identification of blank substrate defects and the risk they pose to the patterned reticle. While Automatic Defect Classification (ADC) is a well-developed technology for inspection and analysis of defects on patterned wafers and masks in the semiconductors industry, ADC for mask blanks is still in the early stages of adoption and development. Calibre ADC is a powerful analysis tool for fast, accurate, consistent and automatic classification of defects on mask blanks. Accurate, automated classification of mask blanks leads to better usability of blanks by enabling defect avoidance technologies during mask writing. Detailed information on blank defects can help to select appropriate job-decks to be written on the mask by defect avoidance tools [1][4][5]. Smart algorithms separate critical defects from the potentially large number of non-critical defects or false defects detected at various stages during mask blank preparation. Mechanisms used by Calibre ADC to identify and characterize defects include defect location and size, signal polarity (dark, bright) in both transmitted and reflected review images, distinguishing defect signals from background noise in defect images. The Calibre ADC engine then uses a decision tree to translate this information into a defect classification code. Using this automated process improves classification accuracy, repeatability and speed, while avoiding the subjectivity of human judgment compared to the alternative of manual defect classification by trained personnel [2]. This paper focuses on the results from the evaluation of Automatic Defect Classification (ADC) product at MP Mask Technology Center (MPMask). The Calibre ADC tool was qualified on production mask blanks against the manual classification. The classification accuracy of ADC is greater than 95% for critical defects with an overall accuracy of 90%. The sensitivity to weak defect signals and locating the defect in the images is a challenge we are resolving. The performance of the tool has been demonstrated on multiple mask types and is ready for deployment in full volume mask manufacturing production flow. Implementation of Calibre ADC is estimated to reduce the misclassification of critical defects by 60-80%.

  10. Groundwater-quality data in the Klamath Mountains study unit, 2010: results from the California GAMA Program

    USGS Publications Warehouse

    Mathany, Timothy M.; Belitz, Kenneth

    2014-01-01

    Groundwater quality in the 8,806-square-mile Klamath Mountains (KLAM) study unit was investigated by the U.S. Geological Survey (USGS) from October to December 2010, as part of the California State Water Resources Control Board (SWRCB) Groundwater Ambient Monitoring and Assessment (GAMA) Program’s Priority Basin Project (PBP). The GAMA-PBP was developed in response to the California Groundwater Quality Monitoring Act of 2001 and is being conducted in collaboration with the SWRCB and Lawrence Livermore National Laboratory (LLNL). The KLAM study unit was the thirty-third study unit to be sampled as part of the GAMA-PBP. The GAMA Klamath Mountains study was designed to provide a spatially unbiased assessment of untreated-groundwater quality in the primary aquifer system and to facilitate statistically consistent comparisons of untreated-groundwater quality throughout California. The primary aquifer system is defined by the perforation intervals of wells listed in the California Department of Public Health (CDPH) database for the KLAM study unit. Groundwater quality in the primary aquifer system may differ from the quality in the shallower or deeper water-bearing zones; shallower groundwater may be more vulnerable to surficial contamination. In the KLAM study unit, groundwater samples were collected from sites in Del Norte, Siskiyou, Humboldt, Trinity, Tehama, and Shasta Counties, California. Of the 39 sites sampled, 38 were selected by using a spatially distributed, randomized grid-based method to provide statistical representation of the primary aquifer system in the study unit (grid sites), and the remaining site was non-randomized (understanding site). The groundwater samples were analyzed for basic field parameters, organic constituents (volatile organic compounds [VOCs] and pesticides and pesticide degradates), inorganic constituents (trace elements, nutrients, major and minor ions, total dissolved solids [TDS]), radon-222, gross alpha and gross beta radioactivity, and microbial indicators (total coliform and Escherichia coli [E. coli]). Isotopic tracers (stable isotopes of hydrogen and oxygen in water, isotopic ratios of dissolved strontium in water, and stable isotopes of carbon in dissolved inorganic carbon), dissolved noble gases, and age-dating tracers (tritium and carbon-14) were measured to help identify sources and ages of sampled groundwater. Quality-control samples (field blanks, replicate sample pairs, and matrix spikes) were collected at 13 percent of the sites in the KLAM study unit, and the results were used to evaluate the quality of the data from the groundwater samples. Field blank samples rarely contained detectable concentrations of any constituent, indicating that contamination from sample collection or analysis was not a significant source of bias in the data for the groundwater samples. More than 99 percent of the replicate pair samples were within acceptable limits of variability. Matrix-spike sample recoveries were within the acceptable range (70 to 130 percent) for approximately 91 percent of the compounds. This study did not evaluate the quality of water delivered to consumers. After withdrawal, groundwater typically is treated, disinfected, and (or) blended with other waters to maintain water quality. Regulatory benchmarks apply to water that is delivered to the consumer, not to untreated groundwater. However, to provide some context for the results, concentrations of constituents measured in the untreated groundwater were compared with regulatory and non-regulatory health-based benchmarks established by the U.S. Environmental Protection Agency (USEPA) and CDPH, and to non-health-based benchmarks established for aesthetic concerns by the CDPH. Comparisons between data collected for this study and benchmarks for drinking water are for illustrative purposes only and are not indicative of compliance or non-compliance with those benchmarks. All concentrations of organic constituents from grid sites sampled in the KLAM study unit were less than health-based benchmarks. In total, VOCs were detected in 16 of the 38 grid sites sampled (approximately 42 percent), pesticides and pesticide degradates were detected in 8 grid sites (about 21 percent), and microbial indicators were detected in 14 grid sites (approximately 37 percent). Inorganic constituents (trace elements, major and minor ions, nutrients, and uranium and other radioactive constituents) and microbial indicators were sampled for at 38 grid sites, and all concentrations were less than health-based benchmarks, with the exception of one detection of boron greater than the CDPH notification level of 1,000 micrograms per liter (μg/L). Generally, concentrations of inorganic constituents with non-health-based benchmarks (iron, manganese, chloride, and TDS) were less than the CDPH secondary maximum contaminant level (SMCL-CA). Exceptions include three detections of iron greater than the SMCL-CA of 300 μg/L, four detections of manganese greater than the SMCL-CA of 50 μg/L, one detection of chloride greater than the recommended SMCL-CA of 250 μg/L, and one detection of TDS greater than the recommended SMCL-CA of 500 μg/L.

  11. Mass Spectral Investigations on Toxins. 2. Simultaneous Detection and Quantification of Ultra-Trace Levels of Simple Trichothecenes in Environmental and Fermentation Samples by Gas Chromatographic/Negative Ion Chemical Ionization-Mass Spectrometric Techniques

    DTIC Science & Technology

    1987-01-01

    due to interferences in the pollen. However, the identity of the interferents is presently unknown. A dried papaya leaf was treated with 10 ml of warm...Known amounts of DON, DAS, and T-2 were spiked on a blank (trichothecene-free) papaya leaf and left exposed in a bottle for 1 year. At the end of the year...Simple Trichothecenes from Leaf Sample after Prolonged Exposure ............... 35 12 Sample Analysis .............................. .... 37 6 MASS

  12. The Fall 1973 New Student Week Leaders at Southern Illinois University at Carbondale.

    ERIC Educational Resources Information Center

    Paciello, Antonio Joseph

    This study describes a sample of college students who participated as New Student Week Leaders (NSWL). Vocational interests, as measured by the Strong Vocational Interest Blank for Men (SVIB-M), academic pursuits, campus involvement, and other factors were considered in an attempt to define a NSWL. Eighty-six items were chosen from the SVIB-M to…

  13. Production of the 4.1-m Zerodur mirror blank for the VISTA Telescope

    NASA Astrophysics Data System (ADS)

    Doehring, Thorsten; Jedamzik, Ralf; Wittmer, Volker; Thomas, Armin

    2004-09-01

    VISTA (Visible and Infrared Survey Telescope for Astronomy) is designed to be the world's largest wide field telescope. After finishing of the construction the telescope will be part of ESO and located in Chile close to the VLT observatory at Cerro Paranal. In November 2001 SCHOTT was selected by the VISTA project office at the Royal Observatory of Edinburgh to deliver the 4.1 m diameter primary mirror blank. The manufacturing of the mirror blank made from the zero expansion material Zerodur was challenging especially due to the f/1 design. Several tons of the glass ceramic material were removed during the grinding operation. A meniscus blank with a diameter of 4100 mm and a thickness of 171.5 mm was generated, having a large central hole of 1200 mm and an aspherical shape of the concave surface. Also the handling and turning operations needed special effort and were performed by a skilled team. This paper presents details and pictures of the corresponding production and inspection sequence at SCHOTT. The geometrical parameters were measured during manufacturing by help of a laser tracker system and the achieved parameters were compared with the initial technical specification. The final quality inspection verified the excellent quality of the mirror blank. The close co-operation between the astronomers and industry resulted in a project management without problems. In April 2003 the VISTA blank was delivered successfully within a ceremony dedicated to the anniversary of "100 years of astronomical mirror blanks from SCHOTT."

  14. High-speed blanking of copper alloy sheets: Material modeling and simulation

    NASA Astrophysics Data System (ADS)

    Husson, Ch.; Ahzi, S.; Daridon, L.

    2006-08-01

    To optimize the blanking process of thin copper sheets ( ≈ 1. mm thickness), it is necessary to study the influence of the process parameters such as the punch-die clearance and the wear of the punch and the die. For high stroke rates, the strain rate developed in the work-piece can be very high. Therefore, the material modeling must include the dynamic effects.For the modeling part, we propose an elastic-viscoplastic material model combined with a non-linear isotropic damage evolution law based on the theory of the continuum damage mechanics. Our proposed modeling is valid for a wide range of strain rates and temperatures. Finite Element simulations, using the commercial code ABAQUS/Explicit, of the blanking process are then conducted and the results are compared to the experimental investigations. The predicted cut edge of the blanked part and the punch-force displacement curves are discussed as function of the process parameters. The evolution of the shape errors (roll-over depth, fracture depth, shearing depth, and burr formation) as function of the punch-die clearance, the punch and the die wear, and the contact punch/die/blank-holder are presented. A discussion on the different stages of the blanking process as function of the processing parameters is given. The predicted results of the blanking dependence on strain-rate and temperature using our modeling are presented (for the plasticity and damage). The comparison our model results with the experimental ones shows a good agreement.

  15. Alkaline digestion and solid phase extraction method for perfluorinated compounds in mussels and oysters from South China and Japan.

    PubMed

    So, M K; Taniyasu, S; Lam, P K S; Zheng, G J; Giesy, J P; Yamashita, N

    2006-02-01

    Perfluorinated compounds (PFCs), such as perfluorooctane sulfonate (PFOS), have been identified in the coastal waters of China and Japan. An alkaline digestion method, coupled with solid-phase extraction (SPE), and high-performance liquid chromatography interfaced with high-resolution electrospray tandem mass spectrometry was developed to determine PFCs in mussel and oyster samples from coastal waters of South China and Japan. These techniques produced adequate recoveries and reporting limits with small quantities of PFCs. Concentrations of individual PFCs in mussels and oysters from South China and Japan ranged from 113.6 to 586.0 pg/g, wet weight (ww) for PFOS, 63.1 to 511.6 pg/g, ww for perfluorohexane sulfonate, 9.3 to 30.1 pg/g, ww for perfluorobutane sulfonate and 37.8 to 2957.0 pg/g, ww for perfluorooctane sulfonamide. The quantification of perfluorinated carboxylates was compromised by interferences from carboxylates in the procedural blanks. Perfluoroundecanoate and perfluorononanoate had relatively great blank interferences, which resulted in relatively poor limits of quantification for these compounds. Some PFCs were only identified in a limited number of samples: perfluorododecanoate in samples from Tokyo Bay, Japan (195.9 pg/g, ww); and perfluorodecanoate in Fuzhou, China (131.7 pg/g, ww) and Tokyo Bay (118.6 pg/g, ww). The greatest concentrations of perfluorooctanoate, perfluoroheptanoate, and perfluorohexanoate were observed in samples from Tokyo Bay and Bei Hai, South China.

  16. Sample preparation composite and replicate strategy case studies for assay of solid oral drug products.

    PubMed

    Nickerson, Beverly; Harrington, Brent; Li, Fasheng; Guo, Michele Xuemei

    2017-11-30

    Drug product assay is one of several tests required for new drug products to ensure the quality of the product at release and throughout the life cycle of the product. Drug product assay testing is typically performed by preparing a composite sample of multiple dosage units to obtain an assay value representative of the batch. In some cases replicate composite samples may be prepared and the reportable assay value is the average value of all the replicates. In previously published work by Harrington et al. (2014) [5], a sample preparation composite and replicate strategy for assay was developed to provide a systematic approach which accounts for variability due to the analytical method and dosage form with a standard error of the potency assay criteria based on compendia and regulatory requirements. In this work, this sample preparation composite and replicate strategy for assay is applied to several case studies to demonstrate the utility of this approach and its application at various stages of pharmaceutical drug product development. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. The Muslim Brotherhood and Modern Education: How Will the Muslim Brotherhood Address Egypt’s Failing Education System?

    DTIC Science & Technology

    2012-09-01

    Thesis Advisor: Robert Springborg Second Reader: Mohammed M. Hafez THIS PAGE INTENTIONALLY LEFT BLANK i REPORT DOCUMENTATION PAGE Form...of secular subjects. vi THIS PAGE INTENTIONALLY LEFT BLANK vii TABLE OF CONTENTS I . INTRODUCTION...understanding, this thesis would not have been possible. xii THIS PAGE INTENTIONALLY LEFT BLANK 1 I . INTRODUCTION A. MAJOR RESEARCH QUESTION The

  18. Exploring Valued-Added Options - Edge-Glued Panels and Blanks Offer Value-Added Opportunities

    Treesearch

    Bob Smith; Philip A. Araman

    1997-01-01

    As sawmills search for new opportunities to add value to rough sawn lumber, many consider producing dimension parts as one solution. Assembling dimension parts into edge-glued panels or standard blanks can add even further value. Blanks are defined as pieces of solid wood (which may be edge-glued) that are manufactured to a predetermined size. This article discusses...

  19. A gunner model for an AAA tracking task with interrupted observations

    NASA Technical Reports Server (NTRS)

    Yu, C. F.; Wei, K. C.; Vikmanis, M.

    1982-01-01

    The problem of modeling a trained human operator's tracking performance in an anti-aircraft system under various display blanking conditions is discussed. The input to the gunner is the observable tracking error subjected to repeated interruptions (blanking). A simple and effective gunner model was developed. The effect of blanking on the gunner's tracking performance is approached via modeling the observer and controller gains.

  20. Penetrating ocular trauma associated with blank cartridge

    PubMed Central

    2014-01-01

    Background Blank cartridge guns are generally regarded as being harmless and relative safe. However recent published articles demonstrated that the gas pressure from the exploding propellant of blank cartridge is powerful enough to penetrate the thoracic wall, abdominal muscle, small intestine and the skull. And there has been a limited number of case reports of ocular trauma associated with blank cartridge injury. In addition, no report on case with split extraocular muscle injury with traumatic cataract and penetrating corneoscleral wound associated with blank cartridge has been previously documented. This report describes the case of patient who sustained penetrating ocular injury with extraocular muscle injury by a close-distance blank cartridge that required surgical intervention. Case presentation A 20-year-old man sustained a penetrating globe injury in the right eye while cleaning a blank cartridge pistol. His uncorrected visual acuity at presentation was hand motion and he had a flame burn of his right upper and lower lid with multiple missile wounds. On slit-lamp examination, there was a 12-mm laceration of conjunctiva along the 9 o'clock position with two pinhole-like penetrating injuries of cornea and sclera. There was also a 3-mm corneal laceration between 9 o'clock and 12 o'clock and the exposed lateral rectus muscle was split. Severe Descemet's membrane folding with stromal edema was observed, and numerous yellow, powder-like foreign bodies were impacted in the cornea. Layered anterior chamber bleeding with traumatic cataract was also noted. Transverse view of ultrasonography showed hyperechoic foreign bodies with mild reduplication echoes and shadowing. However, a computed tomographic scan using thin section did not reveal a radiopaque foreign body within the right globe. Conclusion To our best knowledge, this is the first case report of split extraocular muscle injury with traumatic cataract and penetrating ocular injury caused by blank cartridge injury. Intraocular foreign bodies undetectable by CT were identified by B-scan ultrasonography in our patient. This case highlights the importance of additional ultrasonography when evaluating severe ocular trauma. And ophthalmologists should consider the possibility of penetrating injury caused by blank ammunition. PMID:24589340

  1. Quality-Assurance Data for Routine Water Analyses by the U.S. Geological Survey Laboratory in Troy, New York--July 1999 through June 2001

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2006-01-01

    The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's LabMaster data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality-control samples analyzed from July 1999 through June 2001. Results for the quality-control samples for 18 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, total aluminum, calcium, chloride and nitrate (ion chromatography and colormetric method) and sulfate. The total aluminum and dissolved organic carbon procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits. The calcium and specific conductance procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The magnesium procedure was biased for the high-concentration and low concentration samples, but was within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 14 of 15 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 17 of the 18 analytes. At least 90 percent of the samples met data-quality objectives for all analytes except ammonium (81 percent of samples met objectives), chloride (75 percent of samples met objectives), and sodium (86 percent of samples met objectives). Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality over the time period, with most ratings for each sample in the good to excellent range. The P-sample (low-ionic-strength constituents) analysis had one satisfactory rating for the specific conductance procedure in one study. The T-sample (trace constituents) analysis had one satisfactory rating for the aluminum procedure in one study and one unsatisfactory rating for the sodium procedure in another. The remainder of the samples had good or excellent ratings for each study. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 89 percent of the samples met data-quality objectives for 10 of the 14 analytes; the exceptions were ammonium, total aluminum, dissolved organic carbon, and sodium. Results indicate a positive bias for the ammonium procedure in all studies. Data-quality objectives were not met in 50 percent of samples analyzed for total aluminum, 38 percent of samples analyzed for dissolved organic carbon, and 27 percent of samples analyzed for sodium. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 91 percent of the samples analyzed for calcium, chloride, fluoride, magnesium, pH, potassium, and sulfate. Data-quality objectives were met by 75 percent of the samples analyzed for sodium and 58 percent of the samples analyzed for specific conductance.

  2. Formation mechanism of the photomask blanks material related haze

    NASA Astrophysics Data System (ADS)

    Kim, Jung-Jin; Choi, Junyoul; Koh, Soowan; Kim, Minho; Lee, Jiyoung; Lee, Han-Shin; Kim, Byung Gook; Jeon, Chan-uk

    2016-05-01

    We have observed a new type haze of which formation deviates from the generally accepted models with respect to the size, shape, and removability by chemicals. It has very small size of 50~100nm and are crowded around the cell boundary, while the typical haze doesn't prefer a special region on mask in the majority of cases. It is hard to remove by general cleaning, while the typical haze is easily removed by general cleaning process and even de-ionized water. It is confirmed that the source of the haze is blank material related ions which are formed by chemical etching of blanks during mask cleaning process or the photomask blanks itself.

  3. Cloud property datasets retrieved from AVHRR, MODIS, AATSR and MERIS in the framework of the Cloud_cci project

    NASA Astrophysics Data System (ADS)

    Stengel, Martin; Stapelberg, Stefan; Sus, Oliver; Schlundt, Cornelia; Poulsen, Caroline; Thomas, Gareth; Christensen, Matthew; Carbajal Henken, Cintia; Preusker, Rene; Fischer, Jürgen; Devasthale, Abhay; Willén, Ulrika; Karlsson, Karl-Göran; McGarragh, Gregory R.; Proud, Simon; Povey, Adam C.; Grainger, Roy G.; Fokke Meirink, Jan; Feofilov, Artem; Bennartz, Ralf; Bojanowski, Jedrzej S.; Hollmann, Rainer

    2017-11-01

    New cloud property datasets based on measurements from the passive imaging satellite sensors AVHRR, MODIS, ATSR2, AATSR and MERIS are presented. Two retrieval systems were developed that include components for cloud detection and cloud typing followed by cloud property retrievals based on the optimal estimation (OE) technique. The OE-based retrievals are applied to simultaneously retrieve cloud-top pressure, cloud particle effective radius and cloud optical thickness using measurements at visible, near-infrared and thermal infrared wavelengths, which ensures spectral consistency. The retrieved cloud properties are further processed to derive cloud-top height, cloud-top temperature, cloud liquid water path, cloud ice water path and spectral cloud albedo. The Cloud_cci products are pixel-based retrievals, daily composites of those on a global equal-angle latitude-longitude grid, and monthly cloud properties such as averages, standard deviations and histograms, also on a global grid. All products include rigorous propagation of the retrieval and sampling uncertainties. Grouping the orbital properties of the sensor families, six datasets have been defined, which are named AVHRR-AM, AVHRR-PM, MODIS-Terra, MODIS-Aqua, ATSR2-AATSR and MERIS+AATSR, each comprising a specific subset of all available sensors. The individual characteristics of the datasets are presented together with a summary of the retrieval systems and measurement records on which the dataset generation were based. Example validation results are given, based on comparisons to well-established reference observations, which demonstrate the good quality of the data. In particular the ensured spectral consistency and the rigorous uncertainty propagation through all processing levels can be considered as new features of the Cloud_cci datasets compared to existing datasets. In addition, the consistency among the individual datasets allows for a potential combination of them as well as facilitates studies on the impact of temporal sampling and spatial resolution on cloud climatologies.

    For each dataset a digital object identifier has been issued:

    Cloud_cci AVHRR-AM: https://doi.org/10.5676/DWD/ESA_Cloud_cci/AVHRR-AM/V002

    Cloud_cci AVHRR-PM: https://doi.org/10.5676/DWD/ESA_Cloud_cci/AVHRR-PM/V002

    Cloud_cci MODIS-Terra: https://doi.org/10.5676/DWD/ESA_Cloud_cci/MODIS-Terra/V002

    Cloud_cci MODIS-Aqua: https://doi.org/10.5676/DWD/ESA_Cloud_cci/MODIS-Aqua/V002

    Cloud_cci ATSR2-AATSR: https://doi.org/10.5676/DWD/ESA_Cloud_cci/ATSR2-AATSR/V002

    Cloud_cci MERIS+AATSR: https://doi.org/10.5676/DWD/ESA_Cloud_cci/MERIS+AATSR/V002

  4. Estimating surface hardening profile of blank for obtaining high drawing ratio in deep drawing process using FE analysis

    NASA Astrophysics Data System (ADS)

    Tan, C. J.; Aslian, A.; Honarvar, B.; Puborlaksono, J.; Yau, Y. H.; Chong, W. T.

    2015-12-01

    We constructed an FE axisymmetric model to simulate the effect of partially hardened blanks on increasing the limiting drawing ratio (LDR) of cylindrical cups. We partitioned an arc-shaped hard layer into the cross section of a DP590 blank. We assumed the mechanical property of the layer is equivalent to either DP980 or DP780. We verified the accuracy of the model by comparing the calculated LDR for DP590 with the one reported in the literature. The LDR for the partially hardened blank increased from 2.11 to 2.50 with a 1 mm depth of DP980 ring-shaped hard layer on the top surface of the blank. The position of the layer changed with drawing ratios. We proposed equations for estimating the inner and outer diameters of the layer, and tested its accuracy in the simulation. Although the outer diameters fitted in well with the estimated line, the inner diameters are slightly less than the estimated ones.

  5. Lightweight ZERODUR mirror blanks: recent advances supporting faster, cheaper, and better spaceborne optical telescope assemblies

    NASA Astrophysics Data System (ADS)

    Hull, Tony; Westerhoff, Thomas

    2014-10-01

    While there is no single material solution ideal for all missions, recent advances by SCHOTT in fabricating lightweight mirror blanks makes ZERODUR® a highly viable solution for many spaceborne telescopes. ZERODUR® is a well-characterized very low-expansion material. Monolithic mirrors are made without bonding or fusing out of highly homogeneous and isotropic blanks currently available in sizes up to 4m plus. We will summarize results recently given in a series of papers on the characteristics of these lightweight mirror blanks in sizes from 0.3m up, and describe the method of blank fabrication, with its compatibility to contemporary optical fabrication techniques that control of all optical spatial frequencies. ZERODUR® has a 35 year heritage in space on numerous missions, including the secondary mirror of Hubble, and all the Chandra mirrors. With the lightweighting we will discuss, ZERODUR® is now a high performing, affordable and rapidly produced mirror substrate suitable for lightweight imaging telescopes.

  6. A Bayesian Perspective on the Reproducibility Project: Psychology

    PubMed Central

    Etz, Alexander; Vandekerckhove, Joachim

    2016-01-01

    We revisit the results of the recent Reproducibility Project: Psychology by the Open Science Collaboration. We compute Bayes factors—a quantity that can be used to express comparative evidence for an hypothesis but also for the null hypothesis—for a large subset (N = 72) of the original papers and their corresponding replication attempts. In our computation, we take into account the likely scenario that publication bias had distorted the originally published results. Overall, 75% of studies gave qualitatively similar results in terms of the amount of evidence provided. However, the evidence was often weak (i.e., Bayes factor < 10). The majority of the studies (64%) did not provide strong evidence for either the null or the alternative hypothesis in either the original or the replication, and no replication attempts provided strong evidence in favor of the null. In all cases where the original paper provided strong evidence but the replication did not (15%), the sample size in the replication was smaller than the original. Where the replication provided strong evidence but the original did not (10%), the replication sample size was larger. We conclude that the apparent failure of the Reproducibility Project to replicate many target effects can be adequately explained by overestimation of effect sizes (or overestimation of evidence against the null hypothesis) due to small sample sizes and publication bias in the psychological literature. We further conclude that traditional sample sizes are insufficient and that a more widespread adoption of Bayesian methods is desirable. PMID:26919473

  7. A Bayesian Perspective on the Reproducibility Project: Psychology.

    PubMed

    Etz, Alexander; Vandekerckhove, Joachim

    2016-01-01

    We revisit the results of the recent Reproducibility Project: Psychology by the Open Science Collaboration. We compute Bayes factors-a quantity that can be used to express comparative evidence for an hypothesis but also for the null hypothesis-for a large subset (N = 72) of the original papers and their corresponding replication attempts. In our computation, we take into account the likely scenario that publication bias had distorted the originally published results. Overall, 75% of studies gave qualitatively similar results in terms of the amount of evidence provided. However, the evidence was often weak (i.e., Bayes factor < 10). The majority of the studies (64%) did not provide strong evidence for either the null or the alternative hypothesis in either the original or the replication, and no replication attempts provided strong evidence in favor of the null. In all cases where the original paper provided strong evidence but the replication did not (15%), the sample size in the replication was smaller than the original. Where the replication provided strong evidence but the original did not (10%), the replication sample size was larger. We conclude that the apparent failure of the Reproducibility Project to replicate many target effects can be adequately explained by overestimation of effect sizes (or overestimation of evidence against the null hypothesis) due to small sample sizes and publication bias in the psychological literature. We further conclude that traditional sample sizes are insufficient and that a more widespread adoption of Bayesian methods is desirable.

  8. Laboratory Noble Gas Migration Experiments through Rock

    NASA Astrophysics Data System (ADS)

    Broome, S.; Cashion, A.; Feldman, J.; Sussman, A. J.; Swanson, E.; Wilson, J.

    2016-12-01

    The Underground Nuclear Explosion Signatures Experiment (UNESE) was created to address science and research and development aspects associated with nuclear explosion verification and nuclear nonproliferation with a focus on non-prompt signals. A critical component of the UNESE program is a realistic understanding of the post-detonation processes and changes in the environment that produce observable physical and radio-chemical signatures. As such, an understanding of noble gas migration properties through various lithologies is essential. Here we present an empirical methodology to measure tortuosity on well-characterized rhyolitic tuffs and lavas. Tortuosity is then compared with microfracture networks characterized by microscopy. To quantify tortuosity, a pressurized (1500 mbar) fixed volume of argon is expanded into a sample under high vacuum (0.200 mbar). A quadrupole mass spectrometer (QMS) is used to measure argon downstream of the sample in real time, allowing the time-series gas arrival curve to be characterized for each sample. To evaluate the method, blank samples have been machined to correspond with tortuosities of 1, 2, and 4 in conjunction with a restricted-flow valve to mimic rock sample permeability. Data from the blanks are analyzed with this system to correct for system effects on gas arrival. High vacuum is maintained in the QMS system during sampling by precise metering of the gas through a leak valve with active feedback control which allows arrival time and concentration of argon to be established in real time. Along with a comprehensive characterization of the rock and fracture properties, the parameters derived from these experiments will provide invaluable insight into the three-dimensional structure of damage zones, the production of temporally variable signatures and the methods to best detect underground nuclear explosion signatures. SAND2016-7309 A

  9. Seal for fluid forming tools

    DOEpatents

    Golovashchenko, Sergey Fedorovich [Beverly Hills, MI; Bonnen, John Joseph Francis [Milford, MI

    2012-03-20

    An electro-hydraulic forming tool for forming a sheet metal blank in a one-sided die has first and second rigid rings that engage opposite sides of a sheet metal blank. The rigid rings are contained within slots on a die portion and a hydraulic force applicator portion of the forming tool. The seals are either resiliently biased by an elastomeric member or inherently resiliently biased into contact with the blank.

  10. δ13C Analysis of Dissolved Organic Carbon in Eastern Canadian Coastal Waters

    NASA Astrophysics Data System (ADS)

    Gelinas, Y.; Barber, A.

    2016-12-01

    The application of carbon stable isotope analysis on dissolved organic carbon (δ13C-DOC) from natural seawater samples has been limited owing to the difficulty of such analysis, with order of magnitude differences between interfering ions and analyte concentrations. High temperature catalytic oxidation allows for the separation of interferences from the organic carbon by precipitation on quartz chips upstream from the oxidation catalyst. Unlike wet chemical oxidation, where salts inhibit the oxidation of organic matter to CO2 via side reactions between the salt anions and the persulfate oxidizing agent, high temperature combustion ensures complete organic matter oxidation in a stream of O2. Using a programmable chemical trap to switch carrier gasses from O2 to He, the OI 1030C combustion unit can be coupled to and IRMS, allowing for the analysis of low DOC content saline waters with relatively high throughput. The analytical limitations and large water volumes traditionally required for these types of analyses have prevented any large-scale δ13C-DOC studies. Here we present DOC concentrations and δ13C-DOC signatures for surface and bottom waters obtained along Canada's East Coast. Included in the study are samples from the Esquiman channel (between Newfoundland and Labrador), Lake Melville, the Saglek and Nachvak Fjords, the Hudson Strait and finally covering the salinity gradient across the Gulf of the St. Lawrence, the St. Lawrence Estuary and the Saguenay Fjord. Measured δ13C-DOC signatures ranged from predominantly marine values of -21.3 ± 0.6 ‰ (vs. VPDB) off the coast of Newfoundland to predominantly terrestrial signatures of -25.8 ± 0.1‰ in Lake Melville. Overall, proper blank subtraction using the isotope mass balance equation and four replicate injections are crucial for the collection of meaningful high quality δ13C-DOC signatures on natural abundance, seawater samples.

  11. Aqueous Geochemical Data From the Analysis of Stream-Water Samples Collected in June and July 2005--Taylor Mountains 1:250,000 Scale Quadrangle, Alaska

    USGS Publications Warehouse

    Wang, Bronwen; Mueller, Seth; Stetson, Sarah; Bailey, Elizabeth; Lee, Greg

    2006-01-01

    We report on the chemical analysis of water samples collected from the Taylor Mountains 1:250,000-scale quadrangle. Parameters for which data are reported include pH, conductivity, water temperature, major cation and anion concentrations, trace-element concentrations, and dissolved organic-carbon concentrations. Samples were collected as part of a multiyear U.S. Geological Survey project 'Geologic and Mineral Deposit Data for Alaskan Economic Development.' Data presented here are from samples collected in June and July of 2005. The data are being released at this time with minimal interpretation. This is the second release of aqueous geochemical data from this project; 2004 aqueous geochemical data were published previously (Wang and others, 2006). The data in this report augment but do not duplicate or supersede the previous data release. Site selection was based on a regional sampling strategy that focused on first- and second-order drainages. Water sample site selection was based on landscape parameters that included physiography, wetland extent, lithological changes, and a cursory field review of mineralogy from pan concentrates. Stream water in the Taylor Mountians quadrangle is dominated by bicarbonate (HCO3-), though in a few samples more than 50 percent of the anionic charge can be attributed to sulfate (SO42-). The major-cation chemistry ranges from Ca2+/Mg2+ dominated to a mix of Ca2+/Mg2+/Na++K+. In general, good agreement was found between the major cations and anions in the duplicate samples. Many trace elements in these samples were at or near the analytical method detection limit, but good agreement was found between duplicate samples for elements with detectable concentrations. With the exception of a total mercury concentration of 0.33 ng/L detected in a field blank, field blank major-ion and trace-elements concentrations were below detection.

  12. Large optical glass blanks for the ELT generation

    NASA Astrophysics Data System (ADS)

    Jedamzik, Ralf; Petzold, Uwe; Dietrich, Volker; Wittmer, Volker; Rexius, Olga

    2016-07-01

    The upcoming extremely large telescope projects like the E-ELT, TMT or GMT telescopes require not only large amount of mirror blank substrates but have also sophisticated instrument setups. Common instrument components are atmospheric dispersion correctors that compensate for the varying atmospheric path length depending on the telescope inclination angle. These elements consist usually of optical glass blanks that have to be large due to the increased size of the focal beam of the extremely large telescopes. SCHOTT has a long experience in producing and delivering large optical glass blanks for astronomical applications up to 1 m and in homogeneity grades up to H3 quality in the past. The most common optical glass available in large formats is SCHOTT N-BK7. But other glass types like F2 or LLF1 can also be produced in formats up to 1 m. The extremely large telescope projects partly demand atmospheric dispersion components even in sizes beyond 1m up to a range of 1.5 m diameter. The production of such large homogeneous optical glass banks requires tight control of all process steps. To cover this demand in the future SCHOTT initiated a research project to improve the large optical blank production process steps from melting to annealing and measurement. Large optical glass blanks are measured in several sub-apertures that cover the total clear aperture of the application. With SCHOTT's new stitching software it is now possible to combine individual sub-aperture measurements to a total homogeneity map of the blank. In this presentation first results will be demonstrated.

  13. Edge Length and Surface Area of a Blank: Experimental Assessment of Measures, Size Predictions and Utility

    PubMed Central

    Dogandžić, Tamara; Braun, David R.; McPherron, Shannon P.

    2015-01-01

    Blank size and form represent one of the main sources of variation in lithic assemblages. They reflect economic properties of blanks and factors such as efficiency and use life. These properties require reliable measures of size, namely edge length and surface area. These measures, however, are not easily captured with calipers. Most attempts to quantify these features employ estimates; however, the efficacy of these estimations for measuring critical features such as blank surface area and edge length has never been properly evaluated. In addition, these parameters are even more difficult to acquire for retouched implements as their original size and hence indication of their previous utility have been lost. It has been suggested, in controlled experimental conditions, that two platform variables, platform thickness and exterior platform angle, are crucial in determining blank size and shape meaning that knappers can control the interaction between size and efficiency by selecting specific core angles and controlling where fracture is initiated. The robustness of these models has rarely been tested and confirmed in context other than controlled experiments. In this paper, we evaluate which currently employed caliper measurement methods result in the highest accuracy of size estimations of blanks, and we evaluate how platform variables can be used to indirectly infer aspects of size on retouched artifacts. Furthermore, we investigate measures of different platform management strategies that control the shape and size of artifacts. To investigate these questions, we created an experimental lithic assemblage, we digitized images to calculate 2D surface area and edge length, which are used as a point of comparison for the caliper measurements and additional analyses. The analysis of aspects of size determinations and the utility of blanks contributes to our understanding of the technological strategies of prehistoric knappers and what economic decisions they made during process of blank production. PMID:26332773

  14. Meta-analysis of Parkinson's disease: identification of a novel locus, RIT2.

    PubMed

    Pankratz, Nathan; Beecham, Gary W; DeStefano, Anita L; Dawson, Ted M; Doheny, Kimberly F; Factor, Stewart A; Hamza, Taye H; Hung, Albert Y; Hyman, Bradley T; Ivinson, Adrian J; Krainc, Dmitri; Latourelle, Jeanne C; Clark, Lorraine N; Marder, Karen; Martin, Eden R; Mayeux, Richard; Ross, Owen A; Scherzer, Clemens R; Simon, David K; Tanner, Caroline; Vance, Jeffery M; Wszolek, Zbigniew K; Zabetian, Cyrus P; Myers, Richard H; Payami, Haydeh; Scott, William K; Foroud, Tatiana

    2012-03-01

    Genome-wide association (GWAS) methods have identified genes contributing to Parkinson's disease (PD); we sought to identify additional genes associated with PD susceptibility. A 2-stage design was used. First, individual level genotypic data from 5 recent PD GWAS (Discovery Sample: 4,238 PD cases and 4,239 controls) were combined. Following imputation, a logistic regression model was employed in each dataset to test for association with PD susceptibility and results from each dataset were meta-analyzed. Second, 768 single-nucleotide polymorphisms (SNPs) were genotyped in an independent Replication Sample (3,738 cases and 2,111 controls). Genome-wide significance was reached for SNPs in SNCA (rs356165; G: odds ratio [OR]=1.37; p=9.3×10(-21)), MAPT (rs242559; C: OR=0.78; p=1.5×10(-10)), GAK/DGKQ (rs11248051; T: OR=1.35; p=8.2×10(-9)/rs11248060; T: OR=1.35; p=2.0×10(-9)), and the human leukocyte antigen (HLA) region (rs3129882; A: OR=0.83; p=1.2×10(-8)), which were previously reported. The Replication Sample confirmed the associations with SNCA, MAPT, and the HLA region and also with GBA (E326K; OR=1.71; p=5×10(-8) Combined Sample) (N370; OR=3.08; p=7×10(-5) Replication sample). A novel PD susceptibility locus, RIT2, on chromosome 18 (rs12456492; p=5×10(-5) Discovery Sample; p=1.52×10(-7) Replication sample; p=2×10(-10) Combined Sample) was replicated. Conditional analyses within each of the replicated regions identified distinct SNP associations within GBA and SNCA, suggesting that there may be multiple risk alleles within these genes. We identified a novel PD susceptibility locus, RIT2, replicated several previously identified loci, and identified more than 1 risk allele within SNCA and GBA. Copyright © 2012 American Neurological Association.

  15. Meta-analysis of Parkinson disease: Identification of a novel locus, RIT2

    PubMed Central

    Pankratz, Nathan; Beecham, Gary W.; DeStefano, Anita L.; Dawson, Ted M.; Doheny, Kimberly F.; Factor, Stewart A.; Hamza, Taye H.; Hung, Albert Y.; Hyman, Bradley T.; Ivinson, Adrian J.; Krainc, Dmitri; Latourelle, Jeanne C.; Clark, Lorraine N.; Marder, Karen; Martin, Eden R.; Mayeux, Richard; Ross, Owen A.; Scherzer, Clemens R.; Simon, David K.; Tanner, Caroline; Vance, Jeffery M.; Wszolek, Zbigniew K.; Zabetian, Cyrus P.; Myers, Richard H.; Payami, Haydeh; Scott, William K.; Foroud, Tatiana

    2011-01-01

    Objective Genome-wide association (GWAS) methods have identified genes contributing to Parkinson disease (PD); we sought to identify additional genes associated with PD susceptibility. Methods A two stage design was used. First, individual level genotypic data from five recent PD GWAS (Discovery Sample: 4,238 PD cases and 4,239 controls) were combined. Following imputation, a logistic regression model was employed in each dataset to test for association with PD susceptibility and results from each dataset were meta-analyzed. Second, 768 SNPs were genotyped in an independent Replication Sample (3,738 cases and 2,111 controls). Results Genome-wide significance was reached for SNPs in SNCA (rs356165, G: odds ratio (OR)=1.37; p=9.3 × 10−21), MAPT (rs242559, C: OR=0.78; p=1.5 × 10−10), GAK/DGKQ (rs11248051, T:OR=1.35; p=8.2 × 10−9/ rs11248060, T: OR=1.35; p=2.0×10−9), and the HLA region (rs3129882, A: OR=0.83; p=1.2 × 10−8), which were previously reported. The Replication Sample confirmed the associations with SNCA, MAPT, and the HLA region and also with GBA (E326K OR=1.71; p=5 × 10−8 Combined Sample) (N370 OR=3.08; p=7 × 10−5 Replication sample). A novel PD susceptibility locus, RIT2, on chromosome 18 (rs12456492; p=5 × 10−5 Discovery Sample; p=1.52 × 10−7 Replication sample; p=2 × 10−10 Combined Sample) was replicated. Conditional analyses within each of the replicated regions identified distinct SNP associations within GBA and SNCA, suggesting that there may be multiple risk alleles within these genes. Interpretation We identified a novel PD susceptibility locus, RIT2, replicated several previously identified loci, and identified more than one risk allele within SNCA and GBA. PMID:22451204

  16. Determination of fusarium mycotoxins in wheat, maize and animal feed using on-line clean-up with high resolution mass spectrometry.

    PubMed

    Ates, E; Mittendorf, K; Stroka, J; Senyuva, H

    2013-01-01

    An automated method involving on-line clean-up and analytical separation in a single run using TurboFlow™ reversed phase liquid chromatography coupled to a high resolution mass spectrometer has been developed for the simultaneous determination of deoxynivalenol, T2 toxin, HT2 toxin, zearalenone and fumonisins B1 and B2 in maize, wheat and animal feed. Detection was performed in full scan mode at a resolution of R = 100,000 full width at half maximum with high energy collision cell dissociation for the determination of fragment ions with a mass accuracy below 5 ppm. The extract from homogenised samples, after blending with a 0.1% aqueous mixture of 0.1% formic acid/acetonitrile (43:57) for 45 min, was injected directly onto the TurboFlow™ (TLX) column for automated on-line clean-up followed by analytical separation and accurate mass detection. The TurboFlow™ column enabled specific binding of target mycotoxins, whereas higher molecular weight compounds, like fats, proteins and other interferences with different chemical properties, were removed to waste. Single laboratory method validation was performed by spiking blank materials with mycotoxin standards. The recovery and repeatability was determined by spiking at three concentration levels (50, 100 and 200% of legislative limits) with six replicates. Average recovery, relative standard deviation and intermediate precision values were 71 to 120%, 1 to 19% and 4 to 19%, respectively. The method accuracy was confirmed with certified reference materials and participation in proficiency testing.

  17. Synthesis and characterization of UO(2)(2+)-ion imprinted polymer for selective extraction of UO(2)(2+).

    PubMed

    Singh, Dhruv K; Mishra, Shraddha

    2009-06-30

    Ion-imprinted polymers (IIPs) were prepared for uranyl ion (imprint ion) by formation of binary (salicylaldoxime (SALO) or 4-vinylpyridine (VP)) or ternary (salicylaldoxime and 4-vinylpyridine) complex in 2-methoxy ethanol (porogen) following copolymerization with methacrylic acid (MAA) as a functional monomer and ethylene glycol dimethacrylate (EGDMA) as crosslinking monomer using 2,2'-azobisisobutyronitrile as initiator. Control polymers (CPs) were also prepared under identical experimental conditions without using imprint ion. The above synthesized polymers were characterized by surface area measurement, microanalysis and FT-IR analysis techniques. The imprinted polymer formed with ternary complex of UO(2)(2+)-SALO-VP (1:2:2, IIP3) showed quantitative enrichment of uranyl ion from dilute aqueous solution and hence was chosen for detailed studies. The optimal pH for quantitative enrichment is 3.5-6.5. The adsorbed UO(2)(2+) was completely eluted with 10 mL of 1.0 M HCl. The retention capacity of IIP3 was found to be 0.559 mmol g(-1). Further, the distribution ratio and selectivity coefficients of uranium and other selected inorganic ions were also evaluated. Five replicate determinations of 25 microg L(-1) of uranium(VI) gave a mean absorbance of 0.032 with a relative standard deviation of 2.20%. The detection limit corresponding to three times the standard deviation of the blank was found to be 5 microg L(-1). IIP3 was tested for preconcentration of uranium(VI) from ground, river and sea water samples.

  18. Quantitation and detection of vanadium in biologic and pollution materials

    NASA Technical Reports Server (NTRS)

    Gordon, W. A.

    1974-01-01

    A review is presented of special considerations and methodology for determining vanadium in biological and air pollution materials. In addition to descriptions of specific analysis procedures, general sections are included on quantitation of analysis procedures, sample preparation, blanks, and methods of detection of vanadium. Most of the information presented is applicable to the determination of other trace elements in addition to vanadium.

  19. High-throughput imaging of heterogeneous cell organelles with an X-ray laser (CXIDB ID 25)

    DOE Data Explorer

    Hantke, Max, F.

    2014-11-17

    Preprocessed detector images that were used for the paper "High-throughput imaging of heterogeneous cell organelles with an X-ray laser". The CXI file contains the entire recorded data - including both hits and blanks. It also includes down-sampled images and LCLS machine parameters. Additionally, the Cheetah configuration file is attached that was used to create the pre-processed data.

  20. Benthic macrofauna data for San Francisco Bay, California, September 1986

    USGS Publications Warehouse

    Schemel, Laurence E.; Thompson, J.K.; Harmon, J.G.; Yost, B.T.

    1995-01-01

    Benthic macrofauna were collected during September 1986 to evaluate locations for long-term monitoring stations as part of the U.S. Geological Survey Regional Effects Monitoring Program in San Francisco Bay, California. Three to ten replicate samples were collected with a modified Van Veen sampler (0.05 m2 area) at ten locations. One box core sample (0.06 m2 area) was collected at seven to the ten locations. Six of the box core samples were split into an upper 10 cm sample and a deeper sample before analysis. Macrofauna specimens were identified to the lowest possible taxon, usually genus and species, then counted. An average of 88 percent of the benthic macrofauna specimens were identified to the species level. The fraction identified varied among stations from 54 to 98 percent. Nematodes and oligochaetes accounted for most of the unidentified specimens. Relative to the total number of species identified in five replicates at each location, an average of 90 percent of the species were collected with three replicates. In general, species with high to moderate abundances were present in all replicates, and species collected only after three or more replicates averaged less than one specimen per replicate. Results from the box cores showed that the dominant species were most abundant in the upper 10 cm, the depth of sediment that can be adequately sampled with a modified Van Veen sampler. On the basis of the number of species and their abundances at each location, seven of the ten locations were selected for sampling in the regular program, which began in March 1987.

  1. Low-level (submicromole) environmental 14C metrology

    NASA Astrophysics Data System (ADS)

    Currie, L. A.; Kessler, J. D.; Marolf, J. V.; McNichol, A. P.; Stuart, D. R.; Donoghue, J. C.; Donahue, D. J.; Burr, G. S.; Biddulph, D.

    2000-10-01

    Accelerator mass spectrometry (AMS) measurements of environmental 14C have been employed during the past decade at the several micromole level (tens of μg carbon), but advanced research in the atmospheric and marine sciences demands still higher (μg) sensitivity, an extreme example being the determination of 14C in elemental or "black" carbon (BC) at levels of 2-10 μg per kg of Greenland snow and ice (Currie et al., 1998). A fundamental limitation for 14C AMS is Poisson counting statistics, which sets in at about 1 μg modern-C. Using the small sample (25 μg) AMS target preparation facility at NOSAMS (Pearson et al., 1998), and the microsample combustion-dilution facility at NIST, we have demonstrated an intrinsic modern-C quantification limit ( mQ) of ca. 0.9 μg, based on a 1-parameter fit to the empirical AMS variance function. (For environmental 14C, the modern carbon quantification limit is defined as that mass ( mQ) corresponding to 10% relative standard deviation (rsd) for the fraction of modern carbon, σ( fM)/ fM.) Stringent control, required for quantitative dilution factors (DL), is achieved with the NIST on-line manometric/mass spectrometry facility that compensates also for unsuspected trace impurities from vigorous chemical processing (e.g., acid digestion). Our current combustion blank is trivial (mean: 0.16 ± 0.02 μg C, n=13) but lognormally distributed (dispersion [σ]: 0.07 ± 0.01 μg). An iterative numerical expression is introduced to assess the quantitative impacts of fossil and modern carbon blank components on mQ; and a new "clean chemistry" BC processing system is described for the minimization of such blanks. For the assay of soot carbon in Greenland snow/ice, the overall processing blank has been reduced from nearly 7 μg total carbon to less than 1 μg, and is undetectable for BC.

  2. Prediction of Supersonic Store Separation Characteristics Including Fuselage and Stores of Noncircular Cross Section. Volume III. Appendices A and B, Details of Program I.

    DTIC Science & Technology

    1980-11-01

    IZPT,ITH,IDEL,NTAP7,IAR,IAN,IUB, IGB(7) ,IVB,IU,IV,IW,IVA,IWA, ICP, IPHI,IYB,NAG,NAP,NAV,NAS, NASHK, NAFLD ,IAO,IDO,ISKO,TYIMI,IZIM,ISVN,ISKP,NRING,IROW...locations in blank common required in SOLVE NASHIK maximum locations in blank common required in BSHOCK NAFLD maximum locations in blank common

  3. Is psychology suffering from a replication crisis? What does "failure to replicate" really mean?

    PubMed

    Maxwell, Scott E; Lau, Michael Y; Howard, George S

    2015-09-01

    Psychology has recently been viewed as facing a replication crisis because efforts to replicate past study findings frequently do not show the same result. Often, the first study showed a statistically significant result but the replication does not. Questions then arise about whether the first study results were false positives, and whether the replication study correctly indicates that there is truly no effect after all. This article suggests these so-called failures to replicate may not be failures at all, but rather are the result of low statistical power in single replication studies, and the result of failure to appreciate the need for multiple replications in order to have enough power to identify true effects. We provide examples of these power problems and suggest some solutions using Bayesian statistics and meta-analysis. Although the need for multiple replication studies may frustrate those who would prefer quick answers to psychology's alleged crisis, the large sample sizes typically needed to provide firm evidence will almost always require concerted efforts from multiple investigators. As a result, it remains to be seen how many of the recently claimed failures to replicate will be supported or instead may turn out to be artifacts of inadequate sample sizes and single study replications. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  4. Evaluation of peak picking quality in LC-MS metabolomics data.

    PubMed

    Brodsky, Leonid; Moussaieff, Arieh; Shahaf, Nir; Aharoni, Asaph; Rogachev, Ilana

    2010-11-15

    The output of LC-MS metabolomics experiments consists of mass-peak intensities identified through a peak-picking/alignment procedure. Besides imperfections in biological samples and instrumentation, data accuracy is highly dependent on the applied algorithms and their parameters. Consequently, quality control (QC) is essential for further data analysis. Here, we present a QC approach that is based on discrepancies between replicate samples. First, the quantile normalization of per-sample log-signal distributions is applied to each group of biologically homogeneous samples. Next, the overall quality of each replicate group is characterized by the Z-transformed correlation coefficients between samples. This general QC allows a tuning of the procedure's parameters which minimizes the inter-replicate discrepancies in the generated output. Subsequently, an in-depth QC measure detects local neighborhoods on a template of aligned chromatograms that are enriched by divergences between intensity profiles of replicate samples. These neighborhoods are determined through a segmentation algorithm. The retention time (RT)-m/z positions of the neighborhoods with local divergences are indicative of either: incorrect alignment of chromatographic features, technical problems in the chromatograms, or to a true biological discrepancy between replicates for particular metabolites. We expect this method to aid in the accurate analysis of metabolomics data and in the development of new peak-picking/alignment procedures.

  5. Routine low-level monitoring of polar pesticides and pesticide degradates by HPLC/ESI-MS: Evaluating long-term performance

    USGS Publications Warehouse

    Furlong, E.T.; Martin, Jeffrey D.; Werner, S.L.; Gates, Paul M.

    2002-01-01

    The sensitivity and selective determination of polar pesticides were analyzed using high-performance liquid chromatography/electrospray ionization-mass spectrometry (HPLC/ESI-MS). The effects of multiple operators and instruments on method performance were evaluated using 440 pairs of fortified reagent-water and blank reagent-water samples. The influence of varying environmental matrices on recovery and precision were also analyzed using 200 fortified ambient water samples and duplicate ambient water samples. The results show that compound stability in filtered water was matrix-, chemical class- and compound-dependent which ranged from 1 day to 2 weeks.

  6. Lithographic qualification of high-transmission mask blank for 10nm node and beyond

    NASA Astrophysics Data System (ADS)

    Xu, Yongan; Faure, Tom; Viswanathan, Ramya; Lobb, Granger; Wistrom, Richard; Burns, Sean; Hu, Lin; Graur, Ioana; Bleiman, Ben; Fischer, Dan; Mignot, Yann; Sakamoto, Yoshifumi; Toda, Yusuke; Bolton, John; Bailey, Todd; Felix, Nelson; Arnold, John; Colburn, Matthew

    2016-04-01

    In this paper, we discuss the lithographic qualification of high transmission (High T) mask for Via and contact hole applications in 10nm node and beyond. First, the simulated MEEF and depth of focus (DoF) data are compared between the 6% and High T attnPSM masks with the transmission of High T mask blank varying from 12% to 20%. The 12% High T blank shows significantly better MEEF and larger DoF than those of 6% attnPSM mask blank, which are consistent with our wafer data. However, the simulations show no obvious advantage in MEEF and DoF when the blank transmittance is larger than 12%. From our wafer data, it has been seen that the common process window from High T mask is 40nm bigger than that from the 6% attnPSM mask. In the elongated bar structure with smaller aspect ratio, 1.26, the 12% High T mask shows significantly less develop CD pull back in the major direction. Compared to the High T mask, the optimized new illumination condition for 6% attnPSM shows limited improvement in MEEF and the DoF through pitch. In addition, by using the High T mask blank, we have also investigated the SRAF printing, side lobe printing and the resist profile through cross sections, and no patterning risk has been found for manufacturing. As part of this work new 12% High T mask blank materials and processes were developed, and a brief overview of key mask technology development results have been shared. Overall, it is concluded that the High T mask, 12% transmission, provides the most robust and extendable lithographic solution for 10nm node and beyond.

  7. Inspection of lithographic mask blanks for defects

    DOEpatents

    Sommargren, Gary E.

    2001-01-01

    A visible light method for detecting sub-100 nm size defects on mask blanks used for lithography. By using optical heterodyne techniques, detection of the scattered light can be significantly enhanced as compared to standard intensity detection methods. The invention is useful in the inspection of super-polished surfaces for isolated surface defects or particulate contamination and in the inspection of lithographic mask or reticle blanks for surface defects or bulk defects or for surface particulate contamination.

  8. FISH-detected delay in replication timing of mutated FMR1 alleles on both active and inactive X-chromosomes.

    PubMed

    Yeshaya, J; Shalgi, R; Shohat, M; Avivi, L

    1999-01-01

    X-chromosome inactivation and the size of the CGG repeat number are assumed to play a role in the clinical, physical, and behavioral phenotype of female carriers of a mutated FMR1 allele. In view of the tight relationship between replication timing and the expression of a given DNA sequence, we have examined the replication timing of FMR1 alleles on active and inactive X-chromosomes in cell samples (lymphocytes or amniocytes) of 25 females: 17 heterozygous for a mutated FMR1 allele with a trinucleotide repeat number varying from 58 to a few hundred, and eight homozygous for a wild-type allele. We have applied two-color fluorescence in situ hybridization (FISH) with FMR1 and X-chromosome alpha-satellite probes to interphase cells of the various genotypes: the alpha-satellite probe was used to distinguish between early replicating (active) and late replicating (inactive) X-chromosomes, and the FMR1 probe revealed the replication pattern of this locus. All samples, except one with a large trinucleotide expansion, showed an early replicating FMR1 allele on the active X-chromosome and a late replicating allele on the inactive X-chromosome. In samples of mutation carriers, both the early and the late alleles showed delayed replication compared with normal alleles, regardless of repeat size. We conclude therefore that: (1) the FMR1 locus is subjected to X-inactivation; (2) mutated FMR1 alleles, regardless of repeat size, replicate later than wild-type alleles on both the active and inactive X-chromosomes; and (3) the delaying effect of the trinucleotide expansion, even with a low repeat size, is superimposed on the delay in replication associated with X-inactivation.

  9. Theoretical Analysis on Mechanical Deformation of Membrane-Based Photomask Blanks

    NASA Astrophysics Data System (ADS)

    Marumoto, Kenji; Aya, Sunao; Yabe, Hedeki; Okada, Tatsunori; Sumitani, Hiroaki

    2012-04-01

    Membrane-based photomask is used in proximity X-ray lithography including that in LIGA (Lithographie, Galvanoformung und Abformung) process, and near-field photolithography. In this article, out-of-plane deformation (OPD) and in-plane displacement (IPD) of membrane-based photomask blanks are theoretically analyzed to obtain the mask blanks with flat front surface and low stress absorber film. First, we derived the equations of OPD and IPD for the processing steps of membrane-based photomask such as film deposition, back-etching and bonding, using a theory of symmetrical bending of circular plates with a coaxial circular hole and that of deformation of cylinder under hydrostatic pressure. The validity of the equations was proved by comparing the calculation results with experimental ones. Using these equations, we investigated the relation between the geometry of the mask blanks and the distortions generally, and gave the criterion to attain the flat front surface. Moreover, the absorber stress-bias required to obtain zero-stress on finished mask blanks was also calculated and it has been found that only little stress-bias was required for adequate hole size of support plate.

  10. Attentional Lapses in Attention-Deficit/Hyperactivity Disorder: Blank Rather Than Wandering Thoughts.

    PubMed

    Van den Driessche, Charlotte; Bastian, Mikaël; Peyre, Hugo; Stordeur, Coline; Acquaviva, Éric; Bahadori, Sara; Delorme, Richard; Sackur, Jérôme

    2017-10-01

    People with attention-deficit/hyperactivity disorder (ADHD) have difficulties sustaining their attention on external tasks. Such attentional lapses have often been characterized as the simple opposite of external sustained attention, but the different types of attentional lapses, and the subjective experiences to which they correspond, remain unspecified. In this study, we showed that unmedicated children (ages 6-12) with ADHD, when probed during a standard go/no-go task, reported more mind blanking (a mental state characterized by the absence of reportable content) than did control participants. This increase in mind blanking happened at the expense of both focused and wandering thoughts. We also found that methylphenidate reverted the level of mind blanking to baseline (i.e., the level of mind blanking reported by control children without ADHD). However, this restoration led to mind wandering more than to focused attention. In a second experiment, we extended these findings to adults who had subclinical ADHD. These results suggest that executive functions impaired in ADHD are required not only to sustain external attention but also to maintain an internal train of thought.

  11. An Artificial Turf-Based Surrogate Surface Collector for the Direct Measurement of Atmospheric Mercury Dry Deposition

    PubMed Central

    Hall, Naima L.; Dvonch, Joseph Timothy; Marsik, Frank J.; Barres, James A.; Landis, Matthew S.

    2017-01-01

    This paper describes the development of a new artificial turf surrogate surface (ATSS) sampler for use in the measurement of mercury (Hg) dry deposition. In contrast to many existing surrogate surface designs, the ATSS utilizes a three-dimensional deposition surface that may more closely mimic the physical structure of many natural surfaces than traditional flat surrogate surface designs (water, filter, greased Mylar film). The ATSS has been designed to overcome several complicating factors that can impact the integrity of samples with other direct measurement approaches by providing a passive system which can be deployed for both short and extended periods of time (days to weeks), and is not contaminated by precipitation and/or invalidated by strong winds. Performance characteristics including collocated precision, in-field procedural and laboratory blanks were evaluated. The results of these performance evaluations included a mean collocated precision of 9%, low blanks (0.8 ng), high extraction efficiency (97%–103%), and a quantitative matrix spike recovery (100%). PMID:28208603

  12. Homogeneity of the coefficient of linear thermal expansion of ZERODUR: a review of a decade of evaluations

    NASA Astrophysics Data System (ADS)

    Jedamzik, Ralf; Westerhoff, Thomas

    2017-09-01

    The coefficient of thermal expansion (CTE) and its spatial homogeneity from small to large formats is the most important property of ZERODUR. Since more than a decade SCHOTT has documented the excellent CTE homogeneity. It started with reviews of past astronomical telescope projects like the VLT, Keck and GTC mirror blanks and continued with dedicated evaluations of the production. In recent years, extensive CTE measurements on samples cut from randomly selected single ZERODUR parts in meter size and formats of arbitrary shape, large production boules and even 4 m sized blanks have demonstrated the excellent CTE homogeneity in production. The published homogeneity data shows single ppb/K peak to valley CTE variations on medium spatial scale of several cm down to small spatial scale of only a few mm mostly at the limit of the measurement reproducibility. This review paper summarizes the results also in respect to the increased CTE measurement accuracy over the last decade of ZERODUR production.

  13. Multilaboratory Validation of First Action Method 2016.04 for Determination of Four Arsenic Species in Fruit Juice by High-Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometry.

    PubMed

    Kubachka, Kevin; Heitkemper, Douglas T; Conklin, Sean

    2017-07-01

    Before being designated AOAC First Action Official MethodSM 2016.04, the U.S. Food and Drug Administration's method, EAM 4.10 High Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometric Determination of Four Arsenic Species in Fruit Juice, underwent both a single-laboratory validation and a multilaboratory validation (MLV) study. Three federal and five state regulatory laboratories participated in the MLV study, which is the primary focus of this manuscript. The method was validated for inorganic arsenic (iAs) measured as the sum of the two iAs species arsenite [As(III)] and arsenate [As(V)], dimethylarsinic acid (DMA), and monomethylarsonic acid (MMA) by analyses of 13 juice samples, including three apple juice, three apple juice concentrate, four grape juice, and three pear juice samples. In addition, two water Standard Reference Materials (SRMs) were analyzed. The method LODs and LOQs obtained among the eight laboratories were approximately 0.3 and 2 ng/g, respectively, for each of the analytes and were adequate for the intended purpose of the method. Each laboratory analyzed method blanks, fortified method blanks, reference materials, triplicate portions of each juice sample, and duplicate fortified juice samples (one for each matrix type) at three fortification levels. In general, repeatability and reproducibility of the method was ≤15% RSD for each species present at a concentration >LOQ. The average recovery of fortified analytes for all laboratories ranged from 98 to 104% iAs, DMA, and MMA for all four juice sample matrixes. The average iAs results for SRMs 1640a and 1643e agreed within the range of 96-98% of certified values for total arsenic.

  14. Optimization and application of an extraction procedure to determine drugs of abuse in solid environmental matrices of Turia River Basin

    NASA Astrophysics Data System (ADS)

    Andres, Maria Jesus; Alvarez, Rodrigo; Andreu, Vicente; Pico, Yolanda

    2015-04-01

    After their consumption, drug of abuse are excreted through urine or faeces, as parent compound or as secondary metabolites that arrive to wastewater treatment plants. Accordingly, the incomplete removal of these compounds in the treatment plants could release them into environmental compartments [1]. This scenario needs attention from an ecotoxicological perspective because their possible negative effects [2]. The aim of this study is to optimize and apply a solvent extraction and solid phase clean-up methodology to obtain a valid procedure for the extraction of these compounds in different solid matrices. Amphetamine, methamphetamine, ethylamphetamine, ecstasy, ethylone, bk-MMBDB and MBDB belong to phenylethylamine group; codeine and ketamine belong to opioid and phencyclidine group, respectively, and benzoylecgonine is the major excreted metabolite of the alkaloid cocaine. To optimize the method to determinate drugs of abuse in environmental solid matrices, two replicates and one blank were prepared for each sample of sediment. They were prepared by adding 1 g of sediment sample, 5 mL of buffer (methanol-Mc Ilvaine 50:50) and internal standard to obtain a final concentration in the extract of 25 ng/g. Also standards of drugs of abuse were added to the replicates to obtain a final concentration of 100 ng/g. Then all samples were shaken, sonicated and centrifuged and the supernatant was separated and placed in a 250 mL volumetric flask, which was filled the rest with distilled water. SPE was carried out with Strata-X cartridges and 250 mL of sample were passed through them. The extracts were eluted with 6 mL of methanol, evaporated to dryness and reconstituted in 1 mL of methanol-water 1:9. One of the replicates was filtrated through 0.22 μm pore size and the others were not. The samples were determined by liquid chromatography triple quadrupole mass spectrometry (LC-QqQ-MS/MS) using an electrospray ionization source (ESI) in positive ionization mode. The results show that extraction recoveries of phenylethylamine group were from 39.3 to 92.4%. For codeine and ketamine, the recoveries ranged from 44.4 to 90.6% and from 61.3 to 79.5%, respectively. Benzoylecgonine presented recoveries ranged from 72 to 77.5%. The precision of the method was below 20% for all the compounds. The method was applied to determine these drugs of abuse in sediments of the Turia River Basin. Ecstasy, codeine, ketamine and benzoylecgonine were found at concentrations ranging from 0.22 ng/g to 25 ng/g in 6 sampling points. Very limited information exists on the presence of drugs of abuse in environmental matrices. Nothing can be concluded about the differences between the recoveries obtained in unfiltered and filtered samples because they do not follow any trend. These results confirm the reliability of the method as well as its suitability to be applied in environmental studies. Acknowledgements This work has been supported by the Spanish Ministry of Economy and Competitiveness trough the project SCARCE-CDS 2009-0065, CGL 2011-29703-C02-01 and CGL 2011-29703-C02-02. MJ Andrés Costa also acknowledges to this Ministry the FPI grant to perform her PhD. References [1] T.H. Boles, M.J.M. Wells, Analysis of amphetamine and methamphetamine as emerging pollutants in wastewater and wastewater-impacted streams, Journal of Chromatography A 1217 (2010) 2561. [2] C. Postigo, M.J. López de Alda, D. Barceló, Drugs of abuse and their metabolites in the Ebro River basin: Occurrence in sewage and surface water, sewage treatment plants removal efficiency, and collective drug usage estimation Environment International 36 (2010) 75.

  15. Effect of ionization suppression by trace impurities in mobile phase water on the accuracy of quantification by high-performance liquid chromatography/mass spectrometry.

    PubMed

    Herath, H M D R; Shaw, P N; Cabot, P; Hewavitharana, A K

    2010-06-15

    The high-performance liquid chromatography (HPLC) column is capable of enrichment/pre-concentration of trace impurities in the mobile phase during the column equilibration, prior to sample injection and elution. These impurities elute during gradient elution and result in significant chromatographic peaks. Three types of purified water were tested for their impurity levels, and hence their performances as mobile phase, in HPLC followed by total ion current (TIC) mode of MS. Two types of HPLC-grade water produced 3-4 significant peaks in solvent blanks while LC/MS-grade water produced no peaks (although peaks were produced by LC/MS-grade water also after a few days of standing). None of the three waters produced peaks in HPLC followed by UV-Vis detection. These peaks, if co-eluted with analyte, are capable of suppressing or enhancing the analyte signal in a MS detector. As it is not common practice to run solvent blanks in TIC mode, when quantification is commonly carried out using single ion monitoring (SIM) or single or multiple reaction monitoring (SRM or MRM), the effect of co-eluting impurities on the analyte signal and hence on the accuracy of the results is often unknown to the analyst. Running solvent blanks in TIC mode, regardless of the MS mode used for quantification, is essential in order to detect this problem and to take subsequent precautions. Copyright (c) 2010 John Wiley & Sons, Ltd.

  16. The Development of an Officer Training School Board Score Prediction Method Using a Multi-Board Approach

    DTIC Science & Technology

    1991-03-01

    forms: ". ..application blanks, biographical inventories , interviews, work sample tests, and intelligence, aptitude, and personality tests" (1:11...the grouping method, 3) the task method, and 4) the knowledge , skills, abilities (KSA) method. The point method of measuring training/experience assigns... knowledge , skills, abilities, and other characteristics which relate specifically to each job element (3:131). Interview. According to N. Schmitt

  17. A Novel Hydrogel-Based Biosampling Approach

    DTIC Science & Technology

    2016-03-01

    MONITORING AGENCY NAME(S) AND ADDRESS(ES) U.S. Army Edgewood Chemical Biological Center Seedling Program, APG, MD 21010-5424 10. SPONSOR/MONITOR’S...Std. Z39.18 ii Blank   iii PREFACE The work described in this report was authorized under the U.S. Army Edgewood Chemical Biological...a complex area of intensive, ongoing research. After a biorelease event, sampling is at the core of all pre- and post- decontamination analyses

  18. Image Descriptors for Displays

    DTIC Science & Technology

    1975-03-01

    sampled with composite blanking signal; (c) signal in (a) formed into composite video signal ... 24 3. Power spectral density of the signals shown in...Curve A: composite video signal formed from 20 Hz to 2.5 MH.i band-limited, Gaussian white noise. Curve B: average spectrum of off-the-air video...previously. Our experimental procedure was the following. Off-the-air television signals broadcast on VHP channels were analyzed with a commercially

  19. Fluid Structure Interaction Effects on Composites Under Low Velocity Impact

    DTIC Science & Technology

    2012-06-01

    Nanotubes ( MWCNTs ) and the second had no reinforcements at the interface layer in front of the pre-cracks. Output from both tests was recorded using...these samples were tested. The first was reinforced with Multi-Walled Carbon Nanotubes ( MWCNTs ) and the second had no reinforcements at the interface...Ethyl Ketone Peroxide MWCNT Multi-Walled Carbon Nanotube VARTM Vacuum-Assisted Resin Transfer Molding xiv THIS PAGE INTENTIONALLY LEFT BLANK

  20. Prototypes of Cognitive Measures for Air Force Officers: Test Development and Item Banking

    DTIC Science & Technology

    1990-05-01

    with the complexity of the relationship. Relationships may be in terms of shape, size, dimensionality, area of embeddedness , rotation, blank/shaded...administration were used. Test directions were read from the booklet. Demographics and test responses were recorded on a machine-scannable answer sheet...as demographic information would be needed to determine whether sample characteristics accounted for the differences in mean scores for NC, FA, and WD

  1. Improved electron probe microanalysis of trace elements in quartz

    USGS Publications Warehouse

    Donovan, John J.; Lowers, Heather; Rusk, Brian G.

    2011-01-01

    Quartz occurs in a wide range of geologic environments throughout the Earth's crust. The concentration and distribution of trace elements in quartz provide information such as temperature and other physical conditions of formation. Trace element analyses with modern electron-probe microanalysis (EPMA) instruments can achieve 99% confidence detection of ~100 ppm with fairly minimal effort for many elements in samples of low to moderate average atomic number such as many common oxides and silicates. However, trace element measurements below 100 ppm in many materials are limited, not only by the precision of the background measurement, but also by the accuracy with which background levels are determined. A new "blank" correction algorithm has been developed and tested on both Cameca and JEOL instruments, which applies a quantitative correction to the emitted X-ray intensities during the iteration of the sample matrix correction based on a zero level (or known trace) abundance calibration standard. This iterated blank correction, when combined with improved background fit models, and an "aggregate" intensity calculation utilizing multiple spectrometer intensities in software for greater geometric efficiency, yields a detection limit of 2 to 3 ppm for Ti and 6 to 7 ppm for Al in quartz at 99% t-test confidence with similar levels for absolute accuracy.

  2. Attenuated phase-shift mask (PSM) blanks for flat panel display

    NASA Astrophysics Data System (ADS)

    Kageyama, Kagehiro; Mochizuki, Satoru; Yamakawa, Hiroyuki; Uchida, Shigeru

    2015-10-01

    The fine pattern exposure techniques are required for Flat Panel display applications as smart phone, tablet PC recently. The attenuated phase shift masks (PSM) are being used for ArF and KrF photomask lithography technique for high end pattern Semiconductor applications. We developed CrOx based large size PSM blanks that has good uniformity on optical characteristics for FPD applications. We report the basic optical characteristics and uniformity, stability data of large sized CrOx PSM blanks.

  3. Quantifying viruses and bacteria in wastewater—Results, interpretation methods, and quality control

    USGS Publications Warehouse

    Francy, Donna S.; Stelzer, Erin A.; Bushon, Rebecca N.; Brady, Amie M.G.; Mailot, Brian E.; Spencer, Susan K.; Borchardt, Mark A.; Elber, Ashley G.; Riddell, Kimberly R.; Gellner, Terry M.

    2011-01-01

    Membrane bioreactors (MBR), used for wastewater treatment in Ohio and elsewhere in the United States, have pore sizes small enough to theoretically reduce concentrations of protozoa and bacteria, but not viruses. Sampling for viruses in wastewater is seldom done and not required. Instead, the bacterial indicators Escherichia coli (E. coli) and fecal coliforms are the required microbial measures of effluents for wastewater-discharge permits. Information is needed on the effectiveness of MBRs in removing human enteric viruses from wastewaters, particularly as compared to conventional wastewater treatment before and after disinfection. A total of 73 regular and 28 quality-control (QC) samples were collected at three MBR and two conventional wastewater plants in Ohio during 23 regular and 3 QC sampling trips in 2008-10. Samples were collected at various stages in the treatment processes and analyzed for bacterial indicators E. coli, fecal coliforms, and enterococci by membrane filtration; somatic and F-specific coliphage by the single agar layer (SAL) method; adenovirus, enterovirus, norovirus GI and GII, rotavirus, and hepatitis A virus by molecular methods; and viruses by cell culture. While addressing the main objective of the study-comparing removal of viruses and bacterial indicators in MBR and conventional plants-it was realized that work was needed to identify data analysis and quantification methods for interpreting enteric virus and QC data. Therefore, methods for quantifying viruses, qualifying results, and applying QC data to interpretations are described in this report. During each regular sampling trip, samples were collected (1) before conventional or MBR treatment (post-preliminary), (2) after secondary or MBR treatment (post-secondary or post-MBR), (3) after tertiary treatment (one conventional plant only), and (4) after disinfection (post-disinfection). Glass-wool fiber filtration was used to concentrate enteric viruses from large volumes, and small volume grab samples were collected for direct-plating analyses for bacterial indicators and coliphage. After filtration, the viruses were eluted from the filter and further concentrated. The final concentrated sample volume (FCSV) was used for enteric virus analysis by use of two methods-cell culture and a molecular method, polymerase chain reaction (PCR). Quantitative PCR (qPCR) for DNA viruses and quantitative reverse-transcriptase PCR (qRT-PCR) for RNA viruses were used in this study. To support data interpretations, the assay limit of detection (ALOD) was set for each virus assay and used to determine sample reporting limits (SRLs). For qPCR and qRT-PCR the ALOD was an estimated value because it was not established according to established method detection limit procedures. The SRLs were different for each sample because effective sample volumes (the volume of the original sample that was actually used in each analysis) were different for each sample. Effective sample volumes were much less than the original sample volumes because of reductions from processing steps and (or) from when dilutions were made to minimize the effects from PCR-inhibiting substances. Codes were used to further qualify the virus data and indicate the level of uncertainty associated with each measurement. Quality-control samples were used to support data interpretations. Field and laboratory blanks for bacteria, coliphage, and enteric viruses were all below detection, indicating that it was unlikely that samples were contaminated from equipment or processing procedures. The absolute value log differences (AVLDs) between concurrent replicate pairs were calculated to identify the variability associated with each measurement. For bacterial indicators and coliphage, the AVLD results indicated that concentrations <10 colony-forming units or plaque-forming units per 100 mL can differ between replicates by as much as 1 log, whereas higher concentrations can differ by as much as 0.3 log. The AVLD results for viruses indicated that differences between replicates can be as great as 1.2 log genomic copies per liter, regardless of the concentration of virus. Relatively large differences in molecular results for viruses between replicate pairs were likely due to lack of precision for samples with small effective volumes. Concentrations of E. coli, fecal coliforms, enterococci, and somatic and F-specific coliphage in post-secondary and post-tertiary samples in conventional plants were higher than those in post-MBR samples. In post-MBR and post-secondary samples, concentrations of somatic coliphage were higher than F-specific coliphage. In post-disinfection samples from two MBR plants (the third MBR plant had operational issues) and the ultraviolet conventional plant, concentrations for all bacterial indicators and coliphage were near or below detection; from the chlorine conventional plant, concentrations in post-disinfection samples were in the single or double digits. All of the plants met the National Pollutant Discharge Elimination System required effluent limits established for fecal coliforms. Norovirus GII and hepatitis A virus were not detected in any samples, and rotavirus was detected in one sample but could not be quantified. Adenovirus was found in 100 percent, enterovirus in over one-half, and norovirus GI in about one-half of post-preliminary wastewater samples. Adenovirus and enterovirus were detected throughout the treatment processes, and norovirus GI was detected less often than the other two enteric viruses. Culturable viruses were detected in post-preliminary samples and in only two post-treatment samples from the plant with operational issues.

  4. Addressing the "Replication Crisis": Using Original Studies to Design Replication Studies with Appropriate Statistical Power.

    PubMed

    Anderson, Samantha F; Maxwell, Scott E

    2017-01-01

    Psychology is undergoing a replication crisis. The discussion surrounding this crisis has centered on mistrust of previous findings. Researchers planning replication studies often use the original study sample effect size as the basis for sample size planning. However, this strategy ignores uncertainty and publication bias in estimated effect sizes, resulting in overly optimistic calculations. A psychologist who intends to obtain power of .80 in the replication study, and performs calculations accordingly, may have an actual power lower than .80. We performed simulations to reveal the magnitude of the difference between actual and intended power based on common sample size planning strategies and assessed the performance of methods that aim to correct for effect size uncertainty and/or bias. Our results imply that even if original studies reflect actual phenomena and were conducted in the absence of questionable research practices, popular approaches to designing replication studies may result in a low success rate, especially if the original study is underpowered. Methods correcting for bias and/or uncertainty generally had higher actual power, but were not a panacea for an underpowered original study. Thus, it becomes imperative that 1) original studies are adequately powered and 2) replication studies are designed with methods that are more likely to yield the intended level of power.

  5. Thresher: an improved algorithm for peak height thresholding of microbial community profiles.

    PubMed

    Starke, Verena; Steele, Andrew

    2014-11-15

    This article presents Thresher, an improved technique for finding peak height thresholds for automated rRNA intergenic spacer analysis (ARISA) profiles. We argue that thresholds must be sample dependent, taking community richness into account. In most previous fragment analyses, a common threshold is applied to all samples simultaneously, ignoring richness variations among samples and thereby compromising cross-sample comparison. Our technique solves this problem, and at the same time provides a robust method for outlier rejection, selecting for removal any replicate pairs that are not valid replicates. Thresholds are calculated individually for each replicate in a pair, and separately for each sample. The thresholds are selected to be the ones that minimize the dissimilarity between the replicates after thresholding. If a choice of threshold results in the two replicates in a pair failing a quantitative test of similarity, either that threshold or that sample must be rejected. We compare thresholded ARISA results with sequencing results, and demonstrate that the Thresher algorithm outperforms conventional thresholding techniques. The software is implemented in R, and the code is available at http://verenastarke.wordpress.com or by contacting the author. vstarke@ciw.edu or http://verenastarke.wordpress.com Supplementary data are available at Bioinformatics online. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  6. Maxwell-Wagner Effect Applied to Microwave-Induced Self-Ignition: A Novel Approach for Carbon-Based Materials.

    PubMed

    Bizzi, Cezar A; Cruz, Sandra M; Schmidt, Lucas; Burrow, Robert A; Barin, Juliano S; Paniz, Jose N G; Flores, Erico M M

    2018-04-03

    A new method for analytical applications based on the Maxwell-Wagner effect is proposed. Considering the interaction of carbonaceous materials with an electromagnetic field in the microwave frequency range, a very fast heating is observed due to interfacial polarization that results in localized microplasma formation. Such effect was evaluated in this work using a monomode microwave system, and temperature was recorded using an infrared camera. For analytical applications, a closed reactor under oxygen pressure was evaluated. The combination of high temperature and oxidant atmosphere resulted in a very effective self-ignition reaction of sample, allowing its use as sample preparation procedure for further elemental analysis. After optimization, a high sample mass (up to 600 mg of coal and graphite) was efficiently digested using only 4 mol L -1 HNO 3 as absorbing solution. Several elements (Ba, Ca, Fe, K, Li, Mg, Na, and Zn) were determined by inductively coupled plasma optical emission spectrometry (ICP-OES). Accuracy was evaluated by using a certified reference material (NIST 1632b). Blanks were negligible, and only a diluted solution was required for analytes absorption preventing residue generation and making the proposed method in agreement with green chemistry recommendations. The feasibility of the proposed method for hard-to-digest materials, the minimization of reagent consumption, and the possibility of multi elemental analysis with lower blanks and better limits of detection can be considered as the main advantages of this method.

  7. Replicability and Robustness of GWAS for Behavioral Traits

    PubMed Central

    Rietveld, Cornelius A.; Conley, Dalton; Eriksson, Nicholas; Esko, Tõnu; Medland, Sarah E.; Vinkhuyzen, Anna A.E.; Yang, Jian; Boardman, Jason D.; Chabris, Christopher F.; Dawes, Christopher T.; Domingue, Benjamin W.; Hinds, David A.; Johannesson, Magnus; Kiefer, Amy K.; Laibson, David; Magnusson, Patrik K. E.; Mountain, Joanna L.; Oskarsson, Sven; Rostapshova, Olga; Teumer, Alexander; Tung, Joyce Y.; Visscher, Peter M.; Benjamin, Daniel J.; Cesarini, David; Koellinger, Philipp D.

    2015-01-01

    A recent genome-wide association study (GWAS) of educational attainment identified three single-nucleotide polymorphisms (SNPs) that, despite their small effect sizes (each R2 ≈ 0.02%), reached genome-wide significance (p < 5×10−8) in a large discovery sample and replicated in an independent sample (p < 0.05). The study also reported associations between educational attainment and indices of SNPs called “polygenic scores.” We evaluate the robustness of these findings. Study 1 finds that all three SNPs replicate in another large (N = 34,428) independent sample. We also find that the scores remain predictive (R2 ≈ 2%) with stringent controls for stratification (Study 2) and in new within-family analyses (Study 3). Our results show that large and therefore well-powered GWASs can identify replicable genetic associations with behavioral traits. The small effect sizes of individual SNPs are likely to be a major contributing explanation for the striking contrast between our results and the disappointing replication record of most candidate gene studies. PMID:25287667

  8. Replication and contradiction of highly cited research papers in psychiatry: 10-year follow-up.

    PubMed

    Tajika, Aran; Ogawa, Yusuke; Takeshima, Nozomi; Hayasaka, Yu; Furukawa, Toshi A

    2015-10-01

    Contradictions and initial overestimates are not unusual among highly cited studies. However, this issue has not been researched in psychiatry. Aims: To assess how highly cited studies in psychiatry are replicated by subsequent studies. We selected highly cited studies claiming effective psychiatric treatments in the years 2000 through 2002. For each of these studies we searched for subsequent studies with a better-controlled design, or with a similar design but a larger sample. Among 83 articles recommending effective interventions, 40 had not been subject to any attempt at replication, 16 were contradicted, 11 were found to have substantially smaller effects and only 16 were replicated. The standardised mean differences of the initial studies were overestimated by 132%. Studies with a total sample size of 100 or more tended to produce replicable results. Caution is needed when a study with a small sample size reports a large effect. © The Royal College of Psychiatrists 2015.

  9. Analytical method validation to evaluate dithiocarbamates degradation in biobeds in South of Brazil.

    PubMed

    Vareli, Catiucia S; Pizzutti, Ionara R; Gebler, Luciano; Cardoso, Carmem D; Gai, Daniela S H; Fontana, Marlos E Z

    2018-07-01

    In order to evaluate the efficiency of biobeds on DTC degradation, the aim of this study was to apply, optimize and validate a method to determine dithiocarbamate (mancozeb) in biobeds using gas chromatography-tandem mass spectrometry (GC-MS). The DTC pesticide mancozeb was hydrolysed in a tin (II) chloride solution at 1.5% in HCl (4 mol L -1 ), during 1 h in a water bath at 80 °C, and the CS 2 formed was extracted in isooctane. After cooling, 1 mL of the organic layer was transferred to an auto sampler vial and analyzed by GC-MS. A complete validation study was performed and the following parameters were assessed: linearity of the analytical curve (r 2 ), estimated method and instrument limits of detection and limits of quantification (LODm, LODi, LOQm and LOQi, respectively), accuracy (recovery%), precision (RSD%) and matrix effects. Recovery experiments were carried out with a standard spiking solution of the DTC pesticide thiram. Blank biobed (biomixture) samples were spiked at the three levels corresponding to the CS 2 concentrations of 1, 3 and 5 mg kg -1 , with seven replicates each (n = 7). The method presented satisfactory accuracy, with recoveries within the range of 89-96% and RSD ≤ 11%. The analytical curves were linear in the concentration range of 0.05-10 µg CS 2 mL -1 (r 2 > 0.9946). LODm and LOQm were 0.1 and 0.5 mg CS 2 kg -1 , respectively, and the calculated matrix effects were not significant (≤ 20%). The validated method was applied to 80 samples (biomixture), from sixteen different biobeds (collected at five sampling times) during fourteen months. Ten percent of samples presented CS 2 concentration below the LOD (0.1 mg CS 2 kg -1 ) and 49% of them showed results below the LOQ (0.5 mg CS 2 kg -1 ), which demonstrates the biobeds capability to degrade DTC. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Evaluation on determination of iodine in coal by energy dispersive X-ray fluorescence

    USGS Publications Warehouse

    Wang, B.; Jackson, J.C.; Palmer, C.; Zheng, B.; Finkelman, R.B.

    2005-01-01

    A quick and inexpensive method of relative high iodine determination from coal samples was evaluated. Energy dispersive X-ray fluorescence (EDXRF) provided a detection limit of about 14 ppm (3 times of standard deviations of the blank sample), without any complex sample preparation. An analytical relative standard deviation of 16% was readily attainable for coal samples. Under optimum conditions, coal samples with iodine concentrations higher than 5 ppm can be determined using this EDXRF method. For the time being, due to the general iodine concentrations of coal samples lower than 5 ppm, except for some high iodine content coal, this method can not effectively been used for iodine determination. More work needed to meet the requirement of determination of iodine from coal samples for this method. Copyright ?? 2005 by The Geochemical Society of Japan.

  11. External quality assurance project report for the National Atmospheric Deposition Program’s National Trends Network and Mercury Deposition Network, 2015–16

    USGS Publications Warehouse

    Wetherbee, Gregory A.; Martin, RoseAnn

    2018-06-29

    The U.S. Geological Survey Precipitation Chemistry Quality Assurance project operated five distinct programs to provide external quality assurance monitoring for the National Atmospheric Deposition Program’s (NADP) National Trends Network and Mercury Deposition Network during 2015–16. The National Trends Network programs include (1) a field audit program to evaluate sample contamination and stability, (2) an interlaboratory comparison program to evaluate analytical laboratory performance, and (3) a colocated sampler program to evaluate bias and variability attributed to automated precipitation samplers. The Mercury Deposition Network programs include the (4) system blank program and (5) an interlaboratory comparison program. The results indicate that NADP data continue to be of sufficient quality for the analysis of spatial distributions and time trends for chemical constituents in wet deposition.The field audit program results indicate increased sample contamination for calcium, magnesium, and potassium relative to 2010 levels, and slight fluctuation in sodium contamination. Nitrate contamination levels dropped slightly during 2014–16, and chloride contamination leveled off between 2007 and 2016. Sulfate contamination is similar to the 2000 level. Hydrogen ion contamination has steadily decreased since 2012. Losses of ammonium and nitrate resulting from potential sample instability were negligible.The NADP Central Analytical Laboratory produced interlaboratory comparison results with low bias and variability compared to other domestic and international laboratories that support atmospheric deposition monitoring. Significant absolute bias above the magnitudes of the detection limits was observed for nitrate and sulfate concentrations, but no analyte determinations exceeded the detection limits for blanks.Colocated sampler program results from dissimilar colocated collectors indicate that the retrofit of the National Trends Network with N-CON Systems Company, Inc. precipitation collectors could cause substantial shifts in NADP annual deposition (concentration multiplied by depth) values. Median weekly relative percent differences for analyte concentrations ranged from -4 to +76 percent for cations, from 5 to 6 percent for ammonium, from +14 to +25 percent for anions, and from -21 to +8 percent for hydrogen ion contamination. By comparison, weekly absolute concentration differences for paired identical N-CON Systems Company, Inc., collectors ranged from 4–22 percent for cations; 2–9 percent for anions; 4–5 percent for ammonium; and 13–14 percent for hydrogen ion contamination. The N-CON Systems Company, Inc. collector caught more precipitation than the Aerochem Metrics Model 301 collector (ACM) at the WA99/99WA sites, but it typically caught slightly less precipitation than the ACM at ND11/11ND, sites which receive more wind and snow than WA99/99WA.Paired, identical OTT Pluvio-2 and ETI Noah IV precipitation gages were operated at the same sites. Median absolute percent differences for daily measured precipitation depths ranged from 0 to 7 percent. Annual absolute differences ranged from 0.08 percent (ETI Noah IV precipitation gages) to 11 percent (OTT Pluvio-2 precipitation gages).The Mercury Deposition Network programs include the system blank program and an interlaboratory comparison program. System blank results indicate that maximum total mercury contamination concentrations in samples were less than the third percentile of all Mercury Deposition Network sample concentrations (1.098 nanograms per liter; ng/L). The Mercury Analytical Laboratory produced chemical concentration results with low bias and variability compared with other domestic and international laboratories that support atmospheric-deposition monitoring. The laboratory’s performance results indicate a +1-ng/L shift in bias between 2015 (-0.4 ng/L) and 2016 (+0.5 ng/L).

  12. Rapid iconic erasure without masking.

    PubMed

    Tijus, Charles Albert; Reeves, Adam

    2004-01-01

    We report on the erasure of the iconic memory of an array of 12 black letters flashed on a continuously- present white field. Erasure is accomplished by replacing the 16 ms letter array (frame 1) with a blank white frame for 16 ms (frame 2). The letter array returns in frame 3, with from one to six letters missing. Report of the missing letters is accurate without the blank white frame but is impoverished with it, as if interposing the blank erases the icon. Erasure occurs without any obvious luminance masking, 'mud splashes', pattern masking (backward, forward, or metacontrast), lateral masking, or masking by object substitution. Erasure is greatly decreased if the blank is presented one frame earlier or later. We speculate that erasure is due to a rapid reset of the icon produced by an informational mis-match.

  13. rMATS: robust and flexible detection of differential alternative splicing from replicate RNA-Seq data.

    PubMed

    Shen, Shihao; Park, Juw Won; Lu, Zhi-xiang; Lin, Lan; Henry, Michael D; Wu, Ying Nian; Zhou, Qing; Xing, Yi

    2014-12-23

    Ultra-deep RNA sequencing (RNA-Seq) has become a powerful approach for genome-wide analysis of pre-mRNA alternative splicing. We previously developed multivariate analysis of transcript splicing (MATS), a statistical method for detecting differential alternative splicing between two RNA-Seq samples. Here we describe a new statistical model and computer program, replicate MATS (rMATS), designed for detection of differential alternative splicing from replicate RNA-Seq data. rMATS uses a hierarchical model to simultaneously account for sampling uncertainty in individual replicates and variability among replicates. In addition to the analysis of unpaired replicates, rMATS also includes a model specifically designed for paired replicates between sample groups. The hypothesis-testing framework of rMATS is flexible and can assess the statistical significance over any user-defined magnitude of splicing change. The performance of rMATS is evaluated by the analysis of simulated and real RNA-Seq data. rMATS outperformed two existing methods for replicate RNA-Seq data in all simulation settings, and RT-PCR yielded a high validation rate (94%) in an RNA-Seq dataset of prostate cancer cell lines. Our data also provide guiding principles for designing RNA-Seq studies of alternative splicing. We demonstrate that it is essential to incorporate biological replicates in the study design. Of note, pooling RNAs or merging RNA-Seq data from multiple replicates is not an effective approach to account for variability, and the result is particularly sensitive to outliers. The rMATS source code is freely available at rnaseq-mats.sourceforge.net/. As the popularity of RNA-Seq continues to grow, we expect rMATS will be useful for studies of alternative splicing in diverse RNA-Seq projects.

  14. Social Dating Goals in Female College Students: Failure to Replicate in a Diverse Sample

    ERIC Educational Resources Information Center

    Killeya-Jones, Ley A.

    2004-01-01

    This article reports a failure to replicate aspects of the Social Dating Goals Scale (SDGS; Sanderson & Cantor, 1995) with an ethnically diverse group of female college students. The SDGS was developed and validated with predominantly White samples. In the present study, a diverse sample of 82 Asian, Black, Hispanic and White female college…

  15. Groundwater-quality data in seven GAMA study units: results from initial sampling, 2004-2005, and resampling, 2007-2008, of wells: California GAMA Program Priority Basin Project

    USGS Publications Warehouse

    Kent, Robert; Belitz, Kenneth; Fram, Miranda S.

    2014-01-01

    The Priority Basin Project (PBP) of the Groundwater Ambient Monitoring and Assessment (GAMA) Program was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The GAMA-PBP began sampling, primarily public supply wells in May 2004. By the end of February 2006, seven (of what would eventually be 35) study units had been sampled over a wide area of the State. Selected wells in these first seven study units were resampled for water quality from August 2007 to November 2008 as part of an assessment of temporal trends in water quality by the GAMA-PBP. The initial sampling was designed to provide a spatially unbiased assessment of the quality of raw groundwater used for public water supplies within the seven study units. In the 7 study units, 462 wells were selected by using a spatially distributed, randomized grid-based method to provide statistical representation of the study area. Wells selected this way are referred to as grid wells or status wells. Approximately 3 years after the initial sampling, 55 of these previously sampled status wells (approximately 10 percent in each study unit) were randomly selected for resampling. The seven resampled study units, the total number of status wells sampled for each study unit, and the number of these wells resampled for trends are as follows, in chronological order of sampling: San Diego Drainages (53 status wells, 7 trend wells), North San Francisco Bay (84, 10), Northern San Joaquin Basin (51, 5), Southern Sacramento Valley (67, 7), San Fernando–San Gabriel (35, 6), Monterey Bay and Salinas Valley Basins (91, 11), and Southeast San Joaquin Valley (83, 9). The groundwater samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOCs], pesticides, and pesticide degradates), constituents of special interest (perchlorate, N-nitrosodimethylamine [NDMA], and 1,2,3-trichloropropane [1,2,3-TCP]), and naturally-occurring inorganic constituents (nutrients, major and minor ions, and trace elements). Naturally-occurring isotopes (tritium, carbon-14, and stable isotopes of hydrogen and oxygen in water) also were measured to help identify processes affecting groundwater quality and the sources and ages of the sampled groundwater. Nearly 300 constituents and water-quality indicators were investigated. Quality-control samples (blanks, replicates, and samples for matrix spikes) were collected at 24 percent of the 55 status wells resampled for trends, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a noticeable source of bias in the data for the groundwater samples. Differences between replicate samples were mostly within acceptable ranges, indicating acceptably low variability in analytical results. Matrix-spike recoveries were within the acceptable range (70 to 130 percent) for 75 percent of the compounds for which matrix spikes were collected. This study did not attempt to evaluate the quality of water delivered to consumers. After withdrawal, groundwater typically is treated, disinfected, and blended with other waters to maintain acceptable water quality. The benchmarks used in this report apply to treated water that is served to the consumer, not to untreated groundwater. To provide some context for the results, however, concentrations of constituents measured in these groundwater samples were compared with benchmarks established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH). Comparisons between data collected for this study and benchmarks for drinking water are for illustrative purposes only and are not indicative of compliance or non-compliance with those benchmarks. Most constituents that were detected in groundwater samples from the trend wells were found at concentrations less than drinking-water benchmarks. Four VOCs—trichloroethene, tetrachloroethene, 1,2-dibromo-3-chloropropane, and methyl tert-butyl ether—were detected in one or more wells at concentrations greater than their health-based benchmarks, and six VOCs were detected in at least 10 percent of the samples during initial sampling or resampling of the trend wells. No pesticides were detected at concentrations near or greater than their health-based benchmarks. Three pesticide constituents—atrazine, deethylatrazine, and simazine—were detected in more than 10 percent of the trend-well samples during both sampling periods. Perchlorate, a constituent of special interest, was detected more frequently, and at greater concentrations during resampling than during initial sampling, but this may be due to a change in analytical method between the sampling periods, rather than to a change in groundwater quality. Another constituent of special interest, 1,2,3-TCP, was also detected more frequently during resampling than during initial sampling, but this pattern also may not reflect a change in groundwater quality. Samples from several of the wells where 1,2,3-TCP was detected by low-concentration-level analysis during resampling were not analyzed for 1,2,3-TCP using a low-level method during initial sampling. Most detections of nutrients and trace elements in samples from trend wells were less than health-based benchmarks during both sampling periods. Exceptions include nitrate, arsenic, boron, and vanadium, all detected at concentrations greater than their health-based benchmarks in at least one well during both sampling periods, and molybdenum, detected at concentrations greater than its health-based benchmark during resampling only. The isotopic ratios of oxygen and hydrogen in water and tritium and carbon-14 activities generally changed little between sampling periods, suggesting that the predominant sources and ages of groundwater in most trend wells were consistent between the sampling periods.

  16. THE DETERMINATION OF TRACES OF IRON IN SAMPLES OF PLATINUM BY NE TRON- ACTIVATION ANALYSIS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morris, D.F.C.; Killick, R.A.

    1963-11-01

    A neutron-activation analysis method for the determination of traces of iron in samples of purified platinum is described. The nuclear reactor BEPO at Harwell was used as the neutron source. A rapid radiochemical separation procedure using carriers was employed to decontaminate the iron activity from most other induced activities. The analysis is completed by discriminated gamma scintillation counting. Results of analyses of seven samples of platinum are quoted. The method of analysis has the advantage that it obviates difficulties caused by reagent blanks or by contamination from traces of inactive iron after irradiation. Interference resulting from nuclear reactions of elementsmore » other than iron in the samples appears to be of no consequence. (auth)« less

  17. Rapid, quantitative determination of bacteria in water. [adenosine triphosphate

    NASA Technical Reports Server (NTRS)

    Chappelle, E. W.; Picciolo, G. L.; Thomas, R. R.; Jeffers, E. L.; Deming, J. W. (Inventor)

    1978-01-01

    A bioluminescent assay for ATP in water borne bacteria is made by adding nitric acid to a water sample with concentrated bacteria to rupture the bacterial cells. The sample is diluted with sterile, deionized water, then mixed with a luciferase-luciferin mixture and the resulting light output of the bioluminescent reaction is measured and correlated with bacteria present. A standard and a blank also are presented so that the light output can be correlated to bacteria in the sample and system noise can be substracted from the readings. A chemiluminescent assay for iron porphyrins in water borne bacteria is made by adding luminol reagent to a water sample with concentrated bacteria and measuring the resulting light output of the chemiluminescent reaction.

  18. Release of ethanol to the atmosphere during use of consumer cleaning products

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wooley, J.; Nazaroff, W.W.; Hodgson, A.T.

    1990-08-01

    Liquid laundry and hand dish washing detergents contain volatile organic compounds, including ethanol, that may be liberated during use and contribute to photochemical air pollution. In this study, the release of ethanol to the atmosphere during simulated household use of liquid detergents was measured. Three replicate experiments, plus a blank, were conducted in a 20-m{sup 3} environmental chamber for each of four conditions: typical dish washing (DT), high-release dish washing (DH), typical laundry (LT), and high-release laundry (LH). Average amounts of ethanol transferred to the atmosphere per use (and the fraction of ethanol used so liberated) were 32 mg (0.038)more » for DT, 100 mg (0.049) for DH, 18 mg (0.002) for LT, and 110 mg (0.011) for LH. Thus, a large fraction of the ethanol added to wash solutions with liquid detergents is discharged to the sewer rather than transferred to the atmosphere during use.« less

  19. Spices as a source of lead exposure: a market-basket survey in Sri Lanka.

    PubMed

    Senanayake, M P; Perera, R; Liyanaarachchi, L A; Dassanayake, M P

    2013-12-01

    We performed a laboratory analysis of spices sold in Sri Lanka for lead content. Samples of curry powder, chili powder and turmeric powder from seven provinces, collected using the market basket survey method, underwent atomic absorption spectrometry. Blanks and standards were utilised for instrument calibration and measurement accuracy. The results were validated in two different laboratories. All samples were found to have lead levels below the US Food and Drug Administration's action level of 0.5 μg/g. Spices sold in Sri Lanka contain lead concentrations that are low and within the stipulated safety standards.

  20. A Compact, Solid-State UV (266 nm) Laser System Capable of Burst-Mode Operation for Laser Ablation Desorption Processing

    NASA Technical Reports Server (NTRS)

    Arevalo, Ricardo, Jr.; Coyle, Barry; Paulios, Demetrios; Stysley, Paul; Feng, Steve; Getty, Stephanie; Binkerhoff, William

    2015-01-01

    Compared to wet chemistry and pyrolysis techniques, in situ laser-based methods of chemical analysis provide an ideal way to characterize precious planetary materials without requiring extensive sample processing. In particular, laser desorption and ablation techniques allow for rapid, reproducible and robust data acquisition over a wide mass range, plus: Quantitative, spatially-resolved measurements of elemental and molecular (organic and inorganic) abundances; Low analytical blanks and limits-of-detection ( ng g-1); and, the destruction of minimal quantities of sample ( g) compared to traditional solution and/or pyrolysis analyses (mg).

  1. Advanced defect classification by smart sampling, based on sub-wavelength anisotropic scatterometry

    NASA Astrophysics Data System (ADS)

    van der Walle, Peter; Kramer, Esther; Ebeling, Rob; Spruit, Helma; Alkemade, Paul; Pereira, Silvania; van der Donck, Jacques; Maas, Diederik

    2018-03-01

    We report on advanced defect classification using TNO's RapidNano particle scanner. RapidNano was originally designed for defect detection on blank substrates. In detection-mode, the RapidNano signal from nine azimuth angles is added for sensitivity. In review-mode signals from individual angles are analyzed to derive additional defect properties. We define the Fourier coefficient parameter space that is useful to study the statistical variation in defect types on a sample. By selecting defects from each defect type for further review by SEM, information on all defects can be obtained efficiently.

  2. The Combustion Experiment on the Sample Analysis at Mars (SAM) Instrument Suite on the Curiosity Rover

    NASA Technical Reports Server (NTRS)

    Stern, J. C.; Malespin, C. A.; Eigenbrode, J. L.; Graham, H. V.; Archer, P. D., Jr.; Brunner, A. E.; Freissinet, C.; Franz, H. B.; Fuentes, J.; Glavin, D. P.; hide

    2014-01-01

    The combustion experiment on the Sample Analysis at Mars (SAM) suite on Curiosity will heat a sample of Mars regolith in the presence of oxygen and measure composition of the evolved gases using quadrupole mass spectrometry (QMS) and tunable laser spectrometry (TLS). QMS will enable detection of combustion products such as CO, CO2, NO, and other oxidized species, while TLS will enable precise measurements of the abundance and carbon isotopic composition (delta(sup 13)C) of the evolved CO2 and hydrogen isotopic composition (deltaD) of H2O. SAM will perform a two-step combustion to isolate combustible materials below approx.550 C and above approx.550 C. The combustion experiment on SAM, if properly designed and executed, has the potential to answer multiple questions regarding the origins of volatiles seen thus far in SAM evolved gas analysis (EGA) on Mars. Constraints imposed by SAM and MSL time and power resources, as well as SAM consumables (oxygen gas), will limit the number of SAM combustion experiments, so it is imperative to design an experiment targeting the most pressing science questions. Low temperature combustion experiments will primarily target the quantification of carbon (and nitrogen) contributed by SAM wet chemistry reagants MTBSTFA (N-Methyl-N-tert-butyldimethylsilyltrifluoroacetamide) and DMF (Dimethylformamide), which have been identified in the background of blank and sample runs and may adsorb to the sample while the cup is in the Sample Manipulation System (SMS). In addition, differences between the sample and "blank" may yield information regarding abundance and delta(sup 13)C of bulk (both organic and inorganic) martian carbon. High temperature combustion experiments primarily aim to detect refractory organic matter, if present in Cumberland fines, as well as address the question of quantification and deltaD value of water evolution associated with hydroxyl hydrogen in clay minerals.

  3. Standardization and validation of a cytometric bead assay to assess antibodies to multiple Plasmodium falciparum recombinant antigens.

    PubMed

    Ondigo, Bartholomew N; Park, Gregory S; Gose, Severin O; Ho, Benjamin M; Ochola, Lyticia A; Ayodo, George O; Ofulla, Ayub V; John, Chandy C

    2012-12-21

    Multiplex cytometric bead assay (CBA) have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from <0.0001 - 0.004), and antibodies to variants of the same antigen were accurately distinguished within a multiplex reaction. Plasma dilutions of 1:100 or 1:200 were optimal for all antigens for CBA testing. Plasma diluted in a buffer containing 0.05% sodium azide, 0.5% polyvinylalcohol, and 0.8% polyvinylpyrrolidone had the lowest background activity. CBA median fluorescence intensity (MFI) values with 1,000 antigen-conjugated beads/well did not differ significantly from MFI with 5,000 beads/well. CBA and ELISA results correlated well for all antigens except apical membrane antigen-1 (AMA-1). CBA testing produced a greater range of values in samples from malaria endemic areas and less background reactivity for blank samples than ELISA. With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in positive samples and lower background readings for blank samples than ELISA.

  4. The study on specific umbilical blood Dc vaccine for Beige nude mice loaded human colorectal carcinoma to induce anti-tumor immunity.

    PubMed

    Fu, Z-X; Han, J-S; Liu, F; Zhao, Z-L; Li, D-B; Shi, L; Dong, J-T; Zhou, Y; Cai, J-H

    2017-05-01

    This study is to observe the immunosuppression of CD137L transfected umbilical blood Dcs (Dendritic cell) vaccine to tumor development of SCID/ Beige nude mice. Samples of umbilical blood in the childbirth pregnant women were collected by density gradient centrifugation. Umbilical cord blood dendritic cells (Dcs) were transfected by specific CD137L via LipofectamineTM method and cells were harvested. Meanwhile, the peripheral blood of volunteers was collected to isolate Dcs, the Dcs were cultured for 5 days and hatched with SW-1116 cells antigen. The mature Dcs were harvested. The male SCID/Beige nude mice were subcutaneously injected with human SW-1116 cells in axillary to build colorectal carcinoma model as blank control (Blank). The naked peripheral blood Dc vaccine group (cPBMCs), the SW-1116 antigen-specific peripheral blood Dc vaccine group (pDcs) and the CD137L specific umbilical blood Dc vaccine group (tuDcs) were injected 24 h before tumor cells injection, respectively to recur the humanized immune reconstruction. The general life, living habits changes, tumor growing time and tumor size were observed. The nude mice were sacrificed 18 days after tumor formation. The tumor size, mice weight, in vitro tumor weight, liver weight and spleen weight of mice were recorded to evaluate the anti-tumor effect of the specific immune cells. The nude mice in pDcs group showed better general living condition, slower tumor growth, smaller tumor volume and no ulceration, necrosis, and death in nude mice. The tumor formation time in different groups was 4.71 ± 0.18 ds (blank), 7.71 ± 0.29 ds (cPBMCs), 7.86 ± 0.26 ds (pDcs) and 8.14 ± 0.69 ds (tuDcs) respectively. There were significant differences between blank and other three groups (F = 40.96, p < 0.01). Compared to mice in blank group, the tumor volume of cPBMCs group was significantly smaller (201.43 ± 69.84 mm³ vs. 436.04 ± 54.50 mm³, p < 0.01) and the tumor weight were significantly smaller (1.25 ± 0.12 g vs. 2.83 ± 0.24 g, p < 0.01). The tumor volume of tuDcs mice was significantly smaller than that of blank (92.11 ± 11.55 mm³ vs. 436.04 ± 54.50 mm³, p < 0.01) and cPBMCs mice (92.11 ± 11.55 mm³ vs. 201.43 ± 69.84 mm³, p < 0.01). Similarly, the tumor weight of tuDcs mice was significantly smaller than that of blank (0.66 ± 0.07 g vs. 2.83 ± 0.24 g, p < 0.01) and cPBMCs mice (0.66 ± 0.07 g vs. 1.25 ± 0.12 g, p < 0.01). There was no significant difference in tumor volume (92.11 ± 11.55 mm³ vs. 85.61 ± 11.59 mm³, p = 0.69) and tumor weight (0.66 ± 0.07 g vs. 0.63 ± 0.09 g, p = 0.75) between tuDcs group and pDcs group. The specific CD137L transfected umbilical blood Dc vaccine had significant anti-tumor effect against human colon cancer in nude mice via increasing the number of immune effector cell in tumor microenvironment.

  5. Concentration comparison of selected constituents between groundwater samples collected within the Missouri River alluvial aquifer using purge and pump and grab-sampling methods, near the city of Independence, Missouri, 2013

    USGS Publications Warehouse

    Krempa, Heather M.

    2015-10-29

    Relative percent differences between methods were greater than 10 percent for most analyzed trace elements. Barium, cobalt, manganese, and boron had concentrations that were significantly different between sampling methods. Barium, molybdenum, boron, and uranium method concentrations indicate a close association between pump and grab samples based on bivariate plots and simple linear regressions. Grab sample concentrations were generally larger than pump concentrations for these elements and may be because of using a larger pore sized filter for grab samples. Analysis of zinc blank samples suggests zinc contamination in filtered grab samples. Variations of analyzed trace elements between pump and grab samples could reduce the ability to monitor temporal changes and potential groundwater contamination threats. The degree of precision necessary for monitoring potential groundwater threats and application objectives need to be considered when determining acceptable variation amounts.

  6. Enabling high speed friction stir welding of aluminum tailor welded blanks

    NASA Astrophysics Data System (ADS)

    Hovanski, Yuri

    Current welding technologies for production of aluminum tailor-welded blanks (TWBs) are utilized in low-volume and niche applications, and have yet to be scaled for the high-volume vehicle market. This study targeted further weight reduction, part reduction, and cost savings by enabling tailor-welded blank technology for aluminum alloys at high-volumes. While friction stir welding (FSW) has traditionally been applied at linear velocities less than one meter per minute, high volume production applications demand the process be extended to higher velocities more amenable to cost sensitive production environments. Unfortunately, weld parameters and performance developed and characterized at low to moderate welding velocities do not directly translate to high speed linear friction stir welding. Therefore, in order to facilitate production of high volume aluminum FSW components, parameters were developed with a minimum welding velocity of three meters per minute. With an emphasis on weld quality, welded blanks were evaluated for post-weld formability using a combination of numerical and experimental methods. Evaluation across scales was ultimately validated by stamping full-size production door inner panels made from dissimilar thickness aluminum tailor-welded blanks, which provided validation of the numerical and experimental analysis of laboratory scale tests.

  7. Porous mandrels provide uniform deformation in hydrostatic powder metallurgy

    NASA Technical Reports Server (NTRS)

    Gripshover, P. J.; Hanes, H. D.

    1967-01-01

    Porous copper mandrels prevent uneven deformation of beryllium machining blanks. The beryllium powder is arranged around these mandrels and hot isostatically pressed to form the blanks. The mandrels are then removed by leaching.

  8. 76 FR 37063 - Marine Mammals; File No. 16510

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-24

    ... Blank Park Zoo [Kevin V. Drees, Responsible Party], 7401 SW. Ninth, Des Moines, IA 50315, has applied in... Vancouver Aquarium, Vancouver, Canada for purposes of public display at the Blank Park Zoo. The receiving...

  9. What the Hell Do We Do Now? A Policy Options Analysis of State, Local, and Tribal Law Enforcement Participation in Immigration Enforcement

    DTIC Science & Technology

    2013-09-01

    less like adversaries and more like partners with the affected communities in the effort. 94 THIS PAGE INTENTIONALLY LEFT BLANK 95 LIST OF... INTENTIONALLY LEFT BLANK i REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704–0188 Public reporting burden for this collection of information is...ABSTRACT UU NSN 7540–01–280–5500 Standard Form 298 (Rev. 2–89) Prescribed by ANSI Std. 239–18 ii THIS PAGE INTENTIONALLY LEFT BLANK iii Approved

  10. Super-Resolution Algorithm in Cumulative Virtual Blanking

    NASA Astrophysics Data System (ADS)

    Montillet, J. P.; Meng, X.; Roberts, G. W.; Woolfson, M. S.

    2008-11-01

    The proliferation of mobile devices and the emergence of wireless location-based services have generated consumer demand for precise location. In this paper, the MUSIC super-resolution algorithm is applied to time delay estimation for positioning purposes in cellular networks. The goal is to position a Mobile Station with UMTS technology. The problem of Base-Stations herability is solved using Cumulative Virtual Blanking. A simple simulator is presented using DS-SS signal. The results show that MUSIC algorithm improves the time delay estimation in both the cases whether or not Cumulative Virtual Blanking was carried out.

  11. The impact of sampling, PCR, and sequencing replication on discerning changes in drinking water bacterial community over diurnal time-scales.

    PubMed

    Bautista-de Los Santos, Quyen Melina; Schroeder, Joanna L; Blakemore, Oliver; Moses, Jonathan; Haffey, Mark; Sloan, William; Pinto, Ameet J

    2016-03-01

    High-throughput and deep DNA sequencing, particularly amplicon sequencing, is being increasingly utilized to reveal spatial and temporal dynamics of bacterial communities in drinking water systems. Whilst the sampling and methodological biases associated with PCR and sequencing have been studied in other environments, they have not been quantified for drinking water. These biases are likely to have the greatest effect on the ability to characterize subtle spatio-temporal patterns influenced by process/environmental conditions. In such cases, intra-sample variability may swamp any underlying small, systematic variation. To evaluate this, we undertook a study with replication at multiple levels including sampling sites, sample collection, PCR amplification, and high throughput sequencing of 16S rRNA amplicons. The variability inherent to the PCR amplification and sequencing steps is significant enough to mask differences between bacterial communities from replicate samples. This was largely driven by greater variability in detection of rare bacteria (relative abundance <0.01%) across PCR/sequencing replicates as compared to replicate samples. Despite this, we captured significant changes in bacterial community over diurnal time-scales and find that the extent and pattern of diurnal changes is specific to each sampling location. Further, we find diurnal changes in bacterial community arise due to differences in the presence/absence of the low abundance bacteria and changes in the relative abundance of dominant bacteria. Finally, we show that bacterial community composition is significantly different across sampling sites for time-periods during which there are typically rapid changes in water use. This suggests hydraulic changes (driven by changes in water demand) contribute to shaping the bacterial community in bulk drinking water over diurnal time-scales. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Precise measurement of Fe isotopes in marine samples by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS).

    PubMed

    de Jong, Jeroen; Schoemann, Véronique; Tison, Jean-Louis; Becquevort, Sylvie; Masson, Florence; Lannuzel, Delphine; Petit, Jérôme; Chou, Lei; Weis, Dominique; Mattielli, Nadine

    2007-04-18

    A novel analytical technique for isotopic analysis of dissolved and particulate iron (Fe) from various marine environments is presented in this paper. It combines coprecipitation of dissolved Fe (DFe) samples with Mg(OH)(2), and acid digestion of particulate Fe (PFe) samples with double pass chromatographic separation. Isotopic data were obtained using a Nu Plasma MC-ICP-MS in dry plasma mode, applying a combination of standard-sample bracketing and external normalization by Cu doping. Argon interferences were determined prior to each analysis and automatically subtracted during analysis. Sample size can be varied between 200 and 600 ng of Fe per measurement and total procedural blanks are better than 10 ng of Fe. Typical external precision of replicate analyses (1S.D.) is +/-0.07 per thousand on delta(56)Fe and +/-0.09 per thousand on delta(57)Fe while typical internal precision of a measurement (1S.E.) is +/-0.03 per thousand on delta(56)Fe and +/-0.04 per thousand on delta(57)Fe. Accuracy and precision were assured by the analysis of reference material IRMM-014, an in-house pure Fe standard, an in-house rock standard, as well as by inter-laboratory comparison using a hematite standard from ETH (Zürich). The lowest amount of Fe (200 ng) at which a reliable isotopic measurement could still be performed corresponds to a DFe or PFe concentration of approximately 2 nmol L(-1) for a 2 L sample size. To show the versatility of the method, results are presented from contrasting environments characterized by a wide range of Fe concentrations as well as varying salt content: the Scheldt estuary, the North Sea, and Antarctic pack ice. The range of DFe and PFe concentrations encountered in this investigation falls between 2 and 2000 nmol L(-1) Fe. The distinct isotopic compositions detected in these environments cover the whole range reported in previous studies of natural Fe isotopic fractionation in the marine environment, i.e. delta(56)Fe varies between -3.5 per thousand and +1.5 per thousand. The largest fractionations were observed in environments characterized by redox changes and/or strong Fe cycling. This demonstrates the potential use of Fe isotopes as a tool to trace marine biogeochemical processes involving Fe.

  13. Support, shape and number of replicate samples for tree foliage analysis.

    PubMed

    Luyssaert, Sebastiaan; Mertens, Jan; Raitio, Hannu

    2003-06-01

    Many fundamental features of a sampling program are determined by the heterogeneity of the object under study and the settings for the error (alpha), the power (beta), the effect size (ES), the number of replicate samples, and sample support, which is a feature that is often overlooked. The number of replicates, alpha, beta, ES, and sample support are interconnected. The effect of the sample support and its shape on the required number of replicate samples was investigated by means of a resampling method. The method was applied to a simulated distribution of Cd in the crown of a Salix fragilis L. tree. Increasing the dimensions of the sample support results in a decrease in the variance of the element concentration under study. Analysis of the variance is often the foundation of statistical tests, therefore, valid statistical testing requires the use of a fixed sample support during the experiment. This requirement might be difficult to meet in time-series analyses and long-term monitoring programs. Sample supports have their largest dimension in the direction with the largest heterogeneity, i.e. the direction representing the crown height, and this will give more accurate results than supports with other shapes. Taking the relationships between the sample support and the variance of the element concentrations in tree crowns into account provides guidelines for sampling efficiency in terms of precision and costs. In terms of time, the optimal support to test whether the average Cd concentration of the crown exceeds a threshold value is 0.405 m3 (alpha = 0.05, beta = 0.20, ES = 1.0 mg kg(-1) dry mass). The average weight of this support is 23 g dry mass, and 11 replicate samples need to be taken. It should be noted that in this case the optimal support applies to Cd under conditions similar to those of the simulation, but not necessarily all the examinations for this tree species, element, and hypothesis test.

  14. Evaluation of TF11 attenuated-PSM mask blanks with DUV laser patterning

    NASA Astrophysics Data System (ADS)

    Xing, Kezhao; Björnberg, Charles; Karlsson, Henrik; Paulsson, Adisa; Beiming, Peter; Vedenpää, Jukka; Walford, Jonathan

    2008-05-01

    Tightening requirements on resolution, CD uniformity and positional accuracy push the development of improved photomask blanks. One such blank for 45nm node attenuated phase shift masks (att-PSM) provides a thinner chrome film, TF11, with a higher etch rate compared to previous generation NTAR5 att-PSM blanks from the same supplier. FEP-171, a positive chemically amplified resist, is commonly used in mask manufacturing for both e-beam and DUV laser pattern generators. TF11 chrome allows the FEP-171 resist thickness to be decreased at least down to 2000 Å while maintaining sufficient etch resistance, thereby improving photomask CD performance. The lower stress level in TF11 chrome films also reduces the image placement error induced by the material. In this study, TF11 chrome and FEP-171 resist are evaluated with exposures on a 248 nm DUV laser pattern generator, the Sigma7500. Patterning is first characterized for resist thicknesses of 2000 Å to 2600 Å in steps of 100 Å, assessing the minimum feature resolution, CD linearity, isolated-dense CD bias and dose sensitivity. Swing curve analysis shows a minimum near 2200 Å and a maximum near 2500 Å, corresponding closely to the reflectivity measurements provided by the blank supplier. The best overall patterning performance is obtained when operating near the swing maximum. The patterning performance is then studied in more detail with a resist thickness of 2550 Å that corresponds to the reflectivity maximum. This is compared to the results with 2000 Å resist, a standard thickness for e-beam exposures on TF11. The lithographic performance on NTAR5 att-PSM blanks with 3200 Å resist is also included for reference. This evaluation indicates that TF11 blanks with 2550 Å resist provide the best overall mask patterning performance obtained with the Sigma7500, showing a global CD uniformity below 4 nm (3s) and minimum feature resolution below 100 nm.

  15. Effects of Lugol staining on stenosis formation induced by radiofrequency ablation of esophageal squamous epithelium: a study in a porcine model.

    PubMed

    Schölvinck, D W; Alvarez Herrero, L; Visser, M; Bergman, J J G H M; Weusten, B L A M

    2015-10-01

    Preliminary data show higher stricture rates after radiofrequency ablation (RFA) for early esophageal squamous neoplasia compared with Barrett's esophagus. We studied the effects of Lugol stain (LS) directly prior to RFA on stricture formation in squamous epithelium. Of 16 pigs, the distal half of the esophagus was LS, followed by circumferential RFA (single application 12 J/cm(2) ) in the unstained and stained esophagus. Pigs were euthanized at day 0 (n = 4), 3 (n = 4), or 28 (n = 8). Histology was evaluated in four areas: blank-control (no RFA, no LS), blank-RFA (no LS), LS+RFA, and LS-control (no RFA). Stenosis severity in LS+RFA and blank-RFA at 28 days was assessed by the ratio of the mucosal diameter at the RFA area to the diameter 2 cm proximal of this zone. Histology showed submucosal edema in 50% of LS+RFA versus 0% in blank-RFA. Severity and depth of inflammation (day 3) was equal in LS+RFA and blank-RFA. Severity and depth of fibrosis (day 28) appeared more severe in LS+RFA. Consequently, stenosis was present in 100% (LS+RFA) versus 12.5% (blank-RFA). The stenosis-severity ratio was 0.40 (interquartile range 0.29-0.45) in LS+RFA versus 0.73 (interquartile range 0.64-0.78) in blank-RFA (P = 0.012). Limitations of this study were the difference in uptake of LS between pigs and humans, the difference in esophageal anatomy between pigs and humans, and between the proximal and distal esophagus within pigs. In conclusion, in the porcine squamous esophagus, stenosis rate and severity after RFA increased when preceded by LS. LS may be contributing in the altered response of squamous epithelium to RFA as compared with Barrett's esophagus. © 2014 International Society for Diseases of the Esophagus.

  16. Quality-Assurance Data for Routine Water Analyses by the U.S. Geological Survey Laboratory in Troy, New York - July 2005 through June 2007

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2009-01-01

    The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's Lab Master data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality control samples analyzed from July 2005 through June 2007. Results for the quality-control samples for 19 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: total aluminum, calcium, magnesium, nitrate (colorimetric method), potassium, silicon, sodium, and sulfate. Eight of the analytical procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits; these procedures were: total aluminum, calcium, dissolved organic carbon, chloride, nitrate (ion chromatograph), potassium, silicon, and sulfate. The magnesium and pH procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The acid-neutralizing capacity, total monomeric aluminum, nitrite, and specific conductance procedures were biased for the high-concentration and low-concentration samples, but were within control limits. Results from the filter-blank and analytical-blank analyses indicated that the procedures for 16 of 17 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 18 of the 21 analytes. At least 93 percent of the samples met data-quality objectives for all analytes except acid-neutralizing capacity (85 percent of samples met objectives), total monomeric aluminum (83 percent of samples met objectives), total aluminum (85 percent of samples met objectives), and chloride (85 percent of samples met objectives). The ammonium and total dissolved nitrogen did not meet the data-quality objectives. Results of the USGS interlaboratory Standard Reference Sample (SRS) Project met the Troy Laboratory data-quality objectives for 87 percent of the samples analyzed. The P-sample (low-ionic-strength constituents) analysis had two outliers each in two studies. The T-sample (trace constituents) analysis and the N-sample (nutrient constituents) analysis had one outlier each in two studies. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 85 percent of the samples met data-quality objectives for 11 of the 14 analytes; the exceptions were acid-neutralizing capacity, total aluminum and ammonium. Data-quality objectives were not met in 41 percent of samples analyzed for acid-neutralizing capacity, 50 percent of samples analyzed for total aluminum, and 44 percent of samples analyzed for ammonium. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 86 percent of the samples analyzed for calcium, magnesium, pH, potassium, and sodium. Data-quality objectives were met by 76 percent of the samples analyzed for chloride, 80 percent of the samples analyzed for specific conductance, and 77 percent of the samples analyzed for sulfate.

  17. Method and apparatus for continuously referenced analysis of reactive components in solution

    DOEpatents

    Bostick, W.D.; Denton, M.S.; Dinsmore, S.R.

    1979-07-31

    A continuously referenced apparatus for measuring the concentration of a reactive chemical species in solution comprises in combination conduit means for introducing a sample solution, means for introducing one or more reactants into a sample solution, and a stream separator disposed within the conduit means for separating the sample solution into a first sample stream and a second sample stream. A reactor is disposed in fluid communication with the first sample stream. A reaction takes place between the reactants introduced and the reactive chemical species of interest, causing the consumption or production of an indicator species in the first sample stream. Measurement means such as a photometric system are disposed in communication with the first and second sample streams, and the outputs of the measurement means are compared to provide a blanked measurement of the concentration of indicator species. The apparatus is particularly suitable for measurement of isoenzymes in body tissues or fluids.

  18. Fatalities caused by spherical bullets fired from blank cartridge guns in Istanbul, Turkey.

    PubMed

    Uzün, Ibrahim; Büyük, Yalçin; Erkol, Zerrin; Ağritmiş, Hasan; Kir, Ziya

    2009-09-01

    Blank cartridge guns are generally regarded as being harmless and are not considered to be firearms in the legal sense in most countries. To show the danger of these guns upon simple modifications, we report 59 fatalities resulting from these simply modified blank cartridge guns in Istanbul, Turkey. The great majority of the victims were males and the age of those ranged from 11 to 61 years. In 55.9% of these cases, homicide was the origin followed by suicide (39%). The right temporal region was detected to be the preferred region in suicidal shots by blank cartridge guns with a frequency of 56.5%. In trial shots, all these guns were detected to discharge steel or lead spherical objects, generally 4 or 5 mm in diameter, successfully. Our findings strongly suggest that these guns should also be considered as handguns in the legal sense.

  19. Failure Analysis of a Sheet Metal Blanking Process Based on Damage Coupling Model

    NASA Astrophysics Data System (ADS)

    Wen, Y.; Chen, Z. H.; Zang, Y.

    2013-11-01

    In this paper, a blanking process of sheet metal is studied by the methods of numerical simulation and experimental observation. The effects of varying technological parameters related to the quality of products are investigated. An elastoplastic constitutive equation accounting for isotropic ductile damage is implemented into the finite element code ABAQUS with a user-defined material subroutine UMAT. The simulations of the damage evolution and ductile fracture in a sheet metal blanking process have been carried out by the FEM. In order to guarantee computation accuracy and avoid numerical divergence during large plastic deformation, a specified remeshing technique is successively applied when severe element distortion occurs. In the simulation, the evolutions of damage at different stage of the blanking process have been evaluated and the distributions of damage obtained from simulation are in proper agreement with the experimental results.

  20. The sound insulations of studio doors. Part 1: Door blanks

    NASA Astrophysics Data System (ADS)

    Plumb, G. D.; Clark, R.

    The sound insulations of a range of different door blanks were measured. The results were compared with the sound insulations of existing BBC door blanks. The new doors were made from medium density fiberboard (MDF) which is more stable than the blockboard used in existing studio doors. Consequently, they should require less maintenance and adjustment and should have a longer lifespan. The doors had higher sound insulations for their weight than existing designs, which might permit savings in the costs of the surrounding building structures. Overall construction costs of the door blanks themselves are likely to be similar to those of existing designs. A companion Report (BBC RD 1994/15) describes sound insulation measurements made on plant-on door seals. The intention of this work was to simplify the construction of the door frame and the fitting of the seals to reduce costs.

  1. Method and apparatus for inspecting reflection masks for defects

    DOEpatents

    Bokor, Jeffrey; Lin, Yun

    2003-04-29

    An at-wavelength system for extreme ultraviolet lithography mask blank defect detection is provided. When a focused beam of wavelength 13 nm is incident on a defective region of a mask blank, three possible phenomena can occur. The defect will induce an intensity reduction in the specularly reflected beam, scatter incoming photons into an off-specular direction, and change the amplitude and phase of the electric field at the surface which can be monitored through the change in the photoemission current. The magnitude of these changes will depend on the incident beam size, and the nature, extent and size of the defect. Inspection of the mask blank is performed by scanning the mask blank with 13 nm light focused to a spot a few .mu.m in diameter, while measuring the reflected beam intensity (bright field detection), the scattered beam intensity (dark-field detection) and/or the change in the photoemission current.

  2. High Precision Low-blank Lithium Isotope Ratios in Forams.

    NASA Astrophysics Data System (ADS)

    Misra, S.; Froelich, P. N.

    2007-12-01

    We present a high precision (±1‰, 2σ) low blank (<500 fg/ml) method for Li isotope measurements of forams using <2 ng of Li by single collector Quad ICP-MS (Agilent 7500cs). The Li isotope ratio of seawater (δ7Li) recorded in planktonic forams has the potential to constrain the evolution of seawater chemistry and elucidate the factors driving variations of oceanic mass balances linked to the continental and sea floor/hydrothermal silica cycles. In addition a δ7Li record of seawater will complement other long-term recorders of seawater chemistry such as Sr, Os and S isotopes. Li isotope measurements of forams are limited by several factors: low Li concentrations in forams (1-2 ppm), instrument-induced fractionation and mass bias effects, matrix effects, high Li blanks and incomplete recovery of Li during column separation. Modest concentrations of alkali and alkaline earth elements in the matrix result in variable mass bias in measured Li isotope ratios. Even worse, Li strongly fractionates during chromatographic clean-up to remove Na+, Ca2+ and Mg2+, from +100‰ in the leading edge to - 100‰ in the trailing edge of elution peaks (Urey 1938). Consequently, miniscule incomplete recoveries of Li during chromatographic separations can result in large unrecognized isotope fractionation of eluents. Large mass-dependent fractionation caused by a difference of 17% in mass between 6Li and 7Li, makes Li a powerful tracer of geochemical processes, but also promotes large and difficult-to-fix isotope fractionations during laboratory chemical processing. Matrix effects of Na & Ca and of column chromatography on Li isotope ratios were investigated using artificial Li solutions representative of foram compositions (matrix matching). Li/Ca and Li/Na ratios in cleaned forams are 10 μmol/mol and 3 mmol/mol respectively. An ICP-MS tolerance limit of 20 ppb for Na and 20 μM for Ca was established, much higher tolerances than by TIMS. A single step chromatographic method to quantitatively separate Li from matrix elements using both small volume resin (3.4 meq/2ml AG50W-X8) and acid (6 ml of 0.5N HCl) was developed. Our low blank (<0.5 pg/ml) and high yield (>99.99%) column method minimizes errors in measured Li isotope ratios associated with incomplete column recovery and presence of matrix elements. High sensitivity and precision achieved with a 7500cs using cold plasma (600W), soft extraction and peak jumping coupled with very low sample to blank ratios enables high precision (±1‰, 2σ) statistically significant Li isotope measurements using very small mass of Li (0.8 ng). The development of this technique makes possible good quality Li isotope measurements from samples that are mass limited for Li, i.e., reasonable number of picked forams. This will enable us to test interferences regarding chemical cleaning and species effects in planktonic forams along the road toward creating a δ7Li record of seawater for the Cenozoic.

  3. The robustness and generalizability of findings on spontaneous false belief sensitivity: a replication attempt

    PubMed Central

    Priewasser, Beate; Sodian, Beate; Perner, Josef

    2018-01-01

    Influential studies showed that 25-month-olds and neurotypical adults take an agent's false belief into account in their anticipatory looking patterns (Southgate et al. 2007 Psychol. Sci. 18, 587–592 (doi:10.1111/j.1467-9280.2007.01944.x); Senju et al. 2009 Science 325, 883–885 (doi:10.1126/science.1176170)). These findings constitute central pillars of current accounts distinguishing between implicit and explicit Theory of Mind. In our first experiment, which initially included a replication as well as two manipulations, we failed to replicate the original finding in 2- to 3-year-olds (N = 48). Therefore, we ran a second experiment with the sole purpose of seeing whether the effect can be found in an independent, tightly controlled, sufficiently powered and preregistered replication study. This replication attempt failed again in a sample of 25-month-olds (N = 78), but was successful in a sample of adults (N = 115). In all samples, a surprisingly high number of participants did not correctly anticipate the agent's action during the familiarization phase. This led to massive exclusion rates when adhering to the criteria of the original studies and strongly limits the interpretability of findings from the test phase. We discuss both the reliability of our replication attempts as well as the replicability of non-verbal anticipatory looking paradigms of implicit false belief sensitivity, in general. PMID:29892412

  4. The robustness and generalizability of findings on spontaneous false belief sensitivity: a replication attempt.

    PubMed

    Schuwerk, Tobias; Priewasser, Beate; Sodian, Beate; Perner, Josef

    2018-05-01

    Influential studies showed that 25-month-olds and neurotypical adults take an agent's false belief into account in their anticipatory looking patterns (Southgate et al. 2007 Psychol. Sci. 18 , 587-592 (doi:10.1111/j.1467-9280.2007.01944.x); Senju et al. 2009 Science 325 , 883-885 (doi:10.1126/science.1176170)). These findings constitute central pillars of current accounts distinguishing between implicit and explicit Theory of Mind. In our first experiment, which initially included a replication as well as two manipulations, we failed to replicate the original finding in 2- to 3-year-olds ( N  = 48). Therefore, we ran a second experiment with the sole purpose of seeing whether the effect can be found in an independent, tightly controlled, sufficiently powered and preregistered replication study. This replication attempt failed again in a sample of 25-month-olds ( N  = 78), but was successful in a sample of adults ( N  = 115). In all samples, a surprisingly high number of participants did not correctly anticipate the agent's action during the familiarization phase. This led to massive exclusion rates when adhering to the criteria of the original studies and strongly limits the interpretability of findings from the test phase. We discuss both the reliability of our replication attempts as well as the replicability of non-verbal anticipatory looking paradigms of implicit false belief sensitivity, in general.

  5. Questa baseline and pre-mining ground-water-quality investigation. 16. Quality assurance and quality control for water analyses

    USGS Publications Warehouse

    McCleskey, R. Blaine; Nordstrom, D. Kirk; Naus, Cheryl A.

    2004-01-01

    The Questa baseline and pre-mining ground-water quality investigation has the main objective of inferring the ground-water chemistry at an active mine site. Hence, existing ground-water chemistry and its quality assurance and quality control is of crucial importance to this study and a substantial effort was spent on this activity. Analyses of seventy-two blanks demonstrated that contamination from processing, handling, and analyses were minimal. Blanks collected using water deionized with anion and cation exchange resins contained elevated concentrations of boron (0.17 milligrams per liter (mg/L)) and silica (3.90 mg/L), whereas double-distilled water did not. Boron and silica were not completely retained by the resins because they can exist as uncharged species in water. Chloride was detected in ten blanks, the highest being 3.9 mg/L, probably as the result of washing bottles, filter apparatuses, and tubing with hydrochloric acid. Sulfate was detected in seven blanks; the highest value was 3.0 mg/L, most likely because of carryover from the high sulfate waters sampled. With only a few exceptions, the remaining blank analyses were near or below method detection limits. Analyses of standard reference water samples by cold-vapor atomic fluorescence spectrometry, ion chromatography, inductively coupled plasma-optical emission spectrometry, inductively coupled plasma-mass spectrometry, FerroZine, graphite furnace atomic absorption spectrometry, hydride generation atomic spectrometry, and titration provided an accuracy check. For constituents greater than 10 times the detection limit, 95 percent of the samples had a percent error of less than 8.5. For constituents within 10 percent of the detection limit, the percent error often increased as a result of measurement imprecision. Charge imbalance was calculated using WATEQ4F and 251 out of 257 samples had a charge imbalance less than 11.8 percent. The charge imbalance for all samples ranged from -16 to 16 percent. Spike recoveries were performed by spiking ground-water samples from SC2B, SC3A, SC3B, CC2A, and Hottentot with a mixed-element standard and then analyzing them by ICP-OES. The mean recovery for all the constituents by ICP-OES was 103 percent with a standard deviation of 16 percent. Fifteen surface- and ground-water sequential duplicates were collected from Straight Creek, Hottentot, and the Red River from 2002 to 2003. Except for chloride from well SC5B and low concentrations of iron (<0.05 mg/L) and aluminum (<0.01 mg/L), constituents of sequential duplicates are generally within 10 percent of each other. Analytical results from different methods and different laboratories, with rare exceptions, were within 10 percent. Chromium analyses were in poor agreement when comparing analyses from the USGS and a contract laboratory, but USGS analyses by ICP-OES and ICP-MS were usually within 10 percent for chromium concentrations above 0.03 mg/L and analyses by ICP-OES and GFAAS were usually within 15 percent for chromium concentrations as much as 0.1 mg/L.Filtration studies also were performed to study the effects of filtration apparatuses (Minitan, plate, capsule, and syringe), pore sizes, and timing on dissolved metal concentrations. Except for iron and aluminum, constituents with concentrations greater than about 0.05 mg/L were generally not affected by the filtration apparatus, membrane pore-size, and filtration delays. Iron, aluminum, and some dissolved metals concentrations less than about 0.05 mg/L, especially copper, were generally lowest in filtrates from the tangential flow Minitan system containing a filter membrane with a pore size of 10,000 Daltons. As part of a filtration timing study, grab samples were collected from two sites along the Red River and were processed immediately and then again 1 to 3 hours later. Aluminum and iron colloids formed during the delay in the sample collected at the USGS gaging station and, after the delay, 0.1-ìm filtrate aluminum and iron concentrations approached the ultrafiltrate (Minitan) concentrations. In the upstream site below Fawn Lakes, aluminum in the 0.1-ìm filtrate decreased but did not decrease in the 0.45-ìm filtrate, signifying that the colloids formed during the delay are between 0.1 and 0.45 ìm. Dissolved nickel and pH also decreased in both samples during the delay. Except for ferrous iron and barium, a sequential filtration study 2 demonstrated that water collected from the Red River at the gage did not affect dissolved metal concentrations with increasing sample volume passing through a plate filter with 0.45- or 0.1-ìm membranes. Barium and ferrous iron both slightly decreased in the filtrate from the 0.45-ìm filter.

  6. Quality-assurance data for routine water analyses by the U.S. Geological Survey laboratory in Troy, New York - July 2003 through June 2005

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2009-01-01

    The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's Lab Master data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality control samples analyzed from July 2003 through June 2005. Results for the quality-control samples for 20 analytical procedures were evaluated for bias and precision. Control charts indicate that data for five of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, pH, silicon, and sodium. Seven of the analytical procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits; these procedures were: dissolved organic carbon, chloride, nitrate (ion chromatograph), nitrite, silicon, sodium, and sulfate. The calcium and magnesium procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The total aluminum and specific conductance procedures were biased for the high-concentration and low-concentration samples, but were within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 17 of 18 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 18 of the 22 analytes. At least 85 percent of the samples met data-quality objectives for all analytes except total monomeric aluminum (82 percent of samples met objectives), total aluminum (77 percent of samples met objectives), chloride (80 percent of samples met objectives), fluoride (76 percent of samples met objectives), and nitrate (ion chromatograph) (79 percent of samples met objectives). The ammonium and total dissolved nitrogen did not meet the data-quality objectives. Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality over the time period, with ratings for each sample in the satisfactory, good, and excellent ranges or less than 10 percent error. The P-sample (low-ionic-strength constituents) analysis had one marginal and two unsatisfactory ratings for the chloride procedure. The T-sample (trace constituents)analysis had two unsatisfactory ratings and one high range percent error for the aluminum procedure. The N-sample (nutrient constituents) analysis had one marginal rating for the nitrate procedure. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 84 percent of the samples met data-quality objectives for 11 of the 14 analytes; the exceptions were ammonium, total aluminum, and acid-neutralizing capacity. The ammonium procedure did not meet data quality objectives in all studies. Data-quality objectives were not met in 23 percent of samples analyzed for total aluminum and 45 percent of samples analyzed acid-neutralizing capacity. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 86 percent of the samples analyzed for calcium, chloride, fluoride, magnesium, pH, potassium, sodium, and sulfate. Data-quality objectives were not met by samples analyzed for fluoride. 

  7. ZERODUR 4-m blank surviving up to 20 g acceleration

    NASA Astrophysics Data System (ADS)

    Westerhoff, Thomas; Werner, Thomas; Gehindy, Thorsten

    2017-09-01

    The glass ceramic ZERODUR developed as astronomical telescope mirror substrate material has been widely used in many telescopes due to its excellent small coefficient of thermal expansion. Many large and medium sized mirror substrate blanks have been delivered in the almost 50 years of ZERODUR business so far. Packaging and transportation of mirror substrates of 4 to 8 m in diameter with a weight between 3 and 20 tons requires special attention and sophisticated skills to successful deliver the blanks to their destination at polishing shops all over the world. Typically, a combination of road and sea transport needs to be organized. The requirements on the transport container are depending on the transport route and may vary from destination to destination. In any case the container needs to be able to sufficiently support the multi ton ZERODUR blank to avoid breaking under gravity. Additionally, the configuration needs to be able to absorb shocks happening during transport and loading between truck trailer and ship. For insurance reasons the transport container is always equipped with a GPS trackable shock recorder allowing to download the recorded accelerations on the container and the blank throughout the entire journey. This paper reports on the event of a 4 m class ZERODUR blank exposed to shocks up to 20 g during transport. The event will be discussed in detail together with lessons learned to avoid such events for future transports. Additionally, the 20 g acceleration will be discussed in respect to the data on bending strength for ZERODUR ground surfaces reported in numerous papers by Peter Hartmann et.al. in the last couple of years.

  8. 2. D Street facade and rear (east) blank wall of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. D Street facade and rear (east) blank wall of parking garage. Farther east is 408 8th Street (National Art And Frame Company). - PMI Parking Garage, 403-407 Ninth Street, Northwest, Washington, District of Columbia, DC

  9. DEIsoM: a hierarchical Bayesian model for identifying differentially expressed isoforms using biological replicates

    PubMed Central

    Peng, Hao; Yang, Yifan; Zhe, Shandian; Wang, Jian; Gribskov, Michael; Qi, Yuan

    2017-01-01

    Abstract Motivation High-throughput mRNA sequencing (RNA-Seq) is a powerful tool for quantifying gene expression. Identification of transcript isoforms that are differentially expressed in different conditions, such as in patients and healthy subjects, can provide insights into the molecular basis of diseases. Current transcript quantification approaches, however, do not take advantage of the shared information in the biological replicates, potentially decreasing sensitivity and accuracy. Results We present a novel hierarchical Bayesian model called Differentially Expressed Isoform detection from Multiple biological replicates (DEIsoM) for identifying differentially expressed (DE) isoforms from multiple biological replicates representing two conditions, e.g. multiple samples from healthy and diseased subjects. DEIsoM first estimates isoform expression within each condition by (1) capturing common patterns from sample replicates while allowing individual differences, and (2) modeling the uncertainty introduced by ambiguous read mapping in each replicate. Specifically, we introduce a Dirichlet prior distribution to capture the common expression pattern of replicates from the same condition, and treat the isoform expression of individual replicates as samples from this distribution. Ambiguous read mapping is modeled as a multinomial distribution, and ambiguous reads are assigned to the most probable isoform in each replicate. Additionally, DEIsoM couples an efficient variational inference and a post-analysis method to improve the accuracy and speed of identification of DE isoforms over alternative methods. Application of DEIsoM to an hepatocellular carcinoma (HCC) dataset identifies biologically relevant DE isoforms. The relevance of these genes/isoforms to HCC are supported by principal component analysis (PCA), read coverage visualization, and the biological literature. Availability and implementation The software is available at https://github.com/hao-peng/DEIsoM Contact pengh@alumni.purdue.edu Supplementary information Supplementary data are available at Bioinformatics online. PMID:28595376

  10. Quality-Assurance Data for Routine Water Analyses by the U.S. Geological Survey Laboratory in Troy, New York - July 2001 Through June 2003

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2009-01-01

    The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's Lab Master data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality control samples analyzed from July 2001 through June 2003. Results for the quality-control samples for 19 analytical procedures were evaluated for bias and precision. Control charts indicate that data for six of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, chloride, magnesium, nitrate (ion chromatography), potassium, and sodium. The calcium procedure was biased throughout the analysis period for the high-concentration sample, but was within control limits. The total monomeric aluminum and fluoride procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The total aluminum, pH, specific conductance, and sulfate procedures were biased for the high-concentration and low-concentration samples, but were within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 16 of 18 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for the dissolved organic carbon or specific conductance procedures. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 18 of the 21 analytes. At least 90 percent of the samples met data-quality objectives for all procedures except total monomeric aluminum (83 percent of samples met objectives), total aluminum (76 percent of samples met objectives), ammonium (73 percent of samples met objectives), dissolved organic carbon (86 percent of samples met objectives), and nitrate (81 percent of samples met objectives). The data-quality objective was not met for the nitrite procedure. Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated satisfactory or above data quality over the time period, with most performance ratings for each sample in the good-to-excellent range. The N-sample (nutrient constituents) analysis had one unsatisfactory rating for the ammonium procedure in one study. The T-sample (trace constituents) analysis had one unsatisfactory rating for the magnesium procedure and one marginal rating for the potassium procedure in one study and one unsatisfactory rating for the sodium procedure in another. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 90 percent of the samples met data-quality objectives for 10 of the 14 analytes; the exceptions were acid-neutralizing capacity, ammonium, dissolved organic carbon, and sodium. Data-quality objectives were not met in 37 percent of samples analyzed for acid-neutralizing capacity, 28 percent of samples analyzed for dissolved organic carbon, and 30 percent of samples analyzed for sodium. Results indicate a positive bias for the ammonium procedure in one study and a negative bias in another. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 90 percent of the samples analyzed for calcium, chloride, magnesium, pH, potassium, and sodium. Data-quality objectives were met by 78 percent of

  11. Challenges in reproducibility of genetic association studies: lessons learned from the obesity field.

    PubMed

    Li, A; Meyre, D

    2013-04-01

    A robust replication of initial genetic association findings has proved to be difficult in human complex diseases and more specifically in the obesity field. An obvious cause of non-replication in genetic association studies is the initial report of a false positive result, which can be explained by a non-heritable phenotype, insufficient sample size, improper correction for multiple testing, population stratification, technical biases, insufficient quality control or inappropriate statistical analyses. Replication may, however, be challenging even when the original study describes a true positive association. The reasons include underpowered replication samples, gene × gene, gene × environment interactions, genetic and phenotypic heterogeneity and subjective interpretation of data. In this review, we address classic pitfalls in genetic association studies and provide guidelines for proper discovery and replication genetic association studies with a specific focus on obesity.

  12. Observations of the atmosphere and surface state over Terra Nova Bay, Antarctica using unmanned aircraft systems

    NASA Astrophysics Data System (ADS)

    Cassano, J. J.; Seefeldt, M. W.; Palo, S.; Knuth, S. L.; Bradley, A. C.; Herrman, P. D.; Kernebone, P. A.; Logan, N. J.

    2015-12-01

    In September 2012 five Aerosonde unmanned aircraft were used to make measurements of the atmospheric state over the Terra Nova Bay polynya, Antarctica, to explore the details of air - sea ice - ocean coupling. A total of 14 flights were completed in September 2012. Ten of the flight missions consisted of two unmanned aircraft systems (UAS) sampling the atmosphere over Terra Nova Bay on five different days, with one UAS focusing on the downwind evolution of the air mass and a second UAS flying transects roughly perpendicular to the low level winds. The data from these coordinated UAS flights provide a comprehensive three-dimensional data set of the atmospheric state (air temperature, humidity, pressure, and wind) and surface skin temperature over Terra Nova Bay. The remaining UAS flights during the September 2012 field campaign included two local flights near McMurdo Station for flight testing, a single UAS flight to Terra Nova Bay, and a single UAS flight over the Ross Ice Shelf and Ross Sea polynya. A dataset containing the atmospheric and surface data as well as operational aircraft data has been submitted to the United States Antarctic Program Data Coordination Center (USAP-DCC, http://www.usap-data.org/) for free access (http://gcmd.nasa.gov/getdif.htm?NSF-ANT10-43657, doi:10.15784/600125).

  13. Evolution of microbial communities during electrokinetic treatment of antibiotic-polluted soil.

    PubMed

    Li, Hongna; Li, Binxu; Zhang, Zhiguo; Zhu, Changxiong; Tian, Yunlong; Ye, Jing

    2018-02-01

    The evolution of microbial communities during the electrokinetic treatment of antibiotic-polluted soil (EKA) was investigated with chlortetracycline (CTC), oxytetracycline (OTC) and tetracycline (TC) as template antibiotics. The total population of soil microorganisms was less affected during the electrokinetic process, while living anti-CTC, anti-OTC, anti-TC and anti-MIX bacteria were inactivated by 10.48%, 31.37%, 34.76%, and 22.08%, respectively, during the 7-day treatment compared with antibiotic-polluted soil without an electric field (NOE). Accordingly, samples with NOE treatment showed a higher Shannon index than those with EKA treatment, indicating a reduction of the microbial community diversity after electrokinetic processes. The major taxonomic phyla found in the samples of EKA and NOE treatment were Proteobacteria, Bacteroidetes, Firmicutes and Actinobacteria. And the distribution of Actinobacteria, Cyanobacteria, and Chloroflexi was greatly decreased compared with blank soil. In the phylum Proteobacteria, the abundance of Alphaproteobacteria was greatly reduced in the soils supplemented with antibiotics (from 13.40% in blank soil to 6.43-10.16% after treatment); while Betaproteobacteria and Deltaproteobacteria showed a different trend with their abundance increased compared to blank soil, and Gammaproteobacteria remained unchanged for all treatments (2.36-2.78%). The varied trends for different classes indicated that the major bacterial groups changed with the treatments due to their different adaptability to the antibiotics as well as to the electric field. SulI being an exception, the reduction ratio of the observed antibiotic resistance genes (ARGs) including tetC, tetG, tetW, tetM, intI1, and sulII in the 0-2cm soil sampled with EKA versus NOE treatment reached 55.17%, 3.59%, 99.26%, 89.51%, 30.40%, and 27.92%, respectively. Finally, correlation analysis was conducted between antibiotic-resistant bacteria, ARGs and taxonomic bacterial classes. It was found that sulII was the most representative of many different bacteria among the seven ARGs studied. This is the first report on the changes in microbial communities before and after EKA, and the present results demonstrated that the application of EKA is a useful and effective approach to suppressing both antibiotic resistant microorganisms and ARGs. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. 77 FR 6584 - Specialty Bar Products Company,a Subsidiary of Doncasters, Inc., Blairsville, PA; Notice of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-08

    ... gun blanks. The initial investigation resulted in a negative determination based on the findings that the subject firm did not shift the production of pins, bushings, gun blanks (or like or directly...

  15. Detection of human parvovirus 4 viremia in the follow-up blood samples from seropositive individuals suggests the existence of persistent viral replication or reactivation of latent viral infection.

    PubMed

    Chen, Mao-Yuan; Hung, Chien-Ching; Lee, Kuang-Lun

    2015-06-19

    The transmission routes for human parvovirus 4 (PARV4) infections in areas with high seroprevalence are not known. In the work described here, persistent PARV4 viral replication was investigated by conducting a longitudinal study. Ten healthcare workers each provided a blood sample at the beginning of the study (first sample) and 12 months later (second sample). The paired samples were tested for PARV4-positivity by immunoblotting analysis and nested polymerase chain reactions. IgG antibodies against PARV4 were detected in six participants, three of whom also had IgM antibodies against PARV4. The immunoblotting results did not vary over time. PARV4 DNA was detected in the first blood sample from one participant who had IgG antibodies against PARV4 and in the second blood samples from 2 participants who had IgG and IgM antibodies against PARV4. Detection of PARV4 DNA in the second blood samples from two seropositive participants suggests the existence of persistent PARV4 replication or reactivation of inactive virus in the tissues. The finding of persistent or intermittent PARV4 replication in individuals with past infections provides an important clue toward unraveling the non-parenteral transmission routes of PARV4 infection in areas where the virus is endemic.

  16. Modeling of the minimum variable blank holder force based on forming limit diagram (FLD) in deep drawing process

    NASA Astrophysics Data System (ADS)

    Candra, S.; Batan, I. M. L.; Berata, W.; Pramono, A. S.

    2017-11-01

    This paper presents the mathematical approach of minimum blank holder force to prevent wrinkling in deep drawing process of the cylindrical cup. Based on the maximum of minor-major strain ratio, the slab method was applied to determine the modeling of minimum variable blank holder force (VBHF) and it compared to FE simulation. The Tin steel sheet of T4-CA grade, with the thickness of 0.2 mm was used in this study. The modeling of minimum VBHF can be used as a simple reference to prevent wrinkling in deep drawing.

  17. Numerical investigation of effects on blanks for press hardening process during longitudinal flux heating

    NASA Astrophysics Data System (ADS)

    Dietrich, André; Nacke, Bernard

    2018-05-01

    With the induction heating technology, it is possible to heat up blanks for the press hardening process in 20 s or less. Furthermore, the dimension of an induction system is small and easy to control in comparison to conventional heating systems. To bring the induction heating technology to warm forming industry it is necessary to analyze the process under the view of induction. This paper investigates the edge- and end-effects of a batch heated blank. The results facilitate the later design of induction heating systems for the batch process.

  18. Closed-Loop Control of Myoelectric Prostheses With Electrotactile Feedback: Influence of Stimulation Artifact and Blanking.

    PubMed

    Hartmann, Cornelia; Dosen, Strahinja; Amsuess, Sebastian; Farina, Dario

    2015-09-01

    Electrocutaneous stimulation is a promising approach to provide sensory feedback to amputees, and thus close the loop in upper limb prosthetic systems. However, the stimulation introduces artifacts in the recorded electromyographic (EMG) signals, which may be detrimental for the control of myoelectric prostheses. In this study, artifact blanking with three data segmentation approaches was investigated as a simple method to restore the performance of pattern recognition in prosthesis control (eight motions) when EMG signals are corrupted by stimulation artifacts. The methods were tested over a range of stimulation conditions and using four feature sets, comprising both time and frequency domain features. The results demonstrated that when stimulation artifacts were present, the classification performance improved with blanking in all tested conditions. In some cases, the classification performance with blanking was at the level of the benchmark (artifact-free data). The greatest pulse duration and frequency that allowed a full performance recovery were 400 μs and 150 Hz, respectively. These results show that artifact blanking can be used as a practical solution to eliminate the negative influence of the stimulation artifact on EMG pattern classification in a broad range of conditions, thus allowing to close the loop in myoelectric prostheses using electrotactile feedback.

  19. Design of Channel Type Indirect Blank Holder for Prevention of Wrinkling and Fracture in Hot Stamping Process

    NASA Astrophysics Data System (ADS)

    Choi, Hong-seok; Ha, Se-yoon; Cha, Seung-hoon; kang, Chung-gil; Kim, Byung-min

    2011-08-01

    The hot stamping process has been used in the automotive industry to reduce the weight of the body-in-white and to increase passenger safety via improved crashworthiness. In this study, a new form die with a simple structure that can prevent defects such as wrinkle and fracture is proposed for the manufacture of hot stamped components. The wrinkling at the flange cannot be eliminated when using a conventional form die. It is known that the initiation of wrinkling is influenced by many factors such as the mechanical properties of the sheet material, geometry of the sheet and tool, and other process parameters, including the blank holding force (BHF) and the contact conditions. In this research, channel type indirect blank holder (CIBH) is introduced to replace general blank holder for manufacturing the hot stamped center pillar. First, we investigate the tension force acting on the blank according to the channel shapes. We determine the appropriate range by comparing the tension force with the upper and lower BHFs in a conventional stamping process. We then use FE-analysis to study the influence of the slope angle and corner radius of the channel on the formability. Finally, the center pillar is manufactured using the form die with the selected channel.

  20. Magnetron sputtering for the production of EUV mask blanks

    NASA Astrophysics Data System (ADS)

    Kearney, Patrick; Ngai, Tat; Karumuri, Anil; Yum, Jung; Lee, Hojune; Gilmer, David; Vo, Tuan; Goodwin, Frank

    2015-03-01

    Ion Beam Deposition (IBD) has been the primary technique used to deposit EUV mask blanks since 1995 when it was discovered it could produce multilayers with few defects. Since that time the IBD technique has been extensively studied and improved and is finally approaching usable defectivities. But in the intervening years, the defectivity of magnetron sputtering has been greatly improved. This paper evaluates the suitability of a modern magnetron tool to produce EUV mask blanks and the ability to support HVM production. In particular we show that the reflectivity and uniformity of these tools are superior to current generation IBD tools, and that the magnetron tools can produce EUV films with defect densities comparable to recent best IBD tool performance. Magnetron tools also offer many advantages in manufacturability and tool throughput; however, challenges remain, including transitioning the magnetron tools from the wafer to mask formats. While work continues on quantifying the capability of magnetron sputtering to meet the mask blank demands of the industry, for the most part the remaining challenges do not require any fundamental improvements to existing technology. Based on the recent results and the data presented in this paper there is a clear indication that magnetron deposition should be considered for the future of EUV mask blank production.

  1. Evaluation of the memory effect on gold-coated silica adsorption tubes used for the analysis of gaseous mercury by cold vapor atomic absorption spectrometry.

    PubMed

    Rahman, Mohammad Mahmudur; Brown, Richard J C; Kim, Ki-Hyun; Yoon, Hye-On; Phan, Nhu-Thuc

    2013-01-01

    In an effort to reduce the experimental bias involved in the analysis of gaseous elemental mercury (Hg(o)), the blank response from gold-coated adsorption tubes has been investigated using cold vapor atomic absorption spectrometry (CVAAS). Our study has been compared with our recent investigation on memory effect in a cold vapour atomic fluorescence spectrometry (CVAFS). The pattern of blank responses was quantified after loading different amounts of mercury and after different time intervals of 1, 14, and 45 days. In case of the one day interval, the result of five to six instant blank heating cycles confirmed successful liberation of mercury following the second and third blank heating cycles. The results of 14 or 45 days generally suggest that liberation of excess mercury is affected by both the initial loading amount and the length of storage time prior to analysis. We have demonstrated a possibly effective way to reduce memory effects. Some similarities of these results with those from CVAFS experiment suggests that the blank response is caused by a combination of mercury absorbed within the bulk gold and micro- and nanoparticles liberated during heating and not from coabsorbing interfering gaseous species.

  2. Evaluation of the Memory Effect on Gold-Coated Silica Adsorption Tubes Used for the Analysis of Gaseous Mercury by Cold Vapor Atomic Absorption Spectrometry

    PubMed Central

    Rahman, Mohammad Mahmudur; Brown, Richard J. C.; Yoon, Hye-On; Phan, Nhu-Thuc

    2013-01-01

    In an effort to reduce the experimental bias involved in the analysis of gaseous elemental mercury (Hgo), the blank response from gold-coated adsorption tubes has been investigated using cold vapor atomic absorption spectrometry (CVAAS). Our study has been compared with our recent investigation on memory effect in a cold vapour atomic fluorescence spectrometry (CVAFS). The pattern of blank responses was quantified after loading different amounts of mercury and after different time intervals of 1, 14, and 45 days. In case of the one day interval, the result of five to six instant blank heating cycles confirmed successful liberation of mercury following the second and third blank heating cycles. The results of 14 or 45 days generally suggest that liberation of excess mercury is affected by both the initial loading amount and the length of storage time prior to analysis. We have demonstrated a possibly effective way to reduce memory effects. Some similarities of these results with those from CVAFS experiment suggests that the blank response is caused by a combination of mercury absorbed within the bulk gold and micro- and nanoparticles liberated during heating and not from coabsorbing interfering gaseous species. PMID:23589708

  3. Influence of prepreg characteristics on stamp consolidation

    NASA Astrophysics Data System (ADS)

    Slange, T. K.; Warnet, L. L.; Grouve, W. J. B.; Akkerman, R.

    2017-10-01

    Stamp forming is a rapid manufacturing technology used to shape flat blanks of thermoplastic composite material into three-dimensional components. The development of automated lay-up technologies further extends the applicability of stamp forming by allowing rapid lay-up of tailored blanks and partial preconsolidation. This partial preconsolidation makes the influence of prepreg more critical compared to conventional preconsolidation methods which provide full preconsolidation. This paper aims to highlight consolidation challenges that can appear when stamp forming blanks manufactured by automated lay-up. Important prepreg characteristics were identified based on an experimental study where a comparison was made between various prepreg in their as-received, deconsolidated and stamp consolidated state. It was found that adding up small thickness variations across the width of a prepreg when stacking plies into a blank by automated lay-up can cause non-uniform consolidation. Additionally, deconsolidation of the prepreg does not seem to obstruct interlaminar bonding, while intralaminar voids initially present in a prepreg cannot be removed during stamp forming. An additional preconsolidation step after automated lay-up seems necessary to remove blank thickness variations and intralaminar voids for the current prepregs. Eliminating this process step and the successful combination of rapid automated lay-up and stamp forming requires prepregs which are void-free and have less thickness variation.

  4. Development of Methods and Equipment for Sheet Stamping

    NASA Astrophysics Data System (ADS)

    Botashev, A. Yu; Bisilov, N. U.; Malsugenov, R. S.

    2018-03-01

    New methods of sheet stamping were developed: the gas forming with double-sided heating of a blank part and the gas molding with backpressure. In case of the first method the blank part is heated to the set temperature by means of a double-sided impact of combustion products of gas mixtures, after which, under the influence of gas pressure a stamping process is performed. In case of gas molding with backpressure, the blank part is heated to the set temperature by one-sided impact of the combustion products, while backpressure is created on the opposite side of the blank part by compressed air. In both methods the deformation takes place in the temperature range of warm or hot treatment due to the heating of a blank part. This allows one to form parts of complicated shape within one technological operation, which significantly reduces the cost of production. To implement these methods, original devices were designed and produced, which are new types of forging and stamping equipment. Using these devices, an experimental research on the stamping process was carried out and high-quality parts were obtained, which makes it possible to recommend the developed methods of stamping in the industrial production. Their application in small-scale production will allow one to reduce the cost price of stamped parts 2 or 3 times.

  5. Origins of DNA Replication and Amplification in the Breast Cancer Genome

    DTIC Science & Technology

    2011-09-01

    AD_________________ Award Number: W81XWH-10-1-0463 TITLE: Origins of DNA Replication and...hypothesis we need to map origins of DNA replication in the genome and ask which of these coincide with sites of DNA amplification and with ER...Spring Harbor DNA Replication meetings this summer/earlyfall. Figures from the posters and also the abstracts are attached. The samples have been

  6. Installation Restoration Program. Phase II. Confirmation/Quantification. Stage 1. Volume 2. Appendix J-M.

    DTIC Science & Technology

    1985-06-28

    1984 to April 1985 includedr installation of 27 raw mnitor wells and 11 amh l’,(1 zjit~s, collecticn cf seive~t, sarples ftw surfac , soil, shallowv...modifying a sampling and analytical program that addresses the requirements of the project. If project requirements necessitate different quality...reagent blank and at least five (5) different concentrations of thl analyte. A modification of the method of Hubaux and Vos will be used to deter

  7. DMSP Special Sensor Microwave/Imager Calibration/Validation. Volume 1

    DTIC Science & Technology

    1990-01-01

    each channel samples the hot load on every scan and commands a gain change up when the hot load is below 7/16th of the analog to digital converter range...OLS imagery. A threshold blanking technique was used to convert the manual analyses into synthetic digital images containing the cloud truth...should include OLS digital thermal infrared into the analysis. While this will be of use only in clear, relatively dry atmospheric conditions, the

  8. Quantitative trace analysis of polyfluorinated alkyl substances (PFAS) in ambient air samples from Mace Head (Ireland): A method intercomparison

    NASA Astrophysics Data System (ADS)

    Jahnke, Annika; Barber, Jonathan L.; Jones, Kevin C.; Temme, Christian

    A method intercomparison study of analytical methods for the determination of neutral, volatile polyfluorinated alkyl substances (PFAS) was carried out in March, 2006. Environmental air samples were collected in triplicate at the European background site Mace Head on the west coast of Ireland, a site dominated by 'clean' westerly winds coming across the Atlantic. Extraction and analysis were performed at two laboratories active in PFAS research using their in-house methods. Airborne polyfluorinated telomer alcohols (FTOHs), fluorooctane sulfonamides and sulfonamidoethanols (FOSAs/FOSEs) as well as additional polyfluorinated compounds were investigated. Different native and isotope-labelled internal standards (IS) were applied at various steps in the analytical procedure to evaluate the different quantification strategies. Field blanks revealed no major blank problems. European background concentrations observed at Mace Head were found to be in a similar range to Arctic data reported in the literature. Due to trace-levels at the remote site, only FTOH data sets were complete and could therefore be compared between the laboratories. Additionally, FOSEs could partly be included. Data comparison revealed that despite the challenges inherent in analysis of airborne PFAS and the low concentrations, all methods applied in this study obtained similar results. However, application of isotope-labelled IS early in the analytical procedure leads to more precise results and is therefore recommended.

  9. Reappraisal of hydrocarbon biomarkers in Archean rocks

    PubMed Central

    French, Katherine L.; Hallmann, Christian; Hope, Janet M.; Schoon, Petra L.; Zumberge, J. Alex; Hoshino, Yosuke; Peters, Carl A.; George, Simon C.; Love, Gordon D.; Brocks, Jochen J.; Buick, Roger; Summons, Roger E.

    2015-01-01

    Hopanes and steranes found in Archean rocks have been presented as key evidence supporting the early rise of oxygenic photosynthesis and eukaryotes, but the syngeneity of these hydrocarbon biomarkers is controversial. To resolve this debate, we performed a multilaboratory study of new cores from the Pilbara Craton, Australia, that were drilled and sampled using unprecedented hydrocarbon-clean protocols. Hopanes and steranes in rock extracts and hydropyrolysates from these new cores were typically at or below our femtogram detection limit, but when they were detectable, they had total hopane (<37.9 pg per gram of rock) and total sterane (<32.9 pg per gram of rock) concentrations comparable to those measured in blanks and negative control samples. In contrast, hopanes and steranes measured in the exteriors of conventionally drilled and curated rocks of stratigraphic equivalence reach concentrations of 389.5 pg per gram of rock and 1,039 pg per gram of rock, respectively. Polycyclic aromatic hydrocarbons and diamondoids, which exceed blank concentrations, exhibit individual concentrations up to 80 ng per gram of rock in rock extracts and up to 1,000 ng per gram of rock in hydropyrolysates from the ultraclean cores. These results demonstrate that previously studied Archean samples host mixtures of biomarker contaminants and indigenous overmature hydrocarbons. Therefore, existing lipid biomarker evidence cannot be invoked to support the emergence of oxygenic photosynthesis and eukaryotes by ∼2.7 billion years ago. Although suitable Proterozoic rocks exist, no currently known Archean strata lie within the appropriate thermal maturity window for syngenetic hydrocarbon biomarker preservation, so future exploration for Archean biomarkers should screen for rocks with milder thermal histories. PMID:25918387

  10. The EPIC-MOS Particle-Induced Background Spectra

    NASA Technical Reports Server (NTRS)

    Kuntz, K. D.; Sowden, S. L.

    2007-01-01

    In order to analyse diffuse emission that fills the field of view, one must accurately characterize the instrumental backgrounds. For the XMM-Newton EPIC instrument these backgrounds include a temporally variable "quiescent" component. as well as the strongly variable soft proton contamination. We have characterized the spectral and spatial response of the EPIC detectors to these background components and have developed tools to remove these backgrounds from observations. The "quiescent" component was characterized using a combination of the filter-wheel-closed data and a database of unexposed-region data. The soft proton contamination was characterized by differencing images and spectra taken during flared and flare-free intervals. After application of our modeled backgrounds, the differences between independent observations of the same region of "blank sky" are consistent with the statistical uncertainties except when there is clear spectral evidence of solar wind charge exchange emission. Using a large sample of blank sky data, we show that strong magnetospheric SWCX emission requires elevated solar wind fluxes; observations through the densest part of the magnetosheath are not necessarily strongly contaminated with SWCX emission.

  11. Introduction of anticoagulation group to polypropylene film by radiation grafting and its blood compatibility

    NASA Astrophysics Data System (ADS)

    Mao, Chun; Zhang, Can; Qiu, Yongzhi; Zhu, Aiping; Shen, Jian; Lin, Sicong

    2004-04-01

    Based on in vitro tests for an improvement of the blood compatibility of polypropylene (PP) films by grafting O-butyrylchitosan (OBCS), we prepared a novel biocompatible film. The immobilization was accomplished by irradiating with ultraviolet light, OBCS being coated on the film surface to photolyze azide groups, thus cross-linking OBCS and PP together. The grafted sample films were verified by attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR), electron spectroscopy for chemical analysis (ESCA) and the water contact angle measurements. The blood compatibility of the OBCS-grafted PP films was evaluated by platelet rich plasma (PRP) contacting experiments and protein adsorption experiments using blank PP film as the control. It demonstrated that blood compatibility of the OBCS-grafted surfaces is better than that of the blank PP. The suitable modifications could be carried out to tailor PP biomaterial to meet the specific needs of different biomedical applications. These results suggest that the photocrosslinkable chitosan developed here has the potential of serving as a new biomaterial in medical use.

  12. Delineating the Construct Network of the Personnel Reaction Blank: Associations with Externalizing Tendencies and Normal Personality

    PubMed Central

    Blonigen, Daniel M.; Patrick, Christopher J.; Gasperi, Marianna; Steffen, Benjamin; Ones, Deniz S.; Arvey, Richard D.; de Oliveira Baumgartl, Viviane; do Nascimento, Elizabeth

    2010-01-01

    Integrity testing has long been utilized in personnel selection to screen for tendencies toward counterproductive workplace behaviors. The construct of externalizing from the psychopathology literature represents a coherent spectrum marked by disinhibitory traits and behaviors. The present study used a sample of male and female undergraduates to examine the construct network of the Personnel Reaction Blank (PRB; Gough, Arvey, & Bradley, 2004), a measure of integrity, in relation to externalizing as well as normal-range personality constructs assessed by the Multidimensional Personality Questionnaire (MPQ; Tellegen & Waller, 2008). Results revealed moderate to strong associations between several PRB scales and externalizing, which were largely accounted for by MPQ traits subsumed by Negative Emotionality and Constraint. After accounting for MPQ traits in the prediction of externalizing, a modest predictive increment was achieved when adding the PRB scales, particularly biographical indicators from the Prosocial Background subscale. The findings highlight externalizing as a focal criterion for scale development in the integrity testing literature, and help delineate the construct network of the PRB within the domains of personality and psychopathology. PMID:21171783

  13. A replication of a factor analysis of motivations for trapping

    USGS Publications Warehouse

    Schroeder, Susan; Fulton, David C.

    2015-01-01

    Using a 2013 sample of Minnesota trappers, we employed confirmatory factor analysis to replicate an exploratory factor analysis of trapping motivations conducted by Daigle, Muth, Zwick, and Glass (1998).  We employed the same 25 items used by Daigle et al. and tested the same five-factor structure using a recent sample of Minnesota trappers. We also compared motivations in our sample to those reported by Daigle et el.

  14. A Tumor-stroma Targeted Oncolytic Adenovirus Replicated in Human Ovary Cancer Samples and Inhibited Growth of Disseminated Solid Tumors in Mice

    PubMed Central

    Lopez, M Veronica; Rivera, Angel A; Viale, Diego L; Benedetti, Lorena; Cuneo, Nicasio; Kimball, Kristopher J; Wang, Minghui; Douglas, Joanne T; Zhu, Zeng B; Bravo, Alicia I; Gidekel, Manuel; Alvarez, Ronald D; Curiel, David T; Podhajcer, Osvaldo L

    2012-01-01

    Targeting the tumor stroma in addition to the malignant cell compartment is of paramount importance to achieve complete tumor regression. In this work, we modified a previously designed tumor stroma-targeted conditionally replicative adenovirus (CRAd) based on the SPARC promoter by introducing a mutated E1A unable to bind pRB and pseudotyped with a chimeric Ad5/3 fiber (Ad F512v1), and assessed its replication/lytic capacity in ovary cancer in vitro and in vivo. AdF512v1 was able to replicate in fresh samples obtained from patients: (i) with primary human ovary cancer; (ii) that underwent neoadjuvant treatment; (iii) with metastatic disease. In addition, we show that four intraperitoneal (i.p.) injections of 5 × 1010 v.p. eliminated 50% of xenografted human ovary tumors disseminated in nude mice. Moreover, AdF512v1 replication in tumor models was enhanced 15–40-fold when the tumor contained a mix of malignant and SPARC-expressing stromal cells (fibroblasts and endothelial cells). Contrary to the wild-type virus, AdF512v1 was unable to replicate in normal human ovary samples while the wild-type virus can replicate. This study provides evidence on the lytic capacity of this CRAd and highlights the importance of targeting the stromal tissue in addition to the malignant cell compartment to achieve tumor regression. PMID:22948673

  15. Chemical analysis of aerosol in the Venusian cloud layer by reaction gas chromatography on board the Vega landers

    NASA Technical Reports Server (NTRS)

    Gelman, B. G.; Drozdov, Y. V.; Melnikov, V. V.; Rotin, V. A.; Khokhlov, V. N.; Bondarev, V. B.; Dolnikov, G. G.; Dyachkov, A. V.; Nenarokov, D. F.; Mukhin, L. M.

    1986-01-01

    The experiment on sulfuric acid aerosol determination in the Venusian cloud layer on board the Vega landers is described. An average content of sulfuric acid of approximately 1 mg/cu m was found for the samples taken from the atmosphere at heights from 63 to 48 km and analyzed with the SIGMA-3 chromatograph. Sulfur dioxide (SO2) was revealed in the gaseous sample at the height of 48 km. From the experimental results and blank run measurements, a suggestion is made that the Venusian cloud layer aerosol consists of more complicated particles than the sulfuric acid water solution does.

  16. Surface and catalytic properties of acid metal carbons prepared by the sol gel method

    NASA Astrophysics Data System (ADS)

    Aguado-Serrano, J.; Rojas-Cervantes, M. L.; Martín-Aranda, R. M.; López-Peinado, A. J.; Gómez-Serrano, V.

    2006-06-01

    The sol-gel method has been applied for the synthesis of a series of acid metal-carbon xerogels (with M = V, Cr, Mo and Ni) by polymerisation of resorcinol with formaldehyde in the presence of metallic precursors. A blank sample was also prepared without any metal addition. The xerogels were heated in nitrogen at 1000 °C to obtain the pyrolysed products. The samples were characterised by different techniques such as thermal-mass spectrometry analysis, gas physisorption, and mercury porosimetry. In addition, the acid character of the pyrolysed products was tested by the Claisen-Schmidt condensation between benzaldehyde and acetophenone for the formation of chalcones.

  17. Application of microwave digestion to the analysis of peat

    USGS Publications Warehouse

    Papp, C.S.E.; Fischer, L.B.

    1987-01-01

    A microwave digestion technique for the dissolution of peat is described and compared with a dry ashing method and a nitric - perchloric - hydrofluoric acid wet digestion. Peat samples with different organic matter contents were used and Ca, Mg, Fe, AI, Na, K, Mn, Zn, Cu and Li were determined by atomic absoprtion spectrometry. The results obtained using the three dissolution techniques were in good agreement. The microwave method has the advantage of digesting the samples in less than 2 h and uses less acid than the conventional wet digestion method. Keeping the volume of the acid mixture as small as possible minimises contamination and leads to lower blank values.

  18. Effects of Post-Weld Heat Treatment on the Mechanical Properties of Similar- and Dissimilar-Alloy Friction Stir Welded Blanks

    NASA Astrophysics Data System (ADS)

    Zadpoor, Amir Abbas; Sinke, Jos

    2011-01-01

    Friction stir welding is a solid state joining process with relatively low welding temperatures. Nevertheless, the mechanical properties of friction stir welded blanks are degraded after welding. Indeed, both strength and ductility of the welds are decreased after welding. Often, the resulting friction stir welded blanks need to be formed to their final structural shape. Therefore, the formability of friction stir welded blanks is of primary importance in the manufacturing of structural parts. This paper studies how the mechanical properties and particularly formability of friction stir welded blanks can be improved by applying a post weld heat treatment. Two aluminum alloys from 2000 and 7000 series, namely 2024-T3 and 7075-T6, are selected for the study. The sheet thickness of both materials is 2,0 mm. The selected alloys are welded in three configurations: 2024-T3 and 2024-T3, 7075-T6 and 7075-T6, and 2024-T3 and 7075-T6. The resulting welds are naturally aged for a few months. Three sets of standard dog bone shape tensile test specimens are then machined from the welds. The first set of the specimens is tested without any heat treatment. The second set of the specimens is solution heat treated and quenched before testing. The third set of the specimens is solution heat treated, quenched, and naturally aged for a week before testing. The mechanical properties of the three different sets of specimens are compared with each other. It is shown that careful selection of post weld heat-treatment can greatly improve the formability of friction stir welded blanks.

  19. Setup of a Parameterized FE Model for the Die Roll Prediction in Fine Blanking using Artificial Neural Networks

    NASA Astrophysics Data System (ADS)

    Stanke, J.; Trauth, D.; Feuerhack, A.; Klocke, F.

    2017-09-01

    Die roll is a morphological feature of fine blanked sheared edges. The die roll reduces the functional part of the sheared edge. To compensate for the die roll thicker sheet metal strips and secondary machining must be used. However, in order to avoid this, the influence of various fine blanking process parameters on the die roll has been experimentally and numerically studied, but there is still a lack of knowledge on the effects of some factors and especially factor interactions on the die roll. Recent changes in the field of artificial intelligence motivate the hybrid use of the finite element method and artificial neural networks to account for these non-considered parameters. Therefore, a set of simulations using a validated finite element model of fine blanking is firstly used to train an artificial neural network. Then the artificial neural network is trained with thousands of experimental trials. Thus, the objective of this contribution is to develop an artificial neural network that reliably predicts the die roll. Therefore, in this contribution, the setup of a fully parameterized 2D FE model is presented that will be used for batch training of an artificial neural network. The FE model enables an automatic variation of the edge radii of blank punch and die plate, the counter and blank holder force, the sheet metal thickness and part diameter, V-ring height and position, cutting velocity as well as material parameters covered by the Hensel-Spittel model for 16MnCr5 (1.7131, AISI/SAE 5115). The FE model is validated using experimental trails. The results of this contribution is a FE model suitable to perform 9.623 simulations and to pass the simulated die roll width and height automatically to an artificial neural network.

  20. Effects of process variation in short cycle stretch forming in beverage can production

    NASA Astrophysics Data System (ADS)

    Schneider, Matthias; Liewald, Mathias

    2016-10-01

    Short Cycle Stretch Forming (SCS) is an innovative stretch forming technology developed at the Institute for Metal Forming Technology (IFU) at the University of Stuttgart. The SCS technology combines plane pre-stretching and deep drawing operations within the same stroke of press ram. Material is yielding from the inner to the outer part of the sheet. The sheet thickness is reduced and denting resistance and yield stress are increased due to hardening effects. SCS-Technology is enhanced due to rotational-symmetrical bodies by applying this technology to a cupping process in tinplate can production. A process simulation for SCS-Cupping processes was conducted. Based on these results a tool was manufactured and commissioned. Experimental results showed that material yields from the middle of the blank to the outer area of the cup wall. Due to the volume of material, the initial diameter can be reduced and material costs can be saved. In this paper different process settings and their effect on the amount of material, which yielded from the middle of the blank to its outside, are observed in a number of experimental series. A blank holder is added to the process in order to avoid wrinkling. The influence of this additional blank holder is therefore investigated in a first experimental set-up by varying blank holder force. In a further investigation the effects of two materials with different thicknesses is observed. Finally, an experimental series is conducted to observe the effect of blank diameter on the SCS-Cupping process. The results of this paper show that SCS-Cupping offers a promising potential for material savings and outline main effects for this technology.

  1. Some case studies of skewed (and other ab-normal) data distributions arising in low-level environmental research.

    PubMed

    Currie, L A

    2001-07-01

    Three general classes of skewed data distributions have been encountered in research on background radiation, chemical and radiochemical blanks, and low levels of 85Kr and 14C in the atmosphere and the cryosphere. The first class of skewed data can be considered to be theoretically, or fundamentally skewed. It is typified by the exponential distribution of inter-arrival times for nuclear counting events for a Poisson process. As part of a study of the nature of low-level (anti-coincidence) Geiger-Muller counter background radiation, tests were performed on the Poisson distribution of counts, the uniform distribution of arrival times, and the exponential distribution of inter-arrival times. The real laboratory system, of course, failed the (inter-arrival time) test--for very interesting reasons, linked to the physics of the measurement process. The second, computationally skewed, class relates to skewness induced by non-linear transformations. It is illustrated by non-linear concentration estimates from inverse calibration, and bivariate blank corrections for low-level 14C-12C aerosol data that led to highly asymmetric uncertainty intervals for the biomass carbon contribution to urban "soot". The third, environmentally, skewed, data class relates to a universal problem for the detection of excursions above blank or baseline levels: namely, the widespread occurrence of ab-normal distributions of environmental and laboratory blanks. This is illustrated by the search for fundamental factors that lurk behind skewed frequency distributions of sulfur laboratory blanks and 85Kr environmental baselines, and the application of robust statistical procedures for reliable detection decisions in the face of skewed isotopic carbon procedural blanks with few degrees of freedom.

  2. Estimation of genetic parameters and their sampling variances of quantitative traits in the type 2 modified augmented design

    USDA-ARS?s Scientific Manuscript database

    We proposed a method to estimate the error variance among non-replicated genotypes, thus to estimate the genetic parameters by using replicated controls. We derived formulas to estimate sampling variances of the genetic parameters. Computer simulation indicated that the proposed methods of estimatin...

  3. Method for replicating an array of nucleic acid probes

    DOEpatents

    Cantor, Charles R.; Przetakiewicz, Marek; Smith, Cassandra L.; Sano, Takeshi

    1998-01-01

    The invention relates to the replication of probe arrays and methods for replicating arrays of probes which are useful for the large scale manufacture of diagnostic aids used to screen biological samples for specific target sequences. Arrays created using PCR technology may comprise probes with 5'- and/or 3'-overhangs.

  4. Determining the lifetime of detectable amounts of gunshot residue on the hands of a shooter using laser-induced breakdown spectroscopy.

    PubMed

    Rosenberg, Matthew B; Dockery, Christopher R

    2008-11-01

    Laser-induced breakdown spectroscopy (LIBS) has been used to determine the period of time that a shooter will test positive for gunshot residue (GSR) after firing a revolver. Multiple rounds of primer were fired and samples collected at multiple hour intervals using an adhesive tape pressed against the skin. Samples were analyzed directly using a commercially available laser-induced breakdown spectrometer where barium emission (originating from barium nitrate in the primer) was observed. Population statistics were used to compare suspected GSR to a library of blank samples from which a threshold value was established. Statistically significant results, positive for GSR, are obtained 5.27 days after a firearm discharge using these techniques.

  5. Data Acceptance Criteria for Standardized Human-Associated Fecal Source Identification Quantitative Real-Time PCR Methods.

    PubMed

    Shanks, Orin C; Kelty, Catherine A; Oshiro, Robin; Haugland, Richard A; Madi, Tania; Brooks, Lauren; Field, Katharine G; Sivaganesan, Mano

    2016-05-01

    There is growing interest in the application of human-associated fecal source identification quantitative real-time PCR (qPCR) technologies for water quality management. The transition from a research tool to a standardized protocol requires a high degree of confidence in data quality across laboratories. Data quality is typically determined through a series of specifications that ensure good experimental practice and the absence of bias in the results due to DNA isolation and amplification interferences. However, there is currently a lack of consensus on how best to evaluate and interpret human fecal source identification qPCR experiments. This is, in part, due to the lack of standardized protocols and information on interlaboratory variability under conditions for data acceptance. The aim of this study is to provide users and reviewers with a complete series of conditions for data acceptance derived from a multiple laboratory data set using standardized procedures. To establish these benchmarks, data from HF183/BacR287 and HumM2 human-associated qPCR methods were generated across 14 laboratories. Each laboratory followed a standardized protocol utilizing the same lot of reference DNA materials, DNA isolation kits, amplification reagents, and test samples to generate comparable data. After removal of outliers, a nested analysis of variance (ANOVA) was used to establish proficiency metrics that include lab-to-lab, replicate testing within a lab, and random error for amplification inhibition and sample processing controls. Other data acceptance measurements included extraneous DNA contamination assessments (no-template and extraction blank controls) and calibration model performance (correlation coefficient, amplification efficiency, and lower limit of quantification). To demonstrate the implementation of the proposed standardized protocols and data acceptance criteria, comparable data from two additional laboratories were reviewed. The data acceptance criteria proposed in this study should help scientists, managers, reviewers, and the public evaluate the technical quality of future findings against an established benchmark. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  6. Adjustable extender for instrument module

    DOEpatents

    Sevec, J.B.; Stein, A.D.

    1975-11-01

    A blank extender module used to mount an instrument module in front of its console for repair or test purposes has been equipped with a rotatable mount and means for locking the mount at various angles of rotation for easy accessibility. The rotatable mount includes a horizontal conduit supported by bearings within the blank module. The conduit is spring-biased in a retracted position within the blank module and in this position a small gear mounted on the conduit periphery is locked by a fixed pawl. The conduit and instrument mount can be pulled into an extended position with the gear clearing the pawl to permit rotation and adjustment of the instrument.

  7. Method for making devices having intermetallic structures and intermetallic devices made thereby

    DOEpatents

    Paul, Brian Kevin; Wilson, Richard Dean; Alman, David Eli

    2004-01-06

    A method and system for making a monolithic intermetallic structure are presented. The structure is made from lamina blanks which comprise multiple layers of metals which are patternable, or intermetallic lamina blanks that are patternable. Lamina blanks are patterned, stacked and registered, and processed to form a monolithic intermetallic structure. The advantages of a patterned monolithic intermetallic structure include physical characteristics such as melting temperature, thermal conductivity, and corrosion resistance. Applications are broad, and include among others, use as a microreactor, heat recycling device, and apparatus for producing superheated steam. Monolithic intermetallic structures may contain one or more catalysts within the internal features.

  8. Development and Piloting of the Prosocial Attitude Blank.

    ERIC Educational Resources Information Center

    Wasson, Rebecca; And Others

    The Prosocial Attitude Blank (PAB) was designed to assess interpersonal values and ethical awareness of elementary school children. PAB was administered to 405 elementary students as one component of the evaluation of an intervention program designed to reduce interpersonal conflicts, increase literacy skills, and enhance children's ethical…

  9. Social Impacts Module (SIM) Transition

    DTIC Science & Technology

    2012-09-28

    User String The authorized user’s name to access the PAVE database. Applies only to Microsoft SQL Server; leave blank, otherwise. passwd String The...otherwise. passwd String The password if an authorized user’s name is required; otherwise, leave blank driver String The class name for the driver to

  10. Lowest cost due to highest productivity and highest quality

    NASA Astrophysics Data System (ADS)

    Wenk, Daniel

    2003-03-01

    Since global purchasing in the automotive industry has been taken up all around the world there is one main key factor that makes a TB-supplier today successful: Producing highest quality at lowest cost. The fact that Tailored Blanks, which today may reach up to 1/3 of a car body weight, are purchased on the free market but from different steel suppliers, especially in Europe and NAFTA, the philosophy on OEM side has been changing gradually towards tough evaluation criteria. "No risk at the stamping side" calls for top quality Tailored- or Tubular Blank products. Outsourcing Tailored Blanks has been starting in Japan but up to now without any quality request from the OEM side like ISO 13919-1B (welding quality standard in Europe and USA). Increased competition will automatically push the quality level and the ongoing approach to combine high strength steel with Tailored- and Tubular Blanks will ask for even more reliable system concepts which enables to weld narrow seams at highest speed. Beside producing quality, which is the key to reduce one of the most important cost driver "material scrap," in-line quality systems with true and reliable evaluation is going to be a "must" on all weld systems. Traceability of all process related data submitted to interfaces according to customer request in combination with ghost-shift-operation of TB systems are tomorrow's state-of-the-art solutions of Tailored Blank-facilities.

  11. Inverse Analysis to Formability Design in a Deep Drawing Process

    NASA Astrophysics Data System (ADS)

    Buranathiti, Thaweepat; Cao, Jian

    Deep drawing process is an important process adding values to flat sheet metals in many industries. An important concern in the design of a deep drawing process generally is formability. This paper aims to present the connection between formability and inverse analysis (IA), which is a systematical means for determining an optimal blank configuration for a deep drawing process. In this paper, IA is presented and explored by using a commercial finite element software package. A number of numerical studies on the effect of blank configurations to the quality of a part produced by a deep drawing process were conducted and analyzed. The quality of the drawing processes is numerically analyzed by using an explicit incremental nonlinear finite element code. The minimum distance between elemental principal strains and the strain-based forming limit curve (FLC) is defined as tearing margin to be the key performance index (KPI) implying the quality of the part. The initial blank configuration has shown that it plays a highly important role in the quality of the product via the deep drawing process. In addition, it is observed that if a blank configuration is not greatly deviated from the one obtained from IA, the blank can still result a good product. The strain history around the bottom fillet of the part is also observed. The paper concludes that IA is an important part of the design methodology for deep drawing processes.

  12. Quartz 9-inch size mask blanks for ArF PSM (Phase Shift Mask)

    NASA Astrophysics Data System (ADS)

    Harashima, Noriyuki; Isozaki, Tatsuya; Kawanishi, Arata; Kanai, Shuichiro; Kageyama, Kagehiro; Iso, Hiroyuki; Chishima, Tatsuya

    2017-07-01

    Semiconductor technology nodes are steadily miniaturizing. On the other hand, various efforts have been made to reduce costs, mass production lines have shifted from 200 mmφ of Si wafer to 300 mmφ, and technology development of Si wafer 450 mmφ is also in progress. As a photomask, 6-inch size binary Cr mask has been used for many years, but in recent years, the use of 9-inch binary Cr masks for Proximity Lithography Process in automotive applications, MEMS, packages, etc. has increased, and cost reduction has been taken. Since the miniaturization will progress in the above applications in the future, products corresponding to miniaturization are also desired in 9-inch photomasks. The high grade Cr - binary mask blanks used in proximity exposure process, there is a prospect of being able to use it by ULVAC COATING CORPORATION's tireless research. As further demands for miniaturization, KrF and ArF Lithography Process, which are used for steppers and scanners , there are also a demand for 9-inch size Mask Blanks. In ULVAC COATING CORPORATION, we developed a 9 - inch size KrF PSM mask Blanks prototype in 2016 and proposed a new high grade 9 - inch photomask. This time, we have further investigated and developed 9-inch size ArF PSM Mask Blanks corresponding to ArF Lithography Process, so we report it.

  13. Production of the 4.26 m ZERODUR mirror blank for the Advanced Technology Solar telescope (ATST)

    NASA Astrophysics Data System (ADS)

    Jedamzik, Ralf; Werner, Thomas; Westerhoff, Thomas

    2014-07-01

    The Daniel K. Inouye Solar Telescope (DKIST, formerly the Advanced Technology Solar Telescope, ATST) will be the most powerful solar telescope in the world. It is currently being built by the Association of Universities for Research in Astronomy (AURA) in a height of 3000 m above sea level on the mountain Haleakala of Maui, Hawaii. The primary mirror blank of diameter 4.26 m is made of the extremely low thermal expansion glass ceramic ZERODUR® of SCHOTT AG Advanced Optics. The DKIST primary mirror design is extremely challenging. With a mirror thickness of only 78 to 85 mm it is the smallest thickness ever machined on a mirror of 4.26 m in diameter. Additionally the glassy ZERODUR® casting is one of the largest in size ever produced for a 4 m class ZERODUR® mirror blank. The off axis aspherical mirror surface required sophisticated grinding procedures to achieve the specified geometrical tolerance. The small thickness of about 80 mm required special measures during processing, lifting and transport. Additionally acid etch treatment was applied to the convex back-surface and the conical shaped outer diameter surface to improve the strength of the blank. This paper reports on the challenging tasks and the achievements on the material property and dimensional specification parameter during the production of the 4.26 m ZERODUR® primary mirror blank for AURA.

  14. Communist China’s Progress in Inorganic, Organic, and Physical Chemistry in Recent Decade

    DTIC Science & Technology

    1960-03-16

    situation, develp t ms bin- dered. ?ollwving the revival of nastieal tahvoloe In World War I, Inorganic chemstry , lMke other branches of che•strj, mde seem...in high-density sam~ples." Looking back at the devolou t of our inorganic chemstry in the pest decadse, we believe that today’s echievemt from a blank...8217, and rich chemical resources are Iamting for. solutions, Therefore, Our Inorganic chemstry workers must bear in mind the development of Chinats

  15. Developments in ICP-MS: electrochemically modulated liquid chromatography for the clean-up of ICP-MS blanks and reduction of matrix effects by flow injection ICP-MS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gross, Cory Thomas

    2008-01-01

    The focus of this dissertation is the development of techniques with which to enhance the existing abilities of inductively coupled plasma mass spectrometry (ICP-MS). ICP-MS is a powerful technique for trace metal analysis in samples of many types, but like any technique it has certain strengths and weaknesses. Attempts are made to improve upon those strengths and to overcome certain weaknesses.

  16. Iridescent Virus and Nosema ceranae Linked to Honeybee Colony Collapse Disorder

    DTIC Science & Technology

    2010-12-01

    recorded and exhibited several peaks and crashes until it declined by approximate geometric decay to extinction (Figure 2). Of the six RNA bee viruses...counts for all unique Iridovirus peptides in each sample. 19 Blank 20 LITERATURE CITED 1. Debnam, S . et al. Bee Culture 2008, 137, 30. 2. Higes...Pathol. 1978, 31, 368. 23. Verma, S . K. P. S . Phogat, Indian Bee J. 1982,44, 36. 24. Moore, N. F., Kelly, D. C. J. Invertebr. Pathol. 1980, 36,415

  17. Using Distinct Sectors in Media Sampling and Full Media Analysis to Detect Presence of Documents from a Corpus

    DTIC Science & Technology

    2012-09-01

    relative performance of several conventional SQL and NoSQL databases with a set of one billion file block hashes. Digital Forensics, Sector Hashing, Full... NoSQL databases with a set of one billion file block hashes. v THIS PAGE INTENTIONALLY LEFT BLANK vi Table of Contents List of Acronyms and...Operating System NOOP No Operation assembly instruction NoSQL “Not only SQL” model for non-relational database management NSRL National Software

  18. Development of Methodology and Technology for Identifying and Quantifying Emission Products from Open Burning and Open Detonation Thermal Treatment Methods. Bangbox Test Series. Volume 2. Test Development

    DTIC Science & Technology

    1992-01-01

    Calculated by the Carbon Balance and by the C -V M ethod . ...................................... ... ... ... ... ... 6-8 x I I Table 6.3 EF for the...A-i APPENDIX B. SAMPLING AND DETERMINATION OF POLYCHLORINATED DIBENZODIOXINS AND DIBENZOFURANS ................. B-13 APPENDIX C . DISTRIBUTION... C -I I I I I I I I I I I I I I xiii I INTENTIONALLY BLANK xiv --I IACKNOWLEDGEMENTS I The following

  19. Derived Basic Ability Factors: A Factor Analysis Replication Study.

    ERIC Educational Resources Information Center

    Lee, Mickey, M.; Lee, Lynda Newby

    The purpose of this study was to replicate the study conducted by Potter, Sagraves, and McDonald to determine whether their recommended analysis could separate criterion variables into similar factors that were stable from year to year and from school to school. The replication samples consisted of all students attending Louisiana State University…

  20. Method for replicating an array of nucleic acid probes

    DOEpatents

    Cantor, C.R.; Przetakiewicz, M.; Smith, C.L.; Sano, T.

    1998-08-18

    The invention relates to the replication of probe arrays and methods for replicating arrays of probes which are useful for the large scale manufacture of diagnostic aids used to screen biological samples for specific target sequences. Arrays created using PCR technology may comprise probes with 5{prime}- and/or 3{prime}-overhangs. 16 figs.

  1. Gambling, Risk-Taking, and Antisocial Behavior: A Replication Study Supporting the Generality of Deviance.

    PubMed

    Mishra, Sandeep; Lalumière, Martin L; Williams, Robert J

    2017-03-01

    Research suggests that high frequency gambling is a component of the "generality of deviance", which describes the observation that various forms of risky and antisocial behavior tend to co-occur among individuals. Furthermore, risky and antisocial behaviors have been associated with such personality traits as low self-control, and impulsivity, and sensation-seeking. We conducted a replication (and extension) of two previous studies examining whether high frequency gambling is part of the generality of deviance using a large and diverse community sample (n = 328). This study was conducted as a response to calls for more replication studies in the behavioral and psychological sciences (recent systematic efforts suggest that a significant proportion of psychology studies do not replicate). The results of the present study largely replicate those previously found, and in many cases, we observed stronger associations among measures of gambling, risk-taking, and antisocial behavior in this diverse sample. Together, this study provides evidence for the generality of deviance inclusive of gambling (and, some evidence for the replicability of research relating to gambling and individual differences).

  2. Information Operations and FATA Integration into the National Mainstream

    DTIC Science & Technology

    2012-09-01

    Edward L. Fisher THIS PAGE INTENTIONALLY LEFT BLANK i REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 Public reporting burden for this...LEFT BLANK vii TABLE OF CONTENTS I . INTRODUCTION ............................................................................................. 1...39 ix i . Computer Network Operations .................................. 40 j. CNO as an IO Core Capability .................................... 40

  3. Nitrogen-Noble Gas Static Mass Sepectrometry of Genesis Collector Materials

    NASA Astrophysics Data System (ADS)

    Marty, B.; Burnard, P.; Zimmermann, L.; Robert, P.

    2005-03-01

    Gases (N, Ne, Ar) are extracted from Au-coated sapphire and diamond-like carbon collectors using an F2 excimer laser, without blank contributions the substrate. N is purified using a low blank CuO/Cu cycle prior to analysis by high resolution multicollector mass spectrometer.

  4. Some Data Concerning the Vocational Preference Inventory Scales and the Strong Vocational Interest Blank

    ERIC Educational Resources Information Center

    Cockriel, Irvin W.

    1972-01-01

    Occupational scales of the Vocational Preference Inventory were correlated with the Basic Interest scales of the Strong Vocational Interest Blank. The 285 subjects were women freshmen in a College of Education. The results indicate that the scales are not highly correlated. (Author)

  5. 76 FR 50537 - Regulatory Guidance Concerning Household Goods Carriers Requiring Shippers To Sign Blank or...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-15

    ... Concerning Household Goods Carriers Requiring Shippers To Sign Blank or Incomplete Documents AGENCY: Federal.... Basis for This Notice The Agency has received numerous consumer complaints concerning household goods.... The FMCSA is issuing this regulatory guidance to eliminate any ambiguity or confusion concerning the...

  6. Certified reference materials for testing of the presence/absence of Staphylococcus aureus enterotoxin A (SEA) in cheese.

    PubMed

    Zeleny, Reinhard; Nia, Yacine; Schimmel, Heinz; Mutel, Isabelle; Hennekinne, Jacques-Antoine; Emteborg, Håkan; Charoud-Got, Jean; Auvray, Frédéric

    2016-08-01

    Staphylococcal enterotoxins (SEs) account for a substantial number of food-poisoning outbreaks. European legislation (Commission Regulation 1441/2007) stipulates the reference procedure for SE analysis in milk and dairy products, which is based on extraction, dialysis concentration and immunochemical detection using one of two approved assays (VIDAS(®) SET2, Ridascreen(®) SET Total). However, certified reference materials (CRMs) are lacking to support laboratories in performing reliable detection of Staphylococcus aureus enterotoxin A (SEA) in relevant matrices at sub-nanogram per gram levels. The certification of a set of three reference materials (blank and two SEA-containing materials) for testing of the presence/absence of SEA in cheese is described. The reference procedure was applied in an intercomparison with 15 laboratories, and results were reported in a qualitative manner (presence or absence of SEA in the sample). No false-negative or false-positive results were obtained. The certified values were stated as diagnostic specificity (blank material) or diagnostic sensitivity (SEA-containing materials) and were 100 % in all cases. Stability studies demonstrated suitable material stability when stored cooled or frozen. An in-house study on the recovery of SEA in the cheese materials using a double-sandwich enzyme-linked immunosorbent assay (ELISA) revealed comparable recovery values of around 45 % at the two spiking levels and in both the SEA-containing CRMs as well as blank CRM freshly spiked prior to analysis. The values were also comparable over time and among different analysts. The materials provide valuable support to laboratories for method validation and method performance verification and will increase the reliability of measuring SEA in cheese.

  7. Reproducibility of R-fMRI metrics on the impact of different strategies for multiple comparison correction and sample sizes.

    PubMed

    Chen, Xiao; Lu, Bin; Yan, Chao-Gan

    2018-01-01

    Concerns regarding reproducibility of resting-state functional magnetic resonance imaging (R-fMRI) findings have been raised. Little is known about how to operationally define R-fMRI reproducibility and to what extent it is affected by multiple comparison correction strategies and sample size. We comprehensively assessed two aspects of reproducibility, test-retest reliability and replicability, on widely used R-fMRI metrics in both between-subject contrasts of sex differences and within-subject comparisons of eyes-open and eyes-closed (EOEC) conditions. We noted permutation test with Threshold-Free Cluster Enhancement (TFCE), a strict multiple comparison correction strategy, reached the best balance between family-wise error rate (under 5%) and test-retest reliability/replicability (e.g., 0.68 for test-retest reliability and 0.25 for replicability of amplitude of low-frequency fluctuations (ALFF) for between-subject sex differences, 0.49 for replicability of ALFF for within-subject EOEC differences). Although R-fMRI indices attained moderate reliabilities, they replicated poorly in distinct datasets (replicability < 0.3 for between-subject sex differences, < 0.5 for within-subject EOEC differences). By randomly drawing different sample sizes from a single site, we found reliability, sensitivity and positive predictive value (PPV) rose as sample size increased. Small sample sizes (e.g., < 80 [40 per group]) not only minimized power (sensitivity < 2%), but also decreased the likelihood that significant results reflect "true" effects (PPV < 0.26) in sex differences. Our findings have implications for how to select multiple comparison correction strategies and highlight the importance of sufficiently large sample sizes in R-fMRI studies to enhance reproducibility. Hum Brain Mapp 39:300-318, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  8. Polydimethylsiloxane rod extraction, a novel technique for the determination of organic micropollutants in water samples by thermal desorption-capillary gas chromatography-mass spectrometry.

    PubMed

    Montero, L; Popp, P; Paschke, A; Pawliszyn, J

    2004-01-30

    A novel, simple and inexpensive approach to absorptive extraction of organic compounds from environmental samples is presented. It consists of a polydimethylsiloxane rod used as an extraction media, enriched with analytes during shaking, then thermally desorbed and analyzed by GC-MS. Its performance was illustrated and evaluated for the enrichment of sub- to ng/l of selected chlorinated compounds (chlorobenzenes and polychlorinated biphenyls) in water samples. The new approach was compared to the stir bar sorptive extraction performance. A natural ground water sample from Bitterfeld, Germany, was also extracted using both methods, showing good agreement. The proposed approach presented good linearity, high sensitivity, good blank levels and recoveries comparable to stir bars, together with advantages such as simplicity, lower cost and higher feasibility.

  9. Rapid LC-MS Determination of Acromelic Acids A and B, Toxic Constituents of the Mushroom Paralepistopsis acromelalga.

    PubMed

    Yoshioka, Naoki; Ouchi, Hitoshi; Kan, Toshiyuki; Yoshida, Masashi; Nomura, Motoyuki

    2017-01-01

    A rapid LC-MS method was developed for determination of acromelic acids A and B, which are toxic constituents of Paralepistopsis acromelalga (=Clitocybe acromelalga), in mushroom samples. Acromelic acids were extracted twice with 50% methanol and the extract was passed through a syringe filter, and then analyzed by LC-MS. The LC separation was performed on a multi-mode ODS column. The recoveries of acromelic acids A and B spiked into blank mushroom samples at 2.5 μg/g were 93 and 74%, respectively. This method was applied to the remaining mushroom sample from a food poisoning case. Acromelic acids A and B were detected at 2.0 and 1.4 μg/g, respectively, in the remaining sample. Another toxic constituent, which appeared to be clitidine, was also detected in the sample.

  10. Data Validation Package - April and July 2015 Groundwater and Surface Water Sampling at the Gunnison, Colorado, Processing Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Linard, Joshua; Campbell, Sam

    This event included annual sampling of groundwater and surface water locations at the Gunnison, Colorado, Processing Site. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites. Samples were collected from 28 monitoring wells, three domestic wells, and six surface locations in April at the processing site as specified in the 2010 Ground Water Compliance Action Plan for the Gunnison, Colorado, Processing Site. Domestic wells 0476 and 0477 were sampled in July because the homes were unoccupied in April, and the wells were not in use. Duplicate samplesmore » were collected from locations 0113, 0248, and 0477. One equipment blank was collected during this sampling event. Water levels were measured at all monitoring wells that were sampled. No issues were identified during the data validation process that requires additional action or follow-up.« less

  11. Sequential derivatization of polar organic compounds in cloud water using O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride, N,O-bis(trimethylsilyl)trifluoroacetamide, and gas-chromatography/mass spectrometry analysis.

    PubMed

    Sagona, Jessica A; Dukett, James E; Hawley, Harmonie A; Mazurek, Monica A

    2014-10-03

    Cloud water samples from Whiteface Mountain, NY were used to develop a combined sampling and gas chromatography-mass spectrometric (GCMS) protocol for evaluating the complex mixture of highly polar organic compounds (HPOC) present in this atmospheric medium. Specific HPOC of interest were mono- and di keto-acids which are thought to originate from photochemical reactions of volatile unsaturated hydrocarbons from biogenic and manmade emissions and be a major fraction of atmospheric carbon. To measure HPOC mixtures and the individual keto-acids in cloud water, samples first must be derivatized for clean elution and measurement, and second, have low overall background of the target species as validated by GCMS analysis of field and laboratory blanks. Here, we discuss a dual derivatization method with PFBHA and BSTFA which targets only organic compounds that contain functional groups reacting with both reagents. The method also reduced potential contamination by minimizing the amount of sample processing from the field through the GCMS analysis steps. Once derivatized only gas chromatographic separation and selected ion monitoring (SIM) are needed to identify and quantify the polar organic compounds of interest. Concentrations of the detected total keto-acids in individual cloud water samples ranged from 27.8 to 329.3ngmL(-1) (ppb). Method detection limits for the individual HPOC ranged from 0.17 to 4.99ngmL(-1) and the quantification limits for the compounds ranged from 0.57 to 16.64ngmL(-1). The keto-acids were compared to the total organic carbon (TOC) results for the cloud water samples with concentrations of 0.607-3.350mgL(-1) (ppm). GCMS analysis of all samples and blanks indicated good control of the entire collection and analysis steps. Selected ion monitoring by GCMS of target keto-acids was essential for screening the complex organic carbon mixtures present at low ppb levels in cloud water. It was critical for ensuring high levels of quality assurance and quality control and for the correct identification and quantification of key marker compounds. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Standardization and validation of a cytometric bead assay to assess antibodies to multiple Plasmodium falciparum recombinant antigens

    PubMed Central

    2012-01-01

    Background Multiplex cytometric bead assay (CBA) have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Methods Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Results Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from <0.0001 - 0.004), and antibodies to variants of the same antigen were accurately distinguished within a multiplex reaction. Plasma dilutions of 1:100 or 1:200 were optimal for all antigens for CBA testing. Plasma diluted in a buffer containing 0.05% sodium azide, 0.5% polyvinylalcohol, and 0.8% polyvinylpyrrolidone had the lowest background activity. CBA median fluorescence intensity (MFI) values with 1,000 antigen-conjugated beads/well did not differ significantly from MFI with 5,000 beads/well. CBA and ELISA results correlated well for all antigens except apical membrane antigen-1 (AMA-1). CBA testing produced a greater range of values in samples from malaria endemic areas and less background reactivity for blank samples than ELISA. Conclusion With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in positive samples and lower background readings for blank samples than ELISA. PMID:23259607

  13. Total Mercury in Surface and Deep Waters in the Western and Eastern Mediterranean Sea

    NASA Astrophysics Data System (ADS)

    Varde', M.; Cofone, F.; Servidio, A.; Rosselli, A.; Hedgecock, I. M.; Ammoscato, I.; Mannarino, V.; Sprovieri, F.; Gensini, M.; Pirrone, N.

    2014-12-01

    In the framework of the Italian National Research Council (CNR) Med-Oceanor measurement program and as part of the Global Mercury Observation System (GMOS) objectives, we performed two cruise campaigns with the CNR's Research Vessel (RV) Urania, in the western and eastern Mediterranean Basin, in the summers of 2012 and 2013. Total Mercury (THg) concentration in seawater was systematically measured at different depths from the sea bottom to the surface. A total of 155 surface and deep seawater samples at 25 selected stations were collected during the cruise campaigns using a stainless-steel rosette system on which 24 Niskin bottles (10L) were mounted. Continuous monitoring of temperature, conductivity, salinity and oxygen with depth were obtained by CTD measurements. All fluorinated containers were cleaned prior to use following GMOS SOPs. The chemical reagents used were suitable for ultra-trace Hg analysis. After sampling, samples were preserved by adding HCl solution to the sample bottles, which were refrigerated during transportation and analyzed within four weeks of the end of the oceanographic campaign. Sea water samples were analyzed in the laboratory following the US-EPA 1631 method revision E (US-EPA, 2002). To assess the critical issues related to mercury (Hg) contamination and to prevent leakage of Hg through volatilization we used all necessary precautions for sampling, sample stabilization, preservation and subsequent analysis in the laboratory. Quality assurance and quality control were performed using transport blanks, laboratory blanks and use of seawater certified reference materials. The accuracy of the analytical procedures for the determination of THg in sea water was corroborated by participation in a global inter-laboratory comparison study for THg in natural waters. THg concentrations in surface and deep waters found in the Mediterranean basin during the last two cruise campaigns Med-Oceanor as well as the THg measurements in sea water collected in the other programs and oceanographic campaigns will help to further our understanding of Hg marine distribution and its impact on the biogeochemical cycle of Hg in the open ocean.

  14. Experimental toxicology: Issues of statistics, experimental design, and replication.

    PubMed

    Briner, Wayne; Kirwan, Jeral

    2017-01-01

    The difficulty of replicating experiments has drawn considerable attention. Issues with replication occur for a variety of reasons ranging from experimental design to laboratory errors to inappropriate statistical analysis. Here we review a variety of guidelines for statistical analysis, design, and execution of experiments in toxicology. In general, replication can be improved by using hypothesis driven experiments with adequate sample sizes, randomization, and blind data collection techniques. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Information model construction of MES oriented to mechanical blanking workshop

    NASA Astrophysics Data System (ADS)

    Wang, Jin-bo; Wang, Jin-ye; Yue, Yan-fang; Yao, Xue-min

    2016-11-01

    Manufacturing Execution System (MES) is one of the crucial technologies to implement informatization management in manufacturing enterprises, and the construction of its information model is the base of MES database development. Basis on the analysis of the manufacturing process information in mechanical blanking workshop and the information requirement of MES every function module, the IDEF1X method was adopted to construct the information model of MES oriented to mechanical blanking workshop, and a detailed description of the data structure feature included in MES every function module and their logical relationship was given from the point of view of information relationship, which laid the foundation for the design of MES database.

  16. Trajectory of Externalizing Child Behaviors in a KEEP Replication

    ERIC Educational Resources Information Center

    Uretsky, Mathew C.; Lee, Bethany R.; Greeno, Elizabeth J.; Barth, Richard P.

    2017-01-01

    Objective: The purpose of this study is to examine the correlates of child behavior change over time in a replication of the KEEP intervention. Method: The study sample was drawn from the treatment group of the Maryland replication of KEEP (n=65). Change over time was analyzed using multilevel linear mixed modeling. Results: Parents' use of…

  17. Validation of the self-beliefs related to social anxiety scale: a replication and extension.

    PubMed

    Wong, Quincy J J; Moulds, Michelle L; Rapee, Ronald M

    2014-06-01

    The importance of self-beliefs in prominent models of social phobia has led to the development of measures that tap this cognitive construct. The Self-Beliefs Related to Social Anxiety (SBSA) Scale is one such measure and taps the three maladaptive belief types proposed in Clark and Wells's model of social phobia. This study aimed to replicate and extend previous research on the psychometric properties of the SBSA. Replicating previous research, in an (undiagnosed) undergraduate sample (n = 235), the SBSA was found to have a correlated three-factor structure using confirmatory factor analyses, and the SBSA and its subscales demonstrated good internal consistency and test-retest reliability. The SBSA and its subscales also had unique relationships with social anxiety and depression, the majority of which replicated previous research. Extending previous research, the SBSA and its subscales showed good incremental validity in the undergraduate sample and good discriminative validity using the undergraduate sample and a sample of individuals with social phobia (n = 33). The SBSA's strong theoretical basis and the findings of this study suggest that the SBSA is an ideal research and clinical tool to assess the cognitions characteristic of social phobia. © The Author(s) 2013.

  18. Exploring the roles of spectral detail and intonation contour in speech intelligibility: an FMRI study.

    PubMed

    Kyong, Jeong S; Scott, Sophie K; Rosen, Stuart; Howe, Timothy B; Agnew, Zarinah K; McGettigan, Carolyn

    2014-08-01

    The melodic contour of speech forms an important perceptual aspect of tonal and nontonal languages and an important limiting factor on the intelligibility of speech heard through a cochlear implant. Previous work exploring the neural correlates of speech comprehension identified a left-dominant pathway in the temporal lobes supporting the extraction of an intelligible linguistic message, whereas the right anterior temporal lobe showed an overall preference for signals clearly conveying dynamic pitch information [Johnsrude, I. S., Penhune, V. B., & Zatorre, R. J. Functional specificity in the right human auditory cortex for perceiving pitch direction. Brain, 123, 155-163, 2000; Scott, S. K., Blank, C. C., Rosen, S., & Wise, R. J. Identification of a pathway for intelligible speech in the left temporal lobe. Brain, 123, 2400-2406, 2000]. The current study combined modulations of overall intelligibility (through vocoding and spectral inversion) with a manipulation of pitch contour (normal vs. falling) to investigate the processing of spoken sentences in functional MRI. Our overall findings replicate and extend those of Scott et al. [Scott, S. K., Blank, C. C., Rosen, S., & Wise, R. J. Identification of a pathway for intelligible speech in the left temporal lobe. Brain, 123, 2400-2406, 2000], where greater sentence intelligibility was predominately associated with increased activity in the left STS, and the greatest response to normal sentence melody was found in right superior temporal gyrus. These data suggest a spatial distinction between brain areas associated with intelligibility and those involved in the processing of dynamic pitch information in speech. By including a set of complexity-matched unintelligible conditions created by spectral inversion, this is additionally the first study reporting a fully factorial exploration of spectrotemporal complexity and spectral inversion as they relate to the neural processing of speech intelligibility. Perhaps surprisingly, there was little evidence for an interaction between the two factors-we discuss the implications for the processing of sound and speech in the dorsolateral temporal lobes.

  19. A dissociation between engagement and learning: Enthusiastic instructions fail to reliably improve performance on a memory task.

    PubMed

    Motz, Benjamin A; de Leeuw, Joshua R; Carvalho, Paulo F; Liang, Kaley L; Goldstone, Robert L

    2017-01-01

    Despite widespread assertions that enthusiasm is an important quality of effective teaching, empirical research on the effect of enthusiasm on learning and memory is mixed and largely inconclusive. To help resolve these inconsistencies, we conducted a carefully-controlled laboratory experiment, investigating whether enthusiastic instructions for a memory task would improve recall accuracy. Scripted videos, either enthusiastic or neutral, were used to manipulate the delivery of task instructions. We also manipulated the sequence of learning items, replicating the spacing effect, a known cognitive technique for memory improvement. Although spaced study reliably improved test performance, we found no reliable effect of enthusiasm on memory performance across two experiments. We did, however, find that enthusiastic instructions caused participants to respond to more item prompts, leaving fewer test questions blank, an outcome typically associated with increased task motivation. We find no support for the popular claim that enthusiastic instruction will improve learning, although it may still improve engagement. This dissociation between motivation and learning is discussed, as well as its implications for education and future research on student learning.

  20. A dissociation between engagement and learning: Enthusiastic instructions fail to reliably improve performance on a memory task

    PubMed Central

    de Leeuw, Joshua R.; Carvalho, Paulo F.; Liang, Kaley L.; Goldstone, Robert L.

    2017-01-01

    Despite widespread assertions that enthusiasm is an important quality of effective teaching, empirical research on the effect of enthusiasm on learning and memory is mixed and largely inconclusive. To help resolve these inconsistencies, we conducted a carefully-controlled laboratory experiment, investigating whether enthusiastic instructions for a memory task would improve recall accuracy. Scripted videos, either enthusiastic or neutral, were used to manipulate the delivery of task instructions. We also manipulated the sequence of learning items, replicating the spacing effect, a known cognitive technique for memory improvement. Although spaced study reliably improved test performance, we found no reliable effect of enthusiasm on memory performance across two experiments. We did, however, find that enthusiastic instructions caused participants to respond to more item prompts, leaving fewer test questions blank, an outcome typically associated with increased task motivation. We find no support for the popular claim that enthusiastic instruction will improve learning, although it may still improve engagement. This dissociation between motivation and learning is discussed, as well as its implications for education and future research on student learning. PMID:28732087

  1. Importance of the efficiency of double-stranded DNA formation in cDNA synthesis for the imprecision of microarray expression analysis.

    PubMed

    Thormar, Hans G; Gudmundsson, Bjarki; Eiriksdottir, Freyja; Kil, Siyoen; Gunnarsson, Gudmundur H; Magnusson, Magnus Karl; Hsu, Jason C; Jonsson, Jon J

    2013-04-01

    The causes of imprecision in microarray expression analysis are poorly understood, limiting the use of this technology in molecular diagnostics. Two-dimensional strandness-dependent electrophoresis (2D-SDE) separates nucleic acid molecules on the basis of length and strandness, i.e., double-stranded DNA (dsDNA), single-stranded DNA (ssDNA), and RNA·DNA hybrids. We used 2D-SDE to measure the efficiency of cDNA synthesis and its importance for the imprecision of an in vitro transcription-based microarray expression analysis. The relative amount of double-stranded cDNA formed in replicate experiments that used the same RNA sample template was highly variable, ranging between 0% and 72% of the total DNA. Microarray experiments showed an inverse relationship between the difference between sample pairs in probe variance and the relative amount of dsDNA. Approximately 15% of probes showed between-sample variation (P < 0.05) when the dsDNA percentage was between 12% and 35%. In contrast, only 3% of probes showed between-sample variation when the dsDNA percentage was 69% and 72%. Replication experiments of the 35% dsDNA and 72% dsDNA samples were used to separate sample variation from probe replication variation. The estimated SD of the sample-to-sample variation and of the probe replicates was lower in 72% dsDNA samples than in 35% dsDNA samples. Variation in the relative amount of double-stranded cDNA synthesized can be an important component of the imprecision in T7 RNA polymerase-based microarray expression analysis. © 2013 American Association for Clinical Chemistry

  2. The Fiscal Blank Check Policy and Its Impact on Operation Iraqi Freedom

    DTIC Science & Technology

    2006-12-01

    facilities across Iraq has a significant logistical and financial tail associated with it. The increase in food and beverages (to the point of luxuries) has...THIS PAGE INTENTIONALLY LEFT BLANK v ABSTRACT Congress passed declaration of war language for World Wars I and...78 V . CONCLUSION AND RECOMMENDATIONS

  3. Intellectual Property Rights for Digital Design and Manufacturing: Issues and Recommendations

    DTIC Science & Technology

    2014-06-30

    for Public Release, Distribution Unlimited. iv This page intentionally left blank. Distribution A: Approved for...Distribution A: Approved for Public Release, Distribution Unlimited. viii This page intentionally left blank...challenges requires an analysis of intellectual property management and recommendations for its use in a cooperative as well as competitive market

  4. Organizational Strategic Planning and Execution: Should Governmental Organizations Rely on Strategic Planning for the Success of the Organization?

    DTIC Science & Technology

    2007-06-01

    THIS PAGE INTENTIONALLY LEFT BLANK i NSN 7540-01-280-5500 Standard Form 298 (Rev. 2-89) Prescribed by ANSI Std. 239-18...4 I . INTRODUCTION............................................................................................. 7 A. SCOPE...6 THIS PAGE INTENTIONALLY LEFT BLANK 7 I . INTRODUCTION A. SCOPE The intent

  5. Strong Vocational Interest Blank Scores for Junior College Students in Five Curricula.

    ERIC Educational Resources Information Center

    Smith, Stuart E.

    An investigation was conducted to determine if students in five junior college curricula could be differentiated by the Strong Vocational Interest Blank (SVIB) scores and if such differentiation could be improved by using several scores in combination rather than single scores separately. The SVIB was administered to 130 students at Alfred…

  6. 75 FR 9436 - Aleris Blanking and Rim Products, Inc., a Division of Aleris International, Inc., Terre Haute, IN...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-02

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-72,041] Aleris Blanking and Rim Products, Inc., a Division of Aleris International, Inc., Terre Haute, IN; Notice of Affirmative Determination Regarding Application for Reconsideration By application dated January 29, 2010, the petitioner...

  7. 47 CFR 73.642 - Subscription TV service.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... available to the FCC upon request. (d) The use of the visual vertical blanking interval or an aural... programming may be used only upon specific FCC authorization. Letter requests to use either the video blanking intervals or aural subcarriers during periods of non-subscription programming are to be sent to the FCC in...

  8. 47 CFR 73.642 - Subscription TV service.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... available to the FCC upon request. (d) The use of the visual vertical blanking interval or an aural... programming may be used only upon specific FCC authorization. Letter requests to use either the video blanking intervals or aural subcarriers during periods of non-subscription programming are to be sent to the FCC in...

  9. Predetermined Flake Production at the Lower/Middle Paleolithic Boundary: Yabrudian Scraper-Blank Technology

    PubMed Central

    Shimelmitz, Ron; Kuhn, Steven L.; Ronen, Avraham; Weinstein-Evron, Mina

    2014-01-01

    While predetermined débitage technologies are recognized beginning with the middle Acheulian, the Middle Paleolithic is usually associated with a sharp increase in their use. A study of scraper-blank technology from three Yabrudian assemblages retrieved from the early part of the Acheulo-Yabrudian complex of Tabun Cave (ca. 415–320 kyr) demonstrates a calculated and preplanned production, even if it does not show the same complexity and elaboration as in the Levallois technology. These scraper dominated assemblages show an organization of production based on an intensive use of predetermination blank technology already in place at the end of the Lower Paleolithic of the Levant. These results provide a novel perspective on the differences and similarities between the Lower and Middle Paleolithic industries. We suggest that there was a change in the paradigm in the way hominins exploited stone tools: in many Middle Paleolithic assemblages the potential of the stone tools for hafting was a central feature, in the Lower Paleolithic ergonometric considerations of manual prehension were central to the design of blanks and tools. PMID:25192429

  10. Replication of associations between LRP5 and ESRRA variants and bone density in premenopausal women.

    PubMed

    Giroux, S; Elfassihi, L; Cole, D E C; Rousseau, F

    2008-12-01

    Replication is a critical step to validate positive genetic associations. In this study, we tested two previously reported positive associations. The low density lipoprotein receptor-related protein 5 (LRP5) Val667Met and lumbar spine bone density are replicated. This result is in line with results from large consortiums such as Genomos. However, the estrogen-related receptor alpha (ESRRA) repeat in the promoter is not replicated although the polymorphism studied was functional and could have been a causative variant. We sought to validate associations previously reported between LRP5 V667M polymorphism and lumbar spine (LS, p = 0.013) and femoral neck (FN, p = 0.0002) bone mineral density (BMD), and between ESRRA 23 base pair repeat polymorphism and LS BMD (p = 0.0036) in a sample of premenopausal Caucasian women using an independent sample. For the replication sample, we recruited 673 premenopausal women from the Toronto metropolitan area. All women were Caucasian and had BMD measured. LRP5 V667M was genotyped by allele-specific PCR and ESRRA repeats by sizing of PCR products on agarose gels. We reproduced the same association as we reported previously between LRP5 V667M and LS BMD (p = 0.015) but not with FN BMD (p = 0.254). The combined data from the two populations indicate an effect size of 0.28SD for LS BMD (p = 0.00048) and an effect size of 0.26 SD for FN BMD (p = 0.00037). In contrast, the association we reported earlier between ESRRA repeats and LS BMD was not replicated in the sample from Toronto (p = 0.645). The association between LRP5 V667M and LS BMD is confirmed but not that between ESRRA repeats and LS BMD. This result indicates that it is imperative to validate any positive association in an independent sample.

  11. On the performance of laser-induced breakdown spectroscopy for direct determination of trace metals in lubricating oils

    NASA Astrophysics Data System (ADS)

    Zheng, Lijuan; Cao, Fan; Xiu, Junshan; Bai, Xueshi; Motto-Ros, Vincent; Gilon, Nicole; Zeng, Heping; Yu, Jin

    2014-09-01

    Laser-induced breakdown spectroscopy (LIBS) provides a technique to directly determine metals in viscous liquids and especially in lubricating oils. A specific laser ablation configuration of a thin layer of oil applied on the surface of a pure aluminum target was used to evaluate the analytical figures of merit of LIBS for elemental analysis of lubricating oils. Among the analyzed oils, there were a certified 75cSt blank mineral oil, 8 virgin lubricating oils (synthetic, semi-synthetic, or mineral and of 2 different manufacturers), 5 used oils (corresponding to 5 among the 8 virgin oils), and a cooking oil. The certified blank oil and 4 virgin lubricating oils were spiked with metallo-organic standards to obtain laboratory reference samples with different oil matrix. We first established calibration curves for 3 elements, Fe, Cr, Ni, with the 5 sets of laboratory reference samples in order to evaluate the matrix effect by the comparison among the different oils. Our results show that generalized calibration curves can be built for the 3 analyzed elements by merging the measured line intensities of the 5 sets of spiked oil samples. Such merged calibration curves with good correlation of the merged data are only possible if no significant matrix effect affects the measurements of the different oils. In the second step, we spiked the remaining 4 virgin oils and the cooking oils with Fe, Cr and Ni. The accuracy and the precision of the concentration determination in these prepared oils were then evaluated using the generalized calibration curves. The concentrations of metallic elements in the 5 used lubricating oils were finally determined.

  12. Initial experimental demonstration of the principles of a xenon gas shield designed to protect optical components from soft x-ray induced opacity (blanking) in high energy density experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swadling, G. F.; Ross, J. S.; Manha, D.

    The design principles of a xenon gas shield device that is intended to protect optical components from x-ray induced opacity (“x-ray blanking”) have been experimentally demonstrated at the OMEGA-60 Laser Facility at the Laboratory for Laser Energetics, University of Rochester. A volume of xenon gas placed in front of an optical component absorbs the incoming soft x-ray radiation but transmits optical and ultra-violet radiation. The time-resolved optical (532 nm) transmission of samples was recorded as they were exposed to soft x-rays produced by a gold sphere source (1.5 kJ sr $-$1, 250–300 eV). Blanking of fused silica (SiO 2) wasmore » measured to occur over a range of time-integrated soft x-ray (<3 keV) fluence from ~0.2–2.5 J cm $-$2. A shield test device consisting of a 30 nm silicon nitride (Si 3N 4) and a 10 cm long volume of 0.04 bar xenon gas succeeded in delaying loss of transmission through a magnesium fluoride sample; optical transmission was observed over a longer period than for the unprotected sample. It is hoped that the design of this x-ray shield can be scaled in order to produce a shield device for the National Ignition Facility optical Thomson scattering collection telescope, in order to allow measurements of hohlraum plasma conditions produced in inertial confinement fusion experiments. Finally, if successful, it will also have applications in many other high energy density experiments where optical and ultra-violet measurements are desirable.« less

  13. Initial experimental demonstration of the principles of a xenon gas shield designed to protect optical components from soft x-ray induced opacity (blanking) in high energy density experiments

    DOE PAGES

    Swadling, G. F.; Ross, J. S.; Manha, D.; ...

    2017-03-16

    The design principles of a xenon gas shield device that is intended to protect optical components from x-ray induced opacity (“x-ray blanking”) have been experimentally demonstrated at the OMEGA-60 Laser Facility at the Laboratory for Laser Energetics, University of Rochester. A volume of xenon gas placed in front of an optical component absorbs the incoming soft x-ray radiation but transmits optical and ultra-violet radiation. The time-resolved optical (532 nm) transmission of samples was recorded as they were exposed to soft x-rays produced by a gold sphere source (1.5 kJ sr $-$1, 250–300 eV). Blanking of fused silica (SiO 2) wasmore » measured to occur over a range of time-integrated soft x-ray (<3 keV) fluence from ~0.2–2.5 J cm $-$2. A shield test device consisting of a 30 nm silicon nitride (Si 3N 4) and a 10 cm long volume of 0.04 bar xenon gas succeeded in delaying loss of transmission through a magnesium fluoride sample; optical transmission was observed over a longer period than for the unprotected sample. It is hoped that the design of this x-ray shield can be scaled in order to produce a shield device for the National Ignition Facility optical Thomson scattering collection telescope, in order to allow measurements of hohlraum plasma conditions produced in inertial confinement fusion experiments. Finally, if successful, it will also have applications in many other high energy density experiments where optical and ultra-violet measurements are desirable.« less

  14. The CAMELS data set: catchment attributes and meteorology for large-sample studies

    NASA Astrophysics Data System (ADS)

    Addor, Nans; Newman, Andrew J.; Mizukami, Naoki; Clark, Martyn P.

    2017-10-01

    We present a new data set of attributes for 671 catchments in the contiguous United States (CONUS) minimally impacted by human activities. This complements the daily time series of meteorological forcing and streamflow provided by Newman et al. (2015b). To produce this extension, we synthesized diverse and complementary data sets to describe six main classes of attributes at the catchment scale: topography, climate, streamflow, land cover, soil, and geology. The spatial variations among basins over the CONUS are discussed and compared using a series of maps. The large number of catchments, combined with the diversity of the attributes we extracted, makes this new data set well suited for large-sample studies and comparative hydrology. In comparison to the similar Model Parameter Estimation Experiment (MOPEX) data set, this data set relies on more recent data, it covers a wider range of attributes, and its catchments are more evenly distributed across the CONUS. This study also involves assessments of the limitations of the source data sets used to compute catchment attributes, as well as detailed descriptions of how the attributes were computed. The hydrometeorological time series provided by Newman et al. (2015b, https://doi.org/10.5065/D6MW2F4D) together with the catchment attributes introduced in this paper (https://doi.org/10.5065/D6G73C3Q) constitute the freely available CAMELS data set, which stands for Catchment Attributes and MEteorology for Large-sample Studies.

  15. Extraction of Solar Wind Nitrogen and Noble Gases From the Genesis Gold Foil Collector

    NASA Astrophysics Data System (ADS)

    Schlutter, D. J.; Pepin, R. O.

    2005-12-01

    The Genesis gold foil is a bulk solar wind collector, integrating fluences from all three of the wind regimes. Pyrolytic extraction of small foil samples at Minnesota yielded He fluences, corrected for backscatter, in good agreement with measurements by on-board spacecraft instruments, and He/Ne elemental ratios close to those implanted in collector foils deployed on the lunar surface during the Apollo missions. Isotopic distributions of He, Ne and Ar are under study. Pyrolysis to temperatures above the gold melting point generates nitrogen blanks large enough to obscure the solar-wind nitrogen component. An alternative technique for nitrogen and noble gas extraction, by room-temperature amalgamation of the gold foil surface, will be discussed. Ne and Ar releases in preliminary tests of this technique on small foil samples were close to 100% of the amounts expected from the high-temperature pyrolysis yields, indicating that amalgamation quantitatively liberates gases from several hundred angstroms deep in the gold, beyond the implantation depth of most of the solar wind. Present work is focused on two problems currently interfering with accurate nitrogen measurements at the required picogram to sub-picogram levels: a higher than expected blank likely due to tiny air bubbles rolled into the gold sheet during fabrication, and the presence of a refractory hydrocarbon film on Genesis collector surfaces (the "brown stain") that, if left in place on the foil, shields the underlying gold from mercury attack. We have found, however, that the film is efficiently removed within tens of seconds by oxygen plasma ashing. Potential nitrogen contaminants introduced during the crash of the sample return canister are inert in amalgamation, and so are not hazards to the measurements.

  16. Groundwater-quality data in the Bear Valley and Selected Hard Rock Areas study unit, 2010: Results from the California GAMA Program

    USGS Publications Warehouse

    Mathany, Timothy M.; Belitz, Kenneth

    2013-01-01

    Groundwater quality in the 112-square-mile Bear Valley and Selected Hard Rock Areas (BEAR) study unit was investigated by the U.S. Geological Survey (USGS) from April to August 2010, as part of the California State Water Resources Control Board (SWRCB) Groundwater Ambient Monitoring and Assessment (GAMA) Program’s Priority Basin Project (PBP). The GAMA-PBP was developed in response to the California Groundwater Quality Monitoring Act of 2001 and is being conducted in collaboration with the SWRCB and Lawrence Livermore National Laboratory (LLNL). The BEAR study unit was the thirty-first study unit to be sampled as part of the GAMA-PBP. The GAMA Bear Valley and Selected Hard Rock Areas study was designed to provide a spatially unbiased assessment of untreated-groundwater quality in the primary aquifer system and to facilitate statistically consistent comparisons of untreated groundwater quality throughout California. The primary aquifer system is defined as the zones corresponding to the perforation intervals of wells listed in the California Department of Public Health (CDPH) database for the BEAR study unit. Groundwater quality in the primary aquifer system may differ from the quality in the shallow or deep water-bearing zones; shallow groundwater may be more vulnerable to surficial contamination. In the BEAR study unit, groundwater samples were collected from two study areas (Bear Valley and Selected Hard Rock Areas) in San Bernardino County. Of the 38 sampling sites, 27 were selected by using a spatially distributed, randomized grid-based method to provide statistical representation of the primary aquifer system in the study unit (grid sites), and the remaining 11 sites were selected to aid in the understanding of the potential groundwater-quality issues associated with septic tank use and with ski areas in the study unit (understanding sites). The groundwater samples were analyzed for organic constituents (volatile organic compounds [VOCs], pesticides and pesticide degradates, pharmaceutical compounds, and wastewater indicator compounds [WICs]), constituents of special interest (perchlorate, N-nitrosodimethylamine [NDMA], and 1,2,3-trichloropropane [1,2,3-TCP]), and inorganic constituents (trace elements, nutrients, dissolved organic carbon [DOC], major and minor ions, silica, total dissolved solids [TDS], alkalinity, and arsenic and iron species), and uranium and other radioactive constituents (radon-222 and activities of tritium and carbon-14). Isotopic tracers (of hydrogen and oxygen in water, of nitrogen and oxygen in dissolved nitrate, of dissolved boron, isotopic ratios of strontium in water, and of carbon in dissolved inorganic carbon) and dissolved noble gases (argon, helium-4, krypton, neon, and xenon) were measured to help identify the sources and ages of sampled groundwater. In total, groundwater samples were analyzed for 289 unique constituents and 8 water-quality indicators in the BEAR study unit. Quality-control samples (blanks, replicate pairs, or matrix spikes) were collected at 13 percent of the sites in the BEAR study unit, and the results for these samples were used to evaluate the quality of the data from the groundwater samples. Blank samples rarely contained detectable concentrations of any constituent, indicating that contamination from sample collection or analysis was not a significant source of bias in the data for the groundwater samples. Replicate pair samples all were within acceptable limits of variability. Matrix-spike sample recoveries were within the acceptable range (70 to 130 percent) for approximately 84 percent of the compounds. This study did not evaluate the quality of water delivered to consumers. After withdrawal, groundwater typically is treated, disinfected, and (or) blended with other waters to maintain water quality. Regulatory benchmarks apply to water that is delivered to the consumer, not to untreated groundwater. However, to provide some context for the results, concentrations of constituents measured in the untreated groundwater were compared with regulatory and non-regulatory health-based benchmarks established by the U.S. Environmental Protection Agency (USEPA) and CDPH, and to non-health-based benchmarks established for aesthetic concerns by CDPH. Comparisons between data collected for this study and benchmarks for drinking water are for illustrative purposes only and are not indicative of compliance or non-compliance with those benchmarks. All concentrations of organic and special-interest constituents from grid sites sampled in the BEAR study unit were less than health-based benchmarks. In total, VOCs were detected in 17 of the 27 grid sites sampled (approximately 63 percent), pesticides and pesticide degradates were detected in 4 grid sites (approximately 15 percent), and perchlorate was detected in 21 grid sites (approximately 78 percent). Inorganic constituents (trace elements, major and minor ions, nutrients, and uranium and other radioactive constituents) were sampled for at 27 grid sites; most concentrations were less than health-based benchmarks. Exceptions include one detection of arsenic greater than the USEPA maximum contaminant level (MCL-US) of 10 micrograms per liter (μg/L), three detections of uranium greater than the MCL-US of 30 μg/L, nine detections of radon-222 greater than the proposed MCL-US of 4,000 picocuries per liter (pCi/L), and one detection of fluoride greater than the CDPH maximum contaminant level (MCL-CA) of 2 milligrams per liter. Concentrations of inorganic constituents with non-health-based benchmarks (iron, manganese, chloride, and TDS) were less than the CDPH secondary maximum contaminant level (SMCL-CA) in most grid sites. Exceptions include two detections of iron greater than the SMCL-CA of 300 μg/L and one detection of manganese greater than the SMCL-CA of 50 μg/L.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adams, Wade C.

    Oak Ridge Institute for Science and Education (ORISE) personnel visited the United Nuclear Corporation (UNC) Naval Products site on three separate occasions during the months of October and November 2011. The purpose of these visits was to conduct confirmatory surveys of soils associated with the Argyle Street sewer line that was being removed. Soil samples were collected from six different, judgmentally determined locations in the Argyle Street sewer trench. In addition to the six soil samples collected by ORISE, four replicate soil samples were collected by Cabrera Services, Inc. (CSI) for analysis by the ORISE laboratory. Replicate samples S0010 andmore » S0011 were final status survey (FSS) bias samples; S0012 was an FSS systematic sample; and S0015 was a waste characterization sample. Six soil samples were also collected for background determination. Uranium-235 and uranium-238 concentrations were determined via gamma spectroscopy; the spectra were also reviewed for other identifiable photopeaks. Radionuclide concentrations for these soil samples are provided. In addition to the replicate samples and the samples collected by ORISE, CSI submitted three soil samples for inter-laboratory comparison analyses. One sample was from the background reference area, one was from waste characterization efforts (material inside the sewer line), and one was a FSS sample. The inter-laboratory comparison analyses results between ORISE and CSI were in agreement, except for one sample collected in the reference area. Smear results For Argyle Street sewer pipes are tabulated.« less

  18. Bis-aptazyme sensors for hepatitis C virus replicase and helicase without blank signal

    PubMed Central

    Cho, Suhyung; Kim, Ji-Eun; Lee, Bo-Rahm; Kim, June-Hyung; Kim, Byung-Gee

    2005-01-01

    The fusion molecule (i.e. aptazyme) of aptamer and hammerhead ribozyme was developed as in situ sensor. Previously, the hammerhead ribozyme conjugated with aptamer through its stem II module showed a significant blank signal by self-cleavage. To reduce or remove its self-cleavage activity in the absence of target molecule, rational designs were attempted by reducing the binding affinity of the aptazyme to its RNA substrate, while maintaining the ribonuclease activity of the aptazyme. Interestingly, the bis-aptazymes which comprise the two aptamer-binding sites at both stem I and stem III of the hammerhead ribozyme showed very low blank signals, and their ratios of reaction rate constants, i.e. signal to noise ratios, were several tens to hundred times higher than those of the stem II-conjugated bis-aptazymes. The reduction in the blank signals seems to be caused by a higher dissociation constant between the main strand of the bis-aptazyme and its substrate arising from multi-point base-pairing of the bis-aptazymes. The bis-aptazymes for HCV replicase and helicase showed high selectivity against other proteins, and a linear relationship existed between their ribozyme activities and the target concentrations. In addition, a bis-aptazyme of dual functions was designed by inserting both aptamers for HCV replicase and helicase into the stem I and stem III of hammerhead ribozyme, respectively, and it also showed greater sensitivity and specificity for both proteins without blank signal. PMID:16314308

  19. Dogs can discriminate human smiling faces from blank expressions.

    PubMed

    Nagasawa, Miho; Murai, Kensuke; Mogi, Kazutaka; Kikusui, Takefumi

    2011-07-01

    Dogs have a unique ability to understand visual cues from humans. We investigated whether dogs can discriminate between human facial expressions. Photographs of human faces were used to test nine pet dogs in two-choice discrimination tasks. The training phases involved each dog learning to discriminate between a set of photographs of their owner's smiling and blank face. Of the nine dogs, five fulfilled these criteria and were selected for test sessions. In the test phase, 10 sets of photographs of the owner's smiling and blank face, which had previously not been seen by the dog, were presented. The dogs selected the owner's smiling face significantly more often than expected by chance. In subsequent tests, 10 sets of smiling and blank face photographs of 20 persons unfamiliar to the dogs were presented (10 males and 10 females). There was no statistical difference between the accuracy in the case of the owners and that in the case of unfamiliar persons with the same gender as the owner. However, the accuracy was significantly lower in the case of unfamiliar persons of the opposite gender to that of the owner, than with the owners themselves. These results suggest that dogs can learn to discriminate human smiling faces from blank faces by looking at photographs. Although it remains unclear whether dogs have human-like systems for visual processing of human facial expressions, the ability to learn to discriminate human facial expressions may have helped dogs adapt to human society.

  20. Radial-rotation profile forming: A new processing technology of incremental sheet metal forming

    NASA Astrophysics Data System (ADS)

    Laue, Robert; Härtel, Sebastian; Awiszus, Birgit

    2018-05-01

    Incremental forming processes (i.e., spinning) of sheet metal blanks into cylindrical cups are suitable for lower lot sizes. The produced cups were frequently used as preforms to produce workpieces in further forming steps with additional functions like profiled hollow parts [1]. The incremental forming process radial-rotation profile forming has been developed to enable the production of profiled hollow parts with low sheet thinning and good geometrical accuracy. The two principal forming steps are the production of the preform by rotational swing-folding [2] and the subsequent radial profiling of the hollow part in one clamping position. The rotational swing-folding process is based on a combination of conventional spinning and swing-folding. Therefore, a round blank rotates on a profiled mandrel and due to the swinging of a cylindrical forming tool, the blank is formed to a cup with low sheet thinning. In addition, thickening results at the edge of the blank and wrinkling occurs. However, the wrinkles are formed into the indentation of the profiled mandrel and can be reshaped as an advantage in the second process step, the radial profiling. Due to the rotation and continuous radial feed of a profiled forming tool to the profiled mandrel, the axial profile is formed in the second process step. Because of the minor relative movement in axial direction between tool and blank, low sheet thinning occurs. This is an advantage of the principle of the process.

  1. Concentrations of the Allelochemical (+/-)-catechin IN Centaurea maculosa soils.

    PubMed

    Perry, Laura G; Thelen, Giles C; Ridenour, Wendy M; Callaway, Ragan M; Paschke, Mark W; Vivanco, Jorge M

    2007-12-01

    The phytotoxin (+/-)-catechin has been proposed to mediate invasion and autoinhibition by the Eurasian plant Centaurea maculosa (spotted knapweed). The importance of (+/-)-catechin to C. maculosa ecology depends in part on whether sufficient catechin concentrations occur at appropriate times and locations within C. maculosa soil to influence neighboring plants. Previous research on catechin in C. maculosa soils has yielded conflicting results, with some studies finding high soil catechin concentrations and other, more recent studies finding little or no catechin in field soils. Here, we report the most extensive study of soil catechin concentrations to date. We examined soil catechin concentrations in 402 samples from 11 C. maculosa sites in North America sampled in consecutive months over 1 yr, excluding winter months. One site was sampled on seven dates, another was sampled twice, and the remaining nine sites were each sampled once on a range of sampling dates. Methods used were similar to those with which we previously measured high soil catechin concentrations. We detected catechin only in the site that was sampled on seven dates and only on one sampling date in that site (May 16 2006), but in all samples collected on that date. The mean soil catechin concentration on that date was 0.65 +/- 0.45 (SD) mg g(-1), comparable to previously reported high concentrations. There are a number of possible explanations for the infrequency with which we detected soil catechin in this work compared to previous studies. Differences in results could reflect spatial and temporal variation in catechin exudation or degradation, as we examined different sites in a different year from most previous studies. Also, large quantities of catechin were detected in blanks for two sampling periods in the present study, leading us to discard those data. This contamination suggests that previous reports of high catechin concentrations that did not include blanks should be viewed with caution. Our results suggest that pure catechin is only rarely present in C. maculosa bulk soils. Thus, although catechin may play a role in C. maculosa invasion, the infrequency of soil catechin that we determined in this study suggests that we cannot be as certain of its role as previous reports of high soil catechin concentrations suggested.

  2. Characterization and Validation of the LT-SYS Copper Assay on a Roche Cobas 8000 c502 Analyzer.

    PubMed

    Kraus, F Bernhard; Mischereit, Marlies; Eller, Christoph; Ludwig-Kraus, Beatrice

    2017-02-01

    Validation of the LT-SYS quantitative in vitro copper assay on a Roche Cobas 8000 c502 analyzer and comparison with a BIOMED assay on a Roche Cobas Mira analyzer. Imprecision and bias were quantified at different concentration levels (serum and plasma) over a 20-day period. Linearity was assessed covering a range from 4.08 µmol/L to 33.8 µmol/L. Limit of blank (LoB) and limit of detection (LoD) were established based on a total of 120 blank and low-level samples. The method comparison was based on 58 plasma samples. Within-run imprecision ranged from 0.7% to 1.2% and within-laboratory imprecision from 1.4% to 3.3%. Relative bias for the 2 serum pools with known target values was less than 2.5%. The assay did not deviate from linearity over the tested measuring range. LoB and LoD were 0.12 µmol/L and 0.23 µmol/L, respectively. The method comparison revealed an average deviation of 11.5% (2.016 µmol/L), and the linear regression fit was y = 1.464 + 0.795x. The LT-SYS copper assay characterized in this study showed a fully acceptable performance with good degrees of imprecision and bias, no deviation from linearity in the relevant measuring rangem, and very low LoB and LoD. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Groundwater-quality data in the Monterey–Salinas shallow aquifer study unit, 2013: Results from the California GAMA Program

    USGS Publications Warehouse

    Goldrath, Dara A.; Kulongoski, Justin T.; Davis, Tracy A.

    2016-09-01

    Groundwater quality in the 3,016-square-mile Monterey–Salinas Shallow Aquifer study unit was investigated by the U.S. Geological Survey (USGS) from October 2012 to May 2013 as part of the California State Water Resources Control Board Groundwater Ambient Monitoring and Assessment (GAMA) Program’s Priority Basin Project. The GAMA Monterey–Salinas Shallow Aquifer study was designed to provide a spatially unbiased assessment of untreated-groundwater quality in the shallow-aquifer systems in parts of Monterey and San Luis Obispo Counties and to facilitate statistically consistent comparisons of untreated-groundwater quality throughout California. The shallow-aquifer system in the Monterey–Salinas Shallow Aquifer study unit was defined as those parts of the aquifer system shallower than the perforated depth intervals of public-supply wells, which generally corresponds to the part of the aquifer system used by domestic wells. Groundwater quality in the shallow aquifers can differ from the quality in the deeper water-bearing zones; shallow groundwater can be more vulnerable to surficial contamination.Samples were collected from 170 sites that were selected by using a spatially distributed, randomized grid-based method. The study unit was divided into 4 study areas, each study area was divided into grid cells, and 1 well was sampled in each of the 100 grid cells (grid wells). The grid wells were domestic wells or wells with screen depths similar to those in nearby domestic wells. A greater spatial density of data was achieved in 2 of the study areas by dividing grid cells in those study areas into subcells, and in 70 subcells, samples were collected from exterior faucets at sites where there were domestic wells or wells with screen depths similar to those in nearby domestic wells (shallow-well tap sites).Field water-quality indicators (dissolved oxygen, water temperature, pH, and specific conductance) were measured, and samples for analysis of inorganic constituents (trace elements, nutrients, major and minor ions, silica, total dissolved solids, and alkalinity) were collected at all 170 sites. In addition to these constituents, the samples from grid wells were analyzed for organic constituents (volatile organic compounds, pesticides and pesticide degradates), constituents of special interest (perchlorate and N-nitrosodimethylamine, or NDMA), radioactive constituents (radon-222 and gross-alpha and gross-beta radioactivity), and geochemical and age-dating tracers (stable isotopes of carbon in dissolved inorganic carbon, carbon-14 abundances, stable isotopes of hydrogen and oxygen in water, and tritium activities).Three types of quality-control samples (blanks, replicates, and matrix spikes) were collected at up to 11 percent of the wells in the Monterey–Salinas Shallow Aquifer study unit, and the results for these samples were used to evaluate the quality of the data from the groundwater samples. With the exception of trace elements, blanks rarely contained detectable concentrations of any constituent, indicating that contamination from sample-collection procedures was not a significant source of bias in the data for the groundwater samples. Low concentrations of some trace elements were detected in blanks; therefore, the data were re-censored at higher reporting levels. Replicate samples generally were within the limits of acceptable analytical reproducibility. The median values of matrix-spike recoveries were within the acceptable range (70 to 130 percent) for the volatile organic compounds (VOCs) and N-nitrosodimethylamine (NDMA), but were only approximately 64 percent for pesticides and pesticide degradates.The sample-collection protocols used in this study were designed to obtain representative samples of groundwater. The quality of groundwater can differ from the quality of drinking water because water chemistry can change as a result of contact with plumbing systems or the atmosphere; because of treatment, disinfection, or blending with water from other sources; or some combination of these. Water quality in domestic wells is not regulated in California, however, to provide context for the water-quality data presented in this report, results were compared to benchmarks established for drinking-water quality. The primary comparison benchmarks were maximum contaminant levels established by the U.S. Environmental Protection Agency and the State of California (MCL-US and MCL-CA, respectively). Non-regulatory benchmarks were used for constituents without maximum contaminant levels (MCLs), including Health Based Screening Levels (HBSLs) developed by the USGS and State of California secondary maximum contaminant levels (SMCL-CA) and notification levels. Most constituents detected in samples from the Monterey–Salinas Shallow Aquifer study unit had concentrations less than their respective benchmarks.Of the 148 organic constituents analyzed in the 100 grid-well samples, 38 were detected, and all concentrations were less than the benchmarks. Volatile organic compounds were detected in 26 of the grid wells, and pesticides and pesticide degradates were detected in 28 grid wells. The special-interest constituent NDMA was detected above the HBSL in three samples, one of which also had a perchlorate concentration greater than the MCL-CA.Of the inorganic constituents, 6 were detected at concentrations above their respective MCL benchmarks in grid-well samples: arsenic (5 grid wells above the MCL of 10 micrograms per liter, μg/L), selenium (3 grid wells, MCL of 50 μg/L), uranium (4 grid wells, MCL of 30 μg/L), nitrate (16 grid wells, MCL of 10 milligrams per liter, mg/L), adjusted gross alpha particle activity (10 grid wells, MCL of 15 picocuries per liter, pCi/L), and gross beta particle activity (1 grid well, MCL of 50 pCi/L). An additional 4 inorganic constituents were detected at concentrations above their respective HBSL benchmarks in grid-well samples: boron (1 grid well above the HBSL of 6,000 μg/L), manganese (8 grid wells, HBSL of 300 μg/L), molybdenum (6 grid wells, HBSL of 40 μg/L), and strontium (6 grid wells, HBSL of 4,000 μg/L). Of the inorganic constituents, 4 were detected at concentrations above their non-health based SMCL benchmarks in grid-well samples: iron (9 grid wells above the SMCL of 300 μg/L), chloride (7 grid wells, SMCL of 500 mg/L), sulfate (14 grid wells, SMCL of 500 mg/L), and total dissolved solids (27 grid wells, SMCL of 1,000 mg/L).Of the inorganic constituents analyzed in the 70 shallow-well tap sites, 10 were detected at concentrations above the benchmarks. Of the inorganic constituents, 3 were detected at concentrations above their respective MCL benchmarks in shallow-well tap sites: arsenic (2 shallow-well tap sites above the MCL of 10 μg/L), uranium (2 shallow-well tap sites, MCL of 30 μg/L), and nitrate (24 shallow-well tap sites, MCL of 10 mg/L). An additional 3 inorganic constituents were detected above their respective HBSL benchmarks in shallow-well tap sites: manganese (4 shallow-well tap sites above the HBSL of 300 μg/L), molybdenum (4 shallow-well tap sites, HBSL of 40 μg/L), and zinc (2 shallow-well tap sites, HBSL of 2,000 μg/L). Of the inorganic constituents, 4 were detected at concentrations above their non-health based SMCL benchmarks in shallow-well tap sites: iron (6 shallow-well tap sites above the SMCL of 300 μg/L), chloride (1 shallow-well tap site, SMCL of 500 mg/L), sulfate (9 shallow-well tap sites, SMCL of 500 mg/L), and total dissolved solids (15 shallow-well tap sites, SMCL of 1,000 mg/L).

  4. EUVL Mask Blank Repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barty, A; Mirkarimi, P; Stearns, D G

    2002-05-22

    EUV mask blanks are fabricated by depositing a reflective Mo/Si multilayer film onto super-polished substrates. Small defects in this thin film coating can significantly alter the reflected field and introduce defects in the printed image. Ideally one would want to produce defect-free mask blanks; however, this may be very difficult to achieve in practice. One practical way to increase the yield of mask blanks is to effectively repair multilayer defects, and to this effect they present two complementary defect repair strategies for use on multilayer-coated EUVL mask blanks. A defect is any area on the mask which causes unwanted variationsmore » in EUV dose in the aerial image obtained in a printing tool, and defect repair is correspondingly defined as any strategy that renders a defect unprintable during exposure. The term defect mitigation can be adopted to describe any strategy which renders a critical defect non-critical when printed, and in this regard a non-critical defect is one that does not adversely affect device function. Defects in the patterned absorber layer consist of regions where metal, typically chrome, is unintentionally added or removed from the pattern leading to errors in the reflected field. There currently exists a mature technology based on ion beam milling and ion beam assisted deposition for repairing defects in the absorber layer of transmission lithography masks, and it is reasonable to expect that this technology will be extended to the repair of absorber defects in EUVL masks. However, techniques designed for the repair of absorber layers can not be directly applied to the repair of defects in the mask blank, and in particular the multilayer film. In this paper they present for the first time a new technique for the repair of amplitude defects as well as recent results on the repair of phase defects.« less

  5. Carbon-isotopic analysis of individual pollen grains from C 3 and C 4 grasses using a spooling-wire microcombustion interface

    NASA Astrophysics Data System (ADS)

    Nelson, David M.; Hu, Feng Sheng; Mikucki, Jill A.; Tian, Jian; Pearson, Ann

    2007-08-01

    Pollen grains from grasses using the C 3 and C 4 photosynthetic pathways have distinct ranges of δ 13C values that may be used to estimate their relative abundance in paleorecords. We evaluated a spooling-wire microcombustion device interfaced with an isotope-ratio mass spectrometer (SWiM-IRMS) for δ 13C analysis of individual grass-pollen grains. Pollen from four C 3 and four C 4 grass species was isolated through micromanipulation and analyzed as single grains suspended in water. A carbon yield greater than the 2 σ range of the carbon content of blanks containing only water was used to distinguish samples containing pollen ("pollen present") from those not containing pollen. This criterion resulted in the exclusion of ˜45% of the 946 samples applied to the wire. The average δ 13C values (±1 σ) of the remaining samples were -26.9‰ (±6.3‰) and -11.5‰ (±9.6‰) for C 3 grasses and C 4 grasses, respectively, after blank-correcting the δ 13C data. These results suggest that the SWiM-IRMS system can be used to distinguish C 3 from C 4 grass pollen. The high variability in measured δ 13C values is likely caused by a combination of factors. These include natural isotopic variability among individual pollen grains; the relatively poor precision that can be obtained when determining δ 13C values of such small samples; and the uncertainty in the magnitude, isotopic composition, and stability of the analytical blank. Nonetheless, high percentages of individual pollen grains were correctly classified as being of either C 3 or C 4 origin. On average, 90% (range = 78-100%) of pollen grains from C 3 grasses had δ 13C values more negative than the cutoff threshold of -19.2‰; while 84% (range = 77-90%) of pollen grains from C 4 grasses had δ 13C values more positive than -19.2‰. Compared with analysis using an elemental analyzer interfaced with an IRMS (EA-IRMS), the number of pollen grains required for δ 13C-based evaluation of C 3/C 4 grass composition is many times lower with the SWiM-IRMS. Additionally, δ 13C data from the SWiM-IRMS does not need to be incorporated into a mixing model to derive estimates of the abundance of C 3 and C 4 grass pollen. Carbon-isotopic analysis of individual grass-pollen grains using the SWiM-IRMS system may help improve our understanding of the evolutionary and ecological significance of grass taxa in the paleorecord.

  6. Evaluation of the reproducibility of amplicon sequencing with Illumina MiSeq platform

    PubMed Central

    Van Nostrand, Joy D.; Ning, Daliang; Sun, Bo; Xue, Kai; Liu, Feifei; Deng, Ye; Liang, Yuting; Zhou, Jizhong

    2017-01-01

    Illumina’s MiSeq has become the dominant platform for gene amplicon sequencing in microbial ecology studies; however, various technical concerns, such as reproducibility, still exist. To assess reproducibility, 16S rRNA gene amplicons from 18 soil samples of a reciprocal transplantation experiment were sequenced on an Illumina MiSeq. The V4 region of 16S rRNA gene from each sample was sequenced in triplicate with each replicate having a unique barcode. The average OTU overlap, without considering sequence abundance, at a rarefaction level of 10,323 sequences was 33.4±2.1% and 20.2±1.7% between two and among three technical replicates, respectively. When OTU sequence abundance was considered, the average sequence abundance weighted OTU overlap was 85.6±1.6% and 81.2±2.1% for two and three replicates, respectively. Removing singletons significantly increased the overlap for both (~1–3%, p<0.001). Increasing the sequencing depth to 160,000 reads by deep sequencing increased OTU overlap both when sequence abundance was considered (95%) and when not (44%). However, if singletons were not removed the overlap between two technical replicates (not considering sequence abundance) plateaus at 39% with 30,000 sequences. Diversity measures were not affected by the low overlap as α-diversities were similar among technical replicates while β-diversities (Bray-Curtis) were much smaller among technical replicates than among treatment replicates (e.g., 0.269 vs. 0.374). Higher diversity coverage, but lower OTU overlap, was observed when replicates were sequenced in separate runs. Detrended correspondence analysis indicated that while there was considerable variation among technical replicates, the reproducibility was sufficient for detecting treatment effects for the samples examined. These results suggest that although there is variation among technical replicates, amplicon sequencing on MiSeq is useful for analyzing microbial community structure if used appropriately and with caution. For example, including technical replicates, removing spurious sequences and unrepresentative OTUs, using a clustering method with a high stringency for OTU generation, estimating treatment effects at higher taxonomic levels, and adapting the unique molecular identifier (UMI) and other newly developed methods to lower PCR and sequencing error and to identify true low abundance rare species all can increase reproducibility. PMID:28453559

  7. Evaluation of the reproducibility of amplicon sequencing with Illumina MiSeq platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wen, Chongqing; Wu, Liyou; Qin, Yujia

    Illumina's MiSeq has become the dominant platform for gene amplicon sequencing in microbial ecology studies; however, various technical concerns, such as reproducibility, still exist. To assess reproducibility, 16S rRNA gene amplicons from 18 soil samples of a reciprocal transplantation experiment were sequenced on an Illumina MiSeq. The V4 region of 16S rRNA gene from each sample was sequenced in triplicate with each replicate having a unique barcode. The average OTU overlap, without considering sequence abundance, at a rarefaction level of 10,323 sequences was 33.4±2.1% and 20.2±1.7% between two and among three technical replicates, respectively. When OTU sequence abundance was considered,more » the average sequence abundance weighted OTU overlap was 85.6±1.6% and 81.2±2.1% for two and three replicates, respectively. Removing singletons significantly increased the overlap for both (~1-3%, p<0.001). Increasing the sequencing depth to 160,000 reads by deep sequencing increased OTU overlap both when sequence abundance was considered (95%) and when not (44%). However, if singletons were not removed the overlap between two technical replicates (not considering sequence abundance) plateaus at 39% with 30,000 sequences. Diversity measures were not affected by the low overlap as α-diversities were similar among technical replicates while β-diversities (Bray-Curtis) were much smaller among technical replicates than among treatment replicates (e.g., 0.269 vs. 0.374). Higher diversity coverage, but lower OTU overlap, was observed when replicates were sequenced in separate runs. Detrended correspondence analysis indicated that while there was considerable variation among technical replicates, the reproducibility was sufficient for detecting treatment effects for the samples examined. These results suggest that although there is variation among technical replicates, amplicon sequencing on MiSeq is useful for analyzing microbial community structure if used appropriately and with caution. For example, including technical replicates, removing spurious sequences and unrepresentative OTUs, using a clustering method with a high stringency for OTU generation, estimating treatment effects at higher taxonomic levels, and adapting the unique molecular identifier (UMI) and other newly developed methods to lower PCR and sequencing error and to identify true low abundance rare species all can increase reproducibility.« less

  8. Evaluation of the reproducibility of amplicon sequencing with Illumina MiSeq platform

    DOE PAGES

    Wen, Chongqing; Wu, Liyou; Qin, Yujia; ...

    2017-04-28

    Illumina's MiSeq has become the dominant platform for gene amplicon sequencing in microbial ecology studies; however, various technical concerns, such as reproducibility, still exist. To assess reproducibility, 16S rRNA gene amplicons from 18 soil samples of a reciprocal transplantation experiment were sequenced on an Illumina MiSeq. The V4 region of 16S rRNA gene from each sample was sequenced in triplicate with each replicate having a unique barcode. The average OTU overlap, without considering sequence abundance, at a rarefaction level of 10,323 sequences was 33.4±2.1% and 20.2±1.7% between two and among three technical replicates, respectively. When OTU sequence abundance was considered,more » the average sequence abundance weighted OTU overlap was 85.6±1.6% and 81.2±2.1% for two and three replicates, respectively. Removing singletons significantly increased the overlap for both (~1-3%, p<0.001). Increasing the sequencing depth to 160,000 reads by deep sequencing increased OTU overlap both when sequence abundance was considered (95%) and when not (44%). However, if singletons were not removed the overlap between two technical replicates (not considering sequence abundance) plateaus at 39% with 30,000 sequences. Diversity measures were not affected by the low overlap as α-diversities were similar among technical replicates while β-diversities (Bray-Curtis) were much smaller among technical replicates than among treatment replicates (e.g., 0.269 vs. 0.374). Higher diversity coverage, but lower OTU overlap, was observed when replicates were sequenced in separate runs. Detrended correspondence analysis indicated that while there was considerable variation among technical replicates, the reproducibility was sufficient for detecting treatment effects for the samples examined. These results suggest that although there is variation among technical replicates, amplicon sequencing on MiSeq is useful for analyzing microbial community structure if used appropriately and with caution. For example, including technical replicates, removing spurious sequences and unrepresentative OTUs, using a clustering method with a high stringency for OTU generation, estimating treatment effects at higher taxonomic levels, and adapting the unique molecular identifier (UMI) and other newly developed methods to lower PCR and sequencing error and to identify true low abundance rare species all can increase reproducibility.« less

  9. Evaluation of the reproducibility of amplicon sequencing with Illumina MiSeq platform.

    PubMed

    Wen, Chongqing; Wu, Liyou; Qin, Yujia; Van Nostrand, Joy D; Ning, Daliang; Sun, Bo; Xue, Kai; Liu, Feifei; Deng, Ye; Liang, Yuting; Zhou, Jizhong

    2017-01-01

    Illumina's MiSeq has become the dominant platform for gene amplicon sequencing in microbial ecology studies; however, various technical concerns, such as reproducibility, still exist. To assess reproducibility, 16S rRNA gene amplicons from 18 soil samples of a reciprocal transplantation experiment were sequenced on an Illumina MiSeq. The V4 region of 16S rRNA gene from each sample was sequenced in triplicate with each replicate having a unique barcode. The average OTU overlap, without considering sequence abundance, at a rarefaction level of 10,323 sequences was 33.4±2.1% and 20.2±1.7% between two and among three technical replicates, respectively. When OTU sequence abundance was considered, the average sequence abundance weighted OTU overlap was 85.6±1.6% and 81.2±2.1% for two and three replicates, respectively. Removing singletons significantly increased the overlap for both (~1-3%, p<0.001). Increasing the sequencing depth to 160,000 reads by deep sequencing increased OTU overlap both when sequence abundance was considered (95%) and when not (44%). However, if singletons were not removed the overlap between two technical replicates (not considering sequence abundance) plateaus at 39% with 30,000 sequences. Diversity measures were not affected by the low overlap as α-diversities were similar among technical replicates while β-diversities (Bray-Curtis) were much smaller among technical replicates than among treatment replicates (e.g., 0.269 vs. 0.374). Higher diversity coverage, but lower OTU overlap, was observed when replicates were sequenced in separate runs. Detrended correspondence analysis indicated that while there was considerable variation among technical replicates, the reproducibility was sufficient for detecting treatment effects for the samples examined. These results suggest that although there is variation among technical replicates, amplicon sequencing on MiSeq is useful for analyzing microbial community structure if used appropriately and with caution. For example, including technical replicates, removing spurious sequences and unrepresentative OTUs, using a clustering method with a high stringency for OTU generation, estimating treatment effects at higher taxonomic levels, and adapting the unique molecular identifier (UMI) and other newly developed methods to lower PCR and sequencing error and to identify true low abundance rare species all can increase reproducibility.

  10. Variation: Use It or Misuse It--Replication and Its Variants

    ERIC Educational Resources Information Center

    Drummond, Gordon B.; Vowler, Sarah L.

    2012-01-01

    In this article, the authors talk about variation and how variation between measurements may be reduced if sampling is not random. They also talk about replication and its variants. A replicate is a repeated measurement from the same experimental unit. An experimental unit is the smallest part of an experiment or a study that can be subject to a…

  11. Intervention for First Graders with Limited Number Knowledge: Large-Scale Replication of a Randomized Controlled Trial

    ERIC Educational Resources Information Center

    Gersten, Russell; Rolfhus, Eric; Clarke, Ben; Decker, Lauren E.; Wilkins, Chuck; Dimino, Joseph

    2015-01-01

    Replication studies are extremely rare in education. This randomized controlled trial (RCT) is a scale-up replication of Fuchs et al., which in a sample of 139 found a statistically significant positive impact for Number Rockets, a small-group intervention for at-risk first graders that focused on building understanding of number operations. The…

  12. Rainfall, discharge, and water-quality data during stormwater monitoring, H-1 storm drain, Oahu, Hawaii, July 1, 2009, to June 30, 2010

    USGS Publications Warehouse

    Presley, Todd K.; Jamison, Marcael T.J.

    2010-01-01

    Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. The program is designed to assess the effects of highway runoff and urban runoff collected by the H-1 storm drain on the Manoa-Palolo Drainage Canal. This report summarizes rainfall, discharge, and water-quality data collected between July 1, 2009, and June 30, 2010. As part of this program, rainfall and continuous discharge data were collected at the H-1 storm drain. During the year, sampling strategy and sample processing methods were modified to improve the characterization of the effects of discharge from the storm drain on the Manoa-Palolo Drainage Canal. During July 1, 2009, to February 1, 2010, samples were collected from only the H-1 storm drain. Beginning February 2, 2010, samples were collected simultaneously from the H-1 storm drain and the Manoa-Palolo Drainage Canal at a location about 50 feet upstream of the discharge point of the H-1 storm drain. Three storms were sampled during July 1, 2009, to June 30, 2010. All samples were collected using automatic samplers. For the storm of August 12, 2009, grab samples (for oil and grease, and total petroleum hydrocarbons) and a composite sample were collected. The composite sample was analyzed for total suspended solids, nutrients, and selected dissolved and total (filtered and unfiltered) trace metals (cadmium, chromium, nickel, copper, lead, and zinc). Two storms were sampled in March 2010 at the H-1 storm drain and from the Manoa-Palolo Drainage Canal. Two samples were collected during the storm of March 4, 2010, and six samples were collected during the storm of March 8, 2010. These two storms were sampled using the modified strategy, in which discrete samples from the automatic sampler were processed and analyzed individually, rather than as a composite sample, using the simultaneously collected samples from the H-1 storm drain and from the Manoa-Palolo Drainage Canal. The discrete samples were analyzed for some or all of the following constituents: total suspended solids, nutrients, oil and grease, and selected dissolved (filtered) trace metals (cadmium, chromium, nickel, copper, lead, and zinc). Five quality-assurance/quality-control samples were analyzed during the year. These samples included one laboratory-duplicate, one field-duplicate, and one matrix-spike sample prepared and analyzed with the storm samples. In addition, two inorganic blank-water samples, one sample at the H-1 storm drain and one sample at the Manoa-Palolo Drainage Canal, were collected by running the blank water (water purified of all inorganic constituents) through the sampling and processing systems after cleaning automatic sampler lines to verify that the sampling lines were not contaminated.

  13. Aqueous geochemical data from the analysis of stream-water samples collected in June and August 2008—Taylor Mountains 1:250,000- and Dillingham D-4 1:63,360-scale quadrangles, Alaska

    USGS Publications Warehouse

    Wang, Bronwen; Owens, Victoria; Bailey, Elizabeth; Lee, Greg

    2011-01-01

    We report on the chemical analysis of water samples collected from the Taylor Mountains 1:250,000- and Dillingham D-4 1:63,360-scale quadrangles, Alaska. Reported parameters include pH, conductivity, water temperature, major cation and anion concentrations, and trace-element concentrations. We collected the samples as part of a multiyear U.S. Geological Survey project entitled "Geologic and Mineral Deposit Data for Alaskan Economic Development." Data presented here are from samples collected in June and August 2008. Minimal interpretation accompanies this data release. This is the fourth release of aqueous geochemical data from this project; data from samples collected in 2004, 2005, and 2006 were published previously. The data in this report augment but do not duplicate or supersede the previous data releases. Site selection was based on a regional sampling strategy that focused on first- and second-order drainages. Water sample sites were selected on the basis of landscape parameters that included physiography, wetland extent, lithological changes, and a cursory field review of mineralogy from pan concentrates. Stream water in the study area is dominated by bicarbonate (HCO3-), although in a few samples more than 50 percent of the anionic charge can be attributed to sulfate (SO42-). The major-cation chemistry of these samples ranges from Ca2+-Mg2+ dominated to a mix of Ca2+-Mg2+-Na++K2+. In most cases, analysis of duplicate samples showed good agreement for the major cation and major anions with the exception of the duplicate samples at site 08TA565. At site 08TA565, Ca, Mg, Cl, and CaCO3 exceeded 25 percent and the concentrations of trace elements As, Fe and Mn also exceeded 25 percent in this duplicate pair. Chloride concentration varied by more than 25 percent in 5 of the 11 duplicated samples. Trace-element concentrations in these samples generally were at or near the detection limit for the method used and, except for Co at site 08TA565, generally good agreement was determined between duplicate samples for elements with detectable concentrations. Major-ion concentrations were below detection limits in all field blanks, and the trace-element concentrations also were generally below detection limits; however, Co, Mn, Na, Zn, Cl, and Hg were detected in one or more field blank samples.

  14. Groundwater-quality data in the Santa Barbara study unit, 2011: results from the California GAMA Program

    USGS Publications Warehouse

    Davis, Tracy A.; Kulongoski, Justin T.; Belitz, Kenneth

    2013-01-01

    Groundwater quality in the 48-square-mile Santa Barbara study unit was investigated by the U.S. Geological Survey (USGS) from January to February 2011, as part of the California State Water Resources Control Board (SWRCB) Groundwater Ambient Monitoring and Assessment (GAMA) Program’s Priority Basin Project (PBP). The GAMA-PBP was developed in response to the California Groundwater Quality Monitoring Act of 2001 and is being conducted in collaboration with the SWRCB and Lawrence Livermore National Laboratory (LLNL). The Santa Barbara study unit was the thirty-fourth study unit to be sampled as part of the GAMA-PBP. The GAMA Santa Barbara study was designed to provide a spatially unbiased assessment of untreated-groundwater quality in the primary aquifer system, and to facilitate statistically consistent comparisons of untreated-groundwater quality throughout California. The primary aquifer system is defined as those parts of the aquifers corresponding to the perforation intervals of wells listed in the California Department of Public Health (CDPH) database for the Santa Barbara study unit. Groundwater quality in the primary aquifer system may differ from the quality in the shallower or deeper water-bearing zones; shallow groundwater may be more vulnerable to surficial contamination. In the Santa Barbara study unit located in Santa Barbara and Ventura Counties, groundwater samples were collected from 24 wells. Eighteen of the wells were selected by using a spatially distributed, randomized grid-based method to provide statistical representation of the study unit (grid wells), and six wells were selected to aid in evaluation of water-quality issues (understanding wells). The groundwater samples were analyzed for organic constituents (volatile organic compounds [VOCs], pesticides and pesticide degradates, and pharmaceutical compounds); constituents of special interest (perchlorate and N-nitrosodimethylamine [NDMA]); naturally occurring inorganic constituents (trace elements, nutrients, major and minor ions, silica, total dissolved solids [TDS], alkalinity, and arsenic, chromium, and iron species); and radioactive constituents (radon-222 and gross alpha and gross beta radioactivity). Naturally occurring isotopes (stable isotopes of hydrogen and oxygen in water, stables isotopes of inorganic carbon and boron dissolved in water, isotope ratios of dissolved strontium, tritium activities, and carbon-14 abundances) and dissolved noble gases also were measured to help identify the sources and ages of the sampled groundwater. In total, 281 constituents and water-quality indicators were measured. Three types of quality-control samples (blanks, replicates, and matrix spikes) were collected at up to 12 percent of the wells in the Santa Barbara study unit, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. Blanks rarely contained detectable concentrations of any constituent, suggesting that contamination from sample collection procedures was not a significant source of bias in the data for the groundwater samples. Replicate samples generally were within the limits of acceptable analytical reproducibility. Matrix-spike recoveries were within the acceptable range (70 to 130 percent) for approximately 82 percent of the compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, untreated groundwater typically is treated, disinfected, and (or) blended with other waters to maintain water quality. Regulatory benchmarks apply to water that is served to the consumer, not to untreated groundwater. However, to provide some context for the results, concentrations of constituents measured in the untreated groundwater were compared with regulatory and non-regulatory health-based benchmarks established by the U.S. Environmental Protection Agency (USEPA) and CDPH and to non-regulatory benchmarks established for aesthetic concerns by CDPH. Comparisons between data collected for this study and benchmarks for drinking water are for illustrative purposes only and are not indicative of compliance or non-compliance with those benchmarks. All organic constituents and most inorganic constituents that were detected in groundwater samples from the 18 grid wells in the Santa Barbara study unit were detected at concentrations less than drinking-water benchmarks. Of the 220 organic and special-interest constituents sampled for at the 18 grid wells, 13 were detected in groundwater samples; concentrations of all detected constituents were less than regulatory and non-regulatory health-based benchmarks. In total, VOCs were detected in 61 percent of the 18 grid wells sampled, pesticides and pesticide degradates were detected in 11 percent, and perchlorate was detected in 67 percent. Polar pesticides and their degradates, pharmaceutical compounds, and NDMA were not detected in any of the grid wells sampled in the Santa Barbara study unit. Eighteen grid wells were sampled for trace elements, major and minor ions, nutrients, and radioactive constituents; most detected concentrations were less than health-based benchmarks. Exceptions are one detection of boron greater than the CDPH notification level (NL-CA) of 1,000 micrograms per liter (μg/L) and one detection of fluoride greater than the CDPH maximum contaminant level (MCL-CA) of 2 milligrams per liter (mg/L). Results for constituents with non-regulatory benchmarks set for aesthetic concerns from the grid wells showed that iron concentrations greater than the CDPH secondary maximum contaminant level (SMCL-CA) of 300 μg/L were detected in three grid wells. Manganese concentrations greater than the SMCL-CA of 50 μg/L were detected in seven grid wells. Chloride was detected at a concentration greater than the SMCL-CA recommended benchmark of 250 mg/L in four grid wells. Sulfate concentrations greater than the SMCL-CA recommended benchmark of 250 mg/L were measured in eight grid wells, and the concentration in one of these wells was also greater than the SMCL-CA upper benchmark of 500 mg/L. TDS concentrations greater than the SMCL-CA recommended benchmark of 500 mg/L were measured in 17 grid wells, and concentrations in six of these wells were also greater than the SMCL-CA upper benchmark of 1,000 mg/L.

  15. Time-resolved cathodoluminescence microscopy with sub-nanosecond beam blanking for direct evaluation of the local density of states.

    PubMed

    Moerland, Robert J; Weppelman, I Gerward C; Garming, Mathijs W H; Kruit, Pieter; Hoogenboom, Jacob P

    2016-10-17

    We show cathodoluminescence-based time-resolved electron beam spectroscopy in order to directly probe the spontaneous emission decay rate that is modified by the local density of states in a nanoscale environment. In contrast to dedicated laser-triggered electron-microscopy setups, we use commercial hardware in a standard SEM, which allows us to easily switch from pulsed to continuous operation of the SEM. Electron pulses of 80-90 ps duration are generated by conjugate blanking of a high-brightness electron beam, which allows probing emitters within a large range of decay rates. Moreover, we simultaneously attain a resolution better than λ/10, which ensures details at deep-subwavelength scales can be retrieved. As a proof-of-principle, we employ the pulsed electron beam to spatially measure excited-state lifetime modifications in a phosphor material across the edge of an aluminum half-plane, coated on top of the phosphor. The measured emission dynamics can be directly related to the structure of the sample by recording photon arrival histograms together with the secondary-electron signal. Our results show that time-resolved electron cathodoluminescence spectroscopy is a powerful tool of choice for nanophotonics, within reach of a large audience.

  16. Microstructural analysis of hot press formed 22MnB5 steel

    NASA Astrophysics Data System (ADS)

    Aziz, Nuraini; Aqida, Syarifah Nur; Ismail, Izwan

    2017-10-01

    This paper presents a microstructural study on hot press formed 22MnB5 steel for enhanced mechanical properties. Hot press forming process consists of simultaneous forming and quenching of heated blank. The 22MnB5 steel was processed at three different parameter settings: quenching time, water temperature and water flow rate. 22MnB5 was processed using 33 full factorial design of experiment (DOE). The full factorial DOE was designed using three factors of quenching time, water temperature and water flow rate at three levels. The factors level were quenching time range of 5 - 11 s, water temperature; 5 - 27°C and water flow rate; 20 - 40 L/min. The as-received and hot press forming processed steel was characterised for metallographic study and martensitic structure area percentage using JEOL Field Emission Scanning Electron Microscopic (FESEM). From the experimental finding, the hot press formed 22MnB5 steel consisted of 50 to 84% martensitic structure area. The minimum quenching time of 8 seconds was required to obtain formed sample with high percentage of martensite. These findings contribute to initial design of processing parameters in hot press forming of 22MnB5 steel blanks for automotive component.

  17. Two months of disdrometer data in the Paris area

    NASA Astrophysics Data System (ADS)

    Gires, Auguste; Tchiguirinskaia, Ioulia; Schertzer, Daniel

    2018-05-01

    The Hydrology, Meteorology, and Complexity laboratory of École des Ponts ParisTech (hmco.enpc.fr) has made a data set of optical disdrometer measurements available that come from a campaign involving three collocated devices from two different manufacturers, relying on different underlying technologies (one Campbell Scientific PWS100 and two OTT Parsivel2 instruments). The campaign took place in January-February 2016 in the Paris area (France). Disdrometers provide access to information on the size and velocity of drops falling through the sampling area of the devices of roughly a few tens of cm2. It enables the drop size distribution to be estimated and rainfall microphysics, kinetic energy, or radar quantities, for example, to be studied further. Raw data, i.e. basically a matrix containing a number of drops according to classes of size and velocity, along with more aggregated ones, such as the rain rate or drop size distribution with filtering, are available. Link to the data set: https://zenodo.org/record/1240168 (DOI: https://doi.org/10.5281/zenodo.1240168).

  18. 47 CFR 73.646 - Telecommunications Service on the Vertical Blanking Interval and in the Visual Signal.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Blanking Interval and in the Visual Signal. 73.646 Section 73.646 Telecommunication FEDERAL COMMUNICATIONS... transmission of data, processed information, or any other communication in either a digital or analog mode. (b... kinds of service that may be provided include, but are not limited to, teletext, paging, computer...

  19. 47 CFR 73.646 - Telecommunications Service on the Vertical Blanking Interval and in the Visual Signal.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Blanking Interval and in the Visual Signal. 73.646 Section 73.646 Telecommunication FEDERAL COMMUNICATIONS... transmission of data, processed information, or any other communication in either a digital or analog mode. (b... kinds of service that may be provided include, but are not limited to, teletext, paging, computer...

  20. 47 CFR 73.646 - Telecommunications Service on the Vertical Blanking Interval and in the Visual Signal.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Blanking Interval and in the Visual Signal. 73.646 Section 73.646 Telecommunication FEDERAL COMMUNICATIONS... transmission of data, processed information, or any other communication in either a digital or analog mode. (b... kinds of service that may be provided include, but are not limited to, teletext, paging, computer...

  1. 47 CFR 73.646 - Telecommunications Service on the Vertical Blanking Interval and in the Visual Signal.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Blanking Interval and in the Visual Signal. 73.646 Section 73.646 Telecommunication FEDERAL COMMUNICATIONS... transmission of data, processed information, or any other communication in either a digital or analog mode. (b... kinds of service that may be provided include, but are not limited to, teletext, paging, computer...

  2. U.S. Foreign Policy’s Role in Homeland Security: The Egyptian Case

    DTIC Science & Technology

    2011-12-01

    Robert E. Looney THIS PAGE INTENTIONALLY LEFT BLANK i REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 Public reporting burden for this...CONTENTS I . INTRODUCTION........................................................................................................1 A. MAJOR RESEARCH...PAGE INTENTIONALLY LEFT BLANK xi ACKNOWLEDGMENTS I would like to thank Dr. Abbas Kadhim and Dr. Robert Looney for their support, expertise, and

  3. A big blank white canvas? Mapping and modeling human impact in Antarctica

    Treesearch

    Steve Carver; Tina Tin

    2015-01-01

    Antarctica is certainly what most people would consider being the world's last great wilderness; largely untouched and undeveloped by humans. Yet it is not inviolate - there are scientific bases, tourist operations, expeditions, airstrips and even roads. Although these impacts are by and large limited in extent, their very presence in an otherwise "blank...

  4. The Disposition of Topically Applied Agents

    DTIC Science & Technology

    1981-09-24

    S . op . cit. 28. Scheuplein R.J., Blank I.H. op. cit. 29. Lorenzetti O.J. Cosmet. Toil. 93_:49-50, 1978. 30. Scheuplein R.J., Blank I.H. op. cit...Riegelman S . op . cit. 37. Wester R. , Noonan P J. invest. Derm. 72:92-94, 1978. 38. Mansel-Jones D., Taylor T., Doyle E., Chasseud L.F., Darraugh A

  5. Hardwood Blanks Expand Export Opportunities

    Treesearch

    Bruce G. Hansen; Philip A. Araman

    1985-01-01

    This article reviews the latest statistics pertaining to the export of hardwood lumber to the Pacific Rim; discusses possible reasons for the emergence and growth of this market; offers alternatives to rough hardwood lumber (two forms of value-added, hardwood blanks); and develops estimates of prices needed at the mill to earn a 30% return on investment from the...

  6. Optimal Number of Gaps in C-Test Passages

    ERIC Educational Resources Information Center

    Baghaei, Purya

    2011-01-01

    This study addresses the issue of the optimal number of gaps in C-Test passages. An English C-Test battery containing four passages each having 40 blanks was given to 104 undergraduate students of English. The data were entered into SPSS spreadsheet. Out of the complete data with 160 blanks seven additional datasets were constructed. In the first…

  7. The Use of Application Blanks as Pre-Screening Devices in Employee Selection: An Assessment of Practices in Public Schools.

    ERIC Educational Resources Information Center

    Bredeson, Paul V.

    1988-01-01

    Reports on a study of the use of employment application blanks as prescreening devices in public school employee selection. Findings suggest two major areas for further research. The first relates to legal compliance with Equal Opportunity Employment guidelines. The second concerns information relevancy to personnel selection. (JAM)

  8. Meeting the Solid Wood Needs of the Furniture and Cabinet Industries: Standard-Size Hardwood Blanks

    Treesearch

    Philip A. Araman; Charles J Gatchell; Hugh W. Reynolds

    1982-01-01

    Standard-size, kiln-dried hardwood blanks (panels) of specified lengths, widths, thicknesses, and qualities can be used instead of lumber to produce rough dimension furniture parts. Standard sizes were determined by analyzing thousands of part requirements from 20 furniture and 12 kitchen cabinet companies. The International Woodworking Machinery and Furniture Supply...

  9. System 6 alternatives: an economic analysis

    Treesearch

    Bruce G. Hansen; Hugh W. Reynolds; Hugh W. Reynolds

    1984-01-01

    Three System 6 mill-size alternatives were designed and evaluated to determine their overall economic potential for producing standard-size hardwood blanks. Internal rates of return ranged from about 15 to 35 percent after taxes. Cost per square foot of blanks ranged from about $0.88 to $1.19, depending on mill size and the amount of new investment required.

  10. Production of EUV mask blanks with low killer defects

    NASA Astrophysics Data System (ADS)

    Antohe, Alin O.; Kearney, Patrick; Godwin, Milton; He, Long; John Kadaksham, Arun; Goodwin, Frank; Weaver, Al; Hayes, Alan; Trigg, Steve

    2014-04-01

    For full commercialization, extreme ultraviolet lithography (EUVL) technology requires the availability of EUV mask blanks that are free of defects. This remains one of the main impediments to the implementation of EUV at the 22 nm node and beyond. Consensus is building that a few small defects can be mitigated during mask patterning, but defects over 100 nm (SiO2 equivalent) in size are considered potential "killer" defects or defects large enough that the mask blank would not be usable. The current defect performance of the ion beam sputter deposition (IBD) tool will be discussed and the progress achieved to date in the reduction of large size defects will be summarized, including a description of the main sources of defects and their composition.

  11. Actinic defect counting statistics over 1-cm2 area of EUVL mask blank

    NASA Astrophysics Data System (ADS)

    Jeong, Seongtae; Lai, Chih-wei; Rekawa, Senajith; Walton, Christopher C.; Bokor, Jeffrey

    2000-07-01

    As a continuation of comparison experiments between EUV inspection and visible inspection of defects on EUVL mask blanks, we report on the result of an experiment where the EUV defect inspection tool is used to perform at-wavelength defect counting over 1 cm2 of EUVL mask blank. Initial EUV inspection found five defects over the scanned area and the subsequent optical scattering inspection was able to detect all of the five defects. Therefore, if there are any defects that are only detectable by EUV inspection, the density is lower than the order of unity per cm2. An upgrade path to substantially increase the overall throughput of the EUV inspection system is also identified in the manuscript.

  12. Formability analysis of austenitic stainless steel-304 under warm conditions

    NASA Astrophysics Data System (ADS)

    Lade, Jayahari; Singh, Swadesh Kumar; Banoth, Balu Naik; Gupta, Amit Kumar

    2013-12-01

    A warm deep drawing process of austenitic stainless steel-304 (ASS-304) of circular blanks with coupled ther mal analysis is studied in this article. 65 mm blanks were deep drawn at different temperatures and thickness distribution is experimentally measured after cutting the drawn component into two halves. The process is simulated using explicit fin ite element code LS-DYNA. A Barlat 3 parameter model is used in the simulation, as the material is anisotropic up to 30 0°C. Material properties for the simulation are determined at different temperatures using a 5 T UTM coupled with a furn ace. In this analysis constant punch speed and variable blank holder force (BHF) is applied to draw cups without wrinkle.

  13. Fill in the blank: culture jamming and the advertising of agency.

    PubMed

    Lambert-Beatty, Carrie

    2010-01-01

    This article is a review on billboard liberation and some other proj-ects that develop the idea of talking back or over advertising in a playful and youthful way. In one of them, Ji Lee's Bubble Project, an artist places blank thought-bubble stickers on street advertisements and waits to see what people write on them, completing the work of art and transgression. In other initiative, blank pages with the word God were placed around the city in place of advertising, inviting people to complete the prayer/complaint and to participate in a Suggestion Box, a project that collected "suggestions" from people out in the street. A review of playful and youthful ways to "rebel" against the impositions of powers like media and advertising.

  14. A Comparison Study of Sampling and Analyzing Volatile Organic Compounds in Air in Kuwait by Using Tedlar Bags/Canisters and GC-MS with a Cryogenic Trap

    PubMed Central

    Tang, Hongmao; Beg, Khaliq R.; Al-Otaiba, Yousef

    2006-01-01

    Kuwait experiences desert climatic weather. Due to the extreme hot and dry conditions in this country, some analytical phenomena have been discovered. Therefore, a systematic study of sampling and analyzing volatile organic compounds in air by using GC-MS with a cryogenic trap is reported in this paper. This study included comparisons of using different sample containers such as Tedlar bags and SUMMA canisters, and different cryogenic freezing-out air volumes in the trap. Calibration curves for different compounds and improvement of replicated analysis results were also reported here. The study found that using different sample containers produced different results. Analysis of ambient air samples collected in Tedlar bags obtained several volatile organic compounds with large concentrations compared to using SUMMA canisters. Therefore, to choose a sample container properly is a key element for successfully completing a project. Because GC-MS with a cryogenic trap often generates replicated results with poor agreement, an internal standard added to gas standards and air samples by using a gas syringe was tested. The study results proved that it helped to improve the replicated results. PMID:16699723

  15. A comparison study of sampling and analyzing volatile organic compounds in air in Kuwait by using Tedlar bags/canisters and GC-MS with a cryogenic trap.

    PubMed

    Tang, Hongmao; Beg, Khaliq R; Al-Otaiba, Yousef

    2006-05-12

    Kuwait experiences desert climatic weather. Due to the extreme hot and dry conditions in this country, some analytical phenomena have been discovered. Therefore, a systematic study of sampling and analyzing volatile organic compounds in air by using GC-MS with a cryogenic trap is reported in this paper. This study included comparisons of using different sample containers such as Tedlar bags and SUMMA canisters, and different cryogenic freezing-out air volumes in the trap. Calibration curves for different compounds and improvement of replicated analysis results were also reported here. The study found that using different sample containers produced different results. Analysis of ambient air samples collected in Tedlar bags obtained several volatile organic compounds with large concentrations compared to using SUMMA canisters. Therefore, to choose a sample container properly is a key element for successfully completing a project. Because GC-MS with a cryogenic trap often generates replicated results with poor agreement, an internal standard added to gas standards and air samples by using a gas syringe was tested. The study results proved that it helped to improve the replicated results.

  16. Moscow Test Well, INEL Oversight Program: Aqueous geochemistry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCurry, M.; Fromm, J.; Welhan, J.

    1992-09-29

    This report presents a summary and interpretation of data gathered during sampling of the Moscow Test Well at Moscow, Idaho during April and May of 1992. The principal objectives of this chemical survey were to validate sampling procedures with a new straddle packer sampling tool in a previously hydrologically well characterized and simple sampling environment, and to compare analytical results from two independent labs for reproducibility of analytical results. Analytes included a wide range of metals, anions, nutrients, BNA`s, and VOC`s. Secondary objectives included analyzing of waters from a large distilled water tank (utilized for all field laboratory purposes asmore » ``pure`` stock water), of water which passed through a steamer used to clean the packer, and of rinsates from the packer tool itself before it was lowered into the test well. Analyses were also obtained of blanks and spikes for data validation purposes.« less

  17. Investigation of Tank 241-AW-104 Composite Floating Layer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meznarich, H. K.; Bolling, S. D.; Lachut, J. S.

    Seven grab samples and one field blank were taken from Tank 241-AW-104 (AW-104) on June 2, 2017, and received at 222-S Laboratory on June 5, 2017. A visible layer with brown solids was observed floating on the top of two surface tank waste samples (4AW-17-02 and 4AW 17 02DUP). The floating layer from both samples was collected, composited, and submitted for chemical analyses and solid phase characterization in order to understand the composition of the floating layer. Tributyl phosphate and tridecane were higher in the floating layer than in the aqueous phase. Density in the floating layer was slightly lowermore » than the mean density of all grab samples. Sodium nitrate and sodium carbonate were major components with a trace of gibbsite and very small size agglomerates were present in the solids of the floating layer. The supernate consisted of organics, soluble salt, and particulates.« less

  18. Pressure-driven mesofluidic platform integrating automated on-chip renewable micro-solid-phase extraction for ultrasensitive determination of waterborne inorganic mercury.

    PubMed

    Portugal, Lindomar A; Laglera, Luis M; Anthemidis, Aristidis N; Ferreira, Sérgio L C; Miró, Manuel

    2013-06-15

    A dedicated pressure-driven mesofluidic platform incorporating on-chip sample clean-up and analyte preconcentration is herein reported for expedient determination of trace level concentrations of waterborne inorganic mercury. Capitalizing upon the Lab-on-a-Valve (LOV) concept, the mesofluidic device integrates on-chip micro-solid phase extraction (μSPE) in automatic disposable mode followed by chemical vapor generation and gas-liquid separation prior to in-line atomic fluorescence spectrometric detection. In contrast to prevailing chelating sorbents for Hg(II), bare poly(divinylbenzene-N-vinylpyrrolidone) copolymer sorptive beads were resorted to efficient uptake of Hg(II) in hydrochloric acid milieu (pH=2.3) without the need for metal derivatization nor pH adjustment of prior acidified water samples for preservation to near-neutral conditions. Experimental variables influencing the sorptive uptake and retrieval of target species and the evolvement of elemental mercury within the miniaturized integrated reaction chamber/gas-liquid separator were investigated in detail. Using merely <10 mg of sorbent, the limits of detection and quantification at the 3s(blank) and 10s(blank) levels, respectively, for a sample volume of 3 mL were 12 and 42 ng L(-1) Hg(II) with a dynamic range extending up to 5.0 μg L(-1). The proposed mesofluidic platform copes with the requirements of regulatory bodies (US-EPA, WHO, EU-Commission) for drinking water quality and surface waters that endorse maximum allowed concentrations of mercury spanning from 0.07 to 6.0 μg L(-1). Demonstrated with the analysis of aqueous samples of varying matrix complexity, the LOV approach afforded reliable results with relative recoveries of 86-107% and intermediate precision down to 9% in the renewable μSPE format. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Slurry micro-sampling technique for use in argon-helium microwave induced plasma optical emission spectrometry.

    PubMed

    Ślachciński, Mariusz

    2016-12-01

    The Flow Focusing Pneumatic Nebulizer (FFPN) working at low liquid flow rates was evaluated for the elemental analysis in slurried samples by argon-helium microwave induced plasma optical emission spectrometry (MIP-OES). The obtained results achieved were compared with commercially available V-groove Babington type nebulizer (VBPN). A univariate approach and the simplex optimization procedure were used to achieve optimized conditions and derive analytical figures of merit. Analytical performance of the micro nebulization system was characterized by a determination of the limits of detection (LODs), the precision (RSDs) and the wash-out times for Ba, Ca, Cd, Cu, Fe, Mg, Mn, Pb and Sr. The experimental concentration detection limits for simultaneous determination, calculated as the concentration giving a signal equal to three times of the standard deviation of the blank (LOD, 3σ blank criterion, peak height) were 0.9, 0.2, 0.3, 0.2, 0.3, 0.1, 0.2, 0.4, 0.4 and 0.3ngmL -1 for Ba, Ca, Cd, Cu, Fe, Mg, Mn, Pb and Sr, respectively. The method offers relatively good precision (RSD ranged from 5% to 8%) for micro-slurry sampling analysis. Analyses of the certified reference materials (NRCC DOLT-2, GBW 07302 and SRM 2710) were performed in order to determine the accuracy available with the presented nebulization systems. The measured contents of elements in the reference materials were in satisfactory agreement with the certified values. In addition, these elements were determined in two real samples. Slurry concentration up to 3% m/v (particles <20μm), prepared in 10% m/v HCl through the application of ultrasonic agitation, was used with calibration by the standard addition technique. An ultrasonic probe was used to homogenize the slurry in the polypropylene bottle just before its introduction into the nebulizer. The nebulizers exhibited no clogging problems. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Fluid sampling apparatus and method

    DOEpatents

    Yeamans, David R.

    1998-01-01

    Incorporation of a bellows in a sampling syringe eliminates ingress of contaminants, permits replication of amounts and compression of multiple sample injections, and enables remote sampling for off-site analysis.

  1. Evaluation of a Fluidized-Bed Paint Stripper at Red River Army Depot

    DTIC Science & Technology

    1992-04-15

    are summarized in Table 3-1. Calibra- tion guidelines are described in more detail in Appendix E. 0 Onsite audits of dry gas meters, thermocouples...experienced laboratory per- sonnel. o Internal and external audits to ensure accuracy in sampling and analysis. o Reagent, filter, and field blanks to...0.0 0.0 If below detection limits, replace 0 with 1. 0 0 0 ?Mn < polutant > mam mg 0.0 0.0 0.0 Co cpoliuLant> concentration gr/dscf 0.000E*00 0.000E.00

  2. Cultural Resources Sample Survey of the Bayou Cocodrie and Tributaries Project, St. Landry, Evangeline and Avoyelles Parishes, Louisiana.

    DTIC Science & Technology

    1987-02-06

    noweinv m idensitir 6F block ntiAbe) - This report presents the results of a probabilistic survey T of five per cent f -the wooded areas within the...bottle necks, and one piece of slag . The lack of structural remains, such as bricks or nails, 105 THIS PAGE BLANK 106 0 loom IWO I > - MIRE SITE .q...melted 1 Slag 1 Total 26 146 CHAPTER VII A COMPARISON OF SITE DISTRIBUTIONS IN THE PROJECT AREA Using the data gathered during this survey, comparisons

  3. Linking Sister Chromatid Cohesion to Apoptosis and Aneuploidy in the Development of Breast Cancer

    DTIC Science & Technology

    2005-07-01

    antibody. Jurkat cells were ZE in wheat germ extract was .4 Claved fd21 transfected with blank vectors (B), treated with • • incubated in the presence...nonisotopic) hRad21 in wheat germ extracts by FPLC fractions 13-20. Samples were analyzed on an SDS-6% PAGE gel followed by Western bloting with hRda2l C...in vitro translated unlabelled hRad21 in wheat germ extracts and assaying the cleavage in Rad21 immunoblots (Fig. 5C). The broad-spectrum caspase

  4. Data for a regional approach to the development of an effects-based nutrient criterion for wadable streams

    USGS Publications Warehouse

    Crawford, J. Kent; Loper, Connie A.; Beaman, Joseph R.; Soehl, Anna G.; Brown, Will S.

    2007-01-01

    States are required by the U.S. Environmental Protection Agency to establish nutrient criteria (concentrations of nutrients above which water quality is deteriorated) as part of their water-quality regulations. A study of wadable streams in the Mid-Atlantic Region was undertaken by the U.S. Geological Survey, the U.S. Environmental Protection Agency, and the Maryland Department of the Environment, with assistance from the Pennsylvania Department of Environmental Protection, to help define current concentrations of nutrients in streams with the goal of associating different nutrient-concentration levels with their effects on water quality. During the summers of 2004 and 2005, diel concentrations of dissolved oxygen, nutrient concentrations, concentrations of chlorophyll a in attached algae, and algal-community structure were measured at 46 stream sites in Maryland, Pennsylvania, Virginia, and West Virginia. Data from this work can be used by individual state agencies to define nutrient criteria. Quality-control measures for the study included submitting blank samples, duplicate samples, and reference samples for analysis of nutrients, total organic carbon, chlorophyll a, and algal biomass. Duplicate and split samples were submitted for periphyton identifications. Three periphyton split samples were sent to an independent lab for a check on periphyton identifications. Neither total organic carbon nor nutrients were detected in blank samples. Concentrations of nutrients and total organic carbon were similar for most duplicate sample pairs, with the exception of a duplicate pair from Western Run. Concentrations of ammonia plus organic nitrogen for this duplicate pair differed by as much as 34 percent. Total organic carbon for the duplicate pair from Western Run differed by 102 percent. The U.S. Geological Survey National Water Quality Laboratory performance on the only valid reference sample submitted was excellent; the relative percent difference values were no larger than 5 percent for any constituent analyzed. For periphyton identifications, duplicate samples had Jaccard Coefficient of Community values slightly greater than 0.5. This indicates the periphyton sampling protocol used provided a sample that was only moderately reproducible. Jaccard Coefficients for three periphyton samples split between two independent labs were 0.2, 0.11, and 0.08. These very low values suggest a poor concurrence on species identifications performed by the two labs. As a result of these quality-control samples, the slides prepared for diatom identifications were sent to the Academy of Natural Sciences for re-identification. Caution is urged when interpreting periphyton-community information from this study. This report and the raw data from the study are available online at http://pubs.usgs.gov/ds257

  5. Efficient simulation of press hardening process through integrated structural and CFD analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palaniswamy, Hariharasudhan; Mondalek, Pamela; Wronski, Maciek

    Press hardened steel parts are being increasingly used in automotive structures for their higher strength to meet safety standards while reducing vehicle weight to improve fuel consumption. However, manufacturing of sheet metal parts by press hardening process to achieve desired properties is extremely challenging as it involves complex interaction of plastic deformation, metallurgical change, thermal distribution, and fluid flow. Numerical simulation is critical for successful design of the process and to understand the interaction among the numerous process parameters to control the press hardening process in order to consistently achieve desired part properties. Until now there has been no integratedmore » commercial software solution that can efficiently model the complete process from forming of the blank, heat transfer between the blank and tool, microstructure evolution in the blank, heat loss from tool to the fluid that flows through water channels in the tools. In this study, a numerical solution based on Altair HyperWorks® product suite involving RADIOSS®, a non-linear finite element based structural analysis solver and AcuSolve®, an incompressible fluid flow solver based on Galerkin Least Square Finite Element Method have been utilized to develop an efficient solution for complete press hardening process design and analysis. RADIOSS is used to handle the plastic deformation, heat transfer between the blank and tool, and microstructure evolution in the blank during cooling. While AcuSolve is used to efficiently model heat loss from tool to the fluid that flows through water channels in the tools. The approach is demonstrated through some case studies.« less

  6. Influence of asymmetrical drawing radius deviation in micro deep drawing

    NASA Astrophysics Data System (ADS)

    Heinrich, L.; Kobayashi, H.; Shimizu, T.; Yang, M.; Vollertsen, F.

    2017-09-01

    Nowadays, an increasing demand for small metal parts in electronic and automotive industries can be observed. Deep drawing is a well-suited technology for the production of such parts due to its excellent qualities for mass production. However, the downscaling of the forming process leads to new challenges in tooling and process design, such as high relative deviation of tool geometry or blank displacement compared to the macro scale. FEM simulation has been a widely-used tool to investigate the influence of symmetrical process deviations as for instance a global variance of the drawing radius. This study shows a different approach that allows to determine the impact of asymmetrical process deviations on micro deep drawing. In this particular case the impact of an asymmetrical drawing radius deviation and blank displacement on cup geometry deviation was investigated for different drawing ratios by experiments and FEM simulation. It was found that both variations result in an increasing cup height deviation. Nevertheless, with increasing drawing ratio a constant drawing radius deviation has an increasing impact, while blank displacement results in a decreasing offset of the cups geometry. This is explained by different mechanisms that result in an uneven cup geometry. While blank displacement leads to material surplus on one side of the cup, an unsymmetrical radius deviation on the other hand generates uneven stretching of the cups wall. This is intensified for higher drawing ratios. It can be concluded that the effect of uneven radius geometry proves to be of major importance for the production of accurately shaped micro cups and cannot be compensated by intentional blank displacement.

  7. Numerical simulation of X90 UOE pipe forming process

    NASA Astrophysics Data System (ADS)

    Zou, Tianxia; Ren, Qiang; Peng, Yinghong; Li, Dayong; Tang, Ding; Han, Jianzeng; Li, Xinwen; Wang, Xiaoxiu

    2013-12-01

    The UOE process is an important technique to manufacture large-diameter welding pipes which are increasingly applied in oil pipelines and offshore platforms. The forming process of UOE mainly consists of five successive operations: crimping, U-forming, O-forming, welding and mechanical expansion, through which a blank is formed into a pipe in a UOE pipe mill. The blank with an appropriate edge bevel is bent into a cylindrical shape by crimping (C-forming), U-forming and O-forming successively. After the O-forming, there is an open-seam between two ends of the plate. Then, the blank is welded by automatic four-electrode submerged arc welding technique. Subsequently, the welded pipe is expanded with a mechanical expander to get a high precision circular shape. The multiple operations in the UOE mill make it difficult to control the quality of the formed pipe. Therefore, process design mainly relies on experience in practical production. In this study, the UOE forming of an API X90 pipe is studied by using finite element simulation. The mechanical properties tests are performed on the API X90 pipeline steel blank. A two-dimensional finite element model under the hypothesis of plane strain condition is developed to simulate the UOE process according to data coming from the workshop. A kinematic hardening model is used in the simulation to take the Bauschinger effect into account. The deformation characteristics of the blank during the forming processes are analyzed. The simulation results show a significant coherence in the geometric configurations comparing with the practical manufacturing.

  8. Experimental and Numerical Investigations of Constraint Effect on Deformation Behavior of Tailor-Welded Blanks

    NASA Astrophysics Data System (ADS)

    Li, Yanhua; Lin, Jianping

    2015-08-01

    Tailor-welded blanks (TWBs) have been considered as a productive sheet forming method in automotive industries. However, formability of TWBs is reduced due to different properties or thicknesses of the blanks and is a challenge for manufacturing designers. The plastic capacity of TWBs is decreased even when the material and thickness are the same. The constraint effect of the laser weld (including weld and heat-affected zone) material in the forming process of similar TWBs is a key problem to be solved in the research, development and application of thin-sheet TWBs. In this paper, uniaxial tensile tests with full-field strain measurement by digital image correlation and Erichsen tests are performed to investigate the constraint effect on deformation behavior and explore the mechanism of decreasing formability of similar TWBs. In addition, finite element models are conducted under ABAQUS code to further reveal the phenomenal behavior of the constraint effect. The results of the base material and welded blanks are compared for characterizing the differences. Furthermore, in order to better understand this mechanism, theoretical and numerical investigations are employed and compared to interpret the constraint effect of laser weld on the deformation behavior of TWBs. An index is proposed to quantify the constraint effect. Results show that the constraint effect of laser weld appears in both stretch forming and drawing of TWBs. Strain paths are approaching the plane strain condition as compared to the monolithic blank due to the constraint effect. Constraint effect is a major factor affecting the formability of TWBs when the failure occurs away from the weld seam.

  9. Design and Field Procedures in the US National Comorbidity Survey Replication Adolescent Supplement (NCS-A)

    PubMed Central

    Kessler, Ronald C.; Avenevoli, Shelli; Costello, E. Jane; Green, Jennifer Greif; Gruber, Michael J.; Heeringa, Steven; Merikangas, Kathleen R.; Pennell, Beth-Ellen; Sampson, Nancy A.; Zaslavsky, Alan M.

    2009-01-01

    An overview is presented of the design and field procedures of the US National Comorbidity Survey Replication Adolescent Supplement (NCS-A), a US face-to-face household survey of the prevalence and correlates of DSM-IV mental disorders. The survey was based on a dual-frame design that included 904 adolescent residents of the households that participated in the US National Comorbidity Survey Replication (85.9% response rate) and 9,244 adolescent students selected from a nationally representative sample of 320 schools (74.7% response rate). After expositing the logic of dual-frame designs, comparisons are presented of sample and population distributions on Census socio-demographic variables and, in the school sample, school characteristics. These document only minor differences between the samples and the population. The results of statistical analysis of the bias-efficiency trade-off in weight trimming are then presented. These show that modest trimming meaningfully reduces mean squared error. Analysis of comparative sample efficiency shows that the household sample is more efficient than the school sample, leading to the household sample getting a higher weight relative to its size in the consolidated sample relative to the school sample. Taken together, these results show that the NCS-A is an efficient sample of the target population with good representativeness on a range of socio-demographic and geographic variables. PMID:19507169

  10. A comparison of technical replicate (cuts) effect on lamb Warner-Bratzler shear force measurement precision.

    PubMed

    Holman, B W B; Alvarenga, T I R C; van de Ven, R J; Hopkins, D L

    2015-07-01

    The Warner-Bratzler shear force (WBSF) of 335 lamb m. longissimus lumborum (LL) caudal and cranial ends was measured to examine and simulate the effect of replicate number (r: 1-8) on the precision of mean WBSF estimates and to compare LL caudal and cranial end WBSF means. All LL were sourced from two experimental flocks as part of the Information Nucleus slaughter programme (CRC for Sheep Industry Innovation) and analysed using a Lloyd Texture analyser with a Warner-Bratzler blade attachment. WBSF data were natural logarithm (ln) transformed before statistical analysis. Mean ln(WBSF) precision improved as r increased; however the practical implications support an r equal to 6, as precision improves only marginally with additional replicates. Increasing LL sample replication results in better ln(WBSF) precision compared with increasing r, provided that sample replicates are removed from the same LL end. Cranial end mean WBSF was 11.2 ± 1.3% higher than the caudal end. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  11. Sampling design trade-offs in occupancy studies with imperfect detection: examples and software

    USGS Publications Warehouse

    Bailey, L.L.; Hines, J.E.; Nichols, J.D.

    2007-01-01

    Researchers have used occupancy, or probability of occupancy, as a response or state variable in a variety of studies (e.g., habitat modeling), and occupancy is increasingly favored by numerous state, federal, and international agencies engaged in monitoring programs. Recent advances in estimation methods have emphasized that reliable inferences can be made from these types of studies if detection and occupancy probabilities are simultaneously estimated. The need for temporal replication at sampled sites to estimate detection probability creates a trade-off between spatial replication (number of sample sites distributed within the area of interest/inference) and temporal replication (number of repeated surveys at each site). Here, we discuss a suite of questions commonly encountered during the design phase of occupancy studies, and we describe software (program GENPRES) developed to allow investigators to easily explore design trade-offs focused on particularities of their study system and sampling limitations. We illustrate the utility of program GENPRES using an amphibian example from Greater Yellowstone National Park, USA.

  12. Fighting Tomorrows Fire Today: Leveraging Intelligence for Scenario-Based Exercise Design

    DTIC Science & Technology

    2014-03-01

    Management and Budget, Paperwork Reduction Project (0704–0188) Washington, DC 20503. 1. AGENCY USE ONLY (Leave blank) 2. REPORT DATE March 2014 3...IPG Improvised Projected Grenade IT information technology LLIS Lessons Learned Information Sharing MEP Master Exercise Practitioner MOU...Disaster?” Natural Hazards 18, no. 1 (1998): 87–88. xvii THIS PAGE INTENTIONALLY LEFT BLANK xviii

  13. Field of Gifted Dreams: An Interview with Susan Assouline

    ERIC Educational Resources Information Center

    Henshon, Suzanna E.

    2016-01-01

    Susan G. Assouline is the director of the Belin-Blank Center, holds the Myron and Jacqueline N. Blank Endowed Chair in Gifted Education, and is a professor of school psychology. She received her BS in general science with a teaching endorsement, her EdS in school psychology, and her PhD in psychological and quantitative foundations, all from the…

  14. A Decision Support Personnel Monitoring Database System Prototype for the United States Marine Corps.

    DTIC Science & Technology

    1985-12-19

    Officer. The second space represents the current pay grade. The third space E indi- cates the officer has a least four years of enlisted active service...second space can only be 1-6. The third space can only be E or blank. Warrant Officers and PGRD 04 and above will have the third space blank even if

  15. Information Operations in Pursuit of Terrorists

    DTIC Science & Technology

    2007-09-01

    230 Blanking Out operations is a term used to somehow undertake partial and region-specific censorship ...4302, and to the Office of Management and Budget, Paperwork Reduction Project (0704-0188) Washington DC 20503. 1. AGENCY USE ONLY (Leave blank) 2...to highlight the use of information operations by terrorist organizations and in particular its use by Al Qaeda. In order to compare the complete

  16. Optimizing Marine Corps Personnel Assignments Using an Integer Programming Model

    DTIC Science & Technology

    2012-12-01

    Corps. vi THIS PAGE INTENTIONALLY LEFT BLANK vii TABLE OF CONTENTS I. INTRODUCTION ...throughout our careers. xvi THIS PAGE INTENTIONALLY LEFT BLANK 1 I. INTRODUCTION The Marine Corps Manpower and Reserve Affairs (M&RA) office has the...2012 BAH Rates-with Dependents. Defense Travel Mangement Office. (2011, December). 2012 BAH Rates-without Dependents. M ileage C ost 1 Per D iem

  17. 77 FR 27788 - Notice of Issuance of Final Determination Concerning Special Ops Flashlights and Sportsman...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-11

    ... create a slight V shape; inserting the PCB into the battery tube; inserting the 3 V Lithium battery into... items are attached together. The power source used for the LED blank assemblies is a 3 volt lithium battery which is imported separately and sourced from China. The battery is attached to the LED blank in...

  18. The MDT Innovation: Machine-Scoring of Fill-in-the-Blank Tests.

    ERIC Educational Resources Information Center

    Anderson, Paul S.

    The Multi-Digit Technologies (MDT) testing technique is discussed as the first major advance in computer assisted testing in several decades. The MDT testing method uses fill-in-the-blank or completion-type questions, with an alphabetized long list of possible responses. An MDT answer sheet is used to record the code number of the answer. For…

  19. New technology for low-grade hardwood utilization: System 6

    Treesearch

    Hugh W. Reynolds; Charles J. Gatchell

    1982-01-01

    System 6 is a technology for converting low-grade hardwood to high-valued end products such as furniture and kitchen cabinets. Among its concepts are: (1) a new, nonlumber product called standard-size blanks; (2) highly automated methods of converting the logs to blanks; (3) total processing of every board that contains a minimum-size cutting; and (4) minimized machine...

  20. On the modeling of separation foils in thermoforming simulations

    NASA Astrophysics Data System (ADS)

    Margossian, Alexane; Bel, Sylvain; Hinterhölzl, Roland

    2016-10-01

    Composite forming simulations consist in modelling the forming process of composite components to anticipate the occurrence of potential flaws such as out-of-plane wrinkles and fibre re-orientation. Forming methods often consist of automated processes in which flat composite blanks are forced to comply with tool geometries. Although Finite Element forming simulations require the modelling of all stakeholders (blankholder, tooling and composite blank), consumables such as separation films are often not considered. Used in thermoforming processes, these films are placed between tooling and composite to ease part removal after forming. These films are also used to decrease tool/ply friction and thus, enhance forming quality. This work presents thermoforming simulations of pre-impregnated carbon fibre thermoplastic blanks in which separation films are modelled in the same manner as composite layers, i.e. by a layer of shell elements. The mechanical properties of such films are also characterised at the same temperature as forming occurs. The proposed approach is finally compared to the actual modelling method, in which separation films are not modelled as such but in which their influence is only considered within the friction coefficient between tooling and blank.

Top